WorldWideScience

Sample records for continuous parameter monitoring

  1. Miniaturized pulse oximeter sensor for continuous vital parameter monitoring

    Science.gov (United States)

    Fiala, Jens; Reichelt, Stephan; Werber, Armin; Bingger, Philipp; Zappe, Hans; Förster, Katharina; Klemm, Rolf; Heilmann, Claudia; Beyersdorf, Friedhelm

    2007-07-01

    A miniaturized photoplethysmographic sensor system which utilizes the principle of pulse oximetry is presented. The sensor is designed to be implantable and will permit continuous monitoring of important human vital parameters such as arterial blood oxygen saturation as well as pulse rate and shape over a long-term period in vivo. The system employs light emitting diodes and a photo transistor embedded in a transparent elastic cu. which is directly wrapped around an arterial vessel. This paper highlights the specific challenges in design, instrumentation, and electronics associated with that sensor location. In vitro measurements were performed using an artificial circulation system which allows for regulation of the oxygen saturation and pulsatile pumping of whole blood through a section of a domestic pig's arterial vessel. We discuss our experimental results compared to reference CO-oximeter measurements and determine the empirical calibration curve. These results demonstrate the capabilities of the pulse oximeter implant for measurement of a wide range of oxygen saturation levels and pave the way for a continuous and mobile monitoring of high-risk cardiovascular patients.

  2. Bayesian parameter inference from continuously monitored quantum systems

    DEFF Research Database (Denmark)

    Gammelmark, Søren; Mølmer, Klaus

    2013-01-01

    We review the introduction of likelihood functions and Fisher information in classical estimation theory, and we show how they can be defined in a very similar manner within quantum measurement theory. We show that the stochastic master equations describing the dynamics of a quantum system subject...... to a definite set of measurements provides likelihood functions for unknown parameters in the system dynamics, and we show that the estimation error, given by the Fisher information, can be identified by stochastic master equation simulations. For large parameter spaces we describe and illustrate the efficient...

  3. Using continuous monitoring of physical parameters to better estimate phosphorus fluxes in a small agricultural catchment

    Science.gov (United States)

    Minaudo, Camille; Dupas, Rémi; Moatar, Florentina; Gascuel-Odoux, Chantal

    2016-04-01

    Phosphorus fluxes in streams are subjected to high temporal variations, questioning the relevance of the monitoring strategies (generally monthly sampling) chosen to assist EU Directives to capture phosphorus fluxes and their variations over time. The objective of this study was to estimate the annual and seasonal P flux uncertainties depending on several monitoring strategies, with varying sampling frequencies, but also taking into account simultaneous and continuous time-series of parameters such as turbidity, conductivity, groundwater level and precipitation. Total Phosphorus (TP), Soluble Reactive Phosphorus (SRP) and Total Suspended Solids (TSS) concentrations were surveyed at a fine temporal frequency between 2007 and 2015 at the outlet of a small agricultural catchment in Brittany (Naizin, 5 km2). Sampling occurred every 3 to 6 days between 2007 and 2012 and daily between 2013 and 2015. Additionally, 61 storms were intensively surveyed (1 sample every 30 minutes) since 2007. Besides, water discharge, turbidity, conductivity, groundwater level and precipitation were monitored on a sub-hourly basis. A strong temporal decoupling between SRP and particulate P (PP) was found (Dupas et al., 2015). The phosphorus-discharge relationships displayed two types of hysteretic patterns (clockwise and counterclockwise). For both cases, time-series of PP and SRP were estimated continuously for the whole period using an empirical model linking P concentrations with the hydrological and physic-chemical variables. The associated errors of the estimated P concentrations were also assessed. These « synthetic » PP and SRP time-series allowed us to discuss the most efficient monitoring strategies, first taking into account different sampling strategies based on Monte Carlo random simulations, and then adding the information from continuous data such as turbidity, conductivity and groundwater depth based on empirical modelling. Dupas et al., (2015, Distinct export dynamics for

  4. Evaluation of a Multi-Parameter Sensor for Automated, Continuous Cell Culture Monitoring in Bioreactors

    Science.gov (United States)

    Pappas, D.; Jeevarajan, A.; Anderson, M. M.

    2004-01-01

    offer automated, continuous monitoring of cell cultures with a temporal resolution of 1 minute, which is not attainable by sampling via handheld blood analyzer (i-STAT). Conclusion: The resulting bias and precision found in these cell culture-based studies is comparable to Paratrend sensor clinical results. Although the large error in p02 measurements (+/-18 mm Hg) may be acceptable for clinical applications, where Paratrend values are periodically adjusted to a BGA measurement, the O2 sensor in this bundle may not be reliable enough for the single-calibration requirement of sensors used in NASA's bioreactors. The pH and pC02 sensors in the bundle are reliable and stable over the measurement period, and can be used without recalibration to measure cell cultures in rn.jcrogravity biotechnology experiments. Future work will test additional Paratrend sensors to provide statistical assessment of sensor performance.

  5. Continuous auditing & continuous monitoring : Continuous value?

    NARCIS (Netherlands)

    van Hillo, Rutger; Weigand, Hans; Espana, S; Ralyte, J; Souveyet, C

    2016-01-01

    Advancements in information technology, new laws and regulations and rapidly changing business conditions have led to a need for more timely and ongoing assurance with effectively working controls. Continuous Auditing (CA) and Continuous Monitoring (CM) technologies have made this possible by obtain

  6. Continuous auditing & continuous monitoring : Continuous value?

    NARCIS (Netherlands)

    van Hillo, Rutger; Weigand, Hans; Espana, S; Ralyte, J; Souveyet, C

    2016-01-01

    Advancements in information technology, new laws and regulations and rapidly changing business conditions have led to a need for more timely and ongoing assurance with effectively working controls. Continuous Auditing (CA) and Continuous Monitoring (CM) technologies have made this possible by obtain

  7. Continuous auditing & continuous monitoring : Continuous value?

    NARCIS (Netherlands)

    van Hillo, Rutger; Weigand, Hans; Espana, S; Ralyte, J; Souveyet, C

    2016-01-01

    Advancements in information technology, new laws and regulations and rapidly changing business conditions have led to a need for more timely and ongoing assurance with effectively working controls. Continuous Auditing (CA) and Continuous Monitoring (CM) technologies have made this possible by

  8. Continuous glucose monitoring, oral glucose tolerance, and insulin - glucose parameters in adolescents with simple obesity.

    Science.gov (United States)

    El Awwa, A; Soliman, A; Al-Ali, M; Yassin, M; De Sanctis, V

    2012-09-01

    In obese adolescents pancreatic beta-cells may not be able to cope with insulin resistance leading to hyperglycemia and type2 diabetes (T2DM To assess oral glucose tolerance, 72-h continuous blood glucose concentrations (CGM) and calculate homeostatic model assessment (HOMA), and the quantitative insulin sensitivity check index (QUICKI) in 13 adolescents with simple obesity (BMI SDS=4 ± 1.06). OGTT performed in 13 obese adolescents (13.47 ± 3 years) revealed 3 cases (23%) with impaired fasting glucose (IFG: fasting glucose >5.6 mmol/L), 4 cases (30%) with impaired glucose tolerance (IGT: 2h blood glucose >7.8 7.8 and 11.1 mmol/L (diabetes) in one case (7.6%). Five cases had a minimum BG recorded of 2.6 and QUICKI values <0.35 denoting insulin resistance. Beta cell mass percent (B %) = 200 ± 94.8% and insulin sensitivity values (IS)=50.4 ± 45.5% denoted insulin resistance with hyper-insulinaemia and preserved beta cell mass. In obese adolescents, CGMS is superior to OGTT and HbA1C in detecting glycemic abnormalities, which appears to be secondary to insulin resistance.

  9. 40 CFR 63.4168 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Science.gov (United States)

    2010-07-01

    ... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... monitor pressure drop across the zeolite wheel or rotary carbon bed. The pressure monitoring device must... pressure sensor(s) in or as close to a position that provides a representative measurement of the pressure...

  10. Nocturnal continuous glucose monitoring

    DEFF Research Database (Denmark)

    Bay, Christiane; Kristensen, Peter Lommer; Pedersen-Bjergaard, Ulrik;

    2013-01-01

    Abstract Background: A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe...

  11. Continuous monitoring of biophysical Eucalyptus sp. parameters using interferometric synthetic aperture radar data in P and X bands

    Science.gov (United States)

    Gama, Fábio Furlan; dos Santos, João Roberto; Mura, José Claudio

    2016-04-01

    This work aims to verify the applicability of models obtained using interferometric synthetic aperture radar (SAR) data for estimation of biophysical Eucalyptus saligna parameters [diameter of breast height (DBH), total height and volume], as a method of continuous forest inventory. In order to obtain different digital elevation models, and the interferometric height (Hint) to retrieve the tree heights, SAR surveying was carried out by an airborne interferometric SAR in two frequencies X and P bands. The study area, located in the Brazilian southeast region (S 22°53‧22″/W 45°26‧16″ and S 22°53‧22″/W 45°26‧16″), comprises 128.64 hectares of Eucalyptus saligna stands. The methodological procedures encompassed: forest inventory, topographic surveying, radar mapping, radar processing, and multivariable regression techniques to build Eucalyptus volume, DBH, and height models. The statistical regression pointed out Hint and interferometric coherence as the most important variables for the total height and DBH estimation; for the volume model, however, only the Hint variable was selected. The performance of the biophysical models from the second campaign, two years later (2006), were consistent and its results are very promising for updating annual inventories needed for managing Eucalyptus plantations.

  12. 40 CFR 63.3968 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Science.gov (United States)

    2010-07-01

    .... Monitoring failures that are caused in part by poor maintenance or careless operation are not malfunctions... install a device to monitor pressure drop across the zeolite wheel or rotary carbon bed. The pressure... signal simulations or via relative accuracy testing. (v) Conduct an accuracy audit every quarter and...

  13. 40 CFR 63.4568 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Science.gov (United States)

    2010-07-01

    ... caused in part by poor maintenance or careless operation are not malfunctions. Any period for which the... install a device to monitor pressure drop across the zeolite wheel or rotary carbon bed. The pressure... simulations or via relative accuracy testing. (v) Conduct an accuracy audit every quarter and after every...

  14. Improved Control Of cheese Manufacture Through continuous Vat Monitoring Of Coagulation Parameters Using The Hot Wire Method

    OpenAIRE

    LeFevre, Michael John

    1995-01-01

    The hot wire method, with pH and temperature sensors, was evaluated to determine its usefulness and application for cheese production automation. Coagulation of milk substrate was measured with the hot wire instrument and by four other methods: Formagraph, Brookfield®, vixcometer, Omnispec™ bioactivity monitor, and Sommer and Matsen rolling bottle method. The hot wire, using the time at maximum slope, detected coagulation before methods that measure resistance to shear, and after methods that...

  15. VERONA V6.22 – An enhanced reactor analysis tool applied for continuous core parameter monitoring at Paks NPP

    Energy Technology Data Exchange (ETDEWEB)

    Végh, J., E-mail: janos.vegh@ec.europa.eu [Institute for Energy and Transport of the Joint Research Centre of the European Commission, Postbus 2, NL-1755 ZG Petten (Netherlands); Pós, I., E-mail: pos@npp.hu [Paks Nuclear Power Plant Ltd., H-7031 Paks, P.O. Box 71 (Hungary); Horváth, Cs., E-mail: csaba.horvath@energia.mta.hu [Centre for Energy Research, Hungarian Academy of Sciences, H-1525 Budapest 114, P.O. Box 49 (Hungary); Kálya, Z., E-mail: kalyaz@npp.hu [Paks Nuclear Power Plant Ltd., H-7031 Paks, P.O. Box 71 (Hungary); Parkó, T., E-mail: parkot@npp.hu [Paks Nuclear Power Plant Ltd., H-7031 Paks, P.O. Box 71 (Hungary); Ignits, M., E-mail: ignits@npp.hu [Paks Nuclear Power Plant Ltd., H-7031 Paks, P.O. Box 71 (Hungary)

    2015-10-15

    Between 2003 and 2007 the Hungarian Paks NPP performed a large modernization project to upgrade its VERONA core monitoring system. The modernization work resulted in a state-of-the-art system that was able to support the reactor thermal power increase to 108% by more accurate and more frequent core analysis. Details of the new system are given in Végh et al. (2008), the most important improvements were as follows: complete replacement of the hardware and the local area network; application of a new operating system and porting a large fraction of the original application software to the new environment; implementation of a new human-system interface; and last but not least, introduction of new reactor physics calculations. Basic novelty of the modernized core analysis was the introduction of an on-line core-follow module based on the standard Paks NPP core design code HELIOS/C-PORCA. New calculations also provided much finer spatial resolution, both in terms of axial node numbers and within the fuel assemblies. The new system was able to calculate the fuel applied during the first phase of power increase accurately, but it was not tailored to determine the effects of burnable absorbers as gadolinium. However, in the second phase of the power increase process the application of fuel assemblies containing three fuel rods with gadolinium content was intended (in order to optimize fuel economy), therefore off-line and on-line VERONA reactor physics models had to be further modified, to be able to handle the new fuel according to the accuracy requirements. In the present paper first a brief overview of the system version (V6.0) commissioned after the first modernization step is outlined; then details of the modified off-line and on-line reactor physics calculations are described. Validation results for new modules are treated extensively, in order to illustrate the extent and complexity of the V&V procedure associated with the development and licensing of the new

  16. Voltage stability, bifurcation parameters and continuation methods

    Energy Technology Data Exchange (ETDEWEB)

    Alvarado, F.L. [Wisconsin Univ., Madison, WI (United States)

    1994-12-31

    This paper considers the importance of the choice of bifurcation parameter in the determination of the voltage stability limit and the maximum power load ability of a system. When the bifurcation parameter is power demand, the two limits are equivalent. However, when other types of load models and bifurcation parameters are considered, the two concepts differ. The continuation method is considered as a method for determination of voltage stability margins. Three variants of the continuation method are described: the continuation parameter is the bifurcation parameter the continuation parameter is initially the bifurcation parameter, but is free to change, and the continuation parameter is a new `arc length` parameter. Implementations of voltage stability software using continuation methods are described. (author) 23 refs., 9 figs.

  17. Continuous glucose monitoring in acute coronary syndrome.

    Science.gov (United States)

    Rodríguez-Quintanilla, Karina Alejandra; Lavalle-González, Fernando Javier; Mancillas-Adame, Leonardo Guadalupe; Zapata-Garrido, Alfonso Javier; Villarreal-Pérez, Jesús Zacarías; Tamez-Pérez, Héctor Eloy

    2013-01-01

    Diabetes mellitus is an independent risk factor for cardiovascular disease. To compare the efficacy of devices for continuous glucose monitoring and capillary glucose monitoring in hospitalized patients with acute coronary syndrome using the following parameters: time to achieve normoglycemia, period of time in normoglycemia, and episodes of hypoglycemia. We performed a pilot, non-randomized, unblinded clinical trial that included 16 patients with acute coronary artery syndrome, a capillary or venous blood glucose ≥ 140 mg/dl, and treatment with a continuous infusion of fast acting human insulin. These patients were randomized into 2 groups: a conventional group, in which capillary measurement and recording as well as insulin adjustment were made every 4h, and an intervention group, in which measurement and recording as well as insulin adjustment were made every hour with a subcutaneous continuous monitoring system. Student's t-test was applied for mean differences and the X(2) test for qualitative variables. We observed a statistically significant difference in the mean time for achieving normoglycemia, favoring the conventional group with a P = 0.02. Continuous monitoring systems are as useful as capillary monitoring for achieving normoglycemia. Copyright © 2012 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  18. Wide area continuous offender monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hoshen, J. [Lucent Technologies (United States); Drake, G. [New Mexico Dept. of Corrections, Santa Fe, NM (United States); Spencer, D. [Sandia National Labs., Albuquerque, NM (United States)

    1996-11-01

    The corrections system in the U.S. is supervising over five million offenders. This number is rising fast and so are the direct and indirect costs to society. To improve supervision and reduce the cost of parole and probation, first generation home arrest systems were introduced in 1987. While these systems proved to be helpful to the corrections system, their scope is rather limited because they only cover an offender at a single location and provide only a partial time coverage. To correct the limitations of first-generation systems, second-generation wide area continuous electronic offender monitoring systems, designed to monitor the offender at all times and locations, are now on the drawing board. These systems use radio frequency location technology to track the position of offenders. The challenge for this technology is the development of reliable personal locator devices that are small, lightweight, with long operational battery life, and indoors/outdoors accuracy of 100 meters or less. At the center of a second-generation system is a database that specifies the offender`s home, workplace, commute, and time the offender should be found in each. The database could also define areas from which the offender is excluded. To test compliance, the system would compare the observed coordinates of the offender with the stored location for a given time interval. Database logfiles will also enable law enforcement to determine if a monitored offender was present at a crime scene and thus include or exclude the offender as a potential suspect.

  19. Parameter Estimation in Continuous Time Domain

    Directory of Open Access Journals (Sweden)

    Gabriela M. ATANASIU

    2016-12-01

    Full Text Available This paper will aim to presents the applications of a continuous-time parameter estimation method for estimating structural parameters of a real bridge structure. For the purpose of illustrating this method two case studies of a bridge pile located in a highly seismic risk area are considered, for which the structural parameters for the mass, damping and stiffness are estimated. The estimation process is followed by the validation of the analytical results and comparison with them to the measurement data. Further benefits and applications for the continuous-time parameter estimation method in civil engineering are presented in the final part of this paper.

  20. Mercury Continuous Emmission Monitor Calibration

    Energy Technology Data Exchange (ETDEWEB)

    John Schabron; Eric Kalberer; Ryan Boysen; William Schuster; Joseph Rovani

    2009-03-12

    Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma

  1. Bayesian parameter estimation by continuous homodyne detection

    DEFF Research Database (Denmark)

    Kiilerich, Alexander Holm; Molmer, Klaus

    2016-01-01

    and we show that the ensuing transient evolution is more sensitive to system parameters than the steady state of the system. The parameter sensitivity can be quantified by the Fisher information, and we investigate numerically and analytically how the temporal noise correlations in the measurement signal......We simulate the process of continuous homodyne detection of the radiative emission from a quantum system, and we investigate how a Bayesian analysis can be employed to determine unknown parameters that govern the system evolution. Measurement backaction quenches the system dynamics at all times...

  2. Bayesian parameter estimation by continuous homodyne detection

    Science.gov (United States)

    Kiilerich, Alexander Holm; Mølmer, Klaus

    2016-09-01

    We simulate the process of continuous homodyne detection of the radiative emission from a quantum system, and we investigate how a Bayesian analysis can be employed to determine unknown parameters that govern the system evolution. Measurement backaction quenches the system dynamics at all times and we show that the ensuing transient evolution is more sensitive to system parameters than the steady state of the system. The parameter sensitivity can be quantified by the Fisher information, and we investigate numerically and analytically how the temporal noise correlations in the measurement signal contribute to the ultimate sensitivity limit of homodyne detection.

  3. Continuous Delivery and Quality Monitoring

    CERN Document Server

    CERN. Geneva

    2016-01-01

    After introducing Continuous Delivery, I will switch the topic and try to answer the question how much should we invest in quality and how to do it efficiently. My observations reveal that software quality is often considered as the slo...

  4. Simple chloride sensors for continuous groundwater monitoring

    DEFF Research Database (Denmark)

    Thorn, Paul; Mortensen, John

    2012-01-01

    The development of chloride sensors which can be used for continuous, on-line monitoring of groundwater could be very valuable in the management of our coastal water resources. However, sensor stability, drift, and durability all need to be addressed in order for the sensors to be used...... in continuous application. This study looks at the development of a simple, inexpensive chloride electrode, and evaluates its performance under continuous use, both in the laboratory and in a field test in a monitoring well. The results from the study showed a consistent response to changing chloride...... sensor remained responsive even at low chloride concentrations, where the conductivity electrode was no longer responding to changing chloride levels. With the results, it is believed that the simple chloride sensor could be used for continuous monitoring of groundwater quality....

  5. Application on drilling parameter monitor in drilling engineering monitoring

    Institute of Scientific and Technical Information of China (English)

    Shu DIAO; Zhenbao LING; Wenjing LIANG

    2008-01-01

    The drilling parameter monitor is an important tool in drilling engineering applied to monitoring drilling process, carrying out scientific analysis and decision-making. Based on discussing the present development situation of the domestic and foreign drilling machine parameter monitors, the metering scheme for vehicle-loaded drilling parameter monitor was designed. By using detection system for MSP430 single-chip microcomputer (SCM) in combination with peripheral circuit such as sensors, the drilling-rig control system was obtained to detect, and for every parameter in real-time display in order to keep operating the drilling rig status. The experiment shows that the drilling parameter monitor reaches design requirements and can be applied to drilling engineering monitoring, which has characters such as simple structure, high credibility and low cost.

  6. Lagoon Monitoring and Condition Parameters

    OpenAIRE

    Harrison, John; Smith, Dallen

    2004-01-01

    Lagoons combine storage and tr eatment functions and thus are more sensitive to management inputs than are solid or slurry facilities. The est ablishment and maintenance of desirable microbiological populations in lagoons requires more specific procedures in the way lagoons are loaded and monitored.

  7. Continuous Glucose Monitoring Systems: A Review

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Vashist

    2013-10-01

    Full Text Available There have been continuous advances in the field of glucose monitoring during the last four decades, which have led to the development of highly evolved blood glucose meters, non-invasive glucose monitoring (NGM devices and continuous glucose monitoring systems (CGMS. Glucose monitoring is an integral part of diabetes management, and the maintenance of physiological blood glucose concentration is the only way for a diabetic to avoid life-threatening diabetic complications. CGMS have led to tremendous improvements in diabetic management, as shown by the significant lowering of glycated hemoglobin (HbA1c in adults with type I diabetes. Most of the CGMS have been minimally-invasive, although the more recent ones are based on NGM techniques. This manuscript reviews the advances in CGMS for diabetes management along with the future prospects and the challenges involved.

  8. Continuous respirable mine dust monitor development

    Energy Technology Data Exchange (ETDEWEB)

    Cantrell, B.K.; Williams, K.L.; Stein, S.W. [and others

    1996-12-31

    In June 1992, the Mine Safety and Health Administration (MSHA) published the Report of the Coal Mine Respirable Dust Task Group, Review of the Program to Control Respirable Coal Mine Dust in the United States. As one of its recommendations, the report called for the accelerated development of two mine dust monitors: (1) a fixed-site monitor capable of providing continuous information on dust levels to the miner, mine operator, and to MSHA, if necessary, and (2) a personal sampling device capable of providing both a short-term personal exposure measurement as well as a full-shift measurement. In response to this recommendation, the U.S. Bureau of Mines initiated the development of a fixed-site machine-mounted continuous respirable dust monitor. The technology chosen for monitor development is the Rupprecht and Patashnick Co., Inc. tapered element oscillating microbalance. Laboratory and in-mine tests have indicated that, with modification, this sensor can meet the humidity and vibration requirements for underground coal mine use. The U.S. Department of Energy Pittsburgh Research Center (DOE-PRC) is continuing that effort by developing prototypes of a continuous dust monitor based on this technology. These prototypes are being evaluated in underground coal mines as they become available. This effort, conducted as a joint venture with MSHA, is nearing completion with every promise of success.

  9. Limitations of Continuous Glucose Monitor Usage.

    Science.gov (United States)

    Anhalt, Henry

    2016-03-01

    Much progress has been made in diabetes treatments since the first dose of insulin was administered in 1921. However, a truly transformational moment in diabetes care occurred when urine testing gave way to capillary blood home glucose monitoring. As improvements were made to these devices, continuous glucose monitoring (CGM) was introduced. The advantages of experiential learnings gleaned from seeing continuous real-time data have been borne out in numerous peer-reviewed journals. Limitations to use of CGM include patient's level of numeracy and literacy, development of alarm fatigue, interfering substances leading to erroneous readings, high rates of discontinuation, and poor reimbursement.

  10. Continuous EEG Monitoring in Aneurysmal Subarachnoid Hemorrhage

    DEFF Research Database (Denmark)

    Kondziella, Daniel; Friberg, Christian Kærsmose; Wellwood, Ian

    2015-01-01

    BACKGROUND: Continuous EEG (cEEG) may allow monitoring of patients with aneurysmal subarachnoid hemorrhage (SAH) for delayed cerebral ischemia (DCI) and seizures, including non-convulsive seizures (NCSz), and non-convulsive status epilepticus (NCSE). We aimed to evaluate: (a) the diagnostic...

  11. Continuous blood gas monitoring in femoral arteries

    Science.gov (United States)

    Schlain, Les A.; Spar, Steven M.; Dellinger, Bart

    1995-05-01

    Continuous intra-arterial blood gas monitoring is a potentially valuable tool in the surgical and intensive care arenas. Patient oxygenation and acid base status can change rapidly and without warning. The ability to monitor pHa, PaCO2 and PaO2 in arterial blood will be a major medical advance for the anesthesiologist and intensivist. Intra-arterial blood gas sensors are typically placed in radial arteries. In certain patient populations accurate monitoring is not possible in radial arteries due to arterial environmental factors such as hypotension, vasoconstriction and atherosclerotic disease. These same factors can make radial cannulation difficult resulting in traumatic catheter insertion, thereby further compromising flow conditions. In situations where radial artery flow is expected to be compromised, selecting a large vessel for sensor placement is desirable. We report an initial feasibility study of our blood gas monitoring system using the femoral artery as the sensing site. Clinical results are presented as well as potential advantages and disadvantages associated with monitoring in the femoral artery.

  12. Method for Continuous Monitoring of Electrospray Ion Formation

    Science.gov (United States)

    Metzler, Guille; Crathern, Susan; Bachmann, Lorin; Fernández-Metzler, Carmen; King, Richard

    2017-10-01

    A method for continuously monitoring the performance of electrospray ionization without the addition of hardware or chemistry to the system is demonstrated. In the method, which we refer to as SprayDx, cluster ions with solvent vapor natively formed by electrospray are followed throughout the collection of liquid chromatography-selected reaction monitoring data. The cluster ion extracted ion chromatograms report on the consistency of the ion formation and detection system. The data collected by the SprayDx method resemble the data collected for postcolumn infusion of analyte. The response of the cluster ions monitored reports on changes in the physical parameters of the ion source such as voltage and gas flow. SprayDx is also observed to report on ion suppression in a fashion very similar to a postcolumn infusion of analyte. We anticipate the method finding utility as a continuous readout on the performance of electrospray and other atmospheric pressure ionization processes. [Figure not available: see fulltext.

  13. Continuous Glucose Monitoring and Trend Accuracy

    Science.gov (United States)

    Gottlieb, Rebecca; Le Compte, Aaron; Chase, J. Geoffrey

    2014-01-01

    Continuous glucose monitoring (CGM) devices are being increasingly used to monitor glycemia in people with diabetes. One advantage with CGM is the ability to monitor the trend of sensor glucose (SG) over time. However, there are few metrics available for assessing the trend accuracy of CGM devices. The aim of this study was to develop an easy to interpret tool for assessing trend accuracy of CGM data. SG data from CGM were compared to hourly blood glucose (BG) measurements and trend accuracy was quantified using the dot product. Trend accuracy results are displayed on the Trend Compass, which depicts trend accuracy as a function of BG. A trend performance table and Trend Index (TI) metric are also proposed. The Trend Compass was tested using simulated CGM data with varying levels of error and variability, as well as real clinical CGM data. The results show that the Trend Compass is an effective tool for differentiating good trend accuracy from poor trend accuracy, independent of glycemic variability. Furthermore, the real clinical data show that the Trend Compass assesses trend accuracy independent of point bias error. Finally, the importance of assessing trend accuracy as a function of BG level is highlighted in a case example of low and falling BG data, with corresponding rising SG data. This study developed a simple to use tool for quantifying trend accuracy. The resulting trend accuracy is easily interpreted on the Trend Compass plot, and if required, performance table and TI metric. PMID:24876437

  14. Wide-area continuous offender monitoring

    Science.gov (United States)

    Hoshen, Joseph; Drake, George; Spencer, Debra D.

    1997-02-01

    The corrections system in the U.S. is supervising over five million offenders. This number is rising fast and so are the direct and indirect costs to society. To improve supervision and reduce the cost of parole and probation, first generation home arrest systems were introduced in 1987. While these systems proved to be helpful to the corrections system, their scope is rather limited because they only cover an offender at a single location and provide only a partial time coverage. To correct the limitations of first- generation systems, second-generation wide area continuous electronic offender monitoring systems, designed to monitor the offender at all times and locations, are now on the drawing board. These systems use radio frequency location technology to track the position of offenders. The challenge for this technology is the development of reliable personal locator devices that are small, lightweight, with long operational battery life, and indoors/outdoors accuracy of 100 meters or less. At the center of a second-generation system is a database that specifies the offender's home, workplace, commute, and time the offender should be found in each. The database could also define areas from which the offender is excluded. To test compliance, the system would compare the observed coordinates of the offender with the stored location for a given time interval. Database logfiles will also enable law enforcement to determine if a monitored offender was present at a crime scene and thus include or exclude the offender as a potential suspect.

  15. Continuous glucose monitoring: current clinical use.

    Science.gov (United States)

    Kim, Hun-Sung; Shin, Jeong-Ah; Chang, Jin-Sun; Cho, Jae-Hyoung; Son, Ho-Young; Yoon, Kun-Ho

    2012-12-01

    Four kinds of subcutaneous continuous glucose monitoring (CGM) machines have been currently introduced in clinical practice. These machines exhibit real-time glucose on the monitor every 5 minutes and have alarms to indicate hypoglycaemia and hyperglycaemia. However, thus far, there is no clear consensus about the clinical indications for CGM in actual clinical practice. CGM should be an ideal and powerful tool for monitoring glucose variability. Glycaemic variability has become a major concern over the years with growing evidence on its detrimental impact with respect to the risk of diabetic complications. Although the HbA1c level is ubiquitously measures in clinical practice, this level does not adequately represent glycaemic variability. Currently available evidence indicates that CGM aids in lowering the HbA1c level without increasing the incidence of severe hypoglycaemic episodes in patients with type 1 diabetes. Thus far, CGM has not been indicated for preventing severe hypoglycaemia or for treating type 2 diabetes because sufficient supporting evidence has not been obtained. Promising results have been obtained for the use of CGM for pregnant women with diabetes and for patients with hospital hyperglycaemia. Predictions regarding the feasibility of the closed-loop system have proven to be optimistic. CGM-integrated communication systems using information technology such as smart phone help controlling blood glucose more easily and effectively.

  16. Continuous Outlier Monitoring on Uncertain Data Streams

    Institute of Scientific and Technical Information of China (English)

    曹科研; 王国仁; 韩东红; 丁国辉; 王爱侠; 石凌旭

    2014-01-01

    Outlier detection on data streams is an important task in data mining. The challenges become even larger when considering uncertain data. This paper studies the problem of outlier detection on uncertain data streams. We propose Continuous Uncertain Outlier Detection (CUOD), which can quickly determine the nature of the uncertain elements by pruning to improve the efficiency. Furthermore, we propose a pruning approach - Probability Pruning for Continuous Uncertain Outlier Detection (PCUOD) to reduce the detection cost. It is an estimated outlier probability method which can effectively reduce the amount of calculations. The cost of PCUOD incremental algorithm can satisfy the demand of uncertain data streams. Finally, a new method for parameter variable queries to CUOD is proposed, enabling the concurrent execution of different queries. To the best of our knowledge, this paper is the first work to perform outlier detection on uncertain data streams which can handle parameter variable queries simultaneously. Our methods are verified using both real data and synthetic data. The results show that they are able to reduce the required storage and running time.

  17. Current Trends in Continuous Glucose Monitoring.

    Science.gov (United States)

    Lodwig, Volker; Kulzer, Bernhard; Schnell, Oliver; Heinemann, Lutz

    2014-03-01

    The market introduction of systems for continuous glucose monitoring (CGM) some 15 years ago did not immediately revolutionize the treatment of diabetes; however, for a given group of patients, it would almost be inconceivable nowadays to imagine life without CGM. One day the development of insulin pumps together with CGM could culminate in an artificial pancreas system. The performance of the glucose sensors used for glucose measurement in the interstitial fluid in the subcutaneous tissue and the algorithms employed to analyze these data have improved so much over the past decade that current CGM systems by far outperform those of the first generations. This commentary discusses a number of aspects about what we have learned since CGM systems entered the market and what current trends exist in their usage. Some of these are major hurdles facing a more widespread usage of CGM.

  18. Smart Vest: wearable multi-parameter remote physiological monitoring system.

    Science.gov (United States)

    Pandian, P S; Mohanavelu, K; Safeer, K P; Kotresh, T M; Shakunthala, D T; Gopal, Parvati; Padaki, V C

    2008-05-01

    The wearable physiological monitoring system is a washable shirt, which uses an array of sensors connected to a central processing unit with firmware for continuously monitoring physiological signals. The data collected can be correlated to produce an overall picture of the wearer's health. In this paper, we discuss the wearable physiological monitoring system called 'Smart Vest'. The Smart Vest consists of a comfortable to wear vest with sensors integrated for monitoring physiological parameters, wearable data acquisition and processing hardware and remote monitoring station. The wearable data acquisition system is designed using microcontroller and interfaced with wireless communication and global positioning system (GPS) modules. The physiological signals monitored are electrocardiogram (ECG), photoplethysmogram (PPG), body temperature, blood pressure, galvanic skin response (GSR) and heart rate. The acquired physiological signals are sampled at 250samples/s, digitized at 12-bit resolution and transmitted wireless to a remote physiological monitoring station along with the geo-location of the wearer. The paper describes a prototype Smart Vest system used for remote monitoring of physiological parameters and the clinical validation of the data are also presented.

  19. Toward a Continuous Intravascular Glucose Monitoring System

    Directory of Open Access Journals (Sweden)

    Pedro Irazoqui

    2010-12-01

    Full Text Available Proof-of-concept studies that display the potential of using a glucose-sensitive hydrogel as a continuous glucose sensor are presented. The swelling ratio, porosity, and diffusivity of the hydrogel increased with glucose concentration. In glucose solutions of 50, 100, 200, and 300 mg/dL, the hydrogel swelling ratios were 4.9, 12.3, 15.9, and 21.7, respectively, and the swelling was reversible. The impedance across the hydrogel depended solely on the thickness and had an average increase of 47 W/mm. The hydrogels exposed to a hyperglycemic solution were more porous than the hydrogels exposed to a normal glycemic solution. The diffusivity of 390 Da MW fluorescein isothiocyanate in hydrogels exposed to normal and hyperglycemic solutions was examined using fluorescence recovery after photobleaching and was found to be 9.3 × 10−14 and 41.4 × 10−14 m2/s, respectively, compared to 6.2 × 10−10 m2/s in glucose solution. There was no significant difference between the permeability of hydrogels in normal and hyperglycemic glucose solutions with averages being 5.26 × 10−17 m2 and 5.80 × 10−17 m2, respectively, which resembles 2–4% agarose gels. A prototype design is presented for continuous intravascular glucose monitoring by attaching a glucose sensor to an FDA-approved stent.

  20. Coastal environment: historical and continuous monitoring

    Science.gov (United States)

    Ivaldi, Roberta; Surace, Luciano

    2010-05-01

    The monitoring is a tool providing essential data to study the process dynamic. The formation and transformation of coastal environment involve physical, chemical, geological and biological processes. The knowledge of the littoral systems and marine seafloor therefore requires a multidisciplinary approach. Since the phenomena observation occurs in a short period of time it requires the use of high quality data acquired with high accuracy and suitable processing procedures. This knowledge considerable increased during the past 50 years closely following significant progress in the methods of investigation at sea and laboratory. In addition seafloor exploration is deeply rooted in History. A sector actually subject to control results the coastal zone for its position as transition component between continental and marine environments with closely connected natural and human actions. Certainly these activities are important in the time to develop the technologies suited for the knowledge and to increase different protection, prevention, intervention and management tools. In this context the Istituto Idrografico della Marina (Hydrographic Institute of Italian Navy - I.I.M.) is a precursor because since its foundation (in 1872) it contributed to the monitoring activities related to charting and navigation, including hydrologic surveying, seafloor measurements and in consequence the landward limit, the shoreline. The coastal area is certainly the most changeable sector either natural or socio-economic causes. This is the most dynamic environment, subject both to marine (waves and currents) and continental (river and ice) actions, and continuously changing the intended use for the increase of industrial, commercial, recreation and the need for new structures to support. The coast has more recently taken on a growing value determined by some processes, including erosion and retreat are evidence of a transformation of which, however, undermine the system and impoverishing

  1. Identification of parameters of discrete-continuous models

    Energy Technology Data Exchange (ETDEWEB)

    Cekus, Dawid, E-mail: cekus@imipkm.pcz.pl; Warys, Pawel, E-mail: warys@imipkm.pcz.pl [Institute of Mechanics and Machine Design Foundations, Czestochowa University of Technology, Dabrowskiego 73, 42-201 Czestochowa (Poland)

    2015-03-10

    In the paper, the parameters of a discrete-continuous model have been identified on the basis of experimental investigations and formulation of optimization problem. The discrete-continuous model represents a cantilever stepped Timoshenko beam. The mathematical model has been formulated and solved according to the Lagrange multiplier formalism. Optimization has been based on the genetic algorithm. The presented proceeding’s stages make the identification of any parameters of discrete-continuous systems possible.

  2. Continuous monitoring of plant water potential.

    Science.gov (United States)

    Schaefer, N L; Trickett, E S; Ceresa, A; Barrs, H D

    1986-05-01

    Plant water potential was monitored continuously with a Wescor HR-33T dewpoint hygrometer in conjunction with a L51 chamber. This commercial instrument was modified by replacing the AC-DC mains power converter with one stabilized by zener diode controlled transistors. The thermocouple sensor and electrical lead needed to be thermally insulated to prevent spurious signals. For rapid response and faithful tracking a low resistance for water vapor movement between leaf and sensor had to be provided. This could be effected by removing the epidermis either by peeling or abrasion with fine carborundum cloth. A variety of rapid plant water potential responses to external stimuli could be followed in a range of crop plants (sunflower (Helianthus annuus L., var. Hysun 30); safflower (Carthamus tinctorious L., var. Gila); soybean (Glycine max L., var. Clark); wheat (Triticum aestivum L., var. Egret). These included light dark changes, leaf excision, applied pressure to or anaerobiosis of the root system. Water uptake by the plant (safflower, soybean) mirrored that for water potential changes including times when plant water status (soybean) was undergoing cyclical changes.

  3. US EPA Base Study Standard Operating Procedure for Continuous Monitoring of Outdoor Air

    Science.gov (United States)

    The procedure described is intended for monitoring continuously and simultaneously outdoor air quality parameters that are most commonly associated with indoor air quality: the concentrations of carbon dioxide (CO2) and carbon monoxide (CO), temperature, nd relative humidity (RH).

  4. Long term continuous radon monitoring in a seismically active area

    CERN Document Server

    Piersanti, A; Galli, G

    2015-01-01

    We present the results of a long term, continuous radon monitoring experiment started in April 2010 in a seismically active area, affected during the 2010-2013 data acquisition time window by an intense micro seismic activity and by several small seismic events. We employed both correlation and cross-correlation analyses in order to investigate possible relationship existing between the collected radon data, seismic events and meteorological parameters. Our results do not support the feasibility of a robust one-to-one association between the small magnitude earthquakes characterizing the local seismic activity and single radon measurement anomalies, but evidence significant correlation patterns between the spatio-temporal variations of seismic moment release and soil radon emanations, the latter being anyway dominantly modulated by meteorological parameters variations.

  5. The Pollino 2012 seismic sequence: clues from continuous radon monitoring

    Science.gov (United States)

    Piersanti, Antonio; Cannelli, Valentina; Galli, Gianfranco

    2016-09-01

    The 2012 Pollino (Calabria, Italy) seismic sequence, culminating in the Mw 5.2 earthquake of 25 October 2012, is investigated, exploiting data collected during a long-term continuous radon monitoring experiment performed in the epicentral area from late 2011 to the end of 2014. We analyse data collected both using a phenomenological approach based on quantitative evidence and a purely numerical analysis including the following: (i) correlation and cross-correlation investigations; (ii) an original approach aimed at limiting the impact of meteorological parameters variations on the interpretation of measured radon levels; (iii) a change point analysis; (iv) the implementation of an original detection algorithm aimed at highlighting the connections between radon emission variations and major seismic events occurrence. Results from both approaches suggest that radon monitoring stations can be subject to massive site effects, especially regarding rainfall, making data interpretation harder. The availability of long-term continuous measurements is crucial to precisely assess those effects. Nevertheless, statistical analysis shows a viable approach for quantitatively relating radon emanation variations to seismic energy release. Although much work is still needed to make radon time series analysis a robust complement to traditional seismological tools, this work has identified a characteristic variation in radon exhalation during the preparation process of large earthquakes.

