WorldWideScience

Sample records for contrast echocardiography correlates

  1. The Value of Contrast Echocardiography

    Directory of Open Access Journals (Sweden)

    Shannon C. Treiber

    2016-01-01

    Full Text Available Purpose: There is much evidence-based research proving the effectiveness of contrast echocardiography, but there are still questions and concerns about its specific uses. This study tested the effectiveness of contrast echocardiography in defining the left ventricular endocardial border. Methods: From 30 patients, a total of 60 echocardiograms –– 30 with and 30 without use of contrast –– were retrospectively reviewed by four blinded cardiologists with advanced training in echocardiography. No single cardiologist reviewed contrast and noncontrast images of the same patient. Each set of 30 echocardiograms was then studied for wall-motion scoring. Visualization of left ventricular wall segments and a global visualization confidence level of interpretation were recorded. Results: Of all wall segments (N = 510, 91% were visualized in echocardiograms with use of contrast, whereas 75% of the walls were visualized in echocardiograms without contrast (P < 0.001. Of 30 examinations, 17 contrast echocardiograms were read with high confidence compared to 6 without contrast use (P = 0.004. The number of walls visualized with contrast was increased in 18 patients (60%, whereas noncontrast echocardiograms yielded more visualized walls in 6 patients (20%, P = 0.002. Conclusions: This study demonstrates that contrast is valuable to echocardiographic imaging. Its use should be supported throughout echocardiography clinics and encouraged in certain patients for whom resting and stress echocardiography results without contrast often prove uninterpretable.

  2. Safety of ultrasound contrast agents in stress echocardiography.

    Science.gov (United States)

    Gabriel, Ruvin S; Smyth, Yvonne M; Menon, Venu; Klein, Allan L; Grimm, Richard A; Thomas, James D; Sabik, Ellen Mayer

    2008-11-01

    Definity and Optison are perflutren-based ultrasound contrast agents used in echocardiography. United States Food and Drug Administration warnings regarding serious cardiopulmonary reactions and death after Definity administration highlighted the limited safety data in patients who undergo contrast stress echocardiography. From 1998 and 2007, 2,022 patients underwent dobutamine stress echocardiography and 2,764 underwent exercise stress echocardiography with contrast at the Cleveland Clinic. The echocardiographic database, patient records, and the Social Security Death Index were reviewed for the timing and cause of death, severe adverse events, arrhythmias, and symptoms. Complication rates for contrast dobutamine stress echocardiography and exercise stress echocardiography were compared with those in a control group of 5,012 patients matched for test year and type who did not receive contrast. Ninety-five percent of studies were performed in outpatients. There were no differences in the rates of severe adverse events (0.19% vs 0.17%, p = 0.7), death within 24 hours (0% vs 0.04%, p = 0.1), cardiac arrest (0.04% vs 0.04%, p = 0.96), and sustained ventricular tachycardia (0.2% vs 0.1%, p = 0.32) between patients receiving and not receiving intravenous contrast, respectively. In conclusion, severe adverse reactions to intravenous contrast agents during stress echocardiography are uncommon. Contrast use does not add to the baseline risk for severe adverse events in patients who undergo stress echocardiography.

  3. Clinical applications of contrast echocardiography

    International Nuclear Information System (INIS)

    Jorge, Leon Galindo

    2005-01-01

    The echocardiography is the technique more used for the diagnosis and pursuit of the cardiovascular illnesses; therefore, their diagnostic precision has acquired a vital importance in the handling of the patients with cardiovascular pathologies. However, with relative frequency, the diagnostic capacity of the echocardiography exam is diminished by limitations of the acoustic window, mainly in-patient with obesity, lung illnesses and alterations of the thoracic wall. This can be obviated with the use of the intra-esophagus echocardiography, although this it is a procedure semi-invasive and not very practical of carrying out in all the patients with problems of acoustic window. In this article the clinical applications are revised more common of the contrast echocardiography

  4. "3D fusion" echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography.

    Science.gov (United States)

    Augustine, Daniel; Yaqub, Mohammad; Szmigielski, Cezary; Lima, Eduardo; Petersen, Steffen E; Becher, Harald; Noble, J Alison; Leeson, Paul

    2015-02-01

    Three-dimensional fusion echocardiography (3DFE) is a novel postprocessing approach that utilizes imaging data acquired from multiple 3D acquisitions. We assessed image quality, endocardial border definition, and cardiac wall motion in patients using 3DFE compared to standard 3D images (3D) and results obtained with contrast echocardiography (2DC). Twenty-four patients (mean age 66.9 ± 13 years, 17 males, 7 females) undergoing 2DC had three, noncontrast, 3D apical volumes acquired at rest. Images were fused using an automated image fusion approach. Quality of the 3DFE was compared to both 3D and 2DC based on contrast-to-noise ratio (CNR) and endocardial border definition. We then compared clinical wall-motion score index (WMSI) calculated from 3DFE and 3D to those obtained from 2DC images. Fused 3D volumes had significantly improved CNR (8.92 ± 1.35 vs. 6.59 ± 1.19, P echocardiography (1.06 ± 0.09 vs. 1.07 ± 0.15, P = 0.69), whereas unfused images produced significantly more variable results (1.19 ± 0.30). This was confirmed by a better intraclass correlation coefficient (ICC 0.72; 95% CI 0.32-0.88) relative to comparisons with unfused images (ICC 0.56; 95% CI 0.02-0.81). 3DFE significantly improves left ventricular image quality compared to unfused 3D in a patient population and allows noncontrast assessment of wall motion that approaches that achieved with 2D contrast echocardiography. © 2014, Wiley Periodicals, Inc.

  5. Application of Contrast Echocardiography in Invasive Cardiology

    Directory of Open Access Journals (Sweden)

    Mustafa Bulut

    2010-12-01

    Full Text Available Contrast echocardiography by rendering better imaging of the borders of cardiac chambers is a useful tool for evaluating cardiac function, mass, myocardial vascularization, microvascular structure (small vessel vasculature and viability. Contrast was first started to be used for patients with suboptimal image quality. It can be used in detecting defects in myocardial blood supply in patients with chest pain and determining the success of interventionalprocedures. It can also be of help in demonstrating myocardial viability after reperfusion treatment in patients who had myocardial infarction. It is expected to be used more widely in invasive cardiology for decision making, guiding and determining the success of the procedures. Advances in imaging techniques , development of contrast materials for evaluation of left system, contrast echocardiography may become a routine clinical practice.

  6. Contrast echocardiography: history, micro bubble characteristics and instrumental techniques

    International Nuclear Information System (INIS)

    Cubides, Carlos; Restrepo, Gustavo; Aristizabal, Dagnovar; Munera, Ana

    2006-01-01

    This article describes the history of contrast echocardiography, the physical characteristics of the contrast agent's micro bubbles, the main instrumental tools (mechanical index, focus and focusing, frame rate), and the echocardiography techniques (second harmonic imaging, fusion harmonic, power pulse inversion imaging, triggered imaging, intermittent harmonic power Doppler, color power angio and acoustic densitometry), actually available for clinical use

  7. Prediction of wall motion improvement after coronary revascularization in patients with postmyocardial infarction. Diagnostic value of dobutamine stress echocardiography and myocardial contrast echocardiography

    International Nuclear Information System (INIS)

    Waku, Sachiko; Ohkubo, Tomoyuki; Takada, Kiyoshi; Ishihara, Tadashi; Ohsawa, Nakaaki; Adachi, Itaru; Narabayashi, Isamu

    1997-01-01

    The diagnostic value of dobutamine stress echocardiography, myocardial contrast echocardiography and dipyridamole stress thallium-201 single photon emission computed tomography (SPECT) for predicting recovery of wall motion abnormality after revascularization was evaluated in 13 patients with postmyocardial infarction. Seventeen segments showed severe wall motion abnormalities before revascularization. Nine segments which had relatively good Tl uptake on delayed SPECT images despite severely abnormal wall motion were opacified during myocardial contrast echocardiography, and showed improved wall motion after revascularization. In contrast, three segments which had poor Tl uptake and severely abnormal wall motion were not opacified during myocardial contrast echocardiography, and showed no improvement in wall motion during dobutamine stress echocardiography and after revascularization. The following three findings were assumed to be signs of myocardial viability: good Tl uptake on delayed SPECT images, improved wall motion by dobutamine stress echocardiography, and positive opacification of the myocardium by myocardiai contrast echocardiography. Myocardial contrast echocardiography had the highest sensitivity (100%) and negative predictive value (100%). Delayed SPECT images had the highest specificity (100%) and positive predictive value (100%). Dobutamine stress echocardiography had a sensitivity of 83.0%, specificity of 80.0%, positive predictive value of 90.9%, and negative predictive value of 66.7%, respectively. Myocardial contrast echocardiography showed the lowest specificity (60.0%). The techniques of dobutamine stress echocardiography and SPECT, though noninvasive, may underestimate wall motion improvement after revascularization. Further examination by myocardial contrast echocardiography is recommended to assess myocardial viability for determining the indications for coronary revascularization in spite of its invasiveness. (author)

  8. The relationship between pulmonary artery wedge pressure and pulmonary blood volume derived from contrast echocardiography: A proof-of-concept study.

    Science.gov (United States)

    Monahan, Ken; Lenihan, Daniel; Brittain, Evan L; Saliba, Linda; Piana, Robert N; Robison, Leslie L; Hudson, Melissa M; Armstrong, Gregory T

    2018-05-14

    Pulmonary transit time (PTT) obtained from contrast echocardiography is a marker of global cardiopulmonary function. Pulmonary blood volume (PBV), derived from PTT, may be a noninvasive surrogate for left-sided filling pressures, such as pulmonary artery wedge pressure (PAWP). We sought to assess the relationship between PBV obtained from contrast echocardiography and PAWP. Participants were adult survivors of childhood cancer that had contrast echocardiography performed nearly simultaneously with right-heart catheterization. PTT was derived from time-intensity curves of contrast passage through the right ventricle (RV) and left atrium (LA). PBV relative to overall stroke volume (rPBV) was estimated from the product of PTT and heart rate during RV-LA transit. PAWP was obtained during standard right-heart catheterization. The Spearman correlation coefficient was used to assess the relationship between rPBV and PAWP. The study population consisted of 7 individuals who had contrast echocardiography and right-heart catheterization within 3 hours of each other. There was a wide range of right atrial (1-17 mm Hg), mean pulmonary artery (18-42 mm Hg), and PAW pressures (4-26 mm Hg) as well as pulmonary vascular resistance (<1-6 Wood Units). We observed a statistically significant correlation between rPBV and PAWP (r = .85; P = .02). Relative PBV derived from contrast echocardiography correlates with PAWP. If validated in larger studies, rPBV could potentially be used as an alternative to invasively determine left-sided filling pressure. © 2018 Wiley Periodicals, Inc.

  9. Influence of contrast agent dose and ultrasound exposure on cardiomyocyte injury induced by myocardial contrast echocardiography in rats.

    Science.gov (United States)

    Miller, Douglas L; Li, Peng; Dou, Chunyan; Gordon, David; Edwards, Chris A; Armstrong, William F

    2005-10-01

    To detect specific cardiomyocyte injury induced by myocardial contrast material-enhanced echocardiography (ie, myocardial contrast echocardiography) in rats and to ascertain the influences of contrast material dose and ultrasound exposure on this injury. All animal procedures were approved by the university committee for the use and care of animals. Myocardial contrast echocardiography with 1:4 electrocardiographic (ECG) triggering was performed at 1.5 MHz in 61 anesthetized rats. Evans blue (EB) dye was injected as the vital stain for cardiomyocyte injury. At the start of myocardial contrast echocardiography, which lasted 10 minutes, perflutren lipid microsphere-based contrast material was infused through the tail vein for 5 minutes. Premature heartbeats were counted from the ECG record. The numbers of EB-stained cells counted on sections of heart specimens obtained 24 hours after myocardial contrast echocardiography and then either fresh frozen or embedded in paraffin were determined by using fluorescence microscopy. Results were compared statistically by using t tests and Mann-Whitney rank sum tests. EB-stained cells were concentrated in the anterior region of the myocardium. In the paraffin-embedded specimens, EB-stained cells were often accompanied by but largely separate from areas of inflammatory cell infiltration. At end-systolic triggering with a 50 microL/kg dose of microsphere contrast material, the EB-stained cell count increased with increasing peak rarefactional pressure amplitude, with significantly increased cell counts at 1.6 MPa (P .1). EB-stained cell counts increased with increasing contrast material dose, from 10 to 50 microL/kg, at 2.0 MPa. Cardiomyocyte injury was induced by the interaction of ultrasound pulses with contrast agent microbubbles during myocardial contrast echocardiography in rats, and the numbers of injured cells increased with increasing contrast agent dose and ultrasound exposure. RSNA, 2005

  10. Contrast agents provide a faster learning curve in dipyridamole stress echocardiography.

    Science.gov (United States)

    Zamorano, Jose; Sánchez, Violeta; Moreno, Raúl; Almería, Carlos; Rodrigo, Jose; Serra, Viviana; Azcona, Luis; Aubele, Adalia; Mataix, Luis; Sánchez-Harguindey, Luis

    2002-12-01

    Interobserver variability is an important limitation of the stress echocardiography and depends on the echocardiographer training. Our aim was to evaluate if the use of contrast agents during dipyridamole stress echocardiography would improve the agreement between an experienced and a non-experienced observer in stress echo and therefore if contrast would affect the learning period of dypyridamole stress echo. Two independent observers without knowledge of any patient data interpreted all stress studies. One observer was an experienced one and the other had experience in echocardiography but not in stress echo. Two observers analysed 87 non-selected and consecutive studies. Out of the 87 studies, 46 were performed without contrast administration, whereas i.v. contrast (2.5 g Levovist by two bolus at rest and at peak stress) was administered in 41. In all cases, second harmonic imaging and stress digitalisation pack was used. The agreement between observers showed a kappa index of 0.58 and 0.83 without and with contrast administration, respectively. The use of contrast agents provides a better agreement in the evaluation of stress echo between an experienced and a non-experienced observer in stress echo. Adding routinely contrast agents could probably reduce the number of exams required for the necessary learning curve in stress echocardiography.

  11. Incremental value of contrast echocardiography in the evaluation of a cardiac thrombus.

    Science.gov (United States)

    Po, Jose Ricardo F; Tong, Matthew S; Grove, Erica L; Biederman, Robert W W

    2017-02-01

    A 52-year-old man presented with altered mental status and report of prior complaint of chest pain. On electrocardiography, anterolateral ST-segment elevations with Q-waves in the septal leads were seen. Initial echocardiography images demonstrated a thickened anteroseptum. Further imaging showed the presence of a well-attached laminated apical thrombus. Contrast echocardiography images showed that the thrombus had minimal attachment to the endocardial surface. CT head subsequently showed the presence of acute stroke. The case demonstrates the additional value of contrast echocardiography in the evaluation of cardiac masses despite the certainty in the diagnosis of a thrombus. © 2017, Wiley Periodicals, Inc.

  12. TIA Caused by Contrast Echocardiography in Patient with Platypnea-Orthodeoxia.

    Science.gov (United States)

    Loncar, Goran; Payot, Laurent; Dubois, Mathieu

    2015-10-01

    Platypnea-orthodeoxia syndrome (POS) is a rare clinical disorder characterized by dyspnea caused by the upright position and relieved at recumbent position. Few cases of POS and stroke were reported in literature, and the association between stroke and POS with evidence of patent foramen ovale (PFO) is rare. Stroke may occur in patients with cardiac shunt who undergo contrast echocardiography. We present a patient with POS who experienced transitory ischemic attack (TIA) most likely caused by injection of agitated saline microbubbles during screen for PFO. No case report of TIA/stroke during contrast echocardiography in patients with POS has previously been published. © 2015, Wiley Periodicals, Inc.

  13. Saline Contrast Echocardiography in the Era of Multimodality Imaging--Importance of "Bubbling It Right".

    Science.gov (United States)

    Gupta, Saurabh K; Shetkar, Sudhir S; Ramakrishnan, Sivasubramanian; Kothari, Shyam S

    2015-11-01

    Saline contrast echocardiography is an established imaging modality. Logical interpretation of a carefully performed study is vital to realize its diagnostic potential. In this review, we discuss utility of saline contrast echocardiography in evaluation of various pathologies within and outside the heart other than a patent foramen ovale. © 2015, Wiley Periodicals, Inc.

  14. Myocardial Contrast Agents – Safety Considerations and Clinical Efficacy in Stress Echocardiography

    Directory of Open Access Journals (Sweden)

    Maier Anca

    2016-11-01

    Full Text Available Transthoracic echocardiographic examination is known to be a safe, non-invasive and reproducible method, used in every day clinical practice to obtain important information about cardiac structure and function. Unfortunately, a significant proportion of studies have highlighted the considerable technically difficultly in producing diagnostic images due to a poor acoustic window and more than 33% of patients undergoing stress echocardiography have suboptimal echocardiographic images. All these limitations have led to the use of contrast agents to improve the quality of standard ultrasound examination to provide a better delineation of left ventricle endocardial borders or to obtain information that cannot be achieved by using standard echocardiography, such as assessing myocardial microcirculation and therefore perfusion. This paper sought to review the clinical efficacy and safety of ultrasound contrast agents focusing on stress echocardiography.

  15. Instrumentation for contrast echocardiography: technology and techniques.

    Science.gov (United States)

    Kaul, Sanjiv

    2002-11-18

    Contrast echocardiography is the only clinical imaging technique in which the imaging modality (ultrasound) can cause a change in the contrast agent (microbubbles). The change in the contrast agent can range from small oscillations of the microbubbles at a low mechanical index to their disruption at a high mechanical index. The specific mechanical index required to produce these various effects may be different for each contrast agent, depending on the bubble dimension as well as shell and gas characteristics. These alterations in bubbles result in changes in ultrasound backscatter that are specific for the bubbles themselves, rather than for tissue, and are therefore exploited for imaging their presence in tissue. These signal-processing techniques have resulted in an increased signal-to-noise ratio from bubbles vis-à-vis the tissue and have made online assessment of myocardial perfusion possible.

  16. Value of adenosine infusion for infarct size determination using real-time myocardial contrast echocardiography

    Directory of Open Access Journals (Sweden)

    da Luz Protásio

    2006-02-01

    Full Text Available Abstract Background Myocardial contrast echocardiography has been used for determination of infarct size (IS in experimental models. However, with intermittent harmonic imaging, IS seems to be underestimated immediately after reperfusion due to areas with preserved, yet dysfunctional, microvasculature. The use of exogenous vasodilators showed to be useful to unmask these infarcted areas with depressed coronary flow reserve. This study was undertaken to assess the value of adenosine for IS determination in an open-chest canine model of coronary occlusion and reperfusion, using real-time myocardial contrast echocardiography (RTMCE. Methods Nine dogs underwent 180 minutes of coronary occlusion followed by reperfusion. PESDA (Perfluorocarbon-Exposed Sonicated Dextrose Albumin was used as contrast agent. IS was determined by RTMCE before and during adenosine infusion at a rate of 140 mcg·Kg-1·min-1. Post-mortem necrotic area was determined by triphenyl-tetrazolium chloride (TTC staining. Results IS determined by RTMCE was 1.98 ± 1.30 cm2 and increased to 2.58 ± 1.53 cm2 during adenosine infusion (p = 0.004, with good correlation between measurements (r = 0.91; p 2 and showed no significant difference with IS determined by RTMCE before or during hyperemia. A slight better correlation between RTMCE and TTC measurements was observed during adenosine (r = 0.99; p Conclusion RTMCE can accurately determine IS in immediate period after acute myocardial infarction. Adenosine infusion results in a slight better detection of actual size of myocardial damage.

  17. Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.

    Science.gov (United States)

    He, Jiang-Chun; Zheng, Jian-Yong; Li, Xin; Yang, Ye; Zhang, Bo-Yang; Chen, Yu; Li, Xian-Feng; Liu, Ying-Ming; Cao, Yi; Zhao, Li; Li, Tian-Chang

    2017-08-01

    To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ 2 =5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.

  18. The effect of introduction of axial cineangiography and echocardiography on contrast and radiation doses during cardiac catheterisation

    International Nuclear Information System (INIS)

    Sweet, E.M.; McLardy, J.L.

    1984-01-01

    The effects of routine preliminary echocardiography and adoption of axial cine angiography in a Paediatric Cardiac Investigation Centre were assessed in relation to contrast volume, fluoroscopy time and radiation dose. The results showed a significant increase in radiation dose with some reduction in fluoroscopy time in neonates and some increase in contrast volume used in infants [fr

  19. A ecocardiografia com contraste no diagnóstico de dilatações vasculares intrapulmonares em candidatos ao transplante hepático Contrast echocardiography in the diagnosis of intrapulmonary vascular dilations in candidates for liver transplantation

    Directory of Open Access Journals (Sweden)

    Paulo Roberto Pavarino

    2004-06-01

    intracardiac communications, who underwent transthoracic echocardiography with second harmonic imaging. Thirty-two of them underwent consecutive transesophageal study. The result of contrast echocardiography was considered positive when the presence of contrast was detected in the left cardiac chambers with a delay of 4 to 6 cardiac cycles after initial opacification of the right cardiac chambers. RESULTS: The prevalence of intrapulmonary vascular dilations was 53.9% (41/76 patients. The sensitivity, specificity, positive and negative predictive values, and accuracy of transthoracic echocardiography as compared with those of transesophageal echocardiography for confirming pulmonary vascular abnormalities in patients with liver disease were, respectively, 75%, 100%, 100%, 80%, and 87.5%. The degree of arterial oxygenation showed no correlation with the occurrence of a positive echocardiographic study. Arterial hypoxemia (PaO2 < 70 mm Hg was observed in 9 (15.9% of the 76 patients. The echocardiographic study was positive in 37 (55.2% of the 67 nonhypoxemic patients and in 4 (44.4% of the 9 hypoxemic ones. CONCLUSION: Contrast echocardiography proved to be effective, easy, and safe to use in candidates for liver transplantation. Transthoracic echocardiography may be used in the diagnostic routine of intrapulmonary vascular dilations, the transesophageal study being reserved for inconclusive cases with clinical suspicion.

  20. Effect of streptozotocin-induced diabetes on myocardial blood flow reserve assessed by myocardial contrast echocardiography in rats

    Directory of Open Access Journals (Sweden)

    Weytjens Caroline

    2008-09-01

    Full Text Available Abstract The role of structural and functional abnormalities of small vessels in diabetes cardiomyopathy remains unclear. Myocardial contrast echocardiography allows the quantification of myocardial blood flow at rest and during dipyridamole infusion. The aim of the study was to determine the myocardial blood flow reserve in normal rats compared with Streptozotocin-induced diabetic rats using contrast echocardiography. Methods We prospectively studied 40 Wistar rats. Diabetes was induced by intravenous streptozotocin in 20 rats. All rats underwent baseline and stress (dipyridamole: 20 mg/kg high power intermittent imaging in short axis view under anaesthesia baseline and after six months. Myocardial blood flow was determined and compared at rest and after dipyridamole in both populations. The myocardial blood flow reserve was calculated and compared in the 2 groups. Parameters of left ventricular function were determined from the M-mode tracings and histological examination was performed in all rats at the end of the study. Results At six months, myocardial blood flow reserve was significantly lower in diabetic rats compared to controls (3.09 ± 0.98 vs. 1.28 ± 0.67 ml min-1 g-1; p Conclusion In this animal study, diabetes induced a functional alteration of the coronary microcirculation, as demonstrated by contrast echocardiography, a decrease in capillary density and of the cardiac systolic function. These findings may offer new insights into the underlying mechanisms of diabetes cardiomyopathy.

  1. Determinants of Pediatric Echocardiography Laboratory Productivity: Analysis from the Second Survey of the American Society of Echocardiography Committee on Echocardiography Laboratory Productivity.

    Science.gov (United States)

    Srivastava, Shubhika; Allada, Vivekanand; Younoszai, Adel; Lopez, Leo; Soriano, Brian D; Fleishman, Craig E; Van Hoever, Andrea M; Lai, Wyman W

    2016-10-01

    The American Society of Echocardiography Committee on Pediatric Echocardiography Laboratory Productivity aimed to study factors that could influence the clinical productivity of physicians and sonographers and assess longitudinal trends for the same. The first survey results indicated that productivity correlated with the total volume of echocardiograms. Survey questions were designed to assess productivity for (1) physician full-time equivalent (FTE) allocated to echocardiography reading (echocardiograms per physician FTE per day), (2) sonographer FTE (echocardiograms per sonographer FTE per year), and (3) machine utilization (echocardiograms per machine per year). Questions were also posed to assess work flow and workforce. For fiscal year 2013 or academic year 2012-2013, the mean number of total echocardiograms-including outreach, transthoracic, fetal, and transesophageal echocardiograms-per physician FTE per day was 14.3 ± 5.9, the mean number of echocardiograms per sonographer FTE per year was 1,056 ± 441, and the mean number of echocardiograms per machine per year was 778 ± 303. Both physician and sonographer productivity was higher at high-volume surgical centers and with echocardiography slots scheduled concordantly with clinic visits. Having an advanced imaging fellow and outpatient sedation correlated negatively with clinical laboratory productivity. Machine utilization was greater in laboratories with higher sonographer and physician productivity and lower for machines obtained before 2009. Measures of pediatric echocardiography laboratory staff productivity and machine utilization were shown to correlate positively with surgical volume, total echocardiography volumes, and concordant echocardiography scheduling; the same measures correlated negatively with having an advanced imaging fellow and outpatient sedation. There has been no significant change in staff productivity noted over two Committee on Pediatric Echocardiography Laboratory

  2. The usefulness of contrast during exercise echocardiography for the assessment of systolic pulmonary pressure

    Directory of Open Access Journals (Sweden)

    Cordeiro Ana

    2008-10-01

    Full Text Available Abstract Background The systolic pulmonary artery pressure (PAPs can be accurately estimated, non-invasively, using continuous-wave Doppler (CWD ultrasound measurement of the peak velocity of a tricuspid regurgitant (TR jet. However, it is often difficult to obtain adequate tricuspid regurgitation signals for measurement of PAPs, what could lead to its underestimation. Therefore, utilization of air-blood-saline contrast has been implemented for the improvement of Doppler signal in several clinical contexts. It is now recommended in the evaluation of patients with pulmonary hypertension. Physical activity is severely restricted in patients with PAH, being exertional dypnea the most typical symptom. Exercise stress echo-Doppler imaging allows assessment of the response to exercise. It is an excellent screening test for patients with suspected PAH. Our purpose was to evaluate the value and accuracy of agitated saline with blood contrast echocardiography, in the improvement of the Doppler signal, to quantify PAPs during treadmill exercise-echocardiography. Purpose To evaluate the value of contrast echocardiography, using agitated saline with blood, in the improvement of the Doppler signal used to quantify the pulmonary artery systolic pressure during exercise. Methods From a total of 41 patients (pts, we studied 38 pts (93%, 35 women, aged 54 ± 12 years-old. 27 with the diagnosis of systemic sclerosis, 10 with history of pulmonary embolism and one patient with a suspected idiopathic PAH, who were referred to the Unity of Heart Failure and Pulmonary Hypertension for screening of PAH. According to the Unity protocol, a transthoracic echocardiogram was made, in left decubitus (LD, with evaluation of right ventricle-right atria gradient (RV/RAg. A peripheral venous access was obtained, with a 3-way stopcock and the patients were placed in orthostatism (O, with a new evaluation of RV/RAg. Exercise echocardiography (EE was begun, with evaluation of RV

  3. Semi-quantitative assessment of tricuspid regurgitation on contrast-enhanced multidetector CT

    International Nuclear Information System (INIS)

    Groves, A.M.; Win, T.; Charman, S.C.; Wisbey, C.; Pepke-Zaba, J.; Coulden, R.A.

    2004-01-01

    AIM: To assess whether the early regurgitation of intravenous contrast medium into the inferior vena cava (IVC) and/or hepatic veins on computed tomography (CT), indicates tricuspid regurgitation (TR), and if so, whether it be used to grade severity. MATERIALS AND METHODS: We identified 86 consecutive patients that had been investigated for possible pulmonary endarterectomy at Papworth Hospital. From these, 61 patients were selected in whom CT, transthoracic echocardiography, and right heart catheterization (RHC) had been performed within 6 weeks. Using an arbitrary visual scale, the degree of TR assessed by intravenous contrast-enhanced CT was compared with echocardiography. Results were analysed using a kappa weighted statistical test. In addition, CT and echocardiographic assessments of TR severity were correlated with pulmonary artery pressure measurements obtained by RHC (Spearman's rank correlation coefficient). RESULTS: CT assessment of TR had a sensitivity of 90.4% and a specificity of 100% in detecting echocardiographic TR. For TR graded as more than trivial by echocardiography, sensitivity of CT was 100%. With respect to RHC data, the correlation between severity assessment of TR between CT and echocardiography using the Kappa weighted coefficient was 0.56 (moderately good agreement). With respect to RHC data, the correlation between mean pulmonary pressure and TR grading on CT and echocardiography was r=0.685 (p<0.001) and r=0.727 (p<0.001), respectively. CONCLUSION: Early opacification of the IVC or hepatic veins on first-pass contrast-enhanced CT almost invariably indicates TR. There is moderately good agreement between CT and echocardiographic assessment of the severity of TR. Both CT and echocardiographic grading of TR correlate well with RHC measurements of pulmonary artery pressure

  4. When to use femoral vein injection for diagnosis of patent foramen ovale-Effect of a persistent eustachian valve on right atrial flow patterns during contrast transesophageal echocardiography.

    Science.gov (United States)

    Koh, Tat W

    2017-05-01

    Contrast echocardiography using agitated saline injected into the antecubital vein is the most common method used for the diagnosis of patent foramen ovale. We describe a case whereby the presence of a persistent eustachian valve and a "negative contrast sign" during contrast transesophageal echocardiography raised suspicion of a false-negative result. Femoral vein injection of contrast successfully demonstrated a patent foramen ovale. Femoral vein injection should be considered if this scenario is recognized because the eustachian valve directs blood preferentially from the inferior vena cava toward the interatrial septum and this route may prove to be more reliable. © 2017, Wiley Periodicals, Inc.

  5. Prenatal Diagnosis of Fetal Interrupted Aortic Arch Type A by Two-Dimensional Echocardiography and Four-Dimensional Echocardiography with B-Flow Imaging and Spatiotemporal Image Correlation.

    Science.gov (United States)

    Zhang, Dongyu; Zhang, Ying; Ren, Weidong; Sun, Feifei; Guo, Yajun; Sun, Wei; Wang, Yu; Huang, Liping; Cai, Ailu

    2016-01-01

    Fetal interrupted aortic arch (IAA) is a rare cardiac anomaly and its prenatal diagnosis is challenging. The purpose of our report is to evaluate the use of two-dimensional echocardiography (2DE) and 4D echocardiography with B-flow imaging and spatiotemporal image correlation (4D BF-STIC) in detecting IAA type A (IAA-A). Twenty-three cases of confirmed IAA-A identified by fetal echocardiography were involved in the study. The fetal echocardiography image data were reviewed to analyze the ratio of right ventricle to left ventricle (RV/LV) diameter, the ratio of main pulmonary artery to ascending aorta (MPA/AAO) diameter, and the correlation of RV/LV diameter ratio and size of ventricular septal defect (VSD). 4D BF-STIC was performed in 21 fetuses using the sagittal view (4D BF-STIC-sagittal) and the four-chamber view (4D BF-STIC-4CV) as initial planes of view. An additional 183 normal fetuses were also included in our study. RV/LV and MPA/AAO ratios were calculated and compared with that of IAA-A fetuses. Fetal 2DE, 4D BF-STIC-sagittal, and 4D BF-STIC-4CV were used to visualize the aortic arch and its associated neck vessels. Six subgroups were evaluated according to gestational age. Fetal 2DE, 4D BF-STIC-sagittal, and 4D BF-STIC-4CV made the correct prenatal diagnosis of IAA-A in 19/23 (82.6%), 14/21 (66.7%), and 19/21 (90.5%) of patients, respectively. A significantly enlarged MPA combined with symmetric ventricles was found in the IAA-A fetuses, while the size of the VSD was negatively correlated with RV/LV ratio. 4D BF-STIC-sagittal and 4D BF-STIC-4CV were better than traditional 2D ultrasound in detecting the aortic arch and neck vessels between 17 and 28 gestational weeks and 29 to 40 gestational weeks in normal fetuses. It is demonstrated that IAA-A could be diagnosed by traditional fetal echocardiography, while 4D technique could better display the anatomic structure and the spatial relationships of the great arteries. Use of volume reconstruction may

  6. Echocardiography in the Era of Multimodality Cardiovascular Imaging

    Science.gov (United States)

    Shah, Benoy Nalin

    2013-01-01

    Echocardiography remains the most frequently performed cardiac imaging investigation and is an invaluable tool for detailed and accurate evaluation of cardiac structure and function. Echocardiography, nuclear cardiology, cardiac magnetic resonance imaging, and cardiovascular-computed tomography comprise the subspeciality of cardiovascular imaging, and these techniques are often used together for a multimodality, comprehensive assessment of a number of cardiac diseases. This paper provides the general cardiologist and physician with an overview of state-of-the-art modern echocardiography, summarising established indications as well as highlighting advances in stress echocardiography, three-dimensional echocardiography, deformation imaging, and contrast echocardiography. Strengths and limitations of echocardiography are discussed as well as the growing role of real-time three-dimensional echocardiography in the guidance of structural heart interventions in the cardiac catheter laboratory. PMID:23878804

  7. Effectiveness of Myocardial Contrast Echocardiography Quantitative Analysis during Adenosine Stress versus Visual Analysis before Percutaneous Therapy in Acute Coronary Pain: A Coronary Artery TIMI Grading Comparing Study

    Science.gov (United States)

    Yang, Lixia; Mu, Yuming; Quaglia, Luiz Augusto; Tang, Qi; Guan, Lina; Wang, Chunmei; Shih, Ming Chi

    2012-01-01

    The study aim was to compare two different stress echocardiography interpretation techniques based on the correlation with thrombosis in myocardial infarction (TIMI ) flow grading from acute coronary syndrome (ACS) patients. Forty-one patients with suspected ACS were studied before diagnostic coronary angiography with myocardial contrast echocardiography (MCE) at rest and at stress. The correlation of visual interpretation of MCE and TIMI flow grade was significant. The quantitative analysis (myocardial perfusion parameters: A, β, and A × β) and TIMI flow grade were significant. MCE visual interpretation and TIMI flow grade had a high degree of agreement, on diagnosing myocardial perfusion abnormality. If one considers TIMI flow grade <3 as abnormal, MCE visual interpretation at rest had 73.1% accuracy with 58.2% sensitivity and 84.2% specificity and at stress had 80.4% accuracy with 76.6% sensitivity and 83.3% specificity. The MCE quantitative analysis has better accuracy with 100% of agreement with different level of TIMI flow grading. MCE quantitative analysis at stress has showed a direct correlation with TIMI flow grade, more significant than the visual interpretation technique. Further studies could measure the clinical relevance of this more objective approach to managing acute coronary syndrome patient before percutaneous coronary intervention (PCI). PMID:22778555

  8. How to misuse echo contrast

    Directory of Open Access Journals (Sweden)

    Missios Anna

    2009-01-01

    Full Text Available Abstract Background Primary intracardiac tumours are rare, there are however several entities that can mimic tumours. Contrast echocardiography has been suggested to aid the differentiation of various suspected masses. We present a case where transthoracic echocardiography completely misdiagnosed a left atrial mass, partly due to use of echo contrast. Case presentation An 80 year-old woman was referred for transthoracic echocardiography because of one-month duration of worsening of dyspnoea. Transthoracic echocardiography displayed a large echodense mass in the left atrium. Intravenous injection of contrast (SonoVue, Bracco Inc., It indicated contrast-enhancement of the structure, suggesting tumour. Transesophageal echocardiography revealed, however, a completely normal finding in the left atrium. Subsequent gastroscopy examination showed a hiatal hernia. Conclusion It is noteworthy that the transthoracic echocardiographic exam completely misdiagnosed what seemed like a left atrial mass, which in part was an effect of the use of echo contrast. This example highlights that liberal use of transoesophageal echocardiography is often warranted if optimal display of cardiac structures is desired.

  9. Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography.

    Science.gov (United States)

    Shahgaldi, Kambiz; Gudmundsson, Petri; Manouras, Aristomenis; Brodin, Lars-Ake; Winter, Reidar

    2009-08-25

    Visual assessment of left ventricular ejection fraction (LVEF) is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS) measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing) is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE) and triplane echocardiography (TPE) using quantitative real-time three-dimensional echocardiography (RT3DE) as the reference method. Thirty patients were enrolled in the study. Eyeballing EF was assessed using apical 4-and 2 chamber views and TP mode by two experienced readers blinded to all clinical data. The measurements were compared to quantitative RT3DE. There were an excellent correlation between eyeballing EF by 2D and TP vs 3DE (r = 0.91 and 0.95 respectively) without any significant bias (-0.5 +/- 3.7% and -0.2 +/- 2.9% respectively). Intraobserver variability was 3.8% for eyeballing 2DE, 3.2% for eyeballing TP and 2.3% for quantitative 3D-EF. Interobserver variability was 7.5% for eyeballing 2D and 8.4% for eyeballing TP. Visual estimation of LVEF both using 2D and TP by an experienced reader correlates well with quantitative EF determined by RT3DE. There is an apparent trend towards a smaller variability using TP in comparison to 2D, this was however not statistically significant.

  10. Recent advances in echocardiography for nuclear medicine physician

    International Nuclear Information System (INIS)

    Hong, Geu Ru; Shin, Dong Gu

    2005-01-01

    Echocardiography is one of the most frequently used techniques for diagnosing cardiovascular diseases. Over the last twenty years, technological advances have enabled the application of high-quality imaging. Important recent developments have occurred in echocardiography that are already being used clinically. Equipment and hardware is now available to produce real time three-dimensional and contrast enhanced imaging. Tissue Doppler and stress echocardiography have provided potential benefit to analyze hemodynamic information of heart. This review discusses each of these new developments and their potential impact on the practice of echocardiography and cardiology in general

  11. Exact monitoring of aortic diameters in Marfan patients without gadolinium contrast: intraindividual comparison of 2D SSFP imaging with 3D CE-MRA and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Veldhoen, Simon [University Medical Center Wuerzburg, Department of Diagnostic and Interventional Radiology, Bavaria (Germany); University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Behzadi, Cyrus; Derlin, Thorsten; Henes, Frank Oliver; Adam, Gerhard; Bannas, Peter [University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Radiology, Hamburg (Germany); Rybczinsky, Meike; Kodolitsch, Yskert von; Sheikhzadeh, Sara [University Medical Center Hamburg-Eppendorf, Department of General and Interventional Cardiology, Hamburg (Germany); Bley, Thorsten Alexander [University Medical Center Wuerzburg, Department of Diagnostic and Interventional Radiology, Bavaria (Germany)

    2014-10-15

    To assess whether ECG-gated non-contrast 2D steady-state free precession (SSFP) imaging allows for exact monitoring of aortic diameters in Marfan syndrome (MFS) patients using non-ECG-gated contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and echocardiography for intraindividual comparison. Non-ECG-gated CE-MRA and ECG-gated non-contrast SSFP at 1.5 T were prospectively performed in 50 patients. Two readers measured aortic diameters on para-sagittal images identically aligned with the aortic arch at the sinuses of Valsalva, sinotubular junction, ascending/descending aorta and aortic arch. Image quality was assessed on a three-point scale. Aortic root diameters acquired by echocardiography were used as reference. Intra- and interobserver variances were smaller for SSFP at the sinuses of Valsalva (p = 0.002; p = 0.002) and sinotubular junction (p = 0.014; p = 0.043). Image quality was better in SSFP than in CE-MRA at the sinuses of Valsalva (p < 0.0001), sinotubular junction (p < 0.0001) and ascending aorta (p = 0.02). CE-MRA yielded higher diameters than SSFP at the sinuses of Valsalva (mean bias, 2.5 mm; p < 0.0001), and comparison with echocardiography confirmed a higher bias for CE-MRA (7.2 ± 3.4 mm vs. SSFP, 4.7 ± 2.6 mm). ECG-gated non-contrast 2D SSFP imaging provides superior image quality with higher validity compared to non-ECG-gated contrast-enhanced 3D imaging. Since CE-MRA requires contrast agents with potential adverse effects, non-contrast SSFP imaging is an appropriate alternative for exact and riskless aortic monitoring of MFS patients. (orig.)

  12. Exact monitoring of aortic diameters in Marfan patients without gadolinium contrast: intraindividual comparison of 2D SSFP imaging with 3D CE-MRA and echocardiography

    International Nuclear Information System (INIS)

    Veldhoen, Simon; Behzadi, Cyrus; Derlin, Thorsten; Henes, Frank Oliver; Adam, Gerhard; Bannas, Peter; Rybczinsky, Meike; Kodolitsch, Yskert von; Sheikhzadeh, Sara; Bley, Thorsten Alexander

    2015-01-01

    To assess whether ECG-gated non-contrast 2D steady-state free precession (SSFP) imaging allows for exact monitoring of aortic diameters in Marfan syndrome (MFS) patients using non-ECG-gated contrast-enhanced 3D magnetic resonance angiography (CE-MRA) and echocardiography for intraindividual comparison. Non-ECG-gated CE-MRA and ECG-gated non-contrast SSFP at 1.5 T were prospectively performed in 50 patients. Two readers measured aortic diameters on para-sagittal images identically aligned with the aortic arch at the sinuses of Valsalva, sinotubular junction, ascending/descending aorta and aortic arch. Image quality was assessed on a three-point scale. Aortic root diameters acquired by echocardiography were used as reference. Intra- and interobserver variances were smaller for SSFP at the sinuses of Valsalva (p = 0.002; p = 0.002) and sinotubular junction (p = 0.014; p = 0.043). Image quality was better in SSFP than in CE-MRA at the sinuses of Valsalva (p < 0.0001), sinotubular junction (p < 0.0001) and ascending aorta (p = 0.02). CE-MRA yielded higher diameters than SSFP at the sinuses of Valsalva (mean bias, 2.5 mm; p < 0.0001), and comparison with echocardiography confirmed a higher bias for CE-MRA (7.2 ± 3.4 mm vs. SSFP, 4.7 ± 2.6 mm). ECG-gated non-contrast 2D SSFP imaging provides superior image quality with higher validity compared to non-ECG-gated contrast-enhanced 3D imaging. Since CE-MRA requires contrast agents with potential adverse effects, non-contrast SSFP imaging is an appropriate alternative for exact and riskless aortic monitoring of MFS patients. (orig.)

  13. Visually estimated ejection fraction by two dimensional and triplane echocardiography is closely correlated with quantitative ejection fraction by real-time three dimensional echocardiography

    Directory of Open Access Journals (Sweden)

    Manouras Aristomenis

    2009-08-01

    Full Text Available Abstract Background Visual assessment of left ventricular ejection fraction (LVEF is often used in clinical routine despite general recommendations to use quantitative biplane Simpsons (BPS measurements. Even thou quantitative methods are well validated and from many reasons preferable, the feasibility of visual assessment (eyeballing is superior. There is to date only sparse data comparing visual EF assessment in comparison to quantitative methods available. The aim of this study was to compare visual EF assessment by two-dimensional echocardiography (2DE and triplane echocardiography (TPE using quantitative real-time three-dimensional echocardiography (RT3DE as the reference method. Methods Thirty patients were enrolled in the study. Eyeballing EF was assessed using apical 4-and 2 chamber views and TP mode by two experienced readers blinded to all clinical data. The measurements were compared to quantitative RT3DE. Results There were an excellent correlation between eyeballing EF by 2D and TP vs 3DE (r = 0.91 and 0.95 respectively without any significant bias (-0.5 ± 3.7% and -0.2 ± 2.9% respectively. Intraobserver variability was 3.8% for eyeballing 2DE, 3.2% for eyeballing TP and 2.3% for quantitative 3D-EF. Interobserver variability was 7.5% for eyeballing 2D and 8.4% for eyeballing TP. Conclusion Visual estimation of LVEF both using 2D and TP by an experienced reader correlates well with quantitative EF determined by RT3DE. There is an apparent trend towards a smaller variability using TP in comparison to 2D, this was however not statistically significant.

  14. Internal medicine point-of-care ultrasound assessment of left ventricular function correlates with formal echocardiography.

    Science.gov (United States)

    Johnson, Benjamin K; Tierney, David M; Rosborough, Terry K; Harris, Kevin M; Newell, Marc C

    2016-02-01

    Although focused cardiac ultrasonographic (FoCUS) examination has been evaluated in emergency departments and intensive care units with good correlation to formal echocardiography, accuracy for the assessment of left ventricular systolic function (LVSF) when performed by internal medicine physicians still needs independent evaluation. This prospective observational study in a 640-bed, academic, quaternary care center, included 178 inpatients examined by 10 internal medicine physicians who had completed our internal medicine bedside ultrasound training program. The ability to estimate LVSF with FoCUS as "normal," "mild to moderately decreased," or "severely decreased" was compared with left ventricular ejection fraction (>50%, 31-49%, and internal medicine physician-performed FoCUS and formal echocardiography for any LVSF impairment was "good/substantial" with κ = 0.77 (p Internal medicine physicians using FoCUS identify normal versus decreased LVSF with high sensitivity, specificity, and "good/substantial" interrater agreement when compared with formal echocardiography. These results support the role of cardiac FoCUS by properly trained internal medicine physicians for discriminating normal from reduced LVSF. © 2015 Wiley Periodicals, Inc.

  15. Modified Right Heart Contrast Echocardiography Versus Traditional Method in Diagnosis of Right-to-Left Shunt: A Comparative Study

    OpenAIRE

    Wang, Yi; Zeng, Jie; Yin, Lixue; Zhang, Mei; Hou, Dailun

    2016-01-01

    BACKGROUND: The purpose of this study was to evaluate the reliability, effectiveness, and safety of modified right heart contrast transthoracic echocardiography (cTTE) in comparison with the traditional method. MATERIAL AND METHODS: We performed a modified right heart cTTE using saline mixed with a small sample of patient's own blood. Samples were agitated with varying intensity. This study protocol involved microscopic analysis and patient evaluation. 1. Microscopic analysis: After two contr...

  16. Bioeffects of albumin-encapsulated microbubbles and real-time myocardial contrast echocardiography in an experimental canine model

    Directory of Open Access Journals (Sweden)

    P.M.M. Dourado

    2006-06-01

    Full Text Available Myocardial contrast echocardiography has been used for assessing myocardial perfusion. Some concerns regarding its safety still remain, mainly regarding the induction of microvascular alterations. We sought to determine the bioeffects of microbubbles and real-time myocardial contrast echocardiography (RTMCE in a closed-chest canine model. Eighteen mongrel dogs were randomly assigned to two groups. Nine were submitted to continuous intravenous infusion of perfluorocarbon-exposed sonicated dextrose albumin (PESDA plus continuous imaging using power pulse inversion RTMCE for 180 min, associated with manually deflagrated high-mechanical index impulses. The control group consisted of 3 dogs submitted to continuous imaging using RTMCE without PESDA, 3 dogs received PESDA alone, and 3 dogs were sham-operated. Hemodynamics and cardiac rhythm were monitored continuously. Histological analysis was performed on cardiac and pulmonary tissues. No hemodynamic changes or cardiac arrhythmias were observed in any group. Normal left ventricular ejection fraction and myocardial perfusion were maintained throughout the protocol. Frequency of mild and focal microhemorrhage areas in myocardial and pulmonary tissue was similar in PESDA plus RTMCE and control groups. The percentages of positive microscopical fields in the myocardium were 0.4 and 0.7% (P = NS in the PESDA plus RTMCE and control groups, respectively, and in the lungs they were 2.1 and 1.1%, respectively (P = NS. In this canine model, myocardial perfusion imaging obtained with PESDA and RTMCE was safe, with no alteration in cardiac rhythm or left ventricular function. Mild and focal myocardial and pulmonary microhemorrhages were observed in both groups, and may be attributed to surgical tissue manipulation.

  17. The history of echocardiography.

    Science.gov (United States)

    Edler, Inge; Lindström, Kjell

    2004-12-01

    Following a brief review of the development of medical ultrasonics from the mid-1930s to the mid-1950s, the collaboration between Edler and Hertz that began in Lund in 1953 is described. Using an industrial ultrasonic flaw detector, they obtained time-varying echoes transcutaneously from within the heart. The first clinical applications of M-mode echocardiography were concerned with the assessment of the mitral valve from the shapes of the corresponding waveforms. Subsequently, the various M-mode recordings were related to their anatomical origins. The method then became established as a diagnostic tool and was taken up by investigators outside Lund, initially in China, Germany, Japan and the USA and, subsequently, world-wide. The diffusion of echocardiography into clinical practice depended on the timely commercial availability of suitable equipment. The discovery of contrast echocardiography in the late 1960s further validated the technique and extended the range of applications. Two-dimensional echocardiography was first demonstrated in the late 1950s, with real-time mechanical systems and, in the early 1960s, with intracardiac probes. Transesophageal echocardiography followed, in the late 1960s. Stop-action two-dimensional echocardiography enjoyed a brief vogue in the early 1970s. It was, however, the demonstration by Bom in Rotterdam of real-time two-dimensional echocardiography using a linear transducer array that revolutionized and popularized the subject. Then, the phased array sector scanner, which had been demonstrated in the late 1960s by Somer in Utrecht, was applied to cardiac studies from the mid-1970s onwards. Satomura had demonstrated the use of the ultrasonic Doppler effect to detect tissue motion in Osaka in the mid-1950s and the technique was soon afterwards applied in the heart, often in combination with M-mode recording. The development of the pulsed Doppler method in the late 1960s opened up new opportunities for clinical innovation. The

  18. Pretest Score for Predicting Microbubble Contrast Agent Use in Stress Echocardiography: A Method to Increase Efficiency in the Echo Laboratory

    Directory of Open Access Journals (Sweden)

    Mathieu Bernier

    2009-01-01

    contrast. Logistic regression models were used to evaluate the association between individual characteristics and contrast use. An 11-point score was derived from the significant characteristics. Results. Variables associated with microbubble use were age, sex, smoking, presence of multiple risk factors, bodymass index (BMI, referral for dobutamine stress echocardiography, history of coronary artery disease, and abnormal baseline electrocardiogram. All variables except BMI were given a score of 1 if present and 0 if absent; BMI was given a score of 0 to 4 according to its value. An increased score was directly proportional to increased likelihood of contrast use. The score cutoff value to optimize sensitivity and specificity was 5. Conclusions. A pretest score can be computed from information available before imaging. It may facilitate contrast agent use through early identification of patients who are likely to benefit from improved endocardial border definition.

  19. Incremental value of contrast myocardial perfusion to detect intermediate versus severe coronary artery stenosis during stress-echocardiography

    Directory of Open Access Journals (Sweden)

    Ugo Fabrizio

    2010-05-01

    Full Text Available Abstract Background We aimed to compare the incremental value of contrast myocardial perfusion imaging (MPI for the detection of intermediate versus severe coronary artery stenosis during dipyridamole-atropine echocardiography (DASE. Wall motion (WM assessment during stress-echocardiography demonstrates suboptimal sensitivity to detect coronary artery disease (CAD, particularly in patients with isolated intermediate (50%-70% coronary stenosis. Methods We performed DASE with MPI in 150 patients with a suspected chest pain syndrome who were given clinical indication to coronary angiography. Results and discussion When CAD was defined as the presence of a ≥50% stenosis, the addition of MPI increased sensitivity (+30% and decreased specificity (-14%, with a final increase in total diagnostic accuracy (+16%, p Conclusions The addition of MPI on top of WM analysis during DASE increases the diagnostic sensitivity to detect obstructive CAD, whatever its definition (≥50% or > 70% stenosis, but it is mainly driven by the sensitivity increase in the intermediate group (50%-70% stenosis. The total diagnostic accuracy increased only when defining CAD as ≥50% stenosis, since in patients with severe stenosis (> 70% the decrease in specificity is not counterbalanced by the minor sensitivity increase.

  20. 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Gabbour, Maya [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Schnell, Susanne [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Jarvis, Kelly [Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Robinson, Joshua D. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Pediatrics, Division of Pediatric Cardiology, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Pediatrics, Chicago, IL (United States); Markl, Michael [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States)

    2015-06-15

    Doppler echocardiography (echo) is the reference standard for blood flow velocity analysis, and two-dimensional (2-D) phase-contrast magnetic resonance imaging (MRI) is considered the reference standard for quantitative blood flow assessment. However, both clinical standard-of-care techniques are limited by 2-D acquisitions and single-direction velocity encoding and may make them inadequate to assess the complex three-dimensional hemodynamics seen in congenital heart disease. Four-dimensional flow MRI (4-D flow) enables qualitative and quantitative analysis of complex blood flow in the heart and great arteries. The objectives of this study are to compare 4-D flow with 2-D phase-contrast MRI for quantification of aortic and pulmonary flow and to evaluate the advantage of 4-D flow-based volumetric flow analysis compared to 2-D phase-contrast MRI and echo for peak velocity assessment in children and young adults. Two-dimensional phase-contrast MRI of the aortic root, main pulmonary artery (MPA), and right and left pulmonary arteries (RPA, LPA) and 4-D flow with volumetric coverage of the aorta and pulmonary arteries were performed in 50 patients (mean age: 13.1 ± 6.4 years). Four-dimensional flow analyses included calculation of net flow and regurgitant fraction with 4-D flow analysis planes similarly positioned to 2-D planes. In addition, 4-D flow volumetric assessment of aortic root/ascending aorta and MPA peak velocities was performed and compared to 2-D phase-contrast MRI and echo. Excellent correlation and agreement were found between 2-D phase-contrast MRI and 4-D flow for net flow (r = 0.97, P < 0.001) and excellent correlation with good agreement was found for regurgitant fraction (r = 0.88, P < 0.001) in all vessels. Two-dimensional phase-contrast MRI significantly underestimated aortic (P = 0.032) and MPA (P < 0.001) peak velocities compared to echo, while volumetric 4-D flow analysis resulted in higher (aortic: P = 0.001) or similar (MPA: P = 0.98) peak

  1. Differences in aortic vortex flow pattern between normal and patients with stroke: qualitative and quantitative assessment using transesophageal contrast echocardiography.

    Science.gov (United States)

    Son, Jang-Won; Hong, Geu-Ru; Hong, Woosol; Kim, Minji; Houle, Helene; Vannan, Mani A; Pedrizzetti, Gianni; Chung, Namsik

    2016-06-01

    The flow in the aorta forms a vortex, which is a critical determinant of the flow dynamics in the aorta. Arteriosclerosis can alter the blood flow pattern of the aorta and cause characteristic alterations of the vortex. However, this change in aortic vortex has not yet been studied. This study aimed to characterize aortic vortex flow pattern using transesophageal contrast echocardiography in normal and stroke patients. A total of 85 patients who diagnosed with ischemic stroke and 16 normal controls were recruited for this study. The 16 normal control subjects were designated as the control group, and the 85 ischemic stroke patients were designated as the stroke group. All subjects underwent contrast transesophageal echocardiography (TEE), and particle image velocimetry was used to assess aortic vortex flow. Qualitative and quantitative analyses of vortex flow morphology, location, phasic variation, and pulsatility were undertaken and compared between the groups. In the control group, multiple irregularly-shaped vortices were observed in a peripheral location in the descending thoracic aorta. In contrast, the stroke group had a single, round, merged, and more centrally located aortic vortex flow. In the quantitative analysis of vortex, vortex depth, which represents the location of the major vortex in the aorta, was significantly higher in the control group than in the stroke group (0.599 ± 0.159 vs. 0.522 ± 0.101, respectively, P = 0.013). Vortex relative strength, which is the pulsatility parameter of the vortex itself, was significantly higher in the stroke group than in the control group (0.367 ± 0.148 vs. 0.304 ± 0.087, respectively, P = 0.025). It was feasible to visualize and quantify the characteristic morphology and pulsatility of the aortic vortex flow using contrast TEE, and aortic vortex pattern significantly differed between normal and stroke patients.

  2. Novel techniques in stress echocardiography: a focus on the advantages and disadvantages.

    Science.gov (United States)

    Vamvakidou, Anastasia; Gurunathan, Sothinathan; Senior, Roxy

    2016-01-01

    Stress echocardiography (SE) is an established tool not only for the assessment of coronary artery disease (CAD), but also for the evaluation of valvular disease and cardiomyopathy. New techniques, namely contrast echocardiography for function and perfusion including assessment of coronary flow reserve, strain imaging, 3-dimensional echocardiography, Doppler-derived coronary flow reserve and multimodality echocardiography, have been incorporated into stress protocols for improving assessment of cardiac disease. In this review, the advantages and disadvantages of these novel SE techniques are examined in terms of feasibility, accuracy, reproducibility and applications.

  3. Intra-cardiac echocardiography in alcohol septal ablation

    DEFF Research Database (Denmark)

    Cooper, Robert M; Shahzad, Adeel; Newton, James

    2015-01-01

    Alcohol septal ablation (ASA) in hypertrophic obstructive cardiomyopathy reduces left ventricular outflow tract gradients. A third of patients do not respond; inaccurate localisation of the iatrogenic infarct can be responsible. Transthoracic echocardiography (TTE) using myocardial contrast can...

  4. Correlation Between Doppler Echocardiography and Right Heart Catheterization Derived Pulmonary Artery Pressures: Impact of Right Atrial Pressures

    International Nuclear Information System (INIS)

    Ahmed, I.; Nuri, M. M. H.; Zakariyya, A. N.; Ahmad, S. M.; Ahmed, M.

    2016-01-01

    Objective: To evaluate the correlation between Doppler echocardiography (DE) and right heart catheterization (RHC) derived pulmonary artery pressures and to assess the impact of right atrial (RA) pressures on this correlation. Study Design: Cross-sectional analytical study. Place and Duration of Study: Cardiology Department, Tahir Heart Institute, Chenab Nagar, from June 2013 to December 2014. Methodology: All patients undergoing RHC were included. Relevant data were collected from hospital database. Continuous variables were expressed as the mean and SD or as the median and interquartile range where the distributions were skewed. Pearson correlation coefficient and Bland-Altman method were used to correlate DE derived right ventricular systolic pressure (RVSP) and RHC derived systolic pulmonary artery pressures (sPAP). Adjusted RVSP was calculated by replacing default value of RA pressure (10 mmHg) with RHC derived mean RA pressure. Receiver operating characteristic curve (ROC) was used to identify the best cut-off value of RVSP in predicting pulmonary hypertension. Results: Fifty-one patients completed the study protocol. Mean age of study population was 45.22 ± 15.25 years with male to female ratio of 1.47:1. Median error was 13 mmHg (7 to 20). Pearson correlation coefficient (r) between RVSP and sPAP was 0.72. Bland-Altman method of correlation showed bias of +4.43 mmHg with 95% limits of agreement ranging from -34.61 to +43.47. Using ROC curve, the best cut-off value of RVSP was greater than 52 mmHg with accuracy of 75% (sensitivity: 81%, specificity: 69%) in predicting pulmonary hypertension. Adjusted RVSP showed only little improvement in correlation (r = 0.75), adjusted error (13.65 ± 13.05) and diagnostic accuracy (79%). Conclusion: Doppler echocardiography can frequently overestimate pulmonary artery pressures. Though correctly estimated RA pressure may improve this correlation, yet its contribution is only minimal. (author)

  5. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    DEFF Research Database (Denmark)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel

    2018-01-01

    ) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. RESULTS: 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D...... echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different...... between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r

  6. Echocardiography as an indication of continuous-time cardiac quiescence

    Science.gov (United States)

    Wick, C. A.; Auffermann, W. F.; Shah, A. J.; Inan, O. T.; Bhatti, P. T.; Tridandapani, S.

    2016-07-01

    Cardiac computed tomography (CT) angiography using prospective gating requires that data be acquired during intervals of minimal cardiac motion to obtain diagnostic images of the coronary vessels free of motion artifacts. This work is intended to assess B-mode echocardiography as a continuous-time indication of these quiescent periods to determine if echocardiography can be used as a cost-efficient, non-ionizing modality to develop new prospective gating techniques for cardiac CT. These new prospective gating approaches will not be based on echocardiography itself but on CT-compatible modalities derived from the mechanics of the heart (e.g. seismocardiography and impedance cardiography), unlike the current standard electrocardiogram. To this end, echocardiography and retrospectively-gated CT data were obtained from ten patients with varied cardiac conditions. CT reconstructions were made throughout the cardiac cycle. Motion of the interventricular septum (IVS) was calculated from both echocardiography and CT reconstructions using correlation-based, deviation techniques. The IVS was chosen because it (1) is visible in echocardiography images, whereas the coronary vessels generally are not, and (2) has been shown to be a suitable indicator of cardiac quiescence. Quiescent phases were calculated as the minima of IVS motion and CT volumes were reconstructed for these phases. The diagnostic quality of the CT reconstructions from phases calculated from echocardiography and CT data was graded on a four-point Likert scale by a board-certified radiologist fellowship-trained in cardiothoracic radiology. Using a Wilcoxon signed-rank test, no significant difference in the diagnostic quality of the coronary vessels was found between CT volumes reconstructed from echocardiography- and CT-selected phases. Additionally, there was a correlation of 0.956 between the echocardiography- and CT-selected phases. This initial work suggests that B-mode echocardiography can be used as a

  7. Diagnostic value of echocardiography in infective endocarditis

    International Nuclear Information System (INIS)

    Luo Yinli; Ni Xianda; Hu Yuanping; Liu Jingyun; Yang Weiyu

    2010-01-01

    Objective: To investigate the feature and value of echocardiography for diagnosing infective endocarditis. Methods: The shape, size, echogenicity, distribution of vegetations and valvular injury of the heart were observed in 30 patients with infective endocarditis. Results: The vegetations were located in the aortic valves (10 cases), bicuspid valves (5), tricuspid valve (1), pulmonary valve (2), main pulmonary artery with patent ductus arteriosus (2), and right ventricle with ventricular septal defect (2). The size of vegetation ranged from 2 to 27 mm and the echogenicity of vegetations was low to high. The location, size, shape and amount of vegetations observed on echocardiography correlated well with the operative findings. Echocardiography also demonstrated underlying heart disease and abnormal hemodynamics induced by infective endocarditis. Conclusion: Echocardiography can determine the location, size, shape, amount of vegetation and concomitant cardiac disease in patients with infective endocarditis. It play an important role in treatment and prognosis. (authors)

  8. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    Science.gov (United States)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel; Tayal, Bhupendar; Solty, Kilian; Laufs, Ulrich; Pfeiffer, Dietrich; Hagendorff, Andreas

    2018-01-01

    Purpose The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. Methods Left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. Results 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r echocardiography and 2D echocardiography/cMRI and good agreement was observed between 3D echocardiography/cMRI. Conclusion Semi-quantitative parameters are difficult to determine by 2D echocardiography in clinical routine. The quantitative volumetric RF assessment seems to be feasible and can be discussed as an alternative approach in chronic AR. However, RVol and RF did not correlate well between the different imaging modalities. The best agreement for grading of AR severity by RF was observed between 3D echocardiography and cMRI. LV volumes can be verified by different approaches and different imaging modalities. PMID:29519957

  9. Study of Coronary Flow Reserve with Intravenous Use of Microbubbles (Contrast Echocardiography and Adenosine: Protocol for Clinical Application in Patients Suspected of Having Coronary Heart Disease

    Directory of Open Access Journals (Sweden)

    Morcerf Fernando

    2002-01-01

    Full Text Available OBJECTIVE: To test the feasibility, safety and accuracy of the adenosine protocol in the study of myocardial perfusion with microbubbles contrast echocardiography. METHODS: 81 pts (64 male, 60+11 years were submitted to contrast echocardiography with PESDA (sonicated solution of albumin 20%-1ml, dextrose 5%-12ml and deca-fluorobutane gas-8ml to study the myocardial perfusion at rest and after bolus injection of adenosine (6 to 18mg and to coronary angiography within 1 month each other. For each patient 3 left ventricle perfusion beds were considered (total of 243 territories. 208 territories were analyzed and 35 territories were excluded. PESDA was continuously infused (1-2ml/min, titrated for best myocardial contrast. Triggered (1:1 second harmonic imaging was used. RESULTS: Coronary angiography showed 70 flow limiting (> 75% lesions and 138 no flow limiting lesions. At rest an obvious myocardium contrast enhancement was seen in at least 1 segment of a territory in all patients. After adenosine injection an unquestionable further increase in myocardial contrast was observed in 136 territories (99% related to no flow limiting lesions, lasting < 10 s, and a myocardial perfusion defect was detected in 68 territories (97% related to flow limiting lesions. It was observed only 4 false results. There were no serious complications. CONCLUSION: Myocardial perfusion study with PESDA and adenosine protocol is a practical, safe and accurate method to analyze the coronary flow reserve.

  10. [Effect of the use of echoenhancers on interobserver variability in dobutamine stress echocardiography].

    Science.gov (United States)

    Zamorano, J L; Sánchez, V; Almería, C; Serra, V; Rodrigo, J L; Sánchez-Harguindey, L

    2000-10-01

    Dobutamine stress echocardiography is an accurate technique for the noninvasive diagnosis of coronary artery disease. However, interobserver variability is an important limitation of stress echocardiography. Image quality and echocardiographer experience have been described to influence interobserver agreement. The aim of this study was to determine whether use of contrast agents during dobutamine stress echocardiography improves the agreement between an experienced and a unexperienced observer, and if learning period would be influenced by the use of contrast. Two blind observers interpreted all the studies: one experienced echocardiographer (A) and one unexperienced observer (B) in this technique. The contrast agent Levovist/Levograf 2.5 g was administered by two bolus (at rest and at peak stress). In all cases, second harmonic imaging and stress digitalisation packs were used. The kappa test was used to determine interobserver agreement. Fifty-two unselected consecutive studies in 51 patients were analyzed. Twenty-two studies were performed with contrast. The agreement between the experienced and the unexperienced observer was Kappa 0.58 and 0.52, with and without the use of contrast, with no statistically significant difference being archived. The routine use of contrast provides better although not significant, interobserver agreement. However, this improvement is not sufficient to substitute specific training.

  11. Correlation of two-dimensional echocardiography and pathologic findings in porcine valve dysfunction.

    Science.gov (United States)

    Forman, M B; Phelan, B K; Robertson, R M; Virmani, R

    1985-02-01

    Two-dimensional echocardiographic findings in porcine valve dysfunction were compared with pathologic findings in 10 patients (12 valves). Three specific echocardiographic findings were identified in patients with regurgitant lesions: prolapse, fracture and flail leaflets. Prolapse was associated pathologically with thinning of the leaflets, longitudinal tears close to the ring margin and acid mucopolysaccharide accumulation. Valve fracture was seen with and without prolapse and was accompanied pathologically by small pinpoint perforations or tears of the leaflet. A flail leaflet was seen with a linear tear of the free margin and was associated with calcific deposits. Mild degrees of fracture seen pathologically were missed on the echocardiographic study in five patients. Thickening or calcification, when present in moderate or severe amounts, was correctly identified by echocardiography. When all abnormal features were considered collectively, two-dimensional echocardiography correctly identified at least one of them in all patients. Therefore, two-dimensional echocardiography may prove useful in assessing the source of valvular regurgitation in patients with bioprosthetic valves.

  12. Potential of right to left ventricular volume ratio measured on chest CT for the prediction of pulmonary hypertension: correlation with pulmonary arterial systolic pressure estimated by echocardiography

    International Nuclear Information System (INIS)

    Lee, Heon; Kim, Seok Yeon; Lee, Soo Jeong; Kim, Jae Kyun; Reddy, Ryan P.; Schoepf, U.J.

    2012-01-01

    To investigate the correlation of right ventricular (RV) to left ventricular (LV) volume ratio measured by chest CT with pulmonary arterial systolic pressure (PASP) estimated by echocardiography. 104 patients (72.47 ± 13.64 years; 39 male) who had undergone chest CT and echocardiography were divided into two groups (hypertensive and normotensive) based upon an echocardiography-derived PASP of 25 mmHg. RV to LV volume ratios (RV V /LV V ) were calculated. RV V /LV V was then correlated with PASP using regression analysis. The Area Under the Curve (AUC) for predicting pulmonary hypertension on chest CT was calculated. In the hypertensive group, the mean PASP was 46.29 ± 14.42 mmHg (29-98 mmHg) and there was strong correlation between the RV V /LV V and PASP (R = 0.82, p V /LV V were 0.990 and 0.892. RV V /LV V was 1.01 ± 0.44 (0.51-2.77) in the hypertensive and 0.72 ± 0.14 (0.52-1.11) in the normotensive group (P V /LV V , sensitivity and specificity for predicting pulmonary hypertension over 40 mmHg were 79.5 % and 90 %, respectively. The AUC for predicting pulmonary hypertension was 0.87 RV/LV volume ratios on chest CT correlate well with PASP estimated by echocardiography and can be used to predict pulmonary hypertension over 40 mmHg with high sensitivity and specificity. (orig.)

  13. Abnormal myocardial capillary density in apical hypertrophic cardiomyopathy can be assessed by myocardial contrast echocardiography

    International Nuclear Information System (INIS)

    Moon, Jeonggeun; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Jang, Yangsoo; Chung, Namsik; Rim, Se-Joong

    2010-01-01

    Myocardial ischemia and dysfunction can occur in hypertrophic cardiomyopathy (HCM) because of the high muscle-to-blood ratio, even without significant coronary artery disease. Microbubbles reside only in the intravascular space and myocardial video-intensity during systole results mostly from microbubbles within capillaries. The hypothesis explored in the present study was that an abnormal capillary density in apical HCM (ApHCM) can be demonstrated using myocardial contrast echocardiography (MCE). The 56 patients were investigated (31 males, age 58±9 years; 33 ApHCM, 9 hypertensive left ventricular hypertrophy [LVH], 14 controls). MCE was performed with low-mechanical-index power modulation imaging. Tissue Doppler imaging to assess myocardial contractile function was obtained at the mitral annulus (S'), and 99m Tc-MIBI single photon emission computed tomography (SPECT) was also performed. All ApHCM patients exhibited perfusion defects at the hypertrophied segments in the systolic phase during MCE, whereas SPECT showed normal or rather increased perfusion at those sites. The cyclic variation of video-intensity was exaggerated in ApHCM when compared with the LVH or control group (% of [systolic video-intensity]/[diastolic video-intensity]: 33.0±12.3%, 88.3±19.2% and 79.4±13.9%, respectively [P<0.05]). Concurrently, MCE cyclic variation and perfusion defect size were related to decreased S' (P<0.05 for all). A perfusion defect at the hypertrophied segment, representing abnormal myocardial capillary density, was observed in ApHCM patients during MCE. The extent of MCE cyclic variation and the perfusion defect size both correlate with decreased myocardial contractile property in ApHCM. (author)

  14. What Is Echocardiography?

    Science.gov (United States)

    ... Intramural Research Home / Echocardiography Echocardiography Also known as Echo , Surface echo , Ultrasound of ... other tests, echo doesn't involve radiation. Transthoracic Echocardiography Transthoracic (tranz-thor-AS-ik) echo is the ...

  15. Potential of right to left ventricular volume ratio measured on chest CT for the prediction of pulmonary hypertension: correlation with pulmonary arterial systolic pressure estimated by echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Heon [Soon Chun Hyang University, Department of Radiology, Bucheon (Korea, Republic of); Kim, Seok Yeon [Seoul Medical Center, Department of Cardiology, Seoul (Korea, Republic of); Lee, Soo Jeong [Terarecon Korea, Seoul (Korea, Republic of); Kim, Jae Kyun [Chung-Ang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Reddy, Ryan P.; Schoepf, U.J. [Medical University of South Carolina, Department of Radiology and Radiological Science and Division of Cardiology, Department of Medicine, Charleston, SC (United States)

    2012-09-15

    To investigate the correlation of right ventricular (RV) to left ventricular (LV) volume ratio measured by chest CT with pulmonary arterial systolic pressure (PASP) estimated by echocardiography. 104 patients (72.47 {+-} 13.64 years; 39 male) who had undergone chest CT and echocardiography were divided into two groups (hypertensive and normotensive) based upon an echocardiography-derived PASP of 25 mmHg. RV to LV volume ratios (RV{sub V}/LV{sub V}) were calculated. RV{sub V}/LV{sub V} was then correlated with PASP using regression analysis. The Area Under the Curve (AUC) for predicting pulmonary hypertension on chest CT was calculated. In the hypertensive group, the mean PASP was 46.29 {+-} 14.42 mmHg (29-98 mmHg) and there was strong correlation between the RV{sub V}/LV{sub V} and PASP (R = 0.82, p < 0.001). The intraobserver and interobserver correlation coefficients for RV{sub V}/LV{sub V} were 0.990 and 0.892. RV{sub V}/LV{sub V} was 1.01 {+-} 0.44 (0.51-2.77) in the hypertensive and 0.72 {+-} 0.14 (0.52-1.11) in the normotensive group (P <0.05). With 0.9 as the cutoff for RV{sub V}/LV{sub V}, sensitivity and specificity for predicting pulmonary hypertension over 40 mmHg were 79.5 % and 90 %, respectively. The AUC for predicting pulmonary hypertension was 0.87 RV/LV volume ratios on chest CT correlate well with PASP estimated by echocardiography and can be used to predict pulmonary hypertension over 40 mmHg with high sensitivity and specificity. (orig.)

  16. Evaluation of Left Atrial Volumes Using Multidetector Computed Tomography: Comparison with Echocardiography

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Kim, Sang Jin; Kim, Tae Hoon; Lee, Sang Min; Hong, Yoo Jin; Rim, Se Joong

    2010-01-01

    To prospectively assess the relationship between the two different measurement methods for the evaluation of left atrial (LA) volume using cardiac multidetector computed tomography (MDCT) and to compare the results between cardiac MDCT and echocardiography. Thirty-five patients (20 men, 15 women; mean age, 60 years) underwent cardiac MDCT angiography for coronary artery disease. The LA volumes were measured using two different methods: the two dimensional (2D) length-based (LB) method measured along the three-orthogonal planes of the LA and the 3D volumetric threshold-based (VTB) method measured according to the threshold 3D segmentation of the LA. The results obtained by cardiac MDCT were compared with those obtained by echocardiography. The LA end-systolic and end-diastolic volumes (LAESV and LAEDV) measured by the 2D-LB method correlated well with those measured by the 3DVTB method using cardiac MDCT (r = 0.763, r = 0.786, p = 0.001). However, there was a significant difference in the LAESVs between the two measurement methods using cardiac MDCT (p < 0.05). The LAESV measured by cardiac MDCT correlated well with measurements by echocardiography (r = 0.864, p = 0.001), however with a significant difference (p < 0.01) in their volumes. The cardiac MDCT overestimated the LAESV by 22% compared to measurements by echocardiography. A significant correlation was found between the two different measurement methods for evaluating LA volumes by cardiac MDCT. Further, cardiac MDCT correlates well with echocardiography in evaluating the LA volume. However, there are significant differences in the LAESV between the two measurement methods using cardiac MDCT and between cardiac MDCT and echocardiography

  17. Determination of the optimum number of cardiac cycles to differentiate intra-pulmonary shunt and patent foramen ovale by saline contrast two- and three-dimensional echocardiography.

    Science.gov (United States)

    Bhatia, Nirmanmoh; Abushora, Mohannad Y; Donneyong, Macarius M; Stoddard, Marcus F

    2014-03-01

    Patent foramen ovale (PFO) and intra-pulmonary shunt (IPS) are potential causes of stroke. The most optimum cardiac cycle cutoff for bubbles to appear in the left heart on saline contrast transthoracic echocardiography (TTE) as criteria to differentiate the 2 entities is unknown. Ninety-five adult patients had saline contrast transesophageal echocardiography (TEE), two-dimensional (2D) and 3DTTE. Sensitivity and specificity of each cardiac cycle as cutoff to differentiate a PFO and IPS were obtained. Transesophageal echocardiography showed IPS in 28 and PFO in 15 patients. If bubbles appeared in the left heart within the first 4 cardiac cycles (the 4th cardiac cycle rule) as compared to alternate cutoffs, a PFO was most accurately diagnosed by both 2D and 3DTTE. Bubbles appearing at or after the 5th cardiac cycle most accurately determined an IPS. 3D versus 2DTTE had a trend for a higher sensitivity (61% vs. 36%, P = 0.06), but similar specificity (94% vs. 91%) for IPS. Accuracy of 3DTTE was 84% and 2DTTE was 75% (P = 0.08) for IPS. For PFO, 2DTTE sensitivity (87%) and specificity (98%) did not differ (P = NS) from that of 3DTTE sensitivity (73%) and specificity (100%). This study demonstrates for the first time that the 4th cardiac cycle rule differentiates PFO and IPS most optimally by 2D and 3DTTE. 3DTTE appears to have higher sensitivity for diagnosing IPS. These data suggest that 3DTTE is preferable when IPS is to be diagnosed. Both methods are similar for diagnosing PFO. © 2013, Wiley Periodicals, Inc.

  18. Fetal echocardiography

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007340.htm Fetal echocardiography To use the sharing features on this page, please enable JavaScript. Fetal echocardiography is a test that uses sound waves ( ultrasound ) ...

  19. Assessment of left ventricular wall motion and function by cross-sectional echocardiography

    International Nuclear Information System (INIS)

    Ono, Akifumi; Hirata, Shunkichi; Ishikawa, Kyozo

    1982-01-01

    The clinical efficacy of cross-sectional echocardiography (CSE) was evaluated with M-mode echocardiography and radionuclide cardioangiography (RCG) in 50 cases including 30 patients with myocardial infarction. Segmental wall motion by CSE was highly correlated with segmental wall motion and left ventricular ejection fraction by RCG (r = 0.89 in the former, r = -0.84 in the latter). On the other hand, the left ventricular ejection fraction by M-mode echocardiography revealed a fairly well correlation with that by RCG ( r = 0.68). These results suggest that, as compared with RCG, CSE is quite useful in an evaluation of left ventricular function and in a detection of segmental wall motion abnormalities. (author)

  20. Correlation of 64 row MDCT, echocardiography and cardiac catheterization angiography in assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease

    International Nuclear Information System (INIS)

    Chandrashekhar, Guruprasadh; Sodhi, Kushaljit Singh; Saxena, Akshay Kumar; Rohit, Manoj Kumar; Khandelwal, Niranjan

    2012-01-01

    Objective: To study the correlation of low-dose 64-row multi-detector computed tomography (MDCT) with echocardiography and cardiac catheterization angiography (CCA) in the assessment of pulmonary arterial anatomy in children with cyanotic congenital heart disease (CCHD). Materials and methods: This prospective study included 105 children (74 males, 31 females) with CCHD, in the age group of 2 months to 20 years, who underwent 64-row MDCT examination (low-dose CT protocol), echocardiography and CCA for the assessment of pulmonary arteries, including visualization, presence of confluence, stenosis and collaterals. Statistical analysis was performed using the non-parametric statistical analysis test to evaluate the concordance or discordance between echocardiography, MDCT and CCA. Results: 64-row MDCT detected significantly more main and branch pulmonary arteries, patent pulmonary confluences, and more cases of pulmonary artery stenosis. CCA detected more major aorto-pulmonary collaterals than MDCT, whereas echocardiography failed to identify these major aorto-pulmonary collaterals. The effective CT radiation dose to patients less than 2 years of age was in the range of 0.7–2.5 mSv, where as the dose in patients more than 2 years of age ranged from that of 2.1 to 4.2 mSv, which is much less than the radiation dose reported in cardiac catheterization angiography. Conclusion: In cases where cardiac MRI cannot be performed, or is not sufficiently informative, low-dose 64-row MDCT correlates well with CCA and can provide adequate information about pulmonary arterial anatomy in children with cyanotic congenital heart disease, and can replace invasive cardiac catheterization angiography with markedly reduced radiation dosage to the patient.

  1. Fibroadenomas of the breast: histopathological/dynamic contrast-enhanced MR correlation

    Energy Technology Data Exchange (ETDEWEB)

    Gilles, R. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Garnier, C. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Meingan, P. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Zemoura, L. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Lucidarme, O. [Dept. of Radiology, Hopital Salpetriere, 75 - Paris (France); Guinebretiere, J.M. [Dept. of Histopathology C, Inst. Gustave Roussy, 94 - Villejuif (France); Tardivon, A.A. [Dept. of Radiology, Inst. Gustave Roussy, 94 - Villejuif (France)]|[CIERM, Hopital Bicetre, 94 - Le Kremin-Bicetre (France); Arriagada, R. [Breast Cancer Study Group, Inst. Gustave Roussy, 94 - Villejuif, (France)

    1995-12-31

    A total of 22 women with fibroadenomas had preoperative dynamic MR study (T1-weighted images every 47 s after injection of Gd-DOTA). Their age, hormonal status, breast MR studies and histopathological slides were retrospectively reviewed. Eleven pre- (n = 2) or post-menopausal (n = 9) women showed no early contrast enhancement. The absence of early contrast enhancement correlated with hyalin stromal component. Eleven pre- (n = 7) or post-menopausal (n = 4) women showed focal (n = 9) or diffuse (n = 2) early contrast enhancement. Early focal contrast enhancement correlated with myxoid (n = 9), mixed hyalin/myxoid (n = 1) or hyalin (n = 1) fibroadenomas. Early diffuse contrast enhancement of the breast correlated with myxoid (n = 1) or hyalin (n = 1) stromal component associated with proliferative fibrocystic disease of the breast parenchyma. The presence of contrast enhancement correlated with myxoid fibroadenomas, whereas absence of contrast enhancement correlated with hyalin fibroadenomas. As hyalin fibroadenomas occurs in post-menopausal women, the diagnostic accuracy of dynamic MRI may be improved in this age group. (orig.)

  2. Fibroadenomas of the breast: histopathological/dynamic contrast-enhanced MR correlation

    International Nuclear Information System (INIS)

    Gilles, R.; Garnier, C.; Meingan, P.; Zemoura, L.; Lucidarme, O.; Guinebretiere, J.M.; Tardivon, A.A.; Arriagada, R.

