WorldWideScience

Sample records for control conditions part

  1. Bio boiler - Control conditions. Part 1: Model development and analysis of operating conditions; Biokedel - Reguleringsmaessige forhold. Del 1: Modeludvikling og analyse af dynamiske driftsforhold

    Energy Technology Data Exchange (ETDEWEB)

    Boecher Poulsen, K.; Christensen, Torkild; Mortensen, Jan; Runge Kristoffersen, J.; Kristmundsson, E. [Tech-wise A/S (Denmark); Moekbak, T.; Mortensen, Hans Peter [Elsam A/S (Denmark)

    2002-12-15

    This report focuses on the model-building part of the PSO project, 'Control Conditions Bio-boiler'. In the project, which treats dynamic simulation of biomass fired power plants via the MMS software, a certain number of straw/wood chip modules have been built, together with a combustion module which, when connected to the existing MMS modules, can be used for dynamic simulation. Furthermore, a certain number of continuous and discrete components have been built which, together with the remaining MMS modules will create a complete model of the active part of the control structure under the most common operation conditions. By means of the developed straw, combustion and control modules, a model of Enstedvaerket's bio-boiler is built (without wood chip super-heater), including practically all auxiliary control mechanisms. In the report the primary problems caused by the development of the model are discussed, typically numerical problems. First of all it is discussed how a steady state condition can be reached from a nonphysical condition at the start-up of the simulation. After reaching a steady state condition at full load, the boiler load is reduced by adjusting the desired live steam flow setpoint value and the load gradient (as it would be done from the control room). While reducing to part load, one straw line is closed down, as it would be done in 'real life'. From part load, the boiler load is once again in the same way increased to full. (BA) The simulation results are then compared to measurements made on the same boiler during load reduction and load increase.

  2. Condition based spare parts supply

    NARCIS (Netherlands)

    Lin, X.; Basten, Robertus Johannes Ida; Kranenburg, A.A.; van Houtum, Geert-Jan

    2012-01-01

    We consider a spare parts stock point that serves an installed base of machines. Each machine contains the same critical component, whose degradation behavior is described by a Markov process. We consider condition based spare parts supply, and show that an optimal, condition based inventory policy

  3. Controlled parts management

    International Nuclear Information System (INIS)

    Boyle, C.M.; Hidalgo, S.P.; Martinez, B.J.

    2004-01-01

    The Controlled Parts Management (CPM) system is based on industry standard practices for managing inventory. CPM is designed to record the movement of any type of inventory in a defined region referred to as an Account or SubAccount. The system is used to track the receiving, processing, storing and transfer of inventory parts. CPM provides information on parts, quantity and the exact location of the inventory. CPM is a barcode-based-part tracking system currently used to track controlled parts that are used in the R and D and testing of weapons; this tracking helps maintain the part pedigree that is required for certification of a weapon or weapon test. CPM includes bar code data collection software programmed into portable bar code readers for automating physical inventory services and remote transaction capture. CPM interfaces to other Engineering systems and supports a 'material content' of a weapons test through the test Bill of Materials and assignment of a unique inventory part in CPM. Additional functionality includes the ability to group or join parts, logically or physically and temporary or permanent, to represent discrete parts, containers, subassemblies and assemblies, and groupings.

  4. Stimulus control: Part I

    OpenAIRE

    Dinsmoor, James A.

    1995-01-01

    In his effort to distinguish operant from respondent conditioning, Skinner stressed the lack of an eliciting stimulus and rejected the prevailing stereotype of Pavlovian “stimulus—response” psychology. But control by antecedent stimuli, whether classified as conditional or discriminative, is ubiquitous in the natural setting. With both respondent and operant behavior, symmetrical gradients of generalization along unrelated dimensions may be obtained following differential reinforcement in the...

  5. Mosquito Control: Do Your Part

    Centers for Disease Control (CDC) Podcasts

    Everyone can do their part to help control mosquitoes that can carry viruses like West Nile, Zika, dengue and chikungunya. In each episode of this podcast, you will learn ways to help reduce the number of mosquitoes in and around your home.

  6. Conditioning of tritiated wastes. Part II

    International Nuclear Information System (INIS)

    Hawthorne, S.H.

    1984-01-01

    Work is continuing on the development of conditioning systems for low and intermediate level tritiated liquid and solid wastes which will prevent loss of tritium for at least 150 years. This portion of the program has concentrated on solidification and encapsulation of tritiated aqueous wastes, development of techniques, for the measurement of tritium loss in air and water, and identification and evaluation of encapsulation materials. Solidification of tritiated aqueous wastes by water extendible polyester or cements resulted in average tritium releases of approximately 1-4x10 -1 α/day with that from water extendible polyester being the lowest. The daily release rate is independent of initial tritium concentration in the waste form and can be reduced by a factor of 1000 by encapsultation of the waste within a 10 mm layer of water extendible polyester. Water extendible polyester is the preferred material for solidification and encapsulation of aqueous tritiated wastes and encapsulation of tritiated solids permitting release of only 3x10 -3 % of the original activity over 150 years. It is expected that this program which was originally scheduled for three years can now be completed in two years with complete definition of the conditioning system including the outer package

  7. Survey of Jaemtland county (basement rock part). Geologic conditions

    International Nuclear Information System (INIS)

    Antal, I.; Bergman, S.; Freden, C.; Gierup, J.; Stoelen, L.K.; Thunholm, B.; Stephens, M.

    1999-06-01

    A broad survey of the geologic conditions in Jaemtland county is presented, with the aim to give background for the location of a repository for spent fuels. The study is restricted to the basement rock part of the county

  8. Survey of Dalarna county (basement rock part). Geologic conditions

    International Nuclear Information System (INIS)

    Gierup, J.; Kuebler, L.; Linden, A.; Ripa, M.; Stoelen, L.K.; Thunholm, B.; Stephens, M.

    1999-06-01

    A broad survey of the geologic conditions in Dalarna county is presented, with the aim to give background for the location of a repository for spent fuels. The study is restricted to the basement rock part of the county

  9. Survey of Scania county (basement rock part). Geologic conditions

    International Nuclear Information System (INIS)

    Gierup, J.; Kuebler, L.; Pamnert, M.; Persson, Magnus; Thunholm, B.; Wahlgren, C.H.; Wikman, H.; Stephens, M.

    1999-06-01

    A broad survey of the geologic conditions in Scania county is presented, with the aim to give background for the location of a repository for spent fuels. The study is restricted to the basement rock part of the county

  10. 40 CFR Appendix A to Part 33 - Term and Condition

    Science.gov (United States)

    2010-07-01

    ... contractor to carry out these requirements is a material breach of this contract which may result in the.... 33, App. A Appendix A to Part 33—Term and Condition Each procurement contract signed by an EPA... this contract. The contractor shall carry out applicable requirements of 40 CFR part 33 in the award...

  11. Intelligent control of HVAC systems. Part I: Modeling and synthesis

    Directory of Open Access Journals (Sweden)

    Adrian TOADER

    2013-03-01

    Full Text Available This is the first part of a work on intelligent type control of Heating, Ventilating and Air-Conditioning (HVAC systems. The study is performed from the perspective of giving a unitary control method to ensure high energy efficiency and air quality improving. To illustrate the proposed HVAC control technique, in this first part it is considered as benchmark problem a single thermal space HVAC system. The construction of the mathematical model is performed only with a view to obtain a framework of HVAC intelligent control validation by numerical simulations. The latter will be reported in a second part of the study.

  12. Conditional control in visual selection

    NARCIS (Netherlands)

    van Zoest, Wieske; Van der Stigchel, Stefan; Donk, Mieke

    2017-01-01

    Attention and eye movements provide a window into the selective processing of visual information. Evidence suggests that selection is influenced by various factors and is not always under the strategic control of the observer. The aims of this tutorial review are to give a brief introduction to eye

  13. Quality assurance in a cask fleet parts control system

    International Nuclear Information System (INIS)

    Fernandez, C.; Shappert, L.B.

    1992-01-01

    This paper discusses applicable portions of the eighteen Quality Assurance criteria of Subpart H, 10 CFR 71 which are incorporated into a relational data base system which has been designed to manage the spare parts control system for a fleet of spent nuclear fuel casks. The system includes not only parts in warehouse storage but parts in use in the field plus casks, ancillary equipment, test equipment, support devices, and even personnel. It provides a high degree of assurance that any device for which a condition for certification has expired will be flagged for recertification testing or removal from service well before the critical date

  14. Quality assurance in a cask fleet parts control system

    International Nuclear Information System (INIS)

    Fernandez, C.; McCreery, P.N.; Shappert, L.B.

    1991-01-01

    Applicable portions of the eighteen Quality Assurance criteria of Subpart H, 10 CFR 71 are incorporated into a relational data base system which has been designed to manage the spare parts control system for a fleet of spent nuclear fuel casks. The system includes not only parts in warehouse storage but parts in use in the field plus casks, ancillary equipment, test equipment, support devices, and even personnel. It provides a high degree of assurance that any device for which a condition for certification has expired will be flagged for recertification testing or removal from service well before the critical date

  15. Intelligent control of HVAC systems. Part II: perceptron performance analysis

    Directory of Open Access Journals (Sweden)

    Ioan URSU

    2013-09-01

    Full Text Available This is the second part of a paper on intelligent type control of Heating, Ventilating, and Air-Conditioning (HVAC systems. The whole study proposes a unified approach in the design of intelligent control for such systems, to ensure high energy efficiency and air quality improving. In the first part of the study it is considered as benchmark system a single thermal space HVAC system, for which it is assigned a mathematical model of the controlled system and a mathematical model(algorithm of intelligent control synthesis. The conception of the intelligent control is of switching type, between a simple neural network, a perceptron, which aims to decrease (optimize a cost index,and a fuzzy logic component, having supervisory antisaturating role for neuro-control. Based on numerical simulations, this Part II focuses on the analysis of system operation in the presence only ofthe neural control component. Working of the entire neuro-fuzzy system will be reported in a third part of the study.

  16. Trust Control of VTOL Aircraft Part Deux

    Science.gov (United States)

    Dugan, Daniel C.

    2014-01-01

    Thrust control of Vertical Takeoff and Landing (VTOL) aircraft has always been a debatable issue. In most cases, it comes down to the fundamental question of throttle versus collective. Some aircraft used throttle(s), with a fore and aft longitudinal motion, some had collectives, some have used Thrust Levers where the protocol is still "Up is Up and Down is Down," and some have incorporated both throttles and collectives when designers did not want to deal with the Human Factors issues. There have even been combinations of throttles that incorporated an arc that have been met with varying degrees of success. A previous review was made of nineteen designs without attempting to judge the merits of the controller. Included in this paper are twelve designs entered in competition for the 1961 Tri-Service VTOL transport. Entries were from a Bell/Lockheed tiltduct, a North American tiltwing, a Vanguard liftfan, and even a Sikorsky tiltwing. Additional designs were submitted from Boeing Wichita (direct lift), Ling-Temco-Vought with its XC-142 tiltwing, Boeing Vertol's tiltwing, Mcdonnell's compound and tiltwing, and the Douglas turboduct and turboprop designs. A private party submitted a re-design of the Breguet 941 as a VTOL transport. It is important to document these 53 year-old designs to preserve a part of this country's aviation heritage.

  17. Controlled cooling of an electronic system based on projected conditions

    Science.gov (United States)

    David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.

    2015-08-18

    Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.

  18. Connecting inventory control and repair shop control : a differentiated control structure for repairable spare parts

    NARCIS (Netherlands)

    Driessen, M.A.; Rustenburg, W.D.; Houtum, van G.J.J.A.N.; Wiers, V.C.S.

    2014-01-01

    This paper presents a control structure for integrating decisions on spare parts inventory control and the control of repair shops for maintenance spare parts. A dierentiated control structure is proposed for the various repair shop types recognized in practice. Decisions functions are mapped and

  19. Smart Sensors Enable Smart Air Conditioning Control

    Directory of Open Access Journals (Sweden)

    Chin-Chi Cheng

    2014-06-01

    Full Text Available In this study, mobile phones, wearable devices, temperature and human motion detectors are integrated as smart sensors for enabling smart air conditioning control. Smart sensors obtain feedback, especially occupants’ information, from mobile phones and wearable devices placed on human body. The information can be used to adjust air conditioners in advance according to humans’ intentions, in so-called intention causing control. Experimental results show that the indoor temperature can be controlled accurately with errors of less than ±0.1 °C. Rapid cool down can be achieved within 2 min to the optimized indoor capacity after occupants enter a room. It’s also noted that within two-hour operation the total compressor output of the smart air conditioner is 48.4% less than that of the one using On-Off control. The smart air conditioner with wearable devices could detect the human temperature and activity during sleep to determine the sleeping state and adjusting the sleeping function flexibly. The sleeping function optimized by the smart air conditioner with wearable devices could reduce the energy consumption up to 46.9% and keep the human health. The presented smart air conditioner could provide a comfortable environment and achieve the goals of energy conservation and environmental protection.

  20. Maintenance Centered Service Parts Inventory Control

    NARCIS (Netherlands)

    W.L. van Jaarsveld (Willem)

    2013-01-01

    textabstractHigh-tech capital goods enable the production of many services and articles that have become a part of our daily lives. Examples include the refineries that produce the gasoline we put in our cars, the photolithography systems that enable the production of the chips in our cell phones

  1. NECESSARY CONDITIONS OF STABILITY MOVING PARTS OF ROTOR CENTRIFUGE

    OpenAIRE

    Strackeljan, Jens; Babenko, Andriy; Lavrenko, Iaroslav

    2014-01-01

    Design features of modern centrifuges studied. Revealed that their rotors are movable elements that revolve around horizontal axes. The dynamics of these moving parts of laboratory centrifuge considered. Using the Lagrange equation of the second kind the resulting differential equations of their motion considered. The modeling visualization of motion using the software package RecurDyn was made. The results that obtained by the research package RecurDyn and analytically showed that their moti...

  2. Part of the job: the role of physical work conditions in the nurse turnover process.

    Science.gov (United States)

    Vardaman, James M; Cornell, Paul T; Allen, David G; Gondo, Maria B; Muslin, Ivan S; Mobley, Robin N; Brock, Meagan E; Sigmon, Tracy L

    2014-01-01

    Retention of nursing staff remains an important issue for health care managers. Turnover research has focused primarily on motivational and social factors as keys to retention, whereas the role of the physical work conditions has received considerably less attention. However, work design theory suggests that physical work conditions may be an important factor in fostering retention among nursing staff. The aim of this study was to integrate work design theory with turnover process models to explore the influence of perceptions of physical work conditions on the development of turnover intentions among nursing staff. Drawing on two samples of registered nurses working in cancer units in metropolitan hospitals in the southeastern United States, this study explores the impact of perceptions of physical work conditions on turnover intentions using ordinary least squares regression. Hypotheses are tested in Study 1 and replicated in Study 2. A measure of perceptions of physical work conditions is also developed and validated using exploratory (Study 1) and confirmatory (Study 2) factor analyses. Perceptions of physical work conditions explain variance in turnover intentions above than that explained by motivational and social factors. Specifically, employee perceptions of noisy work conditions are found to significantly increase turnover intentions, whereas perceptions that work conditions facilitate tasks were found to significantly reduce turnover intentions. Perceptions of temperature and health hazard did not show significant effects. Results suggest that health care managers and scholars should re-examine the role of physical work conditions in the turnover process. Investments in upgrades that facilitate tasks may foster retention better than investments that simply improve employee comfort. Negative perceptions of work conditions may have no impact if they are considered a normal "part of the job," although negative perceptions of conditions that are viewed as

  3. External access to ALICE controls conditions data

    International Nuclear Information System (INIS)

    Jadlovský, J; Jadlovská, A; Sarnovský, J; Jajčišin, Š; Čopík, M; Jadlovská, S; Papcun, P; Bielek, R; Čerkala, J; Kopčík, M; Chochula, P; Augustinus, A

    2014-01-01

    ALICE Controls data produced by commercial SCADA system WINCCOA is stored in ORACLE database on the private experiment network. The SCADA system allows for basic access and processing of the historical data. More advanced analysis requires tools like ROOT and needs therefore a separate access method to the archives. The present scenario expects that detector experts create simple WINCCOA scripts, which retrieves and stores data in a form usable for further studies. This relatively simple procedure generates a lot of administrative overhead – users have to request the data, experts needed to run the script, the results have to be exported outside of the experiment network. The new mechanism profits from database replica, which is running on the CERN campus network. Access to this database is not restricted and there is no risk of generating a heavy load affecting the operation of the experiment. The developed tools presented in this paper allow for access to this data. The users can use web-based tools to generate the requests, consisting of the data identifiers and period of time of interest. The administrators maintain full control over the data – an authorization and authentication mechanism helps to assign privileges to selected users and restrict access to certain groups of data. Advanced caching mechanism allows the user to profit from the presence of already processed data sets. This feature significantly reduces the time required for debugging as the retrieval of raw data can last tens of minutes. A highly configurable client allows for information retrieval bypassing the interactive interface. This method is for example used by ALICE Offline to extract operational conditions after a run is completed. Last but not least, the software can be easily adopted to any underlying database structure and is therefore not limited to WINCCOA.

  4. AISI/DOE Advanced Process Control Program Vol. 3 of 6: MICROSTRUCTURAL ENGINEERING IN HOT-STRIP MILLS Part 2 of 2: Constitutive Behavior Modeling of Steels Under Hot-Rolling Conditions; FINAL

    International Nuclear Information System (INIS)

    Yi-Wen Cheng; Patrick Purtscher

    1999-01-01

    This report describes the development of models for predicting (1) constitutive behaviors and (2) mechanical properties of hot-rolled steels as functions of chemical composition, microstructural features, and processing variables. The study includes the following eight steels: A36, DQSK, HSLA-V, HSLA-Nb, HSLA-50/Ti-Nb, and two interstitial-free (IF) grades. These developed models have been integrated into the Hot-Strip Mill Model (HSMM), which simulates the hot strip rolling mills and predicts the mechanical properties of hot-rolled products. The HSMM model has been developed by the University of British Columbia-Canada as a part of project on the microstructural engineering in hot-strip mills

  5. Diesel soot oxidation under controlled conditions

    OpenAIRE

    Song, Haiwen

    2003-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University, 11/12/2003. In order to improve understanding of diesel soot oxidation, an experimental rig was designed and set up, in which the soot oxidation conditions, such as temperature, oxygen partial pressure, and CO2 partial pressure, could be varied independently of each other. The oxidizing gas flow in the oxidizer was under laminar condition. This test rig comprised a naturally-aspirated single ...

  6. Model Development for Auto Spare Parts Inventory Control and ...

    African Journals Online (AJOL)

    2012-12-01

    Dec 1, 2012 ... essential motivating factors for providing control in manufacturing companies has never showed any sign ... The management of these parts can only be done with the aid of a computer; ... perform a discrete event simulation of.

  7. Inventory Control of Spare Parts for Operating Nuclear Power plants

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong-Hyuck; Jang, Se-Jin; Hwang, Eui-Youp; Yoo, Sung-Soo; Yoo, Keun-Bae; Lee, Sang-Guk; Hong, Sung-Yull [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    2006-07-01

    Inventory control of spare parts plays an increasingly important role in operation management. The trade-off is clear: on one hand a large number of spare parts ties up a large amount of capital, while on the other hand too little inventory may result in extremely costly emergency actions. This is why during the last few decades inventory of spare parts control has been the topics of many publications. Recently management systems such as manufacturing resources planning (MRP) and enterprise resource planning (ERP) have been added. However, most of these contributions have similar theoretical background. This means the concepts and techniques are mainly based on mathematical assumptions and modeling inventory of spare parts situations Nuclear utilities in Korea have several problems to manage the optimum level of spare parts though they used MRP System. Because most of items have long lead time and they are imported from United States, Canada, France and so on. In this paper, we will examine the available inventory optimization models which are applicable to nuclear power plant and then select optimum model and assumptions to make inventory of spare parts strategies. Then we develop the computer program to select and determine optimum level of spare parts which should be automatically controlled by KHNP ERP system. The main contribution of this paper is an inventory of spare parts control model development, which can be applied to nuclear power plants in Korea.

  8. Inventory Control of Spare Parts for Operating Nuclear Power plants

    International Nuclear Information System (INIS)

    Park, Jong-Hyuck; Jang, Se-Jin; Hwang, Eui-Youp; Yoo, Sung-Soo; Yoo, Keun-Bae; Lee, Sang-Guk; Hong, Sung-Yull

    2006-01-01

    Inventory control of spare parts plays an increasingly important role in operation management. The trade-off is clear: on one hand a large number of spare parts ties up a large amount of capital, while on the other hand too little inventory may result in extremely costly emergency actions. This is why during the last few decades inventory of spare parts control has been the topics of many publications. Recently management systems such as manufacturing resources planning (MRP) and enterprise resource planning (ERP) have been added. However, most of these contributions have similar theoretical background. This means the concepts and techniques are mainly based on mathematical assumptions and modeling inventory of spare parts situations Nuclear utilities in Korea have several problems to manage the optimum level of spare parts though they used MRP System. Because most of items have long lead time and they are imported from United States, Canada, France and so on. In this paper, we will examine the available inventory optimization models which are applicable to nuclear power plant and then select optimum model and assumptions to make inventory of spare parts strategies. Then we develop the computer program to select and determine optimum level of spare parts which should be automatically controlled by KHNP ERP system. The main contribution of this paper is an inventory of spare parts control model development, which can be applied to nuclear power plants in Korea

  9. Quality control of injection moulded micro mechanical parts

    DEFF Research Database (Denmark)

    Gasparin, Stefania; Tosello, Guido; Hansen, Hans Nørgaard

    2009-01-01

    Quality control of micro components is an increasing challenge. Smaller mechanical parts are characterized by smaller tolerance to be verified. This paper focuses on the dimensional verification of micro injection moulded components selected from an industrial application. These parts are measured...... using an Optical Coordinate Measuring Machine (OCMM), which guarantees fast surface scans suitable for in line quality control. The uncertainty assessment of the measurements is calculated following the substitution method. To investigate the influence parameters in optical coordinate metrology two...

  10. Contradictions of Control, Part 1: Administrators and Teachers.

    Science.gov (United States)

    McNeil, Linda M.

    1988-01-01

    Bureaucratic controls are at war with educational goals in our school system. This disharmony drastically affects the teacher/student relationship. The first in a three-part series, this article summarizes complex ethnographic data from the report "Contradictions of Control: School Structure and School Knowledge." Includes 6 references. (MD)

  11. Experimental determination of the energy efficiency of an air-cooled chiller under part load conditions

    International Nuclear Information System (INIS)

    Yu, F.W.; Chan, K.T.

    2005-01-01

    In cities located in a subtropical climate, air-cooled chillers are commonly used to provide cooling to the indoor environment. This accounts for the increasing electricity demand of buildings over the decades. This paper investigates how the condensing temperature serves to accurately determine the energy efficiency, or coefficient of performance (COP), of air-cooled chillers under part load conditions. An experiment on an air-cooled reciprocating chiller showed that for any given operating condition, the COP of the chiller varies, depending on how the condensing temperature is controlled. A sensitivity analysis is implemented to investigate to what extent COP is responding to changes in operating variables and confirms that the condensing temperature is an adequate variable to gauge COP under various operating conditions. The specifications of the upper limit for the condensing temperature in order to improve the energy efficiency of air-cooled chillers are discussed. The results of this work will give designers and researchers a good idea about how to model chiller energy performance curves in the thermal and energy computation exercises

  12. 42 CFR 482.42 - Condition of participation: Infection control.

    Science.gov (United States)

    2010-10-01

    ... Hospital Functions § 482.42 Condition of participation: Infection control. The hospital must provide a... be an active program for the prevention, control, and investigation of infections and communicable... 42 Public Health 5 2010-10-01 2010-10-01 false Condition of participation: Infection control. 482...

  13. Part-load pumping operation, control and behaviour

    International Nuclear Information System (INIS)

    1988-01-01

    Twenty one papers are printed. Their main concern is with pump performance under abnormal operating conditions or when operating at part-load. The effect of part-load operation on pump performance, pump internal flow and pump cavitation and noise were considered. The pumps considered are used in a variety of situations and some case studies were discussed. One paper about part-load operation of the boiler pumps for French pressurized water reactors and one paper on pressure pulsations of centrifugal pumps at very low flowrate, are indexed separately. (U.K.)

  14. Controlled Nonlinear Stochastic Delay Equations: Part I: Modeling and Approximations

    International Nuclear Information System (INIS)

    Kushner, Harold J.

    2012-01-01

    This two-part paper deals with “foundational” issues that have not been previously considered in the modeling and numerical optimization of nonlinear stochastic delay systems. There are new classes of models, such as those with nonlinear functions of several controls (such as products), each with is own delay, controlled random Poisson measure driving terms, admissions control with delayed retrials, and others. There are two basic and interconnected themes for these models. The first, dealt with in this part, concerns the definition of admissible control. The classical definition of an admissible control as a nonanticipative relaxed control is inadequate for these models and needs to be extended. This is needed for the convergence proofs of numerical approximations for optimal controls as well as to have a well-defined model. It is shown that the new classes of admissible controls do not enlarge the range of the value functions, is closed (together with the associated paths) under weak convergence, and is approximatable by ordinary controls. The second theme, dealt with in Part II, concerns transportation equation representations, and their role in the development of numerical algorithms with much reduced memory and computational requirements.

  15. Microcomputer control of a residential photovoltaic power conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Bose, B.K.; Steigerwald, R.L.; Szczesny, P.M.

    1984-01-01

    Microcomputer-based control of a residential photovoltaic power conditioning system is described. The microcomputer is responsible for array current feedback control, maximum power tracking control, array safe zone steering control, phase-locked reference wave synthesis, sequencing control, and some diagnostics. The control functions are implemented using Intel 8751 single-chip microcomputer-based hardware and software. The controller has been tested in the laboratory with the prototype power conditioner and shows excellent performance.

  16. Microcomputer control of a residential photovoltaic power conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Bose, B.K.; Steigerwald, R.L.; Szczesny, P.M.

    1985-09-01

    Microcomputer-based control of a residential photovoltaic power conditioning system is described. The microcomputer is responsible for array current feedback control, maximum power tracking control, array safe zone steering control, phase-locked reference wave synthesis, sequencing control, and some diagnostics. The control functions are implemented using Intel 8751 single-chip microcomputer-based hardware and software. The controller has been tested in the laboratory with the prototype power conditioner and shows excellent performance.

  17. Verification of the karst flow model under laboratory controlled conditions

    Science.gov (United States)

    Gotovac, Hrvoje; Andric, Ivo; Malenica, Luka; Srzic, Veljko

    2016-04-01

    Karst aquifers are very important groundwater resources around the world as well as in coastal part of Croatia. They consist of extremely complex structure defining by slow and laminar porous medium and small fissures and usually fast turbulent conduits/karst channels. Except simple lumped hydrological models that ignore high karst heterogeneity, full hydraulic (distributive) models have been developed exclusively by conventional finite element and finite volume elements considering complete karst heterogeneity structure that improves our understanding of complex processes in karst. Groundwater flow modeling in complex karst aquifers are faced by many difficulties such as a lack of heterogeneity knowledge (especially conduits), resolution of different spatial/temporal scales, connectivity between matrix and conduits, setting of appropriate boundary conditions and many others. Particular problem of karst flow modeling is verification of distributive models under real aquifer conditions due to lack of above-mentioned information. Therefore, we will show here possibility to verify karst flow models under the laboratory controlled conditions. Special 3-D karst flow model (5.6*2.6*2 m) consists of concrete construction, rainfall platform, 74 piezometers, 2 reservoirs and other supply equipment. Model is filled by fine sand (3-D porous matrix) and drainage plastic pipes (1-D conduits). This model enables knowledge of full heterogeneity structure including position of different sand layers as well as conduits location and geometry. Moreover, we know geometry of conduits perforation that enable analysis of interaction between matrix and conduits. In addition, pressure and precipitation distribution and discharge flow rates from both phases can be measured very accurately. These possibilities are not present in real sites what this model makes much more useful for karst flow modeling. Many experiments were performed under different controlled conditions such as different

  18. Evaluation of Antioxidant Activity from Different Plant Parts of Senduduk Herb: Extraction Conditions Optimization of Selected Plant Part

    Directory of Open Access Journals (Sweden)

    Kamaludin Nor Helya Iman

    2017-01-01

    Full Text Available This work reports a study on evaluation of antioxidant properties from flower of Senduduk herb. Natural occurring antioxidant was mostly preferred due to their little or no toxicity compared to the synthetic antioxidants which posses carcinogenic effects. Extraction was done on selected plant parts of Sendududk herb including leaves, stem, flower and berry parts to evaluate their antioxidant potentiality. Flower part of Sendudk herb extracted using acetonic solvent promotes highest antioxidant activity which is 93.97 ± 1.38 % as compared to leaves (92.20 ± 0.20 %, stem (47.94 ± 1.42% and berry (92.88 ± 0.63% using the same extracting solvent. Thus, Senduduk flower was chosen to be continued with screening and optimization process. Single factor experiment using the one factor at a time (OFAT method was done to study the effect of each extraction parameter that was solid to solvent ratio, temperature and solvent concentration. The extraction condition in each parametric study which results in highest antioxidant activity was used as the middle level of optimization process using Response Surface Methodology (RSM coupled with Central Composite Design (CCD. The optimum condition was at 1:20 solid to solvent ratio, 64.61°C temperature and 80.24% acetone concentration which result in antioxidant activity of 96.53%. The verification of RSM showed that the model used to predict the antioxidant activity was valid and adequate with the experimental parameters.

  19. Factors affecting sustainable animal trypanosomosis control in parts ...

    African Journals Online (AJOL)

    This study examined the factors affecting sustainable trypanosomiasis control in parts of Kaduna State within the sub-humid savannah ecological zone of Nigeria. Focus group discussions were ... More awareness and preference for pour-on and aerial spraying were higher than the use of traps, target or screens. Rearing of ...

  20. An Automatic Control System for Conditioning 30 GHz Accelerating Structures

    CERN Document Server

    Dubrovskiy, A

    2008-01-01

    A software application programme has been developed to allow fast and automatic high-gradient conditioning of accelerating structures at 30 GHz in CTF3. The specificity of the application is the ability to control the high-power electron beam which produces the 30 GHz RF power used to condition the accelerating structures. The programme permits operation round the clock with minimum manpower requirements. In this paper the fast control system, machine control system, logging system, graphical user control interface and logging data visualization are described. An outline of the conditioning control system itself and of the feedback controlling peak power and pulse length is given. The software allows different types of conditioning strategies to be programmed

  1. Using magnetic levitation for non-destructive quality control of plastic parts.

    Science.gov (United States)

    Hennek, Jonathan W; Nemiroski, Alex; Subramaniam, Anand Bala; Bwambok, David K; Yang, Dian; Harburg, Daniel V; Tricard, Simon; Ellerbee, Audrey K; Whitesides, George M

    2015-03-04

    Magnetic levitation (MagLev) enables rapid and non-destructive quality control of plastic parts. The feasibility of MagLev as a method to: i) rapidly assess injection-molded plastic parts for defects during process optimization, ii) monitor the degradation of plastics after exposure to harsh environmental conditions, and iii) detect counterfeit polymers by density is demonstrated. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Process and part filling control in micro injection molding

    DEFF Research Database (Denmark)

    Tosello, Guido; Hansen, Hans Nørgaard; Schoth, Andreas

    2008-01-01

    The influence of process parameters on μ-injection molding (μIM) and on μ-injection molded parts has been investigated using Design of Experiments. A mold with a sensor applied at injection location was used to monitor actual injection pressure and to determine the cavity filling time. Flow markers...... position was measured on the polymer μ-parts to evaluate filling behavior of the polymer melt flowing through μ-features. Experimental results obtained under different processing conditions were evaluated to correlate the process parameter levels influence on the selected responses. Results showed...... that the injection speed in one of the most influencing process parameters on the μIM process and on the μ-parts filling....

  3. Reliable Grid Condition Detection and Control of Single-Phase Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai

    standards addressed to the grid-connected systems will harmonize the combination of the DPGS and the classical power plants. Consequently, the major tasks of this thesis were to develop new grid condition detection techniques and intelligent control in order to allow the DPGS not only to deliver power...... to the utility grid but also to sustain it. This thesis was divided into two main parts, namely "Grid Condition Detection" and "Control of Single-Phase DPGS". In the first part, the main focus was on reliable Phase Locked Loop (PLL) techniques for monitoring the grid voltage and on grid impedance estimation...... techniques. Additionally, a new technique for detecting the islanding mode has been developed and successfully tested. In the second part, the main reported research was concentrated around adaptive current controllers based on the information provided by the grid condition detection techniques. To guarantee...

  4. Musculoskeletal disorders associated with HIV infection and AIDS. Part II: Non-infectious musculoskeletal conditions

    International Nuclear Information System (INIS)

    Tehranzadeh, Jamshid; Ter-Oganesyan, Ramon R.; Steinbach, Lynne S.

    2004-01-01

    This section of a two-part series on musculoskeletal disorders associated with HIV infection and AIDS reviews the non-infectious musculoskeletal conditions. In the first part, the infectious conditions were reviewed. The non-infectious conditions include polymyositis, drug-induced myopathy, myositis ossificans, adhesive capsulitis, avascular necrosis, bone marrow abnormalities, and hypertrophic osteoarthropathy. Inflammatory and reactive arthropathies are more prevalent in HIV-positive individuals, and a separate section is dedicated to these conditions, including Reiter's syndrome, psoriatic arthritis, HIV-associated arthritis, painful articular syndrome, and acute symmetric polyarthritis. Lastly, we include a discussion of HIV-related neoplastic processes that affect the musculoskeletal system, namely Kaposi's sarcoma and non-Hodgkin's lymphoma. (orig.)

  5. Musculoskeletal disorders associated with HIV infection and AIDS. Part II: Non-infectious musculoskeletal conditions

    Energy Technology Data Exchange (ETDEWEB)

    Tehranzadeh, Jamshid [Department of Radiological Sciences, University of California, Irvine, CA (United States); Department of Radiological Sciences, Orange, CA (United States); Ter-Oganesyan, Ramon R. [College of Medicine, University of California, Irvine, CA (United States); Steinbach, Lynne S. [Department of Radiological Sciences, University of California, San Francisco (United States)

    2004-06-01

    This section of a two-part series on musculoskeletal disorders associated with HIV infection and AIDS reviews the non-infectious musculoskeletal conditions. In the first part, the infectious conditions were reviewed. The non-infectious conditions include polymyositis, drug-induced myopathy, myositis ossificans, adhesive capsulitis, avascular necrosis, bone marrow abnormalities, and hypertrophic osteoarthropathy. Inflammatory and reactive arthropathies are more prevalent in HIV-positive individuals, and a separate section is dedicated to these conditions, including Reiter's syndrome, psoriatic arthritis, HIV-associated arthritis, painful articular syndrome, and acute symmetric polyarthritis. Lastly, we include a discussion of HIV-related neoplastic processes that affect the musculoskeletal system, namely Kaposi's sarcoma and non-Hodgkin's lymphoma. (orig.)

  6. Adaptive neural network motion control for aircraft under uncertainty conditions

    Science.gov (United States)

    Efremov, A. V.; Tiaglik, M. S.; Tiumentsev, Yu V.

    2018-02-01

    We need to provide motion control of modern and advanced aircraft under diverse uncertainty conditions. This problem can be solved by using adaptive control laws. We carry out an analysis of the capabilities of these laws for such adaptive systems as MRAC (Model Reference Adaptive Control) and MPC (Model Predictive Control). In the case of a nonlinear control object, the most efficient solution to the adaptive control problem is the use of neural network technologies. These technologies are suitable for the development of both a control object model and a control law for the object. The approximate nature of the ANN model was taken into account by introducing additional compensating feedback into the control system. The capabilities of adaptive control laws under uncertainty in the source data are considered. We also conduct simulations to assess the contribution of adaptivity to the behavior of the system.

  7. Distributed automatic control of technological processes in conditions of weightlessness

    Science.gov (United States)

    Kukhtenko, A. I.; Merkulov, V. I.; Samoylenko, Y. I.; Ladikov-Royev, Y. P.

    1986-01-01

    Some problems associated with the automatic control of liquid metal and plasma systems under conditions of weightlessness are examined, with particular reference to the problem of stability of liquid equilibrium configurations. The theoretical fundamentals of automatic control of processes in electrically conducting continuous media are outlined, and means of using electromagnetic fields for simulating technological processes in a space environment are discussed.

  8. Developed adaptive neuro-fuzzy algorithm to control air conditioning ...

    African Journals Online (AJOL)

    The paper developed artificial intelligence technique adaptive neuro-fuzzy controller for air conditioning systems at different pressures. The first order Sugeno fuzzy inference system was implemented and utilized for modeling and controller design. In addition, the estimation of the heat transfer rate and water mass flow rate ...

  9. Preliminary study of S-CO{sub 2} cycle control logic for part load operation

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Yoonhan; Lee, Jeong Ik [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2016-05-15

    The benefits of S-CO{sub 2} cycle are relatively high efficiency under the mild turbine inlet temperature region, simple layout configuration and small foot-print. In addition, the safety of the SFR system can be inherently enhanced as the violent sodium-water reaction can be substituted with the mild sodium-CO{sub 2} reaction. 75MWe S-CO{sub 2} recompression cycle with radial type turbomachineries and PCHE was designed. Under various part load conditions (30-100% thermal load), off-design performance of the designed system was assessed, and different control logics were first tested. It was identified that the inventory control strategy is the most efficient logic for the part load operation. In the system operation, the compressor surge condition is seriously considered and controlled to avoid the system damage.

  10. Controlling Precision Stepper Motors in Flight Using (Almost) No Parts

    Science.gov (United States)

    Randall, David

    2010-01-01

    This concept allows control of high-performance stepper motors with minimal parts count and minimal flight software complexity. Although it uses a small number of common flight-qualified parts and simple control algorithms, it is capable enough to meet demanding system requirements. Its programmable nature makes it trivial to implement changes to control algorithms both during integration & test and in flight. Enhancements such as microstepping, half stepping, back-emf compensation, and jitter reduction can be tailored to the requirements of a large variety of stepper motor based applications including filter wheels, focus mechanisms, antenna tracking subsystems, pointing and mobility. The hardware design (using an H-bridge motor controller IC) was adapted from JPL's MER mission, still operating on Mars. This concept has been fully developed and incorporated into the MCS instrument on MRO, currently operating in Mars orbit. It has been incorporated into the filter wheel mechanism and linear stage (focus) mechanism for the AMT instrument. On MCS/MRO, two of these circuits control the elevation and azimuth of the MCS telescope/radiometer assembly, allowing the instrument to continuously monitor the limb of the Martian atmosphere. Implementation on MCS/MRO resulted in a 4:1 reduction in the volume and mass required for the motor driver electronics (100:25 square inches of PCB space), producing a very compact instrument. In fact, all of the electronics for the MCS instrument are packaged within the movable instrument structure. It also saved approximately 3 Watts of power. Most importantly, the design enabled MCS to meet very its stringent maximum allowable torque disturbance requirements.

  11. MINIMIZING GLOVEBOX GLOVE BREACHES, PART IV: CONTROL CHARTS

    International Nuclear Information System (INIS)

    Cournoyer, Michael E.; Lee, Michelle B.; Schreiber, Stephen B.

    2007-01-01

    At the Los Alamos National Laboratory (LANL) Plutonium Facility, plutonium. isotopes and other actinides are handled in a glovebox environment. The spread of radiological contamination, and excursions of contaminants into the worker's breathing zone, are minimized and/or prevented through the use of glovebox technology. Evaluating the glovebox configuration, the glovebo gloves are the most vulnerable part of this engineering control. Recognizing this vulnerability, the Glovebox Glove Integrity Program (GGIP) was developed to minimize and/or prevent unplanned openings in the glovebox environment, i.e., glove failures and breaches. In addition, LANL implement the 'Lean Six Sigma (LSS)' program that incorporates the practices of Lean Manufacturing and Six Sigma technologies and tools to effectively improve administrative and engineering controls and work processes. One tool used in LSS is the use of control charts, which is an effective way to characterize data collected from unplanned openings in the glovebox environment. The benefit management receives from using this tool is two-fold. First, control charts signal the absence or presence of systematic variations that result in process instability, in relation to glovebox glove breaches and failures. Second, these graphical representations of process variation detennine whether an improved process is under control. Further, control charts are used to identify statistically significant variations (trends) that can be used in decision making to improve processes. This paper discusses performance indicators assessed by the use control charts, provides examples of control charts, and shows how managers use the results to make decisions. This effort contributes to LANL Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations.

  12. Critical spare parts ordering decisions using conditional reliability and stochastic lead time

    International Nuclear Information System (INIS)

    Godoy, David R.; Pascual, Rodrigo; Knights, Peter

    2013-01-01

    Asset-intensive companies face great pressure to reduce operation costs and increase utilization. This scenario often leads to over-stress on critical equipment and its spare parts associated, affecting availability, reliability, and system performance. As these resources impact considerably on financial and operational structures, the opportunity is given by demand for decision-making methods for the management of spare parts processes. We proposed an ordering decision-aid technique which uses a measurement of spare performance, based on the stress–strength interference theory; which we have called Condition-Based Service Level (CBSL). We focus on Condition Managed Critical Spares (CMS), namely, spares which are expensive, highly reliable, with higher lead times, and are not available in store. As a mitigation measure, CMS are under condition monitoring. The aim of the paper is orienting the decision time for CMS ordering or just continuing the operation. The paper presents a graphic technique which considers a rule for decision based on both condition-based reliability function and a stochastic/fixed lead time. For the stochastic lead time case, results show that technique is effective to determine the time when the system operation is reliable and can withstand the lead time variability, satisfying a desired service level. Additionally, for the constant lead time case, the technique helps to define insurance spares. In conclusion, presented ordering decision rule is useful to asset managers for enhancing the operational continuity affected by spare parts

  13. Measuring Effectiveness of Persuasive Games Using an Informative Control Condition

    Directory of Open Access Journals (Sweden)

    Mara Soekarjo

    2015-06-01

    Full Text Available Research about the effectiveness of persuasive games is still emerging. This article presents a literature review of studies that empirically evaluate the effectiveness of persuasive games. The review concluded that limited empirical evidence is currently available to prove their effectiveness in attitude change. It further revealed that almost no study employed an informative control condition, making it difficult to conclude that the game was more effective than a control condition. Next, in a pretest-posttest design an empirical study tested whether change in attitude was different for people playing the persuasive game "EnerCities" compared to a control condition where participants read a document with highly similar information. No significant differences in increase of attitude or knowledge between participants that played the game and participants in the informative control condition were found. Based on the results of the literature review and the empirical study presented, it hence cannot be concluded that playing a game leads to a greater change in attitude or knowledge acquisition than experiencing conventional media would. Future work should employ designs with proper control conditions and focus on which game features lead to significant effects.

  14. A survey on control schemes for distributed solar collector fields. Part II: Advanced control approaches

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, E.F.; Rubio, F.R. [Universidad de Sevilla, Escuela Superior de Ingenieros, Departamento de Ingenieria de Sistemas y Automatica, Camino de Los Descubrimientos s/n, E-41092 Sevilla (Spain); Berenguel, M. [Universidad de Almeria, Departamento de Lenguajes y Computacion, Area de Ingenieria de Sistemas y Automatica, Carretera Sacramento s/n, E-04120 La Canada, Almeria (Spain); Valenzuela, L. [Plataforma Solar de Almeria - CIEMAT, Carretera Senes s/n, P.O. Box 22, E-04200 Tabernas (Almeria) (Spain)

    2007-10-15

    This article presents a survey of the different advanced automatic control techniques that have been applied to control the outlet temperature of solar plants with distributed collectors during the last 25 years. A classification of the modeling and control approaches described in the first part of this survey is used to explain the main features of each strategy. The treated strategies range from classical advanced control strategies to those with few industrial applications. (author)

  15. Meteorological conditions of the mudflow origin in the northern part of the French Alps

    Directory of Open Access Journals (Sweden)

    L. O. Pavlova

    2012-01-01

    Full Text Available A mudflow phenomena are at the top of the list of dangerous natural hazards in the mountains areas all over the world. Among factors resulting in a mudflow phenomena triggering, meteorological conditions are considered to be the most relevant. The general objective of this study was to identify meteorological parameters controlling the triggering of mudflow phenomena in one part of the French Alps over the last 40 years. Major factors are quite well explored at the global scale or contrariwise in very precise territory in particular catchment areas. However, for now we have a poor knowledge of those factors at the scale of a medium-sized region (including catchments with different geomorphic characteristics over several km² especially in the French Alps. In addition, in this region only a few studies focused on relationships with climate. To understand mudflow phenomena activity and their link with meteorological parameters in the north region of the French Alps, we used a multivariate statistical approach. Regional meteorological parameters (such as mean monthly temperature and precipitation were first computed from a Principal Component Analysis of observed meteorological data from four weather stations. A binomial monthly logistic regression probability model was then fitted between the main principal components and mudflow phenomena data base composed of 298 debris flow events triggered between 1971 and 2008. Results revealed that the most successful model including two meteorological predictors (minimal monthly temperature and the number of rainy days between May and September correctly explains more than 60% of the mudflow phenomena events.

  16. Iron ore sintering. Part 3: Automatic and control systems

    Directory of Open Access Journals (Sweden)

    Alejandro Cores

    2015-01-01

    Full Text Available El proceso de sinterización implica un gran número de parámetros, más de quinientos, cada uno de los cuales ejerce una mayor o menor influencia y necesita ser controlado, dentro de los límites posibles, con el fin de optimizar la productividad, la estabilidad del proceso, y la composición y la calidad de la sinterizado producido. Para cumplir con la legislación ambiental, un sistema de control de la contaminación debe monitorizar la composición de las partículas y los gases generados en la planta de sinterización y emitidos a la atmósfera. Los sistemas de automatización y control son herramientas vitales para ayudar a los operadores de la planta en el seguimiento de cada etapa del proceso de producción de sinterizado.

  17. Slag Behavior in Gasifiers. Part I: Influence of Coal Properties and Gasification Conditions

    Directory of Open Access Journals (Sweden)

    Ping Wang

    2013-02-01

    Full Text Available In the entrained-flow gasifiers used in integrated gasification combined cycle (IGCC plants, the majority of mineral matter transforms to liquid slag on the wall of the gasifier and flows out the bottom. However, a small fraction of the mineral matter is entrained (as fly ash with the raw syngas out of the gasifier to downstream processing. This molten/sticky fly ash could cause fouling of the syngas cooler. To improve gasification availability through better design and operation of the gasification process, a better understanding of slag behavior and the characteristics of the slagging process is needed. Char/ash properties, gas compositions in the gasifier, the gasifier wall structure, fluid dynamics, and plant operating conditions (mainly temperature and oxygen/carbon ratio all affect slagging behavior. Because coal has varying ash content and composition, different operating conditions are required to maintain the slag flow and limit problems downstream. In Part I, we review the main types and the operating conditions of entrained-flow gasifiers and coal properties used in IGCC plants; we identify and discuss the key coal ash properties and the operating conditions impacting slag behavior; finally, we summarize the coal quality criteria and the operating conditions in entrained-flow gasifiers. In Part II, we discuss the constitutive modeling related to the rheological studies of slag flow.

  18. Overview of impurity control and wall conditioning in NSTX

    International Nuclear Information System (INIS)

    Kugel, H.W.; Maingi, R.; Wampler, W.; Barry, R.E.; Bell, M.; Blanchard, W.; Gates, D.; Johnson, D.; Kaita, R.; Kaye, S.; Maqueda, R.; Menard, J.; Menon, M.M.; Mueller, D.; Ono, M.; Paul, S.; Peng, Y-K.M.; Raman, R.; Roquemore, A.; Skinner, C. H.; Sabbagh, S.; Stratton, B.; Stutman, D.; Wilson, J. R.; Zweben, S.

    2000-01-01

    The National Spherical Torus Experiment (NSTX) started plasma operations i n February 1999. In the first extended period of experiments, NSTX achieved high current, inner wall limited, double null, and single null plasma discharges, initial Coaxial Helicity Injection, and High Harmonic Fast Wave results. As expected, discharge reproducibility and performance were strongly affected by wall conditions. In this paper, the authors describe the internal geometry, and initial plasma discharge, impurity control, wall conditioning, erosion, and deposition results

  19. Control Strategy for Microgrid Inverter under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Liu, Wenzhao; Zhang, X.

    2014-01-01

    This paper presents the theoretical analysis of the inherent reason of current harmonic and power oscillation phenomena in case of operating the microgrid inverter under unbalanced grid voltage conditions. In order to flexibly control the current harmonic and power oscillation, a new stationary...... inverter. Finally, the performance evaluation tests are carried out under unbalanced grid voltage conditions. Results verify the effectiveness of the propose method....

  20. A safety control device for detecting undesirable conditions

    Energy Technology Data Exchange (ETDEWEB)

    1974-09-26

    The invention relates to safety control devices. It deals with a device adapted to transmit a warning signal and to the detection of an undesirable condition in an associated apparatus, said device comprising switching means comprising transistors mounted in a reaction path, feeding means for opening the switching means whenever an undesirable condition has been detected by sensors, whereby an oscillator is caused to stop oscillating, and an outlet device controlled by the oscillator stoppage. This can be applied to the supervision of nuclear reactor.

  1. Electronic Control Of Small Hydro-Generators Part 1

    International Nuclear Information System (INIS)

    Perez G, Alvaro; Romero A, Carlos E.

    1993-01-01

    This work is the beginning of several applied itineraries, to the government of micro-centrals, mainly directed to the control of electric variables of the generator with the desire of obtaining a system of electric generation to drop it climbs, economic, reliable and with great sense of use of the hydraulic resources guided to poor communities, isolated of the system of national interconnection. In all hydroelectric power station without caring their capacity is fundamental to govern the speed of the system turbine generator, to guarantee a constant frequency of 60 Hz, the stability of this parameter is a measure of the quality of the energy given to the user. The used regulation method is the mechanical governor, its action it is to control the flow of water that it enters to the turbine. For small generation power stations (smaller to 200 Kw), the mechanical governor's cost is comparable to the total cost of the plant, then it is economic to use an electronic load control. The project develops the load control whose function is to add external electric load to the generator to maintain the constant nominal active power and similar to the power nominal mechanics surrendered by the turbine. The microprocessor 8088 dedicated to the control of the system by the complexity of the process, the quantity of variables and the precision in the answer of the system is used. To carry out the investigation project a simulation program it was designed in computer that allows to know the answer of the load control ahead of time for different conditions of the user's operation. These results were answered with the obtained experimental values of the final tests of the team, throwing very near values to those calculated

  2. Causal Factors and Adverse Conditions of Aviation Accidents and Incidents Related to Integrated Resilient Aircraft Control

    Science.gov (United States)

    Reveley, Mary S.; Briggs, Jeffrey L.; Evans, Joni K.; Sandifer, Carl E.; Jones, Sharon Monica

    2010-01-01

    The causal factors of accidents from the National Transportation Safety Board (NTSB) database and incidents from the Federal Aviation Administration (FAA) database associated with loss of control (LOC) were examined for four types of operations (i.e., Federal Aviation Regulation Part 121, Part 135 Scheduled, Part 135 Nonscheduled, and Part 91) for the years 1988 to 2004. In-flight LOC is a serious aviation problem. Well over half of the LOC accidents included at least one fatality (80 percent in Part 121), and roughly half of all aviation fatalities in the studied time period occurred in conjunction with LOC. An adverse events table was updated to provide focus to the technology validation strategy of the Integrated Resilient Aircraft Control (IRAC) Project. The table contains three types of adverse conditions: failure, damage, and upset. Thirteen different adverse condition subtypes were gleaned from the Aviation Safety Reporting System (ASRS), the FAA Accident and Incident database, and the NTSB database. The severity and frequency of the damage conditions, initial test conditions, and milestones references are also provided.

  3. Developed adaptive neuro-fuzzy algorithm to control air conditioning ...

    African Journals Online (AJOL)

    user

    ... conditioning system is highly appreciated and essential in most of our daily life. ... (Hossien and Karla, 2012) presented an overview work which provides an .... energy balance for SSSF and the mass flow balance for the water in the air are ..... of Automatic Control and Electrical Engineering at Siegen University, Germany.

  4. [Scientific reductionism and social control of mind. Part II].

    Science.gov (United States)

    Viniegra Velázquez, Leonardo

    In the second part of this essay, the progressive subordination of scientific endeavor and knowledge of business and profit is pointed out. For instance, the way facts are prioritized over concepts and ideas in scientific knowledge can translate into technological innovation, central to enterprise competitiveness and key to social mechanisms of control (military, cybernetic, ideological). Overcoming the scientific reductionism approach indicates recognizing the need to define progress in another way, one that infuses scientific knowledge with real liberating and inquisitive power. Power is essential in the search for a more collaborative, inclusive and pluralistic society where respect for human dignity and care for the ecosystem that we live in are prioritized. Copyright © 2014 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  5. Additive Manufacturing: Multi Material Processing and Part Quality Control

    DEFF Research Database (Denmark)

    Pedersen, David Bue

    This Ph.D dissertation,ffAdditive Manufacturing: Multi Material Processing and Part Quality Controlff, deal with Additive Manufacturing technologies which is a common name for a series of processes that are recognized by being computer controlled, highly automated, and manufacture objects...... by a layered deposition of material. Two areas of particular interest is addressed. They are rooted in two very different areas, yet is intended to fuel the same goal. To help Additive Manufacturing technologies one step closer to becoming the autonomous, digital manufacturing method of tomorrow. Vision...... systems A paradox exist in the field of Additive Manufacturing. The technologies allow for close-to unrestrained and integral geometrical freedom. Almost any geometry can be manufactured fast, e"ciently and cheap. Something that has been missing fundamental capability since the entering of the industrial...

  6. Musculoskeletal disorders associated with HIV infection and AIDS. Part I: Infectious musculoskeletal conditions

    International Nuclear Information System (INIS)

    Tehranzadeh, Jamshid; Ter-Oganesyan, Ramon R.; Steinbach, Lynne S.

    2004-01-01

    The musculoskeletal system can be affected by a variety of abnormalities in association with human immunodeficiency virus (HIV) infection. Although not as common as complications involving other organ systems, such as the pulmonary and the central nervous systems, HIV-associated musculoskeletal disorders are sometimes the initial presentation of the viral illness. Knowledge of the existence and the characteristic appearance of the conditions affecting bone, joint, and muscle in HIV-infected patients is valuable to radiologists for diagnosis and to clinicians for detection and appropriate treatment. We reviewed recent literature to provide a comprehensive assessment of the HIV-associated musculoskeletal disorders, and present radiologic examples from our own collection. This article is divided into two parts. In the first part we review the infectious musculoskeletal disorders associated with HIV illness and AIDS, including cellulitis, abscesses, pyomyositis, septic bursitis, septic arthritis, osteomyelitis, and bacillary angiomatosis. We also present a comprehensive spectrum of mycobacterial infections, consisting of tuberculous spondylitis and spondylodiskitis, arthritis, osteomyelitis, and tenosynovitis, as well as infections caused by atypical mycobacteria. Part II of this review will concentrate on non-infectious musculoskeletal conditions, including rheumatic disorders and neoplasms. (orig.)

  7. Musculoskeletal disorders associated with HIV infection and AIDS. Part I: Infectious musculoskeletal conditions

    Energy Technology Data Exchange (ETDEWEB)

    Tehranzadeh, Jamshid [Department of Radiological Sciences, University of California, Irvine, Irvine, California (United States); Department of Radiological Sciences, Rt. 140, 101 The City Drive ZC 5005, CA 92868-3298, Orange (United States); Ter-Oganesyan, Ramon R. [College of Medicine, University of California, Irvine, Irvine, California (United States); Steinbach, Lynne S. [Department of Radiological Sciences, University of California, San Francisco, San Francisco, California (United States)

    2004-05-01

    The musculoskeletal system can be affected by a variety of abnormalities in association with human immunodeficiency virus (HIV) infection. Although not as common as complications involving other organ systems, such as the pulmonary and the central nervous systems, HIV-associated musculoskeletal disorders are sometimes the initial presentation of the viral illness. Knowledge of the existence and the characteristic appearance of the conditions affecting bone, joint, and muscle in HIV-infected patients is valuable to radiologists for diagnosis and to clinicians for detection and appropriate treatment. We reviewed recent literature to provide a comprehensive assessment of the HIV-associated musculoskeletal disorders, and present radiologic examples from our own collection. This article is divided into two parts. In the first part we review the infectious musculoskeletal disorders associated with HIV illness and AIDS, including cellulitis, abscesses, pyomyositis, septic bursitis, septic arthritis, osteomyelitis, and bacillary angiomatosis. We also present a comprehensive spectrum of mycobacterial infections, consisting of tuberculous spondylitis and spondylodiskitis, arthritis, osteomyelitis, and tenosynovitis, as well as infections caused by atypical mycobacteria. Part II of this review will concentrate on non-infectious musculoskeletal conditions, including rheumatic disorders and neoplasms. (orig.)

  8. LHC Beam Dump Design Study - Part III : Off-normal operating conditions

    CERN Document Server

    Bruno, L; Ross, M; Sala, P

    2000-01-01

    The LHC beam dump design study has been preliminarily substantiated by energy deposition simulations (Part I) and heat transfer analyses (Part II). The present report is devoted to the abnormal operating conditions induced by a malfunction of the beam diluters. A general approach to the analysis of off-normal operation is presented, which is derived from standard design norms adopted in the nuclear industry. Attention is focused mainly on the carbon core, which is longitudinally split into segments of different density in order to better distribute the deposited energy. The maximum energy density it absorbs decreases by at least 33%, compared to a uniform standard density carbon core. This structure may sustain any partial sweep failure without major damage, up to the ultimate beam intensity and energy. To minimise the risks inherent in a fully unswept beam, a sacrificial graphite mandrel will be placed on the core axis, surrounded by a thick high strength carbon-carbon composite tube. With this arrangement, ...

  9. Modelling geothermal conditions in part of the Szczecin Trough - the Chociwel area

    Science.gov (United States)

    Miecznik, Maciej; Sowiżdżał, Anna; Tomaszewska, Barbara; Pająk, Leszek

    2015-09-01

    The Chociwel region is part of the Szczecin Trough and constitutes the northeastern segment of the extended Szczecin-Gorzów Synclinorium. Lower Jurassic reservoirs of high permeability of up to 1145 mD can discharge geothermal waters with a rate exceeding 250 m3/h and temperatures reach over 90°C in the lowermost part of the reservoirs. These conditions provide an opportunity to generate electricity from heat accumulated in geothermal waters using binary ORC (Organic Rankine Cycle) systems. A numerical model of the natural state and exploitation conditions was created for the Chociwel area with the use of TOUGH2 geothermal simulator (i.e., integral finite-difference method). An analysis of geological and hydrogeothermal data indicates that the best conditions are found to the southeast of the town of Chociwel, where the bottom part of the reservoir reaches 3 km below ground. This would require drilling two new wells, namely one production and one injection. Simulated production with a flow rate of 275 m3/h, a temperature of 89°C at the wellhead, 30°C injection temperature and wells being 1.2 km separated from each other leads to a small temperature drop and moderate requirements for pumping power over a 50 years' time span. The ORC binary system can produce at maximum 592.5 kW gross power with the R227ea found as the most suitable working fluid. Geothermal brine leaving the ORC system with a temperature c. 53°C can be used for other purposes, namely mushroom growing, balneology, swimming pools, soil warming, de-icing, fish farming and for heat pumps.

  10. Modelling geothermal conditions in part of the Szczecin Trough – the Chociwel area

    Directory of Open Access Journals (Sweden)

    Miecznik Maciej

    2015-09-01

    Full Text Available The Chociwel region is part of the Szczecin Trough and constitutes the northeastern segment of the extended Szczecin-Gorzów Synclinorium. Lower Jurassic reservoirs of high permeability of up to 1145 mD can discharge geothermal waters with a rate exceeding 250 m3/h and temperatures reach over 90°C in the lowermost part of the reservoirs. These conditions provide an opportunity to generate electricity from heat accumulated in geothermal waters using binary ORC (Organic Rankine Cycle systems. A numerical model of the natural state and exploitation conditions was created for the Chociwel area with the use of TOUGH2 geothermal simulator (i.e., integral finite-difference method. An analysis of geological and hydrogeothermal data indicates that the best conditions are found to the southeast of the town of Chociwel, where the bottom part of the reservoir reaches 3 km below ground. This would require drilling two new wells, namely one production and one injection. Simulated production with a flow rate of 275 m3/h, a temperature of 89°C at the wellhead, 30°C injection temperature and wells being 1.2 km separated from each other leads to a small temperature drop and moderate requirements for pumping power over a 50 years’ time span. The ORC binary system can produce at maximum 592.5 kW gross power with the R227ea found as the most suitable working fluid. Geothermal brine leaving the ORC system with a temperature c. 53°C can be used for other purposes, namely mushroom growing, balneology, swimming pools, soil warming, de-icing, fish farming and for heat pumps.

  11. Development of Fuzzy Logic Control for Vehicle Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Henry Nasution

    2008-08-01

    Full Text Available A vehicle air conditioning system is experimentally investigated. Measurements were taken during the experimental period at a time interval of one minute for a set point temperature of 22, 23 and 24oC with internal heat loads of 0, 1 and 2 kW. The cabin temperature and the speed of the compressor were varied and the performance of the system, energy consumption and energy saving ware analyzed. The main objective of the experimental work is to evaluate the energy saving obtained when the fuzzy logic control (FLC algorithm, through an inverter, continuously regulates the compressor speed. It demonstrates better control of the compressor operation in terms of energy consumption as compared to the control by using a thermostat imposing On/Off cycles on the compressor at the nominal frequency of 50 Hz. The experimental set-up consists of original components from the air conditioning system of a compact passenger vehicle. The experimental results indicate that the proposed technique can save energy and improve indoor comfort significantly for vehicle air conditioning systems compared to the conventional (On/Off control technique.

  12. Power systems control complex optimization in the new market conditions

    International Nuclear Information System (INIS)

    Krumm, L.; Kurrel, U.; Tauts, A.; Terno, O.; Zeidmanis, I.; Krisans, Z.

    2000-01-01

    A generalization and development of the theory and methods for complex optimisation of the performance and development control of an interconnected system (IPS) under new market conditions (mainly multicriterial and game approaches) is given considering the specifics of IPS at the international level in post-socialist countries and in particular in the Baltic states. Thereby the kernel of the mathematical apparatus of this theory the Generalized Reduced Gradient Method (GRGM) is further generalised and developed with the application of multicriterial and game methods to meet various market conditions. (author)

  13. Computation of reactor control rod drop time under accident conditions

    International Nuclear Information System (INIS)

    Dou Yikang; Yao Weida; Yang Renan; Jiang Nanyan

    1998-01-01

    The computational method of reactor control rod drop time under accident conditions lies mainly in establishing forced vibration equations for the components under action of outside forces on control rod driven line and motion equation for the control rod moving in vertical direction. The above two kinds of equations are connected by considering the impact effects between control rod and its outside components. Finite difference method is adopted to make discretization of the vibration equations and Wilson-θ method is applied to deal with the time history problem. The non-linearity caused by impact is iteratively treated with modified Newton method. Some experimental results are used to validate the validity and reliability of the computational method. Theoretical and experimental testing problems show that the computer program based on the computational method is applicable and reliable. The program can act as an effective tool of design by analysis and safety analysis for the relevant components

  14. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  15. Reactive gas control of non-stable plasma conditions

    International Nuclear Information System (INIS)

    Bellido-Gonzalez, V.; Daniel, B.; Counsell, J.; Monaghan, D.

