WorldWideScience

Sample records for control panel components

  1. Layout of 'hard' and 'soft' control panels

    International Nuclear Information System (INIS)

    Schulz, K.A.

    1984-01-01

    Large control panels, containing hundreds of indicators and controls, have long been used in process plants. The general arrangement of instruments on the panel should reflect ergonomic principles to help operators to quickly and accurately locate, identify and select controls and displays as they monitor and supervise plant systems and processes. For the multiplexed systems now displacing dedicated components, there is a corresponding set of design problems involving display-page formats and the design of display ensembles. A list of alternative organizing principles is presented, with particular emphasis on those based on plant function. Methodologies for selecting and applying the principles are discussed

  2. Ergonomic Redesign of an Industrial Control Panel

    Directory of Open Access Journals (Sweden)

    S Raeisi

    2016-07-01

    Full Text Available Operator's role in industrial control centers takes place in time, which is one of the most important determinants of whether an expected action is going to be successful or not. In certain situations, due to the complex nature of the work, the existing interfaces and already prepared procedures do not meet the dynamic requirements of operator's cognitive demands, making the control tasks unnecessarily difficult. This study was conducted to identify ergonomic issues with a specific industrial control panel, and redesign its layout and elements to enhance its usability. Task and link analysis methodologies were implemented. All essential functions and supporting operations were identified at the required trivial levels. Next, the weight of any possible link between the elements of the panel was computed as a composite index of frequency and importance. Finally, all components were rearranged within a new layout, and a computerized mockup was generated. A total of 8 primary tasks was identified, including 4 system failure handling tasks, switching between manual and automated modes, and 3 types of routine vigilance and control tasks. These tasks were broken down into 28 functions and 145 supporting operations, accordingly. Higher link values were observed between hand rest position and 2 elements. Also, 6 other components showed robust linkages. In conclusion, computer modeling can reduce the likelihood of accidents and near misses in industrial control rooms by considering the operators' misperception or mental burden and correcting poor design of the panels and inappropriate task allocation.

  3. Control panel for CMC 8080 crate controller

    International Nuclear Information System (INIS)

    Masayuki Inokuchi

    1978-01-01

    The main features of Control Panel for CAMAC Crate Controller CMC 8080 are described. The control panel can be directly connected with CRATE CONTROLLER's front panel connector with a 50 lines cable without any changes in CMC 8080 system circuits. (author)

  4. Cavity Control and Panel Control Strategies in Double-Panel Structures for Transmitted Noise Reduction

    NARCIS (Netherlands)

    Ho, J.; Kalverboer, J.; Berkhoff, Arthur P.

    2012-01-01

    Investigation and comparisons of the cavity control and the panel control in a double-panel structure are presented in this paper. The double-panel structure, which comprises two panels with air in the gap, provides the advantages of low sound-transmission at high frequency, low heat-transmission

  5. Panel Resonance Control and Cavity Control in Double-Panel Structures for Active Noise Reduction

    NARCIS (Netherlands)

    Ho, J.; Berkhoff, Arthur P.

    2011-01-01

    An analytical and experimental investigation of panel resonance control and cavity control in a double-panel structure is presented in this paper. The double-panel structure, which consists of two panels with air in the gap, is widely adopted in many applications such as aerospace due to its low

  6. JDDD, a state-of-the-art solution for control panel development

    International Nuclear Information System (INIS)

    Sombrowski, E.; Petrosyan, A.; Rehlich, K.; Schuette

    2012-01-01

    Software for graphical user interfaces to control systems may be developed as a rich or thin client. The thin client approach has the advantage that anyone can create and modify control system panels without specific skills in software programming. The Java DOOCS Data Display (JDDD) is based on the thin client interaction model. It provides inclusion of panel components and channel address inheritance for the creation of generic displays. Wildcard operations and regular expression filters are used to customize the graphics content at runtime, e.g. in a dynamic list component the parameters have to be painted only once in edit mode and then are automatically displayed multiple times for all available instances in run mode. This paper will describe the benefits of using JDDD for control panel design as an alternative to rich client development

  7. Plasma Facing Components Generic Facilities Review Panel (PFC-GFRP): Final report

    International Nuclear Information System (INIS)

    McGrath, R.; Allen, S.; Hill, D.; Brooks, J.; Mattas, R.; Davis, J.; Lipschultz, B.; Ulrickson, M.

    1993-10-01

    The Plasma Facing Components (PFC) Facilities Review Panel was chartered by the US Department of Energy, Office of Fusion Energy, ITER (International Thermonuclear Experimental Reactor) and Technology Division, to outline the program plan and identify the supporting test facilities that lead to reliable, long-lived plasma facing components for ITER. This report summarizes the panel's findings and identifies the necessary and sufficient set of test facilities required for ITER PFC development

  8. Noise Reduction in Double‿Panel Structures by Cavity and Panel Resonance Control

    OpenAIRE

    Ho, J.; Berkhoff, Arthur P.

    2011-01-01

    This paper presents an investigation of the cavity and the panel resonance control in a double‿panel structure. The double‿panel structure, which consists of two panels with air in the gap, is widely adopted in many applications such as aerospace due to its light weight and effective transmission‿loss at high frequency. However, the resonance of the cavity and the poor transmission‿loss at low frequency limit its noise control performance. Applying active control forces on the panels or utili...

  9. Noise Reduction in Double‿Panel Structures by Cavity and Panel Resonance Control

    NARCIS (Netherlands)

    Ho, J.; Berkhoff, Arthur P.

    2011-01-01

    This paper presents an investigation of the cavity and the panel resonance control in a double‿panel structure. The double‿panel structure, which consists of two panels with air in the gap, is widely adopted in many applications such as aerospace due to its light weight and effective

  10. Noise reduction in double-panel structures by cavity and panel resonance control

    NARCIS (Netherlands)

    Ho, J.-H.; Berkhoff, A.P

    2011-01-01

    This paper presents an investigation of the cavity and the panel resonance control in a double‐panel structure. The double‐panel structure, which consists of two panels with air in the gap, is widely adopted in many applications such as aerospace due to its light weight and effective

  11. Touch panel system for control applications

    International Nuclear Information System (INIS)

    Crook, K.; Johnson, R.

    1976-12-01

    The use of finger-sensitive touch panels in association with computer-generated displays for control and monitoring of the Stanford linear accelerator is discussed. This control concept has proven to be very effective. The hardware and software aspects of the Touch Panel portion of the control system are described

  12. Concentrating Solar Power Central Receiver Panel Component Fabrication and Testing FINAL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    McDowell, Michael W [Pratt & Whitney Rocketdyne; Miner, Kris [Pratt & Whitney Rocketdyne

    2013-03-30

    The objective of this project is to complete a design of an advanced concentrated solar panel and demonstrate the manufacturability of key components. Then confirm the operation of the key components under prototypic solar flux conditions. This work is an important step in reducing the levelized cost of energy (LCOE) from a central receiver solar power plant. The key technical risk to building larger power towers is building the larger receiver systems. Therefore, this proposed technology project includes the design of an advanced molten salt prototypic sub-scale receiver panel that can be utilized into a large receiver system. Then complete the fabrication and testing of key components of the receive design that will be used to validate the design. This project shall have a significant impact on solar thermal power plant design. Receiver panels of suitable size for utility scale plants are a key element to a solar power tower plant. Many subtle and complex manufacturing processes are involved in producing a reliable, robust receiver panel. Given the substantial size difference between receiver panels manufactured in the past and those needed for large plant designs, the manufacture and demonstration on prototype receiver panel components with representative features of a full-sized panel will be important to improving the build process for commercial success. Given the thermal flux limitations of the test facility, the panel components cannot be rendered full size. Significance changes occurred in the projects technical strategies from project initiation to the accomplishments described herein. The initial strategy was to define cost improvements for the receiver, design and build a scale prototype receiver and test, on sun, with a molten salt heat transport system. DOE had committed to constructing a molten salt heat transport loop to support receiver testing at the top of the NSTTF tower. Because of funding constraints this did not happen. A subsequent plan to

  13. Comparisons between various cavity and panel noise reduction control in double-panel structures

    NARCIS (Netherlands)

    Ho, J.H.; Kalverboer, J.; Berkhoff, A.P.

    2012-01-01

    This paper presents comparisons between various panel and cavity resonance control methods to reduce the transmitted sound in a double-panel structure. The double-panel, which consists of two panels with air in the gap, has the advantages of low weight and effective transmission-loss at high

  14. A GOMS model applied to a simplified control panel design

    International Nuclear Information System (INIS)

    Chavez, C.; Edwards, R.M.

    1992-01-01

    The design of the user interface for a new system requires many decisions to be considered. To develop sensitivity to user needs requires understanding user behavior. The how-to-do-it knowledge is a mixture of task-related and interface-related components. A conscientious analysis of these components, allows the designer to construct a model in terms of goals, operators, methods, and selection (GOMS model) rules that can be advantageously used in the design process and evaluation of a user interface. The emphasis of the present work is on describing the importance and use of a GOMS model as a formal user interface analysis tool in the development of a simplified panel for the control of a nuclear power plant. At Pennsylvania State University, a highly automated control system with a greatly simplified human interface has been proposed to improve power plant safety. Supervisory control is to be conducted with a simplified control panel with the following functions: startup, shutdown, increase power, decrease power, reset, and scram. Initial programming of the operator interface has been initiated within the framework of a U.S. Department of Energy funded university project for intelligent distributed control. A hypothesis to be tested is that this scheme can be also used to estimate mental work load content and predict human performance

  15. BWR plant advanced central control panel PODIA

    International Nuclear Information System (INIS)

    Fujii, K.; Hayakawa, H.; Ikeda, Y.; Neda, T.; Suto, O.; Takamiya, S.

    1983-01-01

    BWR plant central control panels have become more and more enlarged and complicated recently due to the magnification of the scale of a plant and the requirement to reinforce safety. So, it is important to make communication between men and the complicated central control panel smooth. Toshiba has developed an advanced central control panel, named PODIA, which uses many computers and color CRTs, and PODIA is now in the stage of application to practical plants. In this article, the writers first touch upon control functions transition in the central control room, the PODIA position concerning the world-wide trend in this technology phase and the human engineering on the design. Then they present concrete design concepts for the control board and computer system which constitute PODIA

  16. Identification of component performance degradations caused by ageing using expert panels

    International Nuclear Information System (INIS)

    Nitoi, Mirela; Cristea, Dumitru; Pavelescu, Margarit

    2008-01-01

    Since the component ageing can be considered as one of the important causes of operating events reported, the identification of ageing effects and implementation of appropriate methods for mitigation of these effects represent an important preoccupation of many organizations and research activities. In the process of identification of ageing manifestation we can use either analysis of operational data or expert opinions, each of the methods having specific advantages and disadvantages. A reasonable combination of statistical, structural reliability and expert panel methods would be an appropriate approach in the failure probability assessments. In case when there are not enough operational data, the expert judgments represent the only viable alternative in the effort dedicated to identification of components and systems vulnerability to ageing. The panel use judgments to analyse the degradation produced by ageing, to score the components based on specific criteria and to rank them relative to one another. The paper presents the approach developed, including evaluation criteria and assigning indices for assessment of particular types of ageing degradation (the case of secondary system of TRIGA reactor). (authors)

  17. Test-Anchored Vibration Response Predictions for an Acoustically Energized Curved Orthogrid Panel with Mounted Components

    Science.gov (United States)

    Frady, Gregory P.; Duvall, Lowery D.; Fulcher, Clay W. G.; Laverde, Bruce T.; Hunt, Ronald A.

    2011-01-01

    rich body of vibroacoustic test data was recently generated at Marshall Space Flight Center for component-loaded curved orthogrid panels typical of launch vehicle skin structures. The test data were used to anchor computational predictions of a variety of spatially distributed responses including acceleration, strain and component interface force. Transfer functions relating the responses to the input pressure field were generated from finite element based modal solutions and test-derived damping estimates. A diffuse acoustic field model was applied to correlate the measured input sound pressures across the energized panel. This application quantifies the ability to quickly and accurately predict a variety of responses to acoustically energized skin panels with mounted components. Favorable comparisons between the measured and predicted responses were established. The validated models were used to examine vibration response sensitivities to relevant modeling parameters such as pressure patch density, mesh density, weight of the mounted component and model form. Convergence metrics include spectral densities and cumulative root-mean squared (RMS) functions for acceleration, velocity, displacement, strain and interface force. Minimum frequencies for response convergence were established as well as recommendations for modeling techniques, particularly in the early stages of a component design when accurate structural vibration requirements are needed relatively quickly. The results were compared with long-established guidelines for modeling accuracy of component-loaded panels. A theoretical basis for the Response/Pressure Transfer Function (RPTF) approach provides insight into trends observed in the response predictions and confirmed in the test data. The software developed for the RPTF method allows easy replacement of the diffuse acoustic field with other pressure fields such as a turbulent boundary layer (TBL) model suitable for vehicle ascent. Structural responses

  18. Control panel handling of a nuclear simulator

    International Nuclear Information System (INIS)

    Martin Polo, F.; Jimenez Fraustro, L.A.; Banuelos Galindo, A.; Diamant Rubinstein, A.

    1985-01-01

    The handling of the control panels for a Nuclear Simulator for operating training is described. The control panels are handled by a set of intelligent controllers, each with at least two processors (8035 - Communications Controller and a 8085 - Master processor). The Controllers are connected to the main computers (Two dual processor Gould concept 32/6780 and a single processor Gould concept 32/6705) via serial asynchronous channels in a multidrop, star-like architecture. The controllers transmit to the main computers only the changes detected and receive the whole set of output variables as computed by the mathematical models of the Nuclear Plant

  19. Control room, emergency control system and local control panels in nuclear power plants

    International Nuclear Information System (INIS)

    1988-01-01

    The requirements on planning and construction of control boards including ergonomic-technical designing are specified in this rule. The specifications put the requirements on the design of place, process and environment of work, which are mentioned in the sections 90 and 91 of the labor-management relations act, into more concrete terms for the safety-relevant control panels as work places in a nuclear power station. The work places at control panels are not considered as video workstations in the sense of the 'Safety Rules for Video Workstations in the Office Sector' published by the General Association of the Industrial Trade Associations. The requirements are based on the operation and information technology realized at present in control panels of stationary nuclear power plants. (orig./HP) [de

  20. Active structural acoustic control of noise transmission through double panel systems

    Science.gov (United States)

    Carneal, James P.; Fuller, Chris R.

    1995-04-01

    A preliminary parametric study of active control of sound transmission through double panel systems has been experimentally performed. The technique used is the active structural acoustic control (ASAC) approach where control inputs, in the form of piezoelectric actuators, were applied to the structure while the radiated pressure field was minimized. Results indicate the application of control inputs to the radiating panel resulted in greater transmission loss due to its direct effect on the nature of the structural-acoustic coupling between the radiating panel and the receiving chamber. Increased control performance was seen in a double panel system consisting of a stiffer radiating panel with a lower modal density. As expected, more effective control of a radiating panel excited on-resonance is achieved over one excited off-resonance. In general, the results validate the ASAC approach for double panel systems and demonstrate that it is possible to take advantage of double panel behavior to enhance control performance, although it is clear that further research must be done to understand the physics involved.

  1. Virtual panel for FOTIA control and information system

    International Nuclear Information System (INIS)

    Singh, S.K.; Kansara, M.J.; Padmini, S.; Ananthakrishnan, T.S.; Ghodgaonkar, M.D.

    2001-01-01

    Use of computers has provided an easy environment to tune machines like accelerators by integrating different subsystems and providing interface to control whole machine from a single node. Use of virtual panel in place of conventional shaft encoders and hard wired controls has provided an easy and efficient and interactive environment for accelerator operation. A graphical user interface is provided for system configuration (system data base change). FOTIA (Folded Tandem Ion Accelerator) is an indigenously designed accelerator at BARC. This paper describes the Virtual Panel features of the FOTIA Control and Information System. (author)

  2. OLED Luminaire with Panel Integrated Drivers and Advanced Controls

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Michael [Acuity Brands Lighting, Inc., Atlanta, GA (United States); Spindler, Jeff [OLEDWorks, Rochester, NY (United States)

    2017-01-31

    For this DOE award, Acuity Brands Lighting developed a novel OLED luminaire system featuring panel-integrated drivers at each individual OLED panel. The luminaire has a base station that receives user commands and performs AC/DC conversion. A power line communication (PLC) protocol is used to provide both power and digital control to each panel. A 66-panel CanvisTM luminaire using state-of-art OLED panels based on this system was successfully constructed. This is a first demonstration of such a luminaire architecture. It is also the first known implementation of this number of independently addressable nodes with a PLC protocol. This luminaire system architecture has added benefits in the flexibility of using multiple panel vendors for a given product, forward compatibility with future panels, and reduced luminaire wiring complexity and assembly time.

  3. Ergonomic evaluation of CRT display in new control panels for nuclear power stations

    International Nuclear Information System (INIS)

    Kabazawa, Yoshihiko

    1983-01-01

    New control panels are to support powerfully the synthetic judgement function of operators by processing enormous plant data in the normal operation and at the time of accidents in nuclear power stations, and displaying the results in collective and ordered form on CRTs. This time, by carrying out the evaluation of new control panels using human engineering method, it was able to be confirmed that the new control panels have achieved the initial objectives, and to determine the criteria for the ergonomic evaluation of central control panels mainly with CRT display. Besides, it is considered that the application to wide range can be expected for this evaluation, not only to the CRT display system of the new control panels for nuclear power stations but also to other CRT images, therefore, the outline is reported. Chubu Electric Power Co., Inc. plans to adopt the new control panels with CRT display effectively utilizing process computers hereafter. It is necessary to give sufficient consideration to the method of using CRT images, the kinds of displayed images, colors and the form and arrangement of letters and symbols. 12 CRTs are used for the new control panel. The results are reflected to the control panel for Hamaoka No.3 plant. (Kako, I.)

  4. Questionable diagnostic benefit of the commercially available panel of bee venom components.

    Science.gov (United States)

    Arzt, L; Bokanovic, D; Schrautzer, C; Schwarz, I; Laipold, K; Aberer, W; Sturm, G J

    2017-09-01

    For many years, only the major allergen rApi m 1 has been available on the ImmunoCAP system for routine diagnosis of bee venom (BV) allergy. Now, there are five components available, and we aimed to detect the sensitivity and specificity of rApi m 1, 2, 3, 5, and 10 in BV-allergic patients. We further evaluated the sensitivity of rApi m 1 and 2 of an alternative platform and investigated possible differences in the sensitization profile between monosensitization and clinically relevant double sensitization. Analysis of the whole panel of BV allergens of the CAP system still resulted in a lower sensitivity than analysis of the combination of rApi m 1 and 2 of the Immulite (71.6% vs 85.8%). Sensitization rate of rApi m 5 was more than doubled in double-sensitized patients, while there was no difference for rApi m 2. The benefit of the commercially available panel of BV components is questionable, due to the insufficient sensitivity and still unavailable important cross-reacting allergens. © 2017 EAACI and John Wiley and Sons A/S. Published by John Wiley and Sons Ltd.

  5. Concept of Advanced Back-up Control Panel Design of Digital Main Control Room

    International Nuclear Information System (INIS)

    Jiang, Guo Jin; Sun, Yong Bin; Tan, Ke; Zhang, Li Ming; Shi, Ji; Zhang, Xue Gang; Huang, Wei Jun; Mao, Ting; Liu Yanzi

    2011-01-01

    Back-up control panel (BCP) of digital main control room (DMCR) is the backup means for main computerized control means (MCM). This paper focus on technical issues for advanced design of Backup Panel (BCP) for CPR1000 using qualified computer-based video display unit to display plant process indication and alarms. HFE issues also have been considered in the BCP design. Then, mean to fulfill safety target of NPP, best ergonomic effect has been described. At last conclusion on advanced BCP design is provided

  6. Concept of Advanced Back-up Control Panel Design of Digital Main Control Room

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Guo Jin; Sun, Yong Bin; Tan, Ke; Zhang, Li Ming; Shi, Ji; Zhang, Xue Gang; Huang, Wei Jun; Mao, Ting; Liu Yanzi [China Nuclear Power Engineering Company, Shenzen (China)

    2011-08-15

    Back-up control panel (BCP) of digital main control room (DMCR) is the backup means for main computerized control means (MCM). This paper focus on technical issues for advanced design of Backup Panel (BCP) for CPR1000 using qualified computer-based video display unit to display plant process indication and alarms. HFE issues also have been considered in the BCP design. Then, mean to fulfill safety target of NPP, best ergonomic effect has been described. At last conclusion on advanced BCP design is provided.

  7. A New MPPT Control for Photovoltaic Panels by Instantaneous Maximum Power Point Tracking

    Science.gov (United States)

    Tokushima, Daiki; Uchida, Masato; Kanbei, Satoshi; Ishikawa, Hiroki; Naitoh, Haruo

    This paper presents a new maximum power point tracking control for photovoltaic (PV) panels. The control can be categorized into the Perturb and Observe (P & O) method. It utilizes instantaneous voltage ripples at PV panel output terminals caused by the switching of a chopper connected to the panel in order to identify the direction for the maximum power point (MPP). The tracking for the MPP is achieved by a feedback control of the average terminal voltage of the panel. Appropriate use of the instantaneous and the average values of the PV voltage for the separate purposes enables both the quick transient response and the good convergence with almost no ripples simultaneously. The tracking capability is verified experimentally with a 2.8 W PV panel under a controlled experimental setup. A numerical comparison with a conventional P & O confirms that the proposed control extracts much more power from the PV panel.

  8. Design and construction of program frame software of 300 keV/20 mA EBM control panel computerized base

    International Nuclear Information System (INIS)

    Eko Priyono; Saminto

    2015-01-01

    The program frame software of computer based control panel for 300 keV/20 mA EBM has been designed and constructed. This software is used for EBM components operating system, EBM operating parameters monitor and control system. This software contain instructions program for acquisition, actuation, process and display operation parameters data which is made by using visual basic V.6. This software displays some menus i.e. cover menu, main menu, sub menu and sub-sub menu. Performance test was done by integrating software and hardware and then operated the EBM via computer device. The test show that data communication between software and hardware was suitable, EBM components can be operated via computer device, EMB operation parameters can be controlled and monitored in form digital number, bar graph and continuous graphics the device can execute properly all instruction output program of 300 keV/20 mA control panel so the device is ready to use as one of computerize operating system of 300 keV/20 mA. (author)

  9. Ergonomic design of mosaic control panel and standardised control tile configurations for 500 MWe PHWR

    International Nuclear Information System (INIS)

    Ughade, A.V.; Das, R.N.; Ramakrishnan, S.

    1994-01-01

    A review of control rooms of operating nuclear power plants identified many design problems having potential for degrading the performance of operators. Many indications and controls on existing control panels are placed outside the recommended visual and reach envelopes for acceptable operator usage. As a result, the application of human factor principles was found to be needed. This paper describes the design approach for working out the dimensions of main control room panels and console using human engineering principles and recommends the ergonomic dimensions of the main control room panels and console. Further it gives the basis and works out the control tile configurations for 500 MWe PHWR project. It also suggests the use of a full scale mock up for design evaluation and verification. (author). 7 refs., 4 figs

  10. Effectiveness of a large mimic panel in an existing nuclear power plant central control board

    International Nuclear Information System (INIS)

    Kubota, Ryuji; Satoh, Hiroyuki; Sasajima, Katsuhiro; Kawano, Ryutaro; Shibuya Shinya

    1999-01-01

    We conducted the analysis of the nuclear power plant (NPP) operators' behaviors under emergency conditions by using training simulators as a joint research project by Japanese BWR groups for twelve years. In the phase-IV of this project we executed two kinds of experiments to evaluate the effectiveness of the interfaces. One was for evaluations of the interfaces such as CRTs with touch screen, a large mimic panel, and a hierarchical annunciator system introduced in the newly developed ABWR type central control board. The other was that we analyzed the operators' behaviors in emergency conditions by using the first generation BWR type central control board which was added new interfaces such as a large display screen and demarcation on the board to help operators to understand the plant. The demarcation is one of the visual interface improvements and its technique is that a line enclosing several components causes them to be perceived as a group.The result showed that both the large display panel Introduced in ABWR central control board and the large display screen in the existing BWR type central control board improved the performance of the NPP operators in the experiments. It was expected that introduction of the large mimic panel into the existing BWR type central control boards would improve operators' performance. However, in the case of actual installation of the large display board into the existing central control boards, there are spatial and hardware constraints. Therefore the size of lamps, lines connecting from symbols of the pumps or valves to the others' will have to be modified under these constraints. It is important to evaluate the displayed information on the large display board before actual installation. We made experiments to solve these problems by using TEPCO's research simulator which is added a large mimic panel. (author)

  11. A virtual control panel configuration tool for the X-Window system

    International Nuclear Information System (INIS)

    Hill, J.O.; Dalesio, L.R.; Kerstiens, D.M.

    1992-01-01

    Computer Graphics Workstations are becoming increasingly popular for use as virtual process control and read back panels. The workstation's CRT, keyboard, and pointing device are used in concert to produce a display that is in essence a control panel, even if actual switches and gauges are not present. The code behind these displays is most often specific to one display and not reusable for any other display. Recently, programs have been written allowing many of these virtual control panel displays to be configured without writing additional code. This approach allows the initial programming effort to be reapplied to many different display instances with minimal effort. These programs often incorporate many of the features of a graphics editor, allowing a pictorial model of the process under control to be incorporated into the control panel. We have just finished writing a second generation software system of this type for use with the X-window system and the Experimental Physics and Industrial Control System (EPICS). This paper describes the primary features of our software, the framework of our design, and our observations after initial installation. (author)

  12. An Exemplary Case of Promotion Activities and Taste Panels from the Perspective of Tobacco Control

    Science.gov (United States)

    Mutlu, Erdem İlker; Seydioğulları, Mustafa; Aslan, Dilek

    2015-01-01

    The Framework Convention on Tobacco Control is a multilateral international agreement which has been generated to protect the health of nationals and nations against the hazards/risks of tobacco and its products. All high contracting parties to the Convention undertake the international responsibility to fulfill all the requirements of the Convention’s articles in national legal systems. The Framework Convention on Tobacco Control has a considerable place among other international conventions on health. Within the self-executing desing/system of the Convention, a vital regulation focuses on banning the advertisement, promotion, and sponsorship of tobacco products. Because they are one of the various components of tobacco advertisement, promotion, and sponsorship, taste panels should be assessed within the content of the Convention. Thus, banning taste panel activities is an important step in tobacco control and it is one of the basic areas where medical and law sciences should collaborate. In this article, a comprehensive frame has been drawn to the issue and recommendations have been developed for the future. PMID:29404102

  13. Man-machine enhancements to existing FFTF control panels

    International Nuclear Information System (INIS)

    Miller, E.M.

    1984-01-01

    FFTF Project enhanced existing control panels with tape and labels to mitigate operator problems and to incorporate the guidance of NUREG-0700. The enhancements grouped displays and controls into meaningful units and labelled controls and displays to facilitate their identification and efficient use. The enhancements were inexpensive and well received by the facility's operations staff

  14. Active control of turbulent boundary layer-induced sound transmission through the cavity-backed double panels

    Science.gov (United States)

    Caiazzo, A.; Alujević, N.; Pluymers, B.; Desmet, W.

    2018-05-01

    This paper presents a theoretical study of active control of turbulent boundary layer (TBL) induced sound transmission through the cavity-backed double panels. The aerodynamic model used is based on the Corcos wall pressure distribution. The structural-acoustic model encompasses a source panel (skin panel), coupled through an acoustic cavity to the radiating panel (trim panel). The radiating panel is backed by a larger acoustic enclosure (the back cavity). A feedback control unit is located inside the acoustic cavity between the two panels. It consists of a control force actuator and a sensor mounted at the actuator footprint on the radiating panel. The control actuator can react off the source panel. It is driven by an amplified velocity signal measured by the sensor. A fully coupled analytical structural-acoustic model is developed to study the effects of the active control on the sound transmission into the back cavity. The stability and performance of the active control system are firstly studied on a reduced order model. In the reduced order model only two fundamental modes of the fully coupled system are assumed. Secondly, a full order model is considered with a number of modes large enough to yield accurate simulation results up to 1000 Hz. It is shown that convincing reductions of the TBL-induced vibrations of the radiating panel and the sound pressure inside the back cavity can be expected. The reductions are more pronounced for a certain class of systems, which is characterised by the fundamental natural frequency of the skin panel larger than the fundamental natural frequency of the trim panel.

  15. Re-Active Passive devices for control of noise transmission through a panel

    Science.gov (United States)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Dan

    2008-01-01

    Re-Active Passive devices have been developed to control low-frequency (transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The Re-Active Passive device uses passive constrained layer damping to cover relatively high-frequency range (>150 Hz), reactive distributed vibration absorber to cover the medium-frequency range (50-200 Hz), and active control for controlling low frequencies (transmission through a panel mounted in the Transmission Loss Test Facility at Virginia Tech. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three Re-Active Passive devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 g to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  16. Control source development for reduction of noise transmitted through a double panel structure

    OpenAIRE

    Ho, J.

    2014-01-01

    A double panel structure, which consists of two panels with air in between, is widely adopted in many applications such as aerospace, automotive industries, and buildings due to its low sound transmission at high frequencies, low heat transmission, and low weight. Nevertheless, the resonance of the cavity and the poor sound transmission loss at low frequencies limit the double panel’s noise control performance. Applying active structural acoustic control to the panels or active noise control ...

  17. Evaluation of voice control, touch panel control and assistant control during steering of an endoscope

    NARCIS (Netherlands)

    Punt, Marius M.; Stefels, Coen N.; Grimbergen, Cornelis A.; Dankelman, Jenny

    2005-01-01

    The increasing amount of equipment used in the Operating Room ( OR) asks for ergonomical user interfaces. The aim of this study was to investigate in a pelvi-trainer setting the efficiency, reliability and user satisfaction of voice control, touch panel control and conventional manual control by an

  18. Hybrid Active/Passive Control of Sound Radiation from Panels with Constrained Layer Damping and Model Predictive Feedback Control

    Science.gov (United States)

    Cabell, Randolph H.; Gibbs, Gary P.

    2000-01-01

    There has been considerable interest over the past several years in applying feedback control methods to problems of structural acoustics. One problem of particular interest is the control of sound radiation from aircraft panels excited on one side by a turbulent boundary layer (TBL). TBL excitation appears as many uncorrelated sources acting on the panel, which makes it difficult to find a single reference signal that is coherent with the excitation. Feedback methods have no need for a reference signal, and are thus suited to this problem. Some important considerations for the structural acoustics problem include the fact that the required controller bandwidth can easily extend to several hundred Hertz, so a digital controller would have to operate at a few kilohertz. In addition, aircraft panel structures have a reasonably high modal density over this frequency range. A model based controller must therefore handle the modally dense system, or have some way to reduce the bandwidth of the problem. Further complicating the problem is the fact that the stiffness and dynamic properties of an aircraft panel can vary considerably during flight due to altitude changes resulting in significant resonant frequency shifts. These considerations make the tradeoff between robustness to changes in the system being controlled and controller performance especially important. Recent papers concerning the design and implementation of robust controllers for structural acoustic problems highlight the need to consider both performance and robustness when designing the controller. While robust control methods such as H1 can be used to balance performance and robustness, their implementation is not easy and requires assumptions about the types of uncertainties in the plant being controlled. Achieving a useful controller design may require many tradeoff studies of different types of parametric uncertainties in the system. Another approach to achieving robustness to plant changes is to

  19. Robust control investigations for equipment loaded panels

    DEFF Research Database (Denmark)

    Aglietti, G.S.; Langley, R.S.; Rogers, E.

    1998-01-01

    This paper develops a modelling technique for equipment load panels which directly produces (adequate) models of the underlying dynamics on which to base robust controller design/evaluations. This technique is based on the use of the Lagrange's equations of motion and the resulting models...

  20. WTEC panel report on European nuclear instrumentation and controls

    International Nuclear Information System (INIS)

    White, J.D.; Lanning, D.D.; Johnson, P.M.H.

    1991-12-01

    A study of instrumentation and controls (I and C) technology used in nuclear power plants in Europe was conducted by a panel of US specialists. This study plants in Europe was conducted by a panel of US specialists. This study included a review of the literature on the subject, followed by a visit to some of the leading organizations in Europe in the field nuclear I and C. Areas covered are: (1) role of the operator and control room design; (2) transition from analog to digital technology; (3) computerized operator support systems for fault management; (4) control strategies and techniques; (5) Nuclear power plant I and C architecture; (6) instrumentation and (7) computer standards and tools. The finding relate to poor reactions

  1. Re-active Passive (RAP) Devices for Control of Noise Transmission through a Panel

    Science.gov (United States)

    Carneal, James P.; Giovanardi, Marco; Fuller, Chris R.; Palumbo, Daniel L.

    2008-01-01

    Re-Active Passive (RAP) devices have been developed to control low frequency (transmission through a panel. These devices use a combination of active, re-active, and passive technologies packaged into a single unit to control a broad frequency range utilizing the strength of each technology over its best suited frequency range. The RAP device uses passive constrained layer damping to cover the relatively high frequency range (>200 Hz), reactive distributed vibration absorber) to cover the medium frequency range (75 to 250 Hz), and active control for controlling low frequencies (transmission through a panel mounted in a transmission loss test facility. Experimental results are presented for the bare panel, and combinations of passive treatment, reactive treatment, and active control. Results indicate that three RAP devices were able to increase the overall broadband (15-1000 Hz) transmission loss by 9.4 dB. These three devices added a total of 285 grams to the panel mass of 6.0 kg, or approximately 5%, not including control electronics.

  2. Automated Intelligent Monitoring and the Controlling Software System for Solar Panels

    Science.gov (United States)

    Nalamwar, H. S.; Ivanov, M. A.; Baidali, S. A.

    2017-01-01

    The inspection of the solar panels on a periodic basis is important to improve longevity and ensure performance of the solar system. To get the most solar potential of the photovoltaic (PV) system is possible through an intelligent monitoring & controlling system. The monitoring & controlling system has rapidly increased its popularity because of its user-friendly graphical interface for data acquisition, monitoring, controlling and measurements. In order to monitor the performance of the system especially for renewable energy source application such as solar photovoltaic (PV), data-acquisition systems had been used to collect all the data regarding the installed system. In this paper the development of a smart automated monitoring & controlling system for the solar panel is described, the core idea is based on IoT (the Internet of Things). The measurements of data are made using sensors, block management data acquisition modules, and a software system. Then, all the real-time data collection of the electrical output parameters of the PV plant such as voltage, current and generated electricity is displayed and stored in the block management. The proposed system is smart enough to make suggestions if the panel is not working properly, to display errors, to remind about maintenance of the system through email or SMS, and to rotate panels according to a sun position using the Ephemeral table that stored in the system. The advantages of the system are the performance of the solar panel system which can be monitored and analyzed.

  3. Active control of sound transmission through a double panel partition

    Science.gov (United States)

    Sas, P.; Bao, C.; Augusztinovicz, F.; Desmet, W.

    1995-03-01

    The feasibility of improving the insertion loss of lightweight double panel partitions by using small loudspeakers as active noise control sources inside the air gap between both panels of the partition is investigated analytically, numerically and experimentally in this paper. A theoretical analysis of the mechanisms of the fluid-structure interaction of double panel structures is presented in order to gain insight into the physical phenomena underlying the behaviour of a coupled vibro-acoustic system controlled by active methods. The analysis, based on modal coupling theory, enables one to derive some qualitative predictions concerning the potentials and limitations of the proposed approach. The theoretical analysis is valid only for geometrically simple structures. For more complex geometries, numerical simulations are required. Therefore the potential use of active noise control inside double panel structures has been analyzed by using coupled finite element and boundary element methods. To verify the conclusions drawn from the theoretical analysis and the numerical calculation and, above all, to demonstrate the potential of the proposed approach, experiments have been conducted with a laboratory set-up. The performance of the proposed approach was evaluated in terms of relative insertion loss measurements. It is shown that a considerable improvement of the insertion loss has been achieved around the lightly damped resonances of the system for the frequency range investigated (60-220 Hz).

  4. Control component retainer

    International Nuclear Information System (INIS)

    Walton, L.A.; King, R.A.

    1983-01-01

    An apparatus is described for retaining an undriven control component assembly disposed in a fuel assembly in a nuclear reactor of the type having a core grid plate. The first part of the mechanism involves a housing for the control component and the second part is a brace with a number of arms that reach under the grid plate. The brace and the housing are coupled together to firmly hold the control components in place even under strong flows of th coolant

  5. Dual-mode switching of a liquid crystal panel for viewing angle control

    Science.gov (United States)

    Baek, Jong-In; Kwon, Yong-Hoan; Kim, Jae Chang; Yoon, Tae-Hoon

    2007-03-01

    The authors propose a method to control the viewing angle of a liquid crystal (LC) panel using dual-mode switching. To realize both wide viewing angle (WVA) characteristics and narrow viewing angle (NVA) characteristics with a single LC panel, the authors use two different dark states. The LC layer can be aligned homogeneously parallel to the transmission axis of the bottom polarizer for WVA dark state operation, while it can be aligned vertically for NVA dark state operation. The authors demonstrated that viewing angle control can be achieved with a single panel without any loss of contrast at the front.

  6. El Salvador - Rural Electrification - Solar Panels

    Data.gov (United States)

    Millennium Challenge Corporation — This is a summative qualitative performance evaluation (PE) of the solar panel component of the solar panel component of the RE Sub-Activity. The final report will...

  7. Use of informatics in radiation control panels

    International Nuclear Information System (INIS)

    Cochinal, R.; Grimont, B.; Mai, V.

    1980-03-01

    Radiation control panels with programmed systems have developed at the CEA over the last few years. Each monitored location is provided with an monitoring station containing: - a radiation detector and associated electronics (the output signal is normalised calibrated pulses), - an alarm unit to warn personnal of any danger inside the detection zone covered [fr

  8. An analytical and experimental investigation of active structural acoustic control of noise transmission through double panel systems

    Science.gov (United States)

    Carneal, James P.; Fuller, Chris R.

    2004-05-01

    An analytical and experimental investigation of active control of sound transmission through double panel systems has been performed. The technique used was active structural acoustic control (ASAC) where the control inputs, in the form of piezoelectric actuators, were applied to the structure while the radiating pressure field was minimized. Results verify earlier experimental investigations and indicate the application of control inputs to the radiating panel of the double panel system resulted in greater transmission loss (TL) due to its direct effect on the nature of the structural-acoustic (or radiation) coupling between the radiating panel and the receiving acoustic space. Increased control performance was seen in a double panel system consisting of a stiffer radiating panel due to its lower modal density and also as a result of better impedance matching between the piezoelectric actuator and the radiating plate. In general the results validate the ASAC approach for double panel systems, demonstrating that it is possible to take advantage of double panel system passive behavior to enhance control performance, and provide design guidelines.

  9. Active sound transmission control of an experimental double-panel partition using decoupled, dual-channel, analog feedback control

    OpenAIRE

    Sagers, Jason; Blotter, Jonathan

    2008-01-01

    This paper addresses the construction, measurement, and analysis of a double panel active partition (DPAP) and its accompanying analog feedback controllers. The DPAP was constructed by attaching an aluminum cone loudspeaker at each end of a short segment of a circular duct. Two analog feedback controllers were designed and built using the measured frequency response function of each panel. Two independent (decoupled) feedback controllers were then used to minimize the vibration amplitude of e...

  10. Anthropometric Considerations in the Modernized Main Control Room: Application to a Virtual Nuclear Power Plant Control Panel

    International Nuclear Information System (INIS)

    Yang, Chih Wei; Cheng, Tsung Chieh; Lin, Chiuhsiang Joe

    2011-01-01

    This study investigates the anthropometric considerations in the main control room (MCR) application to a virtual nuclear power plant (NPP) control panel. Influences of working postures and physical demands on the operational performance are also discussed. Finally, the present research provides a case example to illustrate the influences of anthropometric considerations on the control panel design for MCR operators by applying virtual reality (VR) technology. The MCR design primarily evolved in different countries. The datasets available is usually insufficient or inconsistent for the end users. To solve the upper mentioned problem, this study put emphasis on applying VR technology to anthropometric considerations support control panel design in the modernized MCR. Although the concept of applying VR technology on anthropometric considerations in this paper is related to the MCR in NPPs, it could be easily applied for the purposes of any type of control room in a similar manner

  11. Anthropometric Considerations in the Modernized Main Control Room: Application to a Virtual Nuclear Power Plant Control Panel

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chih Wei; Cheng, Tsung Chieh [Institute of Nuclear Energy Research, Taoyuan (China); Lin, Chiuhsiang Joe [Chung-Yuan Christian University, Chung Li (China)

    2011-08-15

    This study investigates the anthropometric considerations in the main control room (MCR) application to a virtual nuclear power plant (NPP) control panel. Influences of working postures and physical demands on the operational performance are also discussed. Finally, the present research provides a case example to illustrate the influences of anthropometric considerations on the control panel design for MCR operators by applying virtual reality (VR) technology. The MCR design primarily evolved in different countries. The datasets available is usually insufficient or inconsistent for the end users. To solve the upper mentioned problem, this study put emphasis on applying VR technology to anthropometric considerations support control panel design in the modernized MCR. Although the concept of applying VR technology on anthropometric considerations in this paper is related to the MCR in NPPs, it could be easily applied for the purposes of any type of control room in a similar manner.

  12. Modeling and Control of the Redundant Parallel Adjustment Mechanism on a Deployable Antenna Panel

    Directory of Open Access Journals (Sweden)

    Lili Tian

    2016-10-01

    Full Text Available With the aim of developing multiple input and multiple output (MIMO coupling systems with a redundant parallel adjustment mechanism on the deployable antenna panel, a structural control integrated design methodology is proposed in this paper. Firstly, the modal information from the finite element model of the structure of the antenna panel is extracted, and then the mathematical model is established with the Hamilton principle; Secondly, the discrete Linear Quadratic Regulator (LQR controller is added to the model in order to control the actuators and adjust the shape of the panel. Finally, the engineering practicality of the modeling and control method based on finite element analysis simulation is verified.

  13. Application of a Broadband Active Vibration Control System to a Helicopter Trim Panel

    Science.gov (United States)

    Cabell, Randolph H.; Schiller, Noah H.; Simon, Frank

    2013-01-01

    This paper discusses testing of a broadband active vibration control concept on an interior trim panel in a helicopter cabin mockup located at ONERA's Centre de Toulouse. The control system consisted of twelve diamond-shaped piezoelectric actuators distributed around a 1.2m x 1.2m trim panel. Accelerometers were mounted at the four vertices of each diamond. The aspect ratio of the diamond was based on the dielectric constants of the piezoelectric material in order to create an actuator-sensor pair that was collocated over a broad frequency range. This allowed robust control to be implemented using simple, low power analog electronics. Initial testing on a thick acrylic window demonstrated the capability of the controller, but actuator performance was less satisfactory when mounted on a composite sandwich trim panel. This may have been due to the orthotropic nature of the trim panel, or due to its much higher stiffness relative to the acrylic window. Insights gained from a finite element study of the actuator-sensor-structural system are discussed.

  14. Results of molten salt panel and component experiments for solar central receivers: Cold fill, freeze/thaw, thermal cycling and shock, and instrumentation tests

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, J.E.; Ralph, M.E.; Chavez, J.M.; Dunkin, S.R.; Rush, E.E.; Ghanbari, C.M.; Matthews, M.W.

    1995-01-01

    Experiments have been conducted with a molten salt loop at Sandia National Laboratories in Albuquerque, NM to resolve issues associated with the operation of the 10MW{sub e} Solar Two Central Receiver Power Plant located near Barstow, CA. The salt loop contained two receiver panels, components such as flanges and a check valve, vortex shedding and ultrasonic flow meters, and an impedance pressure transducer. Tests were conducted on procedures for filling and thawing a panel, and assessing components and instrumentation in a molten salt environment. Four categories of experiments were conducted: (1) cold filling procedures, (2) freeze/thaw procedures, (3) component tests, and (4) instrumentation tests. Cold-panel and -piping fill experiments are described, in which the panels and piping were preheated to temperatures below the salt freezing point prior to initiating flow, to determine the feasibility of cold filling the receiver and piping. The transient thermal response was measured, and heat transfer coefficients and transient stresses were calculated from the data. Freeze/thaw experiments were conducted with the panels, in which the salt was intentionally allowed to freeze in the receiver tubes, then thawed with heliostat beams. Slow thermal cycling tests were conducted to measure both how well various designs of flanges (e.g., tapered flanges or clamp type flanges) hold a seal under thermal conditions typical of nightly shut down, and the practicality of using these flanges on high maintenance components. In addition, the flanges were thermally shocked to simulate cold starting the system. Instrumentation such as vortex shedding and ultrasonic flow meters were tested alongside each other, and compared with flow measurements from calibration tanks in the flow loop.

  15. Micro-inverter solar panel mounting

    Science.gov (United States)

    Morris, John; Gilchrist, Phillip Charles

    2016-02-02

    Processes, systems, devices, and articles of manufacture are provided. Each may include adapting micro-inverters initially configured for frame-mounting to mounting on a frameless solar panel. This securement may include using an adaptive clamp or several adaptive clamps secured to a micro-inverter or its components, and using compressive forces applied directly to the solar panel to secure the adaptive clamp and the components to the solar panel. The clamps can also include compressive spacers and safeties for managing the compressive forces exerted on the solar panels. Friction zones may also be used for managing slipping between the clamp and the solar panel during or after installation. Adjustments to the clamps may be carried out through various means and by changing the physical size of the clamps themselves.

  16. Equipment, components and production of x-ray

    International Nuclear Information System (INIS)

    Idris Besar

    2004-01-01

    The contents of this chapter are follows - Equipment, Components and Production of x-Ray: x-ray system, generator, control panel. x-ray tube, cathode, anode, envelope, housing, collimator, other components, x-ray production, Bremsstrahlung x-ray, characteristic x-ray, heat production

  17. Comparison of various decentralised structural and cavity feedback control strategies for transmitted noise reduction through a double panel structure

    Science.gov (United States)

    Ho, Jen-Hsuan; Berkhoff, Arthur

    2014-03-01

    This paper compares various decentralised control strategies, including structural and acoustic actuator-sensor configuration designs, to reduce noise transmission through a double panel structure. The comparison is based on identical control stability indexes. The double panel structure consists of two panels with air in between and offers the advantages of low sound transmission at high frequencies, low heat transmission, and low weight. The double panel structure is widely used, such as in the aerospace and automotive industries. Nevertheless, the resonance of the cavity and the poor sound transmission loss at low frequencies limit the double panel's noise control performance. Applying active structural acoustic control to the panels or active noise control to the cavity has been discussed in many papers. In this paper, the resonances of the panels and the cavity are considered simultaneously to further reduce the transmitted noise through an existing double panel structure. A structural-acoustic coupled model is developed to investigate and compare various structural control and cavity control methods. Numerical analysis and real-time control results show that structural control should be applied to both panels. Three types of cavity control sources are presented and compared. The results indicate that the largest noise reduction is obtained with cavity control by loudspeakers modified to operate as incident pressure sources.

  18. Diagnosis of the Main Busbar II Panel Components Ageing of RSG-GAS Electrical System by Using Infrared Thermography

    International Nuclear Information System (INIS)

    Teguh Sulistyo; Kiswanto; Roziq Himawan; Ari Satmoko

    2007-01-01

    To support the operation of RSG-GAS safely, the diagnosis of the ageing of main busbar II BHD/BHE/BHF panel components of RSG-GAS electrical system have been done. By using infrared thermography type Thermo Tracer TH9100PM VI/PW VI. The results of the diagnosis showed that some of the components under degradation with various rate. It can cause the system failure. By understanding the components ageing degradation mechanism and performing the preventive and predictive maintenance and safety of RSG-GAS electrical system earlier, the possibility of accident can be avoided. (author)

  19. Component Control System for a Vehicle

    Science.gov (United States)

    Fraser-Chanpong, Nathan (Inventor); Spain, Ivan (Inventor); Dawson, Andrew D. (Inventor); Bluethmann, William J. (Inventor); Lee, Chunhao J. (Inventor); Vitale, Robert L. (Inventor); Guo, Raymond (Inventor); Waligora, Thomas M. (Inventor); Akinyode, Akinjide Akinniyi (Inventor); Reed, Ryan M. (Inventor)

    2016-01-01

    A vehicle includes a chassis, a modular component, and a central operating system. The modular component is supported by the chassis. The central operating system includes a component control system, a primary master controller, and a secondary master controller. The component control system is configured for controlling the modular component. The primary and secondary master controllers are in operative communication with the component control system. The primary and secondary master controllers are configured to simultaneously transmit commands to the component control system. The component control system is configured to accept commands from the secondary master controller only when a fault occurs in the primary master controller.

  20. Optimal placement and decentralized robust vibration control for spacecraft smart solar panel structures

    International Nuclear Information System (INIS)

    Jiang, Jian-ping; Li, Dong-xu

    2010-01-01

    The decentralized robust vibration control with collocated piezoelectric actuator and strain sensor pairs is considered in this paper for spacecraft solar panel structures. Each actuator is driven individually by the output of the corresponding sensor so that only local feedback control is implemented, with each actuator, sensor and controller operating independently. Firstly, an optimal placement method for the location of the collocated piezoelectric actuator and strain gauge sensor pairs is developed based on the degree of observability and controllability indices for solar panel structures. Secondly, a decentralized robust H ∞ controller is designed to suppress the vibration induced by external disturbance. Finally, a numerical comparison between centralized and decentralized control systems is performed in order to investigate their effectiveness to suppress vibration of the smart solar panel. The simulation results show that the vibration can be significantly suppressed with permitted actuator voltages by the controllers. The decentralized control system almost has the same disturbance attenuation level as the centralized control system with a bit higher control voltages. More importantly, the decentralized controller composed of four three-order systems is a better practical implementation than a high-order centralized controller is

  1. Causal feedforward control of a stochastically excited fuselage structure with active sidewall panel.

    Science.gov (United States)

    Misol, Malte; Haase, Thomas; Monner, Hans Peter; Sinapius, Michael

    2014-10-01

    This paper provides experimental results of an aircraft-relevant double panel structure mounted in a sound transmission loss facility. The primary structure of the double panel system is excited either by a stochastic point force or by a diffuse sound field synthesized in the reverberation room of the transmission loss facility. The secondary structure, which is connected to the frames of the primary structure, is augmented by actuators and sensors implementing an active feedforward control system. Special emphasis is placed on the causality of the active feedforward control system and its implications on the disturbance rejection at the error sensors. The coherence of the sensor signals is analyzed for the two different disturbance excitations. Experimental results are presented regarding the causality, coherence, and disturbance rejection of the active feedforward control system. Furthermore, the sound transmission loss of the double panel system is evaluated for different configurations of the active system. A principal result of this work is the evidence that it is possible to strongly influence the transmission of stochastic disturbance sources through double panel configurations by means of an active feedforward control system.