    1995-01-01

    A total of 22 women with fibroadenomas had preoperative dynamic MR study (T1-weighted images every 47 s after injection of Gd-DOTA). Their age, hormonal status, breast MR studies and histopathological slides were retrospectively reviewed. Eleven pre- (n = 2) or post-menopausal (n = 9) women showed no early contrast enhancement. The absence of early contrast enhancement correlated with hyalin stromal component. Eleven pre- (n = 7) or post-menopausal (n = 4) women showed focal (n = 9) or diffuse (n = 2) early contrast enhancement. Early focal contrast enhancement correlated with myxoid (n = 9), mixed hyalin/myxoid (n 1) or hyalin (n = 1) fibroadenomas. Early diffuse contrast enhancement of the breast correlated with myxoid (n = 1) or hyalin (n = 1) stromal component associated with proliferative fibrocystic disease of the breast parenchyma. The presence of contrast enhancement correlated with myxoid fibroadenomas, whereas absence of contrast enhancement correlated with hyalin fibroadenomas. As hyalin fibroadenomas occurs in post-menopausal women, the diagnostic accuracy of dynamic MRI may be improved in this age group. (orig.)

  3. Speckle tracking echocardiography in acute lupus myocarditis: comparison to conventional echocardiography

    Directory of Open Access Journals (Sweden)

    Riëtte Du Toit

    2017-07-01

    Full Text Available Aims: Lupus myocarditis occurs in 5–10% of patients with systemic lupus erythematosus (SLE. No single feature is diagnostic of lupus myocarditis. Speckle tracking echocardiography (STE can detect subclinical left ventricular dysfunction in SLE patients, with limited research on its utility in clinical lupus myocarditis. We report on STE in comparison to conventional echocardiography in patients with clinical lupus myocarditis. Methods and results: A retrospective study was done at a tertiary referral hospital in South Africa. SLE patients with lupus myocarditis were included and compared to healthy controls. Echocardiographic images were reanalyzed, including global longitudinal strain through STE. A poor echocardiographic outcome was defined as final left ventricular ejection fraction (LVEF <40%. 28 SLE patients fulfilled the criteria. Global longitudinal strain correlated with global (LVEF: r = −0.808; P = 0.001 and regional (wall motion score: r = 0.715; P < 0.001 function. In patients presenting with a LVEF ≥50%, global longitudinal strain (P = 0.023, wall motion score (P = 0.005 and diastolic function (P = 0.004 were significantly impaired vs controls. Following treatment, LVEF (35–47% (P = 0.023 and wall motion score (1.88–1.5 (P = 0.017 improved but not global longitudinal strain. Initial LVEF (34%; P = 0.046 and global longitudinal strain (−9.5%; P = 0.095 were lower in patients with a final LVEF <40%. Conclusions: This is the first known report on STE in a series of patients with clinical lupus myocarditis. Global longitudinal strain correlated with regional and global left ventricular function. Global longitudinal strain, wall motion score and diastolic parameters may be more sensitive markers of lupus myocarditis in patients presenting with a preserved LVEF ≥50%. A poor initial LVEF and global longitudinal strain were associated with a persistent LVEF <40%. Echocardiography is a non-invasive tool with diagnostic and

  4. Role of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation in detecting fetal pulmonary veins.

    Science.gov (United States)

    Sun, Xue; Zhang, Ying; Fan, Miao; Wang, Yu; Wang, Meilian; Siddiqui, Faiza Amber; Sun, Wei; Sun, Feifei; Zhang, Dongyu; Lei, Wenjia; Hu, Guyue

    2017-06-01

    Prenatal diagnosis of fetal total anomalous pulmonary vein connection (TAPVC) remains challenging for most screening sonographers. The purpose of this study was to evaluate the use of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation (4D-HDFI) in identifying pulmonary veins in normal and TAPVC fetuses. We retrospectively reviewed and performed 4D-HDFI in 204 normal and 12 fetuses with confirmed diagnosis of TAPVC. Cardiac volumes were available for postanalysis to obtain 4D-rendered images of the pulmonary veins. For the normal fetuses, two other traditional modalities including color Doppler and HDFI were used to detect the number of pulmonary veins and comparisons were made between each of these traditional methods and 4D-HDFI. For conventional echocardiography, HDFI modality was superior to color Doppler in detecting more pulmonary veins in normal fetuses throughout the gestational period. 4D-HDFI was the best method during the second trimester of pregnancy in identifying normal fetal pulmonary veins. 4D-HDFI images vividly depicted the figure, course, and drainage of pulmonary veins in both normal and TAPVC fetuses. HDFI and the advanced 4D-HDFI technique could facilitate identification of the anatomical features of pulmonary veins in both normal and TAPVC fetuses; 4D-HDFI therefore provides additional and more precise information than conventional echocardiography techniques. © 2017, Wiley Periodicals, Inc.

  5. Feasibility of perflutren microsphere contrast transthoracic echocardiography in the visualization of ventricular endocardium during venovenous extracorporeal membrane oxygenation in a validated ovine model.

    Science.gov (United States)

    Platts, David G; Diab, Sara; Dunster, Kimble R; Shekar, Kiran; Burstow, Darryl J; Sim, Beatrice; Tunbridge, Matthew; McDonald, Charles; Chemonges, Saul; Chan, Jonathan; Fraser, John F

    2015-03-01

    Transthoracic echocardiography (TTE) during extra corporeal membrane oxygenation (ECMO) is important but can be technically challenging. Contrast-specific TTE can improve imaging in suboptimal studies. These contrast microspheres are hydrodynamically labile structures. This study assessed the feasibility of contrast echocardiography (CE) during venovenous (VV) ECMO in a validated ovine model. Twenty-four sheep were commenced on VV ECMO. Parasternal long-axis (Plax) and short-axis (Psax) views were obtained pre- and postcontrast while on VV ECMO. Endocardial definition scores (EDS) per segment were graded: 1 = good, 2 = suboptimal 3 = not seen. Endocardial border definition score index (EBDSI) was calculated for each view. Endocardial length (EL) in the Plax view for the left ventricle (LV) and right ventricle (RV) was measured. Summation EDS data for the LV and RV for unenhanced TTE (UE) versus CE TTE imaging: EDS 1 = 289 versus 346, EDS 2 = 38 versus 10, EDS 3 = 33 versus 4, respectively. Wilcoxon matched-pairs rank-sign tests showed a significant ranking difference (improvement) pre- and postcontrast for the LV (P < 0.0001), RV (P < 0.0001) and combined ventricular data (P < 0.0001). EBDSI for CE TTE was significantly lower than UE TTE for the LV (1.05 ± 0.17 vs. 1.22 ± 0.38, P = 0.0004) and RV (1.06 ± 0.22 vs. 1.42 ± 0.47, P = 0.0.0006) respectively. Visualized EL was significantly longer in CE versus UE for both the LV (58.6 ± 11.0 mm vs. 47.4 ± 11.7 mm, P < 0.0001) and the RV (52.3 ± 8.6 mm vs. 36.0 ± 13.1 mm, P < 0.0001), respectively. Despite exposure to destructive hydrodynamic forces, CE is a feasible technique in an ovine ECMO model. CE results in significantly improved EDS and increased EL. © 2014, Wiley Periodicals, Inc.

  6. Low radiation dose non-contrast cardiac CT: is it of value in the evaluation of mechanical aortic valve

    International Nuclear Information System (INIS)

    Bazeed, Mohamed Fayez; Moselhy, Mohamed Saleh; Rezk, Ahmad Ibrahim; Al-Murayeh, Mushabab Ayedh

    2012-01-01

    Background: Prosthetic bileaflet mechanical valve function has been traditionally evaluated using echocardiography and fluoroscopy. Multidetector computed tomography (MDCT) is a novel technique for cardiac evaluation. Purpose: To evaluate bileaflet mechanical aortic valves using a low-milliampere (mA), non-contrast MDCT protocol with a limited scan range. Material and Methods: Forty patients with a bileaflet mechanical aortic valve were evaluated using a non-contrast, low-mA, ECG-gated 64 MDCT protocol with a limited scan range. MDCT findings of opening and closing valve angles were correlated to fluoroscopy and echocardiography. Also, the valve visibility was evaluated on MDCT and fluoroscopy according to a 3-point grading scale. Results: The visualization score with the MDCT was significantly superior to the fluoroscopy (3 vs. 2.7). A strong correlation was noted between the opening (r = 0.82) and closing (r = 0.96) valve angles with MDCT and fluoroscopy without a statistically significant difference (P = 0.31 and 0.16, respectively). The mean effective radiation dose of the suggested protocol was 4 ± 0.5 mSv. Five valves were evaluated using transesophageal echocardiography because the valves were difficult to evaluate with transthoracic echocardiography, and all of these valves were evaluated optimally with MDCT. A high-pressure gradient was noted in nine valves, and the MDCT showed that seven of these valves inadequately opened, and two valves opened well, which resulted in patient valve mismatch. Incomplete valve closure was noted in five valves, and the echocardiography showed significant transvalvular regurgitation in all five valves. Conclusion: MDCT can provide a precise measurement of valve function and can potentially evaluate high-pressure gradients and transvalvular regurgitation

  7. Low radiation dose non-contrast cardiac CT: is it of value in the evaluation of mechanical aortic valve

    Energy Technology Data Exchange (ETDEWEB)

    Bazeed, Mohamed Fayez (Dept. of Diagnostic Radiology, Faculty of Medicine, Mansoura Univ. (Egypt)), email: m_bazeed@yahoo.com; Moselhy, Mohamed Saleh (Cardiology Dept. Faculty of Medicine, Suez Canal Univ. (Egypt)); Rezk, Ahmad Ibrahim (Dept. of Cardiac Surgery, Faculty of Medicine, Aim Shams Univ. (Egypt)); Al-Murayeh, Mushabab Ayedh (Dept. of Cardiac Services, Armed Forces Hospitals Southern Region (Saudi Arabia))

    2012-05-15

    Background: Prosthetic bileaflet mechanical valve function has been traditionally evaluated using echocardiography and fluoroscopy. Multidetector computed tomography (MDCT) is a novel technique for cardiac evaluation. Purpose: To evaluate bileaflet mechanical aortic valves using a low-milliampere (mA), non-contrast MDCT protocol with a limited scan range. Material and Methods: Forty patients with a bileaflet mechanical aortic valve were evaluated using a non-contrast, low-mA, ECG-gated 64 MDCT protocol with a limited scan range. MDCT findings of opening and closing valve angles were correlated to fluoroscopy and echocardiography. Also, the valve visibility was evaluated on MDCT and fluoroscopy according to a 3-point grading scale. Results: The visualization score with the MDCT was significantly superior to the fluoroscopy (3 vs. 2.7). A strong correlation was noted between the opening (r = 0.82) and closing (r = 0.96) valve angles with MDCT and fluoroscopy without a statistically significant difference (P = 0.31 and 0.16, respectively). The mean effective radiation dose of the suggested protocol was 4 +- 0.5 mSv. Five valves were evaluated using transesophageal echocardiography because the valves were difficult to evaluate with transthoracic echocardiography, and all of these valves were evaluated optimally with MDCT. A high-pressure gradient was noted in nine valves, and the MDCT showed that seven of these valves inadequately opened, and two valves opened well, which resulted in patient valve mismatch. Incomplete valve closure was noted in five valves, and the echocardiography showed significant transvalvular regurgitation in all five valves. Conclusion: MDCT can provide a precise measurement of valve function and can potentially evaluate high-pressure gradients and transvalvular regurgitation

  8. Three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Buck, Thomas

    2011-01-01

    Presents tips and tricks for beginners and experts Provides educational material for 3D training courses Features comprehensively illustrated cases Includes an accompanying DVD with video clips of all sample cases Three-dimensional echocardiography is the most recent fundamental advancement in echocardiography. Since real-time 3D echocardiography became commercially available in 2002, it has rapidly been accepted in echo labs worldwide. This book covers all clinically relevant aspects of this fascinating new technology, including a comprehensive explanation of its basic principles, practical aspects of clinical application, and detailed descriptions of specific uses in the broad spectrum of clinically important heart disease. The book was written by a group of well-recognized international experts in the field, who have not only been involved in the scientific and clinical evolution of 3D echocardiography since its inception but are also intensively involved in expert training courses. As a result, the clear focus of this book is on the practical application of 3D echocardiography in daily clinical routine with tips and tricks for both beginners and experts, accompanied by more than 150 case examples comprehensively illustrated in more than 800 images and more than 500 videos provided on a DVD. In addition to an in-depth review of the most recent literature on real-time 3D echocardiography, this book represents an invaluable reference work for beginners and expert users of 3D echocardiography. - Tips and tricks for beginners and experts - Educational material for 3D training courses - Comprehensively illustrated cases - DVD with video clips of all sample cases.

  9. [Safety and efficacy of percutaneous patent ductus arteriosus closure solely under thoracic echocardiography guidance].

    Science.gov (United States)

    Pan, Xiangbin; Ouyang, Wenbin; Li, Shoujun; Guo, Gaili; Liu, Yao; Zhang, Dawei; Zhang, Fengwen; Pang, Kunjing; Fang, Nengxin; Hu, Shengshou

    2015-01-01

    To avoid the radiation injuries and use of contrast agent, we assessed the safety and efficacy of percutaneous patent ductus arteriosus closure solely under thoracic echocardiography guidance. From June 2013 to June 2014, thirty patients (mean age: (6.3 ± 2.5) years, mean body weight:(22.5 ± 7.3) kg) with pure patent ductus arteriosus were continuously included in this study. The mean diameter of patent ductus arteriosus was (3.8 ± 0.9) mm. Patients were all treated by percutaneous patent ductus arteriosus closure via right femoral artery solely under thoracic echocardiography guidance. The efficacy of the procedure was evaluated by thoracic echocardiography. Follow-up was performed at one month after procedure. All 30 cases were successfully treated with percutaneous patent ductus arteriosus closure solely under thracic echocardiography guidance. The procedural time was (32.8 ± 5.7) minutes. The mean diameter of Amplatzer ADO II was (4.9 ± 1.0) mm. Postoperative trivial residual shunt occurred in six patients immediately after the procedure. All patients survived without peripheral vascular injury or complications such as cardiac perforation. Hospitalization time was (3.4 ± 0.7) days. At one-month follow-up, no complications such as residual shunt or pericardial effusion were observed. Echocardiography guided percutaneous patent ductus arteriosus closure by femoral artery approach is safe and effective, and can avoid X-ray and the use of contrast agents.

  10. Utility of Angle Correction for Hemodynamic Measurements with Doppler Echocardiography.

    Science.gov (United States)

    Sigurdsson, Martin I; Eoh, Eun J; Chow, Vinca W; Waldron, Nathan H; Cleve, Jayne; Nicoara, Alina; Swaminathan, Madhav

    2018-04-06

    The routine application angle correction (AnC) in hemodynamic measurements with transesophageal echocardiography currently is not recommended but potentially could be beneficial. The authors hypothesized that AnC can be applied reliably and may change grading of aortic stenosis (AS). Retrospective analysis. Single institution, university hospital. During phase I, use of AnC was assessed in 60 consecutive patients with intraoperative transesophageal echocardiography. During phase II, 129 images from a retrospective cohort of 117 cases were used to quantify AS by mean pressure gradient. A panel of observers used custom-written software in Java to measure intra-individual and inter-individual correlation in AnC application, correlation with preoperative transthoracic echocardiography gradients, and regrading of AS after AnC. For phase I, the median AnC was 21 (16-35) degrees, and 17% of patients required no AnC. For phase II, the median AnC was 7 (0-15) degrees, and 37% of assessed images required no AnC. The mean inter-individual and intra-individual correlation for AnC was 0.50 (95% confidence interval [CI] 0.49-0.52) and 0.87 (95% CI 0.82-0.92), respectively. AnC did not improve agreement with the transthoracic echocardiography mean pressure gradient. The mean inter-rater and intra-rater agreement for grading AS severity was 0.82 (95% CI 0.81-0.83) and 0.95 (95% CI 0.91-0.95), respectively. A total of 241 (7%) AS gradings were reclassified after AnC was applied, mostly when the uncorrected mean gradient was within 5 mmHg of the severity classification cutoff. AnC can be performed with a modest inter-rater and intra-rater correlation and high degree of inter-rater and intra-rater agreement for AS severity grading. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. Reproducibility of right-to-left shunt quantification using transthoracic contrast echocardiography in hereditary haemorrhagic telangiectasia.

    Science.gov (United States)

    Vorselaars, V M M; Velthuis, S; Huitema, M P; Hosman, A E; Westermann, C J J; Snijder, R J; Mager, J J; Post, M C

    2018-04-01

    Transthoracic contrast echocardiography (TTCE) is recommended for screening of pulmonary arteriovenous malformations (PAVMs) in hereditary haemorrhagic telangiectasia. Shunt quantification is used to find treatable PAVMs. So far, there has been no study investigating the reproducibility of this diagnostic test. Therefore, this study aimed to describe inter-observer and inter-injection variability of TTCE. We conducted a prospective single centre study. We included all consecutive persons screened for presence of PAVMs in association with hereditary haemorrhagic telangiectasia in 2015. The videos of two contrast injections per patient were divided and reviewed by two cardiologists blinded for patient data. Pulmonary right-to-left shunts were graded using a three-grade scale. Inter-observer and inter-injection agreement was calculated with κ statistics for the presence and grade of pulmonary right-to-left shunts. We included 107 persons (accounting for 214 injections) (49.5% male, mean age 45.0 ± 16.6 years). A pulmonary right-to-left shunt was present in 136 (63.6%) and 131 (61.2%) injections for observer 1 and 2, respectively. Inter-injection agreement for the presence of pulmonary right-to-left shunts was 0.96 (95% confidence interval (CI) 0.9-1.0) and 0.98 (95% CI 0.94-1.00) for observer 1 and 2, respectively. Inter-injection agreement for pulmonary right-to-left shunt grade was 0.96 (95% CI 0.93-0.99) and 0.95 (95% CI 0.92-0.98) respectively. There was disagreement in right-to-left shunt grade between the contrast injections in 11 patients (10.3%). Inter-observer variability for presence and grade of the pulmonary right-to-left shunt was 0.95 (95% CI 0.91-0.99) and 0.97 (95% CI 0.95-0.99) respectively. TTCE has an excellent inter-injection and inter-observer agreement for both the presence and grade of pulmonary right-to-left shunts.

  12. Physiology knowledge plays a role when novices learn technical echocardiography skills

    DEFF Research Database (Denmark)

    Nielsen, Dorte Guldbrand; Gøtzsche, Ole; Eika, Berit

    2010-01-01

    Purpose: Little is known about factors of relevance for achieving technical skills of echocardiography (TTE); one of the essential skills defined by the European Society of Cardiology Core Curriculum. In an earlier study we have shown that there is a strong correlation between physiology knowledge...... and interpretation skills of intermediately trained echocardiographers. This study investigates the role of physiology knowledge in the development of echocardiographic technical expertise. Methods: Forty-five physicians (15 novices, 15 intermediates and 15 experts) were evaluated on technical skills. Participants...... of echocardiography relevant physiology knowledge. Results: A strong and significant correlation between expertise level and technical checklist scores was found (r = .76, p

  13. Stress echocardiography expert consensus statement

    NARCIS (Netherlands)

    R. Sicari (Rosa); P. Nihoyannopoulos (Petros); A. Evangelista (Arturo); J. Kasprzak (Jaroslav); P. Lancellotti (Patrizio); D. Poldermans (Don); J.U. Voigt; J.L. Zamorano (Jose)

    2008-01-01

    textabstractStress echocardiography is the combination of 2D echocardiography with a physical, pharmacological or electrical stress. The diagnostic end point for the detection of myocardial ischemia is the induction of a transient worsening in regional function during stress. Stress echocardiography

  14. 2010 Canadian Cardiovascular Society/Canadian Society of Echocardiography Guidelines for Training and Maintenance of Competency in Adult Echocardiography.

    Science.gov (United States)

    Burwash, Ian G; Basmadjian, Arsene; Bewick, David; Choy, Jonathan B; Cujec, Bibiana; Jassal, Davinder S; MacKenzie, Scott; Nair, Parvathy; Rudski, Lawrence G; Yu, Eric; Tam, James W

    2011-01-01

    Guidelines for the provision of echocardiography in Canada were jointly developed and published by the Canadian Cardiovascular Society and the Canadian Society of Echocardiography in 2005. Since their publication, recognition of the importance of echocardiography to patient care has increased, along with the use of focused, point-of-care echocardiography by physicians of diverse clinical backgrounds and variable training. New guidelines for physician training and maintenance of competence in adult echocardiography were required to ensure that physicians providing either focused, point-of-care echocardiography or comprehensive echocardiography are appropriately trained and proficient in their use of echocardiography. In addition, revision of the guidelines was required to address technological advances and the desire to standardize echocardiography training across the country to facilitate the national recognition of a physician's expertise in echocardiography. This paper summarizes the new Guidelines for Physician Training and Maintenance of Competency in Adult Echocardiography, which are considerably more comprehensive than earlier guidelines and address many important issues not previously covered. These guidelines provide a blueprint for physician training despite different clinical backgrounds and help standardize physician training and training programs across the country. Adherence to the guidelines will ensure that physicians providing echocardiography have acquired sufficient expertise required for their specific practice. The document will also provide a framework for other national societies to standardize their training programs in echocardiography and will provide a benchmark by which competency in adult echocardiography may be measured. Copyright © 2011 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  15. Evaluation of Subclinical Left Ventricular Systolic Dysfunction in Chronic Asymptomatic Alcoholics by Speckle Tracking Echocardiography

    Directory of Open Access Journals (Sweden)

    Murathan Kucuk

    2017-01-01

    Full Text Available By using two-dimensional speckle tracking echocardiography, we aimed to investigate the structural and functional changes on myocardium in chronic asymptomatic alcoholics without any cardiovascular disease. Forty-one consecutive asymptomatic male alcoholics who were admitted to the outpatient alcoholism unit and 30 age matched healthy male volunteers selected as the control group were enrolled in the study. The study group were investigated by using standard two-dimensional echocardiography and speckle tracking echocardiography. The left ventricular (LV global longitudinal strain and LV global circumferential strain were significantly lower in alcoholics when compared with control subjects. There was no difference in global radial strain between the two groups. To demonstrate the effect of total life time dose of ethanol (TLDE on echocardiographic abnormalities, we assessed the correlation analysis. There was a nonsignificant weak correlation between global LV circumferential strain and TLDE (r=0.27, p=0.083. Speckle tracking echocardiography derived left ventricular systolic function was impaired in chronic alcoholic patients when compared with healthy controls.

  16. Portopulmonary hypertension: Improved detection using CT and echocardiography in combination

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, Anand [Royal Brompton and Harefield NHS Foundation Trust, Department of Radiology, London (United Kingdom); Loveridge, Robert; Bernal, William; Willars, Christopher; Wendon, Julia A.; Auzinger, Georg [King' s College Hospital NHS Foundation Trust, The Institute of Liver Studies, King' s Health Partners, King' s College London, London (United Kingdom); Bosanac, Diana; Stefanidis, Konstantinos; Desai, Sujal R. [King' s College Hospital NHS Foundation Trust, Department of Radiology, King' s Health Partners, King' s College London, London (United Kingdom)

    2014-10-15

    To establish the relationship between CT signs of pulmonary hypertension and mean pulmonary artery pressure (mPAP) in patients with liver disease, and to determine the additive value of CT in the detection of portopulmonary hypertension in combination with transthoracic echocardiography. Forty-nine patients referred for liver transplantation were retrospectively reviewed. Measured CT signs included the main pulmonary artery/ascending aorta diameter ratio (PA/AA{sub meas}) and the mean left and right main PA diameter (RLPA{sub meas}). Enlargement of the pulmonary artery compared to the ascending aorta was also assessed visually (PA/AA{sub vis}). CT measurements were correlated with right-sided heart catheter-derived mPAP. The ability of PA/AA{sub vis} combined with echocardiogram-derived right ventricular systolic pressure (RVSP) to detect portopulmonary hypertension was tested with ROC analysis. There were moderate correlations between mPAP and both PA/AA{sub meas} and RLPA{sub meas} (r{sub s} = 0.41 and r{sub s} = 0.42, respectively; p < 0.005). Compared to transthoracic echocardiography alone (AUC = 0.59, p = 0.23), a diagnostic algorithm incorporating PA/AA{sub vis} and transthoracic echocardiography-derived RVSP improved the detection of portopulmonary hypertension (AUC = 0.8, p < 0.0001). CT contributes to the non-invasive detection of portopulmonary hypertension when used in a diagnostic algorithm with transthoracic echocardiography. CT may have a role in the pre-liver transplantation triage of patients with portopulmonary hypertension for right-sided heart catheterisation. (orig.)

  17. Effect of gender on the prognostic value of dobutamine stress myocardial contrast echocardiography

    Directory of Open Access Journals (Sweden)

    Constantina Aggeli

    2017-11-01

    Full Text Available Background: Dobutamine stress contrast echo (DSCE has a well-established prognostic value in the context of coronary artery disease (CAD. However, data regarding its prognostic capability separately in men and women are scarce. The aim of the current study was to assess gender-related differences in the prognostic performance of DSCE. Methods: DSCE was performed in 2645 consecutive patients, who were classified into two groups depending on gender. Follow-up lasted 57.1±10.1 months. End points included all-cause mortality, cardiac death, late revascularization, and hospitalizations. Survival analysis was performed comparing men and women. Results: Of the 2645 patients (59.3±8.7 years, 69.1% were men. DSCE was positive in 23.4% of male patients, while in females, the respective percentage was 14.3%. There was statistically significant difference between the two groups with regard to end point occurrence (11.6% vs. 6.1%, p<0.05. Multivariate analysis revealed that the DSCE response was the strongest predictor of adverse outcomes (Exp(B=51.9, p<0.05 in both groups. The predictive model including DSCE results along with clinical data performed well without significant differences between males and females (C-index 0.93 vs. 0.87 respectively, p=NS. Conclusion: DSCE has a strong prognostic value for patients with known or suspected CAD, regardless of patient gender. This makes DSCE an attractive screening option for women in whom CAD assessment can be challenging. Keywords: stress echocardiography, women, gender, prognosis, coronary artery disease

  18. Head-to-head comparison of peak supine bicycle exercise echocardiography and treadmill exercise echocardiography at peak and at post-exercise for the detection of coronary artery disease.

    Science.gov (United States)

    Peteiro, Jesús; Bouzas-Mosquera, Alberto; Estevez, Rodrigo; Pazos, Pablo; Piñeiro, Miriam; Castro-Beiras, Alfonso

    2012-03-01

    echocardiography diagnosed multivessel disease in 27 of the 40 patients with stenoses in more than one coronary artery, in contrast to 17 patients with peak SBE imaging and 12 with post-TME imaging (P peak TME imaging and the other modalities). Image quality was similar with the three techniques. The duration of the test was longer with SBE echocardiography (9.5 ± 3.8 vs 7.6 ± 2.5 min, P peak TME, which makes peak TME a more valuable exercise echocardiographic modality to increase sensitivity. However, peak SBE should be preferred to TME if the latter is performed with postexercise imaging acquisition. Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

  19. Echocardiography Practice: Insights into Appropriate Clinical Use, Technical Competence and Quality Improvement Program

    Science.gov (United States)

    Kossaify, Antoine; Grollier, Gilles

    2014-01-01

    Echocardiography accounts for nearly half of all cardiac imaging techniques. It is a widely available and adaptable tool, as well as being a cost-effective and mainly a non-invasive test. In addition, echocardiography provides extensive clinical data, which is related to the presence or advent of different modalities (tissue Doppler imaging, speckle tracking imaging, three-dimensional mode, contrast echo, etc.), different approaches (transesophageal, intravascular, etc.), and different applications (ie, heart failure/resynchronization studies, ischemia/stress echo, etc.). In view of this, it is essential to conform to criteria of appropriate use and to keep standards of competence. In this study, we sought to review and discuss clinical practice of echocardiography in light of the criteria of appropriate clinical use, also we present an insight into echocardiographic technical competence and quality improvement project. PMID:24516342

  20. Information processing correlates of a size-contrast illusion

    Directory of Open Access Journals (Sweden)

    Jason M Gold

    2014-02-01

    Full Text Available Perception is often influenced by context. A well-known class of perceptual context effects is perceptual contrast illusions, in which proximate stimulus regions interact to alter the perception of various stimulus attributes, such as perceived brightness, color and size. Although the phenomenal reality of contrast effects is well documented, in many cases the connection between these illusions and how information is processed by perceptual systems is not well understood. Here, we use noise as a tool to explore the information processing correlates of one such contrast effect: the Ebbinghaus-Titchener size-contrast illusion. In this illusion, the perceived size of a central dot is significantly altered by the sizes of a set of surrounding dots, such that the presence of larger surrounding dots tends to reduce the perceived size of the central dot (and vise-versa. In our experiments, we first replicated previous results that have demonstrated the subjective reality of the Ebbinghaus-Titchener illusion. We then used visual noise in a detection task to probe the manner in which observers processed information when experiencing the illusion. By correlating the noise with observers’ classification decisions, we found that the sizes of the surrounding contextual elements had a direct influence on the relative weight observers assigned to regions within and surrounding the central element. Specifically, observers assigned relatively more weight to the surrounding region and less weight to the central region in the presence of smaller surrounding contextual elements. These results offer new insights into the connection between the subjective experience of size-contrast illusions and their associated information processing correlates.

  1. The practice of echocardiography

    International Nuclear Information System (INIS)

    Kraus, R.

    1985-01-01

    This volume is an anthology by noted authorities on all clinically useful aspects of echocardiography. Its articles cover such subjects as: historical perspectives, physics, instrumentation and techniques, M mode and 2D echocardiography

  2. Three-dimensional echocardiography of normal and pathologic mitral valve: a comparison with two-dimensional transesophageal echocardiography

    NARCIS (Netherlands)

    Salustri, A.; Becker, A. E.; van Herwerden, L.; Vletter, W. B.; ten Cate, F. J.; Roelandt, J. R.

    1996-01-01

    This study was done to ascertain whether three-dimensional echocardiography can facilitate the diagnosis of mitral valve abnormalities. The value of the additional information provided by three-dimensional echocardiography compared with two-dimensional multiplane transesophageal echocardiography for

  3. American Society of Echocardiography

    Science.gov (United States)

    American Society of Echocardiography Join Ase Renew Member Portal Log In Membership Member Portal Log In Join ASE Renew Benefits Rates FASE – Fellow of the American Society of Echocardiography Member Referral Program FAQs Initiatives Advocacy Awards, Grants, ...

  4. Guidelines for the Use of Echocardiography in the Evaluation of a Cardiac Source of Embolism.

    Science.gov (United States)

    Saric, Muhamed; Armour, Alicia C; Arnaout, M Samir; Chaudhry, Farooq A; Grimm, Richard A; Kronzon, Itzhak; Landeck, Bruce F; Maganti, Kameswari; Michelena, Hector I; Tolstrup, Kirsten

    2016-01-01

    Embolism from the heart or the thoracic aorta often leads to clinically significant morbidity and mortality due to transient ischemic attack, stroke or occlusion of peripheral arteries. Transthoracic and transesophageal echocardiography are the key diagnostic modalities for evaluation, diagnosis, and management of stroke, systemic and pulmonary embolism. This document provides comprehensive American Society of Echocardiography guidelines on the use of echocardiography for evaluation of cardiac sources of embolism. It describes general mechanisms of stroke and systemic embolism; the specific role of cardiac and aortic sources in stroke, and systemic and pulmonary embolism; the role of echocardiography in evaluation, diagnosis, and management of cardiac and aortic sources of emboli including the incremental value of contrast and 3D echocardiography; and a brief description of alternative imaging techniques and their role in the evaluation of cardiac sources of emboli. Specific guidelines are provided for each category of embolic sources including the left atrium and left atrial appendage, left ventricle, heart valves, cardiac tumors, and thoracic aorta. In addition, there are recommendation regarding pulmonary embolism, and embolism related to cardiovascular surgery and percutaneous procedures. The guidelines also include a dedicated section on cardiac sources of embolism in pediatric populations. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  5. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  6. Echocardiography-guided or "sided" pericardiocentesis.

    Science.gov (United States)

    Degirmencioglu, Aleks; Karakus, Gultekin; Güvenc, Tolga Sinan; Pinhan, Osman; Sipahi, Ilke; Akyol, Ahmet

    2013-10-01

    Echocardiography-guided pericardiocentesis is the first choice method for relieving cardiac tamponade, but the exact role of the echocardiography at the moment of the puncture is still controversial. In this report, detailed echocardiographic evaluation was performed in 21 consecutive patients with cardiac tamponade just before the pericardiocentesis. Appropriate needle position was determined according to the probe position using imaginary x, y, and z axes. Pericardiocentesis was performed successfully using this technique without simultaneous echocardiography and no complications were observed. We concluded that bedside echocardiography with detailed evaluation of the puncture site and angle is enough for pericardiocentesis instead of real time guiding. © 2013, Wiley Periodicals, Inc.

  7. Left ventricular mass and hypertrophy by echocardiography and cardiac magnetic resonance: the multi-ethnic study of atherosclerosis.

    Science.gov (United States)

    Armstrong, Anderson C; Gjesdal, Ola; Almeida, André; Nacif, Marcelo; Wu, Colin; Bluemke, David A; Brumback, Lyndia; Lima, João A C

    2014-01-01

    Left ventricular mass (LVM) and hypertrophy (LVH) are important parameters, but their use is surrounded by controversies. We compare LVM by echocardiography and cardiac magnetic resonance (CMR), investigating reproducibility aspects and the effect of echocardiography image quality. We also compare indexing methods within and between imaging modalities for classification of LVH and cardiovascular risk. Multi-Ethnic Study of Atherosclerosis enrolled 880 participants in Baltimore city, 146 had echocardiograms and CMR on the same day. LVM was then assessed using standard techniques. Echocardiography image quality was rated (good/limited) according to the parasternal view. LVH was defined after indexing LVM to body surface area, height(1.7) , height(2.7) , or by the predicted LVM from a reference group. Participants were classified for cardiovascular risk according to Framingham score. Pearson's correlation, Bland-Altman plots, percent agreement, and kappa coefficient assessed agreement within and between modalities. Left ventricular mass by echocardiography (140 ± 40 g) and by CMR were correlated (r = 0.8, P echocardiography image quality. The reproducibility profile had strong correlations and agreement for both modalities. Image quality groups had similar characteristics; those with good images compared to CMR slightly superiorly. The prevalence of LVH tended to be higher with higher cardiovascular risk. The agreement for LVH between imaging modalities ranged from 77% to 98% and the kappa coefficient from 0.10 to 0.76. Echocardiography has a reliable performance for LVM assessment and classification of LVH, with limited influence of image quality. Echocardiography and CMR differ in the assessment of LVH, and additional differences rise from the indexing methods. © 2013. This article is a U.S. Government work and is in the public domain in the USA.

  8. Multidetector CT evaluation of total anomalous pulmonary venous connections: comparison with echocardiography

    International Nuclear Information System (INIS)

    Oh, Ki Ho; Choo, Ki Seok; Lim, Soo Jin; Lee, Hyoung Doo; Park, Ji Ae; Jo, Min Jung; Sung, Si Chan; Chang, Yun Hee; Jeong, Dong Wook; Kim, Siho

    2009-01-01

    Although echocardiography is the first-line imaging modality in the diagnosis of total anomalous pulmonary venous connection (TAPVC), multidetector CT (MDCT) could have advantages in the diagnosis of TAPVC in certain cases. To compare MDCT with echocardiography in the evaluation of TAPVC. Enrolled in the study were 23 patients with surgically proven TAPVC. The echocardiography and MDCT findings were independently interpreted by a paediatric cardiologist and cardiac radiologist in terms of: (1) the drainage site of the common pulmonary vein, (2) stenosis of the vertical vein, and (3) the course of the atypical vessel into the systemic vein in the case of vertical vein stenosis. The findings from both modalities were correlated with the results obtained at surgery (n=22) or autopsy (n=1). In all patients, MDCT correctly depicted the drainage site of the common pulmonary vein, stenosis of the vertical vein and the course of the atypical vessel into the systemic vein (sensitivity 100%, specificity 100%). The specificity of echocardiography was 100% for the three defined findings. The sensitivity of echocardiography, however, was 87%, 71% and 0%, respectively. MDCT can facilitate the diagnosis of TAPVC in certain cases. (orig.)

  9. Portopulmonary hypertension: Improved detection using CT and echocardiography in combination

    International Nuclear Information System (INIS)

    Devaraj, Anand; Loveridge, Robert; Bernal, William; Willars, Christopher; Wendon, Julia A.; Auzinger, Georg; Bosanac, Diana; Stefanidis, Konstantinos; Desai, Sujal R.

    2014-01-01

    To establish the relationship between CT signs of pulmonary hypertension and mean pulmonary artery pressure (mPAP) in patients with liver disease, and to determine the additive value of CT in the detection of portopulmonary hypertension in combination with transthoracic echocardiography. Forty-nine patients referred for liver transplantation were retrospectively reviewed. Measured CT signs included the main pulmonary artery/ascending aorta diameter ratio (PA/AA meas ) and the mean left and right main PA diameter (RLPA meas ). Enlargement of the pulmonary artery compared to the ascending aorta was also assessed visually (PA/AA vis ). CT measurements were correlated with right-sided heart catheter-derived mPAP. The ability of PA/AA vis combined with echocardiogram-derived right ventricular systolic pressure (RVSP) to detect portopulmonary hypertension was tested with ROC analysis. There were moderate correlations between mPAP and both PA/AA meas and RLPA meas (r s = 0.41 and r s = 0.42, respectively; p vis and transthoracic echocardiography-derived RVSP improved the detection of portopulmonary hypertension (AUC = 0.8, p < 0.0001). CT contributes to the non-invasive detection of portopulmonary hypertension when used in a diagnostic algorithm with transthoracic echocardiography. CT may have a role in the pre-liver transplantation triage of patients with portopulmonary hypertension for right-sided heart catheterisation. (orig.)

  10. Assessment of left ventricular myocardial function using 16-slice multidetector-row computed tomography: comparison with magnetic resonance imaging and echocardiography

    International Nuclear Information System (INIS)

    Heuschmid, Martin; Rothfuss, Julia K.; Fenchel, Michael; Stauder, Norbert; Kuettner, Axel; Miller, Stephan; Claussen, Claus D.; Kopp, Andreas F.; Schroeder, Stephen; Burgstahler, Christof; Franow, Andreas; Kuzo, Ronald S.

    2006-01-01

    To assess functional parameters using multidetector-row computed tomography (MDCT) and echocardiography and to compare the results with magnetic resonance imaging (MRI). End-diastolic-volume (EDV), end-systolic-volume (ESV), stroke-volume (SV), ejection-fraction (EF), and myocardial mass (MM) were calculated based on CT data sets from 52 patients. Echocardiography was performed in 24 of the 52 patients. The results from MDCT and echocardiography were compared with MRI. A strong correlation between MDCT and MRI (r=0.66-0.90) was found for all parameters. Echocardiography revealed a low or moderate correlation (0.05-0.59). Compared to MRI the average differences with MDCT were for EDV 15.1 ml, ESV 10.6 ml, SV 4.5 ml, EF 1.8%, and MM 8.2 g, for EDV determined by echocardiography 36.2 ml, ESV 6.8 ml, and EF 13.9%. Bland-Altman analysis revealed acceptable limits of agreement between MRI and MDCT. MDCT enables reliable quantification of left ventricular function. Echocardiography was found to have only a moderate agreement of functional parameters with MRI. (orig.)

  11. Fetal echocardiography

    International Nuclear Information System (INIS)

    Chaubal, Nitin G.; Chaubal, Jyoti

    2009-01-01

    USG performed with a high-end machine, using a good cine-loop facility is extremely helpful in the diagnosis of fetal cardiac anomalies. In fetal echocardiography, the four-chamber view and the outflow-tract view are used to diagnose cardiac anomalies. The most important objective during a targeted anomaly scan is to identify those cases that need a dedicated fetal echocardiogram. Associated truncal and chromosomal anomalies need to be identified. This review shows how fetal echocardiography, apart from identifying structural defects in the fetal heart, can be used to look at rhythm abnormalities and other functional aspects of the fetal heart

  12. Comparison of Cine-MRI and Transthoracic Echocardiography for the Assessment of Aortic Root Diameters in Patients with Suspected Marfan Syndrome.

    Science.gov (United States)

    Bannas, P; Rybczynski, M; Sheikhzadeh, S; von Kodolitsch, Y; Derlin, T; Yamamura, J; Lund, G; Adam, G; Groth, M

    2015-11-01

    Patients with Marfan syndrome require repeated imaging for monitoring of aortic root aneurysms. Therefore, we evaluated the agreement and reproducibility of cine-MRI and echocardiography measurements of the sinuses of Valsalva in patients with suspected Marfan syndrome. 51 consecutive patients with suspected Marfan syndrome were prospectively examined using cine-MRI and echocardiography. Two readers independently measured aortic root diameters at the level of the sinuses of Valsalva in both cine-MRI and echocardiography. Statistics included intraclass correlation coefficient, Pearson correlation coefficient, Bland-Altman analysis, and two-sided t-test. In 38 of the 51 individuals (74.5 %), the diagnosis of Marfan syndrome was established according to the criteria of the Ghent-2 nosology. Cine-MRI measurements of the sinuses of Valsalva revealed a strong correlation with echocardiography (r = 0.929), but a statistically significant bias of -1.0  mm (p Marfan syndrome. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Effect of static scatterers in laser speckle contrast imaging: an experimental study on correlation and contrast

    Science.gov (United States)

    Vaz, Pedro G.; Humeau-Heurtier, Anne; Figueiras, Edite; Correia, Carlos; Cardoso, João

    2018-01-01

    Laser speckle contrast imaging (LSCI) is a non-invasive microvascular blood flow assessment technique with good temporal and spatial resolution. Most LSCI systems, including commercial devices, can perform only qualitative blood flow evaluation, which is a major limitation of this technique. There are several factors that prevent the utilization of LSCI as a quantitative technique. Among these factors, we can highlight the effect of static scatterers. The goal of this work was to study the influence of differences in static and dynamic scatterer concentration on laser speckle correlation and contrast. In order to achieve this, a laser speckle prototype was developed and tested using an optical phantom with various concentrations of static and dynamic scatterers. It was found that the laser speckle correlation could be used to estimate the relative concentration of static/dynamic scatterers within a sample. Moreover, the speckle correlation proved to be independent of the dynamic scatterer velocity, which is a fundamental characteristic to be used in contrast correction.

  14. Contrast-enhanced magnetic resonance angiography of persistent fifth aortic arch in children

    International Nuclear Information System (INIS)

    Zhong, Yumin; Zhu, Ming; Sun, Aimin; Li, Yuhua; Jaffe, Richard B.; Gao, Wei

    2007-01-01

    Cine angiography and echocardiography have been utilized to diagnose congenital aortic arch anomalies. However, the visualization of great vessels by echocardiography is limited, while cine angiography requires cardiac catheterization with ionizing radiation. Contrast-enhanced magnetic resonance angiography (MRA) is a noninvasive modality suitable for visualization of congenital aortic arch anomalies. To evaluate the utility of contrast-enhanced MRA in the diagnosis of persistent fifth aortic arch, a rare congenital aortic arch anomaly, and to compare the diagnostic accuracy of MRA with that of echocardiography and cine angiography. In four pediatric patients, contrast-enhanced MRA studies were performed for diagnosing persistent fifth aortic arch. The findings of MRA were compared with echocardiographic findings and confirmed by cine angiography and operation. Transthoracic surface echocardiography noted an aberrant vessel arising from the ascending aorta in two of four patients; the etiology of this vessel was uncertain. In the other two patients a diagnosis of coarctation was made. Of the four patients, only one was diagnosed with interruption of the aortic arch. Contrast-enhanced MRA clarified uncertain echocardiographic findings, enabling the correct diagnosis of persistent fifth aortic arch with fourth aortic arch interruption in all four patients. Contrast-enhanced MRA is a safe, accurate, and fast imaging technique for the evaluation of persistent fifth aortic arch and may obviate the need for conventional cine angiography. Cardiac catheterization may be reserved for some types of complicated congenital heart disease and for obtaining hemodynamic information. (orig.)

  15. Significance of blood pool scintigraphy and echocardiography in the investigation of left heart ventricle

    International Nuclear Information System (INIS)

    Otto, L.; Krosse, B.; Neumann, G.; Rother, T.; Loebe, M.; Otto, J.; Koegler, A.; Wuensche, A.; Schneider, G.

    1990-01-01

    Left ventricular ejection (LVEF) was assessed by both radionuclide ventriculography and echocardiography. The correlation coefficient of 0.74 revealed a just good agreement. It was better in the range of normal than of pathological values. The analysis of regional wall motion performed by echocardiography was not as reliable as by radionuclide ventriculography. The main advantage of echocardiography is its good spatial resolution. Its domain is the diagnosis of pathomorphological changes including valvular disorders. Advantages of radionuclide ventriculography are good temporal resolution, registration of the third dimension practicability during exercise and as bedside method (nuclear stethoscope). Functional disturbances of both ventricles are its field of application. (author)

  16. Simplified single plane echocardiography is comparable to conventional biplane two-dimensional echocardiography in the evaluation of left atrial volume: a study validated by three-dimensional echocardiography in 143 individuals.

    Science.gov (United States)

    Vieira-Filho, Normando G; Mancuso, Frederico J N; Oliveira, Wercules A A; Gil, Manuel A; Fischer, Cláudio H; Moises, Valdir A; Campos, Orlando

    2014-03-01

    The left atrial volume index (LAVI) is a biomarker of diastolic dysfunction and a predictor of cardiovascular events. Three-dimensional echocardiography (3DE) is highly accurate for LAVI measurements but is not widely available. Furthermore, biplane two-dimensional echocardiography (B2DE) may occasionally not be feasible due to a suboptimal two-chamber apical view. Simplified single plane two-dimensional echocardiography (S2DE) could overcome these limitations. We aimed to compare the reliability of S2DE with other validated echocardiographic methods in the measurement of the LAVI. We examined 143 individuals (54 ± 13 years old; 112 with heart disease and 31 healthy volunteers; all with sinus rhythm, with a wide range of LAVI). The results for all the individuals were compared with B2DE-derived LAVIs and validated using 3DE. The LAVIs, as determined using S2DE (32.7 ± 13.1 mL/m(2)), B2DE (31.9 ± 12.7 mL/m(2)), and 3DE (33.1 ± 13.4 mL/m(2)), were not significantly different from each other (P = 0.85). The S2DE-derived LAVIs correlated significantly with those obtained using both B2DE (r = 0.98; P < 0.001) and 3DE (r = 0.93; P < 0.001). The mean difference between the S2DE and B2DE measurements was <1.0 mL/m(2). Using the American Society of Echocardiography criteria for grading LAVI enlargement (normal, mild, moderate, severe), we observed an excellent agreement between the S2DE- and B2DE-derived classifications (κ = 0.89; P < 0.001). S2DE is a simple, rapid, and reliable method for LAVI measurement that may expand the use of this important biomarker in routine echocardiographic practice. © 2013, Wiley Periodicals, Inc.

  17. Myocardial perfusion SPECT for assessment of left ventricular function and volume- comparison with echocardiography

    International Nuclear Information System (INIS)

    Cheng Xu; Huang Gang

    2004-01-01

    Objective: The purpose of this study was to evaluate left ventricular volume and function by gated SPECT and comparison of the results with echocardiography. Methods: 65 Consecutive patients (49 male, 16 female; mean age 61+11 years) who underwent both gated 99m Tc-MIBI myocardial perfusion SPECT and echocardiography within a 15 days period were included in the study. Exclusion criteria were any change in clinical status between acquisition of the gated SPECT and echocardiography studies, acute myocardial infarction occurring less than 7 days before study, and surgical procedures occurring within 30 days of the study. The clinical diagnosis of each patient was not considered, as this was not relevant to the purpose of the study. The diagnoses were as follows: coronary artery disease (n=46), hypertensive heart disease (n=8), old myocardial infarction (n=5), myocarditis (n=2), and routine medical examination(n=4). A dose of 740 MBq of 99 Tc m -sestamibi was administered in resting condition. Gated SPECT images were obtained with ADAC Vertex MCD-AC SPECT system. The raw projection images were reconstructed with filtered back-projection (ramp filter), without attenuation correction. The data, including left ventricular ejection fraction (LVEF), end-diastolic volume (EDV), end-systolic volume (ESV) were obtained using AUTOQUANT software (ADAC corporation). The echocardiography study used its standard techniques. Two nuclear medicine physicians processed the raw images respectively to evaluate internal reproducibility of gated SPECT. In order to compare the results of gated SPECT with echocardiography on different left ventricular volumes, all patients were divided into two groups (EDV 90 ml, n=34) based by EDV measurements in echocardiography. Results: The correlation coefficient of LVEF, EDV, ESV between SPECT and echocardiography were 0.77, 0.86 and 0.90 respectively. P 0.07). The reproducibility of gated SPECT was excellent. There were no significant differences in

  18. Value of MR phase-contrast flow measurements for functional assessment of pulmonary arterial hypertension

    International Nuclear Information System (INIS)

    Ley, Sebastian; Mereles, Derliz; Gruenig, Ekkehard; Puderbach, Michael; Schoeck, Helena; Eichinger, Monika; Ley-Zaporozhan, Julia; Fink, Christian; Kauczor, Hans-Ulrich

    2007-01-01

    Goals of our study were to compare the pulmonary hemodynamics between healthy volunteers and patients with pulmonary arterial hypertension (PAH) and correlate MR flow measurements with echocardiography. Twenty-five patients with PAH and 25 volunteers were examined at 1.5 T. Phase-contrast flow measurements were performed in the ascending aorta and pulmonary trunk, resulting in the following parameters: peak velocity (cm/s), average blood flow (l/min), time to peak velocity (ms), velocity rise gradient and pulmonary distensibility (cm 2 ). The bronchosystemic shunt was calculated. In PAH patients transthoracic echocardiography and right-heart catheterization (RHC) served as the gold standard. In comparison to volunteers, the PAH patients showed significantly reduced pulmonary velocities (P = 0.002), blood flow (P = 0.002) and pulmonary distensibility (P = 0.008). In patients, the time to peak velocity was shorter (P<0.001), and the velocity rise gradient was steeper (P = 0.002) than in volunteers. While in volunteers the peak velocity in the aorta was reached earlier, it was the reverse in patients. Patients showed a significant bronchosystemic shunt (P = 0.01). No meaningful correlation was found between MRI measurements and echocardiography or RHC. MRI is a feasible technique for the differentiation between PAH and volunteers. Further studies have to be conducted for the absolute calculation of pressure estimates. (orig.)

  19. Guideline from Japanese Society of Echocardiography: 2018 focused update incorporated into Guidance for the Management and Maintenance of Echocardiography Equipment.

    Science.gov (United States)

    Daimon, Masao; Akaishi, Makoto; Asanuma, Toshihiko; Hashimoto, Shuji; Izumi, Chisato; Iwanaga, Shiro; Kawai, Hiroya; Toide, Hiroyuki; Hayashida, Akihiro; Yamada, Hirotsugu; Murata, Mitsushige; Hirano, Yutaka; Suzuki, Kengo; Nakatani, Satoshi

    2018-03-01

    Echocardiography plays a pivotal role as an imaging modality in the modern cardiology practice. Information derived from echocardiography is definitely helpful for a patient care. The Japanese Society of Echocardiography has promoted echocardiography for a routine clinical and research use. One of the missions of the Society is to provide information that is useful for high-quality examinations. To ensure it, we believe equipment in good conditions and a comfortable environment are important for both a patient and an examiner. Thus, the Committee for Guideline Writing, the Japanese Society of Echocardiography published brief guidance for the routine use of echocardiography equipment in 2015. Recently, the importance of international standardization has been emphasized in the medical laboratories. Accordingly, the committee has revised and updated our guidance for the routine use of echocardiography equipment.

  20. Hemodynamic stress echocardiography in patients supported with a continuous-flow left ventricular assist device

    DEFF Research Database (Denmark)

    Andersen, Mads Jønsson; Gustafsson, Finn; Madsen, Per Lav

    2010-01-01

    exercise. Exercise induced an increase in cardiac output, systolic pulmonary artery pressure, and diastolic pulmonary artery pressure. Although no changes in left ventricular dimensions or fractional shortening were seen on echocardiography, systolic mitral annular motion (S') increased significantly (in...... parallel with cardiac output) and diastolic E/e' ratio decreased (correlating inversely with diastolic pulmonary artery pressure). These findings emphasize the potential role of exercise echocardiography in studying exercise hemodynamics in LVAD patients....

  1. Comparison of cine-MRI and transthoracic echocardiography for the assessment of aortic root diameters in patients with suspected Marfan syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Bannas, P.; Derlin, T.; Yamamura, J.; Lund, G.; Adam, G. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of Diagnostic and Interventional Radiology; Rybczynski, M.; Sheikhzadeh, S.; Kodolitsch, Y. von [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Dept. of General and Interventional Cardiology; Groth, M. [University Medical Center Hamburg-Eppendorf, Hamburg (Germany). Section for Pediatric Radiology

    2015-11-15

    Patients with Marfan syndrome require repeated imaging for monitoring of aortic root aneurysms. Therefore, we evaluated the agreement and reproducibility of cine-MRI and echocardiography measurements of the sinuses of Valsalva in patients with suspected Marfan syndrome. 51 consecutive patients with suspected Marfan syndrome were prospectively examined using cine-MRI and echocardiography. Two readers independently measured aortic root diameters at the level of the sinuses of Valsalva in both cine-MRI and echocardiography. Statistics included intraclass correlation coefficient, Pearson correlation coefficient, Bland-Altman analysis, and two-sided t-test. In 38 of the 51 individuals (74.5 %), the diagnosis of Marfan syndrome was established according to the criteria of the Ghent-2 nosology. Cine-MRI measurements of the sinuses of Valsalva revealed a strong correlation with echocardiography (r=0.929), but a statistically significant bias of -1.0 mm (p<0.001). The mean absolute diameter for sinuses of Valsalva obtained by cine-MRI was 32.3 ± 5.8 mm as compared to 33.4 ± 5.4 mm obtained by echocardiography. Interobserver agreement of measurements of the sinuses of Valsalva was higher for cine-MRI than for echocardiography (p=0.029). Despite small, but statistically significant differences in terms of agreement and reproducibility, cine-MRI and echocardiographic measurements of aortic root diameters provide comparable results without a significant clinical difference. Therefore both techniques may be used for monitoring of the aortic root in patients with Marfan syndrome.

  2. Comparison of cine-MRI and transthoracic echocardiography for the assessment of aortic root diameters in patients with suspected Marfan syndrome

    International Nuclear Information System (INIS)

    Bannas, P.; Derlin, T.; Yamamura, J.; Lund, G.; Adam, G.; Rybczynski, M.; Sheikhzadeh, S.; Kodolitsch, Y. von; Groth, M.

    2015-01-01

    Patients with Marfan syndrome require repeated imaging for monitoring of aortic root aneurysms. Therefore, we evaluated the agreement and reproducibility of cine-MRI and echocardiography measurements of the sinuses of Valsalva in patients with suspected Marfan syndrome. 51 consecutive patients with suspected Marfan syndrome were prospectively examined using cine-MRI and echocardiography. Two readers independently measured aortic root diameters at the level of the sinuses of Valsalva in both cine-MRI and echocardiography. Statistics included intraclass correlation coefficient, Pearson correlation coefficient, Bland-Altman analysis, and two-sided t-test. In 38 of the 51 individuals (74.5 %), the diagnosis of Marfan syndrome was established according to the criteria of the Ghent-2 nosology. Cine-MRI measurements of the sinuses of Valsalva revealed a strong correlation with echocardiography (r=0.929), but a statistically significant bias of -1.0 mm (p<0.001). The mean absolute diameter for sinuses of Valsalva obtained by cine-MRI was 32.3 ± 5.8 mm as compared to 33.4 ± 5.4 mm obtained by echocardiography. Interobserver agreement of measurements of the sinuses of Valsalva was higher for cine-MRI than for echocardiography (p=0.029). Despite small, but statistically significant differences in terms of agreement and reproducibility, cine-MRI and echocardiographic measurements of aortic root diameters provide comparable results without a significant clinical difference. Therefore both techniques may be used for monitoring of the aortic root in patients with Marfan syndrome.

  3. Pericardial Effusion and Pericardiocentesis: Role of Echocardiography

    Science.gov (United States)

    2012-01-01

    Pericardial effusion can develop from any pericardial disease, including pericarditis and several systemic disorders, such as malignancies, pulmonary tuberculosis, chronic renal failure, thyroid diseases, and autoimmune diseases. The causes of large pericardial effusion requiring invasive pericardiocentesis may vary according to the time, country, and hospital. Transthoracic echocardiography is the most important tool for diagnosis, grading, the pericardiocentesis procedure, and follow up of pericardial effusion. Cardiac tamponade is a kind of cardiogenic shock and medical emergency. Clinicians should understand the tamponade physiology, especially because it can develop without large pericardial effusion. In addition, clinicians should correlate the echocardiographic findings of tamponade, such as right ventricular collapse, right atrial collapse, and respiratory variation of mitral and tricuspid flow, with clinical signs of clinical tamponade, such as hypotension or pulsus paradoxus. Percutaneous pericardiocentesis has been the most useful procedure in many cases of large pericardial effusion, cardiac tamponade, or pericardial effusion of unknown etiology. The procedure should be performed with the guidance of echocardiography. PMID:23236323

  4. Transesophageal echocardiography in NeoChord procedure

    Directory of Open Access Journals (Sweden)

    Pittarello Demetrio

    2015-01-01

    Full Text Available Background: Transapical off-pump mitral valve intervention with neochord implantation for degenerative mitral valve disease have been recently introduced in the surgical practice. The procedure is performed under 2D-3D transesophageal echocardiography guidance. Methods: The use of 3D real-time transesophageal echocardiography provides more accurate information than 2D echocardiography only in all the steps of the procedure. In particular 3D echocardiography is mandatory for preoperative assessment of the morphology of the valve, for correct positioning of the neochord on the diseased segment , for the final tensioning of the chordae and for the final evaluation of the surgical result. Result and Conclusion: This article is to outline the technical aspects of the transesophageal echocardiography guidance of the NeoChord procedure showing that the procedure can be performed only with a close and continuous interaction between the anesthesiologist and the cardiac surgeon.

  5. Correlation of contrast agent kinetics between iodinated contrast-enhanced spectral tomosynthesis and gadolinium-enhanced MRI of breast lesions

    International Nuclear Information System (INIS)

    Froeling, Vera; Diekmann, Felix; Renz, Diane M.; Fallenberg, Eva M.; Steffen, Ingo G.; Diekmann, Susanne; Schmitzberger, Florian F.; Lawaczeck, Ruediger

    2013-01-01

    Assessment of contrast agent kinetics in contrast-enhanced MRI (CE-MRI) with gadolinium-containing contrast agents offers the opportunity to predict breast lesion malignancy. The goal of our study was to determine if similar patterns exist for spectral contrast-enhanced digital breast tomosynthesis (CE-DBT) using an iodinated contrast agent. The protocol of our prospective study was approved by the relevant institutional review board and the German Federal Office for Radiation Protection. All patients provided written informed consent. We included 21 women with a mean age of 62.4 years. All underwent ultrasound-guided biopsy of a suspect breast lesion, spectral CE-DBT and CE-MRI. For every breast lesion, contrast agent kinetics was assessed by signal intensity-time curves for spectral CE-DBT and CE-MRI. Statistical comparison used Cohen's kappa and Spearman's rho test. Spearman's rho of 0.49 showed significant (P = 0.036) correlation regarding the contrast agent kinetics in signal intensity-time curves for spectral CE-DBT and CE-MRI. Cohen's kappa indicated moderate agreement (kappa = 0.438). There is a statistically significant correlation between contrast agent kinetics in the signal intensity-time curves for spectral CE-DBT and CE-MRI. Observing intralesional contrast agent kinetics in spectral CE-DBT may aid evaluation of malignant breast lesions. (orig.)

  6. Successful transfemoral aortic Edwards(®) SAPIEN(®) bioprosthesis implantation without using iodinated contrast media in a woman with severe allergy to contrast agent.

    Science.gov (United States)

    Leroux, Lionel; Dijos, Marina; Dos Santos, Pierre

    2013-12-01

    Severe anaphylactoid reaction after the use of iodinated contrast media are rare but can contraindicate the use of contrast agent. It was the case of a 53-year-old woman suffering from symptomatic severe aortic stenosis, recused for cardiac surgery because of deleterious effects of chest-wall irradiation, with porcelain aorta. We decided to implant a 23-mm Edwards(®) SAPIEN(®) transcatheter aortic valve via a femoral route without using any contrast media. The implantation was successful after surgical approach of the femoral artery, transesophageal echocardiography guiding, and localization of native leaflets and coronary trunk with catheters. Immediate and one month post-interventional follow-up was favorable and echocardiography showed a good functioning of the aortic bioprosthesis. Although conventional angiography is the best way to visualize the good positioning of the valve before deployment, our case suggests that, in special situations, transfemoral implantation of an Edwards(®) SAPIEN(®) aortic bioprosthesis is feasible without any contrast injection. Copyright © 2012 Wiley Periodicals, Inc.

  7. Evaluation of left ventricular function and volume in patients with dilated cardiomyopathy: Gated myocardial single-photon emission tomography (SPECT) versus echocardiography

    International Nuclear Information System (INIS)

    Berk, Fatma; Isgoren, S.; Demir, H.; Kozdag, G.; Ural, D.; Komsuoglu, B.

    2005-01-01

    Left ventricular function, volumes and regional wall motion provide valuable diagnostic information and are of long-term prognostic importance in patients with dilated cardiomyopathy (DCM). This study was designed to compare the effectiveness of 2D-echocardiography and gated single-photon emission tomography (SPECT) for evaluation of these parameters in patients with DCM. Gated SPECT and 2D-echocardiography were performed in 33 patients having DCM. Gated SPECT data, including left ventricular ejection fraction (LVEF), were processed using an automated algorithm. Standard technique was used for 2D-echocardiography. Regional wall motion was evaluated using both modalities and was scored by two independent observers using a 16-sement model with a 5-point scoring system. The overall agreement between the two imaging modalities for the assessment of regional wall motion was 56% (298/528 segments). With gated SPECT, LEVF, end-diastolic volume (EDV), and end-diastolic volume (EDV), and end-systolic volume (ESV) were 27+-9%, 217+-73mL, respectively, and 30.8%, 195+-58mL and, 137+-48 mL with echocardiography. The correlation between gated SPECT and 2-D-echocardiography was good (r=0.76, P<0.01) for the assessment of LVEF. The correlation for EDV and ESV were also good, but with wider limits of agreement (r=0.72, P<0.01 and r=0.73, P<0.01, respectively) and significantly higher values were obtained with gated SPECT (P<0.01). Gated SPECT and 2D-echocardiography correlate well for the assessment of LV function and LV volumes. Like 2D-echocardiography, gated SPECT provides reliable information about LV function and dimension with the additional advantage of perfusion data. (author)

  8. Correlation between contrast sensitivity and visual acuity in retinitis pigmentosa patients.

    Science.gov (United States)

    Akeo, Kiyoshi; Hiida, Yoshiki; Saga, Masamichi; Inoue, Rikako; Oguchi, Yoshihisa

    2002-01-01

    High-contrast figures such as Landolt rings are insufficient to evaluate the function of the foveal cones of retinitis pigmentosa (RP) patients. We investigated the correlation between visual function as determined with Landolt rings and with the Vistech Contrast Sensitivity Function Test (VCTS) at various spatial frequencies, in addition to the Cambridge Low Contrast Grating (CLCG). The study included 30 retinitis pigmentosa patients (53 eyes). All patients were assessed with Landolt rings, the Vistech method, and the CLCG. We estimated the relative contribution of contrast sensitivity to visual acuity by VCTS at each spatial frequency and by CLCG by simple linear regression analysis. The results of the regression analysis of VCTS at 1.5, 3.0, and 6.0 cycles/degree showed a significant correlation between Landolt rings and VCTS and between CLCG and VCTS that was strongest at 6.0 cycles/degree. There was no significant correlation between Landolt rings and VCTS or between CLCG and VCTS at 12.0 and 18.0 cycles/degree. Patients with a visual acuity of 20/25 and CLCG greater than 100 were divided into two groups according to their contrast sensitivity at 18.0 cycles/degree on VCTS. The VCTS at the highest frequency was useful for evaluating the foveal visual function in RP patients having good visual acuity with the Landolt rings. Thus, contrast sensitivity should be useful in detecting minute impairment or improvement of visual function in RP. Copyright 2002 S. Karger AG, Basel

  9. Fetal Echocardiography/Your Unborn Baby's Heart

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Fetal Echocardiography / Your Unborn Baby's Heart Updated:Oct 6,2016 ... Your Risk • Symptoms & Diagnosis Introduction Common Tests Fetal Echocardiography/Your Unborn Baby's Heart - Fetal Echocardiogram Test - Detection ...

  10. The Evolutionary Development of Echocardiography

    Science.gov (United States)

    Maleki, Majid; Esmaeilzadeh, Maryam

    2012-01-01

    Echocardiography is a non-invasive diagnostic technique which provides information on cardiac morphology, function, and hemodynamics. It is the most frequently used cardiovascular diagnostic test only after electrocardiography. In less than five decades, the evolution in this technique has made it the basic part of cardiovascular medicine. Herein, the evolution of various forms of echocardiography is briefly described. PMID:23390327

  11. Implementation of the stress echocardiography in an echocardiographic laboratory

    International Nuclear Information System (INIS)

    Solis Brizuela, Felix

    2013-01-01

    The logistics for the implementation of the stress echocardiography is defined with based on current recommendations, for an echocardiography laboratory. The protocols established to perform the studies and procedures of this diagnostic method are exposed. The elementary conditions to realize with safety the stress echocardiography are established. Recent literature on the evaluation of new echocardiographic techniques is reviewed to determine their usefulness in stress testing. The assessment of stress echocardiography is developed. The stress echocardiography has been the procedure with high sensitivity and specificity for the diagnosis of coronary artery disease [es

  12. Transesophageal echocardiography. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Lambertz, Heinz; Lethen, Harald

    2013-01-01

    The book on transesophageal echocardiography covers the following issues: Development of transesophageal echocardiography, technical advances; indications and contraindication for transesophageal echocardiography; systematic of the medical examination process; cardiac valves and valve prostheses; mitral and aortic valvuloplasty, TAVI and interventional treatment of mitral regurgitation; infectious endocarditis; one-way and effluence disturbances of the left and right ventricle; diseases of the thoracic aorta; undefined right ventricle enlargement; lung embolism, acute infarct complications; TEE during anesthesia and perioperative intensive medicine, cardiac sources of embolism; cardiac tumors, mediastinal lymph nodes; pericardiac diseases; congenital heart diseases in childhood and adulthood; catheter interventions and heart valve reconstruction; surgically corrected congenital cardiac defects; intracavitary versus transesophageal echocardiography; three-dimensional TEE; coronary diagnostics; ischemia and vitality diagnostics.

  13. Practical guidance for the implementation of stress echocardiography.

    Science.gov (United States)

    Suzuki, Kengo; Hirano, Yutaka; Yamada, Hirotsugu; Murata, Mitsushige; Daimon, Masao; Takeuchi, Masaaki; Seo, Yoshihiro; Izumi, Chisato; Akaishi, Makoto

    2018-06-06

    Exercise stress testing has been widely undertaken for the diagnosis of heart diseases. The accurate assessment of clinical conditions can be conducted by comparing the findings obtained from the results of stress echocardiography with the changes in the blood/heart rate and electrocardiograms. Numerous overseas studies have reported the utility of stress echocardiography in diagnosing myocardial ischemia; in Japan, the use of this modality for this purpose was included in the national health insurance reimbursable list in 2012. Nevertheless, stress echocardiography is far from being a widespread practice in Japan. This might be due to insufficient equipment (e.g., ergometers, space for test implementation) at each medical institution, shortage of technicians and sonographers who are well experienced and who are responsible for obtaining images during stress testing. The other possible reasons include the limited evidence available in Japan and the lack of a standardized testing protocol. Further dissemination of the practice of exercise stress echocardiography in this country is deemed necessary to establish satisfactory evidence for the use of stress echocardiography in the Japanese population. To this end, efforts are underway to develop a standardized protocol and report format to be adopted throughout Japan. We here present a guideline created by the Guideline Development Committee of the Japanese Society of Echocardiography that describes safe and effective stress echocardiography protocols and report formats. The readers are encouraged to perform exercise stress echocardiography using the proposed template for consensus document and report attached to this guideline.

  14. Carcinoid syndrome diagnosed by echocardiography.

    Science.gov (United States)

    Garg, Scot; Bourantas, Christos V; Nair, Rajesh K; Alamgir, Farqad

    2011-02-17

    Right heart failure is a common presentation to both general physicians and cardiologists. Echocardiography is a useful investigation, and usually imaging of the liver is confined to helping estimate the right atrial pressure. We report a case of right heart failure where incidental imaging of the liver architecture during transoesophageal echocardiography helped in establishing the final diagnosis. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  15. MRI in the diagnosis of non-compacted ventricular Myocardium (NCVM) compared to echocardiography

    International Nuclear Information System (INIS)

    Weiss, F.; Habermann, C.R.; Sievers, J.; Weil, J.; Adam, G.; Lilje, C.; Razek, W.

    2003-01-01

    Purpose: To report the detection of con-compacted ventricular myocardium (NVCM) with MRI compared to echocardiography in 8 patients. Material and methods: Non-compaction of the ventricular myocardium is a congenital disorder characterized by an altered structure of the myocardial wall resulting from an intrauterine arrest in endomyocardial embryogenesis. The morphological findings consist of a prominent meshwork of multiple myocardial trabeculations and deep intertrabecular recesses, communicating with the left ventricular cavity. 8 consecutive patients (mean age 7.3 years) with clinical and echocardiographic signs of NCVM were examined by MRI (1.5 T, Vision, Siemens) in short axis and 2- and 4-chamber views, using T 1 -weighted TSE and Cine-GRE in 6 patients and true FISP sequences in 2 patients. MRI and echocardiography were evaluated for visibility, signs of NCVM and involvement of myocardial wall segments. Thickness was measured for non-compacted and compacted myocardium and the non-compacted to compacted (N/C) ratio calculated. Results: MRI diagnosed 6 of 8 patients of having NCVM. Myocardial thickness as measured by echocardiography and MRI showed a good correlation in compacted myocardium (r = 0.82) and no correlation in non-compacted myocardium (r = 0.4). In 2 cases, non-compacted myocardium was detected, but echocardiography did not reach the N/C ratio > 2 as required to diagnose NCVM in accordance with the criteria found in the literature. Both patients were also misdiagnosed by MRI performed with Cine-GRE. MRI reached a N/C ratio > 2 in only three patients. Newer TruFisp sequences showed no definite advantages. Extent of non-compaction could be visualized correctly with MRI. (orig.) [de

  16. Recent advances in echocardiography for valvular heart disease.

    Science.gov (United States)

    Hahn, Rebecca

    2015-01-01

    Echocardiography is the imaging modality of choice for the assessment of patients with valvular heart disease. Echocardiographic advancements may have particular impact on the assessment and management of patients with valvular heart disease. This review will summarize the current literature on advancements, such as three-dimensional echocardiography, strain imaging, intracardiac echocardiography, and fusion imaging, in this patient population.

  17. Optimal Analysis of Left Atrial Strain by Speckle Tracking Echocardiography: P-wave versus R-wave Trigger.

    Science.gov (United States)

    Hayashi, Shuji; Yamada, Hirotsugu; Bando, Mika; Saijo, Yoshihito; Nishio, Susumu; Hirata, Yukina; Klein, Allan L; Sata, Masataka

    2015-08-01

    Left atrial (LA) strain analysis using speckle tracking echocardiography is useful for assessing LA function. However, there is no established procedure for this method. Most investigators have determined the electrocardiographic R-wave peak as the starting point for LA strain analysis. To test our hypothesis that P-wave onset should be used as the starting point, we measured LA strain using 2 different starting points and compared the strain values with the corresponding LA volume indices obtained by three-dimensional (3D) echocardiography. We enrolled 78 subjects (61 ± 17 years, 25 males) with and without various cardiac diseases in this study and assessed global longitudinal LA strain by two-dimensional speckle tracking strain echocardiography using EchoPac software. We used either R-wave peak or P-wave onset as the starting point for determining LA strains during the reservoir (Rres, Pres), conduit (Rcon, Pcon), and booster pump (Rpump, Ppump) phases. We determined the maximum, minimum, and preatrial contraction LA volumes, and calculated the LA total, passive, and active emptying fractions using 3D echocardiography. The correlation between Pres and LA total emptying fraction was better than the correlation between Rres and LA total emptying fraction (r = 0.458 vs. 0.308, P = 0.026). Pcon and Ppump exhibited better correlation with the corresponding 3D echocardiographic parameters than Rcon (r = 0.560 vs. 0.479, P = 0.133) and Rpump (r = 0.577 vs. 0.345, P = 0.003), respectively. LA strain in any phase should be analyzed using P-wave onset as the starting point rather than R-wave peak. © 2014, Wiley Periodicals, Inc.

  18. Fetal Echocardiography and Indications

    Directory of Open Access Journals (Sweden)

    Melih Atahan Güven

    2008-09-01

    Full Text Available Congenital heart diseases are encountered in 0.8% of live births and are among the most frequently diagnosed malformations. At least half of these anomalies end up with death or require surgical interventions and are responsible for 30% of the perinatal mortality. Fetal echocardiography is the sum of knowledge, skill and orientation rather than knowing the embryologic details of the fetal heart. The purpose of fetal echocardiography is to document the presence of normal fetal cardiac anatomy and rhythm in high risk group and to define the anomaly and arrhythmia if present. A certain sequence should be followed during the evaluation of fetal heart. Sequential segmental analysis (SSA and basic definition terminology made it possible to determine a lot of complex cardiac anomalies during prenatal period. By the end of 1970’s, Shinebourne started using sequential segmental analysis for fetal cardiac evaluation and today, prenatal diagnosis of congenital heart disease is possible without any confusion. In this manner, whole fetal heart can be evaluated as the relation of three segments (atria, ventricles and the great arteries with each other, irrelevant of complexity of a possible cardiac anomaly. Presence of increased nuchal thickness during early gestation and abnormal four-chamber-view during ultrasonography by the obstetrician presents a clear indication for fetal echocardiography,however, one should keep in mind that 80-90% of the babies born with a congenital heart disease do not have a familial or maternal risk factor. In addition, it should be remembered that expectant mothers with diabetes mellitus pose an indication for fetal echocardiography.

  19. Endocarditis : Effects of routine echocardiography during Gram-positive bacteraemia

    NARCIS (Netherlands)

    Vos, F J; Bleeker-Rovers, C P; Sturm, P D; Krabbe, P F M; van Dijk, A P J; Oyen, W J G; Kullberg, B J

    2011-01-01

    BACKGROUND: Despite firm recommendations to perform echocardiography in high-risk patients with Gram-positive bacteraemia, routine echocardiography is not embedded in daily practice in many settings. The aim of this study was to evaluate whether a regime including routine echocardiography results in

  20. Comparison of left ventricular function assessment between echocardiography and MRI in Duchenne muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Buddhe, Sujatha; Lewin, Mark; Olson, Aaron; Soriano, Brian D. [University of Washington School of Medicine and Seattle Children' s Hospital, Division of Cardiology, Department of Pediatrics, Seattle, WA (United States); Ferguson, Mark [University of Washington School of Medicine and Seattle Children' s Hospital, Department of Radiology, Seattle, WA (United States)

    2016-09-15

    Cardiomyopathy in Duchenne muscular dystrophy (DMD) is associated with death in approximately 40% of patients. Echocardiography is routinely used to assess left ventricular (LV) function; however, it has limitations in these patients. We compared echocardiographic measures of cardiac function assessment to cardiac MRI. We included children and young adults with DMD who had MRI performed between January 2010 and July 2015. We measured echocardiographic and MRI parameters of function assessment, including strain. Presence of late gadolinium enhancement (LGE) was assessed by MRI. Subjects were divided into two groups based on MRI left ventricular ejection fraction (LVEF): group I, LVEF ≥55% and group II, LVEF <55%. We included 41 studies in 33 subjects, with 25 in group I and 16 in group II. Mean age of subjects was 13.6 ± 2.8 years and mean duration between echocardiogram and MRI was 7.6 ± 4.1 months. Only 8 of 16 (50%) patients in group II had diminished function on echocardiogram. Echocardiographic images were suboptimal in 16 subjects (39%). Overall, echocardiographic parameters had weak correlation with MRI-derived ejection fraction percentage. MRI-derived myocardial strain assessment has better correlation with MRI ejection fraction as compared to echocardiography-derived strain parameters. Echocardiography-based ventricular functional assessment has weak correlation with MRI parameters in children and young adults with Duchenne muscular dystrophy. While this correlation improves in the subset of subjects with adequate echocardiographic image quality, it remains modest and potentially suboptimal for clinical management. Accordingly, we conclude that MRI should be performed routinely and early in children with DMD, not only for LGE imaging but also for functional assessment. (orig.)

  1. Comparison of left ventricular function assessment between echocardiography and MRI in Duchenne muscular dystrophy

    International Nuclear Information System (INIS)

    Buddhe, Sujatha; Lewin, Mark; Olson, Aaron; Soriano, Brian D.; Ferguson, Mark

    2016-01-01

    Cardiomyopathy in Duchenne muscular dystrophy (DMD) is associated with death in approximately 40% of patients. Echocardiography is routinely used to assess left ventricular (LV) function; however, it has limitations in these patients. We compared echocardiographic measures of cardiac function assessment to cardiac MRI. We included children and young adults with DMD who had MRI performed between January 2010 and July 2015. We measured echocardiographic and MRI parameters of function assessment, including strain. Presence of late gadolinium enhancement (LGE) was assessed by MRI. Subjects were divided into two groups based on MRI left ventricular ejection fraction (LVEF): group I, LVEF ≥55% and group II, LVEF <55%. We included 41 studies in 33 subjects, with 25 in group I and 16 in group II. Mean age of subjects was 13.6 ± 2.8 years and mean duration between echocardiogram and MRI was 7.6 ± 4.1 months. Only 8 of 16 (50%) patients in group II had diminished function on echocardiogram. Echocardiographic images were suboptimal in 16 subjects (39%). Overall, echocardiographic parameters had weak correlation with MRI-derived ejection fraction percentage. MRI-derived myocardial strain assessment has better correlation with MRI ejection fraction as compared to echocardiography-derived strain parameters. Echocardiography-based ventricular functional assessment has weak correlation with MRI parameters in children and young adults with Duchenne muscular dystrophy. While this correlation improves in the subset of subjects with adequate echocardiographic image quality, it remains modest and potentially suboptimal for clinical management. Accordingly, we conclude that MRI should be performed routinely and early in children with DMD, not only for LGE imaging but also for functional assessment. (orig.)

  2. Application of Echocardiography on Transgenic Mice with Cardiomyopathies

    Directory of Open Access Journals (Sweden)

    G. Chen

    2012-01-01

    Full Text Available Cardiomyopathies are common cardiac disorders that primarily affect cardiac muscle resulting in cardiac dysfunction and heart failure. Transgenic mouse disease models have been developed to investigate the cellular mechanisms underlying heart failure and sudden cardiac death observed in cardiomyopathy cases and to explore the therapeutic outcomes in experimental animals in vivo. Echocardiography is an essential diagnostic tool for accurate and noninvasive assessment of cardiac structure and function in experimental animals. Our laboratory has been among the first to apply high-frequency research echocardiography on transgenic mice with cardiomyopathies. In this work, we have summarized our and other studies on assessment of systolic and diastolic dysfunction using conventional echocardiography, pulsed Doppler, and tissue Doppler imaging in transgenic mice with various cardiomyopathies. Estimation of embryonic mouse hearts has been performed as well using this high-resolution echocardiography. Some technical considerations in mouse echocardiography have also been discussed.

  3. Handheld echocardiography during hospitalization for acute myocardial infarction.

    Science.gov (United States)

    Cullen, Michael W; Geske, Jeffrey B; Anavekar, Nandan S; Askew, J Wells; Lewis, Bradley R; Oh, Jae K

    2017-11-01

    Handheld echocardiography (HHE) is concordant with standard transthoracic echocardiography (TTE) in a variety of settings but has not been thoroughly compared to traditional TTE in patients with acute myocardial infarction (AMI). Completed by experienced operators, HHE provides accurate diagnostic capabilities compared with standard TTE in AMI patients. This study prospectively enrolled patients admitted to the coronary care unit with AMI. Experienced sonographers performed HHE with a V-scan. All patients underwent clinical TTE. Each HHE was interpreted by 2 experts blinded to standard TTE. Agreement was assessed with κ statistics and concordance correlation coefficients. Analysis included 82 patients (mean age, 66 years; 74% male). On standard TTE, mean left ventricular (LV) ejection fraction was 46%. Correlation coefficients between HHE and TTE were 0.75 (95% confidence interval: 0.66 to 0.82) for LV ejection fraction and 0.69 (95% confidence interval: 0.58 to 0.77) for wall motion score index. The κ statistics ranged from 0.47 to 0.56 for LV enlargement, 0.55 to 0.79 for mitral regurgitation, and 0.44 to 0.57 for inferior vena cava dilatation. The κ statistics were highest for the anterior (0.81) and septal (0.71) apex and lowest for the mid inferolateral (0.36) and basal inferoseptal (0.36) walls. In patients with AMI, HHE and standard TTE demonstrate good correlation for LV function and wall motion. Agreement was less robust for structural abnormalities and specific wall segments. In experienced hands, HHE can provide a focused assessment of LV function in patients hospitalized with AMI; however, HHE should not substitute for comprehensive TTE. © 2017 Wiley Periodicals, Inc.

