WorldWideScience

Sample records for contraband interrogation technology

  1. Basic concepts underlying fast-neutron-based contraband interrogation technology

    International Nuclear Information System (INIS)

    Fink, C.L.; Guenther, P.T.; Smith, D.L.

    1992-01-01

    All accelerator-based fast-neutron contraband interrogation systems have many closely interrelated subsystems, whose performance parameters will be critically interdependent. For optimal overall performance, a systems analysis design approach is required. This paper provides a general overview of the interrelationships and the tradeoffs to be considered for optimization of nonaccelerator subsystems

  2. Contraband detection with fast neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Buffler, Andy E-mail: abuffler@science.uct.ac.za

    2004-11-01

    Recent terror events and the increase in the trade of illicit drugs have fuelled the exploration of the use of fast neutrons as probes for the detection of hidden contraband, especially explosives, in packages ranging in size from small mail items to cargo containers. The various approaches using fast neutrons for contraband detection, presently under development, are reviewed. The role that a neutron system might play in the non-intrusive interrogation of airline luggage is discussed.

  3. Indian program for development of technologies relevant to reliable, non-intrusive, concealed-contraband detection

    International Nuclear Information System (INIS)

    Auluck, S.K.H.

    2007-01-01

    Generating capability for reliable, non-intrusive detection of concealed-contraband, particularly, organic contraband like explosives and narcotics, has become a national priority. This capability spans a spectrum of technologies. If a technology mission addressing the needs of a highly sophisticated technology like PFNA is set up, the capabilities acquired would be adequate to meet the requirements of many other sets of technologies. This forms the background of the Indian program for development of technologies relevant to reliable, non-intrusive, concealed contraband detection. One of the central themes of the technology development programs would be modularization of the neutron source and detector technologies, so that common elements can be combined in different ways for meeting a variety of application requirements. (author)

  4. Contraband detection technological complex with ion linac

    International Nuclear Information System (INIS)

    Gavrish, Yu.N.; Svistunov, Yu.A.; Sidorov, A.V.

    2004-01-01

    The contraband detection technological complex (CDTC) to detect explosives, fission materials, and vegetable drugs is proposed. Our approach employs the pulsed neutron source. The CDTC employs the rf linac to provide a beam of deuterons of 1 or 3.5 MeV, which impinge upon a target giving birth pulsed neutron flow. Explosives are identified by the matrix detection system with gamma registration under interaction of neutron on N, O, C nuclei. Experimental verification of main principles of matrix detection system is presented

  5. Managed access technology to combat contraband cell phones in prison: Findings from a process evaluation.

    Science.gov (United States)

    Grommon, Eric

    2018-02-01

    Cell phones in correctional facilities have emerged as one of the most pervasive forms of modern contraband. This issue has been identified as a top priority for many correctional administrators in the United States. Managed access, a technology that utilizes cellular signals to capture transmissions from contraband phones, has received notable attention as a promising tool to combat this problem. However, this technology has received little evaluative attention. The present study offers a foundational process evaluation and draws upon output measures and stakeholder interviews to identify salient operational challenges and subsequent lessons learned about implementing and maintaining a managed access system. Findings suggest that while managed access captures large volumes of contraband cellular transmissions, the technology requires significant implementation planning, personnel support, and complex partnerships with commercial cellular carriers. Lessons learned provide guidance for practitioners to navigate these challenges and for scholars to improve future evaluations of managed access. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Contraband Detection with Nuclear Resonance Fluorescence: Feasibility and Impact

    International Nuclear Information System (INIS)

    Pruet, J; Lange, D

    2007-01-01

    In this report they show that cargo interrogation systems developed to thwart trafficking of illicit nuclear materials could also be powerful tools in the larger fight against contraband smuggling. In particular, in addition to detecting special nuclear materials, cargo scanning systems that exploit nuclear resonance fluorescence to detect specific isotopes can be used to help find: chemical weapons; some drugs as well as some chemicals regulated under the controlled substances act; precious metals; materials regulated under export control laws; and commonly trafficked fluorocarbons

  7. Contraband detection

    International Nuclear Information System (INIS)

    Gozzani, T.

    1995-01-01

    Inspecting incoming cargo for drugs, explosives and other contraband would quickly overwhelm inspection agencies even if a small percentage of the cargoes were manually searched. Now a new accelerator-based inspection system using pulsed fast neutron analysis (PFNA) allows automated inspection of loaded cargo containers and trucks. A collimated pulsed beam of fast neutrons, scanned over the side of a cargo container as it passes, excites the nuclei of common elements in bulk materials. The primary signals of interest for contraband are gammaray emissions following inelastic scattering of the fast neutrons from carbon and oxygen. Direct imaging of the contents of the material by time-of-flight analysis identifies the position of the interactions, while gamma-ray spectroscopy identifies the elemental gamma rays. The ratio of elements or other combinations of the elemental signatures are used to identify contraband - a high carbon-to-oxygen ratio, for example, is characteristic of drugs. The system incorporates gamma ray detectors, and analogue and digital processors sort the pulses for position and elemental information. Detection algorithms produce three-dimensional images of possible concealed contraband. From these images the inspector can identify suspicious objects within the cargo container

  8. Contraband detection

    Energy Technology Data Exchange (ETDEWEB)

    Gozzani, T. [Science Applications International Corporation, Santa Clara (United States)

    1995-07-15

    Inspecting incoming cargo for drugs, explosives and other contraband would quickly overwhelm inspection agencies even if a small percentage of the cargoes were manually searched. Now a new accelerator-based inspection system using pulsed fast neutron analysis (PFNA) allows automated inspection of loaded cargo containers and trucks. A collimated pulsed beam of fast neutrons, scanned over the side of a cargo container as it passes, excites the nuclei of common elements in bulk materials. The primary signals of interest for contraband are gammaray emissions following inelastic scattering of the fast neutrons from carbon and oxygen. Direct imaging of the contents of the material by time-of-flight analysis identifies the position of the interactions, while gamma-ray spectroscopy identifies the elemental gamma rays. The ratio of elements or other combinations of the elemental signatures are used to identify contraband - a high carbon-to-oxygen ratio, for example, is characteristic of drugs. The system incorporates gamma ray detectors, and analogue and digital processors sort the pulses for position and elemental information. Detection algorithms produce three-dimensional images of possible concealed contraband. From these images the inspector can identify suspicious objects within the cargo container.

  9. Accelerator requirements for fast-neutron interrogation of luggage and cargo

    International Nuclear Information System (INIS)

    Micklich, B.J.; Fink, C.L.; Yule, T.J.

    1995-01-01

    Several different fast-neutron based techniques are being studied for the detection of contraband substances in luggage and cargo containers. The present work discusses the accelerator requirements for fast-neutron transmission spectroscopy (FNTS), pulsed fast-neutron analysis (PFNA), and 14-MeV neutron interrogation. These requirements are based on the results of Monte-Carlo simulations of neutron or gamma detection rates. Accelerator requirements are driven by count-rate considerations, spatial resolution and acceptable uncertainties in elemental compositions. The authors have limited their analyses to luggage inspection with FNTS and to cargo inspection with PFNA or 14-MeV neutron interrogation

  10. Summary tables of six commercially available entry control and contraband detection technologies

    International Nuclear Information System (INIS)

    Hunter, John Anthony

    2005-01-01

    Existing contraband detection and entry control devices such as metal detectors, X-ray machines, and radiation monitors were investigated for their capability to operate in an automated environment. In addition, a limited number of new devices for detection of explosives, chemicals, and biological agents were investigated for their feasibility for inclusion in future physical security systems. The tables in this document resulted from this investigation, which was part of a conceptual design upgrade for the United States Mints. This summary of commercially available technologies was written to provide a reference for physical security upgrades at other sites

  11. Accelerator based techniques for contraband detection

    Science.gov (United States)

    Vourvopoulos, George

    1994-05-01

    It has been shown that narcotics, explosives, and other contraband materials, contain various chemical elements such as H, C, N, O, P, S, and Cl in quantities and ratios that differentiate them from each other and from other innocuous substances. Neutrons and γ-rays have the ability to penetrate through various materials at large depths. They are thus able, in a non-intrusive way, to interrogate volumes ranging from suitcases to Sea-Land containers, and have the ability to image the object with an appreciable degree of reliability. Neutron induced reactions such as (n, γ), (n, n') (n, p) or proton induced γ-resonance absorption are some of the reactions currently investigated for the identification of the chemical elements mentioned above. Various DC and pulsed techniques are discussed and their advantages, characteristics, and current progress are shown. Areas where use of these methods is currently under evaluation are detection of hidden explosives, illicit drug interdiction, chemical war agents identification, nuclear waste assay, nuclear weapons destruction and others.

  12. 78 FR 76860 - Contraband Screening for Criminal Justice Applications

    Science.gov (United States)

    2013-12-19

    ... for the detection of contraband. Screening technology is widely used by criminal justice practitioners...: 1. Model Number and Name of the screening system/device. 2. Technology used by the system/device for... container or bag), Plastic, Wood, Ceramic, Powder (in a small packet), and/or Paper (e.g., folded currency...

  13. The nuclear materials contraband

    International Nuclear Information System (INIS)

    Williams, P.; Woessner, P.

    1996-01-01

    Several seizures of nuclear materials carried by contraband have been achieved. Some countries or criminal organizations could manufacture atomic bombs and use them. This alarming situation is described into details. Only 40% of drugs are seized by the American police and probably less in western Europe. The nuclear materials market is smaller than the drugs'one but the customs has also less experience to intercept the uranium dispatch for instance more especially as the peddlers are well organized. A severe control of the international transports would certainly allow to seize a large part of nuclear contraband materials but some dangerous isotopes as uranium 235 or plutonium 239 are little radioactive and which prevents their detection by the Geiger-Mueller counters. In France, some regulations allow to control the materials used to manufacture the nuclear weapons, and diminish thus the risk of a nuclear materials contraband. (O.L.). 4 refs., 2 figs

  14. New Non-Intrusive Inspection Technologies for Nuclear Security and Nonproliferation

    Science.gov (United States)

    Ledoux, Robert J.

    2015-10-01

    Comprehensive monitoring of the supply chain for nuclear materials has historically been hampered by non-intrusive inspection systems that have such large false alarm rates that they are impractical in the flow of commerce. Passport Systems, Inc. (Passport) has developed an active interrogation system which detects fissionable material, high Z material, and other contraband in land, sea and air cargo. Passport's design utilizes several detection modalities including high resolution imaging, passive radiation detection, effective-Z (EZ-3D™) anomaly detection, Prompt Neutrons from Photofission (PNPF), and Nuclear Resonance Fluorescence (NRF) isotopic identification. These technologies combine to: detect fissionable, high-Z, radioactive and contraband materials, differentiate fissionable materials from high-Z shielding materials, and isotopically identify actinides, Special Nuclear Materials (SNM), and other contraband (e.g. explosives, drugs, nerve agents). Passport's system generates a 3-D image of the scanned object which contains information such as effective-Z and density, as well as a 2-D image and isotopic and fissionable information for regions of interest.

  15. System to detect contraband in cargo containers using fast and slow neutron irradiation and collimated gamma detectors

    International Nuclear Information System (INIS)

    Smith, R.C.; Hurwitz, M.J.; Tran, K.C.

    1995-01-01

    We have produced a product design concept for an automatic, shipping-container inspection system to be used for detection of contraband, including illicit drugs, and for trade regulation enforcement via shipping manifest confirmation. Using nondestructive nuclear techniques the system can see deeply into the cargo and generate a 3-D spatial image of an entire container's contents automatically and in real time. A pulsed, sealed-tube, neutron generator is employed. The approach divides a container into numerous, small, volume elements that are individually interrogated using concurrent fast and slow neutron activation and gamma detection by collimated scintillators. We have designed, built, and operated a laboratory apparatus which has demonstrated the attractiveness of this approach. Experimental data were found to agree with design expectations derived from computer modeling. By combining selected element signatures and phenomenological measures, together with discrimination algorithms, we have demonstrated that a full-scale inspection system would need from less than 5 min to 30 min (depending on cargo type) to process an 8 ftx8 ftx40 ft container in order to detect hidden contraband. (orig.)

  16. Using contraband simulators for portal metal detector testing

    Energy Technology Data Exchange (ETDEWEB)

    Murray, D.W.

    1992-08-01

    Because contraband materials or items are either too dangerous or too expensive, contraband simulators have been widely used to test contraband detection equipment. Very realistic bomb simulators have been used to test x-ray scanners, and common radioactive sources have been used successfully to test the operation of special nuclear material (SNM) radiation detectors. The simulators used to test early metal detectors were also reasonably successful; however, these simulators were rapidly outdated by the introduction of modern active field metal detectors. This paper describes some of the earlier attempts to develop metal detector test simulators. A successful highly enriched uranium (HEU) simulator for metal detector testing is described that has duplicated all the characteristics modern equipment is capable of detecting. The paper also describes the development needed to produce handgun simulators that could be used effectively for metal detector performance testing.

  17. Using contraband simulators for portal metal detector testing

    Energy Technology Data Exchange (ETDEWEB)

    Murray, D.W.

    1992-01-01

    Because contraband materials or items are either too dangerous or too expensive, contraband simulators have been widely used to test contraband detection equipment. Very realistic bomb simulators have been used to test x-ray scanners, and common radioactive sources have been used successfully to test the operation of special nuclear material (SNM) radiation detectors. The simulators used to test early metal detectors were also reasonably successful; however, these simulators were rapidly outdated by the introduction of modern active field metal detectors. This paper describes some of the earlier attempts to develop metal detector test simulators. A successful highly enriched uranium (HEU) simulator for metal detector testing is described that has duplicated all the characteristics modern equipment is capable of detecting. The paper also describes the development needed to produce handgun simulators that could be used effectively for metal detector performance testing.

  18. Factors associated with different cigarette access behaviours among underage smoking youth who usually smoke contraband (native) cigarettes.

    Science.gov (United States)

    Leatherdale, Scott T; Ahmed, Rashid; Vu, Mary

    2011-01-01

    Given that little is known about how youth access contraband cigarettes, the current study seeks to examine factors associated with how underage smoking youth report usually accessing contraband cigarettes. This study used nationally representative data collected from 41,886 students (grades 9 to 12) as part of the 2006-07 Canadian Youth Smoking Survey (YSS). Using data from current smokers who report that their usual brand of cigarettes is contraband, three logistic regression models were used to examine factors associated with buying cigarettes from a store, getting cigarettes from a family member, or getting cigarettes from friends or strangers. In 2006, 7.9% (n = 1 3,300) of Canadian youth who were current smokers reported that their usual brand of cigarettes was contraband. Among these youth, the majority reported that they usually get their cigarettes from a friend or stranger (54.8%), whereas 26.4% report usually getting them from a family member and 18.8% usually buying their own from a store. Boys were more likely to buy contraband cigarettes from a store, whereas youth with a parent who smokes contraband cigarettes were substantially more likely to get contraband cigarettes from a family member and youth with friends who smoke contraband cigarettes were substantially more likely to get contraband cigarettes from a friend or stranger. Ongoing surveillance of contraband cigarette use among youth and how youth access contraband cigarettes is required for guiding future tobacco control policy and programming activities.

  19. Contraband, free ports, and British merchants in the Caribbean world, 1739-1772

    Directory of Open Access Journals (Sweden)

    Nadine Hunt

    2013-04-01

    Full Text Available This article examines the evolution of contraband to legitimate trade in the eighteenth century Caribbean world during the War of Jenkins’ Ear and Seven Years’ War. It focuses on the informal networks of the British South Sea Company and the trade of informal actors. The article explores how British legislators shifted Jamaican and Dominican colonial economies away from contraband trade by opening free ports in 1766. The British Parliament passed the Free Port Act of Jamaica and Dominica following Danish and Dutch colonial efforts to crack down on contraband trade in the Caribbean world. This transition from contraband to legitimate trade enabled British merchants to engage in free trade by importing and exporting an assortment of commodities and enslaved people to and from Jamaica to other colonies in the Caribbean world.

  20. A new proof-of-principle contraband detection system

    International Nuclear Information System (INIS)

    Sredniawski, J.J.; Debiak, T.; Kamykowski, E.

    1995-12-01

    An accelerator-based technique is being developed to detect contraband materials in large containers. The source, which uses a low-energy proton beam to generate high-energy gamma rays, uses the gamma resonance absorption technique to detect nitrogen-14 and chlorine-35 in containers. Both these materials are commonly found in contraband drugs as well as in explosives. Through the use of segmented BGO detectors to detect the resonant gamma rays a quantity as low as ∼ 1 kg can be located with a considerable degree of confidence. Several stations at a port of entry can be operated with one accelerator, as described

  1. Liquid contrabands classification based on energy dispersive X-ray diffraction and hybrid discriminant analysis

    International Nuclear Information System (INIS)

    YangDai, Tianyi; Zhang, Li

    2016-01-01

    Energy dispersive X-ray diffraction (EDXRD) combined with hybrid discriminant analysis (HDA) has been utilized for classifying the liquid materials for the first time. The XRD spectra of 37 kinds of liquid contrabands and daily supplies were obtained using an EDXRD test bed facility. The unique spectra of different samples reveal XRD's capability to distinguish liquid contrabands from daily supplies. In order to create a system to detect liquid contrabands, the diffraction spectra were subjected to HDA which is the combination of principal components analysis (PCA) and linear discriminant analysis (LDA). Experiments based on the leave-one-out method demonstrate that HDA is a practical method with higher classification accuracy and lower noise sensitivity than the other methods in this application. The study shows the great capability and potential of the combination of XRD and HDA for liquid contrabands classification.

  2. Liquid contrabands classification based on energy dispersive X-ray diffraction and hybrid discriminant analysis

    Energy Technology Data Exchange (ETDEWEB)

    YangDai, Tianyi [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education (China); Zhang, Li, E-mail: zhangli@nuctech.com [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education (China)

    2016-02-01

    Energy dispersive X-ray diffraction (EDXRD) combined with hybrid discriminant analysis (HDA) has been utilized for classifying the liquid materials for the first time. The XRD spectra of 37 kinds of liquid contrabands and daily supplies were obtained using an EDXRD test bed facility. The unique spectra of different samples reveal XRD's capability to distinguish liquid contrabands from daily supplies. In order to create a system to detect liquid contrabands, the diffraction spectra were subjected to HDA which is the combination of principal components analysis (PCA) and linear discriminant analysis (LDA). Experiments based on the leave-one-out method demonstrate that HDA is a practical method with higher classification accuracy and lower noise sensitivity than the other methods in this application. The study shows the great capability and potential of the combination of XRD and HDA for liquid contrabands classification.

  3. Liquid contrabands classification based on energy dispersive X-ray diffraction and hybrid discriminant analysis

    Science.gov (United States)

    YangDai, Tianyi; Zhang, Li

    2016-02-01

    Energy dispersive X-ray diffraction (EDXRD) combined with hybrid discriminant analysis (HDA) has been utilized for classifying the liquid materials for the first time. The XRD spectra of 37 kinds of liquid contrabands and daily supplies were obtained using an EDXRD test bed facility. The unique spectra of different samples reveal XRD's capability to distinguish liquid contrabands from daily supplies. In order to create a system to detect liquid contrabands, the diffraction spectra were subjected to HDA which is the combination of principal components analysis (PCA) and linear discriminant analysis (LDA). Experiments based on the leave-one-out method demonstrate that HDA is a practical method with higher classification accuracy and lower noise sensitivity than the other methods in this application. The study shows the great capability and potential of the combination of XRD and HDA for liquid contrabands classification.

  4. A contraband detection system proof-of-principle device using electrostatic acceleration

    International Nuclear Information System (INIS)

    Sredniawski, Joseph J.; Debiak, T.W.; Kamykowski, E.; Rathke, J.; Milton, B.; Rogers, J.; Schmor, P.; Stanford, G.; Brando, J.

    1996-01-01

    A new Contraband Detection System (CDS) Proof-of- Principle (POP) device is nearing completion at Northrop Grumman's Advanced Technology and Development Center. We employ gamma resonance absorption (GRA) to detect nitrogen or chlorine in explosives and certain forms of illegal drugs. Using tomography, 3-D images of the total density and selected element density are generated. These characteristics together may be utilized with considerable confidence in determining if contraband is present in baggage or cargo. The CDS employs a high current (10 mA) DC electrostatic accelerator that provides a beam of protons at either 1.75 or 1.89 MeV. These high energy particles impinge upon a target coated with 13 C or 34 S. The resultant resonant gamma rays are preferentially absorbed in either 14 N or 35 Cl. Because of the penetrating power of the gamma rays, this approach can be utilized for inspection of fully loaded aircraft containers such as the LD3. Our current program calls for testing of the POP CDS by late 1996. This paper presents the overall design and characteristics of the CDS POP. (author)

  5. Gamma-resonance Contraband Detection using a high current tandem accelerator

    International Nuclear Information System (INIS)

    Milton, B. F.; Beis, J.; Dale, D.; Rogers, J.; Ruegg, R.; Debiak, T.; Kamykowski, E.; Melnychuk, S.; Rathke, J.; Sredniawski, J.

    1999-01-01

    TRIUMF and Northrop Grumman have developed a new system for the detection of concealed explosives and drugs. This Contraband Detection System (CDS) is based on the resonant absorption by 14 N of gammas produced using 13 C(p,γ) 14 N. The chosen reaction uses protons at 1.75 MeV and the gammas have an energy of 9.17 MeV. By measuring both the resonant and the non-resonant absorption using detectors with good spatial resolution, and applying standard tomographic techniques, we are able to produce 3D images of both the nitrogen partial density and the total density. The images together may be utilized with considerable confidence to determine if small amounts of nitrogen based explosives, heroin or cocaine are present in the interrogated containers. Practical Gamma Resonant Absorption (GRA) scanning requires an intense source of protons. However this proton source must also be very stable, have low energy spread, and have good spatial definition. These demands suggested a tandem as the accelerator of choice. We have therefore constructed a 2 MeV H - tandem optimized for high current (10 mA) operation, while minimizing the overall size of the accelerator. This has required several special innovations which will be presented in the paper. We will also present initial commissioning results

  6. Bayesian Processing for the Detection of Radioactive Contraband from Uncertain Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Candy, J V; Sale, K; Guidry, B; Breitfeller, E; Manatt, D; Chambers, D

    2007-06-26

    With the increase in terrorist activities throughout the world, the need to develop techniques capable of detecting radioactive contraband in a timely manner is a critical requirement. The development of Bayesian processors for the detection of contraband stems from the fact that the posterior distribution is clearly multimodal eliminating the usual Gaussian-based processors. The development of a sequential bootstrap processor for this problem is discussed and shown how it is capable of providing an enhanced signal for eventual detection.

  7. Design and characterisation of a pulsed neutron interrogation facility

    International Nuclear Information System (INIS)

    Favalli, A.; Pedersen, B.

    2007-01-01

    The Joint Research Centre recently obtained a license to operate a new experimental device intended for research in the field of nuclear safeguards. The research projects currently being planned for the new device includes mass determination of fissile materials in matrices and detection of contraband non-nuclear materials. The device incorporates a commercial pulsed neutron generator and a large graphite mantle surrounding the sample cavity. In this configuration, a relatively high thermal neutron flux with a long lifetime is achieved inside the sample cavity. By pulsing the neutron generator, a sample may be interrogated by a pure thermal neutron flux during repeated time periods. The paper reports on the design of the new device and the pulsed fast and thermal neutron source. The thermal neutron flux caused by the neutron generator and the graphite structure has been characterised by foil activation, fission chamber and 3 He proportional counter measurements. (authors)

  8. Apparatus and method for detecting contraband using fast neutron activation

    International Nuclear Information System (INIS)

    Gozani, T.; Sawa, Z.P.; Shea, P.M.

    1992-01-01

    This patent describes a method of detecting contraband within an object under investigation. It comprises: generating a beam of case neutrons; irradiating the object with the beam of fast neutrons, the fast neutrons interacting with atomic nuclei of the elements contained within the object to produce a gamma-ray spectrum having spectral lines characteristic of the elements contained within the object; measuring the spectral lines of the gamma-ray spectrum using a multiplicity of gamma-ray detectors judiciously positioned around the object; detecting the number of neutrons that pass through the object without interacting substantially with atomic nuclei within the object; determining the spatial and density distributions of the atomic nuclei of the elements contained within the object from the measured gamma-ray spectrum obtained from the multiplicity of gamma-ray detectors and the number of neutrons that pass through the object; comparing the measured spatial and density distributions of the atomic nuclei of the elements within the object with known spatial and density distributions of atomic nuclei for elements characteristic of contraband; and determining that contraband is present within the object when the comparison indicates a substantial match

  9. Novel applications of fast neutron interrogation methods

    International Nuclear Information System (INIS)

    Gozani, Tsahi

    1994-01-01

    The development of non-intrusive inspection methods for contraband consisting primarily of carbon, nitrogen, oxygen, and hydrogen requires the use of fast neutrons. While most elements can be sufficiently well detected by the thermal neutron capture process, some important ones, e.g., carbon and in particular oxygen, cannot be detected by this process. Fortunately, fast neutrons, with energies above the threshold for inelastic scattering, stimulate relatively strong and specific gamma ray lines from these elements. The main lines are: 6.13 for O, 4.43 for C, and 5.11, 2.31 and 1.64 MeV for N. Accelerator-generated neutrons in the energy range of 7 to 15 MeV are being considered as interrogating radiations in a variety of non-intrusive inspection systems for contraband, from explosives to drugs and from coal to smuggled, dutiable goods. In some applications, mostly for inspection of small items such as luggage, the decision process involves a rudimentary imaging, akin to emission tomography, to obtain the localized concentration of various elements. This technique is called FNA - Fast Neutron Analysis. While this approach offers improvements over the TNA (Thermal Neutron Analysis), it is not applicable to large objects such as shipping containers and trucks. For these challenging applications, a collimated beam of neutrons is rastered along the height of the moving object. In addition, the neutrons are generated in very narrow nanosecond pulses. The point of their interaction inside the object is determined by the time of flight (TOF) method, that is measuring the time elapsed from the neutron generation to the time of detection of the stimulated gamma rays. This technique, called PFNA (Pulsed Fast Neutron Analysis), thus directly provides the elemental, and by inference, the chemical composition of the material at every volume element (voxel) of the object. The various neutron-based techniques are briefly described below. ((orig.))

  10. The development of enabling technologies for producing active interrogation beams.

    Science.gov (United States)

    Kwan, Thomas J T; Morgado, Richard E; Wang, Tai-Sen F; Vodolaga, B; Terekhin, V; Onischenko, L M; Vorozhtsov, S B; Samsonov, E V; Vorozhtsov, A S; Alenitsky, Yu G; Perpelkin, E E; Glazov, A A; Novikov, D L; Parkhomchuk, V; Reva, V; Vostrikov, V; Mashinin, V A; Fedotov, S N; Minayev, S A

    2010-10-01

    A U.S./Russian collaboration of accelerator scientists was directed to the development of high averaged-current (∼1 mA) and high-quality (emittance ∼15 πmm mrad; energy spread ∼0.1%) 1.75 MeV proton beams to produce active interrogation beams that could be applied to counterterrorism. Several accelerator technologies were investigated. These included an electrostatic tandem accelerator of novel design, a compact cyclotron, and a storage ring with energy compensation and electron cooling. Production targets capable of withstanding the beam power levels were designed, fabricated, and tested. The cyclotron/storage-ring system was theoretically studied and computationally designed, and the electrostatic vacuum tandem accelerator at BINP was demonstrated for its potential in active interrogation of explosives and special nuclear materials.

  11. Safeguards applications of far infrared radiometric techniques for the detection of contraband

    International Nuclear Information System (INIS)

    Hodges, D.T.; Reber, E.E.; Foote, F.B.; Schellenbaum, R.L.

    1980-02-01

    A new safeguards system under development employs radiometers in the 100 to 300 GHz spectral band to detect contraband, including shielding materials (used to attenuate the gamma ray emissions from nuclear materials), weapons, or explosives covertly concealed on personnel. Clothing is highly transparent at these frequencies and imaging techniques can detect contraband by its emissivity and reflectivity differences relative to human tissues. Experimental data are presented and sample images are used as a basis to discuss system advantages and limitations

  12. Safeguards applications of far infrared radiometric techniques for the detection of contraband

    Energy Technology Data Exchange (ETDEWEB)

    Hodges, D.T.; Reber, E.E.; Foote, F.B.; Schellenbaum, R.L.

    1980-02-01

    A new safeguards system under development employs radiometers in the 100 to 300 GHz spectral band to detect contraband, including shielding materials (used to attenuate the gamma ray emissions from nuclear materials), weapons, or explosives covertly concealed on personnel. Clothing is highly transparent at these frequencies and imaging techniques can detect contraband by its emissivity and reflectivity differences relative to human tissues. Experimental data are presented and sample images are used as a basis to discuss system advantages and limitations.

  13. Statistical Requirements For Pass-Fail Testing Of Contraband Detection Systems

    International Nuclear Information System (INIS)

    Gilliam, David M.

    2011-01-01

    Contraband detection systems for homeland security applications are typically tested for probability of detection (PD) and probability of false alarm (PFA) using pass-fail testing protocols. Test protocols usually require specified values for PD and PFA to be demonstrated at a specified level of statistical confidence CL. Based on a recent more theoretical treatment of this subject [1], this summary reviews the definition of CL and provides formulas and spreadsheet functions for constructing tables of general test requirements and for determining the minimum number of tests required. The formulas and tables in this article may be generally applied to many other applications of pass-fail testing, in addition to testing of contraband detection systems.

  14. 28 CFR 553.13 - Procedures for handling contraband.

    Science.gov (United States)

    2010-07-01

    ... purchase, or as a gift) without staff authorization may be considered nuisance contraband for which a claim of ownership is ordinarily not accepted. (iii) If the inmate establishes ownership, but the item is... evidence of ownership of the listed items. A claim of ownership may not be accepted for an item made from...

  15. Techniques for detecting explosives and contraband

    International Nuclear Information System (INIS)

    Vourvopoulos, G.

    1994-01-01

    Because terrorism continues to be a societal threat, scientists are still searching for ways to identify concealed weapons that can be used in terrorist attacks. Explosives are singled out for particular attention because they can easily be shaped to look innocuous, and are still hard to detect. At present, there are three methods under development for the detection of explosives: X-ray imaging, vapour detection and nuclear techniques, and this article will concentrate on the latter. Since there is no single technology that can address all the questions concerning the detection of explosives and other illicit contraband, the philosophy that emerges is that of an integral system combining methodologies. Such a system could contain a nuclear technology device, a vapour detector, and an X-ray imaging device, all backed by an intelligence gathering system. In this paper methods are suggested for identifying explosives which may be used in terrorist attacks and for detecting concealed drugs. Techniques discussed are X-ray imaging, combining high and low energy x-ray machines, vapour detection using a ''sniffer'' to collect vapour samples then analysing the vapour by gas chromatography, chemiluminescence and mass spectroscopy and nuclear techniques. Nuclear techniques, such as neutron activation analysis, are discussed in detail but it is stressed that they need to be carried out at speed to eliminate disruption and delay at airports etc. (UK)

  16. Technology for Polymer Optical Fiber Bragg Grating Fabrication and Interrogation

    DEFF Research Database (Denmark)

    Ganziy, Denis

    The aim of this project is to develop a new, high-quality interrogator for FBG sensor systems, which combines high performance with costeffectiveness. The work includes the fields of optical system design, signal processing, and algorithm investigation. We present an efficient and fast peak...... analyze and investigate errors and drawbacks, which are typical for spectrometer-based interrogators: undersampling, grating internal reflection, photo response nonuniformity, pixel crosstalk and temperature and long term drift. We propose a novel type of multichannel Digital Micromirror Device (DMD......) based interrogator, where the linear detector is replaced with a commercially available DMD, which leads to cost reduction and better performance. Original optical design, which utilizes advantages of a retro-reflect optical scheme, has been developed in Zemax. We test the presented interrogator...

  17. Design and Construction of a First Prototype Muon Tomography System with GEM Detectors for the Detection of Nuclear Contraband

    CERN Document Server

    AUTHOR|(CDS)2074269; Grasso, L; Locke, J B; Quintero, A; Mitra, D

    2009-01-01

    Current radiation portal monitors at sea ports and international borders that employ standard radiation detection techniques are not very sensitive to nuclear contraband that is well shielded to absorb emanating radiation. Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing cargo or vehicles that contain high-Z material is a promising passive interrogation technique for solving this problem. We report on the design and construction of compact Micro-Pattern Gas Detectors for a small prototype MT station. This station will employ 10 tracking stations based on 30cm x 30cm low-mass triple-GEM detectors with 2D readout. Due to the excellent spatial resolution of GEMs it is sufficient to use a gap of only a few cm between tracking stations. Together with the compact size of the GEM detectors this allows the GEM MT station to be an order of magnitude more compact than MT stations using traditional drift tubes. We present details of the production and assemb...

  18. Complicity in contraband: British American Tobacco and cigarette smuggling in Asia.

    Science.gov (United States)

    Collin, J; Legresley, E; MacKenzie, R; Lawrence, S; Lee, K

    2004-12-01

    To examine the complicity of British American Tobacco (BAT) in cigarette smuggling in Asia, and to assess the centrality of illicit trade to regional corporate strategy. Analysis of previously confidential documents from BAT's Guildford depository. An iterative strategy combined searches based on geography, organisational structure, and key personnel, while corporate euphemisms for contraband were identified by triangulation. BAT documents demonstrate the strategic importance of smuggling across global, regional, national, and local levels. Particularly important in Asia, contraband enabled access to closed markets, created pressure for market opening, and was highly profitable. Documents demonstrate BAT's detailed oversight of illicit trade, seeking to reconcile the conflicting demands of control and deniability. BAT documents demonstrate that smuggling has been driven by corporate objectives, indicate national measures by which the problem can be addressed, and highlight the importance of a coordinated global response via WHO's Framework Convention on Tobacco Control.

  19. APSTNG: Neutron interrogation for detection of explosives and drugs and nuclear and CW materials

    International Nuclear Information System (INIS)

    Rhodes, E.; Peters, C.W.

    1993-01-01

    A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed-portal requirements for nondestructive detection, including monitoring of contraband explosives, drugs, and weapon materials, and treaty verification of sealed munitions. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutron generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron reactions identify nuclides associated with all major chemicals in explosives, drugs, and chemical warfare agents, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from detection times of the gamma rays and alpha-particles yield a separate coarse tomographic image of each identified nuclide. The APSTNG also forms the basis for a compact fast-neutron transmission imaging system that can be used along with or instead of the emission imaging system. Proof-of-concept experiments have been performed under laboratory conditions for simulated nuclear and chemical warfare munitions and for explosives and drugs. The small and relatively inexpensive APSTNG exhibits high reliability and can be quickly replaced. Surveillance systems based on APSTNG technology can avoid the large physical size, high capital and operating expenses, and reliability problems associated with complex accelerators

  20. Contraband detection using high-energy gamma rays from 16O*

    International Nuclear Information System (INIS)

    Micklich, B.J.; Fink, C.L.; Sagalovsky, L.; Smith, D.L.

    1996-01-01

    High-energy monoenergetic gamma rays (6.13 and 7.12 MeV) from the decay of excited states of the 16 O* nucleus are highly penetrating and thus offer potential for non-intrusive inspection of loaded containers for narcotics, explosives, and other contraband items. These excited states can be produced by irradiation of water with 14-MeV neutrons from a DT neutron generator or through the 19 F(p,α) 16 O* reaction. Resonances in 19 F(p,α) 16 O* at proton energies between 340 keV and 2 MeV allow use of a low-energy accelerator to provide a compact, portable gamma source of reasonable intensity. The present work provides estimates of gamma source parameters and suggests how various types of contraband could be detected. Gamma rays can be used to perform transmission or emission radiography of containers or other objects. Through the use of (γ, n) and (γ, fission) reactions, this technique is also capable of detecting special nuclear materials such as deuterium, lithium, beryllium, uranium, and plutonium. Analytic and Monte Carlo techniques are used to model empty and loaded container inspection for accelerator-produced gamma, radioisotope, and x-ray sources

  1. Atrial fibrillation in a healthy adolescent after heavy smoking of contraband cigarettes.

    Science.gov (United States)

    Ozyilmaz, Isa; Ozyilmaz, Sinem; Tosun, Oyku; Tola, Hasan Tahsin; Saygi, Murat; Ergul, Yakup

    2015-08-01

    The use of contraband cigarettes is a serious public health problem. We present a case of atrial fibrillation in a healthy adolescent suspected to be caused by smoking contraband cigarettes. A 15-year-old man was admitted to our emergency department experiencing syncope and palpitations. He was a cigarette smoker, but he had never smoked any illicit tobacco products before. He had finished a pack of counterfeit cigarettes (20 pieces) in 1.5 h. His electrocardiogram showed atrial fibrillation with a rapid ventricular response and irregular RR intervals. The patient had no history of alcohol use, surgery, palpitations, hypertension, chronic bronchitis, or any infectious diseases. His atrial fibrillation was converted to a normal sinus rhythm after the cardioversion treatment. Our patient was discharged from the pediatric cardiology service and advised to quit smoking cigarettes, strictly warning against illicit tobacco products. In conclusion, intensive smoking of counterfeit cigarettes may lead to occurrences of atrial fibrillation.

  2. Use of Ground Penetrating Radar for Locating Contraband Aboard Ocean Going Vessels: Feasibility Study

    National Research Council Canada - National Science Library

    Llopis, Jose

    2001-01-01

    Ground Penetrating Radar (GPR) surveys were conducted over various stockpiled materials at the Alabama state Docks located in Mobile, AL, to determine whether GPR is a viable method for rapidly detecting contraband materials...

  3. An enhanced functional interrogation/manipulation of intracellular signaling pathways with the peptide 'stapling' technology.

    Science.gov (United States)

    He, Y; Chen, D; Zheng, W

    2015-11-12

    Specific protein-protein interactions (PPIs) constitute a key underlying mechanism for the presence of a multitude of intracellular signaling pathways, which are essential for the survival of normal and cancer cells. Specific molecular blockers for a crucial PPI would therefore be invaluable tools for an enhanced functional interrogation of the signaling pathway harboring this particular PPI. On the other hand, if a particular PPI is essential for the survival of cancer cells but is absent in or dispensable for the survival of normal cells, its specific molecular blockers could potentially be developed into effective anticancer therapeutics. Due to the flat and extended PPI interface, it would be conceivably difficult for small molecules to achieve an effective blockade, a problem which could be potentially circumvented with peptides or proteins. However, the well-documented proteolytic instability and cellular impermeability of peptides and proteins in general would make their developing into effective intracellular PPI blockers quite a challenge. With the advent of the peptide 'stapling' technology which was demonstrated to be able to stabilize the α-helical conformation of a peptide via bridging two neighboring amino-acid side chains with a 'molecular staple', a linear parent peptide could be transformed into a stronger PPI blocker with enhanced proteolytic stability and cellular permeability. This review will furnish an account on the peptide 'stapling' technology and its exploitation in efforts to achieve an enhanced functional interrogation or manipulation of intracellular signaling pathways especially those that are cancer relevant.

  4. Detection of Special Nuclear Material in Cargo Containers Using Neutron Interrogation

    International Nuclear Information System (INIS)

    Slaughter, D.; Accatino, M.; Bernstein, A.; Candy, J.; Dougan, A.; Hall, J.; Loshak, A.; Manatt, D.; Meyer, A.; Pohl, B.; Prussin, S.; Walling, R.; Weirup, D.

    2003-01-01

    The goal of the work reported here is to develop a concept for an active neutron interrogation system that can detect small targets of SNM contraband in cargo containers, roughly 5 kg HEU or 1 kg Pu, even when well shielded by a thick cargo. It is essential that the concept be reliable and have low false-positive and false-negative error rates. It also must be rapid to avoid interruption of commerce, completing the analysis in minutes. A new radiation signature unique to SNM has been identified that utilizes high-energy (E γ = 3-7 MeV) fission product γ-ray emission. Fortunately, this high-energy γ-ray signature is robust in that it is very distinct compared to normal background radiation where there is no comparable high-energy γ-ray radiation. Equally important, it has a factor of 10 higher yield than delayed neutrons that are the basis of classical interrogation technique normally used on small unshielded specimens of SNM. And it readily penetrates two meters of low-Z and high-Z cargo at the expected density of ∼ 0.5 gm/cm 3 . Consequently, we expect that in most cases the signature flux at the container wall is at least 2-3 decades more intense than delayed neutron signals used historically and facilitates the detection of SNM even when shielded by thick cargo. Experiments have verified this signature and its predicted characteristics. However, they revealed an important interference due to the activation of 16 O by the 16 O(n,p) 16 N reaction that produces a 6 MeV γ-ray following a 7-sec β-decay of the 16 N. This interference is important when irradiating with 14 MeV neutrons but is eliminated when lower energy neutron sources are utilized since the reaction threshold for 16 O(n,p) 16 N is 10 MeV. The signature γ-ray fluxes exiting a thick cargo can be detected in large arrays of scintillation detectors to produce useful signal count rates of 2-4 x 10 4 cps. That is high enough to quickly identify SNM fission by its characteristic high energy

  5. Psychological Perspectives on Interrogation.

    Science.gov (United States)

    Vrij, Aldert; Meissner, Christian A; Fisher, Ronald P; Kassin, Saul M; Morgan, Charles A; Kleinman, Steven M

    2017-11-01

    Proponents of "enhanced interrogation techniques" in the United States have claimed that such methods are necessary for obtaining information from uncooperative terrorism subjects. In the present article, we offer an informed, academic perspective on such claims. Psychological theory and research shows that harsh interrogation methods are ineffective. First, they are likely to increase resistance by the subject rather than facilitate cooperation. Second, the threatening and adversarial nature of harsh interrogation is often inimical to the goal of facilitating the retrieval of information from memory and therefore reduces the likelihood that a subject will provide reports that are extensive, detailed, and accurate. Third, harsh interrogation methods make lie detection difficult. Analyzing speech content and eliciting verifiable details are the most reliable cues to assessing credibility; however, to elicit such cues subjects must be encouraged to provide extensive narratives, something that does not occur in harsh interrogations. Evidence is accumulating for the effectiveness of rapport-based information-gathering approaches as an alternative to harsh interrogations. Such approaches promote cooperation, enhance recall of relevant and reliable information, and facilitate assessments of credibility. Given the available evidence that torture is ineffective, why might some laypersons, policymakers, and interrogation personnel support the use of torture? We conclude our review by offering a psychological perspective on this important question.

  6. Police practices and perceptions regarding juvenile interrogation and interrogative suggestibility.

    Science.gov (United States)

    Meyer, Jessica R; Reppucci, N Dickon

    2007-01-01

    Recent media coverage has highlighted cases in which young suspects were wrongly convicted because they provided interrogation-induced false confessions. Although youth may be more highly suggestible and easily influenced by authority than adults, police are trained to use the same psychologically coercive and deceptive tactics with youth as with adults. This investigation is the first standard documentation of the reported interrogation practices of law enforcement and police beliefs about the reliability of these techniques and their knowledge of child development. Participants were 332 law enforcement officers who completed surveys about interrogation procedures and developmental issues pertaining to youth. Results indicated that, while police acknowledge some developmental differences between youth and adults, there were indications that (1) how police perceive youth in general and how they perceive and treat them in the interrogation context may be contradictory and (2) their general view is that youth can be dealt with in the same manner as adults. Copyright (c) 2007 John Wiley & Sons, Ltd.

  7. APSTNG: Neutron interrogation for detection of nuclear and CW weapons, explosives, and drugs

    International Nuclear Information System (INIS)

    Rhodes, E.; Dickerman, C.E.; De Volpi, A.; Peters, C.W.

    1992-01-01

    A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image of each identified nuclide. The APSTNG also forms the basis for a compact fast-neutron transmission imaging system that can be used along with or instead of the emission imaging system; a collimator is not required since scattered neutrons are removed by ''electronic collimation'' (detected neutrons not having the proper flight time to be uncollided are discarded). The small and relatively inexpensive APSTNG exhibits high reliability and can be quickly replaced. Proof-of-concept experiments have been performed under laboratory conditions for simulated nuclear and chemical warfare munitions and for explosives and drugs

  8. The dynamic nature of interrogation.

    Science.gov (United States)

    Kelly, Christopher E; Miller, Jeaneé C; Redlich, Allison D

    2016-06-01

    Building on a substantial body of literature examining interrogation methods employed by police investigators and their relationship to suspect behaviors, we analyzed a sample of audio and video interrogation recordings of individuals suspected of serious violent crimes. Existing survey research has focused on the tactics reportedly used, at what rate, and under what conditions; observational studies detail which methods are actually employed. With a few notable exceptions, these foundational studies were static examinations of interrogation methods that documented the absence or presence of various approaches. In the present study, we cast interrogation as a dynamic phenomenon and code the recordings in 5-min intervals to examine how interrogation methods and suspect cooperation change over time. Employing the interrogation taxonomy framework, particularly 4 discrete domains-rapport and relationship building, emotion provocation, presentation of evidence, and confrontation/competition-we found that the emphasis of the domains varied across interrogations and were significantly different when suspects confessed versus when they denied involvement. In regression models, suspect cooperation was positively influenced by the rapport and relationship building domain, though it was negatively impacted by presentation of evidence and confrontation/competition. Moreover, we found that the negative effects of confrontation/competition on suspect cooperation lasted for up to 15 min. The implications of the findings for practice and future research include the benefits of a rapport-based approach, the deleterious effects of accusatorial methods, and the importance of studying when, not just if, certain interrogation techniques are employed. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  9. Development of fiber optic sensing interrogators for launchers

    Science.gov (United States)

    Plattner, M. P.; Buck, T. C.; Eder, B.; Reutlinger, A.; McKenzie, I.

    2017-11-01

    We present our work about the development of two complementary interrogation schemes based on fiber optic sensing for the use of structural and thermal monitoring of Ariane launchers. The advantages of fiber optic sensing in particular light-weight, immunity to electromagnetic interferences and the possibility of sensor distribution along optical fibers are driving factors for utilization of this technology in space crafts [1]. The edge-filter (EF) and scanning-laser (SL) interrogators for determination of the mean wavelength of fiber Bragg grating (FBG) sensors have been implemented as two separate demonstrators. Within this paper we describe the functional principles of both interrogators. Furthermore we present test results where the developed systems have been used for readout of FBG sensors which are implemented in an Ariane structural demonstrator during thermal, thermal-vacuum and vibration tests. Functionality of both systems is demonstrated and their potential for further development towards space qualified systems is shown. Since the performance characteristics of the two systems are different from each other, they are dedicated for different sensing applications on a launcher. The EF sensor interrogator provides a sample rate of 20 kHz at a number of 4 connected sensors and supports parallel readout and aliasing free operation. Therefore it is best suited for high priority measurement. Structural monitoring which requires the acquisition of real time sensor information in order to support control of the launcher is one operation area for a future EF system. The SL interrogator provides an overall measurement rate of 1 kHz at a number of 24 connected sensors distributed on three sensor channels. It can be adapted to any sensors that have design wavelengths lying within the output spectrum of the laser diode. Furthermore the number of overall sensors to be read out with this system can be adapted easily. Thermal mapping of satellite panels is one possible

  10. Achievable Performance and Effective Interrogator Design for SAW RFID Sensor Tags

    Science.gov (United States)

    Barton Richard J.

    2012-01-01

    For many NASA missions, remote sensing is a critical application that supports activities such as environmental monitoring, planetary science, structural shape and health monitoring, non-destructive evaluation, etc. The utility of the remote sensing devices themselves is greatly increased if they are passive V that is, they do not require any on-board power supply such as batteries V and if they can be identified uniquely during the sensor interrogation process. Additional passive sensor characteristics that enable greater utilization in space applications are small size and weight, long read ranges with low interrogator power, ruggedness, and operability in extreme environments (vacuum, extreme high/low temperature, high radiation, etc.) In this paper, we consider one very promising passive sensor technology, called surface acoustic wave (SAW) radio-frequency identification (RFID), that satisfies all of these criteria. In general, RFID is a method of identifying items using radio waves to interrogate tags encoded with a unique identifier that are affixed to the items of interest. In the case of passive tags, only the interrogator, which transmits power to the tags in the form of radio-frequency electromagnetic radiation, requires access to a power supply. Passive RFID technologies are used today in many applications, including asset tracking and management, security and access control, and remote sensing. To date, most of the development and application in RFID technology has focused on either asset/inventory tracking and control or security and access control because these are the largest commercial application areas. Recently however, there has been growing interest in using passive RFID technology for remote sensing applications, and SAW devices are at the forefront of RFID sensing technology development. Although SAW RFID tags have great potential for use in numerous space-based remote sensing applications, the limited collision resolution capability of

  11. Fast neutron radiography scanner for the detection of contraband in air cargo containers

    International Nuclear Information System (INIS)

    Eberhardt, J.E.; Rainey, S.; Stevens, R.J.; Sowerby, B.D.; Tickner, J.R.

    2005-01-01

    There is a growing need to rapidly scan bulk air cargo for contraband such as illicit drugs and explosives. The Commonwealth Science and Industrial Research Organisation (CSIRO) have been working with Australian Customs Service to develop a scanner capable of directly scanning airfreight containers in 1-2 minutes without unpacking. The scanner combines fast neutron and gamma-ray radiography to provide high-resolution images that include information on material composition. A full-scale prototype scanner has been successfully tested in the laboratory and a commercial-scale scanner is due to be installed at Brisbane airport in 2005

  12. Fast neutron radiography scanner for the detection of contraband in air cargo containers

    Energy Technology Data Exchange (ETDEWEB)

    Eberhardt, J.E. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia); Rainey, S. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia); Stevens, R.J. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia); Sowerby, B.D. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia)]. E-mail: brian.sowerby@csiro.au; Tickner, J.R. [CSIRO Minerals, Private Mail Bag 5, Menai, NSW 2234 (Australia)

    2005-08-01

    There is a growing need to rapidly scan bulk air cargo for contraband such as illicit drugs and explosives. The Commonwealth Science and Industrial Research Organisation (CSIRO) have been working with Australian Customs Service to develop a scanner capable of directly scanning airfreight containers in 1-2 minutes without unpacking. The scanner combines fast neutron and gamma-ray radiography to provide high-resolution images that include information on material composition. A full-scale prototype scanner has been successfully tested in the laboratory and a commercial-scale scanner is due to be installed at Brisbane airport in 2005.

  13. 8 CFR 343b.3 - Interrogation.

    Science.gov (United States)

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Interrogation. 343b.3 Section 343b.3 Aliens... NATURALIZATION FOR RECOGNITION BY A FOREIGN STATE § 343b.3 Interrogation. When Form N-565 presents a prima facie... issuance of the certificate. Interrogation of the applicant shall be conducted before the application is...

  14. Vapor detection of trafficking of contraband money: A discussion of technical feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Dietz, R.N.

    1996-02-01

    For every two pounds of cocaine smuggled into the US, drug traffikers are being forced to clandestinely ship three pounds of money back out for subsequent laundering. Based on tracer technology developed for validation of long-range atmospheric transport models and other commercial applications, it is shown that US currency can be tagged with a minute amount (about 1 ppm by weight of a bill) of perfluorocharbon tracer (PFT) material that is sufficient to last for about 30 years and yet provide a vapor emission rate suitable for detectability of modest caches of contraband money in vehicles at border crossings, on aircraft at international terminals, and in buildings. The cost of tagging is less than $5 per million bills; the taggant quantity should have no impact on the feel of a bill. The low emission rate would not allow detectability of usual amounts of money in typical scenarios, providing an essential degree of privacy, but extraordinary amounts would be detectable using specialized instrumentation and know-how not easily attainable but commercially in production; an example of sub-part-per-quadrillion detection of a proposed PFT taggant is demonstrated using a prototype commercial unit. An outline of a research and demonstration program to achieve this capability and details of the proposed tagging and detection procedures already indicate that the concept is technically feasible.

  15. Trace Contraband Detection Field-Test by the South Texas Specialized Crimes and Narcotics Task Force

    Energy Technology Data Exchange (ETDEWEB)

    Hannum, David W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Contraband Detection Dept.; Shannon, Gary W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Contraband Detection Dept.

    2006-04-01

    This report describes the collaboration between the South Texas Specialized Crimes and Narcotics Task Force (STSCNTF) and Sandia National Laboratories (SNL) in a field test that provided prototype hand-held trace detection technology for use in counter-drug operations. The National Institute of Justice (NIJ)/National Law Enforcement and Corrections Technology Center (NLECTC)/Border Research and Technology Center (BRTC) was contacted by STSCNTF for assistance in obtaining cutting-edge technology. The BRTC created a pilot project for Sandia National Laboratories (SNL) and the STSCNTF for the use of SNL’s Hound, a hand-held sample collection and preconcentration system that, when combined with a commercial chemical detector, can be used for the trace detection of illicit drugs and explosives. The STSCNTF operates in an area of high narcotics trafficking where methods of concealment make the detection of narcotics challenging. Sandia National Laboratories’ (SNL) Contraband Detection Department personnel provided the Hound system hardware and operational training. The Hound system combines the GE VaporTracer2, a hand-held commercial chemical detector, with an SNL-developed sample collection and preconcentration system. The South Texas Task force reported a variety of successes, including identification of a major shipment of methamphetamines, the discovery of hidden compartments in vehicles that contained illegal drugs and currency used in drug deals, and the identification of a suspect in a nightclub shooting. The main advantage of the hand-held trace detection unit is its ability to quickly identify the type of chemical (drugs or explosives) without a long lag time for laboratory analysis, which is the most common analysis method for current law enforcement procedures.

  16. Language style matching and police interrogation outcomes

    NARCIS (Netherlands)

    Richardson, Beth H.; Taylor, Paul J; Snook, Brent; Conchie, Stacey M.; Bennell, Craig

    2014-01-01

    This research examined the coordination of interrogator and suspects’ verbal behavior in interrogations. Sixty-four police interrogations were examined at the aggregate and utterance level using a measure of verbal mimicry known as Language Style Matching. Analyses revealed an interaction between

  17. Wireless interrogation of passive antenna sensors

    International Nuclear Information System (INIS)

    Deshmukh, S; Huang, H

    2010-01-01

    Recently, we discovered that the resonant frequency of a microstrip patch antenna is sensitive to mechanical strains or crack presence in the ground plane. Based on this principle, antenna sensors have been demonstrated to measure strain and detect crack in metallic structures. This paper presents a wireless method to remotely interrogate a dual-frequency antenna sensor. An interrogation horn antenna was used to irradiate the antenna sensor with a linear chirp microwave signal. By implementing a light-activated switch at the sensor node and performing signal processing of the backscattered signals, the resonant frequencies of the antenna sensor along both polarizations can be measured remotely. Since the antenna sensor does not need a local power source and can be interrogated wirelessly, electric wiring can be eliminated. The sensor implementation, the signal processing and the experimental setup that validate the remote interrogation of the antenna sensor are presented. A power budget model has also been established to estimate the maximum interrogation range

  18. Far-infrared contraband-detection-system development for personnel-search applications

    International Nuclear Information System (INIS)

    Schellenbaum, R.L.

    1982-09-01

    Experiments have been conducted toward the development of an active near-millimeter-wave, far infrared, personnel search system for the detection of contraband. These experiments employed a microwave hybrid tee interferometer/radiometer scanning system and quasi-optical techniques at 3.3-mm wavelength to illuminate and detect the reflection from target objects against a human body background. Clothing and other common concealing materials are transport at this wavelength. Retroreflector arrays, in conjunction with a Gunn diode radiation source, were investigated to provide all-angle illumination and detection of specular reflections from unaligned and irregular-shaped objects. Results indicate that, under highly controlled search conditions, metal objects greater than or equal to 25 cm 2 can be detected in an enclosure lined with retroreflectors. Further development is required to produce a practical personnel search system. The investigation and feasibility of alternate far infrared search techniques are presented. 23 figures, 2 tables

  19. Determination of contraband using fast neutron resonance technique

    Energy Technology Data Exchange (ETDEWEB)

    Bae, J.; Whang, J. [Kyunghee Univ., Dept. of Nuclear Engineering, Yongin-shi, Kyongki-do (Korea, Republic of)

    2004-07-01

    'Full-text:' Resonance technique with monoenergetic fast neutron beam is able to map features in bulk samples in a way that is sensitive to their elemental composition. It has a number of potential applications, for example, in mining and in the detection of contraband materials such as illicit drugs and explosives. By moving around the neutron detector experiences neutrons in the form of narrow line beam with different energies as the angle to the neutron source changes. Projection data was obtained using the Monte Carlo code MCNP4C. Therefore the fast neutrons scattered from an unknown object are used to determine the elemental content of the object and hence lead to its identification. Scattered features simulated for various test materials are analyzed using the HEPRO program system (PTB, Braunschweig) to determine the atom weight fractions for H. C. N, O and other elements in the materials. Atom weight fractions determined from scattering features are insensitive to neutron interactions in interfering materials surrounding the object. The simulations demonstrate that the fast neutron resonance technique (FNRT) provides reliable elemental characterization of bulk materials and has the necessary sensitivity to distinguish between drugs, explosives and other materials. (author)

  20. Determination of contraband using fast neutron resonance technique

    International Nuclear Information System (INIS)

    Bae, J.; Whang, J.

    2004-01-01

    'Full-text:' Resonance technique with monoenergetic fast neutron beam is able to map features in bulk samples in a way that is sensitive to their elemental composition. It has a number of potential applications, for example, in mining and in the detection of contraband materials such as illicit drugs and explosives. By moving around the neutron detector experiences neutrons in the form of narrow line beam with different energies as the angle to the neutron source changes. Projection data was obtained using the Monte Carlo code MCNP4C. Therefore the fast neutrons scattered from an unknown object are used to determine the elemental content of the object and hence lead to its identification. Scattered features simulated for various test materials are analyzed using the HEPRO program system (PTB, Braunschweig) to determine the atom weight fractions for H. C. N, O and other elements in the materials. Atom weight fractions determined from scattering features are insensitive to neutron interactions in interfering materials surrounding the object. The simulations demonstrate that the fast neutron resonance technique (FNRT) provides reliable elemental characterization of bulk materials and has the necessary sensitivity to distinguish between drugs, explosives and other materials. (author)

  1. Police interrogations through the prism of science

    Directory of Open Access Journals (Sweden)

    Igor Areh

    2016-03-01

    Full Text Available Several approaches can be employed for information gathering from human sources, differing in their theoretical basis, goals, realisation, and ethical acceptability. The paper critically presents and compares two prevalent approaches to suspect interrogation used by the police. The older, prevalent interrogation approach focuses on obtaining suspects’ incriminating statements and admissions, which severely elevates the risk of false confessions. Consequently, this interrogation approach is termed accusatorial or coercive since suspects are forced to admit to a crime. The newer interrogation approach is the information-gathering approach, also known as the investigative interview. It focuses on gathering accurate information in order to exclude or accuse a suspect in a criminal investigation. In comparison with coercive interrogation models, the information-gathering approach has a lower probability of false confessions since suspects are exposed to significantly lower levels of psychological pressure. Moreover, it is ethically more acceptable, has scientific grounds, enables the gathering of more accurate information, and has been found to be at least as effective as the coercive approach in criminal investigations. The investigative interview relies mainly on findings from social psychology. An analysis of coercive interrogation models reveals that they have no scientific basis and as such rely mainly on uncorroborated common-sense assumptions from authorities. In developed countries, coercive interrogation models are increasingly being replaced by the information-gathering approach, a trend connected with the enforcement of high human rights standards and a higher awareness of risks associated with coercive interrogation methods by the general public, academia, and professionals alike.

  2. Interrogative suggestibility in opiate users.

    Science.gov (United States)

    Murakami, A; Edelmann, R J; Davis, P E

    1996-09-01

    The present study investigated interrogative suggestibility in opiate users. A group of patients undergoing a methadone detoxification programme in an in-patient drug treatment unit (Detox group, n = 21), and a group of residents who had come off drugs and were no longer suffering from withdrawal syndrome (Rehab group, n = 19) were compared on interrogative suggestibility and various other psychological factors. Significant differences were found between the two groups, with the Detox group having more physical and psychological problems, and a higher total suggestibility score in comparison with the Rehab group. These findings are discussed in relation to the context of police interrogations and the reliability of confessions made by suspects and witnesses dependent on opiates.

  3. Photon interrogation for bulk measurement of transuranic materials

    International Nuclear Information System (INIS)

    Nieschmidt, E.B.

    1981-01-01

    Investigation and assay of high atomic number materials may be accomplished in near real-time through use of photon interrogation. Photon interrogation, as used here, involves the use of high-energy photons to induce fission and then detect neutrons associated with the fission. This technique has the advantage that the interrogating particle and the detected particle are different. The discussion here will include: (1) neutron production; (2) photon production; (3) neutron counting; (4) sensitivity; and (5) problems associated with large containers. In summary, the attributes and limitations of photon interrogation can be stated as: near real-time accountability; interrogating particle different than detected particle; ability to count prompt or delayed neutrons depending on matrix; radiography or therapy accelerators available; cannot distinguish between fission and fertile material; and interrogated material must be well characterized to obtain safeguards quality results

  4. Directed Neutron Beams From Inverse Kinematic Reactions

    Science.gov (United States)

    Vanhoy, J. R.; Guardala, N. A.; Glass, G. A.

    2011-06-01

    Kinematic focusing of an emitted fairly mono-energetic neutron beam by the use of inverse-kinematic reactions, i.e. where the projectile mass is greater than the target atom's mass, can provide for the utilization of a significant fraction of the fast neutron yield and also provide for a safer radiation environment. We examine the merit of various neutron production reactions and consider the practicalities of producing the primary beam using the suitable accelerator technologies. Preliminary progress at the NSWC-Carderock Positive Ion Accelerator Facility is described. Possible important applications for this type of neutron-based system can be both advanced medical imaging techniques and active "stand-off" interrogation of contraband items.

  5. Fiber Bragg grating sensor interrogators on chip: challenges and opportunities

    Science.gov (United States)

    Marin, Yisbel; Nannipieri, Tiziano; Oton, Claudio J.; Di Pasquale, Fabrizio

    2017-04-01

    In this paper we present an overview of the current efforts towards integration of Fiber Bragg Grating (FBG) sensor interrogators. Different photonic integration platforms will be discussed, including monolithic planar lightwave circuit technology, silicon on insulator (SOI), indium phosphide (InP) and gallium arsenide (GaAs) material platforms. Also various possible techniques for wavelength metering and methods for FBG multiplexing will be discussed and compared in terms of resolution, dynamic performance, multiplexing capabilities and reliability. The use of linear filters, array waveguide gratings (AWG) as multiple linear filters and AWG based centroid signal processing techniques will be addressed as well as interrogation techniques based on tunable micro-ring resonators and Mach-Zehnder interferometers (MZI) for phase sensitive detection. The paper will also discuss the challenges and perspectives of photonic integration to address the increasing requirements of several industrial applications.

  6. Epithermal interrogation of fissile waste

    International Nuclear Information System (INIS)

    Coop, K.L.; Hollas, C.L.

    1996-01-01

    Self-shielding of interrogating thermal neutrons in lumps of fissile material can be a major source of error in transuranic waste assay using the widely employed differential dieaway technique. We are developing a new instrument, the combined thermal/epithermal neutron (CTEN) interrogation instrument to detect the occurrence of self- shielding and mitigate its effects. Neutrons are moderated in the graphite walls of the CTEN instrument to provide an interrogating flux of epithermal and thermal neutrons. The induced prompt fission neutrons are detected in proportional counters. We report the results of measurements made with the CTEN instrument, using minimal and highly self-shielding plutonium and uranium sources in 55 gallon drums containing a variety of mock waste matrices. Fissile isotopes and waste forms for which the method is most applicable, and limitations associated with the hydrogen content of the waste package/matrix are described

  7. Interrogative suggestibility in patients with conversion disorders.

    Science.gov (United States)

    Foong, J; Lucas, P A; Ron, M A

    1997-09-01

    We tested the hypothesis that increased interrogative suggestibility may contribute to the shaping and maintaining of conversions symptoms. Interrogative suggestibility was measured in 12 patients with conversion disorder and 10 control patients with confirmed neurological disease matched for age, premorbid intelligence, and as closely as possible in terms of their neurological symptoms to the patients with conversion disorder. Our observations do not support the contention that individual differences in interrogative suggestibility are of importance in the etiology of conversion disorders.

  8. Physics-based, Bayesian sequential detection method and system for radioactive contraband

    Science.gov (United States)

    Candy, James V; Axelrod, Michael C; Breitfeller, Eric F; Chambers, David H; Guidry, Brian L; Manatt, Douglas R; Meyer, Alan W; Sale, Kenneth E

    2014-03-18

    A distributed sequential method and system for detecting and identifying radioactive contraband from highly uncertain (noisy) low-count, radionuclide measurements, i.e. an event mode sequence (EMS), using a statistical approach based on Bayesian inference and physics-model-based signal processing based on the representation of a radionuclide as a monoenergetic decomposition of monoenergetic sources. For a given photon event of the EMS, the appropriate monoenergy processing channel is determined using a confidence interval condition-based discriminator for the energy amplitude and interarrival time and parameter estimates are used to update a measured probability density function estimate for a target radionuclide. A sequential likelihood ratio test is then used to determine one of two threshold conditions signifying that the EMS is either identified as the target radionuclide or not, and if not, then repeating the process for the next sequential photon event of the EMS until one of the two threshold conditions is satisfied.

  9. Miniature and low cost fiber Bragg grating interrogator for structural monitoring in nano-satellites

    Science.gov (United States)

    Toet, P. M.; Hagen, R. A. J.; Hakkesteegt, H. C.; Lugtenburg, J.; Maniscalco, M. P.