  6. Groundwater pollution: are we monitoring appropriate parameters?

    CSIR Research Space (South Africa)

    Tredoux, G

    2004-01-01

    Full Text Available . In the literature, divergent approaches have identified various sets of pollutants and pollution indicators. This paper discusses international and local trends in groundwater monitoring for baseline studies and on-going pollution detection monitoring for a variety...

  7. Ultrafiltrate sampling device for continuous monitoring

    NARCIS (Netherlands)

    Moscone, D; Venema, K; Korf, J

    1996-01-01

    A light, portable sampling device for ?he continuous collection and storage of subcutaneous fluid is described. It consists of a hollow-fibre probe for ultrafiltration, a long tube for sample storage and a vacuum tube as driving force. introduction of a restriction in the flow path allows a constant

  8. Continuous damage parameter calculation under thermo-mechanical random loading

    OpenAIRE

    Marko Nagode

    2014-01-01

    The paper presents a method on how the mean stress effect on fatigue damage can be taken into account under an arbitrary low cycle thermo-mechanical loading. From known stress, elastoplastic strain and temperature histories the cycle amplitudes and cycle mean values are extracted and the damage parameter is computed. In contrast to the existing methods the proposed method enables continuous damage parameter computation without the need of waiting for the cycles to close. The limitations of th...

  9. 40 CFR 52.796 - Industrial continuous emission monitoring.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 3 2010-07-01 2010-07-01 false Industrial continuous emission monitoring. 52.796 Section 52.796 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS Indiana § 52.796...

  10. Continuous monitoring of barometric pressure in deep mines

    Energy Technology Data Exchange (ETDEWEB)

    Trutwin, W.; Mironowicz, W.; Wasilewski, S.; Krawczyk, J. [Research and Development Centre for Electrical Engineering and Automation in Mining EMAG, Katowice (Poland)

    2005-07-01

    Barometric pressure and its variation in deep underground workings have a considerable effect on ventilation conditions. Pressure changes which create transient states of air flow and air parameters in workings are especially significant. Experiments have shown that pressure changes have a remarkable effect on air parameters at mine workings. Continuous monitoring of the barometric pressure on the surface of mines allows for the detection of changes in pressure which influence alternations of pressure in the underground areas of mines. Important factors are the internal disturbances of pressure within a mine ventilation system due to variable conditions of fan operation and the operation of a winding machine where a mine cage moving in a shaft causes piston like disturbances. Local transient disturbances caused by temporary opening/closing of air stoppings due to personnel or underground transport traffic are of importance. The results of over two years of observations of barometric pressure and its influence on pressure variation in underground mine workings are presented. The observations were possible through the installation of pressure sensors at selected points of the downcast shaft in a mine. Of interest are the observations of the transient states of pressure and other air parameters caused by emergency fan stoppage, movement of a mine cage and changes due to the opening of air stoppings. Data acquired during experiments of opening and closing air stoppings were used for the validation of a flow model in a long working. 13 refs., 15 figs.

  11. Serious games for elderly continuous monitoring.

    Science.gov (United States)

    Lemus-Zúñiga, Lenin-G; Navarro-Pardo, Esperanza; Moret-Tatay, Carmen; Pocinho, Ricardo

    2015-01-01

    Information technology (IT) and serious games allow older population to remain independent for longer. Hence, when designing technology for this population, developmental changes, such as attention and/or perception, should be considered. For instance, a crucial developmental change has been related to cognitive speed in terms of reaction time (RT). However, this variable presents a skewed distribution that difficult data analysis. An alternative strategy is to characterize the data to an ex-Gaussian function. Furthermore, this procedure provides different parameters that have been related to underlying cognitive processes in the literature. Another issue to be considered is the optimal data recording, storing and processing. For that purpose mobile devices (smart phones and tablets) are a good option for targeting serious games where valuable information can be stored (time spent in the application, reaction time, frequency of use, and a long etcetera). The data stored inside the smartphones and tablets can be sent to a central computer (cloud storage) in order to store the data collected to not only fill the distribution of reaction times to mathematical functions, but also to estimate parameters which may reflect cognitive processes underlying language, aging, and decisional process.

  12. Groundwater pollution: Are we monitoring appropriate parameters ...

    African Journals Online (AJOL)

    However, in practice groundwater quality monitoring is the main tool for timely ... quality is a specialised task for a hydrogeologist and a water quality monitoring expert. Although general prescriptions for waste management facilities exist these ... approaches have identified various sets of pollutants and pollution indicators.

  13. Monitoring of conventional environmental parameters at CERN Annual Report 2004

    CERN Document Server

    Dziewa, A

    2005-01-01

    The monitoring programme for conventional environmental parameters at CERN comprises the control of water released from CERN installations, checks of water quality in rivers receiving water from CERN and monitoring of ambient air quality at places close to the CERN sites. The control of released water includes continuous monitoring of pH and temperature at six CERN water outlets and periodical sampling and analysis campaigns to check in more details the quality of the water released from the CERN sites. Sporadic river-water analyses and regular measurements of pH, temperature, concentration of dissolved oxygen and conductivity, were performed in the water of the rivers Nant d'Avril (CH) and Le Lion (F) as well as in the water of the streams around the seven LHC sites PA2 − PA8. The concentrations of nitrogen oxides and ozone in the ambient air, which may be produced in accelerator facilities and released into the environment, were measured at two off-site monitoring stations in Maisonnex (CH) and Cessy (F)....

  14. Monitoring of conventional environmental parameters at CERN Annual Report 2003

    CERN Document Server

    Kleiner, S

    2004-01-01

    The monitoring programme for conventional environmental parameters at CERN comprises the control of water released from CERN installations, checks of water quality in rivers receiving water from CERN and monitoring of ambient air quality at places close to the CERN sites. The control of released water includes continuous monitoring of pH and temperature at six CERN water outlets and periodical sampling and analysis campaigns to check in more details the quality of the water released from the CERN sites. Regular measurements of pH, temperature, concentration of dissolved oxygen and conductivity were performed in the water of the rivers Nant d'Avril (CH) and Le Lion (F) as well as in the water of the streams around the seven LHC sites PA2 − PA8. The concentrations of nitrogen oxides and ozone in the ambient air, which may be produced in accelerator facilities and released into the environment, were measured at two off-site monitoring stations in Maisonnex (CH) and Cessy (F). The report summarises the results ...

  15. Continuous damage parameter calculation under thermo-mechanical random loading.

    Science.gov (United States)

    Nagode, Marko

    2014-01-01

    The paper presents a method on how the mean stress effect on fatigue damage can be taken into account under an arbitrary low cycle thermo-mechanical loading. From known stress, elastoplastic strain and temperature histories the cycle amplitudes and cycle mean values are extracted and the damage parameter is computed. In contrast to the existing methods the proposed method enables continuous damage parameter computation without the need of waiting for the cycles to close. The limitations of the standardized damage parameters are thus surpassed. The damage parameters derived initially for closed and isothermal cycles assuming that the elastoplastic stress-strain response follows the Masing and memory rules can now be used to take the mean stress effect into account under an arbitrary low cycle thermo-mechanical loading. The method includes:•stress and elastoplastic strain history transformation into the corresponding amplitude and mean values;•stress and elastoplastic strain amplitude and mean value transformation into the damage parameter amplitude history;•damage parameter amplitude history transformation into the damage parameter history.

  16. An assessment of acid rock drainage continuous monitoring technology

    Science.gov (United States)

    Fytas, K.; Hadjigeorgiou, J.

    1995-02-01

    In order to assess the magnitude and impact at affected mine sites of acid rock drainage (ARD), fixed-frequency sampling is often employed. This often involves manual sampling, at regular time intervals, of water and solids. It is felt that such sampling does not adequately describe the system evolution. Continuous monitoring offers a viable alternative in that it can better follow the seasonal fluctuations and high-frequency variations that characterize ARD. This paper evaluates existing continuous monitoring technology.

  17. Solar powered wrist worn acquisition system for continuous photoplethysmogram monitoring.

    Science.gov (United States)

    Dieffenderfer, James P; Beppler, Eric; Novak, Tristan; Whitmire, Eric; Jayakumar, Rochana; Randall, Clive; Qu, Weiguo; Rajagopalan, Ramakrishnan; Bozkurt, Alper

    2014-01-01

    We present a solar-powered, wireless, wrist-worn platform for continuous monitoring of physiological and environmental parameters during the activities of daily life. In this study, we demonstrate the capability to produce photoplethysmogram (PPG) signals using this platform. To adhere to a low power budget for solar-powering, a 574 nm green light source is used where the PPG from the radial artery would be obtained with minimal signal conditioning. The system incorporates two monocrystalline solar cells to charge the onboard 20 mAh lithium polymer battery. Bluetooth Low Energy (BLE) is used to tether the device to a smartphone that makes the phone an access point to a dedicated server for long term continuous storage of data. Two power management schemes have been proposed depending on the availability of solar energy. In low light situations, if the battery is low, the device obtains a 5-second PPG waveform every minute to consume an average power of 0.57 mW. In scenarios where the battery is at a sustainable voltage, the device is set to enter its normal 30 Hz acquisition mode, consuming around 13.7 mW. We also present our efforts towards improving the charge storage capacity of our on-board super-capacitor.

  18. Continuous-flow free acid monitoring method and system

    Science.gov (United States)

    Strain, J.E.; Ross, H.H.

    1980-01-11

    A free acid monitoring method and apparatus is provided for continuously measuring the excess acid present in a process stream. The disclosed monitoring system and method is based on the relationship of the partial pressure ratio of water and acid in equilibrium with an acid solution at constant temperature. A portion of the process stream is pumped into and flows through the monitor under the influence of gravity and back to the process stream. A continuous flowing sample is vaporized at a constant temperature and the vapor is subsequently condensed. Conductivity measurements of the condensate produces a nonlinear response function from which the free acid molarity of the sample process stream is determined.

  19. Continuous Security and Configuration Monitoring of HPC Clusters

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Lomeli, H. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bertsch, A. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Fox, D. M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-05-08

    Continuous security and configuration monitoring of information systems has been a time consuming and laborious task for system administrators at the High Performance Computing (HPC) center. Prior to this project, system administrators had to manually check the settings of thousands of nodes, which required a significant number of hours rendering the old process ineffective and inefficient. This paper explains the application of Splunk Enterprise, a software agent, and a reporting tool in the development of a user application interface to track and report on critical system updates and security compliance status of HPC Clusters. In conjunction with other configuration management systems, the reporting tool is to provide continuous situational awareness to system administrators of the compliance state of information systems. Our approach consisted of the development, testing, and deployment of an agent to collect any arbitrary information across a massively distributed computing center, and organize that information into a human-readable format. Using Splunk Enterprise, this raw data was then gathered into a central repository and indexed for search, analysis, and correlation. Following acquisition and accumulation, the reporting tool generated and presented actionable information by filtering the data according to command line parameters passed at run time. Preliminary data showed results for over six thousand nodes. Further research and expansion of this tool could lead to the development of a series of agents to gather and report critical system parameters. However, in order to make use of the flexibility and resourcefulness of the reporting tool the agent must conform to specifications set forth in this paper. This project has simplified the way system administrators gather, analyze, and report on the configuration and security state of HPC clusters, maintaining ongoing situational awareness. Rather than querying each cluster independently, compliance checking

  20. Improvement of Continuous Hydrologic Models and HMS SMA Parameters Reduction

    Science.gov (United States)

    Rezaeian Zadeh, Mehdi; Zia Hosseinipour, E.; Abghari, Hirad; Nikian, Ashkan; Shaeri Karimi, Sara; Moradzadeh Azar, Foad

    2010-05-01

    Hydrological models can help us to predict stream flows and associated runoff volumes of rainfall events within a watershed. There are many different reasons why we need to model the rainfall-runoff processes of for a watershed. However, the main reason is the limitation of hydrological measurement techniques and the costs of data collection at a fine scale. Generally, we are not able to measure all that we would like to know about a given hydrological systems. This is very particularly the case for ungauged catchments. Since the ultimate aim of prediction using models is to improve decision-making about a hydrological problem, therefore, having a robust and efficient modeling tool becomes an important factor. Among several hydrologic modeling approaches, continuous simulation has the best predictions because it can model dry and wet conditions during a long-term period. Continuous hydrologic models, unlike event based models, account for a watershed's soil moisture balance over a long-term period and are suitable for simulating daily, monthly, and seasonal streamflows. In this paper, we describe a soil moisture accounting (SMA) algorithm added to the hydrologic modeling system (HEC-HMS) computer program. As is well known in the hydrologic modeling community one of the ways for improving a model utility is the reduction of input parameters. The enhanced model developed in this study is applied to Khosrow Shirin Watershed, located in the north-west part of Fars Province in Iran, a data limited watershed. The HMS SMA algorithm divides the potential path of rainfall onto a watershed into five zones. The results showed that the output of HMS SMA is insensitive with the variation of many parameters such as soil storage and soil percolation rate. The study's objective is to remove insensitive parameters from the model input using Multi-objective sensitivity analysis. Keywords: Continuous Hydrologic Modeling, HMS SMA, Multi-objective sensitivity analysis, SMA Parameters

  1. Technical parameters in electromagnetic continuous casting of aluminum alloy

    Institute of Scientific and Technical Information of China (English)

    李玉梅; 张兴国; 贾非; 姚山; 金俊泽

    2003-01-01

    The temperature field of aluminum ingot during electromagnetic continuous casting was calculated by the numerical method, and the effects of cooling water strength, position of the cooling water holes and pouring temperature as well as induction heat on casting speed, were studied. The results show that among the technical parameters the distance from the position of the cooling water holes to the bottom of the mold is the most important factor, whose change from 20mm to 15mm and from 15mm to 10mm causes the setting rate increasing respectively by 0.14mm/s and 0.3mm/s.The calculated results also agree with the experiment well. The simulation program can be used to determine technical parameters of electromagnetic casting of aluminum ingot effectively.

  2. New fluorescence parameters for monitoring photosynthesis in plants.

    Science.gov (United States)

    Force, Lesleigh; Critchley, Christa; van Rensen, Jack J S

    2003-01-01

    Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation

  3. Low Cost Wireless Sensor Network for Continuous Bridge monitoring

    DEFF Research Database (Denmark)

    Han, Bo; Kalis, A; Tragas, P

    2012-01-01

    Continuous monitoring wireless sensor networks (WSN) are considered as one of the most promising means to harvest information from large structures in order to assist in structural health monitoring and management. At the same time, continuous monitoring WSNs suffer from limited network lifetimes...... the network increases. Therefore, in order for WSNs to be considered as an efficient tool to monitor the health state of large structures, their energy consumption should be reduced to a bare minimum. In this work we consider a couple of novel techniques for increasing the life-time of the sensor network......, related to both node and network architecture. Namely, we consider new node de-signs that are of low cost, low complexity, and low energy consumption. Moreover, we present a new net-work architecture for such small nodes, that would enable them to reach a base station at large distances from the network...

  4. LIKELIHOOD ESTIMATION OF PARAMETERS USING SIMULTANEOUSLY MONITORED PROCESSES

    DEFF Research Database (Denmark)

    Friis-Hansen, Peter; Ditlevsen, Ove Dalager

    2004-01-01

    The topic is maximum likelihood inference from several simultaneously monitored response processes of a structure to obtain knowledge about the parameters of other not monitored but important response processes when the structure is subject to some Gaussian load field in space and time. The consi......The topic is maximum likelihood inference from several simultaneously monitored response processes of a structure to obtain knowledge about the parameters of other not monitored but important response processes when the structure is subject to some Gaussian load field in space and time....... The considered example is a ship sailing with a given speed through a Gaussian wave field....

  5. Evaluating clinical accuracy of continuous glucose monitoring devices: other methods.

    Science.gov (United States)

    Wentholt, Iris M E; Hart, August A; Hoekstra, Joost B L; DeVries, J Hans

    2008-08-01

    With more and more continuous glucose monitoring devices entering the market, the importance of adequate accuracy assessment grows. This review discusses pros and cons of Regression Analysis and Correlation Coefficient, Relative Difference measures, Bland Altman plot, ISO criteria, combined curve fitting, and epidemiological analyses, the latter including sensitivity, specificity and positive predictive value for hypoglycaemia. Finally, recommendations for much needed head-to-head studies are given. This paper is a revised and adapted version of How to assess and compare the accuracy of continuous glucose monitors?, Diabetes Technology and Therapeutics 2007, in press, published with permission of the editor.

  6. Development of multianalyte sensor arrays for continuous monitoring of pollutants

    Energy Technology Data Exchange (ETDEWEB)

    Milanovich, F.P.; Richards, J.B.; Brown, S.B. [Lawrence Livermore National Lab., CA (United States); Healey, B.G.; Chadha, S.; Walt, D. [Tufts Univ., Medford, MA (United States)

    1995-01-01

    Industrial development has led to the release of numerous hazardous materials into the environment posing a potential threat to surrounding waters. Environmental analysis of sites contaminated by several chemicals calls for continuous monitoring of multiple analytes. Monitoring can be achieved by using imaging bundles (300--400 {micro}m in diameter), containing several thousand individual optical fibers for the fabrication of sensors. Multiple sensor sites are created at the distal end of the fiber by immobilizing different analyte-specific fluorescent dyes. By coupling these imaging fibers to a charge coupled device (CCD), one has the ability to spatially and spectrally discriminate the multiple sensing sites simultaneously and hence monitor analyte concentrations.

  7. An Architecture for Continuous Data Quality Monitoring in Medical Centers.

    Science.gov (United States)

    Endler, Gregor; Schwab, Peter K; Wahl, Andreas M; Tenschert, Johannes; Lenz, Richard

    2015-01-01

    In the medical domain, data quality is very important. Since requirements and data change frequently, continuous and sustainable monitoring and improvement of data quality is necessary. Working together with managers of medical centers, we developed an architecture for a data quality monitoring system. The architecture enables domain experts to adapt the system during runtime to match their specifications using a built-in rule system. It also allows arbitrarily complex analyses to be integrated into the monitoring cycle. We evaluate our architecture by matching its components to the well-known data quality methodology TDQM.

  8. Continuous Hemodynamic Monitoring in Acute Stroke: An Exploratory Analysis

    Directory of Open Access Journals (Sweden)

    Ayan Sen

    2014-07-01

    Full Text Available Introduction: Non-invasive, continuous hemodynamic monitoring is entering the clinical arena. The primary objective of this study was to test the feasibility of such monitoring in a pilot sample of Emergency Department (ED stroke patients. Secondary objectives included analysis of hemodynamic variability and correlation of continuous blood pressure measurements with standard measurements. Methods: This study was a secondary analysis of 7 stroke patients from a prospectively collected data set of patients that received 2 hours of hemodynamic monitoring in the ED. Stroke patients were included if hemorrhagic or ischemic stroke was confirmed by neuroimaging, and symptom onset was within 24 hours. They were excluded for the presence of a stroke mimic or transient ischemic attack. Monitoring was performed using the Nexfin device (Edwards Lifesciences, Irvine CA. Results: The mean age of the cohort was 71 ± 17 years, 43% were male, and the mean National Institute of Health Stroke Scale (NIHSS was 6.9 ± 5.5. Two patients had hemorrhagic stroke. We obtained 42,456 hemodynamic data points, including beat-to-beat blood pressure measurements with variability of 18 mmHg and cardiac indices ranging from 1.8 to 3.6 l/min/m2. The correlation coefficient between continuous blood pressure measurements with the Nexfin device and standard ED readings was 0.83. Conclusion: This exploratory investigation revealed that continuous, noninvasive monitoring in the ED is feasible in acute stroke. Further research is currently underway to determine how such monitoring may impact outcomes in stroke or replace the need for invasive monitoring. [West J Emerg Med. 2014;15(4:–0.

  9. A Seismic Transmission System for Continuous Monitoring of the Lithosphere: A Proposition

    NARCIS (Netherlands)

    Unger, R.

    2002-01-01

    The main objective of this thesis is to enhance earthquake prediction feasibility. We present the concept and the design layout of a novel seismic transmission system capable of continuously monitoring the Lithosphere for changes in Earth physics parameters governing seismic wave propagation. New-te

  10. A Seismic Transmission System for Continuous Monitoring of the Lithosphere: A Proposition

    NARCIS (Netherlands)

    Unger, R.

    2002-01-01

    The main objective of this thesis is to enhance earthquake prediction feasibility. We present the concept and the design layout of a novel seismic transmission system capable of continuously monitoring the Lithosphere for changes in Earth physics parameters governing seismic wave propagation.

  11. A Seismic Transmission System for Continuous Monitoring of the Lithosphere: A Proposition

    NARCIS (Netherlands)

    Unger, R.

    2002-01-01

    The main objective of this thesis is to enhance earthquake prediction feasibility. We present the concept and the design layout of a novel seismic transmission system capable of continuously monitoring the Lithosphere for changes in Earth physics parameters governing seismic wave propagation. New-te

  12. A versatile biosensor device for continuous biomedical monitoring

    NARCIS (Netherlands)

    Rhemrev-Boom, MM; Korf, J; Venema, K; Urban, G; Vadgama, P

    2001-01-01

    Although biosensors are by means suitable for continuous biomedical monitoring, due to fouling and blood clotting, in vivo performance is far from optimal. For this reason, ultrafiltration, microdialysis or open tubular flow is frequently used as interface. To secure quantitative recoveries of the a

  13. [Usefulness of IPC continuous monitoring in shunt dysfunction].

    Science.gov (United States)

    Horcajadas, A; Román, A; Olivares, G; Saura, E; Jorques, A; Cordero, N; Ibáñez, B; Sánchez, C; Roldán, M A

    2011-08-01

    Shunt dysfunction is a common situation in neurosurgery. Often symptoms, physical examination and radiology are not enough to set a diagnosis. ICP continuous monitoring is a safe and reliable tool that provides valuable information about CSF dynamics in these patients. Not only quantitative analysis is needed but also a qualitative one that enables pathological waves identification, because high amplitude B waves are strongly related to shunt dysfunction. In this paper experience about ICP continuous monitoring in patients with shunt dysfunction suspect is presented. Quantitative and qualitative data analysis led to a correct diagnosis, improving all the patients treated according to this criterion. An intraparenchymatous Camino® sensor and neuroPICture software (developed by first author) for data collection and graphic representation were used. Complications related to monitoring were absent and graphics obtained useful for qualitative analysis.

  14. A Seismic Transmission System for Continuous Monitoring of the Lithosphere: A Proposition

    OpenAIRE

    Unger, R.

    2002-01-01

    The main objective of this thesis is to enhance earthquake prediction feasibility. We present the concept and the design layout of a novel seismic transmission system capable of continuously monitoring the Lithosphere for changes in Earth physics parameters governing seismic wave propagation. New-technology seismic vibrator sources (magnetic levitation vibrator, linear synchronous motor vibrator) transmit, in continuously repeatable fashion, mutually uncorrelated, low-frequency signals simult...

  15. Catalytic sensor based continuous emissions monitor in boiler applications

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, P.F.; Devita, S.P.; Budd, A. [Monitor Labs, Inc., Englewood, CO (United States)

    1997-12-31

    Until the development of reliable, solid state NO{sub x} sensors, sensor based continuous monitoring of NO{sub x} emissions was primarily by predictive or parametric methods which use data collected from other types of sensors to predict what a NO{sub x} sensor would read. While some success has been achieved using these methods, direct measurement of desired exhaust gases provides greater confidence than can be achieved using modeling approaches. The recent development of a solid state catalytic NO{sub x} sensor allowed development of an analyzer combining the advantages of sensors with the direct measurement capability of traditional continuous emissions monitors. The new sensor based analyzer, the CEMcat{trademark} continuous emissions monitor, utilizes a single, compact, sensor module containing the three sensors for NO{sub x}, CO and O{sub 2} measurement. Its development was sponsored by the Gas Research Institute (GRI), and additional support was provided by the Southern California Gas Co. The use of the CEMcat analyzer to monitor emissions from gas turbine engines and large gas-fired reciprocating engines has previously been reported. In these applications, the CEMcat analyzer demonstrated its capability to meet 40CFR60 relative accuracy requirements. This sensor based analyzer has recently been applied in boiler applications.

  16. Research on an active and continuous monitoring system for human respiratory system

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    Continuous and dynamic measurements of human respiratory parameters are very important for vital diseases of respiratory system during mechanical ventilation. This paper analyzed the structure and mechanical properties of the human respiratory system, and designed an active intervening monitoring micro system for it. The mobile mechanism of the micro system is soft and earthworm-like movement actuated by pneumatic rubber actuator, the measurement and therapy unit of the system is an extensible mechanism with sensors in the front. The micro monitoring system can move in respiratory tract and measure the respiratory parameters in bronchium continuously. Experiments had been done in swine's respiratory tract,the results proved that the micro robot system could measure the respiratory parameters in real-time successfully and its movement was smooth in swine's respiratory tract.

  17. Landsat continuity: Issues and opportunities for land cover monitoring

    Science.gov (United States)

    Wulder, M.A.; White, Joanne C.; Goward, S.N.; Masek, J.G.; Irons, J.R.; Herold, M.; Cohen, W.B.; Loveland, T.R.; Woodcock, C.E.

    2008-01-01

    Initiated in 1972, the Landsat program has provided a continuous record of earth observation for 35??years. The assemblage of Landsat spatial, spectral, and temporal resolutions, over a reasonably sized image extent, results in imagery that can be processed to represent land cover over large areas with an amount of spatial detail that is absolutely unique and indispensable for monitoring, management, and scientific activities. Recent technical problems with the two existing Landsat satellites, and delays in the development and launch of a successor, increase the likelihood that a gap in Landsat continuity may occur. In this communication, we identify the key features of the Landsat program that have resulted in the extensive use of Landsat data for large area land cover mapping and monitoring. We then augment this list of key features by examining the data needs of existing large area land cover monitoring programs. Subsequently, we use this list as a basis for reviewing the current constellation of earth observation satellites to identify potential alternative data sources for large area land cover applications. Notions of a virtual constellation of satellites to meet large area land cover mapping and monitoring needs are also presented. Finally, research priorities that would facilitate the integration of these alternative data sources into existing large area land cover monitoring programs are identified. Continuity of the Landsat program and the measurements provided are critical for scientific, environmental, economic, and social purposes. It is difficult to overstate the importance of Landsat; there are no other systems in orbit, or planned for launch in the short-term, that can duplicate or approach replication, of the measurements and information conferred by Landsat. While technical and political options are being pursued, there is no satellite image data stream poised to enter the National Satellite Land Remote Sensing Data Archive should system failures

  18. The Use of Continuous Electrocardiographic Holter Monitoring in Pediatric Cardiology.

    Science.gov (United States)

    Begic, Zijo; Begic, Edin; Mesihovic-Dinarevic, Senka; Masic, Izet; Pesto, Senad; Halimic, Mirza; Kadic, Almira; Dobraca, Amra

    2016-07-16

    To show the place and role of continuous electrocardiographic twenty-four-hour ECG monitoring in daily clinical practice of pediatric cardiologists. According to protocol, 2753 patients underwent dynamic continuous ECG Holter monitoring (data collected from the "Register of ECG Holter monitoring" of Pediatric Clinic, UCC Sarajevo in period April 2003- April 2015). There were 50,5% boys and 49,5% girls, aged from birth to 19 years (1,63% - neonates and infants, 2,6% - toddlers, 9,95% - preschool children, 35,5% - gradeschoolers and 50,3% children in puberty and adolescence). In 68,1% of patients Holter was performed for the first time. Indications for conducting Holter were: arrhythmias in 42,2% cases, precordial pain in 23,5%, suspicion of pre-excitation and/or pre-excitation in 10%, crisis of consciousness in 8%, uncorrected congenital/acquired heart defects in 4,2%, operated heart defects in 3,7%, hypertension in 3,1% cases, control of the pacemaker in 1,63% and other causes in 3,5% cases. Discharge diagnosis after ECG Holter monitoring were: insignificant arrhythmias in 47,1% cases, wandering pacemaker in 21,3%, pre-excitation in 16,2%, benign ventricular premature beats in 6,3%, atrioventricular block in 3%, sinus pause in 2.2% cases and other arrhythmias in 3,5%. In mentioned period 57 cases of Wolf Parkinson White syndrome were registered, in 4,5% of patients antiarrhythmic therapy was administered. Radiofrequent ablation was performed in 23 cases. The development of pediatric cardiac surgery has initiated development of pediatric arrhythmology as imperative segment of pediatric cardiology. Continuous ECG Holter monitoring has become irreplaceable method in everyday diagnostics and therapy of arrhythmias in children.

  19. Continuous mine environmental monitoring system - a case study

    Energy Technology Data Exchange (ETDEWEB)

    Tripathy, D.P.; Sahu, H.B. [Regional Engineering College, Rourkela (India)

    2001-07-01

    The introduction of continuous remote environmental monitoring and control systems in modern coal mines is a great step forward in achieving increased mine safety, higher productivity and effective utilization of manpower. They provide alarms and displays of early warnings and impending dangerous conditions in the mine. They also provide facilities to monitor and control air quality, differential pressure, noise etc. Telemetry systems have distinct advantages over the old tube bundle techniques and are being increasingly used. This article discusses in detail the basic components and the functioning of telemonitoring systems in use with special reference to Colliery A, a degree-1 gassy coal mine worked by the bord and pillar method. The system monitors and processes data on temperature, methane and carbon monoxide. 1 figs., 3 tabs.

  20. A wearable multisensing patch for continuous sweat monitoring

    OpenAIRE

    Anastasova, Salzitsa; Crewther, Blair; Bembnowicz, Pawel; Curto, Vincenzo; Ip, Henry MD; Rosa, Bruno; Yang, Guang-Zhong

    2016-01-01

    In sport, exercise and healthcare settings, there is a need for continuous, non-invasive monitoring of biomarkers to assess human performance, health and wellbeing. Here we report the development of a flexible microfluidic platform with fully integrated sensing for on-body testing of human sweat. The system can simultaneously and selectively measure metabolite (e.g. lactate) and electrolytes (e.g. pH, sodium) together with temperature sensing for internal calibration. The construction of the ...

  1. Continuous intra-arterial blood-gas monitoring

    Science.gov (United States)

    Divers, George A.; Riccitelli, Samuel D.; Blais, Maurice; Hui, Henry K.

    1993-05-01

    Fiber optic technology and optical fluorescence have made the continuous monitoring of arterial blood gases a reality. Practical products that continuously monitor blood gases by use of an invasive sensor are now available. Anesthesiologists and intensive care physicians are beginning to explore the practical implications of this technology. With the advent of intra- arterial blood gas monitors it is possible to assess arterial blood gas values without the labor intensive steps of drawing blood and transporting a blood sample to the lab followed by the actual analysis. These intra-arterial blood gas monitors use new optical sensor technologies that can be reduced in size to the point that the sensor can be inserted into the arterial blood flow through a 20-gauge arterial cannula. In the best of these technologies the sensors accuracy and precision are similar to those in vitro analyzers. This presentation focuses on background technology and in vivo performance of a device developed, manufactured, and marketed by Puritan-Bennett Corporation.

  2. Sensor packaging design for continuous underfoot load monitoring.

    Science.gov (United States)

    North, Kylee; Kubiak, Erik N; Hitchcock, Robert W

    2012-02-01

    Continuous force measurement can provide valuable insight to the efficacy of limb loading regimes during fracture rehabilitation. Currently there is no load monitoring device that is capable of more than 1 h of continuous recording. To enable continuous underfoot load monitoring a piezoresistive pressure sensor was encapsulated in a non-compressible silicone gel. This basic approach to signal transduction was implemented in three continuous underfoot load sensor designs. Design I constrained the gel in a rigid urethane housing. Design II constrained the gel in a silicone elastomer bladder. Design III utilized a hybrid approach by constraining the gel with a rigid upperplate inside of an elastomeric bladder. All three designs were subjected to bench and human testing. Design I outperformed the other two designs showing high linearity (correlation coefficient of 1), low static drift (<1%) and low dynamic drift (<3%) and captured the largest percentage of weight during human testing (35%). The sensor was designed, tested and shown to be durable and accurate for a 2 week window of time. This sensor has the low cost and high performance required for large scale clinical tests to correlate limb loading and fracture healing rates.

  3. Noninvasive continuous monitoring of digital pulse waves during hemodialysis

    DEFF Research Database (Denmark)

    Burkert, Antje; Scholze, Alexandra; Tepel, Martin

    2009-01-01

    Intermittent hemodynamic instability during hemodialysis treatment is a frequent complication in patients with end-stage renal failure. A noninvasive method for continuous hemodynamic monitoring is needed. We used noninvasive digital photoplethysmography and an algorithm for continuous, investiga......Intermittent hemodynamic instability during hemodialysis treatment is a frequent complication in patients with end-stage renal failure. A noninvasive method for continuous hemodynamic monitoring is needed. We used noninvasive digital photoplethysmography and an algorithm for continuous......, investigator-independent, automatic analysis of digital volume pulse in 10 healthy subjects and in 20 patients with end-stage renal failure during the hemodialysis session. The reflective index was defined representing the diastolic component of the digital pulse wave. The properties of the reflective index...... were studied in healthy control subjects (n=10). An increased reflective index was due to increased peripheral pulse wave reflection (e.g., vasoconstriction). During a hemodialysis session, the reflective index increased significantly from 36+/-3 arbitrary units to 41+/-3 arbitrary units (n=20; p...

  4. The Use of Continuous Electrocardiographic Holter Monitoring in Pediatric Cardiology

    Science.gov (United States)

    Begic, Zijo; Begic, Edin; Mesihovic-Dinarevic, Senka; Masic, Izet; Pesto, Senad; Halimic, Mirza; Kadic, Almira; Dobraca, Amra

    2016-01-01

    Objective: To show the place and role of continuous electrocardiographic twenty-four-hour ECG monitoring in daily clinical practice of pediatric cardiologists. Methods: According to protocol, 2753 patients underwent dynamic continuous ECG Holter monitoring (data collected from the “Register of ECG Holter monitoring” of Pediatric Clinic, UCC Sarajevo in period April 2003- April 2015). Results: There were 50,5% boys and 49,5% girls, aged from birth to 19 years (1,63% - neonates and infants, 2,6% - toddlers, 9,95% - preschool children, 35,5% - gradeschoolers and 50,3% children in puberty and adolescence). In 68,1% of patients Holter was performed for the first time. Indications for conducting Holter were: arrhythmias in 42,2% cases, precordial pain in 23,5%, suspicion of pre-excitation and/or pre-excitation in 10%, crisis of consciousness in 8%, uncorrected congenital/acquired heart defects in 4,2%, operated heart defects in 3,7%, hypertension in 3,1% cases, control of the pacemaker in 1,63% and other causes in 3,5% cases. Discharge diagnosis after ECG Holter monitoring were: insignificant arrhythmias in 47,1% cases, wandering pacemaker in 21,3%, pre-excitation in 16,2%, benign ventricular premature beats in 6,3%, atrioventricular block in 3%, sinus pause in 2.2% cases and other arrhythmias in 3,5%. In mentioned period 57 cases of Wolf Parkinson White syndrome were registered, in 4,5% of patients antiarrhythmic therapy was administered. Radiofrequent ablation was performed in 23 cases. Conclusion: The development of pediatric cardiac surgery has initiated development of pediatric arrhythmology as imperative segment of pediatric cardiology. Continuous ECG Holter monitoring has become irreplaceable method in everyday diagnostics and therapy of arrhythmias in children. PMID:27708487

  5. Continuous gravity monitoring of geothermal activity; Renzoku juryoku sokutei ni yoru chinetsu katsudo no monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, M. [Geological Survey of Japan, Tsukuba (Japan)

    1997-05-27

    To clarify the geothermal activity in the geothermal fields in New Zealand, gravity monitoring was conducted using SCINTREX automatic gravimeter. The measurements were conducted between the end of January and the beginning of March, 1996. Firstly, continuous monitoring was conducted at the standard point for about ten days, and the tidal components were estimated from the records. After that, continuous monitoring was conducted at Waimangu area for several days. Continuous monitoring was repeated at the standard point, again. At the Waimangu area, three times of changes in the pulse-shape amplitude of 0.01 mgal having a width of several hours were observed. For the SCINTREX gravimeter, the inclination of gravimeter is also recorded in addition to the change of gravity. During the monitoring, the gravimeter was also inclined with the changes of gravity. This inclination was useful not only for the correction of gravity measured, but also for evaluating the ground fluctuation due to the underground pressure source. It is likely that the continuous gravity monitoring is the relatively conventional technique which is effective for prospecting the change of geothermal reservoir. 2 figs.

  6. Bayesian parameter inference from continuously monitored quantum systems

    DEFF Research Database (Denmark)

    Gammelmark, Søren; Mølmer, Klaus

    2013-01-01

    We review the introduction of likelihood functions and Fisher information in classical estimation theory, and we show how they can be defined in a very similar manner within quantum measurement theory. We show that the stochastic master equations describing the dynamics of a quantum system subject...

  7. Continuous Glucose Monitoring Sensors: Past, Present and Future Algorithmic Challenges

    Directory of Open Access Journals (Sweden)

    Andrea Facchinetti

    2016-12-01

    Full Text Available Continuous glucose monitoring (CGM sensors are portable devices that allow measuring and visualizing the glucose concentration in real time almost continuously for several days and are provided with hypo/hyperglycemic alerts and glucose trend information. CGM sensors have revolutionized Type 1 diabetes (T1D management, improving glucose control when used adjunctively to self-monitoring blood glucose systems. Furthermore, CGM devices have stimulated the development of applications that were impossible to create without a continuous-time glucose signal, e.g., real-time predictive alerts of hypo/hyperglycemic episodes based on the prediction of future glucose concentration, automatic basal insulin attenuation methods for hypoglycemia prevention, and the artificial pancreas. However, CGM sensors’ lack of accuracy and reliability limited their usability in the clinical practice, calling upon the academic community for the development of suitable signal processing methods to improve CGM performance. The aim of this paper is to review the past and present algorithmic challenges of CGM sensors, to show how they have been tackled by our research group, and to identify the possible future ones.

  8. Probing Microarcsecond Structure in AGN using Continuous Flux Density Monitoring

    Science.gov (United States)

    Senkbeil, C.; Lovell, J.; Ellingsen, S.; Jauncey, D.; Cimò, G.

    2009-08-01

    Active Galactic Nuclei (AGN) exhibit radio flux density variability on a wide range of time scales from hours to years. The rapid cm-wavelength variability on timescales from hours to days has been shown to be caused by interstellar scintillation. Interstellar scintillation implies the presence of microarcsecond scale structure in the scintillating source. We have quasi-continuously monitored the 6.7 GHz flux density of six interstellar scintillating sources since 2003 using the University of Tasmania Ceduna Radio Telescope. The launch of the VSOP 2 ASTRO-G mission will allow us to compare the microarcsecond AGN structure at 22 and 43 GHz with microarcsecond structure implied by scintillation at 5 GHz using the Hobart Interferometer, which will supersede the Ceduna flux density monitoring program in 2009.

  9. Current and Emerging Technology for Continuous Glucose Monitoring

    Directory of Open Access Journals (Sweden)

    Cheng Chen

    2017-01-01

    Full Text Available Diabetes has become a leading cause of death worldwide. Although there is no cure for diabetes, blood glucose monitoring combined with appropriate medication can enhance treatment efficiency, alleviate the symptoms, as well as diminish the complications. For point-of-care purposes, continuous glucose monitoring (CGM devices are considered to be the best candidates for diabetes therapy. This review focuses on current growth areas of CGM technologies, specifically focusing on subcutaneous implantable electrochemical glucose sensors. The superiority of CGM systems is introduced firstly, and then the strategies for fabrication of minimally-invasive and non-invasive CGM biosensors are discussed, respectively. Finally, we briefly outline the current status and future perspective for CGM systems.

  10. Continuous ammonia monitor using a Stark microwave cavity resonator.

    Science.gov (United States)

    Uehara, H; Ijuuin, Y; Morino, Y; Kamidate, T; Nakamura, A; Imai, H

    1980-03-01

    An ammonia monitor has been made by using a rectangular Stark microwave cavity tightly coupled through an iris to a Gunn oscillator. The Stark electrode installed inside the cavity is provided with a 100 kHz sinusoidal modulation voltage and a dc sweep voltage. The oscillation of the Gunn diode is tuned with the coupled Stark cavity to a frequency near a J,K=3,3 transition (23870.1 MHz) of ammonia. By fixing the Stark dc bias to a voltage which gives a peak intensity of the derivative output of the electric-resonance signal, ammonia is continuously monitored. An extremely good long-term stability is obtained. The noise level corresponds to 0.08 ppm of ammonia.

