WorldWideScience

Sample records for contrast medium gd-dtpa

  1. Significance of contrast enhancement with Gd-DTPA in evaluation of pituitary adenomas; Znaczenie wzmocnienia kontrastowego Gd-DTPA w ocenie gruczolakow przysadki

    Energy Technology Data Exchange (ETDEWEB)

    Paprzycki, W.; Liebert, W.; Gradzki, J.; Sosnowski, P.; Stajgis, M. [Osrodek Diagnostyki Obrazowej IR, Akademia Medyczna, Poznan (Poland)]|[Zaklad Neuroradiologii, Akademia Medyczna, Poznan (Poland)]|[Klinika Neurochirurgii, Akademia Medyczna, Poznan (Poland)

    1994-12-31

    Results of MR examinations in 136 patients with suspected pituitary adenoma were evaluated retrospectively. Presence of 40 microadenomas and 48 macroadenomas was confirmed. Contrast enhancement with Gd-DTPA increased diagnostic efficacy in 65% of cases of microadenomas. Contrast enhancement with Gd-DTPA was less useful in cases of macroadenomas and enable the more detailed evaluation of tumor margins in 31 %, tumor relation to cavernous sinus in 21% and tumor relation to optic chiasm in 6% of cases only. Authors suggest, that contrast enhancement with Gd-DTPA is indispensable and should be performed routinely in evaluation of pituitary gland in patients with suspected microadenoma. (author) 10 refs, 5 figs, 3 tabs

  2. The primary applications of Gd-DTPA as an oral negative gastrointestinal contrast agent for MRCP

    International Nuclear Information System (INIS)

    Chen Yanping; Zhang Xuelin; Cheng Guanxun; Chang Renmin; Zhang Yuzhong; Cang Peng; Xia Qiong

    2003-01-01

    Objective: Using oral Gd-DTPA as a negative contrast agent to null the bowel signal during MR cholangiopancreatography (MRCP) to improve the quality of MRCP. Methods: A phantom study was performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in MRCP. 15 patients suspected of biliary tract and pancreatic disease were performed with MRCP before and after using 250 ml oral contrast agents (1:5 diluted Gd-DTPA, 1.488 g/L). All MR images were acquired using a 1.5 T whole body MR scanner (Vision Plus, Siemens). MRCP was acquired using two-dimensional single slice fast spin-echo sequence and HASTE (half-fourier acquisition single-shot fast spin echo) sequence. Results: The phantom study showed that the dilution ratio 1:5 of Gd-DTPA oral contrast agent was best in decreasing the signal intensity both in T 2 WI (59.3%) and in HASTE sequence (82.45%). All the dilution ratio of Gd-DTPA oral contrast agent decreased the signal intensity up to 90% on single slice MRCP. In all the patients the high signal intensity from the stomach and intestinal fluid was completely suppressed. The depictions of common bile duct and pancreatic duct were markedly improved by the oral contrast agent (P<0.05). Conclusion: 1:5 diluted (1.488 g/L) oral MR contrast agent Gd-DTPA can be an effective and safe negative contrast agent in eliminating signal intensity of the gastrointestinal tract, thus improving the depiction of the biliary system in MRCP

  3. Synthesis and evaluation of novel polysaccharide-Gd-DTPA compounds as contrast agent for MRI

    Science.gov (United States)

    Sun, Guoying; Feng, Jianghua; Jing, Fengying; Pei, Fengkui; Liu, Maili

    2003-09-01

    Macromolecular conjugates of two kinds of natural polysaccharides, that from Panax quinquefolium linn (PQPS) and Ganoderma applanatum pat (GAPS), with gadolinium-diethylenetriaminepenta-acetic acid (Gd-DTPA) have been synthesized and characterized by means of FTIR, elementary analysis and ICP-AES. Their stability was investigated by competition study with Ca 2+, EDTA (ethylenediaminetetraacetic acid) and DTPA. Polysaccharide-bound complexes exhibit T1 relaxivities of 1.5-1.7 times that of Gd-DTPA in D 2O at 25°C and 9.4 T. MR imaging of Sprague-Dawley (SD) rats showed remarkable enhancement in rat liver and kidney after i.v. injection of these two complexes: liver parenchyma 60.9±5.6%, 57.8±7.4% at 65-85 min; kidney 144.9±14.5%, 199.9±25.4% at 10-30 min for PQPS-Gd-DTPA, GAPS-Gd-DTPA at gadolinium dose of 0.083 and 0.082 mmol/kg, respectively. Our preliminary in vivo and in vitro study indicates that the two kinds of polysaccharide-bound complexes are potential tissue-specific contrast agents for MRI.

  4. Gd-DTPA: a bowel contrast agent for magnetic resonance imaging of the abdomen

    International Nuclear Information System (INIS)

    Vlahos, L.; Gouliamos, A.; Clauss, W.; Kalovidouris, A.; Hadjiioannou, A.; Athanasopoulou, A.; Trakadas, S.; Papavasiliou, C.

    1992-01-01

    Forty patients with suspected pathology in the abdomen and pelvis have been investigated with MRI before and after administration of Gd-DTPA as an oral or rectal solution. The findings are analysed with respect to: (a) filling of the GI tract; (b) contrast in the region of interest, surrounding fat and vessels; (c) diagnostic yield in comparison to non-enhanced MRI and contrast CT. At a concentration of 1 mmol/l Gd-DTPA provided consistent positive contrast in the stomach and bowel in all cases. In 57.5% of cases we achieved complete filling of the GI tract. The opacification in the region of interest was good or satisfactory in 90% of cases. The diagnostic value of contrast MRI was better in 93% of cases than the non-enhanced MRI of the abdomen. In comparison with contrast CT, the contrast MRI was better or of the same value in 92% of cases. Despite the disadvantage of poor fat-to-bowel contrast (35% of cases were classified as poor), it is concluded that Gd-DTPA-enhanced MRI provides good delineation of organs adjacent to the bowel so this contrast agent has potential for a future role in abdominal MRI. (orig.)

  5. Diagnostic value of Gd-DTPA in mediastinal masses

    International Nuclear Information System (INIS)

    Hahn, D.; Naegele, M.; Seelos, K.; Lissner, J.A.

    1987-01-01

    Thirty-three patients with different mediastinal masses were examined with a 1.0-T Magnetom using Gd-DTPA. In all patients short spin echo sequences without and with Gd-DTPA as well as fast imaging sequences with reduced echo delay times or different flip angles in gradient echoes were compared. The relative enhancement rate in tumor tissue, fat, muscle and bone marrow was evaluate by signal-intensity measurement before and after application of contrast medium. The uptake of contrast medium in benign masses and inflammatory diseases was significantly lower than in malignant masses. The good enhancement of mediastinal tumors allowed a better differentiation of the inner structure of the tumor. A better differential diagnosis of malignant tumors could not be done by measuring the signal intensity enhancement rate because of overlapping values. Gd-DTPA-enhanced MR imaging may, however, be helpful in follow-up studies in patients with malignant lymphomas

  6. The synthesis of a D-glucosamine contrast agent, Gd-DTPA-DG, and its application in cancer molecular imaging with MRI

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Wei [Department of Nuclear Medicine, Affiliated Hospital of Luzhou Medical College, Luzhou, Sichuan 646000 (China); Chen Yue, E-mail: chenyue5523@126.com [Department of Nuclear Medicine, Affiliated Hospital of Luzhou Medical College, Luzhou, Sichuan 646000 (China); Guo Dajing [Department of Radiology, Second Affiliated Hospital of Chongqing Medical University, Chongqing 400010 (China); Huang Zhanwen; Cai Liang [Department of Nuclear Medicine, Affiliated Hospital of Luzhou Medical College, Luzhou, Sichuan 646000 (China); He Ling [West China School of Pharmacy, Sichuan University, Chengdu, Sichuan 610041 (China)

    2011-09-15

    Objective: The purpose of this study is to describe the synthesis of Gadolinium-diethylenetriamine pentaacetic acid-deoxyglucosamine (Gd-DTPA-DG) which is a D-glucosamine metabolic MR imaging contrast agent. We will also discuss its use in a pilot MRI study using a xenograft mouse model of human adenocarcinoma. Methods: This novel contrast agent was specifically studied because of its ability to 'target' metabolically active tumor tissues. In this study Gd-DTPA-DG is used to investigate how tumor tissues would react to a dose of 0.2 mmol Gd/kg over a 120 min exposure in a xenograft mouse model. These experiments used athymic mice implanted with human pulmonary adenocarcinoma (A549) as demonstrated by dynamic MRI. Alternately, another contrast agent that is not specific for targeting, Gd-DTPA, was used as the control at a similar dose of gadolinium. Efficacy of the targeted contrast agent was assessed by measuring relaxation rate in vitro and signal intensity (SI) in vivo. Statistical differences were calculated using one-way analysis of variance. Results: The synthesized Gd-DTPA-DG was shown to improve the contrast of tumor tissue in this model. Gd-DTPA-DG was also shown to have a similar pharmacokinetic rate but generated a higher relaxation rate in tumor tissues relative to the control contrast Gd-DTPA. In comparison to the pre-contrast imaging, the SI of tumor tissue in the experimental group was shown to be significantly increased at 15 min after injection of Gd-DTPA-DG (p < 0.001). The enhanced signal intensity spread from the edge of the tumor to the center and seemed to strengthen the idea that MRI performance would be useful in different tumor tissues. Conclusion: This preliminary study shows that this new chelated contrast agent, Gd-DTPA-DG, can be specifically targeted to accumulation in tumor tissue as compared to normal tissues. This targeted paramagnetic contrast agent has potential for specific cancer molecular imaging with MRI.

  7. MR angiography of collateral arteries in a hind limb ischemia model: comparison between blood pool agent Gadomer and small contrast agent Gd-DTPA.

    Directory of Open Access Journals (Sweden)

    Karolien Jaspers

    Full Text Available The objective of this study was to compare the blood pool agent Gadomer with a small contrast agent for the visualization of ultra-small, collateral arteries (diameter0.10. Inter-observer variation was 24% and 18% for Gadomer and Gd-DTPA, respectively. In conclusion, blood pool agent Gadomer improved vessel conspicuity compared to Gd-DTPA. Steady-state MRA can be considered as an excellent non-invasive alternative to intra-arterial XRA for the visualization of ultra-small collateral arteries.

  8. Gd-DTPA-enhanced dynamic MR imaging of the kidney

    International Nuclear Information System (INIS)

    Choyke, P.L.; Frank, J.A.; Carvlin, M.J.; Austin, H.; Girton, M.J.; Inscoe, S.; Black, J.

    1988-01-01

    Dynamic Gd-DTPA-enhanced MR imaging potentially can provide both anatomic and physiologic information about the kidneys. The authors performed 42 animal imaging studies with 1.5-T MR imaging after a bolus of Gd-DTPA (0.1 mmol/kg) was given. A reproducible pattern of enhancement was observed that could be divided into three phases. In phase I a cortical blush was seen, representing intravascular contrast. Phase II represented the tubular concentration of Gd-DTPA and was depicted as a centrally migrating band that reversed direction in the inner medulla. Phase III was a gradual darkening of the inner medulla caused by concentration in the collecting ducts. This pattern was predictably altered by hydration status. The patterns observed reflected alterations in concentration of Gd-DTPA occurring in the renal tubules and collecting ducts. Gd-DTPA-enhanced renal MR imaging is promising as a renal imaging technique

  9. Brain Delivery of Drug and MRI Contrast Agent: Detection and Quantitative Determination of Brain Deposition of CPT-Glu Using LC-MS/MS and Gd-DTPA Using Magnetic Resonance Imaging

    Science.gov (United States)

    Tabanor, Kayann; Lee, Phil; Kiptoo, Paul; Choi, In-Young; Sherry, Erica B.; Eagle, Cheyenne Sun; Williams, Todd D.; Siahaan, Teruna J.

    2015-01-01

    Successful treatment and diagnosis of neurological diseases depend on reliable delivery of molecules across the blood-brain barrier (BBB), which restricts penetration of pharmaceutical drugs and diagnostic agents into the brain. Thus, developing new non-invasive strategies to improve drug delivery across the BBB is critically needed. This study was aimed at evaluating the activity of HAV6 peptide (Ac-SHAVSS-NH2) in improving brain delivery of camptothecin-glutamate (CPT-Glu) conjugate and gadolinium-diethylenetriaminepentaacetate (Gd-DTPA) contrast agent in Sprague-Dawley rats. Brain delivery of both CPT-Glu and Gd-DTPA was evaluated in an in situ rat brain perfusion model in the presence and absence of HAV6 peptide (1.0 mM). Gd-DTPA (0.6 mmol/kg) was intravenously (i.v.) administered with and without HAV6 peptide (0.019 mmol/kg) in rats. The detection and quantification of CPT-Glu and Gd-DTPA in the brain were carried out by LC-MS/MS and quantitative magnetic resonance imaging (MRI), respectively. Rats perfused with CPT-Glu in combination with HAV6 had significantly higher deposition of drug in the brain compared to CPT-Glu alone. MRI results also showed that administration of Gd-DTPA in the presence of HAV6 peptide led to significant accumulation of Gd-DTPA in various regions of the brain in both the in situ rat brain perfusion and in vivo studies. All observations taken together indicate that HAV6 peptide can disrupt the BBB and enhance delivery of small molecules into the brain. PMID:26705088

  10. In vitro chondrocyte toxicity following long-term, high-dose exposure to Gd-DTPA and a novel cartilage-targeted MR contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Midura, Sharon; Midura, Ronald J. [Cleveland Clinic, Biomedical Engineering, Lerner Research Institute, Cleveland, OH (United States); Schneider, Erika [Cleveland Clinic, Imaging Institute, A21, Cleveland, OH (United States); NitroSci Pharmaceuticals, New Berlin, WI (United States); Rosen, Gerald M. [University of Maryland School of Pharmacy, Department of Pharmaceutical Sciences, Baltimore, MD (United States); NitroSci Pharmaceuticals, New Berlin, WI (United States); Winalski, Carl S. [Cleveland Clinic, Biomedical Engineering, Lerner Research Institute, Cleveland, OH (United States); Cleveland Clinic, Imaging Institute, A21, Cleveland, OH (United States)

    2017-01-15

    To determine the concentrations exhibiting toxicity of a cartilage-targeted magnetic resonance imaging contrast agent compared with gadopentetate dimeglumine (Gd-DT-PA) in chondrocyte cultures. A long-term Swarm rat chondrosarcoma chondrocyte-like cell line was exposed for 48 h to 1.0-20 mM concentrations of diaminobutyl-linked nitroxide (DAB4-DLN) citrate, 1.0-20 mM Gd-DTPA, 1.0 μM staurosporine (positive control), or left untreated. Cell appearance, 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assays of metabolic activity, quantitative PicoGreen assays of DNA content, and calcein-AM viability assays were compared. At 1.0-7.5 mM, minimal decrease in cell proliferation was found for both agents. At all doses of both agents, cell culture appearances were similar after 24 h of treatment. At the higher doses, differences in cell culture appearance were found after 48 h of treatment, with dose-dependent declines in chondrocyte populations for both agents. Concentration-dependent declines in DNA content and calcein fluorescence were found after 48 h of treatment, but beginning at a lower dose of DAB4-DLN citrate than Gd-DTPA. Dose-dependent decreases in MTT staining (cell metabolism) were apparent for both agents, but larger effects were evident at a lower dose for DAB-DLN citrate. Poor MTT staining of cells exposed for 48 h to 20 mM DAB4-DLN citrate probably indicates dead or dying cells. The minimal effect of the long-term exposure of model chondrocyte cell cultures to DAB4-DLN citrate and Gd-DTPA concentrations up to 7.5 mM (3x typical arthrographic administration) is supporting evidence that these doses are acceptable for MR arthrography. The findings are reassuring given that the experimental exposure to the contrast agents at sustained concentrations was much longer than when used clinically. (orig.)

  11. Clinical phase II study with Gd-DTPA (dimeglumine gadopentetate, SHL 451 A) in brain tumor and cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, Kohki; Aoki, Shigeki; Machida, Tohru and others

    1988-06-01

    A clinical phase II study with Gd-DTPA, the first contrast medium for MRI, was performed in 109 cases, a total of 114 studies mainly with brain tumor. In this study, one of the three concentrations of Gd-DTPA, 0.05 mmol/kg, 0.10 mmol/kg or 0.15 mmol/kg was used in each patient. It was elucidated that especially 0.10 and 0.15 Gd-DTPA were useful in detecting disruption or abscence of BBB and distinguishing tumor from edema. The side-effect observed was only a slight urticaria which was seen with 0.15 mmol/kg Gd-DTPA. Accordingly, it was estimated that the standard concentration of Gd-DTPA would be 0.10 mmol/kg. As this contrast medium was safe, and clinically useful in detecting diseases of the central nervous system, it was concluded that the shift to the clinical phase III trial is possible.

  12. Trial of MR cholangiopancreatography combined with Gd-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Koshi; Ha-Kawa, S.K.; Kurokawa, Hiroaki; Nakano, Yoshihisa; Tanaka, Yoshimasa [Kansai Medical Univ., Moriguchi, Osaka (Japan); Asakura, Tamaki; Maeda, Toshihiko; Ohshima, Taichi

    1997-08-01

    Gd-DTPA can be used as a negative contrast agent on T2-weighted images because of T2 shortening effect. Fast asymmetric spin echo (FASE) sequences were used on magnetic resonance cholangiopancreatography (MRCP). Precontrast images showed high signal intensity in choledochalpancreatic venous plexus, which aggravated visualization of the bile duct and pancreatic duct. Intravenous administration of Gd-DTPA reduced signal intensity in pericholedochal or peripancreatic small veins, and improved image quality of MRCP. (author)

  13. Gd-DTPA: Clinical use in MR imaging of postoperative lumbar recurrent disk herniation and fibrosis

    International Nuclear Information System (INIS)

    Narang, A.K.; Hueftle, M.; Williams, A.; Modic, M.; Davis, D.O.

    1987-01-01

    Gd-DTPA, a paramagnetic MR contrast agent, is most familiarly utilized for delineation of brain and cord abnormalities. Since contrast-enhanced CT may help distinguish epidural fibrosis from recurrent herniated lumbar disk, the efficacy of Gd-DTPA-enhanced MR imaging was evaluated. Symptomatic patients with previous back surgery are being evaluated with pre- and post-Gd-DTPA T1- and T2-weighted images. Results to date (over 40 cases) suggest that this technique will be extremely helpful

  14. Serial magnetic resonance imaging of acute disseminated encephalomyelitis, including evaluation of the contrast-enhancing effect on lesions by Gd-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Yasunori; Matsuo, Michimasa [Tenri Hospital, Nara (Japan). MR Center

    1996-01-01

    Many papers on the MR features of acute disseminated encephalomyelitis (ADEM) have been published, but only a few described contrast-enhanced MRI for this disease. In this study, we analyzed serial changes in MR features and the contrast-enhancing effect on lesions in five patients (5 men, 4-19 years old) discharged with the final diagnosis of ADEM. Hyperintense lesions in brain/spinal cord were demonstrated on T2-weighted MR images in all cases, but not all lesions were enhanced by Gd-DTPA. In the follow-up study many lesions disappeared, but some lesions were enlarged and some new lesions were found. These findings suggest that, although ADEM is clinically monophasic, some cases may progress with the coexistence of reducing, vanishing, and new lesions. Some clinically acute lesions were not enhanced. This might be explained by the following reasons; lesions on various phases coexist, the damage to the blood-brain barrier in the lesions is of different degrees even if it is on the same phase, and the duration of acute phase activity is short. Additionally, some hyperintense lesions remained for a long time on T2-weighted images in spite of the absence of clinical manifestation. That hyperintense area might reflect edema caused by incomplete repair of the blood-brain barrier. From our evaluation of these five cases, MRI is not useful for the diagnosis and follow-up study of ADEM. (author).

  15. Time-intensity curve in the abdominal aorta on dynamic contrast-enhanced MRI with high temporal and spatial resolution. Gd-EOB-DTPA versus Gd-DTPA in vivo

    International Nuclear Information System (INIS)

    Fujinaga, Yasunari; Tsukahara, Yoshinori; Sugiyama, Yukiko; Kadoya, Masumi; Ueda, Hitoshi; Kitou, Yoshihiro

    2013-01-01

    The purpose of this study was to evaluate the difference in the time-intensity curves (TICs) of the abdominal aorta on dynamic contrast-enhanced MRI (DCE-MRI) between gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) and gadolinium ethoxybenzydiethylenetriamine pentaacetic acid (Gd-EOB-DTPA). Ten healthy volunteers underwent DCE-MRI three times with the following protocol: group A, Gd-DTPA at an injection rate of 3 ml/s; group B, Gd-EOB-DTPA, 3 ml/s; group C, Gd-EOB-DTPA, 1.5 ml/s. Signal intensities (SIs) of the abdominal aorta were measured, and the contrast enhancement ratio (CER) was calculated. Time-to-CER curves were compared among the three groups. The differences in maximum CER (CER max ) and time-to-peak of CER were analyzed. The time-to-CER curve showed a double peak pattern in group A and single-peak pattern in groups B and C. The mean time between the first and the second peak was 6.2 s. The mean CER max of each group was 4.50, 4.52 and 4.27, respectively. In group A, B and C, the mean time-to-peak was 14.6, 10.6 and 12.6 s, respectively. There was a significant difference between group A and B (P<0.01). To set up the optimal protocol for abdominal DCE-MRI, it should be noted that TIC in the Gd-DTPA and Gd-EOB-DTPA group showed different patterns, and a slower injection rate showed a less abrupt SI change in the Gd-EOB-DTPA group than in the Gd-DTPA group. (author)

  16. Gd-DTPA in the evaluation of the normal and adnormal cavernous sinus

    International Nuclear Information System (INIS)

    Marks, M.P.; Thrush, A.; Enzmann, D.

    1989-01-01

    This paper reports on Gd-DTPA used in the evaluation of normal and abnormal cavernous sinus anatomy. Twenty-five normal subjects and 11 patients with cavernous sinus invasion were studied before Gd-DTPA enhancement. Normal studies were assessed for the conspicuity of the dural margins, the trigeminal cistern, and intracavernous and exiting cranial nerves. Contrast medium enhancement improved deductibility of the medical cavernous sinus margin (68% vs 38% on precontrast images) and intracavernous cranial nerves. Cranial nerves were inconsistently seen even on postcontrast images (cranial nerve III, 88%; v 1 , 36%, V 2 , 38%). On the abnormal images, contrast enhancement was beneficial in defining the relationship of tumor to parasellar structures, egress of tumor through bony foramina, and compression of the trigeminal cistern

  17. Gd-DTPA MR imaging enhancement of spinal cord tumors

    International Nuclear Information System (INIS)

    Dillon, W.P.; Bolla, K.; Mark, A.S.; Tsudura, J.S.; Norman, D.; Newton, T.H.

    1987-01-01

    Nineteen patients with suspected spinal cord tumors were imaged with T1- and T2-weighted sequences before and after the administration of Gd-DTPA (0.1 mmol/kg). Eleven of the 19 patients had spinal cord tumors (three unproven). Eight of 11 patients had intramedullary tumors (four astrocytomas, two ependymomas) and two had extra-medullary tumors (one meningioma, one metastatic melanoma). Other lesions studied include idiopathic syringomyelia (two), spinal arteriovenous malformation (AVM) (one), posttraumatic arachnoiditis (one), and cord infarct (one). All of the tumors enhanced after the administration of Gd-DTPA. Spinal cord enhancement was also noted in association with a spinal cord AVM, a suspected cord infarct, and in the patient with severe arachnoiditis. No enhancement was present in patients with idiopathic or posttraumatic syringomyelia or in the three normal patients. In six of the patients, enhancement was critical in confirming disease that was questionable on the precontrast MR images. Gadolinium enhancement allowed differentiation of tumor from postoperative changes in two patients with spinal cord tumors. Enhanced images localized the lesion more accurately than precontrast MR images in eight patients. In four patients a lesion could only be detected after the administration of contrast. The postcontrast images better defined the margin of tumor from surrounding edema, operative scarring, and cord cavitation. The AVM case had enhancement of slowly flowing veins with Gd-DTPA posterior to an ischemic cord segment. Gd-DTPA enhancement is extremely useful in the detection and therapeutic assessment of spinal cord tumors; however, enhancement is not specific for tumors and should be interpreted in light of the clinical setting

  18. MR imaging of the breast with Gd-DTPA enhancement

    International Nuclear Information System (INIS)

    Hachiya, Junichi; Seki, Tsuneaki; Okada, Minoru; Nitatori, Toshiaki; Korenaga, Tateo; Furuya, Yoshiro

    1991-01-01

    The accuracy of MR imaging with Gd-DTPA enhancement was compared with mammography and ultrasonography in 52 patients with clinically palpable benign and malignant breast masses (36 carcinomas, 2 malignant phyllodes tumors, 7 fibroadenomas, 7 cysts). On dynamic MR imaging, carcinomas and fibroadenomas were discriminated by their different dynamic enhancement profiles. In carcinomas, signal intensity increased rapidly, reaching a peak or plateau within 2 min after the injection of contrast medium. In fibroadenomas, signal intensity showed a much slower continuous increase without ceasing until about 8 min after injection. Malignant phyllodes tumors showed a dynamic enhancement profile identical to that of benign fibroadenomas. MR imaging correctly identified 84% of malignant tumors, 86% of fibroadenomas, and 100% of cysts, and was substantially more accurate in tissue characterization than mammography. The results of ultrasonography were highly similar to those of MR imaging. However, no single modality was infallible, and the three modalities were complementary rather than competitive. Considering the high cost and long examination time of MR imaging, mammography supplemented by ultrasonography seems to be the method of choice in the diagnosis of breast lesions. Nevertheless, MR imaging can add important information when the results of mammography and ultrasonography are insufficient or contradictory. (author)

  19. MR imaging of the central nervous system in infants and children with Gd-DTPA

    International Nuclear Information System (INIS)

    Baierl, P.; Bauer, W.M.; Forster, C.; Haustein, J.

    1988-01-01

    Twenty-five infants and children (aged 2 - 12 years) were examined with MR imaging at 1.0 T. Most of them were younger than 6 years, and general anesthesia was required for the recording of the images. Gd-DTPA was given in doses of 0.1 mmol/kg (Schering). The native MR images were followed by short flip-angle sequences (fast low-angle shot [FLASH] during the flow of Gd-DTPA. After that, T1-weighted images demonstrated contrast enhancement best. No severe adverse effects were seen. The sensitivity of plain MR imaging could not be improved by Gd-DTPA, but contrast enhancement of a lesion proved to be important for the differential diagnosis

  20. Gd-DTPA-enhanced MR imaging of avascular necrosis of the hip

    International Nuclear Information System (INIS)

    Van de Berg, B.; Malghem, J.; Noel, H.; Maldague, B.

    1990-01-01

    This paper evaluates the interest of Gd-DTPA-enhanced MR imaging in the diagnosis of avascular necrosis (AVN) of the hip. MR imaging of 10 patients with various stages of AVN of the femoral head (14 abnormal hips) was performed (1.5-T Gyroscan). T1-weighted images before and after contrast injection and T2-weighted images were obtained in two planes. MR images were compared with pathologic findings in six femoral head specimens (total hip replacement). In the early stages of AVN (Mitchell classes A and B), a peripheral band of contrast-enhanced tissue appears on T1-weighted images after Gd-DTPA injection, mimicking the double line seen on T2-weighted images. In later stages (class C and D), the sequestrated segments, appearing hypointense on T1-weighted images, usually show a significant signal intensity enhancement after Gd-DTPA injection. The truly avascular areas may be limited to a band of thickened subchondral bone

  1. Does Gd-DTPA help in separating tumor from syrinx or cyst in the spinal cord

    International Nuclear Information System (INIS)

    Slasky, B.S.; Niendorf, H.P.; Steiner, R.E.; Bydder, G.M.; Young, I.R.

    1987-01-01

    There is some difficulty in differentiating among syringomyelia, syringomyelia in association with tumor, and cystic tumor in the spinal cord with MR imaging. The role of the paramagnetic contrast agent Gd-DTPA in evaluating this problem was studied in 16 patients. Contrast enhancement was observed in all 12 patients with histologically proved tumors. Enhancement was marked in eight cases, moderate in two cases, and mild in two cases. Compared to the unenhanced images, the images obtained after Gd-DTPA administration delineated more clearly and accurately the exact location and extent of tumor in cord cavitation. This information was extremely helpful in biopsy, definitive surgery, and radiation therapy

  2. Phantom and animal studies of a new hepatobiliary agent for MR imaging: comparison of Gd-DTPA-DeA with Gd-EOB-DTPA.

    Science.gov (United States)

    Yoshikawa, Kohki; Inoue, Yusuke; Akahane, Masaaki; Shimada, Morio; Itoh, Sayaka; Seno, Atsushi; Hayashi, Sanshin

    2003-08-01

    To investigate the characteristics of Gd-DTPA-DeA as a hepatobiliary contrast agent for MR imaging in comparison with those of Gd-EOB-DTPA. We undertook phantom experiments to assess T1 relaxivity for Gd-DTPA-DeA, Gd-EOB-DTPA, and Gd-DTPA in human plasma. For Gd-DTPA-DeA and Gd-EOB-DTPA, we evaluated the contrast effect in rats using an SPGR sequence. The contrast ratios of liver and abdominal aorta were measured up to 21 minutes after intravenous administration of the agents. Visualization of the bile duct and renal pelvis was also assessed. In human plasma, T1 relaxivity was similar for Gd-DTPA-DeA and Gd-EOB-DTPA, and higher than those for Gd-DTPA. Whereas the contrast ratio of liver peaked about five minutes after the injection of Gd-EOB-DTPA and was followed by a subsequent decline, a continuous rise was shown for Gd-DTPA-DeA, resulting in a larger maximal contrast effect. Contrast ratios of the abdominal aorta were larger for Gd-DTPA-DeA. Biliary excretion was observed for both agents but occurred earlier with Gd-EOB-DTPA. While renal excretion was shown for all rats three minutes after the injection of Gd-EOB-DTPA, it was not observed for Gd-DTPA-DeA. Gd-DTPA-DeA may be used as a hepatobiliary contrast agent and shows different pharmacokinetics from Gd-EOB-DTPA. Copyright 2003 Wiley-Liss, Inc.

  3. Sequential MR images of uterus after Gd-DTPA injection

    International Nuclear Information System (INIS)

    Okada, Susumu; Kato, Tomoyasu; Yamada, Keiko; Sawano, Seishi; Yamashita, Takashi; Hirai, Yasuo; Hasumi, Katsuhiko

    1993-01-01

    To investigate the sequential changes in signal intensity (SI) of normal and abnormal uteri, T1-weighted images were taken repeatedly after the injection of Gd-diethylenetriaminepentaacetic acid (DTPA). Six volunteers and 19 patients with known uterine body malignancy (18 carcinomas, one carcinosarcoma) were examined. The results in volunteers were as follows. In the secretory phase, SI of the endometrium was stronger in the late images than in the early ones, whereas in the proliferative phase, SI was stronger in the early images. SI of the myometrium decreased rapidly and there were no differences in SI between menstrual phases. In 17 of 18 endometrial carcinomas, the tumors showed hypointensity relative to the myometrium, and the contrast between the tumor and the myometrium was better in the early images. In the remaining two cases, the tumor showed hyperintensity and the contrast was better in the late images. After the injection of Gd-DTPA, the endometrium appeared differently according to the menstrual cycle in normal volunteers, and the appearance of uterine structures and endometrial malignant tumors changed sequentially. These findings must be kept in mind when evaluating uterine diseases by Gd-DTPA enhanced MRI. (author)

  4. Gd-DTPA-enhanced MR in thoracic disc herniations

    Energy Technology Data Exchange (ETDEWEB)

    Parizel, P.M.; Rodesch, G.; Baleriaux, D.; Segebarth, C.; Zegers de Beyl, D.; Haens, J. d' ; Noterman, J.

    1989-03-01

    The Gd-DTPA-enhanced magnetic resonance findings in two patients with herniated thoracic intervertebral discs are reported. The first patient was a 56-year-old woman with a small subligamentous T6-7 disc herniation, slightly lateralized to the right. The second patient was a 51-year-old man with a central and right posterolateral disc herniation, including a large calcified fragment, at the T8-9 level. The nonenhanced MR examination revealed the presence of an extradural mass lesion in both patients, impinging upon the dural sac and compressing and displacing the spinal cord posteriorly. The lesion was slightly hypointense on both T1- and T2-weighted spin echo sequences. Following intravenous injection of Gd-DTPA in a dosage of 0.1 mmol/kg body weight, enhancement of the posterior longitudinal ligament was noted and triangular areas of contrast uptake were seen to occur in the epidural space above and below the herniated disc. At surgery, they were found to correspond to dilated and congested epidural veins.

  5. Functional dynamic MR imaging and pharmacokinetics of Gd-DTPA in patients with renal failure

    International Nuclear Information System (INIS)

    Krestin, G.P.; Neufang, K.F.R.; Friedmann, G.; Clauss, W.; Schuhmann-Giampieri, G.; Stoeckl, B.

    1989-01-01

    This paper reports excretion of Gd-DTPA analyzed in 20 patients with renal parenchymal disease and decreased creatinine clearance (20-80 mL/min) and compared with excretion in five patients with normal renal function. All 25 underwent a dynamic MR study that employed fast gradient-echo sequences with single images during breath holding. The time between appearance of the contrast agent in the renal cortex and signal intensity drop in the medulla was an indicator of glomerular filtration rate and correlated well with creatinine clearance values. Fractionate urine collection and serum analysis up to 120 hours showed a prolonged but complete (98%) elimination of Gd-DTPA. Renal functional parameters did not change after administration of Gd-DTPA, and no nephrotoxic effects were observed. Thus, MR imaging provides a good quantitative evaluation of the glomerular filtration rate; moreover, administration of Gd-DTPA in patients with renal failure does not impair excretory function and can therefore be safely applied in patients with reduced excretory function

  6. Gd-DTPA-enhanced MR imaging in facial nerve paralysis

    International Nuclear Information System (INIS)

    Tien, R.D.; Dillon, W.P.

    1989-01-01

    GD-DTPA-enhanced MR imaging was used to evaluate 11 patients with facial nerve paralysis (five acute idiopathic facial palsy (Bell palsy), three chronic recurrent facial palsy, one acute facial palsy after local radiation therapy, one chronic facial dyskinesia, and one facial neuroma). In eight of 11 patients, there was marked enhancement of the infratemporal facial nerve from the labyrinthine segment to the stylomastoid foramen. Two patients had additional contrast enhancement in the internal auditory canal segment. In one patient, enhancement persisted (but to a lesser degree) 8 weeks after symptoms had resolved. In one patient, no enhancement was seen 15 months after resolution of Bell palsy. The facial neuroma was seen as a focal nodular enhancement in the mastoid segment of the facial nerve

  7. Differentiation of hypertensive heart disease with hypertrophy and hepertrophic cardiomyopathy using consecutive time-course images of Gd-DTPA enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Ochiai, Kouichi; Isibashi, Yutaka; Shimada, Toshio; Tsukihashi, Hironori; Sato, Hidetoshi; Kitamura, Jun; Morioka, Shigefumi; Kawamitsu, Hideaki; Sugimura, Kazuro [Shimane Medical Univ., Izumo, Shimane (Japan)

    1996-03-01

    We used consecutive time-course Gd-DTPA contrast magnetic resonance images to differentiate hypertrophic cardiomyopathy (HCM) from hypertensive heart disease with hypertrophy (HHD). Seventeen patients with HCM, 6 patients with HHD and 5 normal subjects (control) were studied. ECG-gated MRI with 1.5T system was performed before and after intravenous injection of Gd-DTPA (0.1mmol/Kg) using spin echo sequence. Gd-DTPA enhanced MRI was repeated every 10 to 55 minutes. We measured signal intensity (SI) of midleft ventricular myocardium and skeletal muscle, and then calculated the ratio between myocardial SI and skeletal muscle SI. Myocardium was enhanced by Gd-DTPA in all patients. However, there was difference in the decay of enhancement effect by Gd-DTPA between HCM and HHD. The decay in HCM was more slowly than in both HHD and control. There was no difference in the decay between HHD and control. The difference in the decay between HCM and HHD became significant 25 minutes after Gd-DTPA injection and lasted until 55 minutes. We conclude that the time-course of the decay of enhancement effect by Gd-DTPA is helpful to differentiate HCM from HHD and the difference of the decay might reflect structural changes of myocardium. (author).

  8. The exploratory development of A self-made oral Gd-DTPA solution for low field MRCP in children

    International Nuclear Information System (INIS)

    Sheng Mao; Zhou Min; Gu Zhicheng; Wu Jizhi; Guo Wanliang; Ni Yongbiao; Fang Lin

    2010-01-01

    Objective: To evaluate the value of ingestion self-made Gd-DTPA solutin for low field magnetic resonance cholangiopancreatography (MRCP) (0.35T) in children. Methods: Phantom experiments were performed to select the optimal concentration of Gd-DTPA to be used as an oral negative contrast agent in low field MRCP. Twenty children suspected of celiac disease were performed with MRCP before and after ingestion Gd-DTPA solution. Signal intensity measurements of gastroduodenal lumens, pancreatobiliary ducts, and image quality scores were obtained systematically before and after contrast ingestion. Results: The selected Gd-DTPA concentration was 1.992 mmol/L. Ingestion of 80 ml solution eliminated or suppressed efficiently the gastroduodenal signal intensity, improving the MRCP image quality scores (P<0.01) significantly in children. Conclusion: 1.992 mmol/L self-made Gd-DTPA solutin can suppress or eliminate water signals from gastrointestinal tract and improve the quality of low field MRCP image in children. (authors)

  9. MR imaging of the cochlear modiolus after intratympanic administration of Gd-DTPA

    International Nuclear Information System (INIS)

    Kawai, Hisashi; Naganawa, Shinji; Ishihara, Shunichi; Sone, Michihiko; Nakashima, Tsutomu

    2010-01-01

    We evaluated whether enhancement of the cochlear modiolus could be visualized 24 hours after intratympanic injection of gadolinium diethylenetriamine penta-acetic acid (Gd-DTPA) using a 3-dimensional real inversion recovery sequence combined with a 32-channel head coil at 3 tesla. Intratympanic injection of Gd-DTPA has been reported for visualizing endolymphatic hydrops in Meniere's disease, and its use has shown communication between the cochlear perilymph and cerebrospinal fluid in the internal auditory canal. Although the cochlear modiolus has been considered the route for this communication, this has not been confirmed through direct visualization of its enhancement. We qualitatively and quantitatively evaluated the presence of contrast enhancement in the modiolus in 19 patients with clinically suspected endolymphatic hydrops or hearing loss who underwent imaging as described above. The contrast ratio (CR) between the cochlear modiolus and cerebellar white matter on the injected side was 1.09±1.23, and that on the non-injected side was -0.48±0.38 (P<0.01). In all subjects, the CR value was larger on the injected than non-injected side, and enhancement of the cochlear modiolus was also recognized visually. Intratympanic Gd-DTPA can be administered to visualize enhancement of the cochlear modiolus and may thereby reveal its functional anatomy. (author)

  10. Absolute renal blood flow quantification by dynamic MRI and Gd-DTPA

    International Nuclear Information System (INIS)

    Vallee, J.P.; Lazeyras, F.; Khan, H.G.; Terrier, F.

    2000-01-01

    The aim of this study was to demonstrate the feasibility of the absolute renal blood flow quantification using MRI and injection of contrast media. Using a T1-weighted fast gradient sequence following an intravenous bolus injection of Gd-DTPA, dynamic images of the kidney were obtained in patients with well-functioning native kidneys (n=7) or transplant (n=9), with significant renal artery stenosis (n=4) and with renal failure (n=7). After signal intensity calibration, the absolute renal perfusion was equal to the wash-in slope of the renal transit curve divided by the contrast medium concentration at the peak of the bolus in the aorta. The cortical blood flow was 2.54±1.16 ml/min per gram in well-functioning kidneys decreasing to 1.09±0.75 ml/min per gram in case of renal artery stenosis (p=0.04) and to 0.51 ± 0.34 ml/min per gram in case of renal failure (p<0.001). These measurements were in agreement with previous results obtained by other methods. A standard MRI imaging sequence and a simple model can provide realistic quantitative data on renal perfusion. This work justifies further studies to compare this model with a gold standard for renal blood flow measurements. (orig.)

  11. Behavior of Gd-DTPA in simulated bank filtration

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Peter, E-mail: pemoe@gfz-potsdam.de [Freie Universitaet Berlin, Malteserstr. 74-100, AB Hydrogeologie, 12249 Berlin (Germany)] [Helmholtz Zentrum Potsdam, Deutsches GeoForschungsZentrum, Telegrafenberg, 14473 Potsdam (Germany); Knappe, Andrea [Freie Universitaet Berlin, Malteserstr. 74-100, AB Hydrogeologie, 12249 Berlin (Germany); Dulski, Peter [Helmholtz Zentrum Potsdam, Deutsches GeoForschungsZentrum, Telegrafenberg, 14473 Potsdam (Germany); Pekdeger, Asaf [Freie Universitaet Berlin, Malteserstr. 74-100, AB Hydrogeologie, 12249 Berlin (Germany)

    2011-01-15

    Research highlights: {yields} Gd-DTPA and similar products are common pollutants in surface and groundwater and prove to be a reliable monitor for mixing of groundwater with surface water loaded with effluents from sewage treatment plants. {yields} Within a 30 m column filled with Pleistocene sand Gd-DTPA is reduced by 16% only within one month time by transmetallation. {yields} Artificial bank filtration is not very effective in reducing Gd-DTPA in infiltrating water. - Abstract: The behavior of Gd-DTPA during bank filtration was simulated in a 30 m column filled with Pleistocene sand and flushed by surface water from a lakeside in Berlin, Germany. The surface water is about a 1:1 mixture of river water and effluents from a sewage treatment plant. Throughout 34 days this water was continuously spiked with Gd-DTPA at a level of 60 {mu}g/L. The broad plateau of the Gd-DTPA pulse declined by 15.4% within 34 days by transmetallation. Nine percentage of the total decline is caused by Y and rare earth elements; the remaining part is attributed to Cu{sup 2+} which is the most influential metal in surface water. All other metals also contributing to transmetallation are combined with Cu to Cu equivalents because only the rate constant of transmetallation of Cu{sup 2+} is known. The analytical results of the column effluents prove the pseudo-first-order kinetics of transmetallation based on reversible sorption of metals by pools in the column sediment and disprove biodegradation at noticeable levels. The mass ratio of water to tracer is <10{sup 10}.

  12. MR cisternography after intrathecal Gd-DTPA application

    International Nuclear Information System (INIS)

    Reiche, Werner; Komenda, Yvonne; Steudel, Wolf-Ingo; Schick, Bernhard; Grunwald, Iris; Reith, Wolfgang

    2002-01-01

    The purpose of this study was to establish and to evaluate MR cisternography after intrathecal Gd-DTPA administration to detect rhinobasal cerebrospinal fluid (CSF) fistulae in patients with suspected CSF rhinorrhoea. Ten patients with suspected CSF rhinorrhoea were examined. The MR cisternography included the following investigation steps: acquisition of nonenhanced fat-suppressed T1-weighted spin-echo (SE) scans of the skull base and the paranasal sinuses, lumbar puncture with administration of 1 ml Gd-DTPA solute with 4 ml NaCl and performance of MR cisternography with the same fat-suppressed T1-weighted sequences as used initially. In 10 patients with suspected CSF rhinorrhoea Gd-DTPA enhanced MR cisternography detected 5 CSF fistulae. In 3 of 5 CSF leaks were located in the cribriform plate and in 2 of 5 sphenoidal. Whereas 4 of these depicted leaks were confirmed surgically, in 1 case the CSF fistula closed spontaneously. In another case, CSF leakage after severe head injury was clinically highly suspected but ceased prior to MR cisternography with inability to detect the temporary fistula. In the remaining 4 patients with serous rhinorrhoea MR cisternography did not provide any evidences for CSF fistulae. Intrathecal Gd-DTPA injection was tolerated excellently. Clinical and EEG examinations showed no gross behavioural or neurological disturbances and no seizure activity, respectively. The MR cisternography after intrathecal administration of Gd-DTPA represents a safe, promising and minimally invasive method for detection of CSF fistulae. This MR investigation provides excellent depiction of CSF spaces and pinpoints CSF fistulae. (orig.)

  13. Intraindividual comparison of T1 relaxation times after gadobutrol and Gd-DTPA administration for cardiac late enhancement imaging

    Energy Technology Data Exchange (ETDEWEB)

    Doeblin, Patrick, E-mail: Patrick.doeblin@charite.de [Department of Cardiology, Charité – Universitätsmedizin Berlin, Charité Campus Benjamin Franklin, Berlin (Germany); Schilling, Rene, E-mail: rene.schilling@charite.de [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); Wagner, Moritz, E-mail: moritz.wagner@charite.de [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); Luhur, Reny, E-mail: renyluhur@yahoo.com [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); Huppertz, Alexander, E-mail: alexander.huppertz@charite.de [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); Imaging Science Institute, Charité, Berlin (Germany); Hamm, Bernd, E-mail: bernd.hamm@charite.de [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); Taupitz, Matthias, E-mail: matthias.taupitz@harite.de [Department of Radiology, Charité – Universitätsmedizin Berlin, Charité Campus Mitte, Berlin (Germany); and others

    2014-04-15

    Purpose: To evaluate T1-relaxation times of chronic myocardial infarction (CMI) using gadobutrol and gadopentetate dimeglumine (Gd-DTPA) over time and to determine the optimal imaging window for late enhancement imaging with both contrast agents. Material and methods: Twelve patients with CMI were prospectively included and examined on a 1.5 T magnetic resonance (MR) system using relaxivity-adjusted doses of gadobutrol (0.15 mmol/kg) and Gd-DTPA (0.2 mmol/kg) in random order. T1-relaxation times of remote myocardium (RM), infarcted myocardium (IM), and left ventricular cavity (LVC) were assessed from short-axis TI scout imaging using the Look–Locker approach and compared intraindividually using a Wilcoxon paired signed-rank test (α < 0.05). Results: Within 3 min of contrast agent administration (CA), IM showed significantly lower T1-relaxation times than RM with both contrast agents, indicating beginning cardiac late enhancement. Differences between gadobutrol and Gd-DTPA in T1-relaxation times of IM and RM were statistically not significant through all time points. However, gadobutrol led to significantly higher T1-relaxation times of LVC than Gd-DTPA from 6 to 9 min (220 ± 15 ms vs. 195 ± 30 ms p < 0.01) onwards, resulting in a significantly greater ΔT1 of IM to LVC at 9–12 min (−20 ± 35 ms vs. 0 ± 35 ms, p < 0.05) and 12–15 min (−25 ± 45 ms vs. −10 ± 60 ms, p < 0.05). Using Gd-DTPA, comparable ΔT1 values were reached only after 25–35 min. Conclusion: This study indicates good delineation of IM to RM with both contrast agents as early as 3 min after administration. However, we found significant differences in T1 relaxation times with greater ΔT1 IM–LVC using 0.15 mmol/kg gadobutrol compared to 0.20 mmol/kg Gd-DTPA after 9–15 min post-CA suggesting earlier differentiability of IM and LVC using gadobutrol.

  14. Efficacy of Gd-DTPA-enhanced MRI in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Okamoto, Shinya; Aoki, Toshikazu; Konishi, Tokuji; Nakano, Takeshi; Yamakado, Kyoichiro; Sakuma, Hajime; Takeda, Kann; Nakagawa, Takashi

    1991-01-01

    The cabability of magnetic resonance (MR) imaging to detect tissue characterization or myocardial degeneration process of the hypertrophied myocardium was evaluated in 15 patients with hypertrophic cardiomyopathy. T1-weighted MR images were obtained with a 1.5 T MR unit by using ECG-gated spin-echo techniques. MR images were visually reviewed before and after enhancement of Gd-DTPA. Four patients had an increase in signal intensity mainly in the endocardium of the left ventricular septum on non-enhanced MR images, 3 of whom had widespread high intensity in addition to two-thirds of the wall. Gd-DTPA enhanced-MR images showed high intensity over the whole septum in 5 patients and also in the antero-lateral endocardium in 4 patients. Decreased intensity on non-enhanced MR images, as shown in 4 patients, became clear on enhanced-MR images. According to findings on enhanced-MR images, signal intensity was defined as normal (N), septum (S), and diffuse (D). Patients in Group D tended to be younger and have more frequently family history. Regarding both interventricular septum thickness and left ventricular posterior wall thickness, there was no significant difference among the three groups. Both left ventricular diastolic diameter and left ventricular systolic diameter were significantly larger in Group D than the other two groups. Left ventricular ejection fraction was significantly lower in both Group S and Group D. Widespread abnormal intensity on Gd-DTPA enhanced MR images was associated with findings similar to dilated cardiomyopathy, such as dilated left ventricular lumen and decreased ejection fraction. Gd-DTPA enhanced MR imaging seemed to be useful for visualizing myocardial degeneration in hypertrophic cardiomyopathy.(N.K.)

  15. Intracoronary delivery of Gd-DTPA and Gadophrin-2 for determination of myocardial viability with MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Y.; Bosmans, H.; Miao, Y.; Bogaert, J.; Dymarkowski, S.; Yu, J.; Baert, A.L.; Marchal, G. [Dept. of Radiology, University Hospitals, Catholic University Leuven (Belgium); Pislaru, C.; Pislaru, S.; Werf, F. van de [Dept. of Cardiology, University Hospitals, Catholic University Leuven (Belgium); Semmler, W. [Inst. fuer Diagnostikforschung GmbH, Berlin (Germany)

    2001-05-01

    The aim of this study was to compare intracoronary (i. c.) administration of Gadophrin-2, a necrosis-avid contrast agent (NACA), and nonspecific agent Gd-DTPA for determination of myocardial viability (MV) in acute myocardial infarction (AMI) with MRI. Reperfused AMI was induced in 12 dogs by transcatheter balloon occlusion of coronary artery. In 6 dogs each, Gd-DTPA at 0.1 mmol/kg or Gadophrin-2 at 0.005 mmol/kg was administered into coronary artery by fast bolus (n = 3) or slow infusion (n = 3). Serial ECG-triggered cardiac MRI of T1-weighted segmented turbo fast low-angle shot (FLASH) sequence was conducted and compared with triphenyltetrazolium chloride (TTC) histochemical staining. The contrast ratio and infarct size were quantified and analysed statistically. No cardiovascular side effects were found with local delivery of both agents. After i. c. administration, Gadophrin-2 induced a strong (CR {>=} 1.78) and persistent ({>=} 10 h) contrast enhancement of infarcted region. The infarct size defined with Gadophrin-2 was almost identical to that with TTC staining throughout the postcontrast period. With a dose 20 times higher, Gd-DTPA also strongly enhanced infarct-to-normal contrast; however, the enhancement diminished with time, i. e. from early strong to later faint enhancement and eventual loss of contrast. The delineated infarct size was also unstable, i. e. from early overestimation to later underestimation and eventual disappearance of the enhanced infarct. In combination with PTCA procedure, i. c. administration of MRI contrast agents may prove useful for post-procedure verification of diagnosis. The NACA-enhanced MRI may serve as an in vivo surrogate of postmortem histochemical staining for determination of MV. Although applicable in clinical setting, cardiac MRI with nonspecific Gd-DTPA is less reliable and should be performed within less than 1 h after contrast. (orig.)

  16. Hemophilic arthropathy of the knee joint: static and dynamic Gd-DTPA - enhanced MRI

    Energy Technology Data Exchange (ETDEWEB)

    Naegele, M. [Dept. of Radiology, Univ. Bonn (Germany); Bruening, R. [Dept. of Radiology, Univ. Muenchen (Germany); Kunze, V. [Dept. of Radiology, Univ. Bonn (Germany); Eickhoff, H. [Dept. of Orthopedic Surgery, Troisdorf (Germany); Koch, W. [Dept. of Orthopedic Surgery, Troisdorf (Germany); Reiser, M. [Dept. of Radiology, Univ. Muenchen (Germany)

    1995-12-31

    A total of 17 patients with hemophilic arthropathy of the knee joint were studied with static and dynamic MRI before and after an IV bolus injection of Gadolinium-DTPA (Gd-DTPA; 0.1 mmol/kg body weight). The T1-weighted spin-echo (SE) and gradient-echo (fast-field echo [FFE]) sequences were applied. The FFE sequences of eight consecutive scans carried out over a time interval of 160 s were used in order to determine the time to signal intensity (SI) curves of the synovial proliferations surrounding soft tissue, bone marrow, and joint effusion. After the administration of a contrast agent, synovial proliferations exhibited an increase on FFE and SE images of 47.7% (SD {+-} 14.3%) and 37.4% (SD {+-} 11.2%), respectively, whereas muscle and fatty tissue, tendons, bone marrow, and joint effusion revealed only a minor increase in SI. The gradient of SI (ratio SI/time) of pannus was 39.6%/min (SD {+-} 7.7%/min) and differed significantly (P < 0.001) from that of bone marrow, fatty tissue, muscle tissue, tendons, and joint effusion (P < 0.05). In contrast to synovial proliferations in rheumatoid arthritis, no differentiation between various pannus vascularities based on the degree of enhancement was possible. The Gd-DTPA-enhanced MRI studies delineate and quantify the synovial proliferations in hemophilic arthropathy. Dynamic studies in hemophilic arthropathy do not provide qualitative assessment of the inflammatory process. (orig.)

  17. Pharmacokinetic analysis of Gd-DTPA enhancement in dynamic MR of breast carcinoma. Pharmakokinetische Analyse der Gd-DTPA-Anreicherung in der MRT beim Mammakarzinom

    Energy Technology Data Exchange (ETDEWEB)

    Hess, T. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie); Knopp, M.V. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie); Hoffmann, U. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie); Brix, G. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie); Junkermann, H. (Heidelberg Univ. (Germany). Abteilung fuer Gynaekologische Radiologie); Zuna, I. (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie); Fournier, D. von (Heidelberg Univ. (Germany). Abteilung fuer Gynaekologische Radiologie); Kaick, G. van (Deutsches Krebsforschungszentrum, Heidelberg (Germany). Forschungsschwerpunkt Radiologische Diagnostik und Therapie)

    1994-06-01

    Dynamic Gd-DTPA enhanced MR of the breast was performed in one single slice in 27 patients with suspicious nodular lesions. The results could be histologically verified in all cases. A rapid spin-echo sequence with a time resolution of 8.75 s was used for the dynamic examination. The signal changes were analysed using a pharmacokinetic model which allowed parametrization of the contrast enhancement and transformation of the data into colour coded parameter images. The parameters allowed reliable distinction of 9 benign from 18 malignant lesions (p<0.05 for ''amplitude'', p<0.001 for ''k[sub 21]''). One fibroadenoma could not be distinguished from the carcinomas. Lymph node metastases and the pharmacokinetic parameter amplitude correlated significantly (p<0.05). (orig.)

  18. Functional cardiac MR imaging with true fast imaging with steady-state free precession before and after intravenous injection of contrast medium: comparison of image quality and accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Krombach, Gabriele A. [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); University Hospital Giessen, Department of Radiology, Justus-Liebig University Giessen, Giessen (Germany); Plum, Thorsten; Kraemer, Nils A.; Guenther, Rolf W.; Schoth, Felix [University Hospital, RWTH Aachen, Department of Diagnostic Radiology, Aachen (Germany); Koos, Ralf; Hoffmann, Rainer; Altiok, Ertunc [University Hospital, RWTH Aachen, Department of Cardiology, Aachen (Germany)

    2011-04-15

    To compare image quality and accuracy of left ventricular function of cine SSFP (steady-state free precession) images before and after injection of Gd-DTPA. In 30 patients T1 times of LV blood and myocardium were measured before and after injection of 0.2 mmol/kg body weight Gd-DTPA. Signal intensity of myocardium and left ventricular blood were measured on SSFP images and the contrast calculated. In 20 additional patients short axis images completely covering the left ventricle were acquired before and after injection of Gd-DTPA and parameters of left ventricular function compared. Image quality and regional function were assessed using the 17-segment model. Image quality after injection of contrast medium did not significantly change compared with unenhanced images. Contrast between myocardium and LV blood decreased from 0.6 {+-} 0.01 to 0.4 {+-} 0.03 after injection while the T1 value of myocardium decreased from 1121 {+-} 21 ms to 389 {+-} 14 ms (blood 1413 {+-} 48 ms to 222 {+-} 8 ms). Assessment of regional and global left ventricular function revealed similar results before and after the injection of contrast medium. Cine SSFP can be obtained after injection of contrast medium without loss of accuracy for regional and global LV ventricular function. This protocol can be used to decrease imaging time for thorough cardiac examination. (orig.)

  19. Biliary enhanced MR imaging by Gd-DTPA

    International Nuclear Information System (INIS)

    Ohkawa, Shinichi; Fujikura, Yuji; Kanai, Toshio; Hiramatsu, Kyoichi.

    1992-01-01

    Biliary enhanced MRI (BEMRI) by Gd-DTPA via PTCD and/or PTGBD tube for obstructive jaundice was performed in 8 patients. In all cases, biliary tract was clearly visualised as high signal intensity on T1 weighted images. On same images, primary lesion such as common bile duct cancer was also visualised as well as portal system. In addition, MR angiography (MRA) by 2D-time of flight method was performed. MRA with BEMRI shows portal encasement on the same image as biliary tract obstruction. This suggests MRA with BEMRI may replace the other modality for obstructive jaundice. (author)

  20. Enrichment of rare-earth elements (REE) and Gd-DTPA in surface water samples by means of countercurrent chromatography (CCC)

    International Nuclear Information System (INIS)

    Hennebrueder, Kristina; Engewald, Werner; Staerk, Hans-Joachim; Wennrich, Rainer

    2005-01-01

    An analytical scheme was developed for the determination of rare-earth elements and gadolinium diethylenetriaminepentaacetate (Gd-DTPA) in river water by ICP-MS. Since the concentration of Gd-DTPA and the rare-earth elements in river water is often lower than the limits of detection in quadrupole ICP-MS applying pneumatic nebulization, a preconcentration procedure is essential. In this work, the capabilities of countercurrent chromatography (CCC) for preconcentration of REE were investigated. For preconcentration ethylhexylphosphates as stationary phase had been used. Acidified aqueous samples (pH 2) and river water spiked with REE and Gd-DTPA were under study. The procedure was compared with solid phase extraction (SPE) using the same samples and ethylhexylphosphates as stationary phase. The recovery of the light and middle REE was found to be at about 100%, which was found to be more efficient than applying SPE. In contrast, the recovery rates for Yb and Lu were low (and poorly reproducible) using CCC (57% and 73%, respectively) while significant better results were obtained with SPE (89% and 84%, respectively). The recoveries of Gd applying Gd-DTPA were 80 ± 4% in the investigation of river water samples

  1. Evaluation of meningeal enhancement with Gd-DTPA

    International Nuclear Information System (INIS)

    Phillips, M.; Ryals, T.J.; Yuh, W.T.C.; Kambho, S.

    1989-01-01

    Forty-three consecutive patients (16 with tumor, 11 with inflammation, 16 postoperative) with abnormal meningeal enhancement were studied. Positive pathology was obtained in 75% of tumors and 100% of inflammatory conditions. Pial enhancement was demonstrated in seven of 11 patients with inflammation, four of 16 with tumor, and two of 16 postoperative patients. Diffuse meningeal enhancement was most commonly present with neoplastic and inflammatory etiologies. Localized enhancement predominated in the postoperative population, unless complicated by a subdural hematoma. A nodular appearance was present in two patients with tumor. In conclusion, Gd-DTPA MR imaging is sensitive to but not specific of meningeal pathology. MR imaging is better in inflammatory than in neoplastic conditions

  2. Gd-DTPA enhanced MR imaging in Bell's palsy

    International Nuclear Information System (INIS)

    Matsumoto, Yasushi; Kawamura, Yuji; Yanagihara, Naoaki; Sadamoto, Masanori; Sadamoto, Kazuhiko.

    1991-01-01

    Magnetic resonance imaging (MRI) was carried out in 27 patients with Bell's palsy. T1-weighted spin-echo images (TR500/TE25-34) were taken before and after the intravenous administration of Gd-DTPA (0.1 mmol/kg) with 0.5T superconductive MRI. There was significant enhancement at the geniculate ganglion and the horizontal segment of the involved facial nerve in 22 patients (81.5%) and at the vertical segment in 20 (74.1%). Enhancement at the meatal fundus was seen in only 4 patients (14.9%) and at the labyrinthine segment in 8 (29.6%). These results corroborate other evidence that the geniculate ganglion is involved most frequently in Bell's palsy. In addition, the enhancement of the proximal portion, i.e. the meatal fundus and the labyrinthine segment of the nerve, although not common, noted in this study may be important in the diagnosis and treatment of Bell's palsy. (author)

  3. MRT of scaphoid pseudo-arthrosis using Gd-DTPA. Staging and clinical correlation

    International Nuclear Information System (INIS)

    Vogl, T.J.; Beutel, F.; Wilhelm, K.; Tempka, A.; Schedel, H.; Haas, R.; Felix, R.

    1994-01-01

    During a period of two years, 134 patients with pseudo-arthrosis of the scaphoid were examined by conventional radiography and by MRI in the course of a prospective study. The aim of the study was to define radiological staging using contrast enhanced MRI in order to improve the prognostic criteria. All MRI examinations were carried out with a 1.5 Tesla scanner (SP63) using a surface coil and T 1 weighted spin echo sequences in sagittal and frontal projection and frontal FLASH T 2 -sequences and axial spin echo T 2 sequences. The T 1 weighted SE sequences in frontal projection were carried out before and after iv contrast (0.1 mmol Gd-DTPA/kg KG). All sequences were compared with conventional radiographs and the operative findings. Eight patients in stage 0 showed high signal intensity of both fragments in T 1 weighted SE sequences and at surgery there was good vascularisation. In 22 cases there was reduced signal intensity in at least one fragment (stage I). 45 patients with scaphoid pseudo-arthrosis showed complete signal loss but marked contrast uptake with still vital nuclei at surgery (stage II). In 22 patients, there was no increase in signal intensity after contrast and complete loss of vitality of the fragments at surgery. Staging was not possible in 37 patients because of previous operative intervention. The use of contrast enhanced MRI provides additional information compared with conventional radiography or plain MRI. (orig.) [de

  4. Sequential MR images of uterus after Gd-DTPA injection; Studies of normal volunteers and uterine endometrial malignant tumors

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Susumu; Kato, Tomoyasu; Yamada, Keiko; Sawano, Seishi; Yamashita, Takashi; Hirai, Yasuo; Hasumi, Katsuhiko (Japanese Foundation for Cancer Research, Tokyo (Japan). Hospital)

    1993-03-01

    To investigate the sequential changes in signal intensity (SI) of normal and abnormal uteri, T1-weighted images were taken repeatedly after the injection of Gd-diethylenetriaminepentaacetic acid (DTPA). Six volunteers and 19 patients with known uterine body malignancy (18 carcinomas, one carcinosarcoma) were examined. The results in volunteers were as follows. In the secretory phase, SI of the endometrium was stronger in the late images than in the early ones, whereas in the proliferative phase, SI was stronger in the early images. SI of the myometrium decreased rapidly and there were no differences in SI between menstrual phases. In 17 of 18 endometrial carcinomas, the tumors showed hypointensity relative to the myometrium, and the contrast between the tumor and the myometrium was better in the early images. In the remaining two cases, the tumor showed hyperintensity and the contrast was better in the late images. After the injection of Gd-DTPA, the endometrium appeared differently according to the menstrual cycle in normal volunteers, and the appearance of uterine structures and endometrial malignant tumors changed sequentially. These findings must be kept in mind when evaluating uterine diseases by Gd-DTPA enhanced MRI. (author).

  5. Communication between cochlear perilymph and cerebrospinal fluid through the cochlear modiolus visualized after intratympanic administration of Gd-DTPA

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Satake, Hiroko; Iwano, Shingo; Sone, Michihiko; Nakashima, Tsutomu

    2008-01-01

    Intratympanic injection of gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) has been reported as a procedure to visualize endolymphatic hydrops of Meniere's disease. We frequently noted that cerebrospinal fluid (CSF) in the internal auditory canal (IAC) was also enhanced after this procedure. The purpose of this study was to evaluate how frequently this occurs and to investigate the specific features of patients who lack this communication. A total of 25 patients with clinically suspected endolymphatic hydrops underwent the procedure. After 24 h, three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) and 3D constructive interference in steady state (3D-CISS) were performed. The presence of contrast enhancement in the CSF space of the fundus of the IAC was evaluated. The contrast ratio between CSF of the IAC fundus and cerebellar white matter on the injected side was 1.49±0.65, and that of the noninjected side was 0.32±0.16 (P<0.01). Enhancement of the CSF space in the IAC fundus was seen in all but two subjects: one had enlarged endolymphatic duct and sac syndrome (EEDS), and the other had cochlear nerve agenesis. In these two patients, the cochlear modiolus seemed to be normal. Intratympanic Gd-DTPA administration can reveal permeability of the modiolus and might facilitate evaluation of functional abnormalities of the modiolus not detected by conventional imaging tests. (author)

  6. MRT of scaphoid pseudo-arthrosis using Gd-DTPA. Staging and clinical correlation; MRT der Skaphoidpseudarthrose mit Gd-DTPA. Stadieneinteilung und klinische Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Beutel, F. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Wilhelm, K. [LMU Muenchen (Germany). Abt. fuer Handchirurgie; Tempka, A. [Freie Univ. Berlin (Germany). Klinik fuer Unfall- und Wiederherstellungschirurgie; Schedel, H. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Haas, R. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik; Felix, R. [Freie Univ. Berlin (Germany). Strahlenklinik und Poliklinik

    1994-11-01

    During a period of two years, 134 patients with pseudo-arthrosis of the scaphoid were examined by conventional radiography and by MRI in the course of a prospective study. The aim of the study was to define radiological staging using contrast enhanced MRI in order to improve the prognostic criteria. All MRI examinations were carried out with a 1.5 Tesla scanner (SP63) using a surface coil and T{sub 1} weighted spin echo sequences in sagittal and frontal projection and frontal FLASH T{sub 2}-sequences and axial spin echo T{sub 2} sequences. The T{sub 1} weighted SE sequences in frontal projection were carried out before and after iv contrast (0.1 mmol Gd-DTPA/kg KG). All sequences were compared with conventional radiographs and the operative findings. Eight patients in stage 0 showed high signal intensity of both fragments in T{sub 1} weighted SE sequences and at surgery there was good vascularisation. In 22 cases there was reduced signal intensity in at least one fragment (stage I). 45 patients with scaphoid pseudo-arthrosis showed complete signal loss but marked contrast uptake with still vital nuclei at surgery (stage II). In 22 patients, there was no increase in signal intensity after contrast and complete loss of vitality of the fragments at surgery. Staging was not possible in 37 patients because of previous operative intervention. The use of contrast enhanced MRI provides additional information compared with conventional radiography or plain MRI. (orig.) [Deutsch] Im Rahmen einer prospektiven Studie wurden in einem Zeitraum von 2 Jahren 134 Patienten mit einer Skaphoidpseudarthrose (SPA) vergleichend konventionell roentgenologisch und magnetresonanztomographisch untersucht. Ziel der Studie war die Erstellung einer klinisch radiologischen Stadieneinteilung mit Hilfe der kontrastverstaerkten MRT zur Verbesserung von Prognosekriterien. Alle MRT-Untersuchungen wurden an einem 1,5 Tesla-Geraet (SP63) mittels einer Oberflaechenspule unter Verwendung von T{sub 1

  7. Clinical utility of Gd-DTPA subtraction MR imaging for spinal bone metastasis

    International Nuclear Information System (INIS)

    Ando, Keiichi; Murakami, Masao; Kuroda, Yasumasa

    1993-01-01

    Based on reports that Gd-DTPA contributes to the detection of tumors, we used it in 31 cases (97 lesions) of spinal bone metastases. The result was that Gd-DTPA increased the intensity of tumors and the surrounding bone marrow to almost the same level in 53%. To show the metastases clearly, an existing subtraction command system was utilized. The technique included the pixel-by-pixel method, to obtain a Gd-DTPA T1-weighted image (T1WI) subtracted by the original T1WI. The detectability of the subtraction image was improved up to 96%, but was less than the original T1WI (99%). Because of the different imaging rationale between two methods, a means to assess the quality of diagnosis must be proposed. To check the normal background, the same kind of postprocessing was performed in 21 patients without malignancy. Gd-DTPA prefusion was highest in the paravertebral veins, moderate in muscles and epidural fat, and lowest in the spinal cord, intervertebral disk and bone cortex. Gd-DTPA enhanced subtraction MR imaging provides a new diagnostic tool to detect and to assess bone metastasis. (author)

  8. Liver hemangiona and metastasis: dynamic study with Gd-DTPA in magnetic resonance

    International Nuclear Information System (INIS)

    Ferrer, M.D.; Marti-Bonmati, L.; Martinez-Rodrigo, J.; Galant, J.

    1993-01-01

    The difference between liver hemangioma and metastases is a subject of clinical interest. Nineteen MR liver studies are presented, 10 of them correspond to hemangiomas and 9 to metastases. In all cases, intravenous gadolinium was used in dynamic slices with T1-weighted gradient echo sequences. Late uptake is studied in two lesions. One minute postinjection, the periphery appears hyperintense (more so than the fatty tissue) in 7 out of the 10 cases of hemangioma; in 4 cases, the metastases show less intense uptake than fatty tissue. From two and a half minutes on, the periphery is hyperintense (more so than the fatty tissue) in all the hemangiomas, while in 4 metastases, the periphery is hyperintense (but less so than the fatty tissue), and the rest of the metastases remain hypo-isointense. Uptake by the hemangiomas at two hours reveals the isointense lesion with the liver. In conclusion, at approximately one minute postinjection, hemangiomas show very marked and nodular uptake, with centripetal progression; the hypersignal persists in late slices. However, the metastases present variable, moderate, irregular uptake at the beginning, with no central progression and reduced contrast in the late slices at 5 minutes. In some cases, Gd-DTPA increases the diagnostic certainty, improving reliability with respect to conventional MR. (Author)

  9. Correlation between choline level and Gd-DTPA enhancement in patients with brain metastases of mammary carcinoma

    NARCIS (Netherlands)

    P.E. Sijens (Paul); P. van Dijk (Pieter); M. Oudkerk (Matthijs)

    1994-01-01

    textabstractSingle voxel 1HH double spin-echo MR spectroscopy was used to examine 15 cases of brain metastasis of mammary carcinoma (18 lesions) in relation to Gd-DTPA enhanced MR imaging. For lesions larger than 50% of MRS voxel size, there was significant correlation between Gd-DTPA-enhanced MRI

  10. Sequential Gd-DTPA-enhanced MR imaging after surgical treatment of osteonecrosis of the femoral head

    International Nuclear Information System (INIS)

    Postema, S.; Bloem, J.L.; Bloem, R.M.

    1990-01-01

    This paper evaluates the perfusion of necrotic bone and surrounding areas in osteonecrosis of the femoral head following surgical treatment with MR imaging before and after Gd-DTPA enhancement. Thirteen surgically treated hips (one Ficat stage 1, three stage 2, one stage 2-3, five stage 3, three stage 4) and four hips that were treated conservatively were studied with MR imaging before and after intravenous administration of GD-DTPA. Follow-up studies range from 7 days to 33 months

  11. Postdiscectomy lumbar MR with GD-DTPA in differentation between scar tissue and recurrent prolapse

    International Nuclear Information System (INIS)

    Majewski, A.; Pedrosa, P.; Schuth, M.; Higer, H.P.

    1989-01-01

    The non-invasive diagnostic possibilities of MR have resulted in better diagnosis of degenerative spinal diseases. Twenty-one patients with failed back surgery syndrome (postdiscectomy syndrome) were studied to evaluate the possibility of 1-Tesla magnetic resonance (MR) imaging with gadolinium diethylene triamine pentaacetic acid (Gd-DTPA) in differentiating post operative scar tissue from recurrent disc herniation. The enhanced MR studies correctly depicted the character of abnormal epidural tissue in all patients. We conclude that MR with Gd-DTPA might be the method of choice to differentiate reliably postoperative epidural fibrosis from recurrent disc prolapse. (orig.) [de

  12. Histopathological study correlated with Gd-DTPA-enhanced MR imaging in glioma

    International Nuclear Information System (INIS)

    Komatsu, Yoji; Yoshii, Yoshihiko; Nose, Tadao; Yamada, Takashi; Takano, Shingo; Kobayashi, Eiki.

    1989-01-01

    In order to clarify the histopathological correlation with Gd-DTPA-enhanced MR imaging in glioma, brain specimens from seven cases of glioblastoma multiforme, two cases of benign astrocytoma, and two cases of radiation injury were investigated. T 1 -weighted MR imagings were obtained before and after the injection of Gd-DTPA (dose: 0.1 m mol/kg). The authors classified the patterns of enhancement into four types : (1) Delineated enhanced type (a delineated and homogeneously enhanced solid or a ring-like region): This type correlated with two histopathological types. One was stable or had a slowly proliferating tumoral tissue. Their specimens show a moderately increased vascularity and not so anaplastic tumor cells. The other was radiation-injury tissue. Here coagulation necrosis and fibrinoid necrosis were found, but no tumor cells. (2) Undelineated enhanced type (an undelineated and heterogeneously enhanced solid region): This type correlated with viable and highly proliferating glioma tissue. A high vascularity of the endotherial proliferating vessels, highly anaplastic tumor cells, and mitosis were observed. (3) Slightly enhanced type: In this area, edema with increasing capillary vessels was observed. Some tumor cells were also seen. (4) Non-enhanced type: Normal brain tissue; benign astrocytoma were not enhanced by Gd-DTPA. X-ray CT scanning is said to be unable to distinguish viable tumoral tissue from radiation-injury tissue. Histopathological correlations with Gd-DTPA-enhanced MR imagings have shown that the undelineated and heterogeneously enhanced areas corresponded to proliferating viable glioma tissue, while the delineated and homogeneously enhanced areas corresponded to radiation-injury tissue or to relatively stable glioma tissue. Gd-DTPA enhancement corresponded well to the increased vascularity of abnormal vessels, but not necessarily to tumoral cells. (author)

  13. Gd-DTPA-enhanced T{sub 1}-weighted excretory MR urography after low-dose diuretic injection; T{sub 1}-gewichtete MR-Ausscheidungsurographie mittels Gd-DTPA und vorheriger niedrigdosierter Gabe eines Diuretikums

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.; Buecker, A.; Adam, G.; Neuerburg, J.; Guenther, R.W. [Universitaetsklinikum der RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik

    1997-09-01

    Purpose: Assessment of the morphology of the urinary tract by gadolinium(Gd)-enhanced T{sub 1}-weighted MR-urography (MRU) and precontrast diuretic injection. Methods: MRU was performed in 5 patients using Gd-DTPA-enhanced coronal T{sub 1}-weighted 3D-gradient-echo sequences with different spatial resolution. Prior to contrast injection, 10 mg of furosemide were administered intravenously. Results: Secondary to the precontrast furosemide injection, the increase of the renal excretion rate allows complete visualisation of the entire collecting system within 10 minutes following Gd injection. Maximum intensity projections provide a three-dimensional overview of the ureters separate from the bladder. To achieve detailed anatomic imaging of the calices, both optimal distension and high resolution sequences are prerequisites which cannot be realized by means of survey urograms only. (orig./AJ) [Deutsch] Ziel: Darstellung der Morphologie der ableitenden Harnwege mittels T{sub 1}-gewichteter MR-Urographie (MRU) nach Gabe eines nierengaengigen Gadolinium(Gd)-Chelates und vorheriger Diuretikumapplikation. Methoden: Der Harntrakt von 5 Patienten wurde nach Injektion von Gd-DTPA mit koronaren T{sub 1}-gewichteten 3D-Gradienten-Echo-Sequenzen unterschiedlicher Ortsaufloesung untersucht. Vor der Kontrastmittelgabe wurden jeweils 10 mg Furosemid intravenoes verabreicht. Ergebnisse: Nach initialer Steigerung des Harnflusses durch Furosemidgabe wurden Uebersichtsurogramme mit vollstaendig durchzeichnenden Ureteren bereits 10 min nach Gd-Injektion erzielt. Maximumintensitaetsprojektionen ermoeglichten die Beurteilung des dreidimensionalen Verlaufes der Ureteren ohne Blasenueberlagerung. Eine genauere anatomische Darstellung der Nierenkelche erforderte neben einem guten Fuellungszustand eine moeglichst hohe Sequenzaufloesung, die mit Uebersichtsurogrammen allein nicht zu erreichen war. (orig./AJ)

  14. In vivo Gd-DTPA concentration for MR lung perfusion measurements: Assessment with computed tomography in a porcine model

    Energy Technology Data Exchange (ETDEWEB)

    Puderbach, Michael [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Deutsches Krebsforschungszentrum, Department of Radiology (E010), Heidelberg (Germany); Risse, Frank; Semmler, Wolfhard [German Cancer Research Center, Department of Medical Physics in Radiology, Heidelberg (Germany); Biederer, Juergen [University Hospital Schleswig-Holstein, Department of Diagnostic Radiology, Campus Kiel (Germany); Ley-Zaporozhan, Julia; Ley, Sebastian [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); University Heidelberg, Department of Pediatric Radiology, Heidelberg (Germany); Szabo, Gabor [University Heidelberg, Department of Cardiac Surgery, Heidelberg (Germany); Kauczor, Hans-Ulrich [University of Heidelberg, Department of Radiology, Heidelberg (Germany)

    2008-10-15

    A linear relationship between MR signal and contrast-agent concentration (CAC) of the arterial-input function (AIF) is crucial for MR lung-perfusion quantification. The aim was to determine the in-vivo real maximum CAC of the AIF, using cine CT measurements in a porcine model. A dilution series (Gd-DTPA, 0-20 mM) was examined by clinical time-resolved 3D-GRE MRI and by MDCT in cine CT mode. Using the CT setup, data were acquired in five pigs immediately after the injection of 0.05 mmol and 0.07 mmol/kg BW Gd-DTPA. For phantom measurements, mean signal values were determined using a region-of-interest (ROI) analysis and for animal measurements, a ROI was placed in the pulmonary trunk of the cine CT perfusion data sets. The CT phantom measurements were used to calculate the in-vivo maximum CAC corresponding to the HU values obtained in the pulmonary trunk by the cine CT study. Linearity of the AIF of the CT perfusion measurements was verified using the MR phantom measurement results. MR phantom measurements demonstrated linearity for concentrations of 0-4 mM. CT phantom measurements showed linear relation for the entire CAC range. Comparing in-vivo and in-vitro measurements, three of five CA injections at 0.05 mmol/kg and all 0.07 mmol/kg injections exceeded the range of linearity in MRI. The CA dose for quantification of lung perfusion with time-resolved MR studies must be chosen carefully since even with low doses (0.05 mmol/kg) the CAC may exceed the range of linearity in the AIF. (orig.)

