WorldWideScience

Sample records for contoured prefabricated foot

  1. Comparison of plantar pressure distribution in CAD-CAM and prefabricated foot orthoses in patients with flexible flatfeet.

    Science.gov (United States)

    Khodaei, Banafsheh; Saeedi, Hassan; Jalali, Maryam; Farzadi, Maede; Norouzi, Ehsan

    2017-12-01

    The effect of foot orthoses on plantar pressure distribution has been proven by researchers but there are some controversies about advantages of custom-made foot orthoses to less expensive prefabricated foot orthoses. Nineteen flatfeet adults between 18 and 45 participated in this study. CAD-CAM foot orthoses were made for these patients according to their foot scan. Prefabricated foot orthoses were prepared according to their foot size. Plantar pressure, force and contact area were measured using pedar ® -x in-shoe system wearing shoe alone, wearing CAD-CAM foot orthoses and wearing prefabricated foot orthoses. Repeated measures ANOVA model with post-hoc, Bonferroni comparison were used to test differences. CAD-CAM and prefabricated foot orthoses both decreased pressure and force under 2nd, 3-5 metatarsal and heel regions comparing to shoe alone condition. CAD-CAM foot orthosis increased pressure under lateral toe region in comparison to shoe alone and prefabricated foot orthosis. Both foot orthoses increased pressure and contact area in medial midfoot region comparing to shoe alone condition. Increased forces were seen at hallux and lateral toes by prefabricated foot orthoses in comparison with CAD-CAM foot orthoses and control condition, respectively. According to the results, both foot orthoses could decrease the pressure under heel and metatarsal area. It seems that the special design of CAD-CAM foot orthoses could not make great differences in plantar pressure distribution in this sample. Further research is required to determine whether these results are associated with different scan systems or design software. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. CHANGES IN PATELLOFEMORAL JOINT STRESS DURING RUNNING WITH THE APPLICATION OF A PREFABRICATED FOOT ORTHOTIC.

    Science.gov (United States)

    Almonroeder, Thomas G; Benson, Lauren C; O'Connor, Kristian M

    2015-12-01

    Foot orthotics are commonly utilized in the treatment of patellofemoral pain (PFP) and have shown clinical benefit; however, their mechanism of action remains unclear. Patellofemoral joint stress (PFJS) is thought to be one of the main etiological factors associated with PFP. The primary purpose of this study was to investigate the effects of a prefabricated foot orthotic with 5 ° of medial rearfoot wedging on the magnitude and the timing of the peak PFJS in a group of healthy female recreational athletes. The hypothesis was that there would be significant reduction in the peak patellofemoral joint stress and a delay in the timing of this peak in the orthotic condition. Cross-sectional. Kinematic and kinetic data were collected during running trials in a group of healthy, female recreational athletes. The knee angle and moment data in the sagittal plane were incorporated into a previously developed model to estimate patellofemoral joint stress. The dependent variables of interest were the peak patellofemoral joint stress as well as the percentage of stance at which this peak occurred, as both the magnitude and the timing of the joint loading are thought to be important in overuse running injuries. The peak patellofemoral joint stress significantly increased in the orthotic condition by 5.8% (p=.02, ES=0.24), which does not support the initial hypothesis. However, the orthotic did significantly delay the timing of the peak during the stance phase by 3.8% (p=.002, ES=0.47). The finding that the peak patellofemoral joint stress increased in the orthotic condition did not support the initial hypothesis. However, the finding that the timing of this peak was delayed to later in the stance phase in the orthotic condition did support the initial hypothesis and may be related to the clinical improvements previously reported in subjects with PFP. Level 4.

  3. Predictors of response to prefabricated foot orthoses or rocker-sole footwear in individuals with first metatarsophalangeal joint osteoarthritis.

    Science.gov (United States)

    Menz, Hylton B; Auhl, Maria; Tan, Jade M; Levinger, Pazit; Roddy, Edward; Munteanu, Shannon E

    2017-05-12

    Osteoarthritis of the first metatarsophalangeal joint (1st MTPJ OA) is a common and disabling condition commonly managed with footwear and orthotic interventions. The objective of this study was to identify factors associated with a successful treatment response in people with 1st MTPJ OA provided with prefabricated orthoses or rocker-sole footwear as part of a randomised clinical trial. People with 1st MTPJ OA (n = 88) who participated in a randomised trial were allocated to receive prefabricated foot orthoses (n = 47) or rocker-sole footwear (n = 41) and completed a baseline questionnaire including information on demographics, anthropometrics, general health, pain characteristics (including the Foot Health Status Questionnaire [FHSQ] and Foot Function Index [FFI]) and perceptions of the interventions, and a clinical assessment of foot posture, range of motion, radiographic severity and in-shoe plantar pressures. Adherence was documented using diaries. At 12 weeks, participants documented their perception of improvement on a 15-point scale. Those reporting at least moderate improvement on this scale were classified as 'responders'. There were 29 responders (62%) in the orthoses group and 16 responders (39%) in the rocker-sole group. In the orthoses group, responders had greater baseline pain severity while walking, a higher FFI difficulty score, and wore their orthoses more frequently. In the rocker-sole group, responders had a higher FFI stiffness score and greater radiographic severity. However, the accuracy of these variables in identifying responders in each group was modest (62 and 53%, respectively). The response to prefabricated orthoses or rocker-sole footwear in people with 1st MTPJ OA is related to measures of increased pain and disease severity. However, the overall classification accuracy associated with these factors is not sufficient for identifying individuals who are most likely to benefit from these interventions. Australian New

  4. Biomechanical Effects of Prefabricated Foot Orthoses and Rocker‐Sole Footwear in Individuals With First Metatarsophalangeal Joint Osteoarthritis

    Science.gov (United States)

    Auhl, Maria; Tan, Jade M.; Levinger, Pazit; Roddy, Edward; Munteanu, Shannon E.

    2016-01-01

    Objective To evaluate the effects of prefabricated foot orthoses and rocker‐sole footwear on spatiotemporal parameters, hip and knee kinematics, and plantar pressures in people with first metatarsophalangeal (MTP) joint osteoarthritis (OA). Methods. A total of 102 people with first MTP joint OA were randomly allocated to receive prefabricated foot orthoses or rocker‐sole footwear. The immediate biomechanical effects of the interventions (compared to usual footwear) were examined using a wearable sensor motion analysis system and an in‐shoe plantar pressure measurement system. Results Spatiotemporal/kinematic and plantar pressure data were available from 88 and 87 participants, respectively. The orthoses had minimal effect on spatiotemporal or kinematic parameters, while the rocker‐sole footwear resulted in reduced cadence, percentage of the gait cycle spent in stance phase, and sagittal plane hip range of motion. The orthoses increased peak pressure under the midfoot and lesser toes. Both interventions significantly reduced peak pressure under the first MTP joint, and the rocker‐sole shoes also reduced peak pressure under the second through fifth MTP joints and heel. When the effects of the orthoses and rocker‐sole shoes were directly compared, there was no difference in peak pressure under the hallux, first MTP joint, or heel; however, the rocker‐sole shoes exhibited lower peak pressure under the lesser toes, second through fifth MTP joints, and midfoot. Conclusion Prefabricated foot orthoses and rocker‐sole footwear are effective at reducing peak pressure under the first MTP joint in people with first MTP joint OA, but achieve this through different mechanisms. Further research is required to determine whether these biomechanical changes result in improvements in symptoms. PMID:26640157

  5. A protocol for a randomised controlled trial of prefabricated versus customised foot orthoses for people with rheumatoid arthritis: the FOCOS RA trial [Foot Orthoses - Customised v Off-the-Shelf in Rheumatoid Arthritis].

    Science.gov (United States)

    Gallagher, Kellie S; Godwin, Jon; Hendry, Gordon J; Steultjens, Martijn; Woodburn, Jim

    2018-01-01

    Foot pain is common in rheumatoid arthritis and appears to persist despite modern day medical management. Several clinical practice guidelines currently recommend the use of foot orthoses for the treatment of foot pain in people with rheumatoid arthritis. However, an evidence gap currently exists concerning the comparative clinical- and cost-effectiveness of prefabricated and customised foot orthoses in people with early rheumatoid arthritis. Early intervention with orthotics may offer the best opportunity for positive therapeutic outcomes. The primary aim of this study is to evaluate the comparative clinical- and cost-effectiveness of prefabricated versus customised orthoses for reducing foot pain over 12 months. This is a multi-centre two-arm parallel randomised controlled trial comparing prefabricated versus customised orthoses in participants with early rheumatoid arthritis (rheumatoid arthritis, global functional status via the Stanford Health Assessment Questionnaire, foot disease activity via the Rheumatoid Arthritis Foot Disease Activity Index, and health-related quality of life at baseline, 6 and 12 months. Process outcomes will include recruitment/retention rates, data completion rates, intervention adherence rates, and participant intervention and trial participation satisfaction. Cost-utility and cost-effectiveness analyses will be undertaken. Outcome measures collected at baseline, 6 and 12 months will be used to evaluate the comparative clinical- and cost- effectiveness of customised versus prefabricated orthoses for this treatment of early rheumatoid arthritis foot conditions. This trial will help to guide orthotic prescription recommendations for the management of foot pain for people with early rheumatoid arthritis in future. ISRCTN13654421. Registered 09 February 2016.

  6. Investigating the Influence of Prefabricated Insole with Medial Flange on Forefoot and Rearfoot Alignment Changes at Females with Flexible Flat Foot

    Directory of Open Access Journals (Sweden)

    Fatemeh Dehghani

    2015-01-01

    Full Text Available Objective: Flexible flat foot is one the most common extremities diseases happen among adults, this causes change in foot, tibia, and higher joints alignment, pain and certain complications in upper joints and soft tissues. This study aimed to investigate differences in foot direction among patients with flexible flat feet as so called foot static response to a certain prefabricated insole. Materials & Methods: It was a quasi-experimental study and patients were consisted of 32 female with flat feet in range of 18 to 28 years old and to measure differences a laser device was used. The rear foot angle amount which is calculated by investigating the heel valgus angle and the forefoot angle amount which is calculated by investigating leg angle and forefoot, both assessed at barefoot condition and with medial flange insole mode. Results: Results showed that by using the insole there is a significant decrease in direction of anterior line angle (P<0.001. At mean, by using medial flange insole 3.5 degrees decrease at forefoot angle and 2.5 degrees decrease at heel angle was observed (P<0.001. Conclusion: This study showed that the prefabricated insole with high internal septum could normalize the direction of foot. Namely, it corrected the heel angle and leg deviations. Moreover, the NAS line despite of specifying the leg changes, it represents the influence of orthoses on this section.

  7. Rocker-sole footwear versus prefabricated foot orthoses for the treatment of pain associated with first metatarsophalangeal joint osteoarthritis: study protocol for a randomised trial

    Science.gov (United States)

    2014-01-01

    Background Osteoarthritis affecting the first metatarsophalangeal joint of the foot is a common condition which results in pain, stiffness and impaired ambulation. Footwear modifications and foot orthoses are widely used in clinical practice to treat this condition, but their effectiveness has not been rigorously evaluated. This article describes the design of a randomised trial comparing the effectiveness of rocker-sole footwear and individualised prefabricated foot orthoses in reducing pain associated with first metatarsophalangeal joint osteoarthritis. Methods Eighty people with first metatarsophalangeal joint osteoarthritis will be randomly allocated to receive either a pair of rocker-sole shoes (MBT® Matwa, Masai Barefoot Technology, Switzerland) or a pair of individualised, prefabricated foot orthoses (Vasyli Customs, Vasyli Medical™, Queensland, Australia). At baseline, the biomechanical effects of the interventions will be examined using a wireless wearable sensor motion analysis system (LEGSys™, BioSensics, Boston, MA, USA) and an in-shoe plantar pressure system (Pedar®, Novel GmbH, Munich, Germany). The primary outcome measure will be the pain subscale of the Foot Health Status Questionnaire (FHSQ), measured at baseline and 4, 8 and 12 weeks. Secondary outcome measures will include the function, footwear and general foot health subscales of the FHSQ, severity of pain and stiffness at the first metatarsophalangeal joint (measured using 100 mm visual analog scales), global change in symptoms (using a 15-point Likert scale), health status (using the Short-Form-12® Version 2.0 questionnaire), use of rescue medication and co-interventions to relieve pain, the frequency and type of self-reported adverse events and physical activity levels (using the Incidental and Planned Activity Questionnaire). Data will be analysed using the intention to treat principle. Discussion This study is the first randomised trial to compare the effectiveness of rocker

  8. Predictors of response to prefabricated foot orthoses or rocker-sole footwear in individuals with first metatarsophalangeal joint osteoarthritis

    OpenAIRE

    Menz, HB; Auhl, M; Tan, JM; Levinger, P; Roddy, E; Munteanu, SE

    2017-01-01

    BACKGROUND: Osteoarthritis of the first metatarsophalangeal joint (1st MTPJ OA) is a common and disabling condition commonly managed with footwear and orthotic interventions. The objective of this study was to identify factors associated with a successful treatment response in people with 1st MTPJ OA provided with prefabricated orthoses or rocker-sole footwear as part of a randomised clinical trial. METHODS: People with 1st MTPJ OA (n = 88) who participated in a randomised trial were allocate...

  9. Contours, 2 foot contours automatically generated from 2008 LIDAR for the purpose of supporting FEMA floodplain mapping. Limited manual editing, breaklines for waterbodies greater than 5 acres created and use.10' index contours labeled., Published in 2008, 1:1200 (1in=100ft) scale, City of Portage Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Contours dataset current as of 2008. 2 foot contours automatically generated from 2008 LIDAR for the purpose of supporting FEMA floodplain mapping. Limited manual...

  10. Fairfax County Contours

    Data.gov (United States)

    Federal Emergency Management Agency, Department of Homeland Security — This layer contains contours that were derived from the digital terrain model made up of irregularly spaced mass points and breaklines. The contours are 5 foot...

  11. High Resolution Elevation Contours

    Data.gov (United States)

    Minnesota Department of Natural Resources — This dataset contains contours generated from high resolution data sources such as LiDAR. Generally speaking this data is 2 foot or less contour interval.

  12. [Prefabrication of bone transplants].

    Science.gov (United States)

    Jagodzinski, M; Kokemüller, H; Jehn, P; Vogt, P; Gellrich, N-C; Krettek, C

    2015-03-01

    Prefabrication of bone transplants is a promising option for large defects of the long bones, especially if there is compromised vascularization of the defect. This is especially true for postinfection bone defects and other types of atrophic nonunion. The generation of a foreign body membrane (Masquelet's technique) has been investigated in order to ameliorate the response of the host tissue surrounding the defect. In an experimental animal study, a blood vessel within a bone construct could be used to generate customized, vascularized osteogenic constructs that can be used to treat large bone defects in the future.

  13. GEORGIAN PRODUCTION PREFABRICATED CERAMIC FIREPLACE

    International Nuclear Information System (INIS)

    Gaprindashvili, G.; Chemia, M.; Kartozia, L.

    2006-01-01

    General description and basic working principles of new construction prefabricated ceramic fireplace are given. The presented fireplace represents a unique synthesis of various fireplaces distributed in Georgian and some European countries; however, it is distinguished for its higher efficiency and other advantages. (author)

  14. Planning of installations in prefabricated buildings

    Directory of Open Access Journals (Sweden)

    Stanojević Ana D.

    2014-01-01

    Full Text Available Planning installations is becoming an increasing problem in construction, because the number of devices for technical supply is constantly increasing with continual progress in science and technology. Since the installations of the building can not be viewed unrelated of the construction, problem of its planning is more complicated in prefabricated buildings because the elements of construction are prefabricated. Planning was formerly performed by embedding the installation in prefabricated elements. This method had a lot of flaws, and modern approach tends setting installation out of prefabricated elements except when the traditional approach proves as economical. Although the hot water heating with radiators is the most practical way of heating in prefabricated buildings, the under floor heating systems have greater and greater use. Today, prefabricated sanitary cabins have a huge use and they are much more economical in comparison to special panels for bathrooms that were once create. Approaches in terms of planning electrical installation are different, but for conventional constructed buildings, as well as prefabricated buildings, the use of lightweight prefabricated walls with embedded installations, today is recommended, when the room is loaded with a large number of this installations and if it is possible.

  15. Effect of custom-made and prefabricated insoles on plantar loading parameters during running with and without fatigue.

    Science.gov (United States)

    Lucas-Cuevas, Angel Gabriel; Pérez-Soriano, Pedro; Llana-Belloch, Salvador; Macián-Romero, Cecili; Sánchez-Zuriaga, Daniel

    2014-01-01

    Controversy exists whether custom-made insoles are more effective in reducing plantar loading compared to prefabricated insoles. Forty recreational athletes ran using custom-made, prefabricated, and the original insoles of their running shoes, at rest and after a fatigue run. Contact time, stride rate, and plantar loading parameters were measured. Neither the insole conditions nor the fatigue state modified contact time and stride rate. Addressing prevention of running injuries, post-fatigue loading values are of great interest. Custom-made insoles reduced the post-fatigue loading under the hallux (92 vs. 130 kPa, P heel compared to the prefabricated insoles. Finally, fatigue state did not influence plantar loading regardless the insole condition. In long-distance races, even a slight reduction in plantar loading at each foot strike may suppose a significant decrease in the overall stress experienced by the foot, and therefore the use of insoles may be an important protective mechanism for plantar overloading.

  16. Prefabricated vertical drains, vol. I : engineering guidelines.

    Science.gov (United States)

    1986-09-01

    This volume presents procedures and guidelines applicable to the design and instal : tion of prefabricated vertical drains to accelerate consolidation of soils. The : contents represent the Consultant's interpretation of the state-of-the-art as of : ...

  17. Prefabricated neck expanded skin flap with the superficial temporal vessels for facial resurfacing.

    Science.gov (United States)

    Lazzeri, Davide; Su, Weijie; Qian, Yunliang; Messmer, Caroline; Agostini, Tommaso; Spinelli, Giuseppe; Marcus, Jeffrey R; Levin, L Scott; Zenn, Micheal R; Zhang, Yi Xin

    2013-05-01

    The achievement of a normal-appearing face after surgical resurfacing remains an elusive goal. This is due in part to insufficient color matching, restoration of contours, and the persistence of visible scars. Flap prefabrication is a staged procedure that provides an independent axial blood supply to local expanded tissues. We describe a new reconstructive alternative with superior reconstructive surgical options for facial resurfacing that better matches damaged or discarded facial tissues. A superficial temporal fascial flap was harvested as the vascular supply of the prefabricated neck flap and located in a subcutaneous neck pocket over a tissue expander. After a 5-month period for expansion and maturation, the prefabricated skin flap was raised, islanded, and rotated to resurface the facial defect. Four patients with hemifacial postburn contracture and two patients affected by hemifacial vascular malformations aged 17 to 42 years (mean 29 years) were successfully treated with no major complication after a mean period of 15 months. Prefabricated neck-expanded skin flap demonstrated an excellent color and texture match with facial skin that surrounded the repair sites, and optimal aesthetic results were obtained. Importantly, facial expression was completely maintained due to thinness and pliability of the rotated skin. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. The Prefabricated Interior Design Studio: An Exploration into the History and Sustainability of Interior Prefabrication

    Science.gov (United States)

    Schneiderman, Deborah; Freihoefer, Kara

    2013-01-01

    This article examines the integration of prefabrication into an interior design studio. A review of the literature revealed that while there is a paucity of categorical research focused on this subject, the subject is historically significant with an abundance of evidence regarding the prefabrication of the interior environment dating back…

  19. Fire resistance of prefabricated monolithic slab

    Directory of Open Access Journals (Sweden)

    Gravit Marina

    2017-01-01

    Full Text Available A prefabricated monolithic slab (PMS has a number of valuable advantages, they allow to significantly decrease the weight of construction keeping the necessary structural-load capacity, to speed up and cheapen work conduction, to increase the heat isolating properties of an enclosure structure [1]. In order to create a design method of prefabricated monolithic slab fire-resistance, it's necessary to perform a series of PMS testing, one of which is being described in this article. Subjected to the test is a fragment of prefabricated monolithic slab with polystyrene concrete inserts along the beams with bent metal profile 250 mm thick, with a 2.7 m span loaded with evenly spread load equal to 600 kg/m2. After 3 hour testing for fire-resistance [2] no signs of construction ultimate behavior were detected.

  20. Contours, 2ft Contour Information in AutoCAD & ArcInfo formats. AutoCAD contains cut line information. NAD83, Nevada State Plane, West Zone, US Foot. Broken into Township, Range, and Section Grids, Published in 2006, City of Carson City Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Contours dataset current as of 2006. 2ft Contour Information in AutoCAD & ArcInfo formats. AutoCAD contains cut line information. NAD83, Nevada State Plane, West...

  1. Clinical evaluation of prefabricated ceramic inlays

    Directory of Open Access Journals (Sweden)

    H Murali

    2016-01-01

    Full Text Available Background: One of the methods to overcome the problem of polymerization contraction of posterior composites is to use prefabricated ceramic inlays in combination with composites. Several studies have shown that these pre fabricated ceramic inlays act as mega fillers which allow a reduction in resin based composite volume by 50-75% and a concomitant reduction in polymerization shrinkage and marginal micro leakage. Moreover the integration of pre fabricated ceramic inlays into composites reduces the overall coefficient of thermal expansion. Aims and Objectives: The performance of cerena prefabricated inlay system was evaluated. Material and Methods: 20 proximo occlusal cavities were restored with cerana prefabricated inlay system in patients. The performance of cerena pre fabricated inlay system in the oral cavity was recorded at base line follow up using Modified USPHS Ryge criteria at the end of 3, 6, and 12 months. Results: The alpha and Bravo values for the anatomic form, marginal integrity and caries assessment was evaluated. Alpha values were ideal. The Cerena pre- fabricated inlay system showed good fracture resistance, good marginal integrity and maintenance of antomic forms at end of 12 months period. Conclusion: The cerena pre-fabricated inlay system is a good treatment modality and provides a good restorative material at the end of 12 months too.

  2. Nuclear power plant piping prefabrication and assembly

    International Nuclear Information System (INIS)

    Schmidt, H.

    1990-01-01

    The piping design for nuclear power plants projects reveals, at the beginning, a modification through the application of new fabrication techniques for prefabrication and assembly. This report presents a fabrication methodology which aims to minimize the fabrication and assembly costs as well as to improve and assure quality. (Author) [es

  3. Prefabrication in Building Construction: A Perspective of Pakistan Construction Industry

    Directory of Open Access Journals (Sweden)

    Nafees Ahmed Memon

    2014-07-01

    Full Text Available Construction industry is facing many problems in terms of construction waste, quality, environment, durability, safety and higher construction cost. Adoption of prefabrication is a possible solution to such problems. Accordingly, there is a need to study the prospects that would stimulate the appropriate discussion of the suitability of prefabrication and other construction methods for concrete buildings. Therefore, this study investigates the significance of advantages in adopting prefabrication along with hindrances through questionnaire survey. The data has been analyzed using RIW (Relative Importance Weight method as a MCDM approach. The results depict that main advantages of prefabrication are ?Shorter construction time? and ?Less construction site waste?. The top hindrances in adopting prefabrication as identified in this study are: ?Higher initial construction cost? and ?Inflexible for design changes?. Based on the survey results and apparent progress in the adoption of prefabrication around the world, it is concluded that the use of prefabrication is likely to increase in developing countries like Pakistan

  4. Prefabrication in building construction: a perspective of pakistan construction industry

    International Nuclear Information System (INIS)

    Memon, N.A.; Memon, F.A.; Khehro, S.H.

    2014-01-01

    Construction industry is facing many problems in terms of construction waste, quality, environment, durability, safety and higher construction cost. Adoption of prefabrication is a possible solution to such problems. Accordingly, there is a need to study the prospects that would stimulate the appropriate discussion of the suitability of prefabrication and other construction methods for concrete buildings. Therefore, this study investigates the significance of advantages in adopting prefabrication along with hindrances through questionnaire survey. The data has been analyzed using RIW (Relative Importance Weight) method as a MCDM approach. The results depict that main advantages of prefabrication are Shorter construction time and Less construction site waste. The top hindrances in adopting prefabrication as identified in this study are: Higher initial construction cost and Inflexible for design changes. Based on the survey results and apparent progress in the adoption of prefabrication around the world, it is concluded that the use of prefabrication is likely to increase in developing countries like Pakistan. (author)

  5. The pre-fabrication of building facades

    CERN Document Server

    Rangel, Bárbara; Faria, José

    2017-01-01

    This book compares two buildings with different technologies and distinct environment from the combined viewpoints of civil engineering and architecture. The first is the most recent building of Columbia University in New York, the Northwest Science Building, a project designed by Rafael Moneo and Dan Brodkin of Ove Arup. The second one is the Burgo Tower in Oporto, by Eduardo Souto Moura and Rui Furtado of AFA, a building that brings a new perspective to the use of prefabrication technologies with local traditional construction systems. With the detailed analyses of recognized researchers in civil engineering and architecture, this book is a reflection upon the problems and solutions in the design and construction process of a prefabricated building system. This volume, like those to follow, brings together, building research and building design practice to enhance the knowledge of complementarity areas involved in construction, engineering and architecture. This is the first book in a new series "Building R...

  6. Face resurfacing using a cervicothoracic skin flap prefabricated by lateral thigh fascial flap and tissue expander.

    Science.gov (United States)

    Li, Qingfeng; Zan, Tao; Gu, Bin; Liu, Kai; Shen, Guoxiong; Xie, Yun; Weng, Rui

    2009-01-01

    Resurfacing of facial massive soft tissue defect is a formidable challenge because of the unique character of the region and the limitation of well-matched donor site. In this report, we introduce a technique for using the prefabricated cervicothoracic skin flap for facial resurfacing, in an attempt to meet the principle of flap selection in face reconstructive surgery for matching the color and texture, large dimension, and thinner thickness (MLT) of the recipient. Eleven patients with massive facial scars underwent resurfacing procedures with prefabricated cervicothoracic flaps. The vasculature of the lateral thigh fascial flap, including the descending branch of the lateral femoral circumflex vessels and the surrounding muscle fascia, was used as the vascular carrier, and the pedicles of the fascial flap were anastomosed to either the superior thyroid or facial vessels in flap prefabrication. A tissue expander was placed beneath the fascial flap to enlarge the size and reduce the thickness of the flap. The average size of the harvested fascia flap was 6.5 x 11.7 cm. After a mean interval of 21.5 weeks, the expanders were filled to a mean volume of 1,685 ml. The sizes of the prefabricated skin flaps ranged from 12 x 15 cm to 15 x 32 cm. The prefabricated skin flaps were then transferred to the recipient site as pedicled flaps for facial resurfacing. All facial soft tissue defects were successfully covered by the flaps. The donor sites were primarily closed and healed without complications. Although varied degrees of venous congestion were developed after flap transfers, the marginal necrosis only occurred in two cases. The results in follow-up showed most resurfaced faces restored natural contour and regained emotional expression. MLT is the principle for flap selection in resurfacing of the massive facial soft tissue defect. Our experience in this series of patients demonstrated that the prefabricated cervicothoracic skin flap could be a reliable alternative

  7. Prefabricated house in real estate business development in Jabodetabek

    Science.gov (United States)

    Gumilang Raksamala Basmara Putra, Raka; Susanto, Dalhar

    2017-12-01

    Within constructional technology prefabricated house is known as a house whose most of the components like walls, roofs, toilets, and structural cubes and columns are designated and produced in factory and assembled in site. Based on the experience in certain countries, prefabricated house has successfully entered commercial market. Prefabricated house shows a better infestation value than conventional houses. With prefabrication technology, building construction could be done faster and cost lower price, along with a good craftsmanship quality. Until now, Indonesia is still facing settlements issues and one of them is housing backlog whose amount revolves around 13 Million units. Prefabricated houses potentially solve the settlement issue in Indonesia in a much faster way. Yet the development of prefabricated house has not been accepted well in the market yet, both by the producers and the consumers. This writing talks about the result of the research about the causes of the lack of development in Indonesia when it comes to prefabricated houses though the method of comparison; comparing prefabricated house with conventional house when it comes to its 1) productivity rate, 2) consumers preference and 3) infestation performance. The data is collected through survey methods, interview and questionnaires. The result shows that even though the productivity rate when it comes to quality and time is high, prefabricated house shows low productivity when it comes to cost because it requires greater cost than it is in conventional houses. Other than that, the lack of business development when it comes to prefabricated houses is caused by the low preference of consumers toward the product- because of its inflexibility and monotonous appearance. The infestation of prefabricated house development shows a low NPV and IRR. With a more proper infestation approach such as mass constructions with effective numbers, good flexibility, and various appearances, prefabricated house

  8. Research Status on Bonding Behavior of Prefabricated Concrete Shear Wall

    Science.gov (United States)

    Wang, Donghui; Liu, Xudong; Wang, Sheng; Li, Shanshan

    2018-03-01

    Prefabricated shear wall structure adapts to the development and requirements of China’s residential industrialization. The key to the prefabricated concrete shear wall structure is the connection between the prefabricated members, where the reliability of the connection of the concrete joint is related to the overall performance and seismic effect of the structure. In this paper, the microstructures of the joint surface and shear properties are analysed, and the formula for calculating the shear strength of the joint is obtained.

  9. Exploring the beliefs of Australian prefabricated house builders

    Directory of Open Access Journals (Sweden)

    Dale A Steinhardt

    2016-06-01

    Full Text Available The housing sector accounts for a majority of newly constructed buildings. Prefabrication, defined as the factory construction of houses or significant components, is widely promoted as a means to improve efficiency. This paper focuses on the research questions: RQ1. What are the attitudes of builders towards prefabrication adoption? RQ2. What types of stakeholders do builders believe influence their adoption decisions? RQ3. What types of contextual influences do builders believe impact their adoption decisions? Current prefabrication research has focused on the advantages and disadvantages of prefabrication, without further unpacking the beliefs of stakeholders that underpin them. This paper addresses this gap and increases the understanding of beliefs that can frame interventions to increase the market penetration of prefabrication. Fourteen interviews with Australian prefabricators were undertaken as a Belief Elicitation Study. This qualitative methodology is framed by the Theory of Planned Behaviour (TPB and the Technology Acceptance Model (TAM. Results show that modern high-quality prefabricated housing has struggled to overcome historical stigma; improved construction speed has not and is not likely to translate to reduced totals costs for a majority of firms; and prefabrication adoption has been hindered by an almost completely unsupportive industry infrastructure. Recommendations are made to frame arguments in improving short-term outcomes for an industry driven by practical considerations. Future discourse must focus on cost impacts, financial security and risk reduction. Establishing networks of prefabricators that can build a strong, unified voice for the industry should be prioritised.

  10. Ocean Sediment Thickness Contours

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ocean sediment thickness contours in 200 meter intervals for water depths ranging from 0 - 18,000 meters. These contours were derived from a global sediment...

  11. Tagged Vector Contour (TVC)

    Data.gov (United States)

    Kansas Data Access and Support Center — The Kansas Tagged Vector Contour (TVC) dataset consists of digitized contours from the 7.5 minute topographic quadrangle maps. Coverage for the state is incomplete....

  12. Studies of the Prefabricated Housing Construction Market in Poland

    Science.gov (United States)

    Radziszewska-Zielina, Elżbieta; Gleń, Monika

    2014-11-01

    The directions of development of the construction market are not only related to the need to own one's own home but also to increasing functional and economic requirements and conditions of sustainable development. The perception and understanding of prefabrication in housing construction are undoubtedly starting to change. Sustainable construction criteria may constitute a significant turning point and support for the development of new prefabricated housing construction technologies. Entrepreneurs are slowly perceiving an opportunity for the development of prefabrication in the construction market. The implementation and popularisation of ready-made homes will undoubtedly constitute a favourable change in the Polish construction market; however, this will require a modification of habits. This article presents an historical analysis of the development of the prefabricated housing construction market as well as an attempt to answer questions concerning the future of prefabrication in housing construction in Poland based on the conducted studies.

  13. The immediate effects of foot orthoses on functional performance in individuals with patellofemoral pain syndrome.

    Science.gov (United States)

    Barton, C J; Menz, H B; Crossley, K M

    2011-03-01

    Patellofemoral pain syndrome (PFPS) often results in reduced functional performance. There is growing evidence for the use of foot orthoses to treat this multifactorial condition. In this study, the immediate effects of foot orthoses on functional performance and the association of foot posture and footwear with improvements in function were evaluated. Fifty-two individuals with PFPS (18-35 years) were prescribed prefabricated foot orthoses (Vasyli Pro; Vasyli International, Labrador, Australia). Functional outcome measures evaluated included the change in (1) pain and (2) ease of a single-leg squat on a five-point Likert scale, and change in the number of (3) pain-free step downs and (4) single-leg rises from sitting. The association of foot posture using the Foot Posture Index, navicular drop and calcaneal angle relative to subtalar joint neutral; and the footwear motion control properties scale score with improved function were evaluated using Spearman's ρ statistics. Prefabricated foot orthoses produced significant improvements (psquat and improvements in the number of pain-free single-leg rises from sitting when wearing foot orthoses. In addition, a more pronated foot type was also found to be associated with improved ease of completing a single-leg squat when wearing foot orthoses. Prefabricated foot orthoses provide immediate improvements in functional performance, and these improvements are associated with a more pronated foot type and poorer footwear motion control properties.

  14. Prefabricated Construction using Digitally Integrated Industrial Manufacturing

    Directory of Open Access Journals (Sweden)

    Harry Giles

    2012-10-01

    Full Text Available The paper describes research being carried out in relation to prefabricated high density affordablehousing under a grant from the Partnership for the Advancement of Technology in Housing(PATH and the National Science Foundation (NSF in the USA. The objective is to demonstratehow a new paradigm for the conceptualization and construction of buildings can be conceivedof as an entirely factory based process that creates advantages for construction through industrialsystems technology transfer. Our approach is intended to transform design methodologythrough demonstrating how alternative construction concepts, using entirely pre-manufacturedvolumetric units, can be adopted. This involves digital modeling that facilitates parametric variationsfor creating customized prefabricated products from design conceptualization through tofinal product delivery. The paper discusses key areas under investigation in relation to a manufacturingparadigm used in the automotive industry that integrates virtual prototyping and industrialmanufacturing systems. Our research explores a type of monocoque volumetric unit prefabricatedin steel, which will be pre-finished as part of a modular factory-built approach usingindustrialized methodologies that will facilitate customized manufacture of a high quality energyefficient product for affordable housing.The paper addresses the automotive industry methods of manufacture that have served increasedautomobile performance and economics through mass production for over a century. In starkcontrast, the building industry and in particular the housing industry is still a century behind. It issuggested that a move away from tradition will require an industry wide initiative, just like HenryFord led the way with mass production. By embracing the increasing sophistication and capabilitythat digital technology offers, it is shown how digital tools are implemented towards masscustomization in house design using virtual modeling in the

  15. Indoor Noise Loading in Residential Prefabricated Buildings

    Science.gov (United States)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.

  16. En bloc prefabrication of vascularized bioartificial bone grafts in sheep and complete workflow for custom-made transplants.

    Science.gov (United States)

    Kokemüller, H; Jehn, P; Spalthoff, S; Essig, H; Tavassol, F; Schumann, P; Andreae, A; Nolte, I; Jagodzinski, M; Gellrich, N-C

    2014-02-01

    The aim of this pilot study was to determine, in a new experimental model, whether complex bioartificial monoblocs of relevant size and stability can be prefabricated in a defined three-dimensional design, in which the latissimus dorsi muscle serves as a natural bioreactor and the thoracodorsal vessel tree is prepared for axial construct perfusion. Eighteen sheep were included in the study, with six animals in each of three experimental groups. Vitalization of the β-tricalcium phosphate-based constructs was performed by direct application of unmodified osteogenic material from the iliac crest (group A), in vivo application of nucleated cell concentrate (NCC) from bone marrow aspirate (group B), and in vitro cultivation of bone marrow stromal cells (BMSC) in a perfusion bioreactor system (group C). The contours of the constructs were designed digitally and transferred onto the bioartificial bone grafts using a titanium cage, which was bent over a stereolithographic model of the defined subvolume intraoperatively. At the end of the prefabrication process, only the axial vascularized constructs of group A demonstrated vital bone formation with considerable stability. In groups B and C, the applied techniques were not able to induce ectopic bone formation. The presented computer-assisted workflow allows the prefabrication of custom-made bioartificial transplants. Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Prefabricated Engineered Bamboo Housing for East Africa | CRDI ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    This project will endeavor to transfer new bamboo-based prefabricated housing technology from China and India to ... durable, healthy and environmentally friendly houses for the urban poor. ... International Network for Bamboo and Rattan.

  18. (Con)fusing contours

    NARCIS (Netherlands)

    Lier, R.J. van; Wit, T.C.J. de; Koning, A.R.

    2005-01-01

    We have created patterns in which illusory Kanizsa squares are positioned on top of a background grid of bars. When the illusory contours and physical contours are misaligned, the resulting percept appears to be rather confusing (van Lier et al, 2004 Perception 33 Supplement, 77). Observers often

  19. Male Body Contouring.

    Science.gov (United States)

    Singh, Babu; Keaney, Terrence; Rossi, Anthony M

    2015-09-01

    Men are increasingly turning to dermatologists and plastic surgeons to request procedures that correct or enhance physical features. With the advent of this emerging new patient population, alterations in preexisting aesthetic techniques, gender-specific uses of existing devices and overall approaches need to be revisited and adapted to obtain results that are suitable for the male patient. Recently, body contouring has become one of the most sought out procedures by men. Although the majority of clinical studies involving body contouring esthetics are performed with female patients, gains from such studies can be extrapolated to men. Body contouring can be broadly classified as non-invasive or invasive, depending on the modality used. Non-invasive contouring is most frequently performed with devices that target subcutaneous adipose with focused electrical or thermal energy, including low-level laser, cryolipolysis, ultrasonography, and radiofrequency. Invasive body contouring modalities useful for male body contouring include liposuction, pectoral and abdominal wall etching, jawline fillers, synthetic deoxycholic acid injections, and solid silicone implants. The purpose of this review is to bring attention to the unique aspects, strategies, and modalities used in aesthetic body contouring for the male patient.

  20. CONTOUR investigation launched

    Science.gov (United States)

    Showstack, Randy

    On 27 August, NASA Administrator Sean O'Keefe appointed a team to investigate the apparent loss of the Comet Nucleus Tour (CONTOUR) spacecraft, which stopped communicating with the mission control operations on 15 August.On that date, CONTOUR failed to communicate following the firing of its main engine that would take it out of its orbit around the Earth. Shortly afterwards, the mission team received telescope images from several observatories showing two objects traveling along the spacecraft's predicted path. Those objects could be CONTOUR, and part of the spacecraft that may have separated from it when the spacecraft's solid rocket motor fired.

  1. Spectrally accurate contour dynamics

    International Nuclear Information System (INIS)

    Van Buskirk, R.D.; Marcus, P.S.

    1994-01-01

    We present an exponentially accurate boundary integral method for calculation the equilibria and dynamics of piece-wise constant distributions of potential vorticity. The method represents contours of potential vorticity as a spectral sum and solves the Biot-Savart equation for the velocity by spectrally evaluating a desingularized contour integral. We use the technique in both an initial-value code and a newton continuation method. Our methods are tested by comparing the numerical solutions with known analytic results, and it is shown that for the same amount of computational work our spectral methods are more accurate than other contour dynamics methods currently in use

  2. Capital Cost Optimization for Prefabrication: A Factor Analysis Evaluation Model

    Directory of Open Access Journals (Sweden)

    Hong Xue

    2018-01-01

    Full Text Available High capital cost is a significant hindrance to the promotion of prefabrication. In order to optimize cost management and reduce capital cost, this study aims to explore the latent factors and factor analysis evaluation model. Semi-structured interviews were conducted to explore potential variables and then questionnaire survey was employed to collect professionals’ views on their effects. After data collection, exploratory factor analysis was adopted to explore the latent factors. Seven latent factors were identified, including “Management Index”, “Construction Dissipation Index”, “Productivity Index”, “Design Efficiency Index”, “Transport Dissipation Index”, “Material increment Index” and “Depreciation amortization Index”. With these latent factors, a factor analysis evaluation model (FAEM, divided into factor analysis model (FAM and comprehensive evaluation model (CEM, was established. The FAM was used to explore the effect of observed variables on the high capital cost of prefabrication, while the CEM was used to evaluate comprehensive cost management level on prefabrication projects. Case studies were conducted to verify the models. The results revealed that collaborative management had a positive effect on capital cost of prefabrication. Material increment costs and labor costs had significant impacts on production cost. This study demonstrated the potential of on-site management and standardization design to reduce capital cost. Hence, collaborative management is necessary for cost management of prefabrication. Innovation and detailed design were needed to improve cost performance. The new form of precast component factories can be explored to reduce transportation cost. Meanwhile, targeted strategies can be adopted for different prefabrication projects. The findings optimized the capital cost and improved the cost performance through providing an evaluation and optimization model, which helps managers to

  3. Prefabricated fibula free flap with dental implants for mandibular reconstruction.

    Science.gov (United States)

    Pauchet, D; Pigot, J-L; Chabolle, F; Bach, C-A

    2018-03-02

    Free fibula transplant is routinely used for mandibular reconstruction in head and neck cancer. Dental rehabilitation, the objective of mandibular reconstruction, requires the use of dental implants as supports for fixed or removable dentures. Positioning of fibular bone grafts and implants determines implant osseointegration and the possibilities of dental rehabilitation. Prefabrication of a fibula free flap with dental implants prior to harvesting as a free flap can promote implant osseointegration. The position of the implants must then be precisely planned. Virtual surgery and computer-assisted design and prefabrication techniques are used to plan the reconstruction and then reproduce this planning by means of tailored fibula and mandible cutting guides, thereby ensuring correct positioning of fibular bone fragments and implants. The prefabricated fibula free flap technique requires two surgical procedures (prefabrication and flap transfer) and precise preoperative planning. Prefabricated fibula free flap with dental implants, by improving the quality of osseointegration of the implants before flap transfer, extends the possibilities of prosthetic rehabilitation in complex secondary mandibular reconstructions. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  4. Effectiveness of Foot Orthoses Versus Rocker-Sole Footwear for First Metatarsophalangeal Joint Osteoarthritis: Randomized Trial.

    Science.gov (United States)

    Menz, Hylton B; Auhl, Maria; Tan, Jade M; Levinger, Pazit; Roddy, Edward; Munteanu, Shannon E

    2016-05-01

    To compare the effectiveness of prefabricated foot orthoses to rocker-sole footwear in reducing foot pain in people with first metatarsophalangeal (MTP) joint osteoarthritis (OA). Participants (n = 102) with first MTP joint OA were randomly allocated to receive individualized, prefabricated foot orthoses or rocker-sole footwear. The primary outcome measure was the pain subscale on the Foot Health Status Questionnaire (FHSQ) at 12 weeks. Secondary outcome measures included the function, footwear, and general foot health subscales of the FHSQ; the Foot Function Index; severity of pain and stiffness at the first MTP joint; perception of global improvement; general health status; use of rescue medication and co-interventions to relieve pain; physical activity; and the frequency of self-reported adverse events. The FHSQ pain subscale scores improved in both groups, but no statistically significant difference between the groups was observed (adjusted mean difference 2.05 points, 95% confidence interval [95% CI] -3.61, 7.71; P = 0.477). However, the footwear group exhibited lower adherence (mean ± SD total hours worn 287 ± 193 versus 448 ± 234; P footwear are similarly effective at reducing foot pain in people with first MTP joint OA. However, prefabricated foot orthoses may be the intervention of choice due to greater adherence and fewer associated adverse events. © 2016 The Authors. Arthritis Care & Research published by Wiley Periodicals, Inc. on behalf of the American College of Rheumatology.

  5. Safety concerns related to modular/prefabricated building construction.

    Science.gov (United States)

    Fard, Maryam Mirhadi; Terouhid, Seyyed Amin; Kibert, Charles J; Hakim, Hamed

    2017-03-01

    The US construction industry annually experiences a relatively high rate of fatalities and injuries; therefore, improving safety practices should be considered a top priority for this industry. Modular/prefabricated building construction is a construction strategy that involves manufacturing of the whole building or some of its components off-site. This research focuses on the safety performance of the modular/prefabricated building construction sector during both manufacturing and on-site processes. This safety evaluation can serve as the starting point for improving the safety performance of this sector. Research was conducted based on Occupational Safety and Health Administration investigated accidents. The study found 125 accidents related to modular/prefabricated building construction. The details of each accident were closely examined to identify the types of injury and underlying causes. Out of 125 accidents, there were 48 fatalities (38.4%), 63 hospitalized injuries (50.4%), and 14 non-hospitalized injuries (11.2%). It was found that, the most common type of injury in modular/prefabricated construction was 'fracture', and the most common cause of accidents was 'fall'. The most frequent cause of cause (underlying and root cause) was 'unstable structure'. In this research, the accidents were also examined in terms of corresponding location, occupation, equipment as well as activities during which the accidents occurred. For improving safety records of the modular/prefabricated construction sector, this study recommends that future research be conducted on stabilizing structures during their lifting, storing, and permanent installation, securing fall protection systems during on-site assembly of components while working from heights, and developing training programmes and standards focused on modular/prefabricated construction.

  6. Desferrioxamine: a practical method for improving neovascularization of prefabricated flaps.

    Science.gov (United States)

    Li, Bin; Li, Hua; Jin, Rui; Cheng, Chen; Wang, Jing; Zhu, Hainan; Zan, Tao; Li, Qingfeng; Hao, Lijun

    2015-02-01

    Prefabricated flaps are an ideal alternative to repair massive and complex tissue defects. Nevertheless, the risk of necrosis due to unpredictable blood supplies is a major obstacle to the application of prefabricated flaps. The survival of a prefabricated flap depends on the neovascularization between the vascular carrier and the donor tissue. Here, we proposed that the iron chelator, desferrioxamine (DFX), owned therapeutic effects that promoted the neovascularization of prefabricated flaps. An abdominal prefabricated flap model was created in rats via a 2-stage operation. The rats were allocated into 4 groups as follows: 2 groups of rats received DFX treatments during the first or the second stage of the operation, respectively; 1 group of rats received a delay procedure 1 week before the second operation; and the final group was used as a blank control. Flap survival rates and capillary densities were evaluated between groups. The influence of DFX on the dermal fibroblasts was also studied in vitro. Desferrioxamine treatment during the first stage of the operation greatly increased flap survival rate compared to the blank control. The results were similar to those produced by the delay treatment. The vessel count results were consistent with the flap survival rate findings. In vitro, DFX treatment up-regulated the expression levels of several angiogenic factors in the dermal fibroblasts. Nevertheless, DFX treatment during the second stage of the operation was therapeutically detrimental. The application of DFX around the time of vascular carrier implantation greatly promoted neovascularization of prefabricated flaps, but was therapeutically detrimental after the flaps had been elevated.

  7. Heat transfer unit and method for prefabricated vessel

    Science.gov (United States)

    Tamburello, David A.; Kesterson, Matthew R; Hardy, Bruce J.

    2017-11-07

    Vessel assemblies, heat transfer units for prefabricated vessels, and methods for heat transfer prefabricated vessel are provided. A heat transfer unit includes a central rod, and a plurality of peripheral rods surrounding the central rod and connected to the central rod. The plurality of peripheral rods are movable between a first collapsed position and a second bowed position, wherein in the second bowed position a midpoint of each of the plurality of peripheral rods is spaced from the central rod relative to in the first position. The heat transfer unit further includes a heat transfer element connected to one of the plurality of peripheral rods.

  8. Prefabricated elements and structures: Developments, tests and experiences

    DEFF Research Database (Denmark)

    Goltermann, Per

    2014-01-01

    Danish concrete structures are often built with prefabricated elements, joined together on the site and this provides a large challenge to constantly improve and optimize the elements, the joints and the models. DTU Byg has been active in the development, testing and modelling of new elements...

  9. Improving the Learning Process in the Latest Prefabricated School Buildings

    Science.gov (United States)

    Pons, Oriol; Oliva, Josep-Manuel; Maas, Sandra-Ruth

    2010-01-01

    Since 2000 hundreds of school centers have been constructed in Catalonia using industrialized technologies. These centers are modern, useful, educational edifices built using advantageous prefabricated technologies that improve the building process and reduce the environmental impact of the building. This article analyses whether these…

  10. Holographic Moire Contouring

    Science.gov (United States)

    Sciammarella, C. A.; Sainov, Ventseslav; Simova, Eli

    1990-04-01

    Theoretical analysis and experimental results on holographic moire contouring (HMC) of difussely reflecting objects are presented. The sensitivity and application constraints of the method are discussed. A high signal-to-noise ratio and contrast of the fringes is achieved through the use of high quality silver halide holographic plates HP-650. A good agreement between theoretical and experimental results is observed.

  11. Foot Health

    Science.gov (United States)

    ... straight across and not too short Your foot health can be a clue to your overall health. For example, joint stiffness could mean arthritis. Tingling ... foot checks are an important part of your health care. If you have foot problems, be sure ...

  12. The Development of Contour Interpolation: Evidence from Subjective Contours

    Science.gov (United States)

    Hadad, Bat-Sheva; Maurer, Daphne; Lewis, Terri L.

    2010-01-01

    Adults are skilled at perceiving subjective contours in regions without any local image information (e.g., [Ginsburg, 1975] and [Kanizsa, 1976]). Here we examined the development of this skill and the effect thereon of the support ratio (i.e., the ratio of the physically specified contours to the total contour length). Children (6-, 9-, and…

  13. Visualization of Uncertain Contour Trees

    DEFF Research Database (Denmark)

    Kraus, Martin

    2010-01-01

    Contour trees can represent the topology of large volume data sets in a relatively compact, discrete data structure. However, the resulting trees often contain many thousands of nodes; thus, many graph drawing techniques fail to produce satisfactory results. Therefore, several visualization methods...... were proposed recently for the visualization of contour trees. Unfortunately, none of these techniques is able to handle uncertain contour trees although any uncertainty of the volume data inevitably results in partially uncertain contour trees. In this work, we visualize uncertain contour trees...... by combining the contour trees of two morphologically filtered versions of a volume data set, which represent the range of uncertainty. These two contour trees are combined and visualized within a single image such that a range of potential contour trees is represented by the resulting visualization. Thus...

  14. New Transition Wedge Design Composed by Prefabricated Reinforced Concrete Slabs

    OpenAIRE

    Real-Herráiz, Julia; Zamorano-Martín, Clara; Real-Herráiz, Teresa; Morales-Ivorra, Silvia

    2016-01-01

    [EN] Important track degradation occurs in structure-embankment transitions, in which an abrupt change in track vertical stiffness arises, leading to a reduction in passengers comfort and safety. Although granular wedges are suggested by different railroad administrations as a solution to avoid these problems, they present some disadvantages which may affect track long-term performance. In this paper, a new solution designed with prefabricated reinforced concrete slabs is proposed. The aim of...

  15. Investigation on Prefabricated Building System Skilled Component Installers

    OpenAIRE

    Nurul Rezuana Buyung; Md Azree Othuman Mydin; Abdul Naser Abdul Ghani

    2013-01-01

    In the face of an increasingly challenging era of globalization, skills and new equipments which includes prefabricated building components, known as Industrialized Building System (IBS) has been introduced towards achievement of sustainable construction. IBS is a construction system in which the components are manufactured in a factory, on or off site, positioned and assembled into complete structures with minimal additional site work. IBS requires high construction precisi...

  16. Attempt of application of prefabrication techniques to nuclear engineering

    International Nuclear Information System (INIS)

    Frangi, Roger

    1981-01-01

    Prefabrication can apply to nuclear civil engineering for the execution of complicated or tall shuttering or casing work, requiring shoring that one would wish to simplify or suppress. This technique saves on work hours and improves quality and safety. A few examples carried out on the Saint-Laurent-des-Eaux and Chinon power stations are given as well as that which will be undertaken on the Belleville power station [fr

  17. Consolidation by Prefabricated Vertical Drains with a Threshold Gradient

    OpenAIRE

    Xiao Guo; Kang-He Xie; Yue-Bao Deng

    2014-01-01

    This paper shows the development of an approximate analytical solution of radial consolidation by prefabricated vertical drains with a threshold gradient. To understand the effect of the threshold gradient on consolidation, a parametric analysis was performed using the present solution. The applicability of the present solution was demonstrated in two cases, wherein the comparisons with Hansbo’s results and observed data were conducted. It was found that (1) the flow with the threshold gradie...

  18. Critical Points of Prefabricated Reinforced Concrete Wall Systems of Multi-storey Buildings

    OpenAIRE

    J. Witzany; T. Čejka; R. Zigler

    2011-01-01

    With respect to the dissipation of energy through plastic deformation of joints of prefabricated wall units, the paper points out the principal importance of efficient reinforcement of the prefabricated system at its joints. The method, quality and amount of reinforcement are essential for reaching the necessary degree of joint ductility. The paper presents partial results of experimental research of vertical joints of prefabricated units exposed to monotonously rising lo...

  19. Charcot Foot

    Science.gov (United States)

    ... damage (neuropathy). The bones are weakened enough to fracture, and with continued walking, the foot eventually changes ... difference. Advanced therapies for foot wounds are saving limbs, restoring ... in the feet come from the lower back. Pressure or chemical change in the nerve ...

  20. Detection of elliptical contours

    International Nuclear Information System (INIS)

    Blokland, J.A.K.

    1987-01-01

    This dissertation describes the quantitation of myocardial perfusion defects in planar thallium-201 scintigrams. To be able to quantify the distribution of 201 Tl in the myocardium as imaged by the scintigram, accurate delineation of the target object is a prerequisite. The distribution of the radionuclide within the contour of the left ventricle can be described by application of circumferential profiles. By comparing the computed circumferential profile with those of normal subjects, humans with no evidence of coronary artery disease, segments of the left ventricle with decreased bloodflow can be detected. In practice there is no real standard to compare with, and due to noise and biological variations, it is not always possible to make a definite decision regarding the presence of a defect in the distribution of the radionuclide. The value and limitations of the developed quantification procedure are discussed. Some future developments are suggested. 108 refs.; 57 figs.; 5 tabs

  1. Application of Prefabricated Vertical Drain in Soil Improvement

    Directory of Open Access Journals (Sweden)

    Tedjakusuma B.

    2012-01-01

    Full Text Available Although the use of Prefabricated Vertical Drain (PVD in soil improvement is not new, this paper is interesting since it gives the full spectrum from preliminary design stage; trial embankment and pilot test to final soil improvement. The final installation of the PVD was based on the soil investigation report and the results of instrumentation monitoring. Finally, using back analysis, vertical and horizontal coefficients of consolidation and compression index can be determined, which can be applied to predict a more accurate prediction of settlement.

  2. Accuracy of secondary maxillofacial reconstruction with prefabricated fibula grafts using 3D planning and guided reconstruction

    NARCIS (Netherlands)

    Schepers, Rutger H.; Kraeima, Joep; Vissink, Arjan; Lahoda, Lars U.; Roodenburg, Jan L. N.; Reintsema, Harry; Raghoebar, Gerry M.; Witjes, Max J.

    Background: We compared the pre-operative 3D-surgical plan with the surgical outcome of complex two-stage secondary reconstruction of maxillofacial defects using inserted implants in the prefabricated fibula graft. Methods: Eleven reconstructions of maxillofacial defects with prefabricated fibulas

  3. A Market Equilibrium Supply Chain Model for Supporting Self-Manufacturing or Outsourcing Decisions in Prefabricated Construction

    OpenAIRE

    Yanhu Han; Miroslaw J. Skibniewski; Lufan Wang

    2017-01-01

    Prefabricated construction is a sustainable alternative to traditional on-site construction methods. However, many challenges still exist in the prefabricated construction process. For example, self-manufacturing or outsourcing decisions are vital to the industrial structure and organization of the prefabricated construction industry, and the company’s production and operation decision-making. This paper considers a prefabricated construction supply chain, which is composed of one upstream co...

  4. Contours - MO 2012 Greene County 5ft Contours (SHP)

    Data.gov (United States)

    NSGIC State | GIS Inventory — 5ft cartographic contour file for Greene County, Missouri. This file was created using the elevation data from the 2011 LiDAR flight. It includes indexes for 10, 25,...

  5. Digital extraction of interference fringe contours

    International Nuclear Information System (INIS)

    Mastin, G.A.; Ghiglia, D.C.

    1985-01-01

    Two basic techniques for extracting interferogram contours have been discussed. The first is a global contour extracton technique based on the fast Fourier transform. The second extracts individual contours with a thinning algorithm using logical neighborhood transformations

  6. Computer assisted holographic moire contouring

    Science.gov (United States)

    Sciammarella, Cesar A.

    2000-01-01

    Theoretical analyses and experimental results on holographic moire contouring on diffusely reflecting objects are presented. The sensitivity and limitations of the method are discussed. Particular emphasis is put on computer-assisted data retrieval, processing, and recording.

  7. Visualizing Contour Trees within Histograms

    DEFF Research Database (Denmark)

    Kraus, Martin

    2010-01-01

    Many of the topological features of the isosurfaces of a scalar volume field can be compactly represented by its contour tree. Unfortunately, the contour trees of most real-world volume data sets are too complex to be visualized by dot-and-line diagrams. Therefore, we propose a new visualization...... that is suitable for large contour trees and efficiently conveys the topological structure of the most important isosurface components. This visualization is integrated into a histogram of the volume data; thus, it offers strictly more information than a traditional histogram. We present algorithms...... to automatically compute the graph layout and to calculate appropriate approximations of the contour tree and the surface area of the relevant isosurface components. The benefits of this new visualization are demonstrated with the help of several publicly available volume data sets....

  8. Image Interpolation with Contour Stencils

    OpenAIRE

    Pascal Getreuer

    2011-01-01

    Image interpolation is the problem of increasing the resolution of an image. Linear methods must compromise between artifacts like jagged edges, blurring, and overshoot (halo) artifacts. More recent works consider nonlinear methods to improve interpolation of edges and textures. In this paper we apply contour stencils for estimating the image contours based on total variation along curves and then use this estimation to construct a fast edge-adaptive interpolation.

  9. New Transition Wedge Design Composed by Prefabricated Reinforced Concrete Slabs

    Directory of Open Access Journals (Sweden)

    Julia Real-Herráiz

    Full Text Available Abstract Important track degradation occurs in structure-embankment transitions, in which an abrupt change in track vertical stiffness arises, leading to a reduction in passengers comfort and safety. Although granular wedges are suggested by different railroad administrations as a solution to avoid these problems, they present some disadvantages which may affect track long-term performance. In this paper, a new solution designed with prefabricated reinforced concrete slabs is proposed. The aim of this solution is to guarantee a continuous and gradual track vertical stiffness transition in the vicinity of structures, overcoming granular wedges disadvantages. The aim of this study is to assess the performance of the novel wedge design by means of a 3-D FEM model and to compare it with the current solution.

  10. Prefabricated light-polymerizing plastic pattern for partial denture framework

    Directory of Open Access Journals (Sweden)

    Atsushi Takaichi

    2011-01-01

    Full Text Available Our aim is to report an application of a prefabricated light-polymerizing plastic pattern to construction of removable partial denture framework without the use of a refractory cast. A plastic pattern for the lingual bar was adapted on the master cast of a mandibular Kennedy class I partially edentulous patient. The pattern was polymerized in a light chamber. Cobalt-chromium wires were employed to minimize the potential distortion of the plastic framework. The framework was carefully removed from the master cast and invested with phosphate-bonded investment for the subsequent casting procedures. A retentive clasp was constructed using 19-gauge wrought wire and was welded to the framework by means of laser welding machine. An excellent fit of the framework in the patient′s mouth was observed in the try-in and the insertion of the denture. The result suggests that this method minimizes laboratory cost and time for partial denture construction.

  11. Marine Spongin: Naturally Prefabricated 3D Scaffold-Based Biomaterial

    Science.gov (United States)

    Jesionowski, Teofil; Norman, Małgorzata; Żółtowska-Aksamitowska, Sonia; Petrenko, Iaroslav; Ehrlich, Hermann

    2018-01-01

    The biosynthesis, chemistry, structural features and functionality of spongin as a halogenated scleroprotein of keratosan demosponges are still paradigms. This review has the principal goal of providing thorough and comprehensive coverage of spongin as a naturally prefabricated 3D biomaterial with multifaceted applications. The history of spongin’s discovery and use in the form of commercial sponges, including their marine farming strategies, have been analyzed and are discussed here. Physicochemical and material properties of spongin-based scaffolds are also presented. The review also focuses on prospects and trends in applications of spongin for technology, materials science and biomedicine. Special attention is paid to applications in tissue engineering, adsorption of dyes and extreme biomimetics. PMID:29522478

  12. Design and development of Building energy simulation Software for prefabricated cabin type of industrial building (PCES)

    Science.gov (United States)

    Zhang, Jun; Li, Ri Yi

    2018-06-01

    Building energy simulation is an important supporting tool for green building design and building energy consumption assessment, At present, Building energy simulation software can't meet the needs of energy consumption analysis and cabinet level micro environment control design of prefabricated building. thermal physical model of prefabricated building is proposed in this paper, based on the physical model, the energy consumption calculation software of prefabricated cabin building(PCES) is developed. we can achieve building parameter setting, energy consumption simulation and building thermal process and energy consumption analysis by PCES.