  11. Tube-Load Model Parameter Estimation for Monitoring Arterial Hemodynamics

    Directory of Open Access Journals (Sweden)

    Guanqun eZhang

    2011-11-01

    Full Text Available A useful model of the arterial system is the uniform, lossless tube with parametric load. This tube-load model is able to account for wave propagation and reflection (unlike lumped-parameter models such as the Windkessel while being defined by only a few parameters (unlike comprehensive distributed-parameter models. As a result, the parameters may be readily estimated by accurate fitting of the model to available arterial pressure and flow waveforms so as to permit improved monitoring of arterial hemodynamics. In this paper, we review tube-load model parameter estimation techniques that have appeared in the literature for monitoring wave reflection, large artery compliance, pulse transit time, and central aortic pressure. We begin by motivating the use of the tube-load model for parameter estimation. We then describe the tube-load model, its assumptions and validity, and approaches for estimating its parameters. We next summarize the various techniques and their experimental results while highlighting their advantages over conventional techniques. We conclude the review by suggesting future research directions and describing potential applications.

  12. Tube-Load Model Parameter Estimation for Monitoring Arterial Hemodynamics

    Science.gov (United States)

    Zhang, Guanqun; Hahn, Jin-Oh; Mukkamala, Ramakrishna

    2011-01-01

    A useful model of the arterial system is the uniform, lossless tube with parametric load. This tube-load model is able to account for wave propagation and reflection (unlike lumped-parameter models such as the Windkessel) while being defined by only a few parameters (unlike comprehensive distributed-parameter models). As a result, the parameters may be readily estimated by accurate fitting of the model to available arterial pressure and flow waveforms so as to permit improved monitoring of arterial hemodynamics. In this paper, we review tube-load model parameter estimation techniques that have appeared in the literature for monitoring wave reflection, large artery compliance, pulse transit time, and central aortic pressure. We begin by motivating the use of the tube-load model for parameter estimation. We then describe the tube-load model, its assumptions and validity, and approaches for estimating its parameters. We next summarize the various techniques and their experimental results while highlighting their advantages over conventional techniques. We conclude the review by suggesting future research directions and describing potential applications. PMID:22053157

  13. Evaluation of ground stiffness parameters using continuous surface wave geophysics

    DEFF Research Database (Denmark)

    Gordon, Anne; Foged, Niels

    2000-01-01

    -small-strain stiffness of the ground Gmax. Continuous surface wave geophysics offers a quick, non-intrusive and economical way of making such measurements. This paper reviews the continuous surface wave techniques and evaluates, in engineering terms, the applicability of the method to the site investigation industry....

  14. Evaluation of ground stiffness parameters using continuous surface wave geophysics

    DEFF Research Database (Denmark)

    Gordon, Anne; Foged, Niels

    2000-01-01

    -small-strain stiffness of the ground Gmax. Continuous surface wave geophysics offers a quick, non-intrusive and economical way of making such measurements. This paper reviews the continuous surface wave techniques and evaluates, in engineering terms, the applicability of the method to the site investigation industry....

  15. Asymptotic failure rate of a continuously monitored system

    Energy Technology Data Exchange (ETDEWEB)

    Grall, A. [Institut des Sciences et Technologies de l' Information de Troyes (CNRS-FRE 2732), Equipe de Modelisation et de Surete des Systemes, Universite de Technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes Cedex (France)]. E-mail: antoine.grall@utt.fr; Dieulle, L. [Institut des Sciences et Technologies de l' Information de Troyes (CNRS-FRE 2732), Equipe de Modelisation et de Surete des Systemes, Universite de Technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes Cedex (France)]. E-mail: laurence.dieulle@utt.fr; Berenguer, C. [Institut des Sciences et Technologies de l' Information de Troyes (CNRS-FRE 2732), Equipe de Modelisation et de Surete des Systemes, Universite de Technologie de Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes Cedex (France)]. E-mail: christophe.berenguer@utt.fr; Roussignol, M. [Laboratoire d' Analyse et de Mathematiques Appliquees, Universite de Marne la Vallee, 5 bd Descartes, Champs sur Marne, 77454 Marne la Vallee, Cedex 2 (France)]. E-mail: michel.roussignol@univ-mlv.fr

    2006-02-01

    This paper deals with a perfectly continuously monitored system which gradually and stochastically deteriorates. The system is renewed by a delayed maintenance operation, which is triggered when the measured deterioration level exceeds an alarm threshold. A mathematical model is developed to study the asymptotic behavior of the reliability function. A procedure is proposed which allows us to identify the asymptotic failure rate of the maintained system. Numerical experiments illustrate the efficiency of the proposed procedure and emphasize the relevance of the asymptotic failure rate as an interesting indicator for the evaluation of the control-limit preventive replacement policy.

  16. A Buoy for Continuous Monitoring of Suspended Sediment Dynamics

    Directory of Open Access Journals (Sweden)

    Andreas Güntner

    2013-10-01

    Full Text Available Knowledge of Suspended Sediments Dynamics (SSD across spatial scales is relevant for several fields of hydrology, such as eco-hydrological processes, the operation of hydrotechnical facilities and research on varved lake sediments as geoarchives. Understanding the connectivity of sediment flux between source areas in a catchment and sink areas in lakes or reservoirs is of primary importance to these fields. Lacustrine sediments may serve as a valuable expansion of instrumental hydrological records for flood frequencies and magnitudes, but depositional processes and detrital layer formation in lakes are not yet fully understood. This study presents a novel buoy system designed to continuously measure suspended sediment concentration and relevant boundary conditions at a high spatial and temporal resolution in surface water bodies. The buoy sensors continuously record turbidity as an indirect measure of suspended sediment concentrations, water temperature and electrical conductivity at up to nine different water depths. Acoustic Doppler current meters and profilers measure current velocities along a vertical profile from the water surface to the lake bottom. Meteorological sensors capture the atmospheric boundary conditions as main drivers of lake dynamics. It is the high spatial resolution of multi-point turbidity measurements, the dual-sensor velocity measurements and the temporally synchronous recording of all sensors along the water column that sets the system apart from existing buoy systems. Buoy data collected during a 4-month field campaign in Lake Mondsee demonstrate the potential and effectiveness of the system in monitoring suspended sediment dynamics. Observations were related to stratification and mixing processes in the lake and increased turbidity close to a catchment outlet during flood events. The rugged buoy design assures continuous operation in terms of stability, energy management and sensor logging throughout the study period

  17. Initial Development of a Continuous Emission Monitor for Dioxins

    Energy Technology Data Exchange (ETDEWEB)

    Michael J. Coggiola; Harald Oser; Gregory W. Faris; David R. Crosley

    2002-03-30

    Under contract DE-AC26-98FT-40370, SRI International has completed the third phase of a planned three-phase effort to develop a laboratory prototype continuous emission monitor (CEM) for dioxins and furans generated during the incineration of waste materials at DOE remediation sites. The project was initiated on July 29, 1998 with the technical effort completed in October 2001. During this research effort, SRI has made numerous improvements in our jet-REMPI instrument. These improvements have involved characterization and optimization of the molecular cooling in the gas jet, implementation of a custom-fabricated, four pulsed valve assembly, new data acquisition and display software, and preliminary development of a wavelength and mass calibration approach. We have also measured the REMPI excitation spectra of numerous organic compounds that are likely to be present in the exhaust stream of a waste incinerator. These spectra must be well characterized in the laboratory to understand any potential interferences that might arise when monitoring for dioxin and furan congeners. Our results to date continue to validate the original concept of using jet-REMPI as the detection method in a dioxin CEM. Using only commercial components with minor modifications, we have already demonstrated a detection sensitivity in the low ppt range with sufficient chemical specificity to separately detect two closely related congeners of dichlorodibenzodioxin present in a mixture. To demonstrate the utility of this methodology outside of the controlled conditions of the laboratory, we performed a series of pseudo-field experiments at the US Environmental Protection Agency's National Risk Management Research Laboratory, Research Triangle Park, NC. The instrument used for those studies was built by SRI under contract with US EPA, and was an exact duplicate of the SRI system. This duplication allowed the experiments to be conducted without transporting the SRI system to the EPA site

  18. Performance of a newly designed continuous soot monitoring system (COSMOS).

    Science.gov (United States)

    Miyazaki, Yuzo; Kondo, Yutaka; Sahu, Lokesh K; Imaru, Junichi; Fukushima, Nobuhiko; Kano, Minoru

    2008-10-01

    We designed a continuous soot monitoring system (COSMOS) for fully automated, high-sensitivity, continuous measurement of light absorption by black carbon (BC) aerosols. The instrument monitors changes in transmittance across an automatically advancing quartz fiber filter tape using an LED at a 565 nm wavelength. To achieve measurements with high sensitivity and a lower detectable light absorption coefficient, COSMOS uses a double-convex lens and optical bundle pipes to maintain high light intensity and signal data are obtained at 1000 Hz. In addition, sampling flow rate and optical unit temperature are actively controlled. The inlet line for COSMOS is heated to 400 degrees C to effectively volatilize non-refractory aerosol components that are internally mixed with BC. In its current form, COSMOS provides BC light absorption measurements with a detection limit of 0.45 Mm(-1) (0.045 microg m(-3) for soot) for 10 min. The unit-to-unit variability is estimated to be within +/- 1%, demonstrating its high reproducibility. The absorption coefficients determined by COSMOS agreed with those by a particle soot absorption photometer (PSAP) to within 1% (r2 = 0.97). The precision (+/- 0.60 Mm(-1)) for 10 min integrated data was better than that of PSAP and an aethalometer under our operating conditions. These results showed that COSMOS achieved both an improved detection limit and higher precision for the filter-based light absorption measurements of BC compared to the existing methods.

  19. APPLICATIONS OF CURRENT TECHNOLOGY FOR CONTINUOUS MONITORING OF SPENT FUEL

    Energy Technology Data Exchange (ETDEWEB)

    Drayer, R.

    2013-06-09

    Advancements in technology have opened many opportunities to improve upon the current infrastructure surrounding the nuclear fuel cycle. Embedded devices, very small sensors, and wireless technology can be applied to Security, Safety, and Nonproliferation of Spent Nuclear Fuel. Security, separate of current video monitoring systems, can be improved by integrating current wireless technology with a variety of sensors including motion detection, altimeter, accelerometer, and a tagging system. By continually monitoring these sensors, thresholds can be set to sense deviations from nominal values. Then alarms or notifications can be activated as needed. Safety can be improved in several ways. First, human exposure to ionizing radiation can be reduced by using a wireless sensor package on each spent fuel cask to monitor radiation, temperature, humidity, etc. Since the sensor data is monitored remotely operator stay-time is decreased and distance from the spent fuel increased, so the overall radiation exposure is reduced as compared to visual inspections. The second improvement is the ability to monitor continuously rather than periodically. If changes occur to the material, alarm thresholds could be set and notifications made to provide advanced notice of negative data trends. These sensor packages could also record data to be used for scientific evaluation and studies to improve transportation and storage safety. Nonproliferation can be improved for spent fuel transportation and storage by designing an integrated tag that uses current infrastructure for reporting and in an event; tracking can be accomplished using the Iridium satellite system. This technology is similar to GPS but with higher signal strength and penetration power, but lower accuracy. A sensor package can integrate all or some of the above depending on the transportation and storage requirements and regulations. A sensor package can be developed using off the shelf technology and applying it to each

  20. Retrieval of Aerosol Parameters from Continuous H24 Lidar-Ceilometer Measurements

    Science.gov (United States)

    Dionisi, D.; Barnaba, F.; Costabile, F.; Di Liberto, L.; Gobbi, G. P.; Wille, H.

    2016-06-01

    Ceilometer technology is increasingly applied to the monitoring and the characterization of tropospheric aerosols. In this work, a method to estimate some key aerosol parameters (extinction coefficient, surface area concentration and volume concentration) from ceilometer measurements is presented. A numerical model has been set up to derive a mean functional relationships between backscatter and the above mentioned parameters based on a large set of simulated aerosol optical properties. A good agreement was found between the modeled backscatter and extinction coefficients and the ones measured by the EARLINET Raman lidars. The developed methodology has then been applied to the measurements acquired by a prototype Polarization Lidar-Ceilometer (PLC). This PLC instrument was developed within the EC- LIFE+ project "DIAPASON" as an upgrade of the commercial, single-channel Jenoptik CHM15k system. The PLC run continuously (h24) close to Rome (Italy) for a whole year (2013-2014). Retrievals of the aerosol backscatter coefficient at 1064 nm and of the relevant aerosol properties were performed using the proposed methodology. This information, coupled to some key aerosol type identification made possible by the depolarization channel, allowed a year-round characterization of the aerosol field at this site. Examples are given to show how this technology coupled to appropriate data inversion methods is potentially useful in the operational monitoring of parameters of air quality and meteorological interest.

  1. Continuous Online Item Calibration: Parameter Recovery and Item Utilization.

    Science.gov (United States)

    Ren, Hao; van der Linden, Wim J; Diao, Qi

    2017-06-01

    Parameter recovery and item utilization were investigated for different designs for online test item calibration. The design was adaptive in a double sense: it assumed both adaptive testing of examinees from an operational pool of previously calibrated items and adaptive assignment of field-test items to the examinees. Four criteria of optimality for the assignment of the field-test items were used, each of them based on the information in the posterior distributions of the examinee's ability parameter during adaptive testing as well as the sequentially updated posterior distributions of the field-test item parameters. In addition, different stopping rules based on target values for the posterior standard deviations of the field-test parameters and the size of the calibration sample were used. The impact of each of the criteria and stopping rules on the statistical efficiency of the estimates of the field-test parameters and on the time spent by the items in the calibration procedure was investigated. Recommendations as to the practical use of the designs are given.

  2. A miniaturized transcutaneous system for continuous glucose monitoring.

    Science.gov (United States)

    Croce, Robert A; Vaddiraju, SanthiSagar; Kondo, Jun; Wang, Yan; Zuo, Liang; Zhu, Kai; Islam, Syed K; Burgess, Diane J; Papadimitrakopoulos, Fotios; Jain, Faquir C

    2013-02-01

    Implantable sensors for continuous glucose monitoring hold great potential for optimal diabetes management. This is often undermined by a variety of issues associated with: (1) negative tissue response; (2) poor sensor performance; and (3) lack of device miniaturization needed to reduce implantation trauma. Herein, we report our initial results towards constructing an implantable device that simultaneously address all three aforementioned issues. In terms of device miniaturization, a highly miniaturized CMOS (complementary metal-oxide-semiconductor) potentiostat and signal processing unit was employed (with a combined area of 0.665 mm(2)). The signal processing unit converts the current generated by a transcutaneous, Clark-type amperometric sensor to output frequency in a linear fashion. The Clark-type amperometric sensor employs stratification of five functional layers to attain a well-balanced mass transfer which in turn yields a linear sensor response from 0 to 25 mM of glucose concentration, well beyond the physiologically observed (2 to 22 mM) range. In addition, it is coated with a thick polyvinyl alcohol (PVA) hydrogel with embedded poly(lactic-co-glycolic acid) (PLGA) microspheres intended to provide continuous, localized delivery of dexamethasone to suppress inflammation and fibrosis. In vivo evaluation in rat model has shown that the transcutaneous sensor system reproducibly tracks repeated glycemic events. Clarke's error grid analysis on the as-obtained glycemic data has indicated that all of the measured glucose readings fell in the desired Zones A & B and none fell in the erroneous Zones C, D and E. Such reproducible operation of the transcutaneous sensor system, together with low power (140 μW) consumption and capability for current-to-frequency conversion renders this a versatile platform for continuous glucose monitoring and other biomedical sensing devices.

  3. Flexible carbon nanotube nanocomposite sensor for multiple physiological parameter monitoring

    KAUST Repository

    Nag, Anindya

    2016-10-16

    The paper presents the design, development, and fabrication of a flexible and wearable sensor based on carbon nanotube nanocomposite for monitoring specific physiological parameters. Polydimethylsiloxane (PDMS) was used as the substrate with a thin layer of a nanocomposite comprising functionalized multi-walled carbon nanotubes (MWCNTs) and PDMS as electrodes. The sensor patch functionalized on strain-sensitive capacitive sensing from interdigitated electrodes which were patterned with a laser on the nanocomposite layer. The thickness of the electrode layer was optimized regarding strain and conductivity. The sensor patch was connected to a monitoring device from one end and attached to the body on the other for examining purposes. Experimental results show the capability of the sensor patch used to detect respiration and limb movements. This work is a stepping stone of the sensing system to be developed for multiple physiological parameters.

  4. Wearable wireless multi-parameter sensor module for physiological monitoring.

    Science.gov (United States)

    Liverud, Anders E; Vedum, Jon; Fleurey, Franck; Seeberg, Trine M

    2012-01-01

    Advances in low power technology have given new possibilities for continuous physiological monitoring in several domains such as health care with disease prevention and quality of care services and workers in harsh environment. A miniaturized, multifunctional sensor module that transmits sensor data wirelessly using Bluetooth Smart technology has been developed. The wireless communication link is influenced by factors like antenna orientation, reflections, interference and noise. Test results for signal strength measurements for the wireless transmission in various setups are given and discussed.

  5. A new system for continuous and remote monitoring of patients receiving home mechanical ventilation

    Science.gov (United States)

    Battista, L.

    2016-09-01

    Home mechanical ventilation is the treatment of patients with respiratory failure or insufficiency by means of a mechanical ventilator at a patient's home. In order to allow remote patient monitoring, several tele-monitoring systems have been introduced in the last few years. However, most of them usually do not allow real-time services, as they have their own proprietary communication protocol implemented and some ventilation parameters are not always measured. Moreover, they monitor only some breaths during the whole day, despite the fact that a patient's respiratory state may change continuously during the day. In order to reduce the above drawbacks, this work reports the development of a novel remote monitoring system for long-term, home-based ventilation therapy; the proposed system allows for continuous monitoring of the main physical quantities involved during home-care ventilation (e.g., differential pressure, volume, and air flow rate) and is developed in order to allow observations of different remote therapy units located in different places of a city, region, or country. The developed remote patient monitoring system is able to detect various clinical events (e.g., events of tube disconnection and sleep apnea events) and has been successfully tested by means of experimental tests carried out with pulmonary ventilators typically used to support sick patients.

  6. Analysis of Continuous Glucose Monitoring in Pregnant Women With Diabetes

    DEFF Research Database (Denmark)

    Law, Graham R; Ellison, George T H; Secher, Anna L;

    2015-01-01

    ) and type 2 diabetes (n = 28) who used repeated CGM during pregnancy were recruited from secondary care multidisciplinary obstetric clinics for diabetes in the U.K. and Denmark. LGA was defined as birth weight ≥90th percentile adjusted for sex and gestational age. RESULTS: A total of 54 of 117 (46%) women......OBJECTIVE: Continuous glucose monitoring (CGM) is increasingly used to assess glucose control in diabetes. The objective was to examine how analysis of glucose data might improve our understanding of the role temporal glucose variation has on large-for-gestational-age (LGA) infants born to women...... with diabetes. RESEARCH DESIGN AND METHODS: Functional data analysis (FDA) was applied to 1.68 million glucose measurements from 759 measurement episodes, obtained from two previously published randomized controlled trials of CGM in pregnant women with diabetes. A total of 117 women with type 1 diabetes (n = 89...

  7. Lab-on-a-chip technology for continuous glucose monitoring.

    Science.gov (United States)

    Gravesen, Peter; Raaby Poulsen, Kristian; Dirac, Holger

    2007-05-01

    The demand for continuous glucose monitoring systems is greater than ever. The microelectromechanical systems (MEMS) approach has the advantage of being relatively easy to upscale to a commercial level; the preferred MEMS technique would be to run several detectors at once and, through the improved statistics, get a both more accurate and more reliable device than is currently available. Lab-on-a-chip technology may be seen as a further development of MEMS technology for analytical sensors. Lab-on-a-chip systems may be used to obtain improvements on several important characteristics of a sensor system: remove or decrease cross-sensitivity, improve sensor stability, improve accuracy, and/or improve response time compared to similar laboratory-equipment methods.

  8. Noninvasive continuous arterial blood pressure monitoring with Nexfin®.

    Science.gov (United States)

    Martina, Jerson R; Westerhof, Berend E; van Goudoever, Jeroen; de Beaumont, Edouard M F H; Truijen, Jasper; Kim, Yu-Sok; Immink, Rogier V; Jöbsis, Dorothea A; Hollmann, Markus W; Lahpor, Jaap R; de Mol, Bas A J M; van Lieshout, Johannes J

    2012-05-01

    If invasive measurement of arterial blood pressure is not warranted, finger cuff technology can provide continuous and noninvasive monitoring. Finger and radial artery pressures differ; Nexfin® (BMEYE, Amsterdam, The Netherlands) measures finger arterial pressure and uses physiologic reconstruction methodologies to obtain values comparable to invasive pressures. Intra-arterial pressure (IAP) and noninvasive Nexfin arterial pressure (NAP) were measured in cardiothoracic surgery patients, because invasive pressures are available. NAP-IAP differences were analyzed during 30 min. Tracking was quantified by within-subject precision (SD of individual NAP-IAP differences) and correlation coefficients. The ranges of pressure change were quantified by within-subject variability (SD of individual averages of NAP and IAP). Accuracy and precision were expressed as group average ± SD of the differences and considered acceptable when smaller than 5 ± 8 mmHg, the Association for the Advancement of Medical Instrumentation criteria. NAP and IAP were obtained in 50 (34-83 yr, 40 men) patients. For systolic, diastolic, mean arterial, and pulse pressure, median (25-75 percentiles) correlation coefficients were 0.96 (0.91-0.98), 0.93 (0.87-0.96), 0.96 (0.90-0.97), and 0.94 (0.85-0.98), respectively. Within-subject precisions were 4 ± 2, 3 ± 1, 3 ± 2, and 3 ± 2 mmHg, and within-subject variations 13 ± 6, 6 ± 3, 9 ± 4, and 7 ± 4 mmHg, indicating precision over a wide range of pressures. Group average ± SD of the NAP-IAP differences were -1 ± 7, 3 ± 6, 2 ± 6, and -3 ± 4 mmHg, meeting criteria. Differences were not related to mean arterial pressure or heart rate. Arterial blood pressure can be measured noninvasively and continuously using physiologic pressure reconstruction. Changes in pressure can be followed and values are comparable to invasive monitoring.

  9. In situ optical absorption mercury continuous emission monitor.

    Science.gov (United States)

    Thiebaud, Jérôme; Thomson, Murray J; Mani, Reza; Morrow, William H; Morris, Eric A; Jia, Charles Q

    2009-12-15

    This paper reports the development of an in situ continuous emission monitor (CEM) for measuring elemental mercury (Hg(0)) concentration in the exhaust stream of coal-fired power plants. The instrument is based on the ultraviolet atomic absorption of a mercury lamp emission line by elemental mercury and a light-emitting diode (LED) background correction system. This approach allows an in situ measurement since the absorption of other species such as SO(2) can be removed to monitor the Hg(0) contribution only. Proof of concept was established through a laboratory-based investigation, and a limit of detection, [Hg(0)](min), of 2 microg/m(3) was measured for a 1-min averaged sample and an absorption path length of 49 cm. [Hg(0)](min) is anticipated to be better than 0.2 microg/m(3) across a 7 m diameter stack. Finally, the apparatus was field-tested in a 230 MW coal-fired power plant. The operability of the measurement in real conditions was demonstrated, leading to the first Hg(0) concentration values recorded by the in situ CEM. Comparison with an accepted standard method is required for validation.

  10. Usefulness of continuous electrocardiographic monitoring for atrial fibrillation.

    Science.gov (United States)

    Camm, A John; Corbucci, Giorgio; Padeletti, Luigi

    2012-07-15

    The problem of early recognition of atrial fibrillation (AF) is greatly aggravated by the often silent nature of the rhythm disturbance. In about 1/3 of patients with this arrhythmia, patients are not aware of the so-called asymptomatic AF. In the past 15 years, the diagnostic data provided by implanted pacemakers and defibrillators have dramatically increased knowledge about silent AF. The unreliability of symptoms to estimate AF burden and to identify patients with and without AF has been pointed out not only by pacemaker trials but also in patients without implanted devices. The technology for continuous monitoring of AF has been largely validated. It is a powerful tool to detect silent paroxysmal AF in patients without previously documented arrhythmic episodes, such as those with cryptogenic stroke or other risk factors. Early diagnosis triggers earlier treatment for primary or secondary stroke prevention. Today, new devices are also available for pure electrocardiographic monitoring, implanted subcutaneously using a minimally invasive technique. In conclusion, this recent and promising technology adds relevant clinical and scientific information to improve risk stratification for stroke and may play an important role in testing and tailoring the therapies for rhythm and rate control.

  11. Continuous monitoring of Hawaiian volcanoes with thermal cameras

    Science.gov (United States)

    Patrick, Matthew R.; Orr, Tim R.; Antolik, Loren; Lee, Robert Lopaka; Kamibayashi, Kevan P.

    2014-01-01

    Continuously operating thermal cameras are becoming more common around the world for volcano monitoring, and offer distinct advantages over conventional visual webcams for observing volcanic activity. Thermal cameras can sometimes “see” through volcanic fume that obscures views to visual webcams and the naked eye, and often provide a much clearer view of the extent of high temperature areas and activity levels. We describe a thermal camera network recently installed by the Hawaiian Volcano Observatory to monitor Kīlauea’s summit and east rift zone eruptions (at Halema‘uma‘u and Pu‘u ‘Ō‘ō craters, respectively) and to keep watch on Mauna Loa’s summit caldera. The cameras are long-wave, temperature-calibrated models protected in custom enclosures, and often positioned on crater rims close to active vents. Images are transmitted back to the observatory in real-time, and numerous Matlab scripts manage the data and provide automated analyses and alarms. The cameras have greatly improved HVO’s observations of surface eruptive activity, which includes highly dynamic lava lake activity at Halema‘uma‘u, major disruptions to Pu‘u ‘Ō‘ō crater and several fissure eruptions.

  12. Stability and optimal parameters for continuous feedback chaos control.

    Science.gov (United States)

    Kouomou, Y Chembo; Woafo, P

    2002-09-01

    We investigate the conditions under which an optimal continuous feedback control can be achieved. Chaotic oscillations in the single-well Duffing model, with either a positive or a negative nonlinear stiffness term, are tuned to their related Ritz approximation. The Floquet theory enables the stability analysis of the control. Critical values of the feedback control coefficient fulfilling the optimization criteria are derived. The influence of the chosen target orbit, of the feedback coefficient, and of the onset time of control on its duration is discussed. The analytic approach is confirmed by numerical simulations.

  13. [Research on signal processing for water quality monitoring based on continuous spectral analysis].

    Science.gov (United States)

    Wei, Kang-lin; Chen, Ming; Wen, Zhi-yu; Xie, Yin-ke

    2014-12-01

    Based on continuous spectrum analysis, the mathematical model for spectrum signal was established. And the spectrum signal's systematic error processing method based on the invariance of the ratio of the light intensities at any two wavelengths in the range of continuous spectrum was put forward. Combined with wavelet multi-resolution filtering noise processing techniques, the background interference processing method was established based on the spectral characteristics of the measured water quality parameter. These signal processing methods were applied to our independently developed multi-parameter water quality monitoring instrument to on-line measure COD (chemical oxygen demand), six valence chromium and anionic surfactant in the normative and actual environmental water samples, and the monitoring instrument had good repeatability (10%) and high accuracy (±10%) to meet the technical requirements of national environmental protection standards, which was verified by the contrast experiment with China national standard analysis method for determination of the three water quality parameter. The results showed that the researched signal processing methods were able to effectively reduce the spectrum signal's systematic error and the interference from noise and background, which was very important to improve the water quality monitoring instrument's technical function.

  14. Parameters monitoring and control for flueric actuators testing syste

    Directory of Open Access Journals (Sweden)

    Tiberiu Adrian SALAORU

    2014-04-01

    Full Text Available A wide range of air supply parameters is needed for the flueric actuators testing in order to find their optimum working regime. A system for conditioning these parameters, namely pressure, temperature, mass and volume flow rate has been built for this purpose. The measured values are continuously stored on the PC hard drive and are checked automatically for keeping them in the normal operating range. In case any of them are going out of this range, this system warns the operator and performs automatic actions for limiting or partially or totally shutting down the system.

  15. Microfluidic solutions enabling continuous processing and monitoring of biological samples: A review.

    Science.gov (United States)

    Karle, Marc; Vashist, Sandeep Kumar; Zengerle, Roland; von Stetten, Felix

    2016-07-27

    The last decade has witnessed tremendous advances in employing microfluidic solutions enabling Continuous Processing and Monitoring of Biological Samples (CPMBS), which is an essential requirement for the control of bio-processes. The microfluidic systems are superior to the traditional inline sensors due to their ability to implement complex analytical procedures, such as multi-step sample preparation, and enabling the online measurement of parameters. This manuscript provides a backgound review of microfluidic approaches employing laminar flow, hydrodynamic separation, acoustophoresis, electrophoresis, dielectrophoresis, magnetophoresis and segmented flow for the continuous processing and monitoring of biological samples. The principles, advantages and limitations of each microfluidic approach are described along with its potential applications. The challenges in the field and the future directions are also provided.

  16. Continuous monitoring of Hawaiian volcanoes using thermal cameras

    Science.gov (United States)

    Patrick, M. R.; Orr, T. R.; Antolik, L.; Lee, R.; Kamibayashi, K.

    2012-12-01

    Thermal cameras are becoming more common at volcanoes around the world, and have become a powerful tool for observing volcanic activity. Fixed, continuously recording thermal cameras have been installed by the Hawaiian Volcano Observatory in the last two years at four locations on Kilauea Volcano to better monitor its two ongoing eruptions. The summit eruption, which began in March 2008, hosts an active lava lake deep within a fume-filled vent crater. A thermal camera perched on the rim of Halema`uma`u Crater, acquiring an image every five seconds, has now captured about two years of sustained lava lake activity, including frequent lava level fluctuations, small explosions , and several draining events. This thermal camera has been able to "see" through the thick fume in the crater, providing truly 24/7 monitoring that would not be possible with normal webcams. The east rift zone eruption, which began in 1983, has chiefly consisted of effusion through lava tubes onto the surface, but over the past two years has been interrupted by an intrusion, lava fountaining, crater collapse, and perched lava lake growth and draining. The three thermal cameras on the east rift zone, all on Pu`u `O`o cone and acquiring an image every several minutes, have captured many of these changes and are providing an improved means for alerting observatory staff of new activity. Plans are underway to install a thermal camera at the summit of Mauna Loa to monitor and alert to any future changes there. Thermal cameras are more difficult to install, and image acquisition and processing are more complicated than with visual webcams. Our system is based in part on the successful thermal camera installations by Italian volcanologists on Stromboli and Vulcano. Equipment includes custom enclosures with IR transmissive windows, power, and telemetry. Data acquisition is based on ActiveX controls, and data management is done using automated Matlab scripts. Higher-level data processing, also done with

  17. 40 CFR Table 3 of Subpart Aaaa to... - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 3 Table 3 of Subpart AAAA to Part 60 Protection of Environment... Continuous Emission Monitoring Systems (CEMS) For the following continuous emission monitoring systems...

  18. Developing Dynamic Digital Image Techniques with Continuous Parameters to Detect Structural Damage

    Directory of Open Access Journals (Sweden)

    Ming-Hsiang Shih

    2013-01-01

    Full Text Available Several earthquakes with strong magnitude occurred globally at various locations, especially the unforgettable tsunami disaster caused by the earthquake in Indonesia and Japan. If the characteristics of structures can be well understood to implement new technology, the damages caused by most natural disasters can be significantly alleviated. In this research, dynamic digital image correlation method for using continuous parameter is applied for developing a low-cost digital image correlation coefficient method with advanced digital cameras and high-speed computers. The experimental study using cantilever test object with defect control confirms that the vibration mode calculated using this proposed method can highly express the defect locations. This proposed method combined with the sensitivity of Inter-Story Drift Mode Shape, IDMS, can also reveal the damage degree of damage structure. These test and analysis results indicate that this proposed method is high enough for applying to achieve the object of real-time online monitoring of structure.

  19. 1997 Performance Testing of Multi-Metal Continuous Emissions Monitors

    Energy Technology Data Exchange (ETDEWEB)

    Sky +, Inc.

    1998-09-01

    Five prototype and two commercially available multi-metals continuous emissions monitors (CEMs) were tested in September 1997 at the Rotary Kiln Incinerator Simulator facility at the EPA National Risk Management Research Laboratory, Research Triangle Park, North Carolina. The seven CEMs were tested side by side in a long section of duct following the secondary combustion chamber of the RKIS. Two different concentrations of six toxic metals were introduced into the incinerator-approximately 15 and 75 µg/dscm of arsenic, beryllium, cadmium, chromium, lead, and mercury (We also tested for antimony but we are not reporting on it here because EPA recently dropped antimony from the list of metals addressed by the draft MACT rule). These concentrations were chosen to be close to emission standards in the draft MACT rule and the estimated Method Detection Limit (MDL) required of a CEM for regulatory compliance purposes. Results from this test show that no CEMs currently meet the performance specifications in the EPA draft MACT rule for hazardous waste incinerators. Only one of the CEMs tested was able to measure all six metals at the concentrations tested. Even so, the relative accuracy of this CEM varied between 35% and 100%, not 20% or less as required in the EPA performance specification. As a result, we conclude that no CEM is ready for long-term performance validation for compliance monitoring applications. Because sampling and measuring Hg is a recurring problem for multi-metal CEMs as well as Hg CEMs, we recommended that developers participate in a 1998 DOE-sponsored workshop to solve these and other common CEM measurement issues.

  20. Coral Reef Monitoring: From Cytological Parameters to Community Indices

    Directory of Open Access Journals (Sweden)

    Ofer Ben-Tzvi

    2011-01-01

    Full Text Available Sound-ecosystem-based management of coral reefs is largely based on indicators of reef health state. Currently there are various ecological parameters that serve as reef state indices; however, their practical implications are under debate. In the present study we examine an alternative parameter, the deterioration index (DI, which does not purport to replace the traditional indices but can provide a reliable, stand-alone indication of reef state. Patterns of cytological indices, which are considered as reliable indicators of environmental stressors, have been compared to ten selected reef community indices. The DI showed the highest correlations among community indices to the cytological indices in artificial reefs and high correlation in natural reefs as well. Our results suggest that in cases of lacking adequate monitoring abilities where a full set of community indices cannot be obtained, the DI can serve in many cases as the preferred, stand-alone indicator of coral reef state.

  1. Educating Families on Real Time Continuous Glucose Monitoring

    Science.gov (United States)

    Messer, Laurel; Ruedy, Katrina; Xing, Dongyuan; Coffey, Julie; Englert, Kimberly; Caswell, Kimberly; Ives, Brett

    2013-01-01

    Purpose The purpose of this article is to describe the process of educating families and children with type 1 diabetes on real time continuous glucose monitoring (RT-CGM) and to note the similarities and differences of training patients using continuous subcutaneous insulin infusion (CSII) versus multiple daily injections (MDI). Methods A total of 30 CSII participants and 27 MDI participants were educated using the Navigator RT-CGM in a clinical trial. Time spent with families for visits and calls was tracked and compared between patient groups. The Diabetes Research in Children Network (DirecNet) educators were surveyed to assess the most crucial, time intensive, and difficult educational concepts related to CGM. Results Of the 27 MDI families, an average of 9.6 hours was spent on protocol-prescribed visits and calls (not measured in CSII) and 2 hours on participant-initiated contacts over 3 months. MDI families required an average of 5.4 more phone contacts over 3 months than CSII families. According to the DirecNet educators, lag time and calibrations were the most crucial teaching concepts for successful RT-CGM use. The most time was spent on teaching technical aspects, troubleshooting, and insulin dosing. The most unanticipated difficulties were skin problems including irritation and the sensor not adhering well. Conclusion Educators who teach RT-CGM should emphasize lag time and calibration techniques, technical device training, and sensor insertion. Follow-up focus should include insulin dosing adjustments and skin issues. The time and effort required to introduce RT-CGM provided an opportunity for the diabetes educators to reemphasize good diabetes care practices and promote self-awareness and autonomy to patients and families. PMID:19244568

  2. Monitor of dynamic parameters in real time; Monitor de parametros dinamicos en tiempo real

    Energy Technology Data Exchange (ETDEWEB)

    Rojas S, A.S.; Ruiz E, J.A. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)

    2008-07-01

    In the complex physical systems exist parameters that are necessary for monitoring in real time. In the nuclear industry, particularly in a reactor this surveillance is important, where the times of the reactions are almost instantaneous. Although many of these parameters are monitored, given the advance of the computer systems the monitoring could either be enlarged direct or indirect of other parameters. The analysis of the neutron noise in the nuclear reactors, plays an important role, the noise signal it contains information about the operation conditions of a system, when analyzing it with analysis methodologies of analogical signals to provide important information for the early detection of possible flaws and to indicate the permissible operation levels. To show the characteristics of the operation of the system of Monitoring of Dynamic Parameters in Real Time, oscillations of neutron noise of the TRIGA Mark III of the ININ were analyzed, these were caused with the control bar to a power of 10 Watts, the oscillations were carried out to a frequency of 1Hz, signal of low frequency. In this work a virtual instrument that allows by means of the spectral analysis method in frequency point by point is presented, to indicate in real time periodic variations that could be presented in the neutron noise signal, visualizing in advance the dynamic behavior of the system or nuclear plant. Another of the tests of the monitoring system presented is that of the oscillatory event happened in the reactor of Laguna Verde Nucleo electric Central, would be convenient to have an instrument of surveillance for monitoring through the neutron noise signal the behavior of some important parameter to predict and to indicate in an immediate way an abnormal condition in the reactor operation or in the plant system. These parameters can be the power, the recirculation water flow, etc. The monitor is based on a personal computer (PC), a data acquisition card (ADC) and a computer program

  3. Performance testing of multi-metal continuous emissions monitors

    Energy Technology Data Exchange (ETDEWEB)

    Haas, W.J. [Ames Lab., IA (United States); French, N.B. [Sky+, Inc. (United States); Brown, C.H. [Oak Ridge National Lab., TN (United States); Burns, D.B. [Westinghouse Savannah River Co., Aiken, SC (United States); Lemieux, P.M.; Ryan, J.V. [National Risk Management Research Lab., Research Triangle Park, NC (United States); Priebe, S.J. [Idaho National Engineering and Environmental Lab., Idaho Falls, ID (United States); Waterland, L.R. [Acurex Environmental Corp. (United States)

    1997-11-17

    Three prototype multi-metals continuous emissions monitors (CEMs) were tested in April 1996 at the Rotary Kiln Incinerator Simulator facility at the US Environmental Protection Agency (EPA) National Risk Management Research Laboratory, Research Triangle Park, North Carolina. The CEM instruments were: Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES); Laser Induced Breakdown Spectrometry-Atomic Emission Spectroscopy (LIBS); and Laser Spark Spectrometry, another LIBS instrument. The three CEMs were tested simultaneously during test periods in which low, medium, and high concentration levels of seven toxic metals -- antimony, arsenic, beryllium, cadmium, chromium, lead, and mercury -- were maintained under carefully controlled conditions. Two methods were used to introduce the test metals into the flue gas: (1) solution atomization, introducing metal-containing aerosol directly into the secondary combustion burner, and (2) injection of fly ash particulates. The testing addressed four measures of CEM performance: relative accuracy (RA), calibration drift, zero drift, and response time. These were accomplished by comparing the toxic metal analyte concentrations reported by the CEMs to the concentrations measured using the EPA reference method (RM) for the same analytes. Overall, the test results showed the prototype nature of the test CEMs and the clear need for further development. None of the CEMs tested consistently achieved RA values of 20% or less as required by the EPA draft performance specification. Instrument size reduction and automation will also likely need additional attention before multi-metal CEMs systems become commercially available for service as envisioned by regulators and citizens.

