WorldWideScience

Sample records for continuous positive airway pressure

  1. Continuous Positive Airway Pressure (CPAP)

    Science.gov (United States)

    ... ENT Doctor Near You Continuous Positive Airway Pressure (CPAP) Continuous Positive Airway Pressure (CPAP) Patient Health Information ... relations staff at newsroom@entnet.org . What Is CPAP? The most common and effective nonsurgical treatment for ...

  2. The importance of clinical monitoring for compliance with Continuous Positive Airway Pressure.

    Science.gov (United States)

    Pelosi, Lucas B; Silveira, Mariana L C; Eckeli, Alan L; Chayamiti, Emilia M P C; Almeida, Leila A; Sander, Heidi H; Küpper, Daniel S; Valera, Fabiana C P

    Obstructive sleep apnea syndrome is currently a public health problem of great importance. When misdiagnosed or improperly treated, it can lead to serious consequences on patients' quality of life. The gold standard treatment for cases of obstructive sleep apnea syndrome, especially in mild to severe and symptomatic cases, is continuous positive airway pressure therapy. Compliance with continuous positive airway pressure therapy is directly dependent on the active participation of the patient, which can be influenced by several factors. The objective of this study is to describe the factors related to compliance with continuous positive airway pressure therapy, and to analyze which associated factors directly influence the efficiency of the treatment. Patients who received continuous positive airway pressure therapy through the Municipal Health Department of the city of Ribeirão Preto were recruited. A structured questionnaire was administered to the patients. Compliance with continuous positive airway pressure therapy was assessed by average hours of continuous positive airway pressure therapy usage per night. Patients with good compliance (patients using continuous positive airway pressure therapy ≥4h/night) were compared to those with poor compliance (patients using <4h/night). 138 patients were analyzed: 77 (55.8%) were considered compliant while 61 (44.2%) were non-compliant. The comparison between the two groups showed that regular monitoring by a specialist considerably improved compliance with continuous positive airway pressure therapy (odds ratio, OR=2.62). Compliance with continuous positive airway pressure therapy is related to educational components, which can be enhanced with continuous and individualized care to patients with obstructive sleep apnea syndrome. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  3. Improvised bubble continuous positive airway pressure (BCPAP ...

    African Journals Online (AJOL)

    Improvised bubble continuous positive airway pressure (BCPAP) device at the National Hospital Abuja gives immediate improvement in respiratory rate and oxygenation in neonates with respiratory distress.

  4. Improvised bubble continuous positive airway pressure

    African Journals Online (AJOL)

    PROF. EZECHUKWU

    2014-08-15

    Aug 15, 2014 ... Abstract: Background: Prematur- ity accounts for 25% of Neonatal mortality in Nigeria and Respira- tory Distress Syndrome is respon- sible for half of these deaths. Introducing continuous positive airway pressure for the treatment of RDS in Nigeria where health care financing is predominantly out-of-pocket ...

  5. Comparison of Efficacy and Tolerance of Automatic Continuous Positive Airway Pressure Devices With the Optimum Continuous Positive Airway Pressure.

    Science.gov (United States)

    Tommi, George; Aronow, Wilbert S; Sheehan, John C; McCleay, Matthew T; Meyers, Patrick G

    Patients diagnosed with obstructive sleep apnea syndrome were randomly placed on automatic continuous positive airway pressure (ACPAP) for 2 hours followed by manual titration for the rest of the night. One hundred sixty-one patients entered the study, with at least 50 patients titrated with each of 3 ACPAP devices. The optimum continuous positive airway pressure (CPAP) was defined as the lowest pressure with an apnea-hypoxia index of ≤5/hr, which ranged from 4 cm to 18 cm. Success with ACPAP was approximately 60%-80% when the optimum CPAP was 4-6 cm but fell to below 30% if the optimum CPAP was ≥8 cm (P = 0.001). Average ACPAP ranged from 2 to 10 cm below the optimum level if the optimum CPAP was ≥8 cm. Patients who responded to a low CPAP but deteriorated on higher pressures failed to respond to any of the automatic devices. We recommend that CPAP titration be performed manually before initiation of ACPAP in patients with obstructive sleep apnea. The basal pressure for ACPAP should be the optimum pressure obtained by manual titration. Limits on the upper level of ACPAP may be necessary for patients who deteriorate on higher positive pressures.

  6. Continuous positive airway pressure therapy: new generations.

    LENUS (Irish Health Repository)

    Garvey, John F

    2010-02-01

    Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS). However, CPAP is not tolerated by all patients with OSAS and alternative modes of pressure delivery have been developed to overcome pressure intolerance, thereby improving patient comfort and adherence. Auto-adjustable positive airway pressure (APAP) devices may be utilised for the long-term management of OSAS and may also assist in the initial diagnosis of OSAS and titration of conventional CPAP therapy. Newer modalities such as C-Flex and A-Flex also show promise as treatment options in the future. However, the evidence supporting the use of these alternative modalities remains scant, in particular with regard to long-term cardiovascular outcomes. In addition, not all APAP devices use the same technological algorithms and data supporting individual APAP devices cannot be extrapolated to support all. Further studies are required to validate the roles of APAP, C-Flex and A-Flex. In the interim, standard CPAP therapy should continue as the mainstay of OSAS management.

  7. Continuous positive airway pressure therapy: new generations.

    LENUS (Irish Health Repository)

    Garvey, John F

    2012-02-01

    Continuous positive airway pressure (CPAP) is the treatment of choice for obstructive sleep apnoea syndrome (OSAS). However, CPAP is not tolerated by all patients with OSAS and alternative modes of pressure delivery have been developed to overcome pressure intolerance, thereby improving patient comfort and adherence. Auto-adjustable positive airway pressure (APAP) devices may be utilised for the long-term management of OSAS and may also assist in the initial diagnosis of OSAS and titration of conventional CPAP therapy. Newer modalities such as C-Flex and A-Flex also show promise as treatment options in the future. However, the evidence supporting the use of these alternative modalities remains scant, in particular with regard to long-term cardiovascular outcomes. In addition, not all APAP devices use the same technological algorithms and data supporting individual APAP devices cannot be extrapolated to support all. Further studies are required to validate the roles of APAP, C-Flex and A-Flex. In the interim, standard CPAP therapy should continue as the mainstay of OSAS management.

  8. Nasal continuous positive airway pressure

    DEFF Research Database (Denmark)

    Scholze, Alexandra; Lamwers, Stephanie; Tepel, Martin

    2012-01-01

    Obstructive sleep apnoea (OSA) is linked to increased cardiovascular risk. This risk can be reduced by nasal continuous positive airway pressure (nCPAP) treatment. As OSA is associated with an increase of several vasoconstrictive factors, we investigated whether nCPAP influences the digital volume...... pulse wave. We performed digital photoplethysmography during sleep at night in 94 consecutive patients who underwent polysomnography and 29 patients treated with nCPAP. Digital volume pulse waves were obtained independently of an investigator and were quantified using an algorithm for continuous.......01; n = 94) and the arousal index (Spearman correlation, r = 0.21; p CPAP treatment, the AHI was significantly reduced from 27 ± 3 events · h(-1) to 4 ± 2 events · h(-1) (each n = 29; p

  9. Extubation success in premature infants with respiratory distress syndrome treated with bi-level nasal continuous positive airway pressure versus nasal intermittent positive pressure ventilation.

    Science.gov (United States)

    Thomas, Patricia E; LeFlore, Judy

    2013-01-01

    Infants born prematurely with respiratory distress syndrome are at high risk for complications from mechanical ventilation. Strategies are needed to minimize their days on the ventilator. The purpose of this study was to compare extubation success rates in infants treated with 2 different types of continuous positive airway pressure devices. A retrospective cohort study design was used. Data were retrieved from electronic medical records for patients in a large, metropolitan, level III neonatal intensive care unit. A sample of 194 premature infants with respiratory distress syndrome was selected, 124 of whom were treated with nasal intermittent positive pressure ventilation and 70 with bi-level variable flow nasal continuous positive airway pressure (bi-level nasal continuous positive airway pressure). Infants in both groups had high extubation success rates (79% of nasal intermittent positive pressure ventilation group and 77% of bi-level nasal continuous positive airway pressure group). Although infants in the bi-level nasal continuous positive airway pressure group were extubated sooner, there was no difference in duration of oxygen therapy between the 2 groups. Promoting early extubation and extubation success is a vital strategy to reduce complications of mechanical ventilation that adversely affect premature infants with respiratory distress syndrome.

  10. Duration of continuous positive airway pressure in premature infants

    OpenAIRE

    Bamat, Nicolas; Jensen, Erik A.; Kirpalani, Haresh

    2016-01-01

    Continuous positive airway pressure (CPAP) has been used for respiratory support in premature infants for more than 40 years and is now a cornerstone of modern neonatal care. Clinical research on CPAP has primarily focused on understanding which devices and pressure sources best implement this therapy. In contrast, less research has examined the optimal duration over which CPAP is administered. We review this aspect of CPAP therapy.

  11. Continuous Positive Airway Pressure Strategies with Bubble Nasal Continuous Positive Airway Pressure: Not All Bubbling Is the Same: The Seattle Positive Airway Pressure System.

    Science.gov (United States)

    Welty, Stephen E

    2016-12-01

    Premature neonates are predisposed to complications, including bronchopulmonary dysplasia (BPD). BPD is associated with long-term pulmonary and neurodevelopmental consequences. Noninvasive respiratory support with nasal continuous positive airway pressure (CPAP) has been recommended strongly by the American Academy of Pediatrics. However, CPAP implementation has shown at least a 50% failure rate. Enhancing nasal CPAP effectiveness may decrease the need for mechanical ventilation and reduce the incidence of BPD. Bubble nasal CPAP is better than nasal CPAP using mechanical devices and the bubbling provides air exchange in distal respiratory units. The Seattle PAP system reduces parameters that assess work of breathing. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Duration of continuous positive airway pressure in premature infants

    Science.gov (United States)

    Bamat, Nicolas; Jensen, Erik A.; Kirpalani, Haresh

    2016-01-01

    SUMMARY Continuous positive airway pressure (CPAP) has been used for respiratory support in premature infants for more than 40 years and is now a cornerstone of modern neonatal care. Clinical research on CPAP has primarily focused on understanding which devices and pressure sources best implement this therapy. In contrast, less research has examined the optimal duration over which CPAP is administered. We review this aspect of CPAP therapy. PMID:26948885

  13. Increased airway reactivity in a neonatal mouse model of Continuous Positive Airway Pressure (CPAP)

    OpenAIRE

    Mayer, Catherine A.; Martin, Richard J.; MacFarlane, Peter M.

    2015-01-01

    Background Continuous positive airway pressure (CPAP) is a primary form of respiratory support used in the intensive care of preterm infants, but its long-term effects on airway (AW) function are unknown. Methods We developed a neonatal mouse model of CPAP treatment to determine whether it modifies later AW reactivity. Un-anesthetized spontaneously breathing mice were fitted with a mask to deliver CPAP (6cmH2O, 3hrs/day) for 7 consecutive days starting at postnatal day 1. Airway reactivity to...

  14. Early nasal continuous positive airway pressure in a cohort of the smallest infants in Denmark

    DEFF Research Database (Denmark)

    Hansen, Bo M; Esbjørn, Barbara Hoff; Greisen, G

    2004-01-01

    To evaluate neurodevelopmental outcome at age 5 y of age in a cohort of preterm children treated mainly with nasal continuous positive airway pressure (CPAP) in the neonatal period.......To evaluate neurodevelopmental outcome at age 5 y of age in a cohort of preterm children treated mainly with nasal continuous positive airway pressure (CPAP) in the neonatal period....

  15. Boussignac continuous positive airway pressure for weaning with tracheostomy tubes

    NARCIS (Netherlands)

    Dieperink, Willem; Aarts, Leon P. H. J.; Rodgers, Michael G. G.; Delwig, Hans; Nijsten, Maarten W. N.

    2008-01-01

    Background: In patients who are weaned with a tracheostomy tube ( TT), continuous positive airway pressure ( CPAP) is frequently used. Dedicated CPAP systems or ventilators with bulky tubing are usually applied. However, CPAP can also be effective without a ventilator by the disposable Bous-signac

  16. Effect of nasal continuous and biphasic positive airway pressure on lung volume in preterm infants

    NARCIS (Netherlands)

    Miedema, Martijn; van der Burg, Pauline S.; Beuger, Sabine; de Jongh, Frans H.; Frerichs, Inez; van Kaam, Anton H.

    2013-01-01

    To monitor regional changes in end-expiratory lung volume (EELV), tidal volumes, and their ventilation distribution during different levels of nasal continuous positive airway pressure (nCPAP) and nasal biphasic positive airway pressure (BiPAP) in stable preterm infants. By using electrical

  17. Multiple applications of the Boussignac continuous positive airway pressure system

    NARCIS (Netherlands)

    Dieperink, Willem

    2008-01-01

    Continuous positive airway pressure, (CPAP) is a form of treatment to support patients with dyspnea. For the application of CPAP a mechanical ventilator or complex CPAP apparatus is mostly used. The Boussignac CPAP (BCPAP) system developed by George Boussignac does not need such apparatus. The BCPAP

  18. Continuous positive airway pressure: Physiology and comparison of devices.

    Science.gov (United States)

    Gupta, Samir; Donn, Steven M

    2016-06-01

    Nasal continuous positive airway pressure (CPAP) is increasingly used for respiratory support in preterm babies at birth and after extubation from mechanical ventilation. Various CPAP devices are available for use that can be broadly grouped into continuous flow and variable flow. There are potential physiologic differences between these CPAP systems and the choice of a CPAP device is too often guided by individual expertise and experience rather than by evidence. When interpreting the evidence clinicians should take into account the pressure generation sources, nasal interface, and the factors affecting the delivery of pressure, such as mouth position and respiratory drive. With increasing use of these devices, better monitoring techniques are required to assess the efficacy and early recognition of babies who are failing and in need of escalated support. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Nap-titration : An effective alternative for continuous positive airway pressure titration

    NARCIS (Netherlands)

    Hoekema, A; Stegenga, B; Meinesz, AF; van der Hoeven, JH; Wijkstra, PJ

    When treating Obstructive Steep Apnea-Hypopnea Syndrome (OSAHS) several alternatives for standard (manual) continuous positive airway pressure (CPAP) titration are feasible. A practical alternative is titration without polysomnography during an afternoon nap (Nap-titration). The aim of the present

  20. Nasal continuous positive airway pressure: does bubbling improve gas exchange?

    Science.gov (United States)

    Morley, C J; Lau, R; De Paoli, A; Davis, P G

    2005-07-01

    In a randomised crossover trial, 26 babies, treated with Hudson prong continuous positive airway pressure (CPAP) from a bubbling bottle, received vigorous, high amplitude, or slow bubbling for 30 minutes. Pulse oximetry, transcutaneous carbon dioxide, and respiratory rate were recorded. The bubbling rates had no effect on carbon dioxide, oxygenation, or respiratory rate.

  1. Impact of Polysomnographic Parameters on Continuous Positive Airway Pressure in Patient with Obstructive Sleep Apnea in 2012

    Directory of Open Access Journals (Sweden)

    Abolfazl Mozafari

    2014-06-01

    Full Text Available Background & objectives : O bstructive sleep apnea is a preventable and prevalent major health hazard with serious health consequences including excessive daytime sleepiness, cognitive disturbances, depression, cardiovascular diseases and hypertension. Obstructive sleep apnea is a disorder affecting 2 to 4% of the adult population. The continuous positive airway pressur e (CPAP i s the most efficacious therapy and is often the first option for these patients. The pressure titration during laboratory polysomnography is required for treatment by CPAP.   Methods: The patients with obstructive sleep apnea requiring continuous positive airway pressure treatment were selected . CPAP titration was done according to American Academy of Sleep Medicine protocol. Comparison among continuous positive airway pressure with polysomnographic parameters was performed and analyzed with Pearson correlation coefficient. For analysis of qualitative parameters, we used chi-square and then checked with SPSS version 18 software.   Results: From 125 patients with obstructive sleep apnea, there were 112 cases with inclusion criteria. Mean age of participants was 55.07 ± 12, male frequency was 59.2%, apnea hypopnea index was 43.62 and mean continuous positive airway pressure was 12.50 . There was significant relationship among the pressure of continuous positive airway pressure with apnea hypopnea index (P=0.028, arousal index (P=0.011, body mass index (P=0.041 and O2 desaturation index (P=0.022, although age was not significantly related.   Conclusion: In accordance to this data, we found out a prediction equation for optimal CPAP in our patients

  2. Adherence to continuous positive airway pressure in adults with an intellectual disability

    NARCIS (Netherlands)

    Luijks, K.A.; Vandenbussche, N.L.; Pevernagie, D.; Overeem, S.; Pillen, S.

    STUDY OBJECTIVES: This retrospective study evaluated the feasibility of continuous positive airway pressure (CPAP) therapy in adults with intellectual disabilities (ID). METHODS: CPAP therapy of 24 obstructive sleep apnea syndrome (OSA) patients with ID were compared to age- and sex-matched adults

  3. Bi-level positive airway pressure ventilation for treating heart failure with central sleep apnea that is unresponsive to continuous positive airway pressure.

    Science.gov (United States)

    Dohi, Tomotaka; Kasai, Takatoshi; Narui, Koji; Ishiwata, Sugao; Ohno, Minoru; Yamaguchi, Tetsu; Momomura, Shin-Ichi

    2008-07-01

    Cheyne-Stokes respiration with central sleep apnea (CSR-CSA) is associated with a poor prognosis in patients with heart failure (HF). However, some patients do not respond to continuous positive airway pressure (CPAP), so other therapeutic modalities should be considered, such as bi-level positive airway pressure (PAP), which also assists respiration and might be effective for such patients. The 20 patients with HF because of left ventricular systolic dysfunction were assessed: 8 had ischemic etiology, and all had severe CSA according to the apnea - hypopnea index (AHI) determined by polysomnography. All diagnosed patients underwent repeat polysomnography using CPAP. The AHI improved significantly in 11 (AHI or=15). Bi-level PAP titration significantly improved the AHI in the latter group. Those who were unresponsive to CPAP had significantly lower PaCO(2), higher plasma brain natriuretic peptide (BNP), longer mean duration of CSR and fewer obstructive episodes than CPAP responders. After 6 months of positive airway support with either CPAP (n=9) or bi-level PAP (n=7), BNP levels significantly decreased and left ventricular ejection fraction significantly increased. Bi-level PAP could be an effective alternative for patients with HF and pure CSR-CSA who are unresponsive to CPAP.

  4. Continuous positive airway pressure (CPAP).

    Science.gov (United States)

    Sahni, R; Wung, J T

    1998-01-01

    Progress in neonatal intensive care is closely linked to improvements in the management of respiratory failure in small infants. This applies to the care of the preterm infants with immature lungs, and also to treatment of the preterm or full term infants with specific diseases that are associated with respiratory failure. Respiratory distress of the newborn continues to account for significant morbidity in the intensive care unit. The spectrum of disease ranges from mild distress to severe respiratory failure requiring varying degrees of support. The current modalities of ventilatory assistance range from the more benign continuous positive airway pressure (CPAP) to conventional mechanical ventilation, and on to high frequency ventilation. It is a reasonable supposition that the type of ventilatory assistance provided to these infants should be graded according to the severity of the disease. However, the principal objective in selecting the mode of respiratory support should be to use a modality which results in minimal volo- or barotrauma to the infant. The following detailed description on CPAP explains its physiological effects, delivery system, indications for use, application, maintenance, and associated complications. The equipment described is simple to use, has a greater cost benefit, and has a more universal application, which is of help to smaller units including those in the developing parts of the world. We have also included our institutional clinical experience of CPAP usage in very low birth weight infants from the periods before and after commercial availability of surfactant in the United States.

  5. Proportional positive airway pressure: a new concept to treat obstructive sleep apnoea.

    Science.gov (United States)

    Juhász, J; Becker, H; Cassel, W; Rostig, S; Peter, J H

    2001-03-01

    Proportional positive airway pressure (PPAP) was designed to optimize airway pressure for the therapy of obstructive sleep apnoea (OSA). In a randomized crossover prospective study, the clinical feasibility of PPAP and its immediate effects on the breathing disorder and sleep in comparison with continuous positive airway pressure (CPAP) was evaluated. Twelve patients requiring CPAP therapy underwent CPAP and PPAP titration in a random order. Obstructive and mixed respiratory events could be completely abolished with both forms of treatment. This efficacy could be achieved at a significantly lower mean mask pressure during PPAP titration (8.45+/-2.42 cmH2O) compared to CPAP (9.96+/-2.7 cmH2O) (p=0.002). The mean minimal arterial oxygen saturation (Sa,O2) (82.8+/-6.5%) on the diagnostic night increased significantly (pPPAP titration. Total sleep time, slow wave sleep and rapid eye movement (REM) sleep increased significantly by the same amount during both CPAP and PPAP titration (pPPAP titration night, four patients did not have a preference, and two patients preferred CPAP. The present data show that proportional positive airway pressure is as effective as continuous positive airway pressure in eliminating obstructive events and has the same immediate effect on sleep. The lower average mask pressure during proportional positive airway pressure implies potential advantages compared to continuous positive airway pressure. Proportional positive airway pressure presents a new effective therapeutic approach to obstructive sleep apnoea.

  6. Nasal bi-level positive airway pressure (BiPAP) versus nasal continuous positive airway pressure (CPAP) in preterm infants ≤32 weeks: A retrospective cohort study.

    Science.gov (United States)

    Rong, Zhi-Hui; Li, Wen-Bin; Liu, Wei; Cai, Bao-Huan; Wang, Jing; Yang, Min; Li, Wei; Chang, Li-Wen

    2016-05-01

    To investigate whether Bi-level positive airway pressure (BiPAP), compared with nasal continuous positive airway pressure (CPAP), is a more effective therapeutic strategy in preterm infants ≤32 weeks. All inborn infants between 26(+1) and 32(+6) weeks' gestation, admitted to the neonatal intensive care unit (NICU ) of Tongji Medical Hospital between 1 January, 2010 and 31 December, 2011 (the 2010-2011 cohort or CPAP cohort) and between 1 January, 2012 and 31 December, 2013 (the 2012-2013 cohort or BiPAP cohort), were retrospectively identified. The primary outcome was intubation in infants CPAP were subsequently intubated (P CPAP, reduced the need for intubation within the first 72 h of age. © 2016 Paediatrics and Child Health Division (The Royal Australasian College of Physicians).

  7. Influence of upper body position on middle cerebral artery blood velocity during continuous positive airway pressure breathing

    DEFF Research Database (Denmark)

    Højlund Rasmussen, J; Mantoni, T; Belhage, B

    2007-01-01

    Continuous positive airway pressure (CPAP) is a treatment modality for pulmonary oxygenation difficulties. CPAP impairs venous return to the heart and, in turn, affects cerebral blood flow (CBF) and augments cerebral blood volume (CBV). We considered that during CPAP, elevation of the upper body ...

  8. Randomized trial of prongs or mask for nasal continuous positive airway pressure in preterm infants.

    LENUS (Irish Health Repository)

    Kieran, Emily A

    2012-11-01

    To determine whether nasal continuous positive airway pressure (NCPAP) given with nasal prongs compared with nasal mask reduces the rate of intubation and mechanical ventilation in preterm infants within 72 hours of starting therapy.

  9. Reduced local immune response with continuous positive airway pressure during one-lung ventilation for oesophagectomy

    NARCIS (Netherlands)

    Verhage, R. J. J.; Boone, J.; Rijkers, G. T.; Cromheecke, G. J.; Kroese, A. C.; Weijs, T. J.; Borel Rinkes, I. H. M.; van Hillegersberg, R.

    2014-01-01

    Background. Transthoracic oesophagectomy requires prolonged one-lung ventilation causing systemic and local inflammatory responses. Application of continuous positive airway pressure (CPAP) to the collapsed lung potentially reduces pulmonary damage, hypoxia, and consequent inflammation. This

  10. Aerosol delivery and humidification with the Boussignac continuous positive airway pressure device.

    Science.gov (United States)

    Thille, Arnaud W; Bertholon, Jean-François; Becquemin, Marie-Hélène; Roy, Monique; Lyazidi, Aissam; Lellouche, François; Pertusini, Esther; Boussignac, Georges; Maître, Bernard; Brochard, Laurent

    2011-10-01

    A simple method for effective bronchodilator aerosol delivery while administering continuing continuous positive airway pressure (CPAP) would be useful in patients with severe bronchial obstruction. To assess the effectiveness of bronchodilator aerosol delivery during CPAP generated by the Boussignac CPAP system and its optimal humidification system. First we assessed the relationship between flow and pressure generated in the mask with the Boussignac CPAP system. Next we measured the inspired-gas humidity during CPAP, with several humidification strategies, in 9 healthy volunteers. We then measured the bronchodilator aerosol particle size during CPAP, with and without heat-and-moisture exchanger, in a bench study. Finally, in 7 patients with acute respiratory failure and airway obstruction, we measured work of breathing and gas exchange after a β(2)-agonist bronchodilator aerosol (terbutaline) delivered during CPAP or via standard nebulization. Optimal humidity was obtained only with the heat-and-moisture exchanger or heated humidifier. The heat-and-moisture exchanger had no influence on bronchodilator aerosol particle size. Work of breathing decreased similarly after bronchodilator via either standard nebulization or CPAP, but P(aO(2)) increased significantly only after CPAP aerosol delivery. CPAP bronchodilator delivery decreases the work of breathing as effectively as does standard nebulization, but produces a greater oxygenation improvement in patients with airway obstruction. To optimize airway humidification, a heat-and-moisture exchanger could be used with the Boussignac CPAP system, without modifying aerosol delivery.

  11. A new device for administration of continuous positive airway pressure in preterm infants: comparison with a standard nasal CPAP continuous positive airway pressure system.

    Science.gov (United States)

    Trevisanuto, Daniele; Grazzina, Nicoletta; Doglioni, Nicoletta; Ferrarese, Paola; Marzari, Francesco; Zanardo, Vincenzo

    2005-06-01

    We compared the effectiveness of a new continuous positive airway pressure (CPAP) device (neonatal helmet CPAP) with a conventional nasal CPAP system in preterm neonates needing continuous distending pressure. Randomized, physiological, cross-over study in a tertiary referral, neonatal intensive care unit in a university teaching hospital. Twenty very low birth weight infants with a postnatal age greater than 24 h who were receiving nasal CPAP for apnea and/or mild respiratory distress were enrolled. CPAP delivered by neonatal helmet CPAP and nasal CPAP in random order for two subsequent 90-min periods. Were continuously measured the Neonatal Infant Pain Scale (NIPS) score, oxygen requirements, respiratory rate, heart rate, oxygen saturation, transcutaneous PO(2) (tcPO(2)) and PCO(2) (tcPCO(2)), blood pressure, and desaturations. NIPS scores were significantly lower when the infants were on the neonatal helmet CPAP than when they were on nasal CPAP (0.26+/-0.07 vs. 0.63+/-0.12). The other studied parameters did not differ between the two CPAP modes. The number of desaturations was reduced during the neonatal helmet CPAP treatment (18 vs. 32), although this difference was not significant. In this short-term physiological study the neonatal helmet CPAP appears to be as good as the golden standard for managing preterm infants needing continuous distending pressure, with enhanced tolerability. Further evaluation in a randomized clinical trial is needed to confirm these findings.

  12. Sleep apnea is associated with bronchial inflammation and continuous positive airway pressure-induced airway hyperresponsiveness.

    Science.gov (United States)

    Devouassoux, Gilles; Lévy, Patrick; Rossini, Eliane; Pin, Isabelle; Fior-Gozlan, Michèle; Henry, Mireille; Seigneurin, Daniel; Pépin, Jean-Louis

    2007-03-01

    Obstructive sleep apnea syndrome (OSA) is associated with systemic and upper airway inflammation. Pharyngeal inflammation has a potential role in upper airway collapse, whereas systemic inflammation relates to cardiovascular morbidity. However, the presence of an inflammatory involvement of lower airway has been poorly investigated. The aim of the study was to demonstrate an inflammatory process at the bronchial level in patients with OSA and to analyze effects of continuous positive airway pressure (CPAP) application and humidification on bronchial mucosa. The study was conducted by using sequential induced sputum for cell analysis and IL-8 production, nitric oxide exhalation measurement, and methacholine challenge before and after CPAP. Bronchial neutrophilia and a high IL-8 concentration were observed in untreated OSA compared with controls (75% +/- 20% vs 43% +/- 12%, P Obstructive sleep apnea syndrome is associated with bronchial inflammation. Our data demonstrate CPAP effect on the development of AHR, possibly facilitated by the pre-existing inflammation. Both issues should be evaluated during long-term CPAP use. Results showing a spontaneous bronchial inflammation in OSA and the development of a CPAP-related AHR require a long-term follow-up to evaluate consequences on chronic bronchial obstruction.

  13. Continuous positive airway pressure for the treatment of obstructive sleep apnea.

    Science.gov (United States)

    Nurwidya, Fariz; Susanto, Agus Dwi; Juzar, Dafsah A; Kobayashi, Isao; Yunus, Faisal

    2016-01-01

    Obstructive sleep apnea (OSA) is a recurrent episode of partial or complete upper airway obstruction during sleep despite ongoing respiratory efforts and is implicated as the risk factor of cardiovascular disease. The OSA syndrome is typified by recurring partial or total occlusion of the pharynx, sleep fragmentation, episodes of gasping, and, eventually, daytime sleepiness. If it is left untreated, OSA syndrome can cause hypertension, coronary artery disease congestive heart disease, insulin resistance and death. In this review, we describe the pathogenesis and diagnosis of OSA. We also focused on the continuous positive airway pressure (CPAP) as the main therapy for OSA. CPAP has been shown to provide benefit for not only respiratory system, but also for cardiovascular system and metabolic system. Finally, we discussed briefly about the issue of adherence of using CPAP that could contribute to lower compliant in patient with OSA.

  14. Effect of Filters on the Noise Generated by Continuous Positive Airway Pressure Delivered via a Helmet

    Directory of Open Access Journals (Sweden)

    Ricardo Hernández-Molina

    2017-01-01

    Full Text Available Introduction: One of the problems that the delivery of continuous positive airway pressure (CPAP via a helmet poses is the generation of noise. The objective of our study was to assess the effect that the use of filter has on sound pressure levels generated by the delivery of positive airway pressure at different gas flow rates. Materials and Methods: Sound pressure levels generated by neonatal helmet CPAP delivery were measured at different gas flows (20, 30, and 40 l/min with and without a breathing filter. Noise intensity was measured by installing microphones in the inner ear of dummy heads wearing helmets. Results: The sound pressure level increased by 38% at a gas flow of 40 l/min, as compared to a gas flow of 20 l/min {74 dBA [interquartile range (IQR 2,2] vs 52 dBA (IQR 5,9, respectively}. Using the breathing filter as a diffuser has a variety of effects on sound pressure levels according to the gas flow rate. Conclusion: The intensity of the noise generated by helmet delivery of positive airway pressure depends on the type of helmet used, gas flow, and use or not of a diffuser filter. Breathing filters with gas flows over 30 l/min might not be recommended since they would not attenuate but will rather amplify sound pressure.

  15. Simulated driving in obstructive sleep apnoea-hypopnoea : effects of oral appliances and continuous positive airway pressure

    NARCIS (Netherlands)

    Hoekema, Aarnoud; Stegenga, Boudewijn; Bakker, Marije; Brouwer, Wiebo H.; de Bont, Lambert G. M.; Wijkstra, Peter J.; van der Hoeven, Johannes H.

    Impaired simulated driving performance has been demonstrated in obstructive sleep apnoea-hypopnoea syndrome (OSAHS) patients. Although continuous positive airway pressure (CPAP) generally improves simulated driving performance, the effects of oral-appliance (OA) therapy are unknown. The aims of this

  16. Increased airway reactivity in a neonatal mouse model of Continuous Positive Airway Pressure (CPAP)

    Science.gov (United States)

    Mayer, Catherine A.; Martin, Richard J.; MacFarlane, Peter M.

    2015-01-01

    Background Continuous positive airway pressure (CPAP) is a primary form of respiratory support used in the intensive care of preterm infants, but its long-term effects on airway (AW) function are unknown. Methods We developed a neonatal mouse model of CPAP treatment to determine whether it modifies later AW reactivity. Un-anesthetized spontaneously breathing mice were fitted with a mask to deliver CPAP (6cmH2O, 3hrs/day) for 7 consecutive days starting at postnatal day 1. Airway reactivity to methacholine was assessed using the in vitro living lung slice preparation. Results One week of CPAP increased AW responsiveness to methacholine in male, but not female mice, compared to untreated control animals. The AW hyper-reactivity of male mice persisted for 2 weeks (at P21) after CPAP treatment ended. 4 days of CPAP, however, did not significantly increase AW reactivity. Females also exhibited AW hyper-reactivity at P21, suggesting a delayed response to early (7 days) CPAP treatment. The effects of 7 days of CPAP on hyper-reactivity to methacholine were unique to smaller AWs whereas larger ones were relatively unaffected. Conclusion These data may be important to our understanding of the potential long-term consequences of neonatal CPAP therapy used in the intensive care of preterm infants. PMID:25950451

  17. Nasal continuous positive airways pressure immediately after extubation for preventing morbidity in preterm infants.

    Science.gov (United States)

    Davis, P G; Henderson-Smart, D J

    2003-01-01

    Preterm infants being extubated following a period of intermittent positive pressure ventilation via an endotracheal tube are at risk of developing respiratory failure as a result of apnea, respiratory acidosis and hypoxia. Nasal continuous positive airway pressure appears to stabilise the upper airway, improve lung function and reduce apnea and may therefore have a role in facilitating extubation in this population. In preterm infants having their endotracheal tube removed following a period of intermittent positive pressure ventilation (IPPV), does management with nasal continuous positive airways pressure (NCPAP) lead to an increased proportion remaining free of additional ventilatory support, compared to extubation directly to headbox oxygen? Searches were made of the Oxford Database of Perinatal Trials, MEDLINE up to November 2002, Cochrane Controlled Trials Register (The Cochrane Library, Issue 4, 2002), previous reviews including cross references, abstracts of conferences and symposia proceedings, expert informants and journal handsearching mainly in the English language. All trials utilising random or quasi-random patient allocation, in which NCPAP (delivered by any method) was compared with headbox oxygen for post-extubation care were included. Methodological quality was assessed independently by the two authors. Data were extracted independently by the two authors. Prespecified subgroup analysis to determine the impact of different levels of NCPAP, differences in duration of IPPV and use of aminophylline were also performed using the same package. Data were analysed using relative risk (RR), risk difference (RD) and number needed to treat (NNT). Nasal CPAP, when applied to preterm infants being extubated following IPPV, reduces the incidence of adverse clinical events (apnea, respiratory acidosis and increased oxygen requirements) indicating the need for additional ventilatory support [RR 0.62 (0.49, 0.77), RD -0.17 (-0.24,-0.10), NNT 6 (4,10)]. nasal

  18. Bilateral parotitis in a patient under continuous positive airway pressure treatment.

    Science.gov (United States)

    Abdullayev, Ruslan; Saral, Filiz Cosku; Kucukebe, Omer Burak; Sayiner, Hakan Sezgin; Bayraktar, Cem; Akgun, Sadik

    Many conditions such as bacterial and viral infectious diseases, mechanical obstruction due to air and calculi and drugs can cause parotitis. We present a case of unusual bilateral parotitis in a patient under non-invasive continuous positive airway pressure (CPAP) therapy for chronic obstructive pulmonary disease exacerbation in intensive care unit. A 36-year-old patient was admitted to intensive care unit with the diagnosis of chronic obstructive pulmonary disease exacerbation. Antibiotherapy, bronchodilator therapy and non-invasive positive pressure ventilation were applied as treatment regimen. Painless swellings developed on the 3rd day of admission on the right and a day after this on the left parotid glands. Amylase levels were increased and ultrasonographic evaluation revealed bilateral parotitis. No intervention was made and the therapy was continued. The patient was discharged on the 6th day with clinical improvement and regression of parotid swellings without any complications. Parotitis may have occurred after retrograde air flow in the Stensen duct during CPAP application. After the exclusion of possible viral and bacteriological etiologies and possible drug reactions we can focus on this diagnosis. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  19. Understanding the use of continuous oscillating positive airway pressure (bubble CPAP) to treat neonatal respiratory disease: an engineering approach.

    Science.gov (United States)

    Manilal-Reddy, P I; Al-Jumaily, A M

    2009-01-01

    A continuous oscillatory positive airway pressure with pressure oscillations incidental to the mean airway pressure (bubble CPAP) is defined as a modified form of traditional continuous positive airway pressure (CPAP) delivery where pressure oscillations in addition to CPAP are administered to neonates with lung diseases. The mechanical effect of the pressure oscillations on lung performance is investigated by formulating mathematical models of a typical bubble CPAP device and a simple representation of a neonatal respiratory system. Preliminary results of the respiratory system's mechanical response suggest that bubble CPAP may improve lung performance by minimizing the respiratory system impedance and that the resonant frequency of the respiratory system may be a controlling factor. Additional steps in terms of clinical trials and a more complex respiratory system model are required to gain a deeper insight into the mechanical receptiveness of the respiratory system to pressure oscillations. However, the current results are promising in that they offer a deeper insight into the trends of variations that can be expected in future extended models as well as the model philosophies that need to be adopted to produce results that are compatible with experimental verification.

  20. Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea.

    Science.gov (United States)

    Rudkowski, J C; Verschelden, P; Kimoff, R J

    2001-09-01

    The aim of this study was to evaluate manual nasal continuous positive airway pressure (nCPAP) titration during daytime polysomnography compared with conventional overnight titration for patients with severe obstructive sleep apnoea. Thirty-two patients who underwent daytime titration were retrospectively matched (for age, sex, body mass index and apnoea/hypopnoea index (AHI)) to a group titrated overnight during the same period. Successful titration was defined as the identification of the nCPAP level (effective nCPAP (Peff)) required to eliminate respiratory events during all sleep stages. After 3 months of therapy on nCPAP at Peff, nCPAP utilization history was obtained and a group of patients underwent a repeat polysomnogram (PSG) and completed a follow-up Epworth Sleepiness Scale (ESS) score. Initial titration was successful in 91% of daytime patients and 91% of overnight patients. The success of daytime titration was not related to diagnostic AHI or ESS score. Subjective nCPAP utilization was statistically similar in both groups. On the follow-up PSG, there were no significant differences between daytime (n=11) and overnight (n=11) patients in measures of sleep quality or respiratory disturbance. Both groups demonstrated similar and significant improvements in ESS score. These findings suggest that the effective nasal continuous positive airway pressure can be accurately established during daytime titration in a substantial proportion of severe, symptomatic obstructive sleep apnoea patients.

  1. Continuous positive airway pressure breathing increases cranial spread of sensory blockade after cervicothoracic epidural injection of lidocaine.

    NARCIS (Netherlands)

    Visser, W.A.; Eerd, M.J. van; Seventer, R. van; Gielen, M.J.M.; Giele, J.L.P.; Scheffer, G.J.

    2007-01-01

    BACKGROUND: Continuous positive airway pressure (CPAP) increases the caudad spread of sensory blockade after low-thoracic epidural injection of lidocaine. We hypothesized that CPAP would increase cephalad spread of blockade after cervicothoracic epidural injection. METHODS: Twenty patients with an

  2. The NOFLO trial: low-flow nasal prongs therapy in weaning nasal continuous positive airway pressure in preterm infants.

    LENUS (Irish Health Repository)

    O'Donnell, Sinéad M

    2013-07-01

    To determine if low-flow nasal prongs therapy with room air, compared with no treatment, facilitates weaning from nasal continuous positive airway pressure (NCPAP) in very low birth weight (VLBW, birth weight <1500 g) infants.

  3. Does personality play a role in continuous positive airway pressure compliance?

    Directory of Open Access Journals (Sweden)

    Emily L. Maschauer

    2017-03-01

    Continuous positive airway pressure (CPAP adherence is low among individuals with obstructive sleep apnoea. Type D personality and high scores on the depression and hypochondriasis scales on the Minnesota Multiphasic Personality Inventory (MMPI have been identified as factors contributing to non-compliance with CPAP. Further research into personality type may assist in understanding why some people adhere to CPAP, while others fail. Obstructive sleep apnoea (OSA is a condition characterised by repetitive, intermittent partial or complete collapse/obstruction of the upper airway during sleep. Continuous positive airway pressure (CPAP is highly efficacious in treating OSA but its effectiveness is limited due to suboptimal acceptance and adherence rates, with as many as 50% of OSA patients discontinuing CPAP treatment within the first year. Until recently, research has focused on examining mechanistic and demographic factors that could explain nonadherence (e.g. age, sex, race and education level with limited applicability in a prospective or clinical manner. More recent research has focused on personality factors or types of patients with OSA who comply and do not comply with CPAP adherence in an attempt to enhance the accuracy of predicting treatment compliance. Type D personality has been found to be prevalent in one third of patients with OSA. The presence of Type D personality increases noncompliance and poor treatment outcomes due to negative affectivity, social inhibition, unhealthy lifestyle, and a reluctance to consult and/or follow medical advice. Conversely, individuals who are more likely to adhere to CPAP treatment tend to have a high internal locus of control and high self-efficacy, self-refer for treatment, and have active coping skills. By assessing personality and coping skills, the clinician may gain insight into the likelihood of a patient’s adherence to treatment. If the patient displays potential risk factors for CPAP noncompliance, the

  4. Noninvasive Positive Pressure Ventilation or Conventional Mechanical Ventilation for Neonatal Continuous Positive Airway Pressure Failure

    Directory of Open Access Journals (Sweden)

    Zohreh Badiee

    2014-01-01

    Full Text Available Background: The aim of this study was to assess the success rate of nasal intermittent positive pressure ventilation (NIPPV for treatment of continuous positive airway pressure (CPAP failure and prevention of conventional ventilation (CV in preterm neonates. Methods: Since November 2012 to April 2013, a total number of 55 consecutive newborns with gestational ages of 26-35 weeks who had CPAP failure were randomly assigned to one of the two groups. The NIPPV group received NIPPV with the initial peak inspiratory pressure (PIP of 16-20 cmH 2 O and frequency of 40-60 breaths/min. The CV group received PIP of 12-20 cmH 2 O and frequency of 40-60 breaths/min. Results: About 74% of newborns who received NIPPV for management of CPAP failure responded to NIPPV and did not need intubation and mechanical ventilation. Newborns with lower postnatal age at entry to the study and lower 5 min Apgar score more likely had NIPPV failure. In addition, treatment failure was higher in newborns who needed more frequent doses of surfactant. Duration of oxygen therapy was 9.28 days in CV group and 7.77 days in NIPPV group (P = 0.050. Length of hospital stay in CV group and NIPPV groups were 48.7 and 41.7 days, respectively (P = 0.097. Conclusions: NIPPV could decrease the need for intubation and mechanical ventilation in preterm infants with CPAP failure.

  5. Continuous Positive Airway Pressure Prevents Hypoxia in Dental Patient with Obstructive Sleep Apnea Syndrome under Intravenous Sedation.

    Science.gov (United States)

    Kasatkin, Anton A; Reshetnikov, Aleksei P; Urakov, Aleksandr L; Baimurzin, Dmitrii Y

    2017-01-01

    Use of sedation in patients with obstructive sleep apnea (OSA) in dentistry is limited. Hypoxia may develop during medication sleep in dental patients with OSA because of repetitive partial or complete obstruction of the upper airway. In this regard, anesthesiologists prefer not to give any sedative to surgical patients with OSA or support the use of general anesthesia due to good airway control. We report a case where we could successfully sedate a dental patient with OSA using intraoperative continuous positive airway pressure (CPAP) without hypoxia. Use of sedation and intraoperative CPAP in patients with OSA may be considered only if the effectiveness at home CPAP therapy is proven.

  6. Predicting uptake of continuous positive airway pressure (CPAP) therapy in obstructive sleep apnoea (OSA)

    DEFF Research Database (Denmark)

    Skinner, Timothy; McNeil, Lindsay; Olaithe, Michelle

    2013-01-01

    diagnosed with OSA. Epworth sleepiness scale (ESS), Fatigue Severity Scale, Depression Anxiety Stress Scale and Illness Perception Questionnaire-Revised (IPQ-R) were administered at time of sleep study. These, patient demographics and sleep study variables were used to determine factors predicting patient......Purpose: Obstructive sleep apnoea (OSA) is a common disorder, for which continuous positive airway pressure (CPAP) therapy is a standard treatment. Despite its well-established efficacy, many patients choose not to initiate CPAP treatment. The present study investigated the degree to which...

  7. Continuous positive airway pressure treatment increases bronchial reactivity in obstructive sleep apnea patients.

    Science.gov (United States)

    Korczynski, Piotr; Gorska, Katarzyna; Przybylowski, Tadeusz; Bielicki, Piotr; Zielinski, Jan; Chazan, Ryszarda

    2009-01-01

    The effects of continuous positive airway pressure (CPAP) treatment on the function of the lower airways are poorly understood. One of the methods used to determine the influence of positive pressure breathing on lower airways is the bronchial hyperreactivity test. Some authors report that CPAP increases bronchial hyperreactivity, while others report decreases. To assess the influence of CPAP treatment on bronchial reactivity and the effects of bronchial hyperreactivity on compliance to CPAP treatment. The study group consisted of 101 obstructive sleep apnea syndrome patients (88 men and 13 women) with a mean age of 51 ± 11 years, mean apnea-hypopnea index of 53 ± 20 and mean body mass index of 32.6 ± 5.4. Patients were randomly assigned to a treatment group that received 3 weeks of CPAP therapy (group 1) or to a nontreatment control group (group 2). Pulmonary function tests and the methacholine bronchial provocation test were performed at baseline and 3 weeks later. There were no statistically significant differences between treated and control groups in anthropometry and polysomnography variables. At baseline, bronchial hyperreactivity was found in 6 patients from group 1 and 5 patients from group 2. A significant increase in bronchial reactivity was observed after CPAP treatment. Log PC20M decreased from 1.38 ± 0.30 at baseline to 1.26 ± 0.50 (p bronchial hyperreactivity during CPAP treatment were characterized by significantly lower FEV1, FVC and MEF50 values. CPAP produces statistically significant bronchial hyperreactivity. However, there were no clinical symptoms and it is not necessary to withdraw previous therapies. Copyright © 2009 S. Karger AG, Basel.

  8. Treatment of presumed acute cardiogenic pulmonary oedema in an ambulance system by nurses using Boussignac continuous positive airway pressure

    NARCIS (Netherlands)

    Dieperink, Willem; Weelink, E. E. M.; van der Horst, I. C. C.; de Vos, R.; Jaarsma, T.; Aarts, L. P. H. J.; Zijlstra, F.; Nijsten, M. W. N.

    Background: Early initiation of continuous positive airway pressure (CPAP) applied by face mask benefits patients with acute cardiogenic pulmonary oedema (ACPE). The simple disposable Boussignac CPAP (BCPAP) has been used in ambulances by physicians. In the Netherlands, ambulances are manned by

  9. Randomised trial of elective continuous positive airway pressure (CPAP) compared with rescue CPAP after extubation

    OpenAIRE

    Robertson, N; Hamilton, P

    1998-01-01

    AIM—To determine if a weaning regimen on flow driver continuous positive airway pressure (CPAP) would decrease the number of ventilator days but increase the number of CPAP days when compared with a rescue regimen.
METHODS—Fifty eight babies of 24-32 weeks gestation with respiratory distress syndrome (RDS) were studied prospectively. After extubation they were randomly allocated to receive CPAP for 72 hours (n=29) according to a weaning regimen, or were placed in headbox ...

  10. Evaluation of a continuous-positive pressure generating system

    Directory of Open Access Journals (Sweden)

    Herrera N

    2016-03-01

    Full Text Available Nestor Herrera,1,2 Roberto Regnícoli,1,2 Mariel Murad1,2 1Neonatology Unit, Italian Hospital Garibaldi, Rosario, Argentina; 2Experimental Medicine and Surgery Unit, Italian University Institute of Rosario, Argentina Abstract: The use of systems that apply continuous-positive airway pressure by means of noninvasive methods is widespread in the neonatal care practice and has been associated with a decrease in the use of invasive mechanical ventilation, less administration of exogenous surfactant, and bronchopulmonary dysplasia. Few experimental studies on the functioning of the neonatology systems that generate continuous-positive airway pressure have been reported. A flow resistor system associated with an underwater seal resistor in a lung test model was described, and it was compared with an underwater seal threshold resistor system. Important differences in the pressures generated in the different systems studied were verified. The generation of pressure was associated with the immersion depth and the diameter of the bubble tubing. The flow resistor associated with an underwater seal, with small bubble tubing, showed no important differences in the evaluated pressures, exerting a stabilizing effect on the generated pressures. The importance of measuring the pressure generated by the different systems studied was verified, due to the differences between the working pressures set and the pressures measured. Keywords: continuous-positive pressure, flow and threshold resistor, BCPAP

  11. Oral continuous positive airway pressure (CPAP) following nasal injury in a preterm infant.

    Science.gov (United States)

    Carlisle, H R; Kamlin, C O F; Owen, L S; Davis, P G; Morley, C J

    2010-03-01

    Non-invasive respiratory support is increasingly popular but is associated with complications including nasal trauma. The present report describes a novel method of oral continuous positive airway pressure (CPAP) delivery in an extremely premature infant with severe nasal septum erosion. The distal end of a cut down endotracheal tube was passed through a small hole made in the teat of a dummy (infant pacifier) and sutured in place. The dummy was secured in the infant's mouth and CPAP was delivered to the pharynx. The device was well tolerated and the infant was successfully managed using this technique for 48 days, avoiding endotracheal intubation and ventilation.

  12. A Randomized Trial of Low-Flow Oxygen versus Nasal Continuous Positive Airway Pressure in Preterm Infants

    DEFF Research Database (Denmark)

    Heiring, Christian; Steensberg, Jesper; Bjerager, Mia

    2015-01-01

    BACKGROUND: Nasal continuous positive airway pressure (nCPAP) stabilizes the residual volume and may decrease the risk of 'atelectotrauma', potentially promoting lung development in neonates. OBJECTIVES: To assess whether replacing nCPAP by low-flow O2 by nasal cannula affects lung function...... the a/A pO2 ratio or weight gain negatively. Thus, prolonged nCPAP seems not to have a positive effect on lung function at 28 days of life and replacement by low-flow O2 could reduce the cost of equipment and increase the ease of nursing....

  13. Sibutramine versus continuous positive airway pressure in obese obstructive sleep apnoea patients.

    Science.gov (United States)

    Ferland, A; Poirier, P; Sériès, F

    2009-09-01

    The aim of the present study was to compare the efficacy of 1 yr of sibutramine-induced weight loss versus continuous positive airway pressure (CPAP) treatment on sleep-disordered breathing, cardiac autonomic function and systemic blood pressure in obese patients with obstructive sleep apnoea. Subjects with a body mass index of > or =30 kg.m(-2) without previous treatment for obstructive sleep apnoea underwent either sibutramine (n = 22) or CPAP (n = 18) treatment for 1 yr. Sibutramine induced a 5.4+/-1.4 kg decrease in body weight compared to the CPAP group, in which no changes in anthropometric variables were observed. The CPAP treatment improved all sleep and respiratory variables, whereas sibutramine-induced weight loss improved only nocturnal arterial oxygen saturation profile. Only CPAP treatment improved night-time systolic and diastolic blood pressure and 24-h and daytime ambulatory diastolic blood pressure. Sibutramine-induced weight loss had no impact on indices of heart rate variability, whereas CPAP treatment increased daytime time domain indices. CPAP treatment for 1 yr had beneficial impacts on nocturnal breathing disturbances, and improved nocturnal oxygenation, night-time systolic and diastolic blood pressure, and daytime cardiac parasympathetic modulation. Sibutramine did not improve sleep-disordered breathing, systemic blood pressure or heart rate variability. There were no adverse effects, such as increment in blood pressure or arrhythmias, associated with this treatment regimen.

  14. All-cause mortality from obstructive sleep apnea in male and female patients with and without continuous positive airway pressure treatment

    DEFF Research Database (Denmark)

    Jennum, Poul; Tønnesen, Philip; Ibsen, Rikke

    2015-01-01

    BACKGROUND: More information is needed about the effect on mortality of continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea (OSA), especially in women. METHODS: We employed a historical cohort study design, using data from 25,389 patients with a diagnosis of OSA...

  15. The effect of obstructive sleep apnea and treatment with continuous positive airway pressure on stroke rehabilitation: rationale, design and methods of the TOROS study

    NARCIS (Netherlands)

    Aaronson, Justine A.; van Bennekom, Coen A. M.; Hofman, Winni F.; van Bezeij, Tijs; van den Aardweg, Joost G.; Groet, Erny; Kylstra, Wytske A.; Schmand, Ben A.

    2014-01-01

    Obstructive sleep apnea is a common sleep disorder in stroke patients. Obstructive sleep apnea is associated with stroke severity and poor functional outcome. Continuous positive airway pressure seems to improve functional recovery in stroke rehabilitation. To date, the effect of continuous positive

  16. Bilateral diaphragmatic paralysis after cardiac surgery: ventilatory assistance by nasal mask continuous positive airway pressure.

    Science.gov (United States)

    Hoch, B; Zschocke, A; Barth, H; Leonhardt, A

    2001-01-01

    The case of an 8-month-old boy with bilateral diaphragmatic paralysis after surgical reoperation for congenital heart disease is presented. In order to avoid repeated intubation and long-term mechanical ventilation or tracheotomy, we used nasal mask continuous positive airway pressure (CPAP) as an alternative method for assisted ventilation. Within 24 hours the boy accepted the nasal mask and symptoms such as dyspnea and sweating disappeared. Respiratory movements became regular and oxygen saturation increased. Nasal mask CPAP may serve as an alternative treatment of bilateral diaphragmatic paralysis in infants, thereby avoiding tracheotomy or long-term mechanical ventilation.

  17. Choosing an Oronasal Mask to Deliver Continuous Positive Airway Pressure May Cause More Upper Airway Obstruction or Lead to Higher Continuous Positive Airway Pressure Requirements than a Nasal Mask in Some Patients: A Case Series.

    Science.gov (United States)

    Ng, Justin R; Aiyappan, Vinod; Mercer, Jeremy; Catcheside, Peter G; Chai-Coetzer, Ching Li; McEvoy, R Doug; Antic, Nick

    2016-09-15

    The choice of mask interface used with continuous positive airway pressure (CPAP) therapy can affect the control of upper airway obstruction (UAO) in obstructive sleep apnea (OSA). We describe a case series of four patients with paradoxical worsening of UAO with an oronasal mask and the effect of changing to a nasal mask. We retrospectively reviewed the case histories of 4 patients and recorded patient demographics, in-laboratory and ambulatory CPAP titration data, CPAP therapy data, type of mask interface used and potential confounding factors. The 4 cases (mean ± SD: age = 59 ± 16 y; BMI = 30.5 ± 4.5 kg/m(2)) had a high residual apnoea-hypopnea index (AHI) (43 ± 14.2 events/h) and high CPAP pressure requirements (14.9 ± 6.6 cmH2O) with an oronasal mask. Changing to a nasal mask allowed adequate control of UAO with a significant reduction in the average residual AHI (3.1 ± 1.5 events/h). In two of the four cases, it was demonstrated that control of UAO was obtained at a much lower CPAP pressure compared to the oronasal mask (Case one = 17.5 cmH2O vs 12cmH2O; Case two = 17.9 cmH2O vs 7.8 cmH2O). Other potential confounding factors were unchanged. There are various physiological observations that may explain these findings but it is uncertain which individuals are susceptible to these mechanisms. If patients have OSA incompletely controlled by CPAP with evidence of residual UAO and/or are requiring surprisingly high CPAP pressure to control OSA with an oronasal mask, the choice of mask should be reviewed and consideration be given to a trial of a nasal mask. A commentary on this article appears in this issue on page 1209. © 2016 American Academy of Sleep Medicine.

  18. Effects of Continuous Positive Airway Pressure on Cognitive and Functional Outcome of Stroke Patients with Obstructive Sleep Apnea : A Randomized Controlled Trial

    NARCIS (Netherlands)

    Aaronson, J.A.; Hofman, W.F.; van Bennekom, C.A.M.; van Bezeij, T.; van den Aardweg, J.G.; Groet, E.; Kylstra, W.A.; Schmand, B.

    2016-01-01

    STUDY OBJECTIVES: Obstructive sleep apnea (OSA) in stroke patients is associated with worse functional and cognitive status during inpatient rehabilitation. We hypothesized that a four-week period of continuous positive airway pressure (CPAP) treatment would improve cognitive and functional

  19. [Comparison of different continuous positive airway pressure titration methods for obstructive sleep apnea hypopnea syndrome].

    Science.gov (United States)

    Li, Jingjing; Ye, Jingying; Zhang, Peng; Kang, Dan; Cao, Xin; Zhang, Yuhuan; Ding, Xiu; Zheng, Li; Li, Hongguang; Bian, Qiuli

    2014-10-01

    To explore whether there were differences between the results of automatic titration and the results of manual titration for positive airway pressure treatment in patients with obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors, the results might provide a theoretical basis for the rational use of two pressure titration methods. Sixty one patients with OSAHS were included in this study. All patients underwent a manual titration and an automatic titration within one week. The clinical informations, polysomnography data, and the results of both two titration of all patients were obtained for analysis. The overall apnea/hypopnea index was (63.1 ± 17.7)/h, with a range of 14.9/h to 110.4/h. The treatment pressure of manual titration was (8.4 ± 2.1) cmH(2)O, which was significantly lower than the treatment pressure of automatic titration, (11.5 ± 2.7) cmH(2)O (t = -9.797, P titration and manual titration), it was found that the pressure of automatic titration was significantly higher in patients with a ΔP > 3 cmH(2)O than in patients with a ΔP ≤ 3 cmH(2)O, which was (13.3 ± 2.3) cmH(2)O vs (10.0 ± 2.0) cmH(2)O (t = -6.159, P titration between these two groups, which was (8.6 ± 2.4) cmH(2)O vs (8.3 ± 2.0)cmH(2)O (P > 0.05). There was no significant difference in age, body mass index, neck circumference, abdomen circumference, apnea hypopnea index, and arterial oxygen saturation between these two groups. The treatment pressure of automatic titration is usually higher than that of manual titration. For patients with a high treatment pressure which is derived from automatic titration, a suggestion about manual titration could be given to decrease the potential treatment pressure of continuous positive airway pressure, which may be helpful in improving the comfortableness and the compliance of this treatment.

  20. Effects of continuous positive airway pressure on neurocognitive function in obstructive sleep apnea patients: The Apnea Positive Pressure Long-term Efficacy Study (APPLES).

    Science.gov (United States)

    Kushida, Clete A; Nichols, Deborah A; Holmes, Tyson H; Quan, Stuart F; Walsh, James K; Gottlieb, Daniel J; Simon, Richard D; Guilleminault, Christian; White, David P; Goodwin, James L; Schweitzer, Paula K; Leary, Eileen B; Hyde, Pamela R; Hirshkowitz, Max; Green, Sylvan; McEvoy, Linda K; Chan, Cynthia; Gevins, Alan; Kay, Gary G; Bloch, Daniel A; Crabtree, Tami; Dement, William C

    2012-12-01

    To determine the neurocognitive effects of continuous positive airway pressure (CPAP) therapy on patients with obstructive sleep apnea (OSA). The Apnea Positive Pressure Long-term Efficacy Study (APPLES) was a 6-month, randomized, double-blind, 2-arm, sham-controlled, multicenter trial conducted at 5 U.S. university, hospital, or private practices. Of 1,516 participants enrolled, 1,105 were randomized, and 1,098 participants diagnosed with OSA contributed to the analysis of the primary outcome measures. Active or sham CPAP MEASUREMENTS: THREE NEUROCOGNITIVE VARIABLES, EACH REPRESENTING A NEUROCOGNITIVE DOMAIN: Pathfinder Number Test-Total Time (attention and psychomotor function [A/P]), Buschke Selective Reminding Test-Sum Recall (learning and memory [L/M]), and Sustained Working Memory Test-Overall Mid-Day Score (executive and frontal-lobe function [E/F]) The primary neurocognitive analyses showed a difference between groups for only the E/F variable at the 2 month CPAP visit, but no difference at the 6 month CPAP visit or for the A/P or L/M variables at either the 2 or 6 month visits. When stratified by measures of OSA severity (AHI or oxygen saturation parameters), the primary E/F variable and one secondary E/F neurocognitive variable revealed transient differences between study arms for those with the most severe OSA. Participants in the active CPAP group had a significantly greater ability to remain awake whether measured subjectively by the Epworth Sleepiness Scale or objectively by the maintenance of wakefulness test. CPAP treatment improved both subjectively and objectively measured sleepiness, especially in individuals with severe OSA (AHI > 30). CPAP use resulted in mild, transient improvement in the most sensitive measures of executive and frontal-lobe function for those with severe disease, which suggests the existence of a complex OSA-neurocognitive relationship. Registered at clinicaltrials.gov. Identifier: NCT00051363. Kushida CA; Nichols DA; Holmes

  1. Oral appliance therapy versus nasal continuous positive airway pressure in obstructive sleep apnea: a randomized, placebo-controlled trial on psychological distress

    NARCIS (Netherlands)

    Aarab, Ghizlane; Nikolopoulou, Maria; Ahlberg, Jari; Heymans, Martijn W.; Hamburger, Hans L.; de Lange, Jan; Lobbezoo, Frank

    2017-01-01

    The aim of this randomized placebo-controlled trail was to compare the effects of an objectively titrated mandibular advancement device (MAD) with those of nasal continuous positive airway pressure (nCPAP) and an intraoral placebo device on symptoms of psychological distress in OSA patients. In a

  2. Effects of Continuous Positive Airway Pressure on Cognitive and Functional Outcome of Stroke Patients with Obstructive Sleep Apnea: A Randomized Controlled Trial

    NARCIS (Netherlands)

    Aaronson, Justine A.; Hofman, Winni F.; van Bennekom, Coen A. M.; van Bezeij, Tijs; van den Aardweg, Joost G.; Groet, Erny; Kylstra, Wytske A.; Schmand, Ben

    2016-01-01

    Obstructive sleep apnea (OSA) in stroke patients is associated with worse functional and cognitive status during inpatient rehabilitation. We hypothesized that a four-week period of continuous positive airway pressure (CPAP) treatment would improve cognitive and functional outcomes. We performed a

  3. EXTUBATE: A randomised controlled trial of nasal biphasic positive airway pressure vs. nasal continuous positive airway pressure following extubation in infants less than 30 weeks' gestation: study protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Victor Suresh

    2011-12-01

    Full Text Available Abstract Background Respiratory distress syndrome remains a significant problem among premature infants. Mechanical ventilation through an endotracheal tube remains the mainstay of respiratory support but may be associated with lung injury and the development of chronic lung disease of prematurity. Efforts are needed to reduce the duration of mechanical ventilation in favour of less invasive forms of respiratory support and to improve rates of successful extubation. Non-invasive respiratory support has been demonstrated to be less injurious to the premature lung. Standard practice is to use nasal continuous positive airway pressure (n-CPAP following extubation to support the baby's breathing. Many clinicians also use nasal biphasic positive airway pressure (n-BiPAP in efforts to improve rates of successful extubation. However, there is currently no evidence that this confers any advantage over conventional nasal continuous positive airway pressure. Methods We propose an unblinded multi-centre randomised trial comparing n-CPAP with n-BiPAP in babies born before 30 weeks' gestation and less than two weeks old. Babies with congenital abnormalities and severe intra-ventricular haemorrhage will be excluded. 540 babies admitted to neonatal centres in England will be randomised at the time of first extubation attempt. The primary aim of this study is to compare the rate of extubation failure within 48 hours following the first attempt at extubation. The secondary aims are to compare the effect of n-BiPAP and n-CPAP on the following outcomes: 1. Maintenance of successful extubation for 7 days post extubation 2. Oxygen requirement at 28 days of age and at 36 weeks' corrected gestational age 3. Total days on ventilator, n-CPAP/n-BiPAP 4. Number of ventilator days following first extubation attempt 5. pH and partial pressure of carbon dioxide in the first post extubation blood gas 6. Duration of hospital stay 7. Rate of abdominal distension requiring

  4. The Role of Continuous Positive Airway Pressure Therapy in the Management of Respiratory Distress in Extremely Premature Infants

    OpenAIRE

    Sekar, Kris

    2006-01-01

    The use of mechanical ventilation for the treatment of respiratory distress syndrome (RDS) in low birth weight infants may cause barotrauma, volutrauma, and chronic lung disease. Different continuous positive airway pressure (CPAP) delivery systems exist, each with its own practical and clinical advantages and disadvantages. CPAP can be used as either a primary or an adjunctive respiratory support for RDS. Research demonstrates that CPAP decreases the incidence of respiratory failure after ex...

  5. Home continuous positive airway pressure for cardiopulmonary indications in infants and children.

    Science.gov (United States)

    Al-Iede, Montaha; Kumaran, Radhagini; Waters, Karen

    2018-04-30

    A number of reports exist regarding the use of continuous positive airway pressure (CPAP) to manage obstructive sleep apnoea (OSA) in children, which we term 'conventional CPAP'. In contrast, there are few reports of home CPAP use for other indications, which we have grouped under the term 'cardiopulmonary'. The aims of this study were to (1) document cardiopulmonary indications for CPAP use in a cohort of infants and children, and (2) evaluate its effectiveness in this group. Hospital records were reviewed for 645 patients who were commenced on long-term CPAP over a 10-year period at a single-tertiary hospital (Children's Hospital at Westmead). This study evaluated the group where the primary indication for CPAP was not OSA ('cardiopulmonary CPAP'). Data evaluated included: demographics, diagnoses, indications for CPAP, hours of use (compliance) and sleep study results at baseline and on CPAP. Of 645 children, 148 (23%) used home CPAP for cardiopulmonary indications; and 130 (87.8%) of these were included. For this group, mean age at CPAP initiation was 18.6 ± 33.6 months (range one week to 16.8 years). Cardiopulmonary indications for CPAP use included: primary airway diseases 65 (50%), chronic lung diseases 33 (25.4%), congenital heart disease (CHD) 20 (15.4%), and both CHD and airway malacia 12 (9.2%). All sleep study variables improved on CPAP relative to the diagnostic sleep study (p 4 h/night). Interstitial lung diseases and other cardiorespiratory disorders, often of congenital origin, can be effectively treated with home CPAP whether they are associated with OSA or not. Sleep studies demonstrated improved gas exchange, sleep and reduced work of breathing with CPAP use. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Sexual function and obstructive sleep apnea-hypopnea : A randomized clinical trial evaluating the effects of oral-appliance and continuous positive airway pressure therapy

    NARCIS (Netherlands)

    Hoekema, Aarnoud; Stel, Anna-Lucia; Stegenga, Boudewijn; van der Hoeven, Johannes H.; Wijkstra, Peter J.; van Driel, Mels F.; de Bont, Lambert G. M.

    Introduction. The obstructive sleep apnea-hypopnea syndrome (OSAHS) is associated with sexual dysfunction. Although successful treatment with continuous positive airway pressure (CPAP) has been demonstrated to improve sexual function, the effects of oral-appliance therapy are unknown. Aim. The aims

  7. Comparison of manual versus automatic continuous positive airway pressure titration and the development of a predictive equation for therapeutic continuous positive airway pressure in Chinese patients with obstructive sleep apnoea.

    Science.gov (United States)

    Luo, Jiaying; Xiao, Sichang; Qiu, Zhihui; Song, Ning; Luo, Yuanming

    2013-04-01

    Whether the therapeutic nasal continuous positive airway pressure (CPAP) derived from manual titration is the same as derived from automatic titration is controversial. The purpose of this study was to compare the therapeutic pressure derived from manual titration with automatic titration. Fifty-one patients with obstructive sleep apnoea (OSA) (mean apnoea/hypopnoea index (AHI) = 50.6 ± 18.6 events/h) who were newly diagnosed after an overnight full polysomnography and who were willing to accept CPAP as a long-term treatment were recruited for the study. Manual titration during full polysomnography monitoring and unattended automatic titration with an automatic CPAP device (REMstar Auto) were performed. A separate cohort study of one hundred patients with OSA (AHI = 54.3 ± 18.9 events/h) was also performed by observing the efficacy of CPAP derived from manual titration. The treatment pressure derived from automatic titration (9.8 ± 2.2 cmH(2)O) was significantly higher than that derived from manual titration (7.3 ± 1.5 cmH(2)O; P titration (54.3 ± 18.9 events/h before treatment and 3.3 ± 1.7 events/h after treatment; P titration pressure derived from REMstar Auto is usually higher than the pressure derived from manual titration. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  8. Nasal continuous positive airway pressure treatment: current realities and future.

    Science.gov (United States)

    Berthon-Jones, M; Lawrence, S; Sullivan, C E; Grunstein, R

    1996-11-01

    Nasal continuous positive airway pressure (CPAP) is a highly effective treatment for obstructive sleep apnea syndrome. The apnea/hypopnea index (AHI) is reduced 10-fold, but the patient dropout rate is up to 30%, and usage is typically 20/hour were recruited, with written informed consent. Subjects slept for a diagnostic night, followed by a treatment night, in the laboratory, using the AutoSet system with full polysomnographic monitoring of respiratory and sleep variables. Arousals were scored using ASDA criteria. Hypopneas were scored when there was a 50% reduction in ventilation for > 10 seconds, associated with a 4% drop in oxygen saturation. For comparison, the ASDA arousal index in 16 normal subjects (without nasal CPAP) is provided. Results are given as mean +/- standard error of the mean. AHI was reduced from 55 +/- 3 to 1.5 +/- 0.35 events/hour (p < 0.0001). The arousal index was reduced from 65 +/- 3 to 18 +/- 2 events/hour (p < 0.0001), identical to the value in the 16 healthy normal subjects. There was a 158% +/- 21% increase in slow-wave sleep (p = 0.01) and a 186% +/- 27% increase in rapid eye movement sleep (p = 0.013). The AutoSet self-adjusting nasal CPAP system adequately treats obstructive sleep apnea syndrome on the first night under laboratory conditions.

  9. Delivery room continuous positive airway pressure and early pneumothorax in term newborn infants.

    Science.gov (United States)

    Clevenger, L; Britton, J R

    2017-01-01

    To assess the association between delivery room (DR) continuous positive airway pressure (CPAP) and pneumothorax (PT) in term newborns. Two studies performed in community hospitals used data extracted from computerized records of term newborns. Infants receiving positive pressure ventilation in the DR were excluded. Tabulated data included receipt of DR CPAP, PT on the day of birth, and gestational age (GA). In a case-control study from 2001-2013, infants with PT were compared to controls without PT but with respiratory distress or hypoxia persisting from birth for receipt of DR CPAP. In a cohort study from 2014-2016, infants receiving and not receiving DR CPAP were compared for the incidence of PT. In the case-control study, data were obtained for 169 cases and 850 controls. Compared to controls, PT infants were more likely to have received DR CPAP (16.8% vs. 40.2%, respectively, P CPAP (Adjusted Odds Ratio [AOR] = 3.30, 95% confidence interval [CI] = 2.31, 4.72, P CPAP and 4.8% of 228 infants receiving DR CPAP (P CPAP significantly predicted PT (OR = 59.59, 95% CI = 23.34, 147.12, P CPAP in delivery rooms are associated with increased risk of PT. A cause-and-effect relationship between CPAP and PT cannot be claimed in this study. Further research is needed to better understand this relationship.

  10. Pressure support ventilation vs Continuous positive airway pressure for treating of acute cardiogenic pulmonary edema: A pilot study.

    Science.gov (United States)

    Pagano, Antonio; Numis, Fabio G; Rosato, Valerio; Russo, Teresa; Porta, Giovanni; Bosso, Giorgio; Serra, Claudia; Masarone, Mario; Visone, Giuseppe; Paladino, Fiorella

    2018-04-24

    Non-invasive ventilation is usually adopted as a support to medical therapy in patients with acute pulmonary edema, but which modality between Pressure Support Ventilation (PSV) and Continuous Positive Airway Pressure (CPAP) has better favourable effects is not been yet well known. Aim of this observational study was to provide data on these different non-invasive ventilation modalities in the management of acute cardiogenic pulmonary edema. One-hundred-fifty-three patients consecutively admitted to the Emergency Room of two different Center were enrolled and randomly assigned to CPAP or PSV. Data relative to mortality, need of endotracheal intubation, sequential blood gas analysis were compared. Furthermore, there were no significant differences regarding mortality in the two groups, but patients treated with PSV had a significant lower rate of endotracheal intubation and a higher improvement of blood gas analyses parameters. In conclusion, our data support only a slight advantage in favour to PSV versus CPAP. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. The effect of continuous positive airway pressure on blood pressure in patients with obstructive sleep apnea syndrome

    Directory of Open Access Journals (Sweden)

    Giorgiana Dediu

    2017-12-01

    Full Text Available Introduction. Obstructive sleep apnea syndrome (OSAS is a disease with increasing prevalence nowadays, being associated with multiple cardiovascular diseases, such as arterial hypertension. The objective of the study was to evaluate the effect of continuous positive airway pressure (CPAP on blood pressure values. Materials and methods. We performed a prospective interventional study on 52 patients with obstructive sleep apnea syndrome. The patients were divided into 2 groups: Group A (who received both pharmacological and CPAP treatment and Group B (who received only pharmacological treatment, and were followed up at 3 and 6 months. The statistical analysis was made with SPSS and Microsoft Excel. At the same time, using the surrogate marker –RDW, we tried to evaluate the persistence of systemic inflammation, knowing that OSAS is associated with inflammation. Results. The systolic blood pressure values decreased at 6 months in all OSAS patients who have used CPAP, including patients with normal values of blood pressure. At the same time, the lack of OSAS treatment led to increased values of blood pressure by approximately 10 mmHg. We noticed a link between RDW, age and blood pressure values, respectively the increase of RDW and age may result in an increase in blood pressure. Conclusions. The OSAS treatment can decrease the blood pressure values. A higher RDW may be considered a negative prognostic factor for these patients, reflecting the role of systemic inflammation in the appearance of cardiovascular disorders.

  12. The effect of obstructive sleep apnea and treatment with continuous positive airway pressure on stroke rehabilitation: rationale, design and methods of the TOROS study

    NARCIS (Netherlands)

    Aaronson, J.A.; van Bennekom, C.A.M.; Hofman, W.F.; van Bezeij, T.; van den Aardweg, J.G.; Groet, E.; Kylstra, W.A.; Schmand, B.A.

    2014-01-01

    BACKGROUND: Obstructive sleep apnea is a common sleep disorder in stroke patients. Obstructive sleep apnea is associated with stroke severity and poor functional outcome. Continuous positive airway pressure seems to improve functional recovery in stroke rehabilitation. To date, the effect of

  13. Effects of continuous positive airway pressure on energy intake in obstructive sleep apnea: A pilot sham-controlled study

    OpenAIRE

    Shechter, Ari; Kovtun, Kyle; St-Onge, Marie-Pierre

    2016-01-01

    Obesity is among the leading risk factors for obstructive sleep apnea (OSA). A reciprocal relationship between obesity and OSA has been proposed, which may be due to excessive food intake. We conducted a pilot study to test the effects of continuous positive airway pressure (CPAP) on energy intake (EI) in OSA patients using a sham-controlled crossover design. In-laboratory total daily EI was assessed after 2 mo of active and sham CPAP. Four men were enrolled (age ± SEM: 51.8 ± 2.1 y; body mas...

  14. Routine use of humidification with nasal continuous positive airway pressure.

    Science.gov (United States)

    Worsnop, C J; Miseski, S; Rochford, P D

    2010-09-01

    Heated humidification can reduce nasal symptoms caused by continuous positive airway pressure (CPAP) treatment, but its routine use has not been studied over the medium term in a randomized controlled trial. The aim of this study is to determine if heated humidification would reduce nasal symptoms and improve adherence with CPAP treatment in all patients with sleep apnoea irrespective of whether they had nasal symptoms initially. A randomized, parallel group design. Patients were treated for 3 months with a Fisher & Paykel HC201 pump with built-in heated humidification, or with the heater disabled and without water. Adherence was measured with a timer built into the pumps. Nasal symptoms were measured with a 10-cm visual analogue scale. There were 25 in the humidification group and 29 in the non-humidification group. After 12 weeks mean (standard deviation) adherence with CPAP was 4.7 (2.4) and 4.5 (2.2) hours per night respectively. Nasal symptoms that were reduced were nose blocked* 6 (12), 18 (26); sneezing* 4 (8), 15 (25); dry nose* 8 (12), 24 (33); stuffy nose* 7 (14), 22(31); dry mouth* 13 (18), 33(36); and runny nose* 6 (17), 14 (29). Parameters marked with an asterisk '*' had P humidification with CPAP in all patients with sleep apnoea reduced nasal symptoms, but did not improve adherence. © 2010 The Authors. Internal Medicine Journal © 2010 Royal Australasian College of Physicians.

  15. Is the Relationship between Race and Continuous Positive Airway Pressure Adherence Mediated by Sleep Duration?

    Science.gov (United States)

    Billings, Martha E.; Rosen, Carol L.; Wang, Rui; Auckley, Dennis; Benca, Ruth; Foldvary-Schaefer, Nancy; Iber, Conrad; Zee, Phyllis; Redline, Susan; Kapur, Vishesh K.

    2013-01-01

    Study Objectives: Black race has been associated with decreased continuous positive airway pressure (CPAP) adherence. Short sleep duration, long sleep latency, and insomnia complaints may affect CPAP adherence as they affect sleep and opportunity to use CPAP. We assessed whether self-reported sleep measures were associated with CPAP adherence and if racial variations in these sleep characteristics may explain racial differences in CPAP adherence. Design: Analysis of data from a randomized controlled trial (HomePAP), which investigated home versus laboratory-based diagnosis and treatment of obstructive sleep apnea. Setting: Seven American Academy of Sleep Medicine-accredited sleep centers in five cities in the United States. Patients or Participants: Enrolled subjects (n = 191) with apnea-hypopnea index ≥ 15 and sleepiness (Epworth Sleepiness Scale > 12). Interventions: N/A. Measurements and Results: Multivariable regression was used to assess if subjective sleep measures and symptoms predicted 3-mo CPAP use. Mediation analysis was used to assess if sleep measures mediated the association of race with CPAP adherence. Black participants reported shorter sleep duration and longer sleep latency at baseline than white and Hispanic participants. Shorter sleep duration and longer sleep latency predicted worse CPAP adherence. Sleep duration mediated the association of black race with lower CPAP adherence. However, insomnia symptoms were not associated with race or CPAP adherence. Conclusions: Among subjects with similar severity of obstructive sleep apnea and sleepiness, baseline self-reported sleep duration and latency, but not perceived insomnia, predicted CPAP adherence over 3 mo. Sleep duration explains some of the observed differences in CPAP use by race. Sleep duration and latency should be considered when evaluating poor CPAP adherence. Clinical Trial Information: Portable Monitoring for Diagnosis and Management of Sleep Apnea (HomePAP) URL: http

  16. Effect of Continuous Positive Airway Pressure on Stroke Rehabilitation: A Pilot Randomized Sham-Controlled Trial

    Science.gov (United States)

    Khot, Sandeep P.; Davis, Arielle P.; Crane, Deborah A.; Tanzi, Patricia M.; Li Lue, Denise; Claflin, Edward S.; Becker, Kyra J.; Longstreth, W.T.; Watson, Nathaniel F.; Billings, Martha E.

    2016-01-01

    Study Objectives: Obstructive sleep apnea (OSA) predicts poor functional outcome after stroke and increases the risk for recurrent stroke. Less is known about continuous positive airway pressure (CPAP) treatment on stroke recovery. Methods: In a pilot randomized, double-blind, sham-controlled trial, adult stroke rehabilitation patients were assigned to auto-titrating or sham CPAP without diagnostic testing for OSA. Change in Functional Independence Measure (FIM), a measure of disability, was assessed between rehabilitation admission and discharge. Results: Over 18 months, 40 patients were enrolled and 10 withdrew from the study: 7 from active and 3 from sham CPAP (p > 0.10). For the remaining 30 patients, median duration of CPAP use was 14 days. Average CPAP use was 3.7 h/night, with at least 4 h nightly use among 15 patients. Adherence was not influenced by treatment assignment or stroke severity. In intention-to-treat analyses (n = 40), the median change in FIM favored active CPAP over sham but did not reach statistical significance (34 versus 26, p = 0.25), except for the cognitive component (6 versus 2.5, p = 0.04). The on-treatment analyses (n = 30) yielded similar results (total FIM: 32 versus 26, p = 0.11; cognitive FIM: 6 versus 2, p = 0.06). Conclusions: A sham-controlled CPAP trial among stroke rehabilitation patients was feasible in terms of recruitment, treatment without diagnostic testing and adequate blinding—though was limited by study retention and CPAP adherence. Despite these limitations, a trend towards a benefit of CPAP on recovery was evident. Tolerance and adherence must be improved before the full benefits of CPAP on recovery can be assessed in larger trials. Citation: Khot SP, Davis AP, Crane DA, Tanzi PM, Li Lue D, Claflin ES, Becker KJ, Longstreth WT, Watson NF, Billings ME. Effect of continuous positive airway pressure on stroke rehabilitation: a pilot randomized sham-controlled trial. J Clin Sleep Med 2016;12(7):1019–1026. PMID

  17. Continuous positive airway pressure and conventional mechanical ventilation in the treatment of meconium aspiration syndrome.

    Science.gov (United States)

    Goldsmith, J P

    2008-12-01

    Meconium aspiration syndrome (MAS) is a complex syndrome that ranges in severity from mild respiratory distress to severe respiratory failure, persistent pulmonary hypertension of the newborn and sometimes death. Understanding of the syndrome's complicated pathophysiology will help determine the appropriate treatment strategy, including the use of continuous positive airway pressure (CPAP), conventional mechanical ventilation (CMV) and other therapies. Approximately 30 to 50% of infants diagnosed with MAS will require CPAP or mechanical ventilation. The optimum modes of ventilation for MAS are not known. Very few studies have been conducted to determine 'best' ventilatory strategies. Despite the introduction, over the last two decades, of innovative ventilatory treatments for this disease (for example, surfactant, high-frequency ventilation, inhaled nitric oxide, extracorporeal membrane oxygenation), the majority of infants can be successfully managed with CPAP or mechanical ventilation alone.

  18. Cardiovascular risk in patients with sleep apnoea with or without continuous positive airway pressure therapy

    DEFF Research Database (Denmark)

    Lamberts, Morten; Nielsen, O W; Lip, G Y H

    2014-01-01

    BACKGROUND: The prognostic significance of age and continuous positive airway pressure (CPAP) therapy on cardiovascular disease in patients with sleep apnoea has not been assessed previously. METHODS: Using nationwide databases, the entire Danish population was followed from 2000 until 2011. First......-time sleep apnoea diagnoses and use of CPAP therapy were determined. Incidence rate ratios (IRRs) of ischaemic stroke and myocardial infarction (MI) were analysed using Poisson regression models. RESULTS: Amongst 4.5 million individuals included in the study, 33 274 developed sleep apnoea (mean age 53, 79......% men) of whom 44% received persistent CPAP therapy. Median time to initiation of CPAP therapy was 88 days (interquartile range 34-346). Patients with sleep apnoea had more comorbidities compared to the general population. Crude rates of MI and ischaemic stroke were increased for sleep apnoea patients...

  19. Early surfactant therapy and nasal continuous positive airways ...

    African Journals Online (AJOL)

    respiratory distress syndrome (RDS) receiving nasal continuous positive airways ... required FiO2 was allowed to rise above 0.4 before surfactant was administered. ... group received surfactant immediately and the high-threshold group ...