  2. A pilot study to evaluate the application of a generic protein standard panel for quality control of biomarker detection technologies

    Directory of Open Access Journals (Sweden)

    Valdivia Hernan J

    2011-08-01

    Full Text Available Abstract Background Protein biomarker studies are currently hampered by a lack of measurement standards to demonstrate quality, reliability and comparability across multiple assay platforms. This is especially pertinent for immunoassays where multiple formats for detecting target analytes are commonly used. Findings In this pilot study a generic panel of six non-human protein standards (50 - 10^7 pg/mL of varying abundance was prepared as a quality control (QC material. Simulated "normal" and "diseased" panels of proteins were prepared in pooled human plasma and incorporated into immunoassays using the Meso Scale Discovery® (MSD® platform to illustrate reliable detection of the component proteins. The protein panel was also evaluated as a spike-in material for a model immunoassay involving detection of ovarian cancer biomarkers within individual human plasma samples. Our selected platform could discriminate between two panels of the proteins exhibiting small differences in abundance. Across distinct experiments, all component proteins exhibited reproducible signal outputs in pooled human plasma. When individual donor samples were used, half the proteins produced signals independent of matrix effects. These proteins may serve as a generic indicator of platform reliability. Each of the remaining proteins exhibit differential signals across the distinct samples, indicative of sample matrix effects, with the three proteins following the same trend. This subset of proteins may be useful for characterising the degree of matrix effects associated with the sample which may impact on the reliability of quantifying target diagnostic biomarkers. Conclusions We have demonstrated the potential utility of this panel of standards to act as a generic QC tool for evaluating the reproducibility of the platform for protein biomarker detection independent of serum matrix effects.

  3. WTEC panel report on European nuclear instrumentation and controls. Final report

    Energy Technology Data Exchange (ETDEWEB)

    White, J.D.; Lanning, D.D.; Johnson, P.M.H. [eds.] [World Technology Evaluation Center, Baltimore, MD (United States); Shelton, R.D. [World Technology Evaluation Center, Baltimore, MD (United States)

    1991-12-01

    A study of instrumentation and controls (I and C) technology used in nuclear power plants in Europe was conducted by a panel of US specialists. This study plants in Europe was conducted by a panel of US specialists. This study included a review of the literature on the subject, followed by a visit to some of the leading organizations in Europe in the field nuclear I and C. Areas covered are: (1) role of the operator and control room design; (2) transition from analog to digital technology; (3) computerized operator support systems for fault management; (4) control strategies and techniques; (5) Nuclear power plant I and C architecture; (6) instrumentation and (7) computer standards and tools. The finding relate to poor reactions.

  4. A full scope nuclear power plant simulator for multiple reactor types with virtual control panels

    International Nuclear Information System (INIS)

    Yonezawa, Hisanori; Ueda, Hiroki; Kato, Takahisa

    2017-01-01

    This paper summarizes a full scope nuclear power plant simulator for multiple reactor types with virtual control panels which Toshiba developed and delivered. After the Fukushima DAIICHI nuclear power plants accident, it is required that all the people who are engaged in the design, manufacturing, operation, maintenance, management and regulation for the nuclear power plant should learn the wide and deep knowledge about the nuclear power plant design including the severe accident. For this purpose, the training with a full scope simulator is one of the most suitable ways. However the existing full scope simulators which are consist of the control panels replica of the referenced plants are costly and they are hard to remodel to fit to the real plant of the latest condition. That's why Toshiba developed and delivered the new concept simulator system which covers multiple referenced plants even though they have different design like BWR and PWR. The control panels of the simulator are made by combining 69 large Liquid Crystal Display (LCD) panels with touch screen instead of a control panel replica of referenced plant. The screen size of the each panel is 42 inches and 3 displays are arranged in tandem for one unit and 23 units are connected together. Each panel displays switches, indicators, recorders and lamps with the Computer Graphics (CG) and trainees operate them with touch operations. The simulator includes a BWR and a PWR simulator model, which enable trainees to learn the wide and deep knowledge about the nuclear power plant of BWR and PWR reactor types. (author)

  5. Alarm system for ABWR main control panels

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Yuji; Saito, Koji [Toshiba Corp., Yokohoma (Japan)

    1997-09-01

    TOSHIBA has developed integrated digital control and instrumentation system for ABWR, which is the third-generation man machine interface system for main control room that we call A-PODIA (Advanced PODIA). A-Podia has been introduced the first actual ABWR plant in Japan. in A-PODIA, TOSHIBA has realized improvement of alarm system that all operator crews in the control room can recognize plant anomalies easily. The alarm system can recognize essential alarms for plant safety easily and understand annunciators with each integrated annunciators and their prioritized color easily by classifying alarms into plant-level essential annunciators, system-level integrated annunciators and equipment level individual annunciators with hierarchical structure. This paper describes conventional alarm system and the design philosophy, alarm system design and operation of ``Alarm System for ABWR Main Control Panels``. (author). 5 refs, 8 figs, 1 tab.

  6. Alarm system for ABWR main control panels

    International Nuclear Information System (INIS)

    Kobayashi, Yuji; Saito, Koji

    1997-01-01

    TOSHIBA has developed integrated digital control and instrumentation system for ABWR, which is the third-generation man machine interface system for main control room that we call A-PODIA (Advanced PODIA). A-Podia has been introduced the first actual ABWR plant in Japan. in A-PODIA, TOSHIBA has realized improvement of alarm system that all operator crews in the control room can recognize plant anomalies easily. The alarm system can recognize essential alarms for plant safety easily and understand annunciators with each integrated annunciators and their prioritized color easily by classifying alarms into plant-level essential annunciators, system-level integrated annunciators and equipment level individual annunciators with hierarchical structure. This paper describes conventional alarm system and the design philosophy, alarm system design and operation of ''Alarm System for ABWR Main Control Panels''. (author). 5 refs, 8 figs, 1 tab

  7. A double-panel active segmented partition module using decoupled analog feedback controllers: numerical model.

    Science.gov (United States)

    Sagers, Jason D; Leishman, Timothy W; Blotter, Jonathan D

    2009-06-01

    Low-frequency sound transmission has long plagued the sound isolation performance of lightweight partitions. Over the past 2 decades, researchers have investigated actively controlled structures to prevent sound transmission from a source space into a receiving space. An approach using active segmented partitions (ASPs) seeks to improve low-frequency sound isolation capabilities. An ASP is a partition which has been mechanically and acoustically segmented into a number of small individually controlled modules. This paper provides a theoretical and numerical development of a single ASP module configuration, wherein each panel of the double-panel structure is independently actuated and controlled by an analog feedback controller. A numerical model is developed to estimate frequency response functions for the purpose of controller design, to understand the effects of acoustic coupling between the panels, to predict the transmission loss of the module in both passive and active states, and to demonstrate that the proposed ASP module will produce bidirectional sound isolation.

  8. Human factors inspection of current control room panel in Jose Cabrera NPP

    International Nuclear Information System (INIS)

    Almeida, P.; O'Hara, J.; Higgins, J.

    2002-01-01

    Within the process of renewal of Exploitation Permit of Jose Cabrera Nuclear Power Plant, UNION FENOSA GENERACIO, S. A. (UFG) has carried out an analysis and evaluation project regarding human factors implications of current control room panel arrangement. The project has been developed in two phases. In the first phase, leaded by EPRI and carried out by experts from SAIC, an independent review from a double viewpoint of human reliability and human factors was developed. In the second phase, a multidisciplinary team (composed by human factors, risk analysis, operation, engineering, training and instrumentation and controls experts) has developed a study on human factors implications of current panel arrangement, following the methodology pointed out in NUREG-0711. The project has been developed under the direction of Brookhaven National Laboratory (BNL), organisation that has authored the aforementioned methodology, with the participation of UFG and SOLUZIONA Ingenieria. For the development of the second study the following steps were taken: Firstly, the potential effects of panel arrangement on crew performance were identified its real evidence was analysed and the goals for the improvement of control room operation were established; following NUREG-0711. After this, several design alternatives that addressed these goals were identified and were analysed along three dimensions: human factors, risk analysis and economic costs. Finally the results of these evaluations were combined using a multi-attribute decision method to arrive at a recommended alternative as he best proposal to incorporate human factors criteria and good practices in the design of control room panels. (Author)

  9. WTEC panel report on European nuclear instrumentation and controls. Final report

    International Nuclear Information System (INIS)

    White, J.D.; Lanning, D.D.; Beltracchi, L.; Best, F.R.; Easter, J.R.

    1991-12-01

    A study of instrumentation and controls (I and C) technology used in nuclear power plants in Europe was conducted by a panel of American specialists. The study included a review of the literature on the subject, followed by a visit to some of the leading organizations in Europe in the field of nuclear I and C. The findings of the study are presented in the report. The scope is limited to pressurized water reactors in Czechoslovakia, France, Germany, Norway and Russia. Specific topics include: The role of the operator and control room design; the transition from analog to digital technology; computerized operator support systems for fault management; control strategies and techniques; an investigation of nuclear power plant I and C architecture; instrumentation; computer standards and tools. A companion study is JTEC Panel Report on Nuclear Power in Japan (PB90-215724)

  10. Three-component homeostasis control

    Science.gov (United States)

    Xu, Jin; Hong, Hyunsuk; Jo, Junghyo

    2014-03-01

    Two reciprocal components seem to be sufficient to maintain a control variable constant. However, pancreatic islets adapt three components to control glucose homeostasis. They are α (secreting glucagon), β (insulin), and δ (somatostatin) cells. Glucagon and insulin are the reciprocal hormones for increasing and decreasing blood glucose levels, while the role of somatostatin is unknown. However, it has been known how each hormone affects other cell types. Based on the pulsatile hormone secretion and the cellular interactions, this system can be described as coupled oscillators. In particular, we used the Landau-Stuart model to consider both amplitudes and phases of hormone oscillations. We found that the presence of the third component, δ cell, was effective to resist under glucose perturbations, and to quickly return to the normal glucose level once perturbed. Our analysis suggested that three components are necessary for advanced homeostasis control.

  11. Selection of population controls for a Salmonella case-control study in the UK using a market research panel and web-survey provides time and resource savings.

    Science.gov (United States)

    Mook, P; Kanagarajah, S; Maguire, H; Adak, G K; Dabrera, G; Waldram, A; Freeman, R; Charlett, A; Oliver, I

    2016-04-01

    Timely recruitment of population controls in infectious disease outbreak investigations is challenging. We evaluated the timeliness and cost of using a market research panel as a sampling frame for recruiting controls in a case-control study during an outbreak of Salmonella Mikawasima in the UK in 2013. We deployed a web-survey by email to targeted members of a market research panel (panel controls) in parallel to the outbreak control team interviewing randomly selected public health staff by telephone and completing paper-based questionnaires (staff controls). Recruitment and completion of exposure history web-surveys for panel controls (n = 123) took 14 h compared to 15 days for staff controls (n = 82). The average staff-time cost per questionnaire for staff controls was £13·13 compared to an invoiced cost of £3·60 per panel control. Differences in the distribution of some exposures existed between these control groups but case-control studies using each group found that illness was associated with consumption of chicken outside of the home and chicken from local butchers. Recruiting market research panel controls offers time and resource savings. More rapid investigations would enable more prompt implementation of control measures. We recommend that this method of recruiting controls is considered in future investigations and assessed further to better understand strengths and limitations.

  12. Perancangan Solar Charge Controller dan Inverter pada Aplikasi Solar Panel Berbasis Atmega8535 secara Software

    OpenAIRE

    Larasati, Devi

    2015-01-01

    The purpose of this final project is to apply the codevision AVR ATMega 8535 to process the data on the storage accumulator battery charging current from the solar panels. Value current is processed in the microcontroller is in the current detection using current sensor ACS-712. To prevent backflow from batteries to solar panels when the solar panel voltage is less than accumulator battery voltage, current flows from the solar panels through solar charge controller to the battery before. C...

  13. Sensitivity to plant modelling uncertainties in optimal feedback control of sound radiation from a panel

    DEFF Research Database (Denmark)

    Mørkholt, Jakob

    1997-01-01

    Optimal feedback control of broadband sound radiation from a rectangular baffled panel has been investigated through computer simulations. Special emphasis has been put on the sensitivity of the optimal feedback control to uncertainties in the modelling of the system under control.A model...... in terms of a set of radiation filters modelling the radiation dynamics.Linear quadratic feedback control applied to the panel in order to minimise the radiated sound power has then been simulated. The sensitivity of the model based controller to modelling uncertainties when using feedback from actual...

  14. Aid to Families with Dependent Children Quality Control Review Panel Decisions

    Data.gov (United States)

    U.S. Department of Health & Human Services — Decisions issued by the Aid to Families with Dependent Children (AFDC) Quality Control Review Panel of the Departmental Appeals Board concerning the AFDC program...

  15. Panel Management to Improve Smoking and Hypertension Outcomes by VA Primary Care Teams: A Cluster-Randomized Controlled Trial.

    Science.gov (United States)

    Schwartz, Mark D; Jensen, Ashley; Wang, Binhuan; Bennett, Katelyn; Dembitzer, Anne; Strauss, Shiela; Schoenthaler, Antoinette; Gillespie, Colleen; Sherman, Scott

    2015-07-01

    Panel Management can expand prevention and chronic illness management beyond the office visit, but there is limited evidence for its effectiveness or guidance on how best to incorporate it into practice. We aimed to test the effectiveness of incorporating panel management into clinical practice by incorporating Panel Management Assistants (PMAs) into primary care teams with and without panel management education. We conducted an 8-month cluster-randomized controlled trial of panel management for improving hypertension and smoking cessation outcomes among veterans. Twenty primary care teams from the Veterans Affairs New York Harbor were randomized to control, panel management support, or panel management support plus education groups. Teams included 69 clinical staff serving 8,153 hypertensive and/or smoking veterans. Teams assigned to the intervention groups worked with non-clinical Panel Management Assistants (PMAs) who monitored care gaps and conducted proactive patient outreach, including referrals, mail reminders and motivational interviewing by telephone. Measurements included mean systolic and diastolic blood pressure, proportion of patients with controlled blood pressure, self-reported quit attempts, nicotine replacement therapy (NRT) prescriptions, and referrals to disease management services. Change in mean blood pressure, blood pressure control, and smoking quit rates were similar across study groups. Patients on intervention teams were more likely to receive NRT (OR = 1.4; 95% CI 1.2-1.6) and enroll in the disease management services MOVE! (OR = 1.2; 95% CI 1.1-1.6) and Telehealth (OR = 1.7, 95% CI 1.4-2.1) than patients on control teams. Panel Management support for primary care teams improved process, but not outcome variables among veterans with hypertension and smoking. Incorporating PMAs into teams was feasible and highly valued by the clinical staff, but clinical impact may require a longer intervention.

  16. Environmental variation partitioned into separate heritable components

    DEFF Research Database (Denmark)

    Ørsted, Michael; Rohde, Palle Duun; Hoffmann, Ary A

    2018-01-01

    Trait variation is normally separated into genetic and environmental components, yet genetic factors also control the expression of environmental variation, encompassing plasticity across environmental gradients and within-environment responses. We defined four components of environmental variation......: plasticity across environments, variability in plasticity, variation within environments, and differences in within-environment variation across environments. We assessed these components for cold tolerance across five rearing temperatures using the Drosophila melanogaster Genetic Reference Panel (DGRP...

  17. Panels Manufactured from Vegetable Fibers: An Alternative Approach for Controlling Noises in Indoor Environments

    Directory of Open Access Journals (Sweden)

    Leopoldo Pacheco Bastos

    2012-01-01

    Full Text Available Noise control devices such as panels and barriers, when of high efficiency, generally are of difficult acquisition due to high costs turning in many cases their use impracticable, mainly for limited budget small-sized companies. There is a huge requirement for new acoustic materials that have satisfactory performance, not only under acoustic aspect but also other relevant ones and are of low cost. Vegetable fibers are an alternative solution when used as panels since they promise satisfactory acoustic absorption, according to previous researches, exist in abundance, and derive from renewable sources. This paper, therefore, reports on the development of panels made from vegetable fibers (coconut, palm, sisal, and açaí, assesses their applicability by various experimental (flammability, odor, fungal growth, and ageing tests, and characterize them acoustically in terms of their sound absorption coefficients on a scale model reverberant chamber. Acoustic results point out that the aforementioned fiber panels play pretty well the role of a noise control device since they have compatible, and in some cases, higher performance when compared to commercially available conventional materials.

  18. Component protection based automatic control

    International Nuclear Information System (INIS)

    Otaduy, P.J.

    1992-01-01

    Control and safety systems as well as operation procedures are designed on the basis of critical process parameters limits. The expectation is that short and long term mechanical damage and process failures will be avoided by operating the plant within the specified constraints envelopes. In this paper, one of the Advanced Liquid Metal Reactor (ALMR) design duty cycles events is discussed to corroborate that the time has come to explicitly make component protection part of the control system. Component stress assessment and aging data should be an integral part of the control system. Then transient trajectory planning and operating limits could be aimed at minimizing component specific and overall plant component damage cost functions. The impact of transients on critical components could then be managed according to plant lifetime design goals. The need for developing methodologies for online transient trajectory planning and assessment of operating limits in order to facilitate the explicit incorporation of damage assessment capabilities to the plant control and protection systems is discussed. 12 refs

  19. Automated Intelligent Monitoring and the Controlling Software System for Solar Panels

    OpenAIRE

    Nalamvar, Hitesh Sanzhay; Ivanov, Maksim Anatoljevich; Baydali, Sergey Anatolievich

    2017-01-01

    The inspection of the solar panels on a periodic basis is important to improve longevity and ensure performance of the solar system. To get the most solar potential of the photovoltaic (PV) system is possible through an intelligent monitoring & controlling system. The monitoring & controlling system has rapidly increased its popularity because of its user-friendly graphical interface for data acquisition, monitoring, controlling and measurements. In order to monitor the performance of the sys...

  20. Cleaning Robot for Solar Panels in Solar Power Station

    Science.gov (United States)

    Hang, Lu-Bin; Shen, Cheng-Wei; Bian, Huai-Qiang; Wang, Yan

    2016-05-01

    The dust particles on solar panel surface have been a serious problem for the photovoltaic industry, a new monorail-tracked robot used for automatic cleaning of solar panel is presented in this paper. To meet the requirement of comprehensive and stable cleaning of PV array, the monorail-tracked pattern of robot is introduced based on the monorail structure technique. The running and striding mechanism are designed for mobility of robot on the solar panels. According to the carrying capacity and water circulation mechanism, a type of self-cleaning device with filtering system is developed. Combined with the computer software and communications technology, the control system is built in this robot, which can realize the functions of autonomous operation, positioning and monitoring. The application of this developed cleaning robot can actualize the Industrialization of automatic cleaning for PV components and have wide market prospect.

  1. 75 FR 76987 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP...

    Science.gov (United States)

    2010-12-10

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Epidemiologic and Ecologic...), the Centers for Disease Control and Prevention (CDC) announces the aforementioned meeting: Time and...

  2. 76 FR 4911 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: Occupational...

    Science.gov (United States)

    2011-01-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: Occupational Safety and Health...)(2) of the Federal Advisory Committee Act (Pub. L. 92-463), the Centers for Disease Control and...

  3. 75 FR 4406 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: Occupational...

    Science.gov (United States)

    2010-01-27

    ... recommendations to the Disease, Disability, and Injury Prevention and Control SEP: Occupational Safety and Health... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel: Occupational Safety and Health Training...

  4. Installation package for concentrating solar collector panels

    Science.gov (United States)

    1978-01-01

    The concentrating solar collector panels comprise a complete package array consisting of collector panels using modified Fresnel prismatic lenses for a 10 to 1 concentrating ratio, supporting framework, fluid manifolding and tracking drive system, and unassembled components for field erection.

  5. Active control of radiated sound power from a baffled, rectangular panel

    DEFF Research Database (Denmark)

    Mørkholt, Jakob

    1996-01-01

    with an array of eleven microphones in front of the panel, is very close to minimising the actual radiated sound power. Practical experiments where such an array estimate has been minimised using the filtered X LMS algorithm have shown that substantial reductions of radiated sound power can be obtained over......Active control of radiated sound power from a rectangular baffled panel by minimisation of an accurate power estimate, using piezoceramic actuators, has been investigated. Computer simulations have shown that minimising a power estimate obtained by discretised integration of the far field intensity...... a broad frequency range using few piezoceramic actuators, provided that an accurate estimate of the sound power is available for minimisation....

  6. Comparison of various decentralised structural and cavity feedback control strategies for transmitted noise reduction through a double panel structure

    NARCIS (Netherlands)

    Ho, J.; Berkhoff, Arthur P.

    This paper compares various decentralised control strategies, including structural and acoustic actuator–sensor configuration designs, to reduce noise transmission through a double panel structure. The comparison is based on identical control stability indexes. The double panel structure consists of

  7. Comparison of various decentralised structural and cavity feedback control strategies for transmitted noise reduction through a double panel structure

    NARCIS (Netherlands)

    Ho, J.H.; Berkhoff, A.P.

    2014-01-01

    This paper compares various decentralised control strategies, including structural and acoustic actuator-sensor configuration designs, to reduce noise transmission through a double panel structure. The comparison is based on identical control stability indexes. The double panel structure consists of

  8. Vacuum Insulation Panels - Study on VIP-components and panels for service life prediction of VIP in building applications (Subtask A)

    Energy Technology Data Exchange (ETDEWEB)

    Simmler, H.; Brunner, S. [Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf (Switzerland); Heinemann, U.; Schwab, H. [Bavarian Centre for Applied Energy Research (ZAE Bayern), Garching (Germany); Kumaran, K.; Mukhopadhyaya, P. [National Research Council, Institute for Research in Construction (NRC-IRC), Ottawa (Canada); Quenard, D.; Sallee, H. [Scientific and Technical Centre for Construction (CSTB), Marne la Vallee (France); Noller, K.; Kuecuekpinar-Niarchos, E.; Stramm, C. [Fraunhofer Institute for Process Engineering and Packaging (IVV), Freising (Germany); Tenpierik, M.; Cauberg, H. [Technical University of Delft, Delft (Netherlands); Erb, M. [Dr. Eicher und Pauli AG (Switzerland)

    2005-09-15

    This comprehensive paper takes a look at the properties of vacuum insulation panels (VIP) and was presented as a contribution to the IEA's ECBCS (Energy Conservation in Buildings and Community Systems) Annex 39. The various institutions in Switzerland, Germany, Canada, France, Sweden and the Netherlands participating in the task and their activities are listed. The paper describes the concept of vacuum insulation for buildings and examines the physics involved and core materials that can be used. The physical, mechanical and thermal properties of the core materials are examined and the requirements placed on the envelope of the panels are looked at. Tests made on materials as well as on the complete vacuum insulation panels are described in detail. The results obtained are presented and reviewed. Service-life and quality assurance aspects are also discussed. A comprehensive appendix completes the report.

  9. Panel acoustic contribution analysis.

    Science.gov (United States)

    Wu, Sean F; Natarajan, Logesh Kumar

    2013-02-01

    Formulations are derived to analyze the relative panel acoustic contributions of a vibrating structure. The essence of this analysis is to correlate the acoustic power flow from each panel to the radiated acoustic pressure at any field point. The acoustic power is obtained by integrating the normal component of the surface acoustic intensity, which is the product of the surface acoustic pressure and normal surface velocity reconstructed by using the Helmholtz equation least squares based nearfield acoustical holography, over each panel. The significance of this methodology is that it enables one to analyze and rank relative acoustic contributions of individual panels of a complex vibrating structure to acoustic radiation anywhere in the field based on a single set of the acoustic pressures measured in the near field. Moreover, this approach is valid for both interior and exterior regions. Examples of using this method to analyze and rank the relative acoustic contributions of a scaled vehicle cabin are demonstrated.

  10. Control panel and indicators for production control in building projects

    Directory of Open Access Journals (Sweden)

    Orihuela Pablo

    2018-02-01

    Full Text Available In general, every project should have indicators that monitor compliance with established goals. In con­struction projects, there are a large number of indicators proposed by many researchers; however, an analysis of the state of the art shows a frequent confusion between Result, Process and Leading Indicators. This paper, which is an extended version of the paper sub­mitted by the same authors at the Creative Construction Conference 2017 and published in Procedia Engineering (DOI: 10.1016/j.proeng.2017.07.230, presents a proposal of these three types of indicators for the design, supply and assembly phases of housing projects. Thus, all project stakeholders can have a control panel that will monitor if an indicator exceeds the limits, thereby allowing taking corrective actions in a timely and effective manner.

  11. 78 FR 13677 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Funding...

    Science.gov (United States)

    2013-02-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Funding Opportunity Announcement, Initial Review The meeting announced below concerns Indoor Environment of Low- Income Renovated...

  12. 78 FR 17412 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Funding...

    Science.gov (United States)

    2013-03-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Funding Opportunity Announcement, Initial Review The meeting announced below concerns Indoor Environment of Low- Income Renovated...

  13. Fuselage panel noise attenuation by piezoelectric switching control

    International Nuclear Information System (INIS)

    Makihara, Kanjuro; Onoda, Junjiro; Minesugi, Kenji; Miyakawa, Takeya

    2010-01-01

    This paper describes a problem that we encountered in our noise attenuation project and our solution for it. We intend to attenuate low-frequency noise that transmits through aircraft fuselage panels. Our method of noise attenuation is implemented with a piezoelectric semi-active system having a selective switch instead of an active energy-supply system. The semi-active controller is based on the predicted sound pressure distribution obtained from acoustic emission analysis. Experiments and numerical simulations demonstrate that the semi-active method attenuates acoustic levels of not only the simple monochromatic noise but also of broadband noise. We reveal that tuning the electrical parameters in the circuit is the key to effective noise attenuation, to overcome the acoustic excitation problem due to sharp switching actions, as well as to control chattering problems. The results obtained from this investigation provide meaningful insights into designing noise attenuation systems for comfortable aircraft cabin environments

  14. 75 FR 41872 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Surveillance...

    Science.gov (United States)

    2010-07-19

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Surveillance, Natural History... evaluation of ``Surveillance, Natural History, Quality of Care and Outcomes of Diabetes Mellitus with Onset...

  15. 75 FR 13560 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Surveillance...

    Science.gov (United States)

    2010-03-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Surveillance, Natural History... evaluation of ``Surveillance, Natural History, Quality of Care and Outcomes of Diabetes Mellitus With Onset...

  16. 76 FR 13413 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP); Meeting

    Science.gov (United States)

    2011-03-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP); Meeting Studies at the Animal-Human Interface of Influenza and Other Zoonotic Diseases in Vietnam, Funding Opportunity Announcement...

  17. 76 FR 27327 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Meeting

    Science.gov (United States)

    2011-05-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Meeting Studies at the Animal-Human Interface of Influenza and Other Zoonotic Diseases in Vietnam, Funding Opportunity Announcement...

  18. Artificial Neural Network based control for PV/T panel to track optimum thermal and electrical power

    International Nuclear Information System (INIS)

    Ben Ammar, Majed; Chaabene, Maher; Chtourou, Zied

    2013-01-01

    Highlights: ► We establish a state model of PV/T panel. ► We study the effect of mass flow rate on PV/T efficiency. ► A real time PV/T control algorithm is proposed. ► A model based optimal thermal and electrical power operation point is tracked. - Abstract: As solar energy is intermittent, many algorithms and electronics have been developed to track the maximum power generation from photovoltaic and thermal panels. Following technological advances, these panels are gathered into one unit: PV/T system. PV/T delivers simultaneously two kinds of power: electrical power and thermal power. Nevertheless, no control systems have been developed in order to track maximum power generation from PV/T system. This paper suggests a PV/T control algorithm based on Artificial Neural Network (ANN) to detect the optimal power operating point (OPOP) by considering PV/T model behavior. The OPOP computes the optimum mass flow rate of PV/T for a considered irradiation and ambient temperature. Simulation results demonstrate great concordance between OPOP model based calculation and ANN outputs.

  19. 78 FR 78964 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-12-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns The Cooperative Re-Engagement Controlled Trial (CoRECT), Funding Opportunity...

  20. 78 FR 35035 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial review

    Science.gov (United States)

    2013-06-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial review The meeting announced below concerns Centers for Disease Control and Prevention Public Health Preparedness and Response...

  1. 78 FR 36785 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-06-19

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Centers for Disease Control and Prevention Public Health Preparedness and Response...

  2. 78 FR 732 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-01-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Identification, Surveillance, and Control of Vector-Borne and Zoonotic Infectious...

  3. 76 FR 3909 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Family...

    Science.gov (United States)

    2011-01-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Family History and Diamond..., discussion, and evaluation of ``Family History and Diamond Blackfan Anemia, DD11-010, initial review...

  4. 76 FR 10908 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Maternal...

    Science.gov (United States)

    2011-02-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Maternal Vitamin D Status and... 17, 2011. Elaine L. Baker, Director, Management Analysis and Services Office, Centers for Disease...

  5. Paneling architectural freeform surfaces

    KAUST Repository

    Eigensatz, Michael

    2010-07-25

    The emergence of large-scale freeform shapes in architecture poses big challenges to the fabrication of such structures. A key problem is the approximation of the design surface by a union of patches, so-called panels, that can be manufactured with a selected technology at reasonable cost, while meeting the design intent and achieving the desired aesthetic quality of panel layout and surface smoothness. The production of curved panels is mostly based on molds. Since the cost of mold fabrication often dominates the panel cost, there is strong incentive to use the same mold for multiple panels. We cast the major practical requirements for architectural surface paneling, including mold reuse, into a global optimization framework that interleaves discrete and continuous optimization steps to minimize production cost while meeting user-specified quality constraints. The search space for optimization is mainly generated through controlled deviation from the design surface and tolerances on positional and normal continuity between neighboring panels. A novel 6-dimensional metric space allows us to quickly compute approximate inter-panel distances, which dramatically improves the performance of the optimization and enables the handling of complex arrangements with thousands of panels. The practical relevance of our system is demonstrated by paneling solutions for real, cutting-edge architectural freeform design projects.

  6. Paneling architectural freeform surfaces

    KAUST Repository

    Eigensatz, Michael

    2010-07-26

    The emergence of large-scale freeform shapes in architecture poses big challenges to the fabrication of such structures. A key problem is the approximation of the design surface by a union of patches, socalled panels, that can be manufactured with a selected technology at reasonable cost, while meeting the design intent and achieving the desired aesthetic quality of panel layout and surface smoothness. The production of curved panels is mostly based on molds. Since the cost of mold fabrication often dominates the panel cost, there is strong incentive to use the same mold for multiple panels. We cast the major practical requirements for architectural surface paneling, including mold reuse, into a global optimization framework that interleaves discrete and continuous optimization steps to minimize production cost while meeting user-specified quality constraints. The search space for optimization is mainly generated through controlled deviation from the design surface and tolerances on positional and normal continuity between neighboring panels. A novel 6-dimensional metric space allows us to quickly compute approximate inter-panel distances, which dramatically improves the performance of the optimization and enables the handling of complex arrangements with thousands of panels. The practical relevance of our system is demonstrated by paneling solutions for real, cutting-edge architectural freeform design projects. © 2010 ACM.

  7. Active control of sound transmission through a rectangular panel using point-force actuators and piezoelectric film sensors.

    Science.gov (United States)

    Sanada, Akira; Higashiyama, Kouji; Tanaka, Nobuo

    2015-01-01

    This study deals with the active control of sound transmission through a rectangular panel, based on single input, single output feedforward vibration control using point-force actuators and piezoelectric film sensors. It focuses on the phenomenon in which the sound power transmitted through a finite-sized panel drops significantly at some frequencies just below the resonance frequencies of the panel in the low-frequency range as a result of modal coupling cancellation. In a previous study, it was shown that when point-force actuators are located on nodal lines for the frequency at which this phenomenon occurs, a force equivalent to the incident sound wave can act on the panel. In this study, a practical method for sensing volume velocity using a small number of piezoelectric film strips is investigated. It is found that two quadratically shaped piezoelectric film strips, attached at the same nodal lines as those where the actuators were placed, can sense the volume velocity approximately in the low-frequency range. Results of simulations show that combining the proposed actuation method and the sensing method can achieve a practical control effect at low frequencies over a wide frequency range. Finally, experiments are carried out to demonstrate the validity and feasibility of the proposed method.

  8. 78 FR 17411 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-03-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Monitoring and Evaluation of Malaria Control and Elimination Activities, FOA GH13...

  9. The Improvement of Thermal Insulating Concrete Panel

    Directory of Open Access Journals (Sweden)

    Mohammed Ali Nasser Ali

    2018-05-01

    Full Text Available The Iraqi houses flattening the roof by a concrete panel, and because of the panels on the top directly exposed to the solar radiation become unbearably hot and cold during the summer and winter. The traditional concrete panel components are cement, sand, and aggregate, which have a poor thermal property. The usage of materials with low thermal conductivity with no negative reflects on its mechanical properties gives good improvements to the thermal properties of the concrete panel. The practical part of this work was built on a multi-stage mixing plan. In the first stage the mixing ratio based on the ratios of the sand to cement. The second stage mixing ratios based on replacing the coarse aggregate quantities with the Alabaster aggregates, and the third stage the mixing ratios based on the replacement of wood ash instead of the sand. While the fourth stage mixing ratios based on decreasing the thermal conductivity and increasing mechanical properties by adding a multilayer of a plastic net. The result shows that using a concrete panel with components (cement, sand, coarse aggregate, wood ash, and Alabaster aggregates with a mass ratio of (1:1:2:1:1 and 3-plastic layers, gives the best improvement of the thermal properties. Where, the thermal conductivity is reduced by 42% and the specific heat increased by 41.2% as compared to the traditional concrete panel mixing ratio, with mechanical properties are agreed with the Iraqi standards.

  10. 76 FR 13621 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Family...

    Science.gov (United States)

    2011-03-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Family History and Diamond Blackfan Anemia, DD11- 010, Initial Review Correction: This notice was published in the Federal Register on...

  11. 75 FR 29561 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Surveillance...

    Science.gov (United States)

    2010-05-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Surveillance, Natural History, Quality of Care and Outcomes of Diabetes Mellitus with Onset in Childhood and Adolescence, RFA DP 10-001...

  12. 76 FR 9018 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Emerging...

    Science.gov (United States)

    2011-02-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Emerging Infections Sentinel... with Section 10(a)(2) of the Federal Advisory Committee Act (Pub. L. 92-463), the Centers for Disease...

  13. 78 FR 23768 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-04-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting... Centers for Disease Control and Prevention (CDC) announces the aforementioned SEP: Time and Date: 1:00 p.m...

  14. Panel fabrication utilizing GaAs solar cells

    Science.gov (United States)

    Mardesich, N.

    1984-01-01

    The development of the GaAs solar cells for space applications is described. The activities in the fabrication of GaAs solar panels are outlined. Panels were fabricated while introducing improved quality control, soldering laydown and testing procedures. These panels include LIPS II, San Marco Satellite, and a low concentration panel for Rockwells' evaluation. The panels and their present status are discussed.

  15. Thin film photovoltaic panel and method

    Science.gov (United States)

    Ackerman, Bruce; Albright, Scot P.; Jordan, John F.

    1991-06-11

    A thin film photovoltaic panel includes a backcap for protecting the active components of the photovoltaic cells from adverse environmental elements. A spacing between the backcap and a top electrode layer is preferably filled with a desiccant to further reduce water vapor contamination of the environment surrounding the photovoltaic cells. The contamination of the spacing between the backcap and the cells may be further reduced by passing a selected gas through the spacing subsequent to sealing the backcap to the base of the photovoltaic panels, and once purged this spacing may be filled with an inert gas. The techniques of the present invention are preferably applied to thin film photovoltaic panels each formed from a plurality of photovoltaic cells arranged on a vitreous substrate. The stability of photovoltaic conversion efficiency remains relatively high during the life of the photovoltaic panel, and the cost of manufacturing highly efficient panels with such improved stability is significantly reduced.

  16. 75 FR 78999 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Maternal...

    Science.gov (United States)

    2010-12-17

    ..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Maternal Vitamin D Status and... Committee Act (Pub. L. 92-463), the Centers for Disease Control and Prevention (CDC) announces the..., discussion, and evaluation of ``Maternal Vitamin D Status and Preterm Birth, DP11-002, initial review...

  17. 78 FR 24751 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-04-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting... Control and Prevention (CDC) announces the aforementioned SEP: Time and Date: 12:00 p.m.-3:30 p.m., June...

  18. Inclusion of Population-specific Reference Panel from India to the 1000 Genomes Phase 3 Panel Improves Imputation Accuracy.

    Science.gov (United States)

    Ahmad, Meraj; Sinha, Anubhav; Ghosh, Sreya; Kumar, Vikrant; Davila, Sonia; Yajnik, Chittaranjan S; Chandak, Giriraj R

    2017-07-27

    Imputation is a computational method based on the principle of haplotype sharing allowing enrichment of genome-wide association study datasets. It depends on the haplotype structure of the population and density of the genotype data. The 1000 Genomes Project led to the generation of imputation reference panels which have been used globally. However, recent studies have shown that population-specific panels provide better enrichment of genome-wide variants. We compared the imputation accuracy using 1000 Genomes phase 3 reference panel and a panel generated from genome-wide data on 407 individuals from Western India (WIP). The concordance of imputed variants was cross-checked with next-generation re-sequencing data on a subset of genomic regions. Further, using the genome-wide data from 1880 individuals, we demonstrate that WIP works better than the 1000 Genomes phase 3 panel and when merged with it, significantly improves the imputation accuracy throughout the minor allele frequency range. We also show that imputation using only South Asian component of the 1000 Genomes phase 3 panel works as good as the merged panel, making it computationally less intensive job. Thus, our study stresses that imputation accuracy using 1000 Genomes phase 3 panel can be further improved by including population-specific reference panels from South Asia.

  19. The Bilirubin Binding Panel: A Henderson-Hasselbalch Approach to Neonatal Hyperbilirubinemia.

    Science.gov (United States)

    Ahlfors, Charles E

    2016-10-01

    Poor plasma bilirubin binding increases the risk of bilirubin neurotoxicity in newborns with hyperbilirubinemia. New laboratory tests may soon make it possible to obtain a complete bilirubin binding panel when evaluating these babies. The 3 measured components of the panel are the plasma total bilirubin concentration (B Total ), which is currently used to guide clinical care; the bilirubin binding capacity (BBC); and the concentration of non-albumin bound or free bilirubin (B Free ). The fourth component is the bilirubin-albumin equilibrium dissociation constant, K D , which is calculated from B Total , BBC, and B Free The bilirubin binding panel is comparable to the panel of components used in the Henderson-Hasselbalch approach to acid-base assessment. Bilirubin binding population parameters (not prospective studies to determine whether the new bilirubin binding panel components are better predictors of bilirubin neurotoxicity than B Total ) are needed to expedite the clinical use of bilirubin binding. At any B Total , the B Free and the relative risk of bilirubin neurotoxicity increase as the K D /BBC ratio increases (ie, bilirubin binding worsens). Comparing the K D /BBC ratio of newborns with B Total of concern with that typical for the population helps determine whether the risk of bilirubin neurotoxicity varies significantly from the inherent risk at that B Total Furthermore, the bilirubin binding panel individualizes care because it helps to determine how aggressive intervention should be at any B Total , irrespective of whether it is above or below established B Total guidelines. The bilirubin binding panel may reduce anxiety, costs, unnecessary treatment, and the likelihood of undetected bilirubin neurotoxicity. Copyright © 2016 by the American Academy of Pediatrics.

  20. 76 FR 18766 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-04-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Epidemiologic Research and Surveillance in Epilepsy, Funding Opportunity...

  1. 78 FR 19490 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panels (SEP): Initial Review

    Science.gov (United States)

    2013-04-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panels (SEP): Initial Review The meeting announced below concerns Monitoring Cause-Specific School Absenteeism for Estimating Community Wide...

  2. 77 FR 25180 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-04-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Conducting Research on Moderate Acute Malnutrition in Humanitarian Emergencies...

  3. 77 FR 20822 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-04-06

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Detecting Emerging Vector- Borne Zoonotic Pathogens in Indonesia, Funding...

  4. 78 FR 15015 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panels (SEP): Initial Review

    Science.gov (United States)

    2013-03-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panels (SEP): Initial Review The meeting announced below concerns Epidemiology, Prevention and Treatment of Influenza and other Respiratory...

  5. 77 FR 14806 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-03-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Epidemiology, Prevention and Treatment of Influenza and Other Respiratory...

  6. 78 FR 78966 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-12-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Epidemiology, Prevention, and Treatment of Influenza and Other Respiratory...

  7. 77 FR 4048 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-01-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Evaluation of Dengue Epidemiology, Outcomes, and Prevention in Sentinel...

  8. 77 FR 4047 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-01-26

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Epidemiology, Prevention and Treatment of Influenza and Other Respiratory...

  9. 78 FR 13677 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panels (SEP): Initial Review

    Science.gov (United States)

    2013-02-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panels (SEP): Initial Review The meeting announced below concerns Monitoring Cause-Specific School Absenteeism for Estimating Community Wide...

  10. 78 FR 60878 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-10-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Health Promotion and Disease Prevention Research Centers, Funding Opportunity...

  11. 77 FR 12844 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-03-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Detecting Emerging Vector- Borne Zoonotic Pathogens in Indonesia, Funding...

  12. Nuclear thermal propulsion technology: Results of an interagency panel in FY 1991

    International Nuclear Information System (INIS)

    Clark, J.S.; Mcdaniel, P.; Howe, S.; Helms, I.; Stanley, M.

    1993-04-01

    NASA LeRC was selected to lead nuclear propulsion technology development for NASA. Also participating in the project are NASA MSFC and JPL. The U.S. Department of Energy will develop nuclear technology and will conduct nuclear component, subsystem, and system testing at appropriate DOE test facilities. NASA program management is the responsibility of NASA/RP. The project includes both nuclear electric propulsion (NEP) and nuclear thermal propulsion (NTP) technology development. This report summarizes the efforts of an interagency panel that evaluated NTP technology in 1991. Other panels were also at work in 1991 on other aspects of nuclear propulsion, and the six panels worked closely together. The charters for the other panels and some of their results are also discussed. Important collaborative efforts with other panels are highlighted. The interagency (NASA/DOE/DOD) NTP Technology Panel worked in 1991 to evaluate nuclear thermal propulsion concepts on a consistent basis. Additionally, the panel worked to continue technology development project planning for a joint project in nuclear propulsion for the Space Exploration Initiative (SEI). Five meetings of the panel were held in 1991 to continue the planning for technology development of nuclear thermal propulsion systems. The state-of-the-art of the NTP technologies was reviewed in some detail. The major technologies identified were as follows: fuels, coatings, and other reactor technologies; materials; instrumentation, controls, health monitoring and management, and associated technologies; nozzles; and feed system technology, including turbopump assemblies

  13. 76 FR 32213 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP); Initial Review

    Science.gov (United States)

    2011-06-03

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP); Initial Review The meeting announced below concerns Human Immunodeficiency Virus (HIV) Prevention Projects for Young Men of Color...

  14. 76 FR 52330 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-08-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Member Conflict Review, Program Announcement (PA) 07-318, initial review. In...

  15. 76 FR 78263 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-12-16

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Occupational Safety and Health Training Project Grants, Program Announcement PAR 10...

  16. 77 FR 19018 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-03-29

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Conducting Public Health Research in South Africa, Funding Opportunity Announcement...

  17. 77 FR 39497 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-07-03

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Special Interest Projects (SIPs): Nutrition and Obesity Policy Research and...

  18. 77 FR 39498 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-07-03

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Special Interest Project (SIP): Assessing the Pregnancy Prevention Needs of HIV...

  19. 76 FR 18555 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-04-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Virologic Evaluation of the Modes of Influenza Virus Transmission among Humans...

  20. 78 FR 25743 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-05-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Member Conflict Review, Program Announcement (PA) 07-318, initial review. In...

  1. 77 FR 7164 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-02-10

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Member Conflict Review, Program Announcement (PA) 07-318, initial review. In...

  2. 78 FR 17412 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-03-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Strengthening the Monitoring and Evaluation of Programs for the Elimination and...

  3. 78 FR 1212 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-01-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Natural History and Prevention of Viral Hepatitis Among Alaska Natives, Funding...

  4. 76 FR 28790 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-05-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Member Conflict Review, Program Announcement (PA) 07-318, initial review. In...

  5. 78 FR 62636 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-10-22

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Cooperative Agreement on Occupational Health with the World Health Organization...

  6. 76 FR 29756 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-05-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Centers for Agricultural Disease and Injury Research, Education, and Prevention...

  7. 76 FR 67458 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-11-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Emerging Infections Programs, Funding Opportunity Announcement (FOA) CK12-1202...

  8. 77 FR 48986 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-08-15

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Member Conflict Review, Program Announcement (PA) 07-318, initial review. In...

  9. 78 FR 17410 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panels (SEP): Initial review

    Science.gov (United States)

    2013-03-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panels (SEP): Initial review The meeting announced below concerns Epi-Centers for the Prevention of Healthcare-Associated Infections, Antimicrobial...

  10. 78 FR 37542 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-06-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns NIOSH Cooperative Agreement Research to Aid Recovery from Hurricane Sandy, Request...

  11. 76 FR 33305 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-06-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Program to Support New Implementation of State or Territorial Public Health...

  12. 77 FR 28392 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-05-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Alcohol-related Motor Vehicle Injury Research, FOA CE12-006, initial review. In...

  13. 78 FR 60879 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-10-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns National Center for Construction Safety and Health Research and Translation (U60...

  14. 77 FR 291 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-01-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns National HIV Behavioral Surveillance For Young Men Who Have Sex With Men, Funding...

  15. 78 FR 60877 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-10-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Occupational Safety and Health Training Project Grants (T03), PAR-10-288, initial...

  16. 77 FR 30015 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-05-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Characterizing the Short and Long Term Consequences of Traumatic Brain Injury (TBI...

  17. 77 FR 31018 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-05-24

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Member Conflict Review, Program Announcement (PA) 07-318, and Centers of Excellence...

  18. 76 FR 33304 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-06-08

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Strategies to Improve Vaccination Coverage of Children in Child Care Centers (CCCs...

  19. 77 FR 22326 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-04-13

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Extension of the World Trade Center Health Registry (U50) Request for Applications...

  20. 77 FR 28393 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-05-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Research to Prevent Prescription Drug Overdoses, FOA CE12-007, initial review. In...

  1. 77 FR 25181 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-04-27

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Research Technical Assistance To The Ministry Of Public Health Of Haiti To Support...

  2. 78 FR 60875 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-10-02

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Occupational Safety and Health Training Project Grants (T03), PAR-10-288, initial...

  3. 76 FR 24031 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-04-29

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Strategies to Improve Vaccination Coverage of Children in Child Care Centers (CCCs...

  4. 76 FR 39879 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-07-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Human Immunodeficiency Virus (HIV) Prevention Projects for Young Men of Color Who...

  5. 77 FR 27460 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-05-10

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Conducting Public Health Research in China RFA GH-12-005, and Conducting Public...

  6. 76 FR 59133 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-09-23

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Human Immunodeficiency Virus (HIV) Prevention Projects for Young Men of Color Who...

  7. 78 FR 9926 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-02-12

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Medicaid Expansion and Reproductive Health Care for Women, FOA DP 13-002, initial...

  8. 77 FR 61756 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-10-11

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Occupational Safety and Health Training Project Grant, PAR 10-288, initial review...

  9. 76 FR 45575 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2011-07-29

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Human Immunodeficiency Virus (HIV) Prevention Projects for Young Men of Color Who...

  10. 78 FR 56236 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-09-12

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns NIOSH Member Conflict Review, PA 07-318, initial review. In accordance with Section...

  11. 77 FR 36544 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-06-19

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting announced below concerns Coordinating Center for Research and Training to Promote the Health of People with...

  12. 77 FR 5026 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2012-02-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting... SEP: Occupational Safety and Health Education and Research Centers, PAR 10-217. Contact Person For...

  13. Smart wave filtering method of a rectangular panel using Hilbert transformers and its application to an adaptive control system

    International Nuclear Information System (INIS)

    Iwamoto, Hiroyuki; Tanaka, Nobuo; Hill, Simon G

    2010-01-01

    This paper concerns the active vibration control of a rectangular panel using smart sensors from the viewpoint of an active wave control theory. The objective of this paper is to present a new type of filter which enables the measurement of the wave amplitude of a rectangular panel in real time for the application of an adaptive feedforward control system which inactivates vibration modes. Firstly, a novel wave filtering method using smart PVDF sensors is proposed. It is found that the shaping function of smart sensors is a complex function. To realize the smart sensor in a practical situation, a Hilbert transformer is utilized to implement a phase shifter of 90° for broadband frequencies. Then, from the viewpoint of a numerical analysis, the characteristics of the proposed wave filter and the performance of the adaptive feedforward control system using the wave filter are discussed. Finally, experiments implementing the active wave control theory which uses the proposed wave filter are conducted, demonstrating the validity of the proposed method in suppressing the vibration of a rectangular panel

  14. Performance comparison between silicon solar panel and dye-sensitized solar panel in Malaysia

    Science.gov (United States)

    Hamed, N. K. A.; Ahmad, M. K.; Urus, N. S. T.; Mohamad, F.; Nafarizal, N.; Ahmad, N.; Soon, C. F.; Ameruddin, A. S.; Faridah, A. B.; Shimomura, M.; Murakami, K.

    2017-09-01

    In carrying out experimental research in performance between silicon solar panel and dye-sensitive solar panel, we have been developing a device and a system. This system has been developed consisting of controllers, hardware and software. This system is capable to get most of the input sources. If only need to change the main circuit and coding for a different source input value. This device is able to get the ambient temperature, surface temperature, surrounding humidity, voltage with load, current with load, voltage without load and current without load and save the data into external memory. This device is able to withstand the heat and rain as it was fabricated in a waterproof box. This experiment was conducted to examine the performance of both the solar panels which are capable to maintain their stability and performance. A conclusion based on data populated, the distribution of data for dye-sensitized solar panel is much better than silicon solar panel as dye-sensitized solar panel is very sensitive to heat and not depend only on midday where is that is the maximum ambient temperature for both solar panel as silicon solar panel only can give maximum and high output only when midday.

  15. Advanced solar panel designs

    Science.gov (United States)

    Ralph, E. L.; Linder, E.

    1995-01-01

    This paper describes solar cell panel designs that utilize new hgih efficiency solar cells along with lightweight rigid panel technology. The resulting designs push the W/kg and W/sq m parameters to new high levels. These new designs are well suited to meet the demand for higher performance small satellites. This paper reports on progress made on two SBIR Phase 1 contracts. One panel design involved the use of large area (5.5 cm x 6.5 cm) GaAs/Ge solar cells of 19% efficiency combined with a lightweight rigid graphite fiber epoxy isogrid substrate configuration. A coupon (38 cm x 38 cm) was fabricated and tested which demonstrated an array specific power level of 60 W/kg with a potential of reaching 80 W/kg. The second panel design involved the use of newly developed high efficiency (22%) dual junction GaInP2/GaAs/Ge solar cells combined with an advanced lightweight rigid substrate using aluminum honeycomb core with high strength graphite fiber mesh facesheets. A coupon (38 cm x 38 cm) was fabricated and tested which demonstrated an array specific power of 105 W/kg and 230 W/sq m. This paper will address the construction details of the panels and an a analysis of the component weights. A strawman array design suitable for a typical small-sat mission is described for each of the two panel design technologies being studied. Benefits in respect to weight reduction, area reduction, and system cost reduction are analyzed and compared to conventional arrays.