    2006-01-01

    Most industrial plasma processes are dependant upon the control of plasma properties for repeatable and reliable production. The speed of production and range of properties achieved depend on the degree of control. Process control involves all the aspects of the vacuum equipment, substrate preparation, plasma source condition, power supplies, process drift, valves (inputs/outputs), signal and data processing and the user's understanding and ability. In many cases, some of the processes which involve the manufacturing of interesting coating structures, require a precise control of the process in a reactive environment [S.J. Nadel, P. Greene, 'High rate sputtering technology for throughput and quality', International Glass Review, Issue 3, 2001, p. 45. ]. Commonly in these circumstances the plasma is not stable if all the inputs and outputs of the system were to remain constant. The ideal situation is to move a process from set-point A to B in zero time and maintain the monitored signal with a fluctuation equal to zero. In a 'real' process that's not possible but improvements in the time response and energy delivery could be achieved with an appropriate algorithm structure. In this paper an advanced multichannel reactive plasma gas control system is presented. The new controller offers both high-speed gas control combined with a very flexible control structure. The controller uses plasma emission monitoring, target voltage or any process sensor monitoring as the input into a high-speed control algorithm for gas input. The control algorithm and parameters can be tuned to different process requirements in order to optimize response times

  16. Part load performance of air-cooled centrifugal chillers with variable speed condenser fan control

    Energy Technology Data Exchange (ETDEWEB)

    Yu, F.W.; Chan, K.T. [Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong (China)

    2007-11-15

    Air-cooled centrifugal chillers are commonly used in commercial buildings but their performance analysis is lacking. This paper investigates the part load performance of the chillers via a thermodynamic model. The model was validated using a wide range of operating data from an existing chiller with specific settings of outdoor temperature and condensing pressure in controlling the condensing temperature. The validated model was developed specifically to ascertain the maximum coefficient of performance of chiller (COP) together with the strategy for optimizing the condensing temperature under various operating conditions. It is found that the highest COP occurs at a part load ratio (PLR) of 0.71-0.84, depending on the outdoor temperature and the control of condensing temperature, rather than at full load. Yet the chillers operating at such part load conditions will cause extra energy used for the early staging of chilled water pumps. To minimize the overall chiller plant energy consumption, it is still preferable to implement chiller sequencing based on the full load condition than on the aforementioned PLRs. The results of this paper present criteria for implementing low-energy strategies for operating air-cooled chillers satisfying a given building cooling load profile. (author)

  17. Control in chronic condition self-care management

    DEFF Research Database (Denmark)

    Lawn, Sharon; Delany, Toni; Sweet, Linda

    2014-01-01

    of their communication style and the power of their role must improve for client chronic condition self-care management to be achieved. Training on the impacts of control in worker communication and systems where they work must be provided if unbeneficial forms of client dependency are to be overcome and true self......Aim: To examine health worker-client interactions during care planning to understand processes that foster client empowerment and disempowerment. Background: It is unclear how health worker-client exchanges and information sharing through chronic condition care planning currently operate in primary...... health care. Moreover, it is unclear how control in these exchanges either enhances collaborative decision-making, partnership and client empowerment, or works to create client disempowerment and dependency on workers and health services. Design: Critical discourse analysis of qualitative data from...

  18. Controlled damping of a physical pendulum: experiments near critical conditions

    International Nuclear Information System (INIS)

    Gonzalez, Manuel I; Bol, Alfredo

    2006-01-01

    This paper presents an experimental device for the study of damped oscillatory motion along with three associated experiments. Special emphasis is given on both didactic aspects and the interactivity of the experimental set-up, in order to assist students in understanding fundamental aspects of damped oscillatory motion and allow them to directly compare their experimental results with the well-known theory they can find in textbooks. With this in mind, a physical pendulum was selected with an eddy-current damping system that allows the damping conditions to be controlled with great precision. The three experiments examine accurate control of damping, frequency shift near critical damping and the transition from underdamped to overdamped conditions

  19. FINANCIAL AUDIT AS A PART OF STATE ADMINISTRATION IN UKRAINE: CONDITION AND PUBLIC NEED

    Directory of Open Access Journals (Sweden)

    Sergey Bardash

    2016-11-01

    Full Text Available Economic development of countries leads to the need improving the quality of public administration, the results of which provide economic growth, social prosperity and are facilitating to solve global problems that are facing humanity. To improve the efficiency of public administration should be effective monitoring system that can detect deviations from the planned strategic development goals, unseemly level of its operation determines the target of work, which is to establish the condition of the state financial audit in Ukraine and the definition of new uncontrollable earlier objects which are managed the state apparatus, the identification of which will improve the functionality of the system of state financial audit in Ukraine. In order to achieve the goals you need to solve the following tasks. First, should set a condition of the state economic management in Ukraine and determine the public authorities, which are subjects to implementing control functions of public administration. Second, determine the resources that have the public interest and should be controlled by the state. Third, determine the composition of objects and install a condition of government auditing system in order to improve the efficiency of these next control measures of the Accounting Chamber of Ukraine and the State Audit Service of Ukraine. The methodological basis of the study is the dialectical method, which is to implement research of financial audit in public administration, its relationship with other forms of control exercised by the state; systematic analysis of financial and economic processes, which is carrying out researching of the state financial audit in the system of relations arising between economic entities of the public and private sectors; methods of retrospective and comparative analysis of experience within the objective focus in the organization of state financial audit on the territory of Ukraine; evaluation and generalization which

  20. Modified atmospheric conditions controlling fungal growth on cheese

    DEFF Research Database (Denmark)

    Nielsen, Per Væggemose

    1997-01-01

    Effective control of fungal growth on cheese under storage conditions is of great concern for the dairy industry. Therefore we designed a research project together with the Danish dairy industry on modelling fungal growth on cheese as affected by the combined effect of storage conditions (O2 and CO......2 level, relative humidity and temperature) and the composition of the cheese. All fungal species commonly found on cheese, starter cultures as well as contaminants, were examined.The most important factors influencing fungal growth are temperature, water activity of the medium and the carbon...... a competitive advantage over other fungi in moist conditions with high carbon dioxide levels, such as inside a roquefort cheese or in gas tight grain storage. The key to success in food packaging is to recognise the food ecosystem, as it enables us to identify which micro...

  1. MODELS OF AIR TRAFFIC CONTROLLERS ERRORS PREVENTION IN TERMINAL CONTROL AREAS UNDER UNCERTAINTY CONDITIONS

    Directory of Open Access Journals (Sweden)

    Volodymyr Kharchenko

    2017-03-01

    Full Text Available Purpose: the aim of this study is to research applied models of air traffic controllers’ errors prevention in terminal control areas (TMA under uncertainty conditions. In this work the theoretical framework descripting safety events and errors of air traffic controllers connected with the operations in TMA is proposed. Methods: optimisation of terminal control area formal description based on the Threat and Error management model and the TMA network model of air traffic flows. Results: the human factors variables associated with safety events in work of air traffic controllers under uncertainty conditions were obtained. The Threat and Error management model application principles to air traffic controller operations and the TMA network model of air traffic flows were proposed. Discussion: Information processing context for preventing air traffic controller errors, examples of threats in work of air traffic controllers, which are relevant for TMA operations under uncertainty conditions.

  2. Controle Remoto: principio de funcionamento (parte 1 de 2

    Directory of Open Access Journals (Sweden)

    Marisa Almeida Cavalcante

    2013-10-01

    Full Text Available http://dx.doi.org/10.5007/2175-7941.2013v30n3p554 Este trabalho tem como principal objetivo a difusão da utilização do micro-controlador Arduino, no ensino e aprendizagem de Física Moderna. Para isso, elaboramos uma sequência didática com o objetivo de explorar o funcionamento de controles remoto. Esta sequência será apresentada em dois módulos; o primeiro deles destinado ao estudo dos fenômenos físicos envolvidos na transmissão de sinais sem fio por meio de radiação infravermelha e, que será objeto desta 1ª parte do artigo. O segundo módulo destinado à compreensão do modelo associado à lógica e interpretação dos sinais pelo receptor infravermelho. Para este último, atividades são desenvolvidas acoplando o receptor IR da serie PNA4601M ao micro-controlador Arduino, que interpreta e executa ações a partir dos códigos recebidos. Todos os experimentos propostos nestes módulos visam tornar possível a compreensão não apenas do funcionamento de um controle remoto, mas de todo o processo de comunicação envolvido e dos diferentes comandos/códigos advindos de cada tecla. Pretendemos, com isso, explorar conceitos de física a partir de instrumentos e aplicações tecnológicas presentes no dia a dia dos estudantes, tornando as aulas de Física mais dinâmicas e motivadoras.

  3. Simulation Evaluation of Controller-Managed Spacing Tools under Realistic Operational Conditions

    Science.gov (United States)

    Callantine, Todd J.; Hunt, Sarah M.; Prevot, Thomas

    2014-01-01

    Controller-Managed Spacing (CMS) tools have been developed to aid air traffic controllers in managing high volumes of arriving aircraft according to a schedule while enabling them to fly efficient descent profiles. The CMS tools are undergoing refinement in preparation for field demonstration as part of NASA's Air Traffic Management (ATM) Technology Demonstration-1 (ATD-1). System-level ATD-1 simulations have been conducted to quantify expected efficiency and capacity gains under realistic operational conditions. This paper presents simulation results with a focus on CMS-tool human factors. The results suggest experienced controllers new to the tools find them acceptable and can use them effectively in ATD-1 operations.

  4. Active Vibration Control of Plate Partly Treated with ACLD Using Hybrid Control

    Directory of Open Access Journals (Sweden)

    Dongdong Zhang

    2014-01-01

    Full Text Available A finite element model of plate partly treated with ACLD treatments is developed based on the constitutive equations of elastic, piezoelectric, viscoelastic materials and Hamilton’s principle. The Golla-Hughes-Mctavish (GHM method is employed to describe the frequency-dependent characteristics of viscoelastic material (VEM. A model reduction is completed by using iterative dynamic condensation and balance model reduction method to design an effective control system. The emphasis is concerned on hybrid (combined feedback/feedforward control system to attenuate the vibration of plates with ACLD treatments. The optimal linear quadratic Gaussian (LQG controller is considered as a feedback channel and the adaptive filtered-reference LMS (FxLMS controller is used as a feedforward channel. They can be utilized individually or in a hybrid way to suppress the vibration of plate/ACLD system. The results show that the hybrid controller which combines feedback/feedforward together can reduce the displacement amplitude of plate/ACLD system subjected to a complicated disturbance substantially without requiring more control effort. Furthermore, the hybrid controller has more rapid and stable convergence rate than the adaptive feedforward FxLMS controller. Meanwhile, perfect robustness to phase error of the cancellation path in feedforward controller and the weight matrices in feedback LQG controller is demonstrated in proposed hybrid controller. Therefore, its application in structural engineering can be highly appreciated.

  5. Instability of automotive air conditioning system with a variable displacement compressor. Part 1. Experimental investigation

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Changqing; Dou, Chunpeng; Yang, Xinjiang; Li, Xianting [Department of Building Science, School of Architecture, Tsinghua University, Beijing 100084 (People' s Republic of China)

    2005-11-01

    A test system is built first in order to investigate the instability of the automotive air conditioning (AAC) system with a variable displacement compressor (VDC), and hunting phenomena caused by the large external disturbance in the AAC system with a VDC and a thermal expansion valve, and in the AAC system with a VDC and a fixed-area throttling device are investigated experimentally in part 1 of this paper. The experimental results indicate that there also exist the hunting phenomena in the AAC system with a fixed-area throttling device. The system stability is found to be dependent on the direction of the external disturbance, and the system is apt to cause hunting when the condensing pressure decreases excessively since it may cause two-phase state at the throttling device inlet and make a large disturbance to the system. The piston stroke length will oscillate only when the oscillation amplitudes of forces acting on the wobble plate are great enough, otherwise the piston stroke length will be kept invariable, and then the system instability rule is also suitable for the AAC system with a fixed displacement compressor. From the experimental results, it is concluded that the two-phase flow at the throttling device inlet or at the evaporator outlet is the necessary condition but not sufficient condition for system hunting. Finally, a new concept, conservative stable region, is proposed based on the experimental results and theoretical analysis. (author)

  6. Gain control network conditions in early sensory coding.

    Directory of Open Access Journals (Sweden)

    Eduardo Serrano

    Full Text Available Gain control is essential for the proper function of any sensory system. However, the precise mechanisms for achieving effective gain control in the brain are unknown. Based on our understanding of the existence and strength of connections in the insect olfactory system, we analyze the conditions that lead to controlled gain in a randomly connected network of excitatory and inhibitory neurons. We consider two scenarios for the variation of input into the system. In the first case, the intensity of the sensory input controls the input currents to a fixed proportion of neurons of the excitatory and inhibitory populations. In the second case, increasing intensity of the sensory stimulus will both, recruit an increasing number of neurons that receive input and change the input current that they receive. Using a mean field approximation for the network activity we derive relationships between the parameters of the network that ensure that the overall level of activity of the excitatory population remains unchanged for increasing intensity of the external stimulation. We find that, first, the main parameters that regulate network gain are the probabilities of connections from the inhibitory population to the excitatory population and of the connections within the inhibitory population. Second, we show that strict gain control is not achievable in a random network in the second case, when the input recruits an increasing number of neurons. Finally, we confirm that the gain control conditions derived from the mean field approximation are valid in simulations of firing rate models and Hodgkin-Huxley conductance based models.

  7. Modeling validation and control analysis for controlled temperature and humidity of air conditioning system.

    Science.gov (United States)

    Lee, Jing-Nang; Lin, Tsung-Min; Chen, Chien-Chih

    2014-01-01

    This study constructs an energy based model of thermal system for controlled temperature and humidity air conditioning system, and introduces the influence of the mass flow rate, heater and humidifier for proposed control criteria to achieve the controlled temperature and humidity of air conditioning system. Then, the reliability of proposed thermal system model is established by both MATLAB dynamic simulation and the literature validation. Finally, the PID control strategy is applied for controlling the air mass flow rate, humidifying capacity, and heating, capacity. The simulation results show that the temperature and humidity are stable at 541 sec, the disturbance of temperature is only 0.14 °C, 0006 kg(w)/kg(da) in steady-state error of humidity ratio, and the error rate is only 7.5%. The results prove that the proposed system is an effective controlled temperature and humidity of an air conditioning system.

  8. Modeling Validation and Control Analysis for Controlled Temperature and Humidity of Air Conditioning System

    Directory of Open Access Journals (Sweden)

    Jing-Nang Lee

    2014-01-01

    Full Text Available This study constructs an energy based model of thermal system for controlled temperature and humidity air conditioning system, and introduces the influence of the mass flow rate, heater and humidifier for proposed control criteria to achieve the controlled temperature and humidity of air conditioning system. Then, the reliability of proposed thermal system model is established by both MATLAB dynamic simulation and the literature validation. Finally, the PID control strategy is applied for controlling the air mass flow rate, humidifying capacity, and heating, capacity. The simulation results show that the temperature and humidity are stable at 541 sec, the disturbance of temperature is only 0.14°C, 0006 kgw/kgda in steady-state error of humidity ratio, and the error rate is only 7.5%. The results prove that the proposed system is an effective controlled temperature and humidity of an air conditioning system.

  9. Petroleum residue upgrading with dispersed catalysts: Part 2. Effect of operating conditions

    Energy Technology Data Exchange (ETDEWEB)

    Panariti, N.; Del Bianco, A.; Del Piero, G. [ENITECNOLOGIE S.p.A, Via Maritano 26, 20097 San Donato Mil (Italy); Marchionna, M. [SNAMPROGETTI S.p.A, Via Maritano 26, 20097 San Donato Mil (Italy); Carniti, P. [Universita degli Studi di Milano, Dip. Chimica Fisica ed Elettrochimica, Via Celoria 20, Milan (Italy)

    2000-12-04

    The hydrotreatment of a petroleum residue in the presence of dispersed molybdenite was carried out within a wide range of operating conditions and catalyst loading. The effect of reaction severity as well as of molybdenum concentration on product distribution and quality was studied. Based on the experimental results, a simplified reaction scheme was proposed. The hydroprocessing of the residue was described in terms of the competition between two reactions: the direct conversion of the feedstock to distillate and coke, and the catalytic hydrogenation. Compared to thermal conditions, the presence of dispersed molybdenite controls very well coke formation; however, a trend of increasing formation of solids was observed at high catalyst concentrations. The overall upgrading of the feedstock requires significant amounts of molybdenum as well as relatively high hydrogen pressure.

  10. An expert system for spare parts inventory control

    International Nuclear Information System (INIS)

    Kim, K.Y.; Chen, P.Y.C.; Okrent, D.

    1987-01-01

    This paper describes an expert system which can handle spare part requirements not only in corrective maintenance (CM) or preventive maintenance (PM), but also when failure rates of components or parts are updated by new data or by predictive maintenance (PDM), and which can also decide optimum stocking level of each spare part. This expert system provides a maintenance (or inventory) manager with an improved basis for decision making in the maintenance related to spare parts. The definitions of PM and PDM from NUREG-1212 (USNRC 1986) are used herein. This expert system used Intellignece/Compiler (Intelligence Ware, 1986) as a language/tool in the IBM-PC

  11. Advanced Control Architectures for Intelligent MicroGrids, Part I

    DEFF Research Database (Denmark)

    Guerrero, Josep M.; Chandorkar, Mukul; Lee, Tzung-Lin

    2013-01-01

    This paper presents a review of advanced control techniques for microgrids. The paper covers decentralized, distributed, and hierarchical control of grid connected and islanded microgrids. At first, decentralized control techniques for microgrids are reviewed. Then, the recent developments in the...

  12. Evaluation of the performance characteristics of bilayer tablets: Part II. Impact of environmental conditions on the strength of bilayer tablets.

    Science.gov (United States)

    Kottala, Niranjan; Abebe, Admassu; Sprockel, Omar; Bergum, James; Nikfar, Faranak; Cuitiño, Alberto M

    2012-12-01

    Ambient air humidity and temperature are known to influence the mechanical strength of tablets. The objective of this work is to understand the influence of processing parameters and environmental conditions (humidity and temperature) on the strength of bilayer tablets. As part of this study, bilayer tablets were compressed with different layer ratios, dwell times, layer sequences, material properties (plastic and brittle), first and second layer forces, and lubricant concentrations. Compressed tablets were stored in stability chambers controlled at predetermined conditions (40C/45%RH, 40C/75%RH) for 1, 3, and 5 days. The axial strength of the stored tablets was measured and a statistical model was developed to determine the effects of the aforementioned factors on the strength of bilayer tablets. As part of this endeavor, a full 3 × 2(4) factorial design was executed. Responses of the experiments were analyzed using PROC GLM of SAS (SAS Institute Inc, Cary, North Carolina, USA). A model was fit using all the responses to determine the significant interactions (p < 0.05). Results of this study indicated that storage conditions and storage time have significant impact on the strength of bilayer tablets. For Avicel-lactose and lactose-Avicel tablets, tablet strength decreased with the increasing humidity and storage time. But for lactose-lactose tablets, due to the formation of solid bridges upon storage, an increase in tablet strength was observed. Significant interactions were observed between processing parameters and storage conditions on the strength of bilayer tablets.

  13. Rotor experiments in controlled conditions continued: New Mexico

    Science.gov (United States)

    Boorsma, K.; Schepers, J. G.

    2016-09-01

    To validate and reduce the large uncertainty associated with rotor aerodynamic and acoustic models, there is a need for detailed force, noise and surrounding flow velocity measurements on wind turbines under controlled conditions. However, high quality wind tunnel campaigns on horizontal axis wind turbine models are scarce due to the large wind tunnel size needed and consequently high associated costs. To serve this purpose an experiment using the Mexico turbine was set-up in the large low speed facility of the DNW wind tunnel. An overview of the experiments is given including a selection of results. A comparison of calculations to measurements for design conditions shows a satisfactory agreement. In summary, after years of preparation, ECN and partners have performed very successful aerodynamic experiments in the largest wind tunnel in Europe. The comprehensive high quality database that has been obtained will be used in the international Mexnext consortium to further develop wind energy aerodynamic and acoustic modeling.

  14. Overview of impurity control and wall conditioning in NSTX

    Energy Technology Data Exchange (ETDEWEB)

    KUGEL,H.W.; MAINGI,R.; BELL,M.; BLANCHARD,W.; GATES,D.; JOHNSON,D.; KAITA,R.; KAYE,S.; MARQUEDA,R.; MENARD,J.; MUELLER,D.; ONO,M.; PENG,Y-K.M.; RAMAN,R.; RAMSEY,A.; ROQUEMORE,A.; SKINNER,C.; SABBAGH,S.; STUTMAN,D.; WAMPLER,WILLIAM R.; WILSON,J.R.; ZWEBEN,S.

    2000-05-25

    The National Spherical Torus Experiment (NSTX) started plasma operations in February 1999, and promptly achieved high current, inner wall limited, double null, and single null plasma discharges, initial Coaxial Helicity Injection, and High Harmonic Fast Wave results. NSTX is designed to study the physics of Spherical Tori (ST) in a device that can produce non-inductively sustained high-{beta} discharges in the 1 MA regime and to explore approaches toward a small, economical high power density ST reactor core. As expected, discharge reproducibility and performance were strongly affected by wall conditions. In this paper, the authors describe the internal geometry, and initial plasma discharge, impurity control, wall conditioning, erosion, and deposition results.

  15. Numerical Simulation and Validation of a High Head Model Francis Turbine at Part Load Operating Condition

    Science.gov (United States)

    Goyal, Rahul; Trivedi, Chirag; Kumar Gandhi, Bhupendra; Cervantes, Michel J.

    2017-07-01

    Hydraulic turbines are operated over an extended operating range to meet the real time electricity demand. Turbines operated at part load have flow parameters not matching the designed ones. This results in unstable flow conditions in the runner and draft tube developing low frequency and high amplitude pressure pulsations. The unsteady pressure pulsations affect the dynamic stability of the turbine and cause additional fatigue. The work presented in this paper discusses the flow field investigation of a high head model Francis turbine at part load: 50% of the rated load. Numerical simulation of the complete turbine has been performed. Unsteady pressure pulsations in the vaneless space, runner, and draft tube are investigated and validated with available experimental data. Detailed analysis of the rotor stator interaction and draft tube flow field are performed and discussed. The analysis shows the presence of a rotating vortex rope in the draft tube at the frequency of 0.3 times of the runner rotational frequency. The frequency of the vortex rope precession, which causes severe fluctuations and vibrations in the draft tube, is predicted within 3.9% of the experimental measured value. The vortex rope results pressure pulsations propagating in the system whose frequency is also perceive in the runner and upstream the runner.

  16. Wall conditioning and particle control in Extrap T2

    Science.gov (United States)

    Bergsåker, H.; Larsson, D.; Brunsell, P.; Möller, A.; Tramontin, L.

    1997-02-01

    The Extrap T2 reversed field pinch experiment is operated with the former OHTE vacuum vessel, of dimensions R = 1.24 m and a = 0.18 m and with a complete graphite liner. It is shown that a rudimentary density control can be achieved by means of frequent helium glow discharge conditioning of the wall. The standard He-GDC is well characterized and reproducible. The trapping and release of hydrogen and impurities at the wall surfaces have been studied by mass spectrometry and surface analysis. The shot to shot particle exchange between wall and plasma can be approximately accounted for.

  17. Chemical and technological evaluation of the Phyllanthus niruri aerial parts as a function of cultivation and harvesting conditions

    Directory of Open Access Journals (Sweden)

    Angélica G. Couto

    2013-02-01

    Full Text Available Tea from Phyllanthus niruri L., Phyllanthaceae, aerial parts is commonly used by Brazilian folk medicine for its benefits on the treatment of genitourinary disorders, for what the polyphenolic compounds are mainly responsible. The yield of such compounds may be influenced by several variables related with the plant growth. The effects of planting periods and harvesting conditions are investigated in this work, including four different seasons. The cultivation was characterized by dry mass yield of aerial parts, and the effect of pruning was analyzed. Leaves, stems and their mixtures were analyzed after drying and milling. Loss on drying and water soluble extractives were used as physical parameters for quality control. Flavonoid content and gallic acid were chosen as chemical markers for this work. The spectrophotometric trial based on the aluminum chloride complexes was applied to evaluate the total flavonoids content. Gallic acid contents were measured from the water extractive solutions by high-performance liquid chromatography. The pruning caused a positive influence on the amount of leaves and stems. The highest flavonoids and gallic acid contents were found in the leaves, which were developed over the summer and the winter, respectively, both from the second harvesting (after pruning. Chomatographic profile by HPLC was characterizes by the presence of gallic acid and two other major peaks (not identified substances, which relation was peculiar to each aerial part. In conclusion, these results suggest that even under less favorable climatic conditions, in winter, the pruning seems to cause a strong influence over the P. niruri polyphenolics production. Indeed, the total flavonoids content, as well as the HPLC profile, can be used as indicative parameters of the ratio of leaves and stem in the vegetal raw material.

  18. Fuzzy logic control of air-conditioning system in residential buildings

    Directory of Open Access Journals (Sweden)

    Abdel-Hamid Attia

    2015-09-01

    Full Text Available There has been a rising concern in reducing the energy consumption in building. Heating ventilation and air condition system is the biggest consumer of energy in building. In this study, fuzzy logic control of the air conditioning system of building for efficient energy operation and comfortable environment is investigated. A theoretical model of the fan coil unit (FCU and the heat transfer between air and coolant fluid is derived. The controlled variables are the room temperature and relative humidity and control consequents are the percentage of chilled and hot water flow rates at summer and the percentage of hot water and steam injected flow rates at winter. A computer simulation has been conducted and fuzzy control results are compared with that of conventional Proportional-Integral-Derivative control. It was found that the proposed control strategy satisfies the space load and at the same time to achieve the comfort zone, as defined by the ASHRAE code. Meanwhile PID control fails to adjust the room temperature at part-load operations. It has been demonstrated that fuzzy controller operation is more efficient and consumes less energy than PID control.

  19. Parts, Materials, and Processes Control Program for Expendable Launch Vehicles

    Science.gov (United States)

    2015-05-21

    cycle cost ; and 4. Improve procurement and test of small quantities of parts and materials that meet system requirements. This document supersedes...the reliability of program PMP to reduce PMP failures at all levels of assembly and test 3. Reduce program lifecycle cost 4. Improve procurement and...part shall be procured in single lots directly from the manufacturer or its authorized franchised distributor. The contractor shall be able to

  20. Thermophysical Properties Measurement of High-Temperature Liquids Under Microgravity Conditions in Controlled Atmospheric Conditions

    Science.gov (United States)

    Watanabe, Masahito; Ozawa, Shumpei; Mizuno, Akotoshi; Hibiya, Taketoshi; Kawauchi, Hiroya; Murai, Kentaro; Takahashi, Suguru

    2012-01-01

    Microgravity conditions have advantages of measurement of surface tension and viscosity of metallic liquids by the oscillating drop method with an electromagnetic levitation (EML) device. Thus, we are preparing the experiments of thermophysical properties measurements using the Materials-Science Laboratories ElectroMagnetic-Levitator (MSL-EML) facilities in the international Space station (ISS). Recently, it has been identified that dependence of surface tension on oxygen partial pressure (Po2) must be considered for industrial application of surface tension values. Effect of Po2 on surface tension would apparently change viscosity from the damping oscillation model. Therefore, surface tension and viscosity must be measured simultaneously in the same atmospheric conditions. Moreover, effect of the electromagnetic force (EMF) on the surface oscillations must be clarified to obtain the ideal surface oscillation because the EMF works as the external force on the oscillating liquid droplets, so extensive EMF makes apparently the viscosity values large. In our group, using the parabolic flight levitation experimental facilities (PFLEX) the effect of Po2 and external EMF on surface oscillation of levitated liquid droplets was systematically investigated for the precise measurements of surface tension and viscosity of high temperature liquids for future ISS experiments. We performed the observation of surface oscillations of levitated liquid alloys using PFLEX on board flight experiments by Gulfstream II (G-II) airplane operated by DAS. These observations were performed under the controlled Po2 and also under the suitable EMF conditions. In these experiments, we obtained the density, the viscosity and the surface tension values of liquid Cu. From these results, we discuss about as same as reported data, and also obtained the difference of surface oscillations with the change of the EMF conditions.

  1. From conservative to reactive transport under diffusion-controlled conditions

    Science.gov (United States)

    Babey, Tristan; de Dreuzy, Jean-Raynald; Ginn, Timothy R.

    2016-05-01

    We assess the possibility to use conservative transport information, such as that contained in transit time distributions, breakthrough curves and tracer tests, to predict nonlinear fluid-rock interactions in fracture/matrix or mobile/immobile conditions. Reference simulated data are given by conservative and reactive transport simulations in several diffusive porosity structures differing by their topological organization. Reactions includes nonlinear kinetically controlled dissolution and desorption. Effective Multi-Rate Mass Transfer models (MRMT) are calibrated solely on conservative transport information without pore topology information and provide concentration distributions on which effective reaction rates are estimated. Reference simulated reaction rates and effective reaction rates evaluated by MRMT are compared, as well as characteristic desorption and dissolution times. Although not exactly equal, these indicators remain very close whatever the porous structure, differing at most by 0.6% and 10% for desorption and dissolution. At early times, this close agreement arises from the fine characterization of the diffusive porosity close to the mobile zone that controls fast mobile-diffusive exchanges. At intermediate to late times, concentration gradients are strongly reduced by diffusion, and reactivity can be captured by a very limited number of rates. We conclude that effective models calibrated solely on conservative transport information like MRMT can accurately estimate monocomponent kinetically controlled nonlinear fluid-rock interactions. Their relevance might extend to more advanced biogeochemical reactions because of the good characterization of conservative concentration distributions, even by parsimonious models (e.g., MRMT with 3-5 rates). We propose a methodology to estimate reactive transport from conservative transport in mobile-immobile conditions.

  2. Energy Analysis for Air Conditioning System Using Fuzzy Logic Control

    Directory of Open Access Journals (Sweden)

    Henry Nasution

    2011-04-01

    Full Text Available Reducing energy consumption and to ensure thermal comfort are two important considerations for the designing an air conditioning system. An alternative approach to reduce energy consumption proposed in this study is to use a variable speed compressor. The control strategy will be proposed using the fuzzy logic controller (FLC. FLC was developed to imitate the performance of human expert operators by encoding their knowledge in the form of linguistic rules. The system is installed on a thermal environmental room with a data acquisition system to monitor the temperature of the room, coefficient of performance (COP, energy consumption and energy saving. The measurements taken during the two hour experimental periods at 5-minutes interval times for temperature setpoints of 20oC, 22oC and 24oC with internal heat loads 0, 500, 700 and 1000 W. The experimental results indicate that the proposed technique can save energy in comparison with On/Off and proportional-integral-derivative (PID control.

  3. Fuel conditioning facility zone-to-zone transfer administrative controls

    International Nuclear Information System (INIS)

    Pope, C. L.

    2000-01-01

    The administrative controls associated with transferring containers from one criticality hazard control zone to another in the Argonne National Laboratory (ANL) Fuel Conditioning Facility (FCF) are described. FCF, located at the ANL-West site near Idaho Falls, Idaho, is used to remotely process spent sodium bonded metallic fuel for disposition. The process involves nearly forty widely varying material forms and types, over fifty specific use container types, and over thirty distinct zones where work activities occur. During 1999, over five thousand transfers from one zone to another were conducted. Limits are placed on mass, material form and type, and container types for each zone. Ml material and containers are tracked using the Mass Tracking System (MTG). The MTG uses an Oracle database and numerous applications to manage the database. The database stores information specific to the process, including material composition and mass, container identification number and mass, transfer history, and the operators involved in each transfer. The process is controlled using written procedures which specify the zone, containers, and material involved in a task. Transferring a container from one zone to another is called a zone-to-zone transfer (ZZT). ZZTs consist of four distinct phases, select, request, identify, and completion

  4. Use of statistic control of the process as part of a quality assurance plan

    International Nuclear Information System (INIS)

    Acosta, S.; Lewis, C.

    2013-01-01

    One of the technical requirements of the standard IRAM ISO 17025 for the accreditation of testing laboratories, is the assurance of the quality of the results through the control and monitoring of the factors influencing the reliability of them. The grade the factors contribute to the total measurement uncertainty, determines which of them should be considered when developing a quality assurance plan. The laboratory of environmental measurements of strontium-90 in the accreditation process, performs most of its determinations in samples with values close to the detection limit. For this reason the correct characterization of the white, is a critical parameter and is verified through a letter for statistical process control. The scope of the present work is concerned the control of whites and so it was collected a statistically significant amount of data, for a period of time that is covered of different conditions. This allowed consider significant variables in the process, such as temperature and humidity, and build a graph of white control, which forms the basis of a statistical process control. The data obtained were lower and upper limits for the preparation of the charter white control. In this way the process of characterization of white was considered to operate under statistical control and concludes that it can be used as part of a plan of insurance of the quality

  5. Monolithic Controlled Delivery Systems: Part I. Basic Characteristics and Mechanisms

    Directory of Open Access Journals (Sweden)

    Rumiana Blagoeva

    2006-04-01

    Full Text Available The article considers contemporary systems for controlled delivery of active agents, such as drugs, agricultural chemicals, pollutants and additives in the environment. A useful classification of the available controlled release systems (CRS is proposed according to the type of control (passive, active or self-preprogrammed and according to the main controlling mechanism (diffusion, swelling, dissolution or erosion. Special attention is given to some of the most used CRS - polymer monoliths. The structural and physical-chemical characteristics of CRS as well as the basic approaches to their production are examined. The basic mechanisms of controlled agent release are reviewed in detail and factors influencing the release kinetics are classified according to their importance. The present study can be helpful for understanding and applying the available mathematical models and for developing more comprehensive ones intended for design of new controlled delivery systems.

  6. A robust model predictive control strategy for improving the control performance of air-conditioning systems

    International Nuclear Information System (INIS)

    Huang Gongsheng; Wang Shengwei; Xu Xinhua

    2009-01-01

    This paper presents a robust model predictive control strategy for improving the supply air temperature control of air-handling units by dealing with the associated uncertainties and constraints directly. This strategy uses a first-order plus time-delay model with uncertain time-delay and system gain to describe air-conditioning process of an air-handling unit usually operating at various weather conditions. The uncertainties of the time-delay and system gain, which imply the nonlinearities and the variable dynamic characteristics, are formulated using an uncertainty polytope. Based on this uncertainty formulation, an offline LMI-based robust model predictive control algorithm is employed to design a robust controller for air-handling units which can guarantee a good robustness subject to uncertainties and constraints. The proposed robust strategy is evaluated in a dynamic simulation environment of a variable air volume air-conditioning system in various operation conditions by comparing with a conventional PI control strategy. The robustness analysis of both strategies under different weather conditions is also presented.

  7. Cooling water conditioning and quality control for tokamaks

    International Nuclear Information System (INIS)

    Gootgeld, A.M.

    1995-10-01

    Designers and operators of Tokamaks and all associated water cooled, peripheral equipment, are faced with the task of providing and maintaining closed-loop, low conductivity, low impurity, cooling water systems. Most of these systems must provide large volumes of high quality cooling water at reasonable cost and comply with local and state government orders and EPA mandated national pretreatment standards and regulations. This paper discusses the DIII-D water quality requirements, the means used to obtain the necessary quality and the instrumentation used for control and monitoring. Costs to mechanically and chemically condition and maintain water quality are discussed as well as the various aspects of complying with government standards and regulations

  8. Nondestructive techniques for the control of conditioned radioactive wastes

    International Nuclear Information System (INIS)

    Delprato, U.

    1987-01-01

    The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, γ-scanning, γ-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed

  9. Estimating the average treatment effect on survival based on observational data and using partly conditional modeling.

    Science.gov (United States)

    Gong, Qi; Schaubel, Douglas E

    2017-03-01

    Treatments are frequently evaluated in terms of their effect on patient survival. In settings where randomization of treatment is not feasible, observational data are employed, necessitating correction for covariate imbalances. Treatments are usually compared using a hazard ratio. Most existing methods which quantify the treatment effect through the survival function are applicable to treatments assigned at time 0. In the data structure of our interest, subjects typically begin follow-up untreated; time-until-treatment, and the pretreatment death hazard are both heavily influenced by longitudinal covariates; and subjects may experience periods of treatment ineligibility. We propose semiparametric methods for estimating the average difference in restricted mean survival time attributable to a time-dependent treatment, the average effect of treatment among the treated, under current treatment assignment patterns. The pre- and posttreatment models are partly conditional, in that they use the covariate history up to the time of treatment. The pre-treatment model is estimated through recently developed landmark analysis methods. For each treated patient, fitted pre- and posttreatment survival curves are projected out, then averaged in a manner which accounts for the censoring of treatment times. Asymptotic properties are derived and evaluated through simulation. The proposed methods are applied to liver transplant data in order to estimate the effect of liver transplantation on survival among transplant recipients under current practice patterns. © 2016, The International Biometric Society.

  10. Characterization of site conditions for selected seismic stations in eastern part of Romania

    Science.gov (United States)

    Grecu, B.; Zaharia, B.; Diaconescu, M.; Bala, A.; Nastase, E.; Constantinescu, E.; Tataru, D.

    2018-02-01

    Strong motion data are essential for seismic hazard assessment. To correctly understand and use this kind of data is necessary to have a good knowledge of local site conditions. Romania has one of the largest strong motion networks in Europe with 134 real-time stations. In this work, we aim to do a comprehensive site characterization for eight of these stations located in the eastern part of Romania. We make use of a various seismological dataset and we perform ambient noise and earthquake-based investigations to estimate the background noise level, the resonance frequencies and amplification of each site. We also derive the Vs30 parameter from the surface shear-wave velocity profiles obtained through the inversion of the Rayleigh waves recorded in active seismic measurements. Our analyses indicate similar results for seven stations: high noise levels for frequencies larger than 1 Hz, well defined fundamental resonance at low frequencies (0.15-0.29 Hz), moderate amplification levels (up to 4 units) for frequencies between 0.15 and 5-7 Hz and same soil class (type C) according to the estimated Vs30 and Eurocode 8. In contrast, the eighth station for which the soil class is evaluated of type B exhibits a very good noise level for a wide range of frequencies (0.01-20 Hz), a broader fundamental resonance at high frequencies ( 8 Hz) and a flat amplification curve between 0.1 and 3-4 Hz.

  11. Material Control and Accountability Experience at the Fuel Conditioning Facility

    International Nuclear Information System (INIS)

    Vaden, D.; Fredrickson, G.L.

    2007-01-01

    The Fuel Conditioning Facility (FCF) at the Idaho National Laboratory (INL) treats spent nuclear fuel using an electrometallurgical process that separates the uranium from the fission products, sodium thermal bond, and cladding materials. Material accountancy is necessary at FCF for two reasons: 1) it provides a mechanism for detecting a potential loss of nuclear material for safeguards and security, and 2) it provides a periodic check of inventories to ensure that processes and materials are within control limits. Material Control and Accountability is also a Department of Energy (DOE) requirement (DOE Order 474.1). The FCF employs a computer based Mass Tracking (MTG) System to collect, store, retrieve, and process data on all operations that directly affect the flow of materials through the FCF. The MTG System is important for the operations of the FCF because it supports activities such as material control and accountability, criticality safety, and process modeling. To conduct material control and accountability checks and to monitor process performance, mass balances are routinely performed around the process equipment. The equipment used in FCF for pyro-processing consists of two mechanical choppers and two electro-refiners (the Mark-IV with the accompanying element chopper and Mark-V with the accompanying blanket chopper for processing driver fuel and blanket, respectively), and a cathode processor (used for processing both driver fuel and blanket) and casting furnace (mostly used for processing driver fuel). Performing mass balances requires the measurement of the masses and compositions of several process streams and equipment inventories. The masses of process streams are obtained via in-cell balances (i.e., load cells) that weigh containers entering and leaving the process equipment. Samples taken at key locations are analyzed to determine the composition of process streams and equipment inventories. In cases where equipment or containers cannot be

  12. Spare parts inventory control under system availability constraints

    NARCIS (Netherlands)

    Houtum, van G.J.J.A.N.; Kranenburg, A.A.

    2015-01-01

    This book focuses on the tactical planning level for spare parts management. It describes a series of multi-item inventory models and presents exact and heuristic optimization methods, including greedy heuristics that work well for real, life-sized problems. The intended audience consists of

  13. Integral inventory control in spare parts networks with capacity restrictions

    NARCIS (Netherlands)

    Sleptchenko, Andrei

    2002-01-01

    Integral inventory control of repairable items in service networks can result in a significant gain compared to traditional local control mechanisms, in terms of both efficiency and customer service. Research on quantitative decision support models has yielded various useful results. However, in

  14. Analysis of Offshore Knuckle Boom Crane - Part Two: Motion Control

    Directory of Open Access Journals (Sweden)

    Morten K. Bak

    2013-10-01

    Full Text Available In this paper design of electro-hydraulic motion control systems for offshore knuckle boom cranes is discussed. The influence of the control valve bandwidth along with the ramp time for the control signal are investigated both analytically with simplified system models and numerically with an experimentally verified crane model. The results of both types of investigations are related to general design rules for selection of control valves and ramp times and the relevance of these design rules is discussed. Generally, they are useful but may be too conservative for offshore knuckle boom cranes. However, as demonstrated in the paper, the only proper way to determine this is to evaluate the motion control system design by means of simulation.

  15. Redox control of electric melters with complex feed compositions. Part I: analytical methods and models

    International Nuclear Information System (INIS)

    Bickford, D.F.; Diemer, R.B. Jr.

    1985-01-01

    The redox state of glass from electric melters with complex feed compositions is determined by balance between gases above the melt, and transition metals and organic compounds in the feed. Part I discusses experimental and computational methods of relating flowrates and other melter operating conditions to the redox state of glass, and composition of the melter offgas. Computerized thermodynamic computational methods are useful in predicting the sequence and products of redox reactions and in assessing individual process variations. Melter redox state can be predicted by combining monitoring of melter operating conditions, redox measurement of fused melter feed samples, and periodic redox measurement of product. Mossbauer spectroscopy, and other methods which measure Fe(II)/Fe(III) in glass, can be used to measure melter redox state. Part II develops preliminary operating limits for the vitrification of High-Level Radioactive Waste. Limits on reducing potential to preclude the accumulation of combustible gases, accumulation of sulfides and selenides, and degradation of melter components are the most critical. Problems associated with excessively oxidizing conditions, such as glass foaming and potential ruthenium volatility, are controlled when sufficient formic acid is added to adjust melter feed rheology

  16. The speed control of DC motor under the load condition using PI and PID controllers

    Science.gov (United States)

    Corapsiz, Muhammed Reşit; Kahveci, Hakan

    2017-04-01

    In this study, it was aimed to compare PI (Proportional-Integral) and PID (Proportional-Integral-Derivative) controllers for speed control of Permanent Magnet Direct Current (PMDC) motor under both load and without load. For this purpose, firstly, the mathematical model was obtained from the dynamic equations of the PMDC motor and the obtained mathematical model was transferred to the simulation environment and modeled using Matlab/SIMULINK. Following the modeling process, PI and PID controller structures were formed, respectively. Secondly, after these structures were formed, the PMDC motor was run without any controller. Then, the control of the PMDC motor with no load was provided by using PI and PID controllers. Finally, the PMDC motor were loaded under the constant load (TL = 3 N.m.) for each condition and selected time period (t = 3 s). The obtained result for each control operations was comparatively given by observing effects of loading process on systems. When the obtained results were evaluated for each condition, it was observed that PID controller have the best performance with respect to PI controller.

  17. A method of numerically controlled machine part programming

    Science.gov (United States)

    1970-01-01

    Computer program is designed for automatically programmed tools. Preprocessor computes desired tool path and postprocessor computes actual commands causing machine tool to follow specific path. It is used on a Cincinnati ATC-430 numerically controlled machine tool.

  18. Electronic Control Of Small Hydro-Generators Part II

    International Nuclear Information System (INIS)

    Diaz B, Pedro; Torres M, Carlos A.

    1994-01-01

    The present project arises for the Colombian population's necessity to overcome the underdevelopment, the poverty, the education and the level of life in rural areas of difficult access, for an economic rural electrification. The UIS, by means of the advisory committee of investigations of the ability of Physical-mechanical Sciences and the ability of Electricity and Electronic, it begins the process of developing in 1991 a study of economic and reliable control for the handling of small micro-centrals. Providing from electric power to the rural sector is a world problem, and have more than enough this some countries (China, Nepal, Peru, The islands of Papua, New Guinea), they have made investigations, outlining and building central micro controlled by microprocessor. The present study is developed with the objective of carrying out a load control that acts reliable and quickly. Traditionally they have been come using mechanical governors, which are those in charge of making the load control by means of valves that regulate the flow of water in the turbines, involving this way big retards characteristic of any mechanical control. In summary, the electronic governor of load presents on the mechanical governor, the advantage of acting to more speed and consequently to maintain stable the frequency of the system. To continue with the study, the objective that this project must develop, is an electronic control of load which presents to a small hydro generator, a relatively constant and independent electric load that the demanded consumption for the user varies from none to full load, given as initial parameters a constant flow in the turbine and a control in the line tension. This way it seeks to improve the energy quality given by isolated generators

  19. Dimensional control and check of field machining parts for reactor internals installation

    International Nuclear Information System (INIS)

    Zhang Caifang

    2010-01-01

    Some key issues of dimensional control for reactor internals installation are analyzed, and important technical requirements of crucial quality control elements on the measurement, machining, and checking of reactor internals filed machining parts are discussed. Moreover, provisions on quality control and risk prevention of reactor internals filed machining parts are presented in this paper. (author)

  20. Lean Production Control at a High-Variety, Low-Volume Parts Manufacturer

    NARCIS (Netherlands)

    Bokhorst, Jos A. C.; Slomp, Jannes

    2010-01-01

    Eaton Electric General Supplies, a parts manufacturing unit that supplies parts for Eaton's electrical business unit, implemented several lean control elements in its high-variety, low-volume production units. These control elements include a constant work-in-process mechanism to limit and control

  1. Synchronized mammalian cell culture: part I--a physical strategy for synchronized cultivation under physiological conditions.

    Science.gov (United States)

    Barradas, Oscar Platas; Jandt, Uwe; Becker, Max; Bahnemann, Janina; Pörtner, Ralf; Zeng, An-Ping

    2015-01-01

    Conventional analysis and optimization procedures of mammalian cell culture processes mostly treat the culture as a homogeneous population. Hence, the focus is on cell physiology and metabolism, cell line development, and process control strategy. Impact on cultivations caused by potential variations in cellular properties between different subpopulations, however, has not yet been evaluated systematically. One main cause for the formation of such subpopulations is the progress of all cells through the cell cycle. The interaction of potential cell cycle specific variations in the cell behavior with large-scale process conditions can be optimally determined by means of (partially) synchronized cultivations, with subsequent population resolved model analysis. Therefore, it is desirable to synchronize a culture with minimal perturbation, which is possible with different yield and quality using physical selection methods, but not with frequently used chemical or whole-culture methods. Conventional nonsynchronizing methods with subsequent cell-specific, for example, flow cytometric analysis, can only resolve cell-limited effects of the cell cycle. In this work, we demonstrate countercurrent-flow centrifugal elutriation as a useful physical method to enrich mammalian cell populations within different phases of a cell cycle, which can be further cultivated for synchronized growth in bioreactors under physiological conditions. The presented combined approach contrasts with other physical selection methods especially with respect to the achievable yield, which makes it suitable for bioreactor scale cultivations. As shown with two industrial cell lines (CHO-K1 and human AGE1.HN), synchronous inocula can be obtained with overall synchrony degrees of up to 82% in the G1 phase, 53% in the S phase and 60% in the G2/M phase, with enrichment factors (Ysync) of 1.71, 1.79, and 4.24 respectively. Cells are able to grow with synchrony in bioreactors over several cell cycles. This

  2. Ground-water conditions and quality in the western part of Kenai Peninsula, southcentral Alaska

    Science.gov (United States)

    Glass, R.L.

    1996-01-01

    The western part of Kenai Peninsula in southcentral Alaska is bounded by Cook Inlet and the Kenai Mountains. Ground water is the predominant source of water for commercial, industrial, and domestic uses on the peninsula. Mean daily water use in an oil, gas, and chemical processing area north of Kenai is more than 3.5 million gallons. Unconsolidated sediments of glacial and fluvial origin are the most productive aquifers. In the upper (northwestern) peninsula, almost all water used is withdrawn from unconsolidated sediments, which may be as thick as 750 feet. In the lower peninsula, unconsolidated sediments are thinner and are absent on many hills. Water supplies in the lower peninsula are obtained from unconsolidated sediments and bedrock, and a public-water supply in parts of Homer is obtained from Bridge Creek. Throughout the peninsula, ground-water flow occurs primarily as localized flow controlled by permeability of aquifer materials and surface topography. The concentration of constituents analyzed in water from 312 wells indicated that the chemical quality of ground water for human consumption varies from marginal to excellent. Even though the median concentration of dissolved solids is low (152 milligrams per liter), much of the ground water on the peninsula does not meet water-quality regulations for public drinking water established by the U.S. Environmental Protection Agency (USEPA). About 8 percent of wells sampled yielded water having concentrations of dissolved arsenic that exceeded the USEPA primary maximum contaminant level of 50 micrograms per liter. Concentrations of dissolved arsenic were as great as 94 micrograms per liter. Forty-six percent of wells sampled yielded water having concentrations of dissolved iron greater than the USEPA secondary maximum contaminant level of 300 micrograms per liter. Unconsolidated sediments generally yield water having calcium, magnesium, and bicarbonate as its predominant ions. In some areas, ground water at

  3. Dividing traffic cluster into parts by signal control

    Science.gov (United States)

    Nagatani, Takashi

    2018-02-01

    When a cluster of vehicles with various speeds moves through the series of signals, the cluster breaks down by stopping at signals and results in smaller groups of vehicles. We present the nonlinear-map model of the motion of vehicles controlled by the signals. We study the breakup of a cluster of vehicles through the series of signals. The cluster of vehicles is divided into various groups by controlling the cycle time of signals. The vehicles within each group move with the same mean velocity. The breakup of the traffic cluster depends highly on the signal control. The dependence of dividing on both cycle time and vehicular speed is clarified. Also, we investigate the effect of the irregular interval between signals on dividing.

  4. Compressor noise control begins with design--Part 1

    International Nuclear Information System (INIS)

    Frank, L.

    1993-01-01

    This paper describes the typical methods used by oil and gas pipeline companies to reduce the noise level associated with their pump and compressor stations. The common method is for the design engineer to specify an acceptable noise level at a specified distance. Unfortunately, the results by this method are rarely acceptable because vendors have not considered the effects of sound propagation outside the station, the owners have not considered the cumulative effect of various machinery, and there is little methodology available to distinguish the individual components which might be contributing the acoustically unacceptable noise levels in a multi-component system. This article stresses balanced noise control designs using noise control engineering

  5. Biomimetic propulsion under random heaving conditions, using active pitch control

    Science.gov (United States)

    Politis, Gerasimos; Politis, Konstantinos

    2014-05-01

    Marine mammals travel long distances by utilizing and transforming wave energy to thrust through proper control of their caudal fin. On the other hand, manmade ships traveling in a wavy sea store large amounts of wave energy in the form of kinetic energy for heaving, pitching, rolling and other ship motions. A natural way to extract this energy and transform it to useful propulsive thrust is by using a biomimetic wing. The aim of this paper is to show how an actively pitched biomimetic wing could achieve this goal when it performs a random heaving motion. More specifically, we consider a biomimetic wing traveling with a given translational velocity in an infinitely extended fluid and performing a random heaving motion with a given energy spectrum which corresponds to a given sea state. A formula is invented by which the instantaneous pitch angle of the wing is determined using the heaving data of the current and past time steps. Simulations are then performed for a biomimetic wing at different heave energy spectra, using an indirect Source-Doublet 3-D-BEM, together with a time stepping algorithm capable to track the random motion of the wing. A nonlinear pressure type Kutta condition is applied at the trailing edge of the wing. With a mollifier-based filtering technique, the 3-D unsteady rollup pattern created by the random motion of the wing is calculated without any simplifying assumptions regarding its geometry. Calculated unsteady forces, moments and useful power, show that the proposed active pitch control always results in thrust producing motions, with significant propulsive power production and considerable beneficial stabilizing action to ship motions. Calculation of the power required to set the pitch angle prove it to be a very small percentage of the useful power and thus making the practical application of the device very tractable.

  6. Towards the control of car underhood thermal conditions

    International Nuclear Information System (INIS)

    Khaled, Mahmoud; Harambat, Fabien; Peerhossaini, Hassan

    2011-01-01

    The present paper reports an experimental study of the aerothermal phenomena in the vehicle underhood compartment as investigated by measuring temperature, convective heat flux, and radiative heat flux. Measurements are carried out on a passenger vehicle in wind tunnel S4 of Saint-Cyr-France. The underhood space is instrumented by 120 surface and air thermocouples and 20 fluxmeters. Measurements are performed for three thermal functioning conditions while the engine is in operation and the front wheels are positioned on the test facility with power-absorption-controlled rollers. In the thermal analysis, particular attention is given to measuring absorbed convective heat fluxes at component surfaces. It is shown that, in some components, the outside air entering the engine compartment (for cooling certain components) can in fact heat other components. This problem arises from the underhood architecture, specifically the positioning of some components downstream of warmer components in the same airflow. Optimized thermal management suggests placing these components further upstream or isolating them from the hot stream by deflectors. Given style constraints, however, the use of air deflectors is more suitable than underhood architectural changes. Much of the present paper is devoted to heat flux analysis of the specific thermal behaviours in the underhood compartment (especially the absorption of convective heat fluxes) and to a description of a new control approach exploiting air deflectors to optimize underhood aerothermal management. - Research highlights: → We present a physical analysis of particular underhood aerothermal behaviors. → In this analysis, convective heat flux absorption should be noted. → A new optimization procedure based on this physical analysis is proposed. → It entails airflow redistribution in the underhood through deflectors. → The new procedures are simple and easy to implement in the car underhood.

  7. Hydrologic conditions controlling runoff generation immediately after wildfire

    Science.gov (United States)

    Ebel, Brian A.; Moody, John A.; Martin, Deborah A.

    2012-01-01

    We investigated the control of postwildfire runoff by physical and hydraulic properties of soil, hydrologic states, and an ash layer immediately following wildfire. The field site is within the area burned by the 2010 Fourmile Canyon Fire in Colorado, USA. Physical and hydraulic property characterization included ash thickness, particle size distribution, hydraulic conductivity, and soil water retention curves. Soil water content and matric potential were measured indirectly at several depths below the soil surface to document hydrologic states underneath the ash layer in the unsaturated zone, whereas precipitation and surface runoff were measured directly. Measurements of soil water content showed that almost no water infiltrated below the ash layer into the near-surface soil in the burned site at the storm time scale (i.e., minutes to hours). Runoff generation processes were controlled by and highly sensitive to ash thickness and ash hydraulic properties. The ash layer stored from 97% to 99% of rainfall, which was critical for reducing runoff amounts. The hydrologic response to two rain storms with different rainfall amounts, rainfall intensity, and durations, only ten days apart, indicated that runoff generation was predominantly by the saturation-excess mechanism perched at the ash-soil interface during the first storm and predominantly by the infiltration-excess mechanism at the ash surface during the second storm. Contributing area was not static for the two storms and was 4% (saturation excess) to 68% (infiltration excess) of the catchment area. Our results showed the importance of including hydrologic conditions and hydraulic properties of the ash layer in postwildfire runoff generation models.

  8. Control of cattle trypanosomiasis in coastal savannah of Ghana Part ...

    African Journals Online (AJOL)

    Field studies on the control of animal trypanosomiasis were undertaken in the Coastal Savanna of Ghana to det-ermine the importance of the disease in livestock production. The methodologies adopted were participatory ru-ral appraisal, geographical information systems, and entomological or parasitological evaluation.

  9. An investigation into the actual condition of radiation safety control

    International Nuclear Information System (INIS)

    Katsurayama, Kosuke

    1976-01-01

    The result of investigation on the real condition of radiation safety control is reported with some considerations. The investigation was made in April, 1975, by means of questionnaires to 418 companies, and the responses were obtained from 126 companies, i.e. 11 research laboratories, 98 manufacturing factories, and 17 inspection facilities. The average integrated dose in the inspection facilities was 0.91 rem/year, the most among three. The exposure dose in most of the research laboratories and manufacturing factories investigated was within the limit of 0.5 rem/year, and that in the inspection facilities was distributed over from the background level to 5 rem/year. The ratios of the workers engaged in radiation operation and the workers possessing the licences related to non-destructive examination to all employees were investigated, but they were not at satisfactory level. Regarding the abandonment of radioactive isotopes, 63.5% of the companies answered deliver the radioactive isotopes to be abandoned to Japan Isotope Association, and 25.7% let equipment makers to take them back. As for the education and training of operators for the safe treatment of radioactive substances and the prevention of accidents, most of the companies answered gave the education once or twice a year, and to those who just entered the companies, but more substantial education in desirable. (Nishino, S.)

  10. Radioactive contamination of Bunodosoma caissarum under controlled conditions

    International Nuclear Information System (INIS)

    Santos Gouvea, R. de C. dos; Santos, P.L. dos

    The kinetics of uptake and release of radionuclides 137 Cs, 131 I, 133 Ba, 51 Cr (III and VI), 60 Co and 65 Zn in the 'cnidaria' Bunodosoma caissarum have been studied. This is an exclusively Brazilian species and easily collected on the Rio de Janeiro coastal waters. The kinetic experiments have been made in aquariums of 1000 cm 3 , in laboratory under controlled conditions and accompanied by single channel radiometry. The velocities of concentration were evident to radionuclides 131 I and 133 Ba. The larger concentration factors were registred to 51 Cr (III), 65 Zn and 51 Cr (VI), with middle values of 20,0 , 14,5 and 8,6 respectively. The same radionuclides stood out in the loss experiments, presenting the following biological half-lives : 292,2 h ( 51 Cr-III), 784,0 h ( 51 Cr-VI) and 823,0 h ( 65 Zn). This expressive value for the 65 Zn suggests a probable biological integration of this radionuclide by the species studied. The results allow us to indicate the 'anthozoa' Bunodosoma caissarum as a bioindicator of the radioactive contamination of the marine environment. (Author) [pt

  11. Cooling water conditioning and quality control for tokamaks

    International Nuclear Information System (INIS)

    Gootgeld, A.M.

    1995-01-01

    Designers and operators of Tokamaks and all associated water cooled, peripheral equipment, are faced with the task of providing and maintaining closed-loop, low conductivity, low impurity, cooling water systems. The primary reason for supplying low conductivity water to the DIII-D vacuum vessel coils, power supplies and auxiliary heating components is to assure, along with the use of a non-conducting break in the supply piping, sufficient electrical resistance and thus an acceptable current-leakage path to ground at operating voltage potentials. As important, good quality cooling water significantly reduces the likelihood of scaling and fouling of flow passages and heat transfer surfaces. Dissolved oxygen gas removal is also required in one major DIII-D cooling water system to minimize corrosion in the ion sources of the neutral beam injectors. Currently, the combined pumping capacity of the high quality cooling water systems at DIII-D is ∼5,000 gpm. Another area that receives close attention at DIII-D is the chemical treatment of the water used in the cooling towers. This paper discusses the DIII-D water quality requirements, the means used to obtain the necessary quality and the instrumentation used for control and monitoring. Costs to mechanically and chemically condition and maintain water quality are discussed as well as the various aspects of complying with government standards and regulations

  12. Optimizing grade-control drillhole spacing with conditional simulations

    Directory of Open Access Journals (Sweden)

    Adrian Martínez-Vargas

    2017-01-01

    Full Text Available This paper summarizes a method to determine the optimum spacing of grade-control drillholes drilled with reverse-circulation. The optimum drillhole spacing was defined as that one whose cost equals the cost of misclassifying ore and waste in selection mining units (SMU. The cost of misclassification of a given drillhole spacing is equal to the cost of processing waste misclassified as ore (Type I error plus the value of the ore misclassified as waste (Type II error. Type I and Type II errors were deduced by comparing true and estimated grades at SMUs, in relation to a cuttoff grade value and assuming free ore selection. True grades at SMUs and grades at drillhole samples were generated with conditional simulations. A set of estimated grades at SMU, one per each drillhole spacing, were generated with ordinary kriging. This method was used to determine the optimum drillhole spacing in a gold deposit. The results showed that the cost of misclassification is sensitive to extreme block values and tend to be overrepresented. Capping SMU’s lost values and implementing diggability constraints was recommended to improve calculations of total misclassification costs.

  13. 76 FR 69545 - Conditions and Requirements for Relying on Component Part Testing or Certification, or Another...

    Science.gov (United States)

    2011-11-08

    ... the final rule to incorporate the concept that a finished product certifier may rely upon finished... revised, on our own initiative, the final rule to incorporate the concept that a finished product... Vol. 76 Tuesday, No. 216 November 8, 2011 Part IV Consumer Product Safety Commission 16 CFR Parts...

  14. Instrumentation and control aging management: A focus on electronic parts and boards

    International Nuclear Information System (INIS)

    Crocombette, C.; Simon, G.; Favaro, P.; Naser, J.; Guffroy, G.

    2002-01-01

    Full text: The nuclear power industry is currently facing increasing aging and obsolescence issues with original equipment installed for instrumentation, control, and safety system applications. One area that needs attention is the aging of electronic boards and components used in instrumentation and control (I and C) systems in nuclear power plants (NPPs). In this context, EPRI has launched a project dedicated to NPP electronic component and board aging management. The goals of this project are: 1) to better understand the degradation mechanisms of I and C electronic systems; 2) to develop new methods to monitor prevalent mechanisms and forecast generic aging cases; and 3) to give guidelines for the aging management of I and C electronic systems. The ultimate objectives are: 1) to reduce the likelihood of losing plant availability due to a board or component failure; and 2) to reduce the global cost of maintenance by optimizing preventive maintenance tasks and the schedule for refurbishment or renewal. Degradation mechanisms of electronic boards in NPP - Aging mechanisms of electronic parts depend on technologies, manufacturing quality, and conditions of environment and operation. Aging of electronic parts is well documented in harsh environments (e.g., aerospace, military, or automotive industries data). However, only a small amount of data on electronic part failures in NPPs is available because the conditions are benign and the failure rates are supposed to be low. It is thus difficult to identify what will predominantly cause the aging of electronic systems after 20 or 30 years of operation. Usual causes are temperature, corrosion, temperature cycles, or extrinsic aggressions (Electrical Over Stress (EOS), Electro Static Discharges (ESD)). From field data and bibliographic analyses, we found that electrolytic capacitors, relays, potentiometers, power devices (thyristors, power transistors, etc.), optocouplers, on-board connectors, printed boards, integrated

  15. Fpga As A Part Of Ms Windows Control Environment

    Directory of Open Access Journals (Sweden)

    Krzysztof Kołek

    2007-01-01

    Full Text Available The attention is focused on the Windows operating system (OS used as a control and measurementenvironment. Windows OS due to extensions becomes a real-time OS (RTOS.Benefits and drawbacks of typical software extensions are compared. As far as hardwaresolutions are concerned the field programmable gate arrays FPGA technology is proposed toensure fast time-critical operations. FPGA-based parallel execution and hardware implementationof the data processing algorithms significantly outperform the classical microprocessoroperating modes. Suitability of the RTOS for a particular application and FPGA hardwaremaintenance is studied.