  4. Transesofagic echocardiography in the study of patient with cerebrovascular events in who origin cardiovascular embolic is suspected

    International Nuclear Information System (INIS)

    Escobar Q, Carlos I; Jaramillo U, Mario; Tenorio, Luis F; Molina V, Claudia; Saldarriaga A, Marcela; Arango, Angela M

    2003-01-01

    Cerebrovascular events have an enormous social and economic impact. Twenty percent are of cardiac embolic origin and thirty five percent are of unknown cause or cryptogenic. In the cryptogenic group some echocardiographic findings could explain a cardiovascular origin. Echocardiography helps to study 55% of patients with cerebrovascular accidents. We present our experience during ten years since December 1992 to May 2002 in the Santa Maria cardiovascular clinic with 866 patients, 416 women and 450 men, mean age of 62:1:15 years. The five most frequent diagnoses were: aortic atheromatosis (34%), dilated cardiopathy (8.2%), ischemic cardiopathy (8.2%), left atrial spontaneous contrast (8%), patent foramen ovale (7.7%) and atrial septal aneurysm (4.5%). thirty percent of this population had a normal study. echocardiography helped to guide most of the patient's treatment. there was one esophagus rupture and fifteen minor oropharinx hemorrhages. Trans esophageal echocardiography is a very useful diagnostic method in this patient's study

  5. What every radiologist should know about paediatric echocardiography

    International Nuclear Information System (INIS)

    Sorantin, Erich; Heinzl, Bernd

    2014-01-01

    Congenital heart defects (CHD) occur in less than one percent of all newborns. Echocardiography represents the imaging modality of choice for morphological and functional assessment. In childhood the different CHD types can be diagnosed trustfully and can be performed bedside. In the follow-up of CHD cross sectional imaging plays an important role and therefore it is essential for the radiologist to know the features, challenges and limitations of echocardiography. Within this review article a systematic approach for morphological and functional assessment of the heart will is given along with representative example images. In addition, typical echocardiographic findings in common CHD is presented. In older children, adolescents and grown-ups with CHD (GUCH) echocardiography suffers from limitations – partially due to skeletal deformations and lung emphysema. In particular right ventricular function assessment is not always possible by echocardiography. Therefore strengths and limitations of echocardiography will be discussed the role of cardiac magnetic resonance imaging (cMRI) and cardiac computed tomography (cCT) emphasized

  6. What every radiologist should know about paediatric echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Sorantin, Erich, E-mail: erich.sorantin@medunigraz.at [Division of Pediatric Radiology, Department of Radiology, Medical University Graz, Auenbruggerplatz 34, A-8036 Graz (Austria); Heinzl, Bernd [Division of Pediatric Cardiology, Department of Pediatric and Adolescent Medicine, Medical University Graz, Auenbruggerplatz 34, A-8036 Graz (Austria)

    2014-09-15

    Congenital heart defects (CHD) occur in less than one percent of all newborns. Echocardiography represents the imaging modality of choice for morphological and functional assessment. In childhood the different CHD types can be diagnosed trustfully and can be performed bedside. In the follow-up of CHD cross sectional imaging plays an important role and therefore it is essential for the radiologist to know the features, challenges and limitations of echocardiography. Within this review article a systematic approach for morphological and functional assessment of the heart will is given along with representative example images. In addition, typical echocardiographic findings in common CHD is presented. In older children, adolescents and grown-ups with CHD (GUCH) echocardiography suffers from limitations – partially due to skeletal deformations and lung emphysema. In particular right ventricular function assessment is not always possible by echocardiography. Therefore strengths and limitations of echocardiography will be discussed the role of cardiac magnetic resonance imaging (cMRI) and cardiac computed tomography (cCT) emphasized.

  7. Feasibility of electron beam tomography in diagnosis of congenital heart disease: comparison with echocardiography

    International Nuclear Information System (INIS)

    Lee, Jongmin J.; Kang, Duk-Sik

    2001-01-01

    Objective: To evaluate the feasibility of electron beam tomography (EBT) for morphological assessment of congenital heart disease. Materials and methods: Sixteen subjects were examined by EBT, transthoracic echocardiography, cardiac cine angiography and surgery. EBT scan was performed using single slice continuous volume mode to acquire high-resolution static image. Double dose contrast medium was injected by bolus technique after measuring scan delay time and calculation of proper injection rate. The results of EBT and echocardiography were compared based on the results of cardiac cine angiography and surgical findings. All anomalous components were evaluated in all subjects and grouped according to major cardiac structures. Statistical analysis was performed to compare two modalities' ability to evaluate the anomalies of major structures. Results: EBT was more sensitive to evaluate the anomalies of systemic vessels, pulmonary vessels and small systemic arteries such as coronary artery. EBT was less sensitive to identify the abnormality of cardiac valves such as valvular regurgitation. There was no difference of sensitivity in evaluation of cardiac chambers and septa between the two modalities. Conclusion: EBT assisted by transthoracic echocardiography is excellent noninvasive modality to diagnose congenital heart disease

  8. Echocardiography and cardiac resynchronisation therapy, friends or foes?

    Science.gov (United States)

    van Everdingen, W M; Schipper, J C; van 't Sant, J; Ramdat Misier, K; Meine, M; Cramer, M J

    2016-01-01

    Echocardiography is used in cardiac resynchronisation therapy (CRT) to assess cardiac function, and in particular left ventricular (LV) volumetric status, and prediction of response. Despite its widespread applicability, LV volumes determined by echocardiography have inherent measurement errors, interobserver and intraobserver variability, and discrepancies with the gold standard magnetic resonance imaging. Echocardiographic predictors of CRT response are based on mechanical dyssynchrony. However, parameters are mainly tested in single-centre studies or lack feasibility. Speckle tracking echocardiography can guide LV lead placement, improving volumetric response and clinical outcome by guiding lead positioning towards the latest contracting segment. Results on optimisation of CRT device settings using echocardiographic indices have so far been rather disappointing, as results suffer from noise. Defining response by echocardiography seems valid, although re-assessment after 6 months is advisable, as patients can show both continuous improvement as well as deterioration after the initial response. Three-dimensional echocardiography is interesting for future implications, as it can determine volume, dyssynchrony and viability in a single recording, although image quality needs to be adequate. Deformation patterns from the septum and the derived parameters are promising, although validation in a multicentre trial is required. We conclude that echocardiography has a pivotal role in CRT, although clinicians should know its shortcomings.

  9. Performance of two-dimensional Doppler echocardiography for the assessment of infarct size and left ventricular function in rats

    Directory of Open Access Journals (Sweden)

    Nozawa E.

    2006-01-01

    Full Text Available Although echocardiography has been used in rats, few studies have determined its efficacy for estimating myocardial infarct size. Our objective was to estimate the myocardial infarct size, and to evaluate anatomic and functional variables of the left ventricle. Myocardial infarction was produced in 43 female Wistar rats by ligature of the left coronary artery. Echocardiography was performed 5 weeks later to measure left ventricular diameter and transverse area (mean of 3 transverse planes, infarct size (percentage of the arc with infarct on 3 transverse planes, systolic function by the change in fractional area, and diastolic function by mitral inflow parameters. The histologic measurement of myocardial infarction size was similar to the echocardiographic method. Myocardial infarct size ranged from 4.8 to 66.6% when determined by histology and from 5 to 69.8% when determined by echocardiography, with good correlation (r = 0.88; P < 0.05; Pearson correlation coefficient. Left ventricular diameter and mean diastolic transverse area correlated with myocardial infarct size by histology (r = 0.57 and r = 0.78; P < 0.0005. The fractional area change ranged from 28.5 ± 5.6 (large-size myocardial infarction to 53.1 ± 1.5% (control and correlated with myocardial infarct size by echocardiography (r = -0.87; P < 0.00001 and histology (r = -0.78; P < 00001. The E/A wave ratio of mitral inflow velocity for animals with large-size myocardial infarction (5.6 ± 2.7 was significantly higher than for all others (control: 1.9 ± 0.1; small-size myocardial infarction: 1.9 ± 0.4; moderate-size myocardial infarction: 2.8 ± 2.3. There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats.

  10. Clinical Stress Echocardiography

    NARCIS (Netherlands)

    S.E. Karagiannis

    2007-01-01

    textabstractTwo-dimensional echocardiography is a commonly used non-invasive method for the assessment of left ventricular function. It provides precise information on both global and segmental myocardial function by displaying endocardial motion and wall thickening. Dobutamine stress

  11. Speckle contrast diffuse correlation tomography of complex turbid medium flow

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Chong; Irwin, Daniel; Lin, Yu; Shang, Yu; He, Lian; Kong, Weikai; Yu, Guoqiang [Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky 40506 (United States); Luo, Jia [Department of Pharmacology and Nutritional Sciences, University of Kentucky, Lexington, Kentucky 40506 (United States)

    2015-07-15

    Purpose: Developed herein is a three-dimensional (3D) flow contrast imaging system leveraging advancements in the extension of laser speckle contrast imaging theories to deep tissues along with our recently developed finite-element diffuse correlation tomography (DCT) reconstruction scheme. This technique, termed speckle contrast diffuse correlation tomography (scDCT), enables incorporation of complex optical property heterogeneities and sample boundaries. When combined with a reflectance-based design, this system facilitates a rapid segue into flow contrast imaging of larger, in vivo applications such as humans. Methods: A highly sensitive CCD camera was integrated into a reflectance-based optical system. Four long-coherence laser source positions were coupled to an optical switch for sequencing of tomographic data acquisition providing multiple projections through the sample. This system was investigated through incorporation of liquid and solid tissue-like phantoms exhibiting optical properties and flow characteristics typical of human tissues. Computer simulations were also performed for comparisons. A uniquely encountered smear correction algorithm was employed to correct point-source illumination contributions during image capture with the frame-transfer CCD and reflectance setup. Results: Measurements with scDCT on a homogeneous liquid phantom showed that speckle contrast-based deep flow indices were within 12% of those from standard DCT. Inclusion of a solid phantom submerged below the liquid phantom surface allowed for heterogeneity detection and validation. The heterogeneity was identified successfully by reconstructed 3D flow contrast tomography with scDCT. The heterogeneity center and dimensions and averaged relative flow (within 3%) and localization were in agreement with actuality and computer simulations, respectively. Conclusions: A custom cost-effective CCD-based reflectance 3D flow imaging system demonstrated rapid acquisition of dense boundary

  12. Aortic obstruction: anatomy and echocardiography

    Directory of Open Access Journals (Sweden)

    Keirns Candace

    2006-09-01

    Full Text Available Abstract Echocardiography is a valuable non-invasive technique for identifying the site and type of aortic obstruction. Knowledge of the morphological details of each type of obstruction is the basis for correct interpretation of the diagnostic images and clinical decisions. This study was undertaken to correlate the echocardiographic images with anatomic specimens of equivalent valvular and supravalvular aortic obstruction. Specimens were part of the collection of the Department of Embryology. Fifty six patients were studied, and forty specimens with aortic obstruction were analyzed. Echocardiographic characteristics: Thirty one (55.3% patients were women and twenty five (44.7% men. Valvular aortic obstruction was found in Thirty six patients (64.3 % and supravalvular aortic obstruction in twenty (35.7%. Anatomic characteristics: Of the forty specimens examined, twenty one (52.5% had valvular aortic obstruction and nineteen (47.5% supravalvular aortic obstruction. The anatomoechocardiographic correlation clearly showed that the anatomic findings of the specimen hearts and aortas corresponded to echocardiographic images of valvular and supravalvular aortic obstruction and provided solid corroboration of echocardiographic diagnoses.

  13. The Myocardial Ischemia Evaluated by Real-Time Contrast Echocardiography May Predict the Response to Cardiac Resynchronization Therapy: A Large Animal Study

    Science.gov (United States)

    Chen, Yongle; Cheng, Leilei; Yao, Haohua; Chen, Haiyan; Wang, Yongshi; Zhao, Weipeng; Pan, Cuizhen; Shu, Xianhong

    2014-01-01

    Evidence-based criteria for applying cardiac resynchronization therapy (CRT) in patients with ischemic cardiomyopathy are still scarce. The aim of the present study was to evaluate the predictive value of real-time myocardial contrast echocardiography (RT-MCE) in a preclinical canine model of ischemic cardiomyopathy who received CRT. Ischemic cardiomyopathy was produced by ligating the first diagonal branch in 20 beagles. Dogs were subsequently divided into two groups that were either treated with bi-ventricular pacing (CRT group) or left untreated (control group). RT-MCE was performed at baseline, before CRT, and 4 weeks after CRT. Two-dimensional speckle tracking imaging was used to evaluate the standard deviation of circumferential (Cir12SD), radial (R12SD), and longitudinal (L12SD) strains of left ventricular segments at basal as well as middle levels. Four weeks later, the Cir12SD, R12SD, and myocardial blood flow (MBF) of the treated group were significantly improved compared to their non-CRT counterparts. Furthermore, MBF values measured before CRT were significantly higher in responders than in non-responders to bi-ventricular pacing. Meanwhile, no significant differences were observed between the responder and non-responder groups in terms of Cir12SD, R12SD, and L12SD. A high degree of correlation was found between MBF values before CRT and LVEF after CRT. When MBF value>24.9 dB/s was defined as a cut-off point before CRT, the sensitivity and specificity of RT-MCE in predicting the response to CRT were 83.3% and 100%, respectively. Besides, MBF values increased significantly in the CRT group compared with the control group after 4 weeks of pacing (49.8±15.5 dB/s vs. 28.5±4.6 dB/s, p<0.05). Therefore, we considered that myocardial perfusion may be superior to standard metrics of LV synchrony in selecting appropriate candidates for CRT. In addition, CRT can improve myocardial perfusion in addition to cardiac synchrony, especially in the setting of ischemic

  14. MODERN POSSIBILITIES OF SPECKLE TRACKING ECHOCARDIOGRAPHY IN CLINICAL PRACTICE

    Directory of Open Access Journals (Sweden)

    V. S. Nikiforov

    2017-01-01

    Full Text Available Speckle-tracking echocardiography is promising modern technique for evaluation of structural and functional changes in the myocardium. It evaluates the indicator of global longitudinal myocardial deformation, which is more sensitive than ejection fraction to early changes of left ventricular contractility. The diagnostic capabilities of speckle tracking echocardiography are reflected in clinical recommendations and consensus statements of European Society of Cardiology (ESC, European Association of Cardiovascular Imaging (EACVI and American Society of Echocardiography (ASE. The aim of this paper is describe basic principles of speckle tracking echocardiography and clinical applications of this new technology. Attention is paid to the use of speckle tracking echocardiography in such heart pathologies as heart failure, coronary heart disease and myocardial infarction, left ventricular hypertrophy in arterial hypertension, hypertrophic cardiomyopathy and amyloidosis of the heart, valvular heart disease, constrictive pericarditis and cancer therapy-induced cardiotoxicity.

  15. Global and regional left ventricular function: a comparison between gated SPECT, 2D echocardiography and multi-slice computed tomography

    International Nuclear Information System (INIS)

    Henneman, Maureen M.; Bax, Jeroen J.; Holman, Eduard R.; Schuijf, Joanne D.; Jukema, J.W.; Wall, Ernst E. van der; Stokkel, Marcel P.M.; Lamb, Hildo J.; Roos, Albert de

    2006-01-01

    Global and regional left ventricular (LV) function are important indicators of the cardiac status in patients with coronary artery disease (CAD). Therapy and prognosis are to a large extent dependent on LV function. Multi-slice computed tomography (MSCT) has already earned its place as an imaging modality for non-invasive assessment of the coronary arteries, but since retrospective gating to the patient's ECG is performed, information on LV function can be derived. In 49 patients with known or suspected CAD, coronary angiography with MSCT imaging was performed, in addition to gated SPECT and 2D echocardiography. LV end-diastolic and LV end-systolic volumes and LV ejection fraction were analysed with dedicated software (CMR Analytical Software System, Medis, Leiden, The Netherlands for MSCT; gated SPECT by QGS, Cedars-Sinai Medical Center, Los Angeles, CA, USA), and by the biplane Simpson's rule for 2D echocardiography. Regional wall motion was evaluated according to a 17-segment model and a three-point score system. Correlations were fairly good between gated SPECT and MSCT (LVEDV: r=0.65; LVESV: r=0.63; LVEF: r=0.60), and excellent between 2D echocardiography and MSCT (LVEDV: r=0.92; LVESV: r=0.93; LVEF: r=0.80). Agreement for regional wall motion was 95% (κ=0.66) between gated SPECT and MSCT, and 96% (κ=0.73) between 2D echocardiography and MSCT. Global and regional LV function and LV volumes can be adequately assessed with MSCT. Correlations with 2D echocardiography are stronger than with gated SPECT. (orig.)

  16. Four-dimensional echocardiography area strain combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis.

    Science.gov (United States)

    Deng, Yan; Peng, Long; Liu, Yuan-Yuan; Yin, Li-Xue; Li, Chun-Mei; Wang, Yi; Rao, Li

    2017-09-01

    The aim of this prospective study was to assess the diagnosis value of four-dimensional echocardiography area strain (AS) combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis. Based on treadmill exercise load status, two-dimensional conventional echocardiography and four-dimensional echocardiography area strain were performed on patients suspected coronary artery disease before coronary angiogram. Thirty patients (case group) with mild left anterior descending coronary artery stenosis (stenosis Four-dimensional echocardiography area strain combined with exercise stress echocardiography could sensitively find left ventricular regional systolic function abnormality in patients with mild single vessel coronary artery stenosis, and locate stenosis coronary artery accordingly. © 2017, Wiley Periodicals, Inc.

  17. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2014-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  18. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2015-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/ critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  19. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2015-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  20. Comparison of Hyperemic Impedance Echocardiography with Dobutamine Stress Echocardiography to Detect Inducible Myocardial Ischemia: A Pilot Study.

    Science.gov (United States)

    Patel, Jijibhoy J; Gupta, Ankur; Nanda, Navin C

    2016-03-01

    Stress echocardiography using exercise or pharmacological stressors is either contraindicated or associated with significant side effects in some patients. This pilot study was designed to evaluate a new technique, hyperemic impedance echocardiography (HIE). It is based on reactive coronary hyperemia when transient limb ischemia is induced by tourniquet inflation. We hypothesized that this physiologic coronary hyperemia can identify inducible myocardial ischemia by assessment of regional wall motion abnormalities on echocardiography when compared with dobutamine stress echocardiography (DSE). Twenty consecutive outpatients with suspected stable coronary artery disease (CAD) who underwent clinically indicated DSE were recruited for performance of HIE after informed consent was obtained. Standard graded dobutamine infusion protocol from 5 to 40 μg/kg per min was used for DSE. HIE was performed by inflating tourniquets at a pressure of 10 mmHg below the systolic blood pressure for 1 minute in three of four extremities at a time for total of four cycles. Echocardiography was performed immediately after the last rotating tourniquet deflation. DSE and HIE were classified as abnormal for development of new or worsening wall motion abnormality in at least one myocardial segment. Test characteristics were also determined for a subset of these patients (n = 12) who underwent clinically indicated coronary angiography. Hyperemic impedance echocardiography showed 86% sensitivity, 67% specificity, 86% positive predictive value, and 67% negative predictive value with a test accuracy of 80% to detect inducible myocardial wall motion abnormalities when compared with DSE. HIE also showed 83% sensitivity, 75% negative predictive value with a test accuracy of 66.7% for detection of significant (≥50% diameter stenosis) CAD on coronary angiography. In this pilot study, HIE was a feasible, safe, and promising method for detection of inducible myocardial ischemia by assessment of

  1. MRI and echocardiography in the diagnosis of cardiac amyloidosis

    International Nuclear Information System (INIS)

    Wang Jing; Kong Xiangquan; Zhou Guofeng; Xu Haibo; Chang Dandan; Feng Yiming; Liu Dingxi; Zhang Li; Xie Mingxing

    2010-01-01

    Objective: To assess the values of MRI and echocardiography for the diagnosis of cardiac amyloidosis (CA). Methods: Eleven cases with CA proved pathologically performed MRI and echocardiography, the findings were analyzed retrospectively. Results: The characteristic features of cardiac amyloidosis on MRI and echocardiography were: diffuse slight myocardial thickening of the left ventricular wall and interventricular septum (11 cases), slight myocardial thickening of the interatrial septum (5 cases), increased left ventricular mass (7 cases), enlarged left atrium (7 cases), impaired ventricular systolic and diastolic function (10 cases), pleural and pericardial effusions (11 and 9 cases). Echocardiography showed that myocardium was hyperechoic and presented as ground glass with some spotty hyperechoes in 6 cases. MRI revealed a distinct diffuse delayed enhancement of subendocardial and entire myocardium in 8 cases. Conclusion: Doppler echocardiography is the first-choice imaging technique and cardiac magnetic resonance imaging can provide more information for the diagnosis of CA. (authors)

  2. The use of echocardiography in Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Cai, Qiangjun; Shuraih, Mossaab; Nagueh, Sherif F

    2012-04-01

    Endocardial mapping and radiofrequency catheter ablation are well established modalities for the diagnosis and treatment of patients with Wolff-Parkinson-White (WPW) syndrome associated with tachyarrhythmias. However, the electrophysiologic techniques are invasive, require radiation exposure, and lack spatial resolution of cardiac structures. A variety of echocardiographic techniques have been investigated as a non-invasive alternative for accessory pathway localization. Conventional M-mode echocardiography can detect the fine premature wall motion abnormalities associated with WPW syndrome. However, it is unable to identify the exact site of accessory pathway with sufficient accuracy. 2D, 2D-guided M-mode, and 2D phase analysis techniques are limited by image quality and endocardial border definition. Various modalities of tissue Doppler echocardiography significantly increase the accuracy of left-sided accessory pathway localization to 80-90% even in patients with poor acoustic window. However, right-sided pathways remain a diagnostic challenge. Strain echocardiography by speckle tracking has recently been evaluated and appears promising. Different cardiac abnormalities have been detected by echocardiography in WPW patients. Patients with WPW syndrome and tachyarrhythmias have impaired systolic and diastolic function which improves after radiofrequency ablation. Echocardiography is useful in identifying patient with accessory pathway-associated left ventricular dyssynchrony and dysfunction who may benefit from ablation therapy. Transesophageal and intracardiac echocardiography have been used to guide ablation procedure. Ablation-related complications detected by routine echocardiography are infrequent, rarely clinically relevant, and of limited value.

  3. Quantification in echocardiography

    NARCIS (Netherlands)

    Korsten, H.H.M.; Mischi, M.; Grouls, R.J.E.; Jansen, A.H.M.; Dantzig, van J.M.; Peels, C.H.

    2006-01-01

    Until recently, more than 2200 Swan Ganz catheters were used annually in the operating rooms (OR) and intensive care unit (ICU) of the Catharina Hospital in Eindhoven, The Netherlands. After cardiologists who were specialists in echocardiography (ECHO) trained anesthesiologists in ECHO, the need for

  4. Systematic review of cardiac output measurements by echocardiography vs. thermodilution

    DEFF Research Database (Denmark)

    Wetterslev, Mik; Møller-Sørensen, Hasse; Johansen, Rasmus Rothmann

    2016-01-01

    PURPOSE: Echocardiography is frequently used in the hemodynamic evaluation of critically ill patients, but inaccurate measurements may lead to wrong clinical decisions. The aim of our systematic review was to investigate the interchangeability of echocardiography with thermodilution technique...... of the studies assessed left-sided heart structures and the majority had small bias, wide limits of agreement, and high percentage error between echocardiography and thermodilution. In only two of the 24 studies the precision of each technique (echocardiography and thermodilution) was assessed before comparing...... them. In the single study evaluating trending ability using valid methodology, agreement was observed between echocardiography and thermodilution in detecting the directional changes in cardiac output, but the magnitude of changes varied considerably. CONCLUSIONS: The majority of studies comparing...

  5. Right ventricle performances with echocardiography and 99mTc myocardial perfusion imaging in pulmonary arterial hypertension patients.

    Science.gov (United States)

    Liu, Jie; Fei, Lei; Huang, Guang-Qing; Shang, Xiao-Ke; Liu, Mei; Pei, Zhi-Jun; Zhang, Yong-Xue

    2018-05-01

    Right heart catheterization is commonly used to measure right ventricle hemodynamic parameters and is the gold standard for pulmonary arterial hypertension diagnosis; however, it is not suitable for patients' long-term follow-up. Non-invasive echocardiography and nuclear medicine have been applied to measure right ventricle anatomy and function, but the guidelines for the usefulness of clinical parameters remain to be established. The goal of this study is to identify reliable clinical parameters of right ventricle function in pulmonary arterial hypertension patients and analyze the relationship of these clinical parameters with the disease severity of pulmonary arterial hypertension. In this study, 23 normal subjects and 23 pulmonary arterial hypertension patients were recruited from January 2015 to March 2016. Pulmonary arterial hypertension patients were classified into moderate and severe pulmonary arterial hypertension groups according to their mean pulmonary arterial pressure levels. All the subjects were subjected to physical examination, chest X-ray, 12-lead electrocardiogram, right heart catheterization, two-dimensional echocardiography, and technetium 99m ( 99m Tc) myocardial perfusion imaging. Compared to normal subjects, the right heart catheterization indexes including right ventricle systolic pressure, right ventricle end diastolic pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, pulmonary vascular resistance, and right ventricle end systolic pressure increased in pulmonary arterial hypertension patients and were correlated with mean pulmonary arterial pressure levels. Echocardiography parameters, including tricuspid regurgitation peak velocity, tricuspid regurgitation pressure gradient, tricuspid annular plane systolic excursion and fractional area, right ventricle-myocardial performance index, were significantly associated with the mean pulmonary arterial pressure levels in pulmonary arterial hypertension patients

  6. Acute myocarditis with normal wall motion detected with 2D speckle tracking echocardiography

    Directory of Open Access Journals (Sweden)

    Thomas Sturmberger

    2016-05-01

    Full Text Available We present the case of a 26-year-old male with acute tonsillitis who was referred for coronary angiography because of chest pain, elevated cardiac biomarkers, and biphasic T waves. The patient had no cardiovascular risk factors. Echocardiography showed no wall motion abnormalities and no pericardial effusion. 2D speckle tracking revealed distinct decreased regional peak longitudinal systolic strain in the lateral and posterior walls. Ischemic disease was extremely unlikely in view of his young age, negative family history regarding coronary artery disease, and lack of regional wall motion abnormalities on the conventional 2D echocardiogram. Coronary angiography was deferred as myocarditis was suspected. To confirm the diagnosis, cardiac magnetic resonance tomography (MRT was performed, showing subepicardial delayed hyperenhancement in the lateral and posterior walls correlating closely with the strain pattern obtained by 2D speckle tracking echocardiography. With a working diagnosis of acute myocarditis associated with acute tonsillitis, we prescribed antibiotics and nonsteroidal anti-inflammatory drugs. The patient’s clinical signs resolved along with normalization of serum creatine kinase (CK levels, and the patient was discharged on the third day after admission. Learning points: • Acute myocarditis can mimic acute coronary syndromes. • Conventional 2D echocardiography lacks specific features for detection of subtle regional wall motion abnormalities. • 2D speckle tracking expands the scope of echocardiography in identifying myocardial dysfunction derived from edema in acute myocarditis.

  7. Anatomical features of acute mitral valve repair dysfunction: Additional value of three-dimensional echocardiography.

    Science.gov (United States)

    Derkx, Salomé; Nguyen, Virginia; Cimadevilla, Claire; Verdonk, Constance; Lepage, Laurent; Raffoul, Richard; Nataf, Patrick; Vahanian, Alec; Messika-Zeitoun, David

    2017-03-01

    Recurrence of mitral regurgitation after mitral valve repair is correlated with unfavourable left ventricular remodelling and poor outcome. This pictorial review describes the echocardiographic features of three types of acute mitral valve repair dysfunction, and the additional value of three-dimensional echocardiography. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    Science.gov (United States)

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  9. Manual Intracardiac Electrogram Method Is Accurate Alternative to Echocardiography for Atrioventricular and Interventricular Optimization in Cardiac Resynchronization Therapy.

    Science.gov (United States)

    Pezo Nikolić, Borka; Lovrić, Daniel; Ljubas Maček, Jana; Rešković Lukšić, Vlatka; Matasić, Richard; Šeparović Hanževački, Jadranka

    2017-12-01

    Some manufacturers do not provide automated intracardiac electrogram method (IEGM) systems for atrioventricular (AV) and interventricular (VV) delay optimization in cardiac resynchronization therapy (CRT). We aimed to evaluate the accuracy of manual IEGM method in 48 patients previously implanted with Medtronic Syncra CRT. All patients underwent standard device interrogation followed by CRT optimization by IEGM method and by echocardiography one month after implantation. The patient mean age was 60.7±11.8 years and there were 33 (68.8%) males. After CRT implantation, the left ventricular ejection fraction increased from 28.0±7.9% to 39.1±11.0% (p<0.001). Optimal aortic flow Velocity Time Integral (aVTI) was obtained when VV was set to 20-50 ms left ventricular pre-activation. There was a strong correlation between VV values determined by echocardiography and IEGM (R=0.823, p<0.001). We found no significant difference in AV, VV and aVTI values between echocardiography and IEGM method. However, IEGM was significantly less time-consuming than echocardiography [20 (10-28) vs. 40 (35-60) minutes, p<0.001]. Manual IEGM method may be good alternative to echocardiography and automated IEGM method. It also emphasizes the need for implementation of automated IEGM systems in as many CRT devices as possible.

  10. Gated 99mTc-MIBI single-photon emission computed tomography for the evaluation of left ventricular ejection fraction. Comparison with three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Lipiec, P.; Wejner-Mik, P.; Krzeminska-Pakula, M.; Kapusta, A.; Kasprzak, J.D.; Kusmierek, J.; Plachcinska, A.; Szuminski, R.

    2008-01-01

    Parameters of left ventricular systolic function directly influence the management of patients with suspected coronary artery disease (CAD). Quantitative gated single-photon emission computed tomography (QGS; Cedars-Sinai Medical Center, Los Angeles, CA, USA) allows the computation of left ventricular ejection fraction (LVEF) from myocardial perfusion imaging studies which are frequently performed on patients with suspected CAD. Three-dimensional (3D) echocardiography is considered to be the echocardiographic ''gold standard'' for the quantification of LVEF. We sought to compare QGS with 3D echocardiography in the evaluation of EF in patients with suspected CAD. Ninety-one consecutive patients with suspected CAD, scheduled for coronary angiography, underwent rest electrocardiographic-gated technetium-99m methoxyisobutylisonitrile SPECT (G-SPECT) with measurement of LVEF by QGS and transthoracic 3D echocardiography with off-line measurement of LVEF (Tomtec 4D LV Analysis 1.1). The diagnosis of CAD was based on coronary angiography, performed on every patient. Nine patients were excluded from the analysis owing to unsuitability for 3D echocardiography (8 patients) or G-SPECT (1 patient). In the remaining group of 82 patients, 71 (87%) had significant CAD, 34 (42%) had a history of myocardial infarction, and 50 (61%) had perfusion defects at rest G-SPECT images. The mean LVEF measured by QGS and 3D echocardiography was 53±13% and 53±10%, respectively. The mean difference in LVEF between 3D echocardiography and QGS was 0.1±6.0% (P=0.87), and the correlation between the values obtained by both methods was high (r=0.88, P< 0.001). The largest discrepancies were observed in patients with small ventricular volumes. In patients undergoing diagnostic work-up for CAD, the measurement of LVEF by QGS algorithm provides high correlation and satisfactory agreement with the results of reference ultrasound method- 3D echocardiography. (author)

  11. Teaching focused echocardiography for rheumatic heart disease screening

    Directory of Open Access Journals (Sweden)

    Daniel Engelman

    2015-01-01

    Full Text Available Screening for rheumatic heart disease (RHD requires workers skilled in echocardiography, which typically involves prolonged, specialized training. Task shifting echocardiographic screening to nonexpert health workers may be a solution in settings with limited human resources. An 8-week training program was designed to train health workers without any prior experience in focused echocardiography for RHD screening. Seven health workers participated. At the completion of training, the health workers performed unsupervised echocardiography on 16 volunteer children with known RHD status. A pediatric cardiologist assessed image quality. Participants provided qualitative feedback. The quality of echocardiograms were high at completion of training (55 of 56 were adequate for diagnosis and all cases of RHD were identified. Feedback was strongly positive. Training health workers to perform focused echocardiography for RHD screening is feasible. After systematic testing for accuracy, this training program could be adapted in other settings seeking to expand echocardiographic capabilities.

  12. Teaching focused echocardiography for rheumatic heart disease screening

    International Nuclear Information System (INIS)

    Engelman, Daniel; Kado, Joseph H; Reményi, Bo; Colquhoun, Samantha M; Watson, Caroline; Rayasidamu, Sera C; Steer, Andrew C

    2005-01-01

    Screening for rheumatic heart disease (RHD) requires workers skilled in echocardiography, which typically involves prolonged, specialized training. Task shifting echocardiographic screening to nonexpert health workers may be a solution in settings with limited human resources. An 8-week training program was designed to train health workers without any prior experience in focused echocardiography for RHD screening. Seven health workers participated. At the completion of training, the health workers performed unsupervised echocardiography on 16 volunteer children with known RHD status. A pediatric cardiologist assessed image quality. Participants provided qualitative feedback. The quality of echocardiograms were high at completion of training (55 of 56 were adequate for diagnosis) and all cases of RHD were identified. Feedback was strongly positive. Training health workers to perform focused echocardiography for RHD screening is feasible. After systematic testing for accuracy, this training program could be adapted in other settings seeking to expand echocardiographic capabilities

  13. Sixty-four-slice multidetector computed tomography for preoperative evaluation of left ventricular function and mass in patients with mitral regurgitation: comparison with magnetic resonance imaging and echocardiography

    International Nuclear Information System (INIS)

    Guo, Ying-kun; Yang, Zhi-gang; Ning, Gang; Rao, Li; Pen, Ying; Wu, Yang; Dong, Li; Zhang, Tai-ming; Zhang, Xiao-chun; Wang, Qi-ling

    2009-01-01

    Quantitative values of left ventricular (LV) function and muscle mass in patients with mitral regurgitation are independent predictors of cardiac morbidity and mortality. The aim of this study was to prospectively evaluate whether 64-MDCT can assess the LV function in patients with mitral regurgitation with high accuracy when compared with the MRI and echocardiography results. Fifty-one patients with mitral regurgitation underwent retrospectively ECG-gated 64-MDCT, echocardiography, and MRI for assessing the global ventricular function. End-diastolic and end-systolic volume, stroke volume, ejection fraction, and mass were measured on 64-MDCT and echocardiography, and compared with the results measured on MRI which served as the reference standard. Intertechnique agreement was tested by using Pearson's correlation and Bland-Altman analyses. No significant differences were revealed in calculated LV function and mass between the 64-MDCT and MRI (paired t test, p = 0.07-0.53). Pearson's correlation analysis showed the functional parameters and mass correlated closely between the 64-MDCT and MRI (r = 0.89-0.96, p < 0.001). When compared with MRI, echocardiography underestimated the volumetric parameters of LV (paired t test, p = 0.0003-0.004), but significantly overestimated the EF values (p = 0.003), and moderate correlations of functional parameters were obtained (r = 0.78, 0.60, 0.81, and 0.62, respectively). ECG-gated 64-MDCT allows for accurate and reliable assessment of LV function in patients with mitral regurgitation, whereas LV volumes measured by two-dimensional echocardiography were underestimated and the ejection fraction was overestimated when compared with those achieved by using MRI. (orig.)

  14. Comparison of Gated SPECT Myocardial Perfusion Imaging with Echocardiography for the Measurement of Left Ventricular Volumes and Ejection Fraction in Patients With Severe Heart Failure

    Science.gov (United States)

    Shojaeifard, Maryam; Ghaedian, Tahereh; Yaghoobi, Nahid; Malek, Hadi; Firoozabadi, Hasan; Bitarafan-Rajabi, Ahmad; Haghjoo, Majid; Amin, Ahmad; Azizian, Nasrin; Rastgou, Feridoon

    2015-01-01

    Background: Gated single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is known as a feasible tool for the measurement of left ventricular ejection fraction (EF) and volumes, which are of great importance in the management and follow-up of patients with coronary artery diseases. However, considering the technical shortcomings of SPECT in the presence of perfusion defect, the accuracy of this method in heart failure patients is still controversial. Objectives: The aim of the present study was to compare the results from gated SPECT MPI with those from echocardiography in heart failure patients to compare echocardiographically-derived left ventricular dimension and function data to those from gated SPECT MPI in heart failure patients. Patients and Methods: Forty-one patients with severely reduced left ventricular systolic function (EF ≤ 35%) who were referred for gated SPECT MPI were prospectively enrolled. Quantification of EF, end-diastolic volume (EDV), and end-systolic volume (ESV) was performed by using quantitative gated spect (QGS) (QGS, version 0.4, May 2009) and emory cardiac toolbox (ECTb) (ECTb, revision 1.0, copyright 2007) software packages. EF, EDV, and ESV were also measured with two-dimensional echocardiography within 3 days after MPI. Results: A good correlation was found between echocardiographically-derived EF, EDV, and ESV and the values derived using QGS (r = 0.67, r = 0.78, and r = 0.80 for EF, EDV, and ESV, respectively; P echocardiography. ECTb-derived EDV was also significantly higher than the EDV measured with echocardiography and QGS. The highest correlation between echocardiography and gated SPECT MPI was found for mean values of ESV different. Conclusions: Gated SPECT MPI has a good correlation with echocardiography for the measurement of left ventricular EF, EDV, and ESV in patients with severe heart failure. However, the absolute values of these functional parameters from echocardiography and gated

  15. Detection of congenital heart disease by fetal echocardiography

    International Nuclear Information System (INIS)

    Fayyaz, A.; Majeed, S.M.I.

    2013-01-01

    Objective: The objective of the study was to determine the sensitivity, specificity, accuracy and predictive value of fetal echocardiography in our set up using postnatal echocardiography as gold standard. Study Design: Validation study. Place and Duration of study: This is an ongoing study in the Radiology department of CMH Rawalpindi and Armed Forces Institute of Cardiology (AFIC) Rawalpindi and the data collected from January 2007 to Jan 2012 is presented. Patients and Methods: Two hundred eighty seven patients reported for fetal echocardiography. Two hundred twenty nine patients were subsequently included in the study. These included patients of all ages who reported to the Radiology department of CMH Rawalpindi for fetal echocardiography. Fetal echo was done on Toshiba Aplio with 3.5 MHz probe having Doppler facility. Post natal evaluation was done by a pediatric cardiologist. Results: There were 207 (90.4%) true negative cases, 15 (6.6%) true positive, 2 (0.9%) false positive and 6 (2.2%) false negative cases. The sensitivity, specificity, positive and negative predictive values were 75%, 99%, 88%, 97% respectively. Conclusion: Fetal echocardiography has high specificity, negative predictive values and accuracy and cases diagnosed as normal can reassure the parents about the normal cardiac status of the fetus. (author)

  16. Dobutamine stress echocardiography: a review and update

    Directory of Open Access Journals (Sweden)

    Gilstrap LG

    2014-04-01

    Full Text Available Lauren Gray Gilstrap,1 R Sacha Bhatia,2 Rory B Weiner,3 David M Dudzinski3 1Division of Cardiology, Brigham and Women's Hospital, Boston, MA, USA; 2Institute for Health Systems Solutions, Women's College Hospital, Toronto, ON, Canada; 3Cardiology Division, Massachusetts General Hospital, Boston, MA, USA Abstract: Stress echocardiography is a noninvasive cardiovascular diagnostic test that provides functional and hemodynamic information in the assessment of a number of cardiac diseases. Performing stress echocardiography with a pharmacologic agent such as dobutamine allows for simulation of increased heart rate and increased myocardial physiologic demands in patients who may be unable to exercise due to musculoskeletal or pulmonary comorbidities. Dobutamine stress echocardiography (DSE, like exercise echocardiography, has found its primary application in ischemic heart disease, with roles in identification of obstructive epicardial coronary artery disease, detection of viable myocardium, and assessment of the efficacy of anti-ischemic medical therapy in patients with known coronary artery disease. DSE features prominently in the evaluation and management of valvular heart disease by helping to assess the effects of mitral and aortic stenoses, as well as a specific use in differentiating true severe valvular aortic stenosis from pseudostenosis that may occur in the setting of left ventricular systolic dysfunction. DSE is generally well tolerated, and its side effects and contraindications generally relate to consequences of excess inotropic and/or chronotropic stimulation of the heart. The aim of this paper is to review the indications, contraindications, advantages, disadvantages, and risks of DSE. Keywords: stress echocardiography, dobutamine, coronary artery disease, myocardial ischemia

  17. Technetium-99m sestamibi myocardial tomography based on dipyridamole echocardiography testing in hypertensive patients with chest pain

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, O. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Moroni, C. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Scopinaro, F. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Tavolaro, R. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Danieli, R. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy); Bossini, A. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Cassone, R. [Department of Internal Medicine, University ``La Sapienza``, Rome (Italy); Colella, A.C. [Section of Nuclear Medicine, Department of Experimental Medicine and Pathology, University ``La Sapienza``, Rome (Italy)

    1997-07-01

    The aim of this study was to evaluate the diagnostic capability of technetium-99m sestamibi tomography based on dipyridamole echocardiography testing in hypertensives with chest pain, and to compare the scintigraphic results with those of coronary angiography, exercise electrocardiography and dipyridamole echocardiography. Forty subjects with mild to moderate hypertension, chest pain and no previous myocardial infarction were submitted to {sup 99m}Tc-sestamibi tomography (at rest and after high-dose dipyridamole echocardiography) and to exercise electrocardiography testing. At coronary angiography 22 patients (group A) had significant epicardial coronary artery disease ({>=}70% stenosis of at least one major vessel) and 18 normal main coronary vessels (group B). Dipyridamole {sup 99m}Tc-sestamibi imaging was positive in 21/22 patients of group A and in 5/18 of group B. Dipyridamole echocardiography was positive in 18/22 patients of group A and in 5/18 of group B. Exercise electrocardiography was positive in 15/22 patients of group A and in 11/18 of group B. Four out of five subjects in group B with positive results in all the tests showed a slow run-off of angiographic contrast medium, probably due to small-vessel disease. Significant epicardial coronary artery disease in hypertensives with chest pain is unlikely when dipyridamole {sup 99m}Tc-sestamibi tomography is negative. When scintigraphy is positive, either epicardial coronary artery disease or a small-vessel disease condition is possible. The association of scintigraphy with dipyridamole echocardiography testing allows the assessment of contractile function and myocardial perfusion by a single pharmacological stress. (orig./AJ). With 3 figs., 2 tabs.

  18. Coronary flow velocity reserve by echocardiography

    DEFF Research Database (Denmark)

    Olsen, Rasmus Huan; Pedersen, Lene Rørholm; Snoer, Martin

    2016-01-01

    BACKGROUND: Coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography of the LAD is used to assess microvascular function but validation studies in clinical settings are lacking. We aimed to assess feasibility, reproducibility and agreement with myocardial flow...... performed within a week (1-week) and for all scans regardless of time gap (total) and to account for scar tissue for patients with and without previous myocardial infarction (MI). RESULTS: Eighty-six patients with median BMI 30.9 (IQR 29.4-32.9) kg × m(-2) and CFVR 2.29 (1.90-2.63) were included. CFVR...... was feasible in 83 (97 %) using a contrast agent in 14 %. For reproducibility overall (n = 21) limits of agreement (LOA) were (-0.75;0.71), within-subjects coefficient of variation (CV) 11 %, and reliability 0.84. For reproducibility within 1-week (n = 13) LOA were (-0.33;0.25), within-subjects CV 5...

  19. Acute anterior myocardial infarction seen on conventional iodine-contrast CT

    Directory of Open Access Journals (Sweden)

    Christian Hagdrup, MD

    2017-09-01

    Full Text Available Diagnosis of acute myocardial infarction (AMI is based on clinical symptoms of chest pain and dyspnea in combination with electrocardiographic changes and a raise in myocardial-specific biomarkers. Imaging is by echocardiography and magnetic resonance. The preferred technique for identification of previous myocardial infarction (MI is magnetic resonance imaging with late gadolinium technique, but in the acute patient echocardiography is applied. In selected cases, important information can be obtained from other imaging modalities. We describe a case of a patient first suspected of an abdominal catastrophe in whom acute MI was diagnosed from a computerized tomography (CT scan with iodine contrast. Our case together with a few other cases reported in the literature demonstrate that contrast enhancement of the myocardium can be important to follow in the acute patient because the CT scans sometimes give a unique opportunity to recognize findings consistent with MI even though the CT scan was performed for another reason.

  20. The effect of filtrating and reconstruction method on the left ventricular ejection fraction derived from GSPET. A statistical comparison of angiography and echocardiography

    International Nuclear Information System (INIS)

    Bitarafan, A.; Rajabi, H.

    2008-01-01

    There are different protocols of reconstruction in myocardial gated imaging that produce different values of left ventricular ejection fraction (EF). We attempted to determine how the parameters of reconstruction affect the calculated EF. The results were statistically compared with the values obtained from angiography and echocardiography. In this retrospective study, the data from 23 patients were used. All the patients had the angiographic and the echocardiographic data within 2 weeks before the test. Imaging was performed using a single-head gamma camera using technetium-99 methoxyisobutylisonitrile. The image data were reconstructed using 50 different combinations of the ramp, Hanning, Butterworth, Wiener, and Metz filters. The ordered subset expectation maximization (OSEM) technique was also examined using 12 combinations of iteration and subset. The calculated EF values were analyzed and compared with the echocardiographic and angiographic results. The backprojection technique produced higher values of EF than those derived from echocardiography and angiography. The OSEM on the other hand produced lower values when compared with echocardiography and angiography. On using the backprojection technique, the maximum correlation between the values derived from gated single-photon emission tomography and echocardiography (r=0.88, P<0.01) and angiography (r=0.81, P<0.01) was observed when using the Metz filter (full width at half maximum=5 mm and order=9) and the Gaussian filter (α=3), respectively. In the case of the OSEM technique, the maximum correlation with both angiography and echocardiography was observed when using the iteration=2 and the subset=12. On the average, the backprojection technique produces higher values, and iteration technique produces lower estimation of the EF when compared with angiography and echocardiography. (author)

  1. Use of echocardiography at diagnosis and detection of acute cardiac disease in youth with systemic lupus erythematosus.

    Science.gov (United States)

    Chang, J C; Knight, A M; Xiao, R; Mercer-Rosa, L M; Weiss, P F

    2018-01-01

    Objectives There are no guidelines on the use of echocardiography to detect cardiac manifestations of childhood-onset systemic lupus erythematosus (SLE). We quantify the prevalence of acute cardiac disease in youth with SLE, describe echocardiogram utilization at SLE diagnosis, and compare regional echocardiogram use with incident cardiac diagnoses. Methods Using the Clinformatics® DataMart (OptumInsight, Eden Prairie, MN) de-identified United States administrative database from 2000 to 2013, we identified youth ages 5-24 years with new-onset SLE (≥3 ICD-9 SLE codes 710.0, > 30 days apart) and determined the prevalence of diagnostic codes for pericardial disease, myocarditis, endocarditis, and valvular insufficiency. Multiple logistic regression was used to identify factors associated with echocardiography during the baseline period, up to one year before or six months after SLE diagnosis. We calculated a regional echocardiogram utilization index, which is the ratio of observed use over the mean predicted probability based on all available baseline characteristics. Spearman's rank correlation coefficient was used to evaluate the association between regional echocardiogram utilization indices and percentage of imaged youth diagnosed with their first cardiac manifestation following echocardiography. Results Among 699 youth with new-onset SLE, 18% had ≥ 1 diagnosis code for acute cardiac disease, of which valvular insufficiency and pericarditis were most common. Twenty-five percent of all youth underwent echocardiogram during the baseline period. Regional echocardiogram use was positively correlated with the percentage of imaged youth found to have cardiac disease (ρ = 0.71, p = 0.05). There was up to a five-fold difference in adjusted odds of baseline echocardiography between low- and high-utilizing regions (OR = 0.19, p = 0.007). Conclusion Nearly one-fifth of youth with new-onset SLE have acute cardiac manifestations; however, use of

  2. Left Ventricular Myocardial Deformation Parameters Are Affected by Coronary Slow Flow Phenomenon: A Study of Speckle Tracking Echocardiography.

    Science.gov (United States)

    Gulel, Okan; Akcay, Murat; Soylu, Korhan; Aksan, Gokhan; Yuksel, Serkan; Zengin, Halit; Meric, Murat; Sahin, Mahmut

    2016-05-01

    The coronary slow flow phenomenon (CSFP) is defined as a delayed distal vessel contrast opacification in the absence of obstructive epicardial coronary artery disease during coronary angiography. There is conflicting data in medical literature regarding the effects of CSFP on the left ventricular functions assessed by conventional echocardiography or tissue Doppler imaging. Therefore, we aimed to evaluate whether there is any abnormality in the myocardial deformation parameters (strain, strain rate (SR), rotation, twist) of the left ventricle obtained by speckle tracking echocardiography (STE) in patients with CSFP. Twenty patients with CSFP were included prospectively in the study. Another 20 patients with similar demographics and cardiovascular risk factors as well as normal coronary angiography were used as the control group. Two-dimensional echocardiographic images of the left ventricle from the apical long-axis, two-chamber, four-chamber, and parasternal short-axis views were used for STE analysis. The analysis of left ventricular circumferential deformation parameters showed that the averaged peak systolic strain, systolic SR, and early diastolic SR values were significantly lower in patients with CSFP (P = 0.009, P = 0.02, and P = 0.02, respectively). Among the left ventricular rotation and twist values, apical rotation was significantly lower in patients with CSFP (P = 0.02). Further, the mean thrombolysis in myocardial infarction frame count value was found to be negatively correlated with the averaged peak circumferential early diastolic SR (r = -0.35, P = 0.03). It was positively correlated with the averaged peak circumferential systolic strain (r = 0.47, P = 0.003) and circumferential systolic SR (r = 0.46, P = 0.005). Coronary slow flow phenomenon leads to significant alterations in the myocardial deformation parameters of the left ventricle as assessed by STE. Specifically, circumferential deformation parameters are affected in CSFP patients. © 2015

  3. Echocardiography in the flight program

    Science.gov (United States)

    Charles, John B.; Bungo, Michael W.; Mulvagh, Sharon L.

    1991-01-01

    Observations on American and Soviet astronauts have documented the association of changes in cardiovascular function during orthostasis with space flight. A basic understanding of the cardiovascular changes occurring in astronauts requires the determination of cardiac output and total peripheral vascular resistance as a minimum. In 1982, we selected ultrasound echocardiography as our means of acquiring this information. Ultrasound offers a quick, non-invasive and accurate means of determining stroke volume which, when combined with the blood pressure and heart rate measurements of the stand test, allows calculation of changes in peripheral vascular resistance, the body's major response to orthostatic stress. The history of echocardiography in the Space Shuttle Program is discussed and the results are briefly presented.

  4. 3D Harmonic Echocardiography:

    NARCIS (Netherlands)

    M.M. Voormolen (Marco)

    2007-01-01

    textabstractThree dimensional (3D) echocardiography has recently developed from an experimental technique in the ’90 towards an imaging modality for the daily clinical practice. This dissertation describes the considerations, implementation, validation and clinical application of a unique

  5. Echocardiography in Infective Endocarditis: State of the Art.

    Science.gov (United States)

    Afonso, Luis; Kottam, Anupama; Reddy, Vivek; Penumetcha, Anirudh

    2017-10-25

    In this review, we examine the central role of echocardiography in the diagnosis, prognosis, and management of infective endocarditis (IE). 2D transthoracic echocardiography (TTE) and transesophageal echocardiography TEE have complementary roles and are unequivocally the mainstay of diagnostic imaging in IE. The advent of 3D and multiplanar imaging have greatly enhanced the ability of the imager to evaluate cardiac structure and function. Technologic advances in 3D imaging allow for the reconstruction of realistic anatomic images that in turn have positively impacted IE-related surgical planning and intervention. CT and metabolic imaging appear to be emerging as promising ancillary diagnostic tools that could be deployed in select scenarios to circumvent some of the limitations of echocardiography. Our review summarizes the indispensable and central role of various echocardiographic modalities in the management of infective endocarditis. The complementary role of 2D TTE and TEE are discussed and areas where 3D TEE offers incremental value highlighted. An algorithm summarizing a contemporary approach to the workup of endocarditis is provided and major societal guidelines for timing of surgery are reviewed.

  6. Evaluation of left ventricular function and volumes in patients with ischaemic cardiomyopathy: gated single-photon emission computed tomography versus two-dimensional echocardiography

    International Nuclear Information System (INIS)

    Vourvouri, E.C.; Poldermans, D.; Sianos, G.; Sozzi, F.B.; Schinkel, A.F.L.; Sutter, J. de; Roelandt, J.R.T.C.; Bax, J.J.; Parcharidis, G.; Valkema, R.

    2001-01-01

    The objective of this study was to perform a head-to-head comparison between two-dimensional (2D) echocardiography and gated single-photon emission computed tomography (SPET) for the evaluation of left ventricular (LV) function and volumes in patients with severe ischaemic LV dysfunction. Thirty-two patients with chronic ischaemic LV dysfunction [mean LV ejection fraction (EF) 25%±6%] were studied with gated SPET and 2D echocardiography. Regional wall motion was evaluated by both modalities and scored by two independent observers using a 16-segment model with a 5-point scoring system (1= normokinesia, 2= mild hypokinesia, 3= severe hypokinesia, 4= akinesia and 5= dyskinesia). LVEF and LV end-diastolic and end-systolic volumes were evaluated by 2D echocardiography using the Simpson's biplane discs method. The same parameters were calculated using quantitative gated SPET software (QGS, Cedars-Sinai Medical Center). The overall agreement between the two imaging modalities for assessment of regional wall motion was 69%. The correlations between gated SPET and 2D echocardiography for the assessment of end-diastolic and end-systolic volumes were excellent (r=0.94, P<0.01, and r=0.96, P<0.01, respectively). The correlation for LVEF was also good (r=0.83, P<0.01). In conclusion: in patients with ischaemic cardiomyopathy, close and significant relations between gated SPET and 2D echocardiography were observed for the assessment of regional and global LV function and LV volumes; gated SPET has the advantage that it provides information on both LV function/dimensions and perfusion. (orig.)

  7. Transesophageal echocardiography for cardiac thromboembolic risk assessment in patients with severe, symptomatic aortic valve stenosis referred for potential transcatheter aortic valve implantation.

    Science.gov (United States)

    Lenders, Guy D; Paelinck, Bernard P; Wouters, Kristien; Claeys, Marc J; Rodrigus, Inez E; Van Herck, Paul L; Vrints, Christiaan J; Bosmans, Johan M

    2013-05-15

    Stroke is a devastating complication after transcatheter aortic valve implantation (TAVI) and might partially be related to cardiac embolization. The aim of this single-center prospective study was to determine the incidence of intracardiac thrombi and left atrial spontaneous echo contrast (SEC), both known predictors of cardiac embolic stroke, in patients referred for potential TAVI. One hundred four consecutive patients with severe symptomatic aortic valve stenosis and at high or very high risk for surgery were included and underwent transesophageal echocardiography. In 11 patients (10.6%), intracardiac thrombi were detected, and 25 patients (24%) showed dense grade 2 SEC. Atrial fibrillation (p risk patients with severe aortic valve stenosis referred for potential TAVI is high and can accurately be detected using transesophageal echocardiography. Systematic thromboembolic evaluation using transesophageal echocardiography is thus recommended in patients referred for TAVI. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Dobutamine Stress Echocardiography and Tissue Synchronization Imaging

    Science.gov (United States)

    Tas, Hakan; Gundogdu, Fuat; Gurlertop, Yekta; Karakelleoglu, Sule

    2008-01-01

    Dobutamine stress echocardiography has emerged as a reliable method for the diagnosis of coronary artery disease and the management of its treatment. Several studies have shown that that this technique works with 80–85% accuracy in comparison with other imaging methods. There are few studies aimed at developing the clinical utility of dobutamine stress echocardiography for the evaluation of normal and abnormal segments that result from dobutamine stress with Tissue Synchronization Imaging. PMID:25610034

  9. Transcatheter aortic-valve implantation with one single minimal contrast media injection.

    Science.gov (United States)

    Arrigo, Mattia; Maisano, Francesco; Haueis, Sabine; Binder, Ronald K; Taramasso, Maurizio; Nietlispach, Fabian

    2015-06-01

    Performing transcatheter aortic valve implantation (TAVI) with the use of minimal contrast in patients at high-risk for acute kidney injury (AKI). Contrast-induced nephropathy (CIN) is a major cause of AKI following TAVI and is associated with increased morbidity and mortality. The amount of contrast media used increases the risk for CIN. Computed tomography was omitted during the screening process. For the procedure transfemoral access was default. The self-expanding CoreValve prosthesis was chosen in all patients to minimize the risk of annular rupture in case of oversizing. Valve sizing was based on echocardiography, aortography, calcification on fluoroscopy, as well as weight and height of the patient. A single contrast injection was performed to confirm correct position of the pigtail catheter at the level of the annulus. The pigtail then served as the marker for the device landing zone. Intraprocedural assessment of the implantation result relied on echocardiography and hemodynamics. Five patients with severe aortic stenosis and at high risk for developing CIN were included. Device success was achieved in all patients and no major complications occurred. The median dose of injected contrast media was 8 ml (4-9). All but one patient had improved renal function after the intervention compared to baseline. Our study shows feasibility of performing TAVI with a single minimal contrast media injection, using a self-expandable valve. This technique has the potential to reduce the incidence of CIN. © 2015 Wiley Periodicals, Inc.

  10. Multi-view 3D echocardiography compounding based on feature consistency

    Science.gov (United States)

    Yao, Cheng; Simpson, John M.; Schaeffter, Tobias; Penney, Graeme P.

    2011-09-01

    Echocardiography (echo) is a widely available method to obtain images of the heart; however, echo can suffer due to the presence of artefacts, high noise and a restricted field of view. One method to overcome these limitations is to use multiple images, using the 'best' parts from each image to produce a higher quality 'compounded' image. This paper describes our compounding algorithm which specifically aims to reduce the effect of echo artefacts as well as improving the signal-to-noise ratio, contrast and extending the field of view. Our method weights image information based on a local feature coherence/consistency between all the overlapping images. Validation has been carried out using phantom, volunteer and patient datasets consisting of up to ten multi-view 3D images. Multiple sets of phantom images were acquired, some directly from the phantom surface, and others by imaging through hard and soft tissue mimicking material to degrade the image quality. Our compounding method is compared to the original, uncompounded echocardiography images, and to two basic statistical compounding methods (mean and maximum). Results show that our method is able to take a set of ten images, degraded by soft and hard tissue artefacts, and produce a compounded image of equivalent quality to images acquired directly from the phantom. Our method on phantom, volunteer and patient data achieves almost the same signal-to-noise improvement as the mean method, while simultaneously almost achieving the same contrast improvement as the maximum method. We show a statistically significant improvement in image quality by using an increased number of images (ten compared to five), and visual inspection studies by three clinicians showed very strong preference for our compounded volumes in terms of overall high image quality, large field of view, high endocardial border definition and low cavity noise.

  11. Multi-view 3D echocardiography compounding based on feature consistency

    International Nuclear Information System (INIS)

    Yao Cheng; Schaeffter, Tobias; Penney, Graeme P; Simpson, John M

    2011-01-01

    Echocardiography (echo) is a widely available method to obtain images of the heart; however, echo can suffer due to the presence of artefacts, high noise and a restricted field of view. One method to overcome these limitations is to use multiple images, using the 'best' parts from each image to produce a higher quality 'compounded' image. This paper describes our compounding algorithm which specifically aims to reduce the effect of echo artefacts as well as improving the signal-to-noise ratio, contrast and extending the field of view. Our method weights image information based on a local feature coherence/consistency between all the overlapping images. Validation has been carried out using phantom, volunteer and patient datasets consisting of up to ten multi-view 3D images. Multiple sets of phantom images were acquired, some directly from the phantom surface, and others by imaging through hard and soft tissue mimicking material to degrade the image quality. Our compounding method is compared to the original, uncompounded echocardiography images, and to two basic statistical compounding methods (mean and maximum). Results show that our method is able to take a set of ten images, degraded by soft and hard tissue artefacts, and produce a compounded image of equivalent quality to images acquired directly from the phantom. Our method on phantom, volunteer and patient data achieves almost the same signal-to-noise improvement as the mean method, while simultaneously almost achieving the same contrast improvement as the maximum method. We show a statistically significant improvement in image quality by using an increased number of images (ten compared to five), and visual inspection studies by three clinicians showed very strong preference for our compounded volumes in terms of overall high image quality, large field of view, high endocardial border definition and low cavity noise.

  12. Correlation between image quality of CT scan and amount of intravenous contrast media

    International Nuclear Information System (INIS)

    Yoon, Dae Young; Choi, Dae Seob; Kim, Seung Hyup; Han, Joon Koo; Choi, Byung Ihn; Im, Jung Gi; Han, Moon Hee; Chang, Kee Hyun; Kim, Jong Hyo; Han, Man Chung

    1993-01-01

    A blind, comparative clinical study was performed prospectively to examine the correlation between image quality of CT scan in terms of contrast enhancement effect and amount of intravenous contrast media. A total of 357 patients were randomized into two groups. Ionic high-osmolality contrast media (68% meglumine ioglicate) was administered intravenously as 100 ml bolus in one group and as 50 ml bolus in the other group. Statistically significant differences of image quality were found in CT scans of the brain, head and neck, chest and abdomen (p 0.05). We suggest that amount of contrast media may be reduced in pelvis CT without significant degradation of image quality

  13. The Role of Focused Echocardiography in Pediatric Intensive Care: A Critical Appraisal

    Science.gov (United States)

    Gaspar, Heloisa Amaral; Morhy, Samira Saady

    2015-01-01

    Echocardiography is a key tool for hemodynamic assessment in Intensive Care Units (ICU). Focused echocardiography performed by nonspecialist physicians has a limited scope, and the most relevant parameters assessed by focused echocardiography in Pediatric ICU are left ventricular systolic function, fluid responsiveness, cardiac tamponade and pulmonary hypertension. Proper ability building of pediatric emergency care physicians and intensivists to perform focused echocardiography is feasible and provides improved care of severely ill children and thus should be encouraged. PMID:26605333

  14. Echocardiography in Ebstein's anomaly

    NARCIS (Netherlands)

    W.J. Gussenhoven (Wilhelmina Johanna)

    1984-01-01

    textabstractIn this thesis the value of echocardiography is evaluated for the diagnosis of Ebstein's anomaly of the tricuspid valve. This congenital heart defect, first described in 1866 by Wilhelm Ebstein, is characterized by an apical displacement of the septal and inferior tricuspid valve

  15. Bladder transitional cell carcinoma: correlation of contrast enhancement on computed tomography with histological grade and tumour angiogenesis

    International Nuclear Information System (INIS)

    Xie, Q.; Zhang, J.; Wu, P.-H.; Jiang, X.-Q.; Chen, S.-L.; Wang, Q.-L.; Xu, J.; Chen, G.-D.; Deng, J.-H.

    2005-01-01

    AIM: To investigate the correlation between the degree of contrast enhancement of bladder cancer in the early enhanced phase of helical computed tomography (CT) and microvessel density (MVD), vascular endothelial growth factor (VEGF) and histological grade. MATERIALS AND METHODS: Sixty-five patients with transitional cell carcinoma of the bladder were examined by incremental unenhanced CT and helical CT at 40-45 s after initiation of intravenous administration of contrast medium before surgery. The CT density in Hounsfield units of bladder carcinomas were measured in the middle of the maximum diameter section of the cancer lesions on unenhanced and enhanced CT. The degree of contrast enhancement of the tumour was determined as the absolute increase in Hounsfield units. Histological grade, VEGF and MVD were analysed for each cancer. The Pearson and Spearman correlation tests were used to determine the strength of the relationships between CT enhancement and histological grade, VEGF expression and MVD. RESULTS: Different degrees of enhancement were observed in 91 cancers during the early enhanced phase of helical CT. Mean MVDs and mean CT enhancing values of different histological grade groups were statistically different (p<0.001). A positive correlation was found in the CT-enhancing value of bladder cancer and MVD (Pearson correlation test; r=0.938, p<0.001) and histological grade (Spearman rank correlation; r=0.734, p<0.001). VEGF of bladder cancer did not correlate with the change in CT attenuation (Spearman rank correlation; r=0.087, p=0.410) and MVD (Spearman rank correlation, r=0.103, p=0.330). CONCLUSION: In bladder cancer, the degree of contrast enhancement during the early enhanced helical CT is correlated with the MVD and histological grade of tumour. It is possible that MVD is the histopathological basis of early contrast enhancement of bladder cancer

  16. V–V delay interval optimization in CRT using echocardiography compared to QRS width in surface ECG

    Directory of Open Access Journals (Sweden)

    Amr Nawar

    2012-09-01

    Conclusion: Significant correlation appeared to exist during optimization of CRT between VV programming based on the shortest QRS interval at 12-lead ECG pacing and that based on highest LVOT VTI by echocardiography. A combined ECG and echocardiographic approach could be a more convenient solution in performing V–V optimization.

  17. Usefulness and limitations of transthoracic echocardiography in heart transplantation recipients

    Directory of Open Access Journals (Sweden)

    Galderisi Maurizio

    2008-01-01

    Full Text Available Abstract Transthoracic echocardiography is a primary non-invasive modality for investigation of heart transplant recipients. It is a versatile tool which provides comprehensive information about cardiac structure and function. Echocardiographic examinations can be easily performed at the bedside and serially repeated without any patient's discomfort. This review highlights the usefulness of Doppler echocardiography in the assessment of left ventricular and right ventricular systolic and diastolic function, of left ventricular mass, valvular heart disease, pulmonary arterial hypertension and pericardial effusion in heart transplant recipients. The main experiences performed by either standard Doppler echocardiography and new high-tech ultrasound technologies are summarised, pointing out advantages and limitations of the described techniques in diagnosing acute allograft rejection and cardiac graft vasculopathy. Despite the sustained efforts of echocardiographic technique in predicting the biopsy state, endocardial myocardial biopsies are still regarded as the gold standard for detection of acute allograft rejection. Conversely, stress echocardiography is able to identify accurately cardiac graft vasculopathy and has a recognised prognostic in this clinical setting. A normal stress-echo justifies postponement of invasive studies. Another use of transthoracic echocardiography is the monitorisation and the visualisation of the catheter during the performance of endomyocardial biopsy. Bedside stress echocardiography is even useful to select appropriately heart donors with brain death. The ultrasound monitoring is simple and effective for monitoring a safe performance of biopsy procedures.

  18. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 month...

  19. Role of echocardiography in the evaluation of syncope: a prospective study

    Science.gov (United States)

    Sarasin, F P; Junod, A-F; Carballo, D; Slama, S; Unger, P-F; Louis-Simonet, M

    2002-01-01

    Objective: To study the role of echocardiography in the stepwise evaluation of syncope. Design: A prospective observational study with an 18 month follow up. Setting: University teaching hospital providing primary and tertiary care. Subjects: 650 consecutive patients with syncope and clinical suspicion of an obstructive valvar lesion, or with syncope not explained by history, physical examination, or a 12 lead ECG, who underwent bidimensional Doppler transthoracic echocardiography. Main outcome measures: The causes of syncope were assigned using published diagnostic criteria. Echocardiography was considered diagnostic when confirming a suspected diagnosis, or when revealing occult cardiac disease explaining the syncope. Results: A systolic murmur was identified in 61 of the 650 patients (9%). Severe aortic stenosis was suspected in 20 of these and was confirmed by echocardiography in eight. Follow up excluded further cases of aortic stenosis. In patients with unexplained syncope (n = 155), routine echocardiography showed no abnormalities that established the cause of the syncope. Echocardiography was normal or non-relevant in all patients with a negative cardiac history and a normal ECG (n = 67). In patients with a positive cardiac history or an abnormal ECG (n = 88), echocardiography showed systolic dysfunction (left ventricular ejection fraction ≤ 40%) in 24 (27%) and minor non-relevant findings in the remaining 64. Arrhythmias were diagnosed in 12 of the 24 patients with systolic dysfunction (50%), and in 12 of the 64 remaining patients (19%) (p < 0.01). Conclusions: Echocardiography was most useful for assessing the severity of the underlying cardiac disease and for risk stratification in patients with unexplained syncope but with a positive cardiac history or an abnormal ECG. PMID:12231593

  20. Imaging the heart: cardiac scintigraphy and echocardiography in US hospitals (1983)

    International Nuclear Information System (INIS)

    McPhee, S.J.; Garnick, D.W.

    1986-01-01

    The rapid growth of cardiac catheterization has raised questions about the availability of less costly, noninvasive tests such as cardiac scintigraphy and echocardiography. To assess their availability and rates of use, we surveyed 3778 non-federal short-term US hospitals in June, 1983. Overall, 2605 hospitals (69%) offered 201 Tl myocardial perfusion scans, 2580 (68%) 99mTc equilibrium gated blood pool scans, and 2483 (67%) cardiac shunt scans; 1679 hospitals (44%) offered M-mode and/or 2-dimensional echocardiography, and 768 (20%) pulsed Doppler echocardiography. Volumes of procedures varied enormously among hospitals capable of performing them. High volumes of both scintigraphy and echocardiography were performed in a small number of hospitals. Larger, voluntary, and teaching hospitals performed higher volumes of both procedures. Despite widespread availability of these noninvasive technologies, high volumes of both cardiac scintigraphy and echocardiography procedures are concentrated in a small number of US hospitals

  1. A case of complete double aortic arch visualized by transthoracic echocardiography.

    Science.gov (United States)

    Saito, Naka; Kato, Shingo; Saito, Noritaka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Kosuge, Masami; Kimura, Kazuo

    2017-08-01

    A case of double aortic arch that was well visualized using transthoracic echocardiography is reported. A 38-year-old man underwent transthoracic echocardiography for the evaluation of dyspnea. A suprasternal view of transthoracic echocardiography showed the ascending aorta bifurcate to left and right aortic arches, with blood flow from the ascending aorta to bilateral aortic arches. The diagnosis of right side-dominant double aortic arch was made, and the patient's symptom was conceivably related to compression of the trachea due to a vascular ring. This report indicates the potential usefulness of transthoracic echocardiography for noninvasive detection of double aortic arch in adults. © 2017, Wiley Periodicals, Inc.

  2. [Pulmonary artery pressure evaluation in adults by Doppler echocardiography].

    Science.gov (United States)

    Campos Filho, O; Andrade, J L; Carvalho, A C; Luna Filho, B; Pfeferman, A; Arroyo, J B; Leão, L E; Martinez Filho, E E

    1991-04-01

    To assess the role of pulsed Doppler echocardiography (PDE) in the indirect assessment of pulmonary artery (PA) pressure (P), analysing the pulmonary velocity blood flow curves (PVBFC) profile. Sixty-one adults with several kinds of heart disease were submitted to heart catheterization to obtain PAP (systolic, diastolic, mean), and other hemodynamic variables. A PDE examination was performed in all to obtain the PVBFC at the level of the pulmonic annulus. Qualitative features of the curve were analysed (morphological pattern, presence of pulmonic regurgitation) as well as quantitative data (acceleration time = AT, right ventricle ejection time = RVET index, AT/RVET index AT corrected for heart rate = ATC), which were compared to the invasive measurements. An abnormal rapid acceleration of the PVBFC, with triangular configuration, was noted in patient with pulmonary hypertension (PH), in contrast to the dome-like shape of the PVBFC in normal PAP. Pulmonary regurgitation was more frequent (p less than 0.05) in patients with severe PH (mean PAP greater than or equal to 40 mmHg), comparing with patients with PAP less than 40 mmHg. Inverse linear correlations were observed between AT and mean PAP, particularly when sinus rhythm was present (r = 0.89; p less than 0.05) excluding patients with atrial fibrilation (19 cases). PDE is an useful and noninvasive method for indirect evaluation of PAP in adults, especially during stable sinus rhythm, in heart rate range from 60 to 115 bpm.

  3. Targeted neonatal echocardiography services: need for standardized training and quality assurance.

    Science.gov (United States)

    Finan, Emer; Sehgal, Arvind; Khuffash, Afif El; McNamara, Patrick J

    2014-10-01

    Targeted neonatal echocardiography refers to a focused assessment of myocardial performance and hemodynamics directed by a specific clinical question. It has become the standard of care in many parts of the world, but practice is variable, and there has been a lack of standardized training and evaluation to date. Targeted neonatal echocardiography was first introduced to Canada in 2006. The purpose of this study was to examine the characteristics of targeted neonatal echocardiography practice and training methods in Canadian neonatal intensive care units (NICUs). A total of 142 Canadian neonatologists were invited to participate in an online survey, which was conducted in September 2010. The survey consisted of questions related to the availability of targeted neonatal echocardiography, clinical indications, benefits and risks, and training methods. The overall survey response rate was 65%. Forty-eight respondents (34%) indicated that targeted neonatal echocardiography was available in their units, and the program was introduced within the preceding 1 to 5 years. In centers where it was unavailable, lack of on-site echocardiography expertise was cited as the major barrier to implementation. The most common indications for targeted neonatal echocardiography included evaluation of a hemodynamically significant ductus arteriosus, systemic or pulmonary blood flow, and response to cardiovascular treatments. Only 27% of respondents, working in centers where targeted neonatal echocardiography existed, actually performed the studies themselves; most individuals completed 11 to 20 studies per month. Almost half of the respondents said that training was available in their institutions, but methods of training and evaluation were inconsistent. Eighty-seven percent of respondents reported no formalized process for assessment of ongoing competency after the initial training period. Targeted neonatal echocardiography is becoming more widely available and is gaining acceptance in

  4. Trans-pulmonary echocardiography as a guide for device closure of patent ductus arteriosus.

    Science.gov (United States)

    Kudo, Yoshiyuki; Suda, Kenji; Yoshimoto, Hironaga; Teramachi, Yozo; Kishimoto, Shintaro; Iemura, Motofumi; Matsuishi, Toyojiro

    2015-08-01

    The aim of this study was to develop trans-pulmonary echocardiography (TPE) to guide device closure of patent ductus arteriosus (DC-PDA). Aortography requires a large amount of contrast yet may give us an inadequate image to evaluate anatomy or residual shunt in patients with large PDA or dilated vessels and is precluded in patients with renal dysfunction. Practically, there is no imaging modality to monitor the entire procedure except for trans-esophageal echocardiography that requires general anesthesia. Subjects were seven patients with ages ranged from 6- to 77-years old and body weight > 15 kg. The size of the PDA ranged from 1.8 to 6.3 mm with pulmonary to systemic flow ratios from 1.2 to 2.2. During DC-PDA using Ampaltzer Duct Occluder or coil, an intra-cardiac echocardiographic (ICE) catheter was advanced into pulmonary arteries and standard views were developed to guide DC-PDA. We have developed two standard views; the main pulmonary artery view (MPA view) and the left pulmonary artery view (LPA view). The MPA view provided aortic short axis view equivalent to that seen by trans-thoracic echocardiography in children. The LPA view, obtained by the echo probe in the LPA and turned it up upside down, provided long axis view of the PDA allowing more precise anatomical evaluation. TPE allowed us to monitor the entire procedure and determine residual shunts. TPE in the MPA and LPA view can be an effective guide for DC-PDA. This report leads to new application of this imaging device. © 2015 Wiley Periodicals, Inc.

  5. Echocardiography in the adult's congenital cardiopaties

    International Nuclear Information System (INIS)

    Escobar Q, Carlos I; Jaramillo U, Mario; Tenorio, Luis F; Molina V, Claudia; Saldarriaga A, Marcela; Arango, Angela M

    2003-01-01

    The number of adults with congenital heart disease is steadily increasing in the course of time. We ignore the prevalence and the most frequent diagnoses in our environment. A descriptive prospective study is presented. Between November 1 1999 and July 31 2001, 8871 Tran-thoracic and Tran-esophageal echocardiographies were performed in the Clinica Cardiovascular Santa Maria's echocardiography service. We found 143 congenital cardiopathies (1.6%) in 74 men and 69 women with a mean age of 37.7 +/- 18.4 years. the most frequent diagnoses were bicuspid aortic valve, atrial septal defect, ventricular septal defect, patent ductus arteriosus and Ebstein's anomaly. these findings agree with world wide data

  6. Comparative study between MRI and echocardiography in noncompaction of ventricular myocardium

    International Nuclear Information System (INIS)

    Sun Ziyan; Xia Liming; Wang Chengyuan; Rao Jingjing; Shenyu Weihui

    2007-01-01

    Objective: To investigate the MRI and echocardiography manifestations of noncompaction of ventricular myocardium(NVM) and assess the role of MR1 in the diagnosis of NVM by comparing it with echocardiography. Methods: Fourteen cases of NVM diagnosed by echocardiography were examined with MRI, including scanning of black-blood sequences, double inversion recovery fast spin echo (DIBFSE) and triple inversion recovery fast spin echo (TIRFSE), and white blood sequence: fast imaging employ steady state acquisition (FIESTA). Scanning plane includes short axis view, four-chamber view and long axis view. Results: Both MRI and echocardiography displayed involvement of left ventricles in thirteen cases and involvement of double ventricles in one case. Apexes of heart and the intermedius are commonly affected. MRI showed 54 segments and echocardiography showed 53 segments affected, and there is no significant difference between the capability of MRI and echocardiography (P=1,000). The affected myocardium consisted of two layers: subendocardial noncompacted myocardium and epicardial compacted myocardium, and the ratio measurement of N/C by MRI was 3.37±0.89 and it was 3.19±0.82 by echocardiography. Noncompacted myocardium was characterized by prominent and excessive myocardial trabeculations and deep intratrabecular recesses, in which the blood flow was communicated with the ventricle. One case was complicated with ventricular aneurysm, and coronary arteriography was performed with unremarkable findings. One case underwent heart transplantation because of progressive heart failure, Gross findings demonstrated prominent muscular' trabeculations with deep intratrabecular recesses, which coincided well with MRI findings. Conclusion: The MRI manifestation of NVM is characteristic, and MRI with multiple series and planes is helpful in the diagnose of NVM. Compared with echocardiography, MRI could display the pathological cardiac muscle more clearly, because of its high soft

  7. Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.

    Science.gov (United States)

    Long, K J; Bonagura, J D; Darke, P G

    1992-05-01

    Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.

  8. Biomarkers and echocardiography for evaluating the improvement of the ventricular diastolic function after surgical relief of hydronephrosis.

    Science.gov (United States)

    Yeh, Huei-Ming; Lin, Ting-Tse; Yeh, Chih-Fan; Huang, Ho-Shiang; Chang, Sheng-Nan; Lin, Jou-Wei; Tsai, Chia-Ti; Lai, Ling-Ping; Huang, Yi-You; Chu, Chun-Lin

    2017-01-01

    The pathophysiology of cardio-renal syndrome (CRS) is complex. Hydronephrosis caused by urolithiasis may cause cytokine release and lead to cardiac dysfunction. The aim of this study was to evaluate cardiac function changes observed in patients who received double J placement using feasible biomarkers and echocardiography. This was a prospective, single-center study. Eighty-seven patients who presented with acute unilateral hydronephrosis and received ureteroscope stone manipulation were enrolled. Echocardiography and cytokines were measured on the day of the operation and 24 hours after the procedure. Changes before and after surgery were assessed by the paired t-test and Wilcoxon test. Correlation analyses between echocardiographic diastolic indices and cytokine levels were performed using Pearson's correlation coefficients. Patients with hydronephrosis showed a higher left atrium volume index (LAVI), decreased E', and increased E/ E' ratio, which indicated diastolic dysfunction. Patients with hydronephrosis also exhibited decreased global strain rates during isovolumetric relaxation (SRIVR) and E/ SRIVR, which confirmed the diastolic dysfunction. Significant reductions in LAVI, increases in SRIVR and decreases in E/ SRIVR were observed after the operation. Biomarkers, such as TGF-β and serum NT-proBNP, were significantly decreased after surgery. In addition, a significant correlation was observed between the post-surgical decrease in TGF-β1 and increase in SRIVR. Unilateral hydronephrosis causes cardiac diastolic dysfunction, and relieving hydronephrosis could improve diastolic function. Improvements in cardiac dysfunction can be evaluated by echocardiography and measuring cytokine levels. The results of this study will inform efforts to improve the early diagnosis of CRS and prevent further deterioration of cardiac function when treating patients with hydronephrosis.

  9. Exercise stress echocardiography in patients with valvular heart disease.

    Science.gov (United States)

    Sharma, Vishal; Newby, David E; Stewart, Ralph A H; Lee, Mildred; Gabriel, Ruvin; Van Pelt, Niels; Kerr, Andrew J

    2015-09-01

    Stress echocardiography is recommended for the assessment of asymptomatic patients with severe valvular heart disease (VHD) when there is discrepancy between symptoms and resting markers of severity. The aim of this study is to determine the prognostic value of exercise stress echocardiography in patients with common valve lesions. One hundred and fifteen patients with VHD (aortic stenosis (n=28); aortic regurgitation (n=35); mitral regurgitation, (n=26); mitral stenosis (n=26)), and age- and sex-matched controls (n=39) with normal ejection fraction underwent exercise stress echocardiography. The primary endpoint was a composite of death or hospitalization for heart failure. Asymptomatic VHD patients had lower exercise capacity than controls and 37% of patients achieved 60 mmHg) was associated with an increased risk of death or hospital admission (14% vs 1%, P<0.0001). The assessment of contractile reserve did not offer additional predictive value. In conclusion, an abnormal stress echocardiogram is associated with death and hospitalization with heart failure at 2 years. Stress echocardiography should be considered as part of the routine follow-up of all asymptomatic patients with VHD.

  10. Simulation for transthoracic echocardiography of aortic valve

    Science.gov (United States)

    Nanda, Navin C.; Kapur, K. K.; Kapoor, Poonam Malhotra

    2016-01-01

    Simulation allows interactive transthoracic echocardiography (TTE) learning using a virtual three-dimensional model of the heart and may aid in the acquisition of the cognitive and technical skills needed to perform TTE. The ability to link probe manipulation, cardiac anatomy, and echocardiographic images using a simulator has been shown to be an effective model for training anesthesiology residents in transesophageal echocardiography. A proposed alternative to real-time reality patient-based learning is simulation-based training that allows anesthesiologists to learn complex concepts and procedures, especially for specific structures such as aortic valve. PMID:27397455

  11. Digital echocardiography and telemedicine applications in pediatric cardiology.

    Science.gov (United States)

    Sable, Craig

    2002-01-01

    Digital echocardiography offers several advantages over videotape, including easy review, comparison, storage, postprocessing, and sharing of studies, quantitative analysis, and superior resolution. Newer echocardiography systems can write digital data to computer hardware, whereas older systems require digitization of analog data. Clinical and digital data compression is required to reduce study size. Clinical compression has been validated in several adult studies and one pediatric study. JPEG and MPEG digital compression ratios of 26:1 and 200:1, respectively, approximate S-videotape quality. JPEG is the DICOM 3.0 standard and is ideal for short loops, serial comparisons, and quantitative analysis. MPEG (the motion picture standard) lends itself to digitization of video streams and may be more attractive to pediatric cardiologists. Options for data storage and transfer range from limited local review to multiple offline review stations linked by a wide-area network. Telemedicine expands the capabilities of digital echocardiography in a "store and forward" or "real-time" format. Real-time neonatal telecardiology is accurate, impacts patient care, is cost-effective, and does not increase utilization. Cost, increased reliance on sonographers' skills, lack of accepted standards, and legal, licensure, and billing issues are obstacles to widespread acceptance of digital echocardiography and telemedicine.

