WorldWideScience

Sample records for continuous sterilization system

  1. Alcohol production from sterilized and non-sterilized molasses by Saccharomyces cerevisiae immobilized on brewer's spent grains in two types of continuous bioreactor systems

    International Nuclear Information System (INIS)

    Kopsahelis, Nikolaos; Bosnea, Loulouda; Bekatorou, Argyro; Tzia, Constantina; Kanellaki, Maria

    2012-01-01

    In this work an integrated cost effective system for continuous alcoholic fermentation of a cheap raw material (molasses) is described, involving yeast immobilized by a simple method on brewer's spent grains, able to ferment in the temperature range 30–40 °C, and two types of bioreactors, a Multistage Fixed Bed Tower (MFBT) and a Packed Bed reactor (PB). The MFBT bioreactor gave better results regarding ethanol concentration, productivity and conversion. Furthermore, the use of sterilized and non-sterilized molasses, fed in two similar MFBT bioreactors, showed that ethanol concentration (kg m −3 ) was significantly (p −3 at 35 °C and 44.2–48.2 kg m −3 at 40 °C), compared to sterilized molasses, where ethanol concentration ranged from 35.6 to 46.6 kg m −3 at 35 °C and 30.8–44.2 kg m −3 at 40 °C. During 32 days of continuous operation using non-sterilized molasses no contamination was observed. Industrialization of the proposed system seems to have a potential, mainly due to its high fermentation efficiency and the obtained high operational stability. -- Highlights: ► An integrated cost effective system for continuous alcoholic fermentation. ► Efficient conversion of non-sterilized molasses to ethanol. ► No need for additional treatments to prevent contamination. ► Results showed high fermentation efficiency and high operational stability.

  2. Red oak borers become sterile when reared under continuous light

    Science.gov (United States)

    Jimmy R. Galford

    1975-01-01

    Red oak borers, Enaphalodes rufulus (Haldeman), reared under continuous light for 12 weeks became sterile. Sterility is thought to have been caused by light destroying vitamins essential for fertility

  3. Sterility among female lizards (Uta stansburiana) exposed to continuous γ irradiation

    International Nuclear Information System (INIS)

    Turner, F.B.; Medica, P.A.

    1977-01-01

    A natural population of the lizard Uta stansburiana occupying a fenced 9-ha area in southern Nevada was exposed to essentially continuous γ irradiation from an arificial source between February 1964 and September 1973. Tissue doses were estimated using implanted lithium fluoride microdosimeters. Females became sterile as early as 11 months of age, but many were still fertile at ages of 20 months and a very few may have reproduced at 32 months. Dosimetry showed some females to be sterile after accumulated doses of around 500 rad, while others may have required 1000 or more rad. One female estimated to have received over 1200 rad was still reproductive. Irradiated females may pass through a state of half sterility, during which time they possess one functional ovary. Female U. stansburiana are sterilized at lower doses than the sterilizing dose (1500 rad) previously suggested for the leopard lizard, Crotaphytus wislizenii

  4. Development and Validation of Sterility Systems for Trees

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, Steve; Shevchenko, Olga; Ma, Caiping (Cathleen)

    2007-03-30

    The overall goal of this project was to develop and validate sterility systems in poplar with the ultimate goal of fulfilling the basic requirements for commercial use. For this, sterility must be complete and stable over multiple growing seasons, cause no detrimental effects on vegetative growth, and successful transformation events must be identifiable via molecular tests when trees are still juvenile. Because of the inherent difficulties in achieving and demonstrating complete sterility in trees, our approach was to study alternate sterility systems in Arabidopsis and/or early-flowering tree systems. The public benefit from this work is the capacity for containment of genes or exotic forms of trees so they can be of benefit for industry for production of wood, energy, and renewable products, while having minimal impact on wild populations of trees. We tested three methods for engineering sterility: dominant negative mutant (DNM) proteins, floral tissue ablation, and RNA interference (RNAi) to suppress the expression of several floral regulatory genes. The ultimate goal of this work was to produce a number of transgenic poplars that could be outplanted to enable future assessments of the effectiveness of these transgenic sterility methods. Our attempts to produce ablation constructs that did not interfere with tree health were partially successful. Using the poplar LEAFY gene promoter and the barnase/barstar system, we were able to regenerate plants that grew well in the greenhouse, but they showed poor health in the field. Four of seven DNM genes tested were considered promising enough, based on results in Arabidopsis, to produce transgenic poplars. Single, double, and triple RNAi genes were produced and transformed into poplar. Over all, we produced 1,964 PCR-confirmed transgenic events with 19 different kinds of sterility genes and several kinds of control genes. We propagated 5,640, 6,820, and 7,055 trees for each of three test poplar genotypes, and field

  5. Pain Associated With Hysteroscopic Sterilization

    Science.gov (United States)

    Levy, Jenna; Childers, Meredith E.

    2007-01-01

    Background and Objectives: The safety and efficacy of female hysteroscopic sterilization using the Essure system has been well documented. Given the marked differences in the execution of hysteroscopic and laparoscopic sterilization, the objective of this study was to assess the experience of pain postprocedure between the 2. Secondary end-points included postoperative pain medication, time to return to normal activities, postprocedure bleeding, and patient satisfaction. Methods: Twenty cases each of laparoscopic sterilization (LS) and hysteroscopic sterilization (HS) were performed. Patients were surveyed regarding their experience of pain immediately postoperatively, 1 week, and 4 weeks post-procedure. Results: The average pain score immediately postprocedure was significantly lower among HS patients than among LS patients (t=−8.17, P<.0001). One-week post-procedure, none of the patients in the HS group reported any pain, while the average pain score among the LS patients was 2.65 (t =−9.67, P<.0001). Four weeks post-procedure, women in the HS group continued to report no pain, 35% of the LS group continued to report some pain (t=−3.04, P=.004). Conclusions: Hysteroscopic sterilization offers a minimally invasive, less painful, equally efficacious modality for sterilization than laparoscopic sterilization and should be available to all women seeking permanent birth control. PMID:17651558

  6. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene

    OpenAIRE

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-01-01

    Nuclear male sterility is common in flowering plants, but its application in hybrid breeding and seed production is limited because of the inability to propagate a pure male sterile line for commercial hybrid seed production. Here, we characterized a rice nuclear gene essential for sporophytic male fertility and constructed a male sterility system that can propagate the pure male sterile seeds on a large scale. This system is fundamentally advantageous over the current cytoplasmic male steril...

  7. Hysteroscopic tubal sterilization: a systematic review of the Essure system

    DEFF Research Database (Denmark)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika

    2010-01-01

    OBJECTIVE: To update the evidence of the efficacy and safety of the Essure system. Female sterilization has undergone changes in the last decade. Besides laparoscopic tubal occlusion, the Essure system is now a viable option, with about 200,000 women sterilized using this method. DESIGN: The review...... in ambulatory settings. However, sterilization is not immediate and women must use additional contraception for 3 months until permanent tubal occlusion is verified by transvaginal ultrasound, hysterosalpingosonography, hysterosalpingography, or pelvic radiography. The evidence on efficacy and safety is mainly...... sterilization, but more information on the total cost is needed. CONCLUSION(S): The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published...

  8. Portable Decontamination and Sterilization System

    National Research Council Canada - National Science Library

    Bell, William; Smerjac, Suzanne; Smith, Bryan

    2004-01-01

    TDA Research, Inc., (TDA) is developing a portable system to generate chlorine dioxide, which can be used for biodecontamination of small items and to sterilize medical and dental instruments in austere environments...

  9. Gamma-sterilization-induced radicals in biodegradable drug delivery systems

    International Nuclear Information System (INIS)

    Maeder, K.; Swartz, H.M.; Domb, A.

    1996-01-01

    Electron paramagnetic resonance (EPR) spectroscopy (1.2 and 9.25 GHz, 25 o C) was used to characterize free radicals in gamma-ray sterilized biodegradable polymers of the type which are in clinical use. Free radicals were detected in all irradiated polymer samples. The temperature of irradiation (25 o vs dry ice temperature) had only a minor influence on the yield of radicals and the shape of the EPR spectra. In contrast, the composition of the polymers and the drugs incorporated in them did strongly influence the amount of radiation-induced free radicals and their reactivity. In general, polymers with high melting points and crystallinity had the highest yields of radicals observable at room temperature. We were able to use the free radicals induced by the usual sterilization procedures to follow the penetration of water and the degradation of the polymers in vitro and in vivo. The ability of in vivo EPR to follow drug delivery noninvasively and continuously in vivo, using the free radicals induced in the usual sterilization process indicates that this approach could be applied immediately for the characterization of these drug delivery systems in experimental animals and in the near future should be able to be used in human subjects. (author)

  10. Hysteroscopic tubal sterilization: a systematic review of the Essure system.

    Science.gov (United States)

    Hurskainen, Ritva; Hovi, Sirpa-Liisa; Gissler, Mika; Grahn, Riitta; Kukkonen-Harjula, Katriina; Nord-Saari, Merja; Mäkelä, Marjukka

    2010-06-01

    To update the evidence of the efficacy and safety of the Essure system. Female sterilization has undergone changes in the last decade. Besides laparoscopic tubal occlusion, the Essure system is now a viable option, with about 200,000 women sterilized using this method. The review is based on the report of the Alberta Heritage Foundation for Medical Research and completed with systematic literature searches up to April 8, 2008. The Managed Uptake of Medical Methods program of the Finnish National Research and Development Center for Health and Welfare. Women over 30 years, who had been sterilized by the Essure method. Hysteroscopic tubal sterilization using Essure system. Efficacy/effectiveness, adverse events, costs. Sterilization by Essure can be performed under local anesthesia or with oral analgesics in ambulatory settings. However, sterilization is not immediate and women must use additional contraception for 3 months until permanent tubal occlusion is verified by transvaginal ultrasound, hysterosalpingosonography, hysterosalpingography, or pelvic radiography. The evidence on efficacy and safety is mainly available from short follow-up case series but shows good efficacy and safety of the Essure system. Only a few small risks are associated with the procedure. Two economic studies, one of which implemented Essure as an in-office procedure, suggest that Essure could be more cost-effective than laparoscopic sterilization, but more information on the total cost is needed. The Essure system appears to be safe, permanent, irreversible, and a less invasive method of contraception compared with laparoscopic sterilization. Copyright (c) 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  11. Current systems of sterilization in the Philippines in both government and private hospitals

    International Nuclear Information System (INIS)

    Lim, L.E.

    1996-01-01

    In the Philippines, there are 1,700 registered hospitals, both private and government. There are 80,000 beds. The systems of sterilization are mainly using steam or to use ethylene oxide sterilization. Gamma ray sterilization is purely on experimental basis and very limited scale for industrial products. The author will trace the history of sterilization, practised since a century ago and trace back to the present system of sterilization. The principles applied, precautions and limitations or advantages of the different systems will be discussed particularly steam sterilization and ethylene oxide. Other forms of sterilization either chemical or physical will be discussed in passing. Experience in gamma ray sterilization in Japan and Australia will be presented when available data are obtained, to encourage local investors to engage in such venture. Philippines has been left behind by our neighbors. (author)

  12. Quality comparison of continuous steam sterilization segmented-flow aseptic processing versus conventional canning of whole and sliced mushrooms.

    Science.gov (United States)

    Anderson, N M; Walker, P N

    2011-08-01

    This study was carried out to investigate segmented-flow aseptic processing of particle foods. A pilot-scale continuous steam sterilization unit capable of producing shelf stable aseptically processed whole and sliced mushrooms was developed. The system utilized pressurized steam as the heating medium to achieve high temperature-short time processing conditions with high and uniform heat transfer that will enable static temperature penetration studies for process development. Segmented-flow technology produced a narrower residence time distribution than pipe-flow aseptic processing; thus, whole and sliced mushrooms were processed only as long as needed to achieve the target F₀  = 7.0 min and were not overcooked. Continuous steam sterilization segmented-flow aseptic processing produced shelf stable aseptically processed mushrooms of superior quality to conventionally canned mushrooms. When compared to conventionally canned mushrooms, aseptically processed yield (weight basis) increased 6.1% (SD = 2.9%) and 6.6% (SD = 2.2%), whiteness (L) improved 3.1% (SD = 1.9%) and 4.7% (SD = 0.7%), color difference (ΔE) improved 6.0% (SD = 1.3%) and 8.5% (SD = 1.5%), and texture improved 3.9% (SD = 1.7%) and 4.6% (SD = 4.2%), for whole and sliced mushrooms, respectively. Segmented-flow aseptic processing eliminated a separate blanching step, eliminated the unnecessary packaging of water and promoted the use of bag-in-box and other versatile aseptic packaging methods. Segmented-flow aseptic processing is capable of producing shelf stable aseptically processed particle foods of superior quality to a conventionally canned product. This unique continuous steam sterilization process eliminates the need for a separate blanching step, reduces or eliminates the need for a liquid carrier, and promotes the use of bag-in-box and other versatile aseptic packaging methods. © 2011 Institute of Food Technologists®

  13. Construction of a male sterility system for hybrid rice breeding and seed production using a nuclear male sterility gene.

    Science.gov (United States)

    Chang, Zhenyi; Chen, Zhufeng; Wang, Na; Xie, Gang; Lu, Jiawei; Yan, Wei; Zhou, Junli; Tang, Xiaoyan; Deng, Xing Wang

    2016-12-06

    The breeding and large-scale adoption of hybrid seeds is an important achievement in agriculture. Rice hybrid seed production uses cytoplasmic male sterile lines or photoperiod/thermo-sensitive genic male sterile lines (PTGMS) as female parent. Cytoplasmic male sterile lines are propagated via cross-pollination by corresponding maintainer lines, whereas PTGMS lines are propagated via self-pollination under environmental conditions restoring male fertility. Despite huge successes, both systems have their intrinsic drawbacks. Here, we constructed a rice male sterility system using a nuclear gene named Oryza sativa No Pollen 1 (OsNP1). OsNP1 encodes a putative glucose-methanol-choline oxidoreductase regulating tapetum degeneration and pollen exine formation; it is specifically expressed in the tapetum and miscrospores. The osnp1 mutant plant displays normal vegetative growth but complete male sterility insensitive to environmental conditions. OsNP1 was coupled with an α-amylase gene to devitalize transgenic pollen and the red fluorescence protein (DsRed) gene to mark transgenic seed and transformed into the osnp1 mutant. Self-pollination of the transgenic plant carrying a single hemizygous transgene produced nontransgenic male sterile and transgenic fertile seeds in 1:1 ratio that can be sorted out based on the red fluorescence coded by DsRed Cross-pollination of the fertile transgenic plants to the nontransgenic male sterile plants propagated the male sterile seeds of high purity. The male sterile line was crossed with ∼1,200 individual rice germplasms available. Approximately 85% of the F1s outperformed their parents in per plant yield, and 10% out-yielded the best local cultivars, indicating that the technology is promising in hybrid rice breeding and production.

  14. Sterile insect supply, emergence, and release

    International Nuclear Information System (INIS)

    Dowell, R.V.; Worley, J.; Gomes, P.J.

    2005-01-01

    Insect mass-rearing for a sterile insect technique (SIT) programme is designed to move beyond the large-scale rearing of insects in a laboratory to the industrial production of consistently high-quality insects for sterilization and release. Each facility reflects the unique biology of the insect reared within it, but there are some generalities for all rearing facilities. Rearing insects in self-contained modules offers flexibility, and increased safety from catastrophic occurrences, compared with using a single building which houses all facets of the rearing process. Although mechanizing certain aspects of the rearing steps helps provide a consistently high-quality insect, successful mass-rearing and delivery depends largely upon the human component. Besides production in centralized facilities, insects can be produced from purchased eggs, or nowadays, adult insects are often obtained from specialized satellite emergence/collection facilities. Interest in commercializing insect production and release is increasing. Shipping sterile insects, sometimes over long distances, is now common practice. Procedures for handling and chilling adult insects, and providing food and water prior to release, are continually being improved. Sterile insects are released via static-release receptacles, ground-release systems, or most commonly from the air. The aerial release of chilled sterile insects is the most efficient method of release, especially when aircraft flight paths are guided by a Global Positioning System (GPS) linked to a computer-controlled release mechanism. (author)

  15. Workable male sterility systems for hybrid rice: Genetics, biochemistry, molecular biology, and utilization.

    Science.gov (United States)

    Huang, Jian-Zhong; E, Zhi-Guo; Zhang, Hua-Li; Shu, Qing-Yao

    2014-12-01

    The exploitation of male sterility systems has enabled the commercialization of heterosis in rice, with greatly increased yield and total production of this major staple food crop. Hybrid rice, which was adopted in the 1970s, now covers nearly 13.6 million hectares each year in China alone. Various types of cytoplasmic male sterility (CMS) and environment-conditioned genic male sterility (EGMS) systems have been applied in hybrid rice production. In this paper, recent advances in genetics, biochemistry, and molecular biology are reviewed with an emphasis on major male sterility systems in rice: five CMS systems, i.e., BT-, HL-, WA-, LD- and CW- CMS, and two EGMS systems, i.e., photoperiod- and temperature-sensitive genic male sterility (P/TGMS). The interaction of chimeric mitochondrial genes with nuclear genes causes CMS, which may be restored by restorer of fertility (Rf) genes. The PGMS, on the other hand, is conditioned by a non-coding RNA gene. A survey of the various CMS and EGMS lines used in hybrid rice production over the past three decades shows that the two-line system utilizing EGMS lines is playing a steadily larger role and TGMS lines predominate the current two-line system for hybrid rice production. The findings and experience gained during development and application of, and research on male sterility in rice not only advanced our understanding but also shed light on applications to other crops.

  16. Radiation sterilization

    International Nuclear Information System (INIS)

    Jacobs, G.P.

    1989-01-01

    In view of the application of ionizing radiation to sterilize pharmaceutical products, and the particular advantages of using this mode of sterilization for powders for injection, which cannot be sterilized by more conventional methods, it is important to recognise the possibility of modification of radiation response of bacteria when in close contact with various drug powders. For this study, bacterial spores, which lend themselves to dessication, and which can be dried onto an inert powder matrix, were chosen as the test system. The results of this work indicate that the additives tested have a modest protective effect on the spores. However, when considering a bacterial inactivation for sterilization purposes of between six and ten orders of magnitude, that is, a desired sterility assurance level of an expected maximum probability of a product item being non-sterile of 10 -6 , then the slight protective effect observed in this study approaches insignificance

  17. Thermal sterilization of heat-sensitive products using high-temperature short-time sterilization.

    Science.gov (United States)

    Mann, A; Kiefer, M; Leuenberger, H

    2001-03-01

    High-temperature short-time (HTST) sterilization with a continuous-flow sterilizer, developed for this study, was evaluated. The evaluation was performed with respect to (a) the chemical degradation of two heat-sensitive drugs in HTST range (140-160 degrees C) and (b) the microbiological effect of HTST sterilization. Degradation kinetics of two heat-sensitive drugs showed that a high peak temperature sterilization process resulted in less chemical degradation for the same microbiological effect than a low peak temperature process. Both drugs investigated could be sterilized with acceptable degradation at HTST conditions. For the evaluation of the microbiological effect, Bacillus stearothermophilus ATCC 7953 spores were used as indicator bacteria. Indicator spore kinetics (D(T), z value, k, and E(a)), were determined in the HTST range. A comparison between the Bigelow model (z value concept) and the Arrhenius model, used to describe the temperature coefficient of the microbial inactivation, demonstrated that the Bigelow model is more accurate in prediction of D(T) values in the HTST range. The temperature coefficient decreased with increasing temperature. The influence of Ca(2+) ions and pH value on the heat resistance of the indicator spores, which is known under typical sterilization conditions, did not change under HTST conditions.

  18. Study of fieldbus technology confiability when applied in a Sterilization plant control and safety systems

    International Nuclear Information System (INIS)

    Karma, D.; Sampa, M.H.O.; Rela, P.R.

    2001-01-01

    Several sterilization processes have been used in these years for treatment of countless products. Some processes use high temperatures, thermal shocks and chemical agents. With the discovery of the ionizing radiation and its posterior technological developments turned possible the application of that process, in 1960, also in the sterilization, denominated radiation sterilization. This process became also applied in another areas of health and industrial as food conservation, gemstones enhancement and others. The radiation sterilization requests an effective control and it needs a high level of safety. The commercial use of the computers applied in industrial automation provides and the domain of new technologies in this field provides news applications then new designs now is possible. The Fieldbus technology, a new digital communication protocol, like a Local Area Network, can be an alternative in the cobalt-60 irradiation plant. This paper show preliminary study about confiability in systems using Fieldbus technology. This technology was simulated in sterilization plant control and safety systems and the fail probability was quantified using Fail Tree Analysis Method. Fieldbus technology can be used in sterilization plants because the confiability in this systems is like PLCs and relays systems, was the conclusion

  19. The Plasma Discharge System For Effective Sterilization Of Water And Solid Surfaces

    International Nuclear Information System (INIS)

    Senturk, K.

    2010-01-01

    The different areas such as medicine, surgery, food production need efficient sterilization system since they are directly related to human health. In this work a new plasma system is described in order to present its effectiveness in sterilization. This is a different method from conventional methods such as: chemicals and heat addition, UV irradiation etc. The developed plasma system produces cold plasma working under atmospheric pressure. To generate the plasma both AC and DC high voltage power supplies were used. The developed system is cheap and very effective for sterilization. The light emission for both AC and DC coronas for the plasmas were investigated to understand the nature of generated plasma ionization. Different parameters like temperature, voltage, application time were changed during the plasma application and the optimization for killing the micro-organisms were investigated. To understand the biological effect of plasma on the organisms comparisons were done by using the scanning electron microscope and absorption spectrometer. The plasma was applied on the bacteria like Escherichia coli, Bacillus subtilis, Streptococcus mutans , the yeasts such as Candida albicans, and green algae. The efficiency, the non toxic nature, the affordable price make this plasma discharge method a very efficient one for sterilization.

  20. Transcervical Sterilization: A Comparison of Essure® Permanent Birth Control System and Adiana® Permanent Contraception System

    Science.gov (United States)

    Palmer, Sophia N; Greenberg, James A

    2009-01-01

    Transcervical sterilization has moved female sterilization from a minimally invasive laparoscopic technique, which requires entry into the abdominal cavity, to a less invasive hysteroscopic procedure. Along with the decreased potential for complications, its ease of performance with minimal anesthesia has facilitated a move from the operating room to the office. This review compares the available data on transcervical sterilization procedures to better understand the strengths and weakness of each system. PMID:19609402

  1. Sterilization in Finland: from eugenics to contraception.

    Science.gov (United States)

    Hemminki, E; Rasimus, A; Forssas, E

    1997-12-01

    The purpose of this paper was to describe the transition of sterilization in Finland from an eugenic tool to a contraceptive. Historical data were drawn from earlier reports in Finnish. Numbers of and reasons for sterilizations since 1950 were collected from nationwide sterilization statistics. Prevalence, characteristics of sterilized women, and women's satisfaction with sterilizations were studied from a 1994 nationwide survey (74% response rate). Logistic regression was used for adjustments. In the first half of the 20th century, eugenic ideology had influence in Finland as in other parts of Europe, and the 1935 and 1950 sterilization laws had an eugenic spirit. Regardless of this, the numbers of eugenic sterilizations remained low, and in practice, family planning was the main reason for sterilization. Nonetheless, prior to 1970 not all sterilizations were freely chosen, because sterilizations were sometimes used as a precondition for abortion. Female sterilizations showed remarkable fluctuation over time. Male sterilizations have been rare. The reasons stipulated by the law did not explain the numbers of sterilizations. In a 1994 survey, 9% of Finnish women reported they were using sterilization as their current contraceptive method (n = 189). Compared to women using other contraceptive methods, sterilized women were older, had had more births and pregnancies, and came from lower social classes. Sterilized women were satisfied with their sterilization, but there were women (8.5%) who regretted it. In conclusion, sterilizations have been and are likely to continue to be an important family planning method in Finland. The extreme gender ratio suggests a need for promoting male sterilizations, and women's expressed regrets suggest consideration of a higher age limit.

  2. Continuing to work with a sterile thumb splint: A case report.

    Science.gov (United States)

    Roner, S; Fürnstahl, P; Schweizer, A; Wieser, K

    2018-05-17

    Nonoperative treatment of an injured ulnar collateral ligament of the thumb metacarpophalangeal (MCP) joint (skier's thumb without a Stener lesion) is managed by immobilization. A splint is applied on the radial side with the thumb in slight flexion to immobilize the MCP joint and allow motion in the interphalangeal joint. Thermoplastic splints are mainly used for daily activities with the advantage of custom fabrication for optimal comfort. To immobilize the thumb during surgical procedures performed by an orthopedic surgeon, splints made of sterilizable materials are needed but not yet available to our knowledge. We present the case of a 36-year-old orthopedic surgeon diagnosed with skier's thumb, and the development and application of a reusable, patient-specific (i.e., the orthopedic surgeon) splint to immobilize the thumb MCP joint in a sterile environment so the surgeon could continue working. Copyright © 2018 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  3. Plasma Sterilization: New Epoch in Medical Textiles

    Science.gov (United States)

    Senthilkumar, P.; Arun, N.; Vigneswaran, C.

    2015-04-01

    Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.

  4. Spore-Forming Bacteria that Resist Sterilization

    Science.gov (United States)

    LaDuc, Myron; Venkateswaran, Kasthuri

    2003-01-01

    A report presents a phenotypic and genotypic characterization of a bacterial species that has been found to be of the genus Bacillus and has been tentatively named B. odysseensis because it was isolated from surfaces of the Mars Odyssey spacecraft as part of continuing research on techniques for sterilizing spacecraft to prevent contamination of remote planets by terrestrial species. B. odysseensis is a Gram-positive, facultatively anaerobic, rod-shaped bacterium that forms round spores. The exosporium has been conjectured to play a role in the elevated resistance to sterilization. Research on the exosporium is proposed as a path toward improved means of sterilization, medical treatment, and prevention of biofouling.

  5. Postpartum Sterilization

    Science.gov (United States)

    f AQ FREQUENTLY ASKED QUESTIONS FAQ052 CONTRACEPTION Postpartum Sterilization • What is sterilization? • What is postpartum sterilization? • How is postpartum sterilization performed? • What kind of anesthesia is used for postpartum sterilization? • How ...

  6. EFFECT OF MICROWAVE POWER ON SHAPE OF EPR SPECTRA--APPLICATION TO EXAMINATION OF COMPLEX FREE RADICAL SYSTEM IN THERMALLY STERILIZED ACIDUM BORICUM.

    Science.gov (United States)

    Ramos, Paweł; Pieprzyca, Małgorzata; Pilawa, Barbara

    2016-01-01

    Complex free radical system in thermally sterilized acidum boricum (AB) was studied. Acidum boricum was sterilized at temperatures and times given by pharmaceutical norms: 160 degrees C and 120 min, 170 degrees C and 60 min and 180 degrees C and 30 min. The advanced spectroscopic tests were performed. The EPR spectra of free radicals were measured as the first derivatives with microwaves of 9.3 GHz frequency and magnetic modulation of 100 kHz. The Polish X-band electron paramagnetic resonance spectrometer of Radiopan (Poznań) was used. EPR lines were not observed for the nonheated AB. The broad EPR asymmetric lines were obtained for all the heated AB samples. The influence of microwave power in the range of 2.2-70 mW on the shape of EPR spectra of the heated drug samples was tested. The following asymmetry parameters: A1/A2, A1-A2, B1/B2, and B1-B2, were analyzed. The changes of these parameters with microwave power were observed. The strong dependence of shape and its parameters on microwave power proved the complex character of free radical system in thermally sterilized AB. Changes of microwave power during the detection of EPR spectra indicated complex character of free radicals in AB sterilized in hot air under all the tested conditions. Thermolysis, interactions between free radicals and interactions of free radicals with oxygen may be responsible for the complex free radicals system in thermally treated AB. Usefulness of continuous microwave saturation of EPR lines and shape analysis to examine free radicals in thermally sterilized drugs was confirmed.

  7. Hysteroscopic Sterilization

    Science.gov (United States)

    ... sterilization? Sterilization is a permanent form of birth control. What is tubal sterilization? Sterilization procedures for women are ... is quicker than from other types of sterilization. What are the risks of ... on for birth control. • There is a risk of injury to the ...

  8. Discussion on the compilation of document of iso quality management system for radiation sterilization enterprises

    International Nuclear Information System (INIS)

    Li Chunhong; Ha Yiming; Zhou Hongjie; Feng Zhiguo; Wang Feng

    2006-01-01

    According to the character of cooperation of radiation sterilization, and association with request of ISO9001, ISO13485 and ISO11137, compilation of document in quality manual, procedure document and technological document during certification of ISO quality management system of cooperation of radiation sterilization was discussed. (authors)

  9. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice.

    Science.gov (United States)

    El-Namaky, R; van Oort, P A J

    2017-12-01

    There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two EGMS lines tested here, it was not clear if one or more recessive gene(s) were causing male sterility. This was tested by studying sterility segregation of the F2 populations. Daylength (photoperiod) and minimum temperatures during the period from panicle initiation to flowering had significant effects on male sterility. Results clearly showed that only one recessive gene was involved in causing male sterility. The model was applied to determine the set of sowing dates of two different EGMS lines such that both would flower at the same time the pollen would be completely sterile. In the same time the local popular variety (Sahel 108, the male pollen donor) being sufficiently fertile to produce the hybrid seeds. The model was applied to investigate the viability of the two line breeding system in the same location with climate change (+2oC) and in two other potential locations: in M'Be in Ivory Coast and in the Nile delta in Egypt. Apart from giving new insights in the relation between environment and EGMS, this study shows that these insights can be used to assess safe sowing windows and assess the suitability of sterility and fertility period of different environments for a two line hybrid rice production system.

  10. Construction of a multicontrol sterility system for a maize male-sterile line and hybrid seed production based on the ZmMs7 gene encoding a PHD-finger transcription factor.

    Science.gov (United States)

    Zhang, Danfeng; Wu, Suowei; An, Xueli; Xie, Ke; Dong, Zhenying; Zhou, Yan; Xu, Liwen; Fang, Wen; Liu, Shensi; Liu, Shuangshuang; Zhu, Taotao; Li, Jinping; Rao, Liqun; Zhao, Jiuran; Wan, Xiangyuan

    2018-02-01

    Although hundreds of genetic male sterility (GMS) mutants have been identified in maize, few are commercially used due to a lack of effective methods to produce large quantities of pure male-sterile seeds. Here, we develop a multicontrol sterility (MCS) system based on the maize male sterility 7 (ms7) mutant and its wild-type Zea mays Male sterility 7 (ZmMs7) gene via a transgenic strategy, leading to the utilization of GMS in hybrid seed production. ZmMs7 is isolated by a map-based cloning approach and encodes a PHD-finger transcription factor orthologous to rice PTC1 and Arabidopsis MS1. The MCS transgenic maintainer lines are developed based on the ms7-6007 mutant transformed with MCS constructs containing the (i) ZmMs7 gene to restore fertility, (ii) α-amylase gene ZmAA and/or (iii) DNA adenine methylase gene Dam to devitalize transgenic pollen, (iv) red fluorescence protein gene DsRed2 or mCherry to mark transgenic seeds and (v) herbicide-resistant gene Bar for transgenic seed selection. Self-pollination of the MCS transgenic maintainer line produces transgenic red fluorescent seeds and nontransgenic normal colour seeds at a 1:1 ratio. Among them, all the fluorescent seeds are male fertile, but the seeds with a normal colour are male sterile. Cross-pollination of the transgenic plants to male-sterile plants propagates male-sterile seeds with high purity. Moreover, the transgene transmission rate through pollen of transgenic plants harbouring two pollen-disrupted genes is lower than that containing one pollen-disrupted gene. The MCS system has great potential to enhance the efficiency of maize male-sterile line propagation and commercial hybrid seed production. © 2017 The Authors. Plant Biotechnology Journal published by Society for Experimental Biology and The Association of Applied Biologists and John Wiley & Sons Ltd.

  11. Gamma sterilization of disposable medical products (DMP's)

    International Nuclear Information System (INIS)

    Brinston, R.M.

    1990-01-01

    Ten million cubic meters (361 million cubic feet) of disposable medical products (DMP) and related health care items are estimated to be sterilized in the world. In this paper, current conditions and perspectives of gamma sterilization is discussed in comparison with ethylene oxide gas and electron beams. Of the total sterilization estimates for DMP, 2.8 million cubic meters (99 million cubic feet) are sterilized with gamma radiation, with a market share of 27%. Gamma radiation is becoming increased from both general market growth and the introduction of new products, as well as the conversion of product from ethylene oxide gas to cobalt-60. Regulatory pressures, legal considerations, and increasing publicity surrounding ethylene oxide usage are encouraging manufactures to switch to gamma radiation. Gamma's performance features include: no temperature change during the sterilization, high penetration, even through hermetically sealed packages, no residues, and no post-sterilization treatment or quarantine period. Gamma sterilization is economically beneficial in large volumes of product. Cost saving to the end user of gamma sterilization has meant lower minimum dose levels than 25 KGy. Despite of an increasingly accepted gamma radiation, there are still four factors to be considered, including cobalt-60 availability, price, transportation, and disposal. The price of cobalt-60 is based on neutron cost. In the future, cobalt-60 price is expected to be flat and enables gamma processing to become even more competitive with other sterilization methods. Gamma radiation using cobalt-60 has been proven as a safe, effective, and cost-competitive sterilization method for treating DMP and related health care items. It's wide use and many processing advantages will continue to make it a preferred sterilization method. (N.K.)

  12. Trends in sterilization since the introduction of Essure hysteroscopic sterilization.

    Science.gov (United States)

    Shavell, Valerie I; Abdallah, Mazen E; Shade, George H; Diamond, Michael P; Berman, Jay M

    2009-01-01

    To investigate trends in sterilization in women at the Detroit Medical Center, Michigan (DMC), since the introduction of Essure hysteroscopic sterilization. Retrospective study (Canadian Task Force classification II-2). Outpatient surgery center and university teaching hospitals. Women who underwent interval sterilization procedures at the DMC (Hutzel Women's Hospital, Sinai-Grace Hospital, and the Berry Center) and postpartum sterilization procedures at Hutzel Women's Hospital between January 1, 2002, and December 31, 2007. Permanent sterilization procedures including minilaparotomy tubal ligation, laparoscopic sterilization, Essure hysteroscopic sterilization, and postpartum tubal ligation performed at the time of cesarean section or after vaginal delivery. In all, 5509 permanent sterilization procedures were performed in the 6 years between January 1, 2002, and December 31, 2007, at the DMC facilities analyzed: 2484 interval sterilization procedures at Hutzel Women's Hospital, Sinai-Grace Hospital, and the Berry Center, and 3025 postpartum tubal ligations at Hutzel Women's Hospital. From 2002 through 2007, the decrease in laparoscopic sterilizations from 97.9% to 48.5% of all interval sterilization procedures corresponded significantly with the increase in Essure hysteroscopic sterilizations from 0.0% to 51.3% (p Essure hysteroscopic sterilizations increased significantly from 0.0% to 51.3% of all procedures. Since the approval of Essure hysteroscopic sterilization in November 2002, this minimally invasive method of hysteroscopic sterilization has increased in popularity at the DMC.

  13. Validation of radiation sterilization process

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    The standards for quality management systems recognize that, for certain processes used in manufacturing, the effectiveness of the process cannot be fully verified by subsequent inspection and testing of the product. Sterilization is an example of such a process. For this reason, sterilization processes are validated for use, the performance of sterilization process is monitored routinely and the equipment is maintained according to ISO 13 485. Different aspects of this norm are presented

  14. Sterilization of health care products - Radiation. Part 2: Establishing the sterilization dose

    International Nuclear Information System (INIS)

    2006-01-01

    accordance with ISO 11137-1:2006, Clause 12. Follo wing establishment of the sterilization dose, sterilization dose audits are performed routinely to confirm that the sterilization dose continues to achieve the desired SAL

  15. Genomic networks of hybrid sterility.

    Science.gov (United States)

    Turner, Leslie M; White, Michael A; Tautz, Diethard; Payseur, Bret A

    2014-02-01

    Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities"). The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus) provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL). Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is applicable in a broad

  16. Color stability of shade guides after autoclave sterilization.

    Science.gov (United States)

    Schmeling, Max; Sartori, Neimar; Monteiro, Sylvio; Baratieri, Luiz

    2014-01-01

    This study evaluated the influence of 120 autoclave sterilization cycles on the color stability of two commercial shade guides (Vita Classical and Vita System 3D-Master). The specimens were evaluated by spectrophotometer before and after the sterilization cycles. The color was described using the three-dimensional CIELab system. The statistical analysis was performed in three chromaticity coordinates, before and after sterilization cycles, using the paired samples t test. All specimens became darker after autoclave sterilization cycles. However, specimens of Vita Classical became redder, while those of the Vita System 3D-Master became more yellow. Repeated cycles of autoclave sterilization caused statistically significant changes in the color coordinates of the two shade guides. However, these differences are considered clinically acceptable.

  17. 1 1/2 years of experience with a 10 MeV self-shielded on-line e-beam sterilization system

    International Nuclear Information System (INIS)

    Lambert, Byron; Tang, Fuh-Wei; Riggs, Brian; Allen, Thomas; Williams, C.B.

    2000-01-01

    The Vascular Intervening Group of the Guidant Corporation (Guidant IV) has been operating a self-shielded, 10 MeV 4 kW, electron beam sterilization system since July of 1988. The system was designed, built and installed in a 70 square meter area in an existing Guidant manufacturing facility by Titan Scan Corporation and performance of the system was validated in conformance with 1S0-11137 standards. The goal of this on-site e-beam system was 'just in time' JIT, sterilization, i.e. the ability to manufacture, sterilize and ship, high intrinsic value medical devices in less than 24 hours. The benefits of moving from a long gas sterilization cycle of greater than one week to a JIT process were envisioned to be a) speed to market with innovated new products b) rapid response to customer requirements c) reduced inventory carrying costs and finally manufacturing and quality system efficiency. The ability of Guidant to realize these benefits depended upon the ability of the Guidant VI business units to adapt to the new sterilization modality and functionality and on the overall system reliability. This paper reviews the operating experience to date and the overall system reliability. (author)

  18. Evolvement of transgenic male-sterility and fertility-restoration system in rice for production of hybrid varieties.

    Science.gov (United States)

    Rao, Gundra Sivakrishna; Deveshwar, Priyanka; Sharma, Malini; Kapoor, Sanjay; Rao, Khareedu Venkateswara

    2018-01-01

    We have developed a unique male-sterility and fertility-restoration system in rice by combining Brassica napus cysteine-protease gene (BnCysP1) with anther-specific P12 promoter of rice for facilitating production of hybrid varieties. In diverse crop plants, male-sterility has been exploited as a useful approach for production of hybrid varieties to harness the benefits of hybrid vigour. The promoter region of Os12bglu38 gene of rice has been isolated from the developing panicles and was designated as P12. The promoter was fused with gusA reporter gene and was expressed in Arabidopsis and rice systems. Transgenic plants exhibited GUS activity in tapetal cells and pollen of the developing anthers indicating anther/pollen-specific expression of the promoter. For engineering nuclear male sterility, the coding region of Brassica napus cysteine protease1 (BnCysP1) was isolated from developing seeds and fused to P12 promoter. Transgenic rice plants obtained with P12-BnCysP1 failed to produce functional pollen grains. The F 1 seeds obtained from BnCysP1 male-sterile plants and untransformed controls showed 1:1 (tolerant:sensitive) ratio when germinated on the MS medium supplemented with phosphinothricin (5 mg/l), confirming that the male sterility has been successfully engineered in rice. For male fertility restoration, transgenic rice plants carrying BnCysP1Si silencing system were developed. The pollination of BnCysP1 male-sterile (female-fertile) plants with BnCysP1Si pollen resulted in normal grain filling. The F 1 seeds of BnCysP1 × BnCysP1Si when germinated on the MS basal medium containing PPT (5 mg/l) and hygromycin (70 mg/l) exhibited 1:1 (tolerant:sensitive) ratio and the tolerant plants invariably showed normal grain filling. The overall results clearly suggest that the customized male-sterility & fertility-restoration system can be exploited for quality hybrid seed production in various crops.

  19. Cost-effectiveness analysis comparing the essure tubal sterilization procedure and laparoscopic tubal sterilization.

    Science.gov (United States)

    Thiel, John A; Carson, George D

    2008-07-01

    To analyze the financial implications of establishing a hysteroscopic sterilization program using the Essure micro-insert tubal sterilization system in an ambulatory clinic. A retrospective cohort study (Canadian Task Force classification Type II-2), in an ambulatory women's health clinic in a tertiary hospital, of 108 women undergoing Essure coil insertion between 2005 and 2006, and 104 women undergoing laparoscopic tubal sterilization for permanent sterilization between 2001 and 2004. The Essure procedures used a 4 mm single channel operative hysteroscope and conscious sedation (fentanyl and midazolam); the laparoscopic tubal sterilizations were completed under general anaesthesia with a 7 mm laparoscope and either bipolar cautery or Filshie clips. Costs associated with the procedure, follow-up, and management of any complications (including nursing, hospital charges, equipment, and disposables) were tabulated. The Essure coils were successfully placed on the first attempt in 103 of 108 women (95%). Three patients required a second attempt to complete placement and two patients required laparoscopic tubal sterilization after an unsuccessful Essure. All 104 laparoscopic tubals were completed on the first attempt with no complications reported. The total cost for the 108 Essure procedures, including follow-up evaluation, was $138,996 or $1287 per case. The total cost associated with the 104 laparoscopic tubal sterilization procedures was $148,227 or $1398 per case. The incremental cost-effectiveness ratio was $111. The Essure procedure in an ambulatory setting resulted in a statistically significant cost saving of $111 per sterilization procedure. Carrying out the Essure procedure in an ambulatory setting frees space in the operating room for other types of cases, improving access to care for more patients.

  20. Genomic networks of hybrid sterility.

    Directory of Open Access Journals (Sweden)

    Leslie M Turner

    2014-02-01

    Full Text Available Hybrid dysfunction, a common feature of reproductive barriers between species, is often caused by negative epistasis between loci ("Dobzhansky-Muller incompatibilities". The nature and complexity of hybrid incompatibilities remain poorly understood because identifying interacting loci that affect complex phenotypes is difficult. With subspecies in the early stages of speciation, an array of genetic tools, and detailed knowledge of reproductive biology, house mice (Mus musculus provide a model system for dissecting hybrid incompatibilities. Male hybrids between M. musculus subspecies often show reduced fertility. Previous studies identified loci and several X chromosome-autosome interactions that contribute to sterility. To characterize the genetic basis of hybrid sterility in detail, we used a systems genetics approach, integrating mapping of gene expression traits with sterility phenotypes and QTL. We measured genome-wide testis expression in 305 male F2s from a cross between wild-derived inbred strains of M. musculus musculus and M. m. domesticus. We identified several thousand cis- and trans-acting QTL contributing to expression variation (eQTL. Many trans eQTL cluster into eleven 'hotspots,' seven of which co-localize with QTL for sterility phenotypes identified in the cross. The number and clustering of trans eQTL-but not cis eQTL-were substantially lower when mapping was restricted to a 'fertile' subset of mice, providing evidence that trans eQTL hotspots are related to sterility. Functional annotation of transcripts with eQTL provides insights into the biological processes disrupted by sterility loci and guides prioritization of candidate genes. Using a conditional mapping approach, we identified eQTL dependent on interactions between loci, revealing a complex system of epistasis. Our results illuminate established patterns, including the role of the X chromosome in hybrid sterility. The integrated mapping approach we employed is

  1. Forced sterilization of women as discrimination.

    Science.gov (United States)

    Patel, Priti

    2017-01-01

    There has been a long history of subjecting marginalized women to forced and coerced sterilization. In recent years, the practice has been documented in countries in North and South America, Europe, Asia, and Africa. It has targeted women who are ethnic and racial minorities, women with disabilities, women living with HIV, and poor women. A handful of courts have issued decisions on the recent forced sterilization of marginalized women finding that such actions violate the women's rights. However, they have all failed to address the women's claims of discrimination. The failure to acknowledge that forced sterilization is at its core a violation of the prohibition of discrimination undermines efforts to eradicate the practice. It further fails to recognize that coerced and forced sterilization fundamentally seeks to deny women deemed as "unworthy" the ability to procreate. Four key principles outlined in the human rights in patient care framework highlight the importance of a finding that the prohibition of discrimination was violated in cases of forced sterilization: the need to highlight the vulnerability of marginalized populations to discrimination in health care settings; the importance of the rights of medical providers; the role of the state in addressing systemic human rights violations in health care settings; and the application of human rights to patient care. Based on these principles, it is clear that finding a violation of the prohibition of discrimination in forced sterilization cases is critical in addressing the systemic nature of the practice, acknowledging the marginalization of specific groups and effectively ending forced sterilization through addressing the underlying purpose of the practice. If litigators, non-governmental organizations and judicial officers are mindful of these principles when dealing with cases of forced sterilization, it is likely that they will be better able to eradicate forced sterilization.

  2. Effect of repeated sterilization by different methods on strength of carbon fiber rods used in external fixator systems.

    Science.gov (United States)

    Unal, Omer Kays; Poyanli, Oguz Sukru; Unal, Ulku Sur; Mutlu, Hasan Huseyin; Ozkut, Afsar Timucin; Esenkaya, Irfan

    2018-05-16

    We set out to reveal the effects of repeated sterilization, using different methods, on the carbon fiber rods of external fixator systems. We used a randomized set of forty-four unused, unsterilized, and identical carbon fiber rods (11 × 200 mm), randomly assigned to two groups: unsterilized (US) (4 rods) and sterilized (40 rods). The sterilized rods were divided into two groups, those sterilized in an autoclave (AC) and by hydrogen peroxide (HP). These were further divided into five subgroups based on the number of sterilization repetition to which the fibers were subjected (25-50-75-100-200). A bending test was conducted to measure the maximum bending force (MBF), maximum deflection (MD), flexural strength (FS), maximum bending moment (MBM) and bending rigidity (BR). We also measured the surface roughness of the rods. An increase in the number of sterilization repetition led to a decrease in MBF, MBM, FS, BR, but increased MD and surface roughness (p < 0.01). The effect of the number of sterilization repetition was more prominent in the HP group. This study revealed that the sterilization method and number of sterilization repetition influence the strength of the carbon fiber rods. Increasing the number of sterilization repetition degrades the strength and roughness of the rods.

  3. Cosmological lepton asymmetry, primordial nucleosynthesis and sterile neutrinos

    Science.gov (United States)

    Abazajian, Kevork; Bell, Nicole F.; Fuller, George M.; Wong, Yvonne Y. Y.

    2005-09-01

    We study post weak decoupling coherent active-sterile and active-active matter-enhanced neutrino flavor transformation in the early Universe. We show that flavor conversion efficiency at Mikheyev-Smirnov-Wolfenstein resonances is likely to be high (adiabatic evolution) for relevant neutrino parameters and energies. However, we point out that these resonances cannot sweep smoothly and continuously with the expansion of the Universe. We show how neutrino flavor conversion in this way can leave both the active and sterile neutrinos with nonthermal energy spectra, and how, in turn, these distorted energy spectra can affect the neutron-to-proton ratio, primordial nucleosynthesis, and cosmological mass/closure constraints on sterile neutrinos. We demonstrate that the existence of a light sterile neutrino which mixes with active neutrinos can change fundamentally the relationship between the cosmological lepton numbers and the primordial nucleosynthesis He4 yield.

  4. Standardized Method for High-throughput Sterilization of Arabidopsis Seeds.

    Science.gov (United States)

    Lindsey, Benson E; Rivero, Luz; Calhoun, Chistopher S; Grotewold, Erich; Brkljacic, Jelena

    2017-10-17

    Arabidopsis thaliana (Arabidopsis) seedlings often need to be grown on sterile media. This requires prior seed sterilization to prevent the growth of microbial contaminants present on the seed surface. Currently, Arabidopsis seeds are sterilized using two distinct sterilization techniques in conditions that differ slightly between labs and have not been standardized, often resulting in only partially effective sterilization or in excessive seed mortality. Most of these methods are also not easily scalable to a large number of seed lines of diverse genotypes. As technologies for high-throughput analysis of Arabidopsis continue to proliferate, standardized techniques for sterilizing large numbers of seeds of different genotypes are becoming essential for conducting these types of experiments. The response of a number of Arabidopsis lines to two different sterilization techniques was evaluated based on seed germination rate and the level of seed contamination with microbes and other pathogens. The treatments included different concentrations of sterilizing agents and times of exposure, combined to determine optimal conditions for Arabidopsis seed sterilization. Optimized protocols have been developed for two different sterilization methods: bleach (liquid-phase) and chlorine (Cl2) gas (vapor-phase), both resulting in high seed germination rates and minimal microbial contamination. The utility of these protocols was illustrated through the testing of both wild type and mutant seeds with a range of germination potentials. Our results show that seeds can be effectively sterilized using either method without excessive seed mortality, although detrimental effects of sterilization were observed for seeds with lower than optimal germination potential. In addition, an equation was developed to enable researchers to apply the standardized chlorine gas sterilization conditions to airtight containers of different sizes. The protocols described here allow easy, efficient, and

  5. Modernization of safety system for the radiation facility for industrial sterilization

    International Nuclear Information System (INIS)

    Drndarevic, V.; Djuric, D.; Koturovic, A.; Arandjelovic, M.; Mikic, R.

    1995-01-01

    Modernization of the existing safety system of the radiation facility for industrial sterilization at the Vinca Institute of nuclear science is done. In order to improve radiation safety of the facility, the latest recommendations and requirements of IAEA have been implemented. Concept and design of the modernized system are presented. The new elements of the safety system are described and the improvements achieved by means of this modernization are pointed out. (author)

  6. The Sterile Insect Technique:Current and Future Prospects

    International Nuclear Information System (INIS)

    ALRubeai, H.F.

    2004-01-01

    Considering the importance of the Key insect pests and their potential for economic and environmental impact, such species are the targets for area-wide approaches including in some cases the use of SIT. At the heart of the SIT is genetic sterility that is introduced into the target population by releasing large numbers of sterile insects . The development of an SIT package for a Key pest, involving mass rearing and aerial dispersion, as well as field monitoring and a suppression system. Losses caused by insect pests throughout the developing world will continue to be unacceptably high in the foreseeable future. Therefore, the economic feasibility of non-chemical pest control tools, including biologically -based methods such as SIT, will become increasingly apparent . This study include an overview of the basic scientific principles of SIT , is successful applications and related mass rearing and irradiation facilities over the world. (author)

  7. Cryoradiation sterilization - contemporary state and outlook

    International Nuclear Information System (INIS)

    Talrose, V.L.

    1995-01-01

    The new approach of radiation sterilization -cryoradiosterilization with programmed freezing - was developed for pharmaceutical solutions. Both scientific and technical problems are solved, the results are discussed. Programmed freezing of vials with the drug's solutions provides the high stability of soluted components with biological activity at sterilizing irradiation without significant change of sterilization doses. Physical, chemical, biological and pharmacological properties of a lot of drug solutions for injection satisfy official requirements after cryoradiation sterilization treatment. This method seems to be especially important for the protein systems which could be infected by dangerous viruses (VIH, hepatitis B): blood plasma, diagnostic sera, protein preparations manufactured from donor's blood, etc. (Author)

  8. Adaptation of cell renewal systems under continuous irradiation

    International Nuclear Information System (INIS)

    Fabrikant, J.I.

    1987-01-01

    There are adaptive changes in the proliferative characteristics of renewal tissues under the stress of continuous low-dose-rate irradiation which indicate that cell and tissue kinetics will have a considerable effect on the radiation response. Factors that determine the adaptation response involve cellular radiosensitivity, i.e. cell cycle effects, which determine the rate of cell sterilization and death, and compensatory cell proliferation and the capacity for regeneration, i.e. changes in the patterns of cell population kinetics, which determine the rate of cell birth. In rapidly dividing cell renewal systems, there is an effective elimination of damaged cells, with almost complete repair of cellular nonlethal damage. In slowly dividing renewal tissues, there is some repair or elimination of cellular radiation damage and the pattern of cell proliferation during regeneration is relatively little disturbed by prior continuous irradiation. Experimental data on intestinal epithelium, immunohematopoietic tissues, seminiferous epithelium and regenerating liver are presented. Discussion includes differences in adaptation to continuous low-dose-rate irradiation involving intracellular and extracellular control mechanisms which regulate cellular proliferation and differentiation and, thereby, control cell population levels and physiological function. 29 references

  9. Male sterility in plants. Induction, isolation and utilization

    International Nuclear Information System (INIS)

    Driscoll, C.J.; Barlow, K.K.

    1976-01-01

    Both induced and spontaneously arising male sterility mutants exist in a number of important plant species. These mutants are somewhat unique in that they effect procedures for breeding improved varieties. They allow for the possibility of easily obtaining large numbers of hybrids, population breeding systems and the production of hybrid varieties. These mutants are normally classified as cytoplasmic mutants or chromosomal mutants, the latter also being referred to as nuclear or genic mutants. Specific examples of these types of sterility are examined in relation to the breeding system of the species and their potential use for varietal development. Male sterility in diploid and polyploid species is compared, with reference to gene duplication in polyploids. The mechanism of male sterility is examined in the various species at the anatomical and biochemical levels. Methods of isolating male sterility mutants are compared and a specific example is outlined for hexaploid wheat. Future use of male sterility mutants for improving varieties of various crops is examined. (author)

  10. Cleaning and sterilization in biotechnological clean system. Biotechnological clean system no senjo sakkin

    Energy Technology Data Exchange (ETDEWEB)

    Inoue, M.

    1994-02-20

    Despite their usefulness for mankind, many of microorganisms are generally emphasized of the aspect of their harmfulness as decomposable and pathogenic microorganisms, apt to implant people with wrong preconception. Moreover, the food industries have a habitual practice that they leave unexpectedly unclean conditions unattended. This paper indicates such actual circumstances by quoting various examples, and introduces characteristics and test results on commercially available chemicals having excellent cleansing and sterilizing effects. High-pressure and high-temperature sterilization processes fit the purpose of preservation, but secondary contamination may occur in subsequent processing, for example, from the ceiling and walls of a work room, or operators' fingers. Problems exist there that should be considered in biotechnological clean systems. Technologies have been advanced that mix a small amount of chemicals into plastic sheets, wall materials, and floor materials so that their surfaces are kept away from growth of microorganisms for extended periods of time. About 300 kinds of chemicals have been developed, and are available commercially. 3 refs., 8 figs.

  11. End-preparation assessments and tests for compounded sterile preparations.

    Science.gov (United States)

    McElhiney, Linda F

    2013-01-01

    Outsourcing has become a necessity to obtain sterile products that are currently on backorder. Because of the expense of outsourcing sterile compounding, pharmacy leadership in health systems are now considering the option of insourcing and batch preparing compounded sterile preparations, which can be a viable option for a health system. It can significantly decrease drug-spending costs, and the pharmacy has a complete record of the compounding process. The key to preparing high-quality, safe, sterile preparations and meeting United States Pharmacopeia standards is end-preparation assessments and tests.

  12. Sterile neutrino

    International Nuclear Information System (INIS)

    Anon.

    2007-01-01

    Paper deals with the information on the occurrence of the fields of the sterile neutrinos (the righthanded ones) mixed with the normal neutrinos (the lefthanded ones). Both the Max Plank Radioastronomy Institute and the Los Angeles University assumes that the occurrence of the keV mass sterile neutrinos may explain the dark matter nature, the fast rotation of the observed pulsars and the reionization processes. The issues associated with the possibility to record the sterile neutrinos were analyzed in the course of the Sterile Neutrinos in Astrophysics and Cosmology Workshop (Crans Montana, March 2006 [ru

  13. Gamma-sterilization

    International Nuclear Information System (INIS)

    Lindgren, E.

    1974-01-01

    The author makes a survey of his experience in sterilization and sterility control of medical products. At present three different methods are used, steamsterilization, gassterilizing and gammasterilizing. The investments and costs for gamma radiation is presented and a comparison of the costs for gamma- and gassterilization including sterility control is made. (M.S.)

  14. Auditing radiation sterilization facilities

    Science.gov (United States)

    Beck, Jeffrey A.

    The diversity of radiation sterilization systems available today places renewed emphasis on the need for thorough Quality Assurance audits of these facilities. Evaluating compliance with Good Manufacturing Practices is an obvious requirement, but an effective audit must also evaluate installation and performance qualification programs (validation_, and process control and monitoring procedures in detail. The present paper describes general standards that radiation sterilization operations should meet in each of these key areas, and provides basic guidance for conducting QA audits of these facilities.

  15. ISO radiation sterilization standards

    International Nuclear Information System (INIS)

    Lambert, Byron J.; Hansen, Joyce M.

    1998-01-01

    This presentation provides an overview of the current status of the ISO radiation sterilization standards. The ISO standards are voluntary standards which detail both the validation and routine control of the sterilization process. ISO 11137 was approved in 1994 and published in 1995. When reviewing the standard you will note that less than 20% of the standard is devoted to requirements and the remainder is guidance on how to comply with the requirements. Future standards developments in radiation sterilization are being focused on providing additional guidance. The guidance that is currently provided in informative annexes of ISO 11137 includes: device/packaging materials, dose setting methods, and dosimeters and dose measurement, currently, there are four Technical Reports being developed to provide additional guidance: 1. AAMI Draft TIR, 'Radiation Sterilization Material Qualification' 2. ISO TR 13409-1996, 'Sterilization of health care products - Radiation sterilization - Substantiation of 25 kGy as a sterilization dose for small or infrequent production batches' 3. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization Selection of a sterilization dose for a single production batch' 4. ISO Draft TR, 'Sterilization of health care products - Radiation sterilization-Product Families, Plans for Sampling and Frequency of Dose Audits'

  16. Male sterility in chestnuts

    International Nuclear Information System (INIS)

    Omura, Mitsuo; Akihama, Tomoya

    1982-01-01

    A tentative plan was proposed for chestnuts based on their pollination system, male sterility and restoration. The studies on the male sterility of 1,063 cultivars and clones suggested that there were three types of male sterility. The first type (S-1) was characterized by antherless florets. In the second type (S-2), the catkins fell before anthesis, and the third type (S-3) appeared to develop normally in gross floral morphology, but the pollen grains were abnormal in shape and did not have germinating power. In an interspecific hybrid clone CS which belonged to S-1, fertility was restored in an open pollinated progeny. The use of CS and CSO-3 with its restored fertility, permitted the planning of breeding the chestnut hybrid cultivars propagated by seeds. The inbred clones with either male sterility or restorer genes are first bred mainly by back crossing with parents with favorable pollen. The clones are selected individually for early bearing, wasp and disease resistance, and restoration. Then, the hybrid seedling lines between male sterile and restorer inbreds are evaluated for homogenity in nut characters and tree habits. Next, the hybrid seedling lines selected will be examined for crop yield, vigor and cross compatibility. The superior seedling lines are finally selected, and the parental inbreds are grafted to be propagated for seed production orchards. (Kaihara, S.)

  17. A novel male sterility-fertility restoration system in plants for hybrid seed production.

    Science.gov (United States)

    Singh, Surendra Pratap; Singh, Sudhir P; Pandey, Tripti; Singh, Ram Rakshpal; Sawant, Samir V

    2015-06-15

    Hybrid seeds are used for stimulated crop production, as they harness heterosis. The achievement of complete male-sterility in the female-parent and the restored-fertility in F1-hybrids are the major bottlenecks in the commercial hybrid seed production. Here, we report a male sterility-fertility restoration system by engineering the in most nutritive anther wall layer tapetum of female and male parents. In the female parent, high-level, and stringent expression of Arabidopsis autophagy-related gene BECLIN1 was achieved in the tapetum, which altered the tapetal degeneration program, leading to male sterility. This works on our previously demonstrated expression cassette based on functional complementation of TATA-box mutant (TGTA) promoter and TATA-binding protein mutant3 (TBPm3), with modification by conjugating Long Hypocotyle in Far-Red1 fragment (HFR1(NT131)) with TBPm3 (HFR1(NT131)-TBPm3) to exercise regulatory control over it. In the male parent, tapetum-specific Constitutive photo-morphogenesis1 (COP1) was expressed. The F1 obtained by crossing these engineered parents showed decreased BECLIN1 expression, which was further completely abolished when COP1-mutant (COP1(L105A)) was used as a male parent, leading to normal tapetal development and restored fertility. The system works on COP1-HFR1 interaction and COP1-mediated degradation of TBPm3 pool (HFR1(NT131)-TBPm3). The system can be deployed for hybrid seed production in agricultural crops.

  18. Quality management systems for fruit fly (Diptera: Tephritidae) sterile insect technique

    International Nuclear Information System (INIS)

    Caceres, C.; Robinson, A.; McInnis, D.; Shelly, T.; Jang, E.; Hendrichs, J.

    2007-01-01

    The papers presented in this issue are focused on developing and validating procedures to improve the overall quality of sterile fruit flies for use in area-wide integrated pest management (AW-IPM) programs with a sterile insect technique (SIT) component. The group was coordinated and partially funded by the Joint FAO/IAEA Programme of Nuclear Techniques in Food and Agriculture, International Atomic Energy Agency, Vienna, Austria, under a five-year Coordinated Research Project (CRP) on 'Quality Assurance in Mass-Reared and Released Fruit Flies for Use in SIT Programmes'. Participants in the CRP from 16 countries came from both basic and applied fields of expertise to ensure that appropriate and relevant procedures were developed. A variety of studies was undertaken to develop protocols to assess strain compatibility and to improve colonization procedures and strain management. Specific studies addressed issues related to insect nutrition, irradiation protocols, field dispersal and survival, field cage behavior assessments, and enhancement of mating competitiveness. The main objective was to increase the efficiency of operational fruit fly programs using sterile insects and to reduce their cost. Many of the protocols developed or improved during the CRP will be incorporated into the international quality control manual for sterile tephritid fruit flies, standardizing key components of the production, sterilization, shipment, handling, and release of sterile insects. (author) [es

  19. Economical aspects of radiation sterilization with electron beam

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.

    1998-01-01

    Radiation sterilization has been introduced in Poland in the early seventies. Since then continuous progress is observed in quantity of sterilized products. The commercial irradiation facility was built in 1993 to fulfill growing demands for radiation service. The real costs of running this plant were shown. The share of the cost of investment and the cost of maintenance and spare parts in accelerator exploitation, as well as the cost of one hour accelerator exploitation against time of one year accelerator exploitation were taken into account

  20. Food packaging and radiation sterilization

    International Nuclear Information System (INIS)

    Kawamura, Yoko

    1998-01-01

    Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The γ ray and an electron beam are commonly used in radiation sterilization. The γ ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing relatively thin materials and surface sterilization due to the weak transmission. A typical sterilization dose is approximately 10-30 kGy. Direct effects impacting packaging materials, particularly plastics, include scission of polymer links, cross-linkage between polymers, and generating radiolysis products such as hydrogen, methane, aliphatic hydrocarbons, etc. Furthermore, under the existence of oxygen, the oxygen radicals generated by the radiation will oxidize and peroxidize polymer chains and will generate alcohol and carbonyl groups, which shear polymer links, and generate oxygen containing low molecular compounds. As a result, degradation of physical strength such as elongation and seal strength, generating foreign odor, and an increase in global migration values shown in an elution test are sometimes evident. The food packages have different shapes, materials, additives, number of microorganisms and purpose. Therefor the effects of radiation, the optimum dose and so on must be investigated on the individual package. (J.P.N.)

  1. Status of radiation sterilization of healthcare products in China

    International Nuclear Information System (INIS)

    Zhu Nankang; Wang Chunlei; Teng Weifang

    2004-01-01

    This paper describes the status of 60 Co radiation facilities both in service and under construction in China and examines the future market for radiation sterilization of healthcare products. Policies for developing the industry of radiation sterilization are also put forward; these include implementation of appropriate quality systems, scale-up and merging of existing radiation facilities, development of electron beam radiation for sterilization purposes and increasing awareness of the technology of radiation sterilization

  2. Radio-sterilization and processing of frozen human skin

    International Nuclear Information System (INIS)

    Zarate S, Herman; Aguirre H, Paulina; Silva R, Samy; Hitschfeld G, Mario

    2006-01-01

    The Laboratory of Radio-sterilized Biological Tissues Processing (LPTR) belonging to the Chilean Commission of Nuclear Energy and the International Atomic Energy Agency have played a paramount role in our country, concerning the biological tissue processing, which can be radio-sterilized as human skin, pig skin, amniotic membrane, human bone and bovine bone. The frozen radio.-sterilized human skin processing began in 2001, by means of putting into practice the knowledge acquired in training courses through the IAEA and the experience transferred by experts who visited our laboratory. The human skin processing of dead donor can be divided into 6 stages: a) Profuse washing with physiological sterilized serum in to remove the microorganisms, chemical and pharmacological compounds; b) immersion in glycerol solution at 10% to better keep the stored tissues; c) packing, to avoid post manipulation of the sterilized tissue; d) microbiological controls which allow and guarantee a sterility assurance level of 10 6 ; e) radio-sterilization, technique that consists of exposing the grafts to electromagnetic gamma waves which eliminate the microorganisms of the tissue, f) and finally, dispatching and liberation of the frozen sterilized human skin for its clinical use in different centers that take care of burned people. The LPTR receives feedback from surgeons who have used these tissues in order to improve the processing stages based in an integral quality system ISO 9001.2000. The State Health System in our country counts on limited and scarce resources to implement synthetic substitutes that is why It is considered necessary to spread the use of these noble tissues which have sterility assurance and they are processed at low price

  3. Radiation sterilization facility for melon fly

    International Nuclear Information System (INIS)

    Danno, A.

    1985-01-01

    The melon fly (Dacus cucurbitae Coquillett) has been observed in Amami Island since l975. Kagoshima Prefecture has had a melon fly eradication project underway since 1979. A mass-fearing facility and a radiation sterilization facility were constructed in Naze in March of l98l. In the early stages of the project, sterile insects were produced at the rate of 4 x l0/sup 6/ pupae/week. In the later stages, the activity of the project was enlarged by tenfold. The conditions for design of the radiation sterilization facility, which has been developed with a central control system for automated irradiation, are examined from an engineering standpoint

  4. Practices of radiation sterilization of medical products and pharmaceutical preparations: egyptian experience

    International Nuclear Information System (INIS)

    Roushdy, H.M.

    1992-01-01

    Radiation sterilization involves the application of sufficient ionizing energy furnished by either x-rays, gamma-rays or accelerated electron beams, to render an article free of viable micro-organisms. The method offers a number of advantages which makes it an attractive choice in a number of situations: It is a suitable means of sterilizing many many materials.. Radiation causes no significant temperature rise, thus permits sterilization of heat-sensitive drugs and low melting-point plastics. It is certainly the best, and often the only method of sterilizing biological tissues and preparations of biological origin. due to its high penetrating ability, gamma-radiation reaches all parts of the object to be sterilized. The radiation sterilized products are not subjected to touching or exposure to the outside environment except by the and users. The chemical reactivity of radiation is relatively low as compared with the highly reactive gases. Radiation can be easily adapted for continuous processing as compared with batch operations currently in use with gas sterilization. The radiation process is the most reliable of all competing sterilization methods due to the obsolete certainty that the radiation source emits radiation of known energy and power

  5. Practices of radiation sterilization of medical products and pharmaceutical preparations: egyptian experience

    Energy Technology Data Exchange (ETDEWEB)

    Roushdy, H M

    1993-12-31

    Radiation sterilization involves the application of sufficient ionizing energy furnished by either x-rays, gamma-rays or accelerated electron beams, to render an article free of viable micro-organisms. The method offers a number of advantages which makes it an attractive choice in a number of situations: It is a suitable means of sterilizing many many materials.. Radiation causes no significant temperature rise, thus permits sterilization of heat-sensitive drugs and low melting-point plastics. It is certainly the best, and often the only method of sterilizing biological tissues and preparations of biological origin. due to its high penetrating ability, gamma-radiation reaches all parts of the object to be sterilized. The radiation sterilized products are not subjected to touching or exposure to the outside environment except by the and users. The chemical reactivity of radiation is relatively low as compared with the highly reactive gases. Radiation can be easily adapted for continuous processing as compared with batch operations currently in use with gas sterilization. The radiation process is the most reliable of all competing sterilization methods due to the obsolete certainty that the radiation source emits radiation of known energy and power.