  16. Pressure measurements and high speed visualizations of the cavitation phenomena at deep part load condition in a Francis turbine

    International Nuclear Information System (INIS)

    Yamamoto, K; Müller, A; Favrel, A; Landry, C; Avellan, F

    2014-01-01

    In a hydraulic power plant, it is essential to provide a reliable, sustainable and flexible energy supply. In recent years, in order to cover the variations of the renewable electricity production, hydraulic power plants are demanded to operate with more extended operating range. Under these off-design conditions, a hydraulic turbine is subject to cavitating swirl flow at the runner outlet. It is well-known that the helically/symmetrically shaped cavitation develops at the runner outlet in part load/full load condition, and it gives severe damage to the hydraulic systems under certain conditions. Although there have been many studies about partial and full load conditions, contributions reporting the deep part load condition are limited, and the cavitation behaviour at this condition is not yet understood. This study aims to unveil the cavitation phenomena at deep part load condition by high speed visualizations focusing on the draft tube cone as well as the runner blade channel, and pressure fluctuations associated with the phenomena were also investigated

  17. A Condition Based Maintenance Approach to Forecasting B-1 Aircraft Parts

    Science.gov (United States)

    2017-03-23

    Air Force Institute of Technology AFIT Scholar Theses and Dissertations 3-23-2017 A Condition Based Maintenance Approach to Forecasting B-1 Aircraft...component’s life history where reliability forecasts could be stipulated based on a component’s current condition . One of the major issues their report noted...Engine Condition Monitoring System Specification. Contract Number DOT-CG-80513-A. Grand Prairie, TX. Air Force Materiel Command. (2011) Requirements For

  18. Spring frost vulnerability of sweet cherries under controlled conditions.

    Science.gov (United States)

    Matzneller, Philipp; Götz, Klaus-P; Chmielewski, Frank-M

    2016-01-01

    Spring frost is a significant production hazard in nearly all temperate fruit-growing regions. Sweet cherries are among the first fruit varieties starting their development in spring and therefore highly susceptible to late frost. Temperatures at which injuries are likely to occur are widely published, but their origin and determination methods are not well documented. In this study, a standardized method was used to investigate critical frost temperatures for the sweet cherry cultivar 'Summit' under controlled conditions. Twigs were sampled at four development stages ("side green," "green tip," "open cluster," "full bloom") and subjected to three frost temperatures (-2.5, -5.0, -10.0 °C). The main advantage of this method, compared to other approaches, was that the exposition period and the time interval required to reach the target temperature were always constant (2 h). Furthermore, then, the twigs were placed in a climate chamber until full bloom, before the examination of the flowers and not further developed buds started. For the first two sampling stages (side green, green tip), the number of buds found in open cluster, "first white," and full bloom at the evaluation date decreased with the strength of the frost treatment. The flower organs showed different levels of cold hardiness and became more vulnerable in more advanced development stages. In this paper, we developed four empirical functions which allow calculating possible frost damages on sweet cherry buds or flowers at the investigated development stages. These equations can help farmers to estimate possible frost damages on cherry buds due to frost events. However, it is necessary to validate the critical temperatures obtained in laboratory with some field observations.

  19. Spring frost vulnerability of sweet cherries under controlled conditions

    Science.gov (United States)

    Matzneller, Philipp; Götz, Klaus-P.; Chmielewski, Frank-M.

    2016-01-01

    Spring frost is a significant production hazard in nearly all temperate fruit-growing regions. Sweet cherries are among the first fruit varieties starting their development in spring and therefore highly susceptible to late frost. Temperatures at which injuries are likely to occur are widely published, but their origin and determination methods are not well documented. In this study, a standardized method was used to investigate critical frost temperatures for the sweet cherry cultivar `Summit' under controlled conditions. Twigs were sampled at four development stages ("side green," "green tip," "open cluster," "full bloom") and subjected to three frost temperatures (-2.5, -5.0, -10.0 °C). The main advantage of this method, compared to other approaches, was that the exposition period and the time interval required to reach the target temperature were always constant (2 h). Furthermore, then, the twigs were placed in a climate chamber until full bloom, before the examination of the flowers and not further developed buds started. For the first two sampling stages (side green, green tip), the number of buds found in open cluster, "first white," and full bloom at the evaluation date decreased with the strength of the frost treatment. The flower organs showed different levels of cold hardiness and became more vulnerable in more advanced development stages. In this paper, we developed four empirical functions which allow calculating possible frost damages on sweet cherry buds or flowers at the investigated development stages. These equations can help farmers to estimate possible frost damages on cherry buds due to frost events. However, it is necessary to validate the critical temperatures obtained in laboratory with some field observations.

  20. Compressor noise control begins with design--Part 2

    International Nuclear Information System (INIS)

    Frank, L.

    1993-01-01

    Reduction of noise pollution at gas compressor stations associated with natural gas pipelines and distribution systems, has long been a complex problem. Specified noise levels of individual components tell nothing of the overall system when it is installed and placed in a site-specific setting. Further, testing for compliance performance guarantees is virtually impossible to conduct at a distant location because one cannot distinguish among various contributing noise sources. This paper develops a plan for calculating an estimate of sound generation from a compressor station and the methods for controlling and measuring sounds of individual components. It also classifies the types of noise and gives various methods of dealing with each noise type

  1. 78 FR 46295 - Special Conditions: Eclipse, EA500, Certification of Autothrottle Functions Under Part 23

    Science.gov (United States)

    2013-07-31

    ... persons (standard seating five people) and may be operated as a single or two pilot aircraft (reference...-4090. SUPPLEMENTARY INFORMATION: Comments Invited We invite interested people to take part in this...

  2. Laser Scanning Technology as Part of a Comprehensive Condition Assessment for Covered Bridges

    Science.gov (United States)

    Brian K. Brashaw; Samuel Anderson; Robert J. Ross

    2015-01-01

    New noncontact technologies have been developed and implemented for determining as-built condition and current dimensions for a wide variety of objects and buildings. In this study, a three-dimensional laser scanner was used to determine the dimensions and visual condition of a historic bridge in the Amnicon Falls State Park in northern Wisconsin. 3D scanning provides...

  3. High-definition infrared thermography of ice nucleation and propagation in wheat under natural frost conditions and controlled freezing

    Science.gov (United States)

    Infrared thermography has been used to visualize the freezing process in plants and has greatly enhanced our knowledge of ice nucleation and propagation in plants. The majority of IR analyses have been conducted under controlled rather than natural conditions and often on plant parts instead of wh...

  4. Switching robust control synthesis for teleoperation via dwell time conditions

    NARCIS (Netherlands)

    López Martínez, C.A.; van de Molengraft, M.J.G.; Steinbuch, M.; Auvray, M.; Duriez, C.

    2014-01-01

    Control design for bilateral teleoperation is still an open problem, given that it is desirable to meet a proper balance in the inherent trade-off between transparency and stability. We propose the use of switching robust control, in which smooth switching among controllers is achieved by the

  5. Working conditions of female part-time and full-time teachers in relation to health status.

    Science.gov (United States)

    Seibt, Reingard; Matz, Annerose; Hegewald, Janice; Spitzer, Silvia

    2012-08-01

    Teacher's volume of employment and health status are controversially discussed in the current literature. This study focused on female teachers with part-time versus full-time jobs in association with working conditions and health status depending on age. A sample of 263 part-time and 367 full-time female teachers (average age 46.7 ± 7.8 vs. 46.0 ± 6.3) participated in an occupational health screening. Specific work conditions, stressors (job history-questionnaire) and effort-reward-imbalance ratio (ERI-Q) were measured and their relationships to mental and physical health were analysed. Health status was quantified by complaints (BFB questionnaire), general mental health status (GHQ-12) and cardiovascular risk factors. On average, teachers in part-time positions reported 36 and in full-time positions 42 h per week. The effort-reward ratios were significantly associated with the volume of employment. Teachers in part-time jobs had only a slightly lower ERI-ratio. There were no differences between full-time and part-time teachers regarding health status. Eighteen percentage of both groups reported impaired mental health (GHQ ≥ 5), 48% of part-time teachers and 53% of full-time teachers suffered from high blood pressure. Low physical fitness was observed in 12% of part-time and 6% of full-time teachers. In this study, neither the volume of employment nor working conditions were found to be significantly correlated with health status. Part-time and full-time employment status did not appear to influence health in the teaching profession. Although there are differences in quantitative working demands, while the health status does not differ between both teacher groups.

  6. Heating, Ventilation and Air-Conditioning Systems, Part of Indoor Air Quality Design Tools for Schools

    Science.gov (United States)

    The main purposes of a Heating, Ventilation, and Air-Conditioning system are to help maintain good indoor air quality through adequate ventilation with filtration and provide thermal comfort. HVAC systems are among the largest energy consumers in schools.

  7. Muscarinic receptors in amygdala control trace fear conditioning.

    Directory of Open Access Journals (Sweden)

    Amber N Baysinger

    Full Text Available Intelligent behavior requires transient memory, which entails the ability to retain information over short time periods. A newly-emerging hypothesis posits that endogenous persistent firing (EPF is the neurophysiological foundation for aspects or types of transient memory. EPF is enabled by the activation of muscarinic acetylcholine receptors (mAChRs and is triggered by suprathreshold stimulation. EPF occurs in several brain regions, including the lateral amygdala (LA. The present study examined the role of amygdalar mAChRs in trace fear conditioning, a paradigm that requires transient memory. If mAChR-dependent EPF selectively supports transient memory, then blocking amygdalar mAChRs should impair trace conditioning, while sparing delay and context conditioning, which presumably do not rely upon transient memory. To test the EPF hypothesis, LA was bilaterally infused, prior to trace or delay conditioning, with either a mAChR antagonist (scopolamine or saline. Computerized video analysis quantified the amount of freezing elicited by the cue and by the training context. Scopolamine infusion profoundly reduced freezing in the trace conditioning group but had no significant effect on delay or context conditioning. This pattern of results was uniquely anticipated by the EPF hypothesis. The present findings are discussed in terms of a systems-level theory of how EPF in LA and several other brain regions might help support trace fear conditioning.

  8. Muscarinic receptors in amygdala control trace fear conditioning.

    Science.gov (United States)

    Baysinger, Amber N; Kent, Brianne A; Brown, Thomas H

    2012-01-01

    Intelligent behavior requires transient memory, which entails the ability to retain information over short time periods. A newly-emerging hypothesis posits that endogenous persistent firing (EPF) is the neurophysiological foundation for aspects or types of transient memory. EPF is enabled by the activation of muscarinic acetylcholine receptors (mAChRs) and is triggered by suprathreshold stimulation. EPF occurs in several brain regions, including the lateral amygdala (LA). The present study examined the role of amygdalar mAChRs in trace fear conditioning, a paradigm that requires transient memory. If mAChR-dependent EPF selectively supports transient memory, then blocking amygdalar mAChRs should impair trace conditioning, while sparing delay and context conditioning, which presumably do not rely upon transient memory. To test the EPF hypothesis, LA was bilaterally infused, prior to trace or delay conditioning, with either a mAChR antagonist (scopolamine) or saline. Computerized video analysis quantified the amount of freezing elicited by the cue and by the training context. Scopolamine infusion profoundly reduced freezing in the trace conditioning group but had no significant effect on delay or context conditioning. This pattern of results was uniquely anticipated by the EPF hypothesis. The present findings are discussed in terms of a systems-level theory of how EPF in LA and several other brain regions might help support trace fear conditioning.

  9. Control of Root Rot and Wilt Diseases of Roselle under Field Conditions

    Science.gov (United States)

    Hassan, Naglaa; Elsharkawy, Mohsen Mohamed; Shimizu, Masafumi

    2014-01-01

    Roselle (Hibiscus sabdariffa L.) is one of the most important medicinal crops in many parts of the world. In this study, the effects of microelements, antioxidants, and bioagents on Fusarium oxysporum, F. solani, and Macrophomina phaseolina, the causal pathogens of root rot and wilt diseases in roselle, were examined under field conditions. Preliminary studies were carried out in vitro in order to select the most effective members to be used in field control trials. Our results showed that microelements (copper and manganese), antioxidants (salicylic acid, ascorbic acid, and EDTA), a fungicide (Dithane M45) and biological control agents (Trichoderma harzianum and Bacillus subtilis) were significantly reduced the linear growth of the causal pathogens. Additionally, application of the previous microelements, antioxidants, a fungicide and biological control agents significantly reduced disease incidence of root rot and wilt diseases under field conditions. Copper, salicylic acid, and T. harzianum showed the best results in this respect. In conclusion, microelements, antioxidants, and biocontrol agents could be used as alternative strategies to fungicides for controlling root rot and wilt diseases in roselle. PMID:25606010

  10. Condition-based Human Reliability Assessment for digitalized control room

    International Nuclear Information System (INIS)

    Kang, H. G.; Jang, S. C.; Eom, H. S.; Ha, J. J.

    2005-04-01

    In safety-critical systems, the generation failure of an actuation signal is caused by the concurrent failures of the automated systems and an operator action. These two sources of safety signals are complicatedly correlated. The failures of sensors or automated systems will cause a lack of necessary information for a human operator and result in error-forcing contexts such as the loss of corresponding alarms and indications. In the conventional analysis, the Human Error Probabilities (HEP) are estimated based on the assumption of 'normal condition of indications and alarms'. In order to construct a more realistic signal-generation failure model, we have to consider more complicated conditions in a more realistic manner. In this study, we performed two kinds of investigation for addressing this issue. We performed the analytic calculations for estimating the effect of sensors failures on the system unavailability and plant risk. For the single-parameter safety signals, the analysis result reveals that the quantification of the HEP should be performed by focusing on the 'no alarm from the automatic system and corresponding indications unavailable' situation. This study also proposes a Condition-Based Human Reliability Assessment (CBHRA) method in order to address these complicated conditions in a practical way. We apply the CBHRA method to the manual actuation of the safety features such as a reactor trip and auxiliary feedwater actuation in Korean Standard Nuclear Power Plants. In the case of conventional single HEP method, it is very hard to consider the multiple HE conditions. The merit of CBHRA is clearly shown in the application to the AFAS generation where no dominating HE condition exits. In this case, even if the HE conditions are carefully investigated, the single HEP method cannot accommodate the multiple conditions in a fault tree. On the other hand, the application result of the reactor trip in SLOCA shows that if there is a dominating condition, the use

  11. 14 CFR 203.4 - Montreal Agreement as part of airline-passenger contract and conditions of carriage.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Montreal Agreement as part of airline-passenger contract and conditions of carriage. 203.4 Section 203.4 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS WAIVER OF WARSAW CONVENTION LIABILITY LIMITS AND DEFENSES § 203.4...

  12. Rheumatic conditions in the northern part of Central Java : an epidemiological survey

    NARCIS (Netherlands)

    J. Darmawan

    1988-01-01

    textabstractThis thesis deals with a population study on rheumatic diseases in the subdistrict Bandungan, Central Java, Indonesia. It is part of a series of epidemiological surveys executed according to the World Health Organisation - International League Against Rheumatism (WHO-ILAR) initiative

  13. 37 CFR 404.5 - Restrictions and conditions on all licenses granted under this part.

    Science.gov (United States)

    2010-07-01

    ... found by a court of competent jurisdiction to have violated the Federal antitrust laws in connection... construed to confer upon any person any immunity from or defenses under the antitrust laws or from a charge... Federal Government and the public and are not in conflict with law or this part. The following terms and...

  14. Control of uncertain systems by feedback linearization with neural networks augmentation. Part II. Controller validation by numerical simulation

    Directory of Open Access Journals (Sweden)

    Adrian TOADER

    2010-09-01

    Full Text Available The paper was conceived in two parts. Part I, previously published in this journal, highlighted the main steps of adaptive output feedback control for non-affine uncertain systems, having a known relative degree. The main paradigm of this approach was the feedback linearization (dynamic inversion with neural network augmentation. Meanwhile, based on new contributions of the authors, a new paradigm, that of robust servomechanism problem solution, has been added to the controller architecture. The current Part II of the paper presents the validation of the controller hereby obtained by using the longitudinal channel of a hovering VTOL-type aircraft as mathematical model.

  15. Air Traffic Controllers' Control Strategies in the Terminal Area Under Off-Nominal Conditions

    Science.gov (United States)

    Martin, Lynne; Mercer, Joey; Callantine, Todd; Kupfer, Michael; Cabrall, Christopher

    2012-01-01

    A human-in-the-loop simulation investigated the robustness of a schedule-based terminal-area air traffic management concept, and its supporting controller tools, to off-nominal events - events that led to situations in which runway arrival schedules required adjustments and controllers could no longer use speed control alone to impose the necessary delays. The main research question was exploratory: to assess whether controllers could safely resolve and control the traffic during off-nominal events. A focus was the role of the supervisor - how he managed the schedules, how he assisted the controllers, what strategies he used, and which combinations of tools he used. Observations and questionnaire responses revealed supervisor strategies for resolving events followed a similar pattern: a standard approach specific to each type of event often resolved to a smooth conclusion. However, due to the range of factors influencing the event (e.g., environmental conditions, aircraft density on the schedule, etc.), sometimes the plan required revision and actions had a wide-ranging effect.

  16. Direct Digital Control of HVAC (Heating, Ventilating, and Air Conditioning).

    Science.gov (United States)

    1985-01-01

    controller func- tions such as time-of-day, economizer cycles, reset, load shedding, chiller optimization , VAV fan synchronization, and optimum start/stop...control system such as that illustrated in Fig- urc 4. Data on setpoints , reset schedules, and event timing, such as that presented in Figure 6, are...program code (Figure 7). In addition to the control logic, setpoint and other data are readily available. Program logi:, setpoint and schedule data, and

  17. 42 CFR 494.30 - Condition: Infection control.

    Science.gov (United States)

    2010-10-01

    ... of potentially infectious waste; and (ii) Cleaning and disinfection of contaminated surfaces, medical... adjacent hospital or other public areas. (a) Standard: Procedures for infection control. The facility must...

  18. Current activities on improving storage conditions of the research reactor RA spent fuel - Part II

    International Nuclear Information System (INIS)

    Matausek, M.V.; Kopecni, M.; Vukadin, Z.; Plecas, I.; Pavlovic, R.; Sotic, O.; Marinkovic, N.

    1998-01-01

    To minimize further corrosion and preserve integrity of aluminum barrels and the stainless steel channel-type containers that were found to contain leaking spent fuel, actions to improve conditions in the existing spent fuel storage pool at the RA research reactor were initiated. Technology was elaborated and equipment was produced and applied for removal of sludge and other debris from the bottom of the pool, filtration of the pool water, sludge conditioning in cement matrix and disposal at the low and medium waste repository at VINCA site. More sophisticated operations are to be performed together with foreign experts. Safety measures and precautions were determined. Subcriticality was proved under normal and/or possible abnormal conditions. (author)

  19. Robust Control of an Ill-Conditioned Aircraft

    DEFF Research Database (Denmark)

    Breslin, S.G.; Tøffner-Clausen, S.; Grimble, M.J.

    1996-01-01

    A robust controller is designed for a linear model of an Advanced Short Take-Off and Vertical Landing (ASTOVL) aircraft at one operating point.......A robust controller is designed for a linear model of an Advanced Short Take-Off and Vertical Landing (ASTOVL) aircraft at one operating point....

  20. Control of DFIG-WT under unbalanced grid voltage conditions

    DEFF Research Database (Denmark)

    Luna, Alvaro; Lina, Kleber; Corcoles, Felipe

    2009-01-01

    The voltage oriented control in the synchronous reference frame (VOC-SRF) have been extensively used for controlling wind turbines based on doubly fed induction generators (DFIG-WTs) through the rotor side converter of a back to back power processor. Although its performance is fast and accurate ...

  1. Actual conditions of radiation control in radioisotope utilization field

    International Nuclear Information System (INIS)

    Kakihara, Koji

    1980-01-01

    It may be said that the actual conditions on radiation safety are being improved in utilizing radioisotopes or radiation in Japan. It depends greatly on the results of the voluntary effort of users and the regulations by the ''radiation injury prevention law'' and its relevant ordinances. However, the actual conditions of the strict observation of the law are much insufficient. According to the results of official inspection in 1978, 60% of whole enterprises concerned and 73% of educational and medical organizations were judged as incomplete. Such tendency should not be left as it is, but it should also be noticed that there are realities that critical accidents or injuries have not occurred even in such conditions as many violations mentioned above. Since the existing law has not been subjected to essential revision in the past two decades, it might be said that the law does not properly fit to the present conditions because the progress of related techniques was made during this period. Meanwhile, difficulties exist in measuring the low level concentration in the use of low energy radioisotopes or tracer experiments such as in the process analysis in factories or in the analysis of the movement of trace constituent in soil. Further, there is a problem on the necessity of securing the chief technicians handling radiation, and there is the contradiction that the chief technicians are useless in normal condition but are powerless in case of accidents. This situation should be improved as soon as possible. (Wakatsuki, Y.)

  2. Effects of environmental stress on forest crown condition in Europe. Part IV statistical analysis of relationships

    NARCIS (Netherlands)

    Klap, J.M.; Oude Voshaar, J.H.; Vries, de W.; Erisman, J.W.

    2000-01-01

    Site-specific estimates for various environmental stress factors were related with measured crown condition data at a systematic 16 x: 16 km(2) grid over Europe, according to previously stated hypotheses, using a multiple regression approach, including interactions, and lagged effects of stress

  3. Online optimal control of variable refrigerant flow and variable air volume combined air conditioning system for energy saving

    International Nuclear Information System (INIS)

    Zhu, Yonghua; Jin, Xinqiao; Du, Zhimin; Fang, Xing

    2015-01-01

    The variable refrigerant flow (VRF) and variable air volume (VAV) combined air conditioning system can solve the problem of the VRF system in outdoor air ventilation while taking advantage of its high part load energy efficiency. Energy performance of the combined air conditioning system can also be optimized by joint control of both the VRF and the VAV parts. A model-based online optimal control strategy for the combined air conditioning system is presented. Simplified adaptive models of major components of the combined air conditioning system are firstly developed for predicting system performances. And a cost function in terms of energy consumption and thermal comfort is constructed. Genetic algorithm is used to search for the optimal control sets. The optimal control strategy is tested and evaluated through two case studies based on the simulation platform. Results show that the optimal strategy can effectively reduce energy consumption of the combined air conditioning system while maintaining acceptable thermal comfort. - Highlights: • A VRF and VAV combined system is proposed. • A model-based online optimal control strategy is proposed for the combined system. • The strategy can reduce energy consumption without sacrificing thermal comfort. • Novel simplified adaptive models are firstly developed for the VRF system

  4. 32 CFR Appendix B to Part 327 - Internal Management Control Review Checklist

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 2 2010-07-01 2010-07-01 false Internal Management Control Review Checklist B... B to Part 327—Internal Management Control Review Checklist (a) Task: Personnel and/or Organization... See footnote 2 to this Appendix B. (1) I attest that the above listed internal controls provide...

  5. Distributed computation of supremal conditionally-controllable sublanguages

    Czech Academy of Sciences Publication Activity Database

    Komenda, Jan; Masopust, Tomáš

    2016-01-01

    Roč. 89, č. 2 (2016), s. 424-436 ISSN 0020-7179 R&D Projects: GA ČR GA15-02532S; GA MŠk LH13012 Institutional support: RVO:67985840 Keywords : discrete-event systems * supervisory control * coordination control Subject RIV: BA - General Mathematics Impact factor: 2.208, year: 2016 http://www.tandfonline.com/doi/full/10.1080/00207179.2015.1079736

  6. Adaptive Control of Non-Minimum Phase Modal Systems Using Residual Mode Filters2. Parts 1 and 2

    Science.gov (United States)

    Balas, Mark J.; Frost, Susan

    2011-01-01

    Many dynamic systems containing a large number of modes can benefit from adaptive control techniques, which are well suited to applications that have unknown parameters and poorly known operating conditions. In this paper, we focus on a direct adaptive control approach that has been extended to handle adaptive rejection of persistent disturbances. We extend this adaptive control theory to accommodate problematic modal subsystems of a plant that inhibit the adaptive controller by causing the open-loop plant to be non-minimum phase. We will modify the adaptive controller with a Residual Mode Filter (RMF) to compensate for problematic modal subsystems, thereby allowing the system to satisfy the requirements for the adaptive controller to have guaranteed convergence and bounded gains. This paper will be divided into two parts. Here in Part I we will review the basic adaptive control approach and introduce the primary ideas. In Part II, we will present the RMF methodology and complete the proofs of all our results. Also, we will apply the above theoretical results to a simple flexible structure example to illustrate the behavior with and without the residual mode filter.

  7. Improvement of greenhouse design and climate control in mediterranean conditions

    NARCIS (Netherlands)

    Tuzel, Yuksel; Zwart, de Feije; Sapounas, A.; Hemming, Silke; Stanghellini, Cecilia

    2017-01-01

    The Mediterranean Region is one of the most important areas of the world in terms of protected cultivation. Turkey, with its increasing greenhouse area, is one of the representative countries of the region. Thanks to the mild winter climatic conditions, cultivation of vegetables under simple

  8. Badly maintained air conditioning installations (Part 2); Schlecht gewartete Klimaanlagen (Teil 2)

    Energy Technology Data Exchange (ETDEWEB)

    Haefliger, P. E.; Thies, U.

    2002-07-01

    This article is the second of a series of four articles that discuss hygiene problems that often occur in ventilation and air-conditioning installations. They describe the problems encountered in detail, provide the reader with appropriate know-how on hygiene-related topics and present an overview of the regulations appertaining to the problems along with inspection and analysis methods. In particular, this second article examines the so-called 'Sick Building Syndrome', its technical, chemical, biological and psychosocial causes and mentions the results of studies made in this area. Typical illnesses such as allergic alveolitis and legionnaires illness are discussed. Definitions of hygiene and comfort with respect to ventilation and air-conditioning installations are presented and problem areas such as filters, ducting, humidifiers and cooling are discussed. The article is rounded off - as are all articles of this series - with a comprehensive literature list.

  9. Uranium tetrafluoride reduction closed bomb. Part I: Reduction process general conditions

    International Nuclear Information System (INIS)

    Anca Abati, R.; Lopez Rodriguez, M.

    1961-01-01

    General conditions about the metallo thermic reduction in small bombs (250 and 800 gr. of uranium) has been investigated. Factors such as kind and granulometry of the magnesium used, magnesium excess and preheating temperature, which affect yields and metal quality have been considered. magnesium excess increased yields in a 15% in the small bomb, about the preheating temperature, there is a range between which yields and metal quality does not change. All tests have been made with graphite linings. (Author) 18 refs

  10. Modeling of composite synthesis in conditions of controlled thermal explosion

    Science.gov (United States)

    Kukta, Yaroslav; Knyazeva, Anna

    2017-12-01

    The paper proposes the model for the titanium-based composite synthesis from powders of titanium and carbon of non-stoichiometric composition. The model takes into account the mixture heating from chamber walls, the dependence of liquidus and solidus temperatures on the composition of reacting mixture and the formation of possible irreversible phases. The reaction retardation by the reaction product is taken into consideration in kinetic laws. As an example, the results of temperature and conversion level calculation are presented for the system Ti-C with the summary reaction for different temperatures of chamber walls heating. It was revealed that the reaction retardation being the reaction product can be the cause of incomplete conversion in the thermal explosion conditions. Non-stoichiometric composition leads to the conditions of degenerated mode when some additional heating is necessary to complete the reaction.

  11. Transactive System: Part I: Theoretical Underpinnings of Payoff Functions, Control Decisions, Information Privacy, and Solution Concepts

    Energy Technology Data Exchange (ETDEWEB)

    Lian, Jianming [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Zhang, Wei [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sun, Y. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Marinovici, Laurentiu D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kalsi, Karanjit [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Widergren, Steven E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2018-01-17

    The increased penetration of renewable energy has significantly changed the conditions and the operational timing of the electricity grid. More flexible, faster ramping resources are needed to compensate for the uncertainty and variability introduced by renewable energy. Distributed energy resources (DERs) such as distributed generators, energy storage, and controllable loads could help manage the power grid in terms of both economic efficiency and operational reliability. In order to realize the benefits of DERs, coordination and control approaches must be designed to enable seamless integration of DERs into the power grid. Transactive coordination and control is a new approach for DER integration, where individual resources are automated and engaged through market interaction. Transactive approaches use economic signals—prices or incentives—to engage DERs. These economic signals must reflect the true value of the DER contributions, so that they seamlessly and equitably compete for the opportunities that today are only available to grid-owned assets. Value signals must be communicated to the DERs in near-real time, the assets must be imbued with new forms of distributed intelligence and control to take advantage of the opportunities presented by these signals, and they must be capable of negotiating and transacting a range of market-driven energy services. The concepts of transactive energy systems are not new, but build upon evolutionary economic changes in financial and electric power markets. These concepts also recognize the different regional structures of wholesale power markets, electricity delivery markets, retail markets, and vertically integrated service provider markets. Although transactive energy systems are not revolutionary, they will be transformational in their ability to provide flexibility and operational efficiency. A main goal of this research is to establish useful foundation for analysis of transactive energy systems and to facilitate

  12. A microcosm for the breeding of plants under controlled conditions

    International Nuclear Information System (INIS)

    D'Aquino, Luigi; Maglione, Maria Grazia; Minarini, Carla; Pandolfi Giuseppe; Lanza, Bruno; Atrigna, Mauro; De Filippo, Giovanni; Giannotta, Giovanni; Pedicini Antonio; Aprano Salvatore

    2015-01-01

    In order to enhance studies of the effects of multiple stress on plant physiology laboratory scale, in collaboration with FOS Srl and Sesmat Srl and the project application for organic PON02 0 0556 3 420580 «SMARTAGS-SMARt TAGS 'was conceived, designed and built a 'microcosm for the breeding of plants under biotic and abiotic stress conditioning '. [it

  13. Degradation of materials under conditions of thermochemical cycles for hydrogen production - part III

    International Nuclear Information System (INIS)

    Klimas, S.J.; Searle, H.; Guerout, F.

    2011-01-01

    A capsule method was employed to screen a number of materials for degradation under selected conditions of the sulphur-iodine (SI) and the copper-chlorine (Cu-Cl) thermochemical cycles. A summary of the results of an experimental investigation is given. The recommendations for the selection of the materials required for the construction of the electrolyser subsystem of the copper chlorine hybrid cycle are presented and discussed with the associated rationale. Some remaining uncertainties are illustrated on the basis of the experimental evidence gathered. (author)

  14. Characterisation of textile shape and position upstream of a wastewater pump under different part load conditions

    DEFF Research Database (Denmark)

    Jensen, Anna Lyhne; Sørensen, Henrik; Rosendahl, Lasse Aistrup

    2018-01-01

    Accumulations of sanitary textile materials often lead to clogging of pumps in the wastewater system. Simulation of clogging phenomena may help to identify means of reducing the risk of clogging. In order to provide realistic initial conditions for clogging simulations, this study characterises...... textiles in artificial wastewater in the suction pipe to a dry-installed pump at nine different operating points. The textiles are recorded approximately 3.5 pipe diameters from the pump inlet and approximately three pipe diameters from the suction pipe bend at pipe Reynolds numbers in the range 300...

  15. Studi Eksperimental Pengontrolan Air Conditioning System Dengan Fuzzy Logic Control

    Directory of Open Access Journals (Sweden)

    Sudirman -

    2012-11-01

    Full Text Available Electrical energy available in Indonesia at this time is not yet sufficient for all existing activities, this can be proved byfrequent occurrence of blackouts in several areas in Indonesia. It is necessary for a saving in electrical energy consumptionin all sectors, it is one of the refrigeration system. Research was conducted by testing AC (3 HP / 3 phase using 2 differentcontrol systems, namely conventional control and FLC. Testing is done by placing the indoor units in cold storage room.Each test performed with varying load in the test room, ie no light burden, lamp 1000 Watt, and lamp 2000 Watt. Testingusing a conventional control system set point temperature 26 ° C and 3 variations of the differential is 1 , 2 and 3 , the FLCusing the temperature setting point 26 ° C. From this research we can conclude that the application of FLC system produceselectric energy consumption of the lowest compared to conventional control in this case is the differential 1. FLC applicationof electrical energy consumption at load 1000 Watt lower 11% and the load 2000 Watt 4% lower compared withconventional control in diffrensial 1.

  16. Developed adaptive neuro-fuzzy algorithm to control air conditioning ...

    African Journals Online (AJOL)

    user

    The paper developed artificial intelligence technique adaptive neuro-fuzzy ... system is highly appreciated and essential in most of our daily life. ... It can construct an input-output mapping based on human knowledge and specific input-output data ... fuzzy controllers to produce desirable internal temperature and air quality, ...

  17. 32 CFR Appendix G to Part 505 - Management Control Evaluation Checklist

    Science.gov (United States)

    2010-07-01

    ... CIVIL AUTHORITIES AND PUBLIC RELATIONS ARMY PRIVACY ACT PROGRAM Pt. 505, App. G Appendix G to Part 505—Management Control Evaluation Checklist (a) Function. The function covered by this checklist is DA Privacy...

  18. Design of analog networks in the control theory formulation. Part 2: Numerical results

    OpenAIRE

    Zemliak, A. M.

    2005-01-01

    The paper presents numerical results of design of nonlinear electronic networks based on the problem formulation in terms of the control theory. Several examples illustrate the prospects of the approach suggested in the first part of the work.

  19. Installation of PMV Operation Program in DDC Controller and Air Conditioning Control Using PMV Directly as Set Point

    Science.gov (United States)

    Haramoto, Ken-Ichi

    In general, air conditioning control in a building is operated mainly by indoor air temperature control. Although the operators of the machine in the building accepted a claim for indoor air temperature presented by the building inhabitants, the indoor conditions have been often too cool or warm. Therefore, in an attempt to create better thermal environments, the author paid attention to the PMV that is a thermal comfort index. And then, the possibility of air conditioning control using the PMV directly as the set point was verified by employing actual equipment in an air conditioning testing room and an office building. Prior to the execution of this control, the operation program of the PMV was installed in a DDC controller for the air conditioning control. And information from indoor sensors and so on was inputted to the controller, and the computed PMV was used as the feedback variable.

  20. Existence conditions of optimal trajectories in dynamic control processes; Conditions d'existence de trajectoires optimales des processus dynamiques commandes

    Energy Technology Data Exchange (ETDEWEB)

    Bonnemay-Juricek, L [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    The existence of solutions in the optimal control problems with free endpoints is studied in this report and existence conditions are established without the usual assumption that the control region is convex. Furthermore the results, in order to be of some utility in physical applications, are expressed only by means of conditions on the parameters defining the system. (author) [French] Ce rapport etudie l'existence de solutions optimales dans les problemes de commande ou le point terminal est libre et ou la duree de l'evolution du systeme a optimiser est connue. Des conditions d'existence y sont formulees sans recourir a l'hypothese usuelle de convexite du domaine des valeurs des commandes. De plus on a cherche a rendre utilisables les resultats en ne faisant porter les conditions que sur les parametres directement accessibles du systeme. (auteur)

  1. Integrating CHWs as part of the team leading diabetes group visits: A randomized controlled feasibility study

    Science.gov (United States)

    The purpose of the study was to evaluate the feasibility of integrating Community Health Workers (CHWs) as part of the team leading diabetes group visits. This was a randomized controlled study that integrated CHWs as part of the team leading diabetes group visits for low-income Hispanic adults (n=5...

  2. Homogeneous nucleation rates of nitric acid dihydrate (NAD at simulated stratospheric conditionsPart II: Modelling

    Directory of Open Access Journals (Sweden)

    O. Möhler

    2006-01-01

    Full Text Available Activation energies ΔGact for the nucleation of nitric acid dihydrate (NAD in supercooled binary HNO3/H2O solution droplets were calculated from volume-based nucleation rate measurements using the AIDA (Aerosol, Interactions, and Dynamics in the Atmosphere aerosol chamber of Forschungszentrum Karlsruhe. The experimental conditions covered temperatures T between 192 and 197 K, NAD saturation ratios SNAD between 7 and 10, and nitric acid molar fractions of the nucleating sub-micron sized droplets between 0.26 and 0.28. Based on classical nucleation theory, a new parameterisation for ΔGact=A×(T ln SNAD−2+B is fitted to the experimental data with A=2.5×106 kcal K2 mol−1 and B=11.2−0.1(T−192 kcal mol−1. A and B were chosen to also achieve good agreement with literature data of ΔGact. The parameter A implies, for the temperature and composition range of our analysis, a mean interface tension σsl=51 cal mol−1 cm−2 between the growing NAD germ and the supercooled solution. A slight temperature dependence of the diffusion activation energy is represented by the parameter B. Investigations with a detailed microphysical process model showed that literature formulations of volume-based (Salcedo et al., 2001 and surface-based (Tabazadeh et al., 2002 nucleation rates significantly overestimate NAD formation rates when applied to the conditions of our experiments.

  3. Operational Circular No.2 (Rev. 2) - Conditions of access to the fenced parts of the CERN site

    CERN Multimedia

    2014-01-01

    Operational Circular No. 2 (Rev. 2) entitled “Conditions of access to the fenced parts of the CERN site” and its “implementation measures”, approved by the Director-General following discussion at the Standing Concertation Committee meeting on 20 May 2014 and entering into force on 1 September 2014, are available on the intranet site of the Human Resources Department (see here).   This circular is applicable to members of the personnel and other persons concerned. It cancels and replaces Operational Circular No. 2 (Rev. 1) entitled “Conditions of access to the fenced parts of the CERN site”, of April 1998. In particular, the revised circular provides for the possibility of mandating a person responsible for the proper implementation of the circular, specifies the rules relating to vehicles allowed on the site and the respective responsibilities of their owners, and relaxes certain administrative formalities in case of loss, theft or di...

  4. Operational Circular No. 2 (Rev. 3) - Conditions of access to the fenced parts of the CERN site

    CERN Multimedia

    HR Department

    2015-01-01

    Operational Circular No. 2 (Rev. 3) entitled "Conditions of access to the fenced parts of the CERN site", approved by the Director-General following discussion in the Standing Concertation Committee meeting on 24 September 2015, is now available via this link.   This revised circular cancels and replaces Operational Circular No. 2 (Rev. 2) also entitled "Conditions of access to the fenced parts of the CERN site", of September 2014. The circular was revised predominantly in order to specify that access to the CERN site is granted to CERN Pension Fund beneficiaries only provided that they are actually in receipt of payments from the Fund; and to allow the Director-General to permit special types of vehicles on site, such as trailers. It also includes a certain number of text improvements and an updated version of the implementation measures, in particular with regard to vehicle identification, road traffic and parking.  

  5. Experimental Investigation into Suitable Process Conditions for Plastic Injection Molding of Thin-Sheet Parts

    Directory of Open Access Journals (Sweden)

    Dyi-Cheng Chen

    2014-04-01

    Full Text Available This study performs an experimental investigation into the effects of the process parameters on the surface quality of injection molded thin-sheet thermoplastic components. The investigations focus specifically on the shape, number and position of the mold gates, the injection pressure and the injection rate. It can be seen that the gravity force entering point improved filling of the cavity for the same forming time and injection pressure. Moreover, it shows the same injection pressure and packing time, the taper-shape gate yields a better surface appearance than the sheet-shape gate. The experimental results provide a useful source of reference in suitable the process conditions for the injection molding of thin-sheet plastic components.

  6. Measurements of Burnout Conditions for Flow of Boiling Water in Vertical Round Ducts (Part 2)

    International Nuclear Information System (INIS)

    Becker, Kurt M.; Persson, P.; Nilsson, L.; Eriksson, O.

    1963-06-01

    The present report deals with the results of the second phase of an experimental investigation of burnout conditions for flow of boiling water in vertical round ducts. The following ranges of variables were studied and 809 burnout measurements were obtained. Pressure 5. 3 2 ; Inlet subcooling 56 sub BO 2 ; Mass velocity 100 2 s; Heated length 600 BO , were plotted against the pressure with the surface heat flux as parameter. The data have been correlated by curves, and the scatter around the curves is less than ± 5 per cent. In the ranges investigated, the observed steam quality at burnout, X BO generally decreases with increasing heat flux and mass velocity but increases with increasing pressure. The data have been compared with the empirical correlation by Tong, and excellent agreement was found for pressures higher than 10 kg/cm 2

  7. River water pollution condition in upper part of Brantas River and Bengawan Solo River

    Science.gov (United States)

    Roosmini, D.; Septiono, M. A.; Putri, N. E.; Shabrina, H. M.; Salami, I. R. S.; Ariesyady, H. D.

    2018-01-01

    Wastewater and solid waste from both domestic and industry have been known to give burden on river water quality. Most of river water quality problem in Indonesia has start in the upper part of river due to anthropogenic activities, due to inappropriate land use management including the poor wastewater infrastructure. Base on Upper Citarum River Water pollution problem, it is interesting to study the other main river in Java Island. Bengawan Solo River and Brantas River were chosen as the sample in this study. Parameters assessed in this study are as follows: TSS, TDS, pH, DO, and hexavalent chromium. The status of river water quality are assess using STORET method. Based on (five) parameters, STORET value showed that in Brantas River, Pagerluyung monitoring point had the worst quality relatively compared to other monitoring point in Brantas River with exceeding copper, lead and tin compared to the stream standard in East Java Provincial Regulation No. 2 in 2008. Brantas River was categorized as lightly polluted river based on monitoring period 2011-2015 in 5 monitoring points, namely Pendem, Sengguruh, Kademangan, Meritjan and Kertosono.

  8. Justification of evaluation criteria of the effectiveness of choice of spare parts stored in the warehouse of the transport company to maintain in good condition of its rolling stock

    Directory of Open Access Journals (Sweden)

    Antonyuk O.P.

    2016-08-01

    Full Text Available Support rolling stock of transport in good repair can be carried out using replacement parts that are stored on in the warehouses of transport enterprise and spare parts that are purchased as the need arises. For the uninterrupted transport services transport enterprise must have a certain amount of stock of spare parts at a given time. Rational organization of storage and inventory control of spare parts for motor plant affects the reducing operating costs and improving profitability of the transportation process. In the article the criteria for evaluating the effectiveness of choice of spare parts stored in the warehouse of the transport company to maintain in good condition of its rolling stock, taking into account the totality of the costs of purchase, transportation and storage of spare parts. Using these criteria allows to determine the advisability of keeping spare parts in stock of transport and procurement of necessary spare parts, provided the minimal costs of spare parts.

  9. Controlling flow conditions of test filters in iodine filters

    International Nuclear Information System (INIS)

    Holmberg, R.; Laine, J.

    1979-03-01

    Several different iodine filter and test filter designs and experience gained from their operation are presented. For the flow experiments, an iodine filter system equipped with flow regulating and measuring devices was built. In the experiments the influence of the packing method of the iodine sorption material and the influence of the flow regulating and measuring divices upon the flow conditions in the test filters was studied. On the basis of the experiments it has been shown that the flows through the test filters always can be adjusted to a correct value if there only is a high enough pressure difference available across the test filter ducting. As a result of the research, several different methods are presented with which the flows through the test filters in both operating and future iodine sorption system can easily be measured and adjusted to their correct values. (author)

  10. Hydrogen formation and control under postulated LMFBR accident conditions

    International Nuclear Information System (INIS)

    Armstrong, G.R.; Wierman, R.W.

    1976-09-01

    The objective of this study is to experimentally investigate the potential for autoignition and combustion of hydrogen-sodium mixtures which may be produced in LMFBR accidents. The purpose and ultimate usefulness of this work is to provide data that will establish the validity and acceptability of mechanisms inherent to the LMFBR that could either prevent or delay the accumulation of hydrogen gas to less than 4 percent (V) in the Reactor Containment Building (RCB) under accident conditions. The results to date indicate that sodium and sodium-hydrogen mixtures such as may be expected during LMFBR postulated accidents will ignite upon entering an air atmosphere and that the hydrogen present will be essentially all consumed until such time that the oxygen concentration is depleted

  11. Quality control of concretes for conditioning of spent radioactive sources

    International Nuclear Information System (INIS)

    Gonzalez N, M.

    2015-01-01

    The spent sealed radioactive sources are considered as a specific type of radioactive wastes and should be properly stored to ensure their integrity and prevent or limit the release of radionuclides in the geosphere. For this, these sources can be put up in concrete matrices. This research presents the evaluation and characterization of five concretes prepared with 4 brands of commercial cements: CPC Extra RS, CPC 30R Impercem of Cemex, Cruz Azul CPC 30R and CPC 30R of Apasco; three sizes of coarse aggregate (<30 mm, 29-11 mm and <10 mm) and fine aggregate (0.0797 mm) used as matrices for conditioning of spent sealed radioactive sources, in order to verify if these specific concretes accredit the standard NOM-019-Nucl-1995. After hardening for 28 days the concrete specimens were subjected to the tests: compressive strength; thermal cycles, irradiation, leaching and permeability, later to be characterized by: 1) X-ray diffraction in order to meet their crystalline phases; 2) scanning electron microscopy, to determine changes in morphology; 3) infrared spectroscopy, to determine the structural changes of concrete from its functional groups; 4) Raman spectroscopy to determine their structural changes and 5) Moessbauer spectroscopy, which determines changes in the oxidation state of iron in the concrete. According to the results and the changes presented by each concrete after applying the tests set by NOM-019-Nucl-1995, is concluded that the concrete made with cement Cemex brand (CPC 30-RS Extra), gravel of particle size 11-29 mm and sieved sand (0.0797 mm) can be used as matrices of spent sealed sources conditioning. Is remarkable a morphological and structural change of the concrete due to gamma irradiation and heat treatment. (Author)

  12. Measurements of Burnout Conditions for Flow of Boiling Water in Vertical Annuli (Part I)

    International Nuclear Information System (INIS)

    Becker, Kurt M.; Hernborg, G.

    1962-12-01

    The present report deals with measurements of burnout conditions for flow of boiling water in an annulus with an inner diameter of 9.92 mm, an outer diameter of 17 - 42 mm and a heated length of 608 mm. Data were obtained in respect of external heating only, internal heating only and dual uniform and non-uniform heating. The following ranges of variables were studied and 978 burnout measurements were obtained. Pressure 8.5 2 ; Inlet subcooling 60 sub i 2 ; Outer surface heat flux 0 o 2 ; Mass velocity 71 2 /sec; The results are presented in diagrams where the burnout steam qualities, x BO , were plotted against the pressure with the surface heat fluxes as parameters. The data have been correlated by curves. The scatter of the data around the curves is less than ± 5 per cent. In the case of equal heat fluxes on both walls of the annulus, burnout always occurred on the inner wall, and the data compared rather well with round duct data. When the annulus was heated internally only, the data showed very low burnout values in comparison with the results for dual heating and round ducts. This disagreement was explained by considering the climbing film flow model and by the fact that only a fraction of the channel perimeter was heated. For external heating the data are somewhat lower than corresponding round duct data, but rather high in comparison with internal heating. The climbing film flow model was also used to interpret this observation. For dual non-uniform heating it was found that the outer surface may be overloaded from 30 to 70 per cent compared with the inner surface without reducing the margin of safety in respect of burnout for the annulus. It was further observed that when the heat flux fox the wall on which burnout occurs is increased, the burnout steam quality for the channel decreases. If, however, the heat flux for the opposite wall is increased, the burnout steam quality also increases. It was also observed that the highest burnout values are obtained

  13. Measurements of Burnout Conditions for Flow of Boiling Water in Vertical Annuli (Part I)

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Kurt M; Hernborg, G

    1962-12-15

    The present report deals with measurements of burnout conditions for flow of boiling water in an annulus with an inner diameter of 9.92 mm, an outer diameter of 17 - 42 mm and a heated length of 608 mm. Data were obtained in respect of external heating only, internal heating only and dual uniform and non-uniform heating. The following ranges of variables were studied and 978 burnout measurements were obtained. Pressure 8.5 < 37.5 kg/cm{sup 2}; Inlet subcooling 60 < {delta}t{sub sub} < 205 deg C; Steam quality 0.1 < x < 0.91; Inner surface heat flux 0 < (q/A){sub i} < 303 W/cm{sup 2}; Outer surface heat flux 0 < (q/A){sub o} < 374 W/cm{sup 2}; Mass velocity 71 < m/F < 961 kg/m{sup 2}/sec; The results are presented in diagrams where the burnout steam qualities, x{sub BO}, were plotted against the pressure with the surface heat fluxes as parameters. The data have been correlated by curves. The scatter of the data around the curves is less than {+-} 5 per cent. In the case of equal heat fluxes on both walls of the annulus, burnout always occurred on the inner wall, and the data compared rather well with round duct data. When the annulus was heated internally only, the data showed very low burnout values in comparison with the results for dual heating and round ducts. This disagreement was explained by considering the climbing film flow model and by the fact that only a fraction of the channel perimeter was heated. For external heating the data are somewhat lower than corresponding round duct data, but rather high in comparison with internal heating. The climbing film flow model was also used to interpret this observation. For dual non-uniform heating it was found that the outer surface may be overloaded from 30 to 70 per cent compared with the inner surface without reducing the margin of safety in respect of burnout for the annulus. It was further observed that when the heat flux fox the wall on which burnout occurs is increased, the burnout steam quality for the

  14. Study on the optium operation of the solar assisted air-source heat pump system. Part 5. ; Fundamental performance of a SOL-AIR PANEL effected by environmental condition that can be controlled artifically. SOL-AIR heat pump system no saiteki untenho ni kansuru kenkyu. 5. ; Jinko kankyo joken hendo ni uoru shuhonetsu panel no kiso tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Y; Ohashi, K; Kasuya, A [Kogauin Univ., Tokyo (Japan); Shiraishi, K; Hino, T [Kajima Institute of Construction Technology, Tokyo (Japan)

    1990-12-06

    This paper follows the privious paper which reports about the experimental system of the solar air panel and the experimental conditions in the artificial environmental room. In this paper the basic performance of heat exchange of a solar panel related to the difference of the artificial enviromental conditions such as the wind speed, the wind direction, the radiation, and the dry or wet surface of the solar air panel, and the results of its analysis are presented. As a result of the experiment, the following were determined: wind direction affects the heat exchange characteristics of the solar air panel; the slits lead to improved heat conduction on both sides of the panel; and when the flat surface of the panel is wet the amount of all the heat exchange increases, due to increased air circulation and evaporation. It is possible to estimate the total quantity of heat exchange, and to determine the fundamental performance of a solar air panel. 7 refs., 10 figs.

  15. Hydro-climatic conditions and thermoelectric electricity generation – Part I: Development of models

    International Nuclear Information System (INIS)

    Koch, Hagen; Vögele, Stefan

    2013-01-01

    In recent years there have been several heat waves affecting the use of thermoelectric power plants, e.g. in Europe and the U.S. In this paper the linkage between hydro-climatic conditions and possible electricity generation restrictions is described. The coupling of hydrological models and a power plant model is presented. In this approach each power plant is considered separately with its technical specifications. Also environmental regulations, e.g. permissible rise in the cooling water temperature, are considered for the respective power plant. The hydrological models developed to simulate river runoff and water temperature are also site specific. The approach presented is applied to Krümmel nuclear power plant in Germany. Analysed are the uncertainties with regard to electricity generation restrictions on account of climatic developments and corresponding higher water temperatures and low flows. Overall, increased water temperatures and declining river runoff lead to more frequent and more severe generation restrictions. It is concluded that the site-specific approach is necessary to reliably simulate power plants water demand, river runoff and water temperature. Using a simulation time step of one day, electricity generation restrictions are significantly higher than for simulations at monthly time step. - Highlights: • An approach to assess climate effects on electricity generation is presented. • Site specific models for power plants, water temperature and discharge are used. • Monthly and daily simulation time-steps give different results. • Climate change effects on generation depend on cooling system and climate scenario

  16. Imaging the cranial nerves: part II: primary and secondary neoplastic conditions and neurovascular conflicts

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Alexandra [Instituto Portugues de Oncologia Francisco Gentil- Centro de Lisboa, Radiology Department, Lisboa Codex (Portugal); Casselman, Jan [A. Z. St Jan Brugge and A. Z. St Augustinus Antwerpen Hospitals, Department of Radiology, Antwerp (Belgium)

    2007-09-15

    There have been unprecedented improvements in cross-sectional imaging in the last decades. The emergence of volumetric CT, higher field MR scanners and higher resolution MR sequences is largely responsible for the increasing diagnostic yield of imaging in patients presenting with cranial nerve deficits. The introduction of parallel MR imaging in combination with small surface coils allows the depiction of submillimetric nerves and nerve branches, and volumetric CT and MR imaging is able to provide high quality multiplanar and curved reconstructions that can follow the often complex course of cranial nerves. Seeking the cause of a cranial nerve deficit is a common indication for imaging, and it is not uncommon that radiologists are the first specialists to see a patient with a cranial neuropathy. To increase the diagnostic yield of imaging, high-resolution studies with smaller fields of view are required. To keep imaging studies within a reasonable time frame, it is mandatory to tailor the study according to neuro-topographic testing. This review article focuses on the contribution of current imaging techniques in the depiction of primary and secondary neoplastic conditions affecting the cranial nerves as well as on neurovascular conflicts, an increasingly recognized cause of cranial neuralgias. (orig.)

  17. Imaging the cranial nerves: part II: primary and secondary neoplastic conditions and neurovascular conflicts

    International Nuclear Information System (INIS)

    Borges, Alexandra; Casselman, Jan

    2007-01-01

    There have been unprecedented improvements in cross-sectional imaging in the last decades. The emergence of volumetric CT, higher field MR scanners and higher resolution MR sequences is largely responsible for the increasing diagnostic yield of imaging in patients presenting with cranial nerve deficits. The introduction of parallel MR imaging in combination with small surface coils allows the depiction of submillimetric nerves and nerve branches, and volumetric CT and MR imaging is able to provide high quality multiplanar and curved reconstructions that can follow the often complex course of cranial nerves. Seeking the cause of a cranial nerve deficit is a common indication for imaging, and it is not uncommon that radiologists are the first specialists to see a patient with a cranial neuropathy. To increase the diagnostic yield of imaging, high-resolution studies with smaller fields of view are required. To keep imaging studies within a reasonable time frame, it is mandatory to tailor the study according to neuro-topographic testing. This review article focuses on the contribution of current imaging techniques in the depiction of primary and secondary neoplastic conditions affecting the cranial nerves as well as on neurovascular conflicts, an increasingly recognized cause of cranial neuralgias. (orig.)

  18. Measurements of Burnout Conditions for Flow of Boiling Water in Vertical Round Ducts (Part 2)

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Kurt M; Persson, P; Nilsson, L; Eriksson, O

    1963-06-15

    The present report deals with the results of the second phase of an experimental investigation of burnout conditions for flow of boiling water in vertical round ducts. The following ranges of variables were studied and 809 burnout measurements were obtained. Pressure 5. 3 < p < 37. 3 kg/cm{sup 2}; Inlet subcooling 56 < {delta}t{sub sub} < 212 deg C; Steam quality 0. 20 < x{sub BO} < 0.95; Heat Flux 50 < q/A < 515 W/cm{sup 2}; Mass velocity 100 < m'/F < 1890 kg/m{sup 2}s; Heated length 600 < L < 2500 mm; Duct diameter d = 10 mm. The results are presented in diagrams, where for a certain geometry, the burnout steam qualities, x{sub BO} , were plotted against the pressure with the surface heat flux as parameter. The data have been correlated by curves, and the scatter around the curves is less than {+-} 5 per cent. In the ranges investigated, the observed steam quality at burnout, X{sub BO} generally decreases with increasing heat flux and mass velocity but increases with increasing pressure. The data have been compared with the empirical correlation by Tong, and excellent agreement was found for pressures higher than 10 kg/cm{sup 2}.

  19. Constitutive correlations for wire-wrapped subchannel analysis under forced and mixed convection conditions. Part 1

    International Nuclear Information System (INIS)

    Cheng, S.K.; Todreas, N.E.

    1984-08-01

    A simple subchannel analysis method based on the ENERGY series of codes, ENERGY-IV, has been established for predicting the temperature field in a single isolated wire-wrapped Liquid Metal Fast Breeder Reactor (LMFBR) subassembly under steady state forced and mixed convection conditions. The ENERGY-IV is a totally empirical code employed for fast running purposes and requires well calibrated lead length averaged input parameters to achieve satisfactory predictions. These input parameters were identified to be the inlet flow split parameters, the subchannel friction factors, the interchannel mixing parameters, the conduction shape factor, and the transverse velocity at the edge gap. Experiments were performed in a 37-pin wire-wrapped rod bundle with a geometry between that of a typical LMFBR fuel subassembly and blanket subassembly for filling the gap in the available data base for the input parameters. The isokinetic extraction method for measuring subchannel velocity, the pitot-static probe for measuring pressure drop, and the salt tracer injection method for estimating the interchannel mixing, were used in these experiments

  20. An illustration of new methods in machine condition monitoring, Part I: stochastic resonance

    International Nuclear Information System (INIS)

    Worden, K.; Antoniadou, I.; Marchesiello, S.; Mba, C.; Garibaldi, L.

    2017-01-01

    There have been many recent developments in the application of data-based methods to machine condition monitoring. A powerful methodology based on machine learning has emerged, where diagnostics are based on a two-step procedure: extraction of damage-sensitive features, followed by unsupervised learning (novelty detection) or supervised learning (classification). The objective of the current pair of papers is simply to illustrate one state-of-the-art procedure for each step, using synthetic data representative of reality in terms of size and complexity. The first paper in the pair will deal with feature extraction. Although some papers have appeared in the recent past considering stochastic resonance as a means of amplifying damage information in signals, they have largely relied on ad hoc specifications of the resonator used. In contrast, the current paper will adopt a principled optimisation-based approach to the resonator design. The paper will also show that a discrete dynamical system can provide all the benefits of a continuous system, but also provide a considerable speed-up in terms of simulation time in order to facilitate the optimisation approach. (paper)

  1. Measurements of Burnout Conditions for Flow of Boiling Water in Vertical Round Ducts (Part 2)

    Energy Technology Data Exchange (ETDEWEB)

    Becker, Kurt M; Mathisen, R P; Eklind, O; Norman, B

    1964-01-15

    The hydrodynamic stability and the burnout conditions for flow of boiling water have been studied in a natural circulation loop in the pressure range from 10 to 70 atg. The test section was a round, duct of 20 mm inner diameter and 4890 mm heated length. The experimental results showed that within the ranges tested the stability of the flow increases with increasing pressure, increasing throttling before the test section, but decreases with increasing inlet sub-cooling and increasing throttling after the test section. The measured thresholds of instability compared well with the analytical results by Jahnberg. For an inlet sub-cooling temperature of about 2 deg C the measured burnout steam qualities were low by a factor of about 1.3 compared to forced circulation data obtained with the same test section. At higher sub-cooling temperatures the discrepancy between forced and natural circulation data increased, so that at {delta}t{sub sub} = 16 deg C, the natural circulation data were low by a factor of about 2.5. However, by applying inlet throttling of the flow the burnout values approached and finally coincided with the forced circulation data.

  2. Factors influencing adult physical health after controlling for current health conditions: evidence from a british cohort.

    Directory of Open Access Journals (Sweden)

    Helen Cheng

    Full Text Available This study explored a longitudinal data set of 6875 British adults examining the effects of parental social status (measured at birth, cognitive ability (at age 11 yrs, personality traits, education and occupational attainment on physical health and functioning (all measured at age 50 yrs, after taking account of current health conditions (number of illness. Correlation analysis showed that parental social class, childhood cognitive ability, education and occupation, and two personality traits (Emotional Stability/Neuroticism, and Conscientiousness were all significantly associated with adult physical health variables. Structural equation modelling showed that health conditions and personality traits were significantly, and inversely, associated with physical health (indicated by good daily physical functioning, relative absence of pain, perceived health, and low level of limitations at work due to physical health. Parental social status, childhood intelligence, educational and occupational attainment were all modestly, but significantly and directly, associated with adult physical health. The effect of childhood intelligence on adult physical health was, in part, mediated through Emotional Stability and Conscientiousness. After controlling for health conditions Emotional Stability was the strongest predictor of physical health. Implications and limitations are discussed.

  3. Monitoring parameters of technical condition and safety of aircraft using control charts

    Directory of Open Access Journals (Sweden)

    В.І. Чепіженко

    2007-03-01

    Full Text Available  The opportunity of control cards use for monitoring of a technical condition parameters and reliability of aviation techniques is considered at its operation on a technical condition.

  4. Proceedings of the 2004 NASA/ONR Circulation Control Workshop, Part 2

    Science.gov (United States)

    Jones, Gregory S. (Editor); Joslin, Ronald D. (Editor)

    2005-01-01

    This conference proceeding is comprised of papers that were presented at the NASA/ONR Circulation Control Workshop held 16-17 March 2004 at the Radisson-Hampton in Hampton, VA. Over two full days, 30 papers and 4 posters were presented with 110 scientists and engineers in attendance, representing 3 countries. As technological advances influence the efficiency and effectiveness of aerodynamic and hydrodynamic applications, designs, and operations, this workshop was intended to address the technologies, systems, challenges and successes specific to Coanda driven circulation control in aerodynamics and hydrodynamics. A major goal of this workshop was to determine the state-of-the-art in circulation control and to assess the future directions and applications for circulation control. The 2004 workshop addressed applications, experiments, computations, and theories related to circulation control, emphasizing fundamental physics, systems analysis, and applied research. The workshop consisted of single session oral presentations, posters, and written papers that are documented in this unclassified conference proceeding. The format of this written proceeding follows the agenda of the workshop. Each paper is followed with the presentation given at the workshop. the editors compiled brief summaries for each effort that is at the end of this proceeding. These summaries include the paper, oral presentation, and questions or comments that occurred during the workshop. The 2004 Circulation Control Workshop focused on applications including Naval vehicles (Surface and Underwater vehicles), Fixed Wing Aviation (general aviation, commercial, cargo, and business aircraft); V/STOL platforms (helicopters, military aircraft, tilt rotors); propulsion systems (propellers, jet engines, gas turbines), and ground vehicles (automotive, trucks, and other); wind turbines, and other nontraditional applications (e.g., vacuum cleaner, ceiling fan). As part of the CFD focus area of the 2004 CC

  5. Analysis and Optimal Condition of the Rear-Sound-Aided Control Source in Active Noise Control

    Directory of Open Access Journals (Sweden)

    Karel Kreuter

    2011-01-01

    Full Text Available An active noise control scenario of simple ducts is considered. The previously suggested technique of using an single loudspeaker and its rear sound to cancel the upstream sound is further examined and compared to the bidirectional solution in order to give theoretical proof of its advantage. Firstly, a model with a new approach for taking damping effects into account is derived based on the electrical transmission line theory. By comparison with the old model, the new approach is validated, and occurring differences are discussed. Moreover, a numerical application with the consideration of damping is implemented for confirmation. The influence of the rear sound strength on the feedback-path system is investigated, and the optimal condition is determined. Finally, it is proven that the proposed source has an advantage of an extended phase lag and a time delay in the feedback-path system by both frequency-response analysis and numerical calculation of the time response.

  6. Intelligent Approach to Inventory Control in Logistics under Uncertainty Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Więcek, P.

    2016-07-01

    The article presents a proposal for a combined application of fuzzy logic and genetic algorithms to control the procurement process in the enterprise. The approach presented in this paper draws particular attention to the impact of external random factors in the form of demand and lead time uncertainty. The model uses time-variable membership function parameters in a dynamic fashion to describe the modelled output fuzzy (sets) values. An additional element is the use of genetic algorithms for optimisation of fuzzy rule base in the proposed method. The approach presented in this paper was veryfied according to four criteria based on a computer simulation performed on the basis of the actual data from an enterprise. (Author)

  7. A novel capacity controller for a three-evaporator air conditioning (TEAC) system for improved indoor humidity control

    International Nuclear Information System (INIS)

    Yan, Huaxia; Deng, Shiming; Chan, Ming-yin

    2016-01-01

    Highlights: • A novel capacity controller for TEAC systems for improved indoor humidity control is developed. • The novel controller was developed by integrating two previous control algorithms. • Experimental controllability tests were carried out. • Improved control over indoor humidity levels and higher energy efficiency can be achieved. - Abstract: Using a multi-evaporator air conditioning (MEAC) system to correctly control indoor air temperatures only in a multi-room application is already a challenging and difficult task, let alone the control of both indoor air temperature and humidity. This is because in an MEAC system, a number of indoor units are connected to a common condensing unit. Hence, the interferences among operation parameters of different indoor units would make the desired control of an MEAC system hard to realize. Limited capacity control algorithms for MEAC systems have been developed, with most of them focusing only on the control of indoor air temperature, and no previous studies involving control of indoor air humidity using MEAC systems can be identified. In this paper, the development of a novel capacity controller for a three-evaporator air conditioning (TEAC) system for improved indoor air humidity control is reported. The novel controller was developed by integrating two previous control algorithms for a dual-evaporator air conditioning system for temperature control and for a single-evaporator air conditioning system for improved indoor humidity control. Experimental controllability tests were carried out and the controllability test results showed that, with the novel controller, improved control over indoor humidity levels and better energy efficiency for a TEAC system could be obtained as compared to the traditional On–Off controllers extensively used by MEAC systems.