  4. An Implantable RFID Sensor Tag toward Continuous Glucose Monitoring.

    Science.gov (United States)

    Xiao, Zhibin; Tan, Xi; Chen, Xianliang; Chen, Sizheng; Zhang, Zijian; Zhang, Hualei; Wang, Junyu; Huang, Yue; Zhang, Peng; Zheng, Lirong; Min, Hao

    2015-05-01

    This paper presents a wirelessly powered implantable electrochemical sensor tag for continuous blood glucose monitoring. The system is remotely powered by a 13.56-MHz inductive link and utilizes an ISO 15693 radio frequency identification (RFID) standard for communication. This paper provides reliable and accurate measurement for changing glucose level. The sensor tag employs a long-term glucose sensor, a winding ferrite antenna, an RFID front-end, a potentiostat, a 10-bit sigma-delta analog to digital converter, an on-chip temperature sensor, and a digital baseband for protocol processing and control. A high-frequency external reader is used to power, command, and configure the sensor tag. The only off-chip support circuitry required is a tuned antenna and a glucose microsensor. The integrated chip fabricated in SMIC 0.13-μm CMOS process occupies an area of 1.2 mm ×2 mm and consumes 50 μW. The power sensitivity of the whole system is -4 dBm. The sensor tag achieves a measured glucose range of 0-30 mM with a sensitivity of 0.75 nA/mM.

  5. Instrumentation of Lysimeter Experiments and Monitoring of Soil Parameters

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, T.; Tallos, A.; Millan, R.; Vera, R.; Recreo, F.

    2004-07-01

    This study forms part of the project Mercurio and Recuperation de Terrenos Afectados por Mercurio Ambiental (RETAMA), which determines the behaviour of mercury in the soil-plant system within the area of Almaden. The objective of this work is to instrument lysimeters with a set of electronic sensors to monitor physical and chemical soil parameters (moisture content, soil temperature, soil water matrix potential. Eh and pH) over a period of a complete vegetation cycle for selected crops. Physical and chemical soil analyses have been carried out on samples two soil profiles marking the extreme perimeter where the lysimeters were extracted. The monitoring data obtained every half hour show that the physicochemical conditions of the soils in the lysimeter can be correlated with the type of cultivation in the lysimeters. The results for parameters such as soil water matrix potential and the soil temperature reflect the diurnal changes; and fluctuations of the Eh can be related to the biological activities in the soils and are within oxid and suboxic conditions. Slight fluctuations have been observed for the pH and constant volumetric moisture content is maintained during the period of no hydric stress. (Author) 16 refs.

  6. Therapeutic Drug Monitoring of Continuous Infusion Doripenem in a Pediatric Patient on Continuous Renal Replacement Therapy.

    Science.gov (United States)

    Cies, Jeffrey J; Moore, Wayne S; Conley, Susan B; Shea, Paul; Enache, Adela; Chopra, Arun

    2017-01-01

    An 11-year-old African American male with severe combined immunodeficiency variant, non-cystic fibrosis bronchiectasis, pancreatic insufficiency, chronic mycobacterium avium-intracellulare infection, chronic sinusitis, and malnutrition presented with a 1-week history of fevers. He subsequently developed respiratory decompensation and cefepime was discontinued and doripenem was initiated. Doripenem was the carbapenem used due to a national shortage of meropenem. By day 7 the patient (24.7 kg) had a positive fluid balance of 6925 mL (28% FO), and on days 7 into 8 developed acute kidney injury evidenced by an elevated serum creatinine of 0.68 mg/dL, an increase from the baseline of 0.28 mg/dL. On day 9, the patient was initiated on continuous renal replacement therapy (CRRT) and the doripenem dosing was changed to a continuous infusion of 2.5 mg/kg/hr (60 mg/kg/day). Approximately 12.5 hours after the start of the doripenem a serum concentration was obtained, which was 4.01 mg/L corresponding to a clearance of 10.5 mL/min/kg. The pediatric dosing and pharmacokinetic data available for doripenem suggest a clearance estimate of 4.4 to 4.8 mL/min/kg, and the adult clearance estimate is 2.4 to 3.78 mL/min/kg. The calculated clearance in our patient of 10.5 mL/min/kg is over double the highest clearance estimate in the pediatric literature. This case demonstrates that doripenem clearance is significantly increased with CRRT in comparison with the published pediatric and adult data. An appropriate pharmacodynamic outcome (time that free drug concentration > minimum inhibitory concentration) can be achieved by continuous infusion doripenem with concurrent therapeutic drug monitoring.

  7. Optical sensor technology for a noninvasive continuous monitoring of blood components

    Science.gov (United States)

    Kraitl, Jens; Timm, Ulrich; Lewis, Elfed; Ewald, Hartmut

    2010-02-01

    NIR-spectroscopy and Photoplethysmography (PPG) is used for a measurement of blood components. The absorptioncoefficient of blood differs at different wavelengths. This fact is used to calculate the optical absorbability characteristics of blood which is yielding information about blood components like hemoglobin (Hb), carboxyhemoglobin (CoHb) and arterial oxygen saturation (SpO2). The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. Hemoglobin is the main component of red blood cells. The primary function of Hb is the transport of oxygen from the lungs to the tissue and carbon dioxide back to the lungs. The Hb concentration in human blood is an important parameter in evaluating the physiological status of an individual and an essential parameter in every blood count. Currently, invasive methods are used to measure the Hb concentration, whereby blood is taken from the patient and subsequently analyzed. Apart from the discomfort of drawing blood samples, an added disadvantage of this method is the delay between the blood collection and its analysis, which does not allow real time patient monitoring in critical situations. A noninvasive method allows pain free continuous on-line patient monitoring with minimum risk of infection and facilitates real time data monitoring allowing immediate clinical reaction to the measured data.

  8. Continuous monitoring of water flow and solute transport using vadose zone monitoring technology

    Science.gov (United States)

    Dahan, O.

    2009-04-01

    Groundwater contamination is usually attributed to pollution events that initiate on land surface. These may be related to various sources such as industrial, urban or agricultural, and may appear as point or non point sources, through a single accidental event or a continuous pollution process. In all cases, groundwater pollution is a consequence of pollutant transport processes that take place in the vadose zone above the water table. Attempts to control pollution events and prevent groundwater contamination usually involve groundwater monitoring programs. This, however, can not provide any protection against contamination since pollution identification in groundwater is clear evidence that the groundwater is already polluted and contaminants have already traversed the entire vadose zone. Accordingly, an efficient monitoring program that aims at providing information that may prevent groundwater pollution has to include vadose-zone monitoring systems. Such system should provide real-time information on the hydrological and chemical properties of the percolating water and serve as an early warning system capable of detecting pollution events in their early stages before arrival of contaminants to groundwater. Recently, a vadose-zone monitoring system (VMS) was developed to allow continuous monitoring of the hydrological and chemical properties of percolating water in the deep vadose zone. The VMS includes flexible time-domain reflectometry (FTDR) probes for continuous tracking of water content profiles, and vadose-zone sampling ports (VSPs) for frequent sampling of the deep vadose pore water at multiple depths. The monitoring probes and sampling ports are installed through uncased slanted boreholes using a flexible sleeve that allows attachment of the monitoring devices to the borehole walls while achieving good contact between the sensors and the undisturbed sediment column. The system has been successfully implemented in several studies on water flow and

  9. Continuous Non-Invasive Arterial Pressure Technique Improves Patient Monitoring during Interventional Endoscopy

    Directory of Open Access Journals (Sweden)

    Sylvia Siebig, Felix Rockmann, Karl Sabel, Ina Zuber-Jerger, Christine Dierkes, Tanja Brünnler, Christian E. Wrede

    2009-01-01

    Full Text Available Introduction: Close monitoring of arterial blood pressure (BP is a central part of cardiovascular surveillance of patients at risk for hypotension. Therefore, patients undergoing diagnostic and therapeutic procedures with the use of sedating agents are monitored by discontinuous non-invasive BP measurement (NIBP. Continuous non-invasive BP monitoring based on vascular unloading technique (CNAP®, CN Systems, Graz may improve patient safety in those settings. We investigated if this new technique improved monitoring of patients undergoing interventional endoscopy. Methods: 40 patients undergoing interventional endoscopy between April and December 2007 were prospectively studied with CNAP® in addition to standard monitoring (NIBP, ECG and oxygen saturation. All monitoring values were extracted from the surveillance network at one-second intervals, and clinical parameters were documented. The variance of CNAP® values were calculated for every interval between two NIBP measurements. Results: 2660 minutes of monitoring were recorded (mean 60.1±34.4 min/patient. All patients were analgosedated with midazolam and pethidine, and 24/40 had propofol infusion (mean 90.9±70.3 mg. The mean arterial pressure for CNAP® was 102.4±21.2 mmHg and 106.8±24.8 mmHg for NIBP. Based on the first NIBP value in an interval between two NIBP measurements, BP values determined by CNAP® showed a maximum increase of 30.8±21.7% and a maximum decrease of 22.4±28.3% (mean of all intervals. Discussion: Conventional intermittent blood pressure monitoring of patients receiving sedating agents failed to detect fast changes in BP. The new technique CNAP® improved the detection of rapid BP changes, and may contribute to a better patient safety for those undergoing interventional procedures.

  10. 77 FR 13997 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-03-08

    ... AGENCY 40 CFR Part 60 RIN 2060-AH23 Quality Assurance Requirements for Continuous Opacity Monitoring... rule titled, ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary....regulations.gov or in hard copy at the Procedure 3--Quality Assurance Requirements for Continuous Opacity...

  11. Monitoring the Dead Sea Region by Multi-Parameter Stations

    Science.gov (United States)

    Mohsen, A.; Weber, M. H.; Kottmeier, C.; Asch, G.

    2015-12-01

    The Dead Sea Region is an exceptional ecosystem whose seismic activity has influenced all facets of the development, from ground water availability to human evolution. Israelis, Palestinians and Jordanians living in the Dead Sea region are exposed to severe earthquake hazard. Repeatedly large earthquakes (e.g. 1927, magnitude 6.0; (Ambraseys, 2009)) shook the whole Dead Sea region proving that earthquake hazard knows no borders and damaging seismic events can strike anytime. Combined with the high vulnerability of cities in the region and with the enormous concentration of historical values this natural hazard results in an extreme earthquake risk. Thus, an integration of earthquake parameters at all scales (size and time) and their combination with data of infrastructure are needed with the specific aim of providing a state-of-the-art seismic hazard assessment for the Dead Sea region as well as a first quantitative estimate of vulnerability and risk. A strong motivation for our research is the lack of reliable multi-parameter ground-based geophysical information on earthquakes in the Dead Sea region. The proposed set up of a number of observatories with on-line data access will enable to derive the present-day seismicity and deformation pattern in the Dead Sea region. The first multi-parameter stations were installed in Jordan, Israel and Palestine for long-time monitoring. All partners will jointly use these locations. All stations will have an open data policy, with the Deutsches GeoForschungsZentrum (GFZ, Potsdam, Germany) providing the hard and software for real-time data transmission via satellite to Germany, where all partners can access the data via standard data protocols.

  12. Continuous monitoring of plant growth using fiber-optic interferrometric sensing

    Science.gov (United States)

    Chatterjee, Julius; Grossman, Barry G.

    2011-06-01

    Dendrometers, dendrographs and dry weight measurements have been successfully used for measurements of plant growth. These sensors have been used with Linear Variable Differential Transformer (LVDT) based data logging systems for continuous monitoring. In this paper the preliminary results for a prototype technique is presented as a proof of concept for the continuous monitoring of plant growth using an approach based on fiber-optic interferrometric sensing. The advantage of this sensing technique over the others is the ability to measure and analyze with very high sensitivities such as micron changes in dimensions allowing measurements over short time spans. The sensor was mounted on a Dracaena Sanderiana (Lucky Bamboo) shoot and the change in shoot length dimensions resulted in changes in the output signal display which is in the form of interferrometric fringes. The data acquisition is performed over a long duration using labVIEW based data logging. Filtered output of the data has been presented where an attempt has been made to relate the fringes to length changes. The sensing system is nondestructive and noninvasive and has been targeted to respond to changes in stem length due to changes in plant growth parameters. The objective is to provide a measurement system to do research in optimizing plant growth in greatly reduced time spans. This form of sensing application is also applicable for monitoring the growth of plants growing at much slower rates.

  13. Continuous dynamic monitoring of a lively footbridge for serviceability assessment and damage detection

    Science.gov (United States)

    Hu, Wei-Hua; Moutinho, Carlos; Caetano, Elsa; Magalhães, Filipe; Cunha, Álvaro

    2012-11-01

    This paper aims at analyzing the feasibility of applying a vibration based damage detection approach, based on Principal Components Analysis (PCA), to eliminate environmental effects using the large amount of high quality data continuously collected by the dynamic monitoring system of Pedro e Inês footbridge since 2007. Few works describe real data, regularly collected along several years by reliable continuous dynamic monitoring systems in bridge structures. One main contribution is to show a large difference between making academic research based on numerical simulations or limited experimental samples, and making validity tests of innovative procedures using large high quality databases collected in real structures. The monitoring system, installed with the only initial objective of checking the efficiency of vibration control devices used to mitigate lateral and vertical vibrations, was therefore further developed for research purposes by implementing LabVIEW based automated signal processing and output-only modal identification routines, that enabled the analysis of the correlation of modal estimates with the temperature and the vibration level, as well as the automatic tracking of modal parameters along several years. With the final purpose of detecting potential structural damage at an early stage, the Principal Components Analysis (PCA) was employed to effectively eliminate temperature effects, whereas Novelty Analysis on the residual errors of the PCA model was used to provide a statistical indication of damage. The efficiency of this vibration based damage detection approach was verified using 3 years of measurements at Pedro e Inês footbridge under operational conditions and simulating several realistic damage scenarios affecting the boundary conditions. It is demonstrated that such a dynamic monitoring system, apart from providing relevant instantaneous dynamic information, working as an alert system associated to the verification of vibration

  14. A continuous glucose monitoring device by graphene modified electrochemical sensor in microfluidic system.

    Science.gov (United States)

    Pu, Zhihua; Zou, Chongwei; Wang, Ridong; Lai, Xiaochen; Yu, Haixia; Xu, Kexin; Li, Dachao

    2016-01-01

    This paper presents a continuous glucose monitoring microsystem consisting of a three-electrode electrochemical sensor integrated into a microfluidic chip. The microfluidic chip, which was used to transdermally extract and collect subcutaneous interstitial fluid, was fabricated from five polydimethylsiloxane layers using micromolding techniques. The electrochemical sensor was integrated into the chip for continuous detection of glucose. Specifically, a single-layer graphene and gold nanoparticles (AuNPs) were decorated onto the working electrode (WE) of the sensor to construct a composite nanostructured surface and improve the resolution of the glucose measurements. Graphene was transferred onto the WE surface to improve the electroactive nature of the electrode to enable measurements of low levels of glucose. The AuNPs were directly electrodeposited onto the graphene layer to improve the electron transfer rate from the activity center of the enzyme to the electrode to enhance the sensitivity of the sensor. Glucose oxidase (GOx) was immobilized onto the composite nanostructured surface to specifically detect glucose. The factors required for AuNPs deposition and GOx immobilization were also investigated, and the optimized parameters were obtained. The experimental results displayed that the proposed sensor could precisely measure glucose in the linear range from 0 to 162 mg/dl with a detection limit of 1.44 mg/dl (S/N = 3). The proposed sensor exhibited the potential to detect hypoglycemia which is still a major challenge for continuous glucose monitoring in clinics. Unlike implantable glucose sensors, the wearable device enabled external continuous monitoring of glucose without interference from foreign body reaction and bioelectricity.

  15. Variability of multifractal parameters in an urban precipitation monitoring network

    Science.gov (United States)

    Licznar, Paweł; De Michele, Carlo; Dżugaj, Dagmara; Niesobska, Maria

    2014-05-01

    Precipitation especially over urban areas is considered a highly non-linear process, with wide variability over a broad range of temporal and spatial scales. Despite obvious limitations of rainfall gauges location at urban sites, rainfall monitoring by gauge networks is a standard solution of urban hydrology. Often urban precipitation gauge networks are formed by modern electronic gauges and connected to control units of centralized urban drainage systems. Precipitation data, recorded online through these gauge networks, are used in so called Real-Time-Control (RTC) systems for the development of optimal strategies of urban drainage outflows management. As a matter of fact, the operation of RTC systems is motivated mainly by the urge of reducing the severity of urban floods and combined sewerage overflows, but at the same time, it creates new valuable precipitation data sources. The variability of precipitation process could be achieved by investigating multifractal behavior displayed by the temporal structure of precipitation data. There are multiply scientific communications concerning multifractal properties of point-rainfall data from different worldwide locations. However, very little is known about the close variability of multifractal parameters among closely located gauges, at the distances of single kilometers. Having this in mind, here we assess the variability of multifractal parameters among gauges of the urban precipitation monitoring network in Warsaw, Poland. We base our analysis on the set of 1-minute rainfall time series recorded in the period 2008-2011 by 25 electronic weighing type gauges deployed around the city by the Municipal Water Supply and Sewerage Company in Warsaw as a part of local RTC system. The presence of scale invariance and multifractal properties in the precipitation process was investigated with spectral analysis, functional box counting method and studying the probability distributions and statistical moments of the rainfall

  16. BP Neural Network of Continuous Casting Technological Parameters and Secondary Dendrite Arm Spacing of Spring Steel

    Institute of Scientific and Technical Information of China (English)

    HANG Li-hong; WANG Ai-guo; TIAN Nai-yuan; ZHANG Wei-cun; FAN Qiao-li

    2011-01-01

    The continuous casting technological parameters have a great influence on the secondary dendrite arm spacing of the slab, which determines the segregation behavior of materials. Therefore, the identification of technological parameters of continuous casting process directly impacts the property of slab. The relationships between continuous casting technological parameters and cooling rate of slab for spring steel were built using BP neural network model, based on which, the relevant secondary dendrite arm spacing was calculated. The simulation calculation was also carried out using the industrial data. The simulation results show that compared with that of the traditional method, the absolute error of calculation result obtained with BP neural network model reduced from 0. 015 to 0. 0005, and the relative error reduced from 6, 76 % to 0.22 %. BP neural network model had a more precise accuracy in the optimization of continuous casting technological parameters.

  17. MODELLING AND PARAMETER ESTIMATION IN REACTIVE CONTINUOUS MIXTURES: THE CATALYTIC CRACKING OF ALKANES. PART I

    Directory of Open Access Journals (Sweden)

    PEIXOTO F. C.

    1999-01-01

    Full Text Available Fragmentation kinetics is employed to model a continuous reactive mixture. An explicit solution is found and experimental data on the catalytic cracking of a mixture of alkanes are used for deactivation and kinetic parameter estimation.

  18. Pervasive health monitor and analysis based on multi-parameter smart armband.

    Science.gov (United States)

    Yang Yu; Qian Wang; Jing Liu

    2015-08-01

    With the growing attention on personal health, keeping track of the health related parameters has become an important issue, which is quite useful to increase people's living quality and reduce unpredicted risks. However, conventional physical checks are discrete and transient, which is incapable for the health monitor of daily living. Dedicated to everyday physiological monitor, we have developed a multi-parameter smart armband which is able record pulse, temperature and triaxial accelerations continuously. With the wearable device and signal processing algorithm, experiments of data acquisition in the daily living have been implemented on the volunteers. The long period record of 38 hours has demonstrated its feasibility of a total record without disturbing. And both historical and cross comparisons on the parameter correlation analysis have proven the valuable health information that the armband could reveal. As an integrated sensor module, the smart armband is simple and non-obtrusive, thus opens a promising approach towards the pervasive health monitor, especially for the elder population.

  19. A New GPS System for Continuous Deformation Monitoring

    Institute of Scientific and Technical Information of China (English)

    2000-01-01

    This paper presents a multi-antenna GPS based system developed for localcontinuous deformation monitoring. Due to a large number of points that needs to be monitored,the standard approaches of using permanent GPS receiver arrays will cause high cost. Iteventually becomes the limiting factor for large-scale use of GPS in these application areas.Multi-antenna GPS system allows a number of GPS antennas to be linked to one GPS receiverby a specially designed electronic component, i.e. the so-called GPS multi-antenna switch(GMS), The receiver takes data sequentially from each of the antennas attached to thereceiver. A distinctive advantage of the approach is that one GPS receiver can be used tomonitor more than one point. The cost per monitored point (i. e. the expenses of hardware)istherefore significantly reduced.

  20. Impedance plethysmography: a new method for continuous muscle perfusion monitoring.

    Science.gov (United States)

    Concannon, M J; Stewart, D H; Welsh, C F; Puckett, C L

    1991-08-01

    Vigilant postoperative monitoring of the buried muscle flap is critical after free transfer because early diagnosis of vascular insufficiency is essential to allow prompt correction. We have identified a monitoring method utilizing needle electrodes and impedance plethysmography that gives a beat-to-beat representation of muscular perfusion. In 25 New Zealand White rabbits the gastrocnemius muscle was isolated on its vascular pedicle, and two intramuscular needle electrodes were placed. The instantaneous impedance changes of the muscle (corresponding to the pulsatile volume changes of perfusion) were measured and recorded. Using this representation of perfusion, an independent judge was able to correctly diagnose muscular ischemia 100 percent of the time (n = 25). Further, the judge was able to correctly distinguish the ischemia as arterial (n = 10) or venous (n = 10) in origin 100 percent of the time. Additionally, we monitored muscle perfusion transcutaneously in five free muscle flaps and demonstrated a reliable impedance signal that correlated with perfusion.

  1. Oscillometric continuous blood pressure sensing for wearable health monitoring system

    CERN Document Server

    Gelao, Gennaro; Passaro, Vittorio M N; Perri, Anna Gina

    2015-01-01

    In this paper we present an acquisition chain for the measurement of blood arterial pressure based on the oscillometric method. This method does not suffer from any limitation as the well-known auscultatory method and it is suited for wearable health monitoring systems. The device uses a pressure sensor whose signal is filtered, digitalized and analyzed by a microcontroller. Local analysis allows the evaluation of the systolic and diastolic pressure values which can be used for local alarms, data collection and remote monitoring.

  2. Integrated system for remotely monitoring critical physiological parameters

    Science.gov (United States)

    Alexakis, S.; Karalis, S.; Asvestas, P.

    2015-09-01

    Monitoring several human parameters (temperature, heart rate, blood pressure etc.) is an essential task in health care in hospitals as well as in home care. This paper presents the design and implementation of an integrated, embedded system that includes an electrocardiograph of nine leads and two channels, a digital thermometer for measuring the body temperature and a power supply. The system provides networking capabilities (wired or wireless) and is accessible by means of a web interface that allows the user to select the leads, as well as to review the values of heart rate (beats per minute) and body temperature. Furthermore, there is the option of saving all the data in a Micro SD memory card or in a Google Spreadsheet. The necessary analog circuits for signal conditioning (amplification and filtering) were manufactured on printed circuit boards (PCB). The system was built around Arduino Yun, which is a platform that contains a microcontroller and a microprocessor running a special LINUX distribution. Furthermore, the Arduino Yun provides the necessary network connectivity capabilities by means of the integrated Wi-Fi and Ethernet interfaces. The web interface was developed using HTML pages with JavaScript support. The system was tested on simulated data as well as real data, providing satisfactory accuracy regarding the measurement of the heart rate (±3 bpm error) and the temperature (±0.3°C error).

  3. 77 FR 13977 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-03-08

    ... AGENCY 40 CFR Part 60 RIN 2060-AH23 Quality Assurance Requirements for Continuous Opacity Monitoring... final rule titled, ``Quality Assurance Requirements for Continuous Opacity Monitoring Systems at... electronically in www.regulations.gov or in hard copy at the Procedure 3--Quality Assurance Requirements for...

  4. 77 FR 8160 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-02-14

    ... AGENCY 40 CFR Part 60 RIN 2060-AH23 Quality Assurance Requirements for Continuous Opacity Monitoring...--Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources Docket, EPA.... Rules establishing quality assurance requirements impose no costs independent from national emission...

  5. The effect of real-time continuous glucose monitoring in pregnant women with diabetes

    DEFF Research Database (Denmark)

    Secher, Anna L; Ringholm, Lene; Damm, Peter;

    2013-01-01

    To assess whether intermittent real-time continuous glucose monitoring (CGM) improves glycemic control and pregnancy outcome in unselected women with pregestational diabetes.......To assess whether intermittent real-time continuous glucose monitoring (CGM) improves glycemic control and pregnancy outcome in unselected women with pregestational diabetes....

  6. 40 CFR 63.9808 - How do I monitor and collect data to demonstrate continuous compliance?

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false How do I monitor and collect data to demonstrate continuous compliance? 63.9808 Section 63.9808 Protection of Environment ENVIRONMENTAL PROTECTION... include out of control continuous monitoring systems (CMS), such as a CPMS. Any averaging period for...

  7. 75 FR 64411 - Lowering Miners' Exposure to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors

    Science.gov (United States)

    2010-10-19

    ... the CMDPSU or CPDM and the sampled work shift is less than 8 hours, the value of t used for... Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors; Proposed Rule #0;#0;Federal Register... to Respirable Coal Mine Dust, Including Continuous Personal Dust Monitors AGENCY: Mine Safety and...

  8. Reproducibility and reliability of hypoglycaemic episodes recorded with Continuous Glucose Monitoring System (CGMS) in daily life

    DEFF Research Database (Denmark)

    Høi-Hansen, T; Pedersen-Bjergaard, U; Thorsteinsson, B

    2005-01-01

    AIM: Continuous glucose monitoring may reveal episodes of unrecognized hypoglycaemia. We evaluated reproducibility and reliability of hypoglycaemic episodes recorded in daily life by the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS). METHODS: Twenty-nine adult patients with Type 1...

  9. Exploratory Study for Continuous-time Parameter Estimation of Ankle Dynamics

    Science.gov (United States)

    Kukreja, Sunil L.; Boyle, Richard D.

    2014-01-01

    Recently, a parallel pathway model to describe ankle dynamics was proposed. This model provides a relationship between ankle angle and net ankle torque as the sum of a linear and nonlinear contribution. A technique to identify parameters of this model in discrete-time has been developed. However, these parameters are a nonlinear combination of the continuous-time physiology, making insight into the underlying physiology impossible. The stable and accurate estimation of continuous-time parameters is critical for accurate disease modeling, clinical diagnosis, robotic control strategies, development of optimal exercise protocols for longterm space exploration, sports medicine, etc. This paper explores the development of a system identification technique to estimate the continuous-time parameters of ankle dynamics. The effectiveness of this approach is assessed via simulation of a continuous-time model of ankle dynamics with typical parameters found in clinical studies. The results show that although this technique improves estimates, it does not provide robust estimates of continuous-time parameters of ankle dynamics. Due to this we conclude that alternative modeling strategies and more advanced estimation techniques be considered for future work.

  10. Adaptive Multichannel Radiation Sensors for Plant Parameter Monitoring

    Science.gov (United States)

    Mollenhauer, Hannes; Remmler, Paul; Schuhmann, Gudrun; Lausch, Angela; Merbach, Ines; Assing, Martin; Mollenhauer, Olaf; Dietrich, Peter; Bumberger, Jan

    2016-04-01

    Nutrients such as nitrogen are playing a key role in the plant life cycle. They are much needed for chlorophyll production and other plant cell components. Therefore, the crop yield is strongly affected by plant nutrient status. Due to the spatial and temporal variability of soil characteristics or swaying agricultural inputs the plant development varies within a field. Thus, the determination of these fluctuations in the plant development is valuable for a detection of stress conditions and optimization of fertilisation due to its high environmental and economic impact. Plant parameters play crucial roles in plant growth estimation and prediction since they are used as indicators of plant performance. Especially indices derived out of remote sensing techniques provide quantitative information about agricultural crops instantaneously, and above all, non-destructively. Due to the specific absorption of certain plant pigments, a characteristic spectral signature can be seen in the visible and IR part of the electromagnetic spectrum, known as narrow-band peaks. In an analogous manner, the presence and concentration of different nutrients cause a characteristic spectral signature. To this end, an adequate remote sensing monitoring concept is needed, considering heterogeneity and dynamic of the plant population and economical aspects. This work will present the development and field investigations of an inexpensive multichannel radiation sensor to observe the incoming and reflected specific parts or rather distinct wavelengths of the solar light spectrum on the crop and facilitate the determination of different plant indices. Based on the selected sensor wavelengths, the sensing device allows the detection of specific parameters, e.g. plant vitality, chlorophyll content or nitrogen content. Besides the improvement of the sensor characteristic, the simple wavelength adaption, and the price-performance ratio, the achievement of appropriate energy efficiency as well as a

  11. Landsat continuity: issues and opportunities for land cover monitoring

    Science.gov (United States)

    Michael A. Wulder; Joanne C. White; Samuel N. Goward; Jeffrey G. Masek; James R. Irons; Martin Herold; Warren B. Cohen; Thomas R. Loveland; Curtis E. Woodcock

    2008-01-01

    Initiated in 1972, the Landsat program has provided a continuous record of Earth observation for 35 years. The assemblage of Landsat spatial, spectral, and temporal resolutions, over a reasonably sized image extent, results in imagery that can be processed to represent land cover over large areas with an amount of spatial detail that is absolutely unique and...

  12. A Distributed Approach to Continuous Monitoring of Constrained k-Nearest Neighbor Queries in Road Networks

    Directory of Open Access Journals (Sweden)

    Hyung-Ju Cho

    2012-01-01

    Full Text Available Given two positive parameters k and r, a constrained k-nearest neighbor (CkNN query returns the k closest objects within a network distance r of the query location in road networks. In terms of the scalability of monitoring these CkNN queries, existing solutions based on central processing at a server suffer from a sudden and sharp rise in server load as well as messaging cost as the number of queries increases. In this paper, we propose a distributed and scalable scheme called DAEMON for the continuous monitoring of CkNN queries in road networks. Our query processing is distributed among clients (query objects and server. Specifically, the server evaluates CkNN queries issued at intersections of road segments, retrieves the objects on the road segments between neighboring intersections, and sends responses to the query objects. Finally, each client makes its own query result using this server response. As a result, our distributed scheme achieves close-to-optimal communication costs and scales well to large numbers of monitoring queries. Exhaustive experimental results demonstrate that our scheme substantially outperforms its competitor in terms of query processing time and messaging cost.

  13. Extended BSI for continuous EEG monitoring in carotid endarterectomy

    NARCIS (Netherlands)

    van Putten, Michel Johannes Antonius Maria

    2006-01-01

    Abstract Objective Carotid endarterectomy is a common procedure as a secondary prevention of stroke, and is often performed with selective shunting. Although various EEG parameters have been proposed to determine if the brain is at risk during carotid artery clamping, the common procedure is still

  14. Extended BSI for continuous EEG monitoring in carotid endarterectomy

    NARCIS (Netherlands)

    van Putten, Michel Johannes Antonius Maria

    2006-01-01

    Abstract Objective Carotid endarterectomy is a common procedure as a secondary prevention of stroke, and is often performed with selective shunting. Although various EEG parameters have been proposed to determine if the brain is at risk during carotid artery clamping, the common procedure is still t

  15. Accuracy of continuous noninvasive arterial pressure monitoring in living-liver donors during transplantation.

    Science.gov (United States)

    Araz, Coskun; Zeyneloglu, Pinar; Pirat, Arash; Veziroglu, Nukhet; Camkiran Firat, Aynur; Arslan, Gulnaz

    2015-04-01

    Hemodynamic monitoring is vital during liver transplant surgeries because distinct hemodynamic changes are expected. The continuous noninvasive arterial pressure (CNAP) monitor is a noninvasive device for continuous arterial pressure measurement by a tonometric method. This study compared continuous noninvasive arterial pressure monitoring with invasive direct arterial pressure monitoring in living-liver donors during transplant. There were 40 patients analyzed while undergoing hepatic lobectomy for liver transplant. Invasive pressure monitoring was established at the radial artery and continuous noninvasive arterial pressure monitoring using a finger sensor was recorded simultaneously from the contralateral arm. Systolic, diastolic, and mean arterial pressures from the 2 methods were compared. Correlation between the 2 methods was calculated. A total of 5433 simultaneous measurements were obtained. For systolic arterial blood pressure, 55% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.479, continuous noninvasive arterial pressure bias was -0.3 mm Hg, and limits of agreement were 32.0 mm Hg. For diastolic arterial blood pressure, 50% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.630, continuous noninvasive arterial pressure bias was -0.4 mm Hg, and limits of agreement were 21.1 mm Hg. For mean arterial blood pressure, 60% continuous noninvasive arterial pressure measurements were within 10% direct arterial measurement; the correlation was 0.692, continuous noninvasive arterial pressure bias was +0.4 mm Hg, and limits of agreement were 20.8 mm Hg. The 2 monitoring techniques did not show acceptable agreement. Our results suggest that continuous noninvasive arterial pressure monitoring is not equivalent to invasive arterial pressure monitoring in donors during living-donor liver transplant.

  16. [Comparison of 2 systems for continuous intraoperative monitoring of oxygen saturation in the jugular bulb].

    Science.gov (United States)

    García del Valle, S; Bartolomé, A; Menéndez, B; Azofra, J; Requejo, M D

    1996-02-01

    To compare accuracy, precision and stability of two jugular venous blood catheters for continuous monitoring of oxygen saturation during surgery, in a nonrandom, prospective sample. We studied 47 patients requiring continuous monitoring of SjvO2 during a variety of neurosurgical procedures. Swan-Ganz pediatric 5.5F catheters (Opticath P575-EH) were used in 27 patients; neonatal umbilical artery 4F catheters (Opticath U425C) were used in 20. Both catheters were equipped with a fiberoptic system for continuous monitoring of hemoglobin oxygen saturation. After checking correct placement, readings transmitted were compared with co-oximetry readings for a sample taken from the distal end of the catheter. We also compared time spent placing the catheters and stability of SjvO2 reading during surgery. Insertion time (+/- SD) was 10.3 +/- 2.5 minutes for the 4F catheter and 15.9 +/- 5.5 minutes for the 5.5F model (p < 0.01). Although both systems tended to overestimate, the 5.5F catheters were more accurate: the mean differences were -6.8% for the 4F catheter and -1.2% for the 5.5F. These results made it necessary to calibrate the 4F catheters after placement and before use, a procedure not needed if the 5.5F catheters are used. Stability of SjvO2 readings during surgery was significantly greater (p < 0.01) for the 5.5F catheters, such that only 25.9% were considered clinically useful based on this parameter. However, 70% of the 5.5F catheters provided acceptable SjvO2 readings. Intracranial pressure during insertion and removal of the SjvO2 catheters was measured in only 5 patients; there were no changes greater than 1 mmHg. Although the 5.5F pediatric catheters take longer to put into position, their greater accuracy, precision and stability makes them preferable to the 4F catheters for continuous monitoring of SjvO2. Long-term vascular effects must be studied further.

  17. Applications and Methods for Continuous Monitoring of Physiological Chemistry

    Science.gov (United States)

    2016-02-04

    results returned. Continuous measurement of biomarkers including immunological signatures or particular subsets of proteins, nucleic acids, or small...period of at least 5 days following surgery . Following the recovery period, biosensors were lowered into the implanted guide cannula and a wireless...dosing. 3.3.f Lactate Oxidase Testing The lactate biosensors underwent both CNS and subcutaneous testing. In the CNS surgery , guide cannulas aimed

  18. Markers for detecting alcoholism and monitoring for continued abuse.

    Science.gov (United States)

    Morgan, M Y

    1980-01-01

    Several biochemical and haematological abnormalities are associated with excessive alcohol intake and some are used in the recognition and management of alcoholics. The ideal biological marker for detecting and monitoring alcoholics should be sensitive and highly specific for alcohol abuse; its value should be affected by changes in alcohol intake over relatively short periods of time and it should be quick, simple, convenient and inexpensive to estimate. At the present time no simple reliable marker is available which fulfills these criteria. Measurements of serum aspartate transaminase, serum gamma-glutamyl-transpeptidase and mean corpuscular volume are of proven value however and the majority of alcoholics can be detected and monitored by combining the measurements of these three tests. Blood/breath alcohol measurements are of limited value for detection but are useful for follow up. Measurement of the plasma alpha-amino-n-butyric acid/leucine ratio is of disputed value and not likely to be of great practical use. Measurement of serum alpha-lipoproteins, erythrocyte delta-aminolaevulinic acid dehydrase activity and qualitative estimation of serum transferrin have all been proposed as markers for alcohol abuse and are currently under evaluation.

  19. Soft wearable contact lens sensor for continuous intraocular pressure monitoring.

    Science.gov (United States)

    Chen, Guo-Zhen; Chan, Ion-Seng; Leung, Leo K K; Lam, David C C

    2014-09-01

    Intraocular pressure (IOP) is a primary indicator of glaucoma, but measurements from a single visit to the clinic miss the peak IOP that may occur at night during sleep. A soft chipless contact lens sensor that allows the IOP to be monitored throughout the day and at night is developed in this study. A resonance circuit composed of a thin film capacitor coupled with a sensing coil that can sense corneal curvature deformation is designed, fabricated and embedded into a soft contact lens. The resonance frequency of the sensor is designed to vary with the lens curvature as it changes with the IOP. The frequency responses and the ability of the sensor to track IOP cycles were tested using a silicone rubber model eye. The results showed that the sensor has excellent linearity with a frequency response of ∼8 kHz/mmHg, and the sensor can accurately track fluctuating IOP. These results showed that the chipless contact lens sensor can potentially be used to monitor IOP to improve diagnosis accuracy and treatment of glaucoma.

  20. Continuous monitoring versus HOLTER ECG for detection of atrial fibrillation in patients with stroke.

    Science.gov (United States)

    Gumbinger, C; Krumsdorf, U; Veltkamp, R; Hacke, W; Ringleb, P

    2012-02-01

    Detection of atrial fibrillation is of vital importance because oral anticoagulation decreases the risk of a stroke by 64%. Current standards for stroke unit treatment require continuous electrocardiogram (ECG) monitoring for at least 24 h. Additionally, a 24-h HOLTER ECG (HOLTER) should be performed in selected patients. It remains unclear whether continuous monitoring at the bedside is equivalent to HOLTER for the detection of atrial fibrillation. Furthermore, we investigate how many additional patients with paroxysmal atrial fibrillation can be identified as a result of a longer duration of continuous monitoring. In this study, we prospectively compared the detection rates of HOLTER and 24-h monitoring at the Stroke Unit at the University of Heidelberg over a period of 9 months. Continuous monitoring was analyzed by trained nurses, HOLTER by cardiologists. We included 370 patients with ischemic stroke or transient ischemic attack (TIA) in our study. Of these, 192 patients underwent HOLTER. Previously unknown atrial fibrillation was detected in 44 patients, 13 patients had no atrial fibrillation in baseline ECG, but atrial fibrillation was detected by continuous monitoring. In two patients, the HOLTER showed atrial fibrillation; both patients had also been detected by continuous monitoring. Median time to detection of the atrial fibrillation during continuous monitoring was 43 h after hospitalization. In this study, use of HOLTER does not give any additional benefit in comparison with continuous monitoring with intermittent analysis by trained staff alone. The median detection time of 43 h emphasizes the importance of longer continuous monitoring. © 2011 The Author(s). European Journal of Neurology © 2011 EFNS.

  1. Monitoring and modelling of a continuous from-powder-to-tablet process line

    DEFF Research Database (Denmark)

    Mortier, Séverine T.F.C.; Nopens, Ingmar; De Beer, Thomas

    2014-01-01

    The intention to shift from batch to continuous production processes within the pharmaceutical industry enhances the need to monitor and control the process in-line and real-time to continuously guarantee the end-product quality. Mass and energy balances have been successfully applied to a drying...... process which is part of a continuous from-powder-to-tablet manufacturing line to calculate the residual moisture content of granules leaving the drying unit on the basis of continuously generated data from univariate sensors. Next to monitoring, the application of continuous processes demands also real...

  2. Undersafe: Monitoring safety parameters in touristic mines and caves

    Science.gov (United States)

    Parcerisa, David; Sanmiquel, Lluís; Alfonso, Pura; Oliva, Josep

    2014-05-01

    Tourism is a key sector of the European economy, generating more than 5% of the EU GPD (Gross Domestic Product). Usually, underground touristic sites receive non-expert visitors; nevertheless these activities are poorly regulated or completely deregulated. Nowadays, safety is provided by underground expert professionals whom proceed to regular inspections and by basic safety infrastructures. Even with these measures, some potential personal and environmental dangers are always present and cannot be totally avoided. Therefore, there is a clear need of a new technological product for safety and environmental continuous monitoring of tourist underground attractions. So, the aim of the Undersafe project is to provide underground attractions with a novel and specifically tailored monitoring system, easy to use and maintain. One of the goals of the Undersafe project is to develop a rock falling detection based on a set of cost limited vibration sensors. Based on the technical needs, but with cost constraints, different types of potential sensors are considered: Underground microphone: It is placed in the surface or in the underground. It is based on the consideration that the impact of the stone generates a ground impact vibration which can be understood as a "noise" that is received by a microphone capsule. Airborne sound sensing microphone: It similarly applies to underground use of the microphones, but now the microphone is tested as for its traditional use (I.e. air sound detection). In such case, the microphone detects the environmental noise produced by the impact of the stone falling onto the ground, which will include the impact sound of the stone. Geophone: It is the de facto standard for ground vibrations. Although this technology was initially discarded due to its high cost, recently, low cost geophones have appeared in the market that allows its use inside the underground attractions. Accelerometers: These, can have enough sensibility to act as vibration

  3. 40 CFR 401.17 - pH Effluent limitations under continuous monitoring.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 28 2010-07-01 2010-07-01 true pH Effluent limitations under... (CONTINUED) EFFLUENT GUIDELINES AND STANDARDS GENERAL PROVISIONS § 401.17 pH Effluent limitations under continuous monitoring. (a) Where a permittee continuously measures the pH of wastewater pursuant to...