  15. Detectability of hepatocellular carcinoma: comparison of Gd-DTPA-enhanced and SPIO-enhanced MR imaging

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Lee, Jeong Min; Kim In Hwan; Kim, Chong Soo; Han, Hyeun Young; Yoon, Kwon ha; Shin, Kyung Sook

    2000-01-01

    To compare the detectability of hepatocellular carcinoma (HCC) using superparamagnetic iron oxide (SPIO)-enhanced T2-weighted turbo spin echo (TSE), SPIO-enhanced T2-weighted FISP, and dynamic Gd-DTPA-enhanced fast low-angle shot (FLASH) MR images. In order to assess their hepatic lesions, 25 patients (20 men and 5 women) with HCC were enrolled in an MR study in which both gadolinium and Spiro were used. Since the lesions were most conspicuous during the phase of dynamic arterial dominant phase of dynamic gadolinium-enhanced imaging, this was the phase used for analysis. Images were analyzed qualitatively and quantitatively, and to compare the diagnostic value of gadolinium-enhanced imaging with that of SPIO-enhanced imaging for the detection of HCCs, a receiver-operated characteristic curve was obtained. Qualitative analysis revealed a significantly higher percentage of signal loss and a higher liver-lesion contrast-to-noise ratio on SPIO-enhanced FISP imaging than on SPIO-enhanced T2-weighted TSE imaging (p less than 0.05). It also showed that the lesions were most clearly visible on SPIO-enhanced FISP imaging (and significantly so), followed by SPIO-enhanced T2-weighted TSE imaging, and dynamic gadolinium-enhanced imaging. Imaging artifacts were more prominent on SPIO-enhanced T2-weighted TSE than on SPIO-enhanced PISF imaging or dynamic gadolinium-enhanced imaging (p less than 0.05). According to ROC analysis, SPIO-enhanced T2-weighted turbo spin echo (TSE) or SPIO-enhanced FISP imaging achieved higher accuracy than did dynamic gadolinium-enhanced FLASH imaging (p less than 0.05). For the detection of hepatocellular carcinomas, SPIO-enhanced MR imaging is better than gadolinium-enhanced FLASH imaging

  16. In vivo transport of Gd-DTPA2- into human meniscus and cartilage assessed with delayed gadolinium-enhanced MRI of cartilage (dGEMRIC)

    Science.gov (United States)

    2014-01-01

    Background Impaired stability is a risk factor in knee osteoarthritis (OA), where the whole joint and not only the joint cartilage is affected. The meniscus provides joint stability and is involved in the early pathological progress of OA. Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) has been used to identify pre-radiographic changes in the cartilage in OA, but has been used less commonly to examine the meniscus, and then using only a double dose of the contrast agent. The purpose of this study was to enable improved early OA diagnosis by investigate the temporal contrast agent distribution in the meniscus and femoral cartilage simultaneously, in healthy volunteers, using 3D dGEMRIC at two different doses of the contrast agent Gd-DTPA2-. Methods The right knee in 12 asymptomatic volunteers was examined using a 3D Look-Locker sequence on two occasions after an intravenous injection of a double or triple dose of Gd-DTPA2- (0.2 or 0.3 mmol/kg body weight). The relaxation time (T1) and relaxation rate (R1 = 1/T1) were measured in the meniscus and femoral cartilage before, and 60, 90, 120 and 180 minutes after injection, and the change in relaxation rate (ΔR1) was calculated. Paired t-test and Analysis of Variance (ANOVA) were used for statistical evaluation. Results The triple dose yielded higher concentrations of Gd-DTPA2- in the meniscus and cartilage than the double dose, but provided no additional information. The observed patterns of ΔR1 were similar for double and triple doses of the contrast agent. ΔR1 was higher in the meniscus than in femoral cartilage in the corresponding compartments at all time points after injection. ΔR1 increased until 90-180 minutes in both the cartilage and the meniscus (p meniscus at all time points (p meniscus, than in the avascular central part of the posterior medial meniscus during the first 60 minutes (p meniscus and cartilage simultaneously using dGEMRIC, preferably 90 minutes after the injection of a

  17. Gd-DTPA enhancement of the facial nerve in Ramsay Hunt's syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Kato, Tsutomu; Yanagida, Masahiro; Yamauchi, Yasuo (Kansai Medical School, Moriguchi, Osaka (Japan)) (and others)

    1992-10-01

    A total of 21 MR images in 16 Ramsay Hunt's syndrome were evaluated. In all images, the involved side of peripheral facial nerve were enhanced in intensity after Gd-DTPA. However, 2 cases had recovered facial palsy when MR images were taken. Nine of 19 cases with the enhancement of internal auditory canal portion had vertigo or tinnitus. Thus, it was suggested that the enhancement of internal auditory canal portion and clinical feature are closely related. (author).

  18. Gd-DTPA enhancement of the facial nerve in Ramsay Hunt's syndrome

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Yanagida, Masahiro; Yamauchi, Yasuo

    1992-01-01

    A total of 21 MR images in 16 Ramsay Hunt's syndrome were evaluated. In all images, the involved side of peripheral facial nerve were enhanced in intensity after Gd-DTPA. However, 2 cases had recovered facial palsy when MR images were taken. Nine of 19 cases with the enhancement of internal auditory canal portion had vertigo or tinnitus. Thus, it was suggested that the enhancement of internal auditory canal portion and clinical feature are closely related. (author)

  19. Assessment of left ventricular hemodynamics by Gd-DTPA enhanced high speed cine MRI

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiro

    1992-01-01

    To assess the validity of Gd-DTPA enhanced high speed cine MRI in left ventricular (LV) volumes and ejection fraction (EF), high speed cine MRI was compared with intra-venous digital subtraction left ventriculography (IV-DSA) in 14 patients. All patients underwent conventional cine MRI and Gd-DTPA enhanced high speed MRI, simultaneously. The pulse sequences of high speed MRI were TR 8 ms (TR 6 ms plus rewind pulse 2 ms), TE 3.2 ms, matrix 128, phase encode 8 or 6 and NEX 1. Comparison with LV-volume showed a high correlation (y = 0.854x + 1,699, r = 0.985) between high speed cine MRI and VI-DSA. To make left ventricular volume curve by area-length method in cine MRI, manual tracing of LV-cavity was more difficult in conventional cine MRI-method than enhanced high speed cine MRI-method. In conclusion, first pass-Gd-DTPA enhanced high speed cine MRI, using the horizontal long axis approach and the multiphase study, is a highly, accurate reproducible method of evaluating LV-volumetry. (author)

  20. Oral contrast agents in abdominal MR imaging

    International Nuclear Information System (INIS)

    Heuck, A.F.; Schhidbauer, E.; Allgayer, B.

    1991-01-01

    This paper compares Gd-DTPA, FE 2+ SO 4 , and Fe 2 Cl 3 -EDTA solutions as oral contrast agents in abdominal/pelvic MR imaging. MR imaging was performed at 1.5 T in 62 patients with tumors or inflammatory disorders of the abdomen and pelvis and in 28 normal volunteers. After precontrast imaging, an oral contrast medium was administered. Thirty subjects received 700-1,200 mL of a Gd-DTPA solution (1.0 mM; 15 g of mannitol per liter), 30 ingested the same amount of 5.0 mM Fe 2+ SO 4 , and 30 received Fe 2 Cl 3 -EDTA solution. The postcontrast study included T1- and T2-weighted spin-echo sequences and T1- and T2*-weighted gradient-echo sequences. Bowel peristalsis was reduced with intravenous application of Buscopan. Gd-DTPA, Fe 2+ SO 4 solution, and Fe 2 Cl 3 -EDTA solution provided homogeneous hyperintense signal intensity and high contrast of stomach and duodenum in all sequences, with significantly improved delineation of pathologic structures and abdominal organs in 78% of cases. Best contrast was achieved in T1-weighted sequences

  1. MR imaging with Gd-DTPA in tumors of the larynx and hypopharynx

    International Nuclear Information System (INIS)

    Vogl, T.J.; Steger, W.; Grevers, G.; Schedel, H.; Lissner, J.

    1990-01-01

    This paper reports on 31 patients with tumors of the larynx and hyupopharynx, the results of preoperative MR imaging were correlated with clinical laryngoscopic findings and the pathologic tumor classification. MR examinations were performed at 1.0 T with T1-weighted and T2-weighted spin-echo sequences. Laryngeal tumors, hypopharyngeal tumors, laryngoceles, and amyloid and inflammatory structures were found. In laryngeal lesions, transverse and coronal sections proved helpful; in hypopharyngeal expansions, transverse and sagittal sections were preferred. The most accurate diagnostic findings were achieved with Gd-DTPA-enhanced images, and subtraction technique enabled exact judgment of deep infiltration

  2. New perspective for GdNCT. Gd-DTPA reaches the nucleus of glioblastoma cells in culture and in vivo

    International Nuclear Information System (INIS)

    Stasio, G. de; Gilbert, B.; Frazer, B.H.

    2000-01-01

    We investigated the prospects of gadolinium as a neutron capture therapy agent by combining three independent techniques to study the uptake of Gd-DTPA in vitro, in cultured glioblastoma cells, and in vivo, in the glioblastoma tissue sections after injection of Gd-DTPA and tumor extraction. We show that gadolinium not only penetrates the plasma membrane of glioblastoma cells grown in culture, but we also observe a statistically significant higher concentration of Gd in the nucleus relative to the cytoplasm. For the in vivo experiments, Gd-DTPA was administered to 6 glioblastoma patients before neurosurgery. The extracted bioptic tissue was then analyzed with spectromictroscopy, showing Gd localized in the nuclei of glioblastoma cells in 5 patients out of the 6 analyzed. (author)

  3. Hybrid core shell nanoparticles entrapping Gd-DTPA and18F-FDG for simultaneous PET/MRI acquisitions.

    Science.gov (United States)

    Vecchione, Donatella; Aiello, Marco; Cavaliere, Carlo; Nicolai, Emanuele; Netti, Paolo Antonio; Torino, Enza

    2017-09-01

    Although there has been an improvement in the hardware and software of the PET/MRI system, the development of the nanoprobes exploiting the simultaneous acquisition of the bimodal data is still under investigation. Moreover, few studies on biocompatible and clinically relevant probes are available. This work presents a core-shell polymeric nanocarrier with improved relaxometric properties for simultaneous PET/MRI acquisitions. Core-shell nanoparticles entrapping the Gd-DTPA and 18 F-FDG are obtained by a complex coacervation. The boosting of r 1 of the entrapped Gd-DTPA up to five-times compared with 'free Gd-DTPA', is confirmed by the PET/MRI scan. The sorption of 18 F-FDG into the nanoparticles is studied and designed to be integrated downstream for the production of the tracer.

  4. Gd-DTPA-enhanced lesions in the brain of patients with acute optic neuritis

    DEFF Research Database (Denmark)

    Christiansen, P; Frederiksen, J L; Henriksen, O

    1992-01-01

    The cerebral hemispheres of 19 patients with acute monosymptomatic optic neuritis (AMON) were investigated using magnetic resonance imaging (MRI) and Gadolinium-DTPA (Gd-DTPA). Using T1-weighted and T2-weighted imaging sequences it was disclosed that 14 of 19 patients had lesions and that enhance......The cerebral hemispheres of 19 patients with acute monosymptomatic optic neuritis (AMON) were investigated using magnetic resonance imaging (MRI) and Gadolinium-DTPA (Gd-DTPA). Using T1-weighted and T2-weighted imaging sequences it was disclosed that 14 of 19 patients had lesions...... and that enhancement was seen in seven patients. It is known that patients with AMON and silent lesions in the CNS have a highly increased risk of developing multiple sclerosis (MS) later on. If it is accepted that a silent lesion in patients with AMON does represent a multiple sclerosis (MS) plaque......, and that an enhancing silent lesion represents an acute MS lesion, we may hypothesize that the disease process ultimately leading to MS starts long before the first symptom or sign ever appears. It would seem that at least half of the silent lesions in the cerebral hemispheres of patients with AMON had existed before...

  5. Study for synovial lesions by MRI using gadolinium-DTPA (Gd-DTPA) in patients with early phase of rheumatoid arthritis

    International Nuclear Information System (INIS)

    Takano, Keiyu

    1993-01-01

    To evaluate the usefulness of magnetic resonanse imaging (MRI) enhanced with gadolinium-DTPA (Gd-DTPA) for the detection of the inflamed synovium and for the evaluation of the responce to therapy in rheumatoid arthritis, we studied 49 patients with rheumatoid arthritis (RA) according to the 1987 revised criteria of American Rheumatism Association (ARA), 6 patients with systemic lupus erythematosus (SLE) complicated by arthritis, 3 patients with osteoarthritis (OA), 2 patients with Sjoegren syndrome, 2 patients with progressive systemic sclerosis and 10 healthy volunteers as an age matched control. The 49 patients with RA were divided into three groups: 1) early phase of RA, 2) non progressing RA and 3) slowly progressing RA, and the stage classification of plain X-ray film and enhancement pattern of MR imaging were classified into three groups. Synovial enhancement showed a linear, band-like or diffuse pattern. Almost all cases in early phase of RA group and non progressing RA group showed a linear pattern, a band-like pattern or even no enhancement, while slowly progressing group of stage II or higher showed the diffuse pattern of enhancement in all except 2 cases. Moreover, the linear pattern, the band-like pattern or even no contrast enhancement were seen in all except 1 stage I patient, whereas 26 out of 29 patients with stage II or higher change showed diffuse contrast enhancement. Furthermore, a comparison of MR images before and after administration of disease modifying antirheumatic drugs (DMARDs) in 10 patients showed that the improvement of clinical symptomes correlated fairly well with reduction of contrast enhancement. The present study suggested that MRI of the wrist using Gd-DTPA enhancement may be useful for the diagnosis of RA, the prediction of articular damage, and judgement of the response to therapy. (author)

  6. Study for synovial lesions by MRI using gadolinium-DTPA (Gd-DTPA) in patients with early phase of rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Takano, Keiyu (Saint Marianna Univ., Kawasaki, Kanagawa (Japan). School of Medicine)

    1993-02-01

    To evaluate the usefulness of magnetic resonanse imaging (MRI) enhanced with gadolinium-DTPA (Gd-DTPA) for the detection of the inflamed synovium and for the evaluation of the responce to therapy in rheumatoid arthritis, we studied 49 patients with rheumatoid arthritis (RA) according to the 1987 revised criteria of American Rheumatism Association (ARA), 6 patients with systemic lupus erythematosus (SLE) complicated by arthritis, 3 patients with osteoarthritis (OA), 2 patients with Sjoegren syndrome, 2 patients with progressive systemic sclerosis and 10 healthy volunteers as an age matched control. The 49 patients with RA were divided into three groups: (1) early phase of RA, (2) non progressing RA and (3) slowly progressing RA, and the stage classification of plain X-ray film and enhancement pattern of MR imaging were classified into three groups. Synovial enhancement showed a linear, band-like or diffuse pattern. Almost all cases in early phase of RA group and non progressing RA group showed a linear pattern, a band-like pattern or even no enhancement, while slowly progressing group of stage II or higher showed the diffuse pattern of enhancement in all except 2 cases. Moreover, the linear pattern, the band-like pattern or even no contrast enhancement were seen in all except 1 stage I patient, whereas 26 out of 29 patients with stage II or higher change showed diffuse contrast enhancement. Furthermore, a comparison of MR images before and after administration of disease modifying antirheumatic drugs (DMARDs) in 10 patients showed that the improvement of clinical symptomes correlated fairly well with reduction of contrast enhancement. The present study suggested that MRI of the wrist using Gd-DTPA enhancement may be useful for the diagnosis of RA, the prediction of articular damage, and judgement of the response to therapy. (author).

  7. Cerebral and meningeal manifestations of AIDS: comparison of plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 105 patients

    International Nuclear Information System (INIS)

    Jochens, R.; Henkes, H.; Steinkamp, H.J.; Terstegge, K.; Hosten, N.; Ruf, B.; Schoerner, W.

    1994-01-01

    The purpose of the present study was to evaluate the potential of T1-weighted Gd-DTPA enhanced MR imaging in the diagnosis of cerebral manifestations of AIDS. 105 patients with AIDS were imaged with plain T2-weighted images as well as with Gd-DTPA enhanced T1-weighted pulse sequences. Our study revealed comparable sensitivities in the detection of morphological changes as shown on plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 55% of patients (normal and pathologic findings). Plain T2-weighted images were superior in 28.5% and provided significantly better results in 8.5% of patients. Gd-DTPA enhanced T1-weighted images were superior in only 5% cases and revealed significantly better results in 3%. As a result, T2-weighted plain images were superior in approximately 40% of patients concerning detection of morphologic changes. In almost 10% of patients with parechymal and meningeal lesions, Gd-DTPA enhanced T1-weighted images, however, were superior or even significantly better compared to T2-weighted plain images. The detection of morphologic changes in MR imaging can be further increased with Gd-DTPA. With regard to differential diagnosis and diesease activity, plain T2-weighted images and Gd-DTPA enhanced T1-weighted images revealed comparable results in 42% of patients (normal and pathologic findings). T2-weighted plain images were superior in 2% of cases whereas Gd-DTPA enhanced T1-weighted images were superior in as much as 56% of patient. MR imaging enhanced with Gd-DTPA yielded additional information on disease activity in 73% of patients with pathologic findings in the cerebral parechyma and the meninges. The surplus of information also refers to the etiology of cerebral pathology and differential diagnosis. Because of the frequency of cerebral manifestations in AIDS, early diagnosis for initiation of therapy and follow-up studies to monitor therapy are crucial. (orig./MG) [de

  8. Contrast-enhanced MR angiography of the arterial and portovenous system of the liver with varying concentrations of contrast medium; Kontrastmittel-gestuetzte 3D-MR-Angiographie des arteriellen und portalvenoesen Gefaesssysteme der Leber mit unterschiedlicher KM-Konzentration

    Energy Technology Data Exchange (ETDEWEB)

    Vosshenrich, R.; Engeroff, B.; Obenauer, S.; Grabbe, E. [Klinikum der Georg-August-Universitaet, Goettingen (Germany). Abt. Diagnostische Radiologie

    2003-09-01

    Purpose: To evaluate the diagnostic value of a higher concentrated contrast medium (gadobutrol) for contrast-enhanced MRA of the hepatic arteries and portovenous system. Materials and methods: The examinations were performed on a 1.5-Tesla whole body imaging system (Magnetom Symphony Quantum, Siemens) with a 30-mTesla/m gradient field strength using a phased-array body coil. A 3D FLASH sequence (TR/TE/FA 3.88 ms/1.44 ms/25 ) was used imaging the hepatic arteries and portovenous system after determination of the circulation time. The study included 50 patients, with 25 patients (group 1) injected with 0.2 mmol Gd-GTPA/kg body weight and 25 patients (group 2) injected with 0.1 mmol gadobutrol/kg body weight. The signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR) were calculated for both groups. The image quality was graded by three radiologists on a 5-point scale. Results: The highest SNR was measured in group 1, with no statistically significant differences of the SNR in the abdominal aortal, coeliac trunk and common hepatic artery. CNR was also similar in both groups. Likewise, portal, superior mesenteric and splenic veins showed no statistically significant differences. All cases were found to have a good image quality. Conclusion: For MRA of the hepatic arteries and the portal veins, the higher concentrated Gd-DTPA contrast medium gadobutrol can be used at half the dosage recommended for the standard Gd-DTPA contrast medium. (orig.) [German] Ziel: Die vorliegende Studie soll den Stellenwert eines hoeher konzentrierten Kontrastmittels (KM) fuer die 3D-MR-Angiographie (MRA) der arteriellen und portalvenoesen Lebergefaesse evaluieren. Methoden: Die Durchfuehrung der Untersuchungen erfolgte an einem Magnetom Symphony/Quantum mit einer Feldstaerke von 1.5 T und einer Gradientenstaerke von 30 mT/m unter Verwendung einer Koerper-Array-Spule. Zur Anwendung kam eine 3D-FLASH-Sequenz (TR/TE/FA 3,88 ms/1,44 ms/25 ). Untersucht wurde das arterielle und

  9. Oral contrast media for MR imaging of the abdomen. Pt. 4

    International Nuclear Information System (INIS)

    Kaminsky, S.; Gogoll, M.; Kornmesser, W.; Felix, R.

    1992-01-01

    Safety and efficacy of gadopentetate-dimeglumine (Gd-DTPA) as a MR bowel contrast agent were determined in 133 patients with CT-proved abdominal and retroperitoneal mass lesions using a buffered formulation (1 mmol/l Gd-DTPA, 15 g/l mannitol, 25 mmol/l sodium-citrate, 6- 17 ml/kg). Short-lived gastrointestinal side effects were noted in 32% of patients. Gd-DTPA provided uniform, hyperintense bowel labelling and contrast enhancement in the region of interest in 81% of patients. Among 78 patients with pre- and postcontrast images lesion delineation was improved in 62%. In 55 studies with postcontrast images only, Gd-DTPA proved useful in 65%. In 105 of 109 cases IV injection of scopolamine or glucagon eliminated image artifacts arising from peristaltis of opacified bowel. The authors conclude that Gd-DTPA is a safe and effective MR bowel contrast agent. (orig.) [de

  10. In vivo quantification of the unidirectional influx constant for Gd-DTPA diffusion across the myocardial capillaries with MR imaging

    DEFF Research Database (Denmark)

    Larsson, H B; Stubgaard, M; Søndergaard, Lise

    1994-01-01

    ) and the perfusion (F) by the equation Ki = E.F.Ki was obtained by using the longitudinal relaxation rate (R1) as a measure of the myocardial concentration of Gd-DTPA in the mathematical model for transcapillary transport across capillary membranes. Myocardial enhancement after Gd-DTPA injection was followed...... by using inversion-recovery Turbo-FLASH (fast low-angle shot) images obtained in real time. The results were comparable to those obtained from studies with positron emission tomography in humans and invasive studies in animals. A method for obtaining the input function noninvasively is also presented....... Comparison with direct arterial blood sampling showed that the noninvasive input function may be even more accurate with regard to timing and curve shape than the invasive input function. The procedure may therefore prove useful in clinical studies....

  11. Myocardial tissue characterization in hypertrophic cardiomyopathy. Comparison between Gd-DTPA enhanced MR signal intensity ratio and myocardial biopsy

    Energy Technology Data Exchange (ETDEWEB)

    Tsukihashi, Hironori; Shimada, Toshio; Ishibashi, Yutaka [Shimane Medical Univ., Izumo (Japan)] [and others

    1995-09-01

    The aim of this study is to demonstrate whether Gd-DTPA enhanced magnetic resonance imaging (Gd-EMRI) can be used to evaluate myocardial tissue characterization. We performed Gd-EMRI in 20 patients with hypertrophic cardiomyopathy (HCM) and 6 normal controls. Ventricular myocardial biopsy was performed in 7 patients. Gd-EMRI was obtained every 10 minutes from 5 to 50 minutes after intravenous Gd-DTPA (0.1 mmol/kg) injection. Signal intensity (SI) in hypertrophic region of myocardium was measured from LV short axis image. We standardized the data according to following equations. IR (intensity ratio) =SI (myocardium) /SI (skeletal muscle). SIR=IR (in time course) /IR (before Gd-DTPA injection). SIR in HCM was delayed in time course compared with that in normal controls. Interstitial fibrosis was prominent when SIR (peak) minus SIR (40min. after) /SIR (peak) was small. The delayed decay of IR in HCM was closely related to the grade of interstitial fibrosis rather than the edema of interstitial tissue or the myocardial cell diameter. We conclude that the decay analysis with Gd-EMRI is useful to evaluate myocardial tissue characterization closely related to myocardial fibrosis in comparison with cardiac histology. (author).

  12. MRI enhancement of the facial nerve with Gd-DTPA, 2

    International Nuclear Information System (INIS)

    Yanagida, Masahiro

    1993-01-01

    We performed enhanced MRI using Gd-DTPA in 84 patients with facial palsy. After assessing enhancement of the normal facial nerve, we examined enhancement in patients with Bell's palsy and Ramsay Hunt syndrome. In 95% of patients with Bell's palsy, enhancement was obtained in the distal IAC and labyrinthine portions. In 72%, enhancement was significant from the distal IAC portion through the vertical portion. In some of the patients who underwent enhanced MRI twice, increased signal intensity was observed in distal portions such as the vertical portion. In many cases of Ramsay Hunt syndrome, enhancement was seen extensively in the IAC portion through the vertical portion. In the subjects with internal auditory symptoms such as vertigo and tinnitus, enhancement of the IAC portion was seen not only in the facial nerve but also in the vestibular and the cochlear nerves. These results suggest that the vascular permeability of lesions in Bell's palsy may be increased from the distal IAC portion to the vertical portion. Judging from the present findings with Ramsay Hunt syndrome, symptoms related to the enhanced portions suggest that accompanying internal auditory symptoms occur due to inflammation of the IAC portions of cochlear and vestibular nerves. (author)

  13. Assessment of fixed charge density in regenerated cartilage by Gd-DTPA-enhanced MRI

    International Nuclear Information System (INIS)

    Miyata, Shogo; Homma, Kazuhiro; Numano, Tomokazu; Furukawa, Katsuko; Tateishi, Tetsuya; Ushida, Takashi

    2006-01-01

    Applying regenerated cartilage in a clinical setting requires noninvasive evaluation to detect the maturity of cartilage tissue. Magnetic resonance (MR) imaging of articular cartilage is well accepted and has been applied clinically in recent years. We attempt to establish a noninvasive method to evaluate the maturity of regenerated cartilage tissue using gadolinium-enhanced MR imaging. To reconstruct cartilaginous tissue, we embedded articular chondrocytes harvested from bovine humeral head in agarose gel and cultured the cells in vitro up to 4 weeks. The fixed charge density (FCD) of the cartilage was determined using MRI gadolinium exclusion method. The sulfated glycosaminoglycan (sGAG) content was determined by dimethylmethylene blue dye-binding assay. The sGAG content and FCD of the regenerated cartilage increased with duration of culture. In the T 1 Gd maps, the [Gd-DTPA 2- ] in the specimen decreased, and the boundary between the sample disk and the bath solution of phosphate buffered saline (PBS) became clearer as time in culture increased. In the linear regression analysis, FCD and sGAG content correlated significantly. Gadolinium-enhanced MR imaging measurements can be useful predictors of the degree of cartilaginous tissue formation. (author)

  14. Cerebral and meningeal manifestations of AIDS: comparison of plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 105 patients; Zerebrale und meningeale Manifestationen des AIDS: Vergleich von nativer T2-gewichteter und Gd-DTPA unterstuetzter T1-gewichteter MRT (105 Patienten)

    Energy Technology Data Exchange (ETDEWEB)

    Jochens, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Henkes, H. [Klinik fuer Radiologische Diagnostik und Neuroradiologie, Alfried Krupp Krankenhaus, Essen (Germany); Steinkamp, H.J. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Terstegge, K. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Hosten, N. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Standort Wedding, Freie Univ. Berlin (Germany); Ruf, B. [II. Medizinische Klinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin, Standort Wedding (Germany); Schoerner, W. [Inst. fuer Roentgendiagnostik und Nuklearmedizin, Staedtisches Klinikum, Braunschweig (Germany)

    1994-12-31

    The purpose of the present study was to evaluate the potential of T1-weighted Gd-DTPA enhanced MR imaging in the diagnosis of cerebral manifestations of AIDS. 105 patients with AIDS were imaged with plain T2-weighted images as well as with Gd-DTPA enhanced T1-weighted pulse sequences. Our study revealed comparable sensitivities in the detection of morphological changes as shown on plain T2-weighted images and Gd-DTPA enhanced T1-weighted images in 55% of patients (normal and pathologic findings). Plain T2-weighted images were superior in 28.5% and provided significantly better results in 8.5% of patients. Gd-DTPA enhanced T1-weighted images were superior in only 5% cases and revealed significantly better results in 3%. T2-weighted plain images were superior in approximately 40% of patients concerning detection of morphologic changes. In almost 10% of patients with parechymal and meningeal lesions, Gd-DTPA enhanced T1-weighted images, however, were superior or even significantly better compared to T2-weighted plain images. The detection of morphologic changes in MR imaging can be further increased with Gd-DTPA. With regard to differential diagnosis and diesease activity, plain T2-weighted images and Gd-DTPA enhanced T1-weighted images revealed comparable results in 42% of patients (normal and pathologic findings). T2-weighted plain images were superior in 2% of cases whereas Gd-DTPA enhanced T1-weighted images were superior in as much as 56% of patient. MR imaging enhanced with Gd-DTPA yielded additional information on disease activity in 73% of patients with pathologic findings in the cerebral parechyma and the meninges. The surplus of information also refers to the etiology of cerebral pathology and differential diagnosis. Because of the frequency of cerebral manifestations in AIDS, early diagnosis for initiation of therapy and follow-up studies to monitor therapy are crucial. (orig./MG) [Deutsch] Den Stellenwert der T1-gewichteten Gd-DTPA unterstuetzten MRT im

  15. Dynamic Gd-DTPA enhanced breath-hold 1.5 t MRI of normal lungs and patients with interstitial lung disease and pulmonary nodules: preliminary results

    International Nuclear Information System (INIS)

    Semelka, R.C.; Maycher, B.; Shoenut, J.P.; Kroeker, R.; Griffin, P.; Lertzman, M.

    1992-01-01

    A FLASH technique was used, which encompassed the entire thorax in the transverse plane, before and after dynamic intravenous injection of godalinium DTPA (Gd-DTPA) to study 7 patients with normal lungs, 12 patients with interstitial lung disease (ILD), and 11 patients with pulmonary nodules. Comparative CT studies were obtained within 2 weeks of the MRI study in the patients with lung disease. Quantitative signal intensity (SI) measurements were performed. Qualitative evaluation of lung parenchyma was determined in a prospective blinded fashion, and in the normal group comparison was made with the CT images. In normal patients, SI of lung parenchyma increased by 7.7±1.3%. On precontrast images, second-order pulmonary branchings were visible while post-contrast, fifth- to sixth-order branches were apparent. In patients with ILD, interstitial changes enhanced to a variable extent, increases in SI ranging from minimal (49.9%) to substantial (308.4%). Detection of pulmonary nodules improved following contrast injection. The minimum lesion size detectable decreased from 8 mm precontrast to 5 mm post-contrast. Percentage contrast enhancement was greater for malignant nodules (124.2±79.7%) than benign nodules (5.8±4.7%) (p<0.01). (orig.)

  16. Measurement of the arterial concentration of Gd-DTPA using MRI: a step toward quantitative perfusion imaging

    DEFF Research Database (Denmark)

    Fritz-Hansen, T; Rostrup, Egill; Larsson, H B

    1996-01-01

    A noninvasive method using an inversion recovery turbo-FLASH for dynamic measurement of the arterial input function represented by the bolus passage of Gd-DTPA in the descending aorta is presented, and the results are compared with the input function obtained by arterial blood samples. A good...... accordance between the two input functions was found, indicating that it is possible to measure the input function to the myocardium using MRI. A variation between the two concentration curves of 5% at upslope, 2.7% at peak point, and ... inversion time peak concentration....

  17. Oral contrast media for MR imaging of the abdomen. Pt. 4. Clinical trail on safety and efficacy of gadopentetate-dimeglumine. Orale Kontrastmittel fuer die magnetische Resonanztomographie des Abdomens. T. 4. Klinische Pruefung der Vertraeglichkeit von Gadolinium-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Kaminsky, S.; Gogoll, M.; Kornmesser, W.; Felix, R. (Klinikum Rudolf Virchow, Berlin (Germany). Strahlenklinik und Poliklinik); Laniado, M. (Tuebingen Univ. (Germany). Radiologische Klinik); Clauss, W. (Schering AG, Berlin (Germany))

    1992-01-01

    Safety and efficacy of gadopentetate-dimeglumine (Gd-DTPA) as a MR bowel contrast agent were determined in 133 patients with CT-proved abdominal and retroperitoneal mass lesions using a buffered formulation (1 mmol/l Gd-DTPA, 15 g/l mannitol, 25 mmol/l sodium-citrate, 6- 17 ml/kg). Short-lived gastrointestinal side effects were noted in 32% of patients. Gd-DTPA provided uniform, hyperintense bowel labelling and contrast enhancement in the region of interest in 81% of patients. Among 78 patients with pre- and postcontrast images lesion delineation was improved in 62%. In 55 studies with postcontrast images only, Gd-DTPA proved useful in 65%. In 105 of 109 cases IV injection of scopolamine or glucagon eliminated image artifacts arising from peristaltis of opacified bowel. The authors conclude that Gd-DTPA is a safe and effective MR bowel contrast agent. (orig.).

  18. The thoracic aortography by Gd-DTPA enhanced ultrafast cine MR imaging. Assessment of thoracic aortic dilatation in aging and in patients with hypertension and aortic valve disease

    International Nuclear Information System (INIS)

    Matsumura, Kentaro; Nakase, Emiko; Kawai, Ichiyoshi; Saito, Takayuki; Kikkawa, Nobutada; Haiyama, Toru

    1995-01-01

    To assess the morphology of thoracic aorta, we had a trial of Gd-DTPA enhanced ultrafast cine MR imaging on the thoracic aorta. This method was provided with high quality thoracic aortogram during 15-20 seconds. In patients without hypertension and aortic valve disease, dimensions of ascending aorta and aortic arch were significantly correlated with aging. In patients with hypertension, dimensions of ascending aorta and aortic arch were significantly dilated. In patients with aortic valve disease, thoracic aorta was diffusely enlarged, especially in ascending aorta. Gd-DTPA enhanced ultrafact cine MR imaging was useful to assess the thoracic aortic anatomy and diseases. (author)

  19. Gd-DTPA enhanced MRI of the brain infarction: correlation between onset of infarction and enhancing patterns

    International Nuclear Information System (INIS)

    Joo, An Young; Kim, Myung Soon; Lee, Sung Soo

    1994-01-01

    To evaluate the correlation between onset of brain infarction and Gd-DTPA enhancing patterns on MRI. We reviewed MRI of 58 lesions in 45 patients with clinically documented brain infarction retrospectively. Axial, coronal and sagittal T1WI (TR/TE 450-520/20), T2WI (TR/TE 2190/90) and Gd-DTPA enhanced T1WI were performed with a 0.5T superconductive MR system. We analyzed Gd-enhancing patterns that were divided into intravascular, meningeal, and parenchymal enhancement. Parenchymal pattern was subdivided into mottled, partial ring like and dense enhancement. Intravascular enhancement was seen at 1-10 days in 30(53%) of 58 infarctions. Meningeal enhancement (13%) was noted at 1-6 days. Parenchymal enhancement (50%) was seen at 2-28 days and subdividing patterns are as follows: The mottled enhancement pattern was seen earlier at 2-8 days and partial ring like or dense enhancement patterns at 5-28 days. After reviewing Gd-enhanced MRI of infarction, the intravascular and meningeal enhancement patterns were earlier than parenchymal enhancement. Among parenchymal patterns, the mottled pattern was seen earlier than partial ring like or dense patterns. In conclusion, Gd-enhancing patterns of brain infarction are useful in estimating the age of infarction including acute infarction

  20. Comparison of contract appearance of gadobenate-dimeglumine and GA-DTPA in intra-axial brain tumors; Vergleich des Kontrastverhaltens von Gadobenat-Dimeglumine und Gd-DTPA bei intraaxialen Hirntumoren. Eine doppelblinde randomisierte intraindividuelle Cross-over-Studie

    Energy Technology Data Exchange (ETDEWEB)

    Essig, M.; Knopp, M.V. [Deutsches Krebsforschungszentrum Heidelberg (Germany). Abt. Radiologische Diagnostik und Therapie; Hartmann, M.; Jansen, O. [Abt. Klinische Neuroradiologie, Univ. Heidelberg (Germany); Lodemann, K.P.; Seeberg, A. [Bracco-Byk-Gulden, Konstanz (Germany); Runge, V.M. [Univ. of Kentucky, Lexington (United States)

    2001-12-01

    The purposes of the study was to assess intraaxial brain tumors by a blinded comparison of gadobenat-dimeglumine and Gd-DTPA 27 patients with known cerebral gliomas or metastases were included into an intra-individual randomized double-blinded cross-over study. The protocol included T1 SE, T2 FSE and after contrast a series of five T1 SE sequences followed by T1 SE with MT, T1 SE, and 3D GRE sequences. Imaging data acquired at two centers were assessed on-site by the investigators and off-site by two experienced readers using quantitative and qualitative criteria. For a quantitative analysis tumor contrast and contrast-to-noise ratios were determined out of ROI in tumor, unaffected white matter, a region outside the head, and an external reference tube. For the qualitative assessment on- and off-site readers were asked to compare both MR scans for lesion contrast, lesion delineation and information upon the internal morphology and structure. In the quantitative analysis lesions examined with gadobenat-dimeglumine present a maximal 26% increase of the lesion contrast. In both, the on-site, as well as the off-site assessment the intensity of enhancement and the lesion contrast were found to be significantly better with gadobenat-dimeglumine enhanced MRI. There was a trend towards gadobenat-dimeglumine for the delineation of the lesion from the surrounding tissue and the internal lesion morphology. Based on our observations gadobenat-dimeglumine proved to be a safe and valuable contrast media for the assessment of CNS neoplasms. Compared with Gd-DTPA it provides a more intense contrast enhancement and a better tumor contrast which might be of importance for the further management of these patients. (orig.) [German] In einer doppelt verblindeten randomisierten intraindividuel en Cross-Over Vergleichsuntersuchung wurden 27 Patienten mit intraaxialen Hirntumoren mittels der MR-Kontrastmittel Gadobenat-Dimeglumine (Multihance trademark) und Gd-DTPA (Magnevist{sup circled

  1. Application of EPI diffusion-weighted and Gd-DTPA T2* perfusion imaging in the diagnosis of brain ischemia

    International Nuclear Information System (INIS)

    Han Hongbin; Xie Jingxia

    1998-01-01

    Purpose: To study the MR and CT appearances of brain ischemia on diffusion-weighted imaging (DWI) and evaluate the role of EPI ADC-map, DWI and T 2 * perfusion imaging in acute stroke. Methods: DWI or ADC-map and routine T 1 WI and T 2 WI were performed in 36 patients with stroke (the time after onset of stroke: 2 hours - 2 months). Among them, 12 cases had perfusion imaging simultaneously. Results: Gd-DTPA T 2 * perfusion imaging demonstrated decrease of rrCBV and rrCBF in 10 cases; identical in 1 case and increase in 1 case. The mean transit time in the diseased area was longer than that of the contralateral corresponding region (paired t test: P 2 * perfusion imaging can demonstrate the decrease and restoration of CBF in the brain ischemic regions. DWI and ADC-map are highly valuable in the early diagnosis and monitoring the development of brain ischemic disease

  2. Value of contrast enhanced MR examination in orbital and optic tract pathology; Wartosc wzmocnienia kontrastowego w diagnostyce MR schorzen ukladu wzrokowego

    Energy Technology Data Exchange (ETDEWEB)

    Sosnowski, P. [Zaklad Radiologii Sercowo-Naczyniowej I.R., Akademia Medyczna, Poznan (Poland)

    1994-12-31

    The purpose of this study was the evaluation of utility of contrast enhancement in MR imaging of the orbital and optic tract pathology. Gd-DTPA , which was administered in 154 of 250 selected patients, influenced substantially on final diagnosis in 39 cases, in 13 of them in the crucial way. The greatest advantage of contrast enhancement was observed in the evaluation of ocular and optic nerve diseases, the meanest in optic chiasm compression cases. The indications for using contrast medium in the pathology of distal optic tract were similar to those used in other central nervous system diseases. (author) 7 refs, 4 figs, 3 tabs

  3. Indirect MR venography: contrast medium protocols, postprocessing and combination in diagnosing pulmonary emboli with MRI

    International Nuclear Information System (INIS)

    Kluge, A.; Bachmann, G.; Rominger, M.; Schoenburg, M.

    2004-01-01

    Purpose: Integration of MR venography in a comprehensive MR imaging protocol in patients with suspected pulmonary embolism (PE) and evaluation of contrast media dosage, timing and postprocessing for diagnostic accuracy. Materials and Methods: Fortyeight consecutive inpatients with suspected PE or deep vein thrombosis were examined by MR venography according to one of the following protocols: protocol I: MR venography only, 0.25 mmol/kg bodyweight (BW) Gadopentate dimeglumine(Gd-DTPA) as single dose, bolus timing; protocol II: MR angiography of pulmonary arteries with a cumulative dosage of 0.25 mmol/kg contrast media, modification of coil setting for MR venography without further contrast media application; protocol III: as protocol II but with 0.125 mmol/kg BW, followed by MR venography. Signal-to-noise ratio, contrast-to-noise ratio, number of definable vascular segments and image quality were evaluated. The results were compared to conventional bilateral venography. Results: All MR venography examinations were of diagnostic quality and the examination time was below 10 min. MR venography could be performed in all 48 patients comparted to 43 of 48 patients for conventional venography. Significantly more superficial and deep veins of the leg could be visualized by MR venography (94% compared to 83% for conventional venography). Sensitivity and specificity were 100% and 92%, respectively. Quality differed significantly between 0.125 mmol/kg (protocol III) and 0.25 mmol/kg Gd-DTPA (protocols I and II) while timing did not influence quality (protocol I vs. II). (orig.) [de

  4. Contrast-enhanced magnetic resonance angiography

    International Nuclear Information System (INIS)

    Vogl, T.J.; Hoffmann, Y.; Muehler, A.; Felix, R.

    1994-01-01

    Magnetic resonance angiography (MRA) protocols are based on standard sequence protocols like time of flight MRA, which evaluates inflowing spins. This technique is limited by a variety of artifacts like the saturation artifact via turbulent blood flow. Contrast media diminish these artifacts like extracellular agents and blood-pool contrast media. The clinical value of the contrast-enhanced MRA for cerebral pathologies is based on the use of the paramagnetic contrast agent Gd-DTPA. For extracerebral diseases this technique is restricted because of the simultaneous visualization of both arterial and venous vascular territorities. Occult venous sinus thrombosis or AV malformations are clinical essential indications for the use of C-MRA. Experimental data prove the excellent contrast abilities of blood-pool agents like Gd-DTPA-polylysin or Gd-DTPA-albumin, which demonstrate long intravascular persistence and retarded excretion. (orig.) [de

  5. Contrast-enhanced MR imaging monitoring of acute tumor response to chemotherapy

    International Nuclear Information System (INIS)

    Ranney, D.F.; Cohen, J.M.; Antich, P.P.; Endman, W.A.; Kulkarni, P.; Weinreb, J.C.; Giovanella, B.

    1987-01-01

    Treatment responses of human malignant melanomas were monitored at millimeter resolution in athymic mice by injecting a new polymeric contrast agent, Gd-DTPA-dextran (0.1 mmol Gd/kg, intravenously). Proton MR imaging (0.35 T, spin-echo, repetition time = 0.5 second, echo time = 50 msec) was performed 30 hours after administering diphtheria toxin. Pre-contrast medium images revealed only homogeneous intermediate-intensity tumor masses. Post-contrast medium images of untreated (viable) tumors demonstrated 32% enhancement throughout the entire mass. Post-contrast medium images of toxin-treated tumors revealed marked enhancement (65%) of the histologically viable outer rims, lesser enhancement (38%) of heavily damaged subregions, and no enhancement of dead tumor. These acute, contrast medium-enhanced MR images accurately identified tumor subregions that survived for longer than one week

  6. Enhanced conjugation stability and blood circulation time of macromolecular gadolinium-DTPA contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Jenjob, Ratchapol [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of); Kun, Na [Department of Biotechnology, The Catholic University of Korea, 43 Jibong-ro, Wonmi-gu, Bucheon-si, Gyeonggi-do 420-743 (Korea, Republic of); Ghee, Jung Yeon [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Shen, Zheyu; Wu, Xiaoxia [Division of Functional Materials and Nano-Devices, Ningbo Institute of Materials Technology & Engineering (NIMTE), Chinese Academy of Sciences, 519 Zhuangshi Street, Zhenhai District, Ningbo, Zhejiang 315201 (China); Cho, Steve K., E-mail: scho@gist.ac.kr [Division of Liberal Arts and Science, GIST College, Gwangju Institute of Science and Technology, Gwangju 500-712 (Korea, Republic of); Lee, Don Haeng [Utah-Inha DDS and Advanced Therapeutics, B-403 Meet-You-All Tower, SongdoTechnopark, 7–50, Songdo-dong, Yeonsu-gu, Incheon 406-840 (Korea, Republic of); Department of Internal Medicine, School of Medicine, Inha University Hospital, Incheon 420-751 (Korea, Republic of); Yang, Su-Geun, E-mail: Sugeun.Yang@Inha.ac.kr [Department of New Drug Development, School of Medicine, Inha University, 2F A-dong, Jeongseok Bldg., Sinheung-dong 3-ga, Jung-gu, Incheon 400-712 (Korea, Republic of)

    2016-04-01

    In this study, we prepared macromolecular MR T1 contrast agent: pullulan-conjugated Gd diethylene triamine pentaacetate (Gd-DTPA-Pullulan) and estimated residual free Gd{sup 3+}, chelation stability in competition with metal ions, plasma and tissue pharmacokinetics, and abdominal MR contrast on rats. Residual free Gd{sup 3+} in Gd-DTPA-Pullulan was measured using colorimetric spectroscopy. The transmetalation of Gd{sup 3+} incubated with Ca{sup 2+} was performed by using a dialysis membrane (MWCO 100–500 Da) and investigated by ICP-OES. The plasma concentration profiles of Gd-DTPA-Pullulan were estimated after intravenous injection at a dose 0.1 mmol/kg of Gd. The coronal-plane abdominal images of normal rats were observed by MR imaging. The content of free Gd{sup 3+}, the toxic residual form, was less than 0.01%. Chelation stability of Gd-DTPA-Pullulan was estimated, and only 0.2% and 0.00045% of Gd{sup 3+} were released from Gd-DTPA-Pullulan after 2 h incubation with Ca{sup 2+} and Fe{sup 2+}, respectively. Gd-DTPA-Pullulan displayed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h), much longer than 0.11 h and 0.79 h of Gd-EOB-DTPA. Abdominal MR imaging showed Gd-DTPA-Pullulan maintained initial MR contrast for 30 min. The extended plasma half-life of Gd-DTPA-Pullulan probably allows the prolonged MR acquisition time in clinic with enhanced MR contrast. - Highlights: • Macromolecule (pullulan) conjugated Gd contrast agent (Gd-DTPA-Pullulan) showed the extended plasma half-life (t{sub 1/2,α} = 0.43 h, t{sub 1/2,β} = 2.32 h) in comparison with Gd-EOB-DTPA • Gd-DTPA-pullulan T1 contrast agent exhibited strong chelation stability against Gd. • The extended blood circulation attributed the enhanced and prolonged MR contrast on abdominal region of rats. • The extended blood circulation may provide prolonged MR acquisition time window in clinics.

  7. The use of new contrast media agents in radiology

    International Nuclear Information System (INIS)

    Zerbe, M.

    1992-01-01

    The purpose of the document is to present the importance of different categories of contrast media in radiography. Ionic and non-ionic contrast media are presented. Pharmacology and pathophysiology of Iodine contrast media with their effects on special organs of the body like the heart, vessels, lungs and nervous systems are explained. Paramagnetic contrast media used in NMR imaging are presented too. Emphasis is made on contrast media based on Gadolinium like Gd-DTPA, Gd-CL3, Gd-EDTA. Actions of Gd-DTPA applied to images in urography are pointed out

  8. Table-moving contrast-enhanced MR angiography. Evaluation of imaging methods and its vascular signal characters

    Energy Technology Data Exchange (ETDEWEB)

    Amanuma, Makoto; Yoshida, Tadashi; Hirata, Hisashi; Kozawa, Eito; Enomoto, Kyoko; Watabe, Tsuneya; Heshiki, Atsuko [Saitama Medical School, Moroyama (Japan)

    1999-10-01

    Signal characteristics of table-moving contrast enhanced MR angiography (MRA) were analyzed in 31 consecutive patients. Imaging was performed at four different stations continuously before and after Gd-DTPA infusion and subtracted MRA were processed. Signal to noise ratio (SNR) of the main arteries was measured at 11 different points and their distribution pattern was compared relative to its position and dose of Gd-DTPA. Degree of arterial and venous demonstration was also scored by two radiologists. Arterial signal in the proximal stations showed significantly higher value than that in distal stations. In a single station, the proximal part of arterial main stem also had higher signal value than did distal part. The signal difference was largest in the proximal station. Although higher dose of contrast medium provided higher vascular signal, image quality was also clinically acceptable in the nearly single dose (0.10-0.15 mmol/kg). By optimizing imaging parameters, high quality whole-body MRA was possible even with single dose of contrast medium. (author)

  9. Ioversol contrast medium in canine neuroradiology

    International Nuclear Information System (INIS)

    Tudury, E.A.; Arias, M.V.B.; Camargo, P.L. de; Faria, M. de L.E.; Machado, C.E.G.

    1997-01-01

    Ioversol, a non-ionic, hydrosoluble iodine contrast medium at a concentration of 320mg I/ml was used to perform 26 contrast neuroradiographic studies (myelography, epidurography and cerebral ventriculography) in 22 dogs. Since this contrast medium is rapidly absorbed, proper radiographs were obtained within 30 minutes of injection. The product showed adequate radio-opacity, retention time, diffusion and liquor miscibility. Minimal side effects both during and after the radiographic procedures were observed. Not one patient developed seizures, in spite of the use of anesthetic protocols that included either zolarepan-tiletamine or levomepromazin- zilazine- or diazepam-sodium thiopental. The presentation of the contrast medium in a multiple dose vial was considered an advantage, since it decreases losses and allows repeated sterilization in autoclave [pt

  10. Effects of computed tomography contrast medium factors on contrast enhancement

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi; Okuda, Itsuko

    2011-01-01

    The various nonionic iodinated contrast media used in contrast computed tomography (CT) studies differ in terms of their composition, characteristics, and iodine concentration (mgI/ml), as well as the volume injected (ml). Compared with ionic iodinated contrast media, nonionic iodinated contrast media are low-osmolar agents, with different agents having different osmotic pressures. Using a custom-made phantom incorporating a semipermeable membrane, the osmotic flow rate (hounsfield unit (HU)/s) could easily be measured based on the observed increase in CT numbers, and the relationship between the osmotic pressure and the osmotic flow rate could be obtained (r 2 =0.84). In addition, taking the effects of patient size into consideration, the levels of contrast enhancement in the abdominal aorta (AA) and inferior vena cava (IVC) were compared among four types of CT contrast medium. The results showed differences in contrast enhancement in the IVC during the equilibrium phase depending on the type of contrast medium used. It was found that the factors responsible for the differences observed in enhancement in the IVC were the osmotic flow rate and the volume of the blood flow pathways in the circulatory system. It is therefore considered that the reproducibility of contrast enhancement is likely to be reduced in the examination of parenchymal organs, in which scanning must be performed during the equilibrium phase, even if the amount of iodine injected per unit body weight (mgI/kg) is maintained at a specified level. (author)

  11. Radiculography with reduced amounts of contrast medium

    International Nuclear Information System (INIS)

    Signorini, E.; Caputo, N.; Chiurulla, C.; Ciorba, E.; Pelliccioli, G.P.; Cianciulli, E.

    1984-01-01

    Because of the frequency and seriousness of side effects observed after radiculography, due to, among the other things, the amount of contrast medium, the authors describe a method that gives diagnostically satisfactory results using a low dose of contrast and a tangent-beam technique. Among 106 patients undergoing radiculography with a tangent-beam technique and Iopamidol, only 4 developed mild side effects, namely headache in three cases and headache with nausea in one. (Author)

  12. Radiculography with water-soluble contraste medium

    International Nuclear Information System (INIS)

    Araujo Pinheiro, R.S. de

    1987-01-01

    The etiologic diagnosis of the lumbar pain is discussed. The radiculography with water-soluble contrast medium is used and 250 cases are studied. Some practical criteria of indication executation and interpretation of the examination are reported. (M.A.C.) [pt

  13. Contrast medium extravasation in intravenous urography

    Energy Technology Data Exchange (ETDEWEB)

    Tosch, U.; Becker-Gaab, C.; Hahn, D.

    1984-09-01

    Aetiology and diagnostic procedure of calyceal fornix rupture during intravenous urography are discussed. In the literature the fornix rupture is discribed as a spontaneous event - not so in the four cases presented. In two cases a sudden increase in intrapelvic pressure was due to an ureteric calculus, in the other cases an obstruction of the ureter was secondary to neoplasm. It is recommended to perform a CT as soon as a contrast medium extravasation in intravenous urography is diagnosed.

  14. Indirect MR venography: contrast medium protocols, postprocessing and combination in diagnosing pulmonary emboli with MRI; Indirekte MR-Phlebografie: Kontrastmittelprotokolle, Nachverarbeitung und Kombination mit Lungenemboliediagnostik in der MRT

    Energy Technology Data Exchange (ETDEWEB)

    Kluge, A.; Bachmann, G. [Diagnostische Radiologie, Kerckhoff-Klinik, Bad Nauheim (Germany); Rominger, M. [Diagnostische Radiologie, Phillips-Univ. Marburg (Germany); Schoenburg, M. [Herzchirurgie, Kerckhoff-Klinik, Bad Nauheim (Germany)

    2004-07-01

    Purpose: Integration of MR venography in a comprehensive MR imaging protocol in patients with suspected pulmonary embolism (PE) and evaluation of contrast media dosage, timing and postprocessing for diagnostic accuracy. Materials and Methods: Fortyeight consecutive inpatients with suspected PE or deep vein thrombosis were examined by MR venography according to one of the following protocols: protocol I: MR venography only, 0.25 mmol/kg bodyweight (BW) Gadopentate dimeglumine(Gd-DTPA) as single dose, bolus timing; protocol II: MR angiography of pulmonary arteries with a cumulative dosage of 0.25 mmol/kg contrast media, modification of coil setting for MR venography without further contrast media application; protocol III: as protocol II but with 0.125 mmol/kg BW, followed by MR venography. Signal-to-noise ratio, contrast-to-noise ratio, number of definable vascular segments and image quality were evaluated. The results were compared to conventional bilateral venography. Results: All MR venography examinations were of diagnostic quality and the examination time was below 10 min. MR venography could be performed in all 48 patients comparted to 43 of 48 patients for conventional venography. Significantly more superficial and deep veins of the leg could be visualized by MR venography (94% compared to 83% for conventional venography). Sensitivity and specificity were 100% and 92%, respectively. Quality differed significantly between 0.125 mmol/kg (protocol III) and 0.25 mmol/kg Gd-DTPA (protocols I and II) while timing did not influence quality (protocol I vs. II). (orig.) [German] Ziel: Integration der MR-Phlebografie in ein umfassendes Konzept der MRT-Diagnostik bei Verdacht auf Lungenembolie (LE). Untersuchung des Einflusses von Kontrastmittelmenge, -bolusform und Verzoegerungszeit sowie der Nachverarbeitung auf die diagnostische Qualitaet von MR-Phlebografien. Material und Methode: Bei 48 konsekutiven stationaeren Patienten mit Verdacht auf Beinvenenthrombose (TVT

  15. Does the application of gadolinium-DTPA have an impact on magnetic resonance phase contrast velocity measurements? Results from an in vitro study

    International Nuclear Information System (INIS)

    Heverhagen, J.T.; Hoppe, M.; Klose, K.-J.; Wagner, H.-J.

    2002-01-01

    Introduction/objective: To evaluate the potential influence of various concentrations of gadolinium (Gd)-DTPA on magnetic resonance phase contrast (MR PC) velocimetry. Material and methods: Imaging was done with a 1.0 T scanner using a standard Flash 2D sequence and a circular polarized extremity coil. In a validated flow phantom with a defined 75% area stenosis different concentrations of Gd-DTPA, diluted in a 10:1 water-yogurt mixture, MR PC measurements were correlated with a Doppler guide wire as gold standard. Results: MR PC measurements correlated well with the Doppler derived data (r=0.99; P 0.05; Student's t-test) flow measurement changes were noted (maximum pre-stenotic velocity: 21.3±1.3 cm/s; maximum intra-stenotic velocity: 84.0±3.6 cm/s). However, delineation of the perfused lumen was enhanced after the application of Gd-DTPA. Discussions and conclusion: The application of Gd-DTPA does not affect MR PC velocimetry. However, the application of contrast media allowed a more accurate vessel segmentation. MR PC measurements can be reliably carried out after application of Gd-DTPA

  16. Hepatocellular carcinoma on MR diffusion weighted imaging and dynamic contrast-enhanced imaging

    International Nuclear Information System (INIS)

    Dong Aisheng; Zuo Changjing; Tian Jianming; Lu Jianping; Wang Jian; Wang Li; Wang Fei

    2009-01-01

    Objective: To evaluate the findings of hepatocellular carcinoma (HCC) on DWI and dynamic Gd-DTPA-enhanced MR imaging. Methods: Eighty one patients with chronic hepatitis or liver cirrhosis underwent both DWI and dynamic Gd-DTPA-enhanced MRI studies of the liver for HCC detection. MR data of were retrospectively analyzed. Two observers determined in consensus the location and the number of focal lesions. The signal manifestation of the lesions on DWI and dynamic Gd-DTPA-enhanced MR imaging were analyzed. Results: DWI and Gd-DTPA-enhanced MR images detected 122 HCCs and 14 benign lesions. One hundred and sixteen HCCs (95.1%) showed hyperintensity on DWI and 6 HCCs in patients with severe cirrhosis showed isointensity. One hundred and five HCCs (86.1%) revealed hypointensity, 11 HCCs (9.0%) showed isointensity and 6 HCCs (4.9%) exhibited hyperintensity on T 1 weighted images. On Gd-DTPA-enhanced MR images, 101 HCCs(82.8%) were significantly enhanced on arterial phase and 99 HCCs showed hypointensity on portal and equilibrium phases. Twenty HCCs (16.4%), 18 of 20 less than 20 mm in diameter, showed isointensity on arterial phase and hyperintensity on DWI. Eight of 14 benign lesions showed hyperintensity and 6 isointensity on DWI. Five benign lesions with hypointensity on T 1 weighted images without contrast and hyperintensity on DWI showed no enhancement on Gd-DTPA-enhanced MR images; 6 benign lesions with isointensity on both T 1 weighted imaging without contrast and DWI exhibited avid enhancement on arterial phase and isointensty on portal and equilibrium phases; one of the two benign lesions, with isointensity before and after contrast images and hyperintentiy on DWI, was a regenerative nodule; another regenerative nodule with hyperintensity on both T 1 weighted images without contrast and DWI was greatly enhanced on arterial phase and showed isointensity on portal and equilibrium phases. Conclusions: Most of the HCCs were greatly enhanced on arterial phase on Gd-DTPA

  17. MRI enhancement of the facial nerve with Gd-DTPA, 2; Investigation of enhanced nerve portions in patients with facial palsy

    Energy Technology Data Exchange (ETDEWEB)

    Yanagida, Masahiro (Kansai Medical School, Moriguchi, Osaka (Japan))

    1993-08-01

    We performed enhanced MRI using Gd-DTPA in 84 patients with facial palsy. After assessing enhancement of the normal facial nerve, we examined enhancement in patients with Bell's palsy and Ramsay Hunt syndrome. In 95% of patients with Bell's palsy, enhancement was obtained in the distal IAC and labyrinthine portions. In 72%, enhancement was significant from the distal IAC portion through the vertical portion. In some of the patients who underwent enhanced MRI twice, increased signal intensity was observed in distal portions such as the vertical portion. In many cases of Ramsay Hunt syndrome, enhancement was seen extensively in the IAC portion through the vertical portion. In the subjects with internal auditory symptoms such as vertigo and tinnitus, enhancement of the IAC portion was seen not only in the facial nerve but also in the vestibular and the cochlear nerves. These results suggest that the vascular permeability of lesions in Bell's palsy may be increased from the distal IAC portion to the vertical portion. Judging from the present findings with Ramsay Hunt syndrome, symptoms related to the enhanced portions suggest that accompanying internal auditory symptoms occur due to inflammation of the IAC portions of cochlear and vestibular nerves. (author).

  18. Availability of Gd-DTPA enhanced MRI for lumbar disc herniation; Mechanism enhancing scar tissue around herniated disc and its meaning

    Energy Technology Data Exchange (ETDEWEB)

    Morita, Chisato; Yoshizawa, Hidezo; Nakai, Sadaaki; Kobayashi, Shigeru; Morita, Tomofumi; Kojima, Motohiro (Fujita Health Univ., Toyoake, Aichi (Japan))

    1994-05-01

    Extradural scar tissue arising between the herniated disk in the lumbar spine and its surrounding tissue was examined in 44 patients with lumbar disc herniation, using Gd-DTPA enhanced magnetic resonance imaging (MRI). Findings of enhanced MRI were divided into three types: that is, type 1 in which the surrounding of the herniated disk was not enhanced; type 2 in which it was partially enhanced; type 3 in which it was entirely enhanced. Of these 44 patients, 15 (34.1%) had type I, 22 (50.0%) had type 2 and 7 (15.9%) had type 3. Extradural scar tissue was seen as high signal intensity on T1-weighted images in 66%, revealing the extent of nerve root compression. Furthermore, 18 of the 44 patients underwent surgery and surgical findings were compared with types of MRI findings. According to MRI findings, these 18 patients consisted of 2 with type 1, 11 with type 2, and 5 with type 3. The two type 1 patients had subligamentous type; 9 type 2 patients had subligamentous type and the other 2 had transligamentous type; and the 5 type 3 patients had all sequestration type. Extradural scar tissue was microscopically shown to be composed of collagenic fibers containing many vessels and to be leakily neovascular structure associated with gap junction and fenestra. Enhanced MRI was capable of delineating the proliferation of extradural scar tissue surrounding the herniated disk easily, thus allowing the determination of pathological changes arising between the herniated disc and nerve root. (N.K.).

  19. Contrast medium-induced nephropathy: the pathophysiology

    DEFF Research Database (Denmark)

    Persson, P B; Tepel, Martin

    2006-01-01

    A widespread, rather general, definition of contrast-induced nephropathy (CIN) is an impairment in renal function occurring within 3 days following the intravascular administration of contrast media (CM) and the absence of an alternative aetiology. In spite of the vast clinical importance of CIN...... the current knowledge of the mechanisms causing CIN, it is not possible to recommend a certain class of contrast media, except to avoid large doses of CM of the first generation. From a pathophysiological perspective, volume expansion is effective in avoiding CIN, since water permeability of the collecting...

  20. Dural invasion of meningiomas adjacent to the tumor margin on Gd-DTPA-enhanced MR images: histopathologic correlation

    International Nuclear Information System (INIS)

    Hutzelmann, A.; Palmie, S.; Freund, M.; Heller, M.; Buhl, R.

    1998-01-01

    In intracranial meningiomas a flat, contrast-enhancing, dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA-enhanced MR images. We wished to evaluate whether there is a correlation between MR images and meningeal invasion of intracranial meningiomas. The study included 54 patients with intracranial meningioma and the meningeal sign. MR studies included T2-weighted and gadolinium-DTPA-enhanced T1-weighted images in axial, coronal, and sagittal planes. Histopathologic examinations were done on the meningiomas adjacent to the dura mater. The meningeal sign on MRI was observed from 2 up to 35 mm from the main tumor mass in 31 (57 %) of the 54 patients. In 20 of these 31 the histopathologic examination showed tumor invasion, while 11 patients had no tumor invasion but tissue proliferation, hypervascularity, and vascular dilatation. Seven of the 23 meningiomas without the meningeal sign had histologically proven infiltration of the adjacent dura. MR imaging is not able to determine definitive whether or not there is dural infiltration of the meningiomas. In conclusion, resection of the tumor with a wide margin is necessary to achieve complete excision of meningioma and to avoid recurrence. (orig.)

  1. Contrast MR imaging of acute cerebral infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kogame, Saeko; Syakudo, Miyuki; Inoue, Yuichi (Osaka City Univ. (Japan). Faculty of Medicine) (and others)

    1992-04-01

    Thirty patients with acute and subacute cerebral infarction (13 and 17 deep cerebral infarction) were studied with 0.5 T MR unit before and after intravenous injection of Gd-DTPA. Thirteen patients were studied within 7 days after neurological ictus, 17 patients were studied between 7 and 14 days. Two types of abnormal enhancement, cortical arterial and parenchymal enhancement, were noted. The former was seen in 3 of 4 cases of very acute cortical infarction within 4 days after clinical ictus. The latter was detected in all 7 cases of cortical infarction after the 6th day of the ictus, and one patient with deep cerebral infarction at the 12th day of the ictus. Gd-DTPA enhanced MR imaging seems to detect gyral enhancement earlier compared with contrast CT, and depict intra-arterial sluggish flow which was not expected to see on contrast CT scans. (author).

  2. Estimating kinetic parameters from dynamic contrast-enhanced T(1)-weighted MRI of a diffusable tracer: standardized quantities and symbols

    DEFF Research Database (Denmark)

    Tofts, P.S.; Brix, G; Buckley, D.L.

    1999-01-01

    We describe a standard set of quantity names and symbols related to the estimation of kinetic parameters from dynamic contrast-enhanced T(1)-weighted magnetic resonance imaging data, using diffusable agents such as gadopentetate dimeglumine (Gd-DTPA). These include a) the volume transfer constant K...

  3. Histamine release and endothelial leakage from an intravascular contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Raininko, R.

    1981-04-01

    The endothelial injury produced by meglumine iodamide was studied in the rat aorta. A mixture of blood and contrast medium was more toxic to the endothelium than the pure contrast agent. This difference disappeared after premedication with antihistamine, which did not affect the injury produced by the pure contrast agent. Meglumine iodamide appears to cause a release of histamine from blood but not from the aortic endothelium nor from surrounding tissues in amounts demonstrable by this method. Leucocytes are a source of histamine after intravascular contrast medium administration.

  4. Distinctive radiological features of small hand joints in rheumatoid arthritis and seronegative spondyloarthritis demonstrated by contrast-enhanced (Gd-DTPA) magnetic resnance imaging

    International Nuclear Information System (INIS)

    Jevtic, V.; Watt, I.; Rozman, B.; Kos-Golja, M.; Demsar, F.; Jarh, O.

    1995-01-01

    A series of patients with clinically early inflammatory joint disease due to rheumatoid arthritis, psoriatic arthritis and Reiter's syndrome were examined by plain film radiography and magnetic resonance imaging (MRI). The spin echo T1-weighted precontrast, T2-weighted, and, especially, T1-weighted postcontrast images demonstrated distinct differences in the distribution of inflamatory changes, both within and adjacent to involved small hand joints. Two major subtypes of inflammatory arthritis were shown, thus providing a specific differential diagnosis between rheumatoid arthritis and some patients with seronegative spondyloarthritis. In particular, all the patients with Reiter's syndrome who were studied, and half of those with psoriatic arthritis, had a distinctive pattern of extra-articular desease involvement. The need for a new classification of clinical subsets in psoriatic arthritis has been recently suggested. The present findings suggest that magnetic resonance imaging could be useful in such a reclassification of seronegative spondyloarthritis, as well as offering considerable potential for a reappraisal of pathogenesis and therapy. In this series, it was also noted that juxta-articular osteoporosis on plain film did not correlate with bone marrow oedema on MRI. Hence the aetiology of this common radiographic finding also merits further consideration. (orig.)

  5. Oral gadopentetate dimeglumine administration as a negative gastrointestinal contrast agent to improve image quality of MR cholangiopancreatography

    International Nuclear Information System (INIS)

    Chen Yi; Xu Yikai; Zhao Yuhui; Wang Guisheng

    2008-01-01

    Objective: To choose optimal concentration and volume of Gd-DTPA solution as a oral gastrointestinal negative contrast agent for MRCP. To evaluate the role of Gd-DTPA solution in improving image quality of MRCP. Methods: In vitro experiment: Gd-DTPA solution was made with different concentrations. T 1 WI, T 2 WI, two-dimensional single slice fast spin echo sequence and three-dimensional half-fourier acquisition single-shot fast spin echo sequence were performed to measure the signal intensity of these contrast agents respectively, so Gd-DTPA solution with the optimal concentration can be decided as oral negative gastrointestinal contrast agent on MRCP. Clinical study: The Gd-DTPA solution with optimal concentration and volume was regarded as an oral negative gastrointestinal contrast agent of MRCP. Twenty- four' patients were performed with MRCP before and after (5-10 minutes and 10-15 minutes) administration of oral negative gastrointestinal contrast agent and image quality was analyzed. Statistical analysis was performed using analysis of variance with SPSS 10.0. Results: When the concentration of Gd-DTPA solution was ≤0.01 mol/L, the contrast agent was hyperintense on T 1 WI. On T 2 WI, when the concentration was ≥0.015 mol/L, it was as hypointense as basic ground; On 2D FSE MRCP images, controls were hyperintense and the contrast agent with concentration ranging from 0.0025 mol/L to 0.03 mol/L was hypointense. On 3D HEAST MRCP image, controls were hyperintense and when the concentration of Gd-DTPA was ≥0.01 mol, the contrast agent was hypointense. The Gd-DTPA solution with the concentration of 0.01 mol/L and the volume of 100 ml was chosen as MRCP oral negative gastrointestinal contrast agent. On MRCP images after oral administration of the contrast agent, in 10-15 minutes, the average grade scores within 24 patients of the intrahepatic bile duct, the common hepatic bile duct, the gall bladder, the common bile duct and pancreatic duct (the average grade

  6. Macromolecular and dendrimer-based magnetic resonance contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Bumb, Ambika; Brechbiel, Martin W. (Radiation Oncology Branch, National Cancer Inst., National Inst. of Health, Bethesda, MD (United States)), e-mail: pchoyke@mail.nih.gov; Choyke, Peter (Molecular Imaging Program, National Cancer Inst., National Inst. of Health, Bethesda, MD (United States))

    2010-09-15

    Magnetic resonance imaging (MRI) is a powerful imaging modality that can provide an assessment of function or molecular expression in tandem with anatomic detail. Over the last 20-25 years, a number of gadolinium-based MR contrast agents have been developed to enhance signal by altering proton relaxation properties. This review explores a range of these agents from small molecule chelates, such as Gd-DTPA and Gd-DOTA, to macromolecular structures composed of albumin, polylysine, polysaccharides (dextran, inulin, starch), poly(ethylene glycol), copolymers of cystamine and cystine with GD-DTPA, and various dendritic structures based on polyamidoamine and polylysine (Gadomers). The synthesis, structure, biodistribution, and targeting of dendrimer-based MR contrast agents are also discussed

  7. Synergistic enhancement of iron oxide nanoparticle and gadolinium for dual-contrast MRI

    International Nuclear Information System (INIS)

    Zhang, Fan; Huang, Xinglu; Qian, Chunqi; Zhu, Lei; Hida, Naoki; Niu, Gang; Chen, Xiaoyuan

    2012-01-01

    Highlights: ► MR contrast agents exert influence on T 1 or T 2 relaxation time of the surrounding tissue. ► Combined use of iron oxide and Gd-DTPA can improve the sensitivity/specificity of lesion detection. ► Dual contrast MRI enhances the delineation of tumor borders and small lesions. ► The effect of DC-MRI can come from the high paramagnetic susceptibility of Gd 3+ . ► The effect of DC-MRI can also come from the distinct pharmacokinetic distribution of SPIO and Gd-DTPA. -- Abstract: Purpose: The use of MR contrast agents allows accurate diagnosis by exerting an influence on the longitudinal (T 1 ) or transverse (T 2 ) relaxation time of the surrounding tissue. In this study, we combined the use of iron oxide (IO) particles and nonspecific extracellular gadolinium chelate (Gd) in order to further improve the sensitivity and specificity of lesion detection. Procedures: With a 7-Tesla scanner, pre-contrasted, IO-enhanced and dual contrast agent enhanced MRIs were performed in phantom, normal animals, and animal models of lymph node tumor metastases and orthotopic brain tumor. For the dual-contrast (DC) MRI, we focused on the evaluation of T 2 weighted DC MRI with IO administered first, then followed by the injection of a bolus of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA). Results: Based on the C/N ratios and MRI relaxometry, the synergistic effect of coordinated administration of Gd-DTPA and IO was observed and confirmed in phantom, normal liver and tumor models. At 30 min after administration of Feridex, Gd-DTPA further decreased T 2 relaxation in liver immediately after the injection. Additional administration of Gd-DTPA also immediately increased the signal contrast between tumor and brain parenchyma and maximized the C/N ratio to −4.12 ± 0.71. Dual contrast MRI also enhanced the delineation of tumor borders and small lesions. Conclusions: DC-MRI will be helpful to improve diagnostic accuracy and decrease the threshold size for

  8. Accuracy of axillary MR imaging in treated breast cancer for distinguishing between recurrent tumour and treatment effects: Does intravenous Gd-DTPA enhancement help in cases of diagnostic dilemma?