  13. Foot Problems

    Science.gov (United States)

    ... early. Start OverDiagnosisThe cause may be FEMORAL ANTEVERSION, TIBIAL TORSION or METATARSUS ADDUCTUS, commonly called intoeing. Self CareSee your doctor. Start OverDiagnosisYou may have a STRESS FRACTURE of the bones in your foot. The pain ...

  14. Foot pain

    Science.gov (United States)

    ... that you were born with or develops later Injury Shoes that fit poorly or do not have much cushioning Too much walking or other sports activity Trauma The following can cause foot pain: Arthritis and gout . Common in the big toe, which becomes red, swollen, ...

  15. Development of a contour meter

    International Nuclear Information System (INIS)

    Andrada C, F.A.; Sanz, D.E.

    2006-01-01

    The dosimetric calculation in patients that receive radiotherapy treatment it requires the one knowledge of the geometry of some anatomical portions, which differs from a patient to another. Making reference to the specific case of mammary neoplasia, one of the measurements that is carried out on the patient is the acquisition of the contour of the breast, which is determined from a point marked on the breastbone until another point marked on the lateral of the thorax, below the armpit, with the patient located in the irradiation position. This measurement is carried out with the help of a mechanical contour meter that is a device conformed by a series of wires with a polymeric coating, which support on the breast of the patient and it reproduces its form. Then it is transported in the more careful possible form on a paper and the contour is traced with a tracer one. The geometric error associated to this procedure is of ±1 cm, which is sensitive of being reduced. The present work finds its motivation in the patient's radiological protection radiotherapy. The maximum error in dose allowed in radiotherapeutic treatments is 5%. It would be increase the precision and with it to optimize the treatment received by the patient, reducing the error in the acquisition process of the mammary contour. With this objective, a digital device is designed whose operation is based in the application of a spatial transformation on a picture of the mammary contour, which corrects the geometric distortion introduced in the process of the photographic acquisition. An algorithm that allows to obtain a front image (without distortion) of the plane of the contour was developed. A software tool especially developed carries out the processing of the digital images. The maximum geometric error detected in the validation process is 2 mm located on a small portion of the contour. (Author)

  16. The influence of automation on tumor contouring

    NARCIS (Netherlands)

    Aselmaa, A.; van Herk, Marcel; Song, Y.; Goossens, R.H.M.; Laprie, Anne

    2017-01-01

    Fully or semi-automatic contouring tools are increasingly being used in the tumor contouring task for radiotherapy. While the fully automatic contouring tools have not reached sufficient efficiency, the semi-automatic contouring tools balance more effectively between the human interaction and

  17. Orientation-crowding within contours.

    Science.gov (United States)

    Glen, James C; Dakin, Steven C

    2013-07-15

    We examined how crowding (the breakdown of object recognition in the periphery caused by interference from "clutter") depends on the global arrangement of target and distracting flanker elements. Specifically we probed orientation discrimination using a near-vertical target Gabor flanked by two vertical distractor Gabors (one above and one below the target). By applying variable (opposite-sign) horizontal offsets to the positions of the two flankers we arranged the elements so that on some trials they formed contours with the target and on others they did not. While the presence of flankers generally elevated orientation discrimination thresholds for the target we observe maximal crowding not when flanker and targets were co-aligned but when a small spatial offset was applied to flanker location, so that contours formed between flanker and targets only when the target orientation was cued. We also report that observers' orientation judgments are biased, with target orientation appearing either attracted or repulsed by the global/contour orientation. A second experiment reveals that the sign of this effect is dependent both on observer and on eccentricity. In general, the magnitude of repulsion is reduced with eccentricity but whether this becomes attraction (of element orientation to contour orientation) is dependent on observer. We note however that across observers and eccentricities, the magnitude of repulsion correlates positively with the amount of release from crowding observed with co-aligned targets and flankers, supporting the notion of fluctuating bias as the basis for elevated crowding within contours.

  18. Research on Investment Risk Management of Chinese Prefabricated Construction Projects Based on a System Dynamics Model

    Directory of Open Access Journals (Sweden)

    Ming Li

    2017-09-01

    Full Text Available Prefabricated construction, a new direction for the future development of the Chinese construction industry, can maximize the requirements of “green”. As a new form of green building, prefabricated construction is of particular interest. On account of the immature development of the green building market in China, the investment risk for prefabricated construction is higher than for traditional architecture. Hence, it is especially important to improve its investment risk identification and management. This study adopts system dynamics and builds a risk identification feedback chart and risk flow chart, to comprehensively identify investment risks that projects in China may face and to process quantitative estimation of investment risk factors. Key factors influencing project investment risks are found, and corresponding measures are pointedly proposed. This paper may provide guidance and a reference for promoting the sound development of prefabricated construction in China.

  19. Load-carrying capacity of lightly reinforced, prefabricated walls of lightweight aggregate concrete with open structure

    DEFF Research Database (Denmark)

    Goltermann, Per

    2009-01-01

    The paper presents and evaluates the results of a coordinated testing of prefabricated, lightly reinforced walls of lightweight aggregate concrete with open structure. The coordinated testing covers all wall productions in Denmark and will therefore provide a representative assessment...

  20. The prefabricated building risk decision research of DM technology on the basis of Rough Set

    Science.gov (United States)

    Guo, Z. L.; Zhang, W. B.; Ma, L. H.

    2017-08-01

    With the resources crises and more serious pollution, the green building has been strongly advocated by most countries and become a new building style in the construction field. Compared with traditional building, the prefabricated building has its own irreplaceable advantages but is influenced by many uncertainties. So far, a majority of scholars have been studying based on qualitative researches from all of the word. This paper profoundly expounds its significance about the prefabricated building. On the premise of the existing research methods, combined with rough set theory, this paper redefines the factors which affect the prefabricated building risk. Moreover, it quantifies risk factors and establish an expert knowledge base through assessing. And then reduced risk factors about the redundant attributes and attribute values, finally form the simplest decision rule. This simplest decision rule, which is based on the DM technology of rough set theory, provides prefabricated building with a controllable new decision-making method.

  1. LOGISTICS RISK RESEARCH OF PREFABRICATED HOUSE CONSTRUCTION ENGINEERING BASED ON CREDIBILITY METHOD

    Directory of Open Access Journals (Sweden)

    Xiaoping Bai

    2017-07-01

    Full Text Available In recent years, the prefabricated house industry has rapid development,.Because of fewer suppliers, higher demand transport scheme and complex quality test, the risks of construction engineering logistics links are relatively high. Studying how to effectively evaluate the risks of construction engineering logistics links is significant. According to the characteristics of the prefabricated house construction engineering, we analyse the construction engineering logistics risks and use the combined weights method to determine the weight of indexes which contains both subjective and objective factors, to improve the scientific value and the validity of the assessment. Based on credibility measure method, a new logistics risk evaluation model in prefabricated housing is established to estimate the risk during making prefabricated house construction engineering. The presented model can avoid the subjectivity of selecting the membership function and solve the problem of how to comprehensively assess the construction engineering logistics risk in a certain extent.

  2. Mycetoma foot

    Directory of Open Access Journals (Sweden)

    Somnath Gooptu

    2013-01-01

    Full Text Available Mycetoma is an uncommon chronic granulomatous infective disease of the skin, dermis and subcutaneous tissues predominantly seen in tropical countries. A patient presented to our hospital with the swelling of the left foot with a healed sinus and a painful nodule. He gave a history of sinuses in the left foot from which there was discharge of yellow granules. Culture of the ultrasound guided fine needle aspiration cytology of the nodule revealed growths of Nocardia species. The patient was treated with a multi-drug therapy along with debridement of the painful nodule. He experienced symptomatic relief and a regression of the swelling within the three months of follow-up so far. Due to the relatively slow progression of the disease, patients are diagnosed at a late stage. Hence, emphasis should be placed on health education and the importance of wearing footwear.

  3. Prefabricated RM Façade Panels - Search for the Safe Solution

    Science.gov (United States)

    Hulimka, Jacek; Kubica, Jan; Kałuża, Marta; Galman, Iwona

    2017-10-01

    The problem, which appeared during the design works on the untypical masonry openwork of the front elevation of the academic building in Poland was presented and discussed in this paper. The original solution of masonry external façade was too risky and practically impossible for realization from the workmanship point of view. For this reason authors were proposed to make this elevation wall as prefabricated construction consisted of medium scale prefabricated elevation panels made of openwork clinker units and masonry joints with reinforcement. Two solutions of prefabricated panels were elaborated: first by the design office and second one, significantly modified, proposed by the authors. Taking into consideration fact that proposed prefabricated panels are not the typical reinforced masonry possible to design based on Eurocode 6, the methodology of “supporting design by test” was accepted to verify the correctness of proposed solutions. The carried out tests of both types of prefabricated panels with results and their discussion are also presented here. The results have shown the lack of safety for the first type of prefabricates and good behaviour, safety and durability of the final, modified solution.

  4. Automated consensus contour building for prostate MRI.

    Science.gov (United States)

    Khalvati, Farzad

    2014-01-01

    Inter-observer variability is the lack of agreement among clinicians in contouring a given organ or tumour in a medical image. The variability in medical image contouring is a source of uncertainty in radiation treatment planning. Consensus contour of a given case, which was proposed to reduce the variability, is generated by combining the manually generated contours of several clinicians. However, having access to several clinicians (e.g., radiation oncologists) to generate a consensus contour for one patient is costly. This paper presents an algorithm that automatically generates a consensus contour for a given case using the atlases of different clinicians. The algorithm was applied to prostate MR images of 15 patients manually contoured by 5 clinicians. The automatic consensus contours were compared to manual consensus contours where a median Dice similarity coefficient (DSC) of 88% was achieved.

  5. Towards Stabilizing Parametric Active Contours

    DEFF Research Database (Denmark)

    Liu, Jinchao; Fan, Zhun; Olsen, Søren Ingvor

    2014-01-01

    Numerical instability often occurs in evolving of parametric active contours. This is mainly due to the undesired change of parametrization during evolution. In this paper, we propose a new tangential diffusion term to compensate this undesired change. As a result, the parametrization will converge...

  6. From Inpainting to Active Contours

    DEFF Research Database (Denmark)

    Lauze, Francois Bernard; Nielsen, Mads

    2008-01-01

    state equation). The contour evolution is implemented in the framework of level sets. Finally, the proposed method is validated on various examples. We focus among others in the segmentation of calcified plaques observed in radiographs from human lumbar aortic regions. Keywords  Segmentation - Inpainting - Active...

  7. Consolidation by Prefabricated Vertical Drains with a Threshold Gradient

    Directory of Open Access Journals (Sweden)

    Xiao Guo

    2014-01-01

    Full Text Available This paper shows the development of an approximate analytical solution of radial consolidation by prefabricated vertical drains with a threshold gradient. To understand the effect of the threshold gradient on consolidation, a parametric analysis was performed using the present solution. The applicability of the present solution was demonstrated in two cases, wherein the comparisons with Hansbo’s results and observed data were conducted. It was found that (1 the flow with the threshold gradient would not occur instantaneously throughout the whole unit cell. Rather, it gradually occurs from the vertical drain to the outside; (2 the moving boundary would never reach the outer radius of influence if R+1

  8. Disperse reinforced concrete used in obtaining prefabricated elements for roads

    Directory of Open Access Journals (Sweden)

    Bogdan MEZEI

    2014-07-01

    Full Text Available Concrete is the most used material in construction. By improving the performance of materials and of technologies, concretes with outstanding performances were also developed, in the past two decades. Concrete with dispersed reinforcement represents a new generation of reinforced concrete that combines a good behavior of concrete compressive strength with an increased tensile strength of steel fibers. Using this material, monolithic and prefabricated concrete elements with high mechanical strengths and high durability can be obtained. Technological processes for preparation of concrete with dispersed reinforcement are similar to the conventional methods and do not involve using additional equipment for dosing the dispersed reinforcement. The study aimed the development of road plates made with optimized disperse- reinforced concrete. The first tests were done on plates from the gutter roadway, having a classic reinforcement, using different percentages of fibre reinforcement in the concrete composition, leading to the development of a new optimized economical solution. The results prove the enhanced characteristics of the disperse-reinforced concrete versus conventional concrete, and hence of the developed concrete plates.

  9. Reconstruction of bony facial contour deficiencies with polymethylmethacrylate implants: case report

    Directory of Open Access Journals (Sweden)

    Ruy C. C. Abdo Filho

    2011-08-01

    Full Text Available Facial trauma can be considered one of the most serious aggressions found in the medical centers due to the emotional consequences and the possibility of deformity. In craniofacial surgery, the use of autologous bone is still the first choice for reconstructing bony defects or irregularities. When there is a shortage of donor bone or a patient refuses an intracranial operation, alloplastic materials such as polymethylmethacrylate (PMMA can be used. The PMMA prosthesis can be pre-fabricated, bringing advantages such as reduction of surgical time, easy technical handling and good esthetic results. This paper describes the procedures for rehabilitating a patient with PMMA implants in the region of the face, recovering the facial contours and esthetics of the patient.

  10. Investigation on Prefabricated Building System Skilled Component Installers

    Directory of Open Access Journals (Sweden)

    Nurul Rezuana Buyung

    2013-09-01

    Full Text Available In the face of an increasingly challenging era of globalization, skills and new equipments which includes prefabricated building components, known as Industrialized Building System (IBS has been introduced towards achievement of sustainable construction. IBS is a construction system in which the components are manufactured in a factory, on or off site, positioned and assembled into complete structures with minimal additional site work. IBS requires high construction precision and needs a higher skill level of workers. Compared to the conventional construction method, the skill level of IBS workers is more demanding. Although there are a lot benefits in implementing IBS, the construction industry still not rapidly implementing IBS. The IBS method still considered new and even though there are a lot of benefits it still faces barriers. In an IBS construction, the role of the contractor is shifted from a builder to an assembler on the site. Therefore, this requires the contractor to be prepared technologically with IBS knowledge and skills. It is generally perceived that the number of skilled IBS installers in Malaysia is still low even though the system has been implemented for a long time. This research is carried out to find out whether the existing number of IBS installer is sufficient. Primary data was collected by carrying out interviews with the contractors at the IBS construction site in Penang Island in order to get the contractor’s feedback regarding this issue. Meanwhile, the secondary data was collected from government agencies to get the number of existing IBS installer and the number of IBS projects done in government projects. The results from this study indicated that not all categories of skill workers are in shortage. However, the number of precast concrete installer is in a critical shortage.

  11. Timber Chips as the Insulation Material for Energy Saving in Prefabricated Offices

    Directory of Open Access Journals (Sweden)

    Yupeng Wang

    2016-06-01

    Full Text Available This research demonstrates the feasibility of a roof insulation method for prefabricated offices that uses vinyl packed timber chips to reduce air conditioning loads (hereinafter referred to as AC loads and which also improves indoor thermal comfort. The advantages of the new roof insulation method were revealed through comparing the impacts of four roof types on prefabricated offices. The AC load and indoor thermal comfort (surface temperature and air temperature were evaluated. The disposal of scrap timber discarded from building construction projects is costing money, and is also a waste of natural resources. The assessment of a new roof insulation method with timber chips demonstrates the advanced usage of timber chips, reducing the environmental load in the building construction process. On the other hand, since prefabricated offices have lower thermal storage capacities and are less airtight than RC (reinforced concrete or S (steel structured buildings, the AC load consumption and indoor thermal comfort exacerbation in prefabricated offices is more serious. Especially in summer, a large amount of solar energy absorption from the roof raises the indoor air temperature and significantly increases the cooling load. This research contributes to the environmental design for prefabricated offices, and develops a method for the reuse of wood chips.

  12. Application of Prefabricated Panels for the Energy Retrofit of Portuguese Residential Buildings Facades: A Case Study

    Directory of Open Access Journals (Sweden)

    Sousa J.

    2013-09-01

    Full Text Available This article aims to evaluate the potential application of prefabricated panels in energy retrofit of facades in the Portuguese building stock. The fundamentals of this study were part of Annex 50, which was an international ECBCS IEA project, with the purpose of developing an innovative concept of building renovation for the most representative buildings based on prefabricated systems. To analyze the potential application of energy retrofit using prefabricated panels, was important to know the reality of the existing building stock and its morphology. To know the reality of the building stock, an analysis was done based on the existing statistical data and to find the most representative residential buildings, target of the study, three criteria were defined: buildings built before 1990, with 2 to 6 floors and with renovation needs in the exterior envelope.

  13. Prefabrication of a vascularized nerve graft by vessel implantation: preliminary report of an experimental model.

    Science.gov (United States)

    Cavadas, P C; Vera-Sempere, F J

    1994-01-01

    Regeneration through vascularized nerve grafts (VNG) seems to be better than nonvascularized nerve grafts (NVNG), especially in hostile beds. We report on an experimental technique of prefabrication of VNG by direct vessel implantation. An arteriovenous fistula was created in the groin region with autologous vein grafts in the Wistar rat model, and implanted into the sciatic nerve. Five weeks later the sciatic VNG was elevated on the prefabricated pedicle. The flap was free-transferred orthotopically over a silicone sheet to impede plasmatic imbibition. Flap viability at 3 days was complete. India ink injection of the AV fistula resulted in capillary ink filling within the nerve and surrounding tissues. Histologic sections of the flap were examined, revealing its neovascularity. In an ongoing study, the regeneration through this prefabricated VNG is being compared to native VNG.

  14. Practical and safe implementation of disposal with prefabricated EBS modules

    International Nuclear Information System (INIS)

    Kawamura, Hideki; McKinley, Ian G.; Neall, Fiona B.

    2008-01-01

    The use of prefabricated EBS modules ('PEMs') to minimise the problems involved with handling compacted bentonite and ensuring that it is emplaced to established quality levels has been investigated in various national programmes for disposal of both HLW and SF. To date, however, this has tended to be decoupled from studies of related operational aspects such as assessing / minimising the consequences of use of concrete for support structures, ensuring ease of tele-operated reversal of waste packages during emplacement (e.g. in the event of operational disturbances) / retrieval at a later time, logistical optimisation (especially for programmes with large waste inventories) and cost minimisation. It is clear that specific aspects of operational safety and practicality can be considerably enhanced if designs are modified with a focus on them. It is trickier to provide optimised solutions, which simultaneously address all these critical points. Nevertheless, with a bit of lateral thinking, it appears possible to devise options that may not only ease the operational phase, but may also actually improve post-closure safety case robustness - although improved, more realistic performance assessment codes and databases will be needed to demonstrate this rigorously. To illustrate this approach, an example will be presented based of disposal of vitrified HLW in a fractured hard rock; the general principles involved are, however, also applicable to other higher activity wastes and other host rocks. Key aspects of the design are: Optimisation of PEM design for both short-term and long-term performance; Development of a rail emplacement system which eases remote handled emplacement / recovery; Large diameter, lined emplacement tunnels to ensure operational robustness; Use of multi-package overpacks (e.g. 6 HLW containers in each PEM) and short tunnels to ease emplacement logistics; and Backfilling with a non-swelling sacrificial pH buffer (eases handling and improves

  15. An alternative method for facial resurfacing: supraclavicular skin prefabrication by perforator fascia flap.

    Science.gov (United States)

    Hocaoğlu, Emre

    2014-01-01

    Prefabrication of supraclavicular skin provides a useful source for flaps congruent with the face skin. Among various vascular sources that have been used for this purpose, anterolateral thigh fascia seems to represent a greater value because of having a long and strong vascular pedicle and negligible donor-site morbidity. In this regard, we present a technical report on using the lateral circumflex femoral artery perforator flap harvest technique in preparing an anterolateral thigh fascia flap for the prefabrication of the supraclavicular skin. The technique proved successful in resurfacing the facial skin of a young female patient with a giant congenital melanocytic hairy nevus on the left side of her face.

  16. An improved spatial contour tree constructed method

    Science.gov (United States)

    Zheng, Yi; Zhang, Ling; Guilbert, Eric; Long, Yi

    2018-05-01

    Contours are important data to delineate the landform on a map. A contour tree provides an object-oriented description of landforms and can be used to enrich the topological information. The traditional contour tree is used to store topological relationships between contours in a hierarchical structure and allows for the identification of eminences and depressions as sets of nested contours. This research proposes an improved contour tree so-called spatial contour tree that contains not only the topological but also the geometric information. It can be regarded as a terrain skeleton in 3-dimention, and it is established based on the spatial nodes of contours which have the latitude, longitude and elevation information. The spatial contour tree is built by connecting spatial nodes from low to high elevation for a positive landform, and from high to low elevation for a negative landform to form a hierarchical structure. The connection between two spatial nodes can provide the real distance and direction as a Euclidean vector in 3-dimention. In this paper, the construction method is tested in the experiment, and the results are discussed. The proposed hierarchical structure is in 3-demintion and can show the skeleton inside a terrain. The structure, where all nodes have geo-information, can be used to distinguish different landforms and applied for contour generalization with consideration of geographic characteristics.

  17. Enhancement of Afterimage Colors by Surrounding Contours

    Directory of Open Access Journals (Sweden)

    Takao Sato

    2011-05-01

    Full Text Available Presenting luminance contours surrounding the adapted areas in test phase enhances color afterimages in both duration and color appearance. The presence of surrounding contour is crucial to some color phenomenon such as van Lier's afterimage, but the contour-effect itself has not been seriously examined. In this paper, we compared the contour-effect to color afterimages and to actually colored patches to examine the nature of color information subserving color-aftereffect. In the experiment, observers were adapted for 1 sec to a small colored square (red, green, yellow, or blue presented on a gray background. Then, a test field either with or without surrounding contour was presented. Observers matched the color of a test-patch located near the afterimage to the color of afterimage. It was found that the saturation of negative afterimage was almost doubled by the presence of surrounding contours. There was no effect of luminance contrast or polarity of contours. In contrast, no enhancement of saturation by surrounding contours was observed for actually colored patches even though the colors of patches were equalized to that of afterimage without contours. This dissociation in the contour-effect demonstrates the crucial difference between the color information for aftereffects and for ordinary bottom-up color perception.

  18. Brightness Alteration with Interweaving Contours

    Directory of Open Access Journals (Sweden)

    Sergio Roncato

    2012-12-01

    Full Text Available Chromatic induction is observed whenever the perceived colour of a target surface shifts towards the hue of a neighbouring surface. Some vivid manifestations may be seen in a white background where thin coloured lines have been drawn (assimilation or when lines of different colours are collinear (neon effect or adjacent (watercolour to each other. This study examines a particular colour induction that manifests in concomitance with an opposite effect of colour saturation (or anti-spread. The two phenomena can be observed when a repetitive pattern is drawn in which outline thin contours intercept wider contours or surfaces, colour spreading appear to fill the surface occupied by surfaces or thick lines whereas the background traversed by thin lines is seen as brighter or filled of a saturated white. These phenomena were first observed by Bozzi (1975 and Kanizsa (1979 in figural conditions that did not allow them to document their conjunction. Here we illustrate various manifestations of this twofold phenomenon and compare its effects with the known effects of brightness and colour induction. Some conjectures on the nature of these effects are discussed.

  19. Clinical workflow for personalized foot pressure ulcer prevention.

    Science.gov (United States)

    Bucki, M; Luboz, V; Perrier, A; Champion, E; Diot, B; Vuillerme, N; Payan, Y

    2016-09-01

    Foot pressure ulcers are a common complication of diabetes because of patient's lack of sensitivity due to neuropathy. Deep pressure ulcers appear internally when pressures applied on the foot create high internal strains nearby bony structures. Monitoring tissue strains in persons with diabetes is therefore important for an efficient prevention. We propose to use personalized biomechanical foot models to assess strains within the foot and to determine the risk of ulcer formation. Our workflow generates a foot model adapted to a patient's morphology by deforming an atlas model to conform it to the contours of segmented medical images of the patient's foot. Our biomechanical model is composed of rigid bodies for the bones, joined by ligaments and muscles, and a finite element mesh representing the soft tissues. Using our registration algorithm to conform three datasets, three new patient models were created. After applying a pressure load below these foot models, the Von Mises equivalent strains and "cluster volumes" (i.e. volumes of contiguous elements with strains above a given threshold) were measured within eight functionally meaningful foot regions. The results show the variability of both location and strain values among the three considered patients. This study also confirms that the anatomy of the foot has an influence on the risk of pressure ulcer. Copyright © 2016. Published by Elsevier Ltd.

  20. Foot morphometric phenomena.

    Science.gov (United States)

    Agić, Ante

    2007-06-01

    Knowledge of the foot morphometry is important for proper foot structure and function. Foot structure as a vital part of human body is important for many reasons. The foot anthropometric and morphology phenomena are analyzed together with hidden biomechanical descriptors in order to fully characterize foot functionality. For Croatian student population the scatter data of the individual foot variables were interpolated by multivariate statistics. Foot morphometric descriptors are influenced by many factors, such as life style, climate, and things of great importance in human society. Dominant descriptors related to fit and comfort are determined by the use 3D foot shape and advanced foot biomechanics. Some practical recommendations and conclusions for medical, sportswear and footwear practice are highlighted.

  1. A Method for Denoising Image Contours

    Directory of Open Access Journals (Sweden)

    Ovidiu COSMA

    2017-12-01

    Full Text Available The edge detection techniques have to compromise between sensitivity and noise. In order for the main contours to be uninterrupted, the level of sensitivity has to be raised, which however has the negative effect of producing a multitude of insignificant contours (noise. This article proposes a method of removing this noise, which acts directly on the binary representation of the image contours.

  2. Carbon Reduction Measures-Based LCA of Prefabricated Temporary Housing with Renewable Energy Systems

    Directory of Open Access Journals (Sweden)

    Ling Dong

    2018-03-01

    Full Text Available Temporary housing plays an important role in providing secure, hygienic, private, and comfortable shelter in the aftermath of disaster (such as flood, fire, earthquake, etc.. Additionally, temporary housing can also be used as a sustainable form of on-site residences for construction workers. While most of the building components used in temporary housing can be manufactured in a plant, prefabrication technology improves the production efficiency of temporary housing; furthermore, integrated renewable energy systems, for example, solar photovoltaic (PV system, offer benefits for temporary housing operations. In order to assess the environmental impacts of prefabricated temporary housing equipped with renewable energy systems, this study first divides the life cycle of temporary housing into six stages, and then establishes a life cycle assessment (LCA model for each stage. Furthermore, with the aim of reducing the environmental impacts, life cycle carbon reduction measures are proposed for each stage of temporary housing. The proposed methodology is demonstrated using a case study in China. Based on the proposed carbon reduction measures, the LCA of a prefabricated temporary housing case study building equipped with renewable energy systems indicates a carbon emissions intensity of 35.7 kg/m2·per year, as well as a reduction in material embodied emissions of 18%, assembly emissions of 17.5%, and operational emissions of 91.5%. This research proposes a carbon reduction-driven LCA of temporary housing and contributes to promoting sustainable development of prefabricated temporary housing equipped with renewable energy systems.

  3. Optimization of concrete for prefabrication and quantification of its environmental impact

    NARCIS (Netherlands)

    Onghena, S.; Grunewald, S.; Schutter, G

    2016-01-01

    The development of strength is an important criterion for the production of
    prefabricated concrete elements. With seasonal changes of temperature that affect the development of concrete strength, daily cycles of often 18 hours or shorter have to bemaintained. The use of Ordinary Portland Cement

  4. Quantifying the waste reduction potential of using prefabrication in building construction in Hong Kong.

    Science.gov (United States)

    Jaillon, L; Poon, C S; Chiang, Y H

    2009-01-01

    As Hong Kong is a compact city with limited available land and high land prices, the construction of high-rise buildings is prevalent. The construction industry produces a significant amount of building waste. In 2005, about 21.5 million tonnes of construction waste were generated, of which 11% was disposed of in landfills and 89% in public filling areas. At the present rate, Hong Kong will run out of both public filling areas and landfill space within the next decade. The government is taking action to tackle the problem, such as by introducing a construction waste landfill charge, and promoting prefabrication to reduce on-site waste generation. This paper reports an ongoing study on the use of prefabrication in buildings and its impact on waste reduction in Hong Kong. A questionnaire survey was administered to experienced professionals, and case studies of recently completed building projects were conducted. The results revealed that construction waste reduction is one of the major benefits when using prefabrication compared with conventional construction. The average wastage reduction level was about 52%. This implies that a wider use of prefabrication could considerably reduce construction waste generation in Hong Kong and alleviate the burdens associated with its management.

  5. Evaluation of torque loss value of MAD/MAM zirconia abutments with prefabricated titanium abutments

    Directory of Open Access Journals (Sweden)

    Marzieh Alikhasi

    2013-04-01

    Full Text Available Background and Aims: In response to esthetic demand of patients, ceramic abutments have been developed. Despite esthetic of zirconia abutments, machining accuracy of these abutments has always been a question. Any misfit in the abutment-implant interface connection can lead to detorque and screw loosening. The aim of this study was to compare torque loss value of manually aided design/manually aided manufacture (MAD/MAM zirconia abutments with prefabricated titanium abutments. Materials and Methods: Seven titanium abutments (Branemark RP, Easy abutment and seven copy milled abutments which were duplicated from the prefabricated Zirkonzhan (ZirkonZahn, Sand in Taufers, Italy were prepared. After sintering process of zirconia abutment, all abutments were fastened with a torque screw under 35 Ncm. Detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean torque loss were calculated and compared using Student's t test. Results: The mean of torque loss was 12.71 Ncm with standard deviation of 1.70 for prefabricated titanium abutments and 15.50 Ncm with standard deviation of 4.67 for MAD-MAM abutments. The difference between the two groups was not statistically significant (P=0.23. Conclusion: Within the limitation of this study, MAD-MAM ceramic abutments could maintain the applied torque comparing to the prefabricated abutments.

  6. Prefabricated floor panels composed of fiber reinforced concrete and a steel substructure

    DEFF Research Database (Denmark)

    Lárusson, Lárus H.; Fischer, Gregor; Jönsson, Jeppe

    2013-01-01

    This paper reports on a study on prefabricated composite and modular floor deck panels composed of relatively thin fiber reinforced concrete slabs connected to steel substructures. The study focuses on the design, manufacturing, structural improvements and behavior of the floor systems during...

  7. Contouring variability of human- and deformable-generated contours in radiotherapy for prostate cancer

    International Nuclear Information System (INIS)

    Gardner, Stephen J; Wen, Ning; Kim, Jinkoo; Liu, Chang; Pradhan, Deepak; Aref, Ibrahim; Cattaneo, Richard II; Vance, Sean; Movsas, Benjamin; Chetty, Indrin J; Elshaikh, Mohamed A

    2015-01-01

    This study was designed to evaluate contouring variability of human-and deformable-generated contours on planning CT (PCT) and CBCT for ten patients with low-or intermediate-risk prostate cancer. For each patient in this study, five radiation oncologists contoured the prostate, bladder, and rectum, on one PCT dataset and five CBCT datasets. Consensus contours were generated using the STAPLE method in the CERR software package. Observer contours were compared to consensus contour, and contour metrics (Dice coefficient, Hausdorff distance, Contour Distance, Center-of-Mass [COM] Deviation) were calculated. In addition, the first day CBCT was registered to subsequent CBCT fractions (CBCTn: CBCT2–CBCT5) via B-spline Deformable Image Registration (DIR). Contours were transferred from CBCT1 to CBCTn via the deformation field, and contour metrics were calculated through comparison with consensus contours generated from human contour set. The average contour metrics for prostate contours on PCT and CBCT were as follows: Dice coefficient—0.892 (PCT), 0.872 (CBCT-Human), 0.824 (CBCT-Deformed); Hausdorff distance—4.75 mm (PCT), 5.22 mm (CBCT-Human), 5.94 mm (CBCT-Deformed); Contour Distance (overall contour)—1.41 mm (PCT), 1.66 mm (CBCT-Human), 2.30 mm (CBCT-Deformed); COM Deviation—2.01 mm (PCT), 2.78 mm (CBCT-Human), 3.45 mm (CBCT-Deformed). For human contours on PCT and CBCT, the difference in average Dice coefficient between PCT and CBCT (approx. 2%) and Hausdorff distance (approx. 0.5 mm) was small compared to the variation between observers for each patient (standard deviation in Dice coefficient of 5% and Hausdorff distance of 2.0 mm). However, additional contouring variation was found for the deformable-generated contours (approximately 5.0% decrease in Dice coefficient and 0.7 mm increase in Hausdorff distance relative to human-generated contours on CBCT). Though deformable contours provide a reasonable starting point for contouring

  8. Ottawa Panel Evidence-Based Clinical Practice Guidelines for Foot Care in the Management of Juvenile Idiopathic Arthritis.

    Science.gov (United States)

    Brosseau, Lucie; Toupin-April, Karine; Wells, George; Smith, Christine A; Pugh, Arlanna G; Stinson, Jennifer N; Duffy, Ciarán M; Gifford, Wendy; Moher, David; Sherrington, Catherine; Cavallo, Sabrina; De Angelis, Gino; Loew, Laurianne; Rahman, Prinon; Marcotte, Rachel; Taki, Jade; Bisaillon, Jacinthe; King, Judy; Coda, Andrea; Hendry, Gordon J; Gauvreau, Julie; Hayles, Martin; Hayles, Kay; Feldman, Brian; Kenny, Glen P; Li, Jing Xian; Briggs, Andrew M; Martini, Rose; Feldman, Debbie Ehrmann; Maltais, Désirée B; Tupper, Susan; Bigford, Sarah; Bisch, Marg

    2016-07-01

    To create evidence-based guidelines evaluating foot care interventions for the management of juvenile idiopathic arthritis (JIA). An electronic literature search of the following databases from database inception to May 2015 was conducted: MEDLINE (Ovid), EMBASE (Ovid), Cochrane CENTRAL, and clinicaltrials.gov. The Ottawa Panel selection criteria targeted studies that assessed foot care or foot orthotic interventions for the management of JIA in those aged 0 to ≤18 years. The Physiotherapy Evidence Database scale was used to evaluate study quality, of which only high-quality studies were included (score, ≥5). A total of 362 records were screened, resulting in 3 full-text articles and 1 additional citation containing supplementary information included for the analysis. Two reviewers independently extracted study data (intervention, comparator, outcome, time period, study design) from the included studies by using standardized data extraction forms. Directed by Cochrane Collaboration methodology, the statistical analysis produced figures and graphs representing the strength of intervention outcomes and their corresponding grades (A, B, C+, C, C-, D+, D, D-). Clinical significance was achieved when an improvement of ≥30% between the intervention and control groups was present, whereas P>.05 indicated statistical significance. An expert panel Delphi consensus (≥80%) was required for the endorsement of recommendations. All included studies were of high quality and analyzed the effects of multidisciplinary foot care, customized foot orthotics, and shoe inserts for the management of JIA. Custom-made foot orthotics and prefabricated shoe inserts displayed the greatest improvement in pain intensity, activity limitation, foot pain, and disability reduction (grades A, C+). The use of customized foot orthotics and prefabricated shoe inserts seems to be a good choice for managing foot pain and function in JIA. Copyright © 2016 American Congress of Rehabilitation

  9. Contours of New Economic Theory

    Directory of Open Access Journals (Sweden)

    Garry Jacobs

    2015-05-01

    Full Text Available The need for a paradigm change in economic thought has been well established, but the contours and fundamental characteristics of a new paradigm in economic theory are yet to be worked out. This article views this transition as an inevitable expression of the maturation of the social sciences into an integrated trans-disciplinary science of society founded on common underlying principles, premises and processes. It calls for evolution of human-centered, value-based economic theory whose objective is to maximize human economic security, welfare and well-being rather than economic growth. It emphasizes the determinative role of fundamental creative social processes expressing in all fields of human endeavor. It argues for extending the boundaries of economics to encompass the entire gamut of political, legal, social, psychological, intellectual, organizational and ecological factors that directly and indirectly contribute to economic security, welfare and well-being. The article concludes with a list of anticipated practical implications.

  10. Calculation of prefabricated part of WWR-K reactor building

    International Nuclear Information System (INIS)

    Belyashova, N.N.; Aptikaev, F.F.; Kopnichev, Yu.F.

    1998-01-01

    According of factual characteristics a strength and deformation of over-land part of carrier constructions under construction movement is defined. Direct dynamical calculation of design elements under action of inertial loads from supports shifts shows, that seismic stability of enclosing construction is not ensured. Possibly practically total collapse of coating construction is possibly, under which following levels of damages of internal design constructions of reactor central room have been forecasted: 1. Fall of destroyed design construction on reactor vessel in time moment (1.56-1.59 s) after coming to building of earthquake seismic waves of 10 balls. 2. It is possibly cracks formation in radial direction in lower part of reactor cap, but destroying of cap does not incident; 3. It is possibly cracks formation within stretched concrete zone of reactor construction at the mark from - 0.859 up to 0.100. Destroy of concrete's compressive zone of reactor construction have not being expected. 4. Collapse of reactor first contour coating constructions have not being expected

  11. Diabetic Foot - Multiple Languages

    Science.gov (United States)

    ... Are Here: Home → Multiple Languages → All Health Topics → Diabetic Foot URL of this page: https://medlineplus.gov/languages/ ... V W XYZ List of All Topics All Diabetic Foot - Multiple Languages To use the sharing features on ...

  12. Drawing Contour Trees in the Plane.

    Science.gov (United States)

    Heine, C; Schneider, D; Carr, Hamish; Scheuermann, G

    2011-11-01

    The contour tree compactly describes scalar field topology. From the viewpoint of graph drawing, it is a tree with attributes at vertices and optionally on edges. Standard tree drawing algorithms emphasize structural properties of the tree and neglect the attributes. Applying known techniques to convey this information proves hard and sometimes even impossible. We present several adaptions of popular graph drawing approaches to the problem of contour tree drawing and evaluate them. We identify five esthetic criteria for drawing contour trees and present a novel algorithm for drawing contour trees in the plane that satisfies four of these criteria. Our implementation is fast and effective for contour tree sizes usually used in interactive systems (around 100 branches) and also produces readable pictures for larger trees, as is shown for an 800 branch example.

  13. Evaluating a Prefabricated Submerged Breakwater and Double-T Sill for Beach Erosion Prevention, Cape May Point, NJ

    National Research Council Canada - National Science Library

    Stauble, Donald K; Giovannozzi, Michael A

    2003-01-01

    ...) and a linear prefabricated concrete sill called the Double-T across the seaward end of two adjacent groin compartments, in order to assess the effectiveness of these structures in retaining sand...

  14. Image Interpolation with Geometric Contour Stencils

    Directory of Open Access Journals (Sweden)

    Pascal Getreuer

    2011-09-01

    Full Text Available We consider the image interpolation problem where given an image vm,n with uniformly-sampled pixels vm,n and point spread function h, the goal is to find function u(x,y satisfying vm,n = (h*u(m,n for all m,n in Z. This article improves upon the IPOL article Image Interpolation with Contour Stencils. In the previous work, contour stencils are used to estimate the image contours locally as short line segments. This article begins with a continuous formulation of total variation integrated over a collection of curves and defines contour stencils as a consistent discretization. This discretization is more reliable than the previous approach and can effectively distinguish contours that are locally shaped like lines, curves, corners, and circles. These improved contour stencils sense more of the geometry in the image. Interpolation is performed using an extension of the method described in the previous article. Using the improved contour stencils, there is an increase in image quality while maintaining similar computational efficiency.

  15. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    OpenAIRE

    Kim, Chang-Soon; Duong, Hieu Pham; Park, Jung-Chul; Shin, Hyun-Seung

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-...

  16. Off-Site Prefabrication: What Does it Require from the Trade Contractor?

    DEFF Research Database (Denmark)

    Bekdik, Baris; Hall, Daniel; Aslesen, Sigmund

    2016-01-01

    The purpose of the paper is to show what is required to industrialize a building process from the standpoint of the trade contractor. Rationalization of building processes has, over the years, caught the attention of numerous IGLC papers. Although significant contributions have been made to further...... understand and improve existing construction processes, relatively few contributions have focused on the opportunities for industrialization from the trade contractor’s perspective. This paper uses an in-depth case study to address the deployment strategy for off-site fabrication techniques and processes...... at only one case study, the conclusions are limited in generalizability to other prefabrication operations. However, it represents an important in-depth case from the trade contractors’ perspective and will contribute to the growing body of research focused on industrialization and prefabrication in lean...

  17. Study on Cooperative Mechanism of Prefabricated Producers Based on Evolutionary Game Theory

    Directory of Open Access Journals (Sweden)

    Tongyao Feng

    2017-01-01

    Full Text Available Good cooperation mechanism is an important guarantee for the advancement of industrialization construction. To strengthen the partnership between producers, we analyze the behavior evolution trend of both parties using an evolutionary game theory. Based on the original model, the mechanism of coordination and cooperation between prefabricated producers is explained under the condition of punishment and incentive. The results indicate that stable evolutionary strategies exist under both cooperation and noncooperation, and the evolutionary results are influenced by the initial proportion of both decision-making processes. The government can support the production enterprises to establish a solid partnership through effective punishment and incentive mechanisms to reduce the initial cost in the supply chain of prefabricated construction, resulting in a win-win situation.

  18. Spiral Light Beams and Contour Image Processing

    Science.gov (United States)

    Kishkin, Sergey A.; Kotova, Svetlana P.; Volostnikov, Vladimir G.

    Spiral beams of light are characterized by their ability to remain structurally unchanged at propagation. They may have the shape of any closed curve. In the present paper a new approach is proposed within the framework of the contour analysis based on a close cooperation of modern coherent optics, theory of functions and numerical methods. An algorithm for comparing contours is presented and theoretically justified, which allows convincing of whether two contours are similar or not to within the scale factor and/or rotation. The advantages and disadvantages of the proposed approach are considered; the results of numerical modeling are presented.

  19. Noninvasive Body Contouring: A Male Perspective.

    Science.gov (United States)

    Wat, Heidi; Wu, Douglas C; Goldman, Mitchel P

    2018-01-01

    Noninvasive body contouring is an attractive therapeutic modality to enhance the ideal male physique. Men place higher value on enhancing a well-defined, strong, masculine jawline and developing a V-shaped taper through the upper body. An understanding of the body contour men strive for allows the treating physician to focus on areas that are of most concern to men, thus enhancing patient experience and satisfaction. This article discusses noninvasive body contouring techniques, taking into account the unique aesthetic concerns of the male patient by combining an analysis of the existing literature with our own clinical experience. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. In-Plane Strengthening Effect of Prefabricated Concrete Walls on Masonry Structures: Shaking Table Test

    OpenAIRE

    Li, Weiwei; Liu, Weiqing; Wang, Shuguang; Du, Dongsheng

    2017-01-01

    The improvement effect of a new strengthening strategy on dynamic action of masonry structure, by installing prefabricated concrete walls on the outer facades, is validated by shaking table test presented in this paper. We carried out dynamic tests of two geometrically identical five-story reduced scaled models, including an unstrengthened and a strengthened masonry model. The experimental analysis encompasses seismic performances such as cracking patterns, failure mechanisms, amplification f...

  1. Utilization of Construction Waste Composite Powder Materials as Cementitious Materials in Small-Scale Prefabricated Concrete

    OpenAIRE

    Cuizhen Xue; Aiqin Shen; Yinchuan Guo; Tianqin He

    2016-01-01

    The construction and demolition wastes have increased rapidly due to the prosperity of infrastructure construction. For the sake of effectively reusing construction wastes, this paper studied the potential use of construction waste composite powder material (CWCPM) as cementitious materials in small-scale prefabricated concretes. Three types of such concretes, namely, C20, C25, and C30, were selected to investigate the influences of CWCPM on their working performances, mechanical properties, ...

  2. Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment

    OpenAIRE

    de Jesus Tavarez, Rudys Rodolfo; Bonachela, Wellington Cardoso; Xible, Anuar Antônio

    2011-01-01

    OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricate...

  3. Evaluation of torque loss value of MAD/MAM zirconia abutments with prefabricated titanium abutments

    OpenAIRE

    Marzieh Alikhasi; Roshanak Baghaie; Nasim khosronejad

    2013-01-01

    Background and Aims: In response to esthetic demand of patients, ceramic abutments have been developed. Despite esthetic of zirconia abutments, machining accuracy of these abutments has always been a question. Any misfit in the abutment-implant interface connection can lead to detorque and screw loosening. The aim of this study was to compare torque loss value of manually aided design/manually aided manufacture (MAD/MAM) zirconia abutments with prefabricated titanium abutments. Materials and ...

  4. FEA of the Variations in Sound Insulation in Nominally Identical Prefabricated Lightweight Timber Panel Structures

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Andersen, Lars

    2013-01-01

    The measurements of sound propagation in buildings usually show a variation between nominally identical constructed structures. These variations can be due to variations in structural properties, measurement uncertainties or workmanship related factors. Better knowledge about the source...... for these variations can lead to lowered production costs. The present paper presents a numerical analysis of the variations in sound propagation of norminally identical prefabricated lightweight timber panel structues. By using the commercial FEA software ABAQUS, a parameter study is carried out regarding variation...

  5. Powerful Software to Simulate Soil Consolidation Problems with Prefabricated Vertical Drains

    OpenAIRE

    Gonzalo García-Ros; Iván Alhama; Manuel Cánovas

    2018-01-01

    The present work describes the program Simulation of Consolidation with Vertical Drains (SICOMED_2018), a tool for the solution of consolidation processes in heterogeneous soils, with totally or partially penetrating prefabricated vertical drains (PVD) and considering both the effects of the smear zone, generated when introducing the drain into the ground, and the limitation in the discharge capacity of the drain. In order to provide a completely free program, the code Next-Generation Simulat...

  6. Use of dry sludge from waste water treatment plants as an additive in prefabricated concrete brick

    OpenAIRE

    Yagüe, A.; Valls, S.; Vázquez, E.; Kuchinow, V.

    2002-01-01

    Dry sludge from the Sabadell Water Treatment Plant was used to prepare prefabricated concrete bricks. After characterising the sludge and the manufacturing process used to make the bricks, we define the conditions of addition of the sludges in the manufacture. Reference samples not containing sludge and samples containing 2 % of dry sludge by cement weight were prepared. The variation in density, porosity, absorption coefficient and compressive strength of the bricks with the presence of...

  7. Ordering Strategy Analysis of Prefabricated Component Manufacturer in Construction Supply Chain

    OpenAIRE

    Yang, Hongxiong; Chung, Jacky K. H.; Chen, Yuhong; Pan, Yifan; Mei, Zhiling; Sun, Xiongle

    2018-01-01

    Firstly, the characteristics and present situations of the prefabricated construction supply chain are analyzed; inventory cost models for construction material of every phase order, one-off order, and fractionated order are built based on traditional EOQ model and construction supply chain theory. Next, the order decision is represented in binary numbers 0 and 1, in which 0 stands for “no order” and 1 for “order.” The analysis uses the genetic algorithm, sets the objective function, and unde...

  8. Prefabricated Images in Young Children’s Text-Making at School

    Directory of Open Access Journals (Sweden)

    Charlotte Engblom

    2016-08-01

    Full Text Available In classrooms where computers are used as tools for text-making, images and photographs from e.g. Google, here called “prefabricated images”, can be selected and copied into texts and combined with writing. In this article children’s use of prefabricated images as resources for personal texts is investigated with specific focus on cohesion between the modes of image and writing. When prefabricated images occur in combination with writing about a personal experience the specific motifs shown in the image are unrelated to the text-maker, but the results of this study show that cohesion may still be obtained, for example via colour, naturalistic modality or decontextualization of the motif in the image via a close-up or a distant perspective. Copying and recontextualization of photographs are common not only in schools but also in professional settings as image banks supply images to, for example, news editors and journalists, and contemporary text creation is often characterized by “representation-as-selection” (Adami and Kress, 2010. The ability to obtain cohesion across modes can be regarded as a defining feature of success in multimodal text-making (Wyatt-Smith and Kimber, 2009, and also for the interpretation of contemporary texts.

  9. The Design of a Semi-Prefabricated LVL-Concrete Composite Floor

    Directory of Open Access Journals (Sweden)

    David Yeoh

    2012-01-01

    Full Text Available This paper describes the design of a novel semi-prefabricated LVL-concrete composite floor that has been developed in New Zealand. In this solution, the floor units made from LVL joists and plywood are prefabricated in the factory and transported to the building site. The units are then lifted onto the supports and connected to the main frames of the building and to the adjacent units. Finally, a concrete topping is poured on top of the units in order to form a continuous slab connecting all the units. Rectangular notches cut from the LVL joists and reinforced with coach screws provide the composite action between the concrete slab and the LVL joists. This system proved to be an effective modular solution that ensures rapid construction. A design procedure based on the use of the effective flexural stiffness method, also known as the “gamma method” is proposed for the design of the composite floor at ultimate and serviceability limit states, in the short and long term. By comparison with the experimental results, it is shown that the proposed method leads to conservative design. A step-by-step design worked example of this novel semi-prefabricated composite floor concludes the paper.

  10. VT Data - Lidar 1ft Contours

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) This metadata applies to contours derived from Quality Level 2 (QL2) Lidar 'collections' with a resolution (RESCLASS) of 0.7m. For an overview of...

  11. Roentgenological differential diagnosis of the psoas contour

    International Nuclear Information System (INIS)

    Voran, G.; Pfab, R.; Hess, F.

    1984-01-01

    The assessment of the psoas border contour in the X-ray photo of the abdomen is important for differential diagnostic considerations. For the separation of fallacious psoas configurations which are similar to the well defined pathological form changes, a regular supine position of the patient was chosen, and the psoas examined without and with muscle tension. The whole visible psoas muscle system did not show any unilateral bulging of the border silhouette during muscle action. Isolated tension of the left psoas muscle induced a distinct deviation of both border contours to the left side, too. There was a clear tendency of a more distinct psoas border contour and of augmented opacity of the muscle over its whole length under muscle tension. Changes similar to the bulging border contour of a psoas abscess were not produced by muscular action. (orig.) [de

  12. A cardiac contouring atlas for radiotherapy

    DEFF Research Database (Denmark)

    Duane, Frances; Aznar, Marianne C; Bartlett, Freddie

    2017-01-01

    defined from cardiology models and agreed by two cardiologists. Reference atlas contours were delineated and written guidelines prepared. Six radiation oncologists tested the atlas. Spatial variation was assessed using the DICE similarity coefficient (DSC) and the directed Hausdorff average distance (d→H,avg......-observer contour separation (mean d→H,avg) was 1.5-2.2mm for left ventricular segments and 1.3-5.1mm for coronary artery segments. This spatial variation resulted in

  13. Variation in contour and cancer of stomach

    International Nuclear Information System (INIS)

    Lee, Won Hong; Hwang, Seon Moon; Yoon, Kwon Ha

    1999-01-01

    There were four types of stomach contour included eutonic, hypotonic, steerhorn, and cascade. The aim of this study is to clarify relationship between incidence of stomach cancer and contour variation of the stomach. Double- contrast upper gastrointestinal study was performed in 1,546 patients, who had dyspepsia or other gastrointestinal tract symptoms. The radiographs were classified into the four types including eutonic, hypotonic, steerhorn, and cascade according to stomach contour in relation to body build. We also reviewed pathologic reports on endoscopic biopsy or surgical specimen. We studied the presence of relationship between incidence of stomach cancer and variation of stomach contour. We also examined the incidence of gastritis and gastric ulcer to the stomach contour variation. Of total 1,546 patients, eutonic stomach were 438(28.3%), hypotonic 911(58.9%), steerhorn 102(6.5%) and cascade 95(6.2%). Stomach cancer was found in 139(31.7%) of 438 eutonic stomachs, in 135(14.8%) of 911 hypotonic, in 42(41.2%) of 102 steerhorn, and in 24(36.9%) of 95 cascade (P=0.001). In hypotonic stomach, the incidence of stomach cancer was lower compared to the other three types significantly (p<0.05). Gastritis or gastric ulcer was found in 146(33.3%) of eutonic stomach, in 293(32.1%) of hypotonic, in 36(35.2%) of steerhorn, and in 26(27.3%) of cascade (p=0.640). In conclusion, gastric contour variation seems to be a factor affecting development of stomach cancer. The patients with hypotonic stomach may have lower incidence of stomach cancer than that of the other types. There was no relationship between the contour and gastric ulcer

  14. Variation in contour and cancer of stomach

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Hong; Hwang, Seon Moon [Asan Medical Center, Asan (Korea, Republic of); Yoon, Kwon Ha [College of Medicine, Wonkwang Univ., Iksan (Korea, Republic of)

    1999-04-01

    There were four types of stomach contour included eutonic, hypotonic, steerhorn, and cascade. The aim of this study is to clarify relationship between incidence of stomach cancer and contour variation of the stomach. Double- contrast upper gastrointestinal study was performed in 1,546 patients, who had dyspepsia or other gastrointestinal tract symptoms. The radiographs were classified into the four types including eutonic, hypotonic, steerhorn, and cascade according to stomach contour in relation to body build. We also reviewed pathologic reports on endoscopic biopsy or surgical specimen. We studied the presence of relationship between incidence of stomach cancer and variation of stomach contour. We also examined the incidence of gastritis and gastric ulcer to the stomach contour variation. Of total 1,546 patients, eutonic stomach were 438(28.3%), hypotonic 911(58.9%), steerhorn 102(6.5%) and cascade 95(6.2%). Stomach cancer was found in 139(31.7%) of 438 eutonic stomachs, in 135(14.8%) of 911 hypotonic, in 42(41.2%) of 102 steerhorn, and in 24(36.9%) of 95 cascade (P=0.001). In hypotonic stomach, the incidence of stomach cancer was lower compared to the other three types significantly (p<0.05). Gastritis or gastric ulcer was found in 146(33.3%) of eutonic stomach, in 293(32.1%) of hypotonic, in 36(35.2%) of steerhorn, and in 26(27.3%) of cascade (p=0.640). In conclusion, gastric contour variation seems to be a factor affecting development of stomach cancer. The patients with hypotonic stomach may have lower incidence of stomach cancer than that of the other types. There was no relationship between the contour and gastric ulcer.

  15. A cognitive evaluation procedure for contour based shape descriptors

    NARCIS (Netherlands)

    Ghosh, Anarta; Petkov, Nicolai

    2005-01-01

    Present image processing algorithms are unable to extract a neat and closed contour of an object of interest from a natural image. Advanced contour detection algorithms extract the contour of an object of interest from a natural scene with a side effect of depletion of the contour. Hence in order to

  16. The foot and ankle

    International Nuclear Information System (INIS)

    Berquist, T.H.

    1985-01-01

    Imaging of the foot and ankle can be difficult because of the complex anatomy. Familiarity with the bony and ligamentous anatomy is essential for proper evaluation of radiographic findings. Therefore, pertinent anatomy is discussed as it applies to specific injuries. Special views, tomography, arthrography, and other techniques may be indicated for complete evaluation of foot and ankle trauma

  17. Prostate Contouring Variation: Can It Be Fixed?

    International Nuclear Information System (INIS)

    Khoo, Eric L.H.; Schick, Karlissa; Plank, Ashley W.; Poulsen, Michael; Wong, Winnie W.G.; Middleton, Mark; Martin, Jarad M.

    2012-01-01

    Purpose: To assess whether an education program on CT and MRI prostate anatomy would reduce inter- and intraobserver prostate contouring variation among experienced radiation oncologists. Methods and Materials: Three patient CT and MRI datasets were selected. Five radiation oncologists contoured the prostate for each patient on CT first, then MRI, and again between 2 and 4 weeks later. Three education sessions were then conducted. The same contouring process was then repeated with the same datasets and oncologists. The observer variation was assessed according to changes in the ratio of the encompassing volume to intersecting volume (volume ratio [VR]), across sets of target volumes. Results: For interobserver variation, there was a 15% reduction in mean VR with CT, from 2.74 to 2.33, and a 40% reduction in mean VR with MRI, from 2.38 to 1.41 after education. A similar trend was found for intraobserver variation, with a mean VR reduction for CT and MRI of 9% (from 1.51 to 1.38) and 16% (from 1.37 to 1.15), respectively. Conclusion: A well-structured education program has reduced both inter- and intraobserver prostate contouring variations. The impact was greater on MRI than on CT. With the ongoing incorporation of new technologies into routine practice, education programs for target contouring should be incorporated as part of the continuing medical education of radiation oncologists.

  18. Development of a CONTOUR-METER

    International Nuclear Information System (INIS)

    Andrada Contardi, F.A.

    2004-01-01

    Dose calculation in patients undergoing radiotherapy treatments requires the knowledge of their anatomical geometry.Making reference to the specific case of breast cancer, one of the measurement that are made on the patients is the acquisition of the breast's contour, determined in an axial plane from a point marked on the breastbone until another point marked on the thorax side under the armpit.This measurement is normally made with a mechanic contour-meter: a device formed by a series of plastic-covered wires designed to be applied on the patient's skin copying the breast contour after it deformation.The geometrical error associated with this procedure is ± 1 cm. The precision of the dose calculation could be increased acquiring a breast contour more accurate.This objective was achieved developing a method based on breast images from a digital camera.The algorithms to obtain an axial-plane image of the contour from digital photographs taken from arbitrary positions were developed.A geometric transformation is applied to the photograph to correct for perspective distortions, obtaining a frontal - undistorted image (axial-plane image).A software tool to make all the image processing was developed under MatLab.The maximum geometrical error detected during the validation of the process was 2 mm [es

  19. Foot Function, Foot Pain, and Falls in Older Adults: The Framingham Foot Study.

    Science.gov (United States)

    Awale, Arunima; Hagedorn, Thomas J; Dufour, Alyssa B; Menz, Hylton B; Casey, Virginia A; Hannan, Marian T

    2017-01-01

    Although foot pain has been linked to fall risk, contributions of pain severity, foot posture, or foot function are unclear. These factors were examined in a cohort of older adults. The purpose of this study was to examine the associations of foot pain, severity of foot pain, and measures of foot posture and dynamic foot function with reported falls in a large, well-described cohort of older adults from the Framingham Foot Study. Foot pain, posture, and function were collected from Framingham Foot Study participants who were queried about falls over the past year (0, 1, and ≥2 falls). Logistic regression was used to calculate odds ratios (ORs) and 95% confidence intervals (CIs) for the relation of falls with foot pain, pain severity, foot posture, and foot function adjusting for covariates. The mean age of the 1,375 participants was 69 years; 57% were female, and 21% reported foot pain (40% mild pain, 47% moderate pain, and 13% severe pain). One-third reported falls in the past year (1 fall: n = 263, ≥2 falls: n = 152). Foot pain was associated with a 62% increased odds of recurrent falls. Those with moderate and severe foot pain showed increased odds of ≥2 falls (OR 1.78, CI 1.06-2.99, and OR 3.25, CI 1.65-7.48, respectively) compared to those with no foot pain. Foot function was not associated with falls. Compared to normal foot posture, those with planus foot posture had 78% higher odds of ≥2 falls. Higher odds of recurrent falls were observed in individuals with foot pain, especially severe foot pain, as well as in individuals with planus foot posture, indicating that both foot pain and foot posture may play a role in increasing the risk of falls among older adults. © 2017 S. Karger AG, Basel.

  20. The psychological impact of body contouring surgery

    DEFF Research Database (Denmark)

    Mikkelsen Lorenzen, Mike; Poulsen, Lotte; Poulsen, Signe

    2018-01-01

    INTRODUCTION: Body contouring surgery is associated with changes in body image and identity. The primary aim of the study was to investigate a multidisciplinary assessment of potential psychological challenges before and after body contouring surgery. METHODS: Eight pre- and post-operative patients...... relevant codes had been extracted. RESULTS: A total of seven psychological themes were iden- tified, indicating that surgery alone cannot improve the pa- tients’ psychological difficulties and that psychological care and management of the expected discomfort and body im- age is of considerable importance...... in providing continuity of care. CONCLUSIONS: The reported quality of life is of consider- able importance to patients undergoing body contouring surgery after massive weight loss. Our findings may provide useful information for surgeons and healthcare profes- sionals allowing them to develop patient education...