  16. 78 FR 19269 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-03-29

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review Notice of Cancellation: This document corrects a notice that was published in the Federal Register on March 21, 2013 (78...

  17. 78 FR 66938 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-11-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review Notice of..., Number 181, Page 57391). This SEP, scheduled to convene on November 12-15, 2013, is canceled. Notice will...

  18. 78 FR 19490 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-04-01

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review Notice of Cancellation: A notice was published in the Federal Register on February 12, 2013, Volume 78, Number 29, page...

  19. 78 FR 66937 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-11-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review Notice of... Volume 78, Number 191, Page 60877). This SEP, scheduled to convene on November 6, 2013, is canceled...

  20. Industrial based volume manufacturing of lightweight aluminium alloy panel components with high-strength and complex-shape for car body and chassis structures

    Science.gov (United States)

    Anyasodor, Gerald; Koroschetz, Christian

    2017-09-01

    To achieve the high volume manufacture of lightweight passenger cars at economic cost as required in the automotive industry, low density materials and new process route will be needed. While high strength aluminium alloy grades: AA7075 and AA6082 may provide the alternative material solution, hot stamping process used for high-strength and ultrahigh strength steels such as boron steel 22mnb5 can enable the volume manufacture of panel components with high-strength and complex-shape for car body and chassis structures. These aluminium alloy grades can be used to manufacture panel components with possible yield strengths ≥ 500 MPa. Due to the differences in material behaviors, hot stamping process of 22mnb5 cannot be directly applied to high strength aluminium alloy grades. Despite recorded successes in laboratories, researches and niche hot forming processes of high strength aluminium alloy grades, not much have been achieved for adequate and efficient volume manufacturing system applicable in the automotive industry. Due to lack of such system and based on expert knowledge in hot stamping production-line, AP&T presents in this paper a hot stamping processing route for high strength aluminium alloys been suitable for production-line development and volume manufacturing.

  1. Self-reverse-biased solar panel optical receiver for simultaneous visible light communication and energy harvesting.

    Science.gov (United States)

    Shin, Won-Ho; Yang, Se-Hoon; Kwon, Do-Hoon; Han, Sang-Kook

    2016-10-31

    We propose a self-reverse-biased solar panel optical receiver for energy harvesting and visible light communication. Since the solar panel converts an optical component into an electrical component, it provides both energy harvesting and communication. The signal component can be separated from the direct current component, and these components are used for communication and energy harvesting. We employed a self-reverse-biased receiver circuit to improve the communication and energy harvesting performance. The reverse bias on the solar panel improves the responsivity and response time. The proposed system achieved 17.05 mbps discrete multitone transmission with a bit error rate of 1.1 x 10-3 and enhanced solar energy conversion efficiency.

  2. 78 FR 28221 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-05-14

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting... aforementioned SEP: Time and Date: 12:30 p.m.-5:00 p.m. EDT, July 24, 2013 (Closed). Place: Teleconference...

  3. 78 FR 57391 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-09-18

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review The meeting... aforementioned SEP: Times and Dates: 8:00 a.m.-8:00 p.m., November 12-15, 2013 (Closed). Place: Teleconference...

  4. Origami-Inspired Folding of Thick, Rigid Panels

    Science.gov (United States)

    Trease, Brian P.; Thomson, Mark W.; Sigel, Deborah A.; Walkemeyer, Phillip E.; Zirbel, Shannon; Howell, Larry; Lang, Robert

    2014-01-01

    To achieve power of 250 kW or greater, a large compression ratio of stowed-to-deployed area is needed. Origami folding patterns were used to inspire the folding of a solar array to achieve synchronous deployment; however, origami models are generally created for near-zero-thickness material. Panel thickness is one of the main challenges of origami-inspired design. Three origami-inspired folding techniques (flasher, square twist, and map fold) were created with rigid panels and hinges. Hinge components are added to the model to enable folding of thick, rigid materials. Origami models are created assuming zero (or near zero) thickness. When a material with finite thickness is used, the panels are required to bend around an increasingly thick fold as they move away from the center of the model. The two approaches for dealing with material thickness are to use membrane hinges to connect the panels, or to add panel hinges, or hinges of the same thickness, at an appropriate width to enable folding.

  5. Maximizing Output Power of a Solar Panel via Combination of Sun Tracking and Maximum Power Point Tracking by Fuzzy Controllers

    Directory of Open Access Journals (Sweden)

    Mohsen Taherbaneh

    2010-01-01

    Full Text Available In applications with low-energy conversion efficiency, maximizing the output power improves the efficiency. The maximum output power of a solar panel depends on the environmental conditions and load profile. In this paper, a method based on simultaneous use of two fuzzy controllers is developed in order to maximize the generated output power of a solar panel in a photovoltaic system: fuzzy-based sun tracking and maximum power point tracking. The sun tracking is performed by changing the solar panel orientation in horizontal and vertical directions by two DC motors properly designed. A DC-DC converter is employed to track the solar panel maximum power point. In addition, the proposed system has the capability of the extraction of solar panel I-V curves. Experimental results present that the proposed fuzzy techniques result in increasing of power delivery from the solar panel, causing a reduction in size, weight, and cost of solar panels in photovoltaic systems.

  6. 78 FR 20319 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review.

    Science.gov (United States)

    2013-04-04

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review. The meeting... aforementioned SEP: Time and Date: 9:00 a.m.-6:00 p.m., May 15-16, 2013 (Closed). Place: Georgian Terrace, 659...

  7. Control device for automatic orientation of a solar panel based on a microcontroller (PIC16f628a)

    Science.gov (United States)

    Rezoug, M. R.; Krama, A.

    2016-07-01

    This work proposes a control device for autonomous solar tracker based on one axis, It consists of two main parts; the control part which is based on "the PIC16f628a"; it has the role of controlling, measuring and plotting responses. The second part is a mechanical device, which has the role of making the solar panel follows the day-night change of the sun throughout the year. Both parties are established to improve energy generation of the photovoltaic panels. In this paper, we will explain the main operating principles of our system. Also, we will provide experimental results which demonstrate the good performance and the efficiency of this system. This innovation is different from what has been proposed in previous studies. The important points of this system are maximum output energy and minimum energy consumption of solar tracker, its cost is relatively low with simplicity in implementation. The average power increase produced by using the tracking system for a particular day, is over 30 % compared with the static panel.

  8. Hydrology of Quirke and Panel uranium tailings basins

    International Nuclear Information System (INIS)

    King, R.M.; MacPhie, L.

    1991-11-01

    The research project described by this report provides the AECB with an independent assessment of the 'saturated tailings concept' for the decommissioning of tailing areas at the Rio Algom Quirke and Panel uranium mines near Elliot Lake in Northern Ontario. Hydrologic and hydraulic modelling for each facility showed the interrelation between the design of the water-level control facilities and the water levels in each cell for design flood and extreme low-flow conditions, taking into account all water-balance components. The estimate of seepage rates through the tailings mass is identified as a critical issue

  9. DC current distribution mapping system of the solar panels using a HTS-SQUID gradiometer

    International Nuclear Information System (INIS)

    Miyazaki, Shingo; Kasuya, Syohei; Saari, Mohd Mawardi; Sakai, Kenji; Kiwa, Toshihiko; Tsukada, Keiji; Tsukamoto, Akira; Adachi, Seiji; Tanabe, Keiichi

    2014-01-01

    Solar panels are expected to play a major role as a source of sustainable energy. In order to evaluate solar panels, non-destructive tests, such as defect inspections and response property evaluations, are necessary. We developed a DC current distribution mapping system of the solar panels using a High Critical Temperature Superconductor Superconducting Quantum Interference Device (HTS-SQUID) gradiometer with ramp edge type Josephson junctions. Two independent components of the magnetic fields perpendicular to the panel surface (∂Bz/∂x, ∂Bz/∂y) were detected. The direct current of the solar panel is visualized by calculating the composition of the two signal components, the phase angle, and mapping the DC current vector. The developed system can evaluate the uniformity of DC current distributions precisely and may be applicable for defect detection of solar panels.

  10. Optimization of composite panels using neural networks and genetic algorithms

    NARCIS (Netherlands)

    Ruijter, W.; Spallino, R.; Warnet, Laurent; de Boer, Andries

    2003-01-01

    The objective of this paper is to present first results of a running study on optimization of aircraft components (composite panels of a typical vertical tail plane) by using Genetic Algorithms (GA) and Neural Networks (NN). The panels considered are standardized to some extent but still there is a

  11. Finite element predictions of active buckling control of stiffened panels

    Science.gov (United States)

    Thompson, Danniella M.; Griffin, O. H., Jr.

    1993-04-01

    Materials systems and structures that can respond 'intelligently' to their environment are currently being proposed and investigated. A series of finite element analyses was performed to investigate the potential for active buckling control of two different stiffened panels by embedded shape memory alloy (SMA) rods. Changes in the predicted buckling load increased with the magnitude of the actuation level for a given structural concept. Increasing the number of actuators for a given concept yielded greater predicted increases in buckling load. Considerable control authority was generated with a small number of actuators, with greater authority demonstrated for those structural concepts where the activated SMA rods could develop greater forces and moments on the structure. Relatively simple and inexpensive analyses were performed with standard finite elements to determine such information, indicating the viability of these types of models for design purposes.

  12. 76 FR 20355 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Funding...

    Science.gov (United States)

    2011-04-12

    ..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Funding Opportunity Announcement... Research Network (MD STARnet); Feasibility of Expansion to Other Muscular Dystrophies (FOA) DD11-006... Network (MD STARnet); Feasibility of Expansion to Other Muscular Dystrophies (FOA) DD11-006, initial...

  13. Optimizing the human engineering design of control panels in nuclear power plant control rooms

    International Nuclear Information System (INIS)

    Behrendt, V.; Krehbiehl, T.; Hartfiel, H.D.; Mannhaupt, H.R.

    1986-12-01

    The study contains two parts. In the first part an analytical procedure is developed to logically and reproducibly subdivide the control room personnel tasks resulting in a list of the elements (operations) and the structure (operations scheme) of a task. The second part lists together all knowledge of and influences on human engineering which are known at this time and which should be taken into account in designing control rooms. The content of this catalogue can best be used and presented by using a personal computer. Two fundamental different ways are possible to use the catalogue. Designing new control rooms or new parts of control rooms the results of the task analysis which should be done first, should guide the search in the catalogue to find the right human engineering factors. For assessing existing control room panels the performance shaping factors which are establishing the table of content, permit a quick access to the catalogue. Both the specific procedure of the task analysis and the different ways of access to the catalogue of human engineering knowledge for designing nuclear power plant control rooms have been proven by experienced system engineers and safety experts. The results are presented. They have been considered in this version of the study. (orig.) [de

  14. Numerical and experimental study on temperature control of solar panels with form-stable paraffin/expanded graphite composite PCM

    International Nuclear Information System (INIS)

    Luo, Zigeng; Huang, Zhaowen; Xie, Ning; Gao, Xuenong; Xu, Tao; Fang, Yutang; Zhang, Zhengguo

    2017-01-01

    Highlights: • A passive cooling PV-PCM system was developed. • Form-stable paraffin/EG composite PCM with high thermal conductivity was utilized. • Numerical simulation on the temperature of PV-PCM panel was carried out. • Effects of density were studied under the given weather conditions. - Abstract: Performance of photovoltaic (PV) panels is greatly affected by its operating temperature. And traditional active and passive cooling methods usually suffer from the disadvantages of external energy consumption, uneven temperature distribution and low thermal conductivity of phase change materials (PCMs). In this work, a PV-PCM system was developed to control the temperature of a PV panel by applying high thermal conductive form-stable paraffin (ZDJN-28)/EG composite PCM. The temperature, output voltage and power of a conventional PV panel and the PV-PCM panel were measured and compared. A numerical simulation model established by CFD software FLUENT was used to simulate the temperature change process of the PV-PCM panel with different material densities under the same conditions as experiment. The experiment results showed that compared with the temperature of the conventional PV panel, the temperature of the PV-PCM panel is kept below 50 °C for 200 min extended by 146 min with output power averagely increased by 7.28% in heating process. Simulated temperatures were in good agreement with experimental temperatures and indicated that the higher the density of the PCM is, the better the temperature management performance the PV panel could achieve. Besides, the PCM with density of 900 kg/m 3 was found sufficient to achieve a good temperature management performance when the average ambient temperature below 25 °C with the highest solar irradiation of 901 w/m 2 . In summary, this work is of great importance in the design of a PV-PCM system for temperature management of PV panels.

  15. Absorptive coating for aluminum solar panels

    Science.gov (United States)

    Desmet, D.; Jason, A.; Parr, A.

    1979-01-01

    Method for coating forming coating of copper oxide from copper component of sheet aluminum/copper alloy provides strong durable solar heat collector panels. Copper oxide coating has solar absorption characteristics similar to black chrome and is much simpler and less costly to produce.

  16. Design of Flight Control Panel Layout using Graphical User Interface in MATLAB

    Science.gov (United States)

    Wirawan, A.; Indriyanto, T.

    2018-04-01

    This paper introduces the design of Flight Control Panel (FCP) Layout using Graphical User Interface in MATLAB. The FCP is the interface to give the command to the simulation and to monitor model variables while the simulation is running. The command accommodates by the FCP are altitude command, the angle of sideslip command, heading command, and setting command for turbulence model. The FCP was also designed to monitor the flight parameter while the simulation is running.

  17. Solar Panel based Milk Pasteurization

    DEFF Research Database (Denmark)

    Nielsen, Kirsten Mølgaard; Pedersen, Tom Søndergaard

    This paper treats the subject of analysis, design and development of the control system for a solar panel based milk pasteurization system to be used in small villages in Tanzania. The analysis deals with the demands for an acceptable pasteurization, the varying energy supply and the low cost, low...... complexity, simple user interface and high reliability demands. Based on these demands a concept for the pasteurization system is established and a control system is developed. A solar panel has been constructed and the energy absorption has been tested in Tanzania. Based on the test, the pasteurization...... system is dimensioned. A functional prototype of the pasteurization facility with a capacity of 200 l milk/hour has been developed and tested. The system is prepared for solar panels as the main energy source and is ready for a test in Tanzania....

  18. Solar Panel based Milk Pasteurization

    DEFF Research Database (Denmark)

    Nielsen, Kirsten Mølgaard; Pedersen, Tom Søndergaard

    2002-01-01

    This paper treats the subject of analysis, design and development of the control system for a solar panel based milk pasteurization system to be used in small villages in Tanzania. The analysis deals with the demands for an acceptable pasteurization, the varying energy supply and the low cost, low...... complexity, simple user interface and high reliability demands. Based on these demands a concept for the pasteurization system is established and a control system is developed. A solar panel has been constructed and the energy absorption has been tested in Tanzania. Based on the test, the pasteurization...... system is dimensioned. A functional prototype of the pasteurization facility with a capacity of 200 l milk/hour has been developed and tested. The system is prepared for solar panels as the main energy source and is ready for a test in Tanzania....

  19. Local panels and maintainability human factors assessment for AP1000 nuclear power plant

    International Nuclear Information System (INIS)

    Li, Zhonghai; Reed, Julie I.

    2011-01-01

    A document entitled 'AP1000 Local Panels and Maintainability Human Factors Design Guidelines' was produced to aid the designers to specifically include human factors (HF) considerations in the design, operation, and maintenance of local control stations and plant equipment. To ensure that the applicable HF design guidelines are appropriately applied to the design of local panels and maintenance activities, and identify any HF improvement opportunities that can readily be implemented at the design stage, a HF assessment of maintenance activities and local plant operations is underway. This assessment gives priority to local control stations and equipment which have been identified as having a potential impact on safety. This includes risk-significant systems, structures and components (SSCs) identified through the probabilistic risk assessment (PRA), and local operator actions as required by the Emergency Operating Procedures (EOPs). Local actions, maintenance activities and associated operator interfaces are reviewed against the relevant HF guidelines. The results of the assessment include a description of the component, associated local actions and/or required maintenance activities, good design features and/or potential issues, and recommendations for change or improvement. These results are communicated to responsible design engineers who evaluate the impact to plant design and implement design changes, if deemed necessary. (author)

  20. Control Systems of Rubber Dryer Machinery Components Using Programmable Logic Control (PLC)

    Science.gov (United States)

    Hendra; Yulianto, A. S.; Indriani, A.; Hernadewita; Hermiyetti

    2018-02-01

    Application of programmable logic control (PLC) is widely used on the control systems in the many field engineering such as automotive, aviation, food processing and other industries [1-2]. PLC is simply program to control many automatic activity, easy to use, flexible and others. PLC using the ladder program to solve and regulated the control system component. In previous research, PLC was used for control system of rotary dryer machine. In this paper PLC are used for control system of motion component in the rubber dryer machinery. Component of rubber dryer machine is motors, gearbox, sprocket, heater, drying chamber and bearing. Principle working of rubber dryer machinery is wet rubber moving into the drying chamber by sprocket. Sprocket is driven by motors that conducted by PLC to moving and set of wet rubber on the drying chamber. Drying system uses greenhouse effect by making hanger dryer design in the form of line path. In this paper focused on motion control system motors and sensors drying rubber using PLC. The results show that control system of rubber dryer machinery can work in accordance control input and the time required to dry the rubber.

  1. 76 FR 28790 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial review.

    Science.gov (United States)

    2011-05-18

    ... announced below concerns Affordable Care Act (ACA): Childhood Obesity Research Funding Opportunity... ``Affordable Care Act (ACA): Childhood Obesity Research Funding Opportunity Announcement (FOA) DP11-007, Panel... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease...

  2. Effects of personal experiences on the interpretation of the meaning of colours used in the displays and controls in electric control panels.

    Science.gov (United States)

    Lee, Inseok; Hwang, Won-Gue

    2015-01-01

    A survey was conducted to examine how personal experiences affect the interpretation of the meaning of display and control colours on electric control panels (ECPs). In Korea, the red light on ECPs represents a normal state of operation, while the green light represents a stopped state of operation; this appears to contradict the general stereotypes surrounding these colours. The survey results indicated that the participants who had experience in using ECPs interpreted the colour meaning differently from the other participant group. More than half of the experienced participants regarded the coloured displays and controls as they were designed, while most participants in the other group appeared to interpret the colours in accordance with the stereotypes. It is presumed that accidents related to human errors can occur when non-experienced people use the ECPs, which are easily accessible in many buildings. Practitioner Summary: A survey was conducted to investigate how personal experiences affect the interpretation of the function meanings of coloured lights on electrical control panels. It was found that the interpretation varies according to personal experiences, which can induce accidents related to human errors while operating electrical equipment.

  3. High temperature structural sandwich panels

    Science.gov (United States)

    Papakonstantinou, Christos G.

    High strength composites are being used for making lightweight structural panels that are being employed in aerospace, naval and automotive structures. Recently, there is renewed interest in use of these panels. The major problem of most commercial available sandwich panels is the fire resistance. A recently developed inorganic matrix is investigated for use in cases where fire and high temperature resistance are necessary. The focus of this dissertation is the development of a fireproof composite structural system. Sandwich panels made with polysialate matrices have an excellent potential for use in applications where exposure to high temperatures or fire is a concern. Commercial available sandwich panels will soften and lose nearly all of their compressive strength temperatures lower than 400°C. This dissertation consists of the state of the art, the experimental investigation and the analytical modeling. The state of the art covers the performance of existing high temperature composites, sandwich panels and reinforced concrete beams strengthened with Fiber Reinforced Polymers (FRP). The experimental part consists of four major components: (i) Development of a fireproof syntactic foam with maximum specific strength, (ii) Development of a lightweight syntactic foam based on polystyrene spheres, (iii) Development of the composite system for the skins. The variables are the skin thickness, modulus of elasticity of skin and high temperature resistance, and (iv) Experimental evaluation of the flexural behavior of sandwich panels. Analytical modeling consists of a model for the flexural behavior of lightweight sandwich panels, and a model for deflection calculations of reinforced concrete beams strengthened with FRP subjected to fatigue loading. The experimental and analytical results show that sandwich panels made with polysialate matrices and ceramic spheres do not lose their load bearing capability during severe fire exposure, where temperatures reach several

  4. Surface properties of thermally treated composite wood panels

    Science.gov (United States)

    Croitoru, Catalin; Spirchez, Cosmin; Lunguleasa, Aurel; Cristea, Daniel; Roata, Ionut Claudiu; Pop, Mihai Alin; Bedo, Tibor; Stanciu, Elena Manuela; Pascu, Alexandru

    2018-04-01

    Composite finger-jointed spruce and oak wood panels have been thermally treated under standard pressure and oxygen content conditions at two different temperatures, 180 °C and respectively 200 °C for short time periods (3 and 5 h). Due to the thermally-aided chemical restructuration of the wood components, a decrease in water uptake and volumetric swelling values with up to 45% for spruce and 35% for oak have been registered, comparing to the reference samples. In relation to water resistance, a 15% increase of the dispersive component of the surface energy has been registered for the thermal-treated spruce panels, which impedes water spreading on the surface. The thermal-treated wood presents superior resistance to accelerated UV exposure and subsequently, with up to 10% higher Brinell hardness values than reference wood. The proposed thermal treatment improves the durability of the finger-jointed wood through a more economically and environmental friendly method than traditional impregnation, with minimal degradative impact on the structural components of wood.

  5. Active control law design for flutter suppression and gust alleviation of a panel with piezoelectric actuators

    International Nuclear Information System (INIS)

    Ahmad Fazelzadeh, S; Mohammad Jafari, S

    2008-01-01

    This paper presents an active optimal integral/feedforward control for a supersonic panel under gust disturbance effects with piezoelectric actuators. Classical laminate theory with induced strain actuation and a generalized form of Hamilton's principle are used to formulate the governing equations of motion. The total charge developed on the sensor layer is calculated from the direct piezoelectric equation. The piezoelectric sensor distributed output is also integrated, since the output voltage is dependent on the integrated strain rates over the sensor area. Aerodynamic modeling is accomplished by first-order piston theory with gust velocity effects. The model reduction is performed to the state space system of equations for the control design and the time domain simulation. Moreover, the disturbance dynamics are modeled through the addition to the equations of motion for various conditions. The optimal control problem is set up to minimize the panel deflection using a linear quadratic regulator (LQR). Using an integral control model as a part of the feedback loop, together with a feedforward of the disturbances, greatly enhances the transient response, and the steady state error characteristics of this system are observed. Also, parametric studies for three piezoelectric actuator configurations are demonstrated. Simulation results show that the controller model is effective for flutter suppression and gust alleviation for various piezo configurations

  6. Advanced nuclear plant control complex

    International Nuclear Information System (INIS)

    Scarola, K.; Jamison, S.; Manazir, R.M.; Rescorl, R.L.; Harmon, D.L.

    1991-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system which is nuclear qualified for rapid response to changes in plant parameters and a component control system which together provide a discrete monitoring and control capability at a panel in the control room. A separate data processing system, which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs and a large, overhead integrated process status overview board. The discrete indicator and alarm system and the data processing system receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accidental conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof. (author)

  7. Diseño e implementación de un sistema fuzzy-pid pera el control del ángulo de inclinación del panel solar monocristalino de 30 watt

    OpenAIRE

    Recalde Regalado, Néstor Xavier; Prieto Briceño, Fernando Javier

    2014-01-01

    In the project the difference by putting a solar panel on static mode compared with a solar panel in dynamic mode, the dynamic mode solar panel system works with a Fuzzy-PID controller is implemented in a microcontroller is shown, this control system is to position the solar panel in a good position to take advantage of solar radiation and thus, it is possible to store the energy collected by the solar panel in a battery. En el proyecto se demuestra la diferencia que existe al colocar un p...

  8. 78 FR 19489 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): Initial Review

    Science.gov (United States)

    2013-04-01

    ... Increase Breast and Cervical Cancer Population--Based Prevention Activities SIP13-066, Panel A, initial... Colorectal Cancer Screening, SIP13-065; and Using Small Media to Increase Breast and Cervical Cancer... DEPARTMENT OF HEALTH AND HUMAN SERVICES Centers for Disease Control and Prevention Disease...

  9. Tracking and Control of Gas Turbine Engine Component Damage/Life

    Science.gov (United States)

    Jaw, Link C.; Wu, Dong N.; Bryg, David J.

    2003-01-01

    This paper describes damage mechanisms and the methods of controlling damages to extend the on-wing life of critical gas turbine engine components. Particularly, two types of damage mechanisms are discussed: creep/rupture and thermo-mechanical fatigue. To control these damages and extend the life of engine hot-section components, we have investigated two methodologies to be implemented as additional control logic for the on-board electronic control unit. This new logic, the life-extending control (LEC), interacts with the engine control and monitoring unit and modifies the fuel flow to reduce component damages in a flight mission. The LEC methodologies were demonstrated in a real-time, hardware-in-the-loop simulation. The results show that LEC is not only a new paradigm for engine control design, but also a promising technology for extending the service life of engine components, hence reducing the life cycle cost of the engine.

  10. Electrohydraulic Forming of Near-Net Shape Automotive Panels

    Energy Technology Data Exchange (ETDEWEB)

    Golovaschenko, Sergey F.

    2013-09-26

    The objective of this project was to develop the electrohydraulic forming (EHF) process as a near-net shape automotive panel manufacturing technology that simultaneously reduces the energy embedded in vehicles and the energy consumed while producing automotive structures. Pulsed pressure is created via a shockwave generated by the discharge of high voltage capacitors through a pair of electrodes in a liquid-filled chamber. The shockwave in the liquid initiated by the expansion of the plasma channel formed between two electrodes propagates towards the blank and causes the blank to be deformed into a one-sided die cavity. The numerical model of the EHF process was validated experimentally and was successfully applied to the design of the electrode system and to a multi-electrode EHF chamber for full scale validation of the process. The numerical model was able to predict stresses in the dies during pulsed forming and was validated by the experimental study of the die insert failure mode for corner filling operations. The electrohydraulic forming process and its major subsystems, including durable electrodes, an EHF chamber, a water/air management system, a pulse generator and integrated process controls, were validated to be capable to operate in a fully automated, computer controlled mode for forming of a portion of a full-scale sheet metal component in laboratory conditions. Additionally, the novel processes of electrohydraulic trimming and electrohydraulic calibration were demonstrated at a reduced-scale component level. Furthermore, a hybrid process combining conventional stamping with EHF was demonstrated as a laboratory process for a full-scale automotive panel formed out of AHSS material. The economic feasibility of the developed EHF processes was defined by developing a cost model of the EHF process in comparison to the conventional stamping process.

  11. Law Panel in action.

    Science.gov (United States)

    Odulana, J

    In September 1976 the Africa Regional Council (ARC) of IPPF created a Law Panel to 1) advise the ARC on the emphasis of laws and parenthood programs in the region, 2) investigate legal obstacles to family planning and ways of removing them, 3) institute a monitoring service on laws and court decisions affecting planned parenthood, and 4) prepare a list of lawyers and legal reformers by country. The panel has 1) recommended adoption of an IPPF Central Medical Committee and Central Law Panel statement on sterilization, adolescent fertility control, and the use of medical and auxiliary personnel in family planning services with guidelines for Africa; 2) appointed National Legal Correspondents to carry on the monitoring service mentioned above in 18 countries; and 3) discussed solutions to problems in delivering family planning services with family planning associations in Tanzania, Zambia, Mauritius, Madagascar, and Kenya. Laws governing family planning education and services, marriage, divorce, and maternity benefits in these countries are summarized. In 1978 the panel will hold 2 workshops on law and the status of women.

  12. Components inspection of Monju, a sodium bonded type control rod

    International Nuclear Information System (INIS)

    Harada, Kiyoshi; Matsushita, Yuichi; Lee, Chunchan; Abe, Hideaki; Watahiki, Naohisa

    2002-03-01

    This Report addresses a result of a sodium test conducted on components of a Double Poral Filter Sodium Bonded Type Control Rod that is expected to be a next generation, long life Control Rod. Upper and lower Poral Filter Sodium Bonded Type Control Rod components were mocked up to conduct a sodium test. During the test, sodium chargeability, formation of Gas Plenum at the upper part of the components, sodium drain-ability and NaOH clean-ability were recognized under actual plant condition. The following are results obtained: (1) Sodium Chargeability at Control Rod Insertion to EVST. Sodium was charged into the components when the mocked-up was inserted in sodium of 190degC, with insertion speed of 6 m/min which is an actual insertion speed to EVST. (2) Formation of Upper Gas Plenum by Helium Gas generated in Control Rod Components Gas Plenum formation within deviation of 9% was confirmed by releasing helium gas into the mocked-up which is immersed in sodium of 620degC and 190degC. Length of Gas Plenum is confirmed to be retained in certain length even if helium gas is further released into formed Gas Plenum. (3) Sodium Drain-ability of Control Rod Components when Drawing from EVST. Drain-ability was confirmed to be sufficient and no sodium residue was found in the mocked-up when the mocked-up was drawn out from sodium of 190degC, with drawing speed of 6 m/min which is an actual drawing speed from EVST. (4) Clean-ability of NaOH Solution against Sodium Residue in Control Rod Components. Sodium and NaOH solution reacted calmly, however, clean-ability was not sufficient. When Sodium fully remained in Control Rod Components, it made circulation of NaOH solution not enough. (author)

  13. Use of Industrial Components in SL/BT Equipment Controls

    CERN Document Server

    Carlier, E

    1999-01-01

    The control system of all SPS target stations, beam absorbers and other aperture limiting devices is presently being refurbished, using solely standard industrial hardware and software components. SIEMENS Simatic S7-300 programmable logic controllers serve as equipment controllers. They are connected through Profibus to a WinNT front-end running the SIEMENS WinCC SCADA package which acts as local controller and gateway for remote access. A variant configuration, where the PLCs are directly linked to Ethernet, has been used for controlling the SPS Q measurement kickers. These and some other SL/BT projects will be reviewed where fully off-the-shelf components have been successfully integrated into the SL accelerator controls infrastructure. The arguments leading to the various technical choices will be laid down including a report of the experience gained. Finally, the presentation will address the perspective and current ideas for using industrial components in controlling SL/BT equipment during the LHC era.

  14. Thermal Modeling of the Mars Reconnaissance Orbiter's Solar Panel and Instruments during Aerobraking

    Science.gov (United States)

    Dec, John A.; Gasbarre, Joseph F.; Amundsen, Ruth M.

    2007-01-01

    The Mars Reconnaissance Orbiter (MRO) launched on August 12, 2005 and started aerobraking at Mars in March 2006. During the spacecraft s design phase, thermal models of the solar panels and instruments were developed to determine which components would be the most limiting thermally during aerobraking. Having determined the most limiting components, thermal limits in terms of heat rate were established. Advanced thermal modeling techniques were developed utilizing Thermal Desktop and Patran Thermal. Heat transfer coefficients were calculated using a Direct Simulation Monte Carlo technique. Analysis established that the solar panels were the most limiting components during the aerobraking phase of the mission.

  15. A panel of 74 AISNPs: Improved ancestry inference within Eastern Asia.

    Science.gov (United States)

    Li, Cai-Xia; Pakstis, Andrew J; Jiang, Li; Wei, Yi-Liang; Sun, Qi-Fan; Wu, Hong; Bulbul, Ozlem; Wang, Ping; Kang, Long-Li; Kidd, Judith R; Kidd, Kenneth K

    2016-07-01

    Many ancestry informative SNP (AISNP) panels have been published. Ancestry resolution in them varies from three to eight continental clusters of populations depending on the panel used. However, none of these panels differentiates well among East Asian populations. To meet this need, we have developed a 74 AISNP panel after analyzing a much larger number of SNPs for Fst and allele frequency differences between two geographically close population groups within East Asia. The 74 AISNP panel can now distinguish at least 10 biogeographic groups of populations globally: Sub-Saharan Africa, North Africa, Europe, Southwest Asia, South Asia, North Asia, East Asia, Southeast Asia, Pacific and Americas. Compared with our previous 55-AISNP panel, Southeast Asia and North Asia are two newly assignable clusters. For individual ancestry assignment, the likelihood ratio and ancestry components were analyzed on a different set of 500 test individuals from 11 populations. All individuals from five of the test populations - Yoruba (YRI), European (CEU), Han Chinese in Henan (CHNH), Rondonian Surui (SUR) and Ticuna (TIC) - were assigned to their appropriate geographical regions unambiguously. For the other test populations, most of the individuals were assigned to their self-identified geographical regions with a certain degree of overlap with adjacent populations. These alternative ancestry components for each individual thus help give a clearer picture of the possible group origins of the individual. We have demonstrated that the new AISNP panel can achieve a deeper resolution of global ancestry. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Online market research panel members as controls in case-control studies to investigate gastrointestinal disease outbreaks: early experiences and lessons learnt from the UK.

    Science.gov (United States)

    Mook, P; McCormick, J; Kanagarajah, S; Adak, G K; Cleary, P; Elson, R; Gobin, M; Hawker, J; Inns, T; Sinclair, C; Trienekens, S C M; Vivancos, R; McCarthy, N D

    2018-03-01

    Established methods of recruiting population controls for case-control studies to investigate gastrointestinal disease outbreaks can be time consuming, resulting in delays in identifying the source or vehicle of infection. After an initial evaluation of using online market research panel members as controls in a case-control study to investigate a Salmonella outbreak in 2013, this method was applied in four further studies in the UK between 2014 and 2016. We used data from all five studies and interviews with members of each outbreak control team and market research panel provider to review operational issues, evaluate risk of bias in this approach and consider methods to reduce confounding and bias. The investigators of each outbreak reported likely time and cost savings from using market research controls. There were systematic differences between case and control groups in some studies but no evidence that conclusions on the likely source or vehicle of infection were incorrect. Potential selection biases introduced by using this sampling frame and the low response rate are unclear. Methods that might reduce confounding and some bias should be balanced with concerns for overmatching. Further evaluation of this approach using comparisons with traditional methods and population-based exposure survey data is recommended.

  17. Attitude dynamics and control of spacecraft with a partially filled liquid tank and flexible panels

    Science.gov (United States)

    Liu, Feng; Yue, Baozeng; Zhao, Liangyu

    2018-02-01

    A liquid-filled flexible spacecraft is essentially a time-variant fully-coupled system, whose dynamics characteristics are closely associated with its motion features. This paper focuses on the mathematical modelling and attitude control of the spacecraft coupled with fuel sloshing dynamics and flexible solar panels vibration. The slosh motion is represented by a spherical pendulum, whose motion description method is improved by using split variable operation. Benefiting from this improvement, the nonlinear lateral sloshing and the rotary sloshing as well as the rigid motion of a liquid respect to the spacecraft can be approximately described. The assumed modes discretization method has been adopted to approximate the elastic displacements of the attached panels, and the coupled dynamics is derived by using the Lagrangian formulation. A variable substitution method is proposed to obtain the apparently-uncoupled mathematical model of the rigid-flexible-liquid spacecraft. After linearization, this model can be directly used for designing Lyapunov output-feedback attitude controller (OFAC). With only torque actuators, and attitude and rate sensors installed, this kind of attitude controller, as simulation results show, is capable of not only bringing the spacecraft to the desired orientation, but also suppressing the effect of flex and slosh on the attitude motion of the spacecraft.

  18. Low frequency noise as a control test for spacial solar panels

    Science.gov (United States)

    Orsal, B.; Alabedra, R.; Ruas, R.

    1986-07-01

    The present study of low frequency noise in a forward-biased dark solar cell, in order to develop an NDE test method for solar panels, notes that a single cell with a given defect is thus detectable under dark conditions. The test subject was a space solar panel consisting of five cells in parallel and five in series; these cells are of the n(+)-p monocrystalline Si junction type. It is demonstrated that the noise associated with the defective cell is 10-15 times higher than that of a good cell. Replacement of a good cell by a defective one leads to a 30-percent increase in the noise level of the panel as a whole.

  19. Technical advisory panel for the large acceptance spectrometer: Final report

    International Nuclear Information System (INIS)

    1989-01-01

    The Technical Advisory Panel for the Large Acceptance Spectrometer met on November 17--19, 1988, at CEBAF to perform a second review of the status of this project. The charge to the Panel was ''to provide technical advice to the CEBAF directorate on the design, construction, cost, schedule, and implementation of the Large Acceptance Spectrometer.'' In this written report, an overview of the entire project is given. Specific comments on the major components, data handling and analysis, assembly and installation, and management are presented. The Panel's conclusions are contained in the Executive Summary at the beginning of the report

  20. Damage tolerant evaluation of cracked stiffened panels under ...

    Indian Academy of Sciences (India)

    Stiffened panels; stress intensity factor; fatigue and fracture; damage .... Extensive work on fracture analysis of structural components was carried out by using the ... respectively), in view of the transformation matrices related to MQL9S2 FE.

  1. Low frequency noise reduction using stiff light composite panels

    Institute of Scientific and Technical Information of China (English)

    DENG Yongchang; LIN Weizheng

    2003-01-01

    The experiment presented in this paper is to investigate and analyze the noise reduction at low frequency using stiff light composite panels. Since these composite panels are made of lightweight and stiff materials, this actuation strategy will enable the creation of composite panels for duct noise control without using traditional heavy structural mass. The results suggest that the mass-spring resonance absorption in the case of a comparatively stiff thick panel with a thin flexible plate is more efficient with minimum weight, when subjected to low-frequency (<500 Hz). The efficiency of the panel absorber depends on the mass of the thin flexible plate and the stiffness of the panel.

  2. Manufacturing technology development for vacuum vessel and plasma facing components

    International Nuclear Information System (INIS)

    Laitinen, Arttu; Liimatainen, Jari; Hallila, Pentti

    2005-01-01

    Vacuum vessel and plasma facing components of the ITER construction including shield modules and primary first wall panels have great impact on the production costs and reliability of the installation. From the manufacturing technology point of view, accuracy of shape, properties of the various austenitic stainless steel/austenitic stainless steel interfaces or CuCrZr/austenitic stainless steel interfaces as well as those of the base materials are crucial for technical reliability of the construction. The current approach in plasma facing components has been utilisation of solid-HIP technology and solid-powder-HIP technology. Due to the large size of especially shield modules shape, control of the internal cavities and cooling channels is extremely demanding. This requires strict control of the raw materials and manufacturing parameters

  3. A controlled method to flatten warped wooden panels

    NARCIS (Netherlands)

    Van Gerven, G.; Ankersmit, B.; van Duin, P.H.J.C.; Jorissen, A.J.M.; Schellen, H.L.

    2016-01-01

    This article describes the research and subsequent treatment to flatten the warped wooden doors of a seventeenth-century cabinet. The aim was to flatten the veneered panels, in very strict climatic conditions and without lifting any veneer or damaging the surface finish of the exterior. In this

  4. Analyses results of the EHF FW Panel with welded fingers

    International Nuclear Information System (INIS)

    Sviridenko, M.N.; Leshukov, A.Yu.; Razmerov, A.V.; Tomilov, S.N.; Danilov, I.V.; Strebkov, Yu.S.; Mazul, I.V.; Labusov, A.; Gervash, A.A.; Belov, A.V.; Semichev, D.

    2014-01-01

    Highlights: • The design of FW panel with welded fingers has been developed. • The FW panel with welded fingers has been analyzed. • The pressure drop in FW panel coolant path do not exceed allowable one. • The mass flow rate distribution between finger pairs are on acceptable level. • Temperatures in FW components do not exceed allowable one. - Abstract: According to Procurement Arrangement (PA) Russian Federation will procure 40% of enhanced heat flux first wall (FW) panels. The signing of PA is scheduled on November 2013. In framework of PA preparation the RF specialists perform EHF FW design optimization in order to provide the ability to operation of EHF FW panel under ITER conditions. This article contains the design description of EHF FW 14 developed by RF and following analysis have been performed: • Hydraulic analysis; • Transient thermal analysis; • Structural analysis. Analyses results show that new design of FW panel with two straight welds for finger fixation on FW beam developed by RF specialists can be used as a reference design for ITER blanket EHF FW panel loaded by 5 MW/m 2 peak heat flux

  5. A thermal model for photovoltaic panels under varying atmospheric conditions

    International Nuclear Information System (INIS)

    Armstrong, S.; Hurley, W.G.

    2010-01-01

    The response of the photovoltaic (PV) panel temperature is dynamic with respect to the changes in the incoming solar radiation. During periods of rapidly changing conditions, a steady state model of the operating temperature cannot be justified because the response time of the PV panel temperature becomes significant due to its large thermal mass. Therefore, it is of interest to determine the thermal response time of the PV panel. Previous attempts to determine the thermal response time have used indoor measurements, controlling the wind flow over the surface of the panel with fans or conducting the experiments in darkness to avoid radiative heat loss effects. In real operating conditions, the effective PV panel temperature is subjected to randomly varying ambient temperature and fluctuating wind speeds and directions; parameters that are not replicated in controlled, indoor experiments. A new thermal model is proposed that incorporates atmospheric conditions; effects of PV panel material composition and mounting structure. Experimental results are presented which verify the thermal behaviour of a photovoltaic panel for low to strong winds.

  6. Supersonic flutter suppression of electrorheological fluid-based adaptive panels resting on elastic foundations using sliding mode control

    International Nuclear Information System (INIS)

    Hasheminejad, Seyyed M; Nezami, M; Aryaee Panah, M E

    2012-01-01

    Brief reviews on suppressing panel flutter vibrations by various active control strategies as well as utilization tunable electrorheological fluids (ERFs) for vibration control of structural systems are presented. Active suppression of the supersonic flutter motion of a simply supported sandwich panel with a tunable ERF interlayer, and coupled to an elastic foundation, is subsequently investigated. The structural formulation is based on the classical beam theory along with the Winkler–Pasternak foundation model, the ER fluid core is modeled as a first-order Kelvin–Voigt material, and the quasi-steady first-order supersonic piston theory is employed to describe the aerodynamic loading. Hamilton’s principle is used to derive a set of fully coupled dynamic equations of motion. The generalized Fourier expansions in conjunction with the Galerkin method are then employed to formulate the governing equations in the state space domain. The critical dynamic pressures at which unstable panel oscillations (coalescence of eigenvalues) occur are obtained via the p-method for selected applied electric field strengths (E = 0,2,4 kV mm −1 ). The classical Runge–Kutta time integration algorithm is subsequently used to calculate the open-loop aeroelastic response of the system in various basic loading configurations (i.e. uniformly distributed blast, gust, sonic boom, and step loads), with or without an interacting soft/stiff elastic foundation. Finally, a sliding mode control synthesis (SMC) involving the first six natural modes of the structural system is set up to actively suppress the closed-loop system response in supersonic flight conditions and under the imposed excitations. Simulation results demonstrate performance, effectiveness, and insensitivity with respect to the spillover of the proposed SMC-based control system. Limiting cases are considered and good agreements with the data available in the literature as well as with the computations made by using the

  7. Panel Analysis

    DEFF Research Database (Denmark)

    Brænder, Morten; Andersen, Lotte Bøgh

    2014-01-01

    Based on our 2013-article, ”Does Deployment to War Affect Soldiers' Public Service Motivation – A Panel Study of Soldiers Before and After their Service in Afghanistan”, we present Panel Analysis as a methodological discipline. Panels consist of multiple units of analysis, observed at two or more...... in research settings where it is not possible to distribute units of analysis randomly or where the independent variables cannot be manipulated. The greatest disadvantage in regard to using panel studies is that data may be difficult to obtain. This is most clearly vivid in regard to the use of panel surveys...... points in time. In comparison with traditional cross-sectional studies, the advantage of using panel studies is that the time dimension enables us to study effects. Whereas experimental designs may have a clear advantage in regard to causal inference, the strength of panel studies is difficult to match...

  8. Evaluation of a Serum Lung Cancer Biomarker Panel.

    Science.gov (United States)

    Mazzone, Peter J; Wang, Xiao-Feng; Han, Xiaozhen; Choi, Humberto; Seeley, Meredith; Scherer, Richard; Doseeva, Victoria

    2018-01-01

    A panel of 3 serum proteins and 1 autoantibody has been developed to assist with the detection of lung cancer. We aimed to validate the accuracy of the biomarker panel in an independent test set and explore the impact of adding a fourth serum protein to the panel, as well as the impact of combining molecular and clinical variables. The training set of serum samples was purchased from commercially available biorepositories. The testing set was from a biorepository at the Cleveland Clinic. All lung cancer and control subjects were >50 years old and had smoked a minimum of 20 pack-years. A panel of biomarkers including CEA (carcinoembryonic antigen), CYFRA21-1 (cytokeratin-19 fragment 21-1), CA125 (carbohydrate antigen 125), HGF (hepatocyte growth factor), and NY-ESO-1 (New York esophageal cancer-1 antibody) was measured using immunoassay techniques. The multiple of the median method, multivariate logistic regression, and random forest modeling was used to analyze the results. The training set consisted of 604 patient samples (268 with lung cancer and 336 controls) and the testing set of 400 patient samples (155 with lung cancer and 245 controls). With a threshold established from the training set, the sensitivity and specificity of both the 4- and 5-biomarker panels on the testing set was 49% and 96%, respectively. Models built on the testing set using only clinical variables had an area under the receiver operating characteristic curve of 0.68, using the biomarker panel 0.81 and by combining clinical and biomarker variables 0.86. This study validates the accuracy of a panel of proteins and an autoantibody in a population relevant to lung cancer detection and suggests a benefit to combining clinical features with the biomarker results.

  9. Acceptance/Operational Test Report for Tank 241-AN-104 camera and camera purge control system

    International Nuclear Information System (INIS)

    Castleberry, J.L.

    1995-11-01

    This Acceptance/Operational Test Procedure (ATP/OTP) will document the satisfactory operation of the camera purge panel, purge control panel, color camera system and associated control components destined for installation. The final acceptance of the complete system will be performed in the field. The purge panel and purge control panel will be tested for its safety interlock which shuts down the camera and pan-and-tilt inside the tank vapor space during loss of purge pressure and that the correct purge volume exchanges are performed as required by NFPA 496. This procedure is separated into seven sections. This Acceptance/Operational Test Report documents the successful acceptance and operability testing of the 241-AN-104 camera system and camera purge control system

  10. Data acquisition and control for LMFBR component testing

    International Nuclear Information System (INIS)

    Turner, G.E.

    1983-01-01

    Liquid Metal Fast Breeder Reactor components such as pumps, steam generators, and piping components are tested for their ability to withstand expected thermal transients of up to 25 0 F/s (14 0 C/s). The Energy Technology Engineering Center performs these tests in facilities specifically designed for that purpose. Although much of the instrumentation and controls for these test facilities are similar to those used in conventional process plants, the requirement to produce, control, and measure the effects of rapid thermal transients results in some not-so-conventional data acquisition and control system design criteria. This paper describes a typical data-acquisition system used at one of the ETEC test facilities and how the thermal transients are produced and controlled in the pump and steam-generator test facilities

  11. A Study on Large Display Panel Design for the Countermeasures against Team Errors within the Main Control Room of APR-1400

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sa Kil; Lee, Yong Hee [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    The personal aspect of human errors has been mainly overcome by virtue of the education and training. However, in the system aspect, the education and training system needs to be reconsidered for more effective reduction of human errors affected from various systems hazards. Traditionally the education and training systems are mainly not focused on team skills such as communication, situational awareness, and coordination, etc. but individual knowledge, skill, and attitude. However, the team factor is one of the crucial issues to reduce the human errors in most industries. In this study, we identify the emerging types of team errors, especially, in digitalized control room of nuclear power plants such as the APR-1400 main control room. Most works in nuclear industry are to be performed by a team of more than two persons. Even though the individual errors can be detected and recovered by the qualified others and/or the well trained team, it is rather seldom that the errors by team could be easily detected and properly recovered by the team itself. Note that the team is defined as two or more people who are appropriately interacting with each other, and the team is a dependent aggregate, which accomplishes a valuable goal. Team error is one of the typical organizational errors that may occur during performing operations in nuclear power plants. The large display panel is a representative feature of digitalized control room. As a group-view display, the large display panel provides plant overview to the operators. However, in terms of team performance and team errors, the large display panel is on a discussion board still because the large display panel was designed just a concept of passive display. In this study, we will propose revised large display panel which is integrated with several alternative interfaces against feasible team errors.

  12. A Study on Large Display Panel Design for the Countermeasures against Team Errors within the Main Control Room of APR-1400

    International Nuclear Information System (INIS)

    Kim, Sa Kil; Lee, Yong Hee

    2015-01-01

    The personal aspect of human errors has been mainly overcome by virtue of the education and training. However, in the system aspect, the education and training system needs to be reconsidered for more effective reduction of human errors affected from various systems hazards. Traditionally the education and training systems are mainly not focused on team skills such as communication, situational awareness, and coordination, etc. but individual knowledge, skill, and attitude. However, the team factor is one of the crucial issues to reduce the human errors in most industries. In this study, we identify the emerging types of team errors, especially, in digitalized control room of nuclear power plants such as the APR-1400 main control room. Most works in nuclear industry are to be performed by a team of more than two persons. Even though the individual errors can be detected and recovered by the qualified others and/or the well trained team, it is rather seldom that the errors by team could be easily detected and properly recovered by the team itself. Note that the team is defined as two or more people who are appropriately interacting with each other, and the team is a dependent aggregate, which accomplishes a valuable goal. Team error is one of the typical organizational errors that may occur during performing operations in nuclear power plants. The large display panel is a representative feature of digitalized control room. As a group-view display, the large display panel provides plant overview to the operators. However, in terms of team performance and team errors, the large display panel is on a discussion board still because the large display panel was designed just a concept of passive display. In this study, we will propose revised large display panel which is integrated with several alternative interfaces against feasible team errors

  13. Buckling and postbuckling of composite panels with cutouts subjected to combined edge shear and temperature change

    Science.gov (United States)

    Noor, Ahmed K.; Kim, Yong H.

    1995-01-01

    The results of a detailed study of the buckling and postbuckling responses of composite panels with central circular cutouts are presented. The panels are subjected to combined edge shear and temperature change. The panels are discretized by using a two-field degenerate solid element with each of the displacement components having a linear variation throughout the thickness of the panel. The fundamental unknowns consist of the average mechanical strains through the thickness and the displacement components. The effects of geometric nonlinearities and laminated anisotropic material behavior are included. The stability boundary, postbuckling response and the hierarchical sensitivity coefficients are evaluated. The hierarchical sensitivity coefficients measure the sensitivity of the buckling and postbuckling responses to variations in the panel stiffnesses, and the material properties of both the individual layers and the constituents (fibers and matrix). Numerical results are presented for composite panels with central circular cutouts subjected to combined edge shear and temperature change, showing the effects of variations in the hole diameter, laminate stacking sequence and fiber orientation, on the stability boundary and postbuckling response and their sensitivity to changes in the various panel parameters.