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, Alison J.; Carrington, Bernadette M.; Hammond, Claire L.; Swindell, Rick; Magee, Brian

    2000-12-01

    AIM: To evaluate the sensitivity and specificity of axillary magnetic resonance imaging (MRI) in symptomatic patients, who had previously been treated for breast cancer, compared with clinical outcome after a minimum of 1 year. METHODS: One hundred and five patients underwent axillary MRI examinations and were diagnosed as axillary tumour, metastatic tumour, treatment effect or normal. RESULTS: At MRI, 48 patients had axillary tumour, 51 had metastatic tumour (37 had both), 27 had treatment effect and 22 were normal. At outcome (median follow-up, 484 days), 54 patients were positive for axillary tumour, 59 for metastatic disease (40 had both), 21 had treatment effect alone and 18 were clear. Magnetic resonance imaging showed 89% sensitivity, 100% specificity and 94% accuracy for recurrent axillary tumour, and 85% sensitivity, 98% specificity and 90% accuracy for metastatic tumour. Soft tissue plaques were the commonest axillary disease pattern seen (37). Small volume soft tissue plaques gave the most diagnostic difficulty. Non-dynamic enhancement with intravenous Gadopentetate dimeglumine (Gd-DTPA) in a subset of 34 patients improved sensitivity for axillary tumour from 40 to 74%, and improved diagnostic confidence in 11 patients (32%). Magnetic resonance imaging had a positive management impact leading to treatment alteration in 45 patients, 43 of whom had recurrent axillary and/or metastatic tumour. CONCLUSIONS: Tumour plaques were the commonest pattern of recurrent axillary disease. Forty-eight percent of the patients had metastatic deposits identified by MRI. Magnetic resonance imaging had excellent specificity (100%) and good sensitivity (89%) for recurrent axillary tumour compared with outcome at 1 year, which was improved by non-dynamic administration of Gd-DTPA in 32% of the subset who received it. Bradley, A.J. (2000)

  9. Development of a conjugated gadolinium and cisplatin-gelatin possessing properties as an intravascular contrast agent for MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Sonoda, Akinaga [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: akinagasonoda@yahoo.co.jp; Nitta, Norihisa [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: r34nitta@yahoo.co.jp; Ohta, Shinichi [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: junryuhei@belle.shiga-med.ac.jp; Seko, Ayumi [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: sekoayumi@yahoo.co.jp; Jo, Jun-ichiro [Department of Biomaterials, Institute for Frontier Medical Sciences, Kyoto University, 53 Kawara-cho Shogoin, Sakyo-ku, Kyoto 606-8501 (Japan)], E-mail: jo@frontier.kyoto-u.ac.jp; Morikawa, Shigehiro [Biomedical MR Science Research Center, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: morikawa@belle.shiga-med.ac.jp; Tabata, Yasuhiko [Department of Biomaterials, Institute for Frontier Medical Sciences, Kyoto University, 53 Kawara-cho Shogoin, Sakyo-ku, Kyoto 606-8501 (Japan)], E-mail: yasuhiko@frontier.kyoto-u.ac.jp; Takahashi, Masashi [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: masashi@belle.shiga-med.ac.jp; Murata, Kiyoshi [Department of Radiology, Shiga University of Medical Science, Setatsukinowa-cho, Otsu, Shiga 520-2192 (Japan)], E-mail: murata@belle.shiga-med.ac.jp

    2009-09-15

    Purpose: The purpose of this study is to create a Gd-DTPA-Gel-Cis compound, which made from gadolinum (Gd), diethylenetriaminepentaacetic acid (DTPA)-dianhydride, cis-diamminedichloroplatinum (Cis) and bovine gelatin (Gel), that makes it possible to visualize Cis as intravascular agent under magnetic resonance imaging (MRI). Materials and methods: The amount of DTPA, Gd, and Cis were titrated to determine the new compound's conjugation ratio with gelatin. Considering these functions, Gd-DTPA-Gel-Cis was synthesized, and its stability in bovine serum was evaluated. In addition, the signal intensity of the diluted sample was measured under 1.5 Tesla MRI. Results: The synthesized 10 mg/ml of Gd-DTPA-Gel-Cis contained 42.84 {mu}g/ml of Gd and 1.53 {mu}g/ml of platinum. Gd-DTPA-Gel-Cis (100 mg/10 ml) enclosed into the cellulose dialysis tubing was placed in 90 ml of bovine serum and shaken reciprocally at 72 stroke/min at 37 deg. C. Partial release of free Pt was shown at 6 and 24 h, but no release of Gd occurred for a 24-h period. And high stability of Gd conjugated to DTPA-Gel-Cis. This result suggests possible anti-tumor effectiveness and high stability of Gd conjugated to DTPA-Gel-Cis. The diluted sample presented high signal intensity under 1.5 Tesla MRI. Conclusion: Gd-DTPA-Gel-Cis has been developed successfully and we have proven its stability and contrast ability in MRI.

  10. Contrast-enhanced 3D MR DSA for intracranial vessels

    Energy Technology Data Exchange (ETDEWEB)

    Tominaga, Satoru; Ishikura, Reiichi; Ando, Kumiko; Morikawa, Tsutomu; Nakao, Norio [Hyogo Coll. of Medicine, Nishinomiya (Japan); Ikeda, Jyota

    1999-12-01

    We performed serial scans of ultrafast 3D MR angiography sequence which was improved to shorten acquisition time by means of zero-filling interpolation after injection of the contrast medium and called it contrast-enhanced three-dimensional (3D) magnetic resonance (MR) digital subtraction angiography (DSA). The parameters were 3.8/1.3/35 (TR/TE/flip angle), a slab thickness of 60 mm, a voxel size of 2.3 x 1.2 x 3.7 mm, a scan time of 2.9 s. The measurement was sequentially performed for 10 to 15 times after administration of 0.1 mmol/kg of Gd-DTPA. Total acquisition time was almost 30 to 45 s. All images of each set were subtracted with precontrast images and then the maximum intensity projection (MIP) were performed. In all cases, contrast-enhanced 3D MR DSA could clearly depict sequential change of the cranial vessels from the arterial phase to the venous phase. The view from different angle on any phase could be obtained and stereoscopic view was possible. The time intensity curve was obtained from signal intensity measured on the source images. The combination of conventional 3D TOF MRA with contrast-enhanced 3D MR DSA was the useful study which could replace cerebral angiography. (author)

  11. Potential mechanisms behind contrast medium-induced nephropathy

    African Journals Online (AJOL)

    How contrast medium-induced nephropathy (CIN) comes about is poorly understood, although CIN is a common cause of acute renal failure. Hitherto, the various studies performed have led to different interpretations and partially contradictory conclusions. This article aimed to review the mechanisms underlying CIN and to ...

  12. Extravasation of contrast medium during CT examination: An ...

    African Journals Online (AJOL)

    Introduction: extravasation is an adverse reaction to intravenous injection of contrast medium (CM) during CT examination. The objectives of this study are to determine the frequency, management and outcomes of extravasations and to assess risk factors for extravasation. Methods: every incident of extravasation which ...

  13. Post-contrast acute kidney injury - Part 1: Definition, clinical features, incidence, role of contrast medium and risk factors : Recommendations for updated ESUR Contrast Medium Safety Committee guidelines.

    Science.gov (United States)

    van der Molen, Aart J; Reimer, Peter; Dekkers, Ilona A; Bongartz, Georg; Bellin, Marie-France; Bertolotto, Michele; Clement, Olivier; Heinz-Peer, Gertraud; Stacul, Fulvio; Webb, Judith A W; Thomsen, Henrik S

    2018-02-09

    The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 2011 guidelines on the prevention of post-contrast acute kidney injury (PC-AKI). The results of the literature review and the recommendations based on it, which were used to prepare the new guidelines, are presented in two papers. AREAS COVERED IN PART 1: Topics reviewed include the terminology used, the best way to measure eGFR, the definition of PC-AKI, and the risk factors for PC-AKI, including whether the risk with intravenous and intra-arterial contrast medium differs. • PC-AKI is the preferred term for renal function deterioration after contrast medium. • PC-AKI has many possible causes. • The risk of AKI caused by intravascular contrast medium has been overstated. • Important patient risk factors for PC-AKI are CKD and dehydration.

  14. Noncontrast and contrast enhanced MR imaging in the evaluation of partial ureteral obstruction: An experimental study in the micropig

    Energy Technology Data Exchange (ETDEWEB)

    Thurnher, S.; Tzika, A.A.; Hricak, H.; Mattei, P.; Aboseif, S.; Engelstad, B.; Price, D.C. (Univ. of California School of Medicine, San Francisco (USA))

    1989-07-01

    Twelve Yucatan micropigs (3 controls; 3 sham-operated; 6 with unilateral obstruction) were studied to assess the value of noncontrast and contrast-enhanced (Gadolinium-DTPA) magnetic resonance (MR) imaging in the evaluation of partial ureteral obstruction. MR findings were correlated with findings of quantitative (Tc-99m-DMSA) scintigraphy, and histology. On noncontrast T1-weighted images, the normal porcine kidney demonstrated good corticomedullary contrast (CMC = 16.8% +/- 5.0). Five minutes after administration of Gd-DTPA, there was enhancement of the renal cortex (+24.4%) and medulla (+46.2%), and CMC was no longer discernible. Enhancement of the urine within the collecting system (+119.1%) was also observed. The obstructed kidneys demonstrated marked thinning of the renal parenchyma and decreased signal intensity on noncontrast T1- and T2-weighted images (P less than 0.01). Urine in the dilated collecting system did not differ significantly from urine in controls except in the three animals with urinary tract infection (P less than 0.05). Five minutes following injection of Gd-DTPA, there was enhancement of the renal parenchyma in all kidneys. Excretion was seen in three pigs and no excretion in two. Thus, useful information can be obtained in partial ureteral obstruction from both pre-contrast and Gd-DTPA-enhanced MR images of the kidney.

  15. Quantification of the effect of water exchange in dynamic contrast MRI perfusion measurements in the brain and heart

    DEFF Research Database (Denmark)

    Larsson, H B; Rosenbaum, S; Fritz-Hansen, T

    2001-01-01

    Measurement of myocardial and brain perfusion when using exogenous contrast agents (CAs) such as gadolinium-DTPA (Gd-DTPA) and MRI is affected by the diffusion of water between compartments. This water exchange may have an impact on signal enhancement, or, equivalently, on the longitudinal......(i)) by using a realistic simulation. These results were verified by in vivo studies of the heart and brain in humans. The conclusion is that water exchange between the vascular and extravascular extracellular space has no effect on K(i) estimation in the myocardium when a normal dose of Gd-DTPA is used. Water...... relaxation rate, and could therefore cause a systematic error in the calculation of perfusion (F) or the perfusion-related parameter, the unidirectional influx constant over the capillary membranes (K(i)). The aim of this study was to quantify the effect of water exchange on estimated perfusion (F or K...

  16. Hypersensitivity reactions and contrast medium injection: Are they always related?

    Energy Technology Data Exchange (ETDEWEB)

    Boehm, Ingrid, E-mail: i.boehm@uni-bonn.de [Department of Radiology, Philipps University of Marburg, Baldingerstrasse, 35039 Marburg (Germany); Alfke, Heiko [Department of Radiology, Klinikum Luedenscheid, Luedenscheid (Germany); Klose, Klaus Jochen [Department of Radiology, Philipps University of Marburg, Baldingerstrasse, 35039 Marburg (Germany)

    2011-11-15

    Background: Hypersensitivity (allergic or non-allergic) reactions that occur after contrast medium (CM) injection are usually related to the CM. Recent studies, and case reports lack the analysis of alternate causes that could be also responsible in individual cases. Patients and methods: We investigated the individual relevant factor/causative agent of adult patients with hypersensitivity reactions that occurred in radiological units during CM-enhanced procedures (CT, angiography, urography, or MR-examinations). Both immediate and non-immediate (delayed) reactions were included. To find out the relevant agent a detailed patients' history was carefully analyzed. In addition, the records were retrospectively reviewed, and if indicated and possible laboratory (e.g. basophil activation test) and skin tests (e.g. prick) and/or provocations with CM-injections under routine conditions were performed. Results: 38 patients (men n = 21) suspected for CM-hypersensitivity reactions were identified. These reactions were in most cases mild (n = 21), moderate reactions occurred in 13 cases, and four patients had severe reactions. In 28 patients the reactions were induced by the CM (iodinated CM in 25 cases). Four patients had reactions that were not CM-related (latex allergy, adenosine reaction, vasovagal reaction, unknown cause) and in six cases the reaction was partly CM-related (immunological activation was present due to the patients' diseases). Conclusion: Our data support the hypothesis that in CM-enhanced procedures not only contrast materials but also a broad range of other factors may also induce hypersensitivity reactions. Therefore, the number of CM-induced hypersensitivity is smaller than initially suspected. The knowledge of the cause of a reaction is essential to effectively prevent its recurrence and to improve safety aspects in patients undergoing CM-injection. Larger trials should be performed to more specifically assess alternate causes in patients

  17. Angio-RM das artérias carótidas e vertebrais: análise de diferentes técnicas de volume e diluição de contraste em aparelho de 1,0 t e gradiente de 15 mt/m Contrast-enhanced MR angiography of the carotid and vertebral arteries: analysis of different contrast volumes and dilution techniques at 1.0 T with 15 mT/m gradient.

    Directory of Open Access Journals (Sweden)

    Luiz Guilherme C. Hartmann

    2001-08-01

    Full Text Available OBJETIVO: Avaliar as artérias cervicais (carótidas e vertebrais por meio da angio-RM, utilizando-se diferentes dosagens e diluições de contraste paramagnético. MATERIAIS E MÉTODOS: Estudo prospectivo em 15 pacientes, com análise de 30 artérias carótidas comuns, 30 artérias carótidas internas, 30 artérias carótidas externas e 30 artérias vertebrais, utilizando-se diferentes volumes e dosagens de contraste paramagnético: grupo I - dose única (14 ml de Gd-DTPA; grupo II -dose dupla (28 ml de Gd-DTPA; grupo III - dose única e diluída a 50%. A injeção de contraste foi realizada com a utilização de bomba injetora e com velocidades de injeção de 2 ml/s (grupo I e 3 ml/s (grupos II e III. Os segmentos arteriais foram analisados por três examinadores em consenso de forma subjetiva, avaliando-se o grau de visibilidade, intensidade de contrastação e definição de seus contornos. RESULTADOS: Em todos os itens analisados os pacientes do grupo II apresentaram melhor resultado (visibilização total, boa contrastação dos vasos e contornos bem definidos. No grupo I houve boa visibilização das artérias carótidas e vertebrais, porém a intensidade de contraste e a definição dos contornos apresentaram variabilidade qualitativa. O grupo III apresentou os piores resultados, com dificuldade de visibilização, intensidade de contrastação baixa e contornos mal definidos. CONCLUSÃO: Entre os grupos analisados, a técnica utilizando dose dupla de gadolínio é a que permite melhor avaliação das artérias cervicais. A utilização de contraste diluído prejudica a avaliação dos vasos do pescoço.PURPOSE: To evaluate the carotid and vertebral arteries by magnetic resonance angiography, using different contrast volumes and dilution techniques. SUBJECTS AND METHODS: Prospective study of 15 patients, which included the evaluation of 30 common carotid arteries, 30 internal carotid arteries, 30 external carotid arteries and 30

  18. Patient radiation dose during fluoroscopy testes with contrast medium

    International Nuclear Information System (INIS)

    Darsalih, Abir Abdelrady El noor

    2016-09-01

    The purpose of this study was to assess the patient radiation dose received in fluoroscopy examinations during contrast medium. The cumulative air kerma (Ck), kerma area product (KAP) and fluoroscopy time were measured for sixty ( male and female ) patients undergoing five fluoroscopy examinations KAP metre which was installed for the purpose of this study. The mean kerma area product were found to be 2.681, 5.1561, 9.85529. 5.7974 and 13.09 Gy.cm 2 for HSG, A.S and D.S, GI Track and sonogram tests, respectively. The obtained mean cumulative dose was were 6.31, 13.88, 24.61, 22.56 and 32.14 mGy for HSG, A.S, A.S and D.S , GI Track, respectively, the mean fluoroscopy time were. 0.18, 0.51,0.89,1.57 and 1.75 min, for HSG, A.S, A.S, and D.S, G1 Track and sonogram test respectively. Patient dose is mainly dependent on the patient size, procedure, equipment used exposure factor and user experience. As KV and mA were controlled by the AEC and it was found to be well calibrated, possible optimization could be achieved by radiologist by decreasing the exposure time if possible. (Author)

  19. Improve identification of details in double-contrast examination of the stomach by means of a new contrast medium mixture

    International Nuclear Information System (INIS)

    Tenner, R.

    1984-01-01

    In a contrast medium study, 100 patients were employed for a comparison between the contrast medium Mikropaque liquid and a mixture of Mikropaque HD and Mikropaque liquid in double-contrast examination of the stomach. The special feature of this method was that one and the same stomach was examined in each case with both contrast media. The new contrast media mixture with Mikropaque HD represents a step forward; the contrast could be enhanced in 80% of the cases, and the finely contoured relief became visible in two-thirds of the cases, compared with one-third of the examined patients before this method was introduced. (orig.) [de

  20. Contrast medium-induced nephropathy: Aspects on incidence ...

    African Journals Online (AJOL)

    Contrast media-induced nephropathy (CIN) is a well-known complication of radiological examinations employing iodine contrast media (I-CM). The rapid development and frequent use of coronary interventions and multi-channel detector computed tomography with concomitant administration of relatively large doses of ...

  1. Gadolinium-porphyrins: new potential magnetic resonance imaging contrast agents for melanoma detection

    OpenAIRE

    Daryoush Shahbazi-Gahrouei

    2006-01-01

    BACKGROUND: Two new porphyrin-based magnetic resonance imaging (MRI) contrast agents, Gd-hematoporphyrin (Gd-H) and Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd-TCP) were synthesized and tested in nude mice with human melanoma (MM-138) xenografts as new melanoma contrast agents. METHODS: Subcutaneous xenografts of human melanoma cells (MM-138) were studied in 30 (five groups of six) nude mice. The effect of different contrast agents (Gd-TCP, Gd-H, GdCl3 and Gd-DTPA) on proton relaxatio...

  2. The clinical use of contrast agents in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Bydder, G.M.

    1987-01-01

    Interest in the use of external agents to increase tissue contrasts has come from many sources dating back to the earliest work in NMR, to animal studies and to the widespread use of contrast agents in conventional radiological practice. The first clinical magnetic resonance images were published in 1980 and in the following year a brief account of the use of the paramagnetic agents in human volunteers was established. It was apparent relatively early in the development of magnetic resonance imaging (MRI) that a high level of soft tissue contrast was available de novo and the need for externally administered agents might therefore be small. This observation was tempered by the fact that separation of tumour from oedema was frequently better with contrast enhanced CT X-ray than with unenhanced MRI and that of a contrast agent might therefore be needed for MRI. At the end of 1983 the first parenteral agent gadoliminum diethylene triamine pentaacetic acid (Gd-DTPA) was used in volunteers and clinical studies began in 1984. At the present time only molecular O/sub 2/, oral iron compounds and Gd-DTPA are in clinical use although there are a number of other agents which have been used in animals and some of these may become available for clinical use in the foreseeable future

  3. Gadolinium-porphyrins: new potential magnetic resonance imaging contrast agents for melanoma detection

    Directory of Open Access Journals (Sweden)

    Daryoush Shahbazi-Gahrouei

    2006-11-01

    Full Text Available BACKGROUND: Two new porphyrin-based magnetic resonance imaging (MRI contrast agents, Gd-hematoporphyrin (Gd-H and Gd-tetra-carboranylmethoxyphenyl-porphyrin (Gd-TCP were synthesized and tested in nude mice with human melanoma (MM-138 xenografts as new melanoma contrast agents. METHODS: Subcutaneous xenografts of human melanoma cells (MM-138 were studied in 30 (five groups of six nude mice. The effect of different contrast agents (Gd-TCP, Gd-H, GdCl3 and Gd-DTPA on proton relaxation times was measured in tumors and other organs. T1 values, signal enhancement and the Gd concentration for different contrast agent solutions were also investigated. RESULTS: The porphyrin agents showed higher relaxivity compared to the clincal agent, Gd-DTPA. A significant 16% and 21% modification in T1 relaxation time of the water in human melanoma tumors grafted in the nude mice was revealed 24 hours after injection of Gd-TCP and Gd-H, respectively. The percentage of injected Gd localized to the tumor measured by inductively coupled plasma atomic emission spectrometry (ICP-AES was approximately 21% for Gd-TCP and 28% for Gd-H which were higher than that of Gd-DTPA (10%. CONCLUSIONS: The high concentration of Gd in the tumor is indicative of a selective retention of the compounds and indicates that Gd-TCP and Gd-H are promising MR imaging contrast agents for melanoma detection. Gd-porphyrins have considerable promise for further diagnostic applications in magnetic resonance imaging. KEY WORDS: MRI, porphyrin-based contrast agent, hematoporphyrin, melanoma.

  4. Allergic reaction to contrast medium following gastric band adjustment.

    Science.gov (United States)

    Dewachter, Pascale; Mouton-Faivre, Claudie

    2007-10-01

    Bariatric surgery is increasingly performed for effective weight loss. A morbidly obese 27-year-old woman underwent laparoscopoic adjustable gastric banding. After a postoperative adjustment of the stomal diameter of the band with ioxaglate, she presented an immediate hypersensitivity reaction. With the patient's consent, cutaneous tests to contrast agents used during the procedure and to latex were performed. Allergy to ioxaglate was confirmed by skin-test positivity. This case suggests the need for allergological investigation of drugs/substances administered during the perioperative period, in case of hypersensitivity reaction.

  5. Effects of gadolinium-based contrast agents on thyroid hormone receptor action and thyroid hormone-induced cerebellar Purkinje cell morphogenesis

    Directory of Open Access Journals (Sweden)

    Noriyuki Koibuchi

    2016-08-01

    Full Text Available Gadolinium (Gd-based contrast agents (GBCAs are used in diagnostic imaging to enhance the quality of magnetic resonance imaging or angiography. After intravenous injection, GBCAs can accumulate in the brain. Thyroid hormones (THs are critical to the development and functional maintenance of the central nervous system. TH actions in brain are mainly exerted through nuclear TH receptors (TRs. We examined the effects of GBCAs on TR-mediated transcription in CV-1 cells using transient transfection-based reporter assay and thyroid hormone-mediated cerebellar Purkinje cell morphogenesis in primary culture. We also measured the cellular accumulation and viability of Gd after representative GBCA treatments in cultured CV-1 cells. Both linear (Gd-diethylene triamine pentaacetic acid-bis methyl acid, Gd-DTPA-BMA and macrocyclic (Gd-tetraazacyclododecane tetraacetic acid, Gd-DOTA GBCAs were accumulated without inducing cell death in CV-1 cells. In contrast, Gd chloride (GdCl3 treatment induced approximately 100 times higher Gd accumulation and significantly reduced the number of cells. Low doses of Gd-DTPA-BMA (10−8–10−6 M augmented TR-mediated transcription, but the transcription was suppressed at higher dose (10−5 – 10−4 M, with decreased β-galactosidase activity indicating cellular toxicity. TR-mediated transcription was not altered by Gd-DOTA or GdCl3, but the latter induced a significant reduction in β-galactosidase activity at high doses, indicating cellular toxicity. In cerebellar cultures, the dendrite arborization of Purkinje cells induced by 10-9 M T4 was augmented by low-dose Gd-DTPA-BMA (10−7 M but was suppressed by higher dose (10−5 M. Such augmentation by low-dose Gd-DTPA-BMA was not observed with 10-9 M T3, probably because of the greater dendrite arborization by T3; however, the arborization by T3 was suppressed by a higher dose of Gd-DTPA-BMA (10-5 M as seen in T4 treatment. The effect of Gd-DOTA on dendrite arborization

  6. Renal clearance of an ionic high-osmolar and a nonionic low-osmolar contrast medium

    International Nuclear Information System (INIS)

    Thomsen, H.S.; Vestergaard, A.; Nielsen, S.L.; Fogh-Andersen, N.; Golman, K.; Dorph, S.

    1991-01-01

    One hundred patients with normal serum creatinine concentration underwent intravenous urography with either an ionic high-osmolar (diatrizoate) or a nonionic low-osmolar (iopamidol) contrast medium after randomization. Before injection of the contrast medium, a blood sample was drawn for determinating serum creatinine concentration, and a urine sample for measurement of urine osmolality. Using x-ray fluorescence, the plasma concentration of iodine (contrast medium) was determined on blood samples drawn approximately 3 and 4 hours after injection of the contrast medium. The glomerular filtration rate was calculated by two different formulas: one requiring only a single sample and one requiring at least two samples (standard). There were poor correlations between the standard contrast medium clearance and the serum creatinine concentration, the estimated creatinine clearance (calculated from a nomogram), as well as the urine osmolality. The 3-hour and the 4-hour single-sample values correlated well with the two-sample values for both contrast media. In patients with normal serum creatinine, the glomerular filtration rate determined by measuring the contrast medium concentration in a single plasma sample obtained at 3 hours, is almost identical to the value determined from two samples. Consequently, two samples are unnecessary

  7. An Individually Optimized Protocol of Contrast Medium Injection in Enhanced CT Scan for Liver Imaging

    Directory of Open Access Journals (Sweden)

    Shi-Ting Feng

    2017-01-01

    Full Text Available Objective. To investigate the effectiveness of a new individualized contrast medium injection protocol for enhanced liver CT scan. Methods. 324 patients who underwent plain and dual phase enhanced liver CT were randomly assigned to 2 groups: G1 (n=224, individualized contrast medium injection protocol; G2 (n=100, standard contrast medium injection with a dose of 1.5 ml/kg. CT values and ΔHU (CT values difference between plain and enhanced CT of liver parenchyma and tumor-liver contrast (TLC during hepatic arterial phase (HAP and portal venous phase (PVP and contrast medium dose were measured. The tumor conspicuity of hepatocellular carcinoma (HCC between two groups was independently evaluated by two radiologists. Results. The mean contrast medium dose of G1 was statistically lower than that of G2. There were no significantly statistical differences in CT values and ΔHU of liver parenchyma during HAP, TLC values during HAP, and PVP between two groups. The CT values and ΔHU of liver parenchyma during PVP of G2 were significantly higher than those of G1. Two independent radiologists were both in substantial conformity in grading tumor conspicuity. Conclusion. Using the individually optimized injection protocol might reduce contrast medium dose without impacting on the imaging quality in enhanced liver CT.

  8. The affects of contrast medium on renal function in selective coronary angiography and intervention

    International Nuclear Information System (INIS)

    Chen Yueguang; Lv Baojing

    2006-01-01

    Selective coronary angiography and intervention with injection of contrast medium into the coronary arteries has become very common in dealing with coronary cardiac diseases. The excretion of contrast medium through kidneys may lead to acute renal functional insufficiency, especially for those suffering from chronic nephropathy, diabetes and cardiac functional disorder to form the so called 'contrast medium nephropathy' which is considered as the number second drug induced acute renal functional failure. Although routine preventive measure including low osmotic contrast medium and fine hydrotherapy have been taken, 14% incidences still occur with renal functional damage. The majority could be reversible but the minority needs emergent hemodialysis or even with persistent renal functional damage in a few ones. (authors)

  9. Contrast-medium-induced nephropathy: is there a new consensus? A review of published guidelines

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.; Morcos, Sameh K.

    2006-01-01

    The interest in contrast-medium-induced nephropathy has increased considerably during the last few years. Various guidelines regarding identifying patients at risk and measures to reduce the incidence of this complication have been proposed. The aim of this review was to analyse whether there is some consistency amongst these guidelines. A Medline search for the keyword ''contrast medium induced nephropathy'' during the period from the beginning of 2003 through the end of September 2005 was carried out. Only papers in English were reviewed. Thirteen guidelines were identified. Inconsistency was observed regarding advise on the prophylactic use of drugs and the isoosmolar dimer to reduce the incidence of contrast-medium-induced nephropathy. Consistency was found in relation to the importance of hydration, cessation of intake of nephrotoxic drugs and administration of the lowest possible dose of contrast medium. No new consensus has been observed in comparison to the European Society for Urogenital Radiology (ESUR) guidelines, which were published in 1999. (orig.)

  10. Aspiration of barium contrast medium in an elderly man with disordered swallowing

    OpenAIRE

    Bağcı Ceyhan, B.; Çelikel, T.; Koç, M.; Ahıskalı, R.; Biren, T.; Ataizi Çelikel, Ç.

    1995-01-01

    The aspiration of contrast medium during the investigation of gastrointestinal diseases is a well recognized hazard, particularly in patients with swallowing disorders. A case is reported in which accidental aspiration of contrast barium occurred owing to disordered swallowing in an elderly man. The infiltration on chest x-ray persisted 2 years after barium contrast aspiration. Inflammatory reaction and retractile, granular material observed in lung biopsy specimens suggested barium-induced p...

  11. Recommendation to use iso-osmotic contrast medium in interventional treatment

    International Nuclear Information System (INIS)

    Zhou Bing; Cheng Yongde

    2012-01-01

    With the rapid development of imaging diagnostic and interventional therapeutic techniques, the contrast medium (CM) has been used more and more common in clinical practice, and meanwhile more and more attention has been paid to the CM-related adverse events. Contrast induced nephropathy (CN) is the most common CM-related adverse event, and CM-related neurotoxicity has already attracted the physicians' attention. The osmotic pressure of the iso-osmotic contrast medium (IOCM) is quite the same as that of the plasma, and therefore its safety is higher than that of low-osmotic contrast medium (LOCM), the patient's tolerance to IOCM is better than that to LOCM. For this reason, the use of IOCM should be strongly recommended in interventional procedures, which is of great significance to the reduction of the occurrence of CM-related adverse events. (authors)

  12. CT contrasting theory. Effects of the concentration, volume and infusion rate of iodine contrast medium on TDC

    International Nuclear Information System (INIS)

    Yamachi, Jun

    2007-01-01

    This study was performed to evaluate the effects in the title on TDC (time-density curve) using a phantom. CT machine used was Toshiba Aquilion Multi 64, TDC phantom was the product of Nemoto-Kyorindo Co., and the contrast medium was Eisai iomeprol, in syringe-sealed formulations of 300 and 350 mg I/mL. The medium was infused at 1-5 mL/sec in the phantom equivalent to body weight of 78 kg (total water volume=1 min circulation=6,000 mL, 800 mL/heart) to obtain 30 TDCs. Evaluated were the relationships of the infusion rate (mL/sec), volume (mL) or time (sec) with TDC parameters of the detection time of the medium, slope, time to reach the maximum CT value, the maximum CT value, time to keep the CT concentration and its actual concentration. Results revealed that, regardless to the difference of formulations of the contrast medium, TDC with high reproducibility can be obtainable by making the infusion rate of I per unit time and body weight (mgI/sec/kg) constant when the infusion time is made identical for CT of the same diagnostic purpose. (R.T.)

  13. Evaluation of changes in vertebral body density following administration of contrast medium during routine CT examination

    International Nuclear Information System (INIS)

    Janicek, M.; Bruna, J.; Stenhova, H.

    1984-01-01

    The possibility is discussed of depicting changes in the density of spongiosis of the vertebral body in normal patients after intravenous administration of a bolus of 40 ml 60% Diazetrizoate in the course of a routine CT examination. The average increase in density immediately after the administration of the contrast medium is 12 H (8%), in the course of 10 minutes is reduced to 5 H (4%) against the initial values in native examination. These average changes are statistically significant, in individual patients, however, the increase in density following the administration of a contrast medium fluctuates considerably (from 0.7% to 10%). Only systematic comparison with various pathological conditions will make it possible to assess the possibilities of the evaluation of the structure of the vertebral body in routine CT with the administration of a contrast medium into the blood flow. (author)

  14. Effects of use of the lodine contrast medium on gamma camera imaging

    Energy Technology Data Exchange (ETDEWEB)

    Pyo, Sung Jae; Cho, Yun Ho [Dept. of Nuclear Medicine, Inha University hospital, Incheon (Korea, Republic of); Choi, Jae Ho [Dept. of Radiological Technology, Ansan College, Ansan (Korea, Republic of)

    2016-12-15

    Effects of Gamma camera imaging on gamma ray counting rates as a function of use and density of the iodine contrast medium currently in primary use for clinics, and changes in gamma ray counting rates as a function of the contrast medium status upon attenuation correction using a CT absorption coefficientin an SPECT/CT attenuation correction will be considered herein. For experimental materials used 99mTcO4 370 MBq and Pamiray 370 mg, Iomeron 350 mg, Visipaque 320 mg, Bonorex 300 mg of iodine contrast medium. For image acquisition, planar imaging was consecutively filmed for 1, 2, 3, 4, 5 min, respectively, 30 min after administration of 99mTcO4. while 60 views were filmed per frame for 20 min at 55 min for the SPECT/CT imaging. In planar imaging, the gamma ray counting rates as a function of filming time were reduced showing a statistically significant difference when mixed according to the type of contrast medium density rather than when the radioactive isotope 99mTcO4 and the saline solution were mixed. In the tomography for mixing of the radioactive isotope 99mTcO4 and saline solution, the mean counting rate without correction by the CT absorption coefficient is 182±26 counts, while the counting rate with correction by the CT absorption coefficient is 531.3±34 counts. In the tomography for mixing of the radioactive isotope 99mTcO4 and the saline solution with the contrast medium, the mean values before attenuation correction by CT absorption coefficient were 166±29, 158.3±17, 154±36, and 150±33 counts depending on the densities of the contrast medium, while the mean values after attenuation correction were 515±03, 503±10, 496±31, and 488.7±33 counts, showing significant differences in both cases when comparatively evaluated with the imaging for no mixing of the contrast medium. Iodine contrast medium affects the rate of gamma ray. Therefore, You should always be preceded before another test on the day of diagnosis.

  15. Acute Severe Thrombocytopenia Following Non-Ionic Low-Osmolarity Intravenous Contrast Medium Injection

    Energy Technology Data Exchange (ETDEWEB)

    Bata Pal; Domonkos, Adam; Tamoki, David Laszio; Horvath, Evelin; Berczi, Viktor; Szalay, Ferenc [Semmelweis University, Budapest (Hungary)

    2012-07-15

    Intravenous contrast medium (ICM) rarely induces anaphylactic reactions, including urticaria, hypotension and respiratory failure. Even the most modern ICM may cause such adverse events. Thrombocytopenia has been reported as an extreme rare consequence of ICM. Here we report on a case of a 72-year-old male patient with a self-limiting severe acute thrombocytopenia following administration of intravenous non-ionic low-osmolarity contrast medium. No such low platelet count has ever been reported. We also present a review of the literature.

  16. Use of iohexol as a gastrointestinal contrast medium in the dog

    International Nuclear Information System (INIS)

    Agut, A.; Sanchez-Valverde, M.A.; Lasaosa, J.M.; Murciano, J.; Molina, F.

    1993-01-01

    Iohexol was administered orally in five dogs. The dose, gastrointestinal (GI) transit time, appearance of mucosal patterns and side effects were studied. Three different doses (525, 700, 875 mgI/kg) were used in each dog at 1-week intervals. GI transit time was rapid. In each dose, gastric emptying commenced immediately after administration of the contrast medium, and was completed within 30–60 min with doses of 525–700 mgI/kg and 90–120 min with 875 mgI/kg. Large intestinal filling was observed within 60-90 min. In the majority of studies, the mucosal border appeared as a thin homogeneous halo of lucency surrounding the more opaque bowel lumen contents. The contrast intensity was not adequate with the lowest dose. The image quality did not deteriorate along the GI tract. No adverse reactions were found. Iohexol is an alternative GI contrast medium in the dog when contrast media are contraindicated

  17. MRI of the liver with the new contrast medium Gd-BOPTA

    International Nuclear Information System (INIS)

    Vogl, T.J.; Pegios, W.; Balzer, J.; Lissner, J.; Pirovano, G.

    1992-01-01

    A phase 1 study on 8 normals has been carried out to determine the effectiveness and safety during MRI of a new hepatobiliary contrast medium Gd-BOPTA for causing enhancement of the upper abdominal organs. Gradient echo sequences (flash), T 1 and T 2 -weighted spin echo sequences and turbo-flash sequences were used. The contrast medium was given as a single infusion in various concentrations (0.005, 0.05, 0.1 and 0.2 mmol/kg body weight). Optimal contrast of liver parenchyma was obtained with a dose of 0.05-0.1 mmol/kg body weight, resulting in contrast increase of 149.1% during gradient echo sequences and 107.8% during T 1 spin echo sequences. In general, the increased contrast lasted for about two hours. Because of the biliary and renal excretion there was an enormous increase in signal intensity of the bile ducts and a significant increase in the kidneys and ureters. The results of the first in-vivo-trial of Gd-BOPTA encourages the performance of further clinical studies of this new hepatobiliary contrast medium. (orig.) [de

  18. Contrast-enhanced magnetic resonance imaging for the detection of acute haemorrhagic necrotizing pancreatitis

    International Nuclear Information System (INIS)

    Piironen, A.; Kivisaari, R.; Pitkaeranta, P.; Poutanen, V.P.; Laippala, P.; Laurila, P.; Kivisaari, L.

    1997-01-01

    Eleven piglets with haemorrhagic necrotizing pancreatitis and nine piglets with oedematous pancreatitis were imaged using a multi-breath-hold TurboFLASH (TR 6.5 ms, TE 3 ms, TI 300 ms, flip angle 8 , three slices) pre-excited T1-weighted sequence with an IV bolus injection of gadopentetate dimeglumine (Gd-DTPA, 0.3 mmol/kg) as a contrast agent to show dynamic contrast enhancement of the pancreas by MRI. All piglets were imaged according to the same protocol before inducing the disease. Following the IV Gd-DTPA bolus, time-enhancement curve of the pancreas during haemorrhagic necrotizing pancreatitis was significantly lower than during oedematous pancreatitis. The enhancement curves for the healthy piglets and piglets with oedematous pancreatitis did not differ significantly. Each piglet served as its own control. Because the results of this initial study are similar to those obtained with contrast-enhanced CT, we conclude that our results may encourage further clinical trials, and contrast-enhanced dynamic MRI may be an alternative to the established method of CT for diagnosing acute haemorrhagic necrotizing pancreatitis. (orig.). With 3 figs

  19. Contrast enhancement technique in brain 3D-CTA studies. Optimizing the amount of contrast medium according to scan time based on TDC

    International Nuclear Information System (INIS)

    Terasawa, Kazuaki; Hatcho, Atsushi

    2008-01-01

    In three-dimensional CT angiography (3D-CTA), good reproducibility can be obtained by maintaining the maximum CT numbers (HU) at a specified level. However, the correlation between the scan time and the injection time showed that the maximum CT numbers increased and varied due to the additional contrast enhancement effect from recirculation of the injected contrast medium for longer injection times when the dose of iodinated contrast medium per unit time (mgI/s) was maintained at a specified level based on the time-density curve (TDC) of the phantom. The amount of contrast medium employed at our hospital has been optimized based on an iodinated contrast medium dose per unit time providing a contrast enhancement effect of 300 HU in the middle cerebral artery. Using this standard, a TDC phantom was employed to obtain an iodinated contrast medium dose per unit time, permitting equivalent maximum CT values (used as standard values) to be obtained by changing the injection time. A contrast-enhancement technique that accounts for the variation in the scan time was evaluated. Strong correlations were observed between the scan time and the injection time (R 2 =0.969) and between the injection time and the dose of iodinated contrast medium per unit body weight (R 2 =0.994). We conclude that adjusting the dose of iodinated contrast medium per unit body weight per unit time according to the scan time permits optimization of the contrast-enhancement technique. (author)

  20. Enhanced MRI of breast cancer smaller than 3 cm

    International Nuclear Information System (INIS)

    Ikeda, Yukio; Yoshida, Shouji; Narabayashi, Isamu

    1991-01-01

    Twenty-two patients with breast cancers were studied using magnetic resonance (MR) imaging with a cylindrical surface coil at 1.5 Tesla. All were examined with the FE sequence and Gd-DTPA as a contrast medium. These images were compared with micrographs of the specimens. All cancers were enhanced clearly, and demarcated margins or spiculations of the tumors were seen as clearly on MR images as on micrographs of the specimens. In 12 patients (9 carcinomas, 2 fibroadenomas and 1 benign phyllodes tumor), dynamic studies were performed after the intravenous injection of Gd-DTPA. All nine carcinomas showed enhancement characterized by a sudden increase in signal intensity on the order of 100% or more with the first 2 minutes after injection. Two fibroadenomas were enhanced slowly. Thirteen patients with breast cancers were examined with several sequences (FE, T 1 -weighted SE, T 2 -weighted SE and STIR) with or without Gd-DTPA. The most clearly delineated images of the tumors were those of FE images with Gd-DTPA enhancement. A phantom constituted of various concentrations of Gd-DTPA in 20% albumin solution was measured by signal intensities with T 1 -weighted SE sequence and FE sequence. The ratio of enhancement of the 20% albumin solution relative to the Gd-DTPA concentration was higher with the FE sequence than with the SE sequence. The sensitivity of the FE sequence to Gd-DTPA enhancement was 1.5 times that of the SE sequence under the usual concentration of Gd-DTPA. (author)

  1. CO{sub 2} as a contrast medium in endoluminal treatment of high flow vascular malformations

    Energy Technology Data Exchange (ETDEWEB)

    Gorriz, Elias; Carreira, Jose M.; Reyes, Ricardo; Gallardo, Laura; Pulido, Juan M.; Romero, Alejandro; Maynar, Manuel

    1999-09-01

    Purpose: To evaluate the diagnostic usefulness of CO{sub 2} as a radiologic contrast medium in pre and post-embolization of hemodynamically active vascular malformations. Material and methods: Eight pre and post-embolization angiographies were performed on five patients with hemodynamically active vascular malformations. In all cases sequentially iodinated contrast medium and CO{sub 2} were used. Procedures were performed using Philips Integris V equipped with specific software to process images obtained with CO{sub 2} as contrast medium and with a purpose-built gas injector pump. The images were assessed by three interventional radiologists who evaluated the findings by consensus. They were asked whether uptake of the malformations were better, worse or the same with iodinated contrast and CO{sub 2}. The images were judged according to the following characteristics; quality, the filling in of the contrast in afferent artery of the HAVM, caliber and number of vessels and existence of pathologic communications in HAVM. These characteristics were assessed in all the patients of the study, both before and after embolization. Results: The CO{sub 2} angiographic results were compared to those obtained using iodinated contrast material. Iodinated contrast provided superior image quality in all performed studies. The filling of arterial afference of HAVM was well defined with both contrast media. In all performed cases with CO{sub 2}, the malformations showed more vessels. No immediate nor subsequent complications developed with CO{sub 2} injections, except in one female patient, who presented an intense sensation of cramps in the lower limbs. Conclusion: CO{sub 2} is a useful diagnostic and assessment tool before and especially during the embolization of hemodynamically active vascular malformations. It improves quantification and uptake of the malformation's vascular architecture, detecting collateral circulation and arteriovenous shunts. It also detects residual

  2. Oral contrast medium in PET/CT: should you or shouldn't you?

    International Nuclear Information System (INIS)

    Groves, Ashley M.; Kayani, Irfan; Dickson, John C.; Townsend, Caroline; Croasdale, Ian; Syed, Rizwan; Nagabushan, Nagesh; Hain, Sharon F.; Ell, Peter J.; Bomanji, Jamshed B.

    2005-01-01

    It has been suggested that the use of computed tomography (CT) positive contrast agents has led to attenuation-induced artefacts on 18 F-fluorodeoxyglucose positron emission tomography ( 18 F-FDG PET/CT) systems. Consequently, centres may withhold the use of such agents. Whilst there is theoretical evidence to support the aforementioned claim, the clinical relevance of the induced artefacts has not been widely established. Moreover, the potential benefits of bowel enhancement on PET/CT have yet to be formally evaluated. We therefore prospectively examined PET/CT studies to assess whether the use of oral contrast medium induces clinically relevant artefacts and whether the use of these agents is diagnostically helpful. Over a 2-month period, 18 F-FDG PET/CT images were prospectively reviewed from 200 patients following Gastrografin administration 2 h prior to examination. Both a radiologist and a nuclear medicine physician reviewed the images for contrast medium-mediated clinically relevant artefacts. Artefacts were sought on the CT attenuation-corrected images and were compared with the appearance on non-attenuated-corrected images. The number of examinations in which the oral contrast aided image interpretation was also noted. There were no oral contrast medium-induced clinically significant artefacts. In 38 of the 200 patients, oral contrast aided image interpretation (owing to differentiation of mass/node from bowel, discrimination of intestinal wall from lumen or definition of the anatomy of a relevant site). In 33 of these 38 patients, the anatomical site of interest was the abdomen/pelvis. The use of oral contrast medium in 18 F-FDG PET studies should not be withheld as it improves image interpretation and does not produce clinically significant artefacts. (orig.)

  3. Digital subtraction angiography and intraarterial contrast medium injection for coronary examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tobio, R.; Kallmeyer, C.; Castello, J.

    1985-01-01

    Digital subtraction angiography (DSA) is an established method of vasography, most extensively used as i.v. DSA. Intraarterial injection, however, applying selective or non-selective contrast medium injection, seems to be at least as important a technique although it has not yet met with corresponding interest. The article explains advantages of the technique for angiographic examinations, in particular of coronary angiography.

  4. Comparison between two positive and one negative oral contrast medium for abdominal CT diagnosis

    International Nuclear Information System (INIS)

    Zwaan, M.; Gmelin, E.

    1989-01-01

    In a prospective randomised study three groups of 30 patients each were subjected to CT of the entire abdomen. The oral intestinal contrast media used were iodine solution (2%), barium suspension (1.5%) and paraffin emulsion (25%). The results were evaluated according to imaging, artifacts, assessability of the intestinal wall, taste and side effects. All three contrast media are suitable for marking the gastrointestinal tract; paraffin shows advantages in the upper part of the tract and is the only medium that enables assessment of the wall, while causing the lowest rate of artifacts. Barium has a high acceptance and the best tolerance of all contrast agents. (orig.) [de

  5. Transient partial amnesia complicating cardiac and peripheral arteriography with nonionic contrast medium

    International Nuclear Information System (INIS)

    Yildiz, A.; Yencilek, E.; Apaydin, F.D.; Duce, M.N.; Oezer, C.; Atalay, A.

    2003-01-01

    The aim of this study was to present a case of disruption of the blood-brain barrier during the coronary and lower extremity angiographies with radiological and clinical findings. This condition was secondary to intraarterial use of a nonionic, monomeric contrast medium. A total of 450 cc contrast media was used. Computed tomography examination showed contrast enhancement of the right occipital and frontoparietal cortical regions, which returned to normal one day after. The patient also fully recovered from the neurological symptoms within 24 h. We discussed the possible mechanism for blood-brain barrier disruption in this case. (orig.)

  6. Transient partial amnesia complicating cardiac and peripheral arteriography with nonionic contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Yildiz, A.; Yencilek, E.; Apaydin, F.D.; Duce, M.N.; Oezer, C. [Dept. of Radiology, Mersin Ueniv. Tip Fakueltesi Sokak Mersin (Turkey); Atalay, A. [Dept. of Cardiology, Mersin Ueniv. Tip Fakueltesi Sokak Mersin (Turkey)

    2003-12-01

    The aim of this study was to present a case of disruption of the blood-brain barrier during the coronary and lower extremity angiographies with radiological and clinical findings. This condition was secondary to intraarterial use of a nonionic, monomeric contrast medium. A total of 450 cc contrast media was used. Computed tomography examination showed contrast enhancement of the right occipital and frontoparietal cortical regions, which returned to normal one day after. The patient also fully recovered from the neurological symptoms within 24 h. We discussed the possible mechanism for blood-brain barrier disruption in this case. (orig.)

  7. Clinical experience with a commercially available negative oral contrast medium in PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hausegger, K.; Reinprecht, P. [Roentgendiagnostisches Zentralinstitut, LKH Klagenfurt (Austria); Kau, T. [Roentgendiagnostisches Zentral Inst., Klagenfurt (Austria); Igerc, I.; Lind, P. [Abt. fuer Nuklearmedizin und Spezielle Endokrinologie, LKH Klagenfurt (Austria)

    2005-06-01

    Purpose: to evaluate a commercially available negative oral contrast material for PET/CT. Material and methods: in a prospective series of 49 patients, Mukofalk {sup registered}, which is a vegetarian-based substance, was used as a negative oral contrast medium in whole body PET/CT studies. Mukofalk was administered during a time period of 1.5 hours before the examination. Quality of small bowl distension and eventual pathological tracer uptake in the intestine were evaluated. Results: distension of the small bowel was excellent or good in 41 (85%) and poor in 8 (15%) patients. Mild tracer uptake in the small bowel was observed in 5 patients (10.2%) and moderate uptake in another 2 patients (4%). In none of these patients did the F-18 FDG uptake interfere with image interpretation. Conclusion: Mukofalk {sup registered} can be used as a negative oral contrast medium in PET/CT studies. (orig.)

  8. Intravenous contrast medium application in elderly patients - evaluation of Iopentol (Imagopaque trademark 300)

    International Nuclear Information System (INIS)

    Rathsmann, P.; Jacobs, G.F.; Mueller, R.D.

    2004-01-01

    Purpose: We examined the subjective compatibility of elderly patients who received the intravenous contrast medium Iopentol (Imagopaque trademark 300). In addition, objective data were acquired to show possible interactions between contrast media and organ systems in old patients. Methods and materials: A CT scan with intravenous application of contrast media was performed on 132 patients ranging in age from 75 to 96 years. The patients were questioned about their individual sensations. In addition, blood pressure, creatinine and CT-densitometry were acquired as objective date. Results: The patients' individual sensations and clinical data show a very low rate of complications. Mild allergic reactions were noticed in two patients. No severe anaphylactic reactions were encountered. Statistically significant changes in blood pressure before and after administration of the contrast medium were not observed. The serum creatinine concentration was unchanged after application of contrast media. For CT-densitometry, the patients were divided into two groups, one group with patients 75-84 years and the other group with patients 85-96 years of age. CT-densitometry showed no age-related differences. The protocol of contrast administration resulted in excellent opacification of the examined regions, only the liver did not enhance in some cases before the opacification of the portal vein. Conclusion: It is shown that old age alone is no reason to withhold contrast media containing iodine when performing CT. For the evaluation of the liver, however, the peculiarities of old age have to be taken into account and the interval between injection of the contrast medium and beginning of the spiral-CT has to be extended. (orig.)

  9. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    CERN Document Server

    Pavlicek, M

    2000-01-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time ...

  10. Effect of barium sulfate contrast medium on rheology and sensory texture attributes in a model food.

    Science.gov (United States)

    Ekberg, O; Bulow, M; Ekman, S; Hall, G; Stading, M; Wendin, K

    2009-03-01

    The swallowing process can be visualized using videoradiography, by mixing food with contrast medium, e.g., barium sulfate (BaSO(4)), making it radiopaque. The sensory properties of foods may be affected by adding this medium. To evaluate if and to what extent sensory and rheological characteristics of mango purée were altered by adding barium sulfate to the food. This study evaluated four food samples based on mango purée, with no or added barium sulfate contrast medium (0%, 12.5%, 25.0%, and 37.5%), by a radiographic method, and measured sensory texture properties and rheological characteristics. The sensory evaluation was performed by an external trained panel using quantitative descriptive analysis. The ease of swallowing the foods was also evaluated. The sensory texture properties of mango purée were significantly affected by the added barium in all evaluated attributes, as was the perception of particles. Moreover, ease of swallowing was significantly higher in the sample without added contrast medium. All samples decreased in extensional viscosity with increasing extension rate, i.e., all samples were tension thinning. Shear viscosity was not as dependent on the concentration of BaSO(4) as extensional viscosity. Addition of barium sulfate to a model food of mango purée has a major impact on perceived sensory texture attributes as well as on rheological parameters.

  11. Water as a contrast medium: a re-evaluation using the multidetector-row computed tomography.

    Science.gov (United States)

    Makarawo, Tafadzwa P; Negussie, Edsa; Malde, Sachit; Tilak, Jacqueline; Gayagoy, Jennifer; Watson, Jenna; Francis, Faiz; Lincoln, Denis; Jacobs, Michael J

    2013-07-01

    Water as an intraluminal negative contrast medium produces improved image quality with reduced artefact. However, rapid absorption of oral water in the bowel relative to speed and timing of image capturing has limited its clinical application. These findings predate advances in multidetector-row computed tomography (CT). To re-evaluate differences in image quality, we studied image clarity and luminal distention between the same group of patients who received both a pancreas protocol CT (PPCT) that uses oral water and a conventional positive oral contrast scan. We reviewed 66 patients who had previously undergone both a PPCT and an oral contrast abdominal CT. CT images were independently reviewed by two board-certified radiologists who scored degree of hollow viscus distention and visualization of mural detail using a Likert 5-point scale. Results were evaluated by using the Wilcoxon-signed rank test. Student's t test was applied to evaluate the differences in radiation dosage and Spearman's correlational test was used to evaluate interrater correlation between the radiologists. In comparing the mean radiation dosage, there was no statistical difference between the two protocols, and there was good interrater association with ratios of 0.595 and 0.51 achieved for the PPCT and conventional oral scan, respectively. The Wilcoxon signed-rank test showed statistical differences in the stomach (P contrast medium causing better or equal distention in the bowel and better or equal clarity than routine barium contrast. This calls for a need to reconsider the use of water as a contrast medium in clinical practice.

  12. Computed tomography of the cervical spine with iv injection of contrast medium

    International Nuclear Information System (INIS)

    Magnaldi, S.; Pozzi-Mucelli, R.S.; Cova, M.A.; De Morpurgo, P.

    1989-01-01

    Computed Tomography (CT) without contrast medium is largely applied to the study of intervertebral disk pathology in the lumbar spine, but has not been widely accepted in cervical spine, due to technical and anatomical limitations. For these reasons many neuroradiologists still prefer myelography or myelo-CT. CT may yield better results if combined with iv contrast medium injection, which allows a better visualization of disk herniation. This technique is aimed at enhancing the density of the venous plexus which is located close to the intervertebral disk the vertebral bodies and the neural foramina. A better contrast enhancement is thus obtained between the disk and the spinal cord. The authors' experience is based on 61 patients who underwent contrast enhanced CT; in 22 cases myelography and myelo-CT were also performed. The authors describe their technique and the most frequent CT findings of disk hernation: the typical finding includes a focal hypodensity surrounded by a linear blush, due to a posteriorly dislocated epidural vein. The posterior linear blush alone may be present in few cases. Contrast enhanced CT is very useful in the study of disk pathology of the cervical spine, even when compared with myelography and myelo-CT, due the increase in the density of epidural plexus it allows. However, the technique must be very accurate if the same results as those of myelo-CT are to be obtained

  13. Diagnostic capabilities of the contrast medium verografin in liposomes (animal experiments)

    International Nuclear Information System (INIS)

    Rozenberg, O.A.; Khason, K.P.; Aliyakparov, M.T.; Davidenkova, E.F.; Zherbin, E.A.; Akademiya Meditsinskikh Nauk SSSR, Leningrad. Inst. Ehksperimental'noj Meditsiny)

    1985-01-01

    Some examples for the diagnosis of various diseases of liver and spleen after intravenous (cats, dogs) or intraportal (rodents) injection of lecithin-cholesterol liposomes containing the water soluble contrast medium verografin are described. Tumors of 1 mm were found in the spleen of mice with lymphogranulomatosis, hepatomas of 3-5 mm in rats and lesions of 10 mm in cats with turpentine abscesses. The application of liposomes containing radiographic contrast media offers good possibilities for the diagnosis of liver and spleen. (author)

  14. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is an x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  15. Contrast medium enhancement of soft tissues and brain in CT examinations of dogs

    International Nuclear Information System (INIS)

    Pavlicek, M.

    2000-11-01

    CT is a x-ray based method which shows less contrast for soft tissue as has been known from radiography. Therefore, it is necessary to use intravenously administered iodine contrast media to detect and localize tumors, fistulas or other pathologic lesions. Usually contrast medium is administered manually which yields random patterns of media distribution due to varying application pressure during varying administration time, therefore enhancement of parenchymous organs could not be used to the optimum extent. The use of an automatic injection pump guarantees the necessary constancy during the examination procedure to undoubtedly detect pathologic enhancement of organs in the CT-image as known from human medicine. The standards which are expected of the injection pump and the contrast media are: a good contrast enhancement, a good accumulation in the examined organs, an accumulation, which lasts long enough during the diagnostic phase, and a rapid excretion without side effects. Because of the short scan time of the modern CT-scanner, the best contrast enhancement can be administered by a short bolus injection, which can be applied by the automatic injection pump with a defined flow and a defined quantity of contrast media. This guarantees a good enhancement in the chosen region for the duration of the scan. The main aim of this study is to find a standardized flow and quantity of contrast media for defined regions and organs considering the speed of the scanner. In a subsequent step, the existing scan-protocols are then updated using the newly found information. This study showed, that CT examination of the head and brain in middle-sized dogs can be administered with a flow of 0.5 ml/s and a dose of 2 ml of contrast medium per kg weight. The contrast enhancement of the brain is caused by the enhancement of the vessels, the parenchym is free of contrast media - brain shows a low increase of density. Only if the blood-brain-barrier is destroyed, it is possible that

  16. The influence of collagen network integrity on the accumulation of gadolinium-based MR contrast agents in articular cartilage

    Energy Technology Data Exchange (ETDEWEB)

    Wiener, Edzard; Schmidt, C.; Diederichs, G. [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie; Settles, M. [Klinikum rechts der Isar, Muenchen (Germany). Inst. fuer Roentgendiagnostik; Weirich, G. [Klinikum Rechts der Isar, Muenchen (Germany). Inst. fuer Pathologie und Pathologische Anatomie

    2011-03-15

    Delayed gadolinium-enhanced MR imaging of cartilage is used to quantify the proteoglycan loss in early osteoarthritis. It is assumed that T 1 after Gd-DTPA administration in the near equilibrium state reflects selective proteoglycan loss from cartilage. To investigate the influence of the collagen network integrity on contrast accumulation, the relaxation rates {delta}R1 and {delta}R2 were compared after Gd-DTPA administration in a well established model of osteoarthritis. Collagen or proteoglycan depletion was induced by the proteolytic enzymes papain and collagenase in healthy bovine patellar cartilage. Using a dedicated MRI sequence, T{sub 1} and T{sub 2} maps were simultaneously acquired before and 11 h after Gd-DTPA administration. Depth-dependent profiles of {delta}R1 and {delta}R2 were calculated in healthy, proteoglycan and collagen-depleted articular cartilage and the mean values of different cartilage layers were compared using the Mann-Whitney-U test. In superficial layers (1 mm) there was no significant difference (p > 0.05) in either {delta}R1 or {delta}R2 between proteoglycan-depleted (16.6 {+-} 1.2 s{sup -1}, 15.9 {+-} 1.0 s{sup -1}) and collagen-depleted articular cartilage (15.3 {+-} 0.9 s{sup -1}, 15.5 {+-} 0.9 s{sup -1}). In deep layers (3 mm) both parameters were significantly higher (p = 0.005, 0.03) in proteoglycan-depleted articular cartilage (12.3 {+-} 1.1 s{sup -1}, 9.8 {+-} 0.8 s{sup -1}) than in collagen-depleted articular cartilage (9.1 {+-} 1.1 s{sup -1}, 8.7 {+-} 0.7 s{sup -1}). Both proteoglycan loss and alterations in the collagen network influence the accumulation of Gd-DTPA in articular cartilage with significant differences between superficial and deep cartilage layers. (orig.)

  17. Magnetic Resonance Imaging in degenerative disease of the lumbar spine: Fat Saturation technique and contrast medium.

    Science.gov (United States)

    D'Aprile, Paola; Nasuto, Michelangelo; Tarantino, Alfredo; Cornacchia, Samantha; Guglielmi, Giuseppe; Jinkins, J Randy

    2018-01-19

    To examine both anterior and posterior elements of the lumbar spine in patients with low back pain using MRI T2-weighted sequences with Fat Saturation (FS) and contrast enhanced T1-weighted sequences with FS. Two thousand eight hundred and twenty (2820) patients (1628 male, 1192 female, mean age 54) presenting low back pain underwent MRI standard examination (Sagittal T1w TSE and T2w TSE, axial T1 SE) with the addition of sagittal and axial T2w Fat Sat (FS) sequences. Among all the patients, 987 (35%) have been studied adding Contrast Enhanced (CE) T1w FS sequences after administration of contrast medium. Among 987 patients studied with contrast medium, we found: active-inflammatory intervertebral osteochondrosis in 646 (65%) patients; degenerative-inflammatory changes in facet joints (facet joint effusion, synovitis, synovial cysts) in 462 (47%); spondylolysis in 69 (7%); degenerative-inflammatory changes of the flava, interspinous and supraspinous ligaments in 245 (25%); inflammatory changes of posterior perispinal muscles in 84 (8%) patients. In patients with suspected no-disc-related low back pain, the implementation of T2w FS and CE T1w FS sequences to the standard MR protocol could allow a better identification of degenerative-inflammatory changes more likely associated to the pain.

  18. Right arm injection of contrast medium reduces venous artifacts in head and neck multislice spiral computed tomography angiography.

    Science.gov (United States)

    Fang, H; Song, Y-L; Li, X-S; Bi, Y-M; Wang, P; Fan, H-X; Meng, L M; Hu, H-X

    2015-12-01

    We tested whether injection of contrast medium via right or left arm would affect venous artifacts on head and neck multislice spiral computed tomography (CT) angiography. 326 patients were enrolled. Each patient was injected with 10 ml of contrast medium at 5 ml/sec. Time of peak contrast value plus an additional 1 sec was defined as delay time. Another 40 ml of contrast medium were injected with the same injection speed. The scanning area ranged from the aortic arch to the top of the head. Left and right forearms were used for intravenous injections of contrast medium in, respectively, 151 and 175 patients. Comparative analyses of image quality included determining contrast medium residues remaining in the superior vena cava, brachiocephalic vein, or subclavian vein, and comparisons of quality of three-dimensional CT angiography. In 75% of head and neck angiographies, the delay time of the common carotid artery ranged from 16 to 22 sec. In 60% of the images, the quality was graded as excellent, with the left arm injection resulting in delay time of > 23 sec and the right arm delay time of > 18 sec. The CT imaging quality after contrast injections via left or right arms was statistically significant (p arm injection was better than after left arm injection. Intravenous injection of contrast medium via right arm reduces artifacts from contrast medium residues and improves the image quality of head and neck CT angiography.

  19. Preoperative differential diagnosis of adnexal lesions: Double contrast-MRI

    International Nuclear Information System (INIS)

    Reuter, M.; Steffens, J.C.; Schueppler, U.; Muhle, C.; Brinkmann, G.; Kohl, G.; Weisner, D.; Luettges, J.; Spielmann, R.P.; Heller, M.

    1996-01-01

    46 patients with benign (n=42) and malignant (n=4) cystic adnexal tumours underwent MRI of the pelvis. Transaxial and coronal images were acquired using conventional T 1 - and T 2 -weighted SE-sequences after oral administration of superparamagnetic iron oxide particles (Ferristene). Additional T 1 -weighted SE-images were obtained immediately following gadoliamide (Gd DTPA-BMA) injection. MRI correctly classified the four malignant lesions, whereas nine histologically benign lesions were misdiagnosed as malignant. Intravenous contrast yielded a superior delineation of intratumoural architecture. Due to exclusion of solid structures, MRI with oral and i.v. contrast enables to dismiss suspected malignity in cystic adnexal lesions. Because of the non-specificity of the macroscopic criteria of dignity, the MR diagnosis 'malignity' is of limited value. (orig./MG) [de

  20. In vitro experiments for the development of a high density (HD) barium sulfate contrast medium

    International Nuclear Information System (INIS)

    Klein, J.

    1986-01-01

    In vitro experiments with the high-density (HD) barium meal Falibaryt HD are described. Several charges of BaSO 4 were tested together with certain additives influencing dispersion, stability of the suspension, flowability, surface tension etc. Particle size spectra were measured by the manufacturer, VEB Fahlberg-List. With a simple PVC test plate containing several grooves simulating small details (areae gastricae) the diagnostic capabilities of the HD contrast medium were evaluated in an in vitro test. The developed barium meal Falibaryt HD is in its physical and chemical parameters comparable with Prontobario-HD, one of the best HD barium meals. (author)

  1. Immediate Adverse Reactions to Gadolinium-Based MR Contrast Media: A Retrospective Analysis on 10,608 Examinations.

    Science.gov (United States)

    Granata, Vincenza; Cascella, Marco; Fusco, Roberta; dell'Aprovitola, Nicoletta; Catalano, Orlando; Filice, Salvatore; Schiavone, Vincenzo; Izzo, Francesco; Cuomo, Arturo; Petrillo, Antonella

    2016-01-01

    Background and Purpose. Contrast media (CM) for magnetic resonance imaging (MRI) may determine the development of acute adverse reactions. Objective was to retrospectively assess the frequency and severity of adverse reactions associated with gadolinium-based contrast agents (GBCAs) injection in patients who underwent MRI. Material and Methods. At our center 10608 MRI examinations with CM were performed using five different GBCAs: Gd-BOPTA (MultiHance), Gd-DTPA (Magnevist), Gd-EOBDTPA (Primovist), Gd-DOTA (Dotarem), and Gd-BTDO3A (Gadovist). Results. 32 acute adverse reactions occurred, accounting for 0.3% of all administration. Twelve reactions were associated with Gd-DOTA injection (0.11%), 9 with Gd-BOPTA injection (0.08%), 6 with Gd-BTDO3A (0.056%), 3 with Gd-EOB-DTPA (0.028%), and 2 with Gd-DTPA (0.018%). Twenty-four reactions (75.0%) were mild, four (12.5%) moderate, and four (12.5%) severe. The most severe reactions were seen associated with use of Gd-BOPTA, with 3 severe reactions in 32 total reactions. Conclusion. Acute adverse reactions are generally rare with the overall adverse reaction rate of 0.3%. The most common adverse reactions were not severe, consisting in skin rash and hives.

  2. Immediate Adverse Reactions to Gadolinium-Based MR Contrast Media: A Retrospective Analysis on 10,608 Examinations

    Directory of Open Access Journals (Sweden)

    Vincenza Granata

    2016-01-01

    Full Text Available Background and Purpose. Contrast media (CM for magnetic resonance imaging (MRI may determine the development of acute adverse reactions. Objective was to retrospectively assess the frequency and severity of adverse reactions associated with gadolinium-based contrast agents (GBCAs injection in patients who underwent MRI. Material and Methods. At our center 10608 MRI examinations with CM were performed using five different GBCAs: Gd-BOPTA (MultiHance, Gd-DTPA (Magnevist, Gd-EOBDTPA (Primovist, Gd-DOTA (Dotarem, and Gd-BTDO3A (Gadovist. Results. 32 acute adverse reactions occurred, accounting for 0.3% of all administration. Twelve reactions were associated with Gd-DOTA injection (0.11%, 9 with Gd-BOPTA injection (0.08%, 6 with Gd-BTDO3A (0.056%, 3 with Gd-EOB-DTPA (0.028%, and 2 with Gd-DTPA (0.018%. Twenty-four reactions (75.0% were mild, four (12.5% moderate, and four (12.5% severe. The most severe reactions were seen associated with use of Gd-BOPTA, with 3 severe reactions in 32 total reactions. Conclusion. Acute adverse reactions are generally rare with the overall adverse reaction rate of 0.3%. The most common adverse reactions were not severe, consisting in skin rash and hives.

  3. MR imaging distinction between occlusive and reperfused myocardial infarctions with a myocardial persistent contrast medium

    International Nuclear Information System (INIS)

    Saeed, M.; Wagner, S.; Wendland, M.; Derugin, N.; Pomeroy, O.; Higgins, C.B.

    1988-01-01

    Paramagnetic contrast agents have limitations for myocardial enhancement of the area at risk after acute occlusion and for differentiating occlusive and reperfused infarctions. A new contrast medium was used in an attempt to discriminate occlusive and reperfused infarctions. The pattern of enhancement was compared in occlusive (6-hour occlusion, 13 rats) and reperfused (2-hour occlusion and 4-hour reperfusion, ten rats) infarctions with electrocardiogram-gated MR imaging. MR imaging of infarcted areas was histologically and histochemically documented. Rats received 100-mM Mn-DPDP. The reperfused infarct showed transmural enhancement early after Mn-DPDP administration. However, occlusive infarcts showed no early enhancement. The difference in the pattern was significant. Mn-DPDP has the potential to distinguish between the occlusive and reperfused infarctions

  4. In which patients should serum creatinine be measured before iodinated contrast medium administration?

    International Nuclear Information System (INIS)

    Thomsen, Henrik S.

    2005-01-01

    Routine measurement of serum creatinine before injection of intravascular iodinated contrast material in all patients would be cumbersome and have an associated cost. There is doubt about whether serum creatinine should be measured routinely in all patients or selectively. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines on this important practical issue. A literature search was carried out and summarized in a report. Based on the available information and discussions amongst the members of the Committee, guidelines were produced. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. The practice for identifying patients at risk of contrast medium induced nephropathy varies considerably from one institution to another. Patients at risk constitute only a small percentage of all cases referred for contrast enhanced imaging examination. However, it is important to identify them and take the necessary precautions. Recent serum creatinine level should be available in patients with an increased probability of a raised serum creatinine level (renal disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout, current intake of nephrotoxic drugs). A simple guideline has been produced. (orig.)

  5. A case of pulmonary edema developed after intraarterial injection of iodinated contrast medium

    International Nuclear Information System (INIS)

    Min, Byoung Chol; Chun, Kang Woo; Koh, Jae Hyu; Yoon, Jong Sup

    1982-01-01

    Pulmonary edema is a rare adverse reaction to the iodinated contrast medium. Complaining of huge abdominal mass, a 52 years old female was admitted to the Hangang Sungsim Hospital. On physical examination, the patient appeared to be healthy. She had stable vital signs, i.e. BP: 120/80 mmHg, pulse rate: 80/min.etc. An adult head sized mass was palpated in the left mid and lower abdomen. Otherwise nonspecific. On laboratory studies the positive findings were 8-10 WBC/HPF in urine, 25.6 mg/dl for BUN and PVC in EKG. It was negative for urine protein, serum creatinline and liver function test. We injected 100 ml and 30 ml of Urografin 60 through the abdominal aorta dividing 3 times and major branches of the abdominal aorta, respectively. Immediately after complicating angiography, interstitial pulmonary edema was found, showing blurring of the vascular margins, perivascular haziness and thickening of the interlobular septal lines in the both lower lung fields. The blood pressure was dropped to 80/60 mmHg, but pulse rate was normal. She did not complain of dyspnea, and cyanosis was not developed. The urine volume was normally maintained. She was treated for pulmonary edema, which was completely absorbed after 20 hours. And the blood pressure was also normalized. We have experienced a case of pulmonary edema developed after intraarterial injection of the iodinated contrast medium without underlying cardiac, renal and hepatic problems, and reviewed the literatures on mechanisms of pulmonary edema caused by intravascular injection of the iodinated contrast materials

  6. Magnesium sulfate as an oral contrast medium in magnetic resonance imaging of the small intestine.

    Science.gov (United States)

    Shi, Hao; Liu, Cun; Ding, Hong Yu; Li, Chun Wei

    2012-03-01

    To explore the use of magnesium sulfate (MgSO4) as an oral contrast medium (CM) in MRI of the small intestine. By comparing MgSO4 SNRs at different concentrations, we determined that 2.5% MgSO4 is the ideal concentration for small bowel MRI. Twenty volunteers underwent MRI after drinking 2.5% MgSO4. Thirty-one patients with clinical suspicion of small intestinal pathology underwent both MRI and the air-barium contrast examination. The patient's tolerance, side effects and complications were noted. 2.5% MgSO4 can decrease the absorption of water and fully fill the enteric cavity, thereby increasing the contrast between the intestinal wall and lumen and facilitating radiographic examination of the small bowel. The mean diameter of the small intestine was 19.8±1.21 mm in the 20 volunteers consuming 2.5% MgSO4 and 12.7±0.84 mm in the 20 volunteers given water. There was a significant difference (P0.05) in side effects between MgSO4 and water groups. Small intestinal MRI was successfully performed in all 31 patients, who were also examined by the double contrast barium, which gave almost identical diagnoses to MRI in all cases except for 1 patient with small intestinal hemorrhage. MRI with 2.5% MgSO4 can demonstrate intestinal abnormalities. Therefore, 2.5% MgSO4 solution is an ideal oral CM for small bowel MRI. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers

    Science.gov (United States)

    Restuccia, Nancy; Torrisi, Lorenzo

    2018-01-01

    The synthesis of Au and Ag nanoparticles (NP) though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM) measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials) and in vivo (in mice), were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.

  8. Nanoparticles generated by laser in liquids as contrast medium and radiotherapy intensifiers

    Directory of Open Access Journals (Sweden)

    Restuccia Nancy

    2018-01-01

    Full Text Available The synthesis of Au and Ag nanoparticles (NP though laser ablation in liquids as a function the laser parameters is presented. Spherical NPs with diameter distribution within 1 and 100 nm were prepared by laser ablation in water. The nanoparticles characterization was performed using optical spectroscopy and electronic microscopy (SEM and TEM measurements. Studies of the possible use of metallic nanoparticles as intensifier of diagnostics imaging contrast medium and absorbing dose from ionizing radiations in traditional radiotherapy and protontherapy are presented. Examples of in vitro (in tissue equivalent materials and in vivo (in mice, were conducted thank to simulation programs permitting to evaluate the enhancement of efficiency in imaging and therapy as a function of the NPs concentrations and irradiation conditions.

  9. Effects of barium sulfate as a contrast medium to enterocutaneous fistulas

    International Nuclear Information System (INIS)

    Pelster, F.W.; Reichelt, S.; Arndt, M.; Eising, E.G.

    1989-01-01

    Fistulation following thoracic and epigastric interventions are conservatively treated, as a rule, because of the high rate of complications expected from reoperation. With properly functioning anastomotic transit, insufficiencies usually undergo spontaneous healing, within four to six weeks. Enterocutaneous fistulae developed in 29 of 271 patients with intrathoracic oesophagastric or oesophagojejunal anastomosis. Syringeal ramification into pleural or abdominal cavities were eliminated by means of an absorbable contrast medium, before barium sulphate was orally administered to all patients. Thoracic fistulae were closed after 21.8 days on average, while 20.3 days was the average period required for closure of epigastric fistulae. Barium sulphate was found to stimulate fistular tissue granulation, so that obliteration of the fistular system occurred much sooner, as compared to conservative treatment. The patient's quality of life can thus be improved, and hospitalisation can be shortened. Neither locally delimited nor systemic complications were observed in any of the cases described. (author)

  10. Iomeprol: results of clinical trials in children with a new nonionic contrast medium

    International Nuclear Information System (INIS)

    Gessel, R. van; Moeller, A.; Schmiedel, E.

    1994-01-01

    A total of 438 patients (1 day - 17 years) were enrolled in open-label phase III studies with Iomeprol in the most important radiologic, urologic, and cardiologic indications. Iomeprol was tested in five concentrations ranging from isotonic solutions of 150 mg iodine/ml up to 400 mg iodine/ml. Half of the patients were younger than 3 years. Apart from the mostly slight sensations of heat, pain, and taste, the following adverse events were observed independently of a causal relationship to the test compound: vomiting (1.8%), rise in blood pressure (1.8%), and restlessness (1.1%). The respective incidence of all other adverse events was below 1%. Iomeprol is a suitable and well-tolerated nonionic contrast medium for use in pediatric examinations. (orig./MG) [de

  11. Bilateral Renal Fornix Rupture Following Intraarterial Contrast Medium Application for Infrarenal Aortic Stent Placement

    International Nuclear Information System (INIS)

    Niggemann, Pascal; Brehmer, Bernhard; Schuermann, Karl

    2006-01-01

    A 74-year-old male claudicant who had a significant abdominal aortic stenosis was hydrated before aortic stent placement because of an elevated creatinine level. During the intervention the patient experienced acute abdominal pain with vomiting. No vascular cause was detected. Due to persistant pain, plain radiography and an abdominal CT scan were performed a few hours after the procedure. Images revealed a bilateral renal fornix rupture with a large retroperitoneal fluid collection. The patient was treated conservatively with ureteral double-J placement and percutaneous nephrostomy. The further course was uneventful and the patient was discharged 2 weeks later free of symptoms. Renal fornix rupture is a very rare complication after contrast medium application that can be treated without surgery

  12. On the Use of Molecular Weight Cutoff Cassettes to Measure Dynamic Relaxivity of Novel Gadolinium Contrast Agents: Example Using Hyaluronic Acid Polymer Complexes in Phosphate-Buffered Saline

    International Nuclear Information System (INIS)

    Kasraie, Nima; Oviatt, Henry Wayne; Clarke, Geoffrey David

    2011-01-01

    The aims of this study were to determine whether standard extracellular contrast agents of Gd(III) ions in combination with a polymeric entity susceptible to hydrolytic degradation over a finite period of time, such as Hyaluronic Acid (HA), have sufficient vascular residence time to obtain comparable vascular imaging to current conventional compounds and to obtain sufficient data to show proof of concept that HA with Gd-DTPA ligands could be useful as vascular imaging agents. We assessed the dynamic relaxivity of the HA bound DTPA compounds using a custom-made phantom, as well as relaxation rates at 10.72 MHz with concentrations ranging between 0.09 and 7.96 mM in phosphate-buffered saline. Linear dependences of static longitudinal relaxation rate (R1) on concentration were found for most measured samples, and the HA samples continued to produce high signal strength after 24 hours after injection into a dialysis cassette at 3T, showing superior dynamic relaxivity values compared to conventional contrast media such as Gd-DTPA-BMA

  13. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    Energy Technology Data Exchange (ETDEWEB)

    Oztoprak, I. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey)], E-mail: oztoprak@cumhuriyet.edu.tr; Guemues, C.; Oztoprak, B. [Department of Radiology Cumhuriyet University Faculty of Medicine, 58140 Sivas (Turkey); Engin, A. [Department of Infectious Diseases, Cumhuriyet University Faculty of Medicine, Sivas (Turkey)

    2007-12-15

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas.

  14. Contrast medium-enhanced MRI findings and changes over time in stage I tuberculous meningitis

    International Nuclear Information System (INIS)

    Oztoprak, I.; Guemues, C.; Oztoprak, B.; Engin, A.