  12. Evaluation of prosthetic heart valves by transesophageal echocardiography: problems, pitfalls, and timing of echocardiography

    NARCIS (Netherlands)

    van den Brink, Renee B. A.

    2006-01-01

    Transesophageal echocardiography (TEE) is especially suitable for examination of prosthetic valves because of the proximity of the esophagus to the heart and absence of interference with lungs and ribs. This article reviews normal and abnormal morphologic characteristics of prosthetic valves such as

  13. Echocardiography and cardiac MRI in mutation-negative hypertrophic cardiomyopathy in an older patient: a case defining the need for ICD.

    Science.gov (United States)

    Rodriguez, Fatima; Degnan, Kathleen O; Seidman, Christine E; Mangion, Judy R

    2014-08-01

    We report the case of a 67-year-old man with hypertrophic cardiomyopathy who presented for a second opinion about implantable cardio-defibrillator (ICD) placement after a witnessed syncopal episode. Despite his older age, being mutation-negative, and having a maximal septal thickness of 2.2 cm on echocardiography, he demonstrated rapid progression of myocardial fibrosis on cardiac MRI, correlating to ventricular tachyarrhythmias and syncope. We review the role of echocardiography and cardiac MRI in optimizing medical care for such patients who may not otherwise meet criteria for an ICD placement or further interventions. © 2014, Wiley Periodicals, Inc.

  14. Recommendations for fetal echocardiography in twin pregnancy in 2016

    Directory of Open Access Journals (Sweden)

    Leszczyńska Katarzyna

    2016-01-01

    Full Text Available Progress in the fields of fetal cardiology and fetal surgery have been seen not only in singleton pregnancies but also in multiple pregnancies. Proper interpretation of prenatal echocardiography is critical to clinical decision making, family counseling and perinatal management for obstetricians, maternal fetal medicine specialists, neonatologists and pediatric cardiologists. Fetal echocardiography is one of the most challenging and time-consuming prenatal examinations to perform, especially in multiple gestations. Performing just the basic fetal exam in twin gestations may take an hour or more. Thus, it is not practical to perform this exam in all cases of multiple gestations. Therefore our review and recommendations are related to fetal echocardiography in twin gestation.

  15. Cardiodiagnostic imaging. MRT, CT, echocardiography and other methods

    International Nuclear Information System (INIS)

    Erbel, R.; Kreitner, K.F.; Barkhausen, J.; Thelen, M.

    2007-01-01

    The book presents a differentiated approach to cardiac imaging. The focus is n cardio-MR/-CT and echocardiography. These are highly complex methods involving new equipment, new protocols and indications. The techniques are new and difficult to learn for everybody concerned. MR, CT and echocardiography must always be viewed in the context of other diagnostic methods. The interdisciplinary approach of the book addresses both radiologists and cardiologists and relies on the vast experience of the authors. The book offers more than 500 large high-quality reference images reflecting the latest state of the art. It has amethodological section in which the current methods are described (X-ray, echocardiography, nuclear medicine, angiography, CT, MRT etc.) along with their advantages and shortcomings, and a clinical section in which the main indications are described in the common standardized way (anatomy, clinical picture, interpretation, differential diagnosis). (orig.)

  16. Cerebral blood flow and brain atrophy correlated by xenon contrast CT scanning

    International Nuclear Information System (INIS)

    Kitagawa, Y.; Meyer, J.S.; Tanahashi, N.; Rogers, R.L.; Tachibana, H.; Kandula, P.; Dowell, R.E.; Mortel, K.F.

    1985-01-01

    Correlations between cerebral blood flow (CBF) measured during stable xenon contrast CT scanning and standard CT indices of brain atrophy were investigated in the patients with senile dementia of Alzheimer type, multi-infarct dementia and idiopathic Parkinson's disease. Compared to age-matched normal volunteers, significant correlations were found in patients with idiopathic Parkinson's disease between cortical and subcortical gray matter blood flow and brain atrophy estimated by the ventricular body ratio, and mild to moderate brain atrophy were correlated with stepwise CBF reductions. However, in patients with senile dementia of Alzheimer type and multi-infarct dementia, brain atrophy was not associated with stepwise CBF reductions. Overall correlations between brain atrophy and reduced CBF were weak. Mild degrees of brain atrophy are not always associated with reduced CBF

  17. Magnetic resonance imaging compared with echocardiography in the evaluation of pulmonary artery abnormalities in children with tetralogy of Fallot following palliative and corrective surgery

    International Nuclear Information System (INIS)

    Greenberg, S.B.; Crisci, K.L.; Koenig, P.; Robinson, B.; Anisman, P.; Russo, P.

    1997-01-01

    Background. Abnormalities of the pulmonary arteries following palliative or corrective surgery for tetralogy of Fallot (TOF) are common. Our purpose was to compare the usefulness of magnetic resonance imaging (MRI) and echocardiography in the post- operative evaluation of the pulmonary arteries in children with TOF. Objective. Our hypothesis was that MRI is more sensitive than echocardiography in the detection of branch pulmonary artery abnormalities in children with TOF. Materials and methods. Pulmonary artery MRI and echocardiography were performed in 20 children following palliative and/or corrective surgery for TOF. MRI and echocardiography were compared in their ability to detect abnormalities of the pulmonary arteries. Angiographic or surgical correlation was available in 15 children. A perfusion scan for confirmation of pulmonary artery patency was available in one additional child. Results. Abnormalities of the branch pulmonary arteries identified by MRI included: absence or occlusion (2), focal stenosis (15), hypoplasia (2), aneurysm (1), and non-confluence (1). Echocardiography could not adequately visualize the right and left branch pulmonary arteries in eight and ten children, respectively. Echocardiography missed stenosis in 13 branch pulmonary arteries, patency of hypoplastic pulmonary arteries in two children, non-confluence of the pulmonary arteries in one child, and a left pulmonary artery aneurysm in one child. Abnormalities identified by MRI were confirmed in 16 children by angiography, surgery or perfusion scan. Conclusion. MRI is more sensitive than echocardiography for the evaluation of branch pulmonary artery abnormalities in children following surgery for TOF. (orig.)

  18. Contrast Runoff Correlates with the Clinical Outcome of Cervical Epidural Neuroplasty Using a Racz Catheter.

    Science.gov (United States)

    Han, Yun-Joung; Lee, Myoung No; Cho, Min Ji; Park, Hue Jung; Moon, Dong Eon; Kim, Young Hoon

    2016-01-01

    Epidural neuroplasty using a Racz catheter has a therapeutic effect. Studies have found no correlation between foraminal stenosis and the outcome of epidural neuroplasty, which is thought to depend on contrast runoff. To examine the correlation between the contrast spread pattern and pain reduction in cervical epidural neuroplasty using a Racz catheter. Retrospective study. An interventional pain-management practice in a university hospital. Fluoroscopic images were reviewed retrospectively. The spread of contrast from the neural foramen to a nerve root was called contrast runoff. If the contrast did not spread in this manner, then there was no contrast runoff. We defined successful epidural neuroplasty as a 50% or greater reduction from the pre-procedure numeric rating scale (NRS) score for total pain, and an at least 40% reduction in the neck pain and disability scale (NPDS) score. This study reviewed 169 patients. Among the patients who had a contrast runoff pattern, the epidural neuroplasty was rated as successful in 96 (74.4%), 97 (75.2%), 86 (66.7%), and 79 (61.2%) cases one, 3, 6, and 12 months after the procedure, respectively. When there was no contrast runoff, the epidural neuroplasty was successful in 12 (30%), 12 (30%), 10 (25%), and 10 (25%) cases at one, 3, 6, and 12 months after the procedure (P runoff pattern had odds ratios of 6.788, 7.073, 6.000, and 4.740 at one, 3, 6, and 12 months, respectively (P runoff pattern had a higher success rate. Contrast runoff should be observed during neuroplasty, even in the presence of foraminal stenosis. Cervical spinal pain, contrast, contrast runoff, epidural neuroplasty, percutaneous adhesiolysis, Racz catheter.

  19. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  20. Determination of differences in the left ventricular ejection fraction (LVEF) by radionuclides and echocardiography pre and post treatment with anthracycline in pediatric patients with oncology diagnostic of the La Raza Medical Center

    International Nuclear Information System (INIS)

    Veras R, H.

    2003-01-01

    The objective of this work was to correlate the left ventricular ejection fraction determine by radionuclide angiocardiography and echocardiography in pediatric patients under anthracycline treatment. Material and methods: 41 patients were studied with range age from 3 to 14 years, with oncology diagnostic that were treated with anthracycline. Radionuclide angiocardiography and echocardiography were performed before an after anthracycline administration to determine the changes in the Ieft ventricular ejection fraction. Results: Anthracycline treatment caused no changes in the electrocardiography, echocardiogram and radionuclide angiocardiography. Conclusions: In our study anthracycline treatment caused no changes in the electrocardiography, echocardiography and both radionuclide angiocardiography techniques, first-pass and equilibrium. A high correlation was obtaining when left ventricular ejection fraction is compared between radionuclide angiocardiography and echocardiogram. (Author)

  1. Integrated quadruple stress echocardiography.

    Science.gov (United States)

    Picano, Eugenio; Morrone, Doralisa; Scali, Maria C; Huqi, Alda; Coviello, Katia; Ciampi, Quirino

    2018-04-11

    Stress Echocardiography (SE) is an established diagnostic technique. For 40 years, the cornerstone of the technique has been the detection of regional wall motion abnormalities (RWMA), due to the underlying physiologically-relevant epicardial coronary artery stenosis. In the last decade, three new parameters (more objective than RWMA) have shown the potential to integrate and comple- ment RWMA: 1- B-lines, also known as ultrasound lung comets, as a marker of extra-vascular lung water, measured using lung ultrasound with the 4-site simplified scan symmetrically of the antero- lateral thorax on the third intercostal space, from mid-axillary to anterior axillary and mid- clavicular line; 2-left ventricular contractile reserve (LVCR), assessed as the peak stress/rest ratio of left ventricular force, also known as elastance (systolic arterial pressure by cuff sphygmomanome- ter/end-systolic volume from 2D echocardiography); 3- coronary flow velocity reserve (CFVR) on left anterior descending coronary artery, calculated as peak stress/rest ratio of diastolic peak flow velocity assessed using pulsed-wave Doppler. The 4 parameters (RWMA, B-lines, LVCR and CFVR) now converge conceptually, logistically, and methodologically in the Integrated Quadruple (IQ)-SE. IQ-SE optimizes the versatility of SE to include in a one-stop shop the core "ABCD" (Asynergy+B-lines+Contractile reserve+Doppler flowmetry) protocol. It allows a synoptic assess- ment of parameters mirroring the epicardial artery stenosis (RWMA), interstitial lung water (B- lines), myocardial function (LVCR) and small coronary vessels (CFVR). Each variable has a clear clinical correlate, different and complementary to all others: RWMA identify an ischemic vs non- ischemic heart; B-lines a wet vs dry lung; LVCR a strong vs weak heart; CFVR a warm vs cold heart. IQ-SE is highly feasible, with minimal increase in the imaging and analysis time, and obvi- ous diagnostic and prognostic impact also beyond coronary artery

  2. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  3. Cardiovascular assessment of patients with Ullrich-Turner's Syndrome on Doppler echocardiography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Castro Ana Valéria Barros de

    2002-01-01

    Full Text Available OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta. Their ages ranged from 10 to 28 (mean of 16.7 years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%; 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7, mosaics (n=5, and deletions (n=3. No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively. This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.

  4. Visualization of a Small Ventricular Septal Defect at First-pass Contrast-enhanced Cardiac Magnetic Resonance Imaging

    Directory of Open Access Journals (Sweden)

    Francesco Secchi

    2013-01-01

    Full Text Available Ventricular septal defect (VSD is a congenital heart disease that accounts for up to 40% of all congenital cardiac malformations. VSD is a connection between right and left ventricle, through the ventricular septum. Echocardiography and magnetic resonance imaging (MRI help identify this entity. This case presents a 12-year-old male diagnosed with a small muscular apical VSD of 3 mm in diameter, at echocardiography. Cardiac MRI using first-pass perfusion sequence, combining the right plane of acquisition with a short bolus of contrast material, clearly confirmed the presence of VSD.

  5. Simulation-based training in echocardiography.

    Science.gov (United States)

    Biswas, Monodeep; Patel, Rajendrakumar; German, Charles; Kharod, Anant; Mohamed, Ahmed; Dod, Harvinder S; Kapoor, Poonam Malhotra; Nanda, Navin C

    2016-10-01

    The knowledge gained from echocardiography is paramount for the clinician in diagnosing, interpreting, and treating various forms of disease. While cardiologists traditionally have undergone training in this imaging modality during their fellowship, many other specialties are beginning to show interest as well, including intensive care, anesthesia, and primary care trainees, in both transesophageal and transthoracic echocardiography. Advances in technology have led to the development of simulation programs accessible to trainees to help gain proficiency in the nuances of obtaining quality images, in a low stress, pressure free environment, often with a functioning ultrasound probe and mannequin that can mimic many of the pathologies seen in living patients. Although there are various training simulation programs each with their own benefits and drawbacks, it is clear that these programs are a powerful tool in educating the trainee and likely will lead to improved patient outcomes. © 2016, Wiley Periodicals, Inc.

  6. Exercise echocardiography in asymptomatic survivors of childhood cancer treated with anthracyclines

    DEFF Research Database (Denmark)

    Sieswerda, Elske; Kremer, Leontien C M; Vidmar, Suzanna

    2010-01-01

    BACKGROUND: Exercise echocardiography reveals abnormalities in asymptomatic childhood cancer survivors who previously have been treated with anthracyclines. We determined the added value of monitoring childhood cancer survivors with exercise echocardiography compared to monitoring with resting ec...

  7. Targeted neonatal echocardiography services: need for standardized training and quality assurance.

    LENUS (Irish Health Repository)

    Finan, Emer

    2014-10-01

    Targeted neonatal echocardiography refers to a focused assessment of myocardial performance and hemodynamics directed by a specific clinical question. It has become the standard of care in many parts of the world, but practice is variable, and there has been a lack of standardized training and evaluation to date. Targeted neonatal echocardiography was first introduced to Canada in 2006. The purpose of this study was to examine the characteristics of targeted neonatal echocardiography practice and training methods in Canadian neonatal intensive care units (NICUs).

  8. The diagnostic ability of echocardiography for infective endocarditis and its associated complications.

    Science.gov (United States)

    Vilacosta, Isidre; Olmos, Carmen; de Agustín, Alberto; López, Javier; Islas, Fabián; Sarriá, Cristina; Ferrera, Carlos; Ortiz-Bautista, Carlos; Sánchez-Enrique, Cristina; Vivas, David; San Román, Alberto

    2015-11-01

    Echocardiography, transthoracic and transoesophageal, plays a key role in the diagnosis and prognosis assessment of patients with infective endocarditis. It constitutes a major Duke criterion and is pivotal in treatment guiding. Seven echocardiographic findings are major criteria in the diagnosis of infective endocarditis (IE) (vegetation, abscess, pseudoaneurysm, fistulae, new dehiscence of a prosthetic valve, perforation and valve aneurysm). Echocardiography must be performed as soon as endocarditis is suspected. Transoesophageal echocardiography should be done in most cases of left-sided endocarditis to better define the anatomic lesions and to rule out local complications. Transoesophageal echocardiography is not necessary in isolated right-sided native valve IE with good quality transthoracic examination and unequivocal echocardiographic findings. Echocardiography is a very useful tool to assess the prognosis of patients with IE at any time during the course of the disease. Echocardiographic predictors of poor outcome include presence of periannular complications, prosthetic dysfunction, low left ventricular ejection fraction, pulmonary hypertension and very large vegetations.

  9. DOBUTAMINE STRESS-ECHOCARDIOGRAPHY: POSSIBILITY OF CLINICAL USAGE IN CARDIOLOGY PRACTICE

    Directory of Open Access Journals (Sweden)

    M. A. Saidova

    2016-01-01

    Full Text Available Currently stress-echocardiography or so-called burden echocardiography is essential method of patient examination to reveal latent ischemic heart disease (IHD. That is one of the mostly informative non-invasive methods of IHD diagnosis as well as efficacy evaluation of coronary angioplasty, surgical and pharmacological treatments of IHD. Dobutamine usage as a stress-agent at burden echocardiography allows evaluating not only ischemia but a myocardial vitality in post infarction area as well as clarify severity of valve stenosis, pulmonary hypertension and extent of latent obstruction of exhaust duct of the left ventricle. Method possibilities are presented as well as test protocol, main indications and contraindications.

  10. Magnetic resonance imaging compared with echocardiography in the evaluation of pulmonary artery abnormalities in children with tetralogy of Fallot following palliative and corrective surgery

    Energy Technology Data Exchange (ETDEWEB)

    Greenberg, S.B.; Crisci, K.L.; Koenig, P.; Robinson, B.; Anisman, P.; Russo, P. [St. Christopher`s Hospital for Children, Front Street at Erie Avenue, Philadelphia, PA 19134 (United States)

    1997-12-01

    Background. Abnormalities of the pulmonary arteries following palliative or corrective surgery for tetralogy of Fallot (TOF) are common. Our purpose was to compare the usefulness of magnetic resonance imaging (MRI) and echocardiography in the post- operative evaluation of the pulmonary arteries in children with TOF. Objective. Our hypothesis was that MRI is more sensitive than echocardiography in the detection of branch pulmonary artery abnormalities in children with TOF. Materials and methods. Pulmonary artery MRI and echocardiography were performed in 20 children following palliative and/or corrective surgery for TOF. MRI and echocardiography were compared in their ability to detect abnormalities of the pulmonary arteries. Angiographic or surgical correlation was available in 15 children. A perfusion scan for confirmation of pulmonary artery patency was available in one additional child. Results. Abnormalities of the branch pulmonary arteries identified by MRI included: absence or occlusion (2), focal stenosis (15), hypoplasia (2), aneurysm (1), and non-confluence (1). Echocardiography could not adequately visualize the right and left branch pulmonary arteries in eight and ten children, respectively. Echocardiography missed stenosis in 13 branch pulmonary arteries, patency of hypoplastic pulmonary arteries in two children, non-confluence of the pulmonary arteries in one child, and a left pulmonary artery aneurysm in one child. Abnormalities identified by MRI were confirmed in 16 children by angiography, surgery or perfusion scan. Conclusion. MRI is more sensitive than echocardiography for the evaluation of branch pulmonary artery abnormalities in children following surgery for TOF. (orig.) With 2 figs., 3 tabs., 11 refs.

  11. Fetal Intelligent Navigation Echocardiography (FINE): a novel method for rapid, simple, and automatic examination of the fetal heart.

    Science.gov (United States)

    Yeo, Lami; Romero, Roberto

    2013-09-01

    To describe a novel method (Fetal Intelligent Navigation Echocardiography (FINE)) for visualization of standard fetal echocardiography views from volume datasets obtained with spatiotemporal image correlation (STIC) and application of 'intelligent navigation' technology. We developed a method to: 1) demonstrate nine cardiac diagnostic planes; and 2) spontaneously navigate the anatomy surrounding each of the nine cardiac diagnostic planes (Virtual Intelligent Sonographer Assistance (VIS-Assistance®)). The method consists of marking seven anatomical structures of the fetal heart. The following echocardiography views are then automatically generated: 1) four chamber; 2) five chamber; 3) left ventricular outflow tract; 4) short-axis view of great vessels/right ventricular outflow tract; 5) three vessels and trachea; 6) abdomen/stomach; 7) ductal arch; 8) aortic arch; and 9) superior and inferior vena cava. The FINE method was tested in a separate set of 50 STIC volumes of normal hearts (18.6-37.2 weeks of gestation), and visualization rates for fetal echocardiography views using diagnostic planes and/or VIS-Assistance® were calculated. To examine the feasibility of identifying abnormal cardiac anatomy, we tested the method in four cases with proven congenital heart defects (coarctation of aorta, tetralogy of Fallot, transposition of great vessels and pulmonary atresia with intact ventricular septum). In normal cases, the FINE method was able to generate nine fetal echocardiography views using: 1) diagnostic planes in 78-100% of cases; 2) VIS-Assistance® in 98-100% of cases; and 3) a combination of diagnostic planes and/or VIS-Assistance® in 98-100% of cases. In all four abnormal cases, the FINE method demonstrated evidence of abnormal fetal cardiac anatomy. The FINE method can be used to visualize nine standard fetal echocardiography views in normal hearts by applying 'intelligent navigation' technology to STIC volume datasets. This method can simplify

  12. Significance of blood-pool scintigraphy and echocardiography in the investigation of left heart ventricle. Stellung von Herzbinnenraumszintigraphie (HBR) und Echokardiographie (Echo) bei der Untersuchung des linken Ventrikels (LV)

    Energy Technology Data Exchange (ETDEWEB)

    Otto, L.; Neumann, G.; Koegler, A.; Wuensche, A.; Schneider, G. (Leipzig Univ., Klinik fuer Radiologie (Germany)); Krosse, B.; Rother, T.; Loebe, M.; Otto, J. (Leipzig Univ., Klinik fuer Innere Medizin (Germany))

    1990-01-01

    Left ventricular ejection (LVEF) was assessed by both radionuclide ventriculography and echocardiography. The correlation coefficient of 0.74 revealed a just good agreement. It was better in the range of normal than of pathological values. The analysis of regional wall motion performed by echocardiography was not as reliable as by radionuclide ventriculography. The main advantage of echocardiography is its good spatial resolution. Its domain is the diagnostics of pathomorphological changes including valvular disorders. Advantages of radionuclide ventriculography are good temporal resolution, registration of the third dimension, practicability during exercise and as bed side method (nuclear stethoscope). Functional disturbances of both ventricles are its field of application. (orig.).

  13. A guideline update for the practice of echocardiography in the cardiac screening of sports participants: a joint policy statement from the British Society of Echocardiography and Cardiac Risk in the Young

    Directory of Open Access Journals (Sweden)

    David Oxborough PhD

    2018-03-01

    Full Text Available Sudden cardiac death (SCD in an athlete is a rare but tragic event. In view of this, pre-participation cardiac screening is mandatory across many sporting disciplines to identify those athletes at risk. Echocardiography is a primary investigation utilized in the pre-participation setting and in 2013 the British Society of Echocardiography and Cardiac Risk in the Young produced a joint policy document providing guidance on the role of echocardiography in this setting. Recent developments in our understanding of the athlete’s heart and the application of echocardiography have prompted this 2018 update.

  14. Evaluation of echocardiography in the management of elderly patients with heart failure.

    Science.gov (United States)

    Hendry, A; Hacking, L; Langhorne, P; Vallance, R; MacDonald, J

    1999-09-01

    To determine the validity of a clinical diagnosis of systolic dysfunction in elderly patients with heart failure and assess the contribution of echocardiography to their management. 61 elderly patients with a diagnosis of heart failure in a geriatric assessment unit setting. Prospective study determining sensitivity, specificity and predictive values of a clinical and radiological diagnosis compared with echocardiographic standard. Proposed management was compared before and after echocardiography. Clinical assessment was highly sensitive (93%) but lacked specificity (32%). Combining radiological and clinical diagnoses increased specificity to 58%. Echocardiography revised the lead cardiac diagnosis for 28% of patients and influenced patient management plans for 41%. For elderly patients with heart failure, echocardiography improves diagnostic accuracy and identifies those patients with potential to benefit from angiotensin-converting enzyme inhibitors.

  15. Echocardiography in patients with complications related to pacemakers and cardiac defibrillators.

    Science.gov (United States)

    Almomani, Ahmed; Siddiqui, Khadija; Ahmad, Masood

    2014-03-01

    The evolving indications and uses for implantable cardiac devices have led to a significant increase in the number of implanted devices each year. Implantation of endocardial leads for permanent pacemakers and cardiac defibrillators can cause many delayed complications. Complications may be mechanical and related to the interaction of the device leads with the valves and endomyocardium, e.g., perforation, infection, and thrombosis, or due to the electrical pacing of the myocardium and conduction abnormalities, e.g., left ventricular dyssynchrony. Tricuspid regurgitation, another delayed complication in these patients, may be secondary to both mechanical and pacing effects of the device leads. Echocardiography plays an important role in the diagnosis of these device-related complications. Both two-dimensional transthoracic echocardiography and transesophageal echocardiography provide useful diagnostic information. Real time three-dimensional echocardiography is a novel technique that can further enhance the detection of lead-related complications. © 2013, Wiley Periodicals, Inc.

  16. Intraoperative echocardiography of a dislodged Björk-Shiley mitral valve disc.

    Science.gov (United States)

    Tanaka, M; Abe, T; Takeuchi, E; Watanabe, T; Tamaki, S

    1991-02-01

    The successful management of a patient who suffered an outlet strut fracture of a Björk-Shiley 60-degree convexo-concave mitral valve prosthesis is reported. Emergency operation was life-saving. Preoperative echocardiography assisted in making a prompt diagnosis, and intraoperative echocardiography allowed the detection and removal of the dislodged disc from the left ventricle at the time of the operation. The role of intraoperative echocardiography in the diagnosis of prosthetic strut fracture is emphasized.

  17. Transesophageal echocardiography in patients with cryptogenic cerebral ischemia

    Directory of Open Access Journals (Sweden)

    Dreger Henryk

    2009-03-01

    Full Text Available Abstract Background In about one third of all patients with cerebral ischemia, no definite cause can be identified (cryptogenic stroke. In many patients with initially suspected cryptogenic stroke, however, a cardiogenic etiology can eventually be determined. Hence, the aim of this study was to describe the prevalence of abnormal echocardiographic findings in a large number of these patients. Method Patients with cryptogenic cerebral ischemia (ischemic stroke, IS, and transient ischemic attack, TIA were included. The initial work-up included a neurological examination, EEG, cCT, cMRT, 12-lead ECG, Holter-ECG, Doppler ultrasound of the extracranial arteries, and transthoracic echocardiography. A multiplane transeophageal echocardiography (TEE, including i.v. contrast medium application [Echovist], Valsalva maneuver was performed in all patients Results 702 consecutive patients (380 male, 383 IS, 319 TIA, age 18–90 years were included. In 52.6% of all patients, TEE examination revealed relevant findings. Overall, the most common findings in all patients were: patent foramen ovale (21.7%, previously undiagnosed valvular disease (15.8%, aortic plaques, aortic valve sclerosis, atrial septal aneurysms, regional myocardial dyskinesia, dilated left atrium and atrial septal defects. Older patients (> 55 years, n = 291 and patients with IS had more relevant echocardiographic findings than younger patients or patients with TIA, respectively (p = 0.002, p = 0.003. The prevalence rates of PFO or ASD were higher in younger patients (PFO: 26.8% vs. 18.0%, p = 0.005, ASD: 9.6% vs. 4.9%, p = 0.014. Conclusion A TEE examination in cryptogenic stroke reveals contributing cardiogenic factors in about half of all patients. Younger patients had a higher prevalence of PFO, whereas older patients had more frequently atherosclerotic findings. Therefore, TEE examinations seem indicated in all patients with cryptogenic stroke – irrespective of age – because of

  18. Visualization of traumatic tricuspid insufficiency by three-dimensional echocardiography.

    Science.gov (United States)

    Nishimura, Kazuhisa; Okayama, Hideki; Inoue, Katsuji; Saito, Makoto; Nagai, Takayuki; Suzuki, Jun; Ogimoto, Akiyoshi; Ohtsuka, Tomoaki; Higaki, Jitsuo

    2010-01-01

    A 19-year-old male was admitted to the emergency room of our hospital after a motor vehicle accident. During his first physical examination, a holosystolic murmur was heard at the fourth left parasternal border. Transthoracic echocardiography showed severe tricuspid insufficiency, but the cause of tricuspid insufficiency was unclear. Therefore, three-dimensional echocardiography was performed and demonstrated flail anterior, posterior and septal leaflets of the tricuspid valve. The diagnosis was tricuspid insufficiency due to papillary muscle rupture secondary to chest blunt trauma. Surgical repair of the tricuspid valve was performed in this patient. After surgery, the signs and symptoms of right ventricular heart failure were relieved. In this case, three-dimensional echocardiography was very useful for the evaluation of spatial destruction of the tricuspid valve and papillary muscle. 2009 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  19. Usefulness of exercise echocardiography in ischemic heart disease. Comparison with exercise cardiac scintigraphy

    International Nuclear Information System (INIS)

    Tashiro, Hideki; Koyanagi, Samon; Narabayashi, Hideki; Inou, Tetsuji; Takeshita, Akira

    1999-01-01

    Exercise echocardiography and exercise thallium-201 ( 201 Tl) single photon emission computed tomography (SPECT) were performed in 152 patients with suspected coronary artery disease, including 61 patients with old myocardial infarction. All patients underwent coronary arteriography, and coronary artery disease was defined as ≥75% diameter stenosis. Digital two-dimensional echocardiography was performed before and after the treadmill exercise test, and wall motion abnormality was evaluated using quad-screen. Sensitivity and specificity for the diagnosis of coronary artery disease were similar for the 2 exercise tests (77% and 80% for echocardiography and 75%, and 83% for SPECT, respectively). Diagnoses for one-vessel disease, 2-vessel disease and 3-vessel disease were similar for echocardiography (79%, 72% and 77%, respectively) and SPECT (74%, 75% and 77%, respectively). Sensitivity for the diagnosis of ischemia at the area remote from infarct area was low for both exercise echocardiography and exercise SPECT (45% and 48%, respectively). Exercise echocardiography has comparable diagnostic value to SPECT for the detection of coronary artery disease. However, both exercise tests have limitations for the diagnosis of ischemia at the area remote from infarct area. (author)

  20. Three-dimensional transesophageal echocardiography of the atrial septal defects

    Directory of Open Access Journals (Sweden)

    Romero-Cárdenas Ángel

    2008-07-01

    Full Text Available Abstract Transesophageal echocardiography has advantages over transthoracic technique in defining morphology of atrial structures. Even though real time three-dimensional echocardiographic imaging is a reality, the off-line reconstruction technique usually allows to obtain higher spatial resolution images. The purpose of this study was to explore the accuracy of off-line three-dimensional transesophageal echocardiography in a spectrum of atrial septal defects by comparing them with representative anatomic specimens.

  1. Factors associated with diagnostic discrepancy for left ventricular hypertrophy between electrocardiography and echocardiography

    DEFF Research Database (Denmark)

    Sandager Petersen, Søren; Reinholdt Pedersen, Line; Pareek, Manan

    2017-01-01

    (absolute value/cut-off value for LVH) were used as outcome variables in order to identify explanatory variables associated with diagnostic discrepancies between ECG and echocardiography. RESULTS: Of the 1382 subjects included, 77% did not display any signs of LVH, 6% had LVH defined by ECG only, 13% had...... LVH defined by echocardiography only, and 5% had LVH on both ECG and echocardiography. Older subjects and those with higher blood pressure and RWT were more likely to have a relatively greater LVMI on echocardiography than that predicted on ECG (odds ratio: 1.65 per 10 years (95% confidence interval...... and odds ratio: 1.41 (95% CI: 1.06-1.87), p = .02), but FPG did not independently influence discrepancy between ECG and echocardiography. CONCLUSION: Age, blood pressure, female sex, greater RWT and use of antihypertensive medication were associated with a greater risk of non-consistency between LVH...

  2. Patent foramen ovale and cryptogenic stroke. Echocardiography role and state of the art

    International Nuclear Information System (INIS)

    Jaramillo U, Mario H

    2008-01-01

    The causes of ischemic stroke in young patients are difficult to find, in spite of systematic investigations directed to rule out heart etiology, alterations in coagulation or any other type of vascular disease; hence the cryptogenic definition. There have been speculations regarding the potential role of right-to-left intracardiac shunts as a path for paradoxical embolisms that result in ischemic cerebral disease. Transesophagic echocardiography with peripheral venous injection of saline contrast has shown to be the preferred method for the diagnosis of patent foramen ovale and right-to-left shunt. Prospective studies using acetylsalicylic acid or warfarin have not shown significant reduction of recurrent strokes. Even though both surgical and percutaneous closure of the patent foramen ovale have shown to decrease the rate of subsequent embolic episodes, their indication remains under discussion, at least until the appearance of randomized clinical trials, now under development. However, the cases of recurrent paradoxical embolism and those in professional scuba divers, both with intra-atrial septum aneurysm and an associated patent foramen ovale, are the only unequivocal indications for percutaneous closure. Successful closure, defined by transesophagic echocardiography, seems to predict lack of recurrent embolic events. As the complication rate of device implantation may decrease and these devices become technologically simple, percutaneous closure will prevail over surgical closure

  3. Potential benefit of a simultaneous, side-by-side display of contrast MDCT and echocardiography over routine sequential imaging for assessment of adult congenital heart disease: A preliminary study.

    Science.gov (United States)

    Oe, Hiroki; Watanabe, Nobuhisa; Miyoshi, Toru; Osawa, Kazuhiro; Akagi, Teiji; Kanazawa, Susumu; Ito, Hiroshi

    2018-06-18

    Management of adult congenital heart disease (ACHD) patients requires understanding of its complex morphology and functional features. An innovative imaging technique has been developed to display a virtual multi-planar reconstruction obtained from contrast-enhanced multidetector-computed tomography (MDCT) corresponding to the same cross-sectional image from transthoracic echocardiography (TTE). The aim of this study is to assess the usefulness of this imaging technology in ACHD patients. This study consisted of 46 consecutive patients (30 women; mean age, 52±18 years old) with ACHD who had undergone contrast MDCT. All patients underwent TTE within a week of MDCT. An experienced sonographer who did not know the results of MDCT conducted a diagnosis using TTE and, then, using the new imaging technology. We studied whether this imaging technology provided additional or unexpected findings or makes more accurate diagnosis. In this imaging technology, MDCT cross-section provides higher-resolution image to the deep compared to corresponding TTE image. Depending on the MDCT section which can be arbitrarily set under the echo guide, we can diagnose unexpected or incremental lesions or more accurately assess the severity of the lesion in 27 patients (59%) compared to TTE study alone. This imaging technology was useful in the following situations: CONCLUSIONS: This integrated imaging technology provides incremental role over TTE in complex anatomy, and allows functional information in ACHD patients. Copyright © 2018 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  4. Patent foramen ovale: diagnosis with multidetector CT--comparison with transesophageal echocardiography.

    Science.gov (United States)

    Kim, Young Jin; Hur, Jin; Shim, Chi-Young; Lee, Hye-Jeong; Ha, Jong-Won; Choe, Kyu Ok; Heo, Ji Hoe; Choi, Eui-Young; Choi, Byoung Wook

    2009-01-01

    To evaluate the clinical feasibility and accuracy of 64-section multidetector computed tomography (CT) compared with transesophageal echocardiography (TEE) for diagnosis of a patent foramen ovale (PFO). Institutional review board approval was obtained for this retrospective study. The study included 152 consecutive stroke patients (mean age, 61.7 years; 98 men, 54 women) who underwent both cardiac multidetector CT and TEE. Electrocardiographically gated cardiac CT was performed with a 64-section CT scanner by using a saline-chaser contrast agent injection technique. A contrast agent jet from the contrast agent-filled left atrium (LA) to the saline-filled right atrium (RA) and channel-like appearance of the interatrial septum (IAS) were evaluated on axial and oblique sagittal CT images. Two-dimensional and Doppler TEE were performed to detect PFO. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of CT were obtained with TEE as the reference standard. A PFO was present in 26 patients at TEE. On CT images, a left-to-right contrast agent jet toward the inferior vena cava was noted in 21 patients (sensitivity, 73.1%; specificity, 98.4%; PPV, 90.5%; NPV, 94.7%). Channel-like appearance of the IAS was detected in 38 patients (sensitivity, 76.9%; specificity, 85.7%; PPV, 52.6%; NPV, 94.7%). Channel-like appearance of the IAS was noted in all patients who had a contrast agent jet. A contrast agent jet from LA to RA toward the inferior vena cava with channel-like appearance of the IAS on CT images confirms the presence of a PFO. (c) RSNA, 2008.

  5. Strain Echocardiography Improves Risk Prediction of Ventricular Arrhythmias After Myocardial Infarction

    DEFF Research Database (Denmark)

    Haugaa, Kristina H; Grenne, Bjørnar L; Eek, Christian H

    2013-01-01

    The aim of this study was to test the hypothesis that strain echocardiography might improve arrhythmic risk stratification in patients after myocardial infarction (MI).......The aim of this study was to test the hypothesis that strain echocardiography might improve arrhythmic risk stratification in patients after myocardial infarction (MI)....

  6. Exercise echocardiography for structural heart disease.

    Science.gov (United States)

    Izumo, Masaki; Akashi, Yoshihiro J

    2016-03-01

    Since the introduction of transcatheter structural heart intervention, the term "structural heart disease" has been widely used in the field of cardiology. Structural heart disease refers to congenital heart disease, valvular heart disease, and cardiomyopathy. In structural heart disease, valvular heart disease is frequently identified in the elderly. Of note, the number of patients who suffer from aortic stenosis (AS) and mitral regurgitation (MR) is increasing in developed countries because of the aging of the populations. Transcatheter aortic valve replacement and percutaneous mitral valve repair has been widely used for AS and MR, individually. Echocardiography is the gold standard modality for initial diagnosis and subsequent evaluation of AS and MR, although the difficulties in assessing patients with these diseases still remain. Here, we review the clinical usefulness and prognostic impact of exercise echocardiography on structural heart disease, particularly on AS and MR.

  7. Association between aortic valve calcification measured on non-contrast computed tomography and aortic valve stenosis in the general population.

    Science.gov (United States)

    Paulsen, Niels Herluf; Carlsen, Bjarke Bønløkke; Dahl, Jordi Sanchez; Carter-Storch, Rasmus; Christensen, Nicolaj Lyhne; Khurrami, Lida; Møller, Jacob Eifer; Lindholt, Jes Sandal; Diederichsen, Axel Cosmus Pyndt

    2016-01-01

    Aortic valve calcification (AVC) measured on non-contrast computed tomography (CT) has shown correlation to severity of aortic valve stenosis (AS) and mortality in patients with known AS. The aim of this study was to determine the association of CT verified AVC and subclinical AS in a general population undergoing CT. CT scans from 566 randomly selected male participants (age 65-74) in the Danish cardiovascular screening study (DANCAVAS) were analyzed for AVC. All participants with a moderately or severely increased AVC score (≥300 arbitrary units (AU)) and a matched control group were invited for a supplementary echocardiography. AS was graded by indexed aortic valve area (AVAi) on echocardiography as moderate 0.6-0.85 cm(2)/m(2) and severe AVC scoring. Moderate or severe increased AVC was observed in 10.7% (95% CI: 8.4-13.7). Echocardiography was performed in 101 individuals; 32.7% (95% CI: 21.8 to 46.0) with moderate or high AVC score had moderate or severe AS, while none with no or low AVC. A ROC analysis defined an AVC score ≥588 AU to be suggestive of moderate or severe AS (AUC 0.89 ± 0.04, sensitivity 83% and specificity 87%). In the univariate analyses, AVC was the only variable significantly associated with AS. This study indicates an association between CT verified AVC and subclinical AS. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  8. Correlation Between Contrast Time-Density Time on Digital Subtraction Angiography and Flow: An in Vitro Study.

    Science.gov (United States)

    Brunozzi, Denise; Shakur, Sophia F; Ismail, Rahim; Linninger, Andreas; Hsu, Chih-Yang; Charbel, Fady T; Alaraj, Ali

    2018-02-01

    Digital subtraction angiography (DSA) provides an excellent anatomic characterization of cerebral vasculature, but hemodynamic assessment is often qualitative and subjective. Various clinical algorithms have been produced to semiquantify flow from the data obtained from DSA, but few have tested them against reliable flow values. An arched flow model was created and injected with contrast material. Seventeen injections were acquired in anterior-posterior and lateral DSA projections, and 4 injections were acquired in oblique projection. Image intensity change over the angiogram cycle of each DSA run was analyzed through a custom MATLAB code. Time-density plots obtained were divided into 3 components (time-density times, TDTs): TDT 10%-100% (time needed for contrast material to change image intensity from 10% to 100%), TDT 100%-10% (time needed for contrast material to change image intensity from 100% to 10%), and TDT 25%-25% (time needed for contrast material to change from 25% image intensity to 25%). Time-density index (TDI) was defined as model cross-sectional area to TDT ratio, and it was measured against different flow rates. TDI 10%-100% , TDI 100%-10% , and TDI 25%-25% all correlated significantly with flow (P < 0.001). TDI 10%-100% , TDI 100%-10% , and TDI 25%-25% showed, respectively, a correlation coefficient of 0.91, 0.91, and 0.97 in the anterior-posterior DSA projections (P < 0.001). In the lateral DSA projection, TDI 100%-10% showed a weaker correlation (r = 0.57; P = 0.03). Also in the oblique DSA projection, TDIs correlated significantly with flow. TDI on DSA correlates significantly with flow. Although in vitro studies might overlook conditions that occur in patients, this method appears to correlate with the flow and could offer a semiquantitative method to evaluate the cerebral blood flow. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. [Real time 3D echocardiography

    Science.gov (United States)

    Bauer, F.; Shiota, T.; Thomas, J. D.

    2001-01-01

    Three-dimensional representation of the heart is an old concern. Usually, 3D reconstruction of the cardiac mass is made by successive acquisition of 2D sections, the spatial localisation and orientation of which require complex guiding systems. More recently, the concept of volumetric acquisition has been introduced. A matricial emitter-receiver probe complex with parallel data processing provides instantaneous of a pyramidal 64 degrees x 64 degrees volume. The image is restituted in real time and is composed of 3 planes (planes B and C) which can be displaced in all spatial directions at any time during acquisition. The flexibility of this system of acquisition allows volume and mass measurement with greater accuracy and reproducibility, limiting inter-observer variability. Free navigation of the planes of investigation allows reconstruction for qualitative and quantitative analysis of valvular heart disease and other pathologies. Although real time 3D echocardiography is ready for clinical usage, some improvements are still necessary to improve its conviviality. Then real time 3D echocardiography could be the essential tool for understanding, diagnosis and management of patients.

  10. Standard echocardiography versus handheld echocardiography for the detection of subclinical rheumatic heart disease: protocol for a systematic review.

    Science.gov (United States)

    Telford, Lisa H; Abdullahi, Leila H; Ochodo, Eleanor A; Zühlke, Liesl J; Engel, Mark E

    2018-02-10

    Rheumatic heart disease (RHD) is a preventable and treatable chronic condition which persists in many developing countries largely affecting impoverished populations. Handheld echocardiography presents an opportunity to address the need for more cost-effective methods of diagnosing RHD in developing countries, where the disease continues to carry high rates of morbidity and mortality. Preliminary studies have demonstrated moderate sensitivity as well as high specificity and diagnostic odds for detecting RHD in asymptomatic patients. We describe a protocol for a systematic review on the diagnostic performance of handheld echocardiography compared to standard echocardiography using the 2012 World Heart Federation criteria for diagnosing subclinical RHD. Electronic databases including PubMed, Scopus, Web of Science and EBSCOhost as well as reference lists and citations of relevant articles will be searched from 2012 to date using a predefined strategy incorporating a combination of Medical Subject Heading terms and keywords. The methodological validity and quality of studies deemed eligible for inclusion will be assessed against review specific Quality Assessment of Diagnostic Accuracy Studies 2 criteria and information on metrics of diagnostic accuracy and demographics extracted. Forest plots of sensitivity and specificity as well as scatter plots in receiver operating characteristic (ROC) space will be used to investigate heterogeneity. If possible, a meta-analysis will be conducted to produce summary results of sensitivity and specificity using the Hierarchical Summary ROC method. In addition, a sensitivity analysis will be conducted to investigate the effect of studies with a high risk of bias. Ethics approval is not required for this systematic review of previously published literature. The planned review will provide a summary of the diagnostic accuracy of handheld echocardiography. Results may feed into evidence-based guidelines and should the findings of this

  11. Echocardiography as an approach for canine cardiac disease diagnosis

    Directory of Open Access Journals (Sweden)

    P. Singh

    2014-11-01

    Full Text Available Aim: The aim of the study was to establish the methods for diagnosis various canine cardiac ailments using echocardiography. Materials and Methods: M-mode, two-dimensional echocardiography and Doppler studies were performed on 10 cases. Dogs showing signs of cardiac ailment either clinically, radiographic or via electrocardiographic examination were selected for study. Right parasternal short axis view was used for echocardiographic measurements. Right parasternal long axis and left parasternal apical views were used for Doppler studies. Doppler studies were performed at the level of aortic valve and atrioventricular valves for semi quantitative diagnosis of regurgitation. Results: Dogs were found affected with dilated cardiomyopathy (DCM (n=5, pericardial effusion (PE (n=1, combined PE and DCM (n=2 and remaining two showed abnormality on radiographic or electrographically evaluation but were found out to be normal echocardiographically (n=2. Conclusion: Echocardiography is an effective tool for diagnosis of various heart ailments.

  12. Gated blood pool tomography for the evaluation of global and regional left ventricular function in comparison to planar techniques and echocardiography.

    Science.gov (United States)

    Canclini, S; Terzi, A; Rossini, P; Vignati, A; La Canna, G; Magri, G C; Pizzocaro, C; Giubbini, R

    2001-01-01

    Multigated radionuclide ventriculography (MUGA) is a simple and reliable tool for the assessment of global systolic and diastolic function and in several studies it is still considered a standard for the assessment of left ventricular ejection fraction. However the evaluation of regional wall motion by MUGA is critical due to two-dimensional imaging and its clinical use is progressively declining in favor of echocardiography. Tomographic MUGA (T-MUGA) is not widely adopted in clinical practice. The aim of this study was to compare T-MUGA to planar MUGA (P-MUGA) for the assessment of global ejection fraction and to transthoracic echocardiography for the evaluation of regional wall motion. A 16-segment model was adopted for the comparison with echo regional wall motion. For each one of the 16 segments the normal range of T-MUGA ejection fraction was quantified and a normal data file was defined; the average value -2.5 SD was used as the lower threshold to identify abnormal segments. In addition, amplitude images from Fourier analysis were quantified and considered abnormal according to three different thresholds (25, 50 and 75% of the maximum). In a study group of 33 consecutive patients the ejection fraction values of T-MUGA highly correlated with those of P-MUGA (r = 0.93). The regional ejection fraction (according to the normal database) and the amplitude analysis (50% threshold) allowed for the correct identification of 203/226 and 167/226 asynergic segments by echocardiography, and of 269/302 and 244/302 normal segments, respectively. Therefore sensitivity, specificity and overall accuracy to detect regional wall motion abnormalities were 90, 89, 89% and 74, 81, 79% for regional ejection fraction and amplitude analysis, respectively. T-MUGA is a reliable tool for regional wall motion evaluation, well correlated with echocardiography, less subjective and able to provide quantitative data.

  13. Small, smooth, nonmobile cardiac myxoma detected by transesophageal echocardiography following recurrent cerebral infarction: a case report.

    Science.gov (United States)

    Saito, Yuki; Aizawa, Yoshihiro; Monno, Koyuru; Nagashima, Koichi; Kurokawa, Sayaka; Osaka, Shunji; Akimoto, Takayoshi; Kamei, Satoshi; Tanaka, Masashi; Hirayama, Atsushi

    2017-05-10

    Cardiac myxoma is known to cause repeated events of cerebral embolism. Soft and irregularly shaped myxomas with high mobility are associated with a higher occurrence of cerebral embolism. In contrast, nonmobile cardiac myxomas with a round regular shape are rarely considered to be a cause of cerebral embolism. In this case, we present a patient with recurrent cerebral embolism associated with a small and nonmobile cardiac myxoma of round regular shape. A 76-year-old Japanese man presented to our hospital with weakness in his right upper extremity. He had a history of right frontal lobe infarction in the previous month. T2-weighted magnetic resonance imaging revealed an area of hyperintensity in the left precentral gyrus, indicating acute cerebral infarction. Transthoracic echocardiography revealed normal left ventricular function and no abnormalities. However, transesophageal echocardiography showed a small and nonmobile left atrial tumor with round regular shape attached to the ostium secundum of the atrial septum. Based on these findings, we diagnosed recurrent cerebral infarction due to embolization caused by left atrial myxoma, and cardiac tumor extraction was performed on hospitalization day 36. The excised tumor measured 0.6 × 0.6 × 0.5 cm and was diagnosed as cardiac myxoma by histologic examination. Even small and nonmobile cardiac myxomas with a round regular shape may cause recurrent cerebral infarction. The diagnosis of this type of atrial myxoma is elusive and transesophageal echocardiography was an effective method of detection. In a clinical situation, this type of cardiac myxoma may be overlooked as a cause of cerebral infarction.

  14. The Role of Echocardiography in Coronary Artery Disease and Acute Myocardial Infarction

    Science.gov (United States)

    Esmaeilzadeh, Maryam; Parsaee, Mozhgan; Maleki, Majid

    2013-01-01

    Echocardiography is a non-invasive diagnostic technique which provides information regarding cardiac function and hemodynamics. It is the most frequently used cardiovascular diagnostic test after electrocardiography and chest X-ray. However, in a patient with acute chest pain, Transthoracic Echocardiography is essential both for diagnosing acute coronary syndrome, zeroing on the evaluation of ventricular function and the presence of regional wall motion abnormalities, and for ruling out other etiologies of acute chest pain or dyspnea, including aortic dissection and pericardial effusion. Echocardiography is a versatile imaging modality for the management of patients with chest pain and assessment of left ventricular systolic function, diastolic function, and even myocardial and coronary perfusion and is, therefore, useful in the diagnosis and triage of patients with acute chest pain or dyspnea. This review has focused on the current applications of echocardiography in patients with coronary artery disease and myocardial infarction. PMID:23646042

  15. Cardiac MR imaging: Comparison with echocardiography and dynamic CT

    International Nuclear Information System (INIS)

    Colletti, P.M.; Norris, S.; Raval, J.; Boswell, W.; Lee, K.; Ralls, P.; Haywood, J.; Halls, J.

    1986-01-01

    The authors compared gated cardiac MR imaging with two-dimensional and Doppler echocardiography and dynamic CT. Gated cardiac MR imaging (VISTA unit, 0.5 T) was performed in 55 patients with a variety of conditions. Accuracy of diagnosis was compared. CT showed arterial, valvular, and pericardial calcifications not seen on MR imaging. Many lesions were seen as well on CT as on MR imaging. Two-dimensional echocardiography was superior in demonstrating wall motion and valvular disease. MR imaging was superior in demonstrating myocardial structures

  16. Correlation Between Bile Reflux Gastritis and Biliary Excreted Contrast Media in the Stomach.

    Science.gov (United States)

    Hyun, Jong Jin; Yeom, Suk Keu; Shim, Euddeum; Cha, Jaehyung; Choi, Inyoung; Lee, Seung Hwa; Chung, Hwan Hoon; Cha, Sang Hoon; Lee, Chang Hee

    This study aimed to evaluate the relationship between biliary excreted contrast media in the stomach and the presence of bile reflux gastritis. Consecutive 111 patients who underwent both gadoxetic acid-enhanced magnetic resonance cholangiography (gadoxetic MRC) and gastric endoscopy were included in this study. We performed a review of the gadoxetic-MRC image sets acquired 60 minutes after intravenous injection of contrast media and endoscopic images. We recorded amount of contrast media in the stomach. The sensitivity, specificity, and accuracy of duodenogastric bile reflux diagnosis were evaluated for the gadoxetic MRC. Statistical analysis was performed using the Fisher exact test and the linear-by-linear association test. Among the 111 patients, 39 had 60-minute delayed images showing the presence of contrast media in the stomach. Of these 39 patients, 13 had bile reflux gastritis and 5 showed bile in the stomach without evidence of erythematous gastritis. Of the 72 patients who did not show contrast media in the stomach, none had bile reflux gastritis and 2 patients showed bile staining in the stomach without evidence of erythematous gastritis. Bile reflux gastritis was significantly more frequent in patients with contrast media in the stomach on gadoxetic MRC than in those without. Patients with high-grade extension of contrast media in the stomach had significantly frequent bile reflux gastritis than did those with low-grade extension. Biliary excreted contrast media in the stomach on 60-minute delayed gadoxetic MRC has a correlation with the presence of bile reflux gastritis on endoscopic examination.

  17. Contrast-enhanced color Doppler US in breast cancer: Tumoral vascularity correlated with angiogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun A; Yoon, Kwon Ha; Yun, Ki Jung; Lee, Kwang Man; Park, Ki Han; Juhng, Seon Kwan; Won, Jong Jin [Wonkwang University School of Medicine, Seoul (Korea, Republic of)

    2000-12-15

    To evaluate the effects of contrast-enhanced color Doppler ultrasonography (CDUS) on the depiction of vascularity and flow pattern in breast cancer and to determine the relationship between tumoral vascularity and angiogenesis. Twenty-one patients with breast cancer were prospectively evaluated with CDUS before and after injection of the contrast agent (SH U 508A, 2.5g, 300 mg/ml ). The tumoral vascularity was expressed as percentage of color Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The flow pattern (four-patterns; spotty, linear, branching, marginal) of the vascularity was analyzed. After surgery, tumor angiogenesis was assessed by microvessel density. The relationship between the vascularity on CDUS and microvessel density was statistically analyzed. At unenhanced CDUS, tumoral flow signals were detected in 12 lesions (48%); at contrast-enhanced CDUS, 18 lesions (86%). All These 18 lesions showed increased signals, compared with those at unenhanced CDUS. The percentage color Doppler area was 1.86 {+-} 0.48% at unenhanced CDUS and 5.23 {+-} 1.18% at contrast-enhanced CDUS. The flow patterns before contrast injection were spotty pattern in 11 tumors and linear pattern in one; after contrast injection, spotty in 8, linear in 4, branching in 5, and marginal in one. The tumoral vascularity at contrast-enhanced CDUS showed no significant correlation with microvessel density. Contrast-enhanced CDUS seems to be a valuable tool in the depiction of vascularity and characterization of flow pattern in breast cancer. However, tumoral vascularity on CDUS may not reflect tumoral angiogenesis.

  18. Effectiveness of simulator-based echocardiography training of noncardiologists in congenital heart diseases.

    Science.gov (United States)

    Wagner, Robert; Razek, Vit; Gräfe, Florentine; Berlage, Thomas; Janoušek, Jan; Daehnert, Ingo; Weidenbach, Michael

    2013-07-01

    Congenital heart diseases (CHD) are responsible for substantial morbidity and mortality in neonates. The preliminary diagnosis often is made by noncardiologists. For this reason, there is a huge demand of training in echocardiography of CHD. This is difficult to achieve due to limited resources of specialized centers. The goal of this study was to investigate the training effect of the echocardiography simulator EchoCom on trainee's ability to diagnose CHD. We enrolled 10 residents for simulator-based training in echocardiography of CHD. All participants were instructed on the simulator's basic handling and had one hour to scan the first 9 datasets information (ventricular septal defect, atrial septal defect, atrioventricular septal defect, Tetralogy of Fallot, transposition of great arteries, congenital corrected transposition of great arteries, common arterial trunk, hypoplastic left heart syndrome, normal anatomy) and establish a diagnosis. No help was given except for support regarding simulator related issues. Afterward, 2 rounds of structured simulator based echocardiography training focused on echocardiographic anatomy, spatial orientation, standard views, and echocardiographic anatomy of different CHD followed. All participants completed a standardized questionnaire containing 10 multiple-choice (MC) questions focusing on basic theoretical knowledge in echocardiographic anatomy and common CHD. Almost all of the residents invited from the affiliated children's hospital had little (20%) or no experience (80%) in echocardiography of CHD. Their Pretest and Posttest scores showed significant improvement for both, MC test and performance test, respectively. Our study showed that simulator-based training in echocardiography in CHD could be very effective and may assist with training outside the scope of CHD. © 2013, Wiley Periodicals, Inc.

  19. Dobutamine stress echocardiography in healthy adult male rats

    Directory of Open Access Journals (Sweden)

    Couet Jacques

    2005-10-01

    Full Text Available Abstract Background Dobutamine stress echocardiography is used to investigate a wide variety of heart diseases in humans. Dobutamine stress echocardiography has also been used in animal models of heart disease despite the facts that the normal response of healthy rat hearts to this type of pharmacological stress testing is unknown. This study was performed to assess this normal response. Methods 15 normal adult male Wistar rats were evaluated. Increasing doses of dobutamine were infused intravenously under continuous imaging of the heart by a 12 MHz ultrasound probe. Results Dobutamine stress echocardiography reduced gradually LV diastolic and systolic dimensions. Ejection fraction increased by a mean of +24% vs. baseline. Heart rate increased progressively without reaching a plateau. Changes in LV dimensions and ejection fraction reached a plateau after a mean of 4 minutes at a constant infusion rate. Conclusion DSE can be easily performed in rats. The normal response is an increase in heart rate and ejection fraction and a decrease in LV dimensions. A plateau in echocardiographic measurements is obtained after 4 minutes of a constant infusion rate in most animals.

  20. Evaluation of Computer-Based Training for Health Workers in Echocardiography for RHD.

    Science.gov (United States)

    Engelman, Daniel; Okello, Emmy; Beaton, Andrea; Selnow, Gary; Remenyi, Bo; Watson, Caroline; Longenecker, Chris T; Sable, Craig; Steer, Andrew C

    2017-03-01

    The implementation of screening for rheumatic heart disease at a population-scale would require a considerable increase in human resources. Training nonexpert staff in echocardiography requires appropriate methods and materials. This pre/post study aims to measure the change in the knowledge and confidence of a group of health workers after a computer-assisted training intervention in basic echocardiography for rheumatic heart disease. A syllabus of self-guided, computer-based modules to train nonexpert health workers in basic echocardiography for rheumatic heart disease was developed. Thirty-eight health workers from Uganda participated in the training. Using a pre/post design, identical test instruments were administered before and after the training intervention, assessing the knowledge (using multiple-choice questions) and confidence (using Likert scale questions) in clinical science and echocardiography. The mean total score on knowledge tests rose from 44.8% to 85.4% (mean difference: 40.6%, 95% confidence interval [CI]: 35.4% to 45.8%), with strong evidence for an increase in scores across all knowledge theme areas (p science (difference: 7.1, 95% CI: 6.2 to 8.0; p computer-assisted learning may reduce the human resource requirements for training staff in echocardiography. Copyright © 2016 World Heart Federation (Geneva). Published by Elsevier B.V. All rights reserved.

  1. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  2. Comparison of dipyridamole-echocardiography with dipyridamole-thallium scintigraphy for the diagnosis of myocardial ischemia

    International Nuclear Information System (INIS)

    Perin, E.C.; Moore, W.; Blume, M.; Hernandez, G.; Dhekne, R.; DeCastro, C.M.

    1991-01-01

    After an intravenous infusion of dipyridamole (0.56 mg/kg), the authors performed both echocardiography and thallium scintigraphy in 63 patients who were referred for known or suspected coronary artery disease. Of those patients, 25 returned for coronary arteriography within 1 month after the tests, thus forming the study group for this report. Sensitivity for detection of coronary artery disease, when analyzed region-by-region, was 80% for thallium scintigraphy and 57% for echocardiography, whereas specificity was 85% and 98%, respectively. When evaluating individual patients for the presence or absence of ischemia, they found a sensitivity of 95% for scintigraphy and 58% for echocardiography; corresponding specificities were 50% and 100%. By using arteriography as the gold standard for comparison, it appears that thallium scintigraphy has a significantly higher sensitivity but lower specificity for the detection of coronary artery disease than does echocardiography. Echocardiography may, however, be a useful adjunct to thallium scintigraphy in the evaluation of patients with coronary artery disease

  3. Estimation of diastolic filling pressure with cardiac CT in comparison with echocardiography using tissue doppler imaging: Determination of optimal CT reconstruction parameters

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Sun; Suh, Jon; Lee, Heon [Soonchunhyang University Hospital Bucheon, Bucheon (Korea, Republic of); Lee, Bora [Dept. of Biostatistics, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of); Lee, Soo Jeong [Terarecon Korea, Seoul (Korea, Republic of); Jou, Sung Shick [Dept. of Radiology, Soonchunhyang University Hospital Cheonan, Cheonan (Korea, Republic of); Lim, Hyun Kyung [Dept. of Radiology, Soonchunhyang University Hospital Seoul, Seoul (Korea, Republic of)

    2017-08-01

    To determine the optimal CT image reconstruction parameters for the measurement of early transmitral peak velocity (E), early peak mitral septal tissue velocity (E′), and E / E′. Forty-six patients underwent simultaneous cardiac CT and echocardiography on the same day. Four CT datasets were reconstructed with a slice thickness/interval of 0.9/0.9 mm or 3/3 mm at 10 (10% RR-interval) or 20 (5% RR-interval) RR-intervals. The E was calculated by dividing the peak transmitral flow (mL/s) by the corresponding mitral valve area (cm{sup 2}). E′ was calculated from the changes in the left ventricular length per cardiac phase. E / E′ was then estimated and compared with that from echocardiography. For assessment of E / E′, CT and echocardiography were more strongly correlated (p < 0.05) with a slice thickness of 0.9 mm and 5% RR-interval (r = 0.77) than with 3 mm or 10% RR-interval. The diagnostic accuracy of predicting elevated filling pressure (E / E′ ≥ 13, n = 14) was better with a slice thickness of 0.9 mm and 5% RR-interval (87.0%) than with 0.9 mm and 10% RR-interval (71.7%) (p = 0.123) and significantly higher than that with a slice thickness of 3 mm with 5% (67.4%) and 10% RR-interval (63.0%), (p < 0.05), respectively. Data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval is superior to that with a slice thickness of 3 mm or 10% RR-interval in terms of the correlation of E / E′ between CT and echocardiography. Thin slices and frequent sampling also allow for more accurate prediction of elevated filling pressure.

  4. Two-Dimensional Echocardiography Estimates of Fetal Ventricular Mass throughout Gestation.

    Science.gov (United States)

    Aye, Christina Y L; Lewandowski, Adam James; Ohuma, Eric O; Upton, Ross; Packham, Alice; Kenworthy, Yvonne; Roseman, Fenella; Norris, Tess; Molloholli, Malid; Wanyonyi, Sikolia; Papageorghiou, Aris T; Leeson, Paul

    2017-08-12

    Two-dimensional (2D) ultrasound quality has improved in recent years. Quantification of cardiac dimensions is important to screen and monitor certain fetal conditions. We assessed the feasibility and reproducibility of fetal ventricular measures using 2D echocardiography, reported normal ranges in our cohort, and compared estimates to other modalities. Mass and end-diastolic volume were estimated by manual contouring in the four-chamber view using TomTec Image Arena 4.6 in end diastole. Nomograms were created from smoothed centiles of measures, constructed using fractional polynomials after log transformation. The results were compared to those of previous studies using other modalities. A total of 294 scans from 146 fetuses from 15+0 to 41+6 weeks of gestation were included. Seven percent of scans were unanalysable and intraobserver variability was good (intraclass correlation coefficients for left and right ventricular mass 0.97 [0.87-0.99] and 0.99 [0.95-1.0], respectively). Mass and volume increased exponentially, showing good agreement with 3D mass estimates up to 28 weeks of gestation, after which our measurements were in better agreement with neonatal cardiac magnetic resonance imaging. There was good agreement with 4D volume estimates for the left ventricle. Current state-of-the-art 2D echocardiography platforms provide accurate, feasible, and reproducible fetal ventricular measures across gestation, and in certain circumstances may be the modality of choice. © 2017 S. Karger AG, Basel.

  5. Noncontact 3-D Speckle Contrast Diffuse Correlation Tomography of Tissue Blood Flow Distribution.

    Science.gov (United States)

    Huang, Chong; Irwin, Daniel; Zhao, Mingjun; Shang, Yu; Agochukwu, Nneamaka; Wong, Lesley; Yu, Guoqiang

    2017-10-01

    Recent advancements in near-infrared diffuse correlation techniques and instrumentation have opened the path for versatile deep tissue microvasculature blood flow imaging systems. Despite this progress there remains a need for a completely noncontact, noninvasive device with high translatability from small/testing (animal) to large/target (human) subjects with trivial application on both. Accordingly, we discuss our newly developed setup which meets this demand, termed noncontact speckle contrast diffuse correlation tomography (nc_scDCT). The nc_scDCT provides fast, continuous, portable, noninvasive, and inexpensive acquisition of 3-D tomographic deep (up to 10 mm) tissue blood flow distributions with straightforward design and customization. The features presented include a finite-element-method implementation for incorporating complex tissue boundaries, fully noncontact hardware for avoiding tissue compression and interactions, rapid data collection with a diffuse speckle contrast method, reflectance-based design promoting experimental translation, extensibility to related techniques, and robust adjustable source and detector patterns and density for high resolution measurement with flexible regions of interest enabling unique application-specific setups. Validation is shown in the detection and characterization of both high and low contrasts in flow relative to the background using tissue phantoms with a pump-connected tube (high) and phantom spheres (low). Furthermore, in vivo validation of extracting spatiotemporal 3-D blood flow distributions and hyperemic response during forearm cuff occlusion is demonstrated. Finally, the success of instrument feasibility in clinical use is examined through the intraoperative imaging of mastectomy skin flap.

  6. Optimal time for predicting left ventricular remodeling after successful primary coronary angioplasty in acute myocardial infarction using serial myocardial contrast echocardiography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Sakuma, Tadamichi; Okada, Takenori; Hayashi, Yasuhiko; Otsuka, Masaya; Hirai, Yuukou

    2002-01-01

    The objective of this study was to determine the optimal time to assess microvascular integrity within the risk area for myocardial infarction in order to predict unfavorable left ventricular remodeling (LVR) after successful primary coronary angioplasty. Fifty-three patients who underwent myocardial contrast echocardiography (MCE) just before recanalization, shortly after and 1 day (Day 2) and 3 weeks after recanalization were studied. The no- and low-reflow ratio (LR ratio) was analyzed at each stage. The wall-tinning ratio within the risk area was determined using magnetic resonance imaging performed 3-4 weeks after the recanalization. Thirteen of the 53 patients showed LVR 3-8 months after recanalization. The optimal time to predict LVR was found to be Day 2 based on the receiver operating characteristic curves. The LR ratio on Day 2 (χ 2 =7.39, p=0.007) and the collateral circulation before recanalization (χ 2 =4.57, p=0.03) were chosen as independent variables for predicting LVR. Patients with greater than 0.43 in the LR ratio on Day 2 showed a lower wall-thinning ratio (58±19% vs 72±20%, p=0.05). This study shows that the optimal time to estimate the microvascular integrity for predicting LVR is 1 day after recanalization, which is neither shortly after recanalization nor during the convalescent stage. (author)

  7. Evaluation of right ventricular volume and function by 2D and 3D echocardiography compared to MRI

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Petersen, Claus Leth; Kjaer, Andreas

    2005-01-01

    : Thirty-four subjects with (a) prior inferior ST-elevation myocardial infarction (n=17), (b) a history of pulmonary embolism and persistent dyspnea (n=7) or (c) normal subjects (n=10) had 2D and 3D echocardiography, SPECT and MRI within 24h. End-diastolic volume and peak tricuspid regurgitation velocity...... were increased in patients with a history of pulmonary embolism compared to healthy subjects, 130+/-26 ml vs. 94+/-26 ml, P... volume showed significant correlation to RV volumes by MRI. Tricuspid annular plane systolic excursion (TAPSE) had the better correlation to RVEF by MRI, r=0.48, P

  8. Right ventricular volume determination by two-dimensional echocardiography and radiography in model hearts using a subtraction method

    International Nuclear Information System (INIS)

    Krebs, W.; Erbel, R.; Schweizer, P.; Richter, H.A.; Massberg, I.; Meyer, J.; Effert, S.; Henn, G.

    1982-01-01

    The irregularity and complexity of the right ventricle is the reason why no accurate method for right ventricular volume determination exists. A new method for right ventricular volume determination particularly for two-dimensional echocardiography was developed - it is called subtraction method - and was compared with the pyramid and Simpson's methods. The partial volume of the left ventricle and septum was subtracted from total volume of right and left ventricle including interventricular septum. Thus right ventricular volume resulted. Total and partial volume were computer-assisted calculated by use of biplane methods, preferably Simpson's rule. The method was proved with thinwall silicon-rubber model hearts of the left and right ventricle. Two orthogonal planes in the long-axis were filmed by radiography or scanned in a water bath by two-dimensional echocardiography equivalent to RAO and LAO-projections of cineangiocardiograms or to four- and two-chamber views of apical two-dimensional echocardiograms. For calculation of the major axes of the elliptical sections, summed up by Simpson's rule, they were derived from the LAO-projection and the four-chamber view, respectively, the minor axis approximated from the RAO-projection and the two-chamber view. For comparison of direct-measured volume and two-dimensional echocardiographically determined volume, regression equation was given by y = 1.01 x - 3.2, correlation-coefficient, r = 0.977, and standard error of estimate (SEE) +-10.5 ml. For radiography, regression equation was y = 0.909 x + 13.3, r = 0.983, SEE = +-8.0 ml. For pyramid method and Simpson's rule, higher standard errors and lower correlation coefficients were found. Between radiography and two-dimensional echocardiography a mean difference of 4.3 +- 13.2 ml, using subtraction method, and -10.2 +- 22.9 ml, using pyramid method, as well as -0.6 +- 18.5 ml, using Simpson's rule, were calculated for right ventricular volume measurements. (orig./APR) [de

  9. Audit of cardiac pathology detection using a criteria-based perioperative echocardiography service.

    Science.gov (United States)

    Faris, J G; Hartley, K; Fuller, C M; Langston, R B; Royse, C F; Veltman, M G

    2012-07-01

    Transthoracic echocardiography is often used to screen patients prior to non-cardiac surgery to detect conditions associated with perioperative haemodynamic compromise and to stratify risk. However, anaesthetists' use of echocardiography is quite variable. A consortium led by the American College of Cardiology Foundation has developed appropriate use criteria for echocardiography. At Joondalup Hospital in Western Australia, we have used these criteria to order echocardiographic studies in patients attending our anaesthetic pre-admission clinic. We undertook this audit to determine the incidence of significant echocardiographic findings using this approach. In a 22-month period, 606 transthoracic echocardiographic studies were performed. This represented 8.7% of clinic attendees and 1.7% of all surgical patients. In about two-thirds of the patients, the indication for echocardiography was identified on the basis of a telephone screening questionnaire. The most common indications were poor exercise tolerance (27.4%), ischaemic heart disease (20.9%) and cardiac murmurs (16.3%). Over 26% of patients studied had significant cardiac pathology (i.e. moderate or severe echocardiographic findings), most importantly moderate or severe aortic stenosis (8.6%), poor left ventricular function (7.1%), a regional wall motion abnormality (4.3%) or moderate or severe mitral regurgitation (4.1%). Using appropriate use criteria to guide ordering transthoracic echocardiography studies led to a high detection rate of clinically important cardiac pathology in our perioperative service.

  10. Comparison of two-dimensional echocardiography with gated radionuclide ventriculography in the evaluation of global and regional left ventricular function in acute myocardial infarction

    International Nuclear Information System (INIS)

    Van Reet, R.E.; Quinones, M.A.; Poliner, L.R.; Nelson, J.G.; Waggoner, A.D.; Kanon, D.; Lubetkin, S.J.; Pratt, C.M.; Winters, W.L. Jr.

    1984-01-01

    Two-dimensional echocardiography and gated radionuclide ventriculography were performed in 93 patients (66 men, 27 women; mean age 61 years) with 95 episodes of acute myocardial infarction within 48 hours and at 10 days after infarction. Abnormal motion of an inferior or posterior wall segment was seen in 91% of inferoposterior infarctions by echocardiography versus 61% seen by radionuclide ventriculography. Ejection fractions determined by echocardiography and radionuclide ventriculography correlated well (r . 0.82) and did not change from the first 48 hours to 10 days after infarction (0.48 +/- 0.14). Similarly, wall motion score showed minimal change from the first 48 hours to 10 days. In-hospital mortality was 37 and 42% in patients with an ejection fraction of 0.35 or less by echocardiography and radionuclide ventriculography, respectively. No mortality was seen in patients with an ejection fraction above 0.40 by either test. The echocardiographic wall motion score was also predictive of mortality (40 versus 2%; score less than or equal to 0.50 versus greater than 0.50). The 1 year mortality rate in the 81 short-term survivors was 17%. Mortality was lowest in patients with an ejection fraction above 0.49 or wall motion score above (0.79 (2 to 5%) and worse in those with an ejection fraction below 0.36 or wall motion score below 0.51 (36 to 63%) by either technique. Thus in acute myocardial infarction, echocardiography and radionuclide ventriculography provide a comparable assessment of left ventricular function and wall motion in anterior infarction. Echocardiography appears more sensitive in detecting inferoposterior wall motion abnormalities. Both techniques are capable of identifying subgroups of patients with a high risk of death during the acute event and with an equally high mortality rate over a 1 year follow-up period

  11. Dynamic 3D echocardiography in virtual reality.

    NARCIS (Netherlands)

    A.E. van den Bosch (Annemien); A.H.J. Koning (Anton); F.J. Meijboom (Folkert); J.S. Vletter-McGhie (Jackie); M.L. Simoons (Maarten); P.J. van der Spek (Peter); A.J.J.C. Bogers (Ad)

    2005-01-01

    textabstractBACKGROUND: This pilot study was performed to evaluate whether virtual reality is applicable for three-dimensional echocardiography and if three-dimensional echocardiographic 'holograms' have the potential to become a clinically useful tool. METHODS: Three-dimensional echocardiographic

  12. Echocardiography for patent ductus arteriosus including closure in adults.

    Science.gov (United States)

    Chugh, Reema; Salem, Morris M

    2015-01-01

    Patent ductus arteriosus (PDA) represents at least 5-10% of all congenital heart defects (CHDs) making it a very important commonly diagnosed lesion. Although spontaneous closure of the PDA occurs within 24 to 48 hours after birth in the majority, those children who do not have natural or surgical closure may have a persistent PDA into adulthood. The diagnosis is most often confirmed by echocardiography that also guides catheter-based interventions and surgeries. Echocardiography continues to be the most important tool in long-term follow-up of residua and sequelae. © 2014, Wiley Periodicals, Inc.

  13. Diffusion-weighted imaging and dynamic contrast-enhanced MRI of experimental breast cancer bone metastases – A correlation study with histology

    Energy Technology Data Exchange (ETDEWEB)

    Merz, Maximilian [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Department of Hematology, Oncology and Rheumatology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Seyler, Lisa; Bretschi, Maren; Semmler, Wolfhard [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Bäuerle, Tobias, E-mail: tobias.baeuerle@uk-erlangen.de [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Institute of Radiology, University Medical Center Erlangen, Palmsanlage 5, 90154 Erlangen (Germany)

    2015-04-15

    Purpose: To validate imaging parameters from diffusion-weighted imaging and dynamic contrast-enhanced MRI with immunohistology and to non-invasively assess microstructure of experimental breast cancer bone metastases. Materials and methods: Animals bearing breast cancer bone metastases were imaged in a clinical 1.5 T MRI scanner. HASTE sequences were performed to calculate apparent diffusion coefficients. Saturation recovery turbo FLASH sequences were conducted while infusing 0.1 mmol/l Gd–DTPA for dynamic contrast-enhanced MRI to quantify parameters amplitude A and exchange rate constant k{sub ep}. After imaging, bone metastases were analyzed immunohistologically. Results: We found correlations of the apparent diffusion coefficients from diffusion-weighted imaging with tumor cellularity as assessed with cell nuclei staining. Histological vessel maturity was correlated negatively with parameters A and k{sub ep} from dynamic contrast-enhanced MRI. Tumor size correlated inversely with cell density and vessel permeability as well as positively with mean vessel calibers. Parameters from the rim of bone metastases differed significantly from values of the center. Conclusion: In vivo diffusion-weighted imaging and dynamic contrast-enhanced MRI in experimental bone metastases provide information about tumor cellularity and vascularity and correlate well with immunohistology.

  14. Can M mode and two dimensional echocardiography give a sufficient evaluation for surgeray of patients with pure mitral stenosis

    International Nuclear Information System (INIS)

    Balbarini, A; Tartarini, G.; Mengozzi, G.; Mariani, M.; Salvatore, L.; Barsotti, A.

    1987-01-01

    One hundred and twenty-six patients with rheumatic mitral stenosis were studied by M-mode and/or two-dimensional echocardiography. Eighty-nine patients were also submetted to cardiac catheterization and all 126 patients subsequently underwent mitral valve surgery (51 valvulotomy and 75 valve replacement). The mitral valve area measured by two-dimensional echocardiography showed a significant correlation both with hemodynamic (r=0.803, p 2 , respectively; likewise there was non significant difference in pulmonary vascular resistances (3.9 and 3.4 mmHg/l/min/m 2 ) between patients who showed functional improvement after surgery comparison to those who showed no improvement. Finally, coronary arteriography appeared to be necessary, before operation, only in cardiography is able to provide a satisfactory preoperative assessment of patients with mitral stenosis and that therefore these patients need not necessarily to be submitted to cardiac catheterization

  15. Comparison of exercise stress testing with dobutamine stress echocardiography and radionuclide ventriculography for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Ozdemir, K.; Kisacik, H.L.; Oguzhan, A.

    1999-01-01

    Dobutamine stress echocardiography, Tc-99m radionuclide ventriculography (RNVG), and exercise stress testing were performed prospectively in 63 patients with suspected coronary artery disease to compare the values of exercise testing, dobutamine stress echocardiography and RNVG in the non-invasive diagnosis of coronary artery disease. The sensitivities of dobutamine stress echocardiography and RNVG were found to be higher than that of exercise testing (93-62%, p 0.05). There were no differences between the sensitivities of the three techniques in multiple vessel disease (p>0.05). The specificities of dobutamine stress echocardiography and RNVG were higher than that of exercise testing (for both of the tests 86-62%, p 0.05). The results of dobutamine stress echocardiography RNVG were concordant with each other in 46 patients (76%, kappa=65%) in sectional analysis. Dobutamine stress echocardiography and RNVG tests were comparable with each other in 85% of the 189 segments (kappa=64%). The expected 5% decrease at peak doses of dobutamine was not detected in stress echocardiography in 25 patients and in RNVG in 26 of the patients. Dobutamine stress echocardiography and RNVG are superior to exercise testing in the diagnosis of single vessel disease and there is no significant difference between the two techniques. When the ejection fraction is considered in dobutamine stress echocardiography and RNVG, it does not make an additional contribution to the diagnosis of coronary artery disease. (author)

  16. Apparent Diffusion Coefficient and Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Pancreatic Cancer: Characteristics and Correlation With Histopathologic Parameters.

    Science.gov (United States)

    Ma, Wanling; Li, Na; Zhao, Weiwei; Ren, Jing; Wei, Mengqi; Yang, Yong; Wang, Yingmei; Fu, Xin; Zhang, Zhuoli; Larson, Andrew C; Huan, Yi

    2016-01-01

    To clarify diffusion and perfusion abnormalities and evaluate correlation between apparent diffusion coefficient (ADC), MR perfusion and histopathologic parameters of pancreatic cancer (PC). Eighteen patients with PC underwent diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Parameters of DCE-MRI and ADC of cancer and non-cancerous tissue were compared. Correlation between the rate constant that represents transfer of contrast agent from the arterial blood into the extravascular extracellular space (K, volume of the extravascular extracellular space per unit volume of tissue (Ve), and ADC of PC and histopathologic parameters were analyzed. The rate constant that represents transfer of contrast agent from the extravascular extracellular space into blood plasma, K, tissue volume fraction occupied by vascular space, and ADC of PC were significantly lower than nontumoral pancreases. Ve of PC was significantly higher than that of nontumoral pancreas. Apparent diffusion coefficient and K values of PC were negatively correlated to fibrosis content and fibroblast activation protein staining score. Fibrosis content was positively correlated to Ve. Apparent diffusion coefficient values and parameters of DCE-MRI can differentiate PC from nontumoral pancreases. There are correlations between ADC, K, Ve, and fibrosis content of PC. Fibroblast activation protein staining score of PC is negatively correlated to ADC and K. Apparent diffusion coefficient, K, and Ve may be feasible to predict prognosis of PC.

  17. The Interplay between Fasting Glucose, Echocardiography, and Biomarkers

    DEFF Research Database (Denmark)

    Pareek, Manan

    preventive setting, remains incomplete. Phenotypical heterogeneity may be even greater among subjects with hyperglycemic conditions, i.e., prediabetes and diabetes, which is worrisome, given the dramatic global rise in mean fasting glucose levels, and the strong association with adverse cardiovascular...... subclinical changes to manifest disease include echocardiography and circulating biomarkers. Objectives 1) To examine whether greater fasting plasma glucose (FPG) levels were associated with left ventricular mass (LVM), geometric pattern, diastolic function, and concentrations of N-terminal prohormone...... from the three categories defined by baseline FPG, i.e., normal fasting glucose, impaired fasting glucose, and diabetes, including use of anti-diabetic medication. Blood samples for cardiovascular biomarker assessments were drawn at the time of echocardiography and kept frozen until analysis. Outcome...

  18. Evaluation of left ventricular volumes in patients with congenital heart disease and abnormal left ventricular geometry. Comparison of MRI and transthoracic 3-dimensional echocardiography

    International Nuclear Information System (INIS)

    Gutberlet, M.; Grothoff, M.; Roettgen, R.; Lange, P.; Felix, R.; Abdul-Khaliq, H.; Schroeter, J.; Schmitt, B.; Vogel, M.

    2003-01-01

    Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8±9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec trademark (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only succeeded in 11 to 18 patients (61%) due to inadequate visualization of the entire myocardium. Comparing MRI and 3D-echocardiography, the correlation was r=0.97 for the end-systolic volumes, r=0.98 for the end-diastolic volumes, r=0.79 for the end-systolic muscle mass and r=0.77 for the end-diastolic muscle mass. The agreement between both methods was considered good for the calculated end-diastolic volumes and sufficient for the calculated end-systolic volumes. The muscle mass calculations showed larger differences especially for the end-systolic mass. Mean intraobserver variability was 18.6% for end-systolic and 8.3% for end-diastolic volumes. Conclusion: In patients with an abnormal left ventricular configuration due to congenital heart disease, the new method of 3D-echocardiography is sufficient for volume calculations in preselected patients. The high intraobserver variability is still a limitation of transthoracic 3D-echocardiography in comparison to MRI. (orig.) [de

  19. Comparison of transcoelomic, contrast transcoelomic, and transesophageal echocardiography in anesthetized red-tailed hawks (Buteo jamaicensis).