    2017-11-01

    In this paper we present a newly developed Fiber Optic measurement system, consisting of Fiber Bragg Grating (FBG) sensors and an FBG interrogator. The development of the measuring system is part of the PiezoElectric Assisted Smart Satellite Structure (PEASSS) project, which was initiated at the beginning of 2013 and is financed by the Seventh Framework Program (FP7) of the European Commission. Within the PEASSS project, a Nano-Satellite is being designed and manufactured to be equipped with new technology that will help keep Europe on the cutting edge of space research, potentially reducing the cost and development time for more accurate future sensor platforms including synthetic aperture optics, moving target detection and identification, and compact radars. After on ground testing the satellite is planned to be launched at the end of 2015. Within the satellite, different technologies will be demonstrated on orbit to show their capabilities for different in-space applications. For our application the FBG interrogator monitors the structural and thermal behaviour of a so called "smart panel". These panels will enable fine angle control and thermal and vibration compensation in order to improve all types of future Earth observations, such as environmental and planetary mapping, border and regional imaging. The Fiber Optic (FO) system in PEASSS includes four FBG strain sensors and two FBG temperature sensors. The 3 channel interrogator has to have a small footprint (110x50x40mm), is low cost, low in mass and has a low power consumption. In order to meet all these requirements, an interrogator has been designed based on a tunable Vertical-Cavity Surface-Emitting Laser (VCSEL) enabling a wavelength sweep of around 7 nm. To guarantee the absolute and relative performance, two reference methods are included internally in the interrogator. First, stabilized reference FBG sensors are used to obtain absolute wavelength calibrations. This method is used for the temperature

  10. Micro elements for interrogating magnetoelastic sensors

    KAUST Repository

    Liang, Cai

    2011-11-01

    This paper reports a new approach for interrogating a magnetoelastic sensor\\'s resonant frequency. Previously, the frequency of a magnetoelastic sensor was measured by using a large-scale solenoid coil of at least some millimeters both in diameter and length. Planar structures of straight-line and rectangular spiral coil are designed, fabricated and tested to interrogate the resonant frequency of a magnetoelastic sensor. A sensor of 4 mm length is measured to have a resonant frequency of 551 kHz in air. The ability to interrogate a magnetoelastic sensor with such microscale elements is a step towards the miniaturization of a magnetoelastic sensor system and integration of such a system in a microfluidics device. © 2011 IEEE.

  11. Technologies for detection of nuclear materials

    International Nuclear Information System (INIS)

    DeVolpi, A.

    1996-01-01

    Detection of smuggled nuclear materials at transit points requires monitoring unknown samples in large closed packages. This review contends that high-confidence nuclear-material detection requires induced fission as the primary mechanism, with passive radiation screening in a complementary role. With the right equipment, even small quantities of nuclear materials are detectable with a high probability at transit points. The equipment could also be linked synergistically with detectors of other contrabond. For screening postal mail and packages, passive monitors are probably more cost-effective. When a suspicious item is detected, a single active probe could then be used. Until active systems become mass produced, this two-stage screening/interrogation role for active/passive equipment is more economic for cargo at border crossings. For widespread monitoring of nuclear smuggling, it will probably be necessary to develop a system for simultaneously detecting most categories of contraband, including explosives and illicit drugs. With control of nuclear materials at known storage sites being the first line of defense, detection capabilities at international borders could establish a viable second line of defense against smuggling

  12. Design of a fiber-optic interrogator module for telecommunication satellites

    Science.gov (United States)

    Putzer, Philipp; Koch, Alexander W.; Plattner, Markus; Hurni, Andreas; Manhart, Markus

    2017-11-01

    In this paper we present the results of the radiation tests performed on the optical components of the fiber-optic interrogator module as a part of the Hybrid Sensor Bus (HSB) system. The HSB-system is developed in the frame of an ESAARTES program and will be verified as flight demonstrator onboard the German Heinrich Hertz satellite in 2016. The HSB system is based on a modular concept which includes sensor interrogation modules based on I2C electrical and fiber Bragg grating (FBG) fiber-optical sensor elements. Onboard fiber-optic sensing allows the implementation of novel control and monitoring methods. For read-out of multiple FBG sensors, a design based on a tunable laser diode as well as a design based on a spectrometer is considered. The expected and tested total ionizing dose (TID) applicable to the HSB system is in the range between 100 krad and 300 krad inside the satellite in the geostationary orbit over a life time of 15 years. We present radiation test results carried out on critical optical components to be used in the fiber-optic interrogation module. These components are a modulated grating Y-branch (MGY) tunable laser diode acting as light source for the tuning laser approach, the line detector of a spectrometer, photodetectors and the FBG sensors acting as sensor elements. A detailed literature inquiry of radiation effects on optical fibers and FBG sensors, is also included in the paper. The fiber-optic interrogator module implemented in the HSB system is based on the most suitable technology, which sustains the harsh environment in the geostationary orbit.

  13. 32 CFR 637.21 - Recording interviews and interrogations.

    Science.gov (United States)

    2010-07-01

    ... ENFORCEMENT AND CRIMINAL INVESTIGATIONS MILITARY POLICE INVESTIGATION Investigations § 637.21 Recording interviews and interrogations. The recording of interviews and interrogations by military police personnel is...

  14. An adaptive sampling and windowing interrogation method in PIV

    Science.gov (United States)

    Theunissen, R.; Scarano, F.; Riethmuller, M. L.

    2007-01-01

    This study proposes a cross-correlation based PIV image interrogation algorithm that adapts the number of interrogation windows and their size to the image properties and to the flow conditions. The proposed methodology releases the constraint of uniform sampling rate (Cartesian mesh) and spatial resolution (uniform window size) commonly adopted in PIV interrogation. Especially in non-optimal experimental conditions where the flow seeding is inhomogeneous, this leads either to loss of robustness (too few particles per window) or measurement precision (too large or coarsely spaced interrogation windows). Two criteria are investigated, namely adaptation to the local signal content in the image and adaptation to local flow conditions. The implementation of the adaptive criteria within a recursive interrogation method is described. The location and size of the interrogation windows are locally adapted to the image signal (i.e., seeding density). Also the local window spacing (commonly set by the overlap factor) is put in relation with the spatial variation of the velocity field. The viability of the method is illustrated over two experimental cases where the limitation of a uniform interrogation approach appears clearly: a shock-wave-boundary layer interaction and an aircraft vortex wake. The examples show that the spatial sampling rate can be adapted to the actual flow features and that the interrogation window size can be arranged so as to follow the spatial distribution of seeding particle images and flow velocity fluctuations. In comparison with the uniform interrogation technique, the spatial resolution is locally enhanced while in poorly seeded regions the level of robustness of the analysis (signal-to-noise ratio) is kept almost constant.

  15. Maritime security report. April 1997 [Maritime smuggling of drugs and contraband goods through Haiti adversely impacting legitimate commerce and development; Partnering : a key to growing challenges confronting maritime security

    Science.gov (United States)

    1997-04-01

    Haiti is a significant transshipment conduit for South American cocaine destined for the United States. This smuggling is facilitated by Haitis system of seaports which remain largely unmonitored. Smuggling and trafficking contraband merchandise aver...

  16. Interrogative constructions in Danish Sign Language (DSL)

    DEFF Research Database (Denmark)

    Hansen, Julie

    This study investigates the primary types of interrogative constructions: Polar and content questions. The aim is to identify how and in which types of interrogative constructions the non-manual patterns described by Engberg-Pedersen (1993, 1998)are used. Furthermore, the aim is to identify...

  17. Miniature fiber Bragg grating sensor interrogator (FBG-Transceiver) system

    Science.gov (United States)

    Mendoza, Edgar A.; Kempen, Cornelia; Lopatin, Craig

    2007-04-01

    This paper describes recent progress conducted towards the development of a miniature fiber Bragg grating sensor interrogator (FBG-Transceiver TM) system based on multi-channel integrated optic sensor (InOSense TM) microchip technology. The hybrid InOSense TM microchip technology enables the integration of all of the functionalities, both passive and active, of conventional bench top FBG sensor interrogator systems, packaged in a miniaturized, low power operation, 2-cm x 5-cm package suitable for the long-term structural health monitoring in applications where size, weight, and power are critical for operation. The FBG-Transceiver system uses active optoelectronic components monolithically integrated to the InOSense TM microchip, a microprocessor controlled signal processing electronics board capable of processing the FBG sensors signals related to stress-strain and temperature as well as vibration and acoustics. The FBG-Transceiver TM system represents a new, reliable, highly robust technology that can be used to accurately monitor the status of an array of distributed fiber optic Bragg grating sensors installed in critical infrastructures. Its miniature package, low power operation, and state-of-the-art data communications architecture, all at a very affordable price makes it a very attractive solution for a large number of SHM/NDI applications in aerospace, naval and maritime industry, civil structures like bridges, buildings and dams, the oil and chemical industry, and for homeland security applications. The miniature, cost-efficient FBG-Transceiver TM system is poised to revolutionize the field of structural health monitoring and nondestructive inspection market. The sponsor of this program is NAVAIR under a DOD SBIR contract.

  18. Adaptive interrogation for 3D-PIV

    International Nuclear Information System (INIS)

    Novara, Matteo; Scarano, Fulvio; Ianiro, Andrea

    2013-01-01

    A method to adapt the shape and orientation of interrogation volumes for 3D-PIV motion analysis is introduced, aimed to increase the local spatial resolution. The main application of this approach is the detailed analysis of complex 3D and vortex-dominated flows that exhibit high vorticity in confined regions like shear layers and vortex filaments. The adaptive criterion is based on the analysis of the components of the local velocity gradient tensor, which returns the level of anisotropy of velocity spatial fluctuations. The principle to increase the local spatial resolution is based on the deformation of spherical isotropic interrogation regions, obtained by means of Gaussian weighting, into ellipsoids, with free choice of the principal axes and their directions. The interrogation region is contracted in the direction of the maximum velocity variation and elongated in the minimum one in order to maintain a constant interrogation volume. The adaptivity technique for three-dimensional PIV data takes advantage of the 3D topology of the flow, allowing increasing the spatial resolution not only in the case of shear layers, but also for vortex filaments, which is not possible for two-dimensional measurement in the plane normal to the vortex axis. The definition of the ellipsoidal interrogation region semi-axes is based on the singular values and singular directions of the local velocity gradient tensor as obtained by the singular values decomposition technique (SVD). The working principle is verified making use of numerical simulations of a shear layer and of a vortex filament. The application of the technique to data from a Tomo-PIV experiment conducted on a round jet, shows that the resolution of the shear layer at the jet exit can be considerably improved and an increase of about 25% in the vorticity peak is attained when the adaptive approach is applied. On the other hand, the peak vorticity description in the core of vortex rings is only slightly improved with

  19. Design challenges of a tunable laser interrogator for geo-stationary communication satellites

    Science.gov (United States)

    Ibrahim, Selwan K.; Honniball, Arthur; McCue, Raymond; Todd, Michael; O'Dowd, John A.; Sheils, David; Voudouris, Liberis; Farnan, Martin; Hurni, Andreas; Putzer, Philipp; Lemke, Norbert; Roner, Markus

    2017-09-01

    Recently optical sensing solutions based on fiber Bragg grating (FBG) technology have been proposed for temperature monitoring in telecommunication satellite platforms with an operational life time beyond 15 years in geo-stationary orbit. Developing radiation hardened optical interrogators designed to be used with FBG sensors inscribed in radiation tolerant fibers offer the capabilities of multiplexing multiple sensors on the same fiber and reducing the overall weight by removing the copper wiring harnesses associated with electrical sensors. Here we propose the use of a tunable laser based optical interrogator that uses a semiconductor MG-Y type laser that has no moving parts and sweeps across the C-band wavelength range providing optical power to FBG sensors and optical wavelength references such as athermal Etalons and Gas Cells to guarantee stable operation of the interrogator over its targeted life time in radiation exposed environments. The MG-Y laser was calibrated so it remains in a stable operation mode which ensures that no mode hops occur due to aging of the laser, and/or thermal or radiation effects. The key optical components including tunable laser, references and FBGs were tested for radiation tolerances by emulating the conditions on a geo-stationary satellite including a Total Ionizing Dose (TID) radiation level of up to 100 krad for interrogator components and 25 Mrad for FBGs. Different tunable laser control, and signal processing algorithms have been designed and developed to fit within specific available radiation hardened FPGAs to guarantee operation of a single interrogator module providing at least 1 sample per second measurement capability across engineering model system developed in the frame of an ESA-ARTES program and is planned to be deployed as a flight demonstrator on-board the German Heinrich Hertz geo-stationary satellite.

  20. Interrogating Planar Cyclooctatetraenes

    DEFF Research Database (Denmark)

    Hensel, Thomas

    ]circulenes were established. The antiaromaticity of the formal COT core of the hetero[8]circulenes was interrogated by comparison of the respective 13C-NMR carbon shifts with those of 3,6-dimethoxycarbazole (the starting material), tetrahydroxy intermediate and literature values. No uniform paratropic...

  1. 29 CFR 18.614 - Calling and interrogation of witnesses by judge.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Calling and interrogation of witnesses by judge. 18.614... interrogation of witnesses by judge. (a) Calling by the judge. The judge may, on the judge's own motion or at... thus called. (b) Interrogation by the judge. The judge may interrogate witnesses, whether called by the...

  2. Bright Lights and Questions: Using Mutual Interrogation

    Science.gov (United States)

    Adam, Aishikin; Alangui, Willy; Barton, Bill

    2010-01-01

    Mutual Interrogation is a research methodology for ethnomathematics proposed by Alangui in 2006 in an attempt to avoid the potential inequality set up when a restricted cultural practice is viewed through the lens of the near-universal and highly developed research domain of mathematics. Using three significant examples of mutual interrogation in…

  3. Safety and efficiency of emergency department interrogation of cardiac devices.

    Science.gov (United States)

    Neuenschwander, James F; Peacock, W Frank; Migeed, Madgy; Hunter, Sara A; Daughtery, John C; McCleese, Ian C; Hiestand, Brian C

    2016-12-01

    Patients with implanted cardiac devices may wait extended periods for interrogation in emergency departments (EDs). Our purpose was to determine if device interrogation could be done safely and faster by ED staff. Prospective randomized, standard therapy controlled, trial of ED staff device interrogation vs. standard process (SP), with 30-day follow-up. Eligibility criteria: ED presentation with a self-report of a potential device related complaint, with signed informed consent. SP interrogation was by company representative or hospital employee. Of 60 patients, 42 (70%) were male, all were white, with a median (interquartile range) age of 71 (64 to 82) years. No patient was lost to follow up. Of all patients, 32 (53%) were enrolled during business hours. The overall median (interquartile range) ED vs. SP time to interrogation was 98.5 (40 to 260) vs. 166.5 (64 to 412) minutes (P=0.013). While ED and SP interrogation times were similar during business hours, 102 (59 to 138) vs. 105 (64 to 172) minutes (P=0.62), ED interrogation times were shorter vs. SP during non-business hours; 97 (60 to 126) vs. 225 (144 to 412) minutes, P=0.002, respectively. There was no difference in ED length of stay between the ED and SP interrogation, 249 (153 to 390) vs. 246 (143 to 333) minutes (P=0.71), regardless of time of presentation. No patient in any cohort suffered an unplanned medical contact or post-discharge adverse device related event. ED staff cardiac device interrogations are faster, and with similar 30-day outcomes, as compared to SP.

  4. "Enhanced" interrogation of detainees: do psychologists and psychiatrists participate?

    OpenAIRE

    Halpern, Abraham L; Halpern, John H; Doherty, Sean B

    2008-01-01

    Abstract After revelations of participation by psychiatrists and psychologists in interrogation of prisoners at Guantánamo Bay and Central Intelligence Agency secret detention centers, the American Psychiatric Association and the American Psychological Association adopted Position Statements absolutely prohibiting their members from participating in torture under any and all circumstances, and, to a limited degree, forbidding involvement in interrogations. Some interrogations utilize very agg...

  5. Opium: The Evolution of Policies, the Tolerance of the Vice, and the Proliferation of Contraband Trade in the Philippines, 1843-1908

    OpenAIRE

    Alma N. Bamero

    2006-01-01

    This research entitled “Opium: The Evolution of Policies, the Tolerance of the Vice, and the Proliferation of Contraband Trade in the Philippines, 1843-1908” presents a discussion of the opium trade in Asia, the commercial networks it created, the political ties it strengthened, and the social relations itfostered. It also aims to reconstruct an aspect of Philippine social history in the nineteenth century through the use of archival materials that bear witness to the distribution and exploit...

  6. Quantum prisoners' dilemma under enhanced interrogation

    Science.gov (United States)

    Siopsis, George; Balu, Radhakrishnan; Solmeyer, Neal

    2018-06-01

    In the quantum version of prisoners' dilemma, each prisoner is equipped with a single qubit that the interrogator can entangle. We enlarge the available Hilbert space by introducing a third qubit that the interrogator can entangle with the other two. We discuss an enhanced interrogation technique based on tripartite entanglement and analyze Nash equilibria. We show that for tripartite entanglement approaching a W-state, we calculate the Nash equilibria numerically and show that they coincide with the Pareto-optimal choice where both prisoners cooperate. Upon continuous variation between a W-state and a pure bipartite entangled state, the game is shown to have a surprisingly rich structure. The role of bipartite and tripartite entanglement is explored to explain that structure. As an application, we consider an evolutionary game based on our quantum game with a network of agents on a square lattice with periodic boundary conditions and show that the strategy corresponding to Nash equilibrium completely dominates without placing any restrictions on the initial set of strategies.

  7. The role of abusive states of being in interrogation.

    Science.gov (United States)

    Putnam, Frank W

    2013-01-01

    Interrogation, the questioning of persons detained by police, military, or intelligence organizations, is designed to extract information that a subject may resist disclosing. Interrogation techniques are frequently predicated on inducing mental states of despair, dread, dependency, and debility that weaken an individual's resistance. Descriptions of techniques from 2 Central Intelligence Agency training manuals are illustrated by examples from interviews of and writings by Murat Kurnaz, who was held at Guantánamo Bay Detention Camp for 5 years. Interrogation techniques are designed to create a destabilizing sense of shock; undermine an individual's grasp on reality; and provoke internal psychological division, self-conflict, and confusion. The long-term effects of interrogation often include posttraumatic stress disorder as well as states of anxiety, depression, and depersonalization.

  8. Advanced FBG sensing through rapid spectral interrogation

    Science.gov (United States)

    Kunzler, Wesley; Newman, Jason; Wilding, Daniel; Zhu, Zixu; Lowder, Tyson; Selfridge, Richard; Schultz, Stephen; Wirthlin, Michael

    2008-03-01

    A fiber Brag grating sensor interrogator has been developed which is capable of gathering vectors of information from individual fiber Bragg gratings by capturing the full optical spectrum 3 kHz. Using a field programmable gate array with high speed digital-to-analog converters and analog-to-digital components, plus a kilohertz rate MEMS optical filter, the optical spectrum can be scanned at rates in excess of 10 million nanometers per second, allowing sensor sampling rates of many kilohertz while maintaining the necessary resolution to understand sensor changes. The autonomous system design performs all necessary detection and processing of multiple sensors and allows spectral measurements to be exported as fast as Ethernet, USB, or RS232 devices can receive it through a memory mapped interface. The high speed - full spectrum - fiber Bragg grating sensor interrogator enables advanced interrogation of dynamic strain and temperature gradients along the length of a sensor, as well as the use of each sensor for multiple stimuli, such as in temperature compensation. Two examples are described, showing interrogation of rapid laser heating in an optical fiber, as well as complex strain effects in a beam that had an engineered defect.

  9. Associated-particle sealed-tube neutron probe: Detection of explosives, contraband, and nuclear materials

    International Nuclear Information System (INIS)

    Rhodes, E.; Dickerman, C.E.

    1996-01-01

    Continued research and development of the APSTNG shows the potential for practical field use of this technology for detection of explosives, contraband, and nuclear materials. The APSTNG (associated-particle sealed-tube generator) inspects the item to be examined using penetrating 14-MeV neutrons generated by the deuterium-tritium reaction inside a compact accelerator tube. An alpha detector built into the sealed tube detects the alpha-particle associated with each neutron emitted in a cone encompassing the volume to be inspected. Penetrating high-energy gamma-rays from the resulting neutron reactions identify specific nuclides inside the volume. Flight-times determined from the detection times of gamma-rays and alpha-particles separate the prompt and delayed gamma-ray spectra and allow a coarse 3-D image to be obtained of nuclides identified in the prompt spectrum. The generator and detectors can be on the same side of the inspected object, on opposite sides, or with intermediate orientations. Thus, spaces behind walls and other confined regions can be inspected. Signals from container walls can be discriminated against using the flight-time technique. No collimators or shielding are required, the neutron generator is relatively small, and commercial-grade electronics are employed. The use of 14-MeV neutrons yields a much higher cross-section for detecting nitrogen than that for systems based on thermal-neutron reactions alone, and the broad range of elements with significant 14-MeV neutron cross-sections extends explosives detection to other elements including low-nitrogen compounds, and allows detection of many other substances. Proof-of-concept experiments have been successfully performed for conventional explosives, chemical warfare agents, cocaine, and fissionable materials

  10. SIMULATION OF CARGO CONTAINER INTERROGATION BY D-D NEUTRONS

    International Nuclear Information System (INIS)

    Lou, Tak Pui; Antolak, Arlyn

    2007-01-01

    High fidelity, three-dimensional computer models based on a CAD drawing of an intermodal cargo container, representative payload objects, and detector array panels were developed to simulate the underlying physical events taking place during active interrogation. These computer models are used to assess the performance of interrogation systems with different sources and detection schemes. In this presentation, we will show that the use oversimplified models, such as analyzing homogenized payloads only, can lead to errors in determining viable approaches for interrogation

  11. Notes on SAW Tag Interrogation Techniques

    Science.gov (United States)

    Barton, Richard J.

    2010-01-01

    We consider the problem of interrogating a single SAW RFID tag with a known ID and known range in the presence of multiple interfering tags under the following assumptions: (1) The RF propagation environment is well approximated as a simple delay channel with geometric power-decay constant alpha >/= 2. (2) The interfering tag IDs are unknown but well approximated as independent, identically distributed random samples from a probability distribution of tag ID waveforms with known second-order properties, and the tag of interest is drawn independently from the same distribution. (3) The ranges of the interfering tags are unknown but well approximated as independent, identically distributed realizations of a random variable rho with a known probability distribution f(sub rho) , and the tag ranges are independent of the tag ID waveforms. In particular, we model the tag waveforms as random impulse responses from a wide-sense-stationary, uncorrelated-scattering (WSSUS) fading channel with known bandwidth and scattering function. A brief discussion of the properties of such channels and the notation used to describe them in this document is given in the Appendix. Under these assumptions, we derive the expression for the output signal-to-noise ratio (SNR) for an arbitrary combination of transmitted interrogation signal and linear receiver filter. Based on this expression, we derive the optimal interrogator configuration (i.e., transmitted signal/receiver filter combination) in the two extreme noise/interference regimes, i.e., noise-limited and interference-limited, under the additional assumption that the coherence bandwidth of the tags is much smaller than the total tag bandwidth. Finally, we evaluate the performance of both optimal interrogators over a broad range of operating scenarios using both numerical simulation based on the assumed model and Monte Carlo simulation based on a small sample of measured tag waveforms. The performance evaluation results not only

  12. Police interviewing and interrogation of juvenile suspects: a descriptive examination of actual cases.

    Science.gov (United States)

    Cleary, Hayley M D

    2014-06-01

    Although empirical attention to police interrogation has gained traction in recent years, comparatively few studies have examined interrogation of juvenile suspects, and virtually none have examined actual interrogations. Despite a growing literature on youths' interrogation-related capacities, we still know very little about what actually transpires when police question youth. The present study examines electronically recorded police interviews with juveniles to describe the characteristics, processes, and outcomes that occur in actual juvenile interrogations, including interview duration, individuals present, and confessions. Fifty-seven electronic recordings from 17 police departments were analyzed using observational research software. The median juvenile interrogation lasted 46 min, though the range was extensive (6 min to nearly 5 hr). Youth frequently submitted to questioning without a parent or advocate present, and disruptions to the interview process were common. Interrogation outcomes varied and included full confessions, partially incriminating admissions, and denials of guilt. Results from this study provide context for interrogation research using other methods and suggest that youth may frequently consent to interrogation in the absence of important legal protections.

  13. 25 CFR 11.303 - Notification of rights prior to custodial interrogation.

    Science.gov (United States)

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false Notification of rights prior to custodial interrogation. 11.303 Section 11.303 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR LAW AND ORDER... to custodial interrogation. Prior to custodial interrogation, the suspect shall be advised of the...

  14. 29 CFR 18.611 - Mode and order of interrogation and presentation.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Mode and order of interrogation and presentation. 18.611... of interrogation and presentation. (a) Control by judge. The judge shall exercise reasonable control... interrogation and presentation effective for the ascertainment of the truth, (2) Avoid needless consumption of...

  15. A pilot study of implantable cardiac device interrogation by emergency department personnel.

    Science.gov (United States)

    Neuenschwander, James F; Hiestand, Brian C; Peacock, W Frank; Billings, John M; Sondrup, Cole; Hummel, John D; Abraham, William T

    2014-03-01

    Implanted devices (eg, pacemakers and defibrillators) provide valuable information and may be interrogated to obtain diagnostic information and to direct management. During admission to an emergency department (ED), significant time and cost are spent waiting for device manufacturer representatives or cardiologists to access the data. If ED personnel could safely interrogate implanted devices, more rapid disposition could occur, thus leading to potentially better outcomes at a reduced cost. This was a pilot study examining the feasibility of ED device interrogation. This was a prospective convenience sample study of patients presenting to the ED with any chief complaint and who had an implantable device capable of being interrogated by a Medtronic reader. After obtaining informed consent, study patients underwent device interrogation by ED research personnel. After reviewing the device data, the physician documented their opinions of the value of data in aiding care. Patients were followed up at intervals ranging from 30 days out to 1 year to determine adverse events relating to interrogation. Forty-four patients underwent device interrogation. Their mean age was 56 ± 14.7 years (range, 28-83), 75% (33/44) were male and 75% (33/44) were hospitalized from the ED. The interrogations took less than 10 minutes 89% of the time. In 60% of the cases, ED physicians reported the data-assisted patient care. No adverse events were reported relating to the ED interrogations. In this pilot study, we found that ED personnel can safely and quickly interrogate implantable devices to obtain potentially useful clinical data.

  16. Innocence and resisting confession during interrogation: effects on physiologic activity.

    Science.gov (United States)

    Guyll, Max; Madon, Stephanie; Yang, Yueran; Lannin, Daniel G; Scherr, Kyle; Greathouse, Sarah

    2013-10-01

    Innocent suspects may not adequately protect themselves during interrogation because they fail to fully appreciate the danger of the situation. This experiment tested whether innocent suspects experience less stress during interrogation than guilty suspects, and whether refusing to confess expends physiologic resources. After experimentally manipulating innocence and guilt, 132 participants were accused and interrogated for misconduct, and then pressured to confess. Systolic and diastolic blood pressure (SBP, DBP), heart rate (HR), respiratory sinus arrhythmia (RSA), and preejection period (PEP) responses quantified stress reactions. As hypothesized, the innocent evidenced smaller stress responses to interrogation for SBP, DBP, HR, and RSA than did the guilty. Furthermore, innocents who refused to confess exhibited greater sympathetic nervous system activation, as evidenced by shorter PEPs, than did innocent or guilty confessors. These findings suggest that innocent suspects underestimate the threat of interrogation and that resisting pressures to confess can diminish suspects' physiologic resources and lead to false confessions. PsycINFO Database Record (c) 2013 APA, all rights reserved

  17. Fiber-MZI-based FBG sensor interrogation: comparative study with a CCD spectrometer.

    Science.gov (United States)

    Das, Bhargab; Chandra, Vikash

    2016-10-10

    We present an experimental comparative study of the two most commonly used fiber Bragg grating (FBG) sensor interrogation techniques: a charge-coupled device (CCD) spectrometer and a fiber Mach-Zehnder interferometer (F-MZI). Although the interferometric interrogation technique is historically known to offer the highest sensitivity measurements, very little information exists regarding how it compares with the current commercially available spectral-characteristics-based interrogation systems. It is experimentally established here that the performance of a modern-day CCD spectrometer interrogator is very close to a F-MZI interrogator with the capability of measuring Bragg wavelength shifts with sub-picometer-level accuracy. The results presented in this research study can further be used as a guideline for choosing between the two FBG sensor interrogator types for small-amplitude dynamic perturbation measurements down to nano-level strain.

  18. Investigation of active interrogation techniques to detect special nuclear material in maritime environments: Boarded search of a cargo container ship

    International Nuclear Information System (INIS)

    Grogan, Brandon R.; Henkel, James J.; Johnson, Jeffrey O.; Mihalczo, John T.; Miller, Thomas M.; Patton, Bruce W.

    2013-01-01

    The detonation of a terrorist nuclear weapon in the United States would result in the massive loss of life and grave economic damage. Even if a device was not detonated, its known or suspected presence aboard a cargo container ship in a U.S. port would have major economic and political consequences. One possible means to prevent this threat would be to board a ship at sea and search for the device before it reaches port. The scenario considered here involves a small Coast Guard team with strong intelligence boarding a container ship to search for a nuclear device. Using active interrogation, the team would nonintrusively search a block of shipping containers to locate the fissile material. Potential interrogation source and detector technologies for the team are discussed. The methodology of the scan is presented along with a technique for calculating the required interrogation source strength using computer simulations. MCNPX was used to construct a computer model of a container ship, and several search scenarios were simulated. The results of the simulations are presented in terms of the source strength required for each interrogation scenario. Validation measurements were performed in order to scale these simulation results to expected performance. Interrogations through the short (2.4 m) axis of a standardized shipping container appear to be feasible given the entire range of container loadings tested. Interrogations through several containers at once or a single container through its long (12.2 m) axis do not appear to be viable with a portable interrogation system

  19. Investigation of active interrogation techniques to detect special nuclear material in maritime environments: Boarded search of a cargo container ship

    Energy Technology Data Exchange (ETDEWEB)

    Grogan, Brandon R., E-mail: groganbr@ornl.gov; Henkel, James J.; Johnson, Jeffrey O.; Mihalczo, John T.; Miller, Thomas M.; Patton, Bruce W.

    2013-12-01

    The detonation of a terrorist nuclear weapon in the United States would result in the massive loss of life and grave economic damage. Even if a device was not detonated, its known or suspected presence aboard a cargo container ship in a U.S. port would have major economic and political consequences. One possible means to prevent this threat would be to board a ship at sea and search for the device before it reaches port. The scenario considered here involves a small Coast Guard team with strong intelligence boarding a container ship to search for a nuclear device. Using active interrogation, the team would nonintrusively search a block of shipping containers to locate the fissile material. Potential interrogation source and detector technologies for the team are discussed. The methodology of the scan is presented along with a technique for calculating the required interrogation source strength using computer simulations. MCNPX was used to construct a computer model of a container ship, and several search scenarios were simulated. The results of the simulations are presented in terms of the source strength required for each interrogation scenario. Validation measurements were performed in order to scale these simulation results to expected performance. Interrogations through the short (2.4 m) axis of a standardized shipping container appear to be feasible given the entire range of container loadings tested. Interrogations through several containers at once or a single container through its long (12.2 m) axis do not appear to be viable with a portable interrogation system.

  20. Battery-less wireless interrogation of microstrip patch antenna for strain sensing

    International Nuclear Information System (INIS)

    Xu, X; Huang, H

    2012-01-01

    This paper presents a battery-less wireless interrogation system that can measure the resonant frequency of a microstrip patch antenna with a fine resolution. Since the antenna resonant frequency is sensitive to strain-induced deformations, wireless interrogation of the antenna sensor for strain measurement was demonstrated. By implementing a microwatt impedance switching circuit at the sensor node, the antenna backscattering is amplitude modulated at the sensor node so that it can be separated from the structural backscattering at the interrogator. The sensor node can be powered by a small photocell and thus achieve battery-less operation. The operating principle of the wireless interrogation system is first described, followed by the implementation and characterization of the wireless interrogation system. The antenna resonant frequency shifts were correlated to the applied strains through a static tensile experiment. An excellent agreement between the experimental results and the analytical prediction was obtained. A power transmission model was established and validated with experimental measurements. Based on this power transmission model, we estimated that the maximum interrogation distance of the wireless strain measurement system is 26 m. (paper)

  1. What do potential jurors know about police interrogation techniques and false confessions?

    Science.gov (United States)

    Leo, Richard A; Liu, Brittany

    2009-01-01

    Psychological police interrogation methods in America inevitably involve some level of pressure and persuasion to achieve their goal of eliciting confessions of guilt from custodial suspects. In this article, we surveyed potential jurors about their perceptions of a range of psychological interrogation techniques, the likelihood that such techniques would elicit a true confession from guilty suspects, and the likelihood that such techniques could elicit a false confession from innocent suspects. Participants recognized that these interrogation techniques may be psychologically coercive and may elicit true confessions, but believed that psychologically coercive interrogation techniques are not likely to elicit false confessions. The findings from this survey study indicate that potential jurors believe that false confessions are both counter- intuitive and unlikely, even in response to psychologically coercive interrogation techniques that have been shown to lead to false confessions from the innocent. This study provides empirical support for the idea that expert witnesses may helpfully inform jurors about the social science research on psychologically coercive interrogation methods and how and why such interrogation techniques can lead to false confessions. (c) 2009 John Wiley & Sons, Ltd.

  2. Rattling nucleons: New developments in active interrogation of special nuclear material

    International Nuclear Information System (INIS)

    Runkle, Robert C.; Chichester, David L.; Thompson, Scott J.

    2012-01-01

    Active interrogation is a vigorous area of research and development due to its promise of offering detection and characterization capabilities of special nuclear material in environments where passive detection fails. The primary value added by active methods is the capability to penetrate shielding - special nuclear material itself, incidental materials, or intentional shielding - and advocates hope that active interrogation will provide a solution to the problem of detecting shielded uranium, which is at present the greatest obstacle to interdiction efforts. The technique also provides a unique benefit for quantifying nuclear material in high background-radiation environments, an area important for nuclear material safeguards and material accountancy. Progress has been made in the field of active interrogation on several fronts, most notably in the arenas of source development, systems integration, and the integration and exploitation of multiple fission and non-fission signatures. But penetration of interrogating radiation often comes at a cost, not only in terms of finance and dose but also in terms of induced backgrounds, system complexity, and extended measurement times (including set up and acquisition). These costs make the calculus for deciding to implement active interrogation more subtle than may be apparent. The purpose of this review is thus to examine existing interrogation methods, compare and contrast their attributes and limitations, and identify missions where active interrogation may hold the most promise.

  3. Interrogation: General vs. Local.

    Science.gov (United States)

    Johnson, Jeannette

    This paper proposes a set of hypotheses on the nature of interrogration as a possible language universal. Examples and phrase structure rules and diagrams are given. Examining Tamazight and English, genetically unrelated languages with almost no contact, the author distinguishes two types of interrogation: (1) general, querying acceptability to…

  4. Postmortem ICD interrogation in mode of death classification.

    Science.gov (United States)

    Nikolaidou, Theodora; Johnson, Miriam J; Ghosh, Justin M; Marincowitz, Carl; Shah, Saumil; Lammiman, Michael J; Schilling, Richard J; Clark, Andrew L

    2018-04-01

    The definition of sudden death due to arrhythmia relies on the time interval between onset of symptoms and death. However, not all sudden deaths are due to arrhythmia. In patients with an implantable cardioverter defibrillator (ICD), postmortem device interrogation may help better distinguish the mode of death compared to a time-based definition alone. This study aims to assess the proportion of "sudden" cardiac deaths in patients with an ICD that have confirmed arrhythmia. We conducted a literature search for studies using postmortem ICD interrogation and a time-based classification of the mode of death. A modified QUADAS-2 checklist was used to assess risk of bias in individual studies. Outcome data were pooled where sufficient data were available. Our search identified 22 studies undertaken between 1982 and 2015 with 23,600 participants. The pooled results (excluding studies with high risk of bias) suggest that ventricular arrhythmias are present at the time of death in 76% of "sudden" deaths (95% confidence interval [CI] 67-85; range 42-88). Postmortem ICD interrogation identifies 24% of "sudden" deaths to be nonarrhythmic. Postmortem device interrogation should be considered in all cases of unexplained sudden cardiac death. © 2018 Wiley Periodicals, Inc.

  5. Some Semantic Properties of Romanian Interrogatives: "Care" and "Cine."

    Science.gov (United States)

    Vasiliu, E.

    The aim of this paper is to account for some semantic properties of Romanian interrogatives "ce" and "cine" by establishing some definite correlations between various contextual restrictions governing the use of these interrogative particles and the "meaning" which might be assigned to each of these particles in any…

  6. Modeling and Interrogative Strategies.

    Science.gov (United States)

    Denney, Douglas R.

    Three studies to determine the effects of adult models on interrogative strategies of children (ages 6-11) are reviewed. Two issues are analyzed: (1) the comparative effectiveness of various types of modeling procedures for changing rule-governed behaviors, and (2) the interaction between observational learning and the developmental level of the…

  7. Utilization of the Tango beta-arrestin recruitment technology for cell-based EDG receptor assay development and interrogation.

    Science.gov (United States)

    Wetter, Justin A; Revankar, Chetana; Hanson, Bonnie J

    2009-10-01

    Cellular assay development for the endothelial differentiation gene (EDG) family of G-protein-coupled receptors (GPCRs) and related lysophospholipid (LP) receptors is complicated by endogenous receptor expression and divergent receptor signaling. Endogenously expressed LP receptors exist in most tissue culture cell lines. These LP receptors, along with other endogenously expressed GPCRs, contribute to off-target signaling that can complicate interpretation of second-messenger-based cellular assay results. These receptors also activate a diverse and divergent set of cellular signaling pathways, necessitating the use of a variety of assay formats with mismatched procedures and functional readouts. This complicates examination and comparison of these receptors across the entire family. The Tango technology uses the conserved beta-arrestin-dependent receptor deactivation process to allow interrogation of the EDG and related receptors with a single functional assay. This method also isolates the target receptor signal, allowing the use of tissue culture cell lines regardless of their endogenous receptor expression. The authors describe the use of this technique to build cell-based receptor-specific assays for all 8 members of the EDG receptor family as well as the related LPA receptors GPR23, GPR92, and GPR87. In addition, they demonstrate the value of this technology for identification and investigation of functionally selective receptor compounds as demonstrated by the immunosuppressive compound FtY720-P and its action at the EDG(1) and EDG(3) receptors.

  8. Interrogative suggestibility, confabulation, and acquiescence in people with mild learning disabilities (mental handicap): implications for reliability during police interrogations.

    Science.gov (United States)

    Clare, I C; Gudjonsson, G H

    1993-09-01

    In order to assess a criminal suspect's ability to make a reliable statement, performance on three measures--interrogative suggestibility, confabulation and acquiescence--may be used. This paper presents preliminary data on these measures for people with mild learning disabilities (Full Scale IQ [FSIQ]: 57-75). It was found that they were more suggestible than their average ability counterparts (FSIQ: 83-111) because they were much more susceptible to 'leading questions'. They also confabulated more and were more acquiescent. Overall, the data emphasized their potential vulnerability to giving erroneous testimony during interrogations.

  9. Catching the Cyber Spy: ARL's Interrogator

    National Research Council Canada - National Science Library

    Long, Kerry S

    2004-01-01

    The U.S. Army Research Laboratory has designed a network-based intrusion detection framework, Interrogator, which addresses the constantly changing threat environment that Department of Defense networks...

  10. Reduced representation approaches to interrogate genome diversity in large repetitive plant genomes.

    Science.gov (United States)

    Hirsch, Cory D; Evans, Joseph; Buell, C Robin; Hirsch, Candice N

    2014-07-01

    Technology and software improvements in the last decade now provide methodologies to access the genome sequence of not only a single accession, but also multiple accessions of plant species. This provides a means to interrogate species diversity at the genome level. Ample diversity among accessions in a collection of species can be found, including single-nucleotide polymorphisms, insertions and deletions, copy number variation and presence/absence variation. For species with small, non-repetitive rich genomes, re-sequencing of query accessions is robust, highly informative, and economically feasible. However, for species with moderate to large sized repetitive-rich genomes, technical and economic barriers prevent en masse genome re-sequencing of accessions. Multiple approaches to access a focused subset of loci in species with larger genomes have been developed, including reduced representation sequencing, exome capture and transcriptome sequencing. Collectively, these approaches have enabled interrogation of diversity on a genome scale for large plant genomes, including crop species important to worldwide food security. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  11. Improving Reasoning and Recall: The Differential Effects of Elaborative Interrogation and Mnemonic Elaboration.

    Science.gov (United States)

    Scruggs, Thomas E.; And Others

    1993-01-01

    Fifty-three adolescents with learning disabilities or mild mental retardation were taught reasons for dinosaur extinction. Those taught in a mnemonic elaborative interrogation condition recalled more reasons than did students who received direct teaching. Students in elaborative interrogation and mnemonic elaborative interrogation groups recalled…

  12. Optogenetic interrogation of neural circuits: technology for probing mammalian brain structures

    Science.gov (United States)

    Zhang, Feng; Gradinaru, Viviana; Adamantidis, Antoine R; Durand, Remy; Airan, Raag D; de Lecea, Luis; Deisseroth, Karl

    2015-01-01

    Elucidation of the neural substrates underlying complex animal behaviors depends on precise activity control tools, as well as compatible readout methods. Recent developments in optogenetics have addressed this need, opening up new possibilities for systems neuroscience. Interrogation of even deep neural circuits can be conducted by directly probing the necessity and sufficiency of defined circuit elements with millisecond-scale, cell type-specific optical perturbations, coupled with suitable readouts such as electrophysiology, optical circuit dynamics measures and freely moving behavior in mammals. Here we collect in detail our strategies for delivering microbial opsin genes to deep mammalian brain structures in vivo, along with protocols for integrating the resulting optical control with compatible readouts (electrophysiological, optical and behavioral). The procedures described here, from initial virus preparation to systems-level functional readout, can be completed within 4–5 weeks. Together, these methods may help in providing circuit-level insight into the dynamics underlying complex mammalian behaviors in health and disease. PMID:20203662

  13. Recent advances in the prenatal interrogation of the human fetal genome.

    Science.gov (United States)

    Hui, Lisa; Bianchi, Diana W

    2013-02-01

    The amount of genetic and genomic information obtainable from the human fetus during pregnancy is accelerating at an unprecedented rate. Two themes have dominated recent technological advances in prenatal diagnosis: interrogation of the fetal genome in increasingly high resolution and the development of non-invasive methods of fetal testing using cell-free DNA in maternal plasma. These two areas of advancement have now converged with several recent reports of non-invasive assessment of the entire fetal genome from maternal blood. However, technological progress is outpacing the ability of the healthcare providers and patients to incorporate these new tests into existing clinical care, and further complicates many of the economic and ethical dilemmas in prenatal diagnosis. This review summarizes recent work in this field and discusses the integration of these new technologies into the clinic and society. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Are the American Psychological Association’s Detainee Interrogation Policies Ethical and Effective?

    Science.gov (United States)

    Pope, Kenneth S.

    2011-01-01

    After 9–11, the United States began interrogating detainees at settings such as Abu Ghraib, Bagram, and Guantanamo. The American Psychological Association (APA) supported psychologists’ involvement in interrogations, adopted formal policies, and made an array of public assurances. This article’s purpose is to highlight key APA decisions, policies, procedures, documents, and public statements in urgent need of rethinking and to suggest questions that may be useful in a serious assessment, such as, “However well intended, were APA’s interrogation policies ethically sound?”; “Were they valid, realistic, and able to achieve their purpose?”; “Were other approaches available that would address interrogation issues more directly, comprehensively, and actively, that were more ethically and scientifically based, and that would have had a greater likelihood of success?”; and “Should APA continue to endorse its post-9–11 detainee interrogation policies?” PMID:22096660

  15. On velocity space interrogation regions of fast-ion collective Thomson scattering at ITER

    DEFF Research Database (Denmark)

    Salewski, Mirko; Nielsen, Stefan Kragh; Bindslev, Henrik

    2011-01-01

    the collective scattering in well-defined regions in velocity space, here dubbed interrogation regions. Since the CTS instrument measures entire spectra of scattered radiation, many different interrogation regions are probed simultaneously. We here give analytic expressions for weight functions describing...... the interrogation regions, and we show typical interrogation regions of the proposed ITER CTS system. The backscattering system with receivers on the low-field side is sensitive to fast ions with pitch |p| = |v/v| ... scattering system with receivers on the high-field side would be sensitive to co- and counter-passing fast ions in narrow interrogation regions with pitch |p| > 0.6–0.8. Additionally, we use weight functions to reconstruct 2D fast-ion distribution functions, given two projected 1D velocity distribution...

  16. Lies and coercion: why psychiatrists should not participate in police and intelligence interrogations.

    Science.gov (United States)

    Janofsky, Jeffrey S

    2006-01-01

    Police interrogators routinely use deceptive techniques to obtain confessions from criminal suspects. The United States Executive Branch has attempted to justify coercive interrogation techniques in which physical or mental pain and suffering may be used during intelligence interrogations of persons labeled unlawful combatants. It may be appropriate for law enforcement, military, or intelligence personnel who are not physicians to use such techniques. However, forensic psychiatry ethical practice requires honesty, striving for objectivity, and respect for persons. Deceptive and coercive interrogation techniques violate these moral values. When a psychiatrist directly uses, works with others who use, or trains others to use deceptive or coercive techniques to obtain information in police, military, or intelligence interrogations, the psychiatrist breaches basic principles of ethics.

  17. Dual reference point temperature interrogating method for distributed temperature sensor

    International Nuclear Information System (INIS)

    Ma, Xin; Ju, Fang; Chang, Jun; Wang, Weijie; Wang, Zongliang

    2013-01-01

    A novel method based on dual temperature reference points is presented to interrogate the temperature in a distributed temperature sensing (DTS) system. This new method is suitable to overcome deficiencies due to the impact of DC offsets and the gain difference in the two signal channels of the sensing system during temperature interrogation. Moreover, this method can in most cases avoid the need to calibrate the gain and DC offsets in the receiver, data acquisition and conversion. An improved temperature interrogation formula is presented and the experimental results show that this method can efficiently estimate the channel amplification and system DC offset, thus improving the system accuracy. (letter)

  18. Enhancing the performance of a tensioned metastable fluid detector based active interrogation system for the detection of SNM in interrogation source in moderated/reflected geometries

    Science.gov (United States)

    Grimes, T. F.; Hagen, A. R.; Archambault, B. C.; Taleyarkhan, R. P.

    2018-03-01

    This paper describes the development of a SNM detection system for interrogating 1m3 cargos via the combination of a D-D neutron interrogation source (with and without reflectors) and tensioned metastable fluid detectors (TMFDs). TMFDs have been previously shown (Taleyarkhan et al., 2008; Grimes et al., 2015; Grimes and Taleyarkhan, 2016; Archambault et al., 2017; Hagen et al., 2016) to be capable of using Threshold Energy Neutron Analysis (TENA) techniques to reject the ∼2.45 MeV D-D interrogating neutrons while still remaining sensitive to >2.45 MeV neutrons resulting from fission in the target (HEU) material. In order to enhance the performance, a paraffin reflector was included around the accelerator head. This reflector was used to direct neutrons into the package to increase the fission signal, lower the energy of the interrogating neutrons to increase the fission cross-section with HEU, and, also to direct interrogating neutrons away from the detectors in order to enhance the required discrimination between interrogating and fission neutrons. Experiments performed with a 239 Pu-Be neutron source and MnO2 indicated that impressive performance gains could be made by placing a parabolic paraffin moderator between the interrogation source and an air-filled cargo container with HEU placed at the center. However, experiments with other cargo fillers (as specified in the well-known ANSI N42.41-2007 report), and with HEU placed in locations other than the center of the package indicated that other reflector geometries might be superior due to over-"focusing" and the increased solid angle effects due to the accommodation of the moderator geometry. The best performance for the worst case of source location and box fill was obtained by placing the reflector only behind the D-D neutron source rather than in front of it. Finally, it was shown that there could be significant gains in the ability to detect concealed SNM by operating the system in multiple geometric

  19. Subthreshold neutron interrogator for detection of radioactive materials

    Science.gov (United States)

    Evans, Michael L.; Menlove, Howard O.; Baker, Michael P.

    1980-01-01

    A device for detecting fissionable material such as uranium in low concentrations by interrogating with photoneutrons at energy levels below 500 keV, and typically about 26 keV. Induced fast neutrons having energies above 500 keV by the interrogated fissionable material are detected by a liquid scintillator or recoil proportional counter which is sensitive to the induced fast neutrons. Since the induced fast neutrons are proportional to the concentration of fissionable material, detection of induced fast neutrons indicate concentration of the fissionable material.

  20. Low-Cost Interrogation Technique for Dynamic Measurements with FBG-Based Devices.

    Science.gov (United States)

    Díaz, Camilo A R; Leitão, Cátia; Marques, Carlos A; Domingues, M Fátima; Alberto, Nélia; Pontes, Maria José; Frizera, Anselmo; Ribeiro, Moisés R N; André, Paulo S B; Antunes, Paulo F C

    2017-10-23

    Fiber Bragg gratings are widely used optical fiber sensors for measuring temperature and/or mechanical strain. Nevertheless, the high cost of the interrogation systems is the most important drawback for their large commercial application. In this work, an in-line Fabry-Perot interferometer based edge filter is explored in the interrogation of fiber Bragg grating dynamic measurements up to 5 kHz. Two devices an accelerometer and an arterial pulse wave probe were interrogated with the developed approach and the results were compared with a commercial interrogation monitor. The data obtained with the edge filter are in agreement with the commercial device, with a maximum RMSE of 0.05 being able to meet the requirements of the measurements. Resolutions of 3.6 pm and 2.4 pm were obtained, using the optical accelerometer and the arterial pulse wave probe, respectively.

  1. Long period grating based refractometer with polarization-sensitive interrogation

    International Nuclear Information System (INIS)

    Eftimov, T; Bock, W; Mikulic, P; Nikolova, K

    2010-01-01

    We propose a new scheme for the interrogation of long-period fiber gratings (LPGs) which makes use of their polarization properties. Polarization-sensitive interrogation was applied to detect changes due to changes of the external refractive index by using three wavelengths on the International Telecommunication Union (ITU) grid. We show that the new approach can allow for a greater sensitivity and can be used in combination with spectral multiplexing schemes

  2. 76 FR 44282 - Defense Federal Acquisition Regulation Supplement; Prohibition on Interrogation of Detainees by...

    Science.gov (United States)

    2011-07-25

    ...-AG88 Defense Federal Acquisition Regulation Supplement; Prohibition on Interrogation of Detainees by... prescribes policies prohibiting interrogation of detainees by contractor personnel, as required by section... ancillary positions, including as trainers of, and advisors to, interrogations, if the contractor personnel...

  3. Technologies for security, military police, and professional policing organizations: the Department of Energy perspective

    Science.gov (United States)

    Steele, Basil J.

    1997-01-01

    There are many emerging technologies that can be used to help the law enforcement community protect the public as well as public and private facilities against ever increasing threats to this country and its resources. These technologies include sensors, closed circuit television (CCTV), access control, contraband detection, communications, control and display, barriers, and various component and system modeling techniques. This paper will introduce some of the various technologies that have been examined for the Department of Energy that could be applied to various law enforcement applications. They include: scannerless laser radar; next generation security systems; response force video information helmet system; access delay technologies; rapidly deployable intrusion detection systems; cost risk benefit analysis.

  4. 75 FR 67632 - Defense Federal Acquisition Regulation Supplement; Prohibition on Interrogation of Detainees by...

    Science.gov (United States)

    2010-11-03

    ...-AG88 Defense Federal Acquisition Regulation Supplement; Prohibition on Interrogation of Detainees by... National Defense Authorization Act for Fiscal Year 2010 (Pub. L. 111-84) prohibits the interrogation of..., to add DFARS 237.173, Prohibition on Interrogation of Detainees by Contractor Personnel, adding a...

  5. Interrogation of an object for dimensional and topographical information

    Science.gov (United States)

    McMakin, Doug L [Richland, WA; Severtsen, Ronald H [Richland, WA; Hall, Thomas E [Richland, WA; Sheen, David M [Richland, WA

    2003-01-14

    Disclosed are systems, methods, devices, and apparatus to interrogate a clothed individual with electromagnetic radiation to determine one or more body measurements at least partially covered by the individual's clothing. The invention further includes techniques to interrogate an object with electromagnetic radiation in the millimeter and/or microwave range to provide a volumetric representation of the object. This representation can be used to display images and/or determine dimensional information concerning the object.

  6. Using Elaborative Interrogation Enhanced Worked Examples to Improve Chemistry Problem Solving

    Science.gov (United States)

    Pease, Rebecca Simpson

    2012-01-01

    Elaborative interrogation, which prompts students to answer why-questions placed strategically within informational text, has been shown to increase learning comprehension through reading. In this study, elaborative interrogation why-questions requested readers to explain why paraphrased statements taken from a reading were "true."…

  7. Advanced microwave/millimeter-wave imaging technology

    International Nuclear Information System (INIS)

    Shen, Zuowei; Yang, Lu; Luhmann, N.C. Jr.

    2007-01-01

    Millimeter wave technology advances have made possible active and passive millimeter wave imaging for a variety of applications including advanced plasma diagnostics, radio astronomy, atmospheric radiometry, concealed weapon detection, all-weather aircraft landing, contraband goods detection, harbor navigation/surveillance in fog, highway traffic monitoring in fog, helicopter and automotive collision avoidance in fog, and environmental remote sensing data associated with weather, pollution, soil moisture, oil spill detection, and monitoring of forest fires, to name but a few. The primary focus of this paper is on technology advances which have made possible advanced imaging and visualization of magnetohydrodynamic (MHD) fluctuations and microturbulence in fusion plasmas. Topics of particular emphasis include frequency selective surfaces, planar Schottky diode mixer arrays, electronically controlled beam shaping/steering arrays, and high power millimeter wave local oscillator and probe sources. (author)

  8. Narrowband interrogation of plasmonic optical fiber biosensors based on spectral combs

    Science.gov (United States)

    González-Vila, Álvaro; Kinet, Damien; Mégret, Patrice; Caucheteur, Christophe

    2017-11-01

    Gold-coated tilted fiber Bragg gratings can probe surface Plasmon polaritons with high resolution and sensitivity. In this work, we report two configurations to interrogate such plasmonic biosensors, with the aim of providing more efficient alternatives to the widespread spectrometer-based techniques. To this aim, the interrogation is based on measuring the optical power evolution of the cladding modes with respect to surrounding refractive index changes instead of computing their wavelength shift. Both setups are composed of a broadband source and a photodiode and enable a narrowband interrogation around the cladding mode that excites the surface Plasmon resonance. The first configuration makes use of a uniform fiber Bragg grating to filter the broadband response of the source in a way that the final interrogation is based on an intensity modulation measured in transmission. The second setup uses a uniform fiber grating too, but located beyond the sensor and acting as a selective optical mirror, so the interrogation is carried out in reflection. Both configurations are compared, showing interesting differential features. The first one exhibits a very high sensitivity while the second one has an almost temperature-insensitive behavior. Hence, the choice of the most appropriate method will be driven by the requirements of the target application.

  9. Nuclear materials identification by photon interrogation

    International Nuclear Information System (INIS)

    Pozzi, S.A.; Monville, M.; Padovani, E.

    2005-01-01

    We describe a preliminary modification to the Monte Carlo codes MCNP-X and MCNP-PoliMi that is aimed at simulating the neutron and photon field generated by interrogating fissile (and non-fissile) material with a high energy photon source. Photo-atomic and photo-nuclear collisions are modeled, with particular emphasis on the generation of secondary particles that are emitted as a result of these interactions. The simulations can be used to design and analyze measurements that are performed in a wide variety of scenarios. An application of the methodology to the interrogation of packages on a luggage belt conveyor is presented. Preliminary results show that it is possible to detect 5 Kg of highly enriched uranium in a package by measuring the correlation function between 2 detectors. This correlation function is based on the detection of prompt radiation from photonuclear events

  10. Revenge versus rapport: Interrogation, terrorism, and torture.

    Science.gov (United States)

    Alison, Laurence; Alison, Emily

    2017-04-01

    This review begins with the historical context of harsh interrogation methods that have been used repeatedly since the Second World War. This is despite the legal, ethical and moral sanctions against them and the lack of evidence for their efficacy. Revenge-motivated interrogations (Carlsmith & Sood, 2009) regularly occur in high conflict, high uncertainty situations and where there is dehumanization of the enemy. These methods are diametrically opposed to the humanization process required for adopting rapport-based methods-for which there is an increasing corpus of studies evidencing their efficacy. We review this emerging field of study and show how rapport-based methods rely on building alliances and involve a specific set of interpersonal skills on the part of the interrogator. We conclude with 2 key propositions: (a) for psychologists to firmly maintain the Hippocratic Oath of "first do no harm," irrespective of perceived threat and uncertainty, and (b) for wider recognition of the empirical evidence that rapport-based approaches work and revenge tactics do not. Proposition (a) is directly in line with fundamental ethical principles of practice for anyone in a caring profession. Proposition (b) is based on the requirement for psychology to protect and promote human welfare and to base conclusions on objective evidence. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  11. Passive neutron interrogation in systems with a poorly characterized detection efficiency

    International Nuclear Information System (INIS)

    Dubi, Chen; Oster, Elad; Ocherashvilli, Aharon; Pedersen, Bent; Hutszy, Janus

    2014-01-01

    Passive neutron interrogation for fissile mass estimation, relying on neutrons coming from spontaneous fission events, is considered a standard NDT procedure in the nuclear safeguard and safety community. Since most structure materials are (relatively) transparent to neutron radiation, passive neutron interrogation is considered highly effective in the analysis of dirty, poorly characterized samples. On the other hand, since a typical passive interrogation assembly is based on 3He detectors, neutrons from additional neutron sources (mainly (α,n) reactions and induced fissions in the tested sample) cannot be separated from the main spontaneous fission source through energetic spectral analysis. There for, applying the passive interrogation methods the implementation of Neutron Multiplicity Counting (NMC) methods for separation between the main fission source and the additional sources. Applying NMC methods requires a well characterized system, in the sense that both system die away time and detection efficiency must be well known (and in particular, independent of the tested sample)

  12. Interferometric interrogation of π-phase shifted fiber Bragg grating sensors

    Science.gov (United States)

    Srivastava, Deepa; Tiwari, Umesh; Das, Bhargab

    2018-03-01

    Interferometric interrogation technique realized for conventional fiber Bragg grating (FBG) sensors is historically known to offer the highest sensitivity measurements, however, it has not been yet explored for π-phase-shifted FBG (πFBG) sensors. This, we believe, is due to the complex nature of the reflection/transmission spectrum of a πFBG, which cannot be directly used for interferometric interrogation purpose. Therefore, we propose here an innovative as well as simple concept towards this direction, wherein, the transmission spectrum of a πFBG sensor is optically filtered using a specially designed fiber grating. The resulting filtered spectrum retains the entire characteristics of a πFBG sensor and hence the filtered spectrum can be interrogated with interferometric principles. Furthermore, due to the extremely narrow transmission notch of a πFBG sensor, a fiber interferometer can be realized with significantly longer path difference. This leads to substantially enhanced detection limit as compared to sensors based on a regular FBG of similar length. Theoretical analysis demonstrates that high resolution weak dynamic strain measurement down to 4 pε /√{ Hz } is easily achievable. Preliminary experimental results are also presented as proof-of-concept of the proposed interrogation principle.

  13. "Enhanced" interrogation of detainees: do psychologists and psychiatrists participate?

    Science.gov (United States)

    Halpern, Abraham L; Halpern, John H; Doherty, Sean B

    2008-09-25

    After revelations of participation by psychiatrists and psychologists in interrogation of prisoners at Guantánamo Bay and Central Intelligence Agency secret detention centers, the American Psychiatric Association and the American Psychological Association adopted Position Statements absolutely prohibiting their members from participating in torture under any and all circumstances, and, to a limited degree, forbidding involvement in interrogations. Some interrogations utilize very aggressive techniques determined to be torture by many nations and organizations throughout the world. This paper explains why psychiatrists and psychologists involved in coercive interrogations violate the Geneva Conventions and the laws of the United States. Whether done with ignorance of professional ethical obligations or not, these psychiatrists and psychologists have crossed an ethical barrier that may best be averted from re-occurring by teaching medical students and residents in all medical specialties about the ethics principles stemming from the 1946-1947 Nuremberg trials and the Geneva Conventions, together with the Ethics Codes of the World Medical Association and the American Medical Association; and, with regard to psychiatric residents and psychological trainees, by the teaching about The Principles of Medical Ethics With Annotations Especially Applicable to Psychiatry and the Ethical Principles of Psychologists and Code of Conduct, respectively. In this way, all physicians and psychologists will clearly understand that they have an absolute moral obligation to "First, do no harm" to the human beings they professionally encounter.

  14. Active-interrogation measurements of fast neutrons from induced fission in low-enriched uranium

    International Nuclear Information System (INIS)

    Dolan, J.L.; Marcath, M.J.; Flaska, M.; Pozzi, S.A.; Chichester, D.L.; Tomanin, A.; Peerani, P.

    2014-01-01

    A detection system was designed with MCNPX-PoliMi to measure induced-fission neutrons from U-235 and U-238 using active interrogation. Measurements were then performed with this system at the Joint Research Centre in Ispra, Italy on low-enriched uranium samples. Liquid scintillators measured induced fission neutrons to characterize the samples in terms of their uranium mass and enrichment. Results are presented to investigate and support the use of organic liquid scintillators with active interrogation techniques to characterize uranium containing materials. -- Highlights: • We studied low-enriched uranium using active-interrogation experiments including a deuterium–tritium neutron generator and an americium–lithium isotopic neutron source. • Liquid scintillators measured induced-fission neutrons from the active-interrogation methods. • Fast-neutron (DT) and thermal-neutron (Am–Li) interrogation resulted in the measurement of trends in uranium mass and 235 U enrichment respectively. • MCNPX-PoliMi, the Monte Carlo transport code, simulated the measured induced-fission neutron trends in the liquid scintillators

  15. Active-interrogation measurements of fast neutrons from induced fission in low-enriched uranium

    Energy Technology Data Exchange (ETDEWEB)

    Dolan, J.L., E-mail: jldolan@umich.edu [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Marcath, M.J.; Flaska, M.; Pozzi, S.A. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Chichester, D.L. [Idaho National Laboratory, Idaho Falls, ID 83415 (United States); Tomanin, A.; Peerani, P. [European Commission, Joint Research Centre, Institute for Transuranium Elements, Ispra (Italy)

    2014-02-21

    A detection system was designed with MCNPX-PoliMi to measure induced-fission neutrons from U-235 and U-238 using active interrogation. Measurements were then performed with this system at the Joint Research Centre in Ispra, Italy on low-enriched uranium samples. Liquid scintillators measured induced fission neutrons to characterize the samples in terms of their uranium mass and enrichment. Results are presented to investigate and support the use of organic liquid scintillators with active interrogation techniques to characterize uranium containing materials. -- Highlights: • We studied low-enriched uranium using active-interrogation experiments including a deuterium–tritium neutron generator and an americium–lithium isotopic neutron source. • Liquid scintillators measured induced-fission neutrons from the active-interrogation methods. • Fast-neutron (DT) and thermal-neutron (Am–Li) interrogation resulted in the measurement of trends in uranium mass and {sup 235}U enrichment respectively. • MCNPX-PoliMi, the Monte Carlo transport code, simulated the measured induced-fission neutron trends in the liquid scintillators.

  16. Optimization of periodical interrogation of transducers of radioisotope measuring systems

    International Nuclear Information System (INIS)

    Ivashchenko, A.S.; Kaznakov, V.P.; Korolev, V.M.

    1978-01-01

    Certain methods are examined of optimizing periodic interrogation of sensors connected in a definite sequence to device for data processing in a system for controlling production processes. It is shown that in designing multiinput radioisotope measurement systems with a centralized data processing, the choice of the method of organizing periodic interrogation should be made with account for the conditions existing in each specific case

  17. Rheo: Japanese sound art interrogating digital mediality

    Directory of Open Access Journals (Sweden)

    Vandsø Anette

    2014-12-01

    Full Text Available The article asks in what way the Japanese sound artist, Ryoichi Kurokawa’s audiovisual installation, Rheo: 5 Horisonz (2010, is “digital.” Using professor Lars Elleström’s concept of “mediality,” the main claim in this article is that Rheo not only uses digital technology but also interrogates digital mediality as such. This argument is pursued in an analysis of Rheo that draws in various descriptions of digital media by N. Catherine Hayles, Lev Manovic, Bolter, and Grusin among other. The article will show how the critical potential in Rheo is directed both towards digital media as a language (Meyrowitz (or a place for representation and towards the digital as a milieu (Meyrowitz or as our culture (Gere. The overall goal of the article is not just analyse this singular art work, but also to show how such a sound art work can contribute to our understanding of our own contemporary culture as a digital culture.