    2007-01-01

    Aim: To demonstrate the detailed imaging characteristics of early tuberculous meningitis (TBM) and changes over time on standard gadolinium-enhanced, T1-weighted magnetic resonance imaging (MRI) images. Materials and methods: Contrast-enhanced, T1-weighted, spin-echo MRI images of 26 patients with early TBM were evaluated retrospectively. Meningeal enhancement characteristics were categorized according to distribution and pattern as diffuse, focal, linear, nodular, and mixed. Results: We found that 35% of patients had diffuse meningeal enhancement and 65% of cases had focal meningeal enhancement. There was a predilection for focal meningeal enhancement in basal pial areas, the interpeduncular fossa being the most common. In six patients with diffuse meningeal enhancement admitted to hospital relatively early after the onset of symptoms, the type of meningeal enhancement later changed to the focal form. Conclusion: Reactive diffuse meningeal enhancement occurs in the early period of TBM on contrast medium-enhanced T1-weighted MR images, but later becomes limited to basal areas

  15. Arterial and venous blood pressure and blood flow following femoral angiography with a new non-ionic contrast medium

    International Nuclear Information System (INIS)

    Nyman, U.; Almen, T.

    1978-01-01

    At femoral angiography in dogs the effects of a new non-ionic contrast medium (C29) were compared with those of one non-ionic medium (metrizamide) and one ionic medium (meglumine/sodium diatrizoate) in current use. In the leg subjected to angiography the pressure gradient over the peripheral vessels decreased and the femoral blood flow increased. The changes induced by the ionic medium were significantly greater than those induced by metrizamide and C29, whereas no significant difference between the two non-ionic media was recorded. (Auth.)

  16. Analysis on the entrance surface dose and contrast medium dose at computed tomography and angiography in cardiovascular examination

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Hyun [Dept. of Cardiovascular Center, Yeocheon Jeonnam Hospital, Yeosu (Korea, Republic of); Han, Jae Bok; Choi, Nam Gil; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-12-15

    This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48-85 years old (mean 65±10 years old), and the weight was 37.6~83.3 kg (mean 63±6 kg). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

  17. In vitro evaluation of alternative oral contrast agents for MRI of the gastrointestinal tract

    International Nuclear Information System (INIS)

    Babos, Magor; Schwarcz, Attila; Randhawa, Manjit Singh; Marton, Balazs; Kardos, Lilla; Palko, Andras

    2008-01-01

    Purpose: In vitro evaluation of different materials as potential alternative oral contrast agents for small bowel MRI. Materials and methods: The T1 and T2 relaxation times of rose hip syrup, black currant extract, cocoa, iron-deferoxamine solution and a commonly used oral contrast material (1 mM Gd-DTPA) were determined in vitro at different concentrations on a 1.0 T clinical MR scanner. T1 values were obtained with an inversion prepared spoiled gradient echo sequence. T2 values were obtained using multiple echo sequences. Finally the materials were visualized on T1-, T2- and T2*-weighted MR images. Results: The relaxation times of the undiluted rose hip syrup (T1 = 110 ± 5 ms, T2 = 86 ± 3 ms), black currant extract (T1 = 55 ± 3 ms, T2 = 39 ± 2 ms) and 5 mM iron-deferoxamine solution (T1 = 104 ± 4 ms, T2 = 87 ± 2 ms) were much shorter than for a 1 mM Gd-DTPA solution (T1 = 180 ± 8 ms, T2 = 168 ± 5 ms). Dilution of black currant extract to 30% or a 3 mM iron-deferoxamine solution conducted to T1 relaxation times which are quite comparable to a 1 mM Gd-DTPA solution. Despite its much lower metal content an aqueous cocoa suspension (100 g/L) produced T2 relaxation times (T1 = 360 ± 21 ms, T2 = 81 ± 3 ms) more or less in the same range like the 5 mM iron-deferoxamine solution. Imaging of our in vitro model using clinical sequences allowed to anticipate the T1-, T2- and T2*-depiction of all used substances. Cocoa differed from all other materials with its low to moderate signal intensity on T1- and T2-weighted sequences. While all substances presented a linear 1/T1 and 1/T2 relationship towards concentration, rose hip syrup broke ranks with a disproportionately high increase of relaxation at higher concentrations. Conclusions: Rose hip syrup, black currant extract and iron-deferoxamine solution due to their positive T1 enhancement characteristics and drinkability appear to be valuable oral contrast agents for T1-weighted small bowel MRI. Cocoa with its

  18. Usefulness of 3D-VIBE method in breast dynamic MRI. Imaging parameters and contrasting effects

    International Nuclear Information System (INIS)

    Uchikoshi, Masato; Ueda, Takashi; Nishiki, Shigeo; Satou, Kouichi; Wada, Akihiko; Imaoka, Izumi; Matsuo, Michimasa

    2003-01-01

    MR imaging (MRI) has been reported to be a useful modality to characterize breast tumors and to evaluate disease extent. Contrast-enhanced dynamic MRI, in particular, allows breast lesions to be characterized with high sensitivity and specificity. Our study was designed to develop three-dimensional volumetric interpolated breath-hold examination (3D-VIBE) techniques for the evaluation of breast tumors. First, agarose/Gd-DTPA phantoms with various concentrations of Gd-DTPA were imaged using 3D-VIBE and turbo spin echo (TSE). Second, one of the phantoms was imaged with 3D-VIBE using different flip angles. Finally, water excitation (WE) and a chemical shift-selective (CHESS) pulse were applied to the images. Each image was analyzed for signal intensity, signal-to-noise ratio (1.25*Ms/Mb) (SNR), and contrast ratio [(Ms1-Ms2)/{(Ms1+Ms2)/2}]. The results showed that 3D-VIBE provided better contrast ratios with a linear fit than TSE, although 3D-VIBE showed a lower SNR. To reach the best contrast ratio, the optimized flip angle was found to be 30 deg for contrast-enhanced dynamic study. Both WE and CHESS pulses were reliable for obtaining fat- suppressed images. In conclusion, the 3D-VIBE technique can image the entire breast area with high resolution and provide better contrast than TSE. Our phantom study suggests that optimized 3D-VIBE may be useful for the assessment of breast tumors. (author)

  19. DCE-MRI using small-molecular and albumin-binding contrast agents in experimental carcinomas with different stromal content

    Energy Technology Data Exchange (ETDEWEB)

    Farace, Paolo; Merigo, Flavia; Fiorini, Silvia; Nicolato, Elena; Tambalo, Stefano; Daducci, Alessandro [Department of Morphological-Biomedical Sciences, Section of Anatomy and Histology, University of Verona, Verona (Italy); Degrassi, Anna [Nerviano Medical Sciences Institute, Milan (Italy); Sbarbati, Andrea [Department of Morphological-Biomedical Sciences, Section of Anatomy and Histology, University of Verona, Verona (Italy); Rubello, Domenico, E-mail: domenico.rubello@libero.it [Department of Radiology, Nuclear Medicine, Medical Physics, Services of Radiology and Nuclear Medicine, ' S. Maria della Misericordia' Hospital, Viale Tre Martiri 140, 45100 Rovigo (Italy); Marzola, Pasquina [Department of Morphological-Biomedical Sciences, Section of Anatomy and Histology, University of Verona, Verona (Italy)

    2011-04-15

    Objectives: To compare DCE-MRI experiments performed using a standard small-molecular (Gd-DTPA) and an albumin-binding (MS-325) contrast agent in two carcinoma models with different stromal content. Materials and methods: DU-145 or BXPC-3 cancer cells were subcutaneously injected into nude mice. DCE-MRI was performed by a bolus injection of Gd-DTPA or MS-325 about 2 weeks after inoculation. For quantitative analysis a volume of interest was manually drawn over each tumor. To address the heterogeneous enhancement, each tumor volume was then divided into the 20% most-enhancing and the remaining 80% least-enhancing fractions. Mean tumor enhancement was calculated over these selected tumor volumes and compared between tumor groups and contrast agents. Maps of differential enhancement, peak enhancement and time-to-peak were used for visual evaluation. CD31 and VEGF immunohistochemistry were performed in excised tumors. Results: In the 80% least-enhancing volume, at late time points of the dynamic scan, the mean enhancement elicited by MS-325 was higher in BXPC-3 than in DU-145 tumors. In the 20% most-enhancing volume, using either contrast agents, significant difference between the two tumors types were observed only early, while at later time points of the dynamic scan the difference were obscured by the faster washout observed in the BXPC-3 tumors. Enhancement maps confirmed that BXPC-3 tumors were characterized by marked washout rate using either contrast agent, particularly in the higher enhancing peripheral rim. With MS-325 this washout pattern appeared to be specific to the BXPC-3 carcinomas, since it was not observed in the DU-145 tumors. Finally, in both tumor types, MS-325 produced significantly higher enhancement than Gd-DTPA in the late phase of the dynamic scan. Ex vivo analysis confirmed the marked presence of aberrant infiltrative stroma in BXPC-3 tumors, in which tumor vessels were embedded. In all tumors the central portion was less viable and less

  20. Intravenous Contrast Medium Administration for Computed Tomography Scan in Emergency: A Possible Cause of Contrast-Induced Nephropathy

    International Nuclear Information System (INIS)

    Sonhaye, Lantam; Kolou, Bérésa; Tchaou, Mazamaesso; Amadou, Abdoulatif; Assih, Kouméabalo; N'Timon, Bidamin; Adambounou, Kokou; Agoda-Koussema, Lama; Adjenou, Komlavi; N'Dakena, Koffi

    2015-01-01

    The goal of this study was to assess risk for CIN after CT Scan during an emergency and to identify risk factors for the patient. Prospective review of all patients admitted to the emergency room (ER) of the Teaching Hospital of Lomé (Togo) during a 2-year period. CIN was defined as an increase in serum creatinine by 0.5 mg/dL from admission after undergoing CT Scan with intravenous contrast. A total of 620 patients underwent a CT Scan in the emergency room using intravenous contrast and 672 patients took the CT Scan without intravenous contrast. Out of the patients who received intravenous contrast for CT Scan, three percent of them developed CIN during their admission. Moreover, upon discharge no patient had continued renal impairment. No patient required dialysis during their admission. The multivariate analysis of all patients who had serial creatinine levels (including those who did not receive any contrast load) shows no increased risk for acute kidney injury associated intravenous contrast (odds ratio = 0.619, p value = 0.886); only diabetes remains independent risk factor of acute kidney injury (odds ratio = 6.26, p value = 0.031)

  1. High-pitch dual-source CT coronary angiography with low volumes of contrast medium

    International Nuclear Information System (INIS)

    Lembcke, Alexander; Hein, Patrick A.; Knobloch, Gesine; Durmus, Tahir; Hamm, Bernd; Schwenke, Carsten; Huppertz, Alexander

    2014-01-01

    To assess the effect of lower volumes of contrast medium (CM) on image quality in high-pitch dual-source computed tomography coronary angiography (CTCA). One-hundred consecutive patients (body weight 65-85 kg, stable heart rate ≤65 bpm, cardiac index ≥2.5 L/min/m 2 ) referred for CTCA were prospectively enrolled. Patients were randomly assigned to one of five groups of different CM volumes (G 30 , 30 mL; G 40 , 40 mL; G 50 , 50 mL; G 60 , 60 mL; G 70 , 70 mL; flow rate 5 mL/s each, iodine content 370 mg/mL). Attenuation within the proximal and distal coronary artery segments was analysed. Mean attenuation for men and women ranged from 345.0 and 399.1 HU in G 30 to 478.2 and 571.8 HU in G 70 . Mean attenuation values were higher in groups with higher CM volumes (P 30 , G 40 , G 50 , G 60 and G 70 were 89 %, 95 %, 98 %, 98 % and 99 %. CM volume of 30 mL in women and 40 mL in men proved to be sufficient to guarantee attenuation of at least 300 HU. In selected patients high-pitch dual-source CTCA can be performed with CM volumes of 40 mL in men or 30 mL in women. (orig.)

  2. Computed tomography of kidney with diuretics. A method for avoiding artifact due to nonionic contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hiromura, Tadao; Terae, Satoshi; Takamura, Akio; Mizoe, Junetsu (Obihiro Kosei Hospital, Hokkaido (Japan)); Morita, Yutaka; Irie, Goro

    1989-07-01

    We devised a method for avoiding beam-hardening artifacts, which interfere with enhanced CT images of kidney due to nonionic contrast medium. The radiographic effect and the frequency of beam-hardening artifacts on enhanced CT of kidney were studied by prospective comparison among three groups: a group of 20 patients examined with furosemide (f-d.CT), a group of 20 patients examined without diuretics (non-d.CT) and a group of 20 patients examined after water intake (w-d.CT). In all patients of f-d.CT group, the renal parenchyma from the cortex to the papilla was almost evently enhanced, free from artifacts. The density of the renal papilla and pelvis in non-d.CT and w-d.CT groups was significantly higher than that in f-d.CT group, and artifacts were also observed in 14 (70%) of non-d.CT group and 12 (60%) of w.d.CT group, respectively. Satisfactory CT of kidney free from artifacts was obtained by f-d.CT, providing easy evaluation of renal pelvic or peripelvic lesions. In conclusion, this technique can be used in those pathologic cases of renal pelvis or peripelvic region, that are not clear on routine CT because of artifacts. (author).

  3. Hydration for the prevention of contrast medium-induced nephropathy. An update

    International Nuclear Information System (INIS)

    Heinrich, M.; Uder, M.

    2006-01-01

    Contrast medium-induced nephropathy (CIN) continues to be one of the most common causes of hospital-acquired acute renal failure. Since most of the clinical studies on the prophylactic use of different drugs to prevent CIN produced disappointing results, hydration remains the mainstay of prophylaxis. A number of recent prospective randomized trials provided further evidence of the effectiveness of hydration and relevant information regarding the optimization of hydration protocols. It was shown that a bolus hydration solely during examination is not sufficient to prevent CIN. In addition, isotonic 0.9% saline was superior to the commonly used halfisotonic 0.45% saline in another trial. An outpatient hydration protocol including oral hydration before the examination followed by forced intravenous hydration over 6 hrs. beginning 30 to 60 min. prior to examination seems to be comparable to the usual hydration over 24 hrs. Another hydration protocol, which could also be very attractive especially for outpatients, included the infusion of sodium bicarbonate. In a recent trial, hydration with sodium bicarbonate, given as a bolus for 1 hr. prior to examination followed by an infusion for 6 hrs. after examination, was more effective than hydration with sodium chloride for the prophylaxis of CIN. However, there is still a lack of large-scale, multi-center trials comparing different hydration protocols and investigating their influence on clinically relevant endpoints such as mortality or the need for dialysis. (orig.)

  4. Feasibility study of using air as a contrast medium in MR colonography

    International Nuclear Information System (INIS)

    So, N.M.C.; Lam, W.W.M.; Mann, D.; Leung, K.L.; Metreweli, C.

    2003-01-01

    AIM: To evaluate the feasibility of using air as intraluminal contrast medium in magnetic resonance (MR) colonography. MATERIALS AND METHODS: Twenty-two patients underwent MR colonography (MRC) using air before colonoscopy. All patients were imaged in prone and supine positions. Each colon was divided into five segments. Two radiologists reviewed the images for the degree of colonic distension, image quality and colonic lesions. The colonic lesions identified using MR were compared with those identified on colonoscopy. RESULTS: Eight men and 14 women with mean age of 55.5 years were studied. All patients completed the MR examination. One hundred and five out of 110 (95.5%) colonic segments were well distended in both prone and supine positions. Image quality was good in all cases. Colonoscopy detected 16 lesions: three ≥1 cm, one 7 mm lesion and 12 lesions ≤5 mm. All lesions 1 cm or larger were detected by MRC. CONCLUSION: MRC using air and the single-shot half-Fourier rapid acquisition with refocused echos (RARE) technique is feasible. But in this small pilot study, it had low sensitivity for the detection of polyps less than 1 cm in diameter

  5. Duplex-assisted carotid artery stenting without administration of contrast medium for patients with chronic kidney disease or allergic reaction.

    Science.gov (United States)

    Mizowaki, Takashi; Fujita, Atsushi; Imahori, Taichiro; Uyama, Atsushi; Inoue, Satoshi; Kohta, Masaaki; Hamaguchi, Hirotoshi; Sasayama, Takashi; Hosoda, Kohkichi; Kohmura, Eiji

    2016-07-01

    We aimed to investigate the safety and feasibility of duplex-assisted carotid artery stenting (CAS) without administration of contrast medium for the prevention of adverse reactions. Fifteen patients (9 % of all CASs) with severe carotid stenosis (≥70 %) associated with chronic kidney disease (CKD) (stage ≥3) or allergy to contrast medium underwent duplex-assisted CAS without administration of contrast medium over 4 years. The procedural success rate and perioperative complication rates were compared between the duplex-assisted CAS (n = 15) and conventional CAS (n = 153) groups. The technical success rate was 100 % in both groups. Combined stroke or death rates during the post-procedural period did not differ significantly between the duplex-assisted CAS group (0/15, 0 %) and conventional CAS group (4/153, 2.6 %). None of the 14 patients with CKD in the duplex-assisted CAS group experienced further deterioration of renal function. The mean surface radiation dose of participants in the duplex-assisted CAS group (n = 13, 312 ± 131 mGy) was significantly lower than that of the conventional CAS group (n = 31, 1036 ± 571 mGy) (p < 0.001). The mean duration of CAS procedure was not significantly different between the duplex-assisted CAS group (156 ± 39.7 min) and the conventional CAS group (156 ± 37.4 min). Duplex-assisted CAS without administration of contrast medium could be an alternative option in selected patients deemed to be at high risk for renal failure from nephrotoxic contrast medium or who have an allergy to contrast medium.

  6. Enhancement effects of test injection with a small amount of MR contrast medium in the oral and maxillofacial region

    International Nuclear Information System (INIS)

    Yanagi, Yoshinobu; Asaumi, Jun-ichi; Konouchi, Hironobu; Hisatomi, Miki; Matsuzaki, Hidenobu; Murakami, Jun; Maki, Yuu; Unetsubo, Teruhisa; Kishi, Kanji

    2006-01-01

    Purpose: To examine whether the signal intensity of dynamic contrast-enhanced MRI (DCE-MRI) is altered by test injection of 1 ml of contrast medium, and if so, whether this change affects the DCE-MRI analysis. Materials and methods: Six healthy volunteers were examined by DCE-MRI using a Magnevist syringe and/or an Omniscan syringe for the injection of contrast medium. Each scan was performed 10 times using steady-state free precession (3D-FISP), a sequence for DCE-MRI, before and after intravenous injection of 1 ml of the contrast medium. The internal pterygoid muscle, masseter muscle, tongue, parotid gland, submandibular gland, bone marrow of the mandible, subcutaneous adipose tissue, and common carotid artery were determined to be regions of interest (ROI), and the ROI internal average signal intensity was measured. The 10 data sets obtained before or after contrast medium administration for each ROI were evaluated using the paired t-test. Results: The test injection increased the signal intensities of six of eight ROIs, with all 20 experiments in the submandibular gland showing significant differences. There was no significant difference in the two ROIs corresponding to the carotid artery and subcutaneous adipose tissue of the cheek. Conclusions: The enhanced signal intensity in the tissue might have been caused by the small amount of contrast medium in the test injection. To eliminate this discrepancy caused by the test injection, a pre-contrast scan should be performed when the average signal intensity of an ROI is measured. We therefore believe that the data obtained before a test injection may be important in the analysis of DCE-MRI

  7. Medium term water deficit elicits distinct transcriptome responses in Eucalyptus species of contrasting environmental origin.

    Science.gov (United States)

    Spokevicius, Antanas V; Tibbits, Josquin; Rigault, Philippe; Nolin, Marc-Alexandre; Müller, Caroline; Merchant, Andrew

    2017-04-07

    Climatic and edaphic conditions over geological timescales have generated enormous diversity of adaptive traits and high speciation within the genus Eucalyptus (L. Hér.). Eucalypt species occur from high rainfall to semi-arid zones and from the tropics to latitudes as high as 43°S. Despite several morphological and metabolomic characterizations, little is known regarding gene expression differences that underpin differences in tolerance to environmental change. Using species of contrasting taxonomy, morphology and physiology (E. globulus and E. cladocalyx), this study combines physiological characterizations with 'second-generation' sequencing to identify key genes involved in eucalypt responses to medium-term water limitation. One hundred twenty Million high-quality HiSeq reads were created from 14 tissue samples in plants that had been successfully subjected to a water deficit treatment or a well-watered control. Alignment to the E. grandis genome saw 23,623 genes of which 468 exhibited differential expression (FDR species-specific response of which 74 were linked to the 'dry' species E. cladocalyx where 23 of these genes were uncharacterised. The majority (approximately 80%) of these differentially expressed genes, were expressed in stem tissue. Key genes that differentiated species responses were linked to photoprotection/redox balance, phytohormone/signalling, primary photosynthesis/cellular metabolism and secondary metabolism based on plant metabolic pathway network analysis. These results highlight a more definitive response to water deficit by a 'dry' climate eucalypt, particularly in stem tissue, identifying key pathways and associated genes that are responsible for the differences between 'wet' and 'dry' climate eucalypts. This knowledge provides the opportunity to further investigate and understand the mechanisms and genetic variation linked to this important environmental response that will assist with genomic efforts in managing native populations

  8. Gd-DTPA-enhanced MR imaging in meningitis

    International Nuclear Information System (INIS)

    Han, M.H.; Chang, K.H.; Roh, J.K.; Kim, I.O.; Han, M.C.; Kim, C.W.

    1988-01-01

    Gd-DPTA-enhanced MR imaging was performed in 16 patients with meningitis (seven tuberculous, four bacterial, three fungal, and two viral) on a 2.0-T unit. Hemorrhagic infarcts of basal ganglia and localized enhancement of thickened dura adjacent were demonstrated on T1-weighted images in three patients with tuberculous meningitis and four with bacterial meningitis, respectively, that were not seen on CT. Enhanced T1-weighted images readily differentiated leptomeningeal enhancement from vessels in two cases with CT of equivocal meningeal enhancement. Nonenhanced T2-weighted images were most sensitive for demonstrating ischemia/infarct and edema. Otherwise, MR images generally matched CT scans

  9. The incidence of contrast medium-induced nephropathy following endovascular aortic aneurysm repair: assessment of risk factors.

    Science.gov (United States)

    Guneyli, Serkan; Bozkaya, Halil; Cinar, Celal; Korkmaz, Mehmet; Duman, Soner; Acar, Turker; Akin, Yigit; Parildar, Mustafa; Oran, Ismail

    2015-05-01

    The aim of the study was to investigate the incidence of contrast medium-induced nephropathy (CIN) and risk factors for CIN following endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair. After exclusion criteria, 139 (121 males, 18 females) patients aged 20-86 (median 65.5) years who underwent endovascular aortic aneurysm repair between January 2002 and September 2013 were included in this retrospective study. CIN, with ≥25% increase in serum creatinine levels within 3 days after contrast medium administration, was compared to the patients' demographics, risk factors, type and complexity of the endovascular operation, parameters regarding to the contrast medium, preoperative estimated glomerular filtration rate (eGFR), and preoperative and early postoperative serum parameters. Statistical analyses were performed with Kolmogorov-Smirnov, χ (2) and Student's t tests. CIN, detected in 39 of 139 patients (28%), was correlated with preoperative eGFR <60 ml/min/1.73 m(2) (P = 0.04) and high preoperative and postoperative serum urea and creatinine levels. Postoperative serum urea levels (P < 0.001) were significant in multivariate analysis. In patients undergoing endovascular aortic aneurysm repair, CIN was correlated with preoperative and postoperative renal impairment, while it was not correlated with the contrast medium dose.

  10. Study of the safety of a new non-ionic contrast medium, iopromide 370 in patients with chronic renal failure

    International Nuclear Information System (INIS)

    Meyrier, A.; Fernet, M.; Rainfray, M.

    1989-01-01

    Intravenous injection of iodinated contrast media usually induces modifications of renal function. Adverse effects of contrast media on renal function may affect diuresis, blood flow or glomerular filtration rate. These modifications are mainly related to osmolality but also chemotoxicity. This open study showed that after i.v. injection of a bolus of iopromide 370, a new non-ionic contrast medium, there was no untoward effect on renal function in patients with renal insufficiency. This justifies comparative studies in patients with renal impairment including elderly subjects, to confirm the tolerance of this product in high risk groups [fr

  11. T1 relaxivities of gadolinium-based magnetic resonance contrast agents in human whole blood at 1.5, 3, and 7 T.

    Science.gov (United States)

    Shen, Yaqi; Goerner, Frank L; Snyder, Christopher; Morelli, John N; Hao, Dapeng; Hu, Daoyu; Li, Xiaoming; Runge, Val M

    2015-05-01

    Calculation of accurate T1 relaxivity (r1) values for gadolinium-based magnetic resonance contrast agents (GBCAs) is a complex process. As such, often referenced r1 values for the GBCAs at 1.5 T, 3 T, and 7 T are based on measurements obtained in media that are not clinically relevant, derived from only a small number of concentrations, or available for only a limited number of GBCAs. This study derives the r1 values of the 8 commercially available GBCAs in human whole blood at 1.5 T, 3 T, and 7 T. Eight GBCAs were serially diluted in human whole blood, at 7 concentrations from 0.0625 to 4 mM. A custom-built phantom held the dilutions in air-tight cylindrical tubes maintained at 37 ± 0.5°C by a heat-circulating system. Images were acquired using inversion recovery sequences with inversion times from 30 milliseconds to 10 seconds at 1.5 T and 3 T as well as 60 milliseconds to 5 seconds at 7 T. A custom MATLAB program was used to automate signal intensity measurements from the images acquired of the phantom. SigmaPlot was used to calculate T1 relaxation times and, finally, r1. Measured r1 values in units of s⁻¹·mM⁻¹ at 1.5 T (3 T/7 T) were 3.9 ± 0.2 (3.4 ± 0.4/2.8 ± 0.4) for Gd-DOTA, 4.6 ± 0.2 (4.5 ± 0.3/4.2 ± 0.3) for Gd-DO3A-butrol, 4.3 ± 0.4 (3.8 ± 0.2/3.1 ± 0.4) for Gd-DTPA, 6.2 ± 0.5 (5.4 ± 0.3/4.7 ± 0.1) for Gd-BOPTA, 4.5 ± 0.1 (3.9 ± 0.2/3.7 ± 0.2) for Gd-DTPA-BMA, 4.4 ± 0.2 (4.2 ± 0.2/4.3 ± 0.2) for Gd-DTPA-BMEA, 7.2 ± 0.2 (5.5 ± 0.3/4.9 ± 0.1) for Gd-EOB-DTPA, and 4.4 ± 0.6 (3.5 ± 0.6/3.4 ± 0.1) for Gd-HP-DO3A. The agents can be stratified by relaxivity, with a significant additional dependency on field strength. This report quantifies, for the first time, T1 relaxivity for all 8 gadolinium chelates in common clinical use worldwide, at current relevant field strengths, in human whole blood at physiological temperature (37°C). The measured r1 values differ to a small degree from previously published values, where such

  12. Magnetic resonance tomography for focal lesions in the liver using the para-magnetic contrast medium gadolinium DTPA

    International Nuclear Information System (INIS)

    Hamm, B.; Roemer, T.; Felix, R.; Wolf, K.J.; Klinikum Charlottenburg, Berlin

    1986-01-01

    The use of the para-magnetic contrast medium gadolinium DTPA for magnetic resonance tomography of focal lesions in the liver was investigated in 31 patients. Two dosage schedules of the contrast medium (0.1 and 0.2 mmol/kg body weight) were used with field strengths of 0.35 and 0.5 Tesla. Using T 1 sequences, gadolinium DTPA showed increased signal intensity in the liver and in tumours, but this was significantly more marked in the tumour. On T 1 spin-echo sequences, previously iso-intense lesions became visible after administration of contrast. On the other hand, contrast-enhanced lesions were less well seen on inversion recovery sequences because of a reduction in the contrast between tumour and liver tissue. The contrast between tumour and liver tissue was not improved by gadolinium DTPA in comparison with precontrast inversion recovery sequences and T 2 spin-echo sequences. The perfusion of intra-hepatic tumours could be elucidated by magnetic resonance tomography after the administration of gadolinium DTPA. (orig.) [de

  13. Theranostic liposomes as a bimodal carrier for magnetic resonance imaging contrast agent and photosensitizer.

    Science.gov (United States)

    Skupin-Mrugalska, Paulina; Sobotta, Lukasz; Warowicka, Alicja; Wereszczynska, Beata; Zalewski, Tomasz; Gierlich, Piotr; Jarek, Marcin; Nowaczyk, Grzegorz; Kempka, Marek; Gapinski, Jacek; Jurga, Stefan; Mielcarek, Jadwiga

    2018-03-01

    The present study is focused on the development of liposomes bearing gadolinium chelate (GdLip) providing two functionalities for magnetic resonance imaging (MRI) and photodynamic therapy of cancer. A lipid derivative of gadolinium(III) diethylenetriamine pentaacetic acid salt (GdDTPA1) was inserted in the liposomal membrane and served as MRI contrast agent whereas a zinc phthalocyanine (ZnPc) was used as a model photosensitizer. In addition to conventional liposomes, pegylated lipids were used for the preparation of "stealth" liposomes. The characterization of different GdLip formulations involved evaluation of the liposomes size by nanoparticle tracking analysis, thermal phase behavior by differential scanning calorimetry and ZnPc-mediated singlet oxygen production. Furthermore, relaxivity measurements were performed as well as cytotoxicity and photodynamic activity against cancerous and normal cell lines was studied. Size and thermal behavior were only slightly influenced by GdLip composition, however it distinctly affected singlet oxygen production of ZnPc-loaded GdLip. The quantum yields of singlet oxygen generation by zinc phthalocyanine incorporated in GdLip containing cationic or/and pegylated lipids were smaller than those obtained for non-pegylated carriers with l-α-phosphatidylglycerol. In general, all formulations of GdLip, irrespectively of composition, were characterized by relaxivities higher than those of commercially used contrast agents (e.g. Magnevist®). NMR study has shown that the incorporation of ZnPc into the formulations of GdLip increases the relaxation parameters r 1 and r 2 , compared to the values for the non-loaded vesicles. GdDTPA1 did not influence the photodynamic activity of ZnPc against HeLa cells. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Effects of high iodine doses given parenterally as contrast medium on parameter of the pro/antioxidative balance

    International Nuclear Information System (INIS)

    Winkler, R.; Griebenow, S.; Scheidleder, B.; Bailer, H.

    2002-01-01

    The aim of this study was to investigate effects of high iodine doses given parenterally as contrast medium on parameters of lipid status and thyroid hormone status as well as on parameters of the pro/antioxidative balance of spa patients. 29 patients with a comparable indication who had to undergo an angiography were chosen. The blood parameters of these patients were determined before and after the angiographic treatment. No provable changes of the thyroid parameters f-T 3 , f-T 4 and TSH were found after the angiography. In case of enzyme activities, the protective enzymes SOD and GSHPX showed no changes, while the concentrations of peroxides and MDA were increased significantly. Corresponding to this, the total antioxidative status and the vitamin E level decreased significantly. Altogether these results stand for a moderate deterioration of the antioxidative protective potential by the highly iodine containing contrast medium. (author)

  15. CONTRAST

    DEFF Research Database (Denmark)

    Kristensen, Thomas Krogsgaard

    2007-01-01

    Dette er en afrapportering fra den årlige CONTRAST workshop, der i 2007 blev afholdt i Yaoundé, Cameroon.......Dette er en afrapportering fra den årlige CONTRAST workshop, der i 2007 blev afholdt i Yaoundé, Cameroon....

  16. Reduction of contrast medium volume in abdominal aorta CTA: Multiphasic injection technique versus a test bolus volume

    Energy Technology Data Exchange (ETDEWEB)

    Nijhof, Wouter H., E-mail: w.h.nijhof@student.utwente.nl [University of Twente, MIRA-Institute for Biomedical Technology and Technical Medicine, P.O. Box 21, 7500 AE Enschede (Netherlands); Vos, Charlotte S. van der, E-mail: c.s.vandervos@student.utwente.nl [University of Twente, MIRA-Institute for Biomedical Technology and Technical Medicine, P.O. Box 21, 7500 AE Enschede (Netherlands); Anninga, Bauke, E-mail: b.anninga@student.utwente.nl [University of Twente, MIRA-Institute for Biomedical Technology and Technical Medicine, P.O. Box 21, 7500 AE Enschede (Netherlands); Jager, Gerrit J., E-mail: g.jager@JBZ.nl [Department of Radiology, Jeroen Bosch Hospital, Henri Dunantstraat 1, 5223 GZ ’s-Hertogenbosch (Netherlands); Rutten, Matthieu J.C.M., E-mail: mj.rutten@online.nl [Department of Radiology, Jeroen Bosch Hospital, Henri Dunantstraat 1, 5223 GZ ’s-Hertogenbosch (Netherlands)

    2013-09-15

    Objective: The purpose of this study is to reduce the administered contrast medium volume in abdominal CTA by using a test bolus injection, with the preservation of adequate quantitative and qualitative vessel enhancement. Study design: For this technical efficacy study 30 patients, who were referred for a CTA examination of the abdominal aorta, were included. Randomly 15 patients were assigned to undergo a multiphasic injection protocol and received 89 mL of contrast medium (Optiray 350) (protocol I). Fifteen patients were assigned to the test bolus injection protocol (protocol II), which implies injection of a 10 mL test bolus of Optiray 350 prior to performing CTA with a 40 mL of contrast medium. Quantitative assessment of vascular enhancement was performed by measuring the amount of Hounsfield Units in the aorta at 30 positions from the celiac trunk to the iliac arteries in both groups. Qualitative assessment was performed by three radiologists who scored the images at a 5-point scale. Results: Quantitative assessment showed that there was no significant difference in vascular enhancement for patients between the two protocols, with mean attenuation values of 280.9 ± 50.84 HU and 258.60 ± 39.28 HU, respectively. The image quality of protocol I was rated 4.31 (range: 3.67/5.00) and of protocol II 4.11 (range: 2.67/5.00). These differences were not statistically significant. Conclusion: This study showed that by using a test bolus injection and the administration of 50 mL of contrast medium overall, CTA of the abdominal aorta can reliably be performed, with regard to quantitative and qualitative adequate vessel enhancement.

  17. Estimation of shear velocity contrast for dipping or anisotropic medium from transmitted Ps amplitude variation with ray-parameter

    Science.gov (United States)

    Kumar, Prakash

    2015-12-01

    Amplitude versus offset analysis of P to P reflection is often used in exploration seismology for hydrocarbon exploration. In the present work, the feasibility to estimate crustal velocity structure from transmitted P to S wave amplitude variation with ray-parameter has been investigated separately for dipping layer and anisotropy medium. First, for horizontal and isotropic medium, the approximation of P-to-s conversion is used that is expressed as a linear form in terms of slowness. Next, the intercept of the linear regression has been used to estimate the shear wave velocity contrast (δβ) across an interface. The formulation holds good for isotropic and horizontal layer medium. Application of such formula to anisotropic medium or dipping layer data may lead to erroneous estimation of δβ. In order to overcome this problem, a method has been proposed to compensate the SV-amplitude using shifted version of SH-amplitude, and subsequently transforming SV amplitudes equivalent to that from isotropic or horizontal layer medium as the case may be. Once this transformation has been done, δβ can be estimated using isotropic horizontal layer formula. The shifts required in SH for the compensation are π/2 and π/4 for dipping layer and anisotropic medium, respectively. The effectiveness of the approach has been reported using various synthetic data sets. The methodology is also tested on real data from HI-CLIMB network in Himalaya, where the presence of dipping Moho has already been reported. The result reveals that the average shear wave velocity contrast across the Moho is larger towards the Indian side compared to the higher Himalayan and Tibetan regions.

  18. Long-term results with a nonionic contrast medium - a clinical experience report

    International Nuclear Information System (INIS)

    Hruby, W.; Stellamor, K.

    1987-01-01

    Between January 1982 and May 1986 more than 50 000 patients were examined radioligically with water-soluble (ionic and nonionic) contrast media at the Department of Radiology Rudolfstiftung, Vienna. 1983 only 2,2% of the contrast agents used were nonionic, in 1985 the share had increased to 53,3%. During this period the rate of drug-related side effects (DRSE) decreased from 6,9% (1983) to 3,3% (1985). From 1983 to 1985 DRSE were observed with 1952 patients after administration of ionic agents, whereas after application of nonionic media adverse reactions occurred in only 6 cases, so that DRSE rates of 6,98% respectively 0,07% resulted for ionic respectively nonionic contrast media. These results are discussed with regard to the physicochemical properties and physiological actions of ionic and nonionic contrast agents. (orig.) [de

  19. Transient global amnesia following cerebral angiography with non-ionic contrast medium

    International Nuclear Information System (INIS)

    Schamschula, R.G.; Soo, M.Y.S.

    1994-01-01

    Transit global amnesia (TGA) is an uncommon syndrome of recent memory deficit and inability to learn new data, usually resolving within 24 hours. Two cases following use of non-ionic contrast media in cerebral angiography are presented. The neuroanatomy of memory is reviewed. Possible aetiologies of TGA in relation to cerebral angiography include ischemia (embolic, arterial spasm), epilepsy that may be primary or tumour-related and direct toxic effects of contrast media. 19 refs., 1 fig

  20. Transient angioedema of small bowel secondary to intravenous iodinated contrast medium

    Directory of Open Access Journals (Sweden)

    Kirankumar N Kulkarni

    2014-01-01

    Full Text Available We report the clinical details and imaging findings of a case of transient angioedema of the small bowel following intravenous administration of non-ionic iodinated contrast material in a 17 year old female with no predisposing risk factors. Findings included long segment, symmetric, circumferential, low-density, bowel wall thickening involving the duodenum, jejunum, and most of the ileum on computed tomography scan obtained at 7 min following intravenous contrast material injection. This entity is self-limiting with a favourable clinical outcome and requires no specific treatment but only aggressive clinical monitoring.

  1. Contrast-enhanced fat saturation magnetic resonance imaging for studying the pathophysiology of osteonecrosis of the hips

    Energy Technology Data Exchange (ETDEWEB)

    Li, K.C.P.; Hiette, P. (St. Joseph' s Hospital and Medical Center, Phoenix, AZ (United States). Dept. of Radiology)

    1992-08-01

    We imaged 75 hips in 40 patients using fat saturation technique before and after intravenous injection of contrast (0.1 mmol/kg gadolinium diethylene triamine penta-acetic acid, Gd-DTPA). Eighteen hips in 11 patients were determined to be osteonecrotic,either by pathologic or clinical examination. In the osteonecrotic hips, three distinct patterns of enhancement were found: (I) focal area outlined by brightly enhancing rim (7 hips); (II) diffuse enhancement in the femoral head and neck extending into the femoral shaft (3 hips); and (III) a combination of patterns I and II (8 hips). Our data support the hypothesis that early nontraumatic osteonecrosis is associated with hyperemia and/or an increase in capillary permeability rather than acute devascularization, and that diffuse marrow edema is the initial finding in early nontraumatic osteonecrosis. (orig.).

  2. Contrast-enhanced fat saturation magnetic resonance imaging for studying the pathophysiology of osteonecrosis of the hips

    International Nuclear Information System (INIS)

    Li, K.C.P.; Hiette, P.

    1992-01-01

    We imaged 75 hips in 40 patients using fat saturation technique before and after intravenous injection of contrast (0.1 mmol/kg gadolinium diethylene triamine penta-acetic acid, Gd-DTPA). Eighteen hips in 11 patients were determined to be osteonecrotic,either by pathologic or clinical examination. In the osteonecrotic hips, three distinct patterns of enhancement were found: (I) focal area outlined by brightly enhancing rim (7 hips); (II) diffuse enhancement in the femoral head and neck extending into the femoral shaft (3 hips); and (III) a combination of patterns I and II (8 hips). Our data support the hypothesis that early nontraumatic osteonecrosis is associated with hyperemia and/or an increase in capillary permeability rather than acute devascularization, and that diffuse marrow edema is the initial finding in early nontraumatic osteonecrosis. (orig.)

  3. An evaluation of ultravist - a contrast medium by Schering in angiography

    International Nuclear Information System (INIS)

    Twarkowski, P.; Woynarowski, M.

    1993-01-01

    An angiography with ''uropolina'' (Polfa), ''hexabrix'' (Byk) and ''ultravist'' (Schering) was performed in 30 patients with various vascular disorders. It has appeared, that low-osmolality contrast media (''hexabrix'') and nonionic ones (''ultravist'') less frequently caused the complications than ''uropolina'', widely used by us. (author)

  4. Contrast-enhanced CISS imaging of cerebellopontine angle tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tozaki, Mitsuhiro; Toyoda, Keiko; Hata, Yuichi; Fukuda, Yasushi; Fukuda, Kunihiko [Jikei Univ., Tokyo (Japan). School of Medicine; Katano, Shuichi

    1999-10-01

    Our purpose of this study was to evaluate the clinical usefulness of contrast-enhanced CISS-3DFT MR imaging for the diagnosis of CP angle tumors. CISS-3DFT MR imaging is expected for screening procedure of acoustic schwannoma because of excellent spatial resolution. Recently, we discovered contrast enhancement effect on CISS sequence in spite of heavily T{sub 2}-weighted images. Fourteen patients with CP angle tumors were performed on a 1.0 T MR unit. Transaxial CISS-3DFT MRI was obtained both before and after intravenous injections of Gd-DTPA. Multiplanar reconstructions (MPRs) were performed in all cases. Contrast enhancement effect of CP angle tumors, and the relationship between tumors and the adjacent cranial nerves were evaluated. Contrast enhancement effect of the tumors was present in all cases in spite of heavily T{sub 2}-weighted images of CISS sequences. In the internal auditory canal, relationship between the tumors and the cranial nerves was demonstrated in 6 cases (6/9). In the cerebellopontine cistern, all cases were demonstrated (11/11). Contrast-enhanced CISS-3DFT MR imaging with a good contrast resolution and an excellent spatial resolution is useful for the diagnosis of CP angle tumors. (author)

  5. 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent

    Energy Technology Data Exchange (ETDEWEB)

    Fink, Christian; Ley, Sebastian; Puderbach, Michael; Plathow, Christian; Kauczor, Hans-Ulrich [Department of Radiology, Innovative Cancer Diagnostic and Therapy, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg (Germany); Bock, Michael [Department of Medical Physics in Radiology, Innovative Cancer Diagnostic and Therapy, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg (Germany)

    2004-07-01

    The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40 ; voxel size: 1.3 x 2.5 x 4.0 mm{sup 3}; TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40 ; voxel size: 0.8 x 1.0 x 1.6 mm{sup 3}) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n=2). SNR measurements were performed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21{+-}8 vs. 13{+-}3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer. (orig.)

  6. Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Jia; Qu, Mingliang; Duan, Xinhui; Takahashi, Naoki; Kawashima, Akira; Leng, Shuai; McCollough, Cynthia H. [Mayo Clinic, Department of Radiology, Rochester, MN (United States)

    2012-12-15

    To develop a dual-energy CT (DECT) method for differentiating uric acid (UA) from non-UA stones in the presence of iodinated contrast medium. Thirty UA and 45 non-UA stones were selected after infra-red spectroscopic analysis and independently placed in a 1.5-ml vial, which was filled first with saline and then with increasing concentrations of iodine. For each condition, tubes were put in a 35-cm water phantom and examined using a dual-source CT system at 100 and 140 kV. Virtual unenhanced images created from CT data sets of the stones in iodine-containing solutions provided position and volume information. This map was used to calculate a CT number ratio to differentiate stone type. A region-growing method was developed to improve the ability to differentiate between UA and non-UA stones with iodinated contrast medium. The sensitivity for detecting UA stones was 100 % for unenhanced images but fell to 18 % with 20 mgI/ml iodine solution and 0 % for higher concentrations. With region growing, the sensitivity for detecting UA stones was increased to 100 %, 82 %, 57 %, 50 % and 21 % for iodine solutions of 20, 40, 60, 80 and 100 mgI/ml. The region-growing method improves differentiation of UA from non-UA stones on contrast-enhanced DECT urograms. (orig.)

  7. Nanotoxic Profiling of Novel Iron Oxide Nanoparticles Functionalized with Perchloric Acid and SiPEG as a Radiographic Contrast Medium

    Directory of Open Access Journals (Sweden)

    Muhamad Idham Mohamed

    2015-01-01

    Full Text Available Emerging syntheses and findings of new metallic nanoparticles (MNPs have become an important aspect in various fields including diagnostic imaging. To date, iodine has been utilized as a radiographic contrast medium. However, the raise concern of iodine threats on iodine-intolerance patient has led to search of new contrast media with lower toxic level. In this animal modeling study, 14 nm iron oxide nanoparticles (IONPs with silane-polyethylene glycol (SiPEG and perchloric acid have been assessed for toxicity level as compared to conventional iodine. The nanotoxicity of IONPs was evaluated in liver biochemistry, reactive oxygen species production (ROS, lipid peroxidation mechanism, and ultrastructural evaluation using transmission electron microscope (TEM. The hematological analysis and liver function test (LFT revealed that most of the liver enzymes were significantly higher in iodine-administered group as compared to those in normal and IONPs groups P<0.05. ROS production assay and lipid peroxidation indicator, malondialdehyde (MDA, also showed significant reductions in comparison with iodine group P<0.05. TEM evaluation yielded the aberration of nucleus structure of iodine-administered group as compared to those in control and IONPs groups. This study has demonstrated the less toxic properties of IONPs and it may postulate that IONPs are safe to be applied as radiographic contrast medium.

  8. Characterisation of urinary stones in the presence of iodinated contrast medium using dual-energy CT: a phantom study

    International Nuclear Information System (INIS)

    Wang, Jia; Qu, Mingliang; Duan, Xinhui; Takahashi, Naoki; Kawashima, Akira; Leng, Shuai; McCollough, Cynthia H.

    2012-01-01

    To develop a dual-energy CT (DECT) method for differentiating uric acid (UA) from non-UA stones in the presence of iodinated contrast medium. Thirty UA and 45 non-UA stones were selected after infra-red spectroscopic analysis and independently placed in a 1.5-ml vial, which was filled first with saline and then with increasing concentrations of iodine. For each condition, tubes were put in a 35-cm water phantom and examined using a dual-source CT system at 100 and 140 kV. Virtual unenhanced images created from CT data sets of the stones in iodine-containing solutions provided position and volume information. This map was used to calculate a CT number ratio to differentiate stone type. A region-growing method was developed to improve the ability to differentiate between UA and non-UA stones with iodinated contrast medium. The sensitivity for detecting UA stones was 100 % for unenhanced images but fell to 18 % with 20 mgI/ml iodine solution and 0 % for higher concentrations. With region growing, the sensitivity for detecting UA stones was increased to 100 %, 82 %, 57 %, 50 % and 21 % for iodine solutions of 20, 40, 60, 80 and 100 mgI/ml. The region-growing method improves differentiation of UA from non-UA stones on contrast-enhanced DECT urograms. (orig.)

  9. Contrast-enhanced magnetic resonance angiography: first-pass arterial enhancement as a function of gadolinium-chelate concentration, and the saline chaser volume and injection rate.

    Science.gov (United States)

    Husarik, Daniela B; Bashir, Mustafa R; Weber, Paul W; Nichols, Eli B; Howle, Laurens E; Merkle, Elmar M; Nelson, Rendon C

    2012-02-01

    To evaluate the effect of the contrast medium (CM) concentration and the saline chaser volume and injection rate on first-pass aortic enhancement characteristics in contrast-enhanced magnetic resonance angiography using a physiologic flow phantom. Imaging was performed on a 3.0-T magnetic resonance system (MAGNETOM Trio, Siemens Healthcare Solutions, Inc, Erlangen, Germany) using a 2-dimensional fast low angle shot T1-weighted sequence (repetition time, 500 milliseconds; echo time, 1.23 milliseconds; flip angle, 8 degrees; 1 frame/s × 60 seconds). The following CM concentrations injected at 2 mL/s were used with 3 different contrast agents (gadolinium [Gd]-BOPTA, Gd-HP-DO3A, Gd-DTPA): 20 mL of undiluted CM (100%) and 80%, 40%, 20%, 10%, 5%, and 2.5% of the full amount, all diluted in saline to a volume of 20 mL to ensure equal bolus volume. The CM was followed by saline chasers of 20 to 60 mL injected at 2 mL/s and 6 mL/s. Aortic signal intensity (SI) was measured, and normalized SI versus time (SI/Tn) curves were generated. The maximal SI (SI(max)), bolus length, and areas under the SI/Tn curve were calculated. Decreasing the CM concentration from 100% to 40% resulted in a decrease of SI(max) to 86.1% (mean). Further decreasing the CM concentration to 2.5% decreased SI(max) to 5.1% (mean). Altering the saline chaser volume had no significant effect on SI(max). Increasing the saline chaser injection rate had little effect (mean increase, 2.2%) on SI(max) when using ≥40% of CM. There was a larger effect (mean increase, 19.6%) when ≤20% of CM were used. Bolus time length was significantly shorter (P < 0.001), and area under the SI/T(n) curve was significantly smaller (P < 0.01) for the CM protocols followed by a saline chaser injected at 6 mL/s compared with a saline chaser injected at 2 mL/s. With 40% of CM and a fast saline chaser, SImax close to that with undiluted CM can be achieved. An increased saline chaser injection rate has a more pronounced effect on

  10. Pulmonary edema following intravenous injection of nonionic low-osmolar contrast medium - appearance on HRCT. A case report

    International Nuclear Information System (INIS)

    Bristedt, P.; Tylen, U.

    1998-01-01

    Pulmonary edema following i.v. contrast medium injection is a rare adverse reaction. We report on a 71-year-old woman who developed pulmonary edema following i.v. injection of iohexol during spiral CT of the thorax. She developed shortness of breath during the injection, and the first radiographic signs of pulmonary edema were visible on CT images 25 s after the onset of injection. On HRCT images 15 min later, marked edema was demonstrated in both lungs in a mosaic pattern of distribution. After appropriate therapy, the patient recovered without sequelae. A repeat CT 6 days later showed complete normalization. (orig.)

  11. MRI with intrathecal MRI gadolinium contrast medium administration: a possible method to assess glymphatic function in human brain

    International Nuclear Information System (INIS)

    Eide, Per Kristian; Ringstad, Geir

    2015-01-01

    Recently, the “glymphatic system” of the brain has been discovered in rodents, which is a paravascular, transparenchymal route for clearance of excess brain metabolites and distribution of compounds in the cerebrospinal fluid. It has already been demonstrated that intrathecally administered gadolinium (Gd) contrast medium distributes along this route in rats, but so far not in humans. A 27-year-old woman underwent magnetic resonance imaging (MRI) with intrathecal administration of gadobutrol, which distributed throughout her entire brain after 1 and 4.5 h. MRI with intrathecal Gd may become a tool to study glymphatic function in the human brain

  12. Cytogenetic analysis of peripheral blood lymphocytes after arteriography (exposure to x-rays and contrast medium)

    International Nuclear Information System (INIS)

    Popova, L.; Hadjidekova, V.; Karadjov, G.; Agova, S.; Traskov, D.; Hadjidekov, V.

    2005-01-01

    Backgrounds. The purpose of our study is to investigate the cytogenetic analysis findings in peripheral blood lymphocytes of 29 patients who had undergone diagnostic radiography. Methods. Peripheral blood samples were taken from 22 patients submitted to renal arteriography and 7 patients submitted to cerebral arteriography (17 male and 12 female, aged between 13-68 years). Cytogenetic analyses of peripheral lymphocytes were performed before the procedure, immediately after and 24 hours later. The entrance skin dose obtained during the whole diagnostic X-ray exposure was measured by thermoluminescent dosimeters and varied between 0.03-0.30 Gy. Both low and high osmolarity contrast media were used. Chromosomal aberrations and micronuclei frequency were used as biomarkers of genotoxicity. Results. The estimated frequency of chromosomal aberrations and micronuclei in the peripheral blood lymphocytes of patients after arteriography examination was significantly higher than the level before the diagnostic exposure. The mean frequency of cells with chromosomal aberrations was nearly double after examination and proved to be constant in the analysis after 24 hours. Conclusions. Radiological diagnostic procedures involving iodinated contrast media as arteriography may cause a significant increase in cytogenetic damage in peripheral blood lymphocytes. (author)

  13. MRI for local staging of endometrial carcinoma: Is endovenous contrast medium administration still needed?

    Energy Technology Data Exchange (ETDEWEB)

    Bonatti, Matteo, E-mail: matteobonatti@hotmail.com [Department of Radiology of Bolzano Central Hospital, 5 Böhler St., 39100 Bolzano (Italy); Stuefer, Josef [Department of Radiology of Bolzano Central Hospital, 5 Böhler St., 39100 Bolzano (Italy); Oberhofer, Nadia [Department of Physics of Bolzano Central Hospital, 5 Böhler St., 39100 Bolzano (Italy); Negri, Giovanni [Department of Pathology of Bolzano Central Hospital, 5 Böhler St., 39100 Bolzano (Italy); Tagliaferri, Tiziana [Department of Gynecology of Bolzano Central Hospital, 5 Böhler St., 39100 Bolzano (Italy); Schifferle, Günther [Department of Radiology of Bolzano Central Hospital, 5 Böhler St., 39100 Bolzano (Italy); Messini, Sergio [Department of Gynecology of Bolzano Central Hospital, 5 Böhler St., 39100 Bolzano (Italy); Manfredi, Riccardo [Department of Radiology of the University of Verona, Piazzale L.A. Scuro 10, 37134 Verona (Italy); Bonatti, Giampietro [Department of Radiology of Bolzano Central Hospital, 5 Böhler St., 39100 Bolzano (Italy)

    2015-02-15

    Highlights: • Intravenous contrast material administration is not routinely indicated for MRI local staging of endometrial carcinoma. • The combination of T2-weighted images with diffusion-weighted images warrants at least the same accuracy as the combination of T2-weighted images with contrast-enhanced T1-weighted images in recognizing deep myometrial invasion and cervical stromal infiltration by endometrial carcinoma. - Abstract: Purpose: To compare the diagnostic performance of T2-weighted images (T2-WI) + contrast-enhanced T1-weighted images (CE T1-WI) with the one of T2-WI + diffusion-weighted images (DWI) in the assessment of myometrial and cervical stromal infiltration by endometrial carcinoma (EC). Materials and methods: Institutional review board approved our retrospective study; requirement for informed consent was waived. 56 patients with histologically proven EC who underwent preoperative MRI and surgery at our Institution over a 34 months period were included. Two radiologists independently evaluated T2-WI + CE T1-WI and T2-WI + DWI of each patient. Confidence in imaging evaluation (0–3), depth of myometrial invasion ( 0.05) whereas both imaging sequences combinations showed the same diagnostic performance in recognizing cervical stromal infiltration (accuracy, sensitivity and specificity of 0.95, 0.98 and 0.80, p > 0.05). Conclusion: T2-WI + DWI can reliably replace the “classical” combination T2-WI + CE T1-WI for local staging of endometrial carcinoma.

  14. [Dynamic MR mammography. Multidimensional visualization of contrast medium enhancement in virtual reality].

    Science.gov (United States)

    Englmeier, K H; Griebel, J; Lucht, R; Knopp, M; Siebert, M; Brix, G

    2000-03-01

    The purpose of this study was the development of a method for fast and efficient analysis of dynamic MR images of the female breast. The image data sets were acquired with a saturation-recovery turbo-FLASH sequence which enables the detection of the kinetics of the contrast agent concentration in the whole breast with a high temporal and spatial resolution. In addition, a morphologic 3D-FLASH data set was acquired. The dynamic image datasets were analyzed by a pharmacokinetic model which enables the representation of the relevant functional tissue information by two parameters. In order to display simultaneously morphologic and functional tissue information, we developed a multidimensional visualization system, which enables a practical and intuitive human-computer interface in virtual reality. The developed system allows the fast and efficient analysis of dynamic MR data sets. An important clinical application is the localization and definition of multiple lesions of the female breast.

  15. Does MRI with oral contrast medium allow single-study depiction of inflammatory bowel disease enteritis and colitis?

    Energy Technology Data Exchange (ETDEWEB)

    Cronin, Carmel G.; Lohan, Derek G.; Browne, Ann Michelle; Roche, Clare; Murphy, Joseph M. [University College Hospital, Department of Radiology, Galway (Ireland)

    2010-07-15

    To assess the feasibility and utility of magnetic resonance (MR) imaging of the bowel in concurrent small- and large-bowel evaluation for the presence of inflammatory bowel disease (IBD). Over a 5-year period, 62 MR examinations performed on 53 patients demonstrated evidence of IBD. Sixteen of these 53 (30.1%) patients had imaging findings of colonic disease and underwent 19 formal MR small bowel examinations. These were further evaluated for bowel distention and image quality. The sensitivity and specificity of the technique compared with colonoscopy as the 'gold standard' was evaluated. Simultaneous imaging of the colon is feasible at MR small bowel follow-through with moderate-to-excellent colonic visibility and colon distention obtained when the contrast medium is present in the colon at the time of image acquisition. MR imaging had a sensitivity of 80% (0.56-0.93), specificity of 100% (0.77-1.00), positive predictive value (PPV) of 1 and a negative predictive value (NPV) of 0.8 for the identification of colitis (based on available concurrent correlation of 38/62 examinations with colonoscopy). Small and large bowel MR imaging with orally consumed contrast medium represents a promising, feasible, non-invasive, non-radiating single mode of assessment of the entire gastrointestinal tract, performed at a single sitting. (orig.)

  16. Does MRI with oral contrast medium allow single-study depiction of inflammatory bowel disease enteritis and colitis?

    International Nuclear Information System (INIS)

    Cronin, Carmel G.; Lohan, Derek G.; Browne, Ann Michelle; Roche, Clare; Murphy, Joseph M.

    2010-01-01

    To assess the feasibility and utility of magnetic resonance (MR) imaging of the bowel in concurrent small- and large-bowel evaluation for the presence of inflammatory bowel disease (IBD). Over a 5-year period, 62 MR examinations performed on 53 patients demonstrated evidence of IBD. Sixteen of these 53 (30.1%) patients had imaging findings of colonic disease and underwent 19 formal MR small bowel examinations. These were further evaluated for bowel distention and image quality. The sensitivity and specificity of the technique compared with colonoscopy as the 'gold standard' was evaluated. Simultaneous imaging of the colon is feasible at MR small bowel follow-through with moderate-to-excellent colonic visibility and colon distention obtained when the contrast medium is present in the colon at the time of image acquisition. MR imaging had a sensitivity of 80% (0.56-0.93), specificity of 100% (0.77-1.00), positive predictive value (PPV) of 1 and a negative predictive value (NPV) of 0.8 for the identification of colitis (based on available concurrent correlation of 38/62 examinations with colonoscopy). Small and large bowel MR imaging with orally consumed contrast medium represents a promising, feasible, non-invasive, non-radiating single mode of assessment of the entire gastrointestinal tract, performed at a single sitting. (orig.)

  17. Utility of vaginal and rectal contrast medium in MRI for the detection of deep pelvic endometriosis

    Energy Technology Data Exchange (ETDEWEB)

    Chassang, M.; Novellas, S.; Bloch-Marcotte, C.; Chevallier, P. [Hopital Archet 2, Service d' Imagerie Diagnostique et Interventionnelle, Centre Hospitalier Regional et Universitaire de Nice, 151 route de Saint Antoine de Ginestiere, B.P. 3079, Nice Cedex 3 (France); Delotte, J.; Bongain, A. [Hopital Archet 2, Service de Gynecologie-Obstetrique, Centre Hospitalier Regional et Universitaire de Nice, 151 route de Saint Antoine de Ginestiere, B.P. 3079, Nice Cedex 3 (France); Toullalan, O. [Hopital de Cannes, Service de Gynecologie, 15 avenue des Broussailles, B.P. 264, Cannes Cedex (France)

    2010-04-15

    To study the sensitivity of MRI performed utilising vaginal and rectal opacification with ultrasound gel in the detection of deep pelvic endometriosis. This was a prospective monocentric study. All patients evaluated by the gynaecologist for pelvic pain, endometriosis or infertility were included. Axial and sagittal T2-weighted images were performed both with and without vaginal and rectal opacification with ultrasound gel. Three radiologists, all blinded, interpreted the images with a minimum of 15 days between the two readings. MRI performance with and without vaginal and rectal opacification was evaluated by calculating sensitivity, specificity and both positive and negative predictive values. Seventy-eight patients were included. Among these, 31 patients had deep pelvic endometriosis of which 24 were confirmed by laparoscopy. Seventy-six locations of deep pelvic endometriosis were discovered on MRI. For the three reviewers there was a significant improvement in sensitivity between pre- and post-contrast MRI (p < 0.0002). Opacification of the vagina and rectum significantly improved the sensitivity of MRI for the detection of deep pelvic endometriosis by expanding the vagina and rectum, thus allowing better delineation of the pelvic organs. This was especially apparent for lesions localised to the vagina and rectovaginal septum. (orig.)

  18. Utility of vaginal and rectal contrast medium in MRI for the detection of deep pelvic endometriosis

    International Nuclear Information System (INIS)

    Chassang, M.; Novellas, S.; Bloch-Marcotte, C.; Chevallier, P.; Delotte, J.; Bongain, A.; Toullalan, O.

    2010-01-01

    To study the sensitivity of MRI performed utilising vaginal and rectal opacification with ultrasound gel in the detection of deep pelvic endometriosis. This was a prospective monocentric study. All patients evaluated by the gynaecologist for pelvic pain, endometriosis or infertility were included. Axial and sagittal T2-weighted images were performed both with and without vaginal and rectal opacification with ultrasound gel. Three radiologists, all blinded, interpreted the images with a minimum of 15 days between the two readings. MRI performance with and without vaginal and rectal opacification was evaluated by calculating sensitivity, specificity and both positive and negative predictive values. Seventy-eight patients were included. Among these, 31 patients had deep pelvic endometriosis of which 24 were confirmed by laparoscopy. Seventy-six locations of deep pelvic endometriosis were discovered on MRI. For the three reviewers there was a significant improvement in sensitivity between pre- and post-contrast MRI (p < 0.0002). Opacification of the vagina and rectum significantly improved the sensitivity of MRI for the detection of deep pelvic endometriosis by expanding the vagina and rectum, thus allowing better delineation of the pelvic organs. This was especially apparent for lesions localised to the vagina and rectovaginal septum. (orig.)

  19. Systemic Hypotension Following Intravenous Administration of Nonionic Contrast Medium During Computed Tomography: Iopromide Versus Iodixanol.

    Science.gov (United States)

    Widmann, Gerlig; Bale, Reto; Ulmer, Hanno; Putzer, Daniel; Schullian, Peter; Wiedermann, Franz-Josef; Lederer, Wolfgang

    2018-03-01

    In light of the increasing number of radiologic interventions performed under general anesthesia, the effects of contrast media (CM) on circulation and organ perfusion are of paramount importance. The objectives of this study were to systematically quantify effects on blood pressure, heart rate, and kidney function following intravenous administration of nonionic CM with normal and low osmolality. In this controlled, double-blinded phase IV clinical trial, 40 consecutive patients were randomly assigned to receive repeated measures of either low-osmolar iopromide or iso-osmolar iodixanol. Normal saline solution (NSS) served as control. Blood pressure and heart rate were measured continuously from 1 minute before until 3 minutes after administration of CM and NSS. Urine output was recorded hourly. Administration of iopromide resulted in systemic hypotension lasting up to 300 seconds (105 ± 61 seconds) with the lowest mean arterial pressure of 39 mm Hg (56.7 ± 12.2 mm Hg). Iopromide caused a systolic/diastolic decrease of 31/26 mm Hg (P .640). Administration of low-osmolar iopromide was followed by a significant transient decrease in blood pressure and a rise in heart rate. Anesthetists and radiologists should be aware of these effects in patients in whom short episodes of disturbed tissue microcirculation may pose a clinical risk.

  20. Contrasting medium and genre on Wikipedia to open up the dominating definition and classification of geoengineering

    Directory of Open Access Journals (Sweden)

    Nils Markusson

    2016-08-01

    Full Text Available Geoengineering is typically defined as a techno-scientific response to climate change that differs from mitigation and adaptation, and that includes diverse individual technologies, which can be classified as either solar radiation management or carbon dioxide removal. We analyse the representation of geoengineering on Wikipedia as a way of opening up this dominating, if contested, model for further debate. We achieve this by contrasting the dominating model as presented in the encyclopaedic article texts with the patterns of hyper-link associations between the articles. Two datasets were created tracing the geoengineering construct on Wikipedia, shedding light on its boundary with its context, as well as on its internal structure. The analysis shows that the geoengineering category tends to be associated on Wikipedia primarily with atmospheric solar radiation management rather than land-based carbon dioxide removal type technologies. The results support the notion that the dominant model of defining and classifying geoengineering technology has been beneficial for solar radiation management type technologies more than for land-based carbon dioxide removal ones. The article also demonstrates that controversy mapping with Wikipedia data affords analysis that can open up dominating definitions and classifications of technologies, and offer resistance to their frequent naturalising and decontextualising tendencies. This work is in line with recent work on digital sociology, but the article contributes a new methodology and reports on the first empirical application of controversy mapping using Wikipedia data to a technology.

  1. MR imaging in recurrent pain after back surgery. A comparative study using standard and high doses of gadolinium contrast agents

    International Nuclear Information System (INIS)

    Aakeson, P.; Jonsson, E.; Holtaas, S.

    1996-01-01

    Purpose: To compare the diagnostic results following injection of (a) a high dose (0.3 mmol/kg b.w.) of gadodiamide injection and (b) the standard dose (0.1 mmol/kg b.w.) of Gd-DTPA, in patients with recurrent symptoms after surgery for lumbar disc herniation. Material and Methods: Twenty patients with recurrent or sustained symptoms after surgery for lumbar disc herniations were examined. MR imaging (0.3 T) was first performed before and after Gd-DTPA at 0.1 mmol/kg b.w., and then within one month (17 patients) or within 3 months (3 patients) before and after gadodiamide injection at 0.3 mmol/kg b.w. The examinations were first evaluated by 2 neuroradiologists blinded to dose but not to patient as the images were presented in pairs. Six months later the same investigators evaluated the examinations again, this time blinded to both dose and patient. Results: At the evaluation in pairs (with the investigators blinded to dose only) the high-dose examinations were considered the most informative (p=0.05). However, at the later evaluation (with the investigators blinded both to dose and patient) no significant difference between high and standard dose was found regarding diagnosis or diagnostic certainty. Conclusion: In this study the high-dose contrast enhancement of MR imaging at 0.3 T did not increase the diagnostic information for differentiating between scar and recurrent hernia. The high-dose images were considered more informative when evaluated in pairs, but gave no additional or different information when evaluated separately. The study also indicated that comparisons in pairs should be interpreted with caution. (orig.)

  2. MR imaging in recurrent pain after back surgery. A comparative study using standard and high doses of gadolinium contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Aakeson, P. [Univ. Hospital, Lund (Sweden). Dept. of Radiology; Annertz, M. [Univ. Hospital, Lund (Sweden). Dept. of Radiology; Kristoffersen, D.T. [Nycomed Imaging AS, Oslo (Norway); Jonsson, E. [Nycomed AB, Stockholm (Sweden); Holtaas, S. [Univ. Hospital, Lund (Sweden). Dept. of Radiology

    1996-11-01

    Purpose: To compare the diagnostic results following injection of (a) a high dose (0.3 mmol/kg b.w.) of gadodiamide injection and (b) the standard dose (0.1 mmol/kg b.w.) of Gd-DTPA, in patients with recurrent symptoms after surgery for lumbar disc herniation. Material and Methods: Twenty patients with recurrent or sustained symptoms after surgery for lumbar disc herniations were examined. MR imaging (0.3 T) was first performed before and after Gd-DTPA at 0.1 mmol/kg b.w., and then within one month (17 patients) or within 3 months (3 patients) before and after gadodiamide injection at 0.3 mmol/kg b.w. The examinations were first evaluated by 2 neuroradiologists blinded to dose but not to patient as the images were presented in pairs. Six months later the same investigators evaluated the examinations again, this time blinded to both dose and patient. Results: At the evaluation in pairs (with the investigators blinded to dose only) the high-dose examinations were considered the most informative (p=0.05). However, at the later evaluation (with the investigators blinded both to dose and patient) no significant difference between high and standard dose was found regarding diagnosis or diagnostic certainty. Conclusion: In this study the high-dose contrast enhancement of MR imaging at 0.3 T did not increase the diagnostic information for differentiating between scar and recurrent hernia. The high-dose images were considered more informative when evaluated in pairs, but gave no additional or different information when evaluated separately. The study also indicated that comparisons in pairs should be interpreted with caution. (orig.).

  3. Contrast enhancement of the cerebrospinal fluid on MRI in two cases of spirochaetal meningitis

    International Nuclear Information System (INIS)

    Good, C.D.; Jaeger, H.R.

    2000-01-01

    We report two patients with meningitis due to spirochaetal infection, both of whom showed diffusely enhancing meninges around the brain and spinal cord. In addition, there was enhancement of the cerebrospinal fluid after intravenous administration of Gd-DTPA. (orig.)

  4. Contrast Medium Induced Nephropathy after Endovascular Stent Graft Placement: An Examination of Its Prevalence and Risk Factors

    International Nuclear Information System (INIS)

    Kawatani, Yohei; Nakamura, Yoshitsugu; Mochida, Yoshihiko; Yamauchi, Naoya; Hayashi, Yujiro; Taneichi, Tetsuyoshi; Ito, Yujiro; Kurobe, Hirotsugu; Suda, Yuji; Hori, Takaki

    2016-01-01

    Endovascular stent graft placement has become a major treatment for thoracic and abdominal aneurysms. While endovascular therapy is less invasive than open surgery, it involves the use of a contrast medium. Contrast media can cause renal impairment, a condition termed as contrast-induced nephropathy (CIN). This study sought to evaluate the incidence and risk factors of CIN following endovascular stent graft placement for aortic aneurysm repair. The study included 167 consecutive patients who underwent endovascular stent graft placement in our hospital from October 2013 to June 2014. CIN was diagnosed using the European Society of Urogenital Radiology criteria. Patients with and without CIN were compared. Chi-squared tests, t-tests, and multivariate logistic regression analyses were performed. Thirteen patients (7.8%) developed CIN. Left ventricular dysfunction and intraoperative blood transfusion were significantly more frequent in the CIN group (P = 0.017 and P = 0.032, resp.). Multivariate analysis showed that left ventricular dysfunction had the strongest influence on CIN development (odds ratio 9.34, P = 0.018, and 95% CI = 1.46–59.7). Patients with CIN also experienced longer ICU and hospital stays. Measures to improve renal perfusion flow should be considered for patients with left ventricular dysfunction who are undergoing endovascular stent graft placement

  5. Dry preparation for virtual CT colonography with fecal tagging using water-soluble contrast medium: initial results

    International Nuclear Information System (INIS)

    Bielen, Didier; Thomeer, Maarten; Vanbeckevoort, Dirk; Marchal, Guy; Kiss, Gabriel; Maes, Frederik; Rutgeerts, Paul

    2003-01-01

    The purpose of this study was to evaluate the feasibility of a dry bowel preparation, i.e. without laxative fluids, for virtual CT colonography (VCTC), and its impact on patient acceptance compared with conventional colonoscopy (CC). A randomly chosen patient population scheduled for CC (n=11) was first submitted to VCTC after a dry preparation, consisting of low-residue meals combined with a small amount of a iodinated water-soluble contrast medium during each meal 3 days before VCTC. In different colon segments and between different persons, the degree of tagging in VCTC was evaluated and graded. Patient acceptance and future preference were assessed for both preparations as well as for both investigations. The mixing of the contrast with the intestinal content results in contrast impregnated stool, the tagged feces. The degree of fecal tagging was good in the majority of the patients and the colonic segments, especially in the descending colon and sigmoid. Furthermore, patient acceptance and preference were clearly in favour of VCTC compared with CC merely because of the non-invasiveness of the dry preparation. Dry bowel preparation and VCTC is a promising approach towards a patient-friendly colon cancer-screening setup. (orig.)

  6. Intravenous contrast ultrasound examination using contrast-tuned imaging (CnTI) and the contrast medium SonoVue for discrimination between benign and malignant adnexal masses with solid components.

    Science.gov (United States)

    Testa, A C; Timmerman, D; Van Belle, V; Fruscella, E; Van Holsbeke, C; Savelli, L; Ferrazzi, E; Leone, F P G; Marret, H; Tranquart, F; Exacoustos, C; Nazzaro, G; Bokor, D; Magri, F; Van Huffel, S; Ferrandina, G; Valentin, L

    2009-12-01

    To determine whether intravenous contrast ultrasound examination is superior to gray-scale or power Doppler ultrasound for discrimination between benign and malignant adnexal masses with complex ultrasound morphology. In an international multicenter study, 134 patients with an ovarian mass with solid components or a multilocular cyst with more than 10 cyst locules, underwent a standardized transvaginal ultrasound examination followed by contrast examination using the contrast-tuned imaging technique and intravenous injection of the contrast medium SonoVue(R). Time intensity curves were constructed, and peak intensity, area under the intensity curve, time to peak, sharpness and half wash-out time were calculated. The sensitivity and specificity with regard to malignancy were calculated and receiver-operating characteristics (ROC) curves were drawn for gray-scale, power Doppler and contrast variables and for pattern recognition (subjective assignment of a certainly benign, probably benign, uncertain or malignant diagnosis, using gray-scale and power Doppler ultrasound findings). The gold standard was the histological diagnosis of the surgically removed tumors. After exclusions (surgical removal of the mass > 3 months after the ultrasound examination, technical problems), 72 adnexal masses with solid components were used in our statistical analyses. The values for peak contrast signal intensity and area under the contrast signal intensity curve in malignant tumors were significantly higher than those in borderline tumors and benign tumors, while those for the benign and borderline tumors were similar. The area under the ROC curve of the best contrast variable with regard to diagnosing borderline or invasive malignancy (0.84) was larger than that of the best gray-scale (0.75) and power Doppler ultrasound variable (0.79) but smaller than that of pattern recognition (0.93). Findings on ultrasound contrast examination differed between benign and malignant tumors but there

  7. 2D and 3D parameter images for analysis of contrast medium enhancement based on dynamic CT and MR

    International Nuclear Information System (INIS)

    Beier, J.; Stroszczynski, C.; Oellinger, H.; Felix, R.; Buege, T.; Fleck, E.

    1998-01-01

    Aim: For dynamic contrast medium (CM) studies, parameter images exploit specific features of the time/intensity curve (TIC) of each pixel and represent these values in a new image. Existing concepts of two-dimensional CM analysis are extended for three-dimensional applications using adequate computer graphic visualization. Results: In first-pass analyses, TMIP and TG allowed the simultaneous or separted presentation of different temporal phases of the CM bolus. Correlation images emphasized regions with similarities to given TIC patterns. Three-dimensional computer graphic techniques enabled (1) anatomical/function mapping of original image and CM accumulation and (2) fused display of both spatial CM enhancement and color-encoded time of TIC peak in one common image. Conclusions: The quantifiction of presence, magnitude, and time-of-peak of CM accumulation in local image regions supports the assessment of vascularization and of ischemic or necrotic areas. (orig./AJ) [de

  8. The effect of contrast medium SonoVue® on the electric charge density of blood cells.

    Science.gov (United States)

    Petelska, Aneta D; Janica, Jacek R; Kotynska, Joanna; Łebkowska, Urszula; Figaszewski, Zbigniew A

    2012-01-01

    The effect of contrast medium SonoVue® on the electric charge density of blood cells (erythrocytes and thrombocytes) was measured using a microelectrophoretic method. We examined the effect of adsorbed H⁺ and OH⁻ ions on the surface charge of erythrocytes or thrombocytes. Surface charge density values were determined from electrophoretic mobility measurements of blood cells performed at various pH levels. The interaction between solution ions and the erythrocyte's or thrombocyte's surface was described by a four-component equilibrium model. The agreement between the experimental and theoretical charge variation curves of the erythrocytes and thrombocytes was good at pH 2-9. The deviation observed at a higher pH may be caused by disregarding interactions between the functional groups of blood cells.

  9. Kinetics of intravenous radiographic contrast medium injections as used on CT: simulation with time delay differential equations in a basic human cardiovascular multicompartment model.

    Science.gov (United States)

    Violon, D

    2012-12-01

    To develop a multicompartment model of only essential human body components that predicts the contrast medium concentration vs time curve in a chosen compartment after an intravenous injection. Also to show that the model can be used to time adequately contrast-enhanced CT series. A system of linked time delay instead of ordinary differential equations described the model and was solved with a Matlab program (Matlab v. 6.5; The Mathworks, Inc., Natick, MA). All the injection and physiological parameters were modified to cope with normal or pathological situations. In vivo time-concentration curves from the literature were recalculated to validate the model. The recalculated contrast medium time-concentration curves and parameters are given. The results of the statistical analysis of the study findings are expressed as the median prediction error and the median absolute prediction error values for both the time delay and ordinary differential equation systems; these are situated well below the generally accepted maximum 20% limit. The presented program correctly predicts the time-concentration curve of an intravenous contrast medium injection and, consequently, allows an individually tailored approach of CT examinations with optimised use of the injected contrast medium volume, as long as time delay instead of ordinary differential equations are used. The presented program offers good preliminary knowledge of the time-contrast medium concentration curve after any intravenous injection, allowing adequate timing of a CT examination, required by the short scan time of present-day scanners. The injected volume of contrast medium can be tailored to the individual patient with no more contrast medium than is strictly needed.