    Science.gov (United States)

    Beaufrère, Hugues; Pariaut, Romain; Rodriguez, Daniel; Nevarez, Javier G; Tully, Thomas N

    2012-10-01

    To assess the agreement and reliability of cardiac measurements obtained with 3 echocardiographic techniques in anesthetized red-tailed hawks (Buteo jamaicensis). 10 red-tailed hawks. Transcoelomic, contrast transcoelomic, and transesophageal echocardiographic evaluations of the hawks were performed, and cineloops of imaging planes were recorded. Three observers performed echocardiographic measurements of cardiac variables 3 times on 3 days. The order in which hawks were assessed and echocardiographic techniques were used was randomized. Results were analyzed with linear mixed modeling, agreement was assessed with intraclass correlation coefficients, and variation was estimated with coefficients of variation. Significant differences were evident among the 3 echocardiographic methods for most measurements, and the agreement among findings was generally low. Interobserver agreement was generally low to medium. Intraobserver agreement was generally medium to high. Overall, better agreement was achieved for the left ventricular measurements and for the transesophageal approach than for other measurements and techniques. Echocardiographic measurements in hawks were not reliable, except when the left ventricle was measured by the same observer. Furthermore, cardiac morphometric measurements may not be clinically important. When measurements are required, one needs to consider that follow-up measurements should be performed by the same echocardiographer and should show at least a 20% difference from initial measurements to be confident that any difference is genuine.

  20. Usefulness of three-dimensional echocardiography in the assessment of valvular involvement in Loeffler endocarditis.

    Science.gov (United States)

    Hernandez, Carlos M; Arisha, Mohammed J; Ahmad, Amier; Oates, Ethan; Nanda, Navin C; Nanda, Anil; Wasan, Anita; Caleti, Beda E; Bernal, Cinthia L P; Gallardo, Sergio M

    2017-07-01

    Loeffler endocarditis is a complication of hypereosinophilic syndrome resulting from eosinophilic infiltration of heart tissue. We report a case of Loeffler endocarditis in which three-dimensional transthoracic and transesophageal echocardiography provided additional information to what was found by two-dimensional transthoracic echocardiography alone. Our case illustrates the usefulness of combined two- and three-dimensional echocardiography in the assessment of Loeffler endocarditis. In addition, a summary of the features of hypereosinophilic syndrome and Loeffler endocarditis is provided in tabular form. © 2017, Wiley Periodicals, Inc.

  1. Quantification of global myocardial function by cine MRI deformable registration-based analysis: Comparison with MR feature tracking and speckle-tracking echocardiography.

    Science.gov (United States)

    Lamacie, Mariana M; Thavendiranathan, Paaladinesh; Hanneman, Kate; Greiser, Andreas; Jolly, Marie-Pierre; Ward, Richard; Wintersperger, Bernd J

    2017-04-01

    To evaluate deformable registration algorithms (DRA)-based quantification of cine steady-state free-precession (SSFP) for myocardial strain assessment in comparison with feature-tracking (FT) and speckle-tracking echocardiography (STE). Data sets of 28 patients/10 volunteers, undergoing same-day 1.5T cardiac MRI and echocardiography were included. LV global longitudinal (GLS), circumferential (GCS) and radial (GRS) peak systolic strain were assessed on cine SSFP data using commercially available FT algorithms and prototype DRA-based algorithms. STE was applied as standard of reference for accuracy, precision and intra-/interobserver reproducibility testing. DRA showed narrower limits of agreement compared to STE for GLS (-4.0 [-0.9,-7.9]) and GCS (-5.1 [1.1,-11.2]) than FT (3.2 [11.2,-4.9]; 3.8 [13.9,-6.3], respectively). While both DRA and FT demonstrated significant differences to STE for GLS and GCS (all pcine MRI. • Inverse DRA demonstrated superior reproducibility compared to feature-tracking (FT) methods. • Cine MR DRA and FT analysis demonstrate differences to speckle-tracking echocardiography • DRA demonstrated better correlation with STE than FT for MR-derived global strain data.

  2. Acute right ventricular dysfunction: real-time management with echocardiography.

    Science.gov (United States)

    Krishnan, Sundar; Schmidt, Gregory A

    2015-03-01

    In critically ill patients, the right ventricle is susceptible to dysfunction due to increased afterload, decreased contractility, or alterations in preload. With the increased use of point-of-care ultrasonography and a decline in the use of pulmonary artery catheters, echocardiography can be the ideal tool for evaluation and to guide hemodynamic and respiratory therapy. We review the epidemiology of right ventricular failure in critically ill patients; echocardiographic parameters for evaluating the right ventricle; and the impact of mechanical ventilation, fluid therapy, and vasoactive infusions on the right ventricle. Finally, we summarize the principles of management in the context of right ventricular dysfunction and provide recommendations for echocardiography-guided management.

  3. Correlation between dynamic contrast-enhanced MRI and quantitative histopathologic microvascular parameters in organ-confined prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Niekerk, Cornelis G. van; Laak, Jeroen A.W.M. van der; Kaa, Christina A.H. de [Radboud University Medical Centre, Department of Pathology, P.O. Box 9101, Nijmegen (Netherlands); Hambrock, Thomas; Huisman, Henk-Jan; Barentsz, Jelle O. [Radboud University Medical Centre, Department of Radiology, Nijmegen (Netherlands); Witjes, J.A. [Radboud University Medical Centre, Department of Urology, Nijmegen (Netherlands)

    2014-10-15

    To correlate pharmacokinetic parameters of 3-T dynamic contrast-enhanced (DCE-)MRI with histopathologic microvascular and lymphatic parameters in organ-confined prostate cancer. In 18 patients with unilateral peripheral zone (pT2a) tumours who underwent DCE-MRI prior to radical prostatectomy (RP), the following pharmacokinetic parameters were assessed: permeability surface area volume transfer constant (K{sup trans}), extravascular extracellular volume (Ve) and rate constant (K{sub ep}). In the RP sections blood and lymph vessels were visualised immunohistochemically and automatically examined and analysed. Parameters assessed included microvessel density (MVD), area (MVA) and perimeter (MVP) as well as lymph vessel density (LVD), area (LVA) and perimeter (LVP). A negative correlation was found between age and K{sup trans} and K{sub ep} for tumour (r = -0.60, p = 0.009; r = -0.67, p = 0.002) and normal (r = -0.54, p = 0.021; r = -0.46, p = 0.055) tissue. No correlation existed between absolute values of microvascular parameters from histopathology and DCE-MRI. In contrast, the ratio between tumour and normal tissue (correcting for individual microvascularity variations) significantly correlated between K{sub ep} and MVD (r = 0.61, p = 0.007) and MVP (r = 0.54, p = 0.022). The lymphovascular parameters showed only a correlation between LVA and K{sub ep} (r = -0.66, p = 0.003). Significant correlations between DCE-MRI and histopathologic parameters were found when correcting for interpatient variations in microvascularity. (orig.)

  4. Student tutors for hands-on training in focused emergency echocardiography – a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Kühl Matthias

    2012-10-01

    Full Text Available Abstract Background Focused emergency echocardiography performed by non-cardiologists has been shown to be feasible and effective in emergency situations. During resuscitation a short focused emergency echocardiography has been shown to narrow down potential differential diagnoses and to improve patient survival. Quite a large proportion of physicians are eligible to learn focused emergency echocardiography. Training in focused emergency echocardiography usually comprises a lecture, hands-on trainings in very small groups, and a practice phase. There is a shortage of experienced echocardiographers who can supervise the second step, the hands-on training. We thus investigated whether student tutors can perform the hands-on training for focused emergency echocardiography. Methods A total of 30 volunteer 4th and 5th year students were randomly assigned to a twelve-hour basic echocardiography course comprising a lecture followed by a hands-on training in small groups taught either by an expert cardiographer (EC or by a student tutor (ST. Using a pre-post-design, the students were evaluated by an OSCE. The students had to generate two still frames with the apical five-chamber view and the parasternal long axis in five minutes and to correctly mark twelve anatomical cardiac structures. Two blinded expert cardiographers rated the students’ performance using a standardized checklist. Students could achieve a maximum of 25 points. Results Both groups showed significant improvement after the training (p Conclusions Hands-on training by student tutors led to a significant gain in echocardiography skills, although inferior to teaching by an expert cardiographer.

  5. Evaluation of Left Ventricular Diastolic Dysfunction with Early Systolic Dysfunction Using Two-Dimensional Speckle Tracking Echocardiography in Canine Heart Failure Model.

    Science.gov (United States)

    Wu, Wei-Chun; Ma, Hong; Xie, Rong-Ai; Gao, Li-Jian; Tang, Yue; Wang, Hao

    2016-04-01

    This study evaluated the role of two-dimensional speckle tracking echocardiography (2DSTE) for predicting left ventricular (LV) diastolic dysfunction in pacing-induced canine heart failure. Pacing systems were implanted in 8 adult mongrel dogs, and continuous rapid right ventricular pacing (RVP, 240 beats/min) was maintained for 2 weeks. The obtained measurements from 2DSTE included global strain rate during early diastole (SRe) and during late diastole (SRa) in the longitudinal (L-SRe, L-SRa), circumferential (C-SRe, C-SRa), and radial directions (R-SRe, R-SRa). Changes in heart morphology were observed by light microscopy and transmission electron microscopy at 2 weeks. The onset of LV diastolic dysfunction with early systolic dysfunction occurred 3 days after RVP initiation. Most of the strain rate imaging indices were altered at 1 or 3 days after RVP onset and continued to worsen until heart failure developed. Light and transmission electron microscopy showed myocardial vacuolar degeneration and mitochondrial swelling in the left ventricular at 2 weeks after RVP onset. Pearson's correlation analysis revealed that parameters of conventional echocardiography and 2DSTE showed moderate correlation with LV pressure parameters, including E/Esep' (r = 0.58, P echocardiography and strain rate imaging could effectively predict LV diastolic dysfunction (area under the curve: E/Esep' 0.78; L-SRe 0.84; E/L-SRe 0.80; R-SRe 0.80). 2DSTE was a sensitive and accurate technique that could be used for predicting LV diastolic dysfunction in canine heart failure model. © 2015, Wiley Periodicals, Inc.

  6. Correlation between blood and lymphatic vessel density and results of contrast-enhanced spectral mammography.

    Science.gov (United States)

    Luczynska, Elzbieta; Niemiec, Joanna; Ambicka, Aleksandra; Adamczyk, Agnieszka; Walasek, Tomasz; Ryś, Janusz; Sas-Korczyńska, Beata

    2015-09-01

    Contrast-enhanced spectral mammography (CESM) is a novel technique used for detection of tumour vascularity by imaging the moment in which contrast, delivered to the lesion by blood vessels, leaks out of them, and flows out through lymphatic vessels. In our study, we included 174 women for whom spectral mammography was performed for diagnostic purposes. The relationship between enhancement in CESM and blood vessel density (BVD), lymphatic vessel density (LVD) or the percentage of fields with at least one lymphatic vessel (distribution of podoplanin-positive vessels - DPV) and other related parameters was assessed in 55 cases. BVD, LVD and DPV were assessed immunohistochemically, applying podoplanin and CD31/CD34 as markers of lymphatic and blood vessels, respectively. The sensitivity (in detection of malignant lesions) of CESM was 100%, while its specificity - 39%. We found a significant positive correlation between the intensity of enhancement in CESM and BVD (p = 0.007, r = 0.357) and a negative correlation between the intensity of enhancement in CESM and DPV (p = 0.003, r = -0.390). Lesions with the highest enhancement in CESM showed a high number of blood vessels and a low number of lymphatics. 1) CESM is a method characterized by high sensitivity and acceptable specificity; 2) the correlation between CESM results and blood/lymphatic vessel density confirms its utility in detection of tissue angiogenesis and/or lymphangiogenesis.

  7. Contrast-enhanced dynamic magnetic resonance imaging findings of hepatocellular carcinoma and their correlation with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Karahan, Okkes I. [Department of Radiology, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey)]. E-mail: oikarahan@yahoo.com; Yikilmaz, Ali [Department of Radiology, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey); Artis, Tarik [Department of General Surgery, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey); Canoz, Ozlem [Department of Pathology, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey); Coskun, Abdulhakim [Department of Radiology, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey); Torun, Edip [Department of Internal Medicine, Division of Gastrenterology, Erciyes University Medical Faculty, PK: 18 Talas 38280, Kayseri (Turkey)

    2006-03-15

    Purpose: To investigate the correlations of contrast-enhanced magnetic resonance (MR) imaging findings of large (>5 cm) hepatocellular carcinomas with tumor size and histopathologic findings. Materials and methods: MR imaging was performed in 30 patients with a histopathologic diagnosis of hepatocellular carcinoma. The imaging protocol included non-contrast, hepatic arterial, portal venous and late phases. The signal intensities relative to the liver, enhancement patterns and the morphologic features of the lesions were evaluated in relation to size and degree of differentiation. Results: On histopathologic examination, 12 of 30 (40%) tumors were well-differentiated (grade 1), 6 of 30 (20%) were moderately differentiated (grades 2 and 3) and 12 of 30 (40%) were poorly differentiated (grade 4). Tumor size, tumor boundary, serum alpha-fetoprotein level and portal vein invasion were found to have statistically significant correlations with the degree of differentiation (p < 0.05). Portal vein invasion, capsule formation and tumor surface characteristics showed statistically significant correlations with tumor size (p < 0.05). Conclusion: MR imaging findings of hepatocellular carcinomas larger than 5 cm are partially dependent on tumor size and degree of differentiation.

  8. An investigation into the causes of unexpected intra-operative transoesophageal echocardiography findings.

    Science.gov (United States)

    Skinner, H J; Mahmoud, A; Uddin, A; Mathew, T

    2012-04-01

    There is uncertainty regarding echocardiography before cardiac surgery, especially with regard to timing and disease progression as well as potential errors. We investigated the causes of unexpected intra-operative transoesophageal echocardiography findings by performing a 33-month audit. We found that there were 50/797 (6%) unexpected findings that led to an alteration in surgical strategy in 34 (4%) patients. Of the unexpected findings, 25 (50%) were unrelated to pre-operative pathology. After reviewing pre-operative studies and reports, unexpected findings were found to be due to: reporting errors in 20 patients (44%); limitations in transthoracic compared to transoesophageal echocardiography in 14 patients (30%); disease progression in 10 patients (22%); and inter-observer variability in two patients (4%). We identified six reports out of 797 (0.8%) that contained potentially serious errors. Surgical management changed in 18/20 (90%) patients in whom the unexpected change was due to reporting error, compared to 16/30 (53%) patients whose pre-operative echocardiogram was correctly reported (p = 0.006). Our study suggests that pre-operative echocardiography reporting errors are common and important. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.

  9. The Role of Stress Echocardiography in Valvular Heart Disease: A Current Appraisal.

    Science.gov (United States)

    Gentry Iii, James L; Phelan, Dermot; Desai, Milind Y; Griffin, Brian P

    Stress echocardiography is a widely available, safe, low-cost, versatile imaging modality which is becoming increasingly recognized as a valuable tool in the assessment of patients with native and prosthetic left-sided valvular heart disease. It provides a quantitative assessment to help guide clinical decision-making when discordance exists between symptoms and severity of valve disease. Exercise (treadmill or bicycle) remains the preferred stress modality, but pharmacological augmentation with dobutamine can be used if needed. Low-dose dobutamine stress echocardiography is specifically valuable in patients with low-flow, low-gradient aortic stenosis when attempting to differentiate true severe aortic stenosis from pseudo-severe aortic stenosis. Stress echocardiography not only identifies high-risk features that indicate need for earlier surgery, it also provides useful information for the peri- and postoperative period, including long-term outcome, risk stratification to guide monitoring frequency, and offers guidance for eligibility in competitive sports participation. As research continues to expand the utility of stress echocardiography in the management of patients with valvular heart disease, future research should focus on the recognition of newer parameters identifying high-risk features including subsequent validation in a large population. © 2017 S. Karger AG, Basel.

  10. Results of a Prospective Echocardiography Trial in International Space Station Crew

    Science.gov (United States)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Martin, David; Garcia, Kathleen M.; Melton, Shannon; Feiverson, Alan; Dulchavsky, Scott A.

    2009-01-01

    In the framework of an operationally oriented investigation, we conducted a prospective trial of a standard clinical echocardiography protocol in a cohort of long-duration crewmembers. The resulting primary and processed data appear to have no precedents. Our tele-echocardiography paradigm, including just-in-time e-training methods, was also assessed. A critical review of the imaging technique, equipment and setting limitations, and quality assurance is provided, as well as the analysis of "space normal" data.

  11. Improved motion contrast and processing efficiency in OCT angiography using complex-correlation algorithm

    International Nuclear Information System (INIS)

    Guo, Li; Li, Pei; Pan, Cong; Cheng, Yuxuan; Ding, Zhihua; Li, Peng; Liao, Rujia; Hu, Weiwei; Chen, Zhong

    2016-01-01

    The complex-based OCT angiography (Angio-OCT) offers high motion contrast by combining both the intensity and phase information. However, due to involuntary bulk tissue motions, complex-valued OCT raw data are processed sequentially with different algorithms for correcting bulk image shifts (BISs), compensating global phase fluctuations (GPFs) and extracting flow signals. Such a complicated procedure results in massive computational load. To mitigate such a problem, in this work, we present an inter-frame complex-correlation (CC) algorithm. The CC algorithm is suitable for parallel processing of both flow signal extraction and BIS correction, and it does not need GPF compensation. This method provides high processing efficiency and shows superiority in motion contrast. The feasibility and performance of the proposed CC algorithm is demonstrated using both flow phantom and live animal experiments. (paper)

  12. Intracardiac echocardiography: use during transcatheter device closure of a patent ductus arteriosus in a dog.

    Science.gov (United States)

    Chetboul, V; Damoiseaux, C; Behr, L; Morlet, A; Moise, N S; Gouni, V; Lavennes, M; Pouchelon, J-L; Laborde, F; Borenstein, N

    2017-06-01

    Intracardiac echocardiography (ICE) is used in humans for percutaneous interventional procedures, such as transcatheter device closures. Intracardiac echocardiography provides high-resolution imaging of cardiac structures with two-dimensional, M-mode, Doppler, and also three-dimensional modalities. The present report describes application of ICE during transcatheter occlusion of patent ductus arteriosus using a canine ductal occluder in a dog for which transesophageal echocardiography could not provide an optimal acoustic window. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Ileal Crohn disease: mural microvascularity quantified with contrast-enhanced US correlates with disease activity.

    Science.gov (United States)

    De Franco, Antonio; Di Veronica, Alessandra; Armuzzi, Alessandro; Roberto, Italia; Marzo, Manuela; De Pascalis, Barbara; De Vitis, Italo; Papa, Alfredo; Bock, Enrico; Danza, Francesco M; Bonomo, Lorenzo; Guidi, Luisa

    2012-02-01

    To quantitatively assess microvascular activation in the thickened ileal walls of patients with Crohn disease (CD) by using contrast-enhanced ultrasonography (US) and evaluate its correlation with widely used indexes of CD activity. This prospective study was approved by the ethics committee, and written informed consent was obtained from all patients. The authors examined 54 consecutively enrolled patients (mean age, 35.29 years; age range, 18-69 years; 39 men, 15 women) with endoscopically confirmed CD of the terminal ileum. Ileal wall segments thicker than 3 mm were examined with low-mechanical-index contrast-enhanced US and a second-generation US contrast agent. The authors analyzed software-plotted time-enhancement intensity curves to determine the maximum peak intensity (MPI) and wash-in slope coefficient (β) and evaluated their correlation with (a) the composite index of CD activity (CICDA), (b) the CD activity index (CDAI), and (c) the simplified endoscopic score for CD (SES-CD, evaluated in 37 patients) for the terminal ileum. Statistical analysis was performed with the Mann-Whitney test, Spearman rank test, and receiver operating characteristic (ROC) analysis. MPI and β coefficients were significantly increased in the 36 patients with a CICDA indicative of active disease (P<.0001 for both), the 33 patients with a CDAI of at least 150 (P<.032 and P<.0074, respectively), and the 26 patients with an SES-CD of at least 1 (P<.0001 and P<.002, respectively). ROC analysis revealed accurate identification (compared with CICDA) of active CD with an MPI threshold of 24 video intensity (VI) (sensitivity, 97%; specificity, 83%) and a β coefficient of 4.5 VI/sec (sensitivity, 86%; specificity, 83%). Contrast-enhanced US of the ileal wall is a promising method for objective, reproducible assessment of disease activity in patients with ileal CD. © RSNA, 2011

  14. Association of heart failure hospitalizations with combined electrocardiography and echocardiography criteria for left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Gerdts, Eva; Okin, Peter M; Boman, Kurt

    2012-01-01

    The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain.......The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain....

  15. Assessment of Myocardial Ischemia in Obese Individuals Undergoing Physical Stress Echocardiography (PSE

    Directory of Open Access Journals (Sweden)

    Mara Graziele Maciel Silveira

    2015-05-01

    Full Text Available Background: Physical stress echocardiography is an established methodology for diagnosis and risk stratification of coronary artery disease in patients with physical capacity. In obese (body mass index ≥ 30 kg/m2 the usefulness of pharmacological stress echocardiography has been demonstrated; however, has not been reported the use of physical stress echocardiography in this growing population group. Objective: To assess the frequency of myocardial ischemia in obese and non-obese patients undergoing physical stress echocardiography and compare their clinical and echocardiographic differences. Methods: 4,050 patients who underwent treadmill physical stress echocardiography were studied according to the Bruce protocol, divided into two groups: obese (n = 945; 23.3% and non-obese (n = 3,105; 76.6%. Results: There was no difference regarding gender. Obese patients were younger (55.4 ± 10.9 vs. 57.56 ± 11.67 and had a higher frequency of hypertension (75.2% vs. 57, 2%; p < 0.0001, diabetis mellitus (15.2% vs. 10.9%; p < 0.0001, dyslipidemia (59.5% vs 51.9%; p < 0.0001, family history of coronary artery disease (59.3% vs. 55.1%; p = 0.023 and physical inactivity (71.4% vs. 52.9%, p < 0.0001. The obese had greater aortic dimensions (3.27 vs. 3.14 cm; p < 0.0001, left atrium (3.97 vs. 3.72 cm; p < 0.0001 and the relative thickness of the ventricule (33.7 vs. 32.8 cm; p < 0.0001. Regarding the presence of myocardial ischemia, there was no difference between groups (19% vs. 17.9%; p = 0.41. In adjusted logistic regression, the presence of myocardial ischemia remained independently associated with age, female gender, diabetes and hypertension. Conclusion: Obesity did not behave as a predictor of the presence of ischemia and the physical stress echocardiography. The application of this assessment tool in large scale sample demonstrates the feasibility of the methodology, also in obese.

  16. Avoiding transthoracic echocardiography and transesophageal echocardiography for patients with variable body mass indexes in infective endocarditis

    Directory of Open Access Journals (Sweden)

    Robert Sogomonian

    2016-04-01

    Full Text Available Background: Echocardiography has been a popular modality used to aid in the diagnosis of infective endocarditis (IE with the modified Duke criteria. We evaluated the necessity between the uses of either a transthoracic echocardiography (TTE or transesophageal echocardiography (TEE in patients with a body mass index (BMI greater than or equal to 25 kg/m2 and less than 25 kg/m2. Methods: A single-centered, retrospective study of 198 patients between 2005 and 2012 diagnosed with IE based on modified Duke criteria. Patients, required to be above age 18, had undergone an echocardiogram study and had blood cultures to be included in the study. Results: Among 198 patients, two echocardiographic groups were evaluated as 158 patients obtained a TTE, 143 obtained a TEE, and 103 overlapped with TEE and TTE. Out of these patients, 167 patients were included in the study as 109 (65% were discovered to have native valve vegetations on TEE and 58 (35% with TTE. TTE findings were compared with TEE results for true negatives and positives to isolate valvular vegetations. Overall sensitivity of TTE was calculated to be 67% with a specificity of 93%. Patients were further divided into two groups with the first group having a BMI ≥25 kg/m2 and the subsequent group with a BMI <25 kg/m2. Patients with a BMI ≥25 kg/m2 who underwent a TTE study had a sensitivity and specificity of 54 and 92%, respectively. On the contrary, patients with a BMI < 25 kg/m2 had a TTE sensitivity and specificity of 78 and 95%, respectively. Conclusions: Patients with a BMI <25 kg/m2 and a negative TTE should refrain from further diagnostic studies, with TEE strong clinical judgment is warranted. Patients with a BMI ≥ 25 kg/m2 may proceed directly to TEE as the initial study, possibly avoiding an additional study with a TTE.

  17. Assessment of left atrial appendage function by transthoracic pulsed Doppler echocardiography: Comparing against transesophageal interrogation and predicting echocardiographic risk factors for stroke.

    Science.gov (United States)

    Wai, Shin Hnin; Kyu, Kyu; Galupo, Mary Joyce; Songco, Geronica G; Kong, William K F; Lee, Chi Hang; Yeo, Tiong Cheng; Poh, Kian Keong

    2017-10-01

    Transesophageal echocardiographic (TEE) findings of left atrial appendage (LAA) thrombus, spontaneous echo contrast (SEC), and LAA dysfunction are established risk factors of cardioembolic stroke. The semi-invasive nature of TEE limits its utility as a routine risk stratification tool. We aim to correlate TEE and transthoracic echocardiography (TTE) pulsed Doppler measurements of LAA flow velocities and use TTE measurements to predict TEE findings. We prospectively measured pulsed Doppler LAA flow velocities in 103 consecutive patients on TEE and TTE. There was a strong correlation between TEE and TTE LAA emptying velocity (LAA E) (r = .88, P < .001) and a moderate correlation between LAA filling velocities (r = .50, P < .001). TTE LAA E predicted the presence of thrombus or SEC independent of atrial fibrillation (AF). To predict the presence of thrombus or SEC, the optimal TTE LAA E cutoff was ≤30 cm/s in all patients (75% sensitive, 90% specific) and ≤31 cm/s in AF patients (80% sensitive, 79% specific). To predict LAA dysfunction (TEE E ≤ 20 cm/s), the optimal TTE LAA E cutoff was ≤27 cm/s (100% sensitive, 89% specific in all patients and 100% sensitive, 74% specific in AF patients). TTE assessment of LAA function is feasible and correlates well with the more invasive TEE method. It predicts the presence of thrombus, SEC, and LAA dysfunction on TEE. TTE LAA assessment has incremental value in thromboembolic risk stratification and should be utilized more frequently. © 2017, Wiley Periodicals, Inc.

  18. Predictive role of stress echocardiography before carotid endarterectomy in patients with coronary artery disease.

    Science.gov (United States)

    Galyfos, George; Tsioufis, Constantinos; Theodorou, Dimitris; Katsaragakis, Stilianos; Zografos, Georgios; Filis, Konstantinos

    2015-07-01

    Our aim was to examine the predictive value of preoperative stress echocardiography regarding early myocardial ischemia and late cardiac events after carotid endarterectomy (CEA). Patients with coronary artery disease undergoing CEA were prospectively included in this study. All patients (n = 162) were classified into low, medium, and high cardiac risk group, according to preoperative stress echocardiography. Classification was based on the criteria of the American Society of Echocardiography. For all patients, cTnI was measured before surgery and on postoperative days 1, 3, and 7. Postoperative cTnI values ranging from 0.05 to 0.5 ng/mL were classified as myocardial ischemia; values >0.5 ng/mL were classified as myocardial infarction. Cardiac damage was defined as either myocardial ischemia or infarction. No deaths, strokes, or symptomatic coronary events were observed during the early postoperative period. There were 112 low cardiac risk patients, 42 medium-risk patients, and 8 high-risk patients, according to stress echocardiography findings. Overall, there were 22 patients (14%) that increased their cTnI values postoperatively (12 of low cardiac risk and 10 of medium cardiac risk), and all of them were asymptomatic. None of the high-risk patients showed any troponin increase. Late cardiac events were associated with cTnI increase, although no high-risk patients showed any late event. Preoperative stress echocardiography does not seem to independently recognize patients in high risk for asymptomatic cardiac damage after CEA. Postoperative troponin elevation seems to be more predictive for late adverse cardiac events than preoperative stress echocardiography. © 2014, Wiley Periodicals, Inc.

  19. Stress echocardiography in valvular heart disease: a current appraisal.

    Science.gov (United States)

    Naji, Peyman; Patel, Krishna; Griffin, Brian P; Desai, Milind Y

    2015-03-01

    Stress echocardiography is increasingly used in the management of patients with valvular heart disease and can aid in evaluation, risk stratification and clinical decision making in these patients. Evaluation of symptoms, exercise capacity and changes in blood pressure can be done during the exercise portion of the test, whereas echocardiographic portion can reveal changes in severity of disease, pulmonary artery pressure and left ventricular function in response to exercise. These parameters, which are not available at rest, can have diagnostic and prognostic importance. In this article, we will review the indications and diagnostic implications, prognostic implications, and clinical impact of stress echocardiography in decision making and management of patients with valvular heart disease.

  20. Archeological Echocardiography: Digitization and Speckle Tracking Analysis of Archival Echocardiograms in the HyperGEN Study.

    Science.gov (United States)

    Aguilar, Frank G; Selvaraj, Senthil; Martinez, Eva E; Katz, Daniel H; Beussink, Lauren; Kim, Kwang-Youn A; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R; Arnett, Donna K; Shah, Sanjiv J

    2016-03-01

    Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. In the NHLBI HyperGEN study (N = 2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter-/intra-observer agreement was calculated. Accuracy was evaluated in: (1) a separate second study (N = 50) comparing prospective digital strain versus post hoc analog-to-digital strain, and (2) in a third study (N = 95) comparing prospectively obtained TDI e' velocities with post hoc STE e' velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intra-observer agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post hoc STE to prospective digital STE for strain analysis. STE-derived e' velocities correlated with, but systematically underestimated, TDI e' velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β = -2.4 [95% CI -3.6, -1.2]% per 1-SD increase in fasting glucose; P echocardiography, the digitization and speckle tracking analysis of archival echocardiograms, is feasible and generates indices of cardiac mechanics similar to contemporary studies. © 2015, Wiley Periodicals, Inc.

  1. Intraoperative transesophageal echocardiography in congenital heart diseases surgery

    International Nuclear Information System (INIS)

    Ozores Suarez, Francisco Javier; Perez de Ordaz, Luis Bravo

    2010-01-01

    The intraoperative transesophageal echocardiography is very used in pediatric cardiovascular surgery. The aim of present paper was to determine its impact on the surgery immediate results after a previous experience of authors with this type of procedure

  2. Transesophageal echocardiography. 3. rev. and enl. ed.; Transoesophageale Echokardiografie. Lehrbuch und Altlas zur Untersuchungstechnik und Befundinterpretation

    Energy Technology Data Exchange (ETDEWEB)

    Lambertz, Heinz [ECHOECUCT-Akademie, Wiesbaden (Germany); Lethen, Harald (eds.) [Internistische Intensivmedizin, Wiesbaden (Germany). Innere Medizin/Kardiologie

    2013-02-01

    The book on transesophageal echocardiography covers the following issues: Development of transesophageal echocardiography, technical advances; indications and contraindication for transesophageal echocardiography; systematic of the medical examination process; cardiac valves and valve prostheses; mitral and aortic valvuloplasty, TAVI and interventional treatment of mitral regurgitation; infectious endocarditis; one-way and effluence disturbances of the left and right ventricle; diseases of the thoracic aorta; undefined right ventricle enlargement; lung embolism, acute infarct complications; TEE during anesthesia and perioperative intensive medicine, cardiac sources of embolism; cardiac tumors, mediastinal lymph nodes; pericardiac diseases; congenital heart diseases in childhood and adulthood; catheter interventions and heart valve reconstruction; surgically corrected congenital cardiac defects; intracavitary versus transesophageal echocardiography; three-dimensional TEE; coronary diagnostics; ischemia and vitality diagnostics.

  3. Evaluation of regional wall motion abnormalities of the heart. Comparison with Doppler tissue echocardiography, MR-tagging and levocardiography

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Hamm, B.; Borges, A.C.; Walde, T.; Rutsch, W.; Baumann, G.

    2004-01-01

    Purpose: To compare the visual analysis of magnetic resonance imaging (MRI) with the tagging technique and Doppler tissue echocardiography with invasive ventriculography in detecting and quantifying regional left ventricular wall motion abnormalities. Materials and Methods: Sixteen patients with coronary artery disease and a history of prior myocardial infarction underwent invasive ventriculography. Doppler tissue echocardiography and MR-tagging within one week. Regional wall motion abnormalities (WMA) were detected in all patients. WMA were graded as normal=1; hypokinetic=2; akinetic=3; or dyskinetic=4. For agreement between MRI, echocardiography, and ventriculography the kappa coefficient (κ) according to Cohen was calculated. Results: The kappa coefficient (κ) was 0.962 for agreement between MRI and echocardiography and 0.602 for agreement between MRI and ventriculography as well as between echocardiography and ventriculography. Conclusion: Reliable analysis of regional left ventricular wall motion abnormalities is feasible using visual analysis of MR-tagging. MRI and Doppler tissue echocardiography detect more WMA than invasive ventriculography and grade them as more severe. (orig.)

  4. Outpatient echocardiography in the evaluation of innocent murmurs in children: utilisation benchmarking.

    Science.gov (United States)

    Frias, Patricio A; Oster, Matthew; Daley, Patricia A; Boris, Jeffrey R

    2016-03-01

    We sought to benchmark the utilisation of echocardiography in the outpatient evaluation of heart murmurs by evaluating two large paediatric cardiology centres. Although criteria exist for appropriate use of echocardiography, there are no benchmarking data demonstrating its utilisation. We performed a retrospective cohort study of outpatients aged between 0 and 18 years at the Sibley Heart Center Cardiology and the Children's Hospital of Philadelphia Division of Cardiology, given a sole diagnosis of "innocent murmur" from 1 July, 2007 to 31 October, 2010. Using internal claims data, we compared the utilisation of echocardiography according to centre, patient age, and physician years of service. Of 23,114 eligible patients (Sibley Heart Center Cardiology: 12,815, Children's Hospital of Philadelphia Division of Cardiology: 10,299), 43.1% (Sibley Heart Center Cardiology: 45.2%, Children's Hospital of Philadelphia Division of Cardiology: 40.4%; p1-5 years had the lowest utilisation (32.7%). In two large paediatric cardiology practices, the overall utilisation of echocardiography by physicians with a sole diagnosis of innocent murmur was similar. There was significant and similar variability in utilisation by provider at both centres. Although these data serve as initial benchmarking, the variability in utilisation highlights the importance of appropriate use criteria.

  5. The importance of echocardiography in diagnostics of idiopathic pulmonary arterial hypertension: A case report

    Directory of Open Access Journals (Sweden)

    Stojković Gabrijela

    2011-01-01

    Full Text Available Introduction. Idiopathic pulmonary arterial hypertension (IPAH is rare and difficult progressive disease with prevalence of approximately 15 cases per million residents, with predominant female cases. Case Outline. A 47-year-old female presented with symptoms and signs of the right heart chambers failure. Over prior seven years the patient had the feeling of suffocation and fatigue when walking, and received treatment for bronchial asthma. Physical examination revealed a marked loud second heart sound over the pulmonary artery. Electrocardiogram: right ventricular hypertrophy. Spirometric (pulmonary capacity test, cardiac perfusion scan and spiral CT scanning excluded secondary pulmonary arterial hypertension. Blood testing for connective tissue diseases and HIV were within normal reference limits. Transthoracic colour Doppler echocardiography demonstrated a mild tricuspid regurgitation with high values of estimated maximal and middle systolic pressure of the right ventricle (135/110 mm Hg, and excluded previous heart disease. Cardiac catheterization confirmed IPAH diagnosis, with systolic right ventricular pressure of 101/47/66 mm Hg and pulmonary capillary pressure of 30/13/10 mm Hg. Basic therapy with sildenafil, nevertheless, considerable limitations of strain tolerance was still present. Conclusion. IPAH is a severe heart disease with non-specific signs and symptoms. Screening for IPAH is transthoracic colour Doppler echocardiography shows high correlation with cardiac catheterization.

  6. Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment

    Directory of Open Access Journals (Sweden)

    Dimitrow Paweł

    2003-04-01

    Full Text Available Abstract This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery. Post-stenotic CFR measurement is helpful in: functional assessment of moderate stenosis, detection of significant or critical stenosis, monitoring of restenosis after revascularization. In the absence of stenosis in the epicardial coronary artery, decreased CFR enable to detect impaired microvascular vasodilatation in: reperfused myocardial infarct, arterial hypertension with or without left ventricular hypertrophy, diabetes mellitus, hypercholesterolemia, syndrome X, hypertrophic cardiomyopathy. In these diseases, noninvasive transthoracic Doppler echocardiography allows for serial CFR evaluations to explore the effect of various pharmacological therapies.

  7. Pulmonary artery occlusion pressure estimation by transesophageal echocardiography: is simpler better?

    Science.gov (United States)

    Voga, Gorazd

    2008-01-01

    The measurement of pulmonary artery occlusion pressure (PAOP) is important for estimation of left ventricular filling pressure and for distinction between cardiac and non-cardiac etiology of pulmonary edema. Clinical assessment of PAOP, which relies on physical signs of pulmonary congestion, is uncertain. Reliable PAOP measurement can be performed by pulmonary artery catheter, but it is possible also by the use of echocardiography. Several Doppler variables show acceptable correlation with PAOP and can be used for its estimation in cardiac and critically ill patients. Noninvasive PAOP estimation should probably become an integral part of transthoracic and transesophageal echocardiographic evaluation in critically ill patients. However, the limitations of both methods should be taken into consideration, and in specific patients invasive PAOP measurement is still unavoidable, if the exact value of PAOP is needed.

  8. Correlation of double-contrast high-density barium enema, colonoscopy, and histology in children with special attention to disparities

    International Nuclear Information System (INIS)

    Stringer, D.A.; Sherman, P.M.; Jakowenko, N.

    1986-01-01

    Colonscopic and double-contrast high-density barium enema (DCBE) findings were correlated in 68 patients (39 boys and 29 girls) aged 6 months to 18 years (mean 11.6 years) evaluated over a 24-month period. There was excellent correlation in 53 patients (78.0%) and good correlation in another 3 (4.4%) who had identical diagnoses and only slightly differing extent of disease reported. In 2 of these, DCBE showed more extensive disease, confirmed histologically in 1. Distal colitis seen on colonoscopy as reddening and neovascularity was missed on DCBE in 6 patients. Colonoscopy and DEBE failed to show a polyp in 1 patient each. One patient who had a normal DCBE and colonoscopy demonstrated a histological abnormality, and 1 patient with an abnormality on histology and DCBE was normal on colonscopy. A disparity resulted from the time between procedures in 1 patient and observer error in another. This high correlation is far better than any previously reported in children, supporting the use of high-density barium sulfate and double-contrast barium enemas in pediatric patients. (orig.)

  9. Speckle-tracking echocardiography for predicting outcome in chronic aortic regurgitation during conservative management and after surgery

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; Søgaard, Peter; Larsson, Henrik B W

    2011-01-01

    Objectives The aim of this study was to test myocardial deformation imaging using speckle-tracking echocardiography for predicting outcomes in chronic aortic regurgitation. Background In chronic aortic regurgitation, left ventricular (LV) dysfunction must be detected early to allow timely surgery....... Speckle-tracking echocardiography has been proposed for this purpose, but the clinical value of this method in aortic regurgitation has not been established. Methods A longitudinal study was performed in 64 patients with moderate to severe aortic regurgitation. Thirty-five patients were managed...... conservatively with frequent clinical visits and sequential echocardiography and followed for an average of 19 ± 8 months, while 29 patients underwent surgery for the valve lesion and were followed for 6 months post-operatively. Baseline LV function by speckle-tracking and conventional echocardiography...

  10. Prognostic Value of Exercise-Stress Echocardiography in Asymptomatic Patients With Aortic Valve Stenosis.

    Science.gov (United States)

    Goublaire, Coppelia; Melissopoulou, Maria; Lobo, David; Kubota, Naozumi; Verdonk, Constance; Cimadevilla, Claire; Codogno, Isabelle; Brochet, Eric; Vahanian, Alec; Messika-Zeitoun, David

    2017-07-19

    This study sought to evaluate the prognostic value of mean pressure gradient (MPG) increase and peak systolic pulmonary artery pressure (SPAP) measured during exercise stress echocardiography in asymptomatic patients with aortic stenosis (AS). Exercise testing is recommended in asymptomatic AS patients, but the additional value of exercise-stress echocardiography, especially the prognostic value of MPG increase and peak SPAP, is still debated. We enrolled all consecutive patients with pure, isolated, asymptomatic AS and preserved ejection fraction ≥50% and normal SPAP (20 mm Hg and/or SPAP at peak exercise >60 mm Hg). These 112 patients were managed conservatively. During a mean follow-up of 14 ± 8 months, an AS-related event occurred in 30 patients, and 25 patients underwent surgery. Neither MPG increase >20 mm Hg nor peak SPAP >60 mm Hg was predictive of occurrence of AS-related events or aortic valve replacement (all p > 0.20). In contrast, baseline AS severity was an important prognostic factor (all p < 0.01). In this observational study including 148 patients with asymptomatic AS, we confirmed and extended the importance of exercise testing for unveiling functional limitation. More importantly, neither the increase in MPG nor in SPAP at peak exercise was predictive of outcome. Our results do not support the use of these parameters in risk-stratification and clinical management of asymptomatic AS patients. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Left atrial volume assessment in atrial fibrillation using multimodality imaging: a comparison of echocardiography, invasive three-dimensional CARTO and cardiac magnetic resonance imaging.

    Science.gov (United States)

    Rabbat, Mark G; Wilber, David; Thomas, Kevin; Malick, Owais; Bashir, Atif; Agrawal, Anoop; Biswas, Santanu; Sanagala, Thriveni; Syed, Mushabbar A

    2015-06-01

    Left atrial size in atrial fibrillation is a strong predictor of successful ablation and cardiovascular events. Cardiac magnetic resonance multislice method (CMR-MSM) is the current gold standard for left atrial volume (LAV) assessment but is time consuming. We investigated whether LAV with more rapid area-length method by echocardiography (Echo-AL) or cardiac magnetic resonance (CMR-AL) and invasive measurement by 3D-CARTO mapping during ablation correlate with the CMR-MSM. We studied 250 consecutive patients prior to atrial fibrillation ablation. CMR images were acquired on 3T scanner to measure LAV by MSM and biplane area-length method. Standard echocardiography views were used to calculate LAV by biplane area-length method. LAV during ablation was measured by 3D-CARTO mapping. LAV was compared using intra-class correlation (ICC), Pearson's correlation and Bland-Altman plots. CMR-MSM was used as the reference standard. Mean LAV using CMR-MSM was 112.7 ± 36.7 ml. CMR-AL method overestimated LAV by 13.3 ± 21.8 ml (11.2%, p atrial fibrillation. CMR-AL and 3D-CARTO correlated and agreed well with CMR-MSM (r = 0.87 and 0.74, ICC = 0.80 and 0.77 respectively). However, Echo-AL had poor correlation and agreement with CMR-MSM (r = 0.66 and ICC = 0.48). Bland-Altman plots confirmed these findings. CMR-AL method may be used as an alternative to CMR-MSM, as it is non-invasive, rapid, and correlates well with CMR-MSM. LAV by different modalities should not be used interchangeably.

  12. Real-time three-dimensional speckle tracking echocardiography: technical aspects and clinical applications

    Directory of Open Access Journals (Sweden)

    Sorrentino R

    2016-11-01

    Full Text Available Regina Sorrentino, Roberta Esposito, Enrica Pezzullo, Maurizio Galderisi Department of Advanced Biomedical Sciences, Interdepartmental Laboratory of Cardiac Imaging, Federico II University Hospital, Naples, Italy Abstract: Three-dimensional speckle tracking echocardiography (3D STE is a novel technique for the quantification of cardiac deformation based on tracking of ultrasonic speckles in gray scale full-volume 3D images. Developments in ultrasound technologies have made 3D speckle tracking widely available. Two-dimensional echocardiography has intrinsic limitations regarding estimation of left ventricular (LV volumes, ejection fraction, and LV mechanics, due to its inherent foreshortening errors and dependency on geometric models. The development of 3D echocardiography has improved reproducibility and accuracy. Data regarding the feasibility, accuracy, and clinical applications of 3D STE are rapidly assembling. From the tracking results, 3D STE derives several parameters, including longitudinal, circumferential and radial strain, as well as a combined assessment of longitudinal and circumferential strain, termed area strain. 3D STE can also quantify LV rotational movements such as rotation, twist, and torsion. 3D STE provides a better insight on global and regional myocardial deformation. Main applications include detection of subclinical myocardial involvement in heart failure, arterial hypertension, dyssynchrony, and ischemic heart disease. Emerging areas of application include a large spectrum of heart-involving systemic conditions, such as prediction of rejection in heart transplant patients, early detection of cardiotoxicity in patients receiving chemotherapy for cancer, and deeper physiological understanding of LV contraction mechanics in different types of athletes. Aim of this review is to discuss background, technical acquisition and processing aspects as well as recognized and developing clinical applications of this emerging

  13. Left ventricular thrombi: in vivo detection by indium-111 platelet imaging and two dimensional echocardiography

    International Nuclear Information System (INIS)

    Stratton, J.R.; Ritchie, J.L.; Hamilton, G.W.; Hammermeister, K.E.; Harker, L.A.

    1981-01-01

    Indium-111 platelet imaging, which can identify sites of active intravascular platelet deposition, and two dimensional echocardiography, which can identify intracardiac masses, can both be used to detect left ventricular thrombi noninvasively. We compared these techniques in 44 men at risk for thrombi from remote transmural myocardial infarction (31 patients) or cardiomyopathy (13 patients). All 44 patients underwent platelet imaging; 35 underwent echocardiography. On platelet imaging nine patients had thrombi and onehad a possible thrombus. Of these 10 studies, none were positive at 2 hours, 5 were positive at 24 hours and all were positive 48 or 72 hours after platelet labeling. Nine of these patients underwent echocardiography, and all had an intraventricular mass. The findings on platelet scanning were negative in six patients who had positive (four patients) or equivocally positive (two patients) findings on echocardiography. All patients with thrombi detected by either noninvasive method had transmural anterior myocardial infarction with ventricular aneurysm. Of the seven patients who underwent cardiac surgery or autopsy, three had thrombi. Platelet imaging failed to identify one thrombus in a patient in whom imaging was performed only at 24 hours after labeling. There were no false positive platelet images in this group. Five of these seven patients (two with throbi, three without) underwent echocardiography; in all cases the echocardiographic findings agreed with the pathologic findings. Both platelet imaging and echocardiography detect ventricular thrombi. Platelet imaging may detect only the most hematologically active thrombi. Both techniques may help define patients at risk of embolization and may be useful for in vivo assessment of antithrombotic drugs

  14. Contrast-enhanced ultrasonography of hepatocellular carcinoma: Correlation between quantitative parameters and arteries in neoangiogenesis or sinusoidal capillarization

    International Nuclear Information System (INIS)

    Pei Xiaoqing; Liu Longzhong; Zheng Wei; Cai Muyan; Han Feng; He Jiehua; Li Anhua; Chen Minshan

    2012-01-01

    Objective: The quantitative parameters in contrast-enhanced ultrasonography-time–intensity curve of hepatocellular carcinoma (HCC) were studied to explore their potential importance in monitoring the effects of anti-angiogenic therapy for HCC. Methods: 115 HCC patients were studied with contrast-enhanced ultrasonography-time–intensity curve (CEUS-TIC) and with immunohistochemical analysis of tissue sections. The CEUS images were analyzed off-line to obtained quantitative parameters including maximum of intensity (IMAX), rise time (RT), time to peak (TTP), mean transit time (mTT), rise slope (RS), and washout time (WT). Monoclonal antibodies specific for smooth muscle actin and anti-CD34 were used to observe unpaired arteries (UAs) and microvessel area (MVA) of sinusoidal capillarization, respectively. The UAs and MVA of 82 HCC cases were successfully stained. Results: The number of UAs had moderate correlation with RT (r = −0.446), TTP (r = −0.432), and RS (r = 0.431) (P < 0.05), and it had mild correlation with IMAX (r = 0.303) and WT (r = 0.285) (P < 0.05). MVA of sinusoidal capillarization had no correlation with perfusion parameters. Conclusion: Quantitative CEUS-TIC parameters reflecting hemodynamics of tumors are correlated with UAs, but not with MVA, and they might be used to monitor the effects of anti-angiogenic therapy on HCC.

  15. The current status of fluoroscopy and echocardiography in the diagnosis of prosthetic valve thrombosis-a review article.

    Science.gov (United States)

    Gürsoy, Mustafa Ozan; Kalçik, Macit; Karakoyun, Süleyman; Özkan, Mehmet

    2015-01-01

    Prosthetic valve thrombosis (PVT) is a potentially life-threatening complication of heart valve replacement. Early diagnosis is crucial for the prevention of significantly morbid and lethal complications. Cinefluoroscopy (CF) and echocardiography have been widely used for diagnosing PVT. In recent years, the role of CF has declined since the introduction of transesophageal echocardiography and the great improvements in ultrasound technology including real time three-dimensional imaging. Nevertheless, both echocardiography and CF provide different kinds of information on prosthesis function, and therefore they are considered as complementary and not alternative. In this review, we aimed to summarize the current status of CF and echocardiography in the diagnosis of PVT. © 2014, Wiley Periodicals, Inc.

  16. Quantitative assessment of left ventricular systolic function using 3-dimensional echocardiography

    Directory of Open Access Journals (Sweden)

    Rahul Mehrotra

    2013-09-01

    Full Text Available Assessment of left ventricular systolic function is the commonest and one of the most important indications for performance of echocardiography. It is important for prognostication, determination of treatment plan, for decisions related to expensive device therapies and for assessing response to treatment. The current methods based on two-dimensional echocardiography are not reliable, have high degree of inter-observer and intra-observer variability and are based on presumptions about the geometry of left ventricle (LV. Real-time three-dimensional echocardiography (RT3DE on the other hand is fast, easy, accurate, relatively operator independent and is not based on any assumptions related to the shape of LV. Owing to these advantages, it is the Echocardiographic modality of choice for assessment of systolic function of the LV. We describe here a step by step approach to evaluation of LV volumes, ejection fraction, regional systolic function and Dyssynchrony analysis based on RT3DE. It has been well validated in clinical studies and is rapidly being incorporated in routine clinical practice.

  17. Correlation between observation task performance and visual acuity, contrast sensitivity and environmental light in a simulated maritime study.

    Science.gov (United States)

    Koefoed, Vilhelm F; Assmuss, Jörg; Høvding, Gunnar

    2018-03-25

    To examine the relevance of visual acuity (VA) and index of contrast sensitivity (ICS) as predictors for visual observation task performance in a maritime environment. Sixty naval cadets were recruited to a study on observation tasks in a simulated maritime environment under three different light settings. Their ICS were computed based on contrast sensitivity (CS) data recorded by Optec 6500 and CSV-1000E CS tests. The correlation between object identification distance and VA/ICS was examined by stepwise linear regression. The object detection distance was significantly correlated to the level of environmental light (p maritime environment may presumably be ascribed to the normal and uniform visual capacity in all our study subjects. © 2018 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  18. Relationship between myocardial extracellular space expansion estimated with post-contrast T1 mapping MRI and left ventricular remodeling and neurohormonal activation in patients with dilated cardiomyopathy

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Ji Hyun; Son, Jung Woo; Chung, Hye Moon [Cardiology Division, Dept. of Internal Medicine, Yonsei University College of Medicine, Seoul (Korea, Republic of); and others

    2015-10-15

    Post-contrast T1 values are closely related to the degree of myocardial extracellular space expansion. We determined the relationship between post-contrast T1 values and left ventricular (LV) diastolic function, LV remodeling, and neurohormonal activation in patients with dilated cardiomyopathy (DCM). Fifty-nine patients with DCM (mean age, 55 ± 15 years; 41 males and 18 females) who underwent both 1.5T magnetic resonance imaging and echocardiography were enrolled. The post-contrast 10-minute T1 value was generated from inversion time scout images obtained using the Look-Locker inversion recovery sequence and a curve-fitting algorithm. The T1 sample volume was obtained from three interventricular septal points, and the mean T1 value was used for analysis. The N-Terminal pro-B-type natriuretic peptide (NT-proBNP) level was measured in 40 patients. The mean LV ejection fraction was 24 ± 9% and the post-T1 value was 254.5 ± 46.4 ms. The post-contrast T1 value was significantly correlated with systolic longitudinal septal velocity (s'), peak late diastolic velocity of the mitral annulus (a'), the diastolic elastance index (Ed, [E/e']/stroke volume), LV mass/volume ratio, LV end-diastolic wall stress, and LV end-systolic wall stress. In a multivariate analysis without NT-proBNP, T1 values were independently correlated with Ed (β = -0.351, p = 0.016) and the LV mass/volume ratio (β = 0.495, p = 0.001). When NT-proBNP was used in the analysis, NT-proBNP was independently correlated with the T1 values (β = -0.339, p = 0.017). Post-contrast T1 is closely related to LV remodeling, diastolic function, and neurohormonal activation in patients with DCM.

  19. Physical Stress Echocardiography: Prediction of Mortality and Cardiac Events in Patients with Exercise Test showing Ischemia

    Directory of Open Access Journals (Sweden)

    Ana Carla Pereira de Araujo

    2014-11-01

    Full Text Available Background: Studies have demonstrated the diagnostic accuracy and prognostic value of physical stress echocardiography in coronary artery disease. However, the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia is limited. Objective: To evaluate the effectiveness of physical stress echocardiography in the prediction of mortality and major cardiac events in patients with exercise test positive for myocardial ischemia. Methods: This is a retrospective cohort in which 866 consecutive patients with exercise test positive for myocardial ischemia, and who underwent physical stress echocardiography were studied. Patients were divided into two groups: with physical stress echocardiography negative (G1 or positive (G2 for myocardial ischemia. The endpoints analyzed were all-cause mortality and major cardiac events, defined as cardiac death and non-fatal acute myocardial infarction. Results: G2 comprised 205 patients (23.7%. During the mean 85.6 ± 15.0-month follow-up, there were 26 deaths, of which six were cardiac deaths, and 25 non-fatal myocardial infarction cases. The independent predictors of mortality were: age, diabetes mellitus, and positive physical stress echocardiography (hazard ratio: 2.69; 95% confidence interval: 1.20 - 6.01; p = 0.016. The independent predictors of major cardiac events were: age, previous coronary artery disease, positive physical stress echocardiography (hazard ratio: 2.75; 95% confidence interval: 1.15 - 6.53; p = 0.022 and absence of a 10% increase in ejection fraction. All-cause mortality and the incidence of major cardiac events were significantly higher in G2 (p < 0. 001 and p = 0.001, respectively. Conclusion: Physical stress echocardiography provides additional prognostic information in patients with exercise test positive for myocardial ischemia.

  20. Echocardiography diagnosis of myocardial infarction complications

    Directory of Open Access Journals (Sweden)

    N.D. Oryshchyn

    2016-03-01

    Full Text Available Diagnosis and management of myocardial infarction complications are discussed in this article. These complications are associated with high level of mortality and surgery is a main treatment method. High level of suspicion and early diagnosis are essential for appropriate treatment and improvement of prognosis. Echocardiography is a main diagnostic method. Analysis of literature about contemporary management of mechanical complications of myocardial infarction has been performed, case reports are presented.

  1. Advanced echocardiography and clinical surrogates to risk stratify and manage patients with structural heart disease

    NARCIS (Netherlands)

    Debonnaire, Philippe Jean Marc Rita

    2016-01-01

    Part I focuses on the potential role of 3-dimensional echocardiography. At first a clinical risk score model for prediction of outcome in patients undergoing TAVI is presented (Chapter 2). Second the role of 3D-echocardiography is explored in depth in patients with mitral valve disease. Different

  2. Healed perivalvular abscess: Incidental finding on transthoracic echocardiography

    Directory of Open Access Journals (Sweden)

    Vishnu Datt

    2014-01-01

    Full Text Available A 36-year-old male patient presented with the complaints of palpitations and breathlessness. Preoperative transthoracic echocardiography (TTE revealed a bicuspid aortic valve; severe aortic regurgitation with dilated left ventricle (LV and mild LV systolic dysfunction (ejection fraction 50%. He was scheduled to undergo aortic valve replacement. History was not suggestive of infective endocarditis (IE. Preoperative TTE did not demonstrate any aortic perivalvular abscess. Intraoperative transesophageal echocardiography (TEE examination using the mid-esophageal (ME long-axis view, showed an abscess cavity affecting the aortic valve, which initially was assumed to be a dissection flap, but later confirmed to be an abscess cavity by color Doppler examination. The ME aortic valve short-axis view showed two abscesses; one was at the junction of the non-coronary and left coronary commissure and the other one above the right coronary cusp. Intraoperatively, these findings were confirmed by the surgeons. The case report demonstrates the superiority of TEE over TTE in diagnosing perivalvular abscesses.

  3. On-Orbit Prospective Echocardiography on International Space Station

    Science.gov (United States)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Martin, David; Garcia, Kathleen M.; Melton, Shannon; Feiverson, Alan; Dulchavsky, Scott A.

    2010-01-01

    A number of echocardiographic research projects and experiments have been flown on almost every space vehicle since 1970, but validation of standard methods and the determination of Space Normal cardiac function has not been reported to date. Advanced Diagnostics in Microgravity (ADUM) -remote guided echocardiographic technique provides a novel and effective approach to on-board assessment of cardiac physiology and structure using a just-in-time training algorithm and real-time remote guidance aboard the International Space Station (ISS). The validation of remotely guided echocardiographic techniques provides the procedures and protocols to perform scientific and clinical echocardiography on the ISS and the Moon. The objectives of this study were: 1.To confirm the ability of non-physician astronaut/cosmonaut crewmembers to perform clinically relevant remotely guided echocardiography using the Human Research Facility on board the ISS. 2.To compare the preflight, postflight and in-flight echocardiographic parameters commonly used in clinical medicine.

  4. Temporal enhancement of two-dimensional color doppler echocardiography

    Science.gov (United States)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  5. Echocardiography as a Screening Test for Myocardial Scarring in Children with Hypertrophic Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Gregory Compton

    2016-01-01

    Full Text Available Introduction. Hypertrophic cardiomyopathy (HCM is burdened with morbidity and mortality including tachyarrhythmias and sudden cardiac death. These complications are attributed in part to the formation of proarrhythmic scars in the myocardium. The presence of extensive LGE is a risk factor for adverse outcomes in HCM. Late gadolinium enhancement (LGE cardiac magnetic resonance imaging (cMRI is the standard for the noninvasive evaluation of myocardial scars. However, echocardiography represents an attractive screening tool for myocardial scarring. The aim of this study was to compare the suitability of echocardiography to detect myocardial scars to the standard of cMRI-LGE. Methods. The cMRI studies and echocardiograms from 56 consecutive children with HCM were independently evaluated for the presence of cMRI-LGE and echocardiographic evidence of scarring by expert readers. Results. Echocardiography had a high sensitivity (93% and negative predictive value (94% in comparison to LGE. The false positive rate was high, leading to a low specificity (37% and a low positive predictive value (35%. Conclusions. Given the poor specificity and positive predictive value, echocardiography is not a suitable screening test for the presence of myocardial scarring in children with HCM. However, children without echocardiographic evidence of myocardial scarring may not need to undergo cardiac magnetic resonance imaging to “rule in” LGE.

  6. Prosthetic tricuspid valve dysfunction assessed by three-dimensional transthoracic and transesophageal echocardiography.

    Science.gov (United States)

    Yuasa, Toshinori; Takasaki, Kunitsugu; Mizukami, Naoko; Ueya, Nami; Kubota, Kayoko; Horizoe, Yoshihisa; Chaen, Hideto; Kuwahara, Eiji; Kisanuki, Akira; Hamasaki, Shuichi

    2013-09-01

    A 39-year-old male who had undergone tricuspid valve replacement for severe tricuspid regurgitation was admitted with palpitation and general edema. Two-dimensional (2D) echocardiography showed tricuspid prosthetic valve dysfunction. Additional three-dimensional (3D) transthoracic and transesophageal echocardiography (TEE) could clearly demonstrate the disabilities of the mechanical tricuspid valve. Particularly, 3D TEE demonstrated a mass located on the right ventricular side of the tricuspid prosthesis, which may have caused the stuck disk. This observation was confirmed by intra-operative findings.

  7. Tissue doppler echocardiography for evaluating left ventricular functions in obese

    Directory of Open Access Journals (Sweden)

    Mecnun Çetin

    2013-03-01

    Full Text Available Objective: The aim of this study was to investigate theimpact of childhood obesity on ventricular functions usingtissue Doppler echocardiography.Materials and methods: The mitral tissue Doppler signalswere recorded in the apical four-chamber view, with thesample volume placed at the lateral walls of mitral annulus.The mitral flow was examined with the sample Pulse Dopplerpositioned parallely to flow just at the orifice of the mitralleaflets. Twenty obese (mean age, 161.5±25.8 monthsand 20 healthy children (mean age, 151.2±33.5 monthswere included to this study.Results: Body mass index (BMI was significantly higherin obese group (30.92±6.87. Isovolumic relaxation time(IVRT which is one of the left ventricular (LV diastolicfunction parameters was 66.10±7.30 ms in obese group,and 58.70±9.06 ms in the control group. IVRT was significantlyhigher in the obese group (p=0.007. In obesegroup, the mitral annulus tissue Doppler E velocity wasdecreased, flow velocity was increased and decrement inEm/Am ratio was significant. We found significant negativecorrelation between BMI and LV Em/Am ratio. Myocardialperformance index (MPI in obese group and control groupwas 0.50±0.07 and 0.41±0.04, respectively (p<0.001.Between MPI and LV Em/Am ratio there was a significantnegative correlation while MPI showed positive correlationwith BMI. In obese group septal and LV posterior wall thicknesswas shown to be significantly increased compared tothe control group (p<0.001.Conclusion: Our findings, may be important for determinationof the relationship between obesity and cardiovascularrisk factors in children. Tissue Doppler echocardiographicimaging may be useful in revealing this relationship.Key words: obesity, doppler echocardiography, ventricular dysfunction

  8. Automatic detection of end-diastole and end-systole from echocardiography images using manifold learning

    International Nuclear Information System (INIS)

    Gifani, Parisa; Behnam, Hamid; Shalbaf, Ahmad; Sani, Zahra Alizadeh

    2010-01-01

    The automatic detection of end-diastole and end-systole frames of echocardiography images is the first step for calculation of the ejection fraction, stroke volume and some other features related to heart motion abnormalities. In this paper, the manifold learning algorithm is applied on 2D echocardiography images to find out the relationship between the frames of one cycle of heart motion. By this approach the nonlinear embedded information in sequential images is represented in a two-dimensional manifold by the LLE algorithm and each image is depicted by a point on reconstructed manifold. There are three dense regions on the manifold which correspond to the three phases of cardiac cycle ('isovolumetric contraction', 'isovolumetric relaxation', 'reduced filling'), wherein there is no prominent change in ventricular volume. By the fact that the end-systolic and end-diastolic frames are in isovolumic phases of the cardiac cycle, the dense regions can be used to find these frames. By calculating the distance between consecutive points in the manifold, the isovolumic frames are mapped on the three minimums of the distance diagrams which were used to select the corresponding images. The minimum correlation between these images leads to detection of end-systole and end-diastole frames. The results on six healthy volunteers have been validated by an experienced echo cardiologist and depict the usefulness of the presented method

  9. Dynamic contrast-enhanced MRI of benign prostatic hyperplasia and prostatic carcinoma: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ren, J.; Huan, Y.; Wang, H.; Chang, Y.-J.; Zhao, H.-T.; Ge, Y.-L.; Liu, Y.; Yang, Y.

    2008-01-01

    Aim: To investigate the diagnostic and differential diagnostic values of dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) in prostatic diseases, and to investigate the correlation between the parameters of SI-T curves and angiogenesis. Materials and methods: Twenty-one patients with proven prostatic carcinoma (Pca) and 29 patients with proven benign prostatic hyperplasia (BPH) were examined using DCE MRI. Diagnostic characteristics for differentiation were examined using threshold values for maximum peak time, enhancement degree, and enhancement rate. Then, the signal intensity-time curves (SI-T curves) were analysed, and the correlations between the parameters of SI-T curves and the expression levels of vascular endothelial growth factor (VEGF) and microvascular density (MVD) were investigated. All patients underwent prostatectomy. DCE MRI and histological findings were correlated. Results: Pca showed stronger enhancement with an earlier peak time, higher enhancement, and enhancement rate (p 2 = 13.57, P < 0.005). The VEGF and MVD expression levels of Pca were higher than those of BPH. Peak time was negatively correlated with the expression levels of VEGF and MVD, whereas the enhancement degree and enhancement rate showed positive correlations (Pearson correlation, p < 0.05). Conclusion: Based on T2-weighted imaging, DCE MRI curves can help to differentiate benign from malignant prostate tissue. In the present study the type C curve was rarely seen with malignant disease, but these results need confirmation

  10. Feasibility of transesophageal echocardiography in birds without cardiac disease.

    Science.gov (United States)

    Beaufrère, Hugues; Pariaut, Romain; Nevarez, Javier G; Tully, Thomas N

    2010-03-01

    To establish a technique of transesophageal echocardiography (TEE) in birds without cardiac disease and describe the imaging planes obtained. Validation study. 18 birds including 3 pigeons (Columbia livia), 3 barred owls (Strix varia), 2 red-tailed hawks (Buteo jamaicensis), 1 goose (Anser anser), 1 mallard duck (Anas platyrhynchos), 1 Muscovy duck (Cairina moschata), 2 brown pelicans (Pelecanus occidentalis), 2 Hispaniolan Amazon parrots (Amazona ventralis), 2 red-fronted macaws (Ara rubrogenys), and 1 military macaw (Ara militaris). For each bird, anesthesia was induced and maintained by use of isoflurane. A pediatric, multiplane transesophageal ultrasound probe was passed into the esophagus and adjusted to the level of the heart for echocardiography. Probe positions were recorded via fluoroscopy, and associated imaging planes were described. TEE was performed successfully in all birds except the pelicans, 1 Hispaniolan Amazon parrot, and the red-fronted macaws. Five imaging planes of the heart were consistently viewed from 3 positions of the probe (identified as caudal, middle, and cranial positions relative to the cardiac silhouette). M-mode echocardiography of the left ventricle and the aortic root was performed. Color flow and spectral Doppler ultrasonographic images of in- and outflow regions were obtained. One Hispaniolan Amazon parrot died as a result of esophageal perforation. TEE examination of birds was feasible and provided a larger number of imaging planes with better resolution and details than those typically achieved via a transcoelomic approach. However, TEE should be performed with caution in psittacines.

  11. Detection of heart disease by open access echocardiography: a retrospective analysis of general practice referrals.

    Science.gov (United States)

    Chambers, John; Kabir, Saleha; Cajeat, Eric

    2014-02-01

    Heart disease is difficult to detect clinically and it has been suggested that echocardiography should be available to all patients with possible cardiac symptoms or signs. To analyse the results of 2 years of open access echocardiography for the frequency of structural heart disease according to request. Retrospective database analysis in a teaching hospital open access echocardiography service. Reports of all open access transthoracic echocardiograms between January 2011 and December 2012 were categorised as normal, having minor abnormalities, or significant abnormalities according to the indication. There were 2343 open access echocardiograms performed and there were significant abnormalities in 29%, predominantly valve disease (n = 304, 13%), LV systolic dysfunction (n = 179, 8%), aortic dilatation (n = 80, 3%), or pulmonary hypertension (n = 91, 4%). If echocardiography had been targeted at a high-risk group, 267 with valve disease would have been detected (compared to 127 with murmur alone) and 139 with LV systolic dysfunction (compared to 91 with suspected heart failure alone). Most GP practices requested fewer than 10 studies, but 6 practices requested over 70 studies. Open access echocardiograms are often abnormal but structural disease may not be suspected from the clinical request. Uptake by individual practices is patchy. A targeted expansion of echocardiography in patients with a high likelihood of disease is therefore likely to increase the detection of clinically important pathology.

  12. Angio- and echocardiography: viewing heart defects in more detail

    International Nuclear Information System (INIS)

    Goodwin, J.K.; Lombard, C.W.

    1990-01-01

    Angio- and echocardiography can help to confirm the diagnosis or evaluate the severity of a heart defect. Angiograms of dogs with pulmonic stenosis and tetralogy of Fallot are shown. Echocardiographic features of common congenital heart defects are summarized

  13. Three-dimensional adult echocardiography: where the hidden dimension helps.

    Science.gov (United States)

    Mor-Avi, Victor; Sugeng, Lissa; Lang, Roberto M

    2008-05-01

    The introduction of three-dimensional (3D) imaging and its evolution from slow and labor-intense off-line reconstruction to real-time volumetric imaging is one of the most significant developments in ultrasound imaging of the heart of the past decade. This imaging modality currently provides valuable clinical information that empowers echocardiography with new levels of confidence in diagnosing heart disease. One major advantage of seeing the additional dimension is the improvement in the accuracy of the evaluation of cardiac chamber volumes by eliminating geometric modeling and the errors caused by foreshortened views. Another benefit of 3D imaging is the realistic views of cardiac valves capable of demonstrating numerous pathologies in a unique, noninvasive manner. This article reviews the major technological developments in 3D echocardiography and some of the recent literature that has provided the scientific basis for its clinical use.

  14. Quantification of global myocardial function by cine MRI deformable registration-based analysis: Comparison with MR feature tracking and speckle-tracking echocardiography

    International Nuclear Information System (INIS)

    Lamacie, Mariana M.; Thavendiranathan, Paaladinesh; Hanneman, Kate; Greiser, Andreas; Jolly, Marie-Pierre; Ward, Richard; Wintersperger, Bernd J.

    2017-01-01

    To evaluate deformable registration algorithms (DRA)-based quantification of cine steady-state free-precession (SSFP) for myocardial strain assessment in comparison with feature-tracking (FT) and speckle-tracking echocardiography (STE). Data sets of 28 patients/10 volunteers, undergoing same-day 1.5T cardiac MRI and echocardiography were included. LV global longitudinal (GLS), circumferential (GCS) and radial (GRS) peak systolic strain were assessed on cine SSFP data using commercially available FT algorithms and prototype DRA-based algorithms. STE was applied as standard of reference for accuracy, precision and intra-/interobserver reproducibility testing. DRA showed narrower limits of agreement compared to STE for GLS (-4.0 [-0.9,-7.9]) and GCS (-5.1 [1.1,-11.2]) than FT (3.2 [11.2,-4.9]; 3.8 [13.9,-6.3], respectively). While both DRA and FT demonstrated significant differences to STE for GLS and GCS (all p<0.001), only DRA correlated significantly to STE for GLS (r=0.47; p=0.006). However, good correlation was demonstrated between MR techniques (GLS:r=0.74; GCS:r=0.80; GRS:r=0.45, all p<0.05). Comparing DRA with FT, intra-/interobserver coefficient of variance was lower (1.6 %/3.2 % vs. 6.4 %/5.7 %) and intraclass-correlation coefficient was higher. DRA GCS and GRS data presented zero variability for repeated observations. DRA is an automated method that allows myocardial deformation assessment with superior reproducibility compared to FT. (orig.)

  15. Quantification of global myocardial function by cine MRI deformable registration-based analysis: Comparison with MR feature tracking and speckle-tracking echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Lamacie, Mariana M. [University Health Network, Department of Medical Imaging, Toronto, Ontario (Canada); Thavendiranathan, Paaladinesh [University Health Network, Department of Medical Imaging, Toronto, Ontario (Canada); University of Toronto, Department of Medicine, Division of Cardiology, Toronto, Ontario (Canada); Hanneman, Kate [University Health Network, Department of Medical Imaging, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Greiser, Andreas [Siemens Healthcare, Erlangen (Germany); Jolly, Marie-Pierre [Medical Imaging Technologies, Siemens Healthcare, Princeton, NJ (United States); Ward, Richard [University of Toronto, Department of Medicine, Division of Cardiology, Toronto, Ontario (Canada); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-04-15

    To evaluate deformable registration algorithms (DRA)-based quantification of cine steady-state free-precession (SSFP) for myocardial strain assessment in comparison with feature-tracking (FT) and speckle-tracking echocardiography (STE). Data sets of 28 patients/10 volunteers, undergoing same-day 1.5T cardiac MRI and echocardiography were included. LV global longitudinal (GLS), circumferential (GCS) and radial (GRS) peak systolic strain were assessed on cine SSFP data using commercially available FT algorithms and prototype DRA-based algorithms. STE was applied as standard of reference for accuracy, precision and intra-/interobserver reproducibility testing. DRA showed narrower limits of agreement compared to STE for GLS (-4.0 [-0.9,-7.9]) and GCS (-5.1 [1.1,-11.2]) than FT (3.2 [11.2,-4.9]; 3.8 [13.9,-6.3], respectively). While both DRA and FT demonstrated significant differences to STE for GLS and GCS (all p<0.001), only DRA correlated significantly to STE for GLS (r=0.47; p=0.006). However, good correlation was demonstrated between MR techniques (GLS:r=0.74; GCS:r=0.80; GRS:r=0.45, all p<0.05). Comparing DRA with FT, intra-/interobserver coefficient of variance was lower (1.6 %/3.2 % vs. 6.4 %/5.7 %) and intraclass-correlation coefficient was higher. DRA GCS and GRS data presented zero variability for repeated observations. DRA is an automated method that allows myocardial deformation assessment with superior reproducibility compared to FT. (orig.)

  16. Intraoperative Right Ventricular Fractional Area Change Is a Good Indicator of Right Ventricular Contractility: A Retrospective Comparison Using Two- and Three-Dimensional Echocardiography.

    Science.gov (United States)

    Imada, Tatsuyuki; Kamibayashi, Takahiko; Ota, Chiho; Carl Shibata, Sho; Iritakenishi, Takeshi; Sawa, Yoshiki; Fujino, Yuji

    2015-08-01

    Intraoperative two-dimensional echocardiography is technically challenging, given the unique geometry of the right ventricle (RV). It was hypothesized that the RV fractional area change (RVFAC) could be used as a simple method to evaluate RV function during surgery. Therefore, the correlation between the intraoperative RVFAC and the true right ventricular ejection fraction (RVEF), as measured using newly developed three-dimensional (3D) analysis software, was evaluated. Retrospective study. University hospital. Patients who underwent cardiac surgery with transesophageal echocardiography monitoring between March 2014 and June 2014. None. Sixty-two patients were included in this study. After the exclusion of poor imaging data and patients with arrhythmias, 54 data sets were analyzed. RVFAC was measured by one anesthesiologist during surgery, and full-volume 3D echocardiographic data were recorded simultaneously. The 3D data were analyzed postoperatively using off-line 3D analysis software by a second anesthesiologist, who was blinded to the RVFAC results. The mean RVFAC was 38.8% ± 8.7%, the mean RVEF was 41.4% ± 8.3%, and there was a good correlation between the RVFAC and the RVEF (r(2) = 0.638; prights reserved.

  17. Inducing fluorescence of uranyl acetate as a dual-purpose contrast agent for correlative light-electron microscopy with nanometre precision.

    Science.gov (United States)

    Tuijtel, Maarten W; Mulder, Aat A; Posthuma, Clara C; van der Hoeven, Barbara; Koster, Abraham J; Bárcena, Montserrat; Faas, Frank G A; Sharp, Thomas H

    2017-09-05

    Correlative light-electron microscopy (CLEM) combines the high spatial resolution of transmission electron microscopy (TEM) with the capability of fluorescence light microscopy (FLM) to locate rare or transient cellular events within a large field of view. CLEM is therefore a powerful technique to study cellular processes. Aligning images derived from both imaging modalities is a prerequisite to correlate the two microscopy data sets, and poor alignment can limit interpretability of the data. Here, we describe how uranyl acetate, a commonly-used contrast agent for TEM, can be induced to fluoresce brightly at cryogenic temperatures (-195 °C) and imaged by cryoFLM using standard filter sets. This dual-purpose contrast agent can be used as a general tool for CLEM, whereby the equivalent staining allows direct correlation between fluorescence and TEM images. We demonstrate the potential of this approach by performing multi-colour CLEM of cells containing equine arteritis virus proteins tagged with either green- or red-fluorescent protein, and achieve high-precision localization of virus-induced intracellular membrane modifications. Using uranyl acetate as a dual-purpose contrast agent, we achieve an image alignment precision of ~30 nm, twice as accurate as when using fiducial beads, which will be essential for combining TEM with the evolving field of super-resolution light microscopy.

  18. Extending Local Canonical Correlation Analysis to Handle General Linear Contrasts for fMRI Data

    Directory of Open Access Journals (Sweden)

    Mingwu Jin

    2012-01-01

    Full Text Available Local canonical correlation analysis (CCA is a multivariate method that has been proposed to more accurately determine activation patterns in fMRI data. In its conventional formulation, CCA has several drawbacks that limit its usefulness in fMRI. A major drawback is that, unlike the general linear model (GLM, a test of general linear contrasts of the temporal regressors has not been incorporated into the CCA formalism. To overcome this drawback, a novel directional test statistic was derived using the equivalence of multivariate multiple regression (MVMR and CCA. This extension will allow CCA to be used for inference of general linear contrasts in more complicated fMRI designs without reparameterization of the design matrix and without reestimating the CCA solutions for each particular contrast of interest. With the proper constraints on the spatial coefficients of CCA, this test statistic can yield a more powerful test on the inference of evoked brain regional activations from noisy fMRI data than the conventional t-test in the GLM. The quantitative results from simulated and pseudoreal data and activation maps from fMRI data were used to demonstrate the advantage of this novel test statistic.

  19. Comparison of Quantitative Wall Motion Analysis and Strain For Detection Of Coronary Stenosis With Three-Dimensional Dobutamine Stress Echocardiography

    Science.gov (United States)

    Parker, Katherine M.; Clark, Alexander P.; Goodman, Norman C.; Glover, David K.; Holmes, Jeffrey W.

    2015-01-01

    Background Quantitative analysis of wall motion from three-dimensional (3D) dobutamine stress echocardiography (DSE) could provide additional diagnostic information not available from qualitative analysis. In this study we compare the effectiveness of 3D fractional shortening (3DFS), a measure of wall motion computed from 3D echocardiography (3DE), to strain and strain rate measured with sonomicrometry for detecting critical stenoses during DSE. Methods Eleven open-chest dogs underwent DSE both with and without a critical stenosis. 3DFS was measured from 3DE images acquired at peak stress. 3DFS was normalized by subtracting average 3DFS during control peak stress (Δ3DFS). Strains in the perfusion defect (PD) were measured from sonomicrometry, and PD size and location were measured with microspheres. Results A Δ3DFS abnormality indicated the presence of a critical stenosis with high sensitivity and specificity (88% and 100%, respectively), and Δ3DFS abnormality size correlated with PD size (R2=0.54). The sensitivity and specificity for Δ3DFS was similar to that for area strain (88%, 100%) and circumferential strain and strain rate (88%, 92% and 88%, 86%, respectively), while longitudinal strain and strain rate were less specific. Δ3DFS correlated significantly with both coronary flow reserve (R2=0.71) and PD size (R2=0.97), while area strain correlated with PD size only (R2=0.67), and other measures were not significantly correlated with flow reserve or PD size. Conclusion Quantitative wall motion analysis using Δ3DFS is effective for detecting critical stenoses during DSE, performing similarly to 3D strain, and provides potentially useful information on the size and location of a perfusion defect. PMID:24815588

  20. Is epicardial adipose tissue, another measure of central obesity, correlated with erectile dysfunction?

    Directory of Open Access Journals (Sweden)

    Chih-Wei Tsao

    2016-01-01

    Full Text Available Background: This study investigated the correlation between epicardial adipose tissue (EAT, a measure of central obesity, and sexual function in males with vasculogenic erectile dysfunction (ED. Materials and Methods: The study was a cross-sectional study of selected males with ED aged <75 years who attended the Urology Outpatient Department of Tri-Service General Hospital. Sixty subjects were included in the study, which employed biochemical data, anthropometric indexes, echocardiography, and questionnaires. Biochemical lipid profiles and associated inflammation markers were recorded. The anthropometric indexes included general and central obesity and bioelectrical impedance analysis. Echocardiography results were assessed by a single experienced cardiologist and included epicardial and pericardial fat thickness measurements. Sexual function was evaluated using the International Index of Erectile Function-5 (IIEF-5 score. Results: According to the analysis of variance and multivariate logistic regression, only the erectile hardness score (EHS was statistically positively correlated with the IIEF-5 score. All other anthropometric indexes and echocardiography parameters, including EAT thickness, pericardial adipose tissue thickness, and ejection fraction (EF, were not significantly associated with sexual function. Conclusions: Only EHS was statistically associated with sexual function in the male subjects with ED. The anthropometric indexes and EAT thickness, a measure of central obesity, were not significantly correlated with sexual function in the male patients with ED.

  1. Correlative Study of Angiogenesis and Dynamic Contrast-Enhanced Magnetic Resonance Imaging Features of Hepatocellular Carcinoma

    International Nuclear Information System (INIS)

    Wang, B.; Gao, Z.Q.; Yan, X.

    2005-01-01

    Purpose: To explore the correlation between contrast-enhancement patterns on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and angiogenesis by analyzing microvessel density (MVD), vascular endothelial growth factor (VEGF), and P53 protein expression in hepatocellular carcinoma (HCC). Material and Methods: MRI was performed with a GE Signa 5T MR scanner using SE and FMPSPGR sequences in 30 patients (38 lesions) during the period October 1998 to March 2000. All had histopathologically proven HCC. MR images were reviewed/analyzed retrospectively. The 30 patients were between 35 and 65 years of age. SE T1WI, PDWI, and T2WI were acquired initially. The FMPSPGR sequence was acquired in the same position. The DCE-MRI was performed in the arterial, portal vein, and delay phase after a bolus injection of Gd-DTPA. The specimens were stained immunohistochemically for CD34, VEGF, and P53. MVD was highlighted by anti-CD34 antibody staining. The enhancement features of HCC lesions were studied correlatively with the tumor MVD, VEGF, and P53 expression at protein level. Results: In the arterial phase, the results showed that MVD of HCC in the high-enhancement group (229.76±80.96) was higher than that in the equal-enhancement (173.09±61.38) and low-enhancement groups (153.00±108.58) (P <0.01, respectively). VEGF expression of HCC in the high-enhancement group (68.42%) was higher than that in the equal-enhancement (36.36%) and low-enhancement groups (38.89%) (P <0.05, respectively). In the portal vein phase, MVD of HCC in the enhancement group (259.80±93.30) was higher than that in the non-enhancement group (178.64±92.65) (P <0.05). No significant correlation was found between VEGF expression and the enhancement feature in the portal vein phase. In the delay phase, MVD of HCC in the ring-enhancement group (269.06±57.89) was significantly higher than that in the non-ring-enhancement group (144.10±88.90) (P <0.01). There was a significant difference in VEGF

  2. Assessment of right ventricular systolic function by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjærgaard, Jesper

    2012-01-01

    This thesis summarizes a series of studies performed in order to assess the clinical usefulness of a novel echocardiographic technology that allows non-invasive assessment of regional right ventricular myocardial velocities and deformation: tissue Doppler echocardiography. While the technology...... is a promising tool for improving our understanding of right ventricular hemodynamics, several aspects of the technology must be evaluated. The accuracy and reproducibility of the technology is evaluated in vitro, and normal values, impact of changes in loading of the right ventricle, response to exercise...... on right ventricular hemodynamics: pulmonary embolism, Arrhythmogenic right ventricular cardiomyopathy and pulmonary regurgitation, the latter in an animal model. The conclusions of the thesis are: Color tissue Doppler echocardiography accurately measures velocities, SR and strain in vitro. No systematic...