  18. Active, Non-Intrusive Inspection Technologies for Homeland Defense

    International Nuclear Information System (INIS)

    James L. Jones

    2003-01-01

    Active, non-intrusive inspection or interrogation technologies have been used for 100 years - with the primary focus being radiographic imaging. During the last 50 years, various active interrogation systems have been investigated and most have revealed many unique and interesting capabilities and advantages that have already benefited the general public. Unfortunately, except for medical and specific industrial applications, these unique capabilities have not been widely adopted, largely due to the complexity of the technology, the overconfident reliance on passive detection systems to handle most challenges, and the unrealistic public concerns regarding radiation safety issues for a given active inspection deployment. The unique homeland security challenges facing the United States today are inviting more ''out-of-the-box'' solutions and are demanding the effective technological solutions that only active interrogation systems can provide. While revolutionary new solutions are always desired, these technology advancements are rare, and when found, usually take a long time to fully understand and implement for a given application. What's becoming more evident is that focusing on under-developed, but well-understood, active inspection technologies can provide many of the needed ''out-of-the-box'' solutions. This paper presents a brief historical overview of active interrogation. It identifies some of the major homeland defense challenges being confronted and the commercial and research technologies presently available and being pursued. Finally, the paper addresses the role of the Idaho National Engineering and Environmental Laboratory and its partner, the Idaho Accelerator Center at Idaho State University, in promoting and developing active inspection technologies for homeland defense

  19. Natural syntax : English interrogative main clauses

    Directory of Open Access Journals (Sweden)

    Janez Oresnik

    2007-12-01

    Full Text Available Natural Syntax is a developing deductive theory, a branch of Naturalness Theory. The naturalnessjudgements are couched in naturalness scales, whichfollow from the basic parameters (or «axioms» listed at the beginning of the paper. The predictions of the theory are calculated in deductions, whose chief components are apair of naturalness scales and the rules governing the alignment of corresponding naturalness values. Parallel and chiastic alignments are distinguished, in complementary distribution. Chiastic alignment is mandatory in deductions limited to unnatural environments. The paper deals with English interrogative main clauses. Within these, only the interrogatives containing wh-words exclusively insitu constitute an extremely unnatural environment and require chiastic alignment. Otherwiseparallel alignment is used. Earlier publications on Natural Syntax: Kavcic 2005a,b, Oresnik 1999, 2000a,b, 200la-f   2002, 2003a-c, 2002/03, 2004. This list cites only works written in English.

  20. Progress in miniaturization of a multichannel optical fiber Bragg grating sensor interrogator

    Science.gov (United States)

    Lopatin, Craig M.; Mahmood, Shah; Mendoza, Edgar; Moslehi, Behzad; Black, Richard; Chau, Kelvin; Oblea, Levy

    2007-07-01

    An effort to develop a miniaturized multichannel optical fiber Bragg grating sensor interrogator was initiated in 2006 under the Small Business Innovative Research (SBIR) program. The goal was to develop an interrogator that would be sufficiently small and light to be incorporated into a health monitoring system for use on tactical missiles. Two companies, Intelligent Fiber Optic Systems Corporation (IFOS) and Redondo Optics, were funded in Phase I, and this paper describes the prototype interrogators that were developed. The two companies took very different approaches: IFOS focused on developing a unit that would have a high channel count and high resolution, using off-the-shelf components, while Redondo Optics chose to develop a unit that would be very small and lightweight, using custom designed integrated optical chips. It is believed that both approaches will result in interrogators that will be significantly small, lighter, and possibly even more precise than what is currently commercially available. This paper will also briefly describe some of the sensing concepts that may be used to interrogate the health of the solid rocket motors used in many missile systems. The sponsor of this program was NAVAIR PMA 280.

  1. Diagnostic yield of device interrogation in the evaluation of syncope in an elderly population.

    Science.gov (United States)

    D'Angelo, Robert N; Pickett, Christopher C

    2017-06-01

    Device interrogation has become a standard part of the syncope evaluation for patients admitted with permanent pacemakers (PPM) or implantable cardiac defibrillators (ICD), although few studies have shown interrogation yields clinically useful data. The purpose of this study is to determine the diagnostic yield of device interrogation as well as other commonly performed tests in the workup of unexplained syncope in patients with previously implanted PPMs or ICDs. We retrospectively reviewed records of 88 patients admitted to our medical center for syncope with previously implanted pacemakers between January 1, 2005 and January 1, 2015 using ICD-9 billing data. Pacemaker interrogation demonstrated an arrhythmia as the cause for syncope in 4 patients (4%) and evidence of device failure secondary to perforation in 1 patient (1%). The cause of syncope was unknown in 34 patients (39%). Orthostatic hypotension was the most commonly identified cause of syncope (26%), followed by vasovagal syncope (13%), autonomic dysfunction (5%), ventricular arrhythmia (3%), atrial arrhythmia (2%), congestive heart failure (2%), stroke (2%), and other less common causes (8%). History was the most important determinant of syncope (36%), followed by orthostatic vital signs (14%), device interrogations (4%), head CT (2%), and transthoracic echocardiogram (1%). Device interrogation is rarely useful for elucidating a cause of syncope without concerning physical exam, telemetry, or EKG findings. Interrogation may occasionally yield paroxysmal arrhythmias responsible for syncopal episode, but these rarely alter clinical outcomes. Interrogation appears to be more useful in patients with syncope after recent device placement. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  2. Micro elements for interrogating magnetoelastic sensors

    KAUST Repository

    Liang, Cai; Gooneratne, Chinthaka Pasan; Kosel, Jü rgen; Mathison, Leslie C.; Chin, Bryan

    2011-01-01

    and length. Planar structures of straight-line and rectangular spiral coil are designed, fabricated and tested to interrogate the resonant frequency of a magnetoelastic sensor. A sensor of 4 mm length is measured to have a resonant frequency of 551 kHz in air

  3. INL Active Interrogation Testing In Support of the GNEP Safeguards Campaign

    International Nuclear Information System (INIS)

    David L. Chichester

    2008-01-01

    Active interrogation, a measurement technique which uses a radiation source to probe materials and generate unique signatures useful for characterizing those materials, is a powerful tool for assaying special nuclear material. Work at Idaho National Laboratory (INL) in the area of active interrogation, using neutron and photon sources, has been under way for many years to develop methods for detecting and quantifying nuclear material for national and homeland security research areas. This research knowledge base is now being extended to address nuclear safeguards and process monitoring issues related to the Global Nuclear Energy Partnership (GNEP). As a first step in this area preliminary scoping studies have been performed to investigate the usefulness of using active neutron interrogation, with a low-power electronic neutron generator, to assay Department of Transportation 6M shipping drums containing uranium oxide fuel rodlets from INL's zero power physics reactor. Using the paired-counting technique during the die-away time period of interrogation, a lower detection limit of approximately 4.2 grams of enriched uranium (40% 235U) was calculated for a 40 minute measurement using a field portable 2.5 MeV neutron source and an array of 16 moderated helium-3 neutron tubes. Future work in this area, including the use of a more powerful neutron source and a better tailored detector array, would likely improve this limit to a much lower level. Further development work at INL will explore the applicability of active interrogation in association with the nuclear safeguards and process monitoring needs of the advanced GNEP facilities under consideration. This work, which will include both analyses and field demonstrations, will be performed in collaboration with colleagues at INL and elsewhere that have expertise in nuclear fuel reprocessing as well as active interrogation and its use for nuclear material analyses

  4. Technologies for security, military police and professional policing organizations, the Department of Energy perspective

    International Nuclear Information System (INIS)

    Steele, B.J.

    1996-01-01

    There are many technologies emerging from this decade that can be used to help the law enforcement community protect the public as well as public and private facilities against ever increasing threats to this country and its resources. These technologies include sensors, closed circuit television (CCTV), access control, contraband detection, communications, control and display, barriers, and various component and system modeling techniques. This paper will introduce some of the various technologies that have been examined for the Department of Energy that could be applied to various law enforcement applications. They include: (1) scannerless laser radar; (2) next generation security systems; (3) response force video information helmet system; (4) access delay technologies; (5) rapidly deployable intrusion detection systems; and (6) cost risk benefit analysis

  5. "Enhanced" interrogation of detainees: do psychologists and psychiatrists participate?

    Directory of Open Access Journals (Sweden)

    Halpern John H

    2008-09-01

    Full Text Available Abstract After revelations of participation by psychiatrists and psychologists in interrogation of prisoners at Guantánamo Bay and Central Intelligence Agency secret detention centers, the American Psychiatric Association and the American Psychological Association adopted Position Statements absolutely prohibiting their members from participating in torture under any and all circumstances, and, to a limited degree, forbidding involvement in interrogations. Some interrogations utilize very aggressive techniques determined to be torture by many nations and organizations throughout the world. This paper explains why psychiatrists and psychologists involved in coercive interrogations violate the Geneva Conventions and the laws of the United States. Whether done with ignorance of professional ethical obligations or not, these psychiatrists and psychologists have crossed an ethical barrier that may best be averted from re-occurring by teaching medical students and residents in all medical specialties about the ethics principles stemming from the 1946–1947 Nuremberg trials and the Geneva Conventions, together with the Ethics Codes of the World Medical Association and the American Medical Association; and, with regard to psychiatric residents and psychological trainees, by the teaching about The Principles of Medical Ethics With Annotations Especially Applicable to Psychiatry and the Ethical Principles of Psychologists and Code of Conduct, respectively. In this way, all physicians and psychologists will clearly understand that they have an absolute moral obligation to "First, do no harm" to the human beings they professionally encounter.

  6. Methods and systems using encapsulated tracers and chemicals for reservoir interrogation and manipulation

    Science.gov (United States)

    Roberts, Jeffery; Aines, Roger D; Duoss, Eric B; Spadaccini, Christopher M

    2014-11-04

    An apparatus, method, and system of reservoir interrogation. A tracer is encapsulating in a receptacle. The receptacle containing the tracer is injected into the reservoir. The tracer is analyzed for reservoir interrogation.

  7. High-Speed Interrogation for Large-Scale Fiber Bragg Grating Sensing.

    Science.gov (United States)

    Hu, Chenyuan; Bai, Wei

    2018-02-24

    A high-speed interrogation scheme for large-scale fiber Bragg grating (FBG) sensing arrays is presented. This technique employs parallel computing and pipeline control to modulate incident light and demodulate the reflected sensing signal. One Electro-optic modulator (EOM) and one semiconductor optical amplifier (SOA) were used to generate a phase delay to filter reflected spectrum form multiple candidate FBGs with the same optical path difference (OPD). Experimental results showed that the fastest interrogation delay time for the proposed method was only about 27.2 us for a single FBG interrogation, and the system scanning period was only limited by the optical transmission delay in the sensing fiber owing to the multiple simultaneous central wavelength calculations. Furthermore, the proposed FPGA-based technique had a verified FBG wavelength demodulation stability of ±1 pm without average processing.

  8. Active Interrogation of Sensitive Nuclear Material Using Laser Driven Neutron Beams

    International Nuclear Information System (INIS)

    Favalli, Andrea; Roth, Markus

    2015-01-01

    An investigation of the viability of a laser-driven neutron source for active interrogation is reported. The need is for a fast, movable, operationally safe neutron source which is energy tunable and has high-intensity, directional neutron production. Reasons for the choice of neutrons and lasers are set forth. Results from the interrogation of an enriched U sample are shown.

  9. Sequential interrogation of multiple FBG sensors using LPG modulation and an artificial neural network

    International Nuclear Information System (INIS)

    Basu, Mainak; Ghorai, S K

    2015-01-01

    Interrogating multiple fiber Bragg gratings (FBG) requires highly sensitive spectrum scanning equipment such as optical spectrum analyzers, tunable filters, acousto-optic tunable filters etc, which are expensive, bulky and time consuming. In this paper, we present a new approach for multiple FBG sensor interrogation using long-period gratings and an artificial neural network. The reflection spectra of the multiplexed FBGs are modulated by two long period gratings separately and the modulated optical intensities were detected by two photodetectors. The outputs of the detectors are then used as input in a previously trained artificial neural network to interrogate the FBG sensors. Simulations have been performed to determine the strain and wavelength shift using two and four sensors. The interrogation system has also been demonstrated experimentally for two sensors using simply supported beams in the range of 0–350 μstrain. The proposed interrogation scheme has been found to identify the perturbed FBG, and to determine strain and wavelength shift with reasonable accuracy. (paper)

  10. Microwave Wire Interrogation Method Mapping Pressure under High Temperatures

    Directory of Open Access Journals (Sweden)

    Xiaoyong Chen

    2017-12-01

    Full Text Available It is widely accepted that wireless reading for in-situ mapping of pressure under high-temperature environments is the most feasible method, because it is not subject to frequent heterogeneous jointing failures and electrical conduction deteriorating, or even disappearing, under heat load. However, in this article, we successfully demonstrate an in-situ pressure sensor with wire interrogation for high-temperature applications. In this proof-of-concept study of the pressure sensor, we used a microwave resonator as a pressure-sensing component and a microwave transmission line as a pressure characteristic interrogation tunnel. In the sensor, the line and resonator are processed into a monolith, avoiding a heterogeneous jointing failure; further, microwave signal transmission does not depend on electrical conduction, and consequently, the sensor does not suffer from the heat load. We achieve pressure monitoring under 400 °C when employing the sensor simultaneously. Our sensor avoids restrictions that exist in wireless pressure interrogations, such as environmental noise and interference, signal leakage and security, low transfer efficiency, and so on.

  11. Interrogative suggestibility and perceptual motor performance.

    Science.gov (United States)

    Gudjonsson, G H

    1984-04-01

    This study investigates the relationship between interrogative suggestibility, as measured by the Gudjonsson Suggestibility Scale, and Arrow-Dot scores. The tendency of subjects (25 men and 25 women, mean age 30.2 yr.) to alter their answers once interpersonal pressure had been applied correlated significantly with poor Arrow-Dot Ego functioning.

  12. Overcoming Innocents' Naiveté: Pre-interrogation Decision-making Among Innocent Suspects.

    Science.gov (United States)

    Scherr, Kyle C; Alberts, Kimberly M; Franks, Andrew S; Hawkins, Ian

    2016-07-01

    Suspects, especially innocent ones, are highly susceptible to waiving their interrogation rights. This research tested the ability of two strategies to overcome innocent suspects' willingness to waive their rights. One strategy was based on the social influence of scarcity (i.e., not constraining the pre-interrogation time limit). The other strategy focused on disrupting individuals' cognitive fluency during the decision-making process (i.e., violating their induced expectation of offering a waiver). Disrupting innocent individuals' cognitive fluency increased their willingness to invoke their rights and, notably, was not qualified by interactions with any other factors. However, scarcity did not influence individuals' pre-interrogation decision-making. Results also further established the association between innocent individuals' naïve mindset and their willingness to waive their rights - specifically, innocents' willingness to waive their rights increased with the strength of their just world beliefs. The theoretical and applied implications of these findings are discussed. The importance and benefit of reforming pre-interrogation protocols using fair and feasible strategies that would disrupt suspects' cognitive fluency are emphasized. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Wavelength interrogation of fiber Bragg grating sensors using tapered hollow Bragg waveguides.

    Science.gov (United States)

    Potts, C; Allen, T W; Azar, A; Melnyk, A; Dennison, C R; DeCorby, R G

    2014-10-15

    We describe an integrated system for wavelength interrogation, which uses tapered hollow Bragg waveguides coupled to an image sensor. Spectral shifts are extracted from the wavelength dependence of the light radiated at mode cutoff. Wavelength shifts as small as ~10  pm were resolved by employing a simple peak detection algorithm. Si/SiO₂-based cladding mirrors enable a potential operational range of several hundred nanometers in the 1550 nm wavelength region for a taper length of ~1  mm. Interrogation of a strain-tuned grating was accomplished using a broadband amplified spontaneous emission (ASE) source, and potential for single-chip interrogation of multiplexed sensor arrays is demonstrated.

  14. Fissile mass estimation by pulsed neutron source interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Israelashvili, I., E-mail: israelashvili@gmail.com [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel); Dubi, C.; Ettedgui, H.; Ocherashvili, A. [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel); Pedersen, B. [Nuclear Security Unit, Institute for Transuranium Elements, Joint Research Centre, Via E. Fermi, 2749, 21027 Ispra (Italy); Beck, A. [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel); Roesgen, E.; Crochmore, J.M. [Nuclear Security Unit, Institute for Transuranium Elements, Joint Research Centre, Via E. Fermi, 2749, 21027 Ispra (Italy); Ridnik, T.; Yaar, I. [Nuclear Research Center of the Negev, P.O.B 9001, Beer Sheva 84190 (Israel)

    2015-06-11

    Passive methods for detecting correlated neutrons from spontaneous fissions (e.g. multiplicity and SVM) are widely used for fissile mass estimations. These methods can be used for fissile materials that emit a significant amount of fission neutrons (like plutonium). Active interrogation, in which fissions are induced in the tested material by an external continuous source or by a pulsed neutron source, has the potential advantages of fast measurement, alongside independence of the spontaneous fissions of the tested fissile material, thus enabling uranium measurement. Until recently, using the multiplicity method, for uranium mass estimation, was possible only for active interrogation made with continues neutron source. Pulsed active neutron interrogation measurements were analyzed with techniques, e.g. differential die away analysis (DDA), which ignore or implicitly include the multiplicity effect (self-induced fission chains). Recently, both, the multiplicity and the SVM techniques, were theoretically extended for analyzing active fissile mass measurements, made by a pulsed neutron source. In this study the SVM technique for pulsed neutron source is experimentally examined, for the first time. The measurements were conducted at the PUNITA facility of the Joint Research Centre in Ispra, Italy. First promising results, of mass estimation by the SVM technique using a pulsed neutron source, are presented.

  15. Scalable interrogation: Eliciting human pheromone responses to deception in a security interview setting.

    Science.gov (United States)

    Stedmon, Alex W; Eachus, Peter; Baillie, Les; Tallis, Huw; Donkor, Richard; Edlin-White, Robert; Bracewell, Robert

    2015-03-01

    Individuals trying to conceal knowledge from interrogators are likely to experience raised levels of stress that can manifest itself across biological, physiological, psychological and behavioural factors, providing an opportunity for detection. Using established research paradigms an innovative scalable interrogation was designed in which participants were given a 'token' that represented information they had to conceal from interviewers. A control group did not receive a token and therefore did not have to deceive the investigators. The aim of this investigation was to examine differences between deceivers and truth-tellers across the four factors by collecting data for cortisol levels, sweat samples, heart-rate, respiration, skin temperature, subjective stress ratings and video and audio recordings. The results provided an integrated understanding of responses to interrogation by those actively concealing information and those acting innocently. Of particular importance, the results also suggest, for the first time in an interrogation setting, that stressed individuals may secrete a volatile steroid based marker that could be used for stand-off detection. The findings are discussed in relation to developing a scalable interrogation protocol for future research in this area. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  16. Low-cost interferometric TDM technology for dynamic sensing applications

    Science.gov (United States)

    Bush, Jeff; Cekorich, Allen

    2004-12-01

    A low-cost design approach for Time Division Multiplexed (TDM) fiber-optic interferometric interrogation of multi-channel sensor arrays is presented. This paper describes the evolutionary design process of the subject design. First, the requisite elements of interferometric interrogation are defined for a single channel sensor. The concept is then extended to multi-channel sensor interrogation implementing a TDM multiplex scheme where "traditional" design elements are utilized. The cost of the traditional TDM interrogator is investigated and concluded to be too high for entry into many markets. A new design approach is presented which significantly reduces the cost for TDM interrogation. This new approach, in accordance with the cost objectives, shows promise to bring this technology to within the threshold of commercial acceptance for a wide range of distributed fiber sensing applications.

  17. Technological advances for interrogating the human kinome.

    Science.gov (United States)

    Baharani, Akanksha; Trost, Brett; Kusalik, Anthony; Napper, Scott

    2017-02-08

    There is increasing appreciation among researchers and clinicians of the value of investigating biology and pathobiology at the level of cellular kinase (kinome) activity. Kinome analysis provides valuable opportunity to gain insights into complex biology (including disease pathology), identify biomarkers of critical phenotypes (including disease prognosis and evaluation of therapeutic efficacy), and identify targets for therapeutic intervention through kinase inhibitors. The growing interest in kinome analysis has fueled efforts to develop and optimize technologies that enable characterization of phosphorylation-mediated signaling events in a cost-effective, high-throughput manner. In this review, we highlight recent advances to the central technologies currently available for kinome profiling and offer our perspectives on the key challenges remaining to be addressed. © 2017 The Author(s); published by Portland Press Limited on behalf of the Biochemical Society.

  18. The interrogation decision-making model: A general theoretical framework for confessions.

    Science.gov (United States)

    Yang, Yueran; Guyll, Max; Madon, Stephanie

    2017-02-01

    This article presents a new model of confessions referred to as the interrogation decision-making model . This model provides a theoretical umbrella with which to understand and analyze suspects' decisions to deny or confess guilt in the context of a custodial interrogation. The model draws upon expected utility theory to propose a mathematical account of the psychological mechanisms that not only underlie suspects' decisions to deny or confess guilt at any specific point during an interrogation, but also how confession decisions can change over time. Findings from the extant literature pertaining to confessions are considered to demonstrate how the model offers a comprehensive and integrative framework for organizing a range of effects within a limited set of model parameters. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  19. Prosodic differences between declaratives and interrogatives in infant-directed speech.

    Science.gov (United States)

    Geffen, Susan; Mintz, Toben H

    2017-07-01

    In many languages, declaratives and interrogatives differ in word order properties, and in syntactic organization more broadly. Thus, in order to learn the distinct syntactic properties of the two sentence types, learners must first be able to distinguish them using non-syntactic information. Prosodic information is often assumed to be a useful basis for this type of discrimination, although no systematic studies of the prosodic cues available to infants have been reported. Analysis of maternal speech in three Standard American English-speaking mother-infant dyads found that polar interrogatives differed from declaratives on the patterning of pitch and duration on the final two syllables, but wh-questions did not. Thus, while prosody is unlikely to aid discrimination of declaratives from wh-questions, infant-directed speech provides prosodic information that infants could use to distinguish declaratives and polar interrogatives. We discuss how learners could leverage this information to identify all question forms, in the context of syntax acquisition.

  20. Suicidality and interrogative suggestibility.

    Science.gov (United States)

    Pritchard-Boone, Lea; Range, Lillian M

    2005-01-01

    All people are subject to memory suggestibility, but suicidal individuals may be especially so. The link between suicidality and suggestibility is unclear given mixed findings and methodological weaknesses of past research. To test the link between suicidality and interrogative suggestibility, 149 undergraduates answered questions about suicidal thoughts and reasons for living, and participated in a direct suggestibility procedure. As expected, suggestibility correlated with suicidality but accounted for little overall variance (4%). Mental health professionals might be able to take advantage of client suggestibility by directly telling suicidal persons to refrain from suicidal thoughts or actions.

  1. Optical measuring system with an interrogator and a polymer-based single-mode fibre optic sensor system

    DEFF Research Database (Denmark)

    2017-01-01

    The present invention relates to an optical measuring system comprising a polymer-based single-mode fibre-optic sensor system (102), an optical interrogator (101), and an optical arrangement (103) interconnecting the optical interrogator (101) and the polymer-based single-mode fibre-optic sensor...... system (102). The invention further relates to an optical interrogator adapted to be connected to a polymer-based single-mode fibre-optic sensor system via an optical arrangement. The interrogator comprises a broadband light source arrangement (104) and a spectrum analysing arrangement which receives...

  2. Resolution-improved in situ DNA hybridization detection based on microwave photonic interrogation.

    Science.gov (United States)

    Cao, Yuan; Guo, Tuan; Wang, Xudong; Sun, Dandan; Ran, Yang; Feng, Xinhuan; Guan, Bai-ou

    2015-10-19

    In situ bio-sensing system based on microwave photonics filter (MPF) interrogation method with improved resolution is proposed and experimentally demonstrated. A microfiber Bragg grating (mFBG) is used as sensing probe for DNA hybridization detection. Different from the traditional wavelength monitoring technique, we use the frequency interrogation scheme for resolution-improved bio-sensing detection. Experimental results show that the frequency shift of MPF notch presents a linear response to the surrounding refractive index (SRI) change over the range of 1.33 to 1.38, with a SRI resolution up to 2.6 × 10(-5) RIU, which has been increased for almost two orders of magnitude compared with the traditional fundamental mode monitoring technique (~3.6 × 10(-3) RIU). Due to the high Q value (about 27), the whole process of DNA hybridization can be in situ monitored. The proposed MPF-based bio-sensing system provides a new interrogation method over the frequency domain with improved sensing resolution and rapid interrogation rate for biochemical and environmental measurement.

  3. Development of active neutron interrogation techniques at Harwell

    International Nuclear Information System (INIS)

    Armitage, B.H.; Chard, P.M.J.; Packer, T.W.; Swinhoe, M.T.; Syme, D.B.

    1990-01-01

    Active neutron interrogation techniques capable of measuring the fissile content of a range of waste drum sizes and contents have been developed at Harwell. This paper describes measurements which have been made to investigate the behaviour of these assay systems for the difficult case of concreted waste in a heterogeneous matrix. The drums have been measured using a Cf shuffler and a differential die-away system, with supporting information obtained from a segmented gamma-scanner. Good correspondence has been observed between the two different neutron interrogation techniques. It was concluded that the measurement of highly heterogeneous wastes is likely to be more effective if calibration can be undertaken with representative artificial matrices. Further measurement and analysis remains to be undertaken

  4. Police training in interviewing and interrogation methods: A comparison of techniques used with adult and juvenile suspects.

    Science.gov (United States)

    Cleary, Hayley M D; Warner, Todd C

    2016-06-01

    Despite empirical progress in documenting and classifying various interrogation techniques, very little is known about how police are trained in interrogation methods, how frequently they use various techniques, and whether they employ techniques differentially with adult versus juvenile suspects. This study reports the nature and extent of formal (e.g., Reid Technique, PEACE, HUMINT) and informal interrogation training as well as self-reported technique usage in a diverse national sample (N = 340) of experienced American police officers. Officers were trained in a variety of different techniques ranging from comparatively benign pre-interrogation strategies (e.g., building rapport, observing body language or speech patterns) to more psychologically coercive techniques (e.g., blaming the victim, discouraging denials). Over half the sample reported being trained to use psychologically coercive techniques with both adults and juveniles. The majority (91%) receive informal, "on the job" interrogation training. Technique usage patterns indicate a spectrum of psychological intensity where information-gathering approaches were used most frequently and high-pressure tactics less frequently. Reid-trained officers (56%) were significantly more likely than officers without Reid training to use pre-interrogation and manipulation techniques. Across all analyses and techniques, usage patterns were identical for adult and juvenile suspects, suggesting that police interrogate youth in the same manner as adults. Overall, results suggest that training in specific interrogation methods is strongly associated with usage. Findings underscore the need for more law enforcement interrogation training in general, especially with juvenile suspects, and highlight the value of training as an avenue for reducing interrogation-induced miscarriages of justice. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  5. Implantable fiber-optic interface for parallel multisite long-term optical dynamic brain interrogation in freely moving mice

    Science.gov (United States)

    Doronina-Amitonova, L. V.; Fedotov, I. V.; Ivashkina, O. I.; Zots, M. A.; Fedotov, A. B.; Anokhin, K. V.; Zheltikov, A. M.

    2013-01-01

    Seeing the big picture of functional responses within large neural networks in a freely functioning brain is crucial for understanding the cellular mechanisms behind the higher nervous activity, including the most complex brain functions, such as cognition and memory. As a breakthrough toward meeting this challenge, implantable fiber-optic interfaces integrating advanced optogenetic technologies and cutting-edge fiber-optic solutions have been demonstrated, enabling a long-term optogenetic manipulation of neural circuits in freely moving mice. Here, we show that a specifically designed implantable fiber-optic interface provides a powerful tool for parallel long-term optical interrogation of distinctly separate, functionally different sites in the brain of freely moving mice. This interface allows the same groups of neurons lying deeply in the brain of a freely behaving mouse to be reproducibly accessed and optically interrogated over many weeks, providing a long-term dynamic detection of genome activity in response to a broad variety of pharmacological and physiological stimuli. PMID:24253232

  6. Real time interrogation technique for fiber Bragg grating enhanced fiber loop ringdown sensors array.

    Science.gov (United States)

    Zhang, Yunlong; Li, Ruoming; Shi, Yuechun; Zhang, Jintao; Chen, Xiangfei; Liu, Shengchun

    2015-06-01

    A novel fiber Bragg grating aided fiber loop ringdown (FLRD) sensor array and the wavelength-time multiplexing based interrogation technique for the FLRD sensors array are proposed. The interrogation frequency of the system is formulated and the interrelationships among the parameters of the system are analyzed. To validate the performance of the proposed system, a five elements array is experimentally demonstrated, and the system shows the capability of real time monitoring every FLRD element with interrogation frequency of 125.5 Hz.

  7. A high-temperature fiber sensor using a low cost interrogation scheme.

    Science.gov (United States)

    Barrera, David; Sales, Salvador

    2013-09-04

    Regenerated Fibre Bragg Gratings have the potential for high-temperature monitoring. In this paper, the inscription of Fibre Bragg Gratings (FBGs) and the later regeneration process to obtain Regenerated Fiber Bragg Gratings (RFBGs) in high-birefringence optical fiber is reported. The obtained RFBGs show two Bragg resonances corresponding to the slow and fast axis that are characterized in temperature terms. As the temperature increases the separation between the two Bragg resonances is reduced, which can be used for low cost interrogation. The proposed interrogation setup is based in the use of optical filters in order to convert the wavelength shift of each of the Bragg resonances into optical power changes. The design of the optical filters is also studied in this article. In first place, the ideal filter is calculated using a recursive method and defining the boundary conditions. This ideal filter linearizes the output of the interrogation setup but is limited by the large wavelength shift of the RFBG with temperature and the maximum attenuation. The response of modal interferometers as optical filters is also analyzed. They can be easily tuned shifting the optical spectrum. The output of the proposed interrogation scheme is simulated in these conditions improving the sensitivity.

  8. High performance multi-spectral interrogation for surface plasmon resonance imaging sensors.

    Science.gov (United States)

    Sereda, A; Moreau, J; Canva, M; Maillart, E

    2014-04-15

    Surface plasmon resonance (SPR) sensing has proven to be a valuable tool in the field of surface interactions characterization, especially for biomedical applications where label-free techniques are of particular interest. In order to approach the theoretical resolution limit, most SPR-based systems have turned to either angular or spectral interrogation modes, which both offer very accurate real-time measurements, but at the expense of the 2-dimensional imaging capability, therefore decreasing the data throughput. In this article, we show numerically and experimentally how to combine the multi-spectral interrogation technique with 2D-imaging, while finding an optimum in terms of resolution, accuracy, acquisition speed and reduction in data dispersion with respect to the classical reflectivity interrogation mode. This multi-spectral interrogation methodology is based on a robust five parameter fitting of the spectral reflectivity curve which enables monitoring of the reflectivity spectral shift with a resolution of the order of ten picometers, and using only five wavelength measurements per point. In fine, such multi-spectral based plasmonic imaging system allows biomolecular interaction monitoring in a linear regime independently of variations of buffer optical index, which is illustrated on a DNA-DNA model case. © 2013 Elsevier B.V. All rights reserved.

  9. A SYSTEMATIC APPROACH TO THE PSYCHOLOGICAL IMPACT OF THE INVESTIGATOR ON A PERSON BEING INTERROGATED

    Directory of Open Access Journals (Sweden)

    Ivan Cherevko

    2017-03-01

    Full Text Available The subject of the research is an interaction with a person being interrogated organized by an investigator with the use of his interests, needs and other individual-mental features, his reinforcement, which must be done through secretive, invisible influence in an organized situation encouraging to do deeds desirable for investigation. The object of the research is interrogation as the most psychologized investigative action. The methodological basis of the research is made by the systematic and logical approach aimed at neutralization of watchfulness of the interrogated, penetration into his inner world influencing both rational and irrational spheres of mental make-up, actualization of the unity of understanding and experience. In this research general scientific and specific scientific methods of cognition are used. General scientific methods of the research are represented by systemic structural, comparative, formal and legal, statistical methods. The approach to the psychological impact on a person being interrogated as a systemic phenomenon has enabled to develop a conceptual model presented in the form of a diagram made up of four blocks reflecting emotional background sources of interrogation procedures, the interrogated case, interaction and basic methods of psychological influence, the leading of which is persuasion. Suggestion is purposeful influence on feelings and volitional pressure acts as pressure maintenance, complementary, used depending on the situational behaviour of the interrogated. Methods of implementation of each of these methods of psychological influence are also considered in this article.

  10. Are the American Psychological Association's Detainee Interrogation Policies Ethical and Effective?: Key Claims, Documents, and Results.

    Science.gov (United States)

    Pope, Kenneth S

    2011-01-01

    After 9-11, the United States began interrogating detainees at settings such as Abu Ghraib, Bagram, and Guantanamo. The American Psychological Association (APA) supported psychologists' involvement in interrogations, adopted formal policies, and made an array of public assurances. This article's purpose is to highlight key APA decisions, policies, procedures, documents, and public statements in urgent need of rethinking and to suggest questions that may be useful in a serious assessment, such as, "However well intended, were APA's interrogation policies ethically sound?"; "Were they valid, realistic, and able to achieve their purpose?"; "Were other approaches available that would address interrogation issues more directly, comprehensively, and actively, that were more ethically and scientifically based, and that would have had a greater likelihood of success?"; and "Should APA continue to endorse its post-9-11 detainee interrogation policies?"

  11. A review of conventional explosives detection using active neutron interrogation

    International Nuclear Information System (INIS)

    Whetstone, Z.D.; Kearfott, K.J.

    2014-01-01

    Conventional explosives are relatively easy to obtain and may cause massive harm to people and property. There are several tools employed by law enforcement to detect explosives, but these can be subverted. Active neutron interrogation is a viable alternative to those techniques, and includes: fast neutron analysis, thermal neutron analysis, pulsed fast/thermal neutron analysis, neutron elastic scatter, and fast neutron radiography. These methods vary based on neutron energy and radiation detected. A thorough review of the principles behind, advantages, and disadvantages of the different types of active neutron interrogation is presented. (author)

  12. Simulation of path delay multiplexing-based Fourier transform spectrometer for fiber Bragg grating interrogation.

    Science.gov (United States)

    Chelliah, Pandian; Sahoo, Trilochan; Singh, Sheela; Sujatha, Annie

    2015-10-20

    A Fourier transform spectrometer (FTS) used for interrogating a fiber Bragg grating (FBG) consists of a scanning-type interferometer. The FTS has a broad wavelength range of operation and good multiplexing capability. However, it has poor wavelength resolution and interrogation speed. We propose a modification to the FTS using path delay multiplexing to improve the same. Using this method, spatial resolution and interrogation time can be improved by n times by using n path delays. In this paper, simulation results for n=2, 5 are shown.

  13. Neutron interrogation of actinides with a 17 MeV electron accelerator and first results from photon and neutron interrogation non-simultaneous measurements combination

    Energy Technology Data Exchange (ETDEWEB)

    Sari, A., E-mail: adrien.sari@cea.fr [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Carrel, F.; Lainé, F. [CEA, LIST, Laboratoire Capteurs et Architectures Electroniques, 91191 Gif-sur-Yvette Cedex (France); Lyoussi, A. [CEA, DEN, 13108 Saint-Paul-Lez-Durance Cedex (France)

    2013-10-01

    In this article, we demonstrate the feasibility of neutron interrogation using the conversion target of a 17 MeV linear electron accelerator as a neutron generator. Signals from prompt neutrons, delayed neutrons, and delayed gamma-rays, emitted by both uranium and plutonium samples were analyzed. First results from photon and neutron interrogation non-simultaneous measurements combination are also reported in this paper. Feasibility of this technique is shown in the frame of the measurement of uranium enrichment. The latter was carried out by combining detection of prompt neutrons from thermal fission and delayed neutrons from photofission, and by combining delayed gamma-rays from thermal fission and delayed gamma-rays from photofission.

  14. Lawfulness of Interrogation Techniques under the Geneva Conventions

    National Research Council Canada - National Science Library

    Elsea, Jennifer K

    2004-01-01

    Allegations of abuse of Iraqi prisoners by U.S. soldiers at the Abu Ghraib prison in Iraq have raised questions about the applicability of the law of war to interrogations for military intelligence purposes...

  15. Rheo: Japanese Sound Art Interrogating Digital Mediality

    DEFF Research Database (Denmark)

    Vandsø, Anette

    2014-01-01

    THe article asks in what way the Japanese sound artist Ryoichi Kurokawa's audiovisual installation Rheo 5 Horisonz (2010) is 'digital'. Using Professor Lars Elleströms concept of 'mediality, the main claim in this article is that Rheo no only uses digital tehcnology, but also interrogates digital...

  16. Noncontact power/interrogation system for smart structures

    Science.gov (United States)

    Spillman, William B., Jr.; Durkee, S.

    1994-05-01

    The field of smart structures has been largely driven by the development of new high performance designed materials. Use of these materials has been generally limited due to the fact that they have not been in use long enough for statistical data bases to be developed on their failure modes. Real time health monitoring is therefore required for the benefits of structures using these materials to be realized. In this paper a non-contact method of powering and interrogating embedded electronic and opto-electronic systems is described. The technique utilizes inductive coupling between external and embedded coils etched on thin electronic circuit cards. The technique can be utilized to interrogate embedded sensors and to provide > 250 mW for embedded electronics. The system has been successfully demonstrated with a number of composite and plastic materials through material thicknesses up to 1 cm. An analytical description of the system is provided along with experimental results.

  17. The phase interrogation method for optical fiber sensor by analyzing the fork interference pattern

    Science.gov (United States)

    Lv, Riqing; Qiu, Liqiang; Hu, Haifeng; Meng, Lu; Zhang, Yong

    2018-02-01

    The phase interrogation method for optical fiber sensor is proposed based on the fork interference pattern between the orbital angular momentum beam and plane wave. The variation of interference pattern with phase difference between the two light beams is investigated to realize the phase interrogation. By employing principal component analysis method, the features of the interference pattern can be extracted. Moreover, the experimental system is designed to verify the theoretical analysis, as well as feasibility of phase interrogation. In this work, the Mach-Zehnder interferometer was employed to convert the strain applied on sensing fiber to the phase difference between the reference and measuring paths. This interrogation method is also applicable for the measurements of other physical parameters, which can produce the phase delay in optical fiber. The performance of the system can be further improved by employing highlysensitive materials and fiber structures.

  18. Design of Interrogation Protocols for Radiation Dose Measurements Using Optically-Stimulated Luminescent Dosimeters.

    Science.gov (United States)

    Abraham, Sara A; Kearfott, Kimberlee J; Jawad, Ali H; Boria, Andrew J; Buth, Tobias J; Dawson, Alexander S; Eng, Sheldon C; Frank, Samuel J; Green, Crystal A; Jacobs, Mitchell L; Liu, Kevin; Miklos, Joseph A; Nguyen, Hien; Rafique, Muhammad; Rucinski, Blake D; Smith, Travis; Tan, Yanliang

    2017-03-01

    Optically-stimulated luminescent dosimeters are capable of being interrogated multiple times post-irradiation. Each interrogation removes a fraction of the signal stored within the optically-stimulated luminescent dosimeter. This signal loss must be corrected to avoid systematic errors in estimating the average signal of a series of optically-stimulated luminescent dosimeter interrogations and requires a minimum number of consecutive readings to determine an average signal that is within a desired accuracy of the true signal with a desired statistical confidence. This paper establishes a technical basis for determining the required number of readings for a particular application of these dosimeters when using certain OSL dosimetry systems.

  19. The Sociocultural Psychology as a Postformal Theory of Academic Achievement: Interrogating Formal Education

    Science.gov (United States)

    Sinha, Chetan

    2013-01-01

    The present paper interrogates the dominance of formal education. As formal education system relies on ability based academic achievement as a goal, exploring post-formal approaches, such as sociocultural notion of academic achievement is the hallmark of present paper. An attempt is made to interrogate the existing cultural dominance in formal…

  20. From third degree to third generation interrogation strategies: putting science into the art of criminal interviewing

    Science.gov (United States)

    2017-03-01

    tacitly suggest that a confession is the fastest and best way to end the interrogation .73 71 Ibid...Kelly, and Miller found approximately 45 percent of civilian interrogators use it as well.292 Because this percentage suggests the technique is...TO THIRD-GENERATION INTERROGATION STRATEGIES: PUTTING SCIENCE INTO THE ART OF CRIMINAL INTERVIEWING by Desmond S. O’Neill March 2017

  1. Ultrafast Fiber Bragg Grating Interrogation for Sensing in Detonation and Shock Wave Experiments.

    Science.gov (United States)

    Rodriguez, George; Gilbertson, Steve M

    2017-01-27

    Chirped fiber Bragg grating (CFBG) sensors coupled to high speed interrogation systems are described as robust diagnostic approaches to monitoring shock wave and detonation front propagation tracking events for use in high energy density shock physics applications. Taking advantage of the linear distributed spatial encoding of the spectral band in single-mode CFBGs, embedded fiber systems and associated photonic interrogation methodologies are shown as an effective approach to sensing shock and detonation-driven loading processes along the CFBG length. Two approaches, one that detects spectral changes in the integrated spectrum of the CFBG and another coherent pulse interrogation approach that fully resolves its spectral response, shows that 100-MHz-1-GHz interrogation rates are possible with spatial resolution along the CFBG in the 50 µm to sub-millimeter range depending on the combination of CFBG parameters (i.e., length, chirp rate, spectrum) and interrogator design specifics. Results from several dynamic tests are used to demonstrate the performance of these high speed systems for shock and detonation propagation tracking under strong and weak shock pressure loading: (1) linear detonation front tracking in the plastic bonded explosive (PBX) PBX-9501; (2) tracking of radial decaying shock with crossover to non-destructive CFBG response; (3) shock wave tracking along an aluminum cylinder wall under weak loading accompanied by dynamic strain effects in the CFBG sensor.

  2. Police reports of mock suspect interrogations: A test of accuracy and perception.

    Science.gov (United States)

    Kassin, Saul M; Kukucka, Jeff; Lawson, Victoria Z; DeCarlo, John

    2017-06-01

    A 2-phased experiment assessed the accuracy and completeness of police reports on mock interrogations and their effects on people's perceptions. In Phase 1, 16 experienced officers investigated a mock crime scene, interrogated 2 innocent suspects-1 described by the experimenter as more suspicious than the other-and filed an incident report. All 32 sessions were covertly recorded; the recordings were later used to assess the reports. In Phase 2, 96 lay participants were presented with a brief summary of the case and then either read 1 police report, read 1 verbatim interrogation transcript, or listened to an audiotape of a session. Results showed that (a) Police and suspects diverged in their perceptions of the interrogations; (b) Police committed frequent errors of omission in their reports, understating their use of confrontation, maximization, leniency, and false evidence; and (c) Phase 2 participants who read a police report, compared to those who read a verbatim transcript, perceived the process as less pressure-filled and were more likely to misjudge suspects as guilty. These findings are limited by the brevity and low-stakes nature of the task and by the fact that no significant effects were obtained for our suspicion manipulation, suggesting a need for more research. Limitations notwithstanding, this study adds to a growing empirical literature indicating the need for a requirement that all suspect interrogations be electronically recorded. To provide a more objective and accurate account of what transpired, this study also suggests the benefit of producing verbatim transcripts. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  3. Performance of a remote interrogation system for the in-hospital evaluation of cardiac implantable electronic devices.

    Science.gov (United States)

    Mittal, Suneet; Younge, Kevin; King-Ellison, Kelly; Hammill, Eric; Stein, Kenneth

    2016-08-01

    Patients with a cardiac implantable electronic device (CIED) often need device interrogation in an in-hospital environment. A diagnosis-only, remote interrogation device and process for CIED interrogation was developed to address this situation. Here, we describe our initial clinical experience with this system. The LATITUDE Consult Communicator is a stand-alone interrogation-only device used to read the patient's implanted CIED. Once retrieved, the data are securely transmitted via an analog phone line to a central server. The clinician can request a review of the transmitted data at any time. Following FDA approval, we determined the usage and performance of the system. Communicators (n = 53) were installed in 42 hospital facilities. The most common location was in the emergency department (n = 32, 60 %). There were 509 discreet transmissions, which were categorized as follows: no arrhythmia episodes in the past 72 h and no out of range measurements (n = 174, 34 %); arrhythmia episodes in past 72 h but no out of range measurements (n = 170, 33 %); and further review recommended (n = 130, 26 %). (In 35 [7 %] instances, interrogation without analysis was requested.) The further review interrogations were then sub-divided into those of a non-urgent and urgent nature. Overall, only 53 (10 %) of the 509 transmissions were classified as urgent. Clinicians had access to full technical consultation in ≤15 min in 89 % of instances. Our data demonstrate the feasibility of a new diagnosis-only, remote interrogation device and remote evaluation process for the interrogation of CIEDs in an in-hospital environment.

  4. FBG Interrogation Method with High Resolution and Response Speed Based on a Reflective-Matched FBG Scheme

    Science.gov (United States)

    Cui, Jiwen; Hu, Yang; Feng, Kunpeng; Li, Junying; Tan, Jiubin

    2015-01-01

    In this paper, a high resolution and response speed interrogation method based on a reflective-matched Fiber Bragg Grating (FBG) scheme is investigated in detail. The nonlinear problem of the reflective-matched FBG sensing interrogation scheme is solved by establishing and optimizing the mathematical model. A mechanical adjustment to optimize the interrogation method by tuning the central wavelength of the reference FBG to improve the stability and anti-temperature perturbation performance is investigated. To satisfy the measurement requirements of optical and electric signal processing, a well- designed acquisition circuit board is prepared, and experiments on the performance of the interrogation method are carried out. The experimental results indicate that the optical power resolution of the acquisition circuit border is better than 8 pW, and the stability of the interrogation method with the mechanical adjustment can reach 0.06%. Moreover, the nonlinearity of the interrogation method is 3.3% in the measurable range of 60 pm; the influence of temperature is significantly reduced to 9.5%; the wavelength resolution and response speed can achieve values of 0.3 pm and 500 kHz, respectively. PMID:26184195

  5. Increasing dynamic range of a fibre Bragg grating edge-filtering interrogator with a proportional control loop

    International Nuclear Information System (INIS)

    Stan, Nikola; Bailey, D C; Chadderdon, S L; Selfridge, R H; Schultz, S M; Webb, S; Zikry, M; Peters, K J

    2014-01-01

    We present a fibre Bragg grating (FBG) interrogator that uses a microcontroller board and a tunable optical filter in a proportional control loop to increase dynamic range and achieve high strain sensitivity. It is an edge-filtering interrogator with added proportional control loop that locks the operating wavelength to the mid-reflection point on the FBG spectrum. The interrogator separates low-frequency (LF) components of strain and measures them with extended dynamic range, while at the same time measuring high-frequency (HF) strain without loss in strain sensitivity. In this paper, we describe the implementation of the interrogator and analyse the characteristics of individual components, such as the speed and voltage resolution of the microcontroller and the tunable optical filter. We measure the performance of the proportional control loop at frequencies up to 1 kHz and characterize the system using control theory. We illustrate the limitation of the conventional interrogator to measure strains greater than 40 μϵ and demonstrate successful application of the proposed interrogator for simultaneous measurement of 450 μϵ LF strain at 50 Hz superimposed with 32 kHz HF strain. (paper)

  6. Interrogation in Teacher-Student Interaction in Bahasa Indonesia Learning at Elementary School

    Directory of Open Access Journals (Sweden)

    Akmal Hamsa

    2014-08-01

    Full Text Available Interrogation in Teacher-Student Interaction in Bahasa Indonesia Learning at Elementary School. This study aimed to describe the form, function, and questioning strategies teachers in teacher-student interrogation in Bahasa Indonesia learning in elementary school. Data sourced from four teacher of elementary school, SDN Tamangapa and SD Inpres Tamangapa. Data were obtained by (1 recording, (2 documentation, (3 field notes, (4 interview. The results showed that: (1 the form of questioning the teacher in the teacher-student interaction in Bahasa Indonesia learning in primary schools generally examined the low-level thinking skills, (2 functions of teacher questions are generally intended to check student understanding, and (3 teachers utilize a variety of strategies in addressing student answers correctly and the apparent hesitation. Some disadvantages are indicated teachers in providing interrogation.

  7. Hidden explosives detector employing pulsed neutron and x-ray interrogation

    International Nuclear Information System (INIS)

    Schultz, F.J.; Caldwell, J.T.

    1993-01-01

    Methods and systems for the detection of small amounts of modern, highly-explosive nitrogen-based explosives, such as plastic explosives, hidden in airline baggage. Several techniques are employed either individually or combined in a hybrid system. One technique employed in combination is X-ray imaging. Another technique is interrogation with a pulsed neutron source in a two-phase mode of operation to image both nitrogen and oxygen densities. Another technique employed in combination is neutron interrogation to form a hydrogen density image or three-dimensional map. In addition, deliberately-placed neutron-absorbing materials can be detected

  8. Hidden explosives detector employing pulsed neutron and x-ray interrogation

    Science.gov (United States)

    Schultz, Frederick J.; Caldwell, John T.

    1993-01-01

    Methods and systems for the detection of small amounts of modern, highly-explosive nitrogen-based explosives, such as plastic explosives, hidden in airline baggage. Several techniques are employed either individually or combined in a hybrid system. One technique employed in combination is X-ray imaging. Another technique is interrogation with a pulsed neutron source in a two-phase mode of operation to image both nitrogen and oxygen densities. Another technique employed in combination is neutron interrogation to form a hydrogen density image or three-dimensional map. In addition, deliberately-placed neutron-absorbing materials can be detected.

  9. High-Efficiency Quantum Interrogation Measurements via the Quantum Zeno Effect

    International Nuclear Information System (INIS)

    Kwiat, P. G.; White, A. G.; Mitchell, J. R.; Nairz, O.; Weihs, G.; Weinfurter, H.; Zeilinger, A.

    1999-01-01

    The phenomenon of quantum interrogation allows one to optically detect the presence of an absorbing object, without the measuring light interacting with it. In an application of the quantum Zeno effect, the object inhibits the otherwise coherent evolution of the light, such that the probability that an interrogating photon is absorbed can in principle be arbitrarily small. We have implemented this technique, achieving efficiencies of up to 73% , and consequently exceeding the 50% theoretical maximum of the original ''interaction-free'' measurement proposal. We have also predicted and experimentally verified a previously unsuspected dependence on loss. (c) 1999 The American Physical Society

  10. Interrogative Suggestibility in an Adolescent Forensic Occupation.

    Science.gov (United States)

    Richardson, G.; And Others

    1995-01-01

    Sixty-five juvenile offenders in residential care completed the Gudjonsson Suggestibility Scale, and their scores were matched for IQ and memory with those of 60 adult offenders. The juveniles gave in significantly more to interrogative pressure through negative feedback but were no more yielding to leading questions than adults. (JPS)

  11. Terahertz Science, Technology, and Communication

    Science.gov (United States)

    Chattopadhyay, Goutam

    2013-01-01

    The term "terahertz" has been ubiquitous in the arena of technology over the past couple of years. New applications are emerging every day which are exploiting the promises of terahertz - its small wavelength; capability of penetrating dust, clouds, and fog; and possibility of having large instantaneous bandwidth for high-speed communication channels. Until very recently, space-based instruments for astrophysics, planetary science, and Earth science missions have been the primary motivator for the development of terahertz sensors, sources, and systems. However, in recent years the emerging areas such as imaging from space platforms, surveillance of person-borne hidden weapons or contraband from a safe stand-off distance and reconnaissance, medical imaging and DNA sequencing, and in the world high speed communications have been the driving force for this area of research.

  12. Nondestructive assay of subassemblies of various spent or fresh fuels by active neutron interrogation

    International Nuclear Information System (INIS)

    Ragan, G.L.; Ricker, C.W.; Chiles, M.M.; Ingersoll, D.T.; Slaughter, G.G.

    1979-01-01

    Recent studies show that subassemblies containing various spent fuels could be assayed rapidly and accurately by a nondestructive assay system using active neutron interrogation and prompt-neutron detection. Subassembly penetration is achieved by 24-keV (Sb--Be) interrogation neutrons; the spent-fuel neutron background is overridden by using strong interrogating sources and prompt-neutron signals, and background gammas are absorbed by lead. Experiments have demonstrated the potential for assaying with better than 5% accuracy, three spent plutonium-fueled subassemblies per hour. Calculations, validated by experiments, predict even better performance for fresh or uranium-fueled subassemblies; several performance estimates are given

  13. The relationship between criminal conviction and interrogative suggestibility among delinquent boys.

    Science.gov (United States)

    Gudjonsson, G H; Singh, K K

    1984-03-01

    This study investigates the relationship between interrogative suggestibility, as measured by the Gudjonsson Suggestibility Scale (GSS), and number of previous convictions among 35 delinquent boys. The GSS measures two independent aspects of suggestibility. First, the extent to which subjects give in to suggestive questions. Second, the extent to which subjects give in to interpersonal pressure given in the form of critical feedback about test performance. The number of convictions were found to correlate negatively with the latter aspect of interrogative suggestibility, but not significantly with the former.

  14. Interrogating "Belonging" in Belonging, Being and Becoming: The Early Years Learning Framework for Australia

    Science.gov (United States)

    Sumsion, Jennifer; Wong, Sandie

    2011-01-01

    In this article, the authors interrogate the use of "belonging" in "Belonging, Being and Becoming: the Early Years Learning Framework for Australia" (EYLF), Australia's first national curriculum for early childhood education and care settings and, from the authors' interrogation, possibilities are offered for thinking about and…

  15. Improved Fission Neutron Data Base for Active Interrogation of Actinides

    Energy Technology Data Exchange (ETDEWEB)

    Pozzi, Sara; Czirr, J. Bart; Haight, Robert; Kovash, Michael; Tsvetkov, Pavel

    2013-11-06

    This project will develop an innovative neutron detection system for active interrogation measurements. Many active interrogation methods to detect fissionable material are based on the detection of neutrons from fission induced by fast neutrons or high-energy gamma rays. The energy spectrum of the fission neutrons provides data to identify the fissionable isotopes and materials such as shielding between the fissionable material and the detector. The proposed path for the project is as follows. First, the team will develop new neutron detection systems and algorithms by Monte Carlo simulations and bench-top experiments. Next, They will characterize and calibrate detection systems both with monoenergetic and white neutron sources. Finally, high-fidelity measurements of neutron emission from fissions induced by fast neutrons will be performed. Several existing fission chambers containing U-235, Pu-239, U-238, or Th-232 will be used to measure the neutron-induced fission neutron emission spectra. The challenge for making confident measurements is the detection of neutrons in the energy ranges of 0.01 – 1 MeV and above 8 MeV, regions where the basic data on the neutron energy spectrum emitted from fission is least well known. In addition, improvements in the specificity of neutron detectors are required throughout the complete energy range: they must be able to clearly distinguish neutrons from other radiations, in particular gamma rays and cosmic rays. The team believes that all of these challenges can be addressed successfully with emerging technologies under development by this collaboration. In particular, the collaboration will address the area of fission neutron emission spectra for isotopes of interest in the advanced fuel cycle initiative (AFCI).

  16. Enhanced-locality fiber-optic two-photon-fluorescence live-brain interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Fedotov, I. V.; Doronina-Amitonova, L. V. [International Laser Center, Physics Department, M.V. Lomonosov Moscow State University, Moscow 119992 (Russian Federation); Russian Quantum Center, ul. Novaya 100, Skolkovo, Moscow Region 1430125 (Russian Federation); Kurchatov Institute National Research Center, Moscow (Russian Federation); Sidorov-Biryukov, D. A.; Fedotov, A. B. [International Laser Center, Physics Department, M.V. Lomonosov Moscow State University, Moscow 119992 (Russian Federation); Russian Quantum Center, ul. Novaya 100, Skolkovo, Moscow Region 1430125 (Russian Federation); Anokhin, K. V. [Kurchatov Institute National Research Center, Moscow (Russian Federation); P.K. Anokhin Institute of Normal Physiology, Russian Academy of Medical Sciences, Moscow (Russian Federation); Kilin, S. Ya. [B.I. Stepanov Institute of Physics, National Academy of Sciences of Belarus, Minsk (Belarus); Sakoda, K. [National Institute for Materials Science, 1-1 Namiki, Tsukuba 305-0044 (Japan); Zheltikov, A. M. [International Laser Center, Physics Department, M.V. Lomonosov Moscow State University, Moscow 119992 (Russian Federation); Russian Quantum Center, ul. Novaya 100, Skolkovo, Moscow Region 1430125 (Russian Federation); Department of Physics and Astronomy, Texas A and M University, College Station, Texas 77843 (United States); Center of Photochemistry, Russian Academy of Sciences, ul. Novatorov 7a, Moscow 117421 (Russian Federation)

    2014-02-24

    Two-photon excitation is shown to substantially enhance the locality of fiber-based optical interrogation of strongly scattering biotissues. In our experiments, a high-numerical-aperture, large-core-are fiber probe is used to deliver the 200-fs output of a 100-MHz mode-locked ytterbium fiber laser to samples of live mouse brain, induce two-photon fluorescence of nitrogen–vacancy centers in diamond markers in brain sample. Fiber probes with a high numerical aperture and a large core area are shown to enable locality enhancement in fiber-laser–fiber-probe two-photon brain excitation and interrogation without sacrificing the efficiency of fluorescence response collection.

  17. Integrated Box Interrogation System (IBIS) Preliminary Design Study

    CERN Document Server

    Croft, S; Chard-Mj, P; Estop, J R; Martancik, D; Sheila-Melton; Young, B

    2003-01-01

    Canberra Industries has won the tendered solicitation, INEEL/EST-99-00121 for boxed waste Nondestructive Assay Development and Demonstration. Canberra will provide the Integrated Box Interrogation System (IBIS) which is a suite of assay instrumentation and a data reduction system that addresses the measurement needs for Boxed Wastes identified in the solicitation and facilitates the associated experimental program and demonstration of system capability. The IBIS system will consist of the next generation CWAM system, i.e. CWAM II, which is a Scanning Passive/Active Neutron interrogation system which we will call a Box Segmented Neutron Scanner (BSNS), combined with a physically separate Box Segmented Gamma-ray Scanning (BSGS) system. These systems are based on existing hardware designs but will be tailored to the large sample size and enhanced to allow the program to evaluate the following measurement criteria:Characterization and correction for matrix heterogeneity Characterization of non-uniform radio-nucli...

  18. FBG Interrogation Method with High Resolution and Response Speed Based on a Reflective-Matched FBG Scheme.

    Science.gov (United States)

    Cui, Jiwen; Hu, Yang; Feng, Kunpeng; Li, Junying; Tan, Jiubin

    2015-07-08

    In this paper, a high resolution and response speed interrogation method based on a reflective-matched Fiber Bragg Grating (FBG) scheme is investigated in detail. The nonlinear problem of the reflective-matched FBG sensing interrogation scheme is solved by establishing and optimizing the mathematical model. A mechanical adjustment to optimize the interrogation method by tuning the central wavelength of the reference FBG to improve the stability and anti-temperature perturbation performance is investigated. To satisfy the measurement requirements of optical and electric signal processing, a well- designed acquisition circuit board is prepared, and experiments on the performance of the interrogation method are carried out. The experimental results indicate that the optical power resolution of the acquisition circuit border is better than 8 pW, and the stability of the interrogation method with the mechanical adjustment can reach 0.06%. Moreover, the nonlinearity of the interrogation method is 3.3% in the measurable range of 60 pm; the influence of temperature is significantly reduced to 9.5%; the wavelength resolution and response speed can achieve values of 0.3 pm and 500 kHz, respectively.

  19. Photon interrogation annual report for FY 1979

    International Nuclear Information System (INIS)

    Nieschmidt, E.B.; Johnson, L.O.; Lawrence, R.S.; Vegors, S.H. Jr.

    1980-03-01

    Summaries of experimental information and information from vendors is presented to show the adequacy of the photon interrogation technique for transuranic waste assay. An instrument system is described which has high immunity to gamma flash and has good high count rate capabilities. Comparison of the progress of the program with a schedule presented at its inception is presented

  20. Promotion COPERNIC Energy and Society the interrogations on the world demand evolution; Promotion COPERNIC Energie et Societe les interrogations sur l'evolution de la demande mondiale

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-15

    In the framework of a prospective reflexion emergence on the energy demand, this document presents an analysis of the prospective approach and of recent studies: challenges, interests, limits, validity of the models and hypothesis and results relevance. With this analysis, the authors aim to identify the main interrogations bond to the world energy demand evolution. They then analyse these interrogations in the framework of a sectoral approach (agriculture, industry, transports, residential) in order to detail the demand and to forecast the evolution. Facing the consumption attitudes, they also suggest some new action avenues to favor a sustainable growth. (A.L.B.)

  1. TDM interrogation of intensity-modulated USFBGs network based on multichannel lasers.

    Science.gov (United States)

    Rohollahnejad, Jalal; Xia, Li; Cheng, Rui; Ran, Yanli; Rahubadde, Udaya; Zhou, Jiaao; Zhu, Lin

    2017-01-23

    We report a large-scale multi-channel fiber sensing network, where ultra-short FBGs (USFBGs) instead of conventional narrow-band ultra-weak FBGs are used as the sensors. In the time division multiplexing scheme of the network, each grating response is resolved as three adjacent discrete peaks. The central wavelengths of USFBGs are tracked with the differential detection, which is achieved by calculating the peak-to-peak ratio of two maximum peaks. Compared with previous large-scale hybrid multiplexing sensing networks (e.g., WDM/TDM) which typically have relatively low interrogation speed and very high complexity, the proposed system can achieve interrogation of all channel sensors through very fast and simple intensity measurements with a broad dynamic range. A proof-of-concept experiment with twenty USFBGs, at two wavelength channels, was performed and a fast static strain measurements were demonstrated, with a high average sensitivity of ~0.54dB/µƐ and wide dynamic range of over ~3000µƐ. The channel to channel switching time was 10ms and total network interrogation time was 50ms.

  2. Ion-induced gammas for photofission interrogation of HEU.

    Energy Technology Data Exchange (ETDEWEB)

    Doyle, Barney Lee (Sandia National Laboratories, Albuquerque, NM); Antolak, Arlyn J.; Morse, Daniel H.; Provencio, Paula Polyak (Sandia National Laboratories, Albuquerque, NM)

    2006-03-01

    High-energy photons and neutrons can be used to actively interrogate for heavily shielded special nuclear material (SNM), such as HEU (highly enriched uranium), by detecting prompt and/or delayed induced fission signatures. In this work, we explore the underlying physics for a new type of photon source that generates high fluxes of mono-energetic gamma-rays from low-energy (<500 keV) proton-induced nuclear reactions. The characteristic energies (4- to 18-MeV) of the gamma-rays coincide with the peak of the photonuclear cross section. The source could be designed to produce gamma-rays of certain selected energies, thereby improving the probability of detecting shielded HEU or providing a capability to determine enrichment inside sealed containers. The fundamental physics of such an interrogation source were studied in this LDRD through scaled ion accelerator experiments and radiation transport modeling. The data were used to assess gamma and neutron yields, background, and photofission-induced signal levels from several (p,{gamma}) target materials under consideration.

  3. Processing Interrogative Sentence Mood at the Semantic-Syntactic Interface: An Electrophysiological Research in Chinese, German, and Polish

    Science.gov (United States)

    Kao, Chung-Shan; Dietrich, Rainer; Sommer, Werner

    2010-01-01

    Background Languages differ in the marking of the sentence mood of a polar interrogative (yes/no question). For instance, the interrogative mood is marked at the beginning of the surface structure in Polish, whereas the marker appears at the end in Chinese. In order to generate the corresponding sentence frame, the syntactic specification of the interrogative mood is early in Polish and late in Chinese. In this respect, German belongs to an interesting intermediate class. The yes/no question is expressed by a shift of the finite verb from its final position in the underlying structure into the utterance initial position, a move affecting, hence, both the sentence's final and the sentence's initial constituents. The present study aimed to investigate whether during generation of the semantic structure of a polar interrogative, i.e., the processing preceding the grammatical formulation, the interrogative mood is encoded according to its position in the syntactic structure at distinctive time points in Chinese, German, and Polish. Methodology/Principal Findings In a two-choice go/nogo experimental design, native speakers of the three languages responded to pictures by pressing buttons and producing utterances in their native language while their brain potentials were recorded. The emergence and latency of lateralized readiness potentials (LRP) in nogo conditions, in which speakers asked a yes/no question, should indicate the time point of processing the interrogative mood. The results revealed that Chinese, German, and Polish native speakers did not differ from each other in the electrophysiological indicator. Conclusions/Significance The findings suggest that the semantic encoding of the interrogative mood is temporally consistent across languages despite its disparate syntactic specification. The consistent encoding may be ascribed to economic processing of interrogative moods at various sentential positions of the syntactic structures in languages or, more

  4. Compact, low-cost, and high-resolution interrogation unit for optical sensors

    International Nuclear Information System (INIS)

    Kiesel, Peter; Schmidt, Oliver; Mohta, Setu; Johnson, Noble; Malzer, Stefan

    2006-01-01

    Compact wavelength detectors that resolve wavelength changes in the subpicometer range over a broad spectral range are presented. A photodiode array or position sensor device is coated with a linear variable filter that converts the wavelength of the incident light into a spatial intensity distribution. The centroid of the spatial distribution is determined by a differential readout of the two elements of the photodiode array or the position sensor device. The device can interrogate any optical sensor that produces a wavelength shift in response to a stimulus. The potential of this device was tested by interrogating fiber-Bragg-grating sensors

  5. Design Concept for the Microwave Interrogation Structure in PARCS

    National Research Council Canada - National Science Library

    Dick, G. J; Klipstein, W. M; Heavner, T. P; Jefferts, S. R

    2002-01-01

    In this paper we will describe key aspects of the conceptual design of the microwave interrogation structure in the laser-cooled cesium frequency standard that is part of the Primary Atomic Reference Clock in Space (PARCS) experiment...