  14. Mechanical evaluation with fe analysis of sandwich panels for wind turbine blade

    Energy Technology Data Exchange (ETDEWEB)

    Yasaswi, M.; Naveen, P.N.E.; Prasad, R.V. [GIET. Dept. of Mechanical Engineering, Rajahmundry (India)

    2012-07-01

    Sandwich panels are notable for their structural efficiency and are used as load bearing components in various branches of engineering, especially in aerospace and marine industries. The objective of the present work is to perform computer-aided analysis on sandwich panels. The analysis of sandwich panel with truss core are compared with other four types of sandwich panel with continuous corrugated core, top hat core, zed core and channel core. The basic reason to use sandwich structure is to save weight, however smooth skins and excellent fatigue resistance are also attributes of a sandwich structure. A sandwich is comprised of two layered composite materials formed by bonding two or more thin facings or face sheets to relatively thick core materials. In this type of construction the facings resist nearly all of the in-plane loads and out-of-plane bending moments. The thin facings provide nearly all of the bending stiffness because they are generally of a much higher modulus material is located at a greatest distance from the neutral axis of the component. The basic concept of sandwich panel is that the facings carry the bending loads and the core carries the shear loads. The main function of the core material is to distribute local loads and stresses over large areas. From all this analysis it is concluded that the truss core Sandwich panels can be used in wind turbine blade design. (Author)

  15. 75 FR 13560 - Disease, Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): RFA DD 10...

    Science.gov (United States)

    2010-03-22

    ..., Disability, and Injury Prevention and Control Special Emphasis Panel (SEP): RFA DD 10-002 Public Health Research on Spina Bifida, RFA DD 10-003 Public Health Research on Children and Adults Living With Spina Bifida, RFA DD 10-004 Developing a Prospective Assessment of the Development, Health, and Condition...

  16. Improvement of transmission loss of a double panel by using active control with a virtual modal mass

    OpenAIRE

    Lhuillier , Vincent; Chesné , Simon; Gaudiller , Luc; Pezerat , Charles

    2013-01-01

    International audience; In this article, modal feedback control is proposed to reduce the sound transmission through finite double panels using lead zirconate titanate ceramic sensors and actuators bonded to the structure. Active control allows adding virtual modal damping and mass to the structure by the use of modal velocities and accelerations. In a first step, the equations describing the structure, the actuators, the acoustic excitation, and the acoustic radiation are detailed. Next, the...

  17. Investigation on Wall Panel Sandwiched With Lightweight Concrete

    Science.gov (United States)

    Lakshmikandhan, K. N.; Harshavardhan, B. S.; Prabakar, J.; Saibabu, S.

    2017-08-01

    The rapid population growth and urbanization have made a massive demand for the shelter and construction materials. Masonry walls are the major component in the housing sector and it has brittle characteristics and exhibit poor performance against the uncertain loads. Further, the structure requires heavier sections for carrying the dead weight of masonry walls. The present investigations are carried out to develop a simple, lightweight and cost effective technology for replacing the existing wall systems. The lightweight concrete is developed for the construction of sandwich wall panel. The EPS (Expanded Polystyrene) beads of 3 mm diameter size are mixed with concrete and developed a lightweight concrete with a density 9 kN/m3. The lightweight sandwich panel is cast with a lightweight concrete inner core and ferrocement outer skins. This lightweight wall panel is tested for in-plane compression loading. A nonlinear finite element analysis with damaged plasticity model is carried out with both material and geometrical nonlinearities. The experimental and analytical results were compared. The finite element study predicted the ultimate load carrying capacity of the sandwich panel with reasonable accuracy. The present study showed that the lightweight concrete is well suitable for the lightweight sandwich wall panels.

  18. EFSA NDA Panel (EFSA Panel on Dietetic Products, Nutrition and Allergies), 2014. Scientific Opinion on Dietary Reference Values for pantothenic acid

    DEFF Research Database (Denmark)

    Tetens, Inge

    2014-01-01

    Following a request from the European Commission, the Panel on Dietetic Products, Nutrition and Allergies (NDA) derived Dietary Reference Values (DRVs) for pantothenic acid. Pantothenic acid is a water-soluble vitamin, which is a component of coenzyme A (CoA) and acyl-carrier proteins. Pantothenic...

  19. Protection efficacy of gloves against components of the solvent in a sprayed isocyanate coating utilizing a reciprocating permeation panel.

    Science.gov (United States)

    Ceballos, Diana M; Reeb-Whitaker, Carolyn; Sasakura, Miyoko; Dills, Russell; Yost, Michael G

    2015-04-01

    Determine protection effectiveness of 5-mil natural rubber latex (0.13-mm), 5-mil nitrile rubber (0.13-mm), and 13-mil butyl rubber (0.33-mm) glove materials against solvents present in a commonly used automotive clear coat formulation using a novel permeation panel. The latex and nitrile gloves were the type commonly used by local autobody spray painters. Glove materials were tested by spraying an automotive clear coat onto an automated reciprocating permeation panel (permeation panel II). Temperature, relative humidity, and spray conditions were controlled to optimize clear coat loading homogeneity as evaluated by gravimetric analysis. Solvent permeation was measured using charcoal cloth analyzed by the National Institute for Occupational Safety and Health 1501 method. Natural rubber latex allowed 3-5 times the permeation of solvents relative to nitrile rubber for all 10 solvents evaluated: ethyl benzene, 2-heptanone, 1-methoxy-2-propyl acetate, o-xylene, m-xylene, p-xylene, n-butyl acetate, methyl isobutyl ketone, petroleum distillates, and toluene. There is a distinct behavior in solvent permeation before and after the coating dry time. Solvent permeation increased steadily before coating dry time and remained fairly constant after coating dry time. Butyl was not permeated by any of the solvents under the conditions tested. Commonly used 5-mil thick (0.13-mm) latex and nitrile gloves were ineffective barriers to solvents found in a commonly used clear coat formulation. Conversely, 13-mil (0.33-mm) butyl gloves were found to be protective against all solvents in the clear coat formulation. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  20. Reliability analysis and component functional allocations for the ESF multi-loop controller design

    International Nuclear Information System (INIS)

    Hur, Seop; Kim, D.H.; Choi, J.K.; Park, J.C.; Seong, S.H.; Lee, D.Y.

    2006-01-01

    This paper deals with the reliability analysis and component functional allocations to ensure the enhanced system reliability and availability. In the Engineered Safety Features, functionally dependent components are controlled by a multi-loop controller. The system reliability of the Engineered Safety Features-Component Control System, especially, the multi-loop controller which is changed comparing to the conventional controllers is an important factor for the Probability Safety Assessment in the nuclear field. To evaluate the multi-loop controller's failure rate of the k-out-of-m redundant system, the binomial process is used. In addition, the component functional allocation is performed to tolerate a single multi-loop controller failure without the loss of vital operation within the constraints of the piping and component configuration, and ensure that mechanically redundant components remain functional. (author)

  1. Diamond turning machine controller implementation

    Energy Technology Data Exchange (ETDEWEB)

    Garrard, K.P.; Taylor, L.W.; Knight, B.F.; Fornaro, R.J.

    1988-12-01

    The standard controller for a Pnuemo ASG 2500 Diamond Turning Machine, an Allen Bradley 8200, has been replaced with a custom high-performance design. This controller consists of four major components. Axis position feedback information is provided by a Zygo Axiom 2/20 laser interferometer with 0.1 micro-inch resolution. Hardware interface logic couples the computers digital and analog I/O channels to the diamond turning machine`s analog motor controllers, the laser interferometer, and other machine status and control information. It also provides front panel switches for operator override of the computer controller and implement the emergency stop sequence. The remaining two components, the control computer hardware and software, are discussed in detail below.

  2. Design approach of soft control system for implementation of advanced MMI in KNGR

    International Nuclear Information System (INIS)

    Kim, J. K.; Choi, M. J.; Choe, I. N.

    1999-01-01

    To overcome the inherent inflexibility of spatially dedicated man-machine interface (MMI) in conventional control room, computer based MMI technologies, along with compact workstation concept, are adopted in KNGR control room target design. In order to achieve the compact workstation design, a large number of spatially dedicated control switches and manual/auto stations in a traditional control room have to be replaced by a few common multi-function devices. These control devices, so called Soft Control System, consist of a personal computer based Flat Panel Display (FPD) device with touch sensitive screen which provides control MMI for the component selected among a number of plant components. Soft Control System is MMI device to allow control of continuous and discrete control device from single panel device. Soft Control System allows a standard interface device to assume the role of numerous control switch and analog control devices via software configuration. This has the advantage of following operator access to all plant control from a single control compact workstation. (author)

  3. The genetic component of preeclampsia

    DEFF Research Database (Denmark)

    Hansen, Anette Tarp; Bernth Jensen, Jens Magnus; Hvas, Anne-Mette

    2018-01-01

    Preeclampsia is a major cause of maternal and perinatal deaths. The aetiology of preeclampsia is largely unknown but a polygenetic component is assumed. To explore this hypothesis, we performed an in-depth whole-exome sequencing study in women with (cases, N = 50) and without (controls, N = 50......) preeclampsia. The women were identified in an unselected cohort of 2,545 pregnant women based on data from the Danish National Patient Registry and the Medical Birth Registry. Matching DNA was obtained from a biobank containing excess blood from routine antenatal care visits. Novogene performed the whole......-exome sequencing blinded to preeclampsia status. Variants for comparison between cases and controls were filtered in the Ingenuity Variant Analysis software. We applied two different strategies; a disease association panel approach, which included variants in single genes associated with established clinical risk...

  4. Investigation on a short circuit of large-area OLED lighting panels

    International Nuclear Information System (INIS)

    Park, J W; Kim, T W; Park, J B

    2013-01-01

    A short circuit often arises from large-area organic light-emitting device (OLED) lighting panels due to particles (i.e. dust, organic or metal debris) or the spike-like surface of the indium–tin–oxide (ITO) anode. On the emergence of a short circuit, an instant current crowding occurs, thereby reducing substantially the resistance of the panels and causing a failure of a dimming control. In this paper, we investigate the effect of the surface morphology of ITO on the resistance and dimmability of the panels. We have demonstrated that the peak-to-valley roughness of ITO should be much less than 20 nm or the resistance of the panels should be much higher than 1 MΩ in order to avoid an unwanted short-circuit phenomenon and thus achieve the high-yield fabrication of OLED lighting panels. It is also addressed that much care is taken to ensure a dimming control of OLED lighting panels with a larger active area because the resistance of those panels varies depending more sensitively on the surface roughness of ITO. (paper)

  5. Fabrication and laboratory-based performance testing of a building-integrated photovoltaic-thermal roofing panel

    International Nuclear Information System (INIS)

    Chen, Fangliang; Yin, Huiming

    2016-01-01

    Highlights: • A BIPVT solar panel is designed and fabricated for energy efficient buildings. • A high-speed manufacture method is developed to produce the functionally graded materials. • Laboratory tests demonstrate BIPVT’s energy efficiency improvement and innovations. • The PV efficiency is enhanced ∼24% through temperature control of the panel by water flow. • The combined electric and thermal efficiency reaches >75% of solar irradiation. - Abstract: A building integrated photovoltaic-thermal (BIPVT) multifunctional roofing panel has been developed in this study to harvest solar energy in the form of PV electricity as well as heat energy through the collection of warm water. As a key component of the multifunctional building envelope, an aluminum/high-density polyethylene (HDPE) functionally graded material (FGM) panel embedded with aluminum water tubes has been fabricated through the vibration-sedimentation approach. The FGM layer gradually transits material phases from well-conductive side (with aluminum dominated) to another highly insulated side (with HDPE). The heat in the PV cells can be easily transferred into the conductive side of the FGM and then collected by the water flow in the embedded tubes. Therefore, the operational temperature of the PV cells can be significantly lowered down, which recovers the PV efficiency in hot weather. In this way, the developed BIPVT panel is able to efficiently harvest solar energy in the form of both PV electricity and heat. The performance of a prototype BIPVT panel has been evaluated in terms of its thermal efficiency via warm water collection and PV efficiency via the output electricity. The laboratory test results demonstrate that significant energy conversion efficiency improvement can be achieved for both electricity generation and heat collection by the presented BIPVT roofing system. Overall, the performance indicates a very promising prospective of the new BIPVT multifunctional roofing panel.

  6. Consolidation of HIP bonding technologies for the ITER first wall panels

    International Nuclear Information System (INIS)

    Sherlock, P.; Peacock, A.; Roedig, M.

    2006-01-01

    Over the last decade alternative technologies for the manufacture of the ITER first wall have been progressively developed. Now, as the build of ITER approaches, the manufacturing route is being consolidated around the best solutions found to date. The design of the first wall is based on the concept of blanket modules, each faced by separable first wall panels. For the manufacture of the first wall panels two HIP bonding technologies are proposed by AMEC NNC; the first to bond together the composite copper alloy / stainless steel heat sink base, the second to bond the beryllium tiles to the copper alloy surface of the heat sink base. These technologies have been developed incrementally through the use of experiments, part scale mock-ups and full scale first wall panel prototypes. This paper reviews the development of the HIP bonding technologies identified above and discusses the latest results from components produced by AMEC NNC under the auspices of EFDA. The manufacturing stages, non-destructive examination and heat flux test results from the work are presented for the latest first wall mock-up components. Conclusions are then drawn with regard to the important aspects for the series production of components for ITER. (author)

  7. Multi-sensor control for precise assembly of optical components

    Directory of Open Access Journals (Sweden)

    Ma Li

    2014-06-01

    Full Text Available In order to perform an optical assembly accurately, a multi-sensor control strategy is developed which includes an attitude measurement system, a vision system, a loss measurement system and a force sensor. A 3-DOF attitude measuring method using linear variable differential transformers (LVDT is designed to adjust the relation of position and attitude between the spherical mirror and the resonator. A micro vision feedback system is set up to extract the light beam and the diaphragm, which can achieve the coarse positioning of the spherical mirror in the optical assembly process. A rapid self-correlation method is presented to analyze the spectrum signal for the fine positioning. In order to prevent the damage of the optical components and realize sealing of the resonator, a hybrid force-position control is constructed to control the contact force of the optical components. The experimental results show that the proposed multi-sensor control strategy succeeds in accomplishing the precise assembly of the optical components, which consists of parallel adjustment, macro coarse adjustment, macro approach, micro fine adjustment, micro approach and optical contact. Therefore, the results validate the multi-sensor control strategy.

  8. Expert Opinion Is Necessary: Delphi Panel Methodology Facilitates a Scientific Approach to Consensus.

    Science.gov (United States)

    Hohmann, Erik; Brand, Jefferson C; Rossi, Michael J; Lubowitz, James H

    2018-02-01

    Our current trend and focus on evidence-based medicine is biased in favor of randomized controlled trials, which are ranked highest in the hierarchy of evidence while devaluing expert opinion, which is ranked lowest in the hierarchy. However, randomized controlled trials have weaknesses as well as strengths, and no research method is flawless. Moreover, stringent application of scientific research techniques, such as the Delphi Panel methodology, allows survey of experts in a high quality and scientific manner. Level V evidence (expert opinion) remains a necessary component in the armamentarium used to determine the answer to a clinical question. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  9. The effect of oblique angle of sound incidence, realistic edge conditions, curvature and in-plane panel stresses on the noise reduction characteristics of general aviation type panels

    Science.gov (United States)

    Grosveld, F.; Lameris, J.; Dunn, D.

    1979-01-01

    Experiments and a theoretical analysis were conducted to predict the noise reduction of inclined and curved panels. These predictions are compared to the experimental results with reasonable agreement between theory and experiment for panels under an oblique angle of sound incidence. Theoretical as well as experimental results indicate a big increase in noise reduction when a flat test panel is curved. Further curving the panel slightly decreases the noise reduction. Riveted flat panels are shown to give a higher noise reduction in the stiffness-controlled frequency region, while bonded panels are superior in this region when the test panel is curved. Experimentally measured noise reduction characteristics of flat aluminum panels with uniaxial in-plane stresses are presented and discussed. These test results indicate an important improvement in the noise reduction of these panels in the frequency range below the fundamental panel/cavity frequency.

  10. Application of fuzzy synthetic assessment to assess human factors design level on reactor control panel

    International Nuclear Information System (INIS)

    Peng Xuecheng

    1999-01-01

    Reactor control panel design level on human factors must be considered by designer. The author evaluated the human factor design level of arrangement and combinations including the switch buttons, meter dials and indication lamps on Minjiang Reactor and High-Flux Engineer Test Reactor (HFETR) critical device by application of fuzzy synthetic assessment method in mathematics. From the assessment results, the advantages and shortcomings are fount, and some modification suggestions have also been proposed

  11. Panel and planar experimental shear behavior of wood panels ...

    African Journals Online (AJOL)

    Panel shear strength along the thickness and planar shear along the length of wood panels laminated softwood oriented OSB 10 mm thick, conditioned at different moisture contents (anhydrous medium, ambient temperature and humid medium) was measured on standardized test specimens, cut in half lengthwise panel ...

  12. Flight service evaluation of composite helicopter components

    Science.gov (United States)

    Mardoian, George H.; Ezzo, Maureen B.

    1994-01-01

    This paper presents the results of a NASA funded contract and Sikorsky research and development programs to evaluate structural composite components in flight service on Sikorsky Model S-76 helicopters. Selected components were removed and tested at prescribed intervals over a nine year time frame. Four horizontal stabilizers and thirteen tail rotor spars were returned from commercial service in West Palm Beach, Florida and in the Gulf Coast region of Louisiana to determine the long term effects of operations in hot and humid climates on component performance. Concurrent with the flight component evaluation, panels of materials used in their fabrication were exposed to the environment in ground racks. Selected panels were tested annually to determine the effects of exposure on physical and mechanical properties. The results of 55,741 component flight hours and 911 months of field exposure are reported and compared with initial Federal Aviation Administration (FAA) certification data. The findings of this program have provided increased confidence in the long term durability of advanced composite materials used in helicopter structural applications.

  13. Control panel for radiation around reactors (1963); Tableaux de controle des radiations aupres des piles (1963)

    Energy Technology Data Exchange (ETDEWEB)

    Candes, P; Barthoux, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-07-01

    This report outlines the general philosophy of radiation control in French reactors and their annexes. The supervision is carried out continuously from a central control panel on which appear all the measurements made and the alarm signals. The equipment is described; one item makes it possible to measure simultaneously the radioactive dusts and gases. The specifications of the alarm system, which is considered to be the most important are given. Finally a new measuring technique is proposed which makes it possible to reduce considerably the cost of radiation control while at the same time providing the results in a form in which they can be easily treated, in particular in the case of the calculation of total doses. (authors) [French] Ce rapport definit la philosophie generale du controle des radiations dans les piles francaises et dans leurs annexes. La surveillance se fait d'une maniere continue a partir d'un tableau de controle centralise ou sont reportees toutes les mesures et les signalisations d'alarme. On decrit les appareils utilises, dont un permet la mesure simultanee des poussieres et gaz radioactifs, et on definit les specifications de la fonction alarme qui est consideree comme la plus importante. Enfin on propose une nouvelle technique de mesure qui permettrait de reduire considerablement le cout du controle des radiations tout en fournissant des resultats plus facilement exploitables, en particulier pour le calcul des doses integrees. (auteurs)

  14. Flight service evaluation of Kevlar-49/epoxy composite panels in wide-bodied commercial transport aircraft

    Science.gov (United States)

    Stone, R. H.

    1977-01-01

    Kevlar-49 fairing panels, installed as flight service components on three L-1011s, were inspected after three years' service, and found to be performing satisfactorily. There are six Kevlar-49 panels on each aircraft, including sandwich and solid laminate wing-body panels, and 150 C service aft engine fairings. The service history to date indicates that Kevlar-49 epoxy composite materials have satisfactory service characteristics for use in aircraft secondary structure.

  15. Optimum design of composite panel with photovoltaic-thermo module. Absorbing effect of cooling panel; Hikari netsu fukugo panel no saiteki sekkei. Reikyaku panel no kyunetsu koka

    Energy Technology Data Exchange (ETDEWEB)

    Sato, M; Kikuchi, S; Tani, T [Science University of Tokyo, Tokyo (Japan); Kadotani, K; Imaizumi, H [Komatsu Ltd., Tokyo (Japan)

    1996-10-27

    The composite panel with photovoltaic-thermo module becomes higher in energy-saving than the conventional air-conditioning system by the independent radiational heating and cooling effect obtained when the generating panel using a solar cell module is combined with the heating and cooling panel using a thermo-element module. The output of a solar cell module can be directly used because the solar cell module operates in AC. This paper reports the relation between the absorbed value and power consumption of the cooling panel, while paying attention to the cooling panel. The performance coefficient of the maximum absorbed value from an non-absorbing substance to a cooling panel is 2 to 3. Assume that the cooling panel during non-adiabatic operation is operated using a solar cell module of 800 W/m{sup 2} in solar intensity and 15% in conversion efficiency. The cooling-surface temperature difference is 12.12 K, and the maximum absorbed value of a non-absorbing substance to a cooling panel is 39.12 W/m{sup 2}. The absorbed value of the outer temperature to the cooling panel is 74.4 W/m{sup 2}, and each performance coefficient is 3.26 and 0.62. The absorbed value must be calculated for evaluation from the cooling-surface temperature difference measured directly from the cooling panel. 4 refs., 8 figs., 1 tab.

  16. Control source development for reduction of noise transmitted through a double panel structure

    NARCIS (Netherlands)

    Ho, J.

    2014-01-01

    A double panel structure, which consists of two panels with air in between, is widely adopted in many applications such as aerospace, automotive industries, and buildings due to its low sound transmission at high frequencies, low heat transmission, and low weight. Nevertheless, the resonance of the

  17. Component configuration control system development at EBR-II

    International Nuclear Information System (INIS)

    Monson, L.R.; Stratton, R.C.

    1984-01-01

    One ofthe major programs being pursued by the EBR-II Division of Argonne National Laboratory is to improve the reliability of plant control and protection systems. This effort involves looking closely at the present state of the art and needs associated with plant diagnostic, control and protection systems. One of the areas of development at EBR-II involves a component configuration control system (CCCS). This system is a computerized control and planning aid for the nuclear power operator

  18. Web/smart phone based control and feedback systems for irrigation systems

    Science.gov (United States)

    The role of the internet and mobile devices in the control and feedback of irrigation systems is reviewed. This role is placed in the larger context of four distinct components required for irrigation management, including 1. the control panel; 2. remote control; 3. soil, plant, and weather (SPW) se...

  19. Designing for human performance - CANDU electrical panels - then and now

    International Nuclear Information System (INIS)

    Patterson, B.K.

    2003-01-01

    Experience has shown that few changes are made to CANDU control center panels once plants are in service. There are several reasons for this, for example, operational conservatism, outage minimization, avoidance of retraining effort, and perhaps lack of appreciation of improvement opportunities. Since the initial CANDU 6 plants were designed, the industry has moved forward with adoption of new approaches to control room interface design that have introduced changes in design principles and emphasis. At Point Lepreau, the electrical panels have remained virtually unchanged since initial design. The author, the original electrical system commissioning engineer, reviews the design considerations that led to the initial panel design, reviews some of the operational limitations discovered during use, and offers some suggestions on improvement directions, if these panels were being designed today, that would offer an implementation to better support operator tasks. (author)

  20. Detecting photovoltaic solar panels using hyperspectral imagery and estimating solar power production

    Science.gov (United States)

    Czirjak, Daniel

    2017-04-01

    Remote sensing platforms have consistently demonstrated the ability to detect, and in some cases identify, specific targets of interest, and photovoltaic solar panels are shown to have a unique spectral signature that is consistent across multiple manufacturers and construction methods. Solar panels are proven to be detectable in hyperspectral imagery using common statistical target detection methods such as the adaptive cosine estimator, and false alarms can be mitigated through the use of a spectral verification process that eliminates pixels that do not have the key spectral features of photovoltaic solar panel reflectance spectrum. The normalized solar panel index is described and is a key component in the false-alarm mitigation process. After spectral verification, these solar panel arrays are confirmed on openly available literal imagery and can be measured using numerous open-source algorithms and tools. The measurements allow for the assessment of overall solar power generation capacity using an equation that accounts for solar insolation, the area of solar panels, and the efficiency of the solar panels conversion of solar energy to power. Using a known location with readily available information, the methods outlined in this paper estimate the power generation capabilities within 6% of the rated power.

  1. Development and implementation of the quality control panel of RT-PCR and real-time RT-PCR for avian influenza A (H5N1 surveillance network in mainland China

    Directory of Open Access Journals (Sweden)

    Wang Wei

    2011-03-01

    Full Text Available Abstract Background Reverse transcription PCR (RT-PCR and real time RT-PCR (rRT-PCR have been indispensable methods for influenza surveillance, especially for determination of avian influenza. The movement of testing beyond reference lab introduced the need of quality control, including the implementation of an evaluation system for validating personal training and sample proficiency testing. Methods We developed a panel with lysates of seasonal influenza virus (H1N1, H3N2 and B, serials of diluted H5N1 virus lysates, and in-vitro transcribed H5 hemaglutinin (HA and an artificial gene RNAs for RT-PCR and rRT-PCR quality control assessment. The validations of stability and reproducibility were performed on the panel. Additionally, the panel was implemented to assess the detection capability of Chinese human avian influenza networks. Results The panel has relatively high stability and good reproducibility demonstrated by kappa's tests. In the implementation of panel on Chinese human avian influenza networks, the results suggested that there were a relatively low number of discrepancies for both concise and reproducibility in Chinese avian influenza virus net works. Conclusions A quality control panel of RT-PCR and real-time RT-PCR for avian influenza A (H5N1 surveillance network was developed. An availably statistical data, which are used to assess the detection capability of networks on avian influenza virus (H5N1, can be obtained relatively easily through implementation of the panel on networks.

  2. Space Shuttle Orbiter Wing-Leading-Edge Panel Thermo-Mechanical Analysis for Entry Conditions

    Science.gov (United States)

    Knight, Norman F., Jr.; Song, Kyongchan; Raju, Ivatury S.

    2010-01-01

    Linear elastic, thermo-mechanical stress analyses of the Space Shuttle Orbiter wing-leading-edge panels is presented for entry heating conditions. The wing-leading-edge panels are made from reinforced carbon-carbon and serve as a part of the overall thermal protection system. Three-dimensional finite element models are described for three configurations: integrated configuration, an independent single-panel configuration, and a local lower-apex joggle segment. Entry temperature conditions are imposed and the through-the-thickness response is examined. From the integrated model, it was concluded that individual panels can be analyzed independently since minimal interaction between adjacent components occurred. From the independent single-panel model, it was concluded that increased through-the-thickness stress levels developed all along the chord of a panel s slip-side joggle region, and hence isolated local joggle sections will exhibit the same trend. From the local joggle models, it was concluded that two-dimensional plane-strain models can be used to study the influence of subsurface defects along the slip-side joggle region of these panels.

  3. Suppression of panel flutter of near-space aircraft based on non-probabilistic reliability theory

    Directory of Open Access Journals (Sweden)

    Ye-Wei Zhang

    2016-03-01

    Full Text Available The vibration active control of the composite panels with the uncertain parameters in the hypersonic flow is studied using the non-probabilistic reliability theory. Using the piezoelectric patches as active control actuators, dynamic equations of panel are established by finite element method and Hamilton’s principle. And the control model of panel with uncertain parameters is obtained. According to the non-probabilistic reliability index, and besides being based on H∞ robust control theory and non-probabilistic reliability theory, the non-probabilistic reliability performance function is given. Moreover, the relationships between the robust controller and H∞ performance index and reliability are established. Numerical results show that the control method under the influence of reliability, H∞ performance index, and approaching velocity is effective to the vibration suppression of panel in the whole interval of uncertain parameters.

  4. 21 CFR 11.200 - Electronic signature components and controls.

    Science.gov (United States)

    2010-04-01

    ... signature components and controls. (a) Electronic signatures that are not based upon biometrics shall: (1) Employ at least two distinct identification components such as an identification code and password. (i... signatures based upon biometrics shall be designed to ensure that they cannot be used by anyone other than...

  5. Photovoltaic solar panels of crystalline silicon: Characterization and separation.

    Science.gov (United States)

    Dias, Pablo Ribeiro; Benevit, Mariana Gonçalves; Veit, Hugo Marcelo

    2016-03-01

    Photovoltaic panels have a limited lifespan and estimates show large amounts of solar modules will be discarded as electronic waste in a near future. In order to retrieve important raw materials, reduce production costs and environmental impacts, recycling such devices is important. Initially, this article investigates which silicon photovoltaic module's components are recyclable through their characterization using X-ray fluorescence, X-ray diffraction, energy dispersion spectroscopy and atomic absorption spectroscopy. Next, different separation methods are tested to favour further recycling processes. The glass was identified as soda-lime glass, the metallic filaments were identified as tin-lead coated copper, the panel cells were made of silicon and had silver filaments attached to it and the modules' frames were identified as aluminium, all of which are recyclable. Moreover, three different components segregation methods have been studied. Mechanical milling followed by sieving was able to separate silver from copper while chemical separation using sulphuric acid was able to detach the semiconductor material. A thermo gravimetric analysis was performed to evaluate the use of a pyrolysis step prior to the component's removal. The analysis showed all polymeric fractions present degrade at 500 °C. © The Author(s) 2016.

  6. Expanding to teleoperation of a tight modular workshop for dismantling radioactive components

    International Nuclear Information System (INIS)

    Gasc, B.

    1990-01-01

    The CEA (French Nuclear Energy Commission) in connection with TECHNICATOME developed a tight modular workshop for the dismantling of AT1 plant facilities in LA HAGUE. This workshop constructed of reusable stainless steel panels assembled by bolting provides a tight and decontaminable working zone compatible with any building configuration. This being the case, the operators bearing ventilated suits may work under the best safety conditions on alpha-contaminated materials. For the purpose of expanding the working capacities of this workshop it was decided to develop special components for teleoperation from the outside as in a conventional cell. To meet this objective which is within the scope of the contract signed with the CEC, the following components were developed and constructed: - manipulator holder panel, - swivelling hatch panel, - wall equipment sealed transfer device and, - modular biological protection. The design, construction and tests of these new components led to their qualification and further incorporation in the list of components of the modular workshop liable to be used for teleoperation procedures

  7. Persistence Heterogeneity Testing in Panels with Interactive Fixed Effects

    DEFF Research Database (Denmark)

    Ergemen, Yunus Emre; Velasco, Carlos

    We consider large N,T panel data models with fixed effects, a common factor allowing for cross-section dependence, and persistent data and shocks, which are assumed fractionally integrated. In a basic setup, the main interest is on the fractional parameter of the idiosyncratic component, which...

  8. Evaluation Logic of Main Control Board Fire Risk

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Dae Il; Kim, Kilyoo; Lim, Ho Gon [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    The main control board (MCB) is defined as the collection of control panels inside the main control room (MCR) of a nuclear power plant (NPP). As the MCB has the control and instrumentation circuits of redundant trains for almost all plant systems, small fires within the control panels may be detrimental to the safe shutdown capability. A big fire affecting many panels in the MCB can cause a forced MCR abandonment of the operators as well as function failures or spurious operations of the control and instrumentation-related components. If the MCR cannot be habitable, a safe shutdown from outside the MCR can be achieved and maintained at an alternate shutdown panel electrically and physically independent from the MCR. Because the MCB consist of many electrical panels, it may have internal barriers between them to prevent a fire from spreading from its origin to neighboring locations. However, most MCBs of domestic NPPs do not have internal barriers within them. If the MCB cabinets are not separated by a double wall with an air gap, the fire propagation of an MCB panel fire cannot be ruled out. Recently, Joglar et al. proposed a new evaluation logic for the MCB panel fires and mentioned that an MCB fire can be divided into propagation and non-propagating fires for abandonment and non-abandonment fire scenarios. However, they did not present the details on the fire modeling approaches and probability formulas for the fire scenarios. In this paper, a decision tree for evaluating the risk of an MCB fire is proposed to systematically determine the fire scenarios in terms of the fire modeling approaches. This paper proposed a decision tree for evaluating the risk of an MCB fire to systematically determine the fire scenarios in terms of fire modeling approaches.

  9. Radiant heating tests of several liquid metal heat-pipe sandwich panels

    International Nuclear Information System (INIS)

    Camarda, C.J.; Basiulis, A.

    1983-08-01

    Integral heat pipe sandwich panels, which synergistically combine the thermal efficiency of heat pipes and the structural efficiency of honeycomb sandwich construction, were conceived as a means of alleviating thermal stress problems in the Langley Scramjet Engine. Test panels which utilized two different wickable honeycomb cores, facesheets with screen mesh sintered to the internal surfaces, and a liquid metal working fluid (either sodium or potassium) were tested by radiant heating at various heat load levels. The heat pipe panels reduced maximum temperature differences by 31 percent with sodium working fluid and 45 percent with potassium working fluid. Results indicate that a heat pipe sandwich panel is a potential, simple solution to the engine thermal stress problem. Other interesting applications of the concept include: cold plates for electronic component and circuit card cooling, radiators for large space platforms, low distortion large area structures (e.g., space antennas) and laser mirrors

  10. A photodiode based on PbS nanocrystallites for FYTRONIX solar panel automatic tracking controller

    Science.gov (United States)

    Wageh, S.; Farooq, W. A.; Tataroğlu, A.; Dere, A.; Al-Sehemi, Abdullah G.; Al-Ghamdi, Ahmed A.; Yakuphanoglu, F.

    2017-12-01

    The structural, optical and photoelectrical properties of the fabricated Al/PbS/p-Si/Al photodiode based on PbS nanocrystallites were investigated. The PbS nanocrystallites were characterized by X-ray diffraction (XRD), UV-VIS-NIR, Infrared and Raman spectroscopy. The XRD diffraction peaks show that the prepared PbS nanostructure is in high crystalline state. Various electrical parameters of the prepared photodiode were analyzed from the electrical characteristics based on I-V and C-V-G. The photodiode has a high rectification ratio of 5.85×104 at dark and ±4 V. Moreover, The photocurrent results indicate a strong photovoltaic behavior. The frequency dependence of capacitance and conductance characteristics was attributed to depletion region behavior of the photodiode. The diode was used to control solar panel power automatic tracking controller in dual axis. The fabricated photodiode works as a photosensor to control Solar tracking systems.

  11. Effectiveness of a 95 SNP panel for the screening of breed label fraud in the Chinese meat market.

    Science.gov (United States)

    Rogberg-Muñoz, A; Wei, S; Ripoli, M V; Guo, B L; Carino, M H; Lirón, J P; Prando, A J; Vaca, R J A; Peral-García, P; Wei, Y M; Giovambattista, G

    2016-01-01

    Breed assignment has proved to be useful to control meat trade and protect the value of special productions. Meat-related frauds have been detected in China; therefore, 95 SNPs selected from the ISAG core panel were evaluated to develop an automated and technologically updated tool to screen breed label fraud in the Chinese meat market. A total of 271 animals from four Chinese yellow cattle (CYC) populations, six Bos taurus breeds, two Bos indicus and one composite were used. The allocation test distinguished European, Japanese and Zebu breeds, and two Chinese genetic components. It correctly allocated Japanese Black, Zebu and British breeds in 100, 90 and 89% of samples, respectively. CYC evidenced the Zebu, Holstein and Limousin introgression. The test did not detect CYC components in any of the 25 samples from Argentinean butchers. The method could be useful to certify Angus, Hereford and Japanese Black meat, but a modification in the panel would be needed to differentiate other breeds. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Flow induced vibration studies on PFBR control plug components

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, V., E-mail: prakash@igcar.gov.in [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu (India); Kumar, P. Anup; Anandaraj, M.; Thirumalai, M.; Anandbabu, C.; Rajan, K.K. [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu (India)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer Flow induced vibration studies on Prototype Fast Breeder Reactor control plug model carried out. Black-Right-Pointing-Pointer Velocity similitude was followed for the study. Black-Right-Pointing-Pointer Frequencies and amplitude of vibrations of various control plug components measured. Black-Right-Pointing-Pointer Overall values of vibration are well within permissible limits. - Abstract: The construction of Prototype Fast Breeder Reactor (PFBR), a 500 MWe liquid sodium cooled reactor, is in progress at Kalpakkam in India. Control plug (CP) is located right above the core subassemblies in the hot pool. Control plug is an important component as many of the critical reactor parameters are sensed and controlled by the components housed in the control plug assembly. In PFBR primary circuit, components are basically thin walled, slender shells with diameter to thickness ratio ranging from 100 to 650. These components are prone to flow induced vibrations. The existence of free liquid (sodium) surfaces, which is the source of sloshing phenomenon and the operation of primary sodium pump in the primary pool are other potential sources of vibration of reactor components. Control plug is a hollow cylindrical shell structure and provides passages and support for 12 absorber rod drive mechanisms (ARDM) which consists of 9 control and safety rods and 3 diverse safety rods, 210 thermo wells to measure the sodium temperature at the exit of various fuel subassemblies, three failed fuel localization modules (FFLM) and acoustic detectors. It consists of a core cover plate (CCP), which forms the bottom end, two intermediate supports plate, i.e. lower stay plate (LSP) and upper stay plate (USP) and an outer shell. The CCP is located at a distance of 1.3 m from the core top. With such a gap, there will be long free hanging length of the thermocouple sleeves, Delayed neutron detector (DND) sampling tubes and ARDM shroud tubes and hence they are

  13. Stressed skin panels

    Energy Technology Data Exchange (ETDEWEB)

    Anon

    2001-07-01

    Advantages and disadvantages of stressed skin panels, also known as structural insulated panels (SIPs), are discussed as material and labour-saving alternatives to traditional stick framing. Stressed skin panels are manufactured 'sandwich' assemblies with a rigid insulating polystyrene foam core, whose interior and exterior surfaces are bonded into panels. The skins distribute and carry the structural loading while the bonded foam core provides insulation and keeps the two skins aligned. Since there are fewer framing members, there is little thermal bridging and the R-value remains high. SIPs are usually manufactured in four feet by eight feet panels, although some manufacturers can produce panels up to eight feet by forty feet. SIPs are resource efficient as they use less wood than conventional framing (about 25 per cent less); can structurally cover large spans, requiring less supplementary framing. Use of SIPs eliminate the need for headers over small openings; provide the ability to nail anywhere; create less scrap and waste; lessen vulnerability to unfavourable weather and other job-site hazards, can reduce delays, and often can produce significant savings in material and labour costs. Limitations include the more complex approaches to plumbing and electrical systems, although this can be minimized by designers by incorporating much of the plumbing and electrical work on interior (non-panel) walls. Most stressed skin panels require one-half inch interior gypsum drywall. If become wet, stressed skin panels take a long time to dry out and may harbour mold growth. Larger stressed-skin panels used in floors and roofs, may require cranes or other machinery for handling because of their weight. Although not without some environmental impact, overall, stressed skin panels are judged to be a resource-efficient building technology with significant energy-efficiency benefits and distinct advantages over stick framing. 3 photos.

  14. Weight reductions for the airbus A380; postbuckling of the A380 VTP skin panels

    NARCIS (Netherlands)

    Kroese, R.

    2014-01-01

    The skin panels of the Vertical Tail Plane (VTP) are the largest single piece composite components assembled on the Airbus A380. By allowing postbuckling to these skin panels might result in severe weight reductions for the VTP of the A380. The goal of the study is to give an indication of possible

  15. Methods of Si based ceramic components volatilization control in a gas turbine engine

    Science.gov (United States)

    Garcia-Crespo, Andres Jose; Delvaux, John; Dion Ouellet, Noemie

    2016-09-06

    A method of controlling volatilization of silicon based components in a gas turbine engine includes measuring, estimating and/or predicting a variable related to operation of the gas turbine engine; correlating the variable to determine an amount of silicon to control volatilization of the silicon based components in the gas turbine engine; and injecting silicon into the gas turbine engine to control volatilization of the silicon based components. A gas turbine with a compressor, combustion system, turbine section and silicon injection system may be controlled by a controller that implements the control method.

  16. A NEW CONTROL CIRCUIT AND COMPUTER SOFTWARE FOR CONTROLING PHOTOVOLTAIC SYSTEMS

    Directory of Open Access Journals (Sweden)

    Mustafa Berkant SELEK

    2008-02-01

    Full Text Available In this study, a new microcontroller circuit was designed and new computer software was implemented to control power flow currents of renewable energy system, which is established in Solar Energy Institute, Ege University, Bornova, Izmir, Turkey. PIC18F452 microcontroller based electronic circuit was designed to control another electronic circuit that includes power electronic switching components. Readily available standard control circuits are designed for switching single level inverters. In contrary, implemented circuit allows to switch multilevel inverters. In addition, because the efficiency of solar energy panels is considerably low, solar panels should be operated under the maximum power point (MPP. Therefore, MPP algorithm is included in the designed control circuit. Next, the control circuit also includes a serial communication interface based on RS232 standard. Using this interface enables the user to choose all functions available in the control circuit and take status report via computer software. Last, a general purpose command set was designed to establish communication between the computer software and the microcontroller-based control circuit. As a result, it is aimed that this study supply a basis for the researchers who want to develop own control circuits or more visual software.

  17. Developing a Toolset Supporting the Construction of Reusable Components for Embedded Control Systems

    DEFF Research Database (Denmark)

    Guan, Wei; Sierszecki, Krzysztof; Angelov, Christo K.

    2010-01-01

    Reusing software components for embedded control applications enhances product quality and reduces time to market when appropriate (formal) methodologies and supporting toolsets are available. That is why industrial companies are interested in developing trusted, in-house reusable components for ...... on open-source technology, in accordance with industrial requirements, as well as the approach used to engineer a toolset supporting component development for embedded control applications.......Reusing software components for embedded control applications enhances product quality and reduces time to market when appropriate (formal) methodologies and supporting toolsets are available. That is why industrial companies are interested in developing trusted, in-house reusable components...

  18. A mobility based vibroacoustic energy transmission simulation into an enclosure through a double-wall panel.

    Science.gov (United States)

    Sahu, Atanu; Bhattacharya, Partha; Niyogi, Arup Guha; Rose, Michael

    2017-06-01

    Double-wall panels are known for their superior sound insulation properties over single wall panels as a sound barrier. The sound transmission phenomenon through a double-wall structure is a complex process involving vibroacoustic interaction between structural panels, the air-cushion in between, and the secondary acoustic domain. It is in this context a versatile and a fully coupled technique based on the finite-element-boundary element model is developed that enables estimation of sound transfer through a double-wall panel into an adjacent enclosure while satisfying the displacement compatibility across the interface. The contribution of individual components in the transmitted energy is identified through numerical simulations.

  19. Comprehensive metabolic panel

    Science.gov (United States)

    Metabolic panel - comprehensive; Chem-20; SMA20; Sequential multi-channel analysis with computer-20; SMAC20; Metabolic panel 20 ... Chernecky CC, Berger BJ. Comprehensive metabolic panel (CMP) - blood. In: ... Tests and Diagnostic Procedures . 6th ed. St Louis, MO: ...

  20. Unemployment, Investment and Global Expected Returns: A Panel FAVAR Approach

    OpenAIRE

    Ron Smith; Gylfi Zoega

    2005-01-01

    We consider the hypothesis that a common factor, global expected returns, drives unemployment and investment in 21 OECD countries over the period 1960-2002. We investigate this hypothesis using a panel-factor augmented-vector autoregression (FAVAR). We first estimate the common factors of unemployment and investment by principal components and show that the first principal component of unemployment is almost identical to that of investment and that they both show the pattern one would expect ...

  1. STRUCTURAL ANALYSIS OF WOOD-LEATHER PANELS BY RAMAN SPECTROSCOPY

    Directory of Open Access Journals (Sweden)

    Tilman Grünewald,

    2012-02-01

    Full Text Available Besides other ligno-cellulosic materials such as straw, rice husks, or bagasse, wet blue particles from leather production are a promising new raw material stock for wood-based panels, as they offer not only a high availability, but increase the properties of the panel with regard to fire resistance or mechanical characteristics. A panel with a mixture of 42.5% wood fibers, 42.5% wet blue leather particles, and 15% lignin adhesive was produced, and an inhomogeneous sample was prepared. An area of 9 x 10 mm was rasterized and scanned by means of Raman Spectroscopy. Furthermore, the reference spectra of the constituents, i.e. wood fiber, wet blue leather particle, and lignin powder were recorded. The obtained data were treated and analyzed using chemometric methods (principal components analysis PCA and cluster analysis. An important finding was that the reference data were not directly represented in the panels’ spectra, and the correlation matrix of the PCA was not applicable to the panel data. This indicated that chemical changes might take place during the pressing. After processing the panel Raman spectra with the help of PCA and cluster analysis, three distinctive clusters were obtained, discriminating wood, leather, and mixed regions. With the assigned spectral information, it was possible to create a spectral image of the surface.

  2. Increasing photovoltaic panel power through water cooling technique

    Directory of Open Access Journals (Sweden)

    Calebe Abrenhosa Matias

    2017-02-01

    Full Text Available This paper presents the development of a cooling apparatus using water in a commercial photovoltaic panel in order to analyze the increased efficiency through decreased operating temperature. The system enables the application of reuse water flow, at ambient temperature, on the front surface of PV panel and is composed of an inclined plane support, a perforated aluminum profile and a water gutter. A luminaire was specially developed to simulate the solar radiation over the module under test in a closed room, free from the influence of external climatic conditions, to carry out the repetition of the experiment in controlled situations. The panel was submitted to different rates of water flow. The best water flow rate was of 0.6 L/min and net energy of 77.41Wh. Gain of 22.69% compared to the panel without the cooling system.

  3. PERBANDINGAN UNJUK KERJA ANTARA PANEL SEL SURYA BERPENJEJAK DENGAN PANEL SEL SURYA DIAM

    Directory of Open Access Journals (Sweden)

    Syafaruddin Ch

    2010-07-01

    Full Text Available The ability to produce electrical energy at Solar Power Plant  is highly dependent on the magnitude and duration of sun exposure on the solar cell panels. The movement of the sun from east to west that periodicity in every day is a problem at  the  optimization generation of electricity at  Solar Power Plant   if using solar panel that motionless. This is because the solar cell panel can not catch the maximum sun exposure. To solve the above problem then designed a solar cell panel  tracker  capable of follo-wing the movements of the sun. Then conducted a test to see the performance of solar cell pa-nel  tracker  and compare it with the performance of solar cell panel was motionless. The testing doing along 6 days, with way to irradiate the panel of solar cells  tracker  and panels of solar cell motionless with sun exposure  along a  full day. Then the electric current generated each panel were recorded. The comparison of current then generating comparison of electric power delivery. The result show that the solar cell panel  tracker  produce the average current is 2.19 A whereas solar-cell panel still 1.97 A.  This result   indicate that average power for solar cell panel  tracker  39.41 W while for solar cell panel that motionless is  35.46 W. These results indicate that the performance of solar cell panel  tracker  better than  solar cell panel motionless.

  4. Optimized Synthesis of Foam Glass from Recycled CRT Panel Glass

    DEFF Research Database (Denmark)

    Petersen, Rasmus Rosenlund; König, Jakob; Yue, Yuanzheng

    Most of the panel glass from cathode ray tubes (CRTs) is landfilled today. Instead of landfilling, the panel glass can be turned into new environment-friendly foam glass. Low density foam glass is an effective heat insulating material and can be produced just by using recycle glass and foaming...... additives. In this work we recycle the CRT panel glass to synthesize the foam glass as a crucial component of building and insulating materials. The synthesis conditions such as foaming temperature, duration, glass particle size, type and concentrations of foaming agents, and so on are optimized...... by performing systematic experiments. In particular, the concentration of foaming agents is an important parameter that influences the size of bubbles and the distribution of bubbles throughout the sample. The foam glasses are characterised regarding density and open/closed porosity. Differential scanning...

  5. Monitoring and control of a hybrid energy system

    International Nuclear Information System (INIS)

    Raceanu, M.; Culcer, M.; Patularu, L.; Enache, A.; Balan, M.; Varlam, M.

    2010-01-01

    Full text: This article presents monitoring and control of a Hybrid Energy System (HES). The HES is composed of six main components: solar panels, electrolyzer, fuel cells stack, charge controller, DC-AC inverter and lead acid batteries. Solar panels function as the primary source of energy, converting the energy from the sun into electricity that is given to a DC bus. Electrolyzer is a device that produces hydrogen and oxygen from the water following a process electrochemical. When there is excess energy from solar panels, electrolyzer is switched to produce hydrogen which is stored in hydrogen tank. Hydrogen produced is used by an assembly of fuel cell; this produces electricity that is transmitted on the DC bus, using hydrogen produced by electrolysis. Can be measured and displayed in real time data including, voltage, current, flow of hydrogen from the fuel cell, voltage, current, temperature of the photovoltaic panels, pressure hydrogen from electrolysis, pressure hydrogen tank and battery voltage. The control system is designed according to state of charge (SoC) of the battery. Are presented control strategy which ensures the On/Off control of the electrolyzer, to consume electricity from the battery and to generate electricity from fuel cells. The system hardware consists of an acquisition board, communication system of type CAN, sensors and interface devices. Monitoring and control software was developed in LabView 9.0. (authors)

  6. Thermal conductivity of newspaper sandwiched aerated lightweight concrete panel

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Soon-Ching; Low, Kaw-Sai [Faculty of Engineering and Science, Universiti Tunku Abdul Rahman, Jalan Genting Kelang, Setapak, 53300 Kuala Lumpur, Wilayah Persekutuan (Malaysia)

    2010-12-15

    Investigation on the thermal conductivity of newspaper sandwiched aerated lightweight concrete (ALC) panels is the main purpose of this study. Various densities of ALC panels ranging from 1700, 1400 and 1100 kg/m{sup 3} with three different aerial intensities of newspaper sandwiched were produced. Investigation was limited to the effect of aerial intensity of newspaper sandwiched and the effect of density of ALC on thermal conductivity. It is found that the thermal conductivity of newspaper sandwiched ALC panels reduced remarkably compared to control ALC panels. The reduction was recorded at 18.0%, 21.8% and 20.7% correspond to densities of 1700, 1400 and 1100 kg/m{sup 3} with just a mere 0.05 g/cm{sup 2} aerial intensity of newspaper sandwiched. Newspaper sandwiched has a significant impact on the performance of thermal conductivity of ALC panels based on regression analysis. (author)

  7. A comprehensive custom panel design for routine hereditary cancer testing: preserving control, improving diagnostics and revealing a complex variation landscape.

    Science.gov (United States)

    Castellanos, Elisabeth; Gel, Bernat; Rosas, Inma; Tornero, Eva; Santín, Sheila; Pluvinet, Raquel; Velasco, Juan; Sumoy, Lauro; Del Valle, Jesús; Perucho, Manuel; Blanco, Ignacio; Navarro, Matilde; Brunet, Joan; Pineda, Marta; Feliubadaló, Lidia; Capellá, Gabi; Lázaro, Conxi; Serra, Eduard

    2017-01-04

    We wanted to implement an NGS strategy to globally analyze hereditary cancer with diagnostic quality while retaining the same degree of understanding and control we had in pre-NGS strategies. To do this, we developed the I2HCP panel, a custom bait library covering 122 hereditary cancer genes. We improved bait design, tested different NGS platforms and created a clinically driven custom data analysis pipeline. The I2HCP panel was developed using a training set of hereditary colorectal cancer, hereditary breast and ovarian cancer and neurofibromatosis patients and reached an accuracy, analytical sensitivity and specificity greater than 99%, which was maintained in a validation set. I2HCP changed our diagnostic approach, involving clinicians and a genetic diagnostics team from panel design to reporting. The new strategy improved diagnostic sensitivity, solved uncertain clinical diagnoses and identified mutations in new genes. We assessed the genetic variation in the complete set of hereditary cancer genes, revealing a complex variation landscape that coexists with the disease-causing mutation. We developed, validated and implemented a custom NGS-based strategy for hereditary cancer diagnostics that improved our previous workflows. Additionally, the existence of a rich genetic variation in hereditary cancer genes favors the use of this panel to investigate their role in cancer risk.