  20. A 64-year old man who sustained many episodes of acute cardiogenic pulmonary edema successfully treated with Boussignac continuous positive airway pressure : A case report

    NARCIS (Netherlands)

    Dieperink, Willem; van der Horst, Iwan C. C.; Nannenberg-Koops, Jaqueline W.; Brouwer, Henk W.; Jaarsma, T.; Nieuwland, Wybe; Zijlstra, Felix; Nijsten, Maarten W. N.

    2007-01-01

    Continuous positive airway pressure (CPAP) is standard treatment for patients with acute cardiogenic pulmonary edema. We describe a patient who had 21 episodes of acute cardiogenic pulmonary edema due to very poor patient compliance. This 64-year old man had end-stage congestive heart failure based

  1. Verifying the Relative Efficacy between Continuous Positive Airway Pressure Therapy and Its Alternatives for Obstructive Sleep Apnea: A Network Meta-analysis

    Directory of Open Access Journals (Sweden)

    Tingwei Liu

    2017-06-01

    Full Text Available Obstructive sleep apnea (OSA is a common breathing disorder, and continuous positive airway pressure (CPAP therapy together with its alternatives has been developed to treat this disease. This network meta-analysis (NMA was aimed to compare the efficacy of treatments for OSA. Cochrane Library, MEDLINE, and Embase were searched for eligible studies. A conventional and NMA was carried out to compare all therapies. Sleeping characteristics, including Apnea–Hypopnea Index (AHI, Epworth Sleepiness Scale (ESS, arterial oxygen saturation, and arousal index (AI, and changes of blood pressure were selected as outcomes. A total of 84 studies were finally included after rigorous screenings. For the primary outcomes of AHI and ESS, the value of auto-adjusting positive airway pressure (APAP, CPAP, and oral appliance (OA all showed statistically reduction compared with inactive control (IC. Similar observation was obtained in AI, with treatments of the three active interventions. A lower effect of IC in SaO2 was exhibited when compared with APAP, CPAP, and OA. Similar statistically significant results were presented in 24 h systolic blood pressure and 24 h DBP when comparing with CPAP. Our NMA identified CPAP as the most efficacious treatment for OSA patients after the evaluation of sleeping characteristics and blood pressures. In addition, more clinical trials are needed for further investigation due to the existence of inconsistency observed in this study.

  2. Insomnia complaints in lean patients with obstructive sleep apnea negatively affect positive airway pressure treatment adherence.

    Science.gov (United States)

    Eysteinsdottir, Bjorg; Gislason, Thorarinn; Pack, Allan I; Benediktsdottir, Bryndís; Arnardottir, Erna S; Kuna, Samuel T; Björnsdottir, Erla

    2017-04-01

    The objective of this study was to evaluate the determinants of long-term adherence to positive airway pressure treatment among patients with obstructive sleep apnea, with special emphasis on patients who stop positive airway pressure treatment within 1 year. This is a prospective long-term follow-up of subjects in the Icelandic Sleep Apnea Cohort who were diagnosed with obstructive sleep apnea between 2005 and 2009, and started on positive airway pressure treatment. In October 2014, positive airway pressure adherence was obtained by systematically evaluating available clinical files (n = 796; 644 males, 152 females) with moderate to severe obstructive sleep apnea (apnea-hypopnea index ≥15 events per h). The mean follow-up time was 6.7 ± 1.2 years. In total, 123 subjects (15.5%) returned their positive airway pressure device within the first year, 170 (21.4%) returned it later and 503 (63.2%) were still using positive airway pressure. The quitters within the first year had lower body mass index, milder obstructive sleep apnea, less sleepiness, and more often had symptoms of initial and late insomnia compared with long-term positive airway pressure users at baseline. Both initial and late insomnia were after adjustment still significantly associated with being an early quitter among subjects with body mass index insomnia are associated with early quitting on positive airway pressure among non-obese subjects. © 2016 European Sleep Research Society.

  3. Continuous Positive Airway Pressure Device Time to Procurement in a Disadvantaged Population

    Directory of Open Access Journals (Sweden)

    Lourdes M. DelRosso

    2015-01-01

    Full Text Available Introduction. The management of obstructive sleep apnea (OSA in patients who cannot afford a continuous positive airway pressure (CPAP device is challenging. In this study we compare time to CPAP procurement in three groups of patients diagnosed with OSA: uninsured subsidized by a humanitarian grant (Group 1, uninsured unsubsidized (Group 2, and those with Medicare or Medicaid (Group 3. We evaluate follow-up and adherence in Group 1. We hypothesize that additional factors, rather than just the ability to obtain CPAP, may uniquely affect follow-up and adherence in uninsured patients. Methods. 30 patients were in Groups 1 and 2, respectively. 12 patients were in Group 3. Time of CPAP procurement from OSA diagnosis to CPAP initiation was assessed in all groups. CPAP adherence data was collected for Group 1 patients at 1, 3, 6, and 9 months. Results. There were no significant differences between groups in gender, age, body mass index, or apnea hypopnea index. The mean time to procurement in Group 1 was shorter compared to Group 2 but not significant. Compared to both Group 1 and Group 2, Group 3 patients had significantly shorter times to device procurement. Conclusion. Time to procurement of CPAP was significantly shorter in those with Medicaid/Medicare insurance compared to the uninsured.

  4. Experience of nasal continuous positive airway pressure (cpap) by infant flow driver in a neonatal unit of a developing country

    International Nuclear Information System (INIS)

    Iqbal, A.; Waqar, T.; Safdar, C.A.; Iqbal, T.

    2014-01-01

    Objective: To study the safety and efficacy of nasal continuous positive airways pressure by infant flow drivers in neonates admitted with respiratory problems. Study Design: Quasi-experimental study. Place and Duration of Study: This study was conducted at CMH Lahore from April 2012 to March 2013. Subjects and Methods: All infants who were treated with nasal continuous positive airway pressure (nCPAP) for various indications at neonatal intensive care unit (NICU) of CMH Lahore were evaluated for gestational, age, weight, gender, indications and duration on nCPAP, pre-defined outcomes, complications and length of hospital stay. Efficacy was defined as the ability to manage an infant on nCPAP alone thus avoiding the need for mechanical ventilation. Results: During the study period, 343 neonates were admitted in NICU, forty five neonates were placed on nCPAP. Mean gestational age was 33.85+ 3 weeks. Mean weight was 2043 + 770 grams. Main indications for applying nCPAP were respiratory distress syndrome (48.9%) and neonatal pneumonia (17.8%). Most common complication was abdominal distension (6.7%). Out of 45 infants placed on nCPAP, 32 (71.1%) were managed on nCPAP alone while 13 (28.9%) needed mechanical ventilation after nCPAP failure. Conclusion: Nasal CPAP by an infant flow driver is a useful method to manage respiratory distress in neonates. It reduces the need for mechanical ventilation and can be used as first line respiratory support before mechanical ventilation. (author)

  5. Clinical predictors of central sleep apnea evoked by positive airway pressure titration.

    Science.gov (United States)

    Moro, Marilyn; Gannon, Karen; Lovell, Kathy; Merlino, Margaret; Mojica, James; Bianchi, Matt T

    2016-01-01

    Treatment-emergent central sleep apnea (TECSA), also called complex apnea, occurs in 5%-15% of sleep apnea patients during positive airway pressure (PAP) therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management. We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split-night; n=306 two-night). Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG) data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI) ≥5 during split-night PSG (SN-PSG) versus full-night PSG (FN-PSG) titrations. CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients. Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the laboratory setting, even as PSG remains the gold standard for characterizing primary central apnea and TECSA.

  6. Continuous Positive Airway Pressure During Exercise Improves Walking Time in Patients Undergoing Inpatient Cardiac Rehabilitation After Coronary Artery Bypass Graft Surgery: A RANDOMIZED CONTROLLED TRIAL.

    Science.gov (United States)

    Pantoni, Camila Bianca Falasco; Di Thommazo-Luporini, Luciana; Mendes, Renata Gonçalves; Caruso, Flávia Cristina Rossi; Mezzalira, Daniel; Arena, Ross; Amaral-Neto, Othon; Catai, Aparecida Maria; Borghi-Silva, Audrey

    2016-01-01

    Continuous positive airway pressure (CPAP) has been used as an effective support to decrease the negative pulmonary effects of coronary artery bypass graft (CABG) surgery. However, it is unknown whether CPAP can positively influence patients undergoing CABG during exercise. This study evaluated the effectiveness of CPAP on the first day of ambulation after CABG in patients undergoing inpatient cardiac rehabilitation (CR). Fifty-four patients after CABG surgery were randomly assigned to receive either inpatient CR and CPAP (CPG) or standard CR without CPAP (CG). Cardiac rehabilitation included walking and CPAP pressures were set between 10 to 12 cmH2O. Participants were assessed on the first day of walking at rest and during walking. Outcome measures included breathing pattern variables, exercise time in seconds (ETs), dyspnea/leg effort ratings, and peripheral oxygen saturation (SpO2). Twenty-seven patients (13 CPG vs 14 CG) completed the study. Compared with walking without noninvasive ventilation assistance, CPAP increased ETs by 43.4 seconds (P = .040) during walking, promoted better thoracoabdominal coordination, increased ventilation during walking by 12.5 L/min (P = .001), increased SpO2 values at the end of walking by 2.6% (P = .016), and reduced dyspnea ratings by 1 point (P = .008). Continuous positive airway pressure can positively influence exercise tolerance, ventilatory function, and breathing pattern in response to a single bout of exercise after CABG.

  7. Type of mask may impact on continuous positive airway pressure adherence in apneic patients.

    Directory of Open Access Journals (Sweden)

    Jean Christian Borel

    Full Text Available RATIONALE: In obstructive sleep apnea patients (OSA, continuous positive airway pressure (CPAP adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. OBJECTIVE: To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. METHODS: Newly CPAP treated OSA participating in "Observatoire Sommeil de la Fédération de Pneumologie", a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. RESULTS: 2311 OSA (age = 57(12 years, apnea+hypopnea index = 41(21/h, 29% female were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5, depression, low effective pressure, and side effects. CONCLUSION: As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed.

  8. Type of mask may impact on continuous positive airway pressure adherence in apneic patients.

    Science.gov (United States)

    Borel, Jean Christian; Tamisier, Renaud; Dias-Domingos, Sonia; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Muir, Jean François; Levy, Patrick; Series, Frederic; Pepin, Jean-Louis

    2013-01-01

    In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. Newly CPAP treated OSA participating in "Observatoire Sommeil de la Fédération de Pneumologie", a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed.

  9. Asthma outcomes improve with continuous positive airway pressure for obstructive sleep apnea.

    Science.gov (United States)

    Serrano-Pariente, J; Plaza, V; Soriano, J B; Mayos, M; López-Viña, A; Picado, C; Vigil, L

    2017-05-01

    Continuous positive airway pressure (CPAP) in asthma patients with concomitant obstructive sleep apnea syndrome (OSAS) seems to have a favorable impact on asthma, but data are inconsistent due to methodological limitations of previous studies. Prospective, multicenter study. We examined asthma outcomes after 6 months of CPAP in 99 adult asthma patients (mean age 57 years) with OSAS (respiratory disturbance index ≥20). Asthma control and quality of life were assessed with the Asthma Control Questionnaire (ACQ) and the Mini Asthma Quality of Life Questionnaire (MiniAQLQ), respectively. Data were analyzed by intention-to-treat basis. The mean ± SD score of the ACQ decreased from 1.39 ± 0.91 at baseline to 1.0 ± 0.78 at 6 months (P = 0.003), the percentage of patients with uncontrolled asthma from 41.4% to 17.2% (P = 0.006), and the percentage of patients with asthma attacks in the 6 months before and after treatment from 35.4% to 17.2% (P = 0.015). The score of the mAQLQ increased from 5.12 ± 1.38 to 5.63 ± 1.17 (P = 0.009). There were also significant improvements in symptoms of gastroesophageal reflux and rhinitis, bronchial reversibility, and exhaled nitric oxide values (all P obstructive sleep apnea syndrome. © 2016 The Authors. Allergy published by John Wiley & Sons Ltd.

  10. Comparison of nasal continuous positive airway pressure delivered by seven ventilators using simulated neonatal breathing.

    Science.gov (United States)

    Drevhammar, Thomas; Nilsson, Kjell; Zetterström, Henrik; Jonsson, Baldvin

    2013-05-01

    Nasal continuous positive airway pressure (NCPAP) is an established treatment for respiratory distress in neonates. Most modern ventilators are able to provide NCPAP. There have been no large studies examining the properties of NCPAP delivered by ventilators. The aim of this study was to compare pressure stability and imposed work of breathing (iWOB) for NCPAP delivered by ventilators using simulated neonatal breathing. Experimental in vitro study. Research laboratory in Sweden. None. Neonatal breathing was simulated using a mechanical lung simulator. Seven ventilators were tested at different CPAP levels using two breath profiles. Pressure stability and iWOB were determined. Results from three ventilators revealed that they provided a slight pressure support. For these ventilators, iWOB could not be calculated. There were large differences in pressure stability and iWOB between the tested ventilators. For simulations using the 3.4-kg breath profile, the pressure swings around the mean pressure were more than five times greater, and iWOB more than four times higher, for the system with the highest measured values compared with the system with the lowest. Overall, the Fabian ventilator was the most pressure stable system. Evita XL and SERVO-i were found more pressure stable than Fabian in some simulations. The results for iWOB were in accordance with pressure stability for systems that allowed determination of this variable. Some of the tested ventilators unexpectedly provided a minor degree of pressure support. In terms of pressure stability, we have not found any advantages of ventilators as a group compared with Bubble CPAP, Neopuff, and variable flow generators that were tested in our previous study. The variation between individual systems is great within both categories. The clinical importance of these findings needs further investigation.

  11. Financial Analysis of an Intensive Pediatric Continuous Positive Airway Pressure Program.

    Science.gov (United States)

    Riley, E Brooks; Fieldston, Evan S; Xanthopoulos, Melissa S; Beck, Suzanne E; Menello, Mary Kate; Matthews, Edward; Marcus, Carole L

    2017-02-01

    Continuous positive airway pressure (CPAP) is effective in treating obstructive sleep apnea in children, but adherence to therapy is low. Our center created an intensive program that aimed to improve adherence. Our objective was to estimate the program's efficacy, cost, revenue and break-even point in a generalizable manner relative to a standard approach. The intensive program included device consignment, behavioral psychology counseling, and follow-up telephone calls. Economic modeling considered the costs, revenue and break-even point. Costs were derived from national salary reports and the Pediatric Health Information System. The 2015 Medicare reimbursement schedule provided revenue estimates. Prior to the intensive CPAP program, only 67.6% of 244 patients initially prescribed CPAP appeared for follow-up visits and only 38.1% had titration polysomnograms. In contrast, 81.4% of 275 patients in the intensive program appeared for follow-up visits (p break-even points would need to be 1.29-2.08 times higher to cover the costs. An intensive CPAP program leads to substantially higher follow-up and CPAP titration rates, but costs are higher. While affordable at our institution due to the local payer mix and revenue, Medicare reimbursement levels would not cover estimated costs. This study highlights the need for enhanced funding for pediatric CPAP programs, due to the special needs of this population and the long-term health risks of suboptimally treated obstructive sleep apnea. © Sleep Research Society 2016. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  12. Randomized controlled trial comparing nasal intermittent positive pressure ventilation and nasal continuous positive airway pressure in premature infants after tracheal extubation

    Directory of Open Access Journals (Sweden)

    Daniela Franco Rizzo Komatsu

    Full Text Available Summary Objective: To analyze the frequency of extubation failure in premature infants using conventional mechanical ventilation (MV after extubation in groups subjected to nasal intermittent positive pressure ventilation (nIPPV and continuous positive airway pressure (nCPAP. Method: Seventy-two premature infants with respiratory failure were studied, with a gestational age (GA ≤ 36 weeks and birth weight (BW > 750 g, who required tracheal intubation and mechanical ventilation. The study was controlled and randomized in order to ensure that the members of the groups used in the research were chosen at random. Randomization was performed at the time of extubation using sealed envelopes. Extubation failure was defined as the need for re-intubation and mechanical ventilation during the first 72 hours after extubation. Results: Among the 36 premature infants randomized to nIPPV, six (16.6% presented extubation failure in comparison to 11 (30.5% of the 36 premature infants randomized to nCPAP. There was no statistical difference between the two study groups regarding BW, GA, classification of the premature infant, and MV time. The main cause of extubation failure was the occurrence of apnea. Gastrointestinal and neurological complications did not occur in the premature infants participating in the study. Conclusion: We found that, despite the extubation failure of the group of premature infants submitted to nIPPV being numerically smaller than in premature infants submitted to nCPAP, there was no statistically significant difference between the two modes of ventilatory support after extubation.

  13. Auto-titrating versus fixed continuous positive airway pressure for the treatment of obstructive sleep apnea: a systematic review with meta-analyses

    Directory of Open Access Journals (Sweden)

    Ip Stanley

    2012-03-01

    Full Text Available Abstract Background Obstructive sleep apnea is a relatively common disorder that can lead to lost productivity and cardiovascular disease. The form of positive airway treatment that should be offered is unclear. Methods MEDLINE and the Cochrane Central Trials registry were searched for English language randomized controlled trials comparing auto-titrating positive airway pressure (APAP with continuous positive airway pressure (CPAP in adults with obstructive sleep apnea (inception through 9/2010. Six researchers extracted information on study design, potential bias, patient characteristics, interventions and outcomes. Data for each study were extracted by one reviewer and confirmed by another. Random effects model meta-analyses were performed for selected outcomes. Results Twenty-four randomized controlled trials met the inclusion criteria. In individual studies, APAP and fixed CPAP resulted in similar changes from baseline in the apnea-hypopnea index, most other sleep study measures and quality of life. By meta-analysis, APAP improved compliance by 11 minutes per night (95% CI, 3 to 19 minutes and reduced sleepiness as measured by the Epworth Sleepiness Scale by 0.5 points (95% CI, 0.8 to 0.2 point reduction compared with fixed CPAP. Fixed CPAP improved minimum oxygen saturation by 1.3% more than APAP (95% CI, 0.4 to 2.2%. Studies had relatively short follow-up and generally excluded patients with significant comorbidities. No study reported on objective clinical outcomes. Conclusions Statistically significant differences were found but clinical importance is unclear. Because the treatment effects are similar between APAP and CPAP, the therapy of choice may depend on other factors such as patient preference, specific reasons for non-compliance and cost.

  14. Continuous positive airway pressure (CPAP after lung resection: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Ligia dos Santos Roceto

    Full Text Available CONTEXT AND OBJECTIVE: Noninvasive mechanical ventilation during the postoperative period (PO following lung resection can restore residual functional capacity, improve oxygenation and spare the inspiratory muscles. The objective of this study was to assess the efficacy of continuous positive airway pressure (CPAP associated with physiotherapy, compared with physiotherapy alone after lung resection. DESIGN AND SETTING: Open randomized clinical trial conducted in the clinical hospital of Universidade Estadual de Campinas. METHOD: Sessions were held in the immediate postoperative period (POi and on the first and second postoperative days (PO1 and PO2, and the patients were reassessed on the discharge day. CPAP was applied for two hours and the pressure adjustment was set between 7 and 8.5 cmH2O. The oxygenation index (OI, Borg scale, pain scale and presence of thoracic drains and air losses were evaluated. RESULTS : There was a significant increase in the OI in the CPAP group in the POi compared to the Chest Physiotherapy (CP group, P = 0.024. In the CP group the OI was significantly lower on PO1 (P = 0,042, than CPAP group. The air losses were significantly greater in the CPAP group in the POi and on PO1 (P = 0.001, P = 0.028, but there was no significant difference between the groups on PO2 and PO3. There was a statistically significant difference between the groups regarding the Borg scale in the POi (P < 0.001, but there were no statistically significant differences between the groups regarding the pain score. CONCLUSION: CPAP after lung resection is safe and improves oxygenation, without increasing the air losses through the drains. CLINICAL TRIAL REGISTRATION: NCT01285648

  15. Continuous positive airway pressure (CPAP) to treat respiratory distress in newborns in low- and middle-income countries.

    Science.gov (United States)

    Dewez, Juan Emmanuel; van den Broek, Nynke

    2017-01-01

    Severe respiratory distress is a serious complication common to the three major causes of neonatal mortality and morbidity (prematurity, intra-partum-related hypoxia and infections). In low- and middle-income countries (LMICs), 20% of babies presenting with severe respiratory distress die.Continuous positive airway pressure (CPAP), is an effective intervention for respiratory distress in newborns and widely used in high-income countries. Following the development of simple, safe and relatively inexpensive CPAP devices, there is potential for large-scale implementation in the developing world.In this article, we describe existing CPAP systems and present a review of the current literature examining the effectiveness of CPAP compared to standard care (oxygen) in newborns with respiratory distress. We also discuss the evidence gap which needs to be addressed prior to its integration into health systems in LMICs. © The Author(s) 2016.

  16. [Intraabdominal fat redistribution in long-term continuous positive airway pressure treatment in obstructive sleep apnea patients].

    Science.gov (United States)

    Català, Raquel; Ferré, Raimón; Sangenís, Sandra; Cabré, Anna; Hernández-Flix, Salvador; Masana, Lluís

    2016-06-03

    Obesity is the main risk factor for obstructive sleep apnoea (OSA). The aim was to evaluate the long-term effect of continuous positive airway pressure (CPAP) on intraabdominal fat distribution in OSA patients. Fifty OSA patients with and 35 without CPAP treatment criteria were followed-up for 2 years. Visceral and subcutaneous adipose tissue (VAT and SAT) and preaortic intraabdominal fat (PIF) were assessed by sonography. In the non CPAP treated group, SAT and VAT mean values didn't change, while a significantly PIF growth was observed (55.19 [23.44] vs. 63.45 [23.94] mm, P=.021). In the CPAP treated group, VAT and PIF mean were not changed, while SAT decreased significantly (11.29 [5.69] vs. 10.47 [5.71] mm, P=.012). Long-term CPAP treatment produces intraabdominal fat redistribution and is associated with an anthropometric profile of lower cardiovascular risk in OSA patients. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  17. Airway pressure release ventilation and biphasic positive airway pressure: a systematic review of definitional criteria.

    Science.gov (United States)

    Rose, Louise; Hawkins, Martyn

    2008-10-01

    The objective of this study was to identify the definitional criteria for the pressure-limited and time-cycled modes: airway pressure release ventilation (APRV) and biphasic positive airway pressure (BIPAP) available in the published literature. Systematic review. Medline, PubMed, Cochrane, and CINAHL databases (1982-2006) were searched using the following terms: APRV, BIPAP, Bilevel and lung protective strategy, individually and in combination. Two independent reviewers determined the paper eligibility and abstracted data from 50 studies and 18 discussion articles. Of the 50 studies, 39 (78%) described APRV, and 11 (22%) described BIPAP. Various study designs, populations, or outcome measures were investigated. Compared to BIPAP, APRV was described more frequently as extreme inverse inspiratory:expiratory ratio [18/39 (46%) vs. 0/11 (0%), P = 0.004] and used rarely as a noninverse ratio [2/39 (5%) vs. 3/11 (27%), P = 0.06]. One (9%) BIPAP and eight (21%) APRV studies used mild inverse ratio (>1:1 to branding may further add to confusion. Generic naming of modes and consistent definitional parameters may improve consistency of patient response for a given mode and assist with clinical implementation.

  18. Optimal level of continuous positive airway pressure: auto-adjusting titration versus titration with a predictive equation.

    Science.gov (United States)

    Choi, Ji Ho; Jun, Young Joon; Oh, Jeong In; Jung, Jong Yoon; Hwang, Gyu Ho; Kwon, Soon Young; Lee, Heung Man; Kim, Tae Hoon; Lee, Sang Hag; Lee, Seung Hoon

    2013-05-01

    The aims of the present study were twofold. We sought to compare two methods of titrating the level of continuous positive airway pressure (CPAP) - auto-adjusting titration and titration using a predictive equation - with full-night manual titration used as the benchmark. We also investigated the reliability of the two methods in patients with obstructive sleep apnea syndrome (OSAS). Twenty consecutive adult patients with OSAS who had successful, full-night manual and auto-adjusting CPAP titration participated in this study. The titration pressure level was calculated with a previously developed predictive equation based on body mass index and apnea-hypopnea index. The mean titration pressure levels obtained with the manual, auto-adjusting, and predictive equation methods were 9.0 +/- 3.6, 9.4 +/- 3.0, and 8.1 +/- 1.6 cm H2O,respectively. There was a significant difference in the concordance within the range of +/- 2 cm H2O (p = 0.019) between both the auto-adjusting titration and the titration using the predictive equation compared to the full-night manual titration. However, there was no significant difference in the concordance within the range of +/- 1 cm H2O (p > 0.999). When compared to full-night manual titration as the standard method, auto-adjusting titration appears to be more reliable than using a predictive equation for determining the optimal CPAP level in patients with OSAS.

  19. Clinical predictors of central sleep apnea evoked by positive airway pressure titration

    Directory of Open Access Journals (Sweden)

    Moro M

    2016-07-01

    Full Text Available Marilyn Moro,1 Karen Gannon,1 Kathy Lovell,1 Margaret Merlino,1 James Mojica,2 Matt T Bianchi,1,3 1Neurology Department, 2Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, MA, USA; 3Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA Purpose: Treatment-emergent central sleep apnea (TECSA, also called complex apnea, occurs in 5%–15% of sleep apnea patients during positive airway pressure (PAP therapy, but the clinical predictors are not well understood. The goal of this study was to explore possible predictors in a clinical sleep laboratory cohort, which may highlight those at risk during clinical management.Methods: We retrospectively analyzed 728 patients who underwent PAP titration (n=422 split night; n=306 two-night. Demographics and self-reported medical comorbidities, medications, and behaviors as well as standard physiological parameters from the polysomnography (PSG data were analyzed. We used regression analysis to assess predictors of binary presence or absence of central apnea index (CAI ≥5 during split PSG (SN-PSG versus full-night PSG (FN-PSG titrations.Results: CAI ≥5 was present in 24.2% of SN-PSG and 11.4% of FN-PSG patients during titration. Male sex, maximum continuous positive airway pressure, and use of bilevel positive airway pressure were predictors of TECSA, and rapid eye movement dominance was a negative predictor, for both SN-PSG and FN-PSG patients. Self-reported narcotics were a positive predictor of TECSA, and the time spent in stage N2 sleep was a negative predictor only for SN-PSG patients. Self-reported history of stroke and the CAI during the diagnostic recording predicted TECSA only for FN-PSG patients.Conclusion: Clinical predictors of treatment-evoked central apnea spanned demographic, medical history, sleep physiology, and titration factors. Improved predictive models may be increasingly important as diagnostic and therapeutic modalities move away from the

  20. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update

    Directory of Open Access Journals (Sweden)

    Johnson KG

    2015-10-01

    Full Text Available Karin Gardner Johnson, Douglas Clark Johnson Department of Medicine, Baystate Medical Center, Springfield, MA, USA Abstract: Many types of positive airway pressure (PAP devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features. Keywords: BiPAP, CPAP, iVAPS, AVAPS, ASV, positive pressure respiration, instrumentation, treatment algorithm

  1. Effect of different levels of continuous positive airway pressure on the 99mTc-DTPA lung clearance

    Directory of Open Access Journals (Sweden)

    Dulciane Nunes Paiva

    2014-04-01

    Full Text Available Backgound and Objectives: Positive airway pressure continues (CPAP produces significant hemodynamic changes that may influence the variability of breathing pattern and heart rate, acting as an additional therapy to prevent atelectasis and to combat hypoxia. The rate of inhaled 99 m Technetiumdiethylenetriaminepentaacetic acid (99mTc-DTPA, along with changes in the lung epithelium cause an increase in the rate of clearance of this compound. The aim of this study was evaluate the pulmonary clearance rate of 99mTechnetium Diethylenetriaminepentaacetic acid (99mTc-DTPA through the use of different levels of CPAP. Methods: It was a quasi-experimental study involving 17 healthy individuals with normal lung functional. 99mTc-DTPA, as aerosol, was nebulized for 3 minutes with the individual in a sitting position. The pulmonary clearance rate was assessed through pulmonary scintigraphy under spontaneous breathing and under 20 and 10 cmH2 O CPAP in the sitting position. The clearance rate was expressed as the half-time (T½ that is the time for the activity to decrease to 50% of the peak value. Results: 20 cmH2 O CPAP produced significant reduction of the T½ of 99mTc-DTPA in the sitting position (p=0.005. However, 10 cmH2 O CPAP did not alter the T½ of DTPA in the same positions. Conclusion: High levels of continuos positive pressure in normal lungs resulted in faster 99mTc-DTPA clearance moreover, 10 cmH2 O did not alter its clearance rate. KEYWORDS: Noninvasive ventilation. Technetium Tc 99m Pentetate. Radionuclide Imaging.

  2. Treatment of sleep-disordered breathing with positive airway pressure devices: technology update.

    Science.gov (United States)

    Johnson, Karin Gardner; Johnson, Douglas Clark

    2015-01-01

    Many types of positive airway pressure (PAP) devices are used to treat sleep-disordered breathing including obstructive sleep apnea, central sleep apnea, and sleep-related hypoventilation. These include continuous PAP, autoadjusting CPAP, bilevel PAP, adaptive servoventilation, and volume-assured pressure support. Noninvasive PAP has significant leak by design, which these devices adjust for in different manners. Algorithms to provide pressure, detect events, and respond to events vary greatly between the types of devices, and vary among the same category between companies and different models by the same company. Many devices include features designed to improve effectiveness and patient comfort. Data collection systems can track compliance, pressure, leak, and efficacy. Understanding how each device works allows the clinician to better select the best device and settings for a given patient. This paper reviews PAP devices, including their algorithms, settings, and features.

  3. Determinants of compliance with nasal continuous positive airway pressure treatment applied in a community setting.

    Science.gov (United States)

    Ball, E M.; Banks, M B.

    2001-05-01

    Objectives: To assess determinants of nasal continuous positive airway pressure (CPAP) compliance when applied in a community setting.Background: One-third of obstructive sleep apnea patients eventually refuse CPAP therapy. Treatment outcomes may be improved by identifying predictors of CPAP failure, including whether management by primary care physicians without sleep consultation affects results.Methods: Polysomnogram, chart review, and questionnaire results for regular CPAP users (n=123) were compared with those returning the CPAP machine (n=26).Results: Polysomnographic data and the presence of multiple sleep disorders were only modestly predictive of CPAP compliance. Striking differences in questionnaire responses separated CPAP users from non-users, who reported less satisfaction with all phases of their diagnosis and management. Rates of CPAP use were not significantly different between patients managed solely by their primary care physician or by a sleep consultant.Conclusions: Polysomnographic findings are unlikely to identify eventual CPAP non-compliers in a cost-effective fashion. Improvements in sleep apnea management may result from addressing the role of personality factors and multiple sleep disorders in determining compliance. In this practice setting, management by primary care physicians did not significantly degrade CPAP compliance.

  4. Oral appliance therapy versus nasal continuous positive airway pressure in obstructive sleep apnoea syndrome: a randomised, placebo-controlled trial on self-reported symptoms of common sleep disorders and sleep-related problems

    NARCIS (Netherlands)

    Nikolopoulou, M.; Byraki, A.; Ahlberg, J.; Heymans, M. W.; Hamburger, H. L.; de Lange, J.; Lobbezoo, F.; Aarab, G.

    2017-01-01

    Obstructive sleep apnoea syndrome (OSAS) is associated with several sleep disorders and sleep-related problems. Therefore, the aim of this study was to compare the effects of a mandibular advancement device (MAD) with those of nasal continuous positive airway pressure (nCPAP) on self-reported

  5. Development and evaluation of a self-efficacy instrument for Japanese sleep apnea patients receiving continuous positive airway pressure treatment

    Directory of Open Access Journals (Sweden)

    Saito A

    2015-01-01

    Full Text Available Ayako Saito,1 Shigeko Kojima,2 Fumihiko Sasaki,3 Masamichi Hayashi,4 Yuki Mieno,4 Hiroki Sakakibara,5 Shuji Hashimoto1 1Department of Hygiene, School of Medicine, Fujita Health University, Toyoake, Japan; 2Department of Rehabilitation, Faculty of Health Sciences, Nihon Fukushi University, Handa, Japan; 3SDB Research Laboratory, Takaoka Clinic, Nagoya, Japan; 4Department of Internal Medicine, Division of Respiratory Medicine and Clinical Allergy, Fujita Health University, Toyoake, Japan; 5Tokushige Kokyuki Clinic, Nagoya, Japan Abstract: The purpose of this study was to develop and evaluate a self-efficacy instrument for Japanese obstructive sleep apnea (OSA patients treated with continuous positive airway pressure (CPAP. Analyzed subjects were 653 Japanese OSA patients (619 males and 34 females treated with CPAP at a sleep laboratory in a respiratory clinic in a Japanese city. Based on Bandura's social cognitive theory, the CPAP Self-Efficacy Questionnaire for Sleep Apnea in Japanese (CSESA-J was developed by a focus group of experts, using a group interview of OSA patients for the items of two previous self-efficacy scales for Western sleep apnea patients receiving CPAP treatment. CSESA-J has two subscales, one for self-efficacy and the other for outcome expectancy, and consists of a total of 15 items. Content validity was confirmed by the focus group. Confirmatory factor analysis showed that the factor loadings of self-efficacy and outcome expectancy were 0.47–0.76 and 0.41–0.92, respectively, for the corresponding items. CSESA-J had a significant but weak positive association with the General Self-Efficacy Scale, and a strong positive association with “Self-efficacy scale on health behavior in patients with chronic disease.” Cronbach’s alpha coefficient was 0.85 for the self-efficacy subscale and 0.89 for the outcome expectancy subscale. The intraclass correlation coefficient using data from the first and second measurements with

  6. The effect of positive and negative message framing on short term continuous positive airway pressure compliance in patients with obstructive sleep apnea.

    Science.gov (United States)

    Pengo, Martino F; Czaban, Marcin; Berry, Marc P; Nirmalan, Prajeshan; Brown, Richard; Birdseye, Adam; Woroszyl, Asia; Chapman, Julia; Kent, Brian D; Hart, Nicholas; Rossi, Gian Paolo; Steier, Joerg

    2018-01-01

    Continuous positive airway pressure (CPAP), the best available treatment for obstructive sleep apnea (OSA), requires long-term compliance to be effective. Behavioral interventions may be used to improve adherence to CPAP. We aimed to investigate whether positive or negative message framing impacts on CPAP compliance in patients with OSA, when compared to standard care. Consenting patients with confirmed OSA were randomly allocated to receive along with their CPAP either positively or negatively framed messages (Pos; Neg), or standard care (Con). Standardized motivational messages were read out to patients during an initial teaching session and through weekly telephone calls. Patients' compliance data were reviewed 2 and 6 weeks following CPAP initiation. We randomized 112 patients to groups that were matched for age, BMI, and OSA severity. The positively framed group (Pos) showed greater CPAP usage after 2 weeks (total use 53.7±31.4 hours) as compared to the negatively framed and the control group (35.6±27.4 and 40.8±33.5 hours, Pframed groups (Pos n=5; Neg n=8; Con n=11; Pframed messages can improve CPAP adherence in patients with OSA in the short-term; however, strategies for implementing its long-term use need to be developed.

  7. Prevention of Hypoxemia During Apnea Testing: A Comparison of Oxygen Insufflation And Continuous Positive Airway Pressure.

    Science.gov (United States)

    Kramer, Andreas H; Couillard, Philippe; Bader, Ryan; Dhillon, Peter; Kutsogiannis, Demetrios J; Doig, Christopher J

    2017-08-01

    Apnea testing is an essential step in the clinical diagnosis of brain death. Current international guidelines recommend placement of an oxygen (O 2 ) insufflation catheter into the endotracheal tube to prevent hypoxemia, but use of a continuous positive airway pressure (CPAP) valve may be more effective at limiting arterial partial pressure of O 2 (PO 2 ) reduction. We performed a multicenter study assessing consecutive apnea tests in 14 intensive care units (ICUs) in two cities utilizing differing protocols. In one city, O 2 catheters are placed and arterial blood gases (ABGs) performed at intervals determined by the attending physician. In the other city, a resuscitation bag with CPAP valve is attached to the endotracheal tube, and ABGs performed every 3-5 min. We assessed arterial PO 2 , partial pressure of carbon dioxide (PCO 2 ), pH, and blood pressure at the beginning and termination of each apnea test. Thirty-six apnea tests were performed using an O 2 catheter and 50 with a CPAP valve. One test per group was aborted because of physiological instability. There were no significant differences in the degree of PO 2 reduction (-59 vs. -32 mmHg, p = 0.72), rate of PCO 2 rise (3.2 vs. 3.9 mmHg per min, p = 0.22), or pH decline (-0.02 vs. -0.03 per min, p = 0.06). Performance of ABGs at regular intervals was associated with shorter test duration (10 vs. 7 min, p pressure decline (p = 0.006). Both methods of O 2 supplementation are associated with similar changes in arterial PO 2 and PCO 2 . Performance of ABGs at regular intervals shortens apnea test duration and may avoid excessive pH reduction and consequent hemodynamic effects.

  8. Influence of mouth opening on oropharyngeal humidification and temperature in a bench model of neonatal continuous positive airway pressure.

    Science.gov (United States)

    Fischer, Hendrik S; Ullrich, Tim L; Bührer, Christoph; Czernik, Christoph; Schmalisch, Gerd

    2017-02-01

    Clinical studies show that non-invasive respiratory support by continuous positive airway pressure (CPAP) affects gas conditioning in the upper airways, especially in the presence of mouth leaks. Using a new bench model of neonatal CPAP, we investigated the influence of mouth opening on oropharyngeal temperature and humidity. The model features the insertion of a heated humidifier between an active model lung and an oropharyngeal head model to simulate the recurrent expiration of heated, humidified air. During unsupported breathing, physiological temperature and humidity were attained inside the model oropharynx, and mouth opening had no significant effect on oropharyngeal temperature and humidity. During binasal CPAP, the impact of mouth opening was investigated using three different scenarios: no conditioning in the CPAP circuit, heating only, and heated humidification. Mouth opening had a strong negative impact on oropharyngeal humidification in all tested scenarios, but heated humidification in the CPAP circuit maintained clinically acceptable humidity levels regardless of closed or open mouths. The model can be used to test new equipment for use with CPAP, and to investigate the effects of other methods of non-invasive respiratory support on gas conditioning in the presence of leaks. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. Sleep Apnea Related Risk of Motor Vehicle Accidents is Reduced by Continuous Positive Airway Pressure: Swedish Traffic Accident Registry Data

    Science.gov (United States)

    Karimi, Mahssa; Hedner, Jan; Häbel, Henrike; Nerman, Olle; Grote, Ludger

    2015-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is associated with an increased risk of motor vehicle accidents (MVAs). The rate of MVAs in patients suspected of having OSA was determined and the effect of continuous positive airway pressure (CPAP) was investigated. Design: MVA rate in patients referred for OSA was compared to the rate in the general population using data from the Swedish Traffic Accident Registry (STRADA), stratified for age and calendar year. The risk factors for MVAs, using demographic and polygraphy data, and MVA rate before and after CPAP were evaluated in the patient group. Setting: Clinical sleep laboratory and population based control (n = 635,786). Patients: There were 1,478 patients, male sex 70.4%, mean age 53.6 (12.8) y. Interventions: CPAP. Measurements and Results: The number of accidents (n = 74) among patients was compared with the expected number (n = 30) from a control population (STRADA). An increased MVA risk ratio of 2.45 was found among patients compared with controls (P accident risk was most prominent in the elderly patients (65–80 y, seven versus two MVAs). In patients, driving distance (km/y), EDS (Epworth Sleepiness score ≥ 16), short habitual sleep time (≤ 5 h/night), and use of hypnotics were associated with increased MVA risk (odds ratios 1.2, 2.1, 2.7 and 2.1, all P ≤ 0.03). CPAP use ≥ 4 h/night was associated with a reduction of MVA incidence (7.6 to 2.5 accidents/1,000 drivers/y). Conclusions: The motor vehicle accident risk in this large cohort of unselected patients with obstructive sleep apnea suggests a need for accurate tools to identify individuals at risk. Sleep apnea severity (e.g., apnea-hypopnea index) failed to identify patients at risk. Citation: Karimi M, Hedner J, Häbel H, Nerman O, Grote L. Sleep apnea related risk of motor vehicle accidents is reduced by continuous positive airway pressure: Swedish traffic accident registry data. SLEEP 2015;38(3):341–349. PMID:25325460

  10. Effect of continuous positive airway pressure ventilation on prethrombotic state in patients with obstructive sleep apnea-hypopnea syndrome

    International Nuclear Information System (INIS)

    Guo Dianbao; Chen Xiangkun; Sheng Chunyong; Zhang Yingying

    2009-01-01

    To investigate the prethrombotic state (PTS) in patients with obstructive sleep apnea syndrome (OS-AS) and the effect of continuous positive airway pressure ventilation (CPAP) on their PTS, the blood samples of 49 patients with OSAS were taken before treatment and on day 30 after treatment respectively. The platelet aggregation ( PAG), P-selections, endothdlin-1 (ET-1) and plasma vom willebrand factor (vWF) in 49 patients and 42 health controls were detected by radioimmunoassay and enzyme-immunoassay. The results showed that the PAG, P-selections, ET-1 and vWF in patients with OSAS before treatment were significantly higher than those after treatment and in control group (P 0.05). The results indicate that there were PTS in most patients with OSAS before treatment. The activity of platelet could be corrected, and the function of endotheliocyte could be repaired after CPAP treatment. It had certain effect in lightening the clinical symptoms. (authors)

  11. Continuous Positive Airway Pressure Adherence In Patients with Obstructive Sleep Apnea & Symptomatic BPH.

    Science.gov (United States)

    Metta, Ramesh V V S; Zaka, Awais; Lee, Vincent C; Mador, M Jeffery

    2017-04-01

    Purpose To determine the short-term and long-term adherence rates with continuous positive airway pressure (CPAP) therapy in sleep apnea patients with benign prostatic hyperplasia (BPH) compared to matched controls. Methods A case-control retrospective analysis was performed in a veterans affairs hospital. All symptomatic patients with BPH (n = 107) ever started on CPAP therapy between 2006 and 2012 were compared with controls matched for severity of sleep apnea (AHI). Adherence measures were obtained at the third and twelfth month visits. The cases included symptomatic BPH patients on active medical therapy. Diuretic use among cases and controls, and severity of nocturia among the cases were also analyzed. Results The mean AHI among cases and controls was 35.6 ± 27.3 and 35.5 ± 31 (p = 0.96). The population was male and predominantly Caucasian. There was no statistically significant difference in percent days CPAP device use ≥4 h. between symptomatic BPH patients and controls at 3-month (51.6 ± 38 vs. 47.2 ± 36; p = 0.43) and 1-year (64 ± 40.5 vs. 64.7 ± 31.3; p = 0.90) visits. The use of diuretics in the cases and controls, and the severity of nocturia in the cases did not influence adherence with CPAP therapy. Conclusions BPH or diuretic use did not affect adherence with CPAP therapy in obstructive sleep apnea. Severity of nocturia did not have any influence on adherence among the cases. BPH, regardless of the severity of nocturia, and diuretic use does not influence CPAP adherence in patients with OSA.

  12. The Effect of Body Position on Pain Due to Nasal Continuous Positive Airway Pressure (CPAP in Premature Neonates: A Cross-Over Clinical Trial Study

    Directory of Open Access Journals (Sweden)

    Mahnaz Jabraeili

    2018-01-01

    Full Text Available Background The most common cause of admission to neonatal intensive care units (NICU is respiratory distress syndrome. One of the respiratory assistance methods is using nasal continuous positive airway pressure (CPAP. Regarding the importance of pain control which is one of the major priorities in neonatal nursing care, this study aimed to evaluate the effect of body position on pain due to nasal CPAP in premature neonates. Materials and Methods In this cross-over clinical trial, 50 premature neonates who were receiving nasal CPAP admitted to the NICU of Imam Reza Hospital, Kermanshah, Iran, were included. The neonates were randomly placed at three body positions (fetal, supine, and prone positions. Pain was measured by Astrid Lindgren Children’s Hospital Pain Scale Neonates (ALPS-Neo pain assessment scale. The collected data were analyzed using the SPSS software (Version 22.0. Results Significant difference existed regarding pain of nasal CPAP among body positions (p< 0.001. Mean (SD pain was 5.15 (0.822 in fetal position, 6.260 (0.747 in prone position and 7.326 (0.792 in supine position. Conclusion Body positioning in premature neonates under nasal CPAP in NICU can be effective as a non-pharmacologic method in alleviating pain due to nasal CPAP. Among the studied positions, the lowest pain score was seen in fetal position.

  13. Titration effectiveness of two autoadjustable continuous positive airway pressure devices driven by different algorithms in patients with obstructive sleep apnoea.

    Science.gov (United States)

    Damiani, Mario Francesco; Quaranta, Vitaliano Nicola; Tedeschi, Ersilia; Drigo, Riccardo; Ranieri, Teresa; Carratù, Pierluigi; Resta, Onofrio

    2013-08-01

    Nocturnal application of continuous positive airway pressure (CPAP) is the standard treatment for patients with obstructive sleep apnoea (OSA). Determination of the therapeutic pressure (CPAP titration) is usually performed by a technician in the sleep laboratory during attended polysomnography. One possible alternative to manual titration is automated titration. Indeed, during the last 15 years, devices have been developed that deliver autoadjustable CPAP (A-CPAP). The aim of the present study was to compare the titration effectiveness of two A-CPAP devices using different flow-based algorithms in patients with OSA. This is a randomized study; 79 subjects underwent two consecutive unattended home A-CPAP titration nights with two different devices (Autoset Resmed; Remstar Auto Respironics); during the third and the fourth night, patients underwent portable monitoring in the sleep laboratory during fixed CPAP at the A-CPAP recommended pressure. Bland Altman plots showed good agreement between the recommended median and maximal pressure levels obtained with the two devices. A significant improvement was observed in all the sleep parameters by both A-CPAP machines to a similar degree. It was observed that the two A-CPAP devices using different algorithms are equally effective in initial titration of CPAP. © 2013 The Authors. Respirology © 2013 Asian Pacific Society of Respirology.

  14. Self-Efficacy and Short-Term Adherence to Continuous Positive Airway Pressure Treatment in Children.

    Science.gov (United States)

    Xanthopoulos, Melissa S; Kim, Ji Young; Blechner, Michael; Chang, Ming-Yu; Menello, Mary Kate; Brown, Christina; Matthews, Edward; Weaver, Terri E; Shults, Justine; Marcus, Carole L

    2017-07-01

    Infants, children, and adolescents are increasingly being prescribed continuous positive airway pressure (CPAP) for treatment of obstructive sleep apnea syndrome (OSAS), yet adherence is often poor. The purpose of this study was to examine the relationship between caregiver and patient-reported health cognitions about CPAP prior to starting CPAP and CPAP adherence at 1 month. We hypothesized that greater caregiver-reported self-efficacy would be positively associated with CPAP adherence in children. We also evaluated patient-reported self-efficacy and caregiver- and patient-reported risk perception and outcome expectations as they related to adherence, as well as how demographic factors influenced these relationships. A pediatric modification of the Self-Efficacy Measure for Sleep Apnea Questionnaire was administered to children and adolescents with OSAS-prescribed CPAP and their caregivers during the clinical CPAP-initiation visit. The primary outcome variable for adherence was the average total minutes of CPAP usage across all days from the date that CPAP was initiated to 31 days later. Unadjusted ordinary least-square regression showed a significant association between caregiver-reported self-efficacy and adherence (p = .007), indicating that mean daily CPAP usage increased by 48.4 minutes when caregiver-reported self-efficacy increased by one point (95% confidence interval 13.4-83.4 minutes). No other caregiver- or patient-reported cognitive health variables were related to CPAP use. This study indicates that caregiver CPAP-specific self-efficacy is an important factor to consider when starting youth on CPAP therapy for OSAS. Employing strategies to improve caregiver self-efficacy, beginning at CPAP initiation, may promote CPAP adherence. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  15. Gel pillow designed specifically for obstructive sleep apnea treatment with continuous positive airway pressure.

    Science.gov (United States)

    Salvaggio, Adriana; Lo Bue, Anna; Isidoro, Serena Iacono; Romano, Salvatore; Marrone, Oreste; Insalaco, Giuseppe

    2016-01-01

    To determine whether the use of a gel pillow with side cutouts designed to accommodate a continuous positive airway pressure (CPAP) mask and reduce head temperature improves the efficacy of and adherence to auto-CPAP therapy. Twenty-three consecutive CPAP-naïve patients with obstructive sleep apnea were enrolled in the study. Patients were given an auto-CPAP machine with an appropriate CPAP mask and were instructed to use CPAP for 15 nights. They were instructed to sleep with their own pillow (the control pillow) from nights 1 to 5 and with either a foam pillow or a gel pillow, both of which had side cutouts, for 5 consecutive nights each, in random order. After night 15, auto-CPAP machine data were downloaded and patients rated their satisfaction with each pillow on a visual analog scale. Twenty-two patients completed the protocol. The pressures administered, residual apnea-hypopnea index, air leaks, and mean duration of CPAP use did not differ among the periods during which each pillow was used. Patients were significantly more satisfied with the gel pillow than with the control pillow and the foam pillow (p = 0.022 and p = 0.004, respectively), their level of satisfaction with the gel pillow correlating significantly with excessive daytime sleepiness (r2 = 0.19; p = 0.0443). Among obstructive sleep apnea patients treated with nasal CPAP, the use of a gel pillow with side cutouts appears to have no impact on treatment effectiveness. Nevertheless, such patients seem to prefer a gel pillow over other types of pillows. Determinar se o uso de um travesseiro de gel com recortes laterais para acomodar a máscara de continuous positive airway pressure (CPAP, pressão positiva contínua nas vias aéreas) e diminuir a temperatura em torno da cabeça melhora a eficácia do tratamento com auto-CPAP e a adesão dos pacientes ao tratamento. Foram incluídos no estudo 23 pacientes consecutivos com apneia obstrutiva do sono que nunca haviam recebido tratamento com CPAP. Os

  16. Auto-trilevel versus bilevel positive airway pressure ventilation for hypercapnic overlap syndrome patients.

    Science.gov (United States)

    Su, Mei; Huai, De; Cao, Juan; Ning, Ding; Xue, Rong; Xu, Meijie; Huang, Mao; Zhang, Xilong

    2018-03-01

    Although bilevel positive airway pressure (Bilevel PAP) therapy is usually used for overlap syndrome (OS), there is still a portion of OS patients in whom Bilevel PAP therapy could not simultaneously eliminate residual apnea events and hypercapnia. The current study was expected to explore whether auto-trilevel positive airway pressure (auto-trilevel PAP) therapy with auto-adjusting end expiratory positive airway pressure (EEPAP) can serve as a better alternative for these patients. From January of 2014 to June of 2016, 32 hypercapnic OS patients with stable chronic obstructive pulmonary diseases (COPD) and moderate-to-severe obstructive sleep apnea syndrome (OSAS) were recruited. Three variable modes of positive airway pressure (PAP) from the ventilator (Prisma25ST, Weinmann Inc., Germany) were applicated for 8 h per night. We performed the design of each mode at each night with an interval of two nights with no PAP treatment as a washout period among different modes. In Bilevel-1 mode (Bilevel-1), the expiratory positive airway pressure (EPAP) delivered from Bilevel PAP was always set as the lowest PAP for abolishment of snoring. For each patient, the inspiratory positive airway pressure (IPAP) was constantly set the same as the minimal pressure for keeping end-tidal CO 2 (ETCO 2 ) ≤45 mmHg for all three modes. However, the EPAP issued by Bilevel PAP in Bilevel-2 mode (Bilevel-2) was kept 3 cmH 2 O higher than that in Bilevel-1. In auto-trilevel mode (auto-trilevel) with auto-trilevel PAP, the initial part of EPAP was fixed at the same PAP as that in Bilevel-1 while the EEPAP was automatically regulated to rise at a range of ≤4 cmH 2 O based on nasal airflow wave changes. Comparisons were made for parameters before and during or following treatment as well as among different PAP therapy modes. The following parameters were compared such as nocturnal apnea hypopnea index (AHI), minimal SpO 2 (minSpO 2 ), arousal index, sleep structure and efficiency

  17. Continuous Positive Airway Pressure versus Mechanical Ventilation on the Fist Day of Life in Very Low-Birth-Weight Infants

    Science.gov (United States)

    Flannery, Dustin D.; O’Donnell, Elizabeth; Kornhauser, Mike; Dysart, Kevin; Greenspan, Jay; Aghai, Zubair H.

    2017-01-01

    Objective The objective of this study was to determine differences in the incidence of bronchopulmonary dysplasia (BPD) or death in very low-birth-weight (VLBW) infants managed successfully on continuous positive airway pressure (CPAP) versus mechanical ventilation on the first day of life (DOL). Study Design This is a retrospective analysis of the Alere neonatal database for infants born between January 2009 and December 2014, weighing ≤ 1,500 g. Baseline demographics, clinical characteristics, and outcomes were compared between the two groups. Multivariate regression analysis was performed to control the variables that differ in bivariate analysis. Results In this study, 4,629 infants (birth weight 1,034 ± 290 g, gestational age 28.1 ± 2.5 weeks) met the inclusion criteria. The successful use of early CPAP was associated with a significant reduction in BPD or death (p CPAP on the first DOL in VLBW infants is associated with a reduced risk of BPD or death. PMID:27057767

  18. Effects of 12 months continuous positive airway pressure on sympathetic activity related brainstem function and structure in obstructive sleep apnea.

    Directory of Open Access Journals (Sweden)

    Luke Anthony Henderson

    2016-03-01

    Full Text Available Muscle sympathetic nerve activity (MSNA is greatly elevated in patients with obstructive sleep apnoea (OSA during normoxic daytime wakefulness. Increased MSNA is a precursor to hypertension and elevated cardiovascular morbidity and mortality. However, the mechanisms underlying the high MSNA in OSA are not well understood. In this study we used concurrent microneurography and magnetic resonance imaging to explore MSNA-related brainstem activity changes and anatomical changes in 15 control and 15 subjects with OSA prior to and following 6 and 12 months of continuous positive airway pressure (CPAP treatment. We found that 6 and 12 months of CPAP treatment significantly reduced the elevated resting MSNA in individuals with OSA. Furthermore, this MSNA reduction was associated with restoration of MSNA-related activity and structural changes in the medullary raphe, rostral ventrolateral medulla, dorsolateral pons and ventral midbrain. This restoration occurred after 6 months of CPAP treatment and was maintained following 12 months CPAP. These findings show that continual CPAP treatment is an effective long-term treatment for elevated MNSA likely due to its effects on restoring brainstem structure and function.

  19. Continuous positive airway pressure with helmet versus mask in infants with bronchiolitis: an RCT.

    Science.gov (United States)

    Chidini, Giovanna; Piastra, Marco; Marchesi, Tiziana; De Luca, Daniele; Napolitano, Luisa; Salvo, Ida; Wolfler, Andrea; Pelosi, Paolo; Damasco, Mirco; Conti, Giorgio; Calderini, Edoardo

    2015-04-01

    Noninvasive continuous positive airway pressure (CPAP) is usually applied with a nasal or facial mask to treat mild acute respiratory failure (ARF) in infants. A pediatric helmet has now been introduced in clinical practice to deliver CPAP. This study compared treatment failure rates during CPAP delivered by helmet or facial mask in infants with respiratory syncytial virus-induced ARF. In this multicenter randomized controlled trial, 30 infants with respiratory syncytial virus-induced ARF were randomized to receive CPAP by helmet (n = 17) or facial mask (n = 13). The primary endpoint was treatment failure rate (defined as due to intolerance or need for intubation). Secondary outcomes were CPAP application time, number of patients requiring sedation, and complications with each interface. Compared with the facial mask, CPAP by helmet had a lower treatment failure rate due to intolerance (3/17 [17%] vs 7/13 [54%], P = .009), and fewer infants required sedation (6/17 [35%] vs 13/13 [100%], P = .023); the intubation rates were similar. In successfully treated patients, CPAP resulted in better gas exchange and breathing pattern with both interfaces. No major complications due to the interfaces occurred, but CPAP by mask had higher rates of cutaneous sores and leaks. These findings confirm that CPAP delivered by helmet is better tolerated than CPAP delivered by facial mask and requires less sedation. In addition, it is safe to use and free from adverse events, even in a prolonged clinical setting. Copyright © 2015 by the American Academy of Pediatrics.

  20. Short-term effects of positive expiratory airway pressure in patients being weaned from mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Marcelo de Mello Rieder

    2009-05-01

    Full Text Available OBJECTIVE: To investigate the feasibility and the cardiorespiratory effects of using positive expiratory airway pressure, a physiotherapeutic tool, in comparison with a T-tube, to wean patients from mechanical ventilation. METHODS/DESIGN: A prospective, randomized, cross-over study. SETTING: Two intensive care units. PATIENTS AND INTERVENTIONS: We evaluated forty patients who met weaning criteria and had been mechanically-ventilated for more than 48 hours, mean age 59 years, including 23 males. All patients were submitted to the T-tube and Expiratory Positive Airway Pressure devices, at 7 cm H2O, during a 30-minute period. Cardiorespiratory variables including work of breathing, respiratory rate (rr, peripheral oxygen saturation (SpO2, heart rate (hr, systolic, diastolic and mean arterial pressures (SAP, DAP, MAP were measured in the first and thirtieth minutes. The condition was analyzed as an entire sample set (n=40 and was also divided into subconditions: chronic obstructive pulmonary disease (n=14 and non-chronic obstructive pulmonary disease (non- chronic obstructive pulmonary disease (n=26 categories. Comparisons were made using a t-test and Analysis of Variance. The level of significance was p < 0.05. RESULTS: Our data showed an increase in work of breathing in the first and thirtieth minutes in the EPAP condition (0.86+ 0.43 and 1.02+1.3 as compared with the T-tube condition (0.25+0.26 and 0.26+0.35 (p<0.05, verified by the flow-sensor monitor (values in J/L. No statistical differences were observed when comparing the Expiratory Positive Airway Pressure and T-tube conditions with regard to cardiorespiratory measurements. The same result was observed for both chronic obstructive pulmonary disease and non- chronic obstructive pulmonary disease subconditions. CONCLUSIONS: Our study demonstrated that, in weaning patients from mechanical ventilation, the use of a fixed level of Expiratory Positive Airway Pressure caused an increase in work of

  1. Comparison of sprinting vs non-sprinting to wean nasal continuous positive airway pressure off in very preterm infants.

    Science.gov (United States)

    Eze, N; Murphy, D; Dhar, V; Rehan, V K

    2018-02-01

    Though nasal continuous positive airway pressure (NCPAP) is commonly used for non-invasive neonatal respiratory support, the optimal method of weaning NCPAP is not established. In this prospective, two-center randomized control trial we hypothesize that gradually increasing spontaneous breathing time off NCPAP increases successful weaning from NCPAP in infants born 0.05). It took 1.3 (1 to 1.75) (median (IQR)) attempts and 7 (7 to 7) days to wean NCPAP off in the sprinting group vs 1.3 (1 to 1.75) attempts and 7 (7 to 10) days in the non-sprinting group (P>0.05). Additionally, no differences in the secondary outcomes of bronchopulmonary dysplasia, severe retinopathy of prematurity (⩾stage 3), periventricular leukomalacia and length of stay were noted between the two groups. Weaning NCPAP via sprinting or non-sprinting protocol is comparable, not only for successful weaning but also for the occurrence of common neonatal morbidities that impact the long-term outcome in premature infants (ClinicalTrials.gov number, NCT02819050).

  2. Continuous positive airway pressure reduces blood pressure in patients with obstructive sleep apnea; a systematic review and meta-analysis with 1000 patients.

    Science.gov (United States)

    Schein, Andressa S O; Kerkhoff, Alessandra C; Coronel, Christian C; Plentz, Rodrigo D M; Sbruzzi, Graciele

    2014-09-01

    Obstructive sleep apnea (OSA) may lead to the development of hypertension and therapy with continuous positive airway pressure (CPAP) can promote reduction in blood pressure. The objective of this study is to review systematically the effects of CPAP on blood pressure in patients with OSA. The search was conducted in the following databases, from their beginning until February 2013: MEDLINE, Embase, Cochrane CENTRAL, Lilacs and PEDro. In addition, a manual search was performed on references of published studies. Randomized clinical trials (RCTs) that used CPAP compared with placebo CPAP or subtherapeutic CPAP for treatment of patients with OSA and that evaluated office SBP and DBP and 24-h ambulatory blood pressure were selected. Sixteen RCTs were included among 3409 publications, totaling 1166 patients. The use of CPAP resulted in reductions in office SBP [-3.20  mmHg; 95% confidence interval (CI) -4.67 to -1.72] and DBP (-2.87  mmHg; 95% CI -5.18 to -0.55); in night-time SBP (-4.92  mmHg; 95% CI -8.70 to -1.14); in mean 24-h blood pressure (-3.56  mmHg; 95% CI -6.79 to -0.33), mean night-time blood pressure (-2.56  mmHg; 95% CI -4.43 to -0.68) and 24-h DBP (-3.46  mmHg; 95% CI -6.75 to -0.17). However, no significant change was observed in daytime SBP (-0.74  mmHg; 95% CI -3.90 to 2.41) and daytime DBP (-1.86  mmHg; 95% CI -4.55 to 0.83). Treatment with CPAP promoted significantly but small reductions in blood pressure in individuals with OSA. Further studies should be performed to evaluate the effects of long-term CPAP and the impact on cardiovascular risk.

  3. Noninvasive Positive Pressure Ventilatory Support Begins During Sleep.

    Science.gov (United States)

    Bach, John R

    2017-12-01

    The goal of sleep doctors has been to titrate away apneas and hypopneas using noninvasive ventilation, a term that has become synonymous with continuous positive airway pressure and bilevel positive airway pressure at the lowest effective bilevel settings. It is now time to appreciate noninvasive ventilatory support as an alternative to invasive mechanical ventilation. This article discusses mechanisms of action, two paradigms, and ancillary techniques for noninvasive ventilatory support. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Nasal continuous positive airway pressure (n-CPAP) does not change cardiac output in preterm infants.

    Science.gov (United States)

    Moritz, Barbara; Fritz, Michael; Mann, Christian; Simma, Burkhard

    2008-02-01

    Our objective was to study how invasive mechanical ventilation impairs cardiac output (CO) in children and adults. Although the application of continuous positive airway pressure (CPAP) is widely practiced in neonatal intensive care, its hemodynamic consequences have not yet been investigated. A prospective study to assess the hemodynamic effects was conducted in 21 preterm infants CPAP (n-CPAP). Gestational age was 28.0 +/- 1.9 weeks (mean +/- standard deviation); birthweight, 1000 +/- 238 g; age at study entry, 200 +/- 155 hours; total maintenance fluid, 154 +/- 42 mL/kg/day; and n-CPAP level, 4.4 +/- 0.9 cm H(2)O. None of the infants received inotropic support, and n-CPAP did not cause any significant difference in the parameters measured: stroke volume, 3.1 +/- 1.0 mL (with n-CPAP) versus 3.1 +/- 1.0 mL (without n-CPAP); cardiac output, 487 +/- 156 mL/minute versus 500 +/- 176 mL/minute; left ventricular diastolic diameter, 1.22 +/- 0.15 cm versus 1.24 +/- 0.14 cm; fractional shortening, 0.30 +/- 0.05% versus 0.29 +/- 0.04%; and aortic velocity-time integral, 8.64 +/- 1.80 cm versus 8.70 +/- 1.65 cm. The n-CPAP level did not influence CO; n-CPAP (up to 7 cm H (2)O) has no echocardiographically detectable hemodynamic effect in preterm infants. Our data imply there is no need to withhold n-CPAP support to prevent circulatory compromise in these infants.

  5. Oronasal mask may compromise the efficacy of continuous positive airway pressure on OSA treatment: is there evidence for avoiding the oronasal route?

    Science.gov (United States)

    Andrade, Rafaela Garcia Santos; Madeiro, Fernanda; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2016-11-01

    Continuous positive airway pressure (CPAP) delivered by nasal mask is the gold standard treatment for obstructive sleep apnea (OSA). However, oral and oronasal masks are also available. We considered experimental evidence and reviewed clinical trials that evaluated the impact of oral and oronasal mask on OSA treatment. One recent study in 18 OSA patients that slept with a customized oronasal mask with two sealed compartments showed that the change of CPAP flow from nasal to oronasal and oral caused upper airway obstruction because of posterior displacement of the tongue demonstrated by nasoendoscopy. Oral masks use a mouthpiece that may stabilize the jaw and the tongue and have shown to be effective. However, oral masks are not widely used in clinical practice. Four out of five observational studies and all five reviewed randomized studies showed a worse performance of oronasal when compared with nasal masks. Oronasal masks were associated with higher residual apnea-hypopnea index, lower adherence, more leaks, and less satisfaction than nasal mask in the majority of the studies. Nasal CPAP must be the first choice to treat OSA. Patients on oronasal mask should be carefully followed. VIDEO ABSTRACT.

  6. Effectiveness of prehospital continuous positive airway pressure in the management of acute pulmonary edema.

    Science.gov (United States)

    Hubble, Michael W; Richards, Michael E; Jarvis, Roger; Millikan, Tori; Young, Dwayne

    2006-01-01

    To compare the effectiveness of continuous positive airway pressure (CPAP) with standard pharmacologic treatment in the management of prehospital acute pulmonary edema. Using a nonrandomized control group design, all consecutive patients presenting to two participating emergency medical services (EMS) systems with a field impression of acute pulmonary edema between July 1, 2004, and June 30, 2005, were included in the study. The control EMS system patients received standard treatment with oxygen, nitrates, furosemide, morphine, and, if indicated, endotracheal intubation. The intervention EMS system patients received CPAP via face mask at 10 cm H2O in addition to standard therapy. Ninety-five patients received standard therapy, and 120 patients received CPAP and standard therapy. Intubation was required in 8.9% of CPAP-treated patients compared with 25.3% in the control group (p = 0.003), and mortality was lower in the CPAP group than in the control group (5.4% vs. 23.2%; p = 0.000). When compared with the control group, the CPAP group had more improvement in respiratory rate (-4.55 vs. -1.81; p = 0.001), pulse rate (-4.77 vs. 0.82; p = 0.013), and dyspnea score (-2.11 vs. -1.36; p = 0.008). Using logistic regression to control for potential confounders, patients receiving standard treatment were more likely to be intubated (odds ratio, 4.04; 95% confidence interval, 1.64 to 9.95) and more likely to die (odds ratio, 7.48; 95% confidence interval, 1.96 to 28.54) than those receiving standard therapy and CPAP. The prehospital use of CPAP is feasible, may avert the need for endotracheal intubation, and may reduce short-term mortality.

  7. Improvement in Physical Activity in Persons With Obstructive Sleep Apnea Treated With Continuous Positive Airway Pressure.

    Science.gov (United States)

    Jean, Raymonde E; Duttuluri, Manideep; Gibson, Charlisa D; Mir, Sadaf; Fuhrmann, Katherine; Eden, Edward; Supariwala, Azhar

    2017-03-01

    Exercise improves sleep quality, yet people with untreated obstructive sleep apnea (OSA) may engage in less physical activity (PA) due to fatigue and daytime sleepiness. We examined changes in PA and sleep quality before and after treatment with continuous positive airway pressure (CPAP) in OSA patients. In this prospective longitudinal study, persons with a primary diagnosis of OSA were enrolled at a community-based hospital in New York City. At 3 time intervals pre- and post-CPAP (3-8 months), we measured sleep quality using validated questionnaires, perceived PA using the International Physical Activity Questionnaire (IPAQ), and actual PA using pedometer steps per day. We sought to investigate how CPAP use and changes in sleep quality impacted the number of steps taken, as recorded in pedometer steps. In total, 62 patients were enrolled in the study from March 2012 to July 2014. In all, patients averaged 53 years of age, and 26 patients (42%) were female. Among all participants, 86% of persons had moderate to severe sleep apnea (AHI ≥15). Approximately 73% of participants were compliant with CPAP use. Poor sleep quality correlated with lower actual PA (P = .004) at baseline. At 3 and 7 months, there was significant improvement in sleep quality (Δ -2.63 ± 3.4 and Δ -3.5 ± 3.8; P improvement in sleep quality and actual PA.

  8. Role of spousal involvement in continuous positive airway pressure (CPAP adherence in patients with obstructive sleep apnea (OSA

    Directory of Open Access Journals (Sweden)

    Batool-Anwar S

    2017-05-01

    Full Text Available Introduction: Little is known about the impact of spousal involvement on continuous positive airway pressure (CPAP adherence. The aim of this study was to determine whether spouse involvement affects adherence with CPAP therapy, and how this association varies with gender. Methods: 194 subjects recruited from Apnea Positive Pressure Long Term Efficacy Study (APPLES completed the Dyadic Adjustment Scale (DAS. The majority of participants were Caucasian (83%, and males (73%, with mean age of 56 years, mean BMI of 31 kg/m2. & 62% had severe OSA. The DAS is a validated 32-item self-report instrument measuring dyadic consensus, satisfaction, cohesion, and affectional expression. A high score in the DAS is indicative of a person’s adjustment to the marriage. Additionally, questions related to spouse involvement with general health and CPAP use were asked. CPAP use was downloaded from the device and self-report, and compliance was defined as usage > 4 h per night. Results: There were no significant differences in overall marital quality between the compliant and noncompliant subjects. However, level of spousal involvement was associated with increased CPAP adherence at 6 months (p=0.01. After stratifying for gender these results were significant only among males (p=0.03. Three years after completing APPLES, level of spousal involvement was not associated with CPAP compliance even after gender stratification. Conclusion: Spousal involvement is important in determining CPAP compliance in males in the 1st 6 months after initiation of therapy but is not predictive of longer-term adherence. Involvement of the spouse should be considered an integral part of CPAP initiation procedures.

  9. Continuous Positive Airway Pressure (CPAP)

    Science.gov (United States)

    ... Sleep Apnea? Lifestyle change including weight loss and exercise can help to improve sleep apnea and its related health problems. Sleep positioning and oral appliances have also been found to be effective. In cases when non-invasive treatments fail, a ...

  10. Quality Improvement of Nasal Continuous Positive Airway Pressure Therapy in Neonatal Intensive Care Unit.

    Science.gov (United States)

    Chen, Chien-Yi; Chou, An-Kuo; Chen, Yu-Lien; Chou, Hung-Chieh; Tsao, Po-Nien; Hsieh, Wu-Shiun

    2017-06-01

    Nasal continuous positive airway pressure (NCPAP) therapy is widely used in neonates, but the clinical practice varies. However, nursing practice differs among individuals, and an inappropriate application method may delay the respiratory therapy, influence the beneficial effect of NCPAP, and increase complications. We introduced a quality improvement project to expedite the application of NCPAP therapy and decrease the incidence of nasal trauma. A new strategy of mobile NCPAP cart with prepacked fixation kits and a written protocol was implemented from April 2006. All medical staff answered a questionnaire to assess their basic knowledge before and after intensive training. The records of the patients who were treated with NCPAP from October 2005 to November 2006 were reviewed. Fifty-nine medical staff were involved in the project, and their mean score for the questionnaire improved from 69.2 points to 98.3 points after training. From October 2005 to November 2006, 113 infants were recruited in total and 82 of them were admitted after the protocol was implemented. The NCPAP cart dramatically shortened the preparation time (from 520 seconds to 72 seconds) and the application time (from 468 seconds to 200 seconds). The use of the nursing protocol significantly decreased the incidence of nasal trauma in the study population (45.2% vs. 19.6%, p = 0.006), but not in infants with a birth weight of < 1000 g. Risk factors for nasal skin trauma included lower gestational age and birth weight, longer duration of NCPAP use, and lack of standardized nursing care. The mobile NCPAP cart with prepacked fixation kits is a practical way of expediting the initiation of NCPAP therapy. The written nursing protocol decreased the incidence of nasal trauma in infants, except for those with an extremely low birth weight. Copyright © 2016. Published by Elsevier B.V.

  11. Continuous Positive Airway Pressure: Is it a route for infection in those with Obstructive Sleep Apnoea?

    Directory of Open Access Journals (Sweden)

    Liam Mercieca

    Full Text Available Introduction: Continuous positive airway pressure (CPAP is the standard treatment for obstructive sleep apnoea (OSA, with limited data about the prevalence of respiratory infections and microbial colonization in these patients. Objectives: The aim of this study was to determine if CPAP use is associated with respiratory infections and to identify the organisms that colonize or infect these patients. Method: A retrospective, case-controlled study in patients diagnosed with OSA was carried out. 137 patients were recruited and interviewed using a questionnaire. A nasal swab was taken from each patient. Patients using CPAP machines had swabs taken from masks and humidifiers. Results: 66 (48.2% patients received CPAP treatment with 60.6% of them having a heated humidifier. 78.8% were male, with the majority using a full face mask (63.6%. No significant difference was seen in the prevalence of rhinosinusitis, lower respiratory tract infections and hospital admissions for pneumonia between CPAP and non-CPAP treated patients. The presence of a humidifier did not influence the prevalence of infections. Commensal flora was predominantly cultured from nasal swabs from both patient groups. Coagulase Negative Staphylococci and Diphtheroids were the main organisms cultured from masks and humidifiers respectively. Conclusions: This study shows that the use of CPAP, choice of mask and humidifier have no significant impact on the prevalence of infections and micro-organisms isolated. This is very reassuring to the physician prescribing CPAP therapy and users.

  12. Nasal pillows as an alternative interface in patients with obstructive sleep apnoea syndrome initiating continuous positive airway pressure therapy.

    LENUS (Irish Health Repository)

    Ryan, Silke

    2012-02-01

    Side-effects directly due to the nasal mask are common in patients with obstructive sleep apnoea syndrome (OSAS) commencing continuous positive airway pressure (CPAP). Recently, nasal pillows have been designed to overcome these issues. Limited evidence exists of the benefits and effectiveness of these devices. Twenty-one patients (19 male, 49+\\/-10years) with the established diagnosis of OSAS [apnoea\\/hypopnoea index (AHI): 52+\\/-22] and who had a successful CPAP titration were commenced on CPAP therapy (10+\\/-2cmH2O), and randomized to 4weeks of a nasal pillow (P) and a standard nasal mask (M) in a crossover design. Outcome measures were objective compliance, AHI, quality of life, Epworth Sleepiness Score (ESS) and CPAP side-effects. There was no difference in compliance (M versus P: 5.1+\\/-1.9h versus 5.0+\\/-1.7h; P=0.701) and AHI (2.6+\\/-2.7 versus 3.0+\\/-2.9; P=0.509). Quality of life and ESS improved with CPAP, but there was no difference in the extent of improvement between both devices. Usage of nasal pillows resulted in less reported pressure on the face and more subjects found the nasal pillow the more comfortable device. However, there was no clear overall preference for either device at the end of the study (mask=57%, pillow=43%; P=0.513). The applied CPAP pressure did not correlate with compliance, AHI and ESS. Furthermore, no differences in outcome parameters were noted comparing groups with CPAP pressure <10 and >\\/=10cm H(2) O. Nasal pillows are equally effective in CPAP therapy, but do not generally lead to improved compliance.

  13. Estimates of cost-effectiveness of prehospital continuous positive airway pressure in the management of acute pulmonary edema.

    Science.gov (United States)

    Hubble, Michael W; Richards, Michael E; Wilfong, Denise A

    2008-01-01

    To estimate the cost-effectiveness of continuous positive airway pressure (CPAP) in managing prehospital acute pulmonary edema in an urban EMS system. Using estimates from published reports on prehospital and emergency department CPAP, a cost-effectiveness model of implementing CPAP in a typical urban EMS system was derived from the societal perspective as well as the perspective of the implementing EMS system. To assess the robustness of the model, a series of univariate and multivariate sensitivity analyses was performed on the input variables. The cost of consumables, equipment, and training yielded a total cost of $89 per CPAP application. The theoretical system would be expected to use CPAP 4 times per 1000 EMS patients and is expected to save 0.75 additional lives per 1000 EMS patients at a cost of $490 per life saved. CPAP is also expected to result in approximately one less intubation per 6 CPAP applications and reduce hospitalization costs by $4075 per year for each CPAP application. Through sensitivity analyses the model was verified to be robust across a wide range of input variable assumptions. Previous studies have demonstrated the clinical effectiveness of CPAP in the management of acute pulmonary edema. Through a theoretical analysis which modeled the costs and clinical benefits of implementing CPAP in an urban EMS system, prehospital CPAP appears to be a cost-effective treatment.

  14. Influence of continuous positive airway pressure on outcomes of rehabilitation in stroke patients with obstructive sleep apnea.

    Science.gov (United States)

    Ryan, Clodagh M; Bayley, Mark; Green, Robin; Murray, Brian J; Bradley, T Douglas

    2011-04-01

    In stroke patients, obstructive sleep apnea (OSA) is associated with poorer functional outcomes than in those without OSA. We hypothesized that treatment of OSA by continuous positive airway pressure (CPAP) in stroke patients would enhance motor, functional, and neurocognitive recovery. This was a randomized, open label, parallel group trial with blind assessment of outcomes performed in stroke patients with OSA in a stroke rehabilitation unit. Patients were assigned to standard rehabilitation alone (control group) or to CPAP (CPAP group). The primary outcomes were the Canadian Neurological scale, the 6-minute walk test distance, sustained attention response test, and the digit or spatial span-backward. Secondary outcomes included Epworth Sleepiness scale, Stanford Sleepiness scale, Functional Independence measure, Chedoke McMaster Stroke assessment, neurocognitive function, and Beck depression inventory. Tests were performed at baseline and 1 month later. Patients assigned to CPAP (n=22) experienced no adverse events. Regarding primary outcomes, compared to the control group (n=22), the CPAP group experienced improvement in stroke-related impairment (Canadian Neurological scale score, PStroke assessment of upper and lower limb motor recovery test of the leg (P=0.001), and the affective component of depression (P=0.006), but not neurocognitive function. Treatment of OSA by CPAP in stroke patients undergoing rehabilitation improved functional and motor, but not neurocognitive outcomes. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00221065.

  15. Continuous positive airway pressure improves gait control in severe obstructive sleep apnoea: A prospective study.

    Directory of Open Access Journals (Sweden)

    Sébastien Baillieul

    Full Text Available Severe obstructive sleep apnoea (OSA can lead to neurocognitive alterations, including gait impairments. The beneficial effects of continuous positive airway pressure (CPAP on improving excessive daytime sleepiness and daily functioning have been documented. However, a demonstration of CPAP treatment efficacy on gait control is still lacking. This study aims to test the hypothesis that CPAP improves gait control in severe OSA patients.In this prospective controlled study, twelve severe OSA patients (age = 57.2±8.9 years, body mass index = 27.4±3.1 kg·m-2, apnoea-hypopnoea index = 46.3±11.7 events·h-1 and 10 healthy matched subjects were included. Overground gait parameters were recorded at spontaneous speed and stride time variability, a clinical marker of gait control, was calculated. To assess the role of executive functions in gait and postural control, a dual-task paradigm was applied using a Stroop test as secondary cognitive task. All assessments were performed before and after 8 weeks of CPAP treatment.Before CPAP treatment, OSA patients had significantly larger stride time variability (3.1±1.1% vs 2.1±0.5% and lower cognitive performances under dual task compared to controls. After CPAP treatment, stride time variability was significantly improved and no longer different compared to controls. Cognitive performance under dual task also improved after CPAP treatment.Eight weeks of CPAP treatment improves gait control of severe OSA patients, suggesting morphological and functional cerebral improvements. Our data provide a rationale for further mechanistic studies and the use of gait as a biomarker of OSA brain consequences.

  16. Oxidative stress mediated arterial dysfunction in patients with obstructive sleep apnoea and the effect of continuous positive airway pressure treatment

    Directory of Open Access Journals (Sweden)

    Del Ben Maria

    2012-07-01

    Full Text Available Abstract Background Several studies suggest an increase of oxidative stress and a reduction of endothelial function in obstructive sleep apnoea syndrome (OSAS. We assessed the association between OSAS, endothelial dysfunction and oxidative stress. Further aim was to evaluate the effect of nasal continuous positive airway pressure (nCPAP on oxidative stress and arterial dysfunction. Methods We studied 138 consecutive patients with heavy snoring and possible OSAS. Patients underwent unattended overnight home polysomnography. Ten patients with severe OSAS were revaluated after 6 months of nCPAP therapy. To assess oxidative stress in vivo, we measured urinary 8-iso-PGF2α and serum levels of soluble NOX2-derived peptide (sNOX2-dp. Serum levels of nitrite/nitrate (NOx were also determined. Flow-mediated brachial artery dilation (FMD was measured to asses endothelial function. Results Patients with severe OSAS had higher urinary 8-iso-PGF2α (p Conclusions The results of our study indicate that patients with OSAS and cardiometabolic comorbidities have increased oxidative stress and arterial dysfunction that are partially reversed by nCPAP treatment.

  17. [Influence of nasal continuous positive airway pressure on response to exercise in patients with obstructive sleep apnea syndrome].

    Science.gov (United States)

    Przybyłowski, Tadeusz; Bielicki, Piotr; Kumor, Marta; Hildebrand, Katarzyna; Maskey-Warzechowska, Marta; Wiwała, Joanna; Kościuch, Justyna; Korczyński, Piotr; Chazan, Ryszarda

    2006-01-01

    Obstructive sleep apnea syndrome (OSAS) patients are at risk of cardiovascular complications. The aim of this study was to assess the effect of treatment with continuous positive airway pressure (CPAP) on the response to symptom limited exercise test. twenty nine OSAS patients (1 F, 28 M), mean age 50.7+/-9.7 yrs with body mass index of 32.6+/-4.5 kg/m2 participated in the study. OSAS was diagnosed by overnight polysomnography. Incremental cardiopulmonary exercise test (CPET) on a treadmill was performed twice: before and after 2-3 weeks of regular treatment with CPAP. mean apnea + hypopnea index (AHI) before therapy was 57.6+/-12 h(-1). CPAP treatment did not change peak oxygen consumption (VO2max) (38.3+/-9.0 vs. 38.9+/-6.9 mlO2/kg/min, p=ns) or peak heart rate (153.4+/-21 min- vs. 155.5+/-22 min(-1), p=ns). There were no significant changes in ventilation or gas exchange variables. However, a decrease in peak systolic blood pressure from 194.5+/-24 mmHg to 186.7+/-27.9 mmHg (prate (at 1st minute and minutes 3 - 6) and mean arterial pressure (MAP) (minutes 4-7) with CPAP treatment was observed. Significant correlations between VO2max and AHI (r=-0,38, p<0,05); MAP at peak exercise and: AHI, mean oxygen saturation (SaO2) during sleep, minutes of sleep with SaO2<90% (T90); MAP at recovery (minutes 3-8) and T90 before CPAP treatment were also noted. OSAS patients are not limited on exercise. Treatment with nasal CPAP attenuates circulatory response to incremental exercise on a treadmill.