  4. Effects of continuous and intermittent magnetic fields on oxidative parameters in vivo.

    Science.gov (United States)

    Coşkun, Sule; Balabanli, Barbaros; Canseven, Ayşe; Seyhan, Nesrin

    2009-02-01

    Continuous and intermittent 50 Hz, 1.5 mT magnetic field with the exposure period of 4 h/day for 4 days was used to investigate its possible effect on adult guinea pigs. Tissues and plasma specimens were assessed by biochemical parameters. Malondialdehyde (MDA), glutathione (GSH), nitric oxide (NO) levels and myeloperoxidase activity (MPO) were examined in plasma, liver and brain tissues. All parameters were determined by spectrophotometer. While intermittent magnetic field was effective on plasma lipid peroxidation, continuous magnetic field was found to be effective on plasma MPO activity and NO levels. Augmentation of lipid peroxidation was also observed in liver tissue both intermittent and continuous magnetic field exposures. These results indicate that both the intermittent and continuous magnetic field exposures affect various tissues in a distinct manner because of having different tissue antioxidant status and responses.

  5. Effect of the Design Parameters on the Performance of Inner Recycling Continuous Sand Filter

    Institute of Scientific and Technical Information of China (English)

    CHEN Zhi-qiang; WEN Qin-xue; Lü Bing-nan

    2002-01-01

    A novel integrated water treatment facility, innerrecycling continuous sand filter, is discussed. The theory of micro-flocculation is applied in the sand-washing circulation system with continuous filtration and backwashing. The design and operation parameters,which affect the performance of the filter, are discussed.The key design parameters are provided as follows:diameter of filter material is 0.7 to 1.0 mm, depth of filter bed is 0.6 m, filtration velocity is less than 12 m/h,ratio of gas to water is 9:11 and sand recycling rate is 2 to 4 mm/min.

  6. Chesapeake Bay subsidence monitored as wetlands loss continues

    Science.gov (United States)

    Nerem, R. S.; van Dam, T. M.; Schenewerk, M. S.

    Fragile wetland ecosystems, which support an abundance of wildlife, are being lost around the Chesapeake Bay at an alarming rate due to an increase in sea level. For example, one third of the total area of the Blackwater National Wildlife Refuge (Figure 1) (approximately 20 km2) was lost between 1938 and 1979 [Leatherman, 1992]. Approximately 4,100 km2 of the perimeter of the Chesapeake Bay are covered by wetlands of which 58% forested wetlands and 28% are salt marshes. It is likely that many factors are responsible for the wetlands loss, some that have global implications, and some that reflect local phenomena.Understanding the mechanisms responsible for wetlands deterioration and loss, however, has been impeded by the lack of adequate data including quantitative monitoring of the types and distribution of flora, Tthe boundaries of specific habitat types, and data on the spatial variations in sea level and land subsidence. This article focuses on the latter problem, which is to determine the relative roles of sea level rise and land subsidence in the region. Over the past four years, a small network of Global Positioning System (GPS) receivers have been installed near tide gauges in the Chesapeake Bay to help determine the cause of relative sea level rise in this region. These receivers are just beginning to yield results.

  7. Chloroplasts continuously monitor photoreceptor signals during accumulation movement.

    Science.gov (United States)

    Tsuboi, Hidenori; Wada, Masamitsu

    2013-07-01

    Under low light conditions, chloroplasts gather at a cell surface to maximize light absorption for efficient photosynthesis, which is called the accumulation response. Phototropin1 (phot1) and phototropin2 (phot2) were identified as blue light photoreceptors in the accumulation response that occurs in Arabidopsis thaliana and Adiantum capillus-veneris with neochrome1 (neo1) as a red light photoreceptor in A. capillus-veneris. However, the signal molecule that is emitted from the photoreceptors and transmitted to the chloroplasts is not known. To investigate this topic, the accumulation response was induced by partial cell irradiation with a microbeam of red, blue and far-red light in A. capillus-veneris gametophyte cells. Chloroplasts moved towards the irradiated region and were able to sense the signal as long as its signal flowed. The signal from neo1 had a longer life than the signal that came from phototropins. When two microbeams with the same wavelength and the same fluence rate were placed 20 μm apart from each other and were applied to a dark-adapted cell, chloroplasts at an equidistant position always moved towards the center (midpoint) of the two microbeams, but not towards either one. This result indicates that chloroplasts are detecting the concentration of the signal but not the direction of signal flow. Chloroplasts repeatedly move and stop at roughly 10 s intervals during the accumulation response, suggesting that they monitor the intermittent signal waves from photoreceptors.

  8. Dynamic Radioactive Source for Evaluating and Demonstrating Time-dependent Performance of Continuous Air Monitors.

    Science.gov (United States)

    McLean, Thomas D; Moore, Murray E; Justus, Alan L; Hudston, Jonathan A; Barbé, Benoît

    2016-11-01

    Evaluation of continuous air monitors in the presence of a plutonium aerosol is time intensive, expensive, and requires a specialized facility. The Radiation Protection Services Group at Los Alamos National Laboratory has designed a Dynamic Radioactive Source, intended to replace plutonium aerosol challenge testing. The Dynamic Radioactive Source is small enough to be inserted into the sampler filter chamber of a typical continuous air monitor. Time-dependent radioactivity is introduced from electroplated sources for real-time testing of a continuous air monitor where a mechanical wristwatch motor rotates a mask above an alpha-emitting electroplated disk source. The mask is attached to the watch's minute hand, and as it rotates, more of the underlying source is revealed. The measured alpha activity increases with time, simulating the arrival of airborne radioactive particulates at the air sampler inlet. The Dynamic Radioactive Source allows the temporal behavior of puff and chronic release conditions to be mimicked without the need for radioactive aerosols. The new system is configurable to different continuous air monitor designs and provides an in-house testing capability (benchtop compatible). It is a repeatable and reusable system and does not contaminate the tested air monitor. Test benefits include direct user control, realistic (plutonium) aerosol spectra, and iterative development of continuous air monitor alarm algorithms. Data obtained using the Dynamic Radioactive Source has been used to elucidate alarm algorithms and to compare the response time of two commercial continuous air monitors.

  9. Continuous Earth Rotation Monitoring with the large Ring Laser G

    Science.gov (United States)

    Schreiber, K. U.; Klügel, T.; Wells, J. P.; Holdaway, J.; Gebauer, A.

    2010-12-01

    Over the last decade, ring lasers have found their way back into the research laboratories. By scaling them up in size, they have gained several orders of magnitude over their commercial counterparts, both in sensitivity and stability. Unlike the established space geodetic techniques SLR/LLR and VLBI, ring lasers can be operated autonomous and continuously. Furthermore laser gyros reach a resolution of 1 pico-rad/s already after an integration time of less than 2 hours. This opens the door for the research of high frequency variations in Earth rotation. Over the last year we have improved the sensor sensitivity by as much as a factor of 3 in order to reach the shot noise limit at 2.1x10-11 rad/s/sqrt(Hz). So the regime of ΔΩ/Ω ≈ 10-9 of Earth rotation becomes accessible to a local rotation sensor. Recent efforts concentrate on the reduction of scale factor instability by controlling the drift induced by atmospheric pressure variations and the corresponding temperature changes from adiabatic expansion and compression of the local air as well as a new approach to the modeling of the behavior of the sensor location. This talk outlines recent progress in Sagnac interferometry.

  10. A CAVITY RING-DOWN SPECTROSCOPY MERCURY CONTINUOUS EMISSION MONITOR

    Energy Technology Data Exchange (ETDEWEB)

    Christopher C. Carter

    2002-12-31

    SRD tested a number of different length cavities during this past quarter. Continuous transmission was observed with cavity lengths from 65 to 12 cm. The 65 cm cavity was replaced with a 39 cm cavity for work performed during this quarter. Flue gas components were tested for background absorptions and any interference with the determination of accurate mercury concentrations. Sulfur dioxide was found to absorb fairly strongly in the region of the mercury transition, but the Cavity Ring-Down (CRD) instrument was still able to detect mercury at subparts-per-billion by volume (ppb) levels. Additional flue gases tested included H{sub 2}O, CO, CO{sub 2}, NO, NO{sub 2}. None of these flue gas constituents showed any observable absorption in the ultraviolet region near the atomic mercury transition. Work was also initiated in speciation studies. In particular mercury chloride (HgCl{sub 2}) was tested. A mercury signal was detected from a gas stream containing HgCl{sub 2}. SRD was not able to determine definitively if there exists a spectral shift great enough to separate HgCl{sub 2} from elemental mercury in these initial tests.

  11. An implementation of continuous genetic algorithm in parameter estimation of predator-prey model

    Science.gov (United States)

    Windarto

    2016-03-01

    Genetic algorithm is an optimization method based on the principles of genetics and natural selection in life organisms. The main components of this algorithm are chromosomes population (individuals population), parent selection, crossover to produce new offspring, and random mutation. In this paper, continuous genetic algorithm was implemented to estimate parameters in a predator-prey model of Lotka-Volterra type. For simplicity, all genetic algorithm parameters (selection rate and mutation rate) are set to be constant along implementation of the algorithm. It was found that by selecting suitable mutation rate, the algorithms can estimate these parameters well.

  12. Small-angle light scattering by airborne particulates: Environnement S.A. continuous particulate monitor

    Science.gov (United States)

    Renard, Jean-Baptiste; Thaury, Claire; Mineau, Jean-Luc; Gaubicher, Bertrand

    2010-08-01

    Airborne particulate matter may have an effect on human health. It is therefore necessary to determine and control in real time the evolution of the concentration and mass of particulates in the ambient air. These parameters can be obtained using optical methods. We propose here a new instrument, 'CPM' (continuous particulate monitor), for the measurement of light scattered by ambient particulates at small angles. This geometry allows simultaneous and separate detections of PM10, PM2.5 and PM1 fractions of airborne particulate matter, with no influence of their chemical nature and without using theoretical calculations. The ambient air is collected through a standard sampling head (PM10 inlet according to EN 12341, PM2.5 inlet according to EN 14907; or PM1, TSP inlets, standard US EPA inlets). The analysis of the first measurements demonstrates that this new instrument can detect, for each of the seven defined size ranges, real-time variations of particulate content in the ambient air. The measured concentrations (expressed in number per liter) can be converted into total mass concentrations (expressed in micrograms per cubic meter) of all fractions of airborne particulate matters sampled by the system. Periodic comparison with a beta-attenuation mass monitor (MP101M Beta Gauge Analyzer from Environnement S.A. company) allows the calculation of a calibration factor as a function of the mean particulate density that is used for this conversion. It is then possible to provide real-time relative variations of aerosol mass concentration.

  13. Geoacoustic method for continuous monitoring of stressed-strained state of Earth's crust

    Science.gov (United States)

    Verbitskiy, T. Z.

    1984-05-01

    Ceramic piezoelectric transducers with characteristic frequencies 10-15 KHz are used as sources and detectors of longitudinal waves in a geoacoustic measuring system. The source is excited by an alternating voltage of 150-300 V with a frequency of 1-10 KHz. The electric signals from the detectors are amplified and filtered for discriminating the frequency harmonics. The phase shift of the received signal of the fundamental frequency and the amplitude of oscillations of the fundamental and multiple frequencies are determined. The measured wave parameters are registered on punched tape, facilitating computer input. Measuring system stability is monitored. The supply voltage, as well as atmospheric pressure, humidity and temperature are continuously monitored. Measurements made in the Carpathian Geodynamic Polygon Carpathian reveal a substantial influence of tidal deformations of the Earth. It can be postulated that short anomalies are caused by the discharge of stresses in the investigated rock complex. More prolonged anomalies are caused by deformations of the crust accompanying preparation for tectonic earthquakes.

  14. Non-Invasive Continuous Respiratory Monitoring on General Hospital Wards : A Systematic Review

    NARCIS (Netherlands)

    van Loon, Kim|info:eu-repo/dai/nl/341748501; van Zaane, Bas|info:eu-repo/dai/nl/311475361; Bosch, Els J; Kalkman, Cor J|info:eu-repo/dai/nl/078251818; Peelen, Linda M|info:eu-repo/dai/nl/314038426

    2015-01-01

    BACKGROUND: Failure to recognize acute deterioration in hospitalized patients may contribute to cardiopulmonary arrest, unscheduled intensive care unit admission and increased mortality. PURPOSE: In this systematic review we aimed to determine whether continuous non-invasive respiratory monitoring i

  15. Monitoring Key Parameters in Bioprocesses Using Near-Infrared Technology

    Directory of Open Access Journals (Sweden)

    Elena Tamburini

    2014-10-01

    Full Text Available Near-infrared spectroscopy (NIRS is known to be a rapid and non-destructive technique for process monitoring. Bioprocesses are usually complex, from both the chemical (ill-defined medium composition and physical (multiphase matrix aspects, which poses an additional challenge to the development of robust calibrations. We investigated the use of NIRS for on-line and in-line monitoring of cell, substrate and product concentrations, during aerobic and anaerobic bacterial fermentations, in different fermentation strategies. Calibration models were built up, then validated and used for the automated control of fermentation processes. The capability of NIR in-line to discriminate among differently shaped bacteria was tested.

  16. Dynamic Bayesian estimation of displacement parameters of continuous curve box based on Novozhilov theory

    Institute of Scientific and Technical Information of China (English)

    ZHANG Jian; YE Jian-shu; ZHAO Xin-ming

    2007-01-01

    The finite strip controlling equation of pinned curve box was deduced on basis of Novozhilov theory and with flexibility method, and the problem of continuous curve box was resolved. Dynamic Bayesian error function of displacement parameters of continuous curve box was found. The corresponding formulas of dynamic Bayesian expectation and variance were derived. After the method of solving the automatic search of step length was put forward, the optimization estimation computing formulas were also obtained by adapting conjugate gradient method. Then the steps of dynamic Bayesian estimation were given in detail. Through analysis of a classic example, the criterion of judging the precision of the known information is gained as well as some other important conclusions about dynamic Bayesian stochastic estimation of displacement parameters of continuous curve box.

  17. Long distance high power optical laser fiber break detection and continuity monitoring systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Rinzler, Charles C.; Gray, William C.; Faircloth, Brian O.; Zediker, Mark S.

    2016-02-23

    A monitoring and detection system for use on high power laser systems, long distance high power laser systems and tools for performing high power laser operations. In particular, the monitoring and detection systems provide break detection and continuity protection for performing high power laser operations on, and in, remote and difficult to access locations.

  18. 40 CFR 63.8615 - How do I monitor and collect data to demonstrate continuous compliance?

    Science.gov (United States)

    2010-07-01

    ... periods of monitor malfunctions, associated repairs, and required quality assurance or control activities... monitoring malfunctions, associated repairs, out-of-control periods, or required quality assurance or control... SOURCE CATEGORIES (CONTINUED) National Emission Standards for Hazardous Air Pollutants for Clay Ceramics...

  19. Long distance high power optical laser fiber break detection and continuity monitoring systems and methods

    Energy Technology Data Exchange (ETDEWEB)

    Rinzler, Charles C.; Gray, William C.; Faircloth, Brian O.; Zediker, Mark S.

    2016-02-23

    A monitoring and detection system for use on high power laser systems, long distance high power laser systems and tools for performing high power laser operations. In particular, the monitoring and detection systems provide break detection and continuity protection for performing high power laser operations on, and in, remote and difficult to access locations.

  20. 40 CFR 141.87 - Monitoring requirements for water quality parameters.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Monitoring requirements for water... § 141.87 Monitoring requirements for water quality parameters. All large water systems, and all small... representative of water quality and treatment conditions throughout the system. (d) Monitoring after State...

  1. Assessment of a continuous blood gas monitoring system in animals during circulatory stress

    Directory of Open Access Journals (Sweden)

    Renzulli Attilio

    2011-01-01

    Full Text Available Abstract Background The study was aimed to determine the measurement accuracy of The CDI™ blood parameter monitoring system 500 (Terumo Cardiovascular Systems Corporation, Ann Arbor MI in the real-time continuous measurement of arterial blood gases under different cardiocirculatory stress conditions Methods Inotropic stimulation (Dobutamine 2.5 and 5 μg/kg/min, vasoconstriction (Arginine-vasopressin 4, 8 and 16 IU/h, hemorrhage (-10%, -20%, -35%, and -50% of the theoretical volemia, and volume resuscitation were induced in ten swine (57.4 ± 10.7 Kg.Intermittent blood gas assessments were carried out using a routine gas analyzer at any experimental phase and compared with values obtained at the same time settings during continuous monitoring with CDI™ 500 system. The Bland-Altman analysis was employed. Results Bias and precision for pO2 were - 0.06 kPa and 0.22 kPa, respectively (r2 = 0.96; pCO2 - 0.02 kPa and 0.15 kPa, respectively; pH -0.001 and 0.01 units, respectively ( r2 = 0.96. The analysis showed very good agreement for SO2 (bias 0.04,precision 0.33, r2 = 0.95, Base excess (bias 0.04,precision 0.28, r2 = 0.98, HCO3 (bias 0.05,precision 0.62, r2 = 0.92,hemoglobin (bias 0.02,precision 0.23, r2 = 0.96 and K+ (bias 0.02, precision 0.27, r2 = 0.93. The sensor was reliable throughout the experiment during hemodynamic variations. Conclusions Continuous blood gas analysis with the CDI™ 500 system was reliable and it might represent a new useful tool to accurately and timely monitor gas exchange in critically ill patients. Nonetheless, our findings need to be confirmed by larger studies to prove its reliability in the clinical setting.

  2. Continuous Glucose Monitoring Enables the Detection of Losses in Infusion Set Actuation (LISAs

    Directory of Open Access Journals (Sweden)

    Daniel P. Howsmon

    2017-01-01

    Full Text Available Reliable continuous glucose monitoring (CGM enables a variety of advanced technology for the treatment of type 1 diabetes. In addition to artificial pancreas algorithms that use CGM to automate continuous subcutaneous insulin infusion (CSII, CGM can also inform fault detection algorithms that alert patients to problems in CGM or CSII. Losses in infusion set actuation (LISAs can adversely affect clinical outcomes, resulting in hyperglycemia due to impaired insulin delivery. Prolonged hyperglycemia may lead to diabetic ketoacidosis—a serious metabolic complication in type 1 diabetes. Therefore, an algorithm for the detection of LISAs based on CGM and CSII signals was developed to improve patient safety. The LISA detection algorithm is trained retrospectively on data from 62 infusion set insertions from 20 patients. The algorithm collects glucose and insulin data, and computes relevant fault metrics over two different sliding windows; an alarm sounds when these fault metrics are exceeded. With the chosen algorithm parameters, the LISA detection strategy achieved a sensitivity of 71.8% and issued 0.28 false positives per day on the training data. Validation on two independent data sets confirmed that similar performance is seen on data that was not used for training. The developed algorithm is able to effectively alert patients to possible infusion set failures in open-loop scenarios, with limited evidence of its extension to closed-loop scenarios.

  3. Ascertainment-adjusted parameter estimation approach to improve robustness against misspecification of health monitoring methods

    Science.gov (United States)

    Juesas, P.; Ramasso, E.

    2016-12-01

    Condition monitoring aims at ensuring system safety which is a fundamental requirement for industrial applications and that has become an inescapable social demand. This objective is attained by instrumenting the system and developing data analytics methods such as statistical models able to turn data into relevant knowledge. One difficulty is to be able to correctly estimate the parameters of those methods based on time-series data. This paper suggests the use of the Weighted Distribution Theory together with the Expectation-Maximization algorithm to improve parameter estimation in statistical models with latent variables with an application to health monotonic under uncertainty. The improvement of estimates is made possible by incorporating uncertain and possibly noisy prior knowledge on latent variables in a sound manner. The latent variables are exploited to build a degradation model of dynamical system represented as a sequence of discrete states. Examples on Gaussian Mixture Models, Hidden Markov Models (HMM) with discrete and continuous outputs are presented on both simulated data and benchmarks using the turbofan engine datasets. A focus on the application of a discrete HMM to health monitoring under uncertainty allows to emphasize the interest of the proposed approach in presence of different operating conditions and fault modes. It is shown that the proposed model depicts high robustness in presence of noisy and uncertain prior.

  4. [Influence of treatment with olmesartan on ambulatory blood pressure monitoring parameters in patients with arterial hypertension].

    Science.gov (United States)

    Bregvadze, T R; Tseluĭko, V I; Mishchuk, N E

    2013-12-01

    Hypertension is the most common disease of the cardiovascular system. Active treatment of hypertension with adequate control of blood pressure (BP) can prevent complications, improve life quality and increase life expectancy. One of the interesting new antihypertensive agents, from the group of angiotensin receptor blockers is olmesartan. The obvious advantages of ambulatory blood pressure monitoring to traditional one-time measurements of BP make this method perspective for quality control of anti-hypertensive therapy. The aim of this study was to evaluate the influence of treatment with olmesartan on ambulatory blood pressure monitoring parameters in patients with hypertension. 38 out-patients with hypertension at the age of 25-84 years (mean 55,3±10,6) were studied. Patients received olmesartan 20 mg daily as monotherapy (20 patients (52,6%)) or in combination with other antihypertensive agents (18 patients (47,4%)). Treatment continued for 6 months. The complex examination included: measurement of office brachial BP, electrocardiography, echocardiography and ambulatory blood pressure monitoring (ABPM). As a result of treatment, office BP and diurnal BP, according to ABPM, significantly decreased; the favorable circadian BP profile dynamics were found: significantly less frequently observed lack of reduction in BP during night (daily index - non-dipper) - 18% vs. 64% (p treatment of hypertensive patients with olmesartan provides significant decline not only in office BP, but also in diurnal BP, normalizes BP of active and passive periods, also - daily index and reduces BP variability.

  5. Assessment of duodenogastric reflux by combined continuous intragastric pH and bilirubin monitoring

    Institute of Scientific and Technical Information of China (English)

    Fei Dai; Jun Gong; Ru Zhang; Jin-Yan Luo; You-Ling Zhu; Xue-Qin Wang

    2002-01-01

    AIM: To assess the diagnostic value of a combination of continuous intragastric pH and bilirubin monitoring in the detection of duodenogastric reflux (DGR), and the effects of diet on the bilirubin absorbance.METHODS: 30 healthy volunteers were divided into twogroups: standard diet group (Group 1) 18 cases, free diet group (Group 2) 12 cases. Each subjects were subjected to simultaneous 24 hour intragastric pH and spectrophotometric bilirubin concentration monitoring (Bilitec 2000).RESULTS: There was no difference of preprandial phasebilirubin absorbance between two groups. The absorbanceof postprandial phase was significantly increased in group 2than group 1. There was no difference between preprandialphase and postprandial phase absorbance in group 1.Postprandial phase absorbance was significantly higher ingroup 2. In a comparison of bile reflux with intragastric pHduring night time, there were 4 types of reflux:Simultaneous increase in absorbance and pH in only 19.6%, increase in bilirubin with unchanged pH 33. 3 %, pHincrease with unchanged absorbance 36. 3 %, and bothunchanged in 10. 8 %. Linear regression analysis showed nocorrelation between percertage total time of pH < 4 aridpercentage total time of absortance > 0. 14, r=0.068, P<0.05.CONCLUSION: Because of the dietary effect, highabsorbance fluids or foods should be avoided in detection.Intrsgastric pH and bilirubin monitoring separately predictthe presence of duodenal (and/or pancreatic) reflux and bilereflux. They can not substitute for each other. The detectionof DGR is improved if the two parameters are combinedsimultanoously.

  6. Low power and self-reconfigurable WBAN controller for continuous bio-signal monitoring system.

    Science.gov (United States)

    Lee, Seulki; Yoo, Hoi-Jun

    2013-04-01

    The WBAN controller with Branched Bus (BB) topology and Continuous Data Transmission (CDT) protocol with low power consumption and self-reconfigurability is proposed for wearable healthcare applications. The BB topology and CDT protocol is a combination of conventional Bus and Star topology and a variation from TDMA protocol, respectively, while they are able to compensate for the electrical fault in bio-signal monitoring system caused by the electrode deformation. Thanks to them, the proposed WBAN controller enables more reliable operation in continuous bio-signal monitoring applications such as sleep monitoring.

  7. Monitoring diesel engine parameters based on FBG probe

    Science.gov (United States)

    Zhang, Hao; Jiang, Qi; Wang, Bao-yan; Wang, Jun-jie

    2016-09-01

    This paper proposes an unprecedented systematic approach for real-time monitoring the temperature and flow of diesel engine by using embedded fiber Bragg grating (FBG). By virtue of FBG's temperature effect, we design a novel sensitive FBG temperature sensing probe to measure the temperature of cylinder head and inlet flow of diesel engine. We also establish the corresponding software platform for intuitive data analysis. The experimental and complementary simulation results simultaneously demonstrate that the FBG-based optical fiber technique possesses extraordinary reproducibility and sensitivity, which makes it feasible to monitor the temperature and inlet flow of diesel engine. Our work can provide an effective way to evaluate the thermal load of cylinder head in diesel engine.

  8. Extracting source parameters from beam monitors on a chopper spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Abernathy, Douglas L [ORNL; Niedziela, Jennifer L [ORNL; Stone, Matthew B [ORNL

    2015-01-01

    The intensity distributions of beam monitors in direct-geometry time-of-flight neutron spectrometers provide important information about the instrument resolution. For short-pulse spallation neutron sources in particular, the asymmetry of the source pulse may be extracted and compared to Monte Carlo source simulations. An explicit formula using a Gaussian-convolved Ikeda-Carpenter distribution is given and compared to data from the ARCS instrument at the Spallation Neutron Source.

  9. Parameter-space metric of semicoherent searches for continuous gravitational waves

    CERN Document Server

    Pletsch, Holger J

    2010-01-01

    Continuous gravitational-wave (CW) signals such as emitted by spinning neutron stars are an important target class for current detectors. However, the enormous computational demand prohibits fully-coherent broadband all-sky searches for prior unknown CW sources over wide ranges of parameter space and for year-long observation times. More efficient hierarchical "semicoherent" search strategies divide the data into segments much shorter than one year, which are analyzed coherently; then detection statistics from different segments are combined incoherently. To optimally perform the incoherent combination, understanding of the underlying parameter-space structure is requisite. This problem is addressed here by using new coordinates on the parameter space, which yield the first analytical parameter-space metric for the incoherent combination step. This semicoherent metric applies to broadband all-sky surveys (also embedding directed searches at fixed sky position) for isolated CW sources. Furthermore, the additio...

  10. 77 FR 18709 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-03-28

    ... AGENCY 40 CFR Part 60 RIN 2060-AH23 Quality Assurance Requirements for Continuous Opacity Monitoring... final rule. SUMMARY: The EPA published a direct final rule titled ``Quality Assurance Requirements for....regulations.gov or in hard copy at the Procedure 3--Quality Assurance Requirements for Continuous Opacity...

  11. 78 FR 65306 - Best Practices for Continuous Monitoring of Temperature and Flow in Wadeable Streams

    Science.gov (United States)

    2013-10-31

    ... AGENCY Best Practices for Continuous Monitoring of Temperature and Flow in Wadeable Streams AGENCY...: EPA is announcing a 30-day public comment period for the draft document titled, ``Best Practices for... Development. The report describes best practices for the deployment of continuous temperature and flow sensors...

  12. Solar oxidation and removal of arsenic--Key parameters for continuous flow applications.

    Science.gov (United States)

    Gill, L W; O'Farrell, C

    2015-12-01

    Solar oxidation to remove arsenic from water has previously been investigated as a batch process. This research has investigated the kinetic parameters for the design of a continuous flow solar reactor to remove arsenic from contaminated groundwater supplies. Continuous flow recirculated batch experiments were carried out under artificial UV light to investigate the effect of different parameters on arsenic removal efficiency. Inlet water arsenic concentrations of up to 1000 μg/L were reduced to below 10 μg/L requiring 12 mg/L iron after receiving 12 kJUV/L radiation. Citrate however was somewhat surprisingly found to promote a detrimental effect on the removal process in the continuous flow reactor studies which is contrary to results found in batch scale tests. The impact of other typical water groundwater quality parameters (phosphate and silica) on the process due to their competition with arsenic for photooxidation products revealed a much higher sensitivity to phosphate ions compared to silicate. Other results showed no benefit from the addition of TiO2 photocatalyst but enhanced arsenic removal at higher temperatures up to 40 °C. Overall, these results have indicated the kinetic envelope from which a continuous flow SORAS single pass system could be more confidently designed for a full-scale community groundwater application at a village level.

  13. Increasing the Performance and Reliability of Power Boiler by Monitoring Thermal and Strength Parameters

    OpenAIRE

    Sobota Tomasz

    2017-01-01

    The paper presents a method for determination of thermo-flow parameters for steam boilers. This method allows to perform the calculations of the boiler furnace chamber and heat flow rates absorbed by superheater stages. These parameters are important for monitoring the performance of the power unit. Knowledge of these parameters allows determining the degree of the furnace chamber slagging. The calculation can be performed in online mode and use to monitoring of steam boiler. The presented me...

  14. Continuous EEG monitoring in adults in the intensive care unit (ICU).

    Science.gov (United States)

    André-Obadia, N; Parain, D; Szurhaj, W

    2015-03-01

    Continuous EEG monitoring in the ICU is different from planned EEG due to the rather urgent nature of the indications, explaining the fact that recording is started in certain cases by the clinical team in charge of the patient's care. Close collaboration between neurophysiology teams and intensive care teams is essential. Continuous EEG monitoring can be facilitated by quantified analysis systems. This kind of analysis is based on certain signal characteristics, such as amplitude or frequency content, but raw EEG data should always be interpreted if possible, since artefacts can sometimes impair quantified EEG analysis. It is preferable to work within a tele-EEG network, so that the neurophysiologist has the possibility to give an interpretation on call. Continuous EEG monitoring is thus useful in the diagnosis of non-convulsive epileptic seizures or purely electrical discharges and in the monitoring of status epilepticus when consciousness disorders persist after initial treatment. A number of other indications are currently under evaluation.

  15. Monitoring Re-execution Condition of Continuous Action Step in Computerized Procedure System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yun Goo; Lee, Sung Jin [KHNP Co., Daejeon (Korea, Republic of)

    2010-05-15

    The APR1400 digital main control room (MCR) has many advanced features of computerized control room. One of the most important improvements is the Computerized Procedure System (CPS). Emergency operating procedure (EOP) in the Nuclear Power Plant (NPP) provides a series of instructions to MCR operators to cope with design base events. Computerized EOP supports the operator in terms of plant monitoring, decision making, and control access. Continuous Action Step (CAS) in EOP should be monitored through the entire procedure execution when plant processes are disturbed under emergency conditions. CPS can monitor CAS re-execution condition during EOP execution. CPS has functions to monitor CAS re-execution condition

  16. The effect of continuous grouping of pigs in large groups on stress response and haematological parameters

    DEFF Research Database (Denmark)

    Damgaard, Birthe Marie; Studnitz, Merete; Jensen, Karin Hjelholt

    2009-01-01

    from weaning at the age of 4 weeks to the age of 18 weeks after weaning. Limited differences were found in stress and haematological parameters between pigs in dynamic and static groups. The cortisol response to the stress test was increasing with the duration of the stress test in pigs from......The consequences of an ‘all in-all out' static group of uniform age vs. a continuously dynamic group with litter introduction and exit every third week were examined with respect to stress response and haematological parameters in large groups of 60 pigs. The experiment included a total of 480 pigs...

  17. Process Parameters of Manufacturing Single Crystal Copper by Heated Mold Continuous Casting

    Institute of Scientific and Technical Information of China (English)

    XU Guangji; DING Zongfu; DING Yutian; KOU Shengzhong; LIU Guanglin; LI Wei

    2005-01-01

    The effect of process parameters on the surface quality of single crystal copper ingot was studied through experiment with a self-designed horizontal heated mould continuous casting apparatus, and the mechanism was analyzed. The results show that the process parameters affect the surface quality of pure copper ingot by affecting the position of the liquid-solid interface in the mould. The position of the liquid-solid interface in the mould must be controlled carefully in an appropriate range determined through experiments in order to gain a single crystal copper ingot with a high surface quality.

  18. Monitoring of Robot Assisted Polishing through parameters of acoustic emission

    DEFF Research Database (Denmark)

    Lazarev, Ruslan; Top, Søren; Bilberg, Arne

    , the duration of each process stage and predict the end of process in a precise and unmanned way. This paper presents and analyses the utilization of acoustic emission for generation of control signals in the stone polishing process for achieving these control objectives in an industrial set-up prototype........ The determination of the point in time to change a polishing media or stop the process is needed for computer controlled functional surface generation. During the last years, several research works have been done in order to build grinding/polishing monitoring systems to determine process characteristics...

  19. Monitoring of Robot Assisted Polishing through parameters of acoustic emission

    DEFF Research Database (Denmark)

    Lazarev, Ruslan; Top, Søren; Bilberg, Arne

    The polishing process is essential for the surface generation of machine tooling components in advanced manufacturing. While robot assisted polishing is faster and more consistent than manual polishing, it can still consume a significant part of ma- chining time and operator presence time....... The determination of the point in time to change a polishing media or stop the process is needed for computer controlled functional surface generation. During the last years, several research works have been done in order to build grinding/polishing monitoring systems to determine process characteristics...

  20. Multi-parameter monitoring of a slow moving landslide in Gresten (Austria)

    Science.gov (United States)

    Canli, Ekrem; Thiebes, Benni; Engels, Alexander; Glade, Thomas; Schweigl, Joachim; Bertagnoli, Michael

    2015-04-01

    Landslides pose a major threat around the world, to both human life and infrastructure. This may be an even bigger issue in the near future, as an increased landslide activity is commonly listed as an expected impact of human-induced climate change, together with an increasing population growth and the further demand of living space. This requires sound and appropriate means of monitoring slopes prone to landsliding. Monitoring systems for investigating kinematic aspects of landslides aid in analyzing, interpreting, and ultimately understanding its spatio-temporal movement behavior. Landslides around the world greatly differ in terms of typology, movement patterns and geometry, thus, making it difficult to establish a one-fits-all monitoring solution. The linkage between multiple systems with automated instrumentation has often demonstrated the benefits of continuous surveillance in terms of predicting and early warning forthcoming landslide movements. Within this presentation, we introduce a recently established long-term monitoring site on the active Salcher landslide that makes use of an innovative multi-parameter system. The investigated landslide is situated in the municipality of Gresten (Austria) and extends over approx. 8000 m². This slow moving, deep-seated landslide is geologically located in the Gresten Klippenbelt (Helvetic Zone). The characteristic lithofacies are the Gresten Beds of Early Jurassic age that is covered by a sequence of marly and silty beds with intercalated sandy limestones. Together with the adjacent Flyschzone, this area exhibits one of the highest landslide susceptibility within Austria. The monitoring setup consists both of surface and subsurface systems. Surface measurements on multiple locations are performed with highly sensitive sensor networks that measure surface inclination and acceleration. These are wirelessly connected with each other, highly flexible and constructed with a high longevity, yet still at a high measurement

  1. Using Analytical and Numerical Modeling to Assess the Utility of Groundwater Monitoring Parameters at Carbon Capture, Utilization, and Storage Sites

    Science.gov (United States)

    Porse, S. L.; Hovorka, S. D.; Young, M.; Zeidouni, M.

    2012-12-01

    Carbon capture, utilization, and storage (CCUS) is becoming an important bridge to commercial geologic sequestration (GS) to help reduce anthropogenic CO2 emissions. While CCUS at brownfield sites (i.e. mature oil and gas fields) has operational advantages over GS at greenfield sites (i.e. saline formations) such as the use of existing well infrastructure, previous site activities can add a layer of complexity that must be accounted for when developing groundwater monitoring protection networks. Extensive work has been done on developing monitoring networks at GS sites for CO2 accounting and groundwater protection. However, the development of appropriate monitoring strategies at commercial brownfield sites continues to develop. The goals of this research are to address the added monitoring complexity by adapting simple analytical and numerical models to test these approaches using two common subsurface monitoring parameters, pressure and aqueous geochemistry. The analytical pressure model solves for diffusivity in radial coordinates and the leakage rate derived from Darcy's law. The aqueous geochemical calculation computer program PHREEQC solves the advection-reaction-dispersion equation for 1-D transport and mixing of fluids .The research was conducted at a CO2 enhanced oil recovery (EOR) field on the Gulf Coast of Texas. We modeled the performance over time of one monitoring well from the EOR field using physical and operational data including lithology and water chemistry samples, and formation pressure data. We explored through statistical analyses the probability of leakage detection using the analytical and numerical methods by varying the monitoring well location spatially and vertically with respect to a leaky fault. Preliminary results indicate that a pressure based subsurface monitoring system provides a better probability of leakage detection than geochemistry alone, but together these monitoring parameters can improve the chances of leakage detection

  2. Modal parameter identification under non-stationary ambient excitation based on continuous time AR Model

    Institute of Scientific and Technical Information of China (English)

    DU XiuLi; WANG FengQuan

    2009-01-01

    A new time-domain modal identification method of linear time-lnvariant system driven by the non-stationary Gaussian random excitation is introduced based on the continuous time AR model.The method can identify physical parameters of the system from response data.In order to identify the parameters of the system, the structural dynamic equation is first transformed into the continuous time AR model, and subsequently written into the forms of observation equation and state equation which is just a stochastic differential equation.Secondly, under the assumption that the uniformly modulated function is approximately equal to a constant matrix in a very short time period, the uniformly modulated func-tion is identified piecewise.Then, we present the exact maximum likelihood estimators of parameters by virtue of the Girsanov theorem.Finally, the modal parameters are identified by eigenanalysis.Nu-merical results show that the method we introduce here not only has high precision and robustness, but also has very high computing efficiency.Therefore, it is suitable for real-time modal identification.

  3. Modal parameter identification under non-stationary ambient excitation based on continuous time AR Model

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    A new time-domain modal identification method of linear time-invariant system driven by the non-stationary Gaussian random excitation is introduced based on the continuous time AR model. The method can identify physical parameters of the system from response data. In order to identify the parameters of the system, the structural dynamic equation is first transformed into the continuous time AR model, and subsequently written into the forms of observation equation and state equation which is just a stochastic differential equation. Secondly, under the assumption that the uniformly modulated function is approximately equal to a constant matrix in a very short time period, the uniformly modulated function is identified piecewise. Then, we present the exact maximum likelihood estimators of parameters by virtue of the Girsanov theorem. Finally, the modal parameters are identified by eigenanalysis. Numerical results show that the method we introduce here not only has high precision and robustness, but also has very high computing efficiency. Therefore, it is suitable for real-time modal identification.

  4. Exploring Factor Model Parameters across Continuous Variables with Local Structural Equation Models.

    Science.gov (United States)

    Hildebrandt, Andrea; Lüdtke, Oliver; Robitzsch, Alexander; Sommer, Christopher; Wilhelm, Oliver

    2016-01-01

    Using an empirical data set, we investigated variation in factor model parameters across a continuous moderator variable and demonstrated three modeling approaches: multiple-group mean and covariance structure (MGMCS) analyses, local structural equation modeling (LSEM), and moderated factor analysis (MFA). We focused on how to study variation in factor model parameters as a function of continuous variables such as age, socioeconomic status, ability levels, acculturation, and so forth. Specifically, we formalized the LSEM approach in detail as compared with previous work and investigated its statistical properties with an analytical derivation and a simulation study. We also provide code for the easy implementation of LSEM. The illustration of methods was based on cross-sectional cognitive ability data from individuals ranging in age from 4 to 23 years. Variations in factor loadings across age were examined with regard to the age differentiation hypothesis. LSEM and MFA converged with respect to the conclusions. When there was a broad age range within groups and varying relations between the indicator variables and the common factor across age, MGMCS produced distorted parameter estimates. We discuss the pros of LSEM compared with MFA and recommend using the two tools as complementary approaches for investigating moderation in factor model parameters.