  6. Radiation sterilization of livestock feeds

    International Nuclear Information System (INIS)

    Kawashima, Koji

    1984-01-01

    The radiation sterilization of livestock feeds is not much used presently because the process is not known well, and the cost is relatively high. However, its effect of sterilization is absolute, the radiation-sterilized feeds are safe in both nutrition and toxicity, and do not affect the appetite of livestocks, and the radiation energy required is small. In the future, as in the sterilization of medical supplies, feed radiation sterilization plants should be established, to stabilize livestock industry and to contribute to the health control of experimental animals. The following matters are described: radiation, comparison between radiation sterilization and other sterilization methods, the practice of feed radiation sterilization, the adverse effects of radiation sterilization, economic aspect, and the situation of feed radiation sterilization in various countries. (Mori, K.)

  7. Inherited sterility in insects

    International Nuclear Information System (INIS)

    Carpenter, J.E.; Marec, F.; Bloem, S.

    2005-01-01

    The unique genetic phenomena responsible for inherited sterility (IS) in Lepidoptera and some other arthropods, as compared with full sterility, provide advantages for pest control. Lepidopteran females are usually more sensitive to radiation than males of the same species. This allows the radiation dose to be adjusted to suit programme requirements. When partially sterile males mate with wild females, the radiation-induced deleterious effects are inherited by the F 1 generation. As a result, egg hatch is reduced and the resulting offspring are both highly sterile and predominately male. Compared with the high radiation required to achieve full sterility in Lepidoptera, the lower dose of radiation used to induce F 1 sterility increases the quality and competitiveness of the released insects as measured by improved dispersal after release, increased mating ability, and superior sperm competition. F 1 sterile progeny produced in the field enhance the efficacy of released partially sterile males, and improve compatibility with other pest control strategies. In addition, F 1 sterile progeny can be used to increase the production of natural enemies, and to study the potential host and geographical ranges of exotic lepidopteran pests. (author)

  8. A Study on the Application of UV Sterilization Method in HVAC System

    International Nuclear Information System (INIS)

    Cho, S. W.; Park, J. S.; Seo, I. W.; Lim, K. R.; An, W. S.; Oh, S. H.; Lee, K. W.; Kim, J. G.; Kwon, S. J.

    2005-04-01

    The objective of this report is to study on the application of UV sterilization method on HVAC system in building. One type of commercial UV lamp was utilized during this research. It was 1,050 mm length, 24.5 mm diameter, 65 w lamp output, single ended lamp intended for insertion into al frame from inside. Twenty six lamps were mounted and operated in cross flow. They were allowed to operate for at least 30 minutes prior to beginning each test. The test rig was operated at 2.5 m/s and 20 .deg. C, and the relatively humidity 21.6 %RH. The effect of UV sterilization are investigated that as the general virus about 94 %, the mold microbe about 64 % and the bacillus about 86 %, respectively. Following this report will be used important data for the design and manufacture of the UV

  9. A Study on the Application of UV Sterilization Method in HVAC System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, S. W.; Park, J. S.; Seo, I. W.; Lim, K. R.; An, W. S.; Oh, S. H.; Lee, K. W.; Kim, J. G.; Kwon, S. J

    2005-04-15

    The objective of this report is to study on the application of UV sterilization method on HVAC system in building. One type of commercial UV lamp was utilized during this research. It was 1,050 mm length, 24.5 mm diameter, 65 w lamp output, single ended lamp intended for insertion into al frame from inside. Twenty six lamps were mounted and operated in cross flow. They were allowed to operate for at least 30 minutes prior to beginning each test. The test rig was operated at 2.5 m/s and 20 .deg. C, and the relatively humidity 21.6 %RH. The effect of UV sterilization are investigated that as the general virus about 94 %, the mold microbe about 64 % and the bacillus about 86 %, respectively. Following this report will be used important data for the design and manufacture of the UV.

  10. Exploiting novel sterilization techniques for porous polyurethane scaffolds.

    Science.gov (United States)

    Bertoldi, Serena; Farè, Silvia; Haugen, Håvard Jostein; Tanzi, Maria Cristina

    2015-05-01

    Porous polyurethane (PU) structures raise increasing interest as scaffolds in tissue engineering applications. Understanding the effects of sterilization on their properties is mandatory to assess their potential use in the clinical practice. The aim of this work is the evaluation of the effects of two innovative sterilization techniques (i.e. plasma, Sterrad(®) system, and ozone) on the morphological, chemico-physical and mechanical properties of a PU foam synthesized by gas foaming, using water as expanding agent. In addition, possible toxic effects of the sterilization were evaluated by in vitro cytotoxicity tests. Plasma sterilization did not affect the morphological and mechanical properties of the PU foam, but caused at some extent degradative phenomena, as detected by infrared spectroscopy. Ozone sterilization had a major effect on foam morphology, causing the formation of new small pores, and stronger degradation and oxidation on the structure of the material. These modifications affected the mechanical properties of the sterilized PU foam too. Even though, no cytotoxic effects were observed after both plasma and ozone sterilization, as confirmed by the good values of cell viability assessed by Alamar Blue assay. The results here obtained can help in understanding the effects of sterilization procedures on porous polymeric scaffolds, and how the scaffold morphology, in particular porosity, can influence the effects of sterilization, and viceversa.

  11. Plant's sterilization rule for fertile women cited.

    Science.gov (United States)

    1979-01-01

    The American Cyanamid Corporation has been cited by the Occupational Safety and Health Administration (OSHA) for violating federal law by requiring female employees of childbearing age to be sterilized in order to continue working in areas of the plant where they would be exposed to high levels of airborne lead. High levels of airborne lead can cause damage to workers' reproductive systems and be responsible for birth defects in fetuses. The OSHA charged that American Cyanamid's policy constituted a "willful violation" of the 1970 Occupational Safety and Health Act. The Act requires employers to provide employment that is free from recognized hazards likely to cause death or physical harm. According to OSHA, the Act does not allow an employer to eliminate the hazard by compelling employees to choose between losing their jobs and undergoing sterilization. The reproductive health of workers is considered a valid part of OSHA's regulatory concern. The citation, which carries a $10,000 fine, grew out of a complaint that was filed by the Oil, Chemical and Atomic Workers Union on behalf of 5 female workers working in the lead pigment division of the company's Willow Island, West Virginia plant. The 5 employees alleged that they had themselves sterilized to avoid being transferred to other and possibly lower paying janitorial jobs or losing thier jobs completely. The company is appealing the citation. The union has also filed a complaint with the Equal Employment Opportunity Commission charging American Cyanamid with sex discrimination, since only the women workers are at risk of being transferred to lower paying jobs.

  12. Gene, protein and network of male sterility in rice

    Directory of Open Access Journals (Sweden)

    Wang eKun

    2013-04-01

    Full Text Available Rice is one of the most important model crop plants whose heterosis has been well exploited in commercial hybrid seed production via a variety of types of male sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and proteins related to cytoplasmic male sterility, photoperiod sensitive male sterility, self-incompatibility and other types of microspores deterioration have been characterized through genetics or proteomics. Especially the latter, offers us a powerful and high throughput approach to discern the novel proteins involving in male-sterile pathways which may help us to breed artificial male-sterile system. This represents an alternative tool to meet the critical challenge of further development of hybrid rice. In this paper, we reviewed the recent developments in our understanding of male sterility in rice hybrid production across gene, protein and integrated network levels, and also, present a perspective on the engineering of male sterile lines for hybrid rice production.

  13. Lack of insurance and parity influence choice between long-acting reversible contraception and sterilization in women postpregnancy.

    Science.gov (United States)

    Baldwin, Maureen K; Rodriguez, Maria I; Edelman, Alison B

    2012-07-01

    Disparities in postpregnancy contraception utilization exist, with low-income women disproportionately undergoing sterilization. We assessed the impact of increased intrauterine device (IUD) availability on rates of female sterilization. Hospital billing records were used to identify women with an IUD placement or sterilization within 1 year of a pregnancy at a university hospital between Oct 2005 and Jun 2007. Demographic data were compared between women receiving either an IUD or sterilization. There were 365 sterilizations and 223 IUD placements during the study period. IUD placements doubled over the study period from 6% to 12% of all deliveries, while sterilizations remained stable at 11% (pwomen with either public or private insurance who had financial access to both sterilization (n=253) and IUD (n=223). Women receiving sterilization were slightly older (mean age 31 years versus 30 years, p=.03), of higher parity (median three versus two, pwomen who received IUD. Approximately 45% of women delivering in Oregon in 2007 were publicly insured (2010 Maternal and Child Health Update: States Make Progress Towards Improving Systems of Care. National Governor's Association, Table 6. Available at http://www.nga.org/files/live/sites/NGA/files/pdf/MCHUPDATE2010.PDF, accessed Nov 2011). After adjusting for age, parity and type of delivery, women choosing sterilization were more likely to have public insurance than women choosing IUD (odds ratio 8.4, 95% confidence interval 4.7-14.9, pWomen choosing sterilization are more likely to have public insurance than women choosing IUD and may represent a continued trend toward nonreversible contraception among women of lower socioeconomic status despite available long-acting reversible methods. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Sterile Neutrinos in Cold Climates

    International Nuclear Information System (INIS)

    Jones, Benjamin J.P.

    2015-01-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin 2 2θ 24 ≤ 0.02 at m 2 ~ 0.3 eV 2 , and the LSND and MiniBooNE allowed regions are excluded at

  15. [Sterilization and eugenics].

    Science.gov (United States)

    Shasha, Shaul M

    2011-04-01

    The term "eugenics" was coined by Francis Galton in 1883 and was defined as the science of the improvement of the human race by better breeding. "Positive eugenics" referred to methods of encouraging the "most fit" to reproduce more often, while "negative eugenics" was related to ways of discouraging or preventing the "less fit" from reproducing by birth control and sterilization. Many western countries adopted eugenics programs including Britain, Canada, Norway, Australia, Switzerland and others. In Sweden more then 62,000 "unfits" were forcibly sterilized. Many states in the U.S.A. had adopted marriage laws with eugenics criteria including forced sterilization. Approximately 64,000 individuals were sterilized. Eugenics considerations also lay behind the adoption of the Immigration Restriction Act of 1924. The Largest plan on eugenics was adopted by the Nazi regime in Germany. Hundreds of thousands of people, who were viewed as being "unfit", were forcibly sterilized by different methods: Surgical sterilization or castration with severe complications and high mortality rates. X-ray irradiation. The method was suggested by Brack, and tested by Schuman using prisoners in Block No. 10 in Auschwitz and Birkenau. Experiments were also performed by Brack on prisoners using the "window method". "Klauberg method"--injection of irritating materials into the uterus. Experiments were conducted using the plant Caladium Seguinum which was believed to have sterilization and castration properties.

  16. Prospects for radiation sterilization of medical products in Egypt

    International Nuclear Information System (INIS)

    Roushdy, H.M.

    1975-01-01

    The pharmaceutical industry in Egypt is continually expanding its activity and each year marks new accomplishments and additions which enable the companies to apply the most modern scientific means in the production of pharmaceutical preparations and consequently to improve their market potentialities. The certainty of expansion and the possibility of increasing exports of sterilized medical products, particularly to Arab and African countries, indicate a need for a gamma-sterilization plant. This technology permits the introduction of the latest practices with regard to used disposables, thus greatly reducing the chances of cross-contamination which usually results in serious complications enhanced by local environmental conditions. This paper reviews the current state and future prospects for radiation sterilization of medical products and biological tissues in connection with other related industrial radiation processings. Moreover, the paper reviews the Egyptian scientific and technical experience with irradiation facilities and the parameters underlying the choice of Egypt's first industrial gamma and electron-beam irradiators designed for more than a single-purpose use, with hygienic measures taken to avoid biological contamination of sterilized medical packages throughout the sterilization process. In addition, the paper deals with the policy set up for establishing the Egyptian National Centre for Radiation Technology with a view to introducing irradiation techniques in the sterilization of medical products, and to improving the properties and increasing the competitiveness of Egyptian fabrics. Apart from medical sterilization, certain industrial processes have been mentioned to show how a multi-purpose irradiation facility may be utilized in a developing country to justify significantly the large investment required. (author)

  17. Sterilization of health care products - Ethylene oxide - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2007-01-01

    This part of ISO 11135 describes requirements that, if met, will provide an ethylene oxide sterilization process intended to sterilize medical devices, which has appropriate microbicidal activity. Furthermore, compliance with the requirements ensures that this activity is both reliable and reproducible so that it can be predicted, with reasonable confidence, that there is a low level of probability of there being a viable microorganism present on product after sterilization. Specification of this probability is a matter for regulatory authorities and may vary from country to country. The paper provides information on scope, normative references, terms and definitions, quality management systems, sterilizing agent characterization, process and equipment characterization, product definition, process definition, validation, routine monitoring and control, product release from sterilization and maintaining process effectiveness followed by Annex A (Determination of lethal rate of the sterilization process - Biological indicator/bioburden approach), Annex B (Conservative determination of lethal rate of the sterilization process - Overkill approach, annex C (General guidance) and a bibliography.

  18. Reversibility of female sterilization.

    Science.gov (United States)

    Siegler, A M; Hulka, J; Peretz, A

    1985-04-01

    The discussion considers the current status of reversibility of sterilization in the US and describes clinical and experimental efforts for developing techniques designed for reversibility. It focuses on regret following sterilization, reversal potential of current sterilization techniques, patient selection, current reversal techniques, results of sterilization procedures, experimental approaches to reversal of current techniques of sterilization, and sterilization procedures devised for reversibility, in humans and in animals. Request is the 1st stage of reversal, but a request for sterilization reversal (SR) does not always mean regret for a decision made at the time. Frequently it is a wish to restore fertility because life circumstances have changed after a sterilization that was ppropriate at the time it was performed. Schwyhart and Kutner reviewed 22 studies published between 1949-69 in which they found that the percentage of patients regretting the procedure ranged from 1.3-15%. Requests for reversal remain low in most countries, but if sterilization becomes a more popular method of contraception, requests will also increase. The ideal operation considered as a reversaible method of sterilization should include an easy, reliable outpatient method of tubal occlusion with miniml risk or patient discomfort that subsequently could be reversed without the need for a major surgical intervention. Endoscopic methods have progressed toward the 1st objective. A recent search of the literature uncovered few series of SR of more than 50 cases. The 767 operations found were analyzed with regard to pregnancy outcome. The precent of live births varied from 74-78.8%, and the occurance of tubal pregnancies ranged from 1.7-6.5%. All of the confounding variables in patient selection and small numbers of reported procedures preclude any conclusion about the different techniques or the number of operations that give a surgeon a level of expertise. Few authors classify their

  19. Safety and efficacy of hysteroscopic sterilization compared with laparoscopic sterilization: an observational cohort study

    Science.gov (United States)

    Mao, Jialin; Pfeifer, Samantha; Schlegel, Peter

    2015-01-01

    Objective To compare the safety and efficacy of hysteroscopic sterilization with the “Essure” device with laparoscopic sterilization in a large, all-inclusive, state cohort. Design Population based cohort study. Settings Outpatient interventional setting in New York State. Participants Women undergoing interval sterilization procedure, including hysteroscopic sterilization with Essure device and laparoscopic surgery, between 2005 and 2013. Main outcomes measures Safety events within 30 days of procedures; unintended pregnancies and reoperations within one year of procedures. Mixed model accounting for hospital clustering was used to compare 30 day and 1 year outcomes, adjusting for patient characteristics and other confounders. Time to reoperation was evaluated using frailty model for time to event analysis. Results We identified 8048 patients undergoing hysteroscopic sterilization and 44 278 undergoing laparoscopic sterilization between 2005 and 2013 in New York State. There was a significant increase in the use of hysteroscopic procedures during this period, while use of laparoscopic sterilization decreased. Patients undergoing hysteroscopic sterilization were older than those undergoing laparoscopic sterilization and were more likely to have a history of pelvic inflammatory disease (10.3% v 7.2%, P<0.01), major abdominal surgery (9.4% v 7.9%, P<0.01), and cesarean section (23.2% v 15.4%, P<0.01). At one year after surgery, hysteroscopic sterilization was not associated with a higher risk of unintended pregnancy (odds ratio 0.84 (95% CI 0.63 to 1.12)) but was associated with a substantially increased risk of reoperation (odds ratio 10.16 (7.47 to 13.81)) compared with laparoscopic sterilization. Conclusions Patients undergoing hysteroscopic sterilization have a similar risk of unintended pregnancy but a more than 10-fold higher risk of undergoing reoperation compared with patients undergoing laparoscopic sterilization. Benefits and risks of both procedures

  20. Radiation sterilization of medical products

    International Nuclear Information System (INIS)

    Khurshid, S.J.; Hussain, A.M.

    1989-01-01

    Radiation sterilization is the best method of sterilization, essentially for single use medical and surgical products. Pakistan has established a commercial gamma irradiation plant for this purpose. This article overviews the advantages and benefits of radiation sterilization to stimulate the interest of industrialists and the users in this technology. This technology can give a better medical care in the country and the growing demand can only be met by bulk sterilization. The radiation sterilized medical products can also compete well with the products sterilized by other methods in the international market, gamma sterilization is accepted internationally and if adopted it can boost our export of medical products. (author)

  1. Development of female medfly attractant systems for trapping and sterility assessment. Proceedings of a final research co-ordination meeting

    International Nuclear Information System (INIS)

    1999-07-01

    Practical application of the sterile insect technique (SIT) against major insect pests will continue to increase as the repeated use of insecticides is recognized as an environmental problem. In the case of the Mediterranean fruit fly (medfly), which attacks over 300 species of fruits and vegetables in tropical, subtropical, and temperate climates on all five continents, control is still largely based on frequent insecticide spraying, often more than 10 sprays per fruiting season. Methods for population estimation, which accurately reflect changes due to movement, mortality or reproduction, are a prerequisite for effective pest management and in particular for use of SIT. With better monitoring tools medfly populations can be estimated more accurately and compared under different conditions, to guide decisions on alternative (i.e. more effective and more environment-friendly) control strategies. In support of this need in the application of SIT field programmes against medfly, an FAO/IAEA co-ordinated research project (CRP) was carried out which resulted in a TECDOC published in 1996 on Standardization of Medfly Trapping for Use in sterile insect technique Programmes. Following the development of male only genetic sexing strains at the FAO/IAEA Agriculture and Biotechnology Laboratories in Seibersdorf, Austria, it was recognized that the development of a female medfly targeted trapping system, in conjunction with only male sterile releases, would improve the efficacy of the SIT, reduce costs, and more effectively utilize sterile males. As a result, a new FAO/IAEA Co-ordinated Research Project on Development of Female Medfly Attractant Systems for Trapping and Sterility Assessment was initiated in 1994 with the objective to develop new synthetic female medfly attractants and to determine their efficacy compared to proteinaceous baits under different weather, host-tree and population density conditions. Findings obtained during the course of this 5-year CRP are

  2. Development of female medfly attractant systems for trapping and sterility assessment. Proceedings of a final research co-ordination meeting

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    Practical application of the sterile insect technique (SIT) against major insect pests will continue to increase as the repeated use of insecticides is recognized as an environmental problem. In the case of the Mediterranean fruit fly (medfly), which attacks over 300 species of fruits and vegetables in tropical, subtropical, and temperate climates on all five continents, control is still largely based on frequent insecticide spraying, often more than 10 sprays per fruiting season. Methods for population estimation, which accurately reflect changes due to movement, mortality or reproduction, are a prerequisite for effective pest management and in particular for use of SIT. With better monitoring tools medfly populations can be estimated more accurately and compared under different conditions, to guide decisions on alternative (i.e. more effective and more environment-friendly) control strategies. In support of this need in the application of SIT field programmes against medfly, an FAO/IAEA co-ordinated research project (CRP) was carried out which resulted in a TECDOC published in 1996 on Standardization of Medfly Trapping for Use in sterile insect technique Programmes. Following the development of male only genetic sexing strains at the FAO/IAEA Agriculture and Biotechnology Laboratories in Seibersdorf, Austria, it was recognized that the development of a female medfly targeted trapping system, in conjunction with only male sterile releases, would improve the efficacy of the SIT, reduce costs, and more effectively utilize sterile males. As a result, a new FAO/IAEA Co-ordinated Research Project on Development of Female Medfly Attractant Systems for Trapping and Sterility Assessment was initiated in 1994 with the objective to develop new synthetic female medfly attractants and to determine their efficacy compared to proteinaceous baits under different weather, host-tree and population density conditions. Findings obtained during the course of this 5-year CRP are

  3. Methods of sterilization and monitoring of sterilization across selected dental practices in karachi, pakistan

    International Nuclear Information System (INIS)

    Ahmed, H.

    2015-01-01

    To assess methods of sterilization in dental practices in Karachi and secondly to investigate methods of monitoring sterilization in dental practices in Karachi, Pakistan. Study Design: Cross-sectional, descriptive study. Place and Duration of Study: Dental colleges, hospitals and private clinics of Karachi, Pakistan, from January to March 2013. Methodology: A total of 251 questionnaires were obtained. Descriptive statistics were computed and differences between groups were assessed through chi-square test using Statistical Package for the Social Sciences (SPSS) version 16.0. P-value < 0.05 was taken as statistically significant. Results: Autoclave, used by 155 (61.8%) dentists was the most common method of sterilization followed by more than one method, 65 (25.9%); dry heat, 24 (9.6%); and cold sterilization, 7 (2.8%). Majority of dentists, 126 (50.1%), never monitored sterilization and those who did monitored mostly monthly. Statistically significant difference was found amongst the three groups of dentists monitoring sterilization (p=0.09) and methods of sterilization (p < 0.01). Conclusion: Statistically significant difference was found in infection control practices of specialists, postgraduate trainees and general dentists regarding method of monitoring sterilization with majority of dentists never monitoring sterilization. (author)

  4. Sterilization of health care products - Radiation. Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2006-01-01

    A sterile medical device is one that is free of viable microorganisms. International Standards, which specify requirements for validation and routine control of sterilization processes, require, when it is necessary to supply a sterile medical device, that adventitious microbiological contamination of a medical device prior to sterilization be minimized. Even so, medical devices produced under standard manufacturing conditions in accordance with the requirements for quality management systems (see, for example, ISO 13485) may, prior to sterilization, have microorganisms on them, albeit in low numbers. Such medical devices are non-sterile. The purpose of sterilization is to inactivate the microbiological contaminants and thereby transform the nonsterile medical devices into sterile ones. The kinetics of inactivation of a pure culture of microorganisms by physical and/or chemical agents used to sterilize medical devices can generally best be described by an exponential relationship between the numbers of microorganisms surviving and the extent of treatment with the sterilizing agent; inevitably this means that there is always a finite probability that a microorganism may survive regardless of the extent of treatment applied. For a given treatment, the probability of survival is determined by the number and resistance of microorganisms and by the environment in which the organisms exist during treatment. It follows that the sterility of any one medical device in a population subjected to sterilization processing cannot be guaranteed and the sterility of a processed population is defined in terms of the probability of there being a viable microorganism present on a medical device. This part of ISO 11137 describes requirements that, if met, will provide a radiation sterilization process intended to sterilize medical devices, that has appropriate microbicidal activity. Furthermore, compliance with the requirements ensures that this activity is both reliable and

  5. Radiosterilization and gas sterilization

    International Nuclear Information System (INIS)

    Schultz, H.A.; Gruenewald, T.

    1987-01-01

    The book presents a survey of the principles of cold sterilization by radiation or gas, and also of the problems involved. The reader who has to do with sterilization of some kind or other, as e.g. sterilization of medicaments, medical supplies, medical device, drugs, grafts, or food, will find comprehensive information on the various available methods and their effects, as well as on monitoring procedures and techniques, together with proposals for efficient documentation and validation of partial sterilization processes. The introduction summarizes the potentials of sterilization by radiation, and the subsequent by radiation, and the subsequent chapters explain the specific applicabilities of radiosterilization along with the most important criteria for evaluating the sterilizing efficiency. The information on the legal situation and requirements takes into account the second amendment of the Medical Preparations Act. With 38 figs., 14 tabs [de

  6. Radiation sterilization of medical products- current trends and future prospects

    International Nuclear Information System (INIS)

    Sharma, G.

    1997-01-01

    In medical practice use of sterile pharmaceuticals and single use disposable medical devices is steadily increasing. Sterile pharmaceuticals like injections and ophthalmic ointments are required for therapy. Medical devices are employed for diagnostic, drug administration or corrective purposes, and as implants for temporary, short term or long term residence in the human system. All these products are made available in sterile form by treating them to a suitable process of sterilization i.e. dry/wet heat, ethylene oxide (EtO) gas or ionizing radiation. In this paper current trends and future prospects of radiation sterilization of medical products are given in detail. 9 refs., 7 tabs

  7. Validation of the efficacy of a solar-thermal powered autoclave system for off-grid medical instrument wet sterilization.

    Science.gov (United States)

    Kaseman, Tremayne; Boubour, Jean; Schuler, Douglas A

    2012-10-01

    This work describes the efficacy of a solar-thermal powered autoclave used for the wet sterilization of medical instruments in off-grid settings where electrical power is not readily available. Twenty-seven trials of the solar-thermal powered system were run using an unmodified non-electric autoclave loaded with a simulated bundle of medical instruments and biological test agents. Results showed that in 100% of the trials the autoclave achieved temperatures in excess of 121°C for 30 minutes, indicator tape displayed visible reactions to steam sterilization, and biological tests showed that microbial agents had been eliminated, in compliance with the Centers for Disease Control and Prevention requirements for efficacious wet sterilization.

  8. Studies on the male sterility-fertility restoration system of AE. Kotschyi 19

    International Nuclear Information System (INIS)

    Cheng Junyuan; Sun Guoqing; Liu Luxiang; Zhao Linshu; Lu Xiuxia

    1996-01-01

    Sterile plants were obtained from the distant hybridization between Ae. Kotschyi 19 as the female parent and the Chinese Spring and T. yunnanense King as the male parent. Common wheat lines were used to testcross and backcross with the F 1 sterile plants successively. Male sterile line K-19 with Ae. Kotschyi cytoplasm and common wheat nucleus was bred. Over 10 K-19 MS lines were obtained. They are steady without monoploid. 7 restorers were obtained with the restoring ability from 88.2% to 96.9% according to the domestic method, from 116.4% to 150.4% according to the international method

  9. Effects of Sterilization Cycles on PEEK for Medical Device Application

    Science.gov (United States)

    Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-01-01

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed. PMID:29466289

  10. Effects of Sterilization Cycles on PEEK for Medical Device Application.

    Science.gov (United States)

    Kumar, Amit; Yap, Wai Teng; Foo, Soo Leong; Lee, Teck Kheng

    2018-02-21

    The effects of the sterilization process have been studied on medical grade thermoplastic polyetheretherketone (PEEK). For a reusable medical device, material reliability is an important parameter to decide its lifetime, as it will be subjected to the continuous steam sterilization process. A spring nature, clip component was selected out of a newly designed medical device (patented) to perform this reliability study. This clip component was sterilized for a predetermined number of cycles (2, 4, 6, 8, 10, 20…100) at 121 °C for 30 min. A significant decrease of ~20% in the compression force of the spring was observed after 30 cycles, and a ~6% decrease in the lateral dimension of the clip was observed after 50 cycles. No further significant change in the compression force or dimension was observed for the subsequent sterilization cycles. Vickers hardness and differential scanning calorimetry (DSC) techniques were used to characterize the effects of sterilization. DSC results exhibited no significant change in the degree of cure and melting behavior of PEEK before and after the sterilization. Hardness measurement exhibited an increase of ~49% in hardness after just 20 cycles. When an unsterilized sample was heated for repetitive cycles without the presence of moisture (121 °C, 10 and 20 cycles), only ~7% of the maximum change in hardness was observed.

  11. Audits of radiation sterilization facilities

    International Nuclear Information System (INIS)

    Kelkar, Prabhakar M.

    2001-01-01

    Johnson and Johnson is the world leader in sterilization science and technology. A special group of scientists and technologists are engaged in the development of new methods of sterilization, worldwide monitoring of sterilization processes, equipment and approvals for all types of sterilization processes. Kilmer Conference in the alternate year for the benefit of all those involved in improvement in sterilization science is held. Cobalt-60 gamma radiation for sterilization of medical products on commercial scale is used. This kind of mammoth task can only be achieved through systematic method of planning, auditing, expert review and approval of facilities

  12. Male and female sterility in Zambia

    Directory of Open Access Journals (Sweden)

    Athena Pantazis

    2014-02-01

    Full Text Available Background: Population measures of sterility are traditionally constructed for women, despite fertility and sterility being conditions of the couple. Estimates of male sterility provide insight into population-level sterility, and complement estimates based solely on women. Objective: This study seeks to estimate male sterility for the Gwembe Tonga of Zambia using male birth histories collected by the Gwembe Tonga Research Project from 1957 to 1995, while providing context by estimating female sterility for the Gwembe Tonga, as well as female sterility in all of Zambia, from Zambian DHS data (1992, 1997, 2001-02, and 2007. Methods: Sterility is measured using the Larson-Menken subsequently infertile indicator. Estimates are produced using discrete time event history analysis. Results: The odds of sterility were higher for women than men, though women's odds of sterility were only 1.5 times that of men's in the middle reproductive years. The odds of sterility increased steadily with age for both men and women, and across all datasets. However, women's sterility increased much more sharply with age than men's did, and women's odds of sterility were higher than men's at all reproductive ages.

  13. The role of meiotic drive in hybrid male sterility.

    Science.gov (United States)

    McDermott, Shannon R; Noor, Mohamed A F

    2010-04-27

    Meiotic drive causes the distortion of allelic segregation away from Mendelian expected ratios, often also reducing fecundity and favouring the evolution of drive suppressors. If different species evolve distinct drive-suppressor systems, then hybrid progeny may be sterile as a result of negative interactions of these systems' components. Although the hypothesis that meiotic drive may contribute to hybrid sterility, and thus species formation, fell out of favour early in the 1990s, recent results showing an association between drive and sterility have resurrected this previously controversial idea. Here, we review the different forms of meiotic drive and their possible roles in speciation. We discuss the recent empirical evidence for a link between drive and hybrid male sterility, also suggesting a possible mechanistic explanation for this link in the context of chromatin remodelling. Finally, we revisit the population genetics of drive that allow it to contribute to speciation.

  14. Radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Kaluska, I.; Stuglik, Z.

    1996-01-01

    Overview of sterilization methods of medical devices has been given, with the special stress put on radiation sterilization. A typical validation program for radiation sterilization has been shown and also a comparison of European and ISO standards concerning radiation sterilization has been discussed. (author). 13 refs, 1 fig., 2 tabs

  15. Sterile Neutrinos in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Benjamin J.P. [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2015-09-01

    Measurements of neutrino oscillations at short baselines contain an intriguing set of experimental anomalies that may be suggestive of new physics such as the existence of sterile neutrinos. This three-part thesis presents research directed towards understanding these anomalies and searching for sterile neutrino oscillations. Part I contains a theoretical discussion of neutrino coherence properties. The open-quantum-system picture of neutrino beams, which allows a rigorous prediction of coherence distances for accelerator neutrinos, is presented. Validity of the standard treatment of active and sterile neutrino oscillations at short baselines is verified, and non-standard coherence loss effects at longer baselines are predicted. Part II concerns liquid argon detector development for the MicroBooNE experiment, which will search for short-baseline oscillations in the Booster Neutrino Beam at Fermilab. Topics include characterization and installation of the MicroBooNE optical system; test-stand measurements of liquid argon optical properties with dissolved impurities; optimization of wavelength-shifting coatings for liquid argon scintillation light detection; testing and deployment of high-voltage surge arrestors to protect TPC field cages; and software development for optical and TPC simulation and reconstruction. Part III presents a search for sterile neutrinos using the IceCube neutrino telescope, which has collected a large sample of atmospheric-neutrino-induced events in the 1-10 TeV energy range. Sterile neutrinos would modify the detected neutrino flux shape via MSW-resonant oscillations. Following a careful treatment of systematic uncertainties in the sample, no evidence for MSW-resonant oscillations is observed, and exclusion limits on 3+1 model parameter space are derived. Under the mixing assumptions made, the 90% confidence level exclusion limit extends to sin224 ≤ 0.02 at m2 ~ 0.3 eV2, and the LSND and Mini

  16. Population suppression in support of the sterile insect technique

    International Nuclear Information System (INIS)

    Mangan, R.L.

    2005-01-01

    Suppression or eradication of insect pest populations by the release of sterile insects is often dependent on supplementary methods of pest reduction to levels where the target pest population can be overflooded with sterile insects. Population suppression activities take place in advance of, or coincide with, the production of sterile insects. Supplementary methods to remove breeding opportunities, or management methods that prevent access of pests to the hosts, may reduce the population or prevent damage. Insecticides have been used widely in direct applications or applied as baits, in traps, or on specific sites where the pest makes contact or reproduces. As sterile insect release does not kill the pest, adult biting pests or fertile mated females of the pests will continue to attack hosts after the release of sterile insects. Thus supplementary pest suppression programmes and quarantine measures are essential to prevent damage or the spread of disease. Eradication or effective pest management requires that the entire population of the pest be treated, or that the programme apply immigration barriers. When supplementary pest control activities benefit the human population in areas being treated, such as in mosquito or screwworm eradication programmes, these activities are usually acceptable to the public, but when the public receives no direct benefit from supplementary control activities such as in fruit fly programmes, social resistance may develop. (author)

  17. 21 CFR 522.1881 - Sterile prednisolone acetate aqueous suspension.

    Science.gov (United States)

    2010-04-01

    ... and for various stress conditions when corticosteroids are required while the animal is being treated... SERVICES (CONTINUED) ANIMAL DRUGS, FEEDS, AND RELATED PRODUCTS IMPLANTATION OR INJECTABLE DOSAGE FORM NEW ANIMAL DRUGS § 522.1881 Sterile prednisolone acetate aqueous suspension. (a) Specifications. Each...

  18. Modified Baryonic Dynamics: two-component cosmological simulations with light sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Angus, G.W.; Gentile, G. [Department of Physics and Astrophysics, Vrije Universiteit Brussel, Pleinlaan 2, Brussels, 1050 Belgium (Belgium); Diaferio, A. [Dipartimento di Fisica, Università di Torino, Via P. Giuria 1, Torino, I-10125 Italy (Italy); Famaey, B. [Observatoire astronomique de Strasbourg, CNRS UMR 7550, Université de Strasbourg, 11 rue de l' Université, Strasbourg, F-67000 France (France); Heyden, K.J. van der, E-mail: garry.angus@vub.ac.be, E-mail: diaferio@ph.unito.it, E-mail: benoit.famaey@astro.unistra.fr, E-mail: gianfranco.gentile@ugent.be, E-mail: heyden@ast.uct.ac.za [Astrophysics, Cosmology and Gravity Centre, Dept. of Astronomy, University of Cape Town, Private Bag X3, Rondebosch, 7701 South Africa (South Africa)

    2014-10-01

    In this article we continue to test cosmological models centred on Modified Newtonian Dynamics (MOND) with light sterile neutrinos, which could in principle be a way to solve the fine-tuning problems of the standard model on galaxy scales while preserving successful predictions on larger scales. Due to previous failures of the simple MOND cosmological model, here we test a speculative model where the modified gravitational field is produced only by the baryons and the sterile neutrinos produce a purely Newtonian field (hence Modified Baryonic Dynamics). We use two-component cosmological simulations to separate the baryonic N-body particles from the sterile neutrino ones. The premise is to attenuate the over-production of massive galaxy cluster halos which were prevalent in the original MOND plus light sterile neutrinos scenario. Theoretical issues with such a formulation notwithstanding, the Modified Baryonic Dynamics model fails to produce the correct amplitude for the galaxy cluster mass function for any reasonable value of the primordial power spectrum normalisation.

  19. Steam sterilization and automatic dispensing of [18F]fludeoxyglucose (FDG) for injection

    International Nuclear Information System (INIS)

    Karwath, Pascal; Sartor, Johannes; Gries, Wolfgang; Wodarski, Christine; Dittmar, Claus; Biersack, Hans J.; Guhlke, Stefan

    2005-01-01

    For the purpose of implementing steam sterilization of 2-[ 18 F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity (∼99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories

  20. Prospects of radiation sterilization of medical devices

    International Nuclear Information System (INIS)

    Hosobuchi, Kazunari

    1992-01-01

    Since radiation sterilization was first introduced in the United States in 1956 in the field of disposable medical devices, it has become an indispensable technique for sterilization because of the following reasons: (1) introduction into dialyzers, (2) introduction in medical device makers, (3) development of disposable medical devices associated with developing both high molecular chemistry and cool sterilization, (4) rationality of sterilization process, and (5) problems of sterilization with ethylene oxide gas. To promote the further development of radiation sterilization, the following items are considered necessary: (1) an increase in the number of facilities for radiation sterilization, (2) recommendation of the international standardization of sterilization method, (3) decrease in radiation doses associated with sterilization, (4) development of electron accelerators and bremsstrahlung equipments for radiation sources, and (5) simplification of sterilization process management. Factors precluding the development of radiation sterilization are: (1) development of other methods than radiation sterilization, (2) development of technique for sterile products, (3) high facility cost, (4) high irradiation cost, (5) benefits and limits of sterilization markets, and (6) influences of materials. (N.K.)

  1. Male sterility of triticale lines generated through recombination of triticale and rye maintainers

    Directory of Open Access Journals (Sweden)

    Tomasz Warzecha

    2014-11-01

    Full Text Available The Triticum timopheevi cytoplasmic male sterility (cms system in triticale (xTriticosecale Wittmack suffers from a low frequency of maintainers and environmental instability of the male sterility. On the other hand, the Pampa cms system in rye (Secale cereale exhibits strong male sterility and a low frequency of restorers. Here, we report generating hybrids between maintainers of the T. timopheevi cms system in triticale and maintainers of the rye Pampa cms system. Ten hybrids were obtained. Their hybridity was verified by PCR (polymerase chain reaction using ISSR (inter simple sequence repeats primers. The cms maintaining ability of F2 individuals and their progeny was tested. The F2 plants were crossed to male sterile lines of triticale carrying the T. timopheevi cytoplasm. Among 180 G1 offspring of these crosses, 71 (39.4% were completely male sterile. Fourteen F2 individuals (7.8%, as well as their F2S1 and progeny, generated stable male sterility in G1, G1BC1 and G1BC2 generations after the crosses. Our results suggest that it is possible to produce a more stable cms system in triticale based on the T. timopheevi cytoplasm as compared to the existing one.

  2. Practical fundamentals of glass, rubber, and plastic sterile packaging systems.

    Science.gov (United States)

    Sacha, Gregory A; Saffell-Clemmer, Wendy; Abram, Karen; Akers, Michael J

    2010-01-01

    Sterile product packaging systems consist of glass, rubber, and plastic materials that are in intimate contact with the formulation. These materials can significantly affect the stability of the formulation. The interaction between the packaging materials and the formulation can also affect the appropriate delivery of the product. Therefore, a parenteral formulation actually consists of the packaging system as well as the product that it contains. However, the majority of formulation development time only considers the product that is contained in the packaging system. Little time is spent studying the interaction of the packaging materials with the contents. Interaction between the packaging and the contents only becomes a concern when problems are encountered. For this reason, there are few scientific publications that describe the available packaging materials, their advantages and disadvantages, and their important product attributes. This article was created as a reference for product development and describes some of the packaging materials and systems that are available for parenteral products.

  3. Study of fieldbus technology applied in a sterilization plant control and safety systems

    International Nuclear Information System (INIS)

    Karam Junior, Dib

    2000-01-01

    Several sterilization processes have been used in these years for treatment of countless products. Some processes use high temperatures, thermal shocks and chemical agents. With the discovery of the ionizing radiation and its posterior technological developments turned possible application of that process, in 1960, also in the the sterilization, denominated radiation sterilization. This process became also applied in another areas of health and industrial as food conservation, gemstones enhancement and others. The radiation sterilization requests an effective control and it needs a high level of safety. The commercial use of the computers applied in industrial automation provides and the domain of new technologies in this field provides new applications then new designs now is possible. The Fieldbus technology, a new digital communication protocol, like a Local Area Network, can be an alternative in the cobalt-60 irradiation plant. The present work suggests, evaluates, qualifies and quantifies this possibility. (author)

  4. Sterilization of space hardware.

    Science.gov (United States)

    Pflug, I. J.

    1971-01-01

    Discussion of various techniques of sterilization of space flight hardware using either destructive heating or the action of chemicals. Factors considered in the dry-heat destruction of microorganisms include the effects of microbial water content, temperature, the physicochemical properties of the microorganism and adjacent support, and nature of the surrounding gas atmosphere. Dry-heat destruction rates of microorganisms on the surface, between mated surface areas, or buried in the solid material of space vehicle hardware are reviewed, along with alternative dry-heat sterilization cycles, thermodynamic considerations, and considerations of final sterilization-process design. Discussed sterilization chemicals include ethylene oxide, formaldehyde, methyl bromide, dimethyl sulfoxide, peracetic acid, and beta-propiolactone.

  5. Regret following female sterilization in Slovenia.

    Science.gov (United States)

    Becner, Anja; Turkanović, Anela Bečić; But, Igor

    2015-07-01

    To estimate the regret rate and risk factors for regret among women who have undergone sterilization. A retrospective study was conducted among all women who underwent a sterilization procedure at the University Medical Center Maribor, Maribor, Slovenia, in 2008-2012. Identified women were contacted and asked to complete an online questionnaire assessing regret and symptoms associated with depression. Among 714 identified women, 308 (43.1%) completed the questionnaire. Four (1.3%) participants reported regret, and 9 (2.9%) reported that they would not opt for sterilization again, all of whom had post-sterilization problems. Such problems were significantly associated with participants reporting that they would not opt for sterilization again (P=0.003). Additionally, women who would not choose sterilization again had significantly higher scores on the depressive scale used than did those who would undergo sterilization again (P=0.028). Few women report regret after tubal sterilization in Slovenia. However, an additional consultation on post-sterilization problems and depressive disorder before sterilization might minimize the risk of regret. Copyright © 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  6. Ozone-mist spray sterilization for pest control in agricultural management

    Science.gov (United States)

    Ebihara, Kenji; Mitsugi, Fumiaki; Ikegami, Tomoaki; Nakamura, Norihito; Hashimoto, Yukio; Yamashita, Yoshitaka; Baba, Seiji; Stryczewska, Henryka D.; Pawlat, Joanna; Teii, Shinriki; Sung, Ta-Lun

    2013-02-01

    We developed a portable ozone-mist sterilization system to exterminate pests (harmful insects) in agricultural field and greenhouse. The system is composed of an ozone generator, an ozone-mist spray and a small container of ozone gas. The ozone generator can supply highly concentrated ozone using the surface dielectric barrier discharge. Ozone-mist is produced using a developed nozzle system. We studied the effects of ozone-mist spray sterilization on insects and agricultural plants. The sterilization conditions are estimated by monitoring the behavior of aphids and observing the damage of the plants. It was shown that aphids were exterminated in 30 s without noticeable damages of the plant leaves. The reactive radicals with strong oxidation potential such as hydroxyl radical (*OH), hydroperoxide radical (*HO2), the superoxide ion radical (*O2‒) and ozonide radical ion (*O3‒) can increase the sterilization rate for aphids. Contribution to the Topical Issue "13th International Symposium on High Pressure Low Temperature Plasma Chemistry (Hakone XIII)", Edited by Nicolas Gherardi, Henryca Danuta Stryczewska and Yvan Ségui.

  7. Production of a sterile species via active-sterile mixing: An exactly solvable model

    Science.gov (United States)

    Boyanovsky, D.

    2007-11-01

    The production of a sterile species via active-sterile mixing in a thermal medium is studied in an exactly solvable model. The exact time evolution of the sterile distribution function is determined by the dispersion relations and damping rates Γ1,2 for the quasiparticle modes. These depend on γ˜=Γaa/2ΔE, with Γaa the interaction rate of the active species in absence of mixing and ΔE the oscillation frequency in the medium without damping. γ˜≪1, γ˜≫1 describe the weak and strong damping limits, respectively. For γ˜≪1, Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where θm is the mixing angle in the medium and the sterile distribution function does not obey a simple rate equation. For γ˜≫1, Γ1=Γaa and Γ2=Γaasin⁡22θm/4γ˜2, is the sterile production rate. In this regime sterile production is suppressed and the oscillation frequency vanishes at an Mikheyev-Smirnov-Wolfenstein (MSW) resonance, with a breakdown of adiabaticity. These are consequences of quantum Zeno suppression. For active neutrinos with standard model interactions the strong damping limit is only available near an MSW resonance if sin⁡2θ≪αw with θ the vacuum mixing angle. The full set of quantum kinetic equations for sterile production for arbitrary γ˜ are obtained from the quantum master equation. Cosmological resonant sterile neutrino production is quantum Zeno suppressed relieving potential uncertainties associated with the QCD phase transition.

  8. Dosimetry requirements derived from the sterilization standards

    DEFF Research Database (Denmark)

    Miller, A.

    1998-01-01

    The main standards for radiation sterilization, ISO 11137 and EN 552, rest the documentation for the properly executed sterilization process on dosimetry. Both standards describe general requirements to the dosimetry system: The dose measurements must be traceable to national standards...... and documented uncertainty limits of the dose measurements can be used to specify process control limits. This is also useful, for example, when dose setting experiments are carried out according to the methods described in ISO 11137, where product samples shall be irradiated within narrow limits......., the uncertainty of the dose measurement and the environmental influences must be known. This paper discusses how to obtain and maintain traceability and how to document measurement uncertainty. The implications of these requirements in the process control of radiation sterilization are further discussed. Known...

  9. Steam sterilization and automatic dispensing of [{sup 18}F]fludeoxyglucose (FDG) for injection

    Energy Technology Data Exchange (ETDEWEB)

    Karwath, Pascal [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany); Sartor, Johannes [MC-Pharma GmbH (MCP), Bonn (Germany); Gries, Wolfgang [MC-Pharma GmbH (MCP), Bonn (Germany); Wodarski, Christine [MC-Pharma GmbH (MCP), Bonn (Germany); Dittmar, Claus [MC-Pharma GmbH (MCP), Bonn (Germany); Biersack, Hans J [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany); Guhlke, Stefan [Department of Nuclear Medicine, University of Bonn, Sigmund-Freud-Strasse 25, 53127 Bonn (Germany) and MC-Pharma GmbH (MCP), Bonn (Germany)

    2005-04-01

    For the purpose of implementing steam sterilization of 2-[{sup 18}F]FDG (FDG) in the final container into routine production, we have validated and established a fully automated dispensing and sterilization system, thereby considerably reducing the radiation burden to the personnel. Methods: The commercially available system combines aseptic dispensing of the product solution under a miniaturized laminar flow unit with subsequent steam sterilization, realized by heating of the product in the final containers by an autoclave included in the dispensing unit, thus incorporating current pharmaceutical manufacturing standards for the production of parental radiopharmaceuticals. The efficiency of the used sterilization cycle, the stability of FDG under the conditions of sterilization and the stability of the final product towards radiolysis was investigated with respect to various pH-formulations. Results: The system was found to be fully valid for filling of vials in a laminar flow class A (US-class 100) environment and for sterilization of FDG in the final container. The pH for sterilizing FDG solutions must be slightly acidic to avoid decomposition. A pH of 5.5 appears to be optimal and gives FDG of very high radiochemical purity ({approx}99%). In addition, radiolysis of FDG in solutions of high activity concentration was significantly lower at pH 5.5 than at neutral pH. Conclusion: Terminal sterilization enables the production of FDG in full compliance with GMP-regulations even in Class C or D (US class 10,000 or 100,000) laboratories.

  10. Sterilizing insects with ionizing radiation

    International Nuclear Information System (INIS)

    Bakri, A.; Mehta, K.; Lance, D.R.

    2005-01-01

    Exposure to ionizing radiation is currently the method of choice for rendering insects reproductively sterile for area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT). Gamma radiation from isotopic sources (cobalt-60 or caesium-137) is most often used, but high-energy electrons and X-rays are other practical options. Insect irradiation is safe and reliable when established safety and quality-assurance guidelines are followed. The key processing parameter is absorbed dose, which must be tightly controlled to ensure that treated insects are sufficiently sterile in their reproductive cells and yet able to compete for mates with wild insects. To that end, accurate dosimetry (measurement of absorbed dose) is critical. Irradiation data generated since the 1950s, covering over 300 arthropod species, indicate that the dose needed for sterilization of arthropods varies from less than 5 Gy for blaberid cockroaches to 300 Gy or more for some arctiid and pyralid moths. Factors such as oxygen level, and insect age and stage during irradiation, and many others, influence both the absorbed dose required for sterilization and the viability of irradiated insects. Consideration of these factors in the design of irradiation protocols can help to find a balance between the sterility and competitiveness of insects produced for programmes that release sterile insects. Many programmes apply 'precautionary' radiation doses to increase the security margin of sterilization, but this overdosing often lowers competitiveness to the point where the overall induced sterility in the wild population is reduced significantly. (author)

  11. Eugenics and Involuntary Sterilization: 1907-2015.

    Science.gov (United States)

    Reilly, Philip R

    2015-01-01

    In England during the late nineteenth century, intellectuals, especially Francis Galton, called for a variety of eugenic policies aimed at ensuring the health of the human species. In the United States, members of the Progressive movement embraced eugenic ideas, especially immigration restriction and sterilization. Indiana enacted the first eugenic sterilization law in 1907, and the US Supreme Court upheld such laws in 1927. State programs targeted institutionalized, mentally disabled women. Beginning in the late 1930s, proponents rationalized involuntary sterilization as protecting vulnerable women from unwanted pregnancy. By World War II, programs in the United States had sterilized approximately 60,000 persons. After the horrific revelations concerning Nazi eugenics (German Hereditary Health Courts approved at least 400,000 sterilization operations in less than a decade), eugenic sterilization programs in the United States declined rapidly. Simplistic eugenic thinking has faded, but coerced sterilization remains widespread, especially in China and India. In many parts of the world, involuntary sterilization is still intermittently used against minority groups.

  12. The possibility of gamma ray sterilization by using ITU TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Bilge, A.N.; Tugrul, B.; Yavuz, H.

    1988-01-01

    Gamma rays are one of the effective method for sterilization which is preferred for a long time. Generally Co-60 radioisotope sources betatrons or accelerators are used for the sterilization. In this work, it was aimed to find the possibilities of the sterilization by gamma rays obtained in ITU TRIGA Mark-II radial tube. Radiation dosages are measured in the radial tube and several medical products are irradiated. Irradiation is arranged according to the desired dosages. Irradiated sterilized goods (mainly medical products) tested and checked at the Governmental Medical Health Center and results compared with literature. It can be seen that this kind of irradiation is a good tool for sterilization. Unfortunately, because of the stability of the radial tube and impracticality of the system it is rather difficult to compete with industrial system using Co-60 and accelerators. Nevertheless, this type of irradiation is also applicable for the purpose of the sterilization by using ITU TRIGA Mark II. (author)

  13. Status and potential of F1 sterility for control of European corn borer, Ostrinia nubilalis Hb

    International Nuclear Information System (INIS)

    Rosca, I.; Barbulescu, A.

    1994-01-01

    In certain lepidopterous insects partially gamma-ray-sterilized males mated with normal females produce progeny which are more sterile than their male parents. Inherited sterility has been observed in numerous pests including the European corn borer, Ostrinia nubilalis Hb. The most important discoveries contributing the development of this techniques are reviewed. The studies on the European corn borer have revealed a dramatic inherited sterility effect when pupae have been irradiated with a low dose of 100 or 150 Gy. Data on the growth, development and behaviour of F 1 individuals indicate that the treated insects are highly competitive with the normal insects. Field tests of the inherited sterility technique in isolated O. nubilalis infestations have indicated that this method is effective and a small eradication has been done. These studies are continuing. (author)

  14. Establishment of a sterilization dose

    International Nuclear Information System (INIS)

    Kaluska, I.

    2007-01-01

    Factors that impact on product bioburden (population of diable microorganisms on or in product and/or sterile barrier system) are: Raw materials, components, product design and size, manufacturing process, manufacturing equipment, manufacturing environment and manufacturing location. Presented lecture describes all these factors in details

  15. Atmospheric-pressure plasma decontamination/sterilization chamber

    Science.gov (United States)

    Herrmann, Hans W.; Selwyn, Gary S.

    2001-01-01

    An atmospheric-pressure plasma decontamination/sterilization chamber is described. The apparatus is useful for decontaminating sensitive equipment and materials, such as electronics, optics and national treasures, which have been contaminated with chemical and/or biological warfare agents, such as anthrax, mustard blistering agent, VX nerve gas, and the like. There is currently no acceptable procedure for decontaminating such equipment. The apparatus may also be used for sterilization in the medical and food industries. Items to be decontaminated or sterilized are supported inside the chamber. Reactive gases containing atomic and metastable oxygen species are generated by an atmospheric-pressure plasma discharge in a He/O.sub.2 mixture and directed into the region of these items resulting in chemical reaction between the reactive species and organic substances. This reaction typically kills and/or neutralizes the contamination without damaging most equipment and materials. The plasma gases are recirculated through a closed-loop system to minimize the loss of helium and the possibility of escape of aerosolized harmful substances.

  16. Auditory display as feedback for a novel eye-tracking system for sterile operating room interaction.

    Science.gov (United States)

    Black, David; Unger, Michael; Fischer, Nele; Kikinis, Ron; Hahn, Horst; Neumuth, Thomas; Glaser, Bernhard

    2018-01-01

    The growing number of technical systems in the operating room has increased attention on developing touchless interaction methods for sterile conditions. However, touchless interaction paradigms lack the tactile feedback found in common input devices such as mice and keyboards. We propose a novel touchless eye-tracking interaction system with auditory display as a feedback method for completing typical operating room tasks. Auditory display provides feedback concerning the selected input into the eye-tracking system as well as a confirmation of the system response. An eye-tracking system with a novel auditory display using both earcons and parameter-mapping sonification was developed to allow touchless interaction for six typical scrub nurse tasks. An evaluation with novice participants compared auditory display with visual display with respect to reaction time and a series of subjective measures. When using auditory display to substitute for the lost tactile feedback during eye-tracking interaction, participants exhibit reduced reaction time compared to using visual-only display. In addition, the auditory feedback led to lower subjective workload and higher usefulness and system acceptance ratings. Due to the absence of tactile feedback for eye-tracking and other touchless interaction methods, auditory display is shown to be a useful and necessary addition to new interaction concepts for the sterile operating room, reducing reaction times while improving subjective measures, including usefulness, user satisfaction, and cognitive workload.

  17. Study of sexual functioning and disorder in women before and after tubal sterilization (tubectomy)

    OpenAIRE

    Kunkeri, Shweta Patil; Sathyanarayana Rao, T. S.; Andrade, Chittaranjan

    2017-01-01

    Introduction: Sexual relationship is a basis for mental health and continuity of the healthy generation. There are very few studies on the female sexual functioning, especially in India. Sterilization being the most common contraceptive method, sexual functioning in women undergoing this surgical intervention has not been adequately explored. Available studies have found conflicting results; some have reported that sterilization has positive effects on sexual functioning since anxiety of gett...

  18. A simple genetic incompatibility causes hybrid male sterility in mimulus.

    Science.gov (United States)

    Sweigart, Andrea L; Fishman, Lila; Willis, John H

    2006-04-01

    Much evidence has shown that postzygotic reproductive isolation (hybrid inviability or sterility) evolves by the accumulation of interlocus incompatibilities between diverging populations. Although in theory only a single pair of incompatible loci is needed to isolate species, empirical work in Drosophila has revealed that hybrid fertility problems often are highly polygenic and complex. In this article we investigate the genetic basis of hybrid sterility between two closely related species of monkeyflower, Mimulus guttatus and M. nasutus. In striking contrast to Drosophila systems, we demonstrate that nearly complete hybrid male sterility in Mimulus results from a simple genetic incompatibility between a single pair of heterospecific loci. We have genetically mapped this sterility effect: the M. guttatus allele at the hybrid male sterility 1 (hms1) locus acts dominantly in combination with recessive M. nasutus alleles at the hybrid male sterility 2 (hms2) locus to cause nearly complete hybrid male sterility. In a preliminary screen to find additional small-effect male sterility factors, we identified one additional locus that also contributes to some of the variation in hybrid male fertility. Interestingly, hms1 and hms2 also cause a significant reduction in hybrid female fertility, suggesting that sex-specific hybrid defects might share a common genetic basis. This possibility is supported by our discovery that recombination is reduced dramatically in a cross involving a parent with the hms1-hms2 incompatibility.

  19. Control and Constraint for Low-Income Women Choosing Outpatient Sterilization

    Science.gov (United States)

    Leyser-Whalen, Ophra; Berenson, Abbey B.

    2012-01-01

    Little is known about Hispanics and their contraceptive choices in general, with some past studies detailing non-consensual sterilization. This article is based on interviews with a mostly Hispanic sample of 44 women being sterilized at a public clinic in southeast Texas with the Essure device, which entails a new outpatient sterilization procedure. These women cited relationship factors, wanting to better their and their children’s lives, and past reproductive histories as reasons for deciding on sterilization. They specifically chose Essure as a result of an apprehension of surgery and potential side effects from tubal ligation. Their choices, however, were limited by larger structural factors of work, family, the political economy, and the health care system. We conclude that this new sterilization technique provided more contraceptive choices for these women, yet more contraceptive decision making autonomy, as well as more equitable social structures, are still needed. PMID:23761929

  20. A general method for identifying major hybrid male sterility genes in Drosophila.

    Science.gov (United States)

    Zeng, L W; Singh, R S

    1995-10-01

    The genes responsible for hybrid male sterility in species crosses are usually identified by introgressing chromosome segments, monitored by visible markers, between closely related species by continuous backcrosses. This commonly used method, however, suffers from two problems. First, it relies on the availability of markers to monitor the introgressed regions and so the portion of the genome examined is limited to the marked regions. Secondly, the introgressed regions are usually large and it is impossible to tell if the effects of the introgressed regions are the result of single (or few) major genes or many minor genes (polygenes). Here we introduce a simple and general method for identifying putative major hybrid male sterility genes which is free of these problems. In this method, the actual hybrid male sterility genes (rather than markers), or tightly linked gene complexes with large effects, are selectively introgressed from one species into the background of another species by repeated backcrosses. This is performed by selectively backcrossing heterozygous (for hybrid male sterility gene or genes) females producing fertile and sterile sons in roughly equal proportions to males of either parental species. As no marker gene is required for this procedure, this method can be used with any species pairs that produce unisexual sterility. With the application of this method, a small X chromosome region of Drosophila mauritiana which produces complete hybrid male sterility (aspermic testes) in the background of D. simulans was identified. Recombination analysis reveals that this region contains a second major hybrid male sterility gene linked to the forked locus located at either 62.7 +/- 0.66 map units or at the centromere region of the X chromosome of D. mauritiana.

  1. Sterile insect technique: A model for dose optimisation for improved sterile insect quality

    International Nuclear Information System (INIS)

    Parker, A.; Mehta, K.

    2007-01-01

    The sterile insect technique (SIT) is an environment-friendly pest control technique with application in the area-wide integrated control of key pests, including the suppression or elimination of introduced populations and the exclusion of new introductions. Reproductive sterility is normally induced by ionizing radiation, a convenient and consistent method that maintains a reasonable degree of competitiveness in the released insects. The cost and effectiveness of a control program integrating the SIT depend on the balance between sterility and competitiveness, but it appears that current operational programs with an SIT component are not achieving an appropriate balance. In this paper we discuss optimization of the sterilization process and present a simple model and procedure for determining the optimum dose. (author) [es

  2. Women plan condom use after sterilization.

    Science.gov (United States)

    1998-12-01

    Sexual sterilization is highly effective in preventing pregnancy, but it does not protect against sexually transmitted diseases (STDs). People who accept sterilization as their method of family planning therefore need to be encouraged to protect themselves against HIV/AIDS and STDs even after they have been sterilized. Since women return less often to family planning providers following their sterilization procedure, they need to be advised to protect themselves against HIV and STDs before the sterilization is performed. 42% of the 2782 women who underwent tubal sterilizations at the Baylor College of Medicine in Houston during 1991-96 indicated their intention in a cross-sectional study to use condoms after sterilization. 20% of all respondents, aged 18-51 years, had a known risk factor for HIV, and almost 25% reported regular condom use for contraception or disease protection during the 3 months before sterilization. Planned condom use increased from 32% in 1991 to 51% in 1996, irrespective of age, marital status, or ethnic background. Of the 646 women who used condoms before being sterilized, almost half indicated no plans to do so after the procedure. The following factors were associated with condom use: relatively younger age, black ethnicity, unmarried status, history of previous STD, no steady partner, having a higher number of previous sex partners, past use of condoms to prevent disease transmission, and lack of partner involvement in the decision to undergo sterilization.

  3. Sterilization by gamma irradiation

    International Nuclear Information System (INIS)

    Reyes Frias, L.

    1992-01-01

    Since 1980 the National Institute of Nuclear Research counts with an Industrial Gamma Irradiator, for the sterilization of raw materials and finished products. Through several means has been promoted the use of this technology as alternative to conventional methods of sterilization as well as steam treatment and ethylene oxide. As a result of the made promotion this irradiator has come to its saturation limit being the sterilization irradiation one of the main services that National Institute of Nuclear Research offers to producer enterprises of disposable materials of medical use also of raw materials for the elaboration of cosmetic products and pharmaceuticals as well as dehydrated foods. It is presented the trend to the sterilization service by irradiation showed by the compilation data in a survey made by potential customers. (Author)

  4. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Directory of Open Access Journals (Sweden)

    Raquel Galante

    Full Text Available In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation, a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP hydrogel nanoparticles (CS-HNP, with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol. Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  5. About the Sterilization of Chitosan Hydrogel Nanoparticles.

    Science.gov (United States)

    Galante, Raquel; Rediguieri, Carolina F; Kikuchi, Irene Satiko; Vasquez, Pablo A S; Colaço, Rogério; Serro, Ana Paula; Pinto, Terezinha J A

    2016-01-01

    In the last years, nanostructured biomaterials have raised a great interest as platforms for delivery of drugs, genes, imaging agents and for tissue engineering applications. In particular, hydrogel nanoparticles (HNP) associate the distinctive features of hydrogels (high water uptake capacity, biocompatibility) with the advantages of being possible to tailor its physicochemical properties at nano-scale to increase solubility, immunocompatibility and cellular uptake. In order to be safe, HNP for biomedical applications, such as injectable or ophthalmic formulations, must be sterile. Literature is very scarce with respect to sterilization effects on nanostructured systems, and even more in what concerns HNP. This work aims to evaluate the effect and effectiveness of different sterilization methods on chitosan (CS) hydrogel nanoparticles. In addition to conventional methods (steam autoclave and gamma irradiation), a recent ozone-based method of sterilization was also tested. A model chitosan-tripolyphosphate (TPP) hydrogel nanoparticles (CS-HNP), with a broad spectrum of possible applications was produced and sterilized in the absence and in the presence of protective sugars (glucose and mannitol). Properties like size, zeta potential, absorbance, morphology, chemical structure and cytotoxicity were evaluated. It was found that the CS-HNP degrade by autoclaving and that sugars have no protective effect. Concerning gamma irradiation, the formation of agglomerates was observed, compromising the suspension stability. However, the nanoparticles resistance increases considerably in the presence of the sugars. Ozone sterilization did not lead to significant physical adverse effects, however, slight toxicity signs were observed, contrarily to gamma irradiation where no detectable changes on cells were found. Ozonation in the presence of sugars avoided cytotoxicity. Nevertheless, some chemical alterations were observed in the nanoparticles.

  6. Chilled packing systems for fruit flies (Diptera: Tephritidae) in the sterile insect technique

    International Nuclear Information System (INIS)

    Hernandez, Emilio; Escobar, Arseny; Bravo, Bigail; Montoya, Pablo; Secretaria de Agricultura, Ganaderia, Desarrollo Rural, Pesca y Alimentacion

    2010-01-01

    We evaluated three packing systems (PARC boxes, 'GT' screen towers and 'MX' screen towers) for the emergence and sexual maturation of sterile fruit flies, at three adult fl y densities (1, 1.2 and 1.3 fly/cm 2) and three food types. At the lowest density, results showed no significant differences in the longevity and flight ability of adult Anastrepha ludens (Loew) and Anastrepha obliqua Macquart among the three packing systems. Higher densities resulted in a decrease in these parameters. In the evaluation of the three food types, no significant differences were found either on longevity or flight ability of A. ludens. However, the greatest longevity for both sexes A. obliqua was obtained with commercial powdered Mb and the mix of sugar, protein and corn starch on paper (SPCP) food types. The highest value for flight ability in A. obliqua males was obtained with powdered Mb and SPCP food types, and for females with Mb powdered food. Our data indicated that GT and MX screen tower packing systems are an alternative to the PARC boxes, since they were suitable for adult fl y sexual maturation without any harm to their longevity or flight ability. The tested foods were equivalent in both fruit fl y species, with the exception of the agar type for A. obliqua, which yielded the lowest biological parameters evaluated. Our results contribute to the application of new methods for the packing and release of sterile flies in large-scale programs. (author)

  7. Validation of the sterile manufacture of the AAEC MARK III molybdenum-99/techtnetium-99m generator

    International Nuclear Information System (INIS)

    Saunders, M.T.; Drummond, C.M.; Harrison, M.A.

    1982-07-01

    The Mark II molybdenum-99/technetium-99m generator now supplied to hospitals by the Australian Atomic Energy Commission is a non-sterile elution system. The Mark III version will be supplied as a sterile elution system. A validation study has been undertaken to assess the capability of the new production facility, to evaluate up-to-date procedures for manufacturing sterile generators and to demonstrate that a sterile radionuclide generator can be made. Generator manufacturing procedures and a time study of the validation are described. Microbiological methods for monitoring in-process aspects of manufacture, disinfectant efficacy and generator sterility are defined

  8. Male gametophytic sterility. 1 - Gametic sterilities and deletions in petunia

    Energy Technology Data Exchange (ETDEWEB)

    Cornu, A.; Maizonnier, D. (Station d' Amelioration des Plantes de l' I.N.R.A., Dijon (France))

    1982-01-01

    Terminal deletions induced by ionizing radiations in Petunia are not sexually transmitted. Cytogenetic study of plants with a heterozygous deletion and their progenies shows that this lack of transmission is accompanied by a gametic semi-sterility due to the fact that gametes carrying the deleted chromosome are not viable. The interest of such a male sterility with a gametophytic determinism for the study of sporophyte-gametophyte relationships is underlined.

  9. Sterilization: new method options, failure rate info.

    Science.gov (United States)

    1998-01-01

    This article discusses new sterilization methods for tubal ligation, failure rates, and risks for ectopic pregnancy in the US. The Filshie clip, which was developed by Femcare, Ltd. in Nottingham, England, and is distributed by Avalon Medical Corp of Vermont, was approved by the US Food and Drug Administration in September 1996. The company has provided training sessions at major universities nationwide and exhibited at national professional association meetings. A training video and two more films will be available in 1998. The new clip is considered a more modern approach to a tubal occlusion method, which relies on newer materials and solves prior problems. Physicians usually used Falope rings, which had better failure rates than the Hulka clip and bipolar coagulation methods. There is a need for more long-term and large scale information exchange about the new Filshie clip. Some physicians still use the Falope ring because it is cost effective and well-studied. Physicians are warned to continue to advise women about the potential failure rates up to 10 years after sterilization and the 1 in 3 risk of ectopic pregnancy. Counseling about failure rates and the risk of ectopic pregnancy should target women under 30 years old, who have the highest failure rates, and women 30-34 years old. All sterilized women should be advised to seek a provider immediately if they have pregnancy symptoms following sterilization. Counseling should include the issue of "regrets," since it is a permanent method. All women should know about nonpermanent methods and experience a basic informed consent process. Young women and newly divorced women are particularly vulnerable to the "regrets" syndrome.

  10. The smart aerial release machine, a universal system for applying the sterile insect technique.

    Directory of Open Access Journals (Sweden)

    Ruben Leal Mubarqui

    Full Text Available Beyond insecticides, alternative methods to control insect pests for agriculture and vectors of diseases are needed. Management strategies involving the mass-release of living control agents have been developed, including genetic control with sterile insects and biological control with parasitoids, for which aerial release of insects is often required. Aerial release in genetic control programmes often involves the use of chilled sterile insects, which can improve dispersal, survival and competitiveness of sterile males. Currently available means of aerially releasing chilled fruit flies are however insufficiently precise to ensure homogeneous distribution at low release rates and no device is available for tsetse.Here we present the smart aerial release machine, a new design by the Mubarqui Company, based on the use of vibrating conveyors. The machine is controlled through Bluetooth by a tablet with Android Operating System including a completely automatic guidance and navigation system (MaxNav software. The tablet is also connected to an online relational database facilitating the preparation of flight schedules and automatic storage of flight reports. The new machine was compared with a conveyor release machine in Mexico using two fruit flies species (Anastrepha ludens and Ceratitis capitata and we obtained better dispersal homogeneity (% of positive traps, p<0.001 for both species and better recapture rates for Anastrepha ludens (p<0.001, especially at low release densities (<1500 per ha. We also demonstrated that the machine can replace paper boxes for aerial release of tsetse in Senegal.This technology limits damages to insects and allows a large range of release rates from 10 flies/km2 for tsetse flies up to 600,000 flies/km2 for fruit flies. The potential of this machine to release other species like mosquitoes is discussed. Plans and operating of the machine are provided to allow its use worldwide.