  1. A comparative study on strengthening applications of prefabricated buildings in earthquake regions

    International Nuclear Information System (INIS)

    Arslan, M. Hakan; Gulay, F. Gulten

    2006-01-01

    Damages to prefabricated industrial structures caused by earthquakes in the last ten years in Turkey have occurred to an enormous extent. Among the causes of this damage, the inherent characteristic weakness of the load-carrying systems and constructing most of them according to the earthquake code applied before 1998 can be listed. The tragic situation that appeared after earthquakes emphasized that existing prefabricated constructions should be strengthened/improved according to the code which became valid after 1998. This study comprises three sections. The damage types in prefabricated reinforced concrete structures caused by earthquakes and the strengthening models (samples) that can be applied to these structures will be mentioned in the first and second sections, respectively. The last and the analytical part of the study will be about the selection of the most often damaged industrial construction type which is preferred in industrial regions and application of selecting strengthening methods performed by modeling these structures according to three different span types (1-S, 2-S, 3-S). The strengthening methods will be Sheer wall (SW), Steel Bracing (B), Steel Beam (SB) and Column Jacketing (CJ). All the systems will be calculated by using non-linear procedures (pushover analysis). The analysis performed by using a Software Package (DRAIN-2DX), will be applied to each frame in order to obtain load-displacement curves. The real hinge parameters will be defined using FEMA-356 to reflect the existing conditions. The results will be compared by considering the contribution of strengthening and especially system performance to displacement ductility. (author)

  2. Facial contour deformity correction with microvascular flaps based on the 3-dimentional template and facial moulage

    Directory of Open Access Journals (Sweden)

    Dinesh Kadam

    2013-01-01

    Full Text Available Introduction: Facial contour deformities presents with varied aetiology and degrees severity. Accurate assessment, selecting a suitable tissue and sculpturing it to fill the defect is challenging and largely subjective. Objective assessment with imaging and software is not always feasible and preparing a template is complicated. A three-dimensional (3D wax template pre-fabricated over the facial moulage aids surgeons to fulfil these tasks. Severe deformities demand a stable vascular tissue for an acceptable outcome. Materials and Methods: We present review of eight consecutive patients who underwent augmentation of facial contour defects with free flaps between June 2005 and January 2011. De-epithelialised free anterolateral thigh (ALT flap in three, radial artery forearm flap and fibula osteocutaneous flap in two each and groin flap was used in one patient. A 3D wax template was fabricated by augmenting the deformity on facial moulage. It was utilised to select the flap, to determine the exact dimensions and to sculpture intraoperatively. Ancillary procedures such as genioplasty, rhinoplasty and coloboma correction were performed. Results: The average age at the presentation was 25 years and average disease free interval was 5.5 years and all flaps survived. Mean follow-up period was 21.75 months. The correction was aesthetically acceptable and was maintained without any recurrence or atrophy. Conclusion: The 3D wax template on facial moulage is simple, inexpensive and precise objective tool. It provides accurate guide for the planning and execution of the flap reconstruction. The selection of the flap is based on the type and extent of the defect. Superiority of vascularised free tissue is well-known and the ALT flap offers a versatile option for correcting varying degrees of the deformities. Ancillary procedures improve the overall aesthetic outcomes and minor flap touch-up procedures are generally required.

  3. Effect of surface treatment of prefabricated teeth on shear bond strength of orthodontic brackets

    OpenAIRE

    Cumerlato, Marina; Lima, Eduardo Martinelli de; Osorio, Leandro Berni; Mota, Eduardo Gonçalves; Menezes, Luciane Macedo de; Rizzatto, Susana Maria Deon

    2017-01-01

    ABSTRACT Objective: The aim of this in vitro study was to evaluate and compare the effects of grinding, drilling, sandblasting, and ageing prefabricated teeth (PfT) on the shear bond strength (SBS) of orthodontic brackets, as well as the effects of surface treatments on the adhesive remnant index (ARI). Methods: One-hundred-ninety-two PfT were divided into four groups (n = 48): Group 1, no surface treatment was done; Group 2, grinding was performed with a cylindrical diamond bur; Group 3,...

  4. Effect of surface treatment of prefabricated posts on bonding of resin cement

    DEFF Research Database (Denmark)

    Sahafi, Alireza; Peutzfeld, Anne; Asmussen, Erik

    2004-01-01

    This in vitro study evaluated the effect of various surface treatments of prefabricated posts of titanium alloy (ParaPost XH), glass fiber (ParaPost Fiber White) and zirconia (Cerapost) on the bonding of two resin cements: ParaPost Cement and Panavia F by a diametral tensile strength (DTS) test...... the start of mixing the resin cement, the specimen was freed from the mold and stored in water at 37 degrees C for seven days. Following water storage, the specimen was wet-ground to a final length of approximately 3 mm. The DTS of specimens was determined in a Universal Testing Machine. The bonding...

  5. In-Plane Strengthening Effect of Prefabricated Concrete Walls on Masonry Structures: Shaking Table Test

    Directory of Open Access Journals (Sweden)

    Weiwei Li

    2017-01-01

    Full Text Available The improvement effect of a new strengthening strategy on dynamic action of masonry structure, by installing prefabricated concrete walls on the outer facades, is validated by shaking table test presented in this paper. We carried out dynamic tests of two geometrically identical five-story reduced scaled models, including an unstrengthened and a strengthened masonry model. The experimental analysis encompasses seismic performances such as cracking patterns, failure mechanisms, amplification factors of acceleration, and displacements. The results show that the strengthened masonry structure shows much more excellent seismic capacity when compared with the unstrengthened one.

  6. Custom-made prefabricated titanium miniplates in Le Fort I osteotomies: principles, procedure and clinical insights.

    Science.gov (United States)

    Philippe, B

    2013-08-01

    This paper describes a new type of miniplate system that is designed and custom made during virtual surgery planning based on an individual patient's osteotomy. These miniplates are prefabricated with commercially pure porous titanium using direct metal laser sintering. The principles that guide the conception and production of this new miniplate are presented. The surgical procedure from the stage of virtual surgery planning until the final Le Fort I osteotomy and bone fixation are described using a case example. Copyright © 2013 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  7. Automatic Construction by Contour Crafting Technology

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Khorramshahi

    2017-07-01

    Full Text Available Contour Crafting is a novel technology in construction industry based on 3D printing that uses robotics to construct free form building structures by repeatedly laying down layers of material such as concrete. It is actually an approach to scale up automatic fabrication from building small industrial parts to constructing buildings. However, there are little information about contour crafting (CC in current use; present paper aims to describe the operational steps of creating a whole building by the machine reviewing relevant literature. Furthermore, it will represent the advantages of CC usage compared to traditional construction methods, as well as its applicability in construction industry.

  8. Deformation of contour and Hawking temperature

    International Nuclear Information System (INIS)

    Ding Chikun; Jing Jiliang

    2010-01-01

    It was found that, in an isotropic coordinate system, the tunneling approach brings a factor of 1/2 for the Hawking temperature of a Schwarzschild black hole. In this paper, we address this kind of problem by studying the relation between the Hawking temperature and the deformation of the integral contour for the scalar and Dirac particles tunneling. We find that the correct Hawking temperature can be obtained exactly as long as the integral contour deformed corresponding to the radial coordinate transform if the transformation is a non-regular or zero function at the event horizon.

  9. Foot morphology of Turkish football players according to foot ...

    African Journals Online (AJOL)

    Football is the most popular sport in the world. Foot morphology and foot preference are important factors in football player's performance. The aim of this cross-sectional study was to evaluate the foot morphology of elite football players with different foot preferences. 407 male football players participated in this study. 328 of ...

  10. Prefabricated EPS Elements used as Strip Foundation of a Single-family House with a Double Brick Wall

    OpenAIRE

    Rasmussen, Torben Valdbjørn

    2008-01-01

    A new prefabricated lightweight element was designed for a strip foundation that was demonstrated on site as the base of a single-family house with a double brick wall. The element was placed on a stable surface underneath the top soil layer, just 0.25 m underneath the finished ground surface. The prefabricated element was designed to fulfil the requirements of low energy consumption required by the new Danish Building Regulations. The base of the house was cast in one working operation and c...

  11. Prefabricated EPS Elements used as Strip Foundation of a Single-family House with a Double Brick Wall

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2008-01-01

    A new prefabricated lightweight element was designed for a strip foundation that was demonstrated on site as the base of a single-family house with a double brick wall. The element was placed on a stable surface underneath the top soil layer, just 0.25 m underneath the finished ground surface....... The prefabricated element was designed to fulfil the requirements of low energy consumption required by the new Danish Building Regulations. The base of the house was cast in one working operation and completed within two working days. The element, made of expanded polystyrene, was designed to be handled on site...

  12. Maintaining Contour Trees of Dynamic Terrains

    DEFF Research Database (Denmark)

    Agarwal, Pankaj K.; Mølhave, Thomas; Revsbæk, Morten

    2015-01-01

    We study the problem of maintaining the contour tree T of a terrain Sigma, represented as a triangulated xy-monotone surface, as the heights of its vertices vary continuously with time. We characterize the combinatorial changes in T and how they relate to topological changes in Sigma. We present ...

  13. Maintaining Contour Trees of Dynamic Terrains

    DEFF Research Database (Denmark)

    Agarwal, Pankaj K.; Arge, Lars; Mølhave, Thomas

    We consider maintaining the contour tree T of a piecewise-linear triangulation M that is the graph of a time varying height function h:R2→R. We carefully describe the combinatorial change in T that happen as h varies over time and how these changes relate to topological changes in M. We present a...

  14. A new method of prefabricated vascularized allogenic bone grafts for maxillo-mandibular reconstruction

    International Nuclear Information System (INIS)

    Pill-Hoon Choung

    1999-01-01

    Although there are various applications of allogenic bone grafts, a new technique of prevascularized lyophilized allogenic bone grafting for maxillo-mandibular reconstruction will be presented. Allogenic bone has been made by author's protocol for jaw defects as a powder, chip or block bone type. The author used lyophilized allogenic bone grafts for discontinuity defects as a block bone. In those cases, neovascularization and resorption of the allogenic bone were important factors for success of grafting. To overcome the problems, the author designed the technique of prefabricated vascularization of allogenic bone, which was lyophilized cranium, with an application of bovine BMP or not. Lyophilized cranial bone was designed for the defects and was put into the scalp. After confirming a hot spot via scintigram several months later, vascularized allogenic bone was harvested pedicled on the parietotemporal fascia based on the superficial temporal artery and vein. Vascularized allogenic cranial bone was rotated into the defect and fixed rigidly. Postoperatively, there was no severe resorption and functional disturbance of the mandible. In this technique, BMP seems to be an important role to help osteogenesis and neovascularization. Eight patients underwent prefabricated vascularization of allogenic bone grafts. Among them, four cases of reconstruction in mandibular discontinuity defects and one case of reconstruction in maxillectomy defect underwent this method, which will be presented with good results. This method may be an alternative technique of microvascular free bone graft

  15. Axial Compression Behavior of a New Type of Prefabricated Concrete Sandwich Wall Panel

    Science.gov (United States)

    Qun, Xie; Shuai, Wang; Chun, Liu

    2018-03-01

    A novel type of prefabricated concrete sandwich wall panel which could be used as a load-bearing structural element in buildings has been presented in this paper. Compared with the traditional sandwich panels, there are several typical characteristics for this wall system, including core columns confined by spiral stirrup along the cross-section of panel with 600mm spacing, precast foamed concrete block between two structural layers as internal insulation part, and a three-dimensional (3D) steel wire skeleton in each layer which is composed of two vertical steel wire meshes connected by horizontally short steel bar. All steel segments in the panel are automatically prefabricated in factory and then are assembled to form steel system in site. In order to investigate the structural behavior of this wall panel, two full-scale panels have been experimentally studied under axial compressive load. The test results show that the wall panel presents good load-bearing capacity and integral stiffness without out-of-plane flexural failure. Compared to the panel with planar steel wire mesh in concrete layer, the panel with 3D steel wire skeleton presents higher strength and better rigidity even in the condition of same steel ratio in panels which verifies that the 3D steel skeleton could greatly enhance the structural behavior of sandwich panel.

  16. Prefabrication of axial vascularized tissue engineering coral bone by an arteriovenous loop: A better model

    International Nuclear Information System (INIS)

    Dong Qingshan; Shang Hongtao; Wu Wei; Chen Fulin; Zhang Junrui; Guo Jiaping; Mao Tianqiu

    2012-01-01

    The most important problem for the survival of thick 3-dimensional tissues is the lack of vascularization in the context of bone tissue engineering. In this study, a modified arteriovenous loop (AVL) was developed to prefabricate an axial vascularized tissue engineering coral bone in rabbit, with comparison of the arteriovenous bundle (AVB) model. An arteriovenous fistula between rabbit femoral artery and vein was anastomosed to form an AVL. It was placed in a circular side groove of the coral block. The complex was wrapped with an expanded-polytetrafluoroethylene membrane and implanted beneath inguinal skin. After 2, 4, 6 and 8 weeks, the degree of vascularization was evaluated by India ink perfusion, histological examination, vascular casts, and scanning electron microscopy images of vascular endangium. Newly formed fibrous tissues and vasculature extended over the surfaces and invaded the interspaces of entire coral block. The new blood vessels robustly sprouted from the AVL. Those invaginated cavities in the vascular endangium from scanning electron microscopy indicated vessel's sprouted pores. Above indexes in AVL model are all superior to that in AVB model, indicating that the modified AVL model could more effectively develop vascularization in larger tissue engineering bone. - Highlights: ► A modified arteriovenous loop (AVL) model in rabbit was developed in this study. ► Axial prevascularization was induced in a larger coral block by using the AVL. ► The prefabrication of axial vascularized coral bone is superior as vascular carrier.

  17. The diabetic foot

    OpenAIRE

    Nabuurs-Franssen, M.H.

    2005-01-01

    The diabetic foot presents a complex interplay of neuropathic, macrovascular, and microvascular disease on an abnormal metabolic background, complicated by an increased susceptibility to mechanical, thermal, and chemical injury and decreased healing ability. The abnormalities of diabetes, once present, are not curable. But most severe foot abnormalities in the diabetic are due to neglect of injury and are mostly preventable. The physician must ensure that the diabetic patient learns the princ...

  18. Athlete's Foot: Clinical Update.

    Science.gov (United States)

    Ramsey, M L

    1989-10-01

    In brief: Athletes are particularly prone to athlete's foot because they are generally more exposed than others to conditions that encourage fungal growth, eg, communal showers and locker rooms. Diagnosis of athlete's foot rests on clinical suspicion and laboratory testing. Treatment may consist of topical antifungal agents and, for more resistant cases, oral griseofulvin. Preventive measures include keeping the feet dry, wearing nonocclusive leather shoes or sandals and absorbent cotton socks, and applying talcum or antifungal powder at least twice daily.

  19. [Minor foot amputations in diabetic foot syndrome].

    Science.gov (United States)

    Biehl, C; Eckhard, M; Szalay, G; Heiss, C

    2016-10-01

    The treatment strategy for diabetic foot syndrome must take into account protective sensibility of the foot, open wounds, infection status, and the rules of septic bone surgery. Interventions are classified as elective, prophylactic, curative, or emergency. Amputations in the forefoot and midfoot region are performed as ray amputations (including metatarsal), which can often be carried out as "inner" amputations. Gentle tissue treatment mandatory because of greater risk of revision with re-amputation compared to classical amputation. Good demarcation of infection, acute osteomyelitis, osteolytic lesions, neurotropic ulcer, arterial and venous blood flow to the other toes, gangrene of other toes with metatarsal affection. Arterial occlusive disease, infection of neighboring areas, avoidable amputations, poorly healing ulcers on the lower leg. Primary dorsal approach; minimal incisional distance (5 cm) to minimize skin necrosis risk. Atraumatic preparation, minimize hemostasis to not compromise the borderline perfusion situation. In amputations, plantar skin preparation and longer seams placed as dorsal as possible, either disarticulated and maintain cartilage, or round the cortical metatarsal bone after resection. Diabetes control. Braun splint, mobilization in a shoe with forefoot decompression and hindfoot support, physiotherapy. Antibiotics based on resistance testing. If no complications, dressing change on postoperative day 1. Optimal wound drainage by lowering foot several times a day; drainage removal after 12-24 h. Insoles and footwear optimization. Amputations require continued attention and if necessary treatment to avoid sequelae. Insufficient treatment associated with recurrent ulceration and altered anatomy.

  20. Education for diabetic foot

    Directory of Open Access Journals (Sweden)

    Fabio Batista

    2009-03-01

    Full Text Available Objective: The purpose of this investigation was to stratify the risk in a consecutive group of diabetic patients presenting, for the first time, in a diabetic foot clinic. Additional aims were to investigate the preventive measures in the local health system and to evaluate the level of patient’s awareness about diabetic foot-associated morbidity. Methods: Fifty consecutive adult diabetic patients referred to a Diabetic Foot Clinic of a Municipal Public Hospital comprised the sample for this observational study. The enrollment visit was considered as the first health-system intervention for potential foot morbidity. The average time elapsed since a diagnosis of diabetes among patients was five years. Rresults: At the time of presentation, 94% of sample was not using appropriate footwear. Pedal pulses (dorsalis pedis and/or posterior tibial arteries were palpable in 76% of patients. Thirty subjects (60% had signs of peripheral neuropathy. Twenty-one subjects (42% had clinical deformity. There was a positive correlation between a history of foot ulcer, the presence of peripheral neuropathy, and the presence of foot deformity (p < 0.004 in each correlation. Cconclusions: Informing and educating the patients and those interested in this subject and these problems is essential for favorable outcomes in this scenario.

  1. Subsidence Contours for South Louisiana; UTM 15N NAD83; LRA (2005); [subsidence_contours

    Data.gov (United States)

    Louisiana Geographic Information Center — The GIS data shapefile represents average subsidence contour intervals (0.02 cm/year over 10,000 years) for Coastal LA derived from the following: Kulp, M.A., 2000,...

  2. Anatomical contouring variability in thoracic organs at risk

    Energy Technology Data Exchange (ETDEWEB)

    McCall, Ross, E-mail: rmccall86@gmail.com [Medical Dosimetry Program, University of Wisconsin, La Crosse, WI (United States); MacLennan, Grayden; Taylor, Matthew; Lenards, Nishele [Medical Dosimetry Program, University of Wisconsin, La Crosse, WI (United States); Nelms, Benjamin E. [Canis Lupus LLC, Madison, WI (United States); Koshy, Matthew; Lemons, Jeffrey [Department of Radiation and Cellular Oncology, University of Chicago, Chicago, IL (United States); Hunzeker, Ashley [Medical Dosimetry Program, University of Wisconsin, La Crosse, WI (United States)

    2016-01-01

    The purpose of this study was to determine whether contouring thoracic organs at risk was consistent among medical dosimetrists and to identify how trends in dosimetrist's education and experience affected contouring accuracy. Qualitative and quantitative methods were used to contextualize the raw data that were obtained. A total of 3 different computed tomography (CT) data sets were provided to medical dosimetrists (N = 13) across 5 different institutions. The medical dosimetrists were directed to contour the lungs, heart, spinal cord, and esophagus. The medical dosimetrists were instructed to contour in line with their institutional standards and were allowed to use any contouring tool or technique that they would traditionally use. The contours from each medical dosimetrist were evaluated against “gold standard” contours drawn and validated by 2 radiation oncology physicians. The dosimetrist-derived contours were evaluated against the gold standard using both a Dice coefficient method and a penalty-based metric scoring system. A short survey was also completed by each medical dosimetrist to evaluate their individual contouring experience. There was no significant variation in the contouring consistency of the lungs and spinal cord. Intradosimetrist contouring was consistent for those who contoured the esophagus and heart correctly; however, medical dosimetrists with a poor metric score showed erratic and inconsistent methods of contouring.

  3. Modelling foot height and foot shape-related dimensions.

    Science.gov (United States)

    Xiong, Shuping; Goonetilleke, Ravindra S; Witana, Channa P; Lee Au, Emily Yim

    2008-08-01

    The application of foot anthropometry to design good-fitting footwear has been difficult due to the lack of generalised models. This study seeks to model foot dimensions so that the characteristic shapes of feet, especially in the midfoot region, can be understood. Fifty Hong Kong Chinese adults (26 males and 24 females) participated in this study. Their foot lengths, foot widths, ball girths and foot heights were measured and then evaluated using mathematical models. The results showed that there were no significant allometry (p > 0.05) effects of foot length on ball girth and foot width. Foot height showed no direct relationship with foot length. However, a normalisation with respect to foot length and foot height resulted in a significant relationship for both males and females with R(2) greater than 0.97. Due to the lack of a direct relationship between foot height and foot length, the current practice of grading shoes with a constant increase in height or proportionate scaling in response to foot length is less than ideal. The results when validated with other populations can be a significant way forward in the design of footwear that has an improved fit in the height dimension.

  4. USGS Elevation Contours Overlay Map Service from The National Map

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The USGS Elevation Contours service from The National Map (TNM) consists of contours generated for the conterminous United States from 1- and 1/3 arc-second...

  5. Power, heat and cooling by intelligent prefabricated components from concretes; Strom, Waerme und Kuehlung mit intelligenten Fertigteilen aus Beton

    Energy Technology Data Exchange (ETDEWEB)

    Riffel, Siegfried [HeidelbergCement AG, Talheim (Germany). Entwicklung und Anwendung

    2006-10-15

    Starting of present ecological and economical requirements to buildings renewable energy sources like photovoltaics and solar power will play an important role in future as also change construction engineering and architecture of city design till into detail. The existing contribution presents an innovative result for a massive roof- and wall system from prefabricated concrete components with integrated solar collectors and PV modules. (GL)

  6. Heat Storage Performance of the Prefabricated Hollow Core Concrete Deck Element with Integrated Microencapsulated Phase Change Material

    DEFF Research Database (Denmark)

    Pomianowski, Michal Zbigniew; Heiselberg, Per; Jensen, Rasmus Lund

    2012-01-01

    The paper presents the numerically calculated dynamic heat storage capacity of the prefabricated hollow core concrete deck element with and without microencapsulated phase change material (PCM). The reference deck is the ordinary deck made of standard concrete material and that is broadly used...

  7. Invariance Signatures: Characterizing contours by their departures from invariance

    OpenAIRE

    Squire, David; Caelli, Terry M.

    1997-01-01

    In this paper, a new invariant feature of two-dimensional contours is reported: the Invariance Signature. The Invariance Signature is a measure of the degree to which a contour is invariant under a variety of transformations, derived from the theory of Lie transformation groups. It is shown that the Invariance Signature is itself invariant under shift, rotation and scaling of the contour. Since it is derived from local properties of the contour, it is well-suited to a neural network implement...

  8. Sound wave contours around wind turbine arrays

    International Nuclear Information System (INIS)

    Van Beek, A.; Van Blokland, G.J.

    1993-02-01

    Noise pollution is an important factor in selecting suitable sites for wind turbines in order to realize 1000 MW of wind power as planned by the Dutch government for the year 2000. Therefore an accurate assessment of wind turbine noise is important. The amount of noise pollution from a wind turbine depends on the wind conditions. An existing standard method to assess wind turbine noise is supplemented and adjusted. In the first part of the investigation the method was developed and applied for a solitary sound source. In the second part attention is paid to the use of the method for wind turbine arrays. It appears that the adjusted method results in a shift of the contours of the permitted noise level. In general the contours are 15-25% closer to the wind farm, which means that the minimal permitted distance between houses and wind turbine arrays can be reduced. 14 figs., 1 tab., 4 appendices, 7 refs

  9. Contour forming of metals by laser peening

    Science.gov (United States)

    Hackel, Lloyd; Harris, Fritz

    2002-01-01

    A method and apparatus are provided for forming shapes and contours in metal sections by generating laser induced compressive stress on the surface of the metal workpiece. The laser process can generate deep compressive stresses to shape even thick components without inducing unwanted tensile stress at the metal surface. The precision of the laser-induced stress enables exact prediction and subsequent contouring of parts. A light beam of 10 to 100 J/pulse is imaged to create an energy fluence of 60 to 200 J/cm.sup.2 on an absorptive layer applied over a metal surface. A tamping layer of water is flowed over the absorptive layer. The absorption of laser light causes a plasma to form and consequently creates a shock wave that induces a deep residual compressive stress into the metal. The metal responds to this residual stress by bending.

  10. A Market Equilibrium Supply Chain Model for Supporting Self-Manufacturing or Outsourcing Decisions in Prefabricated Construction

    Directory of Open Access Journals (Sweden)

    Yanhu Han

    2017-11-01

    Full Text Available Prefabricated construction is a sustainable alternative to traditional on-site construction methods. However, many challenges still exist in the prefabricated construction process. For example, self-manufacturing or outsourcing decisions are vital to the industrial structure and organization of the prefabricated construction industry, and the company’s production and operation decision-making. This paper considers a prefabricated construction supply chain, which is composed of one upstream component manufacturing company and two downstream contractors. The large contractor can get the precast component through self-manufacturing or outsourcing, while the small and medium-sized enterprise (SME contractor can only buy components from the component manufacturer. A comprehensive game model (Cournot-Stackelberg model under different decisions, that is, component self-manufacturing or outsourcing, was established. By solving the profit functions of different companies in the prefabricated construction supply chain, the equilibrium solutions of output, price and profit can be achieved. These solutions of equilibrium indicate the optimal decision on the production and operation, and the profit’s boundary conditions. After assuming relevant parameters, the profit levels of the companies in the supply chain are analyzed via a dynamic simulation in the changing process of prefabricated construction market size under different behavioral decisions. The conclusions are as follows: (1 the profit levels of all supply chain enterprises and the whole supply chain are increasing with an increase of market size; (2 the downstream contractors and the whole supply chain have a higher profit level under the component self-manufacturing decision, however, on the contrary, the upstream component suppliers get a higher profit level under the component outsourcing decision; (3 the equilibrium output of the SME contractor is reduced under the outsourcing decision of

  11. Perception of illusory contour figures: Microgenetic analysis

    OpenAIRE

    Gvozdenović Vasilije P.

    2004-01-01

    Microgenetic analysis was used to investigate perception of illusory contour figures which represent whole, completed forms on the basis of segmented, incomplete stimulation. The analysis provided an experimental approach to this phenomenon which was standardly investigated phenomenologically. Experimental procedure consisted of two phases: a) priming phase and b) test phase which consisted of visual search task. Two types of visual search tasks were applied: (i) classic detection, in which s...

  12. Making the cut for the contour method

    OpenAIRE

    Bouchard, P. John; Ledgard, Peter; Hiller, Stan; Hosseinzadh Torknezhad, Foroogh

    2012-01-01

    The contour method is becoming an increasingly popular measurement technique for mapping residual stress in engineering components. The accuracy of the technique is critically dependent on the quality of the cut performed. This paper presents results from blind cutting trials on austenitic stainless steel using electro-discharge machines made by three manufacturers. The suitability of the machines is assessed based on the surface finish achieved, risk of wire breakages and the nature of cutti...

  13. Edge and line oriented contour detection : State of the art

    NARCIS (Netherlands)

    Papari, Giuseppe; Petkov, Nicolai

    We present an overview of various edge and line oriented approaches to contour detection that have been proposed in the last two decades. By edge and line oriented we mean methods that do not rely on segmentation. Distinction is made between edges and contours. Contour detectors are divided in local

  14. Interactive 3D segmentation using connected orthogonal contours

    NARCIS (Netherlands)

    de Bruin, P. W.; Dercksen, V. J.; Post, F. H.; Vossepoel, A. M.; Streekstra, G. J.; Vos, F. M.

    2005-01-01

    This paper describes a new method for interactive segmentation that is based on cross-sectional design and 3D modelling. The method represents a 3D model by a set of connected contours that are planar and orthogonal. Planar contours overlayed on image data are easily manipulated and linked contours

  15. Incomplete contour representations and shape descriptors : ICR test studies

    NARCIS (Netherlands)

    Ghosh, Anarta; Petkov, Nicolai; Gregorio, MD; DiMaio,; Frucci, M; Musio, C

    2005-01-01

    Inspired by psychophysical studies of the human cognitive abilities we propose a novel aspect and a method for performance evaluation of contour based shape recognition algorithms regarding their robustness to incompleteness of contours. We use complete contour representations of objects as a

  16. Gait Recognition Based on Outermost Contour

    Directory of Open Access Journals (Sweden)

    Lili Liu

    2011-10-01

    Full Text Available Gait recognition aims to identify people by the way they walk. In this paper, a simple but e ective gait recognition method based on Outermost Contour is proposed. For each gait image sequence, an adaptive silhouette extraction algorithm is firstly used to segment the frames of the sequence and a series of postprocessing is applied to obtain the normalized silhouette images with less noise. Then a novel feature extraction method based on Outermost Contour is performed. Principal Component Analysis (PCA is adopted to reduce the dimensionality of the distance signals derived from the Outermost Contours of silhouette images. Then Multiple Discriminant Analysis (MDA is used to optimize the separability of gait features belonging to di erent classes. Nearest Neighbor (NN classifier and Nearest Neighbor classifier with respect to class Exemplars (ENN are used to classify the final feature vectors produced by MDA. In order to verify the e ectiveness and robustness of our feature extraction algorithm, we also use two other classifiers: Backpropagation Neural Network (BPNN and Support Vector Machine (SVM for recognition. Experimental results on a gait database of 100 people show that the accuracy of using MDA, BPNN and SVM can achieve 97.67%, 94.33% and 94.67%, respectively.

  17. Effectiveness of mesotherapy on body contouring.

    Science.gov (United States)

    Park, Seung Ha; Kim, Deok Woo; Lee, Min Ah; Yoo, Sang Chul; Rhee, Seung Chul; Koo, Sang Hwan; Seol, Geun Hye; Cho, Eun Young

    2008-04-01

    Despite the increasing interest in mesotherapy as an alternative method for body contouring, there are few reports of its safety, efficacy, and mechanism of action. A clinical examination was performed to evaluate the efficacy of mesotherapy for body contouring. Twenty women were enrolled in this prospective, case-controlled study over a 12-week period. The authors injected a mixed solution (i.e., aminophylline, buflomedil, and lidocaine) into the superficial dermis of the medial aspect of one thigh weekly using a mechanical delivery gun. There was no treatment to the other thigh. The change in the fat level was evaluated by measuring the girth of the thighs and by computed tomographic scanning. The lipid profiles were checked to determine the effect of mesotherapy on lipid metabolism, and questionnaires were used to determine the satisfaction rate of the patients. The loss of thigh girth on the treated side was not significantly different from that of the untreated side. The computed tomographic scans showed no statistically significant difference in the cross-sectional area or thickness of the fat layer between each group. There were no statistically significant changes in the lipid profiles except for the triglyceride level. A questionnaire asking about the effect of mesotherapy indicated poor patient satisfaction. Mesotherapy is not an effective alternative treatment modality for body contouring.

  18. Semi-automated contour recognition using DICOMautomaton

    International Nuclear Information System (INIS)

    Clark, H; Duzenli, C; Wu, J; Moiseenko, V; Lee, R; Gill, B; Thomas, S

    2014-01-01

    Purpose: A system has been developed which recognizes and classifies Digital Imaging and Communication in Medicine contour data with minimal human intervention. It allows researchers to overcome obstacles which tax analysis and mining systems, including inconsistent naming conventions and differences in data age or resolution. Methods: Lexicographic and geometric analysis is used for recognition. Well-known lexicographic methods implemented include Levenshtein-Damerau, bag-of-characters, Double Metaphone, Soundex, and (word and character)-N-grams. Geometrical implementations include 3D Fourier Descriptors, probability spheres, boolean overlap, simple feature comparison (e.g. eccentricity, volume) and rule-based techniques. Both analyses implement custom, domain-specific modules (e.g. emphasis differentiating left/right organ variants). Contour labels from 60 head and neck patients are used for cross-validation. Results: Mixed-lexicographical methods show an effective improvement in more than 10% of recognition attempts compared with a pure Levenshtein-Damerau approach when withholding 70% of the lexicon. Domain-specific and geometrical techniques further boost performance. Conclusions: DICOMautomaton allows users to recognize contours semi-automatically. As usage increases and the lexicon is filled with additional structures, performance improves, increasing the overall utility of the system.

  19. Imaging of Charcot foot

    International Nuclear Information System (INIS)

    Erlemann, Rainer; Schmitz, Annette

    2014-01-01

    The onset of a Charcot foot ist a feared complication of a long lasting diabetes mellitus. A peripheral neuropathy and continuous weight bearing of the foot subsequent to repeated traumas depict the conditions. There exist three types of a Charcot foot, an atrophic, a hypertophic and a mixed type. In early stages a differentiation from osteoarthritis is difficult. Subluxation or luxation within the Lisfranc's joint is typical. The joints of the foot could rapidly and extensively be destroyed or may present the morphology of a 'superosteoarthritis'. Often, soft tissue infections or osteomyelitis evolve from ulcers of the skin as entry points. Diagnosis of osteomyelitis necessitate MR imaging as plain radiography offers only low sensitivity for detection of an osteomyelitis. The existence of periosteal reactions is not a proof for osteomyelitis. Bone marrow edema and soft tissue edema also appear in a non infected Charcot foot. The range of soft tissue infections goes from cellulitis over phlegmon to abscesses. The ghost sign is the most suitable diagnostic criterion for osteomyelitis. In addition, the penumbra sign or the existence of a sinus tract between a skin ulcer and the affected bone may be helpful. (orig.)

  20. THE INFLUENCE OF A FOOT ORTHOTIC ON LOWER EXTREMITY TRANSVERSE PLANE KINEMATICS IN COLLEGIATE FEMALE ATHLETES WITH PES PLANUS

    Directory of Open Access Journals (Sweden)

    Christopher R. Carcia

    2006-12-01

    Full Text Available Non-contact anterior cruciate ligament (ACL injuries in female athletes remain prevalent. Athletes with excessive foot pronation have been identified to be at greater risk for non-contact ACL injury. Excessive foot pronation has been linked to increased medial tibial rotation. Increased medial tibial rotation heightens ACL strain and has been observed at or near the time of ACL injury. Foot orthotics have been shown to decrease medial tibial rotation during walking and running tasks. The effect of a foot orthotic on activities that simulate a non-contact ACL injury mechanism (i.e. landing however is unknown. Therefore, the objective of this study was to determine whether a foot orthotic was capable of altering transverse plane lower extremity kinematics in female athletes during landing. Twenty uninjured collegiate female athletes participating in the sports of basketball, soccer or volleyball with pes planus volunteered. Utilizing a repeated measures counterbalanced design, subjects completed two landing tasks with and without a foot orthotic using standardized footwear. The prefabricated orthotic had a rigid shell and a 6 extrinsic rear-foot varus post. Dependent measures included initial contact angle, peak angle, excursion and time to peak angle for both the tibia and femur. Statistical analysis suggested that the selected foot orthosis had little influence over lower extremity transverse plane kinematics. Several factors including: the limitation of a static measure to predict dynamic movement, inter-subject variability and the physical characteristics of the orthotic device likely account for the results. Future research should examine the influence of different types of foot orthotics not only on lower extremity kinematics but also tibiofemoral kinetics

  1. Improving Thermal Insulation Properties for Prefabricated Wall Components Made Of Lightweight Aggregate Concrete with Open Structure

    Science.gov (United States)

    Abramski, Marcin

    2017-10-01

    Porous concrete is commonly used in civil engineering due to its good thermal insulation properties in comparison with normal concrete and high compression strength in comparison with other building materials. Reducing of the concrete density can be obviously obtained by using lightweight aggregate (e.g. pumice). The concrete density can be further minimized by using specially graded coarse aggregate and little-to-no fine aggregates. In this way a large number of air voids arise. The aggregate particles are coated by a cement paste and bonded together with it just in contact points. Such an extremely porous concrete, called ‘lightweight aggregate concrete with open structure’ (LAC), is used in some German plants to produce prefabricated wall components. They are used mainly in hall buildings, e.g. supermarkets. The need of improving thermal insulation properties was an inspiration for the prefabrication plant managers, engineers and a scientific staff of the Technical University of Kaiserslautern / Germany to realise an interesting project. Its aim was to reduce the heat transfer coefficient for the wall components. Three different wall structure types were designed and compared in full-scale laboratory tests with originally produced wall components in terms of load-carrying capacity and stiffness. The load was applied perpendicularly to the wall plane. As the components are not originally used for load-bearing walls, but for curtain walls only, the wind load is the main load for them. The wall components were tested in horizontal position and the load was applied vertically. Totally twelve wall components 8.00 × 2.00 × 0.25m (three for every series) were produced in the prefabrication plant and tested in the University of Kaiserslautern laboratory. The designed and tested components differed from each other in the amount of expanded polystyrene (EPS), which was placed in the plant inside the wall structure. The minimal amount of it was designed in the

  2. Buildings of prefabricated concrete elements after 40-50 years of use

    Directory of Open Access Journals (Sweden)

    Milićević Milan

    2002-01-01

    Full Text Available After the Second World War in demolished Europe, existed an acute need for the accommodation of people without a shelter, what affected the builders to accelerate construction of serial temporary residential buildings. Later, are developed various systems of prefabricated multistory buildings of reinforced concrete. Such a new system of construction has given these advantages: shorter time of construction, lower expenditure, higher quality of buildings, more flexibility. However, after some time, the first expectation of the above possibilities started diminishing, especially when are revealed problems in their use and maintenance. The experience achieved in the Nord areas of Europe can be, in a greater extent, applicated in the South, especially where are strong rains, wind and high temperatures. Here are interpreted experiences from Finland.

  3. Transparent thermal insulation for prefabricated school buildings; Einsatz transparenter Waermedaemmung an Schulgebaeuden in praefabrizierter Bauweise

    Energy Technology Data Exchange (ETDEWEB)

    Russ, C. [Fraunhofer-Institut fuer Solare Energiesysteme (ISE), Freiburg im Breisgau (Germany). Gruppe Solares Bauen; Buchmann, R. [Leipzigprojekt GmbH, Leipzig (Germany); Duesterhoeft, A. [Holz- und Leichtmetallbau GmbH, Leipzig (Germany)

    1997-12-31

    The existing schools in the new federal states built from prefabricated elements need to be modernized in order to reduce their energy demand. Fitting some 300 square metres of transparent thermal insulation to the south side of a house front may lead to a cut in its thermal energy demand by 74 per cent. This energy consumption is by 12 kWh per square metre lower than the one obtained with opaque thermal insulation. The results of the first demonstration project are described. (MSK) [Deutsch] Die in den neuen Bundeslaendern vorhandenen Schulen in vorgefertigter Bauweise sind energetisch sanierungsbeduerftig. Werden im Rahmen einer Sanierung ca. 300qm transparente Waermedaemmung an der suedorientierten Fassade eingesetzt, so kann der Heizwaermebedarf um 74% herabgesetzt werden. Das sind 12 kWh/qm weniger als bei dem vergleichsweisen Einsatz einer opaken Waermedaemmung. Im Folgenden werden die Ergebnisse des ersten Demonstrationsprojekts beschrieben.

  4. Investigation on effectiveness of a prefabricated vertical drain during cyclic loading

    International Nuclear Information System (INIS)

    Indraratna, B; Ni, J; Rujikiatkamjorn, C

    2010-01-01

    The effectiveness of prefabricated vertical drains (PVDs) in enhancing the stability of soft soils during cyclic loading was investigated using triaxial cyclic loading tests. Both undrained and with PVD tests were employed to study the associated excess pore pressure and accumulated strain under the repeated loading condition. The loading frequency and cyclic stress ratio have been chosen to be the variables which influence the performance of soft clays. The experimental results illustrate that with PVDs, the excess pore water pressure generation during cyclic loading decreases significantly. It is found that the excess pore water pressure build up depends on both loading frequency and cyclic stress ratio. The excess pore water pressure will increase when each of them is increased. Furthermore, when the loading frequency is 0.1 Hz, the ratio of coefficient of consolidation under cyclic loading to that under static loading is almost one. With the increasing loading frequency, this ratio increases accordingly.

  5. Modern housing design: prefabricated and modular design in Frank Lloyd Wright's architecture

    Directory of Open Access Journals (Sweden)

    Ana Tagliari

    2011-12-01

    Full Text Available This paper investigates the residential architecture of Frank Lloyd Wright, especially the designs which were conceived from an idea of prefabricated, modular, low-cost, and high-scale construction. Wright's organic designs originated from a material-based grid, which at the same time organized and provided freedom to create spaces and forms. This study reviews Wright's work, from his first Midwest designs that relied on brick, through an intermediary phase in California when he made intense use of concrete blocks, until his last phase, the usonian houses, which featured wood paneling. During his early career, the concept and the methodology of Wright's ideas greatly contributed to a better understanding of his architecture, his apprentices and his followers. The economy and rationalization found in the projects reviewed are of great importance as the analysis of historical proposals helps us understand the topic in question.

  6. The Effect of Pre-teaching Extended Prefabricated Lexical Bundles on the Writing Development of

    Directory of Open Access Journals (Sweden)

    Seiyed Mahdi Araghi

    2014-03-01

    Full Text Available This study attempts to shed light on how a teacher’s instruction and guidance can cast aside writing inhibitions and bring about remarkable changes in the writing ability of advanced EFL students through the collaborative construction of extended chunks of language with the aim of enhancing lexical density and complexity and consequently injecting into learners a sense of satisfaction with their work. The sample included 40 TOEFL students selected out of 75 TOEFL students on the basis of their scores on a TOEFL test. The participants were randomly assigned into two groups-the control group and experimental group. After 20 instructional sessions both groups were assigned five writing tasks. The results reveal that the participants in experimental group outperformed their counterparts in control group. Overall, it is concluded that pre-teaching extended prefabricated lexical bundles can be a useful means of helping advanced students to improve their writing quality.

  7. Pathophysiology diabetic foot ulcer

    Science.gov (United States)

    Syafril, S.

    2018-03-01

    Diabetes Mellitus (DM) is known to have many complications. Diabetes and its complications are rapidly becoming the world’s most significant cause of morbidity and mortality, and one of the most distressing is Diabetic Foot Ulcer (DFU). Chronic wound complications are a growing concern worldwide, and the effect is a warning to public health and the economy. The etiology of a DFU is multifaceted, and several components cause added together create a sufficient impact on ulceration: neuropathy, vasculopathy, immunopathy, mechanical stress, and neuroarthropathy. There are many classifications of the diabetic foot. About 50% of patients with foot ulcers due to DM present clinical signs of infection. It is essential to manage multifactorial etiology of DFU to get a good outcome.

  8. Foot muscles strengthener

    Directory of Open Access Journals (Sweden)

    Boris T. Glavač

    2012-04-01

    Full Text Available Previous experience in the correction of flat feet consisted of the use of insoles for shoes and exercises with toys, balls, rollers, inclined planes, etc. A device for strengthening foot muscles is designed for the correction of flat feet in children and, as its name suggests, for strengthening foot muscles in adults. The device is made of wood and metal, with a mechanism and technical solutions, enabling the implementation of specific exercises to activate muscles responsible for the formation of the foot arch. It is suitable for home use with controlled load quantities since it has calibrated springs. The device is patented with the Intellectual Property Office, Republic of Serbia, as a petty patent.

  9. The structural study of prefabrication stress stent and the hemodynamics in percutaneous transhepatic portacaval shunt

    International Nuclear Information System (INIS)

    Chu Jianguo; Sun Xiaoli; Zhou Yijun; Huang He; Zhou Hua; Lv Chunyan; Yang Shuhui

    2006-01-01

    Objective: To present a preliminary latest procedure for portal hypertension and evaluate the technical feasibility and efficacy of portacaval shunt creation through the percutaneous transhepatic approach in order to make a hemodynamic comparison with that of the classic TIPS. Methods: Thirty-eight patients with portal hypertension (36 men; mean age 57 years, range 32-73) were referred for PTPS procedure because of bleeding varices (n=36), intractable ascites (n=1), and hepatopulmonary syndrome (n=1). The severity of liver disease was classified as Child-Pugh B in 27 and C in 11. The PTPS was created by a percutaneous transhepatic puncture into right portal vein and then through left portal vein to the hepatic segment of IVC followed by a prefabrication stress stent-graft placement at the very site. Results: Technical and functional success of 100% was achieved in all patients, without related complications. The postprocedural portal vein-IVC gradients mean 13 cmH 2 O was achieved with the follow-up period mean 493 days. No recurrence of variceal bleeding and controlled refractory ascites were achieved, and still more with primary patency rate of the involved vascular structure up to 94.8% at 365 days, much better than classic TIPS. Conclusions: Portacaval shunt creation using the prefabrication stress stent via percutaneous transhepatic technique is safe and feasible. the compact coincidence was obtained between the stent and the involved vessel with restoration of intrahepatic portal venous hemodynamics together with partial lowering of portal venous pressure and guaranteeing intrahepatic perfusion through right portal vein. It is also obviously to have postoperative prevention of shunt restenoses and lowering postoperative incidence of hepato-encephalopathy. (authors)

  10. Performance of Modular Prefabricated Architecture: Case Study-Based Review and Future Pathways

    Directory of Open Access Journals (Sweden)

    Fred Edmond Boafo

    2016-06-01

    Full Text Available Even though tightened building energy efficiency standards are implemented periodically in many countries, existing buildings continually consume a momentous quota of the total primary energy. Energy efficiency solutions range from material components to bulk systems. A technique of building construction, referred to as prefabricated architecture (prefab, is increasing in reputation. Prefab encompasses the offsite fabrication of building components to a greater degree of finish as bulk building structures and systems, and their assembly on-site. In this context, prefab improves the speed of construction, quality of architecture, efficiency of materials, and worker safety, while limiting environmental impacts of construction, as compared to conventional site-built construction practices. Quite recently, a 57 story skyscraper was built in 19 days using prefabricated modules. From the building physics point of view, the bulk systems and tighter integration method of prefab minimizes thermal bridges. This study seeks to clearly characterize the levels of prefab and to investigate the performance of modular prefab; considering acoustic constrain, seismic resistance, thermal behavior, energy consumption, and life cycle analysis of existing prefab cases and, thus, provides a dynamic case study-based review. Generally, prefab can be categorized into components, panels (2D, modules (3D, hybrids, and unitized whole buildings. On average, greenhouse gas emissions from conventional construction were higher than for modular construction, not discounting some individual discrepancies. Few studies have focused on monitored data on prefab and occupants’ comfort but additional studies are required to understand the public’s perception of the technology. The scope of the work examined will be of interest to building engineers, manufacturers, and energy experts, as well as serve as a foundational reference for future study.

  11. Numerical investigation on the prefabricated crack propagation of FV520B stainless steel

    Directory of Open Access Journals (Sweden)

    Juyi Pan

    Full Text Available FV520B is a common stainless steel for manufacturing centrifugal compressor impeller and shaft. The internal metal flaw destroys the continuity of the material matrix, resulting in the crack propagation fracture of the component, which seriously reduces the service life of the equipment. In this paper, Abaqus software was used to simulate the prefabricated crack propagation of FV520B specimen with unilateral gap. The results of static crack propagation simulation results show that the maximum value of stress–strain located at the tip of the crack and symmetrical distributed like a butterfly along the prefabricated crack direction, the maximum stress is 1990 MPa and the maximum strain is 9.489 × 10−3. The Mises stress and stress intensity factor KI increases with the increase of the expansion step, the critical value of crack initiation is reached at the 6th extension step. The dynamic crack propagation simulation shows that the crack propagation path is perpendicular to the load loading direction. Similarly, the maximum Mises stress located at the crack tip and is symmetrically distributed along the crack propagation direction. The critical stress range of the crack propagation is 23.3–43.4 MPa. The maximum value of stress–strain curve located at the 8th extension step, that is, the crack initiation point, the maximum stress is 55.22 MPa, and the maximum strain is 2.26 × 10−4. On the crack tip, the stress changed as 32.24–40.16 MPa, the strain is at 1.292 × 10−4–1.897 × 10−4. Keywords: FV520B, Crack propagation, Mises stress, Stress–strain, Numerical investigation

  12. Foot, leg, and ankle swelling

    Science.gov (United States)

    Swelling of the ankles - feet - legs; Ankle swelling; Foot swelling; Leg swelling; Edema - peripheral; Peripheral edema ... Foot, leg, and ankle swelling is common when the person also: Is overweight Has a blood clot in the leg Is older Has ...

  13. What Is a Foot and Ankle Surgeon?

    Science.gov (United States)

    ... A A | Print | Share What is a Foot & Ankle Surgeon? Foot and ankle surgeons are the surgical ... every age. What education has a foot and ankle surgeon received? After completing undergraduate education, the foot ...

  14. VT 10 ft Contour Lines generated from bare earth lidar - Chittenden

    Data.gov (United States)

    Vermont Center for Geographic Information — (Link to Metadata) ElevationContours_CN10T (10ft contours) was extracted from ElevationContours_CN2T (2ft contours), which was generated by USGS from the 2004...

  15. Automatic liver contouring for radiotherapy treatment planning

    International Nuclear Information System (INIS)

    Li, Dengwang; Kapp, Daniel S; Xing, Lei; Liu, Li

    2015-01-01

    To develop automatic and efficient liver contouring software for planning 3D-CT and four-dimensional computed tomography (4D-CT) for application in clinical radiation therapy treatment planning systems.The algorithm comprises three steps for overcoming the challenge of similar intensities between the liver region and its surrounding tissues. First, the total variation model with the L1 norm (TV-L1), which has the characteristic of multi-scale decomposition and an edge-preserving property, is used for removing the surrounding muscles and tissues. Second, an improved level set model that contains both global and local energy functions is utilized to extract liver contour information sequentially. In the global energy function, the local correlation coefficient (LCC) is constructed based on the gray level co-occurrence matrix both of the initial liver region and the background region. The LCC can calculate the correlation of a pixel with the foreground and background regions, respectively. The LCC is combined with intensity distribution models to classify pixels during the evolutionary process of the level set based method. The obtained liver contour is used as the candidate liver region for the following step. In the third step, voxel-based texture characterization is employed for refining the liver region and obtaining the final liver contours.The proposed method was validated based on the planning CT images of a group of 25 patients undergoing radiation therapy treatment planning. These included ten lung cancer patients with normal appearing livers and ten patients with hepatocellular carcinoma or liver metastases. The method was also tested on abdominal 4D-CT images of a group of five patients with hepatocellular carcinoma or liver metastases. The false positive volume percentage, the false negative volume percentage, and the dice similarity coefficient between liver contours obtained by a developed algorithm and a current standard delineated by the expert group

  16. Diabetes and Foot Problems

    Science.gov (United States)

    ... too much pressure on your toes. If your feet have changed shape, such as from Charcot’s foot, you may need ... care visit if you have changes in the shape of your feet loss of feeling in your feet peripheral artery ...

  17. Sesamoid Injuries in the Foot

    Science.gov (United States)

    ... on the ball of the foot when walking, running and jumping. Sesamoid injuries can involve the bones, tendons and/or surrounding ... on the ball of the foot, such as running, basketball, football, golf, tennis and ballet. ... of Sesamoid Injuries in the Foot There are three types of ...

  18. Foot Health Facts for Athletes

    Science.gov (United States)

    ... common foot problems affecting athletes: Prevent Foot & Ankle Running Injuries (downloadable PDF) Back-to-School Soccer Season Surgeons ... and Ankle Soccer is hard on the feet! Injuries to the foot and ankle can occur from running and side-to-side cutting, sliding or tackling ...

  19. Body contouring following massive weight loss

    Directory of Open Access Journals (Sweden)

    Vijay Langer

    2011-01-01

    Full Text Available Obesity is a global disease with epidemic proportions. Bariatric surgery or modified lifestyles go a long way in mitigating the vast weight gain. Patients following these interventions usually undergo massive weight loss. This results in redundant tissues in various parts of the body. Loose skin causes increased morbidity and psychological trauma. This demands various body contouring procedures that are usually excisional. These procedures are complex and part of a painstaking process that needs a committed patient and an industrious plastic surgeon. As complications in these patients can be quite frequent, both the patient and the surgeon need to be aware and willing to deal with them.

  20. The equivalent internal orientation and position noise for contour integration.

    Science.gov (United States)

    Baldwin, Alex S; Fu, Minnie; Farivar, Reza; Hess, Robert F

    2017-10-12

    Contour integration is the joining-up of local responses to parts of a contour into a continuous percept. In typical studies observers detect contours formed of discrete wavelets, presented against a background of random wavelets. This measures performance for detecting contours in the limiting external noise that background provides. Our novel task measures contour integration without requiring any background noise. This allowed us to perform noise-masking experiments using orientation and position noise. From these we measure the equivalent internal noise for contour integration. We found an orientation noise of 6° and position noise of 3 arcmin. Orientation noise was 2.6x higher in contour integration compared to an orientation discrimination control task. Comparing against a position discrimination task found position noise in contours to be 2.4x lower. This suggests contour integration involves intermediate processing that enhances the quality of element position representation at the expense of element orientation. Efficiency relative to the ideal observer was lower for the contour tasks (36% in orientation noise, 21% in position noise) compared to the controls (54% and 57%).

  1. Foot anthropometry and morphology phenomena.

    Science.gov (United States)

    Agić, Ante; Nikolić, Vasilije; Mijović, Budimir

    2006-12-01

    Foot structure description is important for many reasons. The foot anthropometric morphology phenomena are analyzed together with hidden biomechanical functionality in order to fully characterize foot structure and function. For younger Croatian population the scatter data of the individual foot variables were interpolated by multivariate statistics. Foot structure descriptors are influenced by many factors, as a style of life, race, climate, and things of the great importance in human society. Dominant descriptors are determined by principal component analysis. Some practical recommendation and conclusion for medical, sportswear and footwear practice are highlighted.

  2. Memory for pure tone sequences without contour.

    Science.gov (United States)

    Lefebvre, Christine; Jolicœur, Pierre

    2016-06-01

    We presented pure tones interspersed with white noise sounds to disrupt contour perception in an acoustic short-term memory (ASTM) experiment during which we recorded the electroencephalogram. The memory set consisted of seven stimuli, 0, 1, 2, 3, or 4 of which were to-be-remembered tones. We estimated each participant׳s capacity, K, for each set size and measured the amplitude of the SAN (sustained anterior negativity, an ERP related to acoustic short-term memory). We correlated their K slopes with their SAN amplitude slopes as a function of set size, and found a significant link between performance and the SAN: a larger increase in SAN amplitude was linked with a larger number of stimuli maintained in ASTM. The SAN decreased in amplitude in the later portion of the silent retention interval, but the correlation between the SAN and capacity remained strong. These results show the SAN is not an index of contour but rather an index of the maintenance of individual objects in STM. This article is part of a Special Issue entitled SI: Auditory working memory. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Human body contour data based activity recognition.

    Science.gov (United States)

    Myagmarbayar, Nergui; Yuki, Yoshida; Imamoglu, Nevrez; Gonzalez, Jose; Otake, Mihoko; Yu, Wenwei

    2013-01-01

    This research work is aimed to develop autonomous bio-monitoring mobile robots, which are capable of tracking and measuring patients' motions, recognizing the patients' behavior based on observation data, and providing calling for medical personnel in emergency situations in home environment. The robots to be developed will bring about cost-effective, safe and easier at-home rehabilitation to most motor-function impaired patients (MIPs). In our previous research, a full framework was established towards this research goal. In this research, we aimed at improving the human activity recognition by using contour data of the tracked human subject extracted from the depth images as the signal source, instead of the lower limb joint angle data used in the previous research, which are more likely to be affected by the motion of the robot and human subjects. Several geometric parameters, such as, the ratio of height to weight of the tracked human subject, and distance (pixels) between centroid points of upper and lower parts of human body, were calculated from the contour data, and used as the features for the activity recognition. A Hidden Markov Model (HMM) is employed to classify different human activities from the features. Experimental results showed that the human activity recognition could be achieved with a high correct rate.

  4. Study fidelity spatial contours of industrial robots

    Directory of Open Access Journals (Sweden)

    A. V. Ivanova

    2014-01-01

    Full Text Available The purpose of this paper to identify deviations fidelity spatial contours of industrial robots, determine the error pattern detected, and define the ways to solve the problem.The paper presents the research results of fidelity spatial contours done by Fanuc M- 710iC/50 industrial robot when moving along a predetermined path. The proposed method uses a QC20-W ballbar wireless system of Renishaw company, designed to diagnose the state of the measurement and playback linear and angular displacements of the CNC.The solutions to adapt the QC20-W ballbar system to the constructive peculiarities of industrial robots with five or more independently controlled axes are given. The stages of the preparation of diagnostic systems and software robot movements are described.According to study results of errors that arise while playing back the programmed motions of a fixed point of robot capture in three mutually perpendicular planes its practical accuracy has been defined when performing movements in a given region of the working area, thereby allowing us, eventually, to draw a conclusion on the possibility to use a robot in one technological process or another.The study has resulted in emerging the guidelines for the operation of industrial robots with five or more independently controlled axes. Using these guidelines enables us to increase the playback accuracy of the industrial robot to 0.01 mm.

  5. What is in a contour map? A region-based logical formalization of contour semantics

    Science.gov (United States)

    Usery, E. Lynn; Hahmann, Torsten

    2015-01-01

    Contours maps (such as topographic maps) compress the information of a function over a two-dimensional area into a discrete set of closed lines that connect points of equal value (isolines), striking a fine balance between expressiveness and cognitive simplicity. They allow humans to perform many common sense reasoning tasks about the underlying function (e.g. elevation).

  6. The visual image of prefabricated houses and new directions in the urban and architectural development of settlements

    Directory of Open Access Journals (Sweden)

    Živa Deu

    2000-01-01

    Full Text Available On the basis of the general directions of sustainable development in the physical space, new, also detailed valuable and normative definitions for organising settlements have been defined. Urban design and architectural aspects are directed to planning according to given natural possibilities and typical form and identity of built structures. Studies and detailed analyses have shown that formerly established standards of the building culture consist of numerous valuable characteristics, which are in accordance with the principles of sustainable development. Prefabricated building, just like classical building, is a constituent part of the new process in the formation of settlements. To attain our goal, radical changes will be needed in the architectural design of prefabricated houses, because their present architecture is global, cosmopolitan and not adapted to the different natural conditions and existing typical built structures in Slovenia.

  7. Design of online monitoring and forecasting system for electrical equipment temperature of prefabricated substation based on WSN

    Science.gov (United States)

    Qi, Weiran; Miao, Hongxia; Miao, Xuejiao; Xiao, Xuanxuan; Yan, Kuo

    2016-10-01

    In order to ensure the safe and stable operation of the prefabricated substations, temperature sensing subsystem, temperature remote monitoring and management subsystem, forecast subsystem are designed in the paper. Wireless temperature sensing subsystem which consists of temperature sensor and MCU sends the electrical equipment temperature to the remote monitoring center by wireless sensor network. Remote monitoring center can realize the remote monitoring and prediction by monitoring and management subsystem and forecast subsystem. Real-time monitoring of power equipment temperature, history inquiry database, user management, password settings, etc., were achieved by monitoring and management subsystem. In temperature forecast subsystem, firstly, the chaos of the temperature data was verified and phase space is reconstructed. Then Support Vector Machine - Particle Swarm Optimization (SVM-PSO) was used to predict the temperature of the power equipment in prefabricated substations. The simulation results found that compared with the traditional methods SVM-PSO has higher prediction accuracy.

  8. Pitch contour impairment in congenital amusia: New insights from the Self-paced Audio-visual Contour Task (SACT.

    Directory of Open Access Journals (Sweden)

    Xuejing Lu

    Full Text Available Individuals with congenital amusia usually exhibit impairments in melodic contour processing when asked to compare pairs of melodies that may or may not be identical to one another. However, it is unclear whether the impairment observed in contour processing is caused by an impairment of pitch discrimination, or is a consequence of poor pitch memory. To help resolve this ambiguity, we designed a novel Self-paced Audio-visual Contour Task (SACT that evaluates sensitivity to contour while placing minimal burden on memory. In this task, participants control the pace of an auditory contour that is simultaneously accompanied by a visual contour, and they are asked to judge whether the two contours are congruent or incongruent. In Experiment 1, melodic contours varying in pitch were presented with a series of dots that varied in spatial height. Amusics exhibited reduced sensitivity to audio-visual congruency in comparison to control participants. To exclude the possibility that the impairment arises from a general deficit in cross-modal mapping, Experiment 2 examined sensitivity to cross-modal mapping for two other auditory dimensions: timbral brightness and loudness. Amusics and controls were significantly more sensitive to large than small contour changes, and to changes in loudness than changes in timbre. However, there were no group differences in cross-modal mapping, suggesting that individuals with congenital amusia can comprehend spatial representations of acoustic information. Taken together, the findings indicate that pitch contour processing in congenital amusia remains impaired even when pitch memory is relatively unburdened.

  9. Pitch contour impairment in congenital amusia: New insights from the Self-paced Audio-visual Contour Task (SACT).

    Science.gov (United States)

    Lu, Xuejing; Sun, Yanan; Ho, Hao Tam; Thompson, William Forde

    2017-01-01

    Individuals with congenital amusia usually exhibit impairments in melodic contour processing when asked to compare pairs of melodies that may or may not be identical to one another. However, it is unclear whether the impairment observed in contour processing is caused by an impairment of pitch discrimination, or is a consequence of poor pitch memory. To help resolve this ambiguity, we designed a novel Self-paced Audio-visual Contour Task (SACT) that evaluates sensitivity to contour while placing minimal burden on memory. In this task, participants control the pace of an auditory contour that is simultaneously accompanied by a visual contour, and they are asked to judge whether the two contours are congruent or incongruent. In Experiment 1, melodic contours varying in pitch were presented with a series of dots that varied in spatial height. Amusics exhibited reduced sensitivity to audio-visual congruency in comparison to control participants. To exclude the possibility that the impairment arises from a general deficit in cross-modal mapping, Experiment 2 examined sensitivity to cross-modal mapping for two other auditory dimensions: timbral brightness and loudness. Amusics and controls were significantly more sensitive to large than small contour changes, and to changes in loudness than changes in timbre. However, there were no group differences in cross-modal mapping, suggesting that individuals with congenital amusia can comprehend spatial representations of acoustic information. Taken together, the findings indicate that pitch contour processing in congenital amusia remains impaired even when pitch memory is relatively unburdened.

  10. Prefabricated Cervical Skin Flaps for Hemi-Facial Resurfacing: Elucidating the Natural History of Postoperative Edema Using Indocyanine Green.