  5. A Random Parameter Model for Continuous-Time Mean-Variance Asset-Liability Management

    Directory of Open Access Journals (Sweden)

    Hui-qiang Ma

    2015-01-01

    Full Text Available We consider a continuous-time mean-variance asset-liability management problem in a market with random market parameters; that is, interest rate, appreciation rates, and volatility rates are considered to be stochastic processes. By using the theories of stochastic linear-quadratic (LQ optimal control and backward stochastic differential equations (BSDEs, we tackle this problem and derive optimal investment strategies as well as the mean-variance efficient frontier analytically in terms of the solution of BSDEs. We find that the efficient frontier is still a parabola in a market with random parameters. Comparing with the existing results, we also find that the liability does not affect the feasibility of the mean-variance portfolio selection problem. However, in an incomplete market with random parameters, the liability can not be fully hedged.

  6. A new permanent multi-parameter monitoring network in Central Asian high mountains – from measurements to data bases

    Directory of Open Access Journals (Sweden)

    T. Schöne

    2013-02-01

    Full Text Available Long-term monitoring of water resources and climate parameters at the scale of river basins requires networks of continuously operated in-situ stations. Since 2009, GFZ and CAIAG, in cooperation with the National Hydrometeorological Services (NHMS of Central Asia, are establishing such a regional monitoring network in Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan, and lately Afghanistan to collect observations of meteorological and hydrological parameters and to deliver them to the end-users for operational tasks and scientific studies. The newly developed and installed remotely operated multi-parameter stations (ROMPS do not only monitor standard meteorological and hydrological parameters, but also deliver Global Navigation Satellite System (GNSS data for atmospheric sounding as well as tectonic studies. Additionally, three stations integrate seismic sensors for earthquake monitoring. The observational data from the ROMPS is transmitted nominally in near-real time, but at least once a day to a centralized geo-database infrastructure for long-term storage and data redistribution. Users can access the data manually using a web-interface or automatically using SOS requests; in addition, data is planed to be distributed to the NHMS through standard communication and data exchange channels.

  7. A new permanent multi-parameter monitoring network in Central Asian high mountains – from measurements to data bases

    Directory of Open Access Journals (Sweden)

    T. Schöne

    2012-06-01

    Full Text Available Long-term monitoring of water resources and climate parameters at the scale of river basins requires networks of continuously operated in-situ stations. Since 2009, GFZ and CAIAG, in cooperation with the National Hydrometeorological Services (NHMS, are establishing such a regional monitoring network in Central Asia (Kazakhstan, Kyrgyzstan, Tajikistan, Uzbekistan, and Afghanistan which is collecting observations of meteorological and hydrological parameters and delivering them to the end-users. The network design focuses mainly on the higher elevations where the recent decline of monitoring stations and networks established in Soviet times was strongest, and the resulting observational gap hinders research on climate and hydrological change as well as operational tasks in water management such as the seasonal runoff forecast. The newly developed and installed Remotely Operated Multi-Parameter Stations (ROMPS do not only monitor standard meteorological and hydrological parameters, but also deliver GPS data for atmospheric sounding as well as tectonic studies. The observational data from the ROMPS is transmitted at least once a day to a centralized geo-database infrastructure for long-term storage and data redistribution. Users can access the data manually using a web-interface or automatically using SOS requests; in addition, data is distributed to the NHMS through standard communication and data exchange channels.

  8. Characterization of Industrial Coolant Fluids and Continuous Ageing Monitoring by Wireless Node-Enabled Fiber Optic Sensors.

    Science.gov (United States)

    Sachat, Alexandros El; Meristoudi, Anastasia; Markos, Christos; Sakellariou, Andreas; Papadopoulos, Aggelos; Katsikas, Serafim; Riziotis, Christos

    2017-03-11

    Environmentally robust chemical sensors for monitoring industrial processes or infrastructures are lately becoming important devices in industry. Low complexity and wireless enabled characteristics can offer the required flexibility for sensor deployment in adaptable sensing networks for continuous monitoring and management of industrial assets. Here are presented the design, development and operation of a class of low cost photonic sensors for monitoring the ageing process and the operational characteristics of coolant fluids used in an industrial heavy machinery infrastructure. The chemical, physical and spectroscopic characteristics of specific industrial-grade coolant fluids were analyzed along their entire life cycle range, and proper parameters for their efficient monitoring were identified. Based on multimode polymer or silica optical fibers, wide range (3-11) pH sensors were developed by employing sol-gel derived pH sensitive coatings. The performances of the developed sensors were characterized and compared, towards their coolants' ageing monitoring capability, proving their efficiency in such a demanding application scenario and harsh industrial environment. The operating characteristics of this type of sensors allowed their integration in an autonomous wireless sensing node, thus enabling the future use of the demonstrated platform in wireless sensor networks for a variety of industrial and environmental monitoring applications.

  9. Characterization of Industrial Coolant Fluids and Continuous Ageing Monitoring by Wireless Node—Enabled Fiber Optic Sensors

    Science.gov (United States)

    El Sachat, Alexandros; Meristoudi, Anastasia; Markos, Christos; Sakellariou, Andreas; Papadopoulos, Aggelos; Katsikas, Serafim; Riziotis, Christos

    2017-01-01

    Environmentally robust chemical sensors for monitoring industrial processes or infrastructures are lately becoming important devices in industry. Low complexity and wireless enabled characteristics can offer the required flexibility for sensor deployment in adaptable sensing networks for continuous monitoring and management of industrial assets. Here are presented the design, development and operation of a class of low cost photonic sensors for monitoring the ageing process and the operational characteristics of coolant fluids used in an industrial heavy machinery infrastructure. The chemical, physical and spectroscopic characteristics of specific industrial-grade coolant fluids were analyzed along their entire life cycle range, and proper parameters for their efficient monitoring were identified. Based on multimode polymer or silica optical fibers, wide range (3–11) pH sensors were developed by employing sol-gel derived pH sensitive coatings. The performances of the developed sensors were characterized and compared, towards their coolants’ ageing monitoring capability, proving their efficiency in such a demanding application scenario and harsh industrial environment. The operating characteristics of this type of sensors allowed their integration in an autonomous wireless sensing node, thus enabling the future use of the demonstrated platform in wireless sensor networks for a variety of industrial and environmental monitoring applications. PMID:28287488

  10. Application of the Continuous-Discrete Extended Kalman Filter for Fault Detection in Continuous Glucose Monitors for Type 1 Diabetes

    DEFF Research Database (Denmark)

    Mahmoudi, Zeinab; Boiroux, Dimitri; Hagdrup, Morten

    2016-01-01

    The purpose of this study is the online detection of faults and anomalies of a continuous glucose monitor (CGM). We simulated a type 1 diabetes patient using the Medtronic virtual patient model. The model is a system of stochastic differential equations and includes insulin pharmacokinetics......, insulin-glucose interaction, and carbohydrate absorption. We simulated and detected two types of CGM faults, i.e., spike and drift. A fault was defined as a CGM value in any of the zones C, D, and E of the Clarke error grid analysis classification. Spike was modelled by a binomial distribution, and drift...... was modelled by a Gaussian random walk. We used a continuous-discrete extended Kalman filter for the fault detection, based on the statistical tests of the filter innovation and the 90-min prediction residuals of the sensor measurements. The spike detection had a sensitivity of 93% and a specificity of 100...

  11. Inference of Soil Hydrologic Parameters from Soil Moisture Monitoring Records

    Science.gov (United States)

    Chandler, D. G.; Seyfried, M. S.; McNamara, J. P.; Hwang, K.

    2015-12-01

    Soil moisture is an important control on hydrologic function, as it governs flux through the soil and responds to and determines vertical fluxes from and to the atmosphere, groundwater recharge and lateral fluxes through the soil. Most physically based hydrologic models require parameters to represent soil physical properties governing flow and retention of vadose water. The presented analysis compares four methods of objective analysis to determine field capacity, plant extraction limit (or permanent wilting point) and field saturated soil moisture content from decadal records of volumetric water content. These values are found as either data attractors or limits in the VWC records and may vary with interannual moisture availability. Results are compared to values from pedotransfer functions and discussed in terms of historic methods of measurement in soil physics.

  12. Continuous multi-parameter heart rate variability analysis heralds onset of sepsis in adults.

    Directory of Open Access Journals (Sweden)

    Saif Ahmad

    Full Text Available BACKGROUND: Early diagnosis of sepsis enables timely resuscitation and antibiotics and prevents subsequent morbidity and mortality. Clinical approaches relying on point-in-time analysis of vital signs or lab values are often insensitive, non-specific and late diagnostic markers of sepsis. Exploring otherwise hidden information within intervals-in-time, heart rate variability (HRV has been documented to be both altered in the presence of sepsis, and correlated with its severity. We hypothesized that by continuously tracking individual patient HRV over time in patients as they develop sepsis, we would demonstrate reduced HRV in association with the onset of sepsis. METHODOLOGY/PRINCIPAL FINDINGS: We monitored heart rate continuously in adult bone marrow transplant (BMT patients (n = 21 beginning a day before their BMT and continuing until recovery or withdrawal (12+/-4 days. We characterized HRV continuously over time with a panel of time, frequency, complexity, and scale-invariant domain techniques. We defined baseline HRV as mean variability for the first 24 h of monitoring and studied individual and population average percentage change (from baseline over time in diverse HRV metrics, in comparison with the time of clinical diagnosis and treatment of sepsis (defined as systemic inflammatory response syndrome along with clinically suspected infection requiring treatment. Of the 21 patients enrolled, 4 patients withdrew, leaving 17 patients who completed the study. Fourteen patients developed sepsis requiring antibiotic therapy, whereas 3 did not. On average, for 12 out of 14 infected patients, a significant (25% reduction prior to the clinical diagnosis and treatment of sepsis was observed in standard deviation, root mean square successive difference, sample and multiscale entropy, fast Fourier transform, detrended fluctuation analysis, and wavelet variability metrics. For infected patients (n = 14, wavelet HRV demonstrated a 25% drop from

  13. Closing the loop from continuous M-health monitoring to fuzzy logic-based optimized recommendations.

    Science.gov (United States)

    Benharref, Abdelghani; Serhani, Mohamed Adel; Nujum, Al Ramzana

    2014-01-01

    Continuous sensing of health metrics might generate a massive amount of data. Generating clinically validated recommendations, out of these data, to patients under monitoring is of prime importance to protect them from risk of falling into severe health degradation. Physicians also can be supported with automated recommendations that gain from historical data and increasing learning cycles. In this paper, we propose a Fuzzy Expert System that relies on data collected from continuous monitoring. The monitoring scheme implements preprocessing of data for better data analytics. However, data analytics implements the loopback feature in order to constantly improve fuzzy rules, knowledge base, and generated recommendations. Both techniques reduced data quantity, improved data quality and proposed recommendations. We evaluate our solution through a series of experiments and the results we have obtained proved that our fuzzy expert system combined with the intelligent monitoring and analytic techniques provide a high accuracy of collected data and valid advices.

  14. Monitoring of solidification in the continuous casting mold by temperature sensors

    Science.gov (United States)

    Pyszko, René; Příhoda, Miroslav; Čarnogurská, Mária

    2016-06-01

    Defects of continuously cast strand, such as unevenness of shell thickness or cracks as well as unstable casting parameters result in changes of strand surface temperature which affect heat flux and temperature field in the mold wall. Methods based on the principle of measurement and mathematical processing of temperatures in the mold wall are used for the purposes of diagnostics of the shell formation process, prediction of surface and subsurface quality and breakout danger, adjustment of the casting axis or condition monitoring of the oscillating mechanism. Measured values of temperatures in the wall depend on the exact position of the sensor in the wall, especially in the normal direction to the mold working surface. Ensuring the accurate and constant distance between the sensor and the mold surface is technically demanding; therefore it is necessary to correct the measured temperatures mathematically. The article describes two methods for correcting the measured temperatures, based on physical and statistical principles that have been developed and used in a real diagnostics system. Practical applications of the methods for diagnostics of strand surface quality and breakout prediction are presented.

  15. Investigating the value of passive microwave observations for monitoring volcanic eruption source parameters

    Science.gov (United States)

    Montopoli, Mario; Cimini, Domenico; Marzano, Frank

    2016-04-01

    Volcanic eruptions inject both gas and solid particles into the Atmosphere. Solid particles are made by mineral fragments of different sizes (from few microns to meters), generally referred as tephra. Tephra from volcanic eruptions has enormous impacts on social and economical activities through the effects on the environment, climate, public health, and air traffic. The size, density and shape of a particle determine its fall velocity and thus residence time in the Atmosphere. Larger particles tend to fall quickly in the proximity of the volcano, while smaller particles may remain suspended for several days and thus may be transported by winds for thousands of km. Thus, the impact of such hazards involves local as well as large scales effects. Local effects involve mostly the large sized particles, while large scale effects are caused by the transport of the finest ejected tephra (ash) through the atmosphere. Forecasts of ash paths in the atmosphere are routinely run after eruptions using dispersion models. These models make use of meteorological and volcanic source parameters. The former are usually available as output of numerical weather prediction models or large scale reanalysis. Source parameters characterize the volcanic eruption near the vent; these are mainly the ash mass concentration along the vertical column and the top altitude of the volcanic plume, which is strictly related to the flux of the mass ejected at the emission source. These parameters should be known accurately and continuously; otherwise, strong hypothesis are usually needed, leading to large uncertainty in the dispersion forecasts. However, direct observations during an eruption are typically dangerous and impractical. Thus, satellite remote sensing is often exploited to monitor volcanic emissions, using visible (VIS) and infrared (IR) channels available on both Low Earth Orbit (LEO) and Geostationary Earth Orbit (GEO) satellites. VIS and IR satellite imagery are very useful to monitor

  16. Exploration of process parameters for continuous hydrolysis of canola oil, camelina oil and algal oil

    KAUST Repository

    Wang, Weicheng

    2012-07-01

    Thermal hydrolysis of triglycerides to form free fatty acid (FFA) is a well-established industry practice. Recently, this process has been employed as a first step in the production of biofuels from lipids. To that end, batch and continuous hydrolysis of various feedstocks has been examined at the laboratory scale. Canola, the primary feedstock in this paper, camelina and algal oils were converted to high quality FFA. For the different reaction temperatures, the continuous hydrolysis system was found to provide better yields than the laboratory batch system. In addition, CFD simulation with ANSYS-CFX was used to model the performance and reactant/product separation in the continuous, counter-flow reactor. The effects of reaction temperature, water-to-oil ratio (ratio of water and oil volumetric inflow rate), and preheating of the reactants were examined experimentally. Optimization of these parameters has resulted in an improved, continuous process with high mass yields (89-93%, for reactor temperature of 260°C and water-to-oil ratio of 4:1) and energy efficiency (76%, for reactor temperature of 250°C and water-to-oil ratio of 2:1). Based on the product quality and energy efficiency considerations, the reactor temperature of 260°C and water-to-oil ratio of 4:1 have provided the optimal condition for the lab scale continuous hydrolysis reaction. © 2012 Elsevier B.V.

  17. Comparison of an advanced minimally invasive cardiac output monitoring with a continuous invasive cardiac output monitoring during lung transplantation.

    Science.gov (United States)

    Tomasi, Roland; Prueckner, Stephan; Czerner, Stephan; Schramm, Renè; Preissler, Gerhard; Zwißler, Bernhard; von Dossow-Hanfstingl, Vera

    2016-08-01

    The aim of this study was to compare a continuous non-calibrated left heart cardiac index (CI) measurement by arterial waveform analysis (FloTrac(®)/Vigileo(®)) with a continuous calibrated right heart CI measurement by pulmonary artery thermodilution (CCOmbo-PAC(®)/Vigilance II(®)) for hemodynamic monitoring during lung transplantation. CI was measured simultaneously by both techniques in 13 consecutive lung transplants (n = 4 single-lung transplants, n = 9 sequential double-lung transplants) at distinct time points perioperatively. Linear regression analysis and Bland-Altman analysis with percentage error calculation were used for statistical comparison of CI measurements by both techniques. In this study the FloTrac(®) system underestimated the CI in comparison with the continuous pulmonary arterial thermodilution (p waveform and continuous pulmonary artery thermodilution are, therefore, not interchangeable during these complex operations.

  18. Parameter-space metric of semicoherent searches for continuous gravitational waves

    Science.gov (United States)

    Pletsch, Holger J.

    2010-08-01

    Continuous gravitational-wave (CW) signals such as emitted by spinning neutron stars are an important target class for current detectors. However, the enormous computational demand prohibits fully coherent broadband all-sky searches for prior unknown CW sources over wide ranges of parameter space and for yearlong observation times. More efficient hierarchical “semicoherent” search strategies divide the data into segments much shorter than one year, which are analyzed coherently; then detection statistics from different segments are combined incoherently. To optimally perform the incoherent combination, understanding of the underlying parameter-space structure is requisite. This problem is addressed here by using new coordinates on the parameter space, which yield the first analytical parameter-space metric for the incoherent combination step. This semicoherent metric applies to broadband all-sky surveys (also embedding directed searches at fixed sky position) for isolated CW sources. Furthermore, the additional metric resolution attained through the combination of segments is studied. From the search parameters (sky position, frequency, and frequency derivatives), solely the metric resolution in the frequency derivatives is found to significantly increase with the number of segments.

  19. Multi-parameter numerical simulation of dynamic monitoring of rock deformation in deep mining

    Institute of Scientific and Technical Information of China (English)

    Li Juanjuan; Hu Mingshun; Ding Enjie; Kong Wei; Pan Dongming; Chen Shenen

    2016-01-01

    The level of deformation development of surrounding rocks is a vital predictor to evaluate impending coal mine disasters and it is important to establish accurate measurements of the deformed status to ensure coal mine safety. Traditional deformation monitoring methods are mostly based on single parameter, in this paper, multiple approaches are integrated: firstly, both electric and elastic models are established, from which electric field distribution and seismic wave recording are calculated and finally, the resistivity profiles and source position information are determined using inversion methods, from which then the deformation and failure of mine floor are evaluated. According to the inversion results of both electric and seismic field signals, multiple-parameter dynamic monitoring of surrounding rock deformation in deep mine can be performed. The methodology is validated using numerical simulation results which shows that the multi-parameter dynamic monitoring methods have better results for surrounding rock deformation in deep mine monitoring than single parameter methods.

  20. Low-Power Wearable Systems for Continuous Monitoring of Environment and Health for Chronic Respiratory Disease.

    Science.gov (United States)

    Dieffenderfer, James; Goodell, Henry; Mills, Steven; McKnight, Michael; Yao, Shanshan; Lin, Feiyan; Beppler, Eric; Bent, Brinnae; Lee, Bongmook; Misra, Veena; Zhu, Yong; Oralkan, Omer; Strohmaier, Jason; Muth, John; Peden, David; Bozkurt, Alper

    2016-09-01

    We present our efforts toward enabling a wearable sensor system that allows for the correlation of individual environmental exposures with physiologic and subsequent adverse health responses. This system will permit a better understanding of the impact of increased ozone levels and other pollutants on chronic asthma conditions. We discuss the inefficiency of existing commercial off-the-shelf components to achieve continuous monitoring and our system-level and nano-enabled efforts toward improving the wearability and power consumption. Our system consists of a wristband, a chest patch, and a handheld spirometer. We describe our preliminary efforts to achieve a submilliwatt system ultimately powered by the energy harvested from thermal radiation and motion of the body with the primary contributions being an ultralow-power ozone sensor, an volatile organic compounds sensor, spirometer, and the integration of these and other sensors in a multimodal sensing platform. The measured environmental parameters include ambient ozone concentration, temperature, and relative humidity. Our array of sensors also assesses heart rate via photoplethysmography and electrocardiography, respiratory rate via photoplethysmography, skin impedance, three-axis acceleration, wheezing via a microphone, and expiratory airflow. The sensors on the wristband, chest patch, and spirometer consume 0.83, 0.96, and 0.01 mW, respectively. The data from each sensor are continually streamed to a peripheral data aggregation device and are subsequently transferred to a dedicated server for cloud storage. Future work includes reducing the power consumption of the system-on-chip including radio to reduce the entirety of each described system in the submilliwatt range.

  1. CGM Versus FGM; or, Continuous Glucose Monitoring Is Not Flash Glucose Monitoring.

    Science.gov (United States)

    Heinemann, Lutz; Freckmann, Guido

    2015-09-01

    It remains to be seen as to what share of the market FGM will achieve if the manufacturer can supply any amount desired.Will a significant portion of the glucose monitoring market then be taken over by FGM? The availability of FGM as anew option for glucose monitoring can basically be evaluated positively and it does indeed clearly show the benefit of“more information” on the glucose trend. The relatively low price for glucose monitoring using FGM and the unusual market introduction (not first via the National Association of Statutory Health Insurance Funds, as was the case with CGM) have given increased attention to the use of more glucose information. It will likely take a certain amount of time before other providers are able to bring different FGM systems to the market.The option of coupling a CGM system with an insulin pump offers the perspective of an automated insulin application,that is, a closed-loop system. Such systems are currently being tested under everyday conditions, although it is not possible to predict when they will actually reach the market.There are, however, such couplings where algorithms are responsible for shutting off insulin delivery when the glucose concentration reaches a defined level or if it will be reached in the foreseeable future. This significantly helps prevent hypoglycemia. These options are only available with CGM. The aim of this commentary is to present the differences between CGM and FGM, including the advantages and disadvantages of both approaches. We see significant benefits in both options based on the different positioning of the approaches and the different user groups.

  2. Multisensor-integrated organs-on-chips platform for automated and continual in situ monitoring of organoid behaviors.

    Science.gov (United States)

    Zhang, Yu Shrike; Aleman, Julio; Shin, Su Ryon; Kilic, Tugba; Kim, Duckjin; Mousavi Shaegh, Seyed Ali; Massa, Solange; Riahi, Reza; Chae, Sukyoung; Hu, Ning; Avci, Huseyin; Zhang, Weijia; Silvestri, Antonia; Sanati Nezhad, Amir; Manbohi, Ahmad; De Ferrari, Fabio; Polini, Alessandro; Calzone, Giovanni; Shaikh, Noor; Alerasool, Parissa; Budina, Erica; Kang, Jian; Bhise, Nupura; Ribas, João; Pourmand, Adel; Skardal, Aleksander; Shupe, Thomas; Bishop, Colin E; Dokmeci, Mehmet Remzi; Atala, Anthony; Khademhosseini, Ali

    2017-03-21

    Organ-on-a-chip systems are miniaturized microfluidic 3D human tissue and organ models designed to recapitulate the important biological and physiological parameters of their in vivo counterparts. They have recently emerged as a viable platform for personalized medicine and drug screening. These in vitro models, featuring biomimetic compositions, architectures, and functions, are expected to replace the conventional planar, static cell cultures and bridge the gap between the currently used preclinical animal models and the human body. Multiple organoid models may be further connected together through the microfluidics in a similar manner in which they are arranged in vivo, providing the capability to analyze multiorgan interactions. Although a wide variety of human organ-on-a-chip models have been created, there are limited efforts on the integration of multisensor systems. However, in situ continual measuring is critical in precise assessment of the microenvironment parameters and the dynamic responses of the organs to pharmaceutical compounds over extended periods of time. In addition, automated and noninvasive capability is strongly desired for long-term monitoring. Here, we report a fully integrated modular physical, biochemical, and optical sensing platform through a fluidics-routing breadboard, which operates organ-on-a-chip units in a continual, dynamic, and automated manner. We believe that this platform technology has paved a potential avenue to promote the performance of current organ-on-a-chip models in drug screening by integrating a multitude of real-time sensors to achieve automated in situ monitoring of biophysical and biochemical parameters.

  3. Modelling of slaughterhouse solid waste anaerobic digestion: determination of parameters and continuous reactor simulation.

    Science.gov (United States)

    López, Iván; Borzacconi, Liliana

    2010-10-01

    A model based on the work of Angelidaki et al. (1993) was applied to simulate the anaerobic biodegradation of ruminal contents. In this study, two fractions of solids with different biodegradation rates were considered. A first-order kinetic was used for the easily biodegradable fraction and a kinetic expression that is function of the extracellular enzyme concentration was used for the slowly biodegradable fraction. Batch experiments were performed to obtain an accumulated methane curve that was then used to obtain the model parameters. For this determination, a methodology derived from the "multiple-shooting" method was successfully used. Monte Carlo simulations allowed a confidence range to be obtained for each parameter. Simulations of a continuous reactor were performed using the optimal set of model parameters. The final steady-states were determined as functions of the operational conditions (solids load and residence time). The simulations showed that methane flow peaked at a flow rate of 0.5-0.8 Nm(3)/d/m(reactor)(3) at a residence time of 10-20 days. Simulations allow the adequate selection of operating conditions of a continuous reactor.

  4. Characterization of a New Continuous Air Monitoring System For the University of Massachusetts Lowell Research Reactor

    Science.gov (United States)

    Alqahtani, Mohammad Saad

    A continuous air monitor (CAM) is a critical piece of equipment to support radiation safety in nuclear facilities where the generation of airborne radioactivity is a possibility for either normal operations or accident scenarios. The University of Massachusetts Lowell Research Reactor is planning to install a new CAM system manufactured by Canberra Industries for monitoring airborne radioactive particulates. In this study, the new CAM was evaluated to determine 1) baseline response, 2) response to high exposure rates, 3) appropriate background compensation, 4) detection limits, and 5) alarm settings. The results of this study will help to properly integrate the new CAM into the reactor radiation monitoring system.

  5. Robust stability test for 2-D continuous-discrete systems with interval parameters

    Institute of Scientific and Technical Information of China (English)

    肖扬

    2004-01-01

    It is revealed that the dynamic stability of 2-D recursive continuous-discrete systems with interval parameters involves the problem of robust Hurwitz-Schur stability of bivariate polynomials family. It is proved that the HurwitzSchur stability of the denominator polynomials of the systems is necessary and sufficient for the asymptotic stability of the 2-D hybrid systems. The 2-D hybrid transformation, i.e. 2-D Laplace-Z transformation, has been proposed to solve the stability analysis of the 2-D continuous-discrete systems, to get the 2-D hybrid transfer functions of the systems. The edge test for the Hurwitz-Schur stability of interval bivariate polynomials is introduced. The Hurwitz-Schur stability of the interval family of 2-D polynomials can be guaranteed by the stability of its finite edge polynomials of the family. An algorithm about the stability test of edge polynomials is given.

  6. An Efficient Finite Difference Method for Parameter Sensitivities of Continuous Time Markov Chains

    CERN Document Server

    Anderson, David F

    2011-01-01

    We present an efficient finite difference method for the computation of parameter sensitivities for a wide class of continuous time Markov chains. The motivating class of models, and the source of our examples, are the stochastic chemical kinetic models commonly used in the biosciences, though other natural application areas include population processes and queuing networks. The method is essentially derived by making effective use of the random time change representation of Kurtz, and is no harder to implement than any standard continuous time Markov chain algorithm, such as "Gillespie's algorithm" or the next reaction method. Further, the method is analytically tractable, and, for a given number of realizations of the stochastic process, produces an estimator with substantially lower variance than that obtained using other common methods. Therefore, the computational complexity required to solve a given problem is lowered greatly. In this work, we present the method together with the theoretical analysis de...

  7. Parameter design and analysis in continuous drive friction welding of Al6061/SiCp composites

    Energy Technology Data Exchange (ETDEWEB)

    Adalrasan, R. [Saveetha Engineering College, Chennai (India); Sundaram, A. Shanmuga [Sree Sastha Institute of Engineering and Technology, Chennai (India)

    2015-02-15

    Continuous drive friction welding (FW) had found profound industrial applications as an economical solid state joining process. The welding parameters such as frictional pressure, upset pressure, burn off length and rotational speed were found to influence the quality of joints. In the present study, Al6061/SiC{sub p} rods were joined by friction welding. The welding trials were designed by using Taguchi's L{sub 9} orthogonal array. Tensile strength and micro hardness of the joints were observed as the quality characteristics after each trial. The urge for parameter design had prompted the disclosure of a new integrated methodology based on technique for order of preference by similarity to ideal solution (TOPSIS) and grey relational analysis (GRA). The effectiveness of the proposed approach of T-GRA was validated by conducting a confirmation test and the field emission scanning electron microscope (FESEM) images of the fractured surface were also examined.

  8. Parameter design and performance analysis of zero inertia continuously variable transmission system

    Institute of Scientific and Technical Information of China (English)

    胡建军; 吉毅; 晏玖江

    2015-01-01

    In order to solve the problem of weak power performance of vehicle equipped with continuously variable transmission (CVT) system working under transient operating conditions, a new CVT equipped with planetary gear mechanism and flywheel was researched, a design method of transmission parameter optimization was proposed, and the comprehensive matching control strategy was established for the new transmission system. Fuzzy controllers for throttle opening and CVT speed ratio were designed, and power performance and fuel economy of both vehicles respectively equipped with conventional CVT system and new transmission system wrere compared and analyzed by simulation. The results show that power performance and fuel economy of the vehicle equipped with new transmission system are better than that equipped with conventional CVT, thus the rationality of the parameter design method and control algorithm are verified.

  9. Calculating kinetics parameters and reactivity changes with continuous-energy Monte Carlo

    Energy Technology Data Exchange (ETDEWEB)

    Kiedrowski, Brian C [Los Alamos National Laboratory; Brown, Forrest B [Los Alamos National Laboratory; Wilson, Paul [UNIV. WISCONSIN

    2009-01-01

    The iterated fission probability interpretation of the adjoint flux forms the basis for a method to perform adjoint weighting of tally scores in continuous-energy Monte Carlo k-eigenvalue calculations. Applying this approach, adjoint-weighted tallies are developed for two applications: calculating point reactor kinetics parameters and estimating changes in reactivity from perturbations. Calculations are performed in the widely-used production code, MCNP, and the results of both applications are compared with discrete ordinates calculations, experimental measurements, and other Monte Carlo calculations.

  10. On-line parameter and delay estimation of continuous-time dynamic systems

    Directory of Open Access Journals (Sweden)

    Kozłowski Janusz

    2015-06-01

    Full Text Available The problem of on-line identification of non-stationary delay systems is considered. The dynamics of supervised industrial processes are usually modeled by ordinary differential equations. Discrete-time mechanizations of continuous-time process models are implemented with the use of dedicated finite-horizon integrating filters. Least-squares and instrumental variable procedures mechanized in recursive forms are applied for simultaneous identification of input delay and spectral parameters of the system models. The performance of the proposed estimation algorithms is verified in an illustrative numerical simulation study.

  11. On Compressed Sensing and the Estimation of Continuous Parameters From Noisy Observations

    DEFF Research Database (Denmark)

    Nielsen, Jesper Kjær; Christensen, Mads Græsbøll; Jensen, Søren Holdt

    2012-01-01

    Compressed sensing (CS) has in recent years become a very popular way of sampling sparse signals. This sparsity is measured with respect to some known dictionary consisting of a finite number of atoms. Most models for real world signals, however, are parametrised by continuous parameters......-Rao lower bound (CRLB) which is frequently used for benchmarking the estimation accuracy of unbiased estimators. For the popular sensing matrices such as the Gaussian sensing matrix, our analysis shows that compressed sensing on average degrades the estimation accuracy by at least the down-sample factor....

  12. A continuous hyperspatial monitoring system of evapotranspiration and gross primary productivity from Unmanned Aerial Systems

    Science.gov (United States)

    Wang, Sheng; Bandini, Filippo; Jakobsen, Jakob; Zarco-Tejada, Pablo J.; Köppl, Christian Josef; Haugård Olesen, Daniel; Ibrom, Andreas; Bauer-Gottwein, Peter; Garcia, Monica

    2017-04-01

    Unmanned Aerial Systems (UAS) can collect optical and thermal hyperspatial (signatures of the land surface, closely linked with the vegetation structure and functioning, are already part of models to predict Evapotranspiration (ET) and Gross Primary Productivity (GPP) from satellites. However, there remain challenges for an operational monitoring using UAS compared to satellites: the payload capacity of most commercial UAS is less than 2 kg, but miniaturized sensors have low signal to noise ratios and small field of view requires mosaicking hundreds of images and accurate orthorectification. In addition, wind gusts and lower platform stability require appropriate geometric and radiometric corrections. Finally, modeling fluxes on days without images is still an issue for both satellite and UAS applications. This study focuses on designing an operational UAS-based monitoring system including payload design, sensor calibration, based on routine collection of optical and thermal images in a Danish willow field to perform a joint monitoring of ET and GPP dynamics over continuous time at daily time steps. The payload (digital camera (Sony RX-100) used to retrieve accurate digital elevation models (DEMs) for multispectral and thermal image orthorectification, and a standard GNSS single frequency receiver (UBlox) or a real time kinematic double frequency system (Novatel Inc. flexpack6+OEM628). Geometric calibration of the digital and multispectral cameras was conducted to recover intrinsic camera parameters. After geometric calibration, accurate DEMs with vertical errors about 10cm could be retrieved. Radiometric calibration for the multispectral camera was conducted with an integrating sphere (Labsphere CSTM-USS-2000C) and the laboratory calibration showed that the camera measured radiance had a bias within ±4.8%. The thermal camera was calibrated using a black body at varying target and ambient temperatures and resulted in laboratory accuracy with RMSE of 0.95 K. A

  13. Modeling and Parameter Identification Involving 3-Hydroxypropionaldehyde Inhibitory Effects in Glycerol Continuous Fermentation

    Directory of Open Access Journals (Sweden)

    Zhaohua Gong

    2012-01-01

    Full Text Available Mathematical modeling and parameter estimation are critical steps in the optimization of biotechnological processes. In the 1,3-propanediol (1,3-PD production by glycerol fermentation process under anaerobic conditions, 3-hydroxypropionaldehyde (3-HPA accumulation would arouse an irreversible cessation of the fermentation process. Considering 3-HPA inhibitions to cells growth and to activities of enzymes, we propose a novel mathematical model to describe glycerol continuous cultures. Some properties of the above model are discussed. On the basis of the concentrations of extracellular substances, a parameter identification model is established to determine the kinetic parameters in the presented system. Through the penalty function technique combined with an extension of the state space method, an improved genetic algorithm is then constructed to solve the parameter identification model. An illustrative numerical example shows the appropriateness of the proposed model and the validity of optimization algorithm. Since it is difficult to measure the concentrations of intracellular substances, a quantitative robustness analysis method is given to infer whether the model is plausible for the intracellular substances. Numerical results show that the proposed model is of good robustness.

  14. 40 CFR 60.1240 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Science.gov (United States)

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.1240 Section 60.1240 Protection of Environment... Continuous Emission Monitoring § 60.1240 How do I make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your...

  15. 40 CFR 60.1730 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Science.gov (United States)

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.1730 Section 60.1730 Protection of Environment... continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen (or carbon...

  16. 40 CFR 62.15185 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Science.gov (United States)

    2010-07-01

    ... emission monitoring systems are operating correctly? 62.15185 Section 62.15185 Protection of Environment... make sure my continuous emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure oxygen...

  17. Animal based parameters are no panacea for on-farm monitoring of animal welfare

    NARCIS (Netherlands)

    Bracke, M.B.M.

    2007-01-01

    On-farm monitoring of animal welfare is an important, present-day objective in animal welfare science. Scientists tend to focus exclusively on animal-based parameters, possibly because using environment-based parameters could be begging the question why welfare has been affected and because animal-b

  18. 77 FR 8209 - Quality Assurance Requirements for Continuous Opacity Monitoring Systems at Stationary Sources

    Science.gov (United States)

    2012-02-14

    ... AGENCY 40 CFR Part 60 RIN 2060-AH23 Quality Assurance Requirements for Continuous Opacity Monitoring... standards as specified in federally enforceable regulations. The quality assurance requirements will be... standards to the quality assurance requirements in Appendix F of 40 CFR Part 60 in the ``Rules and...

  19. Continuous water-quality monitoring to improve lake management at Lake Mattamuskeet National Wildlife Refuge

    Science.gov (United States)

    Michelle Moorman; Tom Augspurger

    2016-01-01

    The U.S. Fish and Wildlife Service has partnered with U.S. Geological Survey to establish 2 continuous water-quality monitoring stations at Lake Mattamuskeet. Stations on the east and west side of the lake measure water level, clarity, dissolved oxygen, pH, temperature, salinity, and conductivity.

  20. TESTING THE ACCURACY OF MEASURED VALUES IN CONTINUOUS LONG-TERM GEODETIC MONITORING

    Directory of Open Access Journals (Sweden)

    Jan Vaněček

    2016-12-01

    Full Text Available widespread used method. In this paper, an analysis of the accuracy and its changes over time of the measured values in continuous geodetic monitoring is presented. For the analysis, a set of data measured in the period of time between January 2006 to July 2010 was used. The main method of the analysis is a linear-harmonic function approximation.

  1. 40 CFR Table 6 to Subpart Jjj of... - Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart JJJ of Part 62 Protection of Environment... Combustion Units Constructed on or Before August 30, 1999 Pt. 62, Subpt. JJJ, Table 6 Table 6 to Subpart JJJ...

  2. 40 CFR Table 7 to Subpart Jjj of... - Requirements for Continuous Emission Monitoring Systems (CEMS) a

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Requirements for Continuous Emission Monitoring Systems (CEMS) a 7 Table 7 to Subpart JJJ of Part 62 Protection of Environment ENVIRONMENTAL... Constructed on or Before August 30, 1999 Pt. 62, Subpt. JJJ, Table 7 Table 7 to Subpart JJJ of Part 62...

  3. Exercise strategies to optimize glycemic control in type 2 diabetes : a continuing glucose monitoring perspective

    NARCIS (Netherlands)

    van Dijk, Jan-Willem; van Loon, Luc J C

    2015-01-01

    IN BRIEF The introduction of continuous glucose monitoring (CGM) several years ago enabled researchers to investigate the impact of exercise strategies on 24-hour glycemic control. Such unique information on the glucoregulatory properties of exercise will ultimately lead to more effective exercise p

  4. Continuous EEG monitoring in the intensive care unit: beta scientific and management scientific aspects

    NARCIS (Netherlands)

    Sanders, P.M.H.; van Putten, M.J.A.M.; Jarm, T.; Kramar, P.; Zupanic, A.

    2007-01-01

    Due to various technological advances, it is now possible to continuously monitor critically ill patients using EEG, including the extraction of various quantitative features. In this study, several beta scientific and management scientific aspects of the implementation and use of cEEg on the ICU wi

  5. Scalable Continuous Range Monitoring of Moving Objects in Symbolic Indoor Space

    DEFF Research Database (Denmark)

    Yang, Bin; Lu, Hua; Jensen, Christian Søndergaard

    2009-01-01

    Indoor spaces accommodate large populations of individuals. The continuous range monitoring of such objects can be used as a foundation for a wide variety of applications, e.g., space planning, way finding, and security. Indoor space differs from outdoor space in that symbolic locations, e.g., ro...

  6. Methodological aspects of glucose monitoring with a slow continuous subcutaneous and intravenous ultrafiltration system in rats

    NARCIS (Netherlands)

    Kaptein, WA; Kemper, RHA; Ruiters, MHJ; Venema, K; Tiessen, RG; Korf, J

    1997-01-01

    A method for the continuous ultrafiltration of venous blood or subcutaneous fluid is demonstrated with glucose monitoring in the living rat. Ultrafiltrate was withdrawn at a constant flow rate of approximately 100 nl/min. Glucose content of the ultrafiltrates was electrochemically determined with a

  7. Continuous EEG monitoring in the intensive care unit: beta scientific and management scientific aspects

    NARCIS (Netherlands)

    Sanders, P.M.H.; van Putten, Michel Johannes Antonius Maria; Jarm, T.; Kramar, P.; Zupanic, A.

    2007-01-01

    Due to various technological advances, it is now possible to continuously monitor critically ill patients using EEG, including the extraction of various quantitative features. In this study, several beta scientific and management scientific aspects of the implementation and use of cEEg on the ICU

  8. Derivation of continuous air monitor equations for DAC and DAC-h.

    Science.gov (United States)

    Justus, Alan L

    2010-05-01

    Equations are derived that provide the numerical algorithms necessary for the calculations of both concentration (such as #DAC) and exposure (such as #DAC-h) within continuous air monitors (CAMs) employing collection media. Both calculations utilize measured counts over certain CAM counting intervals. The relationship to similar, although oft misinterpreted, equations given in International Organization for Standardization Standard 11929-5:2005 is detailed.