  11. Gamma-ray irradiation, autoclave and ethylene oxide sterilization to thermosetting polyurethane: sterilization to polyurethane

    International Nuclear Information System (INIS)

    Hirata, Noriko; Matsumoto, Ken-Ichi; Inishita, Takashi; Takenaka, Yoshinori; Suma, Yasunori; Shintani, Hideharu; National Inst. of Health Sciences, Tokyo

    1995-01-01

    Thermosetting polyurethane (PU) is widely used in a large variety of medical devices. 4,4'-methylenedianiline (MDA) was produced from PU by sterilization and it was studied for the relationship between urethane components or polymer characteristics and formation of MDA upon sterilization, using the commercially available dialyzers fabricated with different combination of isocyanate and polyol. We confirmed that the molecular-weight of polyol influenced the production of MDA upon sterilization. (author)

  12. Radiation sterilization of plastic packing materials and aseptic packaging

    International Nuclear Information System (INIS)

    Tokuoka, Keiko

    1986-01-01

    In the present day of 'satiation', quality, not quantity, is emphasized for foods, the consumers being oriented toward raw and healthy foodstuff. Aseptic Packaging is excellent means of conservation. While conventionally chemicals have been used for sterilization of packing materials for aseptic packaging, the sterilization by radiation is used in part recently. The following are described : history of aseptic packaging and its features, sterilization by radiation, γ-ray sterilization of large-sized containers, the development of an aseptic packaging system using electron rays, the occurrence of offensive odors from packing materials (comparison of odors from various materials, volatile substances occurring in irradiated polyethylene, influence of film grade upon the formation of carboxylic acid, influence of the irradiation conditions upon the occurrences of volatile substances, volatile substances occurring in the irradiation of bag-in-box packing materials), changes in properties of the packing materials. (Mori, K.)

  13. Materials Surfaces and sterility

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, R.

    2001-04-01

    A question of great interest in sterile and clean room technology is how can we devise a standard for the guarantee of sterility? Sterility is of widespread importance: it gives the life-time of our daily milk or yogurt, dominates the nature of food packing, and determines the feasibility of the miniaturization of biotechnology plants. All these phenomena are based on the principle of bioadhesion. Bioadhesion is also the basis of the biomimetic material technologies, like the attachment of selected protein layers that can be used for nanomasking. (orig.)

  14. Steam sterilization does not require saturated steam

    NARCIS (Netherlands)

    van Doornmalen Gomez Hoyos, J. P.C.M.; Paunovic, A.; Kopinga, K.

    2017-01-01

    The most commonly applied method to sterilize re-usable medical devices in hospitals is steam sterilization. The essential conditions for steam sterilization are derived from sterilization in water. Microbiological experiments in aqueous solutions have been used to calculate various time–temperature

  15. Thermalizing Sterile Neutrino Dark Matter.

    Science.gov (United States)

    Hansen, Rasmus S L; Vogl, Stefan

    2017-12-22

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  16. Thermalizing Sterile Neutrino Dark Matter

    Science.gov (United States)

    Hansen, Rasmus S. L.; Vogl, Stefan

    2017-12-01

    Sterile neutrinos produced through oscillations are a well motivated dark matter candidate, but recent constraints from observations have ruled out most of the parameter space. We analyze the impact of new interactions on the evolution of keV sterile neutrino dark matter in the early Universe. Based on general considerations we find a mechanism which thermalizes the sterile neutrinos after an initial production by oscillations. The thermalization of sterile neutrinos is accompanied by dark entropy production which increases the yield of dark matter and leads to a lower characteristic momentum. This resolves the growing tensions with structure formation and x-ray observations and even revives simple nonresonant production as a viable way to produce sterile neutrino dark matter. We investigate the parameters required for the realization of the thermalization mechanism in a representative model and find that a simple estimate based on energy and entropy conservation describes the mechanism well.

  17. Effects of sterilization treatments on bulk and surface properties of nanocomposite biomaterials.

    Science.gov (United States)

    Ahmed, Maqsood; Punshon, Geoffrey; Darbyshire, Arnold; Seifalian, Alexander M

    2013-10-01

    With the continuous and expanding use of implantable biomaterials in a clinical setting, this study aims to elucidate the influence of sterilization techniques on the material surface and bulk properties of two polyurethane nanocomposite biomaterials. Both solid samples and porous membranes of nondegradable polyhedral oligomeric silsesquioxane poly(carbonate-urea) urethane (POSS-PCU) and a biodegradable poly(caprolactone-urea) urethane (POSS-PCL) were examined. Sterilization techniques included conventional steam sterilization (autoclaving), gamma irradiation, and disinfection via incubating with ethanol (EtOH) for 10 min or 24 h. After treatment, the samples were examined using gel permeation chromatography (GPC), attenuated total reflectance Fourier transform infrared spectroscopy, and tensiometry. Cytotoxicity was evaluated through the culture of endothelial progenitor cells and the efficacy of sterilization method was determined by incubating each sample in tryptone soya broth and fluid thioglycollate medium for cultivation of microorganisms. Although EtOH did not affect the material properties in any form, the samples were found to be nonsterile with microbial growth detected on each of the samples. Gamma irradiation was not only effective in sterilizing both POSS-PCU and POSS-PCL but also led to minor material degradation and displayed a cytotoxic effect on the cultured cells. Autoclaving was found to be the optimal sterilization technique for both solid and porous membranes of the nondegradable POSS-PCU samples as it was successful in sterilizing the samples, displayed no cytotoxic side effects and did not degrade the material. However, the biodegradable POSS-PCL was not able to withstand the harsh environment during autoclaving, resulting in it losing all structural integrity. Copyright © 2013 Wiley Periodicals, Inc., a Wiley Company.

  18. Sterile Endophthalmitis after Intravitreal Injections

    Directory of Open Access Journals (Sweden)

    Joaquín Marticorena

    2012-01-01

    Full Text Available Sterile endophthalmitis appears as an infrequent complication of intravitreal injections and seems to develop mainly in the context of the off-label use of drugs that have not been conceived for intravitreous administration. The aetiology of sterile endophthalmitis, independently of the administered drug, remains uncertain and a multifactorial origin cannot be discarded. Sterile inflammation secondary both to intravitreal triamcinolone acetonide and to intravitreal bevacizumab share many characteristics such as the acute and painless vision loss present in the big majority of the cases. Dense vitreous opacity is a common factor, while anterior segment inflammation appears to be mild to moderate. In eyes with sterile endophthalmitis, visual acuity improves progressively as the intraocular inflammation reduces without any specific treatment. If by any chance the ophthalmologist is not convinced by the sterile origin of the inflammation, this complication must be treated as an acute endophthalmitis because of the devastating visual prognosis of this intraocular infection in the absence of therapy.

  19. Comparison of steam sterilization conditions efficiency in the treatment of Infectious Health Care Waste.

    Science.gov (United States)

    Maamari, Olivia; Mouaffak, Lara; Kamel, Ramza; Brandam, Cedric; Lteif, Roger; Salameh, Dominique

    2016-03-01

    Many studies show that the treatment of Infectious Health Care Waste (IHCW) in steam sterilization devices at usual operating standards does not allow for proper treatment of Infectious Health Care Waste (IHCW). Including a grinding component before sterilization allows better waste sterilization, but any hard metal object in the waste can damage the shredder. The first objective of the study is to verify that efficient IHCW treatment can occur at standard operating parameters defined by the contact time-temperature couple in steam treatment systems without a pre-mixing/fragmenting or pre-shredding step. The second objective is to establish scientifically whether the standard operation conditions for a steam treatment system including a step of pre-mixing/fragmenting were sufficient to destroy the bacterial spores in IHCW known to be the most difficult to treat. Results show that for efficient sterilization of dialysis cartridges in a pilot 60L steam treatment system, the process would require more than 20 min at 144°C without a pre-mixing/fragmenting step. In a 720L steam treatment system including pre-mixing/fragmenting paddles, only 10 min at 144°C are required to sterilize IHCW proved to be sterilization challenges such as dialysis cartridges and diapers in normal conditions of rolling. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. 21 CFR 522.1862 - Sterile pralidoxime chloride.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sterile pralidoxime chloride. 522.1862 Section 522....1862 Sterile pralidoxime chloride. (a) Chemical name. 2-Formyl-1-methylpyridinium chloride oxime. (b) Specifications. Sterile pralidoxime chloride is packaged in vials. Each vial contains 1 gram of sterile...

  1. Seeking sterile neutrinos in Finslerian cosmology

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Deng [Nankai University, Theoretical Physics Division, Chern Institute of Mathematics, Tianjin (China); Meng, Xin-He [Nankai University, Department of Physics, Tianjin (China)

    2017-11-15

    For the first time, to search for sterile neutrinos in the framework of Finler geometry, we constrain four cosmological models using the most stringent constraint we can provide so far. We find that the Finslerian massless sterile neutrino model can, respectively, give a better cosmological fit to data and alleviate the current H{sub 0} tension more effectively than the other three models. For the Finslerian massless sterile neutrino model, we obtain the constraint N{sub eff} = 3.237{sup +0.092}{sub -0.185}, which is consistent with ΔN{sub eff} > 0 at the 1.03σ confidence level (CL). This gives a very weak hint of massless sterile neutrinos and may imply the non-existence of massless sterile neutrinos in the Finslerian cosmological setting. For the Finslerian massive sterile neutrino model, we obtain the constraints N{sub eff} = 3.143{sup +0.064}{sub -0.066}, which favors ΔN{sub eff} > 0 at the 1.47σ CL, and m{sub ν,sterile}{sup eff} < 0.121 eV at the 2σ CL which is much tighter than the Planck results. This very tight restriction appears to indicate the massive sterile neutrinos are also non-existent in the Finslerian scenarios. Consequently, one may conclude that the sterile neutrinos are possibly non-existent in the Finslerian universe. Our results are compatible with the recent results of the neutrino oscillation experiments implemented by the Daya Bay and MINOS collaborations and the cosmic ray one carried out by the IceCube collaboration. (orig.)

  2. Documentation requirements for radiation sterilization

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation for appr......Several standards are recently approved or are under development by the standard organizations ISO and CEN in the field of radiation sterilization. Particularly in Europe these standards define new requirements on some issues and on other issues they emphasize the necessary documentation...... for approval of radiation sterilized products. The impact of these standards on the radiation sterilization is discussed, with special attention given to a few special issues, mainly traceability and uncertainty of measurement results....

  3. Chilled packing systems for fruit flies (Diptera: Tephritidae) in the sterile insect technique

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Emilio; Escobar, Arseny; Bravo, Bigail; Montoya, Pablo [Instituto Interamericano de Cooperacion para la Agricultura (IICA), Chiapas (Mexico); Secretaria de Agricultura, Ganaderia, Desarrollo Rural, Pesca y Alimentacion (SAGARPA), Mexico, D.F. (Mexico). Programa Moscafrut

    2010-07-15

    We evaluated three packing systems (PARC boxes, 'GT' screen towers and 'MX' screen towers) for the emergence and sexual maturation of sterile fruit flies, at three adult fl y densities (1, 1.2 and 1.3 fly/cm 2) and three food types. At the lowest density, results showed no significant differences in the longevity and flight ability of adult Anastrepha ludens (Loew) and Anastrepha obliqua Macquart among the three packing systems. Higher densities resulted in a decrease in these parameters. In the evaluation of the three food types, no significant differences were found either on longevity or flight ability of A. ludens. However, the greatest longevity for both sexes A. obliqua was obtained with commercial powdered Mb and the mix of sugar, protein and corn starch on paper (SPCP) food types. The highest value for flight ability in A. obliqua males was obtained with powdered Mb and SPCP food types, and for females with Mb powdered food. Our data indicated that GT and MX screen tower packing systems are an alternative to the PARC boxes, since they were suitable for adult fl y sexual maturation without any harm to their longevity or flight ability. The tested foods were equivalent in both fruit fl y species, with the exception of the agar type for A. obliqua, which yielded the lowest biological parameters evaluated. Our results contribute to the application of new methods for the packing and release of sterile flies in large-scale programs. (author)

  4. Sterilization can change properties of bioceramics

    International Nuclear Information System (INIS)

    Willmann, G.

    2003-01-01

    Bioceramics made of bioinert alumina or zirconia and bioactive hydroxyapatite are well established implant materials. Implants have to be cleaned and sterilized. When sterilized some bioceramics change their color. This may effect their properties. No decrease of mechanical strength is observed when sterilizing alumina and the novel ceramic biocomposite AMC (Alumina Matrix Composite) with steam or Co 60 Gamma irradiation. When sterilizing Y-TZP zirconia with steam a decrease of strength is observed. (Abstract Copyright [2003], Wiley Periodicals, Inc.) [de

  5. Steam sterilization costs: a guide for the central service manager.

    Science.gov (United States)

    O'Shaughnessy, K L

    1993-07-01

    The Nassau County Medical Center CS department, East Meadow, New York, was faced with a staff layoff and an increased workload. With some hard thinking and strong staff support, new processes/systems were designed to save time and money. These included outsourcing the sterilization of "easy" trays, instituting a case cart program and developing custom packs. In order to determine where savings could be had, it was first important to examine current costs. By breaking the costs of sterilization processing down into an average cost per load, a formula was developed that helped determine many additional cost comparisons for the department. For example, the cost analysis formula could be used by CS departments to determine the cost-effectiveness of off-site sterilization, to compare using disposable vs. reusable items and to determine costs for EtO sterilization and aeration.

  6. International Standards for Radiation Sterilization of Medical Devices

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    For a terminally sterilized medical device to be designated '' STERILE '', probability of finding the viable micro-organisms in the device shall be equal to or less than 1 x 10 -6 (EN 556-1:2001: Sterilization of medical devices - Requirements for medical devices to be designated '' STERILE '' - Part 1: Requirements for terminally sterilized medical devices). Author presents the main legal aspects of the international standards for radiation sterilization of medical devices

  7. Birth planning and sterilization in China.

    Science.gov (United States)

    Short, S E; Linmao, M; Wentao, Y

    2000-11-01

    Sterilization is the most prevalent method of contraception in China. Approximately half of all women of reproductive age report that they or their husbands are sterilized. Using data from the China Health and Nutrition Survey we describe patterns of sterilization in eight Chinese provinces. With a discrete-time event history model we investigate the link between characteristics of local birth planning policy and the risk of sterilization. After controlling for parity, the risk of sterilization is highest in communities where birth planning policy is least strong as measured by exceptions to the one-child policy. These results suggest that couples with more flexibility in family building may have less control over contraceptive method use. Other factors affecting the risk of sterilization are a woman's age, parity, and whether or not she has a son. Our results emphasize the importance of taking into account multiple dimensions of reproductive behaviour when assessing one-child policy changes.

  8. Geographic Variation in Characteristics of Postpartum Women Using Female Sterilization.

    Science.gov (United States)

    White, Kari; Potter, Joseph E; Zite, Nikki

    2015-01-01

    Southern states have higher rates of female sterilization compared with other areas of the United States, and the reasons for this are not well understood. We examined whether low-income and racial/ethnic minority women, who were previous targets of coercive practices, disproportionately report using sterilization in the South. We used data from 12 states participating in the Pregnancy Risk Assessment Monitoring System that collected information on women's contraceptive method use between 2006 and 2009. We categorized states according to geographic region: South, Midwest/West, and Northeast. Within each region, we computed the percentage of women using sterilization according to their demographic and obstetric characteristics and estimated multivariable-adjusted prevalence ratios to evaluate whether the same characteristics were associated with sterilization use. The percentage of postpartum women using sterilization ranged from 5.0% to 9.9% in the Northeast, 8.9% to 10.6% in the Midwest/West, and 11.6% to 22.4% in the South. Women in nearly all subgroups in Southern states were more likely to use sterilization than women in the Northeast. After multivariable adjustment, there were no differences in the prevalence of sterilization for Blacks compared with Whites in the Northeast (0.76; 95% CI, 0.55-1.06), Midwest/West (0.91; 95% CI, 0.80-1.04), and South (0.96; 95% CI, 0.85-1.07). Women with Medicaid-paid deliveries (vs. private insurance) had a higher prevalence of sterilization in all regions (p sterilization at disproportionately higher rates compared with other regions, and suggest that other differences, such as social norms and family planning policies, may contribute to this geographic variation. Copyright © 2015 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  9. The male gametophytic sterility. 1 - Gametic sterilities and deletions in petunia

    International Nuclear Information System (INIS)

    Cornu, A.; Maizonnier, D.

    1982-01-01

    Terminal deletions induced by ionizing radiations in Petunia are not sexually transmitted. Cytogenetic study of plants with a heterozygous deletion and their progenies shows that this lack of transmission is accompanied by a gametic semi-sterility due to the fact that gametes carrying the deleted chromosome are not viable. The interest of such a male sterility with a gametophytic determinism for the study of sporophyte-gametophyte relationships is underlined [fr

  10. Radiosterilization or sterilization by steam. Procedures for sterilization of spices

    International Nuclear Information System (INIS)

    Warmbold, J.

    1994-01-01

    The article compares two different methods for the sterilization of spices, namely radiosterilization and sterilization with steam. The first method applies ionizing radiation which can alter the chemical composition of the products. Tests have shown, however, that radiation doses up to 10 kGy will not induce the formation of carcinogenic agents in the foodstuffs, or of toxic substances, and thus are a wholesome method of preservation. Any modifications of taste, color or smell, or loss of vitamins, can be avoided by proper dose control and standard irradiation conditions. Sterilization by steam is a method achieving substantial suppression of the formation of germs, aerobic spores, yeasts, mould, and gramnegative germs, while preserving in most cases the essential oils. It may result in sensoric alterations, i.e affect the color, smell or taste, but in general the spices thus treated preserved their characteristic properties. The method is a good alternative to radiosterilization. The article adds some concluding information on mandatory labelling of irradiated food imported from third countries

  11. A preliminary evaluation of a reusable digital sterilization indicator prototype.

    Science.gov (United States)

    Puttaiah, R; Griggs, J; D'Onofrio, M

    2014-09-01

    in an autoclave. In this study, the final batch of the DS1922F prototype data logger was found to be robust in withstanding the challenge of 600 autoclave cycles, with a mean lifetime of more than 450 cycles, multiple times more than prescribed number of cycles. Instrument reprocessing is among the important aspects of infection control. While stringent procedures are followed in instrument reprocessing within the clinic in assuring patient safety, regular use of sterilization process indicators and periodic biological validation of the sterilizer's performance is necessary. Chemical indicators for use in Autoclaves provide information on whether the particular cycle's parameters were achieved but do not provide at what specific point in time or temperature the failure occurred. Data loggers and associated reader software as the tested prototype in this evaluation (DS1922F), are designed to provide continuous information on time and temperature of the prescribed cycle. Data loggers provide immediate information on the process as opposed to Biological Indicators that take from days to a week in obtaining a confirmatory result. Further, many countries do not have the sterilization monitoring service infrastructure to meet the demands of the end users. In the absence of sterilization monitoring services, use of digital data loggers for each sterilization cycle is more pragmatic.

  12. Risk analysis of sterile production plants: a new and simple, workable approach.

    Science.gov (United States)

    Gapp, Guenther; Holzknecht, Peter

    2011-01-01

    A sterile active ingredient plant and a sterile finished dosage filling plant both comprise very complex production processes and systems. The sterility of the final product cannot be assured solely by sterility testing, in-process controls, environmental monitoring of cleanrooms, and media fill validations. Based on more than 15 years experience, 4 years ago the authors created a new but very simple approach to the risk analysis of sterile plants. This approach is not a failure mode and effects analysis and therefore differs from the PDA Technical Report 44 Quality Risk Management for Aseptic Processes of 2008. The principle involves specific questions, which have been defined in the risk analysis questionnaire in advance, to be answered by an expert team. If the questionnaire item is dealt with appropriately, the answer is assigned a low-risk number (1) and if very weak or deficient it gets a high-risk number (5). In addition to the numbers, colors from green (not problematic) through orange to red (very problematic) are attributed to make the results more striking. Because the individual units of each production plant have a defined and different impact on the overall sterility of the final product, different risk emphasis factors have to be taken into account (impact factor 1, 3, or 5). In a well run cleanroom, the cleanroom operators have a lower impact than other units with regard to the contamination risk. The resulting number of the analyzed production plant and the diagram of the assessment subsequently offers very important and valuable information about a) the risk for microbiological contamination (sterility/endotoxins) of the product, and b) the compliance status of the production plant and the risk of failing lots, as well as probable observations of upcoming regulatory agency audits. Both items above are highly important for the safety of the patient. It is also an ideal tool to identify deficient or weak systems requiring improvement and upgrade

  13. [Legal statutes on sterilization].

    Science.gov (United States)

    Zupancic, K

    1980-01-01

    Sterilization in Yugoslavia is no population policy measure. Decision about the birth of children is free, a private problem of any individual, a basic right guaranteed by the Constitution. However, according to certain laws in Slovenia and Croatia, sterilization is allowed as a family planning method in persons over 35 year old. Only exceptionally can sterilization be applied in persons younger than 35 years: according to the Slovenian law, in cases when a person lacks the capacity of reasoning and also when there are medical indications, and according to the Croatian law, when there are medical and eugenic reasons (if the child is supposed to be born with negative congenital properties).

  14. Genetic basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Robinson, A.S.

    2014-01-01

    The use of the sterile insect technique for insect control relies on the introduction of sterility in the females of the wild population. This sterility is produced following the mating of these females with released males carrying, in their sperm, dominant lethal mutations that have been induced by ionizing radiation. As well as radiation-induced sterility, natural mechanisms can be recruited, especially the use of hybrid sterility. Radiation is usually one of the last procedures that insects undergo before leaving mass-rearing facilities for release in the field. It is essential that the dosimetry of the radiation source be checked to ensure that all the insects receive the required minimum dose. A dose should be chosen that maximizes the level of introduced sterility in the wild females in the field. Irradiation in nitrogen can provide protection against the detrimental somatic effects of radiation. Currently, the development of molecular methods to sterilize pest insects in the field, by the release of fertile insects carrying trans genes, is very much in vogue. It is concluded that using a physical process, such as radiation, will always have significant advantages over genetic and other methods of sterilization for the large-scale application of the sterile insect technique. (author)

  15. Electron sterilization validation techniques using the controlled depth of sterilization process

    International Nuclear Information System (INIS)

    Cleghorn, D.A.; Nablo, S.V.

    1990-01-01

    Many pharmaceutical products, especially parenteral drugs, cannot be sterilized with gamma rays or high energy electrons due to the concomitant product degradation. In view of the well-controlled electron energy spectrum available in modern electron processors, it is practical to deliver sterilizing doses over depths considerably less than those defining the thickness of blister-pack constructions or pharmaceutical containers. Because bremsstrahlung and X-ray production are minimized at these low electron energies and in these low Z materials, very high electron: penetrating X-ray dose ratios are possible for the application of the technique. Thin film dosimetric techniques have been developed utilizing radiochromic film in the 10-60 g/m 2 range for determining the surface dose distribution in occluded surface areas where direct electron illumination is not possible. Procedures for validation of the process using dried spore inoculum on the product as well as in good geometry are employed to determine the process lethality and its dependence on product surface geometry. Applications of the process to labile pharmaceuticals in glass and polystyrene syringes are reviewed. It has been applied to the sterilization of commercial sterile products since 1987, and the advantages and the natural limitations of the technique are discussed. (author)

  16. PDCA循环在消毒供应中心质量持续改进中的应用%Application of PDCA cycle in continuous quality improvement of central sterile supply department

    Institute of Scientific and Technical Information of China (English)

    陈洁; 李淑君; 李燕妮; 秦建; 翟智超; 董海蛟; 王聪

    2013-01-01

    OBJECTIVE To explore the application of PDCA cycle management mode in continuous quality improvement of the central sterile supply department and further strengthen the central sterile supply quality management so as to ensure zero defect of the sterile supplies.METHODS The quality control management team was established,the PDCA cycle management responsibility system was implemented,the PDCA cycle management approach was employed to set up the key points of the quality control,the PDCA cycle improvement program was developed to constantly improve the systems; the PDCA group was implemented the PDCA cycle management mode in Nov 2011,while the control group was not implemented the PDCA cycle management mode from Nov 2010 to Oct 2011,there were 96 pieces of data in each group,then the satisfaction rate was compared between the two groups.RESULTS After the implementation of the PDCA cycle management mode,the satisfaction rate of the clinical departments was 97.9% in the PDCA group,significantly higher than 91.7% of the control group,the difference was significant(P<0.05); the qualified rates of the hand hinge,monitoring of disinfectant concentration,cleaning and disinfection of surgical equipments,cleaning and disinfection of pipelines,rust removal,sterile supplies of the PDCA group were respectively 99.0%,95.5%,98.0%,97.5%,97.0%,and 100.0%,significantly higher than those of the control group (P<0.05).CONCLUSION Through the application of PDCA cycle management model and the implementation of comprehensively continuous quality improvement,the overall quality of the CSSD staff,service quality,and quality of the sterile supplies have been substantially improved.%目的 探索PDCA循环管理模式在消毒供应中心(CSSD)质量持续改进中的应用,进一步加强CSSD质量管理,保证无菌物品供应零缺陷.方法

  17. Probabilistic model for sterilization of food

    International Nuclear Information System (INIS)

    Chepurko, V.V.; Malinovskij, O.V.

    1986-01-01

    The probabilistic model for radiation sterilization is proposed based on the followng suppositions: (1) initial contamination of a volume unit of the sterilized product m is described by the distribution of the probabilities q(m), (2) inactivation of the population from m of microorganisms is approximated by Bernoulli test scheme, and (3) contamination of unit of the sterilized product is independent. The possibility of approximation q(m) by Poisson distribution is demonstrated. The diagrams are presented permitting to evaluate the dose which provides the defined reliability of sterilization of food for chicken-gnotobionts

  18. Acute sterile endophthalmitis following intravitreal bevacizumab: case series

    Science.gov (United States)

    Orozco-Hernández, Axel; Ortega-Larrocea, Ximena; Sánchez-Bermúdez, Gustavo; García-Aguirre, Gerardo; Cantón, Virgilio Morales; Velez-Montoya, Raul

    2014-01-01

    Background Since the ophthalmological community adopted the use of intravitreal bevacizumab as an accepted off-label treatment for neovascular diseases, the amount of knowledge regarding its effects and properties has been increasing continually. In the last few years, there have been an increasing number of reports about sterile intraocular inflammation and intraocular pressure elevations after intravitreal bevacizumab. In the following case series, we describe the clinical presentation and outcomes of ten consecutive cases of patients developing mild-to-severe sterile intraocular inflammation after intravitreal bevacizumab and their management. Methods This report presents a retrospective case series. We reviewed the medical records of ten consecutive patients from a group of 46, in whom repackaged bevacizumab in individual aliquots from two vials from the same batch were used. All surgical procedures were performed using standard sterile techniques in the operating room. At each follow-up visit, patients underwent a complete ophthalmological examination including visual acuity assessment, intraocular pressure, biomicroscopy, and posterior fundus examination. Results Ten patients presented sterile endophthalmitis with an onset time of 3.5±1.95 days. The clinical characteristics were mild pain, slight visual loss, conjunctival hyperemia, and various degrees of intraocular inflammation with microhypopyon. All cultures were negative. All patients were managed with topical steroids and antibiotics, except two, in whom, due to severe vitreous cells, intravitreal antibiotics were used. Three patients showed a transient elevation of intraocular pressure. Only 50% of the patients regained a visual acuity equal or better to the baseline visual acuity on file. Conclusion The increasing number of intravitreal injections of bevacizumab applied every day, due to its widespread acceptance, might be one reason why the number of cases of sterile endophthalmitis is rising. Fast

  19. Voluntary sterilization in Serbia: Unmet need?

    Directory of Open Access Journals (Sweden)

    Rašević Mirjana M.

    2002-01-01

    Full Text Available Is voluntary sterilization as a birth control method accepted in Serbia? This is certainly a question that is being imposed for research, regardless of the fact that voluntary sterilization is neither accessible nor promoted. Most importantly because there is no understanding in the social nor political sphere for legalization of voluntary sterilization as a form of birth control, apart from the clear necessity for this, first, step. They are: the recognition that voluntary sterilization is an efficient and safe birth control method, respectability of basic human as well as sexual and reproductive rights, spreading of sterilization as a form of birth control among population of both developed and developing countries and an epidemic diffusion of repeated induced abortions in Serbia. Thus individual recognition of the advantages of relying on voluntary sterilization, in a non-encouraging atmosphere, certainly represents one more argument to enable couples to prevent conception by sterilization. Since it was impossible to carry out a representative research among the population of men and women who are at risk for conception, an attempt was made to obtain a reply to the set question among women who decided to induce abortion. It was done out of at least two reasons. The first being that women with induced abortion in their reproductive history were the target group for voluntary sterilization. The second reason was based on the assumption that bringing a decision on induced abortion is preceded by the reconsideration of an earlier adopted strategy regarding children, giving birth and contraception and thus its rational component is revealed more and therefore more easily measurable. The research was carried out in the University Clinic of Obstetrics and Gynecology 'Narodni front' in Belgrade from January 21st o March 1st 2002, and included 296 women. By comparing the social and demographic characteristics of the female respondents, as well as

  20. Sterility induction in tsetse

    Energy Technology Data Exchange (ETDEWEB)

    Curtis, C F [London School of Hygiene and Tropical Medicine (UK); Langley, P A [Bristol Univ. (UK)

    1982-01-01

    The first laboratory and field experiments on genetic control were with tsetse flies, and they made use of the sterility in crosses and hybrids between closely related species of the Glossina morsitans complex. Backcrosses indicate that there are two separate sterility mechanisms involved: (a) genetic incompatibility between a mother and the products of alien genes in the embryo or larva in the uterus; (b) inability of hybrid males to inseminate due to incompatibility of their X-chromosomes with an alien Y or autosomes. The two largest sterile male release programmes have been in Tanzania and Upper Volta, and have used irradiation at the pupal or adult stage, respectively, for the production of sterility. Male tsetse are remarkably resistant to radiosterilization and, with the doses required to induce dominant lethals in more than 95% of sperms, premature senescence and lethargic behaviour of the males tends to result. With G. morsitans irradiated at the puparial stage these effects can be alleviated by the use of a nitrogen atmosphere during irradiation. If the puparia are then transferred to air at 11/sup 0/C for transport to the release site, immediate emergence occurs on re-warming after arrival. This advantageous procedure was used for the releases in Tanzania. In addition to dominant lethals, irradiation also produces chromosome translocations which cause inherited partial sterility. A homozygous translocation line was selected but this example did not have sufficient fitness to be used in a mass rearing programme. Chemosterilants can be applied by pupal dipping, adult contact with deposits or in aerosols. Studies are now in progress on their use in association with odour-baited traps or pheromone-baited decoys as a means of sterilizing the wild population and thus avoiding the costly and difficult process of mass rearing tsetse.

  1. Modular ionizing sterilizer (MIS)

    International Nuclear Information System (INIS)

    Freijo, Jose L.

    1999-01-01

    A transportable device designed to sterilize medical material and wastes by gamma irradiation is described. The sterilizer is formed by three modules: one of the modules contains the gamma source and can be removed to transport and transfer the source, the other modules are designed to introduce and draw out the materials to be irradiated

  2. Early events in speciation: polymorphism for hybrid male sterility in Drosophila.

    Science.gov (United States)

    Reed, Laura K; Markow, Therese A

    2004-06-15

    Capturing the process of speciation early enough to determine the initial genetic causes of reproductive isolation remains a major challenge in evolutionary biology. We have found, to our knowledge, the first example of substantial intraspecific polymorphism for genetic factors contributing to hybrid male sterility. Specifically, we show that the occurrence of hybrid male sterility in crosses between Drosophila mojavensis and its sister species, Drosophila arizonae, is controlled by factors present at different frequencies in different populations of D. mojavensis. In addition, we show that hybrid male sterility is a complex phenotype; some hybrid males with motile sperm still cannot sire offspring. Because male sterility factors in hybrids between these species are not yet fixed within D. mojavensis, this system provides an invaluable opportunity to characterize the genetics of reproductive isolation at an early stage.

  3. The effect of methyl eugenol exposure on subsequent mating performance of sterile males of the oriental fruit fly, Bactrocera dorsalis

    International Nuclear Information System (INIS)

    Ji Qing'e; Guo Qingliang; Chen Jiahua

    2011-01-01

    The effect of methyl eugenol (ME) on the total times of mating, consecutive mating, mating competitiveness, multiple mating, and the incidence of wild female remating were studied in sterile males from a genetic sexing strain of Bactrocera dorsalis (Hendel). Male pupae were irradiated at dose of 100 Gy by 137 Cs at 2 d before emergence and the dose rate was 1.00 Gy/min. Sexually mature 10 day old sterile males were fed ME, while Non-ME-fed sterile males and normal wild males were used as control, and wild females as mating partners. The results showed that some ME-fed sterile males could mate continuously up to nine times, but the total times of consecutive mating and the mean value of continuous mating times were not significant (P > 0.05) compared with the control. The total mating times of ME-fed sterile males was 344.33 ± 12.55 and the mean value was 6.88 ± 0.25, but both have no significant difference compared with the control. The mating success rate of ME-fed and non-ME-fed sterile males mated with wild females were 44.67 ± 2.40% and 22.00 ± 2.31% separately. There were significant differences between them (t = -6.8, P = 0.002). The outcomes were that feeding on ME did not increase the frequency of multiple mating by sterile males, but significantly increased the mating competitiveness of sterile males against wild males. At the same time, sterile males fed ME did not significantly affect the remating of wild females 5 days after the initial mating, but increased the remating frequency of females 10 and 15 days after the initial mating. (authors)

  4. The effect of methyl eugenol exposure on subsequent mating performance of sterile males of the oriental fruit fly, bactrocera dorsalis

    International Nuclear Information System (INIS)

    Ji Qing'e; Guo Qingliang; Chen Jiaye

    2012-01-01

    The effect of methyl eugenol (ME) on the total times of mating, consecutive mating, mating competitiveness, multiple mating, and the incidence of wild female remating were studied in sterile males from a genetic sexing strain of Bactrocera dorsalis (Hendel). Male pupae were irradiated at dose of 100 Gy by 137 Cs at 2 d before emergence and the dose rate was 1.00 Gy/min. Sexually mature 10 day old sterile males were fed ME, while Non-ME-fed sterile males and normal wild males were used as control, and wild females as mating partners. The results showed that some ME-fed sterile males could mate continuously up to nine times, but the total times of consecutive mating and the mean value of continuous mating times were not significant (P> 0.05) compared with the control. The total mating times of ME-fed sterile males was 344.33±12.55 and the mean value was 6.88±0.25, but both have no significant difference compared with the control. The mating success rate of ME-fed and non- ME-fed sterile males mated with wild females were (44.67±2.40)% and (22.00±2.31)% separately. There were significant differences between them (t = -6.8, P = 0.002). The outcomes were that feeding on ME did not increase the frequency of multiple mating by sterile males, but significantly increased the mating competitiveness of sterile males against wild males. At the same time, sterile males fed ME did not significantly affect the remating of wild females 5 days after the initial mating, but increased the remating frequency of females 10 and 15 days after the initial mating. (authors)

  5. Device and Container for Reheating and Sterilization

    Science.gov (United States)

    Sastry, Sudhir K.; Heskitt, Brian F.; Jun, Soojin; Marcy, Joseph E.; Mahna, Ritesh

    2012-01-01

    Long-duration space missions require the development of improved foods and novel packages that do not represent a significant disposal issue. In addition, it would also be desirable if rapid heating technologies could be used on Earth as well, to improve food quality during a sterilization process. For this purpose, a package equipped with electrodes was developed that will enable rapid reheating of contents via ohmic heating to serving temperature during space vehicle transit. Further, the package is designed with a resealing feature, which enables the package, once used, to contain and sterilize waste, including human waste for storage prior to jettison during a long-duration mission. Ohmic heating is a technology that has been investigated on and off for over a century. Literature indicates that foods processed by ohmic heating are of superior quality to their conventionally processed counterparts. This is due to the speed and uniformity of ohmic heating, which minimizes exposure of sensitive materials to high temperatures. In principle, the material may be heated rapidly to sterilization conditions, cooled rapidly, and stored. The ohmic heating device herein is incorporated within a package. While this by itself is not novel, a reusable feature also was developed with the intent that waste may be stored and re-sterilized within the packages. These would then serve a useful function after their use in food processing and storage. The enclosure should be designed to minimize mass (and for NASA's purposes, Equivalent System Mass, or ESM), while enabling the sterilization function. It should also be electrically insulating. For this reason, Ultem high-strength, machinable electrical insulator was used.

  6. Biological basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Lance, D.R.; McInnis, D.O.

    2005-01-01

    In principle, the sterile insect technique (SIT) is applicable to controlling a wide variety of insect pests, but biological factors, interacting with socio-economic and political forces, restrict its practical use to a narrower set of pest species and situations. This chapter reviews how the biology and ecology of a given pest affect the feasibility and logistics of developing and using the SIT against that pest insect. The subjects of pest abundance, distribution, and population dynamics are discussed in relation to producing and delivering sufficient sterile insects to control target populations. Pest movement and distribution are considered as factors that influence the feasibility and design of SIT projects, including the need for population- or area-wide management approaches. Biological characteristics, that affect the ability of sterile insects to interact with wild populations, are presented, including the nature of mating systems of pests, behavioural and physiological consequences of mass production and sterilization, and mechanisms that males use to block a female's acquisition and/or use of sperm from other males. An adequate knowledge of the biology of the pest species and potential target populations is needed, both for making sound decisions on whether integration of the SIT into an area-wide integrated pest management (AW-IPM) programme is appropriate, and for the efficient and effective application of the technique. (author)

  7. Dynamic sterilization of titanium implants with ultraviolet light

    International Nuclear Information System (INIS)

    Singh, S.; Schaaf, N.G.

    1989-01-01

    All implantable devices must be sterile. However, autoclaves produce poor surface properties that jeopardize the integration process. The application of a modified ultraviolet light source has proven to enhance bioreactivity by controlling surface properties, but it lacks validation of its sterilization capabilities. Forty-eight titanium implants were contaminated with spores of the biological indicator Bacillus stearothermophilus and subjected to dynamic sterilization by ultraviolet light. Forty-seven of the implants were successfully sterilized, as indicated by not producing turbidity in a suitable growth medium. This sterilization technique only requires a 20-second exposure to achieve sterility

  8. Sterile neutrino dark matter with supersymmetry

    Science.gov (United States)

    Shakya, Bibhushan; Wells, James D.

    2017-08-01

    Sterile neutrino dark matter, a popular alternative to the WIMP paradigm, has generally been studied in non-supersymmetric setups. If the underlying theory is supersymmetric, we find that several interesting and novel dark matter features can arise. In particular, in scenarios of freeze-in production of sterile neutrino dark matter, its superpartner, the sterile sneutrino, can play a crucial role in early Universe cosmology as the dominant source of cold, warm, or hot dark matter, or of a subdominant relativistic population of sterile neutrinos that can contribute to the effective number of relativistic degrees of freedom Neff during big bang nucleosynthesis.

  9. Genetic complexity underlying hybrid male sterility in Drosophila.

    Science.gov (United States)

    Sawamura, Kyoichi; Roote, John; Wu, Chung-I; Yamamoto, Masa-Toshi

    2004-02-01

    Recent genetic analyses of closely related species of Drosophila have indicated that hybrid male sterility is the consequence of highly complex synergistic effects among multiple genes, both conspecific and heterospecific. On the contrary, much evidence suggests the presence of major genes causing hybrid female sterility and inviability in the less-related species, D. melanogaster and D. simulans. Does this contrast reflect the genetic distance between species? Or, generally, is the genetic basis of hybrid male sterility more complex than that of hybrid female sterility and inviability? To clarify this point, the D. simulans introgression of the cytological region 34D-36A to the D. melanogaster genome, which causes recessive male sterility, was dissected by recombination, deficiency, and complementation mapping. The 450-kb region between two genes, Suppressor of Hairless and snail, exhibited a strong effect on the sterility. Males are (semi-)sterile if this region of the introgression is made homozygous or hemizygous. But no genes in the region singly cause the sterility; this region has at least two genes, which in combination result in male sterility. Further, the males are less fertile when heterozygous with a larger introgression, which suggests that dominant modifiers enhance the effects of recessive genes of male sterility. Such an epistatic view, even in the less-related species, suggests that the genetic complexity is special to hybrid male sterility.

  10. Inheritance of sterility in Dysdercus koenigii F. (Hemiptera: Pyrrhocoridae)

    International Nuclear Information System (INIS)

    Harwalkar, M.R.; Rahalkar, G.W.

    1979-01-01

    It has been suggested that for the control of Lepidopterous populations, release of fully competitive partially sterile males would be more advantageous than the release of completely sterile males. This suggestion is based on the fact, elucidated in many studies, that partially sterilized males mated to normal females produce totally sterile or partially sterile progeny. In Hemiptera too, F 1 progeny of partially sterile males has been shown to inherit sterility. Individual impact of sterility inherited by either sex of the F 1 progeny on population growth has been studied in an hemipteran insect Dysdercus koenigii. A dose of 7 krad induces near-complete sterility in males. When males irradiated with substerilizing doses of 1,2 and 3 krad were crossed with normal females, F 1 progeny of both sexes was partially sterile : the female being more sterile than the males. When the F 1 progeny was intercrossed, there was enhanced reduction in progeny production. (auth.)

  11. Electrolytic silver ion cell sterilizes water supply

    Science.gov (United States)

    Albright, C. F.; Gillerman, J. B.

    1968-01-01

    Electrolytic water sterilizer controls microbial contamination in manned spacecraft. Individual sterilizer cells are self-contained and require no external power or control. The sterilizer generates silver ions which do not impart an unpleasant taste to water.

  12. Segregation of male-sterility alleles across a species boundary.

    Science.gov (United States)

    Weller, S G; Sakai, A K; Culley, T M; Duong, L; Danielson, R E

    2014-02-01

    Hybrid zones may serve as bridges permitting gene flow between species, including alleles influencing the evolution of breeding systems. Using greenhouse crosses, we assessed the likelihood that a hybrid zone could serve as a conduit for transfer of nuclear male-sterility alleles between a gynodioecious species and a hermaphroditic species with very rare females in some populations. Segregation patterns in progeny of crosses between rare females of hermaphroditic Schiedea menziesii and hermaphroditic plants of gynodioecious Schiedea salicaria heterozygous at the male-sterility locus, and between female S. salicaria and hermaphroditic plants from the hybrid zone, were used to determine whether male-sterility was controlled at the same locus in the parental species and the hybrid zone. Segregations of females and hermaphrodites in approximately equal ratios from many of the crosses indicate that the same nuclear male-sterility allele occurs in the parent species and the hybrid zone. These rare male-sterility alleles in S. menziesii may result from gene flow from S. salicaria through the hybrid zone, presumably facilitated by wind pollination in S. salicaria. Alternatively, rare male-sterility alleles might result from a reversal from gynodioecy to hermaphroditism in S. menziesii, or possibly de novo evolution of male sterility. Phylogenetic analysis indicates that some species of Schiedea have probably evolved separate sexes independently, but not in the lineage containing S. salicaria and S. menziesii. High levels of selfing and expression of strong inbreeding depression in S. menziesii, which together should favour females in populations, argue against a reversal from gynodioecy to hermaphroditism in S. menziesii. © 2014 The Authors. Journal of Evolutionary Biology © 2014 European Society For Evolutionary Biology.

  13. Genetic analysis of male sterility genes in different A and B sorghum ...

    African Journals Online (AJOL)

    Hybrid seed production requires use of cytoplasmic male sterility (CMS). Without this system, hybrid seed production would not be economically feasible. There is, therefore, need for developing A and B sorghum lines, as an essential step for development of hybrid sorghum industry. A genetic study of male sterility in ...

  14. Radiation sterilization of skin allograft

    International Nuclear Information System (INIS)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-01-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6 . The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2 . The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  15. Radiation sterilization of skin allograft

    Science.gov (United States)

    Kairiyama, E.; Horak, C.; Spinosa, M.; Pachado, J.; Schwint, O.

    2009-07-01

    In the treatment of burns or accidental loss of skin, cadaveric skin allografts provide an alternative to temporarily cover a wounded area. The skin bank facility is indispensable for burn care. The first human skin bank was established in Argentina in 1989; later, 3 more banks were established. A careful donor selection is carried out according to the national regulation in order to prevent transmissible diseases. As cadaveric human skin is naturally highly contaminated, a final sterilization is necessary to reach a sterility assurance level (SAL) of 10 -6. The sterilization dose for 106 batches of processed human skin was determined on the basis of the Code of Practice for the Radiation Sterilization of Tissue Allografts: Requirements for Validation and Routine Control (2004) and ISO 11137-2 (2006). They ranged from 17.6 to 33.4 kGy for bioburdens of >10-162.700 CFU/100 cm 2. The presence of Gram negative bacteria was checked for each produced batch. From the analysis of the experimental results, it was observed that the bioburden range was very wide and consequently the estimated sterilization doses too. If this is the case, the determination of a tissue-specific dose per production batch is necessary to achieve a specified requirement of SAL. Otherwise if the dose of 25 kGy is preselected, a standardized method for substantiation of this dose should be done to confirm the radiation sterilization process.

  16. The pachytene checkpoint and its relationship to evolutionary patterns of polyploidization and hybrid sterility.

    Science.gov (United States)

    Li, X C; Barringer, B C; Barbash, D A

    2009-01-01

    Sterility is a commonly observed phenotype in interspecific hybrids. Sterility may result from chromosomal or genic incompatibilities, and much progress has been made toward understanding the genetic basis of hybrid sterility in various taxa. The underlying mechanisms causing hybrid sterility, however, are less well known. The pachytene checkpoint is a meiotic surveillance system that many organisms use to detect aberrant meiotic products, in order to prevent the production of defective gametes. We suggest that activation of the pachytene checkpoint may be an important mechanism contributing to two types of hybrid sterility. First, the pachytene checkpoint may form the mechanistic basis of some gene-based hybrid sterility phenotypes. Second, the pachytene checkpoint may be an important mechanism that mediates chromosomal-based hybrid sterility phenotypes involving gametes with non-haploid (either non-reduced or aneuploid) chromosome sets. Studies in several species suggest that the strength of the pachytene checkpoint is sexually dimorphic, observations that warrant future investigation into whether such variation may contribute to differences in patterns of sterility between male and female interspecific hybrids. In addition, plants seem to lack the pachytene checkpoint, which correlates with increased production of unreduced gametes and a higher incidence of polyploid species in plants versus animals. Although the pachytene checkpoint occurs in many animals and in fungi, at least some of the genes that execute the pachytene checkpoint are different among organisms. This finding suggests that the penetrance of the pachytene checkpoint, and even its presence or absence can evolve rapidly. The surprising degree of evolutionary flexibility in this meiotic surveillance system may contribute to the observed variation in patterns of hybrid sterility and in rates of polyploidization.

  17. A Novel Technique for Sterilization Using a Power Self-Regulated Single-Mode Microwave Cavity.

    Science.gov (United States)

    Reverte-Ors, Juan D; Pedreño-Molina, Juan L; Fernández, Pablo S; Lozano-Guerrero, Antonio J; Periago, Paula M; Díaz-Morcillo, Alejandro

    2017-06-07

    In this paper, a novel technique to achieve precise temperatures in food sterilization has been proposed. An accurate temperature profile is needed in order to reach a commitment between the total removal of pathogens inside the product and the preservation of nutritional and organoleptic characteristics. The minimal variation of the target temperature in the sample by means of a monitoring and control software platform, allowing temperature stabilization over 100 °C, is the main goal of this work. A cylindrical microwave oven, under pressure conditions and continuous control of the microwave supply power as function of the final temperature inside the sample, has been designed and developed with conditions of single-mode resonance. The uniform heating in the product is achieved by means of sample movement and the self-regulated power control using the measured temperature. Finally, for testing the sterilization of food with this technology, specific biological validation based on Bacillus cereus as a biosensor of heat inactivation has been incorporated as a distribution along the sample in the experimental process to measure the colony-forming units (CFUs) for different food samples (laboratory medium, soup, or fish-based animal by-products). The obtained results allow the validation of this new technology for food sterilization with precise control of the microwave system to ensure the uniform elimination of pathogens using high temperatures.

  18. A Novel Technique for Sterilization Using a Power Self-Regulated Single-Mode Microwave Cavity

    Directory of Open Access Journals (Sweden)

    Juan D. Reverte-Ors

    2017-06-01

    Full Text Available In this paper, a novel technique to achieve precise temperatures in food sterilization has been proposed. An accurate temperature profile is needed in order to reach a commitment between the total removal of pathogens inside the product and the preservation of nutritional and organoleptic characteristics. The minimal variation of the target temperature in the sample by means of a monitoring and control software platform, allowing temperature stabilization over 100 °C, is the main goal of this work. A cylindrical microwave oven, under pressure conditions and continuous control of the microwave supply power as function of the final temperature inside the sample, has been designed and developed with conditions of single-mode resonance. The uniform heating in the product is achieved by means of sample movement and the self-regulated power control using the measured temperature. Finally, for testing the sterilization of food with this technology, specific biological validation based on Bacillus cereus as a biosensor of heat inactivation has been incorporated as a distribution along the sample in the experimental process to measure the colony-forming units (CFUs for different food samples (laboratory medium, soup, or fish-based animal by-products. The obtained results allow the validation of this new technology for food sterilization with precise control of the microwave system to ensure the uniform elimination of pathogens using high temperatures.

  19. Why are rates of sterilization in decline? A pilot study designed to explore reasons for declining female sterilization in Scotland.

    Science.gov (United States)

    Chen, Zhong E; Glasier, Anna; Warner, Pamela

    2008-10-01

    In the last decade, female sterilization had been in decline throughout the UK. It is not clear whether fewer women are requesting sterilization or whether the universal enthusiasm for long-acting reversible methods is leading health professionals to discourage women from being sterilized. Since correct and consistent use of alternative, reversible contraceptive methods depends somewhat on their acceptability, it is important to determine whether women are being refused sterilization or whether they are freely choosing other methods. This study aims to explore whether female sterilization is being widely considered as a contraceptive method, the reasons for choosing or rejecting it, and whether women are being discouraged by health professionals from being sterilized. A self-completed questionnaire survey among 205 women aged 30 to 50 years who felt that their family was complete attending a family planning clinic in Scotland. Of the 203 women included in the study, 151 (74.4%) had heard of female sterilization, 90 had discussed it with someone (60%) and 87 (58%) had considered it as a contraceptive option. Of the 56 women who consulted their family doctor about sterilization, almost half (27; 48%) were not referred to a hospital and fewer than one (17, 30.4%) in three of them was eventually sterilized or had arrangements in place to get it done. Free-text comments from the women revealed a variety of reasons for not choosing female sterilization and suggested that some women are being deterred from sterilization. The study suggests that some women are being actively encouraged by health professionals to use long-acting reversible contraceptive methods and discouraged from choosing sterilization. However, other women recognize for themselves the wisdom of keeping their fertility options open.

  20. Sterilization of instruments in solar ovens

    Energy Technology Data Exchange (ETDEWEB)

    Fjendbo Joergensen, A. [Odense Univ. Hospital, Dept. of Infectious Diseases, Odense (Denmark); Noehr, K. [Odense Technical College, Dept. of Metal, Odense (Denmark); Boisen, F. [The Danish Veterinary and Food Administration Funen, Dept. of Microbiology, Odense (Denmark)

    2000-07-01

    The sterilization of instruments in rural health clinics in less developed countries is an increasing problem because chemical methods can no longer be recommended and wood fuel is becoming more and more scarce. Thus, it seemed obvious to try to utilize solar energy for sterilization purposes. A solar oven was designed and manufactured using local materials and simple tools. The solar oven was tested by physical, chemical, and microbiological methods. A mathematical model for the sterilization effect was developed and programmed into a microprocessor that was connected to a thermocouple. The microprocessor switches on a green light when the sterilization is completed. After successful testing, the oven was built into the west-facing wall of a rural health clinic and used daily for sterilization. The oven was able to generate temperatures above 180 deg. C. On all days with direct sunlight the oven fulfilled the international recommendations for hot air sterilization because no growth could be detected from any of the test bacteria spores. The chemical indicators Brownes tubes types 3 and 5 also changed colours. The solar oven was easy to use for the clinic staff, but during the seasons with low sun position (in Tanzania, December and June) it was difficult to achieve a high enough temperature for sterilization. Therefore, if the method is to be used throughout the year the oven must be moved to collect the sun's rays from several directions, or the clinic must have more than one solar oven facing in different directions. We conclude that the solar oven is a realistic method for sterilization of instruments. (au)

  1. Laboratory studies of radiation-induced sterility on the onion maggot, delia antiqua (diptera: anthomyiidae)

    International Nuclear Information System (INIS)

    McEwen, F.L.; Ritchey, G.; Liu, H.J.

    1984-01-01

    A dose of 4 krad was the most appropriate for sterilizing pupae of Delia antiqua (Meigen) for field release: adult emergence was not reduced, emerging female flies were sterile, and the eggs produced by normal females which had mated with males irradiated as pupae had a lower hatch than those resulting from matings with normal males. Males irradiated as 6- to 8-day-old pupae were fully competitive under laboratory conditions. Continuous scrutiny of laboratory cultures to detect reduction in adult emergence or reduced competitiveness of males is stressed

  2. Study of continuous acetone-butanol fermentation by Clostridium acetobutylicum

    Energy Technology Data Exchange (ETDEWEB)

    Yarovenko, V L; Nakhmanovich, B M; Shcheblykin, N P; Senkevich, V V

    1960-01-01

    Prophylactic sterilization of small scale equipment (2 fermenters, 3.5 cu. m. each) permitted continuous fermentation through 6 cycles (28 days), each with a new inoculum of C. acetobutylicum. Single cycles could be prolonged to 6 to 11 days without sterilization. Contamination, usually with lactic acid bacteria, sometimes preceded exhaustion of the culture. Input of flour mash at 0.6 to 1.2 cu. m./hr. and withdrawal of products were continuous; acetone yield 6.6 to 7.1 g./l.; residual sugars 0.63 to 0.79%.

  3. Currently available devices for female sterilization.

    Science.gov (United States)

    Chapman, Lynne; Magos, Adam

    2005-09-01

    Sterilization is now the method of family planning most commonly used in the world. Over the last 150 years, research has evolved in the search for the ideal method of female sterilization. The procedure should ideally have high efficacy, be readily accessible and be personally and culturally acceptable. The method should be simple, quick, easily learned and be able to be performed in an outpatient setting without general anesthesia. The most common and effective method for sterilization has, thus far, been via the laparoscopic route. Hysteroscopic sterilization, however, potentially fulfills many of these ideal criteria, but until recently has remained more of a concept than a reality.

  4. Gender variation, partial male sterility and labile sex expression in gynodioecious Plantago coronopus

    NARCIS (Netherlands)

    Koelewijn, HP; VanDamme, JMM

    Gynodioecy is a breeding system consisting of male steriles (MS, females) and hermaphrodites (H). There is however within such sq stems a third, often neglected, class of partially male sterile plants (PMS), i.e. plants with an intermediate sex expression. In natural populations of Plantago

  5. Gender variation, partial male sterility and labile sex expression in gynodioecious Plantago coronopus

    NARCIS (Netherlands)

    Koelewijn, H.P.; Van Damme, J.M.M.

    1996-01-01

    Gynodioecy is a breeding system consisting of male steriles (MS, females) and hermaphrodites (H). There is however within such sq stems a third, often neglected, class of partially male sterile plants (PMS), i.e. plants with an intermediate sex expression. In natural populations of Plantago

  6. Energy analysis in sterilization process of food

    International Nuclear Information System (INIS)

    Lee, Dong Sun; Pyun, Yu Ryang

    1986-01-01

    A procedure was developed for predicting energy consumption of batch type thermal processing of food. From mass and energy balance equations various energy usages or losses were estimated for steam sterilization of model food system in No.301-7 can (Φ74.1 x 113.0mm) at three different temperatures. Selected models were 5 % bentonite solution for conductive food and tap water for convective food. Total steam or energy consumption was higher at 110 deg C than at two other higher temperatures (121 deg C and 130 deg C). High energy consumption at low sterilization temperature was mainly due to high bleeding steam energy and convective and radiative heat losses. Thermal energy efficiency was also disscussed. (Author)

  7. Compodock, a new device for sterile docking

    NARCIS (Netherlands)

    van der Meer, P. F.; Biekart, F. T.; Pietersz, R. N.; Rebers, S. P.; Reesink, H. W.

    2000-01-01

    BACKGROUND: A new device for sterile docking, the Compodock (Fresenius NPBI Transfusion Technology), was developed for connecting PVC tubing for medical use while maintaining sterility. STUDY DESIGN AND METHODS: Sterility of the connections was assessed by welding tubing with a heavy exterior

  8. MINOS Sterile Neutrino Search

    Energy Technology Data Exchange (ETDEWEB)

    Koskinen, David Jason [Univ. College London, Bloomsbury (United Kingdom)

    2009-02-01

    The Main Injector Neutrino Oscillation Search (MINOS) is a long-baseline accelerator neutrino experiment designed to measure properties of neutrino oscillation. Using a high intensity muon neutrino beam, produced by the Neutrinos at Main Injector (NuMI) complex at Fermilab, MINOS makes two measurements of neutrino interactions. The first measurement is made using the Near Detector situated at Fermilab and the second is made using the Far Detector located in the Soudan Underground laboratory in northern Minnesota. The primary goal of MINOS is to verify, and measure the properties of, neutrino oscillation between the two detectors using the v μ→ Vτ transition. A complementary measurement can be made to search for the existence of sterile neutrinos; an oft theorized, but experimentally unvalidated particle. The following thesis will show the results of a sterile neutrino search using MINOS RunI and RunII data totaling ~2.5 x 1020 protons on target. Due to the theoretical nature of sterile neutrinos, complete formalism that covers transition probabilities for the three known active states with the addition of a sterile state is also presented.

  9. Observations on female sterilization in Chile.

    Science.gov (United States)

    Menanteau-Horta, D

    1982-01-01

    Prior to 1976, voluntary female sterilization was 1 of the regular family planning services offered in Chile. After that the Ministry of Public Health declared that it could not be considered a fertility regulation activity and could thus be performed only for health reasons. Between 1971-75, there was almost a 6-fold increase in the number of sterilizations performed at the Valdivia Regional Hospital, with a rise to 2400 procedures. Such an unprecedented increase in voluntary sterilization prompted this study. The results are based on a 1976 survey of women sterilized between 1971-75 at the Valdivia Regional Hospital. Personal interviews were conducted. The number of voluntary sterilizations there during the aforementioned period showed a sustained upward trend; the number of births increased only moderately during that time. The data on sterilization in the Valdivia area is compared to that collected by the Santiago study. Age, marital status, place of origin or residence, education, and religion were compared. Socioeconomic and occupational data were also examined. 9 of 10 women in Valdivia were from low-income families. This agrees closely with the Santiago data. About 1/4 of the women in both samples were employed outside the home. Also in both samples, about 1/2 of the spouses of sterilized women were blue collar workers; only 1/5 or less were white collar, and very few were professionals. About 52% in Valdivia and 45% in Santiago had borne 7 or more viable offspring. The average number of spontaneous abortions was also similar. A significantly higher percentage (P0.01) of Valdivia women used contraceptives. There are some general trends apparent in both groups as to the reasons for sterilization; most were prompted by difficult socioeconomic conditions. 37.9% of the Santiago women felt their families were complete and 27.3% of the other group cited the same reason. Other reasons were medical, failure of contraception, problems with spouse, and other. Medical

  10. Engineered Dwarf Male-Sterile Rice: A Promising Genetic Tool for Facilitating Recurrent Selection in Rice.

    Science.gov (United States)

    Ansari, Afsana; Wang, Chunlian; Wang, Jian; Wang, Fujun; Liu, Piqing; Gao, Ying; Tang, Yongchao; Zhao, Kaijun

    2017-01-01

    Rice is a crop feeding half of the world's population. With the continuous raise of yield potential via genetic improvement, rice breeding has entered an era where multiple genes conferring complex traits must be efficiently manipulated to increase rice yield further. Recurrent selection is a sound strategy for manipulating multiple genes and it has been successfully performed in allogamous crops. However, the difficulties in emasculation and hand pollination had obstructed efficient use of recurrent selection in autogamous rice. Here, we report development of the dwarf male-sterile rice that can facilitate recurrent selection in rice breeding. We adopted RNAi technology to synergistically regulate rice plant height and male fertility to create the dwarf male-sterile rice. The RNAi construct pTCK-EGGE, targeting the OsGA20ox2 and OsEAT1 genes, was constructed and used to transform rice via Agrobacterium -mediated transformation. The transgenic T0 plants showing largely reduced plant height and complete male-sterile phenotypes were designated as the dwarf male-sterile plants. Progenies of the dwarf male-sterile plants were obtained by pollinating them with pollens from the wild-type. In the T1 and T2 populations, half of the plants were still dwarf male-sterile; the other half displayed normal plant height and male fertility which were designated as tall and male-fertile plants. The tall and male-fertile plants are transgene-free and can be self-pollinated to generate new varieties. Since emasculation and hand pollination for dwarf male-sterile rice plants is no longer needed, the dwarf male-sterile rice can be used to perform recurrent selection in rice. A dwarf male-sterile rice-based recurrent selection model has been proposed.

  11. Feasibility Study of Aseptic Homogenization: Affecting Homogenization Steps on Quality of Sterilized Coconut Milk

    Directory of Open Access Journals (Sweden)

    Phungamngoen Chanthima

    2016-01-01

    Full Text Available Coconut milk is one of the most important protein-rich food sources available today. Separation of an emulsion into an aqueous phase and cream phase is commonly occurred and this leads an unacceptably physical defect of either fresh or processed coconut milk. Since homogenization steps are known to affect the stability of coconut milk. This work was aimed to study the effect of homogenization steps on quality of coconut milk. The samples were subject to high speed homogenization in the range of 5000-15000 rpm under sterilize temperatures at 120-140 °C for 15 min. The result showed that emulsion stability increase with increasing speed of homogenization. The lower fat particles were generated and easy to disperse in continuous phase lead to high stability. On the other hand, the stability of coconut milk decreased, fat globule increased, L value decreased and b value increased when the high sterilization temperature was applied. Homogenization after heating led to higher stability than homogenization before heating due to the reduced particle size of coconut milk after aggregation during sterilization process. The results implied that homogenization after sterilization process might play an important role on the quality of the sterilized coconut milk.

  12. Current status and future prospect of electron beam sterilization in Japan

    International Nuclear Information System (INIS)

    Katsura, Ichiro

    1998-01-01

    It seems that electron beam sterilization is being current topic among all applications in Japan and that this tendency will continue until when major companies interested in the technology complete introducing electron beam. Since the Ministry of Health and Welfare(MOHW) officially issued revised regulation on GMP for medical devices in 1995, EtO has become the method regarded as time and money consuming one. On the contrary, electron beam has become as relatively economical and desirable method to achieve same result by its characteristics such as high productivity, rather easy validation and consequent cost reduction, although less penetration limit the kind of products to be treated. Status and prospect of electron beam sterilization in Japan will be presented in the paper along with accelerator related technologies

  13. Use of sterile insect technique in Brazil by the sterilization of Ceratitis capitata (Wied., 1824)

    International Nuclear Information System (INIS)

    Okeese, G.O.; Kitomer, T.J.; Gayaradus, L.B.; Etrigan, M.; Jansen, C.W.J.H.; Houlahar, H.L.

    2006-01-01

    The Sterile Insect Technique is a method of pest control allowed in Integrated Pest Management programs in fruit growing, where sterile insects released compete in mate process against fertile wild ones, generating a gradative population reduction. The most used sterilization method is using ionizing radiation from 60 Co or 137 Cs. For efficient application of SIT, an important item is the sterilizing dose. This must be as lower as possible in order to preserve insect behavior. In this work, it was studied the reproductive potential of fruit fly Ceratitis capitata, tsl VIENNA 8 strain, irradiated with different doses of gamma radiation. This strain has been used in population suppression programs at fruit-growing areas from Northeast of Brazil, through a partnership between CENA and Bio factory MOSCAMED Brazil, intending only sterile male releases. Radiation source used was a 60 Co irradiator, with 17.2 x 1012 Bq. Individualized couples were distributed in a randomized delineament with 10 replicates for each treatment and eggs were collected for fifteen days. With 9 and 10 days old, pupae were irradiated with doses ranging from 30 to 120 Gy. All averages of emerged adult's percentages were higher than 90%. In regards to fecundity, different doses did not affect the number of eggs laid, being the overall mean around 30 eggs/couple/day. Fertility data showed that as radiation dose increases, sterility increases. It was concluded that the dose of 90 Gy can be used in Brazil, since to SIT programs a dose is chosen witch prevents an egg hatch higher than 1%. (author)

  14. The effect of endoscopic sterilization on reproductive behavior and pair bond maintenance of feral pigeons (Columba livia).

    Science.gov (United States)

    Heiderich, E; Failing, K; Lierz, M; Schildger, B

    2016-01-01

    Problems related to feral pigeons (Columba livia) in cities mainly result from their large numbers due to uncontrolled population growth. The aim of this study was to evaluate whether endoscopic guided sterilization affects the reproductive behavior of feral pigeons under experimental conditions, with the intention of assessing this technique as a potential method for feral pigeon population control. Five groups of four pairs of feral pigeons each were studied from 8 weeks before, to 7 weeks after sterilization. Both the male and female of the first pair of each group were sterilized, in the second pair only the female and in the third pair only the male was sterilized. The fourth pair acted as a control. All eggs laid were candled to assess fertility. Surgical sterilization had minimal effects on behavior and therefore seems not to have impact on possible field application for population control. All pairs maintained their pair bonds and continued to defend their nesting sites against other pigeons. Only one female copulated with a foreign fertile male while her primary partner was debilitated due to surgery, but returned to him as soon as he recovered. All eggs laid more than 5 days after male sterilization were infertile, whereas all control pairs had fertile eggs. Only one fertile clutch was produced, 5 days after the male's sterilization. Therefore it is assumed that males remain fertile for a limited period of time. Endoscopic sterilization seems to be a promising method for field control of feral pigeon populations and sterilization of the male only seems sufficient.

  15. Sterilization of single-use helical stone baskets: an experimental study

    Directory of Open Access Journals (Sweden)

    Cely Barreto da Silva

    2011-03-01

    Full Text Available Objectives: To experimentally evaluate the efficacy of a standard sterilization protocol employed during reuse of disposable helical stone baskets. Methods: Study performed on 20 helical stone baskets: 10 were used in the initial validation process, contaminated with Escherichia coli ATCC 25922 and imprinted on Müeller-Hinton media; 10 catheters were contaminated with Geobacillus stearothermophilus ATCC 7953, processed, inoculated in TSB and incubated in a water bath at a temperature of 55ºC. Bacterial growth was evaluated after 1, 3, 5 and 7 days. After sterilization, stone baskets were also opened and closed 40 times to check for functional problems. All plastic and basket parts were carefully checked for damages. Results: After the 72-hour incubation period, there was growth of E. coli ATCC 25922 in 100% of imprints. After the sterilization process and up to 7 days incubation period on a blood agar plate, there was no growth of G. stearothermophilus ATCC 7953 or any other bacteria. There were no functional problems or damage to baskets after the sterilization process. Conclusion: The ethylene oxide system is efficacious and safe for sterilization of disposable helical stone baskets. However, further clinical studies are required and should provide more safety information.