    Science.gov (United States)

    Li, Ke; Min, Peiru; Sadigh, Parviz; Grassetti, Luca; Lazzeri, Davide; Torresetti, Matteo; Marsili, Riccardo; Feng, Shaoqing; Liu, Ningfei; Zhang, Yi Xin

    2018-02-01

    The increases in capillary wall permeability and capillary hydrostatic pressure are considered to be the causes for the acute swelling seen in flaps; however, disruption of the circulating flap lymphatics could be another contributory factor. In this study we monitor the development of flap edema in a series of 18 prefabricated flaps and aim to delineate the natural history of this phenomenon by use of lymphography. Postoperative swelling was monitored in a series of 18 pre-expanded prefabricated cervical skin flaps used for hemi-facial burns-scar resurfacing. Time to spontaneous resolution, presence or absence of venous congestion, and clinical outcome were recorded. In two cases, indocyanine-green (ICG) lymphography was used to monitor the dermal backflow pattern until swelling had completely resolved. Average moving velocity of ICG after injection as well as flap thickness was also recorded over the follow-up period. The average moving velocity of ICG in the flap lymphatics improved from 0.48 cm/min to 1.5 cm/min in the first 12 days after flap transfer. The dermal backflow pattern was stardust in the first 12 days, indicating moderate lymphedema, transforming to splash from week three, and a robust collecting lymphatic vessel occurring from the fifth month, indicating mild lymphedema and lymphatic channel recovery, respectively. Transient swelling was observed in all prefabricated flaps in our series. We postulate that this is mostly secondary to lymphatic disruption that subsides as lymphangiogenesis takes place. ICG lymphography is an inexpensive, safe, and easy-to-use imaging technology that could be used in the monitoring of postoperative lymphedema seen in prefabricated flaps.

  11. Three-dimensional modelling of an embankment built on a soft soil improved with prefabricated vertical drains

    OpenAIRE

    Venda Oliveira, P.J.; Cruz, R.F.P.M.L.; Lemos, L.J.L.; Almeida e Sousa, J.N.V.

    2015-01-01

    This work compares the field measurements of a non-symmetric embankment built on a Portuguese soft soil improved with prefabricated vertical drains (PVDs), with the numerical predictions of a 3D modelling where the PVDs are simulated according to the field flow conditions. The change in the permeability with the void ratio and the effect of the smear zone are also included in the numerical analysis. The numerical predictions are compared with the field data in terms of settlement, horizontal ...

  12. Biomechanically acquired foot types

    International Nuclear Information System (INIS)

    Weissman, S.D.

    1989-01-01

    Over the years, orthopedics of the foot has gone through many stages and phases, each of which has spawned a whole vocabulary of its own. According the author, today we are in the biomechanical age, which represents a step forward in understanding the mechanisms governing the functions of the lower extremity. A great deal of scientific research on the various foot types and pathological entities is now being performed. This paper discusses how, from a radiographic point of view, a knowledge of certain angular relationships must be achieved before one can perform a biomechanical evaluation. In order to validate the gross clinical findings, following an examination of a patient, a biomechanical evaluation can be performed on the radiographs taken. It must be remembered, however, that x-rays are never the sole means of making a diagnosis. They are just one of many findings that must be put together to arrive at a pertinent clinical assessment or diagnosis

  13. The diabetic foot

    International Nuclear Information System (INIS)

    Vestring, T.; Fiedler, R.; Greitemann, B.; Sciuk, J.; Peters, P.E.

    1995-01-01

    Familiarity with the spectrum of findings in the different imaging modalities appears essential. Radiographically, significant changes include Charcot joints of the tarsus (destructive type) and bone absorption of the forefoot (mutilating type). In diabetic foot problems, magnetic resonance imaging and leukocyte scintigraphy appear to be the most effective tools for detection of osteomyelitis, and a negative study makes osteomyelitis unlikely. However, the findings of both techniques in active, noninfected neuropathic osteoarthropathy may be indistinguishable from those of osteomyelitis. (orig.) [de

  14. Normal foot and ankle

    International Nuclear Information System (INIS)

    Weissman, S.D.

    1989-01-01

    The foot may be thought of as a bag of bones tied tightly together and functioning as a unit. The bones re expected to maintain their alignment without causing symptomatology to the patient. The author discusses a normal radiograph. The bones must have normal shape and normal alignment. The density of the soft tissues should be normal and there should be no fractures, tumors, or foreign bodies

  15. Data integrity systems for organ contours in radiation therapy planning.

    Science.gov (United States)

    Shah, Veeraj P; Lakshminarayanan, Pranav; Moore, Joseph; Tran, Phuoc T; Quon, Harry; Deville, Curtiland; McNutt, Todd R

    2018-06-12

    The purpose of this research is to develop effective data integrity models for contoured anatomy in a radiotherapy workflow for both real-time and retrospective analysis. Within this study, two classes of contour integrity models were developed: data driven models and contiguousness models. The data driven models aim to highlight contours which deviate from a gross set of contours from similar disease sites and encompass the following regions of interest (ROI): bladder, femoral heads, spinal cord, and rectum. The contiguousness models, which individually analyze the geometry of contours to detect possible errors, are applied across many different ROI's and are divided into two metrics: Extent and Region Growing over volume. After analysis, we found that 70% of detected bladder contours were verified as suspicious. The spinal cord and rectum models verified that 73% and 80% of contours were suspicious respectively. The contiguousness models were the most accurate models and the Region Growing model was the most accurate submodel. 100% of the detected noncontiguous contours were verified as suspicious, but in the cases of spinal cord, femoral heads, bladder, and rectum, the Region Growing model detected additional two to five suspicious contours that the Extent model failed to detect. When conducting a blind review to detect false negatives, it was found that all the data driven models failed to detect all suspicious contours. The Region Growing contiguousness model produced zero false negatives in all regions of interest other than prostate. With regards to runtime, the contiguousness via extent model took an average of 0.2 s per contour. On the other hand, the region growing method had a longer runtime which was dependent on the number of voxels in the contour. Both contiguousness models have potential for real-time use in clinical radiotherapy while the data driven models are better suited for retrospective use. © 2018 The Authors. Journal of Applied Clinical

  16. Contour Tracking Control for the REMUS Autonomous Underwater Vehicle

    National Research Council Canada - National Science Library

    Van Reet, Alan R

    2005-01-01

    In the interest of enhancing the capabilities of autonomous underwater vehicles used in US Naval Operations, controlling vehicle position to follow depth contours presents exciting potential for navigation...

  17. Contour plotting programs for printer and Calcomp plotter

    International Nuclear Information System (INIS)

    Moller, P.

    1980-07-01

    Contour plotting programs for plotting contour diagrams on printers or Calcomp plotters are described. The subroutines also exist in versions that are useful for the special application of finding minima and saddlepoints of nuclear potential energy surfaces generated by the subroutine PETR3 of another program package. For the general user, however, the most interesting aspect of the plotting package is probably the possibility of generating printer contour plots. The plotting of printer contour plots is a very fast and convenient way of displaying two-dimensional functions. 3 figures

  18. India-Pakistan: Contours of Relationship

    Directory of Open Access Journals (Sweden)

    Devika Mittal

    2016-06-01

    Full Text Available Even after about 70 years of separation, India and Pakistan continue to live in the prison of the past. The rhetoric of partition is still alive in the memory of the people of both the countries. They have constructed fixed, unchanging and competing images for each other. While Pakistan became an Islamic Republic, India adopted secularism, thereby, negating the two-nation theory. The ‘differences’ along with memories of partition has made Indian and Pakistani to remain in permanent hostile situation. The leaders of the two countries try to settle their disputes but fails because of lack of support from their social and political institutions. Since its coming into power in 2014, the NDA government under the Indian Prime Minister, Mr. Narendra Modi has managed to engage the Pakistani establishment, despite many problems between the two countries. This article tries to highlight upon the contours of relationships post-2014.

  19. Automatic Contour Extraction from 2D Image

    Directory of Open Access Journals (Sweden)

    Panagiotis GIOANNIS

    2011-03-01

    Full Text Available Aim: To develop a method for automatic contour extraction from a 2D image. Material and Method: The method is divided in two basic parts where the user initially chooses the starting point and the threshold. Finally the method is applied to computed tomography of bone images. Results: An interesting method is developed which can lead to a successful boundary extraction of 2D images. Specifically data extracted from a computed tomography images can be used for 2D bone reconstruction. Conclusions: We believe that such an algorithm or part of it can be applied on several other applications for shape feature extraction in medical image analysis and generally at computer graphics.

  20. Contour Propagation With Riemannian Elasticity Regularization

    DEFF Research Database (Denmark)

    Bjerre, Troels; Hansen, Mads Fogtmann; Sapru, W.

    2011-01-01

    Purpose/Objective(s): Adaptive techniques allow for correction of spatial changes during the time course of the fractionated radiotherapy. Spatial changes include tumor shrinkage and weight loss, causing tissue deformation and residual positional errors even after translational and rotational image...... the planning CT onto the rescans and correcting to reflect actual anatomical changes. For deformable registration, a free-form, multi-level, B-spline deformation model with Riemannian elasticity, penalizing non-rigid local deformations, and volumetric changes, was used. Regularization parameters was defined...... on the original delineation and tissue deformation in the time course between scans form a better starting point than rigid propagation. There was no significant difference of locally and globally defined regularization. The method used in the present study suggests that deformed contours need to be reviewed...

  1. CMOS image sensor with contour enhancement

    Science.gov (United States)

    Meng, Liya; Lai, Xiaofeng; Chen, Kun; Yuan, Xianghui

    2010-10-01

    Imitating the signal acquisition and processing of vertebrate retina, a CMOS image sensor with bionic pre-processing circuit is designed. Integration of signal-process circuit on-chip can reduce the requirement of bandwidth and precision of the subsequent interface circuit, and simplify the design of the computer-vision system. This signal pre-processing circuit consists of adaptive photoreceptor, spatial filtering resistive network and Op-Amp calculation circuit. The adaptive photoreceptor unit with a dynamic range of approximately 100 dB has a good self-adaptability for the transient changes in light intensity instead of intensity level itself. Spatial low-pass filtering resistive network used to mimic the function of horizontal cell, is composed of the horizontal resistor (HRES) circuit and OTA (Operational Transconductance Amplifier) circuit. HRES circuit, imitating dendrite of the neuron cell, comprises of two series MOS transistors operated in weak inversion region. Appending two diode-connected n-channel transistors to a simple transconductance amplifier forms the OTA Op-Amp circuit, which provides stable bias voltage for the gate of MOS transistors in HRES circuit, while serves as an OTA voltage follower to provide input voltage for the network nodes. The Op-Amp calculation circuit with a simple two-stage Op-Amp achieves the image contour enhancing. By adjusting the bias voltage of the resistive network, the smoothing effect can be tuned to change the effect of image's contour enhancement. Simulations of cell circuit and 16×16 2D circuit array are implemented using CSMC 0.5μm DPTM CMOS process.

  2. Pre-fabricated nanorods in RE–Ba–Cu–O superconductors

    International Nuclear Information System (INIS)

    Khatri, N D; Majkic, G; Shi, T; Selvamanickam, V; Chen, Y

    2013-01-01

    Pre-fabrication of metallic nanorods on biaxially textured templates has been explored in this study to introduce flux pinning centers in RE–Ba–Cu–O (REBCO, RE =rare earth) based superconductors. Pt nanorods were deposited by an electron beam assisted deposition method on LaMnO 3 -capped biaxially textured IBAD-(ion beam assisted deposition) substrates. Well-controlled nanorods with varying diameter (50–120 nm), length (up to 1 μm), orientation and unit cell size were grown over an area of 120–150 μm 2 . The nanorod-decorated samples were then deposited with Gd–Y–Ba–Cu–O ((Gd, Y)BCO) by metal organic chemical vapor deposition (MOCVD). The Pt nanorods remain in their positions during MOCVD and become embedded in the (Gd, Y)BCO matrix, although they suffer creep-induced shape deformation due to exposure to elevated temperature. Higher unit cell size, longer nanorods, and nanorods oriented at an angle to the substrate normal adversely affect the epitaxy of the (Gd, Y)BCO film due to formation of a-axis grains. The observed current-carrying capacity of the Pt nanorod sample is lower than its corresponding reference sample without any nanorods and processed under identical conditions, but it decreases at a slower rate with increasing magnetic field. Potential routes to improve the performance while retaining the desirable characteristics of controlled nanorod direction and density are discussed. (paper)

  3. Effect of surface treatment of prefabricated teeth on shear bond strength of orthodontic brackets.

    Science.gov (United States)

    Cumerlato, Marina; Lima, Eduardo Martinelli de; Osorio, Leandro Berni; Mota, Eduardo Gonçalves; Menezes, Luciane Macedo de; Rizzatto, Susana Maria Deon

    2017-01-01

    The aim of this in vitro study was to evaluate and compare the effects of grinding, drilling, sandblasting, and ageing prefabricated teeth (PfT) on the shear bond strength (SBS) of orthodontic brackets, as well as the effects of surface treatments on the adhesive remnant index (ARI). One-hundred-ninety-two PfT were divided into four groups (n = 48): Group 1, no surface treatment was done; Group 2, grinding was performed with a cylindrical diamond bur; Group 3, two drillings were done with a spherical diamond bur; Group 4, sandblasting was performed with 50-µm aluminum oxide. Before the experiment, half of the samples stayed immersed in distilled water at 37oC for 90 days. Brackets were bonded with Transbond XT and shear strength tests were carried out using a universal testing machine. SBS were compared by surface treatment and by ageing with two-way ANOVA, followed by Tukey's test. ARI scores were compared between surface treatments with Kruskal-Wallis test followed by Dunn's test. Surface treatments on PfT enhanced SBS of brackets (pgrinding) (pgrinding. There was a positive correlation between SBS and ARI.

  4. Prefabrication of axial vascularized tissue engineering coral bone by an arteriovenous loop: a better model.

    Science.gov (United States)

    Dong, Qing-shan; Shang, Hong-tao; Wu, Wei; Chen, Fu-lin; Zhang, Jun-rui; Guo, Jia-ping; Mao, Tian-qiu

    2012-08-01

    The most important problem for the survival of thick 3-dimensional tissues is the lack of vascularization in the context of bone tissue engineering. In this study, a modified arteriovenous loop (AVL) was developed to prefabricate an axial vascularized tissue engineering coral bone in rabbit, with comparison of the arteriovenous bundle (AVB) model. An arteriovenous fistula between rabbit femoral artery and vein was anastomosed to form an AVL. It was placed in a circular side groove of the coral block. The complex was wrapped with an expanded-polytetrafluoroethylene membrane and implanted beneath inguinal skin. After 2, 4, 6 and 8 weeks, the degree of vascularization was evaluated by India ink perfusion, histological examination, vascular casts, and scanning electron microscopy images of vascular endangium. Newly formed fibrous tissues and vasculature extended over the surfaces and invaded the interspaces of entire coral block. The new blood vessels robustly sprouted from the AVL. Those invaginated cavities in the vascular endangium from scanning electron microscopy indicated vessel's sprouted pores. Above indexes in AVL model are all superior to that in AVB model, indicating that the modified AVL model could more effectively develop vascularization in larger tissue engineering bone. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Utilization of Construction Waste Composite Powder Materials as Cementitious Materials in Small-Scale Prefabricated Concrete

    Directory of Open Access Journals (Sweden)

    Cuizhen Xue

    2016-01-01

    Full Text Available The construction and demolition wastes have increased rapidly due to the prosperity of infrastructure construction. For the sake of effectively reusing construction wastes, this paper studied the potential use of construction waste composite powder material (CWCPM as cementitious materials in small-scale prefabricated concretes. Three types of such concretes, namely, C20, C25, and C30, were selected to investigate the influences of CWCPM on their working performances, mechanical properties, and antipermeability and antifrost performances. Also the effects of CWCPM on the morphology, hydration products, and pore structure characteristics of the cement-based materials were analyzed. The results are encouraging. Although CWCPM slightly decreases the mechanical properties of the C20 concrete and the 7 d compressive strengths of the C25 and C30 concretes, the 28 d compressive strength and the 90 d flexural strength of the C25 and C30 concretes are improved when CWCPM has a dosage less than 30%; CWCPM improves the antipermeability and antifrost performances of the concretes due to its filling and pozzolanic effects; the best improvement is obtained at CWCPM dosage of 30%; CWCPM optimizes cement hydration products, refines concrete pore structure, and gives rise to reasonable pore size distribution, therefore significantly improving the durability of the concretes.

  6. Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment

    Science.gov (United States)

    DE JESUS TAVAREZ, Rudys Rodolfo; BONACHELA, Wellington Cardoso; XIBLE, Anuar Antônio

    2011-01-01

    Objective The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. Material and Methods Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey’s post-hoc test (pabutment connection may develop a role on the vertical misfit at the implant/abutment interface. PMID:21437464

  7. Carbon footprint hotspots of prefabricated sandwich panels for hostel construction in Perlis

    Science.gov (United States)

    Razali, Norashikin; Ayob, Afizah; Chandra, Muhammad Erwan Shah; Zaki, Mohd Faiz Mohammad; Ahmad, Abdul Ghapar

    2017-10-01

    Sustainable design and construction have gained increasing research interest, and reduction of carbon from building construction has become the main focus of environmental strategies in Malaysia. This study uses life cycle assessment and life cycle inventory analysis frameworks to estimate the amount of carbon footprint expressed in carbon dioxide equivalent tons (CO2e) produced by manufacturing prefabricated Industrialized Building System sandwich panels and its installation for a five-story hostel in Perlis, Malaysia. Results show that the carbon footprint hotspots were centered on boiler machine operation and cement with 4.52 and 369.04 tons CO2e, respectively. This finding is due to the extensive energy used for steam heating and high engine rating for the boiler. However, for cement, the carbon footprint hotspots are caused by the large quantity of cement applied in shotcrete mixture and its high extraction and production CO2 emission values. The overall onsite materials generated 96.36% of the total carbon footprint. These carbon footprint hotspot results constitute a necessary base for the Malaysian government in accomplishing an adequate dimensioning of carbon emissions in the building sector.

  8. New method for protecting mine roadways in thin coal seams by means of prefabricated yielding blocks

    Energy Technology Data Exchange (ETDEWEB)

    Peknik, J

    1983-05-01

    The use of concrete blocks for strata control in mine roadways driven in thin coal seams is evaluated. Two types of prefabricated blocks are used: BZT blocks made of reinforced concrete and yielding elements or popilbet blocks made of a mixture of fly ash (from coal power plants) and concrete. When the popilbet blocks were used no yielding elements were necessary. Mechanical properties of blocks made of reinforced concrete were controlled by yielding elements. Mechanical properties (compression strength) of the popilbet blocks were controlled by proportion of water, cement and fly ash. The BZT and the popilbet blocks were used for strata control in mine roadways in coal seams from 60 to 80 cm thick and dip angle from 5 to 18 degrees. Use of the BZT and the popilbet blocks reduced roadway deformation by about 50% in comparison to traditional strata control methods (timber cribbings, use of waste rock, etc.). Use of the blocks is explained. The BZT and the popilbet blocks were placed in a roadway wall. Height of the block wall equaled coal seam thickness. Yielding arched steel supports and timber liners were used for strata control in the roadway. The popilbet blocks were 50% less expensive than the BZT blocks. 9 references

  9. Bond strength of stainless steel orthodontic brackets bonded to prefabricated acrylic teeth.

    Science.gov (United States)

    Wan Abdul Razak, Wan Salbiah; Sherriff, Martyn; Bister, Dirk; Seehra, Jadbinder

    2017-06-01

    The purpose of this in-vitro study was to evaluate the force to debond stainless steel orthodontic brackets bonded to acrylic teeth using different combinations of adhesive and surface treatments. One hundred prefabricated upper lateral incisor acrylic teeth were divided into 4 equal groups: Transbond XT® adhesive only (Group 1, control), Transbond XT® adhesive with sandblasting (Group 2), Transbond XT® adhesive with abrasion / + methyl methacrylate (MMA) (Group 3) and Triad® Gel only (Group 4). The force in Newtons (N) to debond the brackets was measured. One-way analysis of variance (ANOVA) and pairwise multi-comparison of means (Šidak's adjustment) were undertaken. The highest force to debond was recorded for Group 2 (275.7 N; SD 89.0) followed by Group 3 (241.9 N; SD 76.0), Group 1 (142.7 N; SD 36.7) and Group 4 (67.9 N; SD 21.1). Significant differences in bond strength measurements between the experimental groups were detected. Mean force values for the groups revealed no significant differences between Group 2 and Group 3 (p>0.05). Both sandblasting and surface abrasion/+ application of methyl methacrylate (MMA) in combination with Transbond XT® adhesive are recommended for bonding stainless orthodontic brackets to acrylic teeth.

  10. Numerical Analysis of Prefabricated Steel-Concrete Composite Floor in Typical Lipsk Building

    Directory of Open Access Journals (Sweden)

    Lacki Piotr

    2017-12-01

    Full Text Available The aim of the work was to perform numerical analysis of a steel-concrete composite floor located in a LIPSK type building. A numerical model of the analytically designed floor was performed. The floor was in a six-storey, retail and service building. The thickness of a prefabricated slab was 100 mm. The two-row, crisscrossed reinforcement of the slab was made from φ16 mm rods with a spacing of 150 x 200 mm. The span of the beams made of steel IPE 160 profiles was 6.00 m and they were spaced every 1.20 m. The steelconcrete composite was obtained using 80×16 Nelson fasteners. The numerical analysis was carried out using the ADINA System based on the Finite Element Method. The stresses and strains in the steel and concrete elements, the distribution of the forces in the reinforcement bars and cracking in concrete were evaluated. The FEM model was made from 3D-solid finite elements (IPE profile and concrete slab and truss elements (reinforcement bars. The adopted steel material model takes into consideration the plastic state, while the adopted concrete material model takes into account material cracks.

  11. Powerful Software to Simulate Soil Consolidation Problems with Prefabricated Vertical Drains

    Directory of Open Access Journals (Sweden)

    Gonzalo García-Ros

    2018-02-01

    Full Text Available The present work describes the program Simulation of Consolidation with Vertical Drains (SICOMED_2018, a tool for the solution of consolidation processes in heterogeneous soils, with totally or partially penetrating prefabricated vertical drains (PVD and considering both the effects of the smear zone, generated when introducing the drain into the ground, and the limitation in the discharge capacity of the drain. In order to provide a completely free program, the code Next-Generation Simulation Program with Integrated Circuit Emphasis (Ngspice has been used as a numerical tool while the Matrix Laboratory (MATLAB code was used to program and create an interface with the user through interactive screens. In this way, SICOMED_2018 is presented as an easy-to-use and intuitive program, with a simple graphical interface that allows the user to enter all the soil properties and geometry of the problem without having to resort to a complex software package that requires programming. Illustrative applications describe both the versatility of the program and the reliability of its numerical solutions.

  12. Relationship between static foot posture and foot mobility

    Directory of Open Access Journals (Sweden)

    McPoil Thomas G

    2011-01-01

    Full Text Available Abstract Background It is not uncommon for a person's foot posture and/or mobility to be assessed during a clinical examination. The exact relationship, however, between static posture and mobility is not known. Objective The purpose of this study was to determine the degree of association between static foot posture and mobility. Method The static foot posture and foot mobility of 203 healthy individuals was assessed and then analyzed to determine if low arched or "pronated" feet are more mobile than high arched or "supinated" feet. Results The study demonstrated that those individuals with a lower standing dorsal arch height and/or a wider standing midfoot width had greater mobility in their foot. In addition, those individuals with higher Foot Posture Index (FPI values demonstrated greater mobility and those with lower FPI values demonstrated less mobility. Finally, the amount of foot mobility that an individual has can be predicted reasonably well using either a 3 or 4 variable linear regression model. Conclusions Because of the relationship between static foot posture and mobility, it is recommended that both be assessed as part of a comprehensive evaluation of a individual with foot problems.

  13. Combining prior day contours to improve automated prostate segmentation

    International Nuclear Information System (INIS)

    Godley, Andrew; Sheplan Olsen, Lawrence J.; Stephans, Kevin; Zhao Anzi

    2013-01-01

    Purpose: To improve the accuracy of automatically segmented prostate, rectum, and bladder contours required for online adaptive therapy. The contouring accuracy on the current image guidance [image guided radiation therapy (IGRT)] scan is improved by combining contours from earlier IGRT scans via the simultaneous truth and performance level estimation (STAPLE) algorithm. Methods: Six IGRT prostate patients treated with daily kilo-voltage (kV) cone-beam CT (CBCT) had their original plan CT and nine CBCTs contoured by the same physician. Three types of automated contours were produced for analysis. (1) Plan: By deformably registering the plan CT to each CBCT and then using the resulting deformation field to morph the plan contours to match the CBCT anatomy. (2) Previous: The contour set drawn by the physician on the previous day CBCT is similarly deformed to match the current CBCT anatomy. (3) STAPLE: The contours drawn by the physician, on each prior CBCT and the plan CT, are deformed to match the CBCT anatomy to produce multiple contour sets. These sets are combined using the STAPLE algorithm into one optimal set. Results: Compared to plan and previous, STAPLE improved the average Dice's coefficient (DC) with the original physician drawn CBCT contours to a DC as follows: Bladder: 0.81 ± 0.13, 0.91 ± 0.06, and 0.92 ± 0.06; Prostate: 0.75 ± 0.08, 0.82 ± 0.05, and 0.84 ± 0.05; and Rectum: 0.79 ± 0.06, 0.81 ± 0.06, and 0.85 ± 0.04, respectively. The STAPLE results are within intraobserver consistency, determined by the physician blindly recontouring a subset of CBCTs. Comparing plans recalculated using the physician and STAPLE contours showed an average disagreement less than 1% for prostate D98 and mean dose, and 5% and 3% for bladder and rectum mean dose, respectively. One scan takes an average of 19 s to contour. Using five scans plus STAPLE takes less than 110 s on a 288 core graphics processor unit. Conclusions: Combining the plan and all prior days via

  14. Cheap contouring of costly functions: the Pilot Approximation Trajectory algorithm

    International Nuclear Information System (INIS)

    Huttunen, Janne M J; Stark, Philip B

    2012-01-01

    The Pilot Approximation Trajectory (PAT) contour algorithm can find the contour of a function accurately when it is not practical to evaluate the function on a grid dense enough to use a standard contour algorithm, for instance, when evaluating the function involves conducting a physical experiment or a computationally intensive simulation. PAT relies on an inexpensive pilot approximation to the function, such as interpolating from a sparse grid of inexact values, or solving a partial differential equation (PDE) numerically using a coarse discretization. For each level of interest, the location and ‘trajectory’ of an approximate contour of this pilot function are used to decide where to evaluate the original function to find points on its contour. Those points are joined by line segments to form the PAT approximation of the contour of the original function. Approximating a contour numerically amounts to estimating a lower level set of the function, the set of points on which the function does not exceed the contour level. The area of the symmetric difference between the true lower level set and the estimated lower level set measures the accuracy of the contour. PAT measures its own accuracy by finding an upper confidence bound for this area. In examples, PAT can estimate a contour more accurately than standard algorithms, using far fewer function evaluations than standard algorithms require. We illustrate PAT by constructing a confidence set for viscosity and thermal conductivity of a flowing gas from simulated noisy temperature measurements, a problem in which each evaluation of the function to be contoured requires solving a different set of coupled nonlinear PDEs. (paper)

  15. Automatic re-contouring in 4D radiotherapy

    International Nuclear Information System (INIS)

    Lu, Weiguo; Olivera, Gustavo H; Chen, Quan; Chen, Ming-Li; Ruchala, Kenneth J

    2006-01-01

    Delineating regions of interest (ROIs) on each phase of four-dimensional (4D) computed tomography (CT) images is an essential step for 4D radiotherapy. The requirement of manual phase-by-phase contouring prohibits the routine use of 4D radiotherapy. This paper develops an automatic re-contouring algorithm that combines techniques of deformable registration and surface construction. ROIs are manually contoured slice-by-slice in the reference phase image. A reference surface is constructed based on these reference contours using a triangulated surface construction technique. The deformable registration technique provides the voxel-to-voxel mapping between the reference phase and the test phase. The vertices of the reference surface are displaced in accordance with the deformation map, resulting in a deformed surface. The new contours are reconstructed by cutting the deformed surface slice-by-slice along the transversal, sagittal or coronal direction. Since both the inputs and outputs of our automatic re-contouring algorithm are contours, it is relatively easy to cope with any treatment planning system. We tested our automatic re-contouring algorithm using a deformable phantom and 4D CT images of six lung cancer patients. The proposed algorithm is validated by visual inspections and quantitative comparisons of the automatic re-contours with both the gold standard segmentations and the manual contours. Based on the automatic delineated ROIs, changes of tumour and sensitive structures during respiration are quantitatively analysed. This algorithm could also be used to re-contour daily images for treatment evaluation and adaptive radiotherapy

  16. Contour adaptation reduces the spreading of edge induced colors.

    Science.gov (United States)

    Coia, Andrew J; Crognale, Michael A

    2017-04-25

    Brief exposure to flickering achromatic outlines of an area causes a reduction in the brightness contrast of the surface inside the area. This contour adaptation to achromatic contours does not reduce surface contrast when the surface is chromatic (the saturation or colorimetric purity of the surface is maintained). In addition to reducing the brightness of physical luminance contrast, contour adaptation also reduces (or even reverses) the illusory brightness contrast seen in the Craik-O'Brien-Cornsweet illusion, in which two physically identical grey areas appear different brightness because of a sharp luminance edge separating them. Chromatic color spreading illusions also occur with chromatic inducing edges, and an unanswered question is whether contour adaptation can reduce the perceived contrast of illusory color spreading from edges, even though it cannot reduce the perceived contrast of physical surface color. The current studies use a color spreading illusion known as the watercolor effect in order to test whether illusory color spreading is affected by contour adaptation. The general findings of physical achromatic contrast being reduced and chromatic contrast being robust to contour adaptation were replicated. However, both illusory brightness and color were reduced by contour adaptation, even when the illusion edges only differed in chromatic contrast with each other and the background. Additional studies adapting to chromatic contours showed opposite effects on illusory color contrast than achromatic adaptation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Analysis of contour images using optics of spiral beams

    Science.gov (United States)

    Volostnikov, V. G.; Kishkin, S. A.; Kotova, S. P.

    2018-03-01

    An approach is outlined to the recognition of contour images using computer technology based on coherent optics principles. A mathematical description of the recognition process algorithm and the results of numerical modelling are presented. The developed approach to the recognition of contour images using optics of spiral beams is described and justified.

  18. Hand-Geometry Recognition Based on Contour Parameters

    NARCIS (Netherlands)

    Veldhuis, Raymond N.J.; Bazen, A.M.; Booij, W.D.T.; Hendrikse, A.J.; Jain, A.K.; Ratha, N.K.

    This paper demonstrates the feasibility of a new method of hand-geometry recognition based on parameters derived from the contour of the hand. The contour is completely determined by the black-and-white image of the hand and can be derived from it by means of simple image-processing techniques. It

  19. Adaptive Pseudo Dilation for Gestalt Edge Grouping and Contour Detection

    NARCIS (Netherlands)

    Papari, Giuseppe; Petkov, Nicolai

    2008-01-01

    We consider the problem of detecting object contours in natural images. In many cases, local luminance changes turn out to be stronger in textured areas than on object contours. Therefore, local edge features, which only look at a small neighborhood of each pixel, cannot be reliable indicators of

  20. Automatic programming of grinding robot restoration of contours

    Directory of Open Access Journals (Sweden)

    Are Willersrud

    1995-07-01

    Full Text Available A new programming method has been developed for grinding robots. Instead of using the conventional jog-and-teach method, the workpiece contour is automatically tracked by the robot. During the tracking, the robot position is stored in the robot control system every 8th millisecond. After filtering and reducing this contour data, a robot program is automatically generated.

  1. Automatic programming of grinding robot restoration of contours

    OpenAIRE

    Are Willersrud; Fred Godtliebsen; Trygve Thomessen

    1995-01-01

    A new programming method has been developed for grinding robots. Instead of using the conventional jog-and-teach method, the workpiece contour is automatically tracked by the robot. During the tracking, the robot position is stored in the robot control system every 8th millisecond. After filtering and reducing this contour data, a robot program is automatically generated.

  2. Some distinguishing characteristics of contour and texture phenomena in images

    Science.gov (United States)

    Jobson, Daniel J.

    1992-01-01

    The development of generalized contour/texture discrimination techniques is a central element necessary for machine vision recognition and interpretation of arbitrary images. Here, the visual perception of texture, selected studies of texture analysis in machine vision, and diverse small samples of contour and texture are all used to provide insights into the fundamental characteristics of contour and texture. From these, an experimental discrimination scheme is developed and tested on a battery of natural images. The visual perception of texture defined fine texture as a subclass which is interpreted as shading and is distinct from coarse figural similarity textures. Also, perception defined the smallest scale for contour/texture discrimination as eight to nine visual acuity units. Three contour/texture discrimination parameters were found to be moderately successful for this scale discrimination: (1) lightness change in a blurred version of the image, (2) change in lightness change in the original image, and (3) percent change in edge counts relative to local maximum.

  3. Ingenious Snake: An Adaptive Multi-Class Contours Extraction

    Science.gov (United States)

    Li, Baolin; Zhou, Shoujun

    2018-04-01

    Active contour model (ACM) plays an important role in computer vision and medical image application. The traditional ACMs were used to extract single-class of object contours. While, simultaneous extraction of multi-class of interesting contours (i.e., various contours with closed- or open-ended) have not been solved so far. Therefore, a novel ACM model named “Ingenious Snake” is proposed to adaptively extract these interesting contours. In the first place, the ridge-points are extracted based on the local phase measurement of gradient vector flow field; the consequential ridgelines initialization are automated with high speed. Secondly, the contours’ deformation and evolvement are implemented with the ingenious snake. In the experiments, the result from initialization, deformation and evolvement are compared with the existing methods. The quantitative evaluation of the structure extraction is satisfying with respect of effectiveness and accuracy.

  4. Foot placement modulation diminishes for perturbations near foot contact

    NARCIS (Netherlands)

    Vlutters, Mark; Van Asseldonk, Edwin H.F.; van der Kooij, Herman

    2018-01-01

    Whenever a perturbation occurs during walking we have to maintain our balance using the recovery strategies that are available to us. Foot placement adjustment is often considered an important recovery strategy. However, because this strategy takes time it is likely a poor option if the foot is

  5. Mortality associated with acute Charcot foot and neuropathic foot ulceration

    NARCIS (Netherlands)

    van Baal, Juliette; Hubbard, Richard; Game, Fran; Jeffcoate, William

    2010-01-01

    To compare the mortality of patients with an acute Charcot foot with a matched population with uninfected neuropathic foot ulcers (NFUs). Data were extracted from a specialist departmental database, supplemented by hospital records. The findings were compared with the results of earlier populations

  6. Effect of surface treatment of prefabricated teeth on shear bond strength of orthodontic brackets

    Directory of Open Access Journals (Sweden)

    Marina Cumerlato

    Full Text Available ABSTRACT Objective: The aim of this in vitro study was to evaluate and compare the effects of grinding, drilling, sandblasting, and ageing prefabricated teeth (PfT on the shear bond strength (SBS of orthodontic brackets, as well as the effects of surface treatments on the adhesive remnant index (ARI. Methods: One-hundred-ninety-two PfT were divided into four groups (n = 48: Group 1, no surface treatment was done; Group 2, grinding was performed with a cylindrical diamond bur; Group 3, two drillings were done with a spherical diamond bur; Group 4, sandblasting was performed with 50-µm aluminum oxide. Before the experiment, half of the samples stayed immersed in distilled water at 37oC for 90 days. Brackets were bonded with Transbond XT and shear strength tests were carried out using a universal testing machine. SBS were compared by surface treatment and by ageing with two-way ANOVA, followed by Tukey’s test. ARI scores were compared between surface treatments with Kruskal-Wallis test followed by Dunn’s test. Results: Surface treatments on PfT enhanced SBS of brackets (p< 0.01, result not observed with ageing (p= 0.45. Groups II, III, and IV showed higher SBS and greater ARI than the Group 1 (p< 0.05. SBS was greater in the groups 3 and 4 (drilling, sandblasting than in the Group 2 (grinding (p< 0.05. SBS and ARI showed a positive correlation (Spearman’s R2= 0.57; p< 0.05. Conclusion: Surface treatment on PfT enhanced SBS of brackets, however ageing did not show any relevance. Sandblasting and drilling showed greater SBS than grinding. There was a positive correlation between SBS and ARI.

  7. Particulate Matter Mass Concentration in Residential Prefabricated Buildings Related to Temperature and Moisture

    Science.gov (United States)

    Kraus, Michal; Juhásová Šenitková, Ingrid

    2017-10-01

    Building environmental audit and the assessment of indoor air quality (IAQ) in typical residential buildings is necessary process to ensure users’ health and well-being. The paper deals with the concentrations on indoor dust particles (PM10) in the context of hygrothermal microclimate in indoor environment. The indoor temperature, relative humidity and air movement are basic significant factors determining the PM10 concentration [μg/m3]. The experimental measurements in this contribution represent the impact of indoor physical parameters on the concentration of particulate matter mass concentration. The occurrence of dust particles is typical for the almost two-thirds of interiors of the buildings. Other parameters indoor environment, such as air change rate, volume of the room, roughness and porosity of the building material surfaces, static electricity, light ions and others, were set constant and they are not taken into account in this study. The mass concentration of PM10 is measured during summer season in apartment of residential prefabricated building. The values of global temperature [°C] and relative humidity of indoor air [%] are also monitored. The quantity of particulate mass matter is determined gravimetrically by weighing according to CSN EN 12 341 (2014). The obtained results show that the temperature difference of the internal environment does not have a significant effect on the concentration PM10. Vice versa, the difference of relative humidity exhibits a difference of the concentration of dust particles. Higher levels of indoor particulates are observed for low values of relative humidity. The decreasing of relative air humidity about 10% caused 10µg/m3 of PM10 concentration increasing. The hygienic limit value of PM10 concentration is not exceeded at any point of experimental measurement.

  8. Marginal Productivity Gained Through Prefabrication: Case Studies of Building Projects in Auckland

    Directory of Open Access Journals (Sweden)

    Wajiha Shahzad

    2015-02-01

    Full Text Available Several studies have documented benefits of prefabrication system (prefab compared to the traditional building system (TBS. However, the documented benefits have been anecdotal or fragmented with reports of isolated case study projects. Few studies have looked at the objectively quantified benefits from statistical significance point of view and across building types in New Zealand. This study contributes to filling this knowledge gap by analyzing cost and time-savings, and productivity improvement achievable by the use of prefab in place of the TBS. Records of completion times and final contract values of 66 building projects implemented using prefab in Auckland were collected. The building types included commercial, houses, apartments, educational, and community buildings. The project details included final contract sums, completion dates, gross floor areas, and number of floors. Based on these details, the equivalent completion times and the final cost estimates for similar buildings implemented using the TBS were obtained from the Rawlinsons construction data handbook and feedback from some designers and contractors. Marginal productivity outcome for each building project was computed as the product of the cost and time-savings achieved using the prefab. Results showed that the use of prefab in place of TBS resulted in 34% and 19% average reductions in the completion times and costs, respectively. This also translated to overall 7% average improvement in the productivity outcomes in the building projects. Univariate ANOVA-based hypothesis test results showed that ‘building type’ had no significant effects on the cost and productivity improvement outcomes, but had significant effect on the time savings analyzed in the case study projects. The greatest productivity gain of 11% was achieved in house projects. These evidence-based results could guide optimized use of prefab for specific building application. The hypothesis-testing outcome

  9. Effect of surface treatment of prefabricated teeth on shear bond strength of orthodontic brackets

    Science.gov (United States)

    Cumerlato, Marina; de Lima, Eduardo Martinelli; Osorio, Leandro Berni; Mota, Eduardo Gonçalves; de Menezes, Luciane Macedo; Rizzatto, Susana Maria Deon

    2017-01-01

    ABSTRACT Objective: The aim of this in vitro study was to evaluate and compare the effects of grinding, drilling, sandblasting, and ageing prefabricated teeth (PfT) on the shear bond strength (SBS) of orthodontic brackets, as well as the effects of surface treatments on the adhesive remnant index (ARI). Methods: One-hundred-ninety-two PfT were divided into four groups (n = 48): Group 1, no surface treatment was done; Group 2, grinding was performed with a cylindrical diamond bur; Group 3, two drillings were done with a spherical diamond bur; Group 4, sandblasting was performed with 50-µm aluminum oxide. Before the experiment, half of the samples stayed immersed in distilled water at 37oC for 90 days. Brackets were bonded with Transbond XT and shear strength tests were carried out using a universal testing machine. SBS were compared by surface treatment and by ageing with two-way ANOVA, followed by Tukey’s test. ARI scores were compared between surface treatments with Kruskal-Wallis test followed by Dunn’s test. Results: Surface treatments on PfT enhanced SBS of brackets (p< 0.01), result not observed with ageing (p= 0.45). Groups II, III, and IV showed higher SBS and greater ARI than the Group 1 (p< 0.05). SBS was greater in the groups 3 and 4 (drilling, sandblasting) than in the Group 2 (grinding) (p< 0.05). SBS and ARI showed a positive correlation (Spearman’s R2= 0.57; p< 0.05). Conclusion: Surface treatment on PfT enhanced SBS of brackets, however ageing did not show any relevance. Sandblasting and drilling showed greater SBS than grinding. There was a positive correlation between SBS and ARI. PMID:28902249

  10. Optical Character Recognition Using Active Contour Segmentation

    Directory of Open Access Journals (Sweden)

    Nabeel Oudah

    2018-01-01

    Full Text Available Document analysis of images snapped by camera is a growing challenge. These photos are often poor-quality compound images, composed of various objects and text; this makes automatic analysis complicated. OCR is one of the image processing techniques which is used to perform automatic identification of texts. Existing image processing techniques need to manage many parameters in order to clearly recognize the text in such pictures. Segmentation is regarded one of these essential parameters. This paper discusses the accuracy of segmentation process and its effect over the recognition process. According to the proposed method, the images were firstly filtered using the wiener filter then the active contour algorithm could be applied in the segmentation process. The Tesseract OCR Engine was selected in order to evaluate the performance and identification accuracy of the proposed method. The results showed that a more accurate segmentation process shall lead to a more accurate recognition results. The rate of recognition accuracy was 0.95 for the proposed algorithm compared with 0.85 for the Tesseract OCR Engine.

  11. Perception of illusory contour figures: Microgenetic analysis

    Directory of Open Access Journals (Sweden)

    Gvozdenović Vasilije P.

    2004-01-01

    Full Text Available Microgenetic analysis was used to investigate perception of illusory contour figures which represent whole, completed forms on the basis of segmented, incomplete stimulation. The analysis provided an experimental approach to this phenomenon which was standardly investigated phenomenologically. Experimental procedure consisted of two phases: a priming phase and b test phase which consisted of visual search task. Two types of visual search tasks were applied: (i classic detection, in which subjects were detecting presence or absence of the target stimuli and (ii two-alternative forced choice, 2AFC, in which subjects performed discrimination between two concurrent targets (target A vs. target B. Variation of exposition of prim stimuli was used as an indication of the percept formation period. Concepts like early vision, visual attention and feature binding were investigated. Four experiments were conducted. Their outcome showed that (i perception of amodal figure requires visual attention, (ii features binding precedes spatial attention and (iii time period of percept formation is dependent of task properties and varies between 50 - 150 ms. Some results obtained in this research could be explained by feature-integration theory (Treisman & Gelade, 1980; Treisman, 1986. Furthermore, percept formation period data comply with data acquired in Elliott & Müller's psychophysical research (1998.

  12. Ovate pontics: Phoenixing the gingival contour

    Directory of Open Access Journals (Sweden)

    Medha Vivek Bhuskute

    2017-01-01

    Full Text Available In today's busy world, most patients do not have time for long, drawn-out dental treatment. The time span between extraction and healing after loss of tooth in the anterior esthetic zone can be esthetically and psychologically devastating on the part of the patient. Especially, when a maxillary anterior tooth must be extracted and replaced, immediate tooth replacement with an ovate pontic on a provisional bridge is a good alternative. Ovate pontic helps in preservation of the interdental papilla, which in turn preserves the natural gingival contour that would have otherwise been lost after extraction. An immediate tooth replacement using ovate pontic not only eliminates the psychologically disturbing partially edentulous phase but also results in a much more esthetically pleasing replacement of tooth that is both hygienic and natural in appearance. Another added advantage of the use of ovate pontic is that it rules out the dissatisfaction resulting from an unesthetic ridge lap pontic placed directly over edentulous ridge. Just like the long-lived bird “Phoenix,” arising out of its own ashes, the ovate pontic creates an illusion that the pontic is emerging from the gingiva, even after tooth loss. This case report discusses how an integrated approach of fabricating heat cure provisional bridge with ovate pontics before extractions, benefitted a young patient in whom fractured anterior teeth were proposed for extraction.

  13. Contour tracing for segmentation of mammographic masses

    International Nuclear Information System (INIS)

    Elter, Matthias; Held, Christian; Wittenberg, Thomas

    2010-01-01

    CADx systems have the potential to support radiologists in the difficult task of discriminating benign and malignant mammographic lesions. The segmentation of mammographic masses from the background tissue is an important module of CADx systems designed for the characterization of mass lesions. In this work, a novel approach to this task is presented. The segmentation is performed by automatically tracing the mass' contour in-between manually provided landmark points defined on the mass' margin. The performance of the proposed approach is compared to the performance of implementations of three state-of-the-art approaches based on region growing and dynamic programming. For an unbiased comparison of the different segmentation approaches, optimal parameters are selected for each approach by means of tenfold cross-validation and a genetic algorithm. Furthermore, segmentation performance is evaluated on a dataset of ROI and ground-truth pairs. The proposed method outperforms the three state-of-the-art methods. The benchmark dataset will be made available with publication of this paper and will be the first publicly available benchmark dataset for mass segmentation.

  14. What is the diabetic foot?

    African Journals Online (AJOL)

    increase in the complications related to diabetes as a result of this increasing ... A number of contributory factors work together to cause foot ... neuropathy, peripheral vascular disease, foot deformities, external ... it is usually a combination of problems rather than a single risk ... This results in increased oxidative stress.

  15. Hand, Foot, and Mouth Disease

    Centers for Disease Control (CDC) Podcasts

    Hand, foot, and mouth disease is a contagious illness that mainly affects children under five. In this podcast, Dr. Eileen Schneider talks about the symptoms of hand, foot, and mouth disease, how it spreads, and ways to help protect yourself and your children from getting infected with the virus.

  16. Avoiding foot complications in diabetes

    African Journals Online (AJOL)

    preceded by a foot ulcer.1,2 Every 30 seconds a lower limb or part of a lower limb is ... of foot ulcers are peripheral neuropathy, deformity, peripheral vascular disease and ... Repetitive stresses cause hyperkeratosis, followed by subcutaneous ...

  17. Foot-and-mouth disease

    DEFF Research Database (Denmark)

    Belsham, Graham; Charleston, Bryan; Jackson, Terry

    2009-01-01

    Foot-and-mouth disease is an economically important, highly contagious, disease of cloven-hoofed animals characterized by the appearance of vesicles (blisters) on the feet and in and around the mouth. The causative agent, foot-and-mouth disease virus, was the first mammalian virus to be discovered...

  18. Spatial profile of contours inducing long-range color assimilation.

    Science.gov (United States)

    Devinck, Frédéric; Spillmann, Lothar; Werner, John S

    2006-01-01

    Color induction was measured using a matching method for two spatial patterns, each composed of double contours. In one pattern (the standard), the contours had sharp edges to induce the Watercolor Effect (WCE); in the other, the two contours had a spatial taper so that the overall profile produced a sawtooth edge, or ramped stimulus. These patterns were chosen based on our previous study demonstrating that the strength of the chromatic WCE depends on a luminance difference between the two contours. Low-pass chromatic mechanisms, unlike bandpass luminance mechanisms, may be expected to be insensitive to the difference between the two spatial profiles. The strength of the watercolor spreading was similar for the two patterns at narrow widths of the contour possibly because of chromatic aberration, but with wider contours, the standard stimulus produced stronger assimilation than the ramped stimulus. This research suggests that luminance-dependent chromatic mechanisms mediate the WCE and that these mechanisms are sensitive to differences in the two spatial profiles of the pattern contours only when they are wide.

  19. GPU based contouring method on grid DEM data

    Science.gov (United States)

    Tan, Liheng; Wan, Gang; Li, Feng; Chen, Xiaohui; Du, Wenlong

    2017-08-01

    This paper presents a novel method to generate contour lines from grid DEM data based on the programmable GPU pipeline. The previous contouring approaches often use CPU to construct a finite element mesh from the raw DEM data, and then extract contour segments from the elements. They also need a tracing or sorting strategy to generate the final continuous contours. These approaches can be heavily CPU-costing and time-consuming. Meanwhile the generated contours would be unsmooth if the raw data is sparsely distributed. Unlike the CPU approaches, we employ the GPU's vertex shader to generate a triangular mesh with arbitrary user-defined density, in which the height of each vertex is calculated through a third-order Cardinal spline function. Then in the same frame, segments are extracted from the triangles by the geometry shader, and translated to the CPU-side with an internal order in the GPU's transform feedback stage. Finally we propose a "Grid Sorting" algorithm to achieve the continuous contour lines by travelling the segments only once. Our method makes use of multiple stages of GPU pipeline for computation, which can generate smooth contour lines, and is significantly faster than the previous CPU approaches. The algorithm can be easily implemented with OpenGL 3.3 API or higher on consumer-level PCs.

  20. A Biologically Motivated Multiresolution Approach to Contour Detection

    Directory of Open Access Journals (Sweden)

    Alessandro Neri

    2007-01-01

    Full Text Available Standard edge detectors react to all local luminance changes, irrespective of whether they are due to the contours of the objects represented in a scene or due to natural textures like grass, foliage, water, and so forth. Moreover, edges due to texture are often stronger than edges due to object contours. This implies that further processing is needed to discriminate object contours from texture edges. In this paper, we propose a biologically motivated multiresolution contour detection method using Bayesian denoising and a surround inhibition technique. Specifically, the proposed approach deploys computation of the gradient at different resolutions, followed by Bayesian denoising of the edge image. Then, a biologically motivated surround inhibition step is applied in order to suppress edges that are due to texture. We propose an improvement of the surround suppression used in previous works. Finally, a contour-oriented binarization algorithm is used, relying on the observation that object contours lead to long connected components rather than to short rods obtained from textures. Experimental results show that our contour detection method outperforms standard edge detectors as well as other methods that deploy inhibition.

  1. Low level constraints on dynamic contour path integration.

    Directory of Open Access Journals (Sweden)

    Sophie Hall

    Full Text Available Contour integration is a fundamental visual process. The constraints on integrating discrete contour elements and the associated neural mechanisms have typically been investigated using static contour paths. However, in our dynamic natural environment objects and scenes vary over space and time. With the aim of investigating the parameters affecting spatiotemporal contour path integration, we measured human contrast detection performance of a briefly presented foveal target embedded in dynamic collinear stimulus sequences (comprising five short 'predictor' bars appearing consecutively towards the fovea, followed by the 'target' bar in four experiments. The data showed that participants' target detection performance was relatively unchanged when individual contour elements were separated by up to 2° spatial gap or 200 ms temporal gap. Randomising the luminance contrast or colour of the predictors, on the other hand, had similar detrimental effect on grouping dynamic contour path and subsequent target detection performance. Randomising the orientation of the predictors reduced target detection performance greater than introducing misalignment relative to the contour path. The results suggest that the visual system integrates dynamic path elements to bias target detection even when the continuity of path is disrupted in terms of spatial (2°, temporal (200 ms, colour (over 10 colours and luminance (-25% to 25% information. We discuss how the findings can be largely reconciled within the functioning of V1 horizontal connections.

  2. Use of dry sludge from waste water treatment plants as an additive in prefabricated concrete brick

    Directory of Open Access Journals (Sweden)

    Yagüe, A.

    2002-09-01

    Full Text Available Dry sludge from the Sabadell Water Treatment Plant was used to prepare prefabricated concrete bricks. After characterising the sludge and the manufacturing process used to make the bricks, we define the conditions of addition of the sludges in the manufacture. Reference samples not containing sludge and samples containing 2 % of dry sludge by cement weight were prepared. The variation in density, porosity, absorption coefficient and compressive strength of the bricks with the presence of sludge was determined over time. Leaching of the bricks was determined according to the NEN 7345 standard. In most cases the addition of sludge produces a decrease in porosity and absorption coefficients and an increase in compressive strength, so one could expect these bricks to have greater durability. As regards leaching pollutants in the bricks, they are below the limit of the Dutch NEN standard for construction materials and thus can be classified as inert material.

    El estudio ha consistido en la utilización de lodo seco de origen biológico de la depuradora de aguas residuales de Sabadell (Riu Sec, como adición en la preparación de adoquines de hormigón prefabricado. Después de caracterizar los lodos y el proceso de fabricación de los adoquines que utilizaremos, definimos las condiciones de adición de los lodos en esta fabricación. Se prepararon muestras de referencia, sin adición, y muestras con el 2 % de lodo seco sobrepeso de cemento. Se determinaron cómo variaban en el tiempo, con la presencia de lodos: la densidad, la porosidad y el coeficiente de absorción, y la resistencia mecánica a compresión de los adoquines. También se determinó la lixiviación que estas piezas presentaban de acuerdo a la norma NEN 7345. La adición de lodos produce, en la mayoría de los casos, una disminución de las porosidades y de los coeficientes de absorción y un aumento en las resistencias mecánicas, por lo que cabe esperar una mayor

  3. Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment

    Directory of Open Access Journals (Sweden)

    Rudys Rodolfo de Jesus Tavarez

    2011-02-01

    Full Text Available OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10 of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm at the implant/abutment interface was evaluated before (B and after (A application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey's post-hoc test (p<0.05. RESULTS: Before loading values showed no difference among groups 2 (4.33±3.13, 3 (4.79±3.43 and 5 (3.86±4.60; between groups 1 (12.88±6.43 and 4 (9.67±3.08, and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77 and 4 (17.78±10.99 were significantly different from those of groups 2 (4.83±4.50, 3 (8.07±4.31 and 5 (3.81±4.84. There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. CONCLUSIONS: The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface.

  4. Large Prefabricated Concrete Panels Collective Dwellings from the 1970s: Context and Improvements

    Science.gov (United States)

    Muntean, Daniel M.; Ungureanu, Viorel; Petran, Ioan; Georgescu, Mircea

    2017-10-01

    The period between 1960s and 1970s had a significant impact in Romania on the urban development of major cities. Because the vast expansion of the industry, the urban population has massively increased, due the large number of workers coming from the rural areas. This intense process has led to a shortage of homes on the housing market. In order to rapidly build new homes, standard residential project types were erected using large prefabricated concrete panels. By using repetitive patterns, such buildings were built in a short amount of time through the entire country. Nowadays, these buildings represent 1.8% of the built environment and accommodate more than half of a city’s population. Even though these units have reached only half their intended life span, they fail to satisfy present living standards and consume huge amounts of energy for heating, cooling, ventilation and lighting. Due to the fact that these building are based on standardised projects and were built in such a large scale, the creation of a system that brings them to current standards will not only benefit the building but also it will significantly improve the quality of life within. With the transition of the existing power grids to a “smart grid” such units can become micro power plants in future electricity networks thus contributing to micro-generation and energy storage. If one is to consider the EU 20-20-20 commitments, to find ideas for alternative and innovative strategies for further improving these building through locally adapted measures can be seen as one of the most addressed issues of today. This research offers a possible retrofitting scenario of these buildings towards a sustainable future. The building envelope is upgraded using a modular insulation system with integrated solar cells. Renewable energy systems for cooling and ventilation are integrated in order to provide flexibility of the indoor climate. Due to their small floor area, the space within the apartments is

  5. Shape reconstruction from apparent contours theory and algorithms

    CERN Document Server

    Bellettini, Giovanni; Paolini, Maurizio

    2015-01-01

    Motivated by a variational model concerning the depth of the objects in a picture and the problem of hidden and illusory contours, this book investigates one of the central problems of computer vision: the topological and algorithmic reconstruction of a smooth three dimensional scene starting from the visible part of an apparent contour. The authors focus their attention on the manipulation of apparent contours using a finite set of elementary moves, which correspond to diffeomorphic deformations of three dimensional scenes. A large part of the book is devoted to the algorithmic part, with implementations, experiments, and computed examples. The book is intended also as a user's guide to the software code appcontour, written for the manipulation of apparent contours and their invariants. This book is addressed to theoretical and applied scientists working in the field of mathematical models of image segmentation.

  6. MAP Estimation of Chin and Cheek Contours in Video Sequences

    Directory of Open Access Journals (Sweden)

    Kampmann Markus

    2004-01-01

    Full Text Available An algorithm for the estimation of chin and cheek contours in video sequences is proposed. This algorithm exploits a priori knowledge about shape and position of chin and cheek contours in images. Exploiting knowledge about the shape, a parametric 2D model representing chin and cheek contours is introduced. Exploiting knowledge about the position, a MAP estimator is developed taking into account the observed luminance gradient as well as a priori probabilities of chin and cheek contours positions. The proposed algorithm was tested with head and shoulder video sequences (image resolution CIF. In nearly 70% of all investigated video frames, a subjectively error free estimation could be achieved. The 2D estimate error is measured as on average between 2.4 and .

  7. Characterizing multisegment foot kinematics during gait in diabetic foot patients

    Directory of Open Access Journals (Sweden)

    Denti Paolo

    2009-10-01

    Full Text Available Abstract Background The prevalence of diabetes mellitus has reached epidemic proportions, this condition may result in multiple and chronic invalidating long term complications. Among these, the diabetic foot, is determined by the simultaneous presence of both peripheral neuropathy and vasculopathy that alter the biomechanics of the foot with the formation of callosity and ulcerations. To diagnose and treat the diabetic foot is crucial to understand the foot complex kinematics. Most of gait analysis protocols represent the entire foot as a rigid body connected to the shank. Nevertheless the existing multisegment models cannot completely decipher the impairments associated with the diabetic foot. Methods A four segment foot and ankle model for assessing the kinematics of the diabetic foot was developed. Ten normal subjects and 10 diabetics gait patterns were collected and major sources of variability were tested. Repeatability analysis was performed both on a normal and on a diabetic subject. Direct skin marker placement was chosen in correspondence of 13 anatomical landmarks and an optoelectronic system was used to collect the data. Results Joint rotation normative bands (mean plus/minus one standard deviation were generated using the data of the control group. Three representative strides per subject were selected. The repeatability analysis on normal and pathological subjects results have been compared with literature and found comparable. Normal and pathological gait have been compared and showed major statistically significant differences in the forefoot and midfoot dorsi-plantarflexion. Conclusion Even though various biomechanical models have been developed so far to study the properties and behaviour of the foot, the present study focuses on developing a methodology for the functional assessment of the foot-ankle complex and for the definition of a functional model of the diabetic neuropathic foot. It is, of course, important to evaluate

  8. Combined diabetic foot infections treatment, complicated by foot phlegmon

    Directory of Open Access Journals (Sweden)

    Yavruyan O.A.

    2017-01-01

    Full Text Available the article shows the analysis of treatment results of 163 patients with diabetic foot infections, complicated by foot phlegmon. Patients were divided into 2 groups. The control group received traditional treatment and had an autopsy deep plantar space done and then, during the second phase, cytokine-rich autoplatelet concentrate had been applied. The research results confirmed a significant decrease in the duration of treatment and hospitalization of patients in the hospital.

  9. Auto-propagation of contours for adaptive prostate radiation therapy

    International Nuclear Information System (INIS)

    Chao Ming; Xie Yaoqin; Xing Lei

    2008-01-01

    The purpose of this work is to develop an effective technique to automatically propagate contours from planning CT to cone beam CT (CBCT) to facilitate CBCT-guided prostate adaptive radiation therapy. Different from other disease sites, such as the lungs, the contour mapping here is complicated by two factors: (i) the physical one-to-one correspondence may not exist due to the insertion or removal of some image contents within the region of interest (ROI); and (ii) reduced contrast to noise ratio of the CBCT images due to increased scatter. To overcome these issues, we investigate a strategy of excluding the regions with variable contents by a careful design of a narrow shell signifying the contour of an ROI. For rectum, for example, a narrow shell with the delineated contours as its interior surface was constructed to avoid the adverse influence of the day-to-day content change inside the rectum on the contour mapping. The corresponding contours in the CBCT were found by warping the narrow shell through the use of BSpline deformable model. Both digital phantom experiments and clinical case testing were carried out to validate the proposed ROI mapping method. It was found that the approach was able to reliably warp the constructed narrow band with an accuracy better than 1.3 mm. For all five clinical cases enrolled in this study, the method yielded satisfactory results even when there were significant rectal content changes between the planning CT and CBCT scans. The overlapped area of the auto-mapped contours over 90% to the manually drawn contours is readily achievable. The proposed approach permits us to take advantage of the regional calculation algorithm yet avoiding the nuisance of rectum/bladder filling and provide a useful tool for adaptive radiotherapy of prostate in the future

  10. Auto-propagation of contours for adaptive prostate radiation therapy

    Science.gov (United States)

    Chao, Ming; Xie, Yaoqin; Xing, Lei

    2008-09-01

    The purpose of this work is to develop an effective technique to automatically propagate contours from planning CT to cone beam CT (CBCT) to facilitate CBCT-guided prostate adaptive radiation therapy. Different from other disease sites, such as the lungs, the contour mapping here is complicated by two factors: (i) the physical one-to-one correspondence may not exist due to the insertion or removal of some image contents within the region of interest (ROI); and (ii) reduced contrast to noise ratio of the CBCT images due to increased scatter. To overcome these issues, we investigate a strategy of excluding the regions with variable contents by a careful design of a narrow shell signifying the contour of an ROI. For rectum, for example, a narrow shell with the delineated contours as its interior surface was constructed to avoid the adverse influence of the day-to-day content change inside the rectum on the contour mapping. The corresponding contours in the CBCT were found by warping the narrow shell through the use of BSpline deformable model. Both digital phantom experiments and clinical case testing were carried out to validate the proposed ROI mapping method. It was found that the approach was able to reliably warp the constructed narrow band with an accuracy better than 1.3 mm. For all five clinical cases enrolled in this study, the method yielded satisfactory results even when there were significant rectal content changes between the planning CT and CBCT scans. The overlapped area of the auto-mapped contours over 90% to the manually drawn contours is readily achievable. The proposed approach permits us to take advantage of the regional calculation algorithm yet avoiding the nuisance of rectum/bladder filling and provide a useful tool for adaptive radiotherapy of prostate in the future.