  18. Corneal Neovascularization with Associated Lipid Keratopathy in a Patient with Obstructive Sleep Apnea-Hypopnea Syndrome Using a Continuous Positive Airway Pressure Machine

    Directory of Open Access Journals (Sweden)

    Konstantinos Oikonomakis

    2017-08-01

    Full Text Available Objective: To report a case of corneal neovascularization with secondary lipid keratopathy in a patient treated with continuous positive airway pressure (CPAP for obstructive sleep apnea-hypopnea syndrome (OSAHS. Case Report: A 49-year-old male had been diagnosed with obstructive sleep apnea syndrome 10 years ago and has been treated with the application of a CPAP machine during night sleep ever since. For the past year, the patient had been complaining for ocular irritation and excessive tearing of the left eye on awakening. Slit-lamp biomicroscopy revealed the presence of neovascularization and lipid exudation in the inferior third of the cornea of the left eye. Ocular patching during night sleep resulted in recession of the reported symptoms and shrinkage of the neovascularization, while the area of lipid exudation ceased to enlarge. Conclusion: To the best of our knowledge, this is the first report of corneal neovascularization in a patient using a CPAP machine for OSAHS.

  19. Corneal Neovascularization with Associated Lipid Keratopathy in a Patient with Obstructive Sleep Apnea-Hypopnea Syndrome Using a Continuous Positive Airway Pressure Machine.

    Science.gov (United States)

    Oikonomakis, Konstantinos; Petrelli, Myrsini; Andreanos, Konstantinos; Mouchtouris, Andreas; Petrou, Petros; Georgalas, Ilias; Papaconstantinou, Dimitrios; Kymionis, George

    2017-01-01

    To report a case of corneal neovascularization with secondary lipid keratopathy in a patient treated with continuous positive airway pressure (CPAP) for obstructive sleep apnea-hypopnea syndrome (OSAHS). A 49-year-old male had been diagnosed with obstructive sleep apnea syndrome 10 years ago and has been treated with the application of a CPAP machine during night sleep ever since. For the past year, the patient had been complaining for ocular irritation and excessive tearing of the left eye on awakening. Slit-lamp biomicroscopy revealed the presence of neovascularization and lipid exudation in the inferior third of the cornea of the left eye. Ocular patching during night sleep resulted in recession of the reported symptoms and shrinkage of the neovascularization, while the area of lipid exudation ceased to enlarge. To the best of our knowledge, this is the first report of corneal neovascularization in a patient using a CPAP machine for OSAHS.

  20. Cost-effectiveness of Out-of-Hospital Continuous Positive Airway Pressure for Acute Respiratory Failure.

    Science.gov (United States)

    Thokala, Praveen; Goodacre, Steve; Ward, Matt; Penn-Ashman, Jerry; Perkins, Gavin D

    2015-05-01

    We determine the cost-effectiveness of out-of-hospital continuous positive airway pressure (CPAP) compared with standard care for adults presenting to emergency medical services with acute respiratory failure. We developed an economic model using a United Kingdom health care system perspective to compare the costs and health outcomes of out-of-hospital CPAP to standard care (inhospital noninvasive ventilation) when applied to a hypothetical cohort of patients with acute respiratory failure. The model assigned each patient a probability of intubation or death, depending on the patient's characteristics and whether he or she had out-of-hospital CPAP or standard care. The patients who survived accrued lifetime quality-adjusted life-years (QALYs) and health care costs according to their age and sex. Costs were accrued through intervention and hospital treatment costs, which depended on patient outcomes. All results were converted into US dollars, using the Organisation for Economic Co-operation and Development purchasing power parities rates. Out-of-hospital CPAP was more effective than standard care but was also more expensive, with an incremental cost-effectiveness ratio of £20,514 per QALY ($29,720/QALY) and a 49.5% probability of being cost-effective at the £20,000 per QALY ($29,000/QALY) threshold. The probability of out-of-hospital CPAP's being cost-effective at the £20,000 per QALY ($29,000/QALY) threshold depended on the incidence of eligible patients and varied from 35.4% when a low estimate of incidence was used to 93.8% with a high estimate. Variation in the incidence of eligible patients also had a marked influence on the expected value of sample information for a future randomized trial. The cost-effectiveness of out-of-hospital CPAP is uncertain. The incidence of patients eligible for out-of-hospital CPAP appears to be the key determinant of cost-effectiveness. Copyright © 2015 American College of Emergency Physicians. Published by Elsevier Inc. All

  1. Effect of Continuous Positive Airway Pressure on Adiponectin in Patients with Obstructive Sleep Apnea: A Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Li-Da Chen

    Full Text Available Obstructive sleep apnea (OSA has been suggested to be associated with low levels of adiponectin. Continuous positive airway pressure (CPAP is the gold standard treatment for OSA; however, previous studies assessing the effect of CPAP on adiponectin in patients with OSA yielded conflicting results. The present meta-analysis was performed to determine whether CPAP therapy could increase adiponectin levels.Two reviewers independently searched PubMed, Cochrane library, Embase and Web of Science before February 2015. Information on characteristics of subjects, study design and pre- and post-CPAP treatment of serum adiponectin was extracted for analysis. Standardized mean difference (SMD was used to analyze the summary estimates for CPAP therapy.Eleven studies involving 240 patients were included in this meta-analysis, including ten observational studies and one randomized controlled study. The meta-analysis showed that there was no change of adiponectin levels before and after CPAP treatment in OSA patients (SMD = 0.059, 95% confidence interval (CI = -0.250 to 0.368, z = 0.37, p = 0.710. Subgroup analyses indicated that the results were not affected by age, baseline body mass index, severity of OSA, CPAP therapy duration, sample size and racial differences.This meta-analysis suggested that CPAP therapy has no impact on adiponectin in OSA patients, without significant changes in body weight. Further large-scale, well-designed long-term interventional investigations are needed to clarify this issue.

  2. Effect of Continuous Positive Airway Pressure Ventilation on Platelet-activating Factor and Blood Coagulation Function in Patients with Obstructive Sleep Apnea-hypopnea Syndrome

    International Nuclear Information System (INIS)

    Chen Xiangkun; Sheng Chunyong

    2010-01-01

    To investigate the effect of continuous positive airway pressure ventilation (CPAP) on platelet-activating factor (PAF) expression and blood coagulation function in patients with obstructive sleep apnea-hypopnea syndrome (OSAS), the blood sample of 40 patients with OSAS were taken before treatment and on the day 30 after treatment respectively. PAF, thromboxane B 2 (TXB2), prothrombin time (PT), activated partial thromboplastin time (APTT) and fibrin(FIB) in patients and 37 health controls were detected. The results showed that PAF, TXB2, FIB in OSAS patients before treatment were significantly higher than those of after treatment and control group (P 0.05). There were abnormal expression of PAF and hypercoagulability in OSAS patients. CPAP could effectively decrease the expression of PAF, TXB 2 and could also correct dysfunction of blood coagulation. It had certain effect in lightening the clinical symptoms in OSAS patients. (authors)

  3. Self-Reported Napping Behavior Change After Continuous Positive Airway Pressure Treatment in Older Adults with Obstructive Sleep Apnea.

    Science.gov (United States)

    Hsieh, Cheng-Fang; Riha, Renata L; Morrison, Ian; Hsu, Chung-Yao

    2016-08-01

    To assess the effect of continuous positive airway pressure (CPAP) on napping behavior in adults aged 60 and older with obstructive sleep apnea-hypopnea syndrome (OSAHS). Retrospective cohort study using questionnaires. Sleep center. Individuals starting CPAP treatment between April 2010 and March 2012 (mean age 65.2 ± 4.7; M:F = 3.9:1; N = 107). All subjects underwent sleep studies, clinical reviews, and CPAP adherence checks and completed a questionnaire regarding CPAP adherence, current employment status, sleep patterns before and after CPAP, and factors affecting their current sleep patterns. CPAP treatment duration was 82.7 ± 30.0 weeks, and objective adherence was 5.4 ± 2.0 hours per night overall. Daytime nap frequency before CPAP treatment was higher in those with a history of stroke or cardiovascular disease. Both sexes had a significant reduction in daytime napping (men, P napping (men, P nap duration (men, P nap duration was associated with younger age (odds ratio (OR) = 0.86, P = .04), a decrease in ESS score (OR = 1.20, P = .03), and longer self-reported daily nap duration at baseline (OR = 31.52, P nap frequency and daily nap duration. Aging or shorter baseline daily nap duration may attenuate this effect. © 2016, Copyright the Authors Journal compilation © 2016, The American Geriatrics Society.

  4. Sleep architecture, insulin resistance and the nasal cycle: Implications for positive airway pressure therapy

    Directory of Open Access Journals (Sweden)

    Catherine A.P. Crofts

    2018-03-01

    Full Text Available Background: The global pandemic of metabolic disease is worsening. The metabolic theory of obesity proposes that hormonal changes, especially hyperinsulinaemia, precede metabolic disease development. Although quality sleep is recognised as a key factor for good health, less is known about disrupted sleep as a risk factor for hyperinsulinaemia.   Aim: To explore the relationship between sleep, especially sleep architecture and the nasal cycle, on insulin secretion in obstructive sleep apnoea (OSA with comorbid metabolic disease. This review includes a discussion of the potential role of Rest-Activity-Cycler positive airway pressure (RACer-PAP, a novel non-pharmacological OSA treatment strategy.   Methods: A narrative review of all the relevant papers known to the authors was conducted. This review also included results from a polysomnographic sleep clinic pilot study (n = 3 comparing sleep efficiency of RACer-PAP to nasal continuous positive airways pressure (n-CPAP in OSA patients.   Results: Metabolic disease is strongly associated with disturbed sleep. Sleep architecture influences cerebral hormonal secretion, lateral shifts in the autonomic nervous system and nasal airflow dominance. Disturbed sleep shortens short-wave sleep periods, decreasing insulin sensitivity and glucose tolerance. Improvements to metabolic function during n-CPAP treatment are inconsistent. If RACer-PAP demonstrates superior effects on sleep architecture and autonomic function, it may offer advantages in OSA patients with comorbid metabolic disease.   Conclusion: Improving sleep architecture by maintaining the nasal cycle proposes a novel non-pharmacological treatment paradigm for treating OSA with comorbid metabolic disease. Research is required to demonstrate if RACer-PAP therapy influences whole night sleep architecture, sympathovagal balance and markers of metabolic disease.

  5. Evaluation of a new pediatric positive airway pressure mask.

    Science.gov (United States)

    Kushida, Clete A; Halbower, Ann C; Kryger, Meir H; Pelayo, Rafael; Assalone, Valerie; Cardell, Chia-Yu; Huston, Stephanie; Willes, Leslee; Wimms, Alison J; Mendoza, June

    2014-09-15

    The choice and variety of pediatric masks for continuous positive airway pressure (CPAP) is limited in the US. Therefore, clinicians often prescribe modified adult masks. Until recently a mask for children aged mask for children aged 2-7 years (Pixi; ResMed Ltd, Sydney, Australia). Patients aged 2-7 years were enrolled and underwent in-lab baseline polysomnography (PSG) using their previous mask, then used their previous mask and the VPAP III ST-A flow generator for ≥ 10 nights at home. Thereafter, patients switched to the Pixi mask for ≥ 2 nights before returning for a PSG during PAP therapy via the Pixi mask. Patients then used the Pixi mask at home for ≥ 21 nights. Patients and their parents/guardians returned to the clinic for follow-up and provided feedback on the Pixi mask versus their previous mask. AHI with the Pixi mask was 1.1 ± 1.5/h vs 2.6 ± 5.4/h with the previous mask (p = 0.3538). Parents rated the Pixi mask positively for: restfulness of the child's sleep, trouble in getting the child to sleep, and trouble in having the child stay asleep. The Pixi mask was also rated highly for leaving fewer or no marks on the upper lip and under the child's ears, and being easy to remove. The Pixi mask is suitable for children aged 2-7 years and provides an alternative to other masks available for PAP therapy in this age group. © 2014 American Academy of Sleep Medicine.

  6. Clinical predictors of central sleep apnea evoked by positive airway pressure titration

    OpenAIRE

    Bianchi, Matt; Gannon,Karen; Lovell,Kathy; Merlino,Margaret; Mojica,James; Moro,Marilyn

    2016-01-01

    Marilyn Moro,1 Karen Gannon,1 Kathy Lovell,1 Margaret Merlino,1 James Mojica,2 Matt T Bianchi,1,3 1Neurology Department, 2Pulmonary and Critical Care Medicine, Massachusetts General Hospital, Boston, MA, USA; 3Division of Sleep Medicine, Harvard Medical School, Boston, MA, USA Purpose: Treatment-emergent central sleep apnea (TECSA), also called complex apnea, occurs in 5%–15% of sleep apnea patients during positive airway pressure (PAP) therapy, but the clinical predictors are not w...

  7. Effect of continuous positive airway pressure treatment for obstructive sleep apnoea on visual processing of degraded words.

    Science.gov (United States)

    Proudlove, Katie; Manuel, Ari; Hall, Rachel; Rieu, Romelie; Villarroel, Mauricio; Stradling, John

    2014-01-01

    In a previous uncontrolled study, continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea (OSA) improved vision in patients with diabetic macular oedema. We investigated whether the above improvement in vision (or visual processing) might have been due to reduced sleepiness, rather than a true improvement in retinal function. Twelve normal control subjects and 20 patients with OSA were tested for their ability to recognise degraded words, by means of a computer programme displaying 5-letter words every 4 s for 10 min, with variable amounts of the bottom half of the word missing; the percentage of the word necessary to achieve correct identification on average half the time was 'hunted' (the test score). All subjects were tested twice, 2-3 weeks apart; the OSA group after the commencement of CPAP. The Epworth Sleepiness Score (ESS) in patients was measured at the same visit. The test score at visit 1 was 26.7% for normal subjects and 31.6% for patients with OSA. At visit 2, the test score was 25.0% for normal subjects and 29.9% for patients with OSA. The groups showed a small and identical improvement over the trial period in the test score, of 1.7% (p = 0.01 and p = 0.03 for the normal and OSA groups, respectively). The group with OSA experienced a drop in ESS of 7.5 (SD 5.5) points following treatment. The small and identical improvement in both groups suggests only a similar learning effect rather than any improvement due to reduced sleepiness.

  8. [Comparison of efficacy between continuous positive airway pressure and renal artery sympathetic denervation by radiofrequency ablation in obstructive sleep apnea syndrome patients with hypertension].

    Science.gov (United States)

    Zhao, Meng-meng; Tan, Xue-xue; Ding, Ning; Zhang, Xi-long

    2013-04-23

    To compare the efficacy of renal arterial sympathetic denervation (RSD) and continuous positive airway pressure (CPAP) in patients with coexisting moderate-to-severe obstructive sleep apnea syndrome (OSAS) and hypertension. Retrospective analysis was conducted for patients with coexisting moderate to severe OSAS and hypertension for the efficacy of RSD (RSD group, n = 15) and CPAP (CPAP group, n = 16). Comparison was made for polysomnographic parameters and 24 hours ambulatory blood pressure (Bp) between two groups. There was no significant difference in age, gender, body mass index, nocturnal apnea hypopnea index (AHI), mean and minimal pulse oxygen saturation (mean SpO2 and mini SpO2) between two groups. Compared with those at pre-treatment, the following changes were observed at Day 30 post-treatment: in RSD group, the nocturnal AHI and T90 statistically decreased (27 ± 14 vs 32 ± 12, 8.7% ± 7.8% vs 13.8% ± 13.1%, all P 0.05); in CPAP group during treatment, nocturnal AHI and the ratio of duration SpO2 hypertension, both RSD and CPAP may improve sleep respiratory parameters and blood pressure to varying degrees. There is a more significant improvement of nocturnal AHI and SpO2 in CPAP group and more lower MSBp in RSD group.

  9. Plasma apelin levels in obstructive sleep apnea and the effect of continuous positive airway pressure therapy.

    Science.gov (United States)

    Henley, David E; Buchanan, Fiona; Gibson, Rosemary; Douthwaite, Jennie A; Wood, Susan A; Woltersdorf, Wolfram W; Catterall, James R; Lightman, Stafford L

    2009-10-01

    Apelin is a peptide hormone with cardiovascular and glucose homeostasis properties, and obstructive sleep apnea (OSA) is complicated by cardiovascular and metabolic comorbidities. Plasma apelin has not been previously assessed in OSA. We investigated the response of plasma apelin to a 2-h 75 g oral glucose tolerance test (OGTT) and the effect of 3 months compliant continuous positive airway pressure (CPAP) therapy in 15 obese males with newly diagnosed OSA. Plasma apelin and serum cortisol were recorded 10 minutely, while serum insulin and glucose were measured 30 minutely. Ten subjects had plasma apelin measured at intervals across a 24-h period to investigate for circadian variation in apelin levels, and this was repeated following 3 months compliant CPAP therapy. Fasting (0.342+/-0.038 vs 0.288+/-0.024 ng/ml, P=0.04), 30 min (0.399+/-0.035 vs 0.312+/-0.036 ng/ml, P=0.007) and 120 min (0.402+/-0.030 vs 0.259+/-0.024 ng/ml, P<0.001) apelin levels were reduced following CPAP. The area under curve for apelin OGTT response was lower post-CPAP (44.1+/-3.3 vs 35.8+/-2.3 ng/ml per min, P<0.001). Mean OGTT apelin levels showed a significant treatment effect (P=0.006) and a time effect (P<0.001), and the effect of time was different pre- versus post-CPAP (P=0.005). No significant variability in apelin levels existed across the 24-h period at diagnosis. Lower levels were evident overnight following treatment (P=0.004). Improvements in insulin and glucose parameters and reduced cortisol levels were found post-CPAP. In summary, untreated OSA was associated with elevated plasma apelin levels, altered apelin secretory dynamics in response to oral glucose and lack of an apparent circadian variability, which was restored following CPAP.

  10. Development and Implementation of a Training-of-Trainers Program for Continuous Positive Airway Pressure in Neonatal and Pediatric Patients in Five Low- and Middle-Income Countries.

    Science.gov (United States)

    Wilson, Patrick T; Benckert, Megan M; Moresky, Rachel T; Morris, Marilyn C

    2017-10-01

    We describe a pragmatic training-of-trainers program for the use of continuous positive airway pressure (CPAP) for neonatal and pediatric patients. The program is designed for medical professionals working in low- and middle-income countries and involves 2 days of in-class training followed by 1 day of in-service training. The program was created after training in Cambodia, Ghana, Honduras, Kenya and Rwanda and addresses the issues of resource availability, cultural context and local buy-in and partnership in low- and middle-income countries. We hope others will use the training program to increase knowledge and use of CPAP with the ultimate goal of improving neonatal and pediatric survival globally. © The Author [2017]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Improvement in headaches with continuous positive airway pressure for obstructive sleep apnea: a retrospective analysis.

    Science.gov (United States)

    Johnson, Karin G; Ziemba, Alexis M; Garb, Jane L

    2013-02-01

    We aimed to identify clinical features in patients with severe headaches that predicted obstructive sleep apnea (OSA) and determine clinical and sleep study characteristics that predicted headache improvement with continuous positive airway pressure (CPAP). Many patients with headaches complain of sleep symptoms and have OSA. There is often improvement of headaches with CPAP treatment. We conducted a retrospective chart review of all patients referred to adult neurology clinic for headaches and sent for polysomnography between January 2008 and December 2009. Follow-up ranged from 18 to 42 months. Eighty-two headache patients (70 females, 12 males) were studied. Mean age was 45±13 years (females 45±13, males 43±11) and mean body mass index was 32±9. Headache types included 17% chronic migraine without aura, 22% episodic migraine without aura, 32% migraine with aura, 21% tension-type headache, 6% chronic post-traumatic headache, 11% medication overuse headache, and 7% other types. All patients were receiving standard treatment for their headaches by their neurologist. Fifty-two patients (63%) had OSA. Increasing age, female gender, and chronic migraine without aura were predictive of OSA. Of the patients with OSA, 33 (63%) used CPAP and 27 (82%) were adherent to CPAP. Headache improvement was reported by 40 patients (49%) due to either standard medical therapy or CPAP. Patients with OSA who were CPAP adherent (21/27) were more likely to have improvement in headaches than patients intolerant of CPAP (2/6), those that did not try CPAP (8/19), and those who did not have OSA (16/30) (P=.045). Of the 33 patients who used CPAP, 13 reported improvement in headaches specifically due to CPAP therapy and 10 additional patients noted benefit in sleep symptoms. The presence of witnessed apneas (P=.045) and male gender (P=.021) predicted improvement in headaches due to CPAP. Headache patients should be evaluated for the presence of OSA. Treating OSA improves headaches in some

  12. A randomised controlled trial on the effect of mask choice on residual respiratory events with continuous positive airway pressure treatment.

    Science.gov (United States)

    Ebben, Matthew R; Narizhnaya, Mariya; Segal, Alan Z; Barone, Daniel; Krieger, Ana C

    2014-06-01

    It has been found that mask style can affect the amount of continuous positive airway pressure (CPAP) required to reduce an apnoea/hyponoea index (AHI) to mask style to another post titration could affect the residual AHI with CPAP. The purpose of this study was to investigate the differences in residual AHI with CPAP treatment between oronasal and nasal masks. Twenty-one subjects (age mean (M)=62.9, body mass index (BMI) M=29.6 kg/m2) were randomised (14 subjects completed the protocol) to undergo an in-laboratory CPAP titration with either a nasal mask or an oronasal mask. Subjects were then assigned this mask for 3weeks of at-home CPAP use with the optimal treatment pressure determined on the laboratory study (CPAP M=8.4 cm of H2O). At the end of this 3-week period, data were collected from the CPAP machine and the subject was given the other mask to use with the same CPAP settings for the next 3weeks at home (if the nasal mask was given initially, the oronasal one was given later and vice versa). On completion of the second 3-week period, data on residual AHI were again collected and compared with the first 3-week period on CPAP. A Wilcoxon Signed-Rank Test (two-tailed) revealed that residual AHI with CPAP treatment was significantly higher with the oronasal compared with the nasal mask (z = -3.296, pmask, and 50% of the subjects had a residual AHI >10/h in the oronasal mask condition, even though all of these subjects were titrated to an AHI of mask compared with a nasal mask. Switching to an oronasal mask post titration results in an increase in residual AHI with CPAP treatment, and pressure adjustment may be warranted. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Nasal continuous positive airway pressure therapy in a non-tertiary neonatal unit: reduced need for up-transfers.

    Science.gov (United States)

    Kiran, Sai; Murki, Srinivas; Pratap, Oleti Tejo; Kandraju, Hemasree; Reddy, Anupama

    2015-02-01

    To evaluate the need for up-transfer after starting of nasal continuous positive airway pressure (n-CPAP) services in a Level II special newborn care unit (SNCU). Five hundred fifty infants admitted to Level II SNCU, 252 infants during one year prior to introduction of n-CPAP (retrospective data from case records and electronic data base) and 298 infants during one year after introduction of n-CPAP services (prospective data in predefined case reporting form) were evaluated in this before and after intervention trial. The primary outcome was proportion of infants needing up-transfers from Level II SNCU for any indication. Baseline demographic data like birth weight, gestation and other perinatal factors were similar between the two epochs. Among the infants admitted to Level II SNCU, up-transfer for any reason was significantly higher in the pre-CPAP epoch compared with CPAP epoch (n = 93, 36 % vs. n = 74, 24.8 %, p = 0.002, OR 0.56, 95 % CI 0.38 to 0.83). However parent desired up-transfers were similar between the two epochs (n = 9, 3 % vs. n = 16, 5 %, p = 0.40). Introduction of n-CPAP treatment modality reduced up-transfers in subgroups of very low birth weight infants (VLBW) (n = 20, 74 % vs. n = 15, 37 %, p = 0.003) and also in preterm infants (n = 50, 54 % vs. n = 34, 32 %, p = 0.002). Introduction of n-CPAP services in a non-tertiary care neonatal unit, significantly reduced the need for up-transfers, especially in VLBW and preterm infants.

  14. Study into the use of continuous positive airway pressure in obstructive sleep apnoea-hypopnoea syndrome patients with daytime drowsiness

    Directory of Open Access Journals (Sweden)

    Clélia Maria Ribeiro Franco

    2009-03-01

    Full Text Available Background: Obstructive sleep apnoea-hypopnoea syndrome (OSAHS is a respiratory disorder with high morbidity and mortality. Continuous positive airway pressure (CPAP is the most commonly prescribed conservative treatment for adults with OSAHS. CPAP therapy normalises or decreases OSAHS symptoms and can reduce and prevent OSAHS complications. Aims: To evaluate adherence to nasal CPAP treatment and CPAP impact on daytime drowsiness. Method: A sample of 20 patients evaluated for daytime drowsiness using the Epworth sleepiness scale and interviewed for adherence to nasal CPAP use. Results: There was a significant decrease in the level of daytime sleepiness of the patients users of nasal CPAP (p=0.017; patients not using nasal CPAP experienced a decrease without statistical significance (p=0.162. 100% of CPAP users reported benefits and 50% of these reported related discomforts. Conclusions: Patients with OSAHS that use CPAP have a greater reduced level of sleepiness than those who do not use it. Resumo: Introdução: A síndroma da apneia-hipopneia obstrutiva do sono (SAHOS é um distúrbio respiratório de elevada morbimortalidade. A terapia com pressão positiva contínua das vias aéreas (CPAP representa o tratamento conservador mais prescrito para a SAHOS e tem o intuito de restabelecer a patência das vias aéreas, normalizando o índice de eventos respiratórios obstrutivos, corrigindo os sintomas. Objectivo: Avaliar o impacto do uso do CPAP nasal sobre a hipersonia diurna em portadores de SAHOS. Método: Amostra de vinte doentes portadores de SAHOS diagnosticados por estudo de polissonografia de noite inteira, usuários ou não de CPAP nasal, todos avaliados quanto à hipersonia diurna através da escala de sonolência de Epworth. Resultados: O decréscimo do nível de sonolência diurna dos usuários de CPAP nasal foi significante (p=0,017, enquanto para não usuários de CPAP nasal a m

  15. Increasing Humidity Blocks Continuous Positive Airflow-induced Apnea Responses in Rats

    Directory of Open Access Journals (Sweden)

    Ching-Ting Tan

    2010-07-01

    Conclusion: Laryngeal cold dry air stimulation triggered an apneic response, which could be eliminated by humidification but not by the heating of air. These results suggest that using continuous positive airway pressure (CPAP with humidified air decreases CPAP-induced apnea.

  16. The New Perilaryngeal Airway (CobraPLA™)1 Is as Efficient as the Laryngeal Mask Airway (LMA™)2, But Provides Better Airway Sealing Pressures

    Science.gov (United States)

    Akça, Ozan; Wadhwa, Anupama; Sengupta, Papiya; Durrani, Jaleel; Hanni, Keith; Wenke, Mary; Yücel, Yüksel; Lenhardt, Rainer; Doufas, Anthony G.; Sessler, Daniel I.

    2006-01-01

    The Laryngeal Mask Airway (LMA) is a frequently-used efficient airway device, yet it sometimes seals poorly, thus reducing the efficacy of positive-pressure ventilation. The Perilaryngeal Airway (CobraPLA) is a novel airway device with a larger pharyngeal cuff (when inflated). We tested the hypothesis that the CobraPLA was superior to LMA with regard to insertion time and airway sealing pressure and comparable to LMA in airway adequacy and recovery characteristics. After midazolam and fentanyl, 81 ASA I-II outpatients having elective surgery were randomized to receive an LMA or CobraPLA. Anesthesia was induced with propofol (2.5 mg/kg, IV), and the airway inserted. We measured 1) insertion time; 2) adequacy of the airway (no leak at 15-cm-H2O peak pressure or tidal volume of 5 ml/kg); 3) airway sealing pressure; 4) number of repositioning attempts; and 5) sealing quality (no leak at tidal volume of 8 ml/kg). At the end of surgery, gastric insufflation, postoperative sore throat, dysphonia, and dysphagia were evaluated. Data were compared with unpaired t-tests, chi-square tests, or Fisher’s Exact tests; P<0.05 was significant. Patient characteristics, insertion times, airway adequacy, number of repositioning attempts, and recovery were similar in each group. Airway sealing pressure was significantly greater with CobraPLA (23±6 cm H2O) than LMA (18±5 cm H2O, P<0.001). The CobraPLA has insertion characteristics similar to LMA, but better airway sealing capabilities. PMID:15281543

  17. Impact of the type of mask on the effectiveness of and adherence to continuous positive airway pressure treatment for obstructive sleep apnea*

    Science.gov (United States)

    de Andrade, Rafaela Garcia Santos; Piccin, Vivien Schmeling; Nascimento, Juliana Araújo; Viana, Fernanda Madeiro Leite; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2014-01-01

    Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect. PMID:25610507

  18. Impact of the type of mask on the effectiveness of and adherence to continuous positive airway pressure treatment for obstructive sleep apnea.

    Science.gov (United States)

    Andrade, Rafaela Garcia Santos de; Piccin, Vivien Schmeling; Nascimento, Juliana Araújo; Viana, Fernanda Madeiro Leite; Genta, Pedro Rodrigues; Lorenzi-Filho, Geraldo

    2014-01-01

    Continuous positive airway pressure (CPAP) is the gold standard for the treatment of obstructive sleep apnea (OSA). Although CPAP was originally applied with a nasal mask, various interfaces are currently available. This study reviews theoretical concepts and questions the premise that all types of interfaces produce similar results. We revised the evidence in the literature about the impact that the type of CPAP interface has on the effectiveness of and adherence to OSA treatment. We searched the PubMed database using the search terms "CPAP", "mask", and "obstructive sleep apnea". Although we identified 91 studies, only 12 described the impact of the type of CPAP interface on treatment effectiveness (n = 6) or adherence (n = 6). Despite conflicting results, we found no consistent evidence that nasal pillows and oral masks alter OSA treatment effectiveness or adherence. In contrast, most studies showed that oronasal masks are less effective and are more often associated with lower adherence and higher CPAP abandonment than are nasal masks. We concluded that oronasal masks can compromise CPAP OSA treatment adherence and effectiveness. Further studies are needed in order to understand the exact mechanisms involved in this effect.

  19. [Effect of Continuous Positive Airway Pressure Treatment on Depression, Anxiety and Perceived Stress Levels in Patients with Obstructive Sleep Apnea Syndrome].

    Science.gov (United States)

    Çelik, Mustafa; Sarıkaya, Yasin; Acar, Mustafa; Kalenderoğlu, Aysun; Doğan, Sedat; Kaskalan, Emin; Karataş, Mehmet

    2016-01-01

    The aim of this study is to determine the effects of continuous positive airway pressure (CPAP) treatment on depression, anxiety, and perceived stress levels and to identify factors predictive of treatment efficacy in patients with obstructive sleep apnea syndrome (OSAS). This study included 51 patients admitted to the Adiyaman University Medical School Otorhinolaryngology Department or Eskisehir Yunus Emre State Hospital between January and September 2014 with one or more complaints including snoring, excessive daytime sleepiness, or apnea witnessed by the partner. Diagnosis of OSAS was made by polysomnography and CPAP treatment was initiated. Depression levels were assessed in all study subjects using the Hospital Anxiety and Depression Scale (HADS) at the start of treatment and at 3 months. Anxiety levels were assessed using both the HADS and the State and Trait Anxiety Inventory (STAI), and perceived stress level was assessed using the Perceived Stress Questionnaire (PSQ). After CPAP treatment, we observed significant decreases in both the Depression and Anxiety Subscales of the HADS, in the Trait Anxiety subscale of the STAI, and in the PSQ. An evaluation of the initial parameters that predict improvements in these scales revealed that snoring time predicted decreases in all scale scores. In OSAS patients CPAP treatment has positive effects on psychological parameters like depression, anxiety, and perceived stress. We suggest that possible psychogenic benefits should be considered when deciding to start CPAP treatment, particularly in patients with pronounced and extended snoring who may also have social problems.

  20. Non-invasive positive pressure ventilation for acute asthma in children

    DEFF Research Database (Denmark)

    Korang, Steven Kwasi; Feinberg, Joshua; Wetterslev, Jørn

    2016-01-01

    (age independently screened titles and abstracts. We retrieved all relevant full-text study reports, independently screened the full text, identified trials for inclusion and identified and recorded...... reasons for exclusion of ineligible trials. We resolved disagreements through discussion or, if required, consulted a third review author. We recorded the selection process in sufficient detail to complete a PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) flow diagram...... both studies as having high risk of bias; both trials assessed effects of bilateral positive airway pressure (BiPAP). Neither trial used continuous positive airway pressure (CPAP). Controls received standard care. Investigators reported no deaths and no serious adverse events (Grades of Recommendation...

  1. Effects of continuous positive airway pressure on hemorheology and serum inflammatory factors in patients with obstructive sleep apnea hypopnea syndrome

    Directory of Open Access Journals (Sweden)

    Ye-Jun Liu

    2016-02-01

    Full Text Available Objective: To investigate the effects of continuous positive airway pressure (CPAP on hemorheology and serum inflammatory factors in patients with obstructive sleep apnea hypopnea syndrome (OSAHS. Methods: A total of 87 patients with moderate and severe OSAHS from Department of Otolaryngology-Head and Neck Surgery of South Central Hospital of Wuhan University and Qianjiang Central Hospital were selected as research objects in the treatment group, while 37 healthy individuals were chosen as objects in the control group. The changes of hemorheology indexes including hematocrit (HCT, whole blood viscosity, platelet aggregation (PAG and endothelin (ET as well as serum inflammatory factors including interleukin-6 (IL-6, IL-18 and tumor necrosis factor-α (TNF-α were measured in the control group and the treatment group, and comparisons involving these indexes were made between the two groups. Results: Before treatment, the hemorheology indexes HCT, whole blood viscosity (high, medium and low sheer rates, PAG and ET as well as the inflammatory factors IL-6, IL-18 and TNF-α levels were significantly higher than those in the control group; after CPAP treatment, all these indexed mentioned above in the treatment group were significantly decreased compared with before treatment. Conclusion: CPAP treatment has a reliable therapeutic effect on OSAHS patients, which can obviously improve the hemorheology and largely reduce the inflammatory response.

  2. Restoring the salivary cortisol awakening response through nasal continuous positive airway pressure therapy in obstructive sleep apnea.

    Science.gov (United States)

    Ghiciuc, Cristina Mihaela; Dima Cozma, Lucia Corina; Bercea, Raluca Mihaela; Lupusoru, Catalina Elena; Mihaescu, Traian; Szalontay, Andreea; Gianfreda, Angela; Patacchioli, Francesca Romana

    2013-10-01

    Partial and largely conflicting data are currently available on the interplay between obstructive sleep apnea (OSA) and hypothalamus-pituitary-adrenal axis (HPA) activity in adult obese men. This study was performed to evaluate the daily trajectories of salivary cortisol, specifically with respect to the salivary cortisol awakening response (CAR), a common method used to assess HPA axis activity. The main findings of this study were that adult male obese subjects who were newly diagnosed with severe OSA showed the following: (1) a flattening of the CAR; (2) levels of cortisol at awakening that were lower than those of the controls; and (3) maintenance of the physiological circadian activity of the HPA axis, with the highest hormone concentrations produced in the morning and the lowest in the evening. This study was also designed to investigate the effects of 3 and 6 mos of treatment with continuous airways positive pressure (CPAP). CPAP use resulted in a significant recovery of the sleep patterns disrupted by OSA; moreover, mild neuropsychological signs of depression and anxiety in severe OSA patients were concomitantly progressively improved by CPAP treatment. Furthermore, this study reports that 3 and 6 mos of CPAP therapy restored the presence of CAR and was able to significantly reduce the difference in the morning cortisol levels between the OSA and control groups. In conclusion, we report here that compared with obese nonapneic matched controls, OSA patients present a dysregulation of HPA axis activity, as shown by the flattening of the diurnal pattern of cortisol production in response to repeated challenge due to hypoxia and sleep fragmentation. This dysregulation was especially detectable in the first hour after awakening and restored after 3 and 6 mos of treatment with CPAP.

  3. Effects of Heated Humidification and Topical Steroids on Compliance, Nasal Symptoms, and Quality of Life in Patients with Obstructive Sleep Apnea Syndrome Using Nasal Continuous Positive Airway Pressure

    Science.gov (United States)

    Ryan, Silke; Doherty, Liam S.; Nolan, Geraldine M.; McNicholas, Walter T.

    2009-01-01

    Background: Nasal side effects are common in patients with obstructive sleep apnea syndrome (OSAS) starting on nasal continuous positive airway pressure (CPAP) therapy. We tested the hypothesis that heated humidification or nasal topical steroids improve compliance, nasal side effects and quality of life in this patient group. Methods: 125 patients with the established diagnosis of OSAS (apnea/hypopnea index ≥ 10/h), who tolerated CPAP via a nasal mask, and who had a successful CPAP titration were randomized to 4 weeks of dry CPAP, humidified CPAP or CPAP with additional topical nasal steroid application (fluticasone, GlaxoWellcome). Groups were similar in all demographic variables and in frequency of nasal symptoms at baseline. Outcome measures were objective compliance, quality of life (short form 36), subjective sleepiness (Epworth Sleepiness Scale score) and nasal symptoms such as runny, dry or blocked nose, sneezing and headaches; all variables assessed using a validated questionnaire and by direct interview. Results: There was no difference in compliance between groups after 4 weeks (dry: 5.21 ± 1.66 h/night, fluticasone: 5.66 ± 1.68, humidifier: 5.21 ± 1.84; p = 0.444). Quality of life and subjective sleepiness improved in all groups, but there were no differences in the extent of improvement. Nasal Symptoms were less frequently reported in the humidifier group (28%) than in the remaining groups (dry: 70%, fluticasone: 53%, p = 0.002). However, the addition of fluticasone resulted in increased frequency of sneezing. Conclusion: The addition of a humidifier, but not nasal steroids decreases the frequency of nasal symptoms in unselected OSAS patients initiating CPAP therapy; however compliance and quality of life remain unaltered. Citation: Ryan S; Doherty LS; Nolan GM; McNicholas WT. Effects of heated humidification and topical steroids on compliance, nasal symptoms, and quality of life in patients with obstructive sleep apnea syndrome using nasal

  4. Symptoms of insomnia among patients with obstructive sleep apnea before and after two years of positive airway pressure treatment.

    Science.gov (United States)

    Björnsdóttir, Erla; Janson, Christer; Sigurdsson, Jón F; Gehrman, Philip; Perlis, Michael; Juliusson, Sigurdur; Arnardottir, Erna S; Kuna, Samuel T; Pack, Allan I; Gislason, Thorarinn; Benediktsdóttir, Bryndis

    2013-12-01

    To assess the changes of insomnia symptoms among patients with obstructive sleep apnea (OSA) from starting treatment with positive airway pressure (PAP) to a 2-y follow-up. Longitudinal cohort study. Landspitali--The National University Hospital of Iceland. There were 705 adults with OSA who were assessed prior to and 2 y after starting PAP treatment. PAP treatment for OSA. All patients underwent a medical examination along with a type 3 sleep study and answered questionnaires on health and sleep before and 2 y after starting PAP treatment. The change in prevalence of insomnia symptoms by subtype was assessed by questionnaire and compared between individuals who were using or not using PAP at follow-up. Symptoms of middle insomnia were most common at baseline and improved significantly among patients using PAP (from 59.4% to 30.7%, P insomnia tended to persist regardless of PAP treatment, and symptoms of late insomnia were more likely to improve among patients not using PAP. Patients with symptoms of initial and late insomnia at baseline were less likely to adhere to PAP (odds ratio [OR] 0.56, P = 0.007, and OR 0.53, P insomnia. Symptoms of initial and late insomnia, however, tended to persist regardless of positive airway pressure treatment and had a negative effect on adherence. Targeted treatment for insomnia may be beneficial for patients with obstructive sleep apnea comorbid with insomnia and has the potential to positively affect adherence to positive airway pressure.

  5. Effects of continuous positive airway pressure on energy intake in obstructive sleep apnea: A pilot sham-controlled study

    Science.gov (United States)

    Shechter, Ari; Kovtun, Kyle; St-Onge, Marie-Pierre

    2016-01-01

    Obesity is among the leading risk factors for obstructive sleep apnea (OSA). A reciprocal relationship between obesity and OSA has been proposed, which may be due to excessive food intake. We conducted a pilot study to test the effects of continuous positive airway pressure (CPAP) on energy intake (EI) in OSA patients using a sham-controlled crossover design. In-laboratory total daily EI was assessed after 2 mo of active and sham CPAP. Four men were enrolled (age ± SEM: 51.8 ± 2.1 y; body mass index: 31.5 ± 1.5 kg/m2). All received active treatment first. Meals (breakfast, lunch, dinner, snack) were served in excess portions at fixed times and additional palatable snacks were freely available throughout the day. Total EI was lower after active (3744 ± 511 kcal/d) vs. sham (4030 ± 456 kcal/d) CPAP but this difference was not significant (p = 0.51) due to variability in the free snack intake. When only fixed eating occasions were considered, daily EI was significantly lower in the active (3105 ± 513 kcal/d) vs. sham (3559 ± 420 kcal/d) condition (p = 0.006). This small pilot and feasibility study is the first to utilize a sham-controlled design to investigate the effects of CPAP treatment on objective measures of EI. Findings suggest that CPAP may cause a reduction in fixed meal intake. In demonstrating feasibility of study methodology, our study also suggests a larger randomized sham-controlled trial be conducted to fully characterize the effects of CPAP treatment on EI and energy balance overall. PMID:27769851

  6. Obstructive sleep apnea is associated with increased QT corrected interval dispersion: the effects of continuous positive airway pressure.

    Science.gov (United States)

    Bilal, Nagihan; Dikmen, Nursel; Bozkus, Fulsen; Sungur, Aylin; Sarica, Selman; Orhan, Israfil; Samur, Anil

    2017-03-31

    Severe obstructive sleep apnea (OSA) is associated with increased QT corrected interval dispersion (QTcd) and continuous positive airway pressure (CPAP) is thought to improve this arrhythmogenic marker. The aim of the study was to determine the decrease of ratio of cardiovascular risk in patients with obstructive sleep apnea. The study included 65 patients with severe OSA who had an apnea-hypopnea index (AHI) score of >30. Each patient underwent 12-channel electrocardiogram (ECG) monitoring and polysomnography. Patients with an AHI score of <5 were used as the control group. The control group also underwent ECG monitoring and polysomnography testing. The QTcd levels of both groups were calculated. Three months after CPAP treatment, ECG recordings were obtained from the 65 patients with severe OSA again, and their QTcd values were calculated. There were 44 male and 21 female patients with severe OSA syndrome. The age, gender, body mass index, initial saturation, minimum saturation, average saturation, and desaturation index were determined in both groups. The QTc intervals of the OSA patients (62.48±16.29ms) were significantly higher (p=0.001) than those of the control group (29.72±6.30ms). There were statistically significant differences between the QTc values before and after the CPAP treatment, with pretreatment QTc intervals of 62.48±16.29ms and 3-month post-treatment values of 41.42±16.96ms (p=0.001). There was a positive and significant correlation between QTcd periods and the AHI and hypopnea index (HI) in OSA patients (p=0.001; r=0.71; p=0.001; r=0.679, respectively). CPAP treatment reduced the QTcd in patients with severe OSA. In addition, shortening the QTcd periods in patients with severe OSA may reduce their risk of arrhythmias and cardiovascular disease. Copyright © 2017 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  7. Absence of effect of nasal continuous positive airway pressure on the esophageal phase of nutritive swallowing in newborn lambs.

    Science.gov (United States)

    Djeddi, Djamal; Cantin, Danny; Samson, Nathalie; Tian, Hao; Praud, Jean-Paul

    2013-08-01

    It is presently recommended that oral feeding be started in premature infants as soon as possible, often at an age at which nasal continuous positive airway pressure (nCPAP) is still required for ventilatory support. Our previous data showed that application of nCPAP up to 10 cmH2O in full-term lambs had no deleterious effect on cardiorespiratory safety, feeding efficiency, or on nutritive swallowing-breathing coordination. Besides fear of swallowing-breathing coordination disturbances, esophageal motility disruption by nCPAP could be a reason to delay oral feeding. To our knowledge, no study has focused on the effects of nCPAP on esophageal motility in the neonatal period. The aim of the present study was therefore to further assess the effects of nCPAP on oral feeding by assessing its effects on the esophageal phase of nutritive swallowing (nutritive esophagodeglutition). Six full-term lambs, ages 2 to 3 days, underwent esophageal multichannel intraluminal impedance-pH monitoring. Lambs were bottle-fed under 2 randomized conditions, namely spontaneous breathing and nCPAP 6 cmH(2)O. Beyond confirmation of unaltered feeding efficiency, analysis of multiple variables measured by impedance monitoring revealed that nCPAP 6 does not alter nutritive esophagodeglutition in any way (nCPAP vs spontaneous breathing, P > 0.1 for all variables). offering further support to neonatologists pleading for initiation of oral feeding in infants still on nCPAP, the present results set the foundations for similar clinical studies in preterm human infants to confirm the absence of effects of nCPAP on nutritive swallowing.

  8. A randomised controlled trial of flow driver and bubble continuous positive airway pressure in preterm infants in a resource-limited setting.

    Science.gov (United States)

    Mazmanyan, P; Mellor, K; Doré, C J; Modi, N

    2016-01-01

    The variable-flow flow driver (FD; EME) and continuous-flow bubble (Fisher-Paykel) continuous positive airway pressure (CPAP) systems are widely used. As these differ in cost and technical requirements, determining comparative efficacy is important particularly where resources are limited. We performed a randomised, controlled, equivalence trial of CPAP systems. We specified the margin of equivalence as 2 days. We analysed binary variables by logistical regression adjusted for gestation, and log transformed continuous variables by multiple linear regression adjusted for gestation, sex and antenatal steroids. A neonatal unit with no blood gas analyser or surfactant availability and limited X-ray and laboratory facilities Neonates CPAP at delivery followed by randomisation to FD or bubble (B). Primary outcome included total days receiving CPAP; secondary outcomes included days receiving CPAP, supplemental oxygen, ventilation, death, pneumothorax and nasal excoriation. We randomised 125 infants (B 66, FD 59). Differences in infant outcomes on B and FD were not statistically significant. The median (range) for CPAP days for survivors was B 0.8 (0.04 to 17.5), FD 0.5 (0.04 to 5.3). B:FD (95% CI) ratios were CPAP days 1.3 (0.9 to 2.1), CPAP plus supplementary oxygen days 1.2 (0.7 to 1.9). B:FD (95% CI) ORs were death 2.3 (0.2 to 28), ventilation 2.1 (0.5 to 9), nasal excoriation 1.2 (0.2 to 8) and pneumothorax 2.4 (0.2 to 26). In a resource-limited setting we found B CPAP equivalent to FD CPAP in the total number of days receiving CPAP within a margin of 2 days. ISRCTN22578364. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  9. The Effect of Non-nutritive Sucking on Transcutaneous Oxygen Saturation in Neonates under the Nasal Continuous Positive Airway Pressure (CPAP

    Directory of Open Access Journals (Sweden)

    Mousa Ahmadpour-kacho

    2017-03-01

    Full Text Available BackgroundSeveral beneficial effects of non-nutritive sucking in infants, including the physiological stability, relaxation, better transition from tube feeding to oral feeding have been reported. But its effect on oxygen saturation in neonates under the Nasal Continuous Positive Airway Pressure (NCPAPو (is not so clear. This study aimed to investigate the effects of non-nutritive sucking on transcutaneous oxygen saturation levels of neonates treated with NCPAP.Materials and MethodsThis quasi-experimental study was done on 25 preterm neonates, hospitalized with a diagnosis of respiratory distress, required NCPAP, in the neonatal intensive care unit (NICU at the Ayatollah Rouhani Hospital and Babol Clinic, North of Iran. Non-nutritive sucking was elicited by a standard pacifier appropriate to their age one hour a day, and the mean oxygen saturation was measured before and after intervention by cardiopulmonary monitoring (Saadat Co., Iran. Data analyzed using SPSS-18.0 software.ResultsIn the 25 cases studied, the mean oxygen saturation values ​​before performing non-nutritive sucking was 96.31±2.88%, which was changed to 98.35±1.6% after intervention, and this increase was statistically significant (P = 0.004.Results showed that the gender, birth weight and gestational age of neonates had no effect on mean Blood oxygen saturation (SpO2level.ConclusionAccording to the results, using the non-nutritive sucking in premature neonates under the NCPAP, can improve oxygenation.

  10. Impact of Compression Stockings vs. Continuous Positive Airway Pressure on Overnight Fluid Shift and Obstructive Sleep Apnea among Patients on Hemodialysis

    Directory of Open Access Journals (Sweden)

    Bruno C. Silva

    2017-05-01

    Full Text Available IntroductionObstructive sleep apnea (OSA is common in edematous states, notably in hemodialysis patients. In this population, overnight fluid shift can play an important role on the pathogenesis of OSA. The effect of compression stockings (CS and continuous positive airway pressure (CPAP on fluid shift is barely known. We compared the effects of CS and CPAP on fluid dynamics in a sample of patients with OSA in hemodialysis, through a randomized crossover study.MethodsEach participant performed polysomnography (PSG at baseline, during CPAP titration, and after 1 week of wearing CS. Neck circumference (NC and segmental bioelectrical impedance were done before and after PSG.ResultsFourteen patients were studied (53 ± 9 years; 57% men; body mass index 29.7 ± 6.8 kg/m2. Apnea–hypopnea index (AHI decreased from 20.8 (14.2; 39.6 at baseline to 7.9 (2.8; 25.4 during CPAP titration and to 16.7 (3.5; 28.9 events/h after wearing CS (CPAP vs. baseline, p = 0.004; CS vs. baseline, p = 0.017; and CPAP vs. CS, p = 0.017. Nocturnal intracellular trunk water was higher after wearing CS in comparison to baseline and CPAP (p = 0.03. CS reduced the fluid accumulated in lower limbs during the day, although not significantly. Overnight fluid shift at baseline, CPAP, and CS was −183 ± 72, −343 ± 220, and −290 ± 213 ml, respectively (p = 0.006. Overnight NC increased at baseline (0.7 ± 0.4 cm, decreased after CPAP (−1.0 ± 0.4 cm, and while wearing CS (−0.4 ± 0.8 cm (CPAP vs. baseline, p < 0.0001; CS vs. baseline, p = 0.001; CPAP vs. CS, p = 0.01.ConclusionCS reduced AHI by avoiding fluid retention in the legs, favoring accumulation of water in the intracellular component of the trunk, thus avoiding fluid shift to reach the neck. CPAP improved OSA by exerting local pressure on upper airway, with no impact on fluid redistribution. CPAP performed significantly better than CS

  11. Comparison of three continuous positive airway pressure (CPAP) interfaces in healthy Beagle dogs during medetomidine-propofol constant rate infusions.

    Science.gov (United States)

    Meira, Carolina; Joerger, Fabiola B; Kutter, Annette P N; Waldmann, Andreas; Ringer, Simone K; Böehm, Stephan H; Iff, Samuel; Mosing, Martina

    2018-03-01

    To compare the efficacy of three continuous positive airway pressure (CPAP) interfaces in dogs on gas exchange, lung volumes, amount of leak during CPAP and rebreathing in case of equipment failure or disconnection. Randomized, prospective, crossover, experimental trial. Ten purpose-bred Beagle dogs. Dogs were in dorsal recumbency during medetomidine-propofol constant rate infusions, breathing room air. Three interfaces were tested in each dog in a consecutive random order: custom-made mask (M), conical face mask (FM) and helmet (H). End-expiratory lung impedance (EELI) measured by electrical impedance tomography was assessed with no interface (baseline), with the interface only (No-CPAP for 3 minutes) and at 15 minutes of 7 cmH 2 O CPAP (CPAP-delivery). PaO 2 was assessed at No-CPAP and CPAP-delivery, partial pressure of inspired carbon dioxide (PICO 2 ; rebreathing assessment) at No-CPAP and the interface leak (ΔP leak ) at CPAP-delivery. Mixed-effects linear regression models were used for statistical analysis (pCPAP-delivery, all interfaces increased EELI by 7% (pCPAP, less rebreathing occurred with M (0.5 kPa, 4 mmHg) than with FM (1.8 kPa, 14 mmHg) and with H (1.4 kPa, 11 mmHg), but also lower PaO 2 was measured with M (9.3 kPa, 70 mmHg) than with H (11.9 kPa, 90 mmHg) and FM (10.8 kPa, 81 mmHg). All three interfaces can be used to provide adequate CPAP in dogs. The leak during CPAP-delivery and the risk of rebreathing and hypoxaemia, when CPAP is not maintained, can be significant. Therefore, animals should always be supervised during administration of CPAP with any of the three interfaces. The performance of the custom-made M was not superior to the other interfaces. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.

  12. Efficacy of the addition of positive airway pressure to conventional chest physiotherapy in resolution of pleural effusion after drainage: protocol for a randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Elinaldo da Conceição dos Santos

    2015-04-01

    Discussion: Conventional chest physiotherapy and intermittent positive airway pressure breathing are widely indicated for people with pleural effusion and chest drains; however, no studies have evaluated the real benefit of this type of treatment. Our hypothesis is that optimised lung expansion achieved through the application of intermittent positive airway pressure will accelerate the reabsorption of pleural effusion, decrease the duration of chest drainage and respiratory system impairment, reduce the length of hospital stay, and reduce the incidence of pulmonary complications.

  13. Effectiveness and safety of a prehospital program of continuous positive airway pressure (CPAP) in an urban setting.

    Science.gov (United States)

    Willmore, Andrew; Dionne, Richard; Maloney, Justin; Ouston, Ed; Stiell, Ian

    2015-11-01

    Continuous positive airway pressure (CPAP) is commonly used in the treatment of acute cardiogenic pulmonary edema (ACPE) and acute exacerbations of chronic obstructive pulmonary disease (AECOPD). In-hospital evidence is robust: CPAP has been shown to improve respiratory status and to reduce intubation rates. There is less evidence on prehospital CPAP, although the emergency medical services (EMS) adoption of this modality is increasing. The objectives of this study were to 1) measure the effectiveness of prehospital CPAP on morbidity, mortality, and transport times; and 2) audit the selection of patients by medics for appropriateness and safety. We conducted a before-and-after study from August 1 to October 31 in 2010 and 2011, before and after the implementation of prehospital CPAP in a city of one million people with large rural areas. Medics were trained to apply CPAP to patients with respiratory distress and a presumed diagnosis of ACPE or AECOPD. Charts were selected using the search criteria of the chief complaint of shortness of breath, emergent transport to hospital, and any patients receiving CPAP in the field. Data extracted from ambulance call reports and hospital records were analysed with appropriate univariate statistics. A total of 373 patients enrolled (186 pre-non-invasive ventilation [NIV] and 187 post-NIV), mean age 71.5 years, female 51.4%, and final diagnoses of ACPE 18.9%, AECOPD 21.9%. In the post group of 84 patients meeting NIV criteria, 41.6% received NIV; and of 102 patients not meeting the criteria, 5.2% received NIV. There were 12 minor adverse events in 36 applications (33.3%) as per protocol. Comparing post versus pre, there were higher rates of emergency department (ED) NIV (20.0% v. 13.4%, pCPAP in our prehospital setting with respect to morbidity, mortality, and length of stay. EMS must exercise caution in making the decision to invest in the equipment and training required to implement prehospital CPAP.

  14. Effects of a short course of eszopiclone on continuous positive airway pressure adherence: a randomized trial.

    Science.gov (United States)

    Lettieri, Christopher J; Shah, Anita A; Holley, Aaron B; Kelly, William F; Chang, Audrey S; Roop, Stuart A

    2009-11-17

    Adherence to short-term continuous positive airway pressure (CPAP) may predict long-term use. Unfortunately, initial CPAP intolerance may lead to poor adherence or abandonment of therapy. To determine whether a short course of eszopiclone at the onset of therapy improves long-term CPAP adherence more than placebo in adults with obstructive sleep apnea. Parallel randomized, placebo-controlled trial from March 2007 to December 2008. Randomization, maintained and concealed centrally by pharmacy personnel, was computer-generated using fixed blocks of 10. Referring physicians, investigators, and patients were blinded to the treatment assignment until after the final data were collected. (ClinicalTrials.gov registration number: NCT00612157). Academic sleep disorder center. 160 adults (mean age, 45.7 years [SD, 7.3]; mean apnea-hypopnea index, 36.9 events/h [SD, 23]) with newly diagnosed obstructive sleep apnea initiating CPAP. Eszopiclone, 3 mg (n = 76), or matching placebo (n = 78) for the first 14 nights of CPAP. Use of CPAP was measured weekly for 24 weeks. Adherence to CPAP (primary outcome) and the rate of CPAP discontinuation and improvements in symptoms (secondary outcomes) were compared. Follow-up at 1, 3, and 6 months was completed by 150, 136, and 120 patients, respectively. Patients in the eszopiclone group used CPAP for 20.8% more nights (95% CI, 7.2% to 34.4%; P = 0.003), 1.3 more hours per night for all nights (CI, 0.4 to 2.2 hours; P = 0.005), and 1.1 more hours per night of CPAP use (CI, 0.2 to 2.1 hours; P = 0.019). The hazard ratio for discontinuation of CPAP was 1.90 (CI, 1.1 to 3.4; P = 0.033) times higher in the placebo group. Side effects were reported in 7.1% of patients and did not differ between groups. Patients had severe obstructive sleep apnea treated at a specialized sleep center with frequent follow-up; results may not be generalizable to different settings. Patients' tolerance to CPAP and their reasons for discontinuation were not assessed

  15. The use of continuous positive airway pressure in preterm babies with respiratory distress syndrome: a report from Baghdad, Iraq.

    Science.gov (United States)

    Hameed, Numan Nafie; Abdul Jaleel, Ra'id Khalil; Saugstad, Ola Didrik

    2014-04-01

    To study maternal and neonatal risk factors related to outcome of preterm babies with respiratory distress syndrome (RDS) on Continuous Positive Airway Pressure (CPAP) in a tertiary Iraqi NICU. A prospective case study carried out from January 5, 2011 to January 5, 2012, on 70 preterm neonates with RDS who were started on CPAP. Maternal and infant variables of preterm babies with successful or failed CPAP therapy were compared. Seventy neonates, 44 (63%) males and 26 (37%) females were included. Mean (SD) gestation was 32.8 (2.8) weeks and mean (SD) birth weight was 1860 (656) g. Thirty-seven (52.9%) babies failed CPAP, of them 29 (78.3%) were started on mechanical ventilation. The variables associated with failure of CPAP were: Birth weight ≤1500 g, gestational age ≤30 weeks, white out on the chest X-ray, FiO2 ≥50% at 20 min of CPAP, PEEP ≥5.5 cm H2O. Mortality rates were 94.6% in CPAP failures versus 5.4% in CPAP successes (p = 0.001). In infants surviving till discharge, duration of hospital stay was longer in babies who were CPAP successes (9.6 ± 3.7 versus 3.0 ± 2.7 days, p = 0.001). Gestational age, birth weight, whiteout chest X-ray, and FiO2 are important predictive values for success of CPAP therapy. A larger prospective multicenter controlled trial is needed to determine the benefits and risks of CPAP and predictors of its failure in our setting. Our results may be useful for others practicing in similar settings as us.

  16. Influence of Head and Neck Position on Oropharyngeal Leak Pressure and Cuff Position with the ProSeal Laryngeal Mask Airway and the I-Gel: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Mishra

    2015-01-01

    Full Text Available Background. This study was designed to assess and compare the effect of head and neck position on the oropharyngeal leak pressures and cuff position (employing fibreoptic view of the glottis and ventilation scores between ProSeal LMA and the I-gel. Material and Methods. After induction of anesthesia, the supraglottic device was inserted and ventilation confirmed. The position of the head was randomly changed from neutral to flexion, extension, and lateral rotation (left. The oropharyngeal leak pressures, fibreoptic view of glottis, ventilation scores, and delivered tidal volumes and end tidal CO2 were noted in all positions. Results. In both groups compared with neutral position, oropharyngeal leak pressures were significantly higher with flexion and lower with extension but similar with rotation of head and neck. However the oropharyngeal leak pressure was significantly higher for ProSeal LMA compared with the I-gel in all positions. Peak airway pressures were significantly higher with flexion in both groups (however this did not affect ventilation, lower with extension in ProSeal group, and comparable in I-gel group but did not change significantly with rotation of head and neck in both groups. Conclusion. Effective ventilation can be done with both ProSeal LMA and I-gel with head in all the above positions. ProSeal LMA has a better margin of safety than I-gel due to better sealing pressures except in flexion where the increase in airway pressure is more with the former. Extreme precaution should be taken in flexion position in ProSeal LMA.

  17. Boussignac continuous positive airway pressure for the management of acute cardiogenic pulmonary edema: prospective study with a retrospective control group

    Directory of Open Access Journals (Sweden)

    Aarts Leon PHJ

    2007-12-01

    Full Text Available Abstract Background Continuous positive airway pressure (CPAP treatment for acute cardiogenic pulmonary edema can have important benefits in acute cardiac care. However, coronary care units are usually not equipped and their personnel not adequately trained for applying CPAP with mechanical ventilators. Therefore we investigated in the coronary care unit setting the feasibility and outcome of the simple Boussignac mask-CPAP (BCPAP system that does not need a mechanical ventilator. Methods BCPAP was introduced in a coronary care unit where staff had no CPAP experience. All consecutive patients transported to our hospital with acute cardiogenic pulmonary edema, a respiratory rate > 25 breaths/min and a peripheral arterial oxygen saturation of Results During the 2-year prospective BCPAP study period 108 patients were admitted with acute cardiogenic pulmonary edema. Eighty-four of these patients (78% were treated at the coronary care unit of which 66 (61% were treated with BCPAP. During the control period 66 patients were admitted over a 1-year period of whom 31 (47% needed respiratory support in the intensive care unit. BCPAP treatment was associated with a reduced hospital length of stay and fewer transfers to the intensive care unit for intubation and mechanical ventilation. Overall estimated savings of approximately € 3,800 per patient were achieved with the BCPAP strategy compared to conventional treatment. Conclusion At the coronary care unit, BCPAP was feasible, medically effective, and cost-effective in the treatment of acute cardiogenic pulmonary edema. Endpoints included mortality, coronary care unit and hospital length of stay, need of ventilatory support, and cost (savings.

  18. Efficacy of Bilevel-auto Treatment in Patients with Obstructive Sleep Apnea Not Responsive to or Intolerant of Continuous Positive Airway Pressure Ventilation.

    Science.gov (United States)

    Carlucci, Annalisa; Ceriana, Piero; Mancini, Marco; Cirio, Serena; Pierucci, Paola; D'Artavilla Lupo, Nadia; Gadaleta, Felice; Morrone, Elisa; Fanfulla, Francesco

    2015-09-15

    Ventilation with continuous positive airway pressure (CPAP) is the gold standard therapy for obstructive sleep apnea (OSA). However, it was recently suggested that a novel mode of ventilation, Bilevel-auto, could be equally effective in treating patients unable to tolerate CPAP. The aim of this study was to investigate the ability of Bilevel-auto to treat OSA patients whose nocturnal ventilatory disturbances are not completely corrected by CPAP. We enrolled 66 consecutive OSA patients, not responsive to (group A) or intolerant of (group B) CPAP treatment, after a full night of manual CPAP titration in a laboratory. Full polysomnography data and daytime sleepiness score were compared for each group in the three different conditions: basal, during CPAP, and during Bilevel-auto. The apnea-hypopnea index decreased significantly during CPAP in both groups; however, in the group A, there was a further significant improvement during Bilevel-auto. The same trend was observed for oxygenation indices, while the distribution and the efficiency of sleep did not differ following the switch from CPAP to Bilevel-auto. This study confirmed the role of Bilevel-auto as an effective therapeutic alternative to CPAP in patients intolerant of this latter mode of ventilation. Moreover, extending the use of Bilevel-auto to those OSA patients not responsive to CPAP, we showed a significantly better correction of nocturnal respiratory disturbances. © 2015 American Academy of Sleep Medicine.

  19. [Possibilities of bi-level positive pressure ventilation in chronic hypoventilation].

    Science.gov (United States)

    Saaresranta, Tarja; Anttalainen, Ulla; Polo, Olli

    2011-01-01

    During the last decade, noninvasive bi-level positive pressure ventilation has enabled respiratory support in inpatient wards and at home. In many cases, a bi-level airway pressure ventilator can be used to avoid artificial airway and respirator therapy, and may shorten hospital stay and save costs. The treatment alleviates the patient's dyspnea and fatigue, whereby the quality of life improves, and in certain situations also the life span increases. The implementation of bi-level positive pressure ventilation by the physician requires knowledge of the basics of respiratory physiology and familiarization with the bi-level airway pressure ventilator.

  20. Use of Respiratory Support in the Biphase Ventilation Airway Mode in the Newborn

    OpenAIRE

    S. N. Koval; A. Ye. Kulagin

    2006-01-01

    Biphasic positive airway pressure (BIPAP) (also known as DuoPAP, BiLevel, BiVent, PCV+, SPAP) is a mode of ventilation with cycling variations between two continuous positive airway pressure levels. It is a mixture of pressure controlled ventilation and spontaneous breathing, which is unrestricted in each phase of the respiratory cycle. The volume displacement caused by the difference between Phigh and Plow airway pressure level. The phase time ratio (PTR — the BIPAP frequency) is calculated ...

  1. Curative effect of continuous positive airway pressure on treatment of patients with obstructive sleep apnea hypopnea syndrome and hypertension: A Meta-analysis

    Directory of Open Access Journals (Sweden)

    Bi-fang MIAO

    2016-12-01

    Full Text Available Objective  To systematically evaluate the curative effect of continuous positive airway pressure (CPAP on treatment of patients with obstructive sleep apnea hypopnea syndrome (OSAHS and hypertension. Methods  The data were retrieved of randomized controlled trials (RCTs about the curative effect of CPAP on treatment of patients with OSAHS and hypertension from PubMed, Cochrane Library, CNKI, VIP, CBM and WanFang database from inception to Oct. 2015. Literature screening, data extraction and risk bias assessment were performed by two independent reviewers, and meta-analysis was then carried out by using RevMan 5.3 software. Results  A total of 16 RCTs involving 2101 patients were included. Meta-analysis revealed that, compared with the antihypertensive drug therapy alone, CPAP plus antihypertensive drug therapy significantly reduced the daytime systolic pressure [MD=–12.60, 95%CI(–17.68 to –7.52, P<0.00001], nighttime systolic pressure [MD=–21.90, 95%CI(–25.94 to –17.86, P<0.00001] and nighttime diastolic pressure [MD=–11.90, 95%CI(–15.44 to –8.36, P<0.00001], while created no significant difference in daytime diastolic pressure, 24-h mean systolic pressure and 24-h mean diastolic pressure in a following-up less than 12 weeks. Whereas in the following-up no less than 12 weeks, compared with the antihypertensive drug therapy alone, CPAP plus antihypertensive drug therapy significantly reduced the 24-h mean systolic pressure [MD=–7.88, 95%CI(–12.09 to –3.66, P=0.00002], 24-h mean diastolic pressure [MD=–5.14, 95%CI(–6.00 to –4.28, P<0.00001], daytime systolic pressure [MD=–5.89, 95%CI(–8.79 to –2.98, P<0.0001], daytime diastolic pressure [MD=–4.34, 95%CI(–6.32 to –2.36, P<0.0001]; nighttime systolic pressure [MD=–7.06, 95%CI(–11.12 to –2.99, P=0.0007] and nighttime diastolic pressure [MD=–4.49, 95%CI (–7.39 to –1.58, P=0.006]. Conclusions  The current evidences suggest that on the basis

  2. Determination of new prediction formula for nasal continuous positive airway pressure in Turkish patients with obstructive sleep apnea syndrome.

    Science.gov (United States)

    Basoglu, Ozen K; Tasbakan, Mehmet Sezai

    2012-12-01

    Race/ethnicity may play an important role in determining body size, severity of obstructive sleep apnea syndrome (OSAS), and effective continuous positive airway pressure (CPAP) (Peff). Turkey is composed of different ethnic groups. Therefore, the aims of this study were to determine new prediction formula for CPAP (Ppred) in Turkish OSAS patients, validate performance of this formula, and compare with Caucasian and Asian formulas. Peff of 250 newly diagnosed moderate-to-severe OSAS patients were calculated by in-laboratory manual titration. Correlation and multiple linear regression analysis were used to model effects of ten anthropometric and polysomnographic variables such as neck circumference (NC) and oxygen desaturation index (ODI) on Peff. New formula was validated in different 130 OSAS patients and compared with previous formulas. The final prediction formula was [Formula: see text]. When Peff of control group was assessed, it was observed that mean Peff was 8.39 ± 2.00 cmH(2)O and Ppred was 8.23 ± 1.22 cmH(2)O. Ppred was within ±3 cmH(2)O of Peff in 96.2% patients. Besides, Peff was significantly correlated with new formula, and prediction formulas developed for Caucasian and Asian populations (r = 0.651, p < 0.001, r = 0.648, p < 0.001, and r = 0.622, p < 0.001, respectively). It is shown that level of CPAP can be successfully predicted from our prediction formula, using NC and ODI and validated in Turkish OSAS patients. New equation correlates with other formulas developed for Caucasian and Asian populations. Our simple formula including ODI, marker of intermittent hypoxia, may be used easily in different populations.

  3. Retrospective, nonrandomized controlled study on autoadjusting, dual-pressure positive airway pressure therapy for a consecutive series of complex insomnia disorder patients

    Directory of Open Access Journals (Sweden)

    Krakow B

    2017-03-01

    Full Text Available Barry Krakow,1–3 Natalia D McIver,1,2 Victor A Ulibarri,1,2 Michael R Nadorff4,5 1Sleep & Human Health Institute, 2Maimonides Sleep Arts & Sciences, Ltd, Albuquerque, 3Los Alamos Medical Center, Los Alamos, NM, 4Department of Psychology, Mississippi State University, Mississippi, MS, 5Department of Psychiatry and Behavioral Sciences, Baylor College of Medicine, Houston, TX, USA Purpose: Emerging evidence shows that positive airway pressure (PAP treatment of obstructive sleep apnea (OSA and upper airway resistance syndrome (UARS in chronic insomnia patients (proposed “complex insomnia” disorder leads to substantial decreases in insomnia severity. Although continuous PAP (CPAP is the pressure mode most widely researched, intolerance to fixed pressurized air is rarely investigated or described in comorbidity patients. This retrospective study examined dual pressure, autoadjusting PAP modes in chronic, complex insomnia disorder patients.Patients and methods: Chronic insomnia disorder patients (mean [SD] insomnia severity index [ISI] =19.11 [3.34] objectively diagnosed with OSA or UARS and using either autobilevel PAP device or adaptive servoventilation (ASV device after failing CPAP therapy (frequently due to intolerance to pressurized air, poor outcomes, or emergence of CSA were divided into PAP users (≥20 h/wk and partial users (<20 h/wk for comparison. Subjective and objective baseline and follow-up measures were analyzed.Results: Of the 302 complex insomnia patients, PAP users (n=246 averaged 6.10 (1.78 nightly hours and 42.71 (12.48 weekly hours and partial users (n=56 averaged 1.67 (0.76 nightly hours and 11.70 (5.31 weekly hours. For mean (SD decreases in total ISI scores, a significant (group × time interaction was observed (F[1,300]=13.566; P<0.0001 with PAP users (–7.59 [5.92]; d=1.63 showing superior results to partial users (-4.34 [6.13]; d=0.81. Anecdotally, patients reported better tolerability with advanced PAP

  4. Erectile Dysfunction and Sexual Hormone Levels in Men With Obstructive Sleep Apnea: Efficacy of Continuous Positive Airway Pressure.

    Science.gov (United States)

    Zhang, Xiao-Bin; Lin, Qi-Chang; Zeng, Hui-Qing; Jiang, Xing-Tang; Chen, Bo; Chen, Xiao

    2016-01-01

    In this study, the prevalence of erectile dysfunction (ED) and serum sexual hormone levels were evaluated in men with obstructive sleep apnea (OSA). In these patients, the efficacy of continuous positive airway pressure (CPAP) was determined. The 207 men (mean age 44.0 ± 11.1 years) enrolled in the study were stratified within four groups based on their apnea-hypopnea index score: simple snoring (n = 32), mild OSA (n = 29), moderate OSA (n = 38), and severe OSA (n = 108). The International Index of Erectile Dysfunction-5 (IIEF-5) score was obtained from each patient, and blood samples for the analysis of sexual hormones (prolactin, luteotropin, follicle-stimulating hormone, estradiol, progestin, and testosterone) were drawn in the morning after polysomnography. The IIEF-5 test and serum sexual hormone measurements were repeated after 3 months of CPAP treatment in 53 men with severe OSA. The prevalence of ED was 60.6 % in OSA patients overall and 72.2 % in those with severe OSA. Compared with the simple snoring group, patients with severe OSA had significantly lower testosterone levels (14.06 ± 5.62 vs. 17.02 ± 4.68, p = .018) and lower IIEF-5 scores (16.33 ± 6.50 vs. 24.09 ± 1.94, p = .001). The differences in the other sexual hormones between groups were not significant. After 3 months of CPAP treatment, there were no significant changes in sexual hormone levels, but the IIEF-5 score had improved significantly (18.21 ± 4.05 vs. 19.21 ± 3.86, p = .001). Severe OSA patients have low testosterone concentration and high ED prevalence. IIEF-5 scores increased significantly after CPAP treatment, but there was no effect on serum testosterone levels.

  5. Early nasal continuous positive airway pressure versus INSURE in VLBW neonates

    Directory of Open Access Journals (Sweden)

    Ana Saianda

    2010-09-01

    Full Text Available Background: Evidence suggests the INSURE strategy (INtubate-SURfactant administration and Extubate to nasal continuous positive airway pressure [nCPAP] is superior to mechanical ventilation (MV with rescue surfactant for the management of respiratory distress syndrome (RDS in very low birth weight (VLBW neonates. There is limited data, however, to assess whether INSURE is superior to nCPAP alone. We aimed to compare these two strategies regarding early and late outcomes. Methods: Retrospective cohort study from Jan/2002 to Aug/2008. We included VLBW neonateswith gestational age (GA ≤ 30 weeks registered in the Vermont Oxford Network that used either nCPAP alone (nCPAP group, N = 40, or with INSURE (INSURE group, N = 56. We assessed early (RDS, need for rescue surfactant, and CPAP failure with MV and late outcomes (chronic lung disease of prematurity (CLD, mortality, and composite outcome of mortality and/or CLD. Results: Neonates in the INSURE group had lower mean GA, while other baseline variables were comparable. The proportion of RDS was significantly superior in the nCPAP group (53% vs. 30%; adjusted OR [95% CI] – 0.2 [0.1-0.6]. Therapeutic surfactant was administered to all cases with RDS in the nCPAP group, but to none from the INSURE group. MV was more frequently required in the nCPAP group (11/ 40, 28% vs. 9/ 56, 12%; p = 0.04. No statistically significant differences were found in either of the late outcomes. Conclusion: The use of nCPAP alone in VLBW neonates with GA ≤ 30 weeks may be associated with slightly poorer early outcomes than the INSURE strategy, but there were no significant differences in CLD or mortality. Resumo: Introdução: Pretende-se determinar se a utilização do método INSURE em recém-nascidos de muito baixo peso, com idade gestacional (IG ≤ 30 semanas se associa a menor morbilidade e mortalidade quando comparado com uso de nCPAP isolado. Métodos: Estudo de

  6. Positive airway pressure adherence and subthreshold adherence in posttraumatic stress disorder patients with comorbid sleep apnea

    Directory of Open Access Journals (Sweden)

    Krakow BJ

    2017-11-01

    Full Text Available Barry J Krakow,1–3 Jessica J Obando,2 Victor A Ulibarri,1,2 Natalia D McIver1,2 1Sleep & Human Health Institute, 2Maimonides Sleep Arts & Sciences, Albuquerque, 3Los Alamos Medical Center, Los Alamos, NM, USA Study objectives: Patients with comorbid posttraumatic stress disorder (PTSD and obstructive sleep apnea (OSA manifest low adherence to continuous positive airway pressure (CPAP due to fixed, pressure-induced expiratory pressure intolerance (EPI, a subjective symptom and objective sign aggravated by anxiety sensitivity and somatosensory amplification. As advanced PAP therapy modes (ie, auto-bilevel PAP [ABPAP] or adaptive servo-ventilation [ASV] may address these side effects, we hypothesized such treatment would be associated with decreased expiratory intolerance and increased adherence in posttraumatic stress patients with co-occurring OSA.Methods: We reviewed charts of 147 consecutive adult patients with moderately severe posttraumatic stress symptoms and objectively diagnosed OSA. All patients failed or rejected CPAP and were manually titrated on auto-adjusting, dual-pressure ABPAP or ASV modes in the sleep laboratory, a technique to eliminate flow limitation breathing events while resolving EPI. Patients were then prescribed either mode of therapy. Follow-up encounters assessed patient use, and objective data downloads (ODDs measured adherence.Results: Of 147 charts reviewed, 130 patients were deemed current PAP users, and 102 provided ODDs: 64 used ASV and 38 used ABPAP. ODDs yielded three groups: 59 adherent per insurance conventions, 19 subthreshold compliant partial users, and 24 noncompliant. Compliance based on available downloads was 58%, notably higher than recently reported rates in PTSD patients with OSA. Among the 19 partial users, 17 patients were minutes of PAP use or small percentages of nights removed from meeting insurance compliance criteria for PAP devices.Conclusion: Research is warranted on advanced PAP modes in

  7. A real-world comparison of apnea-hypopnea indices of positive airway pressure device and polysomnography.

    Directory of Open Access Journals (Sweden)

    Ritwick Agrawal

    Full Text Available The apnea hypopnea index (AHI reported by positive airway pressure (PAP device is widely used in clinical practice, yet its correlation with standardized AHI obtained during the sleep study is not established. The current study was conducted to investigate the correlation between AHI estimated by the PAP device and reported on the smart card with the AHI found during the PAP polysomnography (PSG in the "real world" setting at an academic sleep center. We retrospectively reviewed the medical records of 280 patients who underwent a PAP titration PSG at Drexel sleep center, and were later prescribed a PAP device. The AHI was categorized in clinically relevant subgroups (as AHI ≤5 and AHI >5. The AHI at the final pressure on the PSG and the average AHI from the prescribed PAP device were compared. The results showed that in the majority (77.3% of patients (126 of 163, the AHI from both PAP device and PSG correlated well and were in the same category (AHI ≤5 and AHI >5 respectively. The majority of patients (80.7% with PSG AHI of 5, 61.5% patients reported good control, with AHI <5 on PAP device AHI. We conclude that in a majority of patients who were optimally titrated in the sleep laboratory, the PAP device continued to show optimal control at home.

  8. Efficiency of Continuous Positive Airway Pressure or High-Frequency Jet Ventilation by Means a Nasooral Mask in the Treatment of Pulmonary Edema

    Directory of Open Access Journals (Sweden)

    J. Salantay

    2008-01-01

    Full Text Available Objective: to compare the efficiency of continuous positive airway pressure (CPAP and high-frequency jet ventilation by means of a mask (HFJV-M in the treatment of cardiogenic edema of the lung. Design: a retrospective study. Setting: Department of Anesthesiology and Intensive Medicine, Hospital NsP, Vranov, Slovakia. Subjects and methods. A hundred and ninety-six patients with varying cardiogenic edema of the lung were divided into 3 groups according to the severity of pulmonary edema (PE. By taking into account comparable pharmacotherapy, mean airway pressure, and FiO2, the authors compared the efficiency of CPAP (n=64 and HFJV-M (n=101 from the rate of changes in respiration rate, blood oxygenation, acid-base balance, and the duration of ventilation support and the length of stay in the intensive care unit (ICU. The results were assessed by the unpaired Student’s test. The procedure of artificial ventilation via HFJV-M was approved by the Professional and Ethics Committee, Ministry of Health in the Republic of Slovakia, in 1989 for clinical application. Results. Comparison of CPAP or HFJV-M used in mild PE that was called Phase 1 of PE revealed no statistically significant differences in the parameters being assessed. In severer forms of PE characterized as Phases 2 and 3, the use of HFJV-M in the first 3 hours of ventilation maintenance caused a rapider reduction in spontaneous respiration rate from 25—33 per min to 18—22 per min (p>0.01. The application of HFJV-M also showed a statistically significant difference in the correction rate of PaO2, pH, and oxygenation index (PaO2/FIO2 (p>0.01 predominantly within the first 2 hours of therapy. Comparison of the mean duration of necessary ventilation maintenance (CPAP versus HFJV-M: 10.9 versus 6.8 hours and the mean length of stay in the ICU (CPAP versus HFJV-N: 2.7 versus 2 days revealed a statistically significant difference (p>0.01 and p>0.05, respectively. Only 6.6% of the HFJV-M group

  9. Elevated levels of endothelial cell-derived microparticles following short-term withdrawal of continuous positive airway pressure in patients with obstructive sleep apnea: data from a randomized controlled trial.

    Science.gov (United States)

    Ayers, Lisa; Stoewhas, Anne-Christin; Ferry, Berne; Stradling, John; Kohler, Malcolm

    2013-01-01

    Obstructive sleep apnea has been associated with impaired endothelial function; however, the mechanisms underlying this association are not completely understood. Cell-derived microparticles may provide a link between obstructive sleep apnea and endothelial dysfunction. This randomized controlled trial aimed to examine the effect of a 2-week withdrawal of continuous positive airway pressure (CPAP) therapy on levels of circulating microparticles. Forty-one obstructive sleep apnea patients established on CPAP treatment were randomized to either CPAP withdrawal (subtherapeutic CPAP) or continuing therapeutic CPAP, for 2 weeks. Polysomnography was performed and circulating levels of microparticles were analyzed by flow cytometry at baseline and 2 weeks. CPAP withdrawal led to a recurrence of obstructive sleep apnea. Levels of CD62E+ endothelium-derived microparticles increased significantly in the CPAP withdrawal group compared to the continuing therapeutic CPAP group (median difference in change +32.4 per µl; 95% CI +7.3 to +64.1 per µl, p = 0.010). CPAP withdrawal was not associated with a statistically significant increase in granulocyte, leukocyte, and platelet-derived microparticles when compared with therapeutic CPAP. Short-term withdrawal of CPAP therapy leads to a significant increase in endothelium-derived microparticles, suggesting that microparticle formation may be causally linked to obstructive sleep apnea and may promote endothelial activation. Copyright © 2012 S. Karger AG, Basel.

  10. Sleep apnea-related risk of motor vehicle accidents is reduced by continuous positive airway pressure: Swedish Traffic Accident Registry data.

    Science.gov (United States)

    Karimi, Mahssa; Hedner, Jan; Häbel, Henrike; Nerman, Olle; Grote, Ludger

    2015-03-01

    Obstructive sleep apnea (OSA) is associated with an increased risk of motor vehicle accidents (MVAs). The rate of MVAs in patients suspected of having OSA was determined and the effect of continuous positive airway pressure (CPAP) was investigated. MVA rate in patients referred for OSA was compared to the rate in the general population using data from the Swedish Traffic Accident Registry (STRADA), stratified for age and calendar year. The risk factors for MVAs, using demographic and polygraphy data, and MVA rate before and after CPAP were evaluated in the patient group. Clinical sleep laboratory and population based control (n = 635,786). There were 1,478 patients, male sex 70.4%, mean age 53.6 (12.8) y. CPAP. The number of accidents (n = 74) among patients was compared with the expected number (n = 30) from a control population (STRADA). An increased MVA risk ratio of 2.45 was found among patients compared with controls (P accident risk was most prominent in the elderly patients (65-80 y, seven versus two MVAs). In patients, driving distance (km/y), EDS (Epworth Sleepiness score ≥ 16), short habitual sleep time (≤5 h/night), and use of hypnotics were associated with increased MVA risk (odds ratios 1.2, 2.1, 2.7 and 2.1, all P ≤ 0.03). CPAP use ≥ 4 h/night was associated with a reduction of MVA incidence (7.6 to 2.5 accidents/1,000 drivers/y). The MVA risk in this large cohort of unselected patients with OSA suggests a need for accurate tools to identify individuals at risk. Sleep apnea severity (e.g., apnea-hypopnea index) failed to identify patients at risk. © 2015 Associated Professional Sleep Societies, LLC.