  10. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT--a pooled analysis of two randomized trials

    DEFF Research Database (Denmark)

    Thomsen, Henrik S; Morcos, Sameh K

    2009-01-01

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients...... with glomerular filtration rate (GFR) contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients...... with moderate-to-severe renal failure received a similar IV contrast dose (40 gI). Serum creatinine (SCr) was measured at screening, baseline and 48-72 +/- 6 h after the MDCT examination. Primary CIN outcome was an increase in SCr >or=0.5 mg/dl (>or=44.2 micromol/l) from baseline. The CIN rates were 2...

  11. Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET

    Energy Technology Data Exchange (ETDEWEB)

    Ay, Mohammad R. [Geneva University Hospital, Division of Nuclear Medicine, Geneva (Switzerland); Zaidi, Habib

    2006-11-15

    Quantitative image reconstruction in positron emission tomography (PET) requires an accurate attenuation map of the object under study for the purpose of attenuation correction. Current dual-modality PET/CT systems offer significant advantages over stand-alone PET, including decreased overall scanning time and increased accuracy in lesion localisation and detectability. However, the contamination of CT data with scattered radiation and misclassification of contrast medium with high-density bone in CT-based attenuation correction (CTAC) are known to generate artefacts in the attenuation map and thus the resulting PET images. The purpose of this work was to quantitatively measure the impact of scattered radiation and contrast medium on the accuracy of CTAC. Our recently developed MCNP4C-based Monte Carlo X-ray CT simulator for modelling both fan- and cone-beam CT scanners and the Eidolon dedicated 3D PET Monte Carlo simulator were used to generate realigned PET/CT data sets. The impact of X-ray scattered radiation on the accuracy of CTAC was investigated through simulation of a uniform cylindrical water phantom for both a commercial fan-beam multi-slice and a prototype cone-beam flat panel detector-based CT scanner. The influence of contrast medium was studied by simulation of a cylindrical phantom containing different concentrations of contrast medium. Moreover, an experimental study using an anthropomorphic striatal phantom was conducted for quantitative evaluation of errors arising from the presence of contrast medium by calculating the apparent recovery coefficient (ARC) in the presence of different concentrations of contrast medium. The analysis of attenuation correction factors (ACFs) for the simulated cylindrical water phantom in both fan- and cone-beam CT scanners showed that the contamination of CT data with scattered radiation in the absence of scatter removal causes underestimation of the true ACFs, namely by 7.3% and 28.2% in the centre for the two

  12. Potentials and limitations of low-concentration contrast medium (150 mg iodine/ml) in CT pulmonary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Radon, M.R., E-mail: mark.radon@gmail.co [Department of diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom); Kaduthodil, M.J.; Jagdish, J.; Matthews, S.; Hill, C.; Bull, M.J.; Morcos, S.K. [Department of diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom)

    2011-01-15

    Aim: To assess the feasibility of producing diagnostic multidetector computed tomography (MDCT) pulmonary angiography with low iodine concentration contrast media (150 mg iodine/ml) in patients with suspected acute pulmonary embolism. Materials and methods: Ninety-five randomized patients underwent MDCT (64 row) pulmonary angiography with 100 ml iopromide either at low concentration (LC) of 150 mg iodine/ml (n = 45) or high concentration (HC) of 300 mg iodine/ml (n = 50), delivered at the rate of 5 ml/s via a power injector. Two experienced radiologists, blinded to the concentration used, subjectively assessed the diagnostic quality and confidence using a four-point scale [1 = poor (not diagnostic), 2 = satisfactory, 3 = good, 4 = excellent]. Attenuation values (in HU) were measured in the main proximal branches of the pulmonary arteries. Results: The median diagnostic quality score for both observers was 3.5 (interquartile range 3-4) in the HC group and 2.5 (interquartile range 1.5-3) in the LC group (p < 0.01). The median diagnostic confidence score for both observers was 4 (interquartile range 3-4) in the HC group and 3 (interquartile range 1.5-4) in the LC group (p < 0.01). Both observers rated examinations as diagnostic in 69% of cases in the LC group, compared with 96% of cases in the HC group. Good interobserver agreement was found in both groups (K value 0.72 in the LC group and 0.73 in the HC). Obesity, poor scan timing, and dilution by venous return of non-opacified blood were the main reasons for a reduction in diagnostic quality of examinations in the LC group. Conclusion: Despite a 50% reduction of contrast medium dose in comparison to the standard technique, 150 mg iodine/ml can produce diagnostic MDCT pulmonary angiogram studies in the absence of obesity or high cardiac output and hyper-dynamic pulmonary circulation. Reducing the dose of contrast media would minimize the risk of contrast nephropathy in patients at risk of this complication

  13. Potentials and limitations of low-concentration contrast medium (150 mg iodine/ml) in CT pulmonary angiography

    International Nuclear Information System (INIS)

    Radon, M.R.; Kaduthodil, M.J.; Jagdish, J.; Matthews, S.; Hill, C.; Bull, M.J.; Morcos, S.K.

    2011-01-01

    Aim: To assess the feasibility of producing diagnostic multidetector computed tomography (MDCT) pulmonary angiography with low iodine concentration contrast media (150 mg iodine/ml) in patients with suspected acute pulmonary embolism. Materials and methods: Ninety-five randomized patients underwent MDCT (64 row) pulmonary angiography with 100 ml iopromide either at low concentration (LC) of 150 mg iodine/ml (n = 45) or high concentration (HC) of 300 mg iodine/ml (n = 50), delivered at the rate of 5 ml/s via a power injector. Two experienced radiologists, blinded to the concentration used, subjectively assessed the diagnostic quality and confidence using a four-point scale [1 = poor (not diagnostic), 2 = satisfactory, 3 = good, 4 = excellent]. Attenuation values (in HU) were measured in the main proximal branches of the pulmonary arteries. Results: The median diagnostic quality score for both observers was 3.5 (interquartile range 3-4) in the HC group and 2.5 (interquartile range 1.5-3) in the LC group (p < 0.01). The median diagnostic confidence score for both observers was 4 (interquartile range 3-4) in the HC group and 3 (interquartile range 1.5-4) in the LC group (p < 0.01). Both observers rated examinations as diagnostic in 69% of cases in the LC group, compared with 96% of cases in the HC group. Good interobserver agreement was found in both groups (K value 0.72 in the LC group and 0.73 in the HC). Obesity, poor scan timing, and dilution by venous return of non-opacified blood were the main reasons for a reduction in diagnostic quality of examinations in the LC group. Conclusion: Despite a 50% reduction of contrast medium dose in comparison to the standard technique, 150 mg iodine/ml can produce diagnostic MDCT pulmonary angiogram studies in the absence of obesity or high cardiac output and hyper-dynamic pulmonary circulation. Reducing the dose of contrast media would minimize the risk of contrast nephropathy in patients at risk of this complication

  14. The influence of different contrast medium concentrations and injection protocols on quantitative and clinical assessment of FDG–PET/CT in lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A., E-mail: fverburg@ukaachen.de [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Pietsch, Hubertus [Bayer Pharma AG, Berlin, Müllerstrasse 178, 13353 Berlin (Germany); Palmowski, Moritz [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Mottaghy, Felix M. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany)

    2013-10-01

    Objectives: To compare the effects of two different contrast medium concentrations for use in computed X-ray tomography (CT) employing two different injection protocols on positron emission tomography (PET) reconstruction in combined 2-{sup 18}F-desoxyglucose (FDG) PET/CT in patients with a suspicion of lung cancer. Methods: 120 patients with a suspicion of lung cancer were enrolled prospectively. PET images were reconstructed with the non-enhanced and venous phase contrast CT obtained after injection of iopromide 300 mg/ml or 370 mg/ml using either a fixed-dose or a body surface area adapted injection protocol. Maximum and mean standardized uptake values (SUVmax and SUVmean) and contrast enhancement (HU) were determined in the subclavian vein, ascending aorta, abdominal aorta, inferior vena cava, portal vein, liver and kidney and in the suspicious lung lesion. PET data were evaluated visually for the presence of malignancy and image quality. Results: At none of the sites a significant difference in the extent of the contrast enhancement between the four different protocols was found. However, the variability of the contrast enhancement at several anatomical sites was significantly greater in the fixed dose groups than in the BSA groups for both contrast medium concentrations. At none of the sites a significant difference was found in the extent of the SUVmax and SUVmean increase as a result of the use of the venous phase contrast enhanced CT for attenuation. Visual clinical evaluation of lesions showed no differences between contrast and non-contrast PET/CT (P = 0.32). Conclusions: Contrast enhanced CT for attenuation correction in combined PET/CT in lung cancer affects neither the clinical assessment nor image quality of the PET-images. A body surface adapted contrast medium protocol reduces the interpatient variability in contrast enhancement.

  15. Follow-up of breast lesions detected by MRI not biopsied due to absent enhancement of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Hefler, L.; Koelbl, H. [Department of Obstetrics and Gynecology, Martin Luther University Halle-Wittenberg, Magdeburger Strasse 16, 06112 Halle (Germany); Casselman, J. [Department of Radiology, A.Z. St. Jan, Brugge (Belgium); Amaya, B.; Heinig, A.; Alberich, T.; Heywang-Koebrunner, S.H. [Department of Diagnostic Radiology, Martin Luther University Halle-Wittenberg, Magdeburger Strasse 16, 06112 Halle (Germany)

    2003-02-01

    Our objective was to follow-up patients in whom scheduled MR-guided vacuum biopsies for suspicious lesions were aborted due to absent enhancement of contrast medium. Thirty-seven of 291 scheduled MR-guided vacuum biopsies were aborted. Six cases were lost to follow-up. Two could be unequivocally identified and were nevertheless biopsied. In 25 of 29 patients absent enhancement was confirmed on subsequent studies without compression. Varying hormonal or inflammatory changes between initial MRI and MR-guided vacuum biopsy most probably explain the findings. Enhancement re-appeared on short-term follow-up <6 months without compression in 4 of the 29 patients. Too strong compression during MR-guided vacuum biopsy explains the absence of enhancement in these patients. Of note, on histology, three of these cases proved malignant. We conclude that short-term follow-up without compression is necessary and recommended for all lesions not visible during scheduled MR-guided vacuum biopsy. (orig.)

  16. Effects of changes in analytic variables and contrast medium on estimation of glomerular filtration rates by computed tomography in healthy dogs.

    Science.gov (United States)

    Matsuda, Yuri; Kishimoto, Miori; Kushida, Kazuya; Yamada, Kazutaka; Shimizu, Miki; Itoh, Hiroshi

    2017-09-01

    OBJECTIVE To investigate effects of changes in analytic variables and contrast medium osmolality on glomerular filtration rate estimated by CT (CT-GFR) in dogs. ANIMALS 4 healthy anesthetized Beagles. PROCEDURES GFR was estimated by inulin clearance, and dogs underwent CT-GFR with iodinated contrast medium (iohexol or iodixanol) in a crossover-design study. Dynamic renal CT scanning was performed. Patlak plot analysis was used to calculate GFR with the renal cortex or whole kidney selected as the region of interest. The renal cortex was analyzed just prior to time of the second cortical attenuation peak. The whole kidney was analyzed 60, 80, 100, and 120 seconds after the appearance of contrast medium. Automated GFR calculations were performed with preinstalled perfusion software including 2 noise reduction levels (medium and strong). The CT-GFRs were compared with GFR estimated by inulin clearance. RESULTS There was no significant difference in CT-GFR with iohexol versus iodixanol in any analyses. The CT-GFR at the renal cortex, CT-GFR for the whole kidney 60 seconds after appearance of contrast medium, and CT-GFR calculated by perfusion software with medium noise reduction did not differ significantly from GFR estimated by inulin clearance. The CT-GFR was underestimated at ≥ 80 seconds after contrast medium appearance (whole kidney) and when strong noise reduction was used with perfusion CT software. CONCLUSIONS AND CLINICAL RELEVANCE Selection of the renal cortex as region of interest or use of the 60-second time point for whole-kidney evaluation yielded the best CT-GFR results. The perfusion software used produced good results with appropriate noise reduction. IMPACT FOR HUMAN MEDICINE The finding that excessive noise reduction caused underestimation of CT-GFR suggests that this factor should also be considered in CT-GFR examination of human patients.

  17. Polysorbate 80 and low-osmolality water-soluble contrast medium enema in diagnosis and treatment of faecal obstruction in malignant phaeochromocytoma. Report of a case

    Energy Technology Data Exchange (ETDEWEB)

    Ratcliffe, J.F.

    Stercoral obstruction in a young woman with disseminated phaeochromocytoma was diagnosed and treated successfully using an enema of isosmolar iohexol (Omnipaque) and 1% polysorbate 80 (Tween 80) without complication. Surgical intervention was thus avoided. A low osmolality water-soluble contrast medium (iohexol 150 mg I/ml) with a wetting agent (1% Tween 80) was used because a barium suspension would have inspissated, exacerbating the constipation and a hyperosmolar contrast medium might have precipitated a hypertensive crisis and destablished her critical salt and water balance.

  18. Polysorbate 80 and low-osmolality water-soluble contrast medium enema in diagnosis and treatment of faecal obstruction in malignant phaeochromocytoma

    International Nuclear Information System (INIS)

    Ratcliffe, J.F.

    1986-01-01

    Stercoral obstruction in a young woman with disseminated phaeochromocytoma was diagnosed and treated successfully using an enema of isosmolar iohexol (Omnipaque) and 1% polysorbate 80 (Tween 80) without complication. Surgical intervention was thus avoided. A low osmolality water-soluble contrast medium (iohexol 150 mg I/ml) with a wetting agent (1% Tween 80) was used because a barium suspension would have inspissated, exacerbating the constipation and a hyperosmolar contrast medium might have precipitated a hypertensive crisis and destablished her critical salt and water balance. (orig.)

  19. Clinical experience of adverse drug reaction in gadolinium-DTPA enhancement of MRI

    International Nuclear Information System (INIS)

    Kim, Mi Hyae; Hong, Ju Hee; Lee, Yeon Su; Cha, Kyung Soo; Chang, Suk Il; Lee, Young Chul; Kim, Yeong Soo

    1992-01-01

    Gadopentetate dimenglumine(Gd-DTPA) has low toxicity and good tolerance and it is said that the observed adverse drug reaction of Gd-DTPA is compatible to those of iodinated nonionic contrast media. The overall incidence of adverse drug reaction of Gd-DTPA is even lower than those of iodinated nonionic contrast media. Then, the possibility of potential adverse drug reaction of these contrast media is not fully known and recently, many authors have a growing interest in this point. We have taken 2501 cases of MRI and executed 1467 case of Gd-DTPA enhancement scanning(58.7%) and experienced 12 cases of adverse drug reaction(11 cases: mild reaction, 1 case: severs anaphylactic shock) and the overall incidence of our adverse drug reaction of Gd-DTPA was 0.8%. In conclusion, the adverse drug reaction of Gd-DTPA is not rare and the severe adverse drug reaction of Gd-DTPA may occur. So, the possibility of adverse drug reaction after Gd-DTPA injection should always be kept in mind, especially when the patient has a history of reaction to contrast material, allergy(particularly asthma) and cardiac disease. For the safe use of Gd-DTPA, well trained personnel and nearby emergent care facilities should be available

  20. Clinical experience of adverse drug reaction in gadolinium-DTPA enhancement of MRI

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Hyae; Hong, Ju Hee; Lee, Yeon Su; Cha, Kyung Soo; Chang, Suk Il [Sung Ae Gernral Hospital, Seoul (Korea, Republic of); Lee, Young Chul; Kim, Yeong Soo [Chung Ang University Colege of Medicine, Seoul (Korea, Republic of)

    1992-03-15

    Gadopentetate dimenglumine(Gd-DTPA) has low toxicity and good tolerance and it is said that the observed adverse drug reaction of Gd-DTPA is compatible to those of iodinated nonionic contrast media. The overall incidence of adverse drug reaction of Gd-DTPA is even lower than those of iodinated nonionic contrast media. Then, the possibility of potential adverse drug reaction of these contrast media is not fully known and recently, many authors have a growing interest in this point. We have taken 2501 cases of MRI and executed 1467 case of Gd-DTPA enhancement scanning(58.7%) and experienced 12 cases of adverse drug reaction(11 cases: mild reaction, 1 case: severs anaphylactic shock) and the overall incidence of our adverse drug reaction of Gd-DTPA was 0.8%. In conclusion, the adverse drug reaction of Gd-DTPA is not rare and the severe adverse drug reaction of Gd-DTPA may occur. So, the possibility of adverse drug reaction after Gd-DTPA injection should always be kept in mind, especially when the patient has a history of reaction to contrast material, allergy(particularly asthma) and cardiac disease. For the safe use of Gd-DTPA, well trained personnel and nearby emergent care facilities should be available.

  1. Multi-detector CT urography: effect of oral hydration and contrast medium volume on renal parenchymal enhancement and urinary tract opacification - a quantitative and qualitative analysis

    Energy Technology Data Exchange (ETDEWEB)

    Szolar, Dieter H.; Tillich, Manfred; Preidler, Klaus W. [Diagnostikum Graz-Suedwest, Graz (Austria)

    2010-09-15

    To assess the effect of oral hydration and contrast-medium volume on renal enhancement and urinary tract opacification in multi-detector CT urography. A total of 192 patients were assigned to different protocols with varying doses of contrast agent with and without oral hydration. The attenuation was measured in the renal parenchyma in the unenhanced, nephrographic and excretory phase, and in the urinary tract in excretory phase imaging, respectively. Opacification of the urinary tract was graded on volume rendered images. Oral hydration did not significantly alter renal parenchymal enhancement in both the nephrographic and the excretory phase (p > 0.001), but significantly decreased mean attenuation of the urinary tract in the excretory phase (p {<=} 0.001), and improved continuous opacification of all ureter segments (p < 0.01). Higher volumes of contrast medium improved renal parenchymal enhancement (p {<=} 0.001) and continuous opacification of the urinary tract (p {<=} 0.01). Oral hydration leads to lower attenuation values in the urinary tract but improves the continuous opacification of the tract. Increase in contrast medium volume leads to higher renal parenchymal enhancement as well as to an increased continuous opacification of the urinary tract. Decrease in contrast medium volume cannot be compensated for by oral hydration in terms of parenchymal enhancement. (orig.)

  2. The use of dilute calogen[reg] as a fat density oral contrast medium in upper abdominal computed tomography, compared with the use of water and positive oral contrast media

    International Nuclear Information System (INIS)

    Ramsay, Duncan W.; Markham, Derrian H.; Morgan, Bruno; Rodgers, Peter M.; Liddicoat, Amanda J.

    2001-01-01

    AIM: Oral contrast media are commonly given prior to computed tomography (CT) examination of the upper abdomen. Although positive oral contrast media are normally used, there is increasing interest in using negative agents such as water and less commonly fat density products. The aim of this study was to compare a positive oral contrast medium, water, and a diluted emulsion of arachis oil (Calogen[reg], a fat density food supplement) for assessment of the upper abdomen. MATERIALS AND METHODS: Seventy-one patients referred for upper abdominal CT were randomized to receive either 500 ml water, 2% sodium diatrizoate or a dilute suspension of Calogen[reg]. The CT images were scored independently by three radiologists. Distension and anatomical identification was assessed for the stomach, duodenum and jejunum; with anatomical identification recorded for the pancreas, retroperitoneum, liver, gallbladder and spleen. RESULTS: Dilute Calogen[reg] produced a significant improvement (P < 0.01) in distension and anatomical visualization of the stomach and proximal duodenum. Only minimal differences were demonstrated between the three contrast media for visualization of more distal small bowel or identification of the other upper abdominal viscera. Significantly more artifacts were caused by positive contrast media than with the Calogen[reg] mixture. CONCLUSION: A dilute suspension of Calogen[reg] as an oral contrast medium is recommended when disease is suspected within the stomach or proximal duodenum. Ramsay, D.W. et al. (2001)

  3. Systematic review of current guidelines, and their evidence base, on risk of lactic acidosis after administration of contrast medium for patients receiving metformin.

    Science.gov (United States)

    Goergen, Stacy K; Rumbold, Gregory; Compton, Gregory; Harris, Claire

    2010-01-01

    To systematically review evidence about the relationship between metformin administration and the use of iodinated contrast medium and risk of lactic acidosis (LA) and to assess the quality of five current guidelines for use of contrast medium in patients who are taking metformin. A search strategy was developed by using search termsrelated to metformin, contrast media, and LA. Searches were conducted in MEDLINE (Ovid), all Evidence-based Medicine Reviews (Ovid), EMBASE, and Cochrane library databases and were augmented with searches for evidence-based guidelines on radiology and evidence-based medicine Web sites by using the Google Internet search engine. Guidelines were appraised by two independent reviewers by using the Appraisal of Guidelines Research and Evaluation Collaboration Instrument. Other studies were appraised by using structured appraisal checklists. Five guidelines were identified and five empirical studies met inclusion criteria. All guidelines had poor scores on some Appraisal of Guidelines for Research and Evaluation (AGREE) Collaboration criteria; poorer scores tended to occur in relation to objective assessment of rigor of guideline development, editorial independence, and applicability of the guideline to clinical practice. Lack of agreement was observed among guidelines about the need to stop taking metformin after contrast medium is administered, risk of LA in patients with normal renal function before contrast medium injection, recommended method of measuring renal function, and values used to define abnormal function. The evidence that was used as a basis for determining the guidelines for metformin administration, use of contrast medium, and risk of LA consisted of a limited number of observational studies, including case reports, summaries of case reports, and case series (National Health and Medical Research Council of Australia level IV-V evidence). More important, it was not apparent that a systematic search strategy had been used to

  4. Evaluation of the nephrotoxicity of iodixanol in patients with predisposing factors to contrast medium induced nephropathy referred for contrast enhanced computed tomography

    International Nuclear Information System (INIS)

    Sandstede, Joern J.W.; Roth, Anne; Machann, Wolfram; Kaupert, Christine; Hahn, Dietbert

    2007-01-01

    To determine the risk of developing contrast induced nephropathy (CIN) in intermediate-risk patients receiving iodixanol, an iso-osmolar, dimeric non-ionic contrast agent, for CT in a clinical setting. Hundred consecutive patients referred for a contrast enhanced CT with a serum creatinine concentration > 1.1 mg/dl and/or a glomerular filtration rate (GFR) 2.0 mg/dl and a GFR 25% above baseline within 72 h after contrast administration. Serum creatinine concentration and GFR were 1.40 ± 0.22, 1.29 ± 0.29, and 1.26 ± 0.29 mg/dl and 52.2 ± 13.9, 51.3 ± 21.1, and 51.5 ± 15.1 ml/min on days 0, 3, and 7, respectively. Three out of 99 (3%) patients who received 90-110 ml iodixanol revealed a CIN on day 3 without persistence on day 7. No specific therapy was needed. One out of 99 patients reported an exanthema on days 3 and 7. With the use of iodixanol in intermediate-risk patients, 3% of the patients develop CIN on day 3 without need for a specific therapy or persistence on day 7

  5. Contrast-enhanced MR imaging with fat suppression in adult-onset septic spondylodiscitis

    Energy Technology Data Exchange (ETDEWEB)

    Longo, M.; Granata, F.; Ricciardi, G.K.; Gaeta, M.; Blandino, A. [Institute of Radiological Sciences, University of Messina, Piazza Immacolata di Marmo, 4, 98121 Messina (Italy)

    2003-03-01

    Spinal infections typically involve vertebrae as well as discs, and for this reason they are called septic spondylodiscitis. Magnetic resonance imaging is the most sensitive imaging method for the evaluation of this group of spinal diseases. The use of contrast-enhanced T1-weighted sequences with fat suppression, if correctly applied, may increase information provided by MRI. Firstly, this technique allows the primary vertebral focus, which often precedes disc involvement, to be identified at a very early stage. When the disease spreads, T1-weighted fat-suppressed gadolinium dimeglumine (Gd-DTPA) enhanced images provide macroscopic details of the primary vertebral focus, disc involvement patterns, and pathways of infection diffusion. All this information, when correlated with laboratory tests, may be useful in identifying the infectious agents (tuberculous vs piogenic forms), thus enabling a suitable therapy to be started. This technique is also useful in the assessment of the real extension of the disease, providing a clear depiction of paravertebral space involvement and of psoas muscle abscesses. Dangerous complications, such as meningitis, myelitis, and epidural abscesses, may be more promptly diagnosed and fully evaluated with fat-suppressed post-contrast T1-weighted images. Finally, this imaging technique may help to differentiate infectious processes from degenerative disorders, extradural neoplastic processes, and rheumatic diseases. (orig.)

  6. Facile Synthesis of Gd-Functionalized Gold Nanoclusters as Potential MRI/CT Contrast Agents

    Directory of Open Access Journals (Sweden)

    Wenjun Le

    2016-04-01

    Full Text Available Multi-modal imaging plays a key role in the earlier detection of disease. In this work, a facile bioinspired method was developed to synthesize Gd-functionalized gold nanoclusters (Gd-Au NCs. The Gd-Au NCs exhibit a uniform size, with an average size of 5.6 nm in dynamic light scattering (DLS, which is a bit bigger than gold clusters (3.74 nm, DLS, while the fluorescent properties of Gd-Au NCs are almost the same as that of Au NCs. Moreover, the Gd-Au NCs exhibit a high longitudinal relaxivity value (r1 of 22.111 s−1 per mM of Gd in phosphate-buffered saline (PBS, which is six times higher than that of commercial Magnevist (A complex of gadolinium with a chelating agent, diethylenetriamine penta-acetic acid, Gd-DTPA, r1 = 3.56 mM−1·s−1. Besides, as evaluated by nano single photon emission computed tomography (SPECT and computed tomography (CT the Gd-Au NCs have a potential application as CT contrast agents because of the Au element. Finally, the Gd-Au NCs show little cytotoxicity, even when the Au concentration is up to 250 μM. Thus, the Gd-Au NCs can act as multi-modal imaging contrast agents.

  7. Diagnositc value of 3D-gradient echo dynamic contrast enhanced MRI in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ik; Chung, Soo Young; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Shim, Jeong Won [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    To assess the usefulness of 3D-gradient echo dynamic contrast enhanced MRI (3D-DMRI) in the diagnosis of breast cancer and to determine the most useful parameter for this diagnosis. Using a 1.0T MR unit, (Magnetom, Siemens, Erlaugen, Germany), 3D-DMRI (TR/TE=3D30/12) with Gd-DTPA was performed in 38 cases of breast cancer, 22 of fibroadenoma, and in three normal volunteers. We retrospectively evaluated the findings according to the speed on dynamic study and maximal amount of contrast enhancement during the delayed phase;we calculated the contrast index and morphology of the cancers and compared diagnostic accuracy among these three diagnostic parameters. On conventional spin-echo T1-and T2-weighted images, there was no significant difference of signal intensity between benign fibroadenoma and breast carcinoma. Rapid contrast enhancement (within one minute) was noted in 35 breast cancer lesions (92.1%), but relatively low and slow contrast enhancement (after five minutes) was noted in three such lesions (7.9%). Gradual contrast enhancement was noted in 21 lesions of fibroadenoma(95.5%), but a moderate degree of rapid contrast enhancement (from three to five minutes) was noted in the other case (7.9%). of On the delayed enhanced phase of 3D-DMRI, the maximal amount of contrast enhancement showed no significant difference between fibroadenoma and cancer. On 3D-DMRI, an irregular, spiculated border, with high contrast enhancement was noted in all cases of breast cancer, in particular, irregular thick peripheral contrast enhancement with central necrosis was noted 11cases(28.9%). For the diagnosis of breast cancer, 3D-DMRI is a useful technique. Among the diagnostic criteria of speed, maximal amount of contrast enhancement and morphology, morphologic change after contrast enhancement study was the most useful diagnostic parameter.=20.

  8. Diagnositc value of 3D-gradient echo dynamic contrast enhanced MRI in breast cancer

    International Nuclear Information System (INIS)

    Yang, Ik; Chung, Soo Young; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Shim, Jeong Won

    1997-01-01

    To assess the usefulness of 3D-gradient echo dynamic contrast enhanced MRI (3D-DMRI) in the diagnosis of breast cancer and to determine the most useful parameter for this diagnosis. Using a 1.0T MR unit, (Magnetom, Siemens, Erlaugen, Germany), 3D-DMRI (TR/TE=3D30/12) with Gd-DTPA was performed in 38 cases of breast cancer, 22 of fibroadenoma, and in three normal volunteers. We retrospectively evaluated the findings according to the speed on dynamic study and maximal amount of contrast enhancement during the delayed phase;we calculated the contrast index and morphology of the cancers and compared diagnostic accuracy among these three diagnostic parameters. On conventional spin-echo T1-and T2-weighted images, there was no significant difference of signal intensity between benign fibroadenoma and breast carcinoma. Rapid contrast enhancement (within one minute) was noted in 35 breast cancer lesions (92.1%), but relatively low and slow contrast enhancement (after five minutes) was noted in three such lesions (7.9%). Gradual contrast enhancement was noted in 21 lesions of fibroadenoma(95.5%), but a moderate degree of rapid contrast enhancement (from three to five minutes) was noted in the other case (7.9%). of On the delayed enhanced phase of 3D-DMRI, the maximal amount of contrast enhancement showed no significant difference between fibroadenoma and cancer. On 3D-DMRI, an irregular, spiculated border, with high contrast enhancement was noted in all cases of breast cancer, in particular, irregular thick peripheral contrast enhancement with central necrosis was noted 11cases(28.9%). For the diagnosis of breast cancer, 3D-DMRI is a useful technique. Among the diagnostic criteria of speed, maximal amount of contrast enhancement and morphology, morphologic change after contrast enhancement study was the most useful diagnostic parameter.=20

  9. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [University of Copenhagen, Department of Diagnostic Radiology, Copenhagen University Hospital Herlev, and Department of Diagnostic Sciences, Faculty of Health Sciences, Herlev (Denmark); Morcos, Sameh K. [University of Sheffield, Department of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom)

    2009-04-15

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) <60 ml/min undergoing contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients with moderate-to-severe renal failure received a similar IV contrast dose (40 gI). Serum creatinine (SCr) was measured at screening, baseline and 48-72 {+-} 6 h after the MDCT examination. Primary CIN outcome was an increase in SCr {>=}0.5 mg/dl ({>=}44.2 {mu}mol/l) from baseline. The CIN rates were 2.3% in the total population, 0.6% when GFR >40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  10. Nonlinear image blending for dual-energy MDCT of the abdomen: can image quality be preserved if the contrast medium dose is reduced?

    Science.gov (United States)

    Mileto, Achille; Ramirez-Giraldo, Juan Carlos; Marin, Daniele; Alfaro-Cordoba, Marcela; Eusemann, Christian D; Scribano, Emanuele; Blandino, Alfredo; Mazziotti, Silvio; Ascenti, Giorgio

    2014-10-01

    The objective of this study was to compare the image quality of a dual-energy nonlinear image blending technique at reduced load of contrast medium with a simulated 120-kVp linear blending technique at a full dose during portal venous phase MDCT of the abdomen. Forty-five patients (25 men, 20 women; mean age, 65.6 ± 9.7 [SD] years; mean body weight, 74.9 ± 12.4 kg) underwent contrast-enhanced single-phase dual-energy CT of the abdomen by a random assignment to one of three different contrast medium (iomeprol 400) dose injection protocols: 1.3, 1.0, or 0.65 mL/kg of body weight. The contrast-to-noise ratio (CNR) and noise at the portal vein, liver, aorta, and kidney were compared among the different datasets using the ANOVA. Three readers qualitatively assessed all datasets in a blinded and independent fashion. Nonlinear blended images at a 25% reduced dose allowed a significant improvement in CNR (p < 0.05 for all comparisons), compared with simulated 120-kVp linear blended images at a full dose. No statistically significant difference existed in CNR and noise between the nonlinear blended images at a 50% reduced dose and the simulated 120-kVp linear blended images at a full dose. Nonlinear blended images at a 50% reduced dose were considered in all cases to have acceptable image quality. The dual-energy nonlinear image blending technique allows reducing the dose of contrast medium up to 50% during portal venous phase imaging of the abdomen while preserving image quality.

  11. Preliminary clinical application of contrast-enhanced MR angiography using three-dimensional time-resolved imaging of contrast kinetics

    International Nuclear Information System (INIS)

    Yang Chunshan; Zhang Song; Zhou Kangrong; Liu Shiyuan Xiao Xiangsheng; Wang Jinlin; Li Huimin; Xiao Shan; Gong Wanqing

    2007-01-01

    Objective: To assess the clinical application of contrast-enhanced MR angiography using three-dimensional (3D) time-resolved imaging of contrast kinetics (CE-MRA 3D-TRICKS). Methods: TRICKS is a high temporal resolution (2-6 s) MR angiographic technique using a short TR (2.8- 4.0 ms) and TE (0.9-1.3 ms), partial echo sampling and the central part of the k-space being updated more frequently than the peripheral part of the k-space. Pre-contrast mask 3D images are first acquired and 15-20 sequential 3D images following bolus injection of Gd-DTPA are then acquired. Results: Thirty patients underwent contrast-enhanced MR angiography using TRICKS. Twelve vertebral arteries were well displayed on TRICKS. Seven of them showed normal, bilateral vertebral artery stenosis was shown in 1 case, and unilateral vertebral artery stenosis was shown in 4 wth accompaning ipsilateral carotid artery bifurcation stenosis in one case. Bilateral renal artery showed normal in 4 cases, and the artery in transplanted kidney showed normal in one case and stenosis in another case. The cerebral artery showed normal in 2 cases, sagittal sinus thrombosis was detected in one case and intracranial arteriovenous malformation in one case. Pulmonary artery displayed normal in 3 cases, pulmonary artery thrombosis was seen in one case and pulmonary sequestration's abnormal feeding artery and draining vein was revealed in one case. The feeding artery in left lower limb fibrolipoma was showed in one case. The radial-ulnar artery artificial fistula stenosis was seen in one case, and left antebrachium hemangioma was showed in one case. Conclusion: TRICKS can clearly delineate the whole body vascular system and can reveal any vascular abnormality. It is convenient and with high successful rate, which make it the first method of choice in displaying vascular abnormality. (authors)

  12. Influence of osmolarity of contrast medium and saline flush on computed tomography angiography: Comparison of monomeric and dimeric iodinated contrast media with different iodine concentrations at an identical iodine delivery rate

    International Nuclear Information System (INIS)

    Kishimoto, Miori; Doi, Shoko; Shimizu, Junichiro; Lee, Ki-Ja; Iwasaki, Toshiroh; Miyake, Yoh-Ichi; Yamada, Kazutaka

    2010-01-01

    Purpose: To evaluate the influence of osmolarity of iodinated contrast media and saline flush on the contrast effect in thoracic computed tomography angiography (CTA) at an identical iodine delivery rate (IDR). Materials and methods: Seven beagles were used in a cross-over experiment. The contrast media used were iohexol 350 mgI/ml (IOH350; osmolarity 844 mmol/kg) and iodixanol 320 mgI/ml (IDX320; osmolarity 290 mmol/kg). Each contrast medium was administered to groups with and without saline flush at 40.0 mgI/kg/s for all experiments. Dynamic CT scanning was performed at the ninth thoracic vertebra level. The peak value, area under the curve (AUC), and time to peak (TTP) were calculated from the time attenuation curves of the pulmonary artery and aorta. Results: There was no significant difference between IOH350 and IDX320 with or without saline flush in the peak values for the pulmonary artery and aorta. AUC was significantly higher in groups with saline flush for both contrast media and arteries (p < 0.05) with no significant difference between contrast media. TTP was significantly longer in groups with saline flush than without saline flush for both contrast media and arteries (p < 0.05), with no significant difference between contrast media. Conclusions: There were no significant differences in the contrast effects of monomeric IOH350 and dimeric IDX320 in thoracic CTA when used at an identical IDR. Moreover, saline flush prolonged the peak duration at 600 mgI/kg.

  13. Influence of osmolarity of contrast medium and saline flush on computed tomography angiography: Comparison of monomeric and dimeric iodinated contrast media with different iodine concentrations at an identical iodine delivery rate

    Energy Technology Data Exchange (ETDEWEB)

    Kishimoto, Miori, E-mail: miori@mx6.et.tiki.ne.j [Department of Clinical Veterinary Science, Obihiro University of Agriculture and Veterinary Medicine, Nishi 2-11 Inada-cho, Obihiro 080-8555 (Japan); Doi, Shoko, E-mail: s16024@st.obihiro.ac.j [Department of Clinical Veterinary Science, Obihiro University of Agriculture and Veterinary Medicine, Nishi 2-11 Inada-cho, Obihiro 080-8555 (Japan); Shimizu, Junichiro, E-mail: s01163@st.obihiro.ac.j [Department of Clinical Veterinary Science, Obihiro University of Agriculture and Veterinary Medicine, Nishi 2-11 Inada-cho, Obihiro 080-8555 (Japan); Lee, Ki-Ja, E-mail: s01173@st.obihiro.ac.j [Department of Clinical Veterinary Science, Obihiro University of Agriculture and Veterinary Medicine, Nishi 2-11 Inada-cho, Obihiro 080-8555 (Japan); Iwasaki, Toshiroh, E-mail: bpag2180@cc.tuat.ac.j [Department of Veterinary Internal Medicine, Tokyo University of Agriculture and Technology, Saiwai-cho, 3-5-8, Fuchu 183-8509 (Japan); Miyake, Yoh-Ichi, E-mail: miyake@obihiro.ac.j [Department of Clinical Veterinary Science, Obihiro University of Agriculture and Veterinary Medicine, Nishi 2-11 Inada-cho, Obihiro 080-8555 (Japan); Yamada, Kazutaka, E-mail: kyamada@obihiro.ac.j [Department of Clinical Veterinary Science, Obihiro University of Agriculture and Veterinary Medicine, Nishi 2-11 Inada-cho, Obihiro 080-8555 (Japan)

    2010-10-15

    Purpose: To evaluate the influence of osmolarity of iodinated contrast media and saline flush on the contrast effect in thoracic computed tomography angiography (CTA) at an identical iodine delivery rate (IDR). Materials and methods: Seven beagles were used in a cross-over experiment. The contrast media used were iohexol 350 mgI/ml (IOH350; osmolarity 844 mmol/kg) and iodixanol 320 mgI/ml (IDX320; osmolarity 290 mmol/kg). Each contrast medium was administered to groups with and without saline flush at 40.0 mgI/kg/s for all experiments. Dynamic CT scanning was performed at the ninth thoracic vertebra level. The peak value, area under the curve (AUC), and time to peak (TTP) were calculated from the time attenuation curves of the pulmonary artery and aorta. Results: There was no significant difference between IOH350 and IDX320 with or without saline flush in the peak values for the pulmonary artery and aorta. AUC was significantly higher in groups with saline flush for both contrast media and arteries (p < 0.05) with no significant difference between contrast media. TTP was significantly longer in groups with saline flush than without saline flush for both contrast media and arteries (p < 0.05), with no significant difference between contrast media. Conclusions: There were no significant differences in the contrast effects of monomeric IOH350 and dimeric IDX320 in thoracic CTA when used at an identical IDR. Moreover, saline flush prolonged the peak duration at 600 mgI/kg.

  14. Effects of a dimeric vs a monomeric nonionic contrast medium on renal function in patients with mild to moderate renal insufficiency: a double-blind, randomized clinical trial

    Energy Technology Data Exchange (ETDEWEB)

    Carraro, M.; Malalan, F.; Antonione, R.; Faccini, L. [Institute of Medicina Clinica, Ospedale di Cattinara, University of Trieste, Strada di Fiume 447, I-34 149 Trieste (Italy); Stacul, F.; Cova, M.; Petz, S.; Assante, M.; Dalla Palma, L. [Institute of Radiology, Ospedale di Cattinara, University of Trieste, Strada di Fiume 447, I-34 149 Trieste (Italy); Grynne, B.; Haider, T. [Nycomed Imaging AS, Nycoveien 1-2, N-0401 Oslo (Norway)

    1998-02-01

    The efficacy and safety of nonionic dimeric contrast media in subjects with impaired renal function is largely unknown. The present study was aimed at determining the risk of tubular nephrotoxicity in patients with mild to moderate renal insufficiency who underwent intravenous urography (IVU) with the nonionic dimeric contrast agent iodixanol (Visipaque, Nycomed Imaging, Oslo, Norway). In a double-blind protocol 64 patients (55 males; mean age 68.3 years) with serum creatinine between 135 and 265 {mu}mol/l who were to undergo IVU were randomized to receive iodixanol (a nonionic dimer) or iopromide (a nonionic monomer), 600 mg I/kg b. w. Renal function was evaluated before and 1 h, 6 h, 24 h, 48 h and 7 days after IVU with analysis of serum creatinine, urinary enzymes alanylaminopeptidase and N-acetyl-{beta}-glucosaminidase, and urinary microproteins {alpha}-1-microglobulin and albumin. Renal function remained stable in both contrast medium groups during the follow-up period. No statistically significant differences were observed between the monomer and the dimer in terms of urinary enzyme and microprotein excretion or serum creatinine. Transient radiocontrast-induced nephropathy developed in 1 patient who had received iodixanol. The administration of the nonionic dimeric contrast medium iodixanol, or of the nonionic monomer iopromide, entailed a low nephrotoxic potential in patients with mild to moderate renal insufficiency undergoing excretory urography. (orig.) With 2 figs., 1 tab., 13 refs.

  15. Evaluation of Tumor Angiogenesis with a Second-Generation US Contrast Medium in a Rat Breast Tumor Model

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Eun Young [Samsung Medical Center, Sungkyunkwan University School of Medicine (Korea, Republic of); Lee, Sang Hoon; Kim, Hak Hee; Kim, Sung Moon; Shin, Myung Jin; Kim, Nam Kug; Gong, Gyung Yub [Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2008-06-15

    Tumor angiogenesis is an important factor for tumor growth, treatment response and prognosis. Noninvasive imaging methods for the evaluation of tumor angiogenesis have been studied, but a method for the quantification of tumor angiogenesis has not been established. This study was designed to evaluate tumor angiogenesis in a rat breast tumor model by the use of a contrast enhanced ultrasound (US) examination with a second-generation US contrast agent. The alkylating agent 19N-ethyl-N-nitrosourea (ENU) was injected into the intraperitoneal cavity of 30-day-old female Sprague-Dawley rats. Three to four months later, breast tumors were detected along the mammary lines of the rats. A total of 17 breast tumors larger than 1 cm in nine rats were evaluated by gray-scale US, color Doppler US and contrast-enhanced US using SonoVue. The results were recorded as digital video images; time-intensity curves and hemodynamic parameters were analyzed. Pathological breast tumor specimens were obtained just after the US examinations. The tumor specimens were stained with hematoxylin and eosin (H and E) and the expression of CD31, an endothelial cell marker, was determined by immunohistochemical staining. We also evaluated the pathological diagnosis of the tumors and the microvessel density (MVD). Spearman's correlation and the Kruskal-Wallis test were used for the analysis. The pathological diagnoses were 11 invasive ductal carcinomas and six benign intraductal epithelial proliferations. The MVD did not correlate with the pathological diagnosis. However, blood volume (BV) showed a statistically significant correlation with MVD (Spearman's correlation, p < 0.05). Contrast-enhanced US using a second-generation US contrast material was useful for the evaluation of tumor angiogenesis of breast tumors in the rat.

  16. Low contrast medium-volume third-generation dual-source computed tomography angiography for transcatheter aortic valve replacement planning

    Energy Technology Data Exchange (ETDEWEB)

    Felmly, Lloyd M. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiothoracic Surgery, Department of Surgery, Charleston, SC (United States); De Cecco, Carlo N.; Varga-Szemes, Akos; McQuiston, Andrew D. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Schoepf, U.J.; Litwin, Sheldon E.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital of Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2017-05-15

    To investigate feasibility, image quality and safety of low-tube-voltage, low-contrast-volume comprehensive cardiac and aortoiliac CT angiography (CTA) for planning transcatheter aortic valve replacement (TAVR). Forty consecutive TAVR candidates prospectively underwent combined CTA of the aortic root and vascular access route (270 mgI/ml iodixanol). Patients were assigned to group A (second-generation dual-source CT [DSCT], 100 kV, 60 ml contrast, 4.0 ml/s flow rate) or group B (third-generation DSCT, 70 kV, 40 ml contrast, 2.5 ml/s flow rate). Vascular attenuation, noise, signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were compared. Subjective image quality was assessed by two observers. Estimated glomerular filtration (eGFR) at CTA and follow-up were measured. Besides a higher body-mass-index in group B (24.8±3.8 kg/m{sup 2} vs. 28.1±5.4 kg/m{sup 2}, P=0.0339), patient characteristics between groups were similar (P≥0.0922). Aortoiliac SNR (P=0.0003) was higher in group B. Cardiac SNR (P=0.0003) and CNR (P=0.0181) were higher in group A. Subjective image quality was similar (P≥0.213) except for aortoiliac image noise (4.42 vs. 4.12, P=0.0374). TAVR-planning measurements were successfully obtained in all patients. There were no significant changes in eGFR among and between groups during follow-up (P≥0.302). TAVR candidates can be safely and effectively evaluated by a comprehensive CTA protocol with low contrast volume using low-tube-voltage acquisition. (orig.)

  17. Barium sulfate aspiration: Severe chemical pneumonia induced by a massive reflux of contrast medium during small bowel barium enema.

    Science.gov (United States)

    Zhang, Lin; Yang, Yi; Zhang, Ji; Zhou, Xiaowei; Dong, Hongmei; Zhou, Yiwu

    2015-08-01

    Barium contrast radiography is a conventional procedure aimed at revealing lesions of the alimentary tract using barium sulfate on X-ray irradiation. Although it is widely used in clinics, adverse effects and complications are observed, such as anaphylaxis, granuloma, fecalithes, abdomen-leaking, embolism, bacterial contamination, and aspiration. We report a case of death due to a massive barium sulfate aspiration resulted from an air-barium double contrast enema radiography. A 25-year-old female patient was hospitalized with symptoms of abdominal distention, nausea, vomiting and diarrhea for three days. A progressive respiratory distress presented only 1h after a small bowel air-barium double contrast enema. The patient died 11h later. The result of autopsy revealed the cause of death to be severe chemical pneumonitis induced by gastric fluid which was aspirated into her lungs. Barium sulfate is generally recognized to be chemically inert for the respiratory system, but a mixture of barium sulfate with gastric contents is fatal. Here we intend to suggest that, when determining the potential cause of death, medical examiners should consider a patient's status quo as well as the possible adverse effects and complications caused by the barium sulfate preparation during gastrointestinal radiography. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Ultrastructural study on the effects of retrograde infusion of water-soluble contrast medium the rabbit submandibular gland

    International Nuclear Information System (INIS)

    Kim, Eun Kyung; Park, Tae Won

    1987-01-01

    The author observed the effects of retrograde infusion of water soluble contrast media (Telebrix 30) on the rabbit submandibular glands and compared the effects of different degrees of filling. 26 rabbit were divided into 2 group of 1 2 each as experimental and 1 group of 2 as normal controls. One experimental group was filed with 0.2 ml and the other with 0.4 ml. Right submandibular gland of each rabbit was infused with contrast media and left one with physiologic saline as a ex perimental control, at a constant rate of 0.12 ml/min. Using an infusion pump via the main excretory duct. Immediately after the inclusion of contrast media, oblique lateral radiographs of the glands were made with occlusal film in order to confirm the glandular filling. The rabbit were sacrificed after varying periods (1, 8, 24 hours and 3, 6, 10 days) and the tissues were prepared for light and electron microscopic examination. The results were as follows: 1. In glands filled with 0.2 ml contrast media, the initial changes were a few vacuole formation in the acini and slight dilation of the intralobular duct. The moderately severe changes such as vacuole formation in the acini, the abnormal substructure within the secretory granule, dilation of acinar and intercalated duct lumen, scalloping of striated duct lumen and inflammatory cell infiltrate were observed at 3 days. The general appearance was successively recovered, so the tissue had a normal appearance at 10 days. 2. In glands filled with 0.4 ml contrast media, the most prominent alterations such as severe acinar atrophy, decreased number of secretory granules, proliferation of connective tissue stroma and pronounced inflammatory cell infiltrates appeared at 6 days. Although the general appearance returned to be almost normal at 10 days, acinar cells showed some atrophy and decreased secretory granules. 3. In glands subjected to 0.4 ml infusion, the alterations were more severe and recovery was slower than those seen in the glands

  19. The role of dual energy CT in differentiating between brain haemorrhage and contrast medium after mechanical revascularisation in acute ischaemic stroke

    International Nuclear Information System (INIS)

    Tijssen, M.P.M.; Stadler, A.A.R.; Zwam, W. van; Graaf, R. de; Postma, A.A.; Hofman, P.A.M.; Oostenbrugge, R.J. van; Klotz, E.; Wildberger, J.E.

    2014-01-01

    To assess the feasibility of dual energy computed tomography (DE-CT) in intra-arterially treated acute ischaemic stroke patients to discriminate between contrast extravasation and intracerebral haemorrhage. Thirty consecutive acute ischaemic stroke patients following intra-arterial treatment were examined with DE-CT. Simultaneous imaging at 80 kV and 140 kV was employed with calculation of mixed images. Virtual unenhanced non-contrast (VNC) images and iodine overlay maps (IOM) were calculated using a dedicated brain haemorrhage algorithm. Mixed images alone, as ''conventional CT'', and DE-CT interpretations were evaluated and compared with follow-up CT. Eight patients were excluded owing to a lack of follow-up or loss of data. Mixed images showed intracerebral hyperdense areas in 19/22 patients. Both haemorrhage and residual contrast material were present in 1/22. IOM suggested contrast extravasation in 18/22 patients; in 16/18 patients this was confirmed at follow-up. The positive predictive value (PPV) of mixed imaging alone was 25 %, with a negative predictive value (NPV) of 91 % and accuracy of 63 %. The PPV for detection of haemorrhage with DE-CT was 100 %, with an NPV of 89 % and accuracy improved to 89 %. Dual energy computed tomography improves accuracy and diagnostic confidence in early differentiation between intracranial haemorrhage and contrast medium extravasation in acute stroke patients following intra-arterial revascularisation. (orig.)

  20. Dynamic contrast-enhanced magnetic resonance imaging of the wrist in early arthritis

    Directory of Open Access Journals (Sweden)

    M.A. Cimmino

    2011-09-01

    Full Text Available Objectives: MRI has been proposed as the imaging method of choice to evaluate the long-term outcome in patients with early arthritis. The role of dynamic MRI, performed at presentation, in predicting the outcome of patients with early arthritis has been addressed in the present study. Methods: 39 patients with early arthritis, involving at least one wrist, were studied with clinical visits and laboratory investigations, every 3 months. Dynamic MRI was performed with a low-field (0.2T, extremity-dedicated machine (Artoscan, Esaote, Genova, Italy equipped with a permanent magnet and with a dedicated hand and wrist coil. During the intravenous injection of Gd-DTPA, twenty consecutive fast images of 3 slices of the wrist were acquired. The synovial contrast enhancement ratio was calculated both as rate of early enhancement (REE per second during the first 55” and as relative enhancement (RE at t seconds. Results: In our cohort of patients, REE and RE were significantly lower than those observed in a historical cohort of 36 patients with active rheumatoid arthritis. In univariate analysis, low RE predicted complete remission of arthritis. In multivariate analysis, fulfillment of RA criteria during follow-up was predicted by high RE. The need for immunosuppressive treatment at the end of follow-up was predicted by both low RE and high REE. Conclusions: Dynamic MRI may be used to predict several outcomes of early arthritis involving the wrist

  1. Does the MRI or MRI contrast medium gadopentetate dimeglumine change the oxidant and antioxidant status in humans?

    International Nuclear Information System (INIS)

    Olmaz, Refik; Oguz, Ebru Gok; Kiykim, Ahmet; Turgutalp, Kenan; Horoz, M.; Ozhan, Onur; Muslu, Necati; Sungur, Mehmet

    2013-01-01

    Background: It has become evident that gadolinium-based contrast agents (GBCA) may have nephrotoxic potential. Oxidative stress is one of the most important pathways in the pathogenesis of iodinated contrast-induced nephropathy. Purpose: To investigate the effects of static magnetic fields and gadopentetate dimeglumine (Magnevist) on oxidant/antioxidant status via measurement of total antioxidant capacity (TAC), total oxidant status (TOS), and serum malondialdehide (MDA). Material and Methods: Two age- and sex-matched groups of patients not under oxidative stress conditions that underwent magnetic resonance imaging (MRI) were recruited to this study. While contrast-enhanced (Magnevist, 0.2 mmol/kg) MRI was performed in group 1, MRI without GBCA was performed in group 2. Fasting blood glucose, C-reactive protein, serum creatinine, liver enzymes, uric acid, and lipid parameters were examined in all patients. Peripheral venous blood samples in order to determine TAC, TOS, and MDA were collected before and 6, 24, and 72 h after the MRI procedures. The TOS:TAC ratio was used as the oxidative stress index (OSI). Patients were followed up to 72 h. Results: There were no significant changes in serum TAC, TOS, and MDA levels (Δ s erum T AC, Δ s erum T OS, and Δ M DA) in either group 6, 24, or 72 h after the procedures (P > 0.05). Furthermore, OSI did not change after the procedures in either group (P > 0.05). Conclusion: Magnetic field and gadopentetate dimeglumine (Magnevist) do not change the oxidant or antioxidant status at a dose of 0.2 mmol/kg

  2. Does the MRI or MRI contrast medium gadopentetate dimeglumine change the oxidant and antioxidant status in humans?

    Energy Technology Data Exchange (ETDEWEB)

    Olmaz, Refik; Oguz, Ebru Gok; Kiykim, Ahmet; Turgutalp, Kenan [Dept. of Internal Medicine, Div. of Nephrology, School of Medicine, Mersin Univ., Mersin (Turkey)], e-mail: k.turgutalp@hotmail.com; Horoz, M. [Dept. of Internal Medicine, Div. of Nephrology, School of Medicine, Harran Univ., Sanliurfa (Turkey); Ozhan, Onur [Dept. of Internal Medicine, Div. of Endocrinology and Metabolism, School of Medicine, Mersin Univ., Mersin (Turkey); Muslu, Necati [Dept. of Biochemistry, School of Medicine, Mersin Univ., Mersin (Turkey); Sungur, Mehmet [Dept. of Biostatistics, School of Medicine, Mersin Univ., Mersin (Turkey)

    2013-02-15

    Background: It has become evident that gadolinium-based contrast agents (GBCA) may have nephrotoxic potential. Oxidative stress is one of the most important pathways in the pathogenesis of iodinated contrast-induced nephropathy. Purpose: To investigate the effects of static magnetic fields and gadopentetate dimeglumine (Magnevist) on oxidant/antioxidant status via measurement of total antioxidant capacity (TAC), total oxidant status (TOS), and serum malondialdehide (MDA). Material and Methods: Two age- and sex-matched groups of patients not under oxidative stress conditions that underwent magnetic resonance imaging (MRI) were recruited to this study. While contrast-enhanced (Magnevist, 0.2 mmol/kg) MRI was performed in group 1, MRI without GBCA was performed in group 2. Fasting blood glucose, C-reactive protein, serum creatinine, liver enzymes, uric acid, and lipid parameters were examined in all patients. Peripheral venous blood samples in order to determine TAC, TOS, and MDA were collected before and 6, 24, and 72 h after the MRI procedures. The TOS:TAC ratio was used as the oxidative stress index (OSI). Patients were followed up to 72 h. Results: There were no significant changes in serum TAC, TOS, and MDA levels ({Delta}{sub s}erum{sub T}AC, {Delta}{sub s}erum{sub T}OS, and {Delta}{sub M}DA) in either group 6, 24, or 72 h after the procedures (P > 0.05). Furthermore, OSI did not change after the procedures in either group (P > 0.05). Conclusion: Magnetic field and gadopentetate dimeglumine (Magnevist) do not change the oxidant or antioxidant status at a dose of 0.2 mmol/kg.

  3. Pre-Interventional Kynurenine Predicts Medium-Term Outcome after Contrast Media Exposure Due to Coronary Angiography.

    Science.gov (United States)

    Reichetzeder, Christoph; Heunisch, Fabian; Einem, Gina von; Tsuprykov, Oleg; Kellner, Karl-Heinz; Dschietzig, Thomas; Kretschmer, Axel; Hocher, Berthold

    2017-01-01

    Contrast induced acute kidney injury (CI-AKI) remains a serious complication of contrast media enhanced procedures like coronary angiography. There is still a lack of established biomarkers that help to identify patients at high risk for short and long-term complications. The aim of the current study was to evaluate plasma kynurenine as a predictive biomarker for CI-AKI and long-term complications, measured by the combined endpoint "major adverse kidney events" (MAKE) up to 120 days after CM application. In this prospective cohort study 245 patients undergoing coronary angiography were analyzed. Blood samples were obtained at baseline, 24h and 48h after contrast media (CM) application to diagnose CI-AKI. Patients were followed for 120 days for adverse clinical events including death, the need for dialysis, and a doubling of plasma creatinine. Occurrence of any of these events was summarized in the combined endpoint MAKE. Preinterventional plasma kynurenine was not associated with CI-AKI. Patients who later developed MAKE displayed significantly increased preinterventional plasma kynurenine levels (p<0.0001). ROC analysis revealed that preinterventional kynurenine is highly predictive for MAKE (AUC=0.838; p<0.0001). The optimal cutoff was found at ≥3.5 µmol/L Using this cutoff, the Kaplan-Meier estimator demonstrated that concentrations of plasma kynurenine ≥3.5 µmol/L were significantly associated with a higher prevalence of MAKE until follow up (p<0.0001). This association remained significant in multivariate Cox regression models adjusted for relevant factors of long-term renal outcome. Preinterventional plasma kynurenine might serve as a highly predictive biomarker for MAKE up to 120 days after coronary angiography. © 2017 The Author(s). Published by S. Karger AG, Basel.

  4. Low-dose triple-rule-out using 320-row-detector volume MDCT - less contrast medium and lower radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Durmus, Tahir; Lembcke, Alexander; Muehler, Matthias R.; Hamm, Bernd; Hein, Patrick A. [Charite - University Hospital Berlin, Department of Radiology, Berlin (Germany); Rogalla, Patrik [Universitiy of Toronto, Department of Medical Imaging, Toronto, ON (Canada)

    2011-07-15

    To investigate image quality of triple-rule-out (TRO) computed tomography (CT) using a 320-row-detector CT system with substantially reduced contrast medium volume at 100 kV. Forty-six consecutive patients with noncritical, acute chest pain underwent 320-row-detector CT using a two-step TRO protocol consisting of a non-spiral, non-gated chest CT acquisition (150 mA) followed by a non-spiral, electrocardiography-gated cardiac acquisition (200-500 mA based on body mass index (BMI)). Data were acquired using a biphasic injection protocol with a total iodinated contrast medium volume of 60 ml (370 mg/ml). Vessel attenuation and effective doses were recorded. Image quality was scored independently by two readers. Mean attenuation was 584 {+-} 114 Hounsfield units (HU) in the ascending aorta, 335 {+-} 63HU in the aortic arch, 658 {+-} 136HU in the pulmonary trunk, and 521 {+-} 97HU and 549 {+-} 102HU in the right and left coronary artery, respectively. In all but one patient, attenuation and image quality allowed accurate visualization of the pulmonary arteries, thoracic aorta, and coronary arteries in a single examination. Ninety-six percent of all coronary artery segments were rated diagnostic. Radiation exposure ranged between 2.0 and 3.3 mSv. Using 320-row-detector CT the investigated low-dose TRO protocol resulted in excellent opacification and image quality with substantial reduction of contrast medium volume compared to recently published TRO protocols. (orig.)

  5. Minimizing Contrast Medium Doses to Diagnose Pulmonary Embolism with 80-kVp Multidetector Computed Tomography in Azotemic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Holmquist, F. (Dept. of Diagnostic Radiology, Malmoe Univ. Hospital, Univ. of Lund, Malmoe (Sweden)); Hansson, K.; Pasquariello, F. (Dept. of Internal Medicine, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden)); Bjoerk, J. (Competence Center for Clinical Research, Univ. Hospital, Univ. of Lund, Lund (Sweden)); Nyman, U. (Dept. of Radiology, Lasarettet Trelleborg, Univ. of Lund, Trelleborg (Sweden))

    2009-02-15

    Background: In diagnosing acute pulmonary embolism (PE) in azotemic patients, scintigraphy and magnetic resonance imaging are frequently inconclusive or not available in many hospitals. Computed tomography is readily available, but relatively high doses (30-50 g I) of potentially nephrotoxic iodine contrast media (CM) are used. Purpose: To report on the diagnostic quality and possible contrast-induced nephropathy (CIN) after substantially reduced CM doses to diagnose PE in azotemic patients using 80-peak kilovoltage (kVp) 16-row multidetector computed tomography (MDCT) combined with CM doses tailored to body weight, fixed injection duration adapted to scan time, automatic bolus tracking, and saline chaser. Material and Methods: Patients with estimated glomerular filtration rate (eGFR) <50 ml/min were scheduled to undergo 80-kVp MDCT using 200 mg I/kg, and those with eGFR =50 ml/min, 120-kVp MDCT with 320 mg I/kg. Both protocols used an 80-kg maximum dose weight and a fixed 15-s injection time. Pulmonary artery density and contrast-to-noise ratio were measured assuming 70 Hounsfield units (HU) for a fresh clot. CIN was defined as a plasma creatinine rise >44.2 mumol/l from baseline. Results: 89/148 patients (63/68 females) underwent 80-/120-kVp protocols, respectively, with 95% of the examinations being subjectively excellent or adequate. Mean values in the 80-/120-kVp cohorts regarding age were 82/65 years, body weight 66/78 kg, effective mAs 277/117, CM dose 13/23 g I, pulmonary artery density 359/345 HU, image noise (1 standard deviation) 24/21 HU, contrast-to-noise ratio 13/13, and dose-length product 173/258 mGycm. Only 1/65 and 2/119 patients in the 80- and 120-kVp cohorts, respectively, with negative CT and no anticoagulation suffered non-fatal thromboembolism during 3-month follow-up. No patient developed CIN. Conclusion: 80-kVp 16-row MDCT with optimization of injection parameters may be performed with preserved diagnostic quality, using markedly reduced CM

  6. Myelography in achondroplasia: value of a lateral C1-2 puncture and non-ionic, water-soluble contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Suss, R.A.; Udvarhelyi, G.B.; Wang, H.; Kumar, A.J.; Zinreich, S.J.; Rosenbaum, A.E.

    1983-10-01

    Because of technical difficulties and diagnostic limitations encountered with other myelographic techniques in patients with achondroplasia, the authors employed a lateral C1-2 puncture and non-ionic, water-soluble contrast medium in 18 achondroplastic patients with spinal compression (21 procedures). This technique proved most appropriate for identifying the upper limit of degenerative osteophytes causing exacerbation of congenital spinal stenosis, which is crucial in planning decompressive surgery. A potentially important additional finding was the presence of degenerative lower cervical spine disease in the majority of patients. There were no serious complications. The authors recommend this technique as safe and effective in achondroplastic patients with severe congenital spinal stenosis.

  7. Theoretical considerations in measurement of time discrepancies between input and myocardial time-signal intensity curves in estimates of regional myocardial perfusion with first-pass contrast-enhanced MRI.

    Science.gov (United States)

    Natsume, Takahiro; Ishida, Masaki; Kitagawa, Kakuya; Nagata, Motonori; Sakuma, Hajime; Ichihara, Takashi

    2015-11-01

    The purpose of this study was to develop a method to determine time discrepancies between input and myocardial time-signal intensity (TSI) curves for accurate estimation of myocardial perfusion with first-pass contrast-enhanced MRI. Estimation of myocardial perfusion with contrast-enhanced MRI using kinetic models requires faithful recording of contrast content in the blood and myocardium. Typically, the arterial input function (AIF) is obtained by setting a region of interest in the left ventricular cavity. However, there is a small delay between the AIF and the myocardial curves, and such time discrepancies can lead to errors in flow estimation using Patlak plot analysis. In this study, the time discrepancies between the arterial TSI curve and the myocardial tissue TSI curve were estimated based on the compartment model. In the early phase after the arrival of the contrast agent in the myocardium, the relationship between rate constant K1 and the concentrations of Gd-DTPA contrast agent in the myocardium and arterial blood (LV blood) can be described by the equation K1={dCmyo(tpeak)/dt}/Ca(tpeak), where Cmyo(t) and Ca(t) are the relative concentrations of Gd-DTPA contrast agent in the myocardium and in the LV blood, respectively, and tpeak is the time corresponding to the peak of Ca(t). In the ideal case, the time corresponding to the maximum upslope of Cmyo(t), tmax, is equal to tpeak. In practice, however, there is a small difference in the arrival times of the contrast agent into the LV and into the myocardium. This difference was estimated to correspond to the difference between tpeak and tmax. The magnitudes of such time discrepancies and the effectiveness of the correction for these time discrepancies were measured in 18 subjects who underwent myocardial perfusion MRI under rest and stress conditions. The effects of the time discrepancies could be corrected effectively in the myocardial perfusion estimates. Copyright © 2015 Elsevier Inc. All rights

  8. Biodegradable human serum albumin nanoparticles as contrast agents for the detection of hepatocellular carcinoma by magnetic resonance imaging.

    Science.gov (United States)

    Watcharin, Waralee; Schmithals, Christian; Pleli, Thomas; Köberle, Verena; Korkusuz, Hüdayi; Huebner, Frank; Zeuzem, Stefan; Korf, Hans W; Vogl, Thomas J; Rittmeyer, Claudia; Terfort, Andreas; Piiper, Albrecht; Gelperina, Svetlana; Kreuter, Jörg

    2014-05-01

    Tumor visualization by magnetic resonance imaging (MRI) and nanoparticle-based contrast agents may improve the imaging of solid tumors such as hepatocellular carcinoma (HCC). In particular, human serum albumin (HSA) nanoparticles appear to be a suitable carrier due to their safety and feasibility of functionalization. In the present study HSA nanoparticles were conjugated with gadolinium diethylenetriaminepentaacetic acid (Gd-DTPA) using carbodiimide chemistry. The nanoparticles had a uniform spherical shape and a diameter of 235±19nm. For better optical visualization in vitro and in vivo, the HSA-Gd nanoparticles were additionally labeled with rhodamine 123. As shown by confocal microscopy and flow cytometry analysis, the fluorescent nanoparticles were readily taken up by Huh-7 hepatocellular carcinoma cells. After 24h incubation in blood serum, less than 5% of the Gd(III) was released from the particles, which suggests that this nanoparticulate system may be stable in vivo and, therefore, may serve as potentially safe T1 MRI contrast agent for MRI of hepatocellular carcinoma. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Use of postmortem coronary computed tomography angiography with water-insoluble contrast medium to detect stenosis of the left anterior descending artery in a case of sudden death.

    Science.gov (United States)

    Takahashi, Yoichiro; Sano, Rie; Takahashi, Keiko; Kominato, Yoshihiko; Takei, Hiroyuki; Kobayashi, Susumu; Shimada, Takehiro; Tokue, Hiroyuki; Awata, Sachiko; Hirasawa, Satoshi

    2016-03-01

    A 40-year-old man was found dead on a sidewalk in an expressway parking area one hour after he had entered the area on a motorcycle. A medicolegal autopsy was performed to reveal the cause of this sudden and unexpected death. Postmortem coronary CT angiography after introduction of 5% gelatin-barium emulsion as a radiopaque contrast medium into the heart demonstrated a significant arterial luminal filling defect in the left anterior descending (LAD) coronary artery. Macroscopic and microscopic examinations revealed that a thrombus had become deposited on ruptured plaque within the LAD artery, and that a small amount of the contrast medium was present between the thrombus and the vessel endothelium. These histological findings were consistent with incomplete occlusion of the LAD artery in the 3D reconstructed image. The cause of death in this case was definitively determined to be ischemic heart disease. Postmortem angiography played a role in screening of a vascular lesion that was subsequently verified by histology to have been responsible for sudden and unexpected death. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. [Recurrence of drug eruption after renewed injection of iodinated contrast medium in patients with known allergic contraindications].

    Science.gov (United States)

    Amsler, E; Autegarden, J-E; Senet, P; Frances, C; Soria, A

    2016-12-01

    Iodinated contrast media (ICM) are used extensively by both radiologists and cardiologists. Injection of such products can induce immediate hypersensitivity reactions, some of which are IgE-mediated, and delayed hypersensitivity reaction with all types of drug eruptions being reported. Allergy tests, whether patch-tests or intradermal tests, are useful to confirm whether patients are allergic. At the end of these tests, depending on the reaction (chronology and clinical symptoms) and the results of the skin tests, patients are given an allergy card as well as a detailed certificate indicating the various ICM contraindicated and those allowed. We report herein three cases of patients experiencing a confirmed allergic eruption after injection of ICM, and whose recommendations and contraindication were not taken into consideration, leading to recurrence of eruption after renewed ICM injection. The three cases we report herein underscore the lack of knowledge concerning eruptions induced by ICM, particularly among radiologists. Better dissemination of information about the existence of such reactions appears necessary amongst the medical professionals concerned. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  11. Low concentration contrast medium for dual-source computed tomography coronary angiography by a combination of iterative reconstruction and low-tube-voltage technique: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Minwen, E-mail: zhengmw2007@163.com; Liu, Ying, E-mail: yingyinglyly@126.com; Wei, Mengqi, E-mail: weimengqi2008@163.com; Wu, Yongjie, E-mail: wu18291988526@163.com; Zhao, Hongliang, E-mail: zhaohl1980@163.com; Li, Jian, E-mail: xjyylj@yeah.net

    2014-02-15

    Objectives: To assess the impact of low-concentration contrast medium on vascular enhancement, image quality and radiation dose of coronary CT angiography (cCTA) by using a combination of iterative reconstruction (IR) and low-tube-voltage technique. Materials and methods: One hundred patients were prospectively randomized to two types of contrast medium and underwent prospective electrocardiogram-triggering cCTA (Definition Flash, Siemens Healthcare; collimation: 128 mm × 0.6 mm; tube current: 300 mA s). Fifty patients received Iopromide 370 were scanned using the conventional tube setting (100 kVp or 120 kVp if BMI ≥ 25 kg/m{sup 2}) and reconstructed with filtered back projection (FBP). Fifty patients received Iodixanol 270 were scanned using the low-tube-voltage (80 kVp or 100 kVp if BMI ≥ 25 kg/m{sup 2}) technique and reconstructed with IR. CT attenuation was measured in coronary artery and other anatomical regions. Noise, image quality and radiation dose were compared. Results: Compared with two Iopromide 370 subgroups, Iomeprol 270 subgroups showed no significant difference in CT attenuation (576.63 ± 95.50 vs. 569.51 ± 118.93 for BMI < 25 kg/m{sup 2}, p = 0.647 and 394.19 ± 68.09 vs. 383.72 ± 63.11 for BMI ≥ 25 kg/m{sup 2}, p = 0.212), noise (in various anatomical regions of interest) and image quality (3.5 vs. 4.0, p = 0.13), but significantly (0.41 ± 0.17 vs. 0.94 ± 0.45 for BMI < 25 kg/m{sup 2}, p < 0.001 and 1.14 ± 0.24 vs. 2.37 ± 0.69 for BMI ≥ 25 kg/m{sup 2}, p < 0.001) lower radiation dose, which reflects dose saving of 56.4% and 51.9%, respectively. Conclusions: Combined IR with low-tube-voltage technique, a low-concentration contrast medium of 270 mg I/ml can still maintain the contrast enhancement without impairing image quality, as well as significantly lower the radiation dose.

  12. Influence of cardiac insufficiency on acute renal impairment induced by contrast medium in patients with diabetes and renal dysfunction

    Directory of Open Access Journals (Sweden)

    Jing LI

    2015-10-01

    Full Text Available Objective To evaluate the influence of cardiac insufficiency on contrast-induced acute kidney injury (CIAKI after percutaneous coronary intervention (PCI in patients with diabetes mellitus (DM complicated with mild to moderate renal insufficiency (MMRI. Methods From Dec. 2008 to Oct. 2011, 2998 patients, with type 2 DM and concomitant chronic kidney diseases (CKD from 53 hospitals in China, were enrolled in the present study. Out of them, 2533 patients showed normal cardiac function (NYHA=1 and 465 patients suffered from cardiac insufficiency (NYHA>1. The demographic characteristics, preoperative renal function and postoperative incidence of CIAKI in the two groups were monitored. Results No significant difference was found between two groups (P>0.05 in preoperative baseline data (age, sex, high risk factors, etc.. The incidence of CIAKI was significantly higher in NYHA>1 group than in NYHA=1 group (4.7% vs2.8%, P=0.03. During a 30 day follow-up, the incidence of all-cause mortality was not significantly different between two groups (P>0.05. Multiple factors analysis found that rosuvastatin was the protective agent for CIAKI, and acute coronary syndrome, cardiac insufficiency, anemia and renal insufficiency were the risk factors for CIAKI. Conclusion For PCI, the risk of postoperative incidence of CIAKI is higher in patients with preoperative cardiac insufficiency than in those with normal cardiac function. The incidence of CIAKI may be reduced obviously by meticulous preoperative assessment of heart function in high-risk patients, giving effective treatment and performing PCI after cardiac function is improved. DOI: 10.11855/j.issn.0577-7402.2015.09.08

  13. Ultralow contrast medium doses at CT to diagnose pulmonary embolism in patients with moderate to severe renal impairment: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Kristiansson, Mattias; Nyman, Ulf [Lasarettet Trelleborg, University of Lund, Department of Diagnostic Radiology, Trelleborg (Sweden); Holmquist, Fredrik [Malmoe University Hospital, University of Lund, Department of Diagnostic Radiology, Malmoe (Sweden)

    2010-06-15

    To analyse 80-kVp 16-MDCT in patients with clinically suspected pulmonary embolism (PE) and diminished renal function after a reduction in dose of contrast medium (CM) from 200 to 150 mg I/kg. Fifty patients with suspected PE and glomerular filtration rate (GFR) less than 50 mL/min underwent 80-kVp 16-MDCT with 150 mg I/kg. Mean density/image noise (1 standard deviation) was measured in a region of interest in the left pulmonary artery (LPA) and a lower lobe segmental artery (LLSA), and the contrast-to-noise ratio (CNR) was calculated. The values of LPA and LLSA were averaged. Median values/2.5-97.5 percentiles were: age 84/67-96 years, weight 65/43-84 kg, GFR 36/21-45 mL/min, CM dose 9.6/6.4-12 g of iodine, PA density 353/164-495 HU and CNR 11/4.4-20. PE incidence was 16%, and 8% and 12% of the examinations were regarded suboptimal by observer 1 and 2, respectively. Density/CNR values were within ranges reported for common 120-kVp MDCT protocols. None of 32 patients with plasma-creatinine follow-up within 1 week experienced a rise of more than 44.2 {mu}mol/L and none of 50 patients had oliguria/anuria or dialysis. None of 40 patients with a negative CT/no anticoagulation had thromboembolism during follow-up. 80-kVp MDCT combined with individualised ultralow CM doses may provide satisfactory diagnostic quality, which should be to the benefit of patients at risk of contrast medium-induced nephropathy. (orig.)

  14. How good is the turbid medium-based approach for accounting for light partitioning in contrasted grass--legume intercropping systems?

    Science.gov (United States)

    Barillot, Romain; Louarn, Gaëtan; Escobar-Gutiérrez, Abraham J; Huynh, Pierre; Combes, Didier

    2011-10-01

    Most studies dealing with light partitioning in intercropping systems have used statistical models based on the turbid medium approach, thus assuming homogeneous canopies. However, these models could not be directly validated although spatial heterogeneities could arise in such canopies. The aim of the present study was to assess the ability of the turbid medium approach to accurately estimate light partitioning within grass-legume mixed canopies. Three contrasted mixtures of wheat-pea, tall fescue-alfalfa and tall fescue-clover were sown according to various patterns and densities. Three-dimensional plant mock-ups were derived from magnetic digitizations carried out at different stages of development. The benchmarks for light interception efficiency (LIE) estimates were provided by the combination of a light projective model and plant mock-ups, which also provided the inputs of a turbid medium model (SIRASCA), i.e. leaf area index and inclination. SIRASCA was set to gradually account for vertical heterogeneity of the foliage, i.e. the canopy was described as one, two or ten horizontal layers of leaves. Mixtures exhibited various and heterogeneous profiles of foliar distribution, leaf inclination and component species height. Nevertheless, most of the LIE was satisfactorily predicted by SIRASCA. Biased estimations were, however, observed for (1) grass species and (2) tall fescue-alfalfa mixtures grown at high density. Most of the discrepancies were due to vertical heterogeneities and were corrected by increasing the vertical description of canopies although, in practice, this would require time-consuming measurements. The turbid medium analogy could be successfully used in a wide range of canopies. However, a more detailed description of the canopy is required for mixtures exhibiting vertical stratifications and inter-/intra-species foliage overlapping. Architectural models remain a relevant tool for studying light partitioning in intercropping systems that exhibit

  15. Carbon dioxide is a cost-effective contrast medium to guide revascularization of TASC A and TASC B femoropopliteal occlusive disease.