  16. Sensitivity of viruses to radiation sterilization

    International Nuclear Information System (INIS)

    Dziedzic Goclawska; A

    1999-01-01

    The hazard of infectious disease transmission with tissue allografts is a major concern in tissue banking practice. Microorganisms can be introduced into grafts during tissue collection, processing and storage, but even when all these procedures are performed under a septic conditions, the possibility of fungal, bacterial or viral disease transmission of donor origin can not be excluded. Therefore, in order to minimize the risk of infectious disease transmission, several steps should be undertaken, including a careful donor screening, proper tissue processing and sterilization of tissue allografts. The risk of transmission of viral infections such as hepatitis B, C, other viruses and particularly HIV with tissue allografts is of great significance and the search for sterilizing methods which inactivate and/or highly reduce viral infectivity continues. Sterilization of tissue allografts with ionizing radiation (introduced in the mid of 1950s) is increasingly used in tissue banking practice. The effectiveness of the radiation-sterilization procedure depends on the amount of energy transferred, the number of contaminating microorganisms and their resistance to ionizing radiation (initial contamination, bioburden). Usually, spores are more resistant than vegetative forms of bacteria, some fungi may be as resistant as bacterial spores, and viruses are, in general, more resistant than bacteria. Dita concerning effectiveness of ionizing radiation to inactivate viruses (e.g. such as HBV, HCV or HIV) in tissue allografts collected from cadavers are scarce. It has been found that the dose of irradiation needed to reduce HIV load by I log10 unit (D10) is about 4.0 kGy or even 5.6 kGy. The level of infectious HIV in plasma is usually evaluated by titration of tissue culture infective dose (TCID50/ml). Taking into consideration the recommended sterility assurance level (SAL) 10-6, assuming the HIV bioburden to be 103 TCID50/ml for the state of acute infection and D10 value of 4

  17. The smart aerial release machine, a universal system for applying the sterile insect technique: Manuscript Draft

    International Nuclear Information System (INIS)

    Mubarqui, Leal Ruben; Perez, Rene Cano; Klad, Roberto Angulo; Lopez, Jose L. Zavale; Parker, Andrew; Seck, Momar Talla; Sall, Baba; Bouyer, Jeremy

    2014-01-01

    Beyond insecticides, alternative methods to control insect pests for agriculture and vectors of diseases are needed. Management strategies involving the mass-release of living control agents have been developed, including genetic control with sterile insects and biological control with parasitoids, for which aerial release of insects is often required. Aerial release in genetic control programmes often involves the use of chilled sterile insects, which can improve dispersal, survival and competitiveness of sterile males. Currently available means of aerially releasing chilled fruit flies are however insufficiently precise to ensure homogeneous distribution at low release rates and no device is available for tsetse. Here we present the smart aerial release machine, a new design by the Mubarqui Company, based on the use of vibrating conveyors. The machine is controlled through Bluetooth by a tablet with Android Operating System including a completely automatic guidance and navigation system (MaxNav software). The tablet is also connected to an online relational database facilitating the preparation of flight schedules and automatic storage of flight reports. The new machine was compared with a conveyor release machine in Mexico using two fruit flies species (Anastrepha ludens and Ceratitis capitata) and we obtained better dispersal homogeneity (% of positive traps, p < 0.001) for both species and better recapture rates for Anastrepha ludens (p < 0.001), especially at low release densities (<1500 per ha). We also demonstrated that the machine can replace paper boxes for aerial release of tsetse in Senegal.This technology limits damages to insects and allows a large range of release rates from 10 flies/km"2 for tsetse flies up to 600 000 flies/km"2 for fruit flies. The potential of this machine to release other species like mosquitoes is discussed. Plans and operating of the machine are provided to allow its use worldwide.

  18. Sterilization of heparinized cuprophan hemodialysis membranes

    OpenAIRE

    ten Hoopen, Hermina W.M.; Hinrichs, W.L.J.; Hinrichs, W.L.J.; Engbers, G.H.M.; Feijen, Jan

    1996-01-01

    The effects of sterilization of dry heparinized Cuprophan hemodialysis membranes by means of ethylene oxide (EtO) exposure, gamma irradiation, or steam on the anticoagulant activity and chemical characteristics of immobilized heparin and the permeability of the membrane were investigated. Sterilization did not result in a release of heparin or heparin fragments from heparinized Cuprophan. Sterilization of heparinized Cuprophan by means of EtO exposure and gamma irradiation induced a slight, i...

  19. EB surface sterilization of food material

    International Nuclear Information System (INIS)

    Kaneko, H.; Mizutani, A.; Kato, K.; Nishikimi, T.; Taniguchi, S.

    2001-01-01

    In this paper, we introduce a food irradiation with low energetic, lower than 300keV, electrons (so-called SOFT ELECTRON) as a rather new method of food sterilization. It is also a physical sterilization method, and free from the problems mentioned above. Low energetic electrons have small penetration power (50-200micron) through raw materials, and by selecting a proper energy of electrons we can sterilize only the surfaces or skins of target materials

  20. Genetic basis of the sterile insect technique

    International Nuclear Information System (INIS)

    Robinson, A.S.

    2005-01-01

    The use of the sterile insect technique (SIT) for insect control relies on the introduction of sterility in the females of the wild population. This sterility is produced following the mating of these females with released males carrying, in their sperm, dominant lethal mutations that have been induced by ionizing radiation. The reasons why the SIT can only be effective when the induced sterility in the released males is in the form of dominant lethal mutations, and not some form of sperm inactivation, are discussed, together with the relationship of dominant lethal mutations to dose, sex, developmental stage and the particular species. The combination of genetic sterility with that induced by radiation is also discussed in relation to the use of genetic sexing strains of the Mediterranean fruit fly Ceratitis capitata (Wiedemann) in area-wide integrated pest management (AW-IPM) programmes that integrate the SIT. A case is made to lower the radiation dose used in such programmes so as to produce a more competitive sterile insect. Increased competitiveness can also be achieved by using different radiation environments. As well as radiation-induced sterility, natural mechanisms can be recruited, especially the use of hybrid sterility exemplified by a successful field trial with tsetse flies Glossina spp. in the 1940s. Genetic transformation will make some impact on the SIT, especially regarding the introduction of markers for released flies, and the construction of genetic sexing strains. It is concluded that using a physical process, such as radiation, will always have significant advantages over genetic and other methods of sterilization for the large-scale application of the SIT. (author)

  1. Phenology, sterility and inheritance of two environment genic male sterile (EGMS) lines for hybrid rice

    NARCIS (Netherlands)

    El-Namaky, R.; Oort, van P.A.J.

    2017-01-01

    Background: There is still limited quantitative understanding of how environmental factors affect sterility of Environment-conditioned genic male sterility (EGMS) lines. A model was developed for this purpose and tested based on experimental data from Ndiaye (Senegal) in 2013-2015. For the two

  2. An unedited 1.1 kb mitochondrial orfB gene transcript in the Wild Abortive Cytoplasmic Male Sterility (WA-CMS system of Oryza sativa L. subsp. indica

    Directory of Open Access Journals (Sweden)

    Maiti Mrinal K

    2010-03-01

    Full Text Available Abstract Background The application of hybrid rice technology has significantly increased global rice production during the last three decades. Approximately 90% of the commercially cultivated rice hybrids have been derived through three-line breeding involving the use of WA-CMS lines. It is believed that during the 21st century, hybrid rice technology will make significant contributions to ensure global food security. This study examined the poorly understood molecular basis of the WA-CMS system in rice. Results RFLPs were detected for atp6 and orfB genes in sterile and fertile rice lines, with one copy of each in the mt-genome. The RNA profile was identical in both lines for atp6, but an additional longer orfB transcript was identified in sterile lines. 5' RACE analysis of the long orfB transcript revealed it was 370 bp longer than the normal transcript, with no indication it was chimeric when compared to the genomic DNA sequence. cDNA clones of the longer orfB transcript in sterile lines were sequenced and the transcript was determined unedited. Sterile lines were crossed with the restorer and maintainer lines, and fertile and sterile F1 hybrids were respectively generated. Both hybrids contained two types of orfB transcripts. However, the long transcript underwent editing in the fertile F1 hybrids and remained unedited in the sterile lines. Additionally, the editing of the 1.1 kb orfB transcript co-segregated with fertility restoring alleles in a segregating population of F2 progeny; and the presence of unedited long orfB transcripts was detected in the sterile plants from the F2 segregating population. Conclusion This study helped to assign plausible operative factors responsible for male-sterility in the WA cytoplasm of rice. A new point of departure to dissect the mechanisms governing the CMS-WA system in rice has been identified, which can be applied to further harness the opportunities afforded by hybrid vigor in rice.

  3. Comparative mating and reproductive performance of radiation sterilized and radiation induced F1 sterile males of Earias vittella (Fabricius)

    International Nuclear Information System (INIS)

    Shantharam, K.; Tamhankar, A.J.; Harwalkar, M.R.

    1995-01-01

    Studies were conducted on mating behaviour and reproductive performance of a) Earias vittella (F.) males rendered sterile by exposing them to 300 Gy gamma rays and b) F 1 sterile males obtained by exposing parent male to 100 Gy gamma rays. For the study, males were allowed only one mating with a normal female. Results revealed that premating period, period in copula and per cent insects mating were not adversely affected in case of both types of sterile males and fecundity also remained unaffected. However, in both types of sterile males, incidence of spermatophore transfer without sperm was very large and such an occurrence (including reduced spermatophore transfer) was significantly higher in case of radiation sterilized males compared to the F 1 sterile males. Inability to produce and transfer spermatophore and/or sperm appeared to be a major cause behind the reduced mating competitiveness of both types of males. (author). 22 refs., 2 tabs

  4. Pre-sterilization contamination of disposable medical products and the choice of minimum sterilization dose

    International Nuclear Information System (INIS)

    Horakova, V.; Buriankova, E.

    1975-01-01

    The bacterial contamination was assessed on randomly taken samples of blood-transfusion devices, donor sets, intra-uterine contraceptive devices and inserters, surgical gloves and dressing material prior to sterilization. The quantitative and qualitative efficiency of six nutrient media was compared. The best results were obtained with the enriched ''Universal'' medium. It was confirmed that the contamination of plastic products was low compared with dressing material. Most frequently, Gram-positive aerobic spore-forming rods and Gram-positive cocci were found on non-sterile medical disposable products. A method was tested to obtain a general informative picture of the resistance of bacteria on products. The methods used for choosing the dose for radiation sterilization of medical products are discussed. (author)

  5. Dissecting the genetic architecture of F1 hybrid sterility in house mice.

    Science.gov (United States)

    Dzur-Gejdosova, Maria; Simecek, Petr; Gregorova, Sona; Bhattacharyya, Tanmoy; Forejt, Jiri

    2012-11-01

    Hybrid sterility as a postzygotic reproductive isolation mechanism has been studied for over 80 years, yet the first identifications of hybrid sterility genes in Drosophila and mouse are quite recent. To study the genetic architecture of F(1) hybrid sterility between young subspecies of house mouse Mus m. domesticus and M. m. musculus, we conducted QTL analysis of a backcross between inbred strains representing these two subspecies and probed the role of individual chromosomes in hybrid sterility using the intersubspecific chromosome substitution strains. We provide direct evidence that the asymmetry in male infertility between reciprocal crosses is conferred by the middle region of M. m. musculus Chr X, thus excluding other potential candidates such as Y, imprinted genes, and mitochondrial DNA. QTL analysis identified strong hybrid sterility loci on Chr 17 and Chr X and predicted a set of interchangeable autosomal loci, a subset of which is sufficient to activate the Dobzhansky-Muller incompatibility of the strong loci. Overall, our results indicate the oligogenic nature of F(1) hybrid sterility, which should be amenable to reconstruction by proper combination of chromosome substitution strains. Such a prefabricated model system should help to uncover the gene networks and molecular mechanisms underlying hybrid sterility. © 2012 The Author(s). Evolution© 2012 The Society for the Study of Evolution.

  6. Dosimetry for electron beam sterilization

    International Nuclear Information System (INIS)

    Miller, A.

    2007-01-01

    According to ISO 11137-1 (sect 4.3.4) dosimetry used in the development, validation and routine control of the sterilization process shall have measurement traceability to national or international standards and shall have a known level of uncertainty. It can only be obtained through calibration of the dosimeters. In presented lecture different types of dosimeter systems for electron beams (calorimeters, radiochromic film dosimeters, alanine / EPR) and their calibration are described

  7. Recurrent population improvement of rice breeding facilitated with male sterility

    International Nuclear Information System (INIS)

    Fujimaki, Hiroshi

    1982-01-01

    A new rice breeding system has been developed, making use of genic male sterility to utilize diverse breeding materials and to promote genetic recombination. In this system, recurrent selection technique and introgressive hybridization were used to increase the frequencies of producing desired genotypes and to improve the population in succession. To promote genetic recombination by the recurrent selection technique, intermating within the population is necessary, and to introduce useful germ plasms by the introgressive hybridization, back crossing with new genetic material is necessary. These can be done efficiently by using the recessive alleles for male sterility, and the representative models for thisF type of breeding were presented. (Kaihara, S.)

  8. Evaluation of user input methods for manipulating a tablet personal computer in sterile techniques.

    Science.gov (United States)

    Yamada, Akira; Komatsu, Daisuke; Suzuki, Takeshi; Kurozumi, Masahiro; Fujinaga, Yasunari; Ueda, Kazuhiko; Kadoya, Masumi

    2017-02-01

    To determine a quick and accurate user input method for manipulating tablet personal computers (PCs) in sterile techniques. We evaluated three different manipulation methods, (1) Computer mouse and sterile system drape, (2) Fingers and sterile system drape, and (3) Digitizer stylus and sterile ultrasound probe cover with a pinhole, in terms of the central processing unit (CPU) performance, manipulation performance, and contactlessness. A significant decrease in CPU score ([Formula: see text]) and an increase in CPU temperature ([Formula: see text]) were observed when a system drape was used. The respective mean times taken to select a target image from an image series (ST) and the mean times for measuring points on an image (MT) were [Formula: see text] and [Formula: see text] s for the computer mouse method, [Formula: see text] and [Formula: see text] s for the finger method, and [Formula: see text] and [Formula: see text] s for the digitizer stylus method, respectively. The ST for the finger method was significantly longer than for the digitizer stylus method ([Formula: see text]). The MT for the computer mouse method was significantly longer than for the digitizer stylus method ([Formula: see text]). The mean success rate for measuring points on an image was significantly lower for the finger method when the diameter of the target was equal to or smaller than 8 mm than for the other methods. No significant difference in the adenosine triphosphate amount at the surface of the tablet PC was observed before, during, or after manipulation via the digitizer stylus method while wearing starch-powdered sterile gloves ([Formula: see text]). Quick and accurate manipulation of tablet PCs in sterile techniques without CPU load is feasible using a digitizer stylus and sterile ultrasound probe cover with a pinhole.

  9. Sterile neutrinos as dark matter

    International Nuclear Information System (INIS)

    Dodelson, S.; Widrow, L.M.

    1994-01-01

    The simplest model that can accommodate a viable nonbaryonic dark matter candidate is the standard electroweak theory with the addition of right-handed (sterile) neutrinos. We consider a single generation of neutrinos with a Dirac mass μ and a Majorana mass M for the right-handed component. If M much-gt μ (standard hot dark matter corresponds to M=0), then sterile neutrinos are produced via oscillations in the early Universe with energy density independent of M. However, M is crucial in determining the large scale structure of the Universe; for M∼100 eV, sterile neutrinos make an excellent warm dark matter candidate

  10. Application of radiation sterilization to bone allografts

    International Nuclear Information System (INIS)

    Li Youchen; Li Baoxing; Sun Shiquan

    2003-01-01

    With prominent features of high penetration, no temperature increases, no harm residues and easy dose control, radiation sterilization technology is widely used in the sterilization of bone allografts. During the radiation sterilization of bone allografts, the irradiation dose should be optimized to ensure sterilization of grafts and preservation of biological properties of bone. The immunogenicity of allografts is decreased by irradiation. IAEA devoted great efforts to generalization of the radiation sterilization of tissue allografts in developing countries since 1986. Tissue Bank of China Institute for Radiation Protection (CIRP) was initially established in 1988 with the support of IAEA, afterwards restructured into Shanxi Provincial Tissue Bank (SPTB). The SPTB, as the first manufacturer of the irradiated bone allografts in the country, was granted production license by the State Food and Drug Administration of China. The SPTB sponsored IAEA/RCA Training Courses, National Symposium on Bone Grafting, and National Training Course on Bone Banking. Technique of radiation sterilization for bone grafts has become popularized in China after these activities. (authors)

  11. Radiation sterilization of some pharmaceutical preparations and medical products

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.; Makhkamov, Sh.M.; Urinov, Sh.S.; Turaev, A.S.; Sultanov, M.S.; Inagomov, Kh.S.

    2006-01-01

    Full text: In connection with intensive development of pharmacology and medical techniques, use of the products contacting to blood, with the internal environment of an organism, with wound surface, with mucous membranes and skin there were high requirements to sterility of pharmaceutical preparations and medical products. Traditional methods of sterilization (heat treatment, gas processing and processing the ferry) have some restrictions in application, and not insufficient degree of sterilization required for pharmaceutical preparations and medical products. Thermal processing can lead to degradation of structure (medicine), mechanical changes and loss of medical properties. Besides, it is impossible to carry out sterilization of many pharmaceutical preparations by a method of heat treatment. Sterilization of products in packing is very complicated, because sterilization temperature of packing and a product is different. Gas processing is basically applied to sterilization of medical products (syringes, bandage, cotton wools, etc.). However, the degree of sterility is low, because of rather low ability and heterogeneity of sterilizing substance. Sterilization in packing represents special difficulty and demands additional charges related with delivery of the purified gas from abroad. Last years alongside with known technological methods of sterilization of medical products and pharmaceutical preparations radiating methods of processing have found wide application. Use of electronic bunches with the moderate energy and various isotopes became a basis for formation and development of a new direction in the medicine, called by 'radiation sterilization'. The radiation technology is highly harmless and economic, not polluting substance and surrounding space. Unlike the specified traditional methods, radiating processing of products by the isotope 60 Co, radiating the gamma quantum, has unique opportunities - high penetrability in substance, providing uniformity of

  12. Peracetic Acid: A Practical Agent for Sterilizing Heat-Labile Polymeric Tissue-Engineering Scaffolds

    Science.gov (United States)

    Yoganarasimha, Suyog; Trahan, William R.; Best, Al M.; Bowlin, Gary L.; Kitten, Todd O.; Moon, Peter C.

    2014-01-01

    Advanced biomaterials and sophisticated processing technologies aim at fabricating tissue-engineering scaffolds that can predictably interact within a biological environment at the cellular level. Sterilization of such scaffolds is at the core of patient safety and is an important regulatory issue that needs to be addressed before clinical translation. In addition, it is crucial that meticulously engineered micro- and nano- structures are preserved after sterilization. Conventional sterilization methods involving heat, steam, and radiation are not compatible with engineered polymeric systems because of scaffold degradation and loss of architecture. Using electrospun scaffolds made from polycaprolactone, a low melting polymer, and employing spores of Bacillus atrophaeus as biological indicators, we compared ethylene oxide, autoclaving and 80% ethanol to a known chemical sterilant, peracetic acid (PAA), for their ability to sterilize as well as their effects on scaffold properties. PAA diluted in 20% ethanol to 1000 ppm or above sterilized electrospun scaffolds in 15 min at room temperature while maintaining nano-architecture and mechanical properties. Scaffolds treated with PAA at 5000 ppm were rendered hydrophilic, with contact angles reduced to 0°. Therefore, PAA can provide economical, rapid, and effective sterilization of heat-sensitive polymeric electrospun scaffolds that are used in tissue engineering. PMID:24341350

  13. History of sterile compounding in U.S. hospitals: learning from the tragic lessons of the past.

    Science.gov (United States)

    Myers, Charles E

    2013-08-15

    The evolution of sterile compounding in the context of hospital patient care, the evolution of related technology, past incidents of morbidity and mortality associated with preparations compounded in various settings, and efforts over the years to improve compounding practices are reviewed. Tightened United States Pharmacopeial Convention standards (since 2004) for sterile compounding made it difficult for hospitals to achieve all of the sterile compounding necessary for patient care. Shortages of manufactured injections added to the need for compounding. Non-hospital-based compounding pharmacies increased sterile compounding to meet the needs. Gaps in federal and state laws and regulations about compounding pharmacies led to deficiencies in their regulation. Lapses in sterility led to injuries and deaths. Perspectives offered include potential actions, including changes in practitioner education, better surveillance of sterile compounding, regulatory reforms, reexamination of the causes of drug shortages, and the development of new technologies. Over the years, there have been numerous exhortations for voluntary better performance in sterile compounding. In addition, professional leadership has been vigorous and extensive in the form of guidance, publications, education, enforceable standards, and development of various associations and organizations dealing with safe compounding practices. Yet problems continue to occur. We must engage in diligent learning from the injuries and tragedies that have occurred. Assuming that we are already doing all we can to avoid problems would be an abdication of the professional mission of pharmacists. It would be wrong thinking to assume that the recent problems in large-scale compounding pharmacies are the only problems that warrant attention. It is time for a systematic assessment of the nature and the dimensions of the problems in every type of setting where sterile compounding occurs. It also is time for some innovative

  14. Biological wound dressings sterilized with gamma radiation: Mexican clinical experience

    Science.gov (United States)

    Martínez-Pardo, M. E.; Ley-Chávez, E.; Reyes-Frías, M. L.; Rodríguez-Ferreyra, P.; Vázquez-Maya, L.; Salazar, M. A.

    2007-11-01

    Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is "Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation". At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue processing, as well as the present Mexican clinical experience with children and adult patients who underwent medical treatment with radiosterilized amnion and pig skin, used as biological wound dressings on burns and ocular surface disorders.

  15. Biological wound dressings sterilized with gamma radiation: Mexican clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Martinez-Pardo, M.E. [Instituto Nacional de Investigaciones Nucleares, Apdo. postal 18-1027, Col. Escandon 11801 Mexico DF (Mexico)], E-mail: memp@nuclear.inin.mx; Ley-Chavez, E. [ISSEMYM Toluca, Mexico DF (Mexico); Reyes-Frias, M.L. [Instituto Nacional de Investigaciones Nucleares, Apdo. postal 18-1027, Col. Escandon 11801 Mexico DF (Mexico); Rodriguez-Ferreyra, P. [Hospital ' Dr. Nicolas San Juan' , Toluca, Mexico DF (Mexico); Vazquez-Maya, L.; Salazar, M.A. [Hospital General de Mexico, Mexico DF (Mexico)

    2007-11-15

    Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is 'Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation'. At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue processing, as well as the present Mexican clinical experience with children and adult patients who underwent medical treatment with radiosterilized amnion and pig skin, used as biological wound dressings on burns and ocular surface disorders.

  16. Biological wound dressings sterilized with gamma radiation: Mexican clinical experience

    International Nuclear Information System (INIS)

    Martinez-Pardo, M.E.; Ley-Chavez, E.; Reyes-Frias, M.L.; Rodriguez-Ferreyra, P.; Vazquez-Maya, L.; Salazar, M.A.

    2007-01-01

    Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is 'Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation'. At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief description of the tissue processing, as well as the present Mexican clinical experience with children and adult patients who underwent medical treatment with radiosterilized amnion and pig skin, used as biological wound dressings on burns and ocular surface disorders

  17. Dispersal and survival of sterile male (TSL strain) Mediterranean fruit flies

    International Nuclear Information System (INIS)

    Barbosa, S.; Mexia, A.; Pereira, R.

    2000-01-01

    The Mediterranean fruit fly, Ceratitis capitata (Weid.), is a major pest of fruit in the Portuguese Autonomous Region of Madeira (Vieira 1952). The Medfly attacks more than 40 species of fruit (Vieira 1952, Pereira et al. 1996). It was reported as a pest primarily below 400 m but occurred up to 700 m on the south coast. Madeira (32 deg. N, 17 deg. W) is located 980 km west-southeast of mainland Portugal. Its two principal islands (Porto Santo (50 km 2 ) and Madeira (740 km 2 )) are populated by 255,000 people. Fruit and vegetable production is widespread on Madeira island but not on Porto Santo island because of poor soil and limited rainfall. The climate of Madeira is variable, depending upon altitude and location (northern/southern). On the whole, the climate is moderated by the effects of the surrounding sea. The sterile insect technique (SIT) is a genetic method of insect control. Large numbers (frequently more than 50 million/week) of the target insect are reared in specially designed factories (Pereira et al., in press). These insects are sterilised with gamma radiation and released by aircraft into the target area. Mating between the factory reared sterile males and fertile wild females produces no progeny. Thus, if sufficient sterile males are introduced into the target area on a continuous basis there is a very high probability that fertile wild females will mate with sterile males (Hendrichs et al. 1995). Under these conditions, the birth rate of the target species is greatly reduced and will rapidly reach zero if no fertile insects are brought into the target area. Little work has been done with all male releases because it is only very recently that all male strains have been mass produced. It has been postulated that releasing only sterile male Medflies could result in better distribution and perhaps increased longevity of the released individuals. To evaluate this hypothesis, tests of longevity and dispersion of sterile males were conducted. Ground

  18. Development of Novel Cytoplasmic Male Sterile Source from Dongxiang Wild Rice (Oryza rufipogon

    Directory of Open Access Journals (Sweden)

    Xian-hua SHEN

    2013-09-01

    Full Text Available This study was conducted to develop and characterize a novel cytoplasmic male sterile (CMS source which was identified from Dongxiang wild rice (Oryza rufipogon by crossing Dongxiang wild rice as female with Zhongzao 35, an indica inbred variety, as male and continuous backcrossing with Zhongzao 35. Observation under optical microscope manifested that this novel CMS belonged to typical abortion type with less pollen compared with wild abortive type cytoplasm (CMS-WA. Sequential planting showed that this novel CMS has complete and stable male sterility. Testcross experiment showed that all the 24 tested materials including maintainer and restorer lines of CMS-WA and Honglian type cytoplasm (CMS-HL and other indica inbred varieties are the maintainers with complete maintaining ability, suggesting that this novel CMS has fertility restoration totally different from CMS-WA and CMS-HL and belongs to a novel type of CMS. So far, we only discovered a unique fertility restoration source for this novel CMS. Inheritance analysis showed that the fertility restoration of this CMS was governed by three pairs of independent dominant genes. Prospect for application of this novel CMS system in hybrid rice breeding was also discussed.

  19. Sterilization of ready to eat meals destined to immunocompromised by irradiation

    International Nuclear Information System (INIS)

    Berhouma, Hiba

    2011-01-01

    Immunocompromised patients who have a dysfunction in one or more components of the immune system must follow a diet low in bacteria. Several methods are used to obtain this type of system such as pasteurization (65-10 degree), wet sterilization (120 degree - 140 degree UHT) or dry ( 180 degree), heating in the oven convection ((250 degree) and radappertization). In Tunisia, the CNGMO uses sterilization in a forced air oven 120 degree for 20 min. Of high radiation doses 5, 10 and 15 KGy were used in this study to achieve sterilization of Couscous. The dose of 5 KGy improves the bacteriological quality (reduce the microbial load of 2048 to 1 log CFU/g) of this dish while preserving the organoleptic qualities. The comparison sample irradiated 5 KGy and the heat-treated seems to be very close during the various tests. except that the heat-treated has a high oxidation state (TBARS value of 7900.90 mg / kg).

  20. EPR STUDIES OF THERMALLY STERILIZED VASELINUM ALBUM.

    Science.gov (United States)

    Ramos, Paweł; Pilawa, Barbara

    2015-01-01

    Electron paramagnetic resonance (EPR) spectroscopy was used for examination of free radicals in thermally treated vaselinum album (VA). Thermal treatment in hot air as sterilization process was tested. Conditions of thermal sterilization were chosen according to the pharmaceutical norms. Vaselinum album was heated at the following conditions (T--temperature, t--time): T = 160°C and t = 120 min, T = 170°C and t = 60 min and T = 180°C and t = 30 min. The aim of this work was to determine concentration and free radical properties of thermally sterilized VA. EPR analysis for VA was done 15 min after sterilization. EPR measurements were done at room temperature. EPR spectra were recorded in the range of microwave power of 2.2-70 mW. g-Factor, amplitudes (A) and line width (ΔBpp) of the spectra were determined. The shape of the EPR spectra was analyzed. Free radical concentration (N) in the heated samples was determined. EPR spectra were not obtained for the non heated VA. EPR spectra were detected for all thermally sterilized samples. The spectra revealed complex character, their asymmetry depends on microwave power. The lowest free radicals concentration was found for the VA sterilized at 180°C during 30 min. EPR spectroscopy is proposed as the method useful for optimization of sterilization process of drugs.

  1. [Determinants of sterilization among married couples in Korea].

    Science.gov (United States)

    Kim, Ju Hee; Chung, Woojin; Lee, Sunmi; Suh, Moonhee; Kang, Dae Ryong

    2007-11-01

    The purpose of this study was to examine the determinants of sterilization in South Korea. This study was based on the data from the Korea National Fertility Survey carried out in the year 2000 by the Korea Institute of Health and Social Affairs. The subjects of the analysis were 4,604 women and their husbands who were in their first marriage, in the age group of 15-49 years. The data were analyzed by multiple logistic regression analysis. Consistent with the findings of previous studies, the woman's age and the number of total children increased the likelihood of sterilization. In addition, the year of marriage had a strong positive association with sterilization. Interestingly, the number of surviving sons tended to increase the likelihood of sterilization, whereas the woman's education level and age at the time of marriage showed a negative association with sterilization. Religion, place of residence, son preference, and the husband's education level, age and type of occupation were not significant determinants of sterilization. The sex of previous children and lower level of education are distinct determinants of sterilization among women in South Korea. More studies are needed in order to determine the associations between sterilization rate and decreased fertility.

  2. [Assessment of decontamination processes: cleaning, disinfection and sterilization in dental practice in Poland in the years 2011-2012].

    Science.gov (United States)

    Röhm-Rodowald, Ewa; Jakimiak, Bozenna; Chojecka, Agnieszka; Zmuda-Baranowska, Magdalena; Kanclerski, Krzysztof

    2012-01-01

    Effective decontamination of instruments is a key element of infection control and the provision of high quality in dental care. The aim of the study was to evaluate the efficiency of decontamination procedures including cleaning, disinfection and sterilization of re-usable instruments in dental practices in Poland. The efficiency of disinfection and sterilization processes have been evaluated on the results of the questionnaires. The following information were taken into account: setting where disinfection and sterilization had been performed, preparation of dental equipment for sterilization (disinfection, washing and cleaning, packaging), the types of autoclaves and used types of sterilization cycles, routine monitoring and documentation of sterilization processes, treatment of handpieces and the frequency of surface decontamination. Data were collected from 43 dental practices (35 dental offices and 8 clinics). Disinfection and cleaning processes were performed manually in 63% of dental offices and ultrasonic baths were used in 53% of settings. Washer disinfectors were used in 23% of dental practices: in every researched clinic and in a few dental offices. All sterilization processes were performed in steam autoclaves, mainly in small steam sterilizers (81%). Dental handpieces were sterilized in 72% of practices, but only 33% of them performed sterilization in recommended cycle B. Sterilization processes were monitored with chemical indicators in 33% of practices. Biological monitoring of the processes was carried out at different intervals. Incorrect documentation of instruments and surfaces decontamination was recorded in several settings. There is still a need for improvement of decontamination processes in dental practice in Poland. Areas for improvement include: replacement of manual cleaning and disinfection processes with automatic processes, sterilization of dental handpieces after each patient, monitoring of a sterilization process with chemical and

  3. Studies on induced mutation of sesame male sterility

    International Nuclear Information System (INIS)

    Li Yingde; Feng Xiangyun; Zhao Yingzhong

    2001-01-01

    The dry seeds of the high yielding cultivar, Yuzhi-4, were irradiated with 300, 500 and 700 Gy of 60 Co- gamma rays. 3277 M 1 plants were harvested separately as single plants and also in bulk, by doses. In M 2 , the single plant seeds were grown in progeny rows and the bulked seeds were grown as bulks. 25 male sterile plants were screened from M 2 . 10 of the 25 male sterile plants were from the progenies of the single plant seeds and 15 were from the progenies of the bulked seeds. In further genetic research of the 25 male sterile plants in M 3 and M 4 , 6 separate genic male sterile (GMS) lines were identified. Their male sterility was stable and was controlled by a pair of alleles, male fertility being dominant to sterility. (author)

  4. A see-saw mechanism with light sterile neutrinos

    International Nuclear Information System (INIS)

    McKellar, B.H.J.; Garbutt, M.; Stephenson, G.J.; Goldman, T.

    2001-01-01

    The usual see-saw mechanism for the generation of light neutrino masses is based on the assumption that all of the flavours of right-handed (more properly, sterile) neutrinos are heavy. If the sterile Majorana mass matrix is singular, one or more of the sterile neutrinos will have zero mass before mixing with the active (left-handed) neutrinos and be light after that mixing is introduced In particular, a rank 1 sterile mass matrix leads naturally to two pseudo-Dirac pairs, one very light active Majorana neutrino and one heavy sterile Majorana neutrino. For any pattern of Dirac masses, there exists a region of parameter space in which the two pseudo-Dirac pairs are nearly degenerate in mass. This, in turn, leads to large amplitude mixing of active states as well as mixing into sterile states

  5. Cosmology seeking friendship with sterile neutrinos

    International Nuclear Information System (INIS)

    Hamann, J.; Hannestad, S.; Raffelt, G.G.; Tamborra, I.; Wong, Y.Y.Y.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile neutrino states from the most recent cosmological data. Our results are compatible with the existence of one or perhaps two sterile neutrinos, as suggested by LSND and MiniBooNE, if ms is in the sub-eV range.

  6. Sterilization of solutions for parenterals products. Problem analysis

    Directory of Open Access Journals (Sweden)

    Yanelys Montes-González

    2017-09-01

    Full Text Available The solutions for the formulation of parenteral products must be sterile before the aseptic formulation process. For this reason, different methods of sterilization referred in the literature are analyzed. Thermodynamic criteria that rule the sterilization are presented. Furthermore, previous experiences in the sterilization of solutions for the formulation of parental products in an autoclave are analyzed, that take large time of processing and only low volumes of solution can be handled. Using jacketed stirred tanks for the sterilization may solve the problem and, therefore, criteria for the design of the later that allow to process high volumes of solution for the formulation of parenteral products are shown.

  7. Providing Re-Essure-ance to the Nickel-Allergic Patient Considering Hysteroscopic Sterilization.

    Science.gov (United States)

    Lane, Andrew; Tyson, Adam; Thurston, Erin

    2016-01-01

    Essure is a popular method of permanent sterilization that offers a minimally invasive approach that avoids the risks of traditional sterilization procedures in the operating room. Despite the rarity of complications, there has been concern in the popular media over the safety of Essure. We describe the third reported case of systemic contact dermatitis due to the nickel component of the device, with a resolution of symptoms following surgical removal of the inserts. Despite these cases, we believe that extremely rare complications such as this should not dissuade patients from choosing this safe, effective method of sterilization. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  8. A novel steam explosion sterilization improving solid-state fermentation performance.

    Science.gov (United States)

    Zhao, Zhi-Min; Wang, Lan; Chen, Hong-Zhang

    2015-09-01

    Traditional sterilization of solid medium (SM) requires lengthy time, degrades nutrients, and even sterilizes inadequately compared with that of liquid medium due to its low thermal conductivity. A novel sterilization strategy, high-temperature and short-time steam explosion (SE), was exploited for SM sterilization in this study. Results showed that SE conditions for complete sterilization were 172 °C for 2 min and 128 °C for 5 min. Glucose and xylose contents in medium after SE sterilization increased by 157% and 93% respectively compared with those after conventional sterilization (121 °C, 20 min) while fermentation inhibitors were not detected. FTIR spectra revealed that the mild SE conditions helped to release monosaccharides from the polysaccharides. Bacillus subtilis fermentation productivity on medium after SE sterilization was 3.83 times of that after conventional sterilization. Therefore, SE shortened sterilization time and improved SM nutrition, which facilitated fermentability of SM and should promote economy of solid-state fermentation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Sewage sterilization through gamma radiation

    International Nuclear Information System (INIS)

    Vieira, D.V.; Teixeira, W.M.S.; Silva, F.C.A. da

    2017-01-01

    Lack of sewage treatment and adequate sanitation conditions can contribute to the proliferation of numerous parasitic and infectious diseases in addition to water degradation. Approximately fifty types of infections can be transmitted from a sick to a healthy person through different pathways involving human excreta. Untreated sewage can contaminate water, food, hands, soil, etc. Epidemics of certain diseases such as typhoid, cholera, dysenteries, etc., and countless cases of worms are responsible for high mortality rates in third world countries. In the work the different techniques of sewage treatment by disinfestation and sterilization were analyzed, highlighting the use and the advantages of the gamma radiation as well as the aspects of the radiological protection involved. The technique of sewage sterilization using gamma radiation is a method of controlling bacteria and microorganisms. It is estimated that more than 200 large irradiators are in operation worldwide, of which 5 are in Brazil, for general sterilization use. These facilities use a large amount of radioactive material, in the order of millions of Becquerel, for sterilization with high doses of radiation, which can generate lethal doses in a few minutes. These industrial facilities use Cobalt-60, being classified by the International Atomic Energy Agency - IAEA as Category 1 of high risk, and must possess a high level of radiological protection to carry out the sterilization, standing out the defense in depth. Specific legislation on radiological protection should be drafted for safe work and avoid future radiation accidents

  10. Searching for Sterile Neutrinos with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Timmons, Ashley [Manchester U.

    2016-01-01

    This document presents the latest results for a 3+1 sterile neutrino search using the $10.56 \\times 10^{20}$ protons-on-target data set taken from 2005 - 2012. By searching for oscillations driven by a large mass splitting, MINOS is sensitive to the existence of sterile neutrinos through any energy dependent deviations using a charged current sample, as well as looking at any relative deficit between neutral current events between the far and near detectors. This document will discuss the novel analysis that enabled a search for sterile neutrinos setting a limit in the previously unexplored regions in the parameter space $\\{\\Delta m^{2}_{41}, \\sin^2\\theta_{24}\\}$. The results presented can be compared to the parameter space suggested by LSND and MiniBooNE and complements other previous experimental searches for sterile neutrinos in the electron neutrino appearance channel.

  11. Ionizing radiation for sterilization of medical products and biological tissues

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, S K; Raghevendrarao, M K [Bhabha Atomic Research Centre, Bombay (India). Library and Technical Information Section

    1975-10-01

    The article reviews the deliberations of the International Symposium on Ionizing Radiation for Sterilization of Medical Products and Biological Tissues which was held during 9-13 December 1974 under the auspices of the IAEA at the Bhabha Atomic Research Centre, Bombay. 42 papers were presented in the following broad subject areas: (1) Microbiological Control aspects of radiation sterilization, (2) Dosimetry aspects of radiation sterilization practices, (3) Effects of sterilizing radiation dose on the constituents of medical products, (4) Application of radiation sterilization of medical products of biological origin, (5) Technological aspects of radiation sterilization facilities, (6) Radiation sterilization of pharmaceutical substances, (7) Reports on current status of radiation sterilization of medical products in IAEA member states and (8) Working group discussion on the revision of the IAEA recommended code of practice for radiation sterilization of medical products.

  12. Hysteroscopic sterilization of patient with intrauterine device Mirena®

    Science.gov (United States)

    Depes, Daniella De Batista; Pereira, Ana Maria Gomes; Yatabe, Salete; Lopes, Reginaldo Guedes Coelho

    2013-01-01

    ABSTRACT Tubal sterilization is the definitive procedure most often used worldwide to control fecundity. Laparoscopic ligature is safe, but invasive and with possible surgical and anesthetic risks. The hysteroscopic approach enables tubal occlusion at outpatient's setting without the need of incisions or anesthesia. A microdevice (Essure®) is inserted directly into the tubes and its polyethelene fibers cause obstruction of tubes in about three months. During this period, it is recommended that patients continue the use of a temporary birth control method. Several women use the levonorgestrel-releasing intrauterine system, which is called in the market as Mirena®. This report evaluated the possibility of inserting Essure® without remove the intrauterine device; patient tolerance to the procedure was also assessed. The tubal device was successfully placed in the patient without the need to remove Mirena®. After three months the intrauterine device was removed with no intercurrent events. PMID:23579753

  13. 9 CFR 116.4 - Sterilization and pasteurization -records.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Sterilization and pasteurization... REPORTS § 116.4 Sterilization and pasteurization -records. Records shall be made by means of automatic... ingredients, equipment, or biological product subjected to sterilization or pasteurization. (Approved by the...

  14. [Preliminary Study of Lonicera hypoglauca on Germination Conditions of Sand Culture Seeds and Sterilization Method of Sand Culture Seedling Sterilization].

    Science.gov (United States)

    Tan, Mu-xiu; Zeng, Wen-wen; Wei, Peng-xiao; Mo, Qiao-cheng; Pu, Zu-ning; Cen, Xiu-fen; Shi, Feng-hua

    2015-05-01

    To explore the germination conditions of Lonicera hypoglauca sand culture seeds and the effects of sand culture seedlings sterilization. 0.1% HgCl2 with different sterilization time, different illumination time and temperature culture condition were adopted to study the germination conditions of sand culture seeds. Different sterilization treatments and different hardening-seedling days were used to test the sterilization effect of sand culture seedlings. The sterilization effect of the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min on Lonicera hypoglauca seeds was the optimum,with the average pollution rate of 15.56%, and the average germination rate reached 51.11%. The combination of varied temperature-room temperature under light for 12 h/d was the best, with the average germination rate peaked at 75.49%, and the average germination potential reached 68.36%. The treatment of detergent liquor scrub-tap water wash on the part above the hypocotyl, which was sand cultured under the opening condition and had no root, showed the best sterilization effect, with the average pollution rate was zero, and the average survival rate peaked at 100.00%. The sterilization effect of sand culture seedlings, which was disinfected after cleaning by detergent liquor scrub-tap water wash after hardening-seeding for 30 days, was the best, with the average pollution rate of 50.00%, and the average survival rate of 100.00%. The best sterilization effect is the combination of 75% ethanol 30 s + 0.1% HgCl2 5 min; Lighting for 12 h/d of varied temperature-room temperature is regarded as the optimum culture condition. The treatment of detergent liquor scrub-tap water wash treatment on the part above the hypocotyl,which is sand cultured under the opening condition and had no root, shows the best sterilization effect. For the sand culture seedlings, before inoculated in subculture medium, should be hardening-seedling for some days and sterilized after detergent liquor scrub-tap water wash.

  15. Pharmaceuticals removal and microbial community assessment in a continuous fungal treatment of non-sterile real hospital wastewater after a coagulation-flocculation pretreatment.

    Science.gov (United States)

    Mir-Tutusaus, J A; Parladé, E; Llorca, M; Villagrasa, M; Barceló, D; Rodriguez-Mozaz, S; Martinez-Alonso, M; Gaju, N; Caminal, G; Sarrà, M

    2017-06-01

    Hospital wastewaters are a main source of pharmaceutical active compounds, which are usually highly recalcitrant and can accumulate in surface and groundwater bodies. Fungal treatments can remove these contaminants prior to discharge, but real wastewater poses a problem to fungal survival due to bacterial competition. This study successfully treated real non-spiked, non-sterile wastewater in a continuous fungal fluidized bed bioreactor coupled to a coagulation-flocculation pretreatment for 56 days. A control bioreactor without the fungus was also operated and the results were compared. A denaturing gradient gel electrophoresis (DGGE) and sequencing approach was used to study the microbial community arisen in both reactors and as a result some bacterial degraders are proposed. The fungal operation successfully removed analgesics and anti-inflammatories, and even the most recalcitrant pharmaceutical families such as antibiotics and psychiatric drugs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Ozone--the latest advance in sterilization of medical devices.

    Science.gov (United States)

    Murphy, Lorna

    2006-06-01

    How many times have procedures in your operating rooms been delayed because the instruments needed were still in the sterilizer? As Perioperative nurses you are likely to be quite familiar with the constant pressure to ensure that scarce instrumentation is available when needed. In 2003, a Canadian company developed a unique sterilization process employing ozone as the sterilizing agent. This technology is a safe, rapid and economical alternative to other low temperature sterilization modalities and may relieve some of the pressure experienced when instruments in short supply are in high demand. This article will discuss the principles of the sterilizer and the cycle and will explore the advantages of using this sterilization technology.

  17. Allelic interaction of F1 pollen sterility loci and abnormal chromosome behaviour caused pollen sterility in intersubspecific autotetraploid rice hybrids.

    Science.gov (United States)

    He, J H; Shahid, M Q; Li, Y J; Guo, H B; Cheng, X A; Liu, X D; Lu, Y G

    2011-08-01

    The intersubspecific hybrids of autotetraploid rice has many features that increase rice yield, but lower seed set is a major hindrance in its utilization. Pollen sterility is one of the most important factors which cause intersubspecific hybrid sterility. The hybrids with greater variation in seed set were used to study how the F(1) pollen sterile loci (S-a, S-b, and S-c) interact with each other and how abnormal chromosome behaviour and allelic interaction of F(1) sterility loci affect pollen fertility and seed set of intersubspecific autotetraploid rice hybrids. The results showed that interaction between pollen sterility loci have significant effects on the pollen fertility of autotetraploid hybrids, and pollen fertility further decreased with an increase in the allelic interaction of F(1) pollen sterility loci. Abnormal ultra-structure and microtubule distribution patterns during pollen mother cell (PMC) meiosis were found in the hybrids with low pollen fertility in interphase and leptotene, suggesting that the effect-time of pollen sterility loci interaction was very early. There were highly significant differences in the number of quadrivalents and bivalents, and in chromosome configuration among all the hybrids, and quadrivalents decreased with an increase in the seed set of autotetraploid hybrids. Many different kinds of chromosomal abnormalities, such as chromosome straggling, chromosome lagging, asynchrony of chromosome disjunction, and tri-fission were found during the various developmental stages of PMC meiosis. All these abnormalities were significantly higher in sterile hybrids than in fertile hybrids, suggesting that pollen sterility gene interactions tend to increase the chromosomal abnormalities which cause the partial abortion of male gametes and leads to the decline in the seed set of the autotetraploid rice hybrids. © 2011 The Author(s).

  18. Morphological and genetic characterization of a new cytoplasmic male sterility system (oxa CMS) in stem mustard (Brassica juncea).

    Science.gov (United States)

    Heng, Shuangping; Liu, Sansan; Xia, Chunxiu; Tang, HongYu; Xie, Fei; Fu, Tingdong; Wan, Zhengjie

    2018-01-01

    KEY MESSAGE: oxa CMS is a new cytoplasmic male sterility type in Brassica juncea. oxa CMS is a cytoplasmic male sterility (CMS) line that has been widely used in the production and cultivation of stem mustard in the southwestern China. In this study, different CMS-type specific mitochondrial markers were used to confirm that oxa CMS is distinct from the pol CMS, ogu CMS, nap CMS, hau CMS, tour CMS, Moricandia arvensis CMS, orf220-type CMS, etc., that have been previously reported in Brassica crops. Pollen grains of the oxa CMS line are sterile with a self-fertility rate of almost 0% and the sterility strain rate and sterility degree of oxa CMS is 100% due to a specific flower structure and flowering habit. Scanning electron microscopy revealed that most pollen grains in mature anthers of the oxa CMS line are empty, flat and deflated. Semi-thin section further showed that the abortive stage of anther development in oxa CMS is initiated at the late uninucleate stage. Abnormally vacuolated microspores caused male sterility in the oxa CMS line. This cytological study combined with marker-assisted selection showed that oxa CMS is a novel CMS type in stem mustard (Brassica juncea). Interestingly, the abortive stage of oxa CMS is later than those in other CMS types reported in Brassica crops, and there is no negative effect on the oxa CMS line growth period. This study demonstrated that this novel oxa CMS has a unique flower structure with sterile pollen grains at the late uninucleate stage. Our results may help to uncover the mechanism of oxa CMS in Brassica juncea.

  19. A hydroponic system for growing gnotobiotic vs. sterile plants to study phytoremediation processes.

    Science.gov (United States)

    Kurzbaum, E; Kirzhner, F; Armon, R

    2014-01-01

    In some phytoremediation studies it is desirable to separate and define the specific contribution of plants and root-colonizing bacteria towards contaminant removal. Separating the influence of plants and associated bacteria is a difficult task for soil root environments. Growing plants hydroponically provides more control over the biological factors in contaminant removal. In this study, a hydroponic system was designed to evaluate the role of sterile plant roots, rhizodeposition, and root-associated bacteria in the removal of a model contaminant, phenol. A strain of Pseudomonas pseudoalcaligenes that grows on phenol was inoculated onto plant roots. The introduced biofilm persisted in the root zone and promoted phenol removal over non-augmented controls. These findings indicate that this hydroponic system can be a valuable tool for phytoremediation studies that investigate the effects of biotic and abiotic factors on pollution remediation.

  20. Evaluation of steam sterilization conditions for [18F]fludeoxyglucose

    International Nuclear Information System (INIS)

    Santos, Priscilla F.; Nascimento, Leonardo T.; Valente, Eduardo S.; Silva, Juliana B.; Silveira, Marina B.; Ferreira, Soraya Z.

    2011-01-01

    [ 18 F]Flu deoxyglucose ( 18 FDG) is the most commonly used radiopharmaceutical for positron emission tomography. Sterile filtration of the final product into sterile vials using 0.22 μm filter membrane is usually adopted for 18 FDG. However, Good Manufacturing Practice (GMP) guidelines recommend heat sterilization as the method of choice to ensure sterility of pharmaceutical preparations. The aim of this study was to essay different steam sterilization conditions in order to choose the best one for 18 FDG. Three different sterilization conditions were essayed. The first one at 121 deg C for 15 minutes, the second one at 135 deg C for 3.5 minutes and the third one at 133 deg C for 2 minutes. 18 FDG pH-formulation was kept around 6.0. At the end of autoclave cycles, 18 FDG sterility was evaluated by direct inoculation of 18 FDG in culture media and radiochemical purity was determined by TLC and HPLC. Results demonstrated that all essayed conditions were able to ensure 18 FDG sterility, but caused a decrease in radiochemical purity of 18 FDG. Autoclave cycle at 133 deg C for 2 minutes was the best essayed condition for 18 FDG terminal sterilization, once it provided the greater radiochemical purity value and took less time. 18 FDG was able to meet specifications after autoclave cycles, what supports the application of steam sterilization in routine 18 FDG production, in compliance with GMP. (author)

  1. Degradation of chitosan-based materials after different sterilization treatments

    International Nuclear Information System (INIS)

    San Juan, A; Montembault, A; Royaud, I; David, L; Gillet, D; Say, J P; Rouif, S; Bouet, T

    2012-01-01

    Biopolymers have received in recent years an increasing interest for their potential applications in the field of biomedical engineering. Among the natural polymers that have been experimented, chitosan is probably the most promising in view of its exceptional biological properties. Several techniques may be employed to sterilize chitosan-based materials. The aim of our study was to compare the effect of common sterilization treatments on the degradation of chitosan-based materials in various physical states: solutions, hydrogels and solid flakes. Four sterilization methods were compared: gamma irradiation, beta irradiation, exposure to ethylene oxide and saturated water steam sterilization (autoclaving). Exposure to gamma or beta irradiation was shown to induce an important degradation of chitosan, regardless of its physical state. The chemical structure of chitosan flakes was preserved after ethylene oxide sterilization, but this technique has a limited use for materials in the dry state. Saturated water steam sterilization of chitosan solutions led to an important depolymerization. Nevertheless, steam sterilization of chitosan flakes bagged or dispersed in water was found to preserve better the molecular weight of the polymer. Hence, the sterilization of chitosan flakes dispersed in water would represent an alternative step for the preparation of sterilized chitosan solutions. Alternatively, autoclaving chitosan physical hydrogels did not significantly modify the macromolecular structure of the polymer. Thus, this method is one of the most convenient procedures for the sterilization of physical chitosan hydrogels after their preparation.

  2. Determination of sterilizing dose of lincocine drug

    International Nuclear Information System (INIS)

    Adawi, M.A.; Shamma, M.; Al-Mousa, A.

    1998-01-01

    There are too many antibiotics that have been studied on their dry solid state to determine their safe sterilizing dose by decreasing their bio burden in order to reach the sterility assurance level (SAL) needed. The sterilizing radiating dose of lincocine was determined according to information about their bio burden and radiating sensitivity at the sterility assurance level 10-6. The study of bio burden has shown that the contamination was fungal (Pemicillium sp.) and by applying the same tests to the raw materials of lincocine it came out that the cause of contamination was bad storage and that the radiating dose required to decrease the bio burden was 5.5 kGy. (author)

  3. Hybrid male sterility in rice controlled by interaction between divergent alleles of two adjacent genes.

    Science.gov (United States)

    Long, Yunming; Zhao, Lifeng; Niu, Baixiao; Su, Jing; Wu, Hao; Chen, Yuanling; Zhang, Qunyu; Guo, Jingxin; Zhuang, Chuxiong; Mei, Mantong; Xia, Jixing; Wang, Lan; Wu, Haibin; Liu, Yao-Guang

    2008-12-02

    Sterility is common in hybrids between divergent populations, such as the indica and japonica subspecies of Asian cultivated rice (Oryza sativa). Although multiple loci for plant hybrid sterility have been identified, it remains unknown how alleles of the loci interact at the molecular level. Here we show that a locus for indica-japonica hybrid male sterility, Sa, comprises two adjacent genes, SaM and SaF, encoding a small ubiquitin-like modifier E3 ligase-like protein and an F-box protein, respectively. Most indica cultivars contain a haplotype SaM(+)SaF(+), whereas all japonica cultivars have SaM(-)SaF(-) that diverged by nucleotide variations in wild rice. Male semi-sterility in this heterozygous complex locus is caused by abortion of pollen carrying SaM(-). This allele-specific gamete elimination results from a selective interaction of SaF(+) with SaM(-), a truncated protein, but not with SaM(+) because of the presence of an inhibitory domain, although SaM(+) is required for this male sterility. Lack of any one of the three alleles in recombinant plants does not produce male sterility. We propose a two-gene/three-component interaction model for this hybrid male sterility system. The findings have implications for overcoming male sterility in inter-subspecific hybrid rice breeding.

  4. 7 CFR 305.23 - Steam sterilization treatment schedules.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 5 2010-01-01 2010-01-01 false Steam sterilization treatment schedules. 305.23... Steam sterilization treatment schedules. Treatment schedule Temperature( °F) Pressure Exposure period (minutes) Directions T303-b-1 10 lbs 20 Use 28″ vacuum. Steam sterilization is not practical for treatment...

  5. Retrospective cost analysis comparing Essure hysteroscopic sterilization and laparoscopic bilateral tubal coagulation.

    Science.gov (United States)

    Hopkins, Matthew R; Creedon, Douglas J; Wagie, Amy E; Williams, Arthur R; Famuyide, Abimbola O

    2007-01-01

    To compare the institutional cost of permanent female sterilization by Essure hysteroscopic sterilization and laparoscopic bilateral coagulation. Retrospective cohort study (Canadian Task Force classification II-2). Midwestern academic medical center. Women of reproductive age who elected for permanent contraception by the Essure method (n = 43) or by laparoscopic tubal coagulation (n = 44) during the time frame studied. Placement of the Essure inserts according to the manufacturer's instructions or laparoscopic tubal sterilization using bipolar forceps according to standard techniques of open or closed laparoscopy. Cost-center data for the institutional cost of the procedure was abstracted for each patient included in the study. In addition, demographic data and procedural information were obtained and compared for the patient populations. The Essure system of hysteroscopic sterilization had a significantly decreased cost compared with laparoscopic tubal sterilization when both procedures were performed in an operating room setting. The decrease per patient in institutional cost was 180 dollars (p = .038). This included the cost of the confirmatory hysterosalpingogram 3 months after Essure placement and the cost of laparoscopic tubal occlusion by Filshie clip if the Essure micro-inserts could not be placed. The majority of the cost was related to hospital costs as opposed to physician costs. The Essure procedure had higher costs for disposable equipment (p Essure hysteroscopic sterilization had significant cost savings compared with laparoscopic tubal sterilization (p = .038). We believe that our data represent the minimum of potential savings using this approach, and future developments will only increase the cost difference found in our study.

  6. One-step formation and sterilization of gellan and hyaluronan nanohydrogels using autoclave.

    Science.gov (United States)

    Montanari, Elita; De Rugeriis, Maria Cristina; Di Meo, Chiara; Censi, Roberta; Coviello, Tommasina; Alhaique, Franco; Matricardi, Pietro

    2015-01-01

    The sterilization of nanoparticles for biomedical applications is one of the challenges that must be faced in the development of nanoparticulate systems. Usually, autoclave sterilization cannot be applied because of stability concerns when polymeric nanoparticles are involved. This paper describes an innovative method which allows to obtain, using a single step autoclave procedure, the preparation and, at the same time, the sterilization of self-assembling nanohydrogels (NHs) obtained with cholesterol-derivatized gellan and hyaluronic acid. Moreover, by using this approach, NHs, while formed in the autoclave, can be easily loaded with drugs. The obtained NHs dispersion can be lyophilized in the presence of a cryoprotectant, leading to the original NHs after re-dispersion in water.

  7. Cosmology seeking friendship with sterile neutrinos

    DEFF Research Database (Denmark)

    Hamann, Jan; Hannestad, Steen; Raffelt, G.G.

    2011-01-01

    Precision cosmology and big-bang nucleosynthesis mildly favour extra radiation in the universe beyond photons and ordinary neutrinos, lending support to the existence of low-mass sterile neutrinos. We present bounds on the common mass scale ms and effective number Ns of thermally excited sterile ...

  8. Male sterile mutant in Vigna radiata

    International Nuclear Information System (INIS)

    Pande, Kalpana; Raghuvanshi, S.S.

    1987-01-01

    Single and combined treatment of γ-rays and 0.25 per cent EMS were tried on Vigna radiata variety K851. A male sterile mutant was isolated in M 2 generation. Experiments indicated male sterility to be recessive and monogenic in nature. 6 figures. (author)

  9. Radiation: A means of sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, R N [International Atomic Energy Agency, Division of Life Sciences, Radiation Biology Section, Vienna (Austria)

    1975-12-15

    The sterilization of medical products by ionizing radiation is a well-established industrial process in a number of technologically advanced countries. It is indeed encouraging to note the rate of growth experienced during the past fifteen years. Starting with the first commercial plant in the early sixties in the USA there are to date more than sixty large facilities of this kind located in USA, Canada, Australia and the countries of Europe including USSR. The geographical distribution of these sterilization plants is rather unbalanced. In this respect Europe is far ahead of the other continents of the world, with about 65% of all sterilization plants, followed by North and South America with 17%, Asia with 8%, Australia and New Zealand with 9% and Africa with only 1%. During the last 10 years the IAEA has actively contributed to the development of radiation sterilization practices and technology in the Member States, with particular emphasis on the developing countries. Such promotional efforts have been made by (a) supporting co-ordinated research to accumulate relevant technical information, (b) organizing scientific meetings and training courses, (c) providing technical expertise in the form of fellowships and expert services, (d) providing technical assistance to conduct market surveys and economic feasibility assessment, (e) scientific publications, including technical manuals and proceedings reports, and (f) assistance in the formulation of an international 'Code of Practice' for standardization of the manufacturing practices for radiation sterilized medical products to meet the specified requirements of the various national Pharmacopoeias and of the international consumer market.

  10. Reionization in sterile neutrino cosmologies

    Science.gov (United States)

    Bose, Sownak; Frenk, Carlos S.; Hou, Jun; Lacey, Cedric G.; Lovell, Mark R.

    2016-12-01

    We investigate the process of reionization in a model in which the dark matter is a warm elementary particle such as a sterile neutrino. We focus on models that are consistent with the dark matter decay interpretation of the recently detected line at 3.5 keV in the X-ray spectra of galaxies and clusters. In warm dark matter models, the primordial spectrum of density perturbations has a cut-off on the scale of dwarf galaxies. Structure formation therefore begins later than in the standard cold dark matter (CDM) model and very few objects form below the cut-off mass scale. To calculate the number of ionizing photons, we use the Durham semi-analytic model of galaxy formation, GALFORM. We find that even the most extreme 7 keV sterile neutrino we consider is able to reionize the Universe early enough to be compatible with the bounds on the epoch of reionization from Planck. This, perhaps surprising, result arises from the rapid build-up of high redshift galaxies in the sterile neutrino models which is also reflected in a faster evolution of their far-UV luminosity function between 10 > z > 7 than in CDM. The dominant sources of ionizing photons are systematically more massive in the sterile neutrino models than in CDM. As a consistency check on the models, we calculate the present-day luminosity function of satellites of Milky Way-like galaxies. When the satellites recently discovered in the Dark Energy Survey are taken into account, strong constraints are placed on viable sterile neutrino models.

  11. Revisiting cosmological bounds on sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Vincent, Aaron C. [Institute for Particle Physics Phenomenology (IPPP), Department of Physics, Durham University, Durham DH1 3LE (United Kingdom); Martínez, Enrique Fernández [Departamento and Instituto de Física Teórica (IFT), UAM/CSIC, Universidad Autonoma de Madrid, C/ Nicolás Cabrera 13-15, E-28049 Cantoblanco, Madrid (Spain); Hernández, Pilar; Mena, Olga [Instituto de Física Corpuscular (IFIC), CSIC-Universitat de València, Apartado de Correos 22085, E-46071 Valencia (Spain); Lattanzi, Massimiliano, E-mail: aaron.vincent@durham.ac.uk, E-mail: enrique.fernandez-martinez@uam.es, E-mail: m.pilar.hernandez@uv.es, E-mail: omena@ific.uv.es, E-mail: lattanzi@fe.infn.it [Dipartimento di Fisica e Science della Terra, Università di Ferrara and INFN, sezione di Ferrara, Polo Scientifico e Tecnologico, Edificio C Via Saragat, 1, I-44122 Ferrara (Italy)

    2015-04-01

    We employ state-of-the art cosmological observables including supernova surveys and BAO information to provide constraints on the mass and mixing angle of a non-resonantly produced sterile neutrino species, showing that cosmology can effectively rule out sterile neutrinos which decay between BBN and the present day. The decoupling of an additional heavy neutrino species can modify the time dependence of the Universe's expansion between BBN and recombination and, in extreme cases, lead to an additional matter-dominated period; while this could naively lead to a younger Universe with a larger Hubble parameter, it could later be compensated by the extra radiation expected in the form of neutrinos from sterile decay. However, recombination-era observables including the Cosmic Microwave Background (CMB), the shift parameter R{sub CMB} and the sound horizon r{sub s} from Baryon Acoustic Oscillations (BAO) severely constrain this scenario. We self-consistently include the full time-evolution of the coupled sterile neutrino and standard model sectors in an MCMC, showing that if decay occurs after BBN, the sterile neutrino is essentially bounded by the constraint sin{sup 2}θ ∼< 0.026 (m{sub s}/eV){sup −2}.

  12. Development of cytoplasmic-nuclear male sterility, its inheritance, and potential use in hybrid pigeonpea breeding.

    Science.gov (United States)

    Saxena, Kul B; Ravikoti, V Kumar; Dalvi, Vijay A; Pandey, Lalji B; Gaddikeri, Guruprasad

    2010-01-01

    Pigeonpea [Cajanus cajan (L.) Millsp.] is a unique food legume because of its partial (20-30%) outcrossing nature, which provides an opportunity to breed commercial hybrids. To achieve this, it is essential to have a stable male-sterility system. This paper reports the selection of a cytoplasmic-nuclear male-sterility (CMS) system derived from an interspecific cross between a wild relative of pigeonpea (Cajanus sericeus Benth. ex. Bak.) and a cultivar. This male-sterility source was used to breed agronomically superior CMS lines in early (ICPA 2068), medium (ICPA 2032), and late (ICPA 2030) maturity durations. Twenty-three fertility restorers and 30 male-sterility maintainers were selected to develop genetically diverse hybrid combinations. Histological studies revealed that vacuolation of growing tetrads and persistence of tetrad wall were primary causes of the manifestation of male sterility. Genetic studies showed that 2 dominant genes, of which one had inhibitory gene action, controlled fertility restoration in the hybrids. The experimental hybrids such as TK 030003 and TK 030009 in early, ICPH 2307 and TK 030625 in medium, and TK 030861 and TK 030851 in late maturity groups exhibited 30-88% standard heterosis in multilocation trials.

  13. Acute sterile endophthalmitis following intravitreal bevacizumab: case series

    Directory of Open Access Journals (Sweden)

    Orozco-Hernández A

    2014-09-01

    Full Text Available Axel Orozco-Hernández,1 Ximena Ortega-Larrocea,1 Gustavo Sánchez-Bermúdez,1 Gerardo García-Aguirre,1 Virgilio Morales Cantón,1 Raul Velez-Montoya2 1Retina Department, Asociación para Evitar la Ceguera en México IAP, Mexico City, Mexico; 2Department of Ophthalmology, University of Colorado School of Medicine, Rocky Mountain Lions Eye Institute, Aurora, CO, USA Background: Since the ophthalmological community adopted the use of intravitreal bevacizumab as an accepted off-label treatment for neovascular diseases, the amount of knowledge regarding its effects and properties has been increasing continually. In the last few years, there have been an increasing number of reports about sterile intraocular inflammation and intraocular pressure elevations after intravitreal bevacizumab. In the following case series, we describe the clinical presentation and outcomes of ten consecutive cases of patients developing mild-to-severe sterile intraocular inflammation after intravitreal bevacizumab and their management. Methods: This report presents a retrospective case series. We reviewed the medical records of ten consecutive patients from a group of 46, in whom repackaged bevacizumab in individual aliquots from two vials from the same batch were used. All surgical procedures were performed using standard sterile techniques in the operating room. At each follow-up visit, patients underwent a complete ophthalmological examination including visual acuity assessment, intraocular pressure, biomicroscopy, and posterior fundus examination. Results: Ten patients presented sterile endophthalmitis with an onset time of 3.5±1.95 days. The clinical characteristics were mild pain, slight visual loss, conjunctival hyperemia, and various degrees of intraocular inflammation with microhypopyon. All cultures were negative. All patients were managed with topical steroids and antibiotics, except two, in whom, due to severe vitreous cells, intravitreal antibiotics were

  14. The sterile immune response during hepatic ischemia/reperfusion

    NARCIS (Netherlands)

    van Golen, Rowan F.; van Gulik, Thomas M.; Heger, Michal

    2012-01-01

    Hepatic ischemia and reperfusion elicits an immune response that lacks a microbial constituent yet poses a potentially lethal threat to the host. In this sterile setting, the immune system is alarmed by endogenous danger signals that are release by stressed and dying liver cells. The detection of

  15. Comparison of postoperative surgical site infection after preoperative marking done with non-sterile stationary grade markers versus sterile surgical markers

    International Nuclear Information System (INIS)

    Mir, Z.A.

    2015-01-01

    Objectives: To compare the frequencies of post- operative surgical site infection after preoperative marking done with non-sterile stationary. grade markers versus sterile surgical markers in the same patient. Design: Randomized control trial. Place and Duration of Study: The department of Plastic surgery, Mayo hospital, Lahore from August 2013 to August 2014. Methods: This study was conducted after taking approval from the departmental ethical committee. Forty consecutive patients were included. A sterile surgical marker was used to mark one incision site while an alcohol based stationary grade marker was used to mark another incision site on the same patient. A standard preoperative, intraoperative and postoperative protocol was followed. Cultures were performed on swabs taken from the incision sites and surgical site infection was assessed for 30 days. Results: The study included 40 patients; 17 males and 23 females. The mean age of subjects was 25.32 ± 19.69 years with the minimum age being 2 years and the maximum being 63 years. No growth was seen in cultures taken from all the incision sites after skin preparation in the non sterile stationary grade marker group as well as the sterile surgical grade marker group. Also no surgical site infection appeared during the 30 day postoperative observation period in the non sterile stationary grade marker group as well as the sterile surgical grade marker group. (author)

  16. Light Sterile Neutrinos: A White Paper

    DEFF Research Database (Denmark)

    Abazajian, K. N.; Acero, M. A.; Agarwalla, S. K.

    2012-01-01

    This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.......This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data....

  17. Impediment to symbiosis establishment between giant clams and Symbiodinium algae due to sterilization of seawater.

    Science.gov (United States)

    Kurihara, Takeo; Yamada, Hideaki; Inoue, Ken; Iwai, Kenji; Hatta, Masayuki

    2013-01-01

    To survive the juvenile stage, giant clam juveniles need to establish a symbiotic relationship with the microalgae Symbiodinium occurring in the environment. The percentage of giant clam juveniles succeeding in symbiosis establishment ("symbiosis rate") is often low, which is problematic for seed producers. We investigated how and why symbiosis rates vary, depending on whether giant clam seeds are continuously reared in UV treated or non treated seawater. Results repeatedly demonstrated that symbiosis rates were lower for UV treated seawater than for non treated seawater. Symbiosis rates were also lower for autoclaved seawater and 0.2-µm filtered seawater than for non treated seawater. The decreased symbiosis rates in various sterilized seawater suggest the possibility that some factors helping symbiosis establishment in natural seawater are weakened owing to sterilization. The possible factors include vitality of giant clam seeds, since additional experiments revealed that survival rates of seeds reared alone without Symbiodinium were lower in sterilized seawater than in non treated seawater. In conclusion, UV treatment of seawater was found to lead to decreased symbiosis rates, which is due possibly to some adverse effects common to the various sterilization techniques and relates to the vitality of the giant clam seeds.