  11. Influence of marital status and employment status on long-term adherence with continuous positive airway pressure in sleep apnea patients.

    Science.gov (United States)

    Gagnadoux, Frédéric; Le Vaillant, Marc; Goupil, François; Pigeanne, Thierry; Chollet, Sylvaine; Masson, Philippe; Humeau, Marie-Pierre; Bizieux-Thaminy, Acya; Meslier, Nicole

    2011-01-01

    Long-term adherence is a major issue in patients receiving home continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea-hypopnea syndrome (OSAHS). In a multicenter prospective cohort (the Institut de Recherche en Santé Respiratoire des Pays de la Loire [IRSR] sleep cohort) of consecutive OSAHS patients in whom CPAP had been prescribed for at least 90 days, we studied the impact on long-term treatment adherence of socioeconomic factors, patients and disease characteristics prior to CPAP initiation. Among 1,141 patients in whom CPAP had been prescribed for an average of 504±251 days (range: 91 to 1035), 674 (59%) were adherent with a mean daily use of CPAP≥4 h (mean: 6.42±1.35 h). Stepwise regression analysis identified 4 independent factors of CPAP adherence including apnea-hypopnea index (AHI) (OR: 1.549, 95%CI 1.163 to 2.062 for AHI≥30 vs. AHIstatus (OR: 1.414, 95%CI 1.097-1.821 for retired vs. employed; p = 0.007) and marital status (OR: 1.482, 95%CI 1.088-2.019 for married or living as a couple vs. living alone; p = 0.01). Age, gender, Epworth sleepiness scale, depressive syndrome, associated cardiovascular morbidities, educational attainment and occupation category did not influence CPAP adherence. Marital status and employment status are independent factors of CPAP adherence in addition to BMI and disease severity. Patients living alone and/or working patients are at greater risk of non-adherence, whereas adherence is higher in married and retired patients. These findings suggest that the social context of daily life should be taken into account in risk screening for CPAP non-adherence. Future interventional studies targeting at-risk patients should be designed to address social motivating factors and work-related barriers to CPAP adherence.

  12. Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

    Energy Technology Data Exchange (ETDEWEB)

    Goldstein, Jeffrey D. [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Lawrence, Yaacov R. [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Appel, Sarit; Landau, Efrat; Ben-David, Merav A.; Rabin, Tatiana; Benayun, Maoz; Dubinski, Sergey; Weizman, Noam; Alezra, Dror; Gnessin, Hila; Goldstein, Adam M.; Baidun, Khader [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Segel, Michael J.; Peled, Nir [Department of Pulmonary Medicine, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel); Symon, Zvi, E-mail: symonz@sheba.health.gov.il [Department of Radiation Oncology, Chaim Sheba Medical Center, Tel Hashomer, Tel Aviv (Israel); Sackler School of Medicine, Tel Aviv University, Tel Aviv (Israel)

    2015-10-01

    Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm{sup 3} and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy.

  13. Continuous Positive Airway Pressure for Motion Management in Stereotactic Body Radiation Therapy to the Lung: A Controlled Pilot Study

    International Nuclear Information System (INIS)

    Goldstein, Jeffrey D.; Lawrence, Yaacov R.; Appel, Sarit; Landau, Efrat; Ben-David, Merav A.; Rabin, Tatiana; Benayun, Maoz; Dubinski, Sergey; Weizman, Noam; Alezra, Dror; Gnessin, Hila; Goldstein, Adam M.; Baidun, Khader; Segel, Michael J.; Peled, Nir; Symon, Zvi

    2015-01-01

    Objective: To determine the effect of continuous positive airway pressure (CPAP) on tumor motion, lung volume, and dose to critical organs in patients receiving stereotactic body radiation therapy (SBRT) for lung tumors. Methods and Materials: After institutional review board approval in December 2013, patients with primary or secondary lung tumors referred for SBRT underwent 4-dimensional computed tomographic simulation twice: with free breathing and with CPAP. Tumor excursion was calculated by subtracting the vector of the greatest dimension of the gross tumor volume (GTV) from the internal target volume (ITV). Volumetric and dosimetric determinations were compared with the Wilcoxon signed-rank test. CPAP was used during treatment if judged beneficial. Results: CPAP was tolerated well in 10 of the 11 patients enrolled. Ten patients with 18 lesions were evaluated. The use of CPAP decreased tumor excursion by 0.5 ± 0.8 cm, 0.4 ± 0.7 cm, and 0.6 ± 0.8 cm in the superior–inferior, right–left, and anterior–posterior planes, respectively (P≤.02). Relative to free breathing, the mean ITV reduction was 27% (95% confidence interval [CI] 16%-39%, P<.001). CPAP significantly augmented lung volume, with a mean absolute increase of 915 ± 432 cm 3 and a relative increase of 32% (95% CI 21%-42%, P=.003), contributing to a 22% relative reduction (95% CI 13%-32%, P=.001) in mean lung dose. The use of CPAP was also associated with a relative reduction in mean heart dose by 29% (95% CI 23%-36%, P=.001). Conclusion: In this pilot study, CPAP significantly reduced lung tumor motion compared with free breathing. The smaller ITV, the planning target volume (PTV), and the increase in total lung volume associated with CPAP contributed to a reduction in lung and heart dose. CPAP was well tolerated, reproducible, and simple to implement in the treatment room and should be evaluated further as a novel strategy for motion management in radiation therapy

  14. Experimental intra-abdominal hypertension influences airway pressure limits for lung protective mechanical ventilation.

    Science.gov (United States)

    Cortes-Puentes, Gustavo A; Cortes-Puentes, Luis A; Adams, Alexander B; Anderson, Christopher P; Marini, John J; Dries, David J

    2013-06-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) may complicate monitoring of pulmonary mechanics owing to their impact on the respiratory system. However, recommendations for mechanical ventilation of patients with IAH/ACS and the interpretation of thoracoabdominal interactions remain unclear. Our study aimed to characterize the influence of elevated intra-abdominal pressure (IAP) and positive end-expiratory pressure (PEEP) on airway plateau pressure (PPLAT) and bladder pressure (PBLAD). Nine deeply anesthetized swine were mechanically ventilated via tracheostomy: volume-controlled mode at tidal volume (VT) of 10 mL/kg, frequency of 15, inspiratory-expiratory ratio of 1:2, and PEEP of 1 and 10 cm H2O (PEEP1 and PEEP10, respectively). A tracheostomy tube was placed in the peritoneal cavity, and IAP levels of 5, 10, 15, 20, and 25 mm Hg were applied, using a continuous positive airway pressure system. At each IAP level, PBLAD and airway pressure measurements were performed during both PEEP1 and PEEP10. PBLAD increased as experimental IAP rose (y = 0.83x + 0.5; R = 0.98; p < 0.001 at PEEP1). Minimal underestimation of IAP by PBLAD was observed (-2.5 ± 0.8 mm Hg at an IAP of 10-25 mm Hg). Applying PEEP10 did not significantly affect the correlation between experimental IAP and PBLAD. Approximately 50% of the PBLAD (in cm H2O) was reflected by changes in PPLAT, regardless of the PEEP level applied. Increasing IAP did not influence hemodynamics at any level of IAP generated. With minimal underestimation, PBLAD measurements closely correlated with experimentally regulated IAP, independent of the PEEP level applied. For each PEEP level applied, a constant proportion (approximately 50%) of measured PBLAD (in cm H2O) was reflected in PPLAT. A higher safety threshold for PPLAT should be considered in the setting of IAH/ACS as the clinician considers changes in VT. A strategy of reducing VT to cap PPLAT at widely recommended values may not be

  15. Bubble vs conventional continuous positive airway pressure for prevention of extubation failure in preterm very low birth weight infants: a pilot study.

    Science.gov (United States)

    Yadav, Sucheta; Thukral, Anu; Sankar, M Jeeva; Sreenivas, V; Deorari, Ashok K; Paul, Vinod K; Agarwal, Ramesh

    2012-09-01

    To compare the efficacy of bubble and conventional nasal continuous positive airway pressure (CPAP) in preventing extubation failure (EF) in preterm infants. Infants of gestation ≤32 wk and birth weight <1500 g, ready for initial extubation within first wk of life were randomly allocated to either bubble (n = 16) or conventional (n = 16) CPAP. A standardized protocol was used for extubation. Bubble CPAP was delivered by Fischer and Paykel equipment using short binasal prongs and conventional CPAP was delivered by a ventilator using Argyle short binasal prongs. CPAP was initiated at a pressure of 4-6 cm of H(2)O and FiO(2) of 0.4-0.5 and adjusted to maintain normal saturation (90-93%) and comfortable breathing. Primary outcome was EF, defined as need for mechanical ventilation within 72 h of extubation. Baseline characteristics including birth weight (g; 1027 ± 243 vs. 1018 ± 227; p = 0.83), gestation (wk; 28.7 ± 1.8 vs. 28.4 ± 1.6; p = 0.30), infants <28 wk gestation (6 vs. 7, p = 0.72) were comparable between the two groups. Respiratory distress syndrome was the indication for ventilation in 13 (81%) and 14 (87%) infants on bubble CPAP and conventional CPAP groups respectively. (p = 0.99). There was no difference in the EF rates between the bubble (n = 4) and conventional CPAP (n = 9) groups. (RR 0.49; 95% CI 0.20-1.2; p = 0.14). Median time to extubation failure was also comparable between the two groups (h; median [range]: 29 [14-49] vs. 17 [7-28]; p = 0.35). The possibility that bubble CPAP may be associated with reduced EF as suggested in this pilot study requires further investigation in an adequately powered multicentric study.

  16. 21 CFR 868.1780 - Inspiratory airway pressure meter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Inspiratory airway pressure meter. 868.1780 Section 868.1780 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... meter. (a) Identification. An inspiratory airway pressure meter is a device used to measure the amount...

  17. Effect of continuous positive airway pressure treatment on short-term memory performance over 24 h of sustained wakefulness in patients with obstructive sleep apnea-hypopnea syndrome.

    Science.gov (United States)

    Grenèche, Jérôme; Krieger, Jean; Bertrand, Frédéric; Erhardt, Christine; Maumy, Myriam; Tassi, Patricia

    2013-10-01

    Few studies have examined the impact of continuous positive airway pressure (CPAP) therapy on short-term memory (STM) over sustained wakefulness in patients with obstructive sleep apnea-hypopnea syndrome (OSAHS). We have investigated if impaired STM can be reversed by CPAP treatment in a 24-h sustained wakefulness paradigm. Our follow-up study was conducted with repeated-memory tasks within 12 OSAHS patients and 10 healthy controls who underwent three 32-h sessions, one before CPAP (T0) and the second (T3) and the third (T6), after 3 and 6 months of treatment, respectively, for OSAHS patients. Each session included one night of sleep followed by 24h of sustained wakefulness, during which both groups performed STM tasks including both digit span (DS) and Sternberg tasks. Untreated OSAHS patients had no deficit in the forward DS task measuring immediate memory but were impaired in STM, especially working memory assessed by the complex Sternberg task and the backward DS. However, only performance in the latter was improved after 6 months of CPAP treatment. Because the high level of memory scanning required high speed in information processing, persistent impairment on the complex Sternberg task may be attributable to working memory slowing, possibly enhanced by sustained wakefulness. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  18. Impact of Prophylactic Continuous Positive Airway Pressure on Transient Tachypnea of the Newborn and Neonatal Intensive Care Admission in Newborns Delivered by Elective Cesarean Section.

    Science.gov (United States)

    Celebi, Miray Yilmaz; Alan, Serdar; Kahvecioglu, Dilek; Cakir, Ufuk; Yildiz, Duran; Erdeve, Omer; Arsan, Saadet; Atasay, Begum

    2016-01-01

    This study aims to evaluate the effect of the prophylactic continuous positive airway pressure (CPAP) administration in the delivery room to newborns who were delivered by elective cesarean section (CS). Inborn infants with gestational age between 34(0/7) to 38(6/7) and born by elective CS were prospectively randomized to receive either prophylactic CPAP for 20 minutes via face mask or standardized care without CPAP in the delivery room. Primary outcomes were the incidence of transient tachypnea of the newborn (TTN) and neonatal intensive care unit (NICU) admission due to respiratory distress. A total of 259 infants with a mean gestational age of 37.7 ± 0.8 weeks and birth weight of 3,244 ± 477 g were included. A total of 134 infants received prophylactic CPAP and 125 received control standard care. The rate of NICU admission was significantly lower in prophylactic CPAP group (p = 0.045). Although the rate of TTN was lower in the prophylactic CPAP group, the difference was not statistically significant (p = 0.059). The rate of NICU admission due to respiratory distress was significantly higher in late-preterm cohort than early-term cohort (p CPAP administration decreases the rate of NICU admission without any side effect in late-preterm and early-term infants delivered by elective CS. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Wire-guided (Seldinger technique intubation through a face mask in urgent, difficult and grossly distorted airways

    Directory of Open Access Journals (Sweden)

    Jake M Heier

    2012-01-01

    Full Text Available We report two cases of successful urgent intubation using a Seldinger technique for airway management through an anesthesia facemask, while maintaining ventilation in patients with difficult airways and grossly distorted airway anatomy. In both cases, conventional airway management techniques were predicted to be difficult or impossible, and a high likelihood for a surgical airway was present. This technique was chosen as it allows tracheal tube placement through the nares during spontaneous ventilation with the airway stented open and oxygen delivery with either continuous positive airway pressure and/or pressure support ventilation. This unhurried technique may allow intubation when other techniques are unsuitable, while maintaining control of the airway.

  20. Effects of condensate in the exhalation limb of neonatal circuits on airway pressure during bubble CPAP.

    Science.gov (United States)

    Youngquist, Tiffany M; Richardson, C Peter; Diblasi, Robert M

    2013-11-01

    Bubble CPAP is frequently used in spontaneously breathing infants with lung disease. Often bubble CPAP systems lack pressure alarms and pressure-release valves. We observed a large volume of condensate in the exhalation limb of a patient circuit and conducted a series of experiments to test the hypothesis that accumulated condensate could affect delivered pressures. An anatomically accurate nasal airway model of a preterm infant was attached to a spontaneously breathing lung model. A bubble CPAP system was attached to the nasal airway with bi-nasal short prongs, and the rate of fluid condensation was measured. Next, tracheal pressures were monitored digitally to detect changes in airway pressure related to condensate accumulation. Measurements were obtained with volumes of 0, 5, 10, 15, and 20 mL of water in the exhalation limb, at flows of 4, 6, 8, and 10 L/min. Measurements with 20 mL in the exhalation limb were recorded with and without a pressure-relief valve in the circuit. The rate of condensate accumulation was 3.8 mL/h. At volumes of ≥ 10 mL, noticeable alterations in the airway pressure waveforms and significant increases in mean tracheal pressure were observed. The pressure-relief valve effectively attenuated peak tracheal pressure, but only decreased mean pressure by 0.5-1.5 cm H2O. Condensate in the exhalation limb of the patient circuit during bubble CPAP can significantly increase pressure delivered to the patient. The back and forth movement of this fluid causes oscillations in airway pressure that are much greater than the oscillations created by gas bubbling out the exhalation tube into the water bath. We recommend continuously monitoring pressure at the nasal airway interface, placing an adjustable pressure-relief valve in the circuit, set to 5 cm H2O above the desired mean pressure, and emptying fluid from the exhalation limb every 2-3 hours.

  1. Cerebral hemodynamics in patients with obstructive sleep apnea syndrome monitored with near-infrared spectroscopy (NIRS) during positive airways pressure (CPAP) therapy: a pilot study

    Science.gov (United States)

    Zhang, Zhongxing; Schneider, Maja; Laures, Marco; Fritschi, Ursula; Lehner, Isabella; Qi, Ming; Khatami, Ramin

    2014-03-01

    In obstructive sleep apnea syndrome (OSA) the periodic reduction or cessation of breathing due to narrowing or occlusion of the upper airway during sleep leads to daytime symptoms and increased cardiovascular risk, including stroke. The higher risk of stroke is related to the impairment in cerebral vascular autoregulation. Continuous positive airways pressure (CPAP) therapy at night is the most effective treatment for OSA. However, there is no suitable bedside monitoring method evaluating the treatment efficacy of CPAP therapy, especially to monitor the recovery of cerebral hemodynamics. NIRS is ideally suited for non-invasive monitoring the cerebral hemodynamics during sleep. In this study, we will for first time assess dynamic changes of cerebral hemodynamics during nocturnal CPAP therapy in 3 patients with OSA using NIRS. We found periodic oscillations in HbO2, HHb, tissue oxygenation index (TOI) and blood volume associated with periodic apnea events without CPAP in all OSA patients. These oscillations were gradually attenuated and finally eliminated with the stepwise increments of CPAP pressures. The oscillations were totally eliminated in blood volume earlier than in other hemodynamic parameters. These results suggested that 1) the cerebral hemodynamic oscillations induced by OSA events can effectively be attenuated by CPAP therapy, and 2) blood flow and blood volume recovered first during CPAP therapy, followed by the recovery of oxygen consumption. Our study suggested that NIRS is a useful tool to evaluate the efficacy of CPAP therapy in patients with OSA bedside and in real time.

  2. Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study

    Directory of Open Access Journals (Sweden)

    Harihar Vishwanath Hegde

    2018-01-01

    Full Text Available Background and Aims: Airway used in prone position should be efficacious and safe. The Streamlined Liner of the Pharynx Airway (SLIPA™ and Laryngeal Mask Airway-ProSeal (PLMA provide better airway seal and protection against aspiration. We planned to evaluate the performance of SLIPA™, PLMA and endotracheal tube (ETT in prone position. Methods: 114 adult patients undergoing elective surgery in prone position under general anaesthesia were randomised into Group-T (ETT, Group-S (SLIPA™ and Group-P (PLMA. Airways were inserted in supine position and patients turned prone subsequently. Airway characteristics, ventilatory parameters and complications were noted. One-way analysis of variance, Mann–Whitney U-test and Chi-square or Fisher's exact test were used. Results: Tidal volumes, peak airway pressure and compliance were comparable at all times. Leak pressure was significantly higher (P < 0.001 in Group-T (mean leak pressure = 40 cmH2O when compared to Group-S and Group-P at all the times of recording, and there was no significant difference between Group-S and Group-P. The number of patients requiring airway/neck manipulation in prone position was significantly higher (P < 0.001 in Group-S (19 [55.9%] when the three groups were compared (none in Group-T and in comparison with Group-P (5 [14.7%], P < 0.001. On airway removal, the incidence of complications and airway reaction was significantly higher in Group-T. Group-S had a significantly higher incidence of dysphagia at 2 h postoperatively. Conclusion: ETT was most efficacious. SLIPA™ and PLMA were efficacious, safe and less stimulating to the airway during removal. More patients required SLIPA™ airway/neck manipulation.

  3. Initial treatment of respiratory distress syndrome with nasal intermittent mandatory ventilation versus nasal continuous positive airway pressure: A randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Amir-Mohammad Armanian

    2014-01-01

    Full Text Available Background: Neonatal respiratory distress syndrome (RDS in premature infants who survived and its complications are a common problem. Due to high morbidity and mechanical ventilation (MV nowadays researchers in interested minimizing MV. To determine, in very low birth weight (BW preterm neonates with RDS, if initial treatment with nasal intermittent mandatory ventilation (early NIMV compared with early nasal continuous positive airway pressure (early NCPAP obtains more favorable outcomes in terms of the duration of treatment, and the need for endotracheal tube ventilation. Methods: In this single-center randomized control trial study, infants (BW ≤ 1500 g and/or gestational age ≤ 34 weeks with respiratory distress were considered eligible. Forty-four infants were randomly assigned to receive early-NIMV and 54 comparable infants to early-NCPAP. Surfactants were given, when FIO 2 requirement was of >30%. Primary outcomes were failure of noninvasive respiratory support, that is, the need for MV in the first 48 h of life and for the duration of noninvasive respiratory support in each group. Results: 98 infants were enrolled (44 in the NIMV and 54 in the NCPAP group. The Preventive power of MV of NIMV usage (95.5% was not lower than the NCPAP (98.1% strength (hazard ratio: 0.21 (95% confidence interval: 0.02-2.66; P: 0.23. The duration of noninvasive respiratory support in the NIMV group was significantly shorter than NCPAP (the median (range was 24 (18.00-48.00 h versus 48.00 (22.00-120.00 h in NIMV versus NCPAP groups; P < 0.001. Similarly, the duration of dependency on oxygen was less, for NIMV (the median (range was 96.00 (41.00-504.00 h versus144.00 (70.00-1130.00 h in NIMV versus NCPAP groups; P: 0.009. Interestingly, time to full enteral feeds and length of hospital stay were more favorable in the NIMV versus the NCPAP group. Conclusions: Initial treatment of RDS with NIMV was safe, and well tolerated. Furthermore, NIMV had excellent

  4. Efficacy of the addition of positive airway pressure to conventional chest physiotherapy in resolution of pleural effusion after drainage: protocol for a randomised controlled trial.

    Science.gov (United States)

    da Conceição Dos Santos, Elinaldo; Lunardi, Adriana Claudia

    2015-04-01

    Chest drainage for pleural effusion can cause pain and changes in respiratory function. It can also increase the risk of pulmonary complications and impair functional ability, which may increase length of hospital stay and the associated costs. For these reasons, surgical and clinical strategies have been adopted to reduce the duration of chest drainage. To evaluate the efficacy of the addition of intermittent positive airway pressure applied by the Muller reanimator via a rubber facial mask versus conventional physiotherapy on the duration of chest drainage (primary objective), and its effect on the recovery of respiratory function, length of hospital stay and incidence of pulmonary complications (secondary objectives). Randomised, controlled trial. Inpatients with pleural effusion, aged over 18 years, who have had chest drainage in situ for drain will be a transudate output ≤ 200ml over 24hours and full lung expansion on chest radiography, as assessed by a blinded physician. Duration of chest drainage, length of hospital stay, and any pulmonary complications diagnosed during hospitalisation will be recorded. Intention to treat using: survival analysis for duration of chest drainage, and length of hospital stay; analysis of variance for chest-tube output, lung function and peripheral oxygen saturation; and chi-square tests for comparing the incidence of pulmonary complications between groups. Conventional chest physiotherapy and intermittent positive airway pressure breathing are widely indicated for people with pleural effusion and chest drains; however, no studies have evaluated the real benefit of this type of treatment. Our hypothesis is that optimised lung expansion achieved through the application of intermittent positive airway pressure will accelerate the reabsorption of pleural effusion, decrease the duration of chest drainage and respiratory system impairment, reduce the length of hospital stay, and reduce the incidence of pulmonary complications

  5. The Effects of Massage with Coconut and Sunflower Oils on Oxygen Saturation of Premature Infants with Respiratory Distress Syndrome Treated With Nasal Continuous Positive Airway Pressure

    Directory of Open Access Journals (Sweden)

    Sousan Valizadeh

    2012-11-01

    Full Text Available Introduction: Nowadays particular emphasis is placed on the developmental aspects of premature infants care. Massage therapy is one of the best-known methods of caring. Due to the minimal touch policy in neonatal intensive care units (NICUs, massaging is not usually performed on premature infants. However, there is not sufficient evidence to support the claim that newborn infants with complex medical conditions should not be massaged. This study aimed to determine the effects of massage with coconut and sunflower oils on oxygen saturation of infants with respiratory distress syndrome (RDS treated with nasal continuous positive airway pressure (NCPAP. Methods: This was a randomized controlled trial on 90 newborns who were admitted to Alzahra Hospital (Tabriz, Iran. The infants were divided into control and massage therapy groups (massage with coconut and sunflower oils. Data was collected using a hospital documentation form. A 15-minute daily massage was performed for 3 days. Respiratory rate (RR, fraction of inspired oxygen (FiO2 and oxygen saturation were measured 5 minutes before the massage, 3 times during the massage, and 5 minutes after the massage. The collected data was analyzed using a mixed model. Results: In comparison to coconut oil and control groups, mean oxygen saturation of sunflower oil group was improved. In addition, the coconut massage group showed lower oxygen saturation than the control group but was all values were within the normal range. Although massage decreased oxygen saturation, there was no need to increase FiO2. Conclusion: Massage therapy can provide developmental care for infants treated with NCPAP.

  6. Natural history of treatment-emergent central sleep apnea on positive airway pressure: A systematic review.

    Science.gov (United States)

    Nigam, Gaurav; Riaz, Muhammad; Chang, Edward T; Camacho, Macario

    2018-01-01

    Treatment-emergent central sleep apnea (TECSA) is observed in some patients when they are treated with positive airway pressure (PAP) after significant resolution of the preexisting obstructive events in patients with obstructive sleep apnea. The objective of this study was to systematically review the literature for studies describing the natural history of TECSA. PubMed, Medline, Scopus, Web of Science, and Cochran Library databases were searched through June 29, 2017. Five studies were identified that discussed the natural history of TECSA. TECSA developed in 3.5%-19.8% of PAP-treated patients. Treatment-persistent central sleep apnea (TPCSA), representing protracted periods of PAP therapy-related central apneas, was noted in 14.3%-46.2% of patients with TECSA. Delayed-TECSA (D-TECSA) represents an anomalous TECSA entity appearing weeks to months after initial PAP therapy. D-TECSA was observed in 0.7%-4.2% of OSA patients undergoing PAP treatment (after at least 1 month). In patients with TECSA, a higher apnea-hypopnea index (AHI) and central apnea index at their baseline study or a higher residual AHI at their titration study may be associated with an increased likelihood of conversion to TPCSA. Overall, TECSA developed in 3.5%-19.8% of PAP-treated patients with OSA. The vast majority will experience complete resolution of central apneas over a few weeks to months. Unfortunately, about a third of patients with TECSA may continue to exhibit persistence of central sleep apnea on reevaluation. A small proportion may experience D-TECSA after few weeks to several months of initial exposure to PAP therapy.

  7. Short term evaluation of respiratory effort by premature infants supported with bubble nasal continuous airway pressure using Seattle-PAP and a standard bubble device

    Science.gov (United States)

    Welty, Stephen E.; Rusin, Craig G.; Stanberry, Larissa I.; Mandy, George T.; Gest, Alfred L.; Ford, Jeremy M.; Backes, Carl H.; Richardson, C. Peter; Howard, Christopher R.; Hansen, Thomas N.

    2018-01-01

    Background Almost one million prematurely born infants die annually from respiratory insufficiency, predominantly in countries with limited access to respiratory support for neonates. The primary hypothesis tested in the present study was that a modified device for bubble nasal continuous positive airway pressure (Bn-CPAP) would provide lower work of spontaneous breathing, estimated by esophageal pressure-rate products. Methods Infants born CPAP with FiO2 CPAP, then 2 h with Bn-CPAP using a modified bubble device presently termed Seattle-PAP, which produces a different pattern of pressure fluctuations and which provided greater respiratory support in preclinical studies, then 2 h on standard Bn-CPAP. Results All 40 infants enrolled completed the study and follow-up through 36 wks post menstrual age or hospital discharge, whichever came first. No infants were on supplemental oxygen at completion of follow-up. No infants developed pneumothoraces or nasal trauma, and no adverse events attributed to the study were observed. Pressure-rate products on the two devices were not different, but effort of breathing, assessed by areas under esophageal pressure-time curves, was lower with Seattle-PAP than with standard Bn-CPAP. Conclusion Use of Seattle-PAP to implement Bn-CPAP lowers the effort of breathing exerted even by relatively healthy spontaneously breathing premature neonates. Whether the lower effort of breathing observed with Seattle-PAP translates to improvements in neonatal mortality or morbidity will need to be determined by studies in appropriate patient populations. PMID:29590143

  8. Role of Positive Airway Pressure Therapy for Obstructive Sleep Apnea in Patients With Stroke: A Randomized Controlled Trial

    Science.gov (United States)

    Gupta, Anupama; Shukla, Garima; Afsar, Mohammed; Poornima, Shivani; Pandey, Ravindra M.; Goyal, Vinay; Srivastava, Achal; Vibha, Deepti; Behari, Madhuri

    2018-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is an independent risk factor for stroke. The objective of this study was to assess the effect of continuous positive airway pressure (CPAP) treatment on prevention of new vascular events among patients with stroke and OSA. Methods: Consecutive conscious patients presenting with first imaging-confirmed arterial stroke were included, 6 weeks or more after ictus. All patients underwent clinical and polysomnography (PSG) testing. Patients with an apnea-hypopnea index (AHI) of > 15 events/h were randomized to posttitration nightly CPAP treatment and non-CPAP (received best medical treatment) groups. On follow-up at 3, 6, and 12 months from randomization, evaluation was carried out for any new vascular events as the primary outcome measure, and for clinical stroke outcomes (using the Barthel Index and modified Rankin scale) and neuropsychological parameters as the secondary outcome measures. Results: Among the 679 patients with stroke who were screened, 116 reported for PSG, 83 had AHI > 15 events/h, and 70 (34 in CPAP and 36 in non-CPAP) were randomized. Thirteen patients could not be randomized because of a lack of CPAP devices. Four patients crossed over from the CPAP to the non-CPAP group. Age (mean age 53.41 ± 9.85 in CPAP versus 52.69 ± 13.23 years in non-CPAP, P = .81) and sex distribution (24 males in CPAP versus 33 males in non-CPAP, P = .79) were similar in both groups. At 12-month follow-up, there was 1 vascular event (3.33%) in the CPAP group and 6 events (15%) in the non-CPAP group (P = .23). Modified Rankin scale score improvement by ≥ 1 at 12-month follow-up was found in significantly more patients in the CPAP group than in the non-CPAP group (53% versus 27%). Conclusions: These findings suggest significantly better stroke outcomes and statistically nonsignificant favorable outcomes in terms of recurrence of vascular events for patients with stroke and OSA who use CPAP treatment. Clinical Trial

  9. Positive airway pressure treatment

    Science.gov (United States)

    ... it. After using PAP regularly, you may notice: Better concentration and memory Feeling more alert and less sleepy during the day Improved sleep for your bed partner Being more productive at ... and a better mood Normal sleep patterns Lower blood pressure (in ...

  10. Interaction between intra-abdominal pressure and positive-end expiratory pressure

    Directory of Open Access Journals (Sweden)

    Jamili Anbar Torquato

    2009-02-01

    Full Text Available OBJECTIVE: The aim of this study was to quantify the interaction between increased intra-abdominal pressure and Positive-End Expiratory Pressure. METHODS: In 30 mechanically ventilated ICU patients with a fixed tidal volume, respiratory system plateau and abdominal pressure were measured at a Positive-End Expiratory Pressure level of zero and 10 cm H2O. The measurements were repeated after placing a 5 kg weight on the patients' belly. RESULTS: After the addition of 5 kg to the patients' belly at zero Positive-End Expiratory Pressure, both intra-abdominal pressure (p<0.001 and plateau pressures (p=0.005 increased significantly. Increasing the Positive-End Expiratory Pressure levels from zero to 10 cm H2O without weight on the belly did not result in any increase in intra-abdominal pressure (p=0.165. However, plateau pressures increased significantly (p< 0.001. Increasing Positive-End Expiratory Pressure from zero to 10 cm H2O and adding 5 kg to the belly increased intra-abdominal pressure from 8.7 to 16.8 (p<0.001 and plateau pressure from 18.26 to 27.2 (p<0.001. Maintaining Positive-End Expiratory Pressure at 10 cm H2O and placing 5 kg on the belly increased intra-abdominal pressure from 12.3 +/- 1.7 to 16.8 +/- 1.7 (p<0.001 but did not increase plateau pressure (26.6+/-1.2 to 27.2 +/-1.1 -p=0.83. CONCLUSIONS: The addition of a 5kg weight onto the abdomen significantly increased both IAP and the airway plateau pressure, confirming that intra-abdominal hypertension elevates the plateau pressure. However, plateau pressure alone cannot be considered a good indicator for the detection of elevated intra-abdominal pressure in patients under mechanical ventilation using PEEP. In these patients, the intra-abdominal pressure must also be measured.

  11. Auto-titrating continuous positive airway pressure treatment for obstructive sleep apnoea after acute quadriplegia (COSAQ): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Berlowitz, David J; Ayas, Najib; Barnes, Maree; Brown, Douglas J; Cistulli, Peter A; Geraghty, Tim; Graham, Alison; Lee, Bonsan Bonne; Morris, Meg; O'Donoghue, Fergal; Rochford, Peter D; Ross, Jack; Singhal, Balraj; Spong, Jo; Wadsworth, Brooke; Pierce, Robert J

    2013-06-19

    Quadriplegia is a severe, catastrophic injury that predominantly affects people early in life, resulting in lifelong physical disability. Obstructive sleep apnoea is a direct consequence of quadriplegia and is associated with neurocognitive deficits, sleepiness and reduced quality of life. The usual treatment for sleep apnoea is nasal continuous positive airway pressure (CPAP); however, this is poorly tolerated in quadriplegia. To encourage patients to use this therapy, we have to demonstrate that the benefits outweigh the inconvenience. We therefore propose a prospective, multinational randomized controlled trial of three months of CPAP for obstructive sleep apnoea after acute quadriplegia. Specialist spinal cord injury centres across Australia, New Zealand, the UK and Canada will recruit medically stable individuals who have sustained a (new) traumatic quadriplegia (complete or incomplete second cervical to first thoracic level lesions). Participants will be screened for obstructive sleep apnoea using full, portable sleep studies. Those with an apnoea hypopnoea index greater than 10 per hour will proceed to an initial three-night trial of CPAP. Those who can tolerate CPAP for at least 4 hours on at least one night of the initial trial will be randomized to either usual care or a 3-month period of auto-titrating CPAP. The primary hypothesis is that nocturnal CPAP will improve neuropsychological functioning more than usual care alone. The secondary hypothesis is that the magnitude of improvement of neuropsychological function will be predicted by the severity of baseline sleepiness measures, sleep fragmentation and sleep apnoea. Neuropsychological tests and full polysomnography will be performed at baseline and 3 months with interim measures of sleepiness and symptoms of autonomic dysfunction measured weekly. Spirometry will be performed monthly. Neuropsychological tests will be administered by blinded assessors. Recruitment commenced in July 2009. The results of

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Physical Therapy Coughing and Huffing High-Frequency Chest Wall Oscillation Positive Expiratory Pressure Clinical Trials Clinical Trials ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  13. Sleeping Well Trial: Increasing the effectiveness of treatment with continuous positive airway pressure using a weight management program in overweight adults with obstructive sleep apnoea-A stepped wedge randomised trial protocol.

    Science.gov (United States)

    Truby, Helen; Edwards, Bradley A; O'Driscoll, Denise M; Young, Alan; Ghazi, Ladan; Bristow, Claire; Roem, Kerryn; Bonham, Maxine P; Murgia, Chiara; Day, Kaitlin; Haines, Terry P; Hamilton, Garun S

    2018-05-24

    The majority of adults diagnosed with obstructive sleep apnoea (OSA) are overweight or obese. Continuous positive airway pressure (CPAP) is the most common effective therapy for OSA. However, adherence declines over time with only 50% of patients prescribed CPAP continuing to use it long term. Furthermore, a recent prospective analysis indicated that those more adherent with CPAP therapy have enhanced weight gain trajectories which in turn may negatively impact their OSA. The Sleeping Well Trial aims to establish whether the timing of starting a lifestyle weight loss intervention impacts on weight trajectory in those with moderate-severe OSA treated at home with CPAP, while testing the potential for smart phone technology to improve adherence with lifestyle interventions. A stepped wedge design with randomisation of individuals from 1 to 6 months post-enrolment, with 5 months of additional prospective follow up after completion of the stepped wedge. This design will investigate the effect of the 6-month lifestyle intervention on people undergoing CPAP on body weight, body composition and health-related quality of life. This trial tests whether the timing of supporting the patient through a weight loss intervention is important in obtaining the maximum benefit of a lifestyle change and CPAP usage, and identify how best to support patients through this critical period. The protocol (v1) is registered prospectively with the International Clinical Trials Registry (CTR) ACTRN12616000203459 (public access). Any amendments to protocol will be documented via the CTR. Recruitment commenced in March 2016 with data collection scheduled to finish by May 2018. © 2018 Dietitians Association of Australia.

  14. Dynamic Characteristics of Mechanical Ventilation System of Double Lungs with Bi-Level Positive Airway Pressure Model

    Directory of Open Access Journals (Sweden)

    Dongkai Shen

    2016-01-01

    Full Text Available In recent studies on the dynamic characteristics of ventilation system, it was considered that human had only one lung, and the coupling effect of double lungs on the air flow can not be illustrated, which has been in regard to be vital to life support of patients. In this article, to illustrate coupling effect of double lungs on flow dynamics of mechanical ventilation system, a mathematical model of a mechanical ventilation system, which consists of double lungs and a bi-level positive airway pressure (BIPAP controlled ventilator, was proposed. To verify the mathematical model, a prototype of BIPAP system with a double-lung simulators and a BIPAP ventilator was set up for experimental study. Lastly, the study on the influences of key parameters of BIPAP system on dynamic characteristics was carried out. The study can be referred to in the development of research on BIPAP ventilation treatment and real respiratory diagnostics.

  15. Responses to negative pressure surrounding the neck in anesthetized animals.

    Science.gov (United States)

    Wolin, A D; Strohl, K P; Acree, B N; Fouke, J M

    1990-01-01

    Continuous positive pressure applied at the nose has been shown to cause a decrease in upper airway resistance. The present study was designed to determine whether a similar positive transmural pressure gradient, generated by applying a negative pressure at the body surface around the neck, altered upper airway patency. Studies were performed in nine spontaneously breathing anesthetized supine dogs. Airflow was measured with a pneumotachograph mounted on an airtight muzzle placed over the nose and mouth of each animal. Upper airway pressure was measured as the differential pressure between the extrathoracic trachea and the inside of the muzzle. Upper airway resistance was monitored as an index of airway patency. Negative pressure (-2 to -20 cmH2O) was applied around the neck by using a cuirass extending from the jaw to the thorax. In each animal, increasingly negative pressures were transmitted to the airway wall in a progressive, although not linear, fashion. Decreasing the pressure produced a progressive fall in upper airway resistance, without causing a significant change in respiratory drive or respiratory timing. At -5 cmH2O pressure, there occurred a significant fall in upper airway resistance, comparable with the response of a single, intravenous injection of sodium cyanide (0.5-3.0 mg), a respiratory stimulant that produces substantial increases in respiratory drive. We conclude that upper airway resistance is influenced by the transmural pressure across the airway wall and that such a gradient can be accomplished by making the extraluminal pressure more negative.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Negative Pressure Pulmonary Edema Following use of Laryngeal Mask Airway (LMA

    Directory of Open Access Journals (Sweden)

    Yesim Bayraktar

    2013-06-01

    Full Text Available Negative pressure pulmonary edema (NPPE following upper airway obstruction is a non-cardiogenic pulmonary edema. The first cause in the etiology of NPPE is developed laryngospasm after intubation or extubation, while the other causes are epiglotitis, croup, hiccups, foreign body aspiration, pharyngeal hematoma and oropharyngeal tumors.The Late diagnosis and treatment causes high morbidity and mortality. The protection of the airway and maintainance of arterial oxygenation will be life saving.In this article we aimed to report  a case of negative pressure pulmonary edema, resolved succesfully after treatment, following use of laryngeal mask airway (LMA.

  17. Customized bubble continuous positive airway pressure (BCPAP ...

    African Journals Online (AJOL)

    owner

    2013-02-09

    Feb 9, 2013 ... our institution, we modified the existing Bubble CPAP devise using readily available but far less expensive materials. The resultant product is cheap, easily assem- .... Hurd SS, Bryan MH, Cotton RB,. Epstein MF et al. is chronic lung disease in low birth weight infants preventable? Pediatrics 1987; 9. (1):26- ...

  18. Effect of Pneumoperitoneum and Lateral Position on Oropharyngeal Seal Pressures of Proseal LMA in Laparoscopic Urological Procedures.

    Science.gov (United States)

    Rustagi, Preeti; Patkar, Geeta A; Ourasang, Anil Kumar; Tendolkar, Bharati A

    2017-02-01

    A sustained and effective oropharyngeal sealing with supraglottic airway is required to maintain the ventilation during laparoscopic surgery. Previous studies have observed the Oropharyngeal Seal Pressure (OSP) for Proseal Laryngeal Mask Airway (PLMA) after pneumoperitoneum in supine and trendelenburg position, where PLMA was found to be an effective airway device. This study was conducted with ProSeal LMA, for laparoscopic Urologic procedures done in lateral position. To measure OSP in supine and lateral position and to observe the effect of pneumoperitoneum in lateral position on OSP. Secondary objectives were to assess adequacy of ventilation and incidence of adverse events. A total number of 25 patients of American Society of Anaesthesiologists (ASA) physical status II and I were enrolled. After induction of anaesthesia using a standardized protocol, PLMA was inserted. Ryle's tube was inserted through drain tube. The position of PLMA was confirmed with ease of insertion of Ryle's tube and fibreoptic grading of vocal cords. Patients were then put in lateral position. The OSP was measured in supine position. This value was baseline comparison for OSP in lateral position and that after pneumoperitoneum. We assessed the efficacy of PLMA for ventilation, after carboperitoneum in lateral position (peak airway pressure, End Tidal Carbon dioxide (EtCO 2 ), SPO 2 ). Incidence of adverse effects (displacement of device, gastric insufflation, regurgitation, coughing, sore throat, blood on device, trauma) was also noted. The OSP was above Peak Airway Pressure (PAP) in supine (22.1±5.4 and 15.4±4.49cm of H 2 O) and lateral position (22.6±5.3 and 16.1±4.6). After pneumoperitoneum, which was in lateral position, there was statistically significant (p-value <0.05) increase in both PAP (19.96±4.015) and OSP (24.32±4.98, p-value 0.03). There was no intraoperative displacement of PLMA. There was no event of suboptimal oxygenation. EtCO 2 was always within normal limits

  19. Patient education combined in a music and habit-forming intervention for adherence to continuous positive airway (CPAP) prescribed for sleep apnea.

    Science.gov (United States)

    Smith, Carol E; Dauz, Emily; Clements, Faye; Werkowitch, Marilyn; Whitman, Robert

    2009-02-01

    As many as 50% of patients diagnosed with obstructive sleep apnea stop adhering to the prescribed medical treatment of continuous positive airway pressure (CPAP) within 1-3 weeks of onset. Thus, a theory-based intervention using music to support habit formation was designed to improve CPAP adherence at onset. The intervention materials included directions for CPAP nightly use, a diary for recording nightly use and writing about CPAP benefits or problems. In addition, an audiotape with softly spoken instructions for placing the CPAP mask comfortably, using deep breathing and muscle relaxation along with the slowly decreasing music tempo was provided to listen to at bedtime each night. Effects of this music intervention were tested in a randomized, placebo-controlled trial of 97 patients with 53 males (55%) and 44 females (45%). Moderate to severe apnea/hyponea scores (per sleep laboratory data) and medical diagnosis of OSA were required for study inclusion. Compared to placebo controls, a greater proportion of experimental patients were adhering (chi(2)=14.67, peffect for improving adherence to CPAP at 1 month. Adherence at the onset of treatment is critical and the audio music intervention was easily administered. Other interventions that target problems interfering with longer-term CPAP adherence are needed.

  20. Impact of heated humidification with automatic positive airway pressure in obstructive sleep apnea therapy.

    Science.gov (United States)

    Salgado, Sara Moreira da Silva Trindade; Boléo-Tomé, José Pedro Correia Fernandes; Canhão, Cristina Maria Sardinha; Dias, Ana Rita Tavares; Teixeira, Joana Isaac; Pinto, Paula Maria Gonçalves; Caetano, Maria Cristina de Brito Eusébio Bárbara Prista

    2008-09-01

    To study the impact that heated humidification instituted in the beginning of automatic positive airway pressure (APAP) therapy has on compliance with and the side effects of the treatment. Thirty-nine treatment-naïve patients with obstructive sleep apnea were randomized into two groups to receive APAP using one of two modalities: with heated humidification (APAPwith group); and without heated humidification (APAPw/o group).Patients were evaluated at 7 and 30 days after APAP initiation. The following parameters were analyzed: compliance with treatment (mean number of hours/night); side effects (dry nose or mouth, nasal obstruction and rhinorrhea); daytime sleepiness (Epworth sleepiness scale score) and subjective comfort (visual analog scale score). Patients were also evaluated in terms of residual apnea-hypopnea index (AHI), as well as mean pressures and leaks registered in the ventilators. There were no differences between the two groups in terms of mean age (APAPwith: 57.4 +/- 9.2; APAPw/o: 56.5 +/- 10.7 years), AHI (APAPwith: 28.1 +/- 14.0; APAPw/o: 28.8 +/- 20.5 events/hour of sleep), baseline Epworth score (APAPwith: 11.2 +/- 5.8; APAPw/o: 11.9 +/- 6.3) and initial nasal symptoms. Compliance was similar in both groups (APAPwith: 5.3 +/- 2.4; APAPw/o: 5.2 +/- 2.3 h/night). There were no differences in any of the other parameters analyzed. The introduction of heated humidification at the beginning of APAP therapy provided no advantage in terms of treatment compliance or side effects of treatment.

  1. [Treatment compliance with continuous positive airway pressure device among adults with obstructive sleep apnea (OSA): how many adhere to treatment?].

    Science.gov (United States)

    Sarrell, E Michael; Chomsky, Ofer; Shechter, Dalia

    2013-03-01

    Obstructive sleep apnea syndrome (OSA) afflicts approximately 5% of the adult population and increases with age. The gold standard treatment is with the Continuous Positive Airways Pressure (CPAP) machine. Well-designed prospective trials to elucidate long term compliance with CPAP machine are rare. Assessing compliance and long-term use of CPAP machines among patients with OSA who were referred for treatment with this machine. A 4 years prospective cohort observational study was conducted using telephone interviews of 371 newly diagnosed patients with moderate to severe OSA, who received a specialist recommendation to use the CPAP machine which was bought and adjusted to their use. At the end of the first year, 126 (34%) of the OSA patients used the CPAP machine on a nightly basis (regular users), 120 (32.3%) had not used it at all, and 125 (33.7%) had used it only intermittently. The number of regular users increased between the 1st and 2nd year from 126 (34%), to 163 (44%) (p < 0.07) due to additions from the intermittent users group. The non-users group grew from 120 (32.3%) in the first year, and every year afterwards, up to 221 (59.6%) in the fourth year (p < 0.02). In contrast, there was a significant decrease in the intermittent users group, which declined from 125 (33.7%) in the first year to only 18 (4.8%) in the 4th year (p < 0.005). Most of the patients (92.9%) were males. The average age of the regular users was 59.6 years (+/- 11), which was higher in comparison to 55.9 years (+/- 10.3) for the non-users or 58.9 years (+/- 12.6) among the intermittent users (p = 0.064). There were no statistical differences in co-morbidities or demographics between the three groups. However, the regular users were found to have a higher score in the Epworth Sleepiness Scale (ESS) and a minimal arterial oxygen saturation (SaO2) level lower than the patients in the non-users and intermittent users groups (p = 0.019 and p = 0.03 respectively). Four years follow

  2. Adherence to Positive Airway Therapy After Switching From CPAP to ASV: A Big Data Analysis.

    Science.gov (United States)

    Pépin, Jean-Louis D; Woehrle, Holger; Liu, Dongquan; Shao, Shiyun; Armitstead, Jeff P; Cistulli, Peter A; Benjafield, Adam V; Malhotra, Atul

    2018-01-15

    There is a lack of data regarding adherence trajectories when switching from continuous positive airway pressure (CPAP) to adaptive servoventilation (ASV) in the context of persistent or treatment-emergent central sleep apnea (CSA). This study investigated 90-day adherence rates in patients with sleep apnea based on the type of positive airway pressure (PAP) device used and any switching of PAP modality over time. Telemonitoring data were obtained from a United States PAP database. Eligible patients were a 30% random sample who started PAP, plus all who started ASV, from January 1, 2015 to October 2, 2015. All received PAP and had at least one session with usage of 1 hour or more. Adherence and device usage were determined in three groups: started on CPAP and stayed on CPAP (CPAP only); started on ASV and stayed on ASV (ASV only); started on CPAP, switched to ASV (Switch). The United States Medicare definition of adherence was used. The study included 198,890 patients; 189,724 (CPAP only), 8,957 (ASV only) and 209 (Switch). In the Switch group, average apnea-hypopnea index decreased significantly on ASV versus CPAP. At 90 days, adherence rates were 73.8% and 73.2% in the CPAP only and ASV only groups. In the Switch group, CPAP adherence was 62.7%, improving to 76.6% after the switch to ASV. Mean device usage at 90 days was 5.27, 5.31, and 5.73 h/d in the CPAP only, ASV only, and Switch groups, respectively. Treatment-emergent or persistent CSA during CPAP reduced therapy adherence, but adherence improved early after switching from CPAP to ASV. © 2018 American Academy of Sleep Medicine

  3. Effects of heated humidification and topical steroids on compliance, nasal symptoms, and quality of life in patients with obstructive sleep apnea syndrome using nasal continuous positive airway pressure.

    LENUS (Irish Health Repository)

    Ryan, Silke

    2012-02-01

    BACKGROUND: Nasal side effects are common in patients with obstructive sleep apnea syndrome (OSAS) starting on nasal continuous positive airway pressure (CPAP) therapy. We tested the hypothesis that heated humidification or nasal topical steroids improve compliance, nasal side effects and quality of life in this patient group. METHODS: 125 patients with the established diagnosis of OSAS (apnea\\/hypopnea index > or = 10\\/h), who tolerated CPAP via a nasal mask, and who had a successful CPAP titration were randomized to 4 weeks of dry CPAP, humidified CPAP or CPAP with additional topical nasal steroid application (fluticasone, GlaxoWellcome). Groups were similar in all demographic variables and in frequency of nasal symptoms at baseline. Outcome measures were objective compliance, quality of life (short form 36), subjective sleepiness (Epworth Sleepiness Scale score) and nasal symptoms such as runny, dry or blocked nose, sneezing and headaches; all variables assessed using a validated questionnaire and by direct interview. RESULTS: There was no difference in compliance between groups after 4 weeks (dry: 5.21 +\\/- 1.66 h\\/night, fluticasone: 5.66 +\\/- 1.68, humidifier: 5.21 +\\/- 1.84; p = 0.444). Quality of life and subjective sleepiness improved in all groups, but there were no differences in the extent of improvement. Nasal Symptoms were less frequently reported in the humidifier group (28%) than in the remaining groups (dry: 70%, fluticasone: 53%, p = 0.002). However, the addition of fluticasone resulted in increased frequency of sneezing. CONCLUSION: The addition of a humidifier, but not nasal steroids decreases the frequency of nasal symptoms in unselected OSAS patients initiating CPAP therapy; however compliance and quality of life remain unaltered.

  4. Treatment of obstructive sleep apnea syndrome with nasal positive airway pressure improves golf performance.

    Science.gov (United States)

    Benton, Marc L; Friedman, Neil S

    2013-12-15

    Obstructive sleep apnea syndrome (OSAS) is associated with impairment of cognitive function, and improvement is often noted with treatment. Golf is a sport that requires a range of cognitive skills. We evaluated the impact of nasal positive airway pressure (PAP) therapy on the handicap index (HI) of golfers with OSAS. Golfers underwent a nocturnal polysomnogram (NPSG) to determine whether they had significant OSAS (respiratory disturbance index > 15). Twelve subjects with a positive NPSG were treated with PAP. HI, an Epworth Sleepiness Scale (ESS), and sleep questionnaire (SQ) were submitted upon study entry. After 20 rounds of golf on PAP treatment, the HI was recalculated, and the questionnaires were repeated. A matched control group composed of non-OSAS subjects was studied to assess the impact of the study construct on HI, ESS, and SQ. Statistical comparisons between pre- and post-PAP treatment were calculated. The control subjects demonstrated no significant change in HI, ESS, or SQ during this study, while the OSAS group demonstrated a significant drop in average HI (11.3%, p = 0.01), ESS, (p = 0.01), and SQ (p = 0.003). Among the more skilled golfers (defined as HI ≤ 12), the average HI dropped by an even greater degree (31.5%). Average utilization of PAP was 91.4% based on data card reporting. Treatment of OSAS with PAP enhanced performance in golfers with this condition. Treatment adherence was unusually high in this study. Non-medical performance improvement may be a strong motivator for selected subjects with OSAS to seek treatment and maximize adherence.

  5. A prospective study to evaluate and compare laryngeal mask airway ProSeal and i-gel airway in the prone position.

    Science.gov (United States)

    Taxak, Susheela; Gopinath, Ajith; Saini, Savita; Bansal, Teena; Ahlawat, Mangal Singh; Bala, Manju

    2015-01-01

    Prone position is commonly used to provide surgical access to a variety of surgeries. In view of the advantages of induction of anesthesia in the prone position, we conducted a randomized study to evaluate and compare ProSeal laryngeal mask airway (LMA) and i-gel in the prone position. Totally, 40 patients of either sex as per American Society of Anesthesiologists physical status I or II, between 16 and 60 years of age, scheduled to undergo surgery in prone position were included in the study. After the patients positioned themselves prone on the operating table, anesthesia was induced by the standard technique. LMA ProSeal was used as an airway conduit in group 1 while i-gel was used in group 2. At the end of surgery, the airway device was removed in the same position. Insertion of airway device was successful in first attempt in 16, and 17 cases in ProSeal laryngeal mask airway (PLMA) and i-gel groups, respectively. A second attempt was required to secure the airway in 4 and 3 patients in PLMA and i-gel groups, respectively. The mean insertion time was 21.8 ± 2.70 s for group 1 and 13.1 ± 2.24 s for group 2, the difference being statistically significant (P position. The PLMA has a better seal while insertion is easier with i-gel.

  6. Continuous positive air pressure improves orthonasal olfactory function of patients with obstructive sleep apnea.

    Science.gov (United States)

    Walliczek-Dworschak, Ute; Cassel, Werner; Mittendorf, Luisa; Pellegrino, Robert; Koehler, Ulrich; Güldner, Christian; Dworschak, Philipp Otto Georg; Hildebrandt, Olaf; Daniel, Hanna; Günzel, Thomas; Teymoortash, Afshin; Hummel, Thomas

    2017-06-01

    Recent studies have suggested that patients with obstructive sleep apnea (OSA) might be affected by olfactory impairment. However, more evidence is needed on the effect that OSA has on the chemical senses (olfaction and gustatory) of these patients, and whether continuous positive airway pressure (CPAP) treatment might help to reverse possible impairment. A prospective study was conducted with 44 OSA patients (17 female and 27 male, mean age 54 ± 9.9 years) who were diagnosed via polysomnography and eligible for CPAP treatment. Orthonasal olfactory and gustatory function was measured with the extended Sniffin' Sticks test battery and "taste strips," respectively, before and after CPAP treatment. Baseline olfaction was decreased in OSA patients and after CPAP therapy olfactory scores (odor threshold-discrimination-identification score [TDI]: baseline 29.4 ± 4.11 after CPAP 32.3 ± 4.82; p = 0.001; odor threshold [THR]: baseline 5.28 ± 1.69 after CPAP 6.78 ± 2.61; p = 0.000; odor identification [ID]: baseline 12.9 ± 1.95 after CPAP 13.6 ± 1.33; p = 0.013) improved significantly. In contrast, neither baseline taste function in OSA patients nor gustatory function after treatment seemed to be affected. Orthonasal olfactory function in patients with OSA improves under CPAP therapy; however, gustatory function is not impaired in OSA patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. The 30-year evolution of airway pressure release ventilation (APRV).

    Science.gov (United States)

    Jain, Sumeet V; Kollisch-Singule, Michaela; Sadowitz, Benjamin; Dombert, Luke; Satalin, Josh; Andrews, Penny; Gatto, Louis A; Nieman, Gary F; Habashi, Nader M

    2016-12-01

    Airway pressure release ventilation (APRV) was first described in 1987 and defined as continuous positive airway pressure (CPAP) with a brief release while allowing the patient to spontaneously breathe throughout the respiratory cycle. The current understanding of the optimal strategy to minimize ventilator-induced lung injury is to "open the lung and keep it open". APRV should be ideal for this strategy with the prolonged CPAP duration recruiting the lung and the minimal release duration preventing lung collapse. However, APRV is inconsistently defined with significant variation in the settings used in experimental studies and in clinical practice. The goal of this review was to analyze the published literature and determine APRV efficacy as a lung-protective strategy. We reviewed all original articles in which the authors stated that APRV was used. The primary analysis was to correlate APRV settings with physiologic and clinical outcomes. Results showed that there was tremendous variation in settings that were all defined as APRV, particularly CPAP and release phase duration and the parameters used to guide these settings. Thus, it was impossible to assess efficacy of a single strategy since almost none of the APRV settings were identical. Therefore, we divided all APRV studies divided into two basic categories: (1) fixed-setting APRV (F-APRV) in which the release phase is set and left constant; and (2) personalized-APRV (P-APRV) in which the release phase is set based on changes in lung mechanics using the slope of the expiratory flow curve. Results showed that in no study was there a statistically significant worse outcome with APRV, regardless of the settings (F-ARPV or P-APRV). Multiple studies demonstrated that P-APRV stabilizes alveoli and reduces the incidence of acute respiratory distress syndrome (ARDS) in clinically relevant animal models and in trauma patients. In conclusion, over the 30 years since the mode's inception there have been no strict

  8. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water

    Directory of Open Access Journals (Sweden)

    Danize Aparecida Rizzetti

    Full Text Available ABSTRACT Objective: To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. Methods: This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP; CPAP5 (CPAP at 5 cmH2O; and CPAP10 (CPAP at 10 cmH2O. We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR, and FEF25-75% at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. Results: We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. Conclusions: When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.

  9. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water.

    Science.gov (United States)

    Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel

    2017-01-01

    To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expiratory flow rate (PEFR), and FEF25-75%) at three time points: pre-immersion; 10 min after immersion; and 10 min after the end of each protocol. We evaluated 13 healthy volunteers. The CPAP10 protocol reversed the restrictive pattern of lung function induced by immersion in water, maintaining pulmonary volumes and capacities for a longer period than did the CPAP5 protocol. When the hemodynamic change causing a persistent lung disorder, only the application of higher positive pressures is effective in maintaining long-term improvements in the pulmonary profile.

  10. Utility of formulas predicting the optimal nasal continuous positive airway pressure in a Greek population.

    Science.gov (United States)

    Schiza, Sophia E; Bouloukaki, Izolde; Mermigkis, Charalampos; Panagou, Panagiotis; Tzanakis, Nikolaos; Moniaki, Violeta; Tzortzaki, Eleni; Siafakas, Nikolaos M

    2011-09-01

    There have been reports that optimal CPAP pressure can be predicted from a previously derived formula, with the Hoffstein formula being the most accurate and accepted in the literature so far. However, the validation of this predictive model has not been applied in different clinical settings. Our aim was to compare both the Hoffstein prediction formula and a newly derived formula to the CPAP pressure setting assessed during a formal CPAP titration study. We prospectively studied 1,111 patients (871 males/240 females) with obstructive sleep apnea hypopnea syndrome (OSAHS) undergoing a CPAP titration procedure. In this large population sample, we tested the Hoffstein formula, utilizing body mass index (BMI), neck circumference and apnea/hypopnea index (AHI), and we compared it with our new formula that included not only AHI and BMI but also smoking history and gender adjustment. We found that using the Hoffstein prediction formula, successful prediction (predicted CPAP pressure within ±2 cm H(2)O compared to the finally assessed optimum CPAP pressure during titration) was accomplished in 873 patients (79%), with significant correlation between CPAP predicted pressure (CPAPpred(1)) and the optimum CPAP pressure (CPAPopt) [r = 0.364, p history and gender adjustment, successful prediction was accomplished in 1,057 patients (95%), with significant correlation between CPAP predicted pressure (CPAPpred(2)) and the CPAPopt (r = 0.392, p titration. It may also be possible to shorten CPAP titration and perhaps in selected cases to combine it with the initial diagnostic study.

  11. The classical Starling resistor model often does not predict inspiratory airflow patterns in the human upper airway.

    Science.gov (United States)

    Owens, Robert L; Edwards, Bradley A; Sands, Scott A; Butler, James P; Eckert, Danny J; White, David P; Malhotra, Atul; Wellman, Andrew

    2014-04-15

    The upper airway is often modeled as a classical Starling resistor, featuring a constant inspiratory airflow, or plateau, over a range of downstream pressures. However, airflow tracings from clinical sleep studies often show an initial peak before the plateau. To conform to the Starling model, the initial peak must be of small magnitude or dismissed as a transient. We developed a method to simulate fast or slow inspirations through the human upper airway, to test the hypothesis that this initial peak is a transient. Eight subjects [4 obstructive sleep apnea (OSA), 4 controls] slept in an "iron lung" and wore a nasal mask connected to a continuous/bilevel positive airway pressure machine. Downstream pressure was measured using an epiglottic catheter. During non-rapid eye movement (NREM) sleep, subjects were hyperventilated to produce a central apnea, then extrathoracic pressure was decreased slowly (∼2-4 s) or abruptly (resistor model, the upper airway exhibits marked NED in some subjects.

  12. A possible way to assess tidal exhaled nitric oxide in neonates and infants treated with nasal continuous positive airway pressure

    DEFF Research Database (Denmark)

    Schmidt, Birgitte Johanne; Reim, Pauline Schibler; Pedersen, Ole Find

    2018-01-01

    The endogenous compound nitric oxide (NO) is released into the airways via inducible NO synthase (1),which has the capacity to produce NO when up-regulated by pro-inflammatory cytokines or exogenous factors, like hypoxia, bacterial toxins and viruses (2). Prematurely born infants are susceptible...

  13. Oral appliance therapy versus nasal continuous positive airway pressure in obstructive sleep apnoea syndrome: a randomised, placebo-controlled trial on self-reported symptoms of common sleep disorders and sleep-related problems.

    Science.gov (United States)

    Nikolopoulou, M; Byraki, A; Ahlberg, J; Heymans, M W; Hamburger, H L; De Lange, J; Lobbezoo, F; Aarab, G

    2017-06-01

    Obstructive sleep apnoea syndrome (OSAS) is associated with several sleep disorders and sleep-related problems. Therefore, the aim of this study was to compare the effects of a mandibular advancement device (MAD) with those of nasal continuous positive airway pressure (nCPAP) on self-reported symptoms of common sleep disorders and sleep-related problems in mild and moderate OSAS patients. In this randomised placebo-controlled trial, sixty-four OSAS patients (52·0 ± 9·6 years) were randomly assigned to an MAD, nCPAP or an intra-oral placebo appliance in a parallel design. All participants filled out the validated Dutch Sleep Disorders Questionnaire (SDQ) twice: one before treatment and one after six months of treatment. With 88 questions, thirteen scales were constructed, representing common sleep disorders and sleep-related problems. Linear mixed model analyses were performed to study differences between the groups for the different SDQ scales over time. The MAD group showed significant improvements over time in symptoms corresponding with 'insomnia', 'excessive daytime sleepiness', 'psychiatric sleep disorder', 'periodic limb movements', 'sleep apnoea', 'sleep paralysis', 'daytime dysfunction', 'hypnagogic hallucinations/dreaming', 'restless sleep', 'negative conditioning' and 'automatic behaviour' (range of P values: 0·000-0·014). These improvements in symptoms were, however, not significantly different from the improvements in symptoms observed in the nCPAP and placebo groups (range of P values: 0·090-0·897). It can be concluded that there is no significant difference between MAD and nCPAP in their positive effects on self-reported symptoms of common sleep disorders and sleep-related problems in mild and moderate OSAS patients. These beneficial effects may be a result of placebo effects. © 2017 John Wiley & Sons Ltd.

  14. Positive pressure ventilation and cranial volume in newborn infants.

    OpenAIRE

    Milligan, D W

    1981-01-01

    The relationship between changes in airways pressure, pleural pressure, and cranial volume was studied in a group of sick newborn infants requiring ventilatory assistance. Cranial volume increased appreciably only when lung compliance was such that more than 20% of the applied airways pressure was transmitted to the pleural space, or if the absolute pleural pressure was greater than 4 cmH2O above atmospheric pressure. The findings stress the need for more-critical monitoring during periods of...

  15. Treatment of sleep central apnea with non-invasive mechanical ventilation with 2 levels of positive pressure (bilevel in a patient with myotonic dystrophy type 1

    Directory of Open Access Journals (Sweden)

    Ricardo Tera Akamine

    2014-06-01

    Bi-level positive airway pressure treatment at spontaneous/timed mode showed an improvement in snoring, apneas, and Epworth sleepiness scale decreased from 20 to 10. This case illustrates the beneficial effects of Bi-level positive airway pressure support in central sleep apnea syndrome of a patient with myotonic dystrophy type 1.

  16. [Study of setting of ventilator volume tidal and airway pressure alarm threshold with continuous extra-sternum heart compression in cardiopulmonary resuscitation].

    Science.gov (United States)

    Luo, Jian-yu; Wang, Xiao-yuan; Cai, Tian-bin; Jiang, Wen-fang

    2013-02-01

    To investigate the setting of ventilator volume tidal (VT) and airway pressure alarm threshold during cardiopulmonary resuscitation (CPR) by continuous extra-sternum heart compression. Forty cases with respiration and cardiac arrest in the department of critical care medicine were randomly divided into low VT ventilation group and conventional VT group. Both groups were given the volume control mode. In the low VT ventilation group, VT was set on 6 - 7 ml/kg, and high pressure alarm threshold was adjusted to 60 cm H2O by the conventional 40 cm H2O during CPR. In the conventional VT group, VT and high pressure alarm threshold were set at 8 - 12 ml/kg and 40 cm H2O, respectively. Real-time actual VT, peak inspiratory pressure (PIP), and arterial blood gas test, blood lactic acid at 10 minutes and 30 minutes after CPR were observed. At 10 minutes after CPR, in the low VT ventilation group, arterial blood pH, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2), HCO3(-), arterial oxygen saturation (SaO2) and blood lactic acid were better as compared with those in the conventional VT ventilation group (pH: 7.21±0.09 vs. 7.13±0.07, PaO2: 45.35±5.92 mm Hg vs. 40.70±4.70 mm Hg, PaCO2: 57.10±7.59 mm Hg vs. 61.60±5.47 mm Hg, HCO3(-): 18.50±3.50 mmol/L vs. 14.75±2.65 mmol/L, SaO2: 0.796±0.069 vs. 0.699±0.066, blood lactic acid: 7.07±1.60 mmol/L vs. 8.13±1.56 mmol/L, all P<0.05). The success rate of resuscitation in the low VT ventilation group was higher than that of the conventional VT ventilation group (45% vs. 15%, P<0.05), and PIP (cm H2O) of low VT ventilation group was lower than that of the conventional VT group (37.25±7.99 cm H2O vs. 42.70±7.40 cm H2O, P<0.05). In all the patients in both groups barotrauma did not occur. The strategy of low ventilator VT (6 - 7 ml/kg) with appropriate elevation of airway pressure alarm threshold was better than that of conventional ventilation setting, with no increase in

  17. Nasal Continuous Positive Airway Pressure Inhibits Gastroesophageal Reflux in Newborn Lambs

    Science.gov (United States)

    Djeddi, Djamal; Cantin, Danny; Samson, Nathalie; Praud, Jean-Paul

    2014-01-01

    Background Using esophageal pHmetry, nasal CPAP (nCPAP) has been shown to decrease acid gastroesophageal reflux (GER) in adult humans. Although both GER (mainly non-acid) and nCPAP use are very frequent in newborns, the effect of nCPAP on GER in early life is unknown. Having recently shown that the newborn lamb is a unique model for studying neonatal GER, our main objective was to assess the effect of nCPAP on GER in newborn lambs. Methods Eight newborn lambs, aged 2–3 days, were studied. Continuous esophageal pH-Impedance monitoring and polysomnography were performed for six hours during both spontaneous breathing and nCPAP application at 6 cmH2O (nCPAP6), in a randomized order. Results were compared in the two experimental conditions, as well as without CPAP during the following 6 hours. Results i) nCPAP6 virtually abolished GER [mean ±SD reflux number for 6 h = 9.1±8.6 without nCPAP6 vs. 0.6±1 with nCPAP6, PCPAP are needed to confirm this result in human infants. PMID:25226514

  18. Treatment of upper airway resistance syndrome in adults: Where do we stand?

    Directory of Open Access Journals (Sweden)

    Luciana B.M. de Godoy

    2015-01-01

    Full Text Available Objective: To evaluate the available literature regarding Upper Airway Resistance Syndrome (UARS treatment. Methods: Keywords “Upper Airway Resistance Syndrome,” “Sleep-related Breathing Disorder treatment,” “Obstructive Sleep Apnea treatment” and “flow limitation and sleep” were used in main databases. Results: We found 27 articles describing UARS treatment. Nasal continuous positive airway pressure (CPAP has been the mainstay therapy prescribed but with limited effectiveness. Studies about surgical treatments had methodological limitations. Oral appliances seem to be effective but their efficacy is not yet established. Conclusion: Randomized controlled trials with larger numbers of patients and long-term follow-up are important to establish UARS treatment options.

  19. Effects of continuous positive airway pressure on anxiety, depression, and major cardiac and cerebro-vascular events in obstructive sleep apnea patients with and without coronary artery disease.

    Science.gov (United States)

    Lee, Ming-Chung; Shen, Yu-Chih; Wang, Ji-Hung; Li, Yu-Ying; Li, Tzu-Hsien; Chang, En-Ting; Wang, Hsiu-Mei

    2017-01-01

    Obstructive sleep apnea (OSA) is associated with bad cardiovascular outcomes and a high prevalence of anxiety and depression. This study investigated the effects of continuous positive airway pressure (CPAP) on the severity of anxiety and depression in OSA patients with or without coronary artery disease (CAD) and on the rate of cardio- and cerebro-vascular events in those with OSA and CAD. This prospective study included patients with moderate-to-severe OSA, with or without a recent diagnosis of CAD; all were started on CPAP therapy. Patients completed the Chinese versions of the Beck Anxiety Inventory (BAI) and Beck Depression Inventory-II (BDI-II) at baseline and after 6-month follow-up. The occurrence of major adverse cardiac and cerebrovascular events (MACCE) was assessed every 3 months up to 1 year. BAI scores decreased from 8.5 ± 8.4 at baseline to 5.4 ± 6.9 at 6 months in CPAP-compliant OSA patients without CAD ( P < 0.05). BAI scores also decreased from 20.7 ± 14.9 to 16.1 ± 14.5 in CPAP-compliant OSA patients with CAD. BDI-II scores decreased in CPAP-compliant OSA patients without CAD (from 11.1 ± 10.7 at baseline to 6.6 ± 9.5 at 6 months) and in CPAP-compliant OSA patients with CAD (from 20.4 ± 14.3 to 15.9 ± 7.3). In addition, there was a large effect size (ES) of BAI and BDI in 6-month CPAP treatment of OSA patients with CAD and a large ES in those with OSA under CPAP treatment. In OSA patients with CAD, the occurrence of MACCE was significantly lower in CPAP-compliant patients than that in CPAP noncompliant patients (11% in CPAP compliant and 50% in noncompliant; P < 0.05). CPAP improved anxiety and depression in OSA patients regardless of CAD. In OSA patients with CAD, CPAP-compliant patients had a lower 1-year rate of MACCE than CPAP-noncompliant patients.

  20. The effect of continuous positive airway pressure on post-traumatic stress disorder symptoms in veterans with post-traumatic stress disorder and obstructive sleep apnea: a prospective study.

    Science.gov (United States)

    El-Solh, Ali A; Vermont, Leah; Homish, Gregory G; Kufel, Thomas

    2017-05-01

    Previous retrospective studies have shown that continuous positive airway pressure (CPAP) exerts salutary effect on post-traumatic stress disorder (PTSD) symptoms and nightmare distress. The relative magnitude of therapeutic benefits from CPAP and the strength of associations between duration of CPAP use and PTSD symptomatology are unknown. A prospective cohort design involving 47 combat veterans with PTSD and documented obstructive sleep apnea (OSA) by overnight polysomnography. Epworth Sleepiness Scale (ESS) score, PTSD checklist-Military (PCL-M), Nightmare Distress Questionnaire (NDQ), and Nightmare Frequency Questionnaire (NFQ) were administered at baseline and 3 months after CPAP therapy. Objective adherence was assessed at the 3-month follow-up. Twenty-two veterans with mild-to-moderate PTSD (PCL-M score 17-59) and 18 with severe-to-very-severe PTSD (PCL-M score 60-85) completed the study. There was a dose-dependent response of PCL-M to duration of CPAP usage (r = 0.45; p = 0.003). Veterans with severe-to-very-severe PTSD had a larger improvement in PTSD symptoms (d = 0.65; p = 0.004) compared with those with mild-to-moderate PTSD (d = 0.47; p = 0.04). CPAP usage was the only significant predictor of overall subjective improvement in PTSD symptoms (OR 10.5; p = 0.01). Significant changes in NDQ and NFQ scores following 3 months of treatment were observed in veterans adherent to CPAP, but the correlations with duration of CPAP use were not statistically significant (r = 0.24; p = 0.13 and r = 0.13; p = 0.4, respectively). Improvement of PTSD symptoms in veterans with OSA was more pronounced with prolonged use of CPAP. Adherence to treatment was linked to abatement in nightmare distress and frequency. Future investigation of multimodal treatment, including behavioral intervention combined with CPAP, is warranted. Published by Elsevier B.V.

  1. Elevated Extravascular Lung Water Index (ELWI) as a Predictor of Failure of Continuous Positive Airway Pressure Via Helmet (Helmet-CPAP) in Patients With Acute Respiratory Failure After Major Surgery.

    Science.gov (United States)

    Redondo Calvo, Francisco Javier; Bejarano Ramirez, Natalia; Uña Orejon, Rafael; Villazala Garcia, Ruben; Yuste Peña, Ana Sofia; Belda, Francisco Javier

    2015-11-01

    NIV is increasingly used for prevention and treatment of respiratory complications and failure. Some of them are admitted to the PACU with advanced hemodynamic monitors which allow quantification of Extravascular Lung Water (EVLW) by transpulmonary thermodilution technique (TPTD) and Pulmonary Vascular Permeability (PVP) providing information on lung edema. The objective of this study was to ascertain if EVLW Index and PVP Index may predict failure (intubation) or success (non-intubation) in patients developing acute respiratory failure (ARF) in the postoperative period following major abdominal surgery, where the first line of treatment was non-invasive continuous positive airway pressure via a helmet. Hemodynamic variables, EVLWI and PVPI were monitored with a transpulmonary thermodilution hemodynamic monitor device (PiCCO™) before and after the application of CPAP. Avoidance of intubation was observed in 66% of patients with Helmet-CPAP. In these patients after the first hour of application of CPAP, PaO2/FiO2 ratio significantly increased (303.33±65.2 vs. 141.6±14.6, P<.01). Before starting Helmet-CPAP values of EVLWI and PVPI were significantly lower in non-intubated patients (EVLWI 8.6±1.08 vs. 11.8±0.99ml/kg IBW, P<.01 and PVPI 1.7±0.56 vs. 3.0±0.88, P<.01). An optimal cut-off value for EVLWI was established at 9.5, and at 2.45 for PVPI (sensitivity of 0.7; specificity of 0.9, P<.01). In this type of patient the physiological parameters that predict the failure of Helmet-CPAP with the greatest accuracy were the value of the EVLWI and PVPI before Helmet-CPAP institution and the PaO2/FiO2 ratio and the respiratory rate after one hour of CPAP. Copyright © 2014 SEPAR. Published by Elsevier Espana. All rights reserved.

  2. High altitude pulmonary edema and exercise at 4,400 meters on Mount McKinley. Effect of expiratory positive airway pressure.

    Science.gov (United States)

    Schoene, R B; Roach, R C; Hackett, P H; Harrison, G; Mills, W J

    1985-03-01

    Breathing against positive expiratory pressure has been used to improve gas exchange in many forms of pulmonary edema, and forced expiration against resistance during exercise has been advocated for climbing at high altitude as a method to optimize performance. To evaluate the effect of expiratory positive airway pressure (EPAP) on climbers with high altitude pulmonary edema (HAPE) and on exercise at high altitude, we studied four climbers with HAPE at rest and 13 healthy climbers during exercise on a bicycle ergometer at 4400 m. We measured minute ventilation (VI, L/min), arterial oxygen saturation (SaO2 percent), end-tidal carbon dioxide (PACO2, mm Hg), respiratory rate (RR), and heart rate (HR) during the last minute of a five minute interval at rest in the climbers with HAPE, and at rest, 300, and 600 kpm/minute workloads on a bicycle ergometer in the healthy subjects. The HAPE subjects demonstrated an increased SaO2 percent, no change in HR or VI, and a decrease in RR on EPAP as compared to control. In normal subjects, SaO2 percent, VI, and heart rate were significantly higher on EPAP 10 cm H2O than 0 cm H2O control (p less than 0.01, 0.01, and 0.05, respectively). The RR and PaCO2 were not significantly different. In summary, EPAP improves gas exchange in HAPE subjects at rest. The EPAP in normal subjects at high altitude resulted in a higher SaO2 percent at the expense of a higher VI and higher HR. These results suggest that the work of breathing is higher and the stroke volume lower on EPAP. The positive pressure mask may be an effective temporizing measure for victims of HAPE who cannot immediately go to a lower altitude.

  3. Moderately high frequency ventilation with a conventional ventilator allows reduction of tidal volume without increasing mean airway pressure.

    Science.gov (United States)

    Cordioli, Ricardo Luiz; Park, Marcelo; Costa, Eduardo Leite Vieira; Gomes, Susimeire; Brochard, Laurent; Amato, Marcelo Britto Passos; Azevedo, Luciano Cesar Pontes

    2014-12-01

    The aim of this study was to explore if positive-pressure ventilation delivered by a conventional ICU ventilator at a moderately high frequency (HFPPV) allows a safe reduction of tidal volume (V T) below 6 mL/kg in a porcine model of severe acute respiratory distress syndrome (ARDS) and at a lower mean airway pressure than high-frequency oscillatory ventilation (HFOV). This is a prospective study. In eight pigs (median weight 34 [29,36] kg), ARDS was induced by pulmonary lavage and injurious ventilation. The animals were ventilated with a randomized sequence of respiratory rates: 30, 60, 90, 120, 150, followed by HFOV at 5 Hz. At each step, V T was adjusted to allow partial pressure of arterial carbon dioxide (PaCO2) to stabilize between 57 and 63 mmHg. Data are shown as median [P25th,P75th]. After lung injury, the PaO2/FiO2 (P/F) ratio was 92 [63,118] mmHg, pulmonary shunt 26 [17,31]%, and static compliance 11 [8,14] mL/cmH2O. Positive end-expiratory pressure (PEEP) was 14 [10,17] cmH2O. At 30 breaths/min, V T was higher than 6 (7.5 [6.8,10.2]) mL/kg, but at all higher frequencies, V T could be reduced and PaCO2 maintained, leading to reductions in plateau pressures and driving pressures. For frequencies of 60 to 150/min, V T progressively fell from 5.2 [5.1,5.9] to 3.8 [3.7,4.2] mL/kg (p mechanics, auto-PEEP generation, hemodynamics, or gas exchange. Mean airway pressure was maintained constant and was increased only during HFOV. During protective mechanical ventilation, HFPPV delivered by a conventional ventilator in a severe ARDS swine model safely allows further tidal volume reductions. This strategy also allowed decreasing airway pressures while maintaining stable PaCO2 levels.

  4. Nasal continuous positive airway pressure inhibits gastroesophageal reflux in newborn lambs.

    Directory of Open Access Journals (Sweden)

    Djamal Djeddi

    Full Text Available BACKGROUND: Using esophageal pHmetry, nasal CPAP (nCPAP has been shown to decrease acid gastroesophageal reflux (GER in adult humans. Although both GER (mainly non-acid and nCPAP use are very frequent in newborns, the effect of nCPAP on GER in early life is unknown. Having recently shown that the newborn lamb is a unique model for studying neonatal GER, our main objective was to assess the effect of nCPAP on GER in newborn lambs. METHODS: Eight newborn lambs, aged 2-3 days, were studied. Continuous esophageal pH-Impedance monitoring and polysomnography were performed for six hours during both spontaneous breathing and nCPAP application at 6 cmH2O (nCPAP(6, in a randomized order. Results were compared in the two experimental conditions, as well as without CPAP during the following 6 hours. RESULTS: i nCPAP(6 virtually abolished GER [mean ± SD reflux number for 6 h = 9.1 ± 8.6 without nCPAP(6 vs. 0.6 ± 1 with nCPAP(6, P<0.05]; ii GER number was also reduced during the 6 h-period following nCPAP(6 application (18 ± 16 without nCPAP(6 vs. 7 ± 8.1 with nCPAP(6, P<0.05; iii nCPAP(6 decreased the depth and duration of lower esophageal sphincter relaxation. CONCLUSIONS: nCPAP inhibits GER in the newborn lamb. Further clinical studies using different levels of nasal CPAP are needed to confirm this result in human infants.

  5. Randomized controlled trial of two methods of nasal continuous positive airway pressure (N-CPAP) in preterm infants with respiratory distress syndrome: underwater bubbly CPAP vs. Medijet system device.

    Science.gov (United States)

    Hosseini, Mohammad Bagher; Heidarzadeh, Mohammad; Balila, Masumeh; Ghojazadeh, Morteza; Janani, Raheleh; Safavi-nia, Sima; Naghavi-Behzad, Mohammad; Alikhah, Hossein

    2012-01-01

    There has been an increasing interest in the application of non-invasive respiratory support in preterm infants, and different types of nasal continuous positive airway pressure (N-CPAP) devices are being used in Neonatal Intensive Care Units (NICUs). The objective of the present study was to compare the duration of CPAP need and possible complications of two methods of (N-CPAP) delivery: Bubble CPAP (B-CPAP) and Medijet (MJ) system device in preterm infants with respiratory distress syndrome (RDS). This prospective randomized clinical trial was performed on 161 preterm infants (28-37 weeks of gestational age) with RDS and eligible for CPAP therapy. The infants were inborn and admitted in a level III NICU of Al-Zahra Teaching Hospital (Tabriz, Iran) from April 2010 to September 2011. All infants were randomized in the first hour of life to B-CPAP or MJ system. Short binasal prongs were used in both groups and CPAP was set at the level of 5-6 cm H2O. The primary outcome of this study was duration of CPAP need (hour). Other outcomes, such as complications of the two methods of N-CPAP, were evaluated using a checklist. Ninety infants were randomized to the MJ system, and 71 were randomized to B-CPAP. The mean gestational age and birth weight were similar in the two groups, as was the duration of CPAP need (44.3 ± 20.64 vs. 49.2 ± 21.2 hours, respectively; p=0.66). Moreover, the probability of complications, such as CPAP failure rate, pulmonary hemorrhage, pneumothorax, intraventricular hemorrhage, abdominal distention, necrotizing enterocolitis, and bronchopulmonary dysplasia, was the same between the two study groups (p>0.05). There was a trend of more hyperemia of the nose in the B-CPAP group in comparison to the MJ system group (10% versus 3.3%, respectively), but the difference was not significant (p=0.08). In conclusion, the MJ system is as effective as B-CPAP in the management of infants with RDS.