  8. Plant neighbour identity matters to belowground interactions under controlled conditions.

    Science.gov (United States)

    Armas, Cristina; Pugnaire, Francisco Ignacio

    2011-01-01

    Root competition is an almost ubiquitous feature of plant communities with profound effects on their structure and composition. Far beyond the traditional view that plants interact mainly through resource depletion (exploitation competition), roots are known to be able to interact with their environment using a large variety of mechanisms that may inhibit or enhance access of other roots to the resource or affect plant growth (contest interactions). However, an extensive analysis on how these contest root interactions may affect species interaction abilities is almost lacking. In a common garden experiment with ten perennial plant species we forced pairs of plants of the same or different species to overlap their roots and analyzed how belowground contest interactions affected plant performance, biomass allocation patterns, and competitive abilities under abundant resource supply. Our results showed that net interaction outcome ranged from negative to positive, affecting total plant mass and allocation patterns. A species could be a strong competitor against one species, weaker against another one, and even facilitator to a third species. This leads to sets of species where competitive hierarchies may be clear but also to groups where such rankings are not, suggesting that intransitive root interactions may be crucial for species coexistence. The outcome of belowground contest interactions is strongly dependent on neighbours' identity. In natural plant communities this conditional outcome may hypothetically help species to interact in non-hierarchical and intransitive networks, which in turn might promote coexistence.

  9. Numerical simulation of controlled directional solidification under microgravity conditions

    Science.gov (United States)

    Holl, S.; Roos, D.; Wein, J.

    The computer-assisted simulation of solidification processes influenced by gravity has gained increased importance during the previous years regarding ground-based as well as microgravity research. Depending on the specific needs of the investigator, the simulation model ideally covers a broad spectrum of applications. These primarily include the optimization of furnace design in interaction with selected process parameters to meet the desired crystallization conditions. Different approaches concerning the complexity of the simulation models as well as their dedicated applications will be discussed in this paper. Special emphasis will be put on the potential of software tools to increase the scientific quality and cost-efficiency of microgravity experimentation. The results gained so far in the context of TEXUS, FSLP, D-1 and D-2 (preparatory program) experiments, highlighting their simulation-supported preparation and evaluation will be discussed. An outlook will then be given on the possibilities to enhance the efficiency of pre-industrial research in the Columbus era through the incorporation of suitable simulation methods and tools.

  10. 14 CFR Appendix I to Part 25 - Installation of an Automatic Takeoff Thrust Control System (ATTCS)

    Science.gov (United States)

    2010-01-01

    ... Appendix I to Part 25—Installation of an Automatic Takeoff Thrust Control System (ATTCS) I25.1General. (a... crew to increase thrust or power. I25.2Definitions. (a) Automatic Takeoff Thrust Control System (ATTCS... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Installation of an Automatic Takeoff Thrust...

  11. 41 CFR 61-250.99 - What is the OMB control number for this part?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true What is the OMB control... TRAINING SERVICE, DEPARTMENT OF LABOR 250-ANNUAL REPORT FROM FEDERAL CONTRACTORS § 61-250.99 What is the OMB control number for this part? Pursuant to the Paperwork Reduction Act, 44 U.S.C. 3501 et seq., and...

  12. 41 CFR 61-300.99 - What is the OMB control number for this part?

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true What is the OMB control... TRAINING SERVICE, DEPARTMENT OF LABOR 300-ANNUAL REPORT FROM FEDERAL CONTRACTORS § 61-300.99 What is the OMB control number for this part? Pursuant to the Paperwork Reduction Act, 44 U.S.C. 3501 et seq., and...

  13. Improving the Quality of Hot Stamping Parts with Innovative Press Technology and Inline Process Control

    Science.gov (United States)

    Vollmer, R.; Palm, C.

    2017-09-01

    The increasing number of hot stamped parts in the automotive industry is challenging different process areas. This paper presents a method how to improve the production rates over the whole life cycle of a hot forming part. In the core element of a hot forming line, the hydraulic press, mainly two processing steps are performed. Forming and quenching of the sheet metal part. In addition to the forming operation, it is inevitable to optimize the quenching condition in the bottom dead centre in order to reach a fully martensitic structure and tight geometrical tolerances of the part. Deviations in the blank thickness, tool wear, polishing of classical tools impair the quenching condition and therefore the part quality over the time. A new press and tool design has been developed to counter this effect by providing homogenous contact pressure over the whole die. Especially with a multi cavity tool, the new method is advantageous. Test series have shown that the new tool and press concept can produce parts with a blank thickness of 1.0 mm within 8.0 s cycle time. The so called PCH flex principle makes it possible to produce such high output rates under reliable conditions.

  14. Controlled Nonlinear Stochastic Delay Equations: Part II: Approximations and Pipe-Flow Representations

    International Nuclear Information System (INIS)

    Kushner, Harold J.

    2012-01-01

    This is the second part of a work dealing with key issues that have not been addressed in the modeling and numerical optimization of nonlinear stochastic delay systems. We consider new classes of models, such as those with nonlinear functions of several controls (such as products), each with is own delay, controlled random Poisson measure driving terms, admissions control with delayed retrials, and others. Part I was concerned with issues concerning the class of admissible controls and their approximations, since the classical definitions are inadequate for our models. This part is concerned with transportation equation representations and their approximations. Such representations of nonlinear stochastic delay models have been crucial in the development of numerical algorithms with much reduced memory and computational requirements. The representations for the new models are not obvious and are developed. They also provide a template for the adaptation of the Markov chain approximation numerical methods.

  15. Distributed adaptive asymptotically consensus tracking control of uncertain Euler-Lagrange systems under directed graph condition.

    Science.gov (United States)

    Wang, Wei; Wen, Changyun; Huang, Jiangshuai; Fan, Huijin

    2017-11-01

    In this paper, a backstepping based distributed adaptive control scheme is proposed for multiple uncertain Euler-Lagrange systems under directed graph condition. The common desired trajectory is allowed totally unknown by part of the subsystems and the linearly parameterized trajectory model assumed in currently available results is no longer needed. To compensate the effects due to unknown trajectory information, a smooth function of consensus errors and certain positive integrable functions are introduced in designing virtual control inputs. Besides, to overcome the difficulty of completely counteracting the coupling terms of distributed consensus errors and parameter estimation errors in the presence of asymmetric Laplacian matrix, extra information transmission of local parameter estimates are introduced among linked subsystem and adaptive gain technique is adopted to generate distributed torque inputs. It is shown that with the proposed distributed adaptive control scheme, global uniform boundedness of all the closed-loop signals and asymptotically output consensus tracking can be achieved. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Controlling the quality of replacement parts in nuclear station, class 1E equipment

    International Nuclear Information System (INIS)

    Pierson, R.K.; Clemons, R.W.

    1984-01-01

    Nuclear station owners have traditionally purchased replacement parts for Class 1E equipment from the original supplier of the equipment. By this method, part and equipment quality could be maintained. In recent years, however, this traditional source of parts has continuously declined as an increasing number of original equipment suppliers stop producing Class 1E equipment or no longer stock parts for older equipment. When replacement parts for Class 1E equipment are not obtainable from the original suppliers, equipment owners have created a variety of methods for assuring the quality of parts obtained from other sources. A standard that provides direction and guidance for maintaining the quality of Class 1E equipment when repaired with parts from alternate sources is, therefore, needed to assure the methods in use are satisfactory and to alert the equipment owners to additional acceptable methods. The standard has now been proposed. IEEE Standard P934 (June, 1983 Draft): ''Requirements for Replacement Parts for Class 1E Equipment in Nuclear Power Generating Stations'' (Ref-3) consist of an introductory section followed by sections on part selection, procurement, replacement (including inspections and tests), non-conforming conditions and records. The proposed standard also includes a non-mandatory appendix on acceptable procurement methods and a summary intended to assist the user in selecting a proper procurement method

  17. Towards energy efficient operation of Heating, Ventilation and Air Conditioning systems via advanced supervisory control design

    Science.gov (United States)

    Oswiecinska, A.; Hibbs, J.; Zajic, I.; Burnham, K. J.

    2015-11-01

    This paper presents conceptual control solution for reliable and energy efficient operation of heating, ventilation and air conditioning (HVAC) systems used in large volume building applications, e.g. warehouse facilities or exhibition centres. Advanced two-level scalable control solution, designed to extend capabilities of the existing low-level control strategies via remote internet connection, is presented. The high-level, supervisory controller is based on Model Predictive Control (MPC) architecture, which is the state-of-the-art for indoor climate control systems. The innovative approach benefits from using passive heating and cooling control strategies for reducing the HVAC system operational costs, while ensuring that required environmental conditions are met.

  18. Experimental analysis of fuzzy controlled energy efficient demand controlled ventilation economizer cycle variable air volume air conditioning system

    Directory of Open Access Journals (Sweden)

    Rajagopalan Parameshwaran

    2008-01-01

    Full Text Available In the quest for energy conservative building design, there is now a great opportunity for a flexible and sophisticated air conditioning system capable of addressing better thermal comfort, indoor air quality, and energy efficiency, that are strongly desired. The variable refrigerant volume air conditioning system provides considerable energy savings, cost effectiveness and reduced space requirements. Applications of intelligent control like fuzzy logic controller, especially adapted to variable air volume air conditioning systems, have drawn more interest in recent years than classical control systems. An experimental analysis was performed to investigate the inherent operational characteristics of the combined variable refrigerant volume and variable air volume air conditioning systems under fixed ventilation, demand controlled ventilation, and combined demand controlled ventilation and economizer cycle techniques for two seasonal conditions. The test results of the variable refrigerant volume and variable air volume air conditioning system for each techniques are presented. The test results infer that the system controlled by fuzzy logic methodology and operated under the CO2 based mechanical ventilation scheme, effectively yields 37% and 56% per day of average energy-saving in summer and winter conditions, respectively. Based on the experimental results, the fuzzy based combined system can be considered to be an alternative energy efficient air conditioning scheme, having significant energy-saving potential compared to the conventional constant air volume air conditioning system.

  19. Design report on the guide box-reactivity and safety control plates for MPR reactor under normal operation conditions

    International Nuclear Information System (INIS)

    Markiewicz, M.

    1999-01-01

    The reactivity control system for the MPR reactor (Multi Purpose Reactor) is a critical component regarding safety, it must ensure a fast shut down, maintaining the reactor in subcritical condition under normal or accidental operation condition. For this purpose, this core component must be designed to maintain its operating capacity during all the residence time and under any foreseen operation condition. The mechanical design of control plates and guide boxes must comply with structural integrity, maintaining its geometric and dimensional stability within the pre-established limits to prevent interferences with other core components. For this, the heat generation effect, mechanical loads and environment and irradiation effects were evaluated during the mechanical design. The reactivity control system is composed of guide boxes, manufactured from Aluminium alloy, located between the fuel elements, and control absorber plates of Ag-In-Cd alloy hermetically enclosed by a cladding of stainless steel sliding inside de guide boxes. The upward-downward movement is transmitted by a rod from the motion device located at the reactor lower part. The design requirements, criteria and limits were established to fulfill with the normal and abnormal operation conditions. The design verifications were performed by analytical method, estimating the guide box and control plates residence time. The result of the analysis performed, shows that the design of the reactivity control system and the material selected, are appropriate to fulfill the functional requirements, with no failures attributed to the mechanical design. (author)

  20. Active Control of Low-Speed Fan Tonal Noise Using Actuators Mounted in Stator Vanes: Part III Results

    Science.gov (United States)

    Sutliff, Daniel L.; Remington, Paul J.; Walker, Bruce E.

    2003-01-01

    A test program to demonstrate simplification of Active Noise Control (ANC) systems relative to standard techniques was performed on the NASA Glenn Active Noise Control Fan from May through September 2001. The target mode was the m = 2 circumferential mode generated by the rotor-stator interaction at 2BPF. Seven radials (combined inlet and exhaust) were present at this condition. Several different error-sensing strategies were implemented. Integration of the error-sensors with passive treatment was investigated. These were: (i) an in-duct linear axial array, (ii) an induct steering array, (iii) a pylon-mounted array, and (iv) a near-field boom array. The effect of incorporating passive treatment was investigated as well as reducing the actuator count. These simplified systems were compared to a fully ANC specified system. Modal data acquired using the Rotating Rake are presented for a range of corrected fan rpm. Simplified control has been demonstrated to be possible but requires a well-known and dominant mode signature. The documented results here in are part III of a three-part series of reports with the same base title. Part I and II document the control system and error-sensing design and implementation.

  1. Model Predictive Control of the Exit Part Temperature for an Austenitization Furnace

    Directory of Open Access Journals (Sweden)

    Hari S. Ganesh

    2016-12-01

    Full Text Available Quench hardening is the process of strengthening and hardening ferrous metals and alloys by heating the material to a specific temperature to form austenite (austenitization, followed by rapid cooling (quenching in water, brine or oil to introduce a hardened phase called martensite. The material is then often tempered to increase toughness, as it may decrease from the quench hardening process. The austenitization process is highly energy-intensive and many of the industrial austenitization furnaces were built and equipped prior to the advent of advanced control strategies and thus use large, sub-optimal amounts of energy. The model computes the energy usage of the furnace and the part temperature profile as a function of time and position within the furnace under temperature feedback control. In this paper, the aforementioned model is used to simulate the furnace for a batch of forty parts under heuristic temperature set points suggested by the operators of the plant. A model predictive control (MPC system is then developed and deployed to control the the part temperature at the furnace exit thereby preventing the parts from overheating. An energy efficiency gain of 5.3 % was obtained under model predictive control compared to operation under heuristic temperature set points tracked by a regulatory control layer.

  2. Design of automatic control system of temperature in radon chamber controlled by air-condition based on 485 BUS

    International Nuclear Information System (INIS)

    Man Zaigang; Wang Renbo; Zhang Xiongjie; Zhu Zhifu; Tang Bin

    2009-01-01

    Radon chamber can be widely used in various radon measurement instruments for calibration, testing and radon environment experiment. According to requisition, radon chamber temperature should be controllable from +10 degree C to +30 degree C, and the temperature control accuracy of the system reaches ±1 degree C. The design of automatic temperature controlled by air-condition based on 485 BUS is introduced. The software and hardware techniques of how the ATMEL89S52 micro controller controls air-condition and communicates with computer are elaborated on. (authors)

  3. Technical Requirements and Principles for the Standards Development of the Key Parts for Rotor Air-conditioning Compressors

    Institute of Scientific and Technical Information of China (English)

    Sun Min; Wen Yun; Fan Zhangzeng

    2011-01-01

    ntroductionSince 2000,air-conditioning sales continues to grow,and the development of air-conditioning market makes a booming market of compressor.At the present time,compressor production rising all the way,and the sales steps up the new steps constantly.Tendency chart is shown in figure 1.Rotor compressor with its simple structure,small volume,light weight,easy processed mechanical parts,reliable operation and other excellent characteristics occupied the dominant position in the market.Compared with reciprocating compressor on the same application situation,decreased in the size by 40%~50%,weight was reduced by 40%~50%.But there were also disadvantages,mainly large friction loss,friction power consumption was about 10%of compressor's total power input.

  4. Real Time Part Input Control of a Pull Production System by Finding IF-THEN Rules

    Science.gov (United States)

    Ramli, Rizauddin; Yamamoto, Hidehiko; Abu Qudeiri, Jaber

    This paper considers the part input problem of a production system where two Flexible Transfer Lines (FTLs) consisting of an up-stream production line and a down-stream production line while operating under Just In Time (JIT) production management. The up-stream production line processes the raw material after receiving them from suppliers, and after processing them, delivers the processed product to a down-stream production line via a conveyer. In this paper, we have proposed a novel idea for a part input real time control system, known as Algorithm for Real Time Control of Part Input Systems (ARTCOPS). The algorithm is useful when FTLs are in operation under a production order that is different from the pre-decided production schedule. Simulations of virtual production systems have been carried out to verify that ARTCOPS is useful in real time control, although the production orders are different from the pre-decided production scheduling.

  5. Decadal variability of drought conditions over the southern part of Europe based on Principal Oscillation Pattern Analysis

    Science.gov (United States)

    Ionita-Scholz, Monica; Tallaksen, Lena M.; Scholz, Patrick

    2017-04-01

    This study introduces a novel method of estimating the decay time, mean period and forcing statistics of drought conditions over large spatial domains, demonstrated here for southern part of Europe (10°E - 40°E, 35°N - 50°N). It uses a two-dimensional stochastically forced damped linear oscillator model with the model parameters estimated from a Principal Oscillation Pattern (POP) analysis and associated observed power spectra. POP is a diagnostic technique that aims to derive the space-time characteristics of a data set objectively. This analysis is performed on an extended observational time series of 114 years (1902 - 2015) of the Standardized Precipitation Evapotranspiration Index for an accumulation period of 12 months (SPEI12), based on the Climate Research Unit (CRU TS v. 3.24) data set. The POP analysis reveals four exceptionally stable modes of variability, which together explain more than 62% of the total explained variance. The most stable POP mode, which explains 16.3% of the total explained variance, is characterized by a period of oscillation of 14 years and a decay time of 31 years. The real part of POP1 is characterized by a monopole-like structure with the highest loadings over Portugal, western part of Spain and Turkey. The second stable mode, which explains 15.9% of the total explained variance, is characterized by a period of oscillation of 20 years and a decay time of 26.4 years. The spatial structure of the real part of POP2 has a dipole-like structure with the highest positive loadings over France, southern Germany and Romania and negative loadings over southern part of Spain. The third POP mode, in terms of stability, explains 14.0% of the total variance and is characterized by a period of oscillation of 33 years and a decay time of 43.5 years. The real part of POP3 is characterized by negative loadings over the eastern part of Europe and positive loadings over Turkey. The fourth stable POP mode, explaining 15.5% of the total variance

  6. Social proof in the supermarket : Promoting healthy choices under low self-control conditions

    NARCIS (Netherlands)

    Salmon, Stefanie J.; De Vet, Emely; Adriaanse, Marieke A.; Fennis, Bob M.; Veltkamp, Martijn; De Ridder, Denise T. D.

    2015-01-01

    Under low self-control conditions, people often favor tempting but unhealthy food products. Instead of fighting against low self-control to reduce unhealthy food choices, we aim to demonstrate in a field study that heuristic decision tendencies can be exploited under these conditions. To do so a

  7. Social proof in the supermarket: Promoting healthy choices under low self-control conditions

    NARCIS (Netherlands)

    Salmon, S.J.; Vet, de E.; Adriaanse, M.A.; Fennis, B.M.; Veltkamp, M.; Ridder, de D.T.D.

    2015-01-01

    Under low self-control conditions, people often favor tempting but unhealthy food products. Instead of fighting against low self-control to reduce unhealthy food choices, we aim to demonstrate in a field study that heuristic decision tendencies can be exploited under these conditions. To do so a

  8. Experimental Study on Intelligent Control Scheme for Fan Coil Air-Conditioning System

    Directory of Open Access Journals (Sweden)

    Yanfeng Li

    2013-01-01

    Full Text Available An intelligent control scheme for fan coil air-conditioning systems has been put forward in order to overcome the shortcomings of the traditional proportion-integral-derivative (PID control scheme. These shortcomings include the inability of anti-interference and large inertia. An intelligent control test rig of fan coil air-conditioning system has been built, and MATLAB/Simulink dynamics simulation software has been adopted to implement the intelligent control scheme. A software for data exchange has been developed to combine the intelligence control system and the building automation (BA system. Experimental tests have been conducted to investigate the effectiveness of different control schemes including the traditional PID control, fuzzy control, and fuzzy-PID control for fan coil air-conditioning system. The effects of control schemes have been compared and analyzed in robustness, static and dynamic character, and economy. The results have shown that the developed data exchange interface software can induce the intelligent control scheme of the BA system more effectively. Among the proposed control strategies, fuzzy-PID control scheme which has the advantages of both traditional PID and fuzzy schemes is the optimal control scheme for the fan coil air-conditioning system.

  9. An Optimal Integrated Control Scheme for Permanent Magnet Synchronous Generator-Based Wind Turbines under Asymmetrical Grid Fault Conditions

    Directory of Open Access Journals (Sweden)

    Dan Wang

    2016-04-01

    Full Text Available In recent years, the increasing penetration level of wind energy into power systems has brought new issues and challenges. One of the main concerns is the issue of dynamic response capability during outer disturbance conditions, especially the fault-tolerance capability during asymmetrical faults. In order to improve the fault-tolerance and dynamic response capability under asymmetrical grid fault conditions, an optimal integrated control scheme for the grid-side voltage-source converter (VSC of direct-driven permanent magnet synchronous generator (PMSG-based wind turbine systems is proposed in this paper. The optimal control strategy includes a main controller and an additional controller. In the main controller, a double-loop controller based on differential flatness-based theory is designed for grid-side VSC. Two parts are involved in the design process of the flatness-based controller: the reference trajectories generation of flatness output and the implementation of the controller. In the additional control aspect, an auxiliary second harmonic compensation control loop based on an improved calculation method for grid-side instantaneous transmission power is designed by the quasi proportional resonant (Quasi-PR control principle, which is able to simultaneously restrain the second harmonic components in active power and reactive power injected into the grid without the respective calculation for current control references. Moreover, to reduce the DC-link overvoltage during grid faults, the mathematical model of DC-link voltage is analyzed and a feedforward modified control factor is added to the traditional DC voltage control loop in grid-side VSC. The effectiveness of the optimal control scheme is verified in PSCAD/EMTDC simulation software.

  10. Influence of upstream disturbance on the draft-tube flow of Francis turbine under part-load conditions

    Science.gov (United States)

    Chen, Ting; Zheng, Xianghao; Zhang, Yu-ning; Li, Shengcai

    2018-02-01

    Owing to the part-load operations for the enhancement of grid flexibility, the Francis turbine often suffers from severe low-frequency and large-amplitude hydraulic instability, which is mostly pertinent to the highly unsteady swirling vortex rope in the draft tube. The influence of disturbances in the upstream (e.g., large-scale vortex structures in the spiral casing) on the draft-tube vortex flow is not well understood yet. In the present paper, the influence of the upstream disturbances on the vortical flow in the draft tube is studied based on the vortex identification method and the analysis of several important parameters (e.g., the swirl number and the velocity profile). For a small guide vane opening (representing the part-load condition), the vortices triggered in the spiral casing propagate downstream and significantly affect the swirling vortex-rope precession in the draft tube, leading to the changes of the intensity and the processional frequency of the swirling vortex rope. When the guide vane opening approaches the optimum one (representing the full-load condition), the upstream disturbance becomes weaker and thus its influences on the downstream flow are very limited.

  11. Some problems of control of dynamical conditions of technological vibrating machines

    Science.gov (United States)

    Kuznetsov, N. K.; Lapshin, V. L.; Eliseev, A. V.

    2017-10-01

    The possibility of control of dynamical condition of the shakers that are designed for vibration treatment of parts interacting with granular media is discussed. The aim of this article is to develop the methodological basis of technology of creation of mathematical models of shake tables and the development of principles of formation of vibrational fields, estimation of their parameters and control of the structure vibration fields. Approaches to build mathematical models that take into account unilateral constraints, the relationships between elements, with the vibrating surface are developed. Methods intended to construct mathematical model of linear mechanical oscillation systems are used. Small oscillations about the position of static equilibrium are performed. The original method of correction of vibration fields by introduction of the oscillating system additional ties to the structure are proposed. Additional ties are implemented in the form of a mass-inertial device for changing the inertial parameters of the working body of the vibration table by moving the mass-inertial elements. The concept of monitoring the dynamic state of the vibration table based on the original measuring devices is proposed. Estimation for possible changes in dynamic properties is produced. The article is of interest for specialists in the field of creation of vibration technology machines and equipment.

  12. Mental skills training effectively minimizes operative performance deterioration under stressful conditions: Results of a randomized controlled study.

    Science.gov (United States)

    Anton, N E; Beane, J; Yurco, A M; Howley, L D; Bean, E; Myers, E M; Stefanidis, D

    2018-02-01

    Stress can negatively impact surgical performance, but mental skills may help. We hypothesized that a comprehensive mental skills curriculum (MSC) would minimize resident performance deterioration under stress. Twenty-four residents were stratified then randomized to receive mental skills and FLS training (MSC group), or only FLS training (control group). Laparoscopic suturing skill was assessed on a live porcine model with and without external stressors. Outcomes were compared with t-tests. Twenty-three residents completed the study. The groups were similar at baseline. There were no differences in suturing at posttest or transfer test under normal conditions. Both groups experienced significantly decreased performance when stress was applied, but the MSC group significantly outperformed controls under stress. This MSC enabled residents to perform significantly better than controls in the simulated OR under unexpected stressful conditions. These findings support the use of psychological skills as an integral part of a surgical resident training. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Modelling and Control of Ionic Electroactive Polymer Actuators under Varying Humidity Conditions

    Directory of Open Access Journals (Sweden)

    S. Sunjai Nakshatharan

    2018-02-01

    Full Text Available In this work, we address the problem of position control of ionic electroactive polymer soft actuators under varying relative humidity conditions. The impact of humidity on the actuation performance of ionic actuators is studied through frequency response and impedance spectroscopy analysis. Considering the uncertain performance of the actuator under varying humidity conditions, an adaptable model using the neural network method is developed. The model uses relative humidity magnitude as one of the model parameters, making it robust to different environmental conditions. Utilizing the model, a closed-loop controller based on the model predictive controller is developed for position control of the actuator. The developed model and controller are experimentally verified and found to be capable of predicting and controlling the actuators with excellent tracking accuracy under relative humidity conditions varying in the range of 10–90%.

  14. Intelligent energy management control of vehicle air conditioning system coupled with engine

    International Nuclear Information System (INIS)

    Khayyam, Hamid; Abawajy, Jemal; Jazar, Reza N.

    2012-01-01

    Vehicle Air Conditioning (AC) systems consist of an engine powered compressor activated by an electrical clutch. The AC system imposes an extra load to the vehicle's engine increasing the vehicle fuel consumption and emissions. Energy management control of the vehicle air conditioning is a nonlinear dynamic system, influenced by uncertain disturbances. In addition, the vehicle energy management control system interacts with different complex systems, such as engine, air conditioning system, environment, and driver, to deliver fuel consumption improvements. In this paper, we describe the energy management control of vehicle AC system coupled with vehicle engine through an intelligent control design. The Intelligent Energy Management Control (IEMC) system presented in this paper includes an intelligent algorithm which uses five exterior units and three integrated fuzzy controllers to produce desirable internal temperature and air quality, improved fuel consumption, low emission, and smooth driving. The three fuzzy controllers include: (i) a fuzzy cruise controller to adapt vehicle cruise speed via prediction of the road ahead using a Look-Ahead system, (ii) a fuzzy air conditioning controller to produce desirable temperature and air quality inside vehicle cabin room via a road information system, and (iii) a fuzzy engine controller to generate the required engine torque to move the vehicle smoothly on the road. We optimised the integrated operation of the air conditioning and the engine under various driving patterns and performed three simulations. Results show that the proposed IEMC system developed based on Fuzzy Air Conditioning Controller with Look-Ahead (FAC-LA) method is a more efficient controller for vehicle air conditioning system than the previously developed Coordinated Energy Management Systems (CEMS). - Highlights: ► AC interacts: vehicle, environment, driver components, and the interrelationships between them. ► Intelligent AC algorithm which uses

  15. Linear parameter varying control of wind turbines covering both partial load and full load conditions

    DEFF Research Database (Denmark)

    Østergaard, Kasper Zinck; Stoustrup, Jakob; Brath, Per

    2009-01-01

    operations tend to be ill-conditioned. The paper proposes a controller construction algorithm together with various remedies for improving the numerical conditioning the algorithm.The proposed algorithm is applied to the design of a LPV controller for wind turbines, and a comparison is made with a controller...... designed using classical techniques to conclude that an improvement in performance is obtained for the entire operating envelope....

  16. Use of statistic control of the process as part of a quality assurance plan; Empleo del control estadistico de proceso como parte de un plan de aseguramiento de la calidad

    Energy Technology Data Exchange (ETDEWEB)

    Acosta, S.; Lewis, C., E-mail: sacosta@am.gob.ar [Autoridad Regulatoria Nuclear (ARN), Buenos Aires (Argentina)

    2013-07-01

    One of the technical requirements of the standard IRAM ISO 17025 for the accreditation of testing laboratories, is the assurance of the quality of the results through the control and monitoring of the factors influencing the reliability of them. The grade the factors contribute to the total measurement uncertainty, determines which of them should be considered when developing a quality assurance plan. The laboratory of environmental measurements of strontium-90 in the accreditation process, performs most of its determinations in samples with values close to the detection limit. For this reason the correct characterization of the white, is a critical parameter and is verified through a letter for statistical process control. The scope of the present work is concerned the control of whites and so it was collected a statistically significant amount of data, for a period of time that is covered of different conditions. This allowed consider significant variables in the process, such as temperature and humidity, and build a graph of white control, which forms the basis of a statistical process control. The data obtained were lower and upper limits for the preparation of the charter white control. In this way the process of characterization of white was considered to operate under statistical control and concludes that it can be used as part of a plan of insurance of the quality.

  17. 76 FR 31456 - Special Conditions: Gulfstream Model GVI Airplane; Electronic Flight Control System: Control...

    Science.gov (United States)

    2011-06-01

    ... electronic flight control system. The applicable airworthiness regulations do not contain adequate or... Design Features The Gulfstream Model GVI airplane has an electronic flight control system and no direct... impending control surface limiting, piloted or auto-flight system control of the airplane might be...

  18. 76 FR 9265 - Special Conditions: Gulfstream Model GVI Airplane; Electronic Flight Control System: Control...

    Science.gov (United States)

    2011-02-17

    ...: Gulfstream Model GVI Airplane; Electronic Flight Control System: Control Surface Position Awareness AGENCY... for transport category airplanes. These design features include an electronic flight control system... Design Features The GVI has an electronic flight control system and no direct coupling from the cockpit...

  19. A ballistics module as a part of the fire control system

    Directory of Open Access Journals (Sweden)

    Branka R. Luković

    2013-10-01

    Full Text Available This article presents a ballistics module as a part of the fire control system of weapons for fire support (mortars, artillery weapons and rocket launchers. The software is "open" with the prominence of autonomy work. It can be modulated and adapted on the user demand. Moreover, it is independent of the hardware base. Introduction: The fire control system is based on a ballistic module (BM which determines the firing data for each weapon tool in the battery. Ballistic calculations, for the given position of the target in relation to the position of tools in the given weather conditions, determine firing data (elevation, direction, timing and locating devices so that the missile seems to cause the desired effect. This paper gives the basic information about the features the BM performs and the manner of their implementation in the fire control system without going into algorithmic solution procedures. Ballistic problem in the fire control system: Ballistic calculation is based on a trajectory calculation of all kinds of projectiles (current, time-fuze, illuminating, smoke, with conventional propulsion, rocket, with built-in gas generator, etc.. Instead of previous solutions, where a trajectory calculation of the fire control system was done by approximate methods, in this BM the trajectory calculation is made by the same model with the same data as for a weapon and ammunition in the process of creating a firing table. The data used in the fire control system are made simultaneously with the preparation of firing tables for a particular tool and associated ammunition,. A modified model of particle, standardized at the NATO level, is also used. Taking into account the meteorological situation, before the trajectory calculation is done, a relative position of the target in relation to the position of the tool should be determined. A selection or loading check is carried out (possibility of reaching a given target as well as the point at which the

  20. Space and Missile Systems Center Standard: Parts, Materials, and Processes Control Program for Space Vehicles

    Science.gov (United States)

    2013-04-12

    preparation , implementation, and operation of a Parts, Materials, and Processes (PMP) control program for use during the design, development...Processes List CDR Critical Design Review CDRL Contract Data Requirements List CMOS Complementary Metal Oxide Semiconductor CONOPS Concept of Operations...Failure Review Board GFE Government Furnished Equipment GIDEP Government Industry Data Exchange Program HBT Heterojunction Bipolar Transistor IPT

  1. Document control system as an integral part of RA documentation database application

    International Nuclear Information System (INIS)

    Steljic, M.M; Ljubenov, V.Lj. . E-mail address of corresponding author: milijanas@vin.bg.ac.yu; Steljic, M.M.)

    2005-01-01

    The decision about the final shutdown of the RA research reactor in Vinca Institute has been brought in 2002, and therefore the preparations for its decommissioning have begun. All activities are supervised by the International Atomic Energy Agency (IAEA), which also provides technical and experts' support. This paper describes the document control system is an integral part of the existing RA documentation database. (author)

  2. Controlling Relations in Baseline Conditional Discriminations as Determinants of Stimulus Equivalence

    Science.gov (United States)

    de Rose, Julio C.; Hidalgo, Matheus; Vasconcellos, Mariliz

    2013-01-01

    Variation in baseline controlling relations is suggested as one of the factors determining variability in stimulus equivalence outcomes. This study used single- comparison trials attempting to control such controlling relations. Four children learned AB, BC, and CD conditional discriminations, with 2 samples and 2 comparison stimuli. In Condition…

  3. Vector-valued measure and the necessary conditions for the optimal control problems of linear systems

    International Nuclear Information System (INIS)

    Xunjing, L.

    1981-12-01

    The vector-valued measure defined by the well-posed linear boundary value problems is discussed. The maximum principle of the optimal control problem with non-convex constraint is proved by using the vector-valued measure. Especially, the necessary conditions of the optimal control of elliptic systems is derived without the convexity of the control domain and the cost function. (author)

  4. Controllable conditional quantum oscillations and quantum gate operations in superconducting flux qubits

    International Nuclear Information System (INIS)

    Chen Aimin; Cho Samyoung

    2011-01-01

    Conditional quantum oscillations are investigated for quantum gate operations in superconducting flux qubits. We present an effective Hamiltonian which describes a conditional quantum oscillation in two-qubit systems. Rabi-type quantum oscillations are discussed in implementing conditional quantum oscillations to quantum gate operations. Two conditional quantum oscillations depending on the states of control qubit can be synchronized to perform controlled-gate operations by varying system parameters. It is shown that the conditional quantum oscillations with their frequency synchronization make it possible to operate the controlled-NOT and -U gates with a very accurate gate performance rate in interacting qubit systems. Further, this scheme can be applicable to realize a controlled multi-qubit operation in various solid-state qubit systems. (author)

  5. Pointwise second-order necessary optimality conditions and second-order sensitivity relations in optimal control

    Science.gov (United States)

    Frankowska, Hélène; Hoehener, Daniel

    2017-06-01

    This paper is devoted to pointwise second-order necessary optimality conditions for the Mayer problem arising in optimal control theory. We first show that with every optimal trajectory it is possible to associate a solution p (ṡ) of the adjoint system (as in the Pontryagin maximum principle) and a matrix solution W (ṡ) of an adjoint matrix differential equation that satisfy a second-order transversality condition and a second-order maximality condition. These conditions seem to be a natural second-order extension of the maximum principle. We then prove a Jacobson like necessary optimality condition for general control systems and measurable optimal controls that may be only ;partially singular; and may take values on the boundary of control constraints. Finally we investigate the second-order sensitivity relations along optimal trajectories involving both p (ṡ) and W (ṡ).

  6. Production and quality control of concrete for the Rajasthan Atomic Power Station - [Part 2

    International Nuclear Information System (INIS)

    Singh Roy, P.K.; Sukhtankar, K.D.; Prasad, K.

    1975-01-01

    The following aspects of the production and quality control of concrete and concrete materials used in the construction of twin-reactor Rajasthan Atomic Power Station are discussed : (1) relationship between strength of cubes and cylinders made of concrete used for the prestressed dome (2) temperature control during pouring of concrete (3) thermal conductivity of heavy concrete (4) various types of grouting procedures used for different structures forming part of reactors (5) quality control of normal and heavy concrete and (6) leakage through form ties. Typical concrete mixes used for grouts are also given. (M.G.B.)

  7. Transducer placement for robustness to variations in boundary conditions for active structural acoustic control

    Science.gov (United States)

    Sprofera, Joseph D.; Clark, Robert L.; Cabell, Randolph H.; Gibbs, Gary P.

    2005-05-01

    Turbulent boundary layer (TBL) noise is considered a primary contribution to the interior noise present in commercial airliners. There are numerous investigations of interior noise control devoted to aircraft panels; however, practical realization is a potential challenge since physical boundary conditions are uncertain at best. In most prior studies, pinned or clamped boundary conditions were assumed; however, realistic panels likely display a range of boundary conditions between these two limits. Uncertainty in boundary conditions is a challenge for control system designers, both in terms of the compensator implemented and the location of transducers required to achieve the desired control. The impact of model uncertainties, specifically uncertain boundaries, on the selection of transducer locations for structural acoustic control is considered herein. The final goal of this work is the design of an aircraft panel structure that can reduce TBL noise transmission through the use of a completely adaptive, single-input, single-output control system. The feasibility of this goal is demonstrated through the creation of a detailed analytical solution, followed by the implementation of a test model in a transmission loss apparatus. Successfully realizing a control system robust to variations in boundary conditions can lead to the design and implementation of practical adaptive structures that could be used to control the transmission of sound to the interior of aircraft. Results from this research effort indicate it is possible to optimize the design of actuator and sensor location and aperture, minimizing the impact of boundary conditions on the desired structural acoustic control.

  8. Hydrologic and water-quality conditions in the lower Apalachicola-Chattahoochee-Flint and parts of the Aucilla-Suwannee-Ochlockonee River basins in Georgia and adjacent parts of Florida and Alabama during drought conditions, July 2011

    Science.gov (United States)

    Gordon, Debbie W.; Peck, Michael F.; Painter, Jaime A.

    2012-01-01

    As part of the U.S. Department of the Interior sustainable water strategy, WaterSMART, the U.S. Geological Survey documented hydrologic and water-quality conditions in the lower Apalachicola-Chattahoochee-Flint and western and central Aucilla-Suwannee-Ochlockonee River basins in Alabama, Florida, and Georgia during low-flow conditions in July 2011. Moderate-drought conditions prevailed in this area during early 2011 and worsened to exceptional by June, with cumulative rainfall departures from the 1981-2010 climate normals registering deficits ranging from 17 to 27 inches. As a result, groundwater levels and stream discharges measured below median daily levels throughout most of 2011. Water-quality field properties including temperature, dissolved oxygen, specific conductance, and pH were measured at selected surface-water sites. Record-low groundwater levels measured in 12 of 43 surficial aquifer wells and 128 of 312 Upper Floridan aquifer wells during July 2011 underscored the severity of drought conditions in the study area. Most wells recorded groundwater levels below the median daily statistic, and 7 surficial aquifer wells were dry. Groundwater-level measurements taken in July 2011 were used to determine the potentiometric surface of the Upper Floridan aquifer. Groundwater generally flows to the south and toward streams except in reaches where streams discharge to the aquifer. The degree of connection between the Upper Floridan aquifer and streams decreases east of the Flint River where thick overburden hydraulically separates the aquifer from stream interaction. Hydraulic separation of the Upper Floridan aquifer from streams located east of the Flint River is shown by stream-stage altitudes that differ from groundwater levels measured in close proximity to streams. Most streams located in the study area during 2011 exhibited below normal flows (streamflows less than the 25th percentile), substantiating the severity of drought conditions that year. Streamflow

  9. Sufficient Controllability Condition for Affine Systems with Two-Dimensional Control and Two-Dimensional Zero Dynamics

    Directory of Open Access Journals (Sweden)

    D. A. Fetisov

    2015-01-01

    Full Text Available The controllability conditions are well known if we speak about linear stationary systems: a linear stationary system is controllable if and only if the dimension of the state vector is equal to the rank of the controllability matrix. The concept of the controllability matrix is extended to affine systems, but relations between affine systems controllability and properties of this matrix are more complicated. Various controllability conditions are set for affine systems, but they deal as usual either with systems of some special form or with controllability in some small neighborhood of the concerned point. An affine system is known to be controllable if the system is equivalent to a system of a canonical form, which is defined and regular in the whole space of states. In this case, the system is said to be feedback linearizable in the space of states. However there are examples, which illustrate that a system can be controllable even if it is not feedback linearizable in any open subset in the space of states. In this article we deal with such systems.Affine systems with two-dimensional control are considered. The system in question is assumed to be equivalent to a system of a quasicanonical form with two-dimensional zero dynamics which is defined and regular in the whole space of states. Therefore the controllability of the original system is equivalent to the controllability of the received system of a quasicanonical form. In this article the sufficient condition for an available solution of the terminal problem is proven for systems of a quasicanonical form with two-dimensional control and two-dimensional zero dynamics. The condition is valid in the case of an arbitrary time interval and arbitrary initial and finite states of the system. Therefore the controllability condition is set for systems of a quasicanonical form with two-dimensional control and two-dimensional zero dynamics. An example is given which illustrates how the proved

  10. Controlled production of Camembert-type cheeses. Part I: Microbiological and physicochemical evolutions.

    Science.gov (United States)

    Leclercq-Perlat, Marie-Noëlle; Buono, Frédéric; Lambert, Denis; Latrille, Eric; Spinnler, Henry-Eric; Corrieu, Georges

    2004-08-01

    A holistic approach of a mould cheese ripening is presented. The objective was to establish relationships between the different microbiological and biochemical changes during cheese ripening. Model cheeses were prepared from pasteurized milk inoculated with Kluyveromyces lactis, Geotrichum candidum, Penicillium camemberti and Brevibacterium linens under aseptic conditions. Two cheese-making trials with efficient control of environmental parameters were carried out and showed similar ripening characteristics. K. lactis grew rapidly between days 1 and 6 (generation time around 48 h). G. candidum grew exponentially between days 4 and 10 (generation time around 4.6 d). Brevi. linens also grew exponentially but after day 6 when Pen. camemberti mycelium began developing and the pH of the rind was close to 7. Its exponential growth presented 3 phases in relation to carbon and nitrogen substrate availability. Concentrations of Pen. camemberti mycelium were not followed by viable cell count but they were evaluated visually. The viable microorganism concentrations were well correlated with the carbon substrate concentrations in the core and in the rind. The lactose concentrations were negligible after 10 d ripening, and changes in lactate quantities were correlated with fungi flora. The pH of the inner part depended on NH3. Surface pH was significantly related to NH3 concentration and to fungi growth. The acid-soluble nitrogen (ASN) and non-protein nitrogen (NPN) indexes and NH3 concentrations of the rind were low until day 6, and then increased rapidly to follow the fungi concentrations until day 45. The ASN and NPN indexes and NH3 concentrations in the core were lower than in the rind and they showed the same evolution. G. candidum and Pen. camemberti populations have a major effect on proteolysis; nevertheless, K. lactis and Brevi. linens cell lysis also had an impact on proteolysis. Viable cell counts of K. lactis, G. candidum, Pen. camemberti and Brevi. linens were

  11. Experimental study of a novel capacity control algorithm for a multi-evaporator air conditioning system

    International Nuclear Information System (INIS)

    Xu Xiangguo; Pan Yan; Deng Shiming; Xia Liang; Chan Mingyin

    2013-01-01

    The use of a multi-evaporator air conditioning (MEAC) system is advantageous in terms of installation convenience, high design flexibility, being easy to maintain and commission, better indoor thermal comfort control and higher energy efficiency. While MEAC units worth billions of dollars are sold worldwide, the detailed accounts on compressor capacity control and refrigeration flow distribution amongst evaporators remain unavailable in public domain, mainly due to commercial confidentiality. Limited control algorithms for MEAC systems have been developed based on system simulation, and no experimental-based capacity controller developments and their controllability tests may be identified in open literature. In the study reported in this paper, a novel capacity control algorithm, which imitated On–Off control of a single evaporator air conditioning (A/C) system in each indoor unit of a MEAC system by using variable speed compressor and electronic expansion valves (EEVs), was developed. Controllability tests under various settings for experimentally validating the novel capacity control algorithm were carried out and the control algorithm was further improved based on the experimental results. - Highlights: ► A capacity control algorithm for a multi-evaporator air conditioning system was developed. ► Experimental controllability tests under various settings were carried out. ► The control algorithm was further improved based on the experimental results.

  12. Cervical Joint Position Sense in Hypobaric Conditions: A Randomized Double-Blind Controlled Trial.

    Science.gov (United States)

    Bagaianu, Diana; Van Tiggelen, Damien; Duvigneaud, N; Stevens, Veerle; Schroyen, Danny; Vissenaeken, Dirk; D'Hondt, Gino; Pitance, Laurent

    2017-09-01

    head repositioning accuracy in healthy subjects. Discussion/impact/recommendations: Postural control mechanisms are very sensitive to acute mild hypoxia and have been recently investigated. Acute hypobaric hypoxia at moderate and high altitudes has a negative effect on postural control. However, which part of the postural system is affected has not yet been determined and proprioception has been little investigated. The results from this study highlighted that in healthy subjects with good cervical spine proprioception at baseline, artificial hypoxia induced by the simulation of moderate altitude does not increase head repositioning error. Further studies should investigate cervical joint position sense in real aircraft, at different altitudes and in a group of experienced helicopter pilots, to evaluate the impact of moderate altitude on cervical joint position sense in a different population. Conducting the same experiments in a population of pilots and in real flight conditions should be considered, since various factors such as the level of proprioception, head posture, type of movement, head load, muscle fatigue, flight altitude, and the length of flight time might influence the kinesthetic sensitivity. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.

  13. Experimental evidence of inter-blade cavitation vortex development in Francis turbines at deep part load condition

    Science.gov (United States)

    Yamamoto, K.; Müller, A.; Favrel, A.; Avellan, F.

    2017-10-01

    Francis turbines are subject to various types of cavitation flow depending on the operating condition. To enable a smooth integration of the renewable energy sources, hydraulic machines are now increasingly required to extend their operating range, especially down to extremely low discharge conditions called deep part load operation. The inter-blade cavitation vortex is a typical cavitation phenomenon observed at deep part load operation. However, its dynamic characteristics are insufficiently understood today. In an objective of revealing its characteristics, the present study introduces a novel visualization technique with instrumented guide vanes embedding the visualization devices, providing unprecedented views on the inter-blade cavitation vortex. The binary image processing technique enables the successful evaluation of the inter-blade cavitation vortex in the images. As a result, it is shown that the probability of the inter-blade cavitation development is significantly high close to the runner hub. Furthermore, the mean vortex line is calculated and the vortex region is estimated in the three-dimensional domain for the comparison with numerical simulation results. In addition, the on-board pressure measurements on a runner blade is conducted, and the influence of the inter-blade vortex on the pressure field is investigated. The analysis suggests that the presence of the inter-blade vortex can magnify the amplitude of pressure fluctuations especially on the blade suction side. Furthermore, the wall pressure difference between pressure and suction sides of the blade features partially low or negative values near the hub at the discharge region where the inter-blade vortex develops. This negative pressure difference on the blade wall suggests the development of a backflow region caused by the flow separation near the hub, which is closely related to the development of the inter-blade vortex. The development of the backflow region is confirmed by the numerical

  14. Japanese contributions to IAEA INTOR workshop, phase two A, part 2, chapter III: impurity control (engineering)

    International Nuclear Information System (INIS)

    Seki, Masahiro; Miki, Nobuharu; Shibutani, Yoji; Fujimura, Kaoru; Adachi, Jun-ichi; Sato, Kosuke; Fujii, Masaharu; Yamazaki, Seiichiro; Itoh, Shin-ichi.

    1985-07-01

    This report corresponds to the second half of Chapter III of Japanese contribution report to IAEA INTOR Workshop, Phase Two A, Part 2. Data base assessment are made on candidate materials for the divertor, limiter, and the first wall. Engineering trade-off studies are made for the high-recycling and low temperature conditions. The studies include material considerations, configuration, thermohydraulic and stress analysis, disruption, lifetime analysis, and tritium permeation. (author)

  15. Assessment of the State of the Art of Flight Control Technologies as Applicable to Adverse Conditions

    Science.gov (United States)

    Reveley, Mary s.; Briggs, Jeffrey L.; Leone, Karen M.; Kurtoglu, Tolga; Withrow, Colleen A.

    2010-01-01

    Literature from academia, industry, and other Government agencies was surveyed to assess the state of the art in current Integrated Resilient Aircraft Control (IRAC) aircraft technologies. Over 100 papers from 25 conferences from the time period 2004 to 2009 were reviewed. An assessment of the general state of the art in adaptive flight control is summarized first, followed by an assessment of the state of the art as applicable to 13 identified adverse conditions. Specific areas addressed in the general assessment include flight control when compensating for damage or reduced performance, retrofit software upgrades to flight controllers, flight control through engine response, and finally test and validation of new adaptive controllers. The state-of-the-art assessment applicable to the adverse conditions include technologies not specifically related to flight control, but may serve as inputs to a future flight control algorithm. This study illustrates existing gaps and opportunities for additional research by the NASA IRAC Project

  16. Information system design of inventory control spare parts maintenance (valuation class 5000) (case study: plant kw)

    Science.gov (United States)

    Fitriana, Rina; Moengin, Parwadi; Riana, Mega

    2016-02-01

    Plat KW hadn't using optimal inventory level planning yet and hadn't have an information system that well computerized. The research objective is to be able to design an information system related inventory control of spare parts maintenance. The study focused on five types of spare parts with the highest application rate during February 2013- March 2015 and included in the classification of fast on FSN analysis Grinding stones Cut 4". Cable Tie 15". Welding RB 26-32MM. Ring Plat ½" and Ring Plate 5/8 ". Inventory calculation used Economic Order Quantity (EOQ). Safety Stock (SS) and Reorder Point (ROP) methods. System analysis conducted using the framework PIECES with the proposed inventory control system. the performance of the plant KW relating to the supply of spare parts maintenance needs can be more efficient as well as problems at the company can be answered and can perform inventory cost savings amounting Rp.267.066. A computerized information system of inventory control spare parts maintenance provides a menu that can be accessed by each departments as the user needed.

  17. Design Process Control for Improved Surface Finish of Metal Additive Manufactured Parts of Complex Build Geometry

    Directory of Open Access Journals (Sweden)

    Mikdam Jamal

    2017-12-01

    Full Text Available Metal additive manufacturing (AM is increasingly used to create complex 3D components at near net shape. However, the surface finish (SF of the metal AM part is uneven, with surface roughness being variable over the facets of the design. Standard post-processing methods such as grinding and linishing often meet with major challenges in finishing parts of complex shape. This paper reports on research that demonstrated that mass finishing (MF processes are able to deliver high-quality surface finishes (Ra and Sa on AM-generated parts of a relatively complex geometry (both internal features and external facets under select conditions. Four processes were studied in this work: stream finishing, high-energy (HE centrifuge, drag finishing and disc finishing. Optimisation of the drag finishing process was then studied using a structured design of experiments (DOE. The effects of a range of finishing parameters were evaluated and optimal parameters and conditions were determined. The study established that the proposed method can be successfully applied in drag finishing to optimise the surface roughness in an industrial application and that it is an economical way of obtaining the maximum amount of information in a short period of time with a small number of tests. The study has also provided an important step in helping understand the requirements of MF to deliver AM-generated parts to a target quality finish and cycle time.

  18. Optimality with feedback control in relativistic dynamics of a mass point. Part 1

    International Nuclear Information System (INIS)

    Blaquiere, A.; Pauchard, M.; Tahri-Yousfi, N.; Wickers, D.

    1984-01-01

    This article is an account of part of a research task currently in progress; it deals with relativistic dynamics of a mass-point from the point of view of the theory of optimal feedback control. In the first part, the theoretical frame is presented with an application to the case of special Relativity. This application shows that the way followed in this article is a natural one for approaching Wave mechanics, and that it closely parallels the way along which Louis de Broglie introduced Wave mechanics [fr

  19. Theoretical Background for the Decision-Making Process Modelling under Controlled Intervention Conditions

    Directory of Open Access Journals (Sweden)

    Bakanauskienė Irena

    2017-12-01

    Full Text Available This article is intended to theoretically justify the decision-making process model for the cases, when active participation of investing entities in controlling the activities of an organisation and their results is noticeable. Based on scientific literature analysis, a concept of controlled conditions is formulated, and using a rational approach to the decision-making process, a model of the 11-steps decision-making process under controlled intervention is presented. Also, there have been unified conditions, describing the case of controlled interventions thus providing preconditions to ensure the adequacy of the proposed decision-making process model.

  20. Necessary optimality conditions of the second oder in a stochastic optimal control problem with delay argument

    Directory of Open Access Journals (Sweden)

    Rashad O. Mastaliev

    2016-12-01

    Full Text Available The optimal control problem of nonlinear stochastic systems which mathematical model is given by Ito stochastic differential equation with delay argument is considered. Assuming that the concerned region is open for the control by the first and the second variation (classical sense of the quality functional we obtain the necessary optimality condition of the first and the second order. In the particular case we receive the stochastic analog of the Legendre—Clebsch condition and some constructively verified conclusions from the second order necessary condition. We investigate the Legendre–Clebsch conditions for the degeneration case and obtain the necessary conditions of optimality for a special control, in the classical sense.

  1. U3Si2 behavior in H2O environments: Part II, pressurized water with controlled redox chemistry

    Science.gov (United States)

    Nelson, A. T.; Migdisov, A.; Wood, E. Sooby; Grote, C. J.

    2018-03-01

    Recent interest in U3Si2 as an advanced light water reactor fuel has driven assessment of numerous properties, but characterization of its response to H2O environments is sparse in available literature. The behavior of U3Si2 in H2O containing atmospheres is investigated and presented in a two-part series of articles. This work examines the behavior of U3Si2 following exposure to pressurized H2O at temperatures from 300 to 350 °C. Testing was performed using two autoclave configurations and multiple redox conditions. Use of solid state buffers to attain a controlled water chemistry is also presented as a means to test actinide-bearing systems. Buffers were used to vary the hydrogen concentration between 1 and 30 parts per million H2. Testing included UN, U3Si5, and UO2. Both UN and U3Si5 were found to rapidly pulverize in less than 50 h at 300 °C. Uranium dioxide was included as a control for the autoclave system, and was found to be minimally impacted by exposure to pressurized water at the conditions tested for extended time periods. Testing of U3Si2 at 300 °C found reasonable stability through 30 days in 1-5 ppm H2. However, pulverization was observed following 35 days. The redox condition of testing strongly affected pulverization. Characterization of the resulting microstructures suggests that the mechanism responsible for pulverization under more strongly reducing conditions differs from that previously identified. Hydride formation is hypothesized to drive this transition. Testing performed at 350 °C resulted in rapid pulverization of U3Si2 in under 50 h.

  2. Integrating CHWs as Part of the Team Leading Diabetes Group Visits: A Randomized Controlled Feasibility Study.

    Science.gov (United States)

    Vaughan, Elizabeth M; Johnston, Craig A; Cardenas, Victor J; Moreno, Jennette P; Foreyt, John P

    2017-12-01

    Purpose The purpose of the study was to evaluate the feasibility of integrating Community Health Workers (CHWs) as part of the team leading diabetes group visits. Methods This was a randomized controlled study that integrated CHWs as part of the team leading diabetes group visits for low-income Hispanic adults (n = 50). Group visits met for 3 hours each month for a 6-month duration. Main measures included baseline and 6-month clinical outcomes (ie, A1C, lipids), concordance with 8 standard of care guidelines (ie, screens for cervical, breast, and colon cancer) from the US Preventive Task Force and American Diabetes Association, and participant acceptability. Results Compared to control participants, the intervention group resulted in significantly better clinical outcomes or guideline concordance for the following areas: target A1C levels, retinal eye exams, diabetes foot exams, mammograms, and urine microalbumin. Significantly more individuals in the control group gained weight, whereas a greater number of participants in the intervention group lost weight. Intervention participants found the group visits highly acceptable. Conclusions Integrating CHWs as part a comprehensive diabetes group visit program is a feasible and effective system-level intervention to improve glycemic control and achieve guideline concordance.

  3. Network Condition Based Adaptive Control and its Application to Power Balancing in Electrical Grids

    DEFF Research Database (Denmark)

    Pedersen, Rasmus; Findrik, Mislav; Sloth, Christoffer

    2017-01-01

    To maintain a reliable and stable power grid there must be balance between consumption and production. To achieve power balance in a system with high penetration of distributed renewable resources and flexible assets, these individual system can be coordinated through a control unit to become part...... of the power balancing effort. Such control strategies require communication networks for exchange of control loop information. In this work, we show how a congested communication network can have a dramatic impact on the control performance of such a power balancing controller. To alleviate potential...

  4. The comparison respond of braking torque control between PID and SMC controller for electric powered wheelchair descending on slope condition

    Science.gov (United States)

    Asyraf, S. M.; Heerwan, P. M.; Izhar, I. M.

    2018-04-01

    During descending on a slope, the speed of Electric Powered Wheelchair (EPW) tends to changed rapidly. Normally, most EPW is provided with mechanical braking system which transfers human pulling force of the lever creating friction at the tire. However, the task is difficult for the users are elderly or paralyses. However, even for normal user with good strength, in fear condition they tend to give sudden braking which leads to tire locking up and skidding, eventually EPW unstable. These problems will cause accident and injuries to the users if speed does not properly control. In this paper, the automated braking torque control method was proposed in EPW as alternative to solve this problem and increase the mobility and stability especially during descending on slope in other to help the user of the EPW as their daily transportation. In this research, Proportional-Integral-Derivative and Sliding Mode Control controller are compared to determine the best response for torque braking control. The rapid change of speed can be controlled by the braking torque using proposed controllers based on the desired constant speed set by the control designer. Moreover, the sudden braking that caused tire to lock up and skid can be avoided. Furthermore, result from SMC shows this controller have good time respond to maintain the speed based on desired value when descending at slope condition by controlling the braking torque compared to the PID controller.

  5. Modeling and fuzzy control of the engine coolant conditioning system in an IC engine test bed

    International Nuclear Information System (INIS)

    Mohtasebi, Seyed Saeid; Shirazi, Farzad A.; Javaheri, Ahmad; Nava, Ghodrat Hamze

    2010-01-01

    Mechanical and thermodynamical performance of internal combustion engines is significantly affected by the engine working temperature. In an engine test bed, the internal combustion engines are tested in different operating conditions using a dynamometer. It is required that the engine temperature be controlled precisely, particularly in transient states. This precise control can be achieved by an engine coolant conditioning system mainly consisting of a heat exchanger, a control valve, and a controller. In this study, constitutive equations of the system are derived first. These differential equations show the second- order nonlinear time-varying dynamics of the system. The model is validated with the experimental data providing satisfactory results. After presenting the dynamic equations of the system, a fuzzy controller is designed based on our prior knowledge of the system. The fuzzy rules and the membership functions are derived by a trial and error and heuristic method. Because of the nonlinear nature of the system the fuzzy rules are set to satisfy the requirements of the temperature control for different operating conditions of the engine. The performance of the fuzzy controller is compared with a PI one for different transient conditions. The results of the simulation show the better performance of the fuzzy controller. The main advantages of the fuzzy controller are the shorter settling time, smaller overshoot, and improved performance especially in the transient states of the system

  6. Influence of control algorithms parameters on an electromechanical converter with a secondary discrete part

    Directory of Open Access Journals (Sweden)

    Kuimov Denis

    2017-01-01

    Full Text Available An alternative configuration of a device with a secondary discrete part using a magnetic system of a similar multi-phase inductor machine and concentrated windings without an internal rotor is proposed. An algorithm of sensorless control of a motion process of a secondary discrete part is proposed. The analysis of the distribution nature of the magnetic field for various switching algorithms is carried out to reduce negative influence of the “dead” zones of the first and second order. The features of the movement process of the secondary discrete part in the working chamber of the device are considered. The results of in the electromagnetic force change affecting a ferromagnetic working element are presented, and recommendations for the application of switching algorithms are given.

  7. Aluminium-12wt% silicon coating prepared by thermal spraying technique: Part 1 optimization of spray condition based on a design of experiment

    Directory of Open Access Journals (Sweden)

    Jiansirisomboon, S.

    2006-03-01

    Full Text Available At present, thermal spray technology is used for maintenance parts of various machines in many industries. This technology can be used to improve the surface wear resistance. Therefore, this technology can significantly reduce cost of manufacturing. Al-12wt%Si alloy is an interesting and popular material used in the automotive industry. This research studies the suitable condition for spraying of Al-12wt%Si powder. This powder was sprayed by a flame spray technique onto low carbon steel substrates. The suitable conditions for spraying can be achieved by a design of experiment (DOE principle, which provided statistical data defined at 90% confidence. This research used control factors, which were oxygen flow rate, acetylene flow rate and spray distance. The satisfaction levels of these factors were set at 3 levels, i.e. low, medium and high, in order to determine suitable responses, which were hardness, thickness, wear rate and percentage volume fraction of porosity. It was found that the optimized condition for spraying Al-12wt%Si powder consisted of 38 ft3/hr (1.026 m3/hr of oxygen flow rate, 27 ft3/hr (0.729 m3/hr of acetylene flow rate and 58 mm of spray distance.

  8. Dimensional metrology for process and part quality control in micro manufacturing

    DEFF Research Database (Denmark)

    Hansen, Hans Nørgaard; Tosello, Guido; Gasparin, Stefania

    2011-01-01

    dimensions are scaled down and geometrical complexity of objects is increased, the available measurement technologies appear not sufficient. New solutions for measuring principles and instrumentation, tolerancing rules and procedures as well as traceability and calibration are necessary if micro......Micro manufacturing has gained interest over the last decade as the demand for micro mechanical components has increased. The need for dimensional metrology at micro scale is evident both in terms of quality assurance of components and products and in terms of process control. As critical...... manufacturing is to develop into industrial manufacturing solutions. In this paper the application of dimensional precision metrology to both component and process quality control will be demonstrated. The parts investigated are micro injection moulded polymer parts, typical for the field of micro manufacturing....

  9. Quality control and process capability assessment for injection-moulded micro mechanical parts

    DEFF Research Database (Denmark)

    Gasparin, Stefania; Tosello, Guido; Hansen, Hans Nørgaard

    2013-01-01

    Quality control of micro components is an increasing challenge. Smaller mechanical parts are characterized by smaller tolerance to be verified. This paper focuses on the dimensional verification of micro injection-moulded components selected from an industrial application. These parts are measured...... using an optical coordinate measuring machine, which guarantees fast surface scans suitable for inline quality control. The uncertainty assessment of the measurements is calculated and three analyses are carried out and discussed in order to investigate the influence parameters in optical coordinate...... metrology. The estimation of the total variability of the optical measurements and the instrument repeatability are reported; moreover, the measurement system capability is evaluated according to the measurement system capability indices Cg and Cgk....

  10. Tunable, Flexible and Efficient Optimization of Control Pulses for Superconducting Qubits, part II - Applications

    Science.gov (United States)

    AsséMat, Elie; Machnes, Shai; Tannor, David; Wilhelm-Mauch, Frank

    In part I, we presented the theoretic foundations of the GOAT algorithm for the optimal control of quantum systems. Here in part II, we focus on several applications of GOAT to superconducting qubits architecture. First, we consider a control-Z gate on Xmons qubits with an Erf parametrization of the optimal pulse. We show that a fast and accurate gate can be obtained with only 16 parameters, as compared to hundreds of parameters required in other algorithms. We present numerical evidences that such parametrization should allow an efficient in-situ calibration of the pulse. Next, we consider the flux-tunable coupler by IBM. We show optimization can be carried out in a more realistic model of the system than was employed in the original study, which is expected to further simplify the calibration process. Moreover, GOAT reduced the complexity of the optimal pulse to only 6 Fourier components, composed with analytic wrappers.