  6. Correcting the effects of the matrix using capture gamma-ray spectrometry: Application to measurement by Active Neutron Interrogation; Correction des effets de matrice par spectrometrie des rayonnements gamma de capture: Application a la mesure par Interrogation Neutronique Active (I.N.A.)

    Energy Technology Data Exchange (ETDEWEB)

    Baudry, G.

    2003-11-15

    In the field of the measurement of low masses of fissile material ({sup 235}U, {sup 239}Pu, {sup 241}Pu) in radioactive waste drums, the Active Neutron Interrogation is a non-destructive method achieving good results. It does however remain reliant upon uncertainties related to the matrix effects on interrogation and fission neutrons. The aim of this thesis is to develop a correction method able to take into account these matrix effects by quantifying the amount of absorbent materials (chlorine and hydrogen) in a 118- liter homogeneous matrix. The main idea is to use the gamma-ray spectrometry of gamma emitted by neutron captures to identify and quantify the composition of the matrix. An indicator from its chlorine content is then deduced in order to choose the calibration coefficient which best represents the real composition of the matrix. This document firstly presents the needs of control and characterization of radioactive objects, and the means used in the field of nuclear measurement. Emphases is put in particular on the Active Neutron Interrogation method. The matrices of interest are those made of light technological waste (density {<=} 0,4 g/cm{sup 3}) containing hydrogenated and chlorinated materials. The advantages of gamma-rays emitted by neutron captures for the determination of a chlorine content indicator of the matrices and the principles of the correction method are then explained. Measurements have been firstly realized with an existing Neutron Interrogation device (PROMETHEE 6). Such measurements have proven its inadequacy: no signal from the matrix hydrogen was detected, due to an intense signal from the polyethylene contained in some cell elements. Moreover, the matrix chlorine content appeared difficult to be measured. A new and specific device, named REGAIN and dedicated to active gamma-rays spectrometry, was defined with the Monte-Carlo N-Particle (MCNP) code. The experiments conducted with this new device made it possible to detect the

  7. Monte Carlo Simulation for LINAC Standoff Interrogation of Nuclear Material

    International Nuclear Information System (INIS)

    Clarke, Shaun D.; Flaska, Marek; Miller, Thomas Martin; Protopopescu, Vladimir A.; Pozzi, Sara A.

    2007-01-01

    The development of new techniques for the interrogation of shielded nuclear materials relies on the use of Monte Carlo codes to accurately simulate the entire system, including the interrogation source, the fissile target and the detection environment. The objective of this modeling effort is to develop analysis tools and methods-based on a relevant scenario-which may be applied to the design of future systems for active interrogation at a standoff. For the specific scenario considered here, the analysis will focus on providing the information needed to determine the type and optimum position of the detectors. This report describes the results of simulations for a detection system employing gamma rays to interrogate fissile and nonfissile targets. The simulations were performed using specialized versions of the codes MCNPX and MCNP-PoliMi. Both prompt neutron and gamma ray and delayed neutron fluxes have been mapped in three dimensions. The time dependence of the prompt neutrons in the system has also been characterized For this particular scenario, the flux maps generated with the Monte Carlo model indicate that the detectors should be placed approximately 50 cm behind the exit of the accelerator, 40 cm away from the vehicle, and 150 cm above the ground. This position minimizes the number of neutrons coming from the accelerator structure and also receives the maximum flux of prompt neutrons coming from the source. The lead shielding around the accelerator minimizes the gamma-ray background from the accelerator in this area. The number of delayed neutrons emitted from the target is approximately seven orders of magnitude less than the prompt neutrons emitted from the system. Therefore, in order to possibly detect the delayed neutrons, the detectors should be active only after all prompt neutrons have scattered out of the system. Preliminary results have shown this time to be greater than 5 ?s after the accelerator pulse. This type of system is illustrative of a

  8. Promotion COPERNIC Energy and Society the interrogations on the world demand evolution; Promotion COPERNIC Energie et Societe les interrogations sur l'evolution de la demande mondiale

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-15

    In the framework of a prospective reflexion emergence on the energy demand, this document presents an analysis of the prospective approach and of recent studies: challenges, interests, limits, validity of the models and hypothesis and results relevance. With this analysis, the authors aim to identify the main interrogations bond to the world energy demand evolution. They then analyse these interrogations in the framework of a sectoral approach (agriculture, industry, transports, residential) in order to detail the demand and to forecast the evolution. Facing the consumption attitudes, they also suggest some new action avenues to favor a sustainable growth. (A.L.B.)

  9. AWG Filter for Wavelength Interrogator

    Science.gov (United States)

    Black, Richard J. (Inventor); Costa, Joannes M. (Inventor); Faridian, Fereydoun (Inventor); Moslehi, Behzad (Inventor); Sotoudeh, Vahid (Inventor)

    2015-01-01

    A wavelength interrogator is coupled to a circulator which couples optical energy from a broadband source to an optical fiber having a plurality of sensors, each sensor reflecting optical energy at a unique wavelength and directing the reflected optical energy to an AWG. The AWG has a detector coupled to each output, and the reflected optical energy from each grating is coupled to the skirt edge response of the AWG such that the adjacent channel responses form a complementary pair response. The complementary pair response is used to convert an AWG skirt response to a wavelength.

  10. Interrogating Public Sphere and Popular Culture as Theoretical ...

    African Journals Online (AJOL)

    Because of its theoretical roots in Western liberal thinking, scholars in African studies such as Comaroffs, Mamdani and Ekeh have vigorously debated the extent to which the concept of civil society is useful in explaining and interrogating developments in Africa. However, the concept of the public sphere has been subjected ...

  11. Characterization of a FBG sensor interrogation system based on a mode-locked laser scheme.

    Science.gov (United States)

    Madrigal, Javier; Fraile-Peláez, Francisco Javier; Zheng, Di; Barrera, David; Sales, Salvador

    2017-10-02

    This paper is focused on the characterization of a fiber Bragg grating (FBG) sensor interrogation system based on a fiber ring laser with a semiconductor optical amplifier as the gain medium, and an in-loop electro-optical modulator. This system operates as a switchable active (pulsed) mode-locked laser. The operation principle of the system is explained theoretically and validated experimentally. The ability of the system to interrogate an array of different FBGs in wavelength and spatial domain is demonstrated. Simultaneously, the influence of several important parameters on the performance of the interrogation technique has been investigated. Specifically, the effects of the bandwidth and the reflectivity of the FBGs, the SOA gain, and the depth of the intensity modulation have been addressed.

  12. Correcting the effects of the matrix using capture gamma-ray spectrometry: Application to measurement by Active Neutron Interrogation

    International Nuclear Information System (INIS)

    Baudry, G.

    2003-11-01

    In the field of the measurement of low masses of fissile material ( 235 U, 239 Pu, 241 Pu) in radioactive waste drums, the Active Neutron Interrogation is a non-destructive method achieving good results. It does however remain reliant upon uncertainties related to the matrix effects on interrogation and fission neutrons. The aim of this thesis is to develop a correction method able to take into account these matrix effects by quantifying the amount of absorbent materials (chlorine and hydrogen) in a 118- liter homogeneous matrix. The main idea is to use the gamma-ray spectrometry of gamma emitted by neutron captures to identify and quantify the composition of the matrix. An indicator from its chlorine content is then deduced in order to choose the calibration coefficient which best represents the real composition of the matrix. This document firstly presents the needs of control and characterization of radioactive objects, and the means used in the field of nuclear measurement. Emphases is put in particular on the Active Neutron Interrogation method. The matrices of interest are those made of light technological waste (density ≤ 0,4 g/cm 3 ) containing hydrogenated and chlorinated materials. The advantages of gamma-rays emitted by neutron captures for the determination of a chlorine content indicator of the matrices and the principles of the correction method are then explained. Measurements have been firstly realized with an existing Neutron Interrogation device (PROMETHEE 6). Such measurements have proven its inadequacy: no signal from the matrix hydrogen was detected, due to an intense signal from the polyethylene contained in some cell elements. Moreover, the matrix chlorine content appeared difficult to be measured. A new and specific device, named REGAIN and dedicated to active gamma-rays spectrometry, was defined with the Monte-Carlo N-Particle (MCNP) code. The experiments conducted with this new device made it possible to detect the hydrogen from the

  13. Development of a Liquid Scintillator-Based Active Interrogation System for LEU Fuel Assemblies

    International Nuclear Information System (INIS)

    Lavietes, Anthony D.; Plenteda, Romano; Mascahrenas, Nicholas; Cronholm, L. Marie; Aspinall, Michael; Joyce, Malcolm; Tomanin, Alice; Peerani, Paolo

    2013-06-01

    The IAEA, in collaboration with the Joint Research Center (Ispra, IT) and Hybrid Instruments (Lancaster, UK), has developed a full scale, liquid scintillator-based active interrogation system to determine uranium (U) mass in fresh fuel assemblies. The system implements an array of moderate volume (∼1000 ml) liquid scintillator detectors, a multichannel pulse shape discrimination (PSD) system, and a high-speed data acquisition and signal processing system to assess the U content of fresh fuel assemblies. Extensive MCNPX-PoliMi modelling has been carried out to refine the system design and optimize the detector performance. These measurements, traditionally performed with 3 He-based assay systems (e.g., Uranium Neutron Coincidence Collar [UNCL], Active Well Coincidence Collar [AWCC]), can now be performed with higher precision in a fraction of the acquisition time. The system uses a high-flash point, non-hazardous scintillating fluid (EJ309) enabling their use in commercial nuclear facilities and achieves significantly enhanced performance and capabilities through the combination of extremely short gate times, adjustable energy detection threshold, real-time PSD electronics, and high-speed, FPGA-based data acquisition. Given the possible applications, this technology is also an excellent candidate for the replacement of select 3 He-based systems. Comparisons to existing 3 He-based active interrogation systems are presented where possible to provide a baseline performance reference. This paper will describe the laboratory experiments and associated modelling activities undertaken to develop and initially test the prototype detection system. (authors)

  14. Wirelessly Interrogated Wear or Temperature Sensors

    Science.gov (United States)

    Woodard, Stanley E.; Taylor, Bryant D.

    2010-01-01

    Sensors for monitoring surface wear and/or temperature without need for wire connections have been developed. Excitation and interrogation of these sensors are accomplished by means of a magnetic-field-response recorder. In a sensor of the present type as in the previously reported ones, the capacitance and, thus, the resonance frequency, varies as a known function of the quantity of interest that one seeks to determine. Hence, the resonance frequency is measured and used to calculate the quantity of interest.

  15. A national epidemiological study investigating risk factors for police interrogation and false confession among juveniles and young persons.

    Science.gov (United States)

    Gudjonsson, Gisli H; Sigurdsson, Jon Fridrik; Sigfusdottir, Inga Dora; Asgeirsdottir, Bryndis Bjork; González, Rafael A; Young, Susan

    2016-03-01

    The principal aims of this study are to identify risk factors associated with police arrest and false confessions and to investigate whether the severity of the ADHD condition/symptoms increases the risk. 22,226 young persons in Iceland anonymously completed self-report questionnaires screening for conduct disorder and ADHD. In addition, they stated whether they had a diagnosis of ADHD and had received ADHD medication, and their history of offending, police interrogation and false confession. Participants were stratified into two age groups, 14-16 and 17-24 years. The older group was significantly more likely to have been interrogated by the police but the younger group were much more vulnerable to false confession during interrogation. Males were more likely to be at risk for both than females. The severity of the ADHD condition increased the risk of both interrogation and false confession. Negative binomial regressions showed that age, gender, conduct disorder, offending, and ADHD symptoms were all significant predictors of both interrogations and number of false confessions. Conduct disorder was the single best predictor of police interrogation, but the findings were more mixed regarding false confessions. Young people presenting with a combination of severe ADHD and comorbid conduct disorder had the worst outcome for both interrogation and false confessions. The findings endorse the need for support of persons with ADHD to be put in place to ensure fair due process and to prevent miscarriages of justice.

  16. Interrogating Infanticide/ Child Euthanasia in the Roman Christian ...

    African Journals Online (AJOL)

    The purpose of this paper is an attempt to examine infanticide practices in the Roman Christian era and interrogate infanticide and child euthanasia in the same era. It also attempts to point out infanticide practices in Abuja and makes a distinction between infanticide and child euthanasia in Abuja. The study employed ...

  17. On the aesthetics of mimicry and proliferation: interrogations of ...

    African Journals Online (AJOL)

    This article examines innovative modes of interrogating spectacles of State power in postcolonial dictatorship novels. Authoritarian power in the postcolonial public sphere perpetuates itself through practices that reiterate the prerogatives of State reason, national progress, national unity and the indispensability of the ...

  18. System design considerations for fast-neutron interrogation systems

    International Nuclear Information System (INIS)

    Micklich, B.J.; Curry, B.P.; Fink, C.L.; Smith, D.L.; Yule, T.J.

    1993-01-01

    Nonintrusive interrogation techniques that employ fast neutrons are of interest because of their sensitivity to light elements such as carbon, nitrogen, and oxygen. The primary requirement of a fast-neutron inspection system is to determine the value of atomic densities, or their ratios, over a volumetric grid superimposed on the object being interrogated. There are a wide variety of fast-neutron techniques that can provide this information. The differences between the various nuclear systems can be considered in light of the trade-offs relative to the performance requirements for each system's components. Given a set of performance criteria, the operational requirements of the proposed nuclear systems may also differ. For instance, resolution standards will drive scanning times and tomographic requirements, both of which vary for the different approaches. We are modelling a number of the fast-neutron interrogation techniques currently under consideration, to include Fast Neutron Transmission Spectroscopy (FNTS), Pulsed Fast Neutron Analysis (PFNA), and its variant, 14-MeV Associated Particle Imaging (API). The goals of this effort are to determine the component requirements for each technique, identify trade-offs that system performance standards impose upon those component requirements, and assess the relative advantages and disadvantages of the different approaches. In determining the component requirements, we will consider how they are driven by system performance standards, such as image resolution, scanning time, and statistical uncertainty. In considering the trade-offs between system components, we concentrate primarily on those which are common to all approaches, for example: source characteristics versus detector array requirements. We will then use the analysis to propose some figures-of-merit that enable performance comparisons between the various fast-neutron systems under consideration. The status of this ongoing effort is presented

  19. Assessment of effectiveness of geologic isolation systems: the feasibility of computer interrogation of experts for WISAP

    Energy Technology Data Exchange (ETDEWEB)

    Wight, L.H.

    1980-05-01

    Simulation of the response of a waste repository to events that could initiate a fault tree to breach and failure is currently a keystone to the Battelle Waste Isolation Safety Assessment Program (WISAP). The repository simulation, which is part of the Disruptive Event Analysis Task, models the repository for its entire design life, one million years. This is clearly a challenging calculation, requiring input unlike any other response analysis by virtue of the long design life of the facility. What technology will provide design criteria for a million year design life. Answers to questions like this can, to some extent, be based on data, but always require some subjective judgments. The subjectivity, which is sometimes driven by inadequate or incomplete data or by a lack of understanding of the physical process, is therefore a crucial ingredient in an analysis of initiating events. Because of the variety of possible initiating events (glaciation, man-caused disruption, volcanism, etc.), many expert opinions will be solicited as input. The complexity of the simulation, the variety of experts involved, and the volume of applicable data all suggest that there may be a more direct, economical method to solicit the expert opinion. This report addresses the feasibility of such a system. Background information is presented that demonstrates the advantages of a computer interrogation system over conventional interrogation and assessment techniques. In the subsequent three sections the three elements - structure and decomposition, scaling, and synthesis - that are basic to any interrogation and assessment technique are reviewed. The interrelationship are schematically illustrated between these three fundamental elements and, therefore, serves as a useful guide to these three sections. Each of these three sections begins with a recommended approach to the particular element and ends with an illustration of representative dialogue.

  20. Assessment of effectiveness of geologic isolation systems: the feasibility of computer interrogation of experts for WISAP

    International Nuclear Information System (INIS)

    Wight, L.H.

    1980-05-01

    Simulation of the response of a waste repository to events that could initiate a fault tree to breach and failure is currently a keystone to the Battelle Waste Isolation Safety Assessment Program (WISAP). The repository simulation, which is part of the Disruptive Event Analysis Task, models the repository for its entire design life, one million years. This is clearly a challenging calculation, requiring input unlike any other response analysis by virtue of the long design life of the facility. What technology will provide design criteria for a million year design life. Answers to questions like this can, to some extent, be based on data, but always require some subjective judgments. The subjectivity, which is sometimes driven by inadequate or incomplete data or by a lack of understanding of the physical process, is therefore a crucial ingredient in an analysis of initiating events. Because of the variety of possible initiating events (glaciation, man-caused disruption, volcanism, etc.), many expert opinions will be solicited as input. The complexity of the simulation, the variety of experts involved, and the volume of applicable data all suggest that there may be a more direct, economical method to solicit the expert opinion. This report addresses the feasibility of such a system. Background information is presented that demonstrates the advantages of a computer interrogation system over conventional interrogation and assessment techniques. In the subsequent three sections the three elements - structure and decomposition, scaling, and synthesis - that are basic to any interrogation and assessment technique are reviewed. The interrelationship are schematically illustrated between these three fundamental elements and, therefore, serves as a useful guide to these three sections. Each of these three sections begins with a recommended approach to the particular element and ends with an illustration of representative dialogue

  1. Calibration of Cherenkov detectors for monoenergetic photon imaging in active interrogation applications

    Energy Technology Data Exchange (ETDEWEB)

    Rose, P.B., E-mail: prose6@gatech.edu; Erickson, A.S., E-mail: anna.erickson@me.gatech.edu

    2015-11-01

    Active interrogation of cargo containers using monoenergetic photons offers a rapid and low-dose approach to search for shielded special nuclear materials. Cherenkov detectors can be used for imaging of the cargo provided that gamma ray energies used in interrogation are well resolved, as the case in {sup 11}B(d,n-γ){sup 12}C reaction resulting in 4.4 MeV and 15.1 MeV photons. While an array of Cherenkov threshold detectors reduces low energy background from scatter while providing the ability of high contrast transmission imaging, thus confirming the presence of high-Z materials, these detectors require a special approach to energy calibration due to the lack of resolution. In this paper, we discuss the utility of Cherenkov detectors for active interrogation with monoenergetic photons as well as the results of computational and experimental studies of their energy calibration. The results of the studies with sources emitting monoenergetic photons as well as complex gamma ray spectrum sources, for example {sup 232}Th, show that calibration is possible as long as the energies of photons of interest are distinct.

  2. Active interrogation using energetic protons

    International Nuclear Information System (INIS)

    Morris, Christopher L.; Chung, Kiwhan; Greene, Steven J.; Hogan, Gary E.; Makela, Mark; Mariam, Fesseha; Milner, Edward C.; Murray, Matthew; Saunders, Alexander; Spaulding, Randy; Wang, Zhehui; Waters, Laurie; Wysocki, Frederick

    2010-01-01

    Energetic proton beams provide an attractive alternative when compared to electromagnetic and neutron beams for active interrogation of nuclear threats because they have large fission cross sections, long mean free paths and high penetration, and they can be manipulated with magnetic optics. We have measured time-dependent cross sections and neutron yields for delayed neutrons and gamma rays using 800 MeV and 4 GeV proton beams with a set of bare and shielded targets. The results show significant signals from both unshielded and shielded nuclear materials. Measurements of neutron energies yield suggest a signature unique to fissile material. Results are presented in this paper.

  3. Functional interrogation of non-coding DNA through CRISPR genome editing.

    Science.gov (United States)

    Canver, Matthew C; Bauer, Daniel E; Orkin, Stuart H

    2017-05-15

    Methodologies to interrogate non-coding regions have lagged behind coding regions despite comprising the vast majority of the genome. However, the rapid evolution of clustered regularly interspaced short palindromic repeats (CRISPR)-based genome editing has provided a multitude of novel techniques for laboratory investigation including significant contributions to the toolbox for studying non-coding DNA. CRISPR-mediated loss-of-function strategies rely on direct disruption of the underlying sequence or repression of transcription without modifying the targeted DNA sequence. CRISPR-mediated gain-of-function approaches similarly benefit from methods to alter the targeted sequence through integration of customized sequence into the genome as well as methods to activate transcription. Here we review CRISPR-based loss- and gain-of-function techniques for the interrogation of non-coding DNA. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Dual Neutral Particle Beam Interrogation of Intermodal Shipping Containers for Special Nuclear Material

    Science.gov (United States)

    Keith, Rodney Lyman

    Intermodal shipping containers entering the United States provide an avenue to smuggle unsecured or stolen special nuclear material (SNM). The only direct method fielded to indicate the presence of SNM is by passive photon/neutron radiation detection. Active interrogation using neutral particle beams to induce fission in SNM is a method under consideration. One by-product of fission is the creation of fragments that undergo radioactive decay over a time period on the order of tens of seconds after the initial event. The "delayed" gamma-rays emitted from these fragments over this period are considered a hallmark for the presence of SNM. A fundamental model is developed using homogenized cargos with a SNM target embedded at the center and computationally interrogated using simultaneous neutron and photon beams. Findings from analysis of the delayed gamma emissions from these experiments are intended to mitigate the effects of poor quality information about the composition and disposition of suspect cargo before examination in an active interrogation portal.

  5. [Research on symmetrical optical waveguide based surface plasmon resonance sensing with spectral interrogation].

    Science.gov (United States)

    Zhang, Yi-long; Liu, Le; Guo, Jun; Zhang, Peng-fei; Guo, Ji-hua; Ma, Hui; He, Yong-hong

    2015-02-01

    Surface plasmon resonance (SPR) sensors with spectral interrogation can adopt fiber to transmit light signals, thus leaving the sensing part separated, which is very convenient for miniaturization, remote-sensing and on-site analysis. Symmetrical optical waveguide (SOW) SPR has the same refractive index of the-two buffer media layers adjacent to the metal film, resulting in longer propagation distance, deeper penetration depth and better performance compared to conventional SPR In the present paper, we developed a symmetrical optical, waveguide (SOW) SPR sensor with wavelength interrogation. In the system, MgF2-Au-MgF2 film was used as SOW module for glucose sensing, and a fiber based light source and detection was used in the spectral interrogation. In the experiment, a refractive index resolution of 2.8 x 10(-7) RIU in fluid protocol was acquired. This technique provides advantages of high resolution and could have potential use in compact design, on-site analysis and remote sensing.

  6. Remotely Interrogated Passive Polarizing Dosimeter (RIPPeD).

    Energy Technology Data Exchange (ETDEWEB)

    Kemme, Shanalyn A.; Buller, Daniel L.; Dirk, Shawn M.; Boye, Robert R.; Samora, Sally; Washburn, Cody M.; Wheeler, David Roger

    2008-09-01

    Conductive polymers have become an extremely useful class of materials for many optical applications. We have developed an electrochemical growth method for depositing highly conductive ({approx}100 S/cm) polypyrrole. Additionally, we have adapted advanced fabrication methods for use with the polypyrrole resulting in gratings with submicron features. This conductive polymer micro-wire grid provides an optical polarizer with unique properties. When the polymer is exposed to ionizing radiation, its conductivity is affected and the polarization properties of the device, specifically the extinction ratio, change in a corresponding manner. This change in polarization properties can be determined by optically interrogating the device, possibly from a remote location. The result is a passive radiation-sensitive sensor with very low optical visibility. The ability to interrogate the device from a safe standoff distance provides a device useful in potentially dangerous environments. Also, the passive nature of the device make it applicable in applications where external power is not available. We will review the polymer deposition, fabrication methods and device design and modeling. The characterization of the polymer's sensitivity to ionizing radiation and optical testing of infrared polarizers before and after irradiation will also be presented. These experimental results will highlight the usefulness of the conductive infrared polarizer to many security and monitoring applications.

  7. Remotely Interrogated Passive Polarizing Dosimeter (RIPPeD)

    International Nuclear Information System (INIS)

    Kemme, Shanalyn A.; Buller, Daniel L.; Dirk, Shawn M.; Boye, Robert R.; Samora, Sally; Washburn, Cody M.; Wheeler, David Roger

    2008-01-01

    Conductive polymers have become an extremely useful class of materials for many optical applications. We have developed an electrochemical growth method for depositing highly conductive (∼100 S/cm) polypyrrole. Additionally, we have adapted advanced fabrication methods for use with the polypyrrole resulting in gratings with submicron features. This conductive polymer micro-wire grid provides an optical polarizer with unique properties. When the polymer is exposed to ionizing radiation, its conductivity is affected and the polarization properties of the device, specifically the extinction ratio, change in a corresponding manner. This change in polarization properties can be determined by optically interrogating the device, possibly from a remote location. The result is a passive radiation-sensitive sensor with very low optical visibility. The ability to interrogate the device from a safe standoff distance provides a device useful in potentially dangerous environments. Also, the passive nature of the device make it applicable in applications where external power is not available. We will review the polymer deposition, fabrication methods and device design and modeling. The characterization of the polymer's sensitivity to ionizing radiation and optical testing of infrared polarizers before and after irradiation will also be presented. These experimental results will highlight the usefulness of the conductive infrared polarizer to many security and monitoring applications

  8. Promotion COPERNIC Energy and Society the interrogations on the world demand evolution

    International Nuclear Information System (INIS)

    2001-12-01

    In the framework of a prospective reflexion emergence on the energy demand, this document presents an analysis of the prospective approach and of recent studies: challenges, interests, limits, validity of the models and hypothesis and results relevance. With this analysis, the authors aim to identify the main interrogations bond to the world energy demand evolution. They then analyse these interrogations in the framework of a sectoral approach (agriculture, industry, transports, residential) in order to detail the demand and to forecast the evolution. Facing the consumption attitudes, they also suggest some new action avenues to favor a sustainable growth. (A.L.B.)

  9. Ortho-Babinet polarization-interrogating filter: an interferometric approach to polarization measurement.

    Science.gov (United States)

    Van Delden, Jay S

    2003-07-15

    A novel, interferometric, polarization-interrogating filter assembly and method for the simultaneous measurement of all four Stokes parameters across a partially polarized irradiance image in a no-moving-parts, instantaneous, highly sensitive manner is described. In the reported embodiment of the filter, two spatially varying linear retarders and a linear polarizer comprise an ortho-Babinet, polarization-interrogating (OBPI) filter. The OBPI filter uniquely encodes the incident ensemble of electromagnetic wave fronts comprising a partially polarized irradiance image in a controlled, deterministic, spatially varying manner to map the complete state of polarization across the image to local variations in a superposed interference pattern. Experimental interferograms are reported along with a numerical simulation of the method.

  10. Interrogating Your Wisdom of Practice to Improve Classroom Practices

    Science.gov (United States)

    Chappell, Philip

    2017-01-01

    This article presents a heuristic for language teachers to articulate and explore their fundamental theories of and philosophical stances towards language, language learning, and language teaching. It includes tools with which teachers can interrogate those theories, weighing them up against their actual classroom practices. Through presenting…

  11. Optical power-based interrogation of plasmonic tilted fiber Bragg grating biosensors

    Science.gov (United States)

    González-Vila, Á.; Lopez-Aldaba, A.; Kinet, D.; Mégret, P.; Lopez-Amo, M.; Caucheteur, C.

    2017-04-01

    Two interrogation techniques for plasmonic tilted fiber Bragg grating sensors are reported and experimentally tested. Typical interrogation methods are usually based on tracking the wavelength shift of the most sensitive cladding mode, but for biosensing applications, spectrometer-based methods can be replaced by more efficient solutions. The proposed techniques thus rely on the measurement of the induced changes in optical power. The first one consists of a properly polarized tunable laser source set to emit at the wavelength of the sensor most sensitive mode and an optical power meter to measure the transmitted response. For the second method, a uniform fiber Bragg grating is photo-inscribed beyond the sensor in such a way that its central wavelength matches the sensor most sensitive mode, acting as an optical filter. Using a LED source, light reflected backwards by this grating is partially attenuated when passing through the sensor due to plasmon wave excitation and the power changes are quantified once again with an optical power meter. A performance analysis of the techniques is carried out and they both result competitive interrogation solutions. The work thus focuses on the development of cost-effective alternatives for monitoring this kind of biosensors in practical situations.

  12. Investigation of Active Interrogation Techniques to Detect Special Nuclear Material in Maritime Environments

    International Nuclear Information System (INIS)

    Miller, Thomas Martin; Patton, Bruce W.

    2010-01-01

    The detection and interdiction of special nuclear material (SNM) is still a high-priority focus area for many organizations around the world. One method that is commonly considered a leading candidate in the detection of SNM is active interrogation (AI). AI is different from its close relative, passive interrogation, in that an active source is used to enhance or create a detectable signal (usually fission) from SNM, particularly in shielded scenarios or scenarios where the SNM has a low activity. The use of AI thus makes the detection of SNM easier or, in some scenarios, even enables previously impossible detection. In this work the signal from prompt neutrons and photons as well as delayed neutrons and photons will be combined, as is typically done in AI. In previous work AI has been evaluated experimentally and computationally. However, for the purposes of this work, past scenarios are considered lightly shielded and tightly coupled spatially. At most, the previous work interrogated the contents of one standard cargo container (2.44 x 2.60 x 6.10 m) and the source and detector were both within a few meters of the object being interrogated. A few examples of this type of previous work can be found in references 1 and 2. Obviously, more heavily shielded AI scenarios will require larger source intensities, larger detector surface areas (larger detectors or more detectors), greater detector efficiencies, longer count times, or some combination of these.

  13. On Functional Potential of Interrogative Structures in Academic Linguistic Discourse

    Directory of Open Access Journals (Sweden)

    Sergey Trofimovich Nefedov

    2015-11-01

    Full Text Available The paper deals with the language of scientific communication in the field of linguistics, namely, with the functional potential of the interrogative structures in the form of direct and embedded questions. From a pragmatic perspective the interrogative structures does not seem to be compatible with the contexts of scientific interaction: scientists do not ask for information, but they offer their own solutions for the problem situations. This is reflected in the extremely low frequency of questions in academic research articles and monographs. Their text frequency works out a little over 2 % of the total number of the text predications and that of direct questions is about 1 %. Therefore, their place in verbalization of scientific knowledge in linguistics is metaphorically characterized in this article as «interrogative prohibition» by analogy with the «prohibitions» of Harald Weinrich who introduced several notions point to rarely used linguistic units: «prohibition of authorization» – das «Ich-Verbot», «narrative prohibition» – das «Erzähl-Verbot»; «prohibition of metaphors»– das «MetaphernVerbot». In its turn, low frequency makes the analyzed structures an effective tool to formulate the discussed problems, enables further argumentation, integrate the current text into overall linguistic discourse, control the development of the argumentation in scientific text and finally to draw the recipient's attention to a crucial or unexpected argument.

  14. Metabolic interrogation as a tool to optimize chemotherapeutic regimens.

    Science.gov (United States)

    Sandulache, Vlad C; Chen, Yunyun; Feng, Lei; William, William N; Skinner, Heath D; Myers, Jeffrey N; Meyn, Raymond E; Li, Jinzhong; Mijiti, Ainiwaer; Bankson, James A; Fuller, Clifton D; Konopleva, Marina Y; Lai, Stephen Y

    2017-03-14

    Platinum-based (Pt) chemotherapy is broadly utilized in the treatment of cancer. Development of more effective, personalized treatment strategies require identification of novel biomarkers of treatment response. Since Pt compounds are inactivated through cellular metabolic activity, we hypothesized that metabolic interrogation can predict the effectiveness of Pt chemotherapy in a pre-clinical model of head and neck squamous cell carcinoma (HNSCC).We tested the effects of cisplatin (CDDP) and carboplatin (CBP) on DNA damage, activation of cellular death cascades and tumor cell metabolism, specifically lactate production. Pt compounds induced an acute dose-dependent, transient drop in lactate generation in vitro, which correlated with effects on DNA damage and cell death. Neutralization of free radical stress abrogated these effects. The magnitude of this effect on lactate production correlated with the differential sensitivity of HNSCC cells to Pt compounds (CDDP vs CBP) and p53-driven Pt chemotherapy resistance. Using dual flank xenograft tumors, we demonstrated that Pt-driven effects on lactate levels correlate with effects on tumor growth delay in a dose-dependent manner and that lactate levels can define the temporal profile of Pt chemotherapy-induced metabolic stress. Lactate interrogation also predicted doxorubicin effects on cell death in both solid tumor (HNSCC) and acute myelogenous leukemia (AML) cell lines.Real-time metabolic interrogation of acute changes in cell and tumor lactate levels reflects chemotherapy effects on DNA damage, cell death and tumor growth delay. We have identified a real-time biomarker of chemotherapy effectiveness which can be used to develop adaptive, iterative and personalized treatment regimens against a variety of solid and hematopoietic malignancies.

  15. Characterization of FBG sensor interrogation based on a FDML wavelength swept laser

    Science.gov (United States)

    Jung, Eun Joo; Kim, Chang-Seok; Jeong, Myung Yung; Kim, Moon Ki; Jeon, Min Yong; Jung, Woonggyu; Chen, Zhongping

    2012-01-01

    In this study, we develop an ultra-fast fiber Bragg grating sensor system that is based on the Fourier domain mode-locked (FDML) swept laser. A FDML wavelength swept laser has many advantages compared to the conventional wavelength swept laser source, such as high-speed interrogation, narrow spectral sensitivity, and high phase stability. The newly developed FDML wavelength swept laser shows a superior performance of a high scan rate of 31.3 kHz and a broad scan range of over 70 nm simultaneously. The performance of the grating sensor interrogating system using a FDML wavelength swept laser is characterized in both static and dynamic strain responses. PMID:18852764

  16. Interrogation of weak Bragg grating sensors based on dual-wavelength differential detection.

    Science.gov (United States)

    Cheng, Rui; Xia, Li

    2016-11-15

    It is shown that for weak Bragg gratings the logarithmic ratio of reflected intensities at any two wavelengths within the spectrum follows a linear relationship with the Bragg wavelength shift, with a slope proportional to their wavelength spacing. This finding is exploited to develop a flexible, efficient, and cheap interrogation solution of weak fiber Bragg grating (FBGs), especially ultra-short FBGs, in distributed sensing based on dual-wavelength differential detection. The concept is experimentally studied in both single and distributed sensing systems with ultra-short FBG sensors. The work may form the basis of new and promising FBG interrogation techniques based on detecting discrete rather than continuous spectra.

  17. On the actual bandwidth of some dynamic fiber optic strain/temperature interrogators

    Science.gov (United States)

    Preizler, Rotem R.; Davidi, R.; Motil, Avi; Botsev, Yakov; Hahami, Meir; Tur, Moshe

    2017-04-01

    The measurement accuracy of dynamic fiber-optic sensing interrogators, which use frequency scanning to determine the value of the measured, err as either the event bandwidth approaches half the instrument sampling frequency or when the event dynamic range comes close to the instrument designed value. One main source of error is the common practice of assigning sampling at a non-uniform grid to a uniform one. Harmonics higher than -20 dB are observed for signal frequencies exceeding 25% of the sampling rate and/or for signal amplitudes higher than 15% of the instrument dynamic range. These findings have applications to fiber-Bragg-grating and Brillouin interrogators.

  18. Radio-frequency unbalanced M-Z interferometer for wavelength interrogation of fiber Bragg grating sensors.

    Science.gov (United States)

    Zhou, Jiaao; Xia, Li; Cheng, Rui; Wen, Yongqiang; Rohollahnejad, Jalal

    2016-01-15

    The optical unbalanced Mach-Zehnder interferometer (UMZI) has attracted significant interests for interrogation of FBG sensors owing to its excellent advantages in sensitivity, resolution, and demodulation speed. But this method is still limited to dynamic measurements due to its poor stability and reliability when used for quasi-static detections. Here, we propose for the first time, to the best of our knowledge, a radio-frequency unbalanced M-Z interferometer (RF-UMZI) for interrogation of FBG sensors, which, owing to its operation in an incoherent rather than a coherent regime, provides an ideal solution for the existing stability problem of the conventional UMZI, with remarkable features of adjustable resolution and potentially extremely high sensitivity. A dispersion compensation fiber (DCF) and single-mode fiber (SMF) with a small length difference are served as the two unbalanced arms of the RF interferometer. The induced differential chromatic dispersion transfers the wavelength shift of the FBG to the change of the RF phase difference between the two interferometric carriers, which ultimately leads to the variation of the RF signal intensity. An interrogation of a strain-turned FBG was accomplished and a maximum sensitivity of 0.00835  a.u./με was obtained, which can easily be further improved by more than two orders of magnitude through various fiber dispersion components. Finally, the stability of the interrogation was tested.

  19. Enabling technologies for fiber optic sensing

    Science.gov (United States)

    Ibrahim, Selwan K.; Farnan, Martin; Karabacak, Devrez M.; Singer, Johannes M.

    2016-04-01

    In order for fiber optic sensors to compete with electrical sensors, several critical parameters need to be addressed such as performance, cost, size, reliability, etc. Relying on technologies developed in different industrial sectors helps to achieve this goal in a more efficient and cost effective way. FAZ Technology has developed a tunable laser based optical interrogator based on technologies developed in the telecommunication sector and optical transducer/sensors based on components sourced from the automotive market. Combining Fiber Bragg Grating (FBG) sensing technology with the above, high speed, high precision, reliable quasi distributed optical sensing systems for temperature, pressure, acoustics, acceleration, etc. has been developed. Careful design needs to be considered to filter out any sources of measurement drifts/errors due to different effects e.g. polarization and birefringence, coating imperfections, sensor packaging etc. Also to achieve high speed and high performance optical sensing systems, combining and synchronizing multiple optical interrogators similar to what has been used with computer/processors to deliver super computing power is an attractive solution. This path can be achieved by using photonic integrated circuit (PIC) technology which opens the doors to scaling up and delivering powerful optical sensing systems in an efficient and cost effective way.

  20. Intelligence, previous convictions and interrogative suggestibility: a path analysis of alleged false-confession cases.

    Science.gov (United States)

    Sharrock, R; Gudjonsson, G H

    1993-05-01

    The main purpose of this study was to investigate the relationship between interrogative suggestibility and previous convictions among 108 defendants in criminal trials, using a path analysis technique. It was hypothesized that previous convictions, which may provide defendants with interrogative experiences, would correlate negatively with 'shift' as measured by the Gudjonsson Suggestibility Scale (Gudjonsson, 1984a), after intelligence and memory had been controlled for. The hypothesis was partially confirmed and the theoretical and practical implications of the findings are discussed.

  1. Can You Believe It? 12-Month-Olds Use Word Order to Distinguish between Declaratives and Polar Interrogatives

    Science.gov (United States)

    Geffen, Susan; Mintz, Toben H.

    2015-01-01

    Word order is a core mechanism for conveying syntactic structure, yet interrogatives usually disrupt canonical word orders. For example, in English, polar interrogatives typically invert the subject and auxiliary verb and insert an utterance-initial "do" if no auxiliary is present. These word order patterns result from differences in the…

  2. Detection of actinides with an electron accelerator by active photoneutron interrogation measurements

    International Nuclear Information System (INIS)

    Sari, A.; Carrel, F.; Gmar, M.; Laine, F.; Normand, S.; Lyoussi, A.

    2012-01-01

    The solution for management of a nuclear waste package is chosen according to its radiological characteristics. One of the most important of these features is the α-activity which is due to actinides ( 235 U, 238 U, 239 Pu, etc.) If non-destructive passive methods are not sufficient to quantify the latter, non-destructive active methods based on the fission process represent a solution of interest. First, these methods consist in irradiating a package in order to induce fission reactions on the actinides, and then, to detect the prompt and delayed particles which are emitted following these reactions. Our aim is to conduct neutron interrogation measurements on nuclear waste packages using an electron accelerator as a photoneutron generator. One of the main interests of this approach is that the intensity of the neutron flux can be one or two orders of magnitude higher than the one delivered by a deuterium-tritium generator. With the objective of improving nuclear waste characterization, the development of this method could enable the integration of three complementary techniques on a single measurement cell (active neutron interrogation, active photon interrogation, and high-energy imaging). In this paper, simulation and experimental results are presented. A simulation study using MCNPX has been conducted in order to determine the characteristics of the photoneutron flux emitted by the electron accelerator of the SAPHIR facility owned by CEA LIST. Energy spectra, angular distribution and intensity of the photoneutron flux have been obtained. A photoneutron interrogation measurement cell based on this accelerator has been built and assessed by carrying out measurements on uranium samples. Delayed gamma-ray spectra have been acquired and enabled to confirm the experimental feasibility of our method. (authors)

  3. Perioperative Interrogation of St. Jude Cardiovascular Implantable Electronic Devices: A Guide for Anesthesiologists.

    Science.gov (United States)

    Cronin, Brett; Essandoh, Michael K

    2018-04-01

    Feelings of trepidation or uncertainty regarding cardiovascular implantable electronic devices (CIEDs) in the perioperative period can often be mitigated by a thorough knowledge of societal recommendations, recommended management options, and familiarity with CIEDs. Given that effective interpretation of an interrogation report is vital to determining perioperative management options and applying societal recommendations, the creation and interpretation of St. Jude CIED interrogation reports are discussed. In an effort to increase the familiarity with St. Jude transvenous CIEDs amongst anesthesiologists, basic programming of a St. Jude pacemaker and implantable cardioverter defibrillator (ICD) also are described. Published by Elsevier Inc.

  4. Long fiber Bragg grating sensor interrogation using discrete-time microwave photonic filtering techniques.

    Science.gov (United States)

    Ricchiuti, Amelia Lavinia; Barrera, David; Sales, Salvador; Thevenaz, Luc; Capmany, José

    2013-11-18

    A novel technique for interrogating photonic sensors based on long fiber Bragg gratings (FBGs) is presented and experimentally demonstrated, dedicated to detect the presence and the precise location of several spot events. The principle of operation is based on a technique used to analyze microwave photonics (MWP) filters. The long FBGs are used as quasi-distributed sensors. Several hot-spots can be detected along the FBG with a spatial accuracy under 0.5 mm using a modulator and a photo-detector (PD) with a modest bandwidth of less than 1 GHz. The proposed interrogation system is intrinsically robust against environmental changes.

  5. Pulsed THZ Interrogation of Sofi With Knit Lines in 2D

    National Research Council Canada - National Science Library

    Banks, H. T; Gibson, N. L; Winfree, W. P

    2006-01-01

    This paper examines the scattering effect of knit lines and voids in SOFI through simulations of THz interrogation at normal and non-normal angles of incidence and using focused and non-focused single-cycle plane waves...

  6. High-fidelity MCNP modeling of a D-T neutron generator for active interrogation of special nuclear material

    International Nuclear Information System (INIS)

    Katalenich, Jeff; Flaska, Marek; Pozzi, Sara A.; Hartman, Michael R.

    2011-01-01

    Fast and robust methods for interrogation of special nuclear material (SNM) are of interest to many agencies and institutions in the United States. It is well known that passive interrogation methods are typically sufficient for plutonium identification because of a relatively high neutron production rate from 240 Pu . On the other hand, identification of shielded uranium requires active methods using neutron or photon sources . Deuterium-deuterium (2.45 MeV) and deuterium-tritium (14.1 MeV) neutron-generator sources have been previously tested and proven to be relatively reliable instruments for active interrogation of nuclear materials . In addition, the newest generators of this type are small enough for applications requiring portable interrogation systems. Active interrogation techniques using high-energy neutrons are being investigated as a method to detect hidden SNM in shielded containers . Due to the thickness of some containers, penetrating radiation such as high-energy neutrons can provide a potential means of probing shielded SNM. In an effort to develop the capability to assess the signal seen from various forms of shielded nuclear materials, University of Michigan Neutron Science Laboratory's D-T neutron generator and its shielding were accurately modeled in MCNP. The generator, while operating at nominal power, produces approximately 1x10 10 neutrons/s, a source intensity which requires a large amount of shielding to minimize the dose rates around the generator. For this reason, the existing shielding completely encompasses the generator and does not include beam ports. Therefore, several MCNP simulations were performed to estimate the yield of uncollided 14.1-MeV neutrons from the generator for active interrogation experiments. Beam port diameters of 5, 10, 15, 20, and 25 cm were modeled to assess the resulting neutron fluxes. The neutron flux outside the beam ports was estimated to be approximately 2x10 4 n/cm 2 s.

  7. Interrogating scarcity: how to think about ‘resource-scarce settings’

    Science.gov (United States)

    Schrecker, Ted

    2013-01-01

    The idea of resource scarcity permeates health ethics and health policy analysis in various contexts. However, health ethics inquiry seldom asks—as it should—why some settings are ‘resource-scarce’ and others not. In this article I describe interrogating scarcity as a strategy for inquiry into questions of resource allocation within a single political jurisdiction and, in particular, as an approach to the issue of global health justice in an interconnected world. I demonstrate its relevance to the situation of low- and middle-income countries (LMICs) with brief descriptions of four elements of contemporary globalization: trade agreements; the worldwide financial marketplace and capital flight; structural adjustment; imperial geopolitics and foreign policy. This demonstration involves not only health care, but also social determinants of health. Finally, I argue that interrogating scarcity provides the basis for a new, critical approach to health policy at the interface of ethics and the social sciences, with specific reference to market fundamentalism as the value system underlying contemporary globalization. PMID:22899597

  8. Spectral Doppler interrogation of the patent foramen ovale-a window to left heart hemodynamics.

    Science.gov (United States)

    Fadel, Bahaa M; Husain, Aysha; Bakarman, Hatem; Dahdouh, Ziad; Salvo, Giovanni Di; Mohty, Dania

    2015-02-01

    Spectral Doppler interrogation of flow across a patent foramen ovale (PFO) allows recording of the instantaneous pressure gradient between left and right atrium (RA). The assessment of RA pressure using the size and collapsibility of the inferior vena cava would thus allow estimation of left atrial (LA) pressure. In this article, we illustrate the value of spectral Doppler interrogation of flow across the PFO by transthoracic echocardiography as a novel and simple tool for the assessment of LA pressure and left cardiac hemodynamics in addition to the conventional noninvasive parameters. © 2014, Wiley Periodicals, Inc.

  9. Demonstration of an ultrasensitive refractive-index plasmonic sensor by enabling its quadrupole resonance in phase interrogation.

    Science.gov (United States)

    Lee, Hsin-Cheng; Li, Chung-Tien; Chen, How-Foo; Yen, Ta-Jen

    2015-11-15

    We present an ultrasensitive plasmonic sensing system by introducing a nanostructured X-shaped plasmonic sensor (XPS) and measuring its localized optical properties in phase interrogation. Our tailored XPS exhibits two major resonant modes of a low-order dipole and a high-order quadrupole, between which the quadrupole resonance allows an ultrahigh sensitivity, due to its higher quality factor. Furthermore, we design an in-house common-path phase-interrogation system, in contrast to conventional wavelength-interrogation methods, to achieve greater sensing capability. The experimental measurement shows that the sensing resolution of the XPS reaches 1.15×10(-6) RIU, not only two orders of magnitude greater than the result of the controlled extinction measurement (i.e., 9.90×10(-5) RIU), but also superior than current reported plasmonic sensors.

  10. Knowingly but naively: The overpowering influence of innocence on interrogation rights decision-making.

    Science.gov (United States)

    Scherr, Kyle C; Normile, Christopher J; Bierstetel, Sabrina J; Franks, Andrew S; Hawkins, Ian

    2018-02-01

    Most suspects waive the guaranteed protections that interrogation rights afford them against police intimidation. One factor thought to motivate suspects' inclination to waive their rights stems from the acquiescence bias whereby suspects mindlessly comply with interrogators' requests. However, research bearing on the phenomenology of innocence has demonstrated the power of innocents' mindset, which could motivate some innocent suspects to waive their rights knowingly (instead of mindlessly complying). To test these ideas, participants (N = 178) were (a) rightfully (guilty) or wrongfully (innocent) accused of wrongdoing during an experimental session, (b) administered 1 of 2 forms that by signing either waived or invoked their rights to a student advocate, and (c) given questions to assess their degree of knowing during the decision-making process (i.e., extent to which individuals were cognizant of their decisions). Results demonstrated that unknowing innocent and guilty individuals tended to passively comply, engaging in a pre-interrogation acquiescence bias by signing waive and invoke forms at similar rates. But, as participants became more cognizant of their decisions, they acquiesced at lower rates and their change from acquiescence differed depending on their status. As innocents became more cognizant, they signed the waiver form at higher rates than the invoke form, thereby demonstrating that innocence can motivate some suspects to knowingly forgo their rights. Conversely, as guilty individuals became more cognizant, they signed the invoke form at higher rates than the waiver form. These findings have implications for reforming pre-interrogation protocols, protecting suspects' civil liberties, and preventing innocents from offering false self-incriminating evidence. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  11. A wireless interrogation system exploiting narrowband acoustic resonator for remote physical quantity measurement

    Energy Technology Data Exchange (ETDEWEB)

    Friedt, J.-M [SENSeOR, 32 Avenue de l' Observatoire, 25044 Besancon (France); Droit, C.; Martin, G.; Ballandras, S. [Department of Time and Frequency, FEMTO-ST, 32 Avenue de l' Observatoire, 25044 Besancon (France)

    2010-01-15

    Monitoring physical quantities using acoustic wave devices can be advantageously achieved using the wave characteristic dependence to various parametric perturbations (temperature, stress, and pressure). Surface acoustic wave (SAW) resonators are particularly well suited to such applications as their resonance frequency is directly influenced by these perturbations, modifying both the phase velocity and resonance conditions. Moreover, the intrinsic radio frequency (rf) nature of these devices makes them ideal for wireless applications, mainly exploiting antennas reciprocity and piezoelectric reversibility. In this paper, we present a wireless SAW sensor interrogation unit operating in the 434 MHz centered ISM band--selected as a tradeoff between antenna dimensions and electromagnetic wave penetration in dielectric media--based on the principles of a frequency sweep network analyzer. We particularly focus on the compliance with the ISM standard which reveals complicated by the need for switching from emission to reception modes similarly to radar operation. In this matter, we propose a fully digital rf synthesis chain to develop various interrogation strategies to overcome the corresponding difficulties and comply with the above-mentioned standard. We finally assess the reader interrogation range, accuracy, and dynamics.

  12. A wireless interrogation system exploiting narrowband acoustic resonator for remote physical quantity measurement

    International Nuclear Information System (INIS)

    Friedt, J.-M; Droit, C.; Martin, G.; Ballandras, S.

    2010-01-01

    Monitoring physical quantities using acoustic wave devices can be advantageously achieved using the wave characteristic dependence to various parametric perturbations (temperature, stress, and pressure). Surface acoustic wave (SAW) resonators are particularly well suited to such applications as their resonance frequency is directly influenced by these perturbations, modifying both the phase velocity and resonance conditions. Moreover, the intrinsic radio frequency (rf) nature of these devices makes them ideal for wireless applications, mainly exploiting antennas reciprocity and piezoelectric reversibility. In this paper, we present a wireless SAW sensor interrogation unit operating in the 434 MHz centered ISM band--selected as a tradeoff between antenna dimensions and electromagnetic wave penetration in dielectric media--based on the principles of a frequency sweep network analyzer. We particularly focus on the compliance with the ISM standard which reveals complicated by the need for switching from emission to reception modes similarly to radar operation. In this matter, we propose a fully digital rf synthesis chain to develop various interrogation strategies to overcome the corresponding difficulties and comply with the above-mentioned standard. We finally assess the reader interrogation range, accuracy, and dynamics.

  13. Adaptive image interrogation for PIV : Application to compressible flows and interfaces

    NARCIS (Netherlands)

    Theunissen, R.

    2010-01-01

    As an experimental tool, Particle Image Velocimetry has quickly superseded traditional point-wise measurements. The inherent image processing has become standardized though the performances are strongly dependent on user experience. Moreover, the arduously selected image interrogation parameters are

  14. Learning about Posterior Probability: Do Diagrams and Elaborative Interrogation Help?

    Science.gov (United States)

    Clinton, Virginia; Alibali, Martha W.; Nathan, Mitchell J.

    2016-01-01

    To learn from a text, students must make meaningful connections among related ideas in that text. This study examined the effectiveness of two methods of improving connections--elaborative interrogation and diagrams--in written lessons about posterior probability. Undergraduate students (N = 198) read a lesson in one of three questioning…

  15. Interrogative pressure in simulated forensic interviews: the effects of negative feedback.

    Science.gov (United States)

    McGroarty, Allan; Baxter, James S

    2007-08-01

    Much experimental research on interrogative pressure has concentrated on the effects of leading questions, and the role of feedback in influencing responses in the absence of leading questions has been neglected by comparison. This study assessed the effect of negative feedback and the presence of a second interviewer on interviewee responding in simulated forensic interviews. Participants viewed a videotape of a crime, answered questions about the clip and were requestioned after receiving feedback. Compared with neutral feedback, negative feedback resulted in more response changes, higher reported state anxiety and higher ratings of interview difficulty. These results are consistent with Gudjonsson and Clark's (1986) model of interrogative suggestibility. The presence and involvement of a second interviewer did not significantly affect interviewee responding, although trait anxiety scores were elevated when a second interviewer was present. The theoretical and applied implications of these findings are considered.

  16. Psychologists and detainee interrogations: key decisions, opportunities lost, and lessons learned.

    Science.gov (United States)

    Pope, Kenneth S

    2011-01-01

    After the 9-11 terrorist attacks, U.S. psychologists faced hard choices about what roles, if any, were appropriate for psychologists in the detainee interrogations conducted in settings such as the Bagram Airbase, the Abu Ghraib Prison, and the Guantanamo Bay Detention Camps. The American Psychological Association (APA) sparked intense controversy with its policies and public statements. This article reviews APA decisions, documents, and public statements in this area, in the context of major criticisms and responses to those criticisms. The review focuses on key issues: how the APA created and reported policies in the areas of ethics and national security; transparency; psychologists' professional identities; psychologists' qualifications; ethical-legal conflicts; policies opposing torture; interpretations of avoiding harm; and effective interrogations. It suggests lessons learned, missed opportunities, and questions in need of a fresh approach. © 2011 by Annual Reviews. All rights reserved

  17. Examining the role of interrogative suggestibility in Miranda rights comprehension in adolescents.

    Science.gov (United States)

    McLachlan, Kaitlyn; Roesch, Ronald; Douglas, Kevin S

    2011-06-01

    This study aimed to further clarify the association between interrogative suggestibility and Miranda rights comprehension in adolescents; in particular, we examined whether intellectual ability (IQ) serves as a mediator of this relationship. Participants completed Grisso's Miranda Instruments, the Wechsler Abbreviated Scale of Intelligence, and the Gudjonsson Suggestibility Scale. Many youth demonstrated poor comprehension of their rights, particularly younger and less intellectually capable adolescents. Both yield and shift components of interrogative suggestibility were inversely related to rights comprehension; however, IQ fully mediated these relationships. Neither demographic variables (gender, ethnicity, socio-economic status after controlling for IQ, and English as a second language (ESL) status) nor previous police experience were significantly associated with rights comprehension in the present sample. The implications of these findings are discussed.

  18. A Fiber Bragg Grating Sensor Interrogation System Based on a Linearly Wavelength-Swept Thermo-Optic Laser Chip

    Science.gov (United States)

    Lee, Hyung-Seok; Lee, Hwi Don; Kim, Hyo Jin; Cho, Jae Du; Jeong, Myung Yung; Kim, Chang-Seok

    2014-01-01

    A linearized wavelength-swept thermo-optic laser chip was applied to demonstrate a fiber Bragg grating (FBG) sensor interrogation system. A broad tuning range of 11.8 nm was periodically obtained from the laser chip for a sweep rate of 16 Hz. To measure the linear time response of the reflection signal from the FBG sensor, a programmed driving signal was directly applied to the wavelength-swept laser chip. The linear wavelength response of the applied strain was clearly extracted with an R-squared value of 0.99994. To test the feasibility of the system for dynamic measurements, the dynamic strain was successfully interrogated with a repetition rate of 0.2 Hz by using this FBG sensor interrogation system. PMID:25177803

  19. Age and interviewer behavior as predictors of interrogative suggestibility.

    Science.gov (United States)

    Dukala, Karolina; Polczyk, Romuald

    2014-05-01

    The main objective was to explore the influence of interviewer behavior-abrupt versus friendly-and the age of participants on interrogative suggestibility. The study involved 42 young adults and 50 elderly participants. The Gudjonsson Suggestibility Scale 2 was used. Data analysis involved a 2-factor between-subjects design (interviewer behavior × age) and mediation analysis. The scores of elderly participants were significantly lower than younger adults on memory indices and significantly higher on some suggestibility indexes. Some suggestibility indices in the abrupt experimental condition were higher than those in the friendly experimental condition. Elderly participants who were interviewed under the abrupt condition were more likely to change their answers after receiving negative feedback than younger adults. Memory quality was a mediator of the relationship between age and the tendency to yield to suggestive questions. Self-appraisal of memory was a mediator between both age and interviewer behavior and the tendency to change answers after negative feedback. Mechanisms of the relationship between age, interviewer behavior, and suggestibility are discussed on the basis of the mediational analyses. The findings suggest that a friendly manner should be adopted when interrogating witnesses.

  20. The Fight for the High Ground: The U.S. Army and Interrogation during Operation Iraqi Freedom I, May 2003-April 2004

    Science.gov (United States)

    2009-06-12

    Captain Wood has stated that she " plagiarized " the interrogation policy of TF 121 (according to news reporting, the name of this SMU task force at...the time of her plagiarization ) to create a draft interrogation policy for her own interrogators at Abu Ghraib. 85 She then submitted this draft...29 Ibid. 30 Lieutenant Colonel Dean Bland, The Abu Ghraib Scandal: Impact on the Army Profession and the Intelligence Process, Academic Research

  1. A Kinematically Beamed, Low Energy Pulsed Neutron Source for Active Interrogation

    International Nuclear Information System (INIS)

    Dietrich, D.; Hagmann, C.; Kerr, P.; Nakae, L.; Rowland, M.; Snyderman, N.; Stoeffl, W.; Hamm, R.

    2004-01-01

    We are developing a new active interrogation system based on a kinematically focused low energy neutron beam. The key idea is that one of the defining characteristics of SNM (Special Nuclear Materials) is the ability for low energy or thermal neutrons to induce fission. Thus by using low energy neutrons for the interrogation source we can accomplish three goals, (1) Energy discrimination allows us to measure the prompt fast fission neutrons produced while the interrogation beam is on; (2) Neutrons with an energy of approximately 60 to 100 keV do not fission 238U and Thorium, but penetrate bulk material nearly as far as high energy neutrons do and (3) below about 100keV neutrons lose their energy by kinematical collisions rather than via the nuclear (n,2n) or (n,n') processes thus further simplifying the prompt neutron induced background. 60 keV neutrons create a low radiation dose and readily thermal capture in normal materials, thus providing a clean spectroscopic signature of the intervening materials. The kinematically beamed source also eliminates the need for heavy backward and sideway neutron shielding. We have designed and built a very compact pulsed neutron source, based on an RFQ proton accelerator and a lithium target. We are developing fast neutron detectors that are nearly insensitive to the ever-present thermal neutron and neutron capture induced gamma ray background. The detection of only a few high energy fission neutrons in time correlation with the linac pulse will be a clear indication of the presence of SNM

  2. Guidelines for calculating and enhancing detection efficiency of PIT tag interrogation systems

    Science.gov (United States)

    Connolly, Patrick J.

    2010-01-01

    With increasing use of passive integrated transponder (PIT) tags and reliance on stationary PIT tag interrogation systems to monitor fish populations, guidelines are offered to inform users how best to use limited funding and human resources to create functional systems that maximize a desired level of detection and precision. The estimators of detection efficiency and their variability as described by Connolly et al. (2008) are explored over a span of likely performance metrics. These estimators were developed to estimate detection efficiency without relying on a known number of fish passing the system. I present graphical displays of the results derived from these estimators to show the potential efficiency and precision to be gained by adding an array or by increasing the number of PIT-tagged fish expected to move past an interrogation system.

  3. Toward multi-area distributed network of implanted neural interrogators

    Science.gov (United States)

    Powell, Marc P.; Hou, Xiaoxiao; Galligan, Craig; Ashe, Jeffrey; Borton, David A.

    2017-08-01

    As we aim to improve our understanding of the brain, it is critical that researchers have simultaneous multi-area, large-scale access to the brain. Information processing in the brain occurs through close and distant coupling of functional sub-domains, as opposed to within isolated single neurons. However, commercially available neural interfaces capable of sensing electrophysiology of single neurons, currently allow access to only a small, mm3 volume of cortical cells, are not scalable to recording from orders of magnitude more neurons, and leverage bulky, skull mounted hardware and cabling sensitive to relative movements of the skull and brain. In this work, we propose a system capable of recording from many individual distributed neural interrogator nodes, untethered from any external electronics. Using an array of epidural inductive coils to wirelessly power the implanted electronics, the system is intended to be agnostic to the surgical placement of any individual node. Here, we demonstrate the ability to transmit nearly 15mW of power with greater than 50% power transfer efficiency, benchtop testing of individual subcircuit system components showing successful digitization of neural signals, and wireless transmission currently supporting a data rate of 3.84Mbps. We leverage a software defined radio based RF receiver to demodulate the data which can be stored in memory for later retrieval. Finally, we introduce a packaging technology capable of isolating active electronics from the surrounding tissue while providing capability for electrical feed-through assemblies for external neural interfacing. We expect, based on the presented preliminary findings, that the system can be integrated into a platform technology for the study of the intricate interactions between cortical domains.

  4. Material Identification Technology (MIT) concept technical feasibility study

    International Nuclear Information System (INIS)

    Jones, J.L.; Harker, Y.D.; Yoon, W.Y.; Johnson, L.O.

    1993-09-01

    The Idaho National Engineering Laboratory (INEL) has initiated the design and development of a novel pulsed accelerator-based, active interrogation concept. The proposed concept, referred to as the Material Identification Technology (MIT), enables rapid (between accelerator pulses), non-destructive, elemental composition analysis of both nuclear and non-nuclear materials. Applications of this technique include material monitoring in support of counter-proliferation activities, such as export controls (at domestic and international inspection locations), SNM controls, nuclear weapon dismantlement, and chemical weapon verification. Material Identification Technology combines a pulsed, X-ray source (an electron accelerator) and a gamma detection system. The accelerator must maximize neutron production (pulse width, beam current, beam energy, and repetition rate) and minimize photon dose to the object. Current available accelerator technology can meet these requirements. The detection system must include detectors which provide adequate gamma energy resolution capability, rapid recovery after the initial X-ray interrogation pulse, and multiple single gamma event detection between accelerator pulses. Further research is required to develop the detection system. This report provides the initial feasibility assessment of the MIT concept

  5. The captive brain: torture and the neuroscience of humane interrogation.

    Science.gov (United States)

    O'Mara, S

    2018-02-01

    Despite it being abhorrent and illegal, torture is sometimes employed for information gathering. However, the extreme stressors employed during torture force the brain away from the relatively narrow, adaptive range of function it operates within. Torture degrades signal-to-noise ratios of information yield and increases false positive discovery rates. As a discovery methodology, torture fails basic tests of veridical, reliable and replicable information discovery. Torture fails during interrogation because it is an assault on our core integrated, social, psychological and neural functioning. There is a need for a profound cultural shift regarding torture, recognizing that torture impairs, rather than facilitates, investigations and truth-finding. Rising to this challenge will increase operational effectiveness, eliminate prisoner abuse and torment, and aid veridical and actionable information gathering. Policy regarding prisoner and detainee interrogation need to be refocused as a behavioural and brain sciences problem, and not simply treated as a legal, ethical or philosophical problem. Getting the science, ethics and practice in line is a challenge, but it can and should be done.

  6. Optical Stabilization of a Microwave Oscillator for Fountain Clock Interrogation.

    Science.gov (United States)

    Lipphardt, Burghard; Gerginov, Vladislav; Weyers, Stefan

    2017-04-01

    We describe an optical frequency stabilization scheme of a microwave oscillator that is used for the interrogation of primary cesium fountain clocks. Because of its superior phase noise properties, this scheme, which is based on an ultrastable laser and a femtosecond laser frequency comb, overcomes the frequency instability limitations of fountain clocks given by the previously utilized quartz-oscillator-based frequency synthesis. The presented scheme combines the transfer of the short-term frequency instability of an optical cavity and the long-term frequency instability of a hydrogen maser to the microwave oscillator and is designed to provide continuous long-term operation for extended measurement periods of several weeks. The utilization of the twofold stabilization scheme on the one hand ensures the referencing of the fountain frequency to the hydrogen maser frequency and on the other hand results in a phase noise level of the fountain interrogation signal, which enables fountain frequency instabilities at the 2.5 ×10 -14 (τ/s) -1/2 level that are quantum projection noise limited.

  7. Determination of Interrogating Frequencies to Maximize Electromagnetic Backscatter from Objects with Material Coatings

    National Research Council Canada - National Science Library

    Banks, H. T; Ito, K; Toivanen, J

    2005-01-01

    .... Based on the radar cross section and a reflection coefficient, optimization problems are formulated for evaders and interrogators leading to optimal material parameters for the coating and optimal...

  8. Cellular Interrogation: Exploiting Cell-to-Cell Variability to Discriminate Regulatory Mechanisms in Oscillatory Signalling.