  11. Auto-propagation of contours for adaptive prostate radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Chao Ming; Xie Yaoqin; Xing Lei [Department of Radiation Oncology, Stanford University School of Medicine, 875 Blake Wilbur Drive, Stanford, CA 94305-5847 (United States)], E-mail: lei@reyes.stanford.edu

    2008-09-07

    The purpose of this work is to develop an effective technique to automatically propagate contours from planning CT to cone beam CT (CBCT) to facilitate CBCT-guided prostate adaptive radiation therapy. Different from other disease sites, such as the lungs, the contour mapping here is complicated by two factors: (i) the physical one-to-one correspondence may not exist due to the insertion or removal of some image contents within the region of interest (ROI); and (ii) reduced contrast to noise ratio of the CBCT images due to increased scatter. To overcome these issues, we investigate a strategy of excluding the regions with variable contents by a careful design of a narrow shell signifying the contour of an ROI. For rectum, for example, a narrow shell with the delineated contours as its interior surface was constructed to avoid the adverse influence of the day-to-day content change inside the rectum on the contour mapping. The corresponding contours in the CBCT were found by warping the narrow shell through the use of BSpline deformable model. Both digital phantom experiments and clinical case testing were carried out to validate the proposed ROI mapping method. It was found that the approach was able to reliably warp the constructed narrow band with an accuracy better than 1.3 mm. For all five clinical cases enrolled in this study, the method yielded satisfactory results even when there were significant rectal content changes between the planning CT and CBCT scans. The overlapped area of the auto-mapped contours over 90% to the manually drawn contours is readily achievable. The proposed approach permits us to take advantage of the regional calculation algorithm yet avoiding the nuisance of rectum/bladder filling and provide a useful tool for adaptive radiotherapy of prostate in the future.

  12. A historical note on illusory contours in shadow writing.

    Science.gov (United States)

    Vezzani, Stefano; Marino, Barbara F M

    2009-01-01

    It is widely accepted that illusory contours have been first displayed and discussed by Schumann (1900, Zeitschrift für Psychologie und Physiologie der Sinnesorgane 23 1-32). Here we show that, before him, Jastrow (1899, Popular Science Monthly 54 299-312) produced illusory contours consisting of a shadow word. A brief history of shadow writing in psychological literature from Jastrow to Brunswik is presented, in which the contributions of Pillsbury, Warren, Koffka, and Benussi are examined.

  13. Preservation of keratinized mucosa around implants using a prefabricated implant-retained stent: a case-control study

    Science.gov (United States)

    2016-01-01

    Purpose The aim of this study was to clinically assess the impact of a prefabricated implant-retained stent clipped over healing abutments on the preservation of keratinized mucosa around implants after implant surgery, and to compare it with horizontal external mattress sutures. Methods A total of 50 patients were enrolled in this study. In the test group, a prefabricated implant-retained stent was clipped on the healing abutment after implant surgery to replace the keratinized tissue bucco-apically. In the control group, horizontal external mattress sutures were applied instead of using a stent. After the surgical procedure, the width of the buccal keratinized mucosa was measured at the mesial, middle, and distal aspects of the healing abutment. The change in the width of the buccal keratinized mucosa was assessed at 1 and 3 months. Results Healing was uneventful in both groups. The difference of width between baseline and 1 month was −0.26±0.85 mm in the test group, without any statistical significance (P=0.137). Meanwhile, the corresponding difference in the control group was −0.74±0.73 mm and it showed statistical significance (Pprefabricated implant-retained stent was shown to be effective in the preservation of the keratinized mucosa around implants and it was simple and straightforward in comparison to the horizontal external mattress suture technique. PMID:27800215

  14. The effects of local nitroglycerin on the surgical delay procedure in prefabricated flaps by vascular implant in rats.

    Science.gov (United States)

    Sá, Jairo Zacchê de; Aguiar, José Lamartine de Andrade; Cruz, Adriana Ferreira; Schuler, Alexandre Ricardo Pereira; Lima, José Ricardo Alves de; Marques, Olga Martins

    2012-12-01

    To evaluate the effect of local nitroglycerin on the viable area of a prefabricated flap for vascular implant in rats, and to investigate the surgical delay procedure. A femoral pedicle was implanted under the skin of the abdominal wall in forty Wistar rats. The animals were divided into four groups of ten: group 1 - without surgical delay procedure and local nitroglycerin; group 2 - with surgical delay procedure, but without local nitroglycerin; group 3 - without surgical delay procedure, but with local nitroglycerin; and group 4 - with simultaneous surgical delay procedure and local nitroglycerin. The percentages of the viable areas, in relation to the total flap, were calculated using AutoCAD R 14. The mean percentage value of the viable area was 8.9% in the group 1. 49.4% in the group 2; 8.4% in the group 3 and 1.1% in the group 4. There was significant difference between groups 1 and 2 (p=0.005), 1 and 4 (p=0.024), 2 and 3 (p=0.003), 2 and 4 (p=0.001). These results support the hypothesis that the closure of the arterial venous channels is responsible for the phenomenon of surgical delay procedure. Local nitroglycerin did not cause an increase in the prefabricated viable flap area by vascular implantation and decreased the viable flap area that underwent delay procedures.

  15. The effect of foot orthoses with forefoot cushioning or metatarsal pad on forefoot peak plantar pressure in running

    Directory of Open Access Journals (Sweden)

    Michaela Hähni

    2016-11-01

    Full Text Available Abstract Background Foot orthoses are frequently used in sports for the treatment of overuse complaints with sufficient evidence available for certain foot-related overuse pathologies like plantar fasciitis, rheumatoid arthritis and foot pain (e.g., metatarsalgia. One important aim is to reduce plantar pressure under prominent areas like metatarsal heads. For the forefoot region, mainly two common strategies exist: metatarsal pad (MP and forefoot cushioning (FC. The aim of this study was to evaluate which of these orthosis concepts is superior in reducing plantar pressure in the forefoot during running. Methods Twenty-three (13 female, 10 male asymptomatic runners participated in this cross-sectional experimental trial. Participants ran in a randomised order under the two experimental (MP, FC conditions and a control (C condition on a treadmill (2.78 ms−1 for 2 min, respectively. Plantar pressure was measured with the in-shoe plantar pressure measurement device pedar-x®-System and mean peak pressure averaged from ten steps in the forefoot (primary outcome and total foot was analysed. Insole comfort was measured with the Insole Comfort Index (ICI, sum score 0–100 after each running trial. The primary outcome was tested using the Friedman test (α = 0.05. Secondary outcomes were analysed descriptively (mean ± SD, lower & upper 95%-CI, median and interquartile-range (IQR. Results Peak pressure [kPa] in the forefoot was significantly lower wearing FC (281 ± 80, 95%-CI: 246–315 compared to both C (313 ± 69, 95%-CI: 283–343; p = .003 and MP (315 ± 80, 95%-CI: 280–350; p = .001. No significant difference was found between C and MP (p = .858. Peak pressures under the total foot were: C: 364 ± 82, 95%-CI: 328–399; MP: 357 ± 80, 95%-CI: 326–387; FC: 333 ± 81 95%-CI: 298–368. Median ICI sum scores were: C 50, MP 49, FC 64. Conclusions In contrast to the metatarsal pad orthosis, the

  16. Visual search of illusory contours: Shape and orientation effects

    Directory of Open Access Journals (Sweden)

    Gvozdenović Vasilije

    2008-01-01

    Full Text Available Illusory contours are specific class of visual stimuli that represent stimuli configurations perceived as integral irrespective of the fact that they are given in fragmented uncompleted wholes. Due to their specific features, illusory contours gained much attention in last decade representing prototype of stimuli used in investigations focused on binding problem. On the other side, investigations of illusory contours are related to problem of the level of their visual processing. Neurophysiologic studies show that processing of illusory contours proceed relatively early, on the V2 level, on the other hand most of experimental studies claim that illusory contours are perceived with engagement of visual attention, binding their elements to whole percept. This research is focused on two experiments in which visual search of illusory contours are based on shape and orientation. The main experimental procedure evolved the task proposed by Bravo and Nakayama where instead of detection, subjects were performing identification of one among two possible targets. In the first experiment subjects detected the presence of illusory square or illusory triangle, while in the second experiment subject were detecting two different orientations of illusory triangle. The results are interpreted in terms of visual search and feature integration theory. Beside the type of visual search task, search type proved to be dependent of specific features of illusory shapes which further complicate theoretical interpretation of the level of their perception.

  17. Contour junctions defined by dynamic image deformations enhance perceptual transparency.

    Science.gov (United States)

    Kawabe, Takahiro; Nishida, Shin'ya

    2017-11-01

    The majority of work on the perception of transparency has focused on static images with luminance-defined contour junctions, but recent work has shown that dynamic image sequences with dynamic image deformations also provide information about transparency. The present study demonstrates that when part of a static image is dynamically deformed, contour junctions at which deforming and nondeforming contours are connected facilitate the deformation-based perception of a transparent layer. We found that the impression of a transparent layer was stronger when a dynamically deforming area was adjacent to static nondeforming areas than when presented alone. When contour junctions were not formed at the dynamic-static boundaries, however, the impression of a transparent layer was not facilitated by the presence of static surrounding areas. The effect of the deformation-defined junctions was attenuated when the spatial pattern of luminance contrast at the junctions was inconsistent with the perceived transparency related to luminance contrast, while the effect did not change when the spatial luminance pattern was consistent with it. In addition, the results showed that contour completions across the junctions were required for the perception of a transparent layer. These results indicate that deformation-defined junctions that involve contour completion between deforming and nondeforming regions enhance the perception of a transparent layer, and that the deformation-based perceptual transparency can be promoted by the simultaneous presence of appropriately configured luminance and contrast-other features that can also by themselves produce the sensation of perceiving transparency.

  18. Summing over Feynman histories by functional contour integration

    International Nuclear Information System (INIS)

    Garrison, J.C.; Wright, E.M.

    1986-01-01

    The authors show how complex paths can be consistently introduced into sums for Feynman histories by using the notion of functional contour integration. For a kappa-dimensional system specified by a potential with suitable analyticity properties, each coordinate axis is replaced by a copy of the complex plane, and at each instant of time a contour is chosen in each plane. This map from the time axis into the set of complex contours defines a functional contour. The family of contours labelled by time generates a (kappa+1)-dimensional submanifold of the (2kappa+1)-dimensional space defined by the cartesian product of the time axis and the coordinate planes. The complex Feynman paths lie on this submanifold. An application of this idea to systems described by absorptive potentials yields a simple derivation of the correct WKB result in terms of a complex path that extremalises the action. The method can also be applied to spherically symmetric potentials by using a partial wave expansion and restricting the contours appropriately. (author)

  19. Priorities in offloading the diabetic foot

    NARCIS (Netherlands)

    Bus, Sicco A.

    2012-01-01

    Biomechanical factors play an important role in diabetic foot disease. Reducing high foot pressures (i.e. offloading) is one of the main goals in healing and preventing foot ulceration. Evidence-based guidelines show the strong association between the efficacy to offload the foot and clinical

  20. Imaging the diabetic foot

    International Nuclear Information System (INIS)

    Gold, R.H.; Tong, D.T.F.; Crim, J.R.; Seeger, L.L.

    1995-01-01

    Early and accurate diagnosis of infection or neuropathy of the diabetic foot is the key to successful management. Angiopathy leads to ischemia which, in combination with peripheral neuropathy, predisposes to pedal skin ulceration, the precursor of osteomyelitis. Chronic hyperglycemia promotes production of glycosylated end products which accumulate on endothelial proteins, causing ischemia of the vasa nervorum. When combined with axonal degeneration of the sensory nerves, the result is hypertrophic neuroarthropathy. Should the sympathetic nerve fibers also be damaged, the resultant loss of vasoconstrictive impulses leads to hyperemia and atrophic neuroarthropathy. Plain radiography, although less sensitive than radionuclide, magnetic resonance (MR), and computed tomographic examinations, should be the initial procedure for imaging suspected osteomyelitis in the diabetic patient. If the radiographs are normal but the clinical suspicion of osteomyelitis is strong, a three-phase 99m Tc-MDP scan or MR imaging is recommended. An equivocal 99m Tc-MDP scan should be followed by MR imaging. To exclude osteomyelitis at a site of neuroarthropathy, a 111 In white blood cell scan is preferable. To obtain a specimen of bone for bacteriological studies, percutaneous core biopsy is the procedure of choice, with the entrance of the needle well beyond the edge of the subjacent ulcer. (orig.)

  1. Imaging the diabetic foot

    Energy Technology Data Exchange (ETDEWEB)

    Gold, R.H. [Dept. of Radiological Sciences, UCLA School of Medicine, Los Angeles, CA (United States); Tong, D.T.F. [Dept. of Radiological Sciences, UCLA School of Medicine, Los Angeles, CA (United States); Crim, J.R. [Durham Radiology Associates, Durham, NC (United States); Seeger, L.L. [Dept. of Radiological Sciences, UCLA School of Medicine, Los Angeles, CA (United States)

    1995-11-01

    Early and accurate diagnosis of infection or neuropathy of the diabetic foot is the key to successful management. Angiopathy leads to ischemia which, in combination with peripheral neuropathy, predisposes to pedal skin ulceration, the precursor of osteomyelitis. Chronic hyperglycemia promotes production of glycosylated end products which accumulate on endothelial proteins, causing ischemia of the vasa nervorum. When combined with axonal degeneration of the sensory nerves, the result is hypertrophic neuroarthropathy. Should the sympathetic nerve fibers also be damaged, the resultant loss of vasoconstrictive impulses leads to hyperemia and atrophic neuroarthropathy. Plain radiography, although less sensitive than radionuclide, magnetic resonance (MR), and computed tomographic examinations, should be the initial procedure for imaging suspected osteomyelitis in the diabetic patient. If the radiographs are normal but the clinical suspicion of osteomyelitis is strong, a three-phase {sup 99m}Tc-MDP scan or MR imaging is recommended. An equivocal {sup 99m}Tc-MDP scan should be followed by MR imaging. To exclude osteomyelitis at a site of neuroarthropathy, a {sup 111}In white blood cell scan is preferable. To obtain a specimen of bone for bacteriological studies, percutaneous core biopsy is the procedure of choice, with the entrance of the needle well beyond the edge of the subjacent ulcer. (orig.)

  2. Hand, Foot, and Mouth Disease

    Centers for Disease Control (CDC) Podcasts

    2013-08-08

    Hand, foot, and mouth disease is a contagious illness that mainly affects children under five. In this podcast, Dr. Eileen Schneider talks about the symptoms of hand, foot, and mouth disease, how it spreads, and ways to help protect yourself and your children from getting infected with the virus.  Created: 8/8/2013 by National Center for Immunization and Respiratory Diseases (NCIRD).   Date Released: 8/8/2013.

  3. Poor compliance with ankle-foot-orthoses in Charcot-Marie-Tooth disease.

    Science.gov (United States)

    Vinci, P; Gargiulo, P

    2008-03-01

    The aim of this study is to evaluate the compliance with ankle-foot orthoses (AFOs) in patients previously prescribed and affected with Charcot-Marie-Tooth disease (CMT). Twenty-five Italian patients (8 males 17 females; mean age: 41.6 years, range 16-54) with severe bilateral footdrop (leg-sole angle alpha >105 degrees ) alone or associated with other problems (rotation, plantarflexor failure, knee flexor failure) were examined by a physiatrist (with measurement of the leg-sole angle alpha' with their footwear) and interviewed by a psychologist. Only 5 patients (20%) used AFOs (3 prefabricated polypropylene AFOs, 2 custom-made short AFOs incorporated in high-top boots) with satisfactory functional results (alpha' <=94 degrees ; reported increased mobility and no more falls). The interview revealed that all patients had a bad relationship with their own body. The 3 subjects using prefabricated AFOs said that they hated them and one of them complained of pain. Patients not using AFOs justified their decision with statements such as: ''I am not yet ready to accept them'' (n=3) or ''I can still manage without them for a while'' (n=2) or both (n=15). Four patients had experienced pain during the trial, 2 had not found proper shoes to accommodate them and 12 were absolutely not interested in AFOs and, therefore, had not gone to an orthotist. Compliance with AFOs is poor. Patients with CMT discard AFOs because they highlight their disability, are not essential for their limited daily walking and are uncomfortable. We suggest that prescription of AFOs be accompanied with psychological support and that research of more comfortable and cosmetically acceptable solutions for the problem of footdrop be stimulated.

  4. Brightness/darkness induction and the genesis of a contour

    Directory of Open Access Journals (Sweden)

    Sergio eRoncato

    2014-10-01

    Full Text Available Visual contours often result from the integration or interpolation of fragmented edges.The strength of the completion increases when the edges share the same contrast polarity (CP. Here we demonstrate that the appearance in the perceptual field of this integrated unit, or contour of invariant CP, is concomitant with a vivid brightness alteration of the surfaces at its opposite sides. To observe this effect requires some stratagems because the formation in the visual field of a contour of invariant CP normally engenders the formation of a second contour and then the rise of two streams of induction signals that interfere in different ways. Particular configurations have been introduced that allow us to observe the induction effects of one contour taken in isolation. I documented these effects by phenomenological observations and psychophysical measurement of the brightness alteration in relation to luminance contrast. When the edges of the same CP complete to form a contour, the background of homogeneous luminance appears to dim at one side and to brighten at the opposite side (in accord with the CP. The strength of the phenomenon is proportional to the local luminance contrast. This effect weakens or nulls when the contour of the invariant CP separates surfaces filled with different grey shades.These conflicting results stimulate a deeper exploration of the induction phenomena and their role in the computation of brightness contrast. An alternative perspective is offered to account for some brightness illusions and their relation to the phenomenal transparency. The main assumption asserts that, when in the same region induction signals of opposite CP overlap, the filling-in are blocked unless the image is stratified into different layers, one for each signal of the same polarity. Phenomenological observations document this solution by the visual system

  5. Towards a more common use of Ultra-High Performance Concrete (UHPC) – development of UHPC for ready-mix and prefabrication concrete plants

    NARCIS (Netherlands)

    Spiesz, P.R.; Hunger, M.; Justnes, Harald; Braarud, Henny

    2017-01-01

    This study addresses the development of ultra-high performance concrete (UHPC) suitable for a mass production in conventional ready-mix and prefabrication concrete plants. In order to facilitate the production process, curing regime and to minimize the costs, no additional treatments (e.g. thermal

  6. A new template matching method based on contour information

    Science.gov (United States)

    Cai, Huiying; Zhu, Feng; Wu, Qingxiao; Li, Sicong

    2014-11-01

    Template matching is a significant approach in machine vision due to its effectiveness and robustness. However, most of the template matching methods are so time consuming that they can't be used to many real time applications. The closed contour matching method is a popular kind of template matching methods. This paper presents a new closed contour template matching method which is suitable for two dimensional objects. Coarse-to-fine searching strategy is used to improve the matching efficiency and a partial computation elimination scheme is proposed to further speed up the searching process. The method consists of offline model construction and online matching. In the process of model construction, triples and distance image are obtained from the template image. A certain number of triples which are composed by three points are created from the contour information that is extracted from the template image. The rule to select the three points is that the template contour is divided equally into three parts by these points. The distance image is obtained here by distance transform. Each point on the distance image represents the nearest distance between current point and the points on the template contour. During the process of matching, triples of the searching image are created with the same rule as the triples of the model. Through the similarity that is invariant to rotation, translation and scaling between triangles, the triples corresponding to the triples of the model are found. Then we can obtain the initial RST (rotation, translation and scaling) parameters mapping the searching contour to the template contour. In order to speed up the searching process, the points on the searching contour are sampled to reduce the number of the triples. To verify the RST parameters, the searching contour is projected into the distance image, and the mean distance can be computed rapidly by simple operations of addition and multiplication. In the fine searching process

  7. After massive weight loss: patients' expectations of body contouring surgery.

    Science.gov (United States)

    Kitzinger, Hugo B; Abayev, Sara; Pittermann, Anna; Karle, Birgit; Bohdjalian, Arthur; Langer, Felix B; Prager, Gerhard; Frey, Manfred

    2012-04-01

    Massive weight loss following bariatric surgery leads to excess skin with functional and aesthetic impairments. Surplus skin can then contribute to problems with additional weight loss or gain. The aims of the current study were to evaluate the frequency of massive soft tissue development in gastric bypass patients, to determine whether males and females experience similar post-bypass body changes, and to learn about the expectations and impairments related to body contouring surgery. A questionnaire addressing information on the satisfaction of body image, quality of life, and expectation of body contouring surgery following massive weight loss was mailed to 425 patients who had undergone gastric bypass surgery between 2003 and 2009. Of these 425 individuals, 252 (59%) patients completed the survey. Ninety percent of women and 88% of men surveyed rated their appearance following massive weight loss as satisfactory, good, or very good. However, 96% of all patients developed surplus skin, which caused intertriginous dermatitis and itching. In addition, patients reported problems with physical activity (playing sports) and finding clothing that fit appropriately. Moreover, 75% of female and 68% of male patients reported desiring body contouring surgery. The most important expectation of body contouring surgery was improved appearance, followed by improved self-confidence and quality of life. Surplus skin resulting from gastric bypass surgery is a common issue that causes functional and aesthetic impairments in patients. Consequently, this increases the desire for body contouring surgery with high expectations for the aesthetic outcome as well as improved life satisfaction.

  8. Color and Contour Based Identification of Stem of Coconut Bunch

    Science.gov (United States)

    Kannan Megalingam, Rajesh; Manoharan, Sakthiprasad K.; Reddy, Rajesh G.; Sriteja, Gone; Kashyap, Ashwin

    2017-08-01

    Vision is the key component of Artificial Intelligence and Automated Robotics. Sensors or Cameras are the sight organs for a robot. Only through this, they are able to locate themselves or identify the shape of a regular or an irregular object. This paper presents the method of Identification of an object based on color and contour recognition using a camera through digital image processing techniques for robotic applications. In order to identify the contour, shape matching technique is used, which takes the input data from the database provided, and uses it to identify the contour by checking for shape match. The shape match is based on the idea of iterating through each contour of the threshold image. The color is identified on HSV Scale, by approximating the desired range of values from the database. HSV data along with iteration is used for identifying a quadrilateral, which is our required contour. This algorithm could also be used in a non-deterministic plane, which only uses HSV values exclusively.

  9. Parallel peak pruning for scalable SMP contour tree computation

    Energy Technology Data Exchange (ETDEWEB)

    Carr, Hamish A. [Univ. of Leeds (United Kingdom); Weber, Gunther H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Univ. of California, Davis, CA (United States); Sewell, Christopher M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ahrens, James P. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-09

    As data sets grow to exascale, automated data analysis and visualisation are increasingly important, to intermediate human understanding and to reduce demands on disk storage via in situ analysis. Trends in architecture of high performance computing systems necessitate analysis algorithms to make effective use of combinations of massively multicore and distributed systems. One of the principal analytic tools is the contour tree, which analyses relationships between contours to identify features of more than local importance. Unfortunately, the predominant algorithms for computing the contour tree are explicitly serial, and founded on serial metaphors, which has limited the scalability of this form of analysis. While there is some work on distributed contour tree computation, and separately on hybrid GPU-CPU computation, there is no efficient algorithm with strong formal guarantees on performance allied with fast practical performance. Here in this paper, we report the first shared SMP algorithm for fully parallel contour tree computation, withfor-mal guarantees of O(lgnlgt) parallel steps and O(n lgn) work, and implementations with up to 10x parallel speed up in OpenMP and up to 50x speed up in NVIDIA Thrust.

  10. Foot burns: epidemiology and management.

    Science.gov (United States)

    Hemington-Gorse, S; Pellard, S; Wilson-Jones, N; Potokar, T

    2007-12-01

    This is a retrospective study of the epidemiology and management of isolated foot burns presenting to the Welsh Centre for Burns from January 1998 to December 2002. A total of 289 were treated of which 233 were included in this study. Approximately 40% were in the paediatric age group and the gender distribution varied dramatically for adults and children. In the adult group the male:female ratio was 3.5:1, however in the paediatric group the male:female ratio was more equal (1.6:1). Scald burns (65%) formed the largest group in children and scald (35%) and chemical burns (32%) in adults. Foot burns have a complication rate of 18% and prolonged hospital stay. Complications include hypertrophic scarring, graft loss/delayed healing and wound infection. Although isolated foot burns represent a small body surface area, over half require treatment as in patients to allow for initial aggressive conservative management of elevation and regular wound cleansing to avoid complications. This study suggests a protocol for the initial acute management of foot burns. This protocol states immediate referral of all foot burns to a burn centre, admission of these burns for 24-48 h for elevation, regular wound cleansing with change of dressings and prophylactic antibiotics.

  11. Color contributes to object-contour perception in natural scenes.

    Science.gov (United States)

    Hansen, Thorsten; Gegenfurtner, Karl R

    2017-03-01

    The magnitudes of chromatic and achromatic edge contrast are statistically independent and thus provide independent information, which can be used for object-contour perception. However, it is unclear if and how much object-contour perception benefits from chromatic edge contrast. To address this question, we investigated how well human-marked object contours can be predicted from achromatic and chromatic edge contrast. We used four data sets of human-marked object contours with a total of 824 images. We converted the images to the Derrington-Krauskopf-Lennie color space to separate chromatic from achromatic information in a physiologically meaningful way. Edges were detected in the three dimensions of the color space (one achromatic and two chromatic) and compared to human-marked object contours using receiver operating-characteristic (ROC) analysis for a threshold-independent evaluation. Performance was quantified by the difference of the area under the ROC curves (ΔAUC). Results were consistent across different data sets and edge-detection methods. If chromatic edges were used in addition to achromatic edges, predictions were better for 83% of the images, with a prediction advantage of 3.5% ΔAUC, averaged across all data sets and edge detectors. For some images the prediction advantage was considerably higher, up to 52% ΔAUC. Interestingly, if achromatic edges were used in addition to chromatic edges, the average prediction advantage was smaller (2.4% ΔAUC). We interpret our results such that chromatic information is important for object-contour perception.

  12. Neuronal oscillations form parietal/frontal networks during contour integration.

    Science.gov (United States)

    Castellano, Marta; Plöchl, Michael; Vicente, Raul; Pipa, Gordon

    2014-01-01

    The ability to integrate visual features into a global coherent percept that can be further categorized and manipulated are fundamental abilities of the neural system. While the processing of visual information involves activation of early visual cortices, the recruitment of parietal and frontal cortices has been shown to be crucial for perceptual processes. Yet is it not clear how both cortical and long-range oscillatory activity leads to the integration of visual features into a coherent percept. Here, we will investigate perceptual grouping through the analysis of a contour categorization task, where the local elements that form contour must be linked into a coherent structure, which is then further processed and manipulated to perform the categorization task. The contour formation in our visual stimulus is a dynamic process where, for the first time, visual perception of contours is disentangled from the onset of visual stimulation or from motor preparation, cognitive processes that until now have been behaviorally attached to perceptual processes. Our main finding is that, while local and long-range synchronization at several frequencies seem to be an ongoing phenomena, categorization of a contour could only be predicted through local oscillatory activity within parietal/frontal sources, which in turn, would synchronize at gamma (>30 Hz) frequency. Simultaneously, fronto-parietal beta (13-30 Hz) phase locking forms a network spanning across neural sources that are not category specific. Both long range networks, i.e., the gamma network that is category specific, and the beta network that is not category specific, are functionally distinct but spatially overlapping. Altogether, we show that a critical mechanism underlying contour categorization involves oscillatory activity within parietal/frontal cortices, as well as its synchronization across distal cortical sites.

  13. CT guided diagnostic foot injections

    International Nuclear Information System (INIS)

    Saifuddin, A.; Abdus-Samee, M.; Mann, C.; Singh, D.; Angel, J.C.

    2005-01-01

    AIM: To describe a CT technique for guiding diagnostic and therapeutic injections in the hind- and mid-foot. MATERIALS AND METHODS: Over a period of 50 months, 28 individuals were referred for diagnostic and therapeutic hind- and mid-foot injections before possible arthrodesis. A CT technique was developed that allowed entry into the various joints using a vertical approach. Numbers of joints injected were as follows: posterior subtalar, 21; talonavicular, 4; calcaneonavicular, calcaneocuboid, navicular-cuneiform and 5th metatarsocuboid joints, 1 each. RESULTS: All injections but one were technically successful. Significant relief of symptoms was noted by 16 participants, whereas for 9 there was no improvement and for 3 a partial response was achieved. CONCLUSION: CT is a simple and safe alternative to fluoroscopy for guiding diagnostic and therapeutic foot injections, and may be the technique of choice in cases of disordered anatomy

  14. Luminance contours can gate afterimage colors and "real" colors.

    Science.gov (United States)

    Anstis, Stuart; Vergeer, Mark; Van Lier, Rob

    2012-09-06

    It has long been known that colored images may elicit afterimages in complementary colors. We have already shown (Van Lier, Vergeer, & Anstis, 2009) that one and the same adapting image may result in different afterimage colors, depending on the test contours presented after the colored image. The color of the afterimage depends on two adapting colors, those both inside and outside the test. Here, we further explore this phenomenon and show that the color-contour interactions shown for afterimage colors also occur for "real" colors. We argue that similar mechanisms apply for both types of stimulation.

  15. The Main Cognitive Model of Visual Recognition: Contour Recognition

    OpenAIRE

    Chen, YongHong

    2017-01-01

    In this paper, we will study the following pattern recognition problem: Every pattern is a 3-dimensional graph, its surface can be split up into some regions, every region is composed of the pixels with the approximately same colour value and the approximately same depth value that is distance to eyes, and there may also be some contours, e.g., literal contours, on a surface of every pattern. For this problem we reveal the inherent laws. Moreover, we establish a cognitive model to reflect the...

  16. Contour extraction of echocardiographic images based on pre-processing

    Energy Technology Data Exchange (ETDEWEB)

    Hussein, Zinah Rajab; Rahmat, Rahmita Wirza; Abdullah, Lili Nurliyana [Department of Multimedia, Faculty of Computer Science and Information Technology, Department of Computer and Communication Systems Engineering, Faculty of Engineering University Putra Malaysia 43400 Serdang, Selangor (Malaysia); Zamrin, D M [Department of Surgery, Faculty of Medicine, National University of Malaysia, 56000 Cheras, Kuala Lumpur (Malaysia); Saripan, M Iqbal

    2011-02-15

    In this work we present a technique to extract the heart contours from noisy echocardiograph images. Our technique is based on improving the image before applying contours detection to reduce heavy noise and get better image quality. To perform that, we combine many pre-processing techniques (filtering, morphological operations, and contrast adjustment) to avoid unclear edges and enhance low contrast of echocardiograph images, after implementing these techniques we can get legible detection for heart boundaries and valves movement by traditional edge detection methods.

  17. Contour extraction of echocardiographic images based on pre-processing

    International Nuclear Information System (INIS)

    Hussein, Zinah Rajab; Rahmat, Rahmita Wirza; Abdullah, Lili Nurliyana; Zamrin, D M; Saripan, M Iqbal

    2011-01-01

    In this work we present a technique to extract the heart contours from noisy echocardiograph images. Our technique is based on improving the image before applying contours detection to reduce heavy noise and get better image quality. To perform that, we combine many pre-processing techniques (filtering, morphological operations, and contrast adjustment) to avoid unclear edges and enhance low contrast of echocardiograph images, after implementing these techniques we can get legible detection for heart boundaries and valves movement by traditional edge detection methods.

  18. Complications following body contouring surgery after massive weight loss

    DEFF Research Database (Denmark)

    Hasanbegovic, Emir; Sørensen, Jens Ahm

    2014-01-01

    Bariatric surgery is a way to achieve lasting weight loss in the obese. Body contouring surgery seeks to alleviate some of the discomfort caused by the excessive loose skin following massive weight loss. Higher complication rates are described in this type of surgery when done post......-bariatric. The purpose of this article is to compare complication rates of body contouring surgery when performed on patients with weight loss due to bariatric surgery compared to patients who lost weight due to dietary changes and/or exercise....

  19. The Charcot Foot in Diabetes

    Science.gov (United States)

    Frykberg, Robert G.; Armstrong, David G.; Boulton, Andrew J.M.; Edmonds, Michael; Van, Georges Ha; Hartemann, Agnes; Game, Frances; Jeffcoate, William; Jirkovska, Alexandra; Jude, Edward; Morbach, Stephan; Morrison, William B.; Pinzur, Michael; Pitocco, Dario; Sanders, Lee; Wukich, Dane K.; Uccioli, Luigi

    2011-01-01

    The diabetic Charcot foot syndrome is a serious and potentially limb-threatening lower-extremity complication of diabetes. First described in 1883, this enigmatic condition continues to challenge even the most experienced practitioners. Now considered an inflammatory syndrome, the diabetic Charcot foot is characterized by varying degrees of bone and joint disorganization secondary to underlying neuropathy, trauma, and perturbations of bone metabolism. An international task force of experts was convened by the American Diabetes Association and the American Podiatric Medical Association in January 2011 to summarize available evidence on the pathophysiology, natural history, presentations, and treatment recommendations for this entity. PMID:21868781

  20. Diabetic gangrene of the foot

    International Nuclear Information System (INIS)

    Tanaka, Junji; Hoshi, Makoto; Shinozaki, Tatsuyo; Kimura, Masakata; Ichinohe, Hitomoto.

    1983-01-01

    A case of severe diabetic gangrene was reported. Angiography showed no evidence of ischemic changes in the foot, except for mild atherosclerosis in the femoral and popliteal arteries. Tc-99m labelled macroagglugated albumine (MAA) was injected transcatheterally into the abdominal aorta to see the blood perfusion of the lower extremities, which showed increased blood flow of the foot as well as the presence of micro arteriovenous shuntings shown by the appearance of both lungs. Damages of the microcirculation are thought to have much influences on the formation of diabetic gangrene. Histopathological findings supported above. (author)

  1. Fleet of Foot: Adolescent Foot and Ankle Mobility

    Science.gov (United States)

    Legacy, Kelly Bromley

    2018-01-01

    In today's world of advanced technologies, accessible transportation, and fingertip talking, adolescents are spending too many hours each day sedentary. The purpose of this article is to underscore the importance of foot and ankle mobility in an adolescent population that spends very little time on their feet. Physical educators and athletic…

  2. [Development of a Software for Automatically Generated Contours in Eclipse TPS].

    Science.gov (United States)

    Xie, Zhao; Hu, Jinyou; Zou, Lian; Zhang, Weisha; Zou, Yuxin; Luo, Kelin; Liu, Xiangxiang; Yu, Luxin

    2015-03-01

    The automatic generation of planning targets and auxiliary contours have achieved in Eclipse TPS 11.0. The scripting language autohotkey was used to develop a software for automatically generated contours in Eclipse TPS. This software is named Contour Auto Margin (CAM), which is composed of operational functions of contours, script generated visualization and script file operations. RESULTS Ten cases in different cancers have separately selected, in Eclipse TPS 11.0 scripts generated by the software could not only automatically generate contours but also do contour post-processing. For different cancers, there was no difference between automatically generated contours and manually created contours. The CAM is a user-friendly and powerful software, and can automatically generated contours fast in Eclipse TPS 11.0. With the help of CAM, it greatly save plan preparation time and improve working efficiency of radiation therapy physicists.

  3. Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer.

    Science.gov (United States)

    Lustberg, Tim; van Soest, Johan; Gooding, Mark; Peressutti, Devis; Aljabar, Paul; van der Stoep, Judith; van Elmpt, Wouter; Dekker, Andre

    2018-02-01

    Contouring of organs at risk (OARs) is an important but time consuming part of radiotherapy treatment planning. The aim of this study was to investigate whether using institutional created software-generated contouring will save time if used as a starting point for manual OAR contouring for lung cancer patients. Twenty CT scans of stage I-III NSCLC patients were used to compare user adjusted contours after an atlas-based and deep learning contour, against manual delineation. The lungs, esophagus, spinal cord, heart and mediastinum were contoured for this study. The time to perform the manual tasks was recorded. With a median time of 20 min for manual contouring, the total median time saved was 7.8 min when using atlas-based contouring and 10 min for deep learning contouring. Both atlas based and deep learning adjustment times were significantly lower than manual contouring time for all OARs except for the left lung and esophagus of the atlas based contouring. User adjustment of software generated contours is a viable strategy to reduce contouring time of OARs for lung radiotherapy while conforming to local clinical standards. In addition, deep learning contouring shows promising results compared to existing solutions. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  4. DEVELOPMENT OF VISUALLY GUIDED BEHAVIOR REQUIRES ORIENTED CONTOURS

    NARCIS (Netherlands)

    BRENNER, E; CORNELISSEN, FW

    1992-01-01

    Kittens do not learn to use visual information to guide their behaviour if they are deprived of the optic flow that accompanies their own movements. We show that the optic flow that is required for developing visually guided behaviour is derived from changes in contour orientations, rather than from

  5. Luminance contours can gate afterimage colors and 'real' colors

    NARCIS (Netherlands)

    Anstis, S.; Vergeer, M.L.T.; Lier, R.J. van

    2012-01-01

    It has long been known that colored images may elicit afterimages in complementary colors. We have already shown (Van Lier, Vergeer, & Anstis, 2009) that one and the same adapting image may result in different afterimage colors, depending on the test contours presented after the colored image. The

  6. The role of non-CRF inhibition in contour detection

    NARCIS (Netherlands)

    Grigorescu, C.; Petkov, N.; Westenberg, M.A.

    2003-01-01

    We propose a biologically motivated computational step, called non-classical receptive field (non-CRF) inhibition, to improve the performance of contour detectors. Non-CRF inhibition is exhibited by 80% of the orientation selective neurons in the primary visual cortex of macaque monkeys and has been

  7. Contour detection based on nonclassical receptive field inhibition

    NARCIS (Netherlands)

    Grigorescu, Cosmin; Petkov, Nicolai; Westenberg, Michel A.

    We propose a biologically motivated computational step, called nonclassical receptive field (non-CRF) inhibition, more generally surround inhibition or suppression, to improve contour detection in machine vision. Non-CRF inhibition is exhibited by 80% of the orientation-selective neurons in the

  8. Diffusion coefficients gases, dissolved in fluid of NPPs circulation contours

    International Nuclear Information System (INIS)

    Piontkovskij, A.I.

    2000-01-01

    In article is brought analysis of diverse gases diffusion coefficients computation methods, dissolved in liquid. On the basis of this analysis and treatment of being equalizations for concrete gases and certain parameters offers universal diffusion coefficients determination dependence for diverse gases in wide range of parameters, circulation contours typical for work NPP

  9. Dynamic contour tonometry: presentation of a new tonometer.

    Science.gov (United States)

    Kanngiesser, Hartmut E; Kniestedt, Christoph; Robert, Yves C A

    2005-10-01

    With tonometers currently in use intraocular pressure is indirectly determined by measuring a physical quantity related to a specified deformation of the cornea. We present a new principle of direct, continuous, and transcorneal intraocular pressure measurement, describe its theoretical foundation, and evaluate its application on the basis of an in vitro model. On a living human eye an optimized pressure-sensitive contact surface was determined by performing pressure measurements with differently shaped tonometer heads. Based on these results and on the theoretical model, a Dynamic Contour Tonometer was constructed and validated on eye bank bulbi against a manometric reference pressure. A concave contact surface with a radius of curvature of 10.5 mm creates a distribution of forces between the central contour matching area of the tip and the cornea that equals the forces generated by the internal pressure of the eye. A sensor integrated into the surface having the same contour measures the intraocular pressure closely to the manometric reference pressure in human cadaver eyes. The accuracy of the tonometer appears to be unaffected by variations in corneal properties. Dynamic Contour Tonometry eliminates most of the systematic errors arising from individual changes of corneal properties that adversely influence all types of applanation tonometers. The advantage of measuring the true pressure in combination with the capability of registering dynamic pressure fluctuations discloses new tonometric opportunities to diagnose and classify different types of glaucoma.

  10. Contour tracking and corner detection in a logic programming environment

    DEFF Research Database (Denmark)

    Bell, Benjamin; Pau, L. F.

    1990-01-01

    The added functionality such as contour tracking and corner detection which logic programming lends to standard image operators is described. An environment for implementing low-level imaging operations with Prolog predicates is considered. Within this environment, higher-level image predicates (...

  11. Purse-string platysmaplasty: the third dimension for neck contouring.

    Science.gov (United States)

    Gentile, Richard D

    2005-11-01

    Techniques and concepts for treatment of the aging neck have been evolving since the late 1960s and rely on two-dimensional anterior approximation with lateral imbrication of the platysma with or without submental fat reduction, However, the medial approximation can sometimes give a "boxy" appearance to the anterior neck, especially if anterior shifting of the platysma recurs after platysmaplasty with laxity redeveloping in this midline location. The "purse-string" platysmaplasty (PSP) is a new concept in neck contouring that facilitates an enhanced definition for the cervicomandibular transition to better simulate the well-defined contour of this transition that is present in youth. It aids in the contouring of difficult poorly defined necks and in male patients. The PSP adds a "third dimension" to neck recontouring by invaginating the platysma with a plication suture and pexing the platysma, without incising it, to deeper neck fascia with a technique that adds support and definition to the neck contour. The PSP can be performed in patients undergoing a full rhytidectomy as well as in individuals having isolated neck rejuvenation. The PSP is especially helpful in rejuvenating the male lower face and neck because of the relatively heavier deeper structures of the male neck and the need to enhance definition along the jawline.

  12. Automatic Image Segmentation Using Active Contours with Univariate Marginal Distribution

    Directory of Open Access Journals (Sweden)

    I. Cruz-Aceves

    2013-01-01

    Full Text Available This paper presents a novel automatic image segmentation method based on the theory of active contour models and estimation of distribution algorithms. The proposed method uses the univariate marginal distribution model to infer statistical dependencies between the control points on different active contours. These contours have been generated through an alignment process of reference shape priors, in order to increase the exploration and exploitation capabilities regarding different interactive segmentation techniques. This proposed method is applied in the segmentation of the hollow core in microscopic images of photonic crystal fibers and it is also used to segment the human heart and ventricular areas from datasets of computed tomography and magnetic resonance images, respectively. Moreover, to evaluate the performance of the medical image segmentations compared to regions outlined by experts, a set of similarity measures has been adopted. The experimental results suggest that the proposed image segmentation method outperforms the traditional active contour model and the interactive Tseng method in terms of segmentation accuracy and stability.

  13. LV challenge LKEB contribution : fully automated myocardial contour detection

    NARCIS (Netherlands)

    Wijnhout, J.S.; Hendriksen, D.; Assen, van H.C.; Geest, van der R.J.

    2009-01-01

    In this paper a contour detection method is described and evaluated on the evaluation data sets of the Cardiac MR Left Ventricle Segmentation Challenge as part of MICCAI 2009s 3D Segmentation Challenge for Clinical Applications. The proposed method, using 2D AAM and 3D ASM, performs a fully

  14. Design of a Vibrotactile Vest for Contour Perception

    Directory of Open Access Journals (Sweden)

    Juan Wu

    2012-11-01

    Full Text Available A vibrotactile array is a promising human computer interface which could display graphical information to users in a tactile form. This paper presents the design and testing of an image contour display system with a vibrotactile array. The tactile image display system is attached to the back of the user. It converts visual graphics into 2D tactile images and allows subjects to feel the contours of objects through vibration stimulus. The system consists of a USB camera, 48 (6×8 vibrating motors and an embedded control system. The image is captured by the camera and the 2D contour is extracted and transformed into vibrotactile stimuli using a temporal-spatial dynamic coding method. Preliminary experiments were carried out and the optimal parameters of the vibrating time and duration were explored. To evaluate the feasibility and robustness of this vibration mode, letters were also tactilely displayed and the recognition rate about the alphabet letter display was investigated. It was shown that under the condition of no pre-training for the subjects, the recognition rate was 82%. Such a recognition rate is higher than that of the scanning mode (47.5% and the improved handwriting mode (76.8%. The results indicated that the proposed method was efficient in conveying the contour information to the visually impaired by means of vibrations.

  15. Ship-borne contour integration for flux determination

    NARCIS (Netherlands)

    Groeskamp, S.; Maas, L.R.M.

    2012-01-01

    The consumption of nutrients by mussel beds can be monitored by measuring the net nutrient flux across a circumscribing vertical surface. Measuring this nutrient flux not only requires resolving the spatial (and temporal) distribution of nutrients at the bounding contour, but also an ability to

  16. A phantom study of tumor contouring on PET imaging

    International Nuclear Information System (INIS)

    Chen Song; Li Xuena; Li Yaming; Yin Yafu; Li Na; Han Chunqi

    2010-01-01

    Objective: To explore an algorithm to define the threshold value for tumor contouring on 18 F-fluorodeoxyglucose (FDG) PET imaging. Methods: A National Electrical Manufacturing Association (NEMA)NU 2 1994 PET phantom with 5 spheres of different diameters were filled with 18 F-FDG. Seven different sphere-to-background ratios were obtained and the phantom was scanned by Discovery LS 4. For each sphere-to-background ratio, the maximum standardized uptake value (SUV max ) of each sphere, the SUV of the border of each sphere (SUV border ), the mean SUV of a 1 cm region of background (SUV bg ) and the diameter (D) of each sphere were measured. SPSS 13.0 software was used for curve fitting and regression analysis to obtain the threshold algorithm. The calculated thresholds were applied to delineate 29 pathologically confirmed lung cancer lesions on PET images and the obtained volumes were compared with the volumes contoured on CT images in lung window. Results: The algorithm for defining contour threshold is TH% = 33.1% + 46.8% SUV bg /SUV max + 13.9%/D (r = 0.994) by phantom studies. For 29 lung cancer lesions, the average gross tumor volumes (GTV) delineated on PET and CT are (7.36±1.62) ml and (8.31±2.05) ml, respectively (t = -1.26, P>0.05). Conclusion: The proposed threshold algorithm for tumor contouring on PET image could provide comparable GTV with CT. (authors)

  17. Diabetic foot ulcers. Pathophysiology, assessment, and therapy.

    OpenAIRE

    Bowering, C. K.

    2001-01-01

    OBJECTIVE: To review underlying causes of diabetic foot ulceration, provide a practical assessment of patients at risk, and outline an evidence-based approach to therapy for diabetic patients with foot ulcers. QUALITY OF EVIDENCE: A MEDLINE search was conducted for the period from 1979 to 1999 for articles relating to diabetic foot ulcers. Most studies found were case series or small controlled trials. MAIN MESSAGE: Foot ulcers in diabetic patients are common and frequently lead to lower limb...

  18. X-Ray Exam: Foot

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español X-Ray Exam: Foot KidsHealth / For Parents / X-Ray Exam: ... Muscles, and Joints Broken Bones Getting an X-ray (Video) X-Ray (Video) View more Partner Message About Us ...

  19. Management of diabetic foot infections

    International Nuclear Information System (INIS)

    Jamil, M.; Amin, Z.; Chaudhary, T. H.; Shaheen, J.; Alvi, Z. R.

    2001-01-01

    Objective: To determine the infecting agent in diabetic food infection with the susceptibility pattern, and to evaluate the effect of wound infection, was culopathy, neuropathy and control of diabetes mellitus on the outcome of the patients. Design: A descriptive and observational study. Place and duration of study: Patients with diabetic foot, admitted in surgical unit 1, B.V. Hospital Bahawalpur, from April 1999 to April 2000, were included in this study. Subject and methods: A total of 60 known diabetic patients were studied, out of these 47 were males and 13 females. They were assessed for angiopathy, neuropathy and extend of foot involvement. Necessary investigations, including x-ray foot, ECG, serum urea and creatinine, pus culture and sensitivity were carried out. Diabetes was controlled on insulin of the basis of serum sugar and urine sugar chart and treated accordingly. Results: The most common age of foot involvement was between 40-70 years. Right side was involved more often than the left (67%: 37%). Most of the infections were due to staphylococcus (50%), pseudomonas (25%) and streptococci (8%). Antibiotic was started based on sensitivity report. Fluoro quinolone plus clindamycin was used in 50%, fluoro quinolone plus metronidazole in 20% and amoxicillin/clavulanate in 23%. Most of the patients (61.7%) were in grade iii or iv of Meggit wagner classification of diabetic foot. Three patients (5%) were treated by below knee amputations while 1.7% patient by above knee amputation. In twenty-four (40%) patients some form of to amputation/ray amputation had to be done,while 32(53.3%) patients had complete healing of would without any amputation. Mortality was 3.33% all the 4 patients (6.7%) who presented late, having uncontrolled diabetes, with angiopathy (absent foot pulses), neuropathy, infection of the foot (grade iii or above) resulted in major amputation sooner or latter. The 32 patients (53.3%) having controlled diabetes mellitus with no angiopathy or

  20. 49 CFR 214.115 - Foot protection.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Foot protection. 214.115 Section 214.115... protection. (a) The railroad or railroad contractor shall require railroad bridge workers to wear foot protection equipment when potential foot injury may result from impact, falling or flying objects, electrical...

  1. 24 CFR 3285.312 - Footings.

    Science.gov (United States)

    2010-04-01

    ... reinforcing steel in cast-in-place concrete footings. (2) Pressure-treated wood. (i) Pressure-treated wood footings must consist of a minimum of two layers of nominal 2-inch thick pressure-treated wood, a single... values listed have been reduced by the dead load of the concrete footing. 4. Concrete block piers must...

  2. Standardization of surgical techniques used in facial bone contouring.

    Science.gov (United States)

    Lee, Tae Sung

    2015-12-01

    Since the introduction of facial bone contouring surgery for cosmetic purposes, various surgical methods have been used to improve the aesthetics of facial contours. In general, by standardizing the surgical techniques, it is possible to decrease complication rates and achieve more predictable surgical outcomes, thereby increasing patient satisfaction. The technical strategies used by the author to standardize facial bone contouring procedures are introduced here. The author uses various pre-manufactured surgical tools and hardware for facial bone contouring. During a reduction malarplasty or genioplasty procedure, double-bladed reciprocating saws and pre-bent titanium plates customized for the zygomatic body, arch and chin are used. Various guarded oscillating saws are used for mandibular angloplasty. The use of double-bladed saws and pre-bent plates to perform reduction malarplasty reduces the chances of post-operative asymmetry or under- or overcorrection of the zygoma contours due to technical faults. Inferior alveolar nerve injury and post-operative jawline asymmetry or irregularity can be reduced by using a guarded saw during mandibular angloplasty. For genioplasty, final placement of the chin in accordance with preoperative quantitative analysis can be easily performed with pre-bent plates, and a double-bladed saw allows more procedural accuracy during osteotomies. Efforts by the surgeon to avoid unintentional faults are key to achieving satisfactory results and reducing the incidence of complications. The surgical techniques described in this study in conjunction with various in-house surgical tools and modified hardware can be used to standardize techniques to achieve aesthetically gratifying outcomes. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Diabetes: foot ulcers and amputations.

    Science.gov (United States)

    Hunt, Dereck L

    2011-08-26

    Diabetic foot ulceration is full-thickness penetration of the dermis of the foot in a person with diabetes. Severity is classified using the Wagner system, which grades it from 1 to 5. The annual incidence of ulcers among people with diabetes is 2.5% to 10.7% in resource-rich countries, and the annual incidence of amputation for any reason is 0.25% to 1.8%. We conducted a systematic review and aimed to answer the following clinical questions: What are the effects of interventions to prevent foot ulcers and amputations in people with diabetes? What are the effects of treatments in people with diabetes with foot ulceration? We searched: Medline, Embase, The Cochrane Library, and other important databases up to September 2010 (Clinical Evidence reviews are updated periodically; please check our website for the most up-to-date version of this review). We included harms alerts from relevant organisations such as the US Food and Drug Administration (FDA) and the UK Medicines and Healthcare products Regulatory Agency (MHRA). We found 50 systematic reviews and RCTs that met our inclusion criteria. We performed a GRADE evaluation of the quality of evidence for interventions. In this systematic review, we present information relating to the effectiveness and safety of the following interventions: debridement, human cultured dermis, human skin equivalent, patient education, pressure off-loading with felted foam or pressure-relief half-shoe, pressure off-loading with total-contact or non-removable casts, screening and referral to foot-care clinics, systemic hyperbaric oxygen for non-infected ulcers, systemic hyperbaric oxygen in infected ulcers, therapeutic footwear, topical growth factors, and wound dressings.

  4. Foot Problems in a Group of Patients with Rheumatoid Arthritis: An Unmet Need for Foot Care

    OpenAIRE

    Borman, Pinar; Ayhan, Figen; Tuncay, Figen; Sahin, Mehtap

    2012-01-01

    Objectives: The aim of this study was to evaluate the foot involvement in a group of RA patients in regard to symptoms, type and frequency of deformities, location, radiological changes, and foot care. Patients and Methods: A randomized selected 100 rheumatoid arthritis (RA) patients were recruited to the study. Data about foot symptoms, duration and location of foot pain, pain intensity, access to services related to foot, treatment, orthoses and assistive devices, and usefulness of therapie...

  5. SU-E-J-129: Atlas Development for Cardiac Automatic Contouring Using Multi-Atlas Segmentation

    International Nuclear Information System (INIS)

    Zhou, R; Yang, J; Pan, T; Milgrom, S; Pinnix, C; Shi, A; Yang, J; Liu, Y; Nguyen, Q; Gomez, D; Dabaja, B; Balter, P; Court, L; Liao, Z

    2015-01-01

    Purpose: To develop a set of atlases for automatic contouring of cardiac structures to determine heart radiation dose and the associated toxicity. Methods: Six thoracic cancer patients with both contrast and non-contrast CT images were acquired for this study. Eight radiation oncologists manually and independently delineated cardiac contours on the non-contrast CT by referring to the fused contrast CT and following the RTOG 1106 atlas contouring guideline. Fifteen regions of interest (ROIs) were delineated, including heart, four chambers, four coronary arteries, pulmonary artery and vein, inferior and superior vena cava, and ascending and descending aorta. Individual expert contours were fused using the simultaneous truth and performance level estimation (STAPLE) algorithm for each ROI and each patient. The fused contours became atlases for an in-house multi-atlas segmentation. Using leave-one-out test, we generated auto-segmented contours for each ROI and each patient. The auto-segmented contours were compared with the fused contours using the Dice similarity coefficient (DSC) and the mean surface distance (MSD). Results: Inter-observer variability was not obvious for heart, chambers, and aorta but was large for other structures that were not clearly distinguishable on CT image. The average DSC between individual expert contours and the fused contours were less than 50% for coronary arteries and pulmonary vein, and the average MSD were greater than 4.0 mm. The largest MSD of expert contours deviating from the fused contours was 2.5 cm. The mean DSC and MSD of auto-segmented contours were within one standard deviation of expert contouring variability except the right coronary artery. The coronary arteries, vena cava, and pulmonary vein had DSC<70% and MSD>3.0 mm. Conclusion: A set of cardiac atlases was created for cardiac automatic contouring, the accuracy of which was comparable to the variability in expert contouring. However, substantial modification may need

  6. Active contour-based visual tracking by integrating colors, shapes, and motions.

    Science.gov (United States)

    Hu, Weiming; Zhou, Xue; Li, Wei; Luo, Wenhan; Zhang, Xiaoqin; Maybank, Stephen

    2013-05-01

    In this paper, we present a framework for active contour-based visual tracking using level sets. The main components of our framework include contour-based tracking initialization, color-based contour evolution, adaptive shape-based contour evolution for non-periodic motions, dynamic shape-based contour evolution for periodic motions, and the handling of abrupt motions. For the initialization of contour-based tracking, we develop an optical flow-based algorithm for automatically initializing contours at the first frame. For the color-based contour evolution, Markov random field theory is used to measure correlations between values of neighboring pixels for posterior probability estimation. For adaptive shape-based contour evolution, the global shape information and the local color information are combined to hierarchically evolve the contour, and a flexible shape updating model is constructed. For the dynamic shape-based contour evolution, a shape mode transition matrix is learnt to characterize the temporal correlations of object shapes. For the handling of abrupt motions, particle swarm optimization is adopted to capture the global motion which is applied to the contour in the current frame to produce an initial contour in the next frame.

  7. An investigation into positron emission tomography contouring methods across two treatment planning systems

    International Nuclear Information System (INIS)

    Young, Tony; Som, Seu; Sathiakumar, Chithradevi; Holloway, Lois

    2013-01-01

    Positron emission tomography (PET) imaging has been used to provide additional information regarding patient tumor location, size, and staging for radiotherapy treatment planning purposes. This additional information reduces interobserver variability and produces more consistent contouring. It is well recognized that different contouring methodology for PET data results in different contoured volumes. The goal of this study was to compare the difference in PET contouring methods for 2 different treatment planning systems using a phantom dataset and a series of patient datasets. Contouring methodology was compared on the ADAC Pinnacle Treatment Planning System and the CMS XiO Treatment Planning System. Contours were completed on the phantom and patient datasets using a number of PET contouring methods—the standardized uptake value 2.5 method, 30%, 40%, and 50% of the maximum uptake method and the signal to background ratio method. Differences of >15% were observed for PET-contoured volumes between the different treatment planning systems for the same data and the same PET contouring methodology. Contoured volume differences between treatment planning systems were caused by differences in data formatting and display and the different contouring tools available. Differences in treatment planning system as well as contouring methodology should be considered carefully in dose-volume contouring and reporting, especially between centers that may use different treatment planning systems or those that have several different treatment planning systems

  8. Sural artery perforator flap with posterior tibial neurovascular decompression for recurrent foot ulcer in leprosy patients

    Directory of Open Access Journals (Sweden)

    Ismail, Hossam El-din Ali

    2017-01-01

    Full Text Available Introduction: The sensory loss and alteration of the shape of the foot make the foot liable to trauma and pressure, and subsequently cause more callus formation, blisters, and ulcers. Foot ulcers usually are liable to secondary infection as cellulitis or osteomyelitis, and may result in amputations. Foot ulcers are a major problem and a major cause of handicaps in leprosy patients. The current study is to present our clinical experience and evaluate the use of sural flap with posterior tibial neurovascular decompression (PTND in recurrent foot ulcers in leprosy patients.Patient and methods: A total number of 9 patients were suffering from chronic sequelae of leprosy as recurrent foot ulcers. All the patients were reconstructed with the reverse sural artery fasciocutaneous flap with posterior tibial neurovascular decompression from September 2012 to August 2015. Six patients were male and three were female with a mean age of 39.8 years (range, 30–50 years. All the soft tissue defects were in the weight-bearing area of the inside of the foot. The flap sizes ranged from 15/4 to 18/6 cm. Mean follow-up period was 21.2 months (range, 35–2 months.Results: All the flaps healed uneventfully. There was no major complication as total flap necrosis. Only minor complications occurred which were treated without surgical intervention except in two patients who developed superficial necrosis of the skin paddle. Surgical debridement was done one week later. The flap was completely viable after surgery, and the contour of the foot was restored. We found that an improvement of sensation occurred in those patients in whom the anesthesia started one year ago or less and no sensory recovery in patient in whom the anesthesia had lasted for more than two years.Conclusion: The reverse sural artery flap with posterior tibial neurovascular decompression provides a reliable method for recurrent foot soft tissue reconstruction in leprosy patients with encouraging

  9. Calf Contouring with Endoscopic Fascial Release, Calf Implant, and Structural Fat Grafting

    Directory of Open Access Journals (Sweden)

    Ercan Karacaoglu, MD

    2013-08-01

    Conclusions: A novel endoscopic approach for lower leg contouring is discussed. Endoscopic fasciotomy technique with calf implant and structural fat grafting for improved lower leg aesthetics is a simple, effective, reliable, and predictable technique for calf contouring.