  3. Prognostic Value of Echocardiography in Hypertensive Versus Nonhypertensive Participants From the General Population

    DEFF Research Database (Denmark)

    Modin, Daniel; Biering-Sørensen, Sofie Reumert; Mogelvang, Rasmus

    2018-01-01

    Hypertension may be the most significant cardiovascular risk factor. Few studies have assessed the prognostic value of echocardiography in hypertensive individuals. This study examines the incremental prognostic value of adding echocardiographic parameters to established risk factors in individuals...... of echocardiography in predicting cardiovascular outcomes in the general population is altered by hypertension. In hypertensive individuals, left ventricular mass index added incremental prognostic value in addition to established risk factors. In nonhypertensive individuals, global longitudinal strain added...

  4. Comparision the value of detecting myocardial viability between low dose dobutamine stress MRI and echocardiography

    International Nuclear Information System (INIS)

    He Yi; Zhang Zhaoqi; Yu Wei; Miao Cuilian; Zhao Yike; Yan Zixu

    2006-01-01

    Objective: To Compare the diagnostic value between low dose dobutamine stress transthrotic echocardiography and low dose dobutamine stress MRI in detecting myocardial viability of chronic myocardial infarction. Methods: Rest and low dose dobutamine (5, 10 μg·kg -1 ·min -1 ) stress transthrotic echocardiography and cine-MRI were performed in 30 patients with chronic myocardial infarction. 24 patients underwent successful revascularization and 10 of them underwent another rest cine-MRI study to assess segmental myocardial functional recovery. Left ventricular were divided into 16 segments, the criteria of viability in different techniques is: MRI: dobutamine induced systolic wall thickening was ≥2 mm in akinetic or diskinetic segments at rest; Echocardiography: wall motion score reduced at least 1 after dobutamine stress in akinetic or' diskinetic segments at rest. Results: One hundren and eight segments showed wall motion abnormalities of 30 patients, 65 and 56 segments shows positive reaction, 43 and 52 segments shows negativereaction in MRI and echocardiography after dobutamine stress respectively. Kappa value of the two techniques is 0.75, concordance in both techniques is 88%. Twenty-four segments showed functional recovery, 14 segments remained dysfunction 3-6 months after revascularization, the sensitivity, specificity and accuracy of detecting myocardial viability in chronic myocardial infarction in MRI and echocardiography is 95.8% vs 79.2% (P>0.05), 85.7% vs 85.7% (P>0.05), 92.1% vs 81.6% (P>0.05) respectively. The sensitivity and accuracy of MRI is a little higher. Conclusion: The ability of detecting myocardial viability by both low dose dobutamine stress transthrotic echocardiography and low dose dobutamine stress MRI is similer, the sensitivity and accuracy of MRI is a little higher. (authors)

  5. Intraoperative Two- and Three-Dimensional Transesophageal Echocardiography in Combined Myectomy-Mitral Operations for Hypertrophic Cardiomyopathy.

    Science.gov (United States)

    Nampiaparampil, Robert G; Swistel, Daniel G; Schlame, Michael; Saric, Muhamed; Sherrid, Mark V

    2018-03-01

    Transesophageal echocardiography is essential in guiding the surgical approach for patients with obstructive hypertrophic cardiomyopathy. Septal hypertrophy, elongated mitral valve leaflets, and abnormalities of the subvalvular apparatus are prominent features, all of which may contribute to left ventricular outflow tract obstruction. Surgery aims to alleviate the obstruction via an extended myectomy, often with an intervention on the mitral valve and subvalvular apparatus. The goal of intraoperative echocardiography is to assess the anatomic pathology and pathophysiology in order to achieve a safe intraoperative course and a successful repair. This guide summarizes the systematic evaluation of these patients to determine the best surgical plan. Copyright © 2017 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  6. Correlation between right ventricular T1 mapping and right ventricular dysfunction in non-ischemic cardiomyopathy.

    Science.gov (United States)

    Jellis, Christine L; Yingchoncharoen, Teerapat; Gai, Neville; Kusunose, Kenya; Popović, Zoran B; Flamm, Scott; Kwon, Deborah

    2018-01-01

    Right ventricular (RV) fibrosis is increasingly recognized as the underlying pathological substrate in a variety of clinical conditions. We sought to employ cardiac magnetic resonance (CMR) techniques of strain imaging and longitudinal relaxation time (T 1 ) mapping to better examine the relationship between RV function and structure. Our aim was to initially evaluate the feasibility of these techniques to evaluate the right ventricle. We then sought to explore the relationship between RV function and underlying fibrosis, along with examining the evolution of RV remodeling according to the amount of baseline fibrosis. Echocardiography was performed in 102 subjects with non-ischemic cardiomyopathy. Right ventricular parameters were assessed including: fractional area change (FAC) and longitudinal strain. The same cohort underwent CMR. Post-contrast T 1 mapping was performed as a marker of fibrosis with a Look-Locker technique using inversion recovery imaging. Mid-ventricular post-contrast T 1 values of the RV free wall, RV septum and lateral LV were calculated using prototype analysis software. Biventricular volumetric data including ejection fraction was measured by CMR using a cine short axis stack. CMR strain analysis was also performed to assess 2D RV longitudinal and radial strain. Simultaneous biochemical and anthropometric data were recorded. Subjects were followed over a median time of 29 months (IQR 20-37 months) with echocardiography to evaluate temporal change in RV FAC according to baseline post-contrast T 1 values. Longitudinal data analysis was performed to adjust for patient loss during follow-up. Subjects (62% men, 51 ± 15 years) had mild to moderately impaired global RV systolic function (RVEF = 39 ± 15%; RVEDV = 187 ± 69 ml; RVESV = 119 ± 68 ml) and moderate left ventricular dysfunction at baseline (LVEF 30 ± 17%). Good correlation was observed between mean LV and RV post-contrast T 1 values (r = 0.652, p

  7. TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN PATIENTS WITH CEREBRAL ISCHEMIA

    Directory of Open Access Journals (Sweden)

    Kavian Ghandehari

    2010-12-01

    Full Text Available Abstract INTRODUCTION: Transesophageal echocardiography (TEE is superior to Transthoracic echocardiography (TTE in detection of atrial septal defects and aneurysm, aortic atheroma, left atrial thrombus and mitral valve abnormalities. TEE is indicated in young adults with cryptogenic ischemic stroke who are suspected of having cardioembolic mechanism despite non-diagnostic TTE. METHODS: A prospective clinical study was conducted in patients with ischemic stroke or TIA who had TTE done in Ghaem hospital, Mashhad during 2006-2007. Ischemic cerebrovascular events were detected by stroke neurologist. TEE was performed with VIPI3/GE device, USA and a 7 MHz transesophageal probe by an echocardiologist. Patients who did not have TTE before TEE were excluded. Comparison of TEE to TTE results was performed by the echocardiologist and stroke neurologist in each patient. Influence of TEE on therapeutic decisions in each patient was evaluated. RESULTS: Forty-seven patients (20 females, 27 males with a mean age of 42.6±7.3 years were studied. Cardiac and aortic abnormalities were detected in TEE of 35 cases (35/47; 74% with ischemic cerebrovascular events. Cardiac abnormalities of 17 cases (36% were only detectable by TEE. These seventeen cases included 7 patients with PFO, 1 case with ASD, 6 cases with aortic atheroma and 2 patients with clot in the left atrium. Comparing the preventive stroke strategies before and after TEE revealed that it was changed only in two cases (2/47; 4.3% due to performing TEE. These included one patient with a small high-risk PFO and another case with dehicense of mechanical mitral valve. CONCLUSION: TEE revealed cardiac or aortic abnormalities in one-third of the patients with cerebral ischemia and has not been detected by TEE previously. The influence of TEE in therapeutic decisions of patients with ischemic cerebrovascular events is very low.         Keywords: Transesophageal echocardiography, Stroke, Transient Ischemic

  8. Correlation between model observers in uniform background and human observers in patient liver background for a low-contrast detection task in CT

    Science.gov (United States)

    Gong, Hao; Yu, Lifeng; Leng, Shuai; Dilger, Samantha; Zhou, Wei; Ren, Liqiang; McCollough, Cynthia H.

    2018-03-01

    Channelized Hotelling observer (CHO) has demonstrated strong correlation with human observer (HO) in both single-slice viewing mode and multi-slice viewing mode in low-contrast detection tasks with uniform background. However, it remains unknown if the simplest single-slice CHO in uniform background can be used to predict human observer performance in more realistic tasks that involve patient anatomical background and multi-slice viewing mode. In this study, we aim to investigate the correlation between CHO in a uniform water background and human observer performance at a multi-slice viewing mode on patient liver background for a low-contrast lesion detection task. The human observer study was performed on CT images from 7 abdominal CT exams. A noise insertion tool was employed to synthesize CT scans at two additional dose levels. A validated lesion insertion tool was used to numerically insert metastatic liver lesions of various sizes and contrasts into both phantom and patient images. We selected 12 conditions out of 72 possible experimental conditions to evaluate the correlation at various radiation doses, lesion sizes, lesion contrasts and reconstruction algorithms. CHO with both single and multi-slice viewing modes were strongly correlated with HO. The corresponding Pearson's correlation coefficient was 0.982 (with 95% confidence interval (CI) [0.936, 0.995]) and 0.989 (with 95% CI of [0.960, 0.997]) in multi-slice and single-slice viewing modes, respectively. Therefore, this study demonstrated the potential to use the simplest single-slice CHO to assess image quality for more realistic clinically relevant CT detection tasks.

  9. Extracting and analyzing ejection fraction values from electronic echocardiography reports in a large health maintenance organization.

    Science.gov (United States)

    Xie, Fagen; Zheng, Chengyi; Yuh-Jer Shen, Albert; Chen, Wansu

    2017-12-01

    The left ventricular ejection fraction value is an important prognostic indicator of cardiovascular outcomes including morbidity and mortality and is often used clinically to indicate severity of heart disease. However, it is usually reported in free-text echocardiography reports. We developed and validated a computerized algorithm to extract ejection fraction values from echocardiography reports and applied the algorithm to a large volume of unstructured echocardiography reports between 1995 and 2011 in a large health maintenance organization. A total of 621,856 echocardiography reports with a description of ejection fraction values or systolic functions were identified, of which 70 percent contained numeric ejection fraction values and the rest (30%) were text descriptions explicitly indicating the systolic left ventricular function. The 12.1 percent (16.0% for male and 8.4% for female) of these extracted ejection fraction values are <45 percent. Validation conducted based on a random sample of 200 reports yielded 95.0 percent sensitivity and 96.9 percent positive predictive value.

  10. The Role of Echocardiography and Intracardiac Exploration in the Evaluation of Candidacy for Biventricular Repair in Patients With Borderline Left Heart Structures.

    Science.gov (United States)

    Mery, Carlos M; Nieto, R Michael; De León, Luis E; Morris, Shaine A; Zhang, Wei; Colquitt, John L; Adachi, Iki; Kane, Lauren C; Heinle, Jeffrey S; McKenzie, E Dean; Fraser, Charles D

    2017-03-01

    Predictors for single ventricle palliation (SVP) or successful biventricular repair (BVR) in patients with borderline left-side heart structures are not well defined. The goal was to evaluate the role of echocardiography and intracardiac exploration in determining feasibility of BVR. All neonates surgically treated from 1995 to 2015 with mitral valve (MV), aortic valve, or left ventricle end-diastolic dimension z score of -2 or less for whom management was controversial were included. Data were analyzed using Fisher's exact test, Kruskal-Wallis test, and Kaplan-Meier analysis. The cohort consisted of 42 patients: 7 SVP (17%) and 35 BVR (83%). Median follow-up was 7 years (range, 6 months to 18 years). Intracardiac exploration was performed in 29 patients (69%). There was poor correlation between echocardiographic and intraoperative MV measurements (intraclass correlation coefficient 0.14). Preoperative echocardiography significantly underestimated MV size in 14 patients (54%). Two BVR patients were converted to SVP, and 4 (including 1 converted patient) had cardiac-related deaths. All patients with MV greater than 8 mm on preoperative echocardiography had successful BVR. An intraoperative MV less than 8 mm and an abnormal subvalvar apparatus was present in 5 of 6 SVP (83%) and 3 of 3 (100%) failed BVR patients who had intracardiac exploration, and in only 1 of 20 successful BVR patients (5%) who had an intracardiac exploration. The decision to proceed to BVR in patients with borderline left-side heart structures should not rely strictly on echocardiographic measurements. Intracardiac exploration of the MV and subvalvar apparatus is useful before committing a patient to SVP. Patients with low MV z scores, especially those with a normal subvalvar apparatus, may undergo BVR with good outcomes. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Is epicardial adipose tissue, assessed by echocardiography, a reliable method for visceral adipose tissue prediction?

    Science.gov (United States)

    Silaghi, Alina Cristina; Poantă, Laura; Valea, Ana; Pais, Raluca; Silaghi, Horatiu

    2011-03-01

    Epicardial adipose tissue is an ectopic fat storage at the heart surface in direct contact with the coronary arteries. It is considered a metabolically active tissue, being a local source of pro-inflammatory factors that contribute to the pathogenesis of coronary artery disease. The AIM of our study was to establish correlations between echocardiographic assessment of epicardial adipose tissue and anthropometric and ultrasound measurements of the central and peripheral fat depots. The study was conducted on 22 patients with or without coronaropathy. Epicardial adipose tissue was measured using Aloka Prosound α 10 machine with a 3.5-7.5 MHz variable-frequency transducer and subcutaneous and visceral fat with Esaote Megas GPX machine and 3.5-7.5 MHz variable frequency transducer. Epicardial adipose tissue measured by echocardiography is correlated with waist circumference (p < 0.05), visceral adipose tissue thickness measured by ultrasonography (US) and is not correlated with body mass index (p = 0.315), hip and thigh circumference or subcutaneous fat thickness measured by US. Our study confirms that US assessment of epicardial fat correlates with anthropometric and US measurements of the central fat, representing an indirect but reliable marker of the visceral fat.

  12. Detection of heart disease by open access echocardiography: a retrospective analysis of general practice referrals

    Science.gov (United States)

    Chambers, John; Kabir, Saleha; Cajeat, Eric

    2014-01-01

    Background Heart disease is difficult to detect clinically and it has been suggested that echocardiography should be available to all patients with possible cardiac symptoms or signs. Aim To analyse the results of 2 years of open access echocardiography for the frequency of structural heart disease according to request. Design and setting Retrospective database analysis in a teaching hospital open access echocardiography service. Method Reports of all open access transthoracic echocardiograms between January 2011 and December 2012 were categorised as normal, having minor abnormalities, or significant abnormalities according to the indication. Results There were 2343 open access echocardiograms performed and there were significant abnormalities in 29%, predominantly valve disease (n = 304, 13%), LV systolic dysfunction (n = 179, 8%), aortic dilatation (n = 80, 3%), or pulmonary hypertension (n = 91, 4%). If echocardiography had been targeted at a high-risk group, 267 with valve disease would have been detected (compared to 127 with murmur alone) and 139 with LV systolic dysfunction (compared to 91 with suspected heart failure alone). Most GP practices requested fewer than 10 studies, but 6 practices requested over 70 studies. Conclusion Open access echocardiograms are often abnormal but structural disease may not be suspected from the clinical request. Uptake by individual practices is patchy. A targeted expansion of echocardiography in patients with a high likelihood of disease is therefore likely to increase the detection of clinically important pathology. PMID:24567615

  13. Prosthesis-patient mismatch after transcatheter aortic valve implantation: impact of 2D-transthoracic echocardiography versus 3D-transesophageal echocardiography.

    Science.gov (United States)

    da Silva, Cristina; Sahlen, Anders; Winter, Reidar; Bäck, Magnus; Rück, Andreas; Settergren, Magnus; Manouras, Aristomenis; Shahgaldi, Kambiz

    2014-12-01

    To investigate the role of 2D-transthoracic echocardiography (2D-TTE) and 3D-transesophageal echocardiography (3D-TEE) in the determination of aortic annulus size prior transcatheter aortic valve implantation (TAVI) and its' impact on the prevalence of patient prosthesis mismatch (PPM). Echocardiography plays an important role in measuring aortic annulus dimension in patients undergoing TAVI. This has great importance since it determines both eligibility for TAVI and selection of prosthesis type and size, and can be potentially important in preventing an inadequate ratio between the prosthetic valvular orifice and the patient's body surface area, concept known as prosthesis-patient mismatch (PPM). A total of 45 patients were studied pre-TAVI: 20 underwent 3D-TEE (men/women 12/8, age 84.8 ± 5.6) and 25 2D-TTE (men/women 9/16, age 84.4 ± 5.4) in order to measure aortic annulus diameter. The presence of PPM was assessed before hospital discharge and after a mean period of 3 months. Moderate PPM was defined as indexed aortic valve area (AVAi) ≤ 0.85 cm(2)/m(2) and severe PPM as AVAi 3D-TEE and 2D-TTE respectively p value = n.s) and severe PPM occurred in 10 % of the patients who underwent 3D-TEE and in 20 % in those with 2D-TTE (p value = n.s). The echocardiographic evaluation 3 months post-TAVI showed 25 % moderate PPM in the 3D-TEE group compared with 24 % in the 2D-TTE group (p value = n.s) and no cases of severe PPM in the 3DTEE group comparing to 20 % in the 2D-TTE group (p = 0.032). Our results indicate a higher incidence of severe PPM in patients who performed 2DTTE compared to those performing 3DTEE prior TAVI. This suggests that the 3D technique should replace the 2DTTE analysis when investigating the aortic annulus diameter in patients undergoing TAVI.

  14. Echocardiography-based hemodynamic management of left ventricular diastolic dysfunction: a feasibility and safety study.

    Science.gov (United States)

    Shillcutt, Sasha K; Montzingo, Candice R; Agrawal, Ankit; Khaleel, Maseeha S; Therrien, Stacey L; Thomas, Walker R; Porter, Thomas R; Brakke, Tara R

    2014-11-01

    Patients with left ventricular diastolic dysfunction (LVDD) are at increased risk of postoperative adverse events. The primary aim of this study was to evaluate the safety and feasibility of using echocardiography-guided hemodynamic management (EGHEM) during surgery in subjects with LVDD compared to conventional management. The feasibility of using echocardiography to direct a treatment algorithm and clinical outcomes were compared for safety between groups. Subjects were screened for LVDD by preoperative transthoracic echocardiography (TTE) and randomized to the conventional or EGHEM group. Subjects in EGHEM received hemodynamic management based on left ventricular filling patterns on transesophageal echocardiography (TEE). Primary outcomes measured were the feasibility to obtain TEE images and follow a TEE-based treatment algorithm. Safety outcomes also compared the following clinical differences between groups: length of hospitalization, incidence of atrial fibrillation, congestive heart failure (CHF), myocardial infarction, cerebrovascular accident, transient ischemic attack and renal failure measured 30 days postoperatively. Population consisted of 28 surgical subjects (14 in conventional group and 14 in EGHEM group). Mean subject age was 73.4 ± 6.7 years (36% male) in conventional group and 65.9 ± 14.4 years (36% male) in EGHEM group. Procedures included orthopedic (conventional = 29%, EGHEM 36%), general (conventional = 50%, EGHEM = 36%), vascular (conventional = 7%, EGHEM = 21%), and thoracic (conventional = 14%, EGHEM = 7%). There was no statistically significant difference in adverse clinical events between the 2 groups. The EGHEM group had less CHF, atrial fibrillation, and shorter length of stay. Echocardiography-guided hemodynamic management of patients with LVDD during surgery is feasible and may be a safe alternative to conventional management. © 2014, Wiley Periodicals, Inc.

  15. Trends in pediatric echocardiography and the yield for congenital heart disease in a major cardiac referral hospital in Cameroon.

    Science.gov (United States)

    Nkoke, Clovis; Balti, Eric; Menanga, Alain; Dzudie, Anastase; Lekoubou, Alain; Kingue, Samuel; Kengne, Andre Pascal

    2017-01-01

    Congenital heart disease (CHD) is a common condition in children in Sub-Saharan Africa (SSA), where it is associated with poor outcomes. Diagnosis of CHD in SSA depends essentially on echocardiography, which is available only in few urban referral centers. Our aim was to assess time changes in the pattern of referral for pediatric echocardiography and the subsequent diagnosis of structural CHD in a major SSA city. All pediatric echocardiography performed between 2004 and 2013 at the echocardiography laboratory of the Yaounde General Hospital were reviewed. The primary indication of the study and the presence of structural CHD were recorded. Between 2004 and 2013, 9,390 echocardiograms were performed and 834 (8.9%) children aged 1 day to 15 years underwent echocardiography at the center, and 227 (27.2%) cases of definite structural CHD were diagnosed, with 123 (54.2%) in boys. The most frequent indications for echocardiography were heart murmurs (40%) and the suspicion of CHD (37.4%). The commonest CHD was ventricular septal defect (VSD) (30%) with tetralogy of Fallot being the most frequent cyanotic heart lesion (5.3%). The proportion of pediatric echocardiography decreased from 13.3% in 2004-2005 to 6.1% in 2012-2013 (P=0.001) but not in a linear fashion (P=0.072 for linear trend).The diagnosis of structural CHD increased from 25.1% in 2004-2005 to 27.1% in 2012-2013. This increase however was non-significant (P=0.523) and did not follow a linear trend (P=0.230). The pattern of referral for pediatric echocardiography at this center has changed over time, but diagnosis of structural CHD has remained the same. Improving access to this diagnostic procedure and subsequent treatment of diagnosed CHD will help improving the outcome of the disease in this setting.

  16. Comparison of indium-111 platelet scintigraphy and two-dimensional echocardiography in the diagnosis of left ventricular thrombi

    International Nuclear Information System (INIS)

    Ezekowitz, M.D.; Wilson, D.A.; Smith, E.O.; Burow, R.D.; Harrison, L.H. Jr.; Parker, D.E.; Elkins, R.C.; Peyton, M.; Taylor, F.B.

    1982-01-01

    In a study comparing indium-111 platelet scintigraphy and two-dimensional echocardiography as methods of identifying left ventricular thrombi, the results obtained with both techniques were verified at surgery or autopsy in 53 patients-34 with left ventricular aneurysms, and 19 with mitral-valve disease. Left ventricular thrombi were found at surgery or autopsy in 14 of the patients with aneurysms and in none of those with mitral-valve disease. Thirteen of 53 echocardiograms (25%) were technically inadequate and excluded from the analysis. In the group with aneurysms, the sensitivity of scintigraphy in detecting thrombi was 71%, and that of echocardiography was 77%. The specificity of scintigraphy was 100%, and that of echocardiography was 93%. We conclude that indium-111 platelet scintigraphy and two-dimensional echocardiography have useful and complementary roles in the detection of left ventricular thrombi. Both these noninvasive techniques can be used to monitor therapy

  17. Correlation between human observer performance and model observer performance in differential phase contrast CT

    International Nuclear Information System (INIS)

    Li, Ke; Garrett, John; Chen, Guang-Hong

    2013-01-01

    Purpose: With the recently expanding interest and developments in x-ray differential phase contrast CT (DPC-CT), the evaluation of its task-specific detection performance and comparison with the corresponding absorption CT under a given radiation dose constraint become increasingly important. Mathematical model observers are often used to quantify the performance of imaging systems, but their correlations with actual human observers need to be confirmed for each new imaging method. This work is an investigation of the effects of stochastic DPC-CT noise on the correlation of detection performance between model and human observers with signal-known-exactly (SKE) detection tasks.Methods: The detectabilities of different objects (five disks with different diameters and two breast lesion masses) embedded in an experimental DPC-CT noise background were assessed using both model and human observers. The detectability of the disk and lesion signals was then measured using five types of model observers including the prewhitening ideal observer, the nonprewhitening (NPW) observer, the nonprewhitening observer with eye filter and internal noise (NPWEi), the prewhitening observer with eye filter and internal noise (PWEi), and the channelized Hotelling observer (CHO). The same objects were also evaluated by four human observers using the two-alternative forced choice method. The results from the model observer experiment were quantitatively compared to the human observer results to assess the correlation between the two techniques.Results: The contrast-to-detail (CD) curve generated by the human observers for the disk-detection experiments shows that the required contrast to detect a disk is inversely proportional to the square root of the disk size. Based on the CD curves, the ideal and NPW observers tend to systematically overestimate the performance of the human observers. The NPWEi and PWEi observers did not predict human performance well either, as the slopes of their CD

  18. Exercise and rest Tl-201 myocardial SPECT, and low dose dobutamine echocardiography to assess myocardial viability in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Toyama, Takuji; Ishida, Yoshio; Shimonagata, Tsuyoshi; Kawano, Shigeo; Beppu, Shintaro; Nishimura, Tsunehiko.

    1994-01-01

    To evaluate viability of infarcted myocardium, findings of Tl-201 myocardial SPECT were compared with those of low-dose dobutamine (DOB) echocardiography. The subjects were 19 patients with myocardial infarction (23 infarcted zones), consisting of 16 men and 3 women. Findings on myocardial SPECT were classified as evidence of myocardial viability (14 zones, Group A) and no evidence of myocardial viability (9 zones, Group B). For both groups, wall motion and regional % uptake (%UP) were obtained. DOB echocardiography revealed an improvement in 5 of 8 akinesis zones in Group A. In addition, one other zone was found improved by follow-up examination. Six hypokinesis zones were all found improved on DOB echocardiography. Out of a total of 14 akinesis or hypokinesis zones, 11 (79%) showed improvement on DOB echocardiography in Group A. In Group B, all akinesis zones remained unchanged on DOB echocardiography, although one zone was improved by follow-up examination. In 11 zones in which wall motion was improved on DOB echocardiography, %UT was increased by an average of 58% on 4 hr-delayed images and 70% on resting images. The corresponding figures for 12 zones which did not improve on DOB echocardiography were 49% and 50% on the average, respectively. In conclusion, low-dose DOB echocardiography appeared to reflect viability of severely infarcted myocardium, although it had a slightly lower sensitivity than convensional Tl-201 myocardial SPECT in its ability to detect. (N.K.)

  19. VALIDATION OF MITRAL VALVE ANNULUS DIMENSIONS MEASURED BY 2D TRANS-THORACIC ECHOCARDIOGRAPHY WITH GOLD STANDARD DIRECT INTRA-OPERATIVE MEASUREMENT

    OpenAIRE

    Praveen; Yadav; Ankur; Saket; Kaushal

    2014-01-01

    CONTEXT: Precise estimation of Mitral valve annulus dimensions preoperatively through Echocardiography is of paramount importance in replacement/repair surgeries. However a frequent disagreement was experienced between anticipated size of prosthetic valve based on echocardiography and actual valve size. This fact encouraged the authors to validate the measurements through echocardiography with gold-standard direct intra operative measurement. AIM: To compare the mitral val...

  20. Effects of Minimum and Maximum Doses of Furosemide on Fractional Shortening Parameter in Echocardiography of the New Zealand White Rabbit

    Directory of Open Access Journals (Sweden)

    Roham Vali, Mohammad Nasrollahzadeh Masouleh* and Siamak Mashhady Rafie1

    2013-04-01

    Full Text Available There is no data on the effect of maximum and minimum doses of furosemide on heart's work performance and amount of fractional shortening (FS in echocardiography of rabbit. This study was designed to validate probability of the mentionable effect. Twenty-four healthy female New Zealand white rabbits were divided into four equal groups. Maximum and minimum doses of furosemide were used for the first and second groups and the injection solution for the third and fourth groups was sodium chloride 0.9% which had the same calculated volumes of furosemide for the first two groups, respectively. The left ventricle FS in statutory times (0, 2, 5, 15, 30 minutes was determined by echocardiography. Measurements of Mean±SD, maximum and minimum amounts for FS values in all groups before injection and in statutory times were calculated. Statistical analysis revealed non-significant correlation between the means of FS. The results of this study showed that furosemide can be used as a diuretic agent for preparing a window approach in abdominal ultrasonography examination with no harmful effect on cardiac function.

  1. Correlation between electrical and hemodynamic responses during visual stimulation with graded contrasts

    Science.gov (United States)

    Si, Juanning; Zhang, Xin; Li, Yuejun; Zhang, Yujin; Zuo, Nianming; Jiang, Tianzi

    2016-09-01

    Brain functional activity involves complex cellular, metabolic, and vascular chain reactions, making it difficult to comprehend. Electroencephalography (EEG) and functional near infrared spectroscopy (fNIRS) have been combined into a multimodal neuroimaging method that captures both electrophysiological and hemodynamic information to explore the spatiotemporal characteristics of brain activity. Because of the significance of visually evoked functional activity in clinical applications, numerous studies have explored the amplitude of the visual evoked potential (VEP) to clarify its relationship with the hemodynamic response. However, relatively few studies have investigated the influence of latency, which has been frequently used to diagnose visual diseases, on the hemodynamic response. Moreover, because the latency and the amplitude of VEPs have different roles in coding visual information, investigating the relationship between latency and the hemodynamic response should be helpful. In this study, checkerboard reversal tasks with graded contrasts were used to evoke visual functional activity. Both EEG and fNIRS were employed to investigate the relationship between neuronal electrophysiological activities and the hemodynamic responses. The VEP amplitudes were linearly correlated with the hemodynamic response, but the VEP latency showed a negative linear correlation with the hemodynamic response.

  2. Cationic agent contrast-enhanced computed tomography imaging of cartilage correlates with the compressive modulus and coefficient of friction.

    Science.gov (United States)

    Lakin, B A; Grasso, D J; Shah, S S; Stewart, R C; Bansal, P N; Freedman, J D; Grinstaff, M W; Snyder, B D

    2013-01-01

    The aim of this study is to evaluate whether contrast-enhanced computed tomography (CECT) attenuation, using a cationic contrast agent (CA4+), correlates with the equilibrium compressive modulus (E) and coefficient of friction (μ) of ex vivo bovine articular cartilage. Correlations between CECT attenuation and E (Group 1, n = 12) and μ (Group 2, n = 10) were determined using 7 mm diameter bovine osteochondral plugs from the stifle joints of six freshly slaughtered, skeletally mature cows. The equilibrium compressive modulus was measured using a four-step, unconfined, compressive stress-relaxation test, and the coefficients of friction were determined from a torsional friction test. Following mechanical testing, samples were immersed in CA4+, imaged using μCT, rinsed, and analyzed for glycosaminoglycan (GAG) content using the 1,9-dimethylmethylene blue (DMMB) assay. The CECT attenuation was positively correlated with the GAG content of bovine cartilage (R(2) = 0.87, P coefficients of friction: CECT vs μ(static) (R(2) = 0.71, P = 0.002), CECT vs μ(static_equilibrium) (R(2) = 0.79, P coefficient of friction. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  3. The transesophageal echocardiography simulator based on computed tomography images.

    Science.gov (United States)

    Piórkowski, Adam; Kempny, Aleksander

    2013-02-01

    Simulators are a new tool in education in many fields, including medicine, where they greatly improve familiarity with medical procedures, reduce costs, and, importantly, cause no harm to patients. This is so in the case of transesophageal echocardiography (TEE), in which the use of a simulator facilitates spatial orientation and helps in case studies. The aim of the project described in this paper is to simulate an examination by TEE. This research makes use of available computed tomography data to simulate the corresponding echocardiographic view. This paper describes the essential characteristics that distinguish these two modalities and the key principles of the wave phenomena that should be considered in the simulation process, taking into account the conditions specific to the echocardiography. The construction of the CT2TEE (Web-based TEE simulator) is also presented. The considerations include ray-tracing and ray-casting techniques in the context of ultrasound beam and artifact simulation. An important aspect of the interaction with the user is raised.

  4. Undetected rheumatic heart disease revealed using portable echocardiography in a population of school students in Tairawhiti, New Zealand.

    Science.gov (United States)

    Cramp, Geoffrey; Stonehouse, Mary; Webb, Rachel; Webb, Rachel; Chaffey-Aupouri, Gina; Wilson, Nigel

    2012-10-12

    The aim of this programme was to find undetected rheumatic heart disease (RHD) in students from selected schools in the Tairawhiti region (eastern part of the North Island) of New Zealand. Portable echocardiography was used to scan students in 5 urban and rural schools in Tairawhiti where the population is predominantly Maori. The age range of students in the urban schools was 10-13 years and in the rural schools 5-17 years. Those with abnormal echocardiograms were referred for a paediatric consultation, with hospital-based echocardiography if required for the clarification of diagnoses and further management. A total of 685 students, representing over 95% of the schools' students, consented to having echocardiographic scanning. After repeat hospital based echocardiography for 11 students, a total of 52 scans were regarded as abnormal. In this population definite (n=4) or probable (n=7) RHD was found in 11 students a prevalence of 1.61% (95%CIs 0.80-2.85). Possible RHD was found in 19 students. Previously undetected confirmed (n=1) or probable (n=7) RHD was found in 8 students a prevalence of 1.17% (95%CIs 0.51-2.29). Congenital heart defects (CHD) were found in 22 students a prevalence of 3.21% (95%CIs 2.02-4.83). Echocardiography was a popular modality and detected a significant burden of previously unknown RHD in this young Maori population who are now receiving penicillin. However, echocardiography detected a greater prevalence of possible RHD for which optimum management is at present uncertain. Echocardiography also detected students with a range of severity of CHD. Screening with echocardiography for RHD would involve a significant use of public health, paediatric and cardiac resources with 7.6% of students and their families requiring clinical consultations and ongoing management of the abnormal echocardiographic results.

  5. Echocardiography-guided Radiofrequency Catheter Ablation of Atrioventricular Node and VVI Pacemaker Implantation

    Directory of Open Access Journals (Sweden)

    T Guo

    2014-05-01

    Full Text Available Objective: This study is to evaluate the feasibility and safety of intracardiac radiofrequency catheter ablation (RFCA of the atrioventricular node (AVN and pacemaker implantation using transthoracic echocardiography. Methods: Eleven patients – six males and five females (mean age 66 years – with persistent or permanent atrial fibrillation/atrial flutter received RFCA of AVN and VVI pacemaker implantation (paces and senses the ventricle and is inhibited if it senses ventricular activity. Under transthoracic echocardiography, the electrode catheters were positioned intracardiac, and target ablation was performed, with the permanent pacemaking catheter in the left subclavian vein and the ablation catheter in the right femoral vein. The multi-view imaging and dynamic observation applied during the stable AV dissociation were successful. Results: Atrioventricular node ablation and permanent pacemaker implantation in 11 patients were completed successfully without X-ray exposure. The operation success rate was 100%. All patients recovered well within the follow-up period. Conclusions: Radiofrequency catheter ablation of AVN and VVI pacemaker implantation under transthoracic echocardiography guidance is a safe, easy and feasible approach. This procedure could be an important supplemental measure to catheter ablation of arrhythmia under routine X-ray fluoroscopy.

  6. Reliability of quantitative echocardiography in adult sheep and goats

    Directory of Open Access Journals (Sweden)

    Hallowell Gayle D

    2012-09-01

    Full Text Available Abstract Background Echocardiography is a non-invasive method for assessment of the ovine and caprine heart. Complete reference ranges for cardiac dimensions and time indices for both species are not currently available and reliability of these measurements has not been evaluated. The objectives for this study are to report reliability, normal cardiac dimensions and time indices in a large group of adult sheep and goats. Fifty-one adult sheep and forty adult goats were recruited. Full echocardiographic examinations were performed in the standing unsedated animal. All animals underwent echocardiography four times in a 72-hour period. Echocardiography was performed three times by one author and once by another. Images were stored and measured offline. Technique and measurement repeatability and reproducibility and any differences due to animal or day were evaluated. Reference ranges (mean ± 2 standard deviations were calculated for both species. Results Majority of the images obtained were of good to excellent quality. Image acquisition was straightforward with 5.4% of animals demonstrating a small scanning window. Reliability was excellent for majority of dimensions and time indices. There was less variation in repeatability when compared with reproducibility and differences were greater for technique than for measurements. Dimensions that were less reliable included those for right ventricular diameter and left ventricular free wall. There were many differences in cardiac dimensions between sheep and goats. Conclusions This study has demonstrated that specific reference ranges are required for these two species. Repeatability and reproducibility were excellent for the majority of cardiac dimensions and time indices suggesting that this technique is reliable and valuable for examination of clinical cases over time and for longitudinal research studies.

  7. Automatic computation of 2D cardiac measurements from B-mode echocardiography

    Science.gov (United States)

    Park, JinHyeong; Feng, Shaolei; Zhou, S. Kevin

    2012-03-01

    We propose a robust and fully automatic algorithm which computes the 2D echocardiography measurements recommended by America Society of Echocardiography. The algorithm employs knowledge-based imaging technologies which can learn the expert's knowledge from the training images and expert's annotation. Based on the models constructed from the learning stage, the algorithm searches initial location of the landmark points for the measurements by utilizing heart structure of left ventricle including mitral valve aortic valve. It employs the pseudo anatomic M-mode image generated by accumulating the line images in 2D parasternal long axis view along the time to refine the measurement landmark points. The experiment results with large volume of data show that the algorithm runs fast and is robust comparable to expert.

  8. Role of Echocardiography in the Management and Prognosis of Atrial Fibrillation

    Science.gov (United States)

    Silverman, David I; Ayirala, Srilatha R; Manning, Warren J

    2012-01-01

    Echocardiography plays a longstanding and vital role in the management of atrial fibrillation (AF). Advances in 2D imaging, Doppler echocardiography and strain imaging have all contributed to major progress in AF treatment. Echocardiographically measured left atrial (LA) volume is a powerful predictor of maintenance of sinus rhythm following cardioversion as well as risk of thrombus formation and thromboembolism. Doppler derived parameters of atrial mechanical function including atrial ejection force provide related prognostic information. Transesophageal echocardiocardiograpy (TEE) guided cardioversion of AF allows for rapid conversion to sinus rhythm without prolonged oral anticoagulation, and TEE serves as a useful tool during catheter ablation of AF and atrial flutter. Newer measures derived from speckle tracking offer great promise in further improving the care of patients with AF. PMID:28496715

  9. Pacing stress echocardiography

    Directory of Open Access Journals (Sweden)

    Agrusta Marco

    2005-12-01

    Full Text Available Abstract Background High-rate pacing is a valid stress test to be used in conjunction with echocardiography; it is independent of physical exercise and does not require drug administration. There are two main applications of pacing stress in the echo lab: the noninvasive detection of coronary artery disease through induction of a regional transient dysfunction; and the assessment of contractile reserve through peak systolic pressure/ end-systolic volume relationship at increasing heart rates to assess global left ventricular contractility. Methods The pathophysiologic rationale of pacing stress for noninvasive detection of coronary artery disease is obvious, with the stress determined by a controlled increase in heart rate, which is a major determinant of myocardial oxygen demand, and thereby tachycardia may exceed a fixed coronary flow reserve in the presence of hemodynamically significant coronary artery disease. The use of pacing stress echo to assess left ventricular contractile reserve is less established, but promising. Positive inotropic interventions are mirrored by smaller end-systolic volumes and higher end-systolic pressures. An increased heart rate progressively increases the force of ventricular contraction (Bowditch treppe or staircase phenomenon. To build the force-frequency relationship, the force is determined at different heart rate steps as the ratio of the systolic pressure (cuff sphygmomanometer/end-systolic volume index (biplane Simpson rule. The heart rate is determined from ECG. Conclusion Two-dimensional echocardiography during pacing is a useful tool in the detection of coronary artery disease. Because of its safety and ease of repeatability noninvasive pacing stress echo can be the first-line stress test in patients with permanent pacemaker. The force-frequency can be defined as up- sloping (normal when the peak stress pacing systolic pressure/end-systolic volume index is higher than baseline and intermediate stress

  10. Correlating intravenous radiographic contrast media reactions with the allergic profile

    International Nuclear Information System (INIS)

    Chua-Lim, A.; Enright, T.; Duda, E.; Lim, D.T.

    1987-01-01

    To determine the relevance of allergy as a predisposing factor in reactions to radiographic contrast media, the authors investigated the incidence of allergy among 100 randomly selected patients undergoing intravenous excretory urography and CT. The study population consisted of 50 reactors and 50 nonreactos to radiographic contrast media. All 100 subjects completed an allergy history, percutaneous allergy tests, and an in vitro specific IgE assay to common allergens. Thirty-four of 50 reactors had a positive allergy history, in contrast to 15 of 50 nonreactors (P < .001). Twenty-seven reactors had positive skin tests, in contrast to 12 of 50 nonreactors (P < .005). In vitro IgE assay results are pending. The results indicate that patients with positive histories or positive skin tests or both are at an increased risk for reactions to radiographic contrast media

  11. Prognostic value of real-time three-dimensional echocardiography compared to two-dimensional echocardiography in patients with systolic heart failure.

    Science.gov (United States)

    Mancuso, Frederico J N; Moises, Valdir A; Almeida, Dirceu R; Poyares, Dalva; Storti, Luciana J; Brito, Flavio S; Tufik, Sergio; de Paola, Angelo A V; Carvalho, Antonio C C; Campos, Orlando

    2018-04-01

    Heart failure (HF) is associated with morbidity and mortality. Real-time three-dimensional echocardiography (RT3DE) may offer additional prognostic data in patients with HF. The study aimed to evaluate the prognostic value of real-time three-dimensional echocardiography (RT3DE). This is a prospective study that included 89 patients with HF and left ventricular ejection fraction (LVEF) < 0.50 who were followed for 48 months. Left atrium and ventricular volumes and functions were evaluated by RT3DE. TDI and two-dimensional echocardiography parameters were also obtained. The endpoint was a composite of death, heart transplantation and hospitalization for acute decompensated HF. The mean age was 55 ± 11 years, and the LVEF was 0.32 ± 0.10. The composite endpoint occurred in 49 patients (18 deaths, 30 hospitalizations, one heart transplant). Patients with outcomes had greater left atrial volume (40 ± 16 vs. 32 ± 12 mL/m 2 ; p < 0.01) and right ventricle diameter (41 ± 9 vs. 37 ± 8 mm, p = 0.01), worse total emptying fraction of the left atrium (36 ± 13% vs. 41 ± 11%; p = 0.03), LVEF (0.30 ± 0.09 vs. 0.34 ± 0.11; p = 0.02), right ventricle fractional area change (34.8 ± 12.1% vs. 39.2 ± 11.3%; p = 0.04), and greater E/e' ratio (19 ± 9 vs. 16 ± 8; p = 0.04) and systolic pulmonary artery pressure (SPAP) (50 ± 15 vs. 36 ± 11 mmHg; p < 0.01). In multivariate analysis, LVEF (OR 4.6; CI 95% 1.2-17.6; p < 0.01) and SPAP (OR 12.5; CI 95% 1.8-86.9; p < 0.01) were independent predictors of patient outcomes. LVEF and the SPAP were independent predictors of outcomes in patients with HF.

  12. Diagnostic value of exercise stress testing, dipyridamole stress-echocardiography and perfusion stress-scintigraphy for identification of coronary artery disease in women

    International Nuclear Information System (INIS)

    Debnath, S.; Tyrnovska-Kydreva, R.; Khalacheva, S.; Radoslavova, R.; Stoyanova, N.; Draganov, T.; Elenkova, A.; Garcheva, M.; Shejretova, E.

    1995-01-01

    To compare the value of exercise stress testing (EST), dipyridamole stress echocardiography and 99m Tc-methoxy-isobutyl-isonitrile (MIBI)-planer scintigraphy, 75 female patients with angina pectoris who underwent coronary angiography were studied. Significant (≥50% stenosis) coronary artery disease (CAD) was present in 38 of the patients. EST was performed in all of the patients but dipyridamole echocardiography and MIBI-planer scintigraphy - in 36 of them (22 with and 14 without CAD). Compared with dipyridamole echocardiography, EST and MIBI-planer scintigraphy had a significantly higher sensitivity (74% vs 45%, p<0.01 and 82% vs 45%, p<0.01, respectively). There was no significant difference in sensitivity between EST and MIBI-planer scintigraphy. Dipyridamole echocardiography and MIBI-planer scintigraphy showed a higher specificity than EST (93% vs 54%, p<0.01 and 93% vs 54%, p<0.01, respectively). Diagnostic accuracy of MIBI-planer scintigraphy was higher than that of dipyridamole echocardiography and EST (86% vs 64%, p<0.05 and 86 vs 64%, p<0.01, respectively). Thus, MIBI-planer scintigraphy appears to be superior to EST and dipyridamole echocardiography for the evaluation of CAD in symptomatic women. 20 refs., 2 tabs. (author)

  13. Can Stress Echocardiography Compete with Perfusion Scintigraphy in the Detection of Coronary Artery Disease and Cardiac Risk Assessment?

    NARCIS (Netherlands)

    M.L. Geleijnse (Marcel); A. Elhendy (Abdou)

    2000-01-01

    textabstractAims: The aim of this review was to define the place of stress echocardiography in the context of perfusion scintigraphy for the detection of coronary artery disease (CAD) and the assessment of cardiac risk. Stress echocardiography has the benefits of widespread availability, relatively

  14. Optimization of special heart disease diagnosis by combined computerized tomography, echocardiography and intracardiac scintiscanning

    International Nuclear Information System (INIS)

    Freitag, J.; Schmidt, H.; Otto, H.J.; Punrich, R.; Gunkel, H.; Mann, D.; Freitag, G.; Waigand, J.; Eger, H.; Zentralklinik fuer Herz- u. Lungenkrankheiten, Bad Berka; Akademie der Wissenschaften der DDR, Berlin-Buch. Zentralinstitut fuer Herz-Kreislaufforschung)

    1986-01-01

    Cardiac computer tomography, echocardiography and radionuclide heart diagnosis are growing more and more important in cardiologic diagnostics. The value of the procedures was tested in 74 patients by combined application. Concordant morphologic findings could be obtained with echocardiography and cardiac computer tomography in the cases of chronic ischemic heart disease, cardiomyopathy and valvular heart diseases. Localized kinetic disturbances could be registered echocardiographically and by scintiscanning. The passableness of an aortocoronary bypass can be controlled first of all non-invasively by cardiac computer tomography. (author)

  15. Dynamic contrast-enhanced MR of the prostatic cancer and benign prostatic hyperplasia: correlation with angiogenesis

    International Nuclear Information System (INIS)

    Ni Xinchu; Shen Junkang; Lu Zhian; Zhou Lijuan; Yang Xiaochun; Wang Guanzhong; Zhang Caiyuan; Wang Shuizhen; Qian Minghui; Chan Yuxi; Qian Nong; Xiang Jianpo; Pan Changjie; Rong Weiliang; Chen Jianguo

    2005-01-01

    Objective: To evaluate the role of dynamic contrast-enhanced magnetic resonance imaging (MRI) in the diagnose of prostatic cancer and benign prostatic hyperplasia (BPH), and to determine the correlation between dynamic MRI findings with angiogenesis. Methods: Thirty-two cases of prostatic cancer and 40 cases of BPH underwent dynamic contrast-enhanced MRI. All the patients in this study were diagnosed by histopathology. The results of dynamic contrast-enhanced MRI were evaluated by early-phase enhancement parameters and time-signal intensity curves (SI-T curves), and the curves were classified according to their shapes as type I, which had steady enhancement; type II, plateau of signal intensity; and type III, washout of signal intensity. The pathologic specimens of region of interest (ROI ) were obtained, and HE staining, immunohistochemical vascular endothelial growth factor (VEGF), and microvessel density (MVD) measurements were performed. The relationships among dynamic contrast-enhanced MRI features, VEGF, and MVD expression were analyzed. Results: In the early-phase enhancement parameters of dynamic contrast-enhanced MRI, onset time, maximum signal intensity, and early-phase enhancement rate differed between prostatic cancer and BPH (P<0.01, 0.05, 0.01), but there were some overlaps between them. The intermediate and late post-contrast periods were characterized with the lesion SI-T curves. The SI-T curve of prostatic cancer was mainly type III (21 cases). Type II could be seen in both prostatic cancer (8 cases) and BPH (19 cases). Type I most appeared in BPH (18 cases). The distributions proved to have significant difference (P<0.001). The mean VEGF and MVD level of 32 prostatic cancer patients were significantly higher than those of 40 BPH patients (P<0.001). MVD level of prostatic cancer and BPH showed an association with VEGF level (P<0.01). The maximum signal intensity and early-phase enhancement rate in both prostatic cancer and BPH showed an association

  16. Agreement of left ventricular ejection fraction and volumes between adenosine stress TL-201 gated SPECT and echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Pai, M. S. [College of Medicine, Univ. of Ewha, Seoul (Korea, Republic of); Moon, D. H.; Kim, H. M.; Yang, Y. J.; Kang, D. H. [Asan Medical Center, Seoul (Korea, Republic of)

    2003-07-01

    Electrocardiogram-gated TI-201 SPECT measurements of left ventricular ejection fraction (EF), end-diastolic volume (EDV), and end-systolic volume (ESV) have shown high correlation with conventional methods. However, how much these parameters measured by TI-201 gated SPECT differ from those by echocardiography has not been assessed. Adenosine stress (Ad-G) and redistribution TI-201 gated SPECT (Re-G) and resting echocardiography were conducted in 337 patients (184 male, 153 female). EDV, ESV and LVEF measured by QGS software were compared with the results by echocardiography. Patients with arrhythmia (atrial fibrillation or frequent premature contractions) or evidence of fixed or reversible perfusion defects on TI-201 SPECT were excluded. EF, EDV and ESV measured by Ad-G (63.3{+-}9.8,73.8{+-}30.2,29.1{+-}20.1) and Re-G (65.2{+-}11.6,69.1{+-}30.1,26.5{+-}20.3) correlated well with those by Echo (61.4{+-}7.9,78.3{+-}2.7, 30.7{+-} 17.5 ; r of Ad-G=0.547, 0.850, 0.827, p<0.001 ; r of Re-G=0.585, 0.838, 0.819, p<0.001). However the difference (mean, SD, SEE of Echo - gated SPECT) was statistically significant (EF: Ad-G=1.71, 8.92, 0.48, Re-G=3.59, 10.39, 0.56, p<0.001 ; EDV: Ad-G=4.75, 16.21, 0.88, Re-G=9.53, 16.77, 0.91, p<0.001 ; ESV: Ad-G=1.75, 11.35, 0.61, p<0.05, Re-G=4.29, 11.7, 0.63, p<0.001). Bland-Altman plots showed that the difference of EDV and ESV did not vary in any systematic way over the range of measurement, whereas the difference of EF increased with increasing average EF by Echo and gated-SPECT. The difference of EF, EDV, and ESV between Ad-G and Echo was significantly smaller than those between Re-G and Echo (p<0.001). Gated TI-201 SPECT underestimates EDV and ESV over a wide range of volume. As a result, EF by gated TI-201 SPECT is overestimated especially in patients with small LV volume. Ad-G is preferable to Re-G in assessing left ventricular ejection fraction and volume in place of Echo because of smaller bias.

  17. Fine-grained information extraction from German transthoracic echocardiography reports.

    Science.gov (United States)

    Toepfer, Martin; Corovic, Hamo; Fette, Georg; Klügl, Peter; Störk, Stefan; Puppe, Frank

    2015-11-12

    Information extraction techniques that get structured representations out of unstructured data make a large amount of clinically relevant information about patients accessible for semantic applications. These methods typically rely on standardized terminologies that guide this process. Many languages and clinical domains, however, lack appropriate resources and tools, as well as evaluations of their applications, especially if detailed conceptualizations of the domain are required. For instance, German transthoracic echocardiography reports have not been targeted sufficiently before, despite of their importance for clinical trials. This work therefore aimed at development and evaluation of an information extraction component with a fine-grained terminology that enables to recognize almost all relevant information stated in German transthoracic echocardiography reports at the University Hospital of Würzburg. A domain expert validated and iteratively refined an automatically inferred base terminology. The terminology was used by an ontology-driven information extraction system that outputs attribute value pairs. The final component has been mapped to the central elements of a standardized terminology, and it has been evaluated according to documents with different layouts. The final system achieved state-of-the-art precision (micro average.996) and recall (micro average.961) on 100 test documents that represent more than 90 % of all reports. In particular, principal aspects as defined in a standardized external terminology were recognized with f 1=.989 (micro average) and f 1=.963 (macro average). As a result of keyword matching and restraint concept extraction, the system obtained high precision also on unstructured or exceptionally short documents, and documents with uncommon layout. The developed terminology and the proposed information extraction system allow to extract fine-grained information from German semi-structured transthoracic echocardiography reports

  18. Feasibility, safety and tolerability of accelerated dobutamine stress echocardiography

    Directory of Open Access Journals (Sweden)

    Pavaci Herribert

    2007-11-01

    Full Text Available Abstract A continuous infusion of a single high dose of dobutamine has been, recently, suggested as a simple and effective protocol of stress echocardiography. The present study assesses the feasibility, safety, and tolerability of an accelerated dobutamine stress protocol performed in patients with suspected or known coronary artery disease. Two hundred sixty five consecutive patients underwent accelerated dobutamine stress echocardiography: the dobutamine was administered at a constant dose of 50 μg/kg/min for up to 10 minutes. The mean weight-adjusted cumulative dose of dobutamine used was 330 ± 105.24 μg/kg. Total duration of dobutamine infusion was 6.6 ± 2.1 min. Heart rate rose from 69.9 ± 12.1 to 123.1 ± 22.1 beats/min at peak with a concomitant change in systolic blood pressure (127.6 ± 18.1 vs. 167.6 ± 45.0 mmHg. Dobutamine administration produced a rapid increase in heart rate (9.4 ± 5.9 beats/min2. The side effects were similar to those described with the standard protocol; the most common were frequent premature ventricular complexes (21.5%, frequent premature atrial complexes (1.5% and non sustained ventricular tachycardia (1.5%; among non cardiac symptoms the most frequent were nausea (3.4%, headache (1.1% and symptomatic hypotension (1.1%. No major side effects were observed during the test. Our data demonstrate that a continous infusion of a single high dose of dobutamine is a safe and well tolerated method of performing stress echocardiography in patients with suspected or known coronary artery disease. This new protocol requires the administration of lower cumulative dobutamine dose than standard protocol and results in a significant reduction in test time.

  19. Improved Imaging in Cardiac Patients: echocardiography and CT-coronary angiography

    NARCIS (Netherlands)

    T.W. Galema (Tjebbe)

    2010-01-01

    textabstractDiff erent non-invasive imaging modalities are used for to assess cardiac anatomy and function. Echocardiography and MRI allow assessment of cardiac structures and function of the cardiac chambers and valves as well as perfusion of the left ventricular wall while CT-angiography in

  20. Are microbubbles free flowing tracers through the Myocardium? Comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging.

    Science.gov (United States)

    Tiemann, K; Schlosser, T; Pohl, C; Bimmel, D; Wietasch, G; Hoeft, A; Likungu, J; Vahlhaus, C; Kuntz, S; Nanda, N C; Becher, H; Lüderitz, B

    2000-01-01

    Harmonic power Doppler imaging (H-PDI) has been introduced into the field of contrast echocardiography as a contrast-specific imaging modality. However, there has been considerable skepticism as to whether H-PDI would be quantifiable, because it depends on the destruction of microbubbles and has more complex signal processing than gray scale imaging. The aim of the present study was to evaluate the relationship between the concentration of microbubbles and the resulting H-PDI signals even under conditions where bubble destruction is most likely. Furthermore, we evaluated whether microbubbles of Levovist freely pass the microcirculation, which is a prerequisite for the assessment of myocardial blood flow. A strong positive correlation was found between the H-PDI signals and the amount of microbubbles up to the onset of acoustic shadowing (r = 0. 968, Pgreen (ICG) in both a flow phantom and a working heart setup. The mean transit times (MTTs) through the myocardium of both agents were compared after a bolus injection into the left coronary artery. A close correlation was observed between 1/MTT and flow in both setups (r>0.98, Pgreen. We conclude that microbubbles fulfill the prerequisites of free flowing tracers through the myocardium. Furthermore, H-PDI technology allows a reliable assessment of time-concentration curves of air-filled microbubbles up to the onset of acoustic shadowing.

  1. Clinical assessment of transthoracic echocardiography skills: a generalizability study

    DEFF Research Database (Denmark)

    Nielsen, Dorte Guldbrand; O'Neill, Lotte; Jensen, Signe

    2015-01-01

    Context: Transthoracic echocardiography (TTE) is a widely used cardiac imaging technique that all cardiologists should be able to perform competently. Traditionally, TTE competence has been assessed by unstructured observation or in test situations separated from daily clinical practice. An objec......Context: Transthoracic echocardiography (TTE) is a widely used cardiac imaging technique that all cardiologists should be able to perform competently. Traditionally, TTE competence has been assessed by unstructured observation or in test situations separated from daily clinical practice....... An objective assessment instrument for TTE technical proficiency including a global rating score and a checklist score has previously been shown reliability and validity in a standardised setting. Objectives: As clinical test situations typically have several sources of error giving rise to variance in scores......, a more thorough examination of the generalizability of the test scores is needed. Methods Nine physicians performed a TTE scan on the same three patients. Then, two raters rated all 27 TTE scans using the TTE technical assessment in a fully crossed generalizability study. Estimated variance components...

  2. Early detection of myocardial dysfunction using two-dimensional speckle tracking echocardiography in a young cat with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Ryohei Suzuki

    2018-02-01

    Full Text Available Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI. The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed abnormalities in myocardial deformations, including decreased early-to-late diastolic strain rate ratios in longitudinal, radial and circumferential directions, and deteriorated segmental systolic longitudinal strain. At the follow-up examinations, the cat exhibited echocardiographic left ventricular hypertrophy and was diagnosed with hypertrophic cardiomyopathy using conventional echocardiography. Relevance and novel information This is the first report on the use of two-dimensional speckle tracking echocardiography for the early detection of myocardial dysfunction in a cat with hypertrophic cardiomyopathy; the myocardial dysfunction was detected before the development of hypertrophy. The findings from this case suggest that two-dimensional speckle tracking echocardiography can be useful for myocardial assessment when conventional echocardiographic and Doppler findings are ambiguous.

  3. Successful thrombectomy of a stuck mechanical prosthetic mitral valve guided by perioperative transesophageal echocardiography and cinefluoroscopy

    Directory of Open Access Journals (Sweden)

    Paulo César Gobert Damasceno Campos

    2009-03-01

    Full Text Available We describe the case of a 53-year-old man with past history of rheumatic valvular disease who developed acute decompensated heart failure due to thrombosis of his mechanical mitral valve prosthesis. The diagnosis was established after a combined and complementary approach of echocardiography and cinefluoroscopy. Because of the severe heart failure at presentation, the patient was taken to surgery. The intraoperative transesophageal echocardiography was critical to guide a successful thrombectomy procedure. Postoperative pathological findings revealed the presence of thrombus and fibrotic tissue (pannus in the surgical specimens removed from the valve. The success of this case and the treatment choice are supported by the most recent literature data on prosthetic valve thrombosis. We highlight the use of three diagnostic approaches in our patient: echocardiography, cinefluoroscopy and pathology.

  4. Three-dimensional echocardiography: assessment of inter- and intra-operator variability and accuracy in the measurement of left ventricular cavity volume and myocardial mass

    International Nuclear Information System (INIS)

    Nadkarni, S.K.; Drangova, M.; Boughner, D.R.; Fenster, A.; Department of Medical Biophysics, Medical Sciences Building, University of Western Ontario, London, Ontario N6A 5C1

    2000-01-01

    Accurate left ventricular (LV) volume and mass estimation is a strong predictor of cardiovascular morbidity and mortality. We propose that our technique of 3D echocardiography provides an accurate quantification of LV volume and mass by the reconstruction of 2D images into 3D volumes, thus avoiding the need for geometric assumptions. We compared the accuracy and variability in LV volume and mass measurement using 3D echocardiography with 2D echocardiography, using in vitro studies. Six operators measured the LV volume and mass of seven porcine hearts, using both 3D and 2D techniques. Regression analysis was used to test the accuracy of results and an ANOVA test was used to compute variability in measurement. LV volume measurement accuracy was 9.8% (3D) and 18.4% (2D); LV mass measurement accuracy was 5% (3D) and 9.2% (2D). Variability in LV volume quantification with 3D echocardiography was %SEM inter = 13.5%, %SEM intra = 11.4%, and for 2D echocardiography was %SEM inter = 21.5%, %SEM intra = 19.1%. We derived an equation to predict uncertainty in measurement of LV volume and mass using 3D echocardiography, the results of which agreed with our experimental results to within 13%. 3D echocardiography provided twice the accuracy for LV volume and mass measurement and half the variability for LV volume measurement as compared with 2D echocardiography. (author)

  5. An Echocardiography Training Program for Improving the Left Ventricular Function Interpretation in Emergency Department; a Brief Report

    Directory of Open Access Journals (Sweden)

    Mary S. Jacob

    2017-06-01

    Full Text Available Introduction: Focused training in transthoracic echocardiography enables emergency physicians (EPs to accurately estimate the left ventricular function. This study aimed to evaluate the efficacy of a brief training program utilizing standardized echocardiography video clips in this regard. Methods: A before and after design was used to determine the efficacy of a 1 hour echocardiography training program using PowerPoint presentation and standardized echocardiography video clips illustrating normal and abnormal left ventricular ejection fraction (LVEF as well as video clips emphasizing the measurement of mitral valve E-point septal separation (EPSS. Pre- and post-test evaluation used unique video clips and asked trainees to estimate LVEF and EPSS based on the viewed video clips. Results: 21 EPs with no prior experience with the echocardiographic technical methods completed this study. The EPs had very limited prior echocardiographic training. The mean score on the categorization of LVEF estimation improved from 4.9 (95% CI: 4.1-5.6 to 7.6 (95%CI: 7-8.3 out of a possible 10 score (p<0.0001. Categorization of EPSS improved from 4.1 (95% CI: 3.1-5.1 to 8.1 (95% CI: 7.6- 8.7 after education (p<0.0001. Conclusions: The results of this study demonstrate a statistically significant improvement of EPs’ ability to categorize left ventricular function as normal or depressed, after a short lecture utilizing a commercially available DVD of standardized echocardiography clips.

  6. Association between aortic valve calcification measured on non-contrast computed tomography and aortic valve stenosis in the general population

    DEFF Research Database (Denmark)

    Paulsen, Niels Herluf; Bønløkke Carlsen, Bjarke; Dahl, Jordi Sanchez

    2016-01-01

    BACKGROUND: Aortic valve calcification (AVC) measured on non-contrast computed tomography (CT) has shown correlation to severity of aortic valve stenosis (AS) and mortality in patients with known AS. The aim of this study was to determine the association of CT verified AVC and subclinical...... AS in a general population undergoing CT. METHODS: CT scans from 566 randomly selected male participants (age 65-74) in the Danish cardiovascular screening study (DANCAVAS) were analyzed for AVC. All participants with a moderately or severely increased AVC score (≥300 arbitrary units (AU)) and a matched control...... ICD leads 16 individuals were excluded from the AVC scoring. Moderate or severe increased AVC was observed in 10.7% (95% CI: 8.4-13.7). Echocardiography was performed in 101 individuals; 32.7% (95% CI: 21.8 to 46.0) with moderate or high AVC score had moderate or severe AS, while none with no or low...

  7. Echocardiography in Arterial Hypertension.

    Science.gov (United States)

    de Simone, Giovanni; Mancusi, Costantino; Esposito, Roberta; De Luca, Nicola; Galderisi, Maurizio

    2018-05-02

    Hypertension is a condition characterized by pressure and/or volume overloads and echocardiography is helpful and feasible to understand hemodynamic mechanisms. Echocardiographic information is sometimes critical and susceptible of modifying decision making. In this review, we provide detailed descriptions of the parameters that can be derived from a standard transthoracic echocardiogram, including some more recent techniques. We will also explain how each parameter might have impact in the evaluation of the hypertensive patient and give indications on when to refer patients to echo-labs, which parameters are critical and which ones might be redundant, and how to use the information obtained in the report. Cardiac geometry, LV systolic and diastolic function, LV pump performance, output impedance and left atrial function are parameters that might be altered in arterial hypertension, but not necessarily doctors need the whole information for decision making. The critical measures are provided.

  8. Ekhokardiografi Endokardiosis Penyakit Katup Mitral Jantung Anjing (ECHOCARDIOGRAPHY OF ENDOCARDIOSIS MITRAL VALVE HEART DISEASE IN DOGS

    Directory of Open Access Journals (Sweden)

    Deni Noviana

    2013-08-01

    Full Text Available Endocardiosis is a disease commonly found in Pomeranian dog characterized by progressive myxomatousdegeneration of the atrio-ventricular valves especially in the mitral valve. The purpose of this study was todefine the diagnose and severeity of this disease on the Pomeranian by using brightness mode, motion mode,dan color flow Doppler echocardiography technique. Echocardiography was performed on 8 Pomeranianconsisting of 6 males and 2 females with age range of 2-14 years. Brightness mode echocardiography wasused to see the echotexture of endocardium, mitral valve, and the valve movement. The results showedendocardium thickening, along with chronic fibrosis and nodular thickening of the anterior and posteriormitral valve leaflet. Three out of seven cases showed prolapsed of the mitral valve. Motion modeechocardiography was performed in order to measure left ventricle internal dimension, myocardium thickness,fractional shortening, left atrial and aortic dimension. The results showed myocardium thickening, alongwith left atrial enlargement. Color flow Doppler echocardiography was used to confirm the mitral valveregurgitation. Three of seven cases showed the presence of regurgitation signed by turbulence color of theprolapsed mitral valve. Based on the degree of severity, scoring system used in this study, endocardiosis canbe divided into three types that are mild, moderate and severe.

  9. Comparison of exercise stress testing with dobutamine stress echocardiography and exercise technetium-99m isonitrile single photon emission computerized tomography for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Oguzhan, A.; Kisacik, H.L.; Ozdemir, K.

    1997-01-01

    To compare the value of exercise electrocardiography with dobutamine stress echocardiography and exercise technetium-99m isonitrile single-photon emission computed tomography for coronary artery disease, 70 patients with either suspected or proven coronary artery disease underwent dobutamine stress echocardiography, exercise technetium-99m isonitrile single-photon emission computed tomography (mibi-SPECT) and treadmill exercise electrocardiography (ECG). Dobutamine echocardiography and exercise mibi-SPECT revealed a higher overall sensitivity than exercise testing (90 vs 57%, p 0.05; 90 and 62% p<0.05, respectively) but the difference between dobutamine stress echocardiography and exercise mibi-SPECT was not statistically significant. Diagnostic accuracy of dobutamine stress echocardiography and exercise mibi-SPECT was higher than that of exercise testing (90 vs 59%, p<0.001; 89 vs 59%, p<0.001, respectively). Dobutamine stress echocardiography and exercise mibi-SPECT have superiority over exercise testing in the diagnosis of coronary artery disease and dobutamine stress echocardiography is an alternative for exercise mibi-SPECT. (author)

  10. Transesophageal echocardiography as an alternative for the assessment of the trauma and critical care patient.

    Science.gov (United States)

    Rose, David D

    2003-06-01

    Transesophageal echocardiography was first described and used to monitor cardiac function in 1976. Initially adopted by cardiac anesthesiologists and cardiologists, it has gained acceptance as an important diagnostic tool in the monitoring and assessment of cardiac status in the critically ill and trauma patient population. Comparative data suggest that transesophageal echocardiography provides rapid real-time noninvasive monitoring of the critically ill and avoids the morbidity and mortality that is associated with more invasive methods of patient monitoring. In addition, transesophageal echocardiography affords the practitioner reliable cardiac filling volumes based on direct left ventricular assessment compared to pressure data that are based on indirect right ventricular and pulmonary occlusive pressures. In a healthcare environment that seeks optimum patient assessment while requiring an approach that encourages cost-effective, noninvasive, and minimal patient risk, those nurse anesthetists who work in institutions that have transesophageal echocardiographic capabilities should learn this newer technology and begin to incorporate it into their practice.

  11. Correlation of contrast-detail analysis and clinical image quality assessment in chest radiography with a human cadaver study.

    Science.gov (United States)

    De Crop, An; Bacher, Klaus; Van Hoof, Tom; Smeets, Peter V; Smet, Barbara S; Vergauwen, Merel; Kiendys, Urszula; Duyck, Philippe; Verstraete, Koenraad; D'Herde, Katharina; Thierens, Hubert

    2012-01-01

    To determine the correlation between the clinical and physical image quality of chest images by using cadavers embalmed with the Thiel technique and a contrast-detail phantom. The use of human cadavers fulfilled the requirements of the institutional ethics committee. Clinical image quality was assessed by using three human cadavers embalmed with the Thiel technique, which results in excellent preservation of the flexibility and plasticity of organs and tissues. As a result, lungs can be inflated during image acquisition to simulate the pulmonary anatomy seen on a chest radiograph. Both contrast-detail phantom images and chest images of the Thiel-embalmed bodies were acquired with an amorphous silicon flat-panel detector. Tube voltage (70, 81, 90, 100, 113, 125 kVp), copper filtration (0.1, 0.2, 0.3 mm Cu), and exposure settings (200, 280, 400, 560, 800 speed class) were altered to simulate different quality levels. Four experienced radiologists assessed the image quality by using a visual grading analysis (VGA) technique based on European Quality Criteria for Chest Radiology. The phantom images were scored manually and automatically with use of dedicated software, both resulting in an inverse image quality figure (IQF). Spearman rank correlations between inverse IQFs and VGA scores were calculated. A statistically significant correlation (r = 0.80, P chest radiography. © RSNA, 2011.

  12. Automated Processing of Dynamic Contrast-Enhanced MRI: Correlation of Advanced Pharmacokinetic Metrics with Tumor Grade in Pediatric Brain Tumors.

    Science.gov (United States)

    Vajapeyam, S; Stamoulis, C; Ricci, K; Kieran, M; Poussaint, T Young

    2017-01-01

    Pharmacokinetic parameters from dynamic contrast-enhanced MR imaging have proved useful for differentiating brain tumor grades in adults. In this study, we retrospectively reviewed dynamic contrast-enhanced perfusion data from children with newly diagnosed brain tumors and analyzed the pharmacokinetic parameters correlating with tumor grade. Dynamic contrast-enhanced MR imaging data from 38 patients were analyzed by using commercially available software. Subjects were categorized into 2 groups based on pathologic analyses consisting of low-grade (World Health Organization I and II) and high-grade (World Health Organization III and IV) tumors. Pharmacokinetic parameters were compared between the 2 groups by using linear regression models. For parameters that were statistically distinct between the 2 groups, sensitivity and specificity were also estimated. Eighteen tumors were classified as low-grade, and 20, as high-grade. Transfer constant from the blood plasma into the extracellular extravascular space (K trans ), rate constant from extracellular extravascular space back into blood plasma (K ep ), and extracellular extravascular volume fraction (V e ) were all significantly correlated with tumor grade; high-grade tumors showed higher K trans , higher K ep , and lower V e . Although all 3 parameters had high specificity (range, 82%-100%), K ep had the highest specificity for both grades. Optimal sensitivity was achieved for V e , with a combined sensitivity of 76% (compared with 71% for K trans and K ep ). Pharmacokinetic parameters derived from dynamic contrast-enhanced MR imaging can effectively discriminate low- and high-grade pediatric brain tumors. © 2017 by American Journal of Neuroradiology.

  13. Three-dimensional Speckle Tracking Echocardiography in Light Chain Cardiac Amyloidosis: Examination of Left and Right Ventricular Myocardial Mechanics Parameters.

    Science.gov (United States)

    Urbano-Moral, Jose Angel; Gangadharamurthy, Dakshin; Comenzo, Raymond L; Pandian, Natesa G; Patel, Ayan R

    2015-08-01

    The study of myocardial mechanics has a potential role in the detection of cardiac involvement in patients with amyloidosis. This study aimed to characterize 3-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics in light chain amyloidosis and examine their relationship with brain natriuretic peptide. In patients with light chain amyloidosis, left ventricular longitudinal and circumferential strain (n=40), and right ventricular longitudinal strain and radial displacement (n=26) were obtained by 3-dimensional-speckle tracking echocardiography. Brain natriuretic peptide levels were determined. All myocardial mechanics measurements showed differences when compared by brain natriuretic peptide level tertiles. Left and right ventricular longitudinal strain were highly correlated (r=0.95, P<.001). Left ventricular longitudinal and circumferential strain were reduced in patients with cardiac involvement (-9±4 vs -16±2; P<.001, and -24±6 vs -29±4; P=.01, respectively), with the most prominent impairment at the basal segments. Right ventricular longitudinal strain and radial displacement were diminished in patients with cardiac involvement (-9±3 vs -17±3; P<.001, and 2.7±0.8 vs 3.8±0.3; P=.002). On multivariate analysis, left ventricular longitudinal strain was associated with the presence of cardiac involvement (odds ratio = 1.6; 95% confidence interval, 1.04 to 2.37; P=.03) independent of the presence of brain natriuretic peptide and troponin I criteria for cardiac amyloidosis. Three-dimensional-speckle tracking echocardiography-derived left and right ventricular myocardial mechanics are increasingly altered as brain natriuretic peptide increases in light chain amyloidosis. There appears to be a strong association between left ventricular longitudinal strain and cardiac involvement, beyond biomarkers such as brain natriuretic peptide and troponin I. Copyright © 2015 Sociedad Española de Cardiología. Published by

  14. CHANGE DETECTION VIA SELECTIVE GUIDED CONTRASTING FILTERS

    Directory of Open Access Journals (Sweden)

    Y. V. Vizilter

    2017-05-01

    Full Text Available Change detection scheme based on guided contrasting was previously proposed. Guided contrasting filter takes two images (test and sample as input and forms the output as filtered version of test image. Such filter preserves the similar details and smooths the non-similar details of test image with respect to sample image. Due to this the difference between test image and its filtered version (difference map could be a basis for robust change detection. Guided contrasting is performed in two steps: at the first step some smoothing operator (SO is applied for elimination of test image details; at the second step all matched details are restored with local contrast proportional to the value of some local similarity coefficient (LSC. The guided contrasting filter was proposed based on local average smoothing as SO and local linear correlation as LSC. In this paper we propose and implement new set of selective guided contrasting filters based on different combinations of various SO and thresholded LSC. Linear average and Gaussian smoothing, nonlinear median filtering, morphological opening and closing are considered as SO. Local linear correlation coefficient, morphological correlation coefficient (MCC, mutual information, mean square MCC and geometrical correlation coefficients are applied as LSC. Thresholding of LSC allows operating with non-normalized LSC and enhancing the selective properties of guided contrasting filters: details are either totally recovered or not recovered at all after the smoothing. These different guided contrasting filters are tested as a part of previously proposed change detection pipeline, which contains following stages: guided contrasting filtering on image pyramid, calculation of difference map, binarization, extraction of change proposals and testing change proposals using local MCC. Experiments on real and simulated image bases demonstrate the applicability of all proposed selective guided contrasting filters. All

  15. Utility of physical examination and comparison to echocardiography for cardiac diagnosis

    Directory of Open Access Journals (Sweden)

    Ashish Patel

    2017-03-01

    Conclusion: Careful clinical auscultation using a stethoscope remains a valuable tool for cardiac diagnosis. Decision on initial diagnosis and management of valvular and congenital heart diseases should be based on clinical examination and integrating such information with echocardiography as required.

  16. Validation of noninvasive indices of global systolic function in patients with normal and abnormal loading conditions: a simultaneous echocardiography pressure-volume catheterization study.

    Science.gov (United States)

    Yotti, Raquel; Bermejo, Javier; Benito, Yolanda; Sanz-Ruiz, Ricardo; Ripoll, Cristina; Martínez-Legazpi, Pablo; del Villar, Candelas Pérez; Elízaga, Jaime; González-Mansilla, Ana; Barrio, Alicia; Bañares, Rafael; Fernández-Avilés, Francisco

    2014-01-01

    Noninvasive indices based on Doppler echocardiography are increasingly used in clinical cardiovascular research to evaluate left ventricular global systolic chamber function. Our objectives were to clinically validate ultrasound-based methods of global systolic chamber function to account for differences between patients in conditions of abnormal load, and to assess their sensitivity to load confounders. Twenty-seven patients (8 dilated cardiomyopathy, 10 normal ejection fraction, and 9 end-stage liver disease) underwent simultaneous echocardiography and left heart catheterization with pressure-conductance instrumentation. The reference index, maximal elastance (Emax), was calculated from pressure-volume loop data obtained during acute inferior vena cava occlusion. A wide range of values were observed for left ventricular systolic chamber function (Emax: 2.8±1.0 mm Hg/mL), preload, and afterload. Among the noninvasive indices tested, the peak ejection intraventricular pressure difference showed the best correlation with Emax (R=0.75). A significant but weaker correlation with Emax was observed for ejection fraction (R=0.41), midwall fractional shortening (R=0.51), global circumferential strain (R=-0.53), and strain rate (R=-0.46). Longitudinal strain and strain rate failed to correlate with Emax, as did noninvasive single-beat estimations of this index. Principal component and multiple regression analyses demonstrated that peak ejection intraventricular pressure difference was less sensitive to load, whereas ejection fraction and longitudinal strain and strain rate were heavily influenced by afterload. Current ultrasound methods have limited accuracy to characterize global left ventricular systolic chamber function in a given patient. The Doppler-derived peak ejection intraventricular pressure difference should be preferred for this purpose because it best correlates with the reference index and is more robust in conditions of abnormal load.

  17. Multiplanar transesophageal echocardiography for the evaluation and percutaneous management of ostium secundum atrial septal defects in the adult.

    Science.gov (United States)

    Sobrino, Ayax; Basmadjian, Arsène J; Ducharme, Anique; Ibrahim, Reda; Mercier, Lise-Andrée; Pelletier, Guy B; Marcotte, François; Garceau, Patrick; Burelle, Denis; O'Meara, Eileen; Dore, Annie

    2012-01-01

    The purpose of this paper is to review the usefulness of multiplanar transesophageal echocardiography before, during and after percutaneous transcatheter closure of secundum atrial septal defects. Transesophageal echocardiography imaging techniques,including their role in patient selection, procedural guidance and immediate assessment of technical success and complications are described and discussed in this review. Percutaneous transcatheter closure is indicated for ostium secundum atrial septal defects of less than 40 mm in maximal diameter. The defect must have a favorable anatomy, with adequate rims of at least 5 mm to anchor the prosthesis. Transesophageal echocardiography plays a critical role before the procedure in identifying potential candidates for percutaneous closure and to exclude those with unfavorable anatomy or associated lesions, which could not be addressed percutaneously. Transesophageal echocardiography is also important during the procedure to guide the deployment of the device. After device deployment, the echocardiographer must assess the device (integrity, position and stability), residual shunt, atrio-ventricular valve regurgitation, obstruction to systemic or venous return and pericardial effusion, in order to determine procedural success and diagnose immediate complications.

  18. Ruling out cardiac failure: Cost-benefit analysis of a sequential testing strategy with NT-proBNP before echocardiography

    Science.gov (United States)

    Ferrandis, Maria-José; Ryden, Ingvar; Lindahl, Tomas L.

    2013-01-01

    Objectives To estimate the possible economic benefit of a sequential testing strategy with NT-proBNP to reduce the number of echocardiographies. Methods Retrospective study in a third-party payer perspective. The costs were calculated from three Swedish counties: Blekinge, Östergötland, and Uppland. Two cut-off levels of NT-proBNP were used: 400 and 300 pg/mL. The cost-effectiveness of the testing strategy was estimated through the short-term cost avoidance and reduction in demand for echocardiographies. Results The estimated costs for NT-proBNP tests and echocardiographies per county were reduced by 33%–36% with the 400 pg/mL cut-off and by 28%–29% with the 300 pg/mL cut-off. This corresponded to a yearly cost reduction of approximately €2–5 million per million inhabitants in these counties. Conclusion The use of NT-proBNP as a screening test could substantially reduce the number of echocardiographies in the diagnostic work-up of patients with suspected cardiac failure, as well as the associated costs. PMID:23230860

  19. A study on maternal-fetal attachment in pregnant women undergoing fetal echocardiography

    Directory of Open Access Journals (Sweden)

    Concetta Polizzi

    2017-03-01

    Full Text Available Purpose: To investigate the possible effects of the fetal echocardiography experience on the prenatal attachment process. The predictive effect of specific women’s psychological variables will be explored as well.Design and methods: This between groups study involved 85 women with pregnancy at risk who underwent the fetal echocardiography, and 83 women who were about to undergo the morphological scan. The tools employed were: the Prenatal Attachment Inventory (P.A.I. to explore the maternal-fetal attachment; the Maternity Social Support Scale to investigate the woman perception of being socially supported during pregnancy; both the Big Five Questionnaire and the FACES III to explore the personality traits of pregnant women and their perception of their couple relationship functioning.Findings: The outcomes of ANOVA do not show statistically significant differences between the two groups of the mothers-to-be with regard to the scores of the P.A.I. (F = .017; p = .897; η2 = .000, while the regression analysis of the possible effect of the maternal psychological variables on the mother-fetus relationship shows a statistically significant result only with regard to the “social support” variable (r2 = .061; df = 80; p = .025.Conclusions: It would seem that the process of the prenatal attachment develops independently whether the woman has to undergo a first level screening or a second level examination such as the fetal echocardiography.