  6. Positive airway pressure adherence and mask interface in the setting of sinonasal symptoms.

    Science.gov (United States)

    Schell, Amy E; Soose, Ryan J

    2017-10-01

    Despite reports of lower positive pressure adherence rates with oronasal masks, patients with sinonasal problems are often prescribed this interface over a nasal interface. The aim of this study was to characterize the relationship between mask type and therapy adherence in the setting of sinonasal symptoms. Retrospective case series with chart review. We reviewed 328 patients who underwent positive pressure titration between January 2012 and May 2015. Follow-up adherence data were available for 218 patients (66.5%). Multivariate analysis examined whether patients with sinonasal symptoms have improved adherence with oronasal masks compared to nasal or nasal pillow interfaces. At a median follow-up of 95 days, positive pressure adherence in patients with sinonasal symptoms was highest with the nasal pillow interface. When compared with oronasal interfaces, the odds of adequate therapy adherence were >5 times greater with nasal pillow interfaces (odds ratio [OR] = 5.20, 95% confidence interval [CI] = 1.61-16.80, P = .006) and >3 times greater with nasal interfaces (OR = 3.67, 95% CI = 1.20-11.26, P = .02) in these symptomatic patients. The presence of nasal problems does not predict the need for an oronasal mask. Positive pressure adherence rates are higher with nasal and nasal pillow interfaces compared to oronasal masks, even in patients with sinonasal complaints. 4. Laryngoscope, 127:2418-2422, 2017. © 2016 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: March 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  8. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: June 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy ... clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall ...

  11. Airway Clearance Techniques (ACTs)

    Science.gov (United States)

    ... infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway ... Positive Expiratory Pressure High-Frequency Chest Wall Oscillation (the Vest) Follow ...

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing ... Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation ( ...

  13. Use of Respiratory Support in the Biphase Ventilation Airway Mode in the Newborn

    Directory of Open Access Journals (Sweden)

    S. N. Koval

    2006-01-01

    Full Text Available Biphasic positive airway pressure (BIPAP (also known as DuoPAP, BiLevel, BiVent, PCV+, SPAP is a mode of ventilation with cycling variations between two continuous positive airway pressure levels. It is a mixture of pressure controlled ventilation and spontaneous breathing, which is unrestricted in each phase of the respiratory cycle. The volume displacement caused by the difference between Phigh and Plow airway pressure level. The phase time ratio (PTR — the BIPAP frequency is calculated as the ratio between the durations of the two pressure phases, a PTR greater than 1:1 is called APRV (airway pressure release ventilation. In patients with ARDS maintained spontaneous breathing with BIPAP resulted in lower venous admixture and better arterial blood oxygenation as compared with A/C. Only a few studies with BIPAP have been performed in newborn and infants until now. We studied the use of BIPAP in newborn (body mass > 3kg and randomised 40 patients with respiratory failure for ventilation with BIPAP (n=20 or conventional mechanical ventilatory support (assist-control A/C — synchronised intermittent mandatory ventilation (SIMV (n=20. The Pediatric Risk of Mortality score (PRISM were collected for each patient. Fentanyl, diazepam, GABA were used as sedatives and adjusted in accordance with the Cook scale. We compared ventilatory parameters, information pertaining to pulmonary function and oxygen delivery, cardiac output, additional descriptors of organ system functions, duration and complications of ventilation and number and dosages of sedatives administered. All the patients that we intended to ventilate with BIPAP were successfully ventilated, we can conclude that biphasic ventilatory support suitable mode of ventilation for newborn with a decreased need of analgetics and sedatives than A/C. Finally, BIPAP is an a effective safe, and easy to use for personal mode of mechanical ventilatory support in newborn. 

  14. Comparison of airway pressure release ventilation to conventional mechanical ventilation in the early management of smoke inhalation injury in swine.

    Science.gov (United States)

    Batchinsky, Andriy I; Burkett, Samuel E; Zanders, Thomas B; Chung, Kevin K; Regn, Dara D; Jordan, Bryan S; Necsoiu, Corina; Nguyen, Ruth; Hanson, Margaret A; Morris, Michael J; Cancio, Leopoldo C

    2011-10-01

    The role of airway pressure release ventilation in the management of early smoke inhalation injury has not been studied. We compared the effects of airway pressure release ventilation and conventional mechanical ventilation on oxygenation in a porcine model of acute respiratory distress syndrome induced by wood smoke inhalation. Prospective animal study. Government laboratory animal intensive care unit. Thirty-three Yorkshire pigs. Smoke inhalation injury. Anesthetized female Yorkshire pigs (n = 33) inhaled room-temperature pine-bark smoke. Before injury, the pigs were randomized to receive conventional mechanical ventilation (n = 15) or airway pressure release ventilation (n = 12) for 48 hrs after smoke inhalation. As acute respiratory distress syndrome developed (PaO2/Fio2 ratio conventional mechanical ventilation for 48 hrs and served as time controls. Changes in PaO2/Fio2 ratio, tidal volume, respiratory rate, mean airway pressure, plateau pressure, and hemodynamic variables were recorded. Survival was assessed using Kaplan-Meier analysis. PaO2/Fio2 ratio was lower in airway pressure release ventilation vs. conventional mechanical ventilation pigs at 12, 18, and 24 hrs (p conventional mechanical ventilation animals between 30 and 48 hrs post injury (p animals between 6 and 48 hrs (p conventional mechanical ventilation and airway pressure release ventilation pigs. In this model of acute respiratory distress syndrome caused by severe smoke inhalation in swine, airway pressure release ventilation-treated animals developed acute respiratory distress syndrome faster than conventional mechanical ventilation-treated animals, showing a lower PaO2/Fio2 ratio at 12, 18, and 24 hrs after injury. At other time points, PaO2/Fio2 ratio was not different between conventional mechanical ventilation and airway pressure release ventilation.

  15. Work of breathing as a tool to diagnose severe fixed upper airway obstruction.

    Science.gov (United States)

    Khirani, S; Pierrot, S; Leboulanger, N; Ramirez, A; Breton, D; Couloigner, V; Fauroux, B

    2014-03-01

    A 4-year-old girl with bilateral vocal fold palsy was successfully decannulated from tracheotomy after seven laryngeal procedures. But an important stridor and dyspnea recurred 13 months after decannulation. Nocturnal gas exchange was normal but her daytime work of breathing was increased by fourfold, without any beneficial effect of nasal noninvasive continuous positive airway pressure ventilation (CPAP), reflecting a severe fixed airway obstruction. Endoscopic examination confirmed the work of breathing findings showing glottic and supraglottic stenosis. This upper airway obstruction was successfully treated with a recannulation. In conclusion, the major message of this case report is that measurement of the work of breathing was able to document the "fixed" nature of the airway obstruction, by showing no improvement even with highest tolerated levels of nasal CPAP. As such, the work of breathing may be proposed as a screening tool to quantify and assess the reversibility of severe upper airway obstruction in children. © 2013 Wiley Periodicals, Inc.

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway ... Positive Expiratory Pressure High-Frequency Chest Wall Oscillation (the Vest) Follow ...

  17. Low flow anesthesia: Efficacy and outcome of laryngeal mask airway versus pressure-optimized cuffed-endotracheal tube

    Directory of Open Access Journals (Sweden)

    El-Seify Zeinab

    2010-01-01

    Full Text Available Background: Low flow anesthesia can lead to reduction of anesthetic gas and vapor consumption. Laryngeal mask airway (LMA has proved to be an effective and safe airway device. The aim of this study is to assess the feasibility of laryngeal mask airway during controlled ventilation using low fresh gas flow (1.0 L/min as compared to endotracheal tube (ETT. Patients and Methods : Fifty nine non-smoking adult patients; ASA I or II, being scheduled for elective surgical procedures, with an expected duration of anesthesia 60 minutes or more, were randomly allocated into two groups - Group I (29 patients had been ventilated using LMA size 4 for females and 5 for males respectively; and Group II (30 patients were intubated using ETT. After 10 minutes of high fresh gas flow, the flow was reduced to 1 L/min. Patients were monitored for airway leakage, end-tidal CO 2 (ETCO 2 , inspiratory and expiratory isoflurane and nitrous oxide fraction concentrations, and postoperative airway-related complications Results : Two patients in the LMA-group developed initial airway leakage (6.9% versus no patient in ETT-group. Cough and sore throat were significantly higher in ETT patients. There were no evidences of differences between both groups regarding ETCO 2 , uptake of gases, nor difficulty in swallowing. Conclusion : The laryngeal mask airway proved to be effective and safe in establishing an airtight seal during controlled ventilation under low fresh gas flow of 1 L/min, inducing less coughing and sore throat during the immediate postoperative period than did the ETT, with continuous measurement and readjustment of the tube cuff pressure.

  18. Oral health in patients treated by positive airway pressure for obstructive sleep apnea: a population-based case-control study.

    Science.gov (United States)

    Carra, M C; Thomas, F; Schmitt, A; Pannier, B; Danchin, N; Bouchard, Ph

    2016-03-01

    Recent epidemiological evidence suggests that patients with obstructive sleep apnea (OSA) have an increased risk of periodontal disease. Little is known about the oral health of OSA patients treated by continuous or bi-level positive airway pressure (CPAP/BiPAP). The aim of this population-based case-control study was to compare oral health variables (amount of plaque, calculus, gingival inflammation, and masticatory function) between CPAP/BiPAP users and control subjects. The study population was retrieved from a French cohort examined between 2012 and 2013 at the Centre d'Investigations Préventives et Cliniques of Paris. Cases were selected if they reported to be treated by CPAP/BiPAP; controls were age-, gender-, and BMI-matched based on a 1:2 ratio. Univariate and logistic regression analyses were performed for group comparisons. Over a total of 20,436 subjects, 287 CPAP/BiPAP users (mean age (SD) 57.6 years (11.5); 76.3 % males) who underwent medical and dental examinations were compared with 574 matched controls (no OSA, no CPAP/BiPAP). CPAP/BiPAP users reported significantly higher prevalence of diabetes (15.6 vs. 10.3 %; p = 0.012; odds ratio (OR) 1.68), history of hypertension (36.5 vs. 26.1 %; p = 0.003; OR 1.62), cardiovascular diseases (14.1 vs. 8.8 %; p = 0.029; OR 1.69), and sleep complaints (59 vs. 34.4 %; p = 0.0001; OR 2.75). CPAP/BiPAP users also showed higher levels of depression and stress compared to controls. However, no group difference was observed for the amount of dental plaque, calculus, gingival inflammation, and masticatory function. Oral health of OSA patients treated by CPAP/BiPAP is comparable to that of matched controls in terms of amount of plaque, gingival inflammation, and masticatory function.

  19. Gadolinium prevents high airway pressure-induced permeability increases in isolated rat lungs.

    Science.gov (United States)

    Parker, J C; Ivey, C L; Tucker, J A

    1998-04-01

    To determine the initial signaling event in the vascular permeability increase after high airway pressure injury, we compared groups of lungs ventilated at different peak inflation pressures (PIPs) with (gadolinium group) and without (control group) infusion of 20 microM gadolinium chloride, an inhibitor of endothelial stretch-activated cation channels. Microvascular permeability was assessed by using the capillary filtration coefficient (Kfc), a measure of capillary hydraulic conductivity. Kfc was measured after ventilation for 30-min periods with 7, 20, and 30 cmH2O PIP with 3 cmH2O positive end-expiratory pressure and with 35 cmH2O PIP with 8 cmH2O positive end-expiratory pressure. In control lungs, Kfc increased significantly to 1.8 and 3.7 times baseline after 30 and 35 cmH2O PIP, respectively. In the gadolinium group, Kfc was unchanged from baseline (0.060 +/- 0.010 ml . min-1 . cmH2O-1 . 100 g-1) after any PIP ventilation period. Pulmonary vascular resistance increased significantly from baseline in both groups before the last Kfc measurement but was not different between groups. These results suggest that microvascular permeability is actively modulated by a cellular response to mechanical injury and that stretch-activated cation channels may initiate this response through increases in intracellular calcium concentration.

  20. Paradoxical reaction of blood pressure on sleep apnoea patients treated with Positive Airway Pressure

    Directory of Open Access Journals (Sweden)

    C. Chaves Loureiro

    2011-03-01

    Full Text Available Introduction: Obstructive Sleep Apnoea Syndrome (OSAS patients may develop hypertension and Positive Airway Pressure (PAP is an effective treatment in blood pressure (BP control. Objectives: Analyse a hypertensive OSAS population with unexpected BP rise after PAP usage and verify correlations between BP rise, either with OSAS severity index or nocturnal ventilatory support compliance. Methods: Descriptive, retrospective analysis of 30 patients with PAP treated OSA, for one year, on average, and with previous controlled hypertension, who developed a rise in BP, defined as augmentation of > 5 mmHg in systolic (SBP and/or diastolic BP (DBP, after PAP usage. Co-relational analysis of BP increase, with OSAS severity indexes and therapy compliance, using Pearson coefficient. Results: Of 508 consecutive patients followed in our Department, treated with nocturnal ventilatory support, 30 evolved with BP rise after initiating treatment (age 58 ± 10.8 years; Apnoea-Hypopnoea Index [AHI], 46.1 ± 18.68. After PAP usage, mean blood pressure (MBP, Systolic BP (SBP and Diastolic BP (DBP variation was 16 ± 15 mmHg, 20 ± 25 mmHg and 6 ± 19.4 mmHg, respectively. No patient showed significant BMI increase. Epworth Sleepiness Scale (ESS value decreased 8.9 ± 5.48 points. MBP, SBP and DBP variations were not correlated with P90/P95, residual AHI, leaks or PAP compliance. Conclusions: No specific characteristics were identified in the group who developed a rise in BP with PAP usage. No correlations were found between rises in BP and OSAS severity indexes or PAP compliance. Neither BMI nor variation in wakefulness status explained the rise in BP. Studies relate polymorphisms of b1-adrenoreceptors with different BP responses to ventilatory support. More studies are needed to clarify the cause of this paradoxical response. Resumo: Introdução: Doentes com síndrome de Apneia Obstrutiva do Sono (SAOS podem desenvolver hipertensão arterial (HTA sendo a

  1. Supra-Epiglottic Upper Airway Volume in Elderly Patients with Obstructive Sleep Apnea Hypopnea Syndrome.

    Science.gov (United States)

    Boutet, Claire; Abdirahman Mohamed Moussa, Syad; Celle, Sébastien; Laurent, Bernard; Barthélémy, Jean-Claude; Barral, Fabrice-Guy; Roche, Frédéric

    2016-01-01

    Small upper airway measurements areas and high body mass index are recognized risk factors for obstructive sleep apnea syndrome (OSAS) in non-elderly populations; however, there is limited information regarding elderly patients. We evaluated whether upper airway volume is associated with OSAS and OSAS treated with continuous positive airway pressure (CPAP) treatment and whether BMI is correlated with upper airway volume and measurements in elderly subjects. In 60 volunteers aged 75.58±0.9 years: 20 OSAS, 20 OSAS chronically treated with CPAP, and 20 controls, semi-automatic segmentation, retropalatal distance and transverse diameter of the supra-epiglottic upper airway were evaluated using 3DT1-weighted magnetic resonance imaging. Anteroposterior to transverse diameter ratio was defined as retropalatar diameter/transverse diameter. There were no significant differences in supra-epiglottic upper airway volume between OSAS, CPAP treated patients, and controls. There were significant differences in retropalatal distance and anteroposterior to transverse diameter ratio between OSAS, CPAP treated patients, and controls (P = 0.008 and Psupra-epiglottic upper airway volume. In elderly subjects, OSAS and body mass index are not associated with changes in supra-epiglottic upper airway volume but are associated with modification of pharynx shape.

  2. Heated, Humidified High-Flow Nasal Cannula vs Nasal Continuous Positive Airway Pressure for Respiratory Distress Syndrome of Prematurity: A Randomized Clinical Noninferiority Trial.

    Science.gov (United States)

    Lavizzari, Anna; Colnaghi, Mariarosa; Ciuffini, Francesca; Veneroni, Chiara; Musumeci, Stefano; Cortinovis, Ivan; Mosca, Fabio

    2016-08-08

    Heated, humidified high-flow nasal cannula (HHHFNC) has gained increasing popularity as respiratory support for newborn infants thanks to ease of use and improved patient comfort. However, its role as primary therapy for respiratory distress syndrome (RDS) of prematurity needs to be further elucidated by large, randomized clinical trials. To determine whether HHHFNC provides respiratory support noninferior to nasal continuous positive airway pressure (nCPAP) or bilevel nCPAP (BiPAP) as a primary approach to RDS in infants older than 28 weeks' gestational age (GA). An unblinded, monocentric, randomized clinical noninferiority trial at a tertiary neonatal intensive care unit. Inborn infants at 29 weeks 0 days to 36 weeks 6 days of GA were eligible if presenting with mild to moderate RDS requiring noninvasive respiratory support. Criteria for starting noninvasive respiratory support were a Silverman score of 5 or higher or a fraction of inspired oxygen higher than 0.3 for a target saturation of peripheral oxygen of 88% to 93%. Infants were ineligible if they had major congenital anomalies or severe RDS requiring early intubation. Infants were enrolled between January 5, 2012, and June 28, 2014. Randomization to either HHHFNC at 4 to 6 L/min or nCPAP/BiPAP at 4 to 6 cm H2O. Need for mechanical ventilation within 72 hours from the beginning of respiratory support. The absolute risk difference in the primary outcome and its 95% confidence interval were calculated to determine noninferiority (noninferiority margin, 10%). An intention-to-treat analysis was performed. A total of 316 infants were enrolled in the study: 158 in the HHHFNC group (mean [SD] GA, 33.1 [1.9] weeks; 52.5% female) and 158 in the nCPAP/BiPAP group (mean [SD] GA, 33.0 [2.1] weeks; 47.5% female). The use of HHHFNC was noninferior to nCPAP with regard to the primary outcome: failure occurred in 10.8% vs 9.5% of infants, respectively (95% CI of risk difference, -6.0% to 8.6% [within the noninferiority

  3. Alternatives for OSAHS treatment: selection of patients for upper airway surgery and oral appliances

    Directory of Open Access Journals (Sweden)

    A. Boudewyns

    2007-12-01

    Full Text Available Although continuous positive airway pressure (CPAP is considered to represent the standard treatment for patients with moderate-to-severe obstructive sleep apnoea/hypopnoea syndrome (OSAHS, poor treatment compliance and/or refusal is an issue in 20–30% of these patients. As an alternative to life-long CPAP treatment, conservative procedures exist with dental appliances for mandibular advancement, as well as curative surgical techniques. Surgical treatment of OSAHS can be divided into the following two main groups: 1 upper airway surgery by soft tissue resection (uvulopalatopharyngoplasty, etc., and 2 skeletal procedures, such as maxillo-mandibular advancement. Proper selection of patients for the different treatment modalities is the key for full treatment success. Patient-related factors, such as the site of upper airway collapse, craniofacial characteristics, dental health, obesity, age, profession and positional dependence, as well as treatment-related factors, should be evaluated before a final proposal for these treatment alternatives is formulated.

  4. Effects of positive airway pressure therapy on cardiovascular and metabolic markers in males with obstructive sleep apnea.

    Science.gov (United States)

    Feliciano, A; Oliveira, M J; Cysneiros, A; Martinho, C; Reis, R P; Penque, D; Pinto, P; Bárbara, C

    Obstructive sleep apnea syndrome (OSAS) is associated with cardiovascular/metabolic complications. Some analytical parameters (homocysteine, glycemic and lipidic profiles) are recognized markers of these consequences. Limited data is available on the association of these markers and OSAS's severity/response to positive airway pressure therapy (PAP). In this prospective study we analyzed polysomnographic and analytical data of male patients admitted to sleep laboratory. The aim was to evaluate metabolic/cardiovascular markers in snorers and OSAS patients, to relate with sleep parameters and PAP response. One-hundred and three patients were included, and 73 (71%) were OSAS patients. OSAS patients were similar to snorers except for higher body mass index (BMI) and dyslipidemia. Severe OSAS patients showed higher glycemia, HbA1c, insulin, and insulin resistance, and lower HDL cholesterol in comparison to mild-moderate (pprofile and triglycerides were slightly correlated with OSAS severity. 46 OSAS patients were submitted to 6 months of PAP, with a statistical decrease in mean values of homocysteine, glycemia, total and LDL cholesterol (pprofiles changed significantly after 6 months of PAP therapy in OSAS, supporting its cardiovascular and metabolic protective effect. Our study has reinforced the importance of analytical cardiovascular/metabolic evaluation as complementary tool of diagnosis/treatment response in OSAS. Copyright © 2017 Sociedade Portuguesa de Pneumologia. Published by Elsevier España, S.L.U. All rights reserved.

  5. Dynamic airway pressure-time curve profile (Stress Index): a systematic review.

    Science.gov (United States)

    Terragni, Pierpaolo; Bussone, Guido; Mascia, Luciana

    2016-01-01

    The assessment of respiratory mechanics at the bedside is necessary in order to identify the most protective ventilatory strategy. Indeed in the last 20 years, adverse effects of positive ventilation to the lung structures have led to a reappraisal of the objectives of mechanical ventilation. The ventilator setting requires repeated readjustment over the period of mechanical ventilation dependency and careful respiratory monitoring to minimize the risks, preventing further injury and permitting the lung and airways healing. Among the different methods that have been proposed and validated, the analysis of dynamic P-t curve (named Stress Index, SI) represents an adequate tool available at the bedside, repeatable and, therefore, able to identify the amount of overdistension occurring in the daily clinical practice, when modifying positive end-expiratory pressure. In this review we will analyze the evidence that supports respiratory mechanics assessment at the bedside and the application of the dynamic P/t curve profile (SI) to optimize protective ventilation in patients with acute respiratory failure.

  6. In vitro surfactant and perfluorocarbon aerosol deposition in a neonatal physical model of the upper conducting airways.

    Directory of Open Access Journals (Sweden)

    Estibalitz Goikoetxea

    Full Text Available OBJECTIVE: Aerosol delivery holds potential to release surfactant or perfluorocarbon (PFC to the lungs of neonates with respiratory distress syndrome with minimal airway manipulation. Nevertheless, lung deposition in neonates tends to be very low due to extremely low lung volumes, narrow airways and high respiratory rates. In the present study, the feasibility of enhancing lung deposition by intracorporeal delivery of aerosols was investigated using a physical model of neonatal conducting airways. METHODS: The main characteristics of the surfactant and PFC aerosols produced by a nebulization system, including the distal air pressure and air flow rate, liquid flow rate and mass median aerodynamic diameter (MMAD, were measured at different driving pressures (4-7 bar. Then, a three-dimensional model of the upper conducting airways of a neonate was manufactured by rapid prototyping and a deposition study was conducted. RESULTS: The nebulization system produced relatively large amounts of aerosol ranging between 0.3±0.0 ml/min for surfactant at a driving pressure of 4 bar, and 2.0±0.1 ml/min for distilled water (H2Od at 6 bar, with MMADs between 2.61±0.1 µm for PFD at 7 bar and 10.18±0.4 µm for FC-75 at 6 bar. The deposition study showed that for surfactant and H2Od aerosols, the highest percentage of the aerosolized mass (∼65% was collected beyond the third generation of branching in the airway model. The use of this delivery system in combination with continuous positive airway pressure set at 5 cmH2O only increased total airway pressure by 1.59 cmH2O at the highest driving pressure (7 bar. CONCLUSION: This aerosol generating system has the potential to deliver relatively large amounts of surfactant and PFC beyond the third generation of branching in a neonatal airway model with minimal alteration of pre-set respiratory support.

  7. Unidirectional Expiratory Valve Method to Assess Maximal Inspiratory Pressure in Individuals without Artificial Airway.

    Directory of Open Access Journals (Sweden)

    Samantha Torres Grams

    Full Text Available Maximal Inspiratory Pressure (MIP is considered an effective method to estimate strength of inspiratory muscles, but still leads to false positive diagnosis. Although MIP assessment with unidirectional expiratory valve method has been used in patients undergoing mechanical ventilation, no previous studies investigated the application of this method in subjects without artificial airway.This study aimed to compare the MIP values assessed by standard method (MIPsta and by unidirectional expiratory valve method (MIPuni in subjects with spontaneous breathing without artificial airway. MIPuni reproducibility was also evaluated.This was a crossover design study, and 31 subjects performed MIPsta and MIPuni in a random order. MIPsta measured MIP maintaining negative pressure for at least one second after forceful expiration. MIPuni evaluated MIP using a unidirectional expiratory valve attached to a face mask and was conducted by two evaluators (A and B at two moments (Tests 1 and 2 to determine interobserver and intraobserver reproducibility of MIP values. Intraclass correlation coefficient (ICC[2,1] was used to determine intraobserver and interobserver reproducibility.The mean values for MIPuni were 14.3% higher (-117.3 ± 24.8 cmH2O than the mean values for MIPsta (-102.5 ± 23.9 cmH2O (p<0.001. Interobserver reproducibility assessment showed very high correlation for Test 1 (ICC[2,1] = 0.91, and high correlation for Test 2 (ICC[2,1] = 0.88. The assessment of the intraobserver reproducibility showed high correlation for evaluator A (ICC[2,1] = 0.86 and evaluator B (ICC[2,1] = 0.77.MIPuni presented higher values when compared with MIPsta and proved to be reproducible in subjects with spontaneous breathing without artificial airway.

  8. Upper airway finding on CT scan with and without nasal CPAP in obstructive sleep apnea patients

    International Nuclear Information System (INIS)

    Akashiba, Tsuneto; Sasaki, Iwao; Kurashina, Keiji; Yoshizawa, Takayuki; Otsuka, Kenzo; Horie, Takashi

    1991-01-01

    The area of upper airway (from the nasopharynx to the hypopharynx) was measured by means of computed tomography (CT) scan in 15 confirmed cases of obstructive sleep apnea (OSA) and in 4 normal controls while they were awake. The minimum cross-sectional area (MA) of the upper airway was 14.7±20.0 mm 2 in OSA patients and 80.0±33.1 mm 2 in normal controls and the difference was statistically significant (p 2 and lowest SO 2 . MA was also measured with OSA patients while nasal continuous positive airway pressure (NCPAP) of 10 cmH 2 O was applied and it was found that MA was significantly widened when NCPAP therapy was performed. We conclude that upper airway narrowing is consistent finding in OSA patients but the degree of narrowing does not correlate with parameters of apnea and gas exchange during sleep, and NCPAP is effective to widen the area of upper airway in OSA patients. (author)

  9. Prevalence and variability of use of home mechanical ventilators, positive airway pressure and oxygen devices in the Lombardy region, Italy.

    Science.gov (United States)

    Vitacca, Michele; Barbano, Luca; Colombo, Daniele; Leoni, Olivia; Guffanti, Enrico

    2018-01-29

    Few studies have analyzed the prevalence and accessibility of home mechanical ventilation (HMV) in Italy. We aimed to investigate the prevalence and prescription variability of HMV as well as of long-term oxygen therapy (LTOT) and continuous positive airway pressure (CPAP), in the Lombardy Region. Prescribing rates of HMV (both noninvasive and tracheostomies), CPAP (auto-CPAP, CPAP/other sleep machines) and LTOT (liquid-O2, O2-gas, concentrators) in the 15 Local Healthcare districts of Lombardy were gathered from billing data for 2012 and compared. Crude rates (per 100,000 population) and rates for the different healthcare districts were calculated. In 2012, 6325 patients were on HMV (crude prescription rate: 63/100,000) with a high variation across districts (8/100,000 in Milano 1 vs 150/100,000 in Pavia). There were 14,237 patients on CPAP (crude prescription rate: 142/100,000; CPAP/other sleep machines 95.3% vs auto-CPAP 4.7%) with also high intra-regional variation (56/100,000 in Mantova vs. 260/100,000 in Pavia). There were 21,826 patients on LTOT (prescription rate: 217/100,000 rate; liquid-O2 94%, O2-gas 2.08%, O2-concentrators 3.8%), with again high intra-regional variation (100/100,000 in Bergamo vs 410/100,000 in Valle Camonica). The crude rate of HMV prescriptions in Lombardy is very high, with a high intra-regional variability in prescribing HMV, LTOT and CPAP which is partly explainable by the accessibility to specialist centers with HMV/sleep-study facilities. Analysis of administrative data and variability mapping can help identify areas of reduced access for an improved standardization of services. An audit among Health Payer and prescribers to interpret the described huge variability could be welcomed.

  10. Infant flow biphasic nasal continuous positive airway pressure (BP- NCPAP vs. infant flow NCPAP for the facilitation of extubation in infants' ≤ 1,250 grams: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    O'Brien Karel

    2012-04-01

    Full Text Available Abstract Background The use of mechanical ventilation is associated with lung injury in preterm infants and therefore the goal is to avoid or minimize its use. To date there is very little consensus on what is considered the "best non-invasive ventilation mode" to be used post-extubation. The objective of this study was to compare the effectiveness of biphasic nasal continuous positive airway pressure (BP-NCPAP vs. NCPAP in facilitating sustained extubation in infants ≤ 1,250 grams. Methods We performed a randomized controlled trial of BP-NCPAP vs. NCPAP in infants ≤ 1,250 grams extubated for the first time following mechanical ventilation since birth. Infants were extubated using preset criteria or at the discretion of the attending neonatologist. The primary outcome was the incidence of sustained extubation for 7 days. Secondary outcomes included incidence of adverse events and short-term neonatal outcomes. Results Sixty-seven infants received BP-NCPAP and 69 NCPAP. Baseline characteristics were similar between groups. The trial was stopped early due to increased use of non-invasive ventilation from birth, falling short of our calculated sample size of 141 infants per group. The incidence of sustained extubation was not statistically different between the BP-NCPAP vs. NCPAP group (67% vs. 58%, P = 0.27. The incidence of adverse events and short-term neonatal outcomes were similar between the two groups (P > 0.05 except for retinopathy of prematurity which was noted to be higher (P = 0.02 in the BP-NCPAP group. Conclusions Biphasic NCPAP may be used to assist in weaning from mechanical ventilation. The effectiveness and safety of BP-NCPAP compared to NCPAP needs to be confirmed in a large multi-center trial as our study conclusions are limited by inadequate sample size. Clinical Trials Registration # NCT00308789 Source of support Grant # 06-06, Physicians Services Incorporated Foundation, Toronto, Canada. Summit technologies Inc. provided

  11. Nebulized hypertonic saline via positive expiratory pressure versus via jet nebulizer in patients with severe cystic fibrosis.

    LENUS (Irish Health Repository)

    O'Connell, Oisin J

    2011-06-01

    Nebulized hypertonic saline is a highly effective therapy for patients with cystic fibrosis (CF), yet 10% of patients are intolerant of hypertonic saline administered via jet nebulizer. Positive expiratory pressure (PEP) nebulizers splint open the airways and offers a more controlled rate of nebulization.

  12. Adaptação do Bird Mark 7 para oferta de pressão positiva contínua nas vias aéreas em ventilação não-invasiva: estudo em modelo mecânico Adapting the Bird Mark 7 to deliver noninvasive continuous positive airway pressure: a bench study

    Directory of Open Access Journals (Sweden)

    Beatriz Mayumi Kikuti

    2008-03-01

    Full Text Available OBJETIVO: Testar a eficiência da adaptação do ventilador Bird Mark 7 para oferecer pressão positiva contínua nas vias aéreas, conhecida como continuous positive airway pressure (CPAP em inglês, em ventilação não-invasiva. MÉTODOS: Estudo experimental utilizando um modelo mecânico do sistema respiratório. O Bird Mark 7 foi alimentado com 400 e 500 kPa e foi testado em CPAP de 5, 10 e 15 cmH2O. Para avaliar a eficiência da adaptação foram analisados os seguintes variáveis: diferença entre a CPAP pré-determinada e a CPAP realmente atingida (CPAPreal; área da pressão da via aérea sob o nível de CPAP ajustado (ÁREA CPAP; e volume corrente gerado. RESULTADOS: A adaptação do Bird Mark 7 para oferecer CPAP em ventilação não-invasiva conseguiu atingir o volume corrente esperado em todas as situações de esforço inspiratório (normal ou elevado, pressão de alimentação (400 ou 500 kPa e valor de CPAP (5, 10 ou 15 cmH2O. Para os CPAPs de 5 e 10 cmH2O, o CPAPreal foi muito próximo do pré-determinado, e a ÁREA CPAP teve valor próximo de zero. Para o CPAP de 15 cmH2O, o CPAPreal ficou abaixo do pré-determinado, e a ÁREA CPAP teve valor elevado. CONCLUSÃO: A eficiência da adaptação do Bird Mark 7 para oferecer CPAP em ventilação não-invasiva foi boa para os valores de CPAP de 5 e 10 cmH2O e insuficiente para CPAP de 15 cmH2O. Se adaptado como em nosso estudo, o Bird Mark 7 pode ser uma opção para oferta de CPAP até 10 cmH2O em locais onde equipamentos de ventilação não-invasiva são escassos ou inexistentes.OBJECTIVE: To test the efficiency of the Bird Mark 7 ventilator adapted to deliver continuous positive airway pressure (CPAP in noninvasive positive pressure ventilation. METHODS: This was an experimental study using a mechanical model of the respiratory system. A Bird Mark 7 ventilator was supplied with 400 and 500 kPa and tested at CPAP of 5, 10 and 15 cmH2O. The following variables were analyzed

  13. Inhibitory Effect of Nasal Intermittent Positive Pressure Ventilation on Gastroesophageal Reflux.

    Directory of Open Access Journals (Sweden)

    Danny Cantin

    Full Text Available Non-invasive intermittent positive pressure ventilation can lead to esophageal insufflations and in turn to gastric distension. The fact that the latter induces transient relaxation of the lower esophageal sphincter implies that it may increase gastroesophageal refluxes. We previously reported that nasal Pressure Support Ventilation (nPSV, contrary to nasal Neurally-Adjusted Ventilatory Assist (nNAVA, triggers active inspiratory laryngeal closure. This suggests that esophageal insufflations are more frequent in nPSV than in nNAVA. The objectives of the present study were to test the hypotheses that: i gastroesophageal refluxes are increased during nPSV compared to both control condition and nNAVA; ii esophageal insufflations occur more frequently during nPSV than nNAVA. Polysomnographic recordings and esophageal multichannel intraluminal impedance pHmetry were performed in nine chronically instrumented newborn lambs to study gastroesophageal refluxes, esophageal insufflations, states of alertness, laryngeal closure and respiration. Recordings were repeated without sedation in control condition, nPSV (15/4 cmH2O and nNAVA (~ 15/4 cmH2O. The number of gastroesophageal refluxes recorded over six hours, expressed as median (interquartile range, decreased during both nPSV (1 (0, 3 and nNAVA [1 (0, 3] compared to control condition (5 (3, 10, (p < 0.05. Meanwhile, the esophageal insufflation index did not differ between nPSV (40 (11, 61 h-1 and nNAVA (10 (9, 56 h-1 (p = 0.8. In conclusion, nPSV and nNAVA similarly inhibit gastroesophageal refluxes in healthy newborn lambs at pressures that do not lead to gastric distension. In addition, the occurrence of esophageal insufflations is not significantly different between nPSV and nNAVA. The strong inhibitory effect of nIPPV on gastroesophageal refluxes appears identical to that reported with nasal continuous positive airway pressure.

  14. Continuous Positive Airway Pressure (CPAP for prevention of recurrent pneumonia in the Neuromyelitis Optica patient

    Directory of Open Access Journals (Sweden)

    James A. Welker

    2014-01-01

    Conclusions: Patients with Neuromyelitis Optica differ from those with traumatic spinal cord injury as they have a chronic progressive systemic illness that causes continued deterioration of their nervous system resulting in the need for routine monitoring that ensures the timely addition of CPAP for the prevention of pneumonia and its associated medical expenses.

  15. Control of positive end-expiratory pressure (PEEP for small animal ventilators

    Directory of Open Access Journals (Sweden)

    Leão Nunes Marcelo V

    2010-07-01

    Full Text Available Abstract Background The positive end-expiratory pressure (PEEP for the mechanical ventilation of small animals is frequently obtained with water seals or by using ventilators developed for human use. An alternative mechanism is the use of an on-off expiratory valve closing at the moment when the alveolar pressure is equal to the target PEEP. In this paper, a novel PEEP controller (PEEP-new and the PEEP system of a commercial small-animal ventilator, both based on switching an on-off valve, are evaluated. Methods The proposed PEEP controller is a discrete integrator monitoring the error between the target PEEP and the airways opening pressure prior to the onset of an inspiratory cycle. In vitro as well as in vivo experiments with rats were carried out and the PEEP accuracy, settling time and under/overshoot were considered as a measure of performance. Results The commercial PEEP controller did not pass the tests since it ignores the airways resistive pressure drop, resulting in a PEEP 5 cmH2O greater than the target in most conditions. The PEEP-new presented steady-state errors smaller than 0.5 cmH2O, with settling times below 10 s and under/overshoot smaller than 2 cmH2O. Conclusion The PEEP-new presented acceptable performance, considering accuracy and temporal response. This novel PEEP generator may prove useful in many applications for small animal ventilators.

  16. Clinical assessment of auto-positive end-expiratory pressure by diaphragmatic electrical activity during pressure support and neurally adjusted ventilatory assist.

    Science.gov (United States)

    Bellani, Giacomo; Coppadoro, Andrea; Patroniti, Nicolò; Turella, Marta; Arrigoni Marocco, Stefano; Grasselli, Giacomo; Mauri, Tommaso; Pesenti, Antonio

    2014-09-01

    Auto-positive end-expiratory pressure (auto-PEEP) may substantially increase the inspiratory effort during assisted mechanical ventilation. Purpose of this study was to assess whether the electrical activity of the diaphragm (EAdi) signal can be reliably used to estimate auto-PEEP in patients undergoing pressure support ventilation and neurally adjusted ventilatory assist (NAVA) and whether NAVA was beneficial in comparison with pressure support ventilation in patients affected by auto-PEEP. In 10 patients with a clinical suspicion of auto-PEEP, the authors simultaneously recorded EAdi, airway, esophageal pressure, and flow during pressure support and NAVA, whereas external PEEP was increased from 2 to 14 cm H2O. Tracings were analyzed to measure apparent "dynamic" auto-PEEP (decrease in esophageal pressure to generate inspiratory flow), auto-EAdi (EAdi value at the onset of inspiratory flow), and IDEAdi (inspiratory delay between the onset of EAdi and the inspiratory flow). The pressure necessary to overcome auto-PEEP, auto-EAdi, and IDEAdi was significantly lower in NAVA as compared with pressure support ventilation, decreased with increase in external PEEP, although the effect of external PEEP was less pronounced in NAVA. Both auto-EAdi and IDEAdi were tightly correlated with auto-PEEP (r = 0.94 and r = 0.75, respectively). In the presence of auto-PEEP at lower external PEEP levels, NAVA was characterized by a characteristic shape of the airway pressure. In patients with auto-PEEP, NAVA, compared with pressure support ventilation, led to a decrease in the pressure necessary to overcome auto-PEEP, which could be reliably monitored by the electrical activity of the diaphragm before inspiratory flow onset (auto-EAdi).

  17. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    Directory of Open Access Journals (Sweden)

    Thomas Berlet

    2016-01-01

    Full Text Available This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema.

  18. Effects of short-term pressure-controlled ventilation on gas exchange, airway pressures, and gas distribution in patients with acute lung injury/ARDS: comparison with volume-controlled ventilation.

    Science.gov (United States)

    Prella, Maura; Feihl, François; Domenighetti, Guido

    2002-10-01

    The potential clinical benefits of pressure-controlled ventilation (PCV) over volume-controlled ventilation (VCV) in patients with acute lung injury (ALI) or ARDS still remain debated. We compared PCV with VCV in patients with ALI/ARDS with respect to the following physiologic end points: (1) gas exchange and airway pressures, and (2) CT scan intrapulmonary gas distribution at end-expiration. Prospective, observational study. A multidisciplinary ICU in a nonuniversity, acute-care hospital. Ten patients with ALI or ARDS (9 men and 1 woman; age range, 17 to 80 years). Sequential ventilation in PCV and VCV with a constant inspiratory/expiratory ratio, tidal volume, respiratory rate, and total positive end-expiratory pressure; measurement of gas exchange and airway pressures; and achievement of CT sections at lung base, hilum, and apex for the quantitative analysis of lung densities and of aerated vs nonaerated zones. PaO(2), PaCO(2), and PaO(2)/fraction of inspired oxygen ratio levels did not differ between PCV and VCV. Peak airway pressure (Ppeak) was significantly lower in PCV compared with VCV (26 +/- 2 cm H(2)O vs 31 +/- 2 cm H(2)O; p mean +/- SEM). The surface areas of the nonaerated zones as well as the total areas at each section level were unchanged in PCV compared with VCV, except at the apex level, where there was a significantly greater nonaerated area in VCV (11 +/- 2 cm(2) vs 9 +/- 2 cm(2); p mean CT number of each lung (20 lungs from 10 patients) was similar in the two modes, as were the density values at the basal and apical levels; the hilum mean CT number was - 442 +/- 28 Hounsfield units (HU) in VCV and - 430 +/- 26 HU in PCV (p lower Ppeaks through the precise titration of the lung distending pressure, and might be applied to avoid regional overdistension by means of a more homogeneous gas distribution.

  19. [Effectiveness of nasal positive pressure ventilation in the management of acute refractory left ventricular insufficiency].

    Science.gov (United States)

    Chesi, G; Pinelli, G; Galimberti, D; Navazio, A; Montanari, P

    1994-04-01

    Ehen refractory to optimal medical treatment cardiogenic pulmonary edema requires mechanical ventilation as a last therapeutic resource. In recent years an increasing number of authors reported their experience in the management of acute or subacute respiratory failure with non-invasive mechanical ventilation by nasal mask. Encouraged by the first promising results reported in literature we experimented this new therapeutic tool in a first group of seven elderly patients (mean age: 76.57--range: 65-89); they all had been admitted for severe cardiogenic pulmonary edema unresponsive to maximal doses of the conventional drugs available for treating acute decompensated heart failure. The enrolled patients were treated with intermittent ventilation administered by nasal mask at selected values of inspiratory positive airway pressure (IPAP) that were comprised between 10 and 20 cm H2O. At the same time an expiratory positive airway pressure (EPAP) at values comprised between 3 and 8 cm H2O was applied. Ventilation was continued for variable periods of 3-24 hours until acceptable values of PaO2 and PaCO2 were obtained. The ventilation modality was spontaneous, spontaneous-time or timed depending on the patients' level of consciousness at starting time. A good short-term outcome was achieved in all the patients regardless of the ventilation modality applied. The main blood gas alteration was severe hypercapnia with acidosis in three patients, while the other four presented critical hypoxemia unresponsive to simple oxygen supply even if delivered by high-flow Venturi mask. Four of our seven patients were discharged from hospital in satisfactory haemodynamic conditions; the remaining three died during hospitalization from refractory heart failure. In this our preliminary experience the therapeutic approach with nasal positive pressure ventilation (NPPV) and EPAP proved to be very effective to improve the signs and symptoms of acute refractory cardiogenic pulmonary edema as

  20. Dangerous Pressurization and Inappropriate Alarms during Water Occlusion of the Expiratory Circuit of Commonly Used Infant Ventilators.

    Directory of Open Access Journals (Sweden)

    Murray Hinder

    Full Text Available Non-invasive continuous positive airways pressure is commonly a primary respiratory therapy delivered via multi-purpose ventilators in premature newborns. Expiratory limb occlusion due to water accumulation or 'rainout' from gas humidification is a frequent issue. A case of expiratory limb occlusion due to rainout causing unexpected and excessive repetitive airway pressurisation in a Draeger VN500 prompted a systematic bench test examination of currently available ventilators.To assess neonatal ventilator response to partial or complete expiratory limb occlusion when set to non-invasive continuous positive airway pressure mode.Seven commercially available neonatal ventilators connected to a test lung using a standard infant humidifier circuit with partial and/or complete expiratory limb occlusion were examined in a bench test study. Each ventilator was set to deliver 6 cmH2O in non-invasive mode and respiratory mechanics data for 75%, 80% and 100% occlusion were collected.Several ventilators responded inappropriately with complete occlusion by cyclical pressurisation/depressurisation to peak pressures of between 19·4 and 64·6 cm H2O at rates varying between 2 to 77 inflations per minute. Tidal volumes varied between 10·1 and 24·3mL. Alarm responses varied from 'specific' (tube occluded to 'ambiguous' (Safety valve open. Carefusion Avea responded by continuing to provide the set distending pressure and displaying an appropriate alarm message. Draeger Babylog 8000 did not alarm with partial occlusions and incorrectly displayed airways pressure at 6·1cmH2O compared to the measured values of 13cmH2O.This study found a potential for significant adverse ventilator response due to complete or near complete expiratory limb occlusion in CPAP mode.

  1. Continuing the Original Stanford Sleep Surgery Protocol From Upper Airway Reconstruction to Upper Airway Stimulation: Our First Successful Case.

    Science.gov (United States)

    Liu, Stanley Yung; Riley, Robert Wayne

    2017-07-01

    In 1993, a surgical protocol for dynamic upper airway reconstruction in patients with obstructive sleep apnea (OSA) was published, and it became commonly known as the Stanford phase 1 and 2 sleep surgery protocol. It served as a platform on which research and clinical studies have continued to perfect the surgical care of patients with OSA. However, relapse is inevitable in a chronic condition such as OSA, and a subset of previously cured surgical patients return with complaints of excessive daytime sleepiness. This report describes a patient who was successfully treated with phase 1 and 2 operations more than a decade previously. He returned at 65 years of age with relapse of moderate OSA, and after workup with polysomnography and drug-induced sleep endoscopy, he underwent upper airway stimulation of the hypoglossal nerve that resulted in a cure of OSA. This case shows why upper airway stimulation is an appropriate option for patients with OSA relapse, after previously successful maxillomandibular advancement. Copyright © 2017. Published by Elsevier Inc.

  2. Interaction between peri-operative blood transfusion, tidal volume, airway pressure and postoperative ARDS: an individual patient data meta-analysis.

    Science.gov (United States)

    Serpa Neto, Ary; Juffermans, Nicole P; Hemmes, Sabrine N T; Barbas, Carmen S V; Beiderlinden, Martin; Biehl, Michelle; Fernandez-Bustamante, Ana; Futier, Emmanuel; Gajic, Ognjen; Jaber, Samir; Kozian, Alf; Licker, Marc; Lin, Wen-Qian; Memtsoudis, Stavros G; Miranda, Dinis Reis; Moine, Pierre; Paparella, Domenico; Ranieri, Marco; Scavonetto, Federica; Schilling, Thomas; Selmo, Gabriele; Severgnini, Paolo; Sprung, Juraj; Sundar, Sugantha; Talmor, Daniel; Treschan, Tanja; Unzueta, Carmen; Weingarten, Toby N; Wolthuis, Esther K; Wrigge, Hermann; de Abreu, Marcelo Gama; Pelosi, Paolo; Schultz, Marcus J

    2018-01-01

    Transfusion of blood products and mechanical ventilation with injurious settings are considered risk factors for postoperative lung injury in surgical Patients. A systematic review and individual patient data meta-analysis was done to determine the independent effects of peri-operative transfusion of blood products, intra-operative tidal volume and airway pressure in adult patients undergoing mechanical ventilation for general surgery, as well as their interactions on the occurrence of postoperative acute respiratory distress syndrome (ARDS). Observational studies and randomized trials were identified by a systematic search of MEDLINE, CINAHL, Web of Science, and CENTRAL and screened for inclusion into a meta-analysis. Individual patient data were obtained from the corresponding authors. Patients were stratified according to whether they received transfusion in the peri-operative period [red blood cell concentrates (RBC) and/or fresh frozen plasma (FFP)], tidal volume size [≤7 mL/kg predicted body weight (PBW), 7-10 and >10 mL/kg PBW] and airway pressure level used during surgery (≤15, 15-20 and >20 cmH 2 O). The primary outcome was development of postoperative ARDS. Seventeen investigations were included (3,659 patients). Postoperative ARDS occurred in 40 (7.2%) patients who received at least one blood product compared to 40 patients (2.5%) who did not [adjusted hazard ratio (HR), 2.32; 95% confidence interval (CI), 1.25-4.33; P=0.008]. Incidence of postoperative ARDS was highest in patients ventilated with tidal volumes of >10 mL/kg PBW and having airway pressures of >20 cmH 2 O receiving both RBC and FFP, and lowest in patients ventilated with tidal volume of ≤7 mL/kg PBW and having airway pressures of ≤15 cmH 2 O with no transfusion. There was a significant interaction between transfusion and airway pressure level (P=0.002) on the risk of postoperative ARDS. Peri-operative transfusion of blood products is associated with an increased risk of

  3. Control of upper airway muscle activity in younger versus older men during sleep onset

    Science.gov (United States)

    Fogel, Robert B; White, David P; Pierce, Robert J; Malhotra, Atul; Edwards, Jill K; Dunai, Judy; Kleverlaan, Darci; Trinder, John

    2003-01-01

    Pharyngeal dilator muscles are clearly important in the pathophysiology of obstructive sleep apnoea syndrome (OSA). We have previously shown that the activity of both the genioglossus (GGEMG) and tensor palatini (TPEMG) are decreased at sleep onset, and that this decrement in muscle activity is greater in the apnoea patient than in healthy controls. We have also previously shown this decrement to be greater in older men when compared with younger ones. In order to explore the mechanisms responsible for this decrement in muscle activity nasal continuous positive airway pressure (CPAP) was applied to reduce negative pressure mediated muscle activation. We then investigated the effect of sleep onset (transition from predominantly α to predominantly θ EEG activity) on ventilation, upper airway muscle activation and upper airway resistance (UAR) in middle-aged and younger healthy men. We found that both GGEMG and TPEMG were reduced by the application of nasal CPAP during wakefulness, but that CPAP did not alter the decrement in activity in either muscle seen in the first two breaths following an α to θ transition. However, CPAP prevented both the rise in UAR at sleep onset that occurred on the control night, and the recruitment in GGEMG seen in the third to fifth breaths following the α to θ transition. Further, GGEMG was higher in the middle-aged men than in the younger men during wakefulness and was decreased more in the middle-aged men with the application of nasal CPAP. No differences were seen in TPEMG between the two age groups. These data suggest that the initial sleep onset reduction in upper airway muscle activity is due to loss of a ‘wakefulness’ stimulus, rather than to loss of responsiveness to negative pressure. In addition, it suggests that in older men, higher wakeful muscle activity is due to an anatomically more collapsible upper airway with more negative pressure driven muscle activation. Sleep onset per se does not appear to have a greater

  4. Management of Upper Airway Resistance Syndrome: A Systematic Literature Review

    Directory of Open Access Journals (Sweden)

    Ranjan Mathur

    2015-01-01

    Full Text Available Background : This disorder, also known by terms such as obstructive sleep apnea (OSA, upper airway sleep disorder and snoring. Snoring has also been identified as a possible risk factor for hyper tension, ischemic heart disease and stroke. The role of dentistry in sleep disorders is becoming more significant, especially in co- managing patients with simple snoring and mild to moderate OSA. The practicing dental professional has the opportunity to assist patients at a variety of levels, starting with the recognition of a sleep -related disorder, referring patients to a physician for evaluation and assisting in the management of sleep disorders. The first and simplest option would be behaviour modification, followed by insertion of oral devices suited to the patient, especially in those with mild to moderate OSA. Continuous positive airway pressure (CPAP and surgic al options are chosen for patients with moderate to severe OSA.

  5. Positive pressure ventilation in the management of acute and chronic cardiac failure: a systematic review and meta-analysis.

    Science.gov (United States)

    Nadar, Sunil; Prasad, Neeraj; Taylor, Rod S; Lip, Gregory Y H

    2005-03-18

    Chronic heart failure (CHF) is a common condition and is associated with excess morbidity and mortality, in spite of the many advances in its treatment. Chronic stable heart failure is also associated with an increased incidence of sleep-related breathing disorders, such as central sleep apnoea (CSA) and Cheyne Stokes respiration (CSR). Continuous positive airways pressure (CPAP) has been shown to alleviate the symptoms of CHF, improve left ventricular function and oxygenation. To a certain extent, CPAP also abolishes sleep-related breathing disorders in patients with chronic heart failure. In patients with acute pulmonary oedema, the use of positive pressure ventilation improves cardiac haemodynamic indices, as well as symptoms and oxygenation, and is associated with a lower need for intubation. However, some studies have cast doubts about its safety and suggest a higher rate of myocardial infarction associated with its use. In our opinion, non-invasive positive pressure ventilation and CPAP offers an adjunctive mode of therapy in patients with acute pulmonary oedema and chronic heart failure, who may not be suitable for intubation and in those not responsive to conventional therapies. Non-invasive ventilation also helps to improve oxygenation in those patients with exhaustion and respiratory acidosis. Many trials are still ongoing and the results of these studies would throw more light on the present role of non-invasive ventilation in the management of CHF.

  6. Positive expiratory pressure therapy versus other airway clearance techniques for bronchiectasis.

    Science.gov (United States)

    Lee, Annemarie L; Burge, Angela T; Holland, Anne E

    2017-09-27

    People with bronchiectasis experience chronic cough and sputum production and require the prescription of airway clearance techniques (ACTs). A common type of ACT prescribed is positive expiratory pressure (PEP) therapy. A previous review has suggested that ACTs including PEP therapy are beneficial compared to no treatment in people with bronchiectasis. However, the efficacy of PEP therapy in a stable clinical state or during an acute exacerbation compared to other ACTs in bronchiectasis is unknown. The primary aim of this review was to determine the effects of PEP therapy compared with other ACTs on health-related quality of life (HRQOL), rate of acute exacerbations, and incidence of hospitalisation in individuals with stable or an acute exacerbation of bronchiectasis.Secondary aims included determining the effects of PEP therapy upon physiological outcomes and clinical signs and symptoms compared with other ACTs in individuals with stable or an acute exacerbation of bronchiectasis. We searched the Cochrane Airways Group Specialised Register of Trials, PEDro and clinical trials registries from inception to February 2017 and we handsearched relevant journals. Randomised controlled parallel and cross-over trials that compared PEP therapy versus other ACTs in participants with bronchiectasis. We used standard methodological procedures as outlined by Cochrane. Nine studies involving 213 participants met the inclusion criteria, of which seven were cross-over in design. All studies included adults with bronchiectasis, with eight including participants in a stable clinical state and one including participants experiencing an acute exacerbation. Eight studies used oscillatory PEP therapy, using either a Flutter or Acapella device and one study used Minimal PEP therapy. The comparison intervention differed between studies. The methodological quality of studies was poor, with cross-over studies including suboptimal or no washout period, and a lack of blinding of

  7. Acute Effects of Positive Airway Pressure on Functional Mitral Regurgitation in Patients with Systolic Heart Failure

    Directory of Open Access Journals (Sweden)

    Takao Kato

    2017-11-01

    Full Text Available Background: Acute effects of positive airway pressure (PAP [including continuous PAP (CPAP and adaptive servo-ventilation, an advanced form of bi-level PAP] on functional mitral regurgitation (fMR in patients with heart failure (HF with left ventricular (LV systolic dysfunction remain unclear. Thus, whether PAP therapy reduces fMR in such patients with HF was investigated.Methods and Results: Twenty patients with HF and LV systolic dysfunction defined as LV ejection fraction (LVEF <50% (14 men; mean LVEF, 35.0 ± 11.5% with fMR underwent echocardiography during 10-min CPAP (4 and 8 cm H2O and adaptive servo-ventilation. For fMR assessment, MR jet area fraction, defined as the ratio of MR jet on color Doppler to the left atrial area, was measured. The forward stroke volume (SV index (fSVI was calculated from the time-velocity integral, cross-sectional area of the aortic annulus, and body surface area. fMR significantly reduced on CPAP at 8 cm H2O (0.30 ± 0.12 and adaptive servo-ventilation (0.29 ± 0.12, compared with the baseline phase (0.37 ± 0.12 and CPAP at 4 cm H2O (0.34 ± 0.12 (P < 0.001. The fSVI did not change in any of the PAP sessions (P = 0.888. However, significant differences in fSVI responses to PAP were found between sexes (P for interaction, 0.006, with a significant reduction in fSVI in women (P = 0.041 and between patients with baseline fSVI ≥ and < the median value (27.8 ml/m2, P for interaction, 0.018, with a significant fSVI reduction in patients with high baseline fSVI (P = 0.028. In addition, significant differences were found in fSVI responses to PAP between patients with LV end-systolic volume (LVESV index ≥ and < the median value (62.0 ml/m2, P for interaction, 0.034, with a significant fSVI increase in patients with a high LVESV index (P = 0.023.Conclusion: In patients with HF, LV systolic dysfunction, and fMR, PAP can alleviate fMR without any overall changes in forward SV. However, MR alleviation due to PAP

  8. Hemodynamic differences between continual positive and two types of negative pressure ventilation.

    Science.gov (United States)

    Lockhat, D; Langleben, D; Zidulka, A

    1992-09-01

    In seven anesthetized dogs, ventilated with matching lung volumes, tidal volumes, and respiratory rates, we compared the effects on cardiac output (CO), arterial venous oxygen saturation difference (SaO2 - SVO2), and femoral and inferior vena cava pressure (1) intermittent positive pressure ventilation with positive end-expiratory pressure (CPPV); (2) iron-lung ventilation with negative end-expiratory pressure (ILV-NEEP); (3) grid and wrap ventilation with NEEP applied to the thorax and upper abdomen (G&W-NEEP). The values of CO and SaO2 - SVO2 with ILV-NEEP were similar to those with CPPV. However, with G&W-NEEP as compared with ILV-NEEP, mean CO was greater (2.9 versus 2.6 L/min, p = 0.02) and mean (SaO2 - SVO2) was lower (26.6% versus 28.3%, p = NS). Mean PFEM-IVC was higher with G&W-NEEP than with the other types of ventilation. We conclude that (1) ILV-NEEP is hemodynamically equivalent to CPPV and (2) G&W-NEEP has less adverse hemodynamic consequences. has less adverse hemodynamic consequences.

  9. Work of breathing using different interfaces in spontaneous positive pressure ventilation: helmet, face-mask, and endotracheal tube.

    Science.gov (United States)

    Oda, Shinya; Otaki, Kei; Yashima, Nozomi; Kurota, Misato; Matsushita, Sachiko; Kumasaka, Airi; Kurihara, Hutaba; Kawamae, Kaneyuki

    2016-08-01

    Noninvasive positive pressure ventilation (NPPV) using a helmet is expected to cause inspiratory trigger delay due to the large collapsible and compliant chamber. We compared the work of breathing (WOB) of NPPV using a helmet or a full face-mask with that of invasive ventilation by tracheal intubation. We used a lung model capable of simulating spontaneous breathing (LUNGOO; Air Water Inc., Japan). LUNGOO was set at compliance (C) = 50 mL/cmH2O and resistance (R) = 5 cmH2O/L/s for normal lung simulation, C = 20 mL/cmH2O and R = 5 cmH2O/L/s for restrictive lung, and C = 50 mL/cmH2O and R = 20 cmH2O/L/s for obstructive lung. Muscle pressure was fixed at 25 cmH2O and respiratory rate at 20 bpm. Pressure support ventilation and continuous positive airway pressure were performed with each interface placed on a dummy head made of reinforced plastic that was connected to LUNGOO. We tested the inspiratory WOB difference between the interfaces with various combinations of ventilator settings (positive end-expiratory pressure 5 cmH2O; pressure support 0, 5, and 10 cmH2O). In the normal lung and restrictive lung models, WOB decreased more with the face-mask than the helmet, especially when accompanied by the level of pressure support. In the obstructive lung model, WOB with the helmet decreased compared with the other two interfaces. In the mixed lung model, there were no significant differences in WOB between the three interfaces. NPPV using a helmet is more effective than the other interfaces for WOB in obstructive lung disease.

  10. [Successful airway management using i-gel in 7 patients undergoing awake craniotomy].

    Science.gov (United States)

    Matsunami, Katsuaki; Sanuki, Michiyoshi; Yasuuji, Masakazu; Nakanuno, Ryuichi; Kato, Takahiro; Kawamoto, Masashi

    2014-07-01

    In order to secure airway during awake craniotomy, we used i-gel to perform positive-pressure ventilation in 7 patients for their anesthetic management. During removal of a tumor around the motor speech center, anesthetic management including asleep-awake-asleep technique was applied for speech testing. The technique, insertion and re-insertion of i-gel, was needed and it was easy in all the patients. During positive-pressure ventilation, peak pressure, tidal volume both for inspiration and expiration, and endtidal-CO2 were not markedly altered. Leakage around i-gel, and its differences between inspiration and expiration were negligible, while the tidal volume was adequate. We conclude that i-gel is useful for anesthetic management for awake craniotomy procedure for both securing airway and ventilation.

  11. Respiratory Strategies and Airway Management in Patients with Pulmonary Alveolar Proteinosis: A Review

    Directory of Open Access Journals (Sweden)

    Tomas Vymazal

    2015-01-01

    Full Text Available Background. Pulmonary alveolar proteinosis is a rare disorder characterized by a large accumulation of lipoproteinaceous material within the alveoli. This causes respiratory failure due to a restriction of gas exchange and changes in the ventilation/perfusion ratio. Treatment methods include noninvasive pharmacological approaches and invasive procedures, such as whole-lung lavage under general anesthesia. Methods. Based on the literature search using free-term key words, we have analyzed published articles concerning the perioperative management of adult and pediatric patients with pulmonary alveolar proteinosis. Results and Discussion. In total, 184 publications were analyzed. Only a few manuscripts were related to anesthetic, respiratory, and airway management in patients suffering from pulmonary alveolar proteinosis. Airway should be strictly separated using a double-lumen tube. Respiratory strategies involve the use of manual clapping, continuous positive airway pressure, high-frequency jet ventilation of the affected lung, and employment of venovenous extracorporeal membrane oxygenation in the most serious of cases. Conclusion. The goal of this review is to summarize the current published information about an anesthetic management strategy with a focus on airway management, ventilation, and oxygenation techniques in PAP patients.

  12. A randomized non-crossover study comparing the ProSeal and Classic laryngeal mask airway in anaesthetized children.

    Science.gov (United States)

    Lopez-Gil, M; Brimacombe, J; Garcia, G

    2005-12-01

    We tested the hypothesis that ease of insertion, oropharyngeal leak pressure, fibreoptic position, gastric insufflation, and the frequency of mucosal trauma differ between the ProSeal laryngeal mask airway (PLMA) and the classic laryngeal mask airway (cLMA) in anaesthetized children. For the PLMA, we also assessed the ease of gastric tube placement via the PLMA drain tube and measure residual gastric volume. 240 consecutive ASA I-III children aged 1-16 yr were randomized for airway management with the ProSeal or cLMA. The time taken to provide an effective airway, the number of insertion attempts, fibreoptic position of the airway tube and frequency of mucosal trauma were similar, but oropharyngeal leak pressure was higher (33 vs 26 cm H(2)O, Ptube insertion was successful at the first attempt in 106 of 120, and at the second attempt in 14 of 120. The mean (sd; range) value for residual gastric volume was 2.2 (5.9; 0-30) ml. There were no differences in performance among sizes for the PLMA and the cLMA. We conclude that ease of insertion, fibreoptic position, and frequency of mucosal trauma are similar for the PLMA and cLMA in children, but oropharyngeal leak pressure is higher and gastric insufflation less common for the PLMA. Gastric tube insertion has a high success rate, provided the PLMA is correctly positioned.

  13. Negative-Pressure Pulmonary Edema.

    Science.gov (United States)

    Bhattacharya, Mallar; Kallet, Richard H; Ware, Lorraine B; Matthay, Michael A

    2016-10-01

    Negative-pressure pulmonary edema (NPPE) or postobstructive pulmonary edema is a well-described cause of acute respiratory failure that occurs after intense inspiratory effort against an obstructed airway, usually from upper airway infection, tumor, or laryngospasm. Patients with NPPE generate very negative airway pressures, which augment transvascular fluid filtration and precipitate interstitial and alveolar edema. Pulmonary edema fluid collected from most patients with NPPE has a low protein concentration, suggesting hydrostatic forces as the primary mechanism for the pathogenesis of NPPE. Supportive care should be directed at relieving the upper airway obstruction by endotracheal intubation or cricothyroidotomy, institution of lung-protective positive-pressure ventilation, and diuresis unless the patient is in shock. Resolution of the pulmonary edema is usually rapid, in part because alveolar fluid clearance mechanisms are intact. In this review, we discuss the clinical presentation, pathophysiology, and management of negative-pressure or postobstructive pulmonary edema. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  14. Effects of Inhaled Fenoterol and Positive End-Expiratory Pressure on the Respiratory Mechanics of Patients with Chronic Obstructive Pulmonary Disease

    Directory of Open Access Journals (Sweden)

    Claude Guerin

    2005-01-01

    Full Text Available BACKGROUND: During acute ventilatory failure in patients with chronic obstructive pulmonary disease (COPD, applying external positive end-expiratory pressure (PEEPe will reopen small airways and, thus, may enhance peripheral deposition as well as the physiological effects of inhaled beta-2 agonists.

  15. Value and limitations of transpulmonary pressure calculations during intra-abdominal hypertension.

    Science.gov (United States)

    Cortes-Puentes, Gustavo A; Gard, Kenneth E; Adams, Alexander B; Faltesek, Katherine A; Anderson, Christopher P; Dries, David J; Marini, John J

    2013-08-01

    To clarify the effect of progressively increasing intra-abdominal pressure on esophageal pressure, transpulmonary pressure, and functional residual capacity. Controlled application of increased intra-abdominal pressure at two positive end-expiratory pressure levels (1 and 10 cm H2O) in an anesthetized porcine model of controlled ventilation. Large animal laboratory of a university-affiliated hospital. Eleven deeply anesthetized swine (weight 46.2 ± 6.2 kg). Air-regulated intra-abdominal hypertension (0-25 mm Hg). Esophageal pressure, tidal compliance, bladder pressure, and end-expiratory lung aeration by gas dilution. Functional residual capacity was significantly reduced by increasing intra-abdominal pressure at both positive end-expiratory pressure levels (p ≤ 0.0001) without corresponding changes of end-expiratory esophageal pressure. Above intra-abdominal pressure 5 mm Hg, plateau airway pressure increased linearly by ~ 50% of the applied intra-abdominal pressure value, associated with commensurate changes of esophageal pressure. With tidal volume held constant, negligible changes occurred in transpulmonary pressure due to intra-abdominal pressure. Driving pressures calculated from airway pressures alone (plateau airway pressure--positive end-expiratory pressure) did not equate to those computed from transpulmonary pressure (tidal changes in transpulmonary pressure). Increasing positive end-expiratory pressure shifted the predominantly negative end-expiratory transpulmonary pressure at positive end-expiratory pressure 1 cm H2O (mean -3.5 ± 0.4 cm H2O) into the positive range at positive end-expiratory pressure 10 cm H2O (mean 0.58 ± 1.2 cm H2O). Despite its insensitivity to changes in functional residual capacity, measuring transpulmonary pressure may be helpful in explaining how different levels of positive end-expiratory pressure influence recruitment and collapse during tidal ventilation in the presence of increased intra-abdominal pressure and in

  16. Upper airway finding on CT scan with and without nasal CPAP in obstructive sleep apnea patients

    Energy Technology Data Exchange (ETDEWEB)

    Akashiba, Tsuneto; Sasaki, Iwao; Kurashina, Keiji; Yoshizawa, Takayuki; Otsuka, Kenzo; Horie, Takashi (Nihon Univ., Tokyo (Japan). School of Medicine)

    1991-04-01

    The area of upper airway (from the nasopharynx to the hypopharynx) was measured by means of computed tomography (CT) scan in 15 confirmed cases of obstructive sleep apnea (OSA) and in 4 normal controls while they were awake. The minimum cross-sectional area (MA) of the upper airway was 14.7+-20.0 mm{sup 2} in OSA patients and 80.0+-33.1 mm{sup 2} in normal controls and the difference was statistically significant (p<0.01). In OSA patients, MA did not correlate with age, body weight, apnea index, desaturation index, mean nadir-SO{sub 2} and lowest SO{sub 2}. MA was also measured with OSA patients while nasal continuous positive airway pressure (NCPAP) of 10 cmH{sub 2}O was applied and it was found that MA was significantly widened when NCPAP therapy was performed. We conclude that upper airway narrowing is consistent finding in OSA patients but the degree of narrowing does not correlate with parameters of apnea and gas exchange during sleep, and NCPAP is effective to widen the area of upper airway in OSA patients. (author).

  17. Lung sound analysis helps localize airway inflammation in patients with bronchial asthma

    Directory of Open Access Journals (Sweden)

    Shimoda T

    2017-03-01

    Full Text Available Terufumi Shimoda,1 Yasushi Obase,2 Yukio Nagasaka,3 Hiroshi Nakano,1 Akiko Ishimatsu,1 Reiko Kishikawa,1 Tomoaki Iwanaga1 1Clinical Research Center, Fukuoka National Hospital, Fukuoka, 2Second Department of Internal Medicine, School of Medicine, Nagasaki University, Nagasaki, 3Kyoto Respiratory Center, Otowa Hospital, Kyoto, Japan Purpose: Airway inflammation can be detected by lung sound analysis (LSA at a single point in the posterior lower lung field. We performed LSA at 7 points to examine whether the technique could identify the location of airway inflammation in patients with asthma. Patients and methods: Breath sounds were recorded at 7 points on the body surface of 22 asthmatic subjects. Inspiration sound pressure level (ISPL, expiration sound pressure level (ESPL, and the expiration-to-inspiration sound pressure ratio (E/I were calculated in 6 frequency bands. The data were analyzed for potential correlation with spirometry, airway hyperresponsiveness (PC20, and fractional exhaled nitric oxide (FeNO. Results: The E/I data in the frequency range of 100–400 Hz (E/I low frequency [LF], E/I mid frequency [MF] were better correlated with the spirometry, PC20, and FeNO values than were the ISPL or ESPL data. The left anterior chest and left posterior lower recording positions were associated with the best correlations (forced expiratory volume in 1 second/forced vital capacity: r=–0.55 and r=–0.58; logPC20: r=–0.46 and r=–0.45; and FeNO: r=0.42 and r=0.46, respectively. The majority of asthmatic subjects with FeNO ≥70 ppb exhibited high E/I MF levels in all lung fields (excluding the trachea and V50%pred <80%, suggesting inflammation throughout the airway. Asthmatic subjects with FeNO <70 ppb showed high or low E/I MF levels depending on the recording position, indicating uneven airway inflammation. Conclusion: E/I LF and E/I MF are more useful LSA parameters for evaluating airway inflammation in bronchial asthma; 7-point lung

  18. X-cephalometric study of different parts of the upper airway space and changes in hyoid position following mandibular fractures.

    Science.gov (United States)

    Chen, L-J; Zhao, M-C; Pan, X-F; Wei, Y-Q; Wang, D-Y

    2013-09-01

    This study analyses the different parts of the upper airway space and the changes in hyoid position. The results provide a clinical reference for developing timely and effective treatment programmes for patients with mandibular fractures caused by maxillofacial trauma. Standard X-cephalometric measurements of the lateral skull of 210 subjects were taken. The subjects were divided into four fracture groups: condylar, mandibular angle, mandibular body, and parasymphyseal. The radiographs of the mandibular fracture groups were compared with the normal occlusion group to analyse the upper airway space and the changes in hyoid position. Different types of fractures have different effects on the upper airway space. Bilateral mandibular body fracture and the parasymphyseal fracture have a significant influence on the lower oropharyngeal and laryngopharyngeal airway spaces, with serious obstructions severely restricting the ventilatory function of patients. Fractures at different parts of the mandibular structure are closely related to the upper airway and hyoid position.

  19. Adolescents with obstructive sleep apnea adhere poorly to positive airway pressure (PAP, but PAP users show improved attention and school performance.

    Directory of Open Access Journals (Sweden)

    Dean W Beebe

    2011-03-01

    Full Text Available Obstructive Sleep Apnea (OSA is associated with medical and neurobehavioral morbidity across the lifespan. Positive airway pressure (PAP treatment has demonstrated efficacy in treating OSA and has been shown to improve daytime functioning in adults, but treatment adherence can be problematic. There are nearly no published studies examining functional outcomes such as academic functioning in adolescents treated with PAP. This study was conducted as an initial step towards determining whether PAP treatment improves daytime functioning among adolescents with OSA.Self-reported academic grades, self- and parent-reported academic quality of life, and objectively-measured attention were assessed before and after PAP was clinically initiated in a sample of 13 obese adolescents with OSA, as well as 15 untreated obese Controls without OSA. Based on adherence data, the treated group was divided into PAP Users (n = 6 and Non-Adherent participants (n = 7.Though demographically similar, the three groups significantly differed in how their academic performance and attention scores changed from baseline to follow-up. Non-Adherent participants showed worsening functioning over time, while PAP Users showed stable or improved functioning, similar to controls.Although many adolescents prescribed PAP for OSA are non-adherent to the treatment, those who adhere to treatment can display improved attention and academic functioning.

  20. Effects of recruitment maneuver and positive end-expiratory pressure on respiratory mechanics and transpulmonary pressure during laparoscopic surgery.

    Science.gov (United States)

    Cinnella, Gilda; Grasso, Salvatore; Spadaro, Savino; Rauseo, Michela; Mirabella, Lucia; Salatto, Potito; De Capraris, Antonella; Nappi, Luigi; Greco, Pantaleo; Dambrosio, Michele

    2013-01-01

    The authors tested the hypothesis that during laparoscopic surgery, Trendelenburg position and pneumoperitoneum may worsen chest wall elastance, concomitantly decreasing transpulmonary pressure, and that a protective ventilator strategy applied after pneumoperitoneum induction, by increasing transpulmonary pressure, would result in alveolar recruitment and improvement in respiratory mechanics and gas exchange. In 29 consecutive patients, a recruiting maneuver followed by positive end-expiratory pressure 5 cm H(2)O maintained until the end of surgery was applied after pneumoperitoneum induction. Respiratory mechanics, gas exchange, blood pressure, and cardiac index were measured before (T(BSL)) and after pneumoperitoneum with zero positive end-expiratory pressure (T(preOLS)), after recruitment with positive end-expiratory pressure (T(postOLS)), and after peritoneum desufflation with positive end-expiratory pressure (T(end)). Esophageal pressure was used for partitioning respiratory mechanics between lung and chest wall (data are mean ± SD): on T(preOLS), chest wall elastance (E(cw)) and elastance of the lung (E(L)) increased (8.2 ± 0.9 vs. 6.2 ± 1.2 cm H(2)O/L, respectively, on T(BSL); P = 0.00016; and 11.69 ± 1.68 vs. 9.61 ± 1.52 cm H(2)O/L on T(BSL); P = 0.0007). On T(postOLS), both chest wall elastance and E(L) decreased (5.2 ± 1.2 and 8.62 ± 1.03 cm H(2)O/L, respectively; P = 0.00015 vs. T(preOLS)), and Pao(2)/inspiratory oxygen fraction improved (491 ± 107 vs. 425 ± 97 on T(preOLS); P = 0.008) remaining stable thereafter. Recruited volume (the difference in lung volume for the same static airway pressure) was 194 ± 80 ml. Pplat(RS) remained stable while inspiratory transpulmonary pressure increased (11.65 + 1.37 cm H(2)O vs. 9.21 + 2.03 on T(preOLS); P = 0.007). All respiratory mechanics parameters remained stable after abdominal desufflation. Hemodynamic parameters remained stable throughout the study. In patients submitted to laparoscopic surgery in

  1. [Compliance with continuous positive airway pressure therapy in patients with sleep apnea/hypopnea syndrome].

    Science.gov (United States)

    Gallego, Claudio W; Dibur, Eduardo; Salomone, César; Di Bartolo, Carlos G

    2004-01-01

    Predictive factors and compliance level were evaluated in a group of patients with sleep apnea syndrome under CPAP treatment, assessing side effects and equipment condition: silicone interface (SI), mask-conectors (M-C), air tube (AT) and head strap (HS). Patients with >3mo treatment were included, clock counter reading was registered at the beginning, 2 and 4 mo. Patients were considered compliant (C+) when usage was >4h/day and >5day/week. Of 46 patients (male 34; age 62 +/- 9years; BMI 33 +/- 7kg/m2; AHI 38 +/- 18/h; time of therapy 2.1 +/- 1.7years; CPAP 9 +/- 1.4 cmH2O), 34 had a clock counter and 24 (71%) were C+. Initial symptoms included: somnolence (65%), snoring (39%), bed-partner witnessed apneas (28%). Comparing C+ and C- we didn't find significant difference in age, BMI, CPAP pressure, length of therapy, AHI and pre-treatment Epworth classification. Referred vs. measured time of use in C+ and C- were 6.6 +/- 1 vs. 6.1 +/- 1 h/d (p=0.02) and 5.6 +/- 1 vs. 2.4 +/- 1 h/d (pcongestion 27%, sleep disruption 11%, CPAP noisy 9%, dry nose, rhinorrhea and skin irritation 7%. Twenty seven percent of patients reduced the CPAP use because of the SE. Correction strategies included: humidifier, nasal steroid, surgery or infiltration of turbinates. Comparing the condition of SI, M-C, AT and HS between 1year of use, we observed a lower percentage of fine elements (87 to 44%, 74 to 44%, 83 to 44%, 91 to 78%, respectively). Most common defects included stiffness of SI, cracks in SI, M-C and AT, loose conexions. The study confirms the importance of objective monitoring in patients with CPAP. Side effects and equipment condition require special attention because this could affect an effective treatment.

  2. Therapeutic CPAP Level Predicts Upper Airway Collapsibility in Patients With Obstructive Sleep Apnea.

    Science.gov (United States)

    Landry, Shane A; Joosten, Simon A; Eckert, Danny J; Jordan, Amy S; Sands, Scott A; White, David P; Malhotra, Atul; Wellman, Andrew; Hamilton, Garun S; Edwards, Bradley A

    2017-06-01

    Upper airway collapsibility is a key determinant of obstructive sleep apnea (OSA) which can influence the efficacy of certain non-continuous positive airway pressure (CPAP) treatments for OSA. However, there is no simple way to measure this variable clinically. The present study aimed to develop a clinically implementable tool to evaluate the collapsibility of a patient's upper airway. Collapsibility, as characterized by the passive pharyngeal critical closing pressure (Pcrit), was measured in 46 patients with OSA. Associations were investigated between Pcrit and data extracted from patient history and routine polysomnography, including CPAP titration. Therapeutic CPAP level, demonstrated the strongest relationship to Pcrit (r2=0.51, p CPAP level (6.2 ± 0.6 vs. 10.3 ± 0.4 cmH2O, p -2 cmH2O). A therapeutic CPAP level ≤8.0 cmH2O was sensitive (89%) and specific (84%) for detecting a mildly collapsible upper airway. When applied to the independent validation data set (n = 74), this threshold maintained high specificity (91%) but reduced sensitivity (75%). Our data demonstrate that a patient's therapeutic CPAP requirement shares a strong predictive relationship with their Pcrit and may be used to accurately differentiate OSA patients with mild airway collapsibility from those with moderate-to-severe collapsibility. Although this relationship needs to be confirmed prospectively, our findings may provide clinicians with better understanding of an individual patient's OSA phenotype, which ultimately could assist in determining which patients are most likely to respond to non-CPAP therapies. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  3. Transnasal Humidified Rapid-Insufflation Ventilatory Exchange (THRIVE): a physiological method of increasing apnoea time in patients with difficult airways.

    Science.gov (United States)

    Patel, A; Nouraei, S A R

    2015-03-01

    Emergency and difficult tracheal intubations are hazardous undertakings where successive laryngoscopy-hypoxaemia-re-oxygenation cycles can escalate to airway loss and the 'can't intubate, can't ventilate' scenario. Between 2013 and 2014, we extended the apnoea times of 25 patients with difficult airways who were undergoing general anaesthesia for hypopharyngeal or laryngotracheal surgery. This was achieved through continuous delivery of transnasal high-flow humidified oxygen, initially to provide pre-oxygenation, and continuing as post-oxygenation during intravenous induction of anaesthesia and neuromuscular blockade until a definitive airway was secured. Apnoea time commenced at administration of neuromuscular blockade and ended with commencement of jet ventilation, positive-pressure ventilation or recommencement of spontaneous ventilation. During this time, upper airway patency was maintained with jaw-thrust. Transnasal Humidified Rapid-Insufflation Ventilatory Exchange (THRIVE) was used in 15 males and 10 females. Mean (SD [range]) age at treatment was 49 (15 [25-81]) years. The median (IQR [range]) Mallampati grade was 3 (2-3 [2-4]) and direct laryngoscopy grade was 3 (3-3 [2-4]). There were 12 obese patients and nine patients were stridulous. The median (IQR [range]) apnoea time was 14 (9-19 [5-65]) min. No patient experienced arterial desaturation gaseous exchange through flow-dependent deadspace flushing. It has the potential to transform the practice of anaesthesia by changing the nature of securing a definitive airway in emergency and difficult intubations from a pressured stop-start process to a smooth and unhurried undertaking. © 2014 The Authors Anaesthesia published by John Wiley & Sons Ltd on behalf of Association of Anaesthetists of Great Britain and Ireland.

  4. A multicentre randomised controlled trial and economic evaluation of continuous positive airway pressure for the treatment of obstructive sleep apnoea syndrome in older people: PREDICT.

    Science.gov (United States)

    McMillan, Alison; Bratton, Daniel J; Faria, Rita; Laskawiec-Szkonter, Magda; Griffin, Susan; Davies, Robert J; Nunn, Andrew J; Stradling, John R; Riha, Renata L; Morrell, Mary J

    2015-06-01

    The therapeutic and economic benefits of continuous positive airway pressure (CPAP) for the treatment of obstructive sleep apnoea syndrome (OSAS) have been established in middle-aged people. In older people there is a lack of evidence. To determine the clinical efficacy of CPAP in older people with OSAS and to establish its cost-effectiveness. A randomised, parallel, investigator-blinded multicentre trial with within-trial and model-based cost-effectiveness analysis. Two hundred and seventy-eight patients, aged ≥ 65 years with newly diagnosed OSAS [defined as oxygen desaturation index at ≥ 4% desaturation threshold level for > 7.5 events/hour and Epworth Sleepiness Scale (ESS) score of ≥ 9] recruited from 14 hospital-based sleep services across the UK. CPAP with best supportive care (BSC) or BSC alone. Autotitrating CPAP was initiated using standard clinical practice. BSC was structured advice on minimising sleepiness. Subjective sleepiness at 3 months, as measured by the ESS (ESS mean score: months 3 and 4) and cost-effectiveness over 12 months, as measured in quality-adjusted life-years (QALYs) calculated using the European Quality of Life-5 Dimensions (EQ-5D) and health-care resource use, information on which was collected monthly from patient diaries. Subjective sleepiness at 12 months (ESS mean score: months 10, 11 and 12) and objective sleepiness, disease-specific and generic quality of life, mood, functionality, nocturia, mobility, accidents, cognitive function, cardiovascular risk factors and events at 3 and 12 months. Two hundred and seventy-eight patients were randomised to CPAP (n = 140) or BSC (n = 138) over 27 months and 231 (83%) patients completed the trial. Baseline ESS score was similar in both groups [mean (standard deviation; SD) CPAP 11.5 (3.3), BSC 11.4 (4.2)]; groups were well balanced for other characteristics. The mean (SD) in ESS score at 3 months was -3.8 (0.4) in the CPAP group and -1.6 (0.3) in the BSC group. The

  5. Pediatric supraglottic airway devices in clinical practice: A prospective observational study.

    Science.gov (United States)

    Kleine-Brueggeney, Maren; Gottfried, Anne; Nabecker, Sabine; Greif, Robert; Book, Malte; Theiler, Lorenz

    2017-09-02

    Supraglottic airway devices (SGA) are commonly used in pediatric anesthesia and serve as primary or back-up devices for difficult airway management. Most SGA are marketed without proper clinical evaluation. The purpose of this study was to evaluate the performance of the pediatric LMA Supreme™, Air-Q® and Ambu® Aura-i™. This prospective observational study was performed at Bern University Hospital, Switzerland. With ethics committee approval and a waiver for written informed consent 240 children undergoing elective surgery with an ASA class I-III and a weight of 5-30 kg were included. Three different pediatric supraglottic airway devices were assessed: The LMA Supreme™, Air-Q® and Ambu® Aura-i™. Primary outcome parameter was airway leak pressure. Secondary outcome parameters included first attempt and overall success rate, insertion time, fiberoptic view through the SGA, and adverse events. The primary hypothesis was that the mean airway leak pressure of each tested SGA was 20 cmH 2 O ± 10%. None of the SGA showed a mean airway leak pressure of 20 cmH 2 O ± 10%, but mean airway leak pressures differed significantly between devices [LMA Supreme™ 18.0 (3.4) cmH 2 O, Air-Q® 15.9 (3.2) cmH 2 O, Ambu® Aura-i™ 17.3 (3.7) cmH 2 O, p < 0.001]. First attempt success rates (LMA Supreme™ 100%, Air-Q® 90%, Ambu® Aura-i™ 91%, p = 0.02) and overall success rates (LMA Supreme™ 100%, Air-Q® 91%, Ambu® Aura-i™ 95%, p = 0.02) also differed significantly. Insertion times ranged from 20 (7) seconds (Air-Q®) to 24 (6) seconds (LMA Supreme™, Airway leak pressures ranged from 16 to 18 cmH 2 O, enabling positive pressure ventilation with all successful SGA. The highest success rates were achieved by the LMA Supreme™, which was also

  6. Effect of a patient engagement tool on positive airway pressure adherence: analysis of a German healthcare provider database.