  9. Accuracy evaluation of a new real-time continuous glucose monitoring algorithm in hypoglycemia

    DEFF Research Database (Denmark)

    Mahmoudi, Zeinab; Jensen, Morten Hasselstrøm; Johansen, Mette Dencker;

    2014-01-01

    UNLABELLED: Abstract Background: The purpose of this study was to evaluate the performance of a new continuous glucose monitoring (CGM) calibration algorithm and to compare it with the Guardian(®) REAL-Time (RT) (Medtronic Diabetes, Northridge, CA) calibration algorithm in hypoglycemia. SUBJECTS...

  10. Novel online sensor technology for continuous monitoring of milk coagulation and whey separation in cheesemaking.

    Science.gov (United States)

    Fagan, Colette C; Castillo, Manuel; Payne, Fred A; O'Donnell, Colm P; Leedy, Megan; O'Callaghan, Donal J

    2007-10-31

    The cheese industry has continually sought a robust method to monitor milk coagulation. Measurement of whey separation is also critical to control cheese moisture content, which affects quality. The objective of this study was to demonstrate that an online optical sensor detecting light backscatter in a vat could be applied to monitor both coagulation and syneresis during cheesemaking. A prototype sensor having a large field of view (LFV) relative to curd particle size was constructed. Temperature, cutting time, and calcium chloride addition were varied to evaluate the response of the sensor over a wide range of coagulation and syneresis rates. The LFV sensor response was related to casein micelle aggregation and curd firming during coagulation and to changes in curd moisture and whey fat contents during syneresis. The LFV sensor has potential as an online, continuous sensor technology for monitoring both coagulation and syneresis during cheesemaking.

  11. Continuous monitoring of snowpack displacement at high spatial and temporal resolution with terrestrial radar interferometry

    Science.gov (United States)

    Caduff, Rafael; Wiesmann, Andreas; Bühler, Yves; Pielmeier, Christine

    2015-02-01

    Terrestrial radar interferometry is used in geotechnical applications for monitoring hazardous Earth or rock movements. In this study, we use it to continuously monitor snowpack displacements. As test site, the Dorfberg slope at Davos, Switzerland, was measured continuously during March 2014. The line of sight displacement was retrieved at a spatial resolution of millimeter to centimeter and a temporal resolution of up to 1 min independent of visibility. The results reveal several temperature-driven diurnal acceleration and deceleration cycles. The initiation of a small full-depth glide avalanche was observed after 50 cm total differential displacement. The maximum measured displacement of another differential glide area reached 43 cm/h without resulting in a full-depth avalanche even after a total measured differential displacement of 4.5 m. In regard of the difficulty to predict full-depth glide avalanches on the regional scale, the presented method has big potential for operational snow glide monitoring on critical slopes.

  12. Increasing the Performance and Reliability of Power Boiler by Monitoring Thermal and Strength Parameters

    Directory of Open Access Journals (Sweden)

    Sobota Tomasz

    2017-01-01

    Full Text Available The paper presents a method for determination of thermo-flow parameters for steam boilers. This method allows to perform the calculations of the boiler furnace chamber and heat flow rates absorbed by superheater stages. These parameters are important for monitoring the performance of the power unit. Knowledge of these parameters allows determining the degree of the furnace chamber slagging. The calculation can be performed in online mode and use to monitoring of steam boiler. The presented method allows to the operation of steam boiler with high efficiency.

  13. Implantable loop recorder monitoring after concomitant surgical ablation for atrial fibrillation (AF): insights from more than 200 continuously monitored patients.

    Science.gov (United States)

    Pecha, Simon; Aydin, Muhammet Ali; Ahmadzade, Teymour; Hartel, Friederike; Hoffmann, Boris; Steven, Daniel; Willems, Stephan; Reichenspurner, Hermann; Wagner, Florian Mathias

    2016-08-01

    Different follow-up methods have been used to report success rates after AF ablation. Recent studies have shown that intermittent rhythm monitoring underestimates the actual AF recurrence rate. We therefore report our experience with continuous rhythm monitoring by implantable loop recorder (ILR) in a large patient cohort. Between 09/2008 and 12/2012, 343 cardiac surgical patients underwent concomitant surgical AF ablation. ILR implantation was performed in 206 patients. ILR interrogation was accomplished at 3, 6 and 12 months postoperatively. Successful ablation was defined as AF Burden <0.5 %. Primary outcome of the study was freedom from AF at 12-month follow-up. Mean patient's age was 70.5 ± 7.4 years. No major ablation- or ILR-related complications occurred. In 4 patients (1.9 %) ILR had to be explanted due to ILR-related wound infection (n = 2) or chronic pain (n = 2). Survival rate at 1-year follow-up was 96.6 %. Freedom from AF rate after 1-year follow-up was 68.5 and 63.6 % off antiarrhythmic drugs, respectively. Statistically significant predictors for successful ablation at 1-year follow-up were smaller LA diameter, shorter duration of AF and preoperative paroxysmal AF. Demographic data, indication for surgery, lesion set and used energy source had no impact on freedom from AF after 1 year. Continuous ILR monitoring after concomitant surgical AF ablation was safe and feasible, with registered freedom from AF rate of 68.5 % at 1-year follow-up. Thus continuous rhythm monitoring provides reliable outcome data and helps to guide antiarrhythmic therapy.

  14. Extraction of Continuous Fiber from Mengkuang Leaves: The Influence of Process Parameters during Alkaline Treatment

    Directory of Open Access Journals (Sweden)

    Hamizol Muhammad Syahmi

    2014-07-01

    Full Text Available Currently, natural cellulose fiber composite is a promising prospect in the composite world. However, achieving uniform strength in natural fiber composite is a challenge due to limited fiber length and its random orientation in the composite. Thus, the focus of this paper was to obtain a continuous cellulose fiber from mengkuang leaves using chemical extraction process. The chemical extraction involved alkaline treatment of the mengkuang leave followed by bleaching. This paper focused on extraction using sodium hydroxide (NaOH and its process parameters. The process parameters of the extraction were varied in terms of concentration of NaOH solution and also the soaking time. The texture and structure of the chemically purified continuous cellulose fiber were observed by visual inspection. Detailed microstructural analysis was carried out using Field Emission Scanning Electron Microscopy (FESEM while chemical composition analysis in term of cellulose percentage was conducted using Technical Association of the Pulp and Paper Industry (TAPPI; TAPPI T203. Preliminary results showed that increment in cellulose percentage when the concentration of NaOH and soaking time were increased.

  15. 40 CFR Table 6 to Subpart Bbbb of... - Model Rule-Requirements for Validating Continuous Emission Monitoring Systems (CEMS)

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Model Rule-Requirements for Validating Continuous Emission Monitoring Systems (CEMS) 6 Table 6 to Subpart BBBB of Part 60 Protection of Environment...—Requirements for Validating Continuous Emission Monitoring Systems (CEMS) For the following continuous...

  16. Monitoring a 5 MW offshore wind energy converter—Condition parameters and triangulation based extraction of modal parameters

    Science.gov (United States)

    Häckell, Moritz W.; Rolfes, Raimund

    2013-10-01

    The test field alpha ventus is the first operating German offshore parks for wind energy. Twelve Wind Energy Converters (WECs) of the 5 MW-class are installed, both, for commercial and research reasons. Due to upcoming mass production and uncertainties in loads and behaviour, monitoring the foundation of these structures was desired. Two goals addressed are the extraction of modal parameters for model validation and the estimation of condition parameters to allow a hypothesis of the system's state. In a first step the largedatabase is classified by Environmental and Operational Conditions (EOCs) through affinity propagation which is a new approach for Structural Health Monitoring (SHM) on wind turbines. Further, system identification through data driven stochastic subspace identification (SSI) is performed. A new, automated approach called triangulation-based extraction of modal parapeters (TEMP), using stability diagrams, is a key focus of the presented research. Finally, extraction of condition parameters for tower accelerations classified by EOCs, based on covariance driven SSI and Vector Auto-Regressive (VAR) Models, is performed for several observation periods from one to 16 weeks. These parameters and their distributions provide a base line for long term observations.

  17. The Effects of Continuous Vs. Intermittent Self-Monitoring on the Duration and Magnitude of Behavior Change.

    Science.gov (United States)

    Schayer, Laurel L.; Schroeder, Harold E.

    Continuous self-monitoring (CSM) was compared with a demand characteristics control condition (non self-monitoring), with intermittent self-monitoring (ISM) and with another control condition. It was predicted that both self-monitoring conditions would produce effects over and above the demand characteristics inherent in the self-monitoring…

  18. Continuous monitoring of bacterial biofilm growth using uncoated Thickness-Shear Mode resonators

    Science.gov (United States)

    Castro, P.; Resa, P.; Durán, C.; Maestre, J. R.; Mateo, M.; Elvira, L.

    2012-12-01

    Quartz Crystal Microbalances (QCM) were used to nondestructively monitor in real time the microbial growth of the bacteria Staphylococcus epidermidis (S. epidermidis) in a liquid broth. QCM, sometimes referred to as Thickness-Shear Mode (TSM) resonators, are highly sensitive sensors not only able to measure very small mass, but also non-gravimetric contributions of viscoelastic media. These devices can be used as biosensors for bacterial detection and are employed in many applications including their use in the food industry, water and environment monitoring, pharmaceutical sciences and clinical diagnosis. In this work, three strains of S. epidermidis (which differ in the ability to produce biofilm) have been continuously monitored using an array of piezoelectric TSM resonators, at 37 °C in a selective culturing media. Microbial growth was followed by measuring the changes in the crystal resonant frequency and bandwidth at several harmonics. It was shown that microbial growth can be monitored in real time using multichannel and multiparametric QCM sensors.

  19. Continuous melt granulation: Influence of process and formulation parameters upon granule and tablet properties.

    Science.gov (United States)

    Monteyne, Tinne; Vancoillie, Jochem; Remon, Jean-Paul; Vervaet, Chris; De Beer, Thomas

    2016-10-01

    The pharmaceutical industry has a growing interest in alternative manufacturing models allowing automation and continuous production in order to improve process efficiency and reduce costs. Implementing a switch from batch to continuous processing requires fundamental process understanding and the implementation of quality-by-design (QbD) principles. The aim of this study was to examine the relationship between formulation-parameters (type binder, binder concentration, drug-binder miscibility), process-parameters (screw speed, powder feed rate and granulation temperature), granule properties (size, size distribution, shape, friability, true density, flowability) and tablet properties (tensile strength, friability, dissolution rate) of four different drug-binder formulations using Design of experiments (DOE). Two binders (polyethylene glycol (PEG) and Soluplus®) with a different solid state, semi-crystalline vs amorphous respectively, were combined with two model-drugs, metoprolol tartrate (MPT) and caffeine anhydrous (CAF), both having a contrasting miscibility with the binders. This research revealed that the granule properties of miscible drug-binder systems depended on the powder feed rate and barrel filling degree of the granulator whereas the granule properties of immiscible systems were mainly influenced by binder concentration. Using an amorphous binder, the tablet tensile strength depended on the granule size. In contrast, granule friability was more important for tablet quality using a brittle binder. However, this was not the case for caffeine-containing blends, since these phenomena were dominated by the enhanced compression properties of caffeine Form I, which was formed during granulation. Hence, it is important to gain knowledge about formulation behavior during processing since this influences the effect of process parameters onto the granule and tablet properties.

  20. Continuous ECG Monitoring in Patients With Acute Coronary Syndrome or Heart Failure: EASI Versus Gold Standard.

    Science.gov (United States)

    Lancia, Loreto; Toccaceli, Andrea; Petrucci, Cristina; Romano, Silvio; Penco, Maria

    2017-04-01

    The purpose of the study was to compare the EASI system with the standard 12-lead surface electrocardiogram (ECG) for the accuracy in detecting the main electrocardiographic parameters (J point, PR, QT, and QRS) commonly monitored in patients with acute coronary syndromes or heart failure. In this observational comparative study, 253 patients who were consecutively admitted to the coronary care unit with acute coronary syndrome or heart failure were evaluated. In all patients, two complete 12-lead ECGs were acquired simultaneously. A total of 6,072 electrocardiographic leads were compared (3,036 standard and 3,036 EASI). No significant differences were found between the investigate parameters of the two measurement methods, either in patients with acute coronary syndrome or in those with heart failure. This study confirmed the accuracy of the EASI system in monitoring the main ECG parameters in patients admitted to the coronary care unit with acute coronary syndrome or heart failure.

  1. Real time continuous oxygen concentration monitoring system during malaxation for the production of Virgin Olive Oil

    Directory of Open Access Journals (Sweden)

    Aiello, G.

    2012-10-01

    Full Text Available During the mechanical extraction process of Virgin Olive Oil (VOO some important physical phenomena and enzymatic transformations occur which influence the quality of the final product. The control of process parameters is crucial to ensure the quality of VOO, therefore process monitoring and control is a fundamental requirement in the modern VOO processing industry. The present work proposes an innovative Real-Time Monitoring System (RTMS aimed at continuously measuring the oxygen concentration during the malaxation process in order to establish a correlation with the quality of the final product obtained. This monitoring system is based on an oxygen concentration sensor directly connected to the malaxation chamber and a data acquisition system to analyze and store the measured values in a process database. The experimental results obtained show that the use of oxygen during malaxation improves some qualitative parameters of VOO such as free fatty acids and total polyphenols while others (peroxide values and spectrophotometric indexes worsen. These results are similar to those obtained by employing nitrogen, which is the traditional technique to avoid the wellknown oxidation processes studied by several researchers, thus demonstrating that the presence of oxygen during the malaxation process can have beneficial effects on the quality of VOO when its concentration is properly controlled.

    Durante el proceso de extracción mecánica del aceite de oliva virgen ocurren importantes fenómenos físicos y transformaciones enzimáticas que influyen en la calidad del producto final. El control de los parámetros del proceso es crucial para garantizar la calidad del aceite de oliva virgen, por tanto la monitorización y el control del proceso son requisitos fundamentales en el moderno tratamiento industrial del aceite de oliva virgen. El presente trabajo propone un sistema de monitorización innovador en tiempo real dirigido a medir continuamente

  2. Monitoring of Physiological Parameters to Predict Exacerbations of Chronic Obstructive Pulmonary Disease (COPD: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Ahmed M. Al Rajeh

    2016-11-01

    Full Text Available Introduction: The value of monitoring physiological parameters to predict chronic obstructive pulmonary disease (COPD exacerbations is controversial. A few studies have suggested benefit from domiciliary monitoring of vital signs, and/or lung function but there is no existing systematic review. Objectives: To conduct a systematic review of the effectiveness of monitoring physiological parameters to predict COPD exacerbation. Methods: An electronic systematic search compliant with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA guidelines was conducted. The search was updated to April 6, 2016. Five databases were examined: Medical Literature Analysis and Retrieval System Online, or MEDLARS Online (Medline, Excerpta Medica dataBASE (Embase, Allied and Complementary Medicine Database (AMED, Cumulative Index of Nursing and Allied Health Literature (CINAHL and the Cochrane clinical trials database. Results: Sixteen articles met the pre-specified inclusion criteria. Fifteen of these articules reported positive results in predicting COPD exacerbation via monitoring of physiological parameters. Nine studies showed a reduction in peripheral oxygen saturation (SpO2% prior to exacerbation onset. Three studies for peak flow, and two studies for respiratory rate reported a significant variation prior to or at exacerbation onset. A particular challenge is accounting for baseline heterogeneity in parameters between patients. Conclusion: There is currently insufficient information on how physiological parameters vary prior to exacerbation to support routine domiciliary monitoring for the prediction of exacerbations in COPD. However, the method remains promising.

  3. An automatic continuous monitoring station for groundwater geochemistry at an active fault zone in SW Taiwan

    Science.gov (United States)

    Lai, Chun-Wei; Yang, Tsanyao F.; Fu, Ching-Chou; Hilton, David R.; Liu, Tsung-Kwei; Walia, Vivek; Lai, Tzu-Hua

    2015-04-01

    Previous studies have revealed that gas compositions of fluid samples collected from southwestern Taiwan where many hot springs and mud volcanoes are distributed along tectonic sutures show significant variation prior to and after some disaster seismic events. Such variations, including radon activity, CH4/CO2, CO2/3He and 3He/4He ratios of gas compositions, are considered to be precursors of earthquakes in this area. To validate the relationship between fluid compositions and local earthquakes, a continuous monitoring station has been established at Yun-Shui, which is an artesian well located at an active fault zone in SW Taiwan. It is equipped with a radon detector and a quadrupole mass spectrometer (QMS) for in-situ measurement of the dissolved gas composition. Data is telemetered to Taipei so we are able to monitor variations of gas composition in real time. Furthermore, we also installed a syringe pump apparatus for the retrieval and temporal analysis of helium (SPARTAH) at this station. From the SPARTAH samples, we can obtain detailed time series records of H-O isotopic compositions, DIC concentration and δ13C isotopic ratios, and anion concentration of the water samples at this station. After continuous monitoring for about one year, some anomalies occurred prior to some local earthquakes. It demonstrates that this automated system is feasible for long-term continuous seismo-geochemical research in this area. Keywords: monitoring; geochemistry; isotope; dissolved gases; pre-seismic signal.

  4. Novel optoacoustic system for noninvasive continuous monitoring of cerebral venous blood oxygenation

    Science.gov (United States)

    Petrov, Yuriy; Petrov, Irene Y.; Prough, Donald S.; Esenaliev, Rinat O.

    2012-02-01

    Traumatic brain injury (TBI) and spinal cord injury are a major cause of death for individuals under 50 years of age. In the USA alone, 150,000 patients per year suffer moderate or severe TBI. Moreover, TBI is a major cause of combatrelated death. Monitoring of cerebral venous blood oxygenation is critically important for management of TBI patients because cerebral venous blood oxygenation below 50% results in death or severe neurologic complications. At present, there is no technique for noninvasive, accurate monitoring of this clinically important variable. We proposed to use optoacoustic technique for noninvasive monitoring of cerebral venous blood oxygenation by probing cerebral veins such as the superior sagittal sinus (SSS) and validated it in animal studies. In this work, we developed a novel, medical grade optoacoustic system for continuous, real-time cerebral venous blood oxygenation monitoring and tested it in human subjects at normal conditions and during hyperventilation to simulate changes that may occur in patients with TBI. We designed and built a highly-sensitive optoacoustic probe for SSS signal detection. Continuous measurements were performed in the near infrared spectral range and the SSS oxygenation absolute values were automatically calculated in real time using a special algorithm developed by our group. Continuous measurements performed at normal conditions and during hyperventilation demonstrated that hyperventilation resulted in approximately 12% decrease of cerebral venous blood oxygenation.

  5. Combined Earth orientation parameters based on homogeneous and continuous VLBI and GPS data

    Science.gov (United States)

    Thaller, Daniela; Krügel, Manuela; Rothacher, Markus; Tesmer, Volker; Schmid, Ralf; Angermann, Detlef

    2007-06-01

    The CONT02 campaign is of great interest for studies combining very long baseline interferometry (VLBI) with other space-geodetic techniques, because of the continuously available VLBI observations over 2 weeks in October 2002 from a homogeneous network. Especially, the combination with the Global Positioning System (GPS) offers a broad spectrum of common parameters. We combined station coordinates, Earth orientation parameters (EOPs) and troposphere parameters consistently in one solution using technique- specific datum-free normal equation systems. In this paper, we focus on the analyses concerning the EOPs, whereas the comparison and combination of the troposphere parameters and station coordinates are covered in a companion paper in Journal of Geodesy. In order to demonstrate the potential of the VLBI and GPS space-geodetic techniques, we chose a sub-daily resolution for polar motion (PM) and universal time (UT). A consequence of this solution set-up is the presence of a one-to-one correlation between the nutation angles and a retrograde diurnal signal in PM. The Bernese GPS Software used for the combination provides a constraining approach to handle this singularity. Simulation studies involving both nutation offsets and rates helped to get a deeper understanding of this singularity. With a rigorous combination of UT1 UTC and length of day (LOD) from VLBI and GPS, we showed that such a combination works very well and does not suffer from the systematic effects present in the GPS-derived LOD values. By means of wavelet analyses and the formal errors of the estimates, we explain this important result. The same holds for the combination of nutation offsets and rates. The local geodetic ties between GPS and VLBI antennas play an essential role within the inter-technique combination. Several studies already revealed non-negligible discrepancies between the terrestrial measurements and the space-geodetic solutions. We demonstrate to what extent these discrepancies

  6. Benefits of blinded continuous glucose monitoring during a randomized clinical trial.

    Science.gov (United States)

    Muchmore, Douglas; Sharp, Melissa; Vaughn, Daniel

    2011-05-01

    Real-time, personal continuous glucose monitoring (CGM) is a validated technology that can help patients improve glycemic control. Blinded CGM is a promising technology for obtaining retrospective data in clinical research where the quantity and quality of blood glucose information is important. This study was designed to investigate the use of novel procedures to enhance data capture from blinded CGM. Following a 4-week run-in, 46 patients with type 1 diabetes were randomized to one of two prandial insulins for a 12-week treatment period, after which they were crossed over to the alternate treatment for 12 weeks. Continuous glucose monitoring was implemented at the end of run-in (practice only) and during the last 2 weeks of each treatment period. Eighty percent of 288 possible daily glucose values were required for at least three days. Continuous glucose monitoring was extended for an additional week if these criteria were not met, and patients were allowed to insert sensors at home when necessary. Continuous glucose monitoring results were compared to reference eight-point self-monitoring of blood glucose (SMBG). Higher than expected sensor failure rate was approximately 25%. During run-in, 12 of 45 attempted profiles failed adequacy criteria. However, treatment periods had only 1 of 82 attempted profiles considered inadequate (6 cases required an additional week of CGM). Using SMBG as reference, 93.7% of 777 CGM values were in Clarke error grid zones A+B. With appropriate training, adequate practice, and opportunity to repeat blinded CGM as needed, nearly 100% of attempted profiles can be obtained successfully. © 2011 Diabetes Technology Society.

  7. OFSETH: smart medical textile for continuous monitoring of respiratory motions under magnetic resonance imaging.

    Science.gov (United States)

    De Jonckheere, J; Narbonneau, F; Jeanne, M; Kinet, D; Witt, J; Krebber, K; Paquet, B; Depre, A; Logier, R

    2009-01-01

    The potential impact of optical fiber sensors embedded into medical textiles for the continuous monitoring of the patient during Magnetic Resonance Imaging is presented. We report on two pure optical sensing technologies for respiratory movements monitoring - a macro bending sensor and a Bragg grating sensor, designed to measure the elongation due to abdominal and thoracic motions during breathing. We demonstrate that the two sensors can successfully sense textile elongation between, 0% and 3%, while maintaining the stretching properties of the textile substrates for a good comfort of the patient.

  8. Capacitive sensor for continuous monitoring of high-volume droplet microfluidic generation

    KAUST Repository

    Conchouso Gonzalez, David

    2016-12-19

    This paper presents a capacitive sensor for monitoring parallel microfluidic droplet generation. The great electric permittivity difference between common droplet microfluidic fluids such as air, oil and water (ϵoil ≈ 2–3 and ϵwater ≈ 80.4), allows for accurate detection of water in oil concentration changes. Capacitance variations as large as 10 pF between a channel filled with water or dodecane, are used to continuously monitor the output of a parallelization system producing 150 µl/min of water in dodecane emulsions. We also discuss a low cost fabrication process to manufacture these capacitive sensors, which can be integrated to different substrates.

  9. Continuous Right Radial Arterial Pressure Monitoring as a Guide to Dissection of a Thoracic Inlet Neurofibroma.

    Science.gov (United States)

    Ravindra, Madhavi Nishtala

    2015-09-01

    Excision of tumors in the thoracic inlet entail a risk of injury to subclavian vessels due to their close proximity. A right radial artery line can sensitively and continuously monitor the occurrence of right subclavian artery compression and warn the surgeon of its proximity and prevent injury. We describe a case of thoracic inlet tumor in a 12-year-old child, wherein the use of radial artery pressure monitoring guided the surgeon to separate the subclavian artery from the tumor to which it was adherent. © The Author(s) 2015.

  10. Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhiwei, E-mail: jiayege@hotmail.com [College of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha (China); Yan, Guozheng; Zhu, Bingquan [820 Institute, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China)

    2015-04-15

    An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.

  11. Wi-Fi Based Vital Signs Monitoring and Tracking System for Medical Parameters

    Directory of Open Access Journals (Sweden)

    Mr. Deshmukh Rohit Sunil

    2013-05-01

    Full Text Available Patients at a disaster scene can greatly benefit from technologies that continuously monitor their vital status and track their locations until they are admitted to the hospital. We have designed and developed a real-time patient monitoring system that integrates vital sign sensors, location sensor, ad-hoc networking, electronics patients status. This system shall facilitate communication between providers at a disaster scene, medical professionals at a local hospital, and specialists available for consultation from distant facilities

  12. Continuous measurements of aerosol physical parameters at the Mt. Cimone GAW Station (2165 m asl, Italy).

    Science.gov (United States)

    Marinoni, A; Cristofanelli, P; Calzolari, F; Roccato, F; Bonafè, U; Bonasoni, P

    2008-03-01

    Particle size distribution in the range 0.3cycle with the highest values in spring-summer and the lowest value in autumn-winter. Except in winter, N 0.3-1 showed a clear diurnal variation with high values during day-time. N 1-20 showed a less marked diurnal variation (but with higher variability), suggesting the influence of non-continuous sources of coarse particle (i.e. Saharan dust events). Since July 2005, continuous measurement of black carbon (BC) concentrations was also available at the measurement site. On average low BC concentrations were recorded (average value: 0.28 microg m(-3)) even if a few events of high concentrations were recorded both in warm and cold season. Apart from wet scavenging processes which strongly affected aerosol concentrations, combined analysis of N 0.3-1, BC, meteorological parameters and air mass back-trajectories, suggests that the transport of polluted air masses from the lower troposphere (by local, regional or long-range transport) represents an important mechanism favouring N 0.3-1 and BC increases at Mt. Cimone. In particular, a trajectory statistical analysis for the period July 2005-July 2006 allowed the identification of the main source regions of BC and N 0.3-1 for Mt. Cimone: north Italy, west Europe and east Europe.

  13. Patient satisfaction and barriers to initiating real-time continuous glucose monitoring in early pregnancy in women with diabetes

    DEFF Research Database (Denmark)

    Secher, A L; Madsen, A B; Nielsen, Lene Ringholm;

    2012-01-01

    for 6 days at median 9 (range 6-14) gestational weeks and were asked to answer a semi-structured questionnaire on patient satisfaction. Results: Median HbA(1c) was 49 (range 34-86) mmol/mol) [6.6 (5.3-10.0) %] and duration of diabetes was 12 (0.5-37) years. Continuous glucose monitoring was used for 6......Aim: To evaluate self-reported satisfaction and barriers to initiating real-time continuous glucose monitoring in early pregnancy among women with pregestational diabetes. Methods: Fifty-four women with Type 1 diabetes and 14 women with Type 2 diabetes were offered continuous glucose monitoring...... monitoring during daytime and twelve (18%) during sleep. Many women reported improved diabetes understanding (52%) and would recommend continuous glucose monitoring to others (83%). Twenty-four patients (36%) had continuous glucose monitoring removed earlier than planned (before the intended 6 days...

  14. Assessment of the accuracy of real-time continuous glucose monitoring system and its correlated factors

    Institute of Scientific and Technical Information of China (English)

    洛佩

    2014-01-01

    Objective To assess the factors that influence the accuracy of real-time continuous glucose monitoring system(RT-CGM).Methods A total of 79 diabetic patients wore RT-CGM for three days continuously while calibrating by interphalangeal glucose values 4-8 times a day.We counted matching rate of interphalangeal glucose values and RT-CGM probe value,and analyzed correlation of the matching rate with MAGE,SDBG,MBG,AUC10,AUC3.9,and NGE by Pearson correlation analysis and multiple linear

  15. MEMS acceleration sensor with remote optical readout for continuous power generator monitoring

    Directory of Open Access Journals (Sweden)

    Tormen Maurizio

    2015-01-01

    Full Text Available Miniaturized accelerometers with remote optical readout are required devices for the continuous monitoring of vibrations inside power generators. In turbo and hydro generators, end-winding vibrations are present during operation causing in the long term undesirable out-of-service repairs. Continuous monitoring of these vibrations is therefore mandatory. The high electromagnetic fields in the generators impose the use of devices immune to electromagnetic interferences. In this paper a MEMS based accelerometer with remote optical readout is presented. Advantages of the proposed device are the use of a differential optical signal to reject the common mode signal and noise, the reduced number of steps for the MEMS chip fabrication and for the system assembly, and the reduced package volume.

  16. A device for continuous monitoring of true central fixation based on foveal birefringence.

    Science.gov (United States)

    Gramatikov, Boris; Irsch, Kristina; Müllenbroich, Marie; Frindt, Nicole; Qu, Yinhong; Gutmark, Ron; Wu, Yi-Kai; Guyton, David

    2013-09-01

    A device for continuous monitoring of central fixation utilizes birefringence, the property of the Henle fibers surrounding the human fovea, to change the polarization state of light. A circular scan of retinal birefringence, where the scanning circle encompasses the fovea, allows identification of true central fixation-an assessment much needed in various applications in ophthalmology, psychology, and psychiatry. The device allows continuous monitoring for central fixation over an extended period of time in the presence of fixation targets and distracting stimuli, which may be helpful in detecting attention deficit hyperactivity disorder, autism spectrum disorders, and other disorders characterized by changes in the subject's ability to maintain fixation. A proof-of-concept has been obtained in a small study of ADHD patients and normal control subjects.

  17. Development of an automated system for continuous monitoring of powered roof support in longwall panel

    Institute of Scientific and Technical Information of China (English)

    ATUL Kumar; DHEERAJ Kumar; SINGH U.K.; GUPTA P.S.

    2010-01-01

    Described the development of an Intrinsically Safe System for continuous monitoring of load and convergence of powered roof supports installed at longwall faces.The system developed for monitoring of behavior of a powered support in a mechanized longwall sublevel caving face. The logging system can be programmed for logging the data from the sensors at different logging intervals ranging from 16 h to 1 ms for logging variation in hydraulic pressures in legs and convergence of the support during progressive face advance. For recording dynamic loads, the data logger can be programmed to start fast logging, say at 10 ms intervals, when the pressure in a leg reaches a pre-specified threshold value, and continue fast logging until the pressure drops below this threshold value. This fast logging automatically stops when the pressure drops below this threshold value.

  18. Optical measurement system applied to continuous displacement monitoring of long-span suspension bridges

    Science.gov (United States)

    Lages Martins, L.; Rebordão, J. M.; Ribeiro, A. S.

    2013-04-01

    This paper provides a general description of main issues related to the design of an optical measurement system applied to continuous displacement monitoring of long-span suspension bridges. The proposed system's architecture is presented and its main components - camera and active targets - are described in terms of geometrical and radiometric characteristics required for long distance measurement of the tridimensional displacement of the stiffness girder in the middle section of the bridge's central span. The intrinsic and extrinsic camera parameterization processes, which support the adopted measurement approach, are explained in a specific section. Since the designed measurement system is intended to perform continuous displacement monitoring in long distance observation framework, particular attention is given to environmental effects, namely, refraction, turbulence and sensor saturation phenomena, which can influence the displacement measurement accuracy. Finally, a measurement uncertainty method is discussed in order to provide a suitable solution for the determination of the accuracy related to the proposed measurement approach.

  19. Comparative study of gas-analyzing systems designed for continuous monitoring of TPP emissions

    Science.gov (United States)

    Kondrat'eva, O. E.; Roslyakov, P. V.

    2017-06-01

    Determining the composition of combustion products is important in terms of both control of emissions into the atmosphere from thermal power plants and optimization of fuel combustion processes in electric power plants. For this purpose, the concentration of oxygen, carbon monoxide, nitrogen, and sulfur oxides in flue gases is monitored; in case of solid fuel combustion, fly ash concentration is monitored as well. According to the new nature conservation law in Russia, all large TPPs shall be equipped with continuous emission monitoring and measurement systems (CEMMS) into the atmosphere. In order to ensure the continuous monitoring of pollutant emissions, direct round-the-clock measurements are conducted with the use of either domestically produced or imported gas analyzers and analysis systems, the operation of which is based on various physicochemical methods and which can be generally used when introducing CEMMS. Depending on the type and purposes of measurement, various kinds of instruments having different features may be used. This article represents a comparative study of gas-analysis systems for measuring the content of polluting substances in exhaust gases based on various physical and physicochemical analysis methods. It lists basic characteristics of the methods commonly applied in the area of gas analysis. It is proven that, considering the necessity of the long-term, continuous operation of gas analyzers for monitoring and measurement of pollutant emissions into the atmosphere, as well as the requirements for reliability and independence from aggressive components and temperature of the gas flow, it is preferable to use optical gas analyzers for the aforementioned purposes. In order to reduce the costs of equipment comprising a CEMMS at a TPP and optimize the combustion processes, electrochemical and thermomagnetic gas analyzers may also be used.

  20. 脉搏指示连续心排血量技术对压力与容量控制模式机械通气容量参数的影响%Influence of pulse indicator continuous cardiac output in monitoring on the volume parameters of different tidal volume under pressure control ventilation mode and volume-controlled ventilation mode in sheep

    Institute of Scientific and Technical Information of China (English)

    李军; 高心晶; 高艳颖; 卫俊涛; 秦英智

    2010-01-01

    Objective To compare the influence of pulse indicator continuous cardiac output(PiCCO)in monitoring tidal volume(V_T)under pressure control ventilation mode and volume-controlled ventilation mode in sheep.Methods After anesthesia and tracheotomy,5 sheep,which were apneic and receiving mechanical ventilation.Twenty minutes later,central venous pressure(CVP)and cardiac function were monitored with different selected V_T levels of 6,10,15,20 ml/kg under bi-level positive airway pressure (BiPAP)mode by changing the pressure of inspiration,or under the synchronized intermittent mandatory ventilation(SIMV)mode with the same ventilation conditions.Results In both modes,the increase in V_T led to an decrease of cardiac index(CI)and intrathoracic blood volume index(ITBVI),reaching a statistically significant difference at 15 ml/kg[SIMV mode:CI(3.94±1.03)L·min~(-1)·m~(-2),ITBVI (707±105)ml/m2;BiPAP mode:CI(4.11±1.11)L·min-1±m-2,ITBVI(715±122)ml/m2]and 20 ml/kg[SIMV mode:CI(3.87±1.04)L·min~(-1)·m~(-2),ITBVI(705±116)ml/m2;BiPAP mode:CI (3.64±0.96)L·min~(-1)·m~(-2),ITBVI(694±114)ml/m2]compared with 6 ml/kg[SIMV mode:CI (4.96±1.58)L·min~(-1)·m~(-2),ITBVI(811±169)ml/m2;BiPAP mode:CI(5.67±1.96)L·min~(-1)·m~(-2),ITBVI(8234-182)ml/m~2,all P<0.05];an increase in systemic vascular resistance index(SVRI)and mean airway pressure(Pmean)at 15 ml/kg[SIMV mode:SVRI(237.64±6.2)kPa·s~(-1)·L~(-1),Pmean(14.0±3.2)cm H2O(1 cm H2O=0.098 kPa);BiPAP mode:SVRI(230.8±32.9)kPa·s~(-1)·L~(-1),Pmean(13.0±2.2)cm H_2O]and 20 ml/kg[SIMV mode:SVRI(253.1±76.7)kPa·s~(-1)·L~(-1),Pmean(18.2±4.8)cm H_2O;BiPAP mode:SVRI(246.7±48.8)kPa·s~(-1)·L~(-1),Pmean(16.8±3.3)cm H_2O]compared with 6 ml/kg[SIMV mode:SVRI(184.8±47.5)kPa·s~(-1)·L~(-1);Pmean(8.8±1.6)cm H_2O;BiPAP mode:SVRI(184.5±51.5)kPa·s~(-1)·L~(-1),Pmean(8.6±0.5)cm H_2O,all P<0.05];but there was no significant effects on CVP,heart rate(HR),mean blood pressure(MBP).There was no significant difference of CI

  1. RFID Technology for Continuous Monitoring of Physiological Signals in Small Animals.

    Science.gov (United States)

    Volk, Tobias; Gorbey, Stefan; Bhattacharyya, Mayukh; Gruenwald, Waldemar; Lemmer, Björn; Reindl, Leonhard M; Stieglitz, Thomas; Jansen, Dirk

    2015-02-01

    Telemetry systems enable researchers to continuously monitor physiological signals in unrestrained, freely moving small rodents. Drawbacks of common systems are limited operation time, the need to house the animals separately, and the necessity of a stable communication link. Furthermore, the costs of the typically proprietary telemetry systems reduce the acceptance. The aim of this paper is to introduce a low-cost telemetry system based on common radio frequency identification technology optimized for battery-independent operational time, good reusability, and flexibility. The presented implant is equipped with sensors to measure electrocardiogram, arterial blood pressure, and body temperature. The biological signals are transmitted as digital data streams. The device is able of monitoring several freely moving animals housed in groups with a single reader station. The modular concept of the system significantly reduces the costs to monitor multiple physiological functions and refining procedures in preclinical research.

  2. A Feasibility Study for Life Signs Monitoring via a Continuous-Wave Radar

    Directory of Open Access Journals (Sweden)

    Francesco Soldovieri

    2012-01-01

    Full Text Available We present a feasibility study for life signs detection using a continuous-wave radar working in the band around 4 GHz. The data-processing is carried out by using two different data processing approaches, which are compared about the possibility to characterize the frequency behaviour of the breathing and heartbeat activity. The two approaches are used with the main aim to show the possibility of monitoring the vital signs activity in an accurate and reliable way.

  3. Acoustic monitoring on a humpback whale (Megaptera novaeangliae) feeding ground shows continual singing into late Spring.

    OpenAIRE

    Clark, Christopher W.; Clapham, Phillip J.

    2004-01-01

    Singing by males is a major feature of the mating system of humpback whales, Megaptera novaeangliae (Borowski). Although a few songs have been opportunistically recorded on the whales' high-latitude feeding grounds, singing in these regions was thought to be only sporadic. We report results from the first continuous acoustic monitoring of a humpback whale feeding ground (off Cape Cod, MA, USA) in spring. Using autonomous sea-floor recording systems, we found singing on a daily basis over the ...

  4. Continuous monitoring of blood pressure in children and adolescents,a review of the literature.

    Science.gov (United States)

    Mercado, Arlene B

    2008-08-01

    Continuous or ambulatory blood pressure monitoring (CBPM or ABPM) is becoming a useful tool in the early detection of hypertension in children and adolescents. With increased obesity in pediatrics, chronic diseases such as hypertension, diabetes, dyslipidemia and metabolic syndrome which was more commonly seen in adults in the early years, can now be seen in this population. This review provides the clinical reports of the use of CBPM for diagnosis and management of hypertension in the pediatric population.

  5. Continuation of long-term global SO2 pollution monitoring from OMI to OMPS

    OpenAIRE

    Zhang, Yan; Li, Can; Nickolay A. Krotkov; Joiner, Joanna

    2016-01-01

    Over the past 20 years, advances in satellite remote sensing of pollution-relevant species have made space-borne observations an increasingly important part of atmospheric chemistry research and air quality management. This progress has been facilitated by advanced UV-Vis spectrometers, such as the Ozone Monitoring Instrument (OMI) on board the NASA EOS Aura satellite, and continues with new instruments, such as the Ozone Mapping and Profiler Suite (OMPS) on board the NASA-NOAA Suomi National...

  6. Continuous monitoring of membrane protein micro-domain association during cell signaling

    CERN Document Server

    Huang, Heng

    2011-01-01

    Central to understanding membrane bound cell signaling is to quantify how the membrane ultra-structure consisting of transient spatial domains modulates signaling and how the signaling influences this ultra-structure. Yet, measuring the association of membrane proteins with domains in living, intact cells poses considerable challenges. Here, we describe a non-destructive method to quantify protein-lipid domain and protein cytoskeleton interactions in single, intact cells enabling continuous monitoring of the protein domains interaction over time during signaling.

  7. Exercise Strategies to Optimize Glycemic Control in Type 2 Diabetes: A Continuing Glucose Monitoring Perspective

    OpenAIRE

    van Dijk, Jan-Willem; van Loon, Luc J. C.

    2015-01-01

    IN BRIEF The introduction of continuous glucose monitoring (CGM) several years ago enabled researchers to investigate the impact of exercise strategies on 24-hour glycemic control. Such unique information on the glucoregulatory properties of exercise will ultimately lead to more effective exercise programs to prevent and treat type 2 diabetes. This article reviews the role of exercise and physical activity in the treatment of type 2 diabetes, complemented by recent data obtained by CGM.