    Science.gov (United States)

    de Almeida Mendes, Cynthia; de Arruda Martins, Alexandre; Teivelis, Marcelo Passos; Kuzniec, Sergio; Nishinari, Kenji; Krutman, Mariana; Halpern, Helio; Wolosker, Nelson

    2014-08-01

    Iodine contrast medium (ICM) is considered gold standard in endovascular revascularization procedures. However, nephrotoxicity and hypersensitivity to ICM are causes that limit its indiscriminate use. Carbon dioxide (CO2) contrast angiography has been used as an alternative in patients with formal contraindication to ICM. However, no studies to the present date have compared in a randomized and prospective way, outcomes of revascularization procedures performed with either ICM or CO2 in patients eligible for use of both contrasts. Between April 2012 and April 2013, 35 patients with peripheral arterial disease with arterial lesions classified as Trans-Atlantic Inter-Society Consensus A or B (identified on preoperative angio computed tomography scan) and adequate runoff underwent femoropopliteal revascularization by endovascular technique in a prospective, randomized, and controlled study. Patients were randomized into 2 groups: CO2 group and ICM group, according to the contrast media selected of the procedure. We evaluated the following outcomes in both groups: feasibility of the procedures, complications, surgical outcomes (ankle-brachial index [ABI]), glomerular filtration rate using the Cockcroft-Gault formula, relationship between the volume of injected iodine and postoperative creatinine clearance, quality of the angiographic images obtained with CO2, costs of the endovascular materials, and finally, cost of contrast agents. We were able to perform the proposed procedures in all patients treated in this series (ICM group and CO2). There were no CO2-related complications. No procedures required conversion to open surgery. Clinical results were satisfactory, with regression of ischemia and increased levels of ABI in both groups. Variations in creatinine clearance levels showed a numerical increase in the CO2 group and a decrease in ICM group, however, with no statistically significant difference between the delta clearance in each group. All CO2 arteriograms of

  16. An albumin-based gold nanocomposites as potential dual mode CT/MRI contrast agent

    Science.gov (United States)

    Zhao, Wenjing; Chen, Lina; Wang, Zhiming; Huang, Yuankui; Jia, Nengqin

    2018-02-01

    In pursuit of the biological detection applications, recent years have witnessed the prosperity of novel multi-modal nanoprobes. In this study, biocompatible bovine serum albumin (BSA)-coated gold nanoparticles (Au NPs) containing Gd (III) as the contrast agent for both X-ray CT and T1-weighted MR imaging is reported. Firstly, the Au NPs with BSA coating (Au@BSA) was prepared through a moderate one-pot reduction route in the presence of hydrazine hydrate as reducer. Sequentially, the BSA coating enables modification of diethylenetriaminepentaacetic acid (DTPA) as well as targeting reagent hyaluronic acid (HA), and further chelation of Gd (III) ions led to the formation of biomimetic nanoagent HA-targeted Gd-Au NPs (HA-targeted Au@BSA-Gd-DTPA). Several techniques were used to thoroughly characterize the formed HA-targeted Gd-Au NPs. As expected, the as-prepared nanoagent with mean diameter of 13.82 nm exhibits not only good colloid stablility and water dispersibility, but also satisfying low cytotoxicity and hemocompatibility in the tested concentration range. Additionally, for the CT phantoms, the obtained nanocomplex shows an improved contrast in CT scanning than that of Au@BSA as well as small molecule iodine-based CT contrast agents such as iopromide. Meanwhile, for the T1-weighted MRI images, there is a linear increase of contrast with concentration of Gd for the two cases of HA-targeted Gd-Au NPs and Magnevist. Strikingly, the nanoagent we explored displays a relatively higher r1 relaxivity than that of commercial MR contrast agents. Therefore, this newly constructed nanoagent could be used as contrast agents for synergistically enhanced X-ray CT and MR phantoms, holding promising potential for future biomedical applications.

  17. Visualization of endolymphatic hydrops in meniere's disease after single-dose intravenous gadolinium-based contrast medium. Timing of optimal enhancement

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Yamazaki, Masahiro; Kawai, Hisashi; Bokura, Kiminori; Sone, Michihiko; Nakashima, Tsutomu

    2012-01-01

    Visualization of endolymphatic hydrops (EH) in patients with Meniere's disease (MD) is now possible by heavily T 2 -weighted 3-dimensional fluid-attenuated inversion recovery (h T 2 W-3D-FLAIR) obtained 4 hours after intravenous (IV) administration of single dose gadolinium-based contrast medium (GBCM). Although maximum enhancement has been reported 4 hours after contrast administration in healthy volunteers, the timing of optimal enhancement in patients with MD is not reported. We investigated if that optimal timing is earlier or later than 4 hours. We evaluated 10 consecutive patients with suspected MD whom we randomly divided into 2 groups. We obtained h T 2 W-3D-FLAIR before GBCM administration and 10 min, 3.5 hours, and 4 hours after GBCM administration in Group A and before and 10 min, 4 hours, and 4.5 hours after GBCM administration in Group B. We compared signal intensity ratio (SIR) values of the perilymph and pons between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B and evaluated grades of EH at 3.5 and 4 hours in Group A and at 4 and 4.5 hours in Group B. SIR values did not differ significantly between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. However, SIR values at 4 hours were significantly higher in Group A than Group B. Grades of EH agreed between 3.5 and 4 hours in Group A and between 4 and 4.5 hours in Group B. The optimal timing of contrast enhancement in patients with suspected MD remains unclear, but evaluation of EH may be possible from 3.5 to 4.5 hours after contrast administration. (author)

  18. Appearance of high signal intensity and gadolinium-DTPA contrast enhancement in hypertrophied myocardium by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko; Yamada, Naoaki; Nagata, Seiki (National Cardiovascular Center, Suita, Osaka (Japan))

    1989-11-01

    This study was undertaken to examine the potential role of magnetic resonance imaging (MRI) for evaluating myocardial tissue characterization in hypertrophic cardiomyopathy (HCM). ECG-gated MRI images were acquired in 32 HCM patients and 30 patients with hypertensive heart disease (HHD), using a 1.5 T superconducting magnet system. The thickened areas were depicted as high signal intensities in the septum of 12 HCM patients (38%) and the endocardium of 5 HHD patients (17%). Echocardiography revealed that MRI appearance of high signal intensity was associated with more thickened myocardial wall. For evaluable 16 patients receiving i.v. injection of Gd-DTPA in a dose of 0.1 mM/kg, enhancement effects were observed in 10 patients (63%). High signal intensity appearing in the hypertrophied myocardium, as well as contrast enhancement, may not be characteristic of HCM, but reflect the likelihood of myocardial degeneration associated with the hypertrophied myocardium. Although MRI may not be capable of differentiating tissue characterization in HCM from that in HHD, it may provide different information about tissue characterization in the hypertrophied myocardium from that obtained by other techniques. (N.K.).

  19. MR-guided percutaneous nephrostomy of the contrast-enhanced, nondilated upper urinary tract: initial experimental results

    International Nuclear Information System (INIS)

    Nolte-Ernsting, C.C.A.; Buecker, A.; Neuerburg, J.M.; Adam, G.B.; Guenther, R.W.; Hunter, D.W.

    1998-01-01

    Purpose: To evaluate technique and practicability of MR-guided percutaneous nephrostomy (MRPCN) in an animal model. Methods: In three domestic pigs, a unilateral percutaneous nephrostomy tube was placed into the nondilated collecting system using exclusively MR-guidance with a standard 1.5 T scanner. The urinary tract was visualized by intravenous injection of Gd-DTPA and low-dose furosemide. The entire interventional procedure was controlled using a T 1 -weighted 'dual stack' 2D TFE sequence in two orthogonal planes. Results: In all three animals, the puncture needle was safely directed into the nondilated target calyx. Even slight deviations of the needle from the optimal path were readily detected on both MR image planes which enabled immediate correction. This technique successfully achieved a 'first attempt' puncture of the targeted calyx in each animal. Over a nitinol guidewire a 5 F catheter was placed into the renal pelvis. Its dysprosium labelled tip was acurately delineated on contrast-enhanced MR images. Conclusions: Percutaneous nephrostomy under MR guidance is a very feasible technique for puncturing the nondilated pelvicalyceal system. This procedure offers some advantages over the current standard modalities. (orig.) [de

  20. Significance of Gd-DTPA enhanced MRI in lumbar disc herniation

    Energy Technology Data Exchange (ETDEWEB)

    Hijikuro, Taiji; Nakai, Osamu; Shindo, Shigeo; Mizuno, Kouichi; Otani, Kazuyuki; Yamaura, Isakichi [Kudanzaka Hospital, Tokyo (Japan)

    2001-04-01

    To know the significance of enhanced MRI images for prediction of prognosis of lumbar disc herniation, the images of 202 patients were retrospectively compared in relation with their findings at surgery, histo-pathological ones, clinical process and morphology. After intravenous injection of soluble Gd, T1 and T2-weighted imaging had been done with Yokogawa SignaConta (0.5T). Surgery was conducted on 99 patients and conservative therapy, on 103. Patients were classified into 3 groups: those giving enhanced effect in and behind the herniation, and without the effect. The enhancement was observed in 62%. Bad prognosis was seen in 37% of patients without the enhancing effect and the enhanced MRI was concluded to be useful for prediction of prognosis. (K.H.)

  1. Recurrent medulloblastoma: Frequency of tumor enhancement on Gd-DTPA MR imaging

    International Nuclear Information System (INIS)

    Rollins, N.; Mendelsohn, D.; Mulne, A.; Barton, R.; Diehl, J.; Reyes, N.; Sklar, F.

    1990-01-01

    Thirty-two children with medulloblastoma were evaluated postoperatively with conventional and gadolinium-enhanced MR imaging. Eleven patients had abnormal cranial MR studies; nine of these had recurrent tumor. In six patients recurrent tumor enhanced with Gd, while in the other three patients recurrent tumor did not enhance. The remaining two patients had areas of abnormal Gd enhancement that were caused by radiation-induced breakdown of the blood-brain barrier rather than by recurrent tumor. This study shows that not all recurrent medulloblastoma enhances and that the absence of Gd enhancement does not necessarily indicate the absence of recurrent tumor

  2. High-pitch coronary CT angiography at 70 kVp adopting a protocol of low injection speed and low volume of contrast medium

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Ruiqi; Liu, Xiao Fei; Zhao, Yu; Zhang, Liang [Dept. of Radiology, The First Affiliated Hospital of China Medical University, Shenyang (China); Tong, Jia Jie [Dept. of Radiology, Hebei General Hospital, Shijiazhuang(China)

    2017-09-15

    To evaluate the feasibility and image quality (IQ) of prospectively high-pitch coronary CT angiography (CCTA) with low contrast medium injection rate at 70 kVp. One hundred and four patients with suspected coronary artery disease (body mass index < 26 kg/m{sup 2}, sinus rhythm and heart rate < 70 beats/min) were prospectively enrolled and randomly divided into two groups. In group A and group B, 28 mL and 40 mL of 370 mgI/mL iodinated contrast media was administrated at a flow rate of 3.5 and 5 mL/s, respectively. CT values, noise, signal-to-noise ratio, contrast-to-noise ratio (CNR) of the proximal segments of coronary arteries and subjective IQ were evaluated. The CT values and noise in group A were significantly lower than those in group B (434–485 Hounsfield units [HU] vs. 772–851 HU, all p < 0.001; 17.8–22.3 vs. 23.3–26.4, all p < 0.005). The CNRs of the right coronary artery and left main artery showed no statistical difference between the two groups (42.1 ± 13.8 vs. 36.8 ± 16.0, p = 0.074; 38.7 ± 10.6 vs. 38.1 ± 17.0, p = 0.819). No statistical difference was observed between the two groups in IQ scores (3.04 ± 0.75 vs. 3.0 ± 0.79, p = 0.526) and diagnostic ratio (96.1% [50/52] vs. 94.2% [49/52], p = 0.647). Prospective high-pitch CCTA at 70 kVp with 28 mL of contrast media and injection rate of 3.5 mL/s could provide diagnostic IQ for normal-weight patients with heart rate of < 70 beats/min.

  3. MRI in Crohns disease after transduodenal contrast administration using negative oral MRI constrast media

    International Nuclear Information System (INIS)

    Holzknecht, N.; Helmberger, T.; Herrmann, K.; Reiser, M.; Ochsenkuehn, T.; Goeke, B.

    2003-01-01

    To compare the efficacy and quality of conventional and MR enteroclysis with different filling methods regarding the assessment of extension and extraluminal manifestations in Crohn's disease.Material and Methods 190 patients with known Crohn's disease were studied following small bowel enteroclysis, after oral administration or direct transduodenal filling in the MRI-department.T1- and T2-weighted breathhold MRI-scans w/o spectral fat suppression w/o i.v.Gd-DTPA were applied using negative oral superparamagnetic contrast media. Typical findings were marked bowel wall thickening with laminated wall contrast enhancement.In 135 patients 98,2% of affected bowel segments, 97,5% of stenoses and all 16 fistulas were detected,when conventional enteroclysis was employed as standard of reference.Additional important extraluminal findings such as ileoileal (n = 18), ileosigmoidal adhesions (n = 12), extraluminal abscesses (n = 35) and pseudotumors (n = 8) were visualized in 73/135 patients. Concerning the distension of jejunum and ileum, oral filling was rated significantly inferior to transduodenal filling in all small bowel segments,whereas filling in the MRI-unit was rated superior to fluoroscopic, mostly due to a mean transport time of 20 min to the MRI-unit. No clinically important findings of enteroclysis were missed when using MRI. Therefore, in patients with Crohn's disease, conventional enteroclysis can be replaced by MRI.For optimal bowel distension oral contrast administration is inferior to transduodenal filling, if a larger time delay between filling and the MRI-scan can be avoided. (orig.) [de

  4. Concentration of gadolinium-diethylene triamine pentaacetic acid in human kidney

    International Nuclear Information System (INIS)

    Takeda, Masayuki; Katayama, Yasushi; Tsutsui, Toshiki; Komeyama, Takeshi; Mizusawa, Takaki; Tanikawa, Toshiki; Sato, Shotaro

    1993-01-01

    Although gadolinium diethylene triamine pentaacetic acid (Gd-DTPA) has been used as a contrast material in magnetic resonance imaging, it is known that contrast enhancement effect disappears if the concentration of Gd-DTPA increases beyond some levels. In this study, to evaluate the proper pulse sequences for dynamic magnetic resonance imaging (MRI) in the human kidney, the concentration of Gd-DTPA was quantitatively measured by inductively coupled plasma (ICP) emission spectrometry in human biological samples after administration of Gd-DTPA, and the signal intensity of MRI is the solution of several concentrations of Gd-DTPA was measured. In using a low magnetic field apparatus, signal intensity linearly correlated with the concentration of Gd-DTPA between 0 and 2.0 μmol/g under saturation recovery sequences (flip angle was 60deg or 90deg). Using a high magnetic field apparatus, signal intensity linearly correlated with the concentration of Gd-DTPA between 0 and 2.0 or 3.0 μmol/g under spin echo or gradient-echo sequences. Gd-DTPA concentration of the renal cortex ranged from 0.132 to 0.152 μmol/g tissue at 5 min after intravenous injection of Gd-DTPA 0.05 mmol/kg body weight in 7 patients with adrenal tumor or renal cell cancer, and 1 patient with both urinary bladder cancer and prostatic cancer. Seven of them showed normal renal function and the other had renal insufficiency (GFR 25 ml/min/1.48 m 2 ). Gd-DTPA concentrations of renal medulla and renal cell cancer tissue were 0.123 and 0.108 μmol/g tissue, respectively, at 5 min after intravenous injection of Gd-DTPA 0.05 mmol/kg body weight. These results suggest that the signal intensity of renal cortex, renal medulla, and renal cell cancer tissue may linearly correlate with Gd-DTPA concentration of tissues at 5 min after intravenous injection of Gd-DTPA 0.5 mmol/kg body weight. (author)

  5. Assessment of arterial tumor vascularity in small hepatocellular carcinoma. Comparison between color Doppler ultrasonography and radiographic imagings with contrast medium: dynamic CT, angiography, and CT hepatic arteriography

    International Nuclear Information System (INIS)

    Furuse, Junji; Maru, Yasushi; Yoshino, Masahiro; Mera, Kiyomi; Sumi, Hajime; Sekiguchi, Ryuzo; Satake, Mitsuo; Hasebe, Takahiro; Ochiai, Atsushi

    2000-01-01

    Hepatocellular carcinoma (HCC) is characterized by tumor vascularization from the hepatic artery. The objective of our work was to compare color Doppler ultrasonography (CDU), including power Doppler ultrasonography (PDU) with radiographic imagings with contrast medium in regard to the detection of the arterial tumor vascularity of small hepatocellular carcinomas (HCC). We examined 42 small HCC lesions 2 cm or less in diameter in 37 patients for arterial tumor vascularity by conventional CDU, PDU, dynamic computed tomography (dCT), digital subtraction angiography (DSA), and CT hepatic arteriography (CTA). Color images were detected in 25 (59.5%) and 28 (66.7%) of the 42 lesions with conventional CDU and PDU, respectively, and tumor vascularity was detected in 26 (61.9%) by dCT, 23 (54.8%) by DSA, and 29 (69.0%) by CTA. Tumor vascularity could be detected in 51.9% by PDU and CTA, more than by conventional CDU, dCT, and DSA (44.4, 44.4, and 33.3%, respectively) in well-differentiated HCC, whereas the detection rates by these techniques were almost equal (86.7% by CDU, 93.3% by PDU, dCT, and DSA, 100% by CTA, respectively) in moderately and poorly differentiated HCC. PDU is superior to CDU, dCT and DSA and equal to CTA for the detection of tumor vascularity in small HCC, particularly in well-differentiated HCC

  6. Comparative safety of gadodiamide, dimeglumine gadopentetate and meglumine gadoterate in MRI of the central nervous system

    International Nuclear Information System (INIS)

    Chanalet, S.; Bruneton, J.N.; Masson, B.; Boyer, L.; Laffont, J.

    1995-01-01

    The development of new non-ionic magnetic resonance (MR) contrast media as gadodiamide injection increased the choice of paramagnetic contrast agents available in MR of the central nervous system (CNS). The purpose of our paper was to compare at the dose of 0.1 mmol/kg b.w. the safety of gadodiamide (Gd-DTPA-BMA) to gadopentetate dimeglumine (Gd-DTPA) and to gadoterate meglumine (Gd-DOTA) in two multi centric double-blind studies. A total of 551 patients were enrolled with 143 patients in the Gd-DTPA group, 132 patients in the Gd-DOTA group and 276 patients in the Gd-DTPA-BMA group. Safety was assessed by recording the adverse events up to 24 hours after the injection. One or more adverse events were recorded in 14% of the Gd-DTPA patients, in 15.1% of the Gd-DOTA patients and in 11.6% of the Gd-DTPA-BMA patients. These reactions were related to the contrast media in 9.1%, 13.6% and 8.7% of the cases respectively. Their intensity was defined as mild in 8.4% of the patients in the Gd-DTPA group, in 13.6% of the patients in the Gd-DOTA group and in 8.3% of the patients in the Gd-DTPA-BMA group. No severe reaction or death were recorded. An injection-site reaction (heat, coldness, pain) has been observed in 43% of the cases although an adverse event other than local reactions (headache, dizziness, nausea) has been noticed in 57% of the cases. No significant statistical difference was observed between the groups. Gadodiamide is a safe and effective contrast agent in MRI of the CNS in comparison with Gd-DTPA and Gd-DOTA currently in routine use

  7. Pharmacokinetics of Chiral Dendrimer-Triamine-Coordinated Gd-MRI Contrast Agents Evaluated by in Vivo MRI and Estimated by in Vitro QCM.

    Science.gov (United States)

    Miyake, Yuka; Ishikawa, Syungo; Kimura, Yu; Son, Aoi; Imai, Hirohiko; Matsuda, Tetsuya; Yamada, Hisatsugu; Toshimitsu, Akio; Kondo, Teruyuki

    2015-12-18

    Recently, we developed novel chiral dendrimer-triamine-coordinated Gd-MRI contrast agents (Gd-MRI CAs), which showed longitudinal relaxivity (r₁) values about four times higher than that of clinically used Gd-DTPA (Magnevist(®), Bayer). In our continuing study of pharmacokinetic differences derived from both the chirality and generation of Gd-MRI CAs, we found that the ability of chiral dendrimer Gd-MRI CAs to circulate within the body can be directly evaluated by in vitro MRI (7 T). In this study, the association constants (K(a)) of chiral dendrimer Gd-MRI CAs to bovine serum albumin (BSA), measured and calculated with a quartz crystal microbalance (QCM) in vitro, were found to be an extremely easy means for evaluating the body-circulation ability of chiral dendrimer Gd-MRI CAs. The K(a) values of S-isomeric dendrimer Gd-MRI CAs were generally greater than those of R-isomeric dendrimer Gd-MRI CAs, which is consistent with the results of our previous MRI study in vivo.

  8. Pharmacokinetics of Chiral Dendrimer-Triamine-Coordinated Gd-MRI Contrast Agents Evaluated by in Vivo MRI and Estimated by in Vitro QCM

    Directory of Open Access Journals (Sweden)

    Yuka Miyake

    2015-12-01

    Full Text Available Recently, we developed novel chiral dendrimer-triamine-coordinated Gd-MRI contrast agents (Gd-MRI CAs, which showed longitudinal relaxivity (r1 values about four times higher than that of clinically used Gd-DTPA (Magnevist®, Bayer. In our continuing study of pharmacokinetic differences derived from both the chirality and generation of Gd-MRI CAs, we found that the ability of chiral dendrimer Gd-MRI CAs to circulate within the body can be directly evaluated by in vitro MRI (7 T. In this study, the association constants (Ka of chiral dendrimer Gd-MRI CAs to bovine serum albumin (BSA, measured and calculated with a quartz crystal microbalance (QCM in vitro, were found to be an extremely easy means for evaluating the body-circulation ability of chiral dendrimer Gd-MRI CAs. The Ka values of S-isomeric dendrimer Gd-MRI CAs were generally greater than those of R-isomeric dendrimer Gd-MRI CAs, which is consistent with the results of our previous MRI study in vivo.

  9. A simulation study of enhancement duration in three-dimensional contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Ohkubo, Masaki; Ohgoshi, Yukio; Inoue, Tomoko; Naito, Kenichi; Suzuki, Kiyotaka

    2001-01-01

    In our study on three-dimensional (3D) contrast-enhanced MR angiography we performed a computer simulation to investigate quantitative vessel visibility. In the simulation, we evaluated the relative loss of signal intensity in a vessel due to shortened duration of contrast-enhancement. The mid-point of enhancement-duration was assumed to be at the point in which the data in the center of k-space (k y axis) was acquired. Signal intensity of a vessel decreased as the enhancement-duration was shortened and the diameter of the vessel was decreased. When the duration was shortened 40%, the signal intensity of a vessel in which the diameter was more than 2 pixels was preserved by approximately 70% or more. This suggests that the vessel visibility is high. When the duration was shortened 20%, the signal intensity of a vessel in which the diameter was less than 2 pixels decreased to less than approximately 40% or less. The simulation was confirmed by using 3D MR angiography with a tube phantom filled with Gd-DTPA to simulate a vessel model. At anytime during data acquisition, we could set the phantom on the region being scanned or take it out by using the ''pause'' function of the MR scanner. This made it possible to change the enhancement-duration to match the simulation. Results of the phantom study were comparable to those of the simulation, suggesting that the simulation was valid. Our results and simple techniques for both the simulation and the phantom study using the ''pause'' function, were considered useful in the study of 3D MR angiography. (author)

  10. MR-guided percutaneous nephrostomy of the contrast-enhanced, nondilated upper urinary tract: initial experimental results; MR-tomographisch gesteuerte perkutane Nephrostomie des kontrastangehobenen, nicht dilatierten oberen Harntraktes: Erste experimentelle Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Nolte-Ernsting, C.C.A.; Buecker, A.; Neuerburg, J.M.; Adam, G.B.; Guenther, R.W. [RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik; Hunter, D.W. [Minnesota Univ. (United States). Dept. of Radiology

    1998-06-01

    Purpose: To evaluate technique and practicability of MR-guided percutaneous nephrostomy (MRPCN) in an animal model. Methods: In three domestic pigs, a unilateral percutaneous nephrostomy tube was placed into the nondilated collecting system using exclusively MR-guidance with a standard 1.5 T scanner. The urinary tract was visualized by intravenous injection of Gd-DTPA and low-dose furosemide. The entire interventional procedure was controlled using a T{sub 1}-weighted `dual stack` 2D TFE sequence in two orthogonal planes. Results: In all three animals, the puncture needle was safely directed into the nondilated target calyx. Even slight deviations of the needle from the optimal path were readily detected on both MR image planes which enabled immediate correction. This technique successfully achieved a `first attempt` puncture of the targeted calyx in each animal. Over a nitinol guidewire a 5 F catheter was placed into the renal pelvis. Its dysprosium labelled tip was acurately delineated on contrast-enhanced MR images. Conclusions: Percutaneous nephrostomy under MR guidance is a very feasible technique for puncturing the nondilated pelvicalyceal system. This procedure offers some advantages over the current standard modalities. (orig.) [Deutsch] Ziel: Ueberpruefung von Technik und Durchfuehrbarkeit einer MR-tomographisch gesteuerten perkutanen Nephrostomie (MR-PNS) im Tierexperiment. Methoden: Bei drei Hausschweinen wurde eine einseitige perkutane Nephrostomie des nicht dilatierten Hohlraumsystems ausschliesslich unter MR-tomographischer Kontrolle mit einem geschlossenen 1,5-T-System durchgefuehrt. Die Kontrastierung des oberen Harntraktes erfolgte durch eine intravenoese Injektion von Gd-DTPA und niedrigdosiertem Furosemid. Die einzelnen Interventionsschritte wurden mit einem T{sub 1}-gewichteten `Doppel-Schichtstapel` 2D-TFE Sequenz in zwei orthogonalen Schichtebenen kontrolliert. Ergebnisse: Bei allen drei Versuchstieren liess sich die Punktionsnadel unter MR

  11. Sequential gadolinium-DTPA enhanced MRI studies in neuro-Behcet's disease

    International Nuclear Information System (INIS)

    Kazui, S.; Naritomi, H.; Ogawa, M.; Sawada, T.; Imakita, S.; Yamada, N.

    1991-01-01

    Sequential gadolinium-DTPA (Gd-DTPA) enhanced MR images were obtained before and after steroid therapy in a case of neuro-Behcet's disease. Multiple scattered lesions, which could not be detected on pre- and post-contrast CT, were demonstrated mainly in the white matter of the pons and/or the cerebrum with both T1- and T2-weighted images. Some of these lesions, however, were not enhanced at all by infusion of Gd-DTPA. The Gd-DTPA infusion study demonstrated marked enhancement in the white matter of the pons and cerebrum. Some lesions not seen with T2-weighted images were also strongly enhanced by Gd-DTPA infusion at the acute stage. After steroid therapy, the symptoms and abnormal laboratory findings were resolved. The pontine and cerebral lesions on plain MR images remained unchanged even after resolution of the symptoms, suggesting that they were inactive old foci. On the other hand, the lesions detected in the enhancement study before steroid therapy disappeared with the repeat Gd-DTPA enhanced MR images which were performed after resolution of the symptoms. Some active inflammatory lesions in neuro-Behcet's disease may be demonstrated only on Gd-DTPA enhanced MR images. Gd-DTPA enhanced MR imaging appears to be potentially useful for detecting active inflammatory lesions in neuro-Behcet's disease and for evaluating the efficacy of treatment. (orig.)

  12. Experimental autoimmune encephalomyelitis (EAE): lesion visualization on a 3 tesla Clinical whole-body system after intraperitoneal contrast injection

    Energy Technology Data Exchange (ETDEWEB)

    Heckl, S.; Naegele, T.; Klose, U. [Dept. of Neuroradiology, Medical School, Univ. of Tuebingen (Germany); Herrmann, M.; Gaertner, S.; Weissert, R. [Dept. of Neurology, Medical School, Univ. of Tuebingen (Germany); Schick, F. [Dept. of Radiology, Medical School, Univ. of Tuebingen (Germany); Kueker, W. [Dept. of Neuroradiology, Medical School, Univ. of Tuebingen (Germany); Dept. of Neuroradiology, Radcliffe Infirmary, Oxford, England (United Kingdom)

    2004-11-01

    Purpose: To investigate the intravital visibility of CNS lesions in rats with experimental autoimmune encephalomyelitis (EAE), the animal correlate of multiple sclerosis, using a 3-Tesla (T) wholebody MR system. Materials and Methods: Three healthy Dark Agouti (DA) rats and 16 DA rats with clinical signs of EAE were examined on a 3T whole body-system using a normal wrist coil. In total, 25 examinations were preformed using T2- and T1-weighted images in transverse and sagittal orientation with a slice thickness of 2 mm or 1 mm (voxel size up to 0.2 x 0.2 x 1 mm). Sedation was achieved by intraperitoneal injection of ketamine and xylazine. In addition, T1-weighted images were obtained after the instillation of 1.0 ml of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) (0.5 mmol/ml) into the peritoneal cavity. Results: T2- and T1-weighted images of the brain and spinal cord with high spatial and contrast resolution could be obtained in all animals. The anatomical details of the olfactory bulb glomeruli, cerebellum foliae, ventricles and corpus callosum were clearly visible. The EAE lesions presented as hyperintense area in T2-weighted images and could be demonstrated in all clinically affected animals by MRI and histologically verified. In total, the 16 affected rats had 28 cerebral and 2 spinal cord lesions (range 1 to 4, median 2). Contrast enhancement was noted in 12 animals and ranked as severe in ten and moderate in two cases. No adverse effects were noted due to sedation or intraperitoneal contrast injection. Conclusions: The intravital demonstration of cerebral and spinal cord EAE lesions in rats is possible on a 3T whole-body MR scanner using a normal wrist coil. Intraperitoneal injection of ketamine/xylazine and contrast agent is an easy, safe and effective procedure in rats. (orig.)

  13. Body surface area adapted iopromide 300 mg/ml versus 370 mg/ml contrast medium injection protocol: Influence on quantitative and clinical assessment in combined PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Verburg, Frederik A., E-mail: fverburg@ukaachen.de [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Apitzsch, Jonas [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Lensing, Carina [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Kuhl, Christiane K. [RWTH Aachen University Hospital, Department of Diagnostic and Interventional Radiology, Pauwelsstraße 30, 52074 Aachen (Germany); Pietsch, Hubertus [Bayer Pharma AG, Müllerstrasse 178, 13353 Berlin (Germany); Mottaghy, Felix M. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany); Maastricht University Medical Center, Department of Nuclear Medicine, P. Debyelaan 25, 6229 HX Maastricht (Netherlands); Behrendt, Florian F. [RWTH Aachen University Hospital, Department of Nuclear Medicine, Pauwelsstraße 30, 52074 Aachen (Germany)

    2013-12-01

    Purpose: To investigate the quantitative and qualitative differences between combined positron emission tomography and computed X-ray tomography (PET/CT) enhanced with contrast medium with either an iodine concentration 300 mg/ml or 370 mg/ml. Materials and methods: 120 consecutive patients scheduled for F-18-Fluorodeoxyglucose (FDG) PET/CT were included. The first (second) 60 patients received contrast medium with 300 (370) mg iodine/ml. Intravenous injection protocols were adapted for an identical iodine delivery rate (1.3 mg/s) and body surface area (BSA) adapted iodine dose (22.26 g I/m{sup 2}). Maximum and mean standardized uptake values (SUV{sub max}; SUV{sub mean}) and contrast enhancement (HU) were determined in the ascending aorta, the abdominal aorta, the inferior vena cava, the portal vein, the liver and the right kidney in the venous contrast medium phase. PET data were evaluated visually for the presence of malignancy and image quality. Results: Both media caused significantly higher values for HU, SUV{sub mean} and SUV{sub max} for the enhanced PET/CT than the non-enhanced one (all p < 0.01). There were no significant differences in the degree of increase of HU, SUV{sub mean} and SUV{sub max} between the two contrast media at any anatomic site (all p > 0.05). Visual evaluation of lesions showed no differences between contrast and non-contrast PET/CT or between the two different contrast media (p = 0.77). Conclusion: When using a constant iodine delivery rate and total iodine dose in a BSA adapted injection protocol, there are no quantitative or qualitative differences in either CT or PET between contrast media with an iodine concentration of 300 mg/ml and 370 mg/ml, respectively.

  14. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic...... measures used to reduce the incidence of CIN, and the management of patients receiving metformin. Key Points • Definition, risk factors and prevention of contrast medium induced nephropathy are reviewed. • CIN risk is lower with intravenous than intra-arterial iodinated contrast medium. • eGFR of 45 ml....../min/1.73 m (2) is CIN risk threshold for intravenous contrast medium. • Hydration with either saline or sodium bicarbonate reduces CIN incidence. • Patients with eGFR = 60 ml/min/1.73 m (2) receiving contrast medium can continue metformin normally....

  15. Perforations during contrast enema

    International Nuclear Information System (INIS)

    Vogel, H.; Steinkamp, U.; Grabbe, E.; Allgemeines Krankenhaus Ochsenzoll, Hamburg

    1983-01-01

    During contrast enema, perforation into the retroperitoneal space can be differentiated from perforation into the peritoneum and perforation into the intestinal wall associated with formation of barium granulomas or submucosal spreading of the contrast medium. Other special forms are perforation with contrast medium embolism of diverticula; of the processus vermiformis; penetration of contrast medium into fistulous systems and from the operated areas. Risk factors are: balloon catheter, intestinal tubes with a hard tip, preternatural anus, excessive enema pressure, contrast medium additions, preceding manipulations, intestinal diseases, advanced age and delegation of manipulations to assistants and unskilled staff. Children are particularly at risk. (orig.) [de

  16. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me....../min/1.73 m (2) is CIN risk threshold for intravenous contrast medium. • Hydration with either saline or sodium bicarbonate reduces CIN incidence. • Patients with eGFR = 60 ml/min/1.73 m (2) receiving contrast medium can continue metformin normally....

  17. Contrast induced nephropathy

    DEFF Research Database (Denmark)

    Stacul, Fulvio; van der Molen, Aart J; Reimer, Peter

    2011-01-01

    PURPOSE: The Contrast Media Safety Committee (CMSC) of the European Society of Urogenital Radiology (ESUR) has updated its 1999 guidelines on contrast medium-induced nephropathy (CIN). AREAS COVERED: Topics reviewed include the definition of CIN, the choice of contrast medium, the prophylactic me....../min/1.73 m (2) is CIN risk threshold for intravenous contrast medium. • Hydration with either saline or sodium bicarbonate reduces CIN incidence. • Patients with eGFR ≥ 60 ml/min/1.73 m (2) receiving contrast medium can continue metformin normally....

  18. Body surface area adapted iopromide 300 mg/ml versus 370 mg/ml contrast medium injection protocol: influence on quantitative and clinical assessment in combined PET/CT.

    Science.gov (United States)

    Verburg, Frederik A; Apitzsch, Jonas; Lensing, Carina; Kuhl, Christiane K; Pietsch, Hubertus; Mottaghy, Felix M; Behrendt, Florian F

    2013-12-01

    To investigate the quantitative and qualitative differences between combined positron emission tomography and computed X-ray tomography (PET/CT) enhanced with contrast medium with either an iodine concentration 300 mg/ml or 370 mg/ml. 120 consecutive patients scheduled for F-18-Fluorodeoxyglucose (FDG) PET/CT were included. The first (second) 60 patients received contrast medium with 300 (370) mg iodine/ml. Intravenous injection protocols were adapted for an identical iodine delivery rate (1.3mg/s) and body surface area (BSA) adapted iodine dose (22.26 gI/m(2)). Maximum and mean standardized uptake values (SUV(max); SUV(mean)) and contrast enhancement (HU) were determined in the ascending aorta, the abdominal aorta, the inferior vena cava, the portal vein, the liver and the right kidney in the venous contrast medium phase. PET data were evaluated visually for the presence of malignancy and image quality. Both media caused significantly higher values for HU, SUV(mean) and SUV(max) for the enhanced PET/CT than the non-enhanced one (all pmedia at any anatomic site (all p>0.05). Visual evaluation of lesions showed no differences between contrast and non-contrast PET/CT or between the two different contrast media (p=0.77). When using a constant iodine delivery rate and total iodine dose in a BSA adapted injection protocol, there are no quantitative or qualitative differences in either CT or PET between contrast media with an iodine concentration of 300 mg/ml and 370 mg/ml, respectively. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. The value of 3D contrasted-enhanced MR angiography in diagnosis of aortic dissection

    International Nuclear Information System (INIS)

    Liu Qi; Lu Jianping; Wang Fei; Wang Li; Tian Jianming; Jin Aiguo; Wang Jian

    2005-01-01

    Objective: To assess the value of three-dimensional contrast-enhanced MR angiography (3D CE-MRA) and its reconstruction in diagnosis of aortic dissection (AD). Methods: One hundred and thirty-six patients with AD underwent 3D CE-MRA with a 3D FLASH sequence after injection of 0.2 mmol Gd-DTPA per kg b. w. The source images were subtracted from mask images and transferred to computer workstation subsequently post-processed using volume rendering (VR), maximum intensity projection (MIP), multiplaner reformation (MPR) and virtual endoscopy (VE). Results: (1) Double lumen and intimal flap could be shown in all of 136 patients. There were 27 DeBakey type I dissections, 2 type II dissections and 107 type III dissections. Twenty-one cases were confirmed by surgery, and 32 cases, by DSA with endovascular graft exclusion. (2) Initial entry sites were defined in 105 cases. Compared with DSA, the depiction of 3D CE-MRA was 100% for initial entry sites and 91.4% for multi entry sites. Depiction of the initial entry sites was significantly better with VR and MPR, especially VR images. The shape, size and the relationship between the arterial orifice and the initial entry sites were clearly demonstrated with three-dimension on VR images, which was very helpful for surgery and endovascular graft exclusion. (3) The orifice of anonymous artery involved in type I dissections was 10 (10/27) , and the orifice of left subclavian artery involved in type III dissections, 10.3 percent. In 134 patients with type I and type III dissections, the kidney arterial orifice was involved in 32.1 percent; the celiac arterial orifice, 14.9 percent; the super mesenteric arterial orifice, 4.5 percent. Single artery involved was about 40.3 percent, and multi arteries, 12.7 percent

  20. Searching for an alternative oral contrast agent for GI tract MR imaging; in vitro phase, initial report

    International Nuclear Information System (INIS)

    Okla, W.; Szeszkowski, W.; Cieszanowski, A.; Golebiowski, M.

    2002-01-01

    MR has been recently considered to be suitable method for detection GI tract pathologies. A few substances (some of a natural origin) seem to act as an efficient oral MR contrast agents. The aim of this study is to find an alternative substance, which can be administrated orally to patients in order to enhance signal intensity (SI). The ideal agent should have a biphase pattern (high SI in T1 and low in T2), and should be nontoxic and cost effective. Phantom experiments were conducted with 1.5 T MR scanner. T1W and T2W sequences were used for initial estimation. Number of different agents such as: water, Gd-DTPA, barium sulfate, green tea, blueberry juice, cranberry juice, blackcurrant juice, and some more were evaluated. Signal intensity was measured by using elliptical region of interest (ROI). MR imaging in one patient with stomach cancer was also performed. In T1W-FFE sequence cranberry juice reached satisfactorily high signal (SI=1760.14). In T2W-TSE sequence this substance reduced signal intensity (SI=23.10) almost to background level. Blueberry juice appear to be the next substance capable to generate high signal (SI=1558.31) in T1W sequence (T1-TSE). MR examination of a patient with stomach adenocarcinoma (using blueberry juice as an oral contrast agent) satisfactorily depicted and delineated tumor mass on both: T1W and T2W images. Cranberry juice and blueberry juice seemed to act effectively as oral contrast agents for gastrointestinal MR imaging. Thus they need further exploration and trials. (author)

  1. Automated Determination of Arterial Input Function for Dynamic Susceptibility Contrast MRI from Regions around Arteries Using Independent Component Analysis

    Directory of Open Access Journals (Sweden)

    Sharon Chen

    2016-01-01

    Full Text Available Purpose. Quantitative cerebral blood flow (CBF measurement using dynamic susceptibility contrast- (DSC- MRI requires accurate estimation of the arterial input function (AIF. The present work utilized the independent component analysis (ICA method to determine the AIF in the regions adjacent to the middle cerebral artery (MCA by the alleviated confounding of partial volume effect. Materials and Methods. A series of spin-echo EPI MR scans were performed in 10 normal subjects. All subjects received 0.2 mmol/kg Gd-DTPA contrast agent. AIFs were calculated by two methods: (1 the region of interest (ROI selected manually and (2 weighted average of each component selected by ICA (weighted-ICA. The singular value decomposition (SVD method was then employed to deconvolve the AIF from the tissue concentration time curve to obtain quantitative CBF values. Results. The CBF values calculated by the weighted-ICA method were 41.1 ± 4.9 and 22.1 ± 2.3 mL/100 g/min for cortical gray matter (GM and deep white matter (WM regions, respectively. The CBF values obtained based on the manual ROIs were 53.6 ± 12.0 and 27.9 ± 5.9 mL/100 g/min for the same two regions, respectively. Conclusion. The weighted-ICA method allowed semiautomatic and straightforward extraction of the ROI adjacent to MCA. Through eliminating the partial volume effect to minimum, the CBF thus determined may reflect more accurate physical characteristics of the T2⁎ signal changes induced by the contrast agent.

  2. Skin-mark display in MR imaging and CT using specially produced polyvinyl alcohol gel sheets

    International Nuclear Information System (INIS)

    Mano, I.; Kogima, K.; Abe, K.; Kawana, K.; Kotake, F.; Iio, M.

    1987-01-01

    In MR imaging and XCT, clinical information drawn on the subject's skin should often be reflected on the resultant tomographic images. A typical example of such information is the radiation field outline on the patient's skin for radiation therapy. The authors therefore made a special polyvinyl alcohol (PVA) gel sheet 3 mm thick which consists of 85% water, suitable quantities of Gd-DTPA, and iodine contrast medium. The gel sheet was designed to increase the MR imaging signal intensity and x-ray absorption value. Excellent results were obtained when it was applied to the relevant regions

  3. A Feasibility Study to Determine Whether Clinical Contrast Enhanced Magnetic Resonance Imaging can Detect Increased Bladder Permeability in Patients with Interstitial Cystitis.

    Science.gov (United States)

    Towner, Rheal A; Wisniewski, Amy B; Wu, Dee H; Van Gordon, Samuel B; Smith, Nataliya; North, Justin C; McElhaney, Rayburt; Aston, Christopher E; Shobeiri, S Abbas; Kropp, Bradley P; Greenwood-Van Meerveld, Beverley; Hurst, Robert E

    2016-03-01

    Interstitial cystitis/bladder pain syndrome is a bladder pain disorder associated with voiding symptomatology and other systemic chronic pain disorders. Currently diagnosing interstitial cystitis/bladder pain syndrome is complicated as patients present with a wide range of symptoms, physical examination findings and clinical test responses. One hypothesis is that interstitial cystitis symptoms arise from increased bladder permeability to urine solutes. This study establishes the feasibility of using contrast enhanced magnetic resonance imaging to quantify bladder permeability in patients with interstitial cystitis. Permeability alterations in bladder urothelium were assessed by intravesical administration of the magnetic resonance imaging contrast agent Gd-DTPA (Gd-diethylenetriaminepentaacetic acid) in a small cohort of patients. Magnetic resonance imaging signal intensity in patient and control bladders was compared regionally and for entire bladders. Quantitative assessment of magnetic resonance imaging signal intensity indicated a significant increase in signal intensity in anterior bladder regions compared to posterior regions in patients with interstitial cystitis (p interstitial cystitis vs controls (p interstitial cystitis cases differed significantly from controls on the SF-36®, PUF (Pelvic Pain and Urgency/Frequency) and ICPI (Interstitial Cystitis Problem Index) questionnaires with no overlap in the score range in each group. ICSI (Interstitial Cystitis Symptom Index) differed significantly but with a slight overlap in the range of scores. Data suggest that contrast enhanced magnetic resonance imaging provides an objective, quantifiable measurement of bladder permeability that could be used to stratify bladder pain patients and monitor therapy. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  4. Diagnostic accuracy of low and high tube voltage coronary CT angiography using an X-ray tube potential-tailored contrast medium injection protocol.

    Science.gov (United States)

    Albrecht, Moritz H; Nance, John W; Schoepf, U Joseph; Jacobs, Brian E; Bayer, Richard R; Litwin, Sheldon E; Reynolds, Michael A; Otani, Katharina; Mangold, Stefanie; Varga-Szemes, Akos; De Santis, Domenico; Eid, Marwen; Apfaltrer, Georg; Tesche, Christian; Goeller, Markus; Vogl, Thomas J; De Cecco, Carlo N

    2018-05-01

    To compare the diagnostic accuracy between low-kilovolt peak (kVp) (≤ 100) and high-kVp (> 100) third-generation dual-source coronary CT angiography (CCTA) using a kVp-tailored contrast media injection protocol. One hundred twenty patients (mean age = 62.6 years, BMI = 29.0 kg/m 2 ) who underwent catheter angiography and CCTA with automated kVp selection were separated into two cohorts (each n = 60, mean kVp = 84 and 117). Contrast media dose was tailored to the kVp level: 70 = 40 ml, 80 = 50 ml, 90 = 60 ml, 100 = 70 ml, 110 = 80 ml, and 120 = 90 ml. Contrast-to-noise ratio (CNR) was measured. Two observers evaluated image quality and the presence of significant coronary stenosis (> 50% luminal narrowing). Diagnostic accuracy (sensitivity/specificity) with ≤ 100 vs. > 100 kVp CCTA was comparable: per patient = 93.9/92.6% vs. 90.9/92.6%, per vessel = 91.5/97.8% vs. 94.0/96.8%, and per segment = 90.0/96.7% vs. 90.7/95.2% (all P > 0.64). CNR was similar (P > 0.18) in the low-kVp vs. high-kVp group (12.0 vs. 11.1), as ws subjective image quality (P = 0.38). Contrast media requirements were reduced by 38.1% in the low- vs. high-kVp cohort (53.6 vs. 86.6 ml, P tube voltage selection with a tailored contrast media injection protocol allows CCTA to be performed at ≤ 100 kVp with substantial dose reductions and equivalent diagnostic accuracy for coronary stenosis detection compared to acquisitions at > 100 kVp. • Low-kVp coronary CT angiography (CCTA) enables reduced contrast and radiation dose. • Diagnostic accuracy is comparable between ≤ 100 and > 100 kVp CCTA. • Image quality is similar for low- and high-kVp CCTA. • Low-kVp image acquisition is facilitated by automated tube voltage selection. • Tailoring contrast injection protocols to the automatically selected kVp-level is feasible.

  5. Dynamic contrast-enhanced MRI in breast cancer treated with neoadjuvant chemotherapy: correlation with pathological response

    International Nuclear Information System (INIS)

    Li Jie; Zhang Xiaopeng; Lu Aiping; Ouyang Tao; Cao Kun; Sun Yingshi; Tang Lei

    2007-01-01

    Objective: To investigate the relationship of pathological response of breast cancer after neoadjuvant chemotherapy with the imaging findings in dynamic contrast-enhanced MRI. Methods: Forty- five patients with pathologically confirmed breast carcinoma who finished courses of neoadjuvant chemotherapy had breast MRI prior to operation. Dynamic contrast-enhanced MRI scans were performed on a 1.5 T scanner using 3D SPGR sequence before and repeated 6 times after administration of Gd-DTPA. Pathological response was assessed by a pathologist according to Miller and Payne five points classification blinded to breast MRI results. Grade 5 was defined as pCR (pathological complete response). Grade 4 and 5 were defined as major histopathological response (MHR). The type of time signal intensity curve (TIC) (three types), pattern of residual enhancement of each breast cancer were recorded and correlated with pathological findings. Fisher exact test was used for statistical analysis. Results: Grade 5 responses were achieved in seven patients; grade 4 in sixteen patients; grade 3 in sixteen patients and grade 1-2 in six patients. 70.0% (14/20) of type I time signal intensity curve correlated with MHR, while all 6 type III curves showed non-MHR response. The type of time signal intensity curve and pathological response grades had statistically significant correlation (P=0.001). 18 of the 23 cases with MHR exhibited residual enhancement,while the remaining 5 cases showed no enhancement. Of the 18 MHR cases with residual enhancement, 11 showed non-mass-like enhancement and 7 showed mass-like enhancement. The mass (non-mass) morphological pattern in dynamic contrast enhanced-MRI had statistically significant differences in pathological response (P=0.012). Conclusions Pathological response of breast carcinoma after neoadjuvant chemotherapy could be characterized using dynamic contrast-enhanced MRI by identifying patterns of residual contrast enhancement and kinetic curve. Favorable

  6. Multidetector computed tomography with triple-bolus contrast medium administration protocol for preoperative anatomical and functional assessment of potential living renal donors

    International Nuclear Information System (INIS)

    Knox, Matthew K.; Rivers-Bowerman, Michael D.; Bardgett, Harry P.; Cowan, Nigel C.

    2010-01-01

    To evaluate multidetector computed tomography (MDCT) with a triple-bolus contrast administration protocol for preoperative anatomical and functional assessment of living renal donors. Fifty-five potential living renal donors underwent MDCT of which 27 proceeded to donor nephrectomy. A triple-bolus contrast administration protocol was used for simultaneous acquisition of arterial, nephrographic, and excretory phases. MDCT images were independently reviewed in random order by two radiologists blinded to surgical anatomy findings. Diagnostic accuracy for anatomical variants was quantified by sensitivity and specificity. Differential renal function (DRF) was derived from MDCT for 54 patients and compared with technetium-99 m dimercaptosuccinic acid renography (Tc-99 m DMSA). All triple-bolus MDCT examinations were technically adequate. Accessory renal arteries and veins were identified at surgery in 33% (n = 9/27) and 22% (n = 6/27) of donor kidneys. The mean difference between MDCT-derived DRF and DMSA was 0.8% (95% CI 0.1-1.6) with 95% limits of agreement of -4.6% (95% CI -3.3 to -5.9) to 6.3% (95% CI 5.0-7.6). MDCT delivered a mean (SD, range) radiation dose of 9.5 (3.6, 3.6-17.3) mSv. MDCT with a triple-bolus contrast administration provides accurate anatomical and functional evaluation of living renal donors. (orig.)

  7. Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weight

    International Nuclear Information System (INIS)

    Erturk, S.M.; Ichikawa, T.; Sou, H.; Tsukamoto, T.; Motosugi, U.; Araki, T.

    2008-01-01

    Aim: To investigate the effects of contrast material injection duration on peak enhancement times and attenuation values of the aorta, main portal vein, and liver at MDCT when the dose of contrast material is adjusted to patient weight. Material and methods: Seventy-five patients were randomly assigned to one of five groups, with durations of injection of 25, 30, 35, 40, or 45 s. All patients were injected with 2 ml/kg iodine (300 mg/ml). Attenuation values and peak enhancement times for the aorta, main portal vein, and liver were determined. The relationship between patient weight and enhancement times and values, the differences regarding peak enhancement times, and the relationship between injection duration and enhancement values were investigated using Pearson correlation, analysis of variance (ANOVA), and Spearman rank correlation, respectively. Results: No significant correlations were seen between patient weight and peak enhancement times or values. Mean peak enhancement times for the aorta, main portal vein, and liver were 9-11 s, 18-22 s, and 30-34 s, respectively (p > 0.05). The correlations between injection duration and peak enhancement values were significant and negative. Conclusions: Regardless of patient weight and injection duration, peak enhancement times of aorta, main portal vein and liver were approximately 10, 20, and 30 s, respectively. The enhancement values tended to be higher for shorter injection durations

  8. Dominance hierarchies, diversity and species richness of vascular plants in an alpine meadow: contrasting short and medium term responses to simulated global change

    Directory of Open Access Journals (Sweden)

    Juha M. Alatalo

    2014-05-01

    Full Text Available We studied the impact of simulated global change on a high alpine meadow plant community. Specifically, we examined whether short-term (5 years responses are good predictors for medium-term (7 years changes in the system by applying a factorial warming and nutrient manipulation to 20 plots in Latnjajaure, subarctic Sweden. Seven years of experimental warming and nutrient enhancement caused dramatic shifts in dominance hierarchies in response to the nutrient and the combined warming and nutrient enhancement treatments. Dominance hierarchies in the meadow moved from a community being dominated by cushion plants, deciduous, and evergreen shrubs to a community being dominated by grasses, sedges, and forbs. Short-term responses were shown to be inconsistent in their ability to predict medium-term responses for most functional groups, however, grasses showed a consistent and very substantial increase in response to nutrient addition over the seven years. The non-linear responses over time point out the importance of longer-term studies with repeated measurements to be able to better predict future changes. Forecasted changes to temperature and nutrient availability have implications for trophic interactions, and may ultimately influence the access to and palatability of the forage for grazers. Depending on what anthropogenic change will be most pronounced in the future (increase in nutrient deposits, warming, or a combination of them both, different shifts in community dominance hierarchies may occur. Generally, this study supports the productivity–diversity relationship found across arctic habitats, with community diversity peaking in mid-productivity systems and degrading as nutrient availability increases further. This is likely due the increasing competition in plant–plant interactions and the shifting dominance structure with grasses taking over the experimental plots, suggesting that global change could have high costs to biodiversity in the

  9. Comparison of the Effect of Dual-Axis Rotational Coronary Angiography Versus Conventional Coronary Angiography on Frequency of Acute Kidney Injury, X-Ray Exposure Time, and Quantity of Contrast Medium Injected.

    Science.gov (United States)

    Di Serafino, Luigi; Turturo, Maurizio; Lanzone, Saverio; Marano, Melissa; Scognamiglio, Gabriella; Trimarco, Bruno; Cirillo, Plinio; Esposito, Giovanni; D'Agostino, Carlo

    2018-02-07

    Dual-axis rotational coronary angiography (DARCA) has already been shown to reduce both the amount of contrast medium and radiation exposure compared with conventional coronary angiography (CCA). However, a clinical benefit of such imaging modality has never been demonstrated. The aim of this study was to evaluate the efficacy of DARCA to prevent acute kidney injury (AKI) compared with CCA. Consecutive patients who underwent coronary angiography were enrolled to DARCA (n = 80) or CCA (n = 80). Patients presenting with ST-segment elevation myocardial infarction or previously underwent coronary artery bypass graft were excluded. The 2 groups were homogeneous in terms of both clinical and procedural characteristics. Total x-ray time and total amount of contrast medium were significantly lower in the DARCA group compared with the CCA group (x-ray time 3.2 minutes [1.8 to 7.0] vs 5.1 minutes [2.6 to 9.9], p = 0.002; contrast medium amount 40 ml [31 to 116] vs 80 ml [50 to 150], p <0.001). AKI more often occurred in the CCA group compared with the DARCA group (16 [20%] vs 4 [5%], p = 0.007). Moreover, in patients presenting with acute coronary syndrome (ACS) or who underwent percutaneous coronary intervention (PCI), AKI more often occurred in the CCA group compared with the DARCA group (ACS patients, 6 [29%] vs 2 [6%], p = 0.04, and PCI patients, 11 [33%] vs 0 [0%], p <0.001). In addition, in patients with high pretest probability of coronary artery disease, AKI more often occurred in the CCA group compared with the DARCA group (11 [55%] vs 2 [6%], p <0.001). In conclusion, DARCA significantly reduces both x-ray exposure and amount of contrast medium usage, thereby reducing the occurrence of AKI compared with CCA. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Influence of tri-iodinated water soluble X-ray contrast medium for uro, angio and cholangiography on the plasmic coagulation system

    International Nuclear Information System (INIS)

    Kaps, H.P.

    1982-01-01

    In-vitro coagulation studies comprising overall and individual factor determinations were carried out with the aim of clarifying the nature of unforeseen incidents arising from the use of contrast media in X-ray diagnosis. In all tests a reproducible, dose-dependent, exponential coagulation inhibition was obtained, and resulted in complete inhibition at higher dose levels. This effect occurred by a factor of ten earlier, on average, with iodine ipamide, representative of liver passage bile CM, compared to uro, and angiographic CM diatrozoate and iodine thalamate used for kidney passage. Hepatotrophic CM act initially hypercoagulative at low dises through activation of the thrombin coagulase complex; later inhibition of coagulation sets in through direct fixation on functional proteins and their subsequent denaturation. A discussion is given of the importance of direct physico-chemical toxicity, histamine liberation reactions and cellular reactions, and the controversial role of the complement system is presented. (orig./MG) [de

  11. Preoperative mapping of arterial spinal supply using 3.0-T MR angiography with an intravasal contrast medium and high-spatial-resolution steady-state

    International Nuclear Information System (INIS)

    Mordasini, Pasquale; El-Koussy, Marwan; Schmidli, Jürg; Bonel, Harald Marcel; Ith, Michael; Gralla, Jan; Schroth, Gerhard; Hoppe, Hanno

    2012-01-01

    Introduction: Preoperative mapping of the arterial spinal supply prior to thoracoabdominal aortic aneurysm repair is highly relevant because of high risk for postoperative ischemic spinal cord injuries such as paraparesis or paraplegia. Methods: Twenty-four consecutive patients prior to surgical thoracoabdominal aortic aneurysm repair were investigated. All patients underwent steady-state MR angiography (MRA) of the spinal vasculature with 3-T MRI. The sequence used was a steady-state coronary 3D FLASH with 0.7-mm isotropic voxels. MRA was performed using an intravasal contrast agent. Studies were evaluated by three readers including delineation of arterial spinal supply including both aortic origin and spinal canal entry by three readers. Results: Identification and localization of the Adamkiewicz artery and its spinal canal entry was successful in all patients. Overall depiction of the vascular anatomy was graded as very good in 3 (12.5%), good in 14 (58.4%), sufficient in 5 (20.8%), and poor in 2 (8.3%) patients. Depiction of segmental artery aortic exit level was graded as good in 6 (25.0%), sufficient in 10 (41.7%), poor in 4 (16.7%) and not identifiable in 4 (16.7%) patients. Delineation of segmental artery entry level into the spinal canal was graded as very good in 4 (16.7%), good in 11 (45.8%), sufficient in 6 (25.0%), and poor in 3 (12.5%) patients. Conclusions: The use of 3-T MRA with an intravascular contrast agent and steady-state enables AKA localization including its segmental arteries with regard to the level of aortic origin and spinal canal entry in most patients.

  12. Induction of Upregulation and Downregulation of the T-Cell Activation Marker CD98 in Patients Undergoing Contrast-Enhanced CT with Iodinated Non-Ionic Dimeric Contrast Medium

    Energy Technology Data Exchange (ETDEWEB)

    Bohm, Ingrid; Schild, Hans H. [University of Bonn, Bonn (Germany)

    2009-02-15

    This study was designed to determine prospectively the expression of the multifunctional CD98 protein in peripheral white blood cells in patients receiving iodinated contrast media (CM) for a computed tomography (CT) examination. In 12 adult patients that received non-ionic dimeric CM (iosimenol or iodixanol), the expression of CD98 was analyzed from samples of peripheral white blood cells obtained prior to, one hour, and 24 hours after CM injection by the use of flow cytometry analysis and the use of the direct immunofluorescence technique. Overall, expression of CD98 was significantly downregulated 24 hours after CM injection (51.9%+-10.8% vs. 38.8%+-16.9%; p < 0.04). Patients that received iosimenol exhibited a more pronounced but not significant decrease of CD98 expression both one hour and 24 hours after CM injection. In an analysis of specific patient responses, CD98 downregulation occurred in eight patients. In two patients, CD98 was upregulated, and in the remaining two patients, expression remained unchanged. No patient acquired an adverse CM reaction. This is the first demonstration that CM may be a regulator of CD98 expression. To determine if upregulation is associated with an increased risk for the acquisition of an adverse CM-induced hypersensitivity reaction and if downregulation is associated without a risk for the acquisition of an adverse CM induced hypersensitivity reaction, further studies with a larger population of patients are required

  13. The value of fat saturation sequences and contrast medium administration in MRI of degenerative disease of the posterior/perispinal elements of the lumbosacral spine

    Energy Technology Data Exchange (ETDEWEB)

    D' Aprile, P. [San Paolo Hospital, Department of Neuroradiology, Bari (Italy); U.O. Radiologia, Sezione di Neuroradiologia, Ospedale ' ' S. Paolo' ' , Via Caposcardicchio, Bari (Italy); Tarantino, A. [San Paolo Hospital, Department of Neuroradiology, Bari (Italy); Jinkins, J.R. [State University of New York, Department of Radiology, Downstate Medical Center, Brooklyn, NY (United States); Brindicci, D. [San Paolo Hospital, Department of Radiology, Bari (Italy)

    2007-02-15

    Degenerative-inflammatory lumbar spinal pathology is one of the most common reasons why individuals seek medical care, and low back pain is the main symptom among those most commonly associated with this pathologic condition. Pain is commonly attributed to degenerative disc disease, particularly herniated discs, but many different spinal and perispinal structures may undergo degenerative-inflammatory phenomena and produce pain: discs, bone, facet joints, ligaments and muscles. In particular, in patients with non-radicular low back pain, this syndrome may arise from changes of the posterior elements/perispinal tissues of the lumbar spine (i.e., the ''posterior vertebral compartment''). They include: facet joint pathology (e.g., osteoarthritis, joint effusion, synovitis and synovial cysts), spondylolysis, spinal/perispinal ligamentous degenerative-inflammatory changes and perispinal muscular changes. It is well known that magnetic resonance is the most sensitive imaging method for the evaluation of spinal degenerative pathology, even in the initial stages of the disease. T2-weighted sequences with fat saturation, and when indicated the use of contrast-enhanced T1-weighted images with fat saturation, permit the visualization of degenerative-inflammatory changes of the posterior elements of the lumbar spine that in most cases would have been overlooked with conventional non-fat suppressed imaging. (orig.)

  14. The value of fat saturation sequences and contrast medium administration in MRI of degenerative disease of the posterior/perispinal elements of the lumbosacral spine

    International Nuclear Information System (INIS)

    D'Aprile, P.; Tarantino, A.; Jinkins, J.R.; Brindicci, D.

    2007-01-01

    Degenerative-inflammatory lumbar spinal pathology is one of the most common reasons why individuals seek medical care, and low back pain is the main symptom among those most commonly associated with this pathologic condition. Pain is commonly attributed to degenerative disc disease, particularly herniated discs, but many different spinal and perispinal structures may undergo degenerative-inflammatory phenomena and produce pain: discs, bone, facet joints, ligaments and muscles. In particular, in patients with non-radicular low back pain, this syndrome may arise from changes of the posterior elements/perispinal tissues of the lumbar spine (i.e., the ''posterior vertebral compartment''). They include: facet joint pathology (e.g., osteoarthritis, joint effusion, synovitis and synovial cysts), spondylolysis, spinal/perispinal ligamentous degenerative-inflammatory changes and perispinal muscular changes. It is well known that magnetic resonance is the most sensitive imaging method for the evaluation of spinal degenerative pathology, even in the initial stages of the disease. T2-weighted sequences with fat saturation, and when indicated the use of contrast-enhanced T1-weighted images with fat saturation, permit the visualization of degenerative-inflammatory changes of the posterior elements of the lumbar spine that in most cases would have been overlooked with conventional non-fat suppressed imaging. (orig.)

  15. Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3{sup rd} generation dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Poole, Zachary B.; Varga-Szemes, Akos; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Canstein, Christian [Siemens Medical Solutions, Malvern, PA (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Bamberg, Fabian; Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2016-10-15

    To investigate the relationship between automated tube voltage selection (ATVS) and body mass index (BMI) and its effect on image quality and radiation dose of coronary CT angiography (CCTA). We evaluated 272 patients who underwent CCTA with 3{sup rd} generation dual-source CT (DSCT). Prospectively ECG-triggered spiral acquisition was performed with automated tube current selection and advanced iterative reconstruction. Tube voltages were selected by ATVS (70-120 kV). BMI, effective dose (ED), and vascular attenuation in the coronary arteries were recorded. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used for subjective image quality analysis. Image quality was rated good to excellent in 98.9 % of examinations without significant differences for proximal and distal attenuation (all p ≥.0516), whereas image noise was rated significantly higher at 70 kV compared to ≥100 kV (all p <.0266). However, no significant differences were observed in SNR or CNR at 70-120 kV (all p ≥.0829). Mean ED at 70-120 kV was 1.5 ± 1.2 mSv, 2.4 ± 1.5 mSv, 3.6 ± 2.7 mSv, 5.9 ± 4.0 mSv, 7.9 ± 4.2 mSv, and 10.7 ± 4.1 mSv, respectively (all p ≤.0414). Correlation analysis showed a moderate association between tube voltage and BMI (r =.639). ATVS allows individual tube voltage adaptation for CCTA performed with 3{sup rd} generation DSCT, resulting in significantly decreased radiation exposure while maintaining image quality. (orig.)

  16. Feasibility of low-dose contrast medium high pitch CT angiography for the combined evaluation of coronary, head and neck arteries.

    Directory of Open Access Journals (Sweden)

    Zhiwei Wang

    Full Text Available PURPOSE: To evaluate the image quality and radiation dose of combined heart, head, and neck CT angiography (CTA using prospectively electrocardiography (ECG-triggered high-pitch spiral scan protocol, compared with single coronary CTA. MATERIALS AND METHODS: 151 consecutive patients were prospectively included and randomly divided into three groups. Group 1 (n = 47 underwent combined heart, neck, and head CTA using prospectively ECG-triggered high-pitch spiral (Flash scan protocol with a single-phase intravenous injection of iodinated contrast and saline flush; Group 2 (n = 51 underwent single coronary CTA with Flash scan protocol; and Group 3 (n = 53 underwent single coronary CTA with prospective sequence scan protocol. All patients were examined on a dual source CT (Definition FLASH. The image quality was determined for each CT study. RESULTS: Patients of scanning protocol Group 1, 2, and 3 showed no significant differences in age, sex, heart rates, and BMI. Evaluation of coronary artery image quality showed comparable results in the three scanning protocol groups on a per patient-based analysis. In group 1, image quality was found to be sufficient to be diagnostic in all arterial segments of carotid arteries. The mean dose-length product (DLP for group 1 was 256.3±24.5 mGy×cm and was significantly higher in comparison with group 2 (93.4±19.9 mGy×cm; p < 0.001. However, there was no significant difference of DLP between group 1 and group 3 (254.1±69.9 mGy×cm. CONCLUSIONS: The combined heart, neck, and head arteries scan using prospectively electrocardiography (ECG-triggered high-pitch spiral scan protocol in 1 single examination resulted in an excellent opacification of the aorta, the carotid arteries, and the coronary arteries and provided a good image quality with low radiation dose.

  17. Dialysis and contrast media

    International Nuclear Information System (INIS)

    Morcos, Sameh K.; Thomsen, Henrik S.; Webb, Judith A.W.

    2002-01-01

    In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of dialysis membrane, duration of hemodialysis and molecular size, protein binding, hydrophilicity, and electrical charge of the contrast medium. Generally, several hemodialysis sessions are needed to removal all contrast medium, whereas it takes 3 weeks for continuous ambulatory dialysis to remove the agent completely. There is no need to schedule the dialysis in relation to the injection of iodinated or MR contrast media or the injection of contrast agent in relation to the dialysis program. Hemodialysis does not protect poorly functioning kidneys against contrast-medium-induced nephrotoxicity. Simple guidelines are given. (orig.)

  18. Dialysis and contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Morcos, Sameh K. [Department of Diagnostic Imaging, Northern General Hospital, Sheffield Teaching Hospitals NHS Trust, Sheffield S5 7AU (United Kingdom); Thomsen, Henrik S. [Department of Diagnostic Radiology 54E2, Copenhagen University Hospital at Herlev, Herlev Ringvej 75, 2730 Herlev (Denmark); Webb, Judith A.W. [Department of Diagnostic Imaging, St Bartholomew' s Hospital, London EC1A 7BE (United Kingdom)

    2002-12-01

    In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of dialysis membrane, duration of hemodialysis and molecular size, protein binding, hydrophilicity, and electrical charge of the contrast medium. Generally, several hemodialysis sessions are needed to removal all contrast medium, whereas it takes 3 weeks for continuous ambulatory dialysis to remove the agent completely. There is no need to schedule the dialysis in relation to the injection of iodinated or MR contrast media or the injection of contrast agent in relation to the dialysis program. Hemodialysis does not protect poorly functioning kidneys against contrast-medium-induced nephrotoxicity. Simple guidelines are given. (orig.)

  19. Measurement of extracellular volume and transit time heterogeneity using contrast-enhanced myocardial perfusion MRI in patients after acute myocardial infarction.

    Science.gov (United States)

    Kunze, Karl P; Rischpler, Christoph; Hayes, Carmel; Ibrahim, Tareq; Laugwitz, Karl-Ludwig; Haase, Axel; Schwaiger, Markus; Nekolla, Stephan G

    2017-06-01

    To assess the ability of dynamic contrast-enhanced myocardial perfusion MRI to measure extracellular volume (ECV) and to investigate the possibility of estimating capillary transit time heterogeneity (CTH) in patients after myocardial infarction and successful revascularization. Twenty-four perfusion data sets were acquired on a 3 Tesla positron emission tomography (PET)/MRI scanner. Three perfusion models of different complexity were implemented in a hierarchical fashion with an Akaike information criterion being used to determine the number of fit parameters supported by the data. Results were compared sector-wise to ECV from an equilibrium T 1 mapping method (modified look-locker inversion recovery (MOLLI)). ECV derived from the perfusion analysis correlated well with equilibrium measurements (R² = 0.76). Estimation of CTH was supported in 16% of sectors (mostly remote). Inclusion of a nonzero CTH parameter usually led to lower estimates of first-pass extraction and slightly higher estimates of blood volume and flow. Estimation of the capillary permeability-surface area product was feasible in 81% of sectors. Transit time heterogeneity has a measurable effect on the kinetic analysis of myocardial perfusion MRI data, and Gd-DTPA extravasation in the myocardium is usually not flow-limited in infarct-related pathology. Measurement of myocardial ECV using perfusion imaging could provide a scan-time efficient alternative to methods based on T 1 mapping. Magn Reson Med 77:2320-2330, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  20. Gd-DTPA enhanced MRI of breast: the most sensitive method for detecting multicentric carcinomas in female breast?

    International Nuclear Information System (INIS)

    Oellinger, H.; Heins, S.; Sander, B.; Schoenegg, W.; Flesch, U.; Meissner, R.; Felix, R.

    1993-01-01

    In a prospective study our purpose was to establish a clinically relevant procedure with MRBI for women with a single suspect lesion on mammography. Eight (32 %) of 25 patients with histologically confirmed carcinoma had an MCC. Seven MCC were detected with MRBI and only one was diagnosed by mammography; one was discovered with neither MRBI nor mammography. MRBI proved to be the superior technique, with a sensitivity of 0.88 compared with 0.13 for mammography. (orig.)

  1. Intracavitary application of contrast medium in the follow-up of complicated tube-drained pleural empyema: Conventional radiography vs CT; Die intrakavitaere Kontrastmittelgabe bei der Nachsorge des komplizierten langzeitdrainierten Thoraxempyems: Roentgendurchleuchtung im Vergleich zur Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Duex, M. [Radiologische Klinik, Abteilung Radiodiagnostik der Ruprecht-Karls-Univ., Heidelberg (Germany); Bischoff, H.; Schmaehl, A.; Tuengerthal, S. [Roentgenabteilung der LVA Baden, Klinik fuer Thoraxerkrankungen, Heidelberg-Rohrbach (Germany)

    1997-07-01

    Purpose: To define the value of conventional radiography compared with CT in the follow-up of complicated, long-term tube drained pleural empyema after intracavitary application of contrast medium. Methods: 28 patients with complicated pleural empyema (stage III) and longterm tube drainage were submitted to fluoroscopy of the pleural cavity and a CT of the thorax after contrast medium had been instilled into the pleural space. Both examinations were judged by the following criteria: Number and morphology of pleural cavities, quality of drainage and accompanying thoracic disease. Results: 49 pleural cavities were diagnosed. Judgement of drainage corresponded in 79% of cases and differed 21% with proof of further not drained cavities only on CT. 4 bronchopleural fistulas were diagnosed by fluoroscopy, of which only 2 were evident on CT. Accompanying thoracic disease was reliably detected by CT only. Conclusions: Diagnosis of bronchopleural fistulas and judgement of the pleural drainage is best possible using fluoroscopy after application of contrast medium into the pleural space. CT is most accurate to detect further cavities that have not been drained, to look for concomitant thoracic disease, and to judge the morphology of the pleural cavity. Conventional radiography of the pleural space is effective and recommended to be used as a first line investigation for the follow-up of stage III empyemas. Patients in poor general condition (fever, elevated blood markers indicating inflammation) should be examined by both fluoroscopy and CT. (orig.) [Deutsch] Ziel: Untersuchung zur radiologischen Nachsorge komplizierter, langzeitdrainierter Thoraxempyeme mit Hilfe der Durchleuchtung gegenueber CT nach intrakavitaerer Kontrastmittelgabe. Methoden: 28 Patienten mit kompliziertem Thoraxempyem (Stadium III) und Langzeitdrainage erhielten nach Instillation von Kontrastmittel in die Pleurahoehle eine Thoraxdurchleuchtung und ein natives Thorax-CT. Beide Untersuchungen wurden nach

  2. Comparative evaluation of modified canal staining and clearing technique, cone-beam computed tomography, peripheral quantitative computed tomography, spiral computed tomography, and plain and contrast medium-enhanced digital radiography in studying root canal morphology.

    Science.gov (United States)

    Neelakantan, Prasanna; Subbarao, Chandana; Subbarao, Chandragiri V

    2010-09-01

    This study investigated the accuracy of cone-beam computed tomography (CBCT), peripheral quantitative computed tomography (pQCT), spiral computed tomography (SCT), plain (plain digi), and contrast medium-enhanced digital radiographs (contrast digi) in studying root canal morphology. The root canal anatomy was analyzed in 95 teeth using CBCT, pQCT, SCT, plain digi, and contrast digi. After flushing out the radiopaque dye, access cavities were sealed, and the teeth were subject to the modified canal staining and clearing technique. The number of root canals (Vertucci classification and Gulabivala's additional classes) was calculated by three calibrated endodontists and two maxillofacial radiologists. Erroneous or unsuccessful identifications of root canals were statistically analyzed by one-way analysis of variance (p = 0.05). The modified canal staining and clearing technique identified an average of 1.8 root canals per mandibular central incisor, 2.3 per maxillary first premolar, 3.9 per maxillary first molar, 3.8 per maxillary and mandibular second molar, and 4.3 per mandibular first molar. CBCT and pQCT were erroneous in 0.29% and 2.05% cases, whereas SCT, contrast digi, and plain digi were unsuccessful in 15.58%, 14.7%, and 23.8%, respectively. There was a significant difference between all the methods (p technique where there was no significant difference (p > 0.05). CBCT and pQCT were as accurate as the modified canal staining and tooth clearing technique in identifying root canal systems. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  3. Computer-based image analysis in radiological diagnostics and image-guided therapy 3D-Reconstruction, contrast medium dynamics, surface analysis, radiation therapy and multi-modal image fusion

    CERN Document Server

    Beier, J

    2001-01-01

    This book deals with substantial subjects of postprocessing and analysis of radiological image data, a particular emphasis was put on pulmonary themes. For a multitude of purposes the developed methods and procedures can directly be transferred to other non-pulmonary applications. The work presented here is structured in 14 chapters, each describing a selected complex of research. The chapter order reflects the sequence of the processing steps starting from artefact reduction, segmentation, visualization, analysis, therapy planning and image fusion up to multimedia archiving. In particular, this includes virtual endoscopy with three different scene viewers (Chap. 6), visualizations of the lung disease bronchiectasis (Chap. 7), surface structure analysis of pulmonary tumors (Chap. 8), quantification of contrast medium dynamics from temporal 2D and 3D image sequences (Chap. 9) as well as multimodality image fusion of arbitrary tomographical data using several visualization techniques (Chap. 12). Thus, the softw...