  11. A HACCP-based approach to mastitis control in dairy herds. Part 2: Implementation and evaluation

    Science.gov (United States)

    2011-01-01

    Part 1 of the study described the development of a Hazard Analysis and Critical Control Point (HACCP) based programme and accompanying handbook for the control of mastitis. This paper describes the implementation and evaluation of customised HACCP-based programmes, which were developed from the handbook and assessed on six Irish dairy farms. Both quantitative and qualitative (action research) research methodologies were used to measure the success of implementation and efficacy of control of sub-clinical mastitis as measured by Somatic Cell Counts (SCC) and the degree of compliance by farmers in adopting and maintaining recommendations throughout the course of the study period. No overall differences in SCC before and during the implementation of the study were found when all six farms were considered together. Three of the six study farms experienced a significant decrease in herd milk recorded SCC during the implementation of the control programme. An essential part of the study was achieving initial agreement on recommendations as well as ongoing monitoring of compliance during the study. This pilot study shows that HACCP can be implemented on farms as a means of working towards the control of mastitis and that farmer attitude, and understanding of mastitis are crucial in terms of motivation irrespective of practical approaches used to manage mastitis. PMID:21777494

  12. Export Control Guide: Loose Parts Monitoring Systems for Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Langenberg, Donald W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2012-12-01

    This report describes a typical LPMS, emphasizing its application to the RCS of a modern NPP. The report also examines the versatility of AE monitoring technology by describing several nuclear applications other than loose parts monitoring, as well as some non-nuclear applications. In addition, LPMS implementation requirements are outlined, and LPMS suppliers are identified. Finally, U.S. export controls applicable to LPMSs are discussed.

  13. Efficacy of Lactic Acid, Lactic Acid-Acetic Acid Blends, and Peracetic Acid To Reduce Salmonella on Chicken Parts under Simulated Commercial Processing Conditions.

    Science.gov (United States)

    Ramirex-Hernandez, Alejandra; Brashears, Mindy M; Sanchez-Plata, Marcos X

    2018-01-01

    The poultry processing industry has been undergoing a series of changes as it modifies processing practices to comply with new performance standards for chicken parts and comminuted poultry products. The regulatory approach encourages the use of intervention strategies to prevent and control foodborne pathogens in poultry products and thus improve food safety and protect human health. The present studies were conducted to evaluate the efficacy of antimicrobial interventions for reducing Salmonella on inoculated chicken parts under simulated commercial processing conditions. Chicken pieces were inoculated by immersion in a five-strain Salmonella cocktail at 6 log CFU/mL and then treated with organic acids and oxidizing agents on a commercial rinsing conveyor belt. The efficacy of spraying with six different treatments (sterile water, lactic acid, acetic acid, buffered lactic acid, acetic acid in combination with lactic acid, and peracetic acid) at two concentrations was evaluated on skin-on and skin-off chicken thighs at three application temperatures. Skinless chicken breasts were used to evaluate the antimicrobial efficacy of lactic acid and peracetic acid. The color stability of treated and untreated chicken parts was assessed after the acid interventions. The lactic acid and buffered lactic acid treatments produced the greatest reductions in Salmonella counts. Significant differences between the control and water treatments were identified for 5.11% lactic acid and 5.85% buffered lactic acid in both skin-on and skin-off chicken thighs. No significant effect of treatment temperature for skin-on chicken thighs was found. Lactic acid and peracetic acid were effective agents for eluting Salmonella cells attached to chicken breasts.

  14. Tobacco control and gender in Southeast Asia. Part I: Malaysia and the Philippines.

    Science.gov (United States)

    Morrow, Martha; Barraclough, Simon

    2003-09-01

    In the World Health Organization's Western Pacific Region, being born male is the single greatest risk marker for tobacco use. While the literature demonstrates that risks associated with tobacco use may vary according to sex, gender refers to the socially determined roles and responsibilities of men and women, who initiate, continue and quit using tobacco for complex and often different reasons. Cigarette advertising frequently appeals to gender roles. Yet tobacco control policy tends to be gender-blind. Using a broad gender-sensitivity framework, this contradiction is explored in four Western Pacific countries. Part I of the study discusses issues surrounding gender and tobacco, and analyses developments in Malaysia and the Philippines. Part II deals with Singapore and Vietnam. In all four countries, gender was salient for the initiation and maintenance of smoking, and in Malaysia and the Philippines was highly significant in cigarette promotion. Yet, with a few exceptions, gender was largely unrecognized in control policy. Suggestions for overcoming this weakness in order to enhance tobacco control are made in Part II.

  15. A high control bandwidth design method for aalborg inverter under weak grid condition

    DEFF Research Database (Denmark)

    Wu, Weimin; Zhou, Cong; Wang, Houqin

    2017-01-01

    Aalborg Inverter is a kind of high efficient Buck-Boost inverter. Since it may work in “Buck-Boost” mode, the control bandwidth should be high enough to ensure a good performance under any grid condition. However, during the “Boost” operation, the control bandwidth depends much on the grid...

  16. Conditioned food aversion to control outbreaks of intoxication by Ipomoea carnea and Turbina cordata in goats

    Science.gov (United States)

    Conditioned food aversion is used to train livestock to avoid the ingestion of toxic plants. This technique was used to control Turbina cordata poisoning in goats in one farm, and to control Ipomoea carnea subsp. istulosa poisoning in another farm. The goats were penned at night and the next mornin...

  17. Haptic control of a pneumatic muscle actuator to provide resistance for simulated isokinetic exercise; part II: control development and testing.

    Science.gov (United States)

    Hall, Kara L; Phillips, Chandler A; Reynolds, David B; Mohler, Stanley R; Rogers, Dana B; Neidhard-Doll, Amy T

    2015-01-01

    Pneumatic muscle actuators (PMAs) have a high power to weight ratio and possess unique characteristics which make them ideal actuators for applications involving human interaction. PMAs are difficult to control due to nonlinear dynamics, presenting challenges in system implementation. Despite these challenges, PMAs have great potential as a source of resistance for strength training and rehabilitation. The objective of this work was to control a PMA for use in isokinetic exercise, potentially benefiting anyone in need of optimal strength training through a joint's range of motion. The controller, based on an inverse three-element phenomenological model and adaptive nonlinear control, allows the system to operate as a type of haptic device. A human quadriceps dynamic simulator was developed (as described in Part I of this work) so that control effectiveness and accommodation could be tested prior to human implementation. Tracking error results indicate that the control system is effective at producing PMA displacement and resistance necessary for a scaled, simulated neuromuscular actuator to maintain low-velocity isokinetic movement during simulated concentric and eccentric knee extension.

  18. Alignment Condition-Based Robust Adaptive Iterative Learning Control of Uncertain Robot System

    Directory of Open Access Journals (Sweden)

    Guofeng Tong

    2014-04-01

    Full Text Available This paper proposes an adaptive iterative learning control strategy integrated with saturation-based robust control for uncertain robot system in presence of modelling uncertainties, unknown parameter, and external disturbance under alignment condition. An important merit is that it achieves adaptive switching of gain matrix both in conventional PD-type feedforward control and robust adaptive control in the iteration domain simultaneously. The analysis of convergence of proposed control law is based on Lyapunov's direct method under alignment initial condition. Simulation results demonstrate the faster learning rate and better robust performance with proposed algorithm by comparing with other existing robust controllers. The actual experiment on three-DOF robot manipulator shows its better practical effectiveness.

  19. Scram characteristics of the control rods of a pressurized water reactor under seismic conditions

    International Nuclear Information System (INIS)

    Fujita, Katsuhisa; Shinohara, Yoshikazu; Nakatogawa, Tetsuto; Nanbu, Kiyoshi; Nomura, Tomonori.

    1987-01-01

    Control rod drop verification experiments of a pressurized water reactor under seismic conditions are performed to confirm the insertion function of control rods into a core. To evaluate these tests, computer simulations are performed. A fuel assembly, control rods, guide tube and other associated structures are immersed in a water tank, and shaken by four hydraulic shakers. The scram time of control rods under seismic conditions was measured, and confirmed to meet the scram function. Moreover, vibrational response characteristics of core structures and dropping behavior of control rods in consideration of collisions are calculated by using a finite difference method. The behavior of the dropping control rods and the scram time obtained by the computer simulation show a very good agreement with the verification experimental results. (author)

  20. Sector-condition-based results for adaptive control and synchronization of chaotic systems under input saturation

    International Nuclear Information System (INIS)

    Iqbal, Muhammad; Rehan, Muhammad; Hong, Keum-Shik; Khaliq, Abdul; Saeed-ur-Rehman

    2015-01-01

    This paper addresses the design of adaptive feedback controllers for two problems (namely, stabilization and synchronization) of chaotic systems with unknown parameters by considering input saturation constraints. A novel generalized sector condition is developed to deal with the saturation nonlinearities for synthesizing the nonlinear and the adaptive controllers for the stabilization and synchronization control objectives. By application of the proposed sector condition and rigorous regional stability analysis, control and adaptation laws are formulated to guarantee local stabilization of a nonlinear system under actuator saturation. Further, simple control and adaptation laws are developed to synchronize two chaotic systems under uncertain parameters and input saturation nonlinearity. Numerical simulation results for Rössler and FitzHugh–Nagumo models are provided to demonstrate the effectiveness of the proposed adaptive stabilization and synchronization control methodologies

  1. Production controls (PC) and technical verification testing (TVT). A methodology for the control and tracking of LILW waste package conditioning

    International Nuclear Information System (INIS)

    Leon, A.M.; Nieto, J.L.L.; Garrido, J.G.

    2003-01-01

    As part of its low and intermediate level radioactive waste (LILW) characterisation and acceptance activities, ENRESA has set up a quality control programme that covers the different phases of radioactive waste package production and implies different levels of tracking in generation, assessment of activity and control of the documentation associated therewith. Furthermore, ENRESA has made available the mechanisms required for verification, depending on the results of periodic sampling, of the quality of the end product delivered by the waste producers. Both processes are included within the framework of two programmes of complementary activities: production controls (PC) and technical verification testing (TVT). (orig.)

  2. Assessment of the operating conditions of coordinated Q-V controller within secondary voltage control system

    Directory of Open Access Journals (Sweden)

    Arnautović Dušan

    2014-01-01

    Full Text Available The paper, discusses the possibility to use coordinated Q-V controller (CQVC to perform secondary voltage control at the power plant level. The CQVC performs the coordination of the synchronous generators' (SG reactive power outputs in order to maintain the same total reactive power delivered by the steam power plant (SPP, while at the same time maintaining a constant voltage with programmed reactive droop characteristic at the SPP HV busbar. This busbar is the natural pilot node for secondary voltage control at HV level as the node with maximum power production and maximum power consumption. In addition to voltage control, the CQVC maintains the uniform allocation of reactive power reserves at all SGs in the power plant. This is accomplished by setting the reactive power of each SG at given operating point in accordance to the available reactive power of the same SG at that point. Different limitations imposed by unit's and plant equipment are superimposed on original SG operating chart (provided by the manufacturer in order to establish realistic limits of SG operation at given operating point. The CQVC facilitates: i practical implementation of secondary voltage control in power system, as it is capable of ensuring delivery of reactive power as requested by regional/voltage control while maintaining voltage at system pilot node, ii the full deployment of available reactive power of SGs which in turn contributes to system stability, iii assessment of the reactive power impact/contribution of each generator in providing voltage control as ancillary service. Furthermore, it is also possible to use CQVC to pricing reactive power production cost at each SG involved and to design reactive power bidding structure for transmission network devices by using recorded data. Practical exploitation experience acquired during CQVC continuous operation for over two years enabled implementation of the optimal setting of reference voltage and droop on daily

  3. Approximate controllability of a semilinear elliptic problem with Robin condition in a periodically perforated domain

    Directory of Open Access Journals (Sweden)

    Nikita Agarwal

    2017-07-01

    Full Text Available In this article, we study the approximate controllability and homegenization results of a semi-linear elliptic problem with Robin boundary condition in a periodically perforated domain. We prove the existence of minimal norm control using Lions constructive approach, which is based on Fenchel-Rockafeller duality theory, and by means of Zuazua's fixed point arguments. Then, as the homogenization parameter goes to zero, we link the limit of the optimal controls (the limit of fixed point of the controllability problems with the optimal control of the corresponding homogenized problem.

  4. Frequency-Domain Robust Performance Condition for Controller Uncertainty in SISO LTI Systems: A Geometric Approach

    Directory of Open Access Journals (Sweden)

    Vahid Raissi Dehkordi

    2009-01-01

    Full Text Available This paper deals with the robust performance problem of a linear time-invariant control system in the presence of robust controller uncertainty. Assuming that plant uncertainty is modeled as an additive perturbation, a geometrical approach is followed in order to find a necessary and sufficient condition for robust performance in the form of a bound on the magnitude of controller uncertainty. This frequency domain bound is derived by converting the problem into an optimization problem, whose solution is shown to be more time-efficient than a conventional structured singular value calculation. The bound on controller uncertainty can be used in controller order reduction and implementation problems.

  5. Optimal control of building storage systems using both ice storage and thermal mass – Part I: Simulation environment

    International Nuclear Information System (INIS)

    Hajiah, Ali; Krarti, Moncef

    2012-01-01

    Highlights: ► A simulation environment is described to account for both passive and active thermal energy storage (TES) systems. ► Laboratory testing results have been used to validate the predictions from the simulation environment. ► Optimal control strategies for TES systems have been developed as part of the simulation environment. - Abstract: This paper presents a simulation environment that can evaluate the benefits of using simultaneously building thermal capacitance and ice storage system to reduce total operating costs including energy and demand charges while maintaining adequate occupant comfort conditions within commercial buildings. The building thermal storage is controlled through pre-cooling strategies by setting space indoor air temperatures. The ice storage system is controlled by charging the ice tank and operating the chiller during low electrical charge periods and melting the ice during on-peak periods. Optimal controls for both building thermal storage and ice storage are developed to minimize energy charges, demand charges, or combined energy and demand charges. The results obtained from the simulation environment are validated using laboratory testing for an optimal controller.

  6. Theoretical Background for the Decision-Making Process Modelling under Controlled Intervention Conditions

    OpenAIRE

    Bakanauskienė Irena; Baronienė Laura

    2017-01-01

    This article is intended to theoretically justify the decision-making process model for the cases, when active participation of investing entities in controlling the activities of an organisation and their results is noticeable. Based on scientific literature analysis, a concept of controlled conditions is formulated, and using a rational approach to the decision-making process, a model of the 11-steps decision-making process under controlled intervention is presented. Also, there have been u...

  7. Potential electricity savings by variable speed control of compressor for air conditioning systems

    Energy Technology Data Exchange (ETDEWEB)

    Nasution, Henry [Bung Hatta University, Department of Mechanical Engineering, Faculty of Industrial Engineering, Padang, West Sumatera (Indonesia); Wan Hassan, Mat Nawi [Universiti Teknologi Malaysia, Faculty of Mechanical Engineering, Skudai, Johor Bahru-Darul Ta' zim (Malaysia)

    2006-05-15

    The potential of a variable-speed compressor running on a controller to provide enhanced load-matching capability, energy saving and thermal comfort for application in air-conditioning system is demonstrated. An air-conditioning system, originally operated on a constant speed mode, is retrofitted with an inverter and a PID controller. The system was installed to a thermal environmental room together with a data acquisition system to monitor energy consumption and temperature of the room. Measurements were taken 2 h daily at a time interval of 5 min for an on/off and an inverter variable-speed conditions. The results indicate that thermal comfort of the room together with energy saving can be obtained through a proper selection of K for the controller. At a temperature setting of 22 C, the energy saving for the system is estimated to reach 25.3% for PID controllers. (orig.)

  8. Optimal control of distributed parameter system with incomplete information about the initial condition

    International Nuclear Information System (INIS)

    Kotarski, W.; Kowalewski, A.

    1982-03-01

    In this paper we consider an optimal control problem for a system described by a linear partial differential equation of the parabolic type with Dirichlet's boundary condition. We impose some constraints on the control. The performance functional has the integral form. The control time T is fixed. The initial condition is not given by a known function but belongs to a certain set (incomplete information about the initial state). The problem formulated in this paper describes the process of optimal heating, of which we do not have exact information about the initial temperature on the heated object. We present an example in which the set of admissible controls and one of initial conditions are given by means of the norm constraints too. The application of the well-known projective gradient method in the Hilbert space allows us to obtain the numerical solution for our optimization problem. (author)

  9. Tutorial on Feedback Control of Flows, Part I: Stabilization of Fluid Flows in Channels and Pipes

    Directory of Open Access Journals (Sweden)

    Ole M. Aamo

    2002-07-01

    Full Text Available The field of flow control has picked up pace over the past decade or so, on the promise of real-time distributed control on turbulent scales being realizable in the near future. This promise is due to the micromachining technology that emerged in the 1980s and developed at an amazing speed through the 1990s. In lab experiments, so called micro-electro-mechanical systems (MEMS that incorporate the entire detection-decision-actuation process on a single chip, have been batch processed in large numbers and assembled into flexible skins for gluing onto body-fluid interfaces for drag reduction purposes. Control of fluid flows span a wide variety of specialities. In Part I of this tutorial, we focus on the problem of reducing drag in channel and pipe flows by stabilizing the parabolic equilibrium profile using boundary feedback control. The control strategics used for this problem include classical control, based on the Nyquist criteria, and various optimal control techniques (H2, H-Infinity, as well as applications of Lyapunov stability theory.

  10. Muscodor albus Volatiles Control Toxigenic Fungi under Controlled Atmosphere (CA Storage Conditions

    Directory of Open Access Journals (Sweden)

    Gordon Braun

    2012-11-01

    Full Text Available Muscodor albus, a biofumigant fungus, has the potential to control post-harvest pathogens in storage. It has been shown to produce over 20 volatile compounds with fungicidal, bactericidal and insecticidal properties. However, M. albus is a warm climate endophyte, and its biofumigant activity is significantly inhibited at temperatures below 5 °C. Conidia of seven mycotoxin producing fungi, Aspergillus carbonarius, A. flavus, A. niger, A. ochraceus, Penicillium verrucosum, Fusarium culmorum and F. graminearum, were killed or prevented from germinating by exposure to volatiles from 2 g M. albus-colonized rye grain per L of headspace in sealed glass jars for 24 h at 20 °C. Two major volatiles of M. albus, isobutyric acid (IBA and 2-methyl-1-butanol (2MB at 50 µL/L and 100 µL/L, respectively, gave differential control of the seven fungi when applied individually at 20 °C. When the fungi were exposed to both IBA and 2MB together, an average of 94% of the conidia were killed or suppressed. In a factorial experiment with controlled atmosphere storage (CA at 3 °C and 72 h exposure to four concentrations of IBA and 2MB combinations, 50 µL/L IBA plus 100 µL/L 2MB killed or suppressed germination of the conidia of all seven fungi. Controlled atmosphere had no significant effect on conidial viability or volatile efficacy. Major volatiles of M. albus may have significant potential to control plant pathogens in either ambient air or CA storage at temperatures below 5 °C. However, combinations of volatiles may be required to provide a broader spectrum of control than individual volatiles.

  11. Demand Controlled Economizer Cycles: A Direct Digital Control Scheme for Heating, Ventilating, and Air Conditioning Systems,

    Science.gov (United States)

    1984-05-01

    Control Ignored any error of 1/10th degree or less. This was done by setting the error term E and the integral sum PREINT to zero If then absolute value of...signs of two errors jeq tdiff if equal, jump clr @preint else zero integal sum tdiff mov @diff,rl fetch absolute value of OAT-RAT ci rl,25 is...includes a heating coil and thermostatic control to maintain the air in this path at an elevated temperature, typically around 80 degrees Farenheit (80 F

  12. Bidirectional Long Short-Term Memory Network with a Conditional Random Field Layer for Uyghur Part-Of-Speech Tagging

    Directory of Open Access Journals (Sweden)

    Maihemuti Maimaiti

    2017-11-01

    Full Text Available Uyghur is an agglutinative and a morphologically rich language; natural language processing tasks in Uyghur can be a challenge. Word morphology is important in Uyghur part-of-speech (POS tagging. However, POS tagging performance suffers from error propagation of morphological analyzers. To address this problem, we propose a few models for POS tagging: conditional random fields (CRF, long short-term memory (LSTM, bidirectional LSTM networks (BI-LSTM, LSTM networks with a CRF layer, and BI-LSTM networks with a CRF layer. These models do not depend on stemming and word disambiguation for Uyghur and combine hand-crafted features with neural network models. State-of-the-art performance on Uyghur POS tagging is achieved on test data sets using the proposed approach: 98.41% accuracy on 15 labels and 95.74% accuracy on 64 labels, which are 2.71% and 4% improvements, respectively, over the CRF model results. Using engineered features, our model achieves further improvements of 0.2% (15 labels and 0.48% (64 labels. The results indicate that the proposed method could be an effective approach for POS tagging in other morphologically rich languages.

  13. Analysis of uranium metallogenic conditions and prospective prognosis on the south-central part of the Xikang-Yunnan Axis

    International Nuclear Information System (INIS)

    Guo Baochi; Qian Farong; Cai Yuqi; Zhang Daishi

    1996-08-01

    Three types of uranium mineralizations (i.e., sandstone type, sodium metasomatite type and Proterozoic epimetamorphic rock type) are distinguished in the south-central part of the Xikang-Yunnan Axis, and their major characteristics are expounded. It is proposed that the Early Proterozoic crust has three elevation stages: primitive old land formation stage, subsidence stage and base mental reconsolidation stage, and that the Middle Proterozoic Kunyang Group is different from typical carbonate-siliceous-politic sedimentary formation which contains many regional uranium-rich horizons. The primitive uranium contents of some rocks in the region have been studied for the first time, and proposed a new knowledge that some relative rocks be recognized as the uranium source rocks of the region. It is pointed out that there are two kinds of hydrothermal alterations, namely, alkaline alteration and acidic alteration, and some areas with development of alkaline alteration have promising uranium-metallogenic potential. As for the U-metallogenic prospect of the region, three conclusions are summarized: (1) This region does not have favourable geologic conditions for the Australian-Canadian type Proterozoic unconformity-related uranium deposit; (2) The Proterozoic unconformity different from that of Australian-Canadian type does not have permission U-metallogenic potential either; (3) The alkaline (sodium) metasomatite type uranium mineralization in the region has some prospecting potential. Therefore on the basis of above-mentioned conclusions five relatively promising uranium-metallogenic prospects are selected. (4 refs.)

  14. 41 CFR 301-13.2 - Under what conditions will my agency pay for my additional travel expense(s) under this part?

    Science.gov (United States)

    2010-07-01

    ... will my agency pay for my additional travel expense(s) under this part? 301-13.2 Section 301-13.2 Public Contracts and Property Management Federal Travel Regulation System TEMPORARY DUTY (TDY) TRAVEL... conditions will my agency pay for my additional travel expense(s) under this part? When an additional travel...

  15. A Multiple Case Study Discovering Part-Time Faculties' Perceptions of Their Professional Needs, Working Conditions, Social Network, and Job Satisfaction at Three Community Colleges

    Science.gov (United States)

    Millner-Harlee, Tanya

    2010-01-01

    This study employed a multiple case study design to evaluate the perspectives of part-time faculties at three community colleges in the Northeast. The purpose of this study was to discover how needs, working conditions, and social networks influence the part-time faculties' job satisfaction. Maslow (1954), Bourdieu (1986), and Herzberg, Mausner,…

  16. Microcontroller Based Proportional Derivative Plus Conditional Integral Controller for Electro-Mechanical Dual Acting Pulley Continuously Variable Transmission Ratio Control

    International Nuclear Information System (INIS)

    Budianto, A; Tawi, K B; Hussein, M; Supriyo, B; Kob, M S Che; Zulkifli, Mohd Ezlamy; Khairuldean A K; Daraoh, Aishah; Ariyono, S

    2012-01-01

    Electro-Mechanical Dual Acting Pulley (EMDAP) Continuously Variable Transmission (CVT) is a transmission utilized by electro-mechanical actuated system. It has a potential to reduce energy consumption because it only needs power during changing CVT ratio and no power is needed to maintain CVT ratio due to self lock mechanism design. This paper proposed simple proportional derivative plus conditional integral (PDCI) controller to control EMDAP CVT ratio which can be simply implemented on a microcontroller. This proposed controller used Astrom-Hagglund method and Ziegler-Nichols formula to tune PDCI gain. The Proportional Derivative controller is directly activated from the start but Integral controller is only activated when the error value reaches error value setting point. Simulation using Matlab/Simulink software was conducted to evaluate PDCI system performance. The simulation results showed PDCI controller has ability to perform maximum overshoot 0.1%, 0.001 steady state error and 0.5s settling time. For clamping condition, settling time is about 11.46s during changing ratio from 2.0 to 0.7, while for release condition, settling time is about 8.33s during changing ratio from 0.7 to 2.0.

  17. PRINCIPLES OF STATE FINANCIAL CONTROL OF UKRAINE IN THE CONDITIONS OF EUROPEAN INTEGRATION

    Directory of Open Access Journals (Sweden)

    Yuliya Pustovit

    2018-01-01

    Full Text Available The purpose of the study is an improvement of principles of state financial control of Ukraine taking into account European advanced experience. The subject of the research is a comparative analysis of financial control principles and principles of state financial control of Ukraine with the international principles of financial control, envisaged at the international level, and the establishment of the expediency of their implementation in the national legislation in connection with the terms of European integration. The methodological background of the research is the combination of theoretical and scientific methods: analysis, synthesis and comparison, theoretical and logical generalization. The theoretical approaches are analysed according to the determination of conceptcategory of terms: “principle of financial control,” “principle of state financial control.” Existed principles of financial control, principles of state financial control of Ukraine, leading principles of financial control, what determined in Lima Declarations of Guidance on Auditing Precepts, general principles of supreme bodies of financial control activity that are envisaged in Declaration about general principles of supreme bodies of financial control activity of states-participants of CIS are investigated. Carrying out the analysis of financial control principles, principles of state financial control of Ukraine, and international principles of financial control, we reached a conclusion that basic principles (principles of legality, independence, objectivity, impartiality, publicity, neutrality are already normatively envisaged. There is the part of international principles (principle of competence, publicity, efficiency, well-proven, observance of professional ethics, violation prevention, obligatory of responsibility offensive for the accomplished violations of financial discipline that doesn’t have the normative consolidation in laws and regulations of

  18. Operating wind turbines in strong wind conditions by using feedforward-feedback control

    International Nuclear Information System (INIS)

    Feng, Ju; Sheng, Wen Zhong

    2014-01-01

    Due to the increasing penetration of wind energy into power systems, it becomes critical to reduce the impact of wind energy on the stability and reliability of the overall power system. In precedent works, Shen and his co-workers developed a re-designed operation schema to run wind turbines in strong wind conditions based on optimization method and standard PI feedback control, which can prevent the typical shutdowns of wind turbines when reaching the cut-out wind speed. In this paper, a new control strategy combing the standard PI feedback control with feedforward controls using the optimization results is investigated for the operation of variable-speed pitch-regulated wind turbines in strong wind conditions. It is shown that the developed control strategy is capable of smoothening the power output of wind turbine and avoiding its sudden showdown at high wind speeds without worsening the loads on rotor and blades

  19. A new method for controlling refrigerant flow in automobile air conditioning

    Energy Technology Data Exchange (ETDEWEB)

    Xuquan Li; Jiangping Chen; Zhijiu Chen [Shanghai Jiao Tong University (China). Institute of Refrigeration and Cryogenics Engineering; Weihua Liu; Wei Hu; Xiaobing Liu [Shanghai Delphi Automotive Air Conditiong Systems Co. Ltd., Changhai (China)

    2004-05-01

    This paper describes the improvement of the refrigerant flow control method by using an electronic expansion valve (EEV) which is driven by a stepper motor in automobile air conditioning system. An EEV can make a quick response to the abrupt change in the refrigerant flow rate during the change in automobile speed and the thermostatic on/off operation. The flow rate characteristic of the EEV for automobile air conditioning was presented. A microcontroller is used to receive the input signal and generate the output signal to control the opening of the EEV. The fuzzy self-tuning proportional-integral-derivative (PID) control method is employed. Experimental results show that the new control method can feed adequate refrigerant flow into the evaporator in various operations. The evaporator discharge air temperature has dropped by approximately 3{sup o}C as compared with that of the conventional PID control system. (author)

  20. A HACCP-based approach to mastitis control in dairy herds. Part 1: Development

    Directory of Open Access Journals (Sweden)

    Beekhuis-Gibbon Lies

    2011-03-01

    Full Text Available Abstract Hazard Analysis and Critical Control Points (HACCP systems are a risk based preventive approach developed to increase levels of food safety assurance. This is part 1 of a pilot study on the development, implementation and evaluation of a HACCP-based approach for the control of good udder health in dairy cows. The paper describes the use of a novel approach based on a deconstruction of the infectious process in mastitis to identify Critical Control Points (CCPs and develop a HACCP-based system to prevent and control mastitis in dairy herds. The approach involved the creation of an Infectious Process Flow Diagram, which was then cross-referenced to two production process flow diagrams of the milking process and cow management cycle. The HACCP plan developed, may be suitable for customisation and implementation on dairy farms. This is a logical, systematic approach to the development of a mastitis control programme that could be used as a template for the development of control programmes for other infectious diseases in the dairy herd.

  1. A HACCP-based approach to mastitis control in dairy herds. Part 1: Development.

    Science.gov (United States)

    Beekhuis-Gibbon, Lies; Whyte, Paul; O'Grady, Luke; More, Simon J; Doherty, Michael L

    2011-03-31

    Hazard Analysis and Critical Control Points (HACCP) systems are a risk based preventive approach developed to increase levels of food safety assurance. This is part 1 of a pilot study on the development, implementation and evaluation of a HACCP-based approach for the control of good udder health in dairy cows. The paper describes the use of a novel approach based on a deconstruction of the infectious process in mastitis to identify Critical Control Points (CCPs) and develop a HACCP-based system to prevent and control mastitis in dairy herds. The approach involved the creation of an Infectious Process Flow Diagram, which was then cross-referenced to two production process flow diagrams of the milking process and cow management cycle. The HACCP plan developed, may be suitable for customisation and implementation on dairy farms. This is a logical, systematic approach to the development of a mastitis control programme that could be used as a template for the development of control programmes for other infectious diseases in the dairy herd.

  2. Simulations and Experiments on Vibration Control of Aerospace Thin-Walled Parts via Preload

    Directory of Open Access Journals (Sweden)

    Qiong Wu

    2017-01-01

    Full Text Available Thin-walled parts primarily comprise the entire piece of rough machining, and the material removal rate can surpass 95%. Numerous components with thin-walled structures are preferred in the aerospace industry for their light weight, high strength, and other advantages. In aerospace thin-walled workpiece machining processes and practical applications, they are excited by the vibration. The preload changing the modal stiffness of the part is found and this change causes continuous changes in the natural frequency. Researching on the influence of pretightening force on dynamic characteristics of thin-walled components is highly significant for controlling vibration. In this study, the typical aviation thin-walled part is the research object. Finite element numerical simulation and experimental verification are employed to analyze the dynamic characteristics of 7075 aluminum alloy thin-walled plates under different preloads for exploring the relationship between natural frequency and preload. The relationship is validated by comparative results. Both the simulation and experimental results show that the natural frequencies of plates increase following the augmentation of the preload. Thus, this research introduces the method where vibration of aerospace thin-walled parts is reduced by preload. For practical engineering application, a program showing the relationship between natural frequency and preload is written using Visual Basic language.

  3. The ash in forest fire affected soils control the soil losses. Part 1. The pioneer research

    Science.gov (United States)

    Cerdà, Artemi; Pereira, Paulo

    2013-04-01

    composition (Pereira and Úbeda, 2010) and Pereira et al., 2012). Some of the new research challenges related to ash impact in the fire affected soils are related to the ash redistribution after the fire, the impact of ash in soil and water chemistry, the temporal changes of soil erosion, the control ash exert on vegetation recovery and the role to be played by ash in the best management of fire affected land. Those topics needs new ideas and new scientists such as Paulo Pereira show in the Part II of this abstract. Acknowledgements, Lithuanian Research Council. Project LITFIRE, Fire effects on Lithuanian soils and ecosystems (MIP-48/2011) and the research projects GL2008-02879/BTE and LEDDRA 243857. References Bodí, M., Mataix-Solera, J., Doerr, S., and Cerdà, A. 2011b. The wettability of ash from burned vegetation and its relationship to Mediterranean plant species type, burn severity and total organic carbon content. Geoderma, 160, 599-607. Cerdà, A. 1998a. Postfire dynamics of erosional processes under mediterranean climatic conditions. Z. Geomorphol., 42 (3) 373-398. Cerdà, A. 1998b. Changes in overland flow and infiltration after a rangeland fire in a Mediterranean scrubland. Hydrological Processes, 12, 1031-1042. Cerdà, A., and Doerr, S. H.2010. The effect of ant mounds on overland flow and soil erodibility following a wildfire in eastern Spain. Ecohydrology, 3, 392-401. Cerdà, A., and Doerr, S.H. 2008. The effect of ash and needle cover on surface runoff and erosion in the immediate post-fire period. Catena, 74, 256-263. Pereira, P., and Úbeda, X. 2010. Spatial distribution of heavy metals released from ashes after a wildfire, Journal of Environment Engineering and Landscape Management, 18, 13-22. Pereira, P., Ubeda, X., Martin, D.A. 2012. Fire severity effects on ash chemical composition and extractable elements. Geoderma, 191, 105 - 114. Pérez-Cabello, F., Cerdà, A., de la Riva, J., Echeverría, M.T., García-Martín, A., Ibarra, P., Lasanta, T., Montorio

  4. Monitoring single-cell gene regulation under dynamically controllable conditions with integrated microfluidics and software

    NARCIS (Netherlands)

    Kaiser, Matthias; Jug, Florian; Julou, Thomas; Deshpande, S.R.; Pfohl, Thomas; Silander, Olin K.; Myers, Gene; Van Nimwegen, Erik

    2018-01-01

    Much is still not understood about how gene regulatory interactions control cell fate decisions in single cells, in part due to the difficulty of directly observing gene regulatory processes in vivo. We introduce here a novel integrated setup consisting of a microfluidic chip and accompanying

  5. 78 FR 63848 - Special Conditions: Embraer S.A., Model EMB-550 Airplanes; Sidestick Controllers

    Science.gov (United States)

    2013-10-25

    ... interested people to take part in this rulemaking by sending written comments, data, or views. The most..., fractional, charter, and private owner operations. The aircraft has a conventional configuration with low..., freedom of arm movement, controller displacement, handgrip size and accommodations for a range of pilot...

  6. A Mathematical Formulation of the SCOLE Control Problem. Part 2: Optimal Compensator Design

    Science.gov (United States)

    Balakrishnan, A. V.

    1988-01-01

    The study initiated in Part 1 of this report is concluded and optimal feedback control (compensator) design for stability augmentation is considered, following the mathematical formulation developed in Part 1. Co-located (rate) sensors and (force and moment) actuators are assumed, and allowing for both sensor and actuator noise, stabilization is formulated as a stochastic regulator problem. Specializing the general theory developed by the author, a complete, closed form solution (believed to be new with this report) is obtained, taking advantage of the fact that the inherent structural damping is light. In particular, it is possible to solve in closed form the associated infinite-dimensional steady-state Riccati equations. The SCOLE model involves associated partial differential equations in a single space variable, but the compensator design theory developed is far more general since it is given in the abstract wave equation formulation. The results thus hold for any multibody system so long as the basic model is linear.

  7. Performance of diagonal control structures at different operating conditions for polymer electrolyte membrane fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Serra, Maria; Husar, Attila; Feroldi, Diego; Riera, Jordi [Institut de Robotica i Informatica Industrial, Universitat Politecnica de Catalunya, Consejo Superior de Investigaciones Cientificas, C. Llorens i Artigas 4, 08028 Barcelona (Spain)

    2006-08-25

    This work is focused on the selection of operating conditions in polymer electrolyte membrane fuel cells. It analyses efficiency and controllability aspects, which change from one operating point to another. Specifically, several operating points that deliver the same amount of net power are compared, and the comparison is done at different net power levels. The study is based on a complex non-linear model, which has been linearised at the selected operating points. Different linear analysis tools are applied to the linear models and results show important controllability differences between operating points. The performance of diagonal control structures with PI controllers at different operating points is also studied. A method for the tuning of the controllers is proposed and applied. The behaviour of the controlled system is simulated with the non-linear model. Conclusions indicate a possible trade-off between controllability and optimisation of hydrogen consumption. (author)

  8. Single room control for user-optimised room air conditions; Einzelraumregelung fuer nutzungsoptimiertes Raumklima

    Energy Technology Data Exchange (ETDEWEB)

    Lezius, A. [Staefa Control System GmbH, Leinfelden-Echterdingen (Germany)

    1995-12-31

    In chapter 14 of the anthology about building control the single room control for achieving user-optimised room air conditions is described. The following aspects are discussed: What is comfort? What is economic efficiency? Systems for secondary air treatment, adapted functions of the measurement and control technique, management functions, orientation of the demand at the use, investment and amortisation. (BWI) [Deutsch] Kapitel 14 des Sammelbandes ueber Building control ist dem Thema der Einzelraumregelung zur Erzielung eines nutzungsoptimierten Raumklimas gewidmet. In diesem Zusammenhang werden folgende Themenbereiche angesprochen: Was ist Komfort? Was ist Wirtschaftlichkeit? Systeme fuer sekundaere Luftbehandlung; Angepasste Funktionen der MSR-Technik; Managementfunktionen; Bedarfsorientierung an der Nutzung; Investition und Amortisation. (BWI)

  9. Tobacco control and gender in south-east Asia. Part II: Singapore and Vietnam.

    Science.gov (United States)

    Morrow, Martha; Barraclough, Simon

    2003-12-01

    In the World Health Organization's Western Pacific Region, being born male is the single greatest risk marker for tobacco use. While the literature demonstrates that risks associated with tobacco use may vary according to sex, gender refers to the socially determined roles and responsibilities of men and women, who initiate, continue and quit using tobacco for complex and often different reasons. Cigarette advertising frequently appeals to gender roles. Yet tobacco control policy tends to be gender-blind. Using a broad, gender-sensitivity framework, this contradiction is explored in four Western Pacific countries. Part I of the study presented the rationale, methodology and design of the study, discussed issues surrounding gender and tobacco, and analysed developments in Malaysia and the Philippines (see the previous issue of this journal). Part II deals with Singapore and Vietnam. In all four countries gender was salient for the initiation and maintenance of smoking. Yet, with a few exceptions, gender was largely unrecognized in control policy. Suggestions for overcoming this weakness in order to enhance tobacco control are made.

  10. Matters of Cost: Part I. Jones Learns about Balance Sheets: Part II. A Look at Budgetary Control: Part III. The Supervisor's "Do-It-Yourself" Series 3.

    Science.gov (United States)

    Smith, J. E.; And Others

    This guide, which is intended for new supervisors and managers to use in an independent study setting, deals with costing, balance sheets, and budgetary control. The first section, "Matters of Cost" by J. E. and J. F. Smith, deals with the following topics: profits and productivity, principles of costing, cost control and cost reduction, fixed and…

  11. Unified Subharmonic Oscillation Conditions for Peak or Average Current Mode Control

    OpenAIRE

    Fang, Chung-Chieh

    2013-01-01

    This paper is an extension of the author's recent research in which only buck converters were analyzed. Similar analysis can be equally applied to other types of converters. In this paper, a unified model is proposed for buck, boost, and buck-boost converters under peak or average current mode control to predict the occurrence of subharmonic oscillation. Based on the unified model, the associated stability conditions are derived in closed forms. The same stability condition can be applied to ...

  12. Quantitative trait loci associated with longevity of lettuce seeds under conventional and controlled deterioration storage conditions.

    Science.gov (United States)

    Schwember, Andrés R; Bradford, Kent J

    2010-10-01

    Lettuce (Lactuca sativa L.) seeds have poor shelf life and exhibit thermoinhibition (fail to germinate) above ∼25°C. Seed priming (controlled hydration followed by drying) alleviates thermoinhibition by increasing the maximum germination temperature, but reduces lettuce seed longevity. Controlled deterioration (CD) or accelerated ageing storage conditions (i.e. elevated temperature and relative humidity) are used to study seed longevity and to predict potential seed lifetimes under conventional storage conditions. Seeds produced in 2002 and 2006 of a recombinant inbred line (RIL) population derived from a cross between L. sativa cv. Salinas×L. serriola accession UC96US23 were utilized to identify quantitative trait loci (QTLs) associated with seed longevity under CD and conventional storage conditions. Multiple longevity-associated QTLs were identified under both conventional and CD storage conditions for control (non-primed) and primed seeds. However, seed longevity was poorly correlated between the two storage conditions, suggesting that deterioration processes under CD conditions are not predictive of ageing in conventional storage conditions. Additionally, the same QTLs were not identified when RIL populations were grown in different years, indicating that lettuce seed longevity is strongly affected by production environment. Nonetheless, a major QTL on chromosome 4 [Seed longevity 4.1 (Slg4.1)] was responsible for almost 23% of the phenotypic variation in viability of the conventionally stored control seeds of the 2006 RIL population, with improved longevity conferred by the Salinas allele. QTL analyses may enable identification of mechanisms responsible for the sensitivity of primed seeds to CD conditions and breeding for improved seed longevity.

  13. 30 CFR 90.301 - Respirable dust control plan; approval by District Manager; copy to part 90 miner.

    Science.gov (United States)

    2010-07-01

    ... District Manager; copy to part 90 miner. 90.301 Section 90.301 Mineral Resources MINE SAFETY AND HEALTH... control plan; approval by District Manager; copy to part 90 miner. (a) The District Manager will approve... District Manager shall consider whether: (1) The respirable dust control measures would be likely to...

  14. Electronically controlled mechanical seal for aerospace applications--Part 2: Transient tests

    Science.gov (United States)

    Wolff, Paul J.; Salant, Richard F.

    1995-01-01

    An electronically controlled mechanical seal for use as the purge gas seal in a liquid oxygen turbopump has been fabricated and tested under transient operating conditions. The thickness of the lubricating film is controlled by adjusting the coning of the carbon face. This is accomplished by applying a voltage to a piezoelectric actuator to which the carbon face is bonded. The seal has been operated with a closed-loop control system that utilizes either the leakage rate or seal face temperature as the feedback. Both speed and pressure transients have been imposed on the seal. The transient tests have demonstrated that the seal is capable of maintaing low leakage rates while limiting face temperatures.

  15. Sediment distribution and hydrologic conditions of the Potomac aquifer in Virginia and parts of Maryland and North Carolina

    Science.gov (United States)

    McFarland, Randolph E.

    2013-01-01

    hydrologic function have not been well understood. Water-supply planning and development efforts have been hampered, and interpretations of regulatory criteria for allowable water-level declines have been ambiguous. An investigation undertaken during 2010–11 by the U.S. Geological Survey, in cooperation with the Virginia Department of Environmental Quality, provides a comprehensive regional description of the spatial distribution of Potomac aquifer sediments and their relation to hydrologic conditions. Altitudes and thicknesses of 2,725 vertical sediment intervals represent the spatial distribution of Potomac aquifer sediments in the Virginia Coastal Plain and adjacent parts of Maryland and North Carolina. Sediment intervals are designated as either dominantly coarse or fine grained and were determined by interpretation of geophysical logs and ancillary information from 456 boreholes. Sediment-interval and borehole summary statistical data indicate regional trends in sediment lithology and stratigraphic continuity, upon which three structurally based and hydrologically distinct sediment depositional subareas are designated. Broad patterns of sediment deposition over time are inferred from published sediment pollen-age data. Discrepancies in previously drawn hydrostratigraphic relations between southeastern Virginia and northeastern North Carolina are partly resolved based on borehole geophysical logs and a recently documented geologic map and corehole. A conceptual model theorizes the depositional history of the sediments and geologically accounts for their distribution. Documented pumping tests of the Potomac aquifer at 197 locations produced 336 values of transmissivity and 127 values of storativity. Based on effective aquifer thicknesses, 296 values of sediment hydraulic conductivity and 113 values of sediment specific storage are calculated. Vertical hydraulic gradients are calculated from 9,479 pairs of water levels measured between November 17, 1953, and October 4

  16. El reduccionismo científico y el control de las conciencias. Parte II

    OpenAIRE

    Leonardo Viniegra Velázquez

    2014-01-01

    En esta segunda parte se analizan los vínculos de subordinación del quehacer científico con lo que se designa como la lógica del poder y la dominación, a través de dar prioridad absoluta a los hechos sobre las ideas y favorecer el conocimiento capitalizable por la innovación tecnológica, la cual es decisiva en la rentabilidad y competitividad de las grandes empresas (los intereses de lucro que gobiernan el planeta), y base de los mecanismos de control político-social de las conciencias y de l...

  17. Start-up conditions and the performance of women - and men - controlled businesses in manufacturing industries

    Directory of Open Access Journals (Sweden)

    Otilia Driga

    2010-01-01

    Full Text Available Recent research into the economic performance of women-controlled firms suggests that their underperformance may not be the result of differences in the managerial ability of women as compared to men, and that it may in fact be a consequence of differing levels of start-up resources. Using accounting data, we examine the effects that selected start-up conditions have had on the observed economic performance of a sample of 4450 Spanish manufacturing firms. The results, which indicate significant differences in the initial conditions and show lower levels of assets and employee numbers in women-controlled firms, have implications for the economic performance of such firms.

  18. Fuzzy logic controller implementation for a solar air-conditioning system

    International Nuclear Information System (INIS)

    Lygouras, J.N.; Botsaris, P.N.; Vourvoulakis, J.; Kodogiannis, V.

    2007-01-01

    The implementation of a variable structure fuzzy logic controller for a solar powered air conditioning system and its advantages are investigated in this paper. Two DC motors are used to drive the generator pump and the feed pump of the solar air-conditioner. Two different control schemes for the DC motors rotational speed adjustment are implemented and tested: the first one is a pure fuzzy controller, its output being the control signal for the DC motor driver. A 7 x 7 fuzzy matrix assigns the controller output with respect to the error value and the derivative of the error. The second scheme is a two-level controller. The lower level is a conventional PID controller, and the higher level is a fuzzy controller acting over the parameters of the low level controller. Step response of the two control loops are presented as experimental results. The contribution of this design is that in the control system, the fuzzy logic is implemented through software in a common, inexpensive, 16-bit microcontroller, which does not have special abilities for fuzzy control

  19. Fuzzy logic controller implementation for a solar air-conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Lygouras, J.N.; Vourvoulakis, J. [Laboratory of Electronics, School of Electrical and Computer Engineering, Democritus University of Thrace, Vas. Sofias 12, 67100 Xanthi (Greece); Botsaris, P.N. [Laboratory of Materials, Processes and Mechanical Design, School of Production and Management Engineering, Democritus University of Thrace 67100 Xanthi (Greece); Kodogiannis, V. [Centre for Systems Analysis, School of Computer Science, University of Westminster, London, HA1 3TP (United Kingdom)

    2007-12-15

    The implementation of a variable structure fuzzy logic controller for a solar powered air conditioning system and its advantages are investigated in this paper. Two DC motors are used to drive the generator pump and the feed pump of the solar air-conditioner. Two different control schemes for the DC motors rotational speed adjustment are implemented and tested: the first one is a pure fuzzy controller, its output being the control signal for the DC motor driver. A 7 x 7 fuzzy matrix assigns the controller output with respect to the error value and the derivative of the error. The second scheme is a two-level controller. The lower level is a conventional PID controller, and the higher level is a fuzzy controller acting over the parameters of the low level controller. Step response of the two control loops are presented as experimental results. The contribution of this design is that in the control system, the fuzzy logic is implemented through software in a common, inexpensive, 16-bit microcontroller, which does not have special abilities for fuzzy control. (author)

  20. Microstructural engineering applied to the controlled cooling of steel wire rod: Part I. Experimental design and heat transfer

    Science.gov (United States)

    Campbell, P. C.; Hawbolt, E. B.; Brimacombe, J. K.

    1991-11-01

    The goal of this study was to develop a mathematical model which incorporates heat flow, phase transformation kinetics, and property-structure-composition relationships to predict the mechanical properties of steel rod being control cooled under industrial conditions. Thus, the principles of microstructural engineering have been brought to bear on this interdisciplinary problem by combining computer modeling with laboratory measurements of heat flow, austenite decomposition kinetics, microstructure and mechanical properties, and industrial trials to determine heat transfer and obtain rod samples under known conditions. Owing to the length and diversity of the study, it is reported in three parts,[8191]the first of which is concerned with the heat flow measurements. A relatively simple and reliable technique, involving a preheated steel rod instrumented with a thermocouple secured at its centerline, has been devised to determine the cooling rate in different regions of the moving bed of rod loops on an operating Stelmor line. The measured thermal response of the rod has been analyzed by two transient conduction models (lumped and distributed parameter, respectively) to yield overall heat-transfer coefficients for radiation and convection. The adequacy of the technique has been checked by cooling instrumented rods under well-defined, air crossflow conditions in the laboratory and comparing measured heat-transfer coefficients to values predicted from well-established equations. The industrial thermal measurements have permitted the characterization of a coefficient to account for radiative interaction among adjacent rod loops near the edge and at the center of the bed.

  1. Comparative Analysis of Maximum Power Point Tracking Controllers under Partial Shaded Conditions in a Photovoltaic System

    Directory of Open Access Journals (Sweden)

    R. Ramaprabha

    2015-06-01

    Full Text Available Mismatching effects due to partial shaded conditions are the major drawbacks existing in today’s photovoltaic (PV systems. These mismatch effects are greatly reduced in distributed PV system architecture where each panel is effectively decoupled from its neighboring panel. To obtain the optimal operation of the PV panels, maximum power point tracking (MPPT techniques are used. In partial shaded conditions, detecting the maximum operating point is difficult as the characteristic curves are complex with multiple peaks. In this paper, a neural network control technique is employed for MPPT. Detailed analyses were carried out on MPPT controllers in centralized and distributed architecture under partial shaded environments. The efficiency of the MPPT controllers and the effectiveness of the proposed control technique under partial shaded environments was examined using MATLAB software. The results were validated through experimentation.

  2. Energy saving: optimal use of air conditioning equipment by means of the solar control; Ahorro de energia: uso optimo de los acondicionadores de aire mediante el control solar

    Energy Technology Data Exchange (ETDEWEB)

    Mejia D, David; Morillon G, David; Rodriguez V, Luis [Universidad Nacional Autonoma de Mexico (Mexico)

    2001-09-01

    In this article the evaluation of the solar heat gains through the transparent parts of a building (houses of social interest) is presented; with the purpose of determining the heat gains through windows during summer time and under the following conditions: without solar protection, with the use of eaves, solar breakers and, finally, with the use of both elements. With the determined percentage of the diminution of heat gains, the considered potential of energy saving in air conditioning was obtained that would be available if the houses were constructed with solar control. [Spanish] En este articulo se presenta la evaluacion de las ganancias de calor solar a traves de las partes transparentes de un edificio (viviendas de interes social); con el objeto de determinar las ganancias de calor a traves de ventanas para la epoca de verano y bajo las siguientes condiciones: sin proteccion solar, con el empleo de aleros, con quiebrasoles y, finalmente, con el empleo de ambos elementos. Con el porcentaje determinado de la disminucion de ganancias de calor, se obtuvo el potencial estimado de ahorro de energia en aire acondicionado que se tendria si las viviendas se construyen con control solar.

  3. Trends in Energy Management Technology - Part 3: State of Practiceof Energy Management, Control, and Information Systems

    Energy Technology Data Exchange (ETDEWEB)

    Yee, Gaymond; Webster, Tom

    2004-02-01

    In this report, the third in a series, we provide an evaluation of several products that exemplify the current state of practice of Energy Management, Control, and Information Systems (EMCIS). The available features for these products are summarized and analyzed with regard to emerging trends in EMCIS and potential benefits to the federal sector. The first report [1] covered enabling technologies for emerging energy management systems. The second report [2] serves as a basic reference for building control system (BCS) networking fundamentals and includes an assessment of current approaches to open communications. Part 4 of this series will discuss applications software from a user's perspective. It is important for energy managers in the Federal sector to have a high level of knowledge and understanding of these complex energy management systems. This series of reports provides energy practitioners with some basic informational and educational tools to help make decisions relative to energy management systems design, specification, procurement, and energy savings potential.

  4. Human Factors and Data Fusion as Part of Control Systems Resilience

    Energy Technology Data Exchange (ETDEWEB)

    David I. Gertman

    2009-05-01

    Human performance and human decision making is counted upon as a crucial aspect of overall system resilience. Advanced control systems have the potential to provide operators and asset owners a wide range of data, deployed at different levels that can be used to support operator situation awareness. However, the sheer amount of data available can make it challenging for operators to assimilate information and respond appropriately. This paper reviews some of the challenges and issues associated with providing operators with actionable state awareness and argues for the over arching importance of integrating human factors as part of intelligent control systems design and implementation. It is argued that system resilience is improved by implementing human factors in operations and maintenance. This paper also introduces issues associated with resilience and data fusion and highlights areas in which human factors including field studies hold promise.

  5. The present condition of the radiation safety control education in training schools for radiological technologists

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Saito, Kyoko; Hirai, Shoko; Igarashi, Hiroshi; Negishi, Tooru; Hirano, Kunihiro; Kawaharada, Yasuhiro

    2010-01-01

    We made a detailed study on the course of study in radiation safety control prescribed on March 28, 2003. Questionnaires were sent to 39 training schools for radiological technology, to which 66.7% replied (26/39). Subjects on radiation safety control must include knowledge and technology in both radiation control and medical safety. The contents for instruction of radiation control were in accordance with those given in the traditional program; however, some discrepancies were found in the contents of medical safety. As medical safety, emphasized by the revised Medical Service Law, is regarded as very important by many hospitals, safety control education that include medical ethics should be required as part of the curriculum in the training schools for radiological technologists. (author)

  6. Conditions for the existence of control functions in nonseparable simultaneous equations models

    OpenAIRE

    Blundell, Richard; Matzkin, Rosa L.

    2010-01-01

    The control function approach (Heckman and Robb (1985)) in a system of linear simultaneous equations provides a convenient procedure to estimate one of the functions in the system using reduced form residuals from the other functions as additional regressors. The conditions on the structural system under which this procedure can be used in nonlinear and nonparametric simultaneous equations has thus far been unknown. In this note, we define a new property of functions called control function s...

  7. Psychosocial work conditions, unemployment and health locus of control: a population-based study.

    Science.gov (United States)

    Sadiq Mohammad Ali; Lindström, Martin

    2008-06-01

    To investigate the association between psychosocial work conditions, unemployment and lack of belief in the possibility of influencing one's own health. The 2000 public health survey in Scania is a cross-sectional postal questionnaire study with a 59% participation rate. In total, 5180 persons aged 18-64 years who belonged to the workforce and the unemployed were included in this study. Logistic regression models were used to investigate the associations between psychosocial factors at work and unemployment, and lack of belief in the possibility of influencing one's own health (external locus of control). Psychosocial conditions at work were defined according to the Karasek-Theorell demand-control/decision latitudes into relaxed, active, passive, and job strain categories. The multivariate analyses included age, country of birth, education, economic stress, and social participation. In total, 26.6% of all men and 26.9% of all women lack an internal locus of control. The passive, job strain and unemployed categories have significantly higher odds ratios of lack of internal locus of control, as compared to the relaxed reference category. No such significant differences are observed for the active category. These patterns remain in the multivariate models, with the exception of the passive and unemployed categories among men, in which the significant differences disappear. Psychosocial work conditions and unemployment may affect health locus of control. The control dimension in the Karasek-Theorell model seems to be of greatest importance.

  8. 2-regularity and 2-normality conditions for systems with impulsive controls

    Directory of Open Access Journals (Sweden)

    Pavlova Natal'ya

    2007-01-01

    Full Text Available In this paper a controlled system with impulsive controls in the neighborhood of an abnormal point is investigated. The set of pairs (u,μ is considered as a class of admissible controls, where u is a measurable essentially bounded function and μ is a finite-dimensional Borel measure, such that for any Borel set B, μ(B is a subset of the given convex closed pointed cone. In this article the concepts of 2-regularity and 2-normality for the abstract mapping Ф, operating from the given Banach space into a finite-dimensional space, are introduced. The concepts of 2-regularity and 2-normality play a great role in the course of derivation of the first and the second order necessary conditions for the optimal control problem, consisting of the minimization of a certain functional on the set of the admissible processes. These concepts are also important for obtaining the sufficient conditions for the local controllability of the nonlinear systems. The convenient criterion for 2-regularity along the prescribed direction and necessary conditions for 2-normality of systems, linear in control, are introduced in this article as well.

  9. Regional differences in infection control conditions in a sample of primary health care services in Brazil

    Directory of Open Access Journals (Sweden)

    Mauro Henrique Nogueira Guimarães de Abreu

    2017-11-01

    Full Text Available International guidelines have pointed out the importance of the physical environment of health care facilities in preventing and controlling infection. We aimed to describe the physical environment of dental care facilities in Brazil in 2014, focusing on characteristics designed to control infections. Exactly 16,202 dental offices in the Brazilian Unified National Health System (SUS participated in this survey. Trained researchers extracted information about the infection control characteristics of health facilities by using a structured instrument. We used data from 12 dichotomous questions that evaluated the wall, floor, sink and tap conditions, and the presence and condition of sterilization equipment. We calculated a score by summing the number of characteristics handled appropriately for infection control, which could range from 0 to 12. Hierarchical cluster analyses were developed. None of the 12 criteria were met by all the oral health teams. Only 208 (1.3% dental offices correctly performed all 12-infection control practices. Two clusters, with different frequencies of structure for infection control in dental offices, were identified. South and Southeast regions had the highest frequencies for Cluster 1, with better structure of infection control in dental offices. Dental care facilities of oral health teams were not typically meeting the infection control guidelines regarding clinic design and equipment. Adherence to the guidelines varied among the Brazilian geographic regions.

  10. Fractional Programming for Communication Systems—Part I: Power Control and Beamforming

    Science.gov (United States)

    Shen, Kaiming; Yu, Wei

    2018-05-01

    This two-part paper explores the use of FP in the design and optimization of communication systems. Part I of this paper focuses on FP theory and on solving continuous problems. The main theoretical contribution is a novel quadratic transform technique for tackling the multiple-ratio concave-convex FP problem--in contrast to conventional FP techniques that mostly can only deal with the single-ratio or the max-min-ratio case. Multiple-ratio FP problems are important for the optimization of communication networks, because system-level design often involves multiple signal-to-interference-plus-noise ratio terms. This paper considers the applications of FP to solving continuous problems in communication system design, particularly for power control, beamforming, and energy efficiency maximization. These application cases illustrate that the proposed quadratic transform can greatly facilitate the optimization involving ratios by recasting the original nonconvex problem as a sequence of convex problems. This FP-based problem reformulation gives rise to an efficient iterative optimization algorithm with provable convergence to a stationary point. The paper further demonstrates close connections between the proposed FP approach and other well-known algorithms in the literature, such as the fixed-point iteration and the weighted minimum mean-square-error beamforming. The optimization of discrete problems is discussed in Part II of this paper.

  11. Variable structure TITO fuzzy-logic controller implementation for a solar air-conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Lygouras, J.N.; Pachidis, Th. [Laboratory of Electronics, School of Electrical and Computer Engineering, Democritus University of Thrace, GR-67100 Xanthi (Greece); Kodogiannis, V.S. [Centre for Systems Analysis, School of Computer Science, University of Westminster, London HA1 3TP (United Kingdom); Tarchanidis, K.N. [Department of Petroleum Technology, Technological Education Institute of Kavala, GR-65404, Kavala (Greece); Koukourlis, C.S. [Laboratory of Telecommunications, School of Electrical and Computer Engineering, Democritus University of Thrace, GR-67100 Xanthi (Greece)

    2008-04-15

    The design and implementation of a Two-Input/Two-Output (TITO) variable structure fuzzy-logic controller for a solar-powered air-conditioning system is described in this paper. Two DC motors are used to drive the generator pump and the feed pump of the solar air-conditioner. The first affects the temperature in the generator of the solar air-conditioner, while the second, the pressure in the power loop. The difficulty of Multi-Input/Multi-Output (MIMO) systems control is how to overcome the coupling effects among each degree of freedom. First, a traditional fuzzy-controller has been designed, its output being one of the components of the control signal for each DC motor driver. Secondly, according to the characteristics of the system's dynamics coupling, an appropriate coupling fuzzy-controller (CFC) is incorporated into a traditional fuzzy-controller (TFC) to compensate for the dynamic coupling among each degree of freedom. This control strategy simplifies the implementation problem of fuzzy control, but can also improve the control performance. This mixed fuzzy controller (MFC) can effectively improve the coupling effects of the systems, and this control strategy is easy to design and implement. Experimental results from the implemented system are presented. (author)

  12. An Innovative Adaptive Control System to Regulate Microclimatic Conditions in a Greenhouse

    Directory of Open Access Journals (Sweden)

    Giuseppina Nicolosi

    2017-05-01

    Full Text Available In the recent past home automation has been expanding its objectives towards new solutions both inside the smart home and in its outdoor spaces, where several new technologies are available. This work has developed an approach to integrate intelligent microclimatic greenhouse control into integrated home automation. Microclimatic control of greenhouses is a critical issue in agricultural practices, due to often common sudden daily variation of climatic conditions, and to its potentially detrimental effect on plant growth. A greenhouse is a complex thermodynamic system where indoor temperature and relative humidity have to be closely monitored to facilitate plant growth and production. This work shows an adaptive control system tailored to regulate microclimatic conditions in a greenhouse, by using an innovative combination of soft computing applications. In particular, a neural network solution has been proposed in order to forecast the climatic behavior of greenhouse, while a parallel fuzzy scheme approach is carried out in order to adjust the air speed of fan-coil and its temperature. The proposed combined approach provides a better control of greenhouse climatic conditions due to the system’s capability to base instantaneous solutions both on real measured variables and on forecasted climatic change. Several simulation campaigns were carried out to perform accurate neural network and fuzzy schemes, aimed at obtaining respectively a minimum forecasted error value and a more appropriate fuzzification and de-fuzzification process. A Matlab/Simulink solution implemented with a combined approach and its relevant obtained performance is also shown in present study, demonstrating that through controlled parameters it will be possible to maintain a better level of indoor climatic conditions. In the present work we prove how with a forecast of outside temperature at the next time-instant and rule-based controller monitoring of cooling or heating air

  13. Evaluation of the development and yielding potential of Chenopodium quinoa Willd. under the climatic conditions of Europe. Part one: accomodation of Chenopodium quinoa (Willd. to different conditions

    Directory of Open Access Journals (Sweden)

    Krzysztof Gęsiński

    2012-12-01

    Full Text Available Based on the evaluation of selected varieties of Chenopodium quinoa, their requirements were identified; it was shown which varieties demonstrated the best effects in what conditions. It was found that the best varieties for Europe's conditions were E-DK-4-PQCIP and RU-5-PQCIP. E-DK-4-PQCIP variety showed the best effects under the conditions of cluster II which included e.g. Bydgoszcz (Poland and cluster IV which included Southern European countries (Greece and Italy, while the best effects found in RU-5-PQCIP variety were identified in cluster I which included Sweden. E-DK-4-PQCIP variety in cluster II showed a very high yield of green matter and a mean seed yield, and in cluster IV - a very high seed yield and a high yield of green matter.