    Science.gov (United States)

    Estrada, Javier; Andrew, Natalie; Gibson, Daniel; Chang, Frederick; Gnad, Florian; Gunawardena, Jeremy

    2016-07-01

    The molecular complexity within a cell may be seen as an evolutionary response to the external complexity of the cell's environment. This suggests that the external environment may be harnessed to interrogate the cell's internal molecular architecture. Cells, however, are not only nonlinear and non-stationary, but also exhibit heterogeneous responses within a clonal, isogenic population. In effect, each cell undertakes its own experiment. Here, we develop a method of cellular interrogation using programmable microfluidic devices which exploits the additional information present in cell-to-cell variation, without requiring model parameters to be fitted to data. We focussed on Ca2+ signalling in response to hormone stimulation, which exhibits oscillatory spiking in many cell types and chose eight models of Ca2+ signalling networks which exhibit similar behaviour in simulation. We developed a nonlinear frequency analysis for non-stationary responses, which could classify models into groups under parameter variation, but found that this question alone was unable to distinguish critical feedback loops. We further developed a nonlinear amplitude analysis and found that the combination of both questions ruled out six of the models as inconsistent with the experimentally-observed dynamics and heterogeneity. The two models that survived the double interrogation were mathematically different but schematically identical and yielded the same unexpected predictions that we confirmed experimentally. Further analysis showed that subtle mathematical details can markedly influence non-stationary responses under parameter variation, emphasising the difficulty of finding a "correct" model. By developing questions for the pathway being studied, and designing more versatile microfluidics, cellular interrogation holds promise as a systematic strategy that can complement direct intervention by genetics or pharmacology.

  9. Interrogation and mitigation of polarization effects for standard and birefringent FBGs

    Science.gov (United States)

    Ibrahim, Selwan K.; Van Roosbroeck, Jan; O'Dowd, John A.; Van Hoe, Bram; Lindner, Eric; Vlekken, Johan; Farnan, Martin; Karabacak, Devrez M.; Singer, Johannes M.

    2016-05-01

    Optical sensors based on Fiber Bragg Gratings (FBGs) are used in several applications and industries. Several inscription techniques and type of fibers can be used. However, depending on the writing process, type of fiber used and the packaging of the sensor a Polarization Dependent Frequency Shift (PDFS) can often be observed with polarized tunable laser based optical interrogators. Here we study the PDFS of the FBG peak for the different FBG types. A PDFS of 20pm was observed across the FBGs. To mitigate and reduce this effect we propose a polarization mitigation technique which relies on a synchronous polarization switch to reduce the effect typically by a factor greater than 4. In other scenarios the sensor itself is designed to be birefringent (Bi-FBG) to allow pressure and/or simultaneous temperature and strain measurements. Using the same polarization switch we demonstrate how we can interrogate the Bi-FBGs with high accuracy to enable high performance of such sensors to be achievable.

  10. A l-nCi/g sensitivity transuranic waste assay system using pulsed neutron interrogation

    International Nuclear Information System (INIS)

    Kunz, W.E.; Atencio, J.D.; Caldwell, J.T.

    1980-01-01

    We have developed a pulsed thermal neutron interrogation system and have demonstrated a sub-1-nCi/g assay sensitivity for high density TRU wastes contained in 200-liter barrels. We detect prompt fission neutrons, resulting in greatly enhanced sensitivity compared to techniques in which delayed fission neutrons are detected. We observe a linear assay response over at least three orders of magnitude in 235 U (or 239 Pu) mass. We also have measured a flat (to +-10%) interrogation flux profile throughout the volume of a 200-liter barrel filled with 200 kg of sand and vermiculite, which indicates flatness of response to fissile material at different locations within the barrel

  11. Interrogating personhood and dementia

    Science.gov (United States)

    Higgs, Paul; Gilleard, Chris

    2016-01-01

    ABSTRACT Objectives: To interrogate the concept of personhood and its application to care practices for people with dementia. Method: We outline the work of Tom Kitwood on personhood and relate this to conceptualisations of personhood in metaphysics and in moral philosophy. Results: The philosophical concept of personhood has a long history. The metaphysical tradition examines the necessary and sufficient qualities that make up personhood such as agency, consciousness, identity, rationality and second-order reflexivity. Alternative viewpoints treat personhood as a matter of degree rather than as a superordinate category. Within moral philosophy personhood is treated as a moral status applicable to some or to all human beings. Conclusion: In the light of the multiple meanings attached to the term in both metaphysics and moral philosophy, personhood is a relatively unhelpful concept to act as the foundation for developing models and standards of care for people with dementia. Care, we suggest, should concentrate less on ambiguous and somewhat abstract terms such as personhood and focus instead on supporting people's existing capabilities, while minimising the harmful consequences of their incapacities. PMID:26708149

  12. Cyborgs, desiring-machines, bodies without organs, and Westworld: Interrogating academic writing and scholarly identity

    Directory of Open Access Journals (Sweden)

    Deborah M. Netolicky

    2017-07-01

    Full Text Available This paper fashions a lens through which to view scholarly identity and the experience of academic writing. The lens of inquiry I apply is the metaphor of Season 1 of sci-fi HBO television show Westworld and its characters, especially its cyborg protagonist Dolores. Thrumming like electric currents through this lens of inquiry are Haraway’s theorization of the cyborg, the fictional worlds of science fiction and Wonderland, my own lived experience, and Deleuze and Guattari’s desiring-machines and bodies without organs. I engage in the cyborgic technology of writing in order to playfully explore what it means to be a cyborg academic operating in intersecting machinic worlds. I ask: Can we listen to our internal voices and write our own stories? Can we burn the world clean with our scholarship and the ways in which we interrogate ingrained and expected practices?

  13. The History of MIS-Y: U.S. Strategic Interrogation During World War II

    National Research Council Canada - National Science Library

    Kleinman, Steven M

    2002-01-01

    As World War II unfolded, the strategic interrogation programs established by the British, German, and American forces evolved into robust collection entities that proved to be a unique source of critical intelligence...

  14. Educing Information - Interrogation: Science and Art, Foundations for the Future

    Science.gov (United States)

    2006-12-01

    imprisonment as an integral component of the inquisitor’s interrogation strategy…. [C]oupled if necessary, with hunger , shackles, and torture…[it...computer science with a concentration in machine intelligence and cognition, and minors in neuropsychology and developmental psychology, from The George...a solid theoretical base, then a signifi cant research investment into the underlying neuropsychological mechanisms of deception must be made before

  15. Interrogation of Detainees: Requirements of the Detainee Treatment Act

    Science.gov (United States)

    2009-08-26

    providing legal protections and assistance to U.S. personnel subjected to legal action on account of their involvement in the authorized interrogation of...types of actions prohibited by the U.S. Constitution. There is some legal dispute as to whether CAT Article 16, as read in light of U.S. reservations... unconstitutionally harsh than it would use to assess whether those same techniques were unconstitutional if employed against an enemy combatant in a war zone

  16. Laser interrogation of latent vehicle registration number

    Energy Technology Data Exchange (ETDEWEB)

    Russo, R.E. [Lawrence Berkeley Lab., CA (United States). Energy and Environment Div.]|[Lawrence Livermore National Lab., CA (United States). Forensic Science Center; Pelkey, G.E. [City of Livermore Police Dept., CA (United States); Grant, P.; Whipple, R.E.; Andresen, B.D. [Lawrence Livermore National Lab., CA (United States). Forensic Science Center

    1994-09-01

    A recent investigation involved automobile registration numbers as important evidentiary specimens. In California, as in most states, small, thin metallic decals are issued to owners of vehicles each year as the registration is renewed. The decals are applied directly to the license plate of the vehicle and typically on top of the previous year`s expired decal. To afford some degree of security, the individual registration decals have been designed to tear easily; they cannot be separated from each other, but can be carefully removed intact from the metal license plate by using a razor blade. In September 1993, the City of Livermore Police Department obtained a blue 1993 California decal that had been placed over an orange 1992 decal. The two decals were being investigated as possible evidence in a case involving vehicle registration fraud. To confirm the suspicion and implicate a suspect, the department needed to known the registration number on the bottom (completely covered) 1992 decal. The authors attempted to use intense and directed light to interrogate the colored stickers. Optical illumination using a filtered white-light source partially identified the latent number. However, the most successful technique used a tunable dye laser pumped by a pulsed Nd:YAG laser. By selectively tuning the wavelength and intensity of the dye laser, backlit illumination of the decals permitted visualization of the underlying registration number through the surface of the top sticker. With optimally-tuned wavelength and intensity, 100% accuracy was obtained in identifying the sequence of latent characters. The advantage of optical techniques is their completely nondestructive nature, thus preserving the evidence for further interrogation or courtroom presentation.

  17. Performance of an optical identification and interrogation system

    Science.gov (United States)

    Venugopalan, A.; Ghosh, A. K.; Verma, P.; Cheng, S.

    2008-04-01

    A free space optics based identification and interrogation system has been designed. The applications of the proposed system lie primarily in areas which require a secure means of mutual identification and information exchange between optical readers and tags. Conventional RFIDs raise issues regarding security threats, electromagnetic interference and health safety. The security of RF-ID chips is low due to the wide spatial spread of radio waves. Malicious nodes can read data being transmitted on the network, if they are in the receiving range. The proposed system provides an alternative which utilizes the narrow paraxial beams of lasers and an RSA-based authentication scheme. These provide enhanced security to communication between a tag and the base station or reader. The optical reader can also perform remote identification and the tag can be read from a far off distance, given line of sight. The free space optical identification and interrogation system can be used for inventory management, security systems at airports, port security, communication with high security systems, etc. to name a few. The proposed system was implemented with low-cost, off-the-shelf components and its performance in terms of throughput and bit error rate has been measured and analyzed. The range of operation with a bit-error-rate lower than 10-9 was measured to be about 4.5 m. The security of the system is based on the strengths of the RSA encryption scheme implemented using more than 1024 bits.

  18. Integrated Box Interrogation System (IBIS) Preliminary Design Study

    International Nuclear Information System (INIS)

    Croft, Stephen; Martancik, David; Young, Brian; Chard MJ, Patrick; Estop J, Robert; Sheila Melton; Arnone, Gaetano J.

    2003-01-01

    Canberra Industries has won the tendered solicitation, INEEL/EST-99-00121 for boxed waste Nondestructive Assay Development and Demonstration. Canberra will provide the Integrated Box Interrogation System (IBIS) which is a suite of assay instrumentation and a data reduction system that addresses the measurement needs for Boxed Wastes identified in the solicitation and facilitates the associated experimental program and demonstration of system capability. The IBIS system will consist of the next generation CWAM system, i.e. CWAM II, which is a Scanning Passive/Active Neutron interrogation system which we will call a Box Segmented Neutron Scanner (BSNS), combined with a physically separate Box Segmented Gamma-ray Scanning (BSGS) system. These systems are based on existing hardware designs but will be tailored to the large sample size and enhanced to allow the program to evaluate the following measurement criteria:Characterization and correction for matrix heterogeneity Characterization of non-uniform radio-nuclide and isotopic compositions Assay of high density matrices (both high-Z and high moderator contents)Correction for radioactive material physical form - such as self shielding or multiplication effects due to large accumulations of radioactive materials.Calibration with a minimal set of reference standards and representative matrices.THis document summarizes the conceptual design parameters of the IBIS and indicates areas key to the success of the project where development is to be centered. The work presented here is a collaborative effort between scientific staff within Canberra and within the NIS-6 group at LANL

  19. Integrated Box Interrogation System (IBIS) Preliminary Design Study

    Energy Technology Data Exchange (ETDEWEB)

    DR. Stephen Croft; Mr. David Martancik; Dr. Brian Young; Dr. Patrick MJ Chard; Dr. Robert J Estop; Sheila Melton; Gaetano J. Arnone

    2003-01-13

    Canberra Industries has won the tendered solicitation, INEEL/EST-99-00121 for boxed waste Nondestructive Assay Development and Demonstration. Canberra will provide the Integrated Box Interrogation System (IBIS) which is a suite of assay instrumentation and a data reduction system that addresses the measurement needs for Boxed Wastes identified in the solicitation and facilitates the associated experimental program and demonstration of system capability. The IBIS system will consist of the next generation CWAM system, i.e. CWAM II, which is a Scanning Passive/Active Neutron interrogation system which we will call a Box Segmented Neutron Scanner (BSNS), combined with a physically separate Box Segmented Gamma-ray Scanning (BSGS) system. These systems are based on existing hardware designs but will be tailored to the large sample size and enhanced to allow the program to evaluate the following measurement criteria:Characterization and correction for matrix heterogeneity Characterization of non-uniform radio-nuclide and isotopic compositions Assay of high density matrices (both high-Z and high moderator contents)Correction for radioactive material physical form - such as self shielding or multiplication effects due to large accumulations of radioactive materials.Calibration with a minimal set of reference standards and representative matrices.THis document summarizes the conceptual design parameters of the IBIS and indicates areas key to the success of the project where development is to be centered. The work presented here is a collaborative effort between scientific staff within Canberra and within the NIS-6 group at LANL.

  20. Investigations of active interrogation techniques to detect special nuclear material in maritime environments: Standoff interrogation of small- and medium-sized cargo ships

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Thomas M., E-mail: millertm@ornl.gov; Patton, Bruce W.; Grogan, Brandon R.; Henkel, James J.; Murphy, Brian D.; Johnson, Jeffrey O.; Mihalczo, John T.

    2013-12-01

    In this work, several active interrogation (AI) sources are evaluated to determine their usefulness in detecting the presence of special nuclear material (SNM) in fishing trawlers, small cargo transport ships, and luxury yachts at large standoff distances from the AI source and detector. This evaluation is performed via computational analysis applying Monte Carlo methods with advanced variance reduction techniques. The goal is to determine the AI source strength required to detect the presence of SNM. The general conclusion of this study is that AI is not reliable when SNM is heavily shielded and not tightly coupled geometrically with the source and detector, to the point that AI should not be considered a via interrogation option in these scenarios. More specifically, when SNM is shielded by hydrogenous material large AI source strengths are required if detection is based on neutrons, which is not surprising. However, if the SNM is shielded by high-Z material the required AI source strengths are not significantly different if detection is based on neutrons or photons, which is somewhat surprising. Furthermore, some of the required AI source strengths that were calculated are very large. These results coupled with the realities of two ships moving independently at sea and other assumptions made during this analysis make the use of standoff AI in the maritime environment impractical.

  1. Investigations of active interrogation techniques to detect special nuclear material in maritime environments: Standoff interrogation of small- and medium-sized cargo ships

    International Nuclear Information System (INIS)

    Miller, Thomas M.; Patton, Bruce W.; Grogan, Brandon R.; Henkel, James J.; Murphy, Brian D.; Johnson, Jeffrey O.; Mihalczo, John T.

    2013-01-01

    In this work, several active interrogation (AI) sources are evaluated to determine their usefulness in detecting the presence of special nuclear material (SNM) in fishing trawlers, small cargo transport ships, and luxury yachts at large standoff distances from the AI source and detector. This evaluation is performed via computational analysis applying Monte Carlo methods with advanced variance reduction techniques. The goal is to determine the AI source strength required to detect the presence of SNM. The general conclusion of this study is that AI is not reliable when SNM is heavily shielded and not tightly coupled geometrically with the source and detector, to the point that AI should not be considered a via interrogation option in these scenarios. More specifically, when SNM is shielded by hydrogenous material large AI source strengths are required if detection is based on neutrons, which is not surprising. However, if the SNM is shielded by high-Z material the required AI source strengths are not significantly different if detection is based on neutrons or photons, which is somewhat surprising. Furthermore, some of the required AI source strengths that were calculated are very large. These results coupled with the realities of two ships moving independently at sea and other assumptions made during this analysis make the use of standoff AI in the maritime environment impractical

  2. The simultaneous neutron and photon interrogation method for fissile and non-fissile element separation in radioactive waste drums

    International Nuclear Information System (INIS)

    Jallu, F.; Lyoussi, A.; Passard, C.; Payan, E.; Recroix, H.; Nurdin, G.; Buisson, A.; Allano, J.

    2000-01-01

    Measuring α-emitters such as ( 234,235,236,238 U, 238,239,240,242,244 Pu, 237 Np, 241,243 Am, ...), in solid radioactive waste allows us to quantify the α-activity in a drum and then to classify it. The simultaneous photon and neutron interrogation experiment (SIMPHONIE) method dealt with in this paper, combines both active neutron interrogation and induced photofission interrogation techniques simultaneously. Its purpose is to quantify fissile ( 235 U, 239,241 Pu, ...) and non-fissile ( 236,238 U, 238,240 Pu, ...) elements separately in only one measurement. This paper presents the principle of the method, the experimental setup, and the first experimental results obtained using the DGA/ETCA Linac and MiniLinatron pulsed linear electron accelerators located at Arcueil, France. First studies were carried out with U and Pu bare samples

  3. Evaluation of fiber Bragg grating sensor interrogation using InGaAs linear detector arrays and Gaussian approximation on embedded hardware

    Science.gov (United States)

    Kumar, Saurabh; Amrutur, Bharadwaj; Asokan, Sundarrajan

    2018-02-01

    Fiber Bragg Grating (FBG) sensors have become popular for applications related to structural health monitoring, biomedical engineering, and robotics. However, for successful large scale adoption, FBG interrogation systems are as important as sensor characteristics. Apart from accuracy, the required number of FBG sensors per fiber and the distance between the device in which the sensors are used and the interrogation system also influence the selection of the interrogation technique. For several measurement devices developed for applications in biomedical engineering and robotics, only a few sensors per fiber are required and the device is close to the interrogation system. For these applications, interrogation systems based on InGaAs linear detector arrays provide a good choice. However, their resolution is dependent on the algorithms used for curve fitting. In this work, a detailed analysis of the choice of algorithm using the Gaussian approximation for the FBG spectrum and the number of pixels used for curve fitting on the errors is provided. The points where the maximum errors occur have been identified. All comparisons for wavelength shift detection have been made against another interrogation system based on the tunable swept laser. It has been shown that maximum errors occur when the wavelength shift is such that one new pixel is included for curve fitting. It has also been shown that an algorithm with lower computation cost compared to the more popular methods using iterative non-linear least squares estimation can be used without leading to the loss of accuracy. The algorithm has been implemented on embedded hardware, and a speed-up of approximately six times has been observed.

  4. Lawfulness of Interrogation Techniques under the Geneva Conventions

    Science.gov (United States)

    2004-09-08

    on Interrogation Process (June 22, 2004), available at [http://www.defenselink.mil/releases/2004/ nr20040622-0930.html]. 2 See A. J . BARKER, PRISONERS...U.S. ARMY JUDGE ADVOCATE SCHOOL, LAW OF WAR WORKSHOP DESKBOOK 83 (CDR Brian J . Bill, ed. 2000) [hereinafter “ L O W D E S K B O O K ” ] , a v a i l...or purpose behind the conduct is a prohibited purpose. See Prosecutor v. Kunarac, Kovac and Vukovic , Nos. IT-96-23 and IT-96-23/11, para. 486 (ITCY

  5. Interrogation cradle and insertable containment fixture for detecting birefringent microcrystals in bile

    Science.gov (United States)

    Darrow, Chris; Seger, Tino

    2003-09-30

    A transparent flow channel fluidly communicates a fluid source and a collection reservoir. An interrogating light beam passes through a first polarizer having a first plane of polarization. The flow channel is orthogonal to the light beam. The light beam passes through a fluid sample as it flows through the flow channel, and is then filtered through a second polarizer having a second plane of polarization rotated 90.degree. from the first plane of polarization. An electronic photo-detector is aligned with the light beam, and signals the presence of birefringent microcrystals in the fluid sample by generating voltage pulses. A disposable containment fixture includes the flow channel and the collection reservoir. The fixture is adapted for removable insertion into an interrogation cradle that includes optical and data processing components. The cradle rigidly positions the centerline of the flow channel orthogonal to the light beam.

  6. Wavelength interrogation of fiber Bragg grating sensors based on crossed optical Gaussian filters.

    Science.gov (United States)

    Cheng, Rui; Xia, Li; Zhou, Jiaao; Liu, Deming

    2015-04-15

    Conventional intensity-modulated measurements require to be operated in linear range of filter or interferometric response to ensure a linear detection. Here, we present a wavelength interrogation system for fiber Bragg grating sensors where the linear transition is achieved with crossed Gaussian transmissions. This unique filtering characteristic makes the responses of the two branch detections follow Gaussian functions with the same parameters except for a delay. The substraction of these two delayed Gaussian responses (in dB) ultimately leads to a linear behavior, which is exploited for the sensor wavelength determination. Beside its flexibility and inherently power insensitivity, the proposal also shows a potential of a much wider operational range. Interrogation of a strain-tuned grating was accomplished, with a wide sensitivity tuning range from 2.56 to 8.7 dB/nm achieved.

  7. Evaluation of the neutron self-interrogation approach for assay of plutonium in high materials

    International Nuclear Information System (INIS)

    Russo, P.A.; Menlove, H.O.; Fife, K.W.; West, M.H.

    1987-01-01

    The pyrochemical scrap recovery processes, designed to extract impurities from plutonium metal and compounds, generate a variety of plutonium-laden residues consisting of high (α,n) matrices of varying chemical composition, and often containing grams to tens of grams of americium. For such materials, multiplication corrections based on real neutron coincidence count rate, R, and total neutron count rate, T, measurements cannot be applied because of the large, unknown, and variable (α,n) component in the total neutron emission rate. A study of the prototype self-interrogation assay method is in progress at the Los Alamos plutonium facility. In the self-interrogation approach, the assay signature R(IF)/T is a function of effective fissile plutonium content, where R(IF) is the induced fission component of the measured reals rate, and T is the measured, (α,n)-dominated totals rate. The present study includes a calibration effort using standards consisting of mixtures of PuO 2 and PuF 4 in a salt-strip matrix. The neutron measurements of the standards and the process materials have been performed at the Los Alamos Plutonium Facility. The precision and accuracy of the self-interrogation method applied to pyrochemical residues is examined in this study

  8. Ultraviolet Raman Spectral Signatures in Support of Lisa (Laser Interrogation of Surface Agents)

    National Research Council Canada - National Science Library

    Sedlacek, III, Arthur J; Finfrock, Charles C; Christesen, Steve; Chyba, Tom; Higdon, Scott

    2003-01-01

    ... (Laser Interrogation of Surface Agents). This engineering, testing and evaluation effort uses a novel mini-Raman lidar technique for on-the-move, short-range, non-contact detection and identification of chemical agents on the battlefield...

  9. A new proof-of-principle contraband detection system

    Energy Technology Data Exchange (ETDEWEB)

    Sredniawski, J.J.; Debiak, T.; Kamykowski, E.; Rathke, J. [Northrop Grumman Corp., Bethpage, NY (United States). Advanced Technology and Development Center; Schmor, P.; Altman, A.; Rogers, J.; Boyd, J. [British Columbia Univ., Vancouver, BC (Canada). TRIUMF Facility; Brondo, J. [Scientific Innovations, Inc., East Hampton, NY (United States)

    1995-12-01

    A new concept for a CDS has been developed under a Phase I ARPA funded program; it uses gamma resonance absorption (GRA) to detect certain illegal drugs that may be transported in man-portable containers. A high detection probability for heroin and cocaine is possible with a device that is also searching for explosives. Elemental detection of both N and Cl is utilized, and with tomography, a 3D density image of the elements is generated. Total density image is also developed. These two together may be used with considerable confidence in determining if heroin or cocaine is present in the interrogated containers in a small quantity (1 kg). The CDS employs a high current ({ge}10 mA) DC accelerator that produces a beam of 1.75 or 1.89 MeV protons. These protons impact a target with coatings of {sup 13}C and {sup 34}S. Depending on the coating, the resultant resonant gamma rays are preferentially absorbed in either {sup 14}N or {sup 35}Cl. The resonant gammas come off the target in a conical fan at 80.7{degree} for N and 82{degree} for Cl; a common array of segmented BGO detectors is used over an arc of 53{degree} to provide input to an imaging subsystem. The tomography makes use of rotation and vertical translation of a baggage carousel holding typically 18 average sized bags for batch processing of the contents. The single proton accelerator and target can supply multiple detection stations with the appropriate gammas, a feature that may lead to very high throughput potential approaching 2000 bags/hr. Each detection station can operate somewhat independently from the others. This paper presents the overall requirements, design, operating principles, and characteristics of the CDS proof-of-principle device developed in the Phase I program.

  10. An Evaluation of "Miranda" Rights and Interrogation in Autism Spectrum Disorders

    Science.gov (United States)

    Salseda, Lindsay M.; Dixon, Dennis R.; Fass, Tracy; Miora, Deborah; Leark, Robert A.

    2011-01-01

    The primary deficits present in autism spectrum disorders (ASD) may lead to increased susceptibility to involvement in the criminal justice system. The same deficits may also cause individuals with ASD to be more vulnerable to interrogation techniques and other aspects of the legal system. Due to the increased level of vulnerability as well as…

  11. Peak wavelength interrogation of fiber Bragg grating sensors during impact events

    International Nuclear Information System (INIS)

    Park, Chun; Peters, Kara; Zikry, Mohammed; Haber, Todd; Schultz, Stephen; Selfridge, Richard

    2010-01-01

    In this paper, we embed fiber Bragg grating (FBG) sensors in graphite fiber–epoxy woven composite laminates to detect evolving damage modes. The peak wavelengths of the FBG sensors are interrogated at 625 and 295 kHz, while the laminates are subjected to 11.0 J low-velocity impact events. It is demonstrated that 295 kHz interrogation is sufficient for accurately collecting the dynamic response of the sensors. The FBG sensors embedded at the laminate midplanes successfully reconstructed the global laminate response to impact. The maximum and full width at half-maximum (FWHM) for the relative strain histories demonstrated the same trends as the maximum and FWHM of the contact force histories measured from the impactor. More noise was present in the strain histories obtained from the FBG sensors than the contact force histories, as the embedded FBGs were sensitive to local perturbations in the stress state. The FBG sensors embedded below the midplane of the laminate were closer to the damage regions and measured complex strain histories. In one case, this strain history revealed the presence of delamination

  12. Design of a neutron interrogation cell based on an electron accelerator and performance assessment on 220 liter nuclear waste mock-up drums

    International Nuclear Information System (INIS)

    Sari, A.; Carrel, F.; Laine, F.; Lyoussi, A.

    2013-01-01

    Radiological characterization of nuclear waste drums is an important task for the nuclear industry. The amount of actinides, such as 235 U or 239 Pu, contained in a package can be determined using non-destructive active methods based on the fission process. One of these techniques, known as neutron interrogation, uses a neutron beam to induce fission reactions on the actinides. Optimization of the neutron flux is an important step towards improving this technique. Electron accelerators enable to achieve higher neutron flux intensities than the ones delivered by deuterium-tritium generators traditionally used on neutron interrogation industrial facilities. In this paper, we design a neutron interrogation cell based on an electron accelerator by MCNPX simulation. We carry out photoneutron interrogation measurements on uranium samples placed at the center of 220 liter nuclear waste drums containing different types of matrices. We quantify impact of the matrix on the prompt neutron signal, on the ratio between the prompt and delayed neutron signals, and on the interrogative neutron half-life time. We also show that characteristics of the conversion target of the electron accelerator enable to improve significantly measurement performances. (authors)

  13. Authoritative knowledge, the technological imperative and women's responses to prenatal diagnostic technologies.

    Science.gov (United States)

    McCoyd, Judith L M

    2010-12-01

    Theories about authoritative knowledge (AK) and the technological imperative have received varying levels of interest in anthropological, feminist and science and technology studies. Although the anthropological literature abounds with empirical considerations of authoritative knowledge, few have considered both theories through an empirical, inductive lens. Data extracted from an earlier study of 30 women's responses to termination for fetal anomaly are reanalyzed to consider the women's views of, and responses to, prenatal diagnostic technologies (PNDTs). Findings indicate that a small minority embrace the societal portrayal of technology as univalently positive, while the majority have nuanced and ambivalent responses to the use of PNDTs. Further, the interface of authoritative knowledge and the technological imperative suggests that AK derives not only from medical provider status and technology use, but also from the adequacy and trustworthiness of the information. The issue of timing and uncertainty of the information also are interrogated for their impact on women's lives and what that can illuminate about the theories of AK and the technological imperative.

  14. A Fiber Bragg Grating Interrogation System with Self-Adaption Threshold Peak Detection Algorithm.

    Science.gov (United States)

    Zhang, Weifang; Li, Yingwu; Jin, Bo; Ren, Feifei; Wang, Hongxun; Dai, Wei

    2018-04-08

    A Fiber Bragg Grating (FBG) interrogation system with a self-adaption threshold peak detection algorithm is proposed and experimentally demonstrated in this study. This system is composed of a field programmable gate array (FPGA) and advanced RISC machine (ARM) platform, tunable Fabry-Perot (F-P) filter and optical switch. To improve system resolution, the F-P filter was employed. As this filter is non-linear, this causes the shifting of central wavelengths with the deviation compensated by the parts of the circuit. Time-division multiplexing (TDM) of FBG sensors is achieved by an optical switch, with the system able to realize the combination of 256 FBG sensors. The wavelength scanning speed of 800 Hz can be achieved by a FPGA+ARM platform. In addition, a peak detection algorithm based on a self-adaption threshold is designed and the peak recognition rate is 100%. Experiments with different temperatures were conducted to demonstrate the effectiveness of the system. Four FBG sensors were examined in the thermal chamber without stress. When the temperature changed from 0 °C to 100 °C, the degree of linearity between central wavelengths and temperature was about 0.999 with the temperature sensitivity being 10 pm/°C. The static interrogation precision was able to reach 0.5 pm. Through the comparison of different peak detection algorithms and interrogation approaches, the system was verified to have an optimum comprehensive performance in terms of precision, capacity and speed.

  15. Fast Interrogation of Fiber Bragg Gratings with Electro-Optical Dual Optical Frequency Combs.

    Science.gov (United States)

    Posada-Roman, Julio E; Garcia-Souto, Jose A; Poiana, Dragos A; Acedo, Pablo

    2016-11-26

    Optical frequency combs (OFC) generated by electro-optic modulation of continuous-wave lasers provide broadband coherent sources with high power per line and independent control of line spacing and the number of lines. In addition to their application in spectroscopy, they offer flexible and optimized sources for the interrogation of other sensors based on wavelength change or wavelength filtering, such as fiber Bragg grating (FBG) sensors. In this paper, a dual-OFC FBG interrogation system based on a single laser and two optical-phase modulators is presented. This architecture allows for the configuration of multimode optical source parameters such as the number of modes and their position within the reflected spectrum of the FBG. A direct read-out is obtained by mapping the optical spectrum onto the radio-frequency spectrum output of the dual-comb. This interrogation scheme is proposed for measuring fast phenomena such as vibrations and ultrasounds. Results are presented for dual-comb operation under optimized control. The optical modes are mapped onto detectable tones that are multiples of 0.5 MHz around a center radiofrequency tone (40 MHz). Measurements of ultrasounds (40 kHz and 120 kHz) are demonstrated with this sensing system. Ultrasounds induce dynamic strain onto the fiber, which generates changes in the reflected Bragg wavelength and, hence, modulates the amplitude of the OFC modes within the reflected spectrum. The amplitude modulation of two counterphase tones is detected to obtain a differential measurement proportional to the ultrasound signal.

  16. Fast Interrogation of Fiber Bragg Gratings with Electro-Optical Dual Optical Frequency Combs

    Directory of Open Access Journals (Sweden)

    Julio E. Posada-Roman

    2016-11-01

    Full Text Available Optical frequency combs (OFC generated by electro-optic modulation of continuous-wave lasers provide broadband coherent sources with high power per line and independent control of line spacing and the number of lines. In addition to their application in spectroscopy, they offer flexible and optimized sources for the interrogation of other sensors based on wavelength change or wavelength filtering, such as fiber Bragg grating (FBG sensors. In this paper, a dual-OFC FBG interrogation system based on a single laser and two optical-phase modulators is presented. This architecture allows for the configuration of multimode optical source parameters such as the number of modes and their position within the reflected spectrum of the FBG. A direct read-out is obtained by mapping the optical spectrum onto the radio-frequency spectrum output of the dual-comb. This interrogation scheme is proposed for measuring fast phenomena such as vibrations and ultrasounds. Results are presented for dual-comb operation under optimized control. The optical modes are mapped onto detectable tones that are multiples of 0.5 MHz around a center radiofrequency tone (40 MHz. Measurements of ultrasounds (40 kHz and 120 kHz are demonstrated with this sensing system. Ultrasounds induce dynamic strain onto the fiber, which generates changes in the reflected Bragg wavelength and, hence, modulates the amplitude of the OFC modes within the reflected spectrum. The amplitude modulation of two counterphase tones is detected to obtain a differential measurement proportional to the ultrasound signal.

  17. A Fiber Bragg Grating Interrogation System with Self-Adaption Threshold Peak Detection Algorithm

    Directory of Open Access Journals (Sweden)

    Weifang Zhang

    2018-04-01

    Full Text Available A Fiber Bragg Grating (FBG interrogation system with a self-adaption threshold peak detection algorithm is proposed and experimentally demonstrated in this study. This system is composed of a field programmable gate array (FPGA and advanced RISC machine (ARM platform, tunable Fabry–Perot (F–P filter and optical switch. To improve system resolution, the F–P filter was employed. As this filter is non-linear, this causes the shifting of central wavelengths with the deviation compensated by the parts of the circuit. Time-division multiplexing (TDM of FBG sensors is achieved by an optical switch, with the system able to realize the combination of 256 FBG sensors. The wavelength scanning speed of 800 Hz can be achieved by a FPGA+ARM platform. In addition, a peak detection algorithm based on a self-adaption threshold is designed and the peak recognition rate is 100%. Experiments with different temperatures were conducted to demonstrate the effectiveness of the system. Four FBG sensors were examined in the thermal chamber without stress. When the temperature changed from 0 °C to 100 °C, the degree of linearity between central wavelengths and temperature was about 0.999 with the temperature sensitivity being 10 pm/°C. The static interrogation precision was able to reach 0.5 pm. Through the comparison of different peak detection algorithms and interrogation approaches, the system was verified to have an optimum comprehensive performance in terms of precision, capacity and speed.

  18. Causal Interrogation of Neuronal Networks and Behavior through Virally Transduced Ivermectin Receptors.

    Science.gov (United States)

    Obenhaus, Horst A; Rozov, Andrei; Bertocchi, Ilaria; Tang, Wannan; Kirsch, Joachim; Betz, Heinrich; Sprengel, Rolf

    2016-01-01

    The causal interrogation of neuronal networks involved in specific behaviors requires the spatially and temporally controlled modulation of neuronal activity. For long-term manipulation of neuronal activity, chemogenetic tools provide a reasonable alternative to short-term optogenetic approaches. Here we show that virus mediated gene transfer of the ivermectin (IVM) activated glycine receptor mutant GlyRα1 (AG) can be used for the selective and reversible silencing of specific neuronal networks in mice. In the striatum, dorsal hippocampus, and olfactory bulb, GlyRα1 (AG) promoted IVM dependent effects in representative behavioral assays. Moreover, GlyRα1 (AG) mediated silencing had a strong and reversible impact on neuronal ensemble activity and c-Fos activation in the olfactory bulb. Together our results demonstrate that long-term, reversible and re-inducible neuronal silencing via GlyRα1 (AG) is a promising tool for the interrogation of network mechanisms underlying the control of behavior and memory formation.

  19. Syncope During Competitive Events: Interrogating Heart Rate Monitor Watches May Be Useful!

    Science.gov (United States)

    Thabouillot, Oscar; Bostanci, Kevin; Bouvier, Francois; Dumitrescu, Nicolae; Stéfuriac, Maria; Paule, Philippe; Roche, Nicolas-Charles

    2017-12-01

    This is a case report of a 45-year-old man who reported complete amnesia during the very first kilometer of a 10-km run. He was wearing a heart rate monitor (HRM). The interrogation of his HRM watch showed 200 bpm tachycardia beginning in the first kilometer and increasing up to 220 bpm during the last kilometer. The patient was asked to wear a Holter-monitor (Holter Research Laboratory; Helena, Montana USA) electrocardiogram (ECG) while practicing a training session. This examination allowed for the diagnosis of an adrenergic paroxysmal atrial fibrillation (AF) with an impressive auriculo-ventricular conduction over 260 bpm. This case highlights that non-medical devices, such as connected watches, can be helpful to diagnose arrhythmias. Thabouillot O , Bostanci K , Bouvier F , Dumitrescu N , Stéfuriac M , Paule P , Roche NC . Syncope during competitive events: interrogating heart rate monitor watches may be useful! Prehosp Disaster Med. 2017;32(6):691-693.

  20. PRESTO-Tango as an open-source resource for interrogation of the druggable human GPCRome.

    Science.gov (United States)

    Kroeze, Wesley K; Sassano, Maria F; Huang, Xi-Ping; Lansu, Katherine; McCorvy, John D; Giguère, Patrick M; Sciaky, Noah; Roth, Bryan L

    2015-05-01

    G protein-coupled receptors (GPCRs) are essential mediators of cellular signaling and are important targets of drug action. Of the approximately 350 nonolfactory human GPCRs, more than 100 are still considered to be 'orphans' because their endogenous ligands remain unknown. Here, we describe a unique open-source resource that allows interrogation of the druggable human GPCRome via a G protein-independent β-arrestin-recruitment assay. We validate this unique platform at more than 120 nonorphan human GPCR targets, demonstrate its utility for discovering new ligands for orphan human GPCRs and describe a method (parallel receptorome expression and screening via transcriptional output, with transcriptional activation following arrestin translocation (PRESTO-Tango)) for the simultaneous and parallel interrogation of the entire human nonolfactory GPCRome.

  1. Coaxial Mono-Energetic Gamma Generator for Active Interrogation

    International Nuclear Information System (INIS)

    Ludewigt, Bernhard A.; Antolak, A.J.; Henestroza, E.; Leitner, M.; Leung, K.-N.; Waldron, W.; Wilde, S.; Kwan, J.W.

    2008-01-01

    Compact mono-energetic photon sources are sought for active interrogation systems to detect shielded special nuclear materials in, for example, cargo containers, trucks and other vehicles. A prototype gamma interrogation source has been designed and built that utilizes the 11B(p,gamma)12C reaction to produce 12 MeV gamma-rays which are near the peak of the photofission cross section. In particular, the 11B(p,gamma)12C resonance at 163 kV allows the production of gammas at low proton acceleration voltages, thus keeping the design of a gamma generator comparatively small and simple. A coaxial design has been adopted with a toroidal-shaped plasma chamber surrounding a cylindrical gamma production target. The plasma discharge is driven by a 2 MHz rf-power supply (capable up to 50 kW) using a circular rf-antenna. Permanent magnets embedded in the walls of the plasma chamber generate a multi-cusp field that confines the plasma and allows higher plasma densities and lower gas pressures. About 100 proton beamlets are extracted through a slotted plasma electrode towards the target at the center of the device that is at a negative 180 kV. The target consists of LaB6 tiles that are brazed to a water-cooled cylindrical structure. The generator is designed to operate at 500 Hz with 20 mu s long pulses, and a 1percent duty factor by pulsing the ion source rf-power. A first-generation coaxial gamma source has been built for low duty factor experiments and testing.

  2. Novel birefringence interrogation for Sagnac loop interferometer sensor with unlimited linear measurement range.

    Science.gov (United States)

    He, Haijun; Shao, Liyang; Qian, Heng; Zhang, Xinpu; Liang, Jiawei; Luo, Bin; Pan, Wei; Yan, Lianshan

    2017-03-20

    A novel demodulation method for Sagnac loop interferometer based sensor has been proposed and demonstrated, by unwrapping the phase changes with birefringence interrogation. A temperature sensor based on Sagnac loop interferometer has been used to verify the feasibility of the proposed method. Several tests with 40 °C temperature range have been accomplished with a great linearity of 0.9996 in full range. The proposed scheme is universal for all Sagnac loop interferometer based sensors and it has unlimited linear measurable range which overwhelming the conventional demodulation method with peak/dip tracing. Furthermore, the influence of the wavelength sampling interval and wavelength span on the demodulation error has been discussed in this work. The proposed interrogation method has a great significance for Sagnac loop interferometer sensor and it might greatly enhance the availability of this type of sensors in practical application.

  3. Photon interrogation annual report for FY-1980

    International Nuclear Information System (INIS)

    Nieschmidt, E.B.; Tsang, F.Y.; Lawrence, R.S.; Vegors, S.H. Jr.

    1980-12-01

    The Photon Interrogation Technique is being developed for the assay of transuranic materials. A description of source and detector geometry, die-away times and photon flux measurements is given. Considerable effort during FY-1980 was devoted to collimator construction and shielding materials and configurations. Boric acid was found to be a very efficient shielding material for this application. Descriptions and results of these efforts are presented. Results of photon flux determinations, system response to source position and their effects on accuracy are discussed. Changes in the detector system produced a considerable efficiency increase and instrumentation changes brought improved performance. The instrument system with additions can obtain neutron spectral information. A schedule for further development of the system is presented

  4. Chemical mutagens, transposons, and transgenes to interrogate gene function in Drosophila melanogaster.

    Science.gov (United States)

    Venken, Koen J T; Bellen, Hugo J

    2014-06-15

    The study of genetics, genes, and chromosomal inheritance was initiated by Thomas Morgan in 1910, when the first visible mutations were identified in fruit flies. The field expanded upon the work initiated by Herman Muller in 1926 when he used X-rays to develop the first balancer chromosomes. Today, balancers are still invaluable to maintain mutations and transgenes but the arsenal of tools has expanded vastly and numerous new methods have been developed, many relying on the availability of the genome sequence and transposable elements. Forward genetic screens based on chemical mutagenesis or transposable elements have resulted in the unbiased identification of many novel players involved in processes probed by specific phenotypic assays. Reverse genetic approaches have relied on the availability of a carefully selected set of transposon insertions spread throughout the genome to allow the manipulation of the region in the vicinity of each insertion. Lastly, the ability to transform Drosophila with single copy transgenes using transposons or site-specific integration using the ΦC31 integrase has allowed numerous manipulations, including the ability to create and integrate genomic rescue constructs, generate duplications, RNAi knock-out technology, binary expression systems like the GAL4/UAS system as well as other methods. Here, we will discuss the most useful methodologies to interrogate the fruit fly genome in vivo focusing on chemical mutagenesis, transposons and transgenes. Genome engineering approaches based on nucleases and RNAi technology are discussed in following chapters. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Neutron interrogation system using high gamma ray signature to detect contraband special nuclear materials in cargo

    Science.gov (United States)

    Slaughter, Dennis R [Oakland, CA; Pohl, Bertram A [Berkeley, CA; Dougan, Arden D [San Ramon, CA; Bernstein, Adam [Palo Alto, CA; Prussin, Stanley G [Kensington, CA; Norman, Eric B [Oakland, CA

    2008-04-15

    A system for inspecting cargo for the presence of special nuclear material. The cargo is irradiated with neutrons. The neutrons produce fission products in the special nuclear material which generate gamma rays. The gamma rays are detecting indicating the presence of the special nuclear material.

  6. Technician-Supported Remote Interrogation of CIEDs: Initial Use in US Emergency Departments and Perioperative Areas.

    Science.gov (United States)

    Ahmed, Imdad; Patel, Amisha S; Balgaard, Timothy J; Rosenfeld, Lynda E

    2016-03-01

    Interrogation/interpretation of cardiac implantable electronic devices (CIEDs) is frequently required in the emergency department (ED) or perioperative areas (OR) where resources to do this are often not available. CareLink Express (CLE; Medtronic, plc, Mounds View, MN, USA) is a technician-supported real-time remote interrogation system for Medtronic CIEDs. Using data from 136 US locations, this retrospective study was designed to assess CLE efficiency compared to traditional device management, and examine its findings. All 7,044 US CLE transmissions from the ED and OR (January 2012-October 2014) were compared to 217 traditional requests where CIED interrogations/interpretations were performed by calling industry representatives to these sites. CLE reduced the time to device interrogation/interpretation by 78%: 100 ± 140-22 ± 14 minutes, P < 0.0001, improving response time and consistency; ED: 82 ± 103-23 ± 18 minutes, P, ≤ 0.01; OR: 127 ± 181-17 ± 10 minutes, P < 0.0001. Actionable events (AE) (arrhythmia, device/lead abnormalities) were infrequent: 9.1% overall (ED: 9.9%; OR: 4.1%). Only 6.5% of patients with syncope/presyncope and 13.6% with a perceived shock had AE. AEs were more common in those with suspected device problems (30.4%) or audible alerts (52.6%). They were more likely in patients not enrolled in long-term remote monitoring (23.9% vs 8.2%, P < 0.0001) and in those with older CIED systems (7.4% in year 1 vs 31.0% after 10 years). The many patients with CIEDs, and the ability to quickly identify the minority with high-risk AE from the no/low-risk majority, strongly support CLE use in the ED and OR, sites which are expensive and prioritize efficiency. © 2015 Wiley Periodicals, Inc.

  7. Interrogation of fibre Bragg gratings through a fibre optic rotary joint on a geotechnical centrifuge

    Science.gov (United States)

    Correia, Ricardo; James, Stephen W.; Marshall, Alec; Heron, Charles; Korposh, Sergiy

    2016-05-01

    The monitoring of an array of fibre Bragg gratings (FBGs) strain sensors was performed through a single channel, single mode fibre optic rotary joint (FORJ) mounted on a geotechnical centrifuge. The array of three FBGs was attached to an aluminum plate that was anchored at the ends and placed on the model platform of the centrifuge. Acceleration forces of up to 50g were applied and the reflection signal of the monitored FBGs recorded dynamically using a 2.5kHz FBG interrogator placed outside the centrifuge. The use of a FORJ allowed the monitoring of the FBGs without submitting the FBG interrogator to the high g-forces experienced in the centrifuge.

  8. Interrogating adhesion using fiber Bragg grating sensing technology

    Science.gov (United States)

    Rasberry, Roger D.; Rohr, Garth D.; Miller, William K.; Udd, Eric; Blach, Noah T.; Davis, Ryan A.; Olson, Walter R.; Calkins, David; Roach, Allen R.; Walsh, David S.; McElhanon, James R.

    2015-05-01

    The assurance of the integrity of adhesive bonding at substrate interfaces is paramount to the longevity and sustainability of encapsulated components. Unfortunately, it is often difficult to non-destructively evaluate these materials to determine the adequacy of bonding after manufacturing and then later in service. A particularly difficult problem in this regard is the reliable detection/monitoring of regions of weak bonding that may result from poor adhesion or poor cohesive strength, or degradation in service. One promising and perhaps less explored avenue we have recently begun to investigate for this purpose centers on the use of (chirped) fiber Bragg grating sensing technology. In this scenario, a grating is patterned into a fiber optic such that a (broadband) spectral reflectance is observed. The sensor is highly sensitive to local and uniform changes across the length of the grating. Initial efforts to evaluate this approach for measuring adhesive bonding defects at substrate interfaces are discussed. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  9. Nanoscale Plasmonic V-Groove Waveguides for the Interrogation of Single Fluorescent Bacterial Cells

    DEFF Research Database (Denmark)

    Lotan, Oren; Bar-David, Jonathan; Smith, Cameron

    2017-01-01

    We experimentally demonstrate the interrogation of an individual Escherichia coli cell using a nanoscale plasmonic V-groove waveguide. Several different configurations were studied. The first involved the excitation of the cell in a liquid environment because it flows on top of the waveguide...

  10. The Lawyer in the Dutch Interrogation Room: Influence on Police and Suspect

    NARCIS (Netherlands)

    W-J. Verhoeven (Willem-Jan); L. Stevens (Lonneke)

    2012-01-01

    textabstractIn many European countries, providing a suspect in custody with legal aid before the first police interrogation is a heavily debated issue. In this paper, we report on an exploratory study on the use of coercion by the police and the use of the right to silence by suspects in 70 Dutch

  11. Monitoring system including an electronic sensor platform and an interrogation transceiver

    Science.gov (United States)

    Kinzel, Robert L.; Sheets, Larry R.

    2003-09-23

    A wireless monitoring system suitable for a wide range of remote data collection applications. The system includes at least one Electronic Sensor Platform (ESP), an Interrogator Transceiver (IT) and a general purpose host computer. The ESP functions as a remote data collector from a number of digital and analog sensors located therein. The host computer provides for data logging, testing, demonstration, installation checkout, and troubleshooting of the system. The IT transmits signals from one or more ESP's to the host computer to the ESP's. The IT host computer may be powered by a common power supply, and each ESP is individually powered by a battery. This monitoring system has an extremely low power consumption which allows remote operation of the ESP for long periods; provides authenticated message traffic over a wireless network; utilizes state-of-health and tamper sensors to ensure that the ESP is secure and undamaged; has robust housing of the ESP suitable for use in radiation environments; and is low in cost. With one base station (host computer and interrogator transceiver), multiple ESP's may be controlled at a single monitoring site.

  12. Thermal neutron imaging in an active interrogation environment

    International Nuclear Information System (INIS)

    Vanier, P.E.; Forman, L.; Norman, D.R.

    2009-01-01

    We have developed a thermal-neutron coded-aperture imager that reveals the locations of hydrogenous materials from which thermal neutrons are being emitted. This imaging detector can be combined with an accelerator to form an active interrogation system in which fast neutrons are produced in a heavy metal target by means of excitation by high energy photons. The photo-induced neutrons can be either prompt or delayed, depending on whether neutronemitting fission products are generated. Provided that there are hydrogenous materials close to the target, some of the photo-induced neutrons slow down and emerge from the surface at thermal energies. These neutrons can be used to create images that show the location and shape of the thermalizing materials. Analysis of the temporal response of the neutron flux provides information about delayed neutrons from induced fission if there are fissionable materials in the target. The combination of imaging and time-of-flight discrimination helps to improve the signal-to-background ratio. It is also possible to interrogate the target with neutrons, for example using a D-T generator. In this case, an image can be obtained from hydrogenous material in a target without the presence of heavy metal. In addition, if fissionable material is present in the target, probing with fast neutrons can stimulate delayed neutrons from fission, and the imager can detect and locate the object of interest, using appropriate time gating. Operation of this sensitive detection equipment in the vicinity of an accelerator presents a number of challenges, because the accelerator emits electromagnetic interference as well as stray ionizing radiation, which can mask the signals of interest.

  13. RFID explained a primer on radio frequency identification technologies

    CERN Document Server

    Want, Roy

    2006-01-01

    This lecture provides an introduction to Radio Frequency Identification (RFID), a technology enabling automatic identification of objects at a distance without requiring line-of-sight. Electronic tagging can be divided into technologies that have a power source (active tags), and those that are powered by the tag interrogation signal (passive tags); the focus here is on passive tags. An overview of the principles of the technology divides passive tags into devices that use either near field or far field coupling to communicate with a tag reader. The strengths and weaknesses of the approaches a

  14. Field Prototype of the ENEA Neutron Active Interrogation Device for the Detection of Dirty Bombs

    Directory of Open Access Journals (Sweden)

    Nadia Cherubini

    2016-10-01

    Full Text Available The Italian National Agency for New Technologies, Energy, and Sustainable Economic Development (ENEA Neutron Active Interrogation (NAI device is a tool designed to improve CBRNE defense. It is designed to uncover radioactive and nuclear threats including those in the form of Improvised Explosive Devices (IEDs, the so-called “dirty bombs”. The NAI device, at its current development stage, allows to detect 6 g of 235U hidden in a package. It is easily transportable, light in weight, and with a real-time response. Its working principle is based on two stages: (1 an “active” stage in which neutrons are emitted by a neutron generator to interact with the item under inspection, and (2 a “passive” stage in which secondary neutrons are detected originating a signal that, once processed, allows recognition of the offence. In particular, a clear indication of the potential threat is obtained by a dedicated software based on the Differential Die-Away Time Analysis method.

  15. Time-dependent delayed signatures from energetic photon interrogations

    International Nuclear Information System (INIS)

    Norman, Daren R.; Jones, James L.; Blackburn, Brandon W.; Haskell, Kevin J.; Johnson, James T.; Watson, Scott M.; Hunt, Alan W.; Spaulding, Randy; Harmon, Frank

    2007-01-01

    Pulsed photonuclear interrogation environments generated by 8-24 MeV electron linac are rich with time-dependent, material-specific, radiation signatures. Nitrogen-based explosives and nuclear materials can be detected by exploiting these signatures in different delayed-time regions. Numerical and experimental results presented in this paper show the unique time and energy dependence of these signatures. It is shown that appropriate delayed-time windows are essential to acquire material-specific signatures in pulsed photonuclear assessment environments. These developments demonstrate that pulsed, high-energy, photon-inspection environments can be exploited for time-dependent, material-specific signatures through the proper operation of specialized detectors and detection methods

  16. Interrogative suggestibility: its relationship with assertiveness, social-evaluative anxiety, state anxiety and method of coping.

    Science.gov (United States)

    Gudjonsson, G H

    1988-05-01

    This paper attempts to investigate empirically in 30 subjects some of the theoretical components related to individual differences that are thought by Gudjonsson & Clark (1986) to mediate interrogative suggestibility as measured by the Gudjonsson Suggestibility Scale (GSS; Gudjonsson, 1984a). The variables studied were: assertiveness, social-evaluative anxiety, state anxiety and the coping methods subjects are able to generate and implement during interrogation. Low assertiveness and high evaluative anxiety were found to correlate moderately with suggestibility, but no significant correlations emerged for 'social avoidance and distress'. State anxiety correlated significantly with suggestibility, particularly after negative feedback had been administered. Coping methods (active-cognitive/behavioural vs. avoidance) significantly predicted suggestibility scores. The findings give strong support to the theoretical model of Gudjonsson & Clark.

  17. The SVM Method for Fissile Mass Estimation through Passive Neutron Interrogation: Advances and Developments

    International Nuclear Information System (INIS)

    Dubi, C.; Shvili, Israel I.

    2014-01-01

    Fissile mass estimation through passive neutron interrogation is now one of the main techniques for NDT of fissile mass estimation, due to the relative transparency of neutron radiation to structural materials- making it extremely effective in poorly characterized or dirty samples . Passive neutron interrogation relies on the fact that the number of neutrons emitted (per time unit) due to spontaneous fissions from the sample is proportional to the mass of the detected sample. However, since the measurement is effected by additional neutron sources- mainly (D±n) reactions and induced fission chain in the tested sample, a naive estimation, assuming a linear correspondence between the mass of the detected sample and the average number of detections, is bound to give an over estimation of the mass. Since most passive interrogation facilities are based on 3He detectors, the origin of the neutron cannot be determined by analyzing the energy spectrum (as all neutrons arrive at the detector in more or less the same energy), and a mathematical 'filter' is used to evaluate the noise to source ratio in the detection signal. The basic idea behind the mathematical filter is to utilize the fact that the different neutron sources have different statistical attributes- in particular, both the source event rate and the distribution of the number of neutrons released in each event differs between the different sources. There for, by studying the higher moments of the neutron population, new information about the source to noise ration may be obtained

  18. Duplex Interrogation by a Direct DNA Repair Protein in Search of Base Damage

    Science.gov (United States)

    Yi, Chengqi; Chen, Baoen; Qi, Bo; Zhang, Wen; Jia, Guifang; Zhang, Liang; Li, Charles J.; Dinner, Aaron R.; Yang, Cai-Guang; He, Chuan

    2012-01-01

    ALKBH2 is a direct DNA repair dioxygenase guarding mammalian genome against N1-methyladenine, N3-methylcytosine, and 1,N6-ethenoadenine damage. A prerequisite for repair is to identify these lesions in the genome. Here we present crystal structures of ALKBH2 bound to different duplex DNAs. Together with computational and biochemical analyses, our results suggest that DNA interrogation by ALKBH2 displays two novel features: i) ALKBH2 probes base-pair stability and detects base pairs with reduced stability; ii) ALKBH2 does not have nor need a “damage-checking site”, which is critical for preventing spurious base-cleavage for several glycosylases. The demethylation mechanism of ALKBH2 insures that only cognate lesions are oxidized and reversed to normal bases, and that a flipped, non-substrate base remains intact in the active site. Overall, the combination of duplex interrogation and oxidation chemistry allows ALKBH2 to detect and process diverse lesions efficiently and correctly. PMID:22659876

  19. A quasi-distributed temperature sensor interrogated by a wavelength-sensitive optical time-domain reflectometer

    International Nuclear Information System (INIS)

    Crunelle, C; Wuilpart, M; Caucheteur, C; Mégret, P

    2009-01-01

    In this note, we present a quasi-distributed temperature monitoring system based on the concatenation of identical low-reflective fiber Bragg gratings (FBGs) and interrogated by means of an optical time-domain reflectometer (OTDR). An original wavelength-sensitive system placed before the OTDR detector is used to analyze the reflected signal. This system allows the height of the FBG reflection peaks in the OTDR trace to depend on their resonance wavelength, and therefore to the local temperature. In addition, a simple but original reference method is proposed. The configuration of the whole interrogating device is kept very basic, as a standard OTDR and some passive components are used. The cost of the overall system is therefore very limited. In this note, the wavelength-sensitive system is studied in details, as well as the reference method. Experimental results are reported. (technical design note)

  20. A programme for Euratom safeguards inspectors, used in the assay of high enriched (H.E.U.) and low enriched (L.E.U.) uranium fuel materials by active neutron interrogation

    International Nuclear Information System (INIS)

    Vocino, V.; Farese, N.; Maucq, T.; Nebuloni, M.

    1991-01-01

    The programme AECC (Active Euratom Coincidence Counters) has been developed at the Joint Research Center, Ispra by the Euratom Safeguards Directorate, Luxembourg and the Safety Technology Institute, Ispra for the acquisition, evaluation, management and storage of measurement data originating from active neutron interrogation of HEU and LEU fuel materials. The software accommodates the implementation of the NDA (Non Destructive Assay) procedures for the Active Well Coincidence Counters and Active Neutron Coincidence Counters deployed by the Euratom Safeguards Directorate, Luxembourg

  1. French Interrogative Structures: A New Pedagogical Norm for the 21st-Century Classroom

    Science.gov (United States)

    Antes, Theresa A.

    2016-01-01

    This study investigated interrogative structures most frequently used by native speakers of French, in an attempt to reconcile differences between language forms taught in the French as a foreign language classroom and those that are encountered in authentic input. Radio, television, and magazine interviews provided multiple examples of…

  2. Interrogative Suggestibility among Adolescent Boys and Its Relationship with Intelligence, Memory, and Cognitive Set.

    Science.gov (United States)

    Singh, Krishna K.; Gudjonsson, Gisli H.

    1992-01-01

    Investigated hypotheses generated by Gudjonsson and Clark model of interrogative suggestibility. Adolescent boys (n=40) completed Gudjonsson Suggestibility Scale and measures of intellectual skills, memory, field-dependence, hostility, and attitudes toward persons in authority. Suggestibility correlated negatively with intelligence quotient and…

  3. Interrogated with Intellectual Disabilities: The Risks of False Confession.

    Science.gov (United States)

    Schatz, Samson J

    2018-02-01

    False confessions happen. At least 245 people have been exonerated from convictions in cases featuring confessions that were simply not true. Confessions offer a narrative that allows law enforcement, and society in general, to neatly resolve cases with apparent clarity and closure. And yet the pressures officers place on suspects to provide that closure weigh disproportionately on the vulnerable, including individuals with intellectual disabilities. These individuals are disadvantaged at every step of the custodial interrogation, and they face heightened risks of falsely confessing. Moreover, the principal judicial safeguards against false confessions--assessing a suspect's Miranda waiver and determining whether a confession was voluntarily given within the bounds of the Fourteenth Amendment’s Due Process Clause--provide little protection for the innocent with intellectual disabilities. Few pieces of scholarship focus specifically on the heightened risks faced by individuals with intellectual disabilities throughout the process of police interrogation. This Note describes the various ways these individuals are disadvantaged. And it offers an additional data point illustrating the vulnerability of people with intellectual disabilities. This Note analyzes the 245 individuals (as of June 2, 2017) on the National Registry of Exonerations who have falsely confessed. Over one-quarter of them display indicia of intellectual disability. This percentage dwarfs the prevalence of people with intellectual disabilities in the general population and even exceeds most estimates of the proportion of the prison population suffering from intellectual disabilities. This Note concludes with several policy and doctrinal suggestions to better protect individuals with intellectual disabilities from the risks of false confession.

  4. Mechanism of duplex DNA destabilization by RNA-guided Cas9 nuclease during target interrogation.

    Science.gov (United States)

    Mekler, Vladimir; Minakhin, Leonid; Severinov, Konstantin

    2017-05-23

    The prokaryotic clustered regularly interspaced short palindromic repeats (CRISPR)-associated 9 (Cas9) endonuclease cleaves double-stranded DNA sequences specified by guide RNA molecules and flanked by a protospacer adjacent motif (PAM) and is widely used for genome editing in various organisms. The RNA-programmed Cas9 locates the target site by scanning genomic DNA. We sought to elucidate the mechanism of initial DNA interrogation steps that precede the pairing of target DNA with guide RNA. Using fluorometric and biochemical assays, we studied Cas9/guide RNA complexes with model DNA substrates that mimicked early intermediates on the pathway to the final Cas9/guide RNA-DNA complex. The results show that Cas9/guide RNA binding to PAM favors separation of a few PAM-proximal protospacer base pairs allowing initial target interrogation by guide RNA. The duplex destabilization is mediated, in part, by Cas9/guide RNA affinity for unpaired segments of nontarget strand DNA close to PAM. Furthermore, our data indicate that the entry of double-stranded DNA beyond a short threshold distance from PAM into the Cas9/single-guide RNA (sgRNA) interior is hindered. We suggest that the interactions unfavorable for duplex DNA binding promote DNA bending in the PAM-proximal region during early steps of Cas9/guide RNA-DNA complex formation, thus additionally destabilizing the protospacer duplex. The mechanism that emerges from our analysis explains how the Cas9/sgRNA complex is able to locate the correct target sequence efficiently while interrogating numerous nontarget sequences associated with correct PAMs.

  5. Coherent pulse interrogation system for fiber Bragg grating sensing of strain and pressure in dynamic extremes of materials.

    Science.gov (United States)

    Rodriguez, George; Jaime, Marcelo; Balakirev, Fedor; Mielke, Chuck H; Azad, Abul; Marshall, Bruce; La Lone, Brandon M; Henson, Bryan; Smilowitz, Laura

    2015-06-01

    A 100 MHz fiber Bragg grating (FBG) interrogation system is described and applied to strain and pressure sensing. The approach relies on coherent pulse illumination of the FBG sensor with a broadband short pulse from a femtosecond modelocked erbium fiber laser. After interrogation of the FBG sensor, a long multi-kilometer run of single mode fiber is used for chromatic dispersion to temporally stretch the spectral components of the reflected pulse from the FBG sensor. Dynamic strain or pressure induced spectral shifts in the FBG sensor are detected as a pulsed time domain waveform shift after encoding by the chromatic dispersive line. Signals are recorded using a single 35 GHz photodetector and a 50 G Samples per second, 25 GHz bandwidth, digitizing oscilloscope. Application of this approach to high-speed strain sensing in magnetic materials in pulsed magnetic fields to ~150 T is demonstrated. The FBG wavelength shifts are used to study magnetic field driven magnetostriction effects in LaCoO3. A sub-microsecond temporal shift in the FBG sensor wavelength attached to the sample under first order phase change appears as a fractional length change (strain: ΔL/L-4) in the material. A second application used FBG sensing of pressure dynamics to nearly 2 GPa in the thermal ignition of the high explosive PBX-9501 is also demonstrated. Both applications demonstrate the use of this FBG interrogation system in dynamical extreme conditions that would otherwise not be possible using traditional FBG interrogation approaches that are deemed too slow to resolve such events.

  6. Reading Resistance: The Record of Tsunesaburo Makiguchi's Interrogation by Wartime Japan's "Thought Police"

    Science.gov (United States)

    Ito, Takao

    2009-01-01

    This article examines the record of Tsunesaburo Makiguchi's interrogation as a thought criminal following his arrest in July, 1943. By comparing and contrasting his responses and statements against the official government positions, I hope to clarify the nature of his critique of the wartime fascist regime. Makiguchi himself was an educator, and…

  7. Neutron-based portable drug probe

    International Nuclear Information System (INIS)

    Womble, P. C.; Vourvopoulos, G.; Ball Howard, J.; Paschal, J.

    1999-01-01

    Based on previous measurements, a probe prototype for contraband detection utilizing the neutron technique of Pulsed Fast-Thermal Neutron Analysis (PFTNA) is being constructed. The prototype weighs less than 45 kg and is composed of a probe (5 cm diameter), a power pack and a data acquisition and display system. The probe is designed to be inserted in confined spaces such as the boiler of a ship or a tanker truck filled with liquid. The probe provides information on a) the elemental content, and b) the density variations of the interrogated object. By measuring elemental content, the probe can differentiate between innocuous materials and drugs. Density variations can be found through fast neutron transmission. In all cases, hidden drugs are identified through the measurement of the elemental content of the object, and the comparison of expected and measured elemental ratios

  8. Digitally controlled chirped pulse laser for sub-terahertz-range fiber structure interrogation.

    Science.gov (United States)

    Chen, Zhen; Hefferman, Gerald; Wei, Tao

    2017-03-01

    This Letter reports a sweep velocity-locked laser pulse generator controlled using a digital phase-locked loop (DPLL) circuit. This design is used for the interrogation of sub-terahertz-range fiber structures for sensing applications that require real-time data collection with millimeter-level spatial resolution. A distributed feedback laser was employed to generate chirped laser pulses via injection current modulation. A DPLL circuit was developed to lock the optical frequency sweep velocity. A high-quality linearly chirped laser pulse with a frequency excursion of 117.69 GHz at an optical communication band was demonstrated. The system was further adopted to interrogate a continuously distributed sub-terahertz-range fiber structure (sub-THz-fs) for sensing applications. A strain test was conducted in which the sub-THz-fs showed a linear response to longitudinal strain change with predicted sensitivity. Additionally, temperature testing was conducted in which a heat source was used to generate a temperature distribution along the fiber structure to demonstrate its distributed sensing capability. A Gaussian temperature profile was measured using the described system and tracked in real time, as the heat source was moved.