    Science.gov (United States)

    Woehrle, Holger; Arzt, Michael; Graml, Andrea; Fietze, Ingo; Young, Peter; Teschler, Helmut; Ficker, Joachim H

    2018-01-01

    This study investigated the addition of a real-time feedback patient engagement tool on positive airway pressure (PAP) adherence when added to a proactive telemedicine strategy. Data from a German healthcare provider (ResMed Healthcare Germany) were retrospectively analyzed. Patients who first started PAP therapy between 1 September 2009 and 30 April 2014, and were managed using telemedicine (AirView™; proactive care) or telemedicine + patient engagement tool (AirView™ + myAir™; patient engagement) were eligible. Patient demographics, therapy start date, sleep-disordered breathing indices, device usage hours, and therapy termination rate were obtained and compared between the two groups. The first 500 patients managed by telemedicine-guided care and a patient engagement tool were matched with 500 patients managed by telemedicine-guided care only. The proportion of nights with device usage ≥4 h was 77 ± 25% in the patient engagement group versus 63 ± 32% in the proactive care group (p < 0.001). Therapy termination occurred less often in the patient engagement group (p < 0.001). The apnea-hypopnea index was similar in the two groups, but leak was significantly lower in the patient engagement versus proactive care group (2.7 ± 4.0 vs 4.1 ± 5.3 L/min; p < 0.001). Addition of a patient engagement tool to telemonitoring-guided proactive care was associated with higher device usage and lower leak. This suggests that addition of an engagement tool may help improve PAP therapy adherence and reduce mask leak. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Continuous positive airway pressure breathing increases the spread of sensory blockade after low-thoracic epidural injection of lidocaine.

    NARCIS (Netherlands)

    Visser, W.A.; Gielen, M.J.M.; Giele, J.L.P.

    2006-01-01

    Factors affecting the distribution of sensory blockade after epidural injection of local anesthetics remain incompletely clarified. To evaluate if increasing intrathoracic pressure affects the spread of thoracic epidural anesthesia, we randomized 20 patients who received an epidural catheter at the

  8. Positive signature-tagged mutagenesis in Pseudomonas aeruginosa: tracking patho-adaptive mutations promoting airways chronic infection.

    Directory of Open Access Journals (Sweden)

    Irene Bianconi

    2011-02-01

    Full Text Available The opportunistic pathogen Pseudomonas aeruginosa can establish life-long chronic infections in the airways of cystic fibrosis (CF patients. Persistent lifestyle is established with P. aeruginosa patho-adaptive variants, which are clonal with the initially-acquired strains. Several reports indicated that P. aeruginosa adapts by loss-of-function mutations which enhance fitness in CF airways and sustain its clonal expansion during chronic infection. To validate this model of P. aeruginosa adaptation to CF airways and to identify novel genes involved in this microevolution, we designed a novel approach of positive-selection screening by PCR-based signature-tagged mutagenesis (Pos-STM in a murine model of chronic airways infection. A systematic positive-selection scheme using sequential rounds of in vivo screenings for bacterial maintenance, as opposed to elimination, generated a list of genes whose inactivation increased the colonization and persistence in chronic airways infection. The phenotypes associated to these Pos-STM mutations reflect alterations in diverse aspects of P. aeruginosa biology which include lack of swimming and twitching motility, lack of production of the virulence factors such as pyocyanin, biofilm formation, and metabolic functions. In addition, Pos-STM mutants showed altered invasion and stimulation of immune response when tested in human respiratory epithelial cells, indicating that P. aeruginosa is prone to revise the interaction with its host during persistent lifestyle. Finally, sequence analysis of Pos-STM genes in longitudinally P. aeruginosa isolates from CF patients identified signs of patho-adaptive mutations within the genome. This novel Pos-STM approach identified bacterial functions that can have important clinical implications for the persistent lifestyle and disease progression of the airway chronic infection.

  9. All India Difficult Airway Association 2016 guidelines for the management of unanticipated difficult tracheal intubation in obstetrics

    Directory of Open Access Journals (Sweden)

    Venkateswaran Ramkumar

    2016-01-01

    Full Text Available The various physiological changes in pregnancy make the parturient vulnerable for early and rapid desaturation. Severe hypoxaemia during intubation can potentially compromise two lives (mother and foetus. Thus tracheal intubation in the pregnant patient poses unique challenges, and necessitates meticulous planning, ready availability of equipment and expertise to ensure maternal and foetal safety. The All India Difficult Airway Association (AIDAA proposes a stepwise plan for the safe management of the airway in obstetric patients. These guidelines have been developed based on available evidence; wherever robust evidence was lacking, recommendations were arrived at by consensus opinion of airway experts, incorporating the responses to a questionnaire sent to members of the AIDAA and the Indian Society of Anaesthesiologists (ISA. Modified rapid sequence induction using gentle intermittent positive pressure ventilation with pressure limited to ≤20 cm H 2 O is acceptable. Partial or complete release of cricoid pressure is recommended when face mask ventilation, placement of supraglottic airway device (SAD or tracheal intubation prove difficult. One should call for early expert assistance. Maternal SpO 2 should be maintained ≥95%. Apnoeic oxygenation with nasal insufflation of 15 L/min oxygen during apnoea should be performed in all patients. If tracheal intubation fails, a second- generation SAD should be inserted. The decision to continue anaesthesia and surgery via the SAD, or perform fibreoptic-guided intubation via the SAD or wake up the patient depends on the urgency of surgery, foeto-maternal status and availability of resources and expertise. Emergency cricothyroidotomy must be performed if complete ventilation failure occurs.

  10. A Novel Therapy for Chronic Sleep-Onset Insomnia: A Retrospective, Nonrandomized Controlled Study of Auto-Adjusting, Dual-Level, Positive Airway Pressure Technology.

    Science.gov (United States)

    Krakow, Barry; Ulibarri, Victor A; McIver, Natalia D; Nadorff, Michael R

    2016-09-29

    Evidence indicates that behavioral or drug therapy may not target underlying pathophysiologic mechanisms for chronic insomnia, possibly due to previously unrecognized high rates (30%-90%) of sleep apnea in chronic insomnia patients. Although treatment studies with positive airway pressure (PAP) demonstrate decreased severity of chronic sleep maintenance insomnia in patients with co-occurring sleep apnea, sleep-onset insomnia has not shown similar results. We hypothesized advanced PAP technology would be associated with decreased sleep-onset insomnia severity in a sample of predominantly psychiatric patients with comorbid sleep apnea. We reviewed charts of 74 severe sleep-onset insomnia patients seen from March 2011 to August 2015, all meeting American Academy of Sleep Medicine Work Group criteria for a chronic insomnia disorder and all affirming behavioral and psychological origins for insomnia (averaging 10 of 18 indicators/patient), as well as averaging 2 or more psychiatric symptoms or conditions: depression (65.2%), anxiety (41.9%), traumatic exposure (35.1%), claustrophobia (29.7%), panic attacks (28.4%), and posttraumatic stress disorder (20.3%). All patients failed continuous or bilevel PAP and were manually titrated with auto-adjusting PAP modes (auto-bilevel and adaptive-servo ventilation). At 1-year follow-up, patients were compared through nonrandom assignment on the basis of a PAP compliance metric of > 20 h/wk (56 PAP users) versus insomnia severity (Hedges' g = 1.72) and sleep-onset insomnia (g = 2.07) compared to partial users (g = 1.04 and 0.91, respectively). Both global and sleep-onset insomnia severity decreased below moderate levels in PAP users compared to partial users whose outcomes persisted at moderately severe levels. In a nonrandomized controlled retrospective study, advanced PAP technology (both auto-bilevel and adaptive servo-ventilation) were associated with large decreases in insomnia severity for sleep-onset insomnia patients who

  11. Comparison of streamlined liner of the pharynx airway (SLIPA TM with the laryngeal mask airway Proseal TM for lower abdominal laparoscopic surgeries in paralyzed, anesthetized patients

    Directory of Open Access Journals (Sweden)

    Ashraf Abualhassan Abdellatif

    2011-01-01

    Full Text Available Context: Supraglottic airway devices have been used as an alternative to tracheal intubation during laparoscopic surgery. Aims: The study was designed to compare the efficacy of Streamlined Liner of the Pharynx Airway (SLIPA for positive pressure ventilation and postoperative complications with the Laryngeal Mask Airway ProSeal (PLMA for patients undergoing lower abdominal laparoscopies under general anesthesia with controlled ventilation. Settings and Design: Prospective, crossover randomized controlled trial performed on patients undergoing lower abdominal laparoscopic surgeries. Methods: A total of 120 patients undergoing lower abdominal laparoscopic surgeries were randomly allocated into two equal groups; PLMA and SLIPA groups. Number of intubation attempts, insertion time, ease of insertion, and fiberoptic bronchoscopic view were recorded. Lung mechanics data were collected 5 minutes after securing the airway, then after abdominal insufflation. Blood traces and regurgitation were checked for; postoperative sore throat and other complications were recorded. Statistical Analysis: Arithmetic mean and standard deviation values were calculated and statistical analyses were performed for each group. Independent sample t-test was used to compare continuous variables exhibiting normal distribution, and Chi-squared test for noncontinuous variables. P value <0.05 was considered significant. Results: Insertion time, first insertion success rate, and ease of insertion were comparable in both groups. Fiberoptic bronchoscopic view was significantly better and epiglottic downfolding was significantly lower in SLIPA group. Sealing pressure and lung mechanics were similar. Gastric distension was not observed in both groups. Postoperative sore throat was significantly higher in PACU in PLMA group. Blood traces on the device were significantly more in SLIPA group. Conclusions: SLIPA can be used as a useful alternative to PLMA in patients undergoing lower

  12. Evaluation of Pressure Generated by Resistors From Different Positive Expiratory Pressure Devices.

    Science.gov (United States)

    Fagevik Olsén, Monika; Carlsson, Maria; Olsén, Erik; Westerdahl, Elisabeth

    2015-10-01

    Breathing exercises with positive expiratory pressure (PEP) are used to improve pulmonary function and airway clearance. Different PEP devices are available, but there have been no studies that describe the pressure generated by different resistors. The purpose of this study was to compare pressures generated from the proprietary resistor components of 4 commercial flow-dependent PEP valves with all other parameters kept constant. Resistors from 4 flow-regulated PEP devices (Pep/Rmt system, Wellspect HealthCare; Pipe P breathing exerciser, Koo Medical Equipment; Mini-PEP, Philips Respironics [including resistors by Rüsch]; and 15-mm endo-adapter, VBM Medizintechnik) were tested randomly by a blinded tester at constant flows of 10 and 18 L/min from an external gas system. All resistors were tested 3 times. Resistors with a similar diameter produced statistically significant different pressures at the same flow. The differences were smaller when the flow was 10 L/min compared with 18 L/min. The differences were also smaller when the diameter of the resistor was increased. The pressures produced by the 4 resistors of the same size were all significantly different when measuring 1.5- and 2.0-mm resistors at a flow of 10 L/min and 2.0-mm resistors at a flow of 18 L/min (P < .001). There were no significant differences between any of the resistors when testing sizes of 4.5 and 5.0 mm at either flow. The Mini-PEP and adapter resistors gave the highest pressures. Pressures generated by the different proprietary resistor components of 4 commercial PEP devices were not comparable, even though the diameter of the resistors is reported to be the same. The pressures generated were significantly different, particularly when using small-diameter resistors at a high flow. Therefore, the resistors may not be interchangeable. This is important information for clinicians, particularly when considering PEP for patients who do not tolerate higher pressures. Copyright © 2015 by

  13. Prevention of respiratory complications of the surgical patient: actionable plan for continued process improvement.

    Science.gov (United States)

    Ruscic, Katarina J; Grabitz, Stephanie D; Rudolph, Maíra I; Eikermann, Matthias

    2017-06-01

    Postoperative respiratory complications (PRCs) increase hospitalization time, 30-day mortality and costs by up to $35 000. These outcomes measures have gained prominence as bundled payments have become more common. Results of recent quantitative effectiveness studies and clinical trials provide a framework that helps develop center-specific treatment guidelines, tailored to minimize the risk of PRCs. The implementation of those protocols should be guided by a local, respected, and visible facilitator who leads proper implementation while inviting center-specific input from surgeons, anesthesiologists, and other perioperative stakeholders. Preoperatively, patients should be risk-stratified for PRCs to individualize intraoperative choices and postoperative pathways. Laparoscopic compared with open surgery improves respiratory outcomes. High-risk patients should be treated by experienced providers based on locally developed bundle-interventions to optimize intraoperative treatment and ICU bed utilization. Intraoperatively, lung-protective ventilation (procedure-specific positive end-expiratory pressure utilization, and low driving pressure) and moderately restrictive fluid therapy should be used. To achieve surgical relaxation, high-dose neuromuscular blocking agents (and reversal agents) as well as high-dose opioids should be avoided; inhaled anesthetics improve surgical conditions while protecting the lungs. Patients should be extubated in reverse Trendelenburg position. Postoperatively, continuous positive airway pressure helps prevent airway collapse and protocolized, early mobilization improves cognitive and respiratory function.

  14. Airway responsiveness to mannitol in asthma is associated with chymase-positive mast cells and eosinophilic airway inflammation

    DEFF Research Database (Denmark)

    Sverrild, Asger; Bergqvist, Anders; Baines, Katherine J

    2016-01-01

    BACKGROUND: Airway hyperresponsiveness (AHR) to inhaled mannitol is associated with indirect markers of mast cell activation and eosinophilic airway inflammation. It is unknown how AHR to mannitol relates to mast cell phenotype, mast cell function and measures of eosinophilic inflammation in airway...... tissue. We compared the number and phenotype of mast cells, mRNA expression of mast cell-associated genes and number of eosinophils in airway tissue of subjects with asthma and healthy controls in relation to AHR to mannitol. METHODS: Airway hyperresponsiveness to inhaled mannitol was measured in 23 non......-smoking, corticosteroid-free asthmatic individuals and 10 healthy controls. Mast cells and eosinophils were identified in mucosal biopsies from all participants. Mast cells were divided into phenotypes based on the presence of chymase. mRNA expression of mast cell-associated genes was measured by real-time PCR. RESULTS...

  15. Effects of fixed functional therapy on tongue and hyoid positions and posterior airway.

    Science.gov (United States)

    Ozdemir, Fulya; Ulkur, Feyza; Nalbantgil, Didem

    2014-03-01

    To evaluate how therapy with a fixed functional appliance affects airway dimensions, dentoalveolar changes, and tongue and hyoid positions. A retrospective study was carried out on 46 pre- and posttreatment lateral cephalometric radiographs of 23 post-peak Class II patients (12 girls, 11 boys) treated with a Forsus Fatigue Resistant Device (FRD) appliance. The radiographies were taken at the start and at the end of Forsus FRD appliance therapy when a Class I or overcorrected Class I canine and molar relationship was achieved. The process took an average of 5 months 13 days ± 1 month 4 days. Skeletal and dental parameters were measured using Dolphin software, and the sagittal airway area was measured by AutoCAD software. Analyses of the pre- and posttreatment means revealed that there was no statistically significant skeletal correction of the sagittal malocclusion; increase of lower incisor inclination, decrease of upper incisor inclination, decrease of interincisal angle, and rotation of occlusal plane all contributed to the reduction of overjet. The tongue area and intermaxillary space area increased in response to these dentoalveolar changes; however, there was no statistically significant change in the hyoid position or the oropharyngeal area between the two time points. The dentoalveolar changes produced by Forsus FRD appliance did not cause any significant posterior airway changes in young adult patients.

  16. A multicentre, randomised controlled, non-inferiority trial, comparing nasal high flow with nasal continuous positive airway pressure as primary support for newborn infants with early respiratory distress born in Australian non-tertiary special care nurseries (the HUNTER trial): study protocol.

    Science.gov (United States)

    Manley, Brett J; Roberts, Calum T; Arnolda, Gaston R B; Wright, Ian M R; Owen, Louise S; Dalziel, Kim M; Foster, Jann P; Davis, Peter G; Buckmaster, Adam G

    2017-06-23

    Nasal high-flow (nHF) therapy is a popular mode of respiratory support for newborn infants. Evidence for nHF use is predominantly from neonatal intensive care units (NICUs). There are no randomised trials of nHF use in non-tertiary special care nurseries (SCNs). We hypothesise that nHF is non-inferior to nasal continuous positive airway pressure (CPAP) as primary support for newborn infants with respiratory distress, in the population cared for in non-tertiary SCNs. The HUNTER trial is an unblinded Australian multicentre, randomised, non-inferiority trial. Infants are eligible if born at a gestational age ≥31 weeks with birth weight ≥1200 g and admitted to a participating non-tertiary SCN, are 1 hour. Infants are randomised to treatment with either nHF or CPAP. The primary outcome is treatment failure within 72 hours of randomisation, as determined by objective oxygenation, apnoea or blood gas criteria or by a clinical decision that urgent intubation and mechanical ventilation, or transfer to a tertiary NICU, is required. Secondary outcomes include incidence of pneumothorax requiring drainage, duration of respiratory support, supplemental oxygen and hospitalisation, costs associated with hospital care, cost-effectiveness, parental stress and satisfaction and nursing workload. Multisite ethical approval for the study has been granted by The Royal Children's Hospital, Melbourne, Australia (Trial Reference No. 34222), and by each participating site. The trial is currently recruiting in eight centres in Victoria and New South Wales, Australia, with one previous site no longer recruiting. The trial results will be published in a peer-reviewed journal and will be presented at national and international conferences. Australian and New Zealand Clinical Trials Registry (ANZCTR): ACTRN12614001203640; pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted

  17. Reproducibility of airway luminal size in asthma measured by HRCT.

    Science.gov (United States)

    Brown, Robert H; Henderson, Robert J; Sugar, Elizabeth A; Holbrook, Janet T; Wise, Robert A

    2017-10-01

    Brown RH, Henderson RJ, Sugar EA, Holbrook JT, Wise RA, on behalf of the American Lung Association Airways Clinical Research Centers. Reproducibility of airway luminal size in asthma measured by HRCT. J Appl Physiol 123: 876-883, 2017. First published July 13, 2017; doi:10.1152/japplphysiol.00307.2017.-High-resolution CT (HRCT) is a well-established imaging technology used to measure lung and airway morphology in vivo. However, there is a surprising lack of studies examining HRCT reproducibility. The CPAP Trial was a multicenter, randomized, three-parallel-arm, sham-controlled 12-wk clinical trial to assess the use of a nocturnal continuous positive airway pressure (CPAP) device on airway reactivity to methacholine. The lack of a treatment effect of CPAP on clinical or HRCT measures provided an opportunity for the current analysis. We assessed the reproducibility of HRCT imaging over 12 wk. Intraclass correlation coefficients (ICCs) were calculated for individual airway segments, individual lung lobes, both lungs, and air trapping. The ICC [95% confidence interval (CI)] for airway luminal size at total lung capacity ranged from 0.95 (0.91, 0.97) to 0.47 (0.27, 0.69). The ICC (95% CI) for airway luminal size at functional residual capacity ranged from 0.91 (0.85, 0.95) to 0.32 (0.11, 0.65). The ICC measurements for airway distensibility index and wall thickness were lower, ranging from poor (0.08) to moderate (0.63) agreement. The ICC for air trapping at functional residual capacity was 0.89 (0.81, 0.94) and varied only modestly by lobe from 0.76 (0.61, 0.87) to 0.95 (0.92, 0.97). In stable well-controlled asthmatic subjects, it is possible to reproducibly image unstimulated airway luminal areas over time, by region, and by size at total lung capacity throughout the lungs. Therefore, any changes in luminal size on repeat CT imaging are more likely due to changes in disease state and less likely due to normal variability. NEW & NOTEWORTHY There is a surprising lack

  18. Control of OSA during automatic positive airway pressure titration in a clinical case series: predictors and accuracy of device download data.

    Science.gov (United States)

    Huang, Hsin-Chia Carol; Hillman, David R; McArdle, Nigel

    2012-09-01

    To investigate the factors associated with physiologic control of obstructive sleep apnea (OSA) during automatic positive airway pressure (APAP) titration in a clinical series. To also assess the usefulness of apnea-hypopnea index (AHI) data downloaded from the APAP device (Dev AHI). Retrospective review of a consecutive series of patients with OSA who underwent APAP titration (Autoset Spirit, ResMed, Bella Vista, New South Wales, Australia ) with simultaneous polysomnographic (PSG) monitoring in the sleep laboratory. Tertiary sleep clinic. There were 190 consecutive patients with OSA referred for APAP titration. There were 58% of patients who achieved optimal or good control of OSA (titration PSG AHI titration. The independent predictors of titration PSG AHI were a history of cardiac disease and elevated central apnea and arousal indices during the diagnostic study. Although the median and interquartile range (IQR) AHI from the device (7.0, 3.9-11.6 events/hr) was only slightly less than the PSG AHI (7.8, 3.9-14.4 events/hr, P = 0.04) during titration, case-by-case agreement between the two measures was poor (chi-square titration is often poor, and close clinical follow-up is particularly needed in patients with a history of cardiac disease or with high arousal or central apnea indices on the diagnostic study. Device AHI does not reliably assess control during APAP titration, and PSG assessment may be required if clinical response to treatment is poor. The findings relate to the ResMed AutoSet device and may not apply to other devices.

  19. Tracheomalacia treatment using a large-diameter, custom-made airway stent in a case with mounier-kuhn syndrome.

    Science.gov (United States)

    Ozdemir, Cengiz; Sökücü, Sinem Nedime; Karasulu, Levent; Altın, Sedat; Dalar, Levent

    2014-01-01

    Mounier-Kuhn Syndrome (MKS) is a rare congenital disease that presents with abnormal enlargement in the central airways. In MKS, tracheomegaly is accompanied by difficulty in expelling recurrent lung infections and bronchiectasia. We presented a patient with MKS where commercially made stents were inadequate for stabilization and a custom-made, self-expandable metallic stent with a diameter of 28 mm and length of 100 mm was used. Chest pain that was thought to develop due to the stent and that disappeared after stent removal may be considered the main complication leading to stent removal. Continuous positive airway pressure therapy (CPAP) therapy was planned for the control of symptoms, which re-emerged after stent removal. This case is presented as an example that complications developing due to the stent as well as patient noncompliance may lead to stent removal, even when useful results are obtained from treatment of MKS.

  20. Regional anesthesia in difficult airway: The quest for a solution continues.

    Science.gov (United States)

    Khetarpal, Ranjana; Chatrath, Veena; Dhawan, Akshay; Attri, Joginder Pal

    2016-01-01

    Difficult airway, a scenario with potentially life threatening outcome, is routinely encountered by an anesthesiologist leaving him with the dilemma of whether to use regional anesthesia (RA) or general anesthesia. Our study aims to look into this problem. The literature search was performed in the Google, PubMed, and Medscape using key words "regional anesthesia, difficult airway, pregnancy, ventilation, intubation, epidural anesthesia, nerve blocks." More than 38 free full articles and books published from the year 1987 to 2014 were retrieved and studied. At first sight, RA may appear to offer an ideal solution as it helps to avoid the problem of difficult airway. However, the possibility of a total spinal block, failed or incomplete RA, local anesthetic toxicity or unforeseen surgical complication may make it imperative that the airway is secured. The correct decision can only be made by the anesthetist when all the relevant clinical information is taken into account. It is also important to ensure that before considering RA in a patient of difficult airway, an anesthesiologist must have a preformulated strategy for intubation.

  1. Effects of positive airway pressure therapy on cardiovascular and metabolic markers in males with obstructive sleep apnea

    Directory of Open Access Journals (Sweden)

    A. Feliciano

    2017-07-01

    Full Text Available Introduction: Obstructive sleep apnea syndrome (OSAS is associated with cardiovascular/metabolic complications. Some analytical parameters (homocysteine, glycemic and lipidic profiles are recognized markers of these consequences. Limited data is available on the association of these markers and OSAS's severity/response to positive airway pressure therapy (PAP. Material and methods: In this prospective study we analyzed polysomnographic and analytical data of male patients admitted to sleep laboratory. The aim was to evaluate metabolic/cardiovascular markers in snorers and OSAS patients, to relate with sleep parameters and PAP response. One-hundred and three patients were included, and 73 (71% were OSAS patients. OSAS patients were similar to snorers except for higher body mass index (BMI and dyslipidemia. Severe OSAS patients showed higher glycemia, HbA1c, insulin, and insulin resistance, and lower HDL cholesterol in comparison to mild–moderate (p < 0.05, p < 0.05, p < 0.001, p < 0.001, p < 0.05, respectively. Glycemic profile and triglycerides were slightly correlated with OSAS severity. 46 OSAS patients were submitted to 6 months of PAP, with a statistical decrease in mean values of homocysteine, glycemia, total and LDL cholesterol (p < 0.05, p < 0.05, p < 0.05, respectively, and in glycemia and LDL cholesterol in severe group only (p < 0.05, p < 0.05, respectively. Results: This study demonstrated an association between glucose metabolism parameters and triglycerides with OSAS severity underlying the complexity of the process leading to cardiovascular/metabolic complications in this disorder. Moreover, homocysteine, glycemic and lipidic profiles changed significantly after 6 months of PAP therapy in OSAS, supporting its cardiovascular and metabolic protective effect. Conclusion: Our study has reinforced the importance of analytical cardiovascular/metabolic evaluation as

  2. Randomized crossover comparison of the laryngeal mask airway classic with i-gel laryngeal mask airway in the management of difficult airway in post burn neck contracture patients

    Directory of Open Access Journals (Sweden)

    Jeevan Singh

    2012-01-01

    Full Text Available Purpose: The objective of the study was to compare the performance of i-gel supraglottic airway with cLMA in difficult airway management in post burn neck contracture patients and assess the feasibility of i-gel use for emergency airway management in difficult airway situation with reduced neck movement and limited mouth opening. Methods: Prospective, crossover, randomized controlled trial was performed amongst forty eight post burn neck contracture patients with limited mouth opening and neck movement. i-gel and cLMA were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, visualization of square wave pattern. Results: Success rate for the i-gel was 91.7% versus 79.2% for the cLMA. i-gel required shorter insertion time (19.3 seconds vs. 23.5 seconds, P=0.000. Airway leak pressure difference was statistically significant (i-gel 21.2 cm H20; cLMA 16.9 cm H 2 0; P=0.00. Fiberoptic view through the i-gel showed there were less epiglottic downfolding and better fiberoptic view of the glottis than cLMA. Overall agreement in insertion outcome for i-gel was 22/24 (91.7% successes and 2/24(8.3% failure and for cLMA, 19/24 (79.16% successes and 5/24 (16.7% failure in the first attempt. Conclusion: The i-gel is cheap, effective airway device which is easier to insert and has better clinical performance in the difficult airway management of the airway in the post burn contracture of the neck. Our study shows that i-gel is feasible for emergency airway management in difficult airway situation with reduced neck movement and limited mouth opening in post burn neck.

  3. ProSeal laryngeal mask airway improves oxygenation when used as a conduit prior to laryngoscope guided intubation in bariatric patients

    Directory of Open Access Journals (Sweden)

    Aparna Sinha

    2013-01-01

    Full Text Available Background: The primary objective of this study was to compare the effect of ventilation using the ProSeal TM laryngeal mask airway (PLMA with facemask and oropharyngeal airway (FM, prior to laryngoscopy, on arterial oxygenation in morbidly obese patients undergoing bariatric surgery. Methods: Forty morbidly obese patients were randomly recruited to either PLMA or FM. After pre-oxygenation (FiO 2 1.0 in the ramp position with continuous positive airway pressure of 10 cm H 2 O for 5 min, anaesthesia was induced. Following loss of jaw thrust oropharyngeal airway, the FM and PLMA were inserted. On achieving paralysis, volume control ventilation with PEEP (5 cm H 2 O was initiated. The difficulty in mask ventilation (DMV in FM, number of attempts at PLMA and laryngoscopy were graded (Cormack and Lehane in all patients. Time from onset of laryngoscopy to endotracheal tube confirmation was recorded. Hypoxia was defined as mild (SpO 2 ≤95%, moderate (SpO 2 ≤90% and severe (SpO 2 ≤85%. Results: Significant rise in pO 2 was observed within both groups ( P=0.001, and this was significantly higher in the PLMA ( P=0.0001 when compared between the groups. SpO 2 ≥ 90% ( P=0.018 was seen in 19/20 (95% patients in PLMA and 13/20 (65% in FM at confirmation of tracheal tube. A strong association was found between DMV and Cormack Lehane in the FM group and with number of attempts in the PLMA group. No adverse events were observed. Conclusion: ProSeal TM laryngeal mask airway as conduit prior to laryngoscopy in morbidly obese patients seems effective in increasing oxygen reserves, and can be suggested as a routine airway management technique when managing the airway in the morbidly obese.

  4. A clinical comparison of disposable airway devices | Strydom ...

    African Journals Online (AJOL)

    Cuff pressures were significantly higher in the Ambu™ and LMA Unique™ (p = 0.001). Maximum airway pressure attainable after 5 minutes was significantly higher in the Ambu™ (p = 0.036). Airway trauma as graded by visible blood on the device was low, and similar between groups (p = 0.237). Secretions were negligible ...

  5. Flow-synchronized nasal intermittent positive pressure ventilation in the preterm infant: development of a project

    Directory of Open Access Journals (Sweden)

    Corrado Moretti

    2013-06-01

    Full Text Available This manuscript describes the experience of our team in developing a flow-triggered nasal respiratory support for the neonate and its related clinical applications. Although mechanical ventilation (MV via an endotracheal tube has undoubtedly led to improvement in neonatal survival in the last 40 years, the prolonged use of this technique may predispose the infant to the development of many possible complications, first of all, bronchopulmonary dysplasia (BPD. Avoiding mechanical ventilation is thought to be a critical goal, and different modes of non invasive respiratory support may reduce the intubation rate: nasal continuous positive airway pressure (NCPAP, nasal intermittent positive pressure ventilation (NIPPV and its more advantageous form, synchronized nasal intermittent positive pressure ventilation (SNIPPV. SNIPPV was initially performed by a capsule placed on the baby’s abdomen. To overcome the disadvantages of the abdominal capsule, our team decided to create a flow-sensor that could be interposed between the nasal prongs and the Y piece. Firstly we developed a hot-wire flow-sensor to trigger the ventilator and we showed that flow-SNIPPV can support the inspiratory effort in the post-extubation period more effectively than NCPAP. But, although accurate, the proper functioning of the hot-wire flow-sensor was easily compromised by secretions or moisture, and therefore we started to use as flow-sensor a simpler differential pressure transducer. In a following trial using the new device, we were able to demonstrate that flow-SNIPPV was more effective than conventional NCPAP in decreasing extubation failure in preterm infants who had been ventilated for respiratory distress syndrome (RDS. More recently we used flow-SNIPPV as the primary mode of ventilation, after surfactant replacement, reducing MV need and favorably affecting short-term morbidities of treated premature infants. We also successfully applied SNIPPV to treat apnea of

  6. Supplemental Carbon Dioxide Stabilizes the Upper Airway in Volunteers Anesthetized with Propofol.

    Science.gov (United States)

    Ruscic, Katarina Jennifer; Bøgh Stokholm, Janne; Patlak, Johann; Deng, Hao; Simons, Jeroen Cedric Peter; Houle, Timothy; Peters, Jürgen; Eikermann, Matthias

    2018-05-10

    Propofol impairs upper airway dilator muscle tone and increases upper airway collapsibility. Preclinical studies show that carbon dioxide decreases propofol-mediated respiratory depression. We studied whether elevation of end-tidal carbon dioxide (PETCO2) via carbon dioxide insufflation reverses the airway collapsibility (primary hypothesis) and impaired genioglossus muscle electromyogram that accompany propofol anesthesia. We present a prespecified, secondary analysis of previously published experiments in 12 volunteers breathing via a high-flow respiratory circuit used to control upper airway pressure under propofol anesthesia at two levels, with the deep level titrated to suppression of motor response. Ventilation, mask pressure, negative pharyngeal pressure, upper airway closing pressure, genioglossus electromyogram, bispectral index, and change in end-expiratory lung volume were measured as a function of elevation of PETCO2 above baseline and depth of propofol anesthesia. PETCO2 augmentation dose-dependently lowered upper airway closing pressure with a decrease of 3.1 cm H2O (95% CI, 2.2 to 3.9; P < 0.001) under deep anesthesia, indicating improved upper airway stability. In parallel, the phasic genioglossus electromyogram increased by 28% (23 to 34; P < 0.001). We found that genioglossus electromyogram activity was a significant modifier of the effect of PETCO2 elevation on closing pressure (P = 0.005 for interaction term). Upper airway collapsibility induced by propofol anesthesia can be reversed in a dose-dependent manner by insufflation of supplemental carbon dioxide. This effect is at least partly mediated by increased genioglossus muscle activity.

  7. High frequency jet ventilation and intermittent positive pressure ventilation. Effect of cerebral blood flow in patients after open heart surgery

    International Nuclear Information System (INIS)

    Pittet, J.F.; Forster, A.; Suter, P.M.

    1990-01-01

    Attenuation of ventilator-synchronous pressure fluctuations of intracranial pressure has been demonstrated during high frequency ventilation in animal and human studies, but the consequences of this effect on cerebral blood flow have not been investigated in man. We compared the effects of high frequency jet ventilation and intermittent positive pressure ventilation on CBF in 24 patients investigated three hours after completion of open-heart surgery. The patients were investigated during three consecutive periods with standard sedation (morphine, pancuronium): a. IPPV; b. HFJV; c. IPPV. Partial pressure of arterial CO 2 (PaCO 2 : 4.5-5.5 kPa) and rectal temperature (35.5 to 37.5 degree C) were maintained constant during the study. The CBF was measured by intravenous 133 Xe washout technique. The following variables were derived from the cerebral clearance of 133 Xe: the rapid compartment flow, the initial slope index, ie, a combination of the rapid and the slow compartment flows, and the ratio of fast compartment flow over total CBF (FF). Compared to IPPV, HFJV applied to result in the same mean airway pressure did not produce any change in pulmonary gas exchange, mean systemic arterial pressure, and cardiac index. Similarly, CBF was not significantly altered by HFJV. However, important variations of CBF values were observed in three patients, although the classic main determinants of CBF (PaCO 2 , cerebral perfusion pressure, Paw, temperature) remained unchanged. Our results suggest that in patients with normal systemic hemodynamics, the effects of HFJV and IPPV on CBF are comparable at identical levels of mean airway pressure

  8. Airway obstruction and gas leak during mask ventilation of preterm infants in the delivery room.

    LENUS (Irish Health Repository)

    2011-07-01

    Preterm infants with inadequate breathing receive positive pressure ventilation (PPV) by mask with variable success. The authors examined recordings of PPV given to preterm infants in the delivery room for prevalence of mask leak and airway obstruction.

  9. Comparison of Laryngeal Mask Airway Supreme and Laryngeal Mask Airway Proseal with respect to oropharyngeal leak pressure during laparoscopic cholecystectomy: a randomised controlled trial.

    Science.gov (United States)

    Beleña, José M; Núñez, Mónica; Anta, Diego; Carnero, Maria; Gracia, José L; Ayala, José L; Alvarez, Raquel; Yuste, Javier

    2013-03-01

    A comparison of the efficacy and safety of the Laryngeal Mask Airway (LMA) Supreme (LMAS) versus the LMA Proseal (LMAP) in elective laparoscopic cholecystectomy. To compare the LMAS with LMAP in terms of ventilatory efficacy, airway leak pressure (airway protection), ease-of-use and complications. Prospective, single-blind, randomised, controlled study. The Hospital del Sureste and Hospital Ramon y Cajal, Madrid, between May 2009 and March 2011. The Hospital del Sureste is a secondary hospital and Hospital Ramon y Cajal is a tertiary hospital. Patients undergoing elective laparoscopic cholecystectomy were studied following informed consent. Inclusion criteria were American Society of Anesthesiologists physical status I to III and age 18 or more. Exclusion criteria were BMI more than 40 kg m, symptomatic hiatus hernia or severe gastro-oesophageal reflux. Anaesthesiologists experienced in the use of LMAP and LMAS participated in the trial. One hundred twenty-two patients were randomly allocated to LMAS or LMAP. Our primary outcome measure was the oropharyngeal leak pressure (OLP). Secondary outcomes were the time and number of attempts for insertion, ease of insertion of the drain tube, adequacy of ventilation and the incidence of complication. Patients were interviewed postoperatively to evaluate the presence of sore throat, dysphagia or dysphonia. Two patients were excluded when surgery changed from laparoscopic to open. A total of 120 patients were finally included in the analysis. The mean OLP in the LMAP group was significantly higher than that in the LMAS group (30.7 ± 6.2 versus 26.8 ± 4.1 cmH2O;P drain tube, complications and postoperative pharyngolaryngeal adverse events were similar in both groups. The LMAP has a higher OLP and achieves a higher maximum tidal volume compared to the LMAS, in patients undergoing elective laparoscopic cholecystectomy. The success of the first attempt insertion was higher for the LMAS.

  10. Difficult Airway Response Team: A Novel Quality Improvement Program for Managing Hospital-Wide Airway Emergencies

    Science.gov (United States)

    Mark, Lynette J.; Herzer, Kurt R.; Cover, Renee; Pandian, Vinciya; Bhatti, Nasir I.; Berkow, Lauren C.; Haut, Elliott R.; Hillel, Alexander T.; Miller, Christina R.; Feller-Kopman, David J.; Schiavi, Adam J.; Xie, Yanjun J.; Lim, Christine; Holzmueller, Christine; Ahmad, Mueen; Thomas, Pradeep; Flint, Paul W.; Mirski, Marek A.

    2015-01-01

    Background Difficult airway cases can quickly become emergencies, increasing the risk of life-threatening complications or death. Emergency airway management outside the operating room is particularly challenging. Methods We developed a quality improvement program—the Difficult Airway Response Team (DART)—to improve emergency airway management outside the operating room. DART was implemented by a team of anesthesiologists, otolaryngologists, trauma surgeons, emergency medicine physicians, and risk managers in 2005 at The Johns Hopkins Hospital in Baltimore, Maryland. The DART program had three core components: operations, safety, and education. The operations component focused on developing a multidisciplinary difficult airway response team, standardizing the emergency response process, and deploying difficult airway equipment carts throughout the hospital. The safety component focused on real-time monitoring of DART activations and learning from past DART events to continuously improve system-level performance. This objective entailed monitoring the paging system, reporting difficult airway events and DART activations to a web-based registry, and using in situ simulations to identify and mitigate defects in the emergency airway management process. The educational component included development of a multispecialty difficult airway curriculum encompassing case-based lectures, simulation, and team building/communication to ensure consistency of care. Educational materials were also developed for non-DART staff and patients to inform them about the needs of patients with difficult airways and ensure continuity of care with other providers after discharge. Results Between July 2008 and June 2013, DART managed 360 adult difficult airway events comprising 8% of all code activations. Predisposing patient factors included body mass index > 40, history of head and neck tumor, prior difficult intubation, cervical spine injury, airway edema, airway bleeding, and previous

  11. Difficult airway response team: a novel quality improvement program for managing hospital-wide airway emergencies.

    Science.gov (United States)

    Mark, Lynette J; Herzer, Kurt R; Cover, Renee; Pandian, Vinciya; Bhatti, Nasir I; Berkow, Lauren C; Haut, Elliott R; Hillel, Alexander T; Miller, Christina R; Feller-Kopman, David J; Schiavi, Adam J; Xie, Yanjun J; Lim, Christine; Holzmueller, Christine; Ahmad, Mueen; Thomas, Pradeep; Flint, Paul W; Mirski, Marek A

    2015-07-01

    Difficult airway cases can quickly become emergencies, increasing the risk of life-threatening complications or death. Emergency airway management outside the operating room is particularly challenging. We developed a quality improvement program-the Difficult Airway Response Team (DART)-to improve emergency airway management outside the operating room. DART was implemented by a team of anesthesiologists, otolaryngologists, trauma surgeons, emergency medicine physicians, and risk managers in 2005 at The Johns Hopkins Hospital in Baltimore, Maryland. The DART program had 3 core components: operations, safety, and education. The operations component focused on developing a multidisciplinary difficult airway response team, standardizing the emergency response process, and deploying difficult airway equipment carts throughout the hospital. The safety component focused on real-time monitoring of DART activations and learning from past DART events to continuously improve system-level performance. This objective entailed monitoring the paging system, reporting difficult airway events and DART activations to a Web-based registry, and using in situ simulations to identify and mitigate defects in the emergency airway management process. The educational component included development of a multispecialty difficult airway curriculum encompassing case-based lectures, simulation, and team building/communication to ensure consistency of care. Educational materials were also developed for non-DART staff and patients to inform them about the needs of patients with difficult airways and ensure continuity of care with other providers after discharge. Between July 2008 and June 2013, DART managed 360 adult difficult airway events comprising 8% of all code activations. Predisposing patient factors included body mass index >40, history of head and neck tumor, prior difficult intubation, cervical spine injury, airway edema, airway bleeding, and previous or current tracheostomy. Twenty

  12. Tracheomalacia Treatment Using a Large-Diameter, Custom-Made Airway Stent in a Case with Mounier-Kuhn Syndrome

    Directory of Open Access Journals (Sweden)

    Cengiz Özdemir

    2014-01-01

    Full Text Available Mounier-Kuhn Syndrome (MKS is a rare congenital disease that presents with abnormal enlargement in the central airways. In MKS, tracheomegaly is accompanied by difficulty in expelling recurrent lung infections and bronchiectasia. We presented a patient with MKS where commercially made stents were inadequate for stabilization and a custom-made, self-expandable metallic stent with a diameter of 28 mm and length of 100 mm was used. Chest pain that was thought to develop due to the stent and that disappeared after stent removal may be considered the main complication leading to stent removal. Continuous positive airway pressure therapy (CPAP therapy was planned for the control of symptoms, which re-emerged after stent removal. This case is presented as an example that complications developing due to the stent as well as patient noncompliance may lead to stent removal, even when useful results are obtained from treatment of MKS.

  13. Out-of-hospital noninvasive ventilation: epidemiology, technology and equipment

    Directory of Open Access Journals (Sweden)

    John Scott Baird

    2012-04-01

    Full Text Available Noninvasive ventilation has been utilized successfully in the pre- and out-of-hospital settings for a variety of disorders, including respiratory distress syndrome in neonates, neurologic and pulmonary diseases in infants and children, and heart failure as well as chronic obstructive pulmonary disease in adults. A variety of interfaces as well as mechanical positive pressure devices have been used: simple continuous positive airway pressure devices are available which do not require sophisticated equipment, while a broad spectrum of ventilators have been used to provide bilevel positive airway pressure. Extensive training of transport teams may be important, particularly when utilizing bilevel positive airway pressure in infants and children.

  14. The effect of positive end-expiratory pressure on pulse pressure ...

    African Journals Online (AJOL)

    The effect of positive end-expiratory pressure on pulse pressure variation. FJ Smith, M Geyser, I Schreuder, PJ Becker. Abstract. Objectives: To determine the effect of different levels of positive end-expiratory pressure (PEEP) on pulse pressure variation (PPV). Design: An observational study. Setting: Operating theatres of a ...

  15. Use of continuous positive airway pressure (CPAP) in neonatal units--a survey of current preferences and practice in Germany.

    Science.gov (United States)

    Roehr, C C; Schmalisch, G; Khakban, A; Proquitté, H; Wauer, R R

    2007-04-26

    There is only limited evidence regarding the equipment or the settings (pressure and flow) at which CPAP should be applied in neonatal care. Aims of this nationwide survey of German neonatal units were to investigate (1) for which clinical indications CPAP was employed, (2) which CPAP equipment was used, (3) which CPAP settings were applied. A questionnaire on the use of CPAP was sent to all children's hospitals in Germany. Data were stratified and compared by level of medical care provided (non-academic children's hospital, academic teaching hospital and university children's hospital). 274 institutions were contacted by mailed questionnaire. The response rate was 86%, 90 non-academic children's hospitals, 119 academic teaching hospitals and 26 university children's hospitals replied. (1) There were no statistically significant difference in CPAP use between the institutions: 231 (98%) used CPAP for treating respiratory distress syndrome, 225 (96%) for treating apnoea-bradycardia-syndrome and 230 (98%) following extubation. (2) Commercial CPAP systems were employed by 71% of units, the others used a combination of different devices. Respirator generated CPAP was most commonly used. Exclusively mononasal CPAP was used by only 9%, and binasal CPAP by 55% of institutions. (3) Median CPAP was 4.5 cm H2O (range 3-7), median maximum CPAP was 7 cm H2O (range 4-10), with no statistically significant differences between the hospitals. Between units, CPAP was given via a broad range of CPAP systems and at varying pressure settings. The reported differences reflects personal experiences and preferences, rather than sound evidence from clinical trials.

  16. Prolonged lateral steep position impairs respiratory mechanics during continuous lateral rotation therapy in respiratory failure.

    Science.gov (United States)

    Schellongowski, Peter; Losert, Heidrun; Locker, Gottfried J; Laczika, Klaus; Frass, Michael; Holzinger, Ulrike; Bojic, Andja; Staudinger, Thomas

    2007-04-01

    To establish whether prolonged lateral steep position during continuous rotation therapy leads to improvement on pulmonary gas exchange, respiratory mechanics and hemodynamics. Prospective observational study. Intensive care unit of a university hospital. Twelve consecutive patients suffering from acute lung injury or adult respiratory distress syndrome undergoing continuous rotation therapy. Blood gas analysis, static lung compliance, blood pressure, cardiac index and pulmonary shunt fraction were measured in supine as well as in left and right lateral steep position at 62 degrees during continuous rotation therapy (phase I). Rotation was then stopped for 30 min with the patients in supine position, left and right lateral steep position, and the same measurements were performed every 10 min (phase II). Phase I and II revealed no significant changes in PaO(2)/FiO(2) ratio, mean arterial blood pressure, pulmonary shunt fraction, or cardiac index. Significantly lower static compliance was observed in lateral steep position than in supine position (pposition than in left and right lateral steep position (ppositioning impairs the compliance of the respiratory system. Prolonged lateral steep position does not lead to benefits with respect to oxygenation or hemodynamics. Individual response to the different positions is unpredictable. The pauses in "extreme" positions should be as short as possible.

  17. Airway basement membrane perimeter in human airways is not a constant; potential implications for airway remodeling in asthma.

    Science.gov (United States)

    McParland, Brent E; Paré, Peter D; Johnson, Peter R A; Armour, Carol L; Black, Judith L

    2004-08-01

    Many studies that demonstrate an increase in airway smooth muscle in asthmatic patients rely on the assumption that bronchial internal perimeter (P(i)) or basement membrane perimeter (P(bm)) is a constant, i.e., not affected by fixation pressure or the degree of smooth muscle shortening. Because it is the basement membrane that has been purported to be the indistensible structure, this study examines the assumption that P(bm) is not affected by fixation pressure. P(bm) was determined for the same human airway segment (n = 12) fixed at distending pressures of 0 cmH(2)O and 21 cmH(2)O in the absence of smooth muscle tone. P(bm) for the segment fixed at 0 cmH(2)O was determined morphometrically, and the P(bm) for the same segment, had the segment been fixed at 21 cmH(2)O, was predicted from knowing the luminal volume and length of the airway when distended to 21 cmH(2)O (organ bath-derived P(i)). To ensure an accurate transformation of the organ bath-derived P(i) value to a morphometry-derived P(bm) value, had the segment been fixed at 21 cmH(2)O, the relationship between organ bath-derived P(i) and morphometry-derived P(bm) was determined for five different bronchial segments distended to 21 cmH(2)O and fixed at 21 cmH(2)O (r(2) = 0.99, P < 0.0001). Mean P(bm) for bronchial segments fixed at 0 cmH(2)O was 9.4 +/- 0.4 mm, whereas mean predicted P(bm), had the segments been fixed at 21 cmH(2)O, was 14.1 +/- 0.5 mm (P < 0.0001). This indicates that P(bm) is not a constant when isolated airway segments without smooth muscle tone are fixed distended to 21 cmH(2)O. The implication of these results is that the increase in smooth muscle mass in asthma may have been overestimated in some previous studies. Therefore, further studies are required to examine the potential artifact using whole lungs with and without abolition of airway smooth muscle tone and/or inflation.

  18. Airway management by physician-staffed Helicopter Emergency Medical Services - a prospective, multicentre, observational study of 2,327 patients.

    Science.gov (United States)

    Sunde, Geir Arne; Heltne, Jon-Kenneth; Lockey, David; Burns, Brian; Sandberg, Mårten; Fredriksen, Knut; Hufthammer, Karl Ove; Soti, Akos; Lyon, Richard; Jäntti, Helena; Kämäräinen, Antti; Reid, Bjørn Ole; Silfvast, Tom; Harm, Falko; Sollid, Stephen J M

    2015-08-07

    Despite numerous studies on prehospital airway management, results are difficult to compare due to inconsistent or heterogeneous data. The objective of this study was to assess advanced airway management from international physician-staffed helicopter emergency medical services. We collected airway data from 21 helicopter emergency medical services in Australia, England, Finland, Hungary, Norway and Switzerland over a 12-month period. A uniform Utstein-style airway template was used for collecting data. The participating services attended 14,703 patients on primary missions during the study period, and 2,327 (16 %) required advanced prehospital airway interventions. Of these, tracheal intubation was attempted in 92 % of the cases. The rest were managed with supraglottic airway devices (5 %), bag-valve-mask ventilation (2 %) or continuous positive airway pressure (0.2 %). Intubation failure rates were 14.5 % (first-attempt) and 1.2 % (overall). Cardiac arrest patients showed significantly higher first-attempt intubation failure rates (odds ratio: 2.0; 95 % CI: 1.5-2.6; p < 0.001) compared to non-cardiac arrest patients. Complications were recorded in 13 %, with recognised oesophageal intubation being the most frequent (25 % of all patients with complications). For non-cardiac arrest patients, important risk predictors for first-attempt failure were patient age (a non-linear association) and administration of sedatives (reduced failure risk). The patient's sex, provider's intubation experience, trauma type (patient category), indication for airway intervention and use of neuromuscular blocking agents were not risk factors for first-attempt intubation failure. Advanced airway management in physician-staffed prehospital services was performed frequently, with high intubation success rates and low complication rates overall. However, cardiac arrest patients showed significantly higher first-attempt failure rates compared to non-cardiac arrest patients. All

  19. Effects of body position and sex group on tongue pressure generation.

    Science.gov (United States)

    Dietsch, Angela M; Cirstea, Carmen M; Auer, Ed T; Searl, Jeff P

    2013-11-01

    Fine control of orofacial musculature is necessary to precisely accelerate and decelerate the articulators across exact distances for functional speech and coordinated swallows (Amerman & Parnell, 1990; Benjamin, 1997; Kent, Duffy, Slama, Kent, & Clift, 2001). Enhanced understanding of neural control for such movements could clarify the nature of and potential remediation for some dysarthrias and other orofacial myofunctional impairments. Numerous studies have measured orolingual force and accuracy during speech and nonspeech tasks, but have focused on young adults, maximum linguapalatal pressures, and upright positioning (O'Day, Frank, Montgomery, Nichols, & McDade, 2005; Solomon & Munson, 2004; Somodi, Robin, & Luschei, 1995; Youmans, Youmans, & Stierwalt, 2009). Patients' medical conditions or testing procedures such as concurrent neuroimaging may preclude fully upright positioning during oral motor assessments in some cases. Since judgments about lingual strength and coordination can influence clinical decisions regarding the functionality of swallowing and speech, it is imperative to understand any effects of body positioning differences. In addition, sex differences in the control of such tasks are not well defined. Therefore, this study evaluated whether pressures exerted during tongue movements differ in upright vs. supine body position in healthy middle-aged men and women. Twenty healthy middle-aged adults compressed small air-filled plastic bulbs in the oral cavity at predetermined fractions of task-specific peak pressure in a randomized block design. Tasks including phoneme repetitions and nonspeech isometric contractions were executed in upright and supine positions. Participants received continuous visual feedback regarding targets and actual exerted pressures. Analyses compared average pressure values for each subject, task, position, and effort level. Speech-like and nonspeech tongue pressures did not differ significantly across body position or sex

  20. The effect of sleep onset on upper airway muscle activity in patients with sleep apnoea versus controls

    Science.gov (United States)

    Fogel, Robert B; Trinder, John; White, David P; Malhotra, Atul; Raneri, Jill; Schory, Karen; Kleverlaan, Darci; Pierce, Robert J

    2005-01-01

    Pharyngeal dilator muscles are important in the pathophysiology of obstructive sleep apnoea syndrome (OSA). We have previously shown that during wakefulness, the activity of both the genioglossus (GGEMG) and tensor palatini (TPEMG) is greater in patients with OSA compared with controls. Further, EMG activity decreases at sleep onset, and the decrement is greater in apnoea patients than in healthy controls. In addition, it is known that the prevalence of OSA is greater in middle-aged compared with younger men. Thus, we had two goals in this study. First we compared upper airway muscle activity between young and middle-aged healthy men compared with men with OSA. We also explored the mechanisms responsible for the decrement in muscle activity at sleep onset in these groups. We investigated muscle activity, ventilation , and upper airway resistance (UAR) during wakefulness and sleep onset (transition from α to θ EEG activity) in all three groups. Measurements were obtained during basal breathing (BB) and nasal continuous positive airway pressure (CPAP) was applied to reduce negative pressure-mediated muscle activation). We found that during wakefulness there was a gradation of GGEMG and UAR (younger < older < OSA) and that muscle activity was reduced by the application of nasal CPAP (to a greater degree in the OSA patients). Although CPAP eliminated differences in UAR during wakefulness and sleep, GGEMG remained greater in the OSA patients. During sleep onset, a greater initial fall in GGEMG was seen in the OSA patients followed by subsequent muscle recruitment in the third to fifth breaths following the α to θ transition. On the CPAP night, and GGEMG still fell further in the OSA patients compared with control subjects. CPAP prevented the rise in UAR at sleep onset along with the associated recruitment in GGEMG. Differences in TPEMG among the groups were not significant. These data suggest that the middle-aged men had upper airway function midway between that of

  1. Enhanced airway dilation by positive-pressure inflation of the lungs compared with active deep inspiration in patients with asthma

    NARCIS (Netherlands)

    Slats, Annelies M.; Janssen, Kirsten; de Jeu, Ronald C.; van der Plas, Dirk T.; Schot, Robert; van den Aardweg, Joost G.; Sterk, Peter J.

    2008-01-01

    Deep inspiration temporarily reduces induced airways obstruction in healthy subjects. This bronchodilatory effect of deep inspiration is impaired in asthma. Passive machine-assisted lung inflation may augment bronchodilation compared with an active deep inspiration in patients with asthma by either

  2. Estudo comparativo entre a pressão positiva intermitente (Reanimador de Müller e contínua no pós-operatório de cirurgia de revascularização do miocárdio Comparative study between intermittent (Müller Reanimator and continuous positive airway pressure in the postoperative period of coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Andréa Pires Müller

    2006-03-01

    Full Text Available OBJETIVO: Comparar o efeito da aplicação da pressão positiva intermitente e contínua em pacientes no pós-operatório de cirurgia de revascularização do miocárdio. MÉTODOS: Neste estudo foram considerados quarenta pacientes, divididos em dois grupos: um submetido a pressão positiva contínua (Grupo CPAP, e outro submetido a pressão intermitente (Grupo Reanimador de Müller. Os pacientes foram avaliados nos momentos: pré-operatório, 3ª, 24ª e 48ª horas, em relação às diversas variáveis do estudo. RESULTADOS: Os grupos de pacientes eram homogêneos em relação a diversas variáveis demográficas e clínicas. Os valores gasométricos de PO2, PCO2 e SO2 estiveram dentro dos parâmetros de normalidade e não foram encontradas diferenças significantes entre os grupos. Na ventilometria os grupos apresentaram diferenças significativas no volume corrente e freqüência respiratória no pós-operatório de 48 horas. A dispnéia e a participação da musculatura acessória, nas avaliações do pós-operatório, foram encontradas com freqüência significativamente maior nos pacientes submetidos ao CPAP. Pacientes submetidos ao Reanimador de Müller apresentaram radiografia de tórax normal com maior freqüência do que pacientes submetidos ao CPAP. CONCLUSÃO: Observou-se que ambos os recursos foram capazes de manter valores de PO2, PCO2 e SO2 dentro da normalidade. Porém, quando se busca a reexpansão pulmonar, com menor carga de trabalho imposta, o Reanimador de Müller foi mais efetivo pela forma mais rápida de ação e, conseqüentemente, apresentou menores índices de dispnéia, freqüência respiratória (FR e atividade de musculatura acessória.OBJECTIVE: To compare the effect of the use of intermittent and continuous positive airway pressure in postoperative patients undergoing coronary artery bypass grafting. METHODS: This study included forty patients divided into two groups: one undergoing continuous positive airway

  3. Continuous Blood Pressure Monitoring in Daily Life

    Science.gov (United States)

    Lopez, Guillaume; Shuzo, Masaki; Ushida, Hiroyuki; Hidaka, Keita; Yanagimoto, Shintaro; Imai, Yasushi; Kosaka, Akio; Delaunay, Jean-Jacques; Yamada, Ichiro

    Continuous monitoring of blood pressure in daily life could improve early detection of cardiovascular disorders, as well as promoting healthcare. Conventional ambulatory blood pressure monitoring (ABPM) equipment can measure blood pressure at regular intervals for 24 hours, but is limited by long measuring time, low sampling rate, and constrained measuring posture. In this paper, we demonstrate a new method for continuous real-time measurement of blood pressure during daily activities. Our method is based on blood pressure estimation from pulse wave velocity (PWV) calculation, which formula we improved to take into account changes in the inner diameter of blood vessels. Blood pressure estimation results using our new method showed a greater precision of measured data during exercise, and a better accuracy than the conventional PWV method.

  4. Atmospheric pressure loading effects on Global Positioning System coordinate determinations

    Science.gov (United States)

    Vandam, Tonie M.; Blewitt, Geoffrey; Heflin, Michael B.

    1994-01-01

    Earth deformation signals caused by atmospheric pressure loading are detected in vertical position estimates at Global Positioning System (GPS) stations. Surface displacements due to changes in atmospheric pressure account for up to 24% of the total variance in the GPS height estimates. The detected loading signals are larger at higher latitudes where pressure variations are greatest; the largest effect is observed at Fairbanks, Alaska (latitude 65 deg), with a signal root mean square (RMS) of 5 mm. Out of 19 continuously operating GPS sites (with a mean of 281 daily solutions per site), 18 show a positive correlation between the GPS vertical estimates and the modeled loading displacements. Accounting for loading reduces the variance of the vertical station positions on 12 of the 19 sites investigated. Removing the modeled pressure loading from GPS determinations of baseline length for baselines longer than 6000 km reduces the variance on 73 of the 117 baselines investigated. The slight increase in variance for some of the sites and baselines is consistent with expected statistical fluctuations. The results from most stations are consistent with approximately 65% of the modeled pressure load being found in the GPS vertical position measurements. Removing an annual signal from both the measured heights and the modeled load time series leaves this value unchanged. The source of the remaining discrepancy between the modeled and observed loading signal may be the result of (1) anisotropic effects in the Earth's loading response, (2) errors in GPS estimates of tropospheric delay, (3) errors in the surface pressure data, or (4) annual signals in the time series of loading and station heights. In addition, we find that using site dependent coefficients, determined by fitting local pressure to the modeled radial displacements, reduces the variance of the measured station heights as well as or better than using the global convolution sum.

  5. [The clinical effect of airway pressure release ventilation for acute lung injury/acute respiratory distress syndrome].

    Science.gov (United States)

    Song, Shaohua; Tian, Huiyu; Yang, Xiufen; Hu, Zhenjie

    2016-01-01

    To evaluate the effect of airway pressure release ventilation (APRV) in patients with acute lung injury/acute respiratory distress syndrome (ALI/ARDS), to evaluate the extent of ventilator-induced lung injury (VILI), and to explore its possible mechanism. A prospective study was conducted in the Department of Critical Care Medicine of the First Hospital of Hebei Medical University from December 2010 to February 2012. The patients with ALI/ARDS were enrolled. They were randomly divided into two groups. The patients in APRV group were given APRV pattern, while those in control group were given lung protection ventilation, synchronized intermittent mandatory ventilation with positive end-expiratory pressure (SIMV+PEEP). All patients were treated with AVEA ventilator. The parameters such as airway peak pressure (Ppeak), mean airway pressure (Pmean), pulse oxygen saturation (SpO2), mean arterial pressure (MAP), heart rate (HR), central venous pressure (CVP), arterial blood gas, urine output (UO), the usage of sedation and muscle relaxation drugs were recorded. AVEA ventilator "turning point (Pflex) operation" was used to describe the quasi-static pressure volume curve (P-V curve). High and low inflection point (UIP, LIP) and triangular Pflex volume (Vdelta) were automatically measured and calculated. The ventilation parameters were set, and the 24-hour P-V curve was recorded again in order to be compared with subsequent results. Venous blood was collected before treatment, 24 hours and 48 hours after ventilation to measure lung surfactant protein D (SP-D) and large molecular mucus in saliva (KL-6) by enzyme linked immunosorbent assay (ELISA), and the correlation between the above two parameters and prognosis on 28 days was analyzed by multinomial logistic regression. Twenty-six patients with ALI/ARDS were enrolled, and 22 of them completed the test with 10 in APRV group and 12 in control group. The basic parameters and P-V curves between two groups were similar before

  6. Positive outcome of average volume-assured pressure support mode of a Respironics V60 Ventilator in acute exacerbation of chronic obstructive pulmonary disease: a case report

    Directory of Open Access Journals (Sweden)

    Okuda Miyuki

    2012-09-01

    Full Text Available Abstract Introduction We were able to treat a patient with acute exacerbation of chronic obstructive pulmonary disease who also suffered from sleep-disordered breathing by using the average volume-assured pressure support mode of a Respironics V60 Ventilator (Philips Respironics: United States. This allows a target tidal volume to be set based on automatic changes in inspiratory positive airway pressure. This removed the need to change the noninvasive positive pressure ventilation settings during the day and during sleep. The Respironics V60 Ventilator, in the average volume-assured pressure support mode, was attached to our patient and improved and stabilized his sleep-related hypoventilation by automatically adjusting force to within an acceptable range. Case presentation Our patient was a 74-year-old Japanese man who was hospitalized for treatment due to worsening of dyspnea and hypoxemia. He was diagnosed with acute exacerbation of chronic obstructive pulmonary disease and full-time biphasic positive airway pressure support ventilation was initiated. Our patient was temporarily provided with portable noninvasive positive pressure ventilation at night-time following an improvement in his condition, but his chronic obstructive pulmonary disease again worsened due to the recurrence of a respiratory infection. During the initial exacerbation, his tidal volume was significantly lower during sleep (378.9 ± 72.9mL than while awake (446.5 ± 63.3mL. A ventilator that allows ventilation to be maintained by automatically adjusting the inspiratory force to within an acceptable range was attached in average volume-assured pressure support mode, improving his sleep-related hypoventilation, which is often associated with the use of the Respironics V60 Ventilator. Polysomnography performed while our patient was on noninvasive positive pressure ventilation revealed obstructive sleep apnea syndrome (apnea-hypopnea index = 14, suggesting that his chronic

  7. Continuous bedside pressure mapping and rates of hospital-associated pressure ulcers in a medical intensive care unit.

    Science.gov (United States)

    Behrendt, Robert; Ghaznavi, Amir M; Mahan, Meredith; Craft, Susan; Siddiqui, Aamir

    2014-03-01

    Critically ill patients are vulnerable to the development of hospital-associated pressure ulcers (HAPUs). Positioning of patients is an essential component of pressure ulcer prevention because it off-loads areas of high pressure. However, the effectiveness of such positioning is debatable. A continuous bedside pressure mapping (CBPM) device can provide real-time feedback of optimal body position though a pressure-sensing mat that displays pressure images at a patient's bedside, allowing off-loading of high-pressure areas and possibly preventing HAPU formation. A prospective controlled study was designed to determine if CBPM would reduce the number of HAPUs in patients treated in our medical intensive care unit. In 2 months, 422 patients were enrolled and assigned to beds equipped with or without a CBPM device. Patients' skin was assessed daily and weekly to determine the presence and progress of HAPUs. All patients were turned every 2 hours. CBPM patients were repositioned to off-load high-pressure points during turning, according to a graphic display. The number of newly formed HAPUs was the primary outcome measured. A χ(2) test was then used to compare the occurrence of HAPUs between groups. HAPUs developed in 2 of 213 patients in the CBPM group (0.9%; both stage II) compared with 10 of 209 in the control group (4.8%; all stage II; P = .02). Significantly fewer HAPUs occurred in the CBPM group than the control group, indicating the effectiveness of real-time visual feedback in repositioning of patients to prevent the formation of new HAPUs.

  8. Impact of obstructive sleep apnea on blood pressure in patients with hypertension

    Directory of Open Access Journals (Sweden)

    Gurubhagavatula I

    2011-12-01

    Full Text Available Barry Fields1, Indira Gurubhagavatula1–31Division of Sleep Medicine, Perelman School of Medicine, University of Pennsylvania, 2Center for Sleep and Circadian Neurobiology, Perelman School of Medicine, University of Pennsylvania, 3Philadelphia VA Medical Center, Philadelphia, Pennsylvania, USAAbstract: Hypertension is the most significant risk factor for death worldwide. Approximately 30%–40% of affected individuals have coexisting obstructive sleep apnea (OSA, a disorder resulting from the upper airway’s inability to remain patent during sleep. A causal relationship between OSA and hypertension has been demonstrated. Blunting or elimination of normal blood pressure (BP dipping during sleep is commonly seen in OSA patients, with corresponding increases in daytime BP. This dipping is clinically salient, because it is associated with the end-organ damage seen with chronic hypertension, such as cardiovascular, renal, and cerebrovascular disease. African-Americans are at greatest risk for non-dipping and end-organ damage. Rapidly fluctuating changes in sympathetic tone, intrathoracic pressure, oxyhemoglobin saturation, and carbon dioxide levels are all thought to play a role in acute and chronic BP elevation. Individuals with preexisting hypertension are most susceptible to OSA’s BP-raising effects. First-line therapy for OSA includes continuous positive airway pressure (CPAP delivered via a mask interface. Patients who show the greatest BP declines while using CPAP are more likely to be those who have at least moderate OSA, adhere to therapy, have preexisting hypertension, and whose blood vessels retain reversibility in disease-related remodeling. Given the heavy burden OSA-related hypertension places on the healthcare system, prevention, early detection, and prompt intervention should be the goals for all affected individuals.Keywords: obstructive sleep apnea (OSA, hypertension, nocturnal dipping, continuous positive airway pressure (CPAP

  9. Position paper by Canadian dental sleep medicine professionals regarding the role of different health care professionals in managing obstructive sleep apnea and snoring with oral appliances

    OpenAIRE

    Gauthier, Luc; Almeida, Fernanda; Arcache, Patrick; Ashton-McGregor, Catherine; Côté, David; Driver, Helen; Ferguson, Kathleen; Lavigne, Gilles; Martin, Philippe; Masse, Jean-François; Morisson, Florence; Pancer, Jeffrey; Samuels, Charles; Schachter, Maurice; Sériès, Frédéric

    2012-01-01

    The present Canadian position paper contains recommendations for the management by dentists of sleep-disordered breathing in adults with the use of oral appliances (OAs) as a treatment option for snoring and obstructive sleep apnea (OSA). The recommendations are based on literature reviews and expert panel consensus. OAs offer an effective, first-line treatment option for patients with mild to moderate OSA who prefer an OA to continuous positive airway pressure (CPAP) therapy, or for severe O...

  10. The position of the arm during blood pressure measurement in sitting position.

    Science.gov (United States)

    Adiyaman, Ahmet; Verhoeff, Rutger; Lenders, Jacques W M; Deinum, Jaap; Thien, Theo

    2006-12-01

    Determining the influence of the position of the arm on blood pressure measurement in the sitting position. Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in two different positions. First, both arms were placed at the chair support level and blood pressure was measured three times on both arms after 10 min of rest. Subsequently, while still remaining in the same sitting position, five blood pressure measurements were made simultaneously at both arms with one arm placed on the desk and one arm placed and supported at heart level (mid-sternal). The arm placed at heart level served as the reference arm. The choice of which arm was placed at desk level and which arm was placed at heart level was randomized. Both at desk level and at chair support level, mean (+/-SD) systolic and diastolic blood pressures were higher than blood pressure at heart level by 6.1/5.7+/-4.6/3.1 and 9.3/9.4+/-5.4/3.4 mmHg, respectively. The effect of the height differences between the arm positions on the blood pressure readings was smaller than predicted (0.49 mmHg/cm systolic and 0.47 mmHg/cm diastolic). No significant correlation was found between blood pressure difference in the different arm positions (desk and heart level) and age, sex, weight or baseline blood pressure. Different arm positions below heart level have significant effects on blood pressure readings. The leading guidelines about arm position during blood pressure measurement are not in accordance with the arm position used in the Framingham study, the most frequently used study for risk estimations.

  11. Atopic asthmatic immune phenotypes associated with airway microbiota and airway obstruction.

    Directory of Open Access Journals (Sweden)

    Benjamin A Turturice

    Full Text Available Differences in asthma severity may be related to inflammation in the airways. The lower airway microbiota has been associated with clinical features such as airway obstruction, symptom control, and response to corticosteroids.To assess the relationship between local airway inflammation, severity of disease, and the lower airway microbiota in atopic asthmatics.A cohort of young adult, atopic asthmatics with intermittent or mild/moderate persistent symptoms (n = 13 were assessed via bronchoscopy, lavage, and spirometry. These individuals were compared to age matched non-asthmatic controls (n = 6 and to themselves after six weeks of treatment with fluticasone propionate (FP. Inflammation of the airways was assessed via a cytokine and chemokine panel. Lower airway microbiota composition was determined by metagenomic shotgun sequencing.Unsupervised clustering of cytokines and chemokines prior to treatment with FP identified two asthmatic phenotypes (AP, termed AP1 and AP2, with distinct bronchoalveolar lavage inflammatory profiles. AP2 was associated with more obstruction, compared to AP1. After treatment with FP reduced MIP-1β and TNF-α and increased IL-2 was observed. A module of highly correlated cytokines that include MIP-1β and TNF-α was identified that negatively correlated with pulmonary function. Independently, IL-2 was positively correlated with pulmonary function. The airway microbiome composition correlated with asthmatic phenotypes. AP2, prior to FP treatment, was enriched with Streptococcus pneumoniae. Unique associations between IL-2 or the cytokine module and the microbiota composition of the airways were observed in asthmatics subjects prior to treatment but not after or in controls.The underlying inflammation in atopic asthma is related to the composition of microbiota and is associated with severity of airway obstruction. Treatment with inhaled corticosteroids was associated with changes in the airway inflammatory response to

  12. Simulation of late inspiratory rise in airway pressure during pressure support ventilation.

    Science.gov (United States)

    Yu, Chun-Hsiang; Su, Po-Lan; Lin, Wei-Chieh; Lin, Sheng-Hsiang; Chen, Chang-Wen

    2015-02-01

    Late inspiratory rise in airway pressure (LIRAP, Paw/ΔT) caused by inspiratory muscle relaxation or expiratory muscle contraction is frequently seen during pressure support ventilation (PSV), although the modulating factors are unknown. We investigated the effects of respiratory mechanics (normal, obstructive, restrictive, or mixed), inspiratory effort (-2, -8, or -15 cm H2O), flow cycle criteria (5-40% peak inspiratory flow), and duration of inspiratory muscle relaxation (0.18-0.3 s) on LIRAP during PSV using a lung simulator and 4 types of ventilators. LIRAP occurred with all lung models when inspiratory effort was medium to high and duration of inspiratory muscle relaxation was short. The normal lung model was associated with the fastest LIRAP, whereas the obstructive lung model was associated with the slowest. Unless lung mechanics were normal or mixed, LIRAP was unlikely to occur when inspiratory effort was low. Different ventilators were also associated with differences in LIRAP speed. Except for within the restrictive lung model, changes in flow cycle level did not abolish LIRAP if inspiratory effort was medium to high. Increased duration of inspiratory relaxation also led to the elimination of LIRAP. Simulation of expiratory muscle contraction revealed that LIRAP occurred only when expiratory muscle contraction occurred sometime after the beginning of inspiration. Our simulation study reveals that both respiratory resistance and compliance may affect LIRAP. Except for under restrictive lung conditions, LIRAP is unlikely to be abolished by simply lowering flow cycle criteria when inspiratory effort is strong and relaxation time is rapid. LIRAP may be caused by expiratory muscle contraction when it occurs during inspiration. Copyright © 2015 by Daedalus Enterprises.

  13. Videolaryngoscopy versus Fiber-optic Intubation through a Supraglottic Airway in Children with a Difficult Airway: An Analysis from the Multicenter Pediatric Difficult Intubation Registry.

    Science.gov (United States)

    Burjek, Nicholas E; Nishisaki, Akira; Fiadjoe, John E; Adams, H Daniel; Peeples, Kenneth N; Raman, Vidya T; Olomu, Patrick N; Kovatsis, Pete G; Jagannathan, Narasimhan; Hunyady, Agnes; Bosenberg, Adrian; Tham, See; Low, Daniel; Hopkins, Paul; Glover, Chris; Olutoye, Olutoyin; Szmuk, Peter; McCloskey, John; Dalesio, Nicholas; Koka, Rahul; Greenberg, Robert; Watkins, Scott; Patel, Vikram; Reynolds, Paul; Matuszczak, Maria; Jain, Ranu; Khalil, Samia; Polaner, David; Zieg, Jennifer; Szolnoki, Judit; Sathyamoorthy, Kumar; Taicher, Brad; Riveros Perez, N Ricardo; Bhattacharya, Solmaletha; Bhalla, Tarun; Stricker, Paul; Lockman, Justin; Galvez, Jorge; Rehman, Mohamed; Von Ungern-Sternberg, Britta; Sommerfield, David; Soneru, Codruta; Chiao, Franklin; Richtsfeld, Martina; Belani, Kumar; Sarmiento, Lina; Mireles, Sam; Bilen Rosas, Guelay; Park, Raymond; Peyton, James

    2017-09-01

    The success rates and related complications of various techniques for intubation in children with difficult airways remain unknown. The primary aim of this study is to compare the success rates of fiber-optic intubation via supraglottic airway to videolaryngoscopy in children with difficult airways. Our secondary aim is to compare the complication rates of these techniques. Observational data were collected from 14 sites after management of difficult pediatric airways. Patient age, intubation technique, success per attempt, use of continuous ventilation, and complications were recorded for each case. First-attempt success and complications were compared in subjects managed with fiber-optic intubation via supraglottic airway and videolaryngoscopy. Fiber-optic intubation via supraglottic airway and videolaryngoscopy had similar first-attempt success rates (67 of 114, 59% vs. 404 of 786, 51%; odds ratio 1.35; 95% CI, 0.91 to 2.00; P = 0.16). In subjects less than 1 yr old, fiber-optic intubation via supraglottic airway was more successful on the first attempt than videolaryngoscopy (19 of 35, 54% vs. 79 of 220, 36%; odds ratio, 2.12; 95% CI, 1.04 to 4.31; P = 0.042). Complication rates were similar in the two groups (20 vs. 13%; P = 0.096). The incidence of hypoxemia was lower when continuous ventilation through the supraglottic airway was used throughout the fiber-optic intubation attempt. In this nonrandomized study, first-attempt success rates were similar for fiber-optic intubation via supraglottic airway and videolaryngoscopy. Fiber-optic intubation via supraglottic airway is associated with higher first-attempt success than videolaryngoscopy in infants with difficult airways. Continuous ventilation through the supraglottic airway during fiber-optic intubation attempts may lower the incidence of hypoxemia.

  14. Early treatment of idiopathic respiratory distress syndrome using binasal continuous positive airway pressure

    DEFF Research Database (Denmark)

    Kamper, J; Ringsted, C

    1990-01-01

    out of 25 infants with a birth weight less than or equal to 1500 g and in 53 out of 60 infants with a birth weight greater than 1500 g. Seven infants developed pneumothorax during CPAP treatment. Seventy-four infants survived, all without bronchopulmonary dysplasia. At the age of 1.5-4.5 years...

  15. Optimal level of continuous positive airway pressure: Auto-CPAP titration versus predictive formulas

    Directory of Open Access Journals (Sweden)

    Nashwa Abdel Wahab

    2017-04-01

    Conclusions: Predictive formulas might be useful as an alternative to autoCPAP. The model of predictive formula derived from the present small sample of Egyptian patients with OSAHS should be validated on a larger sample size.

  16. Extraglottic airway devices: technology update

    Directory of Open Access Journals (Sweden)

    Sharma B

    2017-08-01

    Full Text Available Bimla Sharma, Chand Sahai, Jayashree Sood Department of Anaesthesiology, Pain and Perioperative Medicine, Sir Ganga Ram Hospital, New Delhi, India Abstract: Extraglottic airway devices (EADs have revolutionized the field of airway management. The invention of the laryngeal mask airway was a game changer, and since then, there have been several innovations to improve the EADs in design, functionality, safety and construction material. These have ranged from changes in the shape of the mask, number of cuffs and material used, like rubber, polyvinylchloride and latex. Phthalates, which were added to the construction material in order to increase device flexibility, were later omitted when this chemical was found to have serious adverse reproductive outcomes. The various designs brought out by numerous companies manufacturing EADs resulted in the addition of several devices to the airway market. These airway devices were put to use, many of them with inadequate or no evidence base regarding their efficacy and safety. To reduce the possibility of compromising the safety of the patient, the Difficult Airway Society (DAS formed the Airway Device Evaluation Project Team (ADEPT to strengthen the evidence base for airway equipment and vet the new extraglottic devices. A preuse careful analysis of the design and structure may help in better understanding of the functionality of a particular device. In the meantime, the search for the ideal EAD continues. Keywords: extraglottic airway devices, laryngeal mask airway, other extraglottic airway devices, safety, technology update

  17. Advantages, Disadvantages, Indications, Contraindications and Surgical Technique of Laryngeal Airway Mask.

    Science.gov (United States)

    Jannu, Anubhav; Shekar, Ashim; Balakrishna, Ramdas; Sudarshan, H; Veena, G C; Bhuvaneshwari, S

    2017-12-01

    The beauty of the laryngeal mask is that it forms an air tight seal enclosing the larynx rather than plugging the pharynx, and avoid airway obstruction in the oropharynx. The goal of its development was to create an intermediate form of airway management face mask and endotracheal tube. Indication for its use includes any procedure that would normally involve the use of a face mask. The laryngeal mask airway was designed as a new concept in airway management and has been gaining a firm position in anesthetic practice. Despite wide spread use the definitive role of the laryngeal mask airway is yet to be established. In some situations, such as after failed tracheal intubation or in oral surgery its use is controversial. There are several unresolved issues, for example the effect of the laryngeal mask on regurgitation and whether or not cricoids pressure prevents placement of mask. We review the techniques of insertion, details of misplacement, and complications associated with use of the laryngeal mask. We then attempt to clarify the role of laryngeal mask in air way management during anesthesia, discussing the advantages and disadvantages as well as indications and contraindications of its use in oral and maxillofacial surgery.

  18. Noninvasive positive pressure ventilation in acute asthmatic attack

    Directory of Open Access Journals (Sweden)

    A. Soroksky

    2010-03-01

    Full Text Available Asthma is characterised by reversible airway obstruction. In most patients, control of disease activity is easily achieved. However, in a small minority, asthma may be fatal. Between the two extremes lie patients with severe asthmatic attacks, refractory to standard treatment. These patients are at an increased risk of recurrent severe attacks, with respiratory failure, and mechanical ventilation. Invasive mechanical ventilation of the asthmatic patient is associated with a higher risk of complications and, therefore, is a measure of last resort. Noninvasive positive pressure ventilation (NPPV is another treatment modality that may be beneficial in patients with severe asthmatic attack who are at an increased risk of developing respiratory failure. These patients have the potential to benefit from early respiratory support in the form of NPPV. However, reports of NPPV in asthmatic patients are scarce, and its usage in asthmatic attacks is, therefore, still controversial. Only a few reports of NPPV in asthma have been published over the last decade. These studies mostly involve small numbers of patients and those who have problematic methodology. In this article we review the available evidence for NPPV in asthma and try to formulate our recommendations for NPPV application in asthma based on the available evidence and reports.

  19. Effects of Depth of Propofol and Sevoflurane Anesthesia on Upper Airway Collapsibility, Respiratory Genioglossus Activation, and Breathing in Healthy Volunteers

    DEFF Research Database (Denmark)

    Simons, Jeroen C P; Pierce, Eric; Diaz-Gil, Daniel

    2016-01-01

    . Measurements included bispectral index, genioglossus electromyography, ventilation, hypopharyngeal pressure, upper airway closing pressure, and change in end-expiratory lung volume during mask pressure drops. RESULTS: A total of 393 attempted breaths during occlusion maneuvers were analyzed. Upper airway......BACKGROUND: Volatile anesthetics and propofol impair upper airway stability and possibly respiratory upper airway dilator muscle activity. The magnitudes of these effects have not been compared at equivalent anesthetic doses. We hypothesized that upper airway closing pressure is less negative...... closing pressure was significantly less negative at deep versus shallow anesthesia (-10.8 ± 4.5 vs. -11.3 ± 4.4 cm H2O, respectively [mean ± SD]) and correlated with the bispectral index (P airway at deep anesthesia. Respiratory genioglossus activity during airway...