  14. Evaluation of the development and yielding potential of Chenopodium quinoa Willd. under the climatic conditions of Europe. Part Two: Yielding potential of Chenopodium quinoa under different conditions

    Directory of Open Access Journals (Sweden)

    Krzysztof Gęsiński

    2012-12-01

    Full Text Available The evaluation of Chenopodium quinoa cultivation effects in Poland has been compared with European research results. It was found that the conditions in Europe are favorable to Chenopodium quinoa cultivation. Poland has the mean length of the vegetation period. The maximum value of this trait was found in Sweden. The conditions in Bydgoszcz (Poland are very favorable to the cultivation for green matter and favorable as far as the seed yield is concerned. The most favorable seed yield was recorded in Greece.

  15. 50 CFR 22.32 - Conditions and limitations on taking under depredation control order.

    Science.gov (United States)

    2010-10-01

    ... Golden Eagles § 22.32 Conditions and limitations on taking under depredation control order. (a) Whenever the taking of golden eagles without a permit is authorized for the seasonal protection of livestock, such birds may be taken by firearms, traps, or other suitable means except by poison or from aircraft...

  16. Sporulation of Bremia lactucae affected by temperature, relative humidity, and wind in controlled conditions

    NARCIS (Netherlands)

    Su, H.; Bruggen, van A.H.C.; Subbarao, K.V.; Scherm, H.

    2004-01-01

    The effects of temperature (5 to 25degreesC), relative humidity (81 to 100%), wind speed (0 to 1.0 in s(-1)), and their interactions on sporulation of Bremia lactucae on lettuce cotyledons were investigated in controlled conditions. Sporulation was affected significantly (P <0.0001) by

  17. Assessment of Augmented Electronic Fuel Controls for Modular Engine Diagnostics and Condition Monitoring

    Science.gov (United States)

    1978-12-01

    removal of the horoscope . Diagnostic Conoctor - E4 Th10 E4 23-pin connoctor on the electrical control unit Is provided for ground- checking electrical...confidenou in engine condition monitoring * 1min general. Thi9 has boon especially true in~ eases where fUse signal s have c~aused engine shutdowns. Where ECWI

  18. Model predictions and control of conditions in a CA-reefer container

    NARCIS (Netherlands)

    Sman, van der R.G.M.; Verdijck, G.J.C.

    2003-01-01

    In this paper a concept for energy saving for refrigerated container transport is presented. The concept is based on model-predictive control of the set points of the cooling unit. These models predict energy consumption of the cooling unit, climatic conditions inside the cargo space, and the change

  19. Anti-seismic air condition's cooling capability increase of the second control area

    International Nuclear Information System (INIS)

    Pan Qiang

    2008-01-01

    Secondary area (SCA) air-conditioning system is an important ventilation system in plant. It should achieve the indoor temperature controllable. To resolve the problem of cooling capacity insufficiency, on the basis of ventilation and refrigeration theory, the thesis analyzes the design modification plan. (author)

  20. Hydrogen-control systems for severe LWR accident conditions - a state-of-technology report

    International Nuclear Information System (INIS)

    Hilliard, R.K.; Postma, A.K.; Jeppson, D.W.

    1983-03-01

    This report reviews the current state of technology regarding hydrogen safety issues in light water reactor plants. Topics considered in this report relate to control systems and include combustion prevention, controlled combustion, minimization of combustion effects, combination of control concepts, and post-accident disposal. A companion report addresses hydrogen generation, distribution, and combustion. The objectives of the study were to identify the key safety issues related to hydrogen produced under severe accident conditions, to describe the state of technology for each issue, and to point out ongoing programs aimed at resolving the open issues

  1. Adaptive Neural Control of Nonaffine Nonlinear Systems without Differential Condition for Nonaffine Function

    Directory of Open Access Journals (Sweden)

    Chaojiao Sun

    2016-01-01

    Full Text Available An adaptive neural control scheme is proposed for nonaffine nonlinear system without using the implicit function theorem or mean value theorem. The differential conditions on nonaffine nonlinear functions are removed. The control-gain function is modeled with the nonaffine function probably being indifferentiable. Furthermore, only a semibounded condition for nonaffine nonlinear function is required in the proposed method, and the basic idea of invariant set theory is then constructively introduced to cope with the difficulty in the control design for nonaffine nonlinear systems. It is rigorously proved that all the closed-loop signals are bounded and the tracking error converges to a small residual set asymptotically. Finally, simulation examples are provided to demonstrate the effectiveness of the designed method.

  2. Feedback linearization based control of a variable air volume air conditioning system for cooling applications.

    Science.gov (United States)

    Thosar, Archana; Patra, Amit; Bhattacharyya, Souvik

    2008-07-01

    Design of a nonlinear control system for a Variable Air Volume Air Conditioning (VAVAC) plant through feedback linearization is presented in this article. VAVAC systems attempt to reduce building energy consumption while maintaining the primary role of air conditioning. The temperature of the space is maintained at a constant level by establishing a balance between the cooling load generated in the space and the air supply delivered to meet the load. The dynamic model of a VAVAC plant is derived and formulated as a MIMO bilinear system. Feedback linearization is applied for decoupling and linearization of the nonlinear model. Simulation results for a laboratory scale plant are presented to demonstrate the potential of keeping comfort and maintaining energy optimal performance by this methodology. Results obtained with a conventional PI controller and a feedback linearizing controller are compared and the superiority of the proposed approach is clearly established.

  3. A power conditioning system for thermoelectric generator based on interleaved Boost converter with MPPT control

    DEFF Research Database (Denmark)

    Ni, L.-X; Sun, K.; Zhang, L.

    2011-01-01

    The thermoelectric generation (TEG) system has its special charactristics of high stablility, low voltage and high current output, which is different from PV modules. The power conditioning system and control schemes used in PV applications cannot be directly applied to TEG applications. A power...... conditioning system for TEG based on interleaved Boost converter with maximum power point tracking (MPPT) control is investigated in this paper. Since an internal resistance exists inside TEG modules, an improved perturbation and observation (P&O) MPPT control scheme with power limit is proposed to extract...... maximum power from TEG by matching the load with internal resistance. Since the battery is usually employed as the load for TEG systems, the interleaved Boost converter operates in two different modes for battery charging: before the battery is fully charged, the system outputs the maximum power (MPPT...

  4. Power system security enhancement with unified power flow controller under multi-event contingency conditions

    Directory of Open Access Journals (Sweden)

    S. Ravindra

    2017-03-01

    Full Text Available Power system security analysis plays key role in enhancing the system security and to avoid the system collapse condition. In this paper, a novel severity function is formulated using transmission line loadings and bus voltage magnitude deviations. The proposed severity function and generation fuel cost objectives are analyzed under transmission line(s and/or generator(s contingency conditions. The system security under contingency conditions is analyzed using optimal power flow problem. An improved teaching learning based optimization (ITLBO algorithm has been presented. To enhance the system security under contingency conditions in the presence of unified power flow controller (UPFC, it is necessary to identify an optimal location to install this device. Voltage source based power injection model of UPFC, incorporation procedure and optimal location identification strategy based on line overload sensitivity indexes are proposed. The entire proposed methodology is tested on standard IEEE-30 bus test system with supporting numerical and graphical results.

  5. Initial data of seismic input and soil conditions of Kozloduy NPP site. Extension to Part 2 soil conditions, issued October '93

    International Nuclear Information System (INIS)

    Boyadjiev, Z.

    1995-01-01

    On the basis of the results of the carried out experimental (laboratory and in situ) investigations of the dynamic characteristics, the following conclusions for the Kozloduy NPP site are presented. (1) The established through experimental studies relationships for the shear module and the damping factor as strain dependent of representative samples of soils of the site profile, can be used for all similar soils in the profile in the different parts of the site, taking into account the possible differences by means of the initial shear module in the normalized relationship for the respective generalized soil type. (2) When solving the problems of the site response and the 'soil - structure analysis', the geotechnical seismic model of the 'free field' profile can be assumed for all parts of the NPP site. (3) The changes of the lithological profile in different parts of the site, in respect to type and thickness, as well as in view of the different way and depth of the NPP structures foundation, make it necessary the elaboration of a geotechnical seismic model of the profile below the foundation plates of the reactor buildings of the NPP units in each particular case. These models can be made out on the basis of the summarized data about the shear velocities of the soil types, the lithological data of the studied boreholes in these places and the data having natural bulk density from 30 - 40 m depth determined by the laboratory studies of samples of these soils, assuming with approximation that the geotechnical seismic model below this depth is the same as the one of the 'free field'. (4) Studies have been carried out through in situ and laboratory studies of all the fundamental structures on the NPP site and the results of them are sufficient as an addition to the present initial data for solving the problems of the site response and the 'soil-structure inter-action' analyses of each structure

  6. Crack growth behaviour of low-alloy steels for pressure boundary components under transient light water reactor operating conditions - CASTOC, Part I: BWR/NWC conditions

    International Nuclear Information System (INIS)

    Ritter, S.; Seifert, H.P.; Devrient, B.; Roth, A.; Ehrnsten, U.; Ernestova, M.; Zamboch, M.; Foehl, J.; Weissenberg, T.; Gomez-Briceno, D.; Lapena, J.

    2004-01-01

    One of the ageing phenomena of pressure boundary components of light water reactors (LWR) is environmentally-assisted cracking (EAC). The project CASTOC (5. Framework Programme of the EU) was launched September 2000 with six European partners and terminated August 2003. It was focused in particular on the EAC behaviour of low-alloy steels (LAS) and to some extent to weld metal, heat affected zone and the influence of an austenitic cladding. The main objective was directed to the clarification of EAC crack growth behaviour/mechanism of LAS in high-temperature water under steady-state power operation (constant load) and transient operating conditions (e.g., start-up/shut-down, transients in water chemistry and load). Autoclave tests were performed with Western and Russian type reactor pressure vessel steels under simulated boiling water reactor (BWR)/normal water chemistry (NWC) and pressurised water reactor (VVER) conditions. The investigations were performed with fracture mechanics specimens of different sizes and geometries. The applied loading comprised cyclic loads, static loads and load spectra where the static load was periodically interrupted by partial unloading. With regard to water chemistry, the oxygen content (VVER) and impurities of sulphate and chlorides (BWR) were varied beyond allowable limits for continuous operation. The current paper summarises the most important crack growth results obtained under simulated BWR/NWC conditions. The results are discussed in the context of the current crack growth rate curves in the corresponding nuclear codes. (authors)

  7. Crack growth behaviour of low-alloy steels for pressure boundary components under transient light water reactor operating conditions - CASTOC, Part I: BWR/NWC conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, S.; Seifert, H.P. [Paul Scherrer Institute, PSI, Villigen (Switzerland); Devrient, B.; Roth, A. [Framatome ANP GmbH, Erlangen (Germany); Ehrnsten, U. [VTT Industrial Systems, Espoo (Finland); Ernestova, M.; Zamboch, M. [Nuclear Research Institute, NRI, Rez (Czech Republic); Foehl, J.; Weissenberg, T. [Staatliche Materialpruefungsanstalt, MPA, Stuttgart (Germany); Gomez-Briceno, D.; Lapena, J. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Madrid (Spain)

    2004-07-01

    One of the ageing phenomena of pressure boundary components of light water reactors (LWR) is environmentally-assisted cracking (EAC). The project CASTOC (5. Framework Programme of the EU) was launched September 2000 with six European partners and terminated August 2003. It was focused in particular on the EAC behaviour of low-alloy steels (LAS) and to some extent to weld metal, heat affected zone and the influence of an austenitic cladding. The main objective was directed to the clarification of EAC crack growth behaviour/mechanism of LAS in high-temperature water under steady-state power operation (constant load) and transient operating conditions (e.g., start-up/shut-down, transients in water chemistry and load). Autoclave tests were performed with Western and Russian type reactor pressure vessel steels under simulated boiling water reactor (BWR)/normal water chemistry (NWC) and pressurised water reactor (VVER) conditions. The investigations were performed with fracture mechanics specimens of different sizes and geometries. The applied loading comprised cyclic loads, static loads and load spectra where the static load was periodically interrupted by partial unloading. With regard to water chemistry, the oxygen content (VVER) and impurities of sulphate and chlorides (BWR) were varied beyond allowable limits for continuous operation. The current paper summarises the most important crack growth results obtained under simulated BWR/NWC conditions. The results are discussed in the context of the current crack growth rate curves in the corresponding nuclear codes. (authors)

  8. Coal forming conditions for coal seams and coal measures of the Heshan Group Upper Permian Series in Guangxi Province (part 1)

    Energy Technology Data Exchange (ETDEWEB)

    Li, Y.

    1980-10-01

    Coal forming conditions for the coal measures of the Heshan Group are discussed based on the analysis of the historical background and paleogeographical environment of the Permian in Guangxi Province. The roof, floor, and partings of the seams are composed of algal micritic limestone, therefore affirming that the central part of Guangxi Province in the late Permian was a typical epi-continental sea. The compensative deposit of algea on the carbonate platform in very shallow water created the conditions for the occurrence of the peat swamp and established the supra-tidal swampy facies. The environment for the accumulation of the major coal seams are analyzed. (In Chinese)

  9. Performance Evaluation of UPQC under Nonlinear Unbalanced Load Conditions Using Synchronous Reference Frame Based Control

    Science.gov (United States)

    Kota, Venkata Reddy; Vinnakoti, Sudheer

    2017-12-01

    Today, maintaining Power Quality (PQ) is very important in the growing competent world. With new equipments and devices, new challenges are also being put before power system operators. Unified Power Quality Conditioner (UPQC) is proposed to mitigate many power quality problems and to improve the performance of the power system. In this paper, an UPQC with Fuzzy Logic controller for capacitor voltage balancing is proposed in Synchronous Reference Frame (SRF) based control with Modified Phased Locked Loop (MPLL). The proposed controller with SRF-MPLL based control is tested under non-linear and unbalanced load conditions. The system is developed in Matlab/Simulink and its performance is analyzed under various conditions like non-linear, unbalanced load and polluted supply voltage including voltage sag/swells. Active and reactive power flow in the system, power factor and %THD of voltages and currents before and after compensation are also analyzed in this work. Results prove the applicability of the proposed scheme for power quality improvement. It is observed that the fuzzy controller gives better performance than PI controller with faster capacitor voltage balancing and also improves the dynamic performance of the system.

  10. An optimization strategy for the control of small capacity heat pump integrated air-conditioning system

    International Nuclear Information System (INIS)

    Gao, Jiajia; Huang, Gongsheng; Xu, Xinhua

    2016-01-01

    Highlights: • An optimization strategy for a small-scale air-conditioning system is developed. • The optimization strategy aims at optimizing the overall system energy consumption. • The strategy may guarantee the robust control of the space air temperature. • The performance of the optimization strategy was tested on a simulation platform. - Abstract: This paper studies the optimization of a small-scale central air-conditioning system, in which the cooling is provided by a ground source heat pump (GSHP) equipped with an on/off capacity control. The optimization strategy aims to optimize the overall system energy consumption and simultaneously guarantee the robustness of the space air temperature control without violating the allowed GSHP maximum start-ups number per hour specified by customers. The set-point of the chilled water return temperature and the width of the water temperature control band are used as the decision variables for the optimization. The performance of the proposed strategy was tested on a simulation platform. Results show that the optimization strategy can save the energy consumption by 9.59% in a typical spring day and 2.97% in a typical summer day. Meanwhile it is able to enhance the space air temperature control robustness when compared with a basic control strategy without optimization.

  11. Mitigating cutaneous sensation differences during tDCS: comparing sham versus low intensity control conditions.

    Science.gov (United States)

    Brunyé, Tad T; Cantelon, Julie; Holmes, Amanda; Taylor, Holly A; Mahoney, Caroline R

    2014-01-01

    Cutaneous sensations at electrode sites during the administration of direct current brain stimulation may inadvertently influence participants' subjective experience and task performance. The present study evaluated the utility of a methodological variation that substitutes sham administration with very low intensity (0.5 mA) current delivery. We used a 4 × 1 high-definition ring electrode transcranial direct current (HD-tDCS) system to target the left dorsolateral prefrontal cortex (Brodmann's Area 9). Four stimulation conditions were compared in a repeated-measures design: sham 2.0 mA and 0.5 mA intensity, versus active 2.0 mA and 0.5 mA intensity. During stimulation participants performed a cognitive interference task that activates the cingulo-frontal-parietal network, and periodically provided perceived sensation ratings. We demonstrate that a relatively low intensity control condition attenuates otherwise large differences in perceived sensation between active and sham conditions. Critically, behavioral task differences maintained between the two active conditions. A low intensity control stimulation condition may prove a viable methodological alternative to conventional sham techniques used in repeated-measures designs, though important limitations are discussed. Published by Elsevier Inc.

  12. Crack growth behaviour of low-alloy steels for pressure boundary components under transient light water reactor operating conditions - CASTOC, Part II: WWER conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ernestova, M.; Zamboch, M. [Nuclear Research Institute, NRI, Rez (Czech Republic); Devrient, B.; Roth, A. [Framatome ANP GmbH, Erlangen (Germany); Ehrnsten, U. [VTT Industrial Systems, Espoo (Finland); Foehl, J.; Weissenberg, T. [Staatliche Materialpruefungsanstalt, MPA, Stuttgart (Germany); Gomez-Briceno, D.; Lapena, J. [Centro de Investigaciones Energeticas Medioambientales y Tecnologicas, CIEMAT, Madrid (Spain); Ritter, S.; Seifert, H.P. [Paul Scherrer Institute, PSI, Villigen (Switzerland)

    2004-07-01

    One of the ageing phenomena of pressure boundary components of light water reactors (LWRs) is environmentally-assisted cracking (EAC). The project CASTOC (5. Framework Programme of the EU) was launched September 2000 with six European partners and terminated August 2003. It focused in particular on the EAC behaviour of low-alloy steels (LAS) and to some extent to weld metal, heat affected zone and the influence of an austenitic cladding. The main objective was directed to the clarification of crack growth behavior of LAS in high-temperature water due to EAC under constant load (steady-state power operation), to study the effect of transient conditions (during operation or start-up/shut-down of a plant) using their impact on time-based and cycle-based crack growth rates and to a more detailed understanding of the acting mechanisms. Autoclave tests were performed with Western and Russian type reactor pressure vessel steels under simulated boiling water reactor (BWR)/normal water chemistry (NWC) and pressurized water reactor (WWER) conditions. The investigations were performed with fracture mechanics specimens of different sizes and geometries. The applied loading comprised cyclic loads, static loads and load spectra where the static load was periodically interrupted by partial unloading. With regard to water chemistry, the oxygen content (WWER) and impurities of sulphate and chlorides (BWR) were varied beyond allowable limits for continuous operation. The current paper summarizes the most important crack growth results obtained under simulated WWER conditions. The influence of oxygen content and the effect of specimen size (C(T)25 versus C(T)50 specimens) on the crack growth rates are shown. The results are discussed in the context of the current crack growth rate curves in the corresponding nuclear codes. (authors)

  13. Crack growth behaviour of low-alloy steels for pressure boundary components under transient light water reactor operating conditions - CASTOC, Part II: WWER conditions

    International Nuclear Information System (INIS)

    Ernestova, M.; Zamboch, M.; Devrient, B.; Roth, A.; Ehrnsten, U.; Foehl, J.; Weissenberg, T.; Gomez-Briceno, D.; Lapena, J.; Ritter, S.; Seifert, H.P.

    2004-01-01

    One of the ageing phenomena of pressure boundary components of light water reactors (LWRs) is environmentally-assisted cracking (EAC). The project CASTOC (5. Framework Programme of the EU) was launched September 2000 with six European partners and terminated August 2003. It focused in particular on the EAC behaviour of low-alloy steels (LAS) and to some extent to weld metal, heat affected zone and the influence of an austenitic cladding. The main objective was directed to the clarification of crack growth behavior of LAS in high-temperature water due to EAC under constant load (steady-state power operation), to study the effect of transient conditions (during operation or start-up/shut-down of a plant) using their impact on time-based and cycle-based crack growth rates and to a more detailed understanding of the acting mechanisms. Autoclave tests were performed with Western and Russian type reactor pressure vessel steels under simulated boiling water reactor (BWR)/normal water chemistry (NWC) and pressurized water reactor (WWER) conditions. The investigations were performed with fracture mechanics specimens of different sizes and geometries. The applied loading comprised cyclic loads, static loads and load spectra where the static load was periodically interrupted by partial unloading. With regard to water chemistry, the oxygen content (WWER) and impurities of sulphate and chlorides (BWR) were varied beyond allowable limits for continuous operation. The current paper summarizes the most important crack growth results obtained under simulated WWER conditions. The influence of oxygen content and the effect of specimen size (C(T)25 versus C(T)50 specimens) on the crack growth rates are shown. The results are discussed in the context of the current crack growth rate curves in the corresponding nuclear codes. (authors)

  14. Quality control for digital mammography: Part II recommendations from the ACRIN DMIST trial

    International Nuclear Information System (INIS)

    Yaffe, Martin J.; Bloomquist, Aili K.; Mawdsley, Gordon E.

    2006-01-01

    The Digital Mammography Imaging Screening Trial (DMIST), conducted under the auspices of the American College of Radiology Imaging Network (ACRIN), is a clinical trial designed to compare the accuracy of digital versus screen-film mammography in a screening population [E. Pisano et al., ACRIN 6652--Digital vs. Screen-Film Mammography, ACRIN (2001)]. Part I of this work described the Quality Control program developed to ensure consistency and optimal operation of the digital equipment. For many of the tests, there were no failures during the 24 months imaging was performed in DMIST. When systems failed, they generally did so suddenly rather than through gradual deterioration of performance. In this part, the utility and effectiveness of those tests are considered. This suggests that after verification of proper operation, routine extensive testing would be of minimal value. A recommended set of tests is presented including additional and improved tests, which we believe meet the intent and spirit of the Mammography Quality Standards Act regulations to ensure that full-field digital mammography systems are functioning correctly, and consistently producing mammograms of excellent image quality

  15. Duct corrosion in the ventilating air conditioning system for Main Control Room

    International Nuclear Information System (INIS)

    Yamada, Kohei; Kobayashi, Takashi; Minami, Akiko; Fukuba, Kazushi

    2014-01-01

    Higashidori Nuclear Power Station, start-of-operation in December 2005, is a relatively new plant. We decided to get original data of air duct condition to determine maintenance policy of air duct, because planned maintenance of air duct has never been done and the corrosion of air duct has occurred in other plant. In January 2014, we found a corrosion-hole at the downstream of the inlet damper in the ventilating air conditioning system for Main Control Room (MCR). We supposed that the cause of rapid corrosion is related to the characteristic environment of this site. (author)

  16. Controlling the anodizing conditions in preparation of an nanoporous anodic aluminium oxide template

    Science.gov (United States)

    Nazemi, Azadeh; Abolfazl, Seyed; Sadjadi, Seyed

    2014-12-01

    Porous anodic aluminium oxide (AAO) template is commonly used in the synthesis of one-dimensional nanostructures, such as nanowires and nanorods, due to its simple fabrication process. Controlling the anodizing conditions is important because of their direct influence on the size of AAO template pores; it affects the size of nanostructures that are fabricated in AAO template. In present study, several alumina templates were fabricated by a two-step electrochemical anodization in different conditions, such as the time of first process, its voltage, and electrolyte concentration. The effect of these factors on pore diameters of AAO templates was investigated using scanning electron microscopy (SEM).

  17. Incorporating fan control into air-conditioning systems to improve energy efficiency and transient response

    International Nuclear Information System (INIS)

    Yeh, T.-J.; Chen, Yun-Jih; Hwang, Wei-Yang; Lin, Jin-Long

    2009-01-01

    Modern air-conditioners frequently incorporate variable-speed compressors and variable-opening expansion valves with feedback control to improve performance and power efficiency. Because making the fan speeds adjustable adds flexibility to the control design and thus can lead to further improvements in performance and efficiency, this paper proposes two control algorithms, respectively, incorporating the outdoor fan and the indoor fan as the additional control inputs for air-conditioning systems. Both of the control algorithms are designed based on a low-order, linear model obtained from system identification. The first algorithm, which modulates the outdoor fan speed, can reduce the steady state power consumption if the temperature difference between the condenser and the outdoor environment is controlled properly. The second algorithm, which adds one more degree of freedom to control by modulating the indoor fan speed, can improve the transient response because actuator saturations become less likely to occur. The two control algorithms are implemented on a split-type residential air-conditioner and their respective performance is validated experimentally.

  18. Mode switching control of dual-evaporator air-conditioning systems

    International Nuclear Information System (INIS)

    Lin, J.-L.; Yeh, T.-J.

    2009-01-01

    Modern air-conditioners incorporate variable-speed compressors and variable-opening expansion valves as the actuators for improving cooling performance and energy efficiency. These actuators have to be properly feedback-controlled; otherwise the systems may exhibit even poorer performance than the conventional machines which use fixed-speed compressors and mechanical expansion valves. Particularly for an air-conditioner with multiple evaporators, there are occasions that the machine is operated in a mode that only selected evaporator(s) is(are) turned on, and switching(s) between modes occurs(occur) during the control process. In this case, one needs to have more carefully designed control and switching strategies to ensure the system performance. In this paper, a framework for mode switching control of the dual-evaporator air-conditioning (DEAC) system is proposed. The framework is basically an integration of a controller and a dynamic compensator. The controller, which possesses the flow-distribution capability and assumes both evaporators are on throughout the control process, is intended to provide nominal performance. While mode switching is achieved by varying the reference settings in the controller, the dynamic compensator is used to improve the transient responses immediately after the switching. Experiments indicate that the proposed framework can achieve satisfactory indoor temperature regulation and provide bumpless switching between different modes of operation.

  19. Improving safety margins for control room habitability, through heating/ventilation/air conditioning modifications

    International Nuclear Information System (INIS)

    Beach, D.R.; Fillingim, W.; Bell, G.; Eurich, R.G.

    1989-01-01

    The Fort Calhoun power station began operation in September 1973. Since that time, modifications to the plant have required the addition of a substantial number of electrical and control components in the control room, which has resulted in an increased heat load in this area. Additionally, NUREG-0737, Item III.D.3.4, imposed requirements on the ventilating system related to protection of personnel from the effects of toxic and radioactive gas releases, which were not considered in the original design. Omaha Public Power District (OPPD) has recently undertaken a major modification to the Fort Calhoun station control room ventilating system to improve the safety margins for control room habitability. The goals of the modification were to achieve adequate cooling capacity with fully redundant equipment, improve habitability under accident conditions, and eliminate several potential problems related to steam line break and equipment qualification. Additionally, the scope of the project grew as design problems emerged

  20. Biological control of white mold by Trichoderma harzianum in common bean under field conditions

    Directory of Open Access Journals (Sweden)

    Daniel Diego Costa Carvalho

    2015-12-01

    Full Text Available Abstract: The objective of this work was to evaluate Trichoderma harzianum isolates for biological control of white mold in common bean (Phaseolus vulgaris. Five isolates were evaluated for biocontrol of white mold in 'Perola' common bean under field conditions, in the 2009 and 2010 crop seasons. A commercial isolate (1306 and a control treatment were included. Foliar applications at 2x109 conidia mL-1 were performed at 42 and 52 days after sowing (DAS, in 2009, and at 52 DAS in 2010. The CEN287, CEN316, and 1306 isolates decreased the number of Sclerotinia sclerotiorum apothecia per square meter in comparison to the control, in both crop seasons. CEN287, CEN316, and 1306 decreased white mold severity during the experimental period, when compared to the control.

  1. Control of hybrid AC/DC microgrid under islanding operational conditions

    DEFF Research Database (Denmark)

    Ding, G.; Gao, F.; Zhang, S.

    2014-01-01

    This paper presents control methods for hybrid AC/DC microgrid under islanding operation condition. The control schemes for AC sub-microgrid and DC sub-microgrid are investigated according to the power sharing requirement and operational reliability. In addition, the key control schemes...... of interlinking converter with DC-link capacitor or energy storage, which will devote to the proper power sharing between AC and DC sub-microgrids to maintain AC and DC side voltage stable, is reviewed. Combining the specific control methods developed for AC and DC sub-microgrids with interlinking converter......, the whole hybrid AC/DC microgrid can manage the power flow transferred between sub-microgrids for improving on the operational quality and efficiency....

  2. Age-related effects on postural control under multi-task conditions.

    Science.gov (United States)

    Granacher, Urs; Bridenbaugh, Stephanie A; Muehlbauer, Thomas; Wehrle, Anja; Kressig, Reto W

    2011-01-01

    Changes in postural sway and gait patterns due to simultaneously performed cognitive (CI) and/or motor interference (MI) tasks have previously been reported and are associated with an increased risk of falling in older adults. The objectives of this study were to investigate the effects of a CI and/or MI task on static and dynamic postural control in young and elderly subjects, and to find out whether there is an association between measures of static and dynamic postural control while concurrently performing the CI and/or MI task. A total of 36 healthy young (n = 18; age: 22.3 ± 3.0 years; BMI: 21.0 ± 1.6 kg/m(2)) and elderly adults (n = 18; age: 73.5 ± 5.5 years; BMI: 24.2 ± 2.9 kg/m(2)) participated in this study. Static postural control was measured during bipedal stance, and dynamic postural control was obtained while walking on an instrumented walkway. Irrespective of the task condition, i.e. single-task or multiple tasks, elderly participants showed larger center-of-pressure displacements and greater stride-to-stride variability than younger participants. Associations between measures of static and dynamic postural control were found only under the single-task condition in the elderly. Age-related deficits in the postural control system seem to be primarily responsible for the observed results. The weak correlations detected between static and dynamic measures could indicate that fall-risk assessment should incorporate dynamic measures under multi-task conditions, and that skills like erect standing and walking are independent of each other and may have to be trained complementarily. Copyright © 2010 S. Karger AG, Basel.

  3. Optimal control of the process of cultivation in the conditions of infection

    Directory of Open Access Journals (Sweden)

    N. V. Sukhanova

    2016-01-01

    Full Text Available The article presents a way of solving of the optimal control problem of antibiotic feeding under condition of infection, consisting in the selection of the optimal control in the field of admissible control, with the aim of achieving a compromise between the losses in production due to the presence of foreign microflora, and the cost of its suppression due to the application of antibiotic. The presence of other microorganisms in the finished product, in particular of the “wild“ ones, considerably impairs the quality indicators of the final product (in particular, it reduces the storage time. In peculiar conditions of production it is possible to improve the quality of target product due to elimination of infection, including, when used antibiotics in the process of cultivation, but due to the lack of efficient algorithms and control systems of their supply the question is still open. We use the system of Lotka-Volterra adapted for microbiological process as a mathematical model adequately describing the situation of competitive interaction of two populations of microorganisms (useful and “wild“ ones due to the consumption of one resource. The aim is to find a control law U(t belonging to the field of admissible control. The control that affords minimum to the optimization criterion in accordance with the principle of maximum is defined by the condition of the maximum of Hamilton function and the resulting canonical system of equations. The modified conjugated system of equations in matrix form is obtained. The solution of system of differential-different equations in the analytical form is found using the method of coordinate transformation. As a result an optimal control law is found (with regard to the selected criterion. This is the control law of application of the antibiotic, allowing to control the concentration of foreign microflora in the process of cultivation of microorganisms and accounting for the specific

  4. Controlling the site density of multiwall carbon nanotubes via growth conditions

    Science.gov (United States)

    Siegal, M. P.; Overmyer, D. L.; Kaatz, F. H.

    2004-06-01

    We present two complementary methods for controlling the site density of multiwall carbon nanotubes (CNTs) directly as a function of growth conditions from 1011to107CNTs/cm2. Several potential applications require significant spacing between individual CNTs. The first method shows that the site density varies with the heat of formation of the hydrocarbon gas used during CNT growth by thermal chemical vapor deposition. The second method demonstrates that the site density decreases with increasing residual stress of the metal catalyst/diffusion barrier layers. These methods are combined for wide-range control of CNT site density.

  5. Enhanced Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid-Voltage Conditions

    DEFF Research Database (Denmark)

    Reyes, M.; Rodriguez, Pedro; Vazquez, S.

    2012-01-01

    . In these codes, the injection of positive- and negative-sequence current components becomes necessary for fulfilling, among others, the low-voltage ride-through requirements during balanced and unbalanced grid faults. However, the performance of classical dq current controllers, applied to power converters......, under unbalanced grid-voltage conditions is highly deficient, due to the unavoidable appearance of current oscillations. This paper analyzes the performance of the double synchronous reference frame controller and improves its structure by adding a decoupling network for estimating and compensating...

  6. A Study of Active Rotor-Blade Vibration Control using Electro-Magnetic Actuation - Part II: Experiment

    DEFF Research Database (Denmark)

    Christensen, Rene Hardam; Santos, Ilmar

    2004-01-01

    . The remaining two sets of actuators are applied to act directly onto the hub, working as an active radial bearing controlling the rotor lateral movement. The rig is equipped with sensors measuring blade and rotor vibrations. Actuators and sensors are connected to a digital signal processor running the control......This is the second paper in a two-part study on active rotor-blade vibration control. This part presents an experimental contribution into the work of active controller design for rotor-blade systems. The primary aim is to give an experimental validation and show the applicability...... algorithm. Measurement signals and actuator control signals from the sensors and actuators fixed in the rotating disc are transmitted to the control unit through a slip-ring device. Various measured responses of both the controlled and the non-controlled system with identical blades and with deliberately...

  7. Thermoelectric properties control due to doping level and sintering conditions for FGM thermoelectric element

    CERN Document Server

    Kajikawa, T; Shiraishi, K; Ohmori, M; Hirai, T

    1999-01-01

    Thermoelectric performance is determined with three factors, namely, Seebeck coefficient, electrical resistivity and thermal conductivity. For metal and single crystalline semiconductor, those factors have close interrelation each $9 other. However, as the sintered thermoelectric element has various levels of superstructure from macro scale and micro scale in terms of the thermoelectric mechanism, the relationship among them is more complex than that for the $9 melt- grown element, so it is suggested that the control of the temperature dependence of thermoelectric properties is possible to enhance the thermoelectric performance for wide temperature range due to FGM approach. The research $9 objective is to investigate the characteristics of the thermoelectric properties for various doping levels and hot-pressed conditions to make the thermoelectric elements for which the temperature dependence of the performance is $9 controlled due to FGM approach varying the doping levels and sintering conditions. By usage ...

  8. PATs Operating in Water Networks under Unsteady Flow Conditions: Control Valve Manoeuvre and Overspeed Effect

    Directory of Open Access Journals (Sweden)

    Modesto Pérez-Sánchez

    2018-04-01

    Full Text Available The knowledge of transient conditions in water pressurized networks equipped with pump as turbines (PATs is of the utmost importance and necessary for the design and correct implementation of these new renewable solutions. This research characterizes the water hammer phenomenon in the design of PAT systems, emphasizing the transient events that can occur during a normal operation. This is based on project concerns towards a stable and efficient operation associated with the normal dynamic behaviour of flow control valve closure or by the induced overspeed effect. Basic concepts of mathematical modelling, characterization of control valve behaviour, damping effects in the wave propagation and runaway conditions of PATs are currently related to an inadequate design. The precise evaluation of basic operating rules depends upon the system and component type, as well as the required safety level during each operation.

  9. Towards artificial intelligence based diesel engine performance control under varying operating conditions using support vector regression

    Directory of Open Access Journals (Sweden)

    Naradasu Kumar Ravi

    2013-01-01

    Full Text Available Diesel engine designers are constantly on the look-out for performance enhancement through efficient control of operating parameters. In this paper, the concept of an intelligent engine control system is proposed that seeks to ensure optimized performance under varying operating conditions. The concept is based on arriving at the optimum engine operating parameters to ensure the desired output in terms of efficiency. In addition, a Support Vector Machines based prediction model has been developed to predict the engine performance under varying operating conditions. Experiments were carried out at varying loads, compression ratios and amounts of exhaust gas recirculation using a variable compression ratio diesel engine for data acquisition. It was observed that the SVM model was able to predict the engine performance accurately.

  10. Managing emergencies and abnormal situations in air traffic control (part II): teamwork strategies.

    Science.gov (United States)

    Malakis, Stathis; Kontogiannis, Tom; Kirwan, Barry

    2010-07-01

    Team performance has been studied in many safety-critical organizations including aviation, nuclear power plant, offshore oil platforms and health organizations. This study looks into teamwork strategies that air traffic controllers employ to manage emergencies and abnormal situations. Two field studies were carried out in the form of observations of simulator training in emergency and unusual scenarios of novices and experienced controllers. Teamwork strategies covered aspects of team orientation and coordination, information exchange, change management and error handling. Several performance metrics were used to rate the efficiency of teamwork and test the construct validity of a prototype model of teamwork. This is a companion study to an earlier investigation of taskwork strategies in the same field (part I) and contributes to the development of a generic model for Taskwork and Teamwork strategies in Emergencies in Air traffic Management (T(2)EAM). Suggestions are made on how to use T(2)EAM to develop training programs, assess team performance and improve mishap investigations. Copyright 2010 Elsevier Ltd. All rights reserved.

  11. Energy Performance and Optimal Control of Air-conditioned Buildings Integrated with Phase Change Materials

    Science.gov (United States)

    Zhu, Na

    This thesis presents an overview of the previous research work on dynamic characteristics and energy performance of buildings due to the integration of PCMs. The research work on dynamic characteristics and energy performance of buildings using PCMs both with and without air-conditioning is reviewed. Since the particular interest in using PCMs for free cooling and peak load shifting, specific research efforts on both subjects are reviewed separately. A simplified physical dynamic model of building structures integrated with SSPCM (shaped-stabilized phase change material) is developed and validated in this study. The simplified physical model represents the wall by 3 resistances and 2 capacitances and the PCM layer by 4 resistances and 2 capacitances respectively while the key issue is the parameter identification of the model. This thesis also presents the studies on the thermodynamic characteristics of buildings enhanced by PCM and on the investigation of the impacts of PCM on the building cooling load and peak cooling demand at different climates and seasons as well as the optimal operation and control strategies to reduce the energy consumption and energy cost by reducing the air-conditioning energy consumption and peak load. An office building floor with typical variable air volume (VAV) air-conditioning system is used and simulated as the reference building in the comparison study. The envelopes of the studied building are further enhanced by integrating the PCM layers. The building system is tested in two selected cities of typical climates in China including Hong Kong and Beijing. The cold charge and discharge processes, the operation and control strategies of night ventilation and the air temperature set-point reset strategy for minimizing the energy consumption and electricity cost are studied. This thesis presents the simulation test platform, the test results on the cold storage and discharge processes, the air-conditioning energy consumption and demand

  12. Radiation protection at the RA Reactor in 1988, Part -2, Annex 2c, Environmental radioactivity control, meteorology measurements

    International Nuclear Information System (INIS)

    Grsic, Z.; Zaric, M.; Adamovic, M.; Stevanovic, M.

    1988-01-01

    During 1988, meteorology measurements were continued as a part of the environmental control of the Vinca Institute. This report covers the period from November 1984 - November 1985. Part of the meteorology measurements and data analysis is adapted to the needs of the Institute, i.e. RA reactor and some Laboratories. The objective of these activities is forming the data base for solving everyday and special problems related to control, protection and safety of Institute environment [sr

  13. Which key properties controls the preferential transport in the vadose zone under transient hydrological conditions

    Science.gov (United States)

    Groh, J.; Vanderborght, J.; Puetz, T.; Gerke, H. H.; Rupp, H.; Wollschlaeger, U.; Stumpp, C.; Priesack, E.; Vereecken, H.

    2015-12-01

    % arrival time and potential key soil properties, site factors and boundary conditions will be presented in order to identify key properties which control the preferential transport in the vadose zone under transient hydrological conditions.

  14. Controls of multi-modal wave conditions in a complex coastal setting

    Science.gov (United States)

    Hegermiller, Christie; Rueda, Ana C.; Erikson, Li H.; Barnard, Patrick L.; Antolinez, J.A.A.; Mendez, Fernando J.

    2017-01-01

    Coastal hazards emerge from the combined effect of wave conditions and sea level anomalies associated with storms or low-frequency atmosphere-ocean oscillations. Rigorous characterization of wave climate is limited by the availability of spectral wave observations, the computational cost of dynamical simulations, and the ability to link wave-generating atmospheric patterns with coastal conditions. We present a hybrid statistical-dynamical approach to simulating nearshore wave climate in complex coastal settings, demonstrated in the Southern California Bight, where waves arriving from distant, disparate locations are refracted over complex bathymetry and shadowed by offshore islands. Contributions of wave families and large-scale atmospheric drivers to nearshore wave energy flux are analyzed. Results highlight the variability of influences controlling wave conditions along neighboring coastlines. The universal method demonstrated here can be applied to complex coastal settings worldwide, facilitating analysis of the effects of climate change on nearshore wave climate.

  15. Data support system for controlling decentralised nuclear power industry facilities through uninterruptible condition monitoring

    Directory of Open Access Journals (Sweden)

    Povarov Vladimir

    2018-01-01

    Full Text Available The article describes the automated uninterruptible multi-parameter system for monitoring operational vulnerability of critical NPP components, which differs from existing ones by being universally applicable for analysing mechanical damage of nuclear power unit components. The system allows for performing routine assessment of metal structures. The assessment of strained condition of a deteriorating component is based on three-dimensional finite element simulation with calculations adjusted with reference to in-situ measurements. A program for calculation and experimental analysis of maximum load and durability of critical area forms the core of uninterruptible monitoring system. The knowledge base on performance of the monitored components in different operating conditions and the corresponding comprehensive analysis of strained condition and deterioration rates compose the basis of control system data support, both for operating nuclear power units and robotic maintenance and repair systems.

  16. Adaptive Fuzzy Logic based MPPT Control for PV System Under Partial Shading Condition

    OpenAIRE

    Choudhury, Subhashree; Rout, Pravat Kumar

    2016-01-01

    Partial shading causes power loss, hotspots and threatens the reliability of the Photovoltaic generation system. Moreover characteristic curves exhibit multiple peaks. Conventional MPPT techniques under this condition often fail to give optimum MPP. Focusing on the afore mentioned problem an attempt has been made to design an Adaptive Takagi-Sugeno Fuzzy Inference System based Fuzzy Logic Control MPPT.The mathematical model of PV array is simulated using in MATLAB/Simulink environment.Various...

  17. Microprocessor supervised stability control system for the united power system of Middle Volga in fault conditions

    Energy Technology Data Exchange (ETDEWEB)

    Berdnikov, V I; Birgel, E R; Kovalev, V D; Kuznestov, A N

    1994-12-31

    The development of the 500 kV UPS of Middle Volga, the complication of its configuration and operating conditions particularly in connection with concentration of the generating power at Balakovo NPS have aggravated the problem of stability of the Middle Volga UPS when high power is transmitted along the 500 kV transient system. In this case the necessity for improving control actions` dosage accuracy has also appeared. This work discusses solution to the above mentioned issue. (author) 3 figs.

  18. A Question of Control? Examining the Role of Control Conditions in Experimental Psychopathology using the Example of Cognitive Bias Modification Research.

    Science.gov (United States)

    Blackwell, Simon E; Woud, Marcella L; MacLeod, Colin

    2017-10-26

    While control conditions are vitally important in research, selecting the optimal control condition can be challenging. Problems are likely to arise when the choice of control condition is not tightly guided by the specific question that a given study aims to address. Such problems have become increasingly apparent in experimental psychopathology research investigating the experimental modification of cognitive biases, particularly as the focus of this research has shifted from theoretical questions concerning mechanistic aspects of the association between cognitive bias and emotional vulnerability, to questions that instead concern the clinical efficacy of 'cognitive bias modification' (CBM) procedures. We discuss the kinds of control conditions that have typically been employed in CBM research, illustrating how difficulties can arise when changes in the types of research questions asked are not accompanied by changes in the control conditions employed. Crucially, claims made on the basis of comparing active and control conditions within CBM studies should be restricted to those conclusions allowed by the specific control condition employed. CBM studies aiming to establish clinical utility are likely to require quite different control conditions from CBM studies aiming to illuminate mechanisms. Further, conclusions concerning the clinical utility of CBM interventions cannot necessarily be drawn from studies in which the control condition has been chosen to answer questions concerning mechanisms. Appreciating the need to appropriately alter control conditions in the transition from basic mechanisms-focussed investigations to applied clinical research could greatly facilitate the translational process.

  19. Remote Supervision and Control of Air Conditioning Systems in Different Modes

    Science.gov (United States)

    Rafeeq, Mohammed; Afzal, Asif; Rajendra, Sree

    2018-01-01

    In the era of automation, most of the application of engineering and science are interrelated with system for optimal operation. To get the efficient result of an operation and desired response, interconnected systems should be controlled by directing, regulating and commanding. Here, air conditioning (AC) system is considered for experimentation, to supervise and control its functioning in both, automated and manual mode. This paper reports the work intended to design and develop an automated and manual AC system working in remote and local mode, to increase the level of comfort, easy operation, reducing human intervention and faults occurring in the system. The Programmable Logical Controller (PLC) and Supervisory Control and Data Acquisition (SCADA) system were used for remote supervision and monitoring of AC systems using series ninety protocol and remote terminal unit modbus protocol as communication module to operate in remote mode. PLC was used as remote terminal for continuous supervision and control of AC system. SCADA software was used as a tool for designing user friendly graphical user interface. The proposed SCADA AC system successfully monitors and controls in accordance within the parameter limits like temperature, pressure, humidity and voltage. With all the features, this designed system is capable of efficient handling of the resources like the compressor, humidifier etc., with all the levels of safety and durability. This system also maintains the temperature and controls the humidity of the remote location and also looks after the health of the compressor.

  20. LQG/LTR optimal attitude control of small flexible spacecraft using free-free boundary conditions

    Science.gov (United States)

    Fulton, Joseph M.

    Due to the volume and power limitations of a small satellite, careful consideration must be taken while designing an attitude control system for 3-axis stabilization. Placing redundancy in the system proves difficult and utilizing power hungry, high accuracy, active actuators is not a viable option. Thus, it is customary to find dependable, passive actuators used in conjunction with small scale active control components. This document describes the application of Elastic Memory Composite materials in the construction of a flexible spacecraft appendage, such as a gravity gradient boom. Assumed modes methods are used with Finite Element Modeling information to obtain the equations of motion for the system while assuming free-free boundary conditions. A discussion is provided to illustrate how cantilever mode shapes are not always the best assumption when modeling small flexible spacecraft. A key point of interest is first resonant modes may be needed in the system design plant in spite of these modes being greater than one order of magnitude in frequency when compared to the crossover frequency of the controller. LQG/LTR optimal control techniques are implemented to compute attitude control gains while controller robustness considerations determine appropriate reduced order controllers and which flexible modes to include in the design model. Key satellite designer concerns in the areas of computer processor sizing, material uncertainty impacts on the system model, and system performance variations resulting from appendage length modifications are addressed.

  1. Production and quality control of concrete for the Rajasthan Atomic Power Station - [Part 1

    International Nuclear Information System (INIS)

    Singha Roy, P.K.; Sukhtankar, K.D.; Prasad, K.

    1975-01-01

    The production and quality control of concrete and concrete materials for the construction of the twin-reactor Rajasthan Atomic Power Station with its 400 MW net capacity posed many challenges since many of the requirements for the properties of concrete were new and were being laid down for the first time in India. Some of the conditions for the concrete included leak-tightness against gas pressure, total absence of shrinkage in the containment even when the ambient temperature during concreting was as high as 45degC, placing concrete at a temperature as low as 8degC, the use of non-shrink and high strength grout, absolute impermeability against water, high density for radiation shielding, controlled modulus of elasticity for large machine foundations, high strength with high slump for the prestressed concrete dome, etc. Though the total quantity of concrete was not very much compared with a large river valley or steel plant project, (e.g., about 1.2 X 10 6 m 3 for a 2-million tonne steel plant) it was quite significant, being about 70,000 m 3 of normal density and 2,100 m 3 of high density concrete. The production of these quantities entailed intensive material study and investigation, development of new mixes with additives not tried out before in the country, and design and quality control techniques which were unique in many respects. The paper deals with the production and quality control of concrete, including grouts used in the projects, but the actual concreting and construction operations are not discussed. (author)

  2. Techno-economic comparison of combined cycle gas turbines with advanced membrane configuration and MEA solvent at part load conditions

    NARCIS (Netherlands)

    Van Der Spek, Mijndert; Bonalumi, Davide; Manzolini, Giampaolo; Ramirez, Andrea; Faaij, André P.C.

    2018-01-01

    This work compares the part load techno-economic performance of CO2 capture from a CCGT using a membrane configuration with selective CO2 recycle and using MEA solvent, under the assumption of flexible power plant dispatch. This is the first time that the techno-economic performance of CO2 capture

  3. Sedimentary facies and lithologic characters as main factors controlling hydrocarbon accumulations and their critical conditions

    Directory of Open Access Journals (Sweden)

    Jun-Qing Chen

    2015-10-01

    Full Text Available Taking more than 1000 clastic hydrocarbon reservoirs of Bohai Bay Basin, Tarim Basin and Junggar Basin, China as examples, the paper has studied the main controlling factors of hydrocarbon reservoirs and their critical conditions to reveal the hydrocarbon distribution and to optimize the search for favorable targets. The results indicated that the various sedimentary facies and lithologic characters control the critical conditions of hydrocarbon accumulations, which shows that hydrocarbon is distributed mainly in sedimentary facies formed under conditions of a long-lived and relatively strong hydrodynamic environment; 95% of the hydrocarbon reservoirs and reserves in the three basins is distributed in siltstones, fine sandstones, lithified gravels and pebble-bearing sandstones; moreover, the probability of discovering conventional hydrocarbon reservoirs decreases with the grain size of the clastic rock. The main reason is that the low relative porosity and permeability of fine-grained reservoirs lead to small differences in capillary force compared with surrounding rocks small and insufficiency of dynamic force for hydrocarbon accumulation; the critical condition for hydrocarbon entering reservoir is that the interfacial potential in the surrounding rock (Φn must be more than twice of that in the reservoir (Φs; the probability of hydrocarbon reservoirs distribution decreases in cases where the hydrodynamic force is too high or too low and when the rocks have too coarse or too fine grains.

  4. 77 FR 57039 - Special Conditions: Embraer S.A., Model EMB-550 Airplane; Electronic Flight Control System...

    Science.gov (United States)

    2012-09-17

    ... Flight Control System: Control Surface Awareness and Mode Annunciation AGENCY: Federal Aviation... a fly-by-wire electronic flight control system and no direct coupling from the flightdeck controller... nuisance alerting. This special condition also addresses flight control system mode annunciation. It...

  5. Flap controllers applied on the OffshoreWindChina (OWC) 5MW reference wind turbine for Chinese typhoon conditions

    DEFF Research Database (Denmark)

    Barlas, Athanasios

    The report describes the development of flap controllers applied on the OffshoreWindChina (OWC) 5MW reference wind turbine for Chinese typhoon conditions. Optimal flap controllers are designed and tuned based on linear aeroelastic models from HawcStab2. The controllers are evaluated in normal......, parked and storm conditions, targeting the alleviation of fatigue and extreme loads....

  6. A complex study on the reliability assessment of the containment of a PWR. Part III.- Structural reliability assessment under internal and external loading conditions

    International Nuclear Information System (INIS)

    Bauer, J.; Schueller, G.I.

    1977-01-01

    The first part of the analysis is concerned with the determination of the failure probability of the steel hull under internal load conditions. Two independent failure criteria are the basis for this calculation; the first one being the ultimate yield which is actually an instability condition and the second one being the fracture condition as described in Part II of the paper. Both the global and the local failure probabilities are investigated. The second part of the analysis is concerned with the external load case of earthquake. As it has already been described in Part I the probability of occurrence of a LOCA, given an earthquake has been considered in connection with the probable damage which the steel hull might experience during the earthquake. In other words the survival probability of the hull with deteriorated resistance is calculated, taking into account the frequencies of occurrence of the various events. The third part of the analysis is concerned with the reliability determination of the reinforced concrete dome structure, which is supposed to protect, the steel hull against external load conditions such as airplane crash and external pressure waves (the latter covering the load case of tornado occurrence). The reliability analysis of the reinforced concrete structure under earthquake loading is performed by utilizing the time-history method. Some aspects of the drawbacks of the response spectra method -when used in a risk analysis- are pointed out. The probability distribution of the concrete strength as determined under intermediate strain rate as described in Part II is utilized in the analysis. Finally the remaining two external load cases are discussed in light of their use in a reliability analysis and with respect to their frequency of occurrence and the probability distribution of their load intensities. The reliability demonstration is performed using the containment structure of the PWR-plant 'Biblis B' which is locate

  7. A Novel Distributed Economic Model Predictive Control Approach for Building Air-Conditioning Systems in Microgrids

    Directory of Open Access Journals (Sweden)

    Xinan Zhang

    2018-04-01

    Full Text Available With the penetration of grid-connected renewable energy generation, microgrids are facing stability and power quality problems caused by renewable intermittency. To alleviate such problems, demand side management (DSM of responsive loads, such as building air-conditioning system (BACS, has been proposed and studied. In recent years, numerous control approaches have been published for proper management of single BACS. The majority of these approaches focus on either the control of BACS for attenuating power fluctuations in the grid or the operating cost minimization on behalf of the residents. These two control objectives are paramount for BACS control in microgrids and can be conflicting. As such, they should be considered together in control design. As individual buildings may have different owners/residents, it is natural to control different BACSs in an autonomous and self-interested manner to minimize the operational costs for the owners/residents. Unfortunately, such “selfish” operation can result in abrupt and large power fluctuations at the point of common coupling (PCC of the microgrid due to lack of coordination. Consequently, the original objective of mitigating power fluctuations generated by renewable intermittency cannot be achieved. To minimize the operating costs of individual BACSs and simultaneously ensure desirable overall power flow at PCC, this paper proposes a novel distributed control framework based on the dissipativity theory. The proposed method achieves the objective of renewable intermittency mitigation through proper coordination of distributed BACS controllers and is scalable and computationally efficient. Simulation studies are carried out to illustrate the efficacy of the proposed control framework.

  8. Mechanical behaviour of a fuel cell stack under vibrating conditions linked to aircraft applications part II: Three-dimensional modelling

    Energy Technology Data Exchange (ETDEWEB)

    Rouss, Vicky; Charon, Willy [M3M, University of Technology Belfort - Montbeliard (France); FCLAB, Rue Thierry Mieg, F 90010 Belfort, Cedex (France); Candusso, Denis [INRETS, The French National Institute for Transport and Safety Research (France); FCLAB, Rue Thierry Mieg, F 90010 Belfort, Cedex (France)

    2008-11-15

    The implementation of fuel cells (FC) in transportation systems such as airplanes requires better understanding of their mechanical behaviour in vibrating environment. To this end, a FC stack was tested on a vibrating platform for all three orthogonal axes. The experimental procedure is described in the first part of the paper. This second part of the paper demonstrates how the experimental data collected can be used to create a three-dimensional, multi-input and multi-output model based on the Artificial Neural Network (ANN) approach. Indeed FCs are nonlinear mechanical systems, difficult to be physically modelled. The ANN methodology which depends strictly on raw data is a particularly interesting alternative solution to model FCs, for example, for monitoring purpose. The ANN model is described along with the training, pruning and validation stages. The results are exposed and commented. (author)

  9. Physics conditions for robust control of tearing modes in a rotating tokamak plasma

    Science.gov (United States)

    Lazzaro, E.; Borgogno, D.; Brunetti, D.; Comisso, L.; Fevrier, O.; Grasso, D.; Lutjens, H.; Maget, P.; Nowak, S.; Sauter, O.; Sozzi, C.; the EUROfusion MST1 Team

    2018-01-01

    The disruptive collapse of the current sustained equilibrium of a tokamak is perhaps the single most serious obstacle on the path toward controlled thermonuclear fusion. The current disruption is generally too fast to be identified early enough and tamed efficiently, and may be associated with a variety of initial perturbing events. However, a common feature of all disruptive events is that they proceed through the onset of magnetohydrodynamic instabilities and field reconnection processes developing magnetic islands, which eventually destroy the magnetic configuration. Therefore the avoidance and control of magnetic reconnection instabilities is of foremost importance and great attention is focused on the promising stabilization techniques based on localized rf power absorption and current drive. Here a short review is proposed of the key aspects of high power rf control schemes (specifically electron cyclotron heating and current drive) for tearing modes, considering also some effects of plasma rotation. From first principles physics considerations, new conditions are presented and discussed to achieve control of the tearing perturbations by means of high power ({P}{{EC}}≥slant {P}{{ohm}}) in regimes where strong nonlinear instabilities may be driven, such as secondary island structures, which can blur the detection and limit the control of the instabilities. Here we consider recent work that has motivated the search for the improvement of some traditional control strategies, namely the feedback schemes based on strict phase tracking of the propagating magnetic islands.

  10. Comparison of theoretical estimates and experimental measurements of fatigue crack growth under severe thermal shock conditions (part one - experimental observations)

    International Nuclear Information System (INIS)

    Marsh, D.; Green, D.; Parker, R.

    1984-01-01

    This paper reports the results of an experiment in which a severe thermal cycle comprising of alternate upshocks and downshocks has been applied to an axisymmetric feature with an internal, partial penetration weld and crevice. The direction of cracking and crack growth rate were observed experimentally and detailed records made of the thermal cycle. A second part to the paper, reported separately, compares a linear elastic fracture mechanics assessment of the cracking to the experimental observations

  11. Hyperglycemic conditions inhibit C3-mediated immunologic control of Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Hair Pamela S

    2012-03-01

    Full Text Available Abstract Background Diabetic patients are at increased risk for bacterial infections; these studies provide new insight into the role of the host defense complement system in controlling bacterial pathogens in hyperglycemic environments. Methods The interactions of complement C3 with bacteria in elevated glucose were assayed for complement activation to opsonic forms, phagocytosis and bacterial killing. C3 was analyzed in euglycemic and hyperglycemic conditions by mass spectrometry to measure glycation and structural differences. Results Elevated glucose inhibited S. aureus activation of C3 and deposition of C3b and iC3b on the bacterial surface. S. aureus-generated C5a and serum-mediated phagocytosis by neutrophils were both decreased in elevated glucose conditions. Interestingly, elevated glucose increased the binding of unactivated C3 to S. aureus, which was reversible on return to normal glucose concentrations. In a model of polymicrobial infection, S. aureus in elevated glucose conditions depleted C3 from serum resulting in decreased complement-mediated killing of E. coli. To investigate the effect of differing glucose concentration on C3 structure and glycation, purified C3 incubated with varying glucose concentrations was analyzed by mass spectrometry. Glycation was limited to the same three lysine residues in both euglycemic and hyperglycemic conditions over one hour, thus glycation could not account for observed changes between glucose conditions. However, surface labeling of C3 with sulfo-NHS-biotin showed significant changes in the surface availability of seven lysine residues in response to increasing glucose concentrations. These results suggest that the tertiary structure of C3 changes in response to hyperglycemic conditions leading to an altered interaction of C3 with bacterial pathogens. Conclusions These results demonstrate that hyperglycemic conditions inhibit C3-mediated complement effectors important in the immunological

  12. Effects of environmental stress on forest crown condition in Europe. Part I: hypotheses and approach to the study

    NARCIS (Netherlands)

    Vries, de W.; Klap, J.M.; Erisman, J.W.

    2000-01-01

    This paper is the first in a series of four, describing the hypothesis and approach of a correlative study between observed data on crown condition in Europe, monitored since 1986 at a systematic 16 x 16 km grid, and site-specific estimations of various natural and anthropogenic stress factors. The

  13. 33 CFR Appendix C to Part 273 - Information Requirements for Aquatic Plant Control Program Environmental Impact Statements

    Science.gov (United States)

    2010-07-01

    ... Aquatic Plant Control Program Environmental Impact Statements C Appendix C to Part 273 Navigation and... Environmental Impact Statements 1. Description of the problem. a. Pests. Identify the pest to be controlled by.... Relationship to environmental situation. Non-target organisms and integrated pest management programs. 2...

  14. Apparatus and method for non-invasive diagnosis and control of motor operated valve condition

    Science.gov (United States)

    Lyon, R.H.; Chai, J.; Lang, J.H.; Hagman, W.H.; Umans, S.D.; Saarela, O.J.

    1997-01-14

    An apparatus compares the torque from an MOV motor with the valve displacement, and from the comparison assesses MOV operating condition. A transducer measures the vibration of the housing of an MOV. The vibrations are due to the motions of the rotating elements within the housing, which motions are directly related to the motion of the valve relative to its seat. Signal processing apparatus analyzes the vibrations to recover the rotations of the rotating elements and thus the motion of the valve plug. Lost motion can also be determined (if a lost motion connection exists) by demodulating the vibration signal and thus taking into account also the lost motion. Simultaneously, the forces applied to the valve are estimated by estimating the torque between the stator and the rotor of the motor. Such torque can be estimated from measuring the input current and voltage alone, using a forgetting factor and a correction for the forgetting factor. A signature derived from relating the torque to the valve position can be used to assess the condition of the MOV, by comparing the signature to signatures for MOVs of known conditions. The vibration analysis components generate signals that relate to the position of elements in the operator. Similarly, the torque estimator estimates the torque output by any type of electric motor, whether or not part of an MOV analysis unit. 28 figs.

  15. Starch degradation in rumen fluid as influenced by genotype, climatic conditions and maturity stage of maize, grown under controlled conditions

    NARCIS (Netherlands)

    Ali, M.; Cone, J.W.; Hendriks, W.H.; Struik, P.C.

    2014-01-01

    Starch is the major component of maize kernels, contributing significantly to the feeding value of forage maize when fed to ruminants. The effects of genotype, climatic conditions and maturity stage on starch content in the kernels and on in vitro starch degradability in rumen fluid were

  16. Controlled growth of CNT in mesoporous AAO through optimized conditions for membrane preparation and CVD operation

    Energy Technology Data Exchange (ETDEWEB)

    Ciambelli, P; Sarno, M; Leone, C; Sannino, D [Department of Chemical and Food Engineering, University of Salerno, I-84084 Fisciano (Italy); Arurault, L; Fontorbes, S; Datas, L; Lenormand, P; Le Blond Du Plouy, S, E-mail: msarno@unisa.it, E-mail: arurault@chimie.ups-tlse.fr [Universite de Toulouse, CIRIMAT, UPS/INPT/CNRS, LCMIE, F-31062 Toulouse Cedex 9 (France)

    2011-07-01

    Anodic aluminium oxide (RAAO) membranes with a mesoporous structure were prepared under strictly controlling experimental process conditions, and physically and chemically characterized by a wide range of experimental techniques. Commercial anodic aluminium oxide (CAAO) membranes were also investigated for comparison. We demonstrated that RAAO membranes have lower content of both water and phosphorus and showed better porosity shape than CAAO. The RAAO membranes were used for template growth of carbon nanotubes (CNT) inside its pores by ethylene chemical vapour deposition (CVD) in the absence of a catalyst. A composite material, containing one nanotube for each channel, having the same length as the membrane thickness and an external diameter close to the diameter of the membrane holes, was obtained. Yield, selectivity and quality of CNTs in terms of diameter, length and arrangement (i.e. number of tubes for each channel) were optimized by investigating the effect of changing the experimental conditions for the CVD process. We showed that upon thermal treatment RAAO membranes were made up of crystallized allotropic alumina phases, which govern the subsequent CNT growth, because of their catalytic activity, likely due to their Lewis acidity. The strict control of experimental conditions for membrane preparation and CNT growth allowed us to enhance the carbon structural order, which is a critical requisite for CNT application as a substitute for copper in novel nano-interconnects.