  20. Predicting and measuring fluid responsiveness with echocardiography

    Directory of Open Access Journals (Sweden)

    Ashley Miller

    2016-06-01

    Full Text Available Echocardiography is ideally suited to guide fluid resuscitation in critically ill patients. It can be used to assess fluid responsiveness by looking at the left ventricle, aortic outflow, inferior vena cava and right ventricle. Static measurements and dynamic variables based on heart–lung interactions all combine to predict and measure fluid responsiveness and assess response to intravenous fluid esuscitation. Thorough knowledge of these variables, the physiology behind them and the pitfalls in their use allows the echocardiographer to confidently assess these patients and in combination with clinical judgement manage them appropriately.

  1. Measurement of Thrombus Flux Using Transesophageal Echocardiography

    Science.gov (United States)

    Yamaguchi, Tadashi; Hirai, Kazuki; Aoki, Masami; Miyagi, Jin; Suzuki, Masahiko; Moriya, Hideshige; Hachiya, Hiroyuki

    2006-05-01

    Deep venous thrombosis (DVT) and pulmonary thromboembolism (PTE) are serious problem of total knee replacement (TKR). These diseases may be caused by a thrombus formed during the TKR operation. Therefore, understanding the flow volume of thrombus is important for curing and preventing PTE. In this paper, we tried to understanding the situation of the flow of thrombus by using transesophageal echocardiography movies. We applied the signal processing technique the FSET to extract the anomalous information from ultrasonic echo image. As a result of processing, the time change of the flow volume of thrombus was confirmed.

  2. Evaluation of commissural malalignment of aortic-pulmonary sinus using cardiac CT for arterial switch operation: comparison with transthoracic echocardiography

    International Nuclear Information System (INIS)

    Bang, Ji Hyun; Park, Jeong-Jun; Goo, Hyun Woo

    2017-01-01

    There are limited data regarding the influence of commissural malalignment of the aortic-pulmonary sinus on the arterial switch operation. To compare diagnostic accuracy between cardiac CT and echocardiography for evaluating commissural malalignment of aortic-pulmonary sinus in children with complete transposition of the great arteries and to seek potential clinical implication of commissural malalignment on the arterial switch operation. In 37 patients (35 boys; median age: 8 days, range: 3-80 days) with complete transposition of the great arteries who had tricuspid semilunar valves and underwent an arterial switch operation, the degree of the commissural rotation of the aortic-pulmonary sinus was assessed on cardiac CT (n=37) and echocardiography (n=35). With surgical finding as a reference, cardiac CT was compared with echocardiography in identifying commissural malalignment in 35 patients. The influence of the height difference between the semilunar valves measured by cardiac CT on the identification of commissural malalignment with cardiac CT and echocardiography was evaluated. The impact of commissural malalignment on coronary transfer techniques was evaluated. In operative findings, the commissures of the semilunar valves were aligned in 24 patients and malaligned in 13. With surgical findings as a reference, cardiac CT showed higher, but not statistically significant (P>0.05), sensitivity (91.7% vs. 75.0%), specificity (87.0% vs. 78.3%) and accuracy (88.6% vs. 77.1%) for the diagnosis of the malalignment than echocardiography. The measured height difference between the semilunar valves did not affect the identification of the malalignment with cardiac CT and echocardiography. The surgical malalignment group showed a higher requirement of modified coronary transfer techniques than the surgical aligned group (11/13 vs. 11/24, P=0.03). Cardiac CT and echocardiography appear useful for evaluating commissural malalignment of the semilunar valves in patients with

  3. Evaluation of commissural malalignment of aortic-pulmonary sinus using cardiac CT for arterial switch operation: comparison with transthoracic echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Ji Hyun; Park, Jeong-Jun [Asan Medical Center, University of Ulsan College of Medicine, Divisions of Pediatric Cardiac Surgery, Seoul (Korea, Republic of); Goo, Hyun Woo [Asan Medical Center, University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of)

    2017-05-15

    There are limited data regarding the influence of commissural malalignment of the aortic-pulmonary sinus on the arterial switch operation. To compare diagnostic accuracy between cardiac CT and echocardiography for evaluating commissural malalignment of aortic-pulmonary sinus in children with complete transposition of the great arteries and to seek potential clinical implication of commissural malalignment on the arterial switch operation. In 37 patients (35 boys; median age: 8 days, range: 3-80 days) with complete transposition of the great arteries who had tricuspid semilunar valves and underwent an arterial switch operation, the degree of the commissural rotation of the aortic-pulmonary sinus was assessed on cardiac CT (n=37) and echocardiography (n=35). With surgical finding as a reference, cardiac CT was compared with echocardiography in identifying commissural malalignment in 35 patients. The influence of the height difference between the semilunar valves measured by cardiac CT on the identification of commissural malalignment with cardiac CT and echocardiography was evaluated. The impact of commissural malalignment on coronary transfer techniques was evaluated. In operative findings, the commissures of the semilunar valves were aligned in 24 patients and malaligned in 13. With surgical findings as a reference, cardiac CT showed higher, but not statistically significant (P>0.05), sensitivity (91.7% vs. 75.0%), specificity (87.0% vs. 78.3%) and accuracy (88.6% vs. 77.1%) for the diagnosis of the malalignment than echocardiography. The measured height difference between the semilunar valves did not affect the identification of the malalignment with cardiac CT and echocardiography. The surgical malalignment group showed a higher requirement of modified coronary transfer techniques than the surgical aligned group (11/13 vs. 11/24, P=0.03). Cardiac CT and echocardiography appear useful for evaluating commissural malalignment of the semilunar valves in patients with

  4. Evaluation of a focussed protocol for hand-held echocardiography and computer-assisted auscultation in detecting latent rheumatic heart disease in scholars.

    Science.gov (United States)

    Zühlke, Liesl J; Engel, Mark E; Nkepu, Simpiwe; Mayosi, Bongani M

    2016-08-01

    Introduction Echocardiography is the diagnostic test of choice for latent rheumatic heart disease. The utility of echocardiography for large-scale screening is limited by high cost, complex diagnostic protocols, and time to acquire multiple images. We evaluated the performance of a brief hand-held echocardiography protocol and computer-assisted auscultation in detecting latent rheumatic heart disease with or without pathological murmur. A total of 27 asymptomatic patients with latent rheumatic heart disease based on the World Heart Federation criteria and 66 healthy controls were examined by standard cardiac auscultation to detect pathological murmur. Hand-held echocardiography using a focussed protocol that utilises one view - that is, the parasternal long-axis view - and one measurement - that is, mitral regurgitant jet - and a computer-assisted auscultation utilising an automated decision tool were performed on all patients. The sensitivity and specificity of computer-assisted auscultation in latent rheumatic heart disease were 4% (95% CI 1.0-20.4%) and 93.7% (95% CI 84.5-98.3%), respectively. The sensitivity and specificity of the focussed hand-held echocardiography protocol for definite rheumatic heart disease were 92.3% (95% CI 63.9-99.8%) and 100%, respectively. The test reliability of hand-held echocardiography was 98.7% for definite and 94.7% for borderline disease, and the adjusted diagnostic odds ratios were 1041 and 263.9 for definite and borderline disease, respectively. Computer-assisted auscultation has extremely low sensitivity but high specificity for pathological murmur in latent rheumatic heart disease. Focussed hand-held echocardiography has fair sensitivity but high specificity and diagnostic utility for definite or borderline rheumatic heart disease in asymptomatic patients.

  5. Specificity of Electrocardiography and Echocardiography Changes at the Patients with the Pulmonary Embolism

    Directory of Open Access Journals (Sweden)

    Amra Macić-Džanković

    2006-11-01

    Full Text Available We evaluated electrocardiographic and echocardiographic changes of 40 patients with pulmonary thrombo-embolism proved by perfusion scintigrams. ECG-changes included sinus tachycardia or absolute tachyarrhythmia de novo, changes type Q1S3T3 and changes in right precordial leads. Analyses of echocardiography included hyperkinesis and then dilatation and apical hypokinesis of right ventricule and tricuspid regurgitation with maximal transvalvular gradients. We emphasize such a sensibility of echocardiographic changes in early estimation of pulmonary thrombo-embolism severity and necessity for echocardiography as early as possible in suspected patients.

  6. Evaluation of an open access echocardiography service in the Netherlands: a mixed methods study of indications, outcomes, patient management and trends.

    Science.gov (United States)

    van Heur, Leanne M S G; Baur, Leo H B; Tent, Marleen; Lodewijks-van der Bolt, Cara L B; Streppel, Marjolijn; Winkens, Ron A G; Stoffers, Henri E J H

    2010-02-10

    In our region (Eastern South Limburg, The Netherlands) an open access echocardiography service started in 2002. It was the first service of this kind in The Netherlands. Our study aims were: (1) to evaluate demand for the service, participation, indications, echocardiography outcomes, and management by the general practitioner (GP); (2) to analyse changes in indications and outcomes over the years. (1) Data from GP request forms, echocardiography reports and a retrospective GP questionnaire on management (response rate 83%) of 625 consecutive patients (Dec. 2002-March 2007) were analysed cross-sectionally. (2) For the analysis of changes over the years, data from GP request forms and echocardiography reports of the first and last 250 patients that visited the service between Dec. 2002 and Feb. 2008 (n = 1001) were compared. The echocardiography service was used by 81% of the regional GPs. On average, a GP referred one patient per year to the service. Intended indications for the service were dyspnoea (32%), cardiac murmur (59%), and peripheral oedema (17%). Of the other indications (22%), one-third was for evaluation of suspected left ventricular hypertrophy (LVH). Expected outcomes were left ventricular dysfunction (LVD) (43%, predominantly diastolic) and valve disease (25%). We also found a high proportion of LVH (50%). Only 24% of all echocardiograms showed no relevant disease. The GP followed the cardiologist's advice to refer the patient for further evaluation in 71%. In recent patients, more echocardiography requests were done for 'cardiac murmur' and 'other' indications, but less for 'dyspnoea'. The proportions of patients with LVD, LVH and valve disease decreased and the proportion of patients with no relevant disease increased. The number of advices by the cardiologists increased. Overall, GPs used the open access echocardiography service efficiently (i.e. with a high chance of finding relevant pathology), but efficiency decreased slightly over the years

  7. Correlation of contrast-enhanced ultrasound parameters with oncogene expression and cell proliferation activity in breast cancer

    Institute of Scientific and Technical Information of China (English)

    Ce Zhang

    2017-01-01

    Objective: To study the correlation of contrast-enhanced ultrasound parameters with oncogene expression and cell proliferation activity in breast cancer. Methods: Breast cancer lesions and benign breast lesions surgically removed in Zigong Third People's Hospital between May 2014 and February 2017 were selected, contrast-enhanced ultrasound was done before operation to draw the time-intensity curve and calculate the area under the curve (AUC), and the expression of proliferation molecules and tumor suppressor genes were detected after operation. Results:The contrast-enhanced ultrasound parameter AUC of the breast cancer lesion was greatly higher than that of the benign breast lesion; ECT2, ZKSCAN3, USP39 and EphA2 mRNA expression in breast cancer lesions were obviously higher than those in benign breast lesions whereas HPK1, TCEAL17, CCN5, ATG2B and ATG4D mRNA expression were greatly lower than those in benign breast lesions; ECT2, ZKSCAN3, USP39 and EphA2 mRNA expression in breast cancer lesions with high AUC were greatly higher than those in breast cancer lesions with low AUC whereas HPK1, TCEAL17, CCN5, ATG2B and ATG4D mRNA expression were greatly lower than those in breast cancer lesions with low AUC. Conclusion: The contrast-enhanced ultrasound parameter AUC of breast cancer lesion significantly increases and is closely related to the higher expression of pro-proliferation molecules and the lower expression of tumor suppressor genes.

  8. Aortic root segmentation in 4D transesophageal echocardiography

    Science.gov (United States)

    Chechani, Shubham; Suresh, Rahul; Patwardhan, Kedar A.

    2018-02-01

    The Aortic Valve (AV) is an important anatomical structure which lies on the left side of the human heart. The AV regulates the flow of oxygenated blood from the Left Ventricle (LV) to the rest of the body through aorta. Pathologies associated with the AV manifest themselves in structural and functional abnormalities of the valve. Clinical management of pathologies often requires repair, reconstruction or even replacement of the valve through surgical intervention. Assessment of these pathologies as well as determination of specific intervention procedure requires quantitative evaluation of the valvular anatomy. 4D (3D + t) Transesophageal Echocardiography (TEE) is a widely used imaging technique that clinicians use for quantitative assessment of cardiac structures. However, manual quantification of 3D structures is complex, time consuming and suffers from inter-observer variability. Towards this goal, we present a semiautomated approach for segmentation of the aortic root (AR) structure. Our approach requires user-initialized landmarks in two reference frames to provide AR segmentation for full cardiac cycle. We use `coarse-to-fine' B-spline Explicit Active Surface (BEAS) for AR segmentation and Masked Normalized Cross Correlation (NCC) method for AR tracking. Our method results in approximately 0.51 mm average localization error in comparison with ground truth annotation performed by clinical experts on 10 real patient cases (139 3D volumes).

  9. Speckle reduction in echocardiography by temporal compounding and anisotropic diffusion filtering

    Science.gov (United States)

    Giraldo-Guzmán, Jader; Porto-Solano, Oscar; Cadena-Bonfanti, Alberto; Contreras-Ortiz, Sonia H.

    2015-01-01

    Echocardiography is a medical imaging technique based on ultrasound signals that is used to evaluate heart anatomy and physiology. Echocardiographic images are affected by speckle, a type of multiplicative noise that obscures details of the structures, and reduces the overall image quality. This paper shows an approach to enhance echocardiography using two processing techniques: temporal compounding and anisotropic diffusion filtering. We used twenty echocardiographic videos that include one or three cardiac cycles to test the algorithms. Two images from each cycle were aligned in space and averaged to obtain the compound images. These images were then processed using anisotropic diffusion filters to further improve their quality. Resultant images were evaluated using quality metrics and visual assessment by two medical doctors. The average total improvement on signal-to-noise ratio was up to 100.29% for videos with three cycles, and up to 32.57% for videos with one cycle.

  10. Cardiac Computed Tomography versus Echocardiography in the Assessment of Stenotic Rheumatic Mitral Valve.

    Science.gov (United States)

    Unal Aksu, Hale; Gorgulu, Sevket; Diker, Mustafa; Celik, Omer; Aksu, Huseyin; Ozturk, Derya; Kırıs, Adem; Kalkan, Ali Kemal; Erturk, Mehmet; Bakır, İhsan

    2016-03-01

    There are different clinical cardiac applications of dual source computed tomography (DSCT). Here, we aimed to compare the DSCT with the transthoracic echocardiography (TTE) for evaluating the Wilkins score and planimetric mitral valve area (MVA) of a rheumatic stenotic mitral valve. We prospectively evaluated mitral valvular structure and function in 31 patients with known mitral stenosis undergoing electrocardiogram-gated, second-generation DSCT, in our heart center for different indications. Mitral valve was evaluated using Wilkins score, and also, the planimetric MVA was assessed. We found a significant difference between MVAs determined by DSCT (average 1.42 ± 0.44 cm2) and MVAs determined by TTE (average 1.35 ± 0.43 cm2 ; difference 0.07 ± 0.16 cm2; P = 0.018). Linear regression analysis revealed a good correlation between the two techniques (r = 0.934; P < 0.0001). The limits of agreement for DSCT and TTE in the Bland-Altman analysis were ±0.31 cm2 . DSCT using TTE as the reference enabled good discrimination between mild and moderate-to-severe stenosis and had an area under the ROC curve of 0.967 (CI 0.912-1.023; P < 0.0001). Wilkins scores obtained by DSCT (7.51 ± 1.17, range 5-10) and TTE (8.16 ± 1.27, range 6-10) had a moderate correlation (r = 0.686; P < 0.0001). We found that planimetric MVA measurements assessed by DSCT were closely correlated with MVA calculations by TTE. The moderate correlation was observed for the Wilkins score. © 2015, Wiley Periodicals, Inc.

  11. A brief history of fetal echocardiography and its impact on the management of congenital heart disease.

    Science.gov (United States)

    Maulik, Dev; Nanda, Navin C; Maulik, Devika; Vilchez, Gustavo

    2017-12-01

    Congenital heart disease (CHD), the most common congenital malformation, is associated with adverse outcome. Development of fetal echocardiography has made prenatal diagnosis of CHD a reality, and in the process revolutionized its management. This historical review briefly narrates this development over the decades focusing on the emergence of the primary modalities of fetal echocardiography comprised of the time-motion mode, two-dimensional B-mode, spectral Doppler, color Doppler, and three- and four-dimensional cardiac imaging. Collaboration between clinicians and engineers has been central to these advances. Also discussed are the accuracy and impact of fetal echocardiography on the management of CHD, and especially its role in the prenatal diagnosis of critical CHD in individualizing the management and improving the outcome. Despite these advances, most cases of CHD are not identified prenatally, emphasizing the continuing need for further technological and educational innovation and improvement. © 2017, Wiley Periodicals, Inc.

  12. The modern role of transoesophageal echocardiography in the assessment of valvular pathologies

    Science.gov (United States)

    Bull, Sacha; Newton, James

    2017-01-01

    Despite significant advancements in the field of cardiovascular imaging, transoesophageal echocardiography remains the key imaging modality in the management of valvular pathologies. This paper provides echocardiographers with an overview of the modern role of TOE in the diagnosis and management of valvular disease. We describe how the introduction of 3D techniques has changed the detection and grading of valvular pathologies and concentrate on its role as a monitoring tool in interventional cardiology. In addition, we focus on the echocardiographic and Doppler techniques used in the assessment of prosthetic valves and provide guidance for the evaluation of prosthetic valves. Finally, we summarise quantitative methods used for the assessment of valvular stenosis and regurgitation and highlight the key areas where echocardiography remains superior over other novel imaging modalities. PMID:28096184

  13. The modern role of transoesophageal echocardiography in the assessment of valvular pathologies

    Directory of Open Access Journals (Sweden)

    Malgorzata Wamil MD PhD

    2017-03-01

    Full Text Available Despite significant advancements in the field of cardiovascular imaging, transoesophageal echocardiography remains the key imaging modality in the management of valvular pathologies. This paper provides echocardiographers with an overview of the modern role of TOE in the diagnosis and management of valvular disease. We describe how the introduction of 3D techniques has changed the detection and grading of valvular pathologies and concentrate on its role as a monitoring tool in interventional cardiology. In addition, we focus on the echocardiographic and Doppler techniques used in the assessment of prosthetic valves and provide guidance for the evaluation of prosthetic valves. Finally, we summarise quantitative methods used for the assessment of valvular stenosis and regurgitation and highlight the key areas where echocardiography remains superior over other novel imaging modalities.

  14. Sensibility and specificity of the stress echocardiography with Dobutamine for the detection of coronary disease

    International Nuclear Information System (INIS)

    Senior, Juan Manuel; Escobar, Carlos Ignacio; Jaramillo, Mario and others

    2001-01-01

    Dobutamine stress echocardiography has become a useful method for detecting coronary artery disease in the high prevalence population. The reported sensitivity varies between 76-90% and the specificity between 60-95%. 60-95% there have been few reports regarding sensitivity and specificity among our population. The aim of this study was to evaluate the sensitivity of dopamine stress echocardiography in a population with a high probability of coronary disease. This was a randomized retrospective-prospective study. Between February 1 of 1998 and February 1 of 1999. 409 patients underwent dopamine stress echocardiography and were analyzed according to established protocol. The Dobutamine stress echocardiography as well as the angiography was checked in a blind form by one of the participating researchers trained in those procedures. The diagnostic concordance was found to be greater than 90%. Significant coronary disease was considered to be present in those cases in which there was severe stenosis greater than 50% in a major epicardial artery or greater than 40 % in the left main artery. Coronary arteriography was performed within three months of Dobutamine stress echocardiography imaging. A sixteen-segment model was used as the index for the evaluation of systolic wall thickening and the results were classified as follows: normal (l), ischemia (ll), fixed abnormality (lll) and mixed (lV). 409 patients with an average age of 62.8 +/- 12) were included in the study at random. Six patients with mediocre technical examinations were excluded. 47 % were male. 29% had a history of myocardial infarction, 35 % had a history of arterial hypertension and 10% had diabetes mellitus. The average ejection fraction was 54 +/- 13%. The examination was prescribed in order to detect the presence of ischemia in 95.8% of the cases and as part of preoperative evaluation in 4.2 %. There were adverse effects in 40% of the cases; 15% of these were systemic and 25 % cardiac. The test was

  15. Prognostic value of stress echocardiography in women with high (⩾80%) probability of coronary artery disease

    OpenAIRE

    Davar, J; Roberts, E; Coghlan, J; Evans, T; Lipkin, D

    2001-01-01

    OBJECTIVE—To assess the prognostic significance of stress echocardiography in women with a high probability of coronary artery disease (CAD).
SETTING—Secondary and tertiary cardiology unit at a university teaching hospital.
PARTICIPANTS—A total of 135 women (mean (SD) age 63 (9) years) with pre-test probability of CAD ⩾80% were selected from a database of patients investigated by treadmill or dobutamine stress echocardiography between 1995 and 1998.
MAIN OUTCOME MEASURES—Patients were followe...

  16. Correlation between T2* cardiovascular magnetic resonance with left ventricular function and mass in adolescent and adult major thalassemia patients with iron overload.

    Science.gov (United States)

    Djer, Mulyadi M; Anggriawan, Shirley L; Gatot, Djajadiman; Amalia, Pustika; Sastroasmoro, Sudigdo; Widjaja, Patricia

    2013-10-01

    to assess for a correlation between T2*CMR with LV function and mass in thalassemic patients with iron overload. a cross-sectional study on thalassemic patients was conducted between July and September 2010 at Cipto Mangunkusumo and Premier Hospitals, Jakarta, Indonesia. Clinical examinations, review of medical charts, electrocardiography, echocardiography, and T2*CMR were performed. Cardiac siderosis was measured by T2*CMR conduction time. Left ventricle diastolic and systolic functions, as well as LV mass index were measured using echocardiography. Correlations between T2*CMR and echocardiography findings, as well as serum ferritin were determined using Pearson's and Spearman's tests. thirty patients aged 13-41 years were enrolled, of whom two-thirds had -thalassemia major and one-third had HbE/-thalassemia. Diastolic dysfunction was identified in 8 patients, whereas systolic function was normal in all patients. Increased LV mass index was found in 3 patients. T2*CMR conduction times ranged from 8.98 to 55.04 ms and a value below 20 ms was demonstrated in 14 patients. There was a statistically significant moderate positive correlation of T2*CMR conduction time with E/A ratio (r = 0.471, P = 0.009), but no correlation was found with LV mass index (r=0.097, P=0.608). A moderate negative correlation was found between T2*CMR and serum ferritin (r = -0.514, P = 0.004), while a moderate negative correlation was found between serum ferritin and E/A ratio (r = -0.425, P = 0.019). T2*CMR myocardial conduction time has a moderate positive correlation with diastolic function, moderate negative correlation with serum ferritin, but not with LV mass index and systolic function.

  17. The Heart of the Matter: Increasing Quality and Charge Capture from Intraoperative Transesophageal Echocardiography.

    Science.gov (United States)

    Sanford, Joseph A; Kadry, Bassam; Oakes, Daryl; Macario, Alex; Schmiesing, Cliff

    2016-04-15

    Although transesophageal echocardiography is routinely performed at our institution, there is no easy way to document the procedure in the electronic medical record and generate a bill compliant with reimbursement requirements. We present the results of a quality improvement project that used agile development methodology to incorporate intraoperative transesophageal echocardiography into the electronic medical record. We discuss improvements in the quality of clinical documentation, technical workflow challenges overcome, and cost and time to return on investment. Billing was increased from an average of 36% to 84.6% when compared with the same time period in the previous year. The expected recoupment of investment for this project is just 18 weeks.

  18. Comparison of neuroendocrine tumor detection and characterization using DOTATOC-PET in correlation with contrast enhanced CT and delayed contrast enhanced MRI

    International Nuclear Information System (INIS)

    Giesel, F.L.; Kratochwil, C.; Mehndiratta, A.; Wulfert, S.; Moltz, J.H.; Zechmann, C.M.; Kauczor, H.U.; Haberkorn, U.; Ley, S.

    2012-01-01

    Purpose: We evaluated the rate of successful characterization of gastroenteropancreatic neuroendocrine tumors (NETs) present with an increased somatostatin receptor, comparing CE-CT with CE-MRI, each in correlation with DOTATOC-PET. Methods and materials: 8 patients with GEP-NET were imaged using CE-MRI (Gd-EOB-DTPA), CE-CT (Imeron 400) and DOTATOC-PET. Contrast-enhancement of normal liver-tissue and metastasis was quantified with ROI-technique. Tumor delineation was assessed with visual-score in blind-read-analysis by two experienced radiologists. Results: Out of 40 liver metastases in patients with NETs, all were detected by CE-MRI and the lesion extent could be adequately assessed, whereas CT failed to detect 20% of all metastases. The blind-read-score of CT in arterial and portal phase was median −0.65 and −1.4, respectively, and 2.7 for delayed-MRI. The quantitative ROI-analysis presented an improved contrast-enhancement-ratio with a median of 1.2, 1.6 and 3.3 for CE-CT arterial, portal-phase and delayed-MRI respectively. Conclusion: Late CE-MRI was superior to CE-CT in providing additionally morphologic characterization and exact lesion extension of hepatic metastases from neuroendocrine tumor detected with DOTATOC-PET. Therefore, late enhanced Gd-EOB-DTPA-MRI seems to be the adequate imaging modality for combination with DOTATOC-PET to provide complementary (macroscopic and molecular) tumor characterization in hepatic metastasized NETs

  19. Elevational spatial compounding for enhancing image quality in echocardiography

    OpenAIRE

    Perperidis, Antonios; McDicken, Norman; MacGillivray, Tom; Anderson, Tom

    2016-01-01

    Introduction Echocardiography is commonly used in clinical practice for the real-time assessment of cardiac morphology and function. Nevertheless, due to the nature of the data acquisition, cardiac ultrasound images are often corrupted by a range of acoustic artefacts, including acoustic noise, speckle and shadowing. Spatial compounding techniques have long been recognised for their ability to suppress common ultrasound artefacts, enhancing the imaged cardiac structures. However, they require...

  20. Measurement of thrombus flux using transesophageal Echocardiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tadashi; Hirai, Kazuki; Aoki, Masami; Miyagi, Jin; Suzuki, Masahiko; Moriya, Hideshige; Hachiya Hiroyuki

    2006-01-01

    Deep venous thrombosis (DVT) and pulmonary thromboembolism (PTE) are serious problem of total knee replacement (TKR). These diseases may be caused by a thrombus formed during the TKR operation. Therefore, understanding the flow volume of thrombus is important for curing and preventing PTE. In this paper, we tried to understanding the situation of the flow of thrombus by using transesophageal echocardiography movies. We applied the signal processing technique the fiber structure extraction technique (FSET) to extract the anomalous information from ultrasonic echo image. As a result of processing, the time change of the flow volume of thrombus was confirmed. (author)

  1. Clinical assessment of heart chamber size and valve motion during cardiopulmonary resuscitation by two-dimensional echocardiography.

    Science.gov (United States)

    Rich, S; Wix, H L; Shapiro, E P

    1981-09-01

    It has been generally accepted that enhanced blood flow during closed-chest CPR is generated from compression of the heart between the sternum and the spine. To visualize the heart during closed-chest massage, we performed two-dimensional echocardiography (2DE) during resuscitation efforts in four patients who had cardiac arrest. 2DE analysis showed that (1) the LV internal dimensions did not change appreciably with chest compression; (2) the mitral and aortic valves were open simultaneously during the compression phase; (3) blood flow into the right heart, as evidenced by saline bubble contrast, occurred during the relaxation phase; and (4) compression of the right ventricle and LA occurred in varying amounts in all patients. We conclude that stroke volume from the heart during CPR does not result from compression of the LV. Rather, CPR-induced improved cardiocirculatory dynamics appear to be principally the result of changes in intrathoracic pressure created by sternal compression.

  2. In vivo dentate nucleus MRI relaxometry correlates with previous administration of Gadolinium-based contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Tedeschi, Enrico; Canna, Antonietta; Cocozza, Sirio; Russo, Carmela; Angelini, Valentina; Brunetti, Arturo [University ' ' Federico II' ' , Neuroradiology, Department of Advanced Biomedical Sciences, Naples (Italy); Palma, Giuseppe; Quarantelli, Mario [National Research Council, Institute of Biostructure and Bioimaging, Naples (Italy); Borrelli, Pasquale; Salvatore, Marco [IRCCS SDN, Naples (Italy); Lanzillo, Roberta; Postiglione, Emanuela; Morra, Vincenzo Brescia [University ' ' Federico II' ' , Department of Neurosciences, Reproductive and Odontostomatological Sciences, Naples (Italy)

    2016-12-15

    To evaluate changes in T1 and T2* relaxometry of dentate nuclei (DN) with respect to the number of previous administrations of Gadolinium-based contrast agents (GBCA). In 74 relapsing-remitting multiple sclerosis (RR-MS) patients with variable disease duration (9.8±6.8 years) and severity (Expanded Disability Status Scale scores:3.1±0.9), the DN R1 (1/T1) and R2* (1/T2*) relaxation rates were measured using two unenhanced 3D Dual-Echo spoiled Gradient-Echo sequences with different flip angles. Correlations of the number of previous GBCA administrations with DN R1 and R2* relaxation rates were tested, including gender and age effect, in a multivariate regression analysis. The DN R1 (normalized by brainstem) significantly correlated with the number of GBCA administrations (p<0.001), maintaining the same significance even when including MS-related factors. Instead, the DN R2* values correlated only with age (p=0.003), and not with GBCA administrations (p=0.67). In a subgroup of 35 patients for whom the administered GBCA subtype was known, the effect of GBCA on DN R1 appeared mainly related to linear GBCA. In RR-MS patients, the number of previous GBCA administrations correlates with R1 relaxation rates of DN, while R2* values remain unaffected, suggesting that T1-shortening in these patients is related to the amount of Gadolinium given. (orig.)

  3. Quantitative structure-property relationship (correlation analysis) of phosphonic acid-based chelates in design of MRI contrast agent.

    Science.gov (United States)

    Tiwari, Anjani K; Ojha, Himanshu; Kaul, Ankur; Dutta, Anupama; Srivastava, Pooja; Shukla, Gauri; Srivastava, Rakesh; Mishra, Anil K

    2009-07-01

    Nuclear magnetic resonance imaging is a very useful tool in modern medical diagnostics, especially when gadolinium (III)-based contrast agents are administered to the patient with the aim of increasing the image contrast between normal and diseased tissues. With the use of soft modelling techniques such as quantitative structure-activity relationship/quantitative structure-property relationship after a suitable description of their molecular structure, we have studied a series of phosphonic acid for designing new MRI contrast agent. Quantitative structure-property relationship studies with multiple linear regression analysis were applied to find correlation between different calculated molecular descriptors of the phosphonic acid-based chelating agent and their stability constants. The final quantitative structure-property relationship mathematical models were found as--quantitative structure-property relationship Model for phosphonic acid series (Model 1)--log K(ML) = {5.00243(+/-0.7102)}- MR {0.0263(+/-0.540)}n = 12 l r l = 0.942 s = 0.183 F = 99.165 quantitative structure-property relationship Model for phosphonic acid series (Model 2)--log K(ML) = {5.06280(+/-0.3418)}- MR {0.0252(+/- .198)}n = 12 l r l = 0.956 s = 0.186 F = 99.256.

  4. Myocardial perfusion assessed by contrast echocardiography and single photon emission computed tomography in the evaluation of patients with acute chest pain and normal electrocardiogram

    International Nuclear Information System (INIS)

    Soares, J. Jr.; Ferreira, S.M.A.; Matias, W. Jr.; Giorgi, M.C.P.; Izaki, M.; Luz, P.L.; Ramires, J.A.F.; Meneghetti, J.C.

    2002-01-01

    Aim : Evaluation of diagnostic accuracy of myocardial contrast echocardiography (MCE) in comparison with single-photon emission computed tomography (SPECT) for the detection of myocardial ischemia in patients with acute chest pain. Material and Methods : Eighteen patients (pts) with chest pain lasting ≥30 minutes, occurring within 6 hours of emergency room presentation and a normal or no diagnostic electrocardiogram were studied. Pts underwent rest MCE and SPECT. For both exams myocardial perfusion was assessed in the same 7 segments (apical, anterior, inferior, anteroseptal, inferoseptal, lateral and posterior) of left ventricle. A total of 126 segments were analyzed. Images were classified as positive for ischemia if they had a perfusion defect. Coronary angiography was performed if MCE or SPECT images were classified as positive for ischemia or by clinical indication. Otherwise the patients underwent stress SPECT. Significant coronary artery disease (CAD) was defined as ≥70% stenosis in a major coronary artery or its branches. Final diagnosis of an acute coronary event (ACE) was established in the presence of positive findings in MCE or SPECT in addition to significant CAD in the corresponding territory. Kappa statistics were calculated to evaluate the concordance between MCE and SPECT. κ values of ≤0.4, >0.4 and >0.7 indicate fair, good and excellent agreement, respectively. Results: Thirteen out of 18 pts underwent coronary angiography (seven pts had positive findings on SPECT, 2 on MCE, 2 on both exams and 1 had clinical indication). Significant CAD was detected on six. Five pts underwent stress SPECT and no perfusion defect was detected. Therefore, six pts (33.3%) had an ACE and 12 (66.6%) had not. There were no statistical differences between groups according to age, gender, duration of pain, free pain interval, presence of risk factors and antecedents. Concordance between MCE and SPECT for evaluation of perfusion defects showed a ? coefficient of 0

  5. Evaluation of an open access echocardiography service in the Netherlands: a mixed methods study of indications, outcomes, patient management and trends

    Directory of Open Access Journals (Sweden)

    Streppel Marjolijn

    2010-02-01

    Full Text Available Abstract Background In our region (Eastern South Limburg, The Netherlands an open access echocardiography service started in 2002. It was the first service of this kind in The Netherlands. Our study aims were: (1 to evaluate demand for the service, participation, indications, echocardiography outcomes, and management by the general practitioner (GP; (2 to analyse changes in indications and outcomes over the years. Methods (1 Data from GP request forms, echocardiography reports and a retrospective GP questionnaire on management (response rate 83% of 625 consecutive patients (Dec. 2002 - March 2007 were analysed cross-sectionally. (2 For the analysis of changes over the years, data from GP request forms and echocardiography reports of the first and last 250 patients that visited the service between Dec. 2002 and Feb. 2008 (n = 1001 were compared. Results The echocardiography service was used by 81% of the regional GPs. On average, a GP referred one patient per year to the service. Intended indications for the service were dyspnoea (32%, cardiac murmur (59%, and peripheral oedema (17%. Of the other indications (22%, one-third was for evaluation of suspected left ventricular hypertrophy (LVH. Expected outcomes were left ventricular dysfunction (LVD (43%, predominantly diastolic and valve disease (25%. We also found a high proportion of LVH (50%. Only 24% of all echocardiograms showed no relevant disease. The GP followed the cardiologist's advice to refer the patient for further evaluation in 71%. In recent patients, more echocardiography requests were done for 'cardiac murmur' and 'other' indications, but less for 'dyspnoea'. The proportions of patients with LVD, LVH and valve disease decreased and the proportion of patients with no relevant disease increased. The number of advices by the cardiologists increased. Conclusion Overall, GPs used the open access echocardiography service efficiently (i.e. with a high chance of finding relevant pathology

  6. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  7. Current and future role of echocardiography in arrhythmogenic right ventricular dysplasia/cardiomyopathy

    NARCIS (Netherlands)

    Mast, Thomas P.; Teske, Arco J.; Doevendans, Pieter A.; Cramer, Maarten J.

    Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is an inherited progressive cardiomyopathy, clinically characterized by ventricular arrhythmias and increased risk of sudden cardiac death. Echocardiography has a role in the diagnosis and prognosis of ARVD/C. However, in the current

  8. ADDITIVE VALUE OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THE VISUALIZATION OF CARCINOID HEART-DISEASE

    NARCIS (Netherlands)

    VANVELDHUISEN, DJ; HAMER, JPM; ANDRIESSEN, MPHM; DEVRIES, EGE; LIE, KI

    A 65-yr-old woman with atypical complaints and a tricuspid insufficiency murmur underwent transthoracic echocardiography, which showed right-sided abnormalities, but did not allow clear visualization of the valves. Subsequent transoesophageal imaging, however, raised the suspicion of carcinoid heart

  9. Automatic assessment of mitral regurgitation severity based on extensive textural features on 2D echocardiography videos.

    Science.gov (United States)

    Moghaddasi, Hanie; Nourian, Saeed

    2016-06-01

    Heart disease is the major cause of death as well as a leading cause of disability in the developed countries. Mitral Regurgitation (MR) is a common heart disease which does not cause symptoms until its end stage. Therefore, early diagnosis of the disease is of crucial importance in the treatment process. Echocardiography is a common method of diagnosis in the severity of MR. Hence, a method which is based on echocardiography videos, image processing techniques and artificial intelligence could be helpful for clinicians, especially in borderline cases. In this paper, we introduce novel features to detect micro-patterns of echocardiography images in order to determine the severity of MR. Extensive Local Binary Pattern (ELBP) and Extensive Volume Local Binary Pattern (EVLBP) are presented as image descriptors which include details from different viewpoints of the heart in feature vectors. Support Vector Machine (SVM), Linear Discriminant Analysis (LDA) and Template Matching techniques are used as classifiers to determine the severity of MR based on textural descriptors. The SVM classifier with Extensive Uniform Local Binary Pattern (ELBPU) and Extensive Volume Local Binary Pattern (EVLBP) have the best accuracy with 99.52%, 99.38%, 99.31% and 99.59%, respectively, for the detection of Normal, Mild MR, Moderate MR and Severe MR subjects among echocardiography videos. The proposed method achieves 99.38% sensitivity and 99.63% specificity for the detection of the severity of MR and normal subjects. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Coronary artery size and origin imaging in children: a comparative study of MRI and trans-thoracic echocardiography

    International Nuclear Information System (INIS)

    Hussain, Tarique; Mathur, Sujeev; Peel, Sarah A.; Valverde, Israel; Bilska, Karolina; Henningsson, Markus; Botnar, Rene M.; Simpson, John; Greil, Gerald F.

    2015-01-01

    The purpose of this study was to see how coronary magnetic resonance angiography (CMRA) compared to echocardiography for the detection of coronary artery origins and to compare CMRA measurements for coronary dimensions in children with published echocardiographic reference values. Enrolled patients underwent dual cardiac phase CMRA and echocardiography under the same anesthetic. Echocardiographic measurements of the right coronary artery (RCA), left anterior descending (LAD) and left main (LM) were made. CMRA dimensions were assessed manually at the same points as the echocardiographic measurements. The number of proximal LAD branches imaged was also recorded in order to give an estimate of distal coronary tree visualization. Fifty patients (24 boys, mean age 4.0 years (range 18 days to 18 years)) underwent dual-phase CMRA. Coronary origins were identified in 47/50 cases for CMRA (remaining 3 were infants aged 3, 9 and 11 months). In comparison, origins were identified in 41/50 cases for echo (remaining were all older children). CMRA performed better than echocardiography in terms of distal visualization of the coronary tree (median 1 LAD branch vs. median 0; p = 0.001). Bland-Altman plots show poor agreement between echocardiography and CMRA for coronary measurements. CMRA measurements did vary according to cardiac phase (systolic mean 1.90, s.d. 0.05 mm vs. diastolic mean 1.84, s.d. 0.05 mm; p = 0.002). Dual-phase CMRA has an excellent (94 %) success rate for the detection of coronary origins in children. Newborn infants remain challenging and echocardiography remains the accepted imaging modality for this age group. Echocardiographic reference ranges are not applicable to CMRA measurements as agreement was poor between modalities. Future coronary reference values, using any imaging modality, should quote the phase in which it was measured

  11. Speckle tracking echocardiography in mature Irish Wolfhound dogs

    DEFF Research Database (Denmark)

    Westrup, Ulrik; McEvoy, Fintan

    2013-01-01

    Two-dimensional strain measurements obtained by speckle tracking echocardiography (STE) have been reported in both humans and dogs. Incorporation of this technique into canine clinical practice requires the availability of measurements from clinically normal dogs, ideally of the same breed, taken...... under normal clinical conditions.The aims of this prospective study were to assess if it is possible to obtain STE data during a routine echocardiographic examination in Irish Wolfhound dogs and that these data will provide reference values and an estimation of measurement error....

  12. Arterial Stiffness and its Correlation with the Extent of Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Hourak Poorzand

    2018-06-01

    Full Text Available Introduction: Coronary artery disease secondary to atherosclerosis is the most common cause of mortality. Coronary angiography is the most precise method for determining the extent of disease in the coronary vascular bed. Arterial stiffness has been proposed as a marker of atherosclerosis in some studies. One of the noninvasive methods for the determination of arterial stiffness is Doppler echocardiography. In this study, we aimed to find the correlation between arterial stiffness as measured by echocardiography and the extent of coronary artery disease as evaluated through angiography. Materials and Methods: Aortic pulse wave velocity (APWV was measured by using the Doppler method in 70 patients, who were candidates for coronary angiography. The extent of coronary artery disease was determined quantitatively in terms of Friesinger index and semi-quantitatively as the number of vessels with stenosis of over 50%. Then, the correlation between arterial stiffness and these factors was evaluated. Results: The mean APWV was 9.1±5 m/s. There was a direct relationship between APWV and Friesinger index, which was not statistically significant (P=0.67. The mean APWV for patients with one-vessel disease was 4.4±1.8 m/s, while it was 9.9±3.6 m/s in patients with two and 7.9±4 m/s in three-vessel disease which did not show statistically significant difference. Conclusion: Doppler echocardiography to measure APWV was not considered as a promising tool to predict the extent of coronary artery disease.

  13. Off-pump atrial septostomy with thoracoscopic scissors under transesophageal echocardiography guidance

    Directory of Open Access Journals (Sweden)

    Raj R Benedict

    2013-01-01

    Full Text Available Selected children with congenital heart defects undergoing palliative closed heart procedures require a cardiopulmonary bypass (CPB run only for the purpose of creating an inter-atrial communication. We report a simple technique of atrial septostomy using thoracoscopy scissors under transesophageal echocardiography guidance without the need for CPB.

  14. A systematic method for using 3D echocardiography to evaluate tricuspid valve insufficiency in hypoplastic left heart syndrome

    OpenAIRE

    Mart, Christopher Robin; Eckhauser, Aaron Wesley; Murri, Michael; Su, Jason Thomas

    2014-01-01

    With surgical palliation of hypoplastic left heart syndrome (HLHS), the tricuspid valve (TV) becomes the systemic atrioventricular valve and moderate/severe TV insufficiency (TVI), an adverse risk factor for survival to Fontan, has been reported in up to 35% of patients prior to stage I palliation. Precise echocardiographic identification of the mechanism of TVI cannot be determined by two-dimensional echocardiography. Three-dimensional echocardiography (3DE) can provide significant insight i...

  15. Archeological Echocardiography: Digitization and Speckle-Tracking Analysis of Archival Echocardiograms in the HyperGEN Study

    Science.gov (United States)

    Aguilar, Frank G.; Selvaraj, Senthil; Martinez, Eva E.; Katz, Daniel H.; Beussink, Lauren; Kim, Kwang-Youn A.; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R.; Arnett, Donna K.; Shah, Sanjiv J.

    2015-01-01

    Background Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle-tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. Methods In the NHLBI HyperGEN study (N=2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter/intraobserver agreement was calculated. Accuracy was evaluated in (1) a separate second study (N=50) comparing prospective digital strain vs. post-hoc analog-to-digital strain; and (2) in a third study (N=95) comparing prospectively-obtained TDI e′ velocities with post-hoc STE e′ velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Results Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intraobserver agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post-hoc STE to prospective digital STE for strain analysis. STE-derived e′ velocities correlated with, but systematically underestimated, TDI e′ velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β =−2.4 [95% CI −3.6,−1.2]% per 1-SD increase in fasting glucose; Pechocardiography, the digitization and speckle-tracking analysis of archival echocardiograms, is feasible and generates parameters of cardiac mechanics similar to contemporary studies. PMID

  16. Contrast enhanced MR findings of lesions associated with radial scar: correlation with histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Jee Woo; Cha, Eun Suk; Choi, Hyun Joo; Seo, Young Jin [College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of)

    2007-01-15

    To evaluate the contrast-enhanced MR findings of lesions associated with a radial scar and to compare the MR findings with the histopathology results. From Mar. 2001 to Sep. 2005, 8 patients with a surgically proven radial scar who had undergone MRI, mammography, and ultrasonography were enrolled in this study. The morphological findings and dynamic enhancement pattern of the time-intensity curve were retrospectively reviewed using noncontrast and contrast-enhanced MRI. Mammography and ultrasonography were also analyzed according to the BI-RADS category and correlated with the histopathological diagnosis. The age of the patients ranged from 42 to 53 years (mean, 47 years). Five patients presented with a left breast lesion and the others presented with a right breast lesion. The histopathological diagnosis associated with the radial scar were fibrocystic changes (n = 1) adenosis (n = 2), atypical ductal hyperplasia (n = 2), lobular carcinoma in situ (n = 1), ductal carcinoma in situ (n = 1), and invasive ductal carcinoma (n = 1). In all patients, architectural distortion without microcalcification was observed with mammography. Irregular shaped hypoechoic lesions with an indistinct, spiculated, or angular margin was observed in all patients with ultrasonography. Posterior shadowing was observed in 4 cases. MR enhancement revealed two cases with foci enhancement (adenosis and fibrocystic change), five cases with non-mass-like focal enhancement (fibrocystic change, atypical ductal hyperplasia, lobular carcinoma in situ, ductal carcinoma in situ, invasive ductal carcinoma), and one irregular homogeneous mass enhancement (atypical ducal hyperplasia). The time-signal intensity curves are as follows: persistent type (n = 2), adenosis, and fibrocystic changes, respectively; plateu type (n = 4) one adenosis, two atypical ductal hyperplasia, and one ductal carcinoma in situ; and washout type (n = 2), lobular carcinoma in situ, and invasive ductal carcinoma, respectively

  17. Contrast enhanced MR findings of lesions associated with radial scar: correlation with histopathology

    International Nuclear Information System (INIS)

    Chung, Jee Woo; Cha, Eun Suk; Choi, Hyun Joo; Seo, Young Jin

    2007-01-01

    To evaluate the contrast-enhanced MR findings of lesions associated with a radial scar and to compare the MR findings with the histopathology results. From Mar. 2001 to Sep. 2005, 8 patients with a surgically proven radial scar who had undergone MRI, mammography, and ultrasonography were enrolled in this study. The morphological findings and dynamic enhancement pattern of the time-intensity curve were retrospectively reviewed using noncontrast and contrast-enhanced MRI. Mammography and ultrasonography were also analyzed according to the BI-RADS category and correlated with the histopathological diagnosis. The age of the patients ranged from 42 to 53 years (mean, 47 years). Five patients presented with a left breast lesion and the others presented with a right breast lesion. The histopathological diagnosis associated with the radial scar were fibrocystic changes (n = 1) adenosis (n = 2), atypical ductal hyperplasia (n = 2), lobular carcinoma in situ (n = 1), ductal carcinoma in situ (n = 1), and invasive ductal carcinoma (n = 1). In all patients, architectural distortion without microcalcification was observed with mammography. Irregular shaped hypoechoic lesions with an indistinct, spiculated, or angular margin was observed in all patients with ultrasonography. Posterior shadowing was observed in 4 cases. MR enhancement revealed two cases with foci enhancement (adenosis and fibrocystic change), five cases with non-mass-like focal enhancement (fibrocystic change, atypical ductal hyperplasia, lobular carcinoma in situ, ductal carcinoma in situ, invasive ductal carcinoma), and one irregular homogeneous mass enhancement (atypical ducal hyperplasia). The time-signal intensity curves are as follows: persistent type (n = 2), adenosis, and fibrocystic changes, respectively; plateu type (n = 4) one adenosis, two atypical ductal hyperplasia, and one ductal carcinoma in situ; and washout type (n = 2), lobular carcinoma in situ, and invasive ductal carcinoma, respectively

  18. Complementary roles of m-mode echocardiography and scintigraphy in the evaluation of adults wih suspected left-to-right shunts

    International Nuclear Information System (INIS)

    Botvinick, E.H.; Schiller, N.B.

    1980-01-01

    We sought to determine the relative clinical abilities and roles of echocardiography and scintigraphy in left-to-right shunt diagnosis. M-mode echocardiographic and scintigraphic studies were analyzed in 37 adults presenting diagnostic difficulties with suspected left-to-right shunts. An enlarged right ventricle on M-mode echocardiography was a sensitive (100%) but not specific (55%) indicator of atrial septal defect (ASD). M-mode lacked sensitivity for ventricular eptal defect (VSD) and patent ductus arteriosus (PDA). In a few studies, two-dimensional echocardiography provided additional specific and clinically important anatomic information. Scintigraphic analysis demonstrated complete diagnostic accuracy and excellent localizing and quantitative abilities in all patients studied. Because it is extremely sensitie to ASD, free of any exposure to radioactivity, entirely noninvasive and may by simply and visually analyzed, echocardiography is the study of choice in the preliminary evaluation of patients presenting, diagnostic difficulty with suspected ASD. Scintigraphy is the study of choice in the preliminary evaluation of patients presenting diagnostic difficulty with suspected VSD and PDA and is the logical response to the finding of echocardiographic right ventricular enlargement when the diagnosis remains in doubt

  19. Advanced quantitative echocardiography in arrhythmogenic right ventricular cardiomyopathy

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Hastrup Svendsen, Jesper; Sogaard, Peter

    2007-01-01

    BACKGROUND: Arrhythmogenic right ventricular (RV) cardiomyopathy (ARVC) is a regional disease of the RV myocardium with variable degrees of left ventricular involvement. Three-dimensional echocardiography and Doppler tissue imaging (DTI) are new echocardiographic modalities for the evaluation......, patients with ARVC had a decreased RV ejection fraction (0.47 +/- 0.08 vs 0.53 +/- 0.05, P vs 15.1 +/- 3.7 cm/s, P left ventricle (7.0 +/- 2.6 vs 9.5 +/- 1.9 cm/s, P ... of the longitudinal motility appears to be a sensitive marker of preclinical left ventricular involvement....

  20. Successful surgical removal of the large retrocardiac mass. The usefulness of CT scan and intraoperative echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, Minoru; Abe, Toshio; Murase, Mitsuya; Nogaki, Hideitsu; Takeuchi, Eiji (Nagoya Univ. (Japan). Faculty of Medicine)

    1983-04-01

    Computed tomography had proved useful in identifying cardiac lesion, especially space taking lesion. A 53-year-old man, who had open mitral commissurotomy eight years ago, has been regarded as the patient with an unresectable tumor of the left ventricle by echocardiography during about five years before this operation. However, the finding of cardiac CT scan in this patient led to excision of the mass. The patient was operated on through the left fifth intercostal space incision without extracorporeal circulation. The pericardium was densely adherent to the heart. We could not tell the border between the mass and the myocardium. Therefore, it was too difficult to incise the mass without injury to the myocardium or the coronary artery. After embarrassment, intraoperative echocardiography was performed. Intraoperative echocardiography demonstrated the size and the location of the mass, and its relation to the myocardiom, which resulted in successful removal of the mass. The removed mass was old hematoma of 300 gr in weight. In this paper, the usefulness of CT and intraoperative echocardiograpy was described and the origin of this hematoma was discussed.

  1. Iron Deficiency in COPD Associates with Increased Pulmonary Artery Pressure Estimated by Echocardiography

    DEFF Research Database (Denmark)

    Plesner, Louis L; Schoos, Mikkel M; Dalsgaard, Morten

    2017-01-01

    OBJECTIVES: Iron deficiency (ID) might augment chronic pulmonary hypertension in chronic obstructive pulmonary disease (COPD). This observational study investigates the association between ID and systolic pulmonary artery pressure estimated by echocardiography in non-anaemic COPD outpatients...

  2. Improved identification of viable myocardium using second harmonic imaging during dobutamine stress echocardiography

    NARCIS (Netherlands)

    F. Sozzi (Fabiola); D. Poldermans (Don); J.J. Bax (Jeroen); A. Elhendy (Abdou); E.C. Vourvouri (Eleni); R. Valkema (Roelf); J. de Sutter; A.F.L. Schinkel (Arend); A. Borghetti; J.R.T.C. Roelandt (Jos)

    2001-01-01

    textabstractOBJECTIVE: To determine whether, compared with fundamental imaging, second harmonic imaging can improve the accuracy of dobutamine stress echocardiography for identifying viable myocardium, using nuclear imaging as a reference. PATIENTS: 30 patients with chronic left

  3. Two-dimensional color Doppler echocardiography for left ventricular stroke volume assessment: a comparison study with three-dimensional echocardiography.

    Science.gov (United States)

    Silva, Cristina Da; Pedro, Fátima; Deister, Lizandra; Sahlén, Anders; Manouras, Aristomenis; Shahgaldi, Kambiz

    2012-08-01

    Whether measurement of left ventricular outflow tract diameter (LVOTd) using color Doppler (CD) in order to more accurately define LVOTd is more accurate for determination of stroke volume (SV) than gray scale and compare it with direct measurement of LVOT area (a) using three-dimensional echocardiography (3DE) for SV determination. Twenty-one volunteers were examined. LVOTa was calculated by two-dimensional echocardiography (2DE) using the following formula: π× (d/2)(2) , d = LVOT diameter by gray scale and CD, respectively. Planimetry of LVOTa was performed in parasternal long axis using 3DE. Eccentricity Index was calculated using the lateral and anterior-posterior LVOTd. SV was obtained by four different methods: (1) 2D gray scale, (2) 2D color, (3) LVOTa × LVOT velocity time integral, and (4) SV by Simpson's biplane method. Gray scale LVOTd was significantly smaller compared to LVOTd obtained with CD (P vs 3.67 ± 0.70 cm(2) , P vs 3.61 ± 0.89 cm(2) , P = 0.011). Half of the subjects had at least 17% difference between the lateral and anterior-posterior LVOTd. There were significant differences between SV by 2D gray scale and 2D CD (82.8 ± 17.1 mL vs 92.4 ± 16.8 mL, P vs 90.7 ± 19.8 mL, P = 0.025). Our study demonstrates LVOT being frequently elliptical. SV and LVOTa were found to be similar when comparing 2DE CD and 3DE planimetry and showed higher values in comparison to 2DE gray scale, which suggests 2DE CD to be an alternative approach for SV assessment. © 2012, Wiley Periodicals, Inc.

  4. Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.

    Science.gov (United States)

    Yu, Lifeng; Chen, Baiyu; Kofler, James M; Favazza, Christopher P; Leng, Shuai; Kupinski, Matthew A; McCollough, Cynthia H

    2017-08-01

    Model observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e., multislice reading). The purpose of this study was to correlate human and model observer performance in a low-contrast detection task performed using both 2D and multislice reading, and to determine if the 2D model observer still correlate well with human observer performance in multislice reading. A phantom containing 18 low-contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192-slice CT scanner at five dose levels (CTDI vol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered-backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side-by-side with a signal-absent VOI to create a 2-alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multislice channelized Hotelling observer (CHO_MS), which integrates multislice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multislice viewing performance and the two CHO models. Human observer performance was well correlated with the CHO_2D performance in the 2D viewing mode [Pearson product-moment correlation coefficient R = 0.972, 95% confidence

  5. Incremental Value of Three-Dimensional Transesophageal Echocardiography over the Two-Dimensional Technique in the Assessment of a Thrombus in Transit through a Patent Foramen Ovale.

    Science.gov (United States)

    Thind, Munveer; Ahmed, Mustafa I; Gok, Gulay; Joson, Marisa; Elsayed, Mahmoud; Tuck, Benjamin C; Townsley, Matthew M; Klas, Berthold; McGiffin, David C; Nanda, Navin C

    2015-05-01

    We report a case of a right atrial thrombus traversing a patent foramen ovale into the left atrium, where three-dimensional transesophageal echocardiography provided considerable incremental value over two-dimensional transesophageal echocardiography in its assessment. As well as allowing us to better spatially characterize the thrombus, three-dimensional transesophageal echocardiography provided a more quantitative assessment through estimation of total thrombus burden. © 2015, Wiley Periodicals, Inc.

  6. Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report.

    Science.gov (United States)

    Nakahira, Junko; Ishii, Hisanari; Sawai, Toshiyuki; Minami, Toshiaki

    2015-03-07

    Fibrin glue is used commonly during cardiac surgery but can behave as an intracardiac abnormal foreign body following surgery. There have been few such cases reported, and they were typically noticed only because of the resulting catastrophic cardiac conditions, such as valvular malfunction. We report a case where, for the first time, transesophageal echocardiography was used to detected fibrin glue that was adherent to the ventricular side of a patient's aortic valve immediately after aortic declamping. A 45-year-old Japanese man with Marfan syndrome underwent an aortic valve-sparing operation to treat moderate aortic valve regurgitation resulting from enlargement of his right coronary cusp. Fibrin glue was lightly applied to the suture line between the previous and new grafts. Transesophageal echocardiography performed prior to weaning from the cardiopulmonary bypass revealed mild aortic valve regurgitation in addition to a mobile membranous structure attached to the ventricular side of his aortic valve. It was identified as fibrin glue. We resolved the regurgitation by removing the fibrin glue and repeating the aortic cusp plication. The patient had no complications during recovery. Fibrin glue can act as an intracardiac foreign body and lead to a potentially fatal embolism. We demonstrated the use of transesophageal echocardiography to detect a fibrin glue-derived intracardiac abnormal foreign body and to confirm its removal. To the best of our knowledge, this is the first case where fibrin glue adherent to the aortic valve was detected by transesophageal echocardiography. These findings demonstrate the importance of using transesophageal echocardiography during cardiac surgery that involves using biological glues.

  7. Magnetic resonance pharmacological stress for detecting coronary disease. Comparison with echocardiography

    International Nuclear Information System (INIS)

    Baer, F.M.; Crnac, J.; Jochims, M.; Schneider, C.; Erdmann, E.; Schmidt, M.; Theissen, P.; Schicha, H.

    2000-01-01

    Stress testing is the cornerstone in the diagnosis of patients with suspected coronary artery disease (CAD). Although exercise ECG remains the primary approach for the detection of ischemia in patients with chest pain syndromes, its sensitivity and specificity is limited and exercise ECG does not provide detailed information about the localisation and extent of CAD. Stress echocardiography has been used for the detection of ischemia for more than a decade and has become an increasingly popular noninvasive method for the detection of CAD. In experienced hands wall motion analysis based on stress echocardiography has proved to be as sensitive and specific for the detection of myocardial ischemia as scintigraphic techniques. Recent technical improvements, namely the availability of ultrafast imaging sequences with a significant reduction of imaging time have initiated several studies which examined the combination of pharmacological stress and magnetic resonance imaging (MRI) for the detection of suspected CAD. The most well developed stress-MRI technique is wall motion imaging during dobutamine stress. This technique is analogous to stress echocardiography, but MRI has the inherent advantages of better resolution, higher reproducibility and true long and short axis imaging with contiguous parallel slices. However, the clinical impact of MRI for the diagnosis of CAD is still low. Further technical developments including real time imaging and a reliable automated quantitative analysis of left ventricular function are required before stress-MRI becomes a serious challenge to stressechocardiography in the clinical arena. Currently, only a few MRI facilities and physicians are dedicated to pharmacological stress testing with MRI and the future clinical impact of this promising technique will depend on its potential to provide information beyond myocardial function including perfusion, metabolism and coronary anatomy in form of a ''one-stop''-shop for the cardiac patient

  8. Electrocardiographic intricacies clarified by echocardiography--should the electrocardiogram be interpreted echocardiographically?

    Science.gov (United States)

    Ker, James

    2012-07-12

    During the past century the electrocardiogram (ECG) has established itself as an integral part of the cardiovascular examination. Since the first direct recordings of cardiac potentials by Waller in 1887, to the invention of the string galvanometer by Willem Einthoven in 1901, to use in the clinic by 1910, the electrocardiogram has become the most widely used clinical tool in the diagnosis of virtually every type of heart disease. Currently up to 20 million ECGs are performed annually in the United States alone. However, in this era of readily available echocardiography, an important caveat in the interpretation of the electrocardiogram has emerged: variants of intracardiac structures which might mimic disease on the ECG. In this perspective various structural variants of intracardiac structures, specifically variants of papillary muscles and subaortic muscular bands, will be shown, together with their associated electrocardiographic changes, mimicking disease. It is concluded that in this era of readily available echocardiography, the electrocardiogram should be interpreted echocardiographically in instances where intricate variations are seen on the surface electrocardiogram. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. T2 values of femoral cartilage of the knee joint: Comparison between pre-contrast and post-contrast images

    International Nuclear Information System (INIS)

    Yoon, Hyun Jung; Yoon, Young Cheol; Choe, Bong Keun

    2014-01-01

    To retrospectively evaluate the relationship between T2 values of pre- and post-contrast magnetic resonance (MR) images of femoral cartilage in patients with varying degrees of osteoarthritis. A total of 19 patients underwent delayed gadolinium-enhanced MRI of cartilage. Six regions of interest for T2 value measurement were obtained from pre- and post-contrast T2-weighted, sagittal, multi-slice, multi-echo, source images in each subject. Regions with modified Noyes classification grade 2B and 3 were excluded. Comparison of T2 values between pre- and post-contrast images and T2 values among regions with the grade 0, 1 and 2A groups were statistically analyzed. Of a total of 114 regions, 79 regions showing grade 0 (n = 46), 1 (n = 18), or 2A (n = 15) were analyzed. The overall and individual T2 values of post-contrast images were significantly lower than those of pre-contrast images (overall, 35.3 ± 9.2 [mean ± SD] vs. 29.9 ± 8.2, p < 0.01; range of individual, 28.9-37.6 vs. 27.1-36.4, p < 0.01). Pearson correlation coefficients showed a strong positive correlation between pre- and post-contrast images (rho-Pearson = 0.712-0.905). T2 values of pre- and post-contrast images of the grade 0 group were significantly lower than those of the grade 1/2A group (pre T2, p = 0.003; post T2, p = 0.006). T2 values of the femoral cartilage of the knee joint are significantly lower on post-contrast images than on pre-contrast images. Furthermore, these T2 values have a strong positive correlation between pre- and post-contrast images.

  10. T2 values of femoral cartilage of the knee joint: Comparison between pre-contrast and post-contrast images

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hyun Jung; Yoon, Young Cheol [Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Choe, Bong Keun [Department of Preventive Medicine, Kyung Hee University School of Medicine, Seoul (Korea, Republic of)

    2014-02-15

    To retrospectively evaluate the relationship between T2 values of pre- and post-contrast magnetic resonance (MR) images of femoral cartilage in patients with varying degrees of osteoarthritis. A total of 19 patients underwent delayed gadolinium-enhanced MRI of cartilage. Six regions of interest for T2 value measurement were obtained from pre- and post-contrast T2-weighted, sagittal, multi-slice, multi-echo, source images in each subject. Regions with modified Noyes classification grade 2B and 3 were excluded. Comparison of T2 values between pre- and post-contrast images and T2 values among regions with the grade 0, 1 and 2A groups were statistically analyzed. Of a total of 114 regions, 79 regions showing grade 0 (n = 46), 1 (n = 18), or 2A (n = 15) were analyzed. The overall and individual T2 values of post-contrast images were significantly lower than those of pre-contrast images (overall, 35.3 ± 9.2 [mean ± SD] vs. 29.9 ± 8.2, p < 0.01; range of individual, 28.9-37.6 vs. 27.1-36.4, p < 0.01). Pearson correlation coefficients showed a strong positive correlation between pre- and post-contrast images (rho-Pearson = 0.712-0.905). T2 values of pre- and post-contrast images of the grade 0 group were significantly lower than those of the grade 1/2A group (pre T2, p = 0.003; post T2, p = 0.006). T2 values of the femoral cartilage of the knee joint are significantly lower on post-contrast images than on pre-contrast images. Furthermore, these T2 values have a strong positive correlation between pre- and post-contrast images.

  11. Automated measurement and classification of pulmonary blood-flow velocity patterns using phase-contrast MRI and correlation analysis.

    Science.gov (United States)

    van Amerom, Joshua F P; Kellenberger, Christian J; Yoo, Shi-Joon; Macgowan, Christopher K

    2009-01-01

    An automated method was evaluated to detect blood flow in small pulmonary arteries and classify each as artery or vein, based on a temporal correlation analysis of their blood-flow velocity patterns. The method was evaluated using velocity-sensitive phase-contrast magnetic resonance data collected in vitro with a pulsatile flow phantom and in vivo in 11 human volunteers. The accuracy of the method was validated in vitro, which showed relative velocity errors of 12% at low spatial resolution (four voxels per diameter), but was reduced to 5% at increased spatial resolution (16 voxels per diameter). The performance of the method was evaluated in vivo according to its reproducibility and agreement with manual velocity measurements by an experienced radiologist. In all volunteers, the correlation analysis was able to detect and segment peripheral pulmonary vessels and distinguish arterial from venous velocity patterns. The intrasubject variability of repeated measurements was approximately 10% of peak velocity, or 2.8 cm/s root-mean-variance, demonstrating the high reproducibility of the method. Excellent agreement was obtained between the correlation analysis and radiologist measurements of pulmonary velocities, with a correlation of R2=0.98 (P<.001) and a slope of 0.99+/-0.01.

  12. Focus assessed transthoracic echocardiography (FATE) in patients acutely admitted with respiratory symptoms

    DEFF Research Database (Denmark)

    Laursen, Christian Borbjerg; Jakobsen, Carl-Johan; Lassen, Annmarie Touborg

    2012-01-01

    echocardiography for cardiopulmonary monitoring in intensive care. Eur J Anaesthesiol 2004; 21 (9): 700-7 2. Breitkreutz R, Walcher F, Seeger FH. Focus echocardiographic evaluation in resuscitation management: concept of an advanced life support- conformed algorithm. Crit Care Med 2007; 35 (5 Suppl): 150-61 3. Ray...

  13. Nuclear cardiology between echocardiography and coronary angiography in the management of CAD

    International Nuclear Information System (INIS)

    Anger, K.

    1996-01-01

    In managing coronary artery disease there are clearly posed questions: In diagnosis to assess presence, extent and severity of CAD, in therapy to assess prognosis and benefit of PTCA and ACVB. Coronary angiography remains the gold standard for assessing coronary stenosis, function imaging - stress echocardiography - and myocardial perfusion imaging (MIP) are assessing ischemia, i.e. extent and severity of CAD meaning prognosis and benefit of invasive therapy. The costs of echo /MPI/ catherization are 1 : 2: 6. When the essential conditions in non invasive investigations are observed - exact indication, maximal quality, evaluation of efficacy D, M and O - equal acceptance of all methods by cardiologists is attainable and there will be a great potential of cost saving in invasive diagnostics and therapy. The part of MPI is assessed in evaluating myocardium viability and benefit of invasive therapy, in the diagnosis of ischemia and evaluation of outcome MPI eventually will be replaced by stress echocardiography in future. (orig.) [de

  14. The expression of myocardial injury in cold induced myocardial imaging and echocardiography of systematic scleroderma

    International Nuclear Information System (INIS)

    Liang Jiugen; Zhu Xiaojun; Jiang Ningyi; Chen Shaoxiong

    1999-01-01

    The study was performed with cold-induced 99m Tc(MIBI) myocardial imaging (MI) in 23 patients with systematic scleroderma. The left ventricular function and wall motion were also observed by dimensional echocardiography (UCG). 14 patients had myocardial perfusion abnormalities visualized by MI, including 5 cases with fixed defects of 9 segments, 3 cases with reversible defects of 6 segments and 6 cases with both fixed and reversible one of 14 segments. The positive rate in myocardial imaging had no significant differences between patients with and without Raynaud's phenomenon (0.5>P>0.25). Compared with baseline, the ejection fraction, stroke volume, cardiac output were significantly decreased during cold-induced in patients with abnormal myocardial scintigraphy (P<0.05), and had significant difference compared with normal group (P<0.05). 4 cases with cold-induced reversible perfusion defects had anatomically correlated regional ventricular hypokinesia in UCG

  15. A rare localization in right-sided endocarditis diagnosed by echocardiography: A case report

    Directory of Open Access Journals (Sweden)

    Beaufils Philippe

    2003-08-01

    Full Text Available Abstract Background Right-sided endocarditis occurs predominantly in intravenous drug users, patients with pacemakers or central venous lines and with congenital heart diseases. The vast majority of cases involve the tricuspid valve. Case presentation A case of a 31-year-old woman with intravenous drug abuse who had a right-sided vegetation attached to the muscular bundle of the right ventricle is presented. Transthoracic echocardiography revealed a vegetation in the right ventricular outflow tract. Transesophageal echocardiography clearly showed that the 1.8 cm vegetation was not adherent to the pulmonary valve but attached to a muscular bundle. Conclusions Our case points to an unusual location of right-sided endocarditis in intravenous drug users. It confirms that TTE remains an easy and highly sensitive first-line examination for the diagnosis of right-sided endocarditis.

  16. Addison's disease due to adrenal tuberculosis: Contrast-enhanced CT features and clinical duration correlation

    International Nuclear Information System (INIS)

    Guo Yingkun; Yang Zhigang; Li Yuan; Ma Ensen; Deng Yuping; Min Pengqiu; Yin Longlin; Hu Jian; Zhang Xiaochun; Chen Tianwu

    2007-01-01

    Purpose: To describe CT morphology of untreated adrenal tuberculosis during the different stages of the natural history of the disease and to evaluate the diagnostic implications of CT features. Materials and methods: We retrospectively evaluated CT features in 42 patients with documented adrenal tuberculosis for the location, size, morphology, and enhancement patterns shown on CT images. The clinical duration were correlated with the CT features. Results: Of the 42 patients with untreated adrenal tuberculosis, bilaterally enlarged adrenal glands were revealed in 38 cases (91%), unilaterally enlarged in 3 cases (7%), and normal size in 1 case (2%). Of the 41 cases (98%) with enlargement, mass-like enlargement was seen in 20 cases (49%) and enlargement with preserved contours in 21 cases (51%). Peripheral rim enhancement presented in 22 cases (52%) on contrast-enhanced CT. Non-enhanced CT scan revealed calcification in 21 cases (50%). As the duration of Addison's disease increased, the presence of calcification and contour preservation increased concomitantly (p < 0.001), whereas peripheral rim enhancement and mass-like enlargement decreased concomitantly on CT images (p < 0.001). Conclusion: CT may be helpful in diagnosing adrenal tuberculosis when clinically suspected, and CT features are correlated to the clinical duration of Addison's disease

  17. The effect of transesophageal echocardiography in the surgical treatment of tetralogy of Fallot.

    Science.gov (United States)

    Wang, L-C; Li, S-K; Zhu, F-T; Bian, T; Wang, H-Y

    2018-04-01

    To investigate the effect of transesophageal echocardiography (TEE) in the surgical treatment of tetralogy of Fallot. 98 patients with tetralogy of Fallot received and cured by Zhengzhou Cardiovascular Hospital (Zhengzhou No. 7 People's Hospital) from January 2015 to January 2017 were selected as the study objects. All patients were examined by TEE before surgery, and the pulmonary artery index (PAI) and pulmonary vein index (PVI) were measured, so as to analyze the effect of TEE in the surgical treatment of tetralogy of Fallot. Among the 98 patients, 12 patients were diagnosed with intensive care unit (ICU) retention, 23 patients were diagnosed with respirator assisted respiration extension, 8 patients were diagnosed with low cardiac output syndrome, and 10 patients were diagnosed with respiratory tract infection, which indicated that TEE could diagnose conditions after radical operation of tetralogy of Fallot. The calculation results showed that the PAI was (171.37±58.39) mm2/m2 and the PVI was (282.46±54.37) mm2/m2. The Pearson correlation analysis showed that the correlation between them was good (r=0.821, ptetralogy of Fallot. TEE can predict the occurrence of respirator assisted respiration extension, ICU retention and low cardiac output syndrome of patients after radical surgery by evaluating the PAI and PVI of patients with tetralogy of Fallot.

  18. Combined evaluation of rest-redistribution thallium-201 tomography and low-dose dobutamine echocardiography enhances the identification of viable myocardium in patients with chronic coronary artery disease

    International Nuclear Information System (INIS)

    Pace, L.; Cuocolo, A.; Salvatore, M.; Perrone-Filardi, P.; Prastaro, M.; Vezzuto, P.; Crisci, T.; Dellegrottaglie, S.; Piscione, F.; Chiariello, M.; Mainenti, P.P.; Varrone, A.

    1998-01-01

    The purpose of this study was to evaluate whether combined evaluation by discriminant analysis of rest-redistribution thallium-201 tomography and low-dose dobutamine echocardiography enhances the accuracy in identifying viable myocardium in patients with chronic coronary artery disease. Rest-redistribution 201 Tl has high sensitivity but low specificity in identifying viable myocardium, while the opposite is true for low-dose dobutamine echocardiography. Forty-six patients underwent low-dose dobutamine echocardiography and rest-redistribution 201 Tl tomography on the same day. Rest echocardiography was repeated at least 30 days (mean 40±20) after myocardial revascularization. Discriminant analysis was applied to the results of 201 Tl tomography and dobutamine echocardiography to classify a/dyskinetic segments as viable or non-viable. In 92 a/dyskinetic segments that were revascularized, rest-redistribution 201 Tl tomography yielded an accuracy of 75%, while the accuracy of dobutamine echocardiography was 70% (P 201 Tl imaging are useful and complementary techniques for identifying viable myocardium in patients with chronic coronary artery disease. Combined evaluation by discriminant analysis significantly improves accuracy, although the cost-effectiveness of such an approach remains to be determined. (orig.)

  19. Intraventricular dyssynchrony in light chain amyloidosis: a new mechanism of systolic dysfunction assessed by 3-dimensional echocardiography

    Directory of Open Access Journals (Sweden)

    Truran Seth

    2008-08-01

    Full Text Available Abstract Background Light chain amyloidosis (AL is a rare but often fatal disease due to intractable heart failure. Amyloid deposition leads to diastolic dysfunction and often preserved ejection fraction. We hypothesize that AL is associated with regional systolic dyssynchrony. The aim is to compare left ventricular (LV regional synchrony in AL subjects versus healthy controls using 16-segment dyssynchrony index measured from 3-dimension-al (3D echocardiography. Methods Cardiac 3D echocardiography full volumes were acquired in 10 biopsy-proven AL subjects (60 ± 3 years, 5 females and 10 healthy controls (52 ± 1 years, 5 females. The LV was subdivided into 16 segments and the time from end-diastole to the minimal systolic volume for each of the 16 segments was expressed as a percent of the cycle length. The standard deviations of these times provided a 16-segment dyssynchrony index (16-SD%. 16-SD% was compared between healthy and AL subjects. Results Left ventricular ejection fraction was comparable (control vs. AL: 62.4 ± 0.6 vs. 58.6 ± 2.8%, p = NS. 16-SD% was significantly higher in AL versus healthy subjects (5.93 ± 4.4 vs. 1.67 ± 0.87%, p = 0.003. 16-SD% correlated with left ventricular mass index (R 0.45, p = 0.04 but not to left ventricular ejection fraction. Conclusion Light chain amyloidosis is associated with left ventricular regional systolic dyssynchrony. Regional dyssynchrony may be an unrecognized mechanism of heart failure in AL subjects.

  20. Correlation between ICDAS and histology: Differences between stereomicroscopy and microradiography with contrast solution as histological techniques.

    Directory of Open Access Journals (Sweden)

    Samara de Azevedo Gomes Campos

    Full Text Available Detection of occlusal caries with visual examination using ICDAS correlates strongly with histology under stereomicroscopy (SM, but dentin aspects under SM are ambiguous regarding mineral content. Thus, our aim was to test two null hypotheses: SM and microradiography result in similar correlations between ICDAS and histology; SM and microradiography result in similar positive (PPV and negative predictive values (NPV of ICDAS cut-off 1-2 (scores 0-2 as sound with histological threshold D3 (demineralization in the inner third of dentin. Occlusal surfaces of extracted permanent teeth (n = 115 were scored using ICDAS. Undemineralized ground sections were histologically scored using both SM without contrast solution and microradiography after immersion in Thoulet's solution 1.47 for 24 h (MRC. Correlation between ICDAS and histology differed from SM (0.782 to MRC (0.511 (p = 0.0002, with a large effect size "q" of 0.49 (95% CI: 0.638/0.338. For ICDAS cut-off 1-2 and D3, PPV from MRC (0.56 was higher than that from SM (0.28 (p< 0.00001; effect size h = 0.81, and NPV from MRC (0.72 was lower than that from SM (1,00 (p < 0.00001; effect size h = 1.58. In conclusion, SM overestimated the correlation between ICDAS and lesion depth, and underestimated the number of occlusal surfaces with ICDAS cut-off 1-2 and deep dentin demineralization.

  1. Serial change of 123I-BMIPP SPECT imaging during recovery from stunned myocardium after acute myocardial infarction. Correlation with 201Tl and two-dimensional echocardiography

    International Nuclear Information System (INIS)

    Nakano, Akira; Kondo, Makoto; Tokunaga, Satoshi; Akiyama, Kiyozumi; Mori, Yoshihisa; Nosue, Yasuhiro; Makita, Toshinori; Tanio, Hitoshi; Shimono, Yukio

    1995-01-01

    Using 123 I-β-methyl iodophenyl pentadecanoic acid ( 123 I-BMIPP), we investigated changes in myocardial fatty acid metabolism at recovery from stunned myocardium after acute myocardial infarction (AMI), correlation with recovery of regional wall motion and thallium-201 ( 201 Tl) distribution in particular. The subjects were 15 patients who underwent successful reperfusion therapy after the first onset of AMI. None of the patients had multi-vessel disease or ischemic episode during their clinical course. Patients underwent 123 I-BMIPP scintigraphy, 201 Tl scintigraphy and two-dimensional echocardiography during the acute and chronic phases. Then, we compared regional wall motion with distribution of 123 I-BMIPP and 201 Tl. Regional wall motion and SPECT were evaluated by the established 16 segment model. In patients, showing serial improvement in regional wall motion, there was 80.0% (8/10) showed normal 201 Tl distribution during the acute phase or normalized during the chronic phase. However, distribution of 123 I-BMIPP normalized only in 10.0% (1/10) of this group. In examination of each segment that showed serial improvement in regional wall motion, 92.3% (24/26) of these segments showed normal distribution of 201 Tl during the acute phase or normalized distribution during chronic phase, despite distribution of 123 I-BMIPP improved in only 3.8% (1/26) of these segments. These indicate that, in the process of recovery from myocardial stunning after AMI, abnormal distribution of 123 I-BMIPP continued longer than abnormal distribution of 201 Tl. (author)

  2. Multi-parametric quantification of tricuspid regurgitation using cardiovascular magnetic resonance: A comparison to echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Medvedofsky, Diego [Department of Medicine, University of Chicago Medical Center, Chicago, IL (United States); Jimenez, Javier Leon [Complejo Hospitalario Universitario de Huelva, Huelva (Spain); Addetia, Karima; Singh, Amita; Lang, Roberto M. [Department of Medicine, University of Chicago Medical Center, Chicago, IL (United States); Mor-Avi, Victor, E-mail: vmoravi@bsd.uchicago.edu [Department of Medicine, University of Chicago Medical Center, Chicago, IL (United States); Patel, Amit R. [Department of Medicine, University of Chicago Medical Center, Chicago, IL (United States)

    2017-01-15

    Background: Velocity-encoding is used to quantify tricuspid regurgitation (TR) by cardiovascular magnetic resonance (CMR), but requires additional dedicated imaging. We hypothesized that size and signal intensity (SI) of the cross-sectional TR jet area in the right atrium in short-axis steady-state free-precession images could be used to assess TR severity. Methods: We studied 61 patients with TR, who underwent CMR and echocardiography within 24 h. TR severity was determined by vena contracta: severe (N = 20), moderate or mild (N = 41). CMR TR jet area and normalized SI were measured in the plane and frame that depicted maximum area. ROC analysis was performed in 21/61 patients to determine diagnostic accuracy of differentiating degrees of TR. Optimal cutoffs were independently tested in the remaining 40 patients. Results: Measurable regions of signal loss depicting TR jets were noted in 51/61 patients, while 9/10 remaining patients had mild TR by echocardiography. With increasing TR severity, jet area significantly increased (15 ± 14 to 38 ± 20 mm{sup 2}), while normalized SI decreased (57 ± 27 to 23 ± 11). ROC analysis showed high AUC values in the derivation group and good accuracy in the test group. Conclusion: TR can be quantified from short-axis CMR images in agreement with echocardiography, while circumventing additional image acquisition.

  3. The use of TEE simulation in teaching basic echocardiography skills to senior anesthesiology residents.

    Science.gov (United States)

    Jelacic, Srdjan; Bowdle, Andrew; Togashi, Kei; VonHomeyer, Peter

    2013-08-01

    The authors evaluated the educational benefits of using a first-generation HeartWorks simulator to teach senior anesthesiology residents basic echocardiography skills. Prospective observational study. A single academic medical center (teaching hospital). Thirty-seven senior (fourth-year) anesthesiology residents participated in this study. Groups of 3 senior anesthesiology residents participated in a single 3-hour tutorial in the simulation laboratory in the authors' institution during their cardiothoracic anesthesiology rotation. A cardiothoracic anesthesiology faculty member demonstrated the use of the transesophageal echocardiography (TEE) simulator and instructed the residents on obtaining standard TEE views of normal anatomy. Prior to the laboratory session, the residents took an online multiple-choice pretest with 25 questions related to safety, probe manipulation, clinical application, and pathology, which was accompanied by echo images of normal cardiac anatomy and video clips of pathology. Three to four weeks after the TEE tutorial, the residents completed an online post-test and evaluation of the teaching session. There was a statistically significant increase in knowledge of normal echocardiographic anatomy (p = 0.04), with an average improvement in normal echocardiographic anatomy scores of 15%. Virtual reality TEE simulation technology was endorsed strongly by residents, produced a statistically significant improvement in knowledge of normal echocardiographic anatomy, and could be effective for teaching basic echocardiography to anesthesiology residents. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Three- and four-dimensional ultrasound in fetal echocardiography: an up-to-date overview

    NARCIS (Netherlands)

    Adriaanse, B.M.; Vugt, J.M.G. van; Haak, M.C.