  4. MRI in Crohns disease after transduodenal contrast administration using negative oral MRI constrast media; MRT-Diagnostik des Morbus Crohn nach transduodenaler Fuellung mit negativem oralem MR-Kontrastmittel

    Energy Technology Data Exchange (ETDEWEB)

    Holzknecht, N.; Helmberger, T.; Herrmann, K.; Reiser, M. [Institut fuer Klinische Radiologie, Ludwig-Maximilians-Universitaet Muenchen (Germany); Ochsenkuehn, T.; Goeke, B. [Medizinische Klinik II, Ludwig-Maximilians-Universitaet Muenchen (Germany)

    2003-01-01

    To compare the efficacy and quality of conventional and MR enteroclysis with different filling methods regarding the assessment of extension and extraluminal manifestations in Crohn's disease.Material and Methods 190 patients with known Crohn's disease were studied following small bowel enteroclysis, after oral administration or direct transduodenal filling in the MRI-department.T1- and T2-weighted breathhold MRI-scans w/o spectral fat suppression w/o i.v.Gd-DTPA were applied using negative oral superparamagnetic contrast media. Typical findings were marked bowel wall thickening with laminated wall contrast enhancement.In 135 patients 98,2% of affected bowel segments, 97,5% of stenoses and all 16 fistulas were detected,when conventional enteroclysis was employed as standard of reference.Additional important extraluminal findings such as ileoileal (n = 18), ileosigmoidal adhesions (n = 12), extraluminal abscesses (n = 35) and pseudotumors (n = 8) were visualized in 73/135 patients. Concerning the distension of jejunum and ileum, oral filling was rated significantly inferior to transduodenal filling in all small bowel segments,whereas filling in the MRI-unit was rated superior to fluoroscopic, mostly due to a mean transport time of 20 min to the MRI-unit. No clinically important findings of enteroclysis were missed when using MRI. Therefore, in patients with Crohn's disease, conventional enteroclysis can be replaced by MRI.For optimal bowel distension oral contrast administration is inferior to transduodenal filling, if a larger time delay between filling and the MRI-scan can be avoided. (orig.) [German] Zielsetzung Vergleich der diagnostischen Effizienz und Qualitaet von konventionellem und MRT-Enteroklysma mit unterschiedlichen Fuellungsmethoden und negativem oralem KM bzgl.Ausdehnung und relevanter Zusatzinformationen bei Morbus Crohn.Material und Methoden 190 Patienten mit bekanntem Morbus Crohn wurden teils nach Enteroklysma, oraler KM-Gabe, oder

  5. Dynamic contrast-enhanced MR imaging of the water fraction of normal bone marrow and diffuse bone marrow disease

    Energy Technology Data Exchange (ETDEWEB)

    Katsuya, Tomoo; Inoue, Tomio; Ishizaka, Hiroshi; Aoki, Jun; Endo, Keigo [Gunma Univ., Maebashi (Japan). School of Medicine

    2000-10-01

    To clarify the contrast-enhancement pattern of the normal hematopoietic element by isolating the signal of the water fraction in vertebral bone marrow and to investigate whether this approach can be used to characterize bone marrow pathology in several diffuse bone marrow diseases. Two groups were examined: 30 normal healthy volunteers and 19 patients with primary diffuse bone marrow disease (aplastic anemia [n=8], myelodysplastic syndrome (MDS) [n=5], chronic myelogenic leukemia (CML) [n=4], polycythemia vera [n=2]). Isolation of the signal of hematopoietic tissue was done by the chemical-shift misregistration effect. Twenty consecutive T1-weighted midsagittal lumber vertebral images were obtained immediately after the intravenous administration of Gd-DTPA of 0.1 mmol/kg body weight, and the pattern of the time-intensity curve, the peak contrast-enhancement (CE) ratio, and the washout rate (%/min) of bone marrow in normal volunteers were compared with those in patients suffering from primary diffuse bone marrow disease. The pattern of the time-intensity curve of patients with aplastic anemia showed a low peak value followed by a slow washout. However, the pattern of time-intensity curves in patients with MDS, CML, and polycythemia vera was similar to that of normal volunteers. The peak CE ratio of the water fraction in normal marrow ranged from 0.45 to 1.26 (mean {+-}S.D.: 0.87{+-}0.18). Patients with aplastic anemia showed an abnormally lower peak CE ratio of the water fraction (mean {+-}S.D.: 0.34{+-}0.19, p<0.0001). On the other hand, the peak CE ratio of the water fraction in patients with MDS was significantly higher than that of normal volunteers (mean {+-}S.D. 1.35{+-}0.39, p<0.05). In contrast, the peak CE ratio of patients with CML or polycythemia vera did not differ significantly from that of normal volunteers. The mean washout rate of patients with aplastic anemia was significantly lower than that of normal volunteers (mean {+-}S.D.: 3.50{+-}2.51 %/min

  6. Contrast medium extravasation in intravenous urography

    International Nuclear Information System (INIS)

    Tosch, U.; Becker-Gaab, C.; Hahn, D.

    1984-01-01

    Aetiology and diagnostic procedure of calyceal fornix rupture during intravenous urography are discussed. In the literature the fornix rupture is discribed as a spontaneous event - not so in the four cases presented. In two cases a sudden increase in intrapelvic pressure was due to an ureteric calculus, in the other cases an obstruction of the ureter was secondary to neoplasm. It is recommended to perform a CT as soon as a contrastmedium extravasation in intravenous urography is diagnosed. (orig.) [de

  7. MR findings of medulloblastomas and the significance of contrast enhanced MR of brain and spine for the staging

    International Nuclear Information System (INIS)

    Chung, Jae Joon; Kim, Dong Ik; Chung, Tae Sub; Lee, Yeon Hee; Suh, Jung Ho

    1994-01-01

    calcification(44.4%). Medulloblastomas revealed low to intermediate signal intensity on T1-weighted image and intermediate to moderately high signal intensity on T2-weighted image, relative to cerebellar white matter. Medulloblastomas were solid tumors with cystic necrosis, which showed inhomogeneous enhancement and subarachnoid disseminations to the intracranial and intraspinal spaces after Gd-DTPA enhancement. Gd-enhanced MR of brain and spine was an useful diagnostic modality in preoperative diagnosis and in staging of postoperative cases of medulloblastomas, which was superior to postcontrast CT or precontrast MR

  8. Effect of reduced x-ray tube voltage, low iodine concentration contrast medium, and sinogram-affirmed iterative reconstruction on image quality and radiation dose at coronary CT angiography: results of the prospective multicenter REALISE trial.

    Science.gov (United States)

    Yin, Wei-Hua; Lu, Bin; Gao, Jian-Bo; Li, Pei-Ling; Sun, Kai; Wu, Zhi-Feng; Yang, Wen-Jie; Zhang, Xiao-Qin; Zheng, Min-Wen; McQuiston, Andrew D; Meinel, Felix G; Schoepf, Uwe Joseph

    2015-01-01

    Both low tube voltage and sinogram-affirmed iterative reconstruction (IR) techniques hold promise to decrease radiation dose at coronary CT angiography (CCTA). The increased iodine contrast at low tube voltage allows for minimizing iodine load. To assess the effect of reduced x-ray tube voltage, low iodine concentration contrast medium and IR on image quality and radiation dose at CCTA. Two hundred thirty-one consecutive patients with suspected coronary artery disease were enrolled in this prospective, multicenter trial and randomized to 1 of 2 dual-source CCTA protocols: 120-kVp with 370 mgI/mL iopromide or iopamidol (n = 116; 44 women; 55.3 ± 9.8 years) or 100 kVp with 270 mgI/mL iodixanol (n = 115; 48 women; 54.2 ± 10.4 years). Reconstruction was performed with filtered back projection and IR. Attenuation, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured and image quality scored. Size-specific dose estimates and effective doses were calculated. There were no significant differences in mean arterial attenuation (406.6 ± 76.7 vs 409.7 ± 65.2 Hounsfield units; P = .739), image noise (18.7 ± 3.8 vs 17.9 ± 3.4 Hounsfield units; P = .138), signal-to-noise ratio (22.5 ± 5.4 vs 23.7 ± 6.1; P = .126), contrast-to-noise ratio (17.5 ± 5.5 vs 18.3 ± 6.1; P = .286), or image quality scores (4.1 ± 0.9 vs 4.0 ± 0.9; P > .05) between 120-kVp filtered back projection-reconstructed and 100-kVp IR-reconstructed series. Mean iodine dose was 26.5% lower (18.3 ± 0.5 vs 24.9 ± 0.9 g; P x-ray tube voltage and IR allows for decreasing the iodine load and effective radiation dose at CCTA while maintaining image quality. Copyright © 2015 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  9. Convective transport resistance in the vitreous humor

    Science.gov (United States)

    Penkova, Anita; Sadhal, Satwindar; Ratanakijsuntorn, Komsan; Moats, Rex; Tang, Yang; Hughes, Patrick; Robinson, Michael; Lee, Susan

    2012-11-01

    It has been established by MRI visualization experiments that the convection of nanoparticles and large molecules with high rate of water flow in the vitreous humor will experience resistance, depending on the respective permeabilities of the injected solute. A set of experiments conducted with Gd-DTPA (Magnevist, Bayer AG, Leverkusen, Germany) and 30 nm gadolinium-based particles (Gado CELLTrackTM, Biopal, Worcester, MA) as MRI contrast agents showed that the degree of convective transport in this Darcy-type porous medium varies between the two solutes. These experiments consisted of injecting a mixture of the two (a 30 μl solution of 2% Magnevist and 1% nanoparticles) at the middle of the vitreous of an ex vivo whole bovine eye and subjecting the vitreous to water flow rate of 100 μl/min. The water (0.9% saline solution) was injected at the top of the eye, and was allowed to drain through small slits cut at the bottom of the eyeball. After 50 minutes of pumping, MRI images showed that the water flow carried the Gd-DTPA farther than the nanoparticles, even though the two solutes, being mixed, were subjected to the same convective flow conditions. We find that the convected solute lags the water flow, depending on the solute permeability. The usual convection term needs to be adjusted to allow for the filtration effect on the larger particles in the form (1- σ) u . ∇ c with important implications for the modeling of such systems.

  10. Gadolinium neutron capture therapy for brain tumors. Biological aspects

    International Nuclear Information System (INIS)

    Takagaki, Masao; Oda, Yoshifumi; Matsumoto, Masato; Kikuchi, Haruhiko; Kobayashi, Tooru; Kanda, Keiji; Ujeno, Yowri.

    1994-01-01

    This study investigated the tumoricidal effect of gadolinium neutron capture therapy (Gd-NCT) in in vitro and in vivo systems using Gd-DTPA. In in vitro study, a certain amount of Gd-DTPA, yielding 5000 ppm Gd-n, was added to human glioma cells, T98G, upon which thermal neutrons were exposed. After irradiation, the cells were incubated and the colonies were counted 10 days later. In in vivo study, Fisher-344 rats with experimentally induced gliosarcoma cells (9L) were exposed to thermal neutrons at a fluence rate of 3E+9/s for 1 h immediately after iv injection of Gd-DTPA. Two weeks after irradiation, brain samples were histologically examined. Tumor clearance of Gd-DTPA was also determined. In vitro analysis showed that a 1% survival level was obtained at 3.75E+12 (n/cm 2 ) for the Gd (+) medium and 2.50E+13 (n/cm 2 ) for the Gd (-) medium. In in vivo analysis, the concentration of Gd in 9L-rat brain tumor after iv injection of 0.2 mg/kg Gd-DTPA was found to be less than 100 ppm, but Gd-NCT on 9L-rat brain tumor administered with a ten-fold dose showed a substantial killing effect on tumor without serious injury to the normal brain structure. The killing effect of Gd-NCT was confirmed in in vitro and in vivo systems. (N.K.)

  11. Value of 100 kVp scan with sinogram-affirmed iterative reconstruction algorithm on a single-source CT system during whole-body CT for radiation and contrast medium dose reduction: an intra-individual feasibility study.

    Science.gov (United States)

    Nagayama, Y; Nakaura, T; Oda, S; Tsuji, A; Urata, J; Furusawa, M; Tanoue, S; Utsunomiya, D; Yamashita, Y

    2018-02-01

    To perform an intra-individual investigation of the usefulness of a contrast medium (CM) and radiation dose-reduction protocol using single-source computed tomography (CT) combined with 100 kVp and sinogram-affirmed iterative reconstruction (SAFIRE) for whole-body CT (WBCT; chest-abdomen-pelvis CT) in oncology patients. Forty-three oncology patients who had undergone WBCT under both 120 and 100 kVp protocols at different time points (mean interscan intervals: 98 days) were included retrospectively. The CM doses for the 120 and 100 kVp protocols were 600 and 480 mg iodine/kg, respectively; 120 kVp images were reconstructed with filtered back-projection (FBP), whereas 100 kVp images were reconstructed with FBP (100 kVp-F) and the SAFIRE (100 kVp-S). The size-specific dose estimate (SSDE), iodine load and image quality of each protocol were compared. The SSDE and iodine load of 100 kVp protocol were 34% and 21%, respectively, lower than of 120 kVp protocol (SSDE: 10.6±1.1 versus 16.1±1.8 mGy; iodine load: 24.8±4versus 31.5±5.5 g iodine, pquality. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. A randomized controlled trial comparing hydration therapy to additional hemodialysis or N-acetylcysteine for the prevention of contrast medium-induced nephropathy: the Dialysis-versus-Diuresis (DVD) Trial.

    Science.gov (United States)

    Reinecke, H; Fobker, M; Wellmann, J; Becke, B; Fleiter, J; Heitmeyer, C; Breithardt, G; Hense, H-W; Schaefer, R M

    2007-03-01

    Contrast medium-induced nephropathy (CIN) is a serious complication with increasing frequency and an unfavorable prognosis. Previous analyses of surrogate parameters have suggested beneficial effects of hemodialysis that are assessed in this randomized clinical trial. We performed a prospective single-center trial in 424 consecutive patients with serum creatinine concentrations between 1.3- 3.5 mg/dl who underwent elective coronary angiography. Patients were randomized to one of three treatment strategies with all patients receiving pre- and postprocedural hydration: One group received no additional therapy, patients in the second group were hemodialyzed once, and the third group received oral N-acetylcysteine. The frequency of CIN (defined as an increase in serum creatinine>or=0.5 mg/dl) from 48 to 72 h after catheterization was 6.1% in the hydration-only group, 15.9% with hemodialysis treatment, and 5.3% in the N-ACC group (intention-to-treat analysis; P=0.008). There were no differences between the treatment groups with regard to increased (>or=0.5 mg/dl) serum creatinine concentrations after 30-60 days (4.8%, 5.1%, and 3.1%, respectively; P=0.700). Analyses of long-term follow-up (range 63 to 1316 days) by Cox regressions models of the study groups found quite similar survival rates (P=0.500). In contrast to other (retrospective) studies, long-term survival of patients with vs those without CIN within 72 h was not different, but patients who still had elevated creatinine concentrations at 30-60 days suffered from a markedly higher 2-year mortality (46% vs 17%, P=0.002). In conclusion, hemodialysis in addition to hydration therapy for the prevention of CIN provided no evidence for any outcome benefit but evidence for probable harm. Increased creatinine concentrations at 30-60 days, but not within 72 h, were associated with markedly reduced long-term survival.

  13. Short-Term High-Dose Vitamin E to Prevent Contrast Medium-Induced Acute Kidney Injury in Patients With Chronic Kidney Disease Undergoing Elective Coronary Angiography: A Randomized Placebo-Controlled Trial.

    Science.gov (United States)

    Rezaei, Yousef; Khademvatani, Kamal; Rahimi, Behzad; Khoshfetrat, Mehran; Arjmand, Nasim; Seyyed-Mohammadzad, Mir-Hossein

    2016-03-15

    Contrast medium-induced acute kidney injury (CIAKI) is a leading cause of acquired renal impairment. The effects of antioxidants have been conflicting regarding the prevention of CIAKI. We performed a study of vitamin E use to decrease CIAKI in patients undergoing elective coronary angiography. In a placebo-controlled randomized trial at 2 centers in Iran, 300 patients with chronic kidney disease-defined as estimated glomerular filtration rate vitamin E 12 hours before plus 400 mg vitamin E 2 hours before coronary angiography or to receive placebo. The primary end point was the development of CIAKI, defined as an increase ≥0.5 mg/dL or ≥25% in serum creatinine that peaked within 72 hours. Based on an intention-to-treat analysis, CIAKI developed in 10 (6.7%) and 21 (14.1%) patients in the vitamin E and placebo groups, respectively (P=0.037). Change in white blood cell count from baseline to peak value was greater in the vitamin E group compared with the placebo group (-500 [-1500 to 200] versus 100 [-900 to 600]×10(3)/mL, P=0.001). In multivariate analysis, vitamin E (odds ratio 0.408, 95% CI 0.170-0.982, P=0.045) and baseline Mehran score (odds ratio 1.257, 95% CI 1.007-1.569; P=0.043) predicted CIAKI. Prophylactic short-term high-dose vitamin E combined with 0.9% saline infusion is superior to placebo for prevention of CIAKI in patients undergoing elective coronary angiography. URL: https://www.clinicaltrials.gov/. Unique identifier: NCT02070679. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  14. Aspiration of Barium Contrast

    OpenAIRE

    Fuentes Santos, Cristina; Steen, Bárbara

    2014-01-01

    The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical fil...

  15. Quantitative pulmonary perfusion imaging with 3-dimensional, contrast-enhanced MR: regional difference in the perfusion parameters of healthy volunteers

    International Nuclear Information System (INIS)

    Kim, Song Soo; Seo, Joon Beom; Kim, Nam Kuk; Do, Kyung Hyun; Lee, Young Kyung; Song, Jae Woo; Lee, Jin Seong; Kim, Jin Hwan

    2007-01-01

    We wanted to evaluate the regional differences in such perfusion parameters as pulmonary blood flow (PBF), mean transit time (MTT) and pulmonary blood volume (PBV) in the entire lung of healthy volunteers with using three-dimensional, contrast-enhanced MR imaging (3D CEMRI). Six healthy volunteers underwent dynamic 3D CEMRI (TR/TE 2.7/0.6 msec; flip angle 40 .deg. ; matrix 128 x 96; reconstructed matrix 256 x 192; rectangular field of view 450 x 315 mm; coronal 100-150mm-thick x 10 slabs; temporal resolution 1.0 sec; 35 dynamic phases) For all subjects, 2 mL of Gd-DTPA mixed with 3 ml of physiologic saline was administered as a bolus at a rate of 5 mL/sec, and this was followed by 20 mL of physiologic saline flush. From the signal intensity-time curves, the PBF, MTT and PBV maps were generated using indicator dilution theories and the central volume principle on a pixel-by-pixel basis. A total of 54 round, 1-cm sized ROIs were placed in the lung in each subject (6 ROIs per slab x 9 slices except for the most posterior slab). The regional differences of the measured parameters were statistically evaluated in the gravitational direction and in the upper-mid-lower direction by one-way ANOVA tests. The calculated PBF, MTT and PBV in the entire lung were 141.8 ± 53.4 mL/100 mL/min (mean ± SD), 5.35 ± 1.38 sec, and 13.4 ± 6.48 mL/100mL, respectively. In the gravitational direction, there was a significant increase in the PBF and PBV as it goes to the posterior direction (ρ < 0.05). No statistical difference was found in PBF or PBV between the upper, mid and lower lung zone areas. Regional difference in the various perfusion parameters of the lung in healthy volunteers can be quantitatively assessed with performing 3D CEMRI

  16. Reproducibility of rest and exercise stress contrast-enhanced calf perfusion magnetic resonance imaging in peripheral arterial disease

    Directory of Open Access Journals (Sweden)

    Jiji Ronny S

    2013-01-01

    Full Text Available Abstract Background The purpose was to determine the reproducibility and utility of rest, exercise, and perfusion reserve (PR measures by contrast-enhanced (CE calf perfusion magnetic resonance imaging (MRI of the calf in normal subjects (NL and patients with peripheral arterial disease (PAD. Methods Eleven PAD patients with claudication (ankle-brachial index 0.67 ±0.14 and 16 age-matched NL underwent symptom-limited CE-MRI using a pedal ergometer. Tissue perfusion and arterial input were measured at rest and peak exercise after injection of 0.1 mM/kg of gadolinium-diethylnetriamine pentaacetic acid (Gd-DTPA. Tissue function (TF and arterial input function (AIF measurements were made from the slope of time-intensity curves in muscle and artery, respectively, and normalized to proton density signal to correct for coil inhomogeneity. Perfusion index (PI = TF/AIF. Perfusion reserve (PR = exercise TF/ rest TF. Intraclass correlation coefficient (ICC was calculated from 11 NL and 10 PAD with repeated MRI on a different day. Results Resting TF was low in NL and PAD (mean ± SD 0.25 ± 0.18 vs 0.35 ± 0.71, p = 0.59 but reproducible (ICC 0.76. Exercise TF was higher in NL than PAD (5.5 ± 3.2 vs. 3.4 ± 1.6, p = 0.04. Perfusion reserve was similar between groups and highly variable (28.6 ± 19.8 vs. 42.6 ± 41.0, p = 0.26. Exercise TF and PI were reproducible measures (ICC 0.63 and 0.60, respectively. Conclusion Although rest measures are reproducible, they are quite low, do not distinguish NL from PAD, and lead to variability in perfusion reserve measures. Exercise TF and PI are the most reproducible MRI perfusion measures in PAD for use in clinical trials.

  17. Quantification of convection-enhanced delivery to the ischemic brain

    International Nuclear Information System (INIS)

    Haar, Peter J; Broaddus, William C; Chen, Zhi-jian; Gillies, George T; Fatouros, Panos P; Corwin, Frank D

    2010-01-01

    Convection-enhanced delivery (CED) could have clinical application in the delivery of neuroprotective agents following ischemic stroke. However, ischemic brain tissue changes such as cytotoxic edema, in which cellular swelling decreases the fractional volume of the extracellular space, would be expected to significantly alter the distribution of neuroprotective agents delivered by CED. We sought to predict and characterize these effects using the magnetic resonance contrast agent gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA) as a model therapeutic agent. CED was observed using MRI in a normal rat brain and in a middle cerebral artery (MCA) occlusion rat model of brain ischemia. Gd-DTPA was infused to the caudate putamen in the normal rat (n = 6) and MCA occlusion model (n = 6). In each rat, baseline apparent diffusion coefficient images were acquired prior to infusion, and T1 maps were then acquired 13 times throughout the duration of the experiment. These T1 maps were used to compute Gd-DTPA concentrations throughout each brain. In the MCA occlusion group, CED delivered Gd-DTPA to a comparatively larger volume with lower average tissue concentrations. Following the infusion, the total content of Gd-DTPA decreased more slowly in the MCA occlusion group than in the normal group. This quantitative characterization confirms that edematous ischemic tissue changes alter the distribution of agents by CED. These findings may have important implications for CED in the treatment of brain injury, and will assist in future efforts to model the distribution of therapeutic agents

  18. Evaluating coronary reperfusion during acute myocardial infarction in a canine model by gadolinium-DTPA-enhanced magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tanabe, Kazuaki; Ishibashi, Yutaka; Shimada, Toshio (Shimane Medical Univ., Izumo (Japan)) (and others)

    1993-05-01

    In previous studies, magnetic resonance imaging (MRI) using contrast agents was found to be useful in distinguishing reperfused infarcts from nonreperfused infarcts. However, there have been only a few detailed studies using consecutive MR images for the assessment of myocardial reperfusion during an acute infarction and also no studies have been performed using a percutaneous transluminal coronary occlusion model (closed chest model). We induced acute myocardial infarction in dogs by occluding and then reperfusing the coronary artery with a balloon catheter. ECG-gated MR images were taken using the spin-echo technique before and after Gd-DTPA injection during both coronary artery occlusion and after reperfusion. We defined the intensity ratio (IR) as the signal intensity at the ischemic area divided by that at the nonischemic area on MR images and compared each image by the IR. Without Gd-DTPA, there was no difference between infarcted and normally perfused myocardium. Infarcted myocardium had a low signal intensity (IR=0.68[+-]0.14) soon after Gd-DTPA injection. This difference diminished with time. After reperfusion the infarcted myocardium had a high signal intensity (IR: 1.76[+-]0.34). We conclude that Gd-DTPA-enhanced MRI can distinguish reperfused from nonreperfused infarcts soon after Gd-DTPA administration. (author).

  19. High-resolution T1-weighted 3D real IR imaging of the temporal bone using triple-dose contrast material

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Koshikawa, Tokiko; Nakamura, Tatsuya; Fukatsu, Hiroshi; Ishigaki, Takeo; Aoki, Ikuo

    2003-01-01

    The small structures in the temporal bone are surrounded by bone and air. The objectives of this study were (a) to compare contrast-enhanced T1-weighted images acquired by fast spin-echo-based three-dimensional real inversion recovery (3D rIR) against those acquired by gradient echo-based 3D SPGR in the visualization of the enhancement of small structures in the temporal bone, and (b) to determine whether either 3D rIR or 3D SPGR is useful for visualizing enhancement of the cochlear lymph fluid. Seven healthy men (age range 27-46 years) volunteered to participate in this study. All MR imaging was performed using a dedicated bilateral quadrature surface phased-array coil for temporal bone imaging at 1.5 T (Visart EX, Toshiba, Tokyo, Japan). The 3D rIR images (TR/TE/TI: 1800 ms/10 ms/500 ms) and flow-compensated 3D SPGR images (TR/TE/FA: 23 ms/10 ms/25 ) were obtained with a reconstructed voxel size of 0.6 x 0.7 x 0.8 mm 3 . Images were acquired before and 1, 90, 180, and 270 min after the administration of triple-dose Gd-DTPA-BMA (0.3 mmol/kg). In post-contrast MR images, the degree of enhancement of the cochlear aqueduct, endolymphatic sac, subarcuate artery, geniculate ganglion of the facial nerve, and cochlear lymph fluid space was assessed by two radiologists. The degree of enhancement was scored as follows: 0 (no enhancement); 1 (slight enhancement); 2 (intermediate between 1 and 3); and 3 (enhancement similar to that of vessels). Enhancement scores for the endolymphatic sac, subarcuate artery, and geniculate ganglion were higher in 3D rIR than in 3D SPGR. Washout of enhancement in the endolymphatic sac appeared to be delayed compared with that in the subarcuate artery, suggesting that the enhancement in the endolymphatic sac may have been due in part to non-vascular tissue enhancement. Enhancement of the cochlear lymph space was not observed in any of the subjects in 3D rIR and 3D SPGR. The 3D rIR sequence may be more sensitive than the 3D SPGR sequence in

  20. Contrast-enhanced three-dimensional MR imaging using a volumetric interpolated breath-hold examination (VIBE): clinical utility in the evaluation of renal tumors

    International Nuclear Information System (INIS)

    Lee, Young Hwan; Kim, Chong Soo; Lee, Jeong Min

    2002-01-01

    To compare, in terms of technical feasibility, image quality and clinical efficacy, contrast-enhanced three-dimensional (3D) MR imaging using volumetric interpolated breath-hold examination (VIBE) with two-dimensional gradient-echo MR imaging for the evaluation of renal messes. Twenty-three patients with 25 renal masses underwent dynamic MR imaging using a 1.5-T MR system and the 3D VIBE, 2D fast low angle shot (FLASH), and combined fat saturation techniques after the injection of 20 ml of Gd-DTPA. We compared postcontrast 2D FLASH and 3D VIBE images with precontrast 2D FLASH images. For quantitative analysis, the signal-to-noise and lesion to kidney contrast-to-noise ratio of the images were calculated using the three different techniques. For qualitative analysis, two experienced radiologists analyzed the images in terms of artifacts, lesion conspicuity and delineation, and general image quality. Delineation of the anatomy of renal vasculature and pelvocalyceal systems on reconstructed 3D VIBE MIP images was also assessed. Quantitative analysis showed that the SNR of a renal mass was slightly higher at postcontrast 2D FLASG than at 3D VIBE imaging, and the SNR of renal cortex was higher at 3D VIBE than at postcontrast 2D FLASF imaging. The differences were, though, statistically insignificant (p>0.05). The CNR of al renal mass was, however, significantly higher at 3D VIBE than at 2D FLASH imaging (p<0.05). Qualitative analysis showed that general image quality was best at postcontrast 3D VIBE, followed by 2D FLASH and precontrast 2D FLASH imaging, and image artifacts were worst at post-contrast 2D FLASH image (p<0.05). In terms of lesion conspicuity and delineation, 3D VIBE gave the best results and postcontrast images were better than precontrast (p<0.05). Reconstructed angiographic and urographic images using the VIBE technique provided information about the anatomy of the renal vasculature and pelvocalyceal system. 3D VIBE MR imaging offers comparable or

  1. MRI of spondylodiscities: contribution of gadolinium-DTPA and fat suppression sequence

    Energy Technology Data Exchange (ETDEWEB)

    Cova, M.A. [Dept. of Radiology, Univ. of Trieste, Cattinara Hospital (Italy); Dalla Palma, L. [Dept. of Radiology, Univ. of Trieste, Cattinara Hospital (Italy); Pozzi-Mucelli, R.S. [Dept. of Radiology, Univ. of Trieste, Cattinara Hospital (Italy); Ricci, C. [Dept. of Radiology, Univ. of Trieste, Cattinara Hospital (Italy)

    1993-12-01

    Twenty-six patients with a clinical diagnosis of spondylodiscitis were examined with non-contrast and contrast-enhanced MRI in order to define the contribution of gadolinium-DTPA (Gd-DTPA) and different pulse sequences, including a fat suppression sequence (SPIR). Spin echo (SE) T1-weighted images before and after Gd-DTPA injection and SE T2-weighted images were obtained in all patients. Twelve patients were also examined using the SPIR sequence following Gd-DTPA injection. Signal intensity and morphological features of the disc and vertebral lesions were then evaluated. The SE T1-weighted sequence with Gd-DTPA was very effective in showing the pathological changes at the level of the disc as an area of low signal intensity surrounded by a peripheral rim of enhancement in 24 of 26 cases (92%). This feature was not visible on non-enhanced images. As regards contiguous vertebral lesions this sequence was less informative, since in 8 of 26 cases (31%) the vertebral lesions became isointense and therefore not detectable. In 12 cases there was extension into the surrounding structures (spinal canal and/or paravertebral tissues). An enhanced SE T1-weighted sequence provided good anatomical definition of the extension of the infection in the spinal canal in all cases with this type of involvement (7 of 12). Regarding the 7 cases with paravertebral extension, no extension was visible in 1 case due to the reduced contrast with the surrounding fat following Gd-DTPA injection. The enhanced SPIR sequence was very effective, particularly in detecting the lesions in the vertebral bodies, avoiding the limitation of the enhanced SE T1-weighted sequence. The SPIR sequence was also effective in showing the extension within the spinal canal and the paravertebral fat. On the basis of our results the combination of a SE T1-weighted sequence without contrast and SPIR sequence with Gd-DTPA seems to be the best approach in cases of spondylodiscitis. (orig.)

  2. MR Mammography (MRM). MR-Mammographie (MRM)

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, W.A. (Radiologische Universitaetsklinik Bonn (Germany))

    1991-01-01

    MR mammography is carried out using a special breast coil. Gd-DTPA is injected as a contrast medium. Gradient-echo sequences are superior to the formerly used spin-echo sequences in that they show a greater sensitivity to contrast media. After the advent of gradient-echo sequences, the 0.2 mmol/kg dose that used to be injected in connection with spin-echo sequences was regarded as being too high. The best results were then achieved with 0.1 mmol/kg injections amounting to no more than 50% of the former dose. Provided that magnetic resonance imaging of the breast is carried out using the spexial examination technique discussed here, it may justly be described as magnetic resonance mammography (MRM). MR criteria are defined for such conditions as carcinoma, fibroadenoma, scars, mastopathy and cysts. (GDG).

  3. Spiegel. Medium. Kunst

    DEFF Research Database (Denmark)

    Kacunko, Slavko

    and cultural perspective. From 1800 on, the great incentive was to push forward the material-physical and optical-mechanical and especially the media ‘exploitation’ of the mirror. The significance of the mirror as a central meta-medium of the visual emerged in a particularly striking way in the late 1830s....... That ricochets through media theory, theories of art and culture and through cultural historiography. A repository is one thing, a transmitter another: the distinction will act crucially on the quest for appropriate perspectives and classifications of what in terms of disciplines would rather appear...... or as synaesthesia gone mute. It stands in contrast with the mirror, which assumes the status of a medium facility or meta-medium of visual transference, encountering its only medial and operative limitation within the analogue or digital repository media. The present proposal for an artistic and cultural history...

  4. Correlative Study of Angiogenesis and Dynamic Contrast-Enhanced Magnetic Resonance Imaging Features of Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Wang, B.; Gao, Z.Q.; Yan, X.

    2005-01-01

    Purpose: To explore the correlation between contrast-enhancement patterns on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and angiogenesis by analyzing microvessel density (MVD), vascular endothelial growth factor (VEGF), and P53 protein expression in hepatocellular carcinoma (HCC). Material and Methods: MRI was performed with a GE Signa 5T MR scanner using SE and FMPSPGR sequences in 30 patients (38 lesions) during the period October 1998 to March 2000. All had histopathologically proven HCC. MR images were reviewed/analyzed retrospectively. The 30 patients were between 35 and 65 years of age. SE T1WI, PDWI, and T2WI were acquired initially. The FMPSPGR sequence was acquired in the same position. The DCE-MRI was performed in the arterial, portal vein, and delay phase after a bolus injection of Gd-DTPA. The specimens were stained immunohistochemically for CD34, VEGF, and P53. MVD was highlighted by anti-CD34 antibody staining. The enhancement features of HCC lesions were studied correlatively with the tumor MVD, VEGF, and P53 expression at protein level. Results: In the arterial phase, the results showed that MVD of HCC in the high-enhancement group (229.76±80.96) was higher than that in the equal-enhancement (173.09±61.38) and low-enhancement groups (153.00±108.58) (P <0.01, respectively). VEGF expression of HCC in the high-enhancement group (68.42%) was higher than that in the equal-enhancement (36.36%) and low-enhancement groups (38.89%) (P <0.05, respectively). In the portal vein phase, MVD of HCC in the enhancement group (259.80±93.30) was higher than that in the non-enhancement group (178.64±92.65) (P <0.05). No significant correlation was found between VEGF expression and the enhancement feature in the portal vein phase. In the delay phase, MVD of HCC in the ring-enhancement group (269.06±57.89) was significantly higher than that in the non-ring-enhancement group (144.10±88.90) (P <0.01). There was a significant difference in VEGF

  5. Contrast Materials

    Science.gov (United States)

    ... a red blood cell— and have a high degree of "echogenicity", or ability to reflect ultrasound waves. ... and radiologist to understand the potential risks and benefits of the contrast-enhanced scan. For MR imaging, ...

  6. MRI staging of urinary bladder cancer: results using a ferrous contrastographic solution (JKA1)

    International Nuclear Information System (INIS)

    Giovagnoli, A.; Ercolani, P.; De Nigris, E.; Villanova, A.

    1990-01-01

    The authors report the results of the staging of urinary bladder cancers by means of MRI using a new ferrous contrastographic solution called JKA1. Eighteen patients with proved bladder neoplasms were examined by means of MRI: the bladder was filled with physiological solution first, and then with JKA1. Six patients were studied also after filling their bladders with Gd DTPA solution (1:50). The results show that the use of JKA1, a T2-positive contrast medium, improved MR capabilities in the evaluation of small lesions (<1cm in diameter) with minimal invasion of bladder wall; MR staging accuracy was 66.6% with the physiological solution and 77.8% with JKA1. The authors confirm the need for a wider MR study, in particular of T2 lesions (a critical subject for staging and surgical management) to assess MR diagnostic capabilities

  7. Muscle lesion comparing of imaging procedures (sonography and MRT) -experimental and clinical study

    International Nuclear Information System (INIS)

    Mellerowicz, H.; Lubasch, A.; Dulce, M.; Wagner, S.; Paul, B.

    1993-01-01

    Muscle injuries in sports are more common now. Diagnosis and follow up of muscle injuries is nowadays achieved by sonography and MRT. In order to assess the two imagine procedures, a direct test for comparison of sonography and MRT was performed in an experimental study: A standardised disconnection of m. triceps surae in rats was either sutured and glued or not treated. Clinical studies were performed in 26 patients suffering from muscle trauma. Sonography was proved to be a reliable procedure especially in follow up control until full weight bearing and should be used first. Negative or doubtfull findings require further investigation by MRT. Especially contrast medium (Gd-DTPA) assisted examinations enables a long term follow up and may even show small (muscle strain) and deep lying injuries. (orig.) [de

  8. Aspiration of Barium Contrast

    Directory of Open Access Journals (Sweden)

    Cristina Fuentes Santos

    2014-01-01

    Full Text Available The aspiration of barium contrast is a rare complication that may occur during studies of the digestive tract. Barium is an inert material that can cause anywhere from an asymptomatic mechanical obstruction to serious symptoms of respiratory distress that can result in patient death. We present the case of a 79-year-old male patient in whom we observed the presence of contrast medium residue in the lung parenchyma as an incidental finding during hospitalization. When the patient’s medical file was reviewed, images were found of a barium swallow study that the patient had undergone months earlier, and we were able to observe the exact moment of the aspiration of the contrast material. The patient had been asymptomatic since the test.

  9. Percent wall thickness evaluated by Gd-DTPA enhanced cine MRI as an indicator of local parietal movement in hypertrophic cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Hirano, Masaharu [Tokyo Medical Coll. (Japan)

    1998-11-01

    Hypertrophic cardiomyopathy (HCM) is a cardiac disease, the basic pathology of which consists of a decrease in left ventricular dilation compliance due to uneven hypertrophy of the left ventricular wall. Magnetic resonance imaging (MRI) is useful in monitoring uneven parietal hypertrophy and kinetics in HCM patients. The present study was undertaken in 47 HCM patients who showed asymmetrical septal hypertrophy to determine if percent thickness can be an indicator of left ventricular local movement using cine MRI. Longest and shortest axis images were acquired by the ECG synchronization method using a 1.5 T MR imager. Cardiac function was analyzed based on longest axis cine images, and telediastolic and telesystolic parietal thickness were measured based on shorter axis cine images at the papillary muscle level. Parietal movement index and percent thickness were used as indicators of local parietal movement. The correlation between these indicators and parietal thickness was evaluated. The percent thickness changed at an earlier stage of hypertrophy than the parietal movement index, thus it is thought to be useful in detecting left ventricular parietal movement disorders at an early stage of HCM. (author)

  10. Contrast media on abdominal computed tomography

    International Nuclear Information System (INIS)

    Skalpe, I.O.; Oestensen, H.M.

    1984-01-01

    Abdominal computed tomography was performed in 55 patients before and after intravenous injection of 60 ml of a non-ionic (iohexol) or an ionic (metrizoate) contrast medium. The adverse effects were recorded and a series of measurements of attenuation values before and after the contrast medium injection was performed in the aorta and in hepatic and renal parenchyma. Only minor adverse effects were seen with both contrast media, but iohexol was clearly better tolerated than metrizoate. No difference in the enhancement properties was found between the two contrast media. (orig.)

  11. Usefulness of fat suppression MR imagings for head and neck cancers

    International Nuclear Information System (INIS)

    Kitagawa, Yoshimasa; Ishii, Yasuo; Morihiro, Hironori; Ogasawara, Toshiyuki

    1996-01-01

    Large amounts of fat and complex anatomy make the head and neck region one of the more challenging areas for MR imagings. The high signal intensity of fat on T1 weighted images (T1W1) has limited the utility of Gd-DTPA in imaging of head and neck lesions. The contrast enhanced lesions may have T1W1 signal intensity similar to fat, which results in diagnostic difficulty. A fat suppression technique used in conjunction with Gd-DTPA ensures that enhancing lesions will not be obscured by high signal from the surrounding fat or by chemical shift artifact. We evaluated the role or chemical shift imagings for fat suppression in the depiction of 15 patients with head and neck cancers. Gd-DTPA-enhanced fat suppression T1W1 were compared with conventional pre and postcontrast T1- and T2W1 using a four-point grading system (Grade 0-3) in detecting and defining the extent of primary lesions and lymphnodes. Gd-DTPA-enhanced fat suppression T1W1 (average score 2.93) which had a score of 3 in 14 patients, were superior to conventional T1W1 (0.73), postcontrast T1W1 (1.80) and T2W1 (1.67). Gd-DTPA enhanced fat suppression T1W1 were particularly beneficial in the detection of central necrosis or extracapsular invasion of neck lymphnodes as well as in defining the extent of tumor invasion to fat-containing areas such as bone marrow or cheek. Our data suggested that fat suppression technique was extremely useful to delineate the primary tumors and regional lymphnodes without increasing scan time or image postprocessing. (author)

  12. Multiscale based adaptive contrast enhancement

    Science.gov (United States)

    Abir, Muhammad; Islam, Fahima; Wachs, Daniel; Lee, Hyoung

    2013-02-01

    A contrast enhancement algorithm is developed for enhancing the contrast of x-ray images. The algorithm is based on Laplacian pyramid image processing technique. The image is decomposed into three frequency sub-bands- low, medium, and high. Each sub-band contains different frequency information of the image. The detail structure of the image lies on the high frequency sub-band and the overall structure lies on the low frequency sub-band. Apparently it is difficult to extract detail structure from the high frequency sub-bands. Enhancement of the detail structures is necessary in order to find out the calcifications on the mammograms, cracks on any object such as fuel plate, etc. In our proposed method contrast enhancement is achieved from high and medium frequency sub-band images by decomposing the image based on multi-scale Laplacian pyramid and enhancing contrast by suitable image processing. Standard Deviation-based Modified Adaptive contrast enhancement (SDMACE) technique is applied to enhance the low-contrast information on the sub-bands without overshooting noise. An alpha-trimmed mean filter is used in SDMACE for sharpness enhancement. After modifying all sub-band images, the final image is derived from reconstruction of the sub-band images from lower resolution level to upper resolution level including the residual image. To demonstrate the effectiveness of the algorithm an x-ray of a fuel plate and two mammograms are analyzed. Subjective evaluation is performed to evaluate the effectiveness of the algorithm. The proposed algorithm is compared with the well-known contrast limited adaptive histogram equalization (CLAHE) algorithm. Experimental results prove that the proposed algorithm offers improved contrast of the x-ray images.

  13. Contrast-induced nephropathy

    Energy Technology Data Exchange (ETDEWEB)

    Persson, P.B. [Inst. of Physiology, Humboldt Univ., Medizinische Fakultaet (Charite), Berlin (Germany)

    2005-11-15

    How contrast medium-induced nephropathy (CIN) comes about is not fully understood, although CIN constitutes a leading cause of renal failure. Here, a short review of clinical trials and a more thorough outline of mechanisms thought to cause CIN are outlined. Osmolality is only one of several physicochemical properties of contrast media (CM). Iso-osmolar CM are dimers, not monomers. Thus, they have physicochemical features different from other CM, e. g., in terms of viscosity (which is over fivefold greater than plasma viscosity). This may be of considerable pathophysiologic and clinical importance. There are studies providing evidence for a greater perturbation in renal functions by iso-osmolar CM in comparison to nonionic low-osmolar CM. Conversely, some previous clinical trials indicate an advantage of the iso-osmolar CM. This review highlights altered rheological properties, perturbation of renal hemodynamics, regional hypoxia, auto- and paracrine factors (adenosine, endothelin, reactive oxygen species) and direct cytotoxic effects, which are all thought to participate in causing CIN. It is concluded that the use of CM in general, and high viscous iso-osmolar CM in particular, can be deleterious to the kidney due to augmented resistance in the renal tubules. (orig.)

  14. Quantification and Assessment of the Chemical Form of Residual Gadolinium in the Brain After Repeated Administration of Gadolinium-Based Contrast Agents: Comparative Study in Rats.

    Science.gov (United States)

    Frenzel, Thomas; Apte, Chirag; Jost, Gregor; Schöckel, Laura; Lohrke, Jessica; Pietsch, Hubertus

    2017-07-01

    Multiple clinical and preclinical studies have reported a signal intensity increase and the presence of gadolinium (Gd) in the brain after repeated administration of Gd-based contrast agents (GBCAs). This bioanalytical study in rat brain tissue was initiated to investigate whether the residual Gd is present as intact GBCA or in other chemical forms by using tissue fractionation and chromatography. Rats were divided randomly in 6 groups of 10 animals each. They received 10 daily injections of 2.5 mmol/kg bodyweight of 1 of 5 different GBCAs: linear GBCAs such as gadodiamide (Omniscan; GE Healthcare), gadopentetate dimeglumine (Gd-DTPA, Magnevist; Bayer), or gadobenate dimeglumine (Multihance; Bracco) and macrocyclic GBCAs such as gadobutrol (Gadovist; Bayer) and gadoterate meglumine (Gd-DOTA, Dotarem; Guerbet) or saline. On days 3 and 24 after the last injection (p.i.), 5 randomly chosen animals of each group were killed by exsanguination, and their brains were excised and divided into cerebrum, pons, and cerebellum. The brain sections were homogenized by sonication in ice-cold buffer at pH 7.4. Soluble and insoluble fractions were separated by centrifugation, and the soluble fractions were further separated by gel permeation chromatography (GPC). The Gd concentration in all tissue fractions and in the GPC eluate was measured by inductively coupled plasma-mass spectrometry. In a recovery control experiment, all GBCAs were spiked to blank brain tissue and more than 94% recovery of Gd in the tissue fractions was demonstrated. Only traces of the administered Gd were found in the rat brain tissue on day 3 and day 24 p.i. In the animals treated with macrocyclic GBCAs, Gd was found only in the soluble brain fraction and was present solely as low molecular weight molecules, most likely the intact GBCA. In the animals treated with linear GBCAs Gd was found to a large extent in the insoluble tissue fraction. The Gd concentration in the soluble fraction was comparable to the

  15. Contrast-enhanced digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Dromain, Clarisse [Department of Radiology, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France)], E-mail: dromain@igr.fr; Balleyguier, Corinne; Adler, Ghazal [Department of Radiology, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France); Garbay, Jean Remi [Department of Surgery, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France); Delaloge, Suzette [Department of Medicine, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France)

    2009-01-15

    CEDM is a recent development of digital mammography using the intra-venous injection of an iodinated contrast agent in conjunction with a mammography examination. Two techniques have been developed to perform CEDM examinations: the temporal subtraction technique with acquisition of high-energy images before and after contrast medium injection and the dual energy technique with acquisition of a pair of low and high-energy images only after contrast medium injection. The temporal subtraction technique offered the possibility to analyze the kinetic curve of enhancement of breast lesions, similarly to breast MRI. The dual energy technique do not provide information about the kinetic of tumor enhancement but allows the acquisition of multiples views of the same breast or bilateral examination and is less sensitive to patient motion than temporal CEDM. Initial clinical experience has shown the ability of CEDM to map the distribution of neovasculature induced by cancer using mammography. Moreover, previous studies have shown a superiority of MX + CEDM, either for the assessment of the probability of malignancy than for BIRADS assessment comparing to MX alone. The potential clinical applications are the clarification of mammographically equivocal lesions, the detection of occult lesions on standard mammography, particularly in dense breast, the determination of the extent of disease, the assessment of recurrent disease and the monitoring of the response to chemotherapy. CEDM should result in a simple way to enhance the detection and the characterization of breast lesions.

  16. Development of contrast media

    International Nuclear Information System (INIS)

    Krause, W.

    1993-01-01

    Description of all contrast media (ionic and nonionic monomers, ionic and nonionic dimers) was presented. Chemotoxicity, osmolality and viscosity of some contrast agents were analyzed. The main adverse reactions to ionic and nonionic contrast media were described

  17. Evaluation of MR lymphography with positive lymphotropic contrast agent in diagnosing lymph node lesions

    International Nuclear Information System (INIS)

    Zhou Zhengyang; Yu Haiping; Chen Junkun; Zhu Bin

    2010-01-01

    Objective: To evaluate the interstital MR lymphography using positive lymphotropic contrast agent for differentiation of metastatic lymph nodes from inflammatory lymph nodes hyperplasm. Methods: Eighteen New Zealand white rabbits weighted at 2. 0-2. 5 kg were used. Inflammatory hyperplastic popliteal lymph node model was established in 9 rabbits by injection of complete freund adjuvant into the interdigitial skin of the dorsal aspect of one hind leg, and tumor-bearing popliteal lymph node model was established in another 9 rabbits by injection of VX2 tumor cell suspension. The popliteal lymph nodes of another hind leg of all 18 rabbits were assigned to the normal contral group. In each group, every rabbit underwent MR lymphography examination before and after the inoculation. Volumes of 0.2 ml of Gd [ DTPA-bis ( 2-aminoethoxy ) ethane ] polymeric contrast agent ( Gd-poly-DTPA-EOEA ) injection were injected subcutaneously into the dorsal feet of both hind legs of two groups of rabbits. T 1 -weighted 3D gradient-echo images were obtained, and source images were used to reconstruct images of MIP before and after the administration of agent. The maximum short-axis diameter (MSAD) of each popliteal lymph node was measured on the enhanced 3D MIP images, and the signal-to-noise ratio (SNR) measurement was performed in the largest popliteal node of each rabbit at each time point in delayed scan. Independent- samples t test was used to compare the sizes of popliteal nodes in MSADs between inflammatorily hyperplastic and tumor-bearing nodes after the inoculation, and the values of SNRs of popliteal nodes at each time point between inflammatorily hyperplastic, tumor-bearing and normal popliteal lymph nodes. Imaging results of the popliteal nodes were analyzed and correlated with pathological findings. Results: All of the rabbits were successfully inoculated except of the 2 rabbits in tumor-bearing nodal group. The size in MSAD of 13 inflammatorily hyperplastic and 11 tumor

  18. Hypersensitivity to contrast media and dyes.

    Science.gov (United States)

    Brockow, Knut; Sánchez-Borges, Mario

    2014-08-01

    This article updates current knowledge on hypersensitivity reactions to diagnostic contrast media and dyes. After application of a single iodinated radiocontrast medium (RCM), gadolinium-based contrast medium, fluorescein, or a blue dye, a hypersensitivity reaction is not a common finding; however, because of the high and still increasing frequency of those procedures, patients who have experienced severe reactions are nevertheless frequently encountered in allergy departments. Evidence on allergologic testing and management is best for iodinated RCM, limited for blue dyes, and insufficient for fluorescein. Skin tests can be helpful in the diagnosis of patients with hypersensitivity reactions to these compounds. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Radiographic contrast media

    International Nuclear Information System (INIS)

    Golman, K.; Holtz, E.; Almen, T.

    1987-01-01

    Contrast media are used in diagnostic radiology to enhance the X-ray attenuation between a body structure of interest and the surrounding tissue. A detail becomes perceptible on a roentgenogram only when its contrast exceeds a minimum value in relation to the background. Small areas of interest must have higher contrast than the background. The contrast effect depends on concentration of the contrast media with the body. A high contrast media concentration difference thus gives rise to more morphological details in the radiographs. Contrast media can be divided into negative contrast media such as air and gas which attenuate X-rays less than the body tissues, and positive contrast materials which attenuate X-rays more than the body tissues. The positive contrast media all contain either iodine (atomic number 53) or barium (atomic number 56) and can be divided into water-insoluble and water-soluble contrast media

  20. Liver nodules. MR imaging using extracellular gadolinium agent

    International Nuclear Information System (INIS)

    Yoshimitsu, Kengo; Honda, Hiroshi

    2009-01-01

    Extracellular gadolinium (Gd)-containing contrast medium, including gadopentetate dimeglumine (Gd-DTPA), has been playing a main role in the diagnostic MR imaging of the liver. Its significance is two-fold: assessment of the degree of neovascularity or angiogenesis in its early dynamic phase, and that of bulk of interstitium in its equilibrium phase. With the advent of gadolinium ethoxybenzyl diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA), which can be used as a dynamic study agent by bolus injection in addition to its original use as a tissue-specific agent, some possibility has been suggested that extracellular Gd agent would be no longer available in the near future in the field of liver MR imaging. Neovascularity or arterial supply of a lesion may well be assessed by Gd-EOB-DTPA, when carefully selected pulse sequence and well designed injection protocol are used, as well as by Gd-DTPA. However, the pertinent assessment of interstitium or stroma can never be achieved by Gd-EOB-DTPA or any other contrast medium present. The interstitium of neoplasm, typically called as stromal fibrosis, is generated through the interaction between the neoplasm per se and its host, and its clinicopathological significance related to disease prognosis has well been established in some disease entities. Extracellular Gd agent is the only contrast medium that can provide information regarding the tumor stroma in a simple, easy, safe and non-invasive fashion, when properly used. This review article discusses, dynamic MR imaging features of representative liver diseases, including several recent topics. From technical point of view, 3D gradient-echo sequence with fat suppression should be used for dynamic studies along with tailored injection protocol using autoinjector and saline flush. Vascularity of hepatocellular carcinoma (HCC) can now be properly assessed by dynamic MR with approximately 90% concordance with CT during hepatic arteriography. Portal phase images can be used to

  1. Addition of lacal anesthetics to contrast media. Pt. 2

    International Nuclear Information System (INIS)

    Nilsson, P.; Almen, T.; Golman, K.; Jonsson, K.; Nyman, U.; Malmoe Allmaenna Sjukhus

    1988-01-01

    The acute intravenous toxicity (i.v. LD 50 ) of solutions of the ratio 1.5 contrast media metrizoate or diatrizoate and the ratio 3.0 contrast medium metrizamide was determined in mice with and without the addition of local anesthetics to the solutions. The two local anesthetics mepivacaine or lidocaine were added to final concentrations up to 2.0 mg/ml of the contrast medium solutions. This corresponds to clinically used concentrations. All additions of local anesthetics to the solutions increased the mortalities caused by the contrast medium solutions. Addition of local anesthetics to a final concentration of 2 mg/ml approximately doubled the acute intravenous toxicity of the contrast media. The ratio 3 contrast media produce less hypertonic solutions than the ratio 1.5 contrast media and should be preferred for angiography because they cause less pain and do not require the addition of local anesthetics which increase the acute toxicity of the solutions. (orig.)

  2. Magnetic resonance imaging of post-ischemic blood-brain barrier damage with PEGylated iron oxide nanoparticles

    Science.gov (United States)

    Liu, Dong-Fang; Qian, Cheng; An, Yan-Li; Chang, Di; Ju, Sheng-Hong; Teng, Gao-Jun

    2014-11-01

    Blood-brain barrier (BBB) damage during ischemia may induce devastating consequences like cerebral edema and hemorrhagic transformation. This study presents a novel strategy for dynamically imaging of BBB damage with PEGylated supermagnetic iron oxide nanoparticles (SPIONs) as contrast agents. The employment of SPIONs as contrast agents made it possible to dynamically image the BBB permeability alterations and ischemic lesions simultaneously with T2-weighted MRI, and the monitoring could last up to 24 h with a single administration of PEGylated SPIONs in vivo. The ability of the PEGylated SPIONs to highlight BBB damage by MRI was demonstrated by the colocalization of PEGylated SPIONs with Gd-DTPA after intravenous injection of SPION-PEG/Gd-DTPA into a mouse. The immunohistochemical staining also confirmed the leakage of SPION-PEG from cerebral vessels into parenchyma. This study provides a novel and convenient route for imaging BBB alteration in the experimental ischemic stroke model.

  3. Hadrons in medium

    Indian Academy of Sciences (India)

    medium properties of hadrons. I discuss the relevant symmetries of QCD and how they might affect the observed hadron properties. I then discuss at length the observable consequences of in-medium changes of hadronic properties in reactions with ...

  4. Medium is the message

    NARCIS (Netherlands)

    Kuipers, G.; Ritzer, G.

    2012-01-01

    "The medium is the message" is a phrase coined by Canadian media theorist Marshall McLuhan (1911-1980), in his book Understanding Media: The Extensions of Man (1964). In this book, McLuhan examines the impact of media on societies and human relations, arguing for the primacy of the medium -

  5. Sarcoidosis presenting as prepatellar bursitis

    International Nuclear Information System (INIS)

    Fujimoto, Hajime; Shimofusa, Ryota; Shimoyama, Katsuhito; Nagashima, Ryota; Eguchi, Masanobu

    2006-01-01

    A 61-year-old woman complained of a subcutaneous mass in her right knee. MR images revealed a well-defined subcutaneous mass in the prepatellar region, containing some fluid and foci of short T2. The lesion showed some marginal contrast uptake after an administration of meglumine gadopentetate (Gd-DTPA), consistent with prepatellar bursitis. The pathological specimen, however, revealed subcutaneous sarcoidosis involving the bursa. (orig.)

  6. Sarcoidosis breaching the fascia and mimicking a sarcoma

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, Hajime; Ikeda, Mitsuaki; Shimofusa, Ryouta [Department of Radiology, Numazu City Hospital, 550 Harunoki-aza, Higashishiiji, Numazu, Shizuoka 410-0302 (Japan); Terauchi, Masami [Department of Plastic Surgery, Numazu City Hospital, 550 Harunoki-aza, Higashishiiji, Numazu, Shizuoka 410-0302 (Japan); Eguchi, Masanobu [Department of Pathology, Numazu City Hospital, 550 Harunoki-aza, Higashishiiji, Numazu, Shizuoka 410-0302 (Japan)

    2002-12-01

    A 55-year-old woman complained of a subcutaneous mass in her left buttock. MR images revealed an ill-defined soft tissue mass that crossed the fascia of the gluteus maximus muscle. Some surrounding edema was noted. The lesion showed some contrast uptake after administration of Gd-DTPA. An excisional biopsy revealed sarcoidosis involving both the muscle and subcutaneous tissue across the fascia, mimicking a sarcoma. (orig.)

  7. Local interstellar medium

    International Nuclear Information System (INIS)

    Crutcher, R.M.; and Radio Astronomy Laboratory, University of California, Berkeley)

    1982-01-01

    Analysis of the velocities of optical interstellar lines shows that the Sun is immersed in a coherently moving local interstellar medium whose velocity vector agrees with that of the interstellar wind observed through backscatter of solar H Lyα and He lambda584 photons. The local interstellar medium consists of both cool clouds and warm intercloud medium gas, has a mass of perhaps approx.30 M/sub sun/, does not have severe depletion of trace elements from the gas phase, and appears to be material which has been shocked and accelerated by stellar winds and supernovae associated with the Sco-Oph OB association

  8. Variable effects of radiological contrast media on thrombus growth in a rabbit jugular vein thrombosis model

    NARCIS (Netherlands)

    Levi, M. [=Marcel M.; Biemond, B. J.; Sturk, A.; Hoek, J.; ten Cate, J. W.

    1991-01-01

    We studied the effect of an ionic high osmolar contrast medium (Ioxitalamate), an ionic low osmolar contrast medium (Ioxaglate) and various nonionic low osmolar contrast media (Iopamidol, Iopromide and Iohexol) on thrombus growth in a rabbit jugular vein thrombosis model. Thrombus growth was

  9. HIRENASD medium unstructured

    Data.gov (United States)

    National Aeronautics and Space Administration — Unstructured HIRENASD mesh: - medium size (16 million nodes, 39 million elements) - for node centered solvers - 31.05.2011 - caution: dimensions in mm

  10. Concept medium programme

    DEFF Research Database (Denmark)

    Bjerrum, Peter

    2005-01-01

    The present essay is an attempt to determine the architectural project of the 21st century in relation to a modern conception of space as the medium of architecture, and of sociality as its program...

  11. Clinical evaluation of non-invasive perfusion-weighted MRI

    International Nuclear Information System (INIS)

    Takasu, Miyuki

    2000-01-01

    A spin labeling method to measure cerebral blood flow without a contrast medium was developed and applied clinically to obtain a non-invasive perfusion-weighted image. The purpose of this study is to compare the non-invasive perfusion-weighted image using FAIR with the well-established PWI using a bolus injection of Gd-DTPA. Of 41 lesions which revealed decreased perfusion, 13 were shown to be low signal intensity areas on FAIR. Therefore, detection rate of FAIR for hypoperfusion was 32%. Of 8 lesions which revealed increased perfusion, 7 demonstrated high intensity on FAIR. Therefore, detection rate of FAIR for hyperperfusion was 88%. Seven lesions were found to have a mean pixel value of zero on PWI. Of these lesions, 5 lesions could be detected as high signal intensity area on FAIR. The rCBV- and rCBF index ratios of hypoperfused lesions detected on FAIR were significantly lower than those of lesions which were not detected on FAIR (p=0.007, p=0.01). As concerns the lesions detected of FAIR, there were positive correlation between rCBV- or rCBF index ratio and FAIR signal ratio (rCBV ratio: ρ=0.873, p=0.0002, rCBF index ratio: ρ=0.858, p=0.0003). FAIR is valuable clinical tool to detect perfusion abnormality semi-quantitatively without contrast medium, although it showed relatively low detection rate for hypoperfused lesions. (author)

  12. Late adverse reactions to intravascular iodinated contrast media

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Stacul, Fulvio; Thomsen, Henrik S.; Morcos, Sameh K.

    2003-01-01

    Late adverse reactions to intravascular iodinated contrast media are defined as reactions occurring 1 h to 1 week after contrast medium injection. They have received increasing interest over the past decade, but their prevalence remains uncertain and their pathophysiology is not fully understood. The Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and to issue guidelines. An extensive literature search was carried out and summarized in a report. Based on the available information, simple guidelines have been drawn up. The report and guidelines were discussed at the 8th European Symposium on Urogenital Radiology in Genoa. Late adverse reactions after intravascular iodinated contrast medium include symptoms such as nausea, vomiting, headache, itching, skin rash, musculoskeletal pain, and fever. A significant proportion of these reactions is unrelated to the contrast medium; however, allergy-like skin reactions are well-documented side effects of contrast media with an incidence of approximately 2%. Late reactions appear to be commoner after non-ionic dimers. The majority of late skin reactions after contrast medium exposure are probably T-cell-mediated allergic reactions. Patients at increased risk of late skin reactions are those with a history of previous contrast medium reaction and those on interleukin-2 treatment. Most skin reactions are self-limiting and resolve within a week. Management is symptomatic and similar to the management of other drug-induced skin reactions. (orig.)

  13. Concept medium programme

    DEFF Research Database (Denmark)

    Bjerrum, Peter

    2005-01-01

    The present essay is an attempt to determine the architectural project of the 21st century in relation to a modern conception of space as the medium of architecture, and of sociality as its program......The present essay is an attempt to determine the architectural project of the 21st century in relation to a modern conception of space as the medium of architecture, and of sociality as its program...

  14. Evaluation of the cervical neural foramina with MR imaging

    International Nuclear Information System (INIS)

    Czervionke, L.F.; Daniels, D.L.; Ho, P.S.P.; Yu, S.; Williams, A.L.; Haughton, V.M.

    1987-01-01

    Accurately diagnosing the causes of cervical radiculopathy with MR imaging requires better understanding of the anatomic relationships in the cervical neural foramina. The cervical foramina were studied in three ways: (1) In cadavers, the paravertebral veins were injected with paramagnetic contrast material. Cryomicrotome sections were then correlated with MR images. (2) In patients, the cervical foramina were studied with MR imaging with intravenous Gd-DTPA. (3) Normal volunteers were scanned using spin-echo and gradient-echo techniques. The nerve root sheaths, ganglia, vessels, and bone margins of the cervical foramina can be well demonstrated by MR imaging. Intravenous Gd-DTPA enhances some normal structures in the foramen. The authors report on optimal pulse sequences for evaluating the cervical neural foramina

  15. Comparison of the biodistribution of manganese-54 DTPA and gadolinium-153 DTPA in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Boudreau, R.J.; Burbidge, S.; Sirr, S.; Loken, M.K.

    1987-03-01

    The biodistribution of (/sup 54/Mn)DTPA and (/sup 153/Gd)DTPA dimeglumine were investigated and compared following i.v. administration to fasting anesthetized dogs. Unlike most previously reported metal ion-DTPA complexes, (/sup 54/Mn)DTPA showed high uptakes in several organs including the liver, bile, pancreas, bowel, and kidney. This uptake was independent of the pH of the injected solution. Accumulation in these organs suggests a potential role for (Mn)DTPA as a paramagnetic contrast agent for NMR imaging. With the exception of the kidneys, (/sup 153/Gd)DTPA showed no evidence of tissue specific uptake over the course of 4 hr, consistent with it being an extracellular ion that is cleared by glomerular filtration.

  16. Diagnostic relevance of gadolinium-enhanced sequential MR imaging of the penis in patients with erectile dysfunctions

    International Nuclear Information System (INIS)

    Wein, B.; Sohn, M.; Ulose, K.; Bohndorf, K.

    1991-01-01

    This paper reports on a new functional approach, used to investigate the dynamic contrast enhancement of the penis. The inflow of Gd-DTPA in penile tissue was observed at 10-second intervals during two-dimensional FLASH MR imaging. Two dimensional FLASH gradient-echo sequences were applied in a coronal orientation through the most anterior part of the symphysis. Twelve to 15 minutes after intracavernosal injection of 20 μg of prostaglandin E1 or 25 mg of papaverine, enhancement of signal intensity in the corpora cavernosa was determined every 10 seconds for 3.5 minutes. One additional late image was obtained 10 minutes after injection. Seventy-five investigations were performed in 56 patients with proved organic erectile dysfunction. Calculated time-related Gd-DTPA uptake and intracavernosal distribution depend closely on etiology. Well-defined functional inflow patterns give hints as to the pathophysiologic cause of erectile dysfunction

  17. Displacement of the normal pituitary gland by sellar and juxtasellar tumours: surgical-MRI correlation and use in differential diagnosis

    International Nuclear Information System (INIS)

    Sumida, M.; Uozumi, T.; Yamanaka, M.; Mukada, K.; Arita, K.; Kurisu, K.; Satoh, H.; Ikawa, F.

    1994-01-01

    We compared the position of the normal pituitary gland as estimated by gadolinium (Gd)-DTPA-enhanced MRI, with its position at surgery in 40 patients with intra- and juxtasellar tumours: 22 pituitary adenomas, 4 craniopharyngiomas, 7 meningiomas, 2 germinomas, and 5 Rathke cleft cysts. In 37 of these, the normal gland showed more intense contrast enhancement than the adjacent tumour, from which it could be differentiated by Gd-DTPA-enhanced MRI, especially in the sagittal plane. The direction of displacement of the normal pituitary gland correlated well with tumour type, so that its position proved helpful in the differential diagnosis. The normal gland was typically displaced superiorly by pituitary adenomas, inferiorly by craniopharyngiomas, and anteriorly by germinomas. It showed variable displacement by Rathke cleft cysts, and was not usually displaced by meningiomas. (orig.)

  18. Contrastes de Forma: Contrastes de ilusiones (I)

    OpenAIRE

    Salvador González, José María

    1986-01-01

    Primera parte del análisis crítico de los principales movimientos artísticos representados en la Exposición Contrastes de Forma, organizada por varios museos de Nueva York en el Museo de Arte Contemporáneo de Caracas.

  19. Defined medium for Moraxella bovis.

    OpenAIRE

    Juni, E; Heym, G A

    1986-01-01

    A defined medium (medium MB) for Moraxella bovis was formulated. Nineteen strains grew well on medium MB. One strain was auxotrophic for asparagine, and another was auxotrophic for methionine. Strains of M. equi and M. lacunata also grew on medium MB. All strains had an absolute requirement for thiamine and were stimulated by or actually required the other growth factors in the medium.

  20. General perceptual contrast metric

    Science.gov (United States)

    Liberg, Anna; Hasler, David

    2003-06-01

    A combined achromatic and chromatic contrast metric for digital images and video is presented in this paper. Our work is aimed at tuning any parametric rendering algorithm in an automated way by computing how much details an observer perceives in a rendered scene. The contrast metric is based on contrast analysis in spatial domain of image sub-bands constructed by pyramidal decomposition of the image. The proposed contrast metric is the sum of the perceptual contrast of every pixel in the image at different detail levels corresponding to different viewing distances. The novel metric shows high correlation with subjective experiments. Important applications involve optimal parameter set of any image rendering and contrast enhancement technique or auto exposure of an image capturing device.

  1. Phase contrast image synthesis

    DEFF Research Database (Denmark)

    Glückstad, J.

    1996-01-01

    A new method is presented for synthesizing arbitrary intensity patterns based on phase contrast imaging. The concept is grounded on an extension of the Zernike phase contrast method into the domain of full range [0; 2 pi] phase modulation. By controlling the average value of the input phase funct...... function and by choosing appropriate phase retardation at the phase contrast filter, a pure phase to intensity imaging is accomplished. The method presented is also directly applicable in dark field image synthesis....

  2. Neuroimage in neuroecthodermical diseases. Part I: Neurofibromatosis

    International Nuclear Information System (INIS)

    Menor, F.; Marti-Bonmati, L.; Poyatos, C.; Cortina, H.; Esteban, J.M.; Vilar, J.

    1993-01-01

    Sixty-four consecutive patients with neurofibromatosis (NF) were prospectively studied: 57 had NF-1 and 7 had NF-2 according to their neurological signs, CNS lesions and the correlation between the two. All the patients with NF-1 were explored by CT and MR. In 20 cases, gadolinium (Gd-DTPA) was administered IV. Lesions were predominantly in the pallial region (58% with MR versus 27% with CT). In no case was contrast uptake observed, allowing the lesions to be differentiated from hyperuptaking parenchymatous tumors. There was no symptomatic correlation of these tumoral findings. In 17 patients, tumors of the optical pathway were detected. MR permitted better viewing of the chiasmatic involvement and the posterior pathway. The patients with NF-2 were studied directly with MR. The administration of Gd-DTPA enhanced the images of the 8 neurinomas of the acoustic apparatus and the intraspinal meningiomas present in 2 patients. MR is the method of choice for the diagnosis and followup of patients with NF. The protocol we suggest in NF-1 consists of an initial MR study of the head. The administration of Gd-DTPA can be reserved to differentiate atypical lesions that are not enhanced from hyperuptaking tumors. In patients with NF-2, MR plus contrast is the ideal method to assess the existence of tumors, especially small ones,whether cranial or spinal

  3. Neutron phase contrast imaging beamline at CIRUS, reactor, India.

    Science.gov (United States)

    Kashyap, Yogesh S; Agrawal, Ashish; Sarkar, P S; Shukla, Mayank; Roy, T; Sinha, Amar

    2012-04-01

    This paper presents the development of neutron phase contrast imaging facility at medium flux research reactor, CIRUS, India. The approach adopted for this study is innovative in the sense that both conventional and phase contrast imaging can be performed within same experiment hutch without any major modification in the experimental hutch or collimator. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Societ...

  5. Concept medium program

    DEFF Research Database (Denmark)

    Bjerrum, Peter

    2003-01-01

    The present essays is an attempt to dertermine the architecural project of the 21st century in realation to a modern conception of space as the medium of architecture, and of society as its program. This attempt adopts the internal point of view of an architect in describing a modern architectura...

  6. Radon in geological medium

    International Nuclear Information System (INIS)

    Hricko, J.

    1995-01-01

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a v has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km 2 . The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a v > 50 kBq/m 3 ). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs

  7. Compressive Phase Contrast Tomography

    International Nuclear Information System (INIS)

    Maia, Filipe; MacDowell, Alastair; Marchesini, Stefano; Padmore, Howard A.; Parkinson, Dula Y.; Pien, Jack; Schirotzek, Andre; Yang, Chao

    2010-01-01

    When x-rays penetrate soft matter, their phase changes more rapidly than their amplitude. Interference effects visible with high brightness sources creates higher contrast, edge enhanced images. When the object is piecewise smooth (made of big blocks of a few components), such higher contrast datasets have a sparse solution. We apply basis pursuit solvers to improve SNR, remove ring artifacts, reduce the number of views and radiation dose from phase contrast datasets collected at the Hard X-Ray Micro Tomography Beamline at the Advanced Light Source. We report a GPU code for the most computationally intensive task, the gridding and inverse gridding algorithm (non uniform sampled Fourier transform).

  8. Describing contrast across scales

    Science.gov (United States)

    Syed, Sohaib Ali; Iqbal, Muhammad Zafar; Riaz, Muhammad Mohsin

    2017-06-01

    Due to its sensitive nature against illumination and noise distributions, contrast is not widely used for image description. On the contrary, the human perception of contrast along different spatial frequency bandwidths provides a powerful discriminator function that can be modeled in a robust manner against local illumination. Based upon this observation, a dense local contrast descriptor is proposed and its potential in different applications of computer vision is discussed. Extensive experiments reveal that this simple yet effective description performs well in comparison with state of the art image descriptors. We also show the importance of this description in multiresolution pansharpening framework.

  9. Late adverse reactions to intravascular iodine based contrast media

    DEFF Research Database (Denmark)

    Bellin, Marie-France; Stacul, Fulvio; Webb, Judith A W

    2011-01-01

    DEFINITION: Late adverse reactions (LAR) to contrast media (CM) are defined as reactions occurring 1 h to 1 week after exposure. NEED FOR REVIEW: In view of more prospective studies of LAR and new data about their pathophysiology, the Contrast Medium Safety Committee (CMSC) of the European Society...... or delayed reading intradermal). The main risk factors for LAR are a previous reaction to contrast medium, a history of allergy, and interleukin-2 treatment. Most skin reactions are mild or moderate and self-limiting. MANAGEMENT: Management is symptomatic and similar to the management of other drug...

  10. Prolonged retainment of contrast media in renal tumours by oily X-ray contrast media

    International Nuclear Information System (INIS)

    Ryzkov, V.K.; Anisimov, V.N.

    1990-01-01

    In 194 patients with renal tumours an angiographic investigation with the oily X-ray contrast medium Iodolipol was carried out. A selective tropism of oily X-ray contrast media was found in the malignant zones only. The application of the preparation caused no complications. The oily X-ray contrast medium persisted in the tumours over several weeks or months. After embolization of the renal arteria a moderate size reduction of malign tumours in the first 10-14 d was seen. The ability of Iodolipol for a lasting retainment in malign tumour tissue allows a follow-up of the involution of the pathologic focus after arterial embolization of the tumour vessels. (author)

  11. Contrast media in urography, angiography and computerized tomography

    International Nuclear Information System (INIS)

    Taenzer, V.; Zeitler, E.

    1983-01-01

    The fact that new contrast media have been introduced in Germany or are currently undergoing clinical trials prompted the authors to assemble available experiences in a special edition of ''Roentgen-Fortschritte''. Particular prominence is given in the publication to preclinical and clinical experiences with another new non-ionic contrast medium, Iopromide. Experimental and clinical studies both indicate changes in certain clinically pertinent properties of the new contrast media. (orig./MG) [de

  12. Contrast enhancement of the gyri in herpes simplex encephalitis

    International Nuclear Information System (INIS)

    Schumacher, K.A.; Langer, M.; Langer, R.

    1982-01-01

    A case of herpes simplex encephalitis was examined by computer tomography. Both cerebral hemispheres showed contrast enhancement of the gyri. The cause of this is considered. The increased contrast medium accumulation in the affected areas is probably due to the marked vascular proliferation which can be demonstrated anatomically, and to the rapid escape of contrast from the capillaries into the interstitial spaces. The findings of other authors, which differ somewhat, are discussed. (orig.) [de

  13. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    International Nuclear Information System (INIS)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J.; Kreienberg, R.

    1999-01-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.)

  14. Generalized Phase Contrast

    CERN Document Server

    Glückstad, Jesper

    2009-01-01

    Generalized Phase Contrast elevates the phase contrast technique not only to improve phase imaging but also to cross over and interface with diverse and seemingly disparate fields of contemporary optics and photonics. This book presents a comprehensive introduction to the Generalized Phase Contrast (GPC) method including an overview of the range of current and potential applications of GPC in wavefront sensing and phase imaging, structured laser illumination and image projection, optical trapping and manipulation, and optical encryption and decryption. The GPC method goes further than the restrictive assumptions of conventional Zernike phase contrast analysis and achieves an expanded range of validity beyond weak phase perturbations. The generalized analysis yields design criteria for tuning experimental parameters to achieve optimal performance in terms of accuracy, fidelity and light efficiency. Optimization can address practical issues, such as finding an optimal spatial filter for the chosen application, ...

  15. Mamografia Espectral de Contraste

    OpenAIRE

    Martins, Inês Santiago; Pereira, Inês; Pacheco, Hugo Pisco; Moutinho, Leonor

    2014-01-01

    A mamografia de contraste é uma aplicação recente possível com a mamografia digital directa, que utiliza contraste iodado endovenoso tendo como princípio a neovascularização induzida no cancro da mama, permitindo obter informação morfológica e funcional. Na mamografia espectral de contraste realiza-se uma aquisição simultânea com alta e baixa energia para cada incidência após administração de contraste iodado endovenoso. É depois feita uma imagem recombinada em que são realçadas as áreas que ...

  16. Generalized phase contrast:

    DEFF Research Database (Denmark)

    Glückstad, Jesper; Palima, Darwin

    (GPC) method including an overview of the range of current and potential applications of GPC in wavefront sensing and phase imaging, structured laser illumination and image projection, optical trapping and manipulation, and optical encryption and decryption. The GPC method goes further than......Generalized Phase Contrast elevates the phase contrast technique not only to improve phase imaging but also to cross over and interface with diverse and seemingly disparate fields of contemporary optics and photonics. This book presents a comprehensive introduction to the Generalized Phase Contrast...... efficiency. Optimization can address practical issues, such as finding an optimal spatial filter for the chosen application, and can even enable a Reverse Phase Contrast mode where intensity patterns are converted into a phase modulation....