  17. Statistical method for the control of the electric power service interruptions (second part); Metodo de control estadistico de las interrupciones del servicio electrico (2a. parte)

    Energy Technology Data Exchange (ETDEWEB)

    Issouribehere, Pedro E.; Barbero, Juan C. [Universidad Nacional de La Plata (UNLP), Buenos Aires (Argentina). Facultad de Ingenieria. Inst. de Investigaciones Tecnologicas para Redes y Equipos Electricos (IITREE-LAT)]. E-mail: iitree@.ing.unlp.edu.ar; Martinez, Jorge L.; Galinski, Alejandro [Ente Nacional Regulador de la Electricidad (ENRE), Buenos Aires (Argentina)

    2001-07-01

    This paper presents the register of interruptions in application points of the concession areas of three concessionaires. The reliability indexes are presented of the controlled sites: interruption ratio {lambda}, time of average reposition r and unavailability Q obtained with the field information recompiled during three years from June 2000. The paper also obtains by concessionaire, the ratios of brief interruptions occurrence which constitutes another indicator of the Electric Service Quality.

  18. Analysis of ex-vessel melt jet breakup and coolability. Part 1: Sensitivity on model parameters and accident conditions

    Energy Technology Data Exchange (ETDEWEB)

    Moriyama, Kiyofumi; Park, Hyun Sun, E-mail: hejsunny@postech.ac.kr; Hwang, Byoungcheol; Jung, Woo Hyun

    2016-06-15

    Highlights: • Application of JASMINE code to melt jet breakup and coolability in APR1400 condition. • Coolability indexes for quasi steady state breakup and cooling process. • Typical case in complete breakup/solidification, film boiling quench not reached. • Significant impact of water depth and melt jet size; weak impact of model parameters. - Abstract: The breakup of a melt jet falling in a water pool and the coolability of the melt particles produced by such jet breakup are important phenomena in terms of the mitigation of severe accident consequences in light water reactors, because the molten and relocated core material is the primary heat source that governs the accident progression. We applied a modified version of the fuel–coolant interaction simulation code, JASMINE, developed at Japan Atomic Energy Agency (JAEA) to a plant scale simulation of melt jet breakup and cooling assuming an ex-vessel condition in the APR1400, a Korean advanced pressurized water reactor. Also, we examined the sensitivity on seven model parameters and five initial/boundary condition variables. The results showed that the melt cooling performance of a 6 m deep water pool in the reactor cavity is enough for removing the initial melt enthalpy for solidification, for a melt jet of 0.2 m initial diameter. The impacts of the model parameters were relatively weak and that of some of the initial/boundary condition variables, namely the water depth and melt jet diameter, were very strong. The present model indicated that a significant fraction of the melt jet is not broken up and forms a continuous melt pool on the containment floor in cases with a large melt jet diameter, 0.5 m, or a shallow water pool depth, ≤3 m.

  19. Performance of various types of containment support under quasi-static and dynamic loading conditions, Part I.

    CSIR Research Space (South Africa)

    Kuijpers, JS

    2002-05-01

    Full Text Available deformations. In this project, the effects of dynamic loading are therefore specifically addressed. In order to monitor the effects of extreme dynamic loading conditions on various tunnel support systems, a real scale physical model has been used... systems and allow the identification of shortcomings and potential improvements. A conceptual, analytical model representing the load deformation behaviour of strings (lacing and mesh) has been developed. This model does allow for a quantification...

  20. Radiographic detection of initial carious lesions on the proximal surfaces of teeth. Part I. The influence of exposure conditions

    International Nuclear Information System (INIS)

    Arnold, L.V.

    1987-01-01

    The relationship between a number of technical exposure conditions and the diagnostic value of bitewing radiographs in the interpretation of initial proximal carious lesions was evaluated. The most important exposure factors for radiographs are tube voltage, filtration, and exposure time. Tube voltage and filtration were found to have an insignificant influence on the diagnostic quality. Exposure time proved to be the most critical factor in influencing diagnostic quality. The greatest difference in diagnostic quality, however, was caused by differences between observers

  1. Combined heat and gamma-irradiation treatments for the control of strawberry diseases under market conditions

    International Nuclear Information System (INIS)

    Brodrick, H.T.; Thomas, A.C.; Van Tonder, A.J.; Terblanche, J.C.

    1977-02-01

    The spoilage of strawberries under local market conditions was investigated. It was confirmed that the major losses are due to 'leak' disease caused by Rhizopus stolonifer (Ehr. ex Fr.) Lind. It was also established that further fruit losses in summer are due to anthracnose caused by the fungus Colletotrichum acutatum Simmonds. This is the first time that the latter pathogen has been isolated and identified and recognised as a problem on strawberries in South Africa. Studies with R. stolonifer in culture showed that 46 degrees Celsius for 20 min (the previous international standard heat treatment for fruit) was disappointing, while a treatment at 50 degrees Celsius for 10 min effectively inhibited spore germination. Irradiation studies with cultures of R. stolonifer and C. acutatum showed that a dose of 200 and 100 krad, respectively, resulted in excellent inhibition of spore germination. However, irradiating in nitrogen gas resulted in a tenfold reduction in the effectiveness of the irradiation treatments. The use of nitrogen during irradiation, therefore, cannot be considered, especially where an effective control of the fungal pathogens is desired. Investigations with different cultivars clearly demonstrated the synergistic effect on disease control obtained when combining heat and irradiation treatments. The combination treatment (moist heat at 50-52 degrees Celsius for 10 min plus 200 krad), besides effectively controlling both diseases in strawberries, did not adversely affect berry quality. In simulated transport tests it was shown that a minimal amount of berry softening did occur with this treatment, but this adverse effect was negligible compared with the beneficial effect obtained from disease control. In semi-commercial experiments it was shown that the combination heat and irradiation treatment effectively controlled spoilage diseases for a period of several days from picking, thus allowing sufficient time to market the fruit under local market

  2. Control Efficacy of Fungicides on Chinese Cabbage Clubroot under Several Conditions

    Directory of Open Access Journals (Sweden)

    Min-Yong Eom

    2011-08-01

    Full Text Available To develop the efficient screening methods for antifungal compound active to Chinese cabbage clubroot caused by Plasmodiophora brassicae, the control efficacy of three fungicides fluazinam, ethaboxam, and cyazofamid on the disease was tested under several conditions such as soil types, cultivars of Chinese cabbage, growth stages of the host, and inoculum concentrations. The in vivo antifungal activities of the fungicides on clubroot of two Chinese cabbage cultivars were hardly different. At 7- and 14-day-old seedlings, the fungicides were more effective to control of clubroot than at 21-day-old seedlings. In a commercial horticulture media soil (CNS, disease severity of untreated controls was higher and control activity of the fungicides was less than in a mixture of CNS and upland soil (1:1, v/v. Disease development of the seedlings inoculated with P. brassicae at 1.8×10(7 spores/pot to 1.1×10(9 spores/pot was almost same, but control efficacy of the fungicides was negatively correlated with inoculum dosages. To effectively select in vivo antifungal compound on Chinese cabbage clubroot, 14-day-old seedlings need to be inoculated with P. brassicae by drenching the spore suspension to give 1×10(8 spores/pot 1 day after chemical treatment. To develop clubroot, the inoculated plants are incubated in a growth chamber at 20℃ for 2 days, and then cultivated in a greenhouse (20±5℃ for four weeks.

  3. Experimental study on frosting control of mobile air conditioning system with microchannel evaporator

    International Nuclear Information System (INIS)

    Qu Xiaohua; Shi Junye; Qi Zhaogang; Chen Jiangping

    2011-01-01

    In this paper, a newly developed frost control system is proposed. System bench tests and vehicle test in wind tunnel have been carried out to explore the anti-frosting performance of automotive air conditioning system with microchannel evaporator. The experimental results are compared with the baseline conventional laminated evaporator system. The test results show that the installation position of temperature sensor can dramatically affect the anti-frosting performance. The clutch switching on/off temperature range of the microchannel evaporator is also experimentally studied. The test results show that, with a proper installation position and on/off temperature range, the system COP can be improved, and meanwhile the panel vents' air off temperature can be reduced, and temperature swing can be reduced. - Highlights: → The frost control systems were tested with microchannel and laminated evaporators separately. → The installation position of temperature sensor affects the anti-frosting performance. → Temperature control range affects the anti-frosting performance. → The panel vents' air off temperature and swing can be reduced by proper control parameters. → The system COP can be improved by proper control parameters.

  4. A Closed-Loop Control Strategy for Air Conditioning Loads to Participate in Demand Response

    Directory of Open Access Journals (Sweden)

    Xiaoqing Hu

    2015-08-01

    Full Text Available Thermostatically controlled loads (TCLs, such as air conditioners (ACs, are important demand response resources—they have a certain heat storage capacity. A change in the operating status of an air conditioner in a small range will not noticeably affect the users’ comfort level. Load control of TCLs is considered to be equivalent to a power plant of the same capacity in effect, and it can significantly reduce the system pressure to peak load shift. The thermodynamic model of air conditioning can be used to study the aggregate power of a number of ACs that respond to the step signal of a temperature set point. This paper analyzes the influence of the parameters of each AC in the group to the indoor temperature and the total load, and derives a simplified control model based on the two order linear time invariant transfer function. Then, the stability of the model and designs its Proportional-Integral-Differential (PID controller based on the particle swarm optimization (PSO algorithm is also studied. The case study presented in this paper simulates both scenarios of constant ambient temperature and changing ambient temperature to verify the proposed transfer function model and control strategy can closely track the reference peak load shifting curves. The study also demonstrates minimal changes in the indoor temperature and the users’ comfort level.

  5. Noble gas control room accident filtration system for severe accident conditions (N-CRAFT)

    International Nuclear Information System (INIS)

    Hill, Axel; Stiepani, Cristoph; Drechsler, Michael

    2015-01-01

    Severe accidents might cause the release of airborne radioactive substances to the environment of the NPP either due to containment leakages or due to intentional filtered containment venting. In the latter case aerosols and iodine are retained, however noble gases are not retainable by the FCVS or by conventional air filtration systems like HEPA filters and iodine absorbers. Radioactive noble gases nevertheless dominate the activity release depending on the venting procedure and the weather conditions. To prevent unacceptable contamination of the control room atmosphere by noble gases, AREVA GmbH has developed a noble gas control room accident filtration system (CRAFT) which can supply purified fresh air to the control room without time limitation. The retention process is based on dynamic adsorption of noble gases on activated carbon. The system consists of delay lines (carbon columns) which are operated by a continuous and simultaneous adsorption and desorption process. CRAFT allows minimization of the dose rate inside the control room and ensures low radiation exposure to the staff by maintaining the control room environment suitable for prolonged occupancy throughout the duration of the accident. CRAFT consists of a proven modular design either transportable or permanently installed. (author)

  6. Frequency effect on p-nitrophenol degradation under conditions of strict acoustic and electric control

    Directory of Open Access Journals (Sweden)

    Chang-ping Zhu

    2011-03-01

    Full Text Available The process of decomposing p-nitrophenol (PNP with power ultrasound requires strict control of acoustic and electric conditions. In this study, the conditions, including acoustic power and acoustic intensity, but not ultrasonic frequency, were controlled strictly at constant levels. The absorbency and the COD concentrations of the samples were measured in order to show the variation of the sample concentration. The results show significant differences in the trend of the solution degradation rate as acoustic power increases after the PNP solution (with a concentration of 114 mg/L and a pH value of 5.4 is irradiated for 60 min with ultrasonic frequencies of 530.8 kHz, 610.6 kHz, 855.0 kHz, and 1 130.0 kHz. The degradation rate of the solution increases with time and acoustic power (acoustic intensity. On the other hand, the degradation rate of the solution is distinctly dependent on frequency when the acoustic power and intensity are strictly controlled and maintained at constant levels. The degradation rate of the PNP solution declines with ultrasonic frequencies of 530.8 kHz, 610.6 kHz, 855.0 kHz, and 1 130.0 kHz; the COD concentration, on the contrary, increase.

  7. Birds achieve high robustness in uneven terrain through active control of landing conditions.

    Science.gov (United States)

    Birn-Jeffery, Aleksandra V; Daley, Monica A

    2012-06-15

    We understand little about how animals adjust locomotor behaviour to negotiate uneven terrain. The mechanical demands and constraints of such behaviours likely differ from uniform terrain locomotion. Here we investigated how common pheasants negotiate visible obstacles with heights from 10 to 50% of leg length. Our goal was to determine the neuro-mechanical strategies used to achieve robust stability, and address whether strategies vary with obstacle height. We found that control of landing conditions was crucial for minimising fluctuations in stance leg loading and work in uneven terrain. Variation in touchdown leg angle (θ(TD)) was correlated with the orientation of ground force during stance, and the angle between the leg and body velocity vector at touchdown (β(TD)) was correlated with net limb work. Pheasants actively targeted obstacles to control body velocity and leg posture at touchdown to achieve nearly steady dynamics on the obstacle step. In the approach step to an obstacle, the birds produced net positive limb work to launch themselves upward. On the obstacle, body dynamics were similar to uniform terrain. Pheasants also increased swing leg retraction velocity during obstacle negotiation, which we suggest is an active strategy to minimise fluctuations in peak force and leg posture in uneven terrain. Thus, pheasants appear to achieve robustly stable locomotion through a combination of path planning using visual feedback and active adjustment of leg swing dynamics to control landing conditions. We suggest that strategies for robust stability are context specific, depending on the quality of sensory feedback available, especially visual input.

  8. Determination of internal controls for quantitative gene expression of Isochrysis zhangjiangensis at nitrogen stress condition

    Science.gov (United States)

    Wu, Shuang; Zhou, Jiannan; Cao, Xupeng; Xue, Song

    2016-02-01

    Isochrysis zhangjiangensis is a potential marine microalga for biodiesel production, which accumulates lipid under nitrogen limitation conditions, but the mechanism on molecular level is veiled. Quantitative real-time polymerase chain reaction (qPCR) provides the possibility to investigate the gene expression levels, and a valid reference for data normalization is an essential prerequisite for firing up the analysis. In this study, five housekeeping genes, actin (ACT), α-tubulin (TUA), ß-tubulin (TUB), ubiquitin (UBI), 18S rRNA (18S) and one target gene, diacylglycerol acyltransferase (DGAT), were used for determining the reference. By analyzing the stabilities based on calculation of the stability index and on operating the two types of software, geNorm and bestkeeper, it showed that the reference genes widely used in higher plant and microalgae, such as UBI, TUA and 18S, were not the most stable ones in nitrogen-stressed I. zhangjiangensis, and thus are not suitable for exploring the mRNA expression levels under these experimental conditions. Our results show that ACT together with TUB is the most feasible internal control for investigating gene expression under nitrogen-stressed conditions. Our findings will contribute not only to future qPCR studies of I. zhangjiangensis, but also to verification of comparative transcriptomics studies of the microalgae under similar conditions.

  9. Complex dynamics and chaos control of duopoly Bertrand model in Chinese air-conditioning market

    International Nuclear Information System (INIS)

    Yi, Qi Guo; Zeng, Xiang Jin

    2015-01-01

    Highlights: •A dynamic duopoly Bertrand model with bounded rationality and quadratic cost function. •In Chinese air-conditioning market the boundary equilibrium point is locally stable. •The Lyapunov dimension of the chaos attractor is 1.9585. •The adjustment speeds may cause a market structure to behave chaotically. •The chaotic behavior can be controlled by decreasing the degree of substitutability. -- Abstract: A dynamic duopoly Bertrand model with quadratic cost function which is closer to reality and different from previous researches is discussed. The model is applied into air-conditioning market where the boundary equilibrium point is locally stable. Numerical simulations illustrate that the stability of Nash equilibrium strongly depends on the speed of adjustment of bounded rational player. The adjustment speeds and the degree of substitutability may undermine the stability of the equilibrium and cause a market structure to behave chaotically. The Lyapunov dimension of the chaos attractor is 1.9585 under some conditions. The stabilization of the chaotic behavior can be obtained by reducing the degree of substitutability. The results have an important theoretical and practical significance to Chinese air-conditioning market

  10. Control of first-wall surface conditions in the 2XIIB Magnetic Mirror Plasma Confinement experiment

    International Nuclear Information System (INIS)

    Simonen, T.C.; Bulmer, R.H.; Coensgen, F.H.

    1976-01-01

    The control of first-wall surface conditions in the 2XIIB Magnetic Mirror Plasma Confinement experiment is described. Before each plasma shot, the first wall is covered with a freshly gettered titanium surface. Up to 5 MW of neutral beam power has been injected into 2XIIB, resulting in first-wall bombardment fluxes of 10 17 atoms . cm -2 . s -1 of 13-keV mean energy deuterium atoms for several ms. The background gas flux is measured with a calibrated, 11-channel, fast-atom detector. Background gas levels are found to depend on surface conditions, injected beam current, and beam pulse duration. For our best operating conditions, an efective reflex coefficient of 0.3 can be inferred from the measurements. Experiments with long-duration and high-current beam injection are limited by charge exchange; however, experiments with shorter beam duration are not limited by first-wall surface conditions. It is concluded that surface effects will be reduced further with smoother walls. (Auth.)

  11. A critical spare part inventory control based on hazard function approach: A case study in a garment company

    Science.gov (United States)

    Melinda, Intan Dewi; Jauhari, Wakhid Ahmad

    2018-02-01

    Spare part procurement is a complex issue and requires an accurate analysis. Stock outs of spare part can leads a great impact on production. Therefore, it is necessary to design the inventory control of spare parts that guarantee the availability of spare parts needed for supporting the maintenance activity. This paper studies the inventory policy for sewing machine spare part using hazard function to approximate the demand. Hazard function is the indicator of the effect of ageing on the reliability of the system. It quantifies the risk of failure as the age of the system increases. We use a continuous review policy based on Hadley Within Approach to calculate the optimum inventory level for critical spare parts. There are four spare parts categorized as critical spare parts, which are needle plate, feed dog, rotary and binder attachment. The optimal ordering quantity for needle plate, feed, rotary and binder attachment are 5 units, 17 units, 5 units, and 9 units, respectively and the reorder point are 2 units, 1 unit, 2 units and 1 unit, respectively. Finally, the service level achieved by the proposed policy is in a range of 95.91%-97.93%, which indicates that the inventory level of spare parts can be used to support the required parts in the maintenance activity.

  12. Active tilting-pad journal bearings supporting flexible rotors: Part II–The model-based feedback-controlled lubrication

    DEFF Research Database (Denmark)

    Salazar, Jorge Andrés González; Santos, Ilmar

    2017-01-01

    This is part II of a twofold paper series dealing with the design and implementation of model-based controllers meant for assisting the hybrid and developing the feedback-controlled lubrication regimes in active tilting pad journal bearings (active TPJBs). In both papers theoretical and experimen...... derived in part I. Results show further suppression of resonant vibrations when using the feedback-controlled or active lubrication, overweighting the reduction already achieved with hybrid lubrication, thus improving the whole machine dynamic performance.......This is part II of a twofold paper series dealing with the design and implementation of model-based controllers meant for assisting the hybrid and developing the feedback-controlled lubrication regimes in active tilting pad journal bearings (active TPJBs). In both papers theoretical...... and experimental analyses are presented with focus on the reduction of rotor lateral vibration. This part is devoted to synthesising model-based LQG optimal controllers (LQR regulator + Kalman Filter) for the feedback-controlled lubrication and is based upon the mathematical model of the rotor-bearing system...

  13. Statement on the conditions of use for health claims related to meal replacements for weight control

    DEFF Research Database (Denmark)

    Sjödin, Anders Mikael

    2015-01-01

    ) and maintenance of body weight after weight loss (ID1418) pursuant to Article 13(1) of Regulation (EC) No 1924/2006. Taking into account that the mechanisms by which meal replacements could exert the claimed effects were mostly related to their controlled energy content and the relatively high protein/low fat...... content, the Panel concludes that the differences in the micronutrient composition of meal replacements which would derive from changing the conditions of use from Directive 96/8/EC to Regulation (EU) 1169/2011 do not affect the scientific substantiation of health claims related to meal replacements...

  14. Mixed models for data from thorough QT studies: part 2. One-step assessment of conditional QT prolongation.

    Science.gov (United States)

    Schall, Robert

    2011-01-01

    We investigate mixed analysis of covariance models for the 'one-step' assessment of conditional QT prolongation. Initially, we consider three different covariance structures for the data, where between-treatment covariance of repeated measures is modelled respectively through random effects, random coefficients, and through a combination of random effects and random coefficients. In all three of those models, an unstructured covariance pattern is used to model within-treatment covariance. In a fourth model, proposed earlier in the literature, between-treatment covariance is modelled through random coefficients but the residuals are assumed to be independent identically distributed (i.i.d.). Finally, we consider a mixed model with saturated covariance structure. We investigate the precision and robustness of those models by fitting them to a large group of real data sets from thorough QT studies. Our findings suggest: (i) Point estimates of treatment contrasts from all five models are similar. (ii) The random coefficients model with i.i.d. residuals is not robust; the model potentially leads to both under- and overestimation of standard errors of treatment contrasts and therefore cannot be recommended for the analysis of conditional QT prolongation. (iii) The combined random effects/random coefficients model does not always converge; in the cases where it converges, its precision is generally inferior to the other models considered. (iv) Both the random effects and the random coefficients model are robust. (v) The random effects, the random coefficients, and the saturated model have similar precision and all three models are suitable for the one-step assessment of conditional QT prolongation. Copyright © 2010 John Wiley & Sons, Ltd.

  15. Earth, Wind and Fire. Natural air conditioning. Part 2. Research results; Earth, Wind and Fire. Natuurlijke airconditioning. Deel 2. Onderzoeksresultaten

    Energy Technology Data Exchange (ETDEWEB)

    Bronsema, B. [Afdeling Architectural Engineering en Technology, Faculteit Bouwkunde, Technische Universiteit Delft TUD, Delft (Netherlands)

    2013-07-15

    The Earth, Wind and Fire concept transforms a building into a 'climate machine' which is powered by the natural forces and energy of the sun, wind, the mass of the earth and gravity. This second part provides a brief overview of the research. The full results are included in the thesis of the author [Dutch] Het Earth, Wind en Fire-concept voor natuurlijke airconditioning biedt meer zekerheid voor het realiseren van energieneutrale kantoorgebouwen dan mogelijk zou zijn door verbetering van bestaande technieken. Het concept maakt gebruik van de omgevingsenergie van aardmassa, wind en zon. In deel 1 worden de onderzoeksdoelen en -methoden van dit concept besproken. Dit deel 2 geeft een kort overzicht van de onderzoeksresultaten. De volledige resultaten van de basale en gedetailleerde modellen, de simulaties, de metingen in de fysieke modellen en het validatieproces zijn opgenomen in het proefschrift van de auteur.

  16. A survey on control schemes for distributed solar collector fields. Part I: Modeling and basic control approaches

    Energy Technology Data Exchange (ETDEWEB)

    Camacho, E.F.; Rubio, F.R. [Universidad de Sevilla, Escuela Superior de Ingenieros, Departamento de Ingenieria de Sistemas y Automatica, Camino de Los Descubrimientos s/n, E-41092, Sevilla (Spain); Berenguel, M. [Universidad de Almeria, Departamento de Lenguajes y Computacion, Area de Ingenieria de Sistemas y Automatica, Carretera Sacramento s/n, E-04120 La Canada, Almeria (Spain); Valenzuela, L. [Plataforma Solar de Almeria - CIEMAT, Carretera Senes s/n, P.O. Box 22, E-04200 Tabernas, Almeria (Spain)

    2007-10-15

    This article presents a survey of the different automatic control techniques that have been applied to control the outlet temperature of solar plants with distributed collectors during the last 25 years. Different aspects of the control problem involved in this kind of plants are treated, from modeling and simulation approaches to the different basic control schemes developed and successfully applied in real solar plants. A classification of the modeling and control approaches is used to explain the main features of each strategy. (author)

  17. Controlled production of Camembert-type cheeses. Part II. Changes in the concentration of the more volatile compounds.

    Science.gov (United States)

    Leclercq-Perlat, Marie-Noëlle; Latrille, Eric; Corrieu, Georges; Spinnler, Henry-Eric

    2004-08-01

    Flavour generation in cheese is a major aspect of ripening. In order to enhance aromatic qualities it is necessary to better understand the chemical and microbiological changes. Experimental Camembert-type cheeses were prepared in duplicate from pasteurized milk inoculated with Kluyveromyces lactis, Geotrichum candidum, Penicillium camemberti and Brevibacterium linens under aseptic conditions. Two replicates performed under controlled conditions of temperature (12 degrees C), relative humidity (95 +/- 2%), and atmosphere showed similar ripening characteristics. The evolutions of metabolite concentrations were studied during ripening. The volatile components were extracted by dynamic headspace extraction, separated and quantified by gas chromatography and identified by mass spectrometry. For each cheese the volatile concentrations varied with the part considered (rind or core). Except for ethyl acetate and 2-pentanone, the volatile quantities observed were higher than their perception thresholds. The flavour component production was best correlated with the starter strains. During the first 10 days the ester formations (ethyl, butyl and isoamyl acetates) were associated with the concentrations of K. lactis and G. candidum. The rind quantity of esters was lower than that observed in core probably due to (1) a diffusion from the core to the surface and (2) evaporation from the surface to the chamber atmosphere. G. candidum and Brev. linens association produced 3 methyl butanol and methyl 3-butanal from leucine, respectively. DMDS came from the methionine catabolism due to Brev. linens. Styrene production was attributed to Pen. camemberti. 2-Pentanone evolution was associated with Pen. camemberti spores and G. candidum. 2-Heptanone changes were not directly related to flora activities while 2-octanone production was essentially due to G. candidum. This study also demonstrates the determining role of volatile component diffusion.

  18. Autonomous tracked robots in planar off-road conditions modelling, localization, and motion control

    CERN Document Server

    González, Ramón; Guzmán, José Luis

    2014-01-01

    This monograph is framed within the context of off-road mobile robotics. In particular, it discusses issues related to modelling, localization, and motion control of tracked mobile robots working in planar slippery conditions. Tracked locomotion constitutes a well-known solution for mobile platforms operating over diverse challenging terrains, for that reason, tracked robotics constitutes an important research field with many applications (e.g. agriculture, mining, search and rescue operations, military activities). The specific topics of this monograph are: historical perspective of tracked vehicles and tracked robots; trajectory-tracking model taking into account slip effect; visual-odometry-based localization strategies; and advanced slip-compensation motion controllers ensuring efficient real-time execution. Physical experiments with a real tracked robot are presented showing the better performance of the suggested novel approaches to known techniques.   Keywords: longitudinal slip, visual odometry, slip...

  19. Controlled release of volatiles under mild reaction conditions: from nature to everyday products.

    Science.gov (United States)

    Herrmann, Andreas

    2007-01-01

    Volatile organic compounds serve in nature as semiochemicals for communication between species, and are often used as flavors and fragrances in our everyday life. The quite limited longevity of olfactive perception has led to the development of pro-perfumes or pro-fragrances--ideally nonvolatile and odorless fragrance precursors which release the active volatiles by bond cleavage. Only a limited amount of reaction conditions, such as hydrolysis, temperature changes, as well as the action of light, oxygen, enzymes, or microorganisms, can be used to liberate the many different chemical functionalities. This Review describes the controlled chemical release of fragrances and discusses additional challenges such as precursor stability during product storage as well as some aspects concerning toxicity and biodegradability. As the same systems can be applied in different areas of research, the scope of this Review covers fragrance delivery as well as the controlled release of volatiles in general.

  20. Control of root system architecture by DEEPER ROOTING 1 increases rice yield under drought conditions.

    Science.gov (United States)

    Uga, Yusaku; Sugimoto, Kazuhiko; Ogawa, Satoshi; Rane, Jagadish; Ishitani, Manabu; Hara, Naho; Kitomi, Yuka; Inukai, Yoshiaki; Ono, Kazuko; Kanno, Noriko; Inoue, Haruhiko; Takehisa, Hinako; Motoyama, Ritsuko; Nagamura, Yoshiaki; Wu, Jianzhong; Matsumoto, Takashi; Takai, Toshiyuki; Okuno, Kazutoshi; Yano, Masahiro

    2013-09-01

    The genetic improvement of drought resistance is essential for stable and adequate crop production in drought-prone areas. Here we demonstrate that alteration of root system architecture improves drought avoidance through the cloning and characterization of DEEPER ROOTING 1 (DRO1), a rice quantitative trait locus controlling root growth angle. DRO1 is negatively regulated by auxin and is involved in cell elongation in the root tip that causes asymmetric root growth and downward bending of the root in response to gravity. Higher expression of DRO1 increases the root growth angle, whereby roots grow in a more downward direction. Introducing DRO1 into a shallow-rooting rice cultivar by backcrossing enabled the resulting line to avoid drought by increasing deep rooting, which maintained high yield performance under drought conditions relative to the recipient cultivar. Our experiments suggest that control of root system architecture will contribute to drought avoidance in crops.

  1. Voltage controller design for air conditioning; Diseno de controlador de voltaje para aire acondicionado

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Andrade, R; Lopez Villalobos, J.J; Valderrama Chairez, J; Ramirez, R.L. [Instituto Tecnologico de Nuevo Leon, Guadalupe, Nuevo Leon (Mexico)]. E-mails: roxana_garciaandrade@yahoo.com; xe2n@yahoo.com.mx; jose.valderrama@ieee.org

    2013-03-15

    This paper discusses the design of a voltage controller for an air conditioning system in order to generate additional power in activation or startup of the system, for which as a first stage is presented the modeling power generation of electric current through alternative means, such as solar energy. The results of this study will be the basis for development of the physical prototype of this system controller. [Spanish] El presente trabajo trata sobre el diseno de un controlador de voltaje para un sistema de aire acondicionado con el fin de generar energia adicional en la activacion o arranque de dicho sistema, para lo cual como primer fase se presenta el modelado de la generacion de corriente electrica mediante medios alternos, como lo es la energia solar. Los resultados de este trabajo seran la base para desarrollo del prototipo fisico de este sistema controlador.

  2. Controlled synthesis of quantum confined CsPbBr3 perovskite nanocrystals under ambient conditions

    Science.gov (United States)

    He, Huimei; Tang, Bing; Ma, Ying

    2018-02-01

    Room temperature recrystallization is a simple and convenient method for synthesis of all-inorganic perovskite nanomaterials with excellent luminescent properties. However, the fast crystallization usually brings the colloidal stability and uncontrollable synthesis issues in the formation of all-inorganic perovskite. In the present study, we present a new strategy to prepare the quantum confined CsPbBr3 nanocrystals with controlled morphology under ambient condition. With the assist of fatty acid-capped precursor, the crystallization and the following growth rate can be retarded. Thanks to the retarded reaction, the morphology can be varied from nanowires to nanoplates and the thickness can be controlled from 5-7 monolayers by simply adjusting the amount of octylammonium cations and oleic acid. The nanoplates exhibit a higher photoluminescence quantum yield than the nanowires possibly due to fewer defects in the nanoplates.

  3. Controlled Synthesis of Quantum Confined CsPbBr3 perovskite Nanocrystals under Ambient Condition.

    Science.gov (United States)

    He, Huimei; Tang, Bing; Ma, Ying

    2017-11-21

    Room temperature recrystallization is a simple and convenient method for synthesis of all-inorganic perovskite nanomaterials with excellent luminescent properties. However, the fast crystallization usually brings the colloidal stability and uncontrollable synthesis issues in the formation of all-inorganic perovskite. In the present study, we present a new strategy to prepare the quantum confined CsPbBr3 nanocrystals with controlled morphology under ambient condition. With the assist of fatty acid-capped precursor, the crystallization and the following growth rate can be retarded. Thanks to the retarded reaction, the morphology can be varied from nanowires to nanoplates and the thickness can be controlled from 5 to 7 monolayers by simply adjusting the amount of octylammonium cations and oleic acid. The nanoplates exhibit a higher photoluminescence quantum yield than the nanowires possibly due to fewer defects in the nanoplates. © 2017 IOP Publishing Ltd.

  4. Existence conditions of optimal trajectories in dynamic control processes; Conditions d'existence de trajectoires optimales des processus dynamiques commandes

    Energy Technology Data Exchange (ETDEWEB)

    Bonnemay-Juricek, L. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    The existence of solutions in the optimal control problems with free endpoints is studied in this report and existence conditions are established without the usual assumption that the control region is convex. Furthermore the results, in order to be of some utility in physical applications, are expressed only by means of conditions on the parameters defining the system. (author) [French] Ce rapport etudie l'existence de solutions optimales dans les problemes de commande ou le point terminal est libre et ou la duree de l'evolution du systeme a optimiser est connue. Des conditions d'existence y sont formulees sans recourir a l'hypothese usuelle de convexite du domaine des valeurs des commandes. De plus on a cherche a rendre utilisables les resultats en ne faisant porter les conditions que sur les parametres directement accessibles du systeme. (auteur)

  5. Very high gravity ethanol fermentation by flocculating yeast under redox potential-controlled conditions

    Directory of Open Access Journals (Sweden)

    Liu Chen-Guang

    2012-08-01

    Full Text Available Abstract Background Very high gravity (VHG fermentation using medium in excess of 250 g/L sugars for more than 15% (v ethanol can save energy consumption, not only for ethanol distillation, but also for distillage treatment; however, stuck fermentation with prolonged fermentation time and more sugars unfermented is the biggest challenge. Controlling redox potential (ORP during VHG fermentation benefits biomass accumulation and improvement of yeast cell viability that is affected by osmotic pressure and ethanol inhibition, enhancing ethanol productivity and yield, the most important techno-economic aspect of fuel ethanol production. Results Batch fermentation was performed under different ORP conditions using the flocculating yeast and media containing glucose of 201 ± 3.1, 252 ± 2.9 and 298 ± 3.8 g/L. Compared with ethanol fermentation by non-flocculating yeast, different ORP profiles were observed with the flocculating yeast due to the morphological change associated with the flocculation of yeast cells. When ORP was controlled at −100 mV, ethanol fermentation with the high gravity (HG media containing glucose of 201 ± 3.1 and 252 ± 2.9 g/L was completed at 32 and 56 h, respectively, producing 93.0 ± 1.3 and 120.0 ± 1.8 g/L ethanol, correspondingly. In contrast, there were 24.0 ± 0.4 and 17.0 ± 0.3 g/L glucose remained unfermented without ORP control. As high as 131.0 ± 1.8 g/L ethanol was produced at 72 h when ORP was controlled at −150 mV for the VHG fermentation with medium containing 298 ± 3.8 g/L glucose, since yeast cell viability was improved more significantly. Conclusions No lag phase was observed during ethanol fermentation with the flocculating yeast, and the implementation of ORP control improved ethanol productivity and yield. When ORP was controlled at −150 mV, more reducing power was available for yeast cells to survive, which in turn improved their viability and VHG

  6. Controlled by Love: The Harmful Relational Consequences of Perceived Conditional Positive Regard.

    Science.gov (United States)

    Kanat-Maymon, Yaniv; Roth, Guy; Assor, Avi; Raizer, Abira

    2016-08-01

    Research on conditional positive regard (CPR) has shown that this seemingly benign practice has maladaptive correlates when used by parents. However, there is no research on the correlates of this practice in romantic relationships or on the processes mediating its effects. Building on self-determination theory (Deci & Ryan, ), three studies tested the hypothesis that perceived CPR impairs relationship quality, partly because it undermines the fulfillment of the basic psychological needs for autonomy and relatedness. Study 1 (N = 125) examined perceived CPR and relationship quality across four relationship targets: mother, father, romantic partner, and best friend. Study 2, involving romantic partners (N = 142), examined whether needs fulfillment mediated the association between perceived CPR and relationship quality. Study 3, involving romantic dyads (N = 85), also included partner reports on CPR. Across the three studies, CPR was linked with poor relationship quality between relationships, between people, and between dyadic partners. Moreover, results of Study 2 and Study 3 revealed that the inverse association between perceived CPR and relationship quality was mediated by dissatisfaction of autonomy but not relatedness. Despite its seemingly benign nature, CPR is detrimental to relationship quality, partly because it thwarts the basic need for autonomy. © 2015 Wiley Periodicals, Inc.

  7. Ash behavior during hydrothermal treatment for solid fuel applications. Part 2: Effects of treatment conditions on industrial waste biomass

    International Nuclear Information System (INIS)

    Mäkelä, Mikko; Yoshikawa, Kunio

    2016-01-01

    Highlights: • Effect of treatment conditions on composition and solubility of ash. • Ash dissolution and yield governed by liquid pH and calcium carbonate solubility. • Dissolution of calcium carbonate decreases ash fusion temperature during combustion. • Decreasing the ash content of sludge can weaken ash properties for combustion. - Abstract: This second half of our work on ash behavior concentrates on the effects of hydrothermal treatment conditions on paper sludge. Ash composition and solubility were determined based on treatment temperature, reactor solid load and liquid pH using experimental design and univariate regression methods. In addition, ash properties for combustion were evaluated based on recent developments on ash classification. Based on the results, all experimental variables had a statistically significant effect on ash yields. Only reactor solid load was statistically insignificant for char ash content, which increased based on increasing treatment temperature due to the decomposition of organic components. Ash dissolution and ash yield were governed by liquid pH and the generation of acids mainly due to the solubility of calcium carbonate identified as the main mineral species of paper sludge. Dissolution of calcium carbonate however decreased ash fusion temperatures more likely causing problems during char incineration. This indicated that decreasing the ash content of sludge during hydrothermal treatment can actually weaken ash properties for solid fuel applications.

  8. Forensic engineering of advanced polymeric materials. Part III - Biodegradation of thermoformed rigid PLA packaging under industrial composting conditions.

    Science.gov (United States)

    Musioł, Marta; Sikorska, Wanda; Adamus, Grazyna; Janeczek, Henryk; Richert, Jozef; Malinowski, Rafal; Jiang, Guozhan; Kowalczuk, Marek

    2016-06-01

    This paper presents a forensic engineering study on the biodegradation behaviour of prototype packaging thermoformed from PLA-extruded film and plain PLA film under industrial composting conditions. Hydrolytic degradation in water was conducted for reference. The effects of composting duration on changes in molar mass, glass transition temperature and degree of crystallinity of the polymeric material were monitored using gel permeation chromatography (GPC) and differential scanning calorimetry (DSC). The chemical structure of water soluble degradation products of the polymeric material was determined using nuclear magnetic resonance (NMR) and electrospray ionization mass spectrometry (ESI-MS). The results show that the biodegradation process is less dependent on the thermoforming process of PLA and more dependent on the composting/degradation conditions that are applied. The increase in the dispersity index, leading to the bimodal molar mass distribution profile, suggests an autocatalytic hydrolysis effect at the early stage of the composting process, during which the bulk hydrolysis mechanism dominantly operates. Both the prototype PLA-packaging and PLA rigid film samples were shown to have a gradual increase in opacity due to an increase in the degree of crystallinity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Relating Health Locus of Control to Health Care Use, Adherence, and Transition Readiness Among Youths With Chronic Conditions, North Carolina, 2015.

    Science.gov (United States)

    Nazareth, Meaghan; Richards, Jordan; Javalkar, Karina; Haberman, Cara; Zhong, Yi; Rak, Eniko; Jain, Nina; Ferris, Maria; van Tilburg, Miranda A L

    2016-07-21

    Health locus of control refers to the belief that health is in one's control (internal control) or is not in one's control (external control). Among adults, external locus of control is associated with negative health outcomes, whereas internal locus of control is associated with favorable outcomes. Few studies examined these associations among youths. The objective of our study was to determine how locus of control relates to health care use, medication adherence, missed school, and readiness for transition to adult medical care for youths with chronic conditions. Participants at a camp for youths aged 6 to 17 years with chronic health conditions completed a survey measuring locus of control, readiness for transition to adult care, and medication adherence. Their parents completed a separate part of the survey about health care use and missed school days in the past year. A total of 163 youths completed the survey (78.5% white; 52.1% female; mean age, 12.3 y). Internal locus of control (β = 0.196; P = .013) and external Doctor locus of control with doctors controlling disease (β = 0.181; P = .025) were positively associated with transition readiness. External control by chance or with others controlling disease was negatively associated with transition readiness (β = -0.248; P = .002) and positively associated with emergency department visits (β = 0.225; P = .004) and with number of hospital inpatient nights at hospital (β = 0.166; P = .04). Adolescents with external control of their health by chance or by other people are at increased risk for negative health outcomes and may fail to develop the self-management skills needed for successful transitioning to adult care. Future studies should examine effects of changes in locus of control on health outcomes among youths.

  10. Performance evaluation of control room HVAC and air cleaning systems under accident conditions

    International Nuclear Information System (INIS)

    Almerico, F.; Machiels, A.J.; Ornberg, S.C.; Lahti, G.P.

    1985-01-01

    In light water reactors, control rooms and technical support centers must be designed to provide habitable environments in accordance with the requirements specified in General Design Criterion 19 of Appendix A, 10 CFR Part 50. Therefore, the effectiveness of HVAC and air cleaning system designs with respect to plant operator protection has to be evaluated by the system designer. Guidance for performing the analysis has been previously given in ANSI/ASME N509-1980 as well as in presentations at past Air Cleaning Conferences. The previous work is extended and the methodology used in a generic, interactive computer program that performs Main Control Room and Technical Support Center (TSC) habitability analyses for LWR nuclear power plants is presented. For given accident concentrations of radionuclides or hazardous gases in the outdoor air intakes and plant spaces surrounding the Main Control Room (or TSC), the program models the performance of the HVAC and air cleaning system designs, and determines control room (or TSC) contaminant concentrations and plant operator protection factors. Calculated or actual duct leakage, air cleaning efficiency, and airborne contamination are taken into account. Flexibility of the model allows for the representation of most control rooms (or TSC) and associated HVAC and air cleaning system conceptual designs that have been used by the US architect/engineers. The program replaced tedious calculations to determine the effects of HVAC ductwork and equipment leakage and permits (1) parametric analyses of various HVAC system design options early in the conceptual phase of a project, and (2) analysis of the effects of leakage test results on contaminant room concentrations, and therefore operator doses

  11. Using a Novel Wireless-Networked Decentralized Control Scheme under Unpredictable Environmental Conditions.

    Science.gov (United States)

    Chang, Chung-Liang; Huang, Yi-Ming; Hong, Guo-Fong

    2015-11-12

    The direction of sunshine or the installation sites of environmental control facilities in the greenhouse result in different temperature and humidity levels in the various zones of the greenhouse, and thus, the production quality of crop is inconsistent. This study proposed a wireless-networked decentralized fuzzy control scheme to regulate the environmental parameters of various culture zones within a greenhouse. The proposed scheme can create different environmental conditions for cultivating different crops in various zones and achieve diversification or standardization of crop production. A star-type wireless sensor network is utilized to communicate with each sensing node, actuator node, and control node in various zones within the greenhouse. The fuzzy rule-based inference system is used to regulate the environmental parameters for temperature and humidity based on real-time data of plant growth response provided by a growth stage selector. The growth stage selector defines the control ranges of temperature and humidity of the various culture zones according to the leaf area of the plant, the number of leaves, and the cumulative amount of light. The experimental results show that the proposed scheme is stable and robust and provides basis for future greenhouse applications.

  12. Using a Novel Wireless-Networked Decentralized Control Scheme under Unpredictable Environmental Conditions

    Directory of Open Access Journals (Sweden)

    Chung-Liang Chang

    2015-11-01

    Full Text Available The direction of sunshine or the installation sites of environmental control facilities in the greenhouse result in different temperature and humidity levels in the various zones of the greenhouse, and thus, the production quality of crop is inconsistent. This study proposed a wireless-networked decentralized fuzzy control scheme to regulate the environmental parameters of various culture zones within a greenhouse. The proposed scheme can create different environmental conditions for cultivating different crops in various zones and achieve diversification or standardization of crop production. A star-type wireless sensor network is utilized to communicate with each sensing node, actuator node, and control node in various zones within the greenhouse. The fuzzy rule-based inference system is used to regulate the environmental parameters for temperature and humidity based on real-time data of plant growth response provided by a growth stage selector. The growth stage selector defines the control ranges of temperature and humidity of the various culture zones according to the leaf area of the plant, the number of leaves, and the cumulative amount of light. The experimental results show that the proposed scheme is stable and robust and provides basis for future greenhouse applications.

  13. Weed control and persistence of two oxyfluorfen formulations in olive groves under non tillage conditions.

    Science.gov (United States)

    Martínez, M J; Farsaoui, K; de Prado, R

    2004-01-01

    To obtain profitable yields in olive groves, residual preemergence herbicides are applied in October or November before the winter rains, and before the winter annual weeds germinate. Simazine, one of the herbicides most used for weed control in olive groves, has recently been banned. Oxyfluorfen is presented as a good alternative to simazine in olive fields. Experiments were carried out in 2002 and 2003 to evaluate the behaviour of two oxyfluorfen formulations, 2XL and G4F, at 480 g a.i. ha(-1) for three different soil management systems with three replications (1. bare soil; 2. bare soil and grassed buffer strips, chemically controlled and 3. bare soil and grassed buffer strips with controlled mowing; under non tillage conditions in all three cases). The most important species that survived 2XL and G4F treatments was Sagina apetala ARD. Oxyfluorfen residues were evaluated throughout 158 days after the applications. Three soil samples from each plot were collected, mixed and air dried. The herbicide extractions were made with methanol and the residues were analyzed by HPLC. We found no differences between the two formulations, but results showed that recoveries of oxyfluorfen were higher in plots with chemically controlled buffer grassed strips than in the other soil management types.

  14. H2 Control for the Continuous-Time Markovian Jump Linear Uncertain Systems with Partly Known Transition Rates and Input Quantization

    Directory of Open Access Journals (Sweden)

    Xin-Gang Zhao

    2013-01-01

    Full Text Available For a class of continuous-time Markovian jump linear uncertain systems with partly known transition rates and input quantization, the H2 state-feedback control design is considered. The elements in the transition rates matrix include completely known, boundary known, and completely unknown ones. First, an H2 cost index for Markovian jump linear uncertain systems is introduced; then by introducing a new matrix inequality condition, sufficient conditions are formulated in terms of linear matrix inequalities (LMIs for the H2 control of the Markovian jump linear uncertain systems. Less conservativeness is achieved than the result obtained with the existing technique. Finally, a numerical example is given to verify the validity of the theoretical results.

  15. The MEXICO project (Model Experiments in Controlled Conditions): The database and first results of data processing and interpretation

    International Nuclear Information System (INIS)

    Snel, H; Schepers, J G; Montgomerie, B

    2007-01-01

    The Mexico (Model experiments in Controlled Conditions) was a FP5 project, partly financed by European Commission. The main objective was to create a database of detailed aerodynamic and load measurements on a wind turbine model, in a large and high quality wind tunnel, to be used for model validation and improvement. Here model stands for both the extended BEM modelling used in state-of-the-art design and certification software, and CFD modelling of the rotor and near wake flow. For this purpose a three bladed 4.5 m diameter wind tunnel model was built and instrumented. The wind tunnel experiments were carried out in the open section (9.5*9.5 m 2 ) of the Large Scale Facility of the DNW (German-Netherlands) during a six day campaign in December 2006. The conditions for measurements cover three operational tip speed ratios, many blade pitch angles, three yaw misalignment angles and a small number of unsteady cases in the form of pitch ramps and rotor speed ramps. One of the most important feats of the measurement program was the flow field mapping, with stereo PIV techniques. Overall the measurement campaign was very successful. The paper describes the now existing database and discusses a number of highlights from early data processing and interpretation. It should be stressed that all results are first results, no tunnel correction has been performed so far, nor has the necessary checking of data quality

  16. Dissociative Part-Dependent Resting-State Activity in Dissociative Identity Disorder: A Controlled fMRI Perfusion Study

    OpenAIRE

    Schlumpf, Yolanda R.; Reinders, Antje A. T. S.; Nijenhuis, Ellert R. S.; Luechinger, Roger; van Osch, Matthias J. P.; Jäncke, Lutz

    2014-01-01

    Background: In accordance with the Theory of Structural Dissociation of the Personality (TSDP), studies of dissociative identity disorder (DID) have documented that two prototypical dissociative subsystems of the personality, the "Emotional Part'' (EP) and the "Apparently Normal Part'' (ANP), have different biopsychosocial reactions to supraliminal and subliminal trauma-related cues and that these reactions cannot be mimicked by fantasy prone healthy controls nor by actors. Methods: Arterial ...

  17. Fission products and nuclear fuel behaviour under severe accident conditions part 1: Main lessons learnt from the first VERDON test

    Science.gov (United States)

    Pontillon, Y.; Geiger, E.; Le Gall, C.; Bernard, S.; Gallais-During, A.; Malgouyres, P. P.; Hanus, E.; Ducros, G.

    2017-11-01

    This paper describes the first VERDON test performed at the end of September 2011 with special emphasis on the behaviour of fission products (FP) and actinides during the accidental sequence itself. Two other papers discuss in detail the post-test examination results (SEM, EPMA and SIMS) of the VERDON-1 sample. The first VERDON test was devoted to studying UO2 fuel behaviour and fission product releases under reducing conditions at very high temperature (∼2883 K), which was able to confirm the very good performance of the VERDON loop. The fuel sample did not lose its integrity during this test. According to the FP behaviour measured by the online gamma station (fuel sight), the general classification of the FP in relation to their released fraction is very accurate, and the burn-up effect on the release rate is clearly highlighted.

  18. Heat capacities of aqueous polar aromatic compounds over a wide range of conditions. Part I: phenol, cresols, aniline, and toluidines

    International Nuclear Information System (INIS)

    Censky, Miroslav; Hnedkovsky, Lubomir; Majer, Vladimir

    2005-01-01

    The heat capacities of dilute aqueous solutions of phenol (hydroxybenzene), three cresols (2-, 3- and 4-methylhydroxybenzene), aniline (aminobenzene) and three toluidines (2-, 3- and 4-methylaminobenzene) were determined using a modified flow Picker-type high temperature calorimeter. The measurements were performed at temperatures between (303 and 623) K or 573 K for compounds containing hydroxy or amino group, respectively, and at several pressures up to 30 MPa. Standard heat capacities (partial molar heat capacities at infinite dilution) obtained from the experimental data exhibit a strong increase with temperature above 500 K consistent with the evolution of the standard volumes reported earlier. The data for aqueous phenol were used for testing several semiempiric models proposed for description of the standard thermodynamic properties of aqueous solutes. Their ability to reproduce the temperature and pressure dependence of standard heat capacities and to extrapolate towards higher conditions were examined

  19. Statistical analysis of the geological-hydrological conditions within part of the Eye-Dashwa pluton, Atikokan, northwestern Ontario

    International Nuclear Information System (INIS)

    Brown, P.A.; Rey, N.A.C.

    1989-01-01

    The occurrence and distribution of fracture-filling material within the Eye-Dashwa granite indicate that the dominant fracture system formed shortly after emplacement and cooling of the pluton at 2678 ± 67 Ma. Subsequent reactivation of these ancient fractures was accompanied by sequentially younger and lower temperature filling materials. These reopened ancient fractures are best developed in the upper 300-400 m of the rock mass and are commonly conduits for present-day groundwater flow. Multiple linear regression analysis performed on the geological variables identified a highly significant correlation between a number of these variable and hydraulic conductivity values measured in 25 m test sections of the boreholes. The predictive capability of the regression design was tested with seven new test data and found to be a valid estimator of the hydrogeological conditions

  20. Analysis and characterization of security regions in power systems. Part I. Load flow feasibility conditions in power networks

    Energy Technology Data Exchange (ETDEWEB)

    Jarjis, J; Galiana, F D

    1980-03-01

    A set theoretic analysis of loadflow feasibility of a general power network with arbitrary PQ, PV and slack buses is presented. Load-flow feasibility is that property of a power network defining the theoretical limitations on the bus injections under which a steady state equilibrium exists. The set theoretic analysis is based on the study of the conical loadflow feasibility region. This region is characterised by a set of supporting hyperplanes each of which defines an explicit necessary condition for loadflow feasibility on the bus injections. A quantitative measure of loadflow feasibility for an arbitrary given operating injection vector is defined through a computable scalar stability margin. This stability margin permits the loadflow feasibility of different injections and network structures to be quantitatively compared and analysed.

  1. Performance simulation of the JPL solar-powered distiller. Part 1: Quasi-steady-state conditions. [for cooling microwave equipment

    Science.gov (United States)

    Yung, C. S.; Lansing, F. L.

    1983-01-01

    A 37.85 cu m (10,000 gallons) per year (nominal) passive solar powered water distillation system was installed and is operational in the Venus Deep Space Station. The system replaced an old, electrically powered water distiller. The distilled water produced with its high electrical resistivity is used to cool the sensitive microwave equipment. A detailed thermal model was developed to simulate the performance of the distiller and study its sensitivity under varying environment and load conditions. The quasi-steady state portion of the model is presented together with the formulas for heat and mass transfer coefficients used. Initial results indicated that a daily water evaporation efficiency of 30% can be achieved. A comparison made between a full day performance simulation and the actual field measurements gave good agreement between theory and experiment, which verified the model.

  2. Control of Variability in the Performance of Selective Laser Melting (SLM) Parts through Microstructure Control and Design

    Data.gov (United States)

    National Aeronautics and Space Administration — The high variability and low repeatability of metal parts produced using Additive Manufacturing (AM) represent a major barrier in getting AM into the mainstream....

  3. Design and transient analyses of passive emergency feedwater system of CPR1000. Part 1. Air cooling condition

    International Nuclear Information System (INIS)

    Zhang Yapei; Qiu Suizheng; Su Guanghui; Tian Wenxi; Cao Jianhua; Lu Donghua; Fu Xiangang

    2011-01-01

    The steam generator secondary passive emergency feedwater system is a new design for traditional generation Ⅱ + reactor CPR1000. The passive emergency feedwater system is designed to supply water to the SG shell side and improve the safety and reliability of CPR1000 by completely or partially replacing traditional emergency water cooling system in the event of the feed line break (FLB) or loss of heat sink accident. The passive emergency feedwater system consists of steam generator (SG), heat exchanger (HX), air cooling tower, emergency makeup tank (EMT), and corresponding pipes and valves for air cooling condition. In order to improve the safety and reliability of CPR1000, the model of the primary loop system and the passive emergency feedwater system was developed to investigate residual heat removal capability of the passive emergency feedwater system and the transient characteristics of the primary loop system affected by the passive emergency feedwater system using RELAP5/MOD3.4. The transient characteristics of the primary loop system and the passive emergency feedwater system were calculated in the event of feed line break accident. Sensitivity studies of the passive emergency feedwater system were also conducted to investigate the response of the primary loop and the passive emergency feedwater system on the main parameters of the passive emergency feedwater system. The passive emergency feedwater system could supply water to the SG shell side from the EMT successfully. The calculation results showed that the passive emergency feedwater system could take away the decay heat from the primary loop effectively for air cooling condition, and that the single-phase and two-phase natural circulations were established in the primary loop and passive emergency feedwater system loop, respectively. (author)

  4. Experimental study of the injection conditions influence over n-dodecane and diesel sprays with two ECN single-hole nozzles. Part II: Reactive atmosphere

    International Nuclear Information System (INIS)

    Payri, Raul; Salvador, F.J.; Gimeno, Jaime; Peraza, Jesús E.

    2016-01-01

    The second part of this experimental analysis, presented in this paper, seeks to go deep on the characterization of the Spray C and Spray D nozzles from the Engine Combustion Network, investigating the penetration of fuel spray at reacting conditions alongside characteristic parameters of combustion such as ignition delay and lift-off length. Both ECN mono-orifice injectors have similar nozzle flow capacity but different conicity degrees and corner sharpness, being Spray C more susceptible to cavitate. Schlieren imaging technique was employed to quantitatively measure reactive penetration and ignition delay, while lift-off length was identified through OH ∗ chemiluminescence. As in the inert part of this research, n-dodecane and commercial diesel were selected for the tests, thereby the effect of the fuel properties in the measured parameters was analyzed. Also, once again the concept of R-parameter, defined as the penetration derivative respect to the square root of time was calculated to delve into the penetration behavior. The experiments were performed in a constant pressure-flow facility able to reproduce engine-like thermodynamic conditions. Results revealed that R-parameter evolution can be divided in four stages: an inert zone, a ‘bump’, a ‘valley’ part and a quasi-steady one that overlaps the previous inert part. Those stages are highly governed by ambient temperature and oxygen concentration. Nozzle geometry and fuel properties demonstrated to have a noteworthy influence on all measured parameters.

  5. Conditionally controlling nuclear trafficking in yeast by chemical-induced protein dimerization.

    Science.gov (United States)

    Xu, Tao; Johnson, Cole A; Gestwicki, Jason E; Kumar, Anuj

    2010-11-01

    We present here a protocol to conditionally control the nuclear trafficking of target proteins in yeast. In this system, rapamycin is used to heterodimerize two chimeric proteins. One chimera consists of a FK506-binding protein (FKBP12) fused to a cellular 'address' (nuclear localization signal or nuclear export sequence). The second chimera consists of a target protein fused to a fluorescent protein and the FKBP12-rapamycin-binding (FRB) domain from FKBP-12-rapamycin associated protein 1 (FRAP1, also known as mTor). Rapamycin induces dimerization of the FKBP12- and FRB-containing chimeras; these interactions selectively place the target protein under control of the cell address, thereby directing the protein into or out of the nucleus. By chemical-induced dimerization, protein mislocalization is reversible and enables the identification of conditional loss-of-function and gain-of-function phenotypes, in contrast to other systems that require permanent modification of the targeted protein. Yeast strains for this analysis can be constructed in 1 week, and the technique allows protein mislocalization within 15 min after drug treatment.

  6. Periodic spring–mass running over uneven terrain through feedforward control of landing conditions

    International Nuclear Information System (INIS)

    III, Luther R Palmer; Eaton, Caitrin E

    2014-01-01

    This work pursues a feedforward control algorithm for high-speed legged locomotion over uneven terrain. Being able to rapidly negotiate uneven terrain without visual or a priori information about the terrain will allow legged systems to be used in time-critical applications and alongside fast-moving humans or vehicles. The algorithm is shown here implemented on a spring-loaded inverted pendulum model in simulation, and can be configured to approach fixed running height over uneven terrain or self-stable terrain following. Offline search identifies unique landing conditions that achieve a desired apex height with a constant stride period over varying ground levels. Because the time between the apex and touchdown events is directly related to ground height, the landing conditions can be computed in real time as continuous functions of this falling time. Enforcing a constant stride period reduces the need for inertial sensing of the apex event, which is nontrivial for physical systems, and allows for clocked feedfoward control of the swing leg. (paper)

  7. Periodic spring-mass running over uneven terrain through feedforward control of landing conditions.

    Science.gov (United States)

    Palmer, Luther R; Eaton, Caitrin E

    2014-09-01

    This work pursues a feedforward control algorithm for high-speed legged locomotion over uneven terrain. Being able to rapidly negotiate uneven terrain without visual or a priori information about the terrain will allow legged systems to be used in time-critical applications and alongside fast-moving humans or vehicles. The algorithm is shown here implemented on a spring-loaded inverted pendulum model in simulation, and can be configured to approach fixed running height over uneven terrain or self-stable terrain following. Offline search identifies unique landing conditions that achieve a desired apex height with a constant stride period over varying ground levels. Because the time between the apex and touchdown events is directly related to ground height, the landing conditions can be computed in real time as continuous functions of this falling time. Enforcing a constant stride period reduces the need for inertial sensing of the apex event, which is nontrivial for physical systems, and allows for clocked feedfoward control of the swing leg.

  8. Biodegradation Behaviour of Thermoplastic Starch Films Derived from Tacca leontopetaloides Starch under Controlled Composting Condition

    Science.gov (United States)

    Amin, A. M. Mohd; Sauid, S. Mohd; Hamid, K. H. Ku; Musa, M.

    2018-05-01

    The biodegradation study of thermoplastic starch (TPS) films derived from Tacca leontopetaloides starch; namely TPS/GLY, TPS/ACE and TPS/BCHR were investigated under controlled composting conditions. A manual set-up test rig in laboratory scale was built according to ISO 14855-1: 2012. The biodegradation percentage was determined by measuring the amount of CO2 evolved using titration method and validated by automatic system (Arduino UNO System) that detected the CO2 evolved. After 45 days under controlled composting condition, results indicated that TPS/GLY degraded the fastest, followed by TPS/BCHR and the TPS/ACE had the slowest degradation. The biodegradation process of TPS/GLY, TPS/ACE and TPS/BCHR also exhibited two stages with different degradation speeds. From these results, it indicated that chemical modification of the TPS films by adding acetic acid and rice husk bio-char to the thermoplastic starch can have a major impact on the biodegradation rate and final biodegradation percentage.

  9. 78 FR 76254 - Special Conditions: Airbus, Model A350-900 Series Airplane; Control Surface Awareness and Mode...

    Science.gov (United States)

    2013-12-17

    ...-0899; Notice No. 25-13-15-SC] Special Conditions: Airbus, Model A350-900 Series Airplane; Control... of proposed special conditions. SUMMARY: This action proposes special conditions for the Airbus Model..., data, or views. The most helpful comments reference a specific portion of the proposed special...

  10. Simplified model-based optimal control of VAV air-conditioning system

    Energy Technology Data Exchange (ETDEWEB)

    Nassif, N.; Kajl, S.; Sabourin, R. [Ecole de Technologie Superieure, Montreal, PQ (Canada). Dept. of Construction Engineering

    2005-07-01

    The improvement of Variable Air Volume (VAV) system performance is one of several attempts being made to minimize the high energy use associated with the operation of heating, ventilation and air conditioning (HVAC) systems. A Simplified Optimization Process (SOP) comprised of controller set point strategies and a simplified VAV model was presented in this paper. The aim of the SOP was to determine supply set points. The advantage of the SOP over previous methods was that it did not require a detailed VAV model and optimization program. In addition, the monitored data for representative local-loop control can be checked on-line, after which controller set points can be updated in order to ensure proper operation by opting for real situations with minimum energy use. The SOP was validated using existing monitoring data and a model of an existing VAV system. Energy use simulations were compared to that of the existing VAV system. At each simulation step, 3 controller set point values were proposed and studied using the VAV model in order to select a value for each point which corresponded to the best performance of the VAV system. Simplified VAV component models were presented. Strategies for controller set points were described, including zone air temperature, duct static pressure set points; chilled water supply set points and supply air temperature set points. Simplified optimization process calculations were presented. Results indicated that the SOP provided significant energy savings when applied to specific AHU systems. In a comparison with a Detailed Optimization Process (DOP), the SOP was capable of determining set points close to those obtained by the DOP. However, it was noted that the controller set points determined by the SOP need a certain amount of time to reach optimal values when outdoor conditions or thermal loads are significantly changed. It was suggested that this disadvantage could be overcome by the use of a dynamic incremental value, which

  11. Dynamic performance assessment of a residential building-integrated cogeneration system under different boundary conditions. Part II: Environmental and economic analyses

    International Nuclear Information System (INIS)

    Rosato, Antonio; Sibilio, Sergio; Scorpio, Michelangelo

    2014-01-01

    Highlights: • A building-integrated micro-cogeneration system was dynamically simulated. • Simulation data were analyzed from both environmental and economic point of views. • The proposed system was compared with a conventional supply system. • The proposed system reduces the environmental impact under heat-led operation. • The proposed system reduces the operating costs whatever the control logic is. - Abstract: This work examines the performance of a residential building-integrated micro-cogeneration system during the winter by means of a whole building simulation software. The cogeneration unit was coupled with a multi-family house composed of three floors, compliant with the transmittance values of both walls and windows suggested by the Italian Law; a stratified combined tank for both heating purposes and domestic hot water production was also used for storing heat. Simulations were performed considering the transient nature of the building and occupant driven loads as well as the part-load characteristics of the cogeneration unit. This system was described in detail and analyzed from an energy point of view in the companion paper. In this paper the simulation results were evaluated in terms of both carbon dioxide equivalent emissions and operating costs; detailed analyses were performed in order to estimate the influence of the most significant boundary conditions on both environmental and economic performance of the proposed system: in particular, three volumes of the hot water storage, four climatic zones corresponding to four Italian cities, two electric demand profiles, as well as two control strategies micro-cogeneration unit were considered. The assessment of environmental impact was performed by using the standard emission factors approach, neglecting the effects of local pollutants. The operating costs due to both natural gas and electric energy consumption were evaluated in detail, whereas both the capital and maintenance costs were

  12. Evaluating Models Of The Neutral, Barotropic Planetary Boundary Layer Using Integral Measures: Part Ii. Modelling Observed Conditions

    Science.gov (United States)

    Hess, G. D.; Garratt, J. R.