  8. Distributed Dynamic State Estimator, Generator Parameter Estimation and Stability Monitoring Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Meliopoulos, Sakis [Georgia Inst. of Technology, Atlanta, GA (United States); Cokkinides, George [Georgia Inst. of Technology, Atlanta, GA (United States); Fardanesh, Bruce [New York Power Authority, NY (United States); Hedrington, Clinton [U.S. Virgin Islands Water and Power Authority (WAPA), St. Croix (U.S. Virgin Islands)

    2013-12-31

    This is the final report for this project that was performed in the period: October1, 2009 to June 30, 2013. In this project, a fully distributed high-fidelity dynamic state estimator (DSE) that continuously tracks the real time dynamic model of a wide area system with update rates better than 60 times per second is achieved. The proposed technology is based on GPS-synchronized measurements but also utilizes data from all available Intelligent Electronic Devices in the system (numerical relays, digital fault recorders, digital meters, etc.). The distributed state estimator provides the real time model of the system not only the voltage phasors. The proposed system provides the infrastructure for a variety of applications and two very important applications (a) a high fidelity generating unit parameters estimation and (b) an energy function based transient stability monitoring of a wide area electric power system with predictive capability. Also the dynamic distributed state estimation results are stored (the storage scheme includes data and coincidental model) enabling an automatic reconstruction and “play back” of a system wide disturbance. This approach enables complete play back capability with fidelity equal to that of real time with the advantage of “playing back” at a user selected speed. The proposed technologies were developed and tested in the lab during the first 18 months of the project and then demonstrated on two actual systems, the USVI Water and Power Administration system and the New York Power Authority’s Blenheim-Gilboa pumped hydro plant in the last 18 months of the project. The four main thrusts of this project, mentioned above, are extremely important to the industry. The DSE with the achieved update rates (more than 60 times per second) provides a superior solution to the “grid visibility” question. The generator parameter identification method fills an important and practical need of the industry. The “energy function” based

  9. [Current status of continuous subcutaneous insulin infusion and continuous glucose monitoring systems in the Community of Madrid].

    Science.gov (United States)

    Arranz Martín, Alfonso; Calle Pascual, Alfonso; Del Cañizo Gómez, Francisco Javier; González Albarrán, Olga; Lisbona Gil, Arturo; Botella Serrano, Marta; Pallardo Sánchez, Luis Felipe

    2015-04-01

    To analyze the available information about continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring (CGM) systems in the public health care system of the Community of Madrid. A survey consisting of 31 items was sent to the 28 endocrinology department of the Madrid public hospitals. Items focused on CSII and CGM and included patients' registrations, as well as data regarding healthcare, administrative, and logistic aspects. Responses from a total of 20 hospitals where these procedures are used were received from March 2013 to May 2014. Data about pediatric patients were obtained from adult endocrinology departments, except for two hospitals which directly reported the information. A total of 1256 CSII pumps were recorded in the Madrid region, of which 1089 were used by adults, and the remaining 167 by pediatric patients. During 2013, 151 new CSII systems were implanted (12% of the total), while 14 pumps were withdrawn. Availability of human resources (medical assistance) and the number of staff practitioners experienced in management of these systems widely varied between hospitals. Eighty-five percent of hospitals used retrospective CGM systems, and 40% routinely placed them before starting an insulin pump. Thirteen hospitals (65%) used long-term, real-time CGM systems in selected cases (a total of 67 patients). Use of these technologies in diabetes is unequal between public health care hospitals in Madrid, and is still significantly lower as compared to other countries with similar incomes. However, there appears to be a trend to an increase in their use. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  10. Automated, Multiplexed Electrical Impedance Spectroscopy Platform for Continuous Monitoring of Microtissue Spheroids.

    Science.gov (United States)

    Bürgel, Sebastian C; Diener, Laurin; Frey, Olivier; Kim, Jin-Young; Hierlemann, Andreas

    2016-11-15

    Microtissue spheroids in microfluidic devices are increasingly used to establish novel in vitro organ models of the human body. As the spheroids are comparably sizable, it is difficult to monitor larger numbers of them by optical means. Therefore, electrical impedance spectroscopy (EIS) emerges as a viable alternative to probing spheroid properties. Current spheroid EIS systems are, however, not suitable for investigating multiple spheroids in parallel over extended time in an automated fashion. Here we address this issue by presenting an automated, multiplexed EIS (AMEIS) platform for impedance analysis in a microfluidic setting. The system was used to continuously monitor the effect of the anticancer drug fluorouracil (5-FU) on HCT116 cancer spheroids. Simultaneous EIS monitoring of up to 15 spheroids was performed in parallel over 4 days at a temporal resolution of 2 min without any need for pumps. The measurements were continuous in nature, and the setup was kept in a standard incubator under controlled conditions during the measurements. A baseline normalization method to improve robustness and to reduce the influence of slow changes in the medium conductivity on the spheroid EIS readings has been developed and validated by experiments and means of a finite-element model. The same method and platform was then used for online monitoring of cardiac spheroids. The beating frequency of each cardiac spheroid could be read out in a completely automated fashion. The developed system constitutes a promising method for simultaneously evaluating drug impact and/or toxic effects on multiple microtissue spheroids.

  11. Wireless non-invasive continuous respiratory monitoring with FMCW radar: a clinical validation study.

    Science.gov (United States)

    van Loon, K; Breteler, M J M; van Wolfwinkel, L; Rheineck Leyssius, A T; Kossen, S; Kalkman, C J; van Zaane, B; Peelen, L M

    2016-12-01

    Altered respiratory rate is one of the first symptoms of medical conditions that require timely intervention, e.g., sepsis or opioid-induced respiratory depression. To facilitate continuous respiratory rate monitoring on general hospital wards a contactless, non-invasive, prototype monitor was developed using frequency modulated continuous wave radar. We aimed to study whether radar can reliably measure respiratory rate in postoperative patients. In a diagnostic cross-sectional study patients were monitored with the radar and the reference monitor (pneumotachograph during mechanical ventilation and capnography during spontaneous breathing). Eight patients were included; yielding 796 min of observation time during mechanical ventilation and 521 min during spontaneous breathing. After elimination of movement artifacts the bias and 95 % limits of agreement for mechanical ventilation and spontaneous breathing were -0.12 (-1.76 to 1.51) and -0.59 (-5.82 to 4.63) breaths per minute respectively. The radar was able to accurately measure respiratory rate in mechanically ventilated patients, but the accuracy decreased during spontaneous breathing.

  12. Health monitoring of a continuous rigid frame bridge based on PZT impedance and strain measurements

    Science.gov (United States)

    Zhang, Junbing; Zhu, Hongping; Wang, Dansheng; He, Bo; Zhou, Huaqiang

    2009-07-01

    Critical civil infrastructures such as bridges, dams, and pipelines present a major investment and their safety and security affect the life of citizens and national economic development. So it is very important for engineers and researchers to monitor their integrity while in operation and throughout. In recent years, the piezoelectric-ceramic (PZT) patches, which serve both as impedance sensors and actuators, have been increasingly used for structural health monitoring. This paper presents an impedance-based method, which utilizes the electro-mechanical coupling property of PZT sensors. There are a lot of advantages of this method, such as not based on any physical models, sensitive to tiny damage for its high frequency characteristics. An engineering application of this method for health monitoring of a continuous rigid frame bridge is implemented in this study. Some PZT active sensors are embedded into critical sections of the continuous rigid-frame box beam. The electrical admittances of these distributed PZT sensors are measured when the bridge is constructing or suffering from operational loads. For comparison, strain gauges are arranged in adjacent regions of these PZT sensors to obtain the strains of concrete around them at the same time. Based on the admittance sigatures obtained form PZT sensors and the strain measurements of concrete around them, the health status of the bridge is monitored and evaluated successfully.

  13. Continuous monitoring of arthritis in animal models using optical imaging modalities

    Science.gov (United States)

    Son, Taeyoon; Yoon, Hyung-Ju; Lee, Saseong; Jang, Won Seuk; Jung, Byungjo; Kim, Wan-Uk

    2014-10-01

    Given the several difficulties associated with histology, including difficulty in continuous monitoring, this study aimed to investigate the feasibility of optical imaging modalities-cross-polarization color (CPC) imaging, erythema index (EI) imaging, and laser speckle contrast (LSC) imaging-for continuous evaluation and monitoring of arthritis in animal models. C57BL/6 mice, used for the evaluation of arthritis, were divided into three groups: arthritic mice group (AMG), positive control mice group (PCMG), and negative control mice group (NCMG). Complete Freund's adjuvant, mineral oil, and saline were injected into the footpad for AMG, PCMG, and NCMG, respectively. LSC and CPC images were acquired from 0 through 144 h after injection for all groups. EI images were calculated from CPC images. Variations in feet area, EI, and speckle index for each mice group over time were calculated for quantitative evaluation of arthritis. Histological examinations were performed, and the results were found to be consistent with those from optical imaging analysis. Thus, optical imaging modalities may be successfully applied for continuous evaluation and monitoring of arthritis in animal models.

  14. THE TASK OF CONTINUING AIRWORTHINESS ON THE BASIS OF MONITORING RESOURCE STATUS

    Directory of Open Access Journals (Sweden)

    Yuriy M. Chinyuchin

    2017-01-01

    Full Text Available This article is devoted to basic statements according to scientific researches carried out in the area of airworthiness maintenance and aimed at creation of monitoring system of the aircraft equipment resource condition for the purpose of its resource and service life parameters control.The term monitoring is used here as consecutive process of obtaining, processing and analyzing the information on resources and aircraft equipment service life (planes, helicopters, aircraft engines and their accessories with the further use of this information for the problems solution of its own air fleet structure management, its updating and forecasting indica- tors of its operation processes efficiency.The most important and complex components of monitoring system and aircraft equipment resource condition, in particular are noted: the personified approach to the definition of aircraft equipment rational resources and service life; models of forecasting and aircraft resources processing management; decision-making models on increase of long life air- craft parameters taking into account maintenance cost; justification of expediency of aeronautical products retrofit by way of increasing their resource characteristics; definition methods of resource products necessary quantity by using of statisti- cal model; assessment methods of aviation components authenticity value; models of technical and economic efficiency of works on increase in individual resources of removable parts.Certain components of monitoring system are considered in more detail with the references indication.

  15. Ten years of continuous monitoring of soil CO2 flux: results and implications from the first geochemical monitoring network on Mount Etna.

    Science.gov (United States)

    Liuzzo, Marco; Gurrieri, Sergio; Giuffrida, Giovanni; Gaetano, Giudice; Cappuzzo, Santino

    2013-04-01

    Throughout the Mediterranean area, Mt. Etna is well known for its frequent eruptions and considerable lava flows, being, among all of the basaltic volcanoes, one of the most active in the world. The frequent activity of the last two decades has induced the scientific community and the Civil Defence to pay more attention to the surveillance of the volcano and, in view of this, a diverse range of monitoring systems have been developed, making Mt. Etna one of the most intensively studied volcanoes in the world. The measurement of soil CO2 flux for the purpose of identifying a possible correlation between CO2 flux variations and volcanic activity has been carried out for a long time on several active volcanoes around the world. Whilst almost all of these measurements have been made using direct sampling methods in the field, various kinds of automatic devices have more recently been developed to record real-time data, allowing a continuous remote monitoring of volcanic areas. On Mt. Etna the first network of continuous monitoring of geochemical parameters was developed in 2002 by the Istituto Nazionale di Geofisica e Vulcanologia (INGV) of Palermo to monitor CO2 flux from the soil (EtnaGAS network) and was installed at various sites (18 in total) on the flanks of Mt. Etna. The very large quantity of soil CO2 flux data recorded by the network, during which several interesting eruptive phenomena took place, has provided the possibility to make an extensive statistical analysis, the outcome of which strongly suggests that anomalous measurements of CO2 flux was attributable to a volcanic origin and, in almost all cases, preceded the onset of volcanic activity. Here we present an interpretative model of the expected behaviour of CO2 flux from the soil (in terms of cycles of increase-decrease) during and between eruptions, and the actual data-series recorded by EtnaGAS which we found corresponded well with our model. A comparative multidisciplinary approach, incorporating

  16. [Intraoperative monitoring in artificial respiration of premature and newborn infants. I. Monitoring of respiratory parameters and alveolar ventilation].

    Science.gov (United States)

    Lenz, G; Heipertz, W; Leidig, E; Madee, S

    1986-06-01

    Monitoring of ventilation serves to ensure adequate alveolar ventilation and arterial oxygenation, and to avoid pulmonary damage due to mechanical ventilation. Basic clinical monitoring, i.e., inspection, auscultation (including precordial or oesophageal stethoscope) and monitoring of heart rate and blood pressure, is mandatory. Mechanical ventilation is monitored by ventilation pressures (peak pressure, plateau pressure and endexpiratory pressure), ventilation volumes (measured at the in/expiratory valve of the respirator and by hot-wire anemometry at the tube connector), ventilation rate, and inspiratory oxygen concentration (FiO2). Alveolar ventilation should be continuously and indirectly recorded by capnometry (pECO2) and by measurement of transcutaneous pCO2 (tcpCO2), whereas oxygenation is determined via measurement of transcutaneous pO2 (tcpO2). Invasive monitoring of gas exchange is essential in prolonged or intrathoracic interventions as well as in neonates with cardiopulmonary problems. paCO2 may be estimated by capillary or venous blood gas analysis; arterial blood gas analysis is required for exact determination of paCO2 as well as arteriocutaneous pCO2 (atcDCO2) and arterio-end-expiratory (aEDCO2) gradients.

  17. An Integrated Environment Monitoring System for Underground Coal Mines—Wireless Sensor Network Subsystem with Multi-Parameter Monitoring

    Directory of Open Access Journals (Sweden)

    Yu Zhang

    2014-07-01

    Full Text Available Environment monitoring is important for the safety of underground coal mine production, and it is also an important application of Wireless Sensor Networks (WSNs. We put forward an integrated environment monitoring system for underground coal mine, which uses the existing Cable Monitoring System (CMS as the main body and the WSN with multi-parameter monitoring as the supplementary technique. As CMS techniques are mature, this paper mainly focuses on the WSN and the interconnection between the WSN and the CMS. In order to implement the WSN for underground coal mines, two work modes are designed: periodic inspection and interrupt service; the relevant supporting technologies, such as routing mechanism, collision avoidance, data aggregation, interconnection with the CMS, etc., are proposed and analyzed. As WSN nodes are limited in energy supply, calculation and processing power, an integrated network management scheme is designed in four aspects, i.e., topology management, location management, energy management and fault management. Experiments were carried out both in a laboratory and in a real underground coal mine. The test results indicate that the proposed integrated environment monitoring system for underground coal mines is feasible and all designs performed well as expected.

  18. Analyzing the performance of fluorescence parameters in the monitoring of leaf nitrogen content of paddy rice

    Science.gov (United States)

    Yang, Jian; Gong, Wei; Shi, Shuo; Du, Lin; Sun, Jia; Song, Shalei; Chen, Biwu; Zhang, Zhenbing

    2016-06-01

    Leaf nitrogen content (LNC) is a significant factor which can be utilized to monitor the status of paddy rice and it requires a reliable approach for fast and precise quantification. This investigation aims to quantitatively analyze the correlation between fluorescence parameters and LNC based on laser-induced fluorescence (LIF) technology. The fluorescence parameters exhibited a consistent positive linear correlation with LNC in different growing years (2014 and 2015) and different rice cultivars. The R2 of the models varied from 0.6978 to 0.9045. Support vector machine (SVM) was then utilized to verify the feasibility of the fluorescence parameters for monitoring LNC. Comparison of the fluorescence parameters indicated that F740 is the most sensitive (the R2 of linear regression analysis of the between predicted and measured values changed from 0.8475 to 0.9226, and REs ranged from 3.52% to 4.83%) to the changes in LNC among all fluorescence parameters. Experimental results demonstrated that fluorescence parameters based on LIF technology combined with SVM is a potential method for realizing real-time, non-destructive monitoring of paddy rice LNC, which can provide guidance for the decision-making of farmers in their N fertilization strategies.

  19. Developing a monitoring method facilitating continual improvements in the sorting of waste at recycling centres.

    Science.gov (United States)

    Krook, Joakim; Eklund, Mats

    2010-01-01

    Beneficial use of waste relies on efficient systems for collection and separation. In Sweden, a bring system involving recycling centres for collection of bulky, electr(on)ic and hazardous waste has been introduced. A significant share of this waste is incorrectly sorted, causing downstream environmental implications. At present, however, there is a lack of affordable and accurate monitoring methods for providing the recycling centres with the necessary facts for improving the sorting of waste. The aim of this study was therefore to evaluate the usability of a simplified and potentially more suitable waste monitoring method for recycling centres. This method is based on standardised observations where the occurrence of incorrect sorting is monitored by taking digital pictures of the waste which then are analysed according to certain guidelines. The results show that the developed monitoring method could offer a resource-efficient and useful tool for proactive quality work at recycling centres, involving continuous efforts in developing and evaluating measures for improved sorting of waste. More research is however needed in order to determine to what extent the obtained results from the monitoring method are reliable.

  20. An enzymatic microreactor based on chaotic micromixing for enhanced amperometric detection in a continuous glucose monitoring application

    NARCIS (Netherlands)

    Moon, B.-U.; Koster, S.; Wientjes, K.J.C.; Kwapiszewski, R.M.; Schoonen, A.J.M.; Westerink, B.H.C.; Verpoorte, E.

    2010-01-01

    The development of continuous glucose monitoring systems is a major trend in diabetes-related research. Small, easy-to-wear systems which are robust enough to function over many days without maintenance are the goal. We present a new sensing system for continuous glucose monitoring based on a micror

  1. An enzymatic microreactor based on chaotic micromixing for enhanced amperometric detection in a continuous glucose monitoring application

    NARCIS (Netherlands)

    Moon, B.-U.; Koster, S.; Wientjes, K.J.C.; Kwapiszewski, R.M.; Schoonen, A.J.M.; Westerink, B.H.C.; Verpoorte, E.

    2010-01-01

    The development of continuous glucose monitoring systems is a major trend in diabetes-related research. Small, easy-to-wear systems which are robust enough to function over many days without maintenance are the goal. We present a new sensing system for continuous glucose monitoring based on a

  2. 40 CFR Table 6 to Subpart Ppp of... - Process Vents From Continuous Unit Operations-Monitoring, Recordkeeping, and Reporting Requirements

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Process Vents From Continuous Unit Operations-Monitoring, Recordkeeping, and Reporting Requirements 6 Table 6 to Subpart PPP of Part 63... Subpart PPP of Part 63—Process Vents From Continuous Unit Operations—Monitoring, Recordkeeping, and...

  3. The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy

    DEFF Research Database (Denmark)

    Battelino, T; Conget, I; Olsen, B

    2012-01-01

    The aim of this multicentre, randomised, controlled crossover study was to determine the efficacy of adding continuous glucose monitoring (CGM) to insulin pump therapy (CSII) in type 1 diabetes.......The aim of this multicentre, randomised, controlled crossover study was to determine the efficacy of adding continuous glucose monitoring (CGM) to insulin pump therapy (CSII) in type 1 diabetes....

  4. Design of wireless multi-parameter monitoring system for oral feeding of premature infants.

    Science.gov (United States)

    Wang, Yu-Lin; Kuo, Hsing-Chien; Wang, Lin-Yu; Ko, Mei-Ju; Lin, Bor-Shyh

    2016-07-01

    Premature infants often cannot successfully and coordinately complete their oral feeding. Mature sucking, swallowing, and respiration activities are crucial indicators for the survival of newborn infants. Due to the vulnerability and unobvious muscle activities of premature infants, current clinical care givers mainly depend on the subjective behavioral observation of infants during oral feeding. There is still lack of an integrated oral feeding monitoring system to objectively and quantifiably monitor the related physiological parameters of premature infants. In this study, a wireless multi-parameter monitoring system for oral feeding of premature infants was proposed to monitor the sucking-swallowing-respiratory activities and the heart rate variability to provide quantitative indices of oral feeding. Here, a novel sucking pressure sensing module was also developed to monitor the premature infant's sucking pressure under oral feeding to avoid the immersion influence of milk. The experimental results showed that the proposed system detected the related physiological parameters of premature infants during oral feeding effectively and may provide an objective clinical evaluation tool for oral feeding ability and safety of premature infants in the future.

  5. Validity of DynaPort GaitMonitor for assessment of spatiotemporal parameters in amputee gait

    NARCIS (Netherlands)

    Houdijk, Han; Appelman, Franka M; Van Velzen, Judith M; Van der Woude, Lucas H V; Van Bennekom, Coen A M

    2008-01-01

    Accelerometry can be used to objectively assess the walking ability of people with a lower-limb prosthesis inside and outside the laboratory setting. In this study, the validity of the DynaPort GaitMonitor software (McRoberts, The Hague, the Netherlands) for assessing spatiotemporal parameters of am

  6. 40 CFR 60.3039 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Science.gov (United States)

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.3039 Section 60.3039 Protection of Environment... emission monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen....

  7. 40 CFR 60.2940 - How do I make sure my continuous emission monitoring systems are operating correctly?

    Science.gov (United States)

    2010-07-01

    ... emission monitoring systems are operating correctly? 60.2940 Section 60.2940 Protection of Environment... monitoring systems are operating correctly? (a) Conduct initial, daily, quarterly, and annual evaluations of your continuous emission monitoring systems that measure carbon monoxide and oxygen. (b) Complete...

  8. Monitoring of the electrical parameters in off-grid solar power system

    Science.gov (United States)

    Idzkowski, Adam; Leoniuk, Katarzyna; Walendziuk, Wojciech

    2016-09-01

    The aim of this work was to make a monitoring dedicated to an off-grid installation. A laboratory set, which was built for that purpose, was equipped with a PV panel, a battery, a charge controller and a load. Additionally, to monitor electrical parameters from this installation there were used: LabJack module (data acquisition card), measuring module (self-built) and a computer with a program, which allows to measure and present the off-grid installation parameters. The program was made in G language using LabVIEW software. The designed system enables analyzing the currents and voltages of PV panel, battery and load. It makes also possible to visualize them on charts and to make reports from registered data. The monitoring system was also verified by a laboratory test and in real conditions. The results of this verification are also presented.

  9. Continuous Monitoring of Nitrate and Sulfate in Aerosols with Microchip Electrophoresis

    Science.gov (United States)

    Noblitt, S. D.; Henry, C. S.; Collett, J. L.; Hering, S. V.

    2007-12-01

    Routine monitoring of aerosol composition is important since aerosols can negatively affect both the environment and health. Water-soluble inorganic ions are commonly monitored using the particle-into-liquid-sampler coupled to ion chromatography (PILS-IC). However, a less-expensive, faster, and more portable analysis system is desirable. Here, we present the coupling of microchip capillary electrophoresis (MCE) to a water-based condensation particle counter (WCPC) for rapid and continuous monitoring of chloride, nitrate, and sulfate in atmospheric aerosols. To achieve a working system, several obstacles were overcome. A working interface between the electrophoresis microchip and the WCPC sampler was developed. This interface was designed to remove insoluble particles from the analysis stream and to prevent the sampling-induced pressure gradient from altering flow in the microfluidic device. The electrophoresis separation chemistry was optimized for the small chip size, to be free from potential interfering compounds, and to operate continuously for several hours. In-field performance of the integrated system was tested with ambient aerosols. Anion analyses can be performed in less than two minutes with aerosol detection limits similar to the PILS-IC, but with greater portability and reduced cost. Coupling microfluidic devices to aerosol sampling technology proves successful for inorganic anion analysis and shows potential for faster and more sensitive measurements as well as monitoring of other water- soluble aerosol components such as organic acids, cations, and carbohydrates. The reduced cost and size relative to current technology indicate that greater deployment of monitoring stations or the advent of portable analyzers may be feasible.

  10. Continuous Glucose Monitoring in Female NOD Mice Reveals Daily Rhythms and a Negative Correlation With Body Temperature.

    Science.gov (United States)

    Korstanje, Ron; Ryan, Jennifer L; Savage, Holly S; Lyons, Bonnie L; Kane, Kevin G; Sukoff Rizzo, Stacey J

    2017-09-01

    Previous studies with continuous glucose monitoring in mice have been limited to several days or weeks, with the mouse's physical attachment to the equipment affecting behavior and measurements. In the current study, we measured blood glucose and body temperature at 10-second intervals for 12 weeks in a cohort of NOD/ShiLtJ female mice using wireless telemetry. This allowed us to obtain a high-resolution profile of the circadian rhythm of these two parameters and the onset of hyperglycemic development in real time. The most striking observations were the elevated nocturnal concentrations of glucose into the diabetic range days before elevations in diurnal glucose (when glucose concentrations are historically measured) and the strong, negative correlation between elevated blood glucose concentrations and body temperature with a steady decline of the body temperature with diabetes development. Taken together, this technological advancement provides improved resolution in the study of the disease trajectory of diabetes in mouse models, including relevant translatability to the current technologies of continuous glucose monitoring now regularly used in patients. Copyright © 2017 Endocrine Society.

  11. Continuous in-situ monitoring of dissolved gases for the characterization of the Critical Zone with a MIMS

    Science.gov (United States)

    Chatton, Eliot; Labasque, Thierry; Aquilina, Luc; de la Bernardie, Jérôme; Guihéneuf, Nicolas

    2016-04-01

    In the perspective of a temporal and spatial exploration of the Critical Zone, we developed an in situ monitoring instrument for continuous dissolved gas analysis (N2, O2, CO2, CH4, He, Ne, Ar, Kr, Xe). With a large resolution (5 orders of magnitude) and a capability of high frequency multi-tracer analysis (1 gas every 1.5 seconds), the MIMS (Membrane Inlet Mass Spectrometer) is an innovative tool allowing the investigation of a large panel of physical and biogeochemical processes. First of all, this study presents the results of groundwater tracer tests using dissolved gases in order to evaluate transport properties of a fractured media in Brittany, France (Ploemeur, ORE H+). The tracer test experiment showed that the MIMS is perfectly suitable for field work. The instrument provides precise measurements accurate enough to produce breakthrough curves during groundwater tracer tests. The results derived from 4He data gives transport parameters in good agreement with the results obtained with a fluorescent tracer. Combined with a pump and a multi-parameter probe, the MIMS is also capable to perform accurate dissolved gases well-logs allowing a real-time estimation of recharge conditions (temperature, excess air), aquifer stratification, redox conditions and groundwater residence time by 4He dating. Therefore, the MIMS is a valuable tool for in situ characterization of biogeochemical reactivity in aquatic systems, the determination of aquifer transport properties, the monitoring of groundwater recharge conditions and the characterization of aquifer-river exchanges.

  12. Cell-Based Sensor System Using L6 Cells for Broad Band Continuous Pollutant Monitoring in Aquatic Environments

    Directory of Open Access Journals (Sweden)

    Evamaria Stütz

    2012-03-01

    Full Text Available Pollution of drinking water sources represents a continuously emerging problem in global environmental protection. Novel techniques for real-time monitoring of water quality, capable of the detection of unanticipated toxic and bioactive substances, are urgently needed. In this study, the applicability of a cell-based sensor system using selected eukaryotic cell lines for the detection of aquatic pollutants is shown. Readout parameters of the cells were the acidification (metabolism, oxygen consumption (respiration and impedance (morphology of the cells. A variety of potential cytotoxic classes of substances (heavy metals, pharmaceuticals, neurotoxins, waste water was tested with monolayers of L6 cells (rat myoblasts. The cytotoxicity or cellular effects induced by inorganic ions (Ni2+ and Cu2+ can be detected with the metabolic parameters acidification and respiration down to 0.5 mg/L, whereas the detection limit for other substances like nicotine and acetaminophen are rather high, in the range of 0.1 mg/L and 100 mg/L. In a close to application model a real waste water sample shows detectable signals, indicating the existence of cytotoxic substances. The results support the paradigm change from single substance detection to the monitoring of overall toxicity.

  13. Effect of Some Operating Parameters on the Reversing Continuous Countercurrent Extraction Process

    Directory of Open Access Journals (Sweden)

    Waigoon RITTIRUT

    2009-06-01

    Full Text Available The effect of some operating parameters on the reversing continuous countercurrent extraction process including the degree of inclination of the extractor and the percent forward progression by a screw conveyor was reported. Garcinia fruit was selected as model solid while sucrose was used as soluble solid for the diffusion system. The results showed that the degree of inclination provided certain effect on concentration profile, however was still ambiguous. For experimental purpose, 5, 7 or 10° can be used. Nevertheless, the solid and liquid phase were not in contact at the end point of the extraction unit in the case of 7° and 10° where the specified draft was 1.6. Based on the highest yield, a slope of 10° should be chosen. For a percent forward progression range of 10 - 20 %, the concentration profiles for both liquid and solid phase were almost identical. However, the lowest 5 % percent forward progression led to highest concentration profile for the liquid phase.Keywords:

  14. Automatic Monitoring of Criteria Pollutants and Meteorological Parameters in Boundary Sites of Mexico City under QA/QC Standards

    Science.gov (United States)

    Martínez, A.; Ramos, R.; Sánchez, A.; Retama, A.; Fentanes, O.; Muñoz, R.; Mar, B.; Ruiz, L. G.; Torres, R.; Torres, A.; Martínez, J.

    2007-05-01

    MILAGRO, an extensive air quality monitoring campaign, was conducted in the Mexico City Metropolitan Area (MCMA) during March 2006, in order to assess the air pollutants transport and their influence at regional and global scales. In support of this campaign a number of criteria pollutants and meteorological parameters measurements were conducted in boundary sites of the MCMA in order to determine the surface conditions in these transition sites. The boundary sites were selected based on results from previous studies, information provided systematically by the Mexico City Ambient Air Monitoring Network (Sistema de Monitoreo Atmosférico, SIMAT), pollutants trends and meteorological and climatic factors that participate in the dispersion and transport under different ventilation scenarios. Seven mobile units and two fixed stations were deployed for the continuous determination of criteria pollutants and meteorological parameters. In order to warranty the pollutants concentrations measurements' quality and comparability, calibrations and verifications were implemented at the designated monitoring sites. Data had been analyzed with statistical tools and comparisons were made against nearby SIMAT stations. Several interesting conclusions were achieved.

  15. Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring.

    Science.gov (United States)

    Bandodkar, Amay J; Molinnus, Denise; Mirza, Omar; Guinovart, Tomás; Windmiller, Joshua R; Valdés-Ramírez, Gabriela; Andrade, Francisco J; Schöning, Michael J; Wang, Joseph

    2014-04-15

    This article describes the fabrication, characterization and application of an epidermal temporary-transfer tattoo-based potentiometric sensor, coupled with a miniaturized wearable wireless transceiver, for real-time monitoring of sodium in the human perspiration. Sodium excreted during perspiration is an excellent marker for electrolyte imbalance and provides valuable information regarding an individual's physical and mental wellbeing. The realization of the new skin-worn non-invasive tattoo-like sensing device has been realized by amalgamating several state-of-the-art thick film, laser printing, solid-state potentiometry, fluidics and wireless technologies. The resulting tattoo-based potentiometric sodium sensor displays a rapid near-Nernstian response with negligible carryover effects, and good resiliency against various mechanical deformations experienced by the human epidermis. On-body testing of the tattoo sensor coupled to a wireless transceiver during exercise activity demonstrated its ability to continuously monitor sweat sodium dynamics. The real-time sweat sodium concentration was transmitted wirelessly via a body-worn transceiver from the sodium tattoo sensor to a notebook while the subjects perspired on a stationary cycle. The favorable analytical performance along with the wearable nature of the wireless transceiver makes the new epidermal potentiometric sensing system attractive for continuous monitoring the sodium dynamics in human perspiration during diverse activities relevant to the healthcare, fitness, military, healthcare and skin-care domains.

  16. Modification and Continue Monitoring of Kartini Reactor Tank Liner for Long Term Safe Operation

    Energy Technology Data Exchange (ETDEWEB)

    Puradwi, I. W.; Nitiswati, S.; Tjiptono, T.; Umar, S.; Nugroho, Tri [BATAN, Yogyakarta (Indonesia)

    2013-07-01

    This paper discusses an experience on modification of bulk shielding facility (BSF) and monitoring of the Kartini reactor tank liner through in-service inspection (ISI) for long term safe operation. The objective of BSF modification is to prevent future water penetration from BSF to both the thermalizing column and space between the aluminium reactor tank liner and the concrete. Modification of BSF needs to be conducted because leakage from the BSF has entered to the area behind the aluminium tank liner and has saturated the concrete that has potential to corrode the steel reinforcement bar, and subsequently pushing the aluminium bottom tank and causing the swelling. The three swelling on the bottom tank have been continued monitoring through ISI regularly since 2001 up to now to observe and measure the three swellings profile. Result of swellings profile measurement indicated that swelling had grown slowly in size and became relatively stable. Careful analysis and assessment of the root causes of the swelling indicated that swelling do not present a threat to future safe operation of the reactor and Kartini reactor is considered to be in good condition. As an outcome of modification and continue monitoring, Kartini Reactor in Yogyakarta has been already obtained extended operation license for the third period from Nuclear Energy Regulatory Agency of Indonesia (BAPETEN) up to 2020.

  17. Emerging tools for continuous nutrient monitoring networks: Sensors advancing science and water resources protection

    Science.gov (United States)

    Pellerin, Brian; Stauffer, Beth A; Young, Dwane A; Sullivan, Daniel J.; Bricker, Suzanne B.; Walbridge, Mark R; Clyde, Gerard A; Shaw, Denice M

    2016-01-01

    Sensors and enabling technologies are becoming increasingly important tools for water quality monitoring and associated water resource management decisions. In particular, nutrient sensors are of interest because of the well-known adverse effects of nutrient enrichment on coastal hypoxia, harmful algal blooms, and impacts to human health. Accurate and timely information on nutrient concentrations and loads is integral to strategies designed to minimize risk to humans and manage the underlying drivers of water quality impairment. Using nitrate sensors as an example, we highlight the types of applications in freshwater and coastal environments that are likely to benefit from continuous, real-time nutrient data. The concurrent emergence of new tools to integrate, manage and share large data sets is critical to the successful use of nutrient sensors and has made it possible for the field of continuous nutrient monitoring to rapidly move forward. We highlight several near-term opportunities for Federal agencies, as well as the broader scientific and management community, that will help accelerate sensor development, build and leverage sites within a national network, and develop open data standards and data management protocols that are key to realizing the benefits of a large-scale, integrated monitoring network. Investing in these opportunities will provide new information to guide management and policies designed to protect and restore our nation’s water resources.

  18. Italian Contributions to the Development of Continuous Glucose Monitoring Sensors for Diabetes Management

    Directory of Open Access Journals (Sweden)

    Claudio Cobelli

    2012-10-01

    Full Text Available Monitoring glucose concentration in the blood is essential in the therapy of diabetes, a pathology which affects about 350 million people around the World (three million in Italy, causes more than four million deaths per year and consumes a significant portion of the budget of national health systems (10% in Italy. In the last 15 years, several sensors with different degree of invasiveness have been proposed to monitor glycemia in a quasi-continuous way (up to 1 sample/min rate for relatively long intervals (up to 7 consecutive days. These continuous glucose monitoring (CGM sensors have opened new scenarios to assess, off-line, the effectiveness of individual patient therapeutic plans from the retrospective analysis of glucose time-series, but have also stimulated the development of innovative on-line applications, such as hypo/hyper-glycemia alert systems and artificial pancreas closed-loop control algorithms. In this review, we illustrate some significant Italian contributions, both from industry and academia, to the growth of the CGM sensors research area. In particular, technological, algorithmic and clinical developments performed in Italy will be discussed and put in relation with the advances obtained in the field in the wider international research community.

  19. Epidemiological characterization of diabetic patients on therapy with continuous subcutaneous insulin infusion and continuous glucose monitoring in real time.

    Science.gov (United States)

    Aristizábal, Natalia; Ramírez, Alex; Hincapié-García, Jaime; Laiton, Estefany; Aristizábal, Carolina; Cuesta, Diana; Monsalve, Claudia; Hincapié, Gloria; Zapata, Eliana; Abad, Verónica; Delgado, Maria-Rocio; Torres, José-Luis; Palacio, Andrés; Botero, José

    2015-11-01

    To describe baseline characteristics of diabetic patients who were started on insulin pump and real time continuous glucose monitor (CSII-rtCGM) in a specialized center in Medellin, Colombia. All patients with diabetes with complete data who were started on CSII-rtCGM between February 2010 and May 2014 were included. This is a descriptive analysis of the sociodemographic and clinical characteristics. 141 of 174 patients attending the clinic were included. 90,1% had type 1diabetes (T1D). The average age of T1D patients at the beginning of therapy was 31,4 years (SD 14,1). 75.8% of patients had normal weight (BMI30). The median duration of T1D was 13 years (P25-P75=10.7-22.0). 14,2% of the patients were admitted at least once in the year preceding the start of CSII-rtCGM because of diabetes related complications. Mean A1c was 8.6%±1.46%. The main reasons for starting CSII-rtCGM were: poor glycemic control (50.2%); frequent hypoglycemia, nocturnal hypoglycemia, hypoglycemia related to exercise, asymptomatic hypoglycemia (30.2%); severe hypoglycemia (16.44%) and dawn phenomena (3.1%). Baseline characteristics of patients included in this study who were started on CSII-rtCGM are similar to those reported in the literature. The Clinic starts CSII-rtCGM mainly in T1D patients with poor glycemic control, frequent or severe hypoglycemia despite being on basal/bolus therapy. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  20. Fourier transformed steady-state flash evoked potentials for continuous monitoring of visual pathway function.

    Science.gov (United States)

    Bergholz, R; Lehmann, T N; Fritz, G; Rüther, K

    2008-05-01

    Monitoring of somatosensory, motor and auditory pathway function by evoked potentials is routine in surgery placing these pathways at risk. However, visual pathway function remains yet inaccessible to a reliable monitoring. For this study, a method of continuous recordings was developed and tested. Steady-state visual evoked potentials were elicited by flash stimulation at 16 Hz and analysed using discrete Fourier transform. Amplitude and phase of the fundamental response were dynamically averaged and continuously plotted in a trend graph. The method was applied on awake individuals with normal vision and on patients undergoing neurosurgery. In most individuals it was possible to continuously record significant responses. Surprisingly, characteristic time-courses of amplitude and phase were observed in several subjects. These findings were attributed mainly to flicker-adaptation. During anesthesia, amplitude and signal-to-noise ratio were markedly smaller. Signal recognition was facilitated when potentials were recorded with a subdural electrode placed directly at the occipital pole. The anesthetic agent propofol had a major impact on the recordings.

  1. Continuous glucose monitoring system and new era of early diagnosis of diabetes in high risk groups

    Directory of Open Access Journals (Sweden)

    Ashraf Soliman

    2014-01-01

    Full Text Available Continuous glucose monitoring (CGM systems are an emerging technology that allows frequent glucose measurements to monitor glucose trends in real time. Their use as a diagnostic tool is still developing and appears to be promising. Combining intermittent glucose self-monitoring (SGM and CGM combines the benefits of both. Significant improvement in the treatment modalities that may prevent the progress of prediabetes to diabetes have been achieved recently and dictates screening of high risk patients for early diagnosis and management of glycemic abnormalities. The use of CGMS in the diagnosis of early dysglycemia (prediabetes especially in high risk patients appears to be an attractive approach. In this review we searched the literature to investigate the value of using CGMS as a diagnostic tool compared to other known tools, namely oral glucose tolerance test (OGTT and measurement of glycated hemoglobin (HbA1C in high risk groups. Those categories of patients include adolescents and adults with obesity especially those with family history of type 2 diabetes mellitus, polycystic ovary syndrome (PCO, gestational diabetes, cystic fibrosis, thalassemia major, acute coronary syndrome (ACS, and after renal transplantation. It appears that the ability of the CGMS for frequently monitoring (every 5 min glucose changes during real-life settings for 3 to 5 days stretches the chance to detect more glycemic abnormalities during basal and postprandial conditions compared to other short-timed methods.

  2. Continuous EEG monitoring in the evaluation of non-convulsive seizures and status epilepticus

    Directory of Open Access Journals (Sweden)

    Murthy J

    2004-10-01

    Full Text Available Non-convulsive seizures (NCSzs and non-convulsive status epilepticus (NCSE occur in a substantial proportion of patients with acute brain injury. These acute seizure disorders are often unrecognized and under-diagnosed. Seizure semiology of NCSz is too subtle clinically to be noticed. Most often, mental