  17. Medium-energy physics

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    One of the basic challenges of medium-energy physics is the development of a clear picure of the manner in which pions propagate in nuclear matter. Since the pion is a basic quantum of the nuclear force, understanding its propagation in nuclei contributes to our understanding of the basic nature of nuclear forces. Key to such understanding is a comprehensive and precise experimental description of pion interactions both with complex nuclei and few nucleon systems. This is a major objective of the ANL effort in medium-energy physics. Experiments are carried out as a part of a comprehensive nuclear program, and, because of this perspective, the pion studies are expected to give new insights into the nature of nuclear forces. At the present time, almost all experimental activity is concentrated on measurements using various pion beams of the Los Alamos Meson Physics Facility

  18. Liquid chromatographic extraction medium

    Science.gov (United States)

    Horwitz, E. Philip; Dietz, Mark L.

    1994-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  19. Hadrons in the medium

    International Nuclear Information System (INIS)

    Leupold, Stefan

    2005-01-01

    QCD, the theory of the strong interaction, has a non-trivial vacuum structure. One way to characterize this structure is by means of non-vanishing matrix elements of quark or gluon operators, the condensates. In hot and/or dense enough strongly interacting media, QCD is subject to phase transitions or rapid crossovers. Consequently, the condensates typically change with density and temperature. An exciting aspect of hadron physics is the question how these changes affect the properties of hadrons which are put in a strongly interacting environment. Here vector mesons deserve special attention as they couple directly to (virtual) photons. The latter can decay into dileptons which leave the strongly interacting system untouched. Via that process information about possible in-medium modifications of the vector mesons can be carried to the detectors. With the ω-meson as an example I will review our current understanding of the connections between in-medium changes of condensates and the in-medium changes of the properties of hadrons. (author)

  20. Computed tomography after the intra-arterial and intravenous administration of contrast media

    International Nuclear Information System (INIS)

    Young, S.W.

    1981-01-01

    In computed tomography (CT) body scanning, the amount of contrast medium which has accumulated in a tissue is related to the delivery of the contrast agent to the tissue and the contrast medium extraction ratio of the tissue. The two main tissue characteristics responsible for differential contrast medium accumulation are capillary leak and differences in the size of the interstitial space. Given two tissues which leak contrast medium the best CT scanning methodology consists of delivering a rapid bolus of as high a concentration of contrast medium as can be biologically safely delivered. In order to assess the rapid pharmacokinetics, dynamic CT scanning throughout the passage of the bolus is the best technique to employ. Given two tissues, one of which leaks contrast medium and one which does not, optimal technique would utilize a sustained drip infusion, subsequently stopping the infusion, and after the blood pool has declined, obtaining CT scans through the area of interest. The accumulated tissue levels are directly related to the administered concentration, and on this basis, intra-arterial administration is superior to intravenous administration in producing contrast enhancement. The routine intra-arterial administration of contrast medium, although superior, has little practical application in the clinical setting. The contrast enhancement of blood vessels, however, is probably best produced by a sustained bolus infusion, preferably delivered into the vascular structure to be evaluated (i.e., the left foot if the left external iliac vein is to be evaluated). (Auth.)

  1. A survey of contrast media used in coronary angiograph

    International Nuclear Information System (INIS)

    Weikl, A.; Hubmann, M.

    1982-01-01

    In recent years, various contrast media have been developed for use in coronary angiography. These contrast media may be divided into ionic contrast media of high osmolality, those of low osmolality, and nonionic contrast materials. We conducted our own clinical studies with 40 patients. In random succession a standard contrast medium (ionic, of high osmolality) and a new-generation contrast medium (either nonionic or ionic with low osmolality) were injected into the right and left coronary arteries. After each injection we measured the systolic and diastolic blood pressure using a liquid-filled coronary catheter. In addition, the change in the length of the cardiac cycle was registered in terms of the R-R interval (in ms) and at the same time, leads I, II, and III of the ECG were recorded. We studied the influence of the various contrast media on the activity of ATPase in in vitro experiments, using Lasser and Lang's. When ionic contrast media of low osmolality and nonionic contrast media were utilized the heart rate showed no change. Disturbances of rhythm such as ventricular tachycardia or fibrillation were not observed. All of the contrast media used produced the same ECG changes. These changes can be ascribed to the inhibition of ATPase. The arterial blood pressure was lowered significantly only by ionic contrast media of high osmolality only. (orig.)

  2. Consideration of Adverse Reaction to MDCT Contrast Media

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Won Seok; Shin, Seong Gyu [Dept. of Radiology, Dong A University Medical Center, Busan (Korea, Republic of)

    2012-03-15

    In this experiment, we investigated 82 patients who suffered adverse reactions due to contrast medium. We selected the subjects out of 21,178 people who had an intravenous injection of contrast medium to undergo MDCT examination at one university hospital in Busan in 2007. As a result, the largest groups of the patients were as follows. 52.4% of the patients were male when classify by gender; 28.0% of the patients were 50's by age; 45% of the patients got when it was spring(April and March); 75.6% of the patients had a side effects when the speed of injection is 2.5 mL/sec; 58.5% of the patients were suffered when the volume of injected contrast medium is over 130 mL. Urticaria was the main symptom of side effect as 26.8%. And the main treatment for the effect was alleviating the symptoms before making patients to return home. Thus, practical preventive measures are needed as follows: use the OCS system to observe warning signs at risky patients, secure warming spaces for patients to cope with season changing, prepare enough emergency kits for the patients in danger, and establish CPR call systems, explain the risk of contrast medium and get agree about using contrast medium.

  3. Phase Contrast Imaging

    DEFF Research Database (Denmark)

    1996-01-01

    The invention relates to a method and a system for synthesizing a prescribed intensity pattern based on phase contrast imaging that is not based on the assumption of prior art methods that the pahase shift phi is less than 1 radian. An improved method based on a simple imaging operation with a si......The invention relates to a method and a system for synthesizing a prescribed intensity pattern based on phase contrast imaging that is not based on the assumption of prior art methods that the pahase shift phi is less than 1 radian. An improved method based on a simple imaging operation...

  4. Spiegel. Medium. Kunst

    DEFF Research Database (Denmark)

    Kacunko, Slavko

    to human talent, came the millennia of untiring labours and the play of art and science and thought. The human love-affair with reflection (to cite Mark Pendergast’s subtitle - Mirror/Mirror: A History of the Human Love Affair with Reflection [New York 2003]) has always been a platonic one and I hold...... and cultural perspective. From 1800 on, the great incentive was to push forward the material-physical and optical-mechanical and especially the media ‘exploitation’ of the mirror. The significance of the mirror as a central meta-medium of the visual emerged in a particularly striking way in the late 1830s...

  5. DENSE MEDIUM CYCLONE OPTIMIZATON

    Energy Technology Data Exchange (ETDEWEB)

    Gerald H. Luttrell; Chris J. Barbee; Peter J. Bethell; Chris J. Wood

    2005-06-30

    Dense medium cyclones (DMCs) are known to be efficient, high-tonnage devices suitable for upgrading particles in the 50 to 0.5 mm size range. This versatile separator, which uses centrifugal forces to enhance the separation of fine particles that cannot be upgraded in static dense medium separators, can be found in most modern coal plants and in a variety of mineral plants treating iron ore, dolomite, diamonds, potash and lead-zinc ores. Due to the high tonnage, a small increase in DMC efficiency can have a large impact on plant profitability. Unfortunately, the knowledge base required to properly design and operate DMCs has been seriously eroded during the past several decades. In an attempt to correct this problem, a set of engineering tools have been developed to allow producers to improve the efficiency of their DMC circuits. These tools include (1) low-cost density tracers that can be used by plant operators to rapidly assess DMC performance, (2) mathematical process models that can be used to predict the influence of changes in operating and design variables on DMC performance, and (3) an expert advisor system that provides plant operators with a user-friendly interface for evaluating, optimizing and trouble-shooting DMC circuits. The field data required to develop these tools was collected by conducting detailed sampling and evaluation programs at several industrial plant sites. These data were used to demonstrate the technical, economic and environmental benefits that can be realized through the application of these engineering tools.

  6. Iodinated contrast media nephrotoxicity

    International Nuclear Information System (INIS)

    Meyrier, A.

    1994-01-01

    In the late seventies, iodinated contrast agents (ICA) were considered to be a major cause of acute iatrogenic renal failure. Over the last decade new contrast agents have been synthesized, nonionic and less hyperosmolar. The incidence of acute renal failure due to ICAs, varies from 3.7 to 70% of cases according to the series, with an average figure of 10.2%. The pathophysiology of ICA nephrotoxicity was mainly studied in laboratory animal models. Three main factors are involved in an inducing ICA-mediated decrease in glomerular filtration rate: reduction of the renal plasma flow, a direct cytotoxic effect on renal tubular cells and erythrocyte alteration leading to intra-renal sludge. Excluding dysglobulinemias with urinary excretion of immunoglobulin light chains, which represent a special case of maximum nephrotoxicity, 4 main risk factors of renal toxicity have been identified in nondiabetic subjects: previous renal failure with serum creatinine levels greater than 140 μmol per liter, extracellular dehydration, age over 60 and use of high doses of ICA and/or repeated ICA injections before serum creatinine levels return to baseline. Preventive measures for avoiding ICA nephrotoxicity are threefold: maintain or restore adequate hydration with saline infusion, stop NSAID treatment several days before ICA administration, and allow a 5 day interval before repeating contrast media injections. New, nonionic and moderately hyperosmolar contrast agents appear to be much less nephrotoxic than conventional ICAs in laboratory animals and in high-risk patients. It is advisable to select such contrast media for investigating high-risk patients. This approach was recently substantiated in well designed, randomized clinical studies which included more than 2 000 patients. (author)

  7. Dynamic MR imaging: Follow-up study after femoral head core decompression and rhBMP-2 instillation in patients with avascular necrosis of the femoral head; Dynamische Magnetresonanztomographie (MRT): Verlaufsbeobachtung nach Femurkerndekompression und Auffuellung mit rekombinantem, humanem Bone morphogenetic Protein-2 (rhBMP-2) bei avaskulaerer Femurkopfnekrose

    Energy Technology Data Exchange (ETDEWEB)

    Schedel, H. [Klinik Prof. Schedel, Kellberg (Germany); Schneller, A. [Humboldt-Universitaet, Berlin (Germany). Klinik fuer Allgemein- und Transplantationschirurgie; Vogl, T.; Mueller, H.F.; Maeurer, J.; Felix, R. [Humboldt-Universitaet, Berlin (Germany). Strahlenklinik und Poliklinik; Suedkamp, N. [Humboldt-Universitaet, Berlin (Germany). Unfall- und Wiederherstellungschirurgie; Eisenschenk, A. [Freie Univ. Berlin (Germany). Orthopaedische Klinik und Poliklinik

    2000-07-01

    Material and Methods: Six patients with avascular necrosis of the femoral head ARCO-stage I- or II-lesions were treated surgically by femoral head core decompression. Three of these patients were additionally treated with rhBMP-2-instillation. The progression or regression could be confirmed by T1- and T2-weighted spinecho-sequences (zero, four, ten, sixteen weeks and 24 months follow up). Results: Corresponding ARCO-classification with partly more sensitive measurement of vitality signs in comparison to the optical X-ray classification. The objective, quantitative measurement of signalintensity post contrast medium reduces the influence of experience and level of education. The dynamic sequences results are reproducable. (orig.) [German] Material und Methoden: Sechs Patienten mit avaskulaerer Nekrose des Femurkopfes des Stadiums I oder II nach ARCO wurden einer Femurkerndekompression unterzogen. Drei dieser Patienten erhielten zusaetzlich eine rhBMP-2-Auffuellung. Zum Zeitpunkt null, vier, zehn, sechszehn Wochen und 24 Monaten post OP erfolgte die kernspintomographische Untersuchung mit T1- und T2-gewichteten Sequenzen unter besonderer Beruecksichtigung der dynamischen Untersuchungssequenz nach Gabe von Gd-DTPA (Gadopentetsaeure, Dimegluminsalz; Magnevist {sup trademark}) zur Dokumentation der Signalintensitaetssteigerung pro Zeiteinheit in der Nekroseregion. Ergebnisse: Uebereinstimmende Stadienklassifikation nach ARCO mit zum Teil empfindlicherer Messung von Vitalitaetszeichen im Vergleich zu rein visuellen roentgenologischen Einteilung. Die objektive, quantitative Messung des Signalintensitaetssteigerungsverhaltens nach Kontrastmittelgabe im Bereich der Femurkopfnekrose kann den Einfluss von subjektiven Eigenschaften des Untersuchers (Erfahrung, Ausbildungsstand) reduzieren, wobei die Ergebnisse der Dynamiksequenzen objektiv reproduzierbar sind. (orig.)

  8. Dynamic double-echo perfusion study of cervix-carcinomas before and after radiation at a 0.5T routine scanner

    International Nuclear Information System (INIS)

    Neumann, U.; Klengel, S.; Kaulen, F.; Schorcht, J.

    1997-01-01

    There is an increasing interest in non-invasive measurement of hemodynamic parameters in tumors. MRI is a valuable method for the evaluation and morphological staging of cervix carcinomas. The sensitivity to radiation should correlate with the pathoanatomical grade of vascularization. We tested the value of perfusion imaging in cervix tumors before and after radiation to optimize therapy. In 38 patients with cervix carcinoma (stage T2-T4) we simultaneously measured dynamic T 1 and T 2 * signal changes after bolus application of the paramagnetic contrast medium Gd-DTPA. We detected 3 patterns of uncorrected simultaneous dynamic T 1 and T 2 * signal changes in cervix tumors, which allows the differentiation of high, reduced and no T 2 * signal loss. Most tumors with a strong perfusion effect showed good regression during and after radiation therapy. More than 60% of cervix carcinomas with low or no perfusion effects were characterized by incomplete tumor reduction. Further study is necessary to prove the statistical significance allowing prospective differentiation of cervix tumors into therapy-responders and non-responders. (orig.)

  9. MRI in intraspinal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, R.K. (Dept. of Radiology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India)); Gupta, S. (Dept. of Radiology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India)); Kumar, S. (Dept. of Radiology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India)); Kohli, A. (Dept. of Neurology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India)); Misra, U.K. (Dept. of Neurology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India)); Gujral, R.B. (Dept. of Radiology, Sanjay Gandhi Postgraduate Inst. of Medical Sciences, Lucknow (India))

    1994-01-01

    We studied 20 patients with intraspinal tuberculosis (TB), to characterise the MRI features of tuberculous meningitis and myelitis. MRI leptomeningitis and intramedullary involvement in 11 patients, intramedullary lesions alone in 5, leptomeningitis alone in 2, and isolated extradural disease in 2. TB leptomeningitis was characterised by loculation of the cerebrospinal fluid (CSF), nerve root thickening and clumping (seen only in the lumbar region) or complete obliteration of the subarachnoid space on unenhanced images. Gd-DTPA-enhanced images proved useful in 6 cases, revealing linear enhancement of the surface of the spinal cord and nerve roots or plaque-like enhancement of the dura-arachnoid mater complex. Intramedullary lesions included tuberculomas (8), cord oedema (5) and cavitation (3). In seven cases of intramedullary tuberculoma multiple lesions with skip areas were seen, without significant cord swelling. One patient had an isolated lesion in the conus medullaris. The lesions were iso- or hypointense on T1-weighted images, iso-, hypo- or hyperintense on T2-weighted images and showed rim or nodular enhancement with contrast medium. (orig.)

  10. Mamografia com contraste

    OpenAIRE

    Baptista, Rita; Silva, Carina; Reis, Cláudia

    2016-01-01

    O estudo pretendeu apresentar as indicações clínicas, vantagens e princípios da mamografia com contraste, identificar as evoluyções tecnológicas para a mamografia com contraste e caracterizar as práticas e os desafios dos técnicos de radiologia do Hospital de Santarém (único no país a utilizar esta técnica). O cancro da mama é uma das principais causas de morte nas mulheres, em todo o mundo, mas principalmente nos Estados Unidos da América, Canadá, Europa Ocidental e Austrália. Em Portugal, e...

  11. Current iodinated contrast media

    International Nuclear Information System (INIS)

    Stacul, F.

    2001-01-01

    The number of scientific papers on iodinated contrast media is declining. Indeed, comparative trials between high-osmolality and low-osmolality agents largely showed the higher safety and tolerability of the latter, and this is no longer a matter of discussion. Only financial constraints could prevent a total conversion to low-osmolality agents. Research comparing low-osmolality (nonionic monomers, ionic dimer) and iso-osmolality contrast media (nonionic dimers) are still ongoing. Both classes of nonionic compounds proved safer than the ionic dimer. The relative merits of nonionic monomers and nonionic dimers are a matter for debate, and criteria for a selective use of different agents for different procedures could be discussed. (orig.)

  12. Transport phenomena in sharply contrasting media with a diffusion barrier

    International Nuclear Information System (INIS)

    Dvoretskaya, O A; Kondratenko, P S

    2011-01-01

    Using the advection–diffusion equation, we analytically study contaminant transport in a sharply contrasting medium with a diffusion barrier due to localization of a contaminant source in a low-permeability medium. Anomalous diffusion behavior and a crossover between different transport regimes are observed. The diffusion barrier results in exponential attenuation of the source power, retardation of the contaminant plume growth and modification of the concentration distribution at large distances. (paper)

  13. Polychromatic diffraction contrast tomography

    International Nuclear Information System (INIS)

    King, A.; Reischig, P.; Adrien, J.; Peetermans, S.; Ludwig, W.

    2014-01-01

    This tutorial review introduces the use of polychromatic radiation for 3D grain mapping using X-ray diffraction contrast tomography. The objective is to produce a 3D map of the grain shapes and orientations within a bulk, millimeter-sized polycrystalline sample. The use of polychromatic radiation enables the standard synchrotron X-ray technique to be applied in a wider range of contexts: 1) Using laboratory X-ray sources allows a much wider application of the diffraction contrast tomography technique. 2) Neutron sources allow large samples, or samples containing high Z elements to be studied. 3) Applied to synchrotron sources, smaller samples may be treated, or faster measurements may be possible. Challenges and particularities in the data acquisition and processing, and the limitations of the different variants, are discussed. - Highlights: • We present a tutorial review of polychromatic diffraction contrast tomography techniques. • The use of polychromatic radiation allows the standard synchrotron DCT technique to be extended to a range of other sources. • The characteristics and limitations of all variants of the techniques are derived, discussed and compared. • Examples using laboratory X-ray and cold neutron radiation are presented. • Suggestions for the future development of these techniques are presented

  14. Anisotropic contrast optical microscope.

    Science.gov (United States)

    Peev, D; Hofmann, T; Kananizadeh, N; Beeram, S; Rodriguez, E; Wimer, S; Rodenhausen, K B; Herzinger, C M; Kasputis, T; Pfaunmiller, E; Nguyen, A; Korlacki, R; Pannier, A; Li, Y; Schubert, E; Hage, D; Schubert, M

    2016-11-01

    An optical microscope is described that reveals contrast in the Mueller matrix images of a thin, transparent, or semi-transparent specimen located within an anisotropic object plane (anisotropic filter). The specimen changes the anisotropy of the filter and thereby produces contrast within the Mueller matrix images. Here we use an anisotropic filter composed of a semi-transparent, nanostructured thin film with sub-wavelength thickness placed within the object plane. The sample is illuminated as in common optical microscopy but the light is modulated in its polarization using combinations of linear polarizers and phase plate (compensator) to control and analyze the state of polarization. Direct generalized ellipsometry data analysis approaches permit extraction of fundamental Mueller matrix object plane images dispensing with the need of Fourier expansion methods. Generalized ellipsometry model approaches are used for quantitative image analyses. These images are obtained from sets of multiple images obtained under various polarizer, analyzer, and compensator settings. Up to 16 independent Mueller matrix images can be obtained, while our current setup is limited to 11 images normalized by the unpolarized intensity. We demonstrate the anisotropic contrast optical microscope by measuring lithographically defined micro-patterned anisotropic filters, and we quantify the adsorption of an organic self-assembled monolayer film onto the anisotropic filter. Comparison with an isotropic glass slide demonstrates the image enhancement obtained by our method over microscopy without the use of an anisotropic filter. In our current instrument, we estimate the limit of detection for organic volumetric mass within the object plane of ≈49 fg within ≈7 × 7 μm 2 object surface area. Compared to a quartz crystal microbalance with dissipation instrumentation, where contemporary limits require a total load of ≈500 pg for detection, the instrumentation demonstrated here improves

  15. Determination of contrast media administration to achieve a targeted contrast enhancement in CT

    Science.gov (United States)

    Sahbaee, Pooyan; Li, Yuan; Segars, Paul; Marin, Daniele; Nelson, Rendon; Samei, Ehsan

    2015-03-01

    Contrast enhancement is a key component of CT imaging and offer opportunities for optimization. The design and optimization of new techniques however requires orchestration with the scan parameters and further a methodology to relate contrast enhancement and injection function. In this study, we used such a methodology to develop a method, analytical inverse method, to predict the required injection function to achieve a desired contrast enhancement in a given organ by incorporation of a physiologically based compartmental model. The method was evaluated across 32 different target contrast enhancement functions for aorta, kidney, stomach, small intestine, and liver. The results exhibited that the analytical inverse method offers accurate performance with error in the range of 10% deviation between the predicted and desired organ enhancement curves. However, this method is incapable of predicting the injection function based on the liver enhancement. The findings of this study can be useful in optimizing contrast medium injection function as well as the scan timing to provide more consistency in the way that the contrast enhanced CT examinations are performed. To our knowledge, this work is one of the first attempts to predict the contrast material injection function for a desired organ enhancement curve.

  16. Iodine-based contrast media, multiple myeloma and monoclonal gammopathies: literature review and ESUR Contrast Media Safety Committee guidelines.

    Science.gov (United States)

    Stacul, Fulvio; Bertolotto, Michele; Thomsen, Henrik S; Pozzato, Gabriele; Ugolini, Donatella; Bellin, Marie-France; Bongartz, Georg; Clement, Olivier; Heinz-Peer, Gertraud; van der Molen, Aart; Reimer, Peter; Webb, Judith A W

    2018-02-01

    Many radiologists and clinicians still consider multiple myeloma (MM) and monoclonal gammopathies (MG) a contraindication for using iodine-based contrast media. The ESUR Contrast Media Safety Committee performed a systematic review of the incidence of post-contrast acute kidney injury (PC-AKI) in these patients. A systematic search in Medline and Scopus databases was performed for renal function deterioration studies in patients with MM or MG following administration of iodine-based contrast media. Data collection and analysis were performed according to the PRISMA statement 2009. Eligibility criteria and methods of analysis were specified in advance. Cohort and case-control studies reporting changes in renal function were included. Thirteen studies were selected that reported 824 iodine-based contrast medium administrations in 642 patients with MM or MG, in which 12 unconfounded cases of PC-AKI were found (1.6 %). The majority of patients had intravenous urography with high osmolality ionic contrast media after preparatory dehydration and purgation. MM and MG alone are not risk factors for PC-AKI. However, the risk of PC-AKI may become significant in dehydrated patients with impaired renal function. Hypercalcaemia may increase the risk of kidney damage, and should be corrected before contrast medium administration. Assessment for Bence-Jones proteinuria is not necessary. • Monoclonal gammopathies including multiple myeloma are a large spectrum of disorders. • In monoclonal gammopathy with normal renal function, PC-AKI risk is not increased. • Renal function is often reduced in myeloma, increasing the risk of PC-AKI. • Correction of hypercalcaemia is necessary in myeloma before iodine-based contrast medium administration. • Bence-Jones proteinuria assessment in myeloma is unnecessary before iodine-based contrast medium administration.

  17. Systems and methods for separating particles utilizing engineered acoustic contrast capture particles

    Energy Technology Data Exchange (ETDEWEB)

    Kaduchak, Gregory; Ward, Michael D.

    2018-03-06

    An apparatus for separating particles from a medium includes a capillary defining a flow path therein that is in fluid communication with a medium source. The medium source includes engineered acoustic contrast capture particle having a predetermined acoustic contrast. The apparatus includes a vibration generator that is operable to produce at least one acoustic field within the flow path. The acoustic field produces a force potential minima for positive acoustic contrast particles and a force potential minima for negative acoustic contrast particles in the flow path and drives the engineered acoustic contrast capture particles to either the force potential minima for positive acoustic contrast particles or the force potential minima for negative acoustic contrast particles.

  18. Contrast Agent in Magnetic Resonance Imaging

    DEFF Research Database (Denmark)

    Vu-Quang, Hieu

    2015-01-01

    cancer cells for cancer diagnosis in MRI. F127-Folate coated SPION were stable in various types of suspension medium for over six months. They could specifically target folate receptor of cancer cells in vitro and in vivo thus enhancing the contrast in MRI T2/T2* weighted images. These are preliminary...... for chemotherapy. The nanoparticles were 150 nm in size with spherical shape, which contained PFOB in the inner core and Dox and ICG in the polymeric shell. More importantly, they could target folate receptor expressing cancer cells, which provide positive in vitro and in vivo NIR and 19F MRI results. In project...

  19. Improvements in gastric diagnosis by using high density contrast media with low viscosity

    International Nuclear Information System (INIS)

    Toischer, H.P.

    1983-01-01

    In a retrospective clinical study, 150 unselected double contrast examinations of the stomach using conventional contrast media (100 g/100 ml barium sulphate) were compared with a similar number of examinations using a high density contrast medium of flow viscosity (250 g/100 ml barium sulphate). The high density contrast medium was distinctly better for demonstrating detail of the gastric mucosa. The uneveness of coating and instability of the older high density contrast media was observed in 15.5% of cases and, in no instance, did this make it impossible to reach a diagnosis. (orig.) [de

  20. Alterations of serum potassium, serum magnesium and adenosine diphosphate due to various contrast media containing iodine

    International Nuclear Information System (INIS)

    Lehrberger, G.

    1979-01-01

    As an introduction of the chemical structure of contrast media is explained. Then follows a survey about the complication rates in examinations with intravascularly applicable iodine-containing contrast media. In the next part clinical symptoms and signs of general and localized contrast media incompatibility reactions, the contrast medium protein reaction and the relationship between allergic reaction and contrast medium are explained. It was tried to attribute the large amount of side-effects to one primary reaction. In this connection the three above-mentioned components were investigated. (orig./MG) [de

  1. Contrast Invariant SNR

    DEFF Research Database (Denmark)

    Weiss, Pierre; Escande, Paul; Dong, Yiqiu

    We design an image quality measure independent of local contrast changes, which constitute simple models of illumination changes. Given two images, the algorithm provides the image closest to the first one with the component tree of the second. This problem can be cast as a specific convex progra...... algorithms based on interior point methods. The algorithm has potential applications in change detection, color image processing or image fusion. A Matlab implementation is available at http://www.math.univ-toulouse.fr/_weiss/PageCodes.html.......We design an image quality measure independent of local contrast changes, which constitute simple models of illumination changes. Given two images, the algorithm provides the image closest to the first one with the component tree of the second. This problem can be cast as a specific convex program...... called isotonic regression. We provide a few analytic properties of the solutions to this problem. We also design a tailored first order optimization procedure together with a full complexity analysis. The proposed method turns out to be practically more efficient and reliable than the best existing...

  2. Pharmacodynamics and tolerance of X-ray contrast media

    International Nuclear Information System (INIS)

    Schmiedel, E.

    1987-01-01

    The improved tolerance of nonionic contrast media compared with conventional contrast media is mainly due to their lower osmolality and reduced allergoid potential. Tolerance advantages that have been definitely proven are, for example, low-pain contrast medium injection and superior systemic tolerance; side effects of an allergic pattern occur less often. Animals experiments have established that nonionic contrast media exercise a comparatively lower influence on the cardiovascular system. The haemodynamics of pulmonary circulation are less adversely affected on intravenous bolus injection. Reduced potential risk is to be expected especially in cardiac and bronchopulmonary high-risk patients. The reduced nephrotoxicity of nonionic contrast media was definitely established by clinical studies. Further systematic studies will however be required to provide an answer to the question whether this also entails a reduction in the incidence of renal failures induced by contrast media. (orig.) [de

  3. Effects of radiographic contrast media on the serum complement system

    International Nuclear Information System (INIS)

    Tirone, P.; Boldrini, E.

    1983-01-01

    The authors explored the activation of the complement system produced by a nonionic organic iodine compound, namely iopamidol, which is proposed as a contrast medium for radiographic examination by intravenous and intra-arterial injection. The study was conducted in vitro versus established ionic contrasts (diatrizoate, iothalamate, acetrizoate) and a nonionic compound (metrizamide). The adopted experimental model was the immunohemolytic detector system, in which the immune complex consisted of goat erythrocytes sensitized with the corresponding antibody (hemolysin), and complement (C') was supplied by guinea pig serum. All the products caused complement activation. The results show that nonionic contrast media produce less activation of the complement system than the traditional ionic contrast. Thus the use of nonionic contrast for radiological procedures necessitating the introduction of contrast material into the blood compartment would imply a reduced risk of anaphylactoid reactions. (orig.)

  4. A method for the investigation of cholegraphic contrast media

    International Nuclear Information System (INIS)

    Otto, H.

    1982-01-01

    Isolated perfused rat livers were used for investigating possible interactions between two simultaneously injected contrast media, and which technique, using parenteral application of cholegraphic media, is optimal. The results show that excretion of a parenteral contrast medium is reduced by giving an oral contrast medium at the same time. Simultaneous administration of two different contrast media therefore does not result in improved diagnostic information. The effect depends on the dose, and a sufficiently long interval should be observed between giving an oral and a parenteral contrast medium. A comparison of excretion values following injection of a bolus and prolonged infusion shows higher biliary contrast concentration and increased excretion after a single injection. Comparing only the period after the infusion, no difference was found between these two methods of administration. The single injection offers pharmacokinetic advantages, but an infusion is better tolerated and has fewer side effects. A rapid infusion of 10 to 15 minutes is therefore recommended as the optimal means of administration. (orig.) [de

  5. New MR contrast agent

    International Nuclear Information System (INIS)

    Grossman, C.D.; Subramanian, G.; Schneider, R.; Szeverenyi, N.E.; Rosenbaum, A.M.; Gagne, G.; Tillapaugh-Fay, G.; Berlin, R.; Ritter-Hrncirik, C.; Yu, S.

    1990-01-01

    This paper evaluates an MR contrast agent-meglumine tris-(2,6-dicarboxypyridine) gadolinium (III) or gadolinium dipicolinate (Gd-DPC)-produced in-house. Rats were anesthetized with pentobarbital. For renal imaging, bowel motion artifact was minimized with glucagon (0.014 mg/kg, intravenous (IV)). Enhanced images were generated on a 2-T chemical shift imaging system with a 31-cm horizontal bore magnet after IV injection of Gd-DPC (100 μM/kg). Coronal sections of the kidneys and sagittal sections of the brain, 2 mm thick, were made. Six to eight excitations and 128 or 356 phase-encoding steps were used for each image. Control animals were injected with equivalent doses of gadopentetate dimeglumine

  6. Contrast enhancement of mail piece images

    Science.gov (United States)

    Shin, Yong-Chul; Sridhar, Ramalingam; Demjanenko, Victor; Palumbo, Paul W.; Hull, Jonathan J.

    1992-08-01

    A New approach to contrast enhancement of mail piece images is presented. The contrast enhancement is used as a preprocessing step in the real-time address block location (RT-ABL) system. The RT-ABL system processes a stream of mail piece images and locates destination address blocks. Most of the mail pieces (classified into letters) show high contrast between background and foreground. As an extreme case, however, the seasonal greeting cards usually use colored envelopes which results in reduced contrast osured by an error rate by using a linear distributed associative memory (DAM). The DAM is trained to recognize the spectra of three classes of images: with high, medium, and low OCR error rates. The DAM is not forced to make a classification every time. It is allowed to reject as unknown a spectrum presented that does not closely resemble any that has been stored in the DAM. The DAM was fairly accurate with noisy images but conservative (i.e., rejected several text images as unknowns) when there was little ground and foreground degradations without affecting the nondegraded images. This approach provides local enhancement which adapts to local features. In order to simplify the computation of A and (sigma) , dynamic programming technique is used. Implementation details, performance, and the results on test images are presented in this paper.

  7. Contrast media for radiological examination in gastrointestinal tract leakage

    NARCIS (Netherlands)

    A.Z. Ginai (Abida)

    1987-01-01

    textabstractThe aim of this investigation has been to find a safe and suitable contrast medium for radiological evaluation of the gastrointestinal tract in cases where leakage outside the GIT can be suspected. Leakage outside the gastro-intestinal tract lumen can occur in many ways eg.,

  8. Ameliorative effect of green tea against contrast-induced renal tubular cell injury.

    Science.gov (United States)

    Nasri, Hamid; Hajian, Shabnam; Ahmadi, Ali; Baradaran, Azar; Kohi, Golnoosh; Nasri, Parto; Rafieian-Kopaei, Mahmoud

    2015-11-01

    Reactive oxygen species are a mediator of kidney damage by contrast media, and green tea is a potent-free radical scavenger. This study was designed to examine whether green tea could protect against the nephrotoxicity induced by contrast media. Forty rats were randomly divided into 4 groups. Group 1 was control; group 2 received contrast medium (intravenous iodixanol, 10 mL/kg, as a single dose); group 3 received contrast medium and then green tea extract for 3 days (10 mg/kg/d, intraperitoneal); and group 4 first received green tea and then contrast medium. Histological changes (degeneration, vacuolization of tubular renal cells, dilatation of tubular lumen, and presence of debris in the lumens) were assessed and recorded as scores from zero to 4. The sum of scores were used as the overal renal injury level. Groups 3 and 4 with green tea treatment had significantly higher overall scores than the control group, but significantly lower scores than group 2 with contrast medium only. A similar trend was seen for dilatation and degeneration levels. Vacuolization level was not significantly lower in the green tea groups as compared to the contrast medium group. Debris level was not significantly lower in group 3 than group 2. The differences were not significant between groups 3 and 4.   Conclusions. We observed beneficial effect of green tea against nephrotoxicity of contrast media. Green tea extract may offer an inexpensive and nontoxic intervention strategy in patients with a risk for nephrotoxicity with contrast media.

  9. Contrast media induced acute renal failure in diabetics

    International Nuclear Information System (INIS)

    Rambausek, M.

    1985-01-01

    Dehydration, preexisting renal insufficiency, multiple myeloma and insulin-dependent diabetes mellitus are known risk factors for a radiocontrast medium induced acute renal failure. In 90% of patients with insulin-dependent diabetes mellitus, renal insufficiency and proteinuria, a further detoriation of renal function can be expected after i.v. administration of radiocontrast medium. Recent concepts on the genesis of acute renal failure after radiocontrast medium in multiple myeloma emphasize the role of tubular blocade (tubular precipitation of myeloma protein with contrast medium). In insulin-dependent diabetic patients we found altered carbohydrate composition of urinary Tamm Horsfall Protein (THP), with increased glucose and diminished N-acetyl-neuraminicacid content. This was paralleled by a difference in an in-vitro system of coprecipitation where THP of diabetes triggered more pronounced calcium dependent coprecipitation of contrast medium and albumin. These in-vitro findings might be important for the explanation of the genesis of radiocontrast medium-induced acute renal failure in insulin-dependent diabetes mellitus. (orig.) [de

  10. The interaction of radiographic contrast media with immune globulins

    International Nuclear Information System (INIS)

    Bauer, K.

    1983-01-01

    As a special form of contrast medium incidents, various reaction modes between iodinated contrast media and immunoglobulins are described. Theoretical explanations and typical examples are given for each of the four different possible action mechanisms. Diagnostic precautions are proposed in order to avoid unfavourable reactions especially with paraproteins. Special attention is drawn to the antigen-antibody like reaction between iodinated contrast media and IgM paraproteins. Some immunological criteria are recalled to attention, this type of reaction has to meet stringently. Only by this, misinterpretations of inevident conclusions from analogy can be prevented in future similar cases. (orig.) [de

  11. Comparative study of pneumocystography, positive contrast cystography and double contrast cystography in dogs

    International Nuclear Information System (INIS)

    Thibaut, J.; Parada, E.; Vargas, L.; Deppe, R.; Born, R.

    1997-01-01

    In order to compare three radiographic techniques: pneumocystography, positive contrast cystography and double contrast cystography, three series of 24 radiographs each in lateral and ventrodorsal projections were made. Six healthy adult male dogs with weight ranging between 7 and 16 kg were used. Food was withheld for 24 hours and two enemas were made before the series of radiographs were taken. Dogs were anaesthetized with sodium thiopental (20 mg/kg i.v.). The contrast medium was introduced through a urethral catheter. Pneumocystography was performed in the first series introducing air (10 ml/kg) in the bladder. Positive contrast cystography was performed in the second series introducing Hypaque M-60% diluted, contributing 100 mg of iodine per ml (10 ml/kg). In the double contrast cystography Hypaque M-60% diluted (10 ml) was introduced, in concentration of 150 mg of iodine per ml. Then air was introduced (10 ml/kg) through a catheter. Plates were taken in both projections at 1 and 10 minutes for each technique. The radiographic plates of each series were analized comparing the characteristics of radiographic density, outline and size. In neumocystography, positive contrast and double contrast cystography, the radiographic density was predominantly low, high and intermediate, respectively. The radiographic outline was mainly regular for the three techniques. With respect to bladder size, there was a decrease of height and an increase of length and width at 10 minutes. Comparing these three radiographic techniques, it can be concluded that the one that best outlines the bladder mucosa is double contrast. Pneumocystography provides the best image for opaque structures and cystography best shows the position of the urinary bladder [es

  12. MR mammography: influence of menstrual cycle on the dynamic contrast enhancement of fibrocystic disease

    Energy Technology Data Exchange (ETDEWEB)

    Rieber, A.; Nuessle, K.; Merkle, E.; Tomczak, R.; Brambs, H.J. [Ulm Univ. (Germany). Abt. Radiologie 1 (Roentgendiagnostik); Kreienberg, R. [Ulm Univ. (Germany). Dept. of Gynecology

    1999-08-01

    Magnetic resonance mammography (MRM) provides data regarding the nature of tumours based on contrast medium dynamics; fibrocystic changes in the breast, however, may lead to false-positive results. This study investigated whether the contrast medium dynamics of fibrocystic changes are dependent on the menstrual cycle. Twenty-four patients with palpable lumps but normal mammographies and ultrasound studies were examined. The MRM technique was performed during the first and second part of the menstrual cycle using a FLASH 3D sequence, both native and at 1, 2, 3 and 8 min after intravenous application of 0.15 mmol/kg body weight of gadodiamide. The calculated time-intensity curves were evaluated based on the following criteria: early percentage of contrast medium uptake in relation to the native value; formation of a plateau phenomenon after the second minute; the point of maximal contrast medium uptake; and calculation of the contrast enhancing index. During the second half of the menstrual cycle, a generally greater contrast medium uptake was observed. Nevertheless, when further diagnostic criteria, such as continuous contrast medium increase as a function of time, were considered, there was no increased rate of false-positive findings. The phase of the menstrual cycle may affect the specificity of the examination, if only the quantitative contrast medium uptake and the percentage of contrast medium uptake in the first 2 min are considered. A control MRM during the other half of the cycle may then be indicated and additional diagnostic criteria may improve specificity. (orig.) With 2 figs., 2 tabs., 24 refs.

  13. Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Menk, Ralf Hendrik

    2008-01-01

    All standard (medical) x-ray imaging technologies, rely primarily on the amplitude properties of the incident radiation, and do not depend on its phase. This is unchanged since the discovery by Roentgen that the intensity of an x-ray beam, as measured by the exposure on a film, was related to the relative transmission properties of an object. However, recently various imaging techniques have emerged which depend on the phase of the x-rays as well as the amplitude. Phase becomes important when the beam is coherent and the imaging system is sensitive to interference phenomena. Significant new advances have been made in coherent optic theory and techniques, which now promise phase information in medical imaging. The development of perfect crystal optics and the increasing availability of synchrotron radiation facilities have contributed to a significant increase in the application of phase based imaging in materials and life sciences. Unique source characteristics such as high intensity, monochromaticity, coherence and high collimating provide an ideal source for advanced imaging. Phase contrast imaging has been applied in both projection and computed tomography modes, and recent applications have been made in the field of medical imaging. Due to the underlying principle of X-ray detection conventional image receptors register only intensities of wave fields and not their phases. During the last decade basically five different methods were developed that translate the phase information into intensity variations. These methods are based on measuring the phase shift φ directly (using interference phenomena), the gradient ∇ φ , or the Laplacian ∇ 2 φ. All three methods can be applied to polychromatic X-ray sources keeping in mind that the native source is synchrotron radiation, featuring monochromatic and reasonable coherent X-ray beams. Due to the vast difference in the coefficients that are driven absorption and phase effects (factor 1,000-10,000 in the energy

  14. Double contrast gastrography in dogs.

    Science.gov (United States)

    Kumar, R; Peshin, P K; Nigam, J M

    1981-09-01

    For experimental evaluation of double contrast gastrography in 9 dogs, sodium iothalamate and air were used for positive and negative contrast, respectively, to delineate the gastric mucosa. The technic was simple and reasonably safe. Results were satisfactory when the stomach was empty, and appropriate volumes of contrast materials were evenly distributed.

  15. Pions in the nuclear medium

    International Nuclear Information System (INIS)

    Chanfray, G.

    1996-07-01

    We discuss various aspects of pion physics in the nuclear medium. We first study s-wave pion-nucleus interaction in connection with chiral symmetry restoration and quark condensate in the nuclear medium. We then address the question of p-wave pion-nucleus interaction and collective pionic modes in nuclei and draw the consequences for in medium ππ correlations especially in the scalar-isoscalar channel. We finally discuss the modification of the rho meson mass spectrum at finite density and/or temperature in connection with relativistic heavy ion collisions

  16. Physical experiments on the utility of non-iodine-containing contrast media

    International Nuclear Information System (INIS)

    Kirschner, H.; Burmester, U.; Stringaris, K.; Jentsch, F.

    1979-01-01

    Because of the excellent ability of the CT scanner in analyzing absorption, the use of non-iodine-containing contrast media will be discussed. Experimental studies of the chemical elements with the atomic number Z = 1-83 with a scan tension of 120 kV were made to determine how many atoms of a given element are necessary to replace one iodine atom in an iodine-containing contrast medium, whereby the same contrast enhancement in the scan picture as with the iodine-containing contrast medium is produced. (orig.) 891 ORU/orig. 892 MB [de

  17. Organizational liability for adverse reactions to the contrast media

    International Nuclear Information System (INIS)

    Lim, Chang Seon

    2007-01-01

    Contrast medium is a very useful tool for X-ray examinations. But contrast medium has some unavoidable adverse reactions. For those patients who have never received contrast medium before, it is impossible to predict whether they will suffer from certain kinds of adverse reactions. Thus, radiologists should use strategies to minimize adverse events and be prepared to promptly recognize and manage any reactions to the contrast media. If a radiologist commits medical malpractice, he will face civil responsibility. Medical malpractice means a tort or breach of contrast that occurs in a medical setting. Medical malpractices happen, despite the efforts of hospital staff. Many courts have applied the traditional doctrine of respondeat superior in actions against organizations for injuries caused by their employees. It is a legal doctrine, which states that an employer is responsible for employee actions performed within the course of the employment. A hospital is an organization for health purposes. An organization may be convicted of an offense committed by an employee of the organization acting in its behalf and within the scope of this office or employment. Organizational liability involves a wide variety of legal issues, including tort liability, wrongful employment practices, personal injury, breach of fiduciary duty, and so on. Many executive directors of organizations are aware of their personal and organizational risks of exposure to legal liabilities. The employer must have the right to control the physical conduct of the employee and must consent to receive the employee's services, while expecting some benefits from the services offered. Therefore, legal liability can be imposed for improper selection, assignment, training, and supervision of employees. In conclusion, the hospital itself has organizational liability for adverse reactions to the contrast medium

  18. Organizational liability for adverse reactions to the contrast media

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Chang Seon [Konyang University, Daejeon (Korea, Republic of)

    2007-06-15

    Contrast medium is a very useful tool for X-ray examinations. But contrast medium has some unavoidable adverse reactions. For those patients who have never received contrast medium before, it is impossible to predict whether they will suffer from certain kinds of adverse reactions. Thus, radiologists should use strategies to minimize adverse events and be prepared to promptly recognize and manage any reactions to the contrast media. If a radiologist commits medical malpractice, he will face civil responsibility. Medical malpractice means a tort or breach of contrast that occurs in a medical setting. Medical malpractices happen, despite the efforts of hospital staff. Many courts have applied the traditional doctrine of respondeat superior in actions against organizations for injuries caused by their employees. It is a legal doctrine, which states that an employer is responsible for employee actions performed within the course of the employment. A hospital is an organization for health purposes. An organization may be convicted of an offense committed by an employee of the organization acting in its behalf and within the scope of this office or employment. Organizational liability involves a wide variety of legal issues, including tort liability, wrongful employment practices, personal injury, breach of fiduciary duty, and so on. Many executive directors of organizations are aware of their personal and organizational risks of exposure to legal liabilities. The employer must have the right to control the physical conduct of the employee and must consent to receive the employee's services, while expecting some benefits from the services offered. Therefore, legal liability can be imposed for improper selection, assignment, training, and supervision of employees. In conclusion, the hospital itself has organizational liability for adverse reactions to the contrast medium.

  19. Post double-contrast sigmoid flush: An adjuvant technique in imaging diverticular disease

    International Nuclear Information System (INIS)

    Lappas, J.C.; Maglinte, D.D.T.; Kopecky, K.K.; Cockerill, E.M.; Lehman, G.A.

    1987-01-01

    In a prospective study, the effect of a low-density contrast medium infusion was evaluated as an adjunct to high-density double-contrast medium sigmoid imaging. Following a double-contrast medium barium enema (DCBE), 52 consecutive patients with sigmoid diverticulosis received an additional 500-700-mL enema with either water or a 1.5%CT barium suspension. Rectosigmoid films were evaluated for luminal distention, visualization of the interhaustral space, definition of diverticula, and interpretation of polypoid defects. While double-contrast medium views were excellent in 21%, improvement in multiple factors by water or 1.5% barium flush resulted in improved sigmoid images in 65% and 73% of patients, respectively. Polyps may be confirmed and artifactual defects confidently excluded. Sigmoid flush, particularly with low-density barium, is a simple adjunct to DCBE that improves visualization of the diverticular sigmoid

  20. Contrast bolus technique with rapid CT scanning

    International Nuclear Information System (INIS)

    Arnold, H.; Kuehne, D.; Rohr, W.; Heller, M.

    1981-01-01

    Twenty-three patients complying with the clinical criteria for brain death were studied by contrast-enhanced CT. In all but one, the great intracranial vessels escaped visualization; accordingly, angiography demonstrated cerebral circulatory arrest. In the remaining case, faint enhancement of the circle of Willis corresponded to angiographic demonstration of the proximal segments of cerebral arteris. Neither in normal brain nor in dead brain did slow CT scanning disclose any postcontrast increase in parenchymal attenuation. An improved technique is proposed to demonstrate the transit of the contrast bolus by rapid CT with image splitting. If cerebral blood flow is preserved, the grey and white matter will enhance significantly following administration of contrast medium. Vice versa, the absence of enhancement confirms brain death, even in instances in which the great cerebral vessels are obscured by hemorrhage or other extensive lesions. Two additional cases of brain death were evaluated by rapid CT scanning. As to brain death, the technique obviates the need for angiography or radionuclide angiography, usually applied in prospective organ donors, because its informative content is superior to that of either method. The CT technique described affords a reliable and safe diagnosis of brain death, and can be interpreted easily. (orig.)

  1. Differential Medium for Vibrio cholerae

    Science.gov (United States)

    Schrank, Gordon D.; Stager, Charles E.; Verwey, W. F.

    1973-01-01

    A differential medium designed for rapid presumptive identification of Vibrio cholerae was described and shown to be useful for enumeration of viable cholera vibrios in the presence of other intestinal bacteria. Images PMID:4764406

  2. The Value of Contrast Echocardiography

    Directory of Open Access Journals (Sweden)

    Shannon C. Treiber

    2016-01-01

    Full Text Available Purpose: There is much evidence-based research proving the effectiveness of contrast echocardiography, but there are still questions and concerns about its specific uses. This study tested the effectiveness of contrast echocardiography in defining the left ventricular endocardial border. Methods: From 30 patients, a total of 60 echocardiograms –– 30 with and 30 without use of contrast –– were retrospectively reviewed by four blinded cardiologists with advanced training in echocardiography. No single cardiologist reviewed contrast and noncontrast images of the same patient. Each set of 30 echocardiograms was then studied for wall-motion scoring. Visualization of left ventricular wall segments and a global visualization confidence level of interpretation were recorded. Results: Of all wall segments (N = 510, 91% were visualized in echocardiograms with use of contrast, whereas 75% of the walls were visualized in echocardiograms without contrast (P < 0.001. Of 30 examinations, 17 contrast echocardiograms were read with high confidence compared to 6 without contrast use (P = 0.004. The number of walls visualized with contrast was increased in 18 patients (60%, whereas noncontrast echocardiograms yielded more visualized walls in 6 patients (20%, P = 0.002. Conclusions: This study demonstrates that contrast is valuable to echocardiographic imaging. Its use should be supported throughout echocardiography clinics and encouraged in certain patients for whom resting and stress echocardiography results without contrast often prove uninterpretable.

  3. Medium effects in direct reactions

    International Nuclear Information System (INIS)

    Karakoc, M; Bertulani, C

    2013-01-01

    We discuss medium corrections of the nucleon-nucleon (NN) cross sections and their influence on direct reactions at intermediate energies ≳50 MeV/nucleon. The results obtained with free NN cross sections are compared with those obtained with a geometrical treatment of Pauli-blocking and Dirac-Bruecker methods. We show that medium corrections may lead to sizable modifications for collisions at intermediate energies and that they are more pronounced in reactions involving weakly bound nuclei.

  4. Homogenization of High-Contrast Brinkman Flows

    KAUST Repository

    Brown, Donald L.

    2015-04-16

    Modeling porous flow in complex media is a challenging problem. Not only is the problem inherently multiscale but, due to high contrast in permeability values, flow velocities may differ greatly throughout the medium. To avoid complicated interface conditions, the Brinkman model is often used for such flows [O. Iliev, R. Lazarov, and J. Willems, Multiscale Model. Simul., 9 (2011), pp. 1350--1372]. Instead of permeability variations and contrast being contained in the geometric media structure, this information is contained in a highly varying and high-contrast coefficient. In this work, we present two main contributions. First, we develop a novel homogenization procedure for the high-contrast Brinkman equations by constructing correctors and carefully estimating the residuals. Understanding the relationship between scales and contrast values is critical to obtaining useful estimates. Therefore, standard convergence-based homogenization techniques [G. A. Chechkin, A. L. Piatniski, and A. S. Shamev, Homogenization: Methods and Applications, Transl. Math. Monogr. 234, American Mathematical Society, Providence, RI, 2007, G. Allaire, SIAM J. Math. Anal., 23 (1992), pp. 1482--1518], although a powerful tool, are not applicable here. Our second point is that the Brinkman equations, in certain scaling regimes, are invariant under homogenization. Unlike in the case of Stokes-to-Darcy homogenization [D. Brown, P. Popov, and Y. Efendiev, GEM Int. J. Geomath., 2 (2011), pp. 281--305, E. Marusic-Paloka and A. Mikelic, Boll. Un. Mat. Ital. A (7), 10 (1996), pp. 661--671], the results presented here under certain velocity regimes yield a Brinkman-to-Brinkman upscaling that allows using a single software platform to compute on both microscales and macroscales. In this paper, we discuss the homogenized Brinkman equations. We derive auxiliary cell problems to build correctors and calculate effective coefficients for certain velocity regimes. Due to the boundary effects, we construct

  5. Quality of roentgenological visualization and tolerance of various intravenous cholegraphic contrast media

    International Nuclear Information System (INIS)

    Tischendorf, P.

    1980-01-01

    The recently introduced intravenous cholegraphic contrast media produce a greater diagnostic yield in radiological routine thanks to improved roentgenological contrasting. Whereas the percentage share of roentgenologically clearly assessable cases is about 75% when using Biligrafin, this percentage is much higher with the more recent contrast media, especially Biliscopin, namely, up to 88%. These new contrast media are also superior in respect of tolerance, since they produce fewer side effects. While side effects must be expected in about 28% of the cases when injecting Biligrafin, the side effect quota is about 10% only with Biliscopin or Endomirabil. If the contrast medium is infused instead of injected, the quota of side effect drops to 2.3% with Biliscopin or 3.9% with Endomirabil. Slight and medium side effects have definitely decreased with the more recent contrast media. The slower and more continually the contrast medium is administered, the fewer are the side effects observed; this becomes particularly noticeable in the case of long-term infusions. However, the likelihood of severe incidents caused by the contrast medium remains unchanged at about 1% of the examined patients, even with the more recently introduced contrast media. (orig.) [de

  6. Gadolinium-enhanced magnetic resonance angiography for hepato mesenteric vascular evaluation: single and double doses comparison in schistosomiasis patients; Estudo da circulacao hepatomesenterica pela angiografia por ressonancia magnetica com gadolinio: comparacao entre doses simples e dupla no estudo de pacientes esquistossomoticos

    Energy Technology Data Exchange (ETDEWEB)

    Caldana, Rogerio Pedreschi; Bezerra, Alexandre Sergio de Araujo; D' Ippolito, Giuseppe; Szejnfeld, Jacob [Universidade Federal de Sao Paulo (UNIFESP/EPM), SP (Brazil). Dept. de Diagnostico por Imagem]. E-mail: rogercal@uol.com.br

    2006-07-15

    Objective: to evaluate the visibility of hepatomesenteric vascular segments by 3D gadolinium-enhanced magnetic resonance (MR) angiography and to compare the method effectiveness between two different gadolinium doses (single and double doses). Materials and methods: a prospective study was performed with 36 schistosomiasis patients who were submitted to 3D contrast-enhanced MR angiography. Scans were performed in a high-field equipment (1.5 T), with body coil and power injector for intravenous contrast administration. Contrast double doses (Gd-DTPA 0.2 mmol/kg) and single doses (0.1 mmol/kg) were randomly used respectively in 21 and 15 patients. Studies were interpreted by consensus between two observers who have rated the visualization degree of 25 proximal vascular segments without knowing the dose used. Results: proximal and calibrous vascular segments have presented higher visualization degree in the greatest part of the sample studied. The celiac trunk, common hepatic artery, splenic artery, proximal and medium third of superior mesenteric artery, portal vein, splenic vein and superior mesenteric vein have presented grade 2 visualization in more than 70% of the sample studied. As regards comparison between different doses, there was no significant difference (p < 0.05) in the visualization degree of several structures evaluated, between double dose and single dose groups, except for an isolate case of evaluation of right hepatic artery (p = 0.008) in which the single dose group has presented a higher frequency of grade 2 visualization with statistical significance. Conclusion: the visualization degree of hepato mesenteric vascular segments by 3D gadolinium-enhanced MR angiography is high, especially in the proximal and calibrous segments. The comparison between groups using single and double contrast doses has demonstrated similar results. (author)

  7. Properties of conventional contrast media

    International Nuclear Information System (INIS)

    Muetzel, W.

    1981-01-01

    A comprehensive overview is given of the properties of contrast media currently used in computed tomography (CT). The chemical structure of the compounds and the physicochemical properties derived therefrom are described. Emphasis is placed on the importance of the physicochemical properties of contrast media for tolerance and the pharmacokinetic behavior of compounds in the body. An outline is given of the basic ideas governing rational use of contrast media in CT, which result from complex, time-dependent distribution of contrast media in different tissue spaces. (Auth.)

  8. Nuclear magnetic resonance contrast agents

    Science.gov (United States)

    Smith, P.H.; Brainard, J.R.; Jarvinen, G.D.; Ryan, R.R.

    1997-12-30

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC{sub 16}H{sub 14}N{sub 6}. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques. 10 figs.

  9. The T2-Shortening Effect of Gadolinium and the Optimal Conditions for Maximizing the CNR for Evaluating the Biliary System: a Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mi Jung; Kim, Myung Joon [Severance Children' s Hospital, Yensei University College of Medicine, Seoul (Korea, Republic of); Yoon, Choon Sik [Gangnam Severance Hospital, Yensei University College of Medicine, Seoul (Korea, Republic of); Song, Si Young [Severance Hospital, Yensei University College of Medicine, Seoul (Korea, Republic of); Park, Kyung Soo [Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Woo Sun [Seoul Nationa University College of Medicine, Seoul (Korea, Republic of)

    2011-06-15

    Clear depiction of the common bile duct is important when evaluating neonatal cholestasis in order to differentiate biliary atresia from other diseases. During MR cholangiopancreatography, the T2-shortening effect of gadolinium can increase the contrast-to-noise ratio (CNR) of the bile duct and enhance its depiction. The purpose of this study was to confirm, by performing a phantom study, the T2-shortening effect of gadolinium, to evaluate the effect of different gadolinium chelates with different gadolinium concentrations and different magnetic field strengths for investigating the optimal combination of these conditions, and for identifying the maximum CNR for the evaluation of the biliary system. MR imaging using a T2-weighted single-shot fast spin echo sequence and T2 relaxometry was performed with a sponge phantom in a syringe tube. Two kinds of contrast agents (Gd-DTPA and Gd-EOB-DTPA) with different gadolinium concentrations were evaluated with 1.5T and 3T scanners. The signal intensities, the CNRs and the T2 relaxation time were analyzed. The signal intensities significantly decreased as the gadolinium concentrations increased (p < 0.001) with both contrast agents. These signal intensities were higher on a 3T (p < 0.001) scanner. The CNRs were higher on a 1.5T (p < 0.001) scanner and they showed no significant change with different gadolinium concentrations. The T2 relaxation time also showed a negative correlation with the gadolinium concentrations (p < 0.001) and the CNRs showed decrease more with Gd-EOB-DTPA (versus Gd-DTPA; p < 0.001) on a 3T scanner (versus 1.5T; p < 0.001). A T2-shortening effect of gadolinium exhibits a negative correlation with the gadolinium concentration for both the signal intensities and the T2 relaxation time. A higher CNR can be obtained with Gd-DTPA on a 1.5T MRI scanner.

  10. Chemistry of the interstellar medium

    International Nuclear Information System (INIS)

    Umanskij, S.Ya.

    1979-01-01

    Some aspects of chemistry of interstellar gas-dust clouds are considered. The specific attention is paid to the molecule formation in the interstellar medium. Discussed are the process of hydrogen atom recombination on interstellar specks of dust as well as the formation of double-atom molecules. An ion-molecular mechanism plays the main role in the origination of multiatom molecules. It is noted, that the real progress in chemistry of the interstellar medium will be determined by the development of laboratory investigations at ultralow temperatures and study of the processes proceeding on solid surfaces

  11. Contrast-enhanced peripheral MRA

    DEFF Research Database (Denmark)

    Nielsen, Yousef W; Thomsen, Henrik S

    2012-01-01

    -state MRA. Gadolinium(Gd)-based contrast agents are used for CE-MRA of the peripheral arteries. Extracellular Gd agents have a pharmacokinetic profile similar to iodinated contrast media. Accordingly, these agents are employed for first-pass MRA. Blood-pool Gd-based agents are characterized by prolonged......In the last decade contrast-enhanced magnetic resonance angiography (CE-MRA) has gained wide acceptance as a valuable tool in the diagnostic work-up of patients with peripheral arterial disease. This review presents current concepts in peripheral CE-MRA with emphasis on MRI technique and contrast...... MRI contrast agent is injected intravenously and T1-weighted images are acquired in the subsequent arterial first-pass phase. In order to achieve high quality MR angiograms without interfering venous contamination or artifacts, a number of factors need to be taken into account. This includes magnetic...

  12. Borel sum rules for octet baryons in nuclear medium

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Y.; Morimatsu, O.

    1992-06-01

    Borel sum rules are examined for octet baryons in the nuclear medium. First, it is noticed that in the medium the dispersion relation is realized for the retarded correlation [Pi][sup R]([omega], q[sup 2]) in the energy [omega]. Then, [Pi][sup R]([omega], q[sup 2]) is split into even and odd parts of [omega] in order to apply the Borel transformation. The obtained Borel sum rules differ from those of previous works. The mass shifts of octet baryons are calculated in the leading order of the operator product expansion with linear density approximation for the condensates. It is found that both scalar and vector condensates of the quark field, and , induce attraction to the octet baryons in the medium in contrast to the results of previous works. It is also found that [delta]M[sub N] > [delta]M[sub [Lambda

  13. Comparison of neutral and positive enteral contrast media for MDCT enteroclysis

    International Nuclear Information System (INIS)

    Aiyappan, Senthil Kumar; Kalra, Naveen; Sandhu, Manavjit Singh; Kochhar, Rakesh; Wig, Jai Dev; Khandelwal, Niranjan

    2012-01-01

    Objective: To compare neutral and positive enteral contrast media for MDCT enteroclysis (MDCTE) in various small bowel diseases. Materials and methods: 40 patients with suspicion of small bowel diseases were divided randomly into two equal groups. In one group, water was used as neutral enteral contrast and in other group, 2% water soluble iodinated contrast was used as positive enteral contrast. All MDCTE were done on a 16-slice multidetector row CT unit. The findings of MDCTE were compared with the standards of reference. Results: There were 12 cases of abdominal tuberculosis (30%), 5 cases of bowel masses (12%), 4 cases of Crohn's disease (10%), 3 cases of small bowel adhesions (7%), 2 cases of midgut volvulus (5%), 2 cases of segmental enteritis (5%) and 12 of all cases (30%) were normal. There was no statistically significant difference between neutral and positive enteral contrast with regards to bowel distention, contrast reflux and evaluation of duodenum. Abnormal bowel wall enhancement was appreciated only with use of neutral enteral contrast (n = 12). Evaluation of ileocaecal junction was possible in all 20 patients (100%) with positive enteral contrast but in only 17 patients (85%) with neutral enteral contrast. Overall sensitivity and specificity of MDCTE with use of neutral contrast medium (100 and 88% respectively) was greater for evaluation of small bowel diseases, when compared to MDCTE using positive enteral contrast medium (92.8 and 83.3% respectively). Conclusions: Water is a good enteral contrast medium for MDCT enteroclysis examination and allows better evaluation of abnormal bowel wall enhancement. Ileocaecal junction evaluation is better with positive enteral contrast medium.

  14. Demonstration of flash K-edge angiography utilizing gadolinium-based contrast medium

    Science.gov (United States)

    Sato, Eiichi; Sagae, Michiaki; Obara, Haruo; Germer, Rudolf; Tanaka, Etsuro; Mori, Hidezo; Kawai, Toshiaki; Ichimaru, Toshio; Sato, Shigehiro; Ojima, Hidenori; Takayama, Kazuhiro; Ido, Hideaki

    2005-03-01

    The high-voltage condensers in a polarity-inversion two-stage Marx surge generator are charged from -50 to -70 kV by a power supply, and the electric charges in the condensers are discharged to an x-ray tube after closing gap switches in the surge generator with a trigger device. The x-ray tube is a demountable diode, and the turbomolecular pump evacuates air from the tube with a pressure of approximately 1 mPa. Tungsten characteristic x rays can be produced, since the tube utilizes a disk cathode and a rod target, and bremsstrahlung rays are not emitted in the opposite direction to that of electron acceleration. At a charging voltage of -70 kV, the instantaneous tube voltage and current were 140 kV and 1.0 kA, respectively. The x-ray pulse widths were approximately 90 ns, and the estimated number of K photons was approximately 5×108 photons/cm2 per pulse at 0.5 m from the source of 3.0 mm in diameter.

  15. Activation of platelets by low-osmolar contrast media: differential effects of ionic and nonionic agents

    NARCIS (Netherlands)

    Hardeman, M. R.; Konijnenberg, A.; Sturk, A.; Reekers, J. A.

    1994-01-01

    To determine the effects of an ionic low-osmolar contrast medium (ioxaglate) and two nonionic low-osmolar contrast media (iohexol and iopamidol) on human platelet activation in vitro. Flow cytometry analysis subsequent to reaction with fluorescence-labeled monoclonal antibodies was used to detect

  16. The use of iodinated and gadolinium contrast media during pregnancy and lactation

    Energy Technology Data Exchange (ETDEWEB)

    Webb, Judith A.W. [St. Bartholomew' s Hospital, Department of Diagnostic Imaging, London (United Kingdom); Thomsen, Henrik S. [Copenhagen University Hospital at Herlev, Department of Diagnostic Radiology 54E2, Herlev (Denmark); Morcos, Sameh K. [Northern General Hospital, Department of Diagnostic Imaging, Sheffield (United Kingdom)

    2005-06-01

    The use of iodinated or gadolinium-based contrast media in pregnant or lactating women often causes concerns in the radiology department because of the principle of not exposing a fetus or neonate to any drugs. Because of the uncertainty about the use of contrast media during pregnancy and lactation, the Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines. An extensive literature search was carried out and summarized in a report. Based on the limited information available, simple guidelines have been drawn up. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. Mutagenic and teratogenic effects have not been described after administration of gadolinium or iodinated contrast media. Free iodide in radiographic contrast medium given to the mother has the potential to depress fetal/neonatal thyroid function. Neonatal thyroid function should be checked during the 1st week if iodinated contrast media have been given during pregnancy. No effect on the fetus has been seen after gadolinium contrast media. Only tiny amounts of iodinated or gadolinium-based contrast medium given to a lactating mother reach the milk, and only a minute proportion entering the baby's gut is absorbed. The very small potential risk associated with absorption of contrast medium may be considered insufficient to warrant stopping breast-feeding for 24 h following either iodinated or gadolinium contrast agents. (orig.)

  17. The use of iodinated and gadolinium contrast media during pregnancy and lactation

    International Nuclear Information System (INIS)

    Webb, Judith A.W.; Thomsen, Henrik S.; Morcos, Sameh K.

    2005-01-01

    The use of iodinated or gadolinium-based contrast media in pregnant or lactating women often causes concerns in the radiology department because of the principle of not exposing a fetus or neonate to any drugs. Because of the uncertainty about the use of contrast media during pregnancy and lactation, the Contrast Media Safety Committee of the European Society of Urogenital Radiology decided to review the literature and draw up guidelines. An extensive literature search was carried out and summarized in a report. Based on the limited information available, simple guidelines have been drawn up. The report and guidelines were discussed at the 11th European Symposium on Urogenital Radiology in Santiago de Compostela, Spain. Mutagenic and teratogenic effects have not been described after administration of gadolinium or iodinated contrast media. Free iodide in radiographic contrast medium given to the mother has the potential to depress fetal/neonatal thyroid function. Neonatal thyroid function should be checked during the 1st week if iodinated contrast media have been given during pregnancy. No effect on the fetus has been seen after gadolinium contrast media. Only tiny amounts of iodinated or gadolinium-based contrast medium given to a lactating mother reach the milk, and only a minute proportion entering the baby's gut is absorbed. The very small potential risk associated with absorption of contrast medium may be considered insufficient to warrant stopping breast-feeding for 24 h following either iodinated or gadolinium contrast agents. (orig.)

  18. Micropropagation of dahlia in static liquid medium using slow-release tools of medium ingredients

    NARCIS (Netherlands)

    Klerk, de G.J.M.; Brugge, ter J.

    2011-01-01

    Growth of dahlia shoots in vitro was ca. 4 times faster in liquid medium than on solidified medium. In liquid standard medium (3% sucrose, macroelements according to Driver–Kuniyuki Walnut medium, microelements according to Murashige–Skoog medium, 0.44 µM benzylaminopurine), the major medium

  19. Use of cystatin C and serum creatinine for the diagnosis of contrast-induced nephropathy in patients undergoing contrast-enhanced computed tomography at an oncology centre.

    Science.gov (United States)

    Fortalesa Melo, Joao Italo; Chojniak, Rubens; Costa Silva, Debora Helena; Oliveira Junior, Jose Carlos; Vieira Bitencourt, Almir Galvão; Holanda Silva, Diego; Guimarães, Marcos Duarte; Silva, Hernandes Cerqueira Souza; Dias, Denis Guilherme Teixeira; Rodrigues, Winglison Carli; Brancucci, Ellen Luzia; Cruz, Barbara Martins Soares; Schiavon, Beatriz Nunes; Argenton, Juliana Luz Passos; Camporini, Margareth Arrivabene; Zocchio, Adriana

    2015-01-01

    Our aim was to assess renal function using as laboratory measurements serum creatinine and cystatin C concentrations before and after administration of low-osmolarity (nonionic) iodinated contrast medium in patients with cancer undergoing computed tomography (CT). This prospective study included 400 oncologic outpatients. Serum creatinine and cystatin C concentrations were measured before and 72 h after contrast administration. Glomerular filtration rates (GFRs) were estimated using serum creatinine-based [Modification of Diet in Renal Disease (MDRD) and Cockroft-Gault and cystatin C based (Larsson) equations. Exploratory data analysis was performed. The nonparametric Wilcoxon test was used to compare pre and post contrast of test results and estimated clearance. The confidence interval used in the analysis was 95%. Compared with the pre-contrast values, the mean serum creatinine concentration was significantly higher and average GFRs estimated using MDRD and Cockcroft-Gault equations were significantly lower after the administration of contrast (p serum creatinine and cystatin C concentrations showed changes in renal function among patients with cancer undergoing contrast-enhanced CT examination in this study. No significant renal damage related to the use of low-osmolarity iodinated contrast medium of the type and dosage employed in this study was observed. This contrast medium is thus safe for use in patients with cancer.

  20. Animal Locomotion in Different Mediums

    Indian Academy of Sciences (India)

    Wetlands are repositories of unique biodiversity. Wetlandorganisms are well adapted to their habitat, lying at theinterface of aquatic and terrestrial environments. In order tounderstand their adaptations in a better way, it is essential tograsp the basic properties of the medium in which variousorganisms live. This is attempted ...

  1. Animal Locomotion in Different Mediums

    Indian Academy of Sciences (India)

    IAS Admin

    Fishes, moving in water encounter drag forces, which can be of considerable magnitude. If sudden movement is required to catch prey or escape predators in a viscous medium, it is only possible by the contraction of fast, white muscle fibres, which rely on anaerobic glycolysis pathways. Therefore, it is not surprising that.

  2. Molecular spectroscopy of interstellar medium

    International Nuclear Information System (INIS)

    Varshalovich, D.A.; Khersonskij, V.K.

    1980-01-01

    Experimental data obtained in the investigation into molecules of interstellar medium by molecular-spectroscopic methods are discussed generally. Ion-molecule reactions play a significant part in the formation of multiatom molecules in the interstellar medium as well as reactions proceeding on the surface of interstellar dust. More than 50 types of molecules have been detected in the interstellar medium at present. In a wide range of wave lengths over 500 spectral lines belonging to various molecules and molecular fragments have been recorded. Interstellar molecules permit to investigate interstellar gas from all the sides. They are a suitable indicator of the isotope composition of interstellar gas. Radio observations of interstellar molecules make it possible to effectively investigate kinematics and space structure both separate gas-dust complexes and total gas distribution in Galaxy. It is noted that achievements of molecular spectroscopy of the interstellar medium radically change representations of the chemical composition of interstellar gas, of isotope abundance and organic substance in the Universe

  3. Hadron photoproduction at medium energy

    International Nuclear Information System (INIS)

    Dainton, J.B.

    1985-04-01

    Results from measurements of multibody photoproduction at medium incident photon energy (2.8 to 4.8 GeV) are presented and discussed. Particular emphasis is placed on topics which are not well understood and which therefore motivate experiments with the upgraded electron accelerator and storage ring ELSA at the University of Bonn, FR Germany. (author)

  4. Impairment of the glymphatic system after diabetes

    DEFF Research Database (Denmark)

    Jiang, Quan; Zhang, Li; Ding, Guangliang

    2017-01-01

    diabetes affects the glymphatic system. The current study is the first investigation of the effect of diabetes on the glymphatic system and the link between alteration of glymphatic clearance and cognitive impairment in Type-2 diabetes mellitus rats. MRI analysis revealed that clearance of cerebrospinal...... to the retention of Gd-DTPA contrast and fluorescent tracer in the hippocampus of Type-2 diabetes mellitus rats. Type-2 diabetes mellitus suppresses clearance of interstitial fluid in the hippocampus and hypothalamus, suggesting that an impairment of the glymphatic system contributes to Type-2 diabetes mellitus...

  5. Diagnostic imaging of maxillofacial lesions with CT and MRI.

    Science.gov (United States)

    Ito, J

    1990-01-01

    Normal anatomy of the maxillofacial regions is clearly shown by both CT and MRI. The use of dental devices causes deterioration in CT and MRI of the tongue and oral floor. A high-resolution bone window display is highly useful in examining bony structures. Contrast CT is useful in diagnosis of tumorous, inflammatory, and vascular lesions. MRI shows the extensions of tumors more clearly than CT, and MRI enhanced with Gd-DTPA is very useful in determining tumor extensions into bony structures. Both CT and MRI should be used in diagnosis of maxillofacial lesions.

  6. Preoperative diagnosis of tumors of the head and neck with CT and MIR-imaging. A comparison of techniques with special reference to a dynamic FLASH-2D-sequence

    International Nuclear Information System (INIS)

    Maeurer, J.; Vogl, T.J.; Steinkamp, H.J.; Tykocinski, M.; Helwig, A.

    1993-01-01

    Thirty-eight patients with clinically confirmed head and neck tumors were examined by computed tomography (CT) and magnetic resonance imaging (MRI). The results of CT, dynamic FLASH-2D-sequence and a Gd-DTPA enhanced T1-weighted sequence were analysed and compared with surgical and pathological findings. The extent of tumors was clearly defined by the dynamic technique in 21 cases. Furthermore it was superior for the purposes of demonstrating contrast behavior and concerning T-classification. Diagnostic findings of CT correlated in 79% with N-classification, while MRI provides exact information in 72%. (orig.) [de

  7. Medium term ecohydrological response of peatland bryophytes to canopy disturbance

    Science.gov (United States)

    Leonard, Rhoswen; Kettridge, Nick; Krause, Stefan; Devito, Kevin; Granath, Gustaf; Petrone, Richard; Mandoza, Carl; Waddington, James Micheal

    2016-04-01

    Canopy disturbance in northern forested peatlands is widespread. Canopy changes impact the ecohydrological function of moss and peat, which provide the principal carbon store within these carbon rich ecosystems. Different mosses have contrasting contributions to carbon and water fluxes (e.g. Sphagnum fuscum and Pleurozium schreberi) and are strongly influenced by canopy cover. As a result, changes in canopy cover lead to long-term shifts in species composition and associated ecohydrological function. Despite this, the medium-term response to such disturbance, the associated lag in this transition to a new ecohydrological and biogeochemical regime, is not understood. Here we investigate this medium term ecohydrological response to canopy removal using a randomised plot design within a north Albertan peatland. We show no significant ecohydrological change in treatment plots four years after canopy removal. Notably, Pleurozium schreberi and Sphagnum fuscum remained within respective plots post treatment and there was no significant difference in plot resistance to evapotranspiration or carbon exchange. Our results show that canopy removal alone has little impact on bryophyte ecohydrology in the short/medium term. This resistance to disturbance contrasts strongly with dramatic short-term changes observed within mineral soils suggesting that concurrent shifts in the large scale hydrology induced within such disturbances are necessary to cause rapid ecohydrological transitions. Understanding this lagged response is critical to determine the decadal response of carbon and water fluxes in response to disturbance and the rate at which important medium term ecohydrological feedbacks are invoked.

  8. The new numbers contrast sensitivity chart for contrast sensitivity measurement

    Directory of Open Access Journals (Sweden)

    Bharkbhum Khambhiphant

    2011-10-01

    Conclusions: These charts show reasonable agreement and can be used interchangeably with the MARS. It is helpful for Thai people who can only read numbers in doing the test. We can use them in routinely contrast sensitivity measurement.

  9. Dynamic MR imaging of the temporomandibular joint arthrosis using spoiled GRASS sequence

    Energy Technology Data Exchange (ETDEWEB)

    Suenaga, Shigeaki; Hamamoto, Sadatoshi; Kawano, Kazunori (Kagoshima Univ. (Japan). Dental School) (and others)

    1994-07-01

    The purpose of this study was to quantitatively evaluate contrast enhancement effects of the posterior disk attachment in the temporomandibular joint arthrosis using dynamic MRI with bilateral surface coils. One hundred twenty-four temporomandibular joints in 96 symptomatic patients and 27 control subjects were examined with a spoiled GRASS pulse sequence (TR: 35 ms, TE: 8 ms, flip angle: 60deg). One sagittal scan was performed prior to injection, then 0.1 mmol/kg of