  20. Prediction of high airway pressure using a non-linear autoregressive model of pulmonary mechanics.

    Science.gov (United States)

    Langdon, Ruby; Docherty, Paul D; Schranz, Christoph; Chase, J Geoffrey

    2017-11-02

    For mechanically ventilated patients with acute respiratory distress syndrome (ARDS), suboptimal PEEP levels can cause ventilator induced lung injury (VILI). In particular, high PEEP and high peak inspiratory pressures (PIP) can cause over distension of alveoli that is associated with VILI. However, PEEP must also be sufficient to maintain recruitment in ARDS lungs. A lung model that accurately and precisely predicts the outcome of an increase in PEEP may allow dangerous high PIP to be avoided, and reduce the incidence of VILI. Sixteen pressure-flow data sets were collected from nine mechanically ventilated ARDs patients that underwent one or more recruitment manoeuvres. A nonlinear autoregressive (NARX) model was identified on one or more adjacent PEEP steps, and extrapolated to predict PIP at 2, 4, and 6 cmH 2 O PEEP horizons. The analysis considered whether the predicted and measured PIP exceeded a threshold of 40 cmH 2 O. A direct comparison of the method was made using the first order model of pulmonary mechanics (FOM(I)). Additionally, a further, more clinically appropriate method for the FOM was tested, in which the FOM was trained on a single PEEP prior to prediction (FOM(II)). The NARX model exhibited very high sensitivity (> 0.96) in all cases, and a high specificity (> 0.88). While both FOM methods had a high specificity (> 0.96), the sensitivity was much lower, with a mean of 0.68 for FOM(I), and 0.82 for FOM(II). Clinically, false negatives are more harmful than false positives, as a high PIP may result in distension and VILI. Thus, the NARX model may be more effective than the FOM in allowing clinicians to reduce the risk of applying a PEEP that results in dangerously high airway pressures.

  1. Practice parameters for the surgical modifications of the upper airway for obstructive sleep apnea in adults.

    Science.gov (United States)

    Aurora, R Nisha; Casey, Kenneth R; Kristo, David; Auerbach, Sanford; Bista, Sabin R; Chowdhuri, Susmita; Karippot, Anoop; Lamm, Carin; Ramar, Kannan; Zak, Rochelle; Morgenthaler, Timothy I

    2010-10-01

    Practice parameters for the treatment of obstructive sleep apnea syndrome (OSAS) in adults by surgical modification of the upper airway were first published in 1996 by the American Academy of Sleep Medicine (formerly ASDA). The following practice parameters update the previous practice parameters. These recommendations were reviewed and approved by the Board of Directors of the American Academy of Sleep Medicine. A systematic review of the literature was performed, and the GRADE system was used to assess the quality of evidence. The findings from this evaluation are provided in the accompanying review paper, and the subsequent recommendations have been developed from this review. The following procedures have been included: tracheostomy, maxillo-mandibular advancement (MMA), laser assisted uvulopalatoplasty (LAUP), uvulopalatopharyngoplasty (UPPP), radiofrequency ablation (RFA), and palatal implants. The presence and severity of obstructive sleep apnea must be determined before initiating surgical therapy (Standard). The patient should be advised about potential surgical success rates and complications, the availability of alternative treatment options such as nasal positive airway pressure and oral appliances, and the levels of effectiveness and success rates of these alternative treatments (Standard). The desired outcomes of treatment include resolution of the clinical signs and symptoms of obstructive sleep apnea and the normalization of sleep quality, the apnea-hypopnea index, and oxyhemoglobin saturation levels (Standard). Tracheostomy has been shown to be an effective single intervention to treat obstructive sleep apnea. This operation should be considered only when other options do not exist, have failed, are refused, or when this operation is deemed necessary by clinical urgency (Option). MMA is indicated for surgical treatment of severe OSA in patients who cannot tolerate or who are unwilling to adhere to positive airway pressure therapy, or in whom oral

  2. [Difficult Ventilation Requiring Emergency Endotracheal Intubation during Awake Craniotomy Managed by Laryngeal Mask Airway].

    Science.gov (United States)

    Matsuda, Asako; Mizota, Toshiyuki; Tanaka, Tomoharu; Segawa, Hajime; Fukuda, Kazuhiko

    2016-04-01

    We report a case of difficult ventilation requiring emergency endotracheal intubation during awake craniotomy managed by laryngeal mask airway (LMA). A 45-year-old woman was scheduled to receive awake craniotomy for brain tumor in the frontal lobe. After anesthetic induction, airway was secured using ProSeal LMA and patient was mechanically ventilated in pressure-control mode. Patient's head was fixed with head-pins at anteflex position, and the operation started. About one hour after the start of the operation, tidal volume suddenly decreased. We immediately started manual ventilation, but the airway resistance was extremely high and we could not adequately ventilate the patient. We administered muscle relaxant for suspected laryngospasm, but ventilatory status did not improve; so we decided to conduct emergency endotracheal intubation. We tried to intubate using Airwayscope or LMA-Fastrach, but they were not effective in our case. Finally trachea was intubated using transnasal fiberoptic bronchoscopy. We discuss airway management during awake craniotomy, focusing on emergency endotracheal intubation during surgery.

  3. Management of Obstructive Sleep Apnea

    Directory of Open Access Journals (Sweden)

    V K Vijayan

    2014-03-01

    Full Text Available Obstructive Sleep Apnea (OSA is an important public health problem and is associatedwith considerable morbidity and mortality. Therefore, treatment of this condition is ofparamount importance. The treatment of OSA includes general and behaviouralmeasures, mechanical measures including continuous positive airway pressure(CPAP, Bilevel positive airway pressure (BiPAP and Oral Appliances (OA,pharmacological treatment and surgical procedures. Continuous positive airwaypressure (CPAP treatment reverses the repetitive upper airway obstruction of sleepapnea and associated daytime sleepiness and is the most effective treatment for OSA.However maintaining patient adherence to CPAP therapy is a challenge. Weight lossshould be recommended to overweight patients with OSA, as it has been shown thatweight reduction has additional health benefits. Treatment of underlying medicalconditions such as hypothyroidism or acromegaly has profound effect onapnea/hypopnea index. A subset of patients with OSA may benefit from supplementaloxygen and positional therapy. Presently, there are no effective pharmacotherapeuticagents for treatment of patients with OSA and the role of surgical treatment in OSA iscontroversial. However, pharmacological treatment of persisting residual sleepiness,despite adequate positive airway pressure therapy delivery and adherence, is indicatedand may improve daytime sleepiness.Key words : CPAP, Oral appliances, Modafinil, CPAP complianceUvulopalatopharyngoplasty, positional therapy

  4. Optimal degree of mouth opening for laryngeal mask airway function during oral surgery.

    Science.gov (United States)

    Sanuki, Takuro; Sugioka, Shingo; Hirokane, Motoko; Son, Hiroki; Uda, Rumiko; Akatsuka, Masafumi; Kotani, Junichiro

    2011-04-01

    This study was performed to determine the optimal degree of mouth opening in anesthetized patients requiring laryngeal mask airway (LMA) during oral surgery. A single, experienced LMA user inserted the LMA in 15 patients who were scheduled for elective oral surgery. Oropharyngeal leak pressure, intracuff pressure, and fiberoptic assessment of the LMA position were sequentially documented in 5 mouth conditions-opening of 1.4 (neutral position), 2, 3, 4, and 5 cm-and any resulting ventilatory difficulties were recorded. Oropharyngeal leak pressure with the mouth open 4 cm (21.8 ± 3.2 cm H(2)O, P = .025) and 5 cm (27.3 ± 7.2 cm H(2)O, P Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. High Flow Nasal Cannula Therapy for Improving Obstructive Sleep Apnea: A Case Report

    Directory of Open Access Journals (Sweden)

    Se Joong Kim

    2015-06-01

    Full Text Available Although continuous positive airway pressure is the treatment of choice for obstructive sleep apnea, its compliance is low. Therefore, alternative therapeutic strategies are often required. High flow nasal cannula therapy uses an air compressor to deliver a constant flow of oxygen via the nasal cannula at a maximum of 60 L/m. It can produce positive end expiratory pressure and increase end expiratory pharyngeal pressure, which can help to alleviate upper airway obstruction. This is a case report of high flow nasal cannula therapy for a 71 year-old man. He had an obstructive sleep apnea and severe desaturation but failed to use continuous positive airway pressure. He underwent titration with high flow nasal cannula under polysomnography. Using high flow nasal cannula at an airflow of 45 L/m, his apnea-hypopnea, respiratory arousal and oxygen desaturation were improved. Importantly, he is very compliant with high flow nasal cannula therapy.

  6. Innovative treatments for adults with obstructive sleep apnea

    Directory of Open Access Journals (Sweden)

    Weaver TE

    2014-11-01

    Full Text Available Terri E Weaver,1,2 Michael W Calik,1,2 Sarah S Farabi,1,2 Anne M Fink,1,2 Maria T Galang-Boquiren,2,3 Mary C Kapella,1,2 Bharati Prasad,2,4 David W Carley1,21Biobehavioral Health Science Department, College of Nursing, University of Illinois at Chicago; 2Center for Narcolepsy, Sleep and Health, University of Illinois at Chicago College of Nursing, 3Department of Orthodontics, University of Illinois at Chicago College of Dentistry, 4Sleep Center, Department of Medicine, University of Illinois at Chicago College of Medicine, Chicago, IL, USAAbstract: Obstructive sleep apnea (OSA affects one in five adult males and is associated with significant comorbidity, cognitive impairment, excessive daytime sleepiness, and reduced quality of life. For over 25 years, the primary treatment has been continuous positive airway pressure, which introduces a column of air that serves as a pneumatic splint for the upper airway, preventing the airway collapse that is the physiologic definition of this syndrome. However, issues with patient tolerance and unacceptable levels of treatment adherence motivated the exploration of other potential treatments. With greater understanding of the physiologic mechanisms associated with OSA, novel interventions have emerged in the last 5 years. The purpose of this article is to describe new treatments for OSA and associated complex sleep apnea. New approaches to complex sleep apnea have included adaptive servoventilation. There is increased literature on the contribution of behavioral interventions to improve adherence with continuous positive airway pressure that have proven quite effective. New non-surgical treatments include oral pressure devices, improved mandibular advancement devices, nasal expiratory positive airway pressure, and newer approaches to positional therapy. Recent innovations in surgical interventions have included laser-assisted uvulopalatoplasty, radiofrequency ablation, palatal implants, and electrical

  7. Positive expiratory pressure - Common clinical applications and physiological effects.

    Science.gov (United States)

    Fagevik Olsén, Monika; Lannefors, Louise; Westerdahl, Elisabeth

    2015-03-01

    Breathing out against resistance, in order to achieve positive expiratory pressure (PEP), is applied by many patient groups. Pursed lips breathing and a variety of devices can be used to create the resistance giving the increased expiratory pressure. Effects on pulmonary outcomes have been discussed in several publications, but the expected underlying physiology of the effect is seldom discussed. The aim of this article is to describe the purpose, performance, clinical application and underlying physiology of PEP when it is used to increase lung volumes, decrease hyperinflation or improve airway clearance. In clinical practice, the instruction how to use an expiratory resistance is of major importance since it varies. Different breathing patterns during PEP increase or reduce expiratory flow, result in movement of EPP centrally or peripherally and can increase or decrease lung volume. It is therefore necessary to give the right instructions to obtain the desired effects. As the different PEP techniques are being used by diverse patient groups it is not possible to give standard instructions. Based on the information given in this article the instructions have to be adjusted to give the optimal effect. There is no consensus regarding optimal treatment frequency and number of cycles included in each treatment session and must also be individualized. In future research, more precise descriptions are needed about physiological aims and specific instructions of how the treatments have been performed to assure as good treatment quality as possible and to be able to evaluate and compare treatment effects. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Higher levels of spontaneous breathing reduce lung injury in experimental moderate acute respiratory distress syndrome.

    Science.gov (United States)

    Carvalho, Nadja C; Güldner, Andreas; Beda, Alessandro; Rentzsch, Ines; Uhlig, Christopher; Dittrich, Susanne; Spieth, Peter M; Wiedemann, Bärbel; Kasper, Michael; Koch, Thea; Richter, Torsten; Rocco, Patricia R; Pelosi, Paolo; de Abreu, Marcelo Gama

    2014-11-01

    To assess the effects of different levels of spontaneous breathing during biphasic positive airway pressure/airway pressure release ventilation on lung function and injury in an experimental model of moderate acute respiratory distress syndrome. Multiple-arm randomized experimental study. University hospital research facility. Thirty-six juvenile pigs. Pigs were anesthetized, intubated, and mechanically ventilated. Moderate acute respiratory distress syndrome was induced by repetitive saline lung lavage. Biphasic positive airway pressure/airway pressure release ventilation was conducted using the airway pressure release ventilation mode with an inspiratory/expiratory ratio of 1:1. Animals were randomly assigned to one of four levels of spontaneous breath in total minute ventilation (n = 9 per group, 6 hr each): 1) biphasic positive airway pressure/airway pressure release ventilation, 0%; 2) biphasic positive airway pressure/airway pressure release ventilation, > 0-30%; 3) biphasic positive airway pressure/airway pressure release ventilation, > 30-60%, and 4) biphasic positive airway pressure/airway pressure release ventilation, > 60%. The inspiratory effort measured by the esophageal pressure time product increased proportionally to the amount of spontaneous breath and was accompanied by improvements in oxygenation and respiratory system elastance. Compared with biphasic positive airway pressure/airway pressure release ventilation of 0%, biphasic positive airway pressure/airway pressure release ventilation more than 60% resulted in lowest venous admixture, as well as peak and mean airway and transpulmonary pressures, redistributed ventilation to dependent lung regions, reduced the cumulative diffuse alveolar damage score across lungs (median [interquartile range], 11 [3-40] vs 18 [2-69]; p ventilation more than 0-30% and more than 30-60% showed a less consistent pattern of improvement in lung function, inflammation, and damage compared with biphasic positive airway

  9. Relapsing polychondritis and airway involvement.

    Science.gov (United States)

    Ernst, Armin; Rafeq, Samaan; Boiselle, Phillip; Sung, Arthur; Reddy, Chakravarthy; Michaud, Gaetane; Majid, Adnan; Herth, Felix J F; Trentham, David

    2009-04-01

    To assess the prevalence and characteristics of airway involvement in relapsing polychondritis (RP). Retrospective chart review and data analysis of RP patients seen in the Rheumatology Clinic and the Complex Airway Center at Beth Israel Deaconess Medical Center from January 2004 through February 2008. RP was diagnosed in 145 patients. Thirty-one patients had airway involvement, a prevalence of 21%. Twenty-two patients were women (70%), and they were between 11 and 61 years of age (median age, 42 years) at the time of first symptoms. Airway symptoms were the first manifestation of disease in 17 patients (54%). Dyspnea was the most common symptom in 20 patients (64%), followed by cough, stridor, and hoarseness. Airway problems included the following: subglottic stenosis (n = 8; 26%); focal and diffuse malacia (n = 15; 48%); and focal stenosis in different areas of the bronchial tree in the rest of the patients. Twelve patients (40%) required and underwent intervention including balloon dilatation, stent placement, tracheotomy, or a combination of the above with good success. The majority of patients experienced improvement in airway symptoms after intervention. One patient died during the follow-up period from the progression of airway disease. The rest of the patients continue to undergo periodic evaluation and intervention. In this largest cohort described in the English language literature, we found symptomatic airway involvement in RP to be common and at times severe. The nature of airway problems is diverse, with tracheomalacia being the most common. Airway intervention is frequently required and in experienced hands results in symptom improvement.

  10. Chest physiotherapy with positive expiratory pressure breathing after abdominal and thoracic surgery: a systematic review.

    Science.gov (United States)

    Orman, J; Westerdahl, E

    2010-03-01

    A variety of chest physiotherapy techniques are used following abdominal and thoracic surgery to prevent or reduce post-operative complications. Breathing techniques with a positive expiratory pressure (PEP) are used to increase airway pressure and improve pulmonary function. No systematic review of the effects of PEP in surgery patients has been performed previously. The purpose of this systematic review was to determine the effect of PEP breathing after an open upper abdominal or thoracic surgery. A literature search of randomised-controlled trials (RCT) was performed in five databases. The trials included were systematically reviewed by two independent observers and critically assessed for methodological quality. We selected six RCT evaluating the PEP technique performed with a mechanical device in spontaneously breathing adult patients after abdominal or thoracic surgery via thoracotomy. The methodological quality score varied between 4 and 6 on the Physiotherapy Evidence Database score. The studies were published between 1979 and 1993. Only one of the included trials showed any positive effects of PEP compared to other breathing techniques. Today, there is scarce scientific evidence that PEP treatment is better than other physiotherapy breathing techniques in patients undergoing abdominal or thoracic surgery. There is a lack of studies investigating the effect of PEP over placebo or no physiotherapy treatment.

  11. a Continuous-Time Positive Linear System

    Directory of Open Access Journals (Sweden)

    Kyungsup Kim

    2013-01-01

    Full Text Available This paper discusses a computational method to construct positive realizations with sparse matrices for continuous-time positive linear systems with multiple complex poles. To construct a positive realization of a continuous-time system, we use a Markov sequence similar to the impulse response sequence that is used in the discrete-time case. The existence of the proposed positive realization can be analyzed with the concept of a polyhedral convex cone. We provide a constructive algorithm to compute positive realizations with sparse matrices of some positive systems under certain conditions. A sufficient condition for the existence of a positive realization, under which the proposed constructive algorithm works well, is analyzed.

  12. Elective use of the Ventrain for upper airway obstruction during high-frequency jet ventilation.

    Science.gov (United States)

    Fearnley, Robert A; Badiger, Sheela; Oakley, Richard J; Ahmad, Imran

    2016-09-01

    The safety of high pressure source ventilation (jet ventilation) is dependent upon upper airway patency to facilitate adequate passive expiration and prevent increasing intrathoracic pressure and its associated deleterious sequelae. Distortions in airway anatomy may make passive expiration inadequate or impossible in some patients. We report the elective use of the Ventrain device to provide ventilation in a clinical setting of upper airway obstruction in a patient with post radiation fibrosis that had previously prevented passive expiration during attempted high pressure source ventilation. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. A Continuous Quality Improvement Airway Program Results in Sustained Increases in Intubation Success.

    Science.gov (United States)

    Olvera, David J; Stuhlmiller, David F E; Wolfe, Allen; Swearingen, Charles F; Pennington, Troy; Davis, Daniel P

    2018-02-21

    Airway management is a critical skill for air medical providers, including the use of rapid sequence intubation (RSI) medications. Mediocre success rates and a high incidence of complications has challenged air medical providers to improve training and performance improvement efforts to improve clinical performance. The aim of this research was to describe the experience with a novel, integrated advanced airway management program across a large air medical company and explore the impact of the program on improvement in RSI success. The Helicopter Advanced Resuscitation Training (HeART) program was implemented across 160 bases in 2015. The HeART program includes a novel conceptual framework based on thorough understanding of physiology, critical thinking using a novel algorithm, difficult airway predictive tools, training in the optimal use of specific airway techniques and devices, and integrated performance improvement efforts to address opportunities for improvement. The C-MAC video/direct laryngoscope and high-fidelity human patient simulation laboratories were implemented during the study period. Chi-square test for trend was used to evaluate for improvements in airway management and RSI success (overall intubation success, first-attempt success, first-attempt success without desaturation) over the 25-month study period following HeART implementation. A total of 5,132 patients underwent RSI during the study period. Improvements in first-attempt intubation success (85% to 95%, p improving RSI intubation performance in a large air medical company.

  14. Rule-based detection of intrathoracic airway trees

    International Nuclear Information System (INIS)

    Sonka, M.; Park, W.; Hoffman, E.A.

    1996-01-01

    New sensitive and reliable methods for assessing alterations in regional lung structure and function are critically important for the investigation and treatment of pulmonary diseases. Accurate identification of the airway tree will provide an assessment of airway structure and will provide a means by which multiple volumetric images of the lung at the same lung volume over time can be used to assess regional parenchymal changes. The authors describe a novel rule-based method for the segmentation of airway trees from three-dimensional (3-D) sets of computed tomography (CT) images, and its validation. The presented method takes advantage of a priori anatomical knowledge about pulmonary airway and vascular trees and their interrelationships. The method is based on a combination of 3-D seeded region growing that is used to identify large airways, rule-based two-dimensional (2-D) segmentation of individual CT slices to identify probable locations of smaller diameter airways, and merging of airway regions across the 3-D set of slices resulting in a tree-like airway structure. The method was validated in 40 3-mm-thick CT sections from five data sets of canine lungs scanned via electron beam CT in vivo with lung volume held at a constant pressure. The method's performance was compared with that of the conventional 3-D region growing method. The method substantially outperformed an existing conventional approach to airway tree detection

  15. Phosphotyrosine phosphatase and tyrosine kinase inhibition modulate airway pressure-induced lung injury.

    Science.gov (United States)

    Parker, J C; Ivey, C L; Tucker, A

    1998-11-01

    We determined whether drugs which modulate the state of protein tyrosine phosphorylation could alter the threshold for high airway pressure-induced microvascular injury in isolated perfused rat lungs. Lungs were ventilated for successive 30-min periods with peak inflation pressures (PIP) of 7, 20, 30, and 35 cmH2O followed by measurement of the capillary filtration coefficient (Kfc), a sensitive index of hydraulic conductance. In untreated control lungs, Kfc increased by 1.3- and 3.3-fold relative to baseline (7 cmH2O PIP) after ventilation with 30 and 35 cmH2O PIP. However, in lungs treated with 100 microM phenylarsine oxide (a phosphotyrosine phosphatase inhibitor), Kfc increased by 4.7- and 16.4-fold relative to baseline at these PIP values. In lungs treated with 50 microM genistein (a tyrosine kinase inhibitor), Kfc increased significantly only at 35 cmH2O PIP, and the three groups were significantly different from each other. Thus phosphotyrosine phosphatase inhibition increased the susceptibility of rat lungs to high-PIP injury, and tyrosine kinase inhibition attenuated the injury relative to the high-PIP control lungs.

  16. [A project to reduce the incidence of facial pressure ulcers caused by prolonged surgery with prone positioning].

    Science.gov (United States)

    Lee, Wen-Yi; Lin, Pao-Chen; Weng, Chia-Hsing; Lin, Yi-Lin; Tsai, Wen-Lin

    2012-06-01

    We observed in our institute a 13.6% incidence of prolonged surgery (>4 hours) induced facial pressure ulcers that required prone positioning. Causes identified included: (1) customized silicon face pillows used were not suited for every patient; (2) our institute lacked a standard operating procedure for prone positioning; (3) our institute lacked a postoperative evaluation and audit procedure for facial pressure ulcers. We designed a strategy to reduce post-prolonged surgery facial pressure ulcer incidence requiring prone positioning by 50% (i.e., from 13.6% to 6.8%). We implemented the following: (1) Created a new water pillow to relieve facial pressure; (2) Implemented continuing education pressure ulcer prevention and evaluation; (3) Established protocols on standard care for prone-position patients and proper facial pressure ulcer identification; (4) Established a face pressure ulcers accident reporting mechanism; and (5) Established an audit mechanism facial pressure ulcer cases. After implementing the resolution measures, 116 patients underwent prolonged surgery in a prone position (mean operating time: 298 mins). None suffered from facial pressure ulcers. The measures effectively reduced the incidence of facial pressure ulcers from 13.6% to 0.0%. The project used a water pillow to relieve facial pressure and educated staff to recognize and evaluate pressure ulcers. These measures were demonstrated effective in reducing the incidence of facial pressure ulcers caused by prolonged prone positioning.

  17. A novel animal model for hyperdynamic airway collapse.

    Science.gov (United States)

    Tsukada, Hisashi; O'Donnell, Carl R; Garland, Robert; Herth, Felix; Decamp, Malcolm; Ernst, Armin

    2010-12-01

    Tracheobronchomalacia (TBM) is increasingly recognized as a condition associated with significant pulmonary morbidity. However, treatment is invasive and complex, and because there is no appropriate animal model, novel diagnostic and treatment strategies are difficult to evaluate. We endeavored to develop a reliable airway model to simulate hyperdynamic airway collapse in humans. Seven 20-kg male sheep were enrolled in this study. Tracheomalacia was created by submucosal resection of > 50% of the circumference of 10 consecutive cervical tracheal cartilage rings through a midline cervical incision. A silicone stent was placed in the trachea to prevent airway collapse during recovery. Tracheal collapsibility was assessed at protocol-specific time points by bronchoscopy and multidetector CT imaging while temporarily removing the stent. Esophageal pressure and flow data were collected to assess flow limitation during spontaneous breathing. All animals tolerated the surgical procedure well and were stented without complications. One sheep died at 2 weeks because of respiratory failure related to stent migration. In all sheep, near-total forced inspiratory airway collapse was observed up to 3 months postprocedure. Esophageal manometry demonstrated flow limitation associated with large negative pleural pressure swings during rapid spontaneous inhalation. Hyperdynamic airway collapse can reliably be induced with this technique. It may serve as a model for evaluation of novel diagnostic and therapeutic strategies for TBM.

  18. Numerical Simulation for Mechanism of Airway Narrowing in Asthma

    Science.gov (United States)

    Bando, Kiyoshi; Yamashita, Daisuke; Ohba, Kenkichi

    A calculation model is proposed to examine the generation mechanism of the numerous lobes on the inner-wall of the airway in asthmatic patients and to clarify luminal occlusion of the airway inducing breathing difficulties. The basement membrane in the airway wall is modeled as a two-dimensional thin-walled shell having inertia force due to the mass, and the smooth muscle contraction effect is replaced by uniform transmural pressure applied to the basement membrane. A dynamic explicit finite element method is used as a numerical simulation method. To examine the validity of the present model, simulation of an asthma attack is performed. The number of lobes generated in the basement membrane increases when transmural pressure is applied in a shorter time period. When the remodeling of the basement membrane occurs characterized by thickening and hardening, it is demonstrated that the number of lobes decreases and the narrowing of the airway lumen becomes severe. Comparison of the results calculated by the present model with those measured for animal experiments of asthma will be possible.

  19. The position of the arm during blood pressure measurement in sitting position.

    NARCIS (Netherlands)

    Adiyaman, A.; Verhoeff, R.; Lenders, J.W.M.; Deinum, J.; Thien, Th.

    2006-01-01

    OBJECTIVE: Determining the influence of the position of the arm on blood pressure measurement in the sitting position. METHODS: Blood pressure of 128 individuals (the majority being treated hypertensive patients) visiting the outpatient clinic was measured simultaneously on both arms with arms in

  20. [Development of a continuous blood pressure monitoring and recording system].

    Science.gov (United States)

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  1. Airway structure and function in Eisenmenger's syndrome.

    Science.gov (United States)

    McKay, K O; Johnson, P R; Black, J L; Glanville, A R; Armour, C L

    1998-10-01

    The responsiveness of airways from patients with Eisenmenger's syndrome (n = 5) was compared with that in airways from organ donors (n = 10). Enhanced contractile responses to cholinergic stimulation were found in airways from patients with Eisenmenger's syndrome. The maximal responses to acetylcholine, carbachol, and parasympathetic nerve stimulation in airway tissue from these patients were 221%, 139%, and 152%, respectively, of the maximal responses obtained in donor tissue. Further, relaxation responses to isoproterenol and levocromakalim were absent (n = 2) or markedly impaired (n = 3) in airways from patients with Eisenmenger's syndrome. This attenuated relaxation response was nonspecific in that it was also absent after vasoactive intestinal peptide, sodium nitroprusside, papaverine, and electrical field application. These observations can most likely be explained by a decrease in intrinsic smooth muscle tone, as precontraction of airways revealed relaxation responses that were equivalent to those obtained in donor tissues. Morphometric analysis of tissues used for the functional studies revealed no differences in the airway dimensions (internal perimeter) or airway wall components (e.g., smooth muscle, cartilage) or total area to explain these observations. Although the mechanism for this observed decrease in intrinsic airway smooth muscle tone is not certain, it may be due to alteration in the substructure of the airway wall or, alternatively, may result from the continued release of depressant factors in the vicinity of the smooth muscle which permanently alters smooth muscle responsiveness.

  2. A passive quantitative measurement of airway resistance using depth data.

    Science.gov (United States)

    Ostadabbas, Sarah; Bulach, Christoph; Ku, David N; Anderson, Larry J; Ghovanloo, Maysam

    2014-01-01

    The Respiratory Syncytial Virus (RSV) is the most common cause of serious lower respiratory tract infections in infants and young children. RSV often causes increased airway resistance, clinically detected as wheezing by chest auscultation. In this disease, expiratory flows are significantly reduced due to the high resistance in patient's airway passages. A quantitative method for measuring resistance can have a great benefit to diagnosis and management of children with RSV infections as well as with other lung diseases. Airway resistance is defined as the lung pressure divided by the airflow. In this paper, we propose a method to quantify resistance through a simple, non-contact measurement of chest volume that can act as a surrogate measure of the lung pressure and volumetric airflow. We used depth data collected by a Microsoft Kinect camera for the measurement of the lung volume over time. In our experimentation, breathing through a number of plastic straws induced different airway resistances. For a standard spirometry test, our volume/flow estimation using Kinect showed strong correlation with the flow data collected by a commercially-available spirometer (five subjects, each performing 20 breathing trials, correlation coefficient = 0.88, with 95% confidence interval). As the number of straws decreased, emulating a higher airway obstruction, our algorithm was sufficient to distinguish between several levels of airway resistance.

  3. Influencing factors on CPAP adherence and anatomic characteristics of upper airway in OSA subjects.

    Science.gov (United States)

    Park, Pona; Kim, Jinil; Song, Yoon Jae; Lim, Jae Hyun; Cho, Sung Woo; Won, Tae-Bin; Han, Doo Hee; Kim, Dong-Young; Rhee, Chae Seo; Kim, Hyun Jik

    2017-12-01

    Although continuous positive airway pressure (CPAP) is the most effective treatment modality, poor adherence still remains a problem for obstructive sleep apnea (OSA) treatment and there is little evidence regarding how this might be improved. This study aims to analyze the anatomic and clinical factors of OSA subjects who failed to comply with CPAP therapy.The medical records of 47 OSA subjects who received CPAP therapy as a first-line treatment modality were retrospectively reviewed. The medical records were reviewed for demographic and polysomnographic data and anatomic findings of the nasal cavity and oropharynx.24 patients who adhered to CPAP therapy and 23 patients who were nonadherent were enrolled in the study. There were no statistically significant differences in sleep parameters between CPAP-adherent patients and CPAP nonadherent subjects. Mean body mass index of CPAP nonadherent group was significantly higher than CPAP adherent group. Higher grades of septal deviation and hypertrophic change of the inferior turbinate were observed more in the CPAP nonadherent group. In addition, CPAP nonadherent subjects showed considerably bigger tonsils and higher grade palatal position comparing with the CPAP adherent subjects. Subjective discomfort including inconvenience, mouth dryness, and chest discomfort were the main problems for OSA subjects who did not comply with CPAP therapy.Excessive upper airway blockage in the nasal cavity and oropharynx was predominant in CPAP nonadherent subjects, which might cause the reported subjective discomfort that reduces CPAP compliance. Therefore, resolution of these issues is needed to enhance CPAP compliance for control of OSA. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  4. Characteristics of the mach disk in the underexpanded jet in which the back pressure continuously changes with time

    Science.gov (United States)

    Irie, T.; Yasunobu, T.; Kashimura, H.; Setoguchi, T.

    2003-05-01

    When the high-pressure gas is exhausted to the vacuum chamber from the nozzle, the underexpanded supersonic jet contained with the Mach disk is generally formed. The eventual purpose of this study is to clarify the unsteady phenomenon of the underexpanded free jet when the back pressure continuously changes with time. The characteristic of the Mach disk has been clarified in consideration of the diameter and position of it by the numerical analysis in this paper. The sonic jet of the exit Mach number Me=1 is assumed and the axisymmetric conservational equation is solved by the TVD method in the numerical calculation. The diameter and position of the Mach disk differs with the results of a steady jet and the influence on the continuously changing of the back pressure is evidenced from the comparison with the case of steady supersonic jet.

  5. A mechanical design principle for tissue structure and function in the airway tree.

    Science.gov (United States)

    LaPrad, Adam S; Lutchen, Kenneth R; Suki, Béla

    2013-01-01

    With every breath, the dynamically changing mechanical pressures must work in unison with the cells and soft tissue structures of the lung to permit air to efficiently traverse the airway tree and undergo gas exchange in the alveoli. The influence of mechanics on cell and tissue function is becoming apparent, raising the question: how does the airway tree co-exist within its mechanical environment to maintain normal cell function throughout its branching structure of diminishing dimensions? We introduce a new mechanical design principle for the conducting airway tree in which mechanotransduction at the level of cells is driven to orchestrate airway wall structural changes that can best maintain a preferred mechanical microenvironment. To support this principle, we report in vitro radius-transmural pressure relations for a range of airway radii obtained from healthy bovine lungs and model the data using a strain energy function together with a thick-walled cylinder description. From this framework, we estimate circumferential stresses and incremental Young's moduli throughout the airway tree. Our results indicate that the conducting airways consistently operate within a preferred mechanical homeostatic state, termed mechanical homeostasis, that is characterized by a narrow range of circumferential stresses and Young's moduli. This mechanical homeostatic state is maintained for all airways throughout the tree via airway wall dimensional and mechanical relationships. As a consequence, cells within the airway walls throughout the airway tree experience similar oscillatory strains during breathing that are much smaller than previously thought. Finally, we discuss the potential implications of how the maintenance of mechanical homeostasis, while facilitating healthy tissue-level alterations necessary for maturation, may lead to airway wall structural changes capable of chronic asthma.

  6. A mechanical design principle for tissue structure and function in the airway tree.

    Directory of Open Access Journals (Sweden)

    Adam S LaPrad

    Full Text Available With every breath, the dynamically changing mechanical pressures must work in unison with the cells and soft tissue structures of the lung to permit air to efficiently traverse the airway tree and undergo gas exchange in the alveoli. The influence of mechanics on cell and tissue function is becoming apparent, raising the question: how does the airway tree co-exist within its mechanical environment to maintain normal cell function throughout its branching structure of diminishing dimensions? We introduce a new mechanical design principle for the conducting airway tree in which mechanotransduction at the level of cells is driven to orchestrate airway wall structural changes that can best maintain a preferred mechanical microenvironment. To support this principle, we report in vitro radius-transmural pressure relations for a range of airway radii obtained from healthy bovine lungs and model the data using a strain energy function together with a thick-walled cylinder description. From this framework, we estimate circumferential stresses and incremental Young's moduli throughout the airway tree. Our results indicate that the conducting airways consistently operate within a preferred mechanical homeostatic state, termed mechanical homeostasis, that is characterized by a narrow range of circumferential stresses and Young's moduli. This mechanical homeostatic state is maintained for all airways throughout the tree via airway wall dimensional and mechanical relationships. As a consequence, cells within the airway walls throughout the airway tree experience similar oscillatory strains during breathing that are much smaller than previously thought. Finally, we discuss the potential implications of how the maintenance of mechanical homeostasis, while facilitating healthy tissue-level alterations necessary for maturation, may lead to airway wall structural changes capable of chronic asthma.

  7. Evaluation of continuous and intermittent myocardial topical negative pressure

    DEFF Research Database (Denmark)

    Lindstedt, Sandra; Malmsjö, Malin; Gesslein, Bodil

    2008-01-01

    Topical negative pressure, commonly used in wound therapy, has been shown to increase blood flow and stimulate angiogenesis in subcutaneous tissue and skeletal muscle. In wound therapy, intermittent negative pressure is often preferred to continuous negative pressure as tissue exposed to intermit...

  8. Impediment in upper airway stabilizing forces assessed by phrenic nerve stimulation in sleep apnea patients

    Directory of Open Access Journals (Sweden)

    Vérin E

    2005-09-01

    Full Text Available Abstract Background The forces developed during inspiration play a key role in determining upper airway stability and the occurrence of nocturnal breathing disorders. Phrenic nerve stimulation applied during wakefulness is a unique tool to assess Upper airway dynamic properties and to measure the overall mechanical effects of the inspiratory process on UA stability. Objectives To compare the flow/pressure responses to inspiratory and expiratory twitches between sleep apnea subjects and normal subjects. Methods Inspiratory and expiratory twitches using magnetic nerve stimulation completed in eleven untreated sleep apnea subjects and ten normal subjects. Results In both groups, higher flow and pressure were reached during inspiratory twitches. The two groups showed no differences in expiratory twitch parameters. During inspiration, the pressure at which flow-limitation occurred was more negative in normals than in apneic subjects, but not reaching significance (p = 0.07. The relationship between pharyngeal pressure and flow adequately fitted with a polynomial regression model providing a measurement of upper airway critical pressure during twitch. This pressure significantly decreased in normals from expiratory to inspiratory twitches (-11.1 ± 1.6 and -15.7 ± 1.0 cm H2O respectively, 95% CI 1.6–7.6, p Conclusion Inspiratory-related upper airway dilating forces are impeded in sleep apnea patients.

  9. Airway smooth muscle cells : regulators of airway inflammation

    NARCIS (Netherlands)

    Zuyderduyn, Suzanne

    2007-01-01

    Airways from asthmatic subjects are more responsive to bronchoconstrictive stimuli than airways from healthy subjects. Airway smooth muscle (ASM) cells mediate contraction of the airways by responding to the bronchoconstrictive stimuli, which was thought to be the primary role of ASM cells. In this

  10. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    Science.gov (United States)

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  11. The frequency of nasal injury in newborns due to the use of continuous positive airway pressure with prongs La frecuencia de lesión nasal en neonatos causada por la presión positiva continua en las vías aéreas con prongs Frequência de lesão nasal em neonatos por uso de pressão positiva contínua nas vias aéreas com pronga

    Directory of Open Access Journals (Sweden)

    Renata Medeiros do Nascimento

    2009-08-01

    Full Text Available Continuous positive airway pressure (CPAP with prongs is the ventilatory support most used in newborns. Nasal injuries are complications that may arise due to the prolonged use of this device. This study aimed to determine the frequency of nasal injuries in newborns through the use of continuous positive airway pressure with prongs. A convenience sample composed of hospitalized newborns using prongs for more than two days was used. Data were collected through a structured form. Lesions were observed in all newborns, which were classified as: mild (79.6%, moderate (19.7% and severe (0.7%. The conclusion is that the use of prongs for more than two days represents a risk factor for the lesions to develop.La presión positiva continua en las vías aéreas con prongs es la asistencia ventiladora más utilizada en neonatología. Las lesiones nasales son complicaciones que pueden surgir debido al uso prolongado de ese dispositivo. Este estudio tuvo por objetivo determinar la frecuencia de las lesiones nasales en neonatos causadas debido al uso de presión positiva continua en las vías aéreas utilizando un prong. El muestreo fue por conveniencia, constituido de recién nacidos internados y usando prongs, y se excluyeron aquellos que utilizaban el dispositivo por un período inferior a dos días. Los datos fueron recolectas a través de un formulario estructurado. Se observaron lesiones en todos los recién nacidos, clasificadas en: ligera (79,6%, moderada (19,7% y severa (0,7%. Se concluyó que el tiempo de permanencia de las prongs, por más de dos días, es un factor de riesgo para la evolución de las etapas de las lesiones nasales.A pressão positiva contínua nas vias aéreas com pronga é a assistência ventilatória mais utilizada em neonatologia. Lesões nasais são complicações que podem surgir pelo uso prolongado desse dispositivo. Este estudo objetivou determinar a frequência de lesões nasais em neonatos por uso de pressão positiva

  12. A hierarchical scheme for geodesic anatomical labeling of airway trees

    DEFF Research Database (Denmark)

    Feragen, Aasa; Petersen, Jens; Owen, Megan

    2012-01-01

    We present a fast and robust supervised algorithm for label- ing anatomical airway trees, based on geodesic distances in a geometric tree-space. Possible branch label configurations for a given unlabeled air- way tree are evaluated based on the distances to a training set of labeled airway trees....... In tree-space, the airway tree topology and geometry change continuously, giving a natural way to automatically handle anatomical differences and noise. The algorithm is made efficient using a hierarchical approach, in which labels are assigned from the top down. We only use features of the airway...

  13. Canadian Thoracic Society 2011 Guideline Update: Diagnosis and Treatment of Sleep Disordered Breathing

    Directory of Open Access Journals (Sweden)

    John Fleetham

    2011-01-01

    Full Text Available The Canadian Thoracic Society (CTS published an executive summary of guidelines for the diagnosis and treatment of sleep disordered breathing in 2006/2007. These guidelines were developed during several meetings by a group of experts with evidence grading based on committee consensus. These guidelines were well received and the majority of the recommendations remain unchanged. The CTS embarked on a more rigorous process for the 2011 guideline update, and addressed eight areas that were believed to be controversial or in which new data emerged. The CTS Sleep Disordered Breathing Committee posed specific questions for each area. The recommendations regarding maximum assessment wait times, portable monitoring, treatment of asymptomatic adult obstructive sleep apnea patients, treatment with conventional continuous positive airway pressure compared with automatic continuous positive airway pressure, and treatment of central sleep apnea syndrome in heart failure patients replace the recommendations in the 2006/2007 guidelines. The recommendations on bariatric surgery, complex sleep apnea and optimum positive airway pressure technologies are new topics, which were not covered in the 2006/2007 guidelines.

  14. Effects of Lignocaine Administered Intravenously or Intratracheally on Airway and Hemodynamic Responses during Emergence and Extubation in Patients Undergoing Elective Craniotomies in Supine Position.

    Science.gov (United States)

    Shabnum, Tabasum; Ali, Zulfiqar; Naqash, Imtiaz Ahmad; Mir, Aabid Hussain; Azhar, Khan; Zahoor, Syed Amer; Mir, Abdul Waheed

    2017-01-01

    Sympathoadrenergic responses during emergence and extubation can lead to an increase in heart rate (HR) and blood pressure whereas increased airway responses may lead to coughing and laryngospasm. The aim of our study was to compare the effects of lignocaine administered intravenously (IV) or intratracheally on airway and hemodynamic responses during emergence and extubation in patients undergoing elective craniotomies. Sixty patients with physical status American Society of Anaesthesiologists Classes I and II aged 18-70 years, scheduled to undergo elective craniotomies were included. The patients were randomly divided into three groups of twenty patients; Group 1 receiving IV lignocaine and intratracheal placebo (IV group), Group 2 receiving intratracheal lignocaine and IV placebo (I/T group), and Group 3 receiving IV and intratracheal placebo (placebo group). The tolerance to the endotracheal tube was monitored, and number of episodes of cough was recorded during emergence and at the time of extubation. Hemodynamic parameters such as HR and blood pressure (systolic, diastolic, mean arterial pressure) were also recorded. There was a decrease of HR in both IV and intratracheal groups in comparison with placebo group ( P < 0.005). Rise in blood pressure (systolic blood pressure, diastolic blood pressure and mean arterial pressure) was comparable in both Groups 1 and 2 but was lower in comparison with placebo group ( P < 0.005). Cough suppression was comparable in all the three groups. Grade III cough (15%) was documented only in placebo group. Both IV and intratracheal lignocaine are effective in attenuation of hemodynamic response if given within 20 min from skull pin removal to extubation. There was comparable cough suppression through intratracheal route and IV routes than the placebo group.

  15. Pneumocephalus with BiPAP use after transsphenoidal surgery☆,☆☆,★

    Science.gov (United States)

    Kopelovich, Jonathan C.; de la Garza, Gabriel O.; Greenlee, Jeremy D.W.; Graham, Scott M.; Udeh, Chiedozie I.; O'Brien, Erin K.

    2013-01-01

    While the benefits of continuous positive airway pressure (CPAP) or bilevel positive airway pressure (BiPAP) for patients with obstructive sleep apnea are well described, reports in the literature of complications from its use are rare. A patient who received postoperative BiPAP after undergoing transsphenoidal craniopharyngioma resection developed severe pneumocephalus and unplanned intensive care unit admission. Although the pneumocephalus resolved with conservative management over two weeks, we propose caution in the use of CPAP postoperatively in patients undergoing procedures of the head and neck. PMID:22626688

  16. Automatic algorithm for monitoring systolic pressure variation and difference in pulse pressure.

    Science.gov (United States)

    Pestel, Gunther; Fukui, Kimiko; Hartwich, Volker; Schumacher, Peter M; Vogt, Andreas; Hiltebrand, Luzius B; Kurz, Andrea; Fujita, Yoshihisa; Inderbitzin, Daniel; Leibundgut, Daniel

    2009-06-01

    Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.

  17. Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure

    NARCIS (Netherlands)

    Imholz, B. P.; Settels, J. J.; van der Meiracker, A. H.; Wesseling, K. H.; Wieling, W.

    1990-01-01

    The aim of the study was to evaluate whether invasive blood pressure responses to orthostatic stress can be replaced by non-invasive continuous finger blood pressure responses. DESIGN - Intrabrachial and Finapres blood pressures were simultaneously measured during passive head up tilt and during

  18. [Effect of airway humidification on lung injury induced by mechanical ventilation].

    Science.gov (United States)

    Song, Junjie; Jiang, Min; Qi, Guiyan; Xie, Yuying; Wang, Huaiquan; Tian, Yonggang; Qu, Jingdong; Zhang, Xiaoming; Li, Haibo

    2014-12-01

    To explore the effect of airway humidification on lung injury as a result of mechanical ventilation with different tidal volume (VT). Twenty-four male Japanese white rabbits were randomly divided into four groups: low VT with airway humidification group, high VT with airway humidification group, low VT and high VT group without humidification, with 6 rabbits in each group. Mechanical ventilation was started after intubation and lasted for 6 hours. Low VT denoted 8 mL/kg, while high VT was 16 mL/kg, fraction of inspired oxygen (FiO₂) denoted 0.40, positive end-expiratory pressure (PEEP) was 0. Temperature at Y piece of circuit in airway humidification groups was monitored and controlled at 40 centigrade. Arterial blood gas analysis, including pH value, arterial partial pressure of oxygen (PaO₂), arterial partial pressure of carbon dioxide (PaCO₂), lung mechanics indexes, including peak airway pressure (P(peak)) and airway resistance (Raw), and lung compliance was measured at 0, 2, 4, 6 hours of mechanical ventilation. The levels of tumor necrosis factor-α (TNF-α) and interleukin-8 (IL-8) in plasma and bronchoalveolar lavage fluid (BALF) were determined by enzyme linked immunosorbent assay (ELISA). The animals were sacrificed at the end of mechanical ventilation. The wet to dry (W/D) ratio of lung tissues was calculated. Histopathologic changes in the lung tissueies were observed with microscope, and lung injury score was calculated. Scanning and transmission electron microscopies were used to examine the integrity of the airway cilia and the tracheal epithelium. Compared with low V(T) group, pH value in high V(T) group was significantly increased, PaCO₂was significantly lowered, and no difference in PaO₂was found. P(peak), Raw, and lung compliance were significantly increased during mechanical ventilation. There were no significant differences in blood gas analysis and lung mechanics indexes between low V(T) with airway humidification group and low V

  19. Guidelines and algorithms for managing the difficult airway.

    Science.gov (United States)

    Gómez-Ríos, M A; Gaitini, L; Matter, I; Somri, M

    2018-01-01

    The difficult airway constitutes a continuous challenge for anesthesiologists. Guidelines and algorithms are key to preserving patient safety, by recommending specific plans and strategies that address predicted or unexpected difficult airway. However, there are currently no "gold standard" algorithms or universally accepted standards. The aim of this article is to present a synthesis of the recommendations of the main guidelines and difficult airway algorithms. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Associations of Nasopharyngeal Metabolome and Microbiome with Severity among Infants with Bronchiolitis. A Multiomic Analysis.

    Science.gov (United States)

    Stewart, Christopher J; Mansbach, Jonathan M; Wong, Matthew C; Ajami, Nadim J; Petrosino, Joseph F; Camargo, Carlos A; Hasegawa, Kohei

    2017-10-01

    Bronchiolitis is the most common lower respiratory infection in infants; however, it remains unclear which infants with bronchiolitis will develop severe illness. In addition, although emerging evidence indicates associations of the upper-airway microbiome with bronchiolitis severity, little is known about the mechanisms linking airway microbes and host response to disease severity. To determine the relations among the nasopharyngeal airway metabolome profiles, microbiome profiles, and severity in infants with bronchiolitis. We conducted a multicenter prospective cohort study of infants (age metabolomic and metagenomic (16S ribosomal RNA gene and whole-genome shotgun sequencing) approaches to 144 nasopharyngeal airway samples collected within 24 hours of hospitalization, we determined metabolome and microbiome profiles and their association with higher severity, defined by the use of positive pressure ventilation (i.e., continuous positive airway pressure and/or intubation). Nasopharyngeal airway metabolome profiles significantly differed by bronchiolitis severity (P metabolomics to predict bronchiolitis severity and better understand microbe-host interaction.

  1. The All India Difficult Airway Association 2016 guidelines for tracheal intubation in the Intensive Care Unit

    Directory of Open Access Journals (Sweden)

    Sheila Nainan Myatra

    2016-01-01

    Full Text Available Tracheal intubation (TI is a routine procedure in the Intensive Care Unit (ICU and is often life-saving. In contrast to the controlled conditions in the operating room, critically ill patients with respiratory failure and shock are physiologically unstable. These factors, along with a suboptimal evaluation of the airway and limited oxygen reserves despite adequate pre-oxygenation, are responsible for a high incidence of life-threatening complications such as severe hypoxaemia and cardiovascular collapse during TI in the ICU. The All India Difficult Airway Association (AIDAA proposes a stepwise plan for safe management of the airway in critically ill patients. These guidelines have been developed based on available evidence; wherever robust evidence was lacking, recommendations were arrived at by consensus opinion of airway experts, incorporating the responses to a questionnaire sent to members of the AIDAA and the Indian Society of Anaesthesiologists. Non-invasive positive pressure ventilation during pre-oxygenation improves oxygen stores in patients with respiratory pathology. Nasal insufflation of oxygen at 15 L/min can increase the duration of apnoea before the occurrence of hypoxaemia. High-flow nasal cannula oxygenation at 60-70 L/min may also increase safety during TI in critically ill patients. Stable haemodynamics and gas exchange must be maintained during rapid sequence induction. It is necessary to implement an intubation protocol during routine airway management in the ICU. Adherence to a plan for difficult airway management incorporating the use of intubation aids and airway rescue devices and strategies is useful.

  2. ProSeal laryngeal mask airway as an alternative to standard endotracheal tube in securing upper airway in the patients undergoing beating-heart coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Kalpana Shah

    2017-01-01

    Full Text Available Background: ProSeal laryngeal mask airways (PLMAs are routinely used after failed tracheal intubation as airway rescue, facilitating tracheal intubation by acting as a conduit and to secure airway during emergencies. In long duration surgeries, use of endotracheal tube (ETT is associated with various hemodynamic complications, which are minimally affected during PLMA use. However, except for few studies, there are no significant data available that promote the use of laryngeal mask during cardiac surgery. This prospective study was conducted with the objective of demonstrating the advantages of PLMA over ETT in the patients undergoing beating-heart coronary artery bypass graft (CABG. Methodology: This prospective, interventional study was carried out in 200 patients who underwent beating-heart CABG. Patients were randomized in equal numbers to either ETT group or PLMA group, and various hemodynamic and respiratory parameters were observed at different time points. Results: Patients in PLMA group had mean systolic blood pressure 126.10 ± 5.31 mmHg compared to the patients of ETT group 143.75 ± 6.02 mmHg. Pulse rate in the PLMA group was less (74.52 ± 10.79 per min (P < 0.05 compared to ETT group (81.72 ± 9.8. Thus, hemodynamic changes were significantly lower (P < 0.05 in PLMA than in ETT group. Respiratory parameters such as oxygen saturation, pressure CO 2 (pCO 2 , peak airway pressure, and lung compliance were similar to ETT group at all evaluation times. The incidence of adverse events was also lower in PLMA group. Conclusion: In experience hand, PLMA offers advantages over the ETT in airway management in the patients undergoing beating-heart CABG.

  3. Loop Gain Predicts the Response to Upper Airway Surgery in Patients With Obstructive Sleep Apnea.

    Science.gov (United States)

    Joosten, Simon A; Leong, Paul; Landry, Shane A; Sands, Scott A; Terrill, Philip I; Mann, Dwayne; Turton, Anthony; Rangaswamy, Jhanavi; Andara, Christopher; Burgess, Glen; Mansfield, Darren; Hamilton, Garun S; Edwards, Bradley A

    2017-07-01

    Upper airway surgery is often recommended to treat patients with obstructive sleep apnea (OSA) who cannot tolerate continuous positive airways pressure. However, the response to surgery is variable, potentially because it does not improve the nonanatomical factors (ie, loop gain [LG] and arousal threshold) causing OSA. Measuring these traits clinically might predict responses to surgery. Our primary objective was to test the value of LG and arousal threshold to predict surgical success defined as 50% reduction in apnea-hypopnea index (AHI) and AHI <10 events/hour post surgery. We retrospectively analyzed data from patients who underwent upper airway surgery for OSA (n = 46). Clinical estimates of LG and arousal threshold were calculated from routine polysomnographic recordings presurgery and postsurgery (median of 124 [91-170] days follow-up). Surgery reduced both the AHI (39.1 ± 4.2 vs. 26.5 ± 3.6 events/hour; p < .005) and estimated arousal threshold (-14.8 [-22.9 to -10.2] vs. -9.4 [-14.5 to -6.0] cmH2O) but did not alter LG (0.45 ± 0.08 vs. 0.45 ± 0.12; p = .278). Responders to surgery had a lower baseline LG (0.38 ± 0.02 vs. 0.48 ± 0.01, p < .05) and were younger (31.0 [27.3-42.5] vs. 43.0 [33.0-55.3] years, p < .05) than nonresponders. Lower LG remained a significant predictor of surgical success after controlling for covariates (logistic regression p = .018; receiver operating characteristic area under curve = 0.80). Our study provides proof-of-principle that upper airway surgery most effectively resolves OSA in patients with lower LG. Predicting the failure of surgical treatment, consequent to less stable ventilatory control (elevated LG), can be achieved in the clinic and may facilitate avoidance of surgical failures. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  4. Noninvasive continuous blood pressure monitoring by the ClearSight system during robot-assisted laparoscopic radical prostatectomy.

    Science.gov (United States)

    Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya

    2018-01-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.

  5. Effect of parenchymal stiffness on canine airway size with lung inflation.

    Directory of Open Access Journals (Sweden)

    Robert H Brown

    2010-04-01

    Full Text Available Although airway patency is partially maintained by parenchymal tethering, this structural support is often ignored in many discussions of asthma. However, agonists that induce smooth muscle contraction also stiffen the parenchyma, so such parenchymal stiffening may serve as a defense mechanism to prevent airway narrowing or closure. To quantify this effect, specifically how changes in parenchymal stiffness alter airway size at different levels of lung inflation, in the present study, we devised a method to separate the effect of parenchymal stiffening from that of direct airway narrowing. Six anesthetized dogs were studied under four conditions: baseline, after whole lung aerosol histamine challenge, after local airway histamine challenge, and after complete relaxation of the airways. In each of these conditions, we used High resolution Computed Tomography to measure airway size and lung volume at five different airway pressures (0, 12, 25, 32, and 45 cm H(2O. Parenchymal stiffening had a protective effect on airway narrowing, a fact that may be important in the airway response to deep inspiration in asthma. When the parenchyma was stiffened by whole lung aerosol histamine challenge, at every lung volume above FRC, the airways were larger than when they were directly challenged with histamine to the same initial constriction. These results show for the first time that a stiff parenchyma per se minimizes the airway narrowing that occurs with histamine challenge at any lung volume. Thus in clinical asthma, it is not simply increased airway smooth muscle contraction, but perhaps a lack of homogeneous parenchymal stiffening that contributes to the symptomatic airway hyperresponsiveness.

  6. Continuous determination of optimal cerebral perfusion pressure in traumatic brain injury

    NARCIS (Netherlands)

    Aries, M.J.H.; Czosnyka, Marek; Budohoski, Karol P.; Steiner, Luzius A.; Lavinio, Andrea; Kolias, Angelos G.; Hutchinson, Peter J.; Brady, Ken M.; Menon, David K.; Pickard, John D.; Smielewski, Peter

    Objectives: We have sought to develop an automated methodology for the continuous updating of optimal cerebral perfusion pressure (CPPopt) for patients after severe traumatic head injury, using continuous monitoring of cerebrovascular pressure reactivity. We then validated the CPPopt algorithm by

  7. New frontiers in CT imaging of airway disease

    International Nuclear Information System (INIS)

    Grenier, Philippe A.; Beigelman-Aubry, Catherine; Fetita, Catalin; Preteux, Francoise; Brauner, Michel W.; Lenoir, Stephane

    2002-01-01

    Combining helical volumetric CT acquisition and thin-slice thickness during breath hold provides an accurate assessment of both focal and diffuse airway diseases. With multiple detector rows, compared with single-slice helical CT, multislice CT can cover a greater volume, during a simple breath hold, and with better longitudinal and in-plane spatial resolution and improved temporal resolution. The result in data set allows the generation of superior multiplanar and 3D images of the airways, including those obtained from techniques developed specifically for airway imaging, such as virtual bronchography and virtual bronchoscopy. Complementary CT evaluation at suspended or continuous full expiration is mandatory to detect air trapping that is a key finding for depicting an obstruction on the small airways. Indications for CT evaluation of the airways include: (a) detection of endobronchial lesions in patients with an unexplained hemoptysis; (b) evaluation of extent of tracheobronchial stenosis for planning treatment and follow-up; (c) detection of congenital airway anomalies revealed by hemoptysis or recurrent infection; (d) detection of postinfectious or postoperative airway fistula or dehiscence; and (e) diagnosis and assessment of extent of bronchiectasis and small airway disease. Improvement in image analysis technique and the use of spirometrically control of lung volume acquisition have made possible accurate and reproducible quantitative assessment of airway wall and lumen areas and lung density. This contributes to better insights in physiopathology of obstructive lung disease, particularly in chronic obstructive pulmonary disease and asthma. (orig.)

  8. Impact of continuous positive airway pressure on the pulmonary changes promoted by immersion in water

    OpenAIRE

    Rizzetti, Danize Aparecida; Quadros, Janayna Rodembuch Borba; Ribeiro, Bruna Esmerio; Callegaro, Letícia; Veppo, Aline Arebalo; Wiggers, Giulia Alessandra; Peçanha, Franck Maciel

    2017-01-01

    ABSTRACT Objective: To determine whether different levels of CPAP improve the lung volumes and capacities of healthy subjects immersed in water. Methods: This was a randomized clinical trial, conducted between April and June of 2016, involving healthy female volunteers who were using oral contraceptives. Three 20-min immersion protocols were applied: control (no CPAP); CPAP5 (CPAP at 5 cmH2O); and CPAP10 (CPAP at 10 cmH2O). We evaluated HR, SpO2, FVC, FEV1, the FEV1/FVC ratio, peak expirato...

  9. Early predictors of success of non-invasive positive pressure ventilation in hypercapnic respiratory failure.

    Science.gov (United States)

    Bhattacharyya, D; Prasad, Bnbm; Tampi, P S; Ramprasad, R

    2011-10-01

    Non-invasive positive pressure ventilation (NIPPV) has emerged as a significant advancement in the management of acute hypercapnic respiratory failure. Patients with hypercapnic respiratory failure requiring ventilation therapy (respiratory rate [RR] of > 30 breaths per minutes, PaCO2 > 55 mmHg and arterial pH success group and these parameters continued to improve even after four and 24 hours of NIPPV treatment. Out of 24 (24%) patients who failed to respond, 13 (54%) needed endotracheal intubation within one hour. The failure group had higher baseline HR than the success group. Improvement in HR, RR, pH, and PCO2 one hour after putting the patient on NIPPV predicts success of non-invasive positive pressure ventilation in hypercapnic respiratory failure.

  10. Airway distensibility in Chronic Obstructive Airway Disease

    DEFF Research Database (Denmark)

    Winkler Wille, Mathilde Marie; Pedersen, Jesper Holst; Dirksen, Asger

    2013-01-01

    Rationale – Chronic Obstructive Pulmonary Disease (COPD) is a combination of chronic bronchitis and emphysema, which both may lead to airway obstruction. Under normal circumstances, airway dimensions vary as a function of inspiration level. We aim to study the influence of COPD and emphysema......-20% (mild), 20%-30% (moderate) or >30% (severe). Spirometry was performed annually and participants were divided into severity groups according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD). Data were analysed in a mixed effects regression model with log(airway lumen diameter...... and emphysema, respectively. Conclusions – Airway distensibility decreases significantly with increasing severity of both GOLD status and emphysema, indicating that in COPD the dynamic change in airway calibre during respiration is compromised. Chronic bronchitis and emphysema appear to be interacting...

  11. Quality of Life in Youth With Obstructive Sleep Apnea Syndrome (OSAS) Treated With Continuous Positive Airway Pressure (CPAP) Therapy.

    Science.gov (United States)

    Lynch, Mary K; Elliott, Lindsey C; Avis, Kristin T; Schwebel, David C; Goodin, Burel R

    2017-05-30

    Improvement is sought for youth with obstructive sleep apnea syndrome (OSAS) who have poor quality of life (QoL), which resolves somewhat following treatment. One mitigating factor in improved QoL following treatment may be adherence to the CPAP protocol, which presents a barrier to most youth. This study explored relations between CPAP adherence and QoL in youth with OSAS. We recruited 42 youth-caregiver dyads in which youth between the ages of 8 and 16 years were diagnosed with OSAS and required CPAP use as part of their treatment plan. Following diagnosis of OSAS requiring treatment with CPAP therapy, caregivers completed baseline measures of OSAS-specific QoL. The OSAS-specific QoL domains assessed included sleep disturbance, physical symptoms, emotional distress, daytime function, and caregiver concern. Families received routine CPAP care for three months, after which caregivers again completed measures of OSAS-specific QoL. Adherence data were collected from smartcards within the CPAP machine after three months of treatment. Fifteen youth were adherent to CPAP therapy and 10 were not adherent. CPAP-adherent youth demonstrated significant changes in two domains of OSAS-specific QoL when compared to nonadherent youth: decreased sleep disturbance and decreased caregiver concern. CPAP adherence appears to be associated with positive changes in OSAS-specific QoL domains. It will be important for future research and clinical work to examine strategies for improving CPAP adherence in youth with OSAS.

  12. Role of IL-4 receptor α-positive CD4(+) T cells in chronic airway hyperresponsiveness.

    Science.gov (United States)

    Kirstein, Frank; Nieuwenhuizen, Natalie E; Jayakumar, Jaisubash; Horsnell, William G C; Brombacher, Frank

    2016-06-01

    TH2 cells and their cytokines are associated with allergic asthma in human subjects and with mouse models of allergic airway disease. IL-4 signaling through the IL-4 receptor α (IL-4Rα) chain on CD4(+) T cells leads to TH2 cell differentiation in vitro, implying that IL-4Rα-responsive CD4(+) T cells are critical for the induction of allergic asthma. However, mechanisms regulating acute and chronic allergen-specific TH2 responses in vivo remain incompletely understood. This study defines the requirements for IL-4Rα-responsive CD4(+) T cells and the IL-4Rα ligands IL-4 and IL-13 in the development of allergen-specific TH2 responses during the onset and chronic phase of experimental allergic airway disease. Development of acute and chronic ovalbumin (OVA)-induced allergic asthma was assessed weekly in CD4(+) T cell-specific IL-4Rα-deficient BALB/c mice (Lck(cre)IL-4Rα(-/lox)) and respective control mice in the presence or absence of IL-4 or IL-13. During acute allergic airway disease, IL-4 deficiency did not prevent the onset of TH2 immune responses and OVA-induced airway hyperresponsiveness or goblet cell hyperplasia, irrespective of the presence or absence of IL-4Rα-responsive CD4(+) T cells. In contrast, deficiency of IL-13 prevented allergic asthma, irrespective of the presence or absence of IL-4Rα-responsive CD4(+) T cells. Importantly, chronic allergic inflammation and airway hyperresponsiveness were dependent on IL-4Rα-responsive CD4(+) T cells. Deficiency in IL-4Rα-responsive CD4(+) T cells resulted in increased numbers of IL-17-producing T cells and, consequently, increased airway neutrophilia. IL-4-responsive T helper cells are dispensable for acute OVA-induced airway disease but crucial in maintaining chronic asthmatic pathology. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  13. Reduction of Eosinophils in Small Airways by Inhaled Steroids is Insufficient in Patients with Adult Asthma

    Directory of Open Access Journals (Sweden)

    Hiroshi Tanaka

    2006-01-01

    Conclusions: It was speculated that inhaled CFC-BDP and DP-FP might deposit mainly in large airways and fail to fully reach small airways, consequently allowing eosinophilic inflammation to continue in small airways.

  14. Noninvasive ventilation in patients with acute cardiogenic pulmonary edema

    Directory of Open Access Journals (Sweden)

    Andrea Bellone

    2013-07-01

    Full Text Available The term noninvasive ventilation (NIV encompasses two different modes of delivering positive airway pressure, namely continuous positive airway pressure (CPAP and bilevel positive airway pressure (bilevel-PAP. The two modes are different since CPAP does not actively assist inspiration whereas bilevel-PAP does. Bilevel-PAP is a type of noninvasive ventilation that helps keep the upper airways of the lungs open by providing a flow of air delivered through a face mask. The air is pressurized by a machine, which delivers it to the face mask through long, plastic hosing. With bilevel-PAP, the doctor prescribes specific alternating pressures: a higher pressure is used to breathe in (inspiratory positive airway pressure and a lower pressure is used to breath out (expiratory positive airway pressure. Noninvasive ventilation has been shown to reduce the rate of tracheal intubation. The main indications are exacerbation of chronic obstructive pulmonary disease and acute cardiogenic pulmonary edema (ACPE. This last is a common cause of respiratory failure with high incidence and high mortality rate. Clinical findings of ACPE are related to the increased extra-vascular water in the lungs and the resulting reduced lung compliance, increased airway resistance and elevated inspiratory muscle load which generates a depression in pleural pressure. These large pleural pressure swings are responsible for hemodynamic changes by increasing left ventricular afterload, myocardial transmural pressure, and venous return. These alterations can be detrimental to patients with left ventricular systolic dysfunction. Under these circumstances, NIV, either by CPAP or bilevel-PAP, improves vital signs, gas exchange, respiratory mechanics and hemodynamics by reducing left ventricular afterload and preload. In the first randomized study which compared the effectiveness of CPAP plus medical treatment vs medical treatment alone, the CPAP group showed a significant decrease in its

  15. Available techniques for objective assessment of upper airway narrowing in snoring and sleep apnea

    DEFF Research Database (Denmark)

    Faber, Christian; Grymer, Luisa

    2003-01-01

    positive airway pressure during sleep, fluoroscopy, CT scanning, MR scanning, manometry, and acoustic reflections. Data from different studies using various methods suggest that different patients have different patterns of narrowing or collapse of the pharynx. No reference standard exists...... option for different patients. This article lists criteria that must be used to assess the available techniques for diagnosis of obstruction level in snoring and OSAHS. The advantages and limitations of each diagnostic technique are summarized, with emphasis on the acoustic reflectometry technique....

  16. Integrated care pathways for airway diseases (AIRWAYS-ICPs)

    NARCIS (Netherlands)

    Bousquet, J.; Addis, A.; Adcock, I.; Agache, I.; Agusti, A.; Alonso, A.; Annesi-Maesano, I.; Anto, J. M.; Bachert, C.; Baena-Cagnani, C. E.; Bai, C.; Baigenzhin, A.; Barbara, C.; Barnes, P. J.; Bateman, E. D.; Beck, L.; Bedbrook, A.; Bel, E. H.; Benezet, O.; Bennoor, K. S.; Benson, M.; Bernabeu-Wittel, M.; Bewick, M.; Bindslev-Jensen, C.; Blain, H.; Blasi, F.; Bonini, M.; Bonini, S.; Boulet, L. P.; Bourdin, A.; Bourret, R.; Bousquet, P. J.; Brightling, C. E.; Briggs, A.; Brozek, J.; Buhl, R.; Bush, A.; Caimmi, D.; Calderon, M.; Calverley, P.; Camargos, P. A.; Camuzat, T.; Canonica, G. W.; Carlsen, K. H.; Casale, T. B.; Cazzola, M.; Cepeda Sarabia, A. M.; Cesario, A.; Chen, Y. Z.; Chkhartishvili, E.; Chavannes, N. H.; Chiron, R.; Chuchalin, A.; Chung, K. F.; Cox, L.; Crooks, G.; Crooks, M. G.; Cruz, A. A.; Custovic, A.; Dahl, R.; Dahlen, S. E.; de Blay, F.; Dedeu, T.; Deleanu, D.; Demoly, P.; Devillier, P.; Didier, A.; Dinh-Xuan, A. T.; Djukanovic, R.; Dokic, D.; Douagui, H.; Dubakiene, R.; Eglin, S.; Elliot, F.; Emuzyte, R.; Fabbri, L.; Fink Wagner, A.; Fletcher, M.; Fokkens, W. J.; Fonseca, J.; Franco, A.; Frith, P.; Furber, A.; Gaga, M.; Garcés, J.; Garcia-Aymerich, J.; Gamkrelidze, A.; Gonzales-Diaz, S.; Gouzi, F.; Guzmán, M. A.; Haahtela, T.; Harrison, D.; Hayot, M.; Heaney, L. G.; Heinrich, J.; Hellings, P. W.; Hooper, J.; Humbert, M.; Hyland, M.; Iaccarino, G.; Jakovenko, D.; Jardim, J. R.; Jeandel, C.; Jenkins, C.; Johnston, S. L.; Jonquet, O.; Joos, G.; Jung, K. S.; Kalayci, O.; Karunanithi, S.; Keil, T.; Khaltaev, N.; Kolek, V.; Kowalski, M. L.; Kull, I.; Kuna, P.; Kvedariene, V.; Le, L. T.; Lodrup Carlsen, K. C.; Louis, R.; MacNee, W.; Mair, A.; Majer, I.; Manning, P.; de Manuel Keenoy, E.; Masjedi, M. R.; Melen, E.; Melo-Gomes, E.; Menzies-Gow, A.; Mercier, G.; Mercier, J.; Michel, J. P.; Miculinic, N.; Mihaltan, F.; Milenkovic, B.; Molimard, M.; Momas, I.; Montilla-Santana, A.; Morais-Almeida, M.; Morgan, M.; N'Diaye, M.; Nafti, S.; Nekam, K.; Neou, A.; Nicod, L.; O'Hehir, R.; Ohta, K.; Paggiaro, P.; Palkonen, S.; Palmer, S.; Papadopoulos, N. G.; Papi, A.; Passalacqua, G.; Pavord, I.; Pigearias, B.; Plavec, D.; Postma, D. S.; Price, D.; Rabe, K. F.; Radier Pontal, F.; Redon, J.; Rennard, S.; Roberts, J.; Robine, J. M.; Roca, J.; Roche, N.; Rodenas, F.; Roggeri, A.; Rolland, C.; Rosado-Pinto, J.; Ryan, D.; Samolinski, B.; Sanchez-Borges, M.; Schünemann, H. J.; Sheikh, A.; Shields, M.; Siafakas, N.; Sibille, Y.; Similowski, T.; Small, I.; Sola-Morales, O.; Sooronbaev, T.; Stelmach, R.; Sterk, P. J.; Stiris, T.; Sud, P.; Tellier, V.; To, T.; Todo-Bom, A.; Triggiani, M.; Valenta, R.; Valero, A. L.; Valiulis, A.; Valovirta, E.; van Ganse, E.; Vandenplas, O.; Vasankari, T.; Vestbo, J.; Vezzani, G.; Viegi, G.; Visier, L.; Vogelmeier, C.; Vontetsianos, T.; Wagstaff, R.; Wahn, U.; Wallaert, B.; Whalley, B.; Wickman, M.; Williams, D. M.; Wilson, N.; Yawn, B. P.; Yiallouros, P. K.; Yorgancioglu, A.; Yusuf, O. M.; Zar, H. J.; Zhong, N.; Zidarn, M.; Zuberbier, T.

    2014-01-01

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy and will

  17. Integrated care pathways for airway diseases (AIRWAYS-ICPs)

    NARCIS (Netherlands)

    Bousquet, J.; Addis, A.; Adcock, I.; Agache, I.; Agusti, A.; Alonso, A.; Annesi-Maesano, I.; Anto, J. M.; Bachert, C.; Baena-Cagnani, C. E.; Bai, C.; Baigenzhin, A.; Barbara, C.; Barnes, P. J.; Bateman, E. D.; Beck, L.; Bedbrook, A.; Bel, E. H.; Benezet, O.; Bennoor, K. S.; Benson, M.; Bernabeu-Wittel, M.; Bewick, M.; Bindslev-Jensen, C.; Blain, H.; Blasi, F.; Bonini, M.; Bonini, S.; Boulet, L. P.; Bourdin, A.; Bourret, R.; Bousquet, P. J.; Brightling, C. E.; Briggs, A.; Brozek, J.; Buh, R.; Bush, A.; Caimmi, D.; Calderon, M.; Calverley, P.; Camargos, P. A.; Camuzat, T.; Canonica, G. W.; Carlsen, K. H.; Casale, T. B.; Cazzola, M.; Sarabia, A. M. Cepeda; Cesario, A.; Chen, Y. Z.; Chkhartishvili, E.; Chavannes, N. H.; Chiron, R.; Chuchalin, A.; Chung, K. F.; Cox, L.; Crooks, G.; Crooks, M. G.; Cruz, A. A.; Custovic, A.; Dahl, R.; Dahlen, S. E.; De Blay, F.; Dedeu, T.; Deleanu, D.; Demoly, P.; Devillier, P.; Didier, A.; Dinh-Xuan, A. T.; Djukanovic, R.; Dokic, D.; Douagui, H.; Dubakiene, R.; Eglin, S.; Elliot, F.; Emuzyte, R.; Fabbri, L.; Wagner, A. Fink; Fletcher, M.; Fokkens, W. J.; Fonseca, J.; Franco, A.; Frith, P.; Furber, A.; Gaga, M.; Garces, J.; Garcia-Aymerich, J.; Gamkrelidze, A.; Gonzales-Diaz, S.; Gouzi, F.; Guzman, M. A.; Haahtela, T.; Harrison, D.; Hayot, M.; Heaney, L. G.; Heinrich, J.; Hellings, P. W.; Hooper, J.; Humbert, M.; Hyland, M.; Iaccarino, G.; Jakovenko, D.; Jardim, J. R.; Jeandel, C.; Jenkins, C.; Johnston, S. L.; Jonquet, O.; Joos, G.; Jung, K. S.; Kalayci, O.; Karunanithi, S.; Keil, T.; Khaltaev, N.; Kolek, V.; Kowalski, M. L.; Kull, I.; Kuna, P.; Kvedariene, V.; Le, L. T.; Carlsen, K. C. Lodrup; Louis, R.; MacNee, W.; Mair, A.; Majer, I.; Manning, P.; Keenoy, E. de Manuel; Masjedi, M. R.; Meten, E.; Melo-Gomes, E.; Menzies-Gow, A.; Mercier, G.; Mercier, J.; Michel, J. P.; Miculinic, N.; Mihaltan, F.; Milenkovic, B.; Molimard, M.; Mamas, I.; Montilla-Santana, A.; Morais-Almeida, M.; Morgan, M.; N'Diaye, M.; Nafti, S.; Nekam, K.; Neou, A.; Nicod, L.; O'Hehir, R.; Ohta, K.; Paggiaro, P.; Palkonen, S.; Palmer, S.; Papadopoulos, N. G.; Papi, A.; Passalacqua, G.; Pavord, I.; Pigearias, B.; Plavec, D.; Postma, D. S.; Price, D.; Rabe, K. F.; Pontal, F. Radier; Redon, J.; Rennard, S.; Roberts, J.; Robine, J. M.; Roca, J.; Roche, N.; Rodenas, F.; Roggeri, A.; Rolland, C.; Rosado-Pinto, J.; Ryan, D.; Samolinski, B.; Sanchez-Borges, M.; Schunemann, H. J.; Sheikh, A.; Shields, M.; Siafakas, N.; Sibille, Y.; Similowski, T.; Small, I.; Sola-Morales, O.; Sooronbaev, T.; Stelmach, R.; Sterk, P. J.; Stiris, T.; Sud, P.; Tellier, V.; To, T.; Todo-Bom, A.; Triggiani, M.; Valenta, R.; Valero, A. L.; Valiulis, A.; Valovirta, E.; Van Ganse, E.; Vandenplas, O.; Vasankari, T.; Vestbo, J.; Vezzani, G.; Viegi, G.; Visier, L.; Vogelmeier, C.; Vontetsianos, T.; Wagstaff, R.; Wahn, U.; Wallaert, B.; Whalley, B.; Wickman, M.; Williams, D. M.; Wilson, N.; Yawn, B. P.; Yiallouros, P. K.; Yorgancioglu, A.; Yusuf, O. M.; Zar, H. J.; Zhong, N.; Zidarn, M.; Zuberbier, T.

    The objective of Integrated Care Pathways for Airway Diseases (AIRWAYS-ICPs) is to launch a collaboration to develop multi-sectoral care pathways for chronic respiratory diseases in European countries and regions. AIRWAYS-ICPs has strategic relevance to the European Union Health Strategy and will

  18. The contribution of airway smooth muscle to airway narrowing and airway hyperresponsiveness in disease.

    Science.gov (United States)

    Martin, J G; Duguet, A; Eidelman, D H

    2000-08-01

    Airway hyperresponsiveness (AHR), the exaggerated response to constrictor agonists in asthmatic subjects, is incompletely understood. Changes in either the quantity or properties of airway smooth muscle (ASM) are possible explanations for AHR. Morphometric analyses demonstrate structural changes in asthmatic airways, including subepithelial fibrosis, gland hyperplasia/hypertrophy, neovascularization and an increase in ASM mass. Mathematical modelling of airway narrowing suggests that, of all the changes in structure, the increase in ASM mass is the most probable cause of AHR. An increase in ASM mass in the large airways is more closely associated with a greater likelihood of dying from asthma than increases in ASM mass in other locations within the airway tree. ASM contraction is opposed by the elastic recoil of the lungs and airways, which appears to limit the degree of bronchoconstriction in vivo. The cyclical nature of tidal breathing applies stresses to the airway wall that enhance the bronchodilating influence of the lung tissues on the contracting ASM, in all probability by disrupting cross-bridges. However, the increase in ASM mass in asthma may overcome the limitation resulting from the impedances to ASM shortening imposed by the lung parenchyma and airway wall tissues. Additionally, ASM with the capacity to shorten rapidly may achieve shorter lengths and cause a greater degree of bronchoconstriction when stimulated to contract than slower ASM. Changes in ASM properties are induced by the process of sensitization and allergen-exposure such as enhancement of phospholipase C activity and inositol phosphate turnover, and increases in myosin light chain kinase activity. Whether changes in ASM mass or biochemical/biomechanical properties form the basis for asthma remains to be determined.

  19. A child with a difficult airway: what do I do next?

    Science.gov (United States)

    Engelhardt, Thomas; Weiss, Markus

    2012-06-01

    Difficulties in pediatric airway management are common and continue to result in significant morbidity and mortality. This review reports on current concepts in approaching a child with a difficult airway. Routine airway management in healthy children with normal airways is simple in experienced hands. Mask ventilation (oxygenation) is always possible and tracheal intubation normally simple. However, transient hypoxia is common in these children usually due to unexpected anatomical and functional airway problems or failure to ventilate during rapid sequence induction. Anatomical airway problems (upper airway collapse and adenoid hypertrophy) and functional airway problems (laryngospasm, bronchospasm, insufficient depth of anesthesia and muscle rigidity, gastric hyperinflation, and alveolar collapse) require urgent recognition and treatment algorithms due to insufficient oxygen reserves. Early muscle paralysis and epinephrine administration aids resolution of these functional airway obstructions. Children with an 'impaired' normal (foreign body, allergy, and inflammation) or an expected difficult (scars, tumors, and congenital) airway require careful planning and expertise. Training in the recognition and management of these different situations as well as a suitably equipped anesthesia workstation and trained personnel are essential. The healthy child with an unexpected airway problem requires clear strategies. The 'impaired' normal pediatric airway may be handled by anesthetists experienced with children, whereas the expected difficult pediatric airway requires dedicated pediatric anesthesia specialist care and should only be managed in specialized centers.

  20. Airway Management Dilemma in a Patient with Maxillofacial Injury ...

    African Journals Online (AJOL)

    He had tracheostomy and repair of the laceration under general anaesthesia. Anaesthesia was induced with intravenous ketamine with the patient in the left lateral position while traction on the tongue using a Magill's forceps ensured patency of the airway. A classical laryngeal mask airway was subsequently inserted to ...

  1. Anesthetic concerns in a huge congenital sublingual swelling obscuring airway access

    Directory of Open Access Journals (Sweden)

    Nilesh Kumar

    2015-01-01

    Full Text Available Presence of intraoral pathology poses a great challenge during management of pediatric airway. We report management of big intraoral cystic swelling physically occupying the entire oral cavity restricting access to airway. Preintubation aspiration of swelling was done to decrease its size and make room for airway manipulation, followed by laryngoscopy and intubation in lateral position. Airway patency is at risk in postoperative period also, in this case, though the swelling decreased in size postoperatively but presence of significant edema required placement of tongue stitch and modified nasopharyngeal airway. Case report highlights simple maneuvers to manage a difficult case.

  2. The role of high airway pressure and dynamic strain on ventilator-induced lung injury in a heterogeneous acute lung injury model.

    Science.gov (United States)

    Jain, Sumeet V; Kollisch-Singule, Michaela; Satalin, Joshua; Searles, Quinn; Dombert, Luke; Abdel-Razek, Osama; Yepuri, Natesh; Leonard, Antony; Gruessner, Angelika; Andrews, Penny; Fazal, Fabeha; Meng, Qinghe; Wang, Guirong; Gatto, Louis A; Habashi, Nader M; Nieman, Gary F

    2017-12-01

    Acute respiratory distress syndrome causes a heterogeneous lung injury with normal and acutely injured lung tissue in the same lung. Improperly adjusted mechanical ventilation can exacerbate ARDS causing a secondary ventilator-induced lung injury (VILI). We hypothesized that a peak airway pressure of 40 cmH 2 O (static strain) alone would not cause additional injury in either the normal or acutely injured lung tissue unless combined with high tidal volume (dynamic strain). Pigs were anesthetized, and heterogeneous acute lung injury (ALI) was created by Tween instillation via a bronchoscope to both diaphragmatic lung lobes. Tissue in all other lobes was normal. Airway pressure release ventilation was used to precisely regulate time and pressure at both inspiration and expiration. Animals were separated into two groups: (1) over-distension + high dynamic strain (OD + H DS , n = 6) and (2) over-distension + low dynamic strain (OD + L DS , n = 6). OD was caused by setting the inspiratory pressure at 40 cmH 2 O and dynamic strain was modified by changing the expiratory duration, which varied the tidal volume. Animals were ventilated for 6 h recording hemodynamics, lung function, and inflammatory mediators followed by an extensive necropsy. In normal tissue (N T ), OD + L DS caused minimal histologic damage and a significant reduction in BALF total protein (p < 0.05) and MMP-9 activity (p < 0.05), as compared with OD + H DS . In acutely injured tissue (ALI T ), OD + L DS resulted in reduced histologic injury and pulmonary edema (p < 0.05), as compared with OD + H DS . Both N T and ALI T are resistant to VILI caused by OD alone, but when combined with a H DS , significant tissue injury develops.

  3. Airway support using a pediatric intubation tube in adult patients with atrial fibrillation: A simple and unique method to prevent heart movement during catheter ablation under continuous deep sedation

    Directory of Open Access Journals (Sweden)

    Masateru Takigawa, MD

    2017-08-01

    Conclusion: This unique airway management technique using a pediatric intubation tube for CA procedures performed in adult patients with AF under continuous deep sedation was easy, safe, and effective.