  8. Study of the cracking of sandwich panels of plasterboard and rockwool

    Directory of Open Access Journals (Sweden)

    Alonso, J. A.

    2013-09-01

    Full Text Available This paper presents the study of plasterboard and rockwool sandwich panels cracking under flexural loading. These panels are usually used to perform interior partition walls and they frequently show cracking pathology due to excessive deflexion of the slabs. There are currently no reliable simulation models and experimental data for the study of this problem. This paper presents the results of an experimental campaign aimed to characterize the fracture behaviour of sandwich panels and their individual components. In addition, the paper presents a cohesive model with embedded crack to simulate the fracture behaviour of the panel. Finally we present the results of tests for mixed mode fracture (tensile / shear commercial panels and their behaviour is reproduced with the cohesive model proposed, yielding a good fit.Este artículo presenta el estudio de la rotura de paneles sándwich de yeso laminado y lana de roca bajo solicitaciones de flexo-tracción dentro de su plano. Estos paneles se emplean para conformar tabiques interiores de edificación y con frecuencia se fisuran por flechas excesivas en los forjados. Actualmente no hay modelos de cálculo fiables ni datos experimentales que permitan estudiar este problema. Este trabajo presenta los resultados de una campaña experimental encaminada a caracterizar el comportamiento en rotura de los paneles sándwich y de sus componentes individuales. Además, se presenta un modelo cohesivo con fisura embebida que permite simular el comportamiento en rotura del panel sándwich conjunto. Por último se presentan los resultados de los ensayos de fractura en modo mixto (tracción/cortante de paneles comerciales y se reproduce su comportamiento con el modelo cohesivo propuesto, obteniéndose un buen ajuste.

  9. Novel Human Radiation Exposure Biomarker Panel Applicable for Population Triage

    Energy Technology Data Exchange (ETDEWEB)

    Bazan, Jose G. [Department of Radiation Oncology, Stanford University, Stanford, California (United States); Chang, Polly; Balog, Robert; D' Andrea, Annalisa; Shaler, Thomas; Lin, Hua; Lee, Shirley; Harrison, Travis [SRI International, Menlo Park, California (United States); Shura, Lei; Schoen, Lucy; Knox, Susan J. [Department of Radiation Oncology, Stanford University, Stanford, California (United States); Cooper, David E., E-mail: david.cooper@sri.com [SRI International, Menlo Park, California (United States)

    2014-11-01

    Purpose: To identify a panel of radiation-responsive plasma proteins that could be used in a point-of-care biologic dosimeter to detect clinically significant levels of ionizing radiation exposure. Methods and Materials: Patients undergoing preparation for hematopoietic cell transplantation using radiation therapy (RT) with either total lymphoid irradiation or fractionated total body irradiation were eligible. Plasma was examined from patients with potentially confounding conditions and from normal individuals. Each plasma sample was analyzed for a panel of 17 proteins before RT was begun and at several time points after RT exposure. Paired and unpaired t tests between the dose and control groups were performed. Conditional inference trees were constructed based on panels of proteins to compare the non-RT group with the RT group. Results: A total of 151 patients (62 RT, 41 infection, 48 trauma) were enrolled on the study, and the plasma from an additional 24 healthy control individuals was analyzed. In comparison with to control individuals, tenascin-C was upregulated and clusterin was downregulated in patients receiving RT. Salivary amylase was strongly radiation responsive, with upregulation in total body irradiation patients and slight downregulation in total lymphoid irradiation patients compared with control individuals. A panel consisting of these 3 proteins accurately distinguished between irradiated patients and healthy control individuals within 3 days after exposure: 97% accuracy, 0.5% false negative rate, 2% false positive rate. The accuracy was diminished when patients with trauma, infection, or both were included (accuracy, 74%-84%; false positive rate, 14%-33%, false negative rate: 8%-40%). Conclusions: A panel of 3 proteins accurately distinguishes unirradiated healthy donors from those exposed to RT (0.8-9.6 Gy) within 3 days of exposure. These findings have significant implications in terms of triaging individuals in the case of nuclear or other

  10. Differential conductivity mapping of solar panels using a high-TC superconductor SQUID

    International Nuclear Information System (INIS)

    Kiwa, T.; Maeda, S.; Miyake, K.; Kataoka, N.; Tsukamoto, A.; Adachi, S.; Tanabe, K.; Kandori, A.; Tsukada, K.

    2011-01-01

    To visualise the distribution of the electric property of solar cells, we developed a differential conductivity mapping system using high-T C (HTS-) superconductor SQUID with a normal conducting pick-up coil. The bias ac voltage with an offset voltage was applied to a solar panel made from amorphous silicon, and the normal component of the generated magnetic field was lock-in-detected. Thus the measured signal was converted to dB/dV properties, which are inverse-proportional to the differential resistivity, as the function of the offset voltage. By scanning the pick-up coil across the panel surface, we obtained the distribution of dB/dV properties across the solar panel was obtained by scanning the pick-up coil across the panel surface. The distribution of dB/dV on the panel differed between when the light source was on and when it was off. This result suggests that the proposed system is a potential tool for diagnosing the electric properties of solar cells.

  11. Propiedades acústicas de los paneles de carrizo

    Directory of Open Access Journals (Sweden)

    Díaz, César

    2012-03-01

    Full Text Available Reed is a plant species very similar to common cane which is widespread all over the Earth. It is an ecological and sustainable material which is low-cost, aesthetically attractive, easy to obtain and install, and can be used in different construction systems. This work analyses the acoustic properties of reed panels from the point of view of sound absorption and sound insulation against airborne noise, according to the corresponding EN ISO standards. The experimental results obtained point to the conclusion that reed panels are suitable construction systems for controlling reverberant sound within a space, and that the sound reduction index values for different thicknesses of reed panels, or reed panels used in combination with wood particle boards, demonstrate the possibility of using them in construction as an element on the facades and roofs of buildings and for interior partitions.

    El carrizo es una especie vegetal, parecida a la caña común, que se encuentra ampliamente distribuida en la superficie terrestre. Es un material ecológico y sostenible de bajo coste, estéticamente aceptable, fácil de obtener y colocar, que permite generar diferentes sistemas constructivos. En este trabajo se analizan las propiedades acústicas de los paneles de carrizo en lo referente a la absorción acústica y al aislamiento acústico a ruido aéreo, para ello se han aplicado los procedimientos de las normas EN ISO correspondientes. De los resultados experimentales obtenidos se concluye que los paneles de carrizo son unos sistemas constructivos adecuados para el control del sonido reverberante en un recinto y que los valores del índice de reducción acústica de paneles de diferentes espesores o en combinación con tableros de partículas de madera muestran la posibilidad de utilizarlos en la edificación como elemento de fachada, en cubiertas de edificios y particiones interiores.

  12. Evaluation of proposed panel closure modifications at WIPP

    Energy Technology Data Exchange (ETDEWEB)

    Allen, Lawrence E.; Silva, Matthew K.; Channell, James K.; Abel, John F.; Morgan, Dudley R.

    2001-12-31

    A key component in the design of the WIPP repository is the installation of concrete structures as panel seals in the intake and exhaust drifts after a panel has been filled with waste containers. As noted in the EPA final rule, the panel seal closure system is intended to block brine flow between the waste panels at the WIPP. On April 17, 2001, the DOE proposed seven modifications to the EPA concerning the design of the panel closure system. EPA approval of these modifications is necessary since the details of the panel design are specified in EPA’s final rule as a condition for WIPP certification. However, the EPA has not determined whether a rulemaking would be required for these proposed design modifications. On September 4, 2001, the DOE withdrew the request, noting that it would be resubmitted on a future date. The Environmental Evaluation Group (EEG) contracted with two engineers, Dr. John Abel and Dr. Rusty Morgan, to evaluate the proposed modifications. The EEG has accepted the conclusions and recommendations from these two experts: 1) replacement of Salado Mass Concrete with a generic salt-based concrete; 2) replacement of the explosion wall with a construction wall; 3) replacement of freshwater grouting with salt-based grouting; 4) option to allow surface or underground mixing; and 5) option to allow up to one year for completion of closure. The proposed modification to allow local carbonate river rock as aggregate is acceptable pending demonstration that no problems will exist in the resulting concrete. The proposed modification to give the contractor discretion in removal of steel forms is not supported. Instead, several recommendations are made to specifically reduce the number of forms left, thereby reducing potential migration pathways.

  13. Semimanufacture intended to be mounted on a vibrating wall or a vibrating panel for actively damping vibrations of the wall, wall or panel provided with such semimanufacture, system provided with a semimanufacture and a control unit, wall or panel provided with a control unit and method for damping audible vibrations of a wall or panel

    NARCIS (Netherlands)

    de Goeje, Marius; van Overbeek, Michiel Wilbert R.M.; van der Waal, Adri; Berkhoff, Arthur P.; Nederveen, Peter J.

    2005-01-01

    A semimanufacture intended to be mounted on a vibrating wall or a vibrating panel for actively damping the vibrations in the wall or the panel with frequencies which are at least partly audible, wherein the semimanufacture is provided with a plate wherein the plate is integrated with: at least one

  14. Panel 5: Microbiology and Immunology Panel

    Science.gov (United States)

    Murphy, Timothy F.; Chonmaitree, Tasnee; Barenkamp, Stephen; Kyd, Jennelle; Nokso-Koivisto, Johanna; Patel, Janak A.; Heikkinen, Terho; Yamanaka, Noboru; Ogra, Pearay; Swords, W. Edward; Sih, Tania; Pettigrew, Melinda M.

    2014-01-01

    Objective The objective is to perform a comprehensive review of the literature from January 2007 through June 2011 on the virology, bacteriology, and immunology related to otitis media. Data Sources PubMed database of the National Library of Medicine. Review Methods Three subpanels with co-chairs comprising experts in the virology, bacteriology, and immunology of otitis media were formed. Each of the panels reviewed the literature in their respective fields and wrote draft reviews. The reviews were shared with all panel members, and a second draft was created. The entire panel met at the 10th International Symposium on Recent Advances in Otitis Media in June 2011 and discussed the review and refined the content further. A final draft was created, circulated, and approved by the panel. Conclusion Excellent progress has been made in the past 4 years in advancing an understanding of the microbiology and immunology of otitis media. Advances include laboratory-based basic studies, cell-based assays, work in animal models, and clinical studies. Implications for Practice The advances of the past 4 years formed the basis of a series of short-term and long-term research goals in an effort to guide the field. Accomplishing these goals will provide opportunities for the development of novel interventions, including new ways to better treat and prevent otitis media. PMID:23536533

  15. A Panel Analysis Of UK Industrial Company Failure

    OpenAIRE

    Natalia Isachenkova; John Hunter

    2002-01-01

    We examine the failure determinants for large quoted UK industrials using a panel data set comprising 539 firms observed over the period 1988-93. The empirical design employs data from company accounts and is based on Chamberlain’s conditional binomial logit model, which allows for unobservable, firm-specific, time-invariant factors associated with failure risk. We find a noticeable degree of heterogeneity across the sample companies. Our panel results show that, after controll...

  16. Multi-component controllers in reactor physics optimality analysis

    International Nuclear Information System (INIS)

    Aldemir, T.

    1978-01-01

    An algorithm is developed for the optimality analysis of thermal reactor assemblies with multi-component control vectors. The neutronics of the system under consideration is assumed to be described by the two-group diffusion equations and constraints are imposed upon the state and control variables. It is shown that if the problem is such that the differential and algebraic equations describing the system can be cast into a linear form via a change of variables, the optimal control components are piecewise constant functions and the global optimal controller can be determined by investigating the properties of the influence functions. Two specific problems are solved utilizing this approach. A thermal reactor consisting of fuel, burnable poison and moderator is found to yield maximal power when the assembly consists of two poison zones and the power density is constant throughout the assembly. It is shown that certain variational relations have to be considered to maintain the activeness of the system equations as differential constraints. The problem of determining the maximum initial breeding ratio for a thermal reactor is solved by treating the fertile and fissile material absorption densities as controllers. The optimal core configurations are found to consist of three fuel zones for a bare assembly and two fuel zones for a reflected assembly. The optimum fissile material density is determined to be inversely proportional to the thermal flux

  17. The development of an Infrared Environmental System for TOPEX Solar Panel Testing

    Science.gov (United States)

    Noller, E.

    1994-01-01

    Environmental testing and flight qualification of the TOPEX/POSEIDON spacecraft solar panels were performed with infrared (IR) lamps and a control system that were newly designed and integrated. The basic goal was more rigorous testing of the costly panels' new composite-structure design without jeopardizing their safety. The technique greatly reduces the costs and high risks of testing flight solar panels.

  18. new developments for control room habitability evaluation and analysis. Panel Discussion

    International Nuclear Information System (INIS)

    Cozens, Kurt O.; Harvey, Robert B. Jr.; Hayes, John J. Jr.; Jarosz, Gregory; Lagus, Peter L.; Taplett, Kenneth J.; Schultz, Stephen P.

    2001-01-01

    In 2000, the Nuclear Energy Institute (NEI), nuclear utilities, and the U.S. Nuclear Regulatory Commission (NRC) embarked on a series of working meetings designed to develop means to assess the post-accident performance of control room ventilation systems to ensure required control room habitability (CRH). Through monthly meeting interactions beginning in January 2000, teams from the industry and the NRC have been working to develop an industry approach for assessment of existing systems. New system evaluation techniques are being developed that will allow for evaluation and/or identification of potential performance improvement options. NRC review of the documentation of this approach, as well as broad industry comment, was performed in the first part of 2001. This session will examine technical development topics covering licensing, analysis, testing, and control room refurbishment. NRC, NEI, utility, vendor, and consultant presentations will be followed by a panel session that will explore both process and technical recommendations for improvements. Since the mid-1980's, the NRC has communicated concerns on the inadequacies of control room designs relating to CRH requirements. In the mid-1990's, testing of some control room envelopes indicated that key assumptions supporting the radiological dose analysis might be incorrect. In 1998, the NRC held a public workshop to address CRH concerns. In late 1999, the NRC and the industry agreed to work together on issues affecting CRH and develop the NEI 99-03 guidance document for resolving those issues. This NEI 99-03 industry document defines a process for licensees to assess a plant's design and licensing bases for CRH to ensure that they are established and maintained throughout the life of the plant. The assessment process describes a comparative approach to determine if the plant configuration and operation are consistent with the CRH licensing basis and analysis. The process includes evaluation, testing, and

  19. NSSS Component Control System Design of Integral Reactor

    International Nuclear Information System (INIS)

    Lee, Joon Koo; Kwon, Ho Je; Jeong, Kwong Il; Park, Heui Youn; Koo, In Soo

    2005-01-01

    MMIS(Man Machine Interface System) of an integral reactor is composed of a Control Room, Plant Protection System, Control System and Monitoring System which are related with the overall plant operation. MMIS is being developed with a new design concept and digital technology to reduce the Human Factor Error and improve the systems' safety, reliability and availability. And CCS(component control system) is also being developed with a new design concept and digital hardware technology A fully digitalized system and design concept are introduced in the NSSS CCS

  20. Manufacture of New Set of Calorimeter Panels for the Neutral Beam Injection of ASDEX Upgrade

    International Nuclear Information System (INIS)

    Huber, T.; Zabernig, A.; Riedel, R.; Schedler, B.; Froeschle, M.; Heinemann, B.; Entcheva, A.; Weigert, J.

    2006-01-01

    The Neutral Injection of ASDEX-Upgrade employs calorimeter panels to measure the power of the neutral beam. These components are designed to safely absorb specific heat flux loads as high as 25 MW/m 2 over a period of 10 s. The currently used calorimeter panels have reached after ten years the end of their service life time and have to be replaced. The components consist of the CuCrZr which is a precipitation hardened alloy. The selection of the manufacturing process therefore determines the final thermal and mechanical properties of the alloy. In the past these components were manufactured by a two step brazing process, at about 830 o C and 730 o C, respectively. This led to an overaging of the material resulting in low mechanical properties. As predicted by finite element calculations the cyclic heat flux load leads to ratcheting at the heated surface finally limiting the life time of the components. In order to increase the service life time of the component it has therefore been decided to employ electron beam welding as the only joining technique to realise the required joints of the components. To fully characterise this manufacturing route a qualification programme has been performed, which ended in the manufacture of prototypes. These have been tested in ASEDEX Upgrade in comparison to brazed components. After successful qualification of design and processes the manufacture and testing of 100 calorimeter panels has been launched and completed recently. The used design, the results of the qualification tests, the manufacturing sequence and the applied non-destructive methods will be described in the paper. (author)

  1. Manufacturing of 380/220 V 63 A power supply panel on UO2 kernel coating unit

    International Nuclear Information System (INIS)

    Triyono; Mudjiman, Supardjono; Hidayat, Nur

    2013-01-01

    The panel 380/220 Volts voltage source current 63 Amperes relay AC output on UO 2 kernel coating unit has been manufactured. The activities include: installation and function panel test. The electrical installation of load includes : 220 Volts temperature monitor/controller, 220 Volts scraber pump, 220 Volts vacuum pump, 220 Volts solenoid valve gas and 380 Volts induction furnace. The component of installation includes: 380 Volts earth leakage circuit breaker, 380 Volts relay AC, 220 Volts magnetic circuit breaker, 100/5 Amperes current transformator ratio, voltmeter, ampermeter and push button normally open-close and temperature monitor/control in the box size 70x50x20 cm. The testing of voltage source has been unload and full load to determine the performance of the tool. The result of manufacture and function test voltage source 380/220 Volts at the UO 2 kernel coating unit showed that: the voltage source can work without load and full load safely. The load includes: voltage 380-382 Volts current 4-4,1 Amperes of induction furnace, voltage 223 Volts current 0,5 Amperes of vacuum pump, voltage 223 Volts current 4 Amperes of scraber pump, voltage 223 Volts current 0,3 Amperes of solenoid valve gas and 222 Volts current 0,03 Amperes temperature monitor/control. (author)

  2. Supply of a prototype component for the ITER divertor baffle

    International Nuclear Information System (INIS)

    Bobin-Vastra, I.; Febvre, M.; Schedler, B.; Ploechl, L.; Bouveret, Y.; Cauvin, D.; Raisson, G.; Merola, M.

    2001-01-01

    The ITER divertor baffle is one of the Plasma facing components which are developed in the frame of the ITER concept. The supply consisted in the manufacturing of four panels with four First Wall geometries using macroblock or heat sink+armour concepts. DS-Copper, and CuCrZr were the materials for the heat sink, and CFC or Tungsten Plasma spray were the armour. The panels included two Copper-based tubes each. The final purpose is the comparison of the fabricability of each type and the performances of each panel under heat fluxes

  3. Experimental and Numerical Research of the Thermal Properties of a PCM Window Panel

    Directory of Open Access Journals (Sweden)

    Martin Koláček

    2017-07-01

    Full Text Available This paper reports the experimental and simulation analysis of a window system incorporating Phase Change Materials (PCMs. In this study, the latent heat storage material is exploited to increase the thermal mass of the building component. A PCM-filled window can increase the possibilities of storage energy from solar radiation and reduce the heating cooling demand. The presented measurements were performed on a specific window panel that integrates a PCM. The PCM window panel consists of four panes of safety glass with three gaps, of which the first one contains a prismatic glass, the second a krypton gas, and the last one a PCM. New PCM window panel technology uses the placement of the PCM in the whole space of the window cavity. This technology improves the thermal performance and storage mass of the window panel. The results show the incongruent melting of salt hydrates and the high thermal inertia of the PCM window panel. The simulation data showed that the PCM window panel and the double glazing panel markedly reduced the peak temperature on the interior surface, reduced the air temperature inside the room, and also considerably improved the thermal mass of the building. This means that the heat energy entering the building through the panel is reduced by 66% in the summer cycle.

  4. Solar reflection panels

    Science.gov (United States)

    Diver, Jr., Richard B.; Grossman, James W [Albuquerque, NM; Reshetnik, Michael [Boulder, CO

    2006-07-18

    A solar collector comprising a glass mirror, and a composite panel, wherein the back of the mirror is affixed to a front surface of the composite panel. The composite panel comprises a front sheet affixed to a surface of a core material, preferably a core material comprising a honeycomb structure, and a back sheet affixed to an opposite surface of the core material. The invention may further comprise a sealing strip, preferably comprising EPDM, positioned between the glass mirror and the front surface of the composite panel. The invention also is of methods of making such solar collectors.

  5. Effect of microencapsulated phase change material in sandwich panels

    Energy Technology Data Exchange (ETDEWEB)

    Castellon, Cecilia; Medrano, Marc; Roca, Joan; Cabeza, Luisa F. [GREA Innovacio Concurrent, Edifici CREA, Universitat de Lleida, Pere de Cabrera s/n, 25001 Lleida (Spain); Navarro, Maria E.; Fernandez, Ana I. [Departamento de Ciencias de los Materiales e Ingenieria Metalurgica, Universitat de Barcelona, Marti i Franques 1, 08028 Barcelona (Spain); Lazaro, Ana; Zalba, Belen [Instituto de Investigacion en Ingenieria de Aragon, I3A, Grupo de Ingenieria Termica y Sistemas Energeticos (GITSE), Dpto. Ingenieria Mecanica, Area de Maquinas y Motores Termicos, Universidad de Zaragoza, Campus Politecnico Rio Ebro, Edificio ' ' Agustin de Betancourt,' ' Maria de Luna s/n, 50018 Zaragoza (Spain)

    2010-10-15

    Sandwich panels are a good option as building materials, as they offer excellent characteristics in a modular system. The goal of this study was to demonstrate the feasibility of using the microencapsulated PCM (Micronal BASF) in sandwich panels to increase their thermal inertia and to reduce the energy demand of the final buildings. In this paper, to manufacture the sandwich panel with microencapsulated PCM three different methods were tested. In case 1, the PCM was added mixing the microencapsulated PCM with one of the components of the polyurethane. In the other two cases, the PCM was added either a step before (case 2) or a step after (case 3) to the addition of the polyurethane to the metal sheets. The results show that in case 1 the effect of PCM was overlapped by a possible increase in thermal conductivity, but an increase of thermal inertia was found in case 3. In case 2, different results were obtained due to the poor distribution of the PCM. Some samples showed the effect of the PCM (higher thermal inertia), and other samples results were similar to the conventional sandwich panel. In both cases (2 and 3), it is required to industrialize the process to improve the results. (author)

  6. Creation and Implementation of an Outpatient Pathway for Atrial Fibrillation in the Emergency Department Setting: Results of an Expert Panel.

    Science.gov (United States)

    Baugh, Christopher W; Clark, Carol L; Wilson, Jason W; Stiell, Ian G; Kocheril, Abraham G; Luck, Krista K; Myers, Troy D; Pollack, Charles V; Roumpf, Steven K; Tomassoni, Gery F; Williams, James M; Patel, Brian B; Wu, Fred; Pines, Jesse M

    2018-03-10

    Atrial fibrillation and flutter (AF) is a common condition among emergency department (ED) patients in the United States. Traditionally, ED care for primary complaints related to AF focus on rate control, and patients are often admitted to an inpatient setting for further care. Inpatient care may include further telemetry monitoring and diagnostic testing, rhythm control, a search for identification of AF etiology, and stroke prophylaxis. However, many patients are eligible for safe and effective outpatient management pathways. They are widely used in Canada and other countries but less widely adopted in the United States. In this project, we convened an expert panel to create a practical framework for the process of creating, implementing, and maintaining an outpatient AF pathway for emergency physicians to assess and treat AF patients, safely reduce hospitalization rates, ensure appropriate stroke prophylaxis, and effectively transition patients to longitudinal outpatient treatment settings from the ED and/or observation unit. To support local pathway creation, the panel also reached agreement on a protocol development plan, a sample pathway, consensus recommendations for pathway components, sample pathway metrics, and a structured literature review framework using a modified Delphi technique by a technical expert panel of emergency medicine, cardiology, and other stakeholder groups. © 2018 by the Society for Academic Emergency Medicine.

  7. Component Functional Allocations of the ESF Multi-loop Controller for the KNICS ESF-CCS Design

    International Nuclear Information System (INIS)

    Hur, Seop; Choi, Jong Kyun; Kim, Dong Hoon; Kim, Ho; Kim, Seong Tae

    2006-01-01

    The safety related components in nuclear power plants are traditionally controlled by single-loop controllers. Traditional single-loop controller systems utilize dedicated processors for each component but that components independence is compromised through a sharing of power supplies, auxiliary logic modules and auxiliary I/O cards. In the new design of the ESF-CCS, the multi-loop controllers with data networks are widely used. Since components are assigned to ESF-CCS functional groups in a manner consistent with their process relationship, the effects of the failures are predictable and manageable. Therefore, the key issues for the design of multi-loop controller is to allocate the components to the each multi-loop controller through plant and function analysis and grouping. This paper deals with an ESF component functional allocation which is performed through allocation criteria and a fault analysis

  8. Proficiency testing for sensory profile panels : measuring panel performance

    NARCIS (Netherlands)

    Mcewan, J.A.; Hunter, E.A.; Gemert, L.J. van; Lea, P.

    2002-01-01

    Proficiency testing in sensory analysis is an important step towards demonstrating that results from one sensory panel are consistent with the results of other sensory panels. The uniqueness of sensory analysis poses some specific problems for measuring the proficiency of the human instrument

  9. Flight service evaluation of Kevlar-49 epoxy composite panels in wide-bodies commercial transport aircraft

    Science.gov (United States)

    Stone, R. H.

    1983-01-01

    Kevlar-49 fairing panels, installed as flight service components on three L-1011s, were inspected after 9 years of service. There are six Kevlar-49 panels on each aircraft: a left hand and right hand set of a wing body sandwich fairing; a solid laminate under wing fillet panel; and a 422 K (300 F) service aft engine fairing. The fairings have accumulated a total of 70,000 hours, with one ship set having over 24,000 hours service. The Kevlar-49 components were found to be performing satisfactorily in service with no major problems, or any condition requiring corrective action. The only defects noted were minor impact damage, a few minor disbonds and a minor degree of fastener hole fraying and elongation. These are for the most part comparable to damage noted on fiberglass fairings. The service history to date indicates that Kevlar-49 epoxy composite materials have satisfactory service characteristics for use in aircraft secondary structure.

  10. Family Medicine Panel Size with Care Teams: Impact on Quality.

    Science.gov (United States)

    Angstman, Kurt B; Horn, Jennifer L; Bernard, Matthew E; Kresin, Molly M; Klavetter, Eric W; Maxson, Julie; Willis, Floyd B; Grover, Michael L; Bryan, Michael J; Thacher, Tom D

    2016-01-01

    The demand for comprehensive primary health care continues to expand. The development of team-based practice allows for improved capacity within a collective, collaborative environment. Our hypothesis was to determine the relationship between panel size and access, quality, patient satisfaction, and cost in a large family medicine group practice using a team-based care model. Data were retrospectively collected from 36 family physicians and included total panel size of patients, percentage of time spent on patient care, cost of care, access metrics, diabetic quality metrics, patient satisfaction surveys, and patient care complexity scores. We used linear regression analysis to assess the relationship between adjusted physician panel size, panel complexity, and outcomes. The third available appointments (P size. Patient satisfaction, cost, and percentage fill rate were not affected by panel size. A physician-adjusted panel size larger than the current mean (2959 patients) was associated with a greater likelihood of poor-quality rankings (≤25th percentile) compared with those with a less than average panel size (odds ratio [OR], 7.61; 95% confidence interval [CI], 1.13-51.46). Increased panel size was associated with a longer time to the third available appointment (OR, 10.9; 95% CI, 1.36-87.26) compared with physicians with panel sizes smaller than the mean. We demonstrated a negative impact of larger panel size on diabetic quality results and available appointment access. Evaluation of a family medicine practice parameters while controlling for panel size and patient complexity may help determine the optimal panel size for a practice. © Copyright 2016 by the American Board of Family Medicine.

  11. Government auditing and corruption control: Evidence from China’s provincial panel data

    Directory of Open Access Journals (Sweden)

    Jin Liu

    2012-06-01

    Full Text Available Since its foundation, China’s government auditing system has played a very important role in maintaining financial and economic order and improving government accountability and transparency. Though a great deal of research has discussed the role of government auditing in discovering and deterring corruption, there is little empirical evidence on whether government auditing actually helps to reduce corruption. Using China’s provincial panel data from 1999 to 2008, this paper empirically examines the role of government auditing in China’s corruption control initiatives. Our findings indicate that the number of irregularities detected in government auditing is positively related to the corruption level in that province, which means the more severe the corruption is in a province, the more irregularities in government accounts are found by local audit institutions. Also, post-audit rectification effort is negatively related to the corruption level in that province, indicating that greater rectification effort is associated with less corruption. This paper provides empirical evidence on how government auditing can contribute to curbing corruption, which is also helpful for understanding the role of China’s local audit institutions in government governance and can enrich the literature on both government auditing and corruption control.

  12. Advanced control system for the scattering chamber of K-130 cyclotron

    International Nuclear Information System (INIS)

    Bhaumik, Tapas Kumar; Saha, Amiya Kumar; Mandal, Bidhan Chandra; Adak, Debabrata; Purkait, Monirul; Bhattacharya, Sailajananda

    2013-01-01

    The old relay based position control system of the Scattering Chamber of K-130 Cyclotron was more than 30 years old, developed multiple problems over the years, and the components of the control system like relays, potentiometers, limit switches, radiation resistant cables were not functioning as per specifications. It has been replaced recently by a new PLC based embedded control system. This has been developed using Advantech ADAM-5510EKW 16 bit CPU together with required I/O modules. MULTIPROG Basic V.4.6 has been used as programming software and Ladder Diagram has been used to realize control scheme of the PLC. A resistive type touch screen based operator panel, WebOP-2104VN4AE has been mounted on the control rack for local control. iFIX SCADA, 75 tags Runtime Version 5.1 has been used to operate from remote PC connected to the PLC by 70m CAT6 cable. The PLC communicates with the touch panel and remote PC through 100 Mbps Ethernet switch. The Graphical User Interfaces of the local control panel and the remote panel have been developed as per the requirement from the users. All the old sensors, limit switches, relays and cables have been replaced by new items. This paper reports about the development and commissioning of basic hardware, software and operation of the control system for last six months. (author)

  13. Large thermal protection system panel

    Science.gov (United States)

    Weinberg, David J. (Inventor); Myers, Franklin K. (Inventor); Tran, Tu T. (Inventor)

    2003-01-01

    A protective panel for a reusable launch vehicle provides enhanced moisture protection, simplified maintenance, and increased temperature resistance. The protective panel includes an outer ceramic matrix composite (CMC) panel, and an insulative bag assembly coupled to the outer CMC panel for isolating the launch vehicle from elevated temperatures and moisture. A standoff attachment system attaches the outer CMC panel and the bag assembly to the primary structure of the launch vehicle. The insulative bag assembly includes a foil bag having a first opening shrink fitted to the outer CMC panel such that the first opening and the outer CMC panel form a water tight seal at temperatures below a desired temperature threshold. Fibrous insulation is contained within the foil bag for protecting the launch vehicle from elevated temperatures. The insulative bag assembly further includes a back panel coupled to a second opening of the foil bag such that the fibrous insulation is encapsulated by the back panel, the foil bag, and the outer CMC panel. The use of a CMC material for the outer panel in conjunction with the insulative bag assembly eliminates the need for waterproofing processes, and ultimately allows for more efficient reentry profiles.

  14. Reflecting variable opening insulating panel

    International Nuclear Information System (INIS)

    Nungesser, W.T.

    1976-01-01

    A description is given of a reflecting variable opening insulating panel assembly, comprising a static panel assembly of reflecting insulation sheets forming a cavity along one side of the panel and a movable panel opening out by sliding from the cavity of the static panel, and a locking device for holding the movable panel in a position extending from the cavity of the static panel. This can apply to a nuclear reactor of which the base might require maintenance and periodical checking and for which it is desirable to have available certain processes for the partial dismantling of the insulation [fr

  15. Design, Manufacture, and Experimental Serviceability Validation of ITER Blanket Components

    Science.gov (United States)

    Leshukov, A. Yu.; Strebkov, Yu. S.; Sviridenko, M. N.; Safronov, V. M.; Putrik, A. B.

    2017-12-01

    In 2014, the Russian Federation and the ITER International Organization signed two Procurement Arrangements (PAs) for ITER blanket components: 1.6.P1ARF.01 "Blanket First Wall" of February 14, 2014, and 1.6.P3.RF.01 "Blanket Module Connections" of December 19, 2014. The first PA stipulates development, manufacture, testing, and delivery to the ITER site of 179 Enhanced Heat Flux (EHF) First Wall (FW) Panels intended for withstanding the heat flux from the plasma up to 4.7MW/m2. Two Russian institutions, NIIEFA (Efremov Institute) and NIKIET, are responsible for the implementation of this PA. NIIEFA manufactures plasma-facing components (PFCs) of the EHF FW panels and performs the final assembly and testing of the panels, and NIKIET manufactures FW beam structures, load-bearing structures of PFCs, and all elements of the panel attachment system. As for the second PA, NIKIET is the sole official supplier of flexible blanket supports, electrical insulation key pads (EIKPs), and blanket module/vacuum vessel electrical connectors. Joint activities of NIKIET and NIIEFA for implementing PA 1.6.P1ARF.01 are briefly described, and information on implementation of PA 1.6.P3.RF.01 is given. Results of the engineering design and research efforts in the scope of the above PAs in 2015-2016 are reported, and results of developing the technology for manufacturing ITER blanket components are presented.

  16. Coupled Thermo-Electro-Magneto-Elastic Response of Smart Stiffened Panels

    Science.gov (United States)

    Bednarcyk, Brett A.; Yarrington, Phillip W.

    2009-01-01

    This report documents the procedures developed for incorporating smart laminate and panel analysis capabilities within the HyperSizer aerospace structural sizing software package. HyperSizer analyzes stiffened panels composed of arbitrary composite laminates through stiffener homogenization, or "smearing " techniques. The result is an effective constitutive equation for the stiffened panel that is suitable for use in a full vehicle-scale finite element analysis via MSC/NASTRAN. The existing thermo-elastic capabilities of HyperSizer have herein been extended to include coupled thermo-electro-magneto-elastic analysis capabilities. This represents a significant step toward realization of design tools capable of guiding the development of the next generation of smart aerospace structures. Verification results are presented that compare the developed smart HyperSizer capability with an ABAQUS piezoelectric finite element solution for a facesheet-flange combination. These results show good agreement between HyperSizer and ABAQUS, but highlight a limitation of the HyperSizer formulation in that constant electric field components are assumed.

  17. COMDES-II: A Component-Based Framework for Generative Development of Distributed Real-Time Control Systems

    DEFF Research Database (Denmark)

    Ke, Xu; Sierszecki, Krzysztof; Angelov, Christo K.

    2007-01-01

    The paper presents a generative development methodology and component models of COMDES-II, a component-based software framework for distributed embedded control systems with real-time constraints. The adopted methodology allows for rapid modeling and validation of control software at a higher lev...... methodology for COMDES-II from a general perspective, describes the component models in details and demonstrates their application through a DC-Motor control system case study.......The paper presents a generative development methodology and component models of COMDES-II, a component-based software framework for distributed embedded control systems with real-time constraints. The adopted methodology allows for rapid modeling and validation of control software at a higher level...

  18. Considerations on FEM modeling in analyzing buckling and plastic collapse of a detection control; Boto panel no zakutsu sosei hokai kaiseki ni okeru FEM model ka ni kansuru kosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Yao, T; Fujikubo, M; Yanagihara, D; Irisawa, M [Hiroshima University, Hiroshima (Japan). Faculty of Engineering

    1997-10-01

    Buckling and plastic collapse of upper decks and bottom outer plates of a hull results directly in longitudinal bending collapse of the hull. Therefore, discussions were given on analysis for pressure destruction strength of a detection control panel which assumes an upper deck and a bottom outer plate. Pressure destruction behavior of the panting panel is a complex phenomenon accompanying non-linearity and geometrical non-linearity of the materials. Its whole phenomenon may be analyzed by using the finite element method (FEM) as a principle, but the analysis is not efficient. Therefore, considerations were given in relation to modeling when using the FEM. The considerations were given on a panel attached with flat steel panting members with respect to the modeling scope which considers the buckling mode according to the aspect ratio of the panel partitioned by the deflection control members. If the local buckling mode of the panel is an even number wave mode in the longitudinal direction, a triple span model is required. A modeling scope for a case of being subjected to water pressure and in-plane compression was considered on a panel attached with angle-type steel members having non-symmetric cross section. In this case, a triple bay model is more preferable to reproduce the behavior under water pressure loading. 1 ref., 6 figs.

  19. System requirements for one-time-use ENRAF control panel software

    International Nuclear Information System (INIS)

    HUBER, J.H.

    1999-01-01

    An Enraf Densitometer is installed on tank 241-AY-102. The Densitometer will frequently be tasked to obtain and log density profiles. The activity can be effected a number of ways. Enraf Incorporated provides a software package called ''Logger18'' to its customers for the purpose of in-shop testing of their gauges. Logger18 is capable of accepting an input file which can direct the gauge to obtain a density profile for a given tank level and bottom limit. Logger18 is a complex, DOS based program which will require trained technicians and/or tank farm entries to obtain the data. ALARA considerations have prompted the development of a more user-friendly, computer-based interface to the Enraf densitometers. This document records the plan by which this new Enraf data acquisition software will be developed, reviewed, verified, and released. This plan applies to the development and implementation of a one-time-use software program, which will be called ''Enraf Control Panel.'' The software will be primarily used for remote operation of Enraf Densitometers for the purpose of obtaining and logging tank product density profiles

  20. Puncture panel optimization

    International Nuclear Information System (INIS)

    Glass, R.E.; Longenbaugh, R.S.

    1986-01-01

    Sandia National Laboratories developed the TRansUranic PACkage Transporter (TRUPACT) to transport defense contact-handled transuranic wastes. The package has been designed to meet the normal and hypothetical accident conditions in 10CFR71 which includes the demonstrated ability to survive a 1-meter drop onto a mild steel pin. The puncture protection is provided by puncture resistant panels. In conjunction with the development of TRUPACT, a series of experiments has been conducted to reduce the weight of the puncture resistant panels. The initial scoping tests resulted in a preliminary design incorporating 30 layers of Kevlar. This design has been shown to meet the regulatory puncture test. To reduce the weight of this panel, subscale tests were conducted on panels utilizing Kevlar yarns with varying mass per unit length (denier) as well as different resins. This paper reviews the testing undertaken in the original panel development and discusses the results obtained from the recent subscale and full-scale optimization tests

  1. Hepatic (Liver) Function Panel

    Science.gov (United States)

    ... Educators Search English Español Blood Test: Hepatic (Liver) Function Panel KidsHealth / For Parents / Blood Test: Hepatic (Liver) ... kidneys ) is working. What Is a Hepatic (Liver) Function Panel? A liver function panel is a blood ...

  2. Long Duration Balloon Charge Controller Stack Integration

    Science.gov (United States)

    Clifford, Kyle

    NASA and the Columbia Scientific Balloon Facility are interested in updating the design of the charge controller on their long duration balloon (LDB) in order to enable the charge controllers to be directly interfaced via RS232 serial communication by a ground testing computers and the balloon's flight computer without the need to have an external electronics stack. The design involves creating a board that will interface with the existing boards in the charge controller in order to receive telemetry from and send commands to those boards, and interface with a computer through serial communication. The inputs to the board are digital status inputs indicating things like whether the photovoltaic panels are connected or disconnected; and analog inputs with information such as the battery voltage and temperature. The outputs of the board are 100ms duration command pulses that will switch relays that do things like connect the photovoltaic panels. The main component of this design is a PIC microcontroller which translates the outputs of the existing charge controller into serial data when interrogated by a ground testing or flight computer. Other components involved in the design are an AD7888 12-bit analog to digital converter, a MAX3232 serial transceiver, various other ICs, capacitors, resistors, and connectors.

  3. Analysis of 3-panel and 4-panel microscale ionization sources

    International Nuclear Information System (INIS)

    Natarajan, Srividya; Parker, Charles B.; Glass, Jeffrey T.; Piascik, Jeffrey R.; Gilchrist, Kristin H.; Stoner, Brian R.

    2010-01-01

    Two designs of a microscale electron ionization (EI) source are analyzed herein: a 3-panel design and a 4-panel design. Devices were fabricated using microelectromechanical systems technology. Field emission from carbon nanotube provided the electrons for the EI source. Ion currents were measured for helium, nitrogen, and xenon at pressures ranging from 10 -4 to 0.1 Torr. A comparison of the performance of both designs is presented. The 4-panel microion source showed a 10x improvement in performance compared to the 3-panel device. An analysis of the various factors affecting the performance of the microion sources is also presented. SIMION, an electron and ion optics software, was coupled with experimental measurements to analyze the ion current results. The electron current contributing to ionization and the ion collection efficiency are believed to be the primary factors responsible for the higher efficiency of the 4-panel microion source. Other improvements in device design that could lead to higher ion source efficiency in the future are also discussed. These microscale ion sources are expected to find application as stand alone ion sources as well as in miniature mass spectrometers.

  4. Brakes, brake control and driver assistance systems function, regulation and components

    CERN Document Server

    2014-01-01

    Braking systems have been continuously developed and improved throughout the last years. Major milestones were the introduction of antilock braking system (ABS) and electronic stability program. This reference book provides a detailed description of braking components and how they interact in electronic braking systems. Contents Motor vehicle safety.- Basic principles of vehicle dynamics.- Car braking systems.- Car braking-system components.- Wheel brakes.- Antilock breaking systems.- Traction control system.- Electronic stability program.- Automatic brake functions.- Hydraulic modulator.- Sensors for brake control.- Sensotronic brake control.- Active steering.- Occupant protection systems.- Driver assistance systems.- Adaptive cruise control.- Parking systems.- Instrumentation.- Orientation methods.- Navigation systems.- Workshop technology. The target groups Motor-vehicle technicians in education and vocational training Master-mechanics and technicians in garage-workshops Teachers and lecturers in vocation...

  5. Report of panel 1: The appropriate scope and mission of ITER

    Energy Technology Data Exchange (ETDEWEB)

    Linford, R.K. (Los Alamos National Lab., NM (United States)); Weitzner, H.; Abdou, M.A.; Baldwin, D.E.; Berkner, K.H.; Berry, L.A.; Culler, F.L.; Dean, S.O.; DeFreece, D.A.; Gauster, W.B. (and others)

    1992-12-01

    This panel looked at the mission of ITER, and how the US should address the present plans, and considers a number of alternative plans to arrive at the eventual goals of ITER. The panel considered three major approaches which have been discussed on the international scale, and tries to present the strengths, weaknesses, and possible changes to these plans. It suggests that any of these plans can arrive at the eventual aim, but may involve differing risks and time commitments. All plans involve ITER design studies, development work on technologies which must be in place for ITER design to succeed, and testing of materials and components for application in the device.

  6. Report of panel 1: The appropriate scope and mission of ITER

    International Nuclear Information System (INIS)

    Linford, R.K.; Weitzner, H.; Abdou, M.A.; Baldwin, D.E.; Berkner, K.H.; Berry, L.A.; Culler, F.L.; Dean, S.O.; DeFreece, D.A.; Gauster, W.B.

    1992-01-01

    This panel looked at the mission of ITER, and how the US should address the present plans, and considers a number of alternative plans to arrive at the eventual goals of ITER. The panel considered three major approaches which have been discussed on the international scale, and tries to present the strengths, weaknesses, and possible changes to these plans. It suggests that any of these plans can arrive at the eventual aim, but may involve differing risks and time commitments. All plans involve ITER design studies, development work on technologies which must be in place for ITER design to succeed, and testing of materials and components for application in the device

  7. Identification of a novel panel of cerebrospinal fluid biomarkers for Alzheimer's disease

    DEFF Research Database (Denmark)

    Simonsen, A.H.; McGuire, J.; Podust, V.N.

    2008-01-01

    samples from AD patients (n=95) and population-based healthy controls (n=72) were analyzed by SELDI-TOF-MS in order to discover and characterize novel candidate biomarker combinations that differentiate AD patients from normal aging in this explorative study. Thirty candidate biomarkers (ROC AUC>0.7) were...... healthy control individuals with high sensitivity (97%) and specificity (98%). The panel of five markers was tested on a blinded independent data set of 30 AD samples and 28 controls giving 100% sensitivity and 97% specificity. This novel panel of biomarkers could potentially be used to improve...

  8. Concrete Flow in Diaphragm Wall Panels : A Full-Scale In-Situ Test

    NARCIS (Netherlands)

    Van Dalen, J.H.; Bosch, J.W.; Broere, W.

    2015-01-01

    Flow processes, taking place during the concreting of diaphragm wall panels (D-wall panels), are of great importance for the quality of the wall. During this phase, the bentonite, present in the excavated trench, should be completely replaced by concrete in a controlled way. In literature several

  9. Antinuclear antibody panel

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003535.htm Antinuclear antibody panel To use the sharing features on this page, please enable JavaScript. The antinuclear antibody panel is a blood test that looks at ...

  10. Hepatitis virus panel

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003558.htm Hepatitis virus panel To use the sharing features on this page, please enable JavaScript. The hepatitis virus panel is a series of blood tests used ...

  11. A Novel Technique to Obtain the Health of a PV Panel

    DEFF Research Database (Denmark)

    Hussain, Dil Muhammad Akbar; Imran, Raja Muhammad; Shoro, Ghulam Mustafa

    2014-01-01

    Power efficiency delivered from a PV panel individually or as larger system for example a PV Solar Form is very much dependent upon many factors for example irradiance, temperature, shadowing and the health of individual PV panels/cells. The first two factors are typically beyond the control...... of designer/engineers but certainly if we can determine shading and early diagnoses about the health of a panel/cell we can quickly fix such issues so that system delivers normal power production for which it is designed and maintains the required power efficiency....

  12. REINFORCED COMPOSITE PANEL

    DEFF Research Database (Denmark)

    2003-01-01

    A composite panel having front and back faces, the panel comprising facing reinforcement, backing reinforcement and matrix material binding to the facing and backing reinforcements, the facing and backing reinforcements each independently comprising one or more reinforcing sheets, the facing rein...... by matrix material, the facing and backing reinforcements being interconnected to resist out-of-plane relative movement. The reinforced composite panel is useful as a barrier element for shielding structures, equipment and personnel from blast and/or ballistic impact damage....

  13. Model of a photovoltaic panel emulator in MATLAB-Simulink

    OpenAIRE

    CAN, Hayrettin

    2014-01-01

    Being able to behave electrically similar to photovoltaic (PV) panels, PV emulator systems make it possible to perform different PV system tests under various operation conditions. In this paper, a model of a PV panel emulator is presented using the Power System Blockset under MATLAB-Simulink. The simulation of the emulator system is developed for testing a controller prior to a real-time implementation. The model can handle the dependence of all of the parameters in the model with ...

  14. Estimation of Fractionally Integrated Panels with Fixed Effects and Cross-Section Dependence

    DEFF Research Database (Denmark)

    Ergemen, Yunus Emre; Velasco, Carlos

    We consider large N, T panel data models with fixed effects, common factors allowing cross-section dependence, and persistent data and shocks, which are assumed fractionally integrated. In a basic setup, the main interest is on the fractional parameter of the idiosyncratic component, which...

  15. Vibration characteristics of an inclined flip-flow screen panel in banana flip-flow screens

    Science.gov (United States)

    Xiong, Xiaoyan; Niu, Linkai; Gu, Chengxiang; Wang, Yinhua

    2017-12-01

    A banana flip-flow screen is an effective solution for the screening of high-viscosity, high-water and fine materials. As one of the key components, the vibration characteristics of the inclined flip-flow screen panel largely affects the screen performance and the processing capacity. In this paper, a mathematical model for the vibration characteristic of the inclined flip-flow screen panel is proposed based on Catenary theory. The reasonability of Catenary theory in analyzing the vibration characteristic of flip-flow screen panels is verified by a published experiment. Moreover, the effects of the rotation speed of exciters, the incline angle, the slack length and the characteristics of the screen on the vertical deflection, the vertical velocity and the vertical acceleration of the screen panel are investigated parametrically. The results show that the rotation speed of exciters, the incline angle, the slack length and the characteristics of the screen have significant effects on the vibrations of an inclined flip-flow screen panel, and these parameters should be optimized.

  16. Rational Design of Composite Panels

    DEFF Research Database (Denmark)

    Riber, Hans Jørgen

    1996-01-01

    A non-linear structural model for composite panels is presented. The non-linear terms in the lateral displacements are modelled as an additional set of lateral loads acting on the panel. Hence the solution is reduced to that of an equivalent panel with small displacements In order to treat sandwich...... Norske Veritas', DNV, building rules concerning high-speed light craft, in which the panel scantlings are often restricted by a maximum lateral deflection connected with the panel span....

  17. Spacecraft with gradual acceleration of solar panels

    Science.gov (United States)

    Merhav, Tamir R. (Inventor); Festa, Michael T. (Inventor); Stetson, Jr., John B. (Inventor)

    1996-01-01

    A spacecraft (8) includes a movable appendage such as solar panels (12) operated by a stepping motor (28) driven by pulses (311). In order to reduce vibration andor attitude error, the drive pulses are generated by a clock down-counter (312) with variable count ratio. Predetermined desired clock ratios are stored in selectable memories (314a-d), and the selected ratio (R) is coupled to a comparator (330) together with the current ratio (C). An up-down counter (340) establishes the current count-down ratio by counting toward the desired ratio under the control of the comparator; thus, a step change of solar panel speed never occurs. When a direction change is commanded, a flag signal generator (350) disables the selectable memories, and enables a further store (360), which generates a count ratio representing a very slow solar panel rotational rate, so that the rotational rate always slows to a low value before direction is changed. The principles of the invention are applicable to any movable appendage.

  18. Composite panel development at JPL

    Science.gov (United States)

    Mcelroy, Paul; Helms, Rich

    1988-01-01

    Parametric computer studies can be use in a cost effective manner to determine optimized composite mirror panel designs. An InterDisciplinary computer Model (IDM) was created to aid in the development of high precision reflector panels for LDR. The materials properties, thermal responses, structural geometries, and radio/optical precision are synergistically analyzed for specific panel designs. Promising panels designs are fabricated and tested so that comparison with panel test results can be used to verify performance prediction models and accommodate design refinement. The iterative approach of computer design and model refinement with performance testing and materials optimization has shown good results for LDR panels.