    2016-01-01

    Congenital heart diseases (CHD) are the most commonly overlooked lesions in prenatal screening programs. Real-time two-dimensional ultrasound (2DUS) is the conventionally used tool for fetal echocardiography. Although continuous improvements in the hardware and post-processing software have resulted

  5. Three-dimensional transesophageal echocardiography in the evaluation of aortic valve destruction by endocarditis

    NARCIS (Netherlands)

    Nemes, Attila; Lagrand, Wim K.; McGhie, Jackie S.; ten Cate, Folkert J.

    2006-01-01

    Infective endocarditis remains a serious and complex disease with significant morbidity and mortality. The aim of this study was to demonstrate the clinical usefulness of 3-dimensional transesophageal echocardiography for the spatial assessment of aortic valve endocarditis. This case showed severe

  6. Relevance of tissue Doppler in the quantification of stress echocardiography for the detection of myocardial ischemia in clinical practice

    Directory of Open Access Journals (Sweden)

    Sicari Rosa

    2005-01-01

    Full Text Available Abstract In the present article we review the main published data on the application of Tissue Doppler Imaging (TDI to stress echocardiography for the detection of myocardial ischemia. TDI has been applied to stress echocardiography in order to overcome the limitations of visual analysis for myocardial ischemia. The introduction of a new technology for clinical routine use should pass through the different phases of scientific assessment from feasibility studies to large multicenter studies, from efficacy to effectiveness studies. Nonetheless the pro-technology bias plays a major role in medicine and expensive and sophisticated techniques are accepted before their real usefulness and incremental value to the available ones is assessed. Apparently, TDI is not exempted by this approach : its applications are not substantiated by strong and sound results. Nonetheless, conventional stress echocardiography for myocardial ischemia detection is heavily criticized on the basis of its subjectivity. Stress echocardiography has a long lasting history and the evidence collected over 20 years positioned it as an established tool for the detection and prognostication of coronary artery disease. The quantitative assessment of myocardial ischemia remains a scientific challenge and a clinical goal but time has not come for these newer ultrasonographic techniques which should be restricted to research laboratories.

  7. What is the most cost-effective strategy to screen for left ventricular systolic dysfunction: natriuretic peptides, the electrocardiogram, hand-held echocardiography, traditional echocardiography, or their combination?

    Science.gov (United States)

    Galasko, Gavin I W; Barnes, Sophie C; Collinson, Paul; Lahiri, Avijit; Senior, Roxy

    2006-01-01

    To assess the screening characteristics and cost-effectiveness of screening for left ventricular systolic dysfunction (LVSD) in community subjects. A total of 1392 members of the general public and 928 higher risk subjects were randomly selected from seven community practices. Attending subjects underwent an ECG, N-terminal pro-brain natriuretic peptide (NTproBNP) serum levels, and traditional echocardiography (TE). A total of 533 consecutive subjects underwent hand-held echocardiography (HE). The screening characteristics and cost-effectiveness (cost per case of LVSD diagnosed) of eight strategies to predict LVSD (LVSD cost-effective, screening low-risk subjects least cost-effective. TE screening was the least cost-effective strategy. NTproBNP screening gave similar cost savings to ECG screening; HE screening greater cost-savings, and HE screening following NTproBNP or ECG pre-screening the greatest cost-savings, costing approximately 650 Euros per case of LVSD diagnosed in high-risk subjects (63% cost-savings vs.TE). Thus several different modalities allow cost-effective community-based screening for LVSD, especially in high-risk subjects. Such programmes would be cost-effective and miss few cases of LVSD in the community.

  8. Evaluation of echocardiography and cardiac biomarker concentrations in dogs with gastric dilatation volvulus.

    Science.gov (United States)

    Aona, Brent D; Rush, John E; Rozanski, Elizabeth A; Cunningham, Suzanne M; Sharp, Claire R; Freeman, Lisa M

    2017-11-01

    To assess abnormalities in concentrations of cardiac troponin I (cTnI), lactate, and N-terminal pro-B-type natriuretic peptide (NT-proBNP) in relation to arrhythmias, echocardiographic measurements, and survival in dogs with gastric dilatation volvulus (GDV). Prospective observational study. University hospital. Twenty-two dogs with naturally occurring GDV. Concentrations of cTnI, plasma lactate, and NT-proBNP were recorded at presentation to the emergency room, the time closest to echocardiography, and the highest recorded concentrations during hospitalization. None. Cardiac rhythms were categorized on a 0-4 scale (0 = no ventricular premature complexes [VPCs], 1 = single VPCs, 2 = bigeminy or trigeminy, 3 = couplets or triplets, and 4 = R-on-T phenomenon or ventricular tachycardia). Echocardiography was performed 6-18 hours postoperatively. Fifteen dogs had ventricular arrhythmias during hospitalization (Grade 1 [n = 9], Grade 4 [n = 6]). The highest recorded cTnI concentration was significantly higher in the dogs with Grade 4 (P = 0.002) or Grade 1 (P = 0.001) arrhythmias compared to dogs without arrhythmias. Plasma lactate was significantly correlated with left ventricular internal diameter in diastole (r = -0.52, P = 0.01) and systole (r = -0.57, P = 0.006), left ventricular free wall in diastole (LWDd, r = 0.59, P = 0.004), and interventricular septal thickness in diastole (IVDs, r = 0.65, P = 0.001). Dogs that did not survive to 1 week postdischarge (3/22) had a significantly thicker LVWd (P = 0.04) and IVSd (P = 0.05), and received significantly less fluids in the first 24 (P = 0.02) and 48 hours (P = 0.03) of hospitalization. Concentrations of cTnI and NT-proBNP increased during hospitalization, but only cTnI concentrations were significantly higher in dogs with a higher arrhythmia grade. Additional research on the potential role of serial measurement of biomarkers in dogs with GDV is warranted. © Veterinary Emergency and Critical Care Society 2017.

  9. Cardiac output by Doppler echocardiography in the premature baboon: Comparison with radiolabeled microspheres

    International Nuclear Information System (INIS)

    Kinsella, J.P.; Morrow, W.R.; Gerstmann, D.R.; Taylor, A.F.; deLemos, R.A.

    1991-01-01

    Pulsed-Doppler echocardiography (PDE) is a useful noninvasive method for determining left ventricular output (LVO). However, despite increasingly widespread use in neonatal intensive care units, validation studies in prematures with cardiopulmonary disease are lacking. The purpose of this study was to compare radiolabeled microsphere (RLM) and PDE measurements of LVO, using the critically ill premature baboon as a model of the human neonate. Twenty-two paired RLM and PDE measurements of LVO were obtained in 14 animals between 3 and 24 h of age. Average PDE LVO was 152 ml/min/kg (range, 40-258 ml/min/kg) compared to 158 ml/min/kg (range, 67-278 ml/min/kg) measured by RLM. Linear regression analysis of the paired measurements showed good correlation with a slope near unity (gamma = 0.94x + 4.20, r = 0.91, SEE = 25.7 ml). The authors conclude that PDE determinations of LVO compare well with those measured by RLM in the premature baboon. PDE appears to provide a valid estimate of LVO and should be useful in human prematures with cardiopulmonary distress

  10. OPPORTUNITIES OF TRANSVAGINAL ECHOCARDIOGRAPHY FOR EARLY PRENATAL DIAGNOSIS OF INBORN HEART DISEASES IN FETUS

    Directory of Open Access Journals (Sweden)

    E.A. Shevchenko

    2008-01-01

    Full Text Available According to the literature data, transvaginal echocardiography (Echocg is the method, used for the doppler diagnostics in early terms of pregnancy (if principles of safety are observed. This method allows detecting about 70–97% of all prognostic cally significant inborn heart diseases in fetus, beginning at 12 week of pregnancy. a scheme of research includes estimation of four chamber cut of fetus heart, and study of state of its main arteries. This is an expert investigation, because it needs special grounding of specialist, high resolution ultrasonic equipment, and considerable expense of time. Wile parameters are estimated, it is necessary to use normative rates of sizes of ventricles and main arteries of fetus, developed by Russian experts, taking into account individual variations.Key words: transvaginal echocardiography, diagnosis, inborn heart disease.

  11. Dobutamine stress thallium-201 single-photon emission tomography versus echocardiography for evaluation of the extent and location of coronary artery disease late after myocardial infarction

    International Nuclear Information System (INIS)

    Elhendy, A.; Bax, J.J.; Domburg, R.T. van; Cornel, J.H.; Roelandt, J.R.T.C.; Valkema, R.; Reijs, A.E.M.; Krenning, E.P.

    1999-01-01

    Dobutamine stress echocardiography and thallium-201 myocardial perfusion scintigraphy are clinically useful methods for the evaluation of coronary artery disease (CAD). However, the relative merits of these imaging modalities in the evaluation of the extent of CAD after myocardial infarction have not been well studied. The aim of this study was to compare the accuracy of dobutamine stress echocardiography and simultaneous 201 Tl single-photon emission tomography (SPET) imaging for the diagnosis and localization of CAD late after acute myocardial infarction. Dobutamine (up to 40 μg kg -1 min -1 )-atropine (up to 1 mg) stress echocardiography in conjunction with stress-reinjection 201 Tl SPET was performed for the evaluation of myocardial ischaemia in 90 patients with previous myocardial infarction who underwent coronary angiography. Significant CAD was predicted on bases of myocardial ischemia (new or worsening wall motion abnormalities on echocardiography and reversible perfusion defects on 201 Tl SPET). Significant CAD (≥ 50% luminal diameter stenosis) was detected in 73 (81%) patients. The sensitivity, specificity and accuracy of echocardiography in detecting remote ischaemia for the diagnosis of remote CAD (present in 53 patients) were, respectively, 79% (CI 70%-88%), 85% (CI 77%-93%) and 81% (CI 73%-90%), while the corresponding figures for 201 Tl SPET were 75% (CI 66%-85%), 78% (CI 69%-87%) and 76% (CI 67%-86%) respectively (P = NS vs echocardiography). The sensitivity, specificity and accuracy of echocardiography in detecting peri-infarction ischaemia for the diagnosis of infarct-related artery stenosis (present in 70 patients) were, rspectively, 77% (CI 68%-86%), 85% (CI 78%-92%) and 79% (CI 70%-87%) while the corresponding figures for 201 Tl SPET were 73% (CI 64%-82%), 85% (CI 78%-92%) and 76% (CI 67%-84%) respectively (P = NS vs echocardiography). The agreement between the two methods for the diagnosis of peri-infarction and remote ischaemia was 70

  12. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy.

    Science.gov (United States)

    Khan, Sitara G; Klettas, Dimitris; Kapetanakis, Stam; Monaghan, Mark J

    2016-03-01

    Cardiac resynchronisation therapy (CRT) can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain) has conventionally been assessed using tissue Doppler imaging (TDI), which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference ('speckles') in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT. © 2016 The authors.

  13. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy

    Directory of Open Access Journals (Sweden)

    Sitara G Khan

    2016-05-01

    Full Text Available Cardiac resynchronisation therapy (CRT can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain has conventionally been assessed using tissue Doppler imaging (TDI, which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference (‘speckles’ in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT.

  14. Radiotherapy-induced Early ECG Changes and Their Comparison with Echocardiography in Patients with Early-stage Breast Cancer.

    Science.gov (United States)

    Tuohinen, Suvi Sirkku; Keski-Pukkila, Konsta; Skyttä, Tanja; Huhtala, Heini; Virtanen, Vesa; Kellokumpu-Lehtinen, Pirkko-Liisa; Raatikainen, Pekka; Nikus, Kjell

    2018-04-01

    Early electrocardiogram (ECG) changes after breast cancer radiotherapy (RT) have been reported, but their characteristics and associated factors are largely unknown. This study aimed to explore early RT-induced ECG changes and to compare them with echocardiography changes. Sixty eligible patients with chemotherapy-naïve left-sided and 20 with right-sided breast cancer were evaluated with echocardiography, blood samples and ECG before and after RT. RT-induced ECG changes in the anterior leads. T-Wave changes were most frequent. T-Wave decline was associated independently with patient age (β=-0.245, p=0.005), mean heart radiation dose (β=1.252, p=0.001) and global systolic strain rate change (β=7.943, p=0.002). T-Wave inversion was associated independently with mean heart radiation dose (β=0.143, pECG changes were prevalent and associated with functional and structural changes in echocardiography. ECG could be used for post-RT cardiac screening. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  15. Evaluation of cerebral-cardiac syndrome using echocardiography in a canine model of acute traumatic brain injury.

    Science.gov (United States)

    Qian, Rong; Yang, Weizhong; Wang, Xiumei; Xu, Zhen; Liu, Xiaodong; Sun, Bing

    2015-01-01

    Previous studies have confirmed that traumatic brain injury (TBI) can induce general adaptation syndrome (GAS), which subsequently results in myocardial dysfunction and damage in some patients with acute TBI; this condition is also termed as cerebral-cardiac syndrome. However, most clinicians ignore the detection and treatment of myocardial dysfunction, and instead concentrate only on the serious neural damage that is observed in acute TBI, which is one of the most important fatal factors. Therefore, clarification is urgently needed regarding the relationship between TBI and myocardial dysfunction. In the present study, we evaluated 18 canine models of acute TBI, by using real-time myocardial contrast echocardiography and strain rate imaging to accurately evaluate myocardial function and regional microcirculation, including the strain rate of the different myocardial segments, time-amplitude curves, mean ascending slope of the curve, and local myocardial blood flow. Our results suggest that acute TBI often results in cerebral-cardiac syndrome, which rapidly progresses to the serious stage within 3 days. This study is the first to provide comprehensive ultrasonic characteristics of cerebral-cardiac syndrome in an animal model of TBI.

  16. Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants. Comparison with transthoracic echocardiography

    International Nuclear Information System (INIS)

    Goo, Hyun Woo

    2018-01-01

    Considering inherent limitations of transthoracic echocardiography, the diagnostic accuracy of cardiac CT in identifying coronary artery anatomy before arterial switch operation needs to be investigated with recently improved coronary artery visibility using electrocardiogram (ECG)-synchronized dual-source CT. To compare diagnostic accuracy between cardiac CT using a dual-source scanner and transthoracic echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. The study included 101 infants (median age 4 days, range 0 days to 10 months; M:F=78:23) who underwent ECG-synchronized cardiac dual-source CT and transthoracic echocardiography before arterial switch operation between July 2011 and December 2016. We evaluated and classified coronary artery anatomy on cardiac CT and transthoracic echocardiography. With the surgical findings as the reference standard, we compared the diagnostic accuracy for identifying coronary artery anatomy between cardiac CT and transthoracic echocardiography. The most common coronary artery pattern was the usual pattern (left coronary artery from sinus 1 and right coronary artery from sinus 2; 64.4%, 65/101), followed by a single coronary artery from sinus 2 and a conal branch from sinus 1 (7.9%, 8/101), the inverted pattern (5.9%, 6/101), the right coronary artery and left anterior descending artery from sinus 1 and the left circumflex artery from sinus 2 (5.9%, 6/101), and others. In 96 infants with surgically proven coronary artery anatomy, the diagnostic accuracy of cardiac CT was significantly higher than that of transthoracic echocardiography (91.7%, 88/96 vs. 54.2%, 52/96; P<0.0001). Diagnostic accuracy of cardiac CT is significantly higher than that of echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. (orig.)

  17. Identification of coronary artery anatomy on dual-source cardiac computed tomography before arterial switch operation in newborns and young infants. Comparison with transthoracic echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Goo, Hyun Woo [University of Ulsan College of Medicine, Asan Medical Center, Department of Radiology and Research Institute of Radiology, Seoul (Korea, Republic of)

    2018-02-15

    Considering inherent limitations of transthoracic echocardiography, the diagnostic accuracy of cardiac CT in identifying coronary artery anatomy before arterial switch operation needs to be investigated with recently improved coronary artery visibility using electrocardiogram (ECG)-synchronized dual-source CT. To compare diagnostic accuracy between cardiac CT using a dual-source scanner and transthoracic echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. The study included 101 infants (median age 4 days, range 0 days to 10 months; M:F=78:23) who underwent ECG-synchronized cardiac dual-source CT and transthoracic echocardiography before arterial switch operation between July 2011 and December 2016. We evaluated and classified coronary artery anatomy on cardiac CT and transthoracic echocardiography. With the surgical findings as the reference standard, we compared the diagnostic accuracy for identifying coronary artery anatomy between cardiac CT and transthoracic echocardiography. The most common coronary artery pattern was the usual pattern (left coronary artery from sinus 1 and right coronary artery from sinus 2; 64.4%, 65/101), followed by a single coronary artery from sinus 2 and a conal branch from sinus 1 (7.9%, 8/101), the inverted pattern (5.9%, 6/101), the right coronary artery and left anterior descending artery from sinus 1 and the left circumflex artery from sinus 2 (5.9%, 6/101), and others. In 96 infants with surgically proven coronary artery anatomy, the diagnostic accuracy of cardiac CT was significantly higher than that of transthoracic echocardiography (91.7%, 88/96 vs. 54.2%, 52/96; P<0.0001). Diagnostic accuracy of cardiac CT is significantly higher than that of echocardiography in identifying coronary artery anatomy before arterial switch operation in newborns and young infants. (orig.)

  18. Kawasaki disease-associated coronary artery lesions with navigator echo-based. Respiratory-gated three dimensional coronary magnetic resonance angiography compared with echocardiography in young children

    International Nuclear Information System (INIS)

    Amino, Masayuki; Teraoka, Kunihiko; Hirano, Masaharu; Kawashima, Naoshi; Kakizaki, Dai; Ookubo, Yasuo; Sasaki, Kazuyoshi; Katuyama, Hiroaki

    2004-01-01

    Navigator echo-based respiratory-gated three dimensional coronary magnetic resonance angiography (3D-CMRA) was compared with echocardiography, to determine whether 3D-CMRA was useful for the evaluation of Kawasaki disease-associated coronary artery lesions. Sixteen consecutive patients (imaging was performed 17 times in total) who were given a diagnosis of Kawasaki's disease at the pediatric department of our hospital and examined for the precise examination of complicating coronary artery lesions on MRI using a navigator-echo technique because of their incapability of holding their breath during imaging were entered into the present study. A 1.5T MRI system was used. Gd-DOTA was given at a total volume of 0.1 mmol/kg. During imaging, CMRA visualized the left coronary arteries in all 17 cases and the right coronary arteries in 16 cases, but not in one case. The left main coronary trunk segment no.5 was demonstrated in all cases with CMRA, but not in 4 cases with echocardiography. The left anterior descending branch no.6 was visualized in 11 of the 17 cases with CMRA, but only in 5 cases with echocardiography. The left circumflex branch no.11 was observed in 6 cases with CMRA, but only in 2 cases with echocardiography. As for the right coronary arteries, branches no.1 and no.2 were observed in 16 and 9 cases with CMRA, respectively, and in 13 and 3 cases with echocardiography, respectively. Vascular diameters measured on CMRA were almost identical to those on echocardiography, within the range of arteries visualized. 3D-CMRA combined with a navigator echo technique appears to be a useful tool for the observation of coronary artery lesions associated with Kawasaki's disease because it is superior in lesion visualization to echocardiography. (author)

  19. Dynamic contrast-enhanced MR imaging of the rectum: Correlations between single-section and whole-tumor histogram analyses.

    Science.gov (United States)

    Choi, M H; Oh, S N; Park, G E; Yeo, D-M; Jung, S E

    2018-05-10

    To evaluate the interobserver and intermethod correlations of histogram metrics of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) parameters acquired by multiple readers using the single-section and whole-tumor volume methods. Four DCE parameters (K trans , K ep , V e , V p ) were evaluated in 45 patients (31 men and 14 women; mean age, 61±11 years [range, 29-83 years]) with locally advanced rectal cancer using pre-chemoradiotherapy (CRT) MRI. Ten histogram metrics were extracted using two methods of lesion selection performed by three radiologists: the whole-tumor volume method for the whole tumor on axial section-by-section images and the single-section method for the entire area of the tumor on one axial image. The interobserver and intermethod correlations were evaluated using the intraclass correlation coefficients (ICCs). The ICCs showed excellent interobserver and intermethod correlations in most of histogram metrics of the DCE parameters. The ICCs among the three readers were > 0.7 (Phistogram metrics, except for the minimum and maximum. The intermethod correlations for most of the histogram metrics were excellent for each radiologist, regardless of the differences in the radiologists' experience. The interobserver and intermethod correlations for most of the histogram metrics of the DCE parameters are excellent in rectal cancer. Therefore, the single-section method may be a potential alternative to the whole-tumor volume method using pre-CRT MRI, despite the fact that the high agreement between the two methods cannot be extrapolated to post-CRT MRI. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  20. Atlas-based mosaicing of 3D transesophageal echocardiography images of the left atrium

    NARCIS (Netherlands)

    Mulder, H.W. (Harriët); Pluim, J.P.W.; Ren, B. (Ben); Haak, A. (Alexander); Viergever, M.A. (Max); Bosch, J.G. (Johan); Stralen, van M. (Marijn)

    2015-01-01

    3D transesophageal echocardiography (TEE) is routinely used for planning and guidance of cardiac interventions. However, the limited field-of-view dictates the compounding of multiple images for visualization of large structures, e.g. the left atrium (LA). Previously, we developed a TEE image

  1. Quantification of pulmonary regurgitation and prediction of pulmonary valve replacement by echocardiography in patients with congenital heart defects in comparison to cardiac magnetic resonance imaging.

    Science.gov (United States)

    Dellas, Claudia; Kammerer, Laura; Gravenhorst, Verena; Lotz, Joachim; Paul, Thomas; Steinmetz, Michael

    2018-04-01

    Pulmonary regurgitation (PR) is common in patients with congenital heart defects (CHD) and contributes to morbidity and mortality in the long-term. We investigated in this retrospective analysis whether readily accessible echocardiographic parameters are useful for quantification of PR and for predicting pulmonary valve replacement (PVR) in comparison to the gold-standard phase contrast (PC) flow measurements from cardiovascular magnetic resonance (CMR). Continuous wave (CW) Doppler and colour flow images in echocardiograms from 53 patients with CHD were analysed. Slope and jet-to-RVOT ratio correlated significantly with CMR-assessed regurgitation fraction (RF), whereas pressure half time (PHT) showed an inverse correlation. Patients with mild PR in CMR had significantly higher PHT, lower slope and jet-to-RVOT ratio than patients with moderate or severe regurgitation. The AUC regarding PR severity was 0.778 for PHT (95% CI, 0.649-0.907; P = 0.007 for CMR-RF ≤ 35%), 0.744 for slope (95% CI, 0.603-0.885; P = 0.017 for CMR-RF > 35%) and 0.652 for jet-to-RVOT ratio (95% CI, 0.473-0.860; P = 0.168 for CMR-RF > 35%). The optimal cut-off values calculated from ROC analysis were 95 ms for PHT and 4.9 m/s 2 for slope. In logistic regression analysis, slope emerged as the most valuable parameter for predicting the indication for PVR (OR 12.9, 95% CI, 1.8-90.9, P = 0.010). In conclusion, echocardiographic assessment of PR was feasible. Both parameters, PHT and in particular slope, were predictors for PVR. Thus, echocardiography appears appropriate in the management of patients with PR.

  2. Assessment of atrial fibrillation and vulnerability in patients with Wolff-Parkinson-White syndrome using two-dimensional speckle tracking echocardiography.

    Science.gov (United States)

    Li, Jing-Jie; Wei, Fang; Chen, Ju-Gang; Yu, Yan-Wei; Gu, Hong-Yue; Jiang, Rui; Wu, Xiu-Li; Sun, Qian

    2014-01-01

    The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE). All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls. Results showed significant differences in both body mass index (BMI) and supraventricular tachycardia (SVT) duration between WPW patients and DAVNP patients (both Psyndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period.

  3. Retinopathy is associated with impaired myocardial function assessed by advanced echocardiography in type 1 diabetes patients – The Thousand & 1 Study

    DEFF Research Database (Denmark)

    Nouhravesh, Nina; Andersen, Henrik U; Jensen, Jan S

    2016-01-01

    AIMS: Retinopathy and heart disease in Type 1 Diabetes Mellitus (Type 1 DM) may be associated; however previous results have been conflicting. Tissue Doppler Imaging (TDI) and speckle-tracking echocardiography (STE) quantify myocardial function not assessable by conventional echocardiography. We...... investigated the association between severity of retinopathy and early myocardial dysfunction using conventional echocardiography, TDI and STE in Type 1 DM patients. METHODS: Type 1 Diabetes Mellitus patients without known heart disease were included from the Steno Diabetes Center. The cross sectional...... association between retinopathy and myocardial function was analyzed in uni-and multivariable models. Retinopathy was categorized as nil-, simplex- or proliferative retinopathy. RESULTS: A total of 1090 Type 1 Diabetes Mellitus patients were included, mean age was 49.6years and 53% were males. Left...

  4. Making three-dimensional echocardiography more tangible: a workflow for three-dimensional printing with echocardiographic data

    Directory of Open Access Journals (Sweden)

    Azad Mashari MD

    2016-12-01

    Full Text Available Three-dimensional (3D printing is a rapidly evolving technology with several potential applications in the diagnosis and management of cardiac disease. Recently, 3D printing (i.e. rapid prototyping derived from 3D transesophageal echocardiography (TEE has become possible. Due to the multiple steps involved and the specific equipment required for each step, it might be difficult to start implementing echocardiography-derived 3D printing in a clinical setting. In this review, we provide an overview of this process, including its logistics and organization of tools and materials, 3D TEE image acquisition strategies, data export, format conversion, segmentation, and printing. Generation of patient-specific models of cardiac anatomy from echocardiographic data is a feasible, practical application of 3D printing technology.

  5. The washout rate of (123)I-BMIPP and the evolution of left ventricular function in patients with successfully reperfused ST-segment elevation myocardial infarction: comparisons with the echocardiography.

    Science.gov (United States)

    Biswas, Shankar K; Sarai, Masayoshi; Yamada, Akira; Toyama, Hiroshi; Motoyama, Sadako; Harigaya, Hiroto; Hara, Tomonori; Naruse, Hiroyuki; Hishida, Hitoshi; Ozaki, Yukio

    2010-02-01

    The evolution of the oxidative metabolism of (11)C acetate parallels the recovery of left ventricular(LV) contraction following acute myocardial infarction(AMI). This study was designed to unravel, for the first time, the impact of the global washout rate(WR) of (123)I-beta-methyl-p-iodophenylpentadecanoic acid (BMIPP) on the recovery of LV function followingAMI, as evidenced from conventional echocardiography.Twenty consecutive patients (age: 58 +/- 13 years; 16 males and 4 females) with ST-segment elevation myocardial infarction (STEMI) were enrolled and all of them underwent successful percutaneous coronary intervention (PCI). (123)I-BMIPP cardiac scintigraphy was performed at 7 +/- 3 days after admission. The WR was calculated from the polar map and the regional BMIPP defect score was calculated using a 17 segment model. Echocardiography was performed within 24 h of admission and at 3 months to record the ejection fraction (EF), the wall motion score index (WMSI), the ratio of the mitralinflow velocity to the early diastolic velocity (E/E0)and the myocardial performance index (MPI). The mean global WR of the BMIPP was 22.12 +/- 7.22%, and it was significantly correlated with the improvement of the WMSI (r = 0.61, P\\0.004). However,the relative changes of the EF, E/E0 and MPI were not correlated with the WR. The BMIPP defect score (18 +/- 10) was significantly correlated with the WMSI on admission (r = 0.74, P = 0.0002), but the defect score was not correlated with the relative changes of any of the echocardiographic parameters. We proved that the WR of the BMIPP is a promising indicator of improvement of the LV wall motion (WMSI) following ST-segment elevation myocardial infarction and successful reperfusion.

  6. A comparison of left ventricular mass between two-dimensional echocardiography, using fundamental and tissue harmonic imaging, and cardiac MRI in patients with hypertension

    International Nuclear Information System (INIS)

    Alfakih, Khaled; Bloomer, Tim; Bainbridge, Samantha; Bainbridge, Gavin; Ridgway, John; Williams, Gordon; Sivananthan, Mohan

    2004-01-01

    Purpose: To compare left ventricular mass (LVM) as measured by two-dimensional (2D) echocardiography using two different calculation methods: truncated ellipse (TE) and area length (AL), in both fundamental and tissue harmonic imaging frequencies, to LVM as measured by, the current gold standard, cardiac magnetic resonance imaging (MRI). Turbo gradient echo (TGE) pulse sequence was utilized for MRI. Materials and methods: Thirty-two subjects with history of hypertension were recruited. The images were acquired, contours were traced and the LVM was calculated for all four different echocardiography methods as well as for the cardiac MRI method. The intra-observer variabilities were calculated. The four different echocardiography methods were compared to cardiac MRI using the method described by Bland and Altman. Results: Twenty-five subjects had adequate paired data sets. The mean LVM as measured by cardiac MRI was 162±55 g and for the four different echocardiography methods were: fundamental AL 165±55 g, harmonic AL 168±53 g, fundamental TE 148±50 g, harmonic TE 149±45 g. The intra-observer variability for cardiac MRI method, expressed as bias ± 1 standard deviation of the difference (S.D.D.), was 2.3±9.2 g and for the four different echocardiography methods were: fundamental TE 0.4±26.8 g, fundamental AL 0.6±27.0 g, harmonic TE 6.7±21.8 g, harmonic AL 6.4±22.9 g. The mean LVM for the AL method was closest to the cardiac MRI technique, while TE underestimated LVM. The 95% limits of agreement were consistently wide for all the 2D echocardiography modalities when compared with the cardiac MRI technique. Conclusion: The intra-observer variability in measurements of 2D echocardiographic LVM, together with the wide limits of agreement when compared to the gold standard (cardiac MRI) are sufficiently large to make serial estimates of LVM, of single patients or small groups of subjects, by 2D echocardiography, unreliable

  7. Blood Pool Contrast-enhanced Magnetic Resonance Angiography with Correlation to Digital Subtraction Angiography: A Pictorial Review

    Directory of Open Access Journals (Sweden)

    Martha-Grace Knuttinen

    2014-01-01

    Full Text Available Magnetic resonance angiography (MRA provides noninvasive visualization of the vascular supply of soft tissue masses and vascular pathology, without harmful radiation. This is important for planning an endovascular intervention, and helps to evaluate the efficiency and effectiveness of the treatment. MRA with conventional extracellular contrast agents relies on accurate contrast bolus timing, limiting the imaging window to first-pass arterial phase. The recently introduced blood pool contrast agent (BPCA, gadofosveset trisodium, reversibly binds to human serum albumin, resulting in increased T1 relaxivity and prolonged intravascular retention time, permitting both first-pass and steady-state phase high-resolution imaging. In our practice, high-quality MRA serves as a detailed "roadmap" for the needed endovascular intervention. Cases of aortoiliac occlusive disease, inferior vena cava thrombus, pelvic congestion syndrome, and lower extremity arteriovenous malformation are discussed in this article. MRA was acquired at 1.5 T with an 8-channel phased array coil after intravenous administration of gadofosveset (0.03 mmol/kg body weight, at the first-pass phase. In the steady-state, serial T1-weighted 3D spoiled gradient echo images were obtained with high resolution. All patients underwent digital subtraction angiography (DSA and endovascular treatment. MRA and DSA findings of vascular anatomy and pathology are discussed and correlated. BPCA-enhanced MRA provides high-quality first-pass and steady-state vascular imaging. This could increase the diagnostic accuracy and create a detailed map for pre-intervention planning. Understanding the pharmacokinetics of BPCA and being familiar with the indications and technique of MRA are important for diagnosis and endovascular intervention.

  8. Intracardiac Echocardiography Evaluation in Secundum Atrial Septal Defect Transcatheter Closure

    International Nuclear Information System (INIS)

    Zanchetta, Mario; Pedon, Luigi; Rigatelli, Gianluca; Carrozza, Antonio; Zennaro, Marco; Di Martino, Roberta; Onorato, Eustaquio; Maiolino, Pietro

    2003-01-01

    Purpose: This study was designed to assess the balloon sizing maneuvers and deployment of an Amplatzer Septal Occluder (ASO). In addition, intraprocedural balloon sizing was compared with off-line intracardiac echocardiographic measurements. Methods: The intracardiac echocardiography (ICE) measurements were: maximum transverse and longitudinal atrial septal defect (ASD) diameters in the aortic valve and four-chamber planes;area of the ASD and its equivalent circle diameter. Thirteen consecutive patients underwent transcatheter implantation of an ASO device using ICE guidance under local anesthesia. The device matching the balloon sizing diameter of the defect was implanted. Qualitative ICE assessment of the ASO devices implanted was performed off line. Results: The mean equivalent circle diameter predicted by ICE was 24.40 ± 5.61 mm and was significantly higher(p 0.027) than the ASD measured by balloonsizing (21.38 ± 5.28 mm). Unlike previous studies we did not find any correlation between the two measurements (correlation coefficient = 0.47). Only four of the 13 patients had optimal device positioning as shown by the qualitative ICE evaluation, whereas the remaining nine patients had inadequate device placement. This resulted in a waist diameter that was an average 26.1% undersized in seven patients and 12.7% oversized in two patients. Five of the seven patients with an undersized device had ASO-atrial septum misalignment with leftward device deviation. Conclusion: The ICE images allowed careful measurement of the dimensions of the ASD and accurately displayed the spatial relations of the ASO astride the ASD.Moreover, use of the ICE measurement led to selection of a different size of device in comparison with those of balloon sizing. The clinical benefit of this new approach needs to be rigorously tested

  9. Indium-111 platelet scintigraphy and two-dimensional echocardiography for detection of left ventricular thrombus: influence of clot size and age

    International Nuclear Information System (INIS)

    Seabold, J.E.; Schroeder, E.C.; Conrad, G.R.

    1987-01-01

    Two-dimensional echocardiography and indium-111 platelet scintigraphy were performed on 50 dogs to determine the influence of clot age and size on the detection of experimentally induced left ventricular mural thrombus. Thrombus was induced by apical infarction and injection of a sclerosing agent and thrombin. The animals were classified into four groups according to the time of indium-111 platelet injection after thrombus induction: Group I (17 dogs, 1/2 hour after induction; 3 dogs, before induction), Group II (12 dogs, 24 hours after induction) and Group III (12 dogs, 1 week after induction). In Group IV (six control dogs) apical infarction was produced, but thrombin was not injected; indium-111 platelets were injected 1/2 to 1 hour after infarction. The dogs were studied by indium-111 platelet scintigraphy and by two-dimensional echocardiography 1/2 to 5 hours (Group I) and 1 to 5 and up to 72 hours (Groups II to IV) after platelet administration and before death was induced. Two-dimensional echocardiography showed the best overall sensitivity for detection of acute thrombus (97%; 29 of 30). The sensitivity of indium-111 platelet scintigraphy was 86% (18 of 21) for clots greater than or equal to 0.08 ml in size, and 67% (20 of 30) for detection of all clots. Thrombus did not form in 14 dogs of Groups I to III and in 6 of 6 control dogs. The specificity of scintigraphy was 100% (20 of 20) compared with 80% (16 of 20) for echocardiography. Echocardiography was more sensitive than scintigraphy for detecting very small clots in this experimental model

  10. Detection of hibernating myocardium in patients with myocardial infarction by low-dose dobutamine echocardiography. Comparison with thallium-201 scintigraphy with reinjection

    International Nuclear Information System (INIS)

    Takagi, Tsutomu; Yoshikawa, Junichi; Yoshida, Kiyoshi; Akasaka, Takashi; Honda, Yasuhiro; Yonezawa, Yoshihiro; Shakudo, Masahiro

    1995-01-01

    The identification of hibernating myocardium is important for selecting patients who will benefit from coronary revascularization. The relationship between echocardiographic and radioisotopic markers of hibernating myocardium and postrevascularization recovery of myocardial function was investigated in 21 patients who underwent successful revascularization. Each patient underwent low-dose dobutamine stress echocardiography and thallium-201 ( 201 Tl) scintigraphy with reinjection before revascularization. The presence of contractile reserve in dobutamine stress echocardiography and Tl uptake in 201 Tl scintigraphy with reinjection were defined as markers of hibernating myocardium. Follow-up echocardiograms were evaluated for improved regional wall motion in all patients at a mean of 8.6 months after revascularization. Sensitivity, specificity, and positive and negative predictive values of low-dose dobutamine stress echocardiography for indicating recovery of function after revascularization were 75.0%, 77.8%, 81.8%, and 70.0%, respectively. Sensitivity, specificity, and positive and negative predictive values of 201 Tl scintigraphy with reinjection for indicating recovery of function after revascularization were 91.7%, 55.6%, 73.3%, and 83.3%, respectively. There were no statistical differences between low-dose dobutamine echocardiography and 201 Tl scintigraphy in predicting postrevascularization recovery of function in patients with hibernating myocardium. (author)

  11. Myocardial delayed contrast enhancement in patients with arterial hypertension: Initial results of cardiac MRI

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, Kjel [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: kjel_andersen@web.de; Hennersdorf, Marcus [Department of Cardiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: hennersdorf@med.uni-duesseldorf.de; Cohnen, Mathias [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: cohnen@med.uni-duesseldorf.de; Blondin, Dirk [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: blondin@med.uni-duesseldorf.de; Moedder, Ulrich [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: moedder@uni-duesseldorf.de; Poll, Ludger W. [Institute of Diagnostic Radiology, University Hospital Duesseldorf, Moorenstr. 5, 40225 Duesseldorf (Germany)], E-mail: poll@gmx.de

    2009-07-15

    Purpose: In arterial hypertension left ventricular hypertrophy comprises myocyte hypertrophy, interstitial fibrosis and structural alterations of the coronary microcirculation. MRI enables the detection of myocardial fibrosis, infarction and scar tissue by delayed enhancement (DE) after contrast media application. Aim of this study was to investigate patients with arterial hypertension but without known coronary disease or previous myocardial infarction to detect areas of DE. Methods and material: Twenty patients with arterial hypertension with clinical symptoms of myocardial ischemia, but without history of myocardial infarction and normal coronary arteries during coronary angiography were investigated on a 1.0 T superconducting magnet (Gyroscan T10-NT, Intera Release 8.0, Philips). Fast gradient-echo cine sequences and T2-weighted STIR-sequences were acquired. Fifteen minutes after injection of Gadobenate dimeglumine inversion recovery gradient-echo sequences were performed for detection of myocardial DE. Presence or absence of DE on MRI was correlated with clinical data and the results of echocardiography and electrocardiography, respectively. Results: Nine of 20 patients showed DE in the interventricular septum and the anteroseptal left ventricular wall. In 6 patients, DE was localized intramurally and in 3 patients subendocardially. There was a significant correlation between myocardial DE and ST-segment depressions during exercise and between DE and left-ventricular enddiastolic pressure. Patients with intermittent atrial fibrillation showed a myocardial DE more often than patients without atrial fibrillation. Conclusion: In our series, 45% of patients with arterial hypertension showed DE on cardiac MRI. In this clinical setting, delayed enhancement may be due to coronary microangiopathy. The more intramurally localization of DE, however, rather indicates myocardial interstitial fibrosis.

  12. Myocardial delayed contrast enhancement in patients with arterial hypertension: Initial results of cardiac MRI

    International Nuclear Information System (INIS)

    Andersen, Kjel; Hennersdorf, Marcus; Cohnen, Mathias; Blondin, Dirk; Moedder, Ulrich; Poll, Ludger W.

    2009-01-01

    Purpose: In arterial hypertension left ventricular hypertrophy comprises myocyte hypertrophy, interstitial fibrosis and structural alterations of the coronary microcirculation. MRI enables the detection of myocardial fibrosis, infarction and scar tissue by delayed enhancement (DE) after contrast media application. Aim of this study was to investigate patients with arterial hypertension but without known coronary disease or previous myocardial infarction to detect areas of DE. Methods and material: Twenty patients with arterial hypertension with clinical symptoms of myocardial ischemia, but without history of myocardial infarction and normal coronary arteries during coronary angiography were investigated on a 1.0 T superconducting magnet (Gyroscan T10-NT, Intera Release 8.0, Philips). Fast gradient-echo cine sequences and T2-weighted STIR-sequences were acquired. Fifteen minutes after injection of Gadobenate dimeglumine inversion recovery gradient-echo sequences were performed for detection of myocardial DE. Presence or absence of DE on MRI was correlated with clinical data and the results of echocardiography and electrocardiography, respectively. Results: Nine of 20 patients showed DE in the interventricular septum and the anteroseptal left ventricular wall. In 6 patients, DE was localized intramurally and in 3 patients subendocardially. There was a significant correlation between myocardial DE and ST-segment depressions during exercise and between DE and left-ventricular enddiastolic pressure. Patients with intermittent atrial fibrillation showed a myocardial DE more often than patients without atrial fibrillation. Conclusion: In our series, 45% of patients with arterial hypertension showed DE on cardiac MRI. In this clinical setting, delayed enhancement may be due to coronary microangiopathy. The more intramurally localization of DE, however, rather indicates myocardial interstitial fibrosis.

  13. Role of echocardiography for catheter-based management of valvular heart disease.

    Science.gov (United States)

    Shiota, Takahiro

    2017-01-01

    Catheter-based treatment of valvular heart disease, such as transvalvular aortic valve replacement (TAVR) or mitral clip procedure, has been increasingly accepted as a treatment choice for the past several years. Such new treatment options have been changing the management of patients with valvular heart disease drastically while socio-economic factors regarding their application need to be taken into consideration. The use of echocardiography, including transesophageal echocardiography (TEE), for such catheter-based treatments is essential for the success of the procedures. Severe hypotension after TAVR is a life-threatening emergency. Rapid assessment and diagnosis in the catheterization or hybrid laboratory is essential for safety and a positive outcome. Possible diagnoses in this critical situation would include severe left ventricular dysfunction due to coronary obstruction, cardiac tamponade, aortic rupture, acute severe aortic and/or mitral valve regurgitation, and hypovolemia due to bleeding. Although new types of TAVR valves reduce para-valvular aortic regurgitation (AR) significantly, it is still important to judge the severity of para-valvular AR correctly in the laboratory. As for mitral clip procedure, TEE is vital for guiding and monitoring the entire process. Accurate identification of the location and the geometry of the regurgitant orifice is necessary for proper placement of the clip. Real-time 3D TEE provides helpful en face view of the mitral valve and clip together to this end. Residual mitral regurgitation (MR) after the first clip is not uncommon. Quick and precise imaging of the residual MR (location and severity) with TEE is extremely important for the interventionist to place the second clip and possibly third clip properly. After the completion of the clip procedure, mitral valve stenosis and also iatrogenic atrial septal defect need to be checked by TEE. Echocardiography, especially TEE, is also vital for the success of other newer trans

  14. Outcomes in Asymptomatic Severe Aortic Stenosis With Preserved Ejection Fraction Undergoing Rest and Treadmill Stress Echocardiography.

    Science.gov (United States)

    Huded, Chetan P; Masri, Ahmad; Kusunose, Kenya; Goodman, Andrew L; Grimm, Richard A; Gillinov, A Marc; Johnston, Douglas R; Rodriguez, L Leonardo; Popovic, Zoran B; Svensson, Lars G; Griffin, Brian P; Desai, Milind Y

    2018-04-12

    In asymptomatic patients with severe aortic stenosis and preserved left ventricular ejection fraction, we sought to assess the incremental prognostic value of resting valvuloarterial impedence (Zva) and left ventricular global longitudinal strain (LV-GLS) to treadmill stress echocardiography. We studied 504 such patients (66±12 years, 78% men, 32% with coronary artery disease who underwent treadmill stress echocardiography between 2001 and 2012. Clinical and exercise variables (% of age-sex predicted metabolic equivalents [%AGP-METs]) were recorded. Resting Zva ([systolic arterial pressure+mean aortic valve gradient]/[LV-stroke volume index]) and LV-GLS (measured offline using Velocity Vector Imaging, Siemens) were obtained from the baseline resting echocardiogram. Death was the primary outcome. There were no major adverse cardiac events during treadmill stress echocardiography. Indexed aortic valve area, Zva, and LV-GLS were 0.46±0.1 cm 2 /m 2 , 4.5±0.9 mm Hg/mL per m 2 and -16±4%, respectively; only 50% achieved >100% AGP-METs. Sixty-four percent underwent aortic valve replacement. Death occurred in 164 (33%) patients over 8.9±3.6 years (2 within 30 days of aortic valve replacement). On multivariable Cox survival analysis, higher Society of Thoracic Surgeons score (hazard ratio or HR 1.06), lower % AGP-METS (HR 1.16), higher Zva (HR 1.25) and lower LV-GLS (HR 1.12) were associated with higher longer-term mortality, while aortic valve replacement (HR 0.45) was associated with improved survival (all P statistic from 0.65 to 0.69 and 0.75, respectively, both P stress echocardiography, LV-GLS and ZVa offer incremental prognostic value. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  15. Could parenchymal enhancement on contrast-enhanced spectral mammography (CESM) represent a new breast cancer risk factor? Correlation with known radiology risk factors.

    Science.gov (United States)

    Savaridas, S L; Taylor, D B; Gunawardana, D; Phillips, M

    2017-12-01

    To compare background parenchymal enhancement (BPE) on contrast-enhanced (CE) spectral mammography (CESM) with CE magnetic resonance imaging (MRI), and evaluate how these relate to hormonal status, mammographic breast density (MBD) and MRI fibroglandular tissue volume (FGTV). Between June 2012 to October 2015, participants in a cancer staging study underwent full-field digital mammography (FFDM), CEMRI, and CESM. Two readers independently rated FGTV, MBD, and BPE using the Breast Imaging-Reporting and Data System (BI-RADS) criteria. Inter-reader reliability was estimated using weighted kappa (k) and correlations between BPE, MBD, and FGTV calculated using Spearman's correlation coefficient. Associations with hormonal status were evaluated using multilevel ordinal regression analysis. Of the 96 eligible participants, 66 women (35-77 years) underwent CESM and CEMRI. Reasons for exclusion were declined or withdrawn consent (n=18), inadequate renal function (n=2), claustrophobia (n=2), previous reaction to contrast medium (n=2), mild reaction to contrast medium following CESM (n=2), lack of vascular access (n=1), neoadjuvant chemotherapy (n=1), CESM equipment failure (n=1), and unclear in one case. Inter-reader agreement was substantial (k=0.67) for CESM BPE, slight (k=0.19) for CEMRI BPE, moderate (k=0.57) for MRI FGTV and fair (k=0.35) for MBD. CESM BPE showed significant correlation with MBD (rho=0.36, p<0.0001), FGTV (rho=0.52, p<0.0001), and MRI BPE (rho=0.49, p<0.0001). BPE was significantly reduced in the post-menopausal group for CEMRI and CESM (p<0.05). CESM BPE did not significantly fluctuate during the menstrual cycle. CESM BPE is correlated with MBD, FGTV, and CEMRI BPE, has better inter-reader reliability than CEMRI, and is not influenced by the menstrual cycle. Grading the degree of BPE on CESM could be a useful addition to breast cancer risk assessment tools. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights

  16. A wide variety of dynamic contrast-enhanced MR appearances of breast cancer: Pathologic correlation study

    International Nuclear Information System (INIS)

    Onishi, Masayuki; Furukawa, Akira; Takahashi, Masashi; Murata, Kiyoshi

    2008-01-01

    Purpose: The aim of this study was to elucidate the characteristic magnetic resonance (MR) appearance of breast cancers, as well as, its variations and to investigate the pathology providing different patterns of dynamic-MR appearances. Materials and methods: Fifty-two women with cancer underwent mastectomy (52 tumors resected) and had MR imaging at our institution between April 2001 and March 2004. MR images of T1WI, T2WI, dynamic-MRI and contrast-enhanced T1WI were obtained and evaluated. Dynamic-MR images were correlated with pathological findings. Results: Common MR appearance of breast cancer was a focal mass either with irregular or spiculated margins with similar signal intensity on T1WI as and similar to higher signal intensity on T2WI compared to the normal mammary gland. On static contrast-enhanced T1WI, apparent enhancement was typically observed. On dynamic MRI, tumor-rim-enhancement on an early phase image and washout enhancement pattern on dynamic images, both characteristic for breast cancer, were observed, however, the prevalence of them was relatively low, which could be explained by the variation of histopathology among breast cancer nodules. Conclusion: In diagnosing breast masses on MRI, as well as the common and characteristic findings of breast cancer, the variations of MR findings and their underlying histopathology should also be considered

  17. Three-dimensional transesophageal echocardiography: Principles and clinical applications

    Directory of Open Access Journals (Sweden)

    Annette Vegas

    2016-01-01

    Full Text Available A basic understanding of evolving 3D technology enables the echocardiographer to master the new skills necessary to acquire, manipulate, and interpret 3D datasets. Single button activation of specific 3D imaging modes for both TEE and transthoracic echocardiography (TTE matrix array probes include (a live, (b zoom, (c full volume (FV, and (d color Doppler FV. Evaluation of regional LV wall motion by RT 3D TEE is based on a change in LV chamber subvolume over time from altered segmental myocardial contractility. Unlike standard 2D TEE, there is no direct measurement of myocardial thickening or displacement of individual segments.

  18. Anatomy of the normal fetal heart: The basis for understanding fetal echocardiography

    Directory of Open Access Journals (Sweden)

    Beatriz Picazo-Angelin

    2018-01-01

    Full Text Available The rapid changes that have taken place in recent years in relation to techniques used to image the fetal heart have emphasized the need to have a detailed knowledge ofnormal cardiac anatomy. Without such knowledge, it is difficult, if not impossible, to recognize the multiple facets of congenital cardiac disease. From the inception of fetal echocardiographic screening, the importance of basic knowledge of cardiac anatomy has been well recognized. The current machines used for imaging, however, now make it possible potentially to recognize features not appreciated at the start of the specialty. So as to match the advances made in imaging, we have now revisited our understanding of normal cardiac anatomy in the mid-gestational fetus. This was made possible by our dissection of 10 fetal hearts, followed by production of addition histological sections that mimic the standard ultrasound views. The fetuses ranged in gestational age from between 20 and 28 weeks. We then correlated the obtained anatomic images with the corresponding ultrasonic images used in the standard fetal screening scan. We also interrogated the anatomic sections so as to clarify ongoing controversies regarding detailed features of the normal cardiac anatomy. We have been able to show that the views now obtained using current technology reveal many details of anatomy not always appreciated at earlier times. Knowledge of these features should now permit diagnosis of most congenital cardiac malformations. The anatomic-echocardiographic correlations additionally provide a valuable resource for both the understanding and teaching of fetal echocardiography.

  19. Role of echocardiography in diagnosis and management of complete papillary muscle rupture caused by myocardial infarction

    Directory of Open Access Journals (Sweden)

    Josip Vincelj

    2015-08-01

    Full Text Available Aim To evaluate the usefulness of echocardiography in the diagnosis of complete rupture of papillary muscle. Methods Transthoracic (TTE and transesophageal echocardiography (TEE was performed with the ATL 3000 HDI Ultrasound Inc (Bothell, WA, USA with a 2.5 MHz transducer and 5-7 MHz multiplane phased array transducer. We are reporting about two patients (a 45 and a 51-year old male with complete ruptures of papillary muscle following acute myocardial infarction (AMI. Results Both patients were previously treated with fibrinolysis in their local hospitals, 400 and 300 km, respectively, away from our hospital. Massive mitral regurgitation developed in both followed by rapid deterioration of hemodynamic state and severe heart failure, because of which both were transferred by helicopter to the Coronary Care Unit of our clinic. The diagnosis of complete papillary muscle rupture was confirmed in both patients by TTE and TEE. Due to the significant deterioration in their hemodynamic state, vasoactive drugs and intra-aortic balloon pump support were applied. Both patients then underwent mitral valve replacement, accompanied by concomitant coronary artery bypass grafting in one case. Conclusion Transesophageal echocardiography is a more accurate and rapid diagnostic method in patients with mechanical complications of AMI than TTE.

  20. Correlation between a 2D Channelized Hotelling Observer and Human Observers in a Low-contrast Detection Task with Multi-slice Reading in CT

    Science.gov (United States)

    Yu, Lifeng; Chen, Baiyu; Kofler, James M.; Favazza, Christopher P.; Leng, Shuai; Kupinski, Matthew A.; McCollough, Cynthia H.

    2017-01-01

    Purpose Model observers have been successfully developed and used to assess the quality of static 2D CT images. However, radiologists typically read images by paging through multiple 2D slices (i.e. multi-slice reading). The purpose of this study was to correlate human and model observer performance in a low-contrast detection task performed using both 2D and multi-slice reading, and to determine if the 2D model observer still correlate well with human observer performance in multi-slice reading. Methods A phantom containing 18 low-contrast spheres (6 sizes × 3 contrast levels) was scanned on a 192-slice CT scanner at 5 dose levels (CTDIvol = 27, 13.5, 6.8, 3.4, and 1.7 mGy), each repeated 100 times. Images were reconstructed using both filtered-backprojection (FBP) and an iterative reconstruction (IR) method (ADMIRE, Siemens). A 3D volume of interest (VOI) around each sphere was extracted and placed side-by-side with a signal-absent VOI to create a 2-alternative forced choice (2AFC) trial. Sixteen 2AFC studies were generated, each with 100 trials, to evaluate the impact of radiation dose, lesion size and contrast, and reconstruction methods on object detection. In total, 1600 trials were presented to both model and human observers. Three medical physicists acted as human observers and were allowed to page through the 3D volumes to make a decision for each 2AFC trial. The human observer performance was compared with the performance of a multi-slice channelized Hotelling observer (CHO_MS), which integrates multi-slice image data, and with the performance of previously validated CHO, which operates on static 2D images (CHO_2D). For comparison, the same 16 2AFC studies were also performed in a 2D viewing mode by the human observers and compared with the multi-slice viewing performance and the two CHO models. Results Human observer performance was well correlated with the CHO_2D performance in the 2D viewing mode (Pearson product-moment correlation coefficient R=0

  1. Contrasts and effect sizes in behavioral research: a correlational approach

    National Research Council Canada - National Science Library

    Rosenthal, Robert; Rosnow, Ralph L; Rubin, Donald B

    2000-01-01

    .... Researchers, teachers of research methods, and graduate students will be familiar with the principles and procedures of contrast analysis but will also be introduced to a series of newly developed...

  2. Clinical Efficacy of Transthoracic Echocardiography for Screening Abdominal Aortic Aneurysm in Turkish Patients.

    Science.gov (United States)

    Kilic, Salih; Saracoglu, Erhan; Cekici, Yusuf

    2018-03-01

    The objective of this study was to investigate the prevalence of abdominal aortic aneurysm (AAA) in Turkish patients aged ≥ 65 years, and to demonstrate the applicability of echocardiography to AAA screening. Transthoracic echocardiography (TTE) was performed in all consecutive patients aged ≥ 65 years who were referred to cardiology clinics or were referred from other outpatient clinics. The abdominal aorta (AA) of each patient was scanned using the same probe, and the time spent was recorded. Demographic and clinic characteristics of the patients were recorded at the end of the echocardiography. Among 1948 patients (mean age 70.9 ± 6 years; 49.8% male), the AA was visualized in 96.3%. AAA was identified in 3.7% (69/1878) of the patients, of whom AAA was previously known in 20.3% (n = 14). The prevalence of unknown AAA was 2.93%. The average time needed to scan and measure the AA was 1 minute and 3 seconds (±23 seconds). Aortic root diameters were significantly higher in the patients with AAA than in those without AAA (34.7 ± 4.2 vs. 29.8 ± 4.7; p < 0.001). Age (per 1 year increase) [odds ratio (OR), 1.245; p < 0.001], male gender (OR, 5.382; p < 0.001), smoking (OR, 2.118; p = 0.037), and aortic root diameter (per 1 mm increase) (OR, 1.299; p < 0.001) were independent predictors of AAA. This study is important in that it showed a high prevalence of AAA in Turkish patients aged ≥ 65 years, and demonstrated that AAA can be visualized in the majority of patients in as little as 1 minute during TTE.

  3. Clinical study on left atrial thrombi. Comparative study between echocardiography and CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, E; Asano, H; Kurasawa, T; Mitsumoto, K; Yamane, Y [Tokyo Kosei-Nenkin Hospital (Japan)

    1981-09-01

    We studied left atrial thrombi (LAT) by both echocardiography and computed tomography (CT) and compared the features of the 2 methods. A total of 15 patients with mitral stenosis complicated by atrial fibrillation were selected as the subjects. LAT were noted on the M-mode echocardiograms in 2 patients including a questionably positive one, on the two-dimensional echocardiograms in 5, and on the CT scans in 6 of 15. The history of thromboembolism was rather frequent and was found in 7 of 15 patients. However, LAT was found in only 3 of these on the CT scans. A shaggy or fuzzy pattern on the M-mode echocardiogram cannot be regarded as representing thrombi, while a laminar pattern undoubtedly represented thrombi. Two-dimensional echocardiography has considerably contributed to the improved detection rate of LAT. For the characteristic properties of ultrasound beams, however, it was impossible to investigate the entire left atrium. The detection of the thrombi in the appendage was especially difficult. However, computed tomography, permitting transverse cross-sectional tomography, was capable of sectioning the heart even in the presence of air and bones. The measurement of CT values was suggestive of the properties of the substance or substances involved, and also allowed the presumption as to whether the thrombus has been fibrosed. Furthermore, it was possible to estimate more accurately as well as 3-dimensionally the location, shape and dimensions of the thrombi by the reconstruction of the heart according to the CT values. It was concluded that echocardiography and computed tomography are the mutual aid to further improvement in the detection rate of left atrial thrombi.

  4. P-02: Echocardiography Has Low Clinical Efficacy of Libyan Screening Protocol in Athletes

    Directory of Open Access Journals (Sweden)

    Salaheddin Sharif

    2017-03-01

    Full Text Available INTRODUCTIONPre-participation screening has been largely accepted as a means to identify those athletes at risk of cardiovascular diseases which are responsible for sudden cardiac death. The objectives of athlete screening are to reduce injuries and prevent sudden. However, there is no single commonly adopted protocol to screen athletes. Although the European Society of Cardiology and the American Heart Association recommend the routine screening of athletes to prevent sudden death, there is significant disagreement regarding use 12 lead ECG. FIFA has recommend the inclusion of an Echocardiography (ECHO in screening protocol.PURPOSEExplore the debate regarding differences between European and the USA pre-participation screening protocol for sudden death while also considering pre-competition medical assessment protocol used by the Libyan Football Federation. To provide evidence based recommendations on the best protocol to be used for pre-participation screening, and thus to standardize the screening method.MATERIALS and METHOD1236 male athletic received a medical history, general physical examination, cardiovascular and musculoskeletal examination, 12 lead ECG, blood laboratory test, and echocardiography.FINDINGS1235 athletics were found to be eligible to participate in sport and were given a full medical clearance. One athletic was diagnosed with second degree heart block by ECG while his medical history, physical examination, echocardiograph, and blood test were normal.DISCUSSIONEchocardiography alone do did not identify pathological condition and using echocardiography is still controversial and clinically not effective in young athletesCONCLUSIONThe Screening protocol should include a combination of medical history, physical examination and ECG due to the high sensitivity found, and thus it was able to identify all athletes at risk for the disease.

  5. Real-time 3-dimensional fetal echocardiography with an instantaneous volume-rendered display: early description and pictorial essay.

    Science.gov (United States)

    Sklansky, Mark S; DeVore, Greggory R; Wong, Pierre C

    2004-02-01

    Random fetal motion, rapid fetal heart rates, and cumbersome processing algorithms have limited reconstructive approaches to 3-dimensional fetal cardiac imaging. Given the recent development of real-time, instantaneous volume-rendered sonographic displays of volume data, we sought to apply this technology to fetal cardiac imaging. We obtained 1 to 6 volume data sets on each of 30 fetal hearts referred for formal fetal echocardiography. Each volume data set was acquired over 2 to 8 seconds and stored on the system's hard drive. Rendered images were subsequently processed to optimize translucency, smoothing, and orientation and cropped to reveal "surgeon's eye views" of clinically relevant anatomic structures. Qualitative comparison was made with conventional fetal echocardiography for each subject. Volume-rendered displays identified all major abnormalities but failed to identify small ventricular septal defects in 2 patients. Important planes and views not visualized during the actual scans were generated with minimal processing of rendered image displays. Volume-rendered displays tended to have slightly inferior image quality compared with conventional 2-dimensional images. Real-time 3-dimensional echocardiography with instantaneous volume-rendered displays of the fetal heart represents a new approach to fetal cardiac imaging with tremendous clinical potential.

  6. Role of modern 3D echocardiography in valvular heart disease

    Science.gov (United States)

    2014-01-01

    Three-dimensional (3D) echocardiography has been conceived as one of the most promising methods for the diagnosis of valvular heart disease, and recently has become an integral clinical tool thanks to the development of high quality real-time transesophageal echocardiography (TEE). In particular, for mitral valve diseases, this new approach has proven to be the most unique, powerful, and convincing method for understanding the complicated anatomy of the mitral valve and its dynamism. The method has been useful for surgical management, including robotic mitral valve repair. Moreover, this method has become indispensable for nonsurgical mitral procedures such as edge to edge mitral repair and transcatheter closure of paravaluvular leaks. In addition, color Doppler 3D echo has been valuable to identify the location of the regurgitant orifice and the severity of the mitral regurgitation. For aortic and tricuspid valve diseases, this method may not be quite as valuable as for the mitral valve. However, the necessity of 3D echo is recognized for certain situations even for these valves, such as for evaluating the aortic annulus for transcatheter aortic valve implantation. It is now clear that this method, especially with the continued development of real-time 3D TEE technology, will enhance the diagnosis and management of patients with these valvular heart diseases. PMID:25378966

  7. Myocardial Strain Analysis by 2-Dimensional Speckle Tracking Echocardiography Improves Diagnostics of Coronary Artery Stenosis in Stable Angina Pectoris

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Hoffmann, Soren; Mogelvang, Rasmus

    2014-01-01

    BACKGROUND: Two-dimensional strain echocardiography detects early signs of left ventricular dysfunction; however, it is unknown whether myocardial strain analysis at rest in patients with suspected stable angina pectoris predicts the presence of coronary artery disease (CAD). METHODS AND RESULTS...... echocardiography was performed in the 3 apical projections. Peak regional longitudinal systolic strain was measured in 18 myocardial sites and averaged to provide global longitudinal peak systolic strain. Duke score, including ST-segment depression, chest pain, and exercise capacity, was used as the outcome...

  8. Chemotherapy-Induced Cardiotoxicity: Subclinical Cardiac Dysfunction Evidence Using Speckle Tracking Echocardiography

    OpenAIRE

    Monte, Ines; Bottari, Vera Elena; Buccheri, Sergio; Blundo, Anita; Sirugo, Luana; Leggio, Stefano; Licciardi, Salvatore

    2013-01-01

    Objectives: In our study, we aimed to identify early markers of cardiac dysfunction in patients treated with mitoxantrone. We also looked at cardiac functional changes during therapy by analyzing longitudinal deformation and by measuring left ventricular (LV) and left atrial (LA) global strain. Materials and Methods: LA and LV global longitudinal strain were analyzed in 20 patients affected by multiple sclerosis and treated with mitoxantrone. Patients underwent echocardiography before treatme...

  9. Three-dimensional echocardiography in various types of heart disease: a comparison study of magnetic resonance imaging and 64-slice computed tomography in a real-world population.

    Science.gov (United States)

    Squeri, Angelo; Censi, Stefano; Reverberi, Claudio; Gaibazzi, Nicola; Baldelli, Marco; Binno, Simone Maurizio; Properzi, Enrico; Bosi, Stefano

    2017-03-01

    Accurate quantification of left ventricular (LV) volumes [end-diastolic volume (EDV) and end-systolic volume (ESV)] and ejection fraction (EF) is of critical importance. The development of real-time three-dimensional echocardiography (RT3DE) has shown better correlation than two-dimensional (2D) echocardiography with magnetic resonance imaging (MRI) measurements. The aim of our study was to assess the accuracy of RT3DE and 64-slice computed tomography (CT) in the evaluation of LV volumes and function using MRI as the reference standard in a real-world population with various types of heart disease with different chamber geometry. The study population consisted of 66 patients referred for cardiac MRI for various pathologies. All patients underwent cardiac MRI, and RT3DE and 64 slices CT were then performed on a subsequent day. The study population was then divided into 5 clinical groups depending on the underlying heart disease. RT3DE volumes correlated well with MRI values (R 2 values: 0.90 for EDV and 0.94 for ESV). RT3DE measurements of EF correlated well with MRI values (R 2  = 0.86). RT3DE measurements resulted in slightly underestimated values of both EDV and ESV, as reflected by biases of -9.18 and -4.50 mL, respectively. Comparison of RT3DE and MRI in various types of cardiomyopathies showed no statistical difference between different LV geometrical patterns. These results confirm that RT3DE has good accuracy in everyday clinical practice and can be of clinical utility in all types of cardiomyopathy independently of LV geometric pattern, LV diameter or wall thickness, taking into account a slight underestimation of LV volumes and EF compared to MRI.

  10. Exercise echocardiography for the assessment of pulmonary hypertension in systemic sclerosis: a systematic review.

    Science.gov (United States)

    Baptista, Rui; Serra, Sara; Martins, Rui; Teixeira, Rogério; Castro, Graça; Salvador, Maria João; Pereira da Silva, José António; Santos, Lèlita; Monteiro, Pedro; Pêgo, Mariano

    2016-07-02

    Pulmonary arterial hypertension (PAH) complicates the course of systemic sclerosis (SSc) and is associated with poor prognosis. The elevation of systolic pulmonary arterial pressure (sPAP) during exercise in patients with SSc with normal resting haemodynamics may anticipate the development of PAH. Exercise echocardiography (ExEcho) has been proposed as a useful technique to identify exercise-induced increases in sPAP, but it is unclear how to clinically interpret these findings. In this systematic review, we summarize the available evidence on the role of exercise echocardiography to estimate exercise-induced elevations in pulmonary and left heart filling pressures in patients with systemic sclerosis. We conducted a systematic review of the literature using MEDLINE, Cochrane Library and Web of Knowledge, using the vocabulary terms: ('systemic sclerosis' OR 'scleroderma') AND ('exercise echocardiography') AND ('pulmonary hypertension'). Studies including patients with SSc without a prior diagnosis of PAH, and subjected to exercise echocardiography were included. All searches were limited to English and were augmented by review of bibliographic references from the included studies. The quality of evidence was assessed by the Effective Public Health Practice Project system. We identified 15 studies enrolling 1242 patients, who were mostly middle-aged and female. Several exercise methods were used (cycloergometer, treadmill and Master's two step), with different protocols and positions (supine, semi-supine, upright); definition of a positive test also varied widely. Resting estimated sPAP levels varied from 18 to 35 mm Hg, all in the normal range. The weighted means for estimated sPAP were 22.2 ± 2.9 mmHg at rest and 43.0 ± 4.3 mmHg on exercise; more than half of the studies reported mean exercise sPAP ≥40 mmHg. The assessment of left ventricular diastolic function on peak exercise was reported in a minority of studies; however, when assessed, surrogate

  11. Expert consensus statement 'Neonatologist-performed Echocardiography (NoPE)'-training and accreditation in UK.

    Science.gov (United States)

    Singh, Yogen; Gupta, Samir; Groves, Alan M; Gandhi, Anjum; Thomson, John; Qureshi, Shakeel; Simpson, John M

    2016-02-01

    Targeted echocardiographic assessments of haemodynamic status are increasingly utilised in many settings. Application in the neonatal intensive care units (NICU) is increasingly demanded but challenging given the risk of underlying structural lesions. This statement follows discussions in UK led by the Neonatologists with an Interest in Cardiology and Haemodynamics (NICHe) group in collaboration with the British Congenital Cardiac Association (BCCA) and the Paediatricians with Expertise in Cardiology Special Interest Group (PECSIG). Clear consensus was agreed on multiple aspects of best practice for neonatologist-performed echocardiogram (NoPE)-rigorous attention to infection control and cardiorespiratory/thermal stability, early referral to paediatric cardiology with suspicion of structural disease, reporting on standardised templates, reliable image storage, regular skills maintenance, collaboration with a designated paediatric cardiologist, and regular scan audit/review. It was agreed that NoPE assessments should confidently exclude structural lesions at first scan. Practitioners would be expected to screen and establish gross normality of structure at first scan and obtain confirmation from paediatric cardiologist if required, and subsequently, functional echocardiography can be performed for haemodynamic assessment to guide management of newborn babies. To achieve training, NICHe group suggested that mandatory placements could be undertaken during core registrar training or neonatal subspecialty grid training with a paediatric cardiology placement for 6 months and a neonatology placement for a minimum of 6 months. In the future, we hope to define a precise curriculum for assessments. Technological advances may provide solutions-improvements in telemedicine may have neonatologists assessing haemodynamic status with paediatric cardiologists excluding structural lesions and neonatal echocardiography simulators could increase exposure to multiple pathologies and

  12. Comparing impedance cardiography and echocardiography in the assessment of reduced left ventricular systolic function

    DEFF Research Database (Denmark)

    Kaszuba, Elzbieta; Scheel, Sergej; Odeberg, Håkan

    2013-01-01

    An early and accurate diagnosis of chronic heart failure is a big challenge for a general practitioner. Assessment of left ventricular function is essential for the diagnosis of heart failure and the prognosis. A gold standard for identifying left ventricular function is echocardiography...

  13. Temporo-mandibular joint dislocation: an unusual complication of transoesophageal echocardiography.

    Science.gov (United States)

    Anantharam, Brijesh; Chahal, Navtej; Stephens, Nigel; Senior, Roxy

    2010-03-01

    Temporo-mandibular joint (TMJ) dislocation is an unusual complication of transoesophageal echocardiography (TEE). We report a rare case of bilateral TMJ dislocation in an 84-year-old man prior to DC cardioversion (DCCV) for atrial flutter. Shortly after TEE and DCCV, the patient complained of bilateral facial pain. An orthopantomogram revealed bilateral TMJ dislocation. A closed reduction was performed by maxillo-facial surgeons under intravenous anaesthesia. Although very uncommon, the physician should be aware of the complication and its management.

  14. The relevance of echocardiography heart measures for breeding against the risk of subaortic and pulmonic stenosis in Boxer dogs.

    Science.gov (United States)

    Menegazzo, L; Bussadori, C; Chiavegato, D; Quintavalla, C; Bonfatti, V; Guglielmini, C; Sturaro, E; Gallo, L; Carnier, P

    2012-02-01

    The aims of this study were to investigate the role and relative importance of auscultation and echocardiography traits as risk factors for the diagnosis of subaortic (SubAS) and pulmonic (PS) stenosis and to estimate the heritability (h(2)) of cardiac measurements taken through echocardiography for a random sample of Italian Boxer dogs. The data were cardiovascular examination results of 1,283 Italian Boxer dogs (686 females and 597 males) enrolled in the national screening program for heart defects arranged by the Italian Boxer Club. Examinations were performed during a 6-yr period by a group of 7 veterinary cardiologists following a standard protocol. Occurrence and severity of SubAS and PS were diagnosed, taking into account clinical and echocardiography findings such as the grade of cardiac murmur, direct ultrasound imaging of the anatomic obstructive lesions, and values of aortic or pulmonary blood flow velocities. A Bayesian logistic regression analysis was performed to identify clinical and echocardiography variables related to SubAS and PS diagnosis. Estimation of variance components for clinical and echocardiography traits was performed using a mixed linear animal model, Bayesian procedures, and the Gibbs sampler. Prevalence of SubAS (PS) was 8.4% (2.2) and 10.7% (6.4) for female and male dogs, respectively. Cardiac murmur, peak velocities, and annulus areas behaved as risk factors for SubAS and PS. The risk of a positive diagnosis for SubAS was 3 times greater for dogs with aortic annulus area dogs with areas >2.37 cm(2), 84 times greater for dogs showing aortic peak velocities >2.19 m/s relative to dogs with peak velocities dogs with moderate to severe murmur grades relative to dogs with absent murmur. Similar results were obtained for PS. The estimated h(2) for the occurrence of cardiac defects was 23.3% for SubAS and 8.6% for PS. Echocardiography and cardiac murmur grades exhibited moderate h(2) estimates and exploitable additive genetic variation

  15. Left Ventricular Deformation by Speckle Tracking Echocardiography at 2-year Follow-up in Treatment Naive Rheumatoid Arthritis Patients

    DEFF Research Database (Denmark)

    Løgstrup, Brian Bridal; Masic, D; Laurberg, Trine Bay

    2015-01-01

    -CCP titers were evaluated by standardized techniques at baseline and 2-year follow-up. We performed a novel advanced echocardiography by speckle tracking in means of global LV systolic deformation (GLS) imaging. One experienced senior rheumatologist and one experienced cardiologist performed all the clinical...... assessments as well as all the echocardiography including the LV deformation analysis at baseline and by 2-year follow-up. Results: Disease activity scores before treatment at baseline and at 2-year follow-up were respectively: number of swollen joints (28): 7.1+/-2.9 (SD) and 0.4+/-0.3, number of tender...

  16. Measurement of pulmonary arterial elastance in patients with systolic heart failure using Doppler echocardiography

    Science.gov (United States)

    Taghavi, Sepideh; Esmaeilzadeh, Maryam; Amin, Ahmad; Naderi, Nasim; Abkenar, Hooman Bakhshandeh; Maleki, Majid; Mitra, Chitsazan

    2016-01-01

    Objective: A reliable and easy-to-perform method for measuring right ventricular (RV) afterload is desirable when scheduling patients with systolic heart failure to undergo heart transplantation. The present study aimed to investigate the accuracy of echocardiographically-derived pulmonary arterial elastance as a measurement of pulmonary vascular resistance by comparing it with invasive measures. Methods: Thirty-one patients with moderate to severe systolic heart failure, including 22 (71%) male patients, with a mean age of 41.16±15.9 years were enrolled in the study. Right heart catheterization and comprehensive echocardiography during the first hour after completion of cardiac catheterization were performed in all the patients. The pulmonary artery elastance was estimated using the ratio of end-systolic pressure (Pes) over the stroke volume (SV) by both cardiac catheterization [Ea (PV)-C] and echocardiography [Ea (PV)-E]. Results: The mean Ea (PV)-C and Ea (PV)-E were estimated to be 0.73±0.49 mm Hg/mL and 0.67±0.44 mm Hg/mL, respectively. There was a significant relation between Ea (PV)-E and Ea (PV)-C (r=0.897, pechocardiography and catheterization methods for estimating Ea (PV), investigated by the Bland-Altman method, showed a mean bias of -0.06, with 95% limits of agreement from -0.36 mm Hg/mL to 0.48 mm Hg/mL. Conclusion: Doppler echocardiography is an easy, non-invasive, and inexpensive method for measuring pulmonary arterial elastance, which provides accurate and reliable estimation of RV afterload in patients with systolic heart failure. PMID:26467379

  17. The importance of echocardiography in transcatheter aortic valve implantation.

    Science.gov (United States)

    Bilen, Emine; Sari, Cenk; Durmaz, Tahir; Keleş, Telat; Bayram, Nihal A; Akçay, Murat; Ayhan, Hüseyin M; Bozkurt, Engin

    2014-01-01

    Valvular heart diseases cause serious health problems in Turkey as well as in Western countries. According to a study conducted in Turkey, aortic stenosis (AS) is second after mitral valve disease among all valvular heart diseases. AS is frequently observed in elderly patients who have several cardiovascular risk factors and comorbidities. In symptomatic severe AS, surgical aortic valve replacement (AVR) is a definitive treatment. However, in elderly patients with left ventricular dysfunction and comorbidities, the risk of operative morbidity and mortality increases and outweighs the gain obtained from AVR surgery. As a result, almost one-third of the patients with serious AS are considered ineligible for surgery. Transcatheter aortic valve implantation (TAVI) is an effective treatment in patients with symptomatic severe AS who have high risk for conventional surgery. Since being performed for the first time in 2002, with a procedure success rate reported as 95% and a mortality rate of 5%, TAVI has become a promising method. Assessment of vascular anatomy, aortic annular diameter, and left ventricular function may be useful for the appropriate selection of patients and may reduce the risk of complications. Cardiac imaging methods including 2D and 3D echocardiography and multidetector computed tomography are critical during the evaluation of suitable patients for TAVI as well as during and after the procedure. In this review, we describe the role of echocardiography methods in clinical practice for TAVI procedure in its entirety, i.e. from patient selection to guidance during the procedure, and subsequent monitoring. © 2013, Wiley Periodicals, Inc.

  18. Left ventricular ejection fraction and volumes as measured by 3D echocardiography and ultrafast computed tomography

    International Nuclear Information System (INIS)

    Vieira, Marcelo Luiz Campos; Nomura, Cesar H.; Tranchesi Junior, Bernardino; Oliveira, Wercules A. de; Naccarato, Gustavo; Serpa, Bruna S.; Passos, Rodrigo B.D.; Funari, Marcelo B. G.; Fischer, Claudio H.; Morhy, Samira S.

    2009-01-01

    Background: Real-time three-dimensional echocardiography (RT-3D-Echo) and ultrafast computed tomography (CT) are two novel methods for the analysis of LV ejection fraction and volumes. Objective: To compare LVEF and volume measurements as obtained using RT-3D-Echo and ultrafast CT. Methods: Thirty nine consecutive patients (27 men, mean age of 57+- 12 years) were studied using RT-3D-Echo and 64-slice ultrafast CT. LVEF and LV volumes were analyzed. Statistical analysis: coefficient of correlation (r: Pearson), Bland-Altman analysis, linear regression analysis, 95% CI, p 5 .58)%; end-diastolic volume ranged from 49.6 to 178.2 (87+-27.8) ml; end-systolic volume ranged from 11.4 to 78 (33.1+-13.6) ml. CT scan measurements: LVEF ranged from 53 to 86% (67.8+-7.78); end-diastolic volume ranged from 51 to 186 (106.5+-30.3) ml; end-systolic volume ranged from 7 to 72 (35.5+-13.4)ml. Correlations between RT-3D-Echo and CT were: LVEF (r: 0.7888, p<0.0001, 95% CI 0.6301 to 0.8843); end-diastolic volume (r: 0.7695, p<0.0001, 95% CI 0.5995 to 0.8730); end-systolic volume (r: 0.8119, p<0.0001, 95% CI 0.6673 to 0.8975). Conclusion: Good correlation between LVEF and ventricular volume parameters as measured by RT-3D-Echo and 64-slice ultrafast CT was found in the present case series. (author)

  19. A comparison of non-contrast and contrast-enhanced MRI in the initial stage of Legg-Calve-Perthes disease

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Harry K.W. [Texas Scottish Rite Hospital for Children, Center of Excellence in Hip Disorders, Dallas, TX (United States); University of Texas Southwestern, Department of Orthopedic Surgery, Dallas, TX (United States); Kaste, Sue [St. Jude Children' s Research Hospital, Department of Radiological Sciences, Memphis, TN (United States); St. Jude Children' s Research Hospital, Department of Oncology, Memphis, TN (United States); University of Tennessee School of Health Sciences, Department of Radiology, Memphis, TN (United States); Dempsey, Molly; Wilkes, David [Texas Scottish Rite Hospital for Children, Department of Radiology, Dallas, TX (United States)

    2013-09-15

    A prognostic indicator of outcome for Legg-Calve-Perthes disease (LCP) is needed to guide treatment decisions during the initial stage of the disease (stage 1), before deformity occurs. Radiographic prognosticators are applicable only after fragmentation (stage II). We investigated pre- and postcontrast MRI in depicting stage I femoral head involvement. Thirty children with stage I LCP underwent non-contrast coronal T1 fast spin-echo (FSE) and corresponding postcontrast fat-suppressed T1-weighted fast spin-echo (FSE) sequences to quantify the extent of femoral head involvement. Three pediatric radiologists and one pediatric orthopedic surgeon independently measured central head involvement. Interobserver reliability of percent head involvement using non-contrasted MR images had intraclass correlation coefficient (ICC) of 0.72. Postcontrast MRI improved interobserver reliability (ICC 0.82). Qualitatively, the area of involvement was more clearly visible on contrast-enhanced MRI. A comparison of results obtained by each observer using the two MRI techniques showed no correlation. ICC ranged from -0.08 to 0.03 for each observer. Generally, greater head involvement was depicted by contrast compared with non-contrast MRI (Pearson r = -0.37, P = 0.04). Pre- and postcontrast MRI assess two different components of stage I LCP. However, contrast-enhanced MRI more clearly depicts the area of involvement. (orig.)

  20. Non-vitamin K antagonist oral anticoagulants versus warfarin for the prevention of spontaneous echo-contrast and thrombus in patients with atrial fibrillation or flutter undergoing cardioversion: A trans-esophageal echocardiography study.

    Science.gov (United States)

    Kim, Yun Gi; Choi, Jong-Il; Kim, Mi-Na; Cho, Dong-Hyuk; Oh, Suk-Kyu; Kook, Hyungdon; Park, Hee-Soon; Lee, Kwang No; Baek, Yong-Soo; Roh, Seung-Young; Shim, Jaemin; Park, Seong-Mi; Shim, Wan Joo; Kim, Young-Hoon

    2018-01-01

    Spontaneous echo-contrast (SEC) and thrombus observed in trans-esophageal echocardiography (TEE) is known as a strong surrogate marker for future risk of ischemic stroke in patients with atrial fibrillation (AF) or atrial flutter (AFL). The efficacy of non-vitamin K antagonist oral anticoagulants (NOAC) compared to warfarin to prevent SEC or thrombus in patients with AF or AFL is currently unknown. AF or AFL patients who underwent direct current cardioversion (DCCV) and pre-DCCV TEE evaluation from January 2014 to October 2016 in a single center were analyzed. The prevalence of SEC and thrombus were compared between patients who received NOAC and those who took warfarin. NOAC included direct thrombin inhibitor and factor Xa inhibitors. Among 1,050 patients who were considered for DCCV, 424 patients anticoagulated with warfarin or NOAC underwent TEE prior to DCCV. Eighty patients who were anticoagulated for less than 21 days were excluded. Finally, 344 patients were included for the analysis (180 warfarin users vs. 164 NOAC users). No significant difference in the prevalence of SEC (44.4% vs. 43.9%; p = 0.919), dense SEC (13.9% vs. 15.2%; p = 0.722), or thrombus (2.2% vs. 4.3%; p = 0.281) was observed between the warfarin group and the NOAC group. In multivariate analysis, there was no association between NOAC and risk of SEC (odds ratio [OR]: 1.4, 95% CI: 0.796-2.297, p = 0.265) or thrombus (OR: 3.4, 95% CI: 0.726-16.039, p = 0.120). In conclusion, effectiveness of NOAC is comparable to warfarin in preventing SEC and thrombus in patients with AF or AFL undergoing DCCV. However, numerical increase in the prevalence of thrombus in NOAC group warrants further evaluation.