    The steady-state, horizontally homogeneous, neutral, barotropiccase forms the foundation of our theoretical understanding of the planetary boundary layer (PBL).While simple analytical models and first-order closure models simulate atmospheric observationsof this case well, more sophisticated models, in general, do not. In this paperwe examine how well three higher-order closure models, E - - l, E - l, and LRR - l,which have been especially modified for PBL applications, perform in predicting the behaviour of thecross-isobaric angle 0, the geostrophic drag coefficient Cg, and the integral of the dissipationrate over the boundary layer, as a function of the surface Rossby number Ro. For comparison we alsoexamine the performance of three first-order closure mixing-length models, two proposed byA. K. Blackadar and one by H. H. Lettau, and the performance of the standard model forsecond-order closure and a modification of it designed to reduce the overprediction of turbulence inthe upper part of the boundary layer.

  13. MPPT-Based Control Algorithm for PV System Using iteration-PSO under Irregular shadow Conditions

    Directory of Open Access Journals (Sweden)

    M. Abdulkadir

    2017-02-01

    Full Text Available The conventional maximum power point tracking (MPPT techniques can hardly track the global maximum power point (GMPP because the power-voltage characteristics of photovoltaic (PV exhibit multiple local peaks in irregular shadow, and therefore easily fall into the local maximum power point. These conditions make it very challenging, and to tackle this deficiency, an efficient Iteration Particle Swarm Optimization (IPSO has been developed to improve the quality of solution and convergence speed of the traditional PSO, so that it can effectively track the GMPP under irregular shadow conditions. This proposed technique has such advantages as simple structure, fast response and strong robustness, and convenient implementation. It is applied to MPPT control of PV system in irregular shadow to solve the problem of multi-peak optimization in partial shadow. In order to verify the rationality of the proposed algorithm, however, recently the dynamic MPPT performance under varying irradiance conditions has been given utmost attention to the PV society. As the European standard EN 50530 which defines the recommended varying irradiance profiles, was released lately, the corresponding researchers have been required to improve the dynamic MPPT performance. This paper tried to evaluate the dynamic MPPT performance using EN 50530 standard. The simulation results show that iterative-PSO method can fast track the global MPP, increase tracking speed and higher dynamic MPPT efficiency under EN 50530 than the conventional PSO.

  14. Performance Investigation of Air Velocity Effects on PV Modules under Controlled Conditions

    Directory of Open Access Journals (Sweden)

    Muzaffar Ali

    2017-01-01

    Full Text Available Junction temperature of PV modules is one of the key parameters on which the performance of PV modules depends. In the present work, an experimental investigation was carried out to analyze the effects of air velocity on the performance of two PV modules, that is, monocrystalline silicon and polycrystalline silicon under the controlled conditions of a wind tunnel in the presence of an artificial solar simulator. The parameters investigated include the surface temperature variation, power output, and efficiency of PV modules under varying air velocity from near zero (indoor lab. conditions to 15 m/s. Additionally, the results were also determined at two different module angular positions: at 0° angle, that is, parallel to air direction and at 10° angle with the direction of coming air to consider the effects of tilt angles. Afterwards, the thermal analysis of the modules was performed using Ansys-Fluent in which junction temperature and heat flux of modules were determined by applying appropriate boundary conditions, such as air velocity, heat flux, and solar radiation. Finally, the numerical results are compared with the experiment in terms of junction temperatures of modules and good agreement was found. Additionally, the results showed that the maximum module temperature drops by 17.2°C and the module efficiency and power output increased from 10 to 12% with increasing air velocity.

  15. Topographically-controlled site conditions drive vegetation pattern on inland dunes in Poland

    Science.gov (United States)

    Sewerniak, Piotr; Jankowski, Michał

    2017-07-01

    The inland dunes of Central Europe are commonly overplanted by Scots pine (Pinus sylvestris) monocultures in which the primary occurrence of the natural vegetation pattern is obliterated. We hypothesize that on naturally revegetated inland dunes the pattern is clear and driven by topographically-controlled site conditions. To test this hypothesis, we addressed the following research questions: (1) Does topography drive vegetation patterns on inland dunes and if so, what are main differences between vegetation in varying relief positions? (2) To what extent does topography involve the variability of microclimates and of soil properties, and how does the topographically-induced differentiation of these site conditions control vegetation patterns? We conducted interdisciplinary studies (applying floristic, pedological and microclimatic research techniques) on a naturally revegetated inland dune area situated on a military artillery training ground near Toruń, northern Poland. We investigated vegetation patterns with reference to three topographical position variants (north-facing slopes, south-facing slopes, and intra-dune depressions). We found distinct differences in vegetation characteristics covering the aforementioned topographical positions. This primarily concerned species composition of ground vegetation: Calluna vulgaris was dominant species on north-facing slopes, Corynephorus canescens on south-facing slopes, while Calamagrostis epigejos in intra-dune depressions. In comparison to dune slopes, the depressions were characterized by much higher biodiversity of vascular plant species. This followed the most favorable soil conditions for the existence of plants (higher moisture and nutrient pools) occurring in low topographical positions. However, tree succession was most advanced not in depressions, where the competitive impact of tall grasses on seedlings was recognized, but on north-facing slopes. Based on our results, we formulated some suggestions, which

  16. Conditions for settling liquid levels by means of gamma-ray relay control

    Energy Technology Data Exchange (ETDEWEB)

    Wakabayashi, N [Kobe Univ. (Japan). Faculty of Engineering

    1976-03-01

    Using a control action which consists of infusion and exhaust at constant speeds and a neutral zone to maintain liquid levels within a given range, a gamma-ray source, a detector, and two relays at the upper and lower limits of the counting rate were provided. The optimum condition in this case is discussed and confirmed experimentally. Since a counting rate-meter has a time constant and its output is subject to the statistical fluctuation, the liquid level may overrun the opposite limit, move again after settling within the range, or drift far out of the range by a load before actuation of the relay. Formulas are derived providing the conditions such that these phenomena will not occur more frequently than a tolerant probability. These give the relations between the counting rates at the upper and lower limits, the time constant of the rate-meter, the multipliers of the standard deviations of the counting rates, the infusing and exhausting speeds, and the hysteresis widths of the limiting relays. Since it can be said that the first two of the five quantities should be smaller and the next two greater, the optimum condition can be determined from the formulas. When the infusing and exhausting speeds are the same and the hysteresis widths are equal, the formulas show that the optimum is a case where the ratio of the counting rates at the two limits, which is taken smaller than unity, is small, and where each hysteresis width is equal to 0.34 times the difference between the two counting rates, almost regardless of the value of their ratio. The above-mentioned deductions were examined in a system constructed with a backscattered gamma-ray type level gauge and a controller for infusion and exhaust of water. Its results almost agreed with those of the deductions when the multipliers of the standard deviations are substituted for by 2.

  17. Additional cash incentive within a conditional cash transfer scheme: a 'controlled before and during' design evaluation study from India.

    Science.gov (United States)

    Lahariya, Chandrakant; Mishra, Ashok; Nandan, Deoki; Gautam, Praveen; Gupta, Sanjay

    2011-01-01

    Conditional Cash Transfer (CCT) schemes have shown largely favorable changes in the health seeking behavior. This evaluation study assesses the process and performance of an Additional Cash Incentive (ACI) scheme within an ongoing CCT scheme in India, and document lessons. A controlled before and during design study was conducted in Madhya Pradesh state of India, from August 2007 to March 2008, with increased in institutional deliveries as a primary outcome. In depth interviews, focus group discussions and household surveys were done for data collection. Lack of awareness about ACI scheme amongst general population and beneficiaries, cumbersome cash disbursement procedure, intricate eligibility criteria, extensive paper work, and insufficient focus on community involvement were the major implementation challenges. There were anecdotal reports of political interference and possible scope for corruption. At the end of implementation period, overall rate of institutional deliveries had increased in both target and control populations; however, the differences were not statistically significant. No cause and effect association could be proven by this study. Poor planning and coordination, and lack of public awareness about the scheme resulted in low utilization. Thus, proper IEC and training, detailed implementation plan, orientation training for implementer, sufficient budgetary allocation, and community participation should be an integral part for successful implementation of any such scheme. The lesson learned this evaluation study may be useful in any developing country setting and may be utilized for planning and implementation of any ACI scheme in future.

  18. Current physical activity improves balance control during sensory conflicting conditions in older adults.

    Science.gov (United States)

    Buatois, S; Gauchard, G C; Aubry, C; Benetos, A; Perrin, P

    2007-01-01

    Aging process is characterized by difficulties in ensuring balance control, especially in conditions of reduced or conflicting sensory information, leading to an increased risk of falling. Conversely, the practise of physical activities (PA) has been recognized as a good approach to improve the quality of balance control. This study aimed to investigate the influence of current and/or past PA on balance-related neurosensorial organization in older adults on the maintenance of the upright stance, especially during sensory conflicting situations. Postural control was evaluated by means of the Sensory Organization Test on 130 healthy noninstitutionalized volunteers aged over 65, split into four groups according to the presence or absence of PA before or after retirement. Subjects who practised PA for a long time (Gr1) and subjects who started PA after retirement (Gr2) displayed the best postural performances and better managed sensory conflicting situations compared to subjects who had stopped PA for many years (Gr3) and subjects who had never practised PA (Gr4). Multiple regression analyses revealed that current PA was the major determinant for postural parameters during sensorial conflict compared to age, gender, body mass index and past PA. Regular PA, even when started late in life, allows appropriate reorganization of the different components of postural control during sensory conflicting situations. Indeed, active subjects were more able to compensate for suppressed or perturbed sensory information by an increased usage of another referential and so to correct their posture by adopting a more appropriate balance strategy. Thus, PA counteracts the age-related decline of postural control and could consequently reduce the risk of falling.

  19. Veterinary homeopathy: systematic review of medical conditions studied by randomised trials controlled by other than placebo.

    Science.gov (United States)

    Mathie, Robert T; Clausen, Jürgen

    2015-09-15

    No systematic review has previously been carried out on randomised controlled trials (RCTs) of veterinary homeopathy in which the control group was an intervention other than placebo (OTP). For eligible peer-reviewed RCTs, the objectives of this study were to assess the risk of bias (RoB) and to quantify the effect size of homeopathic intervention compared with an active comparator or with no treatment. Our systematic review approach complied fully with the PRISMA 2009 Checklist. Cochrane methods were applied to assess RoB and to derive effect size using standard meta-analysis methods. Based on a thorough and systematic literature search, the following key attributes of the published research were distinguished: individualised homeopathy (n = 1 RCT)/non-individualised homeopathy (n = 19); treatment (n = 14)/prophylaxis (n = 6); active controls (n = 18)/untreated controls (n = 2). The trials were highly diverse, representing 12 different medical conditions in 6 different species. No trial had sufficiently low RoB to be judged as reliable evidence: 16 of the 20 RCTs had high RoB; the remaining four had uncertain RoB in several domains of assessment. For three trials with uncertain RoB and without overt vested interest, it was inconclusive whether homeopathy combined with conventional intervention was more or was less effective than conventional intervention alone for modulation of immune response in calves, or in the prophylaxis of cattle tick or of diarrhoea in piglets. Due to the poor reliability of their data, OTP-controlled trials do not currently provide useful insight into the effectiveness of homeopathy in animals.

  20. Exploring valid internal-control genes in Porphyra yezoensis (Bangiaceae) during stress response conditions

    Science.gov (United States)

    Wang, Wenlei; Wu, Xiaojie; Wang, Chao; Jia, Zhaojun; He, Linwen; Wei, Yifan; Niu, Jianfeng; Wang, Guangce

    2014-07-01

    To screen the stable expression genes related to the stress (strong light, dehydration and temperature shock) we applied Absolute real-time PCR technology to determine the transcription numbers of the selected test genes in P orphyra yezoensis, which has been regarded as a potential model species responding the stress conditions in the intertidal. Absolute real-time PCR technology was applied to determine the transcription numbers of the selected test genes in P orphyra yezoensis, which has been regarded as a potential model species in stress responding. According to the results of photosynthesis parameters, we observed that Y(II) and F v/ F m were significantly affected when stress was imposed on the thalli of P orphyra yezoensis, but underwent almost completely recovered under normal conditions, which were collected for the following experiments. Then three samples, which were treated with different grade stresses combined with salinity, irradiation and temperature, were collected. The transcription numbers of seven constitutive expression genes in above samples were determined after RNA extraction and cDNA synthesis. Finally, a general insight into the selection of internal control genes during stress response was obtained. We found that there were no obvious effects in terms of salinity stress (at salinity 90) on transcription of most genes used in the study. The 18S ribosomal RNA gene had the highest expression level, varying remarkably among different tested groups. RPS8 expression showed a high irregular variance between samples. GAPDH presented comparatively stable expression and could thus be selected as the internal control. EF-1α showed stable expression during the series of multiple-stress tests. Our research provided available references for the selection of internal control genes for transcripts determination of P. yezoensis.

  1. Relapse Prevention in Major Depressive Disorder: Mindfulness-Based Cognitive Therapy Versus an Active Control Condition

    Science.gov (United States)

    Shallcross, Amanda J.; Gross, James J.; Visvanathan, Pallavi D.; Kumar, Niketa; Palfrey, Amy; Ford, Brett Q.; Dimidjian, Sona; Shirk, Stephen; Holm-Denoma, Jill; Goode, Kari M.; Cox, Erica; Chaplin, William; Mauss, Iris B.

    2015-01-01

    Objective We evaluated the comparative effectiveness of Mindfulness-based cognitive therapy (MBCT) versus an active control condition (ACC) for depression relapse prevention, depressive symptom reduction, and improvement in life satisfaction. Method Ninety-two participants in remission from Major Depressive Disorder with residual depressive symptoms were randomized to either an 8-week MBCT or a validated ACC that is structurally equivalent to MBCT and controls for non-specific effects (e.g., interaction with a facilitator, perceived social support, treatment outcome expectations). Both interventions were delivered according to their published manuals. Results Intention-to-treat analyses indicated no differences between MBCT and ACC in depression relapse rates or time to relapse over a 60-week follow-up. Both groups experienced significant and equal reductions in depressive symptoms and improvements in life satisfaction. A significant quadratic interaction (group x time) indicated that the pattern of depressive symptom reduction differed between groups. The ACC experienced immediate symptom reduction post-intervention and then a gradual increase over the 60-week follow-up. The MBCT group experienced a gradual linear symptom reduction. The pattern for life satisfaction was identical but only marginally significant. Conclusions MBCT did not differ from an ACC on rates of depression relapse, symptom reduction, or life satisfaction, suggesting that MBCT is no more effective for preventing depression relapse and reducing depressive symptoms than the active components of the ACC. Differences in trajectory of depressive symptom improvement suggest that the intervention-specific skills acquired may be associated with differential rates of therapeutic benefit. This study demonstrates the importance of comparing psychotherapeutic interventions to active control conditions. PMID:26371618

  2. Responses to tonic heat pain in the ongoing EEG under conditions of controlled attention.

    Science.gov (United States)

    Giehl, Janet; Meyer-Brandis, Gesa; Kunz, Miriam; Lautenbacher, Stefan

    2014-03-01

    To confirm the existence of an ongoing electroencephalogram (EEG) pattern that is truly suggestive of pain, tonic heat pain was induced by small heat pulses at 1 °C above the pain threshold and compared to slightly less intense tonic non-painful heat pulses at 1 °C below the pain threshold. Twenty healthy subjects rated the sensation intensity during thermal stimulation. Possible confounding effects of attention were thoroughly controlled for by testing in four conditions: (1) focus of attention directed ipsilateral or (2) contralateral to the side of the stimulation, (3) control without a side preference, and (4) no control of attention at all. EEG was recorded via eight leads according to the 10/20 convention. Absolute power was computed for the frequency bands delta (0.5-4 Hz), theta (4-8 Hz), alpha1 (8-11 Hz), alpha2 (11-14 Hz), beta1 (14-25 Hz), and beta2 (25-35 Hz). Ratings were clearly distinct between the heat and pain conditions and suggestive for heat and pain sensations. Manipulation of attention proved to be successful by producing effects on the ratings and on the EEG activity (with lower ratings and lower EEG activity (theta, beta1, 2) over central areas for side-focused attention). During pain stimulation, lower central alpha1 and alpha2 activity and higher right-parietal and right-occipital delta power were observed compared to heat stimulation. This EEG pattern was not influenced by the manipulation of attention. Since the two types of stimuli (pain, heat) were subjectively felt differently although stimulation intensities were nearby, we conclude that this EEG pattern is clearly suggestive of pain.

  3. Development of high-density bentonite barriers by means of spraying methods. Part 2. Investigation of field conditions

    International Nuclear Information System (INIS)

    Tanaka, Toshiyuki; Kobayashi, Ichizo; Nakajima, Makoto; Toida, Masaru

    2006-01-01

    The authors have developed a method of constructing high-density bentonite by means of wet spraying to act as a backfill material in narrow places in radioactive waste disposal facilities. On the basis of the results of laboratory tests, they conducted field spraying tests to investigate the field conditions. The results of these tests are summarized as follows: 1) The bentonite could be sprayed smoothly by using a rotary spraying machine and a screw conveyor. 2) Provided that the air flow was at least 18.5 m 3 /min and the nozzle diameter did not exceed 25 mm, an average dry density of bentonite of 1.6 Mg/m 3 or higher could be achieved. 3) The dry density was constant within the spraying distance range 500 mm ∼ 2000 mm. 4) With a nozzle diameter of 19 mm, a spraying distance of 1000 mm, and a water content of 19.5%, an average dry density of the sprayed bentonite of 1.6 Mg/m 3 or higher and a rebound ratio not exceeding 30% was achieved. 5) The dry density of the sprayed bentonite decreased as the volume of bentonite supplied was increased, and it was shows to be closely related to the rotational speed of the spraying machine and the volume of bentonite sprayed from each hole. (author)

  4. Microbial ecology of Rum Jungle, III. Leaching behaviour of sulphidic waste material under controlled conditions

    International Nuclear Information System (INIS)

    Babij, T.; Goodman, A.; Khalid, A.M.; Ralph, B.J.

    1981-12-01

    The discharge, into river systems, of acid and heavy metals generated by leaching of sulphidic waste materials at the abandoned opencut uranium mine at Rum Jungle, Northern Territory, is causing continuing pollution of the surrounding environment. The maximum effects of acid and microorganisms on samples from the overburden dump material, under defined and controlled environmental conditions, were assessed using reactor systems. These samples came from the overburden dump resulting from the mining of White's orebody. Similarly, the stability of tailings material under conditions of flooding and increasing acidity was determined. At ph 2.5, metals in White's dump material were solubilised by acid attack only, whereas at pH 3.5, bacterial activity (principally that of Thiobacillus ferrooxidans) generated acidity and contributed significantly to metal release. Under microaerophilic conditions Thiobacillus ferrooxidans continued to effect metal release from the ore, but did not produce further acidity. If White's overburden is returned to the acidic, flooded opencuts, complete solubilisation of the material will occur. The exclusion of oxygen from the dump will not necessarily stop bacterially catalysed leaching processes. Under highly aerated and agitated flooded conditions the tailings material was not active, except for copper release of about 2 g kg -1 ore at pH 4.0. The only deleterious element released by increasing acidity was copper, which was 100 per cent solubilised at pH 2.5. Uranium was always lss than 3 μg kg -1 ore, and lead was detected only at pH 2.5. Indigenous leaching bacteria did not develop

  5. Internal control as part of prevention irregularities in accounting of budgetary institution

    OpenAIRE

    O.М. Bunda; E.М. Guzenko

    2016-01-01

    The article researches the principles of internal control, the importance, the rationale for the essence of the system of internal control and the legislative building in budgetary institution. It describes the main challenges and problems of practical application of internal control in the normal course of business in modern enterprises. It reveals the following elements of the internal control of a budget institution as: control environment, risk assessment process of a budget institu...

  6. Electronic apex locator: A comprehensive literature review — Part II: Effect of different clinical and technical conditions on electronic apex locator′s accuracy

    Directory of Open Access Journals (Sweden)

    Hamid Razavian

    2014-01-01

    Full Text Available Introduction: To investigate the effects of different clinical and technical conditions on the accuracy of electronic apex locators (EALs. Materials and Methods: "Tooth apex," "dental instrument," "odontometry," "electronic medical," and "electronic apex locator" were searched as primary identifiers via Medline/PubMed, Cochrane library, and Scopus data base up to 30 July 2013. Original articles that fulfilled the inclusion criteria were selected and reviewed. Results: Out of 402 relevant studies, 183 were selected based on the inclusion criteria. In this part, 75 studies are presented. Pulp vitality conditions and root resorption, types of files and irrigating materials do not affect an EAL′s accuracy; however, the file size and foramen diameter can affect its accuracy. Conclusions: Various clinical conditions such as the file size and foramen diameter may affect EALs′ accuracy. However, more randomized clinical trials are needed for definitive conclusion.

  7. Structured functional assessments in general practice increased the use of part-time sick leave: a cluster randomised controlled trial.

    Science.gov (United States)

    Osterås, Nina; Gulbrandsen, Pål; Kann, Inger Cathrine; Brage, Søren

    2010-03-01

    A method for structured functional assessments of persons with long-term sick leave was implemented in a cluster randomised controlled trial in general practice. The aim was to analyse intervention effects on general practitioner (GP) sick-listing practice and patient sick leave. 57 GPs were randomly assigned to an intervention or a control group. The intervention group GPs learned the method at a 1-day workshop including teamwork and role-playing. The control group GPs were requested to assess functional ability as usual during the 8 months intervention period in 2005. Outcome measures included duration of patient sick leave episodes, GP prescription of part-time sick leave, active sick leave, and vocational rehabilitation. This data was extracted from a national register. The GPs in the intervention group prescribed part-time sick leave more often (p part-time and less active sick leave compared to the control group GPs. As a result, more intervention GP patients returned to part-time work compared to control GP patients. No intervention effect was seen on duration of patient sick leave episodes or on prescription of vocational rehabilitation.

  8. Control Strategy of Three-Phase Photovoltaic Inverter under Low-Voltage Ride-Through Condition

    Directory of Open Access Journals (Sweden)

    Xianbo Wang

    2015-01-01

    Full Text Available The new energy promoting community has recently witnessed a surge of developments in photovoltaic power generation technologies. To fulfill the grid code requirement of photovoltaic inverter under low-voltage ride-through (LVRT condition, by utilizing the asymmetry feature of grid voltage, this paper aims to control both restraining negative sequence current and reactive power fluctuation on grid side to maintain balanced output of inverter. Two mathematical inverter models of grid-connected inverter containing LCL grid-side filter under both symmetrical and asymmetric grid are proposed. PR controller method is put forward based on inverter model under asymmetric grid. To ensure the stable operation of the inverter, grid voltage feedforward method is introduced to restrain current shock at the moment of voltage drop. Stable grid-connected operation and LVRT ability at grid drop have been achieved via a combination of rapid positive and negative sequence component extraction of accurate grid voltage synchronizing signals. Simulation and experimental results have verified the superior effectiveness of our proposed control strategy.

  9. Analysis of the Impact of Urban Microclimate on Air Conditioning Load Control

    Directory of Open Access Journals (Sweden)

    Hu Xiaoqing

    2016-01-01

    Full Text Available Due to the presence of urban heat island effect (UHIE, high humidity and other urban microclimate, temperature of city central area rises. This causes that the actual air-conditioning energy consumption (ACEC in the urban central area is much higher than that in the suburbs. Load control of air-conditioners (ACs is considered to be equivalent to a power plant of the same capacity, and it can greatly reduce the system pressure to peak load shift. In this paper, a simplified second order transfer function control model of ACs is presented, and its parameters will be influenced by the ambient temperature and urban microclimate. The temperature is obtained by using the temperature inversion algorithm of the heat island effect. Then, the heat index is calculated by combining temperature and humidity. The ambient temperature index of urban central area is modified based on the above microclimate, and the second order linear time invariant model of aggregated ACs is upgraded to the linear time varying model. Furthermore, the consequent parameter changes of the second order transfer function model are studied and the influence of urban microclimate on AC load control is analyzed. The proposed method is verified on numerical examples

  10. Quality controls for wind measurement of a 1290-MHz boundary layer profiler under strong wind conditions.

    Science.gov (United States)

    Liu, Zhao; Zheng, Chaorong; Wu, Yue

    2017-09-01

    Wind profilers have been widely adopted to observe the wind field information in the atmosphere for different purposes. But accuracy of its observation has limitations due to various noises or disturbances and hence need to be further improved. In this paper, the data measured under strong wind conditions, using a 1290-MHz boundary layer profiler (BLP), are quality controlled via a composite quality control (QC) procedure proposed by the authors. Then, through the comparison with the data measured by radiosonde flights (balloon observations), the critical thresholds in the composite QC procedure, including consensus average threshold T 1 and vertical shear threshold T 3 , are systematically discussed. And the performance of the BLP operated under precipitation is also evaluated. It is found that to ensure the high accuracy and high data collectable rate, the optimal range of subsets is determined to be 4 m/s. Although the number of data rejected by the combined algorithm of vertical shear examination and small median test is quite limited, it is proved that the algorithm is quite useful to recognize the outlier with a large discrepancy. And the optimal wind shear threshold T 3 can be recommended as 5 ms -1 /100m. During patchy precipitation, the quality of data measured by the four oblique beams (using the DBS measuring technique) can still be ensured. After the BLP data are quality controlled by the composite QC procedure, the output can show good agreement with the balloon observation.

  11. Full- and part-time work: gender and welfare-type differences in European working conditions, job satisfaction, health status, and psychosocial issues.

    Science.gov (United States)

    Bartoll, Xavier; Cortès, Imma; Artazcoz, Lucía

    2014-07-01

    The aim of this study was to analyze the differences between full- and part-time employment (FTE and PTE) in terms of working conditions, on the one hand, and job satisfaction, health status, and work-related psychosocial problems according to gender and welfare state regime, on the other hand, and to analyze the role of working conditions in the association between PTE and FTE. This cross-sectional study was based on a sample of 7921 men and 8220 women from the European Working Conditions Survey aged 16-64 years, who were employed part-time (5-19 or 20-30 hours per week) or full-time (31-40 hours/week). Multiple logistic regression models were fitted separately for each gender and welfare state regime. PTE is associated with poorer working conditions than FTE for all national welfare types. Among women, only those in southern European countries experienced low job satisfaction [odds ratio after adjustment (OR adj) for sociodemographic variables, OR adj1.73, and 1.66, for those working 20-30 and 5-19 hours/week, respectively; reference group: FTE workers], but this association disappeared after further adjustment for working conditions. Low job satisfaction and poorer health status was more common among PTE men from continental (low job satisfaction, OR adj1.80 and 3.61, for 20-30 and 5-19 working hours/week, respectively), and southern European (OR adj, 2.98, for 5-19 working hours/week) countries. PTE tended to be associated with fewer psychosocial problems among women, but with more psychosocial problems among men in continental Europe and those those engaged in "mini-jobs" in southern European welfare regimes. The association between FTE and PTE and job satisfaction, health status, and psychosocial problems is partly driven by working conditions and differs between gender and welfare regime. This highlights the importance of promoting effective measures to ensure equal treatment between FTE and PTE workers and the role of the social norms that form part of

  12. Tests of a sodium bonded type control element of 'Monju' with the actual conditions. Pt. 1

    International Nuclear Information System (INIS)

    Katoh, Jungo; Tanaka, Masako; Ikarimoto, Iwao

    2004-03-01

    This report provides a summary of the following three experimental and analytical results conducted on the sodium bonded double porous-plug type control element: the pretest of retention of the absorber in the double C-type shroud tube (the ASMI test); the stress analysis of the double C-type shroud tube; and the long-term submersion test of the sodium bonded type control element. The objective of the ASMI test and the stress analysis is to define the shroud tube's bottom structure. First, simulating the absorber shroud mechanical interaction (ASMI), we checked the function of absorber holding of the double C-type shroud tube. Second, we conducted the stress analysis, changing the distance between the end plug of the tube and the bottom end of the absorber, to determine proper position of the absorber. In addition, we conducted the long-term submersion test of the control element on which sodium residues had been left, and confirmed that no trouble occurred even though the element was submerged for a long time. The results of the above tests and analysis are as follows: (1) On the conditions that the end plug of the shroud tube was fitted from outside of the double C-type shroud tube was double-layered, we checked through the ASMI test that no absorber leaked and the holding property was secured even though the absorber be powdery. (2) The stress analysis showed that the structural integrity was satisfied when the distance between the end plug of the tube and the bottom end of the absorber was 40 mm or longer, and that the stress in the shroud tube was within the elastic range when the distance was 50 mm or longer. From these results, we could assure the structure integrity of 50 mm distance case. (3) The result of the long-term submersion test showed that no trouble occurred when the sodium bonded type control rod assembly (control element) is stored under water with sodium residues after cleaning in the sodium cleansing facility, the temperature increase and the

  13. High-definition infrared thermography of ice nucleation and propagation in wheat under natural frost conditions and controlled freezing.

    Science.gov (United States)

    Livingston, David P; Tuong, Tan D; Murphy, J Paul; Gusta, Lawrence V; Willick, Ian; Wisniewski, Micheal E

    2018-04-01

    An extremely high resolution infrared camera demonstrated various freezing events in wheat under natural conditions. Many of those events shed light on years of misunderstanding regarding freezing in small grains. Infrared thermography has enhanced our knowledge of ice nucleation and propagation in plants through visualization of the freezing process. The majority of infrared analyses have been conducted under controlled conditions and often on individual organs instead of whole plants. In the present study, high-definition (1280 × 720 pixel resolution) infrared thermography was used under natural conditions to visualize the freezing process of wheat plants during freezing events in 2016 and 2017. Plants within plots were found to freeze one at a time throughout the night and in an apparently random manner. Leaves on each plant also froze one at a time in an age-dependent pattern with oldest leaves freezing first. Contrary to a common assumption that freezing begins in the upper parts of leaves; freezing began at the base of the plant and spread upwards. The high resolution camera used was able to verify that a two stage sequence of freezing began within vascular bundles. Neither of the two stages was lethal to leaves, but a third stage was demonstrated at colder temperatures that was lethal and was likely a result of dehydration stress; this stage of freezing was not detectable by infrared. These results underscore the complexity of the freezing process in small grains and indicate that comprehensive observational studies are essential to identifying and selecting freezing tolerance traits in grain crops.

  14. A Randomized Controlled Trial of Intensive Sleep Retraining (ISR): A Brief Conditioning Treatment for Chronic Insomnia

    Science.gov (United States)

    Harris, Jodie; Lack, Leon; Kemp, Kristyn; Wright, Helen; Bootzin, Richard

    2012-01-01

    Study Objective: To investigate the effectiveness of intensive sleep retraining in comparison and combination with traditional behavioral intervention for chronic primary insomnia. Participants: Seventy-nine volunteers with chronic sleep-onset insomnia (with or without sleep maintenance difficulties) were randomly assigned either to intensive sleep retraining (ISR), stimulus control therapy (SCT), ISR plus SCT, or the control (sleep hygiene) treatment condition. Intervention: ISR treatment consisted of 50 sleep onset trials over a 25-h sleep deprivation period. Measurements and Results: Treatment response was assessed with sleep diary, activity monitoring, and questionnaire measures. The active treatment groups (ISR, SCT, ISR+SCT) all resulted in significant improvements in sleep onset latency and sleep efficiency, with moderate to large effect sizes from pre- to post-treatment. Wake time after sleep onset decreased significantly in the SCT and ISR+SCT groups. Total sleep time increased significantly in the ISR and ISR+SCT treatment groups. Participants receiving ISR (ISR, ISR+SCT) experienced rapidly improved SOL and TST during treatment, suggesting an advantage of rapid improvements in sleep in response to ISR. Although there were few statistically significant differences between groups on individual variables, ISR+SCT resulted in consistently larger effect sizes of change than other treatments, including questionnaire measures of sleep quality, sleep self-efficacy, and daytime functioning. The combination treatment group (ISR+SCT) showed trends to outperform other active treatment groups with fewer treatment dropouts, and a greater proportion of treatment responders with 61% reaching “good sleeper” status. Treatment gains achieved at post-treatment in the active treatment groups were largely maintained throughout follow-up periods to 6 months. Conclusion: This 25-hour intensive conditioning treatment for chronic insomnia can produce rapid improvements in

  15. General collaboration offer of Johnson Controls regarding the performance of air conditioning automatic control systems and other buildings` automatic control systems

    Energy Technology Data Exchange (ETDEWEB)

    Gniazdowski, J.

    1995-12-31

    JOHNSON CONTROLS manufactures measuring and control equipment (800 types) and is as well a {open_quotes}turn-key{close_quotes} supplier of complete automatic controls systems for heating, air conditioning, ventilation and refrigerating engineering branches. The Company also supplies Buildings` Computer-Based Supervision and Monitoring Systems that may be applied in both small and large structures. Since 1990 the company has been performing full-range trade and contracting activities on the Polish market. We have our own well-trained technical staff and we collaborate with a series of designing and contracting enterprises that enable us to have our projects carried out all over Poland. The prices of our supplies and services correspond with the level of the Polish market.

  16. Evaluation of main control room habitability in Japanese LWR (1). Outline of evaluation method and conditions

    International Nuclear Information System (INIS)

    Fujita, Yuko; Yoneda, Jiro; Okabayashi, Kazuki; Fukuda, Ryo

    2009-01-01

    It has been recognized that main control room habitability (CRH) is very important safety item. Its evaluation method and conditions was recently updated as a common method both for Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) in Japan. This paper describes the common procedure for CRH evaluation. Postulated accidents for CRH evaluation are Loss of Coolant Accident (LOCA) for BWR and PWR, Main Steam Line Break Accident(MSLBA) for BWR, and Steam Generator Tube Rupture(SGTR) for PWR. Evaluation period is thirty days after each accident occurs. Acceptable criterion for each operator is 100mSv as total effective dose equivalent for thirty days, considering the net staying period of an operator in a control room and frequency of alternation of working staff. Total effective dose equivalent is calculated not only for an operator in control room, but also for an operator outside a building for alternation, and then total effective dose is compared with the criterion. The routes for dose evaluation are classified into five patterns, covering three patterns of location of radioactive source (i.e. source inside a building, source released into air, and source leaked into a control room) and covering two patterns of location of an operator (i.e. in control room and outside a building for alternation). Total effective dose by a route for source which is released into air and leaked into a control room is typically the largest contributor, in case of PWR LOCA evaluation, as an example showing relatively severe result. Evaluated dose for this dominant route is significantly affected by two calculations. One is a source term for calculation of radioactive gas release and the other is dispersion calculation in the air for concentration of radioactive gas in the vicinity of a control room. For LOCA 100% Kr,Xe and 50% iodine of total core radionuclide inventory are assumed to be released immediately into containment vessel. This is the most conservative assumption

  17. Internal control as part of prevention irregularities in accounting of budgetary institution

    Directory of Open Access Journals (Sweden)

    O.М. Bunda

    2016-07-01

    Full Text Available The article researches the principles of internal control, the importance, the rationale for the essence of the system of internal control and the legislative building in budgetary institution. It describes the main challenges and problems of practical application of internal control in the normal course of business in modern enterprises. It reveals the following elements of the internal control of a budget institution as: control environment, risk assessment process of a budget institution, information systems, control procedures and control monitoring. The dependence between the effectiveness of accounting and internal control of a budget institution is determined. The paper highlights the methods of evaluation of internal control of a budget institution. This method is recommended for use in the preliminary assessment of control risk budget institution. The concept of «decision» as on the whole and also in particular in internal control is covered. The essential grouping indications of internal control decisions are defined and every type of decisions is characterized. The main directions of improvement of internal control to prevent violations in accounting of a budgetary institution is examined.

  18. Second-Order Necessary Optimality Conditions for Some State-Constrained Control Problems of Semilinear Elliptic Equations

    International Nuclear Information System (INIS)

    Casas, E.; Troeltzsch, F.

    1999-01-01

    In this paper we are concerned with some optimal control problems governed by semilinear elliptic equations. The case of a boundary control is studied. We consider pointwise constraints on the control and a finite number of equality and inequality constraints on the state. The goal is to derive first- and second-order optimality conditions satisfied by locally optimal solutions of the problem

  19. Most recent developments for monitoring and controlling the annulus conditions of Marlim-Sul flexible risers

    Energy Technology Data Exchange (ETDEWEB)

    Rabelo, Alexandre S.; Motta, Antonio; Romero, Antonio; Nunes, Joao P.; Zaganelli Junior, Jose L.; Brack, Marcelo [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The main objective of this paper is to present the recent developments for monitoring and controlling the annulus conditions of flexible risers. PETROBRAS has been monitoring the pressure of permeated gas in the annulus region of some risers in order to infer the eventual occurrence of non-conformities as damage on the riser external sheath, for example. Such occurrence would affect the permeated gas flow pattern, the gas pressurization period and the relief valve opening frequencies. Furthermore, the mentioned occurrence would increase the susceptibility of the steel armors to experience the potential failure mechanism of corrosion. In PETROBRAS, the current monitoring method is characterized by visual and periodic manometer readings from a manometer set installed near each riser end-fitting. The data is recorded in a daily report and analyzed by personnel onshore, who are in charge of comparing data and requesting relief valve's actuation, whenever necessary. The paper illustrates Marlim-Sul Asset experience on monitoring and data processing to control the annulus conditions of flexible risers during operation. It presents the in-house developed methodology to data management and processing. This methodology is based on a daily analysis of the permeated gas data worksheet. Some examples are given to illustrate it. The paper also summarizes current developments, in progress, in order to improve riser integrity management. The first development is being done to implement, in the future, automatic data acquisition and control systems. The purpose of automating this process is to improve methods and techniques for data acquisition, transmission and processing. The second development focuses on applications in which riser top end-fittings are submerged. In this particular scenario, a special system - with a quick connection sub sea device - is under development to allow the connection, by divers, after the riser pull-in, of the riser annulus to the platform gas

  20. An experimental seasonal hydrological forecasting system over the Yellow River basin - Part 1: Understanding the role of initial hydrological conditions

    Science.gov (United States)

    Yuan, Xing; Ma, Feng; Wang, Linying; Zheng, Ziyan; Ma, Zhuguo; Ye, Aizhong; Peng, Shaoming

    2016-06-01

    The hydrological cycle over the Yellow River has been altered by the climate change and human interventions greatly during past decades, with a decadal drying trend mixed with a large variation of seasonal hydrological extremes. To provide support for the adaptation to a changing environment, an experimental seasonal hydrological forecasting system is established over the Yellow River basin. The system draws from a legacy of a global hydrological forecasting system that is able to make use of real-time seasonal climate predictions from North American Multimodel Ensemble (NMME) climate models through a statistical downscaling approach but with a higher resolution and a spatially disaggregated calibration procedure that is based on a newly compiled hydrological observation dataset with 5 decades of naturalized streamflow at 12 mainstream gauges and a newly released meteorological observation dataset including 324 meteorological stations over the Yellow River basin. While the evaluation of the NMME-based seasonal hydrological forecasting will be presented in a companion paper to explore the added values from climate forecast models, this paper investigates the role of initial hydrological conditions (ICs) by carrying out 6-month Ensemble Streamflow Prediction (ESP) and reverse ESP-type simulations for each calendar month during 1982-2010 with the hydrological models in the forecasting system, i.e., a large-scale land surface hydrological model and a global routing model that is regionalized over the Yellow River. In terms of streamflow predictability, the ICs outweigh the meteorological forcings up to 2-5 months during the cold and dry seasons, but the latter prevails over the former in the predictability after the first month during the warm and wet seasons. For the streamflow forecasts initialized at the end of the rainy season, the influence of ICs for lower reaches of the Yellow River can be 5 months longer than that for the upper reaches, while such a difference

  1. DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Dragicevic, Tomislav; Lu, Xiaonan; Vasquez, Juan; Guerrero, Josep

    2015-01-01

    This paper presents a review of control strategies, stability analysis, and stabilization techniques for dc microgrids (MGs). Overall control is systematically classified into local and coordinated control levels according to respective functionalities in each level. As opposed to local control, which relies only on local measurements, some line of communication between units needs to be made available in order to achieve the coordinated control. Depending on the communication method, three basic coordinated control strategies can be distinguished, i.e., decentralized, centralized, and distributed control. Decentralized control can be regarded as an extension of the local control since it is also based exclusively on local measurements. In contrast, centralized and distributed control strategies rely on digital communication technologies. A number of approaches using these three coordinated control strategies to achieve various control objectives are reviewed in this paper. Moreover, properties of dc MG dynamics and stability are discussed. This paper illustrates that tightly regulated point-of-load converters tend to reduce the stability margins of the system since they introduce negative impedances, which can potentially oscillate with lightly damped power supply input filters. It is also demonstrated that how the stability of the whole system is defined by the relationship of the source and load impedances, referred to as the minor loop gain. Several prominent specifications for the minor loop gain are reviewed. Finally, a number of active stabilization techniques are presented.

  2. Stronger than the sum of its parts? The performance implications of peer control combinations in teams

    NARCIS (Netherlands)

    de Jong, Bart A.; Bijlsma-Frankema, Katinka M.; Cardinal, Laura B.

    2014-01-01

    Integrating theorizing on situational strength and complementarity with control theory, we investigate the mediating processes that transmit peer control combination effects to team performance. We argue that two critical peer control mechanisms-norm strength and peer pressure-complement each other

  3. On the conditions of exponential stability in active disturbance rejection control based on singular perturbation analysis

    Science.gov (United States)

    Shao, S.; Gao, Z.

    2017-10-01

    Stability of active disturbance rejection control (ADRC) is analysed in the presence of unknown, nonlinear, and time-varying dynamics. In the framework of singular perturbations, the closed-loop error dynamics are semi-decoupled into a relatively slow subsystem (the feedback loop) and a relatively fast subsystem (the extended state observer), respectively. It is shown, analytically and geometrically, that there exists a unique exponential stable solution if the size of the initial observer error is sufficiently small, i.e. in the same order of the inverse of the observer bandwidth. The process of developing the uniformly asymptotic solution of the system reveals the condition on the stability of the ADRC and the relationship between the rate of change in the total disturbance and the size of the estimation error. The differentiability of the total disturbance is the only assumption made.

  4. Light intensity and production parameters of phytocenoses cultivated on soil-like substrate under controlled [correction of controled] environment conditions.

    Science.gov (United States)

    Tikhomirov, A A; Ushakova, S A; Gribovskaya, I A; Tirranen, L S; Manukovsky, N S; Zolotukhin, I G; Karnachuk, R A; Gros, J B; Lasseur, Ch

    2003-01-01

    To increase the degree of closure of biological life support systems of a new generation, we used vermicomposting to involve inedible phytomass in the intra-system mass exchange. The resulting product was a soil-like substrate, which was quite suitable for growing plants (Manukovsky et al. 1996, 1997). However, the soil like substrate can be regarded as a candidate for inclusion in a system only after a comprehensive examination of its physical, chemical, and other characteristics. An important criterion is the ability of the soil-like substrate to supply the necessary mineral elements to the photosynthesizing component under the chosen cultivation conditions. Thus, the purpose of this work was to study the feasibility of enhancing the production activity of wheat and radish crops by varying the intensity of photosynthetically active radiation, without decreasing the harvest index. The increase of light intensity from 920 to 1150 micromoles m-2 s-1 decreased the intensity of apparent photosynthesis of the wheat crops and slightly increased the apparent photosynthesis of the radish crops The maximum total and grain productivity (kg/m2) of the wheat crops was attained at the irradiance of 920 micromoles m-2 s-1. Light intensity of 1150 micromoles m-2 s-1 decreased the productivity of wheat plants and had no significant effect on the productivity of the radish crops (kg/m2) as compared to 920 micromoles m-2 s-1. The qualitative and quantitative composition of microflora of the watering solution and substrate was determined by the condition of plants, developmental phase and light intensity. By the end of wheat growth under 1150 micromoles m-2 s-1 the numbers of bacteria of the coliform family and phytopathogenic bacteria in the watering solution and substrate were an order of magnitude larger than under other illumination conditions. The obtained data suggest that the cultivation of plants in a life support system on soil-like substrate from composts has a number of

  5. The Effects of Fluency Enhancing Conditions on Sensorimotor Control of Speech in Typically Fluent Speakers: An EEG Mu Rhythm Study

    Directory of Open Access Journals (Sweden)

    Tiffani Kittilstved

    2018-04-01

    Full Text Available Objective: To determine whether changes in sensorimotor control resulting from speaking conditions that induce fluency in people who stutter (PWS can be measured using electroencephalographic (EEG mu rhythms in neurotypical speakers.Methods: Non-stuttering (NS adults spoke in one control condition (solo speaking and four experimental conditions (choral speech, delayed auditory feedback (DAF, prolonged speech and pseudostuttering. Independent component analysis (ICA was used to identify sensorimotor μ components from EEG recordings. Time-frequency analyses measured μ-alpha (8–13 Hz and μ-beta (15–25 Hz event-related synchronization (ERS and desynchronization (ERD during each speech condition.Results: 19/24 participants contributed μ components. Relative to the control condition, the choral and DAF conditions elicited increases in μ-alpha ERD in the right hemisphere. In the pseudostuttering condition, increases in μ-beta ERD were observed in the left hemisphere. No differences were present between the prolonged speech and control conditions.Conclusions: Differences observed in the experimental conditions are thought to reflect sensorimotor control changes. Increases in right hemisphere μ-alpha ERD likely reflect increased reliance on auditory information, including auditory feedback, during the choral and DAF conditions. In the left hemisphere, increases in μ-beta ERD during pseudostuttering may have resulted from the different movement characteristics of this task compared with the solo speaking task. Relationships to findings in stuttering are discussed.Significance: Changes in sensorimotor control related feedforward and feedback control in fluency-enhancing speech manipulations can be measured using time-frequency decompositions of EEG μ rhythms in neurotypical speakers. This quiet, non-invasive, and temporally sensitive technique may be applied to learn more about normal sensorimotor control and fluency enhancement in PWS.

  6. Novel Digital Features Discriminate Between Drought Resistant and Drought Sensitive Rice Under Controlled and Field Conditions

    Directory of Open Access Journals (Sweden)

    Lingfeng Duan

    2018-04-01

    Full Text Available Dynamic quantification of drought response is a key issue both for variety selection and for functional genetic study of rice drought resistance. Traditional assessment of drought resistance traits, such as stay-green and leaf-rolling, has utilized manual measurements, that are often subjective, error-prone, poorly quantified and time consuming. To relieve this phenotyping bottleneck, we demonstrate a feasible, robust and non-destructive method that dynamically quantifies response to drought, under both controlled and field conditions. Firstly, RGB images of individual rice plants at different growth points were analyzed to derive 4 features that were influenced by imposition of drought. These include a feature related to the ability to stay green, which we termed greenness plant area ratio (GPAR and 3 shape descriptors [total plant area/bounding rectangle area ratio (TBR, perimeter area ratio (PAR and total plant area/convex hull area ratio (TCR]. Experiments showed that these 4 features were capable of discriminating reliably between drought resistant and drought sensitive accessions, and dynamically quantifying the drought response under controlled conditions across time (at either daily or half hourly time intervals. We compared the 3 shape descriptors and concluded that PAR was more robust and sensitive to leaf-rolling than the other shape descriptors. In addition, PAR and GPAR proved to be effective in quantification of drought response in the field. Moreover, the values obtained in field experiments using the collection of rice varieties were correlated with those derived from pot-based experiments. The general applicability of the algorithms is demonstrated by their ability to probe archival Miscanthus data previously collected on an independent platform. In conclusion, this image-based technology is robust providing a platform-independent tool for quantifying drought response that should be of general utility for breeding and functional

  7. Surgical Outcome of Intermittent Exotropia With Improvement in Control Grade Subsequent to Part-time Preoperative Occlusion Therapy.

    Science.gov (United States)

    Bang, Seung Pil; Lee, Dong Cheol; Lee, Se Youp

    2018-01-01

    To evaluate the effect of improvement in the control grade of intermittent exotropia using part-time occlusion therapy on the final postoperative outcome. Control of intermittent exotropia was graded as good, fair, or poor in 89 consecutive patients with intermittent exotropia during their first visit. The patients were reevaluated after part-time preoperative occlusion therapy and divided into two groups (improvement and no improvement) according to whether they showed improvement in control grade. The surgical success rate was compared retrospectively between the two groups. The mean angle of deviation on the first visit was 27.61 ± 5.40 prism diopters (PD) at distance and 29.82 ± 5.28 PD at near. There were significant improvements in the angles of deviation for distance (26.17 ± 5.09 PD) and near (27.26 ± 5.56 PD) after part-time occlusion (both P Part-time occlusion therapy improves the control grade of intermittent exotropia, leading to a better likelihood of successful surgery and a reduction of the angles of deviation for distance and near. [J Pediatr Ophthalmol Strabismus. 2018;55(1):59-64.]. Copyright 2017, SLACK Incorporated.

  8. An alternative method for noise analysis using pixel variance as part of quality control procedures on digital mammography systems.

    NARCIS (Netherlands)

    Bouwman, R.; Young, K.; Lazzari, B.; Ravaglia, V.; Broeders, M.J.M.; Engen, R. van

    2009-01-01

    According to the European Guidelines for quality assured breast cancer screening and diagnosis, noise analysis is one of the measurements that needs to be performed as part of quality control procedures on digital mammography systems. However, the method recommended in the European Guidelines does

  9. Particle control in DIII-D with helium glow discharge conditioning

    International Nuclear Information System (INIS)

    Jackson, G.L.; Taylor, T.S.; Taylor, P.L.

    1990-01-01

    Helium glow discharge conditioning of DIII-D is routinely used before every tokamak discharge to desorb hydrogen from the graphite tiles, which are the plasma facing surfaces for the floor, inner wall and top of the vessel. In addition to reducing hydrogen fuelling of the plasma by the graphite surfaces, helium glow discharges are also effective in removing low-Z impurities, primarily in the form of carbon monoxide and hydrocarbons, and this has permitted higher current divertor operation and more rapid recovery from tokamak disruptions. Since the implementation of repetitive helium glow wall conditioning, the parameter space in which tokamak discharges in DIII-D can be obtained has been expanded to include the first observations of limiter H-mode confinement, the Ohmic H-mode with periods of up to 150 ms that are free of edge localized modes, more reliable low q operation with volume averaged beta of up to 9.3%, improved control over locked modes and plasma discharges at lower electron density. (author). 37 refs, 12 figs, 1 tab

  10. Temperature effect on rose downy mildew development under environmental controlled conditions

    Directory of Open Access Journals (Sweden)

    Juan José Filgueira D.

    2014-04-01

    Full Text Available The rose downy mildew disease, caused by Peronospora sparsa Berkeley, is one of the most important that affect rose crops in Colombia. To manage this disease, flower growers must deal with high-costs due to the excessive application of fungicides, but without good results. Studies on P. sparsa behavior have shown its narrow relationship with environmental conditions. In this study, the temperature effect was evaluated during the infection and sporulation of P. sparsa in Charlotte leaflets, a susceptible commercial variety, through an environmental controlled conditions system. Infection and sporulation were observed at different temperatures in a range of from 4 to 40°C. Infection with the absence of or very low sporulation was observed at 4°C. The most favorable pathogen responses were between 15 and 18°C in terms of inoculum concentration and sporulation percentage. There was no infection or leaflet change above 35°C. According to the results, sporulation can occur from 4 to 33°C, confirming the fact that P. sparsa is able to reproduce throughout a wide temperature range.

  11. The control of a free-piston engine generator. Part 1: Fundamental analyses

    Energy Technology Data Exchange (ETDEWEB)

    Mikalsen, R.; Roskilly, A.P. [Sir Joseph Swan Institute for Energy Research, Newcastle University, Newcastle upon Tyne, NE1 7RU, England (United Kingdom)

    2010-04-15

    Free-piston engines are under investigation by a number of research groups due to potential fuel efficiency and exhaust emissions advantages over conventional technology. The main challenge with such engines is the control of the piston motion, and this has not yet been fully resolved for all types of free-piston engines. This paper discusses the basic features of a single piston free-piston engine generator under development at Newcastle University and investigates engine control issues using a full-cycle simulation model. Control variables and disturbances are identified, and a control strategy is proposed. It is found that the control of the free-piston engine is a challenge, but that the proposed control strategy is feasible. Engine speed control does, however, represent a challenge in the current design. (author)

  12. Groundwater flow analysis on local scale. Setting boundary conditions of groundwater flow analysis on site scale model in the former part of the step 3

    International Nuclear Information System (INIS)

    Onoe, Hironori; Saegusa, Hiromitsu

    2005-07-01

    Japan Nuclear Cycle Development Institute has been conducting a wide range of geoscientific research in order to build a foundation for multidisciplinary studies of the deep geological environment as a basis of research and development for geological disposal of nuclear wastes. Ongoing geoscientific research programs include the Regional Hydrogeological Study (RHS) project and Mizunami Underground Research Laboratory (MIU) project in the Tono region, Gifu Prefecture. The main goal of these projects is to establish comprehensive techniques for investigation, analysis, and assessment of the deep geological environment at several spatial scales. The RHS project is a local scale study for understanding the groundwater flow system from the recharge area to the discharge area. The Surface-based Investigation Phase of the MIU project is a mainly site scale study for understanding the deep geological environment immediately surrounding the MIU construction site using a multiphase, iterative approach. In this study, the hydrogeological modeling and groundwater flow analysis on the Local scale were carried out in order to set boundary conditions of the site scale model based on the data obtained from surface-based investigations in the former part of the Step 3 in site scale of the MIU project. As a result of the study, the uncertainty of hydrogeological model of the local scale and boundary conditions for the site scale model is decreased as stepwise investigation, and boundary conditions for groundwater flow analysis on the site scale model for the former part of the Step 3 could be obtained. (author)

  13. Radiation protection at the RA Reactor in 1985, Part -2, Annex 2b, Environmental Radioactivity control, Control of air contamination

    International Nuclear Information System (INIS)

    Patic, D.; Smiljanic, R.; Zaric, M.; Savic, Z.; Ristic, D.

    1985-01-01

    During the period from November 1984 - November 1985, within the radioactivity control on the Vinca Institute site air contamination radioactive aerosol contents was measured. Control was done on 4 measuring stations, two in the Institute and two locations in the direction of wind i.e. Belgrade, 2 km and 7 km away from the Institute respectively. This position of the measuring locations enables control of radiation safety of the Institute, as well as environment of Belgrade taking into account the existence of the reactor and other possible contaminants in the Institute [sr

  14. Impact of controlled release urea on maize yield and nitrogen use efficiency under different water conditions.

    Directory of Open Access Journals (Sweden)

    Guanghao Li

    Full Text Available Controlled release urea (CRU has been widely adopted to increase nitrogen (N use efficiency and maize production, but the impacts can range widely depending on water availability in the soil. In an experiment using Zhengdan 958 (a popular summer maize hybrid, three levels of water treatments (adequate water condition [W3], which maintained soil moisture at about 75% ± 5% of the soil's field capacity; mild water stress [W2], which maintained moisture content at 55% ± 5% of field capacity; and severe water stress [W1], which had a moisture content of 35% ± 5% of field capacity and four levels of controlled release urea fertilizer (N0, N1, N2 and N3 were 0, 105, 210 and 315 kg N ha-1, respectively were compared in a rainout shelter system with soil. The results revealed that CRU had significant effects on maize yields and N use efficiencies under different water conditions. The mean yields increased with increasing water levels and showed significant differences. Under W1, the accumulation of dry matter and N were limited, and N internal efficiency (NIE and the apparent recovery efficiency of applied N (REN decreased with N increases; yields of N1, N2, and N3 were similar. Under W2, the dry matter and N accumulation, as well as the yield, showed an increasing trend with an increase in N application, and the NIE and REN of N3 showed no difference from N2. Under W3, yields of N2 and N3 were similar and they were significantly higher than that of N1, but the agronomic N use efficiency (ANUE, REN, and the physiological NUE (PNUE of N2 were 54.2, 34.9, and 14.4% higher, respectively, than those of N3. N application beyond the optimal N rate did not consistently increase maize yield, and caused a decrease in N use efficiencies. Highest overall dry matter, N accumulation, and yields were observed with N3 under W2, and those showed no differences with N2 and N3 under W3. Under this experimental condition, the CRU of 210 kg ha-1 was optimized when soil

  15. Control of Greenhouse Environmental Conditions with IOT Based Monitoring and Analysis System

    Directory of Open Access Journals (Sweden)

    Ali Çaylı

    2017-10-01

    Full Text Available Wireless sensor networks applications and inter-machine communication (M2M, called the Internet of Things, help decision-makers to control complex systems thanks to the low data-rate and cost-effective data collection and analysis. These technologies offer new possibilities to monitor environmental management and agricultural policies, and to improve agricultural production, especially in low-income rural areas. In this study, IoT is proposed with a low cost, flexible and scalable data collection and analysis system. For this purpose, open source hardware microprocessor cards and sensors are stored in the greenhouse computer database using the IEEE 802.15.4 Zigbee wireless communication protocol. The data can be analyzed by greenhouse computer analysis software, which is developed with the PHP programming language. It is possible to monitor the real time data from the greenhouse computer. Also alert rules definitions can be made and the system was tested in greenhouse conditions. It has been observed that it performs operations steadily such as data transfer, sensor measurements and data processing. The proposed system may be useful for monitoring indoor climate and controlling ventilation, irrigation and heating systems, especially for small enterprises due to the modular structure.

  16. Unique genetic loci identified for emotional behavior in control and chronic stress conditions.

    Directory of Open Access Journals (Sweden)

    Kimberly AK Carhuatanta

    2014-10-01

    Full Text Available An individual’s genetic background affects their emotional behavior and response to stress. Although studies have been conducted to identify genetic predictors for emotional behavior or stress response, it remains unknown how prior stress history alters the interaction between an individual’s genome and their emotional behavior. Therefore, the purpose of this study is to identify chromosomal regions that affect emotional behavior and are sensitive to stress exposure. We utilized the BXD behavioral genetics mouse model to identify chromosomal regions that predict fear learning and emotional behavior following exposure to a control or chronic stress environment. 62 BXD recombinant inbred strains and C57BL/6 and DBA/2 parental strains underwent behavioral testing including a classical fear conditioning paradigm and the elevated plus maze. Distinct quantitative trait loci (QTLs were identified for emotional learning, anxiety and locomotion in control and chronic stress populations. Candidate genes, including those with already known functions in learning and stress were found to reside within the identified QTLs. Our data suggest that chronic stress history reveals novel genetic predictors of emotional behavior.

  17. Energetic conditions promoting top-down control of prey by predators.

    Directory of Open Access Journals (Sweden)

    Kristin N Marshall

    Full Text Available Humans remove large amounts of biomass from natural ecosystems, and large bodied high trophic level animals are especially sensitive and vulnerable to exploitation. The effects of removing top-predators on food webs are often difficult to predict because of limited information on species interaction strengths. Here we used a three species predator-prey model to explore relationships between energetic properties of trophodynamic linkages and interaction strengths to provide heuristic rules that indicate observable energetic conditions that are most likely to lead to stable and strong top-down control of prey by predator species. We found that strong top-down interaction strengths resulted from low levels of energy flow from prey to predators. Strong interactions are more stable when they are a consequence of low per capita predation and when predators are subsidized by recruitment. Diet composition also affects stability, but the relationship depends on the form of the functional response. Our results imply that for generalist satiating predators, strong top-down control on prey is most likely for prey items that occupy a small portion of the diet and when density dependent recruitment is moderately high.

  18. Sleep Deprivation Diminishes Attentional Control Effectiveness and Impairs Flexible Adaptation to Changing Conditions.

    Science.gov (United States)

    Whitney, Paul; Hinson, John M; Satterfield, Brieann C; Grant, Devon A; Honn, Kimberly A; Van Dongen, Hans P A

    2017-11-22

    Insufficient sleep is a global public health problem resulting in catastrophic accidents, increased mortality, and hundreds of billions of dollars in lost productivity. Yet the effect of sleep deprivation (SD) on decision making and performance is often underestimated by fatigued individuals and is only beginning to be understood by scientists. The deleterious impact of SD is frequently attributed to lapses in vigilant attention, but this account fails to explain many SD-related problems, such as loss of situational awareness and perseveration. Using a laboratory study protocol, we show that SD individuals can maintain information in the focus of attention and anticipate likely correct responses, but their use of such a top-down attentional strategy is less effective at preventing errors caused by competing responses. Moreover, when the task environment requires flexibility, performance under SD suffers dramatically. The impairment in flexible shifting of attentional control we observed is distinct from lapses in vigilant attention, as corroborated by the specificity of the influence of a genetic biomarker, the dopaminergic polymorphism DRD2 C957T. Reduced effectiveness of top-down attentional control under SD, especially when conditions require flexibility, helps to explain maladaptive performance that is not readily explained by lapses in vigilant attention.

  19. Contamination control requirements implementation for the James Webb Space Telescope (JWST), part 2: spacecraft, sunshield, observatory, and launch

    Science.gov (United States)

    Wooldridge, Eve M.; Schweiss, Andrea; Henderson-Nelson, Kelly; Woronowicz, Michael; Patel, Jignasha; Macias, Matthew; McGregor, R. Daniel; Farmer, Greg; Schmeitzky, Olivier; Jensen, Peter; Rumler, Peter; Romero, Beatriz; Breton, Jacques

    2014-09-01

    This paper will continue from Part 1 of JWST contamination control implementation. In addition to optics, instruments, and thermal vacuum testing, JWST also requires contamination control for a spacecraft that must be vented carefully in order to maintain solar array and thermal radiator thermal properties; a tennis court-sized sunshield made with 1-2 mil Kapton™ layers that must be manufactured and maintained clean; an observatory that must be integrated, stowed and transported to South America; and a rocket that typically launches commercial payloads without contamination sensitivity. An overview of plans developed to implement contamination control for the JWST spacecraft, sunshield, observatory and launch vehicle will be presented.

  20. Energy performance and optimal control of air-conditioned buildings with envelopes enhanced by phase change materials

    International Nuclear Information System (INIS)

    Zhu Na; Wang Shengwei; Ma Zhenjun; Sun Yongjun

    2011-01-01

    Highlights: → Impact of PCM on the energy consumption and peak load demand as well as electricity cost of air-conditioned buildings. → Impact of load shifting control on energy consumption, peak load and electricity cost of air-conditioned PCM buildings. → Impact of demand limiting control on energy consumption, peak load and electricity cost of air-conditioned PCM buildings. → Energy/cost effects of different control strategies and use of PCM in energy-plus-demand-based pricing policy. → Energy/cost effects of different control strategies and use of PCM in time-based pricing policy. - Abstract: Studies are conducted to investigate the impacts of shape-stabilized phase change material (SSPCM) and different control strategies on the energy consumption and peak load demand as well as electricity cost of building air-conditioning systems at typical summer conditions in two climates (subtropical and dry continental climates). An office building using a typical variable air volume (VAV) air-conditioning system was selected and simulated as the reference building in this study. Its envelopes were enhanced by integrating the SSPCM layers into its walls while the air-conditioning system and other configurations of the building remained unchanged. The building system was tested under two typical weather conditions and two typical electricity pricing policies (i.e. time-based pricing and energy-plus-demand-based pricing). Test results show that the use of SSPCM in the building could reduce the building electricity cost significantly (over 11% in electricity cost reduction and over 20% in peak load reduction), under two pricing policies by using load shifting control and demand limiting control respectively. This paper presents the test results and the evaluation on the energy performance and the optimal control strategies of air-conditioned commercial buildings with envelopes enhanced by SSPCM.