  9. Contraband and threat material detection

    International Nuclear Information System (INIS)

    Lowrey, J. D.; Dunn, W.L.

    2008-01-01

    Full text: A pressing threat in modern society is the effective use of improvised explosive devices or IED's. One of the commonly used techniques to detect explosives is radiography. A primary drawback of this method is that humans are required in order to examine the image of each target. This requires trained personnel, who are subject to fatigue if many targets are being examined in rapid succession. Other trace element techniques generally require collection of samples from or near the surface of suspect targets. The signature-based radiation scanning (SBRS) technology has been developed to counter this threat. This technology can result in automated systems, requiring minimal operator involvement, that can rapidly identify IEDs from standoff. Preliminary research indicates that explosive samples of 5-10 kg or greater hidden in various targets can be detected from standoffs of more than a meter, with high sensitivity and high specificity. Many common explosives have similar concentrations of hydrogen, carbon, nitrogen and oxygen (HCNO). As neutrons interact with HCNO materials, unique signatures are created based on the specific composition of the material. We collect signatures from the HCNO prompt and inelastically scattered gamma rays and from scattered neutrons. Two neutron detectors (one bare and one cadmium-covered) are used in order to provide some measure of the back-scattered neutron spectrum. A library of signature templates, based on signatures detected from known targets containing known explosives in various configurations, is created. Similar signatures can be collected for suspect targets. Then a template-matching technique is used to construct two figure-of-merit metrics. The values of these metrics can be used to differentiate between safe targets and IEDs. Laboratory tests have been conducted using a high purity Germanium (HPGe) detector and two europium-doped lithium-iodide neutron detectors (one bare and one covered with cadmium) are used to

  10. 75 FR 29357 - Notice of Availability of the Draft Programmatic Environmental Assessment for the Deployment and...

    Science.gov (United States)

    2010-05-25

    ... technology that is used to aid in inspecting high-density cargo containers for contraband such as illicit... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Notice of Availability of the Draft Programmatic Environmental Assessment for the Deployment and Operation of High Energy X-Ray...

  11. Spectrum interrogation of fiber acoustic sensor based on self-fitting and differential method.

    Science.gov (United States)

    Fu, Xin; Lu, Ping; Ni, Wenjun; Liao, Hao; Wang, Shun; Liu, Deming; Zhang, Jiangshan

    2017-02-20

    In this article, we propose an interrogation method of fiber acoustic sensor to recover the time-domain signal from the sensor spectrum. The optical spectrum of the sensor will show a ripple waveform when responding to acoustic signal due to the scanning process in a certain wavelength range. The reason behind this phenomenon is the dynamic variation of the sensor spectrum while the intensity of different wavelength is acquired at different time in a scanning period. The frequency components can be extracted from the ripple spectrum assisted by the wavelength scanning speed. The signal is able to be recovered by differential between the ripple spectrum and its self-fitted curve. The differential process can eliminate the interference caused by environmental perturbations such as temperature or refractive index (RI), etc. The proposed method is appropriate for fiber acoustic sensors based on gratings or interferometers. A long period grating (LPG) is adopted as an acoustic sensor head to prove the feasibility of the interrogation method in experiment. The ability to compensate the environmental fluctuations is also demonstrated.

  12. Optically powered and interrogated rotary position sensor for aircraft engine control applications

    Science.gov (United States)

    Spillman, W. B.; Crowne, D. H.; Woodward, D. W.

    A throttle level angle (TLA) sensing system is described that utilizes a capacitance based rotary position transducer that is powered and interrogated via light from a single multimode optical fiber. The system incorporates a unique GaAs device that serves as both a power converter and optical data transmitter. Design considerations are discussed, and the fabrication and performance of the sensor system are detailed.

  13. Active Interrogation using Photofission Technique for Nuclear Materials Control and Accountability

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Haori [Oregon State Univ., Corvallis, OR (United States)

    2016-03-31

    Innovative systems with increased sensitivity and resolution are in great demand to detect diversion and to prevent misuse in support of nuclear materials management for the U.S. fuel cycle. Nuclear fission is the most important multiplicative process involved in non-destructive active interrogation. This process produces the most easily recognizable signature for nuclear materials. In addition to thermal or high-energy neutrons, high-energy gamma rays can also excite a nucleus and cause fission through a process known as photofission. Electron linear accelerators (linacs) are widely used as the interrogating photon sources for inspection methods involving photofission technique. After photofission reactions, prompt signals are much stronger than the delayed signals, but it is difficult to quantify them in practical measurements. Delayed signals are easily distinguishable from the interrogating radiation. Linac-based, advanced inspection techniques utilizing the delayed signals after photofission have been extensively studied for homeland security applications. Previous research also showed that a unique delayed gamma ray energy spectrum exists for each fissionable isotope. In this work, high-energy delayed γ-rays were demonstrated to be signatures for detection, identification, and quantification of special nuclear materials. Such γ-rays were measured in between linac pulses using independent data acquisition systems. A list-mode system was developed to measure low-energy delayed γ-rays after irradiation. Photofission product yields of 238U and 239Pu were determined based on the measured delayed γ-ray spectra. The differential yields of delayed γ-rays were also proven to be able to discriminate nuclear from non-nuclear materials. The measurement outcomes were compared with Monte Carlo simulation results. It was demonstrated that the current available codes have capabilities and limitations in the simulation of photofission process. A two

  14. Active Interrogation using Photofission Technique for Nuclear Materials Control and Accountability

    International Nuclear Information System (INIS)

    Yang, Haori

    2016-01-01

    Innovative systems with increased sensitivity and resolution are in great demand to detect diversion and to prevent misuse in support of nuclear materials management for the U.S. fuel cycle. Nuclear fission is the most important multiplicative process involved in non-destructive active interrogation. This process produces the most easily recognizable signature for nuclear materials. In addition to thermal or high-energy neutrons, high-energy gamma rays can also excite a nucleus and cause fission through a process known as photofission. Electron linear accelerators (linacs) are widely used as the interrogating photon sources for inspection methods involving photofission technique. After photofission reactions, prompt signals are much stronger than the delayed signals, but it is difficult to quantify them in practical measurements. Delayed signals are easily distinguishable from the interrogating radiation. Linac-based, advanced inspection techniques utilizing the delayed signals after photofission have been extensively studied for homeland security applications. Previous research also showed that a unique delayed gamma ray energy spectrum exists for each fissionable isotope. In this work, high-energy delayed γ-rays were demonstrated to be signatures for detection, identification, and quantification of special nuclear materials. Such γ-rays were measured in between linac pulses using independent data acquisition systems. A list-mode system was developed to measure low-energy delayed γ-rays after irradiation. Photofission product yields of 238 U and 239 Pu were determined based on the measured delayed γ-ray spectra. The differential yields of delayed γ-rays were also proven to be able to discriminate nuclear from non-nuclear materials. The measurement outcomes were compared with Monte Carlo simulation results. It was demonstrated that the current available codes have capabilities and limitations in the simulation of photofission process. A two-fold approach was

  15. Scoping studies - photon and low energy neutron interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Becker, G.; Harker, Y.; Jones, J. [LMITCo, Idaho Falls, ID (United States); Harmon, F. [Idaho State Univ., Pocatello, ID (United States)

    1997-11-01

    High energy photon interrogation of waste containers, with the aim of producing photo nuclear reactions, in specific materials, holds the potential of good penetration and rapid analysis. Compact high energy ({le} 10 MeV) photon sources in the form of electron linacs producing bremstrahlung radiation are readily available. Work with the Varitron variable energy accelerator at ISU will be described. Advantages and limitations of the technique will be discussed. Using positive ion induced neutron producing reactions, it is possible to generate neutrons in a specific energy range. By this means, variable penetration and specific reactions can be excited in the assayed material. Examples using the {sup 3}H(p,n) and {sup 7}Li(p,n) reactions as neutron sources will be discussed. 4 refs., 7 figs.

  16. Image-preprocessing method for near-wall particle image velocimetry (PIV) image interrogation with very large in-plane displacement

    International Nuclear Information System (INIS)

    Zhu, Yiding; Yuan, Huijing; Zhang, Chuanhong; Lee, Cunbiao

    2013-01-01

    Accurate particle image velocimetry (PIV) measurements very near the wall are still a great challenge. The problem is compounded by the very large in-plane displacement on PIV images commonly encountered in measurements in hypersonic boundary layers. An improved image-preprocessing method is presented in this paper which expands the traditional window deformation iterative multigrid scheme to PIV images with very large displacement. Before the interrogation, stationary artificial particles of uniform size are added homogeneously in the wall region. The mean squares of the intensities of signals in the flow and in the wall region are postulated to be equal when half the initial interrogation window overlaps the wall region. The initial estimation near the wall is then smoothed by data from both sides of the shear layer to reduce the large random uncertainties. Interrogations in the following iterative steps then converge to the correct results to provide accurate predictions for particle tracking velocimetries. Significant improvement is seen in Monte Carlo simulations and experimental tests. The algorithm successfully extracted the small flow structures of the second-mode wave in the hypersonic boundary layer from PIV images with low signal-noise-ratios when the traditional method was not successful. (paper)

  17. Touching is believing: interrogating halide perovskite solar cells at the nanoscale via scanning probe microscopy

    Science.gov (United States)

    Li, Jiangyu; Huang, Boyuan; Nasr Esfahani, Ehsan; Wei, Linlin; Yao, Jianjun; Zhao, Jinjin; Chen, Wei

    2017-10-01

    Halide perovskite solar cells based on CH3NH3PbI3 and related materials have emerged as the most exciting development in the next generation photovoltaic technologies, yet the microscopic phenomena involving photo-carriers, ionic defects, spontaneous polarization, and molecular vibration and rotation interacting with numerous grains, grain boundaries, and interfaces are still inadequately understood. In fact, there is still need for an effective method to interrogate the local photovoltaic properties of halide perovskite solar cells that can be directly traced to their microstructures on one hand and linked to their device performance on the other hand. In this perspective, we propose that scanning probe microscopy (SPM) techniques have great potential to realize such promises at the nanoscale, and highlight some of the recent progresses and challenges along this line of investigation toward local probing of photocurrent, work function, ionic activities, polarization switching, and chemical degradation. We also emphasize the importance of multi-modality imaging, in-operando scanning, big data analysis, and multidisciplinary collaboration for further studies toward fully understanding of these complex systems.

  18. Guidelines to indirectly measure and enhance detection efficiency of stationary PIT tag interrogation systems in streams

    Science.gov (United States)

    Connolly, Patrick J.; Wolf, Keith; O'Neal, Jennifer S.

    2010-01-01

    With increasing use of passive integrated transponder (PIT) tags and reliance on stationary PIT tag interrogation systems to monitor fish populations, guidelines are offered to inform users how best to use limited funding and human resources to create functional systems that maximize a desired level of detection and precision. The estimators of detection efficiency and their variability as described by Connolly et al. (2008) are explored over a span of likely performance metrics. These estimators were developed to estimate detection efficiency without relying on a known number of fish passing the system. I present graphical displays of the results derived from these estimators to show the potential efficiency and precision to be gained by adding an array or by increasing the number of PIT-tagged fish expected to move past an interrogation system.

  19. Electronics system for transuranic waste assays using a photon interrogation technique

    International Nuclear Information System (INIS)

    Johnson, L.O.; Lawrence, R.S.

    1979-12-01

    This report documents the development of electronics for a neutron detection system used in experiments to demonstrate the feasibility of a photon interrogation technique for transuranic (TRU) waste assays. The system consists of the neutron detection and signal conditioning circuits, variable time-gate generators, and a data acquisition system. The data acquisition system is configured using commercially available scalers, timers, teletype, and control components. The remainder of the system, with the exception of the neutron detectors, uses components designed in-house. The neutron detection system consists of 3 He proportional counters installed in a polyethylene moderator assembly. The counters are direct-coupled to a high-count-rate, current-sensitive preamplifier. The preamplifier and an additional two-stage amplifier are also installed in the moderator assembly. Signal conditioning includes baseline restoration and fast discrimination. A variable time-gate generator with logic gates allows for separation of prompt and delayed neutron counts, and generation of prompt and delayed deadtimes. The 3 He proportional counters will detect not only the neutrons from the TRU waste sample, but also the high-energy photons used to induce fission in the sample. The burst of photons (gamma flash) tends to overload and paralyze the electronics. This system has been designed to recover from a worst-case gamma flash overload within 10 microseconds. The system has met all the requirements generated for the photon interrogation experiments

  20. Fissile materials in solution concentration measured by active neutron interrogation; Mesure de concentration en matiere fissile dans les liquides par interrogation neutronique active

    Energy Technology Data Exchange (ETDEWEB)

    Romeyer Dherbey, J.; Passard, Ch.; Cloue, J.; Bignan, G.

    1993-12-31

    The use of the active neutron interrogation to measure the concentration of plutonium contained in flow solutions is particularly interesting for fuel reprocessing plants. Indeed, this method gives a signal which is in a direct relation with the fissile materials concentration. Moreover, it is less sensitive to the gamma dose rate than the other nondestructive methods. Two measure methods have been evolved in CEA. Their principles are given into details in this work. The first one consists to detect fission delayed neutrons induced by a {sup 252} Cf source. In the second one fission prompt neutrons induced by a neutron generator of 14 MeV are detected. (O.M.). 6 refs.

  1. Towards Transnational Feminisms. Some reflections and concerns in relation to the globalization of reproductive technologies

    NARCIS (Netherlands)

    Gupta, J.A.

    2006-01-01

    This article discusses the emergence of the concept of ‘transnational feminisms’ as a differentiated notion from ‘global sisterhood’ within feminist postcolonial criticism. This is done in order to examine its usefulness for interrogating the globalization of reproductive technologies and women’s

  2. Facilitating biomedical researchers' interrogation of electronic health record data: Ideas from outside of biomedical informatics.

    Science.gov (United States)

    Hruby, Gregory W; Matsoukas, Konstantina; Cimino, James J; Weng, Chunhua

    2016-04-01

    Electronic health records (EHR) are a vital data resource for research uses, including cohort identification, phenotyping, pharmacovigilance, and public health surveillance. To realize the promise of EHR data for accelerating clinical research, it is imperative to enable efficient and autonomous EHR data interrogation by end users such as biomedical researchers. This paper surveys state-of-art approaches and key methodological considerations to this purpose. We adapted a previously published conceptual framework for interactive information retrieval, which defines three entities: user, channel, and source, by elaborating on channels for query formulation in the context of facilitating end users to interrogate EHR data. We show the current progress in biomedical informatics mainly lies in support for query execution and information modeling, primarily due to emphases on infrastructure development for data integration and data access via self-service query tools, but has neglected user support needed during iteratively query formulation processes, which can be costly and error-prone. In contrast, the information science literature has offered elaborate theories and methods for user modeling and query formulation support. The two bodies of literature are complementary, implying opportunities for cross-disciplinary idea exchange. On this basis, we outline the directions for future informatics research to improve our understanding of user needs and requirements for facilitating autonomous interrogation of EHR data by biomedical researchers. We suggest that cross-disciplinary translational research between biomedical informatics and information science can benefit our research in facilitating efficient data access in life sciences. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Massively Parallel Interrogation of Aptamer Sequence, Structure and Function

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, N O; Tok, J B; Tarasow, T M

    2008-02-08

    Optimization of high affinity reagents is a significant bottleneck in medicine and the life sciences. The ability to synthetically create thousands of permutations of a lead high-affinity reagent and survey the properties of individual permutations in parallel could potentially relieve this bottleneck. Aptamers are single stranded oligonucleotides affinity reagents isolated by in vitro selection processes and as a class have been shown to bind a wide variety of target molecules. Methodology/Principal Findings. High density DNA microarray technology was used to synthesize, in situ, arrays of approximately 3,900 aptamer sequence permutations in triplicate. These sequences were interrogated on-chip for their ability to bind the fluorescently-labeled cognate target, immunoglobulin E, resulting in the parallel execution of thousands of experiments. Fluorescence intensity at each array feature was well resolved and shown to be a function of the sequence present. The data demonstrated high intra- and interchip correlation between the same features as well as among the sequence triplicates within a single array. Consistent with aptamer mediated IgE binding, fluorescence intensity correlated strongly with specific aptamer sequences and the concentration of IgE applied to the array. The massively parallel sequence-function analyses provided by this approach confirmed the importance of a consensus sequence found in all 21 of the original IgE aptamer sequences and support a common stem:loop structure as being the secondary structure underlying IgE binding. The microarray application, data and results presented illustrate an efficient, high information content approach to optimizing aptamer function. It also provides a foundation from which to better understand and manipulate this important class of high affinity biomolecules.

  4. Massively parallel interrogation of aptamer sequence, structure and function.

    Directory of Open Access Journals (Sweden)

    Nicholas O Fischer

    Full Text Available BACKGROUND: Optimization of high affinity reagents is a significant bottleneck in medicine and the life sciences. The ability to synthetically create thousands of permutations of a lead high-affinity reagent and survey the properties of individual permutations in parallel could potentially relieve this bottleneck. Aptamers are single stranded oligonucleotides affinity reagents isolated by in vitro selection processes and as a class have been shown to bind a wide variety of target molecules. METHODOLOGY/PRINCIPAL FINDINGS: High density DNA microarray technology was used to synthesize, in situ, arrays of approximately 3,900 aptamer sequence permutations in triplicate. These sequences were interrogated on-chip for their ability to bind the fluorescently-labeled cognate target, immunoglobulin E, resulting in the parallel execution of thousands of experiments. Fluorescence intensity at each array feature was well resolved and shown to be a function of the sequence present. The data demonstrated high intra- and inter-chip correlation between the same features as well as among the sequence triplicates within a single array. Consistent with aptamer mediated IgE binding, fluorescence intensity correlated strongly with specific aptamer sequences and the concentration of IgE applied to the array. CONCLUSION AND SIGNIFICANCE: The massively parallel sequence-function analyses provided by this approach confirmed the importance of a consensus sequence found in all 21 of the original IgE aptamer sequences and support a common stem:loop structure as being the secondary structure underlying IgE binding. The microarray application, data and results presented illustrate an efficient, high information content approach to optimizing aptamer function. It also provides a foundation from which to better understand and manipulate this important class of high affinity biomolecules.

  5. Nanochannel Electroporation as a Platform for Living Cell Interrogation in Acute Myeloid Leukemia.

    Science.gov (United States)

    Zhao, Xi; Huang, Xiaomeng; Wang, Xinmei; Wu, Yun; Eisfeld, Ann-Kathrin; Schwind, Sebastian; Gallego-Perez, Daniel; Boukany, Pouyan E; Marcucci, Guido I; Lee, Ly James

    2015-12-01

    A living cell interrogation platform based on nanochannel electroporation is demonstrated with analysis of RNAs in single cells. This minimally invasive process is based on individual cells and allows both multi-target analysis and stimulus-response analysis by sequential deliveries. The unique platform possesses a great potential to the comprehensive and lysis-free nucleic acid analysis on rare or hard-to-transfect cells.

  6. Development and application of a hybrid transport methodology for active interrogation systems

    Energy Technology Data Exchange (ETDEWEB)

    Royston, K.; Walters, W.; Haghighat, A. [Nuclear Engineering Program, Department of Mechanical Engineering, Virginia Tech., 900 N Glebe Rd., Arlington, VA 22203 (United States); Yi, C.; Sjoden, G. [Nuclear and Radiological Engineering, Georgia Tech, 801 Ferst Drive, Atlanta, GA 30332 (United States)

    2013-07-01

    A hybrid Monte Carlo and deterministic methodology has been developed for application to active interrogation systems. The methodology consists of four steps: i) neutron flux distribution due to neutron source transport and subcritical multiplication; ii) generation of gamma source distribution from (n, 7) interactions; iii) determination of gamma current at a detector window; iv) detection of gammas by the detector. This paper discusses the theory and results of the first three steps for the case of a cargo container with a sphere of HEU in third-density water cargo. To complete the first step, a response-function formulation has been developed to calculate the subcritical multiplication and neutron flux distribution. Response coefficients are pre-calculated using the MCNP5 Monte Carlo code. The second step uses the calculated neutron flux distribution and Bugle-96 (n, 7) cross sections to find the resulting gamma source distribution. In the third step the gamma source distribution is coupled with a pre-calculated adjoint function to determine the gamma current at a detector window. The AIMS (Active Interrogation for Monitoring Special-Nuclear-Materials) software has been written to output the gamma current for a source-detector assembly scanning across a cargo container using the pre-calculated values and taking significantly less time than a reference MCNP5 calculation. (authors)

  7. Bayesian variable selection for post-analytic interrogation of susceptibility loci.

    Science.gov (United States)

    Chen, Siying; Nunez, Sara; Reilly, Muredach P; Foulkes, Andrea S

    2017-06-01

    Understanding the complex interplay among protein coding genes and regulatory elements requires rigorous interrogation with analytic tools designed for discerning the relative contributions of overlapping genomic regions. To this aim, we offer a novel application of Bayesian variable selection (BVS) for classifying genomic class level associations using existing large meta-analysis summary level resources. This approach is applied using the expectation maximization variable selection (EMVS) algorithm to typed and imputed SNPs across 502 protein coding genes (PCGs) and 220 long intergenic non-coding RNAs (lncRNAs) that overlap 45 known loci for coronary artery disease (CAD) using publicly available Global Lipids Gentics Consortium (GLGC) (Teslovich et al., 2010; Willer et al., 2013) meta-analysis summary statistics for low-density lipoprotein cholesterol (LDL-C). The analysis reveals 33 PCGs and three lncRNAs across 11 loci with >50% posterior probabilities for inclusion in an additive model of association. The findings are consistent with previous reports, while providing some new insight into the architecture of LDL-cholesterol to be investigated further. As genomic taxonomies continue to evolve, additional classes such as enhancer elements and splicing regions, can easily be layered into the proposed analysis framework. Moreover, application of this approach to alternative publicly available meta-analysis resources, or more generally as a post-analytic strategy to further interrogate regions that are identified through single point analysis, is straightforward. All coding examples are implemented in R version 3.2.1 and provided as supplemental material. © 2016, The International Biometric Society.

  8. Neutron interrogator assay system for the Idaho Chemical Processing Plant waste canisters and spent fuel: preliminary description and operating procedures manual

    International Nuclear Information System (INIS)

    Menlove, H.O.; Eccleston, G.; Close, D.A.; Speir, L.G.

    1978-05-01

    A neutron interrogation assay system is being designed for the measurement of waste canisters and spent fuel packages at the new Idaho Chemical Processing Plant to be operated by Allied Chemical Corp. The assay samples consist of both waste canisters from the fluorinel dissolution process and spent fuel assemblies. The assay system is a 252 Cf ''Shuffler'' that employs a cyclic sequence of fast-neutron interrogation with a 252 Cf source followed by delayed-neutron counting to determine the 235 U content

  9. Queering marriage: an ideographic interrogation of heteronormative subjectivity.

    Science.gov (United States)

    Grindstaff, Davin

    2003-01-01

    Recent debates on same-sex marriage mark the institution, practice, and concept of marriage as a significant site of power and resistance within American culture. Adopting Michel Foucault's conception of "discipline," this essay examines how marriage discourse reinforces heteronormative power relations through its rhetorical constitution of gay male identity. Supplementing "ideographic" critique with Judith Butler's theory of performative speech acts enables us to better interrogate and resist these operations of power. This essay maps the contemporary scene of heteronormative power and resistance through two rhetorical performances of gay male identity. The marriage debates, in the first instance, demonstrate how a conventional desire for masculine agency influences the heteronormative production of gay male identity. In the second instance, gay male SM [sadomasochism] performs a concept of "relational agency," which potentially resists heteronormativity.

  10. Characterization of lipid films by an angle-interrogation surface plasmon resonance imaging device.

    Science.gov (United States)

    Liu, Linlin; Wang, Qiong; Yang, Zhong; Wang, Wangang; Hu, Ning; Luo, Hongyan; Liao, Yanjian; Zheng, Xiaolin; Yang, Jun

    2015-04-01

    Surface topographies of lipid films have an important significance in the analysis of the preparation of giant unilamellar vesicles (GUVs). In order to achieve accurately high-throughput and rapidly analysis of surface topographies of lipid films, a homemade SPR imaging device is constructed based on the classical Kretschmann configuration and an angle interrogation manner. A mathematical model is developed to accurately describe the shift including the light path in different conditions and the change of the illumination point on the CCD camera, and thus a SPR curve for each sampling point can also be achieved, based on this calculation method. The experiment results show that the topographies of lipid films formed in distinct experimental conditions can be accurately characterized, and the measuring resolution of the thickness lipid film may reach 0.05 nm. Compared with existing SPRi devices, which realize detection by monitoring the change of the reflective-light intensity, this new SPRi system can achieve the change of the resonance angle on the entire sensing surface. Thus, it has higher detection accuracy as the traditional angle-interrogation SPR sensor, with much wider detectable range of refractive index. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. [Performance of a standardized interrogation to improve the screening of Chlamydia trachomatis infection].

    Science.gov (United States)

    Grandcolin, S; de Hauteclocque, A; Lafoscade, A; Fritel, X

    2015-10-01

    To estimate the performance of a standardized interrogation tool facilitating the detection and screening of patients for the Chlamydia trachomatis infection, to estimate the prevalence of the infection in the family planning population studied. Prospective observational study, including the patients who had a consultation in the abortion center in the CHU of Poitiers. A sampling of the cervix was systematically carried out after the standardized interrogation in search of four clinical signs. The samples were analyzed by genetic amplification. Three hundred and eighty-six women were included and 56 (14.5 %) infections were identified. The medical history questionnaire was relatively effective for 2 or 3 clinical signs. The positive predictive value (PPV) was respectively 34.8 % and 53.8 % and was very relevant for 4 clinical signs with PPV at 83.3 % [CI 95 %: 74-93 %]. Among the infected women, 48.2 % had no clinical sign revealed by the medical history questionnaire. The presence of any clinical sign was strongly associated with the C. trachomatis infection (Pinterrogation are all significantly associated with the C. trachomatis infection. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. The recognition of acted interpersonal stance in police interrogations and the influence of actor proficiency

    NARCIS (Netherlands)

    Bruijnes, Merijn; op den Akker, Hendrikus J.A.; Spitters, Sophie; Sanders, Merijn; Fu, Quihua

    2015-01-01

    This paper reports on judgement studies regarding the perception of interpersonal stances taken by humans playing the role of a suspect in a police interrogation setting. Our project aims at building believable embodied conversational characters to play the role of suspects in a serious game for

  13. Compact multichannel high-resolution micro-electro-mechanical systems-based interrogator for Fiber Bragg grating sensing

    DEFF Research Database (Denmark)

    Ganziy, Denis; Rose, Bjarke; Bang, Ole

    2017-01-01

    We propose a novel type of compact high-resolution multichannel micro-electro-mechanical systems (MEMS)-based interrogator, where we replace the linear detector with a digital micromirror device (DMD). The DMD is typically cheaper and has better pixel sampling than an InGaAs detector used...

  14. Switching Transient Generation in Surface Interrogation Scanning Electrochemical Microscopy and Time-of-Flight Techniques.

    Science.gov (United States)

    Ahn, Hyun S; Bard, Allen J

    2015-12-15

    In surface interrogation scanning electrochemical microscopy (SI-SECM), fine and accurate control of the delay time between substrate generation and tip interrogation (tdelay) is crucial because tdelay defines the decay time of the reactive intermediate. In previous applications of the SI-SECM, the resolution in the control of tdelay has been limited to several hundreds of milliseconds due to the slow switching of the bipotentiostat. In this work, we have improved the time resolution of tdelay control up to ca. 1 μs, enhancing the SI-SECM to be competitive in the time domain with the decay of many reactive intermediates. The rapid switching SI-SECM has been implemented in a substrate generation-tip collection time-of-flight (SG-TC TOF) experiment of a solution redox mediator, and the results obtained from the experiment exhibited good agreement with that obtained from digital simulation. The reaction rate constant of surface Co(IV) on oxygen-evolving catalyst film, which was inaccessible thus far due to the lack of tdelay control, has been measured by the rapid switching SI-SECM.

  15. Campus-Based Student Experiences of Learning Technologies in a First-Year Science Course

    Science.gov (United States)

    Ellis, Robert; Weyers, Mark; Hughes, Jane

    2013-01-01

    This study reports on an investigation into the campus-based experience of university students studying mammalian physiology that was significantly supported with learning technologies. The design of the course enabled the students to interrogate the key ideas that they came across in their lectures and laboratories through online activities which…

  16. The relationship of intelligence and memory to interrogative suggestibility: the importance of range effects.

    Science.gov (United States)

    Gudjonsson, G H

    1988-05-01

    This paper looks at the relationship between intelligence, memory and interrogative suggestibility, particularly with reference to range effects. The subjects were 60 normal subjects and 100 forensic patients who had completed the Gudjonsson Suggestibility Scale (GSS) and the Wechsler Adult Intelligence Scale. Clear range effects of IQ and memory were evident in their relationship with suggestibility.

  17. Intrathecal Pump Exposure to Electromagnetic Interference: A Report of Device Interrogation following Multiple ECT Sessions.

    Science.gov (United States)

    Bicket, Mark C; Hanna, George M

    2016-02-01

    Intrathecal drug delivery systems represent an increasingly common treatment modality for patients with a variety of conditions, including chronic pain and spasticity. Pumps rely on electronic programming to properly control and administer highly concentrated medications. Electromagnetic interference (EMI) is a known exposure that may cause a potential patient safety issue stemming from direct patient injury, pump damage, or changes to pump operation or flow rate. The objective of our case report was to describe an approach to evaluating a patient with a pump prior to and following exposure to EMI from electroconvulsive therapy (ECT), as well as to document findings from device interrogations associated with this event. Case report. Academic university-based pain management center. We present the case of a patient with an intrathecal pump who underwent multiple exposures to EMI in the form of 42 ECT sessions. Interrogation of the intrathecal drug delivery system revealed no safety issues following ECT sessions. At no time were error messages, unintentional changes in event logs, unintentional changes in pump settings, or evidence of pump stall or over-infusion noted. Communication with multiple entities (patient, family, consulting physicians, and device manufacturer) and maintaining vigilance through device interrogation both before and after EMI exposure are appropriate safeguards to mitigate the risk and detect potential adverse events of EMI with intrathecal drug delivery systems. Given the infrequent reports of device exposure to ECT, best practices may be derived from experience with EMI exposure from magnetic resonance imaging (MRI). Although routine EMI exposure to intrathecal drug delivery systems should be avoided, we describe one patient with repeated exposure to ECT without apparent complication.

  18. 75 FR 61770 - Notice of Availability of the Final Programmatic Environmental Assessment and Finding of No...

    Science.gov (United States)

    2010-10-06

    ... inspection technology that is used to scan high-density cargo containers for contraband such as illicit drugs... DEPARTMENT OF HOMELAND SECURITY U.S. Customs and Border Protection Notice of Availability of the... Operation of High Energy X-Ray Inspection Systems at Sea and Land Ports of Entry AGENCY: U.S. Customs and...

  19. X-ray and neutron interrogation of air cargo for mobile applications

    Energy Technology Data Exchange (ETDEWEB)

    Van Liew, Seth

    2015-06-01

    A system for scanning break-bulk cargo for mobile applications is presented. This combines a 140 kV multi-view, multi-energy X-ray system with 2.5 MeV neutrons. The system uses dual energy X-ray radiography with neutron radiography. The X-ray and neutron systems were designed to be collocated in a mobile environment. Various materials were interrogated with the intent of distinguishing threat materials such as explosives from similar benign materials. In particular, the identification of threats and bengins with nearly identical effective atomic numbers has been demonstrated.

  20. X-ray and neutron interrogation of air cargo for mobile applications

    International Nuclear Information System (INIS)

    Van Liew, Seth

    2015-01-01

    A system for scanning break-bulk cargo for mobile applications is presented. This combines a 140 kV multi-view, multi-energy X-ray system with 2.5 MeV neutrons. The system uses dual energy X-ray radiography with neutron radiography. The X-ray and neutron systems were designed to be collocated in a mobile environment. Various materials were interrogated with the intent of distinguishing threat materials such as explosives from similar benign materials. In particular, the identification of threats and bengins with nearly identical effective atomic numbers has been demonstrated

  1. Interrogative Utterances in Surah Al-Baqarah

    Directory of Open Access Journals (Sweden)

    Aly Bayoumy AIi Oteify

    1993-11-01

    Full Text Available The Qur’an is singularly distinctive in its style compared to any human composition. Human eloquence, with its remarkable history in the composition of poetry, has failed to compose even a single verse like that of the Qur'an. The Qur'anic composition is a living challenge for human beings to imitate its miraculous style. This inimitable aspect of the Qur'an, among other things, proves that it was revealed by Allah (SWT to Prophet Muhammad (SAAS. In addition, the miracle of its linguistic composition was a means to declare the faith based on monotheism and the introduction of a new order and a theo-centric guidance that was meant to unite humanity. Adopting the monotheistic faith gave rise to a new community, the Muslim ummah that was able to bridge the differences between human beings in culture, race, colour and geographical boundaries. Consequently, the unique style of the Qur’an deserves a careful study. The present study investigates the use of interrogative utterances in surah al-Baqarah and their contribution to the Qur'an's rhetorical style. Hopefully, the results of this study will be useful in later investigations of other parts of the Qur' an...

  2. Fissile materials in solution concentration measured by active neutron interrogation

    International Nuclear Information System (INIS)

    Romeyer Dherbey, J.; Passard, Ch.; Cloue, J.; Bignan, G.

    1993-01-01

    The use of the active neutron interrogation to measure the concentration of plutonium contained in flow solutions is particularly interesting for fuel reprocessing plants. Indeed, this method gives a signal which is in a direct relation with the fissile materials concentration. Moreover, it is less sensitive to the gamma dose rate than the other nondestructive methods. Two measure methods have been evolved in CEA. Their principles are given into details in this work. The first one consists to detect fission delayed neutrons induced by a 252 Cf source. In the second one fission prompt neutrons induced by a neutron generator of 14 MeV are detected. (O.M.)

  3. Integrated Si-based nanoplasmonic sensor with phase-sensitive angular interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Patskovsky, Sergiy; Meunier, Michel [Laser Processing and Plasmonics Laboratory, Ecole Polytechnique de Montreal, C. P. 6079, succ. Centre-Ville, Montreal, QC, H3C 3A7 (Canada)

    2013-06-15

    This work is related to the development of an integrated Surface Plasmon Resonance (SPR) sensor on silicon platform. The optical properties of metallic nanogratings fabricated on the semiconductor structure allow direct plasmonic detection in transmission mode. Specially designed angular interrogation method provides a periodic signal with phase dependent on the conditions of surface plasmon excitation. Proposed technique leads to sensitivity better than 10{sup -6} RIU for conventional SPR Kretschmann configuration and was tested on the integrated Si-based nanoplasmonic chip. Developed concept is promising for low-cost mono and multi -sensing applications by portable or stationary platforms. (copyright 2013 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Interrogative suggestibility, compliance and false confessions among prisoners and their relationship with attention deficit hyperactivity disorder (ADHD) symptoms.

    Science.gov (United States)

    Gudjonsson, G H; Sigurdsson, J F; Bragason, O O; Newton, A K; Einarsson, E

    2008-07-01

    Interrogative suggestibility and compliance are important psychological vulnerabilities during interrogation. The aim of the study was to investigate the relationship of suggestibility and compliance with childhood and current symptoms of attention deficit hyperactivity disorder (ADHD). Compliance has not been studied previously in relation to ADHD. A further aim was to investigate the relationship between ADHD and the reporting of having made a false confession to the police. The participants were 90 male prisoners, all of whom had completed the Gudjonsson Suggestibility and Compliance Scales (GSS and GCS) within 10 days of admission to the prison. Childhood ADHD symptoms were screened by the Wender Utah Rating Scale (WURS) and current adult symptoms by the DSM-IV Checklist criteria for ADHD. Half of the prisoners (50%) were found on screening to meet criteria for ADHD in childhood and, of those, over half (60%) were either fully symptomatic or in partial remission of their symptoms. ADHD symptoms were found to be significantly associated with compliance, but not with suggestibility. The relationship with compliance was stronger (effect size) in relation to current than childhood symptoms. The ADHD symptomatic groups were significantly more likely to claim that they had made a false confession to the police in the past. The findings raise important questions about the potential vulnerability of adults with ADHD symptoms in terms of their ability to cope with interrogation.

  5. Assessment of damage in composite laminates through dynamic, full-spectral interrogation of fiber Bragg grating sensors

    International Nuclear Information System (INIS)

    Propst, A; Peters, K; Zikry, M A; Schultz, S; Kunzler, W; Zhu, Z; Wirthlin, M; Selfridge, R

    2010-01-01

    In this study, we demonstrate the full-spectral interrogation of a fiber Bragg grating (FBG) sensor at 535 Hz. The sensor is embedded in a woven, graphite fiber–epoxy composite laminate subjected to multiple low-velocity impacts. The measurement of unique, time dependent spectral features from the FBG sensor permits classification of the laminate lifetime into five regimes. These damage regimes compare well with previous analysis of the same material system using combined global and local FBG sensor information. Observed transient spectral features include peak splitting, wide spectral broadening and a strong single peak at the end of the impact event. Such features could not be measured through peak wavelength interrogation of the FBG sensor. Cross-correlation of the measured spectra with the original embedded FBG spectrum permitted rapid visualization of average strains and the presence of transverse compressive strain on the optical fiber, but smeared out the details of the spectral profile

  6. Genome interrogation for novel salinity tolerant Arabidopsis mutants.

    Science.gov (United States)

    van Tol, Niels; Pinas, Johan; Schat, Henk; Hooykaas, Paul J J; van der Zaal, Bert J

    2016-12-01

    Soil salinity is becoming an increasingly large problem in agriculture. In this study, we have investigated whether a capacity to withstand salinity can be induced in the salinity sensitive plant species Arabidopsis thaliana, and whether it can be maintained in subsequent generations. To this end, we have used zinc finger artificial transcription factor (ZF-ATFs) mediated genome interrogation. Already within a relatively small collection Arabidopsis lines expressing ZF-ATFs, we found 41 lines that were tolerant to 100 mM NaCl. Furthermore, ZF-ATF encoding gene constructs rescued from the most strongly salinity tolerant lines were indeed found to act as dominant and heritable agents for salinity tolerance. Altogether, our data provide evidence that a silent capacity to withstand normally lethal levels of salinity exists in Arabidopsis and can be evoked relatively easily by in trans acting transcription factors like ZF-ATFs. © 2016 John Wiley & Sons Ltd.

  7. Database management systems understanding and applying database technology

    CERN Document Server

    Gorman, Michael M

    1991-01-01

    Database Management Systems: Understanding and Applying Database Technology focuses on the processes, methodologies, techniques, and approaches involved in database management systems (DBMSs).The book first takes a look at ANSI database standards and DBMS applications and components. Discussion focus on application components and DBMS components, implementing the dynamic relationship application, problems and benefits of dynamic relationship DBMSs, nature of a dynamic relationship application, ANSI/NDL, and DBMS standards. The manuscript then ponders on logical database, interrogation, and phy

  8. An Alternative Approach: Examining Arguments Against Coercive Interrogation Techniques from a Biblical-Ethics Perspective

    Science.gov (United States)

    2016-06-10

    Ethics of Torture. Jeffreys is Associate Professor of Humanistic Studies and Religion at the University of Wisconsin, Green Bay (Jeffreys 2009... existential struggle of those suffering from MI is a result of “perpetrating, failing to prevent, or bearing witness to acts that transgress deeply held... existential impact of CIT on the interrogator. While neither offers a complete and substantiated theory, their comments provide further argumentation that

  9. Repetitive Interrogation of 2-Level Quantum Systems

    Science.gov (United States)

    Prestage, John D.; Chung, Sang K.

    2010-01-01

    Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.

  10. High Pressure Sensing and Dynamics Using High Speed Fiber Bragg Grating Interrogation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, G. [LANL; Sandberg, R. L. [LANL; Lalone, B. M. [NSTec; Marshall, B. R. [NSTec; Grover, M. [NSTec; Stevens, G. D. [NSTec; Udd, E. [Columbia Gorge Research

    2014-06-01

    Fiber Bragg gratings (FBGs) are developing into useful sensing tools for measuring high pressure dynamics in extreme environments under shock loading conditions. Approaches using traditional diode array coupled FBG interrogation systems are often limited to readout speeds in the sub-MHz range. For shock wave physics, required detection speeds approaching 100 MHz are desired. We explore the use of two types of FBG sensing systems that are aimed at applying this technology as embedded high pressure probes for transient shock events. Both approaches measure time resolved spectral shifts in the return light from short (few mm long) uniform FBGs at 1550 nm. In the first approach, we use a fiber coupled spectrometer to demultiplex spectral channels into an array (up to 12) of single element InGaAs photoreceivers. By monitoring the detectors during a shock impact event with high speed recording, we are able to track the pressure induced spectral shifting in FBG down to a time resolution of 20 ns. In the second approach, developed at the Special Technologies Lab, a coherent mode-locked fiber laser is used to illuminate the FBG sensor. After the sensor, wavelength-to-time mapping is accomplished with a chromatic dispersive element, and entire spectra are sampled using a single detector at the modelocked laser repetition rate of 50 MHz. By sampling with a 12 GHz InGaAs detector, direct wavelength mapping in time is recorded, and the pressure induced FBG spectral shift is sampled at 50 MHz. Here, the sensing systems are used to monitor the spectral shifts of FBGs that are immersed into liquid water and shock compressed using explosives. In this configuration, the gratings survive to pressures approaching 50 kbar. We describe both approaches and present the measured spectral shifts from the shock experiments.

  11. High pressure sensing and dynamics using high speed fiber Bragg grating interrogation systems

    Science.gov (United States)

    Rodriguez, G.; Sandberg, R. L.; Lalone, B. M.; Marshall, B. R.; Grover, M.; Stevens, G.; Udd, E.

    2014-06-01

    Fiber Bragg gratings (FBGs) are developing into useful sensing tools for measuring high pressure dynamics in extreme environments under shock loading conditions. Approaches using traditional diode array coupled FBG interrogation systems are often limited to readout speeds in the sub-MHz range. For shock wave physics, required detection speeds approaching 100 MHz are desired. We explore the use of two types of FBG sensing systems that are aimed at applying this technology as embedded high pressure probes for transient shock events. Both approaches measure time resolved spectral shifts in the return light from short (few mm long) uniform FBGs at 1550 nm. In the first approach, we use a fiber coupled spectrometer to demultiplex spectral channels into an array (up to 12) of single element InGaAs photoreceivers. By monitoring the detectors during a shock impact event with high speed recording, we are able to track the pressure induced spectral shifting in FBG down to a time resolution of 20 ns. In the second approach, developed at the Special Technologies Lab, a coherent mode-locked fiber laser is used to illuminate the FBG sensor. After the sensor, wavelength-to-time mapping is accomplished with a chromatic dispersive element, and entire spectra are sampled using a single detector at the modelocked laser repetition rate of 50 MHz. By sampling with a 12 GHz InGaAs detector, direct wavelength mapping in time is recorded, and the pressure induced FBG spectral shift is sampled at 50 MHz. Here, the sensing systems are used to monitor the spectral shifts of FBGs that are immersed into liquid water and shock compressed using explosives. In this configuration, the gratings survive to pressures approaching 50 kbar. We describe both approaches and present the measured spectral shifts from the shock experiments.

  12. Christian Marclay : « iconoclasme » musical et interrogation sur l’instrument

    Directory of Open Access Journals (Sweden)

    Marianne Massin

    2011-03-01

    Full Text Available Le travail de Christian Marclay, artiste multiforme, improvisateur et performer, explore systématiquement un espace au confluent des arts sonores et visuels (vidéo, photos, installations, sculptures. Comment réfléchir sur le son à travers les objets tangibles et les représentations visuelles qui le réifient ? Comment produire – par une pratique musicale de platiniste notamment – de nouveaux sons et de nouveaux rapports à la musique ? Ce double axe d’interrogation rencontre nécessairement la question de l’instrument. Iconoclasme musical dans la double lignée du mouvement punk et de Fluxus ? Ou /et interrogation sur le fonctionnement de l’instrument dans la pratique vive d’une musique à réinventer ? On voudrait suggérer qu’une telle approche esthétique peut nourrir l’approche ontologique de l’instrument et, en paraphrasant Nelson Goodman, poser la question « quand y a-t-il instrument ? ».Christian Marclay : Musical « iconoclasism » and an instrumental interrogative Christian Marclay a polyvalent/multiform artist who improvises and performs. His work systematically explores the artistic space where audio arts and visual arts (video, photos, installations and sculpture merge. How can sound be considered in relation to tangible objects and visual representations that give it some actuality ? How can new sounds and new relationships with music be produced by any musical output for example of a turntablist ? This bilateral enquiry necessarily confronts the topic of the instrument. Is it a musical iconoclasism in the dynamic of both punk and Fluxus ? Or/and a questioning of the way the instrument works while a vivid musical practice has to be reinvented? It is suggested that such an esthetical approach may feed the ontological approach of the instrument and, to paraphrase Nelson Goodman, ask the question “When is something an instrument ?”.

  13. INL Neutron Interrogation R and D: FY2010 MPACT End of Year Report

    International Nuclear Information System (INIS)

    Chichester, D.L.; Seabury, E.H.; Wharton, J.; Watson, S.M.

    2010-01-01

    Experiments have been carried out to investigate the feasibility and utility of using neutron interrogation and small-scale, portable prompt gamma-ray neutron activation analysis (PGNAA) instruments for assaying uranium for safeguards applications. Prior work has shown the potential of the PGNAA technique for assaying uranium using reactor-based neutron sources and high-yield electronic neutron generators (ENGs). In this project we adapted Idaho National Laboratory's portable isotopic neutron spectroscopy (PINS) PGNAA system for measuring natural-enrichment uranium yellowcake and metallic depleted uranium and highly enriched uranium. This work used 252Cf as well as deuterium-deuterium (DD) and deuterium-tritium (DT) ENGs. For PGNAA measurements a limiting factor when assaying large objects is the detector dead time due to fast-neutron scattering off of the uranium; this limits the maximum useable neutron source strength to O(107) neutrons per second. Under these conditions the low PGNAA reaction cross sections for uranium prohibited the collection of useful uranium PGNAA signatures from either the yellowcake or metallic uranium samples. Measurement of the decay product activation in these materials following irradiation in the PGNAA geometry similarly did not produce useful uranium activation product - fission product signatures. A customized irradiation geometry tailored to optimally thermalize the interrogation neutron source, intended only for generating long-lived activation products - fission products and not intended for PGNAA measurements, might be possible using small scale ENGs but an application need and a modeling simulation exercise would be recommended before advancing to experiments. Neutron interrogation PGNAA using a DT-ENG was found to be a quick and useful qualitative method for detecting the presence of oxygen in natural-enrichment uranium yellowcake. With a low effort of development work it would be reasonable to expect this measurement could be

  14. Asking for Action or Information? Crosslinguistic Comparison of Interrogative Functions in Early Child Cantonese and Mandarin

    Science.gov (United States)

    Li, Hui; Wong, Eileen Chin Mei; Tse, Shek Kam; Leung, Shing On; Ye, Qianling

    2015-01-01

    Request for information (RfI) is believed to be the universally dominant function of young children's questioning, whereas request for action (RfA) has been reported to be the leading interrogative form used in early child Cantonese. The possibility of crosslinguistic variability prompts further research and comparison with additional languages.…

  15. Those Who Know and Are Known: Students Using Ethnography to Interrogate Language and Literacy Ideologies

    Science.gov (United States)

    LeBlanc, Robert Jean

    2018-01-01

    Framing ethnography as a form of democratic inquiry, this study examines how the author worked with a group of Mexican and Vietnamese American adolescents to learn and apply ethnographic tools to interrogate language and literacy ideologies in their school and community. Examination of the students' findings reveals circulating ideologies and…

  16. Understanding the Signature Pedagogy of the Design Studio and the Opportunities for Its Technological Enhancement

    Science.gov (United States)

    Crowther, Phillip

    2013-01-01

    This paper presents an analysis of the studio as the signature pedagogy of design education. A number of theoretical models of learning, pedagogy, and education are used to interrogate the studio for its advantages and shortcomings, and to identify opportunities for the integration of new technologies and to explore the affordances that they…

  17. An improved ATAC-seq protocol reduces background and enables interrogation of frozen tissues.

    Science.gov (United States)

    Corces, M Ryan; Trevino, Alexandro E; Hamilton, Emily G; Greenside, Peyton G; Sinnott-Armstrong, Nicholas A; Vesuna, Sam; Satpathy, Ansuman T; Rubin, Adam J; Montine, Kathleen S; Wu, Beijing; Kathiria, Arwa; Cho, Seung Woo; Mumbach, Maxwell R; Carter, Ava C; Kasowski, Maya; Orloff, Lisa A; Risca, Viviana I; Kundaje, Anshul; Khavari, Paul A; Montine, Thomas J; Greenleaf, William J; Chang, Howard Y

    2017-10-01

    We present Omni-ATAC, an improved ATAC-seq protocol for chromatin accessibility profiling that works across multiple applications with substantial improvement of signal-to-background ratio and information content. The Omni-ATAC protocol generates chromatin accessibility profiles from archival frozen tissue samples and 50-μm sections, revealing the activities of disease-associated DNA elements in distinct human brain structures. The Omni-ATAC protocol enables the interrogation of personal regulomes in tissue context and translational studies.

  18. High spatial and temporal resolution interrogation of fully distributed chirped fiber Bragg grating sensors

    OpenAIRE

    Ahmad, Eamonn J.; Wang, Chao; Feng, Dejun; Yan, Zhijun; Zhang, Lin

    2017-01-01

    A novel interrogation technique for fully distributed linearly chirped fiber Bragg grating (LCFBG) strain sensors with simultaneous high temporal and spatial resolution based on optical time-stretch frequency-domain reflectometry (OTS-FDR) is proposed and experimentally demonstrated. LCFBGs is a promising candidate for fully distributed sensors thanks to its longer grating length and broader reflection bandwidth compared to normal uniform FBGs. In the proposed system, two identical LCFBGs are...

  19. Recent advances in fast neutron radiography for cargo inspection

    International Nuclear Information System (INIS)

    Sowerby, B.D.; Tickner, J.R.

    2007-01-01

    Fast neutron radiography techniques are attractive for screening cargo for contraband such as narcotics and explosives. Neutrons have the required penetration, they interact with matter in a manner complementary to X-rays and they can be used to determine elemental composition. Compared to neutron interrogation techniques that measure secondary radiation (neutron or gamma-rays), neutron radiography systems are much more efficient and rapid and they are much more amenable to imaging. However, for neutron techniques to be successfully applied to cargo screening, they must demonstrate significant advantages over well-established X-ray techniques. This paper reviews recent developments and applications of fast neutron radiography for cargo inspection. These developments include a fast neutron and gamma-ray radiography system that utilizes a 14 MeV neutron generator as well as fast neutron resonance radiography systems that use variable energy quasi-monoenergetic neutrons and pulsed broad energy neutron beams. These systems will be discussed and compared with particular emphasis on user requirements, sources, detector systems, imaging ability and performance

  20. A Web Architecture to Geographically Interrogate CHIRPS Rainfall and eMODIS NDVI for Land Use Change

    Science.gov (United States)

    Burks, Jason E.; Limaye, Ashutosh

    2014-01-01

    Monitoring of rainfall and vegetation over the continent of Africa is important for assessing the status of crop health and agriculture, along with long-term changes in land use change. These issues can be addressed through examination of long-term precipitation (rainfall) data sets and remote sensing of land surface vegetation and land use types. Two products have been used previously to address these goals: the Climate Hazard Group Infrared Precipitation with Stations (CHIRPS) rainfall data, and multi-day composites of Normalized Difference Vegetation Index (NDVI) from the USGS eMODIS product. Combined, these are very large data sets that require unique tools and architecture to facilitate a variety of data analysis methods or data exploration by the end user community. To address these needs, a web-enabled system has been developed to allow end-users to interrogate CHIRPS rainfall and eMODIS NDVI data over the continent of Africa. The architecture allows end-users to use custom defined geometries, or the use of predefined political boundaries in their interrogation of the data. The massive amount of data interrogated by the system allows the end-users with only a web browser to extract vital information in order to investigate land use change and its causes. The system can be used to generate daily, monthly and yearly averages over a geographical area and range of dates of interest to the user. It also provides analysis of trends in precipitation or vegetation change for times of interest. The data provided back to the end-user is displayed in graphical form and can be exported for use in other, external tools. The development of this tool has significantly decreased the investment and requirements for end-users to use these two important datasets, while also allowing the flexibility to the end-user to limit the search to the area of interest.

  1. High speed and high resolution interrogation of a fiber Bragg grating sensor based on microwave photonic filtering and chirped microwave pulse compression.

    Science.gov (United States)

    Xu, Ou; Zhang, Jiejun; Yao, Jianping

    2016-11-01

    High speed and high resolution interrogation of a fiber Bragg grating (FBG) sensor based on microwave photonic filtering and chirped microwave pulse compression is proposed and experimentally demonstrated. In the proposed sensor, a broadband linearly chirped microwave waveform (LCMW) is applied to a single-passband microwave photonic filter (MPF) which is implemented based on phase modulation and phase modulation to intensity modulation conversion using a phase modulator (PM) and a phase-shifted FBG (PS-FBG). Since the center frequency of the MPF is a function of the central wavelength of the PS-FBG, when the PS-FBG experiences a strain or temperature change, the wavelength is shifted, which leads to the change in the center frequency of the MPF. At the output of the MPF, a filtered chirped waveform with the center frequency corresponding to the applied strain or temperature is obtained. By compressing the filtered LCMW in a digital signal processor, the resolution is improved. The proposed interrogation technique is experimentally demonstrated. The experimental results show that interrogation sensitivity and resolution as high as 1.25 ns/με and 0.8 με are achieved.

  2. A multiplex bead-based suspension array assay for interrogation of phylogenetically informative single nucleotide polymorphisms for Bacillus anthracis

    DEFF Research Database (Denmark)

    Thierry, Simon; Hamidjaja, Raditijo A.; Girault, Guillaume

    2013-01-01

    been modified and adapted for simultaneous interrogation of 13 biallelic canonical SNPs in a 13-plex assay. Changes made to the originally published method include the design of allele-specific dual-priming-oligonucleotides (DPOs) as competing detection probes (MOLigo probes) and use of asymmetric PCR...

  3. Psychologists abandon the Nuremberg ethic: concerns for detainee interrogations.

    Science.gov (United States)

    Pope, Kenneth S; Gutheil, Thomas G

    2009-01-01

    In the aftermath of 9-11, the American Psychological Association, one of the largest U.S. health professions, changed its ethics code so that it now runs counter to the Nuremberg Ethic. This historic post-9-11 change allows psychologists to set aside their ethical responsibilities whenever they are in irreconcilable conflict with military orders, governmental regulations, national and local laws, and other forms of governing legal authority. This article discusses the history, wording, rationale, and implications of the ethical standard that U.S. psychologists adopted 7 years ago, particularly in light of concerns over health care professionals' involvement in detainee interrogations and the controversy over psychologists' prominent involvement in settings like the Guantánamo Bay Detainment Camp and the Abu Ghraib prison. It discusses possible approaches to the complex dilemmas arising when ethical responsibilities conflict with laws, regulations, or other governing legal authority.

  4. The Department of Energy's safeguards and security technology development program

    International Nuclear Information System (INIS)

    Smith, G.D.; Pocratsky, C.A.

    1995-01-01

    The US DOE has had a program that develops technologies to protect sensitive nuclear weapons facilities for more than thirty years. The mission of the program is overwhelmingly diverse, as it must be to protect an array of assets such as nuclear weapons, special nuclear material in various forms, components of nuclear weapons, and classified nuclear weapons design information. Considering that the nuclear weapons complex consists of dozens of facilities that are scattered all over the US, the technology development mission is very challenging. Complicating matters further is the ever uncertain future of the DOE. Some examples of dramatic Departmental mission changes that directly impact their security technology development program are given. A few development efforts are highlighted as examples of efforts currently being sponsored. They are: automated sensor testing devices to help reduce the requirement for personnel to enter vaults containing highly radioactive nuclear materials; a vehicle inspection portal to screen vehicles for hidden passengers, nuclear material, explosives, and other contraband; non-lead and short-range ammunition as an environmentally safe alternative to lead ammunition; a complex-wide visitor access control system to allow all DOE employees to travel to all sites with a commonly recognized credential; automated nuclear material monitoring technologies to provide assurance that material in storage has not been tampered with; laser radar as a potential solution to early warning deficiencies throughout the Department; performance testing standards for many security products to include an automated and consistent standard for assessing the quality of video; low temperature pyrotechnic smoke as a possible adversary delay mechanism; modular vaults to provide temporary protection for nuclear material during D and D activities, and a protection approach for restricted passage areas such as the volume above a tiled ceiling or within a crawl space

  5. Dynamic Sensor Interrogation Using Wavelength-Swept Laser with a Polygon-Scanner-Based Wavelength Filter

    Science.gov (United States)

    Kwon, Yong Seok; Ko, Myeong Ock; Jung, Mi Sun; Park, Ik Gon; Kim, Namje; Han, Sang-Pil; Ryu, Han-Cheol; Park, Kyung Hyun; Jeon, Min Yong

    2013-01-01

    We report a high-speed (∼2 kHz) dynamic multiplexed fiber Bragg grating (FBG) sensor interrogation using a wavelength-swept laser (WSL) with a polygon-scanner-based wavelength filter. The scanning frequency of the WSL is 18 kHz, and the 10 dB scanning bandwidth is more than 90 nm around a center wavelength of 1,540 nm. The output from the WSL is coupled into the multiplexed FBG array, which consists of five FBGs. The reflected Bragg wavelengths of the FBGs are 1,532.02 nm, 1,537.84 nm, 1,543.48 nm, 1,547.98 nm, and 1,553.06 nm, respectively. A dynamic periodic strain ranging from 500 Hz to 2 kHz is applied to one of the multiplexed FBGs, which is fixed on the stage of the piezoelectric transducer stack. Good dynamic performance of the FBGs and recording of their fast Fourier transform spectra have been successfully achieved with a measuring speed of 18 kHz. The signal-to-noise ratio and the bandwidth over the whole frequency span are determined to be more than 30 dB and around 10 Hz, respectively. We successfully obtained a real-time measurement of the abrupt change of the periodic strain. The dynamic FBG sensor interrogation system can be read out with a WSL for high-speed and high-sensitivity real-time measurement. PMID:23899934

  6. The ethics of interrogation and the American Psychological Association: A critique of policy and process

    Directory of Open Access Journals (Sweden)

    Davis Martha

    2008-01-01

    Full Text Available Abstract The Psychological Ethics and National Security (PENS task force was assembled by the American Psychological Association (APA to guide policy on the role of psychologists in interrogations at foreign detention centers for the purpose of U.S. national security. The task force met briefly in 2005, and its report was quickly accepted by the APA Board of Directors and deemed consistent with the APA Ethics Code by the APA Ethics Committee. This rapid acceptance was unusual for a number of reasons but primarily because of the APA's long-standing tradition of taking great care in developing ethical policies that protected anyone who might be impacted by the work of psychologists. Many psychological and non-governmental organizations (NGOs, as well as reputable journalists, believed the risk of harm associated with psychologist participation in interrogations at these detention centers was not adequately addressed by the report. The present critique analyzes the assumptions of the PENS report and its interpretations of the APA Ethics Code. We demonstrate that it presents only one (and not particularly representative side of a complex set of ethical issues. We conclude with a discussion of more appropriate psychological contributions to national security and world peace that better respect and preserve human rights.

  7. The ethics of interrogation and the American Psychological Association: a critique of policy and process.

    Science.gov (United States)

    Olson, Brad; Soldz, Stephen; Davis, Martha

    2008-01-29

    The Psychological Ethics and National Security (PENS) task force was assembled by the American Psychological Association (APA) to guide policy on the role of psychologists in interrogations at foreign detention centers for the purpose of U.S. national security. The task force met briefly in 2005, and its report was quickly accepted by the APA Board of Directors and deemed consistent with the APA Ethics Code by the APA Ethics Committee. This rapid acceptance was unusual for a number of reasons but primarily because of the APA's long-standing tradition of taking great care in developing ethical policies that protected anyone who might be impacted by the work of psychologists. Many psychological and non-governmental organizations (NGOs), as well as reputable journalists, believed the risk of harm associated with psychologist participation in interrogations at these detention centers was not adequately addressed by the report. The present critique analyzes the assumptions of the PENS report and its interpretations of the APA Ethics Code. We demonstrate that it presents only one (and not particularly representative) side of a complex set of ethical issues. We conclude with a discussion of more appropriate psychological contributions to national security and world peace that better respect and preserve human rights.

  8. Radioactive waste package assay facility. Volume 2. Investigation of active neutron and active gamma interrogation

    International Nuclear Information System (INIS)

    Bailey, M.; Bunce, L.J.; Findlay, D.J.S.; Jolly, J.E.; Parsons, T.V.; Sene, M.R.; Swinhoe, M.T.

    1992-01-01

    Volume 2 of this report describes the theoretical and experimental work carried out at Harwell on active neutron and active gamma interrogation of 500 litre cemented intermediate level waste drums. The design of a suitable neutron generating target in conjunction with a LINAC was established. Following theoretical predictions of likely neutron responses, an experimental assay assembly was built. Responses were measured for simulated drums of ILW, based on CAGR, Magnox and PCM wastes. Good correlations were established between quantities of 235 -U, nat -U and D 2 O contained in the drums, and the neutron signals. Expected sensitivities are -1g of fissile actinide and -100g of total actinide. A measure of spatial distribution is obtainable. The neutron time spectra obtained during neutron interrogation were more complex than expected, and more analysis is needed. Another area of discrepancy is the difference between predicted and measured thermal neutron flux in the drum. Clusters of small 3 He proportional counters were found to be much superior for fast neutron detection than larger diameter counters. It is necessary to ensure constancy of electron beam position relative to target(s) and drum, and prudent to measure the target neutron or gamma output as appropriate. 59 refs., 77 figs., 11 tabs

  9. "What Exactly Is a Black?": Interrogating the Reality of Race in Jean Genet's The Blacks

    Directory of Open Access Journals (Sweden)

    Debby Thompson

    2002-06-01

    Full Text Available On the dedication page of The Blacks , Genet writes "One evening an actor asked me to write a play for an all-black cast. But what exactly is a black? First of all, what's his color?" Prefiguring major issues and paradoxes of African American cultural studies today, The Blacks insists on the very real ways in which the black/white racial binary, like the very concept of race itself, is lived and socially enforced, and at the same time argues that the binary is ultimately a fiction, made real through performative reification. Genet's "clown show," ambiguously reversing the blackface minstrelsy tradition, dramatizes how racial identity can become internalized and naturalized through cultural myths of interracial rape and colonialist narratives of a "heart of darkness," an imaginary site from which "black essence" arises. These racist performance traditions and narratives are so powerful and resilient that attempts to protest them become subtle and unwitting ways of re-creating them. The Blacks' parody of the minstrel tradition to interrogate all racial identity is so permanently suspended in a dialectic of both reinforcing the black/white binary and invalidating it, that the play's strategies present vital paradigms for the study of other and diverse interrogations of racial ontologies.

  10. Precision Medicine for Acute Kidney Injury (AKI): Redefining AKI by Agnostic Kidney Tissue Interrogation and Genetics.

    Science.gov (United States)

    Kiryluk, Krzysztof; Bomback, Andrew S; Cheng, Yim-Ling; Xu, Katherine; Camara, Pablo G; Rabadan, Raul; Sims, Peter A; Barasch, Jonathan

    2018-01-01

    Acute kidney injury (AKI) currently is diagnosed by a temporal trend of a single blood analyte: serum creatinine. This measurement is neither sensitive nor specific to kidney injury or its protean forms. Newer biomarkers, neutrophil gelatinase-associated lipocalin (NGAL, Lipocalin 2, Siderocalin), or kidney injury molecule-1 (KIM-1, Hepatitis A Virus Cellular Receptor 1), accelerate the diagnosis of AKI as well as prospectively distinguish rapidly reversible from prolonged causes of serum creatinine increase. Nonetheless, these biomarkers lack the capacity to subfractionate AKI further (eg, sepsis versus ischemia versus nephrotoxicity from medications, enzymes, or metals) or inform us about the primary and secondary sites of injury. It also is unknown whether all nephrons are injured in AKI, whether all cells in a nephron are affected, and whether injury responses can be stimulus-specific or cell type-specific or both. In this review, we summarize fully agnostic tissue interrogation approaches that may help to redefine AKI in cellular and molecular terms, including single-cell and single-nuclei RNA sequencing technology. These approaches will empower a shift in the current paradigm of AKI diagnosis, classification, and staging, and provide the renal community with a significant advance toward precision medicine in the analysis AKI. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Additively Manufactured IN718 Components with Wirelessly Powered and Interrogated Embedded Sensing

    Energy Technology Data Exchange (ETDEWEB)

    Attridge, Paul [United Technologies Research Center, East Hartford, CT (United States); Bajekal, Sanjay [United Technologies Research Center, East Hartford, CT (United States); Klecka, Michael [United Technologies Research Center, East Hartford, CT (United States); Wu, Xin [United Technologies Research Center, East Hartford, CT (United States); Savulak, Steve [United Technologies Research Center, East Hartford, CT (United States); Viens, Dan [United Technologies Research Center, East Hartford, CT (United States); Carey, Michael [United Technologies Research Center, East Hartford, CT (United States); Miano, John [United Technologies Research Center, East Hartford, CT (United States); Rioux, William [United Technologies Research Center, East Hartford, CT (United States); Zacchio, Joseph [United Technologies Research Center, East Hartford, CT (United States); Dunst, Richard [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Straub, Doug [National Energy Technology Lab. (NETL), Pittsburgh, PA, (United States); Mantese, Joseph [United Technologies Research Center, East Hartford, CT (United States)

    2017-07-14

    A methodology is described for embedding commercial-off-the-shelf sensors together with wireless communication and power circuit elements using direct laser metal sintered additively manufactured components. Physics based models of the additive manufacturing processes and sensor/wireless level performance models guided the design and embedment processes. A combination of cold spray deposition and laser engineered net shaping was used to fashion the transmitter/receiving elements and embed the sensors, thereby providing environmental protection and component robustness/survivability for harsh conditions. By design, this complement of analog and digital sensors were wirelessly powered and interrogated using a health and utilization monitoring system; enabling real-time, in situ prognostics and diagnostics.