  18. 21 CFR 880.6860 - Ethylene oxide gas sterilizer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ethylene oxide gas sterilizer. 880.6860 Section... Miscellaneous Devices § 880.6860 Ethylene oxide gas sterilizer. (a) Identification. An ethylene gas sterilizer is a nonportable device intended for use by a health care provider that uses ethylene oxide (ETO) to...

  19. Expression of a pathogen-induced cysteine protease (AdCP) in tapetum results in male sterility in transgenic tobacco.

    Science.gov (United States)

    Shukla, Pawan; Singh, Naveen Kumar; Kumar, Dilip; Vijayan, Sambasivam; Ahmed, Israr; Kirti, Pulugurtha Bharadwaja

    2014-06-01

    Usable male sterility systems have immense potential in developing hybrid varieties in crop plants, which can also be used as a biological safety containment to prevent horizontal transgene flow. Barnase-Barstar system developed earlier was the first approach to engineer male sterility in plants. In an analogous situation, we have evolved a system of inducing pollen abortion and male sterility in transgenic tobacco by expressing a plant gene coding for a protein with known developmental function in contrast to the Barnase-Barstar system, which deploys genes of prokaryotic origin, i.e., from Bacillus amyloliquefaciens. We have used a plant pathogen-induced gene, cysteine protease for inducing male sterility. This gene was identified in the wild peanut, Arachis diogoi differentially expressed when it was challenged with the late leaf spot pathogen, Phaeoisariopsis personata. Arachis diogoi cysteine protease (AdCP) was expressed under the strong tapetum-specific promoter (TA29) and tobacco transformants were generated. Morphological and histological analysis of AdCP transgenic plants showed ablated tapetum and complete pollen abortion in three transgenic lines. Furthermore, transcript analysis displayed the expression of cysteine protease in these male sterile lines and the expression of the protein was identified in western blot analysis using its polyclonal antibody raised in the rabbit system.

  20. Sterilization of fruit flies (Diptera: Tephritidae) with X-rays for sterile insect technique programs

    International Nuclear Information System (INIS)

    Mastrangelo, Thiago de Araujo

    2009-01-01

    Recent fear of acts of terrorism provoked an increase of delays and denials in the shipment of radioisotopes. This truly represented a menace to sterile insect production projects around the world. In order to validate the use of a new kind of low-energy Xray irradiator, a series of radiobiological studies on Ceratitis capitata (tsl-VIENNA 8 strain) (Wied., 1824) (Diptera: Tephritidae) and an Argentinean strain of Anastrepha fraterculus (Wied., 1830) (Diptera: Tephritidae) were carried out, also comparing biological effectiveness between X-rays and traditional γ radiation from 60 Co. Pupae 48- 24 h before adult emergence of C. capitata males and both sexes of A. fraterculus were irradiated with doses ranging from 15 to 120 Gy and 10 to 70 Gy respectively. Doses that induce 50, 90 and 99% of sterility were estimated and the hypothesis of Parallelism for the Probit equations was tested. Doses of 82.7 Gy of X-rays and 128.2 Gy of γ rays (thus, a RBE∼1.5) induced 99% sterility on medfly males. The fertility of A. fraterculus fertile females crossed with 41 Gy of X-rays and 62.7 Gy of γ rays decreased in 99% comparing with the control group (RBE∼1.5). 99% sterility of A. fraterculus irradiated females was achieved with 60-80 Gy (RBE∼0.7). The standard quality control parameters of fecundity, adult emergence, fliers and survival were not significantly affected by the two types of radiation (RBE∼1) either for medfly or A. fraterculus (p>0.01), being averages in conformity with the values required by FAO/IAEA/USDA. Only fecundity of irradiated A. fraterculus females was severely reduced with increasing doses and no egg was laid at 70 Gy of both radiations. There were no significant differences between X-rays and γ rays regarding mating indices (RSI for medfly, RII, ISI, MRPI and FRPI for A. fraterculus) (p>0.05), what indicated more random matings for fertile and sterile insects. The results demonstrated that no significant difference in biological

  1. Sterilization of Lung Matrices by Supercritical Carbon Dioxide.

    Science.gov (United States)

    Balestrini, Jenna L; Liu, Angela; Gard, Ashley L; Huie, Janet; Blatt, Kelly M S; Schwan, Jonas; Zhao, Liping; Broekelmann, Tom J; Mecham, Robert P; Wilcox, Elise C; Niklason, Laura E

    2016-03-01

    Lung engineering is a potential alternative to transplantation for patients with end-stage pulmonary failure. Two challenges critical to the successful development of an engineered lung developed from a decellularized scaffold include (i) the suppression of resident infectious bioburden in the lung matrix, and (ii) the ability to sterilize decellularized tissues while preserving the essential biological and mechanical features intact. To date, the majority of lungs are sterilized using high concentrations of peracetic acid (PAA) resulting in extracellular matrix (ECM) depletion. These mechanically altered tissues have little to no storage potential. In this study, we report a sterilizing technique using supercritical carbon dioxide (ScCO2) that can achieve a sterility assurance level 10(-6) in decellularized lung matrix. The effects of ScCO2 treatment on the histological, mechanical, and biochemical properties of the sterile decellularized lung were evaluated and compared with those of freshly decellularized lung matrix and with PAA-treated acellular lung. Exposure of the decellularized tissue to ScCO2 did not significantly alter tissue architecture, ECM content or organization (glycosaminoglycans, elastin, collagen, and laminin), observations of cell engraftment, or mechanical integrity of the tissue. Furthermore, these attributes of lung matrix did not change after 6 months in sterile buffer following sterilization with ScCO2, indicating that ScCO2 produces a matrix that is stable during storage. The current study's results indicate that ScCO2 can be used to sterilize acellular lung tissue while simultaneously preserving key biological components required for the function of the scaffold for regenerative medicine purposes.

  2. Cleaning, disinfection and sterilization of surface prion contamination.

    Science.gov (United States)

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  3. Production of a sterile species: Quantum kinetics

    Science.gov (United States)

    Boyanovsky, D.; Ho, C. M.

    2007-10-01

    Production of a sterile species is studied within an effective model of active-sterile neutrino mixing in a medium in thermal equilibrium. The quantum kinetic equations for the distribution functions and coherences are obtained from two independent methods: the effective action and the quantum master equation. The decoherence time scale for active-sterile oscillations is τdec=2/Γaa, but the evolution of the distribution functions is determined by the two different time scales associated with the damping rates of the quasiparticle modes in the medium: Γ1=Γaacos⁡2θm; Γ2=Γaasin⁡2θm where Γaa is the interaction rate of the active species in the absence of mixing and θm the mixing angle in the medium. These two time scales are widely different away from Mikheyev-Smirnov-Wolfenstein resonances and preclude the kinetic description of active-sterile production in terms of a simple rate equation. We give the complete set of quantum kinetic equations for the active and sterile populations and coherences and discuss in detail the various approximations. A generalization of the active-sterile transition probability in a medium is provided via the quantum master equation. We derive explicitly the usual quantum kinetic equations in terms of the “polarization vector” and show their equivalence to those obtained from the quantum master equation and effective action.

  4. Induction of male sterility in rice using chemical mutagens

    Energy Technology Data Exchange (ETDEWEB)

    Minocha, J L; Gupta, R K [Department of Genetics, Punjab Agricultural University, Ludhiana (India)

    1988-07-01

    Full text: To diversify the sources of cytoplasmic male sterility for hybrid seed production in rice (Oryza sativa L.) attempts were made to induce this character in a popular indica cultivar PR 106 through chemical mutagens. Seeds were treated with 0.4% ethidium bromide (EB) for 24 or 48h at 10 deg. C, with 0.4% ethyl methanesulphonate (EMS) for 24 or 48h at 10 deg. C for 16 hr at 20 deg. C or with 0.2% streptomycin sulphate (SM) for 24 or 48 hr at 10 deg. C. In M{sub 2} male sterile plants were detected in eleven different progenies, one from SM treatment and the remaining from EMS treatments. All the sterile plants had 100% non-stainable aborted pollen. Seed set upon open-pollination of the male sterile plants with the variety PR 106 ranged from 0.03 to 4.93 per cent whereas no seed formed in bagged panicles. In M{sub 3}, open-pollinated progenies of the male sterile plants and their fertile sibs were further studied. Two progenies segregated for male sterility, all others had only fertile plants. In one of the segregating progenies, five out of six and in the other nine out of fourteen plants were male sterile. The progenies of fertile sibs did not have any male sterile plant. The results indicate that sterility of cytoplasmic type has been induced by EMS. The parental variety PR 106 acts as the maintainer. (author)

  5. Induction of male sterility in rice using chemical mutagens

    International Nuclear Information System (INIS)

    Minocha, J.L.; Gupta, R.K.

    1988-01-01

    Full text: To diversify the sources of cytoplasmic male sterility for hybrid seed production in rice (Oryza sativa L.) attempts were made to induce this character in a popular indica cultivar PR 106 through chemical mutagens. Seeds were treated with 0.4% ethidium bromide (EB) for 24 or 48h at 10 deg. C, with 0.4% ethyl methanesulphonate (EMS) for 24 or 48h at 10 deg. C for 16 hr at 20 deg. C or with 0.2% streptomycin sulphate (SM) for 24 or 48 hr at 10 deg. C. In M 2 male sterile plants were detected in eleven different progenies, one from SM treatment and the remaining from EMS treatments. All the sterile plants had 100% non-stainable aborted pollen. Seed set upon open-pollination of the male sterile plants with the variety PR 106 ranged from 0.03 to 4.93 per cent whereas no seed formed in bagged panicles. In M 3 , open-pollinated progenies of the male sterile plants and their fertile sibs were further studied. Two progenies segregated for male sterility, all others had only fertile plants. In one of the segregating progenies, five out of six and in the other nine out of fourteen plants were male sterile. The progenies of fertile sibs did not have any male sterile plant. The results indicate that sterility of cytoplasmic type has been induced by EMS. The parental variety PR 106 acts as the maintainer. (author)

  6. Sterilization and disinfection: the prevailing indifference

    International Nuclear Information System (INIS)

    Mirza, I.

    2007-01-01

    To evaluate the knowledge and attitude of health care professionals towards the process of sterilization and disinfection, and to check the adequacy of the reading material accessible to them. The study comprised of three components. In the first part, sections devoted to this subject in the popular books read by the students of operation theatre assistant course and students of diploma in general nursing were examined for adequacy and authenticity of information. In the second part, standard operating procedures were examined regarding sterilization of textile, rubber tubes of suction units and diathermy hand pieces of 20 operation theatres of three teaching hospital attached to undergraduate medical college of Punjab. In the third part of the study, working knowledge of 64 practicing operation theatre assistants and 57 practicing nurses was assessed through a questionnaire. It was found that popular books either did not contain the required information or the information provided was misleading or incorrect. Standard operating procedures for sterilization of selected items of all the operation theatres studied fell much below the standard of practice desired in the light of current knowledge and contemporary practices. Finally the working knowledge of the professionals studied was much below the bare minimum expected by the profession. There is a dire need for upgrading the knowledge and attitude of health care professionals regarding sterilization, besides improving the operation theatres sterilization procedures. (author)

  7. Female Sterilization and Poor Mental Health: Rates and Relatedness among American Indian and Alaska Native Women.

    Science.gov (United States)

    Cackler, Christina J J; Shapiro, Valerie B; Lahiff, Maureen

    2016-01-01

    To describe the reproductive and mental health of American Indian and Alaska Native (AI/AN) women, an understudied population. Data from the 2004 Behavioral Risk Factor Surveillance System survey were analyzed to determine the 1) prevalence of female sterilization among a nationally representative sample of reproductive age AI/AN women and 2) the association of female sterilization and poor mental health among AI/AN women compared with non-Hispanic White, non-Hispanic Black, and Hispanic women. Nearly 25% of AI/AN women reported female sterilization, a prevalence higher than the comparison racial/ethnic groups (p women reporting female sterilization had nearly 2.5 times the odds of poor mental health compared with AI/AN women not reporting female sterilization (p = .001). The same magnitude of relationship between female sterilization and poor mental health was not found for non-Hispanic White, non-Hispanic Black, and Hispanic women. The prevalence of female sterilization is greater among AI/AN women compared with non-Hispanic White, non-Hispanic Black, and Hispanic women, and AI/AN women reporting female sterilization have higher odds of reporting poor mental health. Common cultural experiences, such as a shared ancestral history of forced sterilizations, may be relevant, and could be considered when providing reproductive and mental health services to AI/AN women. Copyright © 2016 Jacobs Institute of Women's Health. Published by Elsevier Inc. All rights reserved.

  8. Pink bollworm integrated management using sterile insects under field trial conditions, Imperial Valley, California

    International Nuclear Information System (INIS)

    Walters, M.L.; Staten, R.T.; Roberson, R.C.

    2000-01-01

    The pink bollworm moth (Pectinophora gossypiella Saunders) feeds almost exclusively on cotton (Gossypium spp.) and causes economic loss (Pfadt 1978). The pink bollworm (PBW) is often the key pest of cotton in Arizona, southern California, and northwestern Mexico. The larvae (immature stages) bore into the developing cotton fruit, where they feed on the cotton lint and seeds, causing significant damage and dramatically reducing the yield of cotton lint (Pfadt 1978). The PBW is difficult to control with conventional means (insecticides) because it spends the destructive larval phase inside the cotton boll where it is well protected from control measures. Cultural controls, such as a short growing season, have successfully decreased the population in the Imperial Valley (Chu et al. 1992) to the point where eradication may be possible using sterile insects and genetically engineered cotton. Because the PBW is an introduced insect, with few plant hosts other than cultivated cotton, its eradication from continental USA is a desirable and economically attractive alternative to the continued use of pesticides and/or further loss to the pest. Mass releases of sterile insects began in earnest in 1970 in the San Joaquin Valley, California, in order to inhibit normal reproduction and to eradicate the pest in an environmentally responsible manner. Sterile release involves mass production and sexual sterilisation using irradiation (20 krad for PBW adults). This was accomplished by building a rearing facility in Phoenix, AZ. The facility has 6,410 square metres of permanent laboratories, rearing and irradiation chambers and insect packing rooms. The facility operates the year round but with a variable production rate, that is, maximal during the cotton growing season (May through September). Sterile insect technology is based on the monitoring of the native and sterile populations in the field and the subsequent release of appropriate numbers of sterile insects in order to

  9. Sterilization processes. Meeting the demands of today's health care technology.

    Science.gov (United States)

    Crow, S

    1993-09-01

    Universal Precautions dictate sterilization for all invasive equipment that break the blood barrier; however, current methods of sterilization, such as steam and ethylene oxide gas (ETO), are not compatible with many of the delicate, heat-sensitive surgical instruments used in modern health care. In addition, traditional sterilization methods are often too time consuming for practical use in the operating room. Clearly, new sterilization processes need to be developed. In this article, the criteria modern sterilization processes must meet and how some manufacturers plan to meet this challenge are discussed. In addition, the pros and cons of using peracetic acid (the newest sterilization process currently available) are examined.

  10. Improvement on the productivity of continuous tequila fermentation by Saccharomyces cerevisiae of Agave tequilana juice with supplementation of yeast extract and aeration.

    Science.gov (United States)

    Hernández-Cortés, Guillermo; Valle-Rodríguez, Juan Octavio; Herrera-López, Enrique J; Díaz-Montaño, Dulce María; González-García, Yolanda; Escalona-Buendía, Héctor B; Córdova, Jesús

    2016-12-01

    Agave (Agave tequilana Weber var. azul) fermentations are traditionally carried out employing batch systems in the process of tequila manufacturing; nevertheless, continuous cultures could be an attractive technological alternative to increase productivity and efficiency of sugar to ethanol conversion. However, agave juice (used as a culture medium) has nutritional deficiencies that limit the implementation of yeast continuous fermentations, resulting in high residual sugars and low fermentative rates. In this work, fermentations of agave juice using Saccharomyces cerevisiae were put into operation to prove the necessity of supplementing yeast extract, in order to alleviate nutritional deficiencies of agave juice. Furthermore, continuous fermentations were performed at two different aeration flow rates, and feeding sterilized and non-sterilized media. The obtained fermented musts were subsequently distilled to obtain tequila and the preference level was compared against two commercial tequilas, according to a sensorial analysis. The supplementation of agave juice with air and yeast extract augmented the fermentative capacity of S. cerevisiae S1 and the ethanol productivities, compared to those continuous fermentations non supplemented. In fact, aeration improved ethanol production from 37 to 40 g L(-1), reducing sugars consumption from 73 to 88 g L(-1) and ethanol productivity from 3.0 to 3.2 g (Lh)(-1), for non-aerated and aerated (at 0.02 vvm) cultures, respectively. Supplementation of yeast extract allowed an increase in specific growth rate and dilution rates (0.12 h(-1), compared to 0.08 h(-1) of non-supplemented cultures), ethanol production (47 g L(-1)), reducing sugars consumption (93 g L(-1)) and ethanol productivity [5.6 g (Lh)(-1)] were reached. Additionally, the effect of feeding sterilized or non-sterilized medium to the continuous cultures was compared, finding no significant differences between both types of cultures. The overall effect

  11. Genetic technologies to enhance the Sterile Insect Technique (SIT)

    International Nuclear Information System (INIS)

    Alphey, Luke; Baker, Pam; Condon, George C.; Condon, Kirsty C.; Dafa'alla, Tarig H.; Fu, Guoliang; Jin, Li; Labbe, Genevieve; Morrison, Neil M.; Nimmo, Derric D.; O'Connell, Sinead; Phillips, Caroline E.; Plackett, Andrew; Scaife, Sarah; Woods, Alexander; Burton, Rosemary S.; Epton, Matthew J.; Gong, Peng

    2006-01-01

    The Sterile Insect Technique (SIT) has been used very successfully against range of pest insects, including various tephritid fruit flies, several moths and a small number of livestock pests. However, modern genetics could potentially provide several improvements that would increase the cost-effectiveness of SIT, and extend the range of suitable species. These include improved identification of released individuals by incorporation of a stable, heritable, genetic marker; built-in sex separation (genetic sexing); reduction of the hazard posed by non-irradiated accidental releases from mass-rearing facility (fail-safe); elimination of the need for sterilization by irradiation (genetic sterilization). We discuss applications of these methods and the state of the art, at the time of this meeting, in developing suitable strains. We have demonstrated, in several key pest species, that the required strains can be constructed by introducing a repressible dominant lethal genetic system, a method known as RIDL(trade mark). Based on field experience with Medfly, incorporation of a genetic sexing system into SIT programs for other tephritids could potentially provide a very significant improvement in cost-effectiveness. We have now been able to make efficient female-lethal strains for Medfly. One advantage of our approach is that it should be possible rapidly to extend this technology to other fruit fly species; indeed we have recently been able also to make genetic sexing strains of Medfly (Anastrepha ludens). (author)

  12. Genetic technologies to enhance the Sterile Insect Technique (SIT)

    Energy Technology Data Exchange (ETDEWEB)

    Alphey, Luke; Baker, Pam; Condon, George C; Condon, Kirsty C; Dafa' alla, Tarig H; Fu, Guoliang; Jin, Li; Labbe, Genevieve; Morrison, Neil M; Nimmo, Derric D; O' Connell, Sinead; Phillips, Caroline E; Plackett, Andrew; Scaife, Sarah; Woods, Alexander [Oxitec Ltd., Oxford (United Kingdom); Burton, Rosemary S; Epton, Matthew J; Gong, Peng [University of Oxford (United Kingdom). Dept. of Zoology

    2006-07-01

    The Sterile Insect Technique (SIT) has been used very successfully against range of pest insects, including various tephritid fruit flies, several moths and a small number of livestock pests. However, modern genetics could potentially provide several improvements that would increase the cost-effectiveness of SIT, and extend the range of suitable species. These include improved identification of released individuals by incorporation of a stable, heritable, genetic marker; built-in sex separation (genetic sexing); reduction of the hazard posed by non-irradiated accidental releases from mass-rearing facility (fail-safe); elimination of the need for sterilization by irradiation (genetic sterilization). We discuss applications of these methods and the state of the art, at the time of this meeting, in developing suitable strains. We have demonstrated, in several key pest species, that the required strains can be constructed by introducing a repressible dominant lethal genetic system, a method known as RIDL(trade mark). Based on field experience with Medfly, incorporation of a genetic sexing system into SIT programs for other tephritids could potentially provide a very significant improvement in cost-effectiveness. We have now been able to make efficient female-lethal strains for Medfly. One advantage of our approach is that it should be possible rapidly to extend this technology to other fruit fly species; indeed we have recently been able also to make genetic sexing strains of Medfly (Anastrepha ludens). (author)

  13. Hysteroscopic tubal sterilization: a health economic literature review.

    Science.gov (United States)

    2013-01-01

    Hysteroscopic sterilization is a minimally invasive alternative to laparoscopic tubal ligation for women who want permanent contraception. In contrast to the laparoscopic technique, a hysteroscope is used to pass permanent microinserts through the cervix and place them in the fallopian tubes. This procedure does not require local or general anesthesia and can be performed in an office setting. The objective of this analysis was to determine, based on published literature, the cost-effectiveness of hysteroscopic tubal sterilization (HS) compared with laparoscopic tubal ligation (LS) for permanent female sterilization. A systematic literature search was conducted for studies published between January 1, 2008, and December 11, 2012. Potentially relevant studies were identified based on the title and abstract. Cost-utility analyses (studies that report outcomes in terms of costs and quality-adjusted life-years) were prioritized for inclusion. When not available, cost-effectiveness, cost-benefit, and cost-consequence analyses were considered. Costing studies were considered in the absence of all other analyses. A total of 33 abstracts were identified. Three cost analyses were included. A retrospective chart review from Canada found that HS was $111 less costly than LS; a prospective activity-based cost management study from Italy reported that it was €337 less costly than LS; and the results of an American decision model showed that HS was $1,178 less costly than LS. All studies had limited applicability to the Ontario health care system due to differences in setting, resource use, and costs. Three cost analyses found that, although the HS procedure was more expensive due to the cost of the microinserts, HS was less costly than LS overall due to the shorter recovery time required. Hysteroscopic sterilization is a minimally invasive alternative to conventional tubal ligation for women who want a permanent method of contraception. Both approaches involve closing off the

  14. Studies on the ecology of insects sterilized artificially (gamma radiation), 7

    International Nuclear Information System (INIS)

    Kiyoku, Masao; Tsukuda, Ritsuko

    1974-01-01

    Larvae of an oriental fruit fly line introduced, from Amami-Oshima island were reared using an artificial medium prepared with the base ingredient as corn-flour. When pupae were irradiated with a dose of 8 kR from the 137 Cs as gamma-rays source two days before emerging, both male and female adults emerged showed complete sterility. Percentage in emergence, however, was not significantly reduced. In an experiment that two hundred sterilized plus ten normal males were confined with ten normal females in a mating cage, the sterilized males were fully competitive with normal ones in mating to the normal females. Longevity of the sterilized adult males, however, tended to be slightly shorter than that of the normal ones when compared in the survival curves. When less than one hundred and fifty sterilized males were confined, however, few larvae were able to grow to adults. These progeny adult males and females showed the inherited sterility. When dose was 6 kR there was neither significant difference in the longevity between sterilized and normal adults, nor the complete sterility. Besides, the inherited sterility in offspring was not shown clearly. When more than two hundred sterilized plus ten normal males were combined with ten normal females, however, a considerable sterility was found. Causes of the sterility were investigated by dissection of the testes and spermathecae in females mated with 8 kR-sterilized males. (author)

  15. Current Sterilization Protocols-An Orthodontic Perspective

    Directory of Open Access Journals (Sweden)

    Abraham Vinod Korath

    2010-01-01

    Part I of this article focuses on the working principles of various methods of sterilization with an appraisalof their effects on orthodontic instruments. Additionally,contributory factors of instrument damage is enumerated to emphasis the importance of adhering to precise protocols and manufacturer recommendations as well as in alleviating some misconceptions about sterilization induced instrument damage.

  16. Applying the sterile insect technique to the control of insect pests

    International Nuclear Information System (INIS)

    LaChance, L.E.; Klassen, W.

    1991-01-01

    The sterile insect technique involves the mass-rearing of insects, which are sterilized by gamma rays from a 60 Co source before being released in a controlled fashion into nature. Matings between the sterile insects released and native insects produce no progeny, and so if enough of these matings occur the pest population can be controlled or even eradicated. A modification of the technique, especially suitable for the suppression of the moths and butterflies, is called the F, or inherited sterility method. In this, lower radiation doses are used such that the released males are only partially sterile (30-60%) and the females are fully sterile. When released males mate with native females some progeny are produced, but they are completely sterile. Thus, full expression of the sterility is delayed by one generation. This article describes the use of the sterile insect technique in controlling the screwworm fly, the tsetse fly, the medfly, the pink bollworm and the melon fly, and of the F 1 sterility method in the eradication of local gypsy moth infestations. 18 refs, 5 figs, 1 tab

  17. Present studies on the radio-sterilized drugs

    International Nuclear Information System (INIS)

    Marciniec, B.; Dettlaff, K.

    2007-01-01

    Lecture presents present status of radiosterilization of drugs and medical materials as compared to other sterilization methods. Literature review is shown on degradation of different kinds of drugs sterilized upon action of the sterilising doses of radiation

  18. Dark matter relic abundance and light sterile neutrinos

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Yi-Lei [Center for High Energy Physics,Peking University, Beijing 100871 (China); Zhu, Shou-hua [Center for High Energy Physics,Peking University, Beijing 100871 (China); Institute of Theoretical Physics & State Key Laboratory of Nuclear Physics and Technology,Peking University, Beijing 100871 (China); Collaborative Innovation Center of Quantum Matter,Beijing 100871 (China)

    2017-01-09

    In this paper, we calculate the relic abundance of the dark matter particles when they can annihilate into sterile neutrinos with the mass ≲100 GeV in a simple model. Unlike the usual standard calculations, the sterile neutrino may fall out of the thermal equilibrium with the thermal bath before the dark matter freezes out. In such a case, if the Yukawa coupling y{sub N} between the Higgs and the sterile neutrino is small, this process gives rise to a larger Ω{sub DM}h{sup 2} so we need a larger coupling between the dark matter and the sterile neutrino for a correct relic abundance.

  19. Development of a new water sterilization device with a 365 nm UV-LED.

    Science.gov (United States)

    Mori, Mirei; Hamamoto, Akiko; Takahashi, Akira; Nakano, Masayuki; Wakikawa, Noriko; Tachibana, Satoko; Ikehara, Toshitaka; Nakaya, Yutaka; Akutagawa, Masatake; Kinouchi, Yohsuke

    2007-12-01

    Ultraviolet (UV) irradiation is an effective disinfection method. In sterilization equipment, a low-pressure mercury lamp emitting an effective germicidal UVC (254 nm) is used as the light source. However, the lamp, which contains mercury, must be disposed of at the end of its lifetime or following damage due to physical shock or vibration. We investigated the suitability of an ultraviolet light-emitting diode at an output wavelength of 365 nm (UVA-LED) as a sterilization device, comparing with the other wavelength irradiation such as 254 nm (a low-pressure mercury lam) and 405 nm (LED). We used a commercially available UVA-LED that emitted light at the shortest wavelength and at the highest output energy. The new sterilization system using the UVA-LED was able to inactivate bacteria, such as Escherichia coli DH5 alpha, Enteropathogenic E. coli, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella enterica serovar Enteritidis. The inactivations of the bacteria were dependent on the accumulation of UVA irradiation. Taking advantage of the safety and compact size of LED devices, we expect that the UVA-LED sterilization device can be developed as a new type of water sterilization device.

  20. Biochemical Contributions to Corrosion of Carbon Steel and Alloy 22 in a Continual Flow System

    International Nuclear Information System (INIS)

    Horn, J.; Martin, S.; Masterson, B.; Lian, T.

    1998-01-01

    Microbiologically influenced corrosion (MIC) may decrease the functional lifetime of nuclear waste packaging materials in the potential geologic repository at Yucca Mountain (YM), Nevada. Biochemical contributions to corrosion of package materials are being determined in reactors containing crushed repository-site rock with the endogenous microbial community, and candidate waste package materials. These systems are being continually supplied with simulated ground water. Periodically, bulk chemistries are analyzed on the system outflow, and surfacial chemistries are assessed on withdrawn material coupons. Both Fe and Mn dissolved from C1020 coupons under conditions that included the presence of YM microorganisms. Insoluble corrosion products remained in a reduced state at the coupon surface, indicating at least a localized anoxic condition; soluble reduced Mn and Fe were also detected in solution, while precipitated and spalled products were oxidized. Alloy 22 surfaces showed a layer of chrome oxide, almost certainly in the Cr(III) oxidation state, on microcosm-exposed coupons, while no soluble chrome was detected in solution. The results of these studies will be compared to identical testing on systems containing sterilized rock to generate, and ultimately predict, microbial contributions to waste package corrosion chemistries

  1. submitter Prospects of Sterile Neutrino Search with the FCC-ee

    CERN Document Server

    Bay Nielsen, Sissel

    A proposed future circular e + e − collider, the FCC-ee, is suggested to search for sterile neutrinos. The Neutrino Minimal Standard Model, νMSM, is a model of sterile neutrinos, that accommodates explanations for several phenomena of physics beyond the Standard Model. This thesis presents an overview of the theoretical motivation for νMSM, an outline of the experimental conditions at the FCC-ee, and a review of previous accelerator bounds for sterile neutrinos. Two studies of sterile neutrinos with masses at the electroweak scale are introduced, an analysis of long lived sterile neutrinos, and an analysis of short lived sterile neutrinos. Both analyses include background studies and sensitivity estimates for the FCC-ee detector. The study of long lived sterile neutrinos is based on a search for detectable displaced vertices with 1012 Z decays, obtaining a search reach on the mixing angle |θ| 2 as small as 10−11. The study of short lived sterile neutrinos is a Monte Carlo study with a cut-based analysi...

  2. Applying the sterile insect technique to the control of insect pests

    International Nuclear Information System (INIS)

    LaChance, L.E.; Klassen, W.

    1991-01-01

    The sterile insect technique (SIT) is basically a novel twentieth century approach to insect birth control. It is species specific and exploits the mate seeking behaviour of the insect. The basic principle is simple. Insects are mass reared in 'factories' and sexually sterilized by gamma rays from a 60 Co source. The sterile insects are then released in a controlled fashion into nature. Matings between the sterile insects released and native insects produced no progeny. If enough of these matings take place, reproduction of the pest population decreases. With continued release, the pest population can be controlled and in some cases eradicated. In the light of the many important applications of the SIT worldwide and the great potential that SIT concepts hold for insect and pest control in developing countries, two special benefits should be stressed. Of greatest significance is the fact that the SIT permits suppression and eradication of insect pests in an environmentally harmless manner. It combines nuclear techniques with genetic approaches and, in effect, replaces intensive use of chemicals in pest control. Although chemicals are used sparingly at the outset in some SIT programmes to reduce the size of the pest population before releases of sterilized insects are started, the total amount of chemicals used in an SIT programme is a mere fraction of what would be used without the SIT. It is also of great importance that the SIT is not designed strictly for the eradication of pest species but can readily be used in the suppression of insect populations. In fact, the SIT is ideally suited for use in conjunction with other agricultural pest control practices such as the use of parasites and predators, attractants and cultural controls (e.g. ploughing under or destruction of crop residues) in integrated pest management programmes to achieve control at the lowest possible price and with a minimum of chemical contamination of the environment

  3. Applying the sterile insect technique to the control of insect pests

    Energy Technology Data Exchange (ETDEWEB)

    LaChance, L E; Klassen, W [Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture, Vienna (Austria)

    1991-09-01

    The sterile insect technique (SIT) is basically a novel twentieth century approach to insect birth control. It is species specific and exploits the mate seeking behaviour of the insect. The basic principle is simple. Insects are mass reared in 'factories' and sexually sterilized by gamma rays from a {sup 60}Co source. The sterile insects are then released in a controlled fashion into nature. Matings between the sterile insects released and native insects produced no progeny. If enough of these matings take place, reproduction of the pest population decreases. With continued release, the pest population can be controlled and in some cases eradicated. In the light of the many important applications of the SIT worldwide and the great potential that SIT concepts hold for insect and pest control in developing countries, two special benefits should be stressed. Of greatest significance is the fact that the SIT permits suppression and eradication of insect pests in an environmentally harmless manner. It combines nuclear techniques with genetic approaches and, in effect, replaces intensive use of chemicals in pest control. Although chemicals are used sparingly at the outset in some SIT programmes to reduce the size of the pest population before releases of sterilized insects are started, the total amount of chemicals used in an SIT programme is a mere fraction of what would be used without the SIT. It is also of great importance that the SIT is not designed strictly for the eradication of pest species but can readily be used in the suppression of insect populations. In fact, the SIT is ideally suited for use in conjunction with other agricultural pest control practices such as the use of parasites and predators, attractants and cultural controls (e.g. ploughing under or destruction of crop residues) in integrated pest management programmes to achieve control at the lowest possible price and with a minimum of chemical contamination of the environment.

  4. Dark radiation sterile neutrino candidates after Planck data

    Energy Technology Data Exchange (ETDEWEB)

    Valentino, Eleonora Di; Melchiorri, Alessandro [Physics Department and INFN, Università di Roma ' ' La Sapienza' ' , Ple Aldo Moro 2, 00185, Rome (Italy); Mena, Olga, E-mail: eleonora.divalentino@roma1.infn.it, E-mail: alessandro.melchiorri@roma1.infn.it, E-mail: omena@ific.uv.es [IFIC, Universidad de Valencia-CSIC, 46071, Valencia (Spain)

    2013-11-01

    Recent Cosmic Microwave Background (CMB) results from the Planck satellite, combined with previous CMB data and Hubble constant measurements from the Hubble Space Telescope, provide a constraint on the effective number of relativistic degrees of freedom 3.62{sup +0.50}{sub −0.48} at 95% CL. New Planck data provide a unique opportunity to place limits on models containing relativistic species at the decoupling epoch. We present here the bounds on sterile neutrino models combining Planck data with galaxy clustering information. Assuming N{sub eff} active plus sterile massive neutrino species, in the case of a Planck+WP+HighL+HST analysis we find m{sub ν,} {sub sterile}{sup eff} < 0.36 eV and 3.14 < N{sub eff} < 4.15 at 95% CL, while using Planck+WP+HighL data in combination with the full shape of the galaxy power spectrum from the Baryon Oscillation Spectroscopic Survey BOSS Data Relase 9 measurements, we find that 3.30 < N{sub eff} < 4.43 and m{sub ν,} {sub sterile}{sup eff} < 0.33 eV both at 95% CL with the three active neutrinos having the minimum mass allowed in the normal hierarchy scheme, i.e. ∑m{sub ν} ∼ 0.06 eV. These values compromise the viability of the (3+2) massive sterile neutrino models for the parameter region indicated by global fits of neutrino oscillation data. Within the (3+1) massive sterile neutrino scenario, we find m{sub ν,} {sub sterile}{sup eff} < 0.34 eV at 95% CL. While the existence of one extra sterile massive neutrino state is compatible with current oscillation data, the values for the sterile neutrino mass preferred by oscillation analyses are significantly higher than the current cosmological bound. We review as well the bounds on extended dark sectors with additional light species based on the latest Planck CMB observations.

  5. Use of geographic information systems and spatial analysis in area-wide integrated pest management programmes that integrate the sterile insect technique

    International Nuclear Information System (INIS)

    Cox, J.St.H.; Vreysen, M.J.B.

    2005-01-01

    The advantages that geographic information systems (GIS) and associated technologies can offer, in terms of the design and implementation of area-wide programmes of insect and/or disease suppression, are becoming increasingly recognised, even if the realization of this potential has not been fully exploited and for some area-wide programmes adoption appears to be progressing slowly. This chapter provides a basic introduction to the science of GIS, Global Positioning System (GPS), and satellite remote sensing (RS), and reviews the principal ways in which these technologies can be used to assist various stages of development of the sterile insect technique (SIT) as part of area-wide integrated pest management (AW-IPM) programmes - from the selection of project sites, and feasibility assessments and planning of pre-intervention surveys, to the monitoring and analysis of insect suppression programmes, and the release of sterile insects. Potential barriers to the successful deployment of GIS tools are also discussed. (author)

  6. Radiation sterilization: an industrial process

    International Nuclear Information System (INIS)

    Ley, F.J.

    1975-01-01

    A new dimension has been added to the use of radiation in the medical field with the introduction of radiation as a sterilizing agent. Its use in diagnosis through radioactive tracers or X-rays and in therapy administered with the most sophisticated of electrical machines or radioisotope units, is familiar in the hospital world, being well established therein. In contrast, the application of radiation sterilization is in industry where the installation of large radiation sources is already commonplace in many countries. The beginnings in the early 1950's centered on the Van de Graaff machine and linear accelerators and the pioneering efforts of Ethicon Inc. here in the United States must be recognized. However, although sterilization with electron beams is still current practice in a number of plants, the use of gamma rays from cobalt-60 is preferred. The first steps in this direction were taken by the U.K.A.E.A. which, in common with similar organizations elsewhere, was attempting to exploit the tremendous potential for cobalt-60 production arising through the rapid construction of nuclear reactors. The first full-scale commercial gamma plant was commissioned in the U.K. in 1960. It reached a loading of 500,000 curies before its demolition after twelve years of operation. The process gained rapid acceptance within industry and approval by health authorities because it provided a ''cold'' sterilization method combining the property of lethal effect with penetration. Its immediate impact occurred in the introduction of disposable products making it possible, for example, to use heat-labile plastics and new packaging materials and package designs. Certainly, the technique has proved complementary to sterilization methods based on heat and to the use of chemical agents, in particular ethylene oxide gas

  7. Effects of sterile neutrino and extra-dimension on big bang nucleosynthesis

    Science.gov (United States)

    Jang, Dukjae; Kusakabe, Motohiko; Cheoun, Myung-Ki

    2018-04-01

    We study effects of the sterile neutrino in the five-dimensional universe on the big bang nucleosynthesis (BBN). Since the five-dimensional universe model leads to an additional term in the Friedmann equation and the energy density of the sterile neutrino increases the total energy density, this model can affect the primordial abundance via changing the cosmic expansion rate. The energy density of the sterile neutrino can be determined by a rate equation for production of the sterile neutrino. We show that not only the mixing angle and the mass of the sterile neutrino, but also a resonant effect in the oscillation between sterile and active neutrinos is important to determine a relic abundance of the sterile neutrino. In this study, we also investigate how the sterile neutrino in extra-dimensional model can affect the BBN, and constrain the parameters related to the above properties of the sterile neutrino by using the observational primordial abundances of light elements.

  8. Design and implementation of strategies for the assurance of quality for sterility testing in the Quality Control Section of the Chilean Nuclear Energy Commission

    International Nuclear Information System (INIS)

    Olave Carreno, Evelyn Karina

    2015-01-01

    The Department of Production and Service of the Chilean Nuclear Energy Commission (CCHEN), is an organization dedicated to the production and quality control of radioisotopes and radiopharmaceuticals. To be considered pharmaceutical specialties, the department has implemented a quality assurance system to guarantee compliance with the required standards during manufacturing processes, quality control and distribution. Such products are administered, mostly by via parental; that is why it is extremely important that as an injectable solution is sterile non-pyrogenic. Therefore, the Head of Quality Control Section emphasized the importance of validating sterility testing for these products. In the first instance we proceeded to update the related documentation, as this is one of the essential pillars of a good system of quality assurance, then continuing with the verification of compliance with the physical conditions of the place where the infertility tests are performed (classification of areas from a microbiological point of view). During this process, the proper training of personnel involved in performing environmental testing and sterility testing was performed. Finally, we proceeded to validate the sterility test by the method of direct inoculation three radiopharmaceuticals; also implemented sterility testing by membrane filtration method described in the USP. It was possible to validate the methods of direct inoculation and membrane filtration based on the validation protocol guidelines generated and previously approved by the Chief; demonstrating that in both cases the detection of reference strains of inocula is achieved under 100 cfu (Staphylococcus aureus, Bacillus spizizenii, Pseudomonas aeruginosa, Clostridium sporogenes, Candida albicans, Aspergillus brasiliensis), without interference of two of the products tested and interference of a product by direct inoculation method which was resolved. Based on these results, the documented evidence that

  9. Comparative transcript profiling of fertile and sterile flower buds from multiple-allele-inherited male sterility in Chinese cabbage (Brassica campestris L. ssp. pekinensis).

    Science.gov (United States)

    Zhou, Xue; Liu, Zhiyong; Ji, Ruiqin; Feng, Hui

    2017-10-01

    We studied the underlying causes of multiple-allele-inherited male sterility in Chinese cabbage (Brassica campestris L. ssp. pekinensis) by identifying differentially expressed genes (DEGs) related to pollen sterility between fertile and sterile flower buds. In this work, we verified the stages of sterility microscopically and then performed transcriptome analysis of mRNA isolated from fertile and sterile buds using Illumina HiSeq 2000 platform sequencing. Approximately 80% of ~229 million high-quality paired-end reads were uniquely mapped to the reference genome. In sterile buds, 699 genes were significantly up-regulated and 4096 genes were down-regulated. Among the DEGs, 28 pollen cell wall-related genes, 54 transcription factor genes, 45 phytohormone-related genes, 20 anther and pollen-related genes, 212 specifically expressed transcripts, and 417 DEGs located on linkage group A07 were identified. Six transcription factor genes BrAMS, BrMS1, BrbHLH089, BrbHLH091, BrAtMYB103, and BrANAC025 were identified as putative sterility-related genes. The weak auxin signal that is regulated by BrABP1 may be one of the key factors causing pollen sterility observed here. Moreover, several significantly enriched GO terms such as "cell wall organization or biogenesis" (GO:0071554), "intrinsic to membrane" (GO:0031224), "integral to membrane" (GO:0016021), "hydrolase activity, acting on ester bonds" (GO:0016788), and one significantly enriched pathway "starch and sucrose metabolism" (ath00500) were identified in this work. qRT-PCR, PCR, and in situ hybridization experiments validated our RNA-seq transcriptome analysis as accurate and reliable. This study will lay the foundation for elucidating the molecular mechanism(s) that underly sterility and provide valuable information for studying multiple-allele-inherited male sterility in the Chinese cabbage line 'AB01'.

  10. Cytoplasmic male sterility (CMS) in hybrid breeding in field crops.

    Science.gov (United States)

    Bohra, Abhishek; Jha, Uday C; Adhimoolam, Premkumar; Bisht, Deepak; Singh, Narendra P

    2016-05-01

    A comprehensive understanding of CMS/Rf system enabled by modern omics tools and technologies considerably improves our ability to harness hybrid technology for enhancing the productivity of field crops. Harnessing hybrid vigor or heterosis is a promising approach to tackle the current challenge of sustaining enhanced yield gains of field crops. In the context, cytoplasmic male sterility (CMS) owing to its heritable nature to manifest non-functional male gametophyte remains a cost-effective system to promote efficient hybrid seed production. The phenomenon of CMS stems from a complex interplay between maternally-inherited (mitochondrion) and bi-parental (nucleus) genomic elements. In recent years, attempts aimed to comprehend the sterility-inducing factors (orfs) and corresponding fertility determinants (Rf) in plants have greatly increased our access to candidate genomic segments and the cloned genes. To this end, novel insights obtained by applying state-of-the-art omics platforms have substantially enriched our understanding of cytoplasmic-nuclear communication. Concomitantly, molecular tools including DNA markers have been implicated in crop hybrid breeding in order to greatly expedite the progress. Here, we review the status of diverse sterility-inducing cytoplasms and associated Rf factors reported across different field crops along with exploring opportunities for integrating modern omics tools with CMS-based hybrid breeding.

  11. Impact of ethylene oxide gas sterilization of duodenoscopes after a carbapenem-resistant Enterobacteriaceae outbreak.

    Science.gov (United States)

    Naryzhny, Igor; Silas, Dean; Chi, Kenneth

    2016-08-01

    Carbapenem-resistant Enterobacteriaceae (CRE) outbreaks have been implicated at several medical institutions involving gastroenterology laboratories and, specifically, duodenoscopes. Currently, there are no specific guidelines to eradicate or prevent the outbreak of this bacteria. We describe ethylene oxide (ETO) gas sterilizations of duodenoscopes to address this issue. A complete investigation of the gastroenterology laboratory and an evaluation by the Centers for Disease Control and Prevention concluded that no lapses were found in the reprocessing of the equipment. With no deficiencies to address, we began a novel cleaning process using surgical ETO gas sterilizers in addition to standard endoscope reprocessing recommendations and guidelines, all while trying to eradicate the CRE contamination and prevent future recurrences. We also instituted a surveillance system for recurrence of CRE contamination via monthly cultures of the duodenoscopes. Between October 2013 and April 2014, 589 ERCPs were performed with 645 ETO gas sterilizations of 6 duodenoscopes. Given the extra 16 hours needed to sterilize the duodenoscopes, our institution incurred costs resulting from purchasing additional equipment and surveillance cultures. Four duodenoscopes sustained damage during this period; however, this could not be directly attributed to the sterilization process. Furthermore, after an 18-month success period we encountered a positive CRE culture after sterilization, albeit of a different strain than originally detected during the outbreak. The duodenoscope underwent additional ETO gas sterilization, with a negative repeated culture; all potentially exposed individuals screened negative for CRE. Proper use of high-level disinfection alone may not eliminate multidrug-resistant organisms from duodenoscopes. In this single-center study, the addition of ETO sterilization and frequent monitoring with cultures reduced duodenoscope contamination and eliminated clinical infections

  12. Sterile Neutrino Search with MINOS

    International Nuclear Information System (INIS)

    Devan, Alena V.

    2015-01-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm 2 . An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, Δm s 2 ~ 1 eV 2 . The results of the 2013 sterile neutrino search are presented here.

  13. Consultants Group Meeting on Production System Analysis and Economics for Tsetse Fly Mass-Rearing and the Use of the Sterile Insect Technique in Eradication Programmes in Africa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1991-07-01

    A consultants' group met in Vienna from 23 September - 3 October 1991 to explore 'Production System Analysis and Economics for Tsetse Fly Mass-rearing and the Use of the Sterile Insect Technique in Eradication Programmes in Africa'. This report is based on their observations during working visits to the Entomology Unit of the IAEA Agricultural Laboratory at Seibersdorf, and on information supplied by the tsetse team and staff of the Joint FAO/IAEA Division's Insect and Pest Control Section. The consultants conducted a technical, operational and financial review of present rearing methods, equipment, philosophies and production capacities, taking into account one of the recommendations made at the 6th Session of the ''FAO Commission on African Animal Trypanosomiasis'' held in June 1991 in Harare, Zimbabwe. This recommendation, related to the use of the Sterile Insect Technique (SIT), states that {sup F}AO, through the Joint FAO/IAEA Division, should further investigate and improve the use of sterile insects to strengthen the efficacy of tsetse surveys and, where applicable, consider teh use of the SIT to support eradication campaigns where other techniques on their own will not achieve this objective''. In investigating the potential for improved tsetse mass-rearing and analyzing the present costs of pupa/distributable sterile fly production, the consultants noted that: 1. The Seibersdorf Tsetse Unit is conducting an effective research and development programme which strives to emulate a production facility while continuing to pursue R and D. The capacity of the present facility in Seibersdorf is practically limited to a colony size of about 150,000 breeding females. The release of sterile males in an eradication campaign of economical relevance would require a colony containing more than 500,000 female flies. Such a population can only be maintained in an organizational, operational and financially justifiable manner if the rearing technology is transferred from an

  14. Genetically conditioned male sterility

    International Nuclear Information System (INIS)

    Gottschalk, W.

    1976-01-01

    A survey is given of two different types of genetically controlled male sterility in higher plants. 'Functional' male sterility is due to the action of mutated genes causing a misdifferentiation of the growing points in different specific ways. Under the influence of the genes of this group either the stamens or the archespore tissues are not differentiated. In other mutants functionable male germ cells are produced but cannot be used for fertilizing the egg cells because the anthers remain closed or anthers and stigma become spatially separated from each other. Other genes of the group are responsible for the transformation of stamens into carpels, i.e. for a change of the hermaphrodite flower into a unisexually female one. A second type of male sterility is due to the action of ms genes influencing the course of micro-sporogenesis directly. They cause the breakdown of this process in a specific meiotic stage characteristic for each gene of the group. This breakdown is introduced by the degeneration of PMCs, microspores, or pollen grains preventing the production of male germ cells. The female sex organs remain uninfluenced. (author)

  15. Sterilization by oxygen plasma

    Energy Technology Data Exchange (ETDEWEB)

    Moreira, Adir Jose; Mansano, Ronaldo Domingues; Andreoli Pinto, Terezinha de Jesus; Ruas, Ronaldo; Silva Zambon, Luis da; Silva, Monica Valero da; Verdonck, Patrick Bernard

    2004-07-31

    The use of polymeric medical devices has stimulated the development of new sterilization methods. The traditional techniques rely on ethylene oxide, but there are many questions concerning the carcinogenic properties of the ethylene oxide residues adsorbed on the materials after processing. Another common technique is the gamma irradiation process, but it is costly, its safe operation requires an isolated site and it also affects the bulk properties of the polymers. The use of a gas plasma is an elegant alternative sterilization technique. The plasma promotes an efficient inactivation of the micro-organisms, minimises the damage to the materials and presents very little danger for personnel and the environment. Pure oxygen reactive ion etching type of plasmas were applied to inactivate a biologic indicator, the Bacillus stearothermophilus, to confirm the efficiency of this process. The sterilization processes took a short time, in a few minutes the mortality was complete. In situ analysis of the micro-organisms' inactivating time was possible using emission spectrophotometry. The increase in the intensity of the 777.5 nm oxygen line shows the end of the oxidation of the biologic materials. The results were also observed and corroborated by scanning electron microscopy.

  16. Impediment to Symbiosis Establishment between Giant Clams and Symbiodinium Algae Due to Sterilization of Seawater

    Science.gov (United States)

    Kurihara, Takeo; Yamada, Hideaki; Inoue, Ken; Iwai, Kenji; Hatta, Masayuki

    2013-01-01

    To survive the juvenile stage, giant clam juveniles need to establish a symbiotic relationship with the microalgae Symbiodinium occurring in the environment. The percentage of giant clam juveniles succeeding in symbiosis establishment (“symbiosis rate”) is often low, which is problematic for seed producers. We investigated how and why symbiosis rates vary, depending on whether giant clam seeds are continuously reared in UV treated or non treated seawater. Results repeatedly demonstrated that symbiosis rates were lower for UV treated seawater than for non treated seawater. Symbiosis rates were also lower for autoclaved seawater and 0.2-µm filtered seawater than for non treated seawater. The decreased symbiosis rates in various sterilized seawater suggest the possibility that some factors helping symbiosis establishment in natural seawater are weakened owing to sterilization. The possible factors include vitality of giant clam seeds, since additional experiments revealed that survival rates of seeds reared alone without Symbiodinium were lower in sterilized seawater than in non treated seawater. In conclusion, UV treatment of seawater was found to lead to decreased symbiosis rates, which is due possibly to some adverse effects common to the various sterilization techniques and relates to the vitality of the giant clam seeds. PMID:23613802

  17. Combined effects of a chemical mutagen and radiation sterilized diet in mutagenicity and reproduction studies in the same mouse

    International Nuclear Information System (INIS)

    Renner, H.W.

    1975-01-01

    The possible intensification of the mutagenic effect of cyclophosphamide (Endoxan) by the feeding of a radiation-sterilized diet (dose, 4.5 Mrad) was studied in 2000 NMRI/Han mice. In a dominant lethal test, males were pretreated with 100 mg Endoxan/kg body weight. The greatest sensitivity towards Endoxan was observed during the late-spermatid stage. No significant differences were detected between the control group (Endoxan plus non-irradiated diet) and the experimental group (Endoxan plus radiation-sterilized diet). In this test, radiation-sterilized feed showed no co-mutagenic effect when combined with Endoxan treatment. In a reproduction study of 7 months duration (continuous mating without lactation periods), the females were treated every 2 wk with 20 mg Endoxan/kg body weight. The decline in litter size with increasing number of litters (i.e. with advancing age of the females) was more pronounced after treatment with the chemical mutagen than in the untreated group. Increases in the frequency of abortions and in premature sterility resulted from Endoxan treatment. During the entire observation period, no effects from the intake of radiation-sterilized food were detected. (author)

  18. Radiation sterilization of traditional medicine drugs in Vietnam

    International Nuclear Information System (INIS)

    Hang, N.D.; Canh, T.T.; Thuy, T.T.

    1995-01-01

    With the application of Gamma Co-60 radiation sterilization in pharmaceutical industry, attention should be paid to the possibilities of sterilizing traditional medicine drugs produced in Vietnam. In this paper the opinion which traditional medicine drugs can be satisfactorily sterilized by irradiation is based on the changes of physical and chemical properties of the products and microbiological examinations. The sterilizing radiation dose were calculated and the results are the following (in Mrad) Rheumatine-2.2, Hasinh-3.3, snake extract-1.8, Samcotgiao-2.2. The changes of physical and chemical properties of the products and their toxicity after irradiation have been shown to be not over the levels of allowance. (Author)

  19. Radiation sterilization of traditional medicine drugs in Vietnam

    Energy Technology Data Exchange (ETDEWEB)

    Hang, N.D.; Canh, T.T.; Thuy, T.T. [Nuclear Research Inst., Da Lat (Viet Nam)

    1995-10-01

    With the application of Gamma Co-60 radiation sterilization in pharmaceutical industry, attention should be paid to the possibilities of sterilizing traditional medicine drugs produced in Vietnam. In this paper the opinion which traditional medicine drugs can be satisfactorily sterilized by irradiation is based on the changes of physical and chemical properties of the products and microbiological examinations. The sterilizing radiation dose were calculated and the results are the following (in Mrad) Rheumatine-2.2, Hasinh-3.3, snake extract-1.8, Samcotgiao-2.2. The changes of physical and chemical properties of the products and their toxicity after irradiation have been shown to be not over the levels of allowance. (Author).

  20. Nuclear-Cytoplasmic male-sterility in diploid dandelions

    NARCIS (Netherlands)

    van der Hulst, R.G.M.; Meirmans, P.; van Tienderen, P.H.; Van Damme, J.M.M.

    2004-01-01

    Male-sterility was found in diploid dandelions from two widely separated populations from France, and its inheritance was analysed by crossing a diploid male-sterile dandelion to diploid sexuals and triploid apomicts. Nuclear genetic variation, found in full-sib families, segregated for

  1. Nuclear-cytoplasmic male-sterility in diploid dandelions

    NARCIS (Netherlands)

    van der Hulst, R.G.M.; Meirmans, P.G.; van Tienderen, P.H.; van Damme, J.M.M.

    2004-01-01

    Male-sterility was found in diploid dandelions from two widely separated populations from France, and its inheritance was analysed by crossing a diploid male-sterile dandelion to diploid sexuals and triploid apomicts. Nuclear genetic variation, found in full-sib families, segregated for male

  2. Practical problems in radiation sterilization of medical devices made from plasticized PVC

    International Nuclear Information System (INIS)

    Beenen, J.H.

    1990-01-01

    The following three methods for sterilizing medical devices made from plasticised PVC are used in the Netherlands. 1. sterilization by steam, steam-air or superheated water. 2. sterilization by electron beam or gamma irradiation. 3. ethylene oxide sterilization. IV-bags, blood bags and other bag types for similar applications made from plasticized PVC are mostly sterilized by steam-air or super heated water, especially when filled or partly filled containers are considered. More complicated products or products with components that cannot resist steam sterilization of 121 0 C are sterilized by ethylene oxide or irradiation. These last two methods also are favoured for sterilizing empty bags where sticking of the surfaces at the sterilization temperature creates a serious handicap. Moreover, steam sterilization may cause a permanent opacity of some plastics. However, we have to add that due to developments in formulations steam sterilization of empty bags is going to be of an increasing importance. proven carcinogenity of the gas ethylene oxide, difficult deaeration and retention of the gas in plasticized PVC has increased the demand for better radiation resistant plastics as an alternative for steam sterilization. (author)

  3. What do you mean you can't sterilize it? The reusable medical device matrix.

    Science.gov (United States)

    Stephens, Anne; Assang, AnnMarie

    2010-12-01

    Health Canada recommends that hospitals should have procedures in place to ensure Reusable Medical Devices (RMD) are cleaned, disinfected and sterilized according to the manufacturer's instructions. For the purpose of this paper, reusable medical devices will be referred to as RMDs and include all instrumentation and devices that the Central Processing Department (CPD) resterilizes for use in the hospital. Patient safety in surgery begins in CPD. Manufacturer recommendations for the decontamination and sterilization of surgical instrumentation are of utmost importance to Operating Room (OR) and CPD staff. With recommendations that are unclear, nonspecific or unattainable there was a need to define what it means institutionally to meet standards and provide safe patient care while continuing to support the advancement of surgical technology. The purpose of this paper is to describe the challenges faced by one multisite organization (The University Health Network) in managing the sterilization of surgical instrumentation. The development of The Guidance Matrix by the network's inter-professional Reusable Medical Device (RMD) Committee, will be discussed along with information about the elements of this tool and an illustration of how it is used. The key benefits of The Guidance Matrix, including how its use has facilitated transparent decision-making, communication and collaboration regarding sterilization issues across the sites, will be described. Sterilization processes in Central Processing Departments (CPD) include chemical indicators, dated load indicators, and tamperproof locks and filters. The lack of an indicator of sterilization can be a frustrating experience for an OR Nurse. But do we really understand the critical importance of all these indicators? The foundation of sterilizing reusable medical devices (RMDs) begins with proper processes, standards and subsequent scientific validation from the vendors. According to AORN, patient safety is vital and it

  4. Induced mutant for male sterility in niger

    International Nuclear Information System (INIS)

    Sujatha, M.

    2001-01-01

    Full text: Niger (Guizotia abyssinica Cass.), an important oilseed crop of the family Compositae is highly cross-pollinated due to the twin mechanisms of protandry and incompatibility. Studies revealed the functional nature of protandry and the breakdown of incompatibility with alteration in temperature. It has very small flowers (disc florets) arranged in a capitulum that open on 3-4 consecutive days which pose problems in emasculation for cross-breeding. To induce mutations, seeds of variety 'IGP-76' were irradiated with γ-rays 200 to 1000 Gy. All seeds of M 1 plants were sown separately in individual plant-to progeny rows. The results of screening of M 2 segregating material indicated that γ-ray treatment was effective in induction of male sterility. Frequency of visible mutations were higher in sibbed progeny as compared to open pollinated population and male sterile plants were observed only in sibbed population (1000 Gy). Male sterile plants could easily be identified at the flowering stage by their altered floral morphology (disc florets transformed into ligulate ray florets) and complete absence or presence of a rudimentary anther column. Seeds were collected following sib-mating with the fertile counterparts. Progeny segregated in a ration of 3 normal : 1 male sterile. Further work on the mechanism of sterility, maintenance and linkage relationships with associated characters is under progress. This is the first report of induction of male sterility in niger through the use of physical mutagens. The availability of this mutant will be of great value for exploitation of heterosis on commercial basis. (author)

  5. Evaluation of steam sterilization conditions for [{sup 18}F]fludeoxyglucose

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Priscilla F.; Nascimento, Leonardo T.; Valente, Eduardo S.; Silva, Juliana B.; Silveira, Marina B.; Ferreira, Soraya Z., E-mail: somafe@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Unidade de Pesquisa e Producao de Radiofarmacos

    2011-07-01

    [{sup 18}F]Flu deoxyglucose ({sup 18}FDG) is the most commonly used radiopharmaceutical for positron emission tomography. Sterile filtration of the final product into sterile vials using 0.22 {mu}m filter membrane is usually adopted for {sup 18}FDG. However, Good Manufacturing Practice (GMP) guidelines recommend heat sterilization as the method of choice to ensure sterility of pharmaceutical preparations. The aim of this study was to essay different steam sterilization conditions in order to choose the best one for {sup 18}FDG. Three different sterilization conditions were essayed. The first one at 121 deg C for 15 minutes, the second one at 135 deg C for 3.5 minutes and the third one at 133 deg C for 2 minutes. {sup 18}FDG pH-formulation was kept around 6.0. At the end of autoclave cycles, {sup 18}FDG sterility was evaluated by direct inoculation of {sup 18}FDG in culture media and radiochemical purity was determined by TLC and HPLC. Results demonstrated that all essayed conditions were able to ensure {sup 18}FDG sterility, but caused a decrease in radiochemical purity of {sup 18}FDG. Autoclave cycle at 133 deg C for 2 minutes was the best essayed condition for {sup 18}FDG terminal sterilization, once it provided the greater radiochemical purity value and took less time. {sup 18}FDG was able to meet specifications after autoclave cycles, what supports the application of steam sterilization in routine {sup 18}FDG production, in compliance with GMP. (author)

  6. Protozoa and their bacterial prey colonize sterile soil fast

    DEFF Research Database (Denmark)

    Altenburger, Andreas; Ekelund, Flemming; Jacobsen, Carsten Suhr

    2010-01-01

    We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them to the at......We know little about the ability of protozoa to colonize soils, including their successional patterns. To elucidate this issue, we investigated in which order different protozoan morpho-types colonize sterile soil. We used sterilized soils with different carbon content, and exposed them...

  7. Hybrid male sterility and genome-wide misexpression of male reproductive proteases.

    Science.gov (United States)

    Gomes, Suzanne; Civetta, Alberto

    2015-07-06

    Hybrid male sterility is a common barrier to gene flow between species. Previous studies have posited a link between misregulation of spermatogenesis genes in interspecies hybrids and sterility. However, in the absence of fully fertile control hybrids, it is impossible to differentiate between misregulation associated with sterility vs. fast male gene regulatory evolution. Here, we differentiate between these two possibilities using a D. pseudoobscura species pair that experiences unidirectional hybrid sterility. We identify genes uniquely misexpressed in sterile hybrid male reproductive tracts via RNA-seq. The sterile male hybrids had more misregulated and more over or under expressed genes relative to parental species than the fertile male hybrids. Proteases were the only gene ontology class overrepresented among uniquely misexpressed genes, with four located within a previously identified hybrid male sterility locus. This result highlights the potential role of a previously unexplored class of genes in interspecific hybrid male sterility and speciation.

  8. PRINCIPLES OF HEAT STERILIZATION IN DENTAL PRACTICE

    African Journals Online (AJOL)

    PRINCIPLES OF HEAT STERILIZATION. IN DENTAL PRACTICE. W.H. van Palenstein Helderman. Department of Community and Preventive Dentistry,. Faculty of Dentistry, Muhimbili University College of Health Sciences,. Dar es Salaam, Tanzania. Introduction. Sterilization is defined as the destruction of all forms of life ...

  9. The effects of sterilization on the tensile strength of orthodontic wires.

    Science.gov (United States)

    Staggers, J A; Margeson, D

    1993-01-01

    The purpose of this study was to evaluate the effect of sterilization on the tensile strength of 0.016" beta-titanium, nickel titanium and stainless steel wires. Three common methods of sterilization--autoclaving, dry heat and ethylene oxide--were evaluated in three test trials involving zero, one and five sterilization cycles. For each of the test trials, five pieces each of 0.016" TMA, 0.016" Sentalloy and 0.016" Tru-chrome stainless steel wires were sterilized using a standard autoclave. Five other pieces of each of the same wires were sterilized in a dryclave, while an additional five pieces of each of the three wire types were sterilized using ethylene oxide. The ultimate tensile strengths of the wires were then determined using an Instron Universal Testing Machine. The data were compared for statistical differences using analysis of variance. The results showed that dry heat sterilization significantly increased the tensile strength of TMA wires after one cycle, but not after five cycles. Autoclaving and ethylene oxide sterilization did not significantly alter the tensile strength of TMA wires. Dry heat and autoclave sterilization also significantly increased the tensile strength of Sentalloy wires, but the mean strength after five sterilization cycles was not significantly different than after one cycle. Ethylene oxide sterilization of Sentalloy wires did not significantly alter the tensile strengths of that wire. There were no significant differences in the tensile strengths of the stainless steel wires following zero, one or five cycles for any of the sterilization methods.

  10. Gamma ray induced male sterility mutant in lentil

    International Nuclear Information System (INIS)

    Srivastava, A.; Yadav, A.K.

    2001-01-01

    Full text: Male sterility refers to the failure of pollen grains to bring about effective fertilization, either due to structural default or physiological disfunctioning and has special significance in hybridization programmes. Male steriles have been produced in a number of crop plants like red gram, pigeon pea, mung bean, khesari and lentil. A completely male sterile mutant was isolated in Lens culinaris Medik, after seed treatment with 100 Gy dose of gamma rays. The male sterile mutant showed 100% pollen sterility but was morphologically more vigorous than the parent plants. It showed more branches and its leaves were bigger, more oblong and dark green. The number of flowers borne by the mutant was significantly higher than any other plant of the treatment. The size of the flowers was also increased but the anthers were smaller in size. Pollen grains were few in number, round in shape but empty and did not take up any stain, indicating that normal microsporogenesis had not taken place. This male sterile mutant was used as the female parent and pollinated with pollen of a parent. Four pods with one seed in each were formed indicating that the mutant was female fertile. The seeds were smaller than those of the parent variety and also dark coloured. The mutant showed increased vigour and flower number as compared to parental plants. Lentil is an important pulse crop and induction of variability in its germplasm is necessary for its improvement. Male steriles can be used conveniently in lentil hybridization programmes. (author)

  11. APSIC guidelines for disinfection and sterilization of instruments in health care facilities

    Directory of Open Access Journals (Sweden)

    Moi Lin Ling

    2018-02-01

    Full Text Available Abstract Background The Asia Pacific Society of Infection Control launched its revised Guidelines for Disinfection and Sterilization of Instruments in Health Care Facilities in February 2017. This document describes the guidelines and recommendations for the reprocessing of instruments in healthcare setting. It aims to highlight practical recommendations in a concise format designed to assist healthcare facilities at Asia Pacific region in achieving high standards in sterilization and disinfection. Method The guidelines were revised by an appointed workgroup comprising experts in the Asia Pacific region, following reviews of previously published guidelines and recommendations relevant to each section. Results It recommends the centralization of reprocessing, training of all staff with annual competency assessment, verification of cleaning, continual monitoring of reprocessing procedures to ensure their quality and a corporate strategy for dealing with single-use and single-patient use medical equipment/devices. Detailed recommendations are also given with respect to reprocessing of endoscopes. Close working with the Infection Prevention & Control department is also recommended where decisions related to reprocessing medical equipment/devices are to be made. Conclusions Sterilization facilities should aim for excellence in practices as this is part of patient safety. The guidelines that come with a checklist help service providers identify gaps for improvement to reach this goal.

  12. Genetics and evolution of hybrid male sterility in house mice.

    Science.gov (United States)

    White, Michael A; Stubbings, Maria; Dumont, Beth L; Payseur, Bret A

    2012-07-01

    Comparative genetic mapping provides insights into the evolution of the reproductive barriers that separate closely related species. This approach has been used to document the accumulation of reproductive incompatibilities over time, but has only been applied to a few taxa. House mice offer a powerful system to reconstruct the evolution of reproductive isolation between multiple subspecies pairs. However, studies of the primary reproductive barrier in house mice-hybrid male sterility-have been restricted to a single subspecies pair: Mus musculus musculus and Mus musculus domesticus. To provide a more complete characterization of reproductive isolation in house mice, we conducted an F(2) intercross between wild-derived inbred strains from Mus musculus castaneus and M. m. domesticus. We identified autosomal and X-linked QTL associated with a range of hybrid male sterility phenotypes, including testis weight, sperm density, and sperm morphology. The pseudoautosomal region (PAR) was strongly associated with hybrid sterility phenotypes when heterozygous. We compared QTL found in this cross with QTL identified in a previous F(2) intercross between M. m. musculus and M. m. domesticus and found three shared autosomal QTL. Most QTL were not shared, demonstrating that the genetic basis of hybrid male sterility largely differs between these closely related subspecies pairs. These results lay the groundwork for identifying genes responsible for the early stages of speciation in house mice.

  13. Impact of moth suppression/eradication programmes using the sterile insect technique or inherited sterility

    International Nuclear Information System (INIS)

    Bloem, K.A.; Bloem, S.; Carpenter, J.E.