  4. Innovative Application of a Microlaryngeal Surgery Tube for difficult Airway Management in a Case of Down's Syndrome.

    Science.gov (United States)

    Gulabani, Michell; Gupta, Akhilesh; Bannerjee, Neerja Gaur; Sood, Rajesh; Dass, Prashant

    2016-04-01

    An 11-year-old male child, known case of down's syndrome with congenital oesophageal stricture was posted for oesophageal dilatation. Preoperative airway assessment revealed a high arched palate, receding mandible and Mallampati Score of 2. During surgery, after loss of consciousness which was described as loss of eyelash reflex and adequate jaw relaxation, direct laryngoscopy and endotracheal intubation was attempted with a cuffed endotracheal tube number 5.0mm ID (internal diameter). The endotracheal tube could not be negotiated smoothly, so 5.0mm ID uncuffed endotracheal tube was used which passed through easily, but on auscultation revealed a significant leak. Later, intubation via a Micro Laryngeal Surgery (MLS) cuffed tube 4.0mm ID was attempted. The MLS tube advanced smoothly and there was no associated leak on positive pressure ventilation. Thus by innovative thinking and avant-garde reasoning, a definitive airway device could be positioned with no other suitable alternative at hand.

  5. A Patient-Specific Airway Branching Model for Mechanically Ventilated Patients

    Directory of Open Access Journals (Sweden)

    Nor Salwa Damanhuri

    2014-01-01

    Full Text Available Background. Respiratory mechanics models have the potential to guide mechanical ventilation. Airway branching models (ABMs were developed from classical fluid mechanics models but do not provide accurate models of in vivo behaviour. Hence, the ABM was improved to include patient-specific parameters and better model observed behaviour (ABMps. Methods. The airway pressure drop of the ABMps was compared with the well-accepted dynostatic algorithm (DSA in patients diagnosed with acute respiratory distress syndrome (ARDS. A scaling factor (α was used to equate the area under the pressure curve (AUC from the ABMps to the AUC of the DSA and was linked to patient state. Results. The ABMps recorded a median α value of 0.58 (IQR: 0.54–0.63; range: 0.45–0.66 for these ARDS patients. Significantly lower α values were found for individuals with chronic obstructive pulmonary disease (P<0.001. Conclusion. The ABMps model allows the estimation of airway pressure drop at each bronchial generation with patient-specific physiological measurements and can be generated from data measured at the bedside. The distribution of patient-specific α values indicates that the overall ABM can be readily improved to better match observed data and capture patient condition.

  6. Analysis of discrete and continuous distributions of ventilatory time constants from dynamic computed tomography

    International Nuclear Information System (INIS)

    Doebrich, Marcus; Markstaller, Klaus; Karmrodt, Jens; Kauczor, Hans-Ulrich; Eberle, Balthasar; Weiler, Norbert; Thelen, Manfred; Schreiber, Wolfgang G

    2005-01-01

    In this study, an algorithm was developed to measure the distribution of pulmonary time constants (TCs) from dynamic computed tomography (CT) data sets during a sudden airway pressure step up. Simulations with synthetic data were performed to test the methodology as well as the influence of experimental noise. Furthermore the algorithm was applied to in vivo data. In five pigs sudden changes in airway pressure were imposed during dynamic CT acquisition in healthy lungs and in a saline lavage ARDS model. The fractional gas content in the imaged slice (FGC) was calculated by density measurements for each CT image. Temporal variations of the FGC were analysed assuming a model with a continuous distribution of exponentially decaying time constants. The simulations proved the feasibility of the method. The influence of experimental noise could be well evaluated. Analysis of the in vivo data showed that in healthy lungs ventilation processes can be more likely characterized by discrete TCs whereas in ARDS lungs continuous distributions of TCs are observed. The temporal behaviour of lung inflation and deflation can be characterized objectively using the described new methodology. This study indicates that continuous distributions of TCs reflect lung ventilation mechanics more accurately compared to discrete TCs

  7. Obstetric airway management | Bishop | Southern African Journal of ...

    African Journals Online (AJOL)

    Obstetric airway management continues to provide a challenge to anaesthetists. The incidence of difficult and failed intubations has either remained static, or improved slightly, in specific settings in recent years. Established dogma is being challenged and practice continues to evolve and adapt to new evidence.

  8. Multidisciplinary Difficult Airway Course: An Essential Educational Component of a Hospital-Wide Difficult Airway Response Program.

    Science.gov (United States)

    Leeper, W Robert; Haut, Elliott R; Pandian, Vinciya; Nakka, Sajan; Dodd-O, Jeffrey; Bhatti, Nasir; Hunt, Elizabeth A; Saheed, Mustapha; Dalesio, Nicholas; Schiavi, Adam; Miller, Christina; Kirsch, Thomas D; Berkow, Lauren

    2018-04-05

    A hospital-wide difficult airway response team was developed in 2008 at The Johns Hopkins Hospital with three central pillars: operations, safety monitoring, and education. The objective of this study was to assess the outcomes of the educational pillar of the difficult airway response team program, known as the multidisciplinary difficult airway course (MDAC). The comprehensive, full-day MDAC involves trainees and staff from all provider groups who participate in airway management. The MDAC occurs within the Johns Hopkins Medicine Simulation Center approximately four times per year and uses a combination of didactic lectures, hands-on sessions, and high-fidelity simulation training. Participation in MDAC is the main intervention being investigated in this study. Data were collected prospectively using course evaluation survey with quantitative and qualitative components, and prepost course knowledge assessment multiple choice questions (MCQ). Outcomes include course evaluation scores and themes derived from qualitative assessments, and prepost course knowledge assessment MCQ scores. Tertiary care academic hospital center PARTICIPANTS: Students, residents, fellows, and practicing physicians from the departments of Surgery, Otolaryngology Head and Neck Surgery, Anesthesiology/Critical Care Medicine, and Emergency Medicine; advanced practice providers (nurse practitioners and physician assistants), nurse anesthetists, nurses, and respiratory therapists. Totally, 23 MDACs have been conducted, including 499 participants. Course evaluations were uniformly positive with mean score of 86.9 of 95 points. Qualitative responses suggest major value from high-fidelity simulation, the hands-on skill stations, and teamwork practice. MCQ scores demonstrated significant improvement: median (interquartile range) pre: 69% (60%-81%) vs post: 81% (72%-89%), p < 0.001. Implementation of a MDAC successfully disseminated principles and protocols to all airway providers. Demonstrable

  9. Trefoil factor-2 reverses airway remodeling changes in allergic airways disease.

    Science.gov (United States)

    Royce, Simon G; Lim, Clarice; Muljadi, Ruth C; Samuel, Chrishan S; Ververis, Katherine; Karagiannis, Tom C; Giraud, Andrew S; Tang, Mimi L K

    2013-01-01

    Trefoil factor 2 (TFF2) is a small peptide with an important role in mucosal repair. TFF2 is up-regulated in asthma, suggesting a role in asthma pathogenesis. Given its known biological role in promoting epithelial repair, TFF2 might be expected to exert a protective function in limiting the progression of airway remodeling in asthma. The contribution of TFF2 to airway remodeling in asthma was investigated by examining the expression of TFF2 in the airway and lung, and evaluating the effects of recombinant TFF2 treatment on established airway remodeling in a murine model of chronic allergic airways disease (AAD). BALB/c mice were sensitized and challenged with ovalbumin (OVA) or saline for 9 weeks, whereas mice with established OVA-induced AAD were treated with TFF2 or vehicle control (intranasally for 14 d). Effects on airway remodeling, airway inflammation, and airway hyperresponsiveness were then assessed, whereas TFF2 expression was determined by immunohistochemistry. TFF2 expression was significantly increased in the airways of mice with AAD, compared with expression levels in control mice. TFF2 treatment resulted in reduced epithelial thickening, subepithelial collagen deposition, goblet-cell metaplasia, bronchial epithelium apoptosis, and airway hyperresponsiveness (all P < 0.05, versus vehicle control), but TFF2 treatment did not influence airway inflammation. The increased expression of endogenous TFF2 in response to chronic allergic inflammation is insufficient to prevent the progression of airway inflammation and remodeling in a murine model of chronic AAD. However, exogenous TFF2 treatment is effective in reversing aspects of established airway remodeling. TFF2 has potential as a novel treatment for airway remodeling in asthma.

  10. Mechanical breath profile of airway pressure release ventilation: the effect on alveolar recruitment and microstrain in acute lung injury.

    Science.gov (United States)

    Kollisch-Singule, Michaela; Emr, Bryanna; Smith, Bradford; Roy, Shreyas; Jain, Sumeet; Satalin, Joshua; Snyder, Kathy; Andrews, Penny; Habashi, Nader; Bates, Jason; Marx, William; Nieman, Gary; Gatto, Louis A

    2014-11-01

    Improper mechanical ventilation settings can exacerbate acute lung injury by causing a secondary ventilator-induced lung injury. It is therefore important to establish the mechanism by which the ventilator induces lung injury to develop protective ventilation strategies. It has been postulated that the mechanism of ventilator-induced lung injury is the result of heterogeneous, elevated strain on the pulmonary parenchyma. Acute lung injury has been associated with increases in whole-lung macrostrain, which is correlated with increased pathology. However, the effect of mechanical ventilation on alveolar microstrain remains unknown. To examine whether the mechanical breath profile of airway pressure release ventilation (APRV), consisting of a prolonged pressure-time profile and brief expiratory release phase, reduces microstrain. In a randomized, nonblinded laboratory animal study, rats were randomized into a controlled mandatory ventilation group (n = 3) and an APRV group (n = 3). Lung injury was induced by polysorbate lavage. A thoracotomy was performed and an in vivo microscope was placed on the lungs to measure alveolar mechanics. In the controlled mandatory ventilation group, multiple levels of positive end-expiratory pressure (PEEP; 5, 10, 16, 20, and 24 cm H2O) were tested. In the APRV group, decreasing durations of expiratory release (time at low pressure [T(low)]) were tested. The T(low) was set to achieve ratios of termination of peak expiratory flow rate (T-PEFR) to peak expiratory flow rate (PEFR) of 10%, 25%, 50%, and 75% (the smaller this ratio is [ie, 10%], the more time the lung is exposed to low pressure during the release phase, which decreases end-expiratory lung volume and potentiates derecruitment). Alveolar perimeters were measured at peak inspiration and end expiration using digital image analysis, and strain was calculated by normalizing the change in alveolar perimeter length to the original length. Macrostrain was measured by volume

  11. Hemodynamic Effects of Noninvasive Ventilation in Patients with Venocapillary Pulmonary Hypertension

    Directory of Open Access Journals (Sweden)

    André Moreira Bento

    2014-11-01

    Full Text Available Background: The hemodynamic effects of noninvasive ventilation with positive pressure in patients with pulmonary hypertension without left ventricular dysfunction are not clearly established. Objectives: Analyze the impact of increasing airway pressure with continuous positive airway pressure on hemodynamic parameters and, in particular, on cardiac output in patients with variable degrees of pulmonary hypertension. Methods: The study included 38 patients with pulmonary hypertension caused by mitral stenosis without left ventricular dysfunction or other significant valvulopathy. The hemodynamic state of these patients was analyzed in three conditions: baseline, after continuous positive pressure of 7 cmH2O and, finally, after pressure of 14 cmH2O. Results: The population was composed of predominantly young and female individuals with significant elevation in pulmonary arterial pressure (mean systolic pressure of 57 mmHg. Of all variables analyzed, only the right atrial pressure changed across the analyzed moments (from the baseline condition to the pressure of 14 cmH2O there was a change from 8 ± 4 mmHg to 11 ± 3 mmHg, respectively, p = 0.031. Even though there was no variation in mean cardiac output, increased values in pulmonary artery pressure were associated with increased cardiac output. There was no harmful effect or other clinical instability associated with use application of airway pressure. Conclusion: In patients with venocapillary pulmonary hypertension without left ventricular dysfunction, cardiac output response was directly associated with the degree of pulmonary hypertension. The application of noninvasive ventilation did not cause complications directly related to the ventilation systems.

  12. Dense pulmonary opacification in neonates treated with extracorporeal membrane oxygenation

    Energy Technology Data Exchange (ETDEWEB)

    Schlesinger, A.E.; Cornish, J.D.; Null, D.M.

    1986-09-01

    Chest radiographic findings in three neonates with respiratory failure secondary to meconium aspiration treated with extracorporeal membrane oxygenation (ECMO) are described. The degree of pulmonary opacification on the chest radiographs failed to correlate with the patients' clinical status as measured by the arterial oxygen levels but correlated well with the peak airway pressure (PAP) and continuous positive airway pressure (CPAP) settings on the mechanical ventilator. Because a variable portion of the arterial blood oxygenation is performed by the extracorporeal membrane oxygenator and unusually large fluctuations in airway pressure settings can occur in these patients while on ECMO, it is important to realize that the chest radiography may not be an accurate predictor of the patients' clinical status.

  13. Dense pulmonary opacification in neonates treated with extracorporeal membrane oxygenation

    International Nuclear Information System (INIS)

    Schlesinger, A.E.; Cornish, J.D.; Null, D.M.

    1986-01-01

    Chest radiographic findings in three neonates with respiratory failure secondary to meconium aspiration treated with extracorporeal membrane oxygenation (ECMO) are described. The degree of pulmonary opacification on the chest radiographs failed to correlate with the patients' clinical status as measured by the arterial oxygen levels but correlated well with the peak airway pressure (PAP) and continuous positive airway pressure (CPAP) settings on the mechanical ventilator. Because a variable portion of the arterial blood oxygenation is performed by the extracorporeal membrane oxygenator and unusually large fluctuations in airway pressure settings can occur in these patients while on ECMO, it is important to realize that the chest radiography may not be an accurate predictor of the patients' clinical status. (orig.)

  14. Interventions designed using quality improvement methods reduce the incidence of serious airway events and airway cardiac arrests during pediatric anesthesia.

    Science.gov (United States)

    Spaeth, James P; Kreeger, Renee; Varughese, Anna M; Wittkugel, Eric

    2016-02-01

    Although serious complications during pediatric anesthesia are less common than they were 20 years ago, serious airway events continue to occur. Based on Quality Improvement (QI) data from our institution, a QI project was designed to reduce the incidence of serious airway events and airway cardiac arrests. A quality improvement team consisting of members of the Department of Anesthesia was formed and QI data from previous years were analyzed. The QI team developed a Smart Aim, Key Driver Diagram, and specific Interventions that focused on the accessibility of emergency drugs, the use of nondepolarizing muscle relaxants for endotracheal intubation in children 2 years and younger, and the presence of anesthesia providers until emergence from anesthesia in high-risk patients. The percentage of cases where muscle relaxants were utilized in children 2 years and younger for endotracheal intubation and where atropine and succinylcholine were readily available increased at both our base and outpatient facilities. Over the 2.5-year study period, the incidence of serious airway events and airway cardiac arrests was reduced by 44% and 59%, respectively compared to the previous 2-year period. We utilized QI methodology to design and implement a project which led to greater standardization of clinical practice within a large pediatric anesthesia group. Based on an understanding of system issues impacting our clinical practice, we designed and tested interventions that led to a significant reduction in the incidence of serious airway events and airway cardiac arrests. © 2015 John Wiley & Sons Ltd.

  15. In vitro biomechanical comparison of three different types of single- and double-row arthroscopic rotator cuff repairs: analysis of continuous bone-tendon contact pressure and surface during different simulated joint positions.

    Science.gov (United States)

    Grimberg, Jean; Diop, Amadou; Kalra, Kunal; Charousset, Christophe; Duranthon, Louis-Denis; Maurel, Nathalie

    2010-03-01

    We assessed bone-tendon contact surface and pressure with a continuous and reversible measurement system comparing 3 different double- and single-row techniques of cuff repair with simulation of different joint positions. We reproduced a medium supraspinatus tear in 24 human cadaveric shoulders. For the 12 right shoulders, single-row suture (SRS) and then double-row bridge suture (DRBS) were used. For the 12 left shoulders, DRBS and then double-row cross suture (DRCS) were used. Measurements were performed before, during, and after knot tying and then with different joint positions. There was a significant increase in contact surface with the DRBS technique compared with the SRS technique and with the DRCS technique compared with the SRS or DRBS technique. There was a significant increase in contact pressure with the DRBS technique and DRCS technique compared with the SRS technique but no difference between the DRBS technique and DRCS technique. The DRCS technique seems to be superior to the DRBS and SRS techniques in terms of bone-tendon contact surface and pressure. Copyright 2010 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  16. Comparison of pulsed versus continuous oxygen delivery using realistic adult nasal airway replicas

    Directory of Open Access Journals (Sweden)

    Chen JZ

    2017-08-01

    Full Text Available John Z Chen,1 Ira M Katz,2 Marine Pichelin,2 Kaixian Zhu,3 Georges Caillibotte,2 Michelle L Noga,4 Warren H Finlay,1 Andrew R Martin1 1Department of Mechanical Engineering, University of Alberta, Edmonton, AB, Canada; 2Medical R&D, Air Liquide Santé International, Centre de Recherche Paris-Saclay, Les Loges-en-Josas, 3Centre Explor!, Air Liquide Healthcare, Gentilly, France; 4Radiology and Diagnostic Imaging, University of Alberta, Edmonton, AB, Canada Background: Portable oxygen concentrators (POCs typically include pulse flow (PF modes to conserve oxygen. The primary aims of this study were to develop a predictive in vitro model for inhaled oxygen delivery using a set of realistic airway replicas, and to compare PF for a commercial POC with steady flow (SF from a compressed oxygen cylinder. Methods: Experiments were carried out using a stationary compressed oxygen cylinder, a POC, and 15 adult nasal airway replicas based on airway geometries derived from medical images. Oxygen delivery via nasal cannula was tested at PF settings of 2.0 and 6.0, and SF rates of 2.0 and 6.0 L/min. A test lung simulated three breathing patterns representative of a chronic obstructive pulmonary disease patient at rest, during exercise, and while asleep. Volume-averaged fraction of inhaled oxygen (FiO2 was calculated by analyzing oxygen concentrations sampled at the exit of each replica and inhalation flow rates over time. POC pulse volumes were also measured using a commercial O2 conserver test system to attempt to predict FiO2 for PF. Results: Relative volume-averaged FiO2 using PF ranged from 68% to 94% of SF values, increasing with breathing frequency and tidal volume. Three of 15 replicas failed to trigger the POC when used with the sleep breathing pattern at the 2.0 setting, and four of 15 replicas failed to trigger at the 6.0 setting. FiO2 values estimated from POC pulse characteristics followed similar trends but were lower than those derived from

  17. Upper Airway Stimulation for Obstructive Sleep Apnea: Results from the ADHERE Registry.

    Science.gov (United States)

    Boon, Maurits; Huntley, Colin; Steffen, Armin; Maurer, Joachim T; Sommer, J Ulrich; Schwab, Richard; Thaler, Erica; Soose, Ryan; Chou, Courtney; Strollo, Patrick; Kezirian, Eric J; Chia, Stanley; Withrow, Kirk; Weidenbecher, Mark; Strohl, Kingman; Doghramji, Karl; Hofauer, Benedikt; Heiser, Clemens

    2018-03-01

    Objective Upper airway stimulation (UAS) is an alternative treatment option for patients unable to tolerate continuous positive airway pressure (CPAP) for the treatment of obstructive sleep apnea (OSA). Studies support the safety and efficacy of this therapy. The aim of this registry is to collect retrospective and prospective objective and subjective outcome measures across multiple institutions in the United States and Germany. To date, it represents the largest cohort of patients studied with this therapy. Study Design Retrospective and prospective registry study. Setting Ten tertiary care hospitals in the United States and Germany. Subjects and Methods Patients were included who had moderate to severe OSA, were intolerant to CPAP, and were undergoing UAS implantation. Baseline demographic and sleep study data were collected. Objective and subjective treatment outcomes, adverse events, and patient and physician satisfaction were reviewed. Results The registry enrolled 301 patients between October 2016 and September 2017. Mean ± SD AHI decreased from 35.6 ± 15.3 to 10.2 ± 12.9 events per hour ( P < .0001), and Epworth Sleepiness Scale scores decreased from 11.9 ± 5.5 to 7.5 ± 4.7 ( P < .0001) from baseline to the posttitration visit. Patients utilized therapy for 6.5 hours per night. There were low rates of procedure- and device-related complications. Clinical global impression scores demonstrated that the majority of physicians (94%) saw improvement in their patients' symptoms with therapy. The majority of patients (90%) were more satisfied with UAS than CPAP. Conclusions Across a multi-institutional registry, UAS therapy demonstrates significant improvement in subjective and objective OSA outcomes, good therapy adherence, and high patient satisfaction.

  18. Positive Behavior Support: Sustainability and Continuous Regeneration

    Science.gov (United States)

    McIntosh, Kent; Turri, Mary G.

    2014-01-01

    Because of its widespread adoption and implementation (in over 13,000 schools in the US; Center on Positive Behavioral Interventions and Supports, 2010), there has been increasing attention to how School-wide Positive Behavior Support (SWPBS) systems can be sustained. Sustained implementation can be defined as "continued use of an…

  19. Risk factors for small pharyngeal airway dimensions in preorthodontic children

    DEFF Research Database (Denmark)

    Anandarajah, Seerone; Dudhia, Raahib; Sandham, Andrew

    2017-01-01

    Objective: To analyze which parameters, gathered from standard orthodontic diagnostic material, were most relevant for identifying small pharyngeal airway dimensions in preorthodontic children. Materials and Methods: The sample was composed of 105 cone beam computed tomography scans of healthy......, skeletal maturity and gender significant associations were found between pharyngeal airway dimensions and craniofacial morphology. Airway volume was positively associated with maxillary and mandibular width (P ... and sagittal jaw relationship were the most relevant factors for minimal cross-sectional area (r2 = 0.16). Conclusion: Pharyngeal airway dimensions were significantly associated with age, skeletal maturity, and craniofacial morphology in all three planes. Children with a reduced mandibular width and increased...

  20. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  1. Mechanisms of mechanical strain memory in airway smooth muscle.

    Science.gov (United States)

    Kim, Hak Rim; Hai, Chi-Ming

    2005-10-01

    We evaluated the hypothesis that mechanical deformation of airway smooth muscle induces structural remodeling of airway smooth muscle cells, thereby modulating mechanical performance in subsequent contractions. This hypothesis implied that past experience of mechanical deformation was retained (or "memorized") as structural changes in airway smooth muscle cells, which modulated the cell's subsequent contractile responses. We termed this phenomenon mechanical strain memory. Preshortening has been found to induce attenuation of both force and isotonic shortening velocity in cholinergic receptor-activated airway smooth muscle. Rapid stretching of cholinergic receptor-activated airway smooth muscle from an initial length to a final length resulted in post-stretch force and myosin light chain phosphorylation that correlated significantly with initial length. Thus post-stretch muscle strips appeared to retain memory of the initial length prior to rapid stretch (mechanical strain memory). Cytoskeletal recruitment of actin- and integrin-binding proteins and Erk 1/2 MAPK appeared to be important mechanisms of mechanical strain memory. Sinusoidal length oscillation led to force attenuation during oscillation and in subsequent contractions in intact airway smooth muscle, and p38 MAPK appeared to be an important mechanism. In contrast, application of local mechanical strain to cultured airway smooth muscle cells induced local actin polymerization and cytoskeletal stiffening. It is conceivable that deep inspiration-induced bronchoprotection may be a manifestation of mechanical strain memory such that mechanical deformation from past breathing cycles modulated the mechanical performance of airway smooth muscle in subsequent cycles in a continuous and dynamic manner.

  2. Feasibility of ambulatory, continuous 24-hour finger arterial pressure recording

    NARCIS (Netherlands)

    Imholz, B. P.; Langewouters, G. J.; van Montfrans, G. A.; Parati, G.; van Goudoever, J.; Wesseling, K. H.; Wieling, W.; Mancia, G.

    1993-01-01

    We tested Portapres, an innovative portable, battery-operated device for the continuous, noninvasive, 24-hour ambulatory measurement of blood pressure in the finger. Portapres is based on Finapres, a stationary device for the measurement of finger arterial pressure. Systems were added to record

  3. Fluid structure interaction simulations of the upper airway in obstructive sleep apnea patients before and after maxillomandibular advancement surgery.

    Science.gov (United States)

    Chang, Kwang K; Kim, Ki Beom; McQuilling, Mark W; Movahed, Reza

    2018-06-01

    The purpose of this study was to analyze pharyngeal airflow using both computational fluid dynamics (CFD) and fluid structure interactions (FSI) in obstructive sleep apnea patients before and after maxillomandibular advancement (MMA) surgery. The airflow characteristics before and after surgery were compared with both CFD and FSI. In addition, the presurgery and postsurgery deformations of the airway were evaluated using FSI. Digitized pharyngeal airway models of 2 obstructive sleep apnea patients were generated from cone-beam computed tomography scans before and after MMA surgery. CFD and FSI were used to evaluate the pharyngeal airflow at a maximum inspiration rate of 166 ml per second. Standard steady-state numeric formulations were used for airflow simulations. Airway volume increased, pressure drop decreased, maximum airflow velocity decreased, and airway resistance dropped for both patients after the MMA surgery. These findings occurred in both the CFD and FSI simulations. The FSI simulations showed an area of marked airway deformation in both patients before surgery, but this deformation was negligible after surgery for both patients. Both CFD and FSI simulations produced airflow results that indicated less effort was needed to breathe after MMA surgery. The FSI simulations demonstrated a substantial decrease in airway deformation after surgery. These beneficial changes positively correlated with the large improvements in polysomnography outcomes after MMA surgery. Copyright © 2018 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  4. Relationship between loss in parenchymal elastic recoil pressure and maximal airway narrowing in subjects with alpha1-antitrypsin deficiency

    NARCIS (Netherlands)

    Cheung, D.; Schot, R.; Zwinderman, A. H.; Zagers, H.; Dijkman, J. H.; Sterk, P. J.

    1997-01-01

    Airway hyperresponsiveness is characterized by an increase in sensitivity and excessive airway narrowing to inhaled bronchoconstrictor stimuli. There is experimental evidence that maximal airway narrowing is related to lung elasticity in normal and asthmatic subjects. We hypothesized that reduced

  5. Running on a lower-body positive pressure treadmill

    DEFF Research Database (Denmark)

    Raffalt, Peter C; Hovgaard-Hansen, Line; Jensen, Bente Rona

    2013-01-01

    This study investigated maximal oxygen consumption (VO2max) and time to exhaustion while running on a lower-body positive pressure treadmill (LBPPT) at normal body weight (BW) as well as how BW support affects respiratory responses, ground reaction forces, and stride characteristics.......This study investigated maximal oxygen consumption (VO2max) and time to exhaustion while running on a lower-body positive pressure treadmill (LBPPT) at normal body weight (BW) as well as how BW support affects respiratory responses, ground reaction forces, and stride characteristics....

  6. HEMODYNAMIC STATUS IN AIRWAY MANAGEMENT DURING GENERAL ANESTHESIA: COMPARISON OF THREE METHODS

    OpenAIRE

    K MONTAZERI; KH NAGHIBI; A.A AKHOUNDI

    2000-01-01

    Introduction. The laryngeal mask airway (LMA) was recently introduced in general anesthesia as an alternative to the face mask or tracheal intubation for airway maintenance. Methods. The effects of LMA insertion, face mask or tracheal intubation on homodynamic status were studied in 195 normotensive patients who underwent elective transurethral lithotripsy (TUL). The patients were monitored with blood pressure measurement and pulse oximetry. Anesthesia was induced with sodium thiopental,...

  7. Influence of bronchial diameter change on the airflow dynamics based on a pressure-controlled ventilation system.

    Science.gov (United States)

    Ren, Shuai; Cai, Maolin; Shi, Yan; Xu, Weiqing; Zhang, Xiaohua Douglas

    2018-03-01

    Bronchial diameter is a key parameter that affects the respiratory treatment of mechanically ventilated patients. In this paper, to reveal the influence of bronchial diameter on the airflow dynamics of pressure-controlled mechanically ventilated patients, a new respiratory system model is presented that combines multigeneration airways with lungs. Furthermore, experiments and simulation studies to verify the model are performed. Finally, through the simulation study, it can be determined that in airway generations 2 to 7, when the diameter is reduced to half of the original value, the maximum air pressure (maximum air pressure in lungs) decreases by nearly 16%, the maximum flow decreases by nearly 30%, and the total airway pressure loss (sum of each generation pressure drop) is more than 5 times the original value. Moreover, in airway generations 8 to 16, with increasing diameter, the maximum air pressure, maximum flow, and total airway pressure loss remain almost constant. When the diameter is reduced to half of the original value, the maximum air pressure decreases by 3%, the maximum flow decreases by nearly 5%, and the total airway pressure loss increases by 200%. The study creates a foundation for improvement in respiratory disease diagnosis and treatment. Copyright © 2017 John Wiley & Sons, Ltd.

  8. Sustained inflation and incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation in a large porcine model of acute respiratory distress syndrome

    Directory of Open Access Journals (Sweden)

    Wunder Christian

    2006-06-01

    Full Text Available Abstract Background To compare the effect of a sustained inflation followed by an incremental mean airway pressure trial during conventional and high-frequency oscillatory ventilation on oxygenation and hemodynamics in a large porcine model of early acute respiratory distress syndrome. Methods Severe lung injury (Ali was induced in 18 healthy pigs (55.3 ± 3.9 kg, mean ± SD by repeated saline lung lavage until PaO2 decreased to less than 60 mmHg. After a stabilisation period of 60 minutes, the animals were randomly assigned to two groups: Group 1 (Pressure controlled ventilation; PCV: FIO2 = 1.0, PEEP = 5 cmH2O, VT = 6 ml/kg, respiratory rate = 30/min, I:E = 1:1; group 2 (High-frequency oscillatory ventilation; HFOV: FIO2 = 1.0, Bias flow = 30 l/min, Amplitude = 60 cmH2O, Frequency = 6 Hz, I:E = 1:1. A sustained inflation (SI; 50 cmH2O for 60s followed by an incremental mean airway pressure (mPaw trial (steps of 3 cmH2O every 15 minutes were performed in both groups until PaO2 no longer increased. This was regarded as full lung inflation. The mPaw was decreased by 3 cmH2O and the animals reached the end of the study protocol. Gas exchange and hemodynamic data were collected at each step. Results The SI led to a significant improvement of the PaO2/FiO2-Index (HFOV: 200 ± 100 vs. PCV: 58 ± 15 and TAli: 57 ± 12; p 2-reduction (HFOV: 42 ± 5 vs. PCV: 62 ± 13 and TAli: 55 ± 9; p Ali: 6.1 ± 1 vs. T75: 3.4 ± 0.4; PCV: TAli: 6.7 ± 2.4 vs. T75: 4 ± 0.5; p Conclusion A sustained inflation followed by an incremental mean airway pressure trial in HFOV improved oxygenation at a lower mPaw than during conventional lung protective ventilation. HFOV but not PCV resulted in normocapnia, suggesting that during HFOV there are alternatives to tidal ventilation to achieve CO2-elimination in an "open lung" approach.

  9. Tracheobronchomegaly associated tracheomalacia: analysis by sleep study.

    Science.gov (United States)

    Sundaram, P; Joshi, J M

    2004-01-01

    Tracheobronchomegaly (TBM) occasionally may progress to extensive tracheomalacia which leads to respiratory failure. Spirometry, dynamic expiratory multidetector computed tomography (CT), bronchoscopy are used to diagnose patients of suspected tracheobronchomalacia. We used the technique of night-time monitoring of respiratory variables to show the presence of respiratory abnormalities during sleep and which was corrected by applying nasal continuous positive airway pressure (CPAP). The study showed the presence of both apnoea and hypopnoeas, which were obstructive in nature with an apnoea-hypopnoea index (AHI) of 11, no snoring and associated oxygen desaturation of 75 per cent. A second overnight study with nasal continuous positive airway pressure at a critical pressure of 8 cm, the AHI decreased to 3 along with no drop in oxygen saturation. This non-invasive technique should be considered as a diagnostic tool in tracheobronchomalacia and to know the outcome of CPAP, surgical or stent therapy in this condition.

  10. Management of the difficult airway.

    Science.gov (United States)

    Schwartz, D E; Wiener-Kronish, J P

    1991-09-01

    For clinicians involved in airway management, a plan of action for dealing with the difficult airway or a failed intubation should be developed well in advance of encountering a patient in whom intubation is not routine. When difficulty is anticipated, the equipment necessary for performing a difficult intubation should be immediately available. It also is prudent to have a surgeon skilled in performing a tracheotomy and a criothyroidotomy stand by. The intubation should be attempted in the awake state, preferably using the fiberoptic bronchoscope. The more challenging situation is when the difficult airway is confronted unexpectedly. After the first failed attempt at laryngoscopy, head position should be checked and the patient ventilated with oxygen by mask. A smaller styletted tube and possibly a different laryngoscope blade should be selected for a second attempt at intubation. The fiberoptic bronchoscope and other equipment for difficult intubation should be obtained. A second attempt should then be made. If this is unsuccessful, the patient should be reoxygenated, and assistance including a skilled anesthesiologist and surgeon should be summoned. On a third attempt, traction to the tongue can be applied by an assistant, a tube changer could be used to enter the larynx, or one of the other special techniques previously described can be used. If this third attempt fails, it may be helpful to have a physician more experienced in airway management attempt intubation after oxygen has been administered to the patient. If all attempts are unsuccessful, then invasive techniques to secure the airway will have to be performed.

  11. Protective effects of valproic acid against airway hyperresponsiveness and airway remodeling in a mouse model of allergic airways disease.

    Science.gov (United States)

    Royce, Simon G; Dang, William; Ververis, Katherine; De Sampayo, Nishika; El-Osta, Assam; Tang, Mimi L K; Karagiannis, Tom C

    2011-12-01

    Airway remodeling and airway hyperresponsiveness are major aspects of asthma pathology that are not targeted optimally by existing anti-inflammatory drugs. Histone deacetylase inhibitors have a wide range of effects that may potentially abrogate aspects of remodeling. One such histone deacetylase inhibitor is valproic acid (2-propylvaleric acid). Valproic acid is used clinically as an anti-epileptic drug and is a potent inhibitor of class I histone deacetylases but also inhibits class II histone deacetylases. We used valproic acid as a molecular model of histone deacetylase inhibition in vivo in chronic allergic airways disease mice with airway remodeling and airway hyperresponsiveness. Wild-type Balb/c mice with allergic airways disease were treated with valproic acid or vehicle control. Airway inflammation was assessed by bronchoalveolar lavage fluid cell counts and examination of lung tissue sections. Remodeling was assessed by morphometric analysis of histochemically stained slides and lung function was assessed by invasive plethysmography measurement of airway resistance. Valproic acid treatment did not affect inflammation parameters; however, valproic acid treatment resulted in reduced epithelial thickness as compared to vehicle treated mice (p < 0.01), reduced subepithelial collagen deposition (p < 0.05) and attenuated airway hyperresponsiveness (p < 0.05 and p < 0.01 for the two highest doses of methacholine, respectively). These findings show that treatment with valproic acid can reduce structural airway remodeling changes and hyperresponsiveness, providing further evidence for the potential use of histone deacetylase inhibitors for the treatment of asthma.

  12. Airway stents

    Science.gov (United States)

    Keyes, Colleen

    2018-01-01

    Stents and tubes to maintain the patency of the airways are commonly used for malignant obstruction and are occasionally employed in benign disease. Malignant airway obstruction usually results from direct involvement of bronchogenic carcinoma, or by extension of carcinomas occurring in the esophagus or the thyroid. External compression from lymph nodes or metastatic disease from other organs can also cause central airway obstruction. Most malignant airway lesions are surgically inoperable due to advanced disease stage and require multimodality palliation, including stent placement. As with any other medical device, stents have significantly evolved over the last 50 years and deserve an in-depth understanding of their true capabilities and complications. Not every silicone stent is created equal and the same holds for metallic stents. Herein, we present an overview of the topic as well as some of the more practical and controversial issues surrounding airway stents. We also try to dispel the myths surrounding stent removal and their supposed use only in central airways. At the end, we come to the long-held conclusion that stents should not be used as first line treatment of choice, but after ruling out the possibility of curative surgical resection or repair. PMID:29707506

  13. The deflation limb of the pressure-volume relationship in infants during high-frequency ventilation.

    Science.gov (United States)

    Tingay, David G; Mills, John F; Morley, Colin J; Pellicano, Anastasia; Dargaville, Peter A

    2006-02-15

    The importance of applying high-frequency oscillatory ventilation with a high lung volume strategy in infants is well established. Currently, a lack of reliable methods for assessing lung volume limits clinicians' ability to achieve the optimum volume range. To map the pressure-volume relationship of the lung during high-frequency oscillatory ventilation in infants, to determine at what point ventilation is being applied clinically, and to describe the relationship between airway pressure, lung volume, and oxygenation. In 12 infants, a partial inflation limb and the deflation limb of the pressure-volume relationship were mapped using a quasi-static lung volume optimization maneuver. This involved stepwise airway pressure increments to total lung capacity, followed by decrements until the closing pressure of the lung was identified. Lung volume and oxygen saturation were recorded at each airway pressure. Lung volume was measured using respiratory inductive plethysmography. A distinct deflation limb could be mapped in each infant. Overall, oxygenation and lung volume were improved by applying ventilation on the deflation limb. Maximal lung volume and oxygenation occurred on the deflation limb at a mean airway pressure of 3 and 5 cm H(2)O below the airway pressure approximating total lung capacity, respectively. Using current ventilation strategies, all infants were being ventilated near the inflation limb. It is possible to delineate the deflation limb in infants receiving high-frequency oscillatory ventilation; in doing so, greater lung volume and oxygenation can be achieved, often at lower airway pressures.

  14. Individual canine Airway Response Variability to a Deep Inspiration

    Directory of Open Access Journals (Sweden)

    Robert H. Brown

    2011-01-01

    Full Text Available In healthy individuals, a DI can reverse (bronchodilation or prevent (bronchoprotection induced airway constriction. For individuals with asthma or COPD, these effects may be attenuated or absent. Previous work showed that the size and duration of a DI affected the subsequent response of the airways. Also, increased airway tone lead to increased airway size variability. The present study examined how a DI affected the temporal variability in individual airway baseline size and after methacholine challenge in dogs using High-Resolution Computed Tomography. Dogs were anesthetized and ventilated, and on 4 separate days, HRCT scans were acquired before and after a DI at baseline and during a continuous intravenous infusion of methacholine (Mch at 3 dose rates (17, 67, and 200 μg/mm. The Coefficient of Variation was used as an index of temporal variability in airway size. We found that at baseline and the lowest dose of Mch, variability decreased immediately and 5 minutes after the DI ( P < 0.0001. In contrast, with higher doses of Mch, the DI caused a variable response. At a rate of 67 μg/min of Mch, the temporal variability increased after 5 minutes, while at a rate of 200 μg/min of Mch, the temporal variability increased immediately after the DI. Increased airway temporal variability has been shown to be associated with asthma. Although the mechanisms underlying this temporal variability are poorly understood, the beneficial effects of a DI to decrease airway temporal variability was eliminated when airway tone was increased. If this effect is absent in asthmatics, this may suggest a possible mechanism for the loss of bronchoprotective and bronchodilatory effects after a DI in asthma.

  15. Continuous positive airway pressure alters cranial blood flow and cerebrospinal fluid dynamics at the craniovertebral junction

    Directory of Open Access Journals (Sweden)

    Theresia I. Yiallourou

    2015-09-01

    Conclusion: Application of CPAP via a full-fitted mask at 15 cm H2O was found to have a significant effect on intracranial venous outflow and spinal CSF flow at the C2 vertebral level in healthy adult-age awake volunteers. CPAP can be used to non-invasively provoke changes in intracranial and CSF flow dynamics.

  16. Continuous production of glycerol by catalytic high pressure hydrogenolysis of sucrose

    NARCIS (Netherlands)

    van Ling, Gerrit; Driessen, Alfons J.; Piet, Arie C.; Vlugter, Jozef C.

    1970-01-01

    Several continuous reactor systems have been discussed for the catalytic high pressure hydrogenolysis of sucrose to glycerol. Theoretically and actually, continuous reactors lead to lower glycerol yields than in a batch process. Two continuous stirred tank reactors in cascade constitute a reasonable

  17. Possible role of differential growth in airway wall remodeling in asthma

    KAUST Repository

    Moulton, D. E.

    2011-01-20

    Possible role of differential growth in airway wall remodeling in asthma. J Appl Physiol 110: 1003-1012, 2011. First published January 20, 2011; doi:10.1152/japplphysiol.00991.2010.- Airway remodeling in patients with chronic asthma is characterized by a thickening of the airway walls. It has been demonstrated in previous theoretical models that this change in thickness can have an important mechanical effect on the properties of the wall, in particular on the phenomenon of mucosal folding induced by smooth muscle contraction. In this paper, we present a model for mucosal folding of the airway in the context of growth. The airway is modeled as a bilayered cylindrical tube, with both geometric and material nonlinearities accounted for via the theory of finite elasticity. Growth is incorporated into the model through the theory of morphoelasticity. We explore a range of growth possibilities, allowing for anisotropic growth as well as different growth rates in each layer. Such nonuniform growth, referred to as differential growth, can change the properties of the material beyond geometrical changes through the generation of residual stresses. We demonstrate that differential growth can have a dramatic impact on mucosal folding, in particular on the critical pressure needed to induce folding, the buckling pattern, as well as airway narrowing. We conclude that growth may be an important component in airway remodeling. Copyright © 2011 the American Physiological Society.

  18. CPAP Tips

    Medline Plus

    Full Text Available ... opinion count. Sign in ... and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from the U.S. Food and Drug Administration (FDA) on how to safely ...

  19. Cuffless and Continuous Blood Pressure Estimation from the Heart Sound Signals

    Directory of Open Access Journals (Sweden)

    Rong-Chao Peng

    2015-09-01

    Full Text Available Cardiovascular disease, like hypertension, is one of the top killers of human life and early detection of cardiovascular disease is of great importance. However, traditional medical devices are often bulky and expensive, and unsuitable for home healthcare. In this paper, we proposed an easy and inexpensive technique to estimate continuous blood pressure from the heart sound signals acquired by the microphone of a smartphone. A cold-pressor experiment was performed in 32 healthy subjects, with a smartphone to acquire heart sound signals and with a commercial device to measure continuous blood pressure. The Fourier spectrum of the second heart sound and the blood pressure were regressed using a support vector machine, and the accuracy of the regression was evaluated using 10-fold cross-validation. Statistical analysis showed that the mean correlation coefficients between the predicted values from the regression model and the measured values from the commercial device were 0.707, 0.712, and 0.748 for systolic, diastolic, and mean blood pressure, respectively, and that the mean errors were less than 5 mmHg, with standard deviations less than 8 mmHg. These results suggest that this technique is of potential use for cuffless and continuous blood pressure monitoring and it has promising application in home healthcare services.

  20. Pressure breathing in fighter aircraft for G accelerations and loss of cabin pressurization at altitude--a brief review.

    Science.gov (United States)

    Lauritzsen, Lars P; Pfitzner, John

    2003-04-01

    The purpose of this brief review is to outline the past and present use of pressure breathing, not by patients but by fighter pilots. Of the historical and recent references quoted, most are from aviation-medicine journals that are not often readily available to anesthesiologists. Pressure breathing at moderate levels of airway pressure gave World War II fighter pilots a tactical altitude advantage. With today's fast and highly maneuverable jet fighters, very much higher airway pressures of the order of 8.0 kPa (identical with 60 mmHg) are used. They are used in conjunction with a counterpressure thoracic vest and an anti-G suit for the abdomen and lower body. Pressurization is activated automatically in response to +Gz accelerations, and to a potentially catastrophic loss of cabin pressurization at altitude. During +Gz accelerations, pressure breathing has been shown to maintain cerebral perfusion by raising the systemic arterial pressure, so increasing the level of G-tolerance that is afforded by the use of anti-G suits and seat tilt-back angles alone. This leaves the pilot less reliant on rigorous, and potentially distracting, straining maneuvers. With loss of cabin pressurization at altitude, pressure breathing of 100% oxygen at high airway pressures enables the pilot's alveolar PO(2) to be maintained at a safe level during emergency descent. Introduced in military aviation, pressure breathing for G-tolerance and pressure breathing for altitude presented as concepts that may be of general physiological interest to many anesthesiologists.

  1. Asystole following positive pressure insufflation of right pleural cavity: a case report

    Directory of Open Access Journals (Sweden)

    Konia Mojca R

    2011-06-01

    Full Text Available Abstract Introduction Adverse hemodynamic effects with severe bradycardia have been previously reported during positive pressure insufflation of the right thoracic cavity in humans. To the best of our knowledge, this is the first report of asystole during thoracoscopic surgery with positive pressure insufflation. Case presentation A 63-year-old Caucasian woman developed asystole at the onset of positive pressure insufflation of her right hemithorax during a thoracoscopic single-lung ventilation procedure. Immediate deflation of pleural cavity, intravenous glycopyrrolate and atropine administration returned her heart rhythm to normal sinus rhythm. The surgery proceeded in the absence of positive pressure insufflation without any further complications. Conclusions We discuss the proposed mechanisms of hemodynamic instability with positive pressure thoracic insufflation, and anesthetic and insufflation techniques that decrease the likelihood of adverse hemodynamic events.

  2. Degrees of reality: airway anatomy of high-fidelity human patient simulators and airway trainers.

    Science.gov (United States)

    Schebesta, Karl; Hüpfl, Michael; Rössler, Bernhard; Ringl, Helmut; Müller, Michael P; Kimberger, Oliver

    2012-06-01

    Human patient simulators and airway training manikins are widely used to train airway management skills to medical professionals. Furthermore, these patient simulators are employed as standardized "patients" to evaluate airway devices. However, little is known about how realistic these patient simulators and airway-training manikins really are. This trial aimed to evaluate the upper airway anatomy of four high-fidelity patient simulators and two airway trainers in comparison with actual patients by means of radiographic measurements. The volume of the pharyngeal airspace was the primary outcome parameter. Computed tomography scans of 20 adult trauma patients without head or neck injuries were compared with computed tomography scans of four high-fidelity patient simulators and two airway trainers. By using 14 predefined distances, two cross-sectional areas and three volume parameters of the upper airway, the manikins' similarity to a human patient was assessed. The pharyngeal airspace of all manikins differed significantly from the patients' pharyngeal airspace. The HPS Human Patient Simulator (METI®, Sarasota, FL) was the most realistic high-fidelity patient simulator (6/19 [32%] of all parameters were within the 95% CI of human airway measurements). The airway anatomy of four high-fidelity patient simulators and two airway trainers does not reflect the upper airway anatomy of actual patients. This finding may impact airway training and confound comparative airway device studies.

  3. Mask pressure effects on the nasal bridge during short-term noninvasive ventilation

    Science.gov (United States)

    Brill, Anne-Kathrin; Pickersgill, Rachel; Moghal, Mohammad; Morrell, Mary J.; Simonds, Anita K.

    2018-01-01

    The aim of this study was to assess the influence of different masks, ventilator settings and body positions on the pressure exerted on the nasal bridge by the mask and subjective comfort during noninvasive ventilation (NIV). We measured the pressure over the nasal bridge in 20 healthy participants receiving NIV via four different NIV masks (three oronasal masks, one nasal mask) at three different ventilator settings and in the seated or supine position. Objective pressure measurements were obtained with an I-Scan pressure-mapping system. Subjective comfort of the mask fit was assessed with a visual analogue scale. The masks exerted mean pressures between 47.6±29 mmHg and 91.9±42.4 mmHg on the nasal bridge. In the supine position, the pressure was lower in all masks (57.1±31.9 mmHg supine, 63.9±37.3 mmHg seated; pmasks, a change of inspiratory positive airway pressure (IPAP) did not influence the objective pressure over the nasal bridge. Subjective discomfort was associated with higher IPAP and positively correlated with the pressure on the skin. Objective measurement of pressure on the skin during mask fitting might be helpful for mask selection. Mask fitting in the supine position should be considered in the clinical routine. PMID:29637077

  4. Incidence of unanticipated difficult airway using an objective airway score versus a standard clinical airway assessment

    DEFF Research Database (Denmark)

    Nørskov, Anders Kehlet; Rosenstock, Charlotte Valentin; Wetterslev, Jørn

    2013-01-01

    -specific assessment. Data from patients' pre-operative airway assessment are registered in the Danish Anaesthesia Database. Objective scores for intubation and mask ventilation grade the severity of airway managements. The accuracy of predicting difficult intubation and mask ventilation is measured for each group...... the examination and registration of predictors for difficult mask ventilation with a non-specified clinical airway assessment on prediction of difficult mask ventilation.Method/Design: We cluster-randomized 28 Danish departments of anaesthesia to airway assessment either by the SARI or by usual non...... that registration of the SARI and predictors for difficult mask ventilation are mandatory for the intervention group but invisible to controls....

  5. Positioning bedridden patients to reduce interface pressures over the sacrum and great trochanter.

    Science.gov (United States)

    Yoshikawa, Y; Maeshige, N; Sugimoto, M; Uemura, M; Noguchi, M; Terashi, H

    2015-07-01

    In this study, we evaluated the effect of hip-joint rotation on the interface pressure over the sacrum and greater trochanter with a new protocol for positioning of bedridden elderly patients. The interface pressure values over the sacrum and greater trochanter in bedridden patients were evaluated. These were collected in the supine position, 90° lateral position, and 30° and 40° laterally inclined positions with external rotation or neutral positioning of the hip joint. Each interface pressure was assessed with a device measuring pressure distribution, after which, the peak pressure index (PPI) was calculated. In the 17 patients examined, the PPI over the sacrum in the supine position was significantly greater than that in other positions. In the 30° and 40° laterally inclined positions, the PPIs over the greater trochanter were significantly lower in the neutral position of the hip joint compared with those in the external rotation position. Our findings revealed the effects of hip-joint rotation on the interface pressure for the greater trochanter, possibly due to the increased distance between the greater trochanter and the sacrum caused by neutral position of the hip joint. The results demonstrate that it is to best place the hip joint in a neutral position when the legs are in contact with the bed in order to distribute the pressure over the greater trochanter in the 30° and 40° laterally inclined positions. These results can be applied to the clinical setting to improve patient positioning and decrease pressure ulcers. The authors declare that they have no competing financial interests.

  6. "COMPARISON OF HEMODYNAMIC CHANGES AFTER INSERTION OF LARYNGEAL MASK AIRWAY, FACEMASK AND ENDOTRACHEAL INTUBATION"

    Directory of Open Access Journals (Sweden)

    K. Montazari

    2004-11-01

    Full Text Available Hemodynamic changes are major hazards of general anesthesia and are probably generated by direct laryngoscopy and endotracheal intubation. We designed this prospective randomised study to assess the cardiovascular changes after either laryngeal mask airway (LMA, face mask (FM or endotracheal tube (ETT insertion in the airway management of adult patients anesthetised with nitrous oxide and halothane. A total of 195 healthy normotensive adult patients with normal airways were randomly assigned to one of the three groups according to their airway management (n= 65 each for transurethral lithotripsy procedures. Heart rate (HR, systolic blood pressure (SBP, diastolic blood pressure (DBP and mean arterial blood pressure (MAP values were recorded before the induction of anesthesia, and then every three minutes until 30 min thereafter. The mean maximum HR and MAP values obtained during 15 and 30 minutes after insertion of LMA were 81±13, 73±8 bpm and 82±14, 79 ±11 mmHg, respectively which were significantly smaller compared to those with FM (84±12, 80±6 bpm and 86±10, 83±13 mmHg and ETT (96±8, 88±7 bpm and 91±11, 82±9 mmHg (P< 0.05. Direct stimulation of the trachea appears to be a major cause of the hemodynamic changes associated with tracheal intubation during general anesthesia, but why hemodynamic changes in LMA were smaller than facemask needs further study. In healthy normotensive patients the use of LMA for the airway management during general anesthesia results in a smaller cardiovascular change than FM and ETT.

  7. Intratracheal Administration of Mesenchymal Stem Cells Modulates Tachykinin System, Suppresses Airway Remodeling and Reduces Airway Hyperresponsiveness in an Animal Model.

    Directory of Open Access Journals (Sweden)

    Konrad Urbanek

    Full Text Available The need for new options for chronic lung diseases promotes the research on stem cells for lung repair. Bone marrow-derived mesenchymal stem cells (MSCs can modulate lung inflammation, but the data on cellular processes involved in early airway remodeling and the potential involvement of neuropeptides are scarce.To elucidate the mechanisms by which local administration of MSCs interferes with pathophysiological features of airway hyperresponsiveness in an animal model.GFP-tagged mouse MSCs were intratracheally delivered in the ovalbumin mouse model with subsequent functional tests, the analysis of cytokine levels, neuropeptide expression and histological evaluation of MSCs fate and airway pathology. Additionally, MSCs were exposed to pro-inflammatory factors in vitro.Functional improvement was observed after MSC administration. Although MSCs did not adopt lung cell phenotypes, cell therapy positively affected airway remodeling reducing the hyperplastic phase of the gain in bronchial smooth muscle mass, decreasing the proliferation of epithelium in which mucus metaplasia was also lowered. Decrease of interleukin-4, interleukin-5, interleukin-13 and increase of interleukin-10 in bronchoalveolar lavage was also observed. Exposed to pro-inflammatory cytokines, MSCs upregulated indoleamine 2,3-dioxygenase. Moreover, asthma-related in vivo upregulation of pro-inflammatory neurokinin 1 and neurokinin 2 receptors was counteracted by MSCs that also determined a partial restoration of VIP, a neuropeptide with anti-inflammatory properties.Intratracheally administered MSCs positively modulate airway remodeling, reduce inflammation and improve function, demonstrating their ability to promote tissue homeostasis in the course of experimental allergic asthma. Because of a limited tissue retention, the functional impact of MSCs may be attributed to their immunomodulatory response combined with the interference of neuropeptide system activation and tissue

  8. Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients.

    Science.gov (United States)

    Girgis, Karim K; Youssef, Maha M I; ElZayyat, Nashwa S

    2014-10-01

    One of the methods proposed in cases of difficult airway management in children is using a supraglottic airway device as a conduit for tracheal intubation. The aim of this study was to compare the efficacy of the Air-Q Intubating Laryngeal Airway (Air-Q) and the Cobra Perilaryngeal Airway (CobraPLA) to function as a conduit for fiber optic-guided tracheal intubation in pediatric patients. A total of 60 children with ages ranging from 1 to 6 years, undergoing elective surgery, were randomized to have their airway managed with either an Air-Q or CobraPLA. Outcomes recorded were the success rate, time and number of attempts required for fiber optic-guided intubation and the time required for device removal after intubation. We also recorded airway leak pressure (ALP), fiber optic grade of glottic view and occurrence of complications. Both devices were successfully inserted in all patients. The intubation success rate was comparable with the Air-Q and the CobraPLA (96.7% vs. 90%), as was the first attempt success rate (90% vs. 80%). The intubation time was significantly longer with the CobraPLA (29.5 ± 10.9 s vs. 23.2 ± 9.8 s; P fiber optic grade of glottic view was comparable with the two devices. The CobraPLA was associated with a significantly higher incidence of blood staining of the device on removal and post-operative sore throat. Both the Air-Q and CobraPLA can be used effectively as a conduit for fiber optic-guided tracheal intubation in children. However, the Air-Q proved to be superior due to a shorter intubation time and less airway morbidity compared with the CobraPLA.

  9. Application of Dual Mask for Postoperative Respiratory Support in Obstructive Sleep Apnea Patient

    Directory of Open Access Journals (Sweden)

    Jahan Porhomayon

    2013-01-01

    Full Text Available In some conditions continuous positive airway pressure (CPAP or bilevel positive airway pressure (BIPAP therapy alone fails to provide satisfactory oxygenation. In these situations oxygen (O2 is often being added to CPAP/BIPAP mask or hose. Central sleep apnea and obstructive sleep apnea (OSA are often present along with other chronic conditions, such as chronic obstructive pulmonary disease (COPD, congestive heart failure, pulmonary fibrosis, neuromuscular disorders, chronic narcotic use, or central hypoventilation syndrome. Any of these conditions may lead to the need for supplemental O2 administration during the titration process. Maximization of comfort, by delivering O2 directly via a nasal cannula through the mask, will provide better oxygenation and ultimately treat the patient with lower CPAP/BIPAP pressure.

  10. The Role of Heated Humidified High-flow Nasal Cannula as Noninvasive Respiratory Support in Neonates

    Directory of Open Access Journals (Sweden)

    Ke-Yun Chao

    2017-08-01

    Full Text Available Recently, heated humidified high-flow nasal cannula (HHHFNC has been introduced and applied as a noninvasive respiratory support in neonates. Although HHHFNC is widely used in neonates presenting with respiratory distress, the efficiency and safety when compared with nasal continuous positive airway pressure or noninvasive positive pressure ventilation are still controversial. This review aims to evaluate the performance and applications of HHHFNC in neonates.

  11. Comparisons of different mean airway pressure settings during high-frequency oscillation in inflammatory response to oleic acid-induced lung injury in rabbits

    Directory of Open Access Journals (Sweden)

    Koichi Ono

    2009-03-01

    Full Text Available Koichi Ono1, Tomonobu Koizumi2, Rikimaru Nakagawa1, Sumiko Yoshikawa2, Tetsutarou Otagiri11Department of Anesthesiology and Resuscitation; 2First Department of Internal Medicine, Shinshu University School of Medicine, Matsumoto, JapanPurpose: The present study was designed to examine effects of different mean airway pressure (MAP settings during high-frequency oscillation (HFO on oxygenation and inflammatory responses to acute lung injury (ALI in rabbits.Methods: Anesthetized rabbits were mechanically ventilated with a conventional mechanical ventilation (CMV mode (tidal volume 6 ml/kg, inspired oxygen fraction [FIo2] of 1.0, respiratory rate [RR] of 30/min, positive end-expiratory pressure [PEEP] of 5 cmH2O. ALI was induced by intravenous administration of oleic acid (0.08 ml/kg and the animals were randomly allocated to the following three experimental groups; animals (n = 6 ventilated using the same mode of CMV, or animals ventilated with standard MAP (MAP 10 cmH2O, n = 7, and high MAP (15 cmH2O, n = 6 settings of HFO (Hz 15. The MAP settings were calculated by the inflation limb of the pressure-volume curve during CMV.Results: HFO with a high MAP setting significantly improved the deteriorated oxygenation during oleic acid-induced ALI and reduced wet/dry ratios, neutrophil counts and interleukin-8 concentration in bronchoalveolar lavage fluid, compared to those parameters in CMV and standard MAP-HFO.Conclusions: These findings suggest that only high MAP setting during HFO could contribute to decreased lung inflammation as well as improved oxygenation during the development of ALI.Keywords: lung protective ventilation, open lung ventilation, IL-8, neutrophil

  12. "The comparison between effects of two general anesthesia techniques; Intermittent apenic technique and continuous controlled ventilation in upper airway Laser therapy "

    Directory of Open Access Journals (Sweden)

    Khagavy MR "

    2002-11-01

    Full Text Available Introduction: Laser beam due to finest of incision and reduction of postoperative complication, facilitates airway surgery, but at the same time it increases the danger or firing and the airway management and protection becomes difficult during anesthesia. In this study, two general anesthesia methods; (Intermittent Apneic Technique And Continuous Controlled Ventilation With Enveloped Endotracheal Tube have been compared with each other mater. Materials and methods: two groups, each consist of 25 patients 10 to 60 years old, and ASA I-II class and below 100kg weight who have been candidate for laser therapy, were given two mentioned methods of anesthesia. All patients were suffering from subglotic stenosis, vocal cord nodules, papillomatosis and oropharyngeal obstruction. Induction and maintenance of anesthesia, and monitoring during surgery (EGG, PETCO2, SaPo2, BP, PR in both groups were the same. Results: Homodynamic stability in the both groups were the same and there was no hypoxia and dysrhythmia. In apneic technique group, most of the surgeries needed 2-3 time of apnea, and each apnea duration was 2-4 minutes, without any hypercaphic (Peteco 2>47 mmHg and hypoxic (Spo2<90 percent state and duration of laser surgery was about 9-10 minutes. More satisfaction was gained with apneic technique because of having a better surgery filed. All the patients had no recall at the end of anesthesia and patietn's expenses were much lower with no danger of firing. Conclusion: It has been concluded that intermittent apneic technique in upper airway laser therapy is a better technique of anesthesia.

  13. Noninvasive ventilation.

    Science.gov (United States)

    Rabatin, J T; Gay, P C

    1999-08-01

    Noninvasive ventilation refers to the delivery of assisted ventilatory support without the use of an endotracheal tube. Noninvasive positive pressure ventilation (NPPV) can be delivered by using a volume-controlled ventilator, a pressure-controlled ventilator, a bilevel positive airway pressure ventilator, or a continuous positive airway pressure device. During the past decade, there has been a resurgence in the use of noninvasive ventilation, fueled by advances in technology and clinical trials evaluating its use. Several manufacturers produce portable devices that are simple to operate. This review describes the equipment, techniques, and complications associated with NPPV and also the indications for both short-term and long-term applications. NPPV clearly represents an important addition to the techniques available to manage patients with respiratory failure. Future clinical trials evaluating its many clinical applications will help to define populations of patients most apt to benefit from this type of treatment.

  14. Lung recruitability is better estimated according to the Berlin definition of acute respiratory distress syndrome at standard 5 cm H2O rather than higher positive end-expiratory pressure: a retrospective cohort study.

    Science.gov (United States)

    Caironi, Pietro; Carlesso, Eleonora; Cressoni, Massimo; Chiumello, Davide; Moerer, Onner; Chiurazzi, Chiara; Brioni, Matteo; Bottino, Nicola; Lazzerini, Marco; Bugedo, Guillermo; Quintel, Michael; Ranieri, V Marco; Gattinoni, Luciano

    2015-04-01

    The Berlin definition of acute respiratory distress syndrome has introduced three classes of severity according to PaO2/FIO2 thresholds. The level of positive end-expiratory pressure applied may greatly affect PaO2/FIO2, thereby masking acute respiratory distress syndrome severity, which should reflect the underlying lung injury (lung edema and recruitability). We hypothesized that the assessment of acute respiratory distress syndrome severity at standardized low positive end-expiratory pressure may improve the association between the underlying lung injury, as detected by CT, and PaO2/FIO2-derived severity. Retrospective analysis. Four university hospitals (Italy, Germany, and Chile). One hundred forty-eight patients with acute lung injury or acute respiratory distress syndrome according to the American-European Consensus Conference criteria. Patients underwent a three-step ventilator protocol (at clinical, 5 cm H2O, or 15 cm H2O positive end-expiratory pressure). Whole-lung CT scans were obtained at 5 and 45 cm H2O airway pressure. Nine patients did not fulfill acute respiratory distress syndrome criteria of the novel Berlin definition. Patients were then classified according to PaO2/FIO2 assessed at clinical, 5 cm H2O, or 15 cm H2O positive end-expiratory pressure. At clinical positive end-expiratory pressure (11±3 cm H2O), patients with severe acute respiratory distress syndrome had a greater lung tissue weight and recruitability than patients with mild or moderate acute respiratory distress syndrome (pBerlin definition of acute respiratory distress syndrome assessed at 5 cm H2O allows a better evaluation of lung recruitability and edema than at higher positive end-expiratory pressure clinically set.

  15. Strategies to prevent positioning-related complications associated with the lateral suboccipital approach.

    Science.gov (United States)

    Furuno, Yuichi; Sasajima, Hiroyasu; Goto, Yukihiro; Taniyama, Ichita; Aita, Kazuyasu; Owada, Kei; Tatsuzawa, Kazunori; Mineura, Katsuyoshi

    2014-02-01

    The lateral positioning used for the lateral suboccipital surgical approach is associated with various pathophysiologic complications. Strategies to avoid complications including an excessive load on the cervical vertebra and countermeasures against pressure ulcer development are needed. We retrospectively investigated positioning-related complications in 71 patients with cerebellopontine angle lesions undergoing surgery in our department between January 2003 and December 2010 using the lateral suboccipital approach. One patient postoperatively developed rhabdomyolysis, and another presented with transient peroneal nerve palsy on the unaffected side. Stage I and II pressure ulcers were noted in 22 and 12 patients, respectively, although neither stage III nor more severe pressure ulcers occurred. No patients experienced cervical vertebra and spinal cord impairments, brachial plexus palsy, or ulnar nerve palsy associated with rotation and flexion of the neck. Strategies to prevent positioning-related complications, associated with lateral positioning for the lateral suboccipital surgical approach, include the following: atraumatic fixation of the neck focusing on jugular venous perfusion and airway pressure, trunk rotation, and sufficient relief of weightbearing and protection of nerves including the peripheral nerves of all four extremities.

  16. CPAP Tips

    Medline Plus

    Full Text Available ... Published on Dec 12, 2012 Do you have sleep apnea and use a continuous positive airway pressure ( ... 29 Airing: The world's first micro- CPAP for sleep apnea - Duration: 4:26. Airing 461,197 views ...

  17. CPAP Tips

    Medline Plus

    Full Text Available ... Published on Dec 12, 2012 Do you have sleep apnea and use a continuous positive airway pressure ( ... next Airing: The world's first micro- CPAP for sleep apnea - Duration: 4:26. Airing 451,354 views ...

  18. CPAP Tips

    Medline Plus

    Full Text Available ... Published on Dec 12, 2012 Do you have sleep apnea and use a continuous positive airway pressure ( ... next Airing: The world's first micro- CPAP for sleep apnea - Duration: 4:26. Airing 415,550 views ...

  19. CPAP Tips

    Medline Plus

    Full Text Available ... to a playlist. Sign in Share More Report Need to report the video? Sign in to report ... Published on Dec 12, 2012 Do you have sleep apnea and use a continuous positive airway pressure ( ...

  20. Effects of oral appliances and CPAP on the left ventricle and natriuretic peptides

    NARCIS (Netherlands)

    Hoekema, Aarnoud; Voors, Adriaan A.; Wijkstra, Peter J.; Stegenga, Boudewijn; van der Hoeven, Johannes H.; Tol, Cornelis G.; de Bont, Lambert G. M.

    2008-01-01

    Background: In patients without cardiac disease, obstructive sleep apnea-hypopnea syndrome (OSAHS) is associated with systolic and diastolic dysfunction and left ventricular hypertrophy. Although continuous positive airway pressure ( CPAP) therapy has been demonstrated to improve left ventricular

  1. CPAP Tips

    Medline Plus

    Full Text Available ... Published on Dec 12, 2012 Do you have sleep apnea and use a continuous positive airway pressure ( ... next Airing: The world's first micro- CPAP for sleep apnea - Duration: 4:26. Airing 446,529 views ...

  2. A new method of maintaining airway during nasotracheal intubation--the hand mask technique.

    Science.gov (United States)

    Wu, R S; Wong, D S; Chung, P C; Tan, P P

    1993-09-01

    The efficacy of a new method (The hand mask technique) for airway maintenance during nasotracheal intubation was evaluated in our randomized crossover study. Sixty, age less than 50, ASA physical status class I-II patients undergoing surgery for the extremities with informed consent were randomly chosen for the study. Pulse oximeter, capnometer, EKG, blood pressure monitor and a peripheral nerve stimulator were attached to the patients before induction for continuous monitoring. An arterial cannula was inserted for intermittent blood gas sampling. After baseline room air blood gas data had been obtained from the spontaneously breathing patients, a flow rate of 6L/min pure oxygen was applied through a loosely fitted face mask and a semi-closed anesthesia breathing circuit for a period of 5 minutes. An arterial blood sample was drawn and the patients were put under general anesthesia with full muscle relaxation thereafter. Patients were then randomly assigned into two groups according to the ventilation technique used. Group A patients (n = 30) were manually ventilated first through a face mask for ten minutes and then the hand mask technique for another ten minutes. Blood gas data was sampled and heart rate, blood pressure, peak inspiratory airway pressure and end tidal CO2 were recorded immediately after each ventilation technique. For patients in Group B (n = 30), the sequence of the two ventilation technique were reversed. The results showed significant increases in PaO2 after artificial ventilation in both groups (No significant difference in results between the two groups) and less incidence of nasal bleeding in Group A.(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Contrastive Analysis and Research on Negative Pressure Beam Tube System and Positive Pressure Beam Tube System for Mine Use

    Science.gov (United States)

    Wang, Xinyi; Shen, Jialong; Liu, Xinbo

    2018-01-01

    Against the technical defects of universally applicable beam tube monitoring system at present, such as air suction in the beam tube, line clogging, long sampling time, etc., the paper analyzes the current situation of the spontaneous combustion fire disaster forecast of mine in our country and these defects one by one. On this basis, the paper proposes a research thought that improving the positive pressure beam tube so as to substitute the negative pressure beam tube. Then, the paper introduces the beam tube monitoring system based on positive pressure technology through theoretical analysis and experiment. In the comparison with negative pressure beam tube, the paper concludes the advantage of the new system and draws the conclusion that the positive pressure beam tube is superior to the negative pressure beam tube system both in test result and test time. At last, the paper proposes prospect of the beam tube monitoring system based on positive pressure technology.

  4. Rapid Onset Acute Epiglottitis Leading to Negative Pressure Pulmonary Edema

    Directory of Open Access Journals (Sweden)

    V Saraswat

    2007-01-01

    Full Text Available Pulmonary edema is a potentially life-threatening complication of acute airway obstruction. It develops rapidly, without warning, in young healthy individuals. Two forms of post-obstructive pulmonary edema (POPE (also known as negative pressure pulmonary edema, NPPE have been identified. POPE I follows sudden, severe upper airway obstruction. POPE II occurs following surgical relief of chronic upper airway obstruction. Treatment for both is supportive. Full and rapid recovery can be expected with appropriate management. A case report of a middle aged man with acute onset epiglottitis who developed negative pressure pulmonary edema after intubation is presented. The report includes a brief discussion on etiology, clinical features and management dilemma of acute upper airway obstruction.

  5. GH-secreting pituitary macroadenoma (acromegaly) associated with progressive dental malocclusion and refractory CPAP treatment.

    Science.gov (United States)

    Miranda-Rius, Jaume; Brunet-LLobet, Lluís; Lahor-Soler, Eduard; de Dios-Miranda, David; Giménez-Rubio, Josep Anton

    2017-05-10

    A link between progressive dental malocclusion, the use of a continuous positive airway pressure mask and GH-secreting pituitary macroadenoma (acromegaly) has not been previously reported. The present clinicopathological analysis stresses that tooth malposition should not be seen exclusively as a local process. A 62-year-old caucasian man with no relevant medical history reported difficulty chewing food and perceived voice alteration during his annual periodontal check-up. He also referred stiffness of the tongue, face, and submandibular area. The patient had been diagnosed with obstructive sleep apnea syndrome two years previously, since when he had worn a continuous positive airway pressure device during sleep. Exploration of the occlusion revealed significant changes: an atypical left lateral and anterior open bite with major buccoversion of teeth 33, 34, 35, 36. Inspection of the soft tissue revealed only macroglossia, although external palpation indicated a subcutaneous stiffness of the submandibular area. General analytical tests, including hormone profiles, and magnetic resonance imaging confirmed the diagnosis of acromegaly induced by a pituitary adenoma. Intrasellar tumor resection via transsphenoidal approach was performed. After surgery, the patient already noted a marked improvement of all symptoms associated with the acromegaly. Desaturation data also evolved favourably and the pulmonologist advised the patient to abandon the continuous positive airway pressure treatment. Progressive dental malocclusion may be associated with a systemic disease and the use of a nasal mask with premaxillary support may distort the diagnosis of acromegaly.

  6. Driving ability in sleep apnoea patients before and after CPAP treatment: evaluation on a road safety platform.

    Science.gov (United States)

    Mazza, S; Pépin, J-L; Naëgelé, B; Rauch, E; Deschaux, C; Ficheux, P; Lévy, P

    2006-11-01

    Sleepiness is considered to be the major cause of increased traffic accidents in patients with obstructive sleep apnoea syndrome (OSAS). Until now, OSAS patients' driving ability has been assessed using driving simulators, but no assessment in a more natural driving environment has been carried out to date. The aim of the present study was to evaluate driving parameters in OSAS and in controls on a road safety platform, and to compare them with attentional in-laboratory measures before and after continuous positive airway pressure treatment. The parameters measured were: reaction time; distance to stop and number of collisions on the platform; maintenance of wakefulness; and sustained, selective and divided attention in laboratory. Patients exhibited much longer reaction times than controls, leading to a lengthening of the vehicle's stopping distance of 8.8 m at 40 km.h(-1) and to twice the number of collisions. Patients did not demonstrate objective sleepiness or selective and sustained attention deficits. Divided attention deficits were found. However, they did not allow the prediction of real driving impairment. After CPAP treatment, there was no longer any difference between patients and controls regarding driving and attention performances. Driving abilities are significantly impaired in obstructive sleep apnoea syndrome. After continuous positive airway pressure treatment, deficits were normalised. This stresses the importance of evaluating attentional parameters in apnoeic patients and of offering continuous positive airway pressure treatment even to non-sleepy subjects.

  7. Gestational trophoblastic neoplasm and women living with HIV and ...

    African Journals Online (AJOL)

    2015-07-03

    Jul 3, 2015 ... smart phone or mobile device to read online. .... problematic and a continuous positive airway pressure ... that survival is prolonged with the use of ART.3,7 ... relationships which may have inappropriately influenced them in ...

  8. CPAP Tips

    Medline Plus

    Full Text Available ... Published on Dec 12, 2012 Do you have sleep apnea and use a continuous positive airway pressure ( ... views 3:08 The straight honest truth about Sleep Apnea and CPAP - Duration: 14:51. angelhelp777 624, ...

  9. Conceptual Study of LSTAT Integration to Robotics and Other Advanced Medical Technologies

    Science.gov (United States)

    2004-07-31

    Ballistic Impact Detection CDDS Clinical Decision-Support System CPAP Continuous Positive Airway Pressure CRT Cathode Ray Tube CSH Combat Support...by soldier non-volatile flash memory various commercial technologies available referred to as electronic information carrier (EIC) or

  10. CPAP Tips

    Science.gov (United States)

    ... now Try it free Find out why Close CPAP Tips from FDA USFoodandDrugAdmin Loading... Unsubscribe from USFoodandDrugAdmin? ... apnea and use a continuous positive airway pressure (CPAP) device when sleeping? Here are some tips from ...

  11. CPAP Tips

    Medline Plus

    Full Text Available ... Published on Dec 12, 2012 Do you have sleep apnea and use a continuous positive airway pressure ( ... views 3:08 The straight honest truth about Sleep Apnea and CPAP - Duration: 14:51. angelhelp777 622, ...

  12. CPAP Tips

    Medline Plus

    Full Text Available ... Published on Dec 12, 2012 Do you have sleep apnea and use a continuous positive airway pressure ( ... views 2:02 The straight honest truth about Sleep Apnea and CPAP - Duration: 14:51. angelhelp777 623, ...

  13. Noninvasive assessment of pulmonary vascular and airway response to physiologic stimuli with high-resolution CT

    International Nuclear Information System (INIS)

    Herold, C.J.; Wetzel, R.C.; Herold, S.M.; Martin, L.; Zerhouni, E.A.; Robotham, J.

    1990-01-01

    This paper reports on reactivity of pulmonary vasculature under various stimuli studied invasively with perfused isolated lung models. We used high- resolution CT (HRCT) to demonstrate noninvasively the effects of hypoxia and volume variation on pulmonary circulation and airways. Five anesthetized and ventilated pigs were examined with HRCT (10 contiguous 2-mm sections through the lower lobes) during varying oxygen tensions and intravascular volume states. Blood pressures, pulmonary artery pressures, blood gas levels, and cardiac indexes (thermodilution) were measured. HRCT scans were digitized, and vessel and airway areas were determined with use of a computer edging process

  14. Airway resistance at maximum inhalation as a marker of asthma and airway hyperresponsiveness

    Directory of Open Access Journals (Sweden)

    O'Connor George T

    2011-07-01

    Full Text Available Abstract Background Asthmatics exhibit reduced airway dilation at maximal inspiration, likely due to structural differences in airway walls and/or functional differences in airway smooth muscle, factors that may also increase airway responsiveness to bronchoconstricting stimuli. The goal of this study was to test the hypothesis that the minimal airway resistance achievable during a maximal inspiration (Rmin is abnormally elevated in subjects with airway hyperresponsiveness. Methods The Rmin was measured in 34 nonasthmatic and 35 asthmatic subjects using forced oscillations at 8 Hz. Rmin and spirometric indices were measured before and after bronchodilation (albuterol and bronchoconstriction (methacholine. A preliminary study of 84 healthy subjects first established height dependence of baseline Rmin values. Results Asthmatics had a higher baseline Rmin % predicted than nonasthmatic subjects (134 ± 33 vs. 109 ± 19 % predicted, p = 0.0004. Sensitivity-specificity analysis using receiver operating characteristic curves indicated that baseline Rmin was able to identify subjects with airway hyperresponsiveness (PC20 min % predicted, FEV1 % predicted, and FEF25-75 % predicted, respectively. Also, 80% of the subjects with baseline Rmin min > 145% predicted had hyperresponsive airways, regardless of clinical classification as asthmatic or nonasthmatic. Conclusions These findings suggest that baseline Rmin, a measurement that is easier to perform than spirometry, performs as well as or better than standard spirometric indices in distinguishing subjects with airway hyperresponsiveness from those without hyperresponsive airways. The relationship of baseline Rmin to asthma and airway hyperresponsiveness likely reflects a causal relation between conditions that stiffen airway walls and hyperresponsiveness. In conjunction with symptom history, Rmin could provide a clinically useful tool for assessing asthma and monitoring response to treatment.

  15. Technology for noninvasive mechanical ventilation: looking into the black box

    Directory of Open Access Journals (Sweden)

    Ramon Farré

    2016-03-01

    Full Text Available Current devices for providing noninvasive respiratory support contain sensors and built-in intelligence for automatically modifying ventilation according to the patient's needs. These devices, including automatic continuous positive airway pressure devices and noninvasive ventilators, are technologically complex and offer a considerable number of different modes of ventilation and setting options, the details of which are sometimes difficult to capture by the user. Therefore, better predicting and interpreting the actual performance of these ventilation devices in clinical application requires understanding their functioning principles and assessing their performance under well controlled bench test conditions with simulated patients. This concise review presents an updated perspective of the theoretical basis of intelligent continuous positive airway pressure and noninvasive ventilation devices, and of the tools available for assessing how these devices respond under specific ventilation phenotypes in patients requiring breathing support.

  16. Computed tomography dose and variability of airway dimension measurements: how low can we go?

    International Nuclear Information System (INIS)

    Jong, Pim A. de; Long, Frederick R.; Nakano, Yasutaka

    2006-01-01

    Quantitative CT shows promise as an outcome measure for cystic fibrosis (CF) lung disease in infancy, but must be accomplished at a dose as low as reasonably achievable. To determine the feasibility of ultra-low-dose CT for quantitative measurements of airway dimensions. Two juvenile pigs were anesthetized and their lungs scanned at 25 cm H 2 O face-mask pressure in apnoea using beam currents of 5, 10, 20, 40 and 100 mAs. The lumen diameters and wall thicknesses of matched airways (n=22) at each dose were measured by two observers using validated software. Measurement variability at each dose was compared to that at 100 mAs (reference dose) for large and small airways (lumen diameter <2.5 mm). Lowering CT dose (mAs) affected measurement variability for lumen diameter of small and large airways (P<0.001) and for wall thickness of small (P<0.001), but not large (P=0.63), airways. To obtain the same measurement variability at 5 mAs as at 100 mAs, four to six small airways or one to three large airways have to be measured and averaged. Quantitative airway measurements are feasible on images obtained at as low as 5 mAs, but more airways need to be measured to compensate for greater measurement variability. (orig.)

  17. A pilot study to examine the effect of the Tulip oropharyngeal airway on ventilation immediately after mask ventilation following the induction of anaesthesia.

    Science.gov (United States)

    Robinson, P N; Shaikh, A; Sabir, N M; Vaughan, D J A; Kynoch, M; Hasan, M

    2014-07-01

    The Tulip airway is an adult, disposable, single-sized oropharyngeal airway, that is connectable to an anaesthetic circuit. After a standardised induction of anaesthesia in 75 patients, the ease of insertion, intracuff pressure and intracuff volume were measured, as were the end-tidal carbon dioxide levels, airway pressures and tidal volumes over three breaths. Successful first-time insertion was achieved in 72 patients (96%, CI 88.8-99.2%) and after two attempts in 74 patients (99%, CI 92.8-100%). There was outright failure only in one patient. In 60 patients (80%, CI 72.2-90.4%), the Tulip airway provided a patent airway without additional manoeuvres, but in 14 patients, jaw thrust or head extension was necessary for airway patency. The main need for these adjuncts appeared to be an initial under-inflation of the cuff. These promising results are consistent with recent manikin studies using this device. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  18. Model predictive control approach for a CPAP-device

    Directory of Open Access Journals (Sweden)

    Scheel Mathias

    2017-09-01

    Full Text Available The obstructive sleep apnoea syndrome (OSAS is characterized by a collapse of the upper respiratory tract, resulting in a reduction of the blood oxygen- and an increase of the carbon dioxide (CO2 - concentration, which causes repeated sleep disruptions. The gold standard to treat the OSAS is the continuous positive airway pressure (CPAP therapy. The continuous pressure keeps the upper airway open and prevents the collapse of the upper respiratory tract and the pharynx. Most of the available CPAP-devices cannot maintain the pressure reference [1]. In this work a model predictive control approach is provided. This control approach has the possibility to include the patient’s breathing effort into the calculation of the control variable. Therefore a patient-individualized control strategy can be developed.

  19. The Use of bubble nasal CPAP in the management of IRDS -A Case ...

    African Journals Online (AJOL)

    owner

    2013-01-27

    Jan 27, 2013 ... low cost nasal continuous positive airway pressure de- livering system which ... with respiratory rate of 80 cycles/ min and had reduced air entry in the mid ... with features of respiratory distress from birth which progressively ...

  20. Efeitos da aplicação da EPAP (Expiratory Positive Airway Pressure sobre a tolerância ao esforço em pacientes portadores de insuficiência cardíaca

    Directory of Open Access Journals (Sweden)

    Claudia Thofehrn

    2013-04-01

    Full Text Available INTRODUÇÃO: Novas abordagens terapêuticas que objetivam melhorar a sensação de dispneia e fadiga em pacientes com insuficiência cardíaca, como a aplicação de pressão positiva expiratória nas vias aéreas (EPAP, podem ser aplicadas na tentativa de melhorar a capacidade funcional e a qualidade de vida. OBJETIVO: Avaliar os efeitos da utilização da EPAP ( Expiratory Positive Airway Pressure durante o esforço em indivíduos portadores de IC classe funcional II e III (NYHA. MÉTODOS: Dos 390 pacientes, foram selecionados 28 com FEVE < 40%. O Teste de Caminhada de seis minutos (TC6' foi realizado três vezes: o primeiro para a familiarização, um com a máscara e o outro sem a máscara de EPAP, sendo válido os dois últimos. A comparação entre os dados obtidos foi realizada por meio de teste t de Student pareado ou teste de Wilcoxon, conforme a normalidade dos dados. RESULTADOS: a percepção de esforço foi maior após a caminhada com a utilização da máscara quando comparado na ausência da máscara. Houve elevação significativa na saturação de oxigênio quando os pacientes estavam usando a máscara de EPAP. CONCLUSÃO: O uso da máscara de EPAP aumenta a percepção de esforço e o trabalho ventilatório, porém, não aumentou a distância percorrida no TC6, sendo sua aplicabilidade questionável em programas de reabilitação cardiovascular.