  19. A quality improvement project using statistical process control methods for type 2 diabetes control in a resource-limited setting.

    Science.gov (United States)

    Flood, David; Douglas, Kate; Goldberg, Vera; Martinez, Boris; Garcia, Pablo; Arbour, MaryCatherine; Rohloff, Peter

    2017-08-01

    Quality improvement (QI) is a key strategy for improving diabetes care in low- and middle-income countries (LMICs). This study reports on a diabetes QI project in rural Guatemala whose primary aim was to improve glycemic control of a panel of adult diabetes patients. Formative research suggested multiple areas for programmatic improvement in ambulatory diabetes care. This project utilized the Model for Improvement and Agile Global Health, our organization's complementary healthcare implementation framework. A bundle of improvement activities were implemented at the home, clinic and institutional level. Control charts of mean hemoglobin A1C (HbA1C) and proportion of patients meeting target HbA1C showed improvement as special cause variation was identified 3 months after the intervention began. Control charts for secondary process measures offered insights into the value of different components of the intervention. Intensity of home-based diabetes education emerged as an important driver of panel glycemic control. Diabetes QI work is feasible in resource-limited settings in LMICs and can improve glycemic control. Statistical process control charts are a promising methodology for use with panels or registries of diabetes patients. © The Author 2017. Published by Oxford University Press in association with the International Society for Quality in Health Care. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  20. Component fragilities. Data collection, analysis and interpretation

    International Nuclear Information System (INIS)

    Bandyopadhyay, K.K.; Hofmayer, C.H.

    1985-01-01

    As part of the component fragility research program sponsored by the US NRC, BNL is involved in establishing seismic fragility levels for various nuclear power plant equipment with emphasis on electrical equipment. To date, BNL has reviewed approximately seventy test reports to collect fragility or high level test data for switchgears, motor control centers and similar electrical cabinets, valve actuators and numerous electrical and control devices, e.g., switches, transmitters, potentiometers, indicators, relays, etc., of various manufacturers and models. BNL has also obtained test data from EPRI/ANCO. Analysis of the collected data reveals that fragility levels can best be described by a group of curves corresponding to various failure modes. The lower bound curve indicates the initiation of malfunctioning or structural damage, whereas the upper bound curve corresponds to overall failure of the equipment based on known failure modes occurring separately or interactively. For some components, the upper and lower bound fragility levels are observed to vary appreciably depending upon the manufacturers and models. For some devices, testing even at the shake table vibration limit does not exhibit any failure. Failure of a relay is observed to be a frequent cause of failure of an electrical panel or a system. An extensive amount of additional fregility or high level test data exists

  1. Residential water demand and water consumption: an econometric analysis on municipal panel data

    International Nuclear Information System (INIS)

    Musolesi, Antonio; Nosvelli, Mario

    2005-01-01

    This paper focuses on residential water demand estimation, a rather neglected issue in the Italian environmental economics literature as compared to other European countries and the USA. This may depend on the difficulties in gathering proper data and, most of all, panel data. In some cases statistical information are not suitably collected, while in other cases legal privacy ties put some obstacles to data set transfer. Our panel data set refers to 102 municipalities in Lombardy (Italy) for the period 1998-2002. When estimating the effect of water price, we control for other relevant variables such as: income, households demographical variables - (age structure, number of component for each family) number of firms in tertiary sector, water system length. In the considered period, the data show both an increase in population (1,5 %) and in the number of water consumers (7%) associated, on aggregate, with a slight reduction in water consumption (-1,1 %). Water demand models are estimated both in a static and in a dynamic framework. In the former, the emphasis is set on the sources of endogeneity in the average price by estimating a system of simultaneous equations and relevant variables for assessing consumer behaviour - such as socio demographic ones - are incorporated in the model. In the latter, econometric methods especially designed for endogeneity in panel data models (Arellano e Bond, 1991), are employed in order to estimate the long run elasticity of water demand with respect to average price. We find evidence both that consumers significantly respond to average price only in the long run with an elasticity of about - 0,3-0,4 and that income and demographic variables are crucial in explaining consumers' behaviour. Furthermore, water consumption presents a strong auto-regressive component, showing the emergence of inertia and path dependency in consumption habits. Such results suggest important implications for water policy planning. On one side demographic

  2. Computer control of the high-voltage power supply for the DIII-D electron cyclotron heating system

    International Nuclear Information System (INIS)

    Clow, D.D.; Kellman, D.H.

    1992-01-01

    This paper reports on the DIII-D Electron Cyclotron Heating (ECH) high voltage power supply which is controlled by a computer. Operational control is input via keyboard and mouse, and computer/power supply interfact is accomplished with a Computer Assisted Monitoring and Control (CAMAC) system. User-friendly tools allow the design and layout of simulated control panels on the computer screen. Panel controls and indicators can be changed, added or deleted, and simple editing of user-specific processes can quickly modify control and fault logic. Databases can be defined, and control panel functions are easily referred to various data channels. User-specific processes are written and linked using Fortran, to manage control and data acquisition through CAMAC. The resulting control system has significant advantages over the hardware it emulates: changes in logic, layout, and function are quickly and easily incorporated; data storage, retrieval, and processing are flexible and simply accomplished; physical components subject to wear and degradation are minimized. In addition, the system can be expanded to multiplex control of several power supplies, each with its own database, through a single computer console

  3. Variable setpoint as a relaxing component in physiological control.

    Science.gov (United States)

    Risvoll, Geir B; Thorsen, Kristian; Ruoff, Peter; Drengstig, Tormod

    2017-09-01

    Setpoints in physiology have been a puzzle for decades, and especially the notion of fixed or variable setpoints have received much attention. In this paper, we show how previously presented homeostatic controller motifs, extended with saturable signaling kinetics, can be described as variable setpoint controllers. The benefit of a variable setpoint controller is that an observed change in the concentration of the regulated biochemical species (the controlled variable) is fully characterized, and is not considered a deviation from a fixed setpoint. The variation in this biochemical species originate from variation in the disturbances (the perturbation), and thereby in the biochemical species representing the controller (the manipulated variable). Thus, we define an operational space which is spanned out by the combined high and low levels of the variations in (1) the controlled variable, (2) the manipulated variable, and (3) the perturbation. From this operational space, we investigate whether and how it imposes constraints on the different motif parameters, in order for the motif to represent a mathematical model of the regulatory system. Further analysis of the controller's ability to compensate for disturbances reveals that a variable setpoint represents a relaxing component for the controller, in that the necessary control action is reduced compared to that of a fixed setpoint controller. Such a relaxing component might serve as an important property from an evolutionary point of view. Finally, we illustrate the principles using the renal sodium and aldosterone regulatory system, where we model the variation in plasma sodium as a function of salt intake. We show that the experimentally observed variations in plasma sodium can be interpreted as a variable setpoint regulatory system. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  4. TWRS vadose zone contamination issue expert panel report

    Energy Technology Data Exchange (ETDEWEB)

    Shafer, D.S.

    1997-05-01

    -imposed. The institutional problems they encountered include having both Tank Waste Remediation System (TWRS), the parent organization of the Vadose Zone Characterization Program and Environmental Restoration (ER), each under different regulatory controls and different organizational units, seeking to defend the status quo and discount many of the Panel`s conclusions and recommendations. The results presented in the SX Tank Farm Report, especially the visualizations, have created concern in the public sector, both on a local, personal level and on a national political level.

  5. Supersonic Panel Flutter Test Results for Flat Fiber-Glass Sandwich Panels with Foamed Cores

    Science.gov (United States)

    Tuovila, W. J.; Presnell, John G., Jr.

    1961-01-01

    Flutter tests have been made on flat panels having a 1/4 inch-thick plastic-foam core covered with thin fiber-glass laminates. The testing was done in the Langley Unitary Plan wind tunnel at Mach numbers from 1.76 t o 2.87. The flutter boundary for these panels was found to be near the flutter boundary of thin metal panels when compared on the basis of an equivalent panel stiffness. The results also demonstrated that the depth of the cavity behind the panel has a pronounced influence on flutter. Changing the cavity depth from 1 1/2 inches to 1/2 inch reduced the dynamic pressure at start of flutter by 40 percent. No flutter was obtained when the spacers on the back of the panel were against the bottom of the cavity.

  6. Panel Resource Management (PRM) Implementation and Effects within Safety Review Panel Settings and Dynamics

    Science.gov (United States)

    Taylor, Robert W.; Nash, Sally K.

    2007-01-01

    While technical training and advanced degree's assure proficiency at specific tasks within engineering disciplines, they fail to address the potential for communication breakdown and decision making errors familiar to multicultural environments where language barriers, intimidating personalities and interdisciplinary misconceptions exist. In an effort to minimize these pitfalls to effective panel review, NASA's lead safety engineers to the ISS Safety Review Panel (SRP), and Payload Safety Review Panel (PSRP) initiated training with their engineers, in conjunction with the panel chairs, and began a Panel Resource Management (PRM) program. The intent of this program focuses on the ability to reduce the barriers inhibiting effective participation from all panel attendees by bolstering participants confidence levels through increased communication skills, situational awareness, debriefing, and a better technical understanding of requirements and systems.

  7. Mechanical components design for PWR - control rod drive mechanism

    International Nuclear Information System (INIS)

    Leme, Francisco Louzano; Mattar Neto, Miguel

    2002-01-01

    The Control Rod Drive Mechanism (CRDM) is usually - a high precision - equipment incorporating mechanical and electrical components designed to move the control rods. The 'control rods' refer to all rods or assemblies that are moved to assess the performance of the reactor. The CRDM here presented is the Nut and Lead Screw type. This type is basically a power screw type magnetically coupled to a slow speed reluctance electric motor that provides a means of axially positioning the movable fuel assemblies in the reactor core for purpose of controlling core reactivity. A helically threaded lead screw assembly, comprising one element of power screw, is attached to a movable fuel assemblies. The CRDM usually has closer and more consistent contact with environment peculiar to the reactor than has only other machinery component. This environment includes not only the radiation field of the reactor, but also the temperature, pressure and chemical properties associated with the material used as the coolant for reactor fuel. Specific and special materials are needed because of the above mentioned application. Due to the importance of the above described CRDM functions, this paper will also consider the nuclear functions and their safety classes as well as the CRDM nuclear design criteria. (author)

  8. Solar panel cleaning robot

    Science.gov (United States)

    Nalladhimmu, Pavan Kumar Reddy; Priyadarshini, S.

    2018-04-01

    As the demand of electricity is increasing, there is need to using the renewable sources to produce the energy at present of power shortage, the use of solar energy could be beneficial to great extent and easy to get the maximum efficiency. There is an urgent in improving the efficiency of solar power generation. Current solar panels setups take a major power loss when unwanted obstructions cover the surface of the panels. To make solar energy more efficiency of solar array systems must be maximized efficiency evaluation of PV panels, that has been discussed with particular attention to the presence of dust on the efficiency of the PV panels have been highlighted. This paper gives the how the solar panel cleaning system works and designing of the cleaning system.

  9. Capacity analysis of amortization of energy and environmental liabilities photovoltaic panels

    International Nuclear Information System (INIS)

    Tiago Filho, Geraldo Lucio; Adriano Rosa, Carlos

    2011-01-01

    The claim that the use of solar energy through photovoltaic (PV) panels is a clean energy source is based, in most cases, considering only the generation of electricity by the group after manufacture and installation. Without considering the process of manufacture, neither more nor less CO2 emissions are produced, and other degradation environment, which vary according to the country's energy matrix in which these activities develop. This article uses analysis tools to study the impacts of life cycle environment that have passed since the exploitation of mineral deposits used in the manufacture of major components for the manufacture of the panel. In this study adds to quantify the emissions of various gases, emitted in the manufacturing process of photovoltaic modules, expressed in equivalent tons of CO2, resulting from the process and depending on the country in which the panel is manufactured and the depreciation of environmental liabilities, to allow life determination (author)

  10. Experiments of cooling photovoltaic panel by desorption process; Dacchaku hanno wo riyoshita taiyoko hatsuden panel no ondo josho yokusei jikken

    Energy Technology Data Exchange (ETDEWEB)

    Akisawa, A; Inoue, S; Kashiwagi, T [Tokyo University of Agriculture and Technology, Tokyo (Japan)

    1997-11-25

    It is important to cool a photovoltaic (PV) panel, because increased panel temperature is accompanied by decreased power generation efficiency. The authors have proposed a PV power generation system combined with an adsorption chiller driven by low-temperature heat, and simulated temperature changes during the desorption cycle, where the chiller utilizes endothermic reactions of an adsorbent during the desorption cycle. Described herein are results of the tests carried out to validate possibility of controlling panel temperature increase. The system consists of the PV panel with which a bed packed with an adsorbent is monolithically combined, condenser and evaporator. It generates power during the daytime by sunbeams, and provides low-temperature heat during the nighttime by the evaporator. In particular, ice can be produced when methanol and activated coal are used as the adsorbate and adsorbent. It has an advantage of effective utilization of energy as the heat source, which has been merely dissipated by the conventional system in the air. Such a system is expected to be useful for promoting effective utilization of solar energy and for peak power shaving in summer. The initial targets are achieved by the tests. 4 refs., 10 figs.

  11. Using a Fuzzy Light Sensor to Improve the Efficiency of Solar Panels

    Science.gov (United States)

    Suryono; Suseno, Jatmiko Endro; Sulistiati, Ainie Khuriati Riza; Prahara, Tahan

    2018-02-01

    Solar panel efficiency can be increased by improving the quality of photovoltaic material, the effectiveness of electronic circuit, and the light source tracking model. This research is aimed at improving the quality of solar panels by tracking light source using a fuzzy logic sensor. A fuzzy light sensor property is obtained from two LDR (light dependent resistor) light sensors installed in parallel to each other and is given a light separator in between them. Both sensors are mounted on a solar panel. Sensor output is acquired using a 12 bit ADC from an ATSAM3XE microcontroller and is then sent to a computer using WIFI radio. A PID (Proportional-Integral-Derivative) control algorithm is used to manage the position of the solar panel in line with the input given by the fuzzy light sensor. This control mechanism works based on the margin of fuzzy membership from both sensors that is used to move a motor DC that in turn moves the solar panel. Experimental results show a characteristically symmetrical fuzzy membership of both sensors with a reflected correlation of R=0.9981 after gains from both sensors are arranged with a program. Upon being tested in the field, this system was capable of improving the performance of solar panels in gaining power compared to their original fixed position. The discrepancy was evident when the angle of incoming sunlight approached both 0° and 180°. Further calculations of data acquired by the fuzzy light sensor show increased solar panel power efficiency by up to 5.6%.

  12. Lightweight, Thermally Insulating Structural Panels

    Science.gov (United States)

    Eisen, Howard J.; Hickey, Gregory; Wen, Liang-Chi; Layman, William E.; Rainen, Richard A.; Birur, Gajanana C.

    1996-01-01

    Lightweight, thermally insulating panels that also serve as structural members developed. Honeycomb-core panel filled with low-thermal-conductivity, opacified silica aerogel preventing convection and minimizes internal radiation. Copper coating on face sheets reduces radiation. Overall thermal conductivities of panels smaller than state-of-art commercial non-structurally-supporting foam and fibrous insulations. On Earth, panels suitable for use in low-air-pressure environments in which lightweight, compact, structurally supporting insulation needed; for example, aboard high-altitude aircraft or in partially evacuated panels in refrigerators.

  13. PERBANDINGAN UNJUK KERJA ANTARA PANEL SEL SURYA BERPENJEJAK DENGAN PANEL SEL SURYA DIAM

    OpenAIRE

    Syafaruddin Ch

    2010-01-01

    The ability to produce electrical energy at Solar Power Plant  is highly dependent on the magnitude and duration of sun exposure on the solar cell panels. The movement of the sun from east to west that periodicity in every day is a problem at  the  optimization generation of electricity at  Solar Power Plant   if using solar panel that motionless. This is because the solar cell panel can not catch the maximum sun exposure. To solve the above problem then designed a solar cell panel  tracker...

  14. Panel session: Disposal of HLW - ready for implementation

    International Nuclear Information System (INIS)

    Heremans, R.; Come, B.; Barbreau, A.; Girardi, F.

    1986-01-01

    The paper is a report of a panel session at the European Community conference on radioactive waste management and disposal, Luxembourg 1985, concerning the safe and long-term disposal of high-activity and long-lived waste. The subjects discussed include: geological barriers including deep sea-bed sediments, engineered barriers, technological problems (repository construction, waste emplacement, backfilling and sealing), safety analysis, performance assessment of disposal system components, and finally institutional, legal and financial aspects of geological disposal. (U.K.)

  15. Panel data analysis using EViews

    CERN Document Server

    Agung, I Gusti Ngurah

    2013-01-01

    A comprehensive and accessible guide to panel data analysis using EViews software This book explores the use of EViews software in creating panel data analysis using appropriate empirical models and real datasets. Guidance is given on developing alternative descriptive statistical summaries for evaluation and providing policy analysis based on pool panel data. Various alternative models based on panel data are explored, including univariate general linear models, fixed effect models and causal models, and guidance on the advantages and disadvantages of each one is given. Panel Data Analysis

  16. Analysis and Design of CLL Resonant Converter for Solar Panel-battery Systems

    OpenAIRE

    D.Ramasubramanian; C.Nagarajan; M.Muruganandam

    2012-01-01

    This paper presents a CLL resonant converter with DSP based Fuzzy Logic Controller (FLC) for solar panel to battery charging system. The mathematical model of the converters has been developed and simulated using MATLAB. The state space model of the converter is developed; it is used to analysis the steady state stability of the system. The aim of the proposed converter is to regulate and control of the output voltage from the solar panel voltage. The performance of the proposed converter is ...

  17. RECIPANEL: RECYCLED PAPER PANELS

    Directory of Open Access Journals (Sweden)

    HERNÁN CAÑOLA

    2012-01-01

    Full Text Available En este artículo se estudia la fabricación y el comportamiento mecánico de paneles a base de papel reciclado. El objetivo principal del proyecto es producir un prototipo de panel que emplee elementos provenientes de residuos sólidos (papel periódico y de un material conglomerante (cemento Portland blanco. El panel debe ser económico, debe tener buenas propiedades mecánicas y debe tener dimensiones comerciales para su uso en muros tabiques y en cielos falsos en la industria de la construcción. El Recipanel es un panel no estructural a base de papel reciclado. El Recipanel cumple las normas colombianas en lo relativo a los paneles de uso no estructural y presenta además unas excelentes características mecánicas.

  18. Performance of PV panels for solar energy conversion at the South Pole

    Science.gov (United States)

    Peeran, Syed M.

    Expanding research facilities at the Amundson-Scott South pole station require increased electric power generation. Presently, electric power generation is by diesel generators using the JP8 fuel. As the station is accessible only for a short supply period during the austral summer, there are limitations upon the supply of fuel for power generation. This makes it necessary to seriously consider the use of the renewable energy sources. Although there is no sunlight for six months in the year, abundant solar energy is available during the remaining 6 months because of the clear skies, the clarity of air and the low humidity at the south pole. As the buildings at the south pole are built either without windows or with only porthole type windows, large areas on the walls and the roof are available for mounting the photovoltaic (PV) panels. In addition there is unlimited space around the station for constructing a PV panel 'farm'. In this paper four types of PV panels are evaluated; the 2-axis tracking panels, vertical 1-axis tracking panels, fixed vertical panels on the walls of buildings and mounted outdoors, and fixed horizontal panels on the roofs of the buildings. Equations are developed for the power output in KW/sq. ft and annual energy in kWh/sq. ft for each type of panel. The equations include the effects of the inclination of the sun above the horizon, the movement of the sun around the horizon, the direct, reflected and diffused components of the solar radiation, the characteristics of the solar cells and the types of dc/ac inverters used to interface the output of the cells with the existing ac power. A conceptual design of a 150-kW PV generation system suitable for the south pole is also discussed in this paper.

  19. Component and prototype panel testing of the mini-dome Fresnel lens photovoltaic concentrator array

    Science.gov (United States)

    Piszczor, Michael F.; Swartz, Clifford K.; O'Neill, Mark J.

    1990-01-01

    The mini-dome Fresnel lens concentrator array, a high-efficiency, lightweight space photovoltaic array concept, is described. The three critical elements of the array concept are the Fresnel lens concentrator, the prismatic cell power cover, and the photovoltaic cell. Prototype concentrator lenses have been fabricated and tested, with optical efficiencies reaching 90 percent. Work is progressing on the design and fabrication of the panel structure. The impact of recent advances in 30 percent-efficient multijunction photovoltaic cells on array performance is also discussed. Near-term performance goals of 300 w/sq m and 100 w/kg are now feasible.

  20. Wind pressure testing of tornado safe room components made from wood

    Science.gov (United States)

    Robert Falk; Deepak Shrestha

    2016-01-01

    To evaluate the ability of a wood tornado safe room to resist wind pressures produced by a tornado, two safe room com-ponents were tested for wind pressure strength. A tornado safe room ceiling panel and door were static-pressure-tested according to ASTM E 330 using a vacuum test system. Re-sults indicate that the panels had load capacities from 2.4 to 3.5 times that...

  1. Vibration Damping Via Acoustic Treatment Attached To Vehicle Body Panels

    Science.gov (United States)

    Gambino, Carlo

    Currently, in the automotive industry, the control of noise and vibration is the subject of much research, oriented towards the creation of innovative solutions to improve the comfort of the vehicle and to reduce its cost and weight. This thesis fits into this particular framework, as it aims to investigate the possibility of integrating the functions of sound absorptioninsulation and vibration damping in a unique component. At present the bituminous viscoelastic treatments, which are bonded to the car body panels, take charge of the vibration damping, while the sound absorption and insulation is obtained by means of the poroacoustic treatments. The solution proposed here consists of employing porous materials to perform both these functions, thus allowing the partial or complete removal of the viscoelastic damping treatments from the car body. This should decrease the weight of the vehicle, reducing fuel consumption and emissions, and it might also benefit production costs.

  2. Piezoelectric Shunt Vibration Damping of F-15 Panel under High Acoustic Excitation

    Science.gov (United States)

    Wu, Shu-Yau; Turner, Travis L.; Rizzi, Stephen A.

    2000-01-01

    At last year's SPIE symposium, we reported results of an experiment on structural vibration damping of an F-15 underbelly panel using piezoelectric shunting with five bonded PZT transducers. The panel vibration was induced with an acoustic speaker at an overall sound pressure level (OASPL) of about 90 dB. Amplitude reductions of 13.45 and 10.72 dB were achieved for the first and second modes, respectively, using single- and multiple-mode shunting. It is the purpose of this investigation to extend the passive piezoelectric shunt-damping technique to control structural vibration induced at higher acoustic excitation levels, and to examine the controllability and survivability of the bonded PZT transducers at these high levels. The shunting experiment was performed with the Thermal Acoustic Fatigue Apparatus (TAFA) at the NASA Langley Research Center using the same F-15 underbelly panel. The TAFA is a progressive wave tube facility. The panel was mounted in one wall of the TAFA test section using a specially designed mounting fixture such that the panel was subjected to grazing-incidence acoustic excitation. Five PZT transducers were used with two shunt circuits designed to control the first and second modes of the structure between 200 and 400 Hz. We first determined the values of the shunt inductance and resistance at an OASPL of 130 dB. These values were maintained while we gradually increased the OASPL from 130 to 154 dB in 6-dB steps. During each increment, the frequency response function between accelerometers on the panel and the acoustic excitation measured by microphones, before and after shunting, were recorded. Good response reduction was observed up to the 148dB level. The experiment was stopped at 154 dB due to wire breakage from vibration at a transducer wire joint. The PZT transducers, however, were still bonded well on the panel and survived at this high dB level. We also observed shifting of the frequency peaks toward lower frequency when the OASPL

  3. Effects of Different Heave Motion Components on Pilot Pitch Control Behavior

    Science.gov (United States)

    Zaal, Petrus M. T.; Zavala, Melinda A.

    2016-01-01

    The study described in this paper had two objectives. The first objective was to investigate if a different weighting of heave motion components decomposed at the center of gravity, allowing for a higher fidelity of individual components, would result in pilot manual pitch control behavior and performance closer to that observed with full aircraft motion. The second objective was to investigate if decomposing the heave components at the aircraft's instantaneous center of rotation rather than at the center of gravity could result in additional improvements in heave motion fidelity. Twenty-one general aviation pilots performed a pitch attitude control task in an experiment conducted on the Vertical Motion Simulator at NASA Ames under different hexapod motion conditions. The large motion capability of the Vertical Motion Simulator also allowed for a full aircraft motion condition, which served as a baseline. The controlled dynamics were of a transport category aircraft trimmed close to the stall point. When the ratio of center of gravity pitch heave to center of gravity heave increased in the hexapod motion conditions, pilot manual control behavior and performance became increasingly more similar to what is observed with full aircraft motion. Pilot visual and motion gains significantly increased, while the visual lead time constant decreased. The pilot visual and motion time delays remained approximately constant and decreased, respectively. The neuromuscular damping and frequency both decreased, with their values more similar to what is observed with real aircraft motion when there was an equal weighting of the heave of the center of gravity and heave due to rotations about the center of gravity. In terms of open- loop performance, the disturbance and target crossover frequency increased and decreased, respectively, and their corresponding phase margins remained constant and increased, respectively. The decomposition point of the heave components only had limited

  4. Make Your Own Solar Panel.

    Science.gov (United States)

    Suzuki, David

    1992-01-01

    Presents an activity in which students make a simulated solar panel to learn about the principles behind energy production using solar panels. Provides information about how solar panels function to produce energy. (MCO)

  5. Portable low-cost flat panel detectors for real-time digital radiography

    International Nuclear Information System (INIS)

    Iovea, Mihai; Neagu, Marian; Stefanescu, Bogdan; Mateiasi, Gabriela; Porosnicu, Ioana; Angheluta, Elena

    2015-01-01

    The X-ray inspection is one of the most common used non-destructive testing methods in industry applications, but for the portable X-ray digital solution are not so many accessible, low-cost and versatile detection devices. The efficiency of a non-destructive X-ray portable device is represented by the quality of digital images, by its low acquisition time combined with a high resolution, in condition of low noise and at an affordable cost. The paper presents two X-ray portable imaging systems developed by us, suitable also for aerospace NDT applications, which are also very versatile for being easily adapted for other fields that requires mobile solutions. The first device described in the paper represent a portable large-size (210 mm X 550 mm) and high-resolution (27/54 microns) flat panel detector based on linear translation of a X-Ray TDI detector, destined for various components/parts real-time transmission measurements. The second system it is also a flat panel detectors, with a size of 510 mm X 610 mm, with the detector size from 0.2 mm until 1.5 mm, which can operate by applying the dual-energy method, very useful for discriminating materials by evaluating their Atomic effective number. The high resolution and low-cost of this flat-panels widens their applicability by covering large requirements, from identifying unwanted materials within a structure until detection of very thin cracks in complex components.

  6. Portable low-cost flat panel detectors for real-time digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Iovea, Mihai; Neagu, Marian; Stefanescu, Bogdan; Mateiasi, Gabriela; Porosnicu, Ioana; Angheluta, Elena [Accent Pro 2000 S.R.L., Bucharest (Romania)

    2015-07-01

    The X-ray inspection is one of the most common used non-destructive testing methods in industry applications, but for the portable X-ray digital solution are not so many accessible, low-cost and versatile detection devices. The efficiency of a non-destructive X-ray portable device is represented by the quality of digital images, by its low acquisition time combined with a high resolution, in condition of low noise and at an affordable cost. The paper presents two X-ray portable imaging systems developed by us, suitable also for aerospace NDT applications, which are also very versatile for being easily adapted for other fields that requires mobile solutions. The first device described in the paper represent a portable large-size (210 mm X 550 mm) and high-resolution (27/54 microns) flat panel detector based on linear translation of a X-Ray TDI detector, destined for various components/parts real-time transmission measurements. The second system it is also a flat panel detectors, with a size of 510 mm X 610 mm, with the detector size from 0.2 mm until 1.5 mm, which can operate by applying the dual-energy method, very useful for discriminating materials by evaluating their Atomic effective number. The high resolution and low-cost of this flat-panels widens their applicability by covering large requirements, from identifying unwanted materials within a structure until detection of very thin cracks in complex components.

  7. Production facility for ATLAS new small wheel drift panels at JGU Mainz

    Energy Technology Data Exchange (ETDEWEB)

    Duedder, Andreas; Lin, Tai-Hua; Schott, Matthias [Johannes Gutenberg-Universitaet Mainz (Germany)

    2016-07-01

    The ATLAS Phase-I Upgrade in 2018 includes the replacement of the ATLAS Muon Small Wheel by the so-called New Small Wheel (NSW). Large-scale Micromegas detectors will serve as tracking detectors in the NSW. Parts of these detectors will be constructed at the Johannes Gutenberg University Mainz (JGU). In order to fulfill the requirements of the envisioned detector performance, a high precision detector construction is crucial. Especially the surface planarity of the produced detector panels has to better than 30 μm over an area of 2 m{sup 2}. Methods for the quality control of the raw material and the constructed parts have been developed and implemented. This talk gives an overview of the production facility at JGU Mainz which is used during the mass production of NSW components in coming years.

  8. Control, protection and measuring switchboards; Tableros de control, proteccion y medicion

    Energy Technology Data Exchange (ETDEWEB)

    Marron Pena, Gustavo A. [Luz y Fuerza del Centro, Mexico, D. F. (Mexico)

    1997-12-31

    Basically a switchboard is a cabinet or panel that contains equipment for protection of measuring and control high tension electric power components of high tension, such as: transmission power lines, power station generators or power plants, power transformers, and distribution feeders. In this paper the importance of control, Protection and Measuring Switchboards is discussed and the power installations of the national electric system is analyzed and finally, a description is made of the quality system applied in the manufacture of switchboards at Luz y Fuerza del Centro in accordance with ISO-9000 and NMX-CC Standards [Espanol] Un tablero basicamente es un gabinete o panel que contiene equipos que sirven para proteger, medir y controlar componentes electricos de potencia en alta tension, como son: lineas de transmision, generadores de centrales o plantas electricas, transformadores de potencia y alimentadores de distribucion. En este documento se analiza la importancia de los tableros de control, la proteccion y medicion en las instalaciones de potencia del sistema electrico nacional y por ultimo se describe el sistema de calidad aplicado en la fabricacion de tableros de Luz y Fuerza del Centro de acuerdo con las normas ISO-9000 y NMX-CC

  9. Gravity sag of sandwich panel assemblies as applied to precision cathode strip chamber structural design

    International Nuclear Information System (INIS)

    Horvath, J.

    1993-01-01

    The relationship between gravity sag of a precision cathode strip chamber and its sandwich panel structural design is explored parametrically. An algorithm for estimating the dominant component of gravity sag is defined. Graphs of normalized gravity sag as a function of gap frame width and material, sandwich core edge filler width and material, panel skin thickness, gap height, and support location are calculated using the gravity sag algorithm. The structural importance of the sandwich-to-sandwich ''gap frame'' connection is explained

  10. Artabilitation ICMC Panel paper Denmark 2007:Non-Formal Rehabilitation via Immersiveinteractive Music Environments

    DEFF Research Database (Denmark)

    Brooks, Tony; Petersson, Eva; Eaglestone, Barry

    2007-01-01

    This paper brings together perspectives of the ICMC 2007 ArtAbilitation Panel on non-formal rehabilitation via immersive interactive music environments. Issues covered are sound therapy, musical topologies, brainwave control and research methodology.......This paper brings together perspectives of the ICMC 2007 ArtAbilitation Panel on non-formal rehabilitation via immersive interactive music environments. Issues covered are sound therapy, musical topologies, brainwave control and research methodology....

  11. Solar panel parallel mounting configuration

    Science.gov (United States)

    Mutschler, Jr., Edward Charles (Inventor)

    1998-01-01

    A spacecraft includes a plurality of solar panels interconnected with a power coupler and an electrically operated device to provide power to the device when the solar cells are insolated. The solar panels are subject to bending distortion when entering or leaving eclipse. Spacecraft attitude disturbances are reduced by mounting each of the solar panels to an elongated boom made from a material with a low coefficient of thermal expansion, so that the bending of one panel is not communicated to the next. The boom may be insulated to reduce its bending during changes in insolation. A particularly advantageous embodiment mounts each panel to the boom with a single mounting, which may be a hinge. The single mounting prevents transfer of bending moments from the panel to the boom.

  12. Seismic hazard analysis. Review panel, ground motion panel, and feedback results

    International Nuclear Information System (INIS)

    Bernreuter, D.L.

    1981-10-01

    The Site Specific Spectra Project (SSSP) was a multi-year study funded by the U.S. Nuclear Regulatory Commission to provide estimates of the seismic hazards at a number of nuclear power plant sites in the Eastern U.S. A key element of our approach was the Peer Review Panel, which we formed in order to ensure that our use of expert opinion was reasonable. We discuss the Peer Review Panel results and provide the complete text of each member's report. In order to improve the ground motion model, an Eastern U.S. Ground Motion Model Panel was formed. In Section 4 we tabulate the responses from the panel members to our feedback questionnaire and discuss the implications of changes introduced by them. We conclude that the net difference in seismic hazard values from those presented in Volume 4 is small and does not warrant a reanalysis. (author)

  13. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph

    2017-07-11

    A photovoltaic panel mounting clip comprising a base, central indexing tabs, flanges, lateral indexing tabs, and vertical indexing tabs. The mounting clip removably attaches one or more panels to a beam or the like structure, both mechanically and electrically. It provides secure locking of the panels in all directions, while providing guidance in all directions for accurate installation of the panels to the beam or the like structure.

  14. CubeSat Form Factor Thermal Control Louvers

    Science.gov (United States)

    Evans, Allison L. (Inventor)

    2018-01-01

    Thermal control louvers for CubeSats or small spacecraft may include a plurality of springs attached to a back panel of the thermal control louvers. The thermal control louvers may also include a front panel, which includes at least two end panels interlocked with one or more middle panels. The front panel may secure the springs, shafts, and flaps to the back panel.

  15. The procurement and testing of the stainless steel in-vessel panels of the Wendelstein 7-X Stellarator

    International Nuclear Information System (INIS)

    Peacock, A.; Girlinger, A.; Vorkoeper, A.; Boscary, J.; Greuner, H.; Hurd, F.; Mendelevitch, B.; Pirsch, H.; Stadler, R.; Zangl, G.

    2011-01-01

    320 In-vessel water cooled stainless steel panels, poloidal closure plates and pumping gap panels, covering an area of approximately 100 m 2 , are used in Wendelstein7-X to protect the plasma vessel. The panels are manufactured at Deggendorf, Germany by MAN Diesel and Turbo SE. The panels consist of a laser welded sandwich of stainless steel plates together with a labyrinth of cooling channels and have a complicated geometry to fit the plasma vessel of Wendelstein 7-X. The hydraulic and mechanical stability requirements whilst maintaining the tight tolerances for the shape of the components are very demanding. The panels are designed to operate at up to an average heat load of 100 kW/m 2 and a maximum heat load of 200 kW/m 2 with a water velocity of approximately 2 m s -1 . High heat flux testing of an un-cooled panel at a time averaged load of 200 kW/m 2 for 10 s were successfully performed to support the start up phase of Wendelstein 7-X operation. Extensive testing both during manufacture and after delivery to IPP-Garching demonstrates the suitability of the delivered panels for their purpose.

  16. Passive acoustic radiation control for a vibrating panel with piezoelectric shunt damping circuit using particle swarm optimization algorithm

    International Nuclear Information System (INIS)

    Jeon, Jin Young

    2009-01-01

    This paper presents a new acoustic radiation optimization method for a vibrating panel-like structure with a passive piezoelectric shunt damping system in order to minimize well-radiating modes generated from the panel. The optimization method is based on an idea of using the p-version finite element method(p-version FEM), the boundary element method(BEM), and the particle swarm optimization algorithm(PSOA). Optimum embossment design for the vibrating panel using the PSOA is first investigated in order to minimize noise radiation over a frequency range of interest. The optimum embossment design works as a kind of stiffener so that well-radiating natural modes are shifted up with some degrees. The optimized panel, however, may still require additional damping for attenuating the peak acoustic amplitudes. A passive shunt damping system is thus employed to additionally damp the well-radiating modes from the optimized panel. To numerically evaluate the acoustic multiple-mode damping capability by a shunt damping system, the integrated p-version FEM/BEM for the panel with the shunt damping system is modeled and developed by MATLAB. Using the PSOA, the optimization technique for the optimal multiple-mode shunt damper is investigated in order to achieve the optimum damping performance for the well-radiating modes simultaneously. Also, the acoustic damping performance of the shunt damping circuit in the acoustic environment is demonstrated numerically and experimentally with respect to the realistically sized panel. The simulated result shows a good agreement with that of the experimental result

  17. Development of Dynamic Loudspeakers Modified as Incident Pressure Sources for Noise Reductiuon in a Double Panel Structure

    NARCIS (Netherlands)

    Ho, J.H.; Berkhoff, A.P.

    2013-01-01

    This paper presents a modified loudspeaker source for decentralized feedback cavity control in a double panel structure to reduce the noise transmission. The double panel structure con-sists of two panels with air in between and offers the advantages of low weight, low sound transmission at high

  18. Development of dynamic loudspeakers modified as incident pressure sources for noise reduction in a double panel structure

    NARCIS (Netherlands)

    Ho, J.; Berkhoff, Arthur P.; Crocker, Malcolm J.; Pawelczyk, Marek; Paosawatyanyong, Boonchoat

    2013-01-01

    This paper presents a modified loudspeaker source for decentralized feedback cavity control in a double panel structure to reduce the noise transmission. The double panel structure con-sists of two panels with air in between and offers the advantages of low weight, low sound transmission at high

  19. Out-of-autoclave manufacturing of a stiffened thermoplastic carbon fibre PEEK panel

    Science.gov (United States)

    Flanagan, M.; Goggins, J.; Doyle, A.; Weafer, B.; Ward, M.; Bizeul, M.; Canavan, R.; O'Bradaigh, C.; Doyle, K.; Harrison, N.

    2017-10-01

    Out-of-Autoclave manufacturing methods, specifically Automated Tape Placement (ATP) and induction welding, used in the fabrication of a stiffened thermoplastic demonstrator panel, are presented in this study. The demonstrator panel consists of two stiffeners induction welded to a flat skin, to form a typical load bearing aerospace sub-component. The skin of the panel is manufactured from uni-directional Carbon Fibre (CF) Polyetheretherkeytone (PEEK) using laser assisted Automated Tape Placement (ATP) and the stiffeners are press formed from woven CF-PEEK. The stiffeners are fusion bonded to the skin using a continuous induction welding process. A susceptor material is used at the interface to ensure the required heating is concentrated at the weldline. Microscopy was used to examine the manufactured coupons for defects. Destructive testing was carried out to evaluate the strength of the overall assembly. The work shows that assemblies manufactured using continuous induction welding and ATP are suitable for load bearing aerospace applications.

  20. Flight service evaluation of Kevlar-49 epoxy composite panels in wide-bodied commercial transport aircraft

    Science.gov (United States)

    Stone, R. H.

    1984-01-01

    Kevlar-49 fairing panels, installed as flight service components on three L-1011s, were inspected after 10 years of service. There are six Kevlar-49 panels on each aircraft: a left-hand and right-hand set of a wing-body sandwich fairing; a solid laminate under-wing fillet panel; and a 422 K (300 F) service aft engine fairing. The three L-1011s include one each in service with Eastern, Air Canada, and TWA. The fairings have accumulated a total of 79,568 hours, with one ship set having nearly 28,000 hours service. The inspections were conducted at the airlines' major maintenance bases with the participation of Lockheed Engineering. The Kevlar-49 components were found to be performing satisfactorily in service with no major problems, or any condition requiring corrective action. The only defects noted were minor impact damage, a few minor disbonds and a minor degree of fastener hole fraying and elongation. These are for the most part comparable to damage noted on fiberglass fairings. The service history obtained in this program indicates that Kevlar-49 epoxy composite materials have satisfactory service characteristics for use in aircraft secondary structure.

  1. 1480 W Plts Solar Power Plant Architecture With Solar Tracker For Controlling Microcontroller-Based Solar Panel In Tigaraja Village Sub-District Of Tigadolok Regency Of Simalungun

    Directory of Open Access Journals (Sweden)

    Robert Samosir

    2017-12-01

    Full Text Available Electrical energy has become a basic need for human being. In some remote areas however electricity is unreachable and poses a taboo subject and cannot be enjoyed by local people such as in Tigaraja Village Sub-District of Tigadolok Regency of Simalungun. The sun is a renewable energy that it is beneficial for power plant use. With PLTS solar energy can be changed into the sun through the solar panel. Battery Charge Regulator BCR operates stabilizing voltage from solar panel to battery. The battery will save electrical power to be distributed for household consumption. Since battery power has direct current however Inverter operates changing its direct current into alternating current. To optimize absorption of solar energy a servo motor is used to make solar panel moving by following the suns path. Arduino Uno as direct control of solar panel using solar sensor gives current for servo motor. Then the servo motor can move in reverse and forward. Therefore Household goods like water pumps lamps and televisions have been worked when people come home from their work.

  2. Use of statistical process control in the production of blood components

    DEFF Research Database (Denmark)

    Magnussen, K.; Quere, S.; Winkel, P.

    2008-01-01

    occasional component manufacturing staff to an experienced regular manufacturing staff. Production of blood products is a semi-automated process in which the manual steps may be difficult to control. This study was performed in an ongoing effort to improve the control and optimize the quality of the blood...

  3. Panel Session

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege

    2004-01-01

    In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach.......In this panel session, four researchers will discuss the role of a theoretical foundation, in particular AT, in the design of information technology based artefacts. The general discussion will take of from a specific examination of the ActAD approach....

  4. Sampling methods to the statistical control of the production of blood components.

    Science.gov (United States)

    Pereira, Paulo; Seghatchian, Jerard; Caldeira, Beatriz; Santos, Paula; Castro, Rosa; Fernandes, Teresa; Xavier, Sandra; de Sousa, Gracinda; de Almeida E Sousa, João Paulo

    2017-12-01

    The control of blood components specifications is a requirement generalized in Europe by the European Commission Directives and in the US by the AABB standards. The use of a statistical process control methodology is recommended in the related literature, including the EDQM guideline. The control reliability is dependent of the sampling. However, a correct sampling methodology seems not to be systematically applied. Commonly, the sampling is intended to comply uniquely with the 1% specification to the produced blood components. Nevertheless, on a purely statistical viewpoint, this model could be argued not to be related to a consistent sampling technique. This could be a severe limitation to detect abnormal patterns and to assure that the production has a non-significant probability of producing nonconforming components. This article discusses what is happening in blood establishments. Three statistical methodologies are proposed: simple random sampling, sampling based on the proportion of a finite population, and sampling based on the inspection level. The empirical results demonstrate that these models are practicable in blood establishments contributing to the robustness of sampling and related statistical process control decisions for the purpose they are suggested for. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Computer control of the high-voltage power supply for the DIII-D Electron Cyclotron Heating system

    International Nuclear Information System (INIS)

    Clow, D.D.; Kellman, D.H.

    1991-10-01

    The D3-D Electron Cyclotron Heating (ECH) high voltage power supply is controlled by a computer. Operational control is input via keyboard and mouse, and computer/power supply interface is accomplished with a Computer Assisted Monitoring and Control (CAMAC) system. User-friendly tools allow the design and layout of simulated control panels on the computer screen. Panel controls and indicators can be changed, added or deleted, and simple editing of user-specific processes can quickly modify control and fault logic. Databases can be defined, and control panel functions are easily referred to various data channels. User-specific processes are written and linked using Fortran, to manage control and data acquisition through CAMAC. The resulting control system has significant advantages over the hardware it emulates: changes in logic, layout, and function are quickly and easily incorporated; data storage, retrieval, and processing are flexible and simply accomplished, physical components subject to wear and degradation are minimized. In addition, the system can be expanded to multiplex control of several power supplied, each with its own database, through a single computer and console. 5 refs., 4 figs., 1 tab

  6. 78 FR 41937 - Joint Meeting of the Gastroenterology-Urology Panel and the Radiological Devices Panel of the...

    Science.gov (United States)

    2013-07-12

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0816] Joint Meeting of the Gastroenterology-Urology Panel and the Radiological Devices Panel of the Medical...: Gastroenterology-Urology Panel and Radiological Devices Panel of the Medical Devices Advisory Committee. General...

  7. Front panel human interface for FASTBUS

    International Nuclear Information System (INIS)

    Gustavson, D.B.; Holmes, T.L.; Paffrath, L.; Steffani, J.P.

    1980-01-01

    A human interface based on the Snoop diagnostic module has been designed to facilitate checkout of FASTBUS devices, diagnosis of system faults, and monitoring of system performance. This system, which is a generalization of the usual computer front panel or control console, includes logic analyzer functions, display and manual-control access to other modules, a microprocessor which allows the user to create and execute diagnostic programs and store them on a minifloppy disk, and a diagnostic network which allows remote console operation and coordination of information from multiple segments' Snoops

  8. Sound transmission reduction with intelligent panel systems

    Science.gov (United States)

    Fuller, Chris R.; Clark, Robert L.

    1992-01-01

    Experimental and theoretical investigations are performed of the use of intelligent panel systems to control the sound transmission and radiation. An intelligent structure is defined as a structural system with integrated actuators and sensors under the guidance of an adaptive, learning type controller. The system configuration is based on the Active Structural Acoustic Control (ASAC) concept where control inputs are applied directly to the structure to minimize an error quantity related to the radiated sound field. In this case multiple piezoelectric elements are employed as sensors. The importance of optimal shape and location is demonstrated to be of the same order of influence as increasing the number of channels of control.

  9. Investigation on the Acoustic Absorption of Flexible Micro-Perforated Panel with Ultra-Micro Perforations

    Science.gov (United States)

    Li, Guoxin; Tang, Xiaoning; Zhang, Xiaoxiao; Qian, Y. J.; Kong, Deyi

    2017-11-01

    Flexible micro-perforated panel has unique advantages in noise reduction due to its good flexibility compared with traditional rigid micro-perforated panel. In this paper, flexible micro-perforated panel was prepared by computer numerical control (CNC) milling machine. Three kinds of plastics including polyvinylchloride (PVC), polyethylene terephthalate (PET), and polyimide (PI) were taken as the matrix materials to prepare flexible micro-perforated panel. It has been found that flexible micro-perforated panel made of PET possessing good porosity and proper density, elastic modulus and poisson ratio exhibited the best acoustic absorption properties. The effects of various structural parameters including perforation diameter, perforation ratio, thickness and air gap have also been investigated, which would be helpful to the optimization of acoustic absorption properties.

  10. Neutron Characterization of Additively Manufactured Components. Workshop Report

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Thomas R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Payzant, E. Andrew [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Babu, Sudarsanam Suresh [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-09-01

    Additive manufacturing (AM) is a collection of promising manufacturing methods that industry is beginning to explore and adopt. Macroscopically complicated and near net shape components are being built using AM, but how the material behaves in service is a big question for industry. Consequently, AM components/materials need further research into exactly what is made and how it will behave in service. This one and a half day workshop included a series of invited presentations from academia, industry and national laboratories (see Appendix A for the workshop agenda and list of talks). The workshop was welcomed by Alan Tennant, Chief Scientist, Neutron Sciences Directorate, ORNL, and opened remotely by Rob Ivestor, Deputy Director, Advanced Manufacturing Office-DOE, who declared AM adoptees as titans who will be able to create customized 3-D structures with 1 million to 1 billion micro welds with locally tailored microstructures. Further he stated that characterization with neutrons is key to be able to bring critical insight/information into the AM process/property/behavior relationship. Subsequently, the presentations spanned a slice of the current state of the art AM techniques and many of the most relevant characterization techniques using neutrons. After the talks, a panel discussion was held; workshop participants (see Appendix B for a list of attendees) providing questions and the panel answers. The main purpose of the panel discussion was to build consensus regarding the critical research needs in AM that can be addressed with neutrons. These needs were placed into three categories: modes of access for neutrons, new capabilities needed, new AM material issues and neutrons. Recommendations from the workshop were determined based on the panel discussion.

  11. Peer review panel summary report for technical determination of mixed waste incineration off-gas systems for Rocky Flats

    International Nuclear Information System (INIS)

    1992-01-01

    A Peer Review Panel was convened on September 15-17, 1992 in Boulder, Co. The members of this panel included representatives from DOE, EPA, and DOE contractors along with invited experts in the fields of air pollution control and waste incineration. The primary purpose of this review panel was to make a technical determination of a hold, test and release off gas capture system should be implemented in the proposed RF Pland mixed waste incineration system; or if a state of the art continuous air pollution control and monitoring system should be utilized as the sole off-gas control system. All of the evaluations by the panel were based upon the use of the fluidized bed unit proposed by Rocky Flats and cannot be generalized to other systems

  12. The development of a closed-loop flight controller with panel method integration for gust alleviation using biomimetic feathers on aircraft wings

    Science.gov (United States)

    Blower, Christopher J.; Lee, Woody; Wickenheiser, Adam M.

    2012-04-01

    This paper presents the development of a biomimetic closed-loop flight controller that integrates gust alleviation and flight control into a single distributed system. Modern flight controllers predominantly rely on and respond to perturbations in the global states, resulting in rotation or displacement of the entire aircraft prior to the response. This bio-inspired gust alleviation system (GAS) employs active deflection of electromechanical feathers that react to changes in the airflow, i.e. the local states. The GAS design is a skeletal wing structure with a network of featherlike panels installed on the wing's surfaces, creating the airfoil profile and replacing the trailing-edge flaps. In this study, a dynamic model of the GAS-integrated wing is simulated to compute gust-induced disturbances. The system implements continuous adjustment to flap orientation to perform corrective responses to inbound gusts. MATLAB simulations, using a closed-loop LQR integrated with a 2D adaptive panel method, allow analysis of the morphing structure's aerodynamic data. Non-linear and linear dynamic models of the GAS are compared to a traditional single control surface baseline wing. The feedback loops synthesized rely on inertial changes in the global states; however, variations in number and location of feather actuation are compared. The bio-inspired system's distributed control effort allows the flight controller to interchange between the single and dual trailing edge flap profiles, thereby offering an improved efficiency to gust response in comparison to the traditional wing configuration. The introduction of aero-braking during continuous gusting flows offers a 25% reduction in x-velocity deviation; other flight parameters can be reduced in magnitude and deviation through control weighting optimization. Consequently, the GAS demonstrates enhancements to maneuverability and stability in turbulent intensive environments.

  13. SPS/LEP beam transfer equipment control using industrial automation components

    International Nuclear Information System (INIS)

    Aimar, A.; Berard, G.; Bretin, J.L.; Carlier, E.; Dieperink, J.H.; Laffin, M.; Mertens, V.; Verhagen, H.