  10. Obese older adults suffer foot pain and foot-related functional limitation.

    Science.gov (United States)

    Mickle, Karen J; Steele, Julie R

    2015-10-01

    There is evidence to suggest being overweight or obese places adults at greater risk of developing foot complications such as osteoarthritis, tendonitis and plantar fasciitis. However, no research has comprehensively examined the effects of overweight or obesity on the feet of individuals older than 60 years of age. Therefore we investigated whether foot pain, foot structure, and/or foot function is affected by obesity in older adults. Three hundred and twelve Australian men and women, aged over 60 years, completed validated questionnaires to establish the presence of foot pain and health related quality of life. Foot structure (anthropometrics and soft tissue thickness) and foot function (ankle dorsiflexion strength and flexibility, toe flexor strength, plantar pressures and spatiotemporal gait parameters) were also measured. Obese participants (BMI >30) were compared to those who were overweight (BMI=25-30) and not overweight (BMI foot pain and scored significantly lower on the SF-36. Obesity was also associated with foot-related functional limitation whereby ankle dorsiflexion strength, hallux and lesser toe strength, stride/step length and walking speed were significantly reduced in obese participants compared to their leaner counterparts. Therefore, disabling foot pain and altered foot structure and foot function are consequences of obesity for older adults, and impact upon their quality of life. Interventions designed to reduce excess fat mass may relieve loading of the foot structures and, in turn, improve foot pain and quality of life for older obese individuals. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Perceptual representation and effectiveness of local figure-ground cues in natural contours.

    Science.gov (United States)

    Sakai, Ko; Matsuoka, Shouhei; Kurematsu, Ken; Hatori, Yasuhiro

    2015-01-01

    A contour shape strongly influences the perceptual segregation of a figure from the ground. We investigated the contribution of local contour shape to figure-ground segregation. Although previous studies have reported local contour features that evoke figure-ground perception, they were often image features and not necessarily perceptual features. First, we examined whether contour features, specifically, convexity, closure, and symmetry, underlie the perceptual representation of natural contour shapes. We performed similarity tests between local contours, and examined the contribution of the contour features to the perceptual similarities between the contours. The local contours were sampled from natural contours so that their distribution was uniform in the space composed of the three contour features. This sampling ensured the equal appearance frequency of the factors and a wide variety of contour shapes including those comprised of contradictory factors that induce figure in the opposite directions. This sampling from natural contours is advantageous in order to randomly pickup a variety of contours that satisfy a wide range of cue combinations. Multidimensional scaling analyses showed that the combinations of convexity, closure, and symmetry contribute to perceptual similarity, thus they are perceptual quantities. Second, we examined whether the three features contribute to local figure-ground perception. We performed psychophysical experiments to judge the direction of the figure along the local contours, and examined the contribution of the features to the figure-ground judgment. Multiple linear regression analyses showed that closure was a significant factor, but that convexity and symmetry were not. These results indicate that closure is dominant in the local figure-ground perception with natural contours when the other cues coexist with equal probability including contradictory cases.

  12. Perceptual representation and effectiveness of local figure–ground cues in natural contours

    Science.gov (United States)

    Sakai, Ko; Matsuoka, Shouhei; Kurematsu, Ken; Hatori, Yasuhiro

    2015-01-01

    A contour shape strongly influences the perceptual segregation of a figure from the ground. We investigated the contribution of local contour shape to figure–ground segregation. Although previous studies have reported local contour features that evoke figure–ground perception, they were often image features and not necessarily perceptual features. First, we examined whether contour features, specifically, convexity, closure, and symmetry, underlie the perceptual representation of natural contour shapes. We performed similarity tests between local contours, and examined the contribution of the contour features to the perceptual similarities between the contours. The local contours were sampled from natural contours so that their distribution was uniform in the space composed of the three contour features. This sampling ensured the equal appearance frequency of the factors and a wide variety of contour shapes including those comprised of contradictory factors that induce figure in the opposite directions. This sampling from natural contours is advantageous in order to randomly pickup a variety of contours that satisfy a wide range of cue combinations. Multidimensional scaling analyses showed that the combinations of convexity, closure, and symmetry contribute to perceptual similarity, thus they are perceptual quantities. Second, we examined whether the three features contribute to local figure–ground perception. We performed psychophysical experiments to judge the direction of the figure along the local contours, and examined the contribution of the features to the figure–ground judgment. Multiple linear regression analyses showed that closure was a significant factor, but that convexity and symmetry were not. These results indicate that closure is dominant in the local figure–ground perception with natural contours when the other cues coexist with equal probability including contradictory cases. PMID:26579057

  13. Perceptual Representation and Effectiveness of Local Figure-Ground Cues in Natural Contours

    Directory of Open Access Journals (Sweden)

    Ko eSakai

    2015-11-01

    Full Text Available A contour shape strongly influences the perceptual segregation of a figure from the ground. We investigated the contribution of local contour shape to figure-ground segregation. Although previous studies have reported local contour features that evoke figure-ground perception, they were often image features and not necessarily perceptual features. First, we examined whether contour features, specifically, convexity, closure, and symmetry, underlie the perceptual representation of natural contour shapes. We performed similarity tests between local contours, and examined the contribution of the contour features to the perceptual similarities between the contours. The local contours were sampled from natural contours so that their distribution was uniform in the space composed of the three contour features. This sampling ensured the equal appearance frequency of the factors and a wide variety of contour shapes including those comprised of contradictory factors that induce figure in the opposite directions. This sampling from natural contours is advantageous in order to randomly pickup a variety of contours that satisfy a wide range of cue combinations. Multidimensional scaling analyses showed that the combinations of convexity, closure, and symmetry contribute to perceptual similarity, thus they are perceptual quantities. Second, we examined whether the three features contribute to local figure-ground perception. We performed psychophysical experiments to judge the direction of the figure along the local contours, and examined the contribution of the features to the figure-ground judgment. Multiple linear regression analyses showed that closure was a significant factor, but that convexity and symmetry were not. These results indicate that closure is dominant in the local figure-ground perception with natural contours when the other cues coexist with equal probability including contradictory cases.

  14. Perceptual representation and effectiveness of local figure?ground cues in natural contours

    OpenAIRE

    Sakai, Ko; Matsuoka, Shouhei; Kurematsu, Ken; Hatori, Yasuhiro

    2015-01-01

    A contour shape strongly influences the perceptual segregation of a figure from the ground. We investigated the contribution of local contour shape to figure–ground segregation. Although previous studies have reported local contour features that evoke figure–ground perception, they were often image features and not necessarily perceptual features. First, we examined whether contour features, specifically, convexity, closure, and symmetry, underlie the perceptual representation of natural cont...

  15. Foot-and-Mouth Disease

    OpenAIRE

    Grubman, Marvin J.; Baxt, Barry

    2004-01-01

    Foot-and-mouth disease (FMD) is a highly contagious disease of cloven-hoofed animals. The disease was initially described in the 16th century and was the first animal pathogen identified as a virus. Recent FMD outbreaks in developed countries and their significant economic impact have increased the concern of governments worldwide. This review describes the reemergence of FMD in developed countries that had been disease free for many years and the effect that this has had on disease control s...

  16. Contour analysis of steady state tokamak reactor performance

    International Nuclear Information System (INIS)

    Devoto, R.S.; Fenstermacher, M.E.

    1990-01-01

    A new method of analysis for presenting the possible operating space for steady state, non-ignited tokamak reactors is proposed. The method uses contours of reactor performance and plasma characteristics, fusion power gain, wall neutron flux, current drive power, etc., plotted on a two-dimensional grid, the axes of which are the plasma current I p and the normalized beta, β n = β/(I p /aB 0 ), to show possible operating points. These steady state operating contour plots are called SOPCONS. This technique is illustrated in an application to a design for the International Thermonuclear Experimental Reactor (ITER) with neutral beam, lower hybrid and bootstrap current drive. The utility of the SOPCON plots for pointing out some of the non-intuitive considerations in steady state reactor design is shown. (author). Letter-to-the-editor. 16 refs, 3 figs, 1 tab

  17. Diffusion tensor driven contour closing for cell microinjection targeting.

    Science.gov (United States)

    Becattini, Gabriele; Mattos, Leonardo S; Caldwell, Darwin G

    2010-01-01

    This article introduces a novel approach to robust automatic detection of unstained living cells in bright-field (BF) microscope images with the goal of producing a target list for an automated microinjection system. The overall image analysis process is described and includes: preprocessing, ridge enhancement, image segmentation, shape analysis and injection point definition. The developed algorithm implements a new version of anisotropic contour completion (ACC) based on the partial differential equation (PDE) for heat diffusion which improves the cell segmentation process by elongating the edges only along their tangent direction. The developed ACC algorithm is equivalent to a dilation of the binary edge image with a continuous elliptic structural element that takes into account local orientation of the contours preventing extension towards normal direction. Experiments carried out on real images of 10 to 50 microm CHO-K1 adherent cells show a remarkable reliability in the algorithm along with up to 85% success for cell detection and injection point definition.

  18. Fast Graph Partitioning Active Contours for Image Segmentation Using Histograms

    Directory of Open Access Journals (Sweden)

    Nath SumitK

    2009-01-01

    Full Text Available Abstract We present a method to improve the accuracy and speed, as well as significantly reduce the memory requirements, for the recently proposed Graph Partitioning Active Contours (GPACs algorithm for image segmentation in the work of Sumengen and Manjunath (2006. Instead of computing an approximate but still expensive dissimilarity matrix of quadratic size, , for a 2D image of size and regular image tiles of size , we use fixed length histograms and an intensity-based symmetric-centrosymmetric extensor matrix to jointly compute terms associated with the complete dissimilarity matrix. This computationally efficient reformulation of GPAC using a very small memory footprint offers two distinct advantages over the original implementation. It speeds up convergence of the evolving active contour and seamlessly extends performance of GPAC to multidimensional images.

  19. The method of contour rotations and the three particle amplitudes

    International Nuclear Information System (INIS)

    Brinati, J.R.

    1980-01-01

    The application of the method of contour rotations to the solution of the Faddeev-Lovelace equations and the calculation of the break-up and stripping amplitudes in a system of three distinct particles is reviewed. A relationship between the masses of the particles is obtained, which permits the break-up amplitude to be calculated from a single iteration of the final integral equation. (Author) [pt

  20. Dynamic identification of plasma magnetic contour in fusion machines

    International Nuclear Information System (INIS)

    Bettini, P.; Trevisan, F.; Cavinato, M.

    2005-01-01

    The paper presents a method to identify the plasma magnetic contour in fusion machines, when eddy currents are present in the conducting structures surrounding the plasma. The approach presented is based on the integration of an electromagnetic model of the plasma with a lumped parameters model of the conducting structures around the plasma. This approach has been validated against experimental data from RFX, a reversed field pinch machine. (author)

  1. An improved active contour model for glacial lake extraction

    Science.gov (United States)

    Zhao, H.; Chen, F.; Zhang, M.

    2017-12-01

    Active contour model is a widely used method in visual tracking and image segmentation. Under the driven of objective function, the initial curve defined in active contour model will evolve to a stable condition - a desired result in given image. As a typical region-based active contour model, C-V model has a good effect on weak boundaries detection and anti noise ability which shows great potential in glacial lake extraction. Glacial lake is a sensitive indicator for reflecting global climate change, therefore accurate delineate glacial lake boundaries is essential to evaluate hydrologic environment and living environment. However, the current method in glacial lake extraction mainly contains water index method and recognition classification method are diffcult to directly applied in large scale glacial lake extraction due to the diversity of glacial lakes and masses impacted factors in the image, such as image noise, shadows, snow and ice, etc. Regarding the abovementioned advantanges of C-V model and diffcults in glacial lake extraction, we introduce the signed pressure force function to improve the C-V model for adapting to processing of glacial lake extraction. To inspect the effect of glacial lake extraction results, three typical glacial lake development sites were selected, include Altai mountains, Centre Himalayas, South-eastern Tibet, and Landsat8 OLI imagery was conducted as experiment data source, Google earth imagery as reference data for varifying the results. The experiment consequence suggests that improved active contour model we proposed can effectively discriminate the glacial lakes from complex backgound with a higher Kappa Coefficient - 0.895, especially in some small glacial lakes which belongs to weak information in the image. Our finding provide a new approach to improved accuracy under the condition of large proportion of small glacial lakes and the possibility for automated glacial lake mapping in large-scale area.

  2. Development of optical surface contouring technique using laser

    Energy Technology Data Exchange (ETDEWEB)

    Baik, Sung Hoon; Kim, Min Suk; Park, Seung Kyu

    1998-12-01

    Laser contouring system capable of measuring relief profiles using a line-shaped laser beam with anisotropic magnification optics composed with two cylindrical lenses was developed. The anisotropic magnification optical system allows it to obtain higher resolution in the relief profile measurements. The image processing and 3-D display software are developed to reconstruct 3-D shape. The power supply of laser diode with adaptive current control circuit is designed. (author). 4 refs., 5 tabs., 33 figs.

  3. An Experimental and Analytical Study on perpendicular to plane Flexural behavior of New Prefabricated Wall Made by Extruded Polystyrene

    Directory of Open Access Journals (Sweden)

    Omid Rezayfar

    2017-07-01

    Full Text Available Nowadays softening of non-structural components as well as applying dry-wall systems are one of the efficacious measures to safe constructions against earthquakes. Using rigid and heavy non-structural elements, increase earthquake force and its destructive effects on the structure. Therefore, using flexible and light material in non-structural elements is one of the effective solutions to build light and safe structures against earthquakes. In this study, an experimental and analytical investigation on the behaviour of a new pre-fabricated wall made by extruded polystyrene, gypsum board and cement board has been studied through a comparative analysis that the following conclusions can be drawn. C-C Panels have 35% More resistance and G-G Panels have 37% more Plasticity. Thickness has positive effects on resistance and plasticity. Panels with thickness of 12.5cm have 37% more resistance and 21% more plasticity in comparison with panels with thickness of 7.5 cm.

  4. Analysis of the Seismic Performance of Site-Bolted Beam to Column Connections in Modularized Prefabricated Steel Structures

    Directory of Open Access Journals (Sweden)

    Xuechun Liu

    2017-01-01

    Full Text Available This paper proposes a site-bolted connection that is suitable for modularized prefabricated steel structures. Excellent ductility is achieved by various structural measures. Six connection specimens with different parameters were subjected to quasi-static loading tests and finite element analysis (FEA to determine the seismic performance of the proposed connection (e.g., hysteretic behavior, skeleton curve, ductility, and failure mode. The results of the tests and FEA showed that the connection underwent sufficient plastic deformation under cyclic loading and that its ultimate rotation angle could reach 0.09 rad. A clear plastic hinge formed on the beam before the connection failed, which suggests a ductile failure mode. The connection exhibited a wide hysteresis loop, which indicated good seismic performance. The results also showed that the connection does not slip under small earthquakes and could dissipate energy through slippage in the connection region under a moderate earthquake and through slippage in the connection region as well as plastic deformation at the beam end under a severe earthquake. The number of bolts was the main parameter that affected the seismic performance of the connection. The test and FEA results demonstrated that all six specimens had excellent seismic and ductile performance and an exceptional plastic rotation capacity.

  5. Soil settlement analysis in soft soil by using preloading system and prefabricated vertical draining runway of Kualanamu Airport

    Science.gov (United States)

    Roesyanto; Iskandar, R.; Silalahi, S. A.; Fadliansyah

    2018-02-01

    The method of soil improvement, using the combination of prefabricated vertical drain (PVD) and preloading, was used to accelerate the process of consolidation and the consolidation settlement in the runway of Kualanamu International Airport, which was constructed on the soft soil sediment like silty clay. In this research, the investigated area was the runway of Kualanamu International Airport zone I which had 11 meter-thickness of soft soil. Geotechnic instruments surveyed was settlement plate. Monitoring was done toward the behavior of landfill such as basic soil settlement. The result were compared with the analysis of finite element method of full scale in Mohr-Coulomb model by verifying the vertical drain of asymmetric unit cell and equivalent plane strain unit cell condition. The results of the research showed that there were an interesting behavior between the data in field observation and finite element of Mohr-Coulomb model. It was also found that the result of soil settlement of finite element method of Mohr-Coulomb model was closed to the result of settlement plate monitoring.

  6. Angiographic Evaluation of Carotid Artery Grafting with Prefabricated Small-Diameter, Small-Intestinal Submucosa Grafts in Sheep

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Obermiller, Josef; Uchida, Barry T.; Van Alstine, William; Edwards, James M.; Landry, Gregory J.; Kaufman, John A.; Keller, Frederick S.; Roesch, Josef

    2009-01-01

    The purpose of this study was to report the longitudinal angiographic evaluation of prefabricated lyophilized small-intestinal submucosa (SIS) grafts placed in ovine carotid arteries and to demonstrate a variety of complications that developed. A total of 24 grafts, 10 cm long and 6 mm in diameter, were placed surgically as interposition grafts. Graft patency at 1 week was evaluated by Doppler ultrasound, and angiography was used for follow-up at 1 month and at 3 to 4 months. A 90% patency rate was found at 1 week, 65% at 1 month, and 30% at 3 to 4 months. On the patent grafts, angiography demonstrated a variety of changes, such as anastomotic stenoses, graft diffuse dilations and dissections, and aneurysm formation. These findings have not been previously demonstrated angiographically by other investigators reporting results with small-diameter vessel grafts made from fresh small-intestinal submucosa (SIS). The complications found were partially related to the graft construction from four SIS layers. Detailed longitudinal angiographic study should become an essential part of any future evaluation of small-vessel SIS grafting.

  7. The Effect of Contouring Variability on Dosimetric Parameters for Brain Metastases Treated With Stereotactic Radiosurgery

    International Nuclear Information System (INIS)

    Stanley, Julia; Dunscombe, Peter; Lau, Harold; Burns, Paul; Lim, Gerald; Liu, Hong-Wei; Nordal, Robert; Starreveld, Yves; Valev, Boris; Voroney, Jon-Paul; Spencer, David P.

    2013-01-01

    Purpose: To quantify the effect of contouring variation on stereotactic radiosurgery plan quality metrics for brain metastases. Methods and Materials: Fourteen metastases, each contoured by 8 physicians, formed the basis of this study. A template-based dynamic conformal 5-arc dose distribution was developed for each of the 112 contours, and each dose distribution was applied to the 7 other contours in each patient set. Radiation Therapy Oncology Group (RTOG) plan quality metrics and the Paddick conformity index were calculated for each of the 896 combinations of dose distributions and contours. Results: The ratio of largest to smallest contour volume for each metastasis varied from 1.25 to 4.47, with a median value of 1.68 (n=8). The median absolute difference in RTOG conformity index between the value for the reference contour and the values for the alternative contours was 0.35. The variation of the range of conformity index for all contours for a given tumor varied with the tumor size. Conclusions: The high degree of interobserver contouring variation strongly suggests that peer review or consultation should be adopted to standardize tumor volume prescription. Observer confidence was not reflected in contouring consistency. The impact of contouring variability on plan quality metrics, used as criteria for clinical trial protocol compliance, was such that the category of compliance was robust to interobserver effects only 70% of the time

  8. Transference of Fermi Contour Anisotropy to Composite Fermions.

    Science.gov (United States)

    Jo, Insun; Rosales, K A Villegas; Mueed, M A; Pfeiffer, L N; West, K W; Baldwin, K W; Winkler, R; Padmanabhan, Medini; Shayegan, M

    2017-07-07

    There has been a surge of recent interest in the role of anisotropy in interaction-induced phenomena in two-dimensional (2D) charged carrier systems. A fundamental question is how an anisotropy in the energy-band structure of the carriers at zero magnetic field affects the properties of the interacting particles at high fields, in particular of the composite fermions (CFs) and the fractional quantum Hall states (FQHSs). We demonstrate here tunable anisotropy for holes and hole-flux CFs confined to GaAs quantum wells, via applying in situ in-plane strain and measuring their Fermi wave vector anisotropy through commensurability oscillations. For strains on the order of 10^{-4} we observe significant deformations of the shapes of the Fermi contours for both holes and CFs. The measured Fermi contour anisotropy for CFs at high magnetic field (α_{CF}) is less than the anisotropy of their low-field hole (fermion) counterparts (α_{F}), and closely follows the relation α_{CF}=sqrt[α_{F}]. The energy gap measured for the ν=2/3 FQHS, on the other hand, is nearly unaffected by the Fermi contour anisotropy up to α_{F}∼3.3, the highest anisotropy achieved in our experiments.

  9. Gallbladder shape extraction from ultrasound images using active contour models.

    Science.gov (United States)

    Ciecholewski, Marcin; Chochołowicz, Jakub

    2013-12-01

    Gallbladder function is routinely assessed using ultrasonographic (USG) examinations. In clinical practice, doctors very often analyse the gallbladder shape when diagnosing selected disorders, e.g. if there are turns or folds of the gallbladder, so extracting its shape from USG images using supporting software can simplify a diagnosis that is often difficult to make. The paper describes two active contour models: the edge-based model and the region-based model making use of a morphological approach, both designed for extracting the gallbladder shape from USG images. The active contour models were applied to USG images without lesions and to those showing specific disease units, namely, anatomical changes like folds and turns of the gallbladder as well as polyps and gallstones. This paper also presents modifications of the edge-based model, such as the method for removing self-crossings and loops or the method of dampening the inflation force which moves nodes if they approach the edge being determined. The user is also able to add a fragment of the approximated edge beyond which neither active contour model will move if this edge is incomplete in the USG image. The modifications of the edge-based model presented here allow more precise results to be obtained when extracting the shape of the gallbladder from USG images than if the morphological model is used. © 2013 Elsevier Ltd. Published by Elsevier Ltd. All rights reserved.

  10. Contour Detection for UAV-Based Cadastral Mapping

    Directory of Open Access Journals (Sweden)

    Sophie Crommelinck

    2017-02-01

    Full Text Available Unmanned aerial vehicles (UAVs provide a flexible and low-cost solution for the acquisition of high-resolution data. The potential of high-resolution UAV imagery to create and update cadastral maps is being increasingly investigated. Existing procedures generally involve substantial fieldwork and many manual processes. Arguably, multiple parts of UAV-based cadastral mapping workflows could be automated. Specifically, as many cadastral boundaries coincide with visible boundaries, they could be extracted automatically using image analysis methods. This study investigates the transferability of gPb contour detection, a state-of-the-art computer vision method, to remotely sensed UAV images and UAV-based cadastral mapping. Results show that the approach is transferable to UAV data and automated cadastral mapping: object contours are comprehensively detected at completeness and correctness rates of up to 80%. The detection quality is optimal when the entire scene is covered with one orthoimage, due to the global optimization of gPb contour detection. However, a balance between high completeness and correctness is hard to achieve, so a combination with area-based segmentation and further object knowledge is proposed. The localization quality exhibits the usual dependency on ground resolution. The approach has the potential to accelerate the process of general boundary delineation during the creation and updating of cadastral maps.

  11. The relative pose estimation of aircraft based on contour model

    Science.gov (United States)

    Fu, Tai; Sun, Xiangyi

    2017-02-01

    This paper proposes a relative pose estimation approach based on object contour model. The first step is to obtain a two-dimensional (2D) projection of three-dimensional (3D)-model-based target, which will be divided into 40 forms by clustering and LDA analysis. Then we proceed by extracting the target contour in each image and computing their Pseudo-Zernike Moments (PZM), thus a model library is constructed in an offline mode. Next, we spot a projection contour that resembles the target silhouette most in the present image from the model library with reference of PZM; then similarity transformation parameters are generated as the shape context is applied to match the silhouette sampling location, from which the identification parameters of target can be further derived. Identification parameters are converted to relative pose parameters, in the premise that these values are the initial result calculated via iterative refinement algorithm, as the relative pose parameter is in the neighborhood of actual ones. At last, Distance Image Iterative Least Squares (DI-ILS) is employed to acquire the ultimate relative pose parameters.

  12. Closed contour fractal dimension estimation by the Fourier transform

    International Nuclear Information System (INIS)

    Florindo, J.B.; Bruno, O.M.

    2011-01-01

    Highlights: → A novel fractal dimension concept, based on Fourier spectrum, is proposed. → Computationally simple. Computational time smaller than conventional fractal methods. → Results are closer to Hausdorff-Besicovitch than conventional methods. → The method is more accurate and robustness to geometric operations and noise addition. - Abstract: This work proposes a novel technique for the numerical calculus of the fractal dimension of fractal objects which can be represented as a closed contour. The proposed method maps the fractal contour onto a complex signal and calculates its fractal dimension using the Fourier transform. The Fourier power spectrum is obtained and an exponential relation is verified between the power and the frequency. From the parameter (exponent) of the relation, is obtained the fractal dimension. The method is compared to other classical fractal dimension estimation methods in the literature, e.g., Bouligand-Minkowski, box-counting and classical Fourier. The comparison is achieved by the calculus of the fractal dimension of fractal contours whose dimensions are well-known analytically. The results showed the high precision and robustness of the proposed technique.

  13. Heavy ion scattering in 3D TDHF. [Isodensity contours

    Energy Technology Data Exchange (ETDEWEB)

    Weiss, M.S.

    1977-09-01

    Results of three-dimensional (3D) time-dependent Hartree--Fock (TDHF) calculations are presented. The assumptions used in the calculations are summarized. The first reaction considered is /sup 16/O + /sup 16/O at 105 MeV (lab); isodensity contours integrated perpendicular to the reaction plane are shown for several impact parameters as a function of time. Trajectories are also shown, and the kinetics of the reaction is discussed; several other energies were also examined. Most of the deeply inelastic scattering seems to come from small impact parameters. Density contours and trajectories are next shown for /sup 40/Ca + /sup 40/Ca at 278 MeV (lab). Finally, density contours are shown for asymmetric systems: /sup 4/He + /sup 16/O at l = 5 h-bar and 50 MeV (lab) and /sup 16/O + /sup 40/Ca at l = 20, 40, 60, 80 h-bar and 315 MeV (lab). The light fragment seems to maintain the same average number of nucleons with which it started. 25 figures. (RWR)

  14. The ankle-foot orthosis improves balance and reduces fall risk of chronic spastic hemiparetic patients.

    Science.gov (United States)

    Cakar, E; Durmus, O; Tekin, L; Dincer, U; Kiralp, M Z

    2010-09-01

    Ankle foot orthoses (AFO) are commonly used orthotic device in order to restore the ankle foot function and to improve the balance and gait in post-stroke hemiparetic patients. However, there remain some discussions about their effectiveness on long term hemiparetic patients who had mild to moderate spasticity. To investigate the relative effect of prefabricated thermoplastic posterior leaf spring AFO (PLS-AFO) on balance and fall risk. A cross-over interventional study The Department of PMR of a tertiary hospital. Twenty-five chronic post-stroke long duration hemiparetic patients who had Ashworth grade 1-2 spasticity at affected calf muscles and lower limb Brunnstrom stage 2-3 and also able to walk independently without an assistive device. Berg Balance Scale (BERG), and the postural stability test (PST) and the fall risk test (FRT) of Biodex balance systems were used for the assessments. All of the patients were assessed with AFO and without AFO. All assessments were made with footwear. The mean post-stroke duration was 20,32±7,46 months. The BERG scores were 42,12±9,05 without AFO and 47,52±7,77 with AFO; the overall stability scores of FRT were 3,35±1,97 without AFO and 2,69±1,65 with AFO (Pbalance and provide fall risk reduction in chronic post-stroke ambulatory hemiparetic patients who had mild to moderate spasticity on their affected lower limb. These results encourage the usage of AFO on long duration hemiparetic patients in order to provide better balance and lesser fall risk.

  15. Time contour expression of limited range phenomena on stack chart; Jugo chart jo deno kyokuchi gensho jikan contour

    Energy Technology Data Exchange (ETDEWEB)

    Kametani, T

    1997-05-27

    Time contour expression of limited range phenomena on stack chart is examined for further improvement on the result of the ultimate interpretation in the seismic reflection survey. The policy is made clear from the beginning that local phenomena are to be discussed, and data prior CMP stacking is interpreted in detail. For this purpose, it is effective to make use of the time contour expression in the midpoint-offset plane simultaneously with the CMP and COP panels. For the review of data prior to CMP stacking, it is convenient to use the CMP (CDP) stacking chart in which the data is arranged methodically. In this chart, all the channels which are crude data prior to stacking are plotted on midpoint-offset coordinates, which plane is called the MOD (Midpoint Offset Domain) panel. Various panels can be chosen unrestrictedly, and their mutual relations can be easily grasped. When data points are given a time axis, they can be expressed in a time contour. Studies are conducted about the underground structure, multiple reflection paths divided by it, and characteristics of detour reflection attributable to faults. 4 refs., 9 figs.

  16. Narrative review: Diabetic foot and infrared thermography

    Science.gov (United States)

    Hernandez-Contreras, D.; Peregrina-Barreto, H.; Rangel-Magdaleno, J.; Gonzalez-Bernal, J.

    2016-09-01

    Diabetic foot is one of the major complications experienced by diabetic patients. An early identification and appropriate treatment of diabetic foot problems can prevent devastating consequences such as limb amputation. Several studies have demonstrated that temperature variations in the plantar region can be related to diabetic foot problems. Infrared thermography has been successfully used to detect complication related to diabetic foot, mainly because it is presented as a rapid, non-contact and non-invasive technique to visualize the temperature distribution of the feet. In this review, an overview of studies that relate foot temperature with diabetic foot problems through infrared thermography is presented. Through this research, it can be appreciated the potential of infrared thermography and the benefits that this technique present in this application. This paper also presents the different methods for thermogram analysis and the advantages and disadvantages of each one, being the asymmetric analysis the method most used so far.

  17. Diabetes: Good Diabetes Management and Regular Foot Care Help Prevent Severe Foot Sores

    Science.gov (United States)

    Amputation and diabetes: How to protect your feet Good diabetes management and regular foot care help prevent severe foot sores that ... and may require amputation. By Mayo Clinic Staff Diabetes complications can include nerve damage and poor blood ...

  18. Pancreatic gross tumor volume contouring on computed tomography (CT) compared with magnetic resonance imaging (MRI): Results of an international contouring conference.

    Science.gov (United States)

    Hall, William A; Heerkens, Hanne D; Paulson, Eric S; Meijer, Gert J; Kotte, Alexis N; Knechtges, Paul; Parikh, Parag J; Bassetti, Michael F; Lee, Percy; Aitken, Katharine L; Palta, Manisha; Myrehaug, Sten; Koay, Eugene J; Portelance, Lorraine; Ben-Josef, Edgar; Erickson, Beth A

    Accurate identification of the gross tumor volume (GTV) in pancreatic adenocarcinoma is challenging. We sought to understand differences in GTV delineation using pancreatic computed tomography (CT) compared with magnetic resonance imaging (MRI). Twelve attending radiation oncologists were convened for an international contouring symposium. All participants had a clinical and research interest in pancreatic adenocarcinoma. CT and MRI scans from 3 pancreatic cases were used for contouring. CT and MRI GTVs were analyzed and compared. Interobserver variability was compared using Dice's similarity coefficient (DSC), Hausdorff distances, and Jaccard indices. Mann-Whitney tests were used to check for significant differences. Consensus contours on CT and MRI scans and constructed count maps were used to visualize the agreement. Agreement regarding the optimal method to determine GTV definition using MRI was reached. Six contour sets (3 from CT and 3 from MRI) were obtained and compared for each observer, totaling 72 contour sets. The mean volume of contours on CT was significantly larger at 57.48 mL compared with a mean of 45.76 mL on MRI, P = .011. The standard deviation obtained from the CT contours was significantly larger than the standard deviation from the MRI contours (P = .027). The mean DSC was 0.73 for the CT and 0.72 for the MRI (P = .889). The conformity index measurement was similar for CT and MRI (P = .58). Count maps were created to highlight differences in the contours from CT and MRI. Using MRI as a primary image set to define a pancreatic adenocarcinoma GTV resulted in smaller contours compared with CT. No differences in DSC or the conformity index were seen between MRI and CT. A stepwise method is recommended as an approach to contour a pancreatic GTV using MRI. Copyright © 2017 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  19. A review of methods of analysis in contouring studies for radiation oncology

    International Nuclear Information System (INIS)

    Jameson, Michael G.; Holloway, Lois C.; Metcalfe, Peter E.; Vial, Philip J.; Vinod, Shalini K.

    2010-01-01

    Full text: Inter-observer variability in anatomical contouring is the biggest contributor to uncertainty in radiation treatment planning. Contouring studies are frequently performed to investigate the differences between multiple contours on common datasets. There is, however, no widely accepted method for contour comparisons. The purpose of this study is to review the literature on contouring studies in the context of radiation oncology, with particular consideration of the contouring comparison methods they employ. A literature search, not limited by date, was conducted using Medline and Google Scholar with key words; contour, variation, delineation, inter/intra observer, uncertainty and trial dummy-run. This review includes a description of the contouring processes and contour comparison metrics used. The use of different processes and metrics according to tumour site and other factors were also investigated with limitations described. A total of 69 relevant studies were identified. The most common tumour sites were prostate (26), lung (10), head and neck cancers (8) and breast (7).The most common metric of comparison was volume used 59 times, followed by dimension and shape used 36 times, and centre of volume used 19 times. Of all 69 publications, 67 used a combination of metrics and two used only one metric for comparison. No clear relationships between tumour site or any other factors that may in Auence the contouring process and the metrics used to compare contours were observed from the literature. Further studies are needed to assess the advantages and disadvantages of each metric in various situations.

  20. Consensus Recommendations for Radiation Therapy Contouring and Treatment of Vulvar Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, David K., E-mail: david.gaffney@hci.utah.edu [Department of Radiation Oncology, Huntsman Cancer Hospital, Salt Lake City, Utah (United States); King, Bronwyn [Department of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre and Epworth Radiation Oncology, Melbourne, Victoria (Australia); Viswanathan, Akila N. [Department of Radiation Oncology, Dana-Farber/Brigham and Women' s Cancer Center, Harvard Medical School, Boston, Massachusetts (United States); Barkati, Maroie [Department of Radiation Oncology, Centre hospitalier de l' universite de Montreal, Montreal, Quebec (Canada); Beriwal, Sushil [Department of Radiation Oncology, University of Pittsburgh Cancer Institute, Pittsburgh, Pennsylvania (United States); Eifel, Patricia [Department of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas (United States); Erickson, Beth [Department of Radiation Oncology, Proedtert and Medical College Clinical Cancer Center, Milwaukee, Wisconsin (United States); Fyles, Anthony [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Goulart, Jennifer [Department of Radiation Oncology, British Columbia Cancer Agency, Victoria, British Columbia (Canada); Harkenrider, Matthew [Department of Radiation Oncology, Stritch School of Medicine, Loyola University, Maywood, Illinois (United States); Jhingran, Anuja; Klopp, Ann [Department of Radiation Oncology, MD Anderson Cancer Center, Houston, Texas (United States); Koh, Wui-Jin [Department of Radiation Oncology, University of Washington, Seattle, Washington (United States); Lim, Karen [Liverpool Cancer Therapy Centre, Radiation Oncology Unit, Sydney, New South Wales (Australia); Petersen, Ivy [Department of Radiation Oncology, Mayo Clinic, Rochester, Minnesota (United States); Portelance, Lorraine [Radiation Oncology Department, Miller School of Medicine, University of Miami, Miami, Florida (United States); and others

    2016-07-15

    Purpose: The purpose of this study was to develop a radiation therapy (RT) contouring atlas and recommendations for women with postoperative and locally advanced vulvar carcinoma. Methods and Materials: An international committee of 35 expert gynecologic radiation oncologists completed a survey of the treatment of vulvar carcinoma. An initial set of recommendations for contouring was discussed and generated by consensus. Two cases, 1 locally advanced and 1 postoperative, were contoured by 14 physicians. Contours were compared and analyzed using an expectation-maximization algorithm for simultaneous truth and performance level estimation (STAPLE), and a 95% confidence interval contour was developed. The level of agreement among contours was assessed using a kappa statistic. STAPLE contours underwent full committee editing to generate the final atlas consensus contours. Results: Analysis of the 14 contours showed substantial agreement, with kappa statistics of 0.69 and 0.64 for cases 1 and 2, respectively. There was high specificity for both cases (≥99%) and only moderate sensitivity of 71.3% and 64.9% for cases 1 and 2, respectively. Expert review and discussion generated consensus recommendations for contouring target volumes and treatment for postoperative and locally advanced vulvar cancer. Conclusions: These consensus recommendations for contouring and treatment of vulvar cancer identified areas of complexity and controversy. Given the lack of clinical research evidence in vulvar cancer radiation therapy, the committee advocates a conservative and consistent approach using standardized recommendations.

  1. Consensus Recommendations for Radiation Therapy Contouring and Treatment of Vulvar Carcinoma

    International Nuclear Information System (INIS)

    Gaffney, David K.; King, Bronwyn; Viswanathan, Akila N.; Barkati, Maroie; Beriwal, Sushil; Eifel, Patricia; Erickson, Beth; Fyles, Anthony; Goulart, Jennifer; Harkenrider, Matthew; Jhingran, Anuja; Klopp, Ann; Koh, Wui-Jin; Lim, Karen; Petersen, Ivy; Portelance, Lorraine

    2016-01-01

    Purpose: The purpose of this study was to develop a radiation therapy (RT) contouring atlas and recommendations for women with postoperative and locally advanced vulvar carcinoma. Methods and Materials: An international committee of 35 expert gynecologic radiation oncologists completed a survey of the treatment of vulvar carcinoma. An initial set of recommendations for contouring was discussed and generated by consensus. Two cases, 1 locally advanced and 1 postoperative, were contoured by 14 physicians. Contours were compared and analyzed using an expectation-maximization algorithm for simultaneous truth and performance level estimation (STAPLE), and a 95% confidence interval contour was developed. The level of agreement among contours was assessed using a kappa statistic. STAPLE contours underwent full committee editing to generate the final atlas consensus contours. Results: Analysis of the 14 contours showed substantial agreement, with kappa statistics of 0.69 and 0.64 for cases 1 and 2, respectively. There was high specificity for both cases (≥99%) and only moderate sensitivity of 71.3% and 64.9% for cases 1 and 2, respectively. Expert review and discussion generated consensus recommendations for contouring target volumes and treatment for postoperative and locally advanced vulvar cancer. Conclusions: These consensus recommendations for contouring and treatment of vulvar cancer identified areas of complexity and controversy. Given the lack of clinical research evidence in vulvar cancer radiation therapy, the committee advocates a conservative and consistent approach using standardized recommendations.

  2. Sex-related differences in foot shape.

    Science.gov (United States)

    Krauss, I; Grau, S; Mauch, M; Maiwald, C; Horstmann, T

    2008-11-01

    The purpose of the study was to investigate sex-related differences in foot morphology. In total, 847 subjects were scanned using a 3-D-footscanner. Three different analysis methods were used: (1) comparisons were made for absolute foot measures within 250-270 mm foot length (FL); (2) and for averaged measures (% FL) across all sizes; (3) the feet were then classified using a cluster analysis. Within 250-270 mm FL, male feet were wider and higher (mean differences (MD) 1.3-5.9 mm). No relevant sex-related differences could be found in the comparison of averaged measures (MD 0.3-0.6% FL). Foot types were categorised into voluminous, flat-pointed and slender. Shorter feet were more often voluminous, longer feet were more likely to be narrow and flat. However, the definition of 'short' and 'long' was sex-related; thus, allometry of foot measures was different. For shoe design, measures should be derived for each size and sex separately. Different foot types should be considered to account for the variety in foot shape. Improper footwear can cause foot pain and deformity. Therefore, knowledge of sex-related differences in foot measures is important to assist proper shoe fit in both men and women. The present study supplements the field of knowledge within this context with recommendations for the manufacturing of shoes.

  3. Introduction of hind foot coronal alignment view

    International Nuclear Information System (INIS)

    Moon, Il Bong; Jeon, Ju Seob; Yoon, Kang Cheol; Choi, Nam Kil; Kim, Seung Kook

    2006-01-01

    Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hind foot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hind foot coronal alignment view. Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. Both feet stood on a radiolucent platform with equal weight on both feet. Both feet are located foot axis longitudinal perpendicular to the platform. Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. The x-ray beam is angled down approximately 15 .deg. to 20 .deg. This image described tibial axis and medial, lateral tuberosity of calcaneus. Calcaneus do not rotated. The view is showed by talotibial joint space. Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hind foot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hind foot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hind foot and varus, valgus deformity of calcaneus

  4. The Glasgow-Maastricht foot model, evaluation of a 26 segment kinematic model of the foot

    OpenAIRE

    Oosterwaal, Michiel; Carbes, Sylvain; Telfer, Scott; Woodburn, James; T?rholm, S?ren; Al-Munajjed, Amir A.; van Rhijn, Lodewijk; Meijer, Kenneth

    2016-01-01

    Background Accurately measuring of intrinsic foot kinematics using skin mounted markers is difficult, limited in part by the physical dimensions of the foot. Existing kinematic foot models solve this problem by combining multiple bones into idealized rigid segments. This study presents a novel foot model that allows the motion of the 26 bones to be individually estimated via a combination of partial joint constraints and coupling the motion of separate joints using kinematic rhythms. Methods ...

  5. A review of the biomechanics of the diabetic foot

    NARCIS (Netherlands)

    van Schie, C. H. M.

    2005-01-01

    In general, diabetic foot ulcers result from abnormal mechanical loading of the foot, such as repetitive moderate pressure applied to the plantar aspect of the foot while walking. Diabetic peripheral neuropathy causes changes in foot structure, affecting foot function and subsequently leading to

  6. Stress Fractures of the Foot.

    Science.gov (United States)

    Hossain, Munier; Clutton, Juliet; Ridgewell, Mark; Lyons, Kathleen; Perera, Anthony

    2015-10-01

    Stress fractures of the foot and ankle may be more common among athletes than previously reported. A low threshold for investigation is warranted and further imaging may be appropriate if initial radiographs remain inconclusive. Most of these fractures can be treated conservatively with a period of non-weight-bearing mobilization followed by gradual return to activity. Early surgery augmented by bone graft may allow athletes to return to sports earlier. Risk of delayed union, nonunion, and recurrent fracture is high. Many of the patients may also have risk factors for injury that should be modified for a successful outcome. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Overuse syndromes of the foot

    International Nuclear Information System (INIS)

    Kainberger, F.; Peloschek, P.; Weidekamm, C.; Uffmann, M.

    2007-01-01

    Overuse syndromes due to lifestyle problems or sporting activities commonly lead to foot abnormalities. The tendons of the long flexor and extensor muscles are specifically prone to degeneration. The various disorders may be classified by a grading system that includes peritendinous inflammation, degenerative tendon disease, and ruptures. Bone marrow edema is another typical manifestation of overuse. It may be differentiated from inflammatory or traumatic forms of edema by its anatomic distribution. Systematic pattern recognition is based on the concept of musculotendinous and osseous kinetic chains. (orig.) [de

  8. Assessment of signs of foot infection in diabetes patients using photographic foot imaging and infrared thermography

    NARCIS (Netherlands)

    Hazenberg, Constantijn E. V. B.; van Netten, Jaap J.; van Baal, Sjef G.; Bus, Sicco A.

    2014-01-01

    Patients with diabetic foot disease require frequent screening to prevent complications and may be helped through telemedical home monitoring. Within this context, the goal was to determine the validity and reliability of assessing diabetic foot infection using photographic foot imaging and infrared

  9. A new method to normalize plantar pressure measurements for foot size and foot progression angle.

    NARCIS (Netherlands)

    Keijsers, N.L.; Stolwijk, N.M.; Nienhuis, B.; Duysens, J.E.J.

    2009-01-01

    Plantar pressure measurement provides important information about the structure and function of the foot and is a helpful tool to evaluate patients with foot complaints. In general, average and maximum plantar pressure of 6-11 areas under the foot are used to compare groups of subjects. However,

  10. Repeatability of the Oxford Foot Model in children with foot deformity

    NARCIS (Netherlands)

    McCahill, Jennifer; Stebbins, Julie; Koning, Bart; Harlaar, Jaap; Theologis, Tim

    Introduction The Oxford Foot Model (OFM) is a multi-segment, kinematic model developed to assess foot motion. It has previously been assessed for repeatability in healthy populations. To determine the OFM's reliability for detecting foot deformity, it is important to know repeatability in

  11. The effectiveness of non-surgical intervention (Foot Orthoses for paediatric flexible pes planus: A systematic review: Update.

    Directory of Open Access Journals (Sweden)

    Sindhrani Dars

    Full Text Available Flexible pes planus (flat feet in children is a common presenting condition in clinical practice due to concerns amongst parents and caregivers. While Foot Orthoses (FOs are a popular intervention, their effectiveness remains unclear. Thus, the aim of this systematic review was to update the current evidence base for the effectiveness of FOs for paediatric flexible pes planus.A systematic search of electronic databases (Cochrane, Medline, AMED, EMBASE, CINHAL, SportDiscus, Scopus and PEDro was conducted from January 2011 to July 2017. Studies of children (0-18 years diagnosed with flexible pes planus and intervention to be any type of Foot Orthoses (FOs were included. This review was conducted and reported in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA statement. McMaster critical review form for quantitative studies, was used to assess the methodological quality of the included studies. Given the heterogeneity of the included studies, a descriptive synthesis of the included studies was undertaken.Out of 606 articles identified, 11 studies (three RCTs; two case-controls; five case-series and one single case study met the inclusion criteria. A diverse range of pre-fabricated and customised FOs were utilised and effectiveness measured through a plethora of outcomes. Summarised findings from the heterogeneous evidence base indicated that FOs may have a positive impact across a range of outcomes including pain, foot posture, gait, function and structural and kinetic measures. Despite these consistent positive outcomes reported in several studies, the current evidence base lacks clarity and uniformity in terms of diagnostic criteria, interventions delivered and outcomes measured for paediatric flexible pes planus.There continues to remain uncertainty on the effectiveness of FOs for paediatric flexible pes planus. Despite a number of methodological limitations, FOs show potential as a treatment method for

  12. Anatomically contoured plates for fixation of rib fractures.

    Science.gov (United States)

    Bottlang, Michael; Helzel, Inga; Long, William B; Madey, Steven

    2010-03-01

    : Intraoperative contouring of long bridging plates for stabilization of flail chest injuries is difficult and time consuming. This study implemented for the first time biometric parameters to derive anatomically contoured rib plates. These plates were tested on a range of cadaveric ribs to quantify plate fit and to extract a best-fit plating configuration. : Three left and three right rib plates were designed, which accounted for anatomic parameters required when conforming a plate to the rib surface. The length lP over which each plate could trace the rib surface was evaluated on 109 cadaveric ribs. For each rib level 3-9, the plate design with the highest lP value was extracted to determine a best-fit plating configuration. Furthermore, the characteristic twist of rib surfaces was measured on 49 ribs to determine the surface congruency of anatomic plates with a constant twist. : The tracing length lP of the best-fit plating configuration ranged from 12.5 cm to 14.7 cm for ribs 3-9. The corresponding range for standard plates was 7.1-13.7 cm. The average twist of ribs over 8-cm, 12-cm, and 16-cm segments was 8.3 degrees, 20.6 degrees, and 32.7 degrees, respectively. The constant twist of anatomic rib plates was not significantly different from the average rib twist. : A small set of anatomic rib plates can minimize the need for intraoperative plate contouring for fixation of ribs 3-9. Anatomic rib plates can therefore reduce the time and complexity of flail chest stabilization and facilitate spanning of flail segments with long plates.

  13. Prefabrication of 3D cartilage contructs: towards a tissue engineered auricle--a model tested in rabbits.

    Directory of Open Access Journals (Sweden)

    Achim von Bomhard

    Full Text Available The reconstruction of an auricle for congenital deformity or following trauma remains one of the greatest challenges in reconstructive surgery. Tissue-engineered (TE three-dimensional (3D cartilage constructs have proven to be a promising option, but problems remain with regard to cell vitality in large cell constructs. The supply of nutrients and oxygen is limited because cultured cartilage is not vascular integrated due to missing perichondrium. The consequence is necrosis and thus a loss of form stability. The micro-surgical implantation of an arteriovenous loop represents a reliable technology for neovascularization, and thus vascular integration, of three-dimensional (3D cultivated cell constructs. Auricular cartilage biopsies were obtained from 15 rabbits and seeded in 3D scaffolds made from polycaprolactone-based polyurethane in the shape and size of a human auricle. These cartilage cell constructs were implanted subcutaneously into a skin flap (15 × 8 cm and neovascularized by means of vascular loops implanted micro-surgically. They were then totally enhanced as 3D tissue and freely re-implanted in-situ through microsurgery. Neovascularization in the prefabricated flap and cultured cartilage construct was analyzed by microangiography. After explantation, the specimens were examined by histological and immunohistochemical methods. Cultivated 3D cartilage cell constructs with implanted vascular pedicle promoted the formation of engineered cartilaginous tissue within the scaffold in vivo. The auricles contained cartilage-specific extracellular matrix (ECM components, such as GAGs and collagen even in the center oft the constructs. In contrast, in cultivated 3D cartilage cell constructs without vascular pedicle, ECM distribution was only detectable on the surface compared to constructs with vascular pedicle. We demonstrated, that the 3D flaps could be freely transplanted. On a microangiographic level it was evident that all the skin flaps

  14. Gallbladder Boundary Segmentation from Ultrasound Images Using Active Contour Model

    Science.gov (United States)

    Ciecholewski, Marcin

    Extracting the shape of the gallbladder from an ultrasonography (US) image allows superfluous information which is immaterial in the diagnostic process to be eliminated. In this project an active contour model was used to extract the shape of the gallbladder, both for cases free of lesions, and for those showing specific disease units, namely: lithiasis, polyps and changes in the shape of the organ, such as folds or turns of the gallbladder. The approximate shape of the gallbladder was found by applying the motion equation model. The tests conducted have shown that for the 220 US images of the gallbladder, the area error rate (AER) amounted to 18.15%.

  15. Classification of diabetic foot ulcers.

    Science.gov (United States)

    Game, Frances

    2016-01-01

    It is known that the relative importance of factors involved in the development of diabetic foot problems can vary in both their presence and severity between patients and lesions. This may be one of the reasons why outcomes seem to vary centre to centre and why some treatments may seem more effective in some people than others. There is a need therefore to classify and describe lesions of the foot in patients with diabetes in a manner that is agreed across all communities but is simple to use in clinical practice. No single system is currently in widespread use, although a number have been published. Not all are well validated outside the system from which they were derived, and it has not always been made clear the clinical purposes to which such classifications should be put to use, whether that be for research, clinical description in routine clinical care or audit. Here the currently published classification systems, their validation in clinical practice, whether they were designed for research, audit or clinical care, and the strengths and weaknesses of each are explored. Copyright © 2016 John Wiley & Sons, Ltd.

  16. Preventative foot care in people with diabetes: Quality patient ...

    African Journals Online (AJOL)

    Keywords: preventative foot care; diabetes; risk stratification: self care. Introduction ... diabetes is considered to be a key indicator of the quality of foot ... loss of protective sensation, the importance of foot monitoring on a daily basis, the proper ...

  17. The role of shape complexity in the detection of closed contours.

    Science.gov (United States)

    Wilder, John; Feldman, Jacob; Singh, Manish

    2016-09-01

    The detection of contours in noise has been extensively studied, but the detection of closed contours, such as the boundaries of whole objects, has received relatively little attention. Closed contours pose substantial challenges not present in the simple (open) case, because they form the outlines of whole shapes and thus take on a range of potentially important configural properties. In this paper we consider the detection of closed contours in noise as a probabilistic decision problem. Previous work on open contours suggests that contour complexity, quantified as the negative log probability (Description Length, DL) of the contour under a suitably chosen statistical model, impairs contour detectability; more complex (statistically surprising) contours are harder to detect. In this study we extended this result to closed contours, developing a suitable probabilistic model of whole shapes that gives rise to several distinct though interrelated measures of shape complexity. We asked subjects to detect either natural shapes (Exp. 1) or experimentally manipulated shapes (Exp. 2) embedded in noise fields. We found systematic effects of global shape complexity on detection performance, demonstrating how aspects of global shape and form influence the basic process of object detection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. 29 CFR 1918.104 - Foot protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Foot protection. 1918.104 Section 1918.104 Labor... following consensus standards: (i) ASTM F-2412-2005, “Standard Test Methods for Foot Protection,” and ASTM F... footwear that is constructed in accordance with one of the above consensus standards will be deemed to be...

  19. VACUUM ASSISTED CLOSURE IN DIABETIC FOOT MANAGEMENT

    OpenAIRE

    Moganakannan; `Prema; Arun Sundara Rajan

    2014-01-01

    Comparision of vacuum assisted closure vs conventional dressing in management of diabetic foot patients. 30 patients were taken in that 15 underwent vacuum therapy and remaining 15 underwent conventional dressing.They were analysed by the development of granulation tissue and wound healing.The study showed Vac therapy is the best modality for management of diabetic foot patients.

  20. Cosmetic Foot Surgery: Fashion's Pandora's Box

    Science.gov (United States)

    ... Fashion’s Pandora’s Box? A A A | Print | Share Cosmetic Foot Surgery: Fashion’s Pandora’s Box? Foot and ankle ... extreme and imprudent as it may sound, the cosmetic surgery craze is not just for faces anymore— ...

  1. Preventing Diabetic Foot Complications : Strategic Recommendations

    African Journals Online (AJOL)

    The diabetic foot is the commonest cause of non-traumatic lower extremity amputation in the developed and developing nations. Several risk factors predispose the diabetic patient to foot ulceration and peripheral neuropathy, with peripheral vascular disease are the commonest risk factors. Clinical examination for these risk ...

  2. Contoured-gap coaxial guns for imploding plasma liner experiments

    Science.gov (United States)

    Witherspoon, F. D.; Case, A.; Brockington, S.; Cassibry, J. T.; Hsu, S. C.

    2014-10-01

    Arrays of supersonic, high momentum flux plasma jets can be used as standoff compression drivers for generating spherically imploding plasma liners for driving magneto-inertial fusion, hence the name plasma-jet-driven MIF (PJMIF). HyperV developed linear plasma jets for the Plasma Liner Experiment (PLX) at LANL where two guns were successfully tested. Further development at HyperV resulted in achieving the PLX goal of 8000 μg at 50 km/s. Prior work on contoured-gap coaxial guns demonstrated an approach to control the blowby instability and achieved substantial performance improvements. For future plasma liner experiments we propose to use contoured-gap coaxial guns with small Minirailgun injectors. We will describe such a gun for a 60-gun plasma liner experiment. Discussion topics will include impurity control, plasma jet symmetry and topology (esp. related to uniformity and compactness), velocity capability, and techniques planned for achieving gun efficiency of >50% using tailored impedance matched pulse forming networks. Mach2 and UAH SPH code simulations will be included. Work supported by US DOE DE-FG02-05ER54810.

  3. Automated identification of the lung contours in positron emission tomography

    International Nuclear Information System (INIS)

    Nery, F; Ferreira, N C; Faustino, R; Silva, J Silvestre; Caramelo, F J

    2013-01-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging technique that permits to analyze, in three dimensions, the physiological processes in vivo. One of the areas where PET has demonstrated its advantages is in the staging of lung cancer, where it offers better sensitivity and specificity than other techniques such as CT. On the other hand, accurate segmentation, an important procedure for Computer Aided Diagnostics (CAD) and automated image analysis, is a challenging task given the low spatial resolution and the high noise that are intrinsic characteristics of PET images. This work presents an algorithm for the segmentation of lungs in PET images, to be used in CAD and group analysis in a large patient database. The lung boundaries are automatically extracted from a PET volume through the application of a marker-driven watershed segmentation procedure which is robust to the noise. In order to test the effectiveness of the proposed method, we compared the segmentation results in several slices using our approach with the results obtained from manual delineation. The manual delineation was performed by nuclear medicine physicians that used a software routine that we developed specifically for this task. To quantify the similarity between the contours obtained from the two methods, we used figures of merit based on region and also on contour definitions. Results show that the performance of the algorithm was similar to the performance of human physicians. Additionally, we found that the algorithm-physician agreement is similar (statistically significant) to the inter-physician agreement.

  4. Gestalten of today: early processing of visual contours and surfaces.

    Science.gov (United States)

    Kovács, I

    1996-12-01

    While much is known about the specialized, parallel processing streams of low-level vision that extract primary visual cues, there is only limited knowledge about the dynamic interactions between them. How are the fragments, caught by local analyzers, assembled together to provide us with a unified percept? How are local discontinuities in texture, motion or depth evaluated with respect to object boundaries and surface properties? These questions are presented within the framework of orientation-specific spatial interactions of early vision. Key observations of psychophysics, anatomy and neurophysiology on interactions of various spatial and temporal ranges are reviewed. Aspects of the functional architecture and possible neural substrates of local orientation-specific interactions are discussed, underlining their role in the integration of information across the visual field, and particularly in contour integration. Examples are provided demonstrating that global context, such as contour closure and figure-ground assignment, affects these local interactions. It is illustrated that figure-ground assignment is realized early in visual processing, and that the pattern of early interactions also brings about an effective and sparse coding of visual shape. Finally, it is concluded that the underlying functional architecture is not only dynamic and context dependent, but the pattern of connectivity depends as much on past experience as on actual stimulation.

  5. Lymph node segmentation by dynamic programming and active contours.

    Science.gov (United States)

    Tan, Yongqiang; Lu, Lin; Bonde, Apurva; Wang, Deling; Qi, Jing; Schwartz, Lawrence H; Zhao, Binsheng

    2018-03-03

    Enlarged lymph nodes are indicators of cancer staging, and the change in their size is a reflection of treatment response. Automatic lymph node segmentation is challenging, as the boundary can be unclear and the surrounding structures complex. This work communicates a new three-dimensional algorithm for the segmentation of enlarged lymph nodes. The algorithm requires a user to draw a region of interest (ROI) enclosing the lymph node. Rays are cast from the center of the ROI, and the intersections of the rays and the boundary of the lymph node form a triangle mesh. The intersection points are determined by dynamic programming. The triangle mesh initializes an active contour which evolves to low-energy boundary. Three radiologists independently delineated the contours of 54 lesions from 48 patients. Dice coefficient was used to evaluate the algorithm's performance. The mean Dice coefficient between computer and the majority vote results was 83.2%. The mean Dice coefficients between the three radiologists' manual segmentations were 84.6%, 86.2%, and 88.3%. The performance of this segmentation algorithm suggests its potential clinical value for quantifying enlarged lymph nodes. © 2018 American Association of Physicists in Medicine.

  6. Limited capacity for contour curvature in iconic memory.

    Science.gov (United States)

    Sakai, Koji

    2006-06-01

    We measured the difference threshold for contour curvature in iconic memory by using the cued discrimination method. The study stimulus consisting of 2 to 6 curved contours was briefly presented in the fovea, followed by two lines as cues. Subjects discriminated the curvature of two cued curves. The cue delays were 0 msec. and 300 msec. in Exps. 1 and 2, respectively, and 50 msec. before the study offset in Exp. 3. Analysis of data from Exps. 1 and 2 showed that the Weber fraction rose monotonically with the increase in set size. Clear set-size effects indicate that iconic memory has a limited capacity. Moreover, clear set-size effect in Exp. 3 indicates that perception itself has a limited capacity. Larger set-size effects in Exp. 1 than in Exp. 3 suggest that iconic memory after perceptual process has limited capacity. These properties of iconic memory at threshold level are contradictory to the traditional view that iconic memory has a high capacity both at suprathreshold and categorical levels.

  7. Functional Contour-following via Haptic Perception and Reinforcement Learning.

    Science.gov (United States)

    Hellman, Randall B; Tekin, Cem; van der Schaar, Mihaela; Santos, Veronica J

    2018-01-01

    Many tasks involve the fine manipulation of objects despite limited visual feedback. In such scenarios, tactile and proprioceptive feedback can be leveraged for task completion. We present an approach for real-time haptic perception and decision-making for a haptics-driven, functional contour-following task: the closure of a ziplock bag. This task is challenging for robots because the bag is deformable, transparent, and visually occluded by artificial fingertip sensors that are also compliant. A deep neural net classifier was trained to estimate the state of a zipper within a robot's pinch grasp. A Contextual Multi-Armed Bandit (C-MAB) reinforcement learning algorithm was implemented to maximize cumulative rewards by balancing exploration versus exploitation of the state-action space. The C-MAB learner outperformed a benchmark Q-learner by more efficiently exploring the state-action space while learning a hard-to-code task. The learned C-MAB policy was tested with novel ziplock bag scenarios and contours (wire, rope). Importantly, this work contributes to the development of reinforcement learning approaches that account for limited resources such as hardware life and researcher time. As robots are used to perform complex, physically interactive tasks in unstructured or unmodeled environments, it becomes important to develop methods that enable efficient and effective learning with physical testbeds.

  8. Ultrasound cavitation versus cryolipolysis for non-invasive body contouring.

    Science.gov (United States)

    Mahmoud ELdesoky, Mohamed Taher; Mohamed Abutaleb, Enas ELsayed; Mohamed Mousa, Gihan Samir

    2015-08-24

    The demand for non-surgical and non-invasive devices is continuous and increasing. Such devices have gradually gained ground in the reduction of localised fat and the improvement of body contouring. The study aimed to compare the effects of ultrasound cavitation and cryolipolysis on localised abdominal fat. In total, 60 participants with a body mass index (BMI) over 30 kg/m 2 , whose age ranged between 25 and 45 years, were included. The participants were randomly assigned to three groups of 20 each, using ultrasound cavitation and diet, cryolipolysis and diet, and diet only (the control group), respectively. Measures were bodyweight, BMI, waist circumference and suprailiac skinfold were measured at the beginning of the study and 2 months later. The three groups showed significant improvements in all measured variables after 2 months. There was no statistically significant difference in bodyweight or in BMI among the groups after treatment. However, the groups using ultrasound cavitation and cryolipolysis showed better post-treatment improvement than the diet-only group in waist circumference and suprailiac skinfold. There was no statistically significant difference post-treatment between the cavitation and cryolipolysis groups in waist circumference or suprailiac skinfold. Both ultrasound cavitation and cryolipolysis are safe and effective for the reduction of abdominal fat thickness and for abdominal contouring. © 2015 The Australasian College of Dermatologists.