  12. Amygdala-enriched genes identified by microarray technology are restricted to specific amygdaloid subnuclei

    OpenAIRE

    Zirlinger, M.; Kreiman, Gabriel; Anderson, D. J.

    2001-01-01

    Microarray technology represents a potentially powerful method for identifying cell type- and regionally restricted genes expressed in the brain. Here we have combined a microarray analysis of differential gene expression among five selected brain regions, including the amygdala, cerebellum, hippocampus, olfactory bulb, and periaqueductal gray, with in situ hybridization. On average, 0.3% of the 34,000 genes interrogated were highly enriched in each of the five regions...

  13. Screening of Maritime Containers to Intercept Weapons of Mass Destruction

    International Nuclear Information System (INIS)

    Manatt, D R; Sleaford, B; Schaffer, T; Accatino, M R; Slaughter, D; Mauger, J; Newmark, R; Prussin, S; Luke, J; Frank, M; Bernstein, A; Alford, O; Mattesich, G; Stengel, J; Hall, J; Descalle, M A; Wolford, J; Hall, H; Loshak, A; Sale, K; Trombino, D; Dougan, A D; Pohl, B; Dietrich, D; Weirup, D; Walling, R; Rowland, M; Johnson, D; Hagmann, C; Hankins, D

    2004-01-01

    The goal of our research was to address the problem of detection of weapons of mass destruction (WMD) materials within containers in common use on commercial cargo trafficking. LLNL has created an experimental test bed for researching potential solutions using (among other techniques) active interrogation with neutrons. Experiments and computational modeling were used to determine the effectiveness of the technique. Chemical weapons materials and high explosives can be detected using neutron activation and simple geometries with little or no intervening material. However in a loaded container there will be nuisance alarms from conflicting signatures resulting from the presence of material between the target and the detector (and the interrogation source). Identifying some elements may require long counting times because of the increased background. We performed some simple signature measurements and simulations of gamma-ray spectra from several chemical simulants. We identified areas where the nuclear data was inadequate to perform detailed computations. We concentrated on the detection of SNM in cargo containers, which will be emphasized here. The goal of the work reported here is to develop a concept for an active neutron interrogation system that can detect small targets of SNM contraband in cargo containers, roughly 5 kg HEU or 1 kg Pu, even when well shielded by a thick cargo. It is essential that the concept be reliable and have low false-positive and false-negative error rates. It also must be rapid to avoid interruption of commerce, completing the analysis in minutes. A potentially viable concept for cargo interrogation has been developed and its components have been evaluated experimentally. A new radiation signature unique to SNM has been identified that utilizes high-energy, fission-product gamma rays. That signature due to γ-radiation in the range 3-6 MeV is distinct from normal background radioactivity that does not extend above 2.6 MeV. It's short

  14. Simultaneous photon and neutron interrogation using an electron accelerator in order to quantify actinides in encapsulated radioactive wastes; Double interrogation simultanee neutrons et photons utilisant un accelerateur d'electrons pour la caracterisation separee des actinides dans les dechets radioactifs enrobes

    Energy Technology Data Exchange (ETDEWEB)

    Jallu, F

    1999-09-24

    Measuring out alpha emitters, such as ({sup 234,235,236,238}U {sup 238,239,240,242,}2{sup 44P}u, {sup 237}Np {sup 241,243}Am...), in solid radioactive waste, allows us to quantify the alpha activity in a drum and then to classify it. The SIMPHONIE (SIMultaneous PHOton and Neutron Interrogation Experiment) method, developed in this Ph.D. work, combines both the Active Neutron Interrogation and the Induced Photofission Interrogation techniques simultaneously. Its purpose is to quantify in only one measurement, fissile ({sup 235}U, {sup 239,241}Pu...) and fertile ({sup 236,238}U, {sup 238,240}Pu...) elements separately. In the first chapter of this Ph.D. report, we present the principle of the Radioactive Waste Management in France. The second chapter deals with the physical properties of neutron fission and of photofission. These two nuclear reactions are the basis of the SIMPHONIE method. Moreover, one of our purposes was to develop the ELEPHANT (ELEctron PHoton And Neutron Transport) code in view to simulate the electron, photon and neutron transport, including the ({gamma}, n), ({gamma}, 2n) and ({gamma}, f) photonuclear reactions that are not taken into account in the MCNP4 (Monte Carlo N-Particle) code. The simulation codes developed and used in this work are detailed in the third chapter. Finally, the fourth chapter gives the experimental results of SIMPHONIE obtained by using the DGA/ETCA electron linear accelerators located at Arcueil, France. Fissile ({sup 235}U, {sup 239}Pu) and fertile ({sup 238}U) samples were studied. Furthermore, comparisons between experimental results and calculated data of photoneutron production in tungsten, copper, praseodymium and beryllium by using an electron LINear Accelerator (LINAC) are given. This allows us to evaluate the validity degree of the ELEPHANT code, and finally the feasibility of the SIMPHONIE method. (author)

  15. Klausimų forma ir funkcijos lietuvių ir rusų vaikiškojoje kalboje. Forms and functions of interrogatives in Lithuanian and Russian motherese

    Directory of Open Access Journals (Sweden)

    Ingrida Balčiūnienė

    2011-01-01

    Full Text Available The paper focuses on adult interrogatives, which appear to be among the most frequent and typical ways of communicating with young children. The main objective of the investigation is to identify and compare the variety and distribution of interrogatives in Lithuanian and Russian motherese. The analysis is based on the data of a longitudinal observation of a Lithuanian girl Monika (2;0–2;8 and a Russian boy Vanja (2;0–2;8. The transcribed corpus of conversations between children and their parents was annotated for a multipurpose automatic linguistic analysis using tools of the program CHILDES (Child Language Data Exchange System, MacWhinney 1991. Despite several differences (the general number of questions, and the dominant forms of indirect correction, it can be stated that interrogatives in both Russian and Lithuanian motherese are generally used for the same conversational strategies; the communicative strategies in the two languages seem to be similar or even identical. Moreover, during the observation period, the conversational strategies in both Russian and Lithuanian motherese developed in a similar way. This calls for a general conclusion that a correlation between parental conversational strategy and the type of language can be identified.

  16. AN/UPX-41(C) IFF Interrogator Compatibility with the National Airspace System : Top-Level Test Plan Chesapeake Fixed-Base Experiment

    Science.gov (United States)

    2015-08-04

    In 2012, the Navy requested spectrum certification for the shipboard AN/UPX-41(C) Digital Interrogator System, Software Version 5.5 with Mode 5. : Current operating conditions for the Navys AN/UPX-41(C) are the same as restrictions imposed on the ...

  17. Methods and systems for Raman and optical cross-interrogation in flow-through silicon membranes

    Science.gov (United States)

    Bond, Tiziana C.; Letant, Sonia E.

    2014-09-09

    Cross-interrogating photonic detection systems and methods are shown. A flow through photonic crystal membrane with a surface enhanced Raman scattering (SERS) substrate is provided with pores which are distributed along multiple regions. The pores of one region have walls to which a first type of target specific anchor can be attached, while pores of another region have walls to which a second type of target specific anchor can be attached. An optical arrangement out-of-plane to the SERS substrate is also provided for enhanced sensitivity and identification of target organisms.

  18. Systematic Functional Interrogation of Rare Cancer Variants Identifies Oncogenic Alleles | Office of Cancer Genomics

    Science.gov (United States)

    Cancer genome characterization efforts now provide an initial view of the somatic alterations in primary tumors. However, most point mutations occur at low frequency, and the function of these alleles remains undefined. We have developed a scalable systematic approach to interrogate the function of cancer-associated gene variants. We subjected 474 mutant alleles curated from 5,338 tumors to pooled in vivo tumor formation assays and gene expression profiling. We identified 12 transforming alleles, including two in genes (PIK3CB, POT1) that have not been shown to be tumorigenic.

  19. Proteomic Technologies for the Study of Osteosarcoma

    Directory of Open Access Journals (Sweden)

    Stephanie D. Byrum

    2012-01-01

    Full Text Available Osteosarcoma is the most common primary bone cancer of children and is established during stages of rapid bone growth. The disease is a consequence of immature osteoblast differentiation, which gives way to a rapidly synthesized incompletely mineralized and disorganized bone matrix. The mechanism of osteosarcoma tumorogenesis is poorly understood, and few proteomic studies have been used to interrogate the disease thus far. Accordingly, these studies have identified proteins that have been known to be associated with other malignancies, rather than being osteosarcoma specific. In this paper, we focus on the growing list of available state-of-the-art proteomic technologies and their specific application to the discovery of novel osteosarcoma diagnostic and therapeutic targets. The current signaling markers/pathways associated with primary and metastatic osteosarcoma that have been identified by early-stage proteomic technologies thus far are also described.

  20. Combined Photoneutron And X Ray Interrogation Of Containers For Nuclear Materials

    Science.gov (United States)

    Gozani, Tsahi; Shaw, Timothy; King, Michael J.; Stevenson, John; Elsalim, Mashal; Brown, Craig; Condron, Cathie

    2011-06-01

    Effective cargo inspection systems for nuclear material detection require good penetration by the interrogating radiation, generation of a sufficient number of fissions, and strong and penetrating detection signatures. Inspection systems need also to be sensitive over a wide range of cargo types and densities encountered in daily commerce. Thus they need to be effective with highly hydrogenous cargo, where neutron attenuation is a major limitation, as well as with dense metallic cargo, where x-ray penetration is low. A system that interrogates cargo with both neutrons and x-rays can, in principle, achieve high performance over the widest range of cargos. Moreover, utilizing strong prompt-neutron (˜3 per fission) and delayed-gamma ray (˜7 per fission) signatures further strengthens the detection sensitivity across all cargo types. The complementary nature of x-rays and neutrons, used as both probing radiation and detection signatures, alleviates the need to employ exceedingly strong sources, which would otherwise be required to achieve adequate performance across all cargo types, if only one type of radiation probe were employed. A system based on the above principles, employing a commercially-available 9 MV linac was developed and designed. Neutrons are produced simultaneously with x-rays by the photonuclear interaction of the x-ray beam with a suitable converter. A total neutron yield on the order of 1011 n/s is achieved with an average electron beam current of 100 μA. If fissionable material is present, fissions are produced both by the high-energy x-ray beam and by the photoneutrons. Photofission and neutron fission dominate in hydrogenous and metallic cargos, respectively. Neutron-capture gamma rays provide information on the cargo composition. The prompt neutrons resulting from fission are detected by two independent detector systems: by very efficient Differential Die Away Analysis (DDAA) detectors, and by direct detection of neutrons with energies higher

  1. Volume 7, No. 2 ISSN-2077-3420 December 2015 Cross-Border ...

    African Journals Online (AJOL)

    Maru Shete

    2015-12-02

    Dec 2, 2015 ... contraband trade across the main route from Moyale (border town .... revenue and customs sector, and planned to increase the share of tax ... and social causes of cross border contraband trade have been ... youths are turning towards CBCT as a means of sedentary life and ..... However, this vicious circle.

  2. The ethics of interrogation and the American Psychological Association: A critique of policy and process

    OpenAIRE

    Olson, Brad; Soldz, Stephen; Davis, Martha

    2008-01-01

    Abstract The Psychological Ethics and National Security (PENS) task force was assembled by the American Psychological Association (APA) to guide policy on the role of psychologists in interrogations at foreign detention centers for the purpose of U.S. national security. The task force met briefly in 2005, and its report was quickly accepted by the APA Board of Directors and deemed consistent with the APA Ethics Code by the APA Ethics Committee. This rapid acceptance was unusual for a number o...

  3. Using cooperatives ontologies for the customization of hybrid mediator interrogation process

    Directory of Open Access Journals (Sweden)

    Cherrat LOUBNA

    2011-06-01

    Full Text Available The explosion of information sources accessible via the Web created the need for mediation tools between users and heterogeneous information sources on the Web. However, the interface design of these mediators, with taking into account the wide variety of skills and knowledge of users, and the need for them to share their preferences, requires systems able to guide the user through the interrogation process. In this paper, we try to raise this challenge  by proposing, on one hand, the use of a cooperative ontology’s models, which adapt with the evolution of user’s profiles and the dynamic change of integrated sources, and secondly ensure sharing the knowledge between users which will facilitate analysis of information and improve the data quality research process in space  and time.

  4. Discrimination Using the Geonics EM63 in a Cued Interrogation Mode at Fort McClellan, AL

    Science.gov (United States)

    2009-03-01

    vectors of the nine items measured at the Ashland test plot: (a) Pasion - Oldenburg k1 versus k2; (b) Ratio of the primary polarization tensor at the 10th...discrimination potential of the Geonics EM63 at Fort McClellan, Alabama (AL) when deployed in a cued interrogation mode. Pasion - Oldenburg polarization...scrap metal, shrapnel and geology (e.g. Hart et al., 2001; Collins et al., 2001; Pasion & Oldenburg, 2001; Zhang et al., 2003a, 2003b; Billings

  5. Integrated Approaches for Genome-wide Interrogation of the Druggable Non-olfactory G Protein-coupled Receptor Superfamily.

    Science.gov (United States)

    Roth, Bryan L; Kroeze, Wesley K

    2015-08-07

    G-protein-coupled receptors (GPCRs) are frequent and fruitful targets for drug discovery and development, as well as being off-targets for the side effects of a variety of medications. Much of the druggable non-olfactory human GPCR-ome remains under-interrogated, and we present here various approaches that we and others have used to shine light into these previously dark corners of the human genome. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.

  6. Interrogating resilience in health systems development.

    Science.gov (United States)

    van de Pas, Remco; Ashour, Majdi; Kapilashrami, Anuj; Fustukian, Suzanne

    2017-11-01

    The Fourth Global Symposium on Health Systems Research was themed around 'Resilient and responsive health systems for a changing world.' This commentary is the outcome of a panel discussion at the symposium in which the resilience discourse and its use in health systems development was critically interrogated. The 2014-15 Ebola outbreak in West-Africa added momentum for the wider adoption of resilient health systems as a crucial element to prepare for and effectively respond to crisis. The growing salience of resilience in development and health systems debates can be attributed in part to development actors and philanthropies such as the Rockefeller Foundation. Three concerns regarding the application of resilience to health systems development are discussed: (1) the resilience narrative overrules certain democratic procedures and priority setting in public health agendas by 'claiming' an exceptional policy space; (2) resilience compels accepting and maintaining the status quo and excludes alternative imaginations of just and equitable health systems including the socio-political struggles required to attain those; and (3) an empirical case study from Gaza makes the case that resilience and vulnerability are symbiotic with each other rather than providing a solution for developing a strong health system. In conclusion, if the normative aim of health policies is to build sustainable, universally accessible, health systems then resilience is not the answer. The current threats that health systems face demand us to imagine beyond and explore possibilities for global solidarity and justice in health. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. Multiplicity Analysis during Photon Interrogation of Fissionable Material

    International Nuclear Information System (INIS)

    Clarke, Shaun D.; Pozzi, Sara A.; Padovani, Enrico; Downar, Thomas J.

    2007-01-01

    Simulation of multiplicity distributions with the Monte Carlo method is difficult because each history is treated individually. In order to accurately model the multiplicity distribution, the intensity and time width of the interrogation pulse must be incorporated into the calculation. This behavior dictates how many photons arrive at the target essentially simultaneously. In order to model the pulse width correctly, a Monte Carlo code system consisting of modified versions of the codes MCNPX and MCNP-PoliMi has been developed in conjunction with a post-processing algorithm to operate on the MCNP-PoliMi output file. The purpose of this subroutine is to assemble the interactions into groups corresponding to the number of interactions which would occur during a given pulse. The resulting multiplicity distributions appear more realistic and capture the higher-order multiplets which are a product of multiple reactions occurring during a single accelerator pulse. Plans are underway to gather relevant experimental data to verify and validate the methodology developed and presented here. This capability will enable the simulation of a large number of materials and detector geometries. Analysis of this information will determine the feasibility of using multiplicity distributions as an identification tool for special nuclear material.

  8. Quench detection for high temperature superconductor magnets: a novel technique based on Rayleigh-backscattering interrogated optical fibers

    International Nuclear Information System (INIS)

    Scurti, F; Ishmael, S; Schwartz, J; Flanagan, G

    2016-01-01

    High temperature superconducting materials are the only option for the generation of magnetic fields exceeding 25 T and for magnets operating over a broad range of temperature and magnetic field for power applications. One remaining obstacle for the implementation of high temperature superconductors magnets into systems, however, is the inability to rapidly detect a quench. In this letter we present a novel quench detection technique that has been investigated experimentally. Optical fibers are co-wound into two small Bi 2 Sr 2 Ca 2 Cu 3 O 10+x superconducting coils and interrogated by Rayleigh-backscattering. Two different configurations are used, one with the fiber atop the conductor and the other with the fiber located as turn-to-turn insulation. Each coil is also instrumented with voltage taps (VTs) and thermocouples for comparison during heater-induced quenches. The results show that Rayleigh-backscattering interrogated optical fibers (RIOF) have significant advantages over traditional techniques, including very high spatial resolution and the ability to detect a hot-spot well before the peak local temperature exceeds the current sharing temperature. Thus, RIOF quench detection is intrinsically faster than VTs, and this intrinsic advantage is greater as the coil size and/or current margin increases. (letter)

  9. Taxation, smuggling and demand for cigarettes in Canada: evidence from time-series data.

    Science.gov (United States)

    Galbraith, J W; Kaiserman, M

    1997-06-01

    This study analyzes Canadian cigarette consumption and taxation between 1980 and 1994, a period in which there have been large price rises and declines, and a dramatic increase in the consumption of contraband tobacco products. We examine elasticities of legal cigarette sales and total sales (including contraband) with respect to the price of legal cigarettes and various other factors. The growth of the contraband market since 1987 appears to have created two classes of cigarette--taxed and untaxed--with responses to changes in the legal price that are respectively higher, and lower, than was previously the case. The sensitivity of total cigarette sales to the taxation instrument is much lower than it would appear from sales of taxed cigarettes alone.

  10. Comportamiento al margen de la ley: contrabando y sociedad en Buenos Aires en el siglo XVII *

    Directory of Open Access Journals (Sweden)

    Macarena Perusset Veras

    2007-06-01

    Full Text Available Illicit Behavior: Smuggling and Society in Seventeenth-Century Buenos Aires ABSTRACTIn this work we look into the origins of illegal commerce to analyze how contraband was conducted in the port of Buenos Aires in the early seventeenth-century. To do this, we will analyze the political and economic context in which contraband arose and gained importance in order to reflect whether this economic practice -conducted by government officials, vecinos (official residents and settlers of the port of Buenos Aires- can be considered corrupt in the context of the period studied. We will situate the behavior of these social actors within an intertwined complex of political beliefs and ideologies, and conjunctures, to explain how a practice like colonial-era contraband has multiple, tightly related causes.

  11. Rapid-rate nonsustained ventricular tachycardia found on implantable cardioverter-defibrillator interrogation: relationship to outcomes in the SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial).

    Science.gov (United States)

    Chen, Jay; Johnson, George; Hellkamp, Anne S; Anderson, Jill; Mark, Daniel B; Lee, Kerry L; Bardy, Gust H; Poole, Jeanne E

    2013-05-28

    The aim of this study was to examine rapid-rate nonsustained ventricular tachycardia (RR-NSVT) during routine implantable cardioverter-defibrillator (ICD) evaluation in patients with heart failure and its relationship to outcomes. The clinical implications of RR-NSVT identified during routine ICD interrogation are unclear. In this study, the occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT (Sudden Cardiac Death in Heart Failure Trial) were examined. The 811 patients who received ICDs in SCD-HeFT constituted the study population. The occurrence of RR-NSVT and its association with ICD shocks and mortality in SCD-HeFT were examined. RR-NSVT was documented on ICD interrogation in 186 of 811 patients (22.9%). The mean duration of RR-NSVT was 26.4 ± 9.1 beats (7.5 ± 2.6 s), with a mean cycle length of 259 ± 32 ms. Polymorphic RR-NSVT accounted for 56% of episodes. Compared with patients without RR-NSVT, those with RR-NSVT were less likely to be taking beta-blockers, statins, or aspirin at enrollment. After adjusting for other known predictors of mortality in SCD-HeFT, RR-NSVT was independently associated with appropriate ICD shocks (hazard ratio: 4.25; 95% confidence interval: 2.94 to 6.14; p interrogation should be considered an important clinical event. RR-NSVT during ICD interrogation is associated with appropriate ICD shocks and all-cause mortality. The clinical evaluation of patients with RR-NSVT should include intensification of medical therapy, particularly beta-blockers, or other appropriate clinical interventions. (Sudden Cardiac Death in Heart Failure Trial [SCD-HeFT]; NCT00000609). Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Fissile and fertile nuclear material measurements using a new differential die-away self-interrogation technique

    International Nuclear Information System (INIS)

    Menlove, H.O.; Menlove, S.H.; Tobin, S.J.

    2009-01-01

    This paper presents a new technique for the measurement of fissile and fertile nuclear materials in spent fuel and plutonium-laden materials such as mixed oxide (MOX) fuel. The technique, called differential die-away self-interrogation, is similar to traditional differential die-away analysis, but it does not require a pulsed neutron generator or pulsed beam accelerator, and it can measure the fertile mass in addition to the fissile mass. The new method uses the spontaneous fission neutrons from 244 Cm in spent fuel and 240 Pu effective neutrons in MOX as the 'pulsed' neutron source, with an average of ∼2.7 neutrons per pulse. The time-correlated neutrons from the spontaneous fission and the subsequent induced fissions are analyzed as a function of time to determine the spontaneous fission rate, the induced fast-neutron fissions, and the induced thermal-neutron fissions. The fissile mass is determined from the induced thermal-neutron fissions that are produced by reflected thermal neutrons that originated from the spontaneous fission reaction. The sensitivity of the fissile mass measurement is enhanced by the use of two measurements, with and without a cadmium liner between the sample and a hydrogenous moderator that surrounds the sample. The fertile mass is determined from the multiplicity analysis of the neutrons detected soon after the initial triggering neutron is detected. The method obtains good sensitivity by the optimal design of two different neutron die-away regions: a short die-away for the neutron detector region and a longer die-away for the sample interrogation region.

  13. Enhanced sensitivity of surface plasmon resonance phase-interrogation biosensor by using oblique deposited silver nanorods.

    Science.gov (United States)

    Chung, Hung-Yi; Chen, Chih-Chia; Wu, Pin Chieh; Tseng, Ming Lun; Lin, Wen-Chi; Chen, Chih-Wei; Chiang, Hai-Pang

    2014-01-01

    Sensitivity of surface plasmon resonance phase-interrogation biosensor is demonstrated to be enhanced by oblique deposited silver nanorods. Silver nanorods are thermally deposited on silver nanothin film by oblique angle deposition (OAD). The length of the nanorods can be tuned by controlling the deposition parameters of thermal deposition. By measuring the phase difference between the p and s waves of surface plasmon resonance heterodyne interferometer with different wavelength of incident light, we have demonstrated that maximum sensitivity of glucose detection down to 7.1 × 10(-8) refractive index units could be achieved with optimal deposition parameters of silver nanorods.

  14. DNA interrogation by the CRISPR RNA-guided endonuclease Cas9.

    Science.gov (United States)

    Sternberg, Samuel H; Redding, Sy; Jinek, Martin; Greene, Eric C; Doudna, Jennifer A

    2014-03-06

    The clustered regularly interspaced short palindromic repeats (CRISPR)-associated enzyme Cas9 is an RNA-guided endonuclease that uses RNA-DNA base-pairing to target foreign DNA in bacteria. Cas9-guide RNA complexes are also effective genome engineering agents in animals and plants. Here we use single-molecule and bulk biochemical experiments to determine how Cas9-RNA interrogates DNA to find specific cleavage sites. We show that both binding and cleavage of DNA by Cas9-RNA require recognition of a short trinucleotide protospacer adjacent motif (PAM). Non-target DNA binding affinity scales with PAM density, and sequences fully complementary to the guide RNA but lacking a nearby PAM are ignored by Cas9-RNA. Competition assays provide evidence that DNA strand separation and RNA-DNA heteroduplex formation initiate at the PAM and proceed directionally towards the distal end of the target sequence. Furthermore, PAM interactions trigger Cas9 catalytic activity. These results reveal how Cas9 uses PAM recognition to quickly identify potential target sites while scanning large DNA molecules, and to regulate scission of double-stranded DNA.

  15. DNA interrogation by the CRISPR RNA-guided endonuclease Cas9

    Science.gov (United States)

    Sternberg, Samuel H.; Redding, Sy; Jinek, Martin; Greene, Eric C.; Doudna, Jennifer A.

    2014-03-01

    The clustered regularly interspaced short palindromic repeats (CRISPR)-associated enzyme Cas9 is an RNA-guided endonuclease that uses RNA-DNA base-pairing to target foreign DNA in bacteria. Cas9-guide RNA complexes are also effective genome engineering agents in animals and plants. Here we use single-molecule and bulk biochemical experiments to determine how Cas9-RNA interrogates DNA to find specific cleavage sites. We show that both binding and cleavage of DNA by Cas9-RNA require recognition of a short trinucleotide protospacer adjacent motif (PAM). Non-target DNA binding affinity scales with PAM density, and sequences fully complementary to the guide RNA but lacking a nearby PAM are ignored by Cas9-RNA. Competition assays provide evidence that DNA strand separation and RNA-DNA heteroduplex formation initiate at the PAM and proceed directionally towards the distal end of the target sequence. Furthermore, PAM interactions trigger Cas9 catalytic activity. These results reveal how Cas9 uses PAM recognition to quickly identify potential target sites while scanning large DNA molecules, and to regulate scission of double-stranded DNA.

  16. Two-step interrogation then recognition of DNA binding site by Integration Host Factor: an architectural DNA-bending protein.

    Science.gov (United States)

    Velmurugu, Yogambigai; Vivas, Paula; Connolly, Mitchell; Kuznetsov, Serguei V; Rice, Phoebe A; Ansari, Anjum

    2018-02-28

    The dynamics and mechanism of how site-specific DNA-bending proteins initially interrogate potential binding sites prior to recognition have remained elusive for most systems. Here we present these dynamics for Integration Host factor (IHF), a nucleoid-associated architectural protein, using a μs-resolved T-jump approach. Our studies show two distinct DNA-bending steps during site recognition by IHF. While the faster (∼100 μs) step is unaffected by changes in DNA or protein sequence that alter affinity by >100-fold, the slower (1-10 ms) step is accelerated ∼5-fold when mismatches are introduced at DNA sites that are sharply kinked in the specific complex. The amplitudes of the fast phase increase when the specific complex is destabilized and decrease with increasing [salt], which increases specificity. Taken together, these results indicate that the fast phase is non-specific DNA bending while the slow phase, which responds only to changes in DNA flexibility at the kink sites, is specific DNA kinking during site recognition. Notably, the timescales for the fast phase overlap with one-dimensional diffusion times measured for several proteins on DNA, suggesting that these dynamics reflect partial DNA bending during interrogation of potential binding sites by IHF as it scans DNA.

  17. Juveniles’ Right to Counsel During Police Interrogations: An Interdisciplinary Analysis of a Youth-Specific Approach, with a Particular Focus on the Netherlands

    NARCIS (Netherlands)

    T. Liefaard (Ton); Y. van den Brink (Yannick)

    2014-01-01

    markdownabstract__Abstract__ The right to counsel of juveniles at the stage of police interrogations has gained significant attention since the Salduz ruling of the European Court on Human Rights in 2008. The legislative and policy developments that have taken place since then and that are still

  18. Interrogating discourse: the application of Foucault's methodological discussion to specific inquiry.

    Science.gov (United States)

    Fadyl, Joanna K; Nicholls, David A; McPherson, Kathryn M

    2013-09-01

    Discourse analysis following the work of Michel Foucault has become a valuable methodology in the critical analysis of a broad range of topics relating to health. However, it can be a daunting task, in that there seems to be both a huge number of possible approaches to carrying out this type of project, and an abundance of different, often conflicting, opinions about what counts as 'Foucauldian'. This article takes the position that methodological design should be informed by ongoing discussion and applied as appropriate to a particular area of inquiry. The discussion given offers an interpretation and application of Foucault's methodological principles, integrating a reading of Foucault with applications of his work by other authors, showing how this is then applied to interrogate the practice of vocational rehabilitation. It is intended as a contribution to methodological discussion in this area, offering an interpretation of various methodological elements described by Foucault, alongside specific application of these aspects.

  19. Coupling Sensing Hardware with Data Interrogation Software for Structural Health Monitoring

    Directory of Open Access Journals (Sweden)

    Charles R. Farrar

    2006-01-01

    Full Text Available The process of implementing a damage detection strategy for aerospace, civil and mechanical engineering infrastructure is referred to as structural health monitoring (SHM. The authors' approach is to address the SHM problem in the context of a statistical pattern recognition paradigm. In this paradigm, the process can be broken down into four parts: (1 Operational Evaluation, (2 Data Acquisition and Cleansing, (3 Feature Extraction and Data Compression, and (4 Statistical Model Development for Feature Discrimination. These processes must be implemented through hardware or software and, in general, some combination of these two approaches will be used. This paper will discuss each portion of the SHM process with particular emphasis on the coupling of a general purpose data interrogation software package for structural health monitoring with a modular wireless sensing and processing platform. More specifically, this paper will address the need to take an integrated hardware/software approach to developing SHM solutions.

  20. Development of the QA/QC Procedures for a Neutron Interrogation System

    Energy Technology Data Exchange (ETDEWEB)

    Obhodas, Jasmina; Sudac, Davorin; Valkovic, Vladivoj [Ruder Boskovic Institute, 10000 Zagreb (Croatia)

    2015-07-01

    In order to perform QA/QC procedures for a system dedicated to the neutron interrogation of objects for the presence of threat materials one needs to perform measurements of reference materials (RM) having the same (or similar) atomic ratios as real materials. It is well known that explosives, drugs, and various other benign materials, contain chemical elements such as hydrogen, oxygen, carbon and nitrogen in distinctly different quantities. For example, a high carbon-to-oxygen ratio (C/O) is characteristic of drugs. Explosives can be differentiated by measurement of both C/O and nitrogen-to-oxygen (N/O) ratios. The C/N ratio of the chemical warfare agents, coupled with the measurement of elements such as fluorine and phosphorus, clearly differentiate them from the conventional explosives. Correlations between theoretical values and experimental results obtained in laboratory conditions for C/O and N/C ratios of simulants of hexogen (RDX), TNT, DLM2, TATP, cocaine, heroin, yperite, tetranitromethane, peroxide methylethyl-ketone, nitromethane and ethyleneglycol dinitrate are presented. (authors)

  1. "They're doing people a service"-qualitative study of smoking, smuggling, and social deprivation.

    Science.gov (United States)

    Wiltshire, S; Bancroft, A; Amos, A; Parry, O

    2001-07-28

    To examine the behaviour and attitudes related to smoking and contraband tobacco products among smokers in two socially deprived areas. Cross sectional study with qualitative semistructured interviews, augmented by smokers' day grid. Two areas of socioeconomic deprivation in Edinburgh. 50 male and 50 female smokers aged 25-40 years randomly selected from general practitioners' lists from two health centres, each located in an area of deprivation. Most smokers wanted to quit but felt unable to because of the importance of smoking in their daily routine and their addiction to nicotine. Strategies for maintaining consumption levels in the face of increasing cigarette prices and low income included purchasing contraband cigarettes and tobacco. Vendors were contacted through social networks, family, and friends as well as common knowledge of people and places, particularly pubs where contraband was available. Most users of contraband considered that smugglers were providing a valuable service. Purchasing contraband tobacco was viewed as rational in the face of material hardship. Many smokers criticised the government for its high tobacco taxation and the lack of local services to help them to stop smoking. Smokers in deprived areas perceive a lack of support to help them to stop smoking. Cigarette and tobacco smuggling is therefore viewed positively by low income smokers as a way of dealing with the increasing cost of cigarettes. Smokers in areas of deprivation may thus show little support for tackling smuggling until more action is taken to deal with the material and personal factors that make it difficult for them to quit.

  2. Where’s the Transformation? Unlocking the Potential of Technology-Enhanced Assessment

    Directory of Open Access Journals (Sweden)

    Trudy Sweeney

    2017-03-01

    Full Text Available This study provides insight into technology-enhanced assessment (TEA in diverse higher education contexts. The effectiveness of using technology for assessment in higher education is still equivocal, particularly in regard to evidence of improvements in student learning. This empirical research explores the affordances that technology offers to assessment for transforming student learning. A systematic literature review, guided by an analytic survey tool, was used to identify and interrogate recent scholarly articles published in 19 international journals. From a total of 1713 articles, 139 articles were identified as being focused on the use of technology for assessment. The analytic tool guided the rigorous exploration of the literature regarding the types of technology being used, the educational goal, the type of assessment, and the degree of “transformation” afforded by the technology. Results showed that, in the sample investigated, TEA is used most frequently for formative peer learning, as part of the task design and feedback stages of the assessment cycle, and that social media has been a major affordance for this. Results are discussed with a view to fostering a future culture of inquiry and scholarship around TEA in higher education.

  3. “They're doing people a service”—qualitative study of smoking, smuggling, and social deprivation

    Science.gov (United States)

    Wiltshire, Susan; Bancroft, Angus; Amos, Amanda; Parry, Odette

    2001-01-01

    Objectives To examine the behaviour and attitudes related to smoking and contraband tobacco products among smokers in two socially deprived areas. Design Cross sectional study with qualitative semistructured interviews, augmented by smokers' day grid. Setting Two areas of socioeconomic deprivation in Edinburgh. Participants 50 male and 50 female smokers aged 25-40 years randomly selected from general practitioners' lists from two health centres, each located in an area of deprivation. Results Most smokers wanted to quit but felt unable to because of the importance of smoking in their daily routine and their addiction to nicotine. Strategies for maintaining consumption levels in the face of increasing cigarette prices and low income included purchasing contraband cigarettes and tobacco. Vendors were contacted through social networks, family, and friends as well as common knowledge of people and places, particularly pubs where contraband was available. Most users of contraband considered that smugglers were providing a valuable service. Purchasing contraband tobacco was viewed as rational in the face of material hardship. Many smokers criticised the government for its high tobacco taxation and the lack of local services to help them to stop smoking. Conclusions Smokers in deprived areas perceive a lack of support to help them to stop smoking. Cigarette and tobacco smuggling is therefore viewed positively by low income smokers as a way of dealing with the increasing cost of cigarettes. Smokers in areas of deprivation may thus show little support for tackling smuggling until more action is taken to deal with the material and personal factors that make it difficult for them to quit. What is already known on this topicAreas of deprivation have the highest rates of smoking and lowest levels of cessationAround 25-30% of cigarettes consumed in the United Kingdom are contrabandWe know little about the attitudes of smokers in these areas to smuggled cigarettes or whether and

  4. Human-technology interaction for standoff IED detection

    Science.gov (United States)

    Zhang, Evan; Zou, Yiyang; Zachrich, Liping; Fulton, Jack

    2011-03-01

    IEDs kill our soldiers and innocent people every day. Lessons learned from Iraq and Afghanistan clearly indicated that IEDs cannot be detected/defeated by technology alone; human-technology interaction must be engaged. In most cases, eye is the best detector, brain is the best computer, and technologies are tools, they must be used by human being properly then can achieve full functionality. In this paper, a UV Raman/fluorescence, CCD and LWIR 3 sensor fusion system for standoff IED detection and a handheld fusion system for close range IED detection are developed and demonstrated. We must train solders using their eyes or CCD/LWIR cameras to do wide area search while on the move to find small suspected area first then use the spectrometer because the laser spot is too small, to scan a one-mile long and 2-meter wide road needs 185 days although our fusion system can detect the IED in 30m with 1s interrogating time. Even if the small suspected area (e.g., 0.5mx0.5m) is found, human eyes still cannot detect the IED, soldiers must use or interact with the technology - laser based spectrometer to scan the area then they are able to detect and identify the IED in 10 minutes not 185 days. Therefore, the human-technology interaction approach will be the best solution for IED detection.

  5. A high-order time-accurate interrogation method for time-resolved PIV

    International Nuclear Information System (INIS)

    Lynch, Kyle; Scarano, Fulvio

    2013-01-01

    A novel method is introduced for increasing the accuracy and extending the dynamic range of time-resolved particle image velocimetry (PIV). The approach extends the concept of particle tracking velocimetry by multiple frames to the pattern tracking by cross-correlation analysis as employed in PIV. The working principle is based on tracking the patterned fluid element, within a chosen interrogation window, along its individual trajectory throughout an image sequence. In contrast to image-pair interrogation methods, the fluid trajectory correlation concept deals with variable velocity along curved trajectories and non-zero tangential acceleration during the observed time interval. As a result, the velocity magnitude and its direction are allowed to evolve in a nonlinear fashion along the fluid element trajectory. The continuum deformation (namely spatial derivatives of the velocity vector) is accounted for by adopting local image deformation. The principle offers important reductions of the measurement error based on three main points: by enlarging the temporal measurement interval, the relative error becomes reduced; secondly, the random and peak-locking errors are reduced by the use of least-squares polynomial fits to individual trajectories; finally, the introduction of high-order (nonlinear) fitting functions provides the basis for reducing the truncation error. Lastly, the instantaneous velocity is evaluated as the temporal derivative of the polynomial representation of the fluid parcel position in time. The principal features of this algorithm are compared with a single-pair iterative image deformation method. Synthetic image sequences are considered with steady flow (translation, shear and rotation) illustrating the increase of measurement precision. An experimental data set obtained by time-resolved PIV measurements of a circular jet is used to verify the robustness of the method on image sequences affected by camera noise and three-dimensional motions. In

  6. PRODUCE BUYING AND MARKETING BOARDS IN NIGERIA: INTERROGATING THE FISCAL ROLE OF WESTERN NIGERIA MARKETING BOARD 1942-1962

    OpenAIRE

    Adeyinka Theresa Ajayi; Ajibade Idowu Samuel; Oladiti Abiodun Akeem

    2017-01-01

    Marketing Board system was one of the mechanisms of British colonial policy in Nigeria. Primary products were channeled through the Boards to Europe at the expense of both the Nigerian state and the farmers, the producers of these commodities. This study examines produce buying via Marketing Boards in Nigeria and specifically interrogates the fiscal role of Western Nigeria Marketing Board. It argues that the Marketing Boards, in spite of their exploitative nature was beneficial to the regiona...

  7. The plasticity of early memory reports: social pressure, hypnotizability, compliance, and interrogative suggestibility.

    Science.gov (United States)

    Malinoski, P T; Lynn, S J

    1999-10-01

    Early autobiographical memory reports by adults were very sensitive to social influence in a leading interview. The mean age of initial earliest memory report was 3.7 years. When participants were instructed to close their eyes, visualize, and focus on their 2nd birthday, 59% reported a birthday memory. After repeated probes for earlier memories, 78% of subjects reported memories at or prior to 24 months of age, and 33% reported memories within the first 12 months of age. The mean age of the final earliest memory reported was 1.6 years. Participants rated their memory reports as accurate and did not recant them when given an opportunity. The age of earliest memory reports in the suggestive interview correlated negatively with measures of compliance, hypnotizability, and interrogative suggestibility.

  8. Critically interrogating the fragmentation and weak institutionalization of ‘Communication Studies’ in Europe

    DEFF Research Database (Denmark)

    Phillips, Louise Jane

    robust and dynamic field”, Media Culture & Society, 35(8): 1019-1022. Jørgensen, M. and Phillips, L. (2002). Discourse Analysis as Theory and Method. London: Sage. Olssen, M. and Peters, M. 2005. ‘Neoliberalism, higher education and the knowledge economy: from the free market to knowledge capitalism......This paper will critically interrogate the marginalization of communication studies in the European research and education landscape. Drawing on a discourse theoretical approach (eg Jørgensen and Phillips 2002), it will analyse the marginalization of communication studies in the context of current...... conditions for knowledge production in the “neo-liberal university” and discuss the implications with respect to epistemological and political (im)possibilities and the play of power. The paper will first discuss the marginalization of ‘media and communication studies’ before concentrating...

  9. Mechanism of Genome Interrogation: How CRISPR RNA-Guided Cas9 Proteins Locate Specific Targets on DNA.

    Science.gov (United States)

    Shvets, Alexey A; Kolomeisky, Anatoly B

    2017-10-03

    The ability to precisely edit and modify a genome opens endless opportunities to investigate fundamental properties of living systems as well as to advance various medical techniques and bioengineering applications. This possibility is now close to reality due to a recent discovery of the adaptive bacterial immune system, which is based on clustered regularly interspaced short palindromic repeats (CRISPR)-associated proteins (Cas) that utilize RNA to find and cut the double-stranded DNA molecules at specific locations. Here we develop a quantitative theoretical approach to analyze the mechanism of target search on DNA by CRISPR RNA-guided Cas9 proteins, which is followed by a selective cleavage of nucleic acids. It is based on a discrete-state stochastic model that takes into account the most relevant physical-chemical processes in the system. Using a method of first-passage processes, a full dynamic description of the target search is presented. It is found that the location of specific sites on DNA by CRISPR Cas9 proteins is governed by binding first to protospacer adjacent motif sequences on DNA, which is followed by reversible transitions into DNA interrogation states. In addition, the search dynamics is strongly influenced by the off-target cutting. Our theoretical calculations allow us to explain the experimental observations and to give experimentally testable predictions. Thus, the presented theoretical model clarifies some molecular aspects of the genome interrogation by CRISPR RNA-guided Cas9 proteins. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  10. Design of a novel instrument for active neutron interrogation of artillery shells.

    Science.gov (United States)

    Bélanger-Champagne, Camille; Vainionpää, Hannes; Peura, Pauli; Toivonen, Harri; Eerola, Paula; Dendooven, Peter

    2017-01-01

    The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only) for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

  11. Microwave interrogated large core fused silica fiber Michelson interferometer for strain sensing.

    Science.gov (United States)

    Hua, Liwei; Song, Yang; Huang, Jie; Lan, Xinwei; Li, Yanjun; Xiao, Hai

    2015-08-20

    A Michelson-type large core optical fiber sensor has been developed, which is designed based on the optical carrier-based microwave interferometry technique, and fabricated by using two pieces of 200-μm diameter fused silica core fiber as two arms of the Michelson interferometer. The interference fringe pattern caused by the optical path difference of the two arms is interrogated in the microwave domain, where the fringe visibility of 40 dB has easily been obtained. The strain sensing at both room temperature and high temperatures has been demonstrated by using such a sensor. Experimental results show that this sensor has a linear response to the applied strain, and also has relatively low temperature-strain cross talk. The dopant-free quality of the fused silica fiber provides high possibility for the sensor to have promising strain sensing performance in a high temperature environment.

  12. Measurement of uranium and plutonium in solid waste by passive photon or neutron counting and isotopic neutron source interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Crane, T.W.

    1980-03-01

    A summary of the status and applicability of nondestructive assay (NDA) techniques for the measurement of uranium and plutonium in 55-gal barrels of solid waste is reported. The NDA techniques reviewed include passive gamma-ray and x-ray counting with scintillator, solid state, and proportional gas photon detectors, passive neutron counting, and active neutron interrogation with neutron and gamma-ray counting. The active neutron interrogation methods are limited to those employing isotopic neutron sources. Three generic neutron sources (alpha-n, photoneutron, and /sup 252/Cf) are considered. The neutron detectors reviewed for both prompt and delayed fission neutron detection with the above sources include thermal (/sup 3/He, /sup 10/BF/sub 3/) and recoil (/sup 4/He, CH/sub 4/) proportional gas detectors and liquid and plastic scintillator detectors. The instrument found to be best suited for low-level measurements (< 10 nCi/g) is the /sup 252/Cf Shuffler. The measurement technique consists of passive neutron counting followed by cyclic activation using a /sup 252/Cf source and delayed neutron counting with the source withdrawn. It is recommended that a waste assay station composed of a /sup 252/Cf Shuffler, a gamma-ray scanner, and a screening station be tested and evaluated at a nuclear waste site. 34 figures, 15 tables.

  13. FY09 Advanced Instrumentation and Active Interrogation Research for Safeguards

    International Nuclear Information System (INIS)

    Chichester, D.L.; Pozzi, S.A.; Seabury, E.H.; Dolan, J.L.; Flaska, M.; Johnson, J.T.; Watson, S.M.; Wharton, J.

    2009-01-01

    Multiple small-scale projects have been undertaken to investigate advanced instrumentation solutions for safeguard measurement challenges associated with advanced fuel cycle facilities and next-generation fuel reprocessing installations. These activities are in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and its Materials Protection, Accounting, and Control for Transmutation (MPACT) campaign. (1) Work was performed in a collaboration with the University of Michigan (Prof. Sara Pozzi, co-PI) to investigate the use of liquid-scintillator radiation detectors for assaying mixed-oxide (MOX) fuel, to characterize its composition and to develop advanced digital pulse-shape discrimination algorithms for performing time-correlation measurements in the MOX fuel environment. This work included both simulations and experiments and has shown that these techniques may provide a valuable approach for use within advanced safeguard measurement scenarios. (2) Work was conducted in a collaboration with Oak Ridge National Laboratory (Dr. Paul Hausladen, co-PI) to evaluate the strengths and weaknesses of the fast-neutron coded-aperture imaging technique for locating and characterizing fissile material, and as a tool for performing hold-up measurements in fissile material handling facilities. This work involved experiments at Idaho National Laboratory, using MOX fuel and uranium metal, in both passive and active interrogation configurations. A complete analysis has not yet been completed but preliminary results suggest several potential uses for the fast neutron imaging technique. (3) Work was carried out to identify measurement approaches for determining nitric acid concentration in the range of 1-4 M and beyond. This work included laboratory measurements to investigate the suitability of prompt-gamma neutron activation analysis for this measurement and product reviews of other commercial solutions. Ultrasonic density analysis appears to be

  14. Contraband of Falcons

    Directory of Open Access Journals (Sweden)

    Elvira G. Nikolenko

    2016-02-01

    Full Text Available According to the criminal proceeding in smuggling of falcons, former employees of the Line Internal Affairs Department in MIA transport, working in Domodedovo airport, were sentenced to large fines  - A. Kurokhtin, D. Gorodenko and A. Kustov, as was reported in Rossiyskaya Gazeta on 19.06.2013. Inspectors of the State Committee for the wild life protection together with employees of the MIA of Khakassia on 15.09.2013 detained two individuals engaged in illegal catching of falcons. On 04.11.2013 in Buryatia perpetrator, which transported 16 falcons, was arrested. On the road Khabarovsk-Chita in the vicinity of the village Nikolayevka in Jewish Autonomous Region (Russia police seized 21 Gyrfalcons (Falco rusticolus, which on 26.11.2013 was reported in STRBC “Dalnevostochnaya”. In the village Lesnoi of Yelizovo district in the Kamchatka Region on 29.11.2013, police arrested two men and seized eight Gyrfalcons (Falco rusticolus. One Saker Falcon (Falco cherrug seized on 12.12.2013 in the village Staroaleyskoe of Tretyakovo district of the Altai Kray (Russia. On 24.12.2013 in Petropavlovsk-Kamchatsky (Russia the police, together with colleagues from the regional FSSD seized 13 Gyrfalcons (Falco rusticolus from two residents of the Krasnoyarsk Territory. On 15.01.2014 in Kamchatka, the 51-year-old resident of the village of Nagorny in Yelizovski District, which kept 8 Gyrfalcons (Falco rusticolus in the garage at his house land plot, was arrested. Prosecution office of Tarbagatay district of East Kazakhstan region (Kazakhstan together with the police and the authorities for the wild life protection found 7 Saker Falcons (Falco cherrug on 06.08.2014. At security control point “Ak-tilek - roadway" (Kazakhstan on 29.08.2014 border guards together with employees of the State Customs Service apprehended a citizen of Kazakhstan, who tried to take from Kyrgyzstan to Kazakhstan 3 young Saker Falcons (Falco cherrug. Supervisors of safety department in Khakassky Reserve prevented the catching of Saker Falcons on the territory of SPNR in Ust-Abakan District on 30.08.2015. In forest-line near Chernogorsk, Republic of Khakassia (Russia employees of the State Committee for wildlife and environment protection found 9 Saker Falcons caught by poachers on 09.09.2014. On 18.09.2014 as a result of operational search activities, employees of Altai Customs and Border Service of FSS of RF in Altai Kray prevented an attempt of illegal export of 18 falcons from Russia via the Republic of Kazakhstan. On 26.09.2014 at “Vnukovo” airport employees of the FCS of Russia prevented smuggling of 4 Gyrfalcons (Falco rusticolus, but also identified two customs officials who assisted smugglers and moved alive goods without customs control. On October 23, 2014 in the Sanctuary of rare birds “Altai-Falcon” (Barnaul, the Altai Kray, Russia 10 falcons were released. On 27.10.2014 employees of Domodedovo Customs terminated an attempt of illegal export of 5 falcons from Russia to Armenia. On 10.30.2014 in Kamchatka officers of the Criminal Investigation Office of Milkovsky Department seized two Gyrfalcons (Falco rusticolus from poachers. On 02.11.2014 border guards of Kamchatka detained intercoastal ship, where was found hold to transport falcons. On 07.11.2014 batch of 6 falcons was detained by STSI inspectors in Slavgorod in the Altai Kray (Russia at Kazakhstan customs and gave a carrier to border guards. On 05.12.2014 in Chelyabinsk Airport a group of people trying to smuggle 3 Saker Falcons (Falco cherrug from Russia to Armenia, was detained. On 11.12.2014 in Tashkent (Uzbekistan 28 Saker Falcons (Falco cherrug were released, they were seized from poachers. On 12.16.2014 in Petropavlovsk-Kamchatsky (Russia 47-year-old citizen was seized two Gyrfalcons (Falco rusticolus. On 12.27.2014 in Moscow suburbs (Russia, a female Gyrfalcon (Falco rusticolus was found. In January 2015 two suitcases were found in the toilet in Moscow Sheremetyevo airport, where were 8 Gyrfalcons (Falco rusticolus. On 02.04.2015 the Sanctuary of rare birds “Altai-Falcon” (Barnaul, the Altai Territory, Russia released 14 falcons (7 Saker Falcons Falco cherrug and 7 Peregrine Falcons F. peregrinus, confiscated in autumn 2014. On July 8, 2015 at the “Domodedovo” airport a Bulgarian citizen, who found 25 eggs of the Peregrine Falcon (Falco peregrinus, was detained. On 08.09.2015 on the territory of the cluster in Khakassky State Nature Reserve “Kamyzyakskaya steppe with lake Ulug Kohl” (Khakassia, two citizens of Syria and one native of Azerbaijan were take while attempting to catch falcons. On 11.09.2015 at Domodedovo airport staff of Rosselkhoznadzor suspended clearance of 8 Gyrfalcons (Falco rusticolus, which was brought to Moscow from the United Arab Emirates. On 18.09.2015 as a result of joint operational-search activities, officers of Altai Customs and Border Service of Russian FSS prevented an attempt of illegal export of 14 falcons from Russia to Kazakhstan. On 14.09.2015 24 Falcons were found during the check of flight № FDV-738 “Shymkent – Dubai” (Karavan.kz. Four members of the organized criminal group, involved in smuggling of Gyrfalcons (Falco rusticolus, were detained at a Moscow airport “Sheremetyevo” on 17.10.2015. Belgorod custom officers were not allowed to take 8 Saker Falcons (Falco cherrug out of Russia  on 20.10.2015. On 10.11.2015 Gosohotsluzhba of The Zabaikalsky Kray (Russia in cooperation with the police in Chernyshevsky District of the Zabaikalsky Kray detained a group of six foreigners (Syrians, Kurds, Azerbaijanian for illegal catching of falcons. On 20.11.2015 in Kamchatka officers of the Criminal Investigation of Kamchatka Police together with colleagues from the FSS regional department detained a resident of Apuka village of Olyutorsky district, which was seized nine Gyrfalcons (Falco rusticolus. On November, 2015 in Kamchatka two criminal cases were initiated on the illegal transport and keeping of gyrfalcons (Falco rusticolus. On November, 2015 in Kamchatka two criminal cases were initiated on the illegal transport and keeping of gyrfalcons (Falco rusticolus. On 03.12.2015 in Kamchatka transport police prevented the export of 3 Gyrfalcons (Falco rusticolus by flight to Khabarovsk. On 21.12.2015 in Kamchatka a Gyrfalcon (Falco rusticolus was withdrawn from a resident of Oktybrski village of Ust-Bolsheretsky district.

  15. Ion Mobility Spectrometer / Mass Spectrometer (IMS-MS)

    Energy Technology Data Exchange (ETDEWEB)

    Hunka, Deborah E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Austin, Daniel [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2005-10-01

    The use of Ion Mobility Spectrometry (IMS)in the Detection of Contraband Sandia researchers use ion mobility spectrometers for trace chemical detection and analysis in a variety of projects and applications. Products developed in recent years based on IMS-technology include explosives detection personnel portals, the Material Area Access (MAA) checkpoint of the future, an explosives detection vehicle portal, hand-held detection systems such as the Hound and Hound II (all 6400), micro-IMS sensors (1700), ordnance detection (2500), and Fourier Transform IMS technology (8700). The emphasis to date has been on explosives detection, but the detection of chemical agents has also been pursued (8100 and 6400).

  16. Compact neutron generator

    Science.gov (United States)

    Leung, Ka-Ngo; Lou, Tak Pui

    2005-03-22

    A compact neutron generator has at its outer circumference a toroidal shaped plasma chamber in which a tritium (or other) plasma is generated. A RF antenna is wrapped around the plasma chamber. A plurality of tritium ion beamlets are extracted through spaced extraction apertures of a plasma electrode on the inner surface of the toroidal plasma chamber and directed inwardly toward the center of neutron generator. The beamlets pass through spaced acceleration and focusing electrodes to a neutron generating target at the center of neutron generator. The target is typically made of titanium tubing. Water is flowed through the tubing for cooling. The beam can be pulsed rapidly to achieve ultrashort neutron bursts. The target may be moved rapidly up and down so that the average power deposited on the surface of the target may be kept at a reasonable level. The neutron generator can produce fast neutrons from a T-T reaction which can be used for luggage and cargo interrogation applications. A luggage or cargo inspection system has a pulsed T-T neutron generator or source at the center, surrounded by associated gamma detectors and other components for identifying explosives or other contraband.

  17. Portable fluorescence lifetime spectroscopy system for in-situ interrogation of biological tissues

    Science.gov (United States)

    Saito Nogueira, Marcelo; Cosci, Alessandro; Teixeira Rosa, Ramon Gabriel; Salvio, Ana Gabriela; Pratavieira, Sebastião; Kurachi, Cristina

    2017-12-01

    Fluorescence spectroscopy and lifetime techniques are potential methods for optical diagnosis and characterization of biological tissues with an in-situ, fast, and noninvasive interrogation. Several diseases may be diagnosed due to differences in the fluorescence spectra of targeted fluorophores, when, these spectra are similar, considering steady-state fluorescence, others may be detected by monitoring their fluorescence lifetime. Despite this complementarity, most of the current fluorescence lifetime systems are not robust and portable, and not being feasible for clinical applications. We describe the assembly of a fluorescence lifetime spectroscopy system in a suitcase, its characterization, and validation with clinical measurements of skin lesions. The assembled system is all encased and robust, maintaining its mechanical, electrical, and optical stability during transportation, and is feasible for clinical measurements. The instrument response function measured was about 300 ps, and the system is properly calibrated. At the clinical study, the system showed to be reliable, and the achieved spectroscopy results support its potential use as an auxiliary tool for skin diagnostics.

  18. Design of a novel instrument for active neutron interrogation of artillery shells.

    Directory of Open Access Journals (Sweden)

    Camille Bélanger-Champagne

    Full Text Available The most common explosives can be uniquely identified by measuring the elemental H/N ratio with a precision better than 10%. Monte Carlo simulations were used to design two variants of a new prompt gamma neutron activation instrument that can achieve this precision. The instrument features an intense pulsed neutron generator with precise timing. Measuring the hydrogen peak from the target explosive is especially challenging because the instrument itself contains hydrogen, which is needed for neutron moderation and shielding. By iterative design optimization, the fraction of the hydrogen peak counts coming from the explosive under interrogation increased from [Formula: see text]% to [Formula: see text]% (statistical only for the benchmark design. In the optimized design variants, the hydrogen signal from a high-explosive shell can be measured to a statistics-only precision better than 1% in less than 30 minutes for an average neutron production yield of 109 n/s.

  19. Interrogating the Spatiotemporal Landscape of Neuromodulatory GPCR Signaling by Real-Time Imaging of cAMP in Intact Neurons and Circuits

    Directory of Open Access Journals (Sweden)

    Brian S. Muntean

    2018-01-01

    Full Text Available Summary: Modulation of neuronal circuits is key to information processing in the brain. The majority of neuromodulators exert their effects by activating G-protein-coupled receptors (GPCRs that control the production of second messengers directly impacting cellular physiology. How numerous GPCRs integrate neuromodulatory inputs while accommodating diversity of incoming signals is poorly understood. In this study, we develop an in vivo tool and analytical suite for analyzing GPCR responses by monitoring the dynamics of a key second messenger, cyclic AMP (cAMP, with excellent quantitative and spatiotemporal resolution in various neurons. Using this imaging approach in combination with CRISPR/Cas9 editing and optogenetics, we interrogate neuromodulatory mechanisms of defined populations of neurons in an intact mesolimbic reward circuit and describe how individual inputs generate discrete second-messenger signatures in a cell- and receptor-specific fashion. This offers a resource for studying native neuronal GPCR signaling in real time. : Muntean et al. develop an in vivo reagent to study processing of neurotransmitter GPCR signals by monitoring real-time dynamics of cAMP responses. They demonstrate application of this approach, in combination with CRISPR/Cas9 gene editing and optogenetics, to interrogate the functional organization of a striatal circuit. Keywords: cAMP, GPCR, neuromodulation, dopamine, striatum, imaging, optogenetics

  20. Development of high sensitivity eight-element multiplexed fiber laser acoustic pressure hydrophone array and interrogation system

    Science.gov (United States)

    Li, Ming; Sun, Zhihui; Zhang, Xiaolei; Li, Shujuan; Song, Zhiqiang; Wang, Meng; Guo, Jian; Ni, Jiasheng; Wang, Chang; Peng, Gangding; Xu, Xiangang

    2017-09-01

    Fiber laser hydrophones have got widespread concerns due to the unique advantages and broad application prospects. In this paper, the research results of the eight-element multiplexed fiber laser acoustic pressure array and the interrogation system are introduced, containing low-noise distributed feedback fiber laser (DFB-FL) fabrication, sensitivity enhancement packaging, and interferometric signal demodulation. The frequency response range of the system is 10Hz-10kHz, the laser frequency acoustic pressure sensitivity reaches 115 dB re Hz/Pa, and the equivalent noise acoustic pressure is less than 60μPa/Hz1/2. The dynamic range of the system is greater than 120 dB.

  1. Reaction of Br2 with adsorbed CO on Pt, studied by the surface interrogation mode of scanning electrochemical microscopy.

    Science.gov (United States)

    Wang, Qian; Rodríguez-López, Joaquín; Bard, Allen J

    2009-12-02

    Scanning electrochemical microscopy surface interrogation (SI-SECM) in the cyclic voltammetry mode was successfully used to detect and quantify adsorbed CO on a Pt electrode by reaction with electrogenerated Br(2). The two-electrode setup used in this new technique allowed the production of Br(2) on an interrogator tip, which reported a transient positive feedback above a Pt substrate at open circuit as an indication of the reactivity of this halogen with CO((ads)). Br(-) and CO(2) are shown to be the main products of the reaction (in the absence of O(2)), which may involve the formation of bromophosgene as a hydrolyzable intermediate. Under saturation conditions, CO((ads)) was reproducibly quantified at the polycrystalline Pt surface with theta(CO) approximately = 0.5. The reaction is shown to be blocked by the action of pre-adsorbed cyanide, which demonstrates the surface character of the process. The formation of CO(2) as an end product was further tested in a bulk experiment: addition of Pt black to a mixture of Br(2) in 0.5 M H(2)SO(4) through which CO was bubbled gave a precipitate of BaCO(3) in a saturated solution of Ba(OH)(2). The use of SI-SECM allowed access to a reaction that would otherwise be difficult to prove through conventional electrochemistry on a single electrode.

  2. Unexploded Ordnance identification—A gamma-ray spectral analysis method for Carbon, Nitrogen and Oxygen signals following tagged neutron interrogation

    International Nuclear Information System (INIS)

    Mitra, S.; Dioszegi, I.

    2012-01-01

    A novel gamma-ray spectral analysis method has been demonstrated to optimally extract the signals of the signature elements of explosives, carbon (C), nitrogen (N) and oxygen (O) from 57–155 mm projectiles following tagged neutron interrogation with 14 MeV neutrons. The method was implemented on Monte Carlo simulated, synthetic spectra of Unexploded Ordnance (UXO) that contained high explosive fillers (Composition B, TNT or Explosive D) within steel casings of appropriate thicknesses. The analysis technique defined three broad regions-of-interest (ROI) between 4–7.5 MeV of a spectrum and from a system of three equations for the three unknowns namely C, N and O, the maximum counts from each of these elements were extracted. Unlike conventional spectral analysis techniques, the present method included the Compton continuum under a spectrum. For a neutron output of ∼2×10 7 ns −1 and using four 12.7 cm diameter×12.7 cm NaI(Tl) detectors, the C/N and C/O gamma-ray counts ratios of the explosive fillers were vastly different from that of an inert substance like sand. Conversion of the counts ratios to elemental ratios could further discriminate the different types of explosive fillers. The interrogation time was kept at ten minutes for each projectile.

  3. High-throughput metagenomic technologies for complex microbial community analysis: open and closed formats.

    Science.gov (United States)

    Zhou, Jizhong; He, Zhili; Yang, Yunfeng; Deng, Ye; Tringe, Susannah G; Alvarez-Cohen, Lisa

    2015-01-27

    Understanding the structure, functions, activities and dynamics of microbial communities in natural environments is one of the grand challenges of 21st century science. To address this challenge, over the past decade, numerous technologies have been developed for interrogating microbial communities, of which some are amenable to exploratory work (e.g., high-throughput sequencing and phenotypic screening) and others depend on reference genes or genomes (e.g., phylogenetic and functional gene arrays). Here, we provide a critical review and synthesis of the most commonly applied "open-format" and "closed-format" detection technologies. We discuss their characteristics, advantages, and disadvantages within the context of environmental applications and focus on analysis of complex microbial systems, such as those in soils, in which diversity is high and reference genomes are few. In addition, we discuss crucial issues and considerations associated with applying complementary high-throughput molecular technologies to address important ecological questions. Copyright © 2015 Zhou et al.

  4. INTERROGATION DU MYTHE DE L'ENTREPRENEUR A TRAVERS LA TRAJECTOIRE INÉGALE D'UN CRÉATEUR PERSISTANT

    OpenAIRE

    Vincent Lagarde

    2006-01-01

    International audience; Le créateur persistant, archétype de l'entrepreneur, a fait l'objet de plusieurs descriptions théoriques, mais a été peu observé durablement. L'étude des trajectoires double-décennales d'un échantillon d'entrepreneurs agricoles atypiques, a été l'occasion de rechercher et d'analyser des comportements de créateurs persistants. La situation du seul cas résistant à l'analyse sur les 20 années, révèle quelques paradoxes qui interrogent la théorie. Les changements fréquents...

  5. Questions about the future of the nuclear energy; Les interrogations sur l'avenir de l'energie nucleaire

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-12-15

    The nuclear energy became a society subject much debated. This analysis discusses in three chapters the different interrogations concerning the nuclear energy: the comparison between the different energy sources to justify the preservation of the nuclear energy in France and in the world, the compatibility of the nuclear energy with the different socio-economic choices as the main condition of its development, and the role of the Government to transform the energy policy on the society choice. (A.L.B.)

  6. Dielectric RheoSANS - Simultaneous Interrogation of Impedance, Rheology and Small Angle Neutron Scattering of Complex Fluids.