    2005-01-01

    Numerous lepidopteran species have been investigated as candidates for control using the sterile insect technique (SIT) or inherited sterility (IS). However to date only two programmes are operational - the pink bollworm containment programme in the San Joaquin Valley, California, USA, and the codling moth suppression programme in British Columbia, Canada. Both of these programmes have been highly successful in controlling the pest populations, reducing insecticide use, and improving interactions between growers and the general public. However, other benefits, including the positive economic impacts of these programmes, have not been fully quantified. Methods to reduce the cost of lepidopteran programmes might include combining the SIT/IS with other pest control tactics such as mating disruption or the release of natural enemies, the development of genetic sexing strains, or the application of molecular technologies to develop genetic markers and genetic sterility. In future the greatest potential for impact of lepidopteran SIT/IS programmes may be in combating key invasive threats such as the eradication of an outbreak of the painted apple moth in New Zealand. (author)

  14. Development of the microbiological control aspects of radiation sterilization of medical supplies. Part of a coordinated programme on radiation sterilization of medical and biological products

    International Nuclear Information System (INIS)

    Horakova, V.

    1978-06-01

    The variability and extent of microbial contamination of such medical supplies as hydrophilic gauze swabs and dermo-epidermal grafts were investigated. Gross bacterial contamination was observed in the swabs, with a relative absence of water. It was concluded that medical disposable products under dried aerobic conditions can be sterilized by a minimum dose of 25 kJ/kg/2.5 Mrad if the mean value of pre-sterilization bacterial counts does not exceed 100. Products contaminated by 10,000 or more bacteria prior to sterilization must be considered ''decontaminated'' after irradiation but as rather than ''sterile'', as accepted pharmaceutically. The author recommends that the efficacy of the sterilization dose used be evaluated, assuming the decrease in contaminated items to follow the exponential law, with constants estimated as n=1.98 and k=0.44, and that the sterilization process to be controlled dosimetrically. In general, sub-process doses should be used before actual sterilization by ionizing radiation, in order to estimate the constants characterizing the decrease in contamination under given conditions. In skin grafts a dose of 25 kJ/kg was found to give a high guarantee of sterility. A minimum sterilizing dose of 20 kJ/kg was recommended, provided the mean value of microorganisms on 1 cm 2 of the disinfected and freeze-dried skin grafts from human cadavres was 100, without exceeding an upper limit of 130

  15. [Hysteroscopic tubal sterilization with Essure® devices: a retrospective descriptive study and evaluation of hypnosis].

    Science.gov (United States)

    Gauchotte, E; Masias, C; Bogusz, N; Koebele, A

    2011-06-01

    The Essure(®) system is a hysteroscopic sterilization method. The aim of our study is to retrospectively evaluate the sterilization procedure with Essure(®) devices, with and without anesthesia, and in particular with hypnosis. The descriptive study includes all tubal sterilization with Essure(®) performed during the year 2009 at the Maternité régionale de Nancy. Hypnosis efficiency is retrospectively evaluated with Verbal Numeric Rating Scale (VNRS) for peroperative pain, and analgesic medication use for postoperative pain. Ninety-four sterilizations are performed, 85% (85/94) of them without anesthesia. The mean VNRS is 3.0. The mean operative time is 8.7 minutes, positively correlated with the VNRS (P=0.0005). The rate of successful insertion is 94%. At 3 months, 91% of the implants have a correct location. Inadequate locations are more frequent when anesthesia have been performed (37% vs 4%, P=0.016). There is no significant difference between groups with and without hypnosis for the VNRS, the failure rate and the use of analgesic medication. Tubal sterilization with the Essure(®) system is a quick and efficient method. Our study does not demonstrate efficiency of hypnosis in pain control. This remains to be explored with a prospective study, including others parameters, such as anxiety. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  16. Pretreatment of vinasse from the sugar refinery industry under non-sterile conditions by Trametes versicolor in a fluidized bed bioreactor and its effect when coupled to an UASB reactor.

    Science.gov (United States)

    España-Gamboa, Elda; Vicent, Teresa; Font, Xavier; Dominguez-Maldonado, Jorge; Canto-Canché, Blondy; Alzate-Gaviria, Liliana

    2017-01-01

    During hydrous ethanol production from the sugar refinery industry in Mexico, vinasse is generated. Phenolic compounds and melanoidins contribute to its color and make degradation of the vinasse a difficult task. Although anaerobic digestion (AD) is feasible for vinasse treatment, the presence of recalcitrant compounds can be toxic or inhibitory for anaerobic microorganism. Therefore, this study presents new data on the coupled of the FBR (Fluidized Bed Bioreactor) to the UASB (Upflow Anaerobic Sludge Blanket) reactor under non-sterile conditions by T. versicolor . Nevertheless, for an industrial application, it is necessary to evaluate the performance in this kind of proposal system. Therefore, this study used a FBR for the removal of phenolic compounds (67%) and COD (38%) at non-sterile conditions. Continuous operation of the FBR was successfully for 26 days according to the literature. When the FBR was coupled to the UASB reactor, we obtained a better quality of effluent, furthermore methane content and yield were 74% and 0.18 m 3 CH 4 / kg COD removal respectively. This study demonstrated the possibility of using for an industrial application the coupled of the FBR to the UASB reactor under non-sterile conditions. Continuous operation of the FBR was carried out successfully for 26 days, which is the highest value found in the literature.

  17. Sterilization techniques without heating (ultraviolet ray, radiation and ozone)

    International Nuclear Information System (INIS)

    Ito, Hitoshi

    1991-01-01

    The recent demand of consumers for processed foods is characterized by the intention for health and nature, besides, the demand for low sweetness, salt reduction, no additive and freshness becomes strong. In view of the control of microorganisms in products, all these become the negative factors. Accordingly, in order to overcome them, it is urgently desired to develop new technology or to improve conventional methods. As to heating sterilization, the uniform temperature treatment to the inside of foods is difficult, and it cannot be applied to perishables. The high temperature sterilization above 120degC causes the change in nutrition composition and physical properties. Ultraviolet ray and ozone can be used for the sterilization of food surface and powder and liquid foods. Radiation treatment can be applied to packed foods and frozen foods as well as food surface. The principle and the fields of application of ultraviolet ray sterilization, radiation sterilization and ozone sterilization are reported. In the mechanism of these methods, the action to DNA and oxidation are common. (K.I.)

  18. Sterile Neutrino Search in the NOvA Far Detector

    Energy Technology Data Exchange (ETDEWEB)

    Edayath, Sijith [Cochin U.; Aurisano, Adam [Cincinnati U.; Sousa, Alexandre [Cincinnati U.; Davies, Gavin [Indiana U.; Suter, Louise [Fermilab; Yang, Shaokai [Cincinnati U.

    2017-10-03

    The majority of neutrino oscillation experiments have obtained evidence for neutrino oscillations that are compatible with the three-flavor model. Explaining anomalous results from short-baseline experiments, such as LSND and MiniBooNE, in terms of neutrino oscillations requires the existence of sterile neutrinos. The search for sterile neutrino mixing conducted in NOvA uses a long baseline of 810 km between Near Detector (ND) at Fermilab and Far Detector (FD) in Minnesota. The signal for sterile neutrino oscillations is a deficit of neutral-current neutrino interactions at the FD with respect to the ND prediction. In this document, We will present the analysis improvements that we are implementing for future NC sterile neutrino searches with NOvA. These include: improved modelling of our detector response; the inclusion of NC 2p2h interaction modelling; implementing a better energy reconstruction techniques; and including possible oscillation due to sterile neutrinos in the ND . This improvements enable us to do a simultaneous ND-FD shape fit of the NC energy spectrum covering a wider sterile mass range than previous analyses.

  19. 42 CFR 50.207 - Sterilization by hysterectomy.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Sterilization by hysterectomy. 50.207 Section 50.207 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS POLICIES OF GENERAL APPLICABILITY Sterilization of Persons in Federally Assisted Family Planning Projects § 50.207...

  20. Acute cardiovascular toxicity of sterilizers, PHMG, and PGH: severe inflammation in human cells and heart failure in zebrafish.

    Science.gov (United States)

    Kim, Jae-Yong; Kim, Hak Hyeon; Cho, Kyung-Hyun

    2013-06-01

    In 2011, dozens of children and pregnant women in Korea died by exposure to sterilizer for household humidifier, such as Oxy(®) and Cefu(®). Until now, however, it remains unknown how the sterilizer affect the human health to cause the acute deaths. To find its toxicity for organ, we investigated the putative toxicity of the sterilizer in the cardiovascular system. The sterilizers, polyhexamethylene guanidine phosphate (PHMG, Cefu(®)), and oligo-[2-(2-ethoxy)-ethoxyethyl)-guanidinium-chloride (PGH, Oxy(®)) were treated to human lipoproteins, macrophages, and dermal fibroblast cells. The PGH and PHMG at normal dosages caused severe atherogenic process in human macrophages, cytotoxic effect, and aging in human dermal cell. Zebrafish embryos, which were exposed to the sterilizer, showed early death with acute inflammation and attenuated developmental speed. All zebrafish exposed to the working concentration of PHMG (final 0.3 %) and PGH (final 10 mM) died within 70 min and displayed acute increases in serum triacylglycerol level and fatty liver induction. The dead zebrafish showed severe accumulation of fibrous collagen in the bulbous artery of the heart with elevation of reactive oxygen species. In conclusion, the sterilizers showed acute toxic effect in blood circulation system, causing by severe inflammation, atherogenesis, and aging, with embryo toxicity.

  1. [Characteristics and follow-up of sterilized women].

    Science.gov (United States)

    Molina, R; López, I

    1982-02-01

    In order to gain insight into the characteristics of sterilized women evaluating at the same time the effects of sterilization, 70 patients who underwent sterilization in an Obstetrics Unit were studied. The clinical records were analyzed and a questionnaire comprising general knowledge, attitudes, and conduct was applied. Women over 30 and with a parity of 4 or more predominated. There was a low frequency of abortions reported but this information is not reliable. The educational level was lower than the average for the Metropolitan Region and pointed to a more precocious initiation in sexual relationships than was found in a previous similar study. Religion proved to be no obstacle for sterilization nor was attendance to church subsequently diminished. A negative moral feeling towards the operation nearly disappeared following surgery. The fear of sexual dissatisfaction in husbands decreased following surgery and a similar effect was seen with regard to negative self-image. There were no changes in marital relations nor in their satisfaction. (author's modified)

  2. Reliability of Laparoscopic Compared With Hysteroscopic Sterilization at One Year: A Decision Analysis

    Science.gov (United States)

    Gariepy, Aileen M.; Creinin, Mitchell D.; Schwarz, Eleanor B.; Smith, Kenneth J.

    2011-01-01

    OBJECTIVE To estimate the probability of successful sterilization after hysteroscopic or laparoscopic sterilization procedure. METHODS An evidence-based clinical decision analysis using a Markov model was performed to estimate the probability of a successful sterilization procedure using laparoscopic sterilization, hysteroscopic sterilization in the operating room, and hysteroscopic sterilization in the office. Procedure and follow-up testing probabilities for the model were estimated from published sources. RESULTS In the base case analysis, the proportion of women having a successful sterilization procedure on first attempt is 99% for laparoscopic, 88% for hysteroscopic in the operating room and 87% for hysteroscopic in the office. The probability of having a successful sterilization procedure within one year is 99% with laparoscopic, 95% for hysteroscopic in the operating room, and 94% for hysteroscopic in the office. These estimates for hysteroscopic success include approximately 6% of women who attempt hysteroscopically but are ultimately sterilized laparoscopically. Approximately 5% of women who have a failed hysteroscopic attempt decline further sterilization attempts. CONCLUSIONS Women choosing laparoscopic sterilization are more likely than those choosing hysteroscopic sterilization to have a successful sterilization procedure within one year. However, the risk of failed sterilization and subsequent pregnancy must be considered when choosing a method of sterilization. PMID:21775842

  3. Sterile Neutrino Search with MINOS

    Energy Technology Data Exchange (ETDEWEB)

    Devan, Alena V. [College of William and Mary, Williamsburg, VA (United States)

    2015-08-01

    MINOS, Main Injector Neutrino Oscillation Search, is a long-baseline neutrino oscillation experiment in the NuMI muon neutrino beam at the Fermi National Accelerator Laboratory in Batavia, IL. It consists of two detectors, a near detector positioned 1 km from the source of the beam and a far detector 734 km away in Minnesota. MINOS is primarily designed to observe muon neutrino disappearance resulting from three flavor oscillations. The Standard Model of Particle Physics predicts that neutrinos oscillate between three active flavors as they propagate through space. This means that a muon-type neutrino has a certain probability to later interact as a different type of neutrino. In the standard picture, the neutrino oscillation probabilities depend only on three neutrino flavors and two mass splittings, Δm2. An anomaly was observed by the LSND and MiniBooNE experiments that suggests the existence of a fourth, sterile neutrino flavor that does not interact through any of the known Standard Model interactions. Oscillations into a theoretical sterile flavor may be observed by a deficit in neutral current interactions in the MINOS detectors. A distortion in the charged current energy spectrum might also be visible if oscillations into the sterile flavor are driven by a large mass-squared difference, ms2 ~ 1 eV2. The results of the 2013 sterile neutrino search are presented here.

  4. Inactivation of animal and human prions by hydrogen peroxide gas plasma sterilization.

    Science.gov (United States)

    Rogez-Kreuz, C; Yousfi, R; Soufflet, C; Quadrio, I; Yan, Z-X; Huyot, V; Aubenque, C; Destrez, P; Roth, K; Roberts, C; Favero, M; Clayette, P

    2009-08-01

    Prions cause various transmissible spongiform encephalopathies. They are highly resistant to the chemical and physical decontamination and sterilization procedures routinely used in healthcare facilities. The decontamination procedures recommended for the inactivation of prions are often incompatible with the materials used in medical devices. In this study, we evaluated the use of low-temperature hydrogen peroxide gas plasma sterilization systems and other instrument-processing procedures for inactivating human and animal prions. We provide new data concerning the efficacy of hydrogen peroxide against prions from in vitro or in vivo tests, focusing on the following: the efficiency of hydrogen peroxide sterilization and possible interactions with enzymatic or alkaline detergents, differences in the efficiency of this treatment against different prion strains, and the influence of contaminating lipids. We found that gaseous hydrogen peroxide decreased the infectivity of prions and/or the level of the protease-resistant form of the prion protein on different surface materials. However, the efficiency of this treatment depended strongly on the concentration of hydrogen peroxide and the delivery system used in medical devices, because these effects were more pronounced for the new generation of Sterrad technology. The Sterrad NX sterilizer is 100% efficient (0% transmission and no protease-resistant form of the prion protein signal detected on the surface of the material for the mouse-adapted bovine spongiform encephalopathy 6PB1 strain and a variant Creutzfeldt-Jakob disease strain). Thus, gaseous or vaporized hydrogen peroxide efficiently inactivates prions on the surfaces of medical devices.

  5. Fate of Staphylococcus aureus in radiation sterilized model food systems simulating dairy products

    International Nuclear Information System (INIS)

    Sulebele, G.A.; Kamat, M.Y.

    1976-01-01

    Gamma irradiation was successfully employed for the development of sterile model food systems simulating dairy products such as pedha and cottage cheese which were inoculated with enterotoxigenic S.aureus S-6 and FR1-100 either individually or in association with S.epidermids and other mixed flora comprising of gram-positive, gram-negative and lactic bacteria and stored at 4 and 35 degC for 6-8 weeks. Pedha failed to support growth of S.aureus while cottage cheese favoured profuse growth of the pathogen. S.epidermidis exhibited a synergistic effect on the growth of S.aureus in cottage cheese. Baired-Parker's medium showed very poor recovery of S.aureus which necessitated the development of a new selective medium for the enumeration of staphylococci in processed foods. (author)

  6. Is parotid saliva sterile on entry to the oral cavity?

    DEFF Research Database (Denmark)

    Schrøder, Stine A; Bardow, Allan; Eickhardt-Dalbøge, Steffen

    2017-01-01

    CONCLUSION: The present study indicates that parotid saliva is sterile on entry to the oral cavity. OBJECTIVES: The objective was to investigate if parotid saliva is sterile on entry to the oral cavity and, thus, prior to contamination by oral bacteria. METHOD: Forty healthy volunteers were...... included in sterile parotid saliva collection. Parotid saliva was collected using a sterile Lashley cup, placed over the papilla of the Stensen´s duct, as well as sterile tubes and syringes for collection. All collections were followed by collection of a positive control sample where some of the sterile...... obtained parotid saliva had been exposed to the contralateral mucosal membranes. All samples parotid saliva, as well as the positive controls, were cultivated, and 10 randomly selected parotid saliva samples underwent polymerase chain reaction (PCR) analyses. RESULTS: In 33 of 40 parotid saliva samples...

  7. Reason behind wet pack after steam sterilization and its consequences: An overview from Central Sterile Supply Department of a cancer center in eastern India.

    Science.gov (United States)

    Basu, Debabrata

    Wet pack after steam sterilization process that means there are surely obtain millions of microorganisms that can breed and multiply rapidly and objects are unsterile and can never be used for further procedure. There are many reasons behind the wet pack occurrences after autoclaving like poor quality of wrapping materials, faulty valves of rigid container, faulty loading and packaging technique, poor steam quality, sterilizer malfunction and may be design related problems in CSSD sterile storage area. Cause of wet pack after steam sterilization processes may occur severe problems because of wasted time and effort, increased work load, increased cost, potentially contaminated instruments, infection risk to the patient, poor patient outcomes and delayed or cancellation of procedures. But such wet pack scenario can be avoided by various methods by using good steam (water) quality, performing periodic maintenance of the Autoclaves, avoidance of sterilizer overloading, allowing adequate post sterilization time to cool down the materials to room temperature, using good quality wrapping materials, properly maintain temperature and humidity of sterile storage area etc. Copyright © 2016 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  8. Assessment of Non-Sterile Pharmaceutical Compounding Practices ...

    African Journals Online (AJOL)

    A descriptive cross-sectional survey was conducted to assess the practices of non-sterile pharmaceutical compounding in selected 42 community and 3 hospital pharmacies in Addis Ababa, Ethiopia from 01 April, 2016 to 15 May, 2016. The study revealed that the most commonly prescribed and compounded non-sterile ...

  9. Sodium hypochlorite sterilization of culture medium in ...

    African Journals Online (AJOL)

    With the purpose of finding an alternative to thermal sterilization, this research aimed at assessing the efficiency and ideal concentration of sodium hypochlorite for sterilization of culture media and glassware used during rooting of micropropagated Gerbera hybrida cv. Essandre. Two experiments were carried out. In the first ...

  10. Genetic expression of induced rice sterility under alien-cytoplasm

    International Nuclear Information System (INIS)

    Wang Naiyuan; Cai Zhijun; Liang Kangjing; Li Yu

    2005-01-01

    Rice restorer lines were treated with 60 Co γ-ray and 4 male sterile mutants obtained with the fertility of controlled by 4 non-allelic recessive genes, respectively. Sixty combinations were made by using male sterile plants/fertile plants as male parents, and 15 different cytoplasmic substitution lines of the same cell nucleus as female parents. The result showed that F 1 spikelets were normal and fertile, and different numbers of male sterile plants were segregated in F 2 . Complete fertility genotype was not found among interactions between induced male sterile genes and alien-cytoplasms. (authors)

  11. Development of Cytoplasmic Male Sterile IR24 and IR64 Using CW-CMS/Rf17 System.

    Science.gov (United States)

    Toriyama, Kinya; Kazama, Tomohiko

    2016-12-01

    A wild-abortive-type (WA) cytoplasmic male sterility (CMS) has been almost exclusively used for breeding three-line hybrid rice. Many indica cultivars are known to carry restorer genes for WA-CMS lines and cannot be used as maintainer lines. Especially elite indica cultivars IR24 and IR64 are known to be restorer lines for WA-CMS lines, and are used as male parents for hybrid seed production. If we develop CMS IR24 and CMS IR64, the combination of F1 pairs in hybrid rice breeding programs will be greatly broadened. For production of CMS lines and restorer lines of IR24 and IR64, we employed Chinese wild rice (CW)-type CMS/Restorer of fertility 17 (Rf17) system, in which fertility is restored by a single nuclear gene, Rf17. Successive backcrossing and marker-assisted selection of Rf17 succeeded to produce completely male sterile CMS lines and fully restored restorer lines of IR24 and IR64. CW-cytoplasm did not affect agronomic characteristics. Since IR64 is one of the most popular mega-varieties and used for breeding of many modern varieties, the CW-CMS line of IR64 will be useful for hybrid rice breeding.

  12. Estimation of populations and sterility induction in Anastrepha ludens (Diptera: Tephritidae) fruit flies

    International Nuclear Information System (INIS)

    Flores, Salvador; Montoya, Pablo; Toledo, Jorge; Liedo, Pablo; Enkerlin, Walther

    2015-01-01

    The relationship between different release densities of sterile flies and fly trap captures, expressed as flies per trap per day, in the monitoring of Anastrepha ludens (Loew) populations was evaluated in mango orchards. The induction of sterility in fertile females was evaluated using different ratios of sterile: fertile males under field cage conditions. A direct relationship between recaptured flies and densities of release sterile flies was found. However, trap efficiency, expressed as percentage of recaptured flies, decreased as the density of released flies increased. Sterility induction was positively correlated to the ratio of sterile: fertile flies. A significant difference in egg fertility among treatments was observed. The trajectory of sterility induction slowed down after a sterile: wild ratio of 30:1, which suggests that this ratio could be appropriate in an sterile insect technique program with A. ludens. Sterility induction was greater when only sterile males were released than when releasing both sterile males and females, but the differences were not significant. Our findings contribute to a better interpretation of fly captures obtained from the field trapping networks, and to an improvement in the efficiency of sterile insect technique against A. ludens fruit flies, through the implementation of more rational sterile fly release densities. (author)

  13. Modelling the effects of the sterile insect technique applied to Eldana saccharina Walker in sugarcane

    Directory of Open Access Journals (Sweden)

    L Potgieter

    2012-12-01

    Full Text Available A mathematical model is formulated for the population dynamics of an Eldana saccharina Walker infestation of sugarcane under the influence of partially sterile released insects. The model describes the population growth of and interaction between normal and sterile E.saccharina moths in a temporally variable, but spatially homogeneous environment. The model consists of a deterministic system of difference equations subject to strictly positive initial data. The primary objective of this model is to determine suitable parameters in terms of which the above population growth and interaction may be quantified and according to which E.saccharina infestation levels and the associated sugarcane damage may be measured. Although many models have been formulated in the past describing the sterile insect technique, few of these models describe the technique for Lepidopteran species with more than one life stage and where F1-sterility is relevant. In addition, none of these models consider the technique when fully sterile females and partially sterile males are being released. The model formulated is also the first to describe the technique applied specifically to E.saccharina, and to consider the economic viability of applying the technique to this species. Pertinent decision support is provided to farm managers in terms of the best timing for releases, release ratios and release frequencies.

  14. Female sterilization in India : The quality and effect of an observed sterilization camp at The Methodist Public Health Centre, Mursan, India

    OpenAIRE

    Wikborg, Pia; Svensk, Marie

    2007-01-01

    Population growth is a big challenge for India, and family planning is highly prioritized by the Government of India. Sterilization is the most common voluntary contraceptive method in India and has for many years been performed in camps. This thesis is based on our observation of a sterilization camp at the Methodist Public Health Centre in Mursan, India and available literature on the subject. We have looked closer at the effect of female sterilization as a method of contraception and t...

  15. Influence of microwave sterilization on the cutting capacity of carbide burs.

    Science.gov (United States)

    Fais, Laiza Maria Grassi; Pinelli, Lígia Antunes Pereira; Adabo, Gelson Luis; Silva, Regina Helena Barbosa Tavares da; Marcelo, Caroline Canhizares; Guaglianoni, Dalton Geraldo

    2009-01-01

    This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1), autoclave (G2), microwave irradiation (G3), glutaraldehyde (G4) or control - no sterilization (G5). The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5) following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 +/- 0.0627 g; G2 = 0.2077 +/- 0.0231 g; G3 = 0.1980 +/- 0.0326 g; G4 = 0.1203 +/- 0.0459 g; G5 = 0.2642 +/- 0.0359 g. There were statistically significant differences among the groups (p<0.05); only dry heat sterilization was similar to the control. Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.

  16. Objections to tubal sterilization: what reversibility can and cannot overcome.

    Science.gov (United States)

    Shain, R N

    1980-09-01

    In a study of 1074 women, 696 and 338 subjects would not seriously consider permanent and hypothetically reversible sterilization, respectively; they were asked to explain their feelings. The reason accounting for most objections to permanent sterilization (65%) was irreversibility and of the subjects who would not consider reversible sterilization or were unsure, 42.7% attributed their principal objection to unnecessary surgery, a factor at least currently intrinsic to the procedure and not readily overcome by education. Many of the remaining objections to both permanent and reversible sterilization may be amenable to change either through education or financial subsidies. In response to a question concerning female attractiveness subsequent to permanent sterilization, 3% of the sample felt attractiveness would decrease and 17.5% were unsure of the surgery's effect. Unsure responses were largely negative in character. This issue is important because of its relationship to intention to undergo sterilization. Upon consideration of reversible sterilization, negative and unsure responses significantly declined, even on the part of those women whose friends have had a poor experience with currently available procedures. Thus, whereas the option of reversibility cannot overcome objections to surgery, it does overcome those regarding permanency; moreover, the "temporary" character it bestows upon surgical sterilization appears to help certain individuals overcome their fears of losing their physical appeal as a result of such procedures.

  17. The efficacy of four gametocides for induction of pollen sterility in ...

    African Journals Online (AJOL)

    Habteab Ghebrehiwot

    2015-02-19

    Feb 19, 2015 ... All the CHAs significantly reduced seed yield, with E4FO, Ethrel and Promalin® at 5000 ... complex and limiting cytoplasmic male sterility systems, increasing crossing ..... (private peasant holdings, meher season). Statistical ...

  18. Contraceptive sterilization among Canadians, 1984-1995

    Directory of Open Access Journals (Sweden)

    Vijaya Krishnan

    2004-12-01

    Full Text Available Prior to early 1970s, traditional methods were the principal means of controlling the number and spacing of births. Today, an estimated 57 per cent of the world’s married women use contraceptives and half use modern methods such as medical sterilizations. Recent statistics suggest that Canada has the highest sterilization rate in the Western world. This paper presents findings of research examining sterilization trends in Canada with respect to changing patterns in the use of modern contraceptives, using data from the 1984 Canadian Fertility Survey (CFS and the 1995 General Social Survey (GSS. The main finding is that there is a decrease in the use of tubal ligation and an increase in the use of hysterectomy over the period 1984-1995. Less educated women are more likely to be in the forefront of modern methods of contraception.

  19. Hybrid male sterility is caused by mitochondrial DNA deletion.

    Science.gov (United States)

    Hayashida, Kenji; Kohno, Shigeru

    2009-07-01

    Although it is known that the hybrid male mouse is sterile just like any other animal's heterogametic sex, the reason why only the male germ cells are impaired has yet to be discovered. TdT-mediated dUTP nick end labeling assay using a confocal fluorescence microscope and DNA fragmentation assay of hybrid testis indicated destruction of the mitochondrial DNA (mtDNA) rather than the nuclear DNA. Previously we reported that maternal mtDNA inheritance is through selective sperm mtDNA elimination based on the sperm factor and two egg factors, and expression of these three factors was recognized in the hybrid testis. It was thereby assumed that mtDNA destruction caused by the expression of maternal mtDNA inheritance system in male germ cells is implicated in the hybrid male sterility of mice.

  20. Sterilization of the artificial blood circulation apparatus with ozone

    Energy Technology Data Exchange (ETDEWEB)

    Pisarevskii, A A; Korukhov, N I.U.; Brazhnikov, E M; Konstantinova, M L; Razumovskii, S D

    1982-01-01

    Presented in this paper is the sterilization method of the assisted circulation unit. The method has been approved by stand testing and then applied for sterilizing the unit Ae, yeK-5 m when experimental implanting artificial heart. According to the method, ozone in concentration of 5 x 10(-3) moles/1 and with flow rate of 0,5 1/min is passed through an internal circuit of the unit during I h and 15 min. Control wash-out samples from lines have demonstrated complete sterility of the internal circuit. The method makes the sterilization process of such units much easier and may be recommended for clinical application.

  1. Proposed Philippine radiation-sterilization plant, and a survey of market potential

    International Nuclear Information System (INIS)

    Singson, C.C.; Ibe, L.D.

    1975-01-01

    The paper deals with a study to assess the market potential of radiation sterilization in the Philippines. A market survey conducted with the technical assistance of an IAEA expert from India shows that most of the pharmaceutical industries engaged in the manufacture of medical products unanimously agree that there is an urgent need for a centralized radiation sterilization plant to meet the demands of sterilization of most of their products and packaging materials. The authorities of the government and some of the private hospitals surveyed are also very keen for the establishment of a sterilization facility since most modern medical products and devices are made of heat-sensitive thermoplastics which cannot be heat or steam sterilized. Availability of sterile products will help improve the public health standards of the population. The scope of the utilization of a radiation-sterilization facility in Diliman Quezon City is also discussed. (author)

  2. Rearing Technique, Biology and Sterilization of the Coffee Leaf Miner, Leucoptera Coffeella Guer. (Lepidoptera: Lyonetiidae)

    Energy Technology Data Exchange (ETDEWEB)

    Katiyar, K. P.; Ferrer, F. [Inter-American Institute of Agricultural Sciences of the OAS Training and Research Center, Turrialba (Costa Rica)

    1968-06-15

    For two years the authors studied the feasibility of controlling the coffee leaf miner Leucoptera coffeella Guer. by the radiation sterilization technique. During this period a technique for raising large numbers of tills insect on potted coffee plants in the laboratory was devised. The optimal range for the development of egg, larval and pupal stages of the coffee leaf miner was between 20 and 30 Degree-Sign C. The pupal stage of female insects was slightly shorter than that of the male. The laying of fertile eggs began during the first night following emergence. During an oviposition period of 16 days the average fecundity was 68 eggs. The maximum oviposition by a single female was 131 eggs over the life span while as many as 34 eggs were laid during a single day of oviposition. To investigate the best stage to induce radiation sterilization, pupal and adult insects were irradiated with {sup 60}CO gamma rays. Seven-day pupae (close to emergence) showed 88% lethality in males when given 60 krad; the survivors retained some fertility. Adult females receiving 70 krad were 100% sterile while males given 90 krad showed 0.02% fertility. Doses as high as 90 krad given to newly emerged adults did not reduce longevity. Studies are continuing to determine if sterilizing doses impair sexual vigour and mating competitiveness of the treated males. (author)

  3. Glass bead sterilizer comprehensively defeats hot air oven in orthodontic clinic

    Directory of Open Access Journals (Sweden)

    Sanjeev Vasudev Jakati

    2015-01-01

    Full Text Available Background: It is necessary to ′try in′ several bands before the correct one is selected. A possible concern with re-using such bands is the lack of cross-infection control. Aim and Objectives: To determine whether such bands could be successfully decontaminated with Glass bead sterilization so that they could be re-used without a cross-infection risk. Materials: Custom made molar bands were taken and buccal tubes,lingual sheath and lingual cleat were welded under strict aseptic conditions. Methods: Samples were divided into 2 groups i.e. A and B, based on mode for sterilization. Sterilized attachments were placed in each of 2 conical flask. The bacteria spores were inoculated into both flask under strict aseptic conditions. Bacteria Bacillus subtillis and Staphylococcus albus species were allowed to multiply in individual flasks filled with BHI broth for 24 hours. Bands from 1st group were placed in a glass bead sterilizer. For the 2 nd group i.e. hot air oven group, all bands were placed together. After sterilization bands were removed and placed in freshly sterilized 500ml conical flask containing BHI broth for 24 hours in the incubator. The following day randomly 4 attachments were selected from each group and streaked on blood agar culture plates. Results: After sterilization and on further incubation in BHI broth for 24 and 48 hrs. Respectively no growth was seen. Conclusion: 1 hr. of Hot Air Oven sterilization (excluding pre sterilization heat up time and post sterilization cooling time at 190°C is as effective as 3 min of Chair side Glass Bead sterilization.

  4. Sterilization Monitoring management of the integration of the operating room with CSSD

    Directory of Open Access Journals (Sweden)

    Shu-yan XIA

    2014-08-01

    Full Text Available Objective: Explore the Sterilization Monitoring management of the integration of the operating room with CSSD. Methods: Compare sterilization process monitoring with biological monitoring and chemical monitoring. Results: The management in Biological monitoring, chemical monitoring and sterilization process monitoring is crucial. Conclusion: Sterilization monitoring is to ensure the safe use of sterile goods so as to protect the safety of surgical patients.

  5. Temperature Effects on Free Radicals in Gamma-sterilized Beef

    Science.gov (United States)

    Pramanik, S. I.; Jahan, M. S.

    1999-11-01

    Gamma irradiation has become the method of choice for sterilizing frozen meat and their products to reduce levels of food-borne pathogens and to extend shelf life. In this report we have employed ESR technique for detection of free radicals in sterilized and non-sterilized dry beef without bone. We have also determined the heating effects on free radicals at temperatures 176^°C and 250^°C. Meat samples were dried in a food dehydrator at 60^°C and were packaged in dry N_2. They were then sterilized by γ-irradiation (2.5 MRad), ground into powder, and placed in ESR sample tubes. Non-sterilized powder samples were used as control. While all powder samples, sterilized or not, produced a broad single line in the ESR spectra with (Δ H_pp ~ 9 G) and g = 2.013, the radical concentration in the sterilized samples increased by a factor of five. Heat treatment at 176^°C produced similar radicals. But, when samples were heated 250^°C different radical species were formed which are characterized by narrow width (Δ H_pp ~ 6 G) and lower g-value (g =2.010). In contrast with previous work, where free radicals in chicken bones were reduced by heating [1], we observed an increase in concentration. Results of structural analyses of the radicals will be presented. Ref.[1]: Radiat. Phys. Chem., 49, 477-481, 1997. Work supported by Grants from the University of Memphis

  6. The genetics of hybrid male sterility between the allopatric species pair Drosophila persimilis and D. pseudoobscura bogotana: dominant sterility alleles in collinear autosomal regions.

    Science.gov (United States)

    Chang, Audrey S; Noor, Mohamed A F

    2007-05-01

    F(1) hybrid male sterility is thought to result from interactions between loci on the X chromosome and dominant-acting loci on the autosomes. While X-linked loci that contribute to hybrid male sterility have been precisely localized in many animal taxa, their dominant autosomal interactors have been more difficult to localize precisely and/or have been shown to be of relatively smaller effect. Here, we identified and mapped at least four dominant autosomal factors contributing to hybrid male sterility in the allopatric species pair Drosophila persimilis and D. pseudoobscura bogotana. Using these results, we tested predictions of reduced recombination models of speciation. Consistent with these models, three of the four QTL associated with hybrid male sterility occur in collinear (uninverted) regions of these genomes. Furthermore, these QTL do not contribute significantly to hybrid male sterility in crosses between the sympatric species D. persimilis and D. pseudoobscura pseudoobscura. The autosomal loci identified in this study provide the basis for introgression mapping and, ultimately, for molecular cloning of interacting genes that contribute to F(1) hybrid sterility.

  7. Unintended pregnancies after Essure sterilization in the Netherlands

    NARCIS (Netherlands)

    Veersema, S.; Vleugels, M.P.; Moolenaar, L.M.; Janssen, C.A.; Brölmann, H.A.M.

    2010-01-01

    Objective: To analyze the data of cases of unintended pregnancies after Essure sterilization. Design: Retrospective case series analysis. Setting: National multicenter. Patient(s): Ten cases of unintended pregnancies after Essure sterilization in the Netherlands were reported from August 2002

  8. Plasma Sterilizer with Ultrasonic Cavitation

    International Nuclear Information System (INIS)

    Krasnyj, V.V.; Klosovsky, A.V.; Panasko, T.A.; Shvets, O.M.; Semenova, O.T.; Taran, V.S.; Tereshin, V.I.

    2006-01-01

    A sterilizer consists of ozone generator based on a barrier glow discharge with the flat electrodes covered with dielectric with a high-voltage pulsed power supply of up to 250 W (1). The sterilization camera is equipped with ultrasonic source with the power of 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. Ozone concentration in the aqueous solution was 6 mg/liter with ozone concentration at the output of ozone generator 30 mg/liter. The complete inactivation of spores took 15 min

  9. Post-sterilization autonomy among young mothers in South India.

    Science.gov (United States)

    Pallikadavath, Saseendran; Rajan, Irudaya; Singh, Abhishek; Ogollah, Reuben; Page, Samantha

    2015-01-01

    This study examined the post-sterilization autonomy of women in south India in the context of early sterilization and low fertility. Quantitative data were taken from the third round of the National Family Health Survey (NFHS-3) carried out in 2005-06, and qualitative data from one village each in Kerala and Tamil Nadu during 2010-11. The incident rate ratios and thematic analysis showed that among currently married women under the age of 30 years, those who had been sterilized had significantly higher autonomy in household decision-making and freedom of mobility compared with women who had never used any modern family planning method. Early age at sterilization and low fertility enables women to achieve the social status that is generally attained at later stages in the life-cycle. Policies to capitalize on women's autonomy and free time resulting from early sterilization and low fertility should be adopted in south India.

  10. Research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang; Ouyang Qiongli

    2010-01-01

    Radiation sterilization is widely applied in food processing, pharmaceutical manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. There are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the restrictions of capacity and inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  11. Influence of microwave sterilization on the cutting capacity of carbide burs

    Directory of Open Access Journals (Sweden)

    Laiza Maria Grassi Fais

    2009-12-01

    Full Text Available OBJECTIVE: This study compared the cutting capacity of carbide burs sterilized with microwaves and traditional sterilization methods. MATERIAL AND METHODS: Sixty burs were divided into 5 groups according to the sterilization methods: dry heat (G1, autoclave (G2, microwave irradiation (G3, glutaraldehyde (G4 or control - no sterilization (G5. The burs were used to cut glass plates in a cutting machine set for twelve 2.5-min periods and, after each period, they were sterilized (except G5 following the protocol established for each group. The cutting capacity of the burs was determined by a weight-loss method. Data were analyzed statistically by Kruskal-Wallis and Dunn's test. RESULTS: The means of the cutting amount performed by each group after the 12 periods were G1 = 0.2167 ± 0.0627 g; G2 = 0.2077 ± 0.0231 g; G3 = 0.1980 ± 0.0326 g; G4 = 0.1203 ± 0.0459 g; G5 = 0.2642 ± 0.0359 g. There were statistically significant differences among the groups (p<0.05; only dry heat sterilization was similar to the control. CONCLUSION: Sterilization by dry heat was the method that least affected the cutting capacity of the carbide burs and microwave sterilization was not better than traditional sterilization methods.

  12. The context and limitations of female sterilization services in Pakistan.

    Science.gov (United States)

    Khan, Adnan Ahmad; Khan, Ayesha; Abbas, Khadija; Tirmizi, Syed Farhan Ali; ul Islam, Zia

    2013-04-01

    Female sterilization has long been the most popular method of family planning (FP) in Pakistan, and yet most public health experts feel it contributes little to controlling family size or to population welfare. We used Pakistan Demographic Health Survey (PDHS) data to understand the role female sterilization plays in the overall context of FP in Pakistan. We performed a secondary analysis of data from the PDHS 1990-1 and 2006-7 to study factors that lead to sterilization and trends in the use of the procedure. In addition, census data were multiplied by proportions from PDHS data to estimate the number of women availing sterilization services. Around 1.9 million women in Pakistan are currently sterilized--up from 0.55 million in 1990-1, and around 173,867 undergo the procedure, annually. Women usually receive sterilization after 30 years of age (mean = 39) and after six children. The probability of sterilization increases with age, family size, and urban residence, and is unaffected by poverty, province of residence, or the woman or her husband's education. Most sterilizationis conducted in public sector facilities. Sterilization in Pakistan may be common, but occurs too late to have any significant effect on family size or benefit public health. Future avenues to make this option more useful to women and society would be to improve the repertoire and access and quality of FP services that are available, and to address governance issues that limit the performance and utility of government facilities.

  13. Radiation Sterilization of Two Commonly Culture Media Used for Bacterial Growth

    International Nuclear Information System (INIS)

    El-Hifnawi, H.N.

    2008-01-01

    Radiation sterilization of culture media used for the cultivation of bacteria by Co-60 gamma ray was investigated. Nutrient agar and tryptone glucose yeast extract (TGY) media widely used for the propagation of bacteria were sterilized with 15 kGy dose gamma radiation. Seven different bacterial species were grown as well on the radiation sterilized media as on media sterilized by autoclaving in a conventional way

  14. Eugenics, sterilization, and historical memory in the United States

    Directory of Open Access Journals (Sweden)

    Alexandra Minna Stern

    Full Text Available Abstract From the 1920s to the 1950s, California sterilized approximately 20,000 people in state homes and hospitals based on a eugenic law that authorized medical superintendents to perform reproductive surgeries on patients deemed unfit and “suffering from a mental affliction likely to be inherited.” Working with a unique resource – a dataset created from 19,000 sterilization recommendations – my team and I have reconstructed patterns and experiences of institutionalization of sterilizations. This article presents several of our important initial findings related to ethnic and gender bias in sterilization policies, and reflects on the relevance of the history for contemporary issues in genomics and social justice.

  15. Gamma radiation sterilized amnion: use in ophthalmology

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M. E. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Leon T, Y. [Hospital General Regional 220, IMSS, Paseo Tollocan No. 620, Col. Vertice, Toluca 50150, Estado de Mexico (Mexico); Vazquez M, L., E-mail: esther.martinez@inin.gob.m [Hospital General de Mexico, Dr. Balmis 148, Col. Doctores, 06720 Mexico D. F. (Mexico)

    2010-10-15

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with {sup 60}Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  16. Gamma radiation sterilized amnion: use in ophthalmology

    International Nuclear Information System (INIS)

    Martinez P, M. E.; Leon T, Y.; Vazquez M, L.

    2010-10-01

    Amnion processed at the Radio sterilized Tissue Bank at the National Institute of Nuclear Research, sterilized with 60 Co gamma radiation, have been used in Mexico since 2005 either as a graft to replace the damaged ocular surface, or as a patch to prevent unwanted inflammatory reactions. Patients from the Hospital General de Mexico (HGM) and Instituto Mexicano del Seguro Social (IMSS), suffering diverse pathologies such as keratoconjunctivitis; recurrent pterygium associated with symblepharon; corneal neuro trophic ulcers, chemical and thermal burns, and corneal thinning s, had been successfully treated with irradiated amnion. In the HGM, a clinical prospective study on lesions of the ocular surface of 17 eyes from 15 patients, affected with the above mentioned pathologies, was successful in 88.2%. The results have proven to be excellent as much for cosmetic purposes as for functional ones. Without the treatment, the patients could have suffered a healing after-effect or loss of sight. At IMSS, a controlled clinical randomized trial with 108 eyes from 100 patients, affected with primary nasal pterygium, was performed in 2009. These eyes were treated with radio sterilized amnion and intraoperative mitomycin C to prevent recurrence after excision of the primary pterygium. The preliminary results do not shown adverse reaction, inflammation and pain were significantly reduced radio sterilized amnion also offer security because they do no express antigens HLA-A, B or Dr and the sterile irradiated tissue do not provoke rejection or transmit an infective disease. (Author)

  17. Radiation Fusion Technology for Sewage Sterilization

    International Nuclear Information System (INIS)

    Lee, M. J.; Kim, T. H.; Ryu, S. H.; Jung, I. H.; Lee, O. M.; Kim, T. H.

    2011-01-01

    Environmental regulation for effluent of sewage and wastewater treatment plant is going to be reinforced in terms of ecology toxicity and number of E.coli from 2011. Besides, it has been known that UV technology is not enough to be a sterilization tool due to regrowth of E.coli even after treatment with UV. Therefore it needs a novel technology for both restriction of E.coli regrowth and treatment of toxic materials in order to meet the environmental regulation being enforced. Electron beam has unique capabilities on destruction of chemicals and sterilization of microbial. In this study, field study on destruction of antibiotics and endocrine disruptors, reduction ecological toxicity and E.Coli regrowth was carried out using by mobile electron beam accelerator. Experimental results showed that irradiation on effluent could effectively reduce not only ecology toxicity but regrowth of E.coli by destruction of chemicals and complete sterilization

  18. Comparative transcript profiling of the fertile and sterile flower buds of pol CMS in B. napus.

    Science.gov (United States)

    An, Hong; Yang, Zonghui; Yi, Bin; Wen, Jing; Shen, Jinxiong; Tu, Jinxing; Ma, Chaozhi; Fu, Tingdong

    2014-04-03

    The Polima (pol) system of cytoplasmic male sterility (CMS) and its fertility restoration gene Rfp have been used in hybrid breeding in Brassica napus, which has greatly improved the yield of rapeseed. However, the mechanism of the male sterility transition in pol CMS remains to be determined. To investigate the transcriptome during the male sterility transition in pol CMS, a near-isogenic line (NIL) of pol CMS was constructed. The phenotypic features and sterility stage were confirmed by anatomical analysis. Subsequently, we compared the genomic expression profiles of fertile and sterile young flower buds by RNA-Seq. A total of 105,481,136 sequences were successfully obtained. These reads were assembled into 112,770 unigenes, which composed the transcriptome of the bud. Among these unigenes, 72,408 (64.21%) were annotated using public protein databases and classified into functional clusters. In addition, we investigated the changes in expression of the fertile and sterile buds; the RNA-seq data showed 1,148 unigenes had significantly different expression and they were mainly distributed in metabolic and protein synthesis pathways. Additionally, some unigenes controlling anther development were dramatically down-regulated in sterile buds. These results suggested that an energy deficiency caused by orf224/atp6 may inhibit a series of genes that regulate pollen development through nuclear-mitochondrial interaction. This results in the sterility of pol CMS by leading to the failure of sporogenous cell differentiation. This study may provide assistance for detailed molecular analysis and a better understanding of pol CMS in B. napus.

  19. Mating competitiveness of sterile male Anopheles coluzzii in large cages.

    Science.gov (United States)

    Maïga, Hamidou; Damiens, David; Niang, Abdoulaye; Sawadogo, Simon P; Fatherhaman, Omnia; Lees, Rosemary S; Roux, Olivier; Dabiré, Roch K; Ouédraogo, Georges A; Tripet, Fréderic; Diabaté, Abdoulaye; Gilles, Jeremie R L

    2014-11-26

    Understanding the factors that account for male mating competitiveness is critical to the development of the sterile insect technique (SIT). Here, the effects of partial sterilization with 90 Gy of radiation on sexual competitiveness of Anopheles coluzzii allowed to mate in different ratios of sterile to untreated males have been assessed. Moreover, competitiveness was compared between males allowed one versus two days of contact with females. Sterile and untreated males four to six days of age were released in large cages (~1.75 sq m) with females of similar age at the following ratios of sterile males: untreated males: untreated virgin females: 100:100:100, 300:100:100, 500:100:100 (three replicates of each) and left for two days. Competitiveness was determined by assessing the egg hatch rate and the insemination rate, determined by dissecting recaptured females. An additional experiment was conducted with a ratio of 500:100:100 and a mating period of either one or two days. Two controls of 0:100:100 (untreated control) and 100:0:100 (sterile control) were used in each experiment. When males and females consort for two days with different ratios, a significant difference in insemination rate was observed between ratio treatments. The competitiveness index (C) of sterile males compared to controls was 0.53. The number of days of exposure to mates significantly increased the insemination rate, as did the increased number of males present in the untreated: sterile male ratio treatments, but the number of days of exposure did not have any effect on the hatch rate. The comparability of the hatch rates between experiments suggest that An. coluzzii mating competitiveness experiments in large cages could be run for one instead of two days, shortening the required length of the experiment. Sterilized males were half as competitive as untreated males, but an effective release ratio of at least five sterile for one untreated male has the potential to impact the fertility of

  20. Improving hybrid seed production in corn with glyphosate-mediated male sterility.

    Science.gov (United States)

    Feng, Paul C C; Qi, Youlin; Chiu, Tommy; Stoecker, Martin A; Schuster, Christopher L; Johnson, Scott C; Fonseca, Augustine E; Huang, Jintai

    2014-02-01

    Hybrid corn varieties exhibit benefits associated with heterosis and account for most of the corn acreage in the USA. Hybrid seed corn is produced by crossing a female parent which is male-sterile and therefore incapable of self-pollination with a male parent as the pollen donor. The majority of hybrid seed corn is produced by mechanical detasseling which involves physically removing the tassel, a process that is laborious and costly. Glyphosate-resistant corn was developed via expression of a glyphosate insensitive 5-enolpyruvyl-shikimate 3-phosphate synthase enzyme (CP4-EPSPS). Experimentation with molecular expression elements resulted in selective reduction of CP4-EPSPS expression in male reproductive tissues. The resulting plant demonstrated sterile tassel following glyphosate application with little to no injury to the rest of the plant. Using (14)C-glyphosate as a marker, we also examined the translocation of glyphosate to the tassel via spray application in a track sprayer to simulate field application. The results allowed optimization of spray parameters such as dose, spray timing and target to maximize tassel delivery of glyphosate for efficient sterilization. The Roundup hybridization system (RHS) is a novel process for hybrid seed production based on glyphosate-mediated male sterility. RHS replaces mechanical detasseling with glyphosate spray and greatly simplifies the process of hybrid seed corn production. © 2013 Society of Chemical Industry.

  1. Comparative analysis of ampoules and vials in sterile and conventional packaging as to microbial load and sterility test.

    Science.gov (United States)

    Freitas, Raphael Ribeiro de Aquino; Tardelli, Maria Angela

    2016-05-24

    To compare sterility and microbial (bacteria and fungi) load in the outer part of hyperbaric bupivacaine (Neocaína®) in ampoule and bupivacaine in vial, in conventional and sterile pack formulations. The sterile packs were divided into two groups: G1 (n=16) with ampoules and G2 (n=16) with vials. Conventional formulations were divided into two groups, being G3 (n=16) with ampoules and G4 (n=16) with vials. The ampoules and vials were opened and had their content drawn. The empty bottles were then placed in sterile plastic bags and sent for analysis of microbial load (bacteria and fungi) and sterility testing. Data were analyzed using the χ2 test with Yates correction, and 95% confidence interval. G1 and G2 showed no bacterial growth when compared to conventional groups (pgrupos, sendo que o G1 (n=16) continha as ampolas e o G2 (n=16), os frascos-ampola. As apresentações convencionais foram distribuídas em dois grupos, a saber G3 (n=16) com as ampolas e G4 (n=16) com os frascos-ampola. As ampolas e os frascos-ampolas eram abertos e tinham seu conteúdo aspirado. Os frascos vazios eram, então, acondicionados em sacos plásticos estéreis e enviados para análise quanto à carga microbiana (bactérias e fungos), bem como para o teste de esterilidade. Os dados foram analisados por meio do teste χ2 com correção Yates com intervalo de confiança de 95%. Os grupos G1 e G2 não apresentaram crescimento bacteriano quando comparado aos grupos convencionais (pgrupos. O uso de embalagens estéreis (sterile pack) diminui a carga microbiana dos frascos de envasamentos, o que diminuiria a chance de exposição a uma potencial contaminação da solução anestésica.

  2. Electric dipole moments of charged leptons with sterile fermions

    International Nuclear Information System (INIS)

    Abada, Asmaa; Toma, Takashi

    2016-01-01

    We address the impact of sterile fermions on charged lepton electric dipole moments. Any experimental signal of these observables calls for scenarios of physics beyond the Standard Model providing new sources of CP violation. In this work, we consider a minimal extension of the Standard Model via the addition of sterile fermions which mix with active neutrinos and we derive the corresponding analytical expressions for the electric dipole moments of charged leptons at two-loop order. Our study reveals that, in order to have a non-vanishing contribution in this framework, the minimal extension necessitates the addition of at least 2 sterile fermion states to the Standard Model field content. Our conclusion is that sterile neutrinos can give significant contributions to the charged lepton electric dipole moments, some of them lying within present and future experimental sensitivity if the masses of the non-degenerate sterile states are both above the electroweak scale. The Majorana nature of neutrinos is also important in order to allow for significative contributions to the charged lepton electric dipole moments. In our analysis we impose all available experimental and observational constraints on sterile neutrinos and we further discuss the prospect of probing this scenario at low and high energy experiments.

  3. Electric dipole moments of charged leptons with sterile fermions

    Energy Technology Data Exchange (ETDEWEB)

    Abada, Asmaa; Toma, Takashi [Laboratoire de Physique Théorique, CNRS, University Paris-Sud, Université Paris-Saclay, 91405 Orsay (France)

    2016-02-26

    We address the impact of sterile fermions on charged lepton electric dipole moments. Any experimental signal of these observables calls for scenarios of physics beyond the Standard Model providing new sources of CP violation. In this work, we consider a minimal extension of the Standard Model via the addition of sterile fermions which mix with active neutrinos and we derive the corresponding analytical expressions for the electric dipole moments of charged leptons at two-loop order. Our study reveals that, in order to have a non-vanishing contribution in this framework, the minimal extension necessitates the addition of at least 2 sterile fermion states to the Standard Model field content. Our conclusion is that sterile neutrinos can give significant contributions to the charged lepton electric dipole moments, some of them lying within present and future experimental sensitivity if the masses of the non-degenerate sterile states are both above the electroweak scale. The Majorana nature of neutrinos is also important in order to allow for significative contributions to the charged lepton electric dipole moments. In our analysis we impose all available experimental and observational constraints on sterile neutrinos and we further discuss the prospect of probing this scenario at low and high energy experiments.

  4. Shelf life prediction of radiation sterilized polymeric materials

    International Nuclear Information System (INIS)

    Sandford, Craig; Woo, Lecon

    1988-01-01

    The functional properties of many polymers employed in medical disposables are unaffected by sterilizing doses of ionizing radiation. However, some materials (PVC, polypropylene, cellulosics, etc.) undergo undesirable changes which continue to occur for the shelf life of the product. In many cases, conventional accelerated aging techniques do not accurately predict the real time properties of the materials. As real time aging is not generally practical, it has become necessary to develop accelerated aging techniques which can predict the functional properties of a material for the shelf life of the product. This presentation will address issues involved in developing these tests. Real time physical property data is compared to data generated by various acceleration methods. (author)

  5. LED surgical lighting system with multiple free-form surfaces for highly sterile operating theater application.

    Science.gov (United States)

    Liu, Peng; Zhang, Yaqin; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-06-01

    Although the ventilation system is widely employed in the operating theater, a strictly sterile surgical environment still cannot be ensured because of laminar disturbance, which is mainly caused by the surgical lighting system. Abandoning traditional products, we propose an LED surgical lighting system, which can alleviate the laminar disturbance and provide an appropriate lighting condition for surgery. It contains a certain amount of LED lens units, which are embedded in the ceiling and arranged around the air supply smallpox. The LED lens unit integrated with an LED light source and a free-form lens is required to produce a uniform circular illumination with a large tolerance to the change of lighting distance. To achieve such a dedicated lens, two free-form refractive surfaces, which are converted into two ordinary differential equations by the design method presented in this paper, are used to deflect the rays. The results show that the LED surgical lighting system can provide an excellent illumination environment for surgery, and, apparently, the laminar disturbance also can be relieved.

  6. Remodeling of ACL Allografts is Inhibited by Peracetic Acid Sterilization

    Science.gov (United States)

    Gonnermann, Johannes; Kamp, Julia; Przybilla, Dorothea; Pruss, Axel

    2008-01-01

    Sterilization of allografts for anterior cruciate ligament (ACL) reconstruction has become an important prerequisite to prevent disease transmission. However, current sterilization techniques impair the biological or mechanical properties of such treated grafts. Peracetic acid (PAA) has been successfully used to sterilize bone allografts without these disadvantages and does not impair the mechanical properties of soft tissue grafts in vitro. We asked whether PAA sterilization would influence recellularization, restoration of crimp length and pattern, and revascularization of ACL grafts during early healing. We used an in vivo sheep model for open ACL reconstruction. We also correlated the histologic findings with the restoration of anteroposterior stability and structural properties during load-to-failure testing. PAA slowed remodeling activity at 6 and 12 weeks compared to nonsterilized allografts and autografts. The mechanical properties of PAA grafts were also reduced compared to these control groups at both time points. We conclude PAA sterilization currently should not be used to sterilize soft tissue grafts typically used in ACL reconstruction. PMID:18491201

  7. Electron beam sterilization of water discharged from sewage

    International Nuclear Information System (INIS)

    Miyata, Teijiro; Arai, Hidehiko; Tokunaga, Okihiro; Machi, Sueo; Kondo, Masaki; Minemura, Takashi; Nakao, Akio; Seike, Yasuhiko.

    1989-01-01

    At present, the water treated at city sewerages is discharged to rivers after the chlorine sterilization, but it was clarified recently that this chlorine treatment produces carcinogenic organic chlorine compounds, and residual chlorine exerts harmful effect to aquatics, therefore, it is desirable to develop the sterilization techniques substituting for chlorine treatment. Already many reports elucidated that irradiation is effective for the sterilization of the water discharged from sewerage. However, as the technical subject for putting radiation process in practical use, the treatment of large quantity was a problem. Recently by the progress of the technology of manufacturing electron accelerators, the equipment with large power output which can treat in large quantity was developed, and it has become applicable also to sewage treatment. Therefore, the authors examined the practicality of electron beam process as the substitute technology for chlorine sterilizaiton. In the case of using electron beam, though the power output of accelerators is large, the flight range of electron beam in water is short. The comparison of the sterilization effect of electron beam with that of Co-60 gamma ray, the effects of water depth, discharged water quality and water velocity on the sterilization effect and so on were experimentally examined. (K.I.)

  8. Sterilization of microbes by using various plasma jets

    Energy Technology Data Exchange (ETDEWEB)

    Uhm, Han S.; Choi, Eun H.; Cho, Guang S. [Kwangwoon University, Seoul (Korea, Republic of); Hong, Yong C. [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2012-03-15

    Sterilization of various microbes was carried out by using several plasma jets. Argon plasma jets penetrate deep into ambient air and create a path for oxygen radicals to sterilize microbes including spores. A sterilization experiment with bacterial endospores indicates that an argon-oxygen plasma jet very effectively kills endospores of Bacillus atrophaeus (ATCC 9372), thereby demonstrating its capability to clean surfaces and its usefulness for reinstating contaminated equipment as free from toxic biological agents. The key element of the sterilization is oxygen radicals. The penciltype configuration produces a long, cold plasma jet capable of reaching 3.5 cm and having various excited plasma species shown through the optical emission spectrum. Operation of an air plasma jet at 2 W in a pencil-type electrode provides an excellent opportunity for sterilization of microbes. An electron microscope was used to observe the effects of the plasma on bacterial cell morphology. Transmission electron micrographs showed morphological changes in E. coli cells treated with an atmospheric plasma at 75 W for 2 min. The treated cells had severe cytoplasmic deformations and leakage of bacterial chromosome. The chromosomal DNA was either attached to the bacterial cells or released freely into the surrounding medium. The results clearly explain the loss of viability of bacterial cells after plasma treatment.

  9. Surgical infection in a videolaparoscopic cholecystectomy when using peracetic acid for the sterilization of instruments.

    Science.gov (United States)

    de Melo, Edluza Maria Viana Bezerra; Leão, Cristiano de Souza; Andreto, Luciana Marques; de Mello, Maria Júlia Gonçalves

    2013-01-01

    To determine the frequency of surgical site infection in patients undergoing laparoscopic cholecystectomy with instruments sterilized by peracetic acid. We conducted a retrospective, cohort, descriptive, cross-sectional study. Peracetic acid has been used for sterilization following the protocol recommended by the manufacturer. We observed the criteria and indicators of process and structure for preventing surgical site infection pre and intraoperatively. For epidemiological surveillance, outpatient visits were scheduled for the 15th and between the 30th and 45th days after discharge. Among the 247 patients, there were two cases of surgical site infection (0.8%). One patient was readmitted to systemic antibiotic therapy and percutaneous puncture; in the other the infection was superficial and followed at the clinic. Ethical issues prevent the conduction of a prospective study because of peracetic acid have been banned for the sterilization of instruments that penetrate organs and cavities. Nevertheless, these results encourage prospective case-control studies comparing its use (historical control) with ethylene oxide sterilization.

  10. Degradation and stability of polycarbonate sterilized by gamma rays

    International Nuclear Information System (INIS)

    Araujo, E.S.; Guedes, S.M.L.

    1995-01-01

    The purpose of this paper is to study the behavior of the polycarbonate (poly (bis phenol-A carbonate)) when it is sterilized by gamma rays because undesirable discoloration appears. Aromatic polycarbonates are amorphous polymers usually prepared from bis phenols and phosgene by interfacial polymerization. They are employed in medical applications, including blood filters, dialyzers, oxygenators and sterilizing equipment. At present, the best process for sterilization of medical supplies is present, the best process for sterilization of medical supplies is gamma irradiation. The two major effects of γ-radiation in polymers are crosslinking and main chain scission. Both effects coexist and either one may predominate depending on the chemical structure of the polymer and the conditions of irradiation. (author). 5 refs, 6 figs, 1 tab

  11. Management of long-term and reversible hysteroscopic sterilization: a novel device with nickel-titanium shape memory alloy

    Science.gov (United States)

    2014-01-01

    Background Female sterilization is the second most commonly used method of contraception in the United States. Female sterilization can now be performed through laparoscopic, abdominal, or hysteroscopic approaches. The hysteroscopic sterilization may be a safer option than sterilization through laparoscopy or laparotomy because it avoids invading the abdominal cavity and undergoing general anaesthesia. Hysteroscopic sterilization mainly includes chemical agents and mechanical devices. Common issues related to the toxicity of the chemical agents used have raised concerns regarding this kind of contraception. The difficulty of the transcervical insertion of such mechanical devices into the fallopian tubes has increased the high incidence of device displacement or dislodgment. At present, Essure® is the only commercially available hysteroscopic sterilization device being used clinically. The system is irreversible and is not effective immediately. Presentation of the hypothesis Our new hysteroscopic sterility system consists of nickel-titanium (NiTi) shape memory alloy and a waterproof membrane. The NiTi alloy is covered with two coatings to avoid toxic Ni release and to prevent stimulation of epithelial tissue growth around the oviducts. Because of the shape memory effect of the NiTi alloy, the device works like an umbrella: it stays collapsed at low temperature before placement and opens by the force of shape memory activated by the body temperature after it is inserted hysteroscopically into the interstitial tubal lumen. The rim of the open device will incise into interstitial myometrium during the process of unfolding. Once the device is fixed, it blocks the tube completely. When the patient no longer wishes for sterilization, the device can be closed by perfusing liquid with low temperature into the uterine cavity, followed by prospective hysteroscopic removal. After the device removal, the fallopian tube will revert to its physiological functions. Testing the

  12. Guide for dosimetry for sterile insect release programs. 2. ed.

    International Nuclear Information System (INIS)

    2004-01-01

    This guide outlines dosimetric procedures to be followed for the radiation sterilization of live insects for use in pest management programs. The primary use of irradiated, reproductively sterile insects is in the Sterile Insect Technique, where large numbers of sterile insects are released into the field to mate with and thus control pest populations of the same species. A secondary use of sterile insects is as benign hosts for rearing insect parasitoids. The procedures outlined in this guide will help ensure that insects processed with ionizing radiation from gamma, electron, or X-ray sources receive absorbed doses within a predetermined range. Information on effective dose ranges for specific applications of insect sterilization, or on methodology for determining effective dose ranges, is not within the scope of this guide. Note: Dosimetry is only one component of a total quality control program to ensure that irradiated insects are adequately sterilized and sufficiently competitive or otherwise suitable for their intended purpose. This guide covers dosimetry in the irradiation of insects for these types of irradiators: self-contained dry-storage 137 Cs or 60 Co irradiators, large-scale gamma irradiators, and electron accelerators. Additional, detailed information on dosimetric procedures to be followed in installation qualification, operational qualification, performance qualification, and routine product processing can be found in ISO/ASTM Practices 51608 (X-ray [bremsstrahlung] facilities), 51649 (electron beam facilities), 51702 (large-scale gamma facilities), and ASTM Practice E 2116 (self-contained dry-storage gamma facilities). The absorbed dose for insect sterilization is typically within the range of 20 Gy to 600 Gy

  13. Radiation sterilization of hydrocortisone acetate

    International Nuclear Information System (INIS)

    Charef, A.; Boussaha, A.

    1989-09-01

    The feasibility of using high energy ionizing radiation for the sterilization of hydrocortisone acetate was investigated. Hydrocortisone acetate in the form of powder was exposed to different dose levels of gamma radiation using a Cobalt-60 source. The irradiated samples were examined by various physico-chemical techniques in order to detect possible radiolysis products. It was of interest to know if one could insure sterility and retain biological properties of the drug by suitable choice of radiation dose. The results showed that a 10 KGy radiation dose causes no change in the physico-chemical properties of the drug and is sufficient to obtain contaminant-free product

  14. Sterilization by ionizing radiation comparative evaluation

    International Nuclear Information System (INIS)

    Tata, A.; Giuliani, S.

    1996-01-01

    Sterilization of surgical and medical devices by ionizing radiation (gamma or accelerated electron beams) is currently regarded as one of the main industrial-scale applications of radiation technology processes. Considering the most widely utilized chemical-physical methods (i.e. ethylene oxide (EtO) fumigation and radiation treatment), about 10-12 millions m(3) of surgical and medical devices are estimated to be processed yearly all around the world, of which 7 on beams. Due to the increasing demand for reusable and single-use devices, and the need of assuring their sterility in order to prevent, as much as possible, the diffusion of serious infective diseases (among which for instance Aids), the market of sterilization of these items is considerably expanding. In the general depicted scenario, radiation technologies are expected to gain a leading role, even a part from their economic attractiveness, as an alternative to EtO treatment, which is more and more considered as responsible for increasing environmental, social and public health problems

  15. Searching for a strategy to gamma-sterilize Portuguese cork stoppers - preliminary studies on bioburden, radioresistance and sterility assurance level

    International Nuclear Information System (INIS)

    Botelho, M.L.; Almeida-Vara, E.; Andrade, M.E.; Tenreiro, R.

    1988-01-01

    A gamma radiation plant will start running next year in Portugal, to sterilize medical devices and wine cork stoppers. As Portugal is the first world producer, manufacturer and exporter of wine cork stoppers, an efficient sterilizing procedure is required to overcome moulding from long term shipping. Preliminary research on cork stoppers bioburden and microflora radioresistance allowed to establish reliable D 10 and Sterility Assurance Level (SAL) values. Studied samples showed an initial average contamination of about 10 4 c.f.u. per cork stopper. The determined D 10 values for fungi were not higher than 2 kGy. In these conditions, a SAL of 10 -4 can be expected when the product is treated at a minimum absorbed dose of 15 kGy. (author)

  16. Surface sterilization method for reducing microbial contamination of ...

    African Journals Online (AJOL)

    An effective disinfection method for strawberry (Fragaria x ananassa Duch.) cv. Senga Sengana micropropagation using runner tips and nodal segments as explants was developed. The explants were surface sterilized with different sterilants for different durations. The present studies on the effect of different regimes of ...

  17. Thiamine losses during storage of pasteurised and sterilized model systems of minced chicken meat with addition of fresh and oxidized fat, and antioxidants.

    Science.gov (United States)

    Szymandera-Buszka, Krystyna; Hęś, Marzanna; Waszkowiak, Katarzyna; Jędrusek-Golińska, Anna

    2014-01-01

    The aim of the study was to determine the effect of pasteurisation and sterilization of model systems of minced chicken meat in the presence of low or high-oxidised pork lard, soy and sunflower oil, as well as casein hydrolysate and rosemary extract, on losses of thiamine in model systems. In the samples, the thiamine content was analysed periodically by thiochromium method, as well as rate of lipid oxidation based on measurement of peroxide value (PV) by iodometric method and p-anisidine value (AV) by spectrophotometric method. It was observed that the thiamine losses in model systems of minced chicken after pasteurisation (61-71%) were higher than after sterilization (57-67%). Introduction of high-oxidised fat increased the total thiamine losses both during thermal processing and storage of meat samples (to 23%). A strong relationship was established between thiamine losses and rate of fat oxidation. The lowest total thiamine losses were observed in the samples with low-oxidised pork lard. Antioxidant addition (rosemary extract or casein hydrolysate) into meat samples limited the thiamine losses. However, the effect depended on oxidation of fat that was mixed with meat. In the samples with low-oxidised fat, higher protective effect was found for rosemary extract (7-11%). In the samples with high-oxidised fat, casein hydrolysate was superior to rosemary extract (14%). In order to increase the stability of thiamine in pasteurized or sterilized meat products with fats, the influence of fat type and its oxidative stability should be taken under consideration. Moreover, the addition of rosemary extract or casein hydrolysate has impact on the thiamine losses since it slows down lipid oxidation to a significant extent.