  9. The role of foot morphology on foot function in diabetic subjects with or without neuropathy.

    Science.gov (United States)

    Guiotto, Annamaria; Sawacha, Zimi; Guarneri, Gabriella; Cristoferi, Giuseppe; Avogaro, Angelo; Cobelli, Claudio

    2013-04-01

    The aim of this study was to investigate the role of foot morphology, related with respect to diabetes and peripheral neuropathy in altering foot kinematics and plantar pressure during gait. Healthy and diabetic subjects with or without neuropathy with different foot types were analyzed. Three dimensional multisegment foot kinematics and plantar pressures were assessed on 120 feet: 40 feet (24 cavus, 20 with valgus heel and 11 with hallux valgus) in the control group, 80 feet in the diabetic (25 cavus 13 with valgus heel and 13 with hallux valgus) and the neuropathic groups (28 cavus, 24 with valgus heel and 18 with hallux valgus). Subjects were classified according to their foot morphology allowing further comparisons among the subgroups with the same foot morphology. When comparing neuropathic subjects with cavus foot, valgus heel with controls with the same foot morphology, important differences were noticed: increased dorsiflexion and peak plantar pressure on the forefoot (Pfoot morphology in altering both kinematics and plantar pressure in diabetic subjects, diabetes appeared to further contribute in altering foot biomechanics. Surprisingly, all the diabetic subjects with normal foot arch or with valgus hallux were no more likely to display significant differences in biomechanics parameters than controls. This data could be considered a valuable support for future research on diabetic foot function, and in planning preventive interventions. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Reliability and normative values of the foot line test: a technique to assess foot posture

    DEFF Research Database (Denmark)

    Brushøj, C; Larsen, Klaus; Nielsen, MB

    2007-01-01

    STUDY DESIGN: Test-retest reliability. OBJECTIVE: To examine the reliability and report normative values of a novel test, the foot line test (FLT), to describe foot morphology. BACKGROUND: Numerous foot examinations are performed each day, but most existing examination techniques have considerable...... limitations regarding reliability and validity. METHODS: One hundred thirty subjects with mean foot size 44 (41-50 European size) participated. Two examiners, blinded to each other's measurements, measured the right foot of the subjects twice and the left foot once. The position of the most medial aspect...... of the navicular in the mediolateral direction was projected vertically onto a piece of paper placed under the subject's foot, and compared to the position of the forefoot and hindfoot to obtain the FLT value. RESULTS: FLT values ranged from -8 to 14 mm, with a mean (+/-SD) of 3.7 +/- 3.4 mm. The intratester...

  11. Growth factors for treating diabetic foot ulcers

    DEFF Research Database (Denmark)

    Martí-Carvajal, Arturo J; Gluud, Christian; Nicola, Susana

    2015-01-01

    following treatment for diabetic foot ulcers (RR 0.64, 95% CI 0.14 to 2.94; P value 0.56, low quality of evidence)Although 11 trials reported time to complete healing of the foot ulcers in people with diabetes , meta-analysis was not possible for this outcome due to the unique comparisons within each trial...... (minimum of one toe), complete healing of the foot ulcer, and time to complete healing of the diabetic foot ulcer as the primary outcomes. DATA COLLECTION AND ANALYSIS: Independently, we selected randomised clinical trials, assessed risk of bias, and extracted data in duplicate. We estimated risk ratios......BACKGROUND: Foot ulcers are a major complication of diabetes mellitus, often leading to amputation. Growth factors derived from blood platelets, endothelium, or macrophages could potentially be an important treatment for these wounds but they may also confer risks. OBJECTIVES: To assess...

  12. Foot problems in a group of patients with rheumatoid arthritis: an unmet need for foot care.

    Science.gov (United States)

    Borman, Pinar; Ayhan, Figen; Tuncay, Figen; Sahin, Mehtap

    2012-01-01

    The aim of this study was to evaluate the foot involvement in a group of RA patients in regard to symptoms, type and frequency of deformities, location, radiological changes, and foot care. A randomized selected 100 rheumatoid arthritis (RA) patients were recruited to the study. Data about foot symptoms, duration and location of foot pain, pain intensity, access to services related to foot, treatment, orthoses and assistive devices, and usefulness of therapies were determined by the questionnaire. Radiological changes were assessed according to modified Larsen scoring system. The scores of disease activity scale of 28 joints and Health Assessment Questionnaire indicating the functional status of RA patients were collected from patient files. A total of 100 RA patients (90 female, 10 male) with a mean age of 52.5 ±10.9 years were enrolled to the study. Eighty-nine of the 100 patients had experienced foot complaints/symptoms in the past or currently. Foot pain and foot symptoms were reported as the first site of involvement in 14 patients. Thirty-six patients had ankle pain and the most common sites of the foot symptoms were ankle (36%) and forefoot (30%) followed by hindfoot (17%) and midfoot (7%) currently. Forty-nine of the patients described that they had difficulty in performing their foot care. Insoles and orthopedic shoes were prescribed in 39 patients, but only 14 of them continued to use them. The main reasons for not wearing them were; 17 not helpful (43%), 5 made foot pain worse (12.8%), and 3 did not fit (7.6%). Foot symptoms were reported to be decreased in 24 % of the subjects after the medical treatment and 6 patients indicated that they had underwent foot surgery. Current foot pain was significantly associated with higher body mass index and longer disease duration, and duration of morning stiffness. The radiological scores did not correlate with duration of foot symptoms and current foot pain (p>0.05) but the total number of foot deformities was

  13. Design and pilot testing of the DVA/Seattle Footwear System for diabetic patients with foot insensitivity.

    Science.gov (United States)

    Reiber, G E; Smith, D G; Boone, D A; del Aguila, M; Borchers, R E; Mathews, D; Joseph, A W; Burgess, E M

    1997-01-01

    Clinical epidemiology studies suggest the majority of lower limb amputations were preceded by a minor traumatic event, often footwear-related, and lower limb ulcers. To reduce foot trauma and ulcers, the diabetic patient with foot insensitivity has unique footwear needs. To address these needs for patients not requiring custom shoes, the DVA/Seattle Footwear System was developed. The six components of this system include: 1) a specially designed shoe last based on the geometry of the diabetic foot and research findings on foot regions at highest risk of ulceration, 2) a depth-inlay shoe, "Custom Stride by PRS," designed to be paired with either a custom-fabricated cork insole or a preformed polyurethane insole, 3) a laser digitizing system that captures 3-D plantar foot contours, 4) DVA/Seattle ShapeMaker software adaptation for modifying plantar surface contours and applying free-form and template modifications to increase or relieve loading, 5) software that translates files into code used by a milling machine to define the cutting path and carve cork blockers into custom insoles, and 6) a preformed polyurethane insole thicker than a typical insole to accommodate the extra volume and the interior dimensions of the shoe. A 6-month pilot cross-over trial of 24 diabetic male veterans without prior foot ulcers was conducted to determine the feasibility of producing, and the safety of wearing, these depthinlay shoes and both types of insoles. During the first 4 weeks, patients were assigned to the study shoes and one type of insole. During the next 4 weeks, they wore the other type of insole, and during the final 4 months, they chose which pair of insoles to wear with the study shoes. Over 150 person-months of footwear observation revealed no breaks in the cutaneous barrier with use of either cork or polyurethane insoles and the study shoes. Patient compliance with the footwear was 88%. Patients were highly satisfied with the appearance, stability, and comfort of the

  14. Holistic management of diabetic foot

    Science.gov (United States)

    Lindarto, D.

    2018-03-01

    Diabetic foot ulcer (DFU) is the most costly and devastating complication of diabetes mellitus, which affect 15% of diabetic patients during their lifetime. DFUs are complex, chronic wounds, which have a major long-term impact on the morbidity, mortality and quality of patients’ lives. Individuals who develop a DFU are at greater risk of premature death, myocardial infarction and fatal stroke than those without a history of DFU. Unlike other chronic wounds, the development and progression of DFU is often complicated by wideranging diabetic changes, such as neuropathy and vascular disease. The management of DFU should be optimized by using a multidisciplinary team, due to a holistic approach to wound management is required. Based on studies, blood sugar control, wound debridement, advanced dressings and offloading modalities should always be a part of DFU management. Furthermore, surgery to heal chronic ulcer and prevent recurrence should be considered as an essential component of management in some cases.

  15. Hand and foot contamination monitor

    International Nuclear Information System (INIS)

    Jakati, R.K.; Kaptral, R.S.; Ananthkrishnan, T.S.; Pansare, M.G.

    1989-01-01

    In order to make quick measurements of beta and gamma contaminations on hands and feet of personnel working in radioactive environments, hand and foot contamination monitors are widely used. This paper describes such a monitor system designed with Intel 8085 based microcomputer. The monitoring and warning system is designed to perform measurement of activity spread over surface of hands and soles of shoes or feet. Even though the system has many features to aid testing and maintainance operation, it is easy to use for unskilled persons. In order to check the contamination, the person stands on platform and inserts both his hands into detector assemblies thereby actuating the sensing switches. After a preset interval, annunciation of clean or contaminated status is declared by the system. (author)

  16. Relationship between sagittal plane kinematics, foot morphology and vertical forces applied to three regions of the foot

    OpenAIRE

    Hannah, I.; Sawacha, Z.; Guiotto, A.; Mazza, C.

    2016-01-01

    Kinetic analysis of human motion with a multi-segment musculoskeletal foot model requires the distribution of loading applied to the modeled foot segments to be determined. This work thus examines the existence of any correlation between intersegmental foot kinematics, foot morphology, and the distribution of vertical loading in a multi-segment foot model. Gait analysis trials were performed by 20 healthy subjects at a self-selected speed with intersegmental foot joint angles and the distribu...

  17. A Voronoi interior adjacency-based approach for generating a contour tree

    Science.gov (United States)

    Chen, Jun; Qiao, Chaofei; Zhao, Renliang

    2004-05-01

    A contour tree is a good graphical tool for representing the spatial relations of contour lines and has found many applications in map generalization, map annotation, terrain analysis, etc. A new approach for generating contour trees by introducing a Voronoi-based interior adjacency set concept is proposed in this paper. The immediate interior adjacency set is employed to identify all of the children contours of each contour without contour elevations. It has advantages over existing methods such as the point-in-polygon method and the region growing-based method. This new approach can be used for spatial data mining and knowledge discovering, such as the automatic extraction of terrain features and construction of multi-resolution digital elevation model.

  18. Measurement of laser welding pool geometry using a closed convex active contour model

    International Nuclear Information System (INIS)

    Zheng, Rui; Zhang, Pu; Duan, Aiqing; Xiao, Peng

    2014-01-01

    The purpose of this study was to develop a computer vision method to measure geometric parameters of the weld pool in a deep penetration CO 2 laser welding system. Accurate measurement was achieved by removing a huge amount of interference caused by spatter, arc light and plasma to extract the true weld pool contour. This paper introduces a closed convex active contour (CCAC) model derived from the active contour model (snake model), which is a more robust high-level vision method than the traditional low-level vision methods. We made an improvement by integrating an active contour with the information that the weld pool contour is almost a closed convex curve. An effective thresholding method and an improved greedy algorithm are also given to complement the CCAC model. These influences can be effectively removed by using the CCAC model to acquire and measure the weld pool contour accurately and relatively fast. (paper)

  19. Contouring algorithm for two dimensional data- an application to airborne surveys

    International Nuclear Information System (INIS)

    Suryakumar, N.V.; Rohatgi, Savita; Raghuwanshi, S.S.

    1994-01-01

    The paper describes in general the contouring algorithm for two dimensional projection of aeroradiometric data and considers not only irregularly spaced flight lines but also solves the other problems related to voluminous data acquired during the airborne surveys. Several simple logics have been described for drawing the contours using scan method and taking care of annotations, identification marking, geographical locations, map size, contour density for visual distinctness and many such problems which may arise during contouring. The present paper also discusses various possibilities of contour line segments in the mini-grid and the criterion for selection of suitable segments has been described in detail. A novel approach to avoid the crossing of contours or missing data is also briefly discussed. The simplicity of the algorithm is mentioned for its ready implementation or any computer/plotter. (author). 8 refs., 8 figs

  20. A fully automated contour detection algorithm the preliminary step for scatter and attenuation compensation in SPECT

    International Nuclear Information System (INIS)

    Younes, R.B.; Mas, J.; Bidet, R.

    1988-01-01

    Contour detection is an important step in information extraction from nuclear medicine images. In order to perform accurate quantitative studies in single photon emission computed tomography (SPECT) a new procedure is described which can rapidly derive the best fit contour of an attenuated medium. Some authors evaluate the influence of the detected contour on the reconstructed images with various attenuation correction techniques. Most of the methods are strongly affected by inaccurately detected contours. This approach uses the Compton window to redetermine the convex contour: It seems to be simpler and more practical in clinical SPECT studies. The main advantages of this procedure are the high speed of computation, the accuracy of the contour found and the programme's automation. Results obtained using computer simulated and real phantoms or clinical studies demonstrate the reliability of the present algorithm. (orig.)

  1. Prefabricated Vertical Drain (PVD) and Deep Cement Mixing (DCM)/Stiffened DCM (SDCM) techniques for soft ground improvement

    Science.gov (United States)

    Bergado, D. T.; Long, P. V.; Chaiyaput, S.; Balasubramaniam, A. S.

    2018-04-01

    Soft ground improvement techniques have become most practical and popular methods to increase soil strength, soil stiffness and reduce soil compressibility including the soft Bangkok clay. This paper focuses on comparative performances of prefabricated vertical drain (PVD) using surcharge, vacuum and heat preloading as well as the cement-admixed clay of Deep Cement Mixing (DCM) and Stiffened DCM (SDCM) methods. The Vacuum-PVD can increase the horizontal coefficient of consolidation, Ch, resulting in faster rate of settlement at the same magnitudes of settlement compared to Conventional PVD. Several field methods of applying vacuum preloading are also compared. Moreover, the Thermal PVD and Thermal Vacuum PVD can increase further the coefficient of horizontal consolidation, Ch, with the associated reduction of kh/ks values by reducing the drainage retardation effects in the smear zone around the PVD which resulted in faster rates of consolidation and higher magnitudes of settlements. Furthermore, the equivalent smear effect due to non-uniform consolidation is also discussed in addition to the smear due to the mechanical installation of PVDs. In addition, a new kind of reinforced deep mixing method, namely Stiffened Deep Cement Mixing (SDCM) pile is introduced to improve the flexural resistance, improve the field quality control, and prevent unexpected failures of the Deep Cement Mixing (DCM) pile. The SDCM pile consists of DCM pile reinforced with the insertion of precast reinforced concrete (RC) core. The full scale test embankment on soft clay improved by SDCM and DCM piles was also analysed. Numerical simulations using the 3D PLAXIS Foundation finite element software have been done to understand the behavior of SDCM and DCM piles. The simulation results indicated that the surface settlements decreased with increasing lengths of the RC cores, and, at lesser extent, increasing sectional areas of the RC cores in the SDCM piles. In addition, the lateral movements

  2. HABITAR Y TECNOLOGÍA EN LA VIVIENDA PREFABRICADA CONTEMPORÁNEA / Living and technology in the contemporary prefabricated home

    Directory of Open Access Journals (Sweden)

    Carmen Guerra Hoyos

    2012-05-01

    Full Text Available RESUMEN El texto revisa las relaciones entre tecnología, habitar y contexto sociocultural a lo largo del ciclo de lo moderno, indagando en la situación actual de los mismos. Si lo que caracteriza el pensamiento contemporáneo es la comprensión y la revisión del periodo de la modernidad, debemos extender ese procedimiento a la arquitectura si pretendemos integrar las herramientas y las soluciones habitacionales y constructivas de nuestra tradición disciplinar en el presente. Trata de realizar un repaso genealógico que quiere recordar la utilidad y el sentido que términos como cabaña, máquina o caravana, pueden tener para la comprensión de la vivienda prefabricada contemporánea. También se procura el acercamiento a dos casos concretos, la casa de los Eames y el pabellón solar de los Smithson, para explorar la superación de algunas de los problemas básicos detectados en la temática de estudio. Por último, y a modo de conclusiones, se abordan algunas líneas de dilatación en los modos de hacer y pensamiento contemporáneos. SUMMARY The paper reviews the relationship between technology, living and socio–cultural context, during the modern cycle, delving into their current states. If understanding and review of the period of modernity characterize contemporary thought, we must extend this procedure to architecture if we expect to integrate the tools and housing and construction solutions of our disciplinary tradition into the present. A genealogical review is made to recall the utility and meaning that terms such as cabin, machine or caravan may have for understanding the contemporary prefabricated home. Also, two specific cases are approached, the Eames House and the Smithson’s Solar Pavilion, in an effort to explore how some of the basic problems identified in the subject matter are overcome. Finally, some aspects of contemporary methods of production and thought are expanded upon as a conclusion.

  3. Comparação da pressão plantar e dos sintomas osteomusculares por meio do uso de palmilhas customizadas e pré-fabricadas no ambiente de trabalho Comparison of plantar pressure and musculoskeletal symptoms with the use of custom and prefabricated insoles in the work environment

    Directory of Open Access Journals (Sweden)

    Josiane S. Almeida

    2009-12-01

    Full Text Available OBJETIVOS: Comparar os efeitos do uso de dois tipos de palmilhas, customizadas e pré-fabricadas, sobre a descarga plantar de peso e o comportamento de sintomas osteomusculares em trabalhadoras de linha de montagem. MÉTODOS: Ensaio randomizado com 27 mulheres que trabalhavam em postura ortostática estática, com média de idade de 30,3±7,09 e massa de 64,85±13,65 e que apresentavam sintomas osteomusculares. Inicialmente, aplicou-se o Questionário Nórdico de Sintomas Osteomusculares e coletaram-se as pressões plantares pelo sistema de baropodometria computadorizada (FootWork. Posteriormente, a casuística foi dividida em grupo controle (GC, que utilizou palmilha pré-fabricada e grupo intervenção (GI, que usou palmilha customizada de etilvinilacetato (EVA durante oito semanas. Dados baropodométricos foram novamente coletados assim como a reaplicação do questionário. RESULTADOS: Não houve diferença estatística significante na comparação entre grupos e dados baropodométricos. Notou-se, entretanto, mudança de comportamento nas variáveis de descarga em cada momento avaliado, assim como o aumento para as variáveis de média pressão de descarga e pressão plantar máxima (pOBJECTIVES: To compare the effect of the use of custom and prefabricated insoles on the behavior of plantar weight load and musculoskeletal symptoms in assembly line workers. METHODS: A randomized trial was carried out with 27 women who worked in a static standing position and had musculoskeletal symptoms. The mean age was 30.3±7.09 years and the weight 64.85±13.65 Kg. The Nordic Musculoskeletal Questionnaire was administered, and plantar pressure was determined using a computerized baropodometric system (FootWork. The sample was then divided into control group, which wore pre-fabricated insoles, and intervention group, which wore ethylvinylacetate insoles for eight weeks. Baropodometric data were collected and the questionnaire was administered once again

  4. Area of isodensity contours in Gaussian and non-Gaussian fields

    International Nuclear Information System (INIS)

    Ryden, B.S.

    1988-01-01

    The area of isodensity contours in a smoothed density field can be measured by the contour-crossing statistic N1, the number of times per unit length that a line drawn through the density field pierces an isodensity contour. The contour-crossing statistic distinguishes between Gaussian and non-Gaussian fields and provides a measure of the effective slope of the power spectrum. The statistic is easy to apply and can be used on pencil beams and slices as well as on a three-dimensional field. 10 references

  5. Extension of Fourier methods to the calculation of effective depths in heterogeneous media of arbitrary contour

    International Nuclear Information System (INIS)

    Starkschall, G.

    1986-01-01

    The description of patient contours and internal structures by means of truncated Fourier series can be extended to continuous contours of arbitrary shape and location by expressing the x and z Cartesian coordinates of the contour as independent Fourier series in a parameter t. An analytic equation for the intersection of the contour and a ray line is then written as an equation in the parameter t. The equation can be solved using numerical methods yielding the Cartesian coordinates of the intersection point directly

  6. Diabetic Foot Complications Despite Successful Pancreas Transplantation.

    Science.gov (United States)

    Seo, Dong-Kyo; Lee, Ho Seong; Park, Jungu; Ryu, Chang Hyun; Han, Duck Jong; Seo, Sang Gyo

    2017-06-01

    It is known that successful pancreas transplantation enables patients with diabetes to maintain a normal glucose level without insulin and reduces diabetes-related complications. However, we have little information about the foot-specific morbidity in patients who have undergone successful pancreas transplantation. The purpose of this study was to investigate the prevalence and predisposing factors for foot complications after successful pancreas transplantation. This retrospective study included 218 patients (91 males, 127 females) who had undergone pancreas transplantation for diabetes. The mean age was 40.7 (range, 15-76) years. Diabetes type, transplantation type, body mass index, and diabetes duration before transplantation were confirmed. After pancreas transplantation, the occurrence and duration of foot and ankle complications were assessed. Twenty-two patients (10.1%) had diabetic foot complications. Fifteen patients (6.9%) had diabetic foot ulcer and 7 patients (3.2%) had Charcot arthropathy. Three patients had both diabetic foot ulcer and Charcot arthropathy. Three insufficiency fractures (1.4%) were included. Mean time of complications after transplantation was 18.5 (range, 2-77) months. Creatinine level 1 year after surgery was higher in the complication group rather than the noncomplication group ( P = .02). Complications of the foot and ankle still occurred following pancreas transplantation in patients with diabetes. Level III, comparative study.

  7. Building Contour Extraction Based on LiDAR Point Cloud

    Directory of Open Access Journals (Sweden)

    Zhang Xu-Qing

    2017-01-01

    Full Text Available This paper presents a new method for solving the problem of utilizing the LiDAR data to extract the building contour line. For detection of the edge points between the building test points by using the least squares fitting to get the edge line of buildings and give the weight determining of the building of edge line slope depend on the length of the edge line. And then get the weighted mean of the positive and negative slope of the building edge line. Based on the structure of the adjacent edge perpendicular hypothesis, regularization processing to extract the edge of the skeleton line perpendicular. The experiments show that the extracted building edges have the good accuracy and have the good applicability in complex urban areas.

  8. The application of volume-outcome contouring in data warehousing.

    Science.gov (United States)

    Studnicki, James; Berndt, Donald J; Luther, Stephen L; Fisher, John W

    2004-01-01

    Despite a compelling body of published research on the nature of provider volume and clinical outcomes, healthcare executives and policymakers have not managed to develop and implement systems that are useful in directing patients to higher volume providers via selective referral or avoidance. A specialized data warehouse application, utilizing hospital discharge data linked to physician biographical information, allows detailed analysis of physician and hospital volume and the resulting pattern (contour) of related outcomes such as mortality, complications, and medical errors. The approach utilizes a historical repository of hospital discharge data in which the outcomes of interest, important patient characteristics and risk factors used in severity-adjusting of the outcomes are derived from the coding structure of the data.

  9. CT assessment of muscle hypertrophy utilizing automatic contouring techniques

    International Nuclear Information System (INIS)

    Steinbach, L.S.; Block, J.; Steiger, P.W.; Ellis, W.; Morris, J.; Genant, H.K.

    1986-01-01

    Quantitative CT was one method used to assess changes in density and area of thigh muscles in paraplegics before and after aerobic leg training. Muscle density and area were measured from the CT image by an automatic contouring algorithm. In the first three patients, total muscle density increased from 11.5% to 18.3% and area increased from 18.3% to 31.3%. In one patient who did not comply with the exercise regimen, only a 10% increase in muscle density and area was detected. This CT program is valuable in the assessment of composition and alteration of limb musculature in the treatment and follow-up of muscular disorders

  10. High-accuracy contouring using projection moiré

    Science.gov (United States)

    Sciammarella, Cesar A.; Lamberti, Luciano; Sciammarella, Federico M.

    2005-09-01

    Shadow and projection moiré are the oldest forms of moiré to be used in actual technical applications. In spite of this fact and the extensive number of papers that have been published on this topic, the use of shadow moiré as an accurate tool that can compete with alternative devices poses very many problems that go to the very essence of the mathematical models used to obtain contour information from fringe pattern data. In this paper some recent developments on the projection moiré method are presented. Comparisons between the results obtained with the projection method and the results obtained by mechanical devices that operate with contact probes are presented. These results show that the use of projection moiré makes it possible to achieve the same accuracy that current mechanical touch probe devices can provide.

  11. Changes of cartilaginous contour of Legg-Calve-Perthes disease

    International Nuclear Information System (INIS)

    Kumasaka, Yukiko; Watanabe, Hitoshi; Higashihara, Tokuro; Kishimoto, Haruyoshi; Harada, Koushi; Kozuka, Takahiro.

    1991-01-01

    T 1 -weighted MR images of Legg-Calve-Perthes disease (LCPD) were classified into three groups on the basis of radiographic stage, and morphological differentiation for staging was attempted. In the stage of fragmentation, both enlargement and flattening of the cartilaginous contour surrounding the epiphysis could be recognized on MRI, and the growth plate showed more curvature than normal. This produced flattening of the epiphysis in the shape of a crescent. We confirmed these findings using four indices for the measurement of cartilaginous outline, and the stage of avascular necrosis and fragmentation could be clearly differentiated. Cartilaginous deformities on MRI are very useful for differentiating between the stage of avascular necrosis and fragmentation. (author)

  12. Prepolishing on a CNC platform with bound abrasive contour tools

    Science.gov (United States)

    Schoeffler, Adrienne E.; Gregg, Leslie L.; Schoen, John M.; Fess, Edward M.; Hakiel, Michael; Jacobs, Stephen D.

    2003-05-01

    Deterministic microgrinding (DMG) of optical glasses and ceramics is the commercial manufacturing process of choice to shape glass surfaces prior to final finishing. This process employs rigid bound matrix diamond tooling resulting in surface roughness values of 3-5μm peak to valley and 100-400nm rms, as well as mid-spatial frequency tool marks that require subsequent removal in secondary finishing steps. The ability to pre-polish optical surfaces within the grinding platform would reduce final finishing process times. Bound abrasive contour wheels containing cerium oxide, alumina or zirconia abrasives were constructed with an epoxy matrix. The effects of abrasive type, composition, and erosion promoters were examined for tool hardness (Shore D), and tested with commercial optical glasses in an Optipro CNC grinding platform. Metrology protocols were developed to examine tool wear and subsequent surface roughness. Work is directed to demonstrating effective material removal, improved surface roughness and cutter mark removal.

  13. Processed bovine cartilage: an improved biosynthetic implant for contour defects

    International Nuclear Information System (INIS)

    Ersek, R.A.; Hart, W.G. Jr.; Greer, D.; Beisang, A.A.; Flynn, P.J.; Denton, D.R.

    1984-01-01

    Irradiated human cartilage has been found to be a superior implant material for correction of contour defects; however, availability problems have prevented this material from gaining wide acceptance. Implantation of processed irradiated bovine cartilage in primates and rabbits, as described here, provides strong evidence that this material performs like irradiated allograft cartilage antigenically and has certain cosmetic advantages over allograft cartilage. Our studies in primates have shown that there is no systemically measurable antibody-antigen reaction, either cellular or noncellular, to irradiated processed bovine cartilage. Neither primary nor second-set provocative implantations produced any measurable rejection. In rabbits, composite grafts of two pieces of irradiated bovine cartilage adjacent to each other were also well tolerated, with no measurable absorption and with capsule formation typical of a foreign body reaction to an inert object

  14. Active contour based segmentation of resected livers in CT images

    Science.gov (United States)

    Oelmann, Simon; Oyarzun Laura, Cristina; Drechsler, Klaus; Wesarg, Stefan

    2015-03-01

    The majority of state of the art segmentation algorithms are able to give proper results in healthy organs but not in pathological ones. However, many clinical applications require an accurate segmentation of pathological organs. The determination of the target boundaries for radiotherapy or liver volumetry calculations are examples of this. Volumetry measurements are of special interest after tumor resection for follow up of liver regrow. The segmentation of resected livers presents additional challenges that were not addressed by state of the art algorithms. This paper presents a snakes based algorithm specially developed for the segmentation of resected livers. The algorithm is enhanced with a novel dynamic smoothing technique that allows the active contour to propagate with different speeds depending on the intensities visible in its neighborhood. The algorithm is evaluated in 6 clinical CT images as well as 18 artificial datasets generated from additional clinical CT images.

  15. Investigation of nozzle contours in the CSIR supersonic wind tunnel

    CSIR Research Space (South Africa)

    Vallabh, Bhavya

    2017-09-01

    Full Text Available Contours in the CSIR Supersonic Wind Tunnel B Vallabha,b and BW Skewsa Received 17 February 2017, in revised form 23 June 2017 and accepted 25 June 2017 R & D Journal of the South African Institution of Mechanical Engineering 2017, 33, 32-41 http... with the Sivells’ nozzle design method and the method of characteristics technique to design the nozzle profiles for the full supersonic Mach number range 𝟏𝟏 ≀ 𝑎𝑎 ≀ 𝟒𝟒.5 of the facility. Automatic computation was used for the profile...

  16. Pair Fermi contour and high-temperature superconductivity

    CERN Document Server

    Belyavsky, V I

    2002-01-01

    The holes superconducting coupling with the pair high summarized pulse and the relative motion low pulses is considered with an account of the quasi-two-dimensional electron structure of the HTSC-cuprates with the clearly-pronounced nesting of the Fermi contour. The superconducting energy gap and the condensation energy are determined and their dependences on the doping level are qualitatively studied. It is shown that the energy gap takes place in some holes concentration area, limited on both sides. The superconducting state, whereby the condensation energy is positive, originates in the more narrower doping interval inside this area. The hole pair redistribution in the pulse space constitutes the cause of the superconducting state origination by the holes repulsive screened Coulomb interaction. The coupling mechanism discussed hereby, males it possible to explain qualitatively not only the phase diagram basic peculiarities but also the key experimental facts, related to the cuprate HTSC-materials

  17. Noninvasive radio frequency for skin tightening and body contouring.

    Science.gov (United States)

    Weiss, Robert A

    2013-03-01

    The medical use of radio frequency (RF) is based on an oscillating electrical current forcing collisions between charged molecules and ions, which are then transformed into heat. RF heating occurs irrespective of chromophore or skin type and is not dependent on selective photothermolysis. RF can be delivered using monopolar, bipolar, and unipolar devices, and each method has theoretical limits of depth penetration. A variant of bipolar delivery is fractional RF delivery. In monopolar configurations, RF will penetrate deeply and return via a grounding electrode. Multiple devices are available and are detailed later in the text. RF thermal stimulation is believed to result in a microinflammatory process that promotes new collagen. By manipulating skin cooling, RF can also be used for heating and reduction of fat. Currently, the most common uses of RF-based devices are to noninvasively manage and treat skin tightening of lax skin (including sagging jowls, abdomen, thighs, and arms), as well as wrinkle reduction, cellulite improvement, and body contouring.

  18. Foot and ankle problems in Thai monks.

    Science.gov (United States)

    Vaseenon, Tanawat; Wattanarojanaporn, Thongaek; Intharasompan, Piyapong; Theeraamphon, Nipon; Auephanviriyakul, Sansanee; Phisitkul, Phinit

    2015-01-01

    Foot and ankle problems in Thai monks have not been explored. This is an unshod population, and its members have a unique lifestyle living among others in our modern era. Beginning at their ordainment, they follow strict rules about barefoot walking, the amount of daily walking, and their sitting position, practices that theoretically can increase their risk of developing foot and ankle problems. To evaluate the prevalence ofcommon foot and ankle problems in Thai monks. A cross-sectional survey was conducted in combination with foot and ankle examinations of monks living in northern Thailand Foot morphology was examined using a Harris mat footprint. Results of the interviews and the foot and ankle examinations were evaluated. Two hundred and nine monks from 28 temples were included in this study. Common foot and ankle problems found included callosity (70.8%), toe deformities (18.2%), plantar fasciitis (13.4%), metatarsalgia (3.8%), and numbness (2.9%). Callosity and toe deformities were associated with prolonged barefoot walking over extended periods since ordainment (p < 0.05). The callosity was found on the forefoot (47.3%), lateral malleolus (40.7%), and heel (12%). Arch types were considered normal in 66.4% of cases, high in 21.6%, and low in 12%. No association was found between arch type and foot and ankle problems. Callosity and toe deformity were the most common foot and ankle problems found in Thai monks, especially those with prolonged period of barefoot walking and long-term duration ofordainment. The unique pattern of walking and sitting of Thai monks may have contributed to the development of those feet and ankle problems.

  19. Proposal for the award of a contract for the supply and installation of prefabricated reinforced-concrete modules for an LHC access shaft

    CERN Document Server

    2000-01-01

    This document concerns the award of a contract for the supply and installation of 33 prefabricated reinforced-concrete modules for the PX15 access shaft. Following a market survey carried out among 39 firms in fourteen Member States, a call for tenders (IT-2714/ST/LHC) was sent on 22 May 2000 to seven firms and one consortium consisting of four firms in seven Member States. By the closing date, CERN had received five tenders from four firms and one consortium in five Member States. The Finance Committee is invited to agree to the negotiation of a contract with the consortium JOINT VENTURE CCC (CH-DE-AT), the lowest bidder after realignment, for the supply and installation of prefabricated reinforced-concrete modules for the PX15 access shaft for a total amount of 988 915 Swiss francs, not subject to revision. The consortium has indicated the following distribution by country of the contract value covered by this adjudication proposal: DE-89%; CH-6%; AT-5%.

  20. Modulating Phonation Through Alteration of Vocal Fold Medial Surface Contour

    Science.gov (United States)

    Mau, Ted; Muhlestein, Joseph; Callahan, Sean; Chan, Roger W.

    2012-01-01

    Objectives 1. To test whether alteration of the vocal fold medial surface contour can improve phonation. 2. To demonstrate that implant material properties affect vibration even when implant is deep to the vocal fold lamina propria. Study Design Induced phonation of excised human larynges. Methods Thirteen larynges were harvested within 24 hours post-mortem. Phonation threshold pressure (PTP) and flow (PTF) were measured before and after vocal fold injections using either calcium hydroxylapatite (CaHA) or hyaluronic acid (HA). Small-volume injections (median 0.0625 mL) were targeted to the infero-medial aspect of the thyroarytenoid (TA) muscle. Implant locations were assessed histologically. Results The effect of implantation on PTP was material-dependent. CaHA tended to increase PTP, whereas HA tended to decrease PTP (Wilcoxon test P = 0.00013 for onset). In contrast, the effect of implantation on PTF was similar, with both materials tending to decrease PTF (P = 0.16 for onset). Histology confirmed implant presence in the inferior half of the vocal fold vertical thickness. Conclusions Taken together, these data suggested the implants may have altered the vocal fold medial surface contour, potentially resulting in a less convergent or more rectangular glottal geometry as a means to improve phonation. An implant with a closer viscoelastic match to vocal fold cover is desirable for this purpose, as material properties can affect vibration even when the implant is not placed within the lamina propria. This result is consistent with theoretical predictions and implies greater need for surgical precision in implant placement and care in material selection. PMID:22865592

  1. Standardization of Head and Neck Contouring Using the Acanthiomeatal Line

    International Nuclear Information System (INIS)

    Desai, Snehal; Teh, Bin S.; Hinojosa, Jose; Bell, Bent C.; Paulino, Arnold C.; Butler, E. Brian

    2009-01-01

    The purpose of this study was to determine the perceived and actual chin position(s) used for radiotherapy of head-and-neck cancers in a variety of clinical settings. Dosimetrists were asked to describe the external landmarks used to set the chin position. The lateral treatment planning radiographic figures in Ang's textbook, Radiotherapy for Head and Neck Cancers: Indications and Techniques, were analyzed for chin position by drawing a horizontal line from the tip of the chin to the cervical spine. The physicians at 7 departments were asked to rate the chin positions used in their departments for head-and-neck simulations. Choices included: (1) mildly flexed, (2) neutral, (3) mildly extended, and (4) hyperextended. In addition, each center was asked to select 2 representative cases to show routine chin position. The dosimetrists fixed the chin in neutral position by placing a virtual plane defined by 3 points (the base of the nasal septum [acanthus] and the external auditory canals) perpendicular to the table top. The type of head holder was irrelevant. Eighty-two percent (31/38) of the figures in Ang's text showed positioning in the neutral position (tip of the chin intersected the cervical spine between C2-3/C3-4). Most (71.4%) of the radiotherapists thought their patients were treated in the hyperextended neck position but, in fact, 85.7% (12/14) of the simulations showed a neural neck position. Reproducible chin positioning can be obtained by using the acanthiomeatal line. Consistent use of this technique will create a uniformly positioned set of axial co-images that have consistent appearance of avoidance and lymphatic areas. This will simplify contouring on axial computed tomography (CT) images of the neck. Standardizing the chin position is an important step to developing a standardized atlas and developing an information tool for automated contouring.

  2. New method of 2-dimensional metrology using mask contouring

    Science.gov (United States)

    Matsuoka, Ryoichi; Yamagata, Yoshikazu; Sugiyama, Akiyuki; Toyoda, Yasutaka

    2008-10-01

    We have developed a new method of accurately profiling and measuring of a mask shape by utilizing a Mask CD-SEM. The method is intended to realize high accuracy, stability and reproducibility of the Mask CD-SEM adopting an edge detection algorithm as the key technology used in CD-SEM for high accuracy CD measurement. In comparison with a conventional image processing method for contour profiling, this edge detection method is possible to create the profiles with much higher accuracy which is comparable with CD-SEM for semiconductor device CD measurement. This method realizes two-dimensional metrology for refined pattern that had been difficult to measure conventionally by utilizing high precision contour profile. In this report, we will introduce the algorithm in general, the experimental results and the application in practice. As shrinkage of design rule for semiconductor device has further advanced, an aggressive OPC (Optical Proximity Correction) is indispensable in RET (Resolution Enhancement Technology). From the view point of DFM (Design for Manufacturability), a dramatic increase of data processing cost for advanced MDP (Mask Data Preparation) for instance and surge of mask making cost have become a big concern to the device manufacturers. This is to say, demands for quality is becoming strenuous because of enormous quantity of data growth with increasing of refined pattern on photo mask manufacture. In the result, massive amount of simulated error occurs on mask inspection that causes lengthening of mask production and inspection period, cost increasing, and long delivery time. In a sense, it is a trade-off between the high accuracy RET and the mask production cost, while it gives a significant impact on the semiconductor market centered around the mask business. To cope with the problem, we propose the best method of a DFM solution using two-dimensional metrology for refined pattern.

  3. Thyrotoxicosis Presenting as Unilateral Drop Foot.

    Science.gov (United States)

    Hara, Kenju; Miyata, Hajime; Motegi, Takahide; Shibano, Ken; Ishiguro, Hideaki

    2017-01-01

    Neuromuscular disorders associated with hyperthyroidism have several variations in their clinical phenotype, such as ophthalmopathy, periodic paralysis, and thyrotoxic myopathy. We herein report an unusual case of thyrotoxic myopathy presenting as unilateral drop foot. Histopathological examinations of the left tibialis anterior muscle showed marked variation in the fiber size, mild inflammatory cell infiltration, and necrotic and regenerated muscle fibers with predominantly type 1 fiber atrophy. Medical treatment with propylthiouracil resulted in complete improvement of the left drop foot. This case expands the phenotype of thyrotoxicosis and suggests that thyrotoxicosis be considered as a possible cause of unilateral drop foot.

  4. Diabetic foot syndrome as an interdisciplinary problem

    Directory of Open Access Journals (Sweden)

    Emilia Rymkiewicz

    2017-08-01

    Full Text Available Diabetes is a metabolic disease of the growing maturity. Diabetic foot syndrome is a chronic complications of diabetes. In neuropathic sensory disorders, ischemia of the lower limbs, and improper alignment metabolic control may occur in minor injuries around the foot, giving rise to a difficult healing ulcers. Even minor wounds rapidly infection by pathogenic bacteria, which significantly hinders their treatment. Health and life-saving solution in situations of persistent symptoms of infection is amputation of the lower limb. Doing so, however, does not solve the problem of diabetic and should be the final proceedings after having exhausted all possible treatments for diabetic foot syndrome.

  5. Is the foot elevation the optimal position for wound healing of a diabetic foot?

    Science.gov (United States)

    Park, D J; Han, S K; Kim, W K

    2010-03-01

    In managing diabetic foot ulcers, foot elevation has generally been recommended to reduce oedema and prevent other sequential problems. However, foot elevation may decrease tissue oxygenation of the foot more than the dependent position since the dependent position is known to increase blood flow within the arterial system. In addition, diabetic foot ulcers, which have peripheral vascular insufficiency, generally have less oedema than other wounds. Therefore, we argue that foot elevation may not be helpful for healing of vascularly compromised diabetic foot ulcers since adequate tissue oxygenation is an essential factor in diabetic wound healing. The purpose of this study was to evaluate the influence of foot height on tissue oxygenation and to determine the optimal foot position to accelerate wound healing of diabetic foot ulcers. This study included 122 cases (73 males and 47 females; two males had bilateral disease) of diabetic foot ulcer patients aged 40-93 years. Trans-cutaneous partial oxygen tension (TcpO(2)) values of diabetic feet were measured before and after foot elevation (n=21). Elevation was achieved by placing a foot over four cushions. We also measured foot TcpO(2) values before and after lowering the feet (n=122). Feet were lowered to the patient's tibial height, approximately 30-35 cm, beside a bed handrail. Due to the large number of lowering measurements, we divided them into five sub-groups according to initial TcpO(2.) Tissue oxygenation values were compared. Foot-elevation-lowered TcpO(2) values before and after elevation were 32.5+/-22.2 and 23.8+/-23.1 mmHg (pFoot-lowering-augmented TcpO(2) values before and after lowering were 44.6+/-23.8 and 58.0+/-25.9 mmHg (pfoot lowering, rather than elevation, significantly augments TcpO(2) and may stimulate healing of diabetic foot ulcers. (c) 2008 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Patient specific ankle-foot orthoses using rapid prototyping.

    Science.gov (United States)

    Mavroidis, Constantinos; Ranky, Richard G; Sivak, Mark L; Patritti, Benjamin L; DiPisa, Joseph; Caddle, Alyssa; Gilhooly, Kara; Govoni, Lauren; Sivak, Seth; Lancia, Michael; Drillio, Robert; Bonato, Paolo

    2011-01-12

    Prefabricated orthotic devices are currently designed to fit a range of patients and therefore they do not provide individualized comfort and function. Custom-fit orthoses are superior to prefabricated orthotic devices from both of the above-mentioned standpoints. However, creating a custom-fit orthosis is a laborious and time-intensive manual process performed by skilled orthotists. Besides, adjustments made to both prefabricated and custom-fit orthoses are carried out in a qualitative manner. So both comfort and function can potentially suffer considerably. A computerized technique for fabricating patient-specific orthotic devices has the potential to provide excellent comfort and allow for changes in the standard design to meet the specific needs of each patient. In this paper, 3D laser scanning is combined with rapid prototyping to create patient-specific orthoses. A novel process was engineered to utilize patient-specific surface data of the patient anatomy as a digital input, manipulate the surface data to an optimal form using Computer Aided Design (CAD) software, and then download the digital output from the CAD software to a rapid prototyping machine for fabrication. Two AFOs were rapidly prototyped to demonstrate the proposed process. Gait analysis data of a subject wearing the AFOs indicated that the rapid prototyped AFOs performed comparably to the prefabricated polypropylene design. The rapidly prototyped orthoses fabricated in this study provided good fit of the subject's anatomy compared to a prefabricated AFO while delivering comparable function (i.e. mechanical effect on the biomechanics of gait). The rapid fabrication capability is of interest because it has potential for decreasing fabrication time and cost especially when a replacement of the orthosis is required.

  7. Patient specific ankle-foot orthoses using rapid prototyping

    Directory of Open Access Journals (Sweden)

    Sivak Seth

    2011-01-01

    Full Text Available Abstract Background Prefabricated orthotic devices are currently designed to fit a range of patients and therefore they do not provide individualized comfort and function. Custom-fit orthoses are superior to prefabricated orthotic devices from both of the above-mentioned standpoints. However, creating a custom-fit orthosis is a laborious and time-intensive manual process performed by skilled orthotists. Besides, adjustments made to both prefabricated and custom-fit orthoses are carried out in a qualitative manner. So both comfort and function can potentially suffer considerably. A computerized technique for fabricating patient-specific orthotic devices has the potential to provide excellent comfort and allow for changes in the standard design to meet the specific needs of each patient. Methods In this paper, 3D laser scanning is combined with rapid prototyping to create patient-specific orthoses. A novel process was engineered to utilize patient-specific surface data of the patient anatomy as a digital input, manipulate the surface data to an optimal form using Computer Aided Design (CAD software, and then download the digital output from the CAD software to a rapid prototyping machine for fabrication. Results Two AFOs were rapidly prototyped to demonstrate the proposed process. Gait analysis data of a subject wearing the AFOs indicated that the rapid prototyped AFOs performed comparably to the prefabricated polypropylene design. Conclusions The rapidly prototyped orthoses fabricated in this study provided good fit of the subject's anatomy compared to a prefabricated AFO while delivering comparable function (i.e. mechanical effect on the biomechanics of gait. The rapid fabrication capability is of interest because it has potential for decreasing fabrication time and cost especially when a replacement of the orthosis is required.

  8. CONSIDERATIONS REGARDING THE DESIGN OF FOOTWEAR WHICH ASSURES THE HEALTH OF THE FOOT

    Directory of Open Access Journals (Sweden)

    MĂRCUŞ Liviu

    2016-05-01

    Full Text Available The high demands for cheap footwear can only be satisfied by mass fabrication. Costumed footwear would represent a regress, despite the advantages that it brings. This paper regards mainly the demands that mass footwear requires, in order to maintain the health of the foot. The desire to maintain the foot shape and functionality requires certain last forms and fabrication algorithms. We analyze certain aspects referring to: the correct design of the inner sole, insuring the flexibility of the lower part of the footwear by choosing the right type of materials and confection systems, choosing the right height of the heel, setting the adequate shape by increasing the number of different shoe sizes. In order to give a loose space to the adults’ toes, where they are not pressed, but have a complete range of motion, the orthopedists and the last specialists have set several requirements for building the contour of the inner sole. The technique of building a bond between the footwear forepart and the inferior ensemble is dependent to the purpose and partially to the fashion demands of the shoe. The sole shape is influenced by the buyers, as seen by the development of the ex-flex footwear. There must be noted that in this case, the work of the model designer coincides with the exigencies of the specialist in footwear health. With the help of certain functional considerations and of several mechanical calculations, it can be proven that a heel with a height of 3 cm does not necessarily have a negative impact on the foot health. This is why even the orthopedics consider this limit as acceptable. Higher heels must be avoided if we want to maintain a normal function and development of the foot.

  9. SU-C-BRB-05: Determining the Adequacy of Auto-Contouring Via Probabilistic Assessment of Ensuing Treatment Plan Metrics in Comparison with Manual Contours

    International Nuclear Information System (INIS)

    Nourzadeh, H; Watkins, W; Siebers, J; Ahmad, M

    2016-01-01

    Purpose: To determine if auto-contour and manual-contour—based plans differ when evaluated with respect to probabilistic coverage metrics and biological model endpoints for prostate IMRT. Methods: Manual and auto-contours were created for 149 CT image sets acquired from 16 unique prostate patients. A single physician manually contoured all images. Auto-contouring was completed utilizing Pinnacle’s Smart Probabilistic Image Contouring Engine (SPICE). For each CT, three different 78 Gy/39 fraction 7-beam IMRT plans are created; PD with drawn ROIs, PAS with auto-contoured ROIs, and PM with auto-contoured OARs with the manually drawn target. For each plan, 1000 virtual treatment simulations with different sampled systematic errors for each simulation and a different sampled random error for each fraction were performed using our in-house GPU-accelerated robustness analyzer tool which reports the statistical probability of achieving dose-volume metrics, NTCP, TCP, and the probability of achieving the optimization criteria for both auto-contoured (AS) and manually drawn (D) ROIs. Metrics are reported for all possible cross-evaluation pairs of ROI types (AS,D) and planning scenarios (PD,PAS,PM). Bhattacharyya coefficient (BC) is calculated to measure the PDF similarities for the dose-volume metric, NTCP, TCP, and objectives with respect to the manually drawn contour evaluated on base plan (D-PD). Results: We observe high BC values (BC≥0.94) for all OAR objectives. BC values of max dose objective on CTV also signify high resemblance (BC≥0.93) between the distributions. On the other hand, BC values for CTV’s D95 and Dmin objectives are small for AS-PM, AS-PD. NTCP distributions are similar across all evaluation pairs, while TCP distributions of AS-PM, AS-PD sustain variations up to %6 compared to other evaluated pairs. Conclusion: No significant probabilistic differences are observed in the metrics when auto-contoured OARs are used. The prostate auto-contour needs

  10. SU-C-BRB-05: Determining the Adequacy of Auto-Contouring Via Probabilistic Assessment of Ensuing Treatment Plan Metrics in Comparison with Manual Contours

    Energy Technology Data Exchange (ETDEWEB)

    Nourzadeh, H; Watkins, W; Siebers, J; Ahmad, M [University of Virginia Health Systems, Charlottesville, VA (United States)

    2016-06-15

    Purpose: To determine if auto-contour and manual-contour—based plans differ when evaluated with respect to probabilistic coverage metrics and biological model endpoints for prostate IMRT. Methods: Manual and auto-contours were created for 149 CT image sets acquired from 16 unique prostate patients. A single physician manually contoured all images. Auto-contouring was completed utilizing Pinnacle’s Smart Probabilistic Image Contouring Engine (SPICE). For each CT, three different 78 Gy/39 fraction 7-beam IMRT plans are created; PD with drawn ROIs, PAS with auto-contoured ROIs, and PM with auto-contoured OARs with the manually drawn target. For each plan, 1000 virtual treatment simulations with different sampled systematic errors for each simulation and a different sampled random error for each fraction were performed using our in-house GPU-accelerated robustness analyzer tool which reports the statistical probability of achieving dose-volume metrics, NTCP, TCP, and the probability of achieving the optimization criteria for both auto-contoured (AS) and manually drawn (D) ROIs. Metrics are reported for all possible cross-evaluation pairs of ROI types (AS,D) and planning scenarios (PD,PAS,PM). Bhattacharyya coefficient (BC) is calculated to measure the PDF similarities for the dose-volume metric, NTCP, TCP, and objectives with respect to the manually drawn contour evaluated on base plan (D-PD). Results: We observe high BC values (BC≥0.94) for all OAR objectives. BC values of max dose objective on CTV also signify high resemblance (BC≥0.93) between the distributions. On the other hand, BC values for CTV’s D95 and Dmin objectives are small for AS-PM, AS-PD. NTCP distributions are similar across all evaluation pairs, while TCP distributions of AS-PM, AS-PD sustain variations up to %6 compared to other evaluated pairs. Conclusion: No significant probabilistic differences are observed in the metrics when auto-contoured OARs are used. The prostate auto-contour needs

  11. Effects of background and contour luminance on the hue and brightness of the Watercolor effect.

    Science.gov (United States)

    Gerardin, Peggy; Dojat, Michel; Knoblauch, Kenneth; Devinck, Frédéric

    2018-03-01

    Conjoint measurement was used to investigate the joint influences of the luminance of the background and the inner contour on hue- and brightness filling-in for a stimulus configuration generating a water-color effect (WCE), i.e., a wiggly bi-chromatic contour enclosing a region with the lower luminance component on the exterior. Two stimuli with the background and inner contour luminances covarying independently were successively presented, and in separate experiments, the observer judged which member of the pair's interior regions contained a stronger hue or was brighter. Braided-contour control stimuli that generated little or no perceptual filling-in were also used to assess whether observers were judging the interior regions and not the contours themselves. Three nested models of the contributions of the background and inner contour to the judgments were fit to the data by maximum likelihood and evaluated by likelihood ratio tests. Both stimulus components contributed to both the hue and brightness of the interior region with increasing luminance of the inner contour generating an assimilative filling-in for the hue judgments but a contrast effect for the brightness judgments. Control analyses showed negligible effects for the order of the luminance of the background or inner contour on the judgments. An additive contribution of both components was rejected in favor of a saturated model in which the responses depended on the levels of both stimulus components. For the hue judgments, increased background luminance led to greater hue filling-in at higher luminances of the interior contour. For the brightness judgments, the higher background luminance generated less brightness filling-in at higher luminances of the interior contour. The results indicate different effects of the inner contour and background on the induction of the brightness and coloration percepts of the WCE, suggesting that they are mediated by different mechanisms. Copyright © 2018 Elsevier

  12. Retroperitoneal Sarcoma Target Volume and Organ at Risk Contour Delineation Agreement Among NRG Sarcoma Radiation Oncologists

    Energy Technology Data Exchange (ETDEWEB)

    Baldini, Elizabeth H., E-mail: ebaldini@partners.org [Department of Radiation Oncology, Dana-Farber Cancer Institute, Brigham and Women' s Hospital, Boston, Massachusetts (United States); Abrams, Ross A. [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States); Bosch, Walter [Department of Radiation Oncology, Washington University, St. Louis, Missouri (United States); Roberge, David [Department of Radiation Oncology, Centre Hospitalier de l' Universite de Montreal, Montreal, Quebec (Canada); Haas, Rick L.M. [Department of Radiotherapy, Netherlands Cancer Institute, Amsterdam (Netherlands); Catton, Charles N. [Department of Radiation Oncology, Princess Margaret Cancer Centre, Toronto, Ontario (Canada); Indelicato, Daniel J. [Department of Radiation Oncology, University of Florida Medical Center, Jacksonville, Florida (United States); Olsen, Jeffrey R. [Department of Radiation Oncology, Washington University, St. Louis, Missouri (United States); Deville, Curtiland [Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States); Chen, Yen-Lin [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Finkelstein, Steven E. [Translational Research Consortium, 21st Century Oncology, Scottsdale, Arizona (United States); DeLaney, Thomas F. [Department of Radiation Oncology, Massachusetts General Hospital, Boston, Massachusetts (United States); Wang, Dian [Department of Radiation Oncology, Rush University Medical Center, Chicago, Illinois (United States)

    2015-08-01

    Purpose: The purpose of this study was to evaluate the variability in target volume and organ at risk (OAR) contour delineation for retroperitoneal sarcoma (RPS) among 12 sarcoma radiation oncologists. Methods and Materials: Radiation planning computed tomography (CT) scans for 2 cases of RPS were distributed among 12 sarcoma radiation oncologists with instructions for contouring gross tumor volume (GTV), clinical target volume (CTV), high-risk CTV (HR CTV: area judged to be at high risk of resulting in positive margins after resection), and OARs: bowel bag, small bowel, colon, stomach, and duodenum. Analysis of contour agreement was performed using the simultaneous truth and performance level estimation (STAPLE) algorithm and kappa statistics. Results: Ten radiation oncologists contoured both RPS cases, 1 contoured only RPS1, and 1 contoured only RPS2 such that each case was contoured by 11 radiation oncologists. The first case (RPS 1) was a patient with a de-differentiated (DD) liposarcoma (LPS) with a predominant well-differentiated (WD) component, and the second case (RPS 2) was a patient with DD LPS made up almost entirely of a DD component. Contouring agreement for GTV and CTV contours was high. However, the agreement for HR CTVs was only moderate. For OARs, agreement for stomach, bowel bag, small bowel, and colon was high, but agreement for duodenum (distorted by tumor in one of these cases) was fair to moderate. Conclusions: For preoperative treatment of RPS, sarcoma radiation oncologists contoured GTV, CTV, and most OARs with a high level of agreement. HR CTV contours were more variable. Further clarification of this volume with the help of sarcoma surgical oncologists is necessary to reach consensus. More attention to delineation of the duodenum is also needed.

  13. Can Images Obtained With High Field Strength Magnetic Resonance Imaging Reduce Contouring Variability of the Prostate?

    International Nuclear Information System (INIS)

    Usmani, Nawaid; Sloboda, Ron; Kamal, Wafa; Ghosh, Sunita; Pervez, Nadeem; Pedersen, John; Yee, Don; Danielson, Brita; Murtha, Albert; Amanie, John; Monajemi, Tara

    2011-01-01

    Purpose: The objective of this study is to determine whether there is less contouring variability of the prostate using higher-strength magnetic resonance images (MRI) compared with standard MRI and computed tomography (CT). Methods and Materials: Forty patients treated with prostate brachytherapy were accrued to a prospective study that included the acquisition of 1.5-T MR and CT images at specified time points. A subset of 10 patients had additional 3.0-T MR images acquired at the same time as their 1.5-T MR scans. Images from each of these patients were contoured by 5 radiation oncologists, with a random subset of patients repeated to quantify intraobserver contouring variability. To minimize bias in contouring the prostate, the image sets were placed in folders in a random order with all identifiers removed from the images. Results: Although there was less interobserver contouring variability in the overall prostate volumes in 1.5-T MRI compared with 3.0-T MRI (p < 0.01), there was no significant differences in contouring variability in the different regions of the prostate between 1.5-T MRI and 3.0-T MRI. MRI demonstrated significantly less interobserver contouring variability in both 1.5-T and 3.0-T compared with CT in overall prostate volumes (p < 0.01, p = 0.01), with the greatest benefits being appreciated in the base of the prostate. Overall, there was less intraobserver contouring variability than interobserver contouring variability for all of the measurements analyzed. Conclusions: Use of 3.0-T MRI does not demonstrate a significant improvement in contouring variability compared with 1.5-T MRI, although both magnetic strengths demonstrated less contouring variability compared with CT.

  14. Retroperitoneal Sarcoma Target Volume and Organ at Risk Contour Delineation Agreement Among NRG Sarcoma Radiation Oncologists

    International Nuclear Information System (INIS)

    Baldini, Elizabeth H.; Abrams, Ross A.; Bosch, Walter; Roberge, David; Haas, Rick L.M.; Catton, Charles N.; Indelicato, Daniel J.; Olsen, Jeffrey R.; Deville, Curtiland; Chen, Yen-Lin; Finkelstein, Steven E.; DeLaney, Thomas F.; Wang, Dian

    2015-01-01

    Purpose: The purpose of this study was to evaluate the variability in target volume and organ at risk (OAR) contour delineation for retroperitoneal sarcoma (RPS) among 12 sarcoma radiation oncologists. Methods and Materials: Radiation planning computed tomography (CT) scans for 2 cases of RPS were distributed among 12 sarcoma radiation oncologists with instructions for contouring gross tumor volume (GTV), clinical target volume (CTV), high-risk CTV (HR CTV: area judged to be at high risk of resulting in positive margins after resection), and OARs: bowel bag, small bowel, colon, stomach, and duodenum. Analysis of contour agreement was performed using the simultaneous truth and performance level estimation (STAPLE) algorithm and kappa statistics. Results: Ten radiation oncologists contoured both RPS cases, 1 contoured only RPS1, and 1 contoured only RPS2 such that each case was contoured by 11 radiation oncologists. The first case (RPS 1) was a patient with a de-differentiated (DD) liposarcoma (LPS) with a predominant well-differentiated (WD) component, and the second case (RPS 2) was a patient with DD LPS made up almost entirely of a DD component. Contouring agreement for GTV and CTV contours was high. However, the agreement for HR CTVs was only moderate. For OARs, agreement for stomach, bowel bag, small bowel, and colon was high, but agreement for duodenum (distorted by tumor in one of these cases) was fair to moderate. Conclusions: For preoperative treatment of RPS, sarcoma radiation oncologists contoured GTV, CTV, and most OARs with a high level of agreement. HR CTV contours were more variable. Further clarification of this volume with the help of sarcoma surgical oncologists is necessary to reach consensus. More attention to delineation of the duodenum is also needed

  15. Residual stress measurement of EB-welded plates with contour method. Part 2: FEM analysis of contour profiles

    International Nuclear Information System (INIS)

    Romppanen, A.-J.; Immonen, E.

    2013-12-01

    The residual stresses formed as a result of Electronic Beam welding (EB-welding) in copper are investigated by Posiva. In the present study, residual stresses of EB-welded copper plates were studied with contour method. In the method eleven copper plates (X436 - X440 and X453 - X458) were cut in half with wire electric discharge machining (EDM) after which the deformation due to stress relaxation was measured with coordinate measurement system. The measured data was then used as boundary displacement data for the FEM analyses, in which the corresponding residual stresses were calculated. Before giving the corresponding displacement boundary conditions to the FE models, the deformation data was processed and smoothed appropriately. The residual stress levels of the copper plates were found to be around 40 - 55 MPa at maximum. This corresponds to other reported residual stress measurements and current state of knowledge with this material in Posiva. (orig.)