    Science.gov (United States)

    Richards, Jeffrey J; Gagnon, Cedric V L; Krzywon, Jeffery R; Wagner, Norman J; Butler, Paul D

    2017-04-10

    A procedure for the operation of a new dielectric RheoSANS instrument capable of simultaneous interrogation of the electrical, mechanical and microstructural properties of complex fluids is presented. The instrument consists of a Couette geometry contained within a modified forced convection oven mounted on a commercial rheometer. This instrument is available for use on the small angle neutron scattering (SANS) beamlines at the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR). The Couette geometry is machined to be transparent to neutrons and provides for measurement of the electrical properties and microstructural properties of a sample confined between titanium cylinders while the sample undergoes arbitrary deformation. Synchronization of these measurements is enabled through the use of a customizable program that monitors and controls the execution of predetermined experimental protocols. Described here is a protocol to perform a flow sweep experiment where the shear rate is logarithmically stepped from a maximum value to a minimum value holding at each step for a specified period of time while frequency dependent dielectric measurements are made. Representative results are shown from a sample consisting of a gel composed of carbon black aggregates dispersed in propylene carbonate. As the gel undergoes steady shear, the carbon black network is mechanically deformed, which causes an initial decrease in conductivity associated with the breaking of bonds comprising the carbon black network. However, at higher shear rates, the conductivity recovers associated with the onset of shear thickening. Overall, these results demonstrate the utility of the simultaneous measurement of the rheo-electro-microstructural properties of these suspensions using the dielectric RheoSANS geometry.

  7. Active interrogation of highly enriched uranium

    Science.gov (United States)

    Fairrow, Nannette Lea

    Safeguarding special nuclear material (SNM) in the Department of Energy Complex is vital to the national security of the United States. Active and passive nondestructive assays are used to confirm the presence of SNM in various configurations ranging from waste to nuclear weapons. Confirmation measurements for nuclear weapons are more challenging because the design complicates the detection of a distinct signal for highly enriched uranium. The emphasis of this dissertation was to investigate a new nondestructive assay technique that provides an independent and distinct signal to confirm the presence of highly enriched uranium (HEU). Once completed and tested this assay method could be applied to confirmation measurements of nuclear weapons. The new system uses a 14-MeV neutron source for interrogation and records the arrival time of neutrons between the pulses with a high efficiency detection system. The data is then analyzed by the Feynman reduced variance method. The analysis determined the amount of correlation in the data and provided a unique signature of correlated fission neutrons. Measurements of HEU spheres were conducted at Los Alamos with the new system. Then, Monte Carlo calculations were performed to verify hypothesis made about the behavior of the neutrons in the experiment. Comparisons of calculated counting rates by the Monte Carlo N-Particle Transport Code (MCNP) were made with the experimental data to confirm that the measured response reflected the desired behavior of neutron interactions in the highly enriched uranium. In addition, MCNP calculations of the delayed neutron build-up were compared with the measured data. Based on the results obtained from this dissertation, this measurement method has the potential to be expanded to include mass determinations of highly enriched uranium. Although many safeguards techniques exist for measuring special nuclear material, the number of assays that can be used to confirm HEU in shielded systems is

  8. Wavelength-Agile Optical Sensor for Exhaust Plume and Cryogenic Fluid Interrogation

    Science.gov (United States)

    Sanders, Scott T.; Chiaverini, Martin J.; Gramer, Daniel J.

    2004-01-01

    Two optical sensors developed in UW-Madison labs were evaluated for their potential to characterize rocket engine exhaust plumes and liquid oxygen (LOX) fluid properties. The plume sensor is based on wavelength-agile absorption spectroscopy A device called a chirped white pulse emitter (CWPE) is used to generate the wavelength agile light, scanning, for example, 1340 - 1560 nm every microsecond. Properties of the gases in the rocket plume (for example temperature and water mole fraction) can be monitored using these wavelength scans. We have performed preliminary tests in static gas cells, a laboratory GOX/GH2 thrust chamber, and a solid-fuel hybrid thrust chamber, and these initial tests demonstrate the potential of the CWPE for monitoring rocket plumes. The LOX sensor uses an alternative to wavelength agile sensing: two independent, fixed-wavelength lasers are combined into a single fiber. One laser is absorbed by LOX and the other not: by monitoring the differential transmission the LOX concentration in cryogenic feed lines can be inferred. The sensor was successful in interrogating static LOX pools in laboratory tests. Even in ice- and bubble-laden cryogenic fluids, LOX concentrations were measured to better than 1% with a 3 microsec time constant.

  9. Signal predictions for a proposed fast neutron interrogation method

    International Nuclear Information System (INIS)

    Sale, K.E.

    1992-12-01

    We have applied the Monte Carlo radiation transport code COG) to assess the utility of a proposed explosives detection scheme based on neutron emission. In this scheme a pulsed neutron beam is generated by an approximately seven MeV deuteron beam incident on a thick Be target. A scintillation detector operating in the current mode measures the neutrons transmitted through the object as a function of time. The flight time of unscattered neutrons from the source to the detector is simply related to the neutron energy. This information along with neutron cross section excitation functions is used to infer the densities of H, C, N and O in the volume sampled. The code we have chosen to use enables us to create very detailed and realistic models of the geometrical configuration of the system, the neutron source and of the detector response. By calculating the signals that will be observed for several configurations and compositions of interrogated object we can investigate and begin to understand how a system that could actually be fielded will perform. Using this modeling capability many early on with substantial savings in time and cost and with improvements in performance. We will present our signal predictions for simple single element test cases and for explosive compositions. From these studies it is dear that the interpretation of the signals from such an explosives identification system will pose a substantial challenge

  10. Evaluation of Electromagnetic Induction (EMI) Resistivity Technologies for Assessing Permafrost Geomorphologies

    Science.gov (United States)

    2016-08-01

    resistivity, have been used to interrogate the subsur- face in permafrost terrains at the meters to kilometers scales. Airborne measurement techniques have...burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden to Department of Defense... interrogate the subsurface in permafrost terrains at the meters to kilometers scales. Airborne measurement techniques have broad applicability at the

  11. Interrogation of metabolic and oxygen states of tumors with fiber-based luminescence lifetime spectroscopy.

    Science.gov (United States)

    Lukina, Maria; Orlova, Anna; Shirmanova, Marina; Shirokov, Daniil; Pavlikov, Anton; Neubauer, Antje; Studier, Hauke; Becker, Wolfgang; Zagaynova, Elena; Yoshihara, Toshitada; Tobita, Seiji; Shcheslavskiy, Vladislav

    2017-02-15

    The study of metabolic and oxygen states of cells in a tumor in vivo is crucial for understanding of the mechanisms responsible for tumor development and provides background for the relevant tumor's treatment. Here, we show that a specially designed implantable fiber-optic probe provides a promising tool for optical interrogation of metabolic and oxygen states of a tumor in vivo. In our experiments, the excitation light from a ps diode laser source is delivered to the sample through an exchangeable tip via a multimode fiber, and the emission light is transferred to the detector by another multimode fiber. Fluorescence lifetime of a nicotinamid adenine dinucleotide (NAD(P)H) and phosphorescence lifetime of an oxygen sensor based on an iridium (III) complex of enzothienylpyridine (BTPDM1) are explored both in model experiment in solutions and in living mice.

  12. Opium: The Evolution of Policies, the Tolerance of the Vice, and the Proliferation of Contraband Trade in the Philippines, 1843-1908

    Directory of Open Access Journals (Sweden)

    Alma N. Bamero

    2006-12-01

    Full Text Available This research entitled “Opium: The Evolution of Policies, the Tolerance of the Vice, and the Proliferation of Contraband Trade in the Philippines, 1843-1908” presents a discussion of the opium trade in Asia, the commercial networks it created, the political ties it strengthened, and the social relations itfostered. It also aims to reconstruct an aspect of Philippine social history in the nineteenth century through the use of archival materials that bear witness to the distribution and exploitation of a substance which some people stillclassify as taboo. The poppy was not endemic to the Philippines but opium, its derivative substance, was known to numb pain and could induce a “natural high” that left one with feelings of ease and contentment. A more complete introduction to the drug necessitates a discussion of the way it was extractedand processed. It is a cash crop that does not require complex devices and is, therefore, within the reach of farmers and common folk. From the eighteenth to the nineteenth centuries opium became very popular among the Chinese who discovered that their markets were being flooded with it by the British sothat the latter could pay for the tea that they craved.The Spanish Bourbons, in an effort to boost Philippine economy, allowed the trading of this substance. Initially this was supervised by the officials of the Alcaiceria de San Fernando but in 1843 the meticulous examination of the country’s finances merited the creation of an opium revenuefarm through municipal franchising. Opium could only be used by the Chinese who were migrating in big groups. This paper presents the details of the monopoly contract, identifies some of the wealthier contratistas of the period, and discusses the consequences of such a commercial venture. Smuggling orcontraband trade proliferated and by way of illustration the events namely, the Scandal of 1843 and the Gunga Incident, have been narrated. The creation of an over

  13. Portable fluorescence lifetime spectroscopy system for in-situ interrogation of biological tissues.

    Science.gov (United States)

    Saito Nogueira, Marcelo; Cosci, Alessandro; Teixeira Rosa, Ramon Gabriel; Salvio, Ana Gabriela; Pratavieira, Sebastião; Kurachi, Cristina

    2017-10-01

    Fluorescence spectroscopy and lifetime techniques are potential methods for optical diagnosis and characterization of biological tissues with an in-situ, fast, and noninvasive interrogation. Several diseases may be diagnosed due to differences in the fluorescence spectra of targeted fluorophores, when, these spectra are similar, considering steady-state fluorescence, others may be detected by monitoring their fluorescence lifetime. Despite this complementarity, most of the current fluorescence lifetime systems are not robust and portable, and not being feasible for clinical applications. We describe the assembly of a fluorescence lifetime spectroscopy system in a suitcase, its characterization, and validation with clinical measurements of skin lesions. The assembled system is all encased and robust, maintaining its mechanical, electrical, and optical stability during transportation, and is feasible for clinical measurements. The instrument response function measured was about 300 ps, and the system is properly calibrated. At the clinical study, the system showed to be reliable, and the achieved spectroscopy results support its potential use as an auxiliary tool for skin diagnostics. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  14. An automated entry control system for nuclear facilities

    International Nuclear Information System (INIS)

    Ream, W.K.; Espinoza, J.

    1985-01-01

    An entry control system to automatically control access to nuclear facilities is described. The design uses a centrally located console, integrated into the regular security system, to monitor the computer-controlled passage into and out of sensitive areas. Four types of entry control points are used: an unmanned enclosed portal with metal and SNM detectors for contraband detection with positive personnel identification, a bypass portal for contraband search after a contraband alarm in a regular portal also with positive personnel identification, a single door entry point with positive personnel identification, and a single door entry point with only a magnetic card-type identification. Security force action is required only as a response to an alarm. The integration of the entry control function into the security system computer is also described. The interface between the entry control system and the monitoring security personnel utilizing a color graphics display with touch screen input is emphasized

  15. Automated entry control system for nuclear facilities

    International Nuclear Information System (INIS)

    Ream, W.K.; Espinoza, J.

    1985-01-01

    An entry control system to automatically control access to nuclear facilities is described. The design uses a centrally located console, integrated into the regular security system, to monitor the computer-controlled passage into and out of sensitive areas. Four types of entry control points are used: an unmanned enclosed portal with metal and SNM detectors for contraband detection with positive personnel identification, a bypass portal for contraband search after a contraband alarm in a regular portal also with positive personnel identification, a single door entry point with positive personnel identification, and a single door entry point with only a magnetic card-type identification. Security force action is required only as a response to an alarm. The integration of the entry control function into the security system computer is also described. The interface between the entry control system and the monitoring security personnel utilizing a color graphics display with touch screen input is emphasized. 2 refs., 7 figs

  16. Nanoscale Plasmonic V-Groove Waveguides for the Interrogation of Single Fluorescent Bacterial Cells.

    Science.gov (United States)

    Lotan, Oren; Bar-David, Jonathan; Smith, Cameron L C; Yagur-Kroll, Sharon; Belkin, Shimshon; Kristensen, Anders; Levy, Uriel

    2017-09-13

    We experimentally demonstrate the interrogation of an individual Escherichia coli cell using a nanoscale plasmonic V-groove waveguide. Several different configurations were studied. The first involved the excitation of the cell in a liquid environment because it flows on top of the waveguide nanocoupler, while the obtained fluorescence is coupled into the waveguide and collected at the other nanocoupler. The other two configurations involved the positioning of the bacterium within the nanoscale waveguide and its excitation in a dry environment either directly from the top or through waveguide modes. This is achieved by taking advantage of the waveguide properties not only for light guiding but also as a mechanical tool for trapping the bacteria within the V-grooves. The obtained results are supported by a set of numerical simulations, shedding more light on the mechanism of excitation. This demonstration paves the way for the construction of an efficient bioplasmonic chip for diverse cell-based sensing applications.

  17. Parallelised photoacoustic signal acquisition using a Fabry-Perot sensor and a camera-based interrogation scheme

    Science.gov (United States)

    Saeb Gilani, T.; Villringer, C.; Zhang, E.; Gundlach, H.; Buchmann, J.; Schrader, S.; Laufer, J.

    2018-02-01

    Tomographic photoacoustic (PA) images acquired using a Fabry-Perot (FP) based scanner offer high resolution and image fidelity but can result in long acquisition times due to the need for raster scanning. To reduce the acquisition times, a parallelised camera-based PA signal detection scheme is developed. The scheme is based on using a sCMOScamera and FPI sensors with high homogeneity of optical thickness. PA signals were acquired using the camera-based setup and the signal to noise ratio (SNR) was measured. A comparison of the SNR of PA signal detected using 1) a photodiode in a conventional raster scanning detection scheme and 2) a sCMOS camera in parallelised detection scheme is made. The results show that the parallelised interrogation scheme has the potential to provide high speed PA imaging.

  18. Surface Interrogation Scanning Electrochemical Microscopy for a Photoelectrochemical Reaction: Water Oxidation on a Hematite Surface.

    Science.gov (United States)

    Kim, Jae Young; Ahn, Hyun S; Bard, Allen J

    2018-03-06

    To understand the pathway of a photoelectrochemical (PEC) reaction, quantitative knowledge of reaction intermediates is important. We describe here surface interrogation scanning electrochemical microscopy for this purpose (PEC SI-SECM), where a light pulse to a photoactive semiconductor film at a given potential generates intermediates that are then analyzed by a tip generated titrant at known times after the light pulse. The improvements were demonstrated for photoelectrochemical water oxidation (oxygen evolution) reaction on a hematite surface. The density of photoactive sites, proposed to be Fe 4+ species, on a hematite surface was successfully quantified, and the photoelectrochemical water oxidation reaction dynamics were elucidated by time-dependent redox titration experiments. The new configuration of PEC SI-SECM should find expanded usage to understand and investigate more complicated PEC reactions with other materials.

  19. Laboratory evaluation of two x-ray baggage inspection systems

    International Nuclear Information System (INIS)

    Schellenbaum, R.L.

    1979-06-01

    The AS and E Micro-Dose X-ray Baggage Inspection System was designed for high-volume, detailed examination of packages at ultralow x-ray exposure levels. This system is used in airline terminals for the detection of weapons, bombs, and other contraband. It is also employed by security personnel in other facilities to search packages for contraband carried in and out of secured areas. The Micro-Dose system has a unique design concept which includes an Automatic Threat Alert System (ATA) and a zoom display presentation feature

  20. Uniform spacing interrogation of a Fourier domain mode-locked fiber Bragg grating sensor system using a polarization-maintaining fiber Sagnac interferometer

    OpenAIRE

    Lee, Hwi Don; Jung, Eun Joo; Jeong, Myung Yung; Chen, Zhongping; Kim, Chang-Seok

    2013-01-01

    A novel linearized interrogation method is presented for a Fourier domain mode-locked (FDML) fiber Bragg grating (FBG) sensor system. In a high speed regime over several tens of kHz modulations, a sinusoidal wave is available to scan the center wavelength of an FDML wavelength-swept laser, instead of a conventional triangular wave. However, sinusoidal wave modulation suffers from an exaggerated non-uniform wavelength-spacing response in demodulating the time-encoded parameter to the absolute ...

  1. Interrogating resilience: toward a typology to improve its operationalization

    Directory of Open Access Journals (Sweden)

    Julie L. Davidson

    2016-06-01

    Full Text Available In the context of accelerated global change, the concept of resilience, with its roots in ecological theory and complex adaptive systems, has emerged as the favored framework for understanding and responding to the dynamics of change. Its transfer from ecological to social contexts, however, has led to the concept being interpreted in multiple ways across numerous disciplines causing significant challenges for its practical application. The aim of this paper is to improve conceptual clarity within resilience thinking so that resilience can be interpreted and articulated in ways that enhance its utility and explanatory power, not only theoretically but also operationally. We argue that the current confusion and ambiguity within resilience thinking is problematic for operationalizing the concept within policy making. To achieve our aim, we interrogate resilience interpretations used within a number of academic and practice domains in the forefront of contending with the disruptive and sometimes catastrophic effects of global change (primarily due to climate change on ecological and human-nature systems. We demonstrate evolution and convergence among disciplines in the interpretations and theoretical underpinnings of resilience and in engagement with cross-scale considerations. From our analysis, we identify core conceptual elements to be considered in policy responses if resilience is to fulfill its potential in improving decision making for change. We offer an original classification of resilience definitions in current use and a typology of resilience interpretations. We conclude that resilience thinking must be open to alternative traditions and interpretations if it is to become a theoretically and operationally powerful paradigm.

  2. Monopolios, aranceles y contrabando en Nueva Granada, 1821-1830

    Directory of Open Access Journals (Sweden)

    Muriel Laurent

    2011-06-01

    Full Text Available Este artículo estudia el contrabando en Nueva Granada durante la primera década postindependentista. En un contexto en el que la reglamentación aduanera y comercial continuaba siendo proteccionista y fiscalista, a pesar de la pertinencia cada vez más aceptada de los argumentos a favor del libre cambio, se examina el comportamiento del comercio ilícito. El objetivo consiste en determinar cuál fue la relación entre esta reglamentación y el contrabando y en evaluar si la tendencia que considera que a mayor prohibición o mayor gravamen mayor contrabando se verifica en Nueva Granada entre 1821 y 1830; asimismo, en caso de verificarse, establecer si el contrabando recayó más en los productos prohibidos o en los más gravados.This article studies contraband in New Granada during the first decade after Independence. Given that the regulation of customs and trade remained protectionist and fiscally oriented, despite the growing acceptance of arguments in favor of free trade, it examines what happened to this illicit trade. The article tries to determine the relationship between these regulations and contraband. It also evaluates whether the frequently-held assumption that increasing prohibition or taxes on trade leads to a rise in contraband holds true for Colombia. If it does hold true, the article also attempts to establish whether or not there was greater contraband in prohibited or highly-taxes products.

  3. High-sensitive detection by direct interrogation of 14 MeV Acc neutrons, (1). Uranium-contained metal matrix in a waste dram

    International Nuclear Information System (INIS)

    Haruyama, Mitsuo; Takase, Misao; Tobita, Hiroshi; Mori, Takamasa

    2004-01-01

    Previously, authors reported that the 14 MeV-neutron direct interrogation method has made possible measure for the discrimination of clearance levels of concrete solidification uranium waste. In this paper, applicability of the method to metal waste matrix is discussed based on the results of simulation experiments by the continuation energy Monte Carlo calculation code (MVP). The problem is that self-neutron moderation effect in a waste cannot be expected when a waste matrix is metal. To solve this, a moderator is adopted so as to surround a metal waste drum and to slow down suitably a 14 MeV neutrons. The simulation calculation showed that this effect is satisfactorily large. The detection limit of radioactivity concentration to 4.5% enriched uranium has been found to be 0.0973 Bq/g in the metal waste model of 215.59 kg gross weight, in which 61 pipes are stuffed into its drum. Moreover, the position-dependent sensitivity difference in a metal waste drum can be settled as small as to ±13.5%. In conclusion, it can be said that 14 MeV-neutron direct interrogation method can be applied to the waste of a metal system: the detection sensitivity is high enough and the position-dependent sensitivity difference is small admittedly. Hence the method can be applied also to discrimination measurement of the clearance level of metal uranium waste. (author)

  4. Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel—Design concept and experimental demonstration

    International Nuclear Information System (INIS)

    Henzlova, D.; Menlove, H.O.; Rael, C.D.; Trellue, H.R.; Tobin, S.J.; Park, Se-Hwan; Oh, Jong-Myeong; Lee, Seung-Kyu; Ahn, Seong-Kyu; Kwon, In-Chan; Kim, Ho-Dong

    2016-01-01

    This paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. This paper describes the initial feasibility demonstration of the CIPN instrument, which involved measurements of four pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. These features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.

  5. Californium interrogation prompt neutron (CIPN) instrument for non-destructive assay of spent nuclear fuel—Design concept and experimental demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Henzlova, D., E-mail: henzlova@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Menlove, H.O.; Rael, C.D.; Trellue, H.R.; Tobin, S.J. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Park, Se-Hwan; Oh, Jong-Myeong; Lee, Seung-Kyu; Ahn, Seong-Kyu; Kwon, In-Chan; Kim, Ho-Dong [Korea Atomic Energy Research Institute, Daejeong (Korea, Republic of)

    2016-01-11

    This paper presents results of the first experimental demonstration of the Californium Interrogation Prompt Neutron (CIPN) instrument developed within a multi-year effort launched by the Next Generation Safeguards Initiative Spent Fuel Project of the United States Department of Energy. The goals of this project focused on developing viable non-destructive assay techniques with capabilities to improve an independent verification of spent fuel assembly characteristics. For this purpose, the CIPN instrument combines active and passive neutron interrogation, along with passive gamma-ray measurements, to provide three independent observables. This paper describes the initial feasibility demonstration of the CIPN instrument, which involved measurements of four pressurized-water-reactor spent fuel assemblies with different levels of burnup and two initial enrichments. The measurements were performed at the Post-Irradiation Examination Facility at the Korea Atomic Energy Institute in the Republic of Korea. The key aim of the demonstration was to evaluate CIPN instrument performance under realistic deployment conditions, with the focus on a detailed assessment of systematic uncertainties that are best evaluated experimentally. The measurements revealed good positioning reproducibility, as well as a high degree of insensitivity of the CIPN instrument's response to irregularities in a radial burnup profile. Systematic uncertainty of individual CIPN instrument signals due to assembly rotation was found to be <4.5%, even for assemblies with fairly extreme gradients in the radial burnup profile. These features suggest that the CIPN instrument is capable of providing a good representation of assembly average characteristics, independent of assembly orientation in the instrument.

  6. Performance Optimization Design for a High-Speed Weak FBG Interrogation System Based on DFB Laser

    Directory of Open Access Journals (Sweden)

    Yiqiang Yao

    2017-06-01

    Full Text Available A performance optimization design for a high-speed fiber Bragg grating (FBG interrogation system based on a high-speed distributed feedback (DFB swept laser is proposed. A time-division-multiplexing sensor network with identical weak FBGs is constituted to realize high-capacity sensing. In order to further improve the multiplexing capacity, a waveform repairing algorithm is designed to extend the dynamic demodulation range of FBG sensors. It is based on the fact that the spectrum of an FBG keeps stable over a long period of time. Compared with the pre-collected spectra, the distorted spectra waveform are identified and repaired. Experimental results show that all the identical weak FBGs are distinguished and demodulated at the speed of 100 kHz with a linearity of above 0.99, and the range of dynamic demodulation is extended by 40%.

  7. A Method for Vibration-Based Structural Interrogation and Health Monitoring Based on Signal Cross-Correlation

    International Nuclear Information System (INIS)

    Trendafilova, I

    2011-01-01

    Vibration-based structural interrogation and health monitoring is a field which is concerned with the estimation of the current state of a structure or a component from its vibration response with regards to its ability to perform its intended function appropriately. One way to approach this problem is through damage features extracted from the measured structural vibration response. This paper suggests to use a new concept for the purposes of vibration-based health monitoring. The correlation between two signals, an input and an output, measured on the structure is used to develop a damage indicator. The paper investigates the applicability of the signal cross-correlation and a nonlinear alternative, the average mutual information between the two signals, for the purposes of structural health monitoring and damage assessment. The suggested methodology is applied and demonstrated for delamination detection in a composite beam.

  8. Performance Optimization Design for a High-Speed Weak FBG Interrogation System Based on DFB Laser.

    Science.gov (United States)

    Yao, Yiqiang; Li, Zhengying; Wang, Yiming; Liu, Siqi; Dai, Yutang; Gong, Jianmin; Wang, Lixin

    2017-06-22

    A performance optimization design for a high-speed fiber Bragg grating (FBG) interrogation system based on a high-speed distributed feedback (DFB) swept laser is proposed. A time-division-multiplexing sensor network with identical weak FBGs is constituted to realize high-capacity sensing. In order to further improve the multiplexing capacity, a waveform repairing algorithm is designed to extend the dynamic demodulation range of FBG sensors. It is based on the fact that the spectrum of an FBG keeps stable over a long period of time. Compared with the pre-collected spectra, the distorted spectra waveform are identified and repaired. Experimental results show that all the identical weak FBGs are distinguished and demodulated at the speed of 100 kHz with a linearity of above 0.99, and the range of dynamic demodulation is extended by 40%.

  9. Determination of spent nuclear fuel assembly multiplication with the differential die-away self-interrogation instrument

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, Alexis C. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States); Henzl, Vladimir; Menlove, Howard O.; Swinhoe, Martyn T.; Belian, Anthony P. [Los Alamos National Laboratory, Los Alamos, NM 87544 (United States); Flaska, Marek; Pozzi, Sara A. [Department of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, MI 48109 (United States)

    2014-09-01

    We present a novel method for determining the multiplication of a spent nuclear fuel assembly with a Differential Die-Away Self-Interrogation (DDSI) instrument. The signal, which is primarily created by thermal neutrons, is measured with four {sup 3}He detector banks surrounding a spent fuel assembly. The Rossi-alpha distribution (RAD) at early times reflects coincident events from single fissions as well as fission chains. Because of this fact, the early time domain contains information about both the fissile material and spontaneous fission material in the assembly being measured. A single exponential function fit to the early time domain of the RAD has a die-away time proportional to the spent fuel assembly (SFA) multiplication. This correlation was tested by simulating assay of 44 different SFAs with the DDSI instrument. The SFA multiplication was determined with a variance of 0.7%.

  10. Benchmark for Peak Detection Algorithms in Fiber Bragg Grating Interrogation and a New Neural Network for its Performance Improvement

    Science.gov (United States)

    Negri, Lucas; Nied, Ademir; Kalinowski, Hypolito; Paterno, Aleksander

    2011-01-01

    This paper presents a benchmark for peak detection algorithms employed in fiber Bragg grating spectrometric interrogation systems. The accuracy, precision, and computational performance of currently used algorithms and those of a new proposed artificial neural network algorithm are compared. Centroid and gaussian fitting algorithms are shown to have the highest precision but produce systematic errors that depend on the FBG refractive index modulation profile. The proposed neural network displays relatively good precision with reduced systematic errors and improved computational performance when compared to other networks. Additionally, suitable algorithms may be chosen with the general guidelines presented. PMID:22163806

  11. Influence of the velocity vector base relocation to the center of mass of the interrogation area on PIV accuracy

    Directory of Open Access Journals (Sweden)

    Kouba Jan

    2014-03-01

    Full Text Available This paper is aimed at modification of calculation algorithm used in data processing from PIV (Particle Image Velocimetry method. The modification of standard Multi-step correlation algorithm is based on imaging the centre of mass of the interrogation area to define the initial point of the respective vector, instead of the geometrical centre. This paper describes the principle of initial point-vector assignment, the corresponding data processing methodology including the test track analysis. Both approaches are compared within the framework of accuracy in the conclusion. The accuracy test is performed using synthetic and real data.

  12. Fiber optic particle plasmon resonance sensor based on plasmonic light scattering interrogation

    International Nuclear Information System (INIS)

    Lin, H.Y.; Huang, C.H.; Chau, L.K.

    2012-01-01

    A highly sensitive fiber optic particle plasmon resonance sensor (FO-PPR) is demonstrated for label-free biochemical detection. The sensing strategy relies on interrogating the plasmonic scattering of light from gold nanoparticles on the optical fiber in response to the surrounding refractive index changes or molecular binding events. The refractive index resolution is estimated to be 3.8 x 10 -5 RIU. The limit of detection for anti-DNP antibody spiked in buffer is 1.2 x 10 -9 g/ml (5.3 pM) by using the DNP-functionalized FO-PPR sensor. The image processing of simultaneously recorded plasmonic scattering photographs at different compartments of the sensor is also demonstrated. Results suggest that the compact sensor can perform multiple independent measurements simultaneously by means of monitoring the plasmonic scattering intensity via photodiodes or a CCD. The potential of using a combination of different kinds of noble metal nanoparticles with different types of functionalized probes in multiple cascaded detection windows on a single fiber to become an inexpensive and ultrasensitive linear-array sensing platform for higher-throughput biochemical detection is provided. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  13. An Optogenetic Platform for Real-Time, Single-Cell Interrogation of Stochastic Transcriptional Regulation.

    Science.gov (United States)

    Rullan, Marc; Benzinger, Dirk; Schmidt, Gregor W; Milias-Argeitis, Andreas; Khammash, Mustafa

    2018-05-17

    Transcription is a highly regulated and inherently stochastic process. The complexity of signal transduction and gene regulation makes it challenging to analyze how the dynamic activity of transcriptional regulators affects stochastic transcription. By combining a fast-acting, photo-regulatable transcription factor with nascent RNA quantification in live cells and an experimental setup for precise spatiotemporal delivery of light inputs, we constructed a platform for the real-time, single-cell interrogation of transcription in Saccharomyces cerevisiae. We show that transcriptional activation and deactivation are fast and memoryless. By analyzing the temporal activity of individual cells, we found that transcription occurs in bursts, whose duration and timing are modulated by transcription factor activity. Using our platform, we regulated transcription via light-driven feedback loops at the single-cell level. Feedback markedly reduced cell-to-cell variability and led to qualitative differences in cellular transcriptional dynamics. Our platform establishes a flexible method for studying transcriptional dynamics in single cells. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  14. Motion Control and Optical Interrogation of a Levitating Single Nitrogen Vacancy in Vacuum.

    Science.gov (United States)

    Conangla, Gerard P; Schell, Andreas W; Rica, Raúl A; Quidant, Romain

    2018-05-24

    Levitation optomechanics exploits the unique mechanical properties of trapped nano-objects in vacuum to address some of the limitations of clamped nanomechanical resonators. In particular, its performance is foreseen to contribute to a better understanding of quantum decoherence at the mesoscopic scale as well as to lead to novel ultrasensitive sensing schemes. While most efforts have focused so far on the optical trapping of low-absorption silica particles, further opportunities arise from levitating objects with internal degrees of freedom, such as color centers. Nevertheless, inefficient heat dissipation at low pressures poses a challenge because most nano-objects, even with low-absorption materials, experience photodamage in an optical trap. Here, by using a Paul trap, we demonstrate levitation in vacuum and center-of-mass feedback cooling of a nanodiamond hosting a single nitrogen-vacancy center. The achieved level of motion control enables us to optically interrogate and characterize the emitter response. The developed platform is applicable to a wide range of other nano-objects and represents a promising step toward coupling internal and external degrees of freedom.

  15. Large scale meta-analysis of fragment-based screening campaigns: privileged fragments and complementary technologies.

    Science.gov (United States)

    Kutchukian, Peter S; Wassermann, Anne Mai; Lindvall, Mika K; Wright, S Kirk; Ottl, Johannes; Jacob, Jaison; Scheufler, Clemens; Marzinzik, Andreas; Brooijmans, Natasja; Glick, Meir

    2015-06-01

    A first step in fragment-based drug discovery (FBDD) often entails a fragment-based screen (FBS) to identify fragment "hits." However, the integration of conflicting results from orthogonal screens remains a challenge. Here we present a meta-analysis of 35 fragment-based campaigns at Novartis, which employed a generic 1400-fragment library against diverse target families using various biophysical and biochemical techniques. By statistically interrogating the multidimensional FBS data, we sought to investigate three questions: (1) What makes a fragment amenable for FBS? (2) How do hits from different fragment screening technologies and target classes compare with each other? (3) What is the best way to pair FBS assay technologies? In doing so, we identified substructures that were privileged for specific target classes, as well as fragments that were privileged for authentic activity against many targets. We also revealed some of the discrepancies between technologies. Finally, we uncovered a simple rule of thumb in screening strategy: when choosing two technologies for a campaign, pairing a biochemical and biophysical screen tends to yield the greatest coverage of authentic hits. © 2014 Society for Laboratory Automation and Screening.

  16. Monte carlo feasibility study of an active neutron assay technique for full-volume UF{sub 6} cylinder assay using a correlated interrogation source

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Karen A., E-mail: kamiller@lanl.gov [Los Alamos National Laboratory, Los Alamos, P.O. Box 1663 MS E540, NM 87545 (United States); Menlove, Howard O.; Swinhoe, Martyn T.; Marlow, Johnna B. [Los Alamos National Laboratory, Los Alamos, P.O. Box 1663 MS E540, NM 87545 (United States)

    2013-03-01

    Uranium cylinder assay plays an important role in the nuclear material accounting at gas centrifuge enrichment plants. The Passive Neutron Enrichment Meter (PNEM) was designed to determine uranium mass and enrichment in 30B and 48Y cylinders using total neutron and coincidence counting in the passive mode. 30B and 48Y cylinders are used to hold bulk UF{sub 6} feed, product, and tails at enrichment plants. In this paper, we report the results of a Monte-Carlo-based feasibility study for an active uranium cylinder assay system based on the PNEM design. There are many advantages of the active technique such as a shortened count time and a more direct measure of {sup 235}U content. The active system is based on a modified PNEM design and uses a {sup 252}Cf source as the correlated, active interrogation source. We show through comparison with a random AmLi source of equal strength how the use of a correlated driver significantly boosts the active signal and reduces the statistical uncertainty. We also discuss ways in which an active uranium cylinder assay system can be optimized to minimize background from {sup 238}U fast-neutron induced fission and direct counts from the interrogation source.

  17. Comparison of neutron and high-energy X-ray dual-beam radiography for air cargo inspection

    International Nuclear Information System (INIS)

    Liu, Y.; Sowerby, B.D.; Tickner, J.R.

    2008-01-01

    Dual-beam radiography techniques utilising various combinations of high-energy X-rays and neutrons are attractive for screening bulk cargo for contraband such as narcotics and explosives. Dual-beam radiography is an important enhancement to conventional single-beam X-ray radiography systems in that it provides additional information on the composition of the object being imaged. By comparing the attenuations of transmitted dual high-energy beams, it is possible to build a 2D image, colour coded to indicate material. Only high-energy X-rays, gamma-rays and neutrons have the required penetration to screen cargo containers. This paper reviews recent developments and applications of dual-beam radiography for air cargo inspection. These developments include dual high-energy X-ray techniques as well as fast neutron and gamma-ray (or X-ray) radiography systems. High-energy X-ray systems have the advantage of generally better penetration than neutron systems, depending on the material being interrogated. However, neutron systems have the advantage of much better sensitivity to material composition compared to dual high-energy X-ray techniques. In particular, fast neutron radiography offers the potential to discriminate between various classes of organic material, unlike dual energy X-ray techniques that realistically only offer the ability to discriminate between organic and metal objects

  18. Epistemic interrogatives in events anchored in the temporal anteriority

    Directory of Open Access Journals (Sweden)

    Vesela Chergova

    2012-12-01

    Full Text Available The present study attempts to analyse the epistemic modal functionality of temporal posteriority grammemes, referred to the “non-inactual plan”, i. e. the discourse plan measured directly from the moment of enunciation. In our opinion, the invariant category values of a verbal grameme predetermine the development of their complementary and contextual functions. Therefore, the analysis focuses also on the oppositional relations and neutralizations between the categories of verb tense, plan and perspective, on the temporal semantics and the aspectual values which maintain the oppositions between the nominal forms of the verb in accordance with the interpretation of verb categories proposed by Coseriu (1976. In this particular case, the complementary values which outline the scope of our interest fall into the parameters of the possibility and the probability (Veiga, 1991; Kitova-Vasileva, 2000, i.e. conjecture and conclusion in the field of epistemic semantics, yet with an orientation to the temporal anteriority epoch i.e. there is a conjecture regarding actions marked as prior to the moment of enunciation. The syntactic realisation of the epistemic values of conjecture is outlined in the sentence patterns of epistemic interrogatives of the type [Será que + V(P.P.S.] and [Ter(F.S. do Ind.+ V(Part.Pass.]. The study in this way goes beyond the semantic interpretation of the modal, temporal and aspectual values of the morphological instruments of conjecture, and follows the syntactic structure (the modus–dictum relations also in its discourse and pragmatic value.

  19. CVD polycrystalline diamond. A novel neutron detector and applications

    International Nuclear Information System (INIS)

    Mongkolnavin, R.

    1998-01-01

    Chemical Vapour Deposition (CVD) Polycrystalline Diamond film has been investigated as a low noise sensor for beta particles, gammas and neutrons using High Energy Physics technologies. Its advantages and disadvantages have been explored in comparison with other particle detectors such as silicon detector and other plastic scintillators. The performance and characteristic of the diamond detector have been fully studied and discussed. These studies will lead to a better understanding of how CVD diamonds perform as a detector and how to improve their performance under various conditions. A CVD diamond detector model has been proposed which is an attempt to explain the behaviour of such an extreme detector material. A novel neutron detector is introduced as a result of these studies. A good thermal and fast neutron detector can be fabricated with CVD diamond with new topologies. This detector will perform well without degradation in a high neutron radiation environment, as diamond is known to be radiation hard. It also offers better neutrons and gammas discrimination for high gamma background applications compared to other semiconductor detectors. A full simulation of the detector has also been done using GEANT, a Monte-Carlo simulation program for particle detectors. Simulation results show that CVD diamond detectors with this novel topology can detect neutrons with great directionality. Experimental work has been done on this detector in a nuclear reactor environment and accelerator source. A novel neutron source which offers a fast pulse high-energy neutrons has also been studied. With this detector, applications in neutron spectrometer for low-Z material have been pursued with various neutron detection techniques. One of these is a low-Z material identification system. The system has been designed and simulated for contraband luggage interrogation using the detector and the novel neutron source. Also other neutron related applications have been suggested. (author)

  20. CVD polycrystalline diamond. A novel neutron detector and applications

    International Nuclear Information System (INIS)

    Mongkolnavin, R.

    1998-07-01

    Chemical Vapour Deposition (CVD) Polycrystalline Diamond film has been investigated as a low noise sensor for beta particles, gammas and neutrons using High Energy Physics technologies. Its advantages and disadvantages have been explored in comparison with other particle detectors such as silicon detector and other plastic scintillators. The performance and characteristic of the diamond detector have been fully studied and discussed. These studies will lead to a better understanding of how CVD diamonds perform as a detector and how to improve their performance under various conditions. A CVD diamond detector model has been proposed which is an attempt to explain the behaviour of such an extreme detector material. A novel neutron detector is introduced as a result of these studies. A good thermal and fast neutron detector can be fabricated with CVD diamond with new topologies. This detector will perform well without degradation in a high neutron radiation environment, as diamond is known to be radiation-hard. It also offers better neutrons and gammas discrimination for high gamma background applications compared to other semiconductor detectors. A full simulation of the detector has also been done using GEANT, a Monte Carlo simulation program for particle detectors. Simulation results show that CVD diamond detectors with this novel topology can detect neutrons with great directionality. Experimental work has been done on this detector in a nuclear reactor environment and accelerator source. A novel neutron source which offers a fast pulse high-energy neutrons has also been studied. With this detector, applications in neutron spectrometry for low-Z material have been pursued with various neutron detection techniques. One of these is a low-Z material identification system. The system has been designed and simulated for contraband luggage interrogation using the detector and the novel neutron source. (author)

  1. MEMS Fabry-Perot sensor interrogated by optical system-on-a-chip for simultaneous pressure and temperature sensing.

    Science.gov (United States)

    Pang, Cheng; Bae, Hyungdae; Gupta, Ashwani; Bryden, Kenneth; Yu, Miao

    2013-09-23

    We present a micro-electro-mechanical systems (MEMS) based Fabry-Perot (FP) sensor along with an optical system-on-a-chip (SOC) interrogator for simultaneous pressure and temperature sensing. The sensor employs a simple structure with an air-backed silicon membrane cross-axially bonded to a 45° polished optical fiber. This structure renders two cascaded FP cavities, enabling simultaneous pressure and temperature sensing in close proximity along the optical axis. The optical SOC consists of a broadband source, a MEMS FP tunable filter, a photodetector, and the supporting circuitry, serving as a miniature spectrometer for retrieving the two FP cavity lengths. Within the measured pressure and temperature ranges, experimental results demonstrate that the sensor exhibits a good linear response to external pressure and temperature changes.

  2. Combined Proteomic and Transcriptomic Interrogation of the Venom Gland of Conus geographus Uncovers Novel Components and Functional Compartmentalization*

    Science.gov (United States)

    Safavi-Hemami, Helena; Hu, Hao; Gorasia, Dhana G.; Bandyopadhyay, Pradip K.; Veith, Paul D.; Young, Neil D.; Reynolds, Eric C.; Yandell, Mark; Olivera, Baldomero M.; Purcell, Anthony W.

    2014-01-01

    Cone snails are highly successful marine predators that use complex venoms to capture prey. At any given time, hundreds of toxins (conotoxins) are synthesized in the secretory epithelial cells of the venom gland, a long and convoluted organ that can measure 4 times the length of the snail's body. In recent years a number of studies have begun to unveil the transcriptomic, proteomic and peptidomic complexity of the venom and venom glands of a number of cone snail species. By using a combination of DIGE, bottom-up proteomics and next-generation transcriptome sequencing the present study identifies proteins involved in envenomation and conotoxin maturation, significantly extending the repertoire of known (poly)peptides expressed in the venom gland of these remarkable animals. We interrogate the molecular and proteomic composition of different sections of the venom glands of 3 specimens of the fish hunter Conus geographus and demonstrate regional variations in gene expression and protein abundance. DIGE analysis identified 1204 gel spots of which 157 showed significant regional differences in abundance as determined by biological variation analysis. Proteomic interrogation identified 342 unique proteins including those that exhibited greatest fold change. The majority of these proteins also exhibited significant changes in their mRNA expression levels validating the reliability of the experimental approach. Transcriptome sequencing further revealed a yet unknown genetic diversity of several venom gland components. Interestingly, abundant proteins that potentially form part of the injected venom mixture, such as echotoxins, phospholipase A2 and con-ikots-ikots, classified into distinct expression clusters with expression peaking in different parts of the gland. Our findings significantly enhance the known repertoire of venom gland polypeptides and provide molecular and biochemical evidence for the compartmentalization of this organ into distinct functional entities

  3. Real-time observation of DNA target interrogation and product release by the RNA-guided endonuclease CRISPR Cpf1 (Cas12a).

    Science.gov (United States)

    Singh, Digvijay; Mallon, John; Poddar, Anustup; Wang, Yanbo; Tippana, Ramreddy; Yang, Olivia; Bailey, Scott; Ha, Taekjip

    2018-05-22

    CRISPR-Cas9, which imparts adaptive immunity against foreign genomic invaders in certain prokaryotes, has been repurposed for genome-engineering applications. More recently, another RNA-guided CRISPR endonuclease called Cpf1 (also known as Cas12a) was identified and is also being repurposed. Little is known about the kinetics and mechanism of Cpf1 DNA interaction and how sequence mismatches between the DNA target and guide-RNA influence this interaction. We used single-molecule fluorescence analysis and biochemical assays to characterize DNA interrogation, cleavage, and product release by three Cpf1 orthologs. Our Cpf1 data are consistent with the DNA interrogation mechanism proposed for Cas9. They both bind any DNA in search of protospacer-adjacent motif (PAM) sequences, verify the target sequence directionally from the PAM-proximal end, and rapidly reject any targets that lack a PAM or that are poorly matched with the guide-RNA. Unlike Cas9, which requires 9 bp for stable binding and ∼16 bp for cleavage, Cpf1 requires an ∼17-bp sequence match for both stable binding and cleavage. Unlike Cas9, which does not release the DNA cleavage products, Cpf1 rapidly releases the PAM-distal cleavage product, but not the PAM-proximal product. Solution pH, reducing conditions, and 5' guanine in guide-RNA differentially affected different Cpf1 orthologs. Our findings have important implications on Cpf1-based genome engineering and manipulation applications.

  4. Confirmatory measurements of UF6 using the neutron self-interrogation method

    International Nuclear Information System (INIS)

    Stewart, J.E.; Ensslin, N.; Menlove, H.O.; Cowder, L.R.; Polk, P.J.

    1985-01-01

    A passive neutron counting method has been developed for measurement of the 235 U mass in Model 5A cylinders of UF 6 . The unique neutronic properties of UF 6 containing highly enriched uranium (HEU) permit 235 U assay using only passive neutron counting. The sample effectively assays itself by self-interrogation. Shipped from enrichment plants and received at fuel fabrication and conversion facilities, 5A UF 6 cylinders hold up to approx.17 kg of 235 U each. Field measurements at the Portsmouth Gaseous Diffusion Plant (GDP) showed an average assay accuracy of 6.8% (1sigma) for 44 cylinders with enrichments from 6 to 98% and with a range of fill heights. Further measurements on 38 cylinders containing 97%-enriched material yielded an accuracy of 2.8% (1sigma). Typical counting times for these measurements were less than 5 min. An in-plant instrument for receipts confirmation measurements of 5A UF 6 cylinders has been developed for the Savannah River Plant. The Receipts Assay Monitor (RAM) is currently being tested and calibrated. It is designed to confirm declared fissile mass in all incoming 5A cylinders containing HEU in the form of UF 6 . One of the computer-controlled features is a removable cadmium liner for the sample cavity. The liner allows a sample fill-height correction, which significantly improves assay accuracy

  5. Assay of fissionable isotopes in aqueous solution by pulsed neutron interrogation

    International Nuclear Information System (INIS)

    Campbell, P.; Gardy, E.M.; Boase, D.G.

    1978-04-01

    Non-destructive assay of uranium-235 and thorium-232 in aqueous nitric acid solutions has been accomplished by irradiation with pulses of neutrons from a 14-MeV Cockcroft-Walton neutron generator, and counting of the delayed neutrons emitted from the fissions induced. Design of the delayed neutron detector assemblies is described, together with the neutron pulse timing and counting systems. The effects of irradiation time, counting time, neutron moderation, detector design and sample geometry on the delayed neutron response from uranium-235 and 238 and thorium-232 are discussed. By using polyethylene to moderate the interrogating neutrons, solutions can be analyzed for both uranium-235 and thorium. Comparative analyses with chemical and γ-spectrometric methods show good agreement. The neutron method is rapid and is shown to be unaffected by the presence in solution of impurities such as iron, nickel, chromium, and aluminum. With the experimental equipment described, detection limits of 0.6 mg of 235 U and 9 mg of 232 Th in a sample volume of 25 mL have been achieved. Analyses of highly radioactive samples may be done easily since the measurements are not affected by the presence of large amounts of βγ radiation. Samples can be enclosed in small lead-shielded flasks during analysis to protect the analyst. The potential of the technique to on-line analysis applications is explored briefly. (author)

  6. Lessons Learned In Developing The VACIS Products

    International Nuclear Information System (INIS)

    Orphan, Victor J.

    2011-01-01

    SAIC's development of VACIS provides useful 'lessons learned' in bridging the gap from an idea to a security or contraband detection product. From a gamma densitometer idea for solving a specific Customs Service (CS) requirement (detection of drugs in near-empty tanker trucks) in mid-1990's, SAIC developed a broad line of vehicle and cargo inspections systems (over 500 systems deployed to date) based on a gamma-ray radiographic imaging technique. This paper analyzes the reasons for the successful development of VACIS and attempts to identify ''lessons learned'' useful for future security and contraband detection product developments.

  7. 78 FR 36469 - Promoting Technological Solutions to Combat Contraband Wireless Device Use in Correctional...

    Science.gov (United States)

    2013-06-18

    ... receiving antennas, cable television equipment, GPS equipment, pagers, cellular phones, mobile... requests specific comment regarding costs and benefits. Streamlining Authorization of Leases for Managed... managed access lessee typically seeks to modify its regulatory status from commercial mobile radio service...

  8. Future technology challenges in non-proliferation

    International Nuclear Information System (INIS)

    Richardson, J.H.

    2004-01-01

    Radiation detection technologies are an important tool in the prevention of proliferation. A variety of new developments have enabled enhanced performance in terms of energy resolution, spatial resolution, predictive modeling and simulation, active interrogation, and ease of operation and deployment in the field. For example, various gamma ray imaging approaches are being explored to combine spatial resolution with background suppression in order to enhance sensitivity at reasonable standoff distances and acquisition times. New materials and approaches are being developed in order to provide adequate energy resolution in field use without the necessity for liquid nitrogen. Finally, different detectors combined into distributed networks offer promise for detection and tracking of radioactive materials. As the world moves into the 21st century, the possibility of greater reliance on nuclear energy will impose additional technical requirements to prevent proliferation. In addition to proliferation resistant reactors, a careful examination of the various possible fuel cycles from cradle to grave will provide additional technical and nonproliferation challenges in the areas of conversion, enrichment, transportation, recycling and waste disposal. Radiation detection technology and information management have a prominent role in any future global regime for nonproliferation beyond the current Advanced Protocol. This work was performed under the auspices of the U.S. Department of Energy by University of California, Lawrence Livermore National Laboratory under contract No. W-7405-Eng-48. (author)

  9. Interrogating Key Positions of Size-Reduced TALE Repeats Reveals a Programmable Sensor of 5-Carboxylcytosine.

    Science.gov (United States)

    Maurer, Sara; Giess, Mario; Koch, Oliver; Summerer, Daniel

    2016-12-16

    Transcription-activator-like effector (TALE) proteins consist of concatenated repeats that recognize consecutive canonical nucleobases of DNA via the major groove in a programmable fashion. Since this groove displays unique chemical information for the four human epigenetic cytosine nucleobases, TALE repeats with epigenetic selectivity can be engineered, with potential to establish receptors for the programmable decoding of all human nucleobases. TALE repeats recognize nucleobases via key amino acids in a structurally conserved loop whose backbone is positioned very close to the cytosine 5-carbon. This complicates the engineering of selectivities for large 5-substituents. To interrogate a more promising structural space, we engineered size-reduced repeat loops, performed saturation mutagenesis of key positions, and screened a total of 200 repeat-nucleobase interactions for new selectivities. This provided insight into the structural requirements of TALE repeats for affinity and selectivity, revealed repeats with improved or relaxed selectivity, and resulted in the first selective sensor of 5-carboxylcytosine.

  10. Model of a Plasmonic Phase Interrogation Probe for Optical Sensing of Hemoglobin in Blood Samples

    Science.gov (United States)

    Sharma, Anuj K.

    2015-11-01

    Phase interrogation based surface plasmon resonance (SPR) biosensor is proposed for the determination of Hb concentration. Previous experimental results describing variation of refractive index of human blood with Hb concentration at different wavelengths are considered for design simulations. The biosensor design with silica substrate and gold layer is considered. The sensor's performance is closely analyzed in terms of phase sensitivity and resolution. The influence of operating wavelength on biosensor's performance for Hb measurement is critically investigated, which points to carry out the Hb measurement at a shorter wavelength as phase sensitivity and resolution increase significantly with decrease in wavelength. The results are explained in terms of suitable physical concepts such as radiation damping. Use of contamination-preventing biochemical layer ascertains the stability of measurement with the intended SPR biosensor probe. The simulation results also highlight that the resolution of Hb measurement achievable with the proposed biosensor is much higher compared with several existing methods.

  11. Study and development of a method allowing the identification of actinides inside nuclear waste packages, by active neutron or photon interrogation and delayed gamma-ray spectrometry; Etude et developpement d'une technique de dosage des actinides dans les colis de dechets radioactifs par interrogation photonique ou neutronique active et spectrometrie des gamma retardes

    Energy Technology Data Exchange (ETDEWEB)

    Carrel, F

    2007-10-15

    An accurate estimation of the alpha-activity of a nuclear waste package is necessary to select the best mode of storage. The main purpose of this work is to develop a non-destructive active method, based on the fission process and allowing the identification of actinides ({sup 235}U, {sup 238}U, {sup 239}Pu). These three elements are the main alpha emitters contained inside a package. Our technique is based on the detection of delayed gammas emitted by fission products. These latter are created by irradiation with the help of a neutron or photon beam. Performances of this method have been investigated after an Active Photon or Neutron Interrogation (INA or IPA). Three main objectives were fixed in the framework of this thesis. First, we measured many yields of photofission products to compensate the lack of data in the literature. Then, we studied experimental performances of this method to identify a given actinide ({sup 239}Pu in fission, {sup 235}U in photofission) present in an irradiated mixture. Finally, we assessed the application of this technique on different mock-up packages for both types of interrogation (118 l mock-up package containing EVA in fission, 220 l mock-up package with a wall of concrete in photofission). (author)

  12. Survey of Neutron Generators for Active Interrogation

    Energy Technology Data Exchange (ETDEWEB)

    Moss, Calvin Elroy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Myers, William L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Sundby, Gary M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Chichester, David L. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Johnson, James P. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-05-02

    Some of these commercially available generators meet all of the requirements in Table 1, but there are other concerns. Most generators containing SF6 will be required to have the SF6 gas removed for shipping because of DOT regulations. However, Thermo Fisher has a DOT exemption. The P211 and B211 from Thermo Fisher meet the requirements listed in Table 1, but they are old designs and are no longer offered for sale. Also, they require 15 minutes or more of warmup before neutron output is available, and they lack a modern digital control. The nGen-300C from Starfire Industries is interesting because it is a portable system, but it uses the DD reaction for 2.5 MeV neutrons, which are not as penetrating as the 14 MeV neutrons from the DT reaction. The MP 320 from Thermo Fisher is another portable system, but the minimum pulse rate is 250 Hz, which is too fast for measurement of delayed neutrons and re-interrogation by delayed neutrons between pulses. The Genie 16 from Sodern (from France) probably meets the requirements, but the required power is probably too high for battery operation. The generators from Russia and China may be difficult to purchase, and service may not be available. The power required by some of these generators is low enough that batteries can be used. The portable units, nGen-300C and the MP320, could easily be operated with batteries. Other generators with low power requirements, as specified in the above vendors list, could possibly be operated with reason size batteries. The batteries do not need to be internal to the generator, but can be in a separate package. The availability of high capacity lithium batteries with sophisticated safety circuits makes battery operation more possible now than when lead acid batteries were used. The best path forward probably requires working with vendors of the existing systems. If Starfire Industries could be persuaded to put tritium in their nGen-300C generator, possibly in collaboration with a national

  13. Using Technology to Improve the Objectivity of Criminal Responsibility Evaluations.

    Science.gov (United States)

    Vitacco, Michael J; Gottfried, Emily D; Batastini, Ashley B

    2018-03-01

    Criminal responsibility (or insanity) evaluations require forensic clinicians to reconstruct a defendant's decision-making abilities, behavioral control, and emotional state at the time of the criminal act. Forensic evaluators are ultimately tasked to evaluate whether an individual had the capacity to understand right from wrong, and in some jurisdictions, determine whether the defendant lacked substantial capacity to conform his behavior to the requirements of the law as a result of a threshold condition (e.g., mental illness). Insanity evaluations are inherently complex, because they require the clinician to determine someone's mental state at some point in the past (weeks, months, or even years). Recent research on insanity evaluations underscores significant problems with the reliability and validity of these evaluations. However, technological advances including social media (e.g., Facebook and Twitter), mandating that law enforcement videotape interrogations, and the use of body and dashboard cameras can aid clinicians in improving the precision and quality of insanity evaluations. This article discusses practical guidelines and ethics-related concerns regarding the use of technology to improve the objectivity of criminal responsibility evaluations. © 2018 American Academy of Psychiatry and the Law.

  14. The interrogative particle zar - from syntax and semantics to etymology

    Directory of Open Access Journals (Sweden)

    Vlajić-Popović Jasna B.

    2016-01-01

    Full Text Available This paper deals with the Serbian interrogative particle zar/zar/zar ‘num, forsan’, typically positioned at the beginning of a sentence (expressing surprise, wonder, disbelief, dissent, etc. or at its end, coupled with ne and separated by a comma (in guided questions, affirmative and negative alike: Ti ga (ne voliš, zar ne?, yet also broadly attested in obsolete use (in the 19-20th-century literature in modal function, where it is synonymous to valjda, možda ‘perhaps, maybe’. After a review of the ways zar is treated in modern Serbian grammars and descriptive dictionaries (including several dialectal dictionaries, and following research of Macedonian, Bulgarian and Turkish dictionaries, its etymology is discussed: Skok’s unconvincing idioglottal interpretation is refuted, and Rešetar’s idea is reintroduced (prevoiusly rejected by Skok, questioned by Elezović, accepted in the RJA that zar, along with its obliterated forms zaer, zajer, zaher, should be traced back to Turkish zahir adv. ‘apparently, clearly, evidently’, ‘seemingly, perhaps, maybe’. The semantic-syntactic evolution of the loanword within the Serbian language is illustrated, and hence the alloglottal etymology corroborated, by a selection of quotes from folklore and eminent 19-20th-century writers. And finally, as the most likely, the paper offers the interpretation of this particle as a hybrid formation resulting from contamination by the Turkisms of an idioglottal zar, which could be related to archaic Polish zaż < PSl. *za-že. [Projekat Ministarstva nauke Republike Srbije, br. 178007: Etimološka istraživanja srpskog jezika i izrada Etimološkog rečnika srpskog jezika

  15. Improved Technology To Prevent Nuclear Proliferation And Counter Nuclear Terrorism

    Energy Technology Data Exchange (ETDEWEB)

    Richardson, J; Yuldashev, B; Labov, S; Knapp, R

    2006-06-12

    As the world moves into the 21st century, the possibility of greater reliance on nuclear energy will impose additional technical requirements to prevent proliferation. In addition to proliferation resistant reactors, a careful examination of the various possible fuel cycles from cradle to grave will provide additional technical and nonproliferation challenges in the areas of conversion, enrichment, transportation, recycling and waste disposal. Radiation detection technology and information management have a prominent role in any future global regime for nonproliferation. As nuclear energy and hence nuclear materials become an increasingly global phenomenon, using local technologies and capabilities facilitate incorporation of enhanced monitoring and detection on the regional level. Radiation detection technologies are an important tool in the prevention of proliferation and countering radiological/nuclear terrorism. A variety of new developments have enabled enhanced performance in terms of energy resolution, spatial resolution, passive detection, predictive modeling and simulation, active interrogation, and ease of operation and deployment in the field. For example, various gamma ray imaging approaches are being explored to combine spatial resolution with background suppression in order to enhance sensitivity many-fold at reasonable standoff distances and acquisition times. New materials and approaches are being developed in order to provide adequate energy resolution in field use without the necessity for liquid nitrogen. Different detection algorithms enable fissile materials to be distinguished from other radioisotopes.

  16. Phase space interrogation of the empirical response modes for seismically excited structures

    Science.gov (United States)

    Paul, Bibhas; George, Riya C.; Mishra, Sudib K.

    2017-07-01

    Conventional Phase Space Interrogation (PSI) for structural damage assessment relies on exciting the structure with low dimensional chaotic waveform, thereby, significantly limiting their applicability to large structures. The PSI technique is presently extended for structure subjected to seismic excitations. The high dimensionality of the phase space for seismic response(s) are overcome by the Empirical Mode Decomposition (EMD), decomposing the responses to a number of intrinsic low dimensional oscillatory modes, referred as Intrinsic Mode Functions (IMFs). Along with their low dimensionality, a few IMFs, retain sufficient information of the system dynamics to reflect the damage induced changes. The mutually conflicting nature of low-dimensionality and the sufficiency of dynamic information are taken care by the optimal choice of the IMF(s), which is shown to be the third/fourth IMFs. The optimal IMF(s) are employed for the reconstruction of the Phase space attractor following Taken's embedding theorem. The widely referred Changes in Phase Space Topology (CPST) feature is then employed on these Phase portrait(s) to derive the damage sensitive feature, referred as the CPST of the IMFs (CPST-IMF). The legitimacy of the CPST-IMF is established as a damage sensitive feature by assessing its variation with a number of damage scenarios benchmarked in the IASC-ASCE building. The damage localization capability, remarkable tolerance to noise contamination and the robustness under different seismic excitations of the feature are demonstrated.

  17. Noninvasive Interrogation of DLL3 Expression in Metastatic Small Cell Lung Cancer.

    Science.gov (United States)

    Sharma, Sai Kiran; Pourat, Jacob; Abdel-Atti, Dalya; Carlin, Sean D; Piersigilli, Alessandra; Bankovich, Alexander J; Gardner, Eric E; Hamdy, Omar; Isse, Kumiko; Bheddah, Sheila; Sandoval, Joseph; Cunanan, Kristen M; Johansen, Eric B; Allaj, Viola; Sisodiya, Vikram; Liu, David; Zeglis, Brian M; Rudin, Charles M; Dylla, Scott J; Poirier, John T; Lewis, Jason S

    2017-07-15

    The Notch ligand DLL3 has emerged as a novel therapeutic target expressed in small cell lung cancer (SCLC) and high-grade neuroendocrine carcinomas. Rovalpituzumab teserine (Rova-T; SC16LD6.5) is a first-in-class DLL3-targeted antibody-drug conjugate with encouraging initial safety and efficacy profiles in SCLC in the clinic. Here we demonstrate that tumor expression of DLL3, although orders of magnitude lower in surface protein expression than typical oncology targets of immunoPET, can serve as an imaging biomarker for SCLC. We developed 89 Zr-labeled SC16 antibody as a companion diagnostic agent to facilitate selection of patients for treatment with Rova-T based on a noninvasive interrogation of the in vivo status of DLL3 expression using PET imaging. Despite low cell-surface abundance of DLL3, immunoPET imaging with 89 Zr-labeled SC16 antibody enabled delineation of subcutaneous and orthotopic SCLC tumor xenografts as well as distant organ metastases with high sensitivity. Uptake of the radiotracer in tumors was concordant with levels of DLL3 expression and, most notably, DLL3 immunoPET yielded rank-order correlation for response to SC16LD6.5 therapy in SCLC patient-derived xenograft models. Cancer Res; 77(14); 3931-41. ©2017 AACR . ©2017 American Association for Cancer Research.

  18. Methods for Characterization of Batteries Using Acoustic Interrogation

    Science.gov (United States)

    Bhadra, Shoham

    Batteries are a ubiquitous form of electrochemical energy storage, but thus far the methods for measuring the mechanical properties of batteries and their component materials in operando have lagged far behind the methods for measuring the corresponding electrical properties. In this thesis, I demonstrate methods for determining the changes in materials properties of an electrochemical energy storage cell both ex situ and in operando.. I begin by establishing the impact of micro-scale morphology changes on the macro-scale dynamic mechanical response in commercial alkaline AA cells. Using a bounce test, the coefficient of restitution (COR) of the cell is shown to increase non-linearly as a function of state of charge (SOC). I show that the reason for the increase in the COR stems from the spatially-dependent oxidation of the Zn anode, with an initial increase corresponding to the formation of a percolation pathway of ZnO-clad Zn particles spanning the radius of the anode. The subsequent saturation of the COR is shown to result from the ultimate solidification and desiccation of the Zn anode. Building from this, I present a generalized in operando solution for materials characterization in batteries using ultrasonic interrogation. The materials properties of battery components change during charge and discharge, resulting in a change in the sound speed of the materials. By attaching transducers to a battery during cycling and sending ultrasonic pulses through each cell I observe the changes in the time of flight (ToF) of the pulses, both in reflection and transmission. I show that the changes in ToF correspond to both SOC and state of health (SOH) in a variety of battery chemistries and geometries, and detail a corresponding acoustic conservation law model framework. Finally, I perform these electrochemical acoustic time of flight (EAToF) experiments on commercial alkaline AA cells. By correlating the results with energy dispersive x-ray diffraction (EDXRD) data and

  19. Integrated Performance Testing Workshop, Modules 6 - 11

    Energy Technology Data Exchange (ETDEWEB)

    Leach, Janice; Torres, Teresa M.

    2012-10-01

    These modules cover performance testing of: Interior Detection Systems; Access Controls; Exterior Detection Systems; Video Assessment Systems; SNM / Contraband Detection Systems; Access Delay Elements

  20. Study and development of a method allowing the identification of actinides inside nuclear waste packages, by active neutron or photon interrogation and delayed gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Carrel, F.

    2007-10-01

    An accurate estimation of the alpha-activity of a nuclear waste package is necessary to select the best mode of storage. The main purpose of this work is to develop a non-destructive active method, based on the fission process and allowing the identification of actinides ( 235 U, 238 U, 239 Pu). These three elements are the main alpha emitters contained inside a package. Our technique is based on the detection of delayed gammas emitted by fission products. These latter are created by irradiation with the help of a neutron or photon beam. Performances of this method have been investigated after an Active Photon or Neutron Interrogation (INA or IPA). Three main objectives were fixed in the framework of this thesis. First, we measured many yields of photofission products to compensate the lack of data in the literature. Then, we studied experimental performances of this method to identify a given actinide ( 239 Pu in fission, 235 U in photofission) present in an irradiated mixture. Finally, we assessed the application of this technique on different mock-up packages for both types of interrogation (118 l mock-up package containing EVA in fission, 220 l mock-up package with a wall of concrete in photofission). (author)