  18. Cross-cultural attitudes toward voluntary sterilization.

    Science.gov (United States)

    Hong, S

    1985-06-01

    . Cultural traits such as machismo and son preference tend to be associated with negative attitudes toward sterilization; yet, VS prevalence is high in China and Panama despite the presence of a strong preference for sons in the former country and of machismo attitudes in the latter country. Acceptance of VS as a form of birth control appears to be increasing throughout the world. This trend will probably become stronger as improvements are made in VS technologies and Vs delivery systems.

  19. Effect of gamma irradiation on fertility of potato tuber moth males and study of inherited sterility phenomena in partially sterile males

    International Nuclear Information System (INIS)

    Saour, G.; Makee, H.

    1996-01-01

    Newly emerged adult males (0-18 h) potato tuber moth (PTM) phthorimaea operculella (Zeller) (Lepidoptera: Gelechiidae) were irradiated with various doses of gamma irradiation ranging from 5 to 45 krad. Sterility in order of 91% was induced when males were irradiated with a dose of 45 Krad. Longevity of male PTM was not affected by the application of irradiation, while mating ability and frequency of mating of the males irradiated with 25, 35 and 45 Krad were decreased. The mean number of eggs laid by females mated with males irradiated at 35 and 45 Krad was lower than the control. When males PTM were irradiated with high doses their competitiveness values were reduced, while the competitiveness was increased when the sex ratio of irradiated males to normal males was increased, specially with ration 1 : 10 : 1 (Normal male: Irradiated males: Normal female). Application of 15 Krad dose permitted, the ability to obtain a desired level of male sterility with acceptable reduction in its competitiveness. The inherited sterility phenomena in partially sterile males irradiated with 10-15 and 20 Krad was studied. Sterility in F1 progeny was higher than that in their irradiated male parents. The sex ratio of F1 progeny was distorted in favour of the males. (author). 24 refs., 5 figs

  20. Effect of gamma irradiation on fertility of potato tuber moth males and study of inherited sterility phenomena in partially sterile males

    Energy Technology Data Exchange (ETDEWEB)

    Saour, G; Makee, H [Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Radiation Agriculture

    1996-01-01

    Newly emerged adult males (0-18 h) potato tuber moth (PTM) phthorimaea operculella (Zeller) (Lepidoptera: Gelechiidae) were irradiated with various doses of gamma irradiation ranging from 5 to 45 krad. Sterility in order of 91% was induced when males were irradiated with a dose of 45 Krad. Longevity of male PTM was not affected by the application of irradiation, while mating ability and frequency of mating of the males irradiated with 25, 35 and 45 Krad were decreased. The mean number of eggs laid by females mated with males irradiated at 35 and 45 Krad was lower than the control. When males PTM were irradiated with high doses their competitiveness values were reduced, while the competitiveness was increased when the sex ratio of irradiated males to normal males was increased, specially with ration 1 : 10 : 1 (Normal male: Irradiated males: Normal female). Application of 15 Krad dose permitted, the ability to obtain a desired level of male sterility with acceptable reduction in its competitiveness. The inherited sterility phenomena in partially sterile males irradiated with 10-15 and 20 Krad was studied. Sterility in F1 progeny was higher than that in their irradiated male parents. The sex ratio of F1 progeny was distorted in favour of the males. (author). 24 refs., 5 figs.

  1. American Sterilization: The Racist Justifications for Sterilization in the United States

    OpenAIRE

    Trevor Price

    2016-01-01

    An investigative analysis into anthropometrics, sterilization, eugenics, and other forms of scientific racism used to justify white supremacy and racial thought in the 19th and 20th centuries in the United States. The Tuskegee syphilis study, Darwinistic ideals, and neo-Lamarckian thoughts are critically analyzed as justifications for institutional racism.

  2. The causes of genetic male sterility in 3 soybaen lines.

    Science.gov (United States)

    Rubaihayo, P R; Gumisiriza, G

    1978-11-01

    The cause of male sterility in 3 soybean lines, TGM 103-1, N-69-2774 and TGM 242-4 was studied. In TGM 103-1, which was both male and female sterile, two different abnormalities were associated with sterility. Precocious movement of a few chromosomes at the metaphase I stage resulted into the production of non-functional pollen while cells which underwent apparent normal meiotic division had disintergration of the tapetal cell wall immediately after the free microspore stage leading to the starvation and subsequent death of the developing microspores. In lines N-69-2774 and TGM 242-4, both of which were partially sterile, male sterility resulted from a failure of cytokinesis after the telophase II stage. Meiosis proceeded normally but the 4 microspores after telophase II failed to separate into pollen grains and degenerated thereafter.

  3. [Assessment of disinfection and sterilization processes in dental practice as an important factors in prevention of infections].

    Science.gov (United States)

    Podgórska, Marta; Jakimiak, Bozenna; Röhm-Rodowald, Ewa; Chojecka, Agnieszka

    2009-01-01

    The dental health-care settings is an environment where disease transmission occurs easily. Prevention of cross infection is therefore a crucial aspect of dental practice and dental clinic stuffmust adopt certain basic routines while practicing. Infections may be transmitted in the dental operatory through direct contact with blood, oral fluids or other secretions; via indirect contact with contaminated instruments, equipment or environmental surfaces; or by contact with airborne contaminants present in either droplet splatter or aerosols of oral and respiratory fluids. Strategies to prevent dental patient infections have focused on disinfection and sterilization. This study evaluates basic routines in prevention of cross-infection in the dentistry. The sample comprised 100 dentists, who completed questionnaires. Based on inquires the conditions for disinfection and sterilization of medical devices were assessed. The following issues were taken into consideration: the way of disinfection and preparation of the disinfectants, the localization of disinfection, preparing to disinfection, washing and packing of dental devices, the frequency of disinfection, methods of sterilization and the monitoring system, type of sterilizers and the available cycles. The dental practices are well equiped to proceed the steam sterilization, but 33% of dentists don't know the available cycles in their autoclaves. Only 35% of them made sterilization process protocols. Very common are three failures of instruments disinfections: multiple use of disinfectant, adding of disinfectant, adding new instruments. There is still need for improvement in disinfection and sterilization in dental practice, especially including: monitoring and documentation of sterilization process, proper use of disinfectants according to manufactures instructions, frequent disinfection of surfaces which contact with patients. Dental stuff should take part in advanced training courses about disinfection and

  4. A research on industrial development of radiation sterilization in Sichuan

    International Nuclear Information System (INIS)

    Chen Xun; Zhu Rong; Chen Jigang

    2010-01-01

    Radiation sterilization is widely applied in food processing, Pharmaceutical Manufacturing and medical instrumentation producing. As this industry offers service to related corporations, its development depends largely on the market scale of the relevant industries. This article mainly discusses the balance point between the capacity of radiation sterilization and the requirement of its market. There are less than 1% of the companies in Sichuan which using radiation sterilization for its products, broad prospects has shown in this field. The output value of radiation sterilization industry reached 0.1% of the GDP in some advanced countries (America and Japan...), under this standard, its output value in Sichuan province would be RMB1.2 hundred million, but now our capacity and scale of this industry is less than RMB40million.Research shows: there are 3 key points to make its output value reach 0.1% of the GDP in Sichuan: 1. Breaking the 'bottleneck' restrictions of capacity and Inappropriate resources distribution. 2. Promoting the technique of radiation sterilization, guiding corporation to reduce their dependence on food additive from the perspective of food safety, make effective implantation of radiation sterilization into their manufacture processes. 3. Increasing publicity for radiation sterilization, eliminating scared mentality among customer on nuclear technology, helping manufacturing corporations to establish green environmental protection brand, directing our customer to a more healthy awareness. (authors)

  5. Effect of fermentation and sterilization on anthocyanins in blueberry.

    Science.gov (United States)

    Nie, Qixing; Feng, Lei; Hu, Jielun; Wang, Sunan; Chen, Haihong; Huang, Xiaojun; Nie, Shaoping; Xiong, Tao; Xie, Mingyong

    2017-03-01

    Blueberry products have various health benefits due to their high content of dietary anthocyanins. The aim of this study was to investigate the impact of fermentation and sterilization on total anthocyanin content, composition and some quality attributes of blueberry puree. The blueberry puree used here was fermented for 40 h at 37 °C by Lactobacillus after sterilization. The method of ultra-performance liquid chromatography-mass spectrometry was optimized for the rapid analysis of anthocyanins. Quality attributes including pH, color, total soluble solids and viscosity were measured. A total of 21 anthocyanins and five anthocyanidins were quantified by ultra-performance liquid chromatography. Fermented blueberry had reduced total anthocyanin content (29%) and levels of individual anthocyanins compared with fresh blueberry. Total anthocyanin content was decreased 46% by sterilization, and different degradation behavior of individual anthocyanin was appeared between fermented and sterilized-fermented blueberry puree. Fermentation and sterilization decreased the total soluble solids and pH and changed color parameters, while minimally influencing viscosity. The loss of total anthocyanin content by fermentation was related to the unstable structure of blueberry anthocyanins. Anthocyanins are sensitive to temperature (>80 °C), and degradation of anthocyanins by sterilization in blueberry should be considered in the fermentation procedure. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  6. Gamma radiations an effective way of monoclonal antibodies sterilization

    International Nuclear Information System (INIS)

    Lenay Barrera Barroso, Lenay; Otero Abreu, Isabel; Rodriguez Napoles, Dania; Bulte Ocanna, Dubhe; Caballero, Idania

    2006-01-01

    The sterilization for radiations of pharmaceutical products is an effective, sure and reliable procedure; that it have been proving technically and grateful for different pharmacopoeia. The Monoclonal Antibodies (Acm) produced in the Center of Molecular Immunology (CIM) are products parenteral for the one which results indispensable that they complete the requirements of established sterility. The radio sterilization result the method more recommend for the sterilization of the Acm deep drying, due to the contained first floor of humidity remnant that minimizes the formation of sub-product that they affect their properties. With the objective of proposing a good dose of irradiation for the sterilization, we were carried out a study of the radius sensibility so much of the product like of the polluting of greater frequency of isolation of the clean area of the CIM. The characterization of the radius sensibility of the different micro- organisms was determined by D 10 characteristic of each isolated strains. From the developed studies the Gram-positive rods endospore-forming were the most resistant strains at the deep drying, the radiations and they were of the greater frequency of apparition in the carried out isolations. We could conclude that utilizing a dose of 10 kGy it is possible to eliminate of the pollution more radio resistant, assuring the sterility required in the product, and without inducing effects under desire radiolytic in the same

  7. Improved Sterilization of Sensitive Biomaterials with Supercritical Carbon Dioxide at Low Temperature.

    Directory of Open Access Journals (Sweden)

    Anne Bernhardt

    Full Text Available The development of bio-resorbable implant materials is rapidly going on. Sterilization of those materials is inevitable to assure the hygienic requirements for critical medical devices according to the medical device directive (MDD, 93/42/EG. Biopolymer-containing biomaterials are often highly sensitive towards classical sterilization procedures like steam, ethylene oxide treatment or gamma irradiation. Supercritical CO₂ (scCO₂ treatment is a promising strategy for the terminal sterilization of sensitive biomaterials at low temperature. In combination with low amounts of additives scCO₂ treatment effectively inactivates microorganisms including bacterial spores. We established a scCO₂ sterilization procedure under addition of 0.25% water, 0.15% hydrogen peroxide and 0.5% acetic anhydride. The procedure was successfully tested for the inactivation of a wide panel of microorganisms including endospores of different bacterial species, vegetative cells of gram positive and negative bacteria including mycobacteria, fungi including yeast, and bacteriophages. For robust testing of the sterilization effect with regard to later application of implant materials sterilization all microorganisms were embedded in alginate/agarose cylinders that were used as Process Challenge Devices (PCD. These PCD served as surrogate models for bioresorbable 3D scaffolds. Furthermore, the impact of scCO₂ sterilization on mechanical properties of polysaccharide-based hydrogels and collagen-based scaffolds was analyzed. The procedure was shown to be less compromising on mechanical and rheological properties compared to established low-temperature sterilization methods like gamma irradiation and ethylene oxide exposure as well as conventional steam sterilization. Cytocompatibility of alginate gels and scaffolds from mineralized collagen was compared after sterilization with ethylene oxide, gamma irradiation, steam sterilization and scCO₂ treatment. Human

  8. Radiation sterilization of pharmaceuticals (eg chloramphenicol)

    International Nuclear Information System (INIS)

    Zeegers, F.; Tilquin, B.

    1991-01-01

    In connection with the ongoing world-wide application of irradiation as a new technology for sterilization, the identification of the drugs products is very important. Introduction of radiosterilization of pharmaceuticals is proceeding at a slower rate than that for disposable medical supplies; it is the responsibility of the manufacturer to prove that degradation of products is safe. Major advantages in the use of radiation as a sterilization procedure are high penetrating power, small temperature rise, ease of control and minimal degradation of irradiated solid drugs [fr

  9. Evaluation of Effects of Sterilization on Mechanical Properties of Orthodontic Wires

    Directory of Open Access Journals (Sweden)

    Sridhar Kannan

    2012-01-01

    Results: Dry heat sterilization, autoclave, 2% glutaraldehyde solution had no effect on ultimate tensile strength, 0.1% yield strength, modulus of elasticity and percentage elongation of stainless steel and elgiloy wires. Tensile strength and yield strength of Nitinol and b-titanium wires together with percentage elongation of b-titanium wires significantly increased following dry heat sterilization and autoclave. No detrimental effects on properties of wires were observed. These sterilization procedures could be safely recommended for sterilization of orthodontic wires.

  10. Multiple matings among glossina and the sterile male technique

    International Nuclear Information System (INIS)

    Pinhao, R.C.

    1980-01-01

    The fact that multiple matings are a common phenomenon among glossina turns the sterile male technique into a competition not between adult insects but between two types of sperm, and the proportion of females inseminated with the one or the other is given by the binomial (p+q)sup(n), where p is the percentage of normal males, q the percentage of sterile males and n the average number of matings per female. However, multiple matings cannot damage the effectiveness of the technique unless two conditions are present either separately or simultaneously: precocious death of the spermatozoa and reduced inseminating potential among the sterile males. Study of the factors which can alter the inseminating potential is thus important for those who wish to use the sterile male technique. These factors are of three kinds: factors connected with quality, with quantity and with availability. The first are associated with the nature and intensity of the alterations brought about in the spermatozoa by the sterilizing agent, the second with possible variations in the amount of sperm reaching the spermotheca, the third with the behaviour of the sterile males in the nature - that is, the question whether sterilization has a favourable or unfavourable influence on their chances of mating with wild females. The author describes his observations of the quantity of sperm produced by Glossina morsitans submorsitans males from the colony reared at the Institute for Tropical Hygiene and Medicine in Lisbon, compares them with the observations of other authors and discusses their practical significance. Specific research is suggested. Advantages from assessing the behaviour of colonies not by female productivity but by male inseminating potential, and appropriate laboratory techniques

  11. Gene, protein, and network of male sterility in rice

    OpenAIRE

    Wang, Kun; Peng, Xiaojue; Ji, Yanxiao; Yang, Pingfang; Zhu, Yingguo; Li, Shaoqing

    2013-01-01

    Rice is one of the most important model crop plants whose heterosis has been well-exploited in commercial hybrid seed production via a variety of types of male-sterile lines. Hybrid rice cultivation area is steadily expanding around the world, especially in Southern Asia. Characterization of genes and proteins related to male sterility aims to understand how and why the male sterility occurs, and which proteins are the key players for microspores abortion. Recently, a series of genes and prot...

  12. Mechanisms of male sterility in higher plants

    Energy Technology Data Exchange (ETDEWEB)

    Ohta, Yasuo [Tsukuba Univ., Sakura, Ibaraki (Japan)

    1982-03-01

    The mechanisms causing male sterility in higher plants were classified into two major categories: genetic and non-genetic. The former was further divided into six classes: 1) Anomality in spindle mechanism during meiosis, 2) chromosomal anomality such as haploidy, polyploidy, aneuploidy, chromosome some deficiency, inversion and reciprocal translocation, 3) presence of male sterile genes, 4) cytoplasmic abnormality, 5) the combination of some specific cytoplasm with particular genes, and 6) infections of microorganisms or viruses. Each mechanism was briefly explained, and the methods for the maintenance of parent lines for heterosis breeding and hybrid seed production were described. The non-genetic male sterility was classified into four types, which are caused by 1) low or high temperature, 2) water deficiency, 3) application of chemicals, and 4) radiation, with a brief explanation given for each of them.

  13. Do women's attitudes towards abortion and contraceptive methods influence their option for sterilization?

    Directory of Open Access Journals (Sweden)

    Elisabeth Meloni Vieira

    Full Text Available This paper analyzes the attitudes of low-income women towards abortion and contraception. A survey was conducted in 1992 with a total of 3,149 childbearing-age women living on the outskirts of the Greater Metropolitan São Paulo Area. The study focuses on a sub-sample of 583 women. Attitudes of sterilized and non-sterilized women are compared. Women, especially those sterilized, found the most important attribute of a contraceptive method to be its effectiveness. Women currently taking the pill were less likely than those sterilized to agree that sterilization was the best method because of its effectiveness. Sterilized women were less likely than non-sterilized women to trust the pill. Sterilized women were more likely than non-sterilized to have reported adverse effects from the pill. Most women found abortion unacceptable except in the case of risk to the woman's life. Women using more effective methods showed stronger negative attitudes towards abortion. The tendency to be sterilized while still young was associated with more negative attitudes towards abortion. Family planning activities in basic health care services should include individual counseling for contraceptive use.

  14. Do women's attitudes towards abortion and contraceptive methods influence their option for sterilization?

    Directory of Open Access Journals (Sweden)

    Vieira Elisabeth Meloni

    1999-01-01

    Full Text Available This paper analyzes the attitudes of low-income women towards abortion and contraception. A survey was conducted in 1992 with a total of 3,149 childbearing-age women living on the outskirts of the Greater Metropolitan São Paulo Area. The study focuses on a sub-sample of 583 women. Attitudes of sterilized and non-sterilized women are compared. Women, especially those sterilized, found the most important attribute of a contraceptive method to be its effectiveness. Women currently taking the pill were less likely than those sterilized to agree that sterilization was the best method because of its effectiveness. Sterilized women were less likely than non-sterilized women to trust the pill. Sterilized women were more likely than non-sterilized to have reported adverse effects from the pill. Most women found abortion unacceptable except in the case of risk to the woman's life. Women using more effective methods showed stronger negative attitudes towards abortion. The tendency to be sterilized while still young was associated with more negative attitudes towards abortion. Family planning activities in basic health care services should include individual counseling for contraceptive use.

  15. Identification of dominant male sterile mutants in rice (Oryza sativa L.)

    International Nuclear Information System (INIS)

    Zhu Xudong; Rutger, J.N.

    2000-01-01

    Genetic male sterile mutants 1783 and 1789 were selected from US variety Orion and Kaybonnet seeds treated by gamma irradiation. Investigation of fertility characterization of pollen and spikelets of these mutants were made by progeny tests in 1783 M 7 and 1789 M 6 generations. The results showed that genetic male sterile mutants 1783 and 1789 with the fertility segregating of 1 sterile: 1 fertile were controlled by a single dominant gene. The pollen staining of mutants characterized partial sterility. Open-pollinated seed set was about 30% and bagged seed set was only 0.3%-3.5%. It is concluded that dominant genetic male sterile is a useful tool in improvement of population for rice breeding

  16. Comparative evaluation of four different sterilization methods on contaminated endodontic files

    Directory of Open Access Journals (Sweden)

    Malathi Yenni

    2017-01-01

    Full Text Available Background: The reuse of instruments in the field of endodontics leads to cross infection due to contamination with microbes as the instruments come into direct contact with saliva, blood, and infected tissues. Since microbes are considered to be the major cause of endodontic failures, sterilization of endodontic instruments is mandatory for maintaining asepsis to prevent cross-contamination from one person to other. Hence, the present study was conducted to compare the effectiveness of four different methods of sterilizing contaminated endodontic files. Materials and Methods: A total of 48 stainless steel K files were divided into four groups based on the sterilization method followed – Group A: Autoclave, Group B: Glass bead sterilization, Group C: Glutaraldehyde, and Group D: Quitanet Plus (aldehyde-free solution. In all the tested groups, half of the files were contaminated with Escherichia coli and remaining with Enterococcus faecalis. Then, presterilization colony counts were recorded, followed by sterilization through respective methods. Later, the sterilized files were rinsed with distilled water and 100 ul of the diluted concentration was transferred and cultured onto the respective agar plates to determine the total microbial reduction. Results: Autoclave showed complete effectiveness in reducing the microbial count followed by Quitanet Plus, glass bead sterilizer, and glutaraldehyde. Conclusion: Autoclave is considered to be the best sterilization technique to prevent cross infection in endodontic therapy.

  17. Pressure-assisted thermal sterilization of soup

    Science.gov (United States)

    Shibeshi, Kidane; Farid, Mohammed M.

    2010-12-01

    The overall efficiency of an existing scale-up pressure-assisted thermal sterilization (PATS) unit was investigated with regards to inactivation of Geobacillus stearothermophilus spores suspended in pumpkin soup. The PATS unit is a double pipe heat exchanger in which the soup is pumped into its inner high pressure tube and constrained by two high pressure valves, while steam is continuously passed through the annular region to heat the content. The technology is based on pressure generation by thermal expansion of the liquid in an enclosure. In this work, the addition of an air line to push the treated liquid food out of the existing PATS unit has improved the overall quality of the treated samples, as evidenced by achieving higher log reduction of the spores. Compared with thermal processing, the application of PATS shows the potential for lowering the thermal treatment temperature, offering improved food quality.

  18. Sterile insect technique: new technology to control fruit flies, Ceratitis capitata, in the Lower Basin of the Sao Francisco Valley

    International Nuclear Information System (INIS)

    Paranhos, Beatriz Aguiar Jordao; Barbosa, Flavia Rabelo; Nascimento, Antonio Souza do; Viana, Rodrigo; Malavasi, Aldo; Sampaio, Raimundo; Walder, Julio Marcos Melges

    2008-01-01

    The SIT is the creation, on a large scale, the insect-pest to be controlled and weekly release of these insects sterilized in the field.The sterile insects copulate with the wild, but do not generate descendants. The basic premises for the use of SIT in insect control are: the reproduction is through sexual intercourse, the female copulate preferably only once there is ease of creation of the plague in industrial scale in artificial diet. The efficiency of the SIT may be greater when only the males are released in the field because they increase the probability of copulating with wild females only, with reductions in the cost of production and release. In the case of fruit-flies, sterile females continue doing puncture in the fruits, which decreases the quality for export. To be able to release only males in the field, in 1980s, was developed a mutant strain, whose females emerge from pupae white, thus being able to discard the white ones, keeping the pupae Brown for the release of sterile males. Ten years after, to save on the industrial scale production system, was obtained a mutant whose females possess lethal temperature sensitivity of 34 deg C, still in the embryo stage. Then the eggs are placed on artificial diet, and when they arrive at the pupa stage, they are all brown and males. Forty-eight to 24 hours before the emergence of adults, the pupae are painted with fluorescent powder paint, bagged and irradiated with gamma radiation of 95Gy of Co-60 or X-ray. As soon as the males emerge, are marked with fluorescent ink and when they reach 3 to 5 days old, are released into the field. Thus, when monitoring is done in Jackson traps in the field, it is possible to distinguish wild male sterile under black light or epifluorescence microscope with males, because the sterile are fluorescent. On application of the SIT to Moscamed, sterile males are released in the field must display good dispersibility, good survival and good sexual performance. The efficiency and

  19. Gamma-irradiation sterilization of lipases for cheese making

    Energy Technology Data Exchange (ETDEWEB)

    Umanskij, M S; Borovkova, Yu A; Odegov, N I [Vsesoyuznyj Nauchno-Issledovatel' skij Inst. Maslodel' noj i Syrodel' noj Promyshlennosti, Uglich (USSR)

    1979-03-01

    The possibility of sterilizing the enzyme compounds of lipases from Oospora fragrans strains by gamma irradiation was studied. The enzyme compounds were exposed to gamma irradiation at the doses from 0.1 to 0.8 Mrad with the discreteness of 0.1 Mrad and at the dose of 2.0 Mrad. After the radiation treatment the lipases were investigated for bacterial invasion by the cultivation method and for the lipolytic activity by the titrometrical method. It is shown that the sterilization effect is achieved without losses of lipase activity and the radiation dose necessary for sterilization depends on initial invasion levels in the enzyme compounds.

  20. Sterile Neutrino Search with the Double Chooz Experiment

    Science.gov (United States)

    Hellwig, D.; Matsubara, T.; Double Chooz Collaboration

    2017-09-01

    Double Chooz is a reactor antineutrino disappearance experiment located in Chooz, France. A far detector at a distance of about 1 km from reactor cores is operating since 2011; a near detector of identical design at a distance of about 400 m is operating since begin 2015. Beyond the precise measurement of θ 13, Double Chooz has a strong sensitivity to so called light sterile neutrinos. Sterile neutrinos are neutrino mass states not taking part in weak interactions, but may mix with known neutrino states. In this paper, we present an analysis method to search for sterile neutrinos and the expected sensitivity with the baselines of our detectors.

  1. Processing laboratory of radio sterilized biological tissues

    International Nuclear Information System (INIS)

    Aguirre H, Paulina; Zarate S, Herman; Silva R, Samy; Hitschfeld, Mario

    2005-01-01

    The nuclear development applications have also reached those areas related to health. The risk of getting contagious illnesses through applying biological tissues has been one of the paramount worries to be solved since infectious illnesses might be provoked by virus, fungis or bacterias coming from donors or whether they have been introduced by means of intermediate stages before the use of these tissues. Therefore it has been concluded that the tissue allografts must be sterilized. The sterilization of medical products has been one of the main applications of the ionizing radiations and that it is why the International Organization of Atomic Energy began in the 70s promoting works related to the biological tissue sterilization and pharmaceutical products. The development of different tissue preservation methods has made possible the creation of tissue banks in different countries, to deal with long-term preservation. In our country, a project was launched in 1998, 'Establishment of a Tissue Bank in Latino america', this project was supported by the OIEA through the project INT/ 6/ 049, and was the starting of the actual Processing Laboratory of Radioesterilized Biological Tissues (LPTR), leaded by the Chilean Nuclear Energy Commission (CCHEN). This first organization is part of a number of entities compounding the Tissue Bank in Chile, organizations such as the Transplantation Promotion Corporation hospitals and the LPTR. The working system is carried out by means of the interaction between the hospitals and the laboratory. The medical professionals perform the procuring of tissues in the hospitals, then send them to the LPTR where they are processed and sterilized with ionizing radiation. The cycle ends up with the tissues return released to the hospitals, where they are used, and then the result information is sent to the LPTR as a form of feedback. Up to now, human skin has been processed (64 donors), amniotic membranes (35 donors) and pig skin (175 portions

  2. Translocation-based genetic sexing system to enhance the sterile insect technique against the melon fly (Diptera: Tephritidae)

    International Nuclear Information System (INIS)

    McCombs, S.D.; Lee, S.G.; Saul, S.H.

    1993-01-01

    The autosomal recessive bubble wing (bw) mutant was used to construct a translocation-based genetic sex sorting system in the melon fly, Bactrocera cucurbitae (Coquillett). The translocation stock has females with the bubble wing phenotype that are unable to fly, but the males are wild-type and fly normally. The bubble wing translocation strain has lower egg hatch, larval viability, and eclosion rates than the wild-type strain. Expression of the bubble wing trait is temperature-dependent, with high expression of the trait in 92% of adults at 23°C but in only 15% of adults at 28°C. This translocation-based sex sorting system is the only method available for automatic separation of male and female melon flies in sterile insect release programs

  3. Process variation in electron beam sterilization

    International Nuclear Information System (INIS)

    Beck, Jeffrey A.

    2012-01-01

    The qualification and control of electron beam sterilization can be improved by the application of proven statistical analysis techniques such as Analysis of Variance (ANOVA) and Statistical Tolerance Limits. These statistical techniques can be useful tools in: •Locating and quantifying the minimum and maximum absorbed dose in a product. •Estimating the expected process maximum dose, given a minimum sterilizing dose. •Setting a process minimum dose target, based on an allowance for random measurement and process variation. •Determining the dose relationship between a reference dosimeter and process minimum and maximum doses. This study investigates and demonstrates the application of these tools in qualifying electron beam sterilization, and compares the conclusions obtained with those obtained using practices recommended in Guide for Process Control in Radiation Sterilization. The study supports the following conclusions for electron beam processes: 1.ANOVA is a more effective tool for evaluating the equivalency of absorbed doses than methods suggested in . 2.Process limits computed using statistical tolerance limits more accurately reflect actual process variability than the AAMI method, which applies +/−2 sample standard deviations (s) regardless of sample size. 3.The use of reference dose ratios lends itself to qualification using statistical tolerance limits. The current AAMI recommended approach may result in an overly optimistic estimate of the reference dose adjustment factor, as it is based on application of +/−2(s) tolerances regardless of sample size.

  4. A White Paper on keV sterile neutrino Dark Matter

    Energy Technology Data Exchange (ETDEWEB)

    Adhikari, R. [Centre for Theoretical Physics, Jamia Millia Islamia (Central University), New Delhi-110025 (India); Agostini, M. [Gran Sasso Science Institute (INFN), L' Aquila (Italy); Ky, N. Anh [Institute of physics, Vietnam academy of science and technology, 10 Dao Tan, Ba Dinh, Hanoi (Viet Nam); Araki, T. [Department of physics, Saitama University, Shimo-Okubo 255, 338-8570 Saitama Sakura-ku (Japan); Archidiacono, M. [Department of Physics and Astronomy, University of Aarhus, DK-8000 Aarhus C (Denmark); Bahr, M. [University of California, Santa Barbara (United States); Baur, J. [Commissariat à l' énergie atomique et aux énergies alternatives, Centre de Saclay, DSM/IRFU, 91191 Gif-sur-Yvette (France); Behrens, J. [Westfälische Wilhelms Universität Münster, Institut für Kernphysik, Wilhelm Klemm-Str.9, D-48149 Münster (Germany); Bezrukov, F. [University of Connecticut (United States); Dev, P.S. Bhupal [Consortium for Fundamental Physics, School of Physics and Astronomy, University of Manchester, Manchester M13 9PL (United Kingdom); Borah, D. [Department of Physics, Indian Institute of Technology Guwahati, Assam-781039 (India); Boyarsky, A. [Universiteit Leiden - Instituut Lorentz for Theoretical Physics, P.O. Box 9506, NL-2300 RA Leiden, Netherlands (Netherlands); De Gouvea, A. [Northwestern University (United States); Pires, C.A. de S. [Departamento de Física, UFPB, Caixa Postal 5008, 58051-970, João Pessoa, PB (Brazil); De Vega, H.J. [CNRS LPTHE UPMC Univ P. et M. Curie Paris VI (France); and others

    2017-01-01

    We present a comprehensive review of keV-scale sterile neutrino Dark Matter, collecting views and insights from all disciplines involved—cosmology, astrophysics, nuclear, and particle physics—in each case viewed from both theoretical and experimental/observational perspectives. After reviewing the role of active neutrinos in particle physics, astrophysics, and cosmology, we focus on sterile neutrinos in the context of the Dark Matter puzzle. Here, we first review the physics motivation for sterile neutrino Dark Matter, based on challenges and tensions in purely cold Dark Matter scenarios. We then round out the discussion by critically summarizing all known constraints on sterile neutrino Dark Matter arising from astrophysical observations, laboratory experiments, and theoretical considerations. In this context, we provide a balanced discourse on the possibly positive signal from X-ray observations. Another focus of the paper concerns the construction of particle physics models, aiming to explain how sterile neutrinos of keV-scale masses could arise in concrete settings beyond the Standard Model of elementary particle physics. The paper ends with an extensive review of current and future astrophysical and laboratory searches, highlighting new ideas and their experimental challenges, as well as future perspectives for the discovery of sterile neutrinos.

  5. A search for sterile neutrinos with the latest cosmological observations

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Lu; Zhang, Jing-Fei [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Zhang, Xin [Northeastern University, Department of Physics, College of Sciences, Shenyang (China); Peking University, Center for High Energy Physics, Beijing (China)

    2017-06-15

    We report the result of a search for sterile neutrinos with the latest cosmological observations. Both cases of massless and massive sterile neutrinos are considered in the ΛCDM cosmology. The cosmological observations used in this work include the Planck 2015 temperature and polarization data, the baryon acoustic oscillation data, the Hubble constant direct measurement data, the Planck Sunyaev-Zeldovich cluster counts data, the Planck lensing data, and the cosmic shear data. We find that the current observational data give a hint of the existence of massless sterile neutrino (as dark radiation) at the 1.44σ level, and the consideration of an extra massless sterile neutrino can indeed relieve the tension between observations and improve the cosmological fit. For the case of massive sterile neutrino, the observations give a rather tight upper limit on the mass, which implies that actually a massless sterile neutrino is more favored. Our result is consistent with the recent result of neutrino oscillation experiment done by the Daya Bay and MINOS collaborations, as well as the recent result of cosmic ray experiment done by the IceCube collaboration. (orig.)

  6. Sterilizing elastomeric chains without losing mechanical properties. Is it possible?

    Directory of Open Access Journals (Sweden)

    Matheus Melo Pithon

    2015-06-01

    Full Text Available OBJECTIVE: To investigate the effects of different sterilization/disinfection methods on the mechanical properties of orthodontic elastomeric chains. METHODS: Segments of elastomeric chains with 5 links each were sent for sterilization by cobalt 60 (Co60 (20 KGy gamma ray technology. After the procedure, the elastomeric chains were contaminated with clinical samples of Streptococcus mutans. Subsequently, the elastomeric chains were submitted to sterilization/disinfection tests carried out by means of different methods, forming six study groups, as follows: Group 1 (control - without contamination, Group 2 (70°GL alcohol, Group 3 (autoclave, Group 4 (ultraviolet, Group 5 (peracetic acid and Group 6 (glutaraldehyde. After sterilization/disinfection, the effectiveness of these methods, by Colony forming units per mL (CFU/mL, and the mechanical properties of the material were assessed. Student's t-test was used to assess the number of CFUs while ANOVA and Tukey's test were used to assess elastic strength. RESULTS: Ultraviolet treatment was not completely effective for sterilization. No loss of mechanical properties occurred with the use of the different sterilization methods (p > 0.05. CONCLUSION: Biological control of elastomeric chains does not affect their mechanical properties.

  7. Genetic architecture of autosome-mediated hybrid male sterility in Drosophila.

    Science.gov (United States)

    Marín, I

    1996-04-01

    Several estimators have been developed for assessing the number of sterility factors in a chromosome based on the sizes of fertile and sterile introgressed fragments. Assuming that two factors are required for producing sterility, simulations show that one of these, twice the inverse of the relative size of the largest fertile fragment, provides good average approximations when as few as five fertile fragments are analyzed. The estimators have been used for deducing the number of factors from previous data on several pairs of species. A particular result contrasts with the authors' interpretations: instead of the high number of sterility factors suggested, only a few per autosome are estimated in both reciprocal crosses involving Drosophila buzzatii and D. koepferae. It has been possible to map these factors, between three and six per chromosome, in the autosomes 3 and 4 of these species. Out of 203 introgressions of different fragments or combinations of fragments, the outcome of at least 192 is explained by the mapped zones. These results suggest that autosome-mediated sterility in the male hybrids of these species is mediated by a few epistatic factors, similarly to X-mediated sterility in the hybrids of other Drosophila species.

  8. Sterilization of DACUS CUCUMIS FRENCH (DIPTERA:TEPHRITIDAE) by gamma radiation

    International Nuclear Information System (INIS)

    Hooper, G.H.S.

    1975-01-01

    The effect of gamma radiation administered to newly emerged adults of Dacus cucumis French on sterility and competitiveness was evaluated. A dose of 11 krad caused almost complete sterility in males while females given 6 krad were totally sterile, through infecundity. Sterilized males showed reduced competitiveness. In competitive mating tests a dose of 7 krad gave the lowest egg hatch and this hatch was significantly lower than that given by 9 and 11 krad. In a paired comparison mating test, 7 and 9 krad treated males mated significantly less frequently than untreated males, but the ability of 6 krad treated males was unimpared. (author)

  9. Male sterility in chestnuts. A tentative plan for the seed propagation of fruit trees

    Energy Technology Data Exchange (ETDEWEB)

    Omura, Mitsuo; Akihama, Tomoya [Fruit Tree Research Station, Yatabe, Ibaraki (Japan)

    1982-03-01

    A tentative plan was proposed for chestnuts based on their pollination system, male sterility and restoration. The studies on the male sterility of 1,063 cultivars and clones suggested that there were three types of male sterility. The first type (S-1) was characterized by antherless florets. In the second type (S-2), the catkins fell before anthesis, and the third type (S-3) appeared to develop normally in gross floral morphology, but the pollen grains were abnormal in shape and did not have germinating power. In an interspecific hybrid clone CS which belonged to S-1, fertility was restored in an open pollinated progeny. The use of CS and CSO-3 with its restored fertility, permitted the planning of breeding the chestnut hybrid cultivars propagated by seeds. The inbred clones with either male sterility or restorer genes are first bred mainly by back crossing with parents with favorable pollen. The clones are selected individually for early bearing, wasp and disease resistance, and restoration. Then, the hybrid seedling lines between male sterile and restorer inbreds are evaluated for homogenity in nut characters and tree habits. Next, the hybrid seedling lines selected will be examined for crop yield, vigor and cross compatibility. The superior seedling lines are finally selected, and the parental inbreds are grafted to be propagated for seed production orchards.

  10. Sterilization of allograft bone: is 25 kGy the gold standard for gamma irradiation?

    Science.gov (United States)

    Nguyen, Huynh; Morgan, David A F; Forwood, Mark R

    2007-01-01

    For several decades, a dose of 25 kGy of gamma irradiation has been recommended for terminal sterilization of medical products, including bone allografts. Practically, the application of a given gamma dose varies from tissue bank to tissue bank. While many banks use 25 kGy, some have adopted a higher dose, while some choose lower doses, and others do not use irradiation for terminal sterilization. A revolution in quality control in the tissue banking industry has occurred in line with development of quality assurance standards. These have resulted in significant reductions in the risk of contamination by microorganisms of final graft products. In light of these developments, there is sufficient rationale to re-establish a new standard dose, sufficient enough to sterilize allograft bone, while minimizing the adverse effects of gamma radiation on tissue properties. Using valid modifications, several authors have applied ISO standards to establish a radiation dose for bone allografts that is specific to systems employed in bone banking. These standards, and their verification, suggest that the actual dose could be significantly reduced from 25 kGy, while maintaining a valid sterility assurance level (SAL) of 10(-6). The current paper reviews the methods that have been used to develop radiation doses for terminal sterilization of medical products, and the current trend for selection of a specific dose for tissue banks.

  11. Supercritical Carbon Dioxide–Based Sterilization of Decellularized Heart Valves

    Directory of Open Access Journals (Sweden)

    Ryan S. Hennessy, MD

    2017-02-01

    Full Text Available Summary: Sterilization of grafts is essential. Supercritical carbon dioxide, electrolyzed water, gamma radiation, ethanol-peracetic acid, and hydrogen peroxide techniques were compared for impact on sterility and mechanical integrity of porcine decellularized aortic valves. Ethanol-peracetic acid– and supercritical carbon dioxide–treated valves were found to be sterile using histology, microbe culture, and electron microscopy assays. The cusp tensile properties of supercritical carbon dioxide–treated valves were higher compared with valves treated with other techniques. Superior sterility and integrity was found in the decellularized valves treated with supercritical carbon dioxide sterilization. This sterilization technique may hold promise for other decellularized soft tissues. Key Words: decellularized, decontamination, heart valve, tensile properties, tissue engineering

  12. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    International Nuclear Information System (INIS)

    Huang, Junting

    2015-01-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states v e , v μ and v τ . In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ 24 in the range of 10 -2 eV 2 < Δm 43 2 < 1 eV 2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  13. Benchmarking of Sterilizing grade filters with liposome Filtration.

    Science.gov (United States)

    Loewe, Thomas; Mundlamuri, Ramesh; Loewe, Thomas; Mundrigi, Ashok; Handt, Sebastian; Singh, Bhuwan

    2017-12-14

    Cytotoxic drugs can be encapsulated in liposomes vesicles, which act as drug delivery vehicles and reduce the risk of exposure of drug to healthy cells(1). The sterility of such liposome solutions is typically ensured using 0.2μm rated sterilizing grade membranes, but due to the high viscosity and low surface tension of these formulations, they can cause pre-mature blocking and increased risk of bacterial penetration through a 0.2μm sterilizing grade membrane(2). The low surface tension of liposome solutions affects the contact angle with membrane and reduces bubble point leading to bacterial penetration through the membrane. This poses a great challenge to select an appropriate sterilizing grade membrane for a given process and for filter manufacturers to develop a sterilizing grade membrane that specifically addresses these needs. In this study, the influence of different variables that could affect the total throughput and bacterial retention performance of different membranes types on processing of liposome solutions have been evaluated. Based on the results, we conclude that the membrane properties e.g., surface porosity, surface tension, pore size, symmetry/asymmetry, hydrophilicity and liposome properties e.g., composition, lipid size and concentration affect bacterial retention and total throughput capacity. Process parameters such as temperature, pressure and flow should also be optimized to improve process efficiency. Copyright © 2017, Parenteral Drug Association.

  14. Radiation sterilization of potato starch and Sedonik

    International Nuclear Information System (INIS)

    Tashmetov, M.Yu.; Ismatov, N.B.; Saidov, R.P. et al.

    2016-01-01

    The raw material of pharmaceutical preparations potato starch and sedative means of Sedonik are sterilized at the electron's accelerator Electronics U-003. It is established that at 20.3 kGy absorbed dose and electron's energy 3 - 5 MeV the results of microbiological analysis showed sterility of potato starch and Sedonik and correspondence of their physical-optical properties to the requirements of normative documents. (authors)

  15. Mass-rearing for sterile insect release

    International Nuclear Information System (INIS)

    Parker, A.G.

    2005-01-01

    As the sterile insect technique (SIT) relies upon released sterile male insects efficiently competing with wild males to mate with wild females, it follows that mass-rearing of insects is one of the principal steps in the process. Mass-rearing for the SIT presents both problems and opportunities due to the increased scale involved compared with rearing insects for most other purposes. This chapter discusses facility design, environmental concerns, strain management, quality control, automation, diet, sex separation, marking, and storage in relation to rearing for the SIT. (author)

  16. Multilevel Perspectives on Female Sterilization in Low-Income Communities in Mumbai, India.

    Science.gov (United States)

    Brault, Marie A; Schensul, Stephen L; Singh, Rajendra; Verma, Ravi K; Jadhav, Kalpita

    2016-09-01

    Surgical sterilization is the primary method of contraception among low-income women in India. This article, using qualitative analysis of key informant, in-depth interviews, and quantitative analyses, examines the antecedents, process, and outcomes of sterilization for women in a low-income area in Mumbai, India. Family planning policies, socioeconomic factors, and gender roles constrain women's reproductive choices. Procedures for sterilization rarely follow protocol, particularly during pre-procedure counseling and consent. Women who choose sterilization often marry early, begin conceiving soon after marriage, and reach or exceed ideal family size early due to problems in accessing reversible contraceptives. Despite these constraints, this study indicates that from the perspective of women, the decision to undergo sterilization is empowering, as they have fulfilled their reproductive duties and can effectively exercise control over their fertility and sexuality. This empowerment results in little post-sterilization regret, improved emotional health, and improved sexual relationships following sterilization. © The Author(s) 2015.

  17. [Mechanisms of urinary tract sterility maintenance].

    Science.gov (United States)

    Okrągła, Emilia; Szychowska, Katarzyna; Wolska, Lidia

    2014-06-02

    Physiologically, urine and the urinary tract are maintained sterile because of physical and chemical properties of urine and the innate immune system's action. The urinary tract is constantly exposed to the invasion of microorganisms from the exterior environment, also because of the anatomical placement of the urethra, in the vicinity of the rectum. Particularly vulnerable to urinary tract infections (UTI) are women (an additional risk factor is pregnancy), but also the elderly and children. The main pathogens causing UTI are bacteria; in 70-95% of cases it is the bacterium Escherichia coli. Infections caused by viruses and fungi are less common and are associated with decreased immunity, pharmacotherapy, or some diseases. Bacteria have evolved a number of factors that facilitate the colonization of the urinary tract: the cover and cell membrane antigens O and K1, lipopolysaccharide (LPS), fimbriae, pile and cilia. On the other hand, the human organism has evolved mechanisms to hinder colonization of the urinary tract: mechanisms arising from the anatomical structure of the urinary tract, the physicochemical properties of the urine and the activity of the innate immune system, also known as non-specific, which isolates and destroys pathogens using immunological processes, and the mechanisms for release of antimicrobial substances such as Tamm-Horsfall protein, mucopolysaccharides, immunoglobulins IgA and IgG, lactoferrin, lipocalin, neutrophils, cytokines and antimicrobial peptides. This review aims to analyze the state of knowledge on the mechanisms to maintain the sterility of the urinary tract used by the human organism and bacterial virulence factors to facilitate the colonization of the urinary tract.

  18. Introduction, maintenance and utilization of male sterility in leek (Allium ampeloprasum L.) = [Inductie, handhaving en gebruik van mannelijke steriliteit in prei (Allium ampeloprasum L.)

    NARCIS (Netherlands)

    Silvertand, B.

    1996-01-01


    This thesis describes research work performed in leek in relation to efforts to obtain or exploit a male sterility system for hybrid leek breeding. Male sterile plants can be found in every leek cultivar. The male sterility trait can be explained by a nuclear monogenic inheritance or by a

  19. Effect of sterilization on the properties of CDHA-OCP-beta-TCP biomaterial

    Directory of Open Access Journals (Sweden)

    Loreley Morejón-Alonso

    2007-03-01

    Full Text Available The effect of the method of sterilization on the physical, chemical and mechanical properties of a new bone repairing material was studied. The material was obtained by thermal hydrolysis of beta-tricalcium phosphate/orthophosphoric acid cement and was composed of calcium deficient hydroxyapatite, octacalcium phosphate (OCP, and beta-tricalcium phosphate. Partial decomposition of the OCP was observed after sterilization for the three methods. Decomposition increased to the following sequence of sterilization methods: ethylene oxide; autoclaving; dry oven. On the other hand, mechanical strength decreased with regard to non sterilized material in the sterilization sequence: ethylene oxide; dry oven; autoclaving. The compressive strength was 8.5 ± 1.0; 9.0 ± 1.2; 8.2 ± 0.8 and 6.5 ± 1.0 MPa, whereas diametral tensile strength was 2.1 ± 0.3; 2.5 ± 0.1; 1.9 ± 0.9 and 1.6 ± 0.3 for the material sterilized by ethylene oxide, dry oven, and autoclaving, respectively. Several compositional and microstuctural changes were detected after dry heat and autoclave sterilization. Ethylene oxide sterilization had lesser effect on the chemical composition and strength than dry heat and autoclaving.

  20. Laparoscopic tubal sterilization reversal and fertility outcomes

    Directory of Open Access Journals (Sweden)

    K Jayakrishnan

    2011-01-01

    Full Text Available Purpose: The purpose of the study was two-fold. Firstly it was to assess the suitability for tubal recanalization and factors predicting successful laparoscopic recanalization. Secondly, it was to analyze the fertility outcomes and factors affecting the pregnancy rate following laparoscopic tubal recanalization. Materials and Methods: A retrospective chart review of prospectively followed-up 29 women at a tertiary care center seeking tubal sterilization reversal between May 2005 and February 2010 were included. Results: In 14 (48.3% women unilateral tubes were suitable and in only 3 women (10.3% bilateral tubes were suitable. All cases with laparoscopic tubal sterilization were suitable, whereas all cases with fimbriectomy were unsuitable for recanalization. In 6 (20.7% cases salphingostomy was performed as an alternative procedure to tubal reanastomosis. The overall pregnancy rate was 58.8%. In cases with sterilization by Pomeroy′s method, 4 out of 10 (40% conceived, whereas for laparoscopic tubal ligation cases 6 out of 7 (85.7% conceived (P=0.32. None of the patients with final tubal length <5 cm conceived (P=0.03. Comparing the age at recanalization, in women ≤30 years, 71.4% conceived, as compared with 50% when age of women was more than 30 years (P=0.37. Conclusions: The important factors determining the success of recanalization are technique of sterilization and the remaining length of the tube after recanalization. The gynecologist must use an effective technique of sterilization to minimize the failure rates, but at the same time, which causes minimal trauma, and aim at preserving the length of the tube so that reversal is more likely to be successful, should the patient′s circumstances change.

  1. Sterilization of Microorganisms by Ozone and Ultrasound

    Science.gov (United States)

    Krasnyj, V. V.; Klosovskij, A. V.; Panasko, T. A.; Shvets, O. M.; Semenova, O. T.; Taran, V. S.; Tereshin, V. I.

    2008-03-01

    The results of recent experimental methods of sterilization of microorganisms with the use of ozone and ultrasound are presented. The main aim was to optimize the process of sterilization in water solution taking into account the ozone concentration, the power of ultrasonic emitter and the temperature of water. In the present work, the ultrasonic cavitation with simultaneous ozone generation has been used. The high ozone concentration in water solution was achieved by two-barrier glow discharge generated at atmospheric pressure and a cooling thermo-electric module. Such a sterilizer consists of ozone generator in a shape of flat electrodes covered with dielectric material and a high-voltage pulsed power supply of 250 W. The sterilization camera was equipped with ultrasonic source operated at 100 W. The experiments on the inactivation of bacteria of the Bacillus Cereus type were carried out in the distilled water saturated by ozone. The ozone concentration in the aqueous solution was 10 mg/1, whereas the ozone concentration at the output of ozone generator was 30 mg/1. The complete inactivation of spores took 15 min. Selection of the temperature of water, the ozone concentrations and ultrasonic power allowed to determine the time necessary for destroying the row of microorganisms.

  2. The influence of sterilization on nitrogen-included ultrananocrystalline diamond for biomedical applications

    International Nuclear Information System (INIS)

    Tong, Wei; Tran, Phong A.; Turnley, Ann M.; Aramesh, Morteza; Prawer, Steven; Brandt, Milan; Fox, Kate

    2016-01-01

    Diamond has shown great potential in different biomedical applications, but the effects of sterilization on its properties have not been investigated. Here, we studied the influence of five sterilization techniques (solvent cleaning, oxygen plasma, UV irradiation, autoclave and hydrogen peroxide) on nitrogen-included ultrananocrystalline diamond. The chemical modification of the diamond surface was evaluated using X-ray photoelectron spectroscopy and water contact angle measurements. Different degrees of surface oxidation and selective sp 2 bonded carbon etching were found following all sterilization techniques, resulting in an increase of hydrophilicity. Higher viabilities of in vitro mouse 3T3 fibroblasts and rat cortical neuron cells were observed on oxygen plasma, autoclave and hydrogen peroxide sterilized diamond, which correlated with their higher hydrophilicity. By examination of apatite formation in simulated body fluid, in vivo bioactivity was predicted to be best on those surfaces which have been oxygen plasma treated and lowest on those which have been exposed to UV irradiation. The charge injection properties were also altered by the sterilization process and there appears to be a correlation between these changes and the degree of oxygen termination of the surface. We find that the modification brought by autoclave, oxygen plasma and hydrogen peroxide were most consistent with the use of N-UNCD in biological applications as compared to samples sterilized by solvent cleaning or UV exposure or indeed non-sterilized. A two-step process of sterilization by hydrogen peroxide following oxygen plasma treatment was then suggested. However, the final choice of sterilization technique will depend on the intended end application. - Highlights: • We test for the first time the effect of 5 sterilization techniques on nitrogen included ultrananocrystalline diamond. • Different degrees of surface oxidation and selective sp 2 bonded carbon etching were found to

  3. The influence of sterilization on nitrogen-included ultrananocrystalline diamond for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Tong, Wei [School of Physics, University of Melbourne, Parkville, Victoria (Australia); Tran, Phong A. [Department of Chemical and Biomolecular Engineering, University of Melbourne, Parkville, Victoria (Australia); Institute of Health and Biomedical Innovation, Queensland University of Technology, Kelvin Grove, Queensland (Australia); Turnley, Ann M. [Department of Anatomy and Neuroscience, University of Melbourne, Parkville, Victoria (Australia); Aramesh, Morteza [School of Physics, University of Melbourne, Parkville, Victoria (Australia); School of Chemistry, Physics, and Mechanical Engineering, Queensland University of Technology, Brisbane, Queensland (Australia); Prawer, Steven [School of Physics, University of Melbourne, Parkville, Victoria (Australia); Brandt, Milan [Centre for Additive Manufacturing, School of Aerospace, Mechanical and Manufacturing Engineering, RMIT University, Melbourne, Victoria (Australia); Fox, Kate, E-mail: kate.fox@rmit.edu.au [Centre for Additive Manufacturing, School of Aerospace, Mechanical and Manufacturing Engineering, RMIT University, Melbourne, Victoria (Australia)

    2016-04-01

    Diamond has shown great potential in different biomedical applications, but the effects of sterilization on its properties have not been investigated. Here, we studied the influence of five sterilization techniques (solvent cleaning, oxygen plasma, UV irradiation, autoclave and hydrogen peroxide) on nitrogen-included ultrananocrystalline diamond. The chemical modification of the diamond surface was evaluated using X-ray photoelectron spectroscopy and water contact angle measurements. Different degrees of surface oxidation and selective sp{sup 2} bonded carbon etching were found following all sterilization techniques, resulting in an increase of hydrophilicity. Higher viabilities of in vitro mouse 3T3 fibroblasts and rat cortical neuron cells were observed on oxygen plasma, autoclave and hydrogen peroxide sterilized diamond, which correlated with their higher hydrophilicity. By examination of apatite formation in simulated body fluid, in vivo bioactivity was predicted to be best on those surfaces which have been oxygen plasma treated and lowest on those which have been exposed to UV irradiation. The charge injection properties were also altered by the sterilization process and there appears to be a correlation between these changes and the degree of oxygen termination of the surface. We find that the modification brought by autoclave, oxygen plasma and hydrogen peroxide were most consistent with the use of N-UNCD in biological applications as compared to samples sterilized by solvent cleaning or UV exposure or indeed non-sterilized. A two-step process of sterilization by hydrogen peroxide following oxygen plasma treatment was then suggested. However, the final choice of sterilization technique will depend on the intended end application. - Highlights: • We test for the first time the effect of 5 sterilization techniques on nitrogen included ultrananocrystalline diamond. • Different degrees of surface oxidation and selective sp{sup 2} bonded carbon etching were

  4. Mechanisms of male sterility in higher plants

    International Nuclear Information System (INIS)

    Ohta, Yasuo

    1982-01-01

    The mechanisms causing male sterility in higher plants were classified into two major categories: genetic and non-genetic. The former was further divided into six classes: 1) Anomality in spindle mechanism during meiosis, 2) chromosomal anomality such as haploidy, polyploidy, aneuploidy, chromosome some deficiency, inversion and reciprocal translocation, 3) presence of male sterile genes, 4) cytoplasmic abnormality, 5) the combination of some specific cytoplasm with particular genes, and 6) infections of microorganisms or viruses. Each mechanism was briefly explained, and the methods for the maintenance of parent lines for heterosis breeding and hybrid seed production were described. The non-genetic male sterility was classified into four types, which are caused by 1) low or high temperature, 2) water deficiency, 3) application of chemicals, and 4) radiation, with a brief explanation given for each of them. (Kaihara, S.)

  5. Formation and release of non-extractable 14C-Dicamba residues in soil under sterile and non-sterile regimes

    International Nuclear Information System (INIS)

    Gevao, Bondi; Jones, Kevin C.; Semple, Kirk T.

    2005-01-01

    The role of native soil microorganisms in the formation and release of non-extractable 14 C-residues, previously treated with 14 C-Dicamba, was investigated to examine their significance to the longer-term environmental effects on non-extractable pesticide residues. A 90 d study compared the fate of Dicamba under sterile and non-sterile regimes. In addition, soils were aged for 30 d and repeatedly extracted with a 0.01 M CaCl 2 solution, to an extraction end point, to produce non-extractable residues. The extracted soil containing non-extractable residues was mixed with clean soil that had been freshly spiked with non-labeled Dicamba at 0.2 mg kg -1 to increase the bulk volume of the soil and stimulate microbial activity. Sub-samples were then introduced into microcosms to compare the extent of microbially facilitated release and mineralisation with release rates in sterile microcosms. The results show that microorganisms play a significant role in the formation and release of non-extractable Dicamba residues. The release of 14 C-activity in sterile microcosms was linked to physical mixing of the extracted soil with field soil prior to the beginning of the incubations. The released 14 C-activity may be further mineralized, reincorporated into humus, or taken up by plants or other soil inhabiting biota

  6. Bacterial spores survive treatment with commercial sterilants and disinfectants.

    Science.gov (United States)

    Sagripanti, J L; Bonifacino, A

    1999-09-01

    This study compared the activity of commercial liquid sterilants and disinfectants on Bacillus subtilis spores deposited on three types of devices made of noncorrodible, corrodible, or polymeric material. Products like Renalin, Exspor, Wavicide-01, Cidexplus, and cupric ascorbate were tested under conditions specified for liquid sterilization. These products, at the shorter times indicated for disinfection, and popular disinfectants, like Clorox, Cavicide, and Lysol were also studied. Data obtained with a sensitive and quantitative test suggest that commercial liquid sterilants and disinfectants are less effective on contaminated surfaces than generally acknowledged.

  7. Delayed pulsar kicks from the emission of sterile neutrinos

    International Nuclear Information System (INIS)

    Kusenko, Alexander; Mandal, Bhabani Prasad; Mukherjee, Alok

    2008-01-01

    The observed velocities of pulsars suggest the possibility that sterile neutrinos with mass of several keV are emitted from a cooling neutron star. The same sterile neutrinos could constitute all or part of cosmological dark matter. The neutrino-driven kicks can exhibit delays depending on the mass and the mixing angle, which can be compared with the pulsar data. We discuss the allowed ranges of sterile neutrino parameters, consistent with the latest cosmological and x-ray bounds, which can explain the pulsar kicks for different delay times

  8. The processing technology of bread crumbs sterilization by irradiation

    International Nuclear Information System (INIS)

    Zhu Jiating; Li Zhengkui; Zhao Yongfu; Zhang Weidong; Jin Jie; Wu Lei; Wang Xinghai

    2003-01-01

    The processing technology of bread crumbs sterilization by irradiation was studied. The results demonstrated that dose heterogeneity had osculatory connection with pile height and turning, sterilization effect had positive correlation with the irradiation dose and negative correlation with colour. Compared with the CK, the content of crud protein, fat, carbohydrate, microelement and amino acid in irradiated bread crumbs had no obvious change. It is recommended that the range of best sterilization dose be 6-10 kGy and the shelf time of bread crumbs be extended to one year

  9. Comparative Transcriptomes Profiling of Photoperiod-sensitive Male Sterile Rice Nongken 58S During the Male Sterility Transition between Short-day and Long-day

    Directory of Open Access Journals (Sweden)

    Zhu Yingguo

    2011-09-01

    Full Text Available Abstract Background Photoperiod-sensitive genic male sterile (PGMS rice, Nongken 58S, was discovered in 1973. It has been widely used for the production of hybrid rice, and great achievements have been made in improving rice yields. However, the mechanism of the male sterility transition in PGMS rice remains to be determined. Results To investigate the transcriptome during the male sterility transition in PGMS rice, the transcriptome of Nongken 58S under short-day (SD and long-day (LD at the glume primordium differentiation and pistil/stamen primordium forming stages was compared. Seventy-three and 128 differentially expressed genes (DEGs were identified at the glume primordium differentiation and pistil/stamen primordium forming stages, respectively. Five and 22 genes were markedly up-regulated (≥ 5-fold, and two and five genes were considerably down-regulated (≥ 5-fold under SD during the male sterility transition. Gene ontology annotation and pathway analysis revealed that four biological processes and the circadian rhythms and the flowering pathways coordinately regulated the male sterility transition. Further quantitative PCR analysis demonstrated that the circadian rhythms of OsPRR1, OsPRR37, OsGI, Hd1, OsLHY and OsDof in leaves were obviously different between Nongken 58S and Nongken 58 under LD conditions. Moreover, both OsPRR37 and Hd1 in the inflorescence displayed differences between Nongken 58S and Nongken 58 under both LD and SD conditions. Conclusion The results presented here indicate that the transcriptome in Nongken 58S was significantly suppressed under LD conditions. Among these DEGs, the circadian rhythm and the flowering pathway were involved in the male sterility transition. Furthermore, these pathways were coordinately involved in the male sterility transition in PGMS rice.

  10. Studies of Sterile Irradiation Effects on the White-striped Fruit Fly

    International Nuclear Information System (INIS)

    Limohpasmanee, Wanitch; Tannarin, Thodsapol; Khongratarpon, Titima; Segsarnviriya, Suchada

    2011-06-01

    Full text: In general, sterile irradiation can affect vigor and mating competitiveness of the fruit flies. The objective of the experiments was to study the effects of sterile irradiation on the white-striped oriental fruit fly, Bactrocera dorsalis (Hendel), developed for sterile fly detection. A day before adult emergence, the pupae were irradiated at the dose of 90 Grays. No effects on adult emergence and flight ability were observed. However, it induced complete sterility in both sexes. Also, it decreased male mating competitiveness significantly, while increasing sexual competitiveness significantly

  11. Bilateral cornual abscess after endometrial ablation following Essure sterilization.

    NARCIS (Netherlands)

    Jansen, N.E.; Vleugels, M.P.; Kluivers, K.B.; Vierhout, M.E.

    2007-01-01

    Endometrial ablation is used extensively to treat dysfunctional bleeding. Since the introduction of Essure tubal sterilization, this permanent contraception method has been widely used. Both endometrial ablation and Essure sterilization are procedures reported to have only a few complications. We

  12. A spatial model with pulsed releases to compare strategies for the sterile insect technique applied to the mosquito Aedes aegypti.

    Science.gov (United States)

    Oléron Evans, Thomas P; Bishop, Steven R

    2014-08-01

    We present a simple mathematical model to replicate the key features of the sterile insect technique (SIT) for controlling pest species, with particular reference to the mosquito Aedes aegypti, the main vector of dengue fever. The model differs from the majority of those studied previously in that it is simultaneously spatially explicit and involves pulsed, rather than continuous, sterile insect releases. The spatially uniform equilibria of the model are identified and analysed. Simulations are performed to analyse the impact of varying the number of release sites, the interval between pulsed releases and the overall volume of sterile insect releases on the effectiveness of SIT programmes. Results show that, given a fixed volume of available sterile insects, increasing the number of release sites and the frequency of releases increases the effectiveness of SIT programmes. It is also observed that programmes may become completely ineffective if the interval between pulsed releases is greater that a certain threshold value and that, beyond a certain point, increasing the overall volume of sterile insects released does not improve the effectiveness of SIT. It is also noted that insect dispersal drives a rapid recolonisation of areas in which the species has been eradicated and we argue that understanding the density dependent mortality of released insects is necessary to develop efficient, cost-effective SIT programmes. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  13. Induced pollen sterility in petunia. Mode of inheritance and tapetal behavior

    International Nuclear Information System (INIS)

    Singh, I.S.

    1975-01-01

    A study was undertaken to investigate the characteristics of different mutants for induced pollen sterility in Petunia hybrida Hort. The F 1 hybrid zygotes (TL-h 1 #female# x Sf-la #male#) were exposed to a 0.2% solution of ethyl methane sulfonate and to 0.75kR of 60 Co gamma rays. Their seeds were sown and pollen sterile plants were observed in the M 1 . The pattern of inheritance in the F 2 and the backcrosses of some selected pollen sterile M 1 mutants showed that sterility mutations had been induced. Whether the mutations are recessive or dominant is not yet known, but it has been shown that they act through the sporophytic tissues. Morphological and cytological observations on four highly sterile M 1 plants showed a similar abnormal behavior of the tapetum. The tapetum of the pollen sterile anthers was thicker, more vacuolated and did persist until a later stage than those in fertile anthers. It is suggested that the persistence of the tapetum after a certain stage blocks the trophic process required for the development of the microspore into viable pollen, and the cause of pollen abortion is sporophytic even when no inheritance of the sterility is observed [fr

  14. Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: An in vitro study

    Directory of Open Access Journals (Sweden)

    Venkatasubramanian R

    2010-03-01

    Full Text Available Sterilization is the best method to counter the threats of microorganisms. The purpose of sterilization in the field of health care is to prevent the spread of infectious diseases. In dentistry, it primarily relates to processing reusable instruments to prevent cross-infection. The aim of this study was to investigate the efficacy of 4 methods of sterilizing endodontic instruments: Autoclaving, carbon dioxide laser sterilization, chemical sterilization (with glutaraldehyde and glass-bead sterilization. The endodontic file was sterilized by 4 different methods after contaminating it with bacillus stearothermophillus and then checked for sterility by incubating after putting it in test tubes containing thioglycollate medium. The study showed that the files sterilized by autoclave and lasers were completely sterile. Those sterilized by glass bead were 90% sterile and those with glutaraldehyde were 80% sterile. The study concluded that autoclave or laser could be used as a method of sterilization in clinical practice and in advanced clinics; laser can be used also as a chair side method of sterilization.

  15. 9. School of radiation sterilization and hygienization - Lectures

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9 School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  16. 9. School of radiation sterilization and hygienization - Presentations

    International Nuclear Information System (INIS)

    Zimek, Z.; Kaluska, I.; Gluszewski, W.

    2007-01-01

    During the 9. School of radiation sterilization and hygienization 23 lectures were presented. They were devoted to all aspects of sterilization and hygienization of food, medicinal articles and cosmetics using the ionisation radiation. It was destined to physicians, manufacturers and vendees of spices, pharmaceuticals and cosmetics, personnel of the sanitary-epidemiological stations and even for the art conservators

  17. Genetic architecture of hybrid male sterility in Drosophila: analysis of intraspecies variation for interspecies isolation.

    Science.gov (United States)

    Reed, Laura K; LaFlamme, Brooke A; Markow, Therese A

    2008-08-27

    The genetic basis of postzygotic isolation is a central puzzle in evolutionary biology. Evolutionary forces causing hybrid sterility or inviability act on the responsible genes while they still are polymorphic, thus we have to study these traits as they arise, before isolation is complete. Isofemale strains of D. mojavensis vary significantly in their production of sterile F(1) sons when females are crossed to D. arizonae males. We took advantage of the intraspecific polymorphism, in a novel design, to perform quantitative trait locus (QTL) mapping analyses directly on F(1) hybrid male sterility itself. We found that the genetic architecture of the polymorphism for hybrid male sterility (HMS) in the F(1) is complex, involving multiple QTL, epistasis, and cytoplasmic effects. The role of extensive intraspecific polymorphism, multiple QTL, and epistatic interactions in HMS in this young species pair shows that HMS is arising as a complex trait in this system. Directional selection alone would be unlikely to maintain polymorphism at multiple loci, thus we hypothesize that directional selection is unlikely to be the only evolutionary force influencing postzygotic isolation.

  18. Stability and inheritance of photoperiod-sensitive genic male sterility in rice

    International Nuclear Information System (INIS)

    Zhu, Y.G.; Yu, J.H.

    1990-01-01

    Full text: In 1973, a photoperiod-sensitive genic male-sterile plant was discovered in Nongken 58. It is male sterile under long day conditions and fertile under short day conditions. Under the natural photoperiod in Wuhan, plants heading before September 2 are male sterile, showing typical pollen abortion. The fertility is gradually restored after September 2. About 50% of pollen grains are normal after September 6. F 1 using 30 different varieties was fertile regardless of daylength, F 2 segregated into 3 fertile: 1 sterile types under long day condition in some crosses, less clearly in other crosses. It is concluded that photoperiod depending male sterility is monogenic recessive inherited with some influence of modifier genes. Any normal variety can be used as restorer, therefore strong heterosis combinations can easily be bred. (author)

  19. Improving the sterile sperm identification method for its implementation in the area-wide sterile insect technique program against Ceratitis capitata (Diptera: Tephritidae) in Spain

    International Nuclear Information System (INIS)

    Juan-Blasco, M.; Urbaneja, A.; San Andrés, V.; Sabater-Muñoz, B.; Castañera, P.