    1992-01-01

    Several control systems for SPS and LEP beam transfer equipment have to be commissioned in the near future. Tools for fast software development, easy maintenance and modifications, compliance with industrial standards, and independence of specific suppliers are considered to be essential. A large fraction of the systems can be realized using off-the-shelf industrial automation components like industrial I/O systems, programmable logic controllers, or diskless PCs. Specific electronics built up in G-64 can be integrated. Diskless systems running UNIX and X Windows are foreseen as process controllers and local access media. (author)

  14. Quality Control Activities Related to Mechanical Maintenance of Safety Related Components at Krsko NPP

    International Nuclear Information System (INIS)

    Djakovic, D.

    2016-01-01

    For successful, safe and reliable operation of nuclear power plant, maintenance processes have to be systematically controlled and procedures for quality control of maintenance activities shall be established. This is requested by the quality assurance program, which shall provide control over activities affecting the quality of structures, systems, and components, considering their importance to safety. As a part of Quality and Nuclear Oversight Division (QNOD; SKV), the Quality Control Department (QC) provides quality control activities, which are deeply involved in maintenance processes at Krsko NPP, both on safety related and non-safety related (non-nuclear safety) components. QC activities on safety related components have to fulfil all requirements, which will enable the components to perform their intended safety functions. This paper describes quality control activities related to mechanical maintenance of safety related components at Krsko NPP and significant role of the Krsko plant QC Department in three particular maintenance cases connected with safety related components. In these three specific cases, the QC has confirmed its importance in compliance with quality assurance program and presented its significant added value in providing safe and reliable operation of the plant. The first maintenance activity was installation of nozzle check valves in the scope of a modification for improving regulation of spent fuel pit pumps. The QC Department performed receipt inspection of the valves. Using non-destructive examination methods and X-ray spectrometry, it was found out that the valve diffuser was made of improper material, which could cause progressive corrosion of the valve diffuser in borated water and consequently a loss of safety function of the valves followed by long-term consequences. The second one was the receipt inspection of containment ventilation fan coolers. The coolers were claimed and sent back to the supplier because the QC Department

  15. Components of self-esteem in affective patients and non-psychiatric controls.

    Science.gov (United States)

    Serretti, Alessandro; Olgiati, Paolo; Colombo, Cristina

    2005-09-01

    Decrease in self-esteem (SE) is found in all mood disorders during inter-episode phases. This trait was associated with relapse and suicidality but its genetic basis is still undefined, probably because SE has multiple components. The aim of the current study was to ascertain which of those components were altered in a sample of affective patients. Three hundred and thirty-one outpatients with bipolar (N=199) and major depressive MD (N=132) disorders in remission for at least three months and one hundred controls completed the Rosenberg Self-esteem Scale (RSE; [Rosenberg, M., 1965. The measurement of self-esteem, Society and the Adolescent Self-Image. Princeton University Press, pp.16-36]). Principal component analysis was performed to identify RSE factor structure. Extracted factors were compared across case and control groups in the whole sample (N=431) and in a sub-sample (N=301) with low self-esteem (RSE <20). PCA yielded a two-factor solution with self-confidence (SC) and self-deprecation (SD) that was largely consistent with the existing literature. Such factors were both associated with lower scores in affective patients than controls (SC: F=52, p<0.01; SD: F=43, p<0.01). However in the low RSE group only self-confidence was found to be decreased in subjects with mood disorders (SC: F=13.8, p<0.01; SD: F=0.05, p=0.9). These findings suggest that self-esteem deficit in affective disorders might involve specific components. Implications for research and clinical practice are discussed.

  16. Use of Internet panels to conduct surveys.

    Science.gov (United States)

    Hays, Ron D; Liu, Honghu; Kapteyn, Arie

    2015-09-01

    The use of Internet panels to collect survey data is increasing because it is cost-effective, enables access to large and diverse samples quickly, takes less time than traditional methods to obtain data for analysis, and the standardization of the data collection process makes studies easy to replicate. A variety of probability-based panels have been created, including Telepanel/CentERpanel, Knowledge Networks (now GFK KnowledgePanel), the American Life Panel, the Longitudinal Internet Studies for the Social Sciences panel, and the Understanding America Study panel. Despite the advantage of having a known denominator (sampling frame), the probability-based Internet panels often have low recruitment participation rates, and some have argued that there is little practical difference between opting out of a probability sample and opting into a nonprobability (convenience) Internet panel. This article provides an overview of both probability-based and convenience panels, discussing potential benefits and cautions for each method, and summarizing the approaches used to weight panel respondents in order to better represent the underlying population. Challenges of using Internet panel data are discussed, including false answers, careless responses, giving the same answer repeatedly, getting multiple surveys from the same respondent, and panelists being members of multiple panels. More is to be learned about Internet panels generally and about Web-based data collection, as well as how to evaluate data collected using mobile devices and social-media platforms.

  17. Centers for Disease Control review panel's recommendations on health effects and epidemiological studies of operations at the Savannah River Plant, Aiken, South Carolina. Public comment and meeting report

    International Nuclear Information System (INIS)

    1985-05-01

    Based on the request of the US Department of Energy, the Centers for Disease Control of the US Department of Health and Human Services organized a panel to review the feasibility and usefulness of conducting further epidemiologic studies of delayed health effects around the Department of Energy's Savannah River Plant. The review and recommendations of the panel were documented in a report entitled Epidemiologic Projects Considered Possible to Undertake in Populations Around the Savannah River Plant. On November 30, 1984, the Department of Energy announced in the Federal Register (49 FR 47095) the conduct of a public meeting and a 30-day public comment period between December 1 and December 30, 1984, on the recommendations of the review panel. Based on the requests of individuals and representatives of organizations attending the December 18, 1984, public meetings, the Department of Energy subsequently announced in the Federal Register on December 31, 1984 (49 FR 50767) an extension of the public comment period to January 31, 1985. This report documents the public meeting and comment process, and provides responses to the public comments that were submitted during this process. In addition, this report contains the Department of Energy's position based on the recommendations of the Centers for Disease Control review panel and the public comments. 23 refs., 16 tabs

  18. Aircraft panel with sensorless active sound power reduction capabilities through virtual mechanical impedances

    Science.gov (United States)

    Boulandet, R.; Michau, M.; Micheau, P.; Berry, A.

    2016-01-01

    This paper deals with an active structural acoustic control approach to reduce the transmission of tonal noise in aircraft cabins. The focus is on the practical implementation of the virtual mechanical impedances method by using sensoriactuators instead of conventional control units composed of separate sensors and actuators. The experimental setup includes two sensoriactuators developed from the electrodynamic inertial exciter and distributed over an aircraft trim panel which is subject to a time-harmonic diffuse sound field. The target mechanical impedances are first defined by solving a linear optimization problem from sound power measurements before being applied to the test panel using a complex envelope controller. Measured data are compared to results obtained with sensor-actuator pairs consisting of an accelerometer and an inertial exciter, particularly as regards sound power reduction. It is shown that the two types of control unit provide similar performance, and that here virtual impedance control stands apart from conventional active damping. In particular, it is clear from this study that extra vibrational energy must be provided by the actuators for optimal sound power reduction, mainly due to the high structural damping in the aircraft trim panel. Concluding remarks on the benefits of using these electrodynamic sensoriactuators to control tonal disturbances are also provided.

  19. 1994 Panel 1 Utilization Plan

    International Nuclear Information System (INIS)

    1994-01-01

    The Waste Isolation Pilot Plant (WIPP) is intended to receive, handle, and permanently dispose of transuranic (TRU) waste. To fulfill this mission, the U.S. Department of Energy (DOE) constructed a full-scale facility to demonstrate both technical and operational principles of the permanent isolation of TRU waste. The WIPP consists of surface and underground facilities. Panel 1 is situated in the underground facility horizon which is located approximately 2,150 feet below the surface in the predominantly halite Salado Formation. The Panel 1 Utilization Plan provides a strategy for the optimum use of Panel 1 which is consistent with the priorities established by the DOE to accomplish the WIPP mission. These priorities, which include maintaining personnel safety, conducting performance assessment, and continued operational enhancements, are the guiding premise for the decisions on the planned usage of the WIPP underground facility. The continuation of ongoing investigations along with the planned testing and training to be carried out in Panel 1 will enhance the current knowledge and understanding of the operational and geotechnical aspects of the panel configuration. This enhancement will ultimately lead to safer, more efficient, and more cost-effective methods of operation. Excavation of the waste storage area began in May 1986 with the mining of entries to Panel 1. The original design for the waste storage rooms at the WIPP provided a limited period of time during which to mine the openings and to emplace waste. Each panel, consisting of seven storage rooms, was scheduled to be mined and filled in less than 5 years. Panel 1 was developed to receive waste for a demonstration phase that was scheduled to start in October 1988. The demonstration phase was deferred, and the experimental test program was modified to use contact-handled (CH) transuranic waste in bin-scale tests, planned for Room 1, Panel 1

  20. The procurement and testing of the stainless steel in-vessel panels of the Wendelstein 7-X Stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Peacock, A., E-mail: alan.peacock@ipp.mpg.de [European Commission c/o Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Girlinger, A. [MAN Diesel and Turbo SE D-94469 Deggendorf (Germany); Vorkoeper, A. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 17491 Greifswald (Germany); Boscary, J.; Greuner, H. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Hurd, F. [European Commission c/o Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany); Mendelevitch, B.; Pirsch, H.; Stadler, R.; Zangl, G. [Max-Planck-Institut fuer Plasmaphysik, EURATOM Association, 85748 Garching (Germany)

    2011-10-15

    320 In-vessel water cooled stainless steel panels, poloidal closure plates and pumping gap panels, covering an area of approximately 100 m{sup 2}, are used in Wendelstein7-X to protect the plasma vessel. The panels are manufactured at Deggendorf, Germany by MAN Diesel and Turbo SE. The panels consist of a laser welded sandwich of stainless steel plates together with a labyrinth of cooling channels and have a complicated geometry to fit the plasma vessel of Wendelstein 7-X. The hydraulic and mechanical stability requirements whilst maintaining the tight tolerances for the shape of the components are very demanding. The panels are designed to operate at up to an average heat load of 100 kW/m{sup 2} and a maximum heat load of 200 kW/m{sup 2} with a water velocity of approximately 2 m s{sup -1}. High heat flux testing of an un-cooled panel at a time averaged load of 200 kW/m{sup 2} for 10 s were successfully performed to support the start up phase of Wendelstein 7-X operation. Extensive testing both during manufacture and after delivery to IPP-Garching demonstrates the suitability of the delivered panels for their purpose.

  1. Practical Efficiency of Photovoltaic Panel Used for Solar Vehicles

    Science.gov (United States)

    Koyuncu, T.

    2017-08-01

    In this experimental investigation, practical efficiency of semi-flexible monocrystalline silicon solar panel used for a solar powered car called “Firat Force” and a solar powered minibus called “Commagene” was determined. Firat Force has 6 solar PV modules, a maintenance free long life gel battery pack, a regenerative brushless DC electric motor and Commagene has 12 solar PV modules, a maintenance free long life gel battery pack, a regenerative brushless DC electric motor. In addition, both solar vehicles have MPPT (Maximum power point tracker), ECU (Electronic control unit), differential, instrument panel, steering system, brake system, brake and gas pedals, mechanical equipments, chassis and frame. These two solar vehicles were used for people transportation in Adiyaman city, Turkey, during one year (June 2010-May 2011) of test. As a result, the practical efficiency of semi-flexible monocrystalline silicon solar panel used for Firat Force and Commagene was determined as 13 % in despite of efficiency value of 18% (at 1000 W/m2 and 25 °C ) given by the producer company. Besides, the total efficiency (from PV panels to vehicle wheel) of the system was also defined as 9%.

  2. Data quality in probability-based online panels: Nonresponse, attrition, and panel conditioning

    NARCIS (Netherlands)

    Struminskaya, B.; Methodology and statistics for the behavioural and social sciences

    2014-01-01

    Online panels – surveys administered over the Internet in which persons are asked to complete surveys regularly – offer cost reductions compared to surveys that use more traditional modes of data collection (face-to-face, telephone, and mail). However, some characteristics of online panels may cause

  3. Blast response of curved carbon/epoxy composite panels: Experimental study and finite-element analysis

    International Nuclear Information System (INIS)

    Phadnis, V A; Roy, A; Silberschmidt, V V; Kumar, P; Shukla, A

    2013-01-01

    Experimental and numerical studies were conducted to understand the effect of plate curvature on blast response of carbon/epoxy composite panels. A shock-tube system was utilized to impart controlled shock loading to quasi-isotropic composite panels with differing range of radii of curvatures. A 3D Digital Image Correlation (DIC) technique coupled with high-speed photography was used to obtain out-of-plane deflection and velocity, as well as in-plane strain on the back face of the panels. Macroscopic post-mortem analysis was performed to compare yielding and deformation in these panels. A dynamic computational simulation that integrates fluid-structure interaction was conducted to evaluate the panel response in general purpose finite-element software ABAQUS/Explicit. The obtained numerical results were compared to the experimental data and showed a good correlation

  4. Flexural Behaviour of Precast Aerated Concrete Panel (PACP with Added Fibrous Material: An Overview

    Directory of Open Access Journals (Sweden)

    Abdul Rahim Noor Hazlin

    2017-01-01

    Full Text Available The usage of precast aerated concrete panel as an IBS system has become the main alternative to conventional construction system. The usage of this panel system contributes to a sustainable and environmental friendly construction. This paper presents an overview of the precast aerated concrete panel with added fibrous material (PACP. PACP is fabricated from aerated foamed concrete with added Polypropylene fibers (PP. The influence of PP on the mechanical properties of PACP are studied and reviewed from previous research. The structural behaviour of precast concrete panel subjected to flexure load is also reviewed. It is found that PP has significant affects on the concrete mixture’s compressive stregth, tensile strength and flexural strength. It is also found that PP manage to control the crack propagation in the concrete panel.

  5. TWRS vadose zone contamination issue expert panel status report

    International Nuclear Information System (INIS)

    Shafer, D.S.

    1997-01-01

    -imposed. The institutional problems they encountered include having both Tank Waste Remediation System (TWRS), the parent organization of the Vadose Zone Characterization Program and Environmental Restoration (ER), each under different regulatory controls and different organizational units, seeking to defend the status quo and discount many of the Panel's conclusions and recommendations. The results presented in the SX Tank Farm Report, especially the visualizations, have created concern in the public sector, both on a local, personal level and on a national political level

  6. Solar panel truss mounting systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2016-06-28

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  7. Solar panel truss mounting systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2018-01-30

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  8. Solar panel truss mounting systems and methods

    Science.gov (United States)

    Al-Haddad, Tristan Farris; Cavieres, Andres; Gentry, Russell; Goodman, Joseph; Nolan, Wade; Pitelka, Taylor; Rahimzadeh, Keyan; Brooks, Bradley; Lohr, Joshua; Crooks, Ryan; Porges, Jamie; Rubin, Daniel

    2015-10-20

    An exemplary embodiment of the present invention provides a solar panel truss mounting system comprising a base and a truss assembly coupled to the base. The truss assembly comprises a first panel rail mount, second panel rail mount parallel to the first panel rail mount, base rail mount parallel to the first and second panel rail mounts, and a plurality of support members. A first portion of the plurality of support members extends between the first and second panel rail mounts. A second portion of the plurality of support members extends between the first panel rail mount and the base rail mount. A third portion of the plurality of support members extends between the second panel rail mount and the base rail mount. The system can further comprise a plurality of connectors for coupling a plurality of photovoltaic solar panels to the truss assembly.

  9. Photovoltaic solar panels of crystalline silicon: characterization and separation

    International Nuclear Information System (INIS)

    Diasa, P.R.; Benevita, M.G.; Veita, H.M.

    2014-01-01

    The search for alternative power generation sources has been intensified in recent years. One of these alternatives is solar energy, since it is a virtually inexhaustible source and generates relatively small environmental impact compared to other traditional generation sources. The collection of solar energy and its conversion into thermal or electrical energy is only possible through the use of photovoltaic panels. These panels have a limited lifespan and will eventually be replaced by new ones. Thus, in the near future, large amounts of solar modules can be discarded as waste electronics. In order to retrieve important raw materials, reducing production costs and environmental impacts, recycling such materials is important. In this paper, photovoltaic module components were characterized through visual inspection, FRX, EDS and AAS. The glass was identified as ordinary glass (soda-lime glass), which allows reuse without any previous treatment and the metallic filaments were identified as tin- lead coated copper. (author)

  10. Prevalence of bloodstream pathogens is higher in neonatal encephalopathy cases vs. controls using a novel panel of real-time PCR assays.

    Science.gov (United States)

    Tann, Cally J; Nkurunziza, Peter; Nakakeeto, Margaret; Oweka, James; Kurinczuk, Jennifer J; Were, Jackson; Nyombi, Natasha; Hughes, Peter; Willey, Barbara A; Elliott, Alison M; Robertson, Nicola J; Klein, Nigel; Harris, Kathryn A

    2014-01-01

    In neonatal encephalopathy (NE), infectious co-morbidity is difficult to diagnose accurately, but may increase the vulnerability of the developing brain to hypoxia-ischemia. We developed a novel panel of species-specific real-time PCR assays to identify bloodstream pathogens amongst newborns with and without NE in Uganda. Multiplex real-time PCR assays for important neonatal bloodstream pathogens (gram positive and gram negative bacteria, cytomegalovirus (CMV), herpes simplex virus(HSV) and P. falciparum) were performed on whole blood taken from 202 encephalopathic and 101 control infants. Automated blood culture (BACTEC) was performed for all cases and unwell controls. Prevalence of pathogenic bacterial species amongst infants with NE was 3.6%, 6.9% and 8.9%, with culture, PCR and both tests in combination, respectively. More encephalopathic infants than controls had pathogenic bacterial species detected (8.9%vs2.0%, p = 0.028) using culture and PCR in combination. PCR detected bacteremia in 11 culture negative encephalopathic infants (3 Group B Streptococcus, 1 Group A Streptococcus, 1 Staphylococcus aureus and 6 Enterobacteriacae). Coagulase negative staphylococcus, frequently detected by PCR amongst case and control infants, was considered a contaminant. Prevalence of CMV, HSV and malaria amongst cases was low (1.5%, 0.5% and 0.5%, respectively). This real-time PCR panel detected more bacteremia than culture alone and provides a novel tool for detection of neonatal bloodstream pathogens that may be applied across a range of clinical situations and settings. Significantly more encephalopathic infants than controls had pathogenic bacterial species detected suggesting that infection may be an important risk factor for NE in this setting.

  11. Prevalence of bloodstream pathogens is higher in neonatal encephalopathy cases vs. controls using a novel panel of real-time PCR assays.

    Directory of Open Access Journals (Sweden)

    Cally J Tann

    Full Text Available In neonatal encephalopathy (NE, infectious co-morbidity is difficult to diagnose accurately, but may increase the vulnerability of the developing brain to hypoxia-ischemia. We developed a novel panel of species-specific real-time PCR assays to identify bloodstream pathogens amongst newborns with and without NE in Uganda.Multiplex real-time PCR assays for important neonatal bloodstream pathogens (gram positive and gram negative bacteria, cytomegalovirus (CMV, herpes simplex virus(HSV and P. falciparum were performed on whole blood taken from 202 encephalopathic and 101 control infants. Automated blood culture (BACTEC was performed for all cases and unwell controls.Prevalence of pathogenic bacterial species amongst infants with NE was 3.6%, 6.9% and 8.9%, with culture, PCR and both tests in combination, respectively. More encephalopathic infants than controls had pathogenic bacterial species detected (8.9%vs2.0%, p = 0.028 using culture and PCR in combination. PCR detected bacteremia in 11 culture negative encephalopathic infants (3 Group B Streptococcus, 1 Group A Streptococcus, 1 Staphylococcus aureus and 6 Enterobacteriacae. Coagulase negative staphylococcus, frequently detected by PCR amongst case and control infants, was considered a contaminant. Prevalence of CMV, HSV and malaria amongst cases was low (1.5%, 0.5% and 0.5%, respectively.This real-time PCR panel detected more bacteremia than culture alone and provides a novel tool for detection of neonatal bloodstream pathogens that may be applied across a range of clinical situations and settings. Significantly more encephalopathic infants than controls had pathogenic bacterial species detected suggesting that infection may be an important risk factor for NE in this setting.

  12. Graphite/epoxy orthogrid panel fabrication

    Science.gov (United States)

    Lager, J. R.

    1978-01-01

    The structural concept considered for a spacecraft body structure is a grid stiffened skin with a skin laminate configuration and the stiffener grid geometry selected to best suit the design requirements. The orthogrid panel developed weighs 0.55 lb/sq ft and resisted an ultimate in-plane shear load of 545 lbf/in. The basic concept of a grid stiffener composite panel is that a relatively thin skin is reinforced with a gridwork of stiffeners so that the overall panel can resist design loads without becoming structurally unstable or being overstressed. The main feature of the orthogrid panel design is that it provides the potential for low cost structural panels when advanced to the production phase. The most innovative part of the fabrication method is the foam/fiberglass stiffener web grid billet fabrication and machining to size.

  13. Acoustically Tailored Composite Rotorcraft Fuselage Panels

    Science.gov (United States)

    Hambric, Stephen; Shepherd, Micah; Koudela, Kevin; Wess, Denis; Snider, Royce; May, Carl; Kendrick, Phil; Lee, Edward; Cai, Liang-Wu

    2015-01-01

    A rotorcraft roof sandwich panel has been redesigned to optimize sound power transmission loss (TL) and minimize structure-borne sound for frequencies between 1 and 4 kHz where gear meshing noise from the transmission has the most impact on speech intelligibility. The roof section, framed by a grid of ribs, was originally constructed of a single honeycomb core/composite face sheet panel. The original panel has coincidence frequencies near 700 Hz, leading to poor TL across the frequency range of 1 to 4 kHz. To quiet the panel, the cross section was split into two thinner sandwich subpanels separated by an air gap. The air gap was sized to target the fundamental mass-spring-mass resonance of the double panel system to less than 500 Hz. The panels were designed to withstand structural loading from normal rotorcraft operation, as well as 'man-on-the-roof' static loads experienced during maintenance operations. Thin layers of VHB 9469 viscoelastomer from 3M were also included in the face sheet ply layups, increasing panel damping loss factors from about 0.01 to 0.05. Measurements in the NASA SALT facility show the optimized panel provides 6-11 dB of acoustic transmission loss improvement, and 6-15 dB of structure-borne sound reduction at critical rotorcraft transmission tonal frequencies. Analytic panel TL theory simulates the measured performance quite well. Detailed finite element/boundary element modeling of the baseline panel simulates TL slightly more accurately, and also simulates structure-borne sound well.

  14. Paneling architectural freeform surfaces

    KAUST Repository

    Eigensatz, Michael; Kilian, Martin; Schiftner, Alexander; Mitra, Niloy J.; Pottmann, Helmut; Pauly, Mark

    2010-01-01

    with a selected technology at reasonable cost, while meeting the design intent and achieving the desired aesthetic quality of panel layout and surface smoothness. The production of curved panels is mostly based on molds. Since the cost of mold fabrication

  15. Manufacture of a four-sheet complex component from different titanium alloys by superplastic forming

    Science.gov (United States)

    Allazadeh, M. R.; Zuelli, N.

    2017-10-01

    A superplastic forming (SPF) technology process was deployed to form a complex component with eight-pocket from a four-sheet sandwich panel sheetstock. Six sheetstock packs were composed of two core sheets made of Ti-6Al-4V or Ti-5Al-4Cr-4Mo-2Sn-2Zr titanium alloy and two skin sheets made of Ti-6Al-4V or Ti-6Al-2Sn-4Zr-2Mo titanium alloy in three different combinations. The sheets were welded with two subsequent welding patterns over the core and skin sheets to meet the required component's details. The applied welding methods were intermittent and continuous resistance seam welding for bonding the core sheets to each other and the skin sheets over the core panel, respectively. The final component configuration was predicted based on the die drawings and finite element method (FEM) simulations for the sandwich panels. An SPF system set-up with two inlet gas pipe feeding facilitated the trials to deliver two pressure-time load cycles acting simultaneously which were extracted from FEM analysis for specific forming temperature and strain rate. The SPF pressure-time cycles were optimized via GOM scanning and visually inspecting some sections of the packs in order to assess the levels of core panel formation during the inflation process of the sheetstock. Two sets of GOM scan results were compared via GOM software to inspect the surface and internal features of the inflated multisheet packs. The results highlighted the capability of the tested SPF process to form complex components from a flat multisheet pack made of different titanium alloys.

  16. Solar-Panel Dust Accumulation and Cleanings

    Science.gov (United States)

    2005-01-01

    Air-fall dust accumulates on the solar panels of NASA's Mars Exploration Rovers, reducing the amount of sunlight reaching the solar arrays. Pre-launch models predicted steady dust accumulation. However, the rovers have been blessed with occasional wind events that clear significant amounts of dust from the solar panels. This graph shows the effects of those panel-cleaning events on the amount of electricity generated by Spirit's solar panels. The horizontal scale is the number of Martian days (sols) after Spirit's Jan. 4, 2005, (Universal Time) landing on Mars. The vertical scale indicates output from the rover's solar panels as a fraction of the amount produced when the clean panels first opened. Note that the gradual declines are interrupted by occasional sharp increases, such as a dust-cleaning event on sol 420.

  17. Attic Retrofits Using Nail-Base Insulated Panels

    Energy Technology Data Exchange (ETDEWEB)

    Mallay, David [Home Innovation Research Labs; Kochkin, Vladimir [Home Innovation Research Labs

    2018-03-26

    This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.

  18. Performance, Stability, and Control Investigation at Mach Numbers from 0.4 to 0.9 of a Model of the "Swallow" with Outer Wing Panels Swept 25 degree with and without Power Simulation

    Science.gov (United States)

    Runckel, Jack F.; Schmeer, James W.; Cassetti, Marlowe D.

    1960-01-01

    An investigation of the performance, stability, and control characteristics of a variable-sweep arrow-wing model (the "Swallow") with the outer wing panels swept 25 deg has been conducted in the Langley 16-foot transonic tunnel. The wing was uncambered and untwisted and had RAE 102 airfoil sections with a thickness-to-chord ratio of 0.14 normal to the leading edge. Four outboard engines located above and below the wing provided propulsive thrust, and, by deflecting in the pitch direction and rotating in the lateral plane, also produced control forces. A pair of swept lateral fins and a single vertical fin were mounted on each engine nacelle to provide aerodynamic stability and control. Jets-off data were obtained with flow-through nacelles, stimulating the effects of inlet flow; jet thrust and hot-jet interference effects were obtained with faired-nose nacelles housing hydrogen peroxide gas generators. Six-component force and moment data were obtained through a Mach number range of 0.40 to 0.90 at angles of attack and angles of sideslip from 0 deg to 15 deg. Longitudinal, directional, and lateral control were obtained by deflecting the nacelle-fin combinations as elevators, rudders, and ailerons at several fixed angles for each control.

  19. Analysing sensory panel performance in a proficiency test using the PanelCheck software

    DEFF Research Database (Denmark)

    Tomic, O.; Luciano, G.; Nilsen, A.

    2010-01-01

    Check software, a workflow is proposed that guides the user through the data analysis process. This allows practitioners and non-statisticians to get an overview over panel performances in a rapid manner without the need to be familiar with details on the statistical methods. Visualisation of data analysis...... results plays an important role as this provides a time saving and efficient way of screening and investigating sensory panel performances. Most of the statistical methods used in this paper are available in the open source software PanelCheck, which may be downloaded and used for free....

  20. A PANEL-DATA SWITCHING REGRESSION-MODEL OF MOBILITY AND CAR OWNERSHIP

    NARCIS (Netherlands)

    MEURS, H

    1993-01-01

    The objective of this paper is to present a panel data model of car ownership and mobility. Unobserved heterogeneity is controlled for by including correlated random effects in the equations describing car ownership and mobility. A mass-points approach is adopted to control for unobserved

  1. Flight service evaluation of kevlar-49 epoxy composite panels in wide-bodied commercial transport aircraft: Flight service report

    Science.gov (United States)

    Stone, R. H.

    1981-01-01

    Kevlar-49 fairing panels, installed as flight service components on three L-1011s, were inspected after 7 years service. There are six Kevlar-49 panels on each aircraft: a left hand and right hand set of a wing-body sandwich fairing; a slid laminate under-wing fillet panel; and a 422 K service aft engine fairing. The three L-1011s include one each in service with Eastern, Air Canada, and TWA. The fairings have accumulated a total of 52,500 hours, with one ship set having 17.700 hours service. The inspections were conducted at the airlines' major maintenance bases with the participation of Lockheed Engineering. The Kevlar-49 components were found to be performing satisfactorily in service with no major problems or any condition requiring corrective action. The only defects noted were minor impact damage and a minor degree of fastener hole fraying and elongation. These are for the most part comparable to damage noted on fiberglass fairings. The service history to date indicates that Kevlar-49 epoxy composite materials have satisfactory service characteristics for use in aircraft secondary structure.

  2. Implementation of Maximum Power Point Tracking (MPPT) Solar Charge Controller using Arduino

    Science.gov (United States)

    Abdelilah, B.; Mouna, A.; KouiderM’Sirdi, N.; El Hossain, A.

    2018-05-01

    the platform Arduino with a number of sensors standard can be used as components of an electronic system for acquiring measures and controls. This paper presents the design of a low-cost and effective solar charge controller. This system includes several elements such as the solar panel converter DC/DC, battery, circuit MPPT using Microcontroller, sensors, and the MPPT algorithm. The MPPT (Maximum Power Point Tracker) algorithm has been implemented using an Arduino Nano with the preferred program. The voltage and current of the Panel are taken where the program implemented will work and using this algorithm that MPP will be reached. This paper provides details on the solar charge control device at the maximum power point. The results include the change of the duty cycle with the change in load and thus mean the variation of the buck converter output voltage and current controlled by the MPPT algorithm.

  3. Evolving Systems: Adaptive Key Component Control and Inheritance of Passivity and Dissipativity

    Science.gov (United States)

    Frost, S. A.; Balas, M. J.

    2010-01-01

    We propose a new framework called Evolving Systems to describe the self-assembly, or autonomous assembly, of actively controlled dynamical subsystems into an Evolved System with a higher purpose. Autonomous assembly of large, complex flexible structures in space is a target application for Evolving Systems. A critical requirement for autonomous assembling structures is that they remain stable during and after assembly. The fundamental topic of inheritance of stability, dissipativity, and passivity in Evolving Systems is the primary focus of this research. In this paper, we develop an adaptive key component controller to restore stability in Nonlinear Evolving Systems that would otherwise fail to inherit the stability traits of their components. We provide sufficient conditions for the use of this novel control method and demonstrate its use on an illustrative example.

  4. Mounting clips for panel installation

    Science.gov (United States)

    Cavieres, Andres; Al-Haddad, Tristan; Goodman, Joseph; Valdes, Francisco

    2017-02-14

    An exemplary mounting clip for removably attaching panels to a supporting structure comprises a base, spring locking clips, a lateral flange, a lever flange, and a spring bonding pad. The spring locking clips extend upwardly from the base. The lateral flange extends upwardly from a first side of the base. The lateral flange comprises a slot having an opening configured to receive at least a portion of one of the one or more panels. The lever flange extends outwardly from the lateral flange. The spring bonding flange extends downwardly from the lever flange. At least a portion of the first spring bonding flange comprises a serrated edge for gouging at least a portion of the one or more panels when the one or more panels are attached to the mounting clip to electrically and mechanically couple the one or more panels to the mounting clip.

  5. ALDS 1978 panel review. [PNL

    Energy Technology Data Exchange (ETDEWEB)

    Hall, D.L. (ed.)

    1979-08-01

    Pacific Northwest Laboratory (PNL) is examining the analysis of large data sets (ALDS). After one year's work, a panel was convened to evaluate the project. This document is the permanent record of that panel review. It consists of edited transcripts of presentations made to the panel by the PNL staff, a summary of the responses of the panel to these presentations, and PNL's plans for the development of the ALDS project. The representations of the PNL staff described various aspects of the project and/or the philosophy surrounding the project. Supporting materials appear in appendixes. 20 figures, 4 tables. (RWR)

  6. Advanced Solar Panel Designs

    Science.gov (United States)

    Ralph, E. L.; Linder, E. B.

    1995-01-01

    Solar panel designs that utilize new high-efficiency solar cells and lightweight rigid panel technologies are described. The resulting designs increase the specific power (W/kg) achievable in the near-term and are well suited to meet the demands of higher performance small satellites (smallsats). Advanced solar panel designs have been developed and demonstrated on two NASA SBIR contracts at Applied Solar. The first used 19% efficient, large area (5.5 cm x 6.5 cm) GaAs/Ge solar cells with a lightweight rigid graphite epoxy isogrid substrate configuration. A 1,445 sq cm coupon was fabricated and tested to demonstrate 60 W/kg with a high potential of achieving 80 W/kg. The second panel design used new 22% efficiency, dual-junction GaInP2/GaAs/Ge solar cells combined with a lightweight aluminum core/graphite fiber mesh facesheet substrate. A 1,445 sq cm coupon was fabricated and tested to demonstrate 105 W/kg with the potential of achieving 115 W/kg.

  7. Effect of uncertainty components such as recalibration on the performance of quality control charts

    DEFF Research Database (Denmark)

    Winkel, P; Zhang, Nevin

    2005-01-01

    Uncertainty components (recalibration, new reagent lots, etc.) may be the source of random changes in the level of quality control (QC) values, thus causing false alarms. We propose a method for reducing false alarms.......Uncertainty components (recalibration, new reagent lots, etc.) may be the source of random changes in the level of quality control (QC) values, thus causing false alarms. We propose a method for reducing false alarms....

  8. Honeycomb metal panel

    International Nuclear Information System (INIS)

    1979-01-01

    Product constituted by a honeycomb metal panel that can be employed to advantage for manufacturing lagging by sandwiching it between two plane sheets, utilized in particular in the nuclear industry where lagging has to have a very long life strength. The honeycomb metal panel is made of an expanded metal extrusion previously cut so as to form, after additional drawing, a honeycomb structure with square or rectangular cells with a plane surface [fr

  9. Exascale Workshop Panel Report Meeting

    Energy Technology Data Exchange (ETDEWEB)

    Khaleel, Mohammad A.

    2010-07-01

    The Exascale Review Panel consists of 12 scientists and engineers with experience in various aspects of high-performance computing and its application, development, and management. The Panel hear presentations by several representatives of the workshops and town meetings convened over the past few years to examine the need for exascale computation capability and the justification for a U.S. Department of Energy (DOE) program to develop such capability. This report summarizes information provided by the presenters and substantial written reports to the Panel in advance of the meeting in Washington D.C. on January 19-20, 2010. The report also summarizes the Panel's conclusions with regard to the justification of a DOE-led exascale initiative.

  10. Structural acoustic response of a shape memory alloy hybrid composite panel (lessons learned)

    Science.gov (United States)

    Turner, Travis L.

    2002-07-01

    This study presents results from an effort to fabricate a shape memory alloy hybrid composite (SMAHC) panel specimen and test the structure for dynamic response and noise transmission characteristics under the action of thermal and random acoustic loads. A method for fabricating a SMAHC laminate with bi-directional SMA reinforcement is described. Glass-epoxy unidirectional prepreg tape and Nitinol ribbon comprise the material system. Thermal activation of the Nitinol actuators was achieved through resistive heating. The experimental hardware required for mechanical support of the panel/actuators and for establishing convenient electrical connectivity to the actuators is presented. Other experimental apparatus necessary for controlling the panel temperature and acquiring structural acoustic data are also described. Deficiency in the thermal control system was discovered in the process of performing the elevated temperature tests. Discussion of the experimental results focuses on determining the causes for the deficiency and establishing means for rectifying the problem.

  11. Labor Costs and Foreign Direct Investment: A Panel VAR Approach

    OpenAIRE

    Bahar Bayraktar-Sağlam; Selin Sayek Böke

    2017-01-01

    This paper examines the endogenous interaction between labor costs and Foreign Direct Investment (FDI) in the OECD countries via the Panel VAR approach under system GMM estimates for the period 1995–2009. The available data allows identifying the relevance of the components of labor costs, and allows a detailed analysis across different sectors. Empirical findings have revealed that sectoral composition of FDI and the decomposition of labor costs play a significant role in investigating the d...

  12. Procurement and quality control of components important to safety in nuclear engineering projects

    International Nuclear Information System (INIS)

    Zhang Zhihua; Zhang Yiyun

    2006-01-01

    The procurement and quality control of components is a very important work in the nuclear engineering. This paper introduces the project management techniques, such as how to make a plan of components purchase in nuclear engineering. This paper discussed the classification of components, evaluation of the potential suppliers, invitation of bids, exchange of design details with the suppliers, quality assurance and quality assurance audit, and the equipment checks before acceptance and some engineering experiences. (authors)

  13. PERFORMANCE OF RC AND FRC WALL PANELS REINFORCED WITH MILD STEEL AND GFRP COMPOSITES IN BLAST EVENTS

    Energy Technology Data Exchange (ETDEWEB)

    Timothy Garfield; William D. Richins; Thomas K. Larson; Chris P. Pantelides; James E. Blakeley

    2011-06-01

    The structural integrity of reinforced concrete structures in blast events is important for critical facilities. This paper presents experimental data generated for calibrating detailed finite element models that predict the performance of reinforced concrete wall panels with a wide range of construction details under blast loading. The test specimens were 1.2 m square wall panels constructed using Normal Weight Concrete (NWC) or Fiber Reinforced Concrete (FRC). FRC consists of macro-synthetic fibers dispersed in NWC. Five types of panels were tested: NWC panels with steel bar reinforcement (Type A); FRC panels without additional reinforcement (Type B); FRC panels with steel bar reinforcement (Type C); NWC panels with glass fiber reinforced polymer (GFRP) bar reinforcement (Type D); and NWC panels reinforced with steel bar reinforcement and external bidirectional GFRP overlays on both faces (Type E). An additional three Type C panels were used as control specimens (CON). Each panel type was constructed with three thicknesses: 152 mm, 254 mm, and 356 mm. The panels were instrumented with strain gauges, and accelerometers; in addition, pressure sensors and high speed videos were employed during the blast events. Panel types C and E had the best performance, whereas panel type B did not perform well. Preliminary dynamic simulations show crack patterns similar to the experimental results.

  14. Improving Survey Response Rates in Online Panels

    DEFF Research Database (Denmark)

    Pedersen, Mogens Jin; Nielsen, Christian Videbæk

    2016-01-01

    Identifying ways to efficiently maximize the response rate to surveys is important to survey-based research. However, evidence on the response rate effect of donation incentives and especially altruistic and egotistic-type text appeal interventions is sparse and ambiguous. By a randomized survey...... experiment among 6,162 members of an online survey panel, this article shows how low-cost incentives and cost-free text appeal interventions may impact the survey response rate in online panels. The experimental treatments comprise (a) a cash prize lottery incentive, (b) two donation incentives equating...... survey response with a monetary donation to a good cause, (c) an egotistic-type text appeal, and (d) an altruistic-type text appeal. Relative to a control group, we find higher response rates among the recipients of the egotistic-type text appeal and the lottery incentive. Donation incentives yield lower...

  15. Quality control in digital mammography: the noise components

    Energy Technology Data Exchange (ETDEWEB)

    Leyton, Fernando [Universidade de Tarapaca, Arica (Chile). Centro de Estudios en Ciencias Radiologicas; Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Nogueira, Maria do Socorro, E-mail: mnogue@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Duran, Maria Paz [Clinica Alemana, Santiago (Chile). Dept. de Radiologia; Dantas, Marcelino, E-mail: marcelino@inb.gov.b [Industrias Nucleares do Brasil (INB), Caldas, MG (Brazil). Unidade de Tratamento de Minerios; Ubeda, Carlos, E-mail: cubeda@uta.c [Universidade de Tarapaca, Arica (Chile). Fac. de Ciencias de la Salud

    2011-07-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  16. Quality control in digital mammography: the noise components

    International Nuclear Information System (INIS)

    Leyton, Fernando; Nogueira, Maria do Socorro; Duran, Maria Paz; Dantas, Marcelino; Ubeda, Carlos

    2011-01-01

    To measure the linearity of the detector and determine the noise components (quantum, electronic and structural noise) that contributed to losing image quality and to determine the signal noise ratio (SNR) and contrast noise ratio (CNR). This paper describes the results of the implementation of a protocol for quality control in digital mammography performed in two direct digital mammography equipment (Hologic, Selenia) in Santiago of Chile. Shows the results of linearity and noise analysis of the images which establishes the main cause of noise in the image of the mammogram to ensure the quality and optimize procedures. The study evaluated two digital mammography's Selenia, Hologic (DR) from Santiago, Chile. We conducted the assessment of linearity of the detector, the signal noise ratio, contrast noise ratio and was determined the contribution of different noise components (quantum, electronics and structural noise). Used different thicknesses used in clinical practice according to the protocol for quality control in digital mammography of Spanish society of medical physics and NHSBSP Equipment Report 0604 Version 3. The Selenia mammography software was used for the analysis of images and Unfors Xi detector for measuring doses. The mammography detector has a linear performance, the CNR and SNR did not comply with the Protocol for the thicknesses of 60 and 70 mm. The main contribution of the noise corresponds to the quantum noise, therefore it is necessary to adjust and optimize the mammography system. (author)

  17. Grounds of two positions photovoltaic panels

    OpenAIRE

    Castán Fortuño, Fernando

    2008-01-01

    The objective of this Master Thesis is to find the optimum positioning for a two positions photovoltaic panel. Hence, it will be implemented a model in order to optimize the energy of the sun that the photovoltaic panel is receiving by its positioning. Likewise this project will include the comparison with other photovoltaic panel systems as the single position photovoltaics panels. Ultimately, it is also going to be designed a system array for the optimized model of two positions photovoltai...

  18. Orbiter radiator panel solar focusing test

    Science.gov (United States)

    Howell, H. R.; Rankin, J. G.

    1983-01-01

    Test data are presented which define the area around the Orbiter radiator panels for which the solar reflections are concentrated to one-sun or more. The concave shape of the panels and their specular silver/Teflon coating causes focusing of the reflected solar energy which could have adverse heating effects on equipment or astronaut extravehicular activity (EVA) in the vicinity of the radiator panels. A room ambient test method was utilized with a one-tenth scale model of the radiator panels.

  19. Components of Standing Postural Control Evaluated in Pediatric Balance Measures: A Scoping Review.

    Science.gov (United States)

    Sibley, Kathryn M; Beauchamp, Marla K; Van Ooteghem, Karen; Paterson, Marie; Wittmeier, Kristy D

    2017-10-01

    To identify measures of standing balance validated in pediatric populations, and to determine the components of postural control captured in each tool. Electronic searches of MEDLINE, Embase, and CINAHL databases using key word combinations of postural balance/equilibrium, psychometrics/reproducibility of results/predictive value of tests, and child/pediatrics; gray literature; and hand searches. Inclusion criteria were measures with a stated objective to assess balance, with pediatric (≤18y) populations, with at least 1 psychometric evaluation, with at least 1 standing task, with a standardized protocol and evaluation criteria, and published in English. Two reviewers independently identified studies for inclusion. There were 21 measures included. Two reviewers extracted descriptive characteristics, and 2 investigators independently coded components of balance in each measure using a systems perspective for postural control, an established framework for balance in pediatric populations. Components of balance evaluated in measures were underlying motor systems (100% of measures), anticipatory postural control (72%), static stability (62%), sensory integration (52%), dynamic stability (48%), functional stability limits (24%), cognitive influences (24%), verticality (9%), and reactive postural control (0%). Assessing children's balance with valid and comprehensive measures is important for ensuring development of safe mobility and independence with functional tasks. Balance measures validated in pediatric populations to date do not comprehensively assess standing postural control and omit some key components for safe mobility and independence. Existing balance measures, that have been validated in adult populations and address some of the existing gaps in pediatric measures, warrant consideration for validation in children. Copyright © 2017 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  20. Sound Transmission Through Multi-Panel Structures Lined with Elastic Porous Materials

    Science.gov (United States)

    Bolton, J. S.; Shiau, N.-M.; Kang, Y. J.

    1996-04-01

    Theory and measurements related to sound transmission through double panels lined with elastic porous media are presented. The information has application to the design of noise control barriers and to the optimization of aircraft fuselage transmission loss, for example. The major difference between the work described here and earlier research in this field relates to the treatment of the porous material that is used to line the cavity between the two panels of the double panel structure. Here we have used the porous material theory proposed by Biot since it takes explicit account of all the wave types known to propagate in elastic porous materials. As a result, it is possible to use the theory presented here to calculate the transmission loss of lined double panels at arbitrary angles of incidence; results calculated over a range of incidence angles may then be combined to yield the random incidence transmission loss. In this paper, the equations governing wave propagation in an elastic porous material are first considered briefly and then the general forms for the stresses and displacements within the porous material are given. Those solutions are expressed in terms of a number of constants that can be determined by application of appropriate boundary conditions. The boundary conditions required to model double panels having linings that are either directly attached to the facing panels or separated?!from them by air gaps are presented and discussed. Measurements of the random incidence transmission loss of aluminium double-panel structures lined with polyurethane foam are presented and have been found to be in good agreement with theoretical predictions. Both the theoretical predictions and the measured results have shown that the method by which an elastic porous lining material is attached to the facing panels can have a profound influence on the transmission loss of the panel system. It has been found, for example, that treatments in which the lining material

  1. FEMA DFIRM Panel Scheme Polygons

    Data.gov (United States)

    Minnesota Department of Natural Resources — This layer contains information about the Flood Insurance Rate Map (FIRM) panel areas. The spatial entities representing FIRM panels are polygons. The polygon for...

  2. Bridge between control science and technology. Volume 5 Manufacturing man-machine systems, computers, components, traffic control, space applications

    Energy Technology Data Exchange (ETDEWEB)

    Rembold, U; Kempf, K G; Towill, D R; Johannsen, G; Paul, M

    1985-01-01

    Among the topics discussed are: robotics; CAD/CAM applications; and man-machine systems. Consideration is also given to: tools and software for system design and integration; communication systems for real-time computer control; fail-safe design of real-time computer systems; and microcomputer-based control systems. Additional topics discussed include: programmable and intelligent components and instruments in automatic control; transportation systems; and space applications of automatic control systems.

  3. 21 CFR 516.141 - Qualified expert panels.

    Science.gov (United States)

    2010-04-01

    ... choose members for the qualified expert panel in accordance with selection criteria listed in paragraph... whether the proposed qualified expert panel meets the selection criteria prior to the panel beginning its... Committee Act, as amended, 5 U.S.C. App. (b) Criteria for the selection of a qualified expert panel. (1) A...

  4. Localized Effects in the Nonlinear Behavior of Sandwich Panels with a Transversely Flexible Core

    DEFF Research Database (Denmark)

    Frostig, Y.; Thomsen, Ole Thybo

    2005-01-01

    This paper presents the results of an investigation of the role of localized effects within the geometrically nonlinear domain on structural sandwich panels with a "compliant" core. Special emphasis is focused on the nonlinear response near concentrated loads and stiffened core regions. The adopted...... nonlinear analysis approach incorporates the effects of the vertical flexibility of the core, and it is based on the approach of the High-order Sandwich Panel Theory (HSAPT). The results demonstrate that the effects of localized loads, when taken into the geometrically nonlinear domain, change the response...... of the panel from a strength problem controlled by stress constraints into a stability problem with unstable limit point behavior when force-controlled loads are applied. The stability problem emerge as the nonlinear response develops with the formation of a small number of buckling waves in the compressed...

  5. Is Job Control a Double-Edged Sword? A Cross-Lagged Panel Study on the Interplay of Quantitative Workload, Emotional Dissonance, and Job Control on Emotional Exhaustion.

    Science.gov (United States)

    Konze, Anne-Kathrin; Rivkin, Wladislaw; Schmidt, Klaus-Helmut

    2017-12-20

    Previous meta-analytic findings have provided ambiguous evidence on job control as a buffering moderator of the adverse impact of job demands on psychological well-being. To disentangle these mixed findings, we examine the moderating effect of job control on the adverse effects of quantitative workload and emotional dissonance as distinct work-related demands on emotional exhaustion over time. Drawing on the job demands-control model, the limited strength model of self-control, and the matching principle we propose that job control can facilitate coping with work-related demands but at the same time may also require employees' self-control. Consequently, we argue that job control buffers the adverse effects of quantitative workload while it reinforces the adverse effects of emotional dissonance, which also necessitates self-control. We examine the proposed relations among employees from an energy supplying company ( N = 139) in a cross-lagged panel study with a six-month time lag. Our results demonstrate a mix of causal and reciprocal effects of job characteristics on emotional exhaustion over time. Furthermore, as suggested, our data provides evidence for contrasting moderating effects of job control. That is, job control buffers the adverse effects of quantitative workload while it reinforces the adverse effects of emotional dissonance on emotional exhaustion.

  6. Is Job Control a Double-Edged Sword? A Cross-Lagged Panel Study on the Interplay of Quantitative Workload, Emotional Dissonance, and Job Control on Emotional Exhaustion

    Directory of Open Access Journals (Sweden)

    Anne-Kathrin Konze

    2017-12-01

    Full Text Available Previous meta-analytic findings have provided ambiguous evidence on job control as a buffering moderator of the adverse impact of job demands on psychological well-being. To disentangle these mixed findings, we examine the moderating effect of job control on the adverse effects of quantitative workload and emotional dissonance as distinct work-related demands on emotional exhaustion over time. Drawing on the job demands-control model, the limited strength model of self-control, and the matching principle we propose that job control can facilitate coping with work-related demands but at the same time may also require employees’ self-control. Consequently, we argue that job control buffers the adverse effects of quantitative workload while it reinforces the adverse effects of emotional dissonance, which also necessitates self-control. We examine the proposed relations among employees from an energy supplying company (N = 139 in a cross-lagged panel study with a six-month time lag. Our results demonstrate a mix of causal and reciprocal effects of job characteristics on emotional exhaustion over time. Furthermore, as suggested, our data provides evidence for contrasting moderating effects of job control. That is, job control buffers the adverse effects of quantitative workload while it reinforces the adverse effects of emotional dissonance on emotional exhaustion.

  7. Reliability Study in Solar Panels

    OpenAIRE

    Español Lifante, Albert

    2012-01-01

    Crystalline silicon Modules are formed by single silicon photovoltaic cells. Since each one of these cells individually contributes to the overall electric power of the panel, the failure of one of them directly affects to its benefits and performance. To Minimize these negative effects, junction boxes with few bypass diodes are usually included in Photovoltaic Solar panels. A still experimental way to built solar panels is to integrate bypass diodes in every single cell, which would in...