  16. Gender differences of foot characteristics in older Japanese adults using a 3D foot scanner.

    Science.gov (United States)

    Saghazadeh, Mahshid; Kitano, Naruki; Okura, Tomohiro

    2015-01-01

    Knowledge of gender differences in foot shape assists shoe manufactures with designing appropriate shoes for men and women. Although gender differences in foot shapes are relatively known among young men and women, less is known about how the older men and women's feet differ in shape. A recent development in foot shape assessment is the use of 3D foot scanners. To our knowledge this technology has yet to be used to examine gender differences in foot shape of Japanese older adults. This cross-sectional study included 151 older men (74.5 ± 5.6 years) and 140 older women (73.9 ± 5.1 years) recruited in Kasama City, Japan. Foot variables were measured in sitting and standing positions using Dream GP Incorporated's 3D foot scanner, Footstep PRO (Osaka, Japan). Scores were analyzed as both raw and normalized to truncated foot length using independent samples t-test and analysis of covariance, respectively. In men, the measurement values for navicular height, first and fifth toe and instep heights, ball and heel width, ball girth, arch height index (just standing), arch rigidity index and instep girth were significantly greater than the women's, whereas the first toe angle, in both sitting and standing positions was significantly smaller. However, after normalizing, the differences in ball width, heel width, height of first and fifth toes in both sitting and standing and ball girth in sitting position were nonsignificant. According to Cohen's d, among all the foot variables, the following had large effect sizes in both sitting and standing positions: truncated foot length, instep, navicular height, foot length, ball girth, ball width, heel width and instep girth. This study provides evidence of anthropometric foot variations between older men and women. These differences need to be considered when manufacturing shoes for older adults.

  17. Foot Complications in a Representative Australian Inpatient Population

    Directory of Open Access Journals (Sweden)

    Peter A. Lazzarini

    2017-01-01

    Full Text Available We investigated the prevalence and factors independently associated with foot complications in a representative inpatient population (adults admitted for any reason with and without diabetes. We analysed data from the Foot disease in inpatients study, a sample of 733 representative inpatients. Previous amputation, previous foot ulceration, peripheral arterial disease (PAD, peripheral neuropathy (PN, and foot deformity were the foot complications assessed. Sociodemographic, medical, and foot treatment history were collected. Overall, 46.0% had a foot complication with 23.9% having multiple; those with diabetes had higher prevalence of foot complications than those without diabetes (p<0.01. Previous amputation (4.1% was independently associated with previous foot ulceration, foot deformity, cerebrovascular accident, and past surgeon treatment (p<0.01. Previous foot ulceration (9.8% was associated with PN, PAD, past podiatry, and past nurse treatment (p<0.02. PAD (21.0% was associated with older age, males, indigenous people, cancer, PN, and past surgeon treatment (p<0.02. PN (22.0% was associated with older age, diabetes, mobility impairment, and PAD (p<0.05. Foot deformity (22.4% was associated with older age, mobility impairment, past podiatry treatment, and PN (p<0.01. Nearly half of all inpatients had a foot complication. Those with foot complications were older, male, indigenous, had diabetes, cerebrovascular accident, mobility impairment, and other foot complications or past foot treatment.

  18. Effect of forward/backward standing posture on foot shape

    NARCIS (Netherlands)

    Daanen, H.A.M.; Tan, T.K.; Punte, P.A.J.

    2000-01-01

    Foot length and breadth are generally used to determine the correct shoe size. An important question is whether foot length and foot breadth are dependent upon body posture. Therefore, the effect of leaning forward/backward on foot length and breadth is investigated in this study. Seven subjects

  19. Isolation of a substance activating foot formation in hydra

    DEFF Research Database (Denmark)

    Grimmelikhuijzen, C J; Schaller, H C

    1977-01-01

    -forming potential of the tissue (2) It does not accelerate head regeneration, nor do the head factors of hydra discovered by Schaller (1973) and Berking (1977) accelerate foot regeneration. We propose that the foot-activating substance is a morphogen responsible for foot formation in hydra. The foot activator can...

  20. Clinical and functional correlates of foot pain in diabetic patients.

    NARCIS (Netherlands)

    Rijken, P.M.; Dekker, J.; Rauwerda, J.A.; Dekker, E.; Lankhorst, G.J.; Bakker, K.; Dooren, J.

    1998-01-01

    Purpose: patients with diabetes mellitus frequently suffer from foot pain. This pain seems to be a neglected area in studies on the diabetic foot. The purpose of this study was to identify clinical variables associated with foot pain in diabetic patients. In addition, the relationships between foot

  1. Increased plantar foot pressure in persons affected by leprosy

    NARCIS (Netherlands)

    Slim, Frederik J.; van Schie, Carine H.; Keukenkamp, Renske; Faber, William R.; Nollet, Frans

    2012-01-01

    Although foot pressure has been reported to be increased in people affected by leprosy, studies on foot pressure and its determinants are limited. Therefore, the aim was to assess barefoot plantar foot pressure and to identify clinical determinants of increased plantar foot pressure in leprosy

  2. Hand, Foot, and Mouth Disease (HFMD)

    Science.gov (United States)

    ... feature story, podcast, and other CDC resources about personal hygiene... Prevention People infected with hand, foot, and mouth ... these countries can protect themselves by practicing good personal hygiene. Learn more . To learn more about outbreaks occurring ...

  3. Radiographic examination of the equine foot

    International Nuclear Information System (INIS)

    Park, R.D.

    1989-01-01

    A complete radiographic examination of the equine foot consists of properly exposed, processed, and positioned radiographs. For radiographic interpretation, in addition to knowing radiographic signs of disease, a knowledge of normal radiographic anatomy and possible insignificant anatomic variations is necessary

  4. Formal Design Review Foot Clamp Modification

    International Nuclear Information System (INIS)

    OTEN, T.C.

    2000-01-01

    This report documents the Design Review performed for the foot clamp modification. The report documents the acceptability of the design, identifies the documents that were reviewed, the scope of the review and the members of the review team

  5. Glossary of Foot and Ankle Terms

    Science.gov (United States)

    ... long bones of the fingers or toes. Plantar fascia - Plantar fascia is a thin layer of tough tissue supporting ... the foot. Plantar fasciitis - An inflammation of the plantar fascia. Symptoms are usually pain at the bottom of ...

  6. The chicken foot digital replant training model.

    Science.gov (United States)

    Athanassopoulos, Thanassi; Loh, Charles Yuen Yung

    2015-01-01

    A simple, readily available digital replantation model in the chicken foot is described. This high fidelity model will hopefully allow trainees in hand surgery to gain further experience in replant surgery prior to clinical application.

  7. On-the-Job Foot Health

    Science.gov (United States)

    ... improves your efficiency and keeps you on the job. Your podiatric physician and surgeon is a specialist ... 20814 FP-65M-4/96 2014 ON-THE-JOB FOOT HEALTH YOUR PODIATRIC PHYSICIAN TALKS ABOUT ON- ...

  8. 130 DIABETIC FOOT ULCERS: CURRENT TRENDS IN ...

    African Journals Online (AJOL)

    drclement

    *Department of Orthopaedics and Trauma, University of Benin Teaching Hospital, ... well as patient education will markedly .... broad spectrum antibiotic therapy only .... Discuss any foot powders with a healthcare professional prior to use. 2.

  9. Angiography in the region of the foot

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E.

    1984-06-01

    It is reported on technique, incidence and findings of angiography of the foot which provided magnifying angiography and non-ionic contrast media are used, is especially qualified for the differentiation of diabetic and non-diabetic angiopathies as well as for the identification of peripherical embolizations and digital arterial occlusions at thrombocytosis or polycythemia. The arteries of the foot represent the peripherical outflow at peripherical reconstructive performances at the lower leg and have to be studied prior to such reconstructive surgical interventions. The different localization of arterial obliterations and changes of the walls in diabetics of stage I-IV according to Fontaine shows the particularly large number of vascular-pathological findings in arteries of the lower leg and foot in diabetics with arterial occlusive diseases of stage III and IV. Therefore, the unfavourable prognoses of arterial occlusive diseases in diabetics have also to be made for peripherical arterial obliterations of the foot and lower leg.

  10. Angiography in the region of the foot

    International Nuclear Information System (INIS)

    Zeitler, E.

    1984-01-01

    It is reported on technique, incidence and findings of angiography of the foot which provided magnifying angiography and non-ionic contrast media are used, is especially qualified for the differentiation of diabetic and non-diabetic angiopathies as well as for the identification of peripherical embolizations and digital arterial occlusions at thrombocytosis or polycythemia. The arteries of the foot represent the peripherical outflow at peripherical reconstructive performances at the lower leg and have to be studied prior to such reconstructive surgical interventions. The different localization of arterial obliterations and changes of the walls in diabetics of stage I-IV according to Fontaine shows the particularly large number of vascular-pathological findings in arteries of the lower leg and foot in diabetics with arterial occlusive diseases of stage III and IV. Therefore, the unfavourable prognoses of arterial occlusive diseases in diabetics have also to be made for peripherical arterial obliterations of the foot and lower leg. (orig.) [de

  11. Natural gaits of the non-pathological flat foot and high-arched foot

    OpenAIRE

    Fan, Yifang; Fan, Yubo; Li, Zhiyu; Lv, Changsheng; Luo, Donglin

    2010-01-01

    There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static footprints from subjects adopting a half-weight-bearing stance. Based upon their footprints, the subjects were divided into two groups: the flat-footed and the high-arched. The plantar pressure measurement system was used to measure and record the subjects' successive natural gaits. Two indic...

  12. The Glasgow-Maastricht foot model, evaluation of a 26 segment kinematic model of the foot.

    Science.gov (United States)

    Oosterwaal, Michiel; Carbes, Sylvain; Telfer, Scott; Woodburn, James; Tørholm, Søren; Al-Munajjed, Amir A; van Rhijn, Lodewijk; Meijer, Kenneth

    2016-01-01

    Accurately measuring of intrinsic foot kinematics using skin mounted markers is difficult, limited in part by the physical dimensions of the foot. Existing kinematic foot models solve this problem by combining multiple bones into idealized rigid segments. This study presents a novel foot model that allows the motion of the 26 bones to be individually estimated via a combination of partial joint constraints and coupling the motion of separate joints using kinematic rhythms. Segmented CT data from one healthy subject was used to create a template Glasgow-Maastricht foot model (GM-model). Following this, the template was scaled to produce subject-specific models for five additional healthy participants using a surface scan of the foot and ankle. Forty-three skin mounted markers, mainly positioned around the foot and ankle, were used to capture the stance phase of the right foot of the six healthy participants during walking. The GM-model was then applied to calculate the intrinsic foot kinematics. Distinct motion patterns where found for all joints. The variability in outcome depended on the location of the joint, with reasonable results for sagittal plane motions and poor results for transverse plane motions. The results of the GM-model were comparable with existing literature, including bone pin studies, with respect to the range of motion, motion pattern and timing of the motion in the studied joints. This novel model is the most complete kinematic model to date. Further evaluation of the model is warranted.

  13. [Foot growth and foot types in children and adolescents: a narrative review].

    Science.gov (United States)

    Xu, Miaomiao; Wang, Lin

    2017-08-01

    Foot shape and size are important for footwear design and production. Information about important foot characteristics helps not only to improve shoe comfort but to maintain the proper physiological development of the feet. What's more, plenty of studies have suggested that the shape of the shoe must closely resemble the shape of the foot to create a properly fitted shoe. This means that the differences between various populations should be considered and that footwear should be designed according to the measurements of users. Childhood and adolescent are important periods of human growth. During these periods, foot shape changes with human growth and can be influenced by extrinsic factors. Therefore, the foot shape characteristics of children and adolescents should be investigated. The results from these investigations can contribute to developing appropriate shoe for children and adolescents, improving perceived comfort of children shoes and preventing pedopathy among children and adolescents. This review aims to discuss measuring methods of foot shape, types of foot shape, and factors influencing foot shape. The results of the review can provide recommendations for investigating growth development of foot shape and useful information for consumers and shoe manufacturers.

  14. Foot Marching, Load Carriage, and Injury Risk

    Science.gov (United States)

    2016-05-01

    Foot blisters: Though not a musculoskeletal injury , past studies and reviews have described foot blisters as one of the most common marching... injuries were the highest among all activities in these studies, ranging from 36 to 69 limited duty days per injury .23, 24 The top three most common ...Knapik, and J.J. 1994. Exercise, training and injuries . Sports Med 18(3): 202-1. 35. APHC (Prov) Blister Prevention Factsheet. 2015. Available at

  15. Postoperative infection in the foot and ankle.

    LENUS (Irish Health Repository)

    Chan, Victoria O

    2012-07-01

    Our discussion highlights the commonly performed surgical procedures in the foot and ankle and reviews the various imaging modalities available for the detection of infection with graphic examples to better enable radiologists to approach the radiological evaluation of postoperative infection in the foot and ankle. Discrimination between infectious and noninfectious inflammation remains a diagnostic challenge usually needing a combination of clinical assessment, laboratory investigations, and imaging studies to increase diagnostic accuracy.

  16. CLINICOMICROBIOLOGICAL STUDY OF DIABETIC FOOT ULCERS

    Directory of Open Access Journals (Sweden)

    Nirmal Kumar Palaniappan

    2017-11-01

    Full Text Available BACKGROUND Type 2 diabetes mellitus is a chronic disease caused by a combination of lifestyle and genetic factors affecting all organs in the body. Foot ulcers are one of the common and serious long-term complications of diabetes leads to recurrent and chronic infections, which results in limb loss when treatment is delayed. The aim of this study is to find out the clinical outcome and microbiological profile in patients admitted with diabetic foot ulcers. MATERIALS AND METHODS The study conducted between November 2008 to November 2009 over 50 patients with history of foot ulceration and diabetes. 50 patients were admitted with diabetic foot ulcer over a period of one year between November 2008-2009. They were studied after getting written consent. A predesigned pro forma was used to get the parameters comprising age, gender, duration, type of diabetes mellitus, presence of neuropathy, nephropathy (serum creatinine, urine albumin, retinopathy (screening funduscopy by ophthalmologist. RESULTS Among 50 patients admitted and treated for diabetic foot ulcers with mean stay of 18 days, 29 (58% had complete healing on conservative management, 18 (36% underwent minor amputation (toes, 3 (6% had major amputation (below knee/above knee. No mortality among the study groups encountered. Gram-negative aerobes E. coli (36%, Pseudomonas (52%, Klebsiella (28%, Proteus vulgaris (20% and Acinetobacter (16% were most frequently isolated followed by gram-positive aerobes MRSA (14%, Enterococcus (6%, Strep pyogenes (4% and no anaerobic growth. CONCLUSION Diabetic foot infections are frequently polymicrobial and predominantly gram-negative aerobic bacteria at presentation. Multidrug resistance pseudomonas aeruginosa and MRSA in diabetic foot ulcer is at its emergence and life threatening. Initial aggressive multimodal approach with surgical intervention, culture specific and sensitive targeted combined broad-spectrum antibiotics decreases the morbidity and mortality

  17. 47 CFR 73.6010 - Class A TV station protected contour.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Class A TV station protected contour. 73.6010... RADIO BROADCAST SERVICES Class A Television Broadcast Stations § 73.6010 Class A TV station protected contour. (a) A Class A TV station will be protected from interference within the following predicted...

  18. I/O-Efficient Algorithms for Computing Contour Lines on a Terrain

    DEFF Research Database (Denmark)

    Agarwal, Pankaj Kumar; Arge, Lars; Sadri, Bardia

    2008-01-01

    A terrain M is the graph of a bivariate function. We assume that M is represented as a triangulated surface with N vertices. A contour (or isoline) of M is a connected component of a level set of M. Generically, each contour is a closed polygonal curve; at "critical" levels these curves may touch...

  19. Free-convective flow of fluid in a thin porous contour and geothermal anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Magomedbekov Kh.G.; Ramazanov, M.M.; Vagabov, M.V.

    1996-01-24

    The problem of free convection in a thin porous contour, placed in uniform impermeable massif is considered. The approximate analitical solution of conjugate problem is obtained. The critical Rayleigh number is determined, by exceeding of which the steady fluid circulation in an annulus is established. The computations of abnormal heat flow near surface are carried out, stipulated by thermoconvection in a contour.

  20. Tonal Language Background and Detecting Pitch Contour in Spoken and Musical Items

    Science.gov (United States)

    Stevens, Catherine J.; Keller, Peter E.; Tyler, Michael D.

    2013-01-01

    An experiment investigated the effect of tonal language background on discrimination of pitch contour in short spoken and musical items. It was hypothesized that extensive exposure to a tonal language attunes perception of pitch contour. Accuracy and reaction times of adult participants from tonal (Thai) and non-tonal (Australian English) language…

  1. Contour Propagation Using Feature-Based Deformable Registration for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yuhan Yang

    2013-01-01

    Full Text Available Accurate target delineation of CT image is a critical step in radiotherapy treatment planning. This paper describes a novel strategy for automatic contour propagation, based on deformable registration, for CT images of lung cancer. The proposed strategy starts with a manual-delineated contour in one slice of a 3D CT image. By means of feature-based deformable registration, the initial contour in other slices of the image can be propagated automatically, and then refined by active contour approach. Three algorithms are employed in the strategy: the Speeded-Up Robust Features (SURF, Thin-Plate Spline (TPS, and an adapted active contour (Snake, used to refine and modify the initial contours. Five pulmonary cancer cases with about 400 slices and 1000 contours have been used to verify the proposed strategy. Experiments demonstrate that the proposed strategy can improve the segmentation performance in the pulmonary CT images. Jaccard similarity (JS mean is about 0.88 and the maximum of Hausdorff distance (HD is about 90%. In addition, delineation time has been considerably reduced. The proposed feature-based deformable registration method in the automatic contour propagation improves the delineation efficiency significantly.

  2. Iterative Method of Regularization with Application of Advanced Technique for Detection of Contours

    International Nuclear Information System (INIS)

    Niedziela, T.; Stankiewicz, A.

    2000-01-01

    This paper proposes a novel iterative method of regularization with application of an advanced technique for detection of contours. To eliminate noises, the properties of convolution of functions are utilized. The method can be accomplished in a simple neural cellular network, which creates the possibility of extraction of contours by automatic image recognition equipment. (author)

  3. What Property of the Contour of a Deforming Region Biases Percepts toward Liquid?

    Directory of Open Access Journals (Sweden)

    Takahiro Kawabe

    2017-06-01

    Full Text Available Human observers can perceive the existence of a transparent surface from dynamic image deformation. They can also easily discriminate a transparent solid material such as plastic and glass from a transparent fluid one such as water and shampoo just by viewing them. However, the image information required for material discrimination of this sort is still unclear. A liquid changes its contour shape non-rigidly. We therefore examined whether additional properties of the contour of a deformation-defined region, which indicated contour non-rigidity, biased percepts of the region toward liquid materials. Our stimuli had a translating circular region wherein a natural texture image was deformed at the spatiotemporal deformation frequency that was optimal for the perception of a transparent layer. In Experiment 1, we dynamically deformed the contour of the circular region and found that large deformation of the contour biased the percept toward liquid. In Experiment 2, we manipulated the blurriness of the contour and observed that a strongly blurred contour biased percepts toward liquid. Taken together, the results suggest that a deforming region lacking a discrete contour biases percepts toward liquid.

  4. An Investigation of Visual Contour Integration Ability in Relation to Writing Performance in Primary School Students

    Science.gov (United States)

    Li-Tsang, Cecilia W. P.; Wong, Agnes S. K.; Chan, Jackson Y.; Lee, Amos Y. T.; Lam, Miko C. Y.; Wong, C. W.; Lu, Zhonglin

    2012-01-01

    A previous study found a visual deficit in contour integration in English readers with dyslexia (Simmers & Bex, 2001). Visual contour integration may play an even more significant role in Chinese handwriting particularly due to its logographic presentation (Lam, Au, Leung, & Li-Tsang, 2011). The current study examined the relationship…

  5. 30 CFR 785.16 - Permits incorporating variances from approximate original contour restoration requirements for...

    Science.gov (United States)

    2010-07-01

    ... approximate original contour restoration requirements for steep slope mining. 785.16 Section 785.16 Mineral Resources OFFICE OF SURFACE MINING RECLAMATION AND ENFORCEMENT, DEPARTMENT OF THE INTERIOR SURFACE COAL... approximate original contour restoration requirements for steep slope mining. (a) The regulatory authority may...

  6. Fourier Descriptor Analysis and Unification of Voice Range Profile Contours: Method and Applications

    Science.gov (United States)

    Pabon, Peter; Ternstrom, Sten; Lamarche, Anick

    2011-01-01

    Purpose: To describe a method for unified description, statistical modeling, and comparison of voice range profile (VRP) contours, even from diverse sources. Method: A morphologic modeling technique, which is based on Fourier descriptors (FDs), is applied to the VRP contour. The technique, which essentially involves resampling of the curve of the…

  7. ANALYTICAL ENGINEERING OF A TELECONTROLLED PILOTLESS AIRCRAFT CONTOUR IN ACCORDANCE WITH GENERALIZED WORK CRITERION

    Directory of Open Access Journals (Sweden)

    A. M. Eromin

    2015-01-01

    Full Text Available The article considers the non­terminal problem for neutral contour of a telecontrolled pilotless aircraft. Optimal control synthesis is provided on the basis of minimization of generalized work functional. The analysis of optimal telecontrolled pilotless aircraft contour is carried out.

  8. Differential contribution of early visual areas to the perceptual process of contour processing.

    Science.gov (United States)

    Schira, Mark M; Fahle, Manfred; Donner, Tobias H; Kraft, Antje; Brandt, Stephan A

    2004-04-01

    We investigated contour processing and figure-ground detection within human retinotopic areas using event-related functional magnetic resonance imaging (fMRI) in 6 healthy and naïve subjects. A figure (6 degrees side length) was created by a 2nd-order texture contour. An independent and demanding foveal letter-discrimination task prevented subjects from noticing this more peripheral contour stimulus. The contour subdivided our stimulus into a figure and a ground. Using localizers and retinotopic mapping stimuli we were able to subdivide each early visual area into 3 eccentricity regions corresponding to 1) the central figure, 2) the area along the contour, and 3) the background. In these subregions we investigated the hemodynamic responses to our stimuli and compared responses with or without the contour defining the figure. No contour-related blood oxygenation level-dependent modulation in early visual areas V1, V3, VP, and MT+ was found. Significant signal modulation in the contour subregions of V2v, V2d, V3a, and LO occurred. This activation pattern was different from comparable studies, which might be attributable to the letter-discrimination task reducing confounding attentional modulation. In V3a, but not in any other retinotopic area, signal modulation corresponding to the central figure could be detected. Such contextual modulation will be discussed in light of the recurrent processing hypothesis and the role of visual awareness.

  9. Principle and realization of segmenting contour series algorithm in reverse engineering based on X-ray computerized tomography

    International Nuclear Information System (INIS)

    Wang Yanfang; Liu Li; Yan Yonglian; Shan Baoci; Tang Xiaowei

    2007-01-01

    A new algorithm of segmenting contour series of images is presented, which can achieve three dimension reconstruction with parametric recognition in Reverse Engineering based on X-ray CT. First, in order to get the nested relationship between contours, a method of a certain angle ray is used. Second, for realizing the contour location in one slice, another approach is presented to generate the contour tree by scanning the relevant vector only once. Last, a judge algorithm is put forward to accomplish the contour match between slices by adopting the qualitative and quantitative properties. The example shows that this algorithm can segment contour series of CT parts rapidly and precisely. (authors)

  10. Robust iterative learning contouring controller with disturbance observer for machine tool feed drives.

    Science.gov (United States)

    Simba, Kenneth Renny; Bui, Ba Dinh; Msukwa, Mathew Renny; Uchiyama, Naoki

    2018-04-01

    In feed drive systems, particularly machine tools, a contour error is more significant than the individual axial tracking errors from the view point of enhancing precision in manufacturing and production systems. The contour error must be within the permissible tolerance of given products. In machining complex or sharp-corner products, large contour errors occur mainly owing to discontinuous trajectories and the existence of nonlinear uncertainties. Therefore, it is indispensable to design robust controllers that can enhance the tracking ability of feed drive systems. In this study, an iterative learning contouring controller consisting of a classical Proportional-Derivative (PD) controller and disturbance observer is proposed. The proposed controller was evaluated experimentally by using a typical sharp-corner trajectory, and its performance was compared with that of conventional controllers. The results revealed that the maximum contour error can be reduced by about 37% on average. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.

  11. Radiodiagnosis of gastric diseases on the basis of thin contour findings

    International Nuclear Information System (INIS)

    Zubarev, A.V.; Zavodnov, V.Ya.; Sklyanskaya, O.A.

    1988-01-01

    The authors have analyzed the role of the thin contour in radiodiagnisis of various diseases of the gastric mucosa. Altogether 140 patients with various gastric diseases were investigated. Using X-ray examination of the stomach based on the common 2-phase method, thin contour images were obtained in 80 % of the cases. The results of the investigation have revealed direct correlation between the type of the thin contour and a morphological picture of the gastric mucosa in chronic gastritis. Early stomach cancer was characterized by the local absence or rearrangement of a usual pattern of the thin contour on stomach radiograms. It was difficult to defect single erosions or polyps with a diameter under 5 mm against a background of the gastric mucosa thin contour. Good visualization of stomach areolae, particularly those of a rough nodular type in the proximal part of the stomach was suggestive of an ulcerative lesion

  12. An automated approach for segmentation of intravascular ultrasound images based on parametric active contour models

    International Nuclear Information System (INIS)

    Vard, Alireza; Jamshidi, Kamal; Movahhedinia, Naser

    2012-01-01

    This paper presents a fully automated approach to detect the intima and media-adventitia borders in intravascular ultrasound images based on parametric active contour models. To detect the intima border, we compute a new image feature applying a combination of short-term autocorrelations calculated for the contour pixels. These feature values are employed to define an energy function of the active contour called normalized cumulative short-term autocorrelation. Exploiting this energy function, the intima border is separated accurately from the blood region contaminated by high speckle noise. To extract media-adventitia boundary, we define a new form of energy function based on edge, texture and spring forces for the active contour. Utilizing this active contour, the media-adventitia border is identified correctly even in presence of branch openings and calcifications. Experimental results indicate accuracy of the proposed methods. In addition, statistical analysis demonstrates high conformity between manual tracing and the results obtained by the proposed approaches.

  13. Contributions of foot muscles and plantar fascia morphology to foot posture.

    Science.gov (United States)

    Angin, Salih; Mickle, Karen J; Nester, Christopher J

    2018-03-01

    The plantar foot muscles and plantar fascia differ between different foot postures. However, how each individual plantar structure contribute to foot posture has not been explored. The purpose of this study was to investigate the associations between static foot posture and morphology of plantar foot muscles and plantar fascia and thus the contributions of these structures to static foot posture. A total of 111 participants were recruited, 43 were classified as having pes planus and 68 as having normal foot posture using Foot Posture Index assessment tool. Images from the flexor digitorum longus (FDL), flexor hallucis longus (FHL), peroneus longus and brevis (PER), flexor hallucis brevis (FHB), flexor digitorum brevis (FDB) and abductor hallucis (AbH) muscles, and the calcaneal (PF1), middle (PF2) and metatarsal (PF3) regions of the plantar fascia were obtained using a Venue 40 ultrasound system with a 5-13 MHz transducer. In order of decreasing contribution, PF3 > FHB > FHL > PER > FDB were all associated with FPI and able to explain 69% of the change in FPI scores. PF3 was the highest contributor explaining 52% of increases in FPI score. Decreased thickness was associated with increased FPI score. Smaller cross sectional area (CSA) in FHB and PER muscles explained 20% and 8% of increase in FPI score. Larger CSA of FDB and FHL muscles explained 4% and 14% increase in FPI score respectively. The medial plantar structures and the plantar fascia appear to be the major contributors to static foot posture. Elucidating the individual contribution of multiple muscles of the foot could provide insight about their role in the foot posture. Copyright © 2018. Published by Elsevier B.V.

  14. Taiwanese adult foot shape classification using 3D scanning data.

    Science.gov (United States)

    Lee, Yu-Chi; Wang, Mao-Jiun

    2015-01-01

    This study classifies the foot shapes of Taiwanese using 3D foot scanning data from 2000 males and 1000 females. Nine foot dimensions relative to foot length and absolute measures in the common foot length categories were applied to compare the gender differences. Using foot breadth in % foot length (% FL), ball of foot length in % FL and arch height in % FL as feature parameters, three foot shape types for males and females can be classified. Significant gender differences were found in seven of the nine foot dimensions. Females had greater ball of foot length than males (0.2% FL). When comparing feet of the same foot length, males had greater breadth, girth and height dimensions than females, except for toe height. In addition, ethnic differences in foot shape were also observed. The findings can provide very useful information for building gender-specific shoe lasts and designing footwear insoles. 3D foot scanning data of 2000 males and 1000 females were classified into three different footshapes for males and females, respectively. Gender and ethnic differences on foot shape were also compared. The finding scan provide very useful information for gender-specific shoe last design and footwear production.

  15. [Factors influencing the quality of life of elderly living in a pre-fabricated housing complex in the Sichuan earthquake area].

    Science.gov (United States)

    Guo, Hong-Xia; Chen, Hong; Wong, Teresa Bik-Kwan Tsien; Chen, Qian; Au, May-Lan; Li, Yun

    2012-02-01

    The 2008 Sichuan Earthquake caused great damage to the environment and property. In the aftermath, many citizens were relocated to live in newly constructed prefabricated (prefab) communities. This paper explored the current quality of life (QOL) of elderly residents living in prefabricated communities in areas damaged by the Sichuan earthquake and identified factors of influence on QOL values. The ultimate objective was to provide evidence-based guidance for heath improvement measures. The authors used the short form WHOQOL-BREF to assess the quality of life of 191 elderly residents of prefabricated communities in the Sichuan Province 2008 earthquake zone. A Student's t-test, variance analysis, and stepwise multivariate regression methods were used to test the impact of various factors on QOL. Results indicate the self-assessed QOL of participants as good, although scores in the physical (average 56.2) and psychological (average 45.7) domains were significantly lower than the norm in China. Marital status, capital loss in the earthquake, number of children, level of perceived stress, income, interest, and family harmony each correlated with at least one of the short form WHOQOL-BREF domains in t-test and one-way analyses. After excluding for factor interaction effects using multivariate regression, we found interest, family harmony, monthly income and stress to be significant predictors of physical domain QOL, explaining 13.8% of total variance. Family harmony and interest explained 15.3% of total variance for psychological domain QOL; stress, marital status, family harmony, capital loss in the earthquake, number of children and interest explained 19.5% of total variance for social domain QOL; and stress, family harmony and interest explained 16.5% of total variance for environmental domain QOL. Family harmony and interest were significant factors across all domains, while others influenced a smaller proportion. Quality of life for elderly living in prefab

  16. Expert Consensus Contouring Guidelines for Intensity Modulated Radiation Therapy in Esophageal and Gastroesophageal Junction Cancer

    International Nuclear Information System (INIS)

    Wu, Abraham J.; Bosch, Walter R.; Chang, Daniel T.; Hong, Theodore S.; Jabbour, Salma K.; Kleinberg, Lawrence R.; Mamon, Harvey J.; Thomas, Charles R.; Goodman, Karyn A.

    2015-01-01

    Purpose/Objective(s): Current guidelines for esophageal cancer contouring are derived from traditional 2-dimensional fields based on bony landmarks, and they do not provide sufficient anatomic detail to ensure consistent contouring for more conformal radiation therapy techniques such as intensity modulated radiation therapy (IMRT). Therefore, we convened an expert panel with the specific aim to derive contouring guidelines and generate an atlas for the clinical target volume (CTV) in esophageal or gastroesophageal junction (GEJ) cancer. Methods and Materials: Eight expert academically based gastrointestinal radiation oncologists participated. Three sample cases were chosen: a GEJ cancer, a distal esophageal cancer, and a mid-upper esophageal cancer. Uniform computed tomographic (CT) simulation datasets and accompanying diagnostic positron emission tomographic/CT images were distributed to each expert, and the expert was instructed to generate gross tumor volume (GTV) and CTV contours for each case. All contours were aggregated and subjected to quantitative analysis to assess the degree of concordance between experts and to generate draft consensus contours. The panel then refined these contours to generate the contouring atlas. Results: The κ statistics indicated substantial agreement between panelists for each of the 3 test cases. A consensus CTV atlas was generated for the 3 test cases, each representing common anatomic presentations of esophageal cancer. The panel agreed on guidelines and principles to facilitate the generalizability of the atlas to individual cases. Conclusions: This expert panel successfully reached agreement on contouring guidelines for esophageal and GEJ IMRT and generated a reference CTV atlas. This atlas will serve as a reference for IMRT contours for clinical practice and prospective trial design. Subsequent patterns of failure analyses of clinical datasets using these guidelines may require modification in the future

  17. Assessment and improvement of radiation oncology trainee contouring ability utilizing consensus-based penalty metrics

    International Nuclear Information System (INIS)

    Hallock, Abhirami; Read, Nancy; D'Souza, David

    2012-01-01

    The objective of this study was to develop and assess the feasibility of utilizing consensus-based penalty metrics for the purpose of critical structure and organ at risk (OAR) contouring quality assurance and improvement. A Delphi study was conducted to obtain consensus on contouring penalty metrics to assess trainee-generated OAR contours. Voxel-based penalty metric equations were used to score regions of discordance between trainee and expert contour sets. The utility of these penalty metric scores for objective feedback on contouring quality was assessed by using cases prepared for weekly radiation oncology radiation oncology trainee treatment planning rounds. In two Delphi rounds, six radiation oncology specialists reached agreement on clinical importance/impact and organ radiosensitivity as the two primary criteria for the creation of the Critical Structure Inter-comparison of Segmentation (CriSIS) penalty functions. Linear/quadratic penalty scoring functions (for over- and under-contouring) with one of four levels of severity (none, low, moderate and high) were assigned for each of 20 OARs in order to generate a CriSIS score when new OAR contours are compared with reference/expert standards. Six cases (central nervous system, head and neck, gastrointestinal, genitourinary, gynaecological and thoracic) then were used to validate 18 OAR metrics through comparison of trainee and expert contour sets using the consensus derived CriSIS functions. For 14 OARs, there was an improvement in CriSIS score post-educational intervention. The use of consensus-based contouring penalty metrics to provide quantitative information for contouring improvement is feasible.

  18. Object segmentation using graph cuts and active contours in a pyramidal framework

    Science.gov (United States)

    Subudhi, Priyambada; Mukhopadhyay, Susanta

    2018-03-01

    Graph cuts and active contours are two very popular interactive object segmentation techniques in the field of computer vision and image processing. However, both these approaches have their own well-known limitations. Graph cut methods perform efficiently giving global optimal segmentation result for smaller images. However, for larger images, huge graphs need to be constructed which not only takes an unacceptable amount of memory but also increases the time required for segmentation to a great extent. On the other hand, in case of active contours, initial contour selection plays an important role in the accuracy of the segmentation. So a proper selection of initial contour may improve the complexity as well as the accuracy of the result. In this paper, we have tried to combine these two approaches to overcome their above-mentioned drawbacks and develop a fast technique of object segmentation. Here, we have used a pyramidal framework and applied the mincut/maxflow algorithm on the lowest resolution image with the least number of seed points possible which will be very fast due to the smaller size of the image. Then, the obtained segmentation contour is super-sampled and and worked as the initial contour for the next higher resolution image. As the initial contour is very close to the actual contour, so fewer number of iterations will be required for the convergence of the contour. The process is repeated for all the high-resolution images and experimental results show that our approach is faster as well as memory efficient as compare to both graph cut or active contour segmentation alone.

  19. An evaluation of the contouring abilities of medical dosimetry students for the anatomy of a prostate cancer patient

    International Nuclear Information System (INIS)

    Collins, Kevin S.

    2012-01-01

    Prostate cancer is one of the most common diseases treated in a radiation oncology department. One of the major predictors of the treatment outcome and patient side effects is the accuracy of the anatomical contours for the treatment plan. Therefore, the purpose of this study was to determine which anatomical structures are most often contoured correctly and incorrectly by medical dosimetry students. The author also wanted to discover whether a review of the contouring rules would increase contouring accuracy. To achieve this, a male computed tomography dataset consisting of 72 transverse slices was sent to students for contouring. The students were instructed to import this dataset into their treatment planning system and contour the following structures: skin, bladder, rectum, prostate, penile bulb, seminal vesicles, left femoral head, and right femoral head. Upon completion of the contours, the contour file was evaluated against a “gold standard” contour set using StructSure software (Standard Imaging, Inc). A review of the initial contour results was conducted and then students were instructed to contour the dataset a second time. The results of this study showed significant differences between contouring sessions. These results and the standardization of contouring rules should benefit all individuals who participate in the treatment planning of cancer patients.

  20. 3D Filament Network Segmentation with Multiple Active Contours

    Science.gov (United States)

    Xu, Ting; Vavylonis, Dimitrios; Huang, Xiaolei

    2014-03-01

    Fluorescence microscopy is frequently used to study two and three dimensional network structures formed by cytoskeletal polymer fibers such as actin filaments and microtubules. While these cytoskeletal structures are often dilute enough to allow imaging of individual filaments or bundles of them, quantitative analysis of these images is challenging. To facilitate quantitative, reproducible and objective analysis of the image data, we developed a semi-automated method to extract actin networks and retrieve their topology in 3D. Our method uses multiple Stretching Open Active Contours (SOACs) that are automatically initialized at image intensity ridges and then evolve along the centerlines of filaments in the network. SOACs can merge, stop at junctions, and reconfigure with others to allow smooth crossing at junctions of filaments. The proposed approach is generally applicable to images of curvilinear networks with low SNR. We demonstrate its potential by extracting the centerlines of synthetic meshwork images, actin networks in 2D TIRF Microscopy images, and 3D actin cable meshworks of live fission yeast cells imaged by spinning disk confocal microscopy.

  1. Lung segmentation from HRCT using united geometric active contours

    Science.gov (United States)

    Liu, Junwei; Li, Chuanfu; Xiong, Jin; Feng, Huanqing

    2007-12-01

    Accurate lung segmentation from high resolution CT images is a challenging task due to various detail tracheal structures, missing boundary segments and complex lung anatomy. One popular method is based on gray-level threshold, however its results are usually rough. A united geometric active contours model based on level set is proposed for lung segmentation in this paper. Particularly, this method combines local boundary information and region statistical-based model synchronously: 1) Boundary term ensures the integrality of lung tissue.2) Region term makes the level set function evolve with global characteristic and independent on initial settings. A penalizing energy term is introduced into the model, which forces the level set function evolving without re-initialization. The method is found to be much more efficient in lung segmentation than other methods that are only based on boundary or region. Results are shown by 3D lung surface reconstruction, which indicates that the method will play an important role in the design of computer-aided diagnostic (CAD) system.

  2. The Development of Skull Prosthesis Through Active Contour Model.

    Science.gov (United States)

    Chen, Yi-Wen; Shih, Cheng-Ting; Cheng, Chen-Yang; Lin, Yu-Cheng

    2017-09-09

    Skull defects result in brain infection and inadequate brain protection and pose a general danger to patient health. To avoid these situations and prevent re-injury, a prosthesis must be constructed and grafted onto the deficient region. With the development of rapid customization through additive manufacturing and 3D printing technology, skull prostheses can be fabricated accurately and efficiently prior to cranioplasty. However, an unfitted skull prosthesis made with a metal implant can cause repeated infection, potentially necessitating secondary surgery. This paper presents a method of creating suitably geometric graphics of skull defects to be applied in skull repair through active contour models. These models can be adjusted in each computed tomography slice according to the graphic features, and the curves representing the skull defect can be modeled. The generated graphics can adequately mimic the natural curvature of the complete skull. This method will enable clinical surgeons to rapidly implant customized prostheses, which is of particular importance in emergency surgery. The findings of this research can help surgeons provide patients with skull defects with treatment of the highest quality.

  3. A review: aluminum nitride MEMS contour-mode resonator

    Science.gov (United States)

    Yunhong, Hou; Meng, Zhang; Guowei, Han; Chaowei, Si; Yongmei, Zhao; Jin, Ning

    2016-10-01

    Over the past several decades, the technology of micro-electromechanical system (MEMS) has advanced. A clear need of miniaturization and integration of electronics components has had new solutions for the next generation of wireless communications. The aluminum nitride (AlN) MEMS contour-mode resonator (CMR) has emerged and become promising and competitive due to the advantages of the small size, high quality factor and frequency, low resistance, compatibility with integrated circuit (IC) technology, and the ability of integrating multi-frequency devices on a single chip. In this article, a comprehensive review of AlN MEMS CMR technology will be presented, including its basic working principle, main structures, fabrication processes, and methods of performance optimization. Among these, the deposition and etching process of the AlN film will be specially emphasized and recent advances in various performance optimization methods of the CMR will be given through specific examples which are mainly focused on temperature compensation and reducing anchor losses. This review will conclude with an assessment of the challenges and future trends of the CMR. Project supported by National Natural Science Foundation (Nos. 61274001, 61234007, 61504130), the Nurturing and Development Special Projects of Beijing Science and Technology Innovation Base's Financial Support (No. Z131103002813070), and the National Defense Science and Technology Innovation Fund of CAS (No. CXJJ-14-M32).

  4. Multiphase Interface Tracking with Fast Semi-Lagrangian Contouring.

    Science.gov (United States)

    Li, Xiaosheng; He, Xiaowei; Liu, Xuehui; Zhang, Jian J; Liu, Baoquan; Wu, Enhua

    2016-08-01

    We propose a semi-Lagrangian method for multiphase interface tracking. In contrast to previous methods, our method maintains an explicit polygonal mesh, which is reconstructed from an unsigned distance function and an indicator function, to track the interface of arbitrary number of phases. The surface mesh is reconstructed at each step using an efficient multiphase polygonization procedure with precomputed stencils while the distance and indicator function are updated with an accurate semi-Lagrangian path tracing from the meshes of the last step. Furthermore, we provide an adaptive data structure, multiphase distance tree, to accelerate the updating of both the distance function and the indicator function. In addition, the adaptive structure also enables us to contour the distance tree accurately with simple bisection techniques. The major advantage of our method is that it can easily handle topological changes without ambiguities and preserve both the sharp features and the volume well. We will evaluate its efficiency, accuracy and robustness in the results part with several examples.

  5. The forgotten foot - an assessment of foot and ankle radiograph pathology in final year medical students.

    LENUS (Irish Health Repository)

    Groarke, P J

    2014-04-27

    It has been shown that doctors in Emergency Departments (EDs) have inconsistent knowledge of musculoskeletal anatomy. This is most likely due to a deficiency in focused musculoskeletal modules at undergraduate level in medical school. The aims of this study were to evaluate the knowledge of final year medical students on foot anatomy and common foot and ankle pathology as seen on radiographs.

  6. In-hospital costs of diabetic foot disease treated by a multidisciplinary foot team

    NARCIS (Netherlands)

    Rinkel, Willem D.; Luiten, Jacky; van Dongen, Jelle; Kuppens, Bram; Van Neck, Johan W.; Polinder, Suzanne; Castro Cabezas, Manuel; Coert, J. Henk

    2017-01-01

    Background The diabetic foot imposes significant burden on healthcare systems. Obtaining knowledge on the extent of the costs of diabetic foot ulcers (DFUs) is of value to health care researchers investigating cost-effectiveness of interventions that prevent these costly complications. Objectives To

  7. Repeatability of the Oxford Foot Model for Kinematic Gait Analysis of the Foot and Ankle

    NARCIS (Netherlands)

    van Hoeve, S.; Vos, J.; Weijers, P.; Verbruggen, J.; Willems, P.; Poeze, M.; Meijer, K.

    2015-01-01

    INTRODUCTION: Kinematic gait analysis via the multi-segmental Oxford foot model (OFM) may be a valuable addition to the biomechanical examination of the foot and ankle. The aim of this study is to assess the repeatability of the OFM in healthy subjects. METHODS: Nine healthy subjects, without a

  8. Magnitude and Spatial Distribution of Impact Intensity Under the Foot Relates to Initial Foot Contact Pattern.

    Science.gov (United States)

    Breine, Bastiaan; Malcolm, Philippe; Segers, Veerle; Gerlo, Joeri; Derie, Rud; Pataky, Todd; Frederick, Edward C; De Clercq, Dirk

    2017-12-01

    In running, foot contact patterns (rear-, mid-, or forefoot contact) influence impact intensity and initial ankle and foot kinematics. The aim of the study was to compare impact intensity and its spatial distribution under the foot between different foot contact patterns. Forty-nine subjects ran at 3.2 m·s -1 over a level runway while ground reaction forces (GRF) and shoe-surface pressures were recorded and foot contact pattern was determined. A 4-zone footmask (forefoot, midfoot, medial and lateral rearfoot) assessed the spatial distribution of the vertical GRF under the foot. We calculated peak vertical instantaneous loading rate of the GRF (VILR) per foot zone as the impact intensity measure. Midfoot contact patterns were shown to have the lowest, and atypical rearfoot contact patterns the highest impact intensities, respectively. The greatest local impact intensity was mainly situated under the rear- and midfoot for the typical rearfoot contact patterns, under the midfoot for the atypical rearfoot contact patterns, and under the mid- and forefoot for the midfoot contact patterns. These findings indicate that different foot contact patterns could benefit from cushioning in different shoe zones.

  9. COMPARISON OF GAIT USING A MULTIFLEX FOOT VERSUS A QUANTUM FOOT IN KNEE DISARTICULATION AMPUTEES

    NARCIS (Netherlands)

    BOONSTRA, AM; FIDLER, [No Value; SPITS, GMA; HOF, AL; Tuil, P.

    The subjective responses and gait patterns of unilateral knee disarticulation amputees wearing prostheses fitted first with the Multiflex foot and then with the Quantum foot were studied. Nine amputees were included in the trial. A questionnaire asked the amputees about their preference for one of

  10. From the diabetic foot ulcer and beyond: how do foot infections spread in patients with diabetes?

    Science.gov (United States)

    Aragón-Sánchez, Javier; Lázaro-Martínez, Jose Luis; Pulido-Duque, Juan; Maynar, Manuel

    2012-01-01

    A diabetic foot infection is usually the result of a pre-existing foot ulceration and is the leading cause of lower extremity amputation in patients with diabetes. It is widely accepted that diabetic foot infections may be challenging to treat for several reasons. The devastating effects of hyperglycemia on host defense, ischemia, multi-drug resistant bacteria and spreading of infection through the foot may complicate the course of diabetic foot infections. Understanding the ways in which infections spread through the diabetic foot is a pivotal factor in order to decide the best approach for the patient's treatment. The ways in which infections spread can be explained by the anatomical division of the foot into compartments, the tendons included in the compartments, the initial location of the point of entry of the infection and the type of infection that the patient has. The aim of this paper is to further comment on the existed and proposed anatomical principles of the spread of infection through the foot in patients with diabetes. PMID:23050067

  11. The validity and accuracy in foot-to-foot bioelectrical impedance ...

    African Journals Online (AJOL)

    The validity and accuracy in foot-to-foot bioelectrical impedance analysis measuring models referenced by dual-energy X-ray absorptiometry in body composition in standing position. KC Hsieh, HK Lu, CH Chen, TR Jang, YY Chen, MF Kao ...

  12. Statistical Modeling Approach to Quantitative Analysis of Interobserver Variability in Breast Contouring

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Jinzhong, E-mail: jyang4@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Woodward, Wendy A.; Reed, Valerie K.; Strom, Eric A.; Perkins, George H.; Tereffe, Welela; Buchholz, Thomas A. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Zhang, Lifei; Balter, Peter; Court, Laurence E. [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Li, X. Allen [Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States); Dong, Lei [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Scripps Proton Therapy Center, San Diego, California (United States)

    2014-05-01

    Purpose: To develop a new approach for interobserver variability analysis. Methods and Materials: Eight radiation oncologists specializing in breast cancer radiation therapy delineated a patient's left breast “from scratch” and from a template that was generated using deformable image registration. Three of the radiation oncologists had previously received training in Radiation Therapy Oncology Group consensus contouring for breast cancer atlas. The simultaneous truth and performance level estimation algorithm was applied to the 8 contours delineated “from scratch” to produce a group consensus contour. Individual Jaccard scores were fitted to a beta distribution model. We also applied this analysis to 2 or more patients, which were contoured by 9 breast radiation oncologists from 8 institutions. Results: The beta distribution model had a mean of 86.2%, standard deviation (SD) of ±5.9%, a skewness of −0.7, and excess kurtosis of 0.55, exemplifying broad interobserver variability. The 3 RTOG-trained physicians had higher agreement scores than average, indicating that their contours were close to the group consensus contour. One physician had high sensitivity but lower specificity than the others, which implies that this physician tended to contour a structure larger than those of the others. Two other physicians had low sensitivity but specificity similar to the others, which implies that they tended to contour a structure smaller than the others. With this information, they could adjust their contouring practice to be more consistent with others if desired. When contouring from the template, the beta distribution model had a mean of 92.3%, SD ± 3.4%, skewness of −0.79, and excess kurtosis of 0.83, which indicated a much better consistency among individual contours. Similar results were obtained for the analysis of 2 additional patients. Conclusions: The proposed statistical approach was able to measure interobserver variability quantitatively

  13. SU-E-J-108: Solving the Chinese Postman Problem for Effective Contour Deformation

    Energy Technology Data Exchange (ETDEWEB)

    Yang, J; Zhang, L; Balter, P; Court, L [MD Anderson Cancer Center, Houston, TX (United States); Zhang, Y; Dong, L [Scripps Proton Therapy Center, San Diego, CA (United States)

    2015-06-15

    Purpose: To develop a practical approach for accurate contour deformation when deformable image registration (DIR) is used for atlas-based segmentation or contour propagation in image-guided radiotherapy. Methods: A contour deformation approach was developed on the basis of 3D mesh operations. The 2D contours represented by a series of points in each slice were first converted to a 3D triangular mesh, which was deformed by the deformation vectors resulting from DIR. A set of parallel 2D planes then cut through the deformed 3D mesh, generating unordered points and line segments, which should be reorganized into a set of 2D contour points. It was realized that the reorganization problem was equivalent to solving the Chinese Postman Problem (CPP) by traversing a graph built from the unordered points with the least cost. Alternatively, deformation could be applied to a binary mask converted from the original contours. The deformed binary mask was then converted back into contours at the CT slice locations. We performed a qualitative comparison to validate the mesh-based approach against the image-based approach. Results: The DIR could considerably change the 3D mesh, making complicated 2D contour representations after deformation. CPP was able to effectively reorganize the points in 2D planes no matter how complicated the 2D contours were. The mesh-based approach did not require a post-processing of the contour, thus accurately showing the actual deformation in DIR. The mesh-based approach could keep some fine details and resulted in smoother contours than the image-based approach did, especially for the lung structure. Image-based approach appeared to over-process contours and suffered from image resolution limits. The mesh-based approach was integrated into in-house DIR software for use in routine clinic and research. Conclusion: We developed a practical approach for accurate contour deformation. The efficiency of this approach was demonstrated in both clinic and

  14. One-Piece Implant-Retained Mandibular Overdentures By Pre-Fabricated Titanium Telescopic Attachments and Frictional Varnish: A Two-Year Prospective Study.

    Science.gov (United States)

    Nik, Shahram Namjoy; Nejatian, Touraj

    2016-12-01

    Clinical efficiency of one-piece screw-type implants with telescopic were attachments evaluated in this study. Twenty-four patients received a mandibular implant-supported overdenture and maxillary complete denture. Ninety-six one-piece implants were inserted in the inter-foraminal area. Implants were immediately loaded with an implant-retained overdenture and telescopic attachments which had frictional retention elements. There was 0.25±0.24 mm, 0.32±0.25 mm, 0.43±0.30 mm, 0.61±0.30 mm and of bone resorption after 3, 6, 12 and 24 months, respectively. The need to activate the frictional retention was the most common complication. Treatment outcomes for prefabricated telescopic retained overdentures on one-piece implants are similar to that obtained in cases of delayed loading. Copyright© 2016 Dennis Barber Ltd.

  15. Nineteen-Foot Diameter Explosively Driven Blast Simulator; TOPICAL

    International Nuclear Information System (INIS)

    VIGIL, MANUEL G.

    2001-01-01

    This report describes the 19-foot diameter blast tunnel at Sandia National Laboratories. The blast tunnel configuration consists of a 6 foot diameter by 200 foot long shock tube, a 6 foot diameter to 19 foot diameter conical expansion section that is 40 feet long, and a 19 foot diameter test section that is 65 feet long. Therefore, the total blast tunnel length is 305 feet. The development of this 19-foot diameter blast tunnel is presented. The small scale research test results using 4 inch by 8 inch diameter and 2 foot by 6 foot diameter shock tube facilities are included. Analytically predicted parameters are compared to experimentally measured blast tunnel parameters in this report. The blast tunnel parameters include distance, time, static, overpressure, stagnation pressure, dynamic pressure, reflected pressure, shock Mach number, flow Mach number, shock velocity, flow velocity, impulse, flow duration, etc. Shadowgraphs of the shock wave are included for the three different size blast tunnels

  16. Foot roll-over evaluation based on 3D dynamic foot scan.

    Science.gov (United States)

    Samson, William; Van Hamme, Angèle; Sanchez, Stéphane; Chèze, Laurence; Van Sint Jan, Serge; Feipel, Véronique

    2014-01-01

    Foot roll-over is commonly analyzed to evaluate gait pathologies. The current study utilized a dynamic foot scanner (DFS) to analyze foot roll-over. The right feet of ten healthy subjects were assessed during gait trials with a DFS system integrated into a walkway. A foot sole picture was computed by vertically projecting points from the 3D foot shape which were lower than a threshold height of 15 mm. A 'height' value of these projected points was determined; corresponding to the initial vertical coordinates prior to projection. Similar to pedobarographic analysis, the foot sole picture was segmented into anatomical regions of interest (ROIs) to process mean height (average of height data by ROI) and projected surface (area of the projected foot sole by ROI). Results showed that these variables evolved differently to plantar pressure data previously reported in the literature, mainly due to the specificity of each physical quantity (millimeters vs Pascals). Compared to plantar pressure data arising from surface contact by the foot, the current method takes into account the whole plantar aspect of the foot, including the parts that do not make contact with the support surface. The current approach using height data could contribute to a better understanding of specific aspects of foot motion during walking, such as plantar arch height and the windlass mechanism. Results of this study show the underlying method is reliable. Further investigation is required to validate the DFS measurements within a clinical context, prior to implementation into clinical practice. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Beyond the Bottom of the Foot: Topographic Organization of the Foot Dorsum in Walking.

    Science.gov (United States)

    Klarner, Taryn; Pearcey, Gregory E P; Sun, Yao; Barss, Trevor S; Kaupp, Chelsea; Munro, Bridget; Frank, Nick; Zehr, E Paul

    2017-12-01

    Sensory feedback from the foot dorsum during walking has only been studied globally by whole nerve stimulation. Stimulating the main nerve innervating the dorsal surface produces a functional stumble corrective response that is phase-dependently modulated. We speculated that effects evoked by activation of discrete skin regions on the foot dorsum would be topographically organized, as with the foot sole. Nonnoxious electrical stimulation was delivered to five discrete locations on the dorsal surface of the foot during treadmill walking. Muscle activity from muscles acting at the ankle, knee, hip, and shoulder were recorded along with ankle, knee, and hip kinematics and kinetic information from forces under the foot. All data were sorted on the basis of stimulus occurrence in 12 step cycle phases, before being averaged together within a phase for subsequent analysis. Results reveal dynamic changes in reflex amplitudes and kinematics that are site specific and phase dependent. Most responses from discrete sites on the foot dorsum were seen in the swing phase suggesting function to conform foot trajectory to maintain stability of the moving limb. In general, responses from lateral stimulation differed from medial stimulation, and effects were largest from stimulation at the distal end of the foot at the metatarsals; that is, in anatomical locations where actual impact with an object in the environment is most likely during swing. Responses to stimulation extend to include muscles at the hip and shoulder. We reveal that afferent feedback from specific cutaneous locations on the foot dorsum influences stance and swing phase corrective responses. This emphasizes the critical importance of feedback from the entire foot surface in locomotor control and has application for rehabilitation after neurological injury and in footwear development.

  18. Perbaikan Tanah Dasar Menggunakan Pre-Fabricated Vertical Drain Dengan Variasi Kedalaman Dan Perkuatan Lereng Dengan Turap Studi Kasus : Lapangan Penumpukan Peti Kemas, Pelabuhan Trisakti, Banjarmasin, Kalimantan Selatan

    Directory of Open Access Journals (Sweden)

    Dofran Winner

    2017-03-01

    Full Text Available Metode perbaikan tanah dasar menggunakan preloading yang dikombinasikan dengan Pre-fabricated Vertical Drain (PVD dipilih untuk proyek pengembangan lapangan penumpukan peti kemas di Pelabuhan Trisakti, Banjarmasin, Kalimantan Selatan. Selama masa preloading, ternyata kelongsoran selebar 37 meter terjadi di area penumpukan. Diketahui bahwa kelongsoran terjadi saat preloading setinggi 4,0 meter. Agar lapangan penumpukan dapat beroperasi kembali, diperlukan perencanaan untuk perkuatan lereng dan untuk menghilangkan pemampatan tanah dasar di area lapangan penumpukan. Perbaikan tanah dasar menggunakan preloading yang dikombinasikan dengan Pre-fabricated Vertical Drain (PVD digunakan untuk Zona 3, 4, dan 5, dan perkuatan lereng dengan turap digunakan untuk Zona-1 dan Zona-2 yang merupakan bagian lereng dari lapangan penumpukan. Direncanakan PVD dipasang pada kedalaman yang berbeda: 1/3H, 2/3H, dan H (H adalah ketebalan lapisan tanah lunak untuk melihat kondisi yang menghasilkan biaya paling murah. Dari hasil perencanaan yang dilakukan, diketahui bahwa turap yang digunakan adalah Corrugated Concrete sheet pile type W-600 A1000. Turap dipasang sedalam 18 meter di Zona-1 dan sedalam 22 meter di Zona-2; selain itu, angker dipasang pada turap untuk meningkatkan kekakuan turap. Hasil perencanaan juga menunjukkan bahwa biaya yang paling ekonomis adalah PVD dipasang sampai 2/3H di Zona-3, dan tanpa PVD di Zona-4 dan Zona-5. Total biaya konstruksi adalah sebesar Rp 843.106.053,00 untuk Zona-1 dan Zona-2; Rp 9.446.530.597,00 untuk Zona-3; Rp 1.869.613.200,00 untuk Zona 4; dan Rp 3.577.392.000,00 untuk Zona 5.

  19. Contributions of contour frequency, amplitude, and luminance to the watercolor effect estimated by conjoint measurement.

    Science.gov (United States)

    Gerardin, Peggy; Devinck, Frédéric; Dojat, Michel; Knoblauch, Kenneth

    2014-04-10

    The watercolor effect is a long-range, assimilative, filling-in phenomenon induced by a pair of distant, wavy contours of different chromaticities. Here, we measured joint influences of the contour frequency and amplitude and the luminance of the interior contour on the strength of the effect. Contour pairs, each enclosing a circular region, were presented with two of the dimensions varying independently across trials (luminance/frequency, luminance/amplitude, frequency/amplitude) in a conjoint measurement paradigm (Luce & Tukey, 1964). In each trial, observers judged which of the stimuli evoked the strongest fill-in color. Control stimuli were identical except that the contours were intertwined and generated little filling-in. Perceptual scales were estimated by a maximum likelihood method (Ho, Landy, & Maloney, 2008). An additive model accounted for the joint contributions of any pair of dimensions. As shown previously using difference scaling (Devinck & Knoblauch, 2012), the strength increases with luminance of the interior contour. The strength of the phenomenon was nearly independent of the amplitude of modulation of the contour but increased with its frequency up to an asymptotic level. On average, the strength of the effect was similar along a given dimension regardless of the other dimension with which it was paired, demonstrating consistency of the underlying estimated perceptual scales.

  20. Technical report on the surface reconstruction of stacked contours by using the commercial software

    Science.gov (United States)

    Shin, Dong Sun; Chung, Min Suk; Hwang, Sung Bae; Park, Jin Seo

    2007-03-01

    After drawing and stacking contours of a structure, which is identified in the serially sectioned images, three-dimensional (3D) image can be made by surface reconstruction. Usually, software is composed for the surface reconstruction. In order to compose the software, medical doctors have to acquire the help of computer engineers. So in this research, surface reconstruction of stacked contours was tried by using commercial software. The purpose of this research is to enable medical doctors to perform surface reconstruction to make 3D images by themselves. The materials of this research were 996 anatomic images (1 mm intervals) of left lower limb, which were made by serial sectioning of a cadaver. On the Adobe Photoshop, contours of 114 anatomic structures were drawn, which were exported to Adobe Illustrator files. On the Maya, contours of each anatomic structure were stacked. On the Rhino, superoinferior lines were drawn along all stacked contours to fill quadrangular surfaces between contours. On the Maya, the contours were deleted. 3D images of 114 anatomic structures were assembled with their original locations preserved. With the surface reconstruction technique, developed in this research, medical doctors themselves could make 3D images of the serially sectioned images such as CTs and MRIs.