    2014-01-01

    The success of sterile males in area-wide sterile insect technique (aw-SIT) programs against Ceratitis capitata (Wiedemann) is currently measured by using indirect methods as the wild: sterile male ratio captured in monitoring traps. In the past decade, molecular techniques have been used to improve these methods. The development of a polymerase chain reaction-restriction fragment-length polymorphism- based method to identify the transfer of sterile sperm to wild females, the target of SIT, was considered a significant step in this direction. This method relies on identification of sperm by detecting the presence of Y chromosomes in spermathecae DNA extract complemented by the identification of the genetic origin of this sperm: Vienna-8 males or wild haplotype. However, the application of this protocol to aw-SIT programs is limited by handling time and personnel cost. The objective of this work was to obtain a high-throughput protocol to facilitate the routine measurement in a pest population of sterile sperm presence in wild females. The polymerase chain reactionrestriction fragment-length polymorphism markers previously developed were validated in Mediterranean fruit by samples collected from various locations worldwide. A laboratory protocol previously published was modified to allow for the analysis of more samples at the same time. Preservation methods and preservation times commonly used for Mediterranean fruit by female samples were assessed for their influence on the correct molecular detection of sterile sperm. This high-throughput methodology, as well as the results of sample management presented here, provide a robust, efficient, fast, and economical sterile sperm identification method ready to be used in all Mediterranean fruit by SIT programs. (author)

  20. Sterile Neutrino Searches in MINOS and MINOS+ Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Junting [Univ. of Texas, Austin, TX (United States)

    2015-05-01

    This dissertation presents the searches on sterile neutrinos using the data collected in MINOS+ Experiment from September 2013 to September 2014, and the full data set of MINOS Experiment collected from 2005 to 2012. Anomalies in short baseline experiments, such as LSND and MiniBooNE, showed hints of sterile neutrinos, a type of neutrino that does not interact with the Standard Model particles. In this work, two models are considered: 3+1 and large extra dimension (LED). In the 3+1 model, one sterile neutrino state is added into the standard oscillation scheme consisting of three known active neutrino states ve, vμ and vτ. In the LED model, sterile neutrinos arise as Kaluza-Klein (KK) states due to assumed large extra dimensions. Mixing between sterile and active neutrino states may modify the oscillation patterns observed in the MINOS detectors. Both searches yield null results. For 3+1, a combined fit of MINOS and MINOS+ data gives a stronger limit on θ24 in the range of 10-2 eV2 < Δm412 < 1 eV2 than previous experiments. For LED, with the complete MINOS data set, the size of extra dimensions is constrained to be smaller than ~ 0.35 μm at 90% C.L. in the limit of a vanishing lightest neutrino mass.

  1. Sterile insect technique for the management of the oriental fruit fly in Guimaras iasland

    International Nuclear Information System (INIS)

    Golez, H.; Manoto, E.

    1996-01-01

    Mango is an important fruit crop in the country as shown by increasing demand for the fruit both in local and domestic markets. In particular, the island of Guimaras is now being developed as the mango province of the country since the soil and climate are highly suitable for its growth and development. Today, there are more than 250,000 trees grown in the island and the local government plans to plant more than 1 million trees by the year 2000. The production of quality fruits is however, hampered by the presence of fruit flies. A new strategy in fruit fly control is the sterile insect technique which will be implemented in the island of Guimaras. SIT involves mass rearing, sterilization and release of sterile fruit flies in target areas to stop native flies from reproducing. Preparatory phase of the project include campaigns launched to inform growers, government officials and private sectors on the objectives and mechanics of SIT through press releases, workshops and meetings. Basic ecological studies which involved determination of host fruits, degree of fruit infestation, population dynamics and fruit fly dispersal are presented. Estimates of fruit fly population showed that more insects were present in natural vegetation as compared to mix plantation and low population was recorded in pure orchards. Preliminary results of male annihilation technique using a bait consisting of methyl eugenol and malathion placed in fiber boards also revealed that male populations were reduced to low levels, provided that wide area approach is considered. Otherwise, reinfestation of limited areas by flies will occur. Continuous monitoring of flies in the whole island is now being undertaken. Sterile insect technique was demonstrated in the small islet of Naoay, south west of the main island of Guimaras. Results of several releases showed that no unmarked flies were captured from monitoring traps, indicating that sterile flies suppressed the population of wild flies in the area

  2. Study on blood compatibility of the radiation sterilized disposable burette transfusion apparatus

    International Nuclear Information System (INIS)

    Chen Guochong; Liu Wen; Liu Qingfang

    2011-01-01

    The blood compatibility of the radiation sterilized disposable burette transfusion apparatus was investigated to provide evidence for the safety of radiation sterilized medical devices. The initial bacteria burden of the disposable burette transfusion apparatus was examined according to the ISO11737 standard, and the whole blood clotting time, prothrombin time, partial thromboplastin time and hemolysis rate of the samples were determined. There was no significant difference between the radiation sterilized samples and negative controls on WBCT, PT and PTT (p>0.05). Haemolysis test showed that the haemolysis rate of the sample sterilized by irradiation was 1.38%, which was coincidence with the criteria of the medical devices. After sterilization by irradiation, disposable burette transfusion apparatus show good blood compatibility, which could be considered that radiation sterilization is a biologically safe method for the medical apparatus. (authors)

  3. Low temperature gamma sterilization of a bioresorbable polymer, PLGA

    Science.gov (United States)

    Davison, Lisa; Themistou, Efrosyni; Buchanan, Fraser; Cunningham, Eoin

    2018-02-01

    Medical devices destined for insertion into the body must be sterilised before implantation to prevent infection or other complications. Emerging biomaterials, for example bioresorbable polymers, can experience changes in their properties due to standard industrial sterilization processes. Gamma irradiation is one of the most reliable, large scale sterilization methods, however it can induce chain scission, cross-linking or oxidation reactions in polymers. sterilization at low temperature or in an inert atmosphere has been reported to reduce the negative effects of gamma irradiation. The aim of this study was to investigate the impact of low temperature sterilization (at -80 °C) when compared to sterilization at ambient temperature (25 °C) both in inert atmospheric conditions of nitrogen gas, on poly(lactide co-glycolide) (PLGA). PLGA was irradiated at -80 and 25 °C at 40 kGy in a nitrogen atmosphere. Samples were characterised using differential scanning calorimetry (DSC), tensile test, Fourier transform infrared (FTIR) spectroscopy, proton nuclear magnetic resonance (1H NMR) spectroscopy and gel permeation chromatography (GPC). The results showed that the molecular weight was significantly reduced as was the glass transition temperature, an indication of chain scission. FTIR showed small changes in chemical structure in the methyl and carbonyl groups after irradiation. Glass transition temperature was significantly different between irradiation at -80 °C and irradiation at 25 °C, however this was a difference of only 1 °C. Ultimately, the results indicate that the sterilization temperature used does not affect PLGA when carried out in a nitrogen atmosphere.

  4. Sterilization of microorganisms by the supercritical carbon dioxide micro-bubble method.

    Science.gov (United States)

    Ishikawa, H; Shimoda, M; Shiratsuchi, H; Osajima, Y

    1995-10-01

    Lactobacillus brevis and Saccharomyces cerevisiae were completely sterilized by the supercritical (SC) CO2 micro-bubble method. Gaseous (G) and liquid (LQ) CO2 were used in a similar manner to compare the sterilizing effect. Among the three treatments, the microorganisms were only effectively sterilized by the SC CO2 treatment at 25 MPa and 35 degrees C.

  5. NF EN ISO 11137-1, July 2006. Sterilization of health care products - Irradiation - Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices

    International Nuclear Information System (INIS)

    2006-01-01

    This part of the ISO 11137 standard specifies requirements for the development, validation and routine control of a radiation sterilization process for medical devices. Although the scope of this part of the ISO 11137 standard is limited to medical devices, it specifies requirements and provides guidance that may be applicable to other products and equipment. This part of the international standard covers radiation processes employing irradiators using the radionuclide 60 Co or 137 Cs, a beam from an electron generator or a beam from an X-ray generator. This part of the international standard does not: - specify requirements for development, validation and routine control of a process for inactivating the causative agents of spongiform encephalopathies such as scrapie, bovine spongiform encephalopathy and Creutzfeldt-Jakob disease; - detail specified requirements for designating a medical device as sterile; - specify a quality management system for the control of all stages of production of medical devices; - specify requirements for occupational safety associated with the design and operation of irradiation facilities; - specify requirements for the sterilization of used or reprocessed devices

  6. Efficient transformation of Kalanchoe blossfeldiana and production of male-sterile plants by engineered anther ablation.

    Science.gov (United States)

    García-Sogo, Begoña; Pineda, Benito; Castelblanque, Lourdes; Antón, Teresa; Medina, Mónica; Roque, Edelín; Torresi, Claudia; Beltrán, José Pío; Moreno, Vicente; Cañas, Luis Antonio

    2010-01-01

    Engineered male sterility in ornamental plants has many applications such as facilitate hybrid seed production, eliminate pollen allergens, reduce the need for deadheading to extend the flowering period, redirect resources from seeds to vegetative growth, increase flower longevity and prevent gene flow between genetically modified and related native plants. We have developed a reliable and efficient Agrobacterium-mediated protocol for the genetic transformation of different Kalanchoe blossfeldiana commercial cultivars. Transformation efficiency for cv. 'Hillary' was 55.3% whereas that of cv. 'Tenorio' reached 75.8%. Selection was carried out with the nptII gene and increasing the kanamycin concentration from 25 to 100 mg l(-1) allowed to reduced escapes from 50 to 60% to virtually 0%. This method was used to produce male-sterile plants through engineered anther ablation. In our approach, we tested a male sterility chimaeric gene construct (PsEND1::barnase) to evaluate its effectiveness and effect on phenotype. No significant differences were found in the growth patterns between the transgenic lines and the wild-type plants. No viable pollen grains were observed in the ablated anthers of any of the lines carrying the PsEND1::barnase construct, indicating that the male sterility was complete. In addition, seed set was completely abolished in all the transgenic plants obtained. Our engineered male-sterile approach could be used, alone or in combination with a female-sterility system, to reduce the invasive potential of new ornamentals, which has become an important environmental problem in many countries.

  7. Prospects for the future development and application of the sterile insect technique

    International Nuclear Information System (INIS)

    Robinson, A.S.; Hendrichs, J.

    2005-01-01

    Science-based modern agriculture and international trade in agricultural commodities have achieved that, even though the world population has doubled in the last 40 years, the absolute number of people in poverty and hunger has been falling steadily. The major challenge in the immediate future is to consolidate these positive gains, while simultaneously expanding environment-friendly agricultural practices. Within this context, the sterile insect technique (SIT), as part of area-wide integrated pest management (AW-IPM) programmes, will continue to gain momentum for application against certain key insect pests. This is in response to the demands for cleaner food and a better environment, the need to facilitate increasing international trade by overcoming pest related trade barriers to the movement of agricultural commodities, and the imperative of dealing with the increasing invasion of exotic pests. As the use of the technology increases, changes will continue to be made to improve the overall efficiency of the technique for those species where the SIT is already being used, and to expand the use of the technique to new key species. Modem biotechnology may also contribute to improving efficiency and, even though there are as yet no transgenic strains of pest insects that could be used in AW-IPM programmes, transgenic technology may eventually benefit these programmes in terms of strain marking, genetic sexing, molecular sterilization, and disease refractoriness; however, first the regulatory hurdle to allow their use will have to be overcome. There appears to be much promise in improving sterile male performance by exposing male insects to hormonal, nutritional, microbial, and semiochemical supplements. Furthermore, the management of mother colonies will be significantly improved to reduce the effects of colonization and to slow down mass-rearing effects on key behavioural parameters that often result in rapid colony deterioration. Progress will also need to be

  8. Periodontal instrumentation for the general dental practitioner: Pt. 2. Management maintenance and sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Touyz, L.Z.G. (University of the Witwatersrand, Johannesburg (South Africa). Dept. of Oral Medicine and Periodontology); De Waal, J.

    1983-03-01

    The purpose of this article is to describe the management, maintenance and sterilization of periodontal instrumentation used by the general dental practitioner. The pre-sterilization, decontamination and cleaning, the sharpening of instrumentation and the packaging, identification and grouping for sterilization are discussed. Attention is also given to various techniques of sterilization, including gamma radiation.

  9. [Juvenile sterile granulomatous dermatitis and lymphadenitis in the dog].

    Science.gov (United States)

    Weingart, C; Eule, C; Welle, M; Kohn, B

    2011-04-01

    Juvenile sterile granulomatous dermatitis and lymphadenitis is a rare immune-mediated skin disease in young dogs. History, signalment, diagnostics, treatment, and outcome in 10 dogs are described. The age ranged from 8 - 36 weeks. The lymph nodes were enlarged in all dogs, especially the mandibular and prescapular lymph nodes. Systemic signs including fever were present in 8 dogs. Seven dogs suffered from blepharitis and painful edema of the muzzle with hemorrhagic discharge, pustules and papules. Cytology of pustules and lymph node aspirates revealed a pyogranulomatous inflammation. In 7 cases the diagnosis of juvenile sterile granulomatous dermatitis and lymphadenitis was confirmed by histology. Nine dogs were treated with prednisolone (0.5 - 1.25 mg/kg BID), H2-receptor antagonists and analgetics; all dogs were treated with antibiotics. Four dogs were treated with eye ointment containing antibiotics and glucocorticoids. The prednisolone dosage was tapered over 3 - 8 weeks. One dog had a relapse.

  10. Transcriptional regulation of male-sterility in 7B-1 male-sterile tomato mutant.

    Directory of Open Access Journals (Sweden)

    Vahid Omidvar

    Full Text Available The 7B-1 tomato (Solanum lycopersicum L. cv Rutgers is a male-sterile mutant with enhanced tolerance to abiotic stress, which makes it a potential candidate for hybrid seed breeding and stress engineering. To underline the molecular mechanism regulating the male-sterility in 7B-1, transcriptomic profiles of the 7B-1 male-sterile and wild type (WT anthers were studied using mRNA sequencing (RNA-Seq. In total, 768 differentially expressed genes (DEGs were identified, including 132 up-regulated and 636 down-regulated transcripts. Gene ontology (GO enrichment analysis of DEGs suggested a general impact of the 7B-1 mutation on metabolic processes, such as proteolysis and carbohydrate catabolic process. Sixteen candidates with key roles in regulation of anther development were subjected to further analysis using qRT-PCR and in situ hybridization. Cytological studies showed several defects associated with anther development in the 7B-1 mutant, including unsynchronized anther maturation, dysfunctional meiosis, arrested microspores, defect in callose degradation and abnormal tapetum development. TUNEL assay showed a defect in programmed cell death (PCD of tapetal cells in 7B-1 anthers. The present study provides insights into the transcriptome of the 7B-1 mutant. We identified several genes with altered expression level in 7B-1 (including beta-1,3 glucanase, GA2oxs, cystatin, cysteine protease, pectinesterase, TA29, and actin that could potentially regulate anther developmental processes, such as meiosis, tapetum development, and cell-wall formation/degradation.

  11. Resonant Production of Sterile Neutrinos in the Early Universe

    Science.gov (United States)

    Gilbert, Lauren; Grohs, Evan; Fuller, George M.

    2016-06-01

    This study examines the cosmological impacts of a light resonantly produced sterile neutrino in the early universe. Such a neutrino could be produced through lepton number-driven Mikheyev-Smirnov-Wolfenstein (MSW) conversion of active neutrinos around big bang nucleosynthesis (BBN), resulting in a non-thermal spectrum of both sterile and electron neutrinos. During BBN, the neutron-proton ratio depends sensitively on the electron neutrino flux. If electron neutrinos are being converted to sterile neutrinos, this makes the n/p ratio a probe of possible new physics. We use observations of primordial Yp and D/H to place limits on this process.

  12. 40 CFR 63.10420 - How do I demonstrate continuous compliance with the management practice requirements?

    Science.gov (United States)

    2010-07-01

    ... compliance with the management practice requirements? 63.10420 Section 63.10420 Protection of Environment... continuous compliance with the management practice requirements? For each sterilization unit not equipped with an air pollution control device, you must demonstrate continuous compliance with the management...

  13. Natural convection heating of liquids, with reference to sterilization of canned food

    NARCIS (Netherlands)

    Hiddink, J.

    1975-01-01

    In a model system the physical transport phenomena that occur during the sterilization of a canned liquid food were investigated. Flow phenomena and heat transfer were studied experimentally as well as theoretically. Experiments on flow patterns and temperature profiles revealed a boundary

  14. Sterilization studies on the adult indian meal moth, plodia interpunctella (HUBNER)

    International Nuclear Information System (INIS)

    Boshra, S.A.; Hasaballa, Z.A.

    1993-01-01

    The effects of gamma radiation doses ranging between 10 and 65 krad on adult plodia interpunctella (Hubner) were studied. Irradiation of adult affected clearly the egg production and fertility of both sexes at different mating combinations. Females were more sensitive to the sterilizing effects of gamma radiation than males. Complete sterility of females and males was achieved at 50 and 65 krad, respectively. Replacing normal males by sterile ones in the normal population decreased the egg hatch ability when compared with the control population. Newly emerged unmated females laid completely infertile eggs when confined with irradiated (65 krad) males, whether mating occurred on the day of treatment or 2 days after treatment. Sterilized males were able to compete with normal ones in a population at the highest flooding ratios. Adding sterile females to this competing population gave excellent results.5 tab

  15. Sterile neutrino search with the Double Chooz experiment

    Energy Technology Data Exchange (ETDEWEB)

    Hellwig, Denise; Bekman, Ilja; Kampmann, Philipp; Schoppmann, Stefan; Soiron, Michael; Stahl, Achim; Wiebusch, Christopher [III. Physikalisches Institut B, RWTH Aachen (Germany)

    2016-07-01

    The Double Chooz experiment is a reactor neutrino disappearance experiment located at the Chooz nuclear power plant, France. It measures the electron-antineutrino flux of the two nuclear reactors with two detectors of identical design. A far detector at a distance of about 1 km is operating since 2011; a near detector at a distance of about 400 m is operating since the end of 2014. The combination of the two detectors offers sensitivity to sterile neutrino mixing parameters. Sterile neutrinos are neutrino mass states not taking part in weak interactions, but may mix with known neutrino states. This induces additional mixing angles and mass differences. This talk describes the search for sterile neutrinos and the sensitivity of Double Chooz to the mixing angle θ{sub 14}.

  16. Research on dose setting for radiation sterilization of medical device

    International Nuclear Information System (INIS)

    Zhang Tongcheng; Liu Qingfang; Zhong Hongliang; Mi Zhisu; Wang Chunlei; Jiang Jianping

    2002-01-01

    Objective: To establish the radiation sterilization dose for medical devices using data of bioburden on the medical device. Methods: Firstly determination of recovery ratio and correction coefficient of the microbiological test method was used according to ISO11737 standard, then determination of bioburden on the products, finally the dose setting was completed based on the Method 1 in ISO11137 standard. Results: Fifteen kinds of medical devices were tested. Bioburden range was from 8.6-97271.2 CFU/device, recovery ration range 54.6%-100%, correction co-efficiency range 1.00-1.83, D 10 distribution from 1.40 to 2.82 kGy, verification dose (dose at SAL = 10 -2 ) range 5.1-17.6 kGy and sterilization dose (dose at SAL 10 -6 ) range 17.5-32.5 kGy. Conclusion: One hundred samples of each kind of product were exposed to the pre-determined verification dose and then the sterility test was performed. Each sterility test showed positive number was not greater than two. This indicated that the sterilization dose established for each kind of product was statistically acceptable

  17. Practical aspects during sterilization validation for medical devices at IRASM Microbiological Laboratory

    International Nuclear Information System (INIS)

    Trandafir, L.; Ene, M.; Alexandru, M.; Constantin, M.; Ionita, A.; Zorila, F.; Moise, I.V.

    2011-01-01

    Complete text of publication follows. The state of being free of living microorganisms is called sterility. The sterility state can be achieved by different means of sterilization. In practice the results of the process cannot be fully verified by tests, so the efficacy of the sterilization process must be validated. ISO 11137 established regulations for setting or substantiating the dose for achieving the desired sterility assurance level. The validation studies can be designed in particular for different types of product. Each product needs distinct protocol for bioburden determination and sterility testing. During time, the Microbiological Laboratories from Multipurpose Irradiation Center deals with different types of products, mainly for VD max 25 method. When it comes to microbiological evaluation the most challenging was cotton gauze. Special situation for establishing the sterilization validation method appears in cases of cotton, packed in large quantities. VD max 25 method can not be applied for items with average bioburden more than 1000 CFU / pack, no matter which is the weight of the package. This is a method limitation and implies increased costs for manufacturer, when choosing other method. For microbiological tests, culture condition should be selected in both cases the bioburden and sterility testing. These are time and money consuming. The costs can be reduced if taking into account some aspects. Reason for performing the bacteriostasis-fungistasis just for sterility testing will be given. The present study puts forward aspects during the validation studies for medical devices (cotton wool, cotton gauze, surgical sutures, dental screws), at IRASM Microbiological Laboratory.

  18. Cytoplasmic male sterility contributes to hybrid incompatibility between subspecies of Arabidopsis lyrata.

    Science.gov (United States)

    Aalto, Esa A; Koelewijn, Hans-Peter; Savolainen, Outi

    2013-10-03

    In crosses between evolutionarily diverged populations, genomic incompatibilities may result in sterile hybrids, indicating evolution of reproductive isolation. In several plant families, crosses within a population can also lead to male sterile progeny because of conflict between the maternally and biparentally inherited genomes. We examined hybrid fertility between subspecies of the perennial outcrossing self-incompatible Lyrate rockcress (Arabidopsis lyrata) in large reciprocal F2 progenies and three generations of backcrosses. In one of the reciprocal F2 progenies, almost one-fourth of the plants were male-sterile. Correspondingly, almost one-half of the plants in one of the four reciprocal backcross progenies expressed male sterility. In an additional four independent F2 and backcross families, three segregated male sterility. The observed asymmetrical hybrid incompatibility is attributable to male sterility factors in one cytoplasm, for which the other population lacks effective fertility restorers. Genotyping of 96 molecular markers and quantitative trait locus mapping revealed that only 60% of the plants having the male sterile cytoplasm and lacking the corresponding restorers were phenotypically male-sterile. Genotyping data showed that there is only one restorer locus, which mapped to a 600-kb interval at the top of chromosome 2 in a region containing a cluster of pentatricopeptide repeat genes. Male fertility showed no trade-off with seed production. We discuss the role of cytoplasm and genomic conflict in incipient speciation and conclude that cytoplasmic male sterility-lowering hybrid fitness is a transient effect with limited potential to form permanent reproductive barriers between diverged populations of hermaphrodite self-incompatible species.

  19. Thermalisation of light sterile neutrinos in the early universe

    DEFF Research Database (Denmark)

    Hannestad, Steen; Tamborra, Irene; Tram, Thomas

    2012-01-01

    on the current cosmological data have been derived using simplified assumptions about thermalisation of the sterile neutrino at the Big Bang Nucleosynthesis (BBN) epoch. These assumptions are not necessarily justified and here we solve the full quantum kinetic equations in the (1 active + 1 sterile) scenario...

  20. Studies on mating competitiveness of sterile oriental fruit fly, Bactrocera dorsalis (Hendel)

    International Nuclear Information System (INIS)

    Limohpasmanee, W.; Segsarnviriya, S.

    1998-01-01

    An essential prerequisite for insect control by the sterile insect technique releasing method is mass rearing and sterilizing that do not have adverse effects on longevity and mating behavior of the released males. But many laboratory studies have shown that males irradiated at the completely sterility dose often could not compete with untreated males in mating. This paper studies the effects of gamma radiation at the sterile dose on mating, sexual and sperm competitiveness of the oriental fruit fly, Bactrocera dorsalis (Hendel) under the laboratory condition. It is found that irradiation at the completely sterility dose (90 Gy) had reduced the mating and sperm competition ability of the males. Though the sexual competition was not

  1. Study on irradiation sterilization of medical gauze pad by incremental dosage method

    International Nuclear Information System (INIS)

    Lei Qing; Huang Min; Deng Wenmin; Wu Ling; Wang Yan; Gao Peng; Du Xiaoying; Xie Yan

    2011-01-01

    To explore the sterilization dose setting method for medical products, the irradiation sterilization dose for medical products was set according to the method 2A of international standard ISO11137 Part 2. The verification dose for medical gauze pad by was set by incremental dose method and with a series of formula. Then the sterilization dose for an SAL of 10 -6 was established by completing the verification dose experiment. The final sterilization dose for medical gauze pad was decided to be 29.7 kGy. This study gives reference for the setting irradiation sterilization dose for medical products which need to adopt the method 2A of international standard ISO11137 Part 2. (authors)

  2. Mirror model for sterile neutrinos

    International Nuclear Information System (INIS)

    Berezinsky, Veniamin; Narayan, Mohan; Vissani, Francesco

    2003-01-01

    Sterile neutrinos are studied as subdominant contribution to solar neutrino physics. The mirror-matter neutrinos are considered as sterile neutrinos. We use the symmetric mirror model with gravitational communication between mirror and visible sectors. This communication term provides mixing between visible and mirror neutrinos with the basic scale μ=v EW 2 /M Pl =2.5x10 -6 eV, where v EW =174 GeV is the vacuum expectation value of the standard electroweak group and M Pl is the Planckian mass. It is demonstrated that each mass eigenstate of active neutrinos splits into two states separated by small Δm 2 . Unsuppressed oscillations between active and sterile neutrinos (ν a ↔ν s ) occur only in transitions between each of these close pairs ('windows'). These oscillations are characterized by very small Δm 2 and can suppress the flux and distort spectrum of pp-neutrinos in detectable way. The other observable effect is anomalous seasonal variation of neutrino flux, which appears in LMA solution. The considered subdominant neutrino oscillations ν a ↔ν s can reveal itself as big effects in observations of supernova neutrinos and high-energy (HE) neutrinos. In the case of HE neutrinos they can provide a very large diffuse flux of active neutrinos unconstrained by the e-m cascade upper limit

  3. Design, Construction and Evaluation of a Dry Solar Sterilizer

    International Nuclear Information System (INIS)

    Hernández Fereira, Arcelio A.

    2017-01-01

    The objective of the work was the search of an alternative for sterilization using solar energy. For such purposes, a dry solar sterilizer of 4276 cm3 capacity was designed, constructed and evaluated. Potential users would be rural medical posts in areas without electricity, health posts in military units under field conditions, and experimental microbiology stations. The evaluation included the determination of the energy efficiency of the sterilizer, the economic evaluation against other variants and the biological safety assessment. The developed equipment reached the sterilization temperature for levels of the direct component of the solar radiation higher than 300 W/m2 in 14 minutes, corresponding to an average heating rate of 13 0C/minute, higher than that of an electric furnace. Its energy efficiency with direct solar radiation of 310.5 W/m2 was 53.79%. The equipment is of easy construction, simple operation and very low cost. (author)

  4. Monitoring sterile and wild insects in area-wide integrated pest management programmes

    International Nuclear Information System (INIS)

    Vreysen, M.J.B.

    2005-01-01

    Insect pest control programmes, which integrate the release of sterile insects, can be efficient only if the released insects have an optimal biological quality. Frequent monitoring of the quality of reared insects after being released in the field is an important but often neglected component of area-wide integrated pest management (AW-IPM) programmes that integrate the sterile insect technique (SIT). Parameters of sterile insects, which should be monitored regularly, are sexual competitiveness of the released insects, and related components, e.g. survival, mobility, dispersal characteristics, and spatial occupation of the habitat. A well-balanced monitoring programme will, at any given time, provide essential feedback on the progress being made. This information is prerequisite to efficient implementation of the release and cost-efficient use of sterile insects. The type of monitoring to be done will be determined largely by the particular biology of the target insect species. The most important parameter in relation to the release of sterile insects is the rate of sterility induced in the wild insect pest population; it will provide the best evidence that any observed changes, e.g. in the density of the target insect, are caused by the release of sterile insects. (author)

  5. Sterilization of Carriers by using Gamma Irradiation for Bio fertilizer Inoculum Production

    International Nuclear Information System (INIS)

    Tittabutr, Panlada; Teamtisong, Kamonluck; Pewlong, Wachiraporn; Teaumroong, Neuhg; Laoharojanaphand, Sirinart; Boonkerd, Nantakorn

    2009-07-01

    Full text: Gamma irradiation has been widely used in sterilization process, which leads to improvement in the quality of the products. In the case of bio fertilizer inoculum, the sterilized carrier is also needed for producing high quality bio fertilizer. This study aimed at determining the factors, such as carrier materials, moistures, and packing sizes including packaging materials that may affect the sterilization efficiency by using gamma irradiation. All carrier materials, peat and compost, could be efficiently sterilized by irradiation. The carriers that have moisture content lower than 20% could be sterilized by irradiation at 15 kGy, while carrier with 30% moisture content must be sterilized by irradiation at 25 kGy. Higher irradiation dose was also necessary for sterilization of bigger carrier packing sizes. For, packaging materials, polyethylene bag appeared most durable after gamma irradiation even at high doses. However, contaminants could be detected in irradiated carrier after storage at room temperature for two months. It was hypothesized that these contaminants are spore forming microorganisms, which resist gamma irradiation. This hypothesis, as well as the quality of bio fertilizer produced from irradiated carrier, will be further evaluated

  6. Preliminary studies on male sterile mutant after exogenous DNA introduced into wheat

    International Nuclear Information System (INIS)

    Yang Jingcheng; Yu Yuanjie; Qi Yanfang

    2004-01-01

    A stable sterile line--D-type sterile line was obtained after exogenous λDNA introduced into wheat line 814527. There were obvious characters in flower structure of the sterile line. The number of ovaries increased and that of anthers declined, and the sum was not always equal to four. Polygynous flower were located in the middle of panicles, while there were no polygynous ones on the top and the base of panicles. The main ovary was in the center of the flower, and the accessory ovaries surrounded to main ovary. The ovaries did not develop synchronously, main ovary developed earlier and accessory ones slower. The volume of main ovary was bigger than the accessory ones. Anthers of the sterile line with abnormal shapes were obsolescent at early stage, and had no living pollen. It showed that the sterile line was a cytoplasmic male sterile one, and the acceptor line 814527 could be its maintainer. The hybrid of the sterile line and Lumai 14 had some heterosis in traits such as panicle length, spikelet number per panicle and grain number per panicle, and its yield per plant was 11.6% higher than that of Lumai 14

  7. Essure hysteroscopic sterilization versus interval laparoscopic bilateral tubal ligation: a comparative effectiveness review.

    Science.gov (United States)

    Ouzounelli, Myrsini; Reaven, Nancy L

    2015-01-01

    A comparative effectiveness analysis was performed to examine the risks and benefits of laparoscopic bilateral tubal ligation compared with hysteroscopic sterilization using the Essure Permanent Birth Control System (Bayer HealthCare AG, Whippany, NJ). Existing evidence shows that both LBTL and Essure are safe and effective methods of female sterilization. Both have high rates of efficacy and low rates of complications although when complications do occur, those related to the Essure procedure are more likely to be minor in nature. The analysis was limited by the restricted number of studies involving head-to-head comparisons of the 2 approaches. Copyright © 2015 AAGL. Published by Elsevier Inc. All rights reserved.

  8. Effect of sterilization process on surface characteristics and biocompatibility of pure Mg and MgCa alloys

    International Nuclear Information System (INIS)

    Liu, X.L.; Zhou, W.R.; Wu, Y.H.; Cheng, Y.; Zheng, Y.F.

    2013-01-01

    The aim of this work was to investigate the effect of various sterilization methods on surface characteristics and biocompatibility of MgCa alloy, with pure Mg as a comparison, including steam autoclave sterilization (SA), ethylene oxide steam sterilization (EO), glutaraldehyde sterilization (GD), dry heat sterilization (DH) and Co60 γ ray radiation sterilization (R) technologies. The surface characterizations were performed by environmental scanning electron microscopy, energy-dispersive X-ray spectroscopy, X-ray photoelectron spectroscopy, grazing incidence X-ray diffraction, water contact angle and surface free energy measurement, whereas the cytotoxicity and hemocompatibility were evaluated by cellular adhesive experiment, platelet adhesion and hemolysis test. The results showed that the five sterilization processes caused more changes on the surface of MgCa alloy than that on the surface of pure Mg. The GD sterilization caused the most obvious changes on the surface of the pure Mg, and the SA sterilization made the largest alteration on the MgCa alloy surface. The GD and DH sterilization processes could cause increases on surface free energy for both pure Mg and MgCa alloys, while the other three sterilization processes reduced the surface free energy. The DH and GD sterilization processes caused the least alteration on the cell adhesion on pure Mg surface, whereas the EO sterilization performed the greatest impact on the cell adhesion on the Mg–Ca alloy surface. The hemolysis percentage of pure Mg and MgCa alloys were reduced by SA sterilization, meanwhile the other four sterilization processes increased their hemolysis percentages significantly, especially for the EO sterilization. - Highlights: • The effect of sterilization on surface chemistry and biocompatibility was studied. • Sterilization caused more surface changes on MgCa alloy than pure Mg. • Co60 γ ray radiation is the most appropriate sterilization process

  9. A White Paper on keV Sterile Neutrino Dark Matter

    DEFF Research Database (Denmark)

    Adhikari, R.; Agostini, M.; Ky, N. Anh

    2016-01-01

    We present a comprehensive review of keV-scale sterile neutrino Dark Matter, collecting views and insights from all disciplines involved - cosmology, astrophysics, nuclear, and particle physics - in each case viewed from both theoretical and experimental/observational perspectives. After reviewing...... the role of active neutrinos in particle physics, astrophysics, and cosmology, we focus on sterile neutrinos in the context of the Dark Matter puzzle. Here, we first review the physics motivation for sterile neutrino Dark Matter, based on challenges and tensions in purely cold Dark Matter scenarios. We...... then round out the discussion by critically summarizing all known constraints on sterile neutrino Dark Matter arising from astrophysical observations, laboratory experiments, and theoretical considerations. In this context, we provide a balanced discourse on the possibly positive signal from X...

  10. Sterile diets for the immuno-compromised: Is there a need?

    Science.gov (United States)

    Butterweck, Joseph S.

    1995-02-01

    There is a general misunderstanding in the radiation processing industry about the use of sterile diets in the medical profession. Sterile diets are used on a limited basis in hospitals that specialize in cancer treatment and organ transplants. These patients are severely immuno-compromised. There are many other patients that are immuno-compromised that do not require sterile diets. These patients may require a diet that is pathogen-free and are aslo "low-microbial diets". Nosocomial infections have become a major issue in US hospitals. The "infection control committee" is the focus group responsible to assure nosocomial infections incidence are below the hospital goals. Application of ionizing radiation to sterilize diets has not been chosen because the product is not available at a reasonable total cost. This paper will discuss the hospitals views.

  11. Sterile diets for the immuno-comprised: is there a need?

    International Nuclear Information System (INIS)

    Butterweck, J.S.

    1995-01-01

    There is a general misunderstanding in the radiation processing industry about the use of sterile diets in the medical profession. Sterile diets are used on a limited basis in hospitals that specialize in cancer treatment and organ transplants. These patients are severely immuno-compromised. There are many other patients that are immuno-compromised that do not require sterile diets. These patients may require a diet that is pathogen-free and are also ''low-microbial diets''. Nosocomial infections have become a major issue in US hospitals. The ''infection control committee'' is the focus group responsible to assure nosocomial infections incidence are below the hospital goals. Application of ionizing radiation to sterilize diets has not been chosen because the product is not available at a reasonable total cost. This paper will discuss the hospitals views. (Author)

  12. Study of the compatibility and competitiveness of sterile males in the framework of the struggle by the sterile insect technique against the Ceratitis

    International Nuclear Information System (INIS)

    Azzabi, Jihene

    2007-01-01

    We evaluated under semi-natural field-cage conditions sexual compatibility and competitivity of laboratory strain (Genetic Sexing Strain GSS) ''Vienna 8''. The GSS strain is produced under mass (rearing conditions at the facility of production of sterile males at Sidi Thabat. Wild flies were obtained from infested Sommer oranges. Twenty-five wild males, 25 wild females and 25 GSS were released into cage and mating pairs collected. The determination of indices such as the Isolation Index (ISI), the Male Relative Index (MRPI), the Stalker Index (I) and the Relative Sterile Index (RSI) shows that there is no compatibility and competitiveness between the two strains with a tendency to behaviour of sexual isolation. Sterile male tests dissection irradiated at the dose of (0 Gy, 110 Gy, 120 Gy, 130 Gy and 145 Gy) and correspondent female spermatic show the important damage of the irradiation on the cells but decrease the quality of the sterile male (mating duration, sperm transfer.). (Author)

  13. The economics of race and eugenic sterilization in North Carolina: 1958-1968.

    Science.gov (United States)

    Price, Gregory N; Darity, William A

    2010-07-01

    Theoretical justifications for state-sanctioned sterilization of individuals provided by Irving Fisher rationalized its racialization on grounds that certain non-white racial groups, particularly blacks due to their dysgenic biological and behavioral traits, retarded economic growth and should be bred out of existence. Fisher's rationale suggests that national or state level eugenic policies that sterilized the so-called biological and genetically unfit could have been racist in both design and effect by disproportionately targeting black Americans. We empirically explore this with data on eugenic sterilizations in the State of North Carolina between 1958 and 1968. Count data parameter estimates from a cross-county population allocation model of sterilization reveal that the probability of non-institutional and total sterilizations increased with a county's black population share-an effect not found for any other racial group in the population. Our results suggest that in North Carolina, eugenic sterilization policies were racially biased and genocidal. 2010 Elsevier B.V. All rights reserved.

  14. More is different: Reconciling eV sterile neutrinos with cosmological mass bounds

    Directory of Open Access Journals (Sweden)

    Yong Tang

    2015-11-01

    Full Text Available It is generally expected that adding light sterile species would increase the effective number of neutrinos, Neff. In this paper we discuss a scenario that Neff can actually decrease due to the neutrino oscillation effect if sterile neutrinos have self-interactions. We specifically focus on the eV mass range, as suggested by the neutrino anomalies. With large self-interactions, sterile neutrinos are not fully thermalized in the early Universe because of the suppressed effective mixing angle or matter effect. As the Universe cools down, flavor equilibrium between active and sterile species can be reached after big bang nucleosynthesis (BBN epoch, but leading to a decrease of Neff. In such a scenario, we also show that the conflict with cosmological mass bounds on the additional sterile neutrinos can be relaxed further when more light species are introduced. To be consistent with the latest Planck results, at least 3 sterile species are needed.

  15. Counselling women considering or seeking sterilization.

    Science.gov (United States)

    Jackson, T

    1980-12-01

    The view of counseling as assessment and advice-giving places unrealistic and unnecessary stresses on both counselor and client. The counselor-doctor feels responsible for client's subsequent happiness in life and feels guilty if his advice leads to future unhappiness for her. The client feels powerless in the decision-making process and has less incentive to take full responsibility for the direction of her life. A review of studies of emotional adjustment to sterilization revealed a lack of clearly defined goals for preoperative counseling and the failure to test in any way the effect of different models of counseling on client outcome. Issues which might be raised with a woman considering sterilization may be grouped into 4: 1) the woman's life situation; 2) her reasons for considering sterilization; 3) timing; and 4) ambivalence. Counselors should be prepared for and comfortable with the expression of emotion in counseling sessions. Counselors who themselves are unable to cope with expression of intense emotion will send conflicting messages to clients, both giving permission for and disapproving of exploration of certain levels of feeling. The concept of 'regret' as an outcome measure should be refined.

  16. Genetic basis of hybrid male sterility among three closely related species of Drosophila.

    Science.gov (United States)

    Mishra, Paras Kumar; Singh, B N

    2005-05-01

    The genetic basis of hybrid male sterility among three closely related species, Drosophila bipectinata, D. parabipectinata and D. malerkotliana has been investigated by using backcross analysis methods. The role of Y chromosome, major hybrid sterility (MHS) genes (genetic factors) and cytoplasm (non-genetic factor) have been studied in the hybrids of these three species. In the species pair, bipectinata--parabipectinata, Y chromosome introgression of parabipectinata in the genomic background of bipectinata and the reciprocal Y chromosome introgression were unsuccessful as all males in second backcross generation were sterile. Neither MHS genes nor cytoplasm was found important for sterility. This suggests the involvement of X-Y, X-autosomes or polygenic interactions in hybrid male sterility. In bipectinata--malerkotliana and parabipectinata--malerkotliana species pairs, Y chromosome substitution in reciprocal crosses did not affect male fertility. Backcross analyses also show no involvement of MHS genes or cytoplasm in hybrid male sterility in these two species pairs. Therefore, X- autosome interaction or polygenic interaction is supposed to be involved in hybrid male sterility in these two species pairs. These findings also provide evidence that even in closely related species, genetic interactions underlying hybrid male sterility may vary.

  17. Influence of different sterilization processes on the properties of commercial poly(lactic acid)

    International Nuclear Information System (INIS)

    Savaris, M.; Santos, V. dos; Brandalise, R.N.

    2016-01-01

    This study aims at analyzing the modifications in the morphological, physical, chemical and thermal properties of commercial poly(lactic acid) (PLA) films after exposure to five different sterilization processes. Films were obtained by compression molding, hygienized and sterilized by ethylene oxide (SEtO), hydrogen peroxide plasma (SH 2 O 2 ), saturated steam (SSS), electron beam radiation (SEB) and gamma radiation (SGR). The samples of PLA SEtO , PLA SH2O2 , PLA SEB and PLA SGR exhibited thermal and physical changes after being submitted to sterilization processes. PLA SSS showed morphological, chemical, thermal and physical changes. It is concluded that processes by SEtO, SH 2 O 2 , SEB and EGR can be applied for the sterilization of PLA films and the SSS process is not recommended in view of the data obtained and test conditions reported in this study for PLA films. - Highlights: • PLA was subjected to five different sterilization process. • All sterilization processes do not changed the hydrophilicity of PLA. • Morphological, chemical, physical and thermal changes were observed for the PLA SSS . • The sterilization by saturated steam is not recommended to sterilize PLA.

  18. Quality Control for Expanded Tsetse Production, Sterilization and Field Application

    International Nuclear Information System (INIS)

    2012-07-01

    The use of the sterile insect technique (SIT) for the control of pest insects as part of an integrated, area-wide approach is widely accepted. Its application for the eradication of different tsetse flies, the vectors of human sleeping sickness and African animal trypanosomosis, is attracting increasing interest. Following several initial demonstrations of the application of the SIT for tsetse control the technique was applied on the island of Unguja, Zanzibar, in the mid-1990s and, as the final component of an integrated control programme, led to the eradication of the only tsetse species on the island, Glossina austeni. This successful programme encouraged a number of countries to embark on projects with an SIT component for tsetse control, most Ethiopia. In 2001 the Pan African Tsetse and Trypanosomosis Eradication Campaign (PATTEC) was launched by the Organization of African Unity (now African Union, AU) and, subsequently, six countries obtained funding from the African Development Bank (AfDB) in 2005 to support control programmes with an SIT component. A further six countries have subsequently requested AfDB funding for their programmes. The FAO/IAEA coordinated research project (CRP) on Automation for Tsetse Mass Rearing For Use in Sterile Insect Technique Programmes, which was completed in 2001, led to the development of a semi-automated system for tsetse production. Using this new system, a large rearing facility was established in Addis Ababa, Ethiopia, to supply sterile males for an elimination programme in the southern Rift Valley. The development of large-scale rearing highlighted the need for improved quality control procedures and, with this in mind, the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture established a CRP in 2003 entitled Improved and Harmonized Quality Control for Expanded Tsetse Production, Sterilization and Field Application with the Objective of Improving and Expanding the Quality Control Sections of the FAO

  19. Quality Control for Expanded Tsetse Production, Sterilization and Field Application

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-15

    The use of the sterile insect technique (SIT) for the control of pest insects as part of an integrated, area-wide approach is widely accepted. Its application for the eradication of different tsetse flies, the vectors of human sleeping sickness and African animal trypanosomosis, is attracting increasing interest. Following several initial demonstrations of the application of the SIT for tsetse control the technique was applied on the island of Unguja, Zanzibar, in the mid-1990s and, as the final component of an integrated control programme, led to the eradication of the only tsetse species on the island, Glossina austeni. This successful programme encouraged a number of countries to embark on projects with an SIT component for tsetse control, most Ethiopia. In 2001 the Pan African Tsetse and Trypanosomosis Eradication Campaign (PATTEC) was launched by the Organization of African Unity (now African Union, AU) and, subsequently, six countries obtained funding from the African Development Bank (AfDB) in 2005 to support control programmes with an SIT component. A further six countries have subsequently requested AfDB funding for their programmes. The FAO/IAEA coordinated research project (CRP) on Automation for Tsetse Mass Rearing For Use in Sterile Insect Technique Programmes, which was completed in 2001, led to the development of a semi-automated system for tsetse production. Using this new system, a large rearing facility was established in Addis Ababa, Ethiopia, to supply sterile males for an elimination programme in the southern Rift Valley. The development of large-scale rearing highlighted the need for improved quality control procedures and, with this in mind, the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture established a CRP in 2003 entitled Improved and Harmonized Quality Control for Expanded Tsetse Production, Sterilization and Field Application with the Objective of Improving and Expanding the Quality Control Sections of the FAO

  20. Sterility and meeting competitiveness of medfly, Ceratitis Capitata (Wiedemann)

    International Nuclear Information System (INIS)

    Taein-Tun; Molly-Maung-Maung

    2001-01-01

    The basic methodology in the determination of sterilising dosage in male med flies and mating competitiveness with the normal males was carried out in the laboratory. Application of the Sterile Insect Technique (S.I.T.) by three irradiation dosages on Seib-6096 pupae results in sterility when dosage increased. A lower mating competitiveness was observed with the increase in sterility value. This value was determined from the corrected egg hatch percent. The resulting data showed that irradiation dosage of γ 10.0 Krad gave a good advantage to suppress the population in the next generation. The method suggested a good application in the control and eradication of fruit flies. (author)

  1. Implication of sterile fermions in particle physics and cosmology

    International Nuclear Information System (INIS)

    Lucente, M.

    2015-01-01

    The Ph.D. thesis work summarised in this manuscript was dedicated to studying several aspects of the phenomenology of Standard Model (SM) extensions by sterile fermions, in particular their impact for particle and astro-particle physics. An important part of the work is dedicated to a class of SM extensions which allow to explain the smallness of the observed neutrino masses (as well as their mixings) by linking them to the breaking of total lepton number, in the framework of the so-called Inverse seesaw mechanism (ISS). The work described in the thesis addresses the role of these sterile states in providing a satisfactory explanation to 3 open observational problems of the SM: the generation of neutrino masses and mixings, a viable dark matter candidate, and the dynamical generation of the baryon asymmetry of the Universe. We identified the minimal ISS realisation accounting for the observed neutrino data while at the same time complying with all available experimental and observational constraints. This study was based on a perturbative approach to the diagonalization of the neutrino mass matrix, which allowed to identify the number of states associated with the different mass scales. Our study revealed that, depending on the number of additional sterile fermion fields, the ISS can accommodate both a 3-flavour mixing scheme and a 3+more mixing scheme. The potential role of these sterile states as dark matter (DM) candidates led us to carry a dedicated study of the viability of the sterile fermion dark matter hypothesis in a minimal ISS realisation (in which the SM is extended by 2 right-handed neutrinos and 3 additional sterile fermion fields). The degeneracy in the sterile neutrino mass spectrum - which is characteristic of low scale seesaw models with approximate lepton number conservation - can play a relevant role in cosmology, since it allows us to explain the observed baryon asymmetry of the Universe via lepto-genesis. We identified different lepton number

  2. Comparison of Sterile and Clean Dressing Techniques in Post ...

    African Journals Online (AJOL)

    Comparison of Sterile and Clean Dressing Techniques in Post-operative Surgical Wound Infection in a Chinese Healthcare Facility. ... of sterile and clean dressing techniques on wound management in a Chinese hospital, and to compare their impact on wound healing and the cost of the dressing materials with respect to ...

  3. The influence of sterilization on nitrogen-included ultrananocrystalline diamond for biomedical applications.

    Science.gov (United States)

    Tong, Wei; Tran, Phong A; Turnley, Ann M; Aramesh, Morteza; Prawer, Steven; Brandt, Milan; Fox, Kate

    2016-04-01

    Diamond has shown great potential in different biomedical applications, but the effects of sterilization on its properties have not been investigated. Here, we studied the influence of five sterilization techniques (solvent cleaning, oxygen plasma, UV irradiation, autoclave and hydrogen peroxide) on nitrogen-included ultrananocrystalline diamond. The chemical modification of the diamond surface was evaluated using X-ray photoelectron spectroscopy and water contact angle measurements. Different degrees of surface oxidation and selective sp(2) bonded carbon etching were found following all sterilization techniques, resulting in an increase of hydrophilicity. Higher viabilities of in vitro mouse 3T3 fibroblasts and rat cortical neuron cells were observed on oxygen plasma, autoclave and hydrogen peroxide sterilized diamond, which correlated with their higher hydrophilicity. By examination of apatite formation in simulated body fluid, in vivo bioactivity was predicted to be best on those surfaces which have been oxygen plasma treated and lowest on those which have been exposed to UV irradiation. The charge injection properties were also altered by the sterilization process and there appears to be a correlation between these changes and the degree of oxygen termination of the surface. We find that the modification brought by autoclave, oxygen plasma and hydrogen peroxide were most consistent with the use of N-UNCD in biological applications as compared to samples sterilized by solvent cleaning or UV exposure or indeed non-sterilized. A two-step process of sterilization by hydrogen peroxide following oxygen plasma treatment was then suggested. However, the final choice of sterilization technique will depend on the intended end application. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Search for Sterile Neutrinos Using the MiniBooNE Beam

    Energy Technology Data Exchange (ETDEWEB)

    Sorel, Michel [Columbia Univ., New York, NY (United States)

    2005-01-01

    The possible existence of light sterile neutrinos in Nature is motivated, and the prospects to extend sterile neutrino searches beyond current limits is substantiated, using the MiniBooNE neutrino beam and detector at Fermilab. We report on the neutrino flux predictions for the MiniBooNE experiment, on the characterization of the charged-current, quasi-elastic interactions of muon neutrinos ({nu}{sub {mu}}n {yields} {mu}{sup -}p) observed, and on the experiment's sensitivity to sterile neutrinos via muon neutrino disappearance.

  5. Homestake result, sterile neutrinos, and low energy solar neutrino experiments

    Science.gov (United States)

    de Holanda, P. C.; Smirnov, A. Yu.

    2004-06-01

    The Homestake result is about ˜2σ lower than the Ar-production rate, QAr, predicted by the large mixing angle (LMA) Mikheyev-Smirnov-Wolfenstein solution of the solar neutrino problem. Also there is no apparent upturn of the energy spectrum (R≡Nobs/NSSM) at low energies in SNO and Super-Kamiokande. Both these facts can be explained if a light, Δm201˜(0.2 2)×10-5 eV2, sterile neutrino exists which mixes very weakly with active neutrinos: sin2 2α˜(10-5 10-3). We perform both the analytical and numerical study of the conversion effects in the system of two active neutrinos with the LMA parameters and one weakly mixed sterile neutrino. The presence of sterile neutrino leads to a dip in the survival probability in the intermediate energy range E=(0.5 5) MeV thus suppressing the Be, or/and pep, CNO, as well as B electron neutrino fluxes. Apart from diminishing QAr it leads to decrease of the Ge-production rate and may lead to the decrease of the BOREXINO signal as well as the CC/NC ratio at SNO. Future studies of the solar neutrinos by SNO, SK, BOREXINO, and KamLAND as well as by the new low energy experiments will allow us to check this possibility.

  6. Genetic architecture of hybrid male sterility in Drosophila: analysis of intraspecies variation for interspecies isolation.

    Directory of Open Access Journals (Sweden)

    Laura K Reed

    Full Text Available BACKGROUND: The genetic basis of postzygotic isolation is a central puzzle in evolutionary biology. Evolutionary forces causing hybrid sterility or inviability act on the responsible genes while they still are polymorphic, thus we have to study these traits as they arise, before isolation is complete. METHODOLOGY/PRINCIPAL FINDINGS: Isofemale strains of D. mojavensis vary significantly in their production of sterile F(1 sons when females are crossed to D. arizonae males. We took advantage of the intraspecific polymorphism, in a novel design, to perform quantitative trait locus (QTL mapping analyses directly on F(1 hybrid male sterility itself. We found that the genetic architecture of the polymorphism for hybrid male sterility (HMS in the F(1 is complex, involving multiple QTL, epistasis, and cytoplasmic effects. CONCLUSIONS/SIGNIFICANCE: The role of extensive intraspecific polymorphism, multiple QTL, and epistatic interactions in HMS in this young species pair shows that HMS is arising as a complex trait in this system. Directional selection alone would be unlikely to maintain polymorphism at multiple loci, thus we hypothesize that directional selection is unlikely to be the only evolutionary force influencing postzygotic isolation.

  7. Development of atmospheric pressure plasma needle jet for sterilization applications

    Science.gov (United States)

    Elfa, Rizan Rizon; Ahmad, Mohd Khairul; Soon, Chin Fhong; Sahdan, Mohd Zainizan; Lias, Jais; Wibowo, Kusnanto Mukti; Bakar, Ahmad Shuhaimi Abu; Arshad, Mohd Khairuddin Md; Hashim, Uda; Nayan, Nafarizal

    2017-09-01

    Inactivation of bacteria or sterilization has been a major issue in the medical field, especially regarding of human safety, whereby, in a huge scenario fatality can be caused by hazardous bacteria. Often, E-coli as gram-negative bacteria are selected as a key indicator of proper sterilization process as E-coli is tough and dormant bacteria. The technology in sterilization has moved on from chemical, wet and irradiation sterilization to a high promising device such as atmospheric pressure plasma needle jet (APPNJ). It has been reported that atmospheric pressure plasma has provided bundle of advantages over earlier sterilization process. The APPNJ is developed in our lab using high frequency and high voltage neon transformer power supply connected to copper needle and copper sheet electrodes. The gas discharge is Ar gas flowing at 40 L/min through a quartz glass tube. The E-coli bacteria are self-cultured from waste water and then treated with APPNJ. The treatment processes are run into two difference gaps between the plasma orifice and sample with various treatment times. Only 40s is required by direct treatment to achieve 100% killing of E-coli. On the other hand, indirect treatment has inactivated 50% of the E-coli in 40s. In this study, direct and indirect effect of APPNJ to the E-coli can be observed which can be utilized into sterilization of bio-compatible material applications.

  8. Terminal sterilization of equine-derived decellularized tendons for clinical use

    International Nuclear Information System (INIS)

    Pellegata, Alessandro F.; Bottagisio, Marta; Boschetti, Federica; Ferroni, Marco; Bortolin, Monica; Drago, Lorenzo; Lovati, Arianna B.

    2017-01-01

    In the last few years, the demand for tissue substitutes has increased and decellularized matrices has been widely proposed in the medical field to restore severe damages thanks to high biocompatibility and biomechanical properties similar to the native tissues. However, biological grafts represent a potential source of contamination and disease transmission; thus, there is the need to achieve acceptable levels of sterility. Several sterilization methods have been investigated with no consensus on the outcomes in terms of minimizing structural damages and preserving functional features of the decellularized matrix for transplantation in humans. With the aim of making decellularized tendons safe for clinical use, we evaluated the cytocompatibility, and biochemical, structural and biomechanical variations of decellularized equine tendons sterilized with peracetic acid or β-irradiation and differently wet- or dry- stored at 4 °C or − 80 °C, respectively. Considering that both sterilization and long-term storage are crucial steps that could not be avoided, our results pointed at ionizing β-rays as terminal sterilization method for decellularized grafts followed by frozen dry storage. Indeed, this approach can maintain the integrity of collagen-based structures and can avoid biomechanical changes, thus making xenogeneic decellularized tendons a promising candidate for clinical use. - Highlights: • A decellularized tendon matrix has been generated. • The sterility of the decellularized matrix is mandatory for transplantation. • β-irradiation and cold storage preserve the matrix structure and biomechanics.

  9. Terminal sterilization of equine-derived decellularized tendons for clinical use

    Energy Technology Data Exchange (ETDEWEB)

    Pellegata, Alessandro F. [Department of Chemistry, Materials and Chemical Engineering Giulio Natta, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan (Italy); Bottagisio, Marta [Cell and Tissue Engineering Laboratory, IRCCS Galeazzi Orthopaedic Institute, Via Riccardo Galeazzi 4, 20161 Milan (Italy); Boschetti, Federica; Ferroni, Marco [Department of Chemistry, Materials and Chemical Engineering Giulio Natta, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milan (Italy); Bortolin, Monica [Laboratory of Clinical Chemistry and Microbiology, IRCCS Galeazzi Orthopaedic Institute, Via Riccardo Galeazzi 4, 20161 Milan (Italy); Drago, Lorenzo [Laboratory of Clinical Chemistry and Microbiology, IRCCS Galeazzi Orthopaedic Institute, Via Riccardo Galeazzi 4, 20161 Milan (Italy); Department of Biomedical Science for Health, University of Milan, via Luigi Mangiagalli 31, 20133 Milan (Italy); Lovati, Arianna B., E-mail: arianna.lovati@grupposandonato.it [Cell and Tissue Engineering Laboratory, IRCCS Galeazzi Orthopaedic Institute, Via Riccardo Galeazzi 4, 20161 Milan (Italy)

    2017-06-01

    In the last few years, the demand for tissue substitutes has increased and decellularized matrices has been widely proposed in the medical field to restore severe damages thanks to high biocompatibility and biomechanical properties similar to the native tissues. However, biological grafts represent a potential source of contamination and disease transmission; thus, there is the need to achieve acceptable levels of sterility. Several sterilization methods have been investigated with no consensus on the outcomes in terms of minimizing structural damages and preserving functional features of the decellularized matrix for transplantation in humans. With the aim of making decellularized tendons safe for clinical use, we evaluated the cytocompatibility, and biochemical, structural and biomechanical variations of decellularized equine tendons sterilized with peracetic acid or β-irradiation and differently wet- or dry- stored at 4 °C or − 80 °C, respectively. Considering that both sterilization and long-term storage are crucial steps that could not be avoided, our results pointed at ionizing β-rays as terminal sterilization method for decellularized grafts followed by frozen dry storage. Indeed, this approach can maintain the integrity of collagen-based structures and can avoid biomechanical changes, thus making xenogeneic decellularized tendons a promising candidate for clinical use. - Highlights: • A decellularized tendon matrix has been generated. • The sterility of the decellularized matrix is mandatory for transplantation. • β-irradiation and cold storage preserve the matrix structure and biomechanics.

  10. Contraception or eugenics? Sterilization and "mental retardation" in the 1970s and 1980s.

    Science.gov (United States)

    Ladd-Taylor, Molly

    2014-01-01

    Nonconsensual sterilization is usually seen as the by-product of a classist and racist society; disability is ignored. This article examines the 1973 sterilization of two young black girls from Alabama and other precedent-setting court cases involving the sterilization of "mentally retarded" white women to make disability more central to the historical analysis of sterilization. It analyzes the concept of mental retardation and the appeal of a surgical solution to birth control, assesses judicial deliberations over the "right to choose" contraceptive sterilization when the capacity to consent is in doubt, and reflects on the shadow of eugenics that hung over the sterilization debate in the 1970s and 1980s.

  11. Efficacy of gamma sterilization technique for biofertilizer carrier production

    International Nuclear Information System (INIS)

    Rallos, Roland V.; Rivera, Faye G.; Anarna, Julie A.; Rojales, Jacqueline S.

    2013-01-01

    Th use of gamma irradiation as sterilization technique for biofertilizer carrier is very efficient and practical especially in large scale production. The results of this study on the efficacy of gamma sterilization justify research on the effects of established doses of gamma irradiation on the physico-chemical properties of the clay-charcoal mixture

  12. Pharmaceutical aerosols. Study of their gamma radiation sterilization

    International Nuclear Information System (INIS)

    Sebert, P.

    1984-10-01

    The gamma radiation sterilization of pharmaceutical aerosols was studied. The following topics were investigated: radiosterilization of nitrogen protoxide used as a propellant; radiosterilization of packaging materials (aluminium containers, plastics valves); radio-sterilization of excipients and active ingredients. Most of the investigated materials proved to be stable to irradiation (2,5 Mrads) from pharmacopoeial aspect. Stability tests of the preparations packaged showed no change in the parameters investigated [fr

  13. Update application and development of radiation sterilization technology on pharmacy eutical industry

    International Nuclear Information System (INIS)

    Zhao Yongfu; Nanjing Univ., Nanjing; Wang Changbao; Wang Chao

    2006-01-01

    Since 'Standard of Radiation Sterilization by 60 Co Irradiator on Chinese Medicine' has been cleared, radiation sterilization technology obtains the widespread application on pharmacy. In this paper, the newest application and development of this technology on pharmacy are introduced from several aspects, such as dose control, drugs packing, the influence of radiation on functional ingredients and so on. Aimed at the current problem of radiation sterilization on pharmacy of our country, concrete measure is proposed. And the application of radiation sterilization on health food, enzyme preparation and controlled-release capsule is specially introduced. (authors)

  14. Hybrid male sterility and genome-wide misexpression of male reproductive proteases

    OpenAIRE

    Gomes, Suzanne; Civetta, Alberto

    2015-01-01

    Hybrid male sterility is a common barrier to gene flow between species. Previous studies have posited a link between misregulation of spermatogenesis genes in interspecies hybrids and sterility. However, in the absence of fully fertile control hybrids, it is impossible to differentiate between misregulation associated with sterility vs. fast male gene regulatory evolution. Here, we differentiate between these two possibilities using a D. pseudoobscura species pair that experiences unidirectio...

  15. Studies on the ecology of insects sterilized artificially (gamma radiation), 8

    International Nuclear Information System (INIS)

    Kiyoku, Masao; Tsukuda, Ritsuko

    1974-01-01

    Gamma-ray irradiation of 7 KR from 137 Cs on the oriental fruit fly pupae two days before emerging did not significantly reduce the percentage of emergence and longevity of adult flies. However, highly sterile adults (more than 98.9%) were found in those combinations, S#male# x N#female#, N#male# x S#female# and S#male# x S#female#. The result of observation of sperm activity in spermathecae of females mated with sterilized males showed that the sterility is caused by dominant lethalities. The sexual competitiveness between S#male# and N#male# has been examined in experiments of S#male# x N#male# x N#female#. (1) The data suggest that the sterility percentage concerning with egg hatchability is proportional to the rate of sterilized males replaced for normal males when that is expressed with a multiple of the ratio of normal males to normal females. Seven such straight lines thus obtained made us possible to find the theoretical expectation of sterility percentage. (2) Relationship between the percent egg hatch observed (y), or that estimated theoretically (Y), and logarithm of ratio, S#male#/N#male# (x) was showed to be two straight regression equations, y=18.413-11.952 (x - 1.295) and Y=11.890-15.462 (x - 1.295). Ratio of regression coefficients of the equations was 0.772. (3) Correlations between the sterility percentage and ratio, S#male#/N#male#, showed in three convex curves under three degrees of competitiveness (0.265, 0.576 and 1.001). When both the values of S#male#/N#male# in the mating experiments and the sterility percentages are given, it is possible to obtain degrees of competitiveness using the curves. (auth.)

  16. Search for heavy sterile neutrinos in trileptons at the LHC

    International Nuclear Information System (INIS)

    Dib, Claudio O.; Kim, C.S.; Wang, Kechen; Chinese Academy of Sciences, Beijing

    2017-03-01

    We present a search strategy for both Dirac and Majorana sterile neutrinos from the purely leptonic decays of W"±→e"±e"±μ"-"+ν and μ"±μ"±e"-"+ν at the 14 TeV LHC. The discovery and exclusion limits for sterile neutrinos are shown using both the Cut-and-Count (CC) and Multi-Variate Analysis (MVA) methods. We also discriminate between Dirac and Majorana sterile neutrinos by exploiting a set of kinematic observables which differ between the Dirac and Majorana cases. We find that the MVA method, compared to the more common CC method, can greatly enhance the discovery and discrimination limits. Two benchmark points with sterile neutrino mass m_N=20 GeV and 50 GeV are tested. For an integrated luminosity of 3000 fb"-"1, sterile neutrinos can be found with 5σ significance if heavy-to-light neutrino mixings vertical stroke U_N_e vertical stroke "2∝ vertical stroke U_N_μ vertical stroke "2∝10"-"6, while Majorana vs. Dirac discrimination can be reached if at least one of the mixings is of order 10"-"5.

  17. Utilization of male sterility in forage crops

    International Nuclear Information System (INIS)

    Suginobu, Ken-ichi

    1982-01-01

    The genetic nature of male sterility in forage crops was reviewed. Many workers have suggested that hybrids in forage crops are quite promising. First, the selection of the most desirable parental genotype from a large original population is improtant in heterosis breeding programs. After the more promising inbreds or clones have been selected on the basis of good general combining ability, it is necessary to identify the particular single, three-way or double cross that will produce the highest yields. A high seed yield potential is also important in a new variety so that the seeds can be sold at lower prices than other varieties. A tentative scheme for hybrid seed production by using inbred lines of male sterile or normal parents is proposed. At a breeding station, the seeds for male sterile F 1 (AB), maintainer S 1 (C-S 1 ) and either maintainer or restorer S 1 s(D-S 1 , E-S 1 ) are produced from the parental clones. At a seed increase agency, the seeds for male sterile F 1 (ABC) and either maintainer or restorer S 2 (D-S 2 ) are produced. In the case that D-S 2 seed production is difficult, maintainer or restorer F 1 (DE) should be produced from D-S 1 x E-S 1 . These seeds are used for commercial seed production. Seeds of hybrid F 1 (ABCD) or hybrid F 1 (ABCDE) are for practical use. (Kaihara, S.)

  18. Sterilization validation for medical compresses at IRASM multipurpose irradiation facility

    International Nuclear Information System (INIS)

    Alexandru, Mioara; Ene, Mihaela

    2007-01-01

    In Romania, IRASM Radiation Processing Center is the unique supplier of radiation sterilization services-industrial scale (ISO 9001:2000 and ISO 13485:2003 certified). Its Laboratory of Microbiological Testing is the sole third party competent laboratory (GLPractice License, ISO 17025 certification in progress) for pharmaceutics and medical devices as well. We here refer to medical compresses as a distinct category of sterile products, made from different kind of hydrophilic materials (cotton, non-woven, polyurethane foam) with or without an impregnated ointment base (paraffin, plant extracts). These products are included in the class of medical devices, but for the sterilization validation, from microbiological point of view, there are important differences in testing method compared to the common medical devices (syringes, catheters, etc). In this paper, we present some results and practical solutions chosen to perform a sterilization validation, compliant with ISO 11137: 2006

  19. Sterile neutrinos and indirect dark matter searches in IceCube

    Science.gov (United States)

    Argüelles, Carlos A.; Kopp, Joachim

    2012-07-01

    If light sterile neutrinos exist and mix with the active neutrino flavors, this mixing will affect the propagation of high-energy neutrinos from dark matter annihilation in the Sun. In particular, new Mikheyev-Smirnov-Wolfenstein resonances can occur, leading to almost complete conversion of some active neutrino flavors into sterile states. We demonstrate how this can weaken IceCube limits on neutrino capture and annihilation in the Sun and how potential future conflicts between IceCube constraints and direct detection or collider data might be resolved by invoking sterile neutrinos. We also point out that, if the dark matter-nucleon scattering cross section and the allowed annihilation channels are precisely measured in direct detection and collider experiments in the future, IceCube can be used to constrain sterile neutrino models using neutrinos from the dark matter annihilation.

  20. Effects of sterilization treatments on the analysis of TOC in water samples.

    Science.gov (United States)

    Shi, Yiming; Xu, Lingfeng; Gong, Dongqin; Lu, Jun

    2010-01-01

    Decomposition experiments conducted with and without microbial processes are commonly used to study the effects of environmental microorganisms on the degradation of organic pollutants. However, the effects of biological pretreatment (sterilization) on organic matter often have a negative impact on such experiments. Based on the principle of water total organic carbon (TOC) analysis, the effects of physical sterilization treatments on determination of TOC and other water quality parameters were investigated. The results revealed that two conventional physical sterilization treatments, autoclaving and 60Co gamma-radiation sterilization, led to the direct decomposition of some organic pollutants, resulting in remarkable errors in the analysis of TOC in water samples. Furthermore, the extent of the errors varied with the intensity and the duration of sterilization treatments. Accordingly, a novel sterilization method for water samples, 0.45 microm micro-filtration coupled with ultraviolet radiation (MCUR), was developed in the present study. The results indicated that the MCUR method was capable of exerting a high bactericidal effect on the water sample while significantly decreasing the negative impact on the analysis of TOC and other water quality parameters. Before and after sterilization treatments, the relative errors of TOC determination could be controlled to lower than 3% for water samples with different categories and concentrations of organic pollutants by using MCUR.