  8. Sound transmission loss of composite sandwich panels

    Science.gov (United States)

    Zhou, Ran

    Light composite sandwich panels are increasingly used in automobiles, ships and aircraft, because of the advantages they offer of high strength-to-weight ratios. However, the acoustical properties of these light and stiff structures can be less desirable than those of equivalent metal panels. These undesirable properties can lead to high interior noise levels. A number of researchers have studied the acoustical properties of honeycomb and foam sandwich panels. Not much work, however, has been carried out on foam-filled honeycomb sandwich panels. In this dissertation, governing equations for the forced vibration of asymmetric sandwich panels are developed. An analytical expression for modal densities of symmetric sandwich panels is derived from a sixth-order governing equation. A boundary element analysis model for the sound transmission loss of symmetric sandwich panels is proposed. Measurements of the modal density, total loss factor, radiation loss factor, and sound transmission loss of foam-filled honeycomb sandwich panels with different configurations and thicknesses are presented. Comparisons between the predicted sound transmission loss values obtained from wave impedance analysis, statistical energy analysis, boundary element analysis, and experimental values are presented. The wave impedance analysis model provides accurate predictions of sound transmission loss for the thin foam-filled honeycomb sandwich panels at frequencies above their first resonance frequencies. The predictions from the statistical energy analysis model are in better agreement with the experimental transmission loss values of the sandwich panels when the measured radiation loss factor values near coincidence are used instead of the theoretical values for single-layer panels. The proposed boundary element analysis model provides more accurate predictions of sound transmission loss for the thick foam-filled honeycomb sandwich panels than either the wave impedance analysis model or the

  9. 75 FR 82376 - North American Free Trade Agreement, Article 1904 NAFTA Panel Reviews; Request for Panel Review

    Science.gov (United States)

    2010-12-30

    ... Mexico and the People's Republic of China. This determination was published in the Federal Register (75... Panel Review. SUMMARY: On December 22, 2010, the Government of Mexico filed a First Request for Panel... Government of Mexico established Rules of Procedure for Article 1904 Binational Panel Reviews (``Rules...

  10. Centers for Disease Control review panel's recommendations on health effects and epidemiological studies of operations at the Savannah River Plant, Aiken, South Carolina. Public comment and meeting report

    Energy Technology Data Exchange (ETDEWEB)

    1985-05-01

    Based on the request of the US Department of Energy, the Centers for Disease Control of the US Department of Health and Human Services organized a panel to review the feasibility and usefulness of conducting further epidemiologic studies of delayed health effects around the Department of Energy's Savannah River Plant. The review and recommendations of the panel were documented in a report entitled Epidemiologic Projects Considered Possible to Undertake in Populations Around the Savannah River Plant. On November 30, 1984, the Department of Energy announced in the Federal Register (49 FR 47095) the conduct of a public meeting and a 30-day public comment period between December 1 and December 30, 1984, on the recommendations of the review panel. Based on the requests of individuals and representatives of organizations attending the December 18, 1984, public meetings, the Department of Energy subsequently announced in the Federal Register on December 31, 1984 (49 FR 50767) an extension of the public comment period to January 31, 1985. This report documents the public meeting and comment process, and provides responses to the public comments that were submitted during this process. In addition, this report contains the Department of Energy's position based on the recommendations of the Centers for Disease Control review panel and the public comments. 23 refs., 16 tabs.

  11. Energy management algorithm for an optimum control of a photovoltaic water pumping system

    International Nuclear Information System (INIS)

    Sallem, Souhir; Chaabene, Maher; Kamoun, M.B.A.

    2009-01-01

    The effectiveness of photovoltaic water pumping systems depends on the adequacy between the generated energy and the volume of pumped water. This paper presents an intelligent algorithm which makes decision on the interconnection modes and instants of photovoltaic installation components: battery, water pump and photovoltaic panel. The decision is made by fuzzy rules on the basis of the Photovoltaic Panel Generation (PVPG) forecast during a considered day, on the load required power, and by considering the battery safety. The algorithm aims to extend operation time of the water pump by controlling a switching unit which links the system components with respect to multi objective management criteria. The algorithm implementation demonstrates that the approach extends the pumping period for more than 5 h a day which gives a mean daily improvement of 97% of the water pumped volume.

  12. A hierarchically structured identification- and classification method for vibration control of reactor components

    International Nuclear Information System (INIS)

    Saedtler, E.

    1981-01-01

    The method for controlling the vibrating behaviour of primary circuit components or for a general systems control is a combination of methods of the statistic systems theory, optimum filter theory, statistic decision theory and of the pattern recognition method. It is appropriate for automatic control of complex systems and stochastic events. (DG) [de

  13. User manual for SPLASH (Single Panel Lamp and Shroud Helper).

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Marvin Elwood

    2006-02-01

    The radiant heat test facility develops test sets providing well-characterized thermal environments, often representing fires. Many of the components and procedures have become standardized to such an extent that the development of a specialized design tool to determine optimal configurations for radiant heat experiments was appropriate. SPLASH (Single Panel Lamp and Shroud Helper) is that tool. SPLASH is implemented as a user-friendly, Windows-based program that allows a designer to describe a test setup in terms of parameters such as number of lamps, power, position, and separation distance. This document is a user manual for that software. Any incidental descriptions of theory are only for the purpose of defining the model inputs. The theory for the underlying model is described in SAND2005-2947 (Ref. [1]). SPLASH provides a graphical user interface to define lamp panel and shroud designs parametrically, solves the resulting radiation enclosure problem for up to 2500 surfaces, and provides post-processing to facilitate understanding and documentation of analyzed designs.

  14. Development of Electrostatically Clean Solar Array Panels

    Science.gov (United States)

    Stern, Theodore G.

    2000-01-01

    Certain missions require Electrostatically Clean Solar Array (ECSA) panels to establish a favorable environment for the operation of sensitive scientific instruments. The objective of this program was to demonstrate the feasibility of an ECSA panel that minimizes panel surface potential below 100mV in LEO and GEO charged particle environments, prevents exposure of solar cell voltage and panel insulating surfaces to the ambient environment, and provides an equipotential, grounded structure surrounding the entire panel. An ECSA panel design was developed that uses a Front Side Aperture-Shield (FSA) that covers all inter-cell areas with a single graphite composite laminate, composite edge clips for connecting the FSA to the panel substrate, and built-in tabs that interconnect the FSA to conductive coated coverglasses using a conductive adhesive. Analysis indicated the ability of the design to meet the ECSA requirements. Qualification coupons and a 0.5m x 0.5m prototype panel were fabricated and tested for photovoltaic performance and electrical grounding before and after exposure to acoustic and thermal cycling environments. The results show the feasibility of achieving electrostatic cleanliness with a small penalty in mass, photovoltaic performance and cost, with a design is structurally robust and compatible with a wide range of current solar panel technologies.

  15. Solar panel foundation device

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.W.

    1983-03-29

    A transportable solar panel foundation device which has a bottom member, at least one upstanding side member, and an essentially open top. The side members are angled to permit nesting of a plurality of the foundation devices, and reinforcement pads are carried by the foundation device to support legs for one or more solar panels.

  16. Components of effective randomized controlled trials of hydrotherapy programs for fibromyalgia syndrome: A systematic review.

    Science.gov (United States)

    Perraton, Luke; Machotka, Zuzana; Kumar, Saravana

    2009-11-30

    Previous systematic reviews have found hydrotherapy to be an effective management strategy for fibromyalgia syndrome (FMS). The aim of this systematic review was to summarize the components of hydrotherapy programs used in randomized controlled trials. A systematic review of randomized controlled trials was conducted. Only trials that have reported significant FMS-related outcomes were included. Data relating to the components of hydrotherapy programs (exercise type, duration, frequency and intensity, environmental factors, and service delivery) were analyzed. Eleven randomized controlled trials were included in this review. Overall, the quality of trials was good. Aerobic exercise featured in all 11 trials and the majority of hydrotherapy programs included either a strengthening or flexibility component. Great variability was noted in both the environmental components of hydrotherapy programs and service delivery. Aerobic exercise, warm up and cool-down periods and relaxation exercises are common features of hydrotherapy programs that report significant FMS-related outcomes. Treatment duration of 60 minutes, frequency of three sessions per week and an intensity equivalent to 60%-80% maximum heart rate were the most commonly reported exercise components. Exercise appears to be the most important component of an effective hydrotherapy program for FMS, particularly when considering mental health-related outcomes.

  17. A review of sensing technologies for small and large-scale touch panels

    Science.gov (United States)

    Akhtar, Humza; Kemao, Qian; Kakarala, Ramakrishna

    2017-06-01

    A touch panel is an input device for human computer interaction. It consists of a network of sensors, a sampling circuit and a micro controller for detecting and locating a touch input. Touch input can come from either finger or stylus depending upon the type of touch technology. These touch panels provide an intuitive and collaborative workspace so that people can perform various tasks with the use of their fingers instead of traditional input devices like keyboard and mouse. Touch sensing technology is not new. At the time of this writing, various technologies are available in the market and this paper reviews the most common ones. We review traditional designs and sensing algorithms for touch technology. We also observe that due to its various strengths, capacitive touch will dominate the large-scale touch panel industry in years to come. In the end, we discuss the motivation for doing academic research on large-scale panels.

  18. Numerical Study for Compressive Strength of Basalt Composite Sandwich Infill Panel

    OpenAIRE

    Viriyavudh Sim; Jung Kyu Choi; Yong Ju Kwak; Oh Hyeon Jeon; Woo Young Jung

    2017-01-01

    In this study, we investigated the buckling performance of basalt fiber reinforced polymer (BFRP) sandwich infill panels. Fiber Reinforced Polymer (FRP) is a major evolution for energy dissipation when used as infill material of frame structure, a basic Polymer Matrix Composite (PMC) infill wall system consists of two FRP laminates surrounding an infill of foam core. Furthermore, this type of component is for retrofitting and strengthening frame structure to withstand the seismic disaster. In...

  19. The study of fix composite panel and steel plates on testing stand

    Science.gov (United States)

    Wróbel, A.; Płaczek, M.; Wachna, M.

    2016-08-01

    In this paper the practical possibilities of strength verification analysis of composite materials used in the manufacture of selected components of railway wagons are presented. Real laboratory stand for measurements in a scale controlled by PLC controller were made. The study of different types of connections of composite materials with sheet metal is presented. In one of the chapter of this paper principles construction of testing stand with pneumatic cylinder were presented. Mainly checking of displacements and stresses generated on the sheet as a result of pneumatic actuators load for composite boards was carried out. The use of the controller with operating panel allows to easy programming testing cycle. The user can define the force generated by the actuator by change of air pressure in cylinder. Additionally the location of acting cylinders and their jump can be changed by operator. The examination of the volume displacements was done by displacement sensor, and the tensile strain gauge. All parameters are written in CatmanEasy - data acquisition software. This article presents the study of stresses and displacements in the composite plates joined with sheet metal, in summary of this article, the authors compare the obtained results with the computer simulation results in the article: "Simulation of stresses in an innovative combination of composite with sheet".

  20. 10-MWe pilot-plant-receiver panel test requirements document solar thermal test facility

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-25

    Testing plans for a full-scale test receiver panel and supporting hardware which essentially duplicate both physically and functionally, the design planned for the Barstow Solar Pilot Plant are presented. Testing is to include operation during normal start and shutdown, intermittent cloud conditions, and emergencies to determine the panel's transient and steady state operating characteristics and performance under conditions equal to or exceeding those expected in the pilot plant. The effects of variations of input and output conditions on receiver operation are also to be investigated. Test hardware are described, including the pilot plant receiver, the test receiver assembly, receiver panel, flow control, electrical control and instrumentation, and structural assembly. Requirements for the Solar Thermal Test Facility for the tests are given. The safety of the system is briefly discussed, and procedures are described for assembly, installation, checkout, normal and abnormal operations, maintenance, removal and disposition. Also briefly discussed are quality assurance, contract responsibilities, and test documentation. (LEW)

  1. PVT Panels. Fully renewable and competitive

    International Nuclear Information System (INIS)

    Bakker, M.; Strootman, K.J.; Jong, M.J.M.

    2003-10-01

    A photovoltaic/thermal (PVT) panel is a combination of photovoltaic cells with a solar thermal collector, generating solar electricity and solar heat simultaneously. PVT panels generate more solar energy per unit surface area than a combination of separate PV panels and solar thermal collectors, and share the aesthetic advantage of PV. After several years of research, PVT panels have been developed into a product that is now ready for market introduction. One of the most promising system concepts, consisting of 25 m 2 of PVT panels and a ground coupled heat pump, has been simulated in TRNSYS, and has been found to be able to fully cover both the building related electricity and heat consumption, while keeping the long-term average ground temperature constant. The cost and payback time of such a system have been determined; it has been found that the payback time of this system is approximately two-thirds of the payback time of an identical system but with 21 m 2 of PV panels and 4 m 2 of solar thermal collectors. Finally, by looking at the expected growth in the PV and solar thermal collector market, the market potential for for PVT panels has been found to be very large

  2. Panel cutting method: new approach to generate panels on a hull in Rankine source potential approximation

    Directory of Open Access Journals (Sweden)

    Hee-Jong Choi

    2011-12-01

    Full Text Available In the present study, a new hull panel generation algorithm, namely panel cutting method, was developed to predict flow phenomena around a ship using the Rankine source potential based panel method, where the iterative method was used to satisfy the nonlinear free surface condition and the trim and sinkage of the ship was taken into account. Numerical computations were performed to investigate the validity of the proposed hull panel generation algorithm for Series 60 (CB=0.60 hull and KRISO container ship (KCS, a container ship designed by Maritime and Ocean Engineering Research Institute (MOERI. The computational results were validated by comparing with the existing experimental data.

  3. Panel cutting method: new approach to generate panels on a hull in Rankine source potential approximation

    Science.gov (United States)

    Choi, Hee-Jong; Chun, Ho-Hwan; Park, Il-Ryong; Kim, Jin

    2011-12-01

    In the present study, a new hull panel generation algorithm, namely panel cutting method, was developed to predict flow phenomena around a ship using the Rankine source potential based panel method, where the iterative method was used to satisfy the nonlinear free surface condition and the trim and sinkage of the ship was taken into account. Numerical computations were performed to investigate the validity of the proposed hull panel generation algorithm for Series 60 (CB=0.60) hull and KRISO container ship (KCS), a container ship designed by Maritime and Ocean Engineering Research Institute (MOERI). The computational results were validated by comparing with the existing experimental data.

  4. Residual-strength tests of L-1011 vertical fin components after 10 and 20 years of simulated flight service

    Science.gov (United States)

    Lopez, O. F.

    1984-01-01

    Part of the NASA/ACEE Program was to determine the effect of long-term durability testing on the residual strength of graphite-epoxy cover panel and spar components of the Lockheed L-1011 aircraft vertical stabilizer. The results of these residual strength tests are presented herein. The structural behavior and failure mode of both cover panel and spar components were addressed, and the test results obtained were compared with the static test results generated by Lockheed. The effect of damage on one of the spar specimens was described.

  5. Effect of air flow, panel curvature, and internal pressurization on field-incidence transmission loss

    Science.gov (United States)

    Koval, L. R.

    1976-01-01

    In the context of sound transmission through aircraft fuselage panels, equations for the field-incidence transmission loss (TL) of a single-walled panel are derived that include the effects of external air flow, panel curvature, and internal fuselage pressurization. Flow is shown to provide a modest increase in TL that is uniform with frequency up to the critical frequency. The increase is about 2 dB at Mach number M = 0.5, and about 3.5 dB at M = 1. Above the critical frequency where TL is damping controlled, the increase can be slightly larger at certain frequencies. Curvature is found to stiffen the panel, thereby increasing the TL at low frequencies, but also to introduce a dip at the 'ring frequency' of a full cylinder having the same radius as the panel. Pressurization appears to produce a slight decrease in TL throughout the frequency range, and also slightly shifts the dips at the critical frequency and at the ring frequency.

  6. Design and R&D for manufacturing the beamline components of MITICA and ITER HNBs

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Palma, M., E-mail: mauro.dallapalma@igi.cnr.it [Consorzio RFX, Padova (Italy); Sartori, E. [Consorzio RFX, Padova (Italy); Blatchford, P.; Chuilon, B. [CCFE, Culham Science Centre, Oxfordshire (United Kingdom); Graceffa, J. [ITER Organization, St Paul Lez Durance (France); Hanke, S. [KIT, Institute for Technical Physics, Eggenstein-Leopoldshafen (Germany); Hardie, C. [CCFE, Culham Science Centre, Oxfordshire (United Kingdom); Masiello, A. [F4E, Barcelona (Spain); Muraro, A. [Consorzio RFX, Padova (Italy); Ochoa, S. [KIT, Institute for Technical Physics, Eggenstein-Leopoldshafen (Germany); Shah, D. [ITER Organization, St Paul Lez Durance (France); Veltri, P.; Zaccaria, P.; Zaupa, M. [Consorzio RFX, Padova (Italy)

    2015-10-15

    Highlights: • Particle beam-component interaction was analysed developing and applying numerical codes. • Gas density distribution was calculated with AVOCADO code and applied for electrical analyses. • High heat flux components were designed, analysed with subcooled boiling, verified for fatigue. • Fracture behaviour of ceramics was analysed by finite element modelling and was verified. • R&D supports the design of the beamline components, especially for water-vacuum barriers. - Abstract: The design of the beamline components of MITICA, the full prototype of the ITER heating neutral beam injectors, is almost finalised and technical specifications for the procurement are under preparation. These components are the gas neutraliser, the electrostatic residual ion dump, and the calorimeter. Electron dump panels are foreseen each side of the upstream end of the neutraliser to protect the cryo-panels from electrons, created by stripping and other processes, that exit the 1 MeV accelerator. As the design of the components must fulfil requirements on the beam physics, insight on physical processes is required to identify performance trade-offs and constraints. The spatial gas distribution was simulated to verify the pumping requirements with electron dump panels and local conditions for breakdown voltage. Electrostatic analyses were carried out for the insulating elements of the RID to verify the limits of the electric field intensity. Different criteria were approached to investigate the fracture behaviour of ceramics considering the manufacturing implications and extrapolating the conditions for proof testing. Severe heating conditions will be applied steadily, as the maximum pulse duration is 1 h, and cyclically so requiring to fulfil fatigue and ratcheting verifications. High heat fluxes, up to 13 MW/m{sup 2} on the calorimeter, with enhanced heat transfer in subcooled boiling conditions will occur in the actively cooled CuCr1Zr panel elements provided with

  7. Industrial waste utilization in the panels production for high buildings facade and socle facing

    Science.gov (United States)

    Vitkalova, Irina; Torlova, Anastasiya; Pikalov, Evgeniy; Selivanov, Oleg

    2018-03-01

    The research presents comprehensive utilization of such industrial waste as galvanic sludge, broken window glass as functional additives for producing ceramics for facade and socle paneling in high-rise construction. The basic charge component is low-plasticity clay, which does not allow producing high-quality products if used without any functional additives. The application of the mentioned above components broadens the resource base, reduces production cost and the mass of the products in comparison with the currently used facing ceramics. The decrease of product mass helps to reduce the load on the basement and to use ceramic material in high-rise construction more effectively. Additional advantage of the developed composition is the reducing of production energy intensity due to comparatively low pressing pressure and firing temperature thus reducing the overall production cost. The research demonstrates the experimental results of determining density, compressive strength, water absorption, porosity and frost resistance of the produced ceramic material. These characteristics prove that the material can be applied for high buildings outdoor paneling. Additional research results prove ecologic safety of the produced ceramic material.

  8. A Study on Components of Internal Control-Based Administrative System in Secondary Schools

    Science.gov (United States)

    Montri, Paitoon; Sirisuth, Chaiyuth; Lammana, Preeda

    2015-01-01

    The aim of this study was to study the components of the internal control-based administrative system in secondary schools, and make a Confirmatory Factor Analysis (CFA) to confirm the goodness of fit of empirical data and component model that resulted from the CFA. The study consisted of three steps: 1) studying of principles, ideas, and theories…

  9. Computational and experimental studies of microvascular void features for passive-adaptation of structural panel dynamic properties

    Science.gov (United States)

    Sears, Nicholas C.; Harne, Ryan L.

    2018-01-01

    The performance, integrity, and safety of built-up structural systems are critical to their effective employment in diverse engineering applications. In conflict with these goals, harmonic or random excitations of structural panels may promote large amplitude oscillations that are particularly harmful when excitation energies are concentrated around natural frequencies. This contributes to fatigue concerns, performance degradation, and failure. While studies have considered active or passive damping treatments that adapt material characteristics and configurations for structural control, it remains to be understood how vibration properties of structural panels may be tailored via internal material transitions. Motivated to fill this knowledge gap, this research explores an idea of adapting the static and dynamic material distribution of panels through embedded microvascular channels and strategically placed voids that permit the internal movement of fluids within the panels for structural dynamic control. Finite element model and experimental investigations probe how redistributing material in the form of microscale voids influences the global vibration modes and natural frequencies of structural panels. Through parameter studies, the relationships among void shape, number, size, and location are quantified towards their contribution to the changing structural dynamics. For the panel composition and boundary conditions considered in this report, the findings reveal that transferring material between strategically placed voids may result in eigenfrequency changes as great as 10.0, 5.0, and 7.4% for the first, second, and third modes, respectively.

  10. Solar panel assembly and support pad

    Energy Technology Data Exchange (ETDEWEB)

    Hawley, W.W.

    1980-10-07

    A solar panel assembly is described comprising at least one solar panel, support means for carrying said panel, and at least one support pad having a base plate, upstanding longitudinal sides, and spaced apart flange means for connection to said support means, said upstanding sides and opposed flange means defining an interior volume for receiving and holding weighting material.

  11. JERAMI SEBAGAI BAHAN BAKU PANEL AKUSTIK PELAPIS DINDING

    Directory of Open Access Journals (Sweden)

    Christina E. Mediastika

    2008-01-01

    Full Text Available The demand of walling panels with acoustic qualification has surprisingly increased, due to the needs for home theaters and mini recording studios in the increase of environmental noise. Therefore, good supply of acoustic panels, especially those with lower price are necessary. A series of study to explore possibility in using paddy-straw as main material to construct cheap and high quality panels has been developed. Prior to this study, an earlier small research showed there was a great potency in using paddy-straw as panels, especially ones drawn from paddy in type IR. The earlier study recommends further research to examine strength of compression and tensile of the constructed panels to go for building materials, which is presented in this paper. Acoustic qualification of the panels is subject for further reserach. Abstract in Bahasa Indonesia: Kebutuhan akan panel pelapis dinding yang bersifat akustik terus meningkat seiring meningkatnya kebisingan dan kebutuhan terhadap ruang studio pribadi. Ketersediaan panel pelapis dinding dengan harga yang lebih terjangkau seperti yang terbuat dari bahan limbah sangatlah dibutuhkan. Pada penelitian awal telah diselidiki kemungkinan penggunaan jerami yang merupakan limbah sebagai bahan baku pembuatan panel akustik. Penelitian tersebut menunjukkan bahwa jerami sangat potensial digunakan sebagai bahan aku panel, terutama jerami padi berjenis IR. Selanjutnya panel jerami ini perlu mendapatkan perlakukan uji desak dan lentur untuk memastikan kemampuannya menahan berat sendiri dan kekuatannya saat proses penggunaan, sebelum akhirnya mengalami pengujian berkaitan dengan kualitas akustik. Kekuatan desak dan lentur panel dimaksud, tersaji dalam tulisan ini. Kata kunci: panel jerami, uji desak, uji lentur.

  12. Advisory panel on the proposed New Brunswick - Quebec electricity transaction

    International Nuclear Information System (INIS)

    Ganong, D.A.

    2010-01-01

    NB Power was faced with major financial and technical challenges in generation that would lead to significant rate increases over several years to come. In 2009, the governments of New Brunswick and Quebec proposed an agreement whereby Hydro-Quebec would acquire most of the assets of NB Power and provide a guaranteed electricity supply at a set price to the province. The proposal involved the sale of NB Power's hydro generation facilities, 2 diesel peaking plants and the Point Lepreau nuclear generating facility. It also included a guaranteed bulk electricity supply of 14 Terawatt-hours per year by Hydro-Quebec at a blended rate of 7.35 cents per kilowatt-hour. The new Brunswick government would retain ownership of the fossil-fuelled power plants, the NB Power transmission assets and the NB Power distribution assets and customer sales. A 6-person independent panel was asked to examine the proposal. This report addresses the proposed agreement as presented to the Panel up to January 26, 2010. The panel conducted an independent and objective examination of the financial implications; long-term effects on electricity rates; New Brunswick's control of energy policies; environmental impacts; short-and long-term risks and avoided risks; and benefits and costs to the provincial economy. The Panel drew its conclusions and recommendations on the basis of available information. The Panel concluded that the benefits to New Brunswick contribute to real and positive value to New Brunswick over business as usual. tabs., figs.

  13. Components of effective randomized controlled trials of hydrotherapy programs for fibromyalgia syndrome: A systematic review

    Directory of Open Access Journals (Sweden)

    Luke Perraton

    2009-11-01

    Full Text Available Luke Perraton, Zuzana Machotka, Saravana KumarInternational Centre for Allied Health Evidence, University of South Australia, Adelaide, South Australia, AustraliaAim: Previous systematic reviews have found hydrotherapy to be an effective management strategy for fibromyalgia syndrome (FMS. The aim of this systematic review was to summarize the components of hydrotherapy programs used in randomized controlled trials.Method: A systematic review of randomized controlled trials was conducted. Only trials that have reported significant FMS-related outcomes were included. Data relating to the components of hydrotherapy programs (exercise type, duration, frequency and intensity, environmental factors, and service delivery were analyzed.Results: Eleven randomized controlled trials were included in this review. Overall, the quality of trials was good. Aerobic exercise featured in all 11 trials and the majority of hydrotherapy programs included either a strengthening or flexibility component. Great variability was noted in both the environmental components of hydrotherapy programs and service delivery.Conclusions: Aerobic exercise, warm up and cool-down periods and relaxation exercises are common features of hydrotherapy programs that report significant FMS-related outcomes. Treatment duration of 60 minutes, frequency of three sessions per week and an intensity equivalent to 60%–80% maximum heart rate were the most commonly reported exercise components. Exercise appears to be the most important component of an effective hydrotherapy program for FMS, particularly when considering mental health-related outcomes.Keywords: hydrotherapy, fibromyalgia syndrome, exercise, effective, components

  14. Report of Industry Panel Group

    Science.gov (United States)

    Gallimore, Simon; Gier, Jochen; Heitland, Greg; Povinelli, Louis; Sharma, Om; VandeWall, Allen

    2006-01-01

    A final report is presented from the industry panel group. The contents include: 1) General comments; 2) Positive progress since Minnowbrook IV; 3) Industry panel outcome; 4) Prioritized turbine projects; 5) Prioritized compressor projects; and 6) Miscellaneous.

  15. How do different components of Effortful Control contribute to children's mathematics achievement?

    Directory of Open Access Journals (Sweden)

    Noelia eSánchez-Pérez

    2015-09-01

    Full Text Available This work sought to investigate the specific contribution of two different components of Effortful Control -attentional focusing and inhibitory control- to children’s mathematics achievement. The sample was composed of 142 children aged 9 to 12 years old. Effortful Control components were measured through the Temperament in Middle Childhood Questionnaire (TMCQ; parent´s report; math achievement was measured via teacher’s report and through the standard Woodcock-Johnson test. Additionally, the contribution of other cognitive and socio-emotional processes was taken into account. Our results showed that only attentional focusing significantly contributed to the variance of children’s mathematics achievement; interestingly, mediational models showed that the relationship between effortful attentional self-regulation and mathematics achievement was mediated by academic peer popularity, as well as by intelligence and study skills. Results are discussed in the light of the current theories on the role of children’ self-regulation abilities in the context of school.

  16. Nova laser alignment control system

    International Nuclear Information System (INIS)

    Van Arsdall, P.J.; Holloway, F.W.; McGuigan, D.L.; Shelton, R.T.

    1984-01-01

    Alignment of the Nova laser requires control of hundreds of optical components in the ten beam paths. Extensive application of computer technology makes daily alignment practical. The control system is designed in a manner which provides both centralized and local manual operator controls integrated with automatic closed loop alignment. Menudriven operator consoles using high resolution color graphics displays overlaid with transport touch panels allow laser personnel to interact efficiently with the computer system. Automatic alignment is accomplished by using image analysis techniques to determine beam references points from video images acquired along the laser chain. A major goal of the design is to contribute substantially to rapid experimental turnaround and consistent alignment results. This paper describes the computer-based control structure and the software methods developed for aligning this large laser system

  17. KUALITAS AKUSTIK PANEL DINDING BERBAHAN BAKU JERAMI

    Directory of Open Access Journals (Sweden)

    Christina E. Mediastika

    2008-01-01

    Full Text Available A series of study to explore possibility in using paddy-straw as main material to construct cheap and high quality panels has been developed. Prior to this study, laboratory research to examine strength of compression and tensile of the panels have been conducted, which is showed a significant value for a non-structural panel. The compression is 15 N/mm2 and tensile averaged at 0,5 N/mm2 . In this study, acoustic properties of the panels is to be examined, i.e.: transmission loss (TL, absorption coefficient (, and reverberation time (RT60. The test showed TL of 10 dB and 16 dB,  of 0,4 and 0,8 and improve RT60 from 0,88 sec to 0,35 sec and 0,16 sec (500 Hz is used for reference. Abstract in Bahasa Indonesia: Ketersediaan panel pelapis dinding yang bersifat akustik dengan harga yang lebih terjangkau seperti yang terbuat dari bahan limbah sangatlah penting. Pada penelitian awal telah diselidiki penggunaan jerami sebagai bahan baku pembuatan panel akustik, sekaligus telah dilakukan pengujian terhadap kareakteristik struktural (uji desak dan lentur dari panel tersebut. Dari uji kekuatan struktural, panel memiliki kekuatan desak mencapai 15 N/mm2 dan kuat lentur reta-rata 0,5 N/mm2. Kekuatan ini dianggap mencukupi bagi panel non-struktural yang hanya bertugas untuk memikul beban sendiri. Oleh karena tujuan awal pembuatan panel adalah untuk kepentingan akustik, maka pada penelitian lanjutan, dilakukan uji laboratorium dan lapangan untuk melihat karakterisktik akustiknya. Adapun pengujian meliputi: redaman/insulasi (TL, koefisien serap ( dan waktu dengung (RT60. Dari hasil pengujian, panel mempunyai TL 10 dB dan 16 dB,  0,4 dan 0,8, serta mampu memperbaiki RT60 ruangan dari 0,88 detik menjadi 0,35 detik dan 0,16 detik. Kesemua pengujian menggunakan band frekuensi 500 Hz sebagai acuan. Kata kunci: panel jerami, insulasi, koefisien serap, waktu dengung.

  18. Aerospace Safety Advisory Panel

    Science.gov (United States)

    1999-01-01

    This report covers the activities of the Aerospace Safety Advisory Panel (ASAP) for calendar year 1998-a year of sharp contrasts and significant successes at NASA. The year opened with the announcement of large workforce cutbacks. The slip in the schedule for launching the International Space Station (ISS) created a five-month hiatus in Space Shuttle launches. This slack period ended with the successful and highly publicized launch of the STS-95 mission. As the year closed, ISS assembly began with the successful orbiting and joining of the Functional Cargo Block (FGB), Zarya, from Russia and the Unity Node from the United States. Throughout the year, the Panel maintained its scrutiny of NASA's safety processes. Of particular interest were the potential effects on safety of workforce reductions and the continued transition of functions to the Space Flight Operations Contractor. Attention was also given to the risk management plans of the Aero-Space Technology programs, including the X-33, X-34, and X-38. Overall, the Panel concluded that safety is well served for the present. The picture is not as clear for the future. Cutbacks have limited the depth of talent available. In many cases, technical specialties are 'one deep.' The extended hiring freeze has resulted in an older workforce that will inevitably suffer significant departures from retirements in the near future. The resulting 'brain drain' could represent a future safety risk unless appropriate succession planning is started expeditiously. This and other topics are covered in the section addressing workforce. The major NASA programs are also limited in their ability to plan property for the future. This is of particular concern for the Space Shuttle and ISS because these programs are scheduled to operate well into the next century. In the case of the Space Shuttle, beneficial and mandatory safety and operational upgrades are being delayed because of a lack of sufficient present funding. Likewise, the ISS has

  19. Prioritization of reactor control components susceptible to fire damage as a consequence of aging

    International Nuclear Information System (INIS)

    Lowry, W.; Vigil, R.; Nowlen, S.

    1994-01-01

    The Fire Vulnerability of Aged Electrical Components Test Program is to identify and assess issues of plant aging that could lead to an increase in nuclear power plant risk because of fires. Historical component data and prior analyses are used to prioritize a list of components with respect to aging and fire vulnerability and the consequences of their failure on plant safety systems. The component list emphasizes safety system control components, but excludes cables, large equipment, and devices encompassed in the Equipment Qualification (EQ) program. The test program selected components identified in a utility survey and developed test and fire conditions necessary to maximize the effectiveness of the test program. Fire damage considerations were limited to purely thermal effects

  20. Alternative Shutdown Panel. Amaraz Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Saenz de Santa Maria Valin, J.

    2016-07-01

    Between 2010 and 2014 the Nuclear Power Plant of Almaraz conducted one of the most complex projects in its history: The installation of an Alternative Shutdown Panel with the capability to stop the plant in case of fire in the Control room or in the Cable room. This project represented a great economic and organizational effort for the plant, but at the same time has been a great improvement in the safety of the installation, which was demonstrated by the achievement of a major milestone in the history of Almaraz: The actual shutdown from outside of the Control room. (Author)

  1. Optimal locations of piezoelectric patches for supersonic flutter control of honeycomb sandwich panels, using the NSGA-II method

    International Nuclear Information System (INIS)

    Nezami, M; Gholami, B

    2016-01-01

    The active flutter control of supersonic sandwich panels with regular honeycomb interlayers under impact load excitation is studied using piezoelectric patches. A non-dominated sorting-based multi-objective evolutionary algorithm, called non-dominated sorting genetic algorithm II (NSGA-II) is suggested to find the optimal locations for different numbers of piezoelectric actuator/sensor pairs. Quasi-steady first order supersonic piston theory is employed to define aerodynamic loading and the p-method is applied to find the flutter bounds. Hamilton’s principle in conjunction with the generalized Fourier expansions and Galerkin method are used to develop the dynamical model of the structural systems in the state-space domain. The classical Runge–Kutta time integration algorithm is then used to calculate the open-loop aeroelastic response of the system. The maximum flutter velocity and minimum voltage applied to actuators are calculated according to the optimal locations of piezoelectric patches obtained using the NSGA-II and then the proportional feedback is used to actively suppress the closed loop system response. Finally the control effects, using the two different controllers, are compared. (paper)

  2. Components of the costs of controlling quality: a transaction cost economics approach.

    Science.gov (United States)

    Stiles, R A; Mick, S S

    1997-01-01

    This article identifies the components that contribute to a healthcare organization's costs in controlling quality. A central tenet of our argument is that at its core, quality is the result of a series of transactions among members of a diverse network. Transaction cost economics is applied internally to analyze intraorganizational transactions that contribute to quality control, and questions for future research are posed.

  3. Panel Smooth Transition Regression Models

    DEFF Research Database (Denmark)

    González, Andrés; Terasvirta, Timo; Dijk, Dick van

    We introduce the panel smooth transition regression model. This new model is intended for characterizing heterogeneous panels, allowing the regression coefficients to vary both across individuals and over time. Specifically, heterogeneity is allowed for by assuming that these coefficients are bou...

  4. Nonlinear vibration and radiation from a panel with transition to chaos induced by acoustic waves

    Science.gov (United States)

    Maestrello, Lucio; Frendi, Abdelkader; Brown, Donald E.

    1992-01-01

    The dynamic response of an aircraft panel forced at resonance and off-resonance by plane acoustic waves at normal incidence is investigated experimentally and numerically. Linear, nonlinear (period doubling) and chaotic responses are obtained by increasing the sound pressure level of the excitation. The response time history is sensitive to the input level and to the frequency of excitation. The change in response behavior is due to a change in input conditions, triggered either naturally or by modulation of the bandwidth of the incident waves. Off-resonance, bifurcation is diffused and difficult to maintain, thus the panel response drifts into a linear behavior. The acoustic pressure emanated by the panel is either linear or nonlinear as is the vibration response. The nonlinear effects accumulate during the propagation with distance. Results are also obtained on the control of the panel response using damping tape on aluminum panel and using a graphite epoxy panel having the same size and weight. Good agreement is obtained between the experimental and numerical results.

  5. Hexagon solar power panel

    Science.gov (United States)

    Rubin, I. (Inventor)

    1978-01-01

    A solar energy panel support is described upon which silicon cells are arrayed. The cells are wafer thin and of two geometrical types, both of the same area and electrical rating, namely hexagon cells and hourglass cells. The hourglass cells are composites of half hexagons. A near perfect nesting relationship of the cells achieves a high density packing whereby optimum energy production per panel area is achieved.

  6. Inequality and development: Evidence from semiparametric estimation with panel data

    OpenAIRE

    Zhou, X.; Li, Kui-Wai

    2011-01-01

    Evidences from nonparametric and semiparametric unbalanced panel data models with fixed effects show that Kuznet’s inverted-U relationship is confirmed when economic development reaches a threshold. The model tests justify semiparametric specification. The integrated net contribution of control variables to inequality reduction is significant.

  7. Developing a HACCP-like system for improving animal health and welfare in organic egg production - based on an expert panel analysis

    DEFF Research Database (Denmark)

    Hegelund, Lene; Sørensen, Jan Tind

    2007-01-01

    In the process of developing a generic Hazard Analysis and Critical Control Point (HACCP)-like system for securing animal health and welfare in organic egg production, an expert panel analysis was used to perform the initial hazard analysis. Eighteen advisers and researchers in organic egg...... specific systems. An expert panel analysis based on questionnaires was a useful tool during the first steps of developing a HACCP plan, conducting a hazard analysis and suggesting control points. However, care should be taken regarding the panel's size and fields of expertise in order to assure...... that the panel fully covers the field of interest throughout the study. A further development of the hazard analysis into a farm-specific HACCP system would include assembling an on-farm HACCP team consisting of farmers and advisors for the practical application of control points, alarm values and monitoring...

  8. PV panel model based on datasheet values

    DEFF Research Database (Denmark)

    Sera, Dezso; Teodorescu, Remus; Rodriguez, Pedro

    2007-01-01

    This work presents the construction of a model for a PV panel using the single-diode five-parameters model, based exclusively on data-sheet parameters. The model takes into account the series and parallel (shunt) resistance of the panel. The equivalent circuit and the basic equations of the PV cell....... Based on these equations, a PV panel model, which is able to predict the panel behavior in different temperature and irradiance conditions, is built and tested....

  9. Ottawa Panel evidence-based clinical practice guidelines for therapeutic exercise in the management of hip osteoarthritis.

    Science.gov (United States)

    Brosseau, Lucie; Wells, George A; Pugh, Arlanna G; Smith, Christine Am; Rahman, Prinon; Àlvarez Gallardo, Inmaculada C; Toupin-April, Karine; Loew, Laurianne; De Angelis, Gino; Cavallo, Sabrina; Taki, Jade; Marcotte, Rachel; Fransen, Marlene; Hernandez-Molina, Gabriela; Kenny, Glen P; Regnaux, Jean-Philippe; Lefevre-Colau, Marie-Martine; Brooks, Sydney; Laferriere, Lucie; McLean, Linda; Longchamp, Guy

    2016-10-01

    The primary objective is to identify effective land-based therapeutic exercise interventions and provide evidence-based recommendations for managing hip osteoarthritis. A secondary objective is to develop an Ottawa Panel evidence-based clinical practice guideline for hip osteoarthritis. The search strategy and modified selection criteria from a Cochrane review were used. Studies included hip osteoarthritis patients in comparative controlled trials with therapeutic exercise interventions. An Expert Panel arrived at a Delphi survey consensus to endorse the recommendations. The Ottawa Panel hierarchical alphabetical grading system (A, B, C+, C, D, D+, or D-) considered the study design (level I: randomized controlled trial and level II: controlled clinical trial), statistical significance (p osteoarthritis. Strength training exercises displayed the greatest improvements for pain (Grade A), disability (Grades A and C+), physical function (Grade A), stiffness (Grade A), and range of motion (Grade A) within a short time period (8-24 weeks). Stretching also greatly improved physical function (Grade A), and flexibility exercises improved pain (Grade A), range of motion (Grade A), physical function (Grade A), and stiffness (Grade C+). The Ottawa Panel recommends land-based therapeutic exercise, notably strength training, for management of hip osteoarthritis in reducing pain, stiffness and self-reported disability, and improving physical function and range of motion. © The Author(s) 2015.

  10. Sound transmission through lined, composite panel structures: Transversely isotropic poro-elastic model

    Science.gov (United States)

    Kim, Jeong-Woo

    A joint experimental and analytical investigation of the sound transmission loss (STL) and two-dimensional free wave propagation in composite sandwich panels is presented here. An existing panel, a Nomex honeycomb sandwich panel, was studied in detail. For the purpose of understanding the typical behavior of sandwich panels, a composite structure comprising two aluminum sheets with a relatively soft, poro-elastic foam core was also constructed and studied. The cores of both panels were modeled using an anisotropic (transversely isotropic) poro-elastic material theory. Several estimation methods were used to obtain the material properties of the honeycomb core and the skin plates to be used in the numerical calculations. Appropriate values selected from among the estimates were used in the STL and free wave propagation models. The prediction model was then verified in two ways: first, the calculated wave speeds and STL of a single poro-elastic layer were numerically verified by comparison with the predictions of a previously developed isotropic model. Secondly, to physically validate the transversely isotropic model, the measured STL and the phase speeds of the sandwich panels were compared with their predicted values. To analyze the actual treatment of a fuselage structure, multi-layered configurations, including a honeycomb panel and several layers such as air gaps, acoustic blankets and membrane partitions, were formulated. Then, to find the optimal solution for improving the sound barrier performance of an actual fuselage system, air layer depth and glass fiber lining effects were investigated by using these multi-layer models. By using the free wave propagation model, the first anti-symmetric and symmetric modes of the sandwich panels were characterized to allow the identification of the coincidence frequencies of the sandwich panel. The behavior of the STL could then be clearly explained by comparison with the free wave propagation solutions. By performing a

  11. Use of statistical process control in the production of blood components

    DEFF Research Database (Denmark)

    Magnussen, K; Quere, S; Winkel, P

    2008-01-01

    Introduction of statistical process control in the setting of a small blood centre was tested, both on the regular red blood cell production and specifically to test if a difference was seen in the quality of the platelets produced, when a change was made from a relatively large inexperienced...... by an experienced staff with four technologists. We applied statistical process control to examine if time series of quality control values were in statistical control. Leucocyte count in red blood cells was out of statistical control. Platelet concentration and volume of the platelets produced by the occasional...... occasional component manufacturing staff to an experienced regular manufacturing staff. Production of blood products is a semi-automated process in which the manual steps may be difficult to control. This study was performed in an ongoing effort to improve the control and optimize the quality of the blood...

  12. Aerosol Deposition and Solar Panel Performance

    Science.gov (United States)

    Arnott, W. P.; Rollings, A.; Taylor, S. J.; Parks, J.; Barnard, J.; Holmes, H.

    2015-12-01

    Passive and active solar collector farms are often located in relatively dry desert regions where cloudiness impacts are minimized. These farms may be susceptible to reduced performance due to routine or episodic aerosol deposition on collector surfaces. Intense episodes of wind blown dust deposition may negatively impact farm performance, and trigger need to clean collector surfaces. Aerosol deposition rate depends on size, morphology, and local meteorological conditions. We have developed a system for solar panel performance testing under real world conditions. Two identical 0.74 square meter solar panels are deployed, with one kept clean while the other receives various doses of aerosol deposition or other treatments. A variable load is used with automation to record solar panel maximum output power every 10 minutes. A collocated sonic anemometer measures wind at 10 Hz, allowing for both steady and turbulent characterization to establish a link between wind patterns and particle distribution on the cells. Multispectral photoacoustic instruments measure aerosol light scattering and absorption. An MFRSR quantifies incoming solar radiation. Solar panel albedo is measured along with the transmission spectra of particles collected on the panel surface. Key questions are: At what concentration does aerosol deposition become a problem for solar panel performance? What are the meteorological conditions that most strongly favor aerosol deposition, and are these predictable from current models? Is it feasible to use the outflow from an unmanned aerial vehicle hovering over solar panels to adequately clean their surface? Does aerosol deposition from episodes of nearby forest fires impact performance? The outlook of this research is to build a model that describes environmental effects on solar panel performance. Measurements from summer and fall 2015 will be presented along with insights gleaned from them.

  13. General stability of composite panels reinforced with flexible rods taking account of the side boundary conditions

    Science.gov (United States)

    Dudchenko, A. A.; Elpat'evskii, A. N.

    1995-07-01

    Reinforced panels are the basic load-bearing elements of various structures. Optimization of massive structures requires consideration of deformation of the panel cross-sections. This is particularly important in determining the bearing strength at buckling. The load scheme, conditions for fixation of the panel cross-section, and bend-torsional stiffness taking account of the deformation of the rod cross-section affect the buckling load in real structures. The stress distribution prior to buckling must be known to solve the buckling problem properly. The stress in the panel is proportional to the active load. The stress distribution is assumed to be known according to our previous method [1]. The load scheme and panel dimensions are shown in Fig. 1. The stress distribution in the panel prior to buckling can be found using Eqs. (1)-(3). A view of the cross-section is given in Fig. 1. The displacements in the panel at buckling for the boundary area are found using Eqs. (4)-(6), while the stresses in the skin and stiffness are found using Eq. (7). Roots k1 and k2 are those of the characteristic equation and β is a dimensionless coordinate. The problem was solved using variational theory. The potential energy is given by Eqs. (8) and (9) by orihogonalization of Eqs. (5). The basic equations are converted to Eqs. (10) by evaluation of the components in Eqs. (8) and (9). Its calculation (11) gives the compression load. Optimization of parameter α gives the critical strength P1 = 6.93 kN (without taking account of the boundary area) and P2 = 5.31 kN (taking account of the boundary area).

  14. Numerical simulation of wind loads on solar panels

    Science.gov (United States)

    Su, Kao-Chun; Chung, Kung-Ming; Hsu, Shu-Tsung

    2018-05-01

    Solar panels mounted on the roof of a building or ground are often vulnerable to strong wind loads. This study aims to investigate wind loads on solar panels using computational fluid dynamic (CFD). The results show good agreement with wind tunnel data, e.g. the streamwise distribution of mean surface pressure coefficient of a solar panel. Wind uplift for solar panels with four aspect ratios is evaluated. The effect of inclined angle and clearance (or height) of a solar panel is addressed. It is found that wind uplift of a solar panel increases when there is an increase in inclined angle and the clearance above ground shows an opposite effect.

  15. Validation Studies of the Human Movement Analysis Panel for Hand/Arm Performance

    OpenAIRE

    Smith, Charles D.; Walton, Ashley; Slevin, John T.; Gerhardt, Greg A.; Umberger, Gloria; Smoot, Kyle; Schulze, Emily; Gash, Don

    2007-01-01

    The human movement analysis panel (HMAP) measures separable components of arm motion and simple and complex finger coordination. HMAP testing takes 30 minutes to administer. In separate experiments we have validated the HMAP against the standard grooved pegboard and measures of gait speed, and demonstrated important learning effects over both short durations of days, and longer intervals of months to years in normal subjects of different ages. Stepwise regression demonstrated the strongest co...

  16. Integrally rigidized acoustic interior spacecraft panel

    Science.gov (United States)

    1976-01-01

    A sandwich panel concept is described which utilizes a monolithic I-beam design as the core. The core and skins are integrally bonded with thermosetting resin into a homogeneous structure. In addition to possessing a high strength to weight ratio, the panel resists combustion, delamination, aging due to fatigue, localized stresses, and exhibits good acoustic properties. Since the panel concept has definite potential as a high flame retardant and low smoke emission panel with excellent structural integrity, aerospace materials were used to optimize the construction for highly demanding space shuttle applications. The specific materials of construction were chosen for low flammability and off-gassing properties as well as for strength, light weight, and sound dampening.

  17. Matlab Software for Spatial Panels

    NARCIS (Netherlands)

    Elhorst, J.Paul

    2014-01-01

    Elhorst provides Matlab routines to estimate spatial panel data models at his website. This article extends these routines to include the bias correction procedure proposed by Lee and Yu if the spatial panel data model contains spatial and/or time-period fixed effects, the direct and indirect

  18. Panel 3 - characterization

    Energy Technology Data Exchange (ETDEWEB)

    Erck, R.A.; Erdemir, A.; Janghsing Hsieh; Lee, R.H.; Xian Zheng Pan; Deming Shu [Argonne National Lab., IL (United States); Feldman, A. [National Inst. of Standards and Technology, Gaithersburg, MD (United States); Glass, J.T. [North Carolina State Univ., Raleigh (United States); Kleimer, R. [Coors Ceramics Co., Golden, CO (United States); Lawton, E.A. [JPL/Caltech, Pasadena, CA (United States); McHargue, C.J. [Univ. of Tennessee, Knoxville (United States)

    1993-01-01

    The task of this panel was to identify and prioritize needs in the area of characterization of diamond and diamond-like-carbon (DLC) films for use in the transportation industry. Until recent advances in production of inexpensive films of diamonds and DLC, it was not feasible that these materials could be mass produced. The Characterization Panel is restricting itself to identifying needs in areas that would be most useful to manufacturers and users in producing and utilizing diamond and DLC coatings in industry. These characterization needs include in-situ monitoring during growth, relation of structure to performance, and standards and definitions.

  19. Development of panel loudspeaker system: design, evaluation and enhancement.

    Science.gov (United States)

    Bai, M R; Huang, T

    2001-06-01

    Panel speakers are investigated in terms of structural vibration and acoustic radiation. A panel speaker primarily consists of a panel and an inertia exciter. Contrary to conventional speakers, flexural resonance is encouraged such that the panel vibrates as randomly as possible. Simulation tools are developed to facilitate system integration of panel speakers. In particular, electro-mechanical analogy, finite element analysis, and fast Fourier transform are employed to predict panel vibration and the acoustic radiation. Design procedures are also summarized. In order to compare the panel speakers with the conventional speakers, experimental investigations were undertaken to evaluate frequency response, directional response, sensitivity, efficiency, and harmonic distortion of both speakers. The results revealed that the panel speakers suffered from a problem of sensitivity and efficiency. To alleviate the problem, a woofer using electronic compensation based on H2 model matching principle is utilized to supplement the bass response. As indicated in the result, significant improvement over the panel speaker alone was achieved by using the combined panel-woofer system.

  20. Foaming of CRT panel glass powder using Na2CO3

    DEFF Research Database (Denmark)

    Petersen, Rasmus Rosenlund; König, Jakob; Smedskjær, Morten Mattrup

    2014-01-01

    The recycling of glass from obsolete cathode ray tubes (CRT) has hitherto only occurred to a very limited extent, but the production of foam glass used as an insulation material component has recently been proposed as a promising recycling method. CRT panel glass has high recycling potential due...... to its non-hazardous composition. Here we report on the foaming of CRT panel glass using Na2CO3 as the foaming agent. We explore how heat treatment temperature and concentration of Na2CO3 affect the density and porosity of the foam glasses, and whether Na2O is incorporated in the glass network....... The optimum foaming temperature for minimising density and maximising closed porosity is found to be between 1023 and 1123 K. The pore structure depends on the amount of added Na2CO3, viz, the pores generally become more open with increasing Na2CO3 content. A minimum density of 0·28 g/cm3 is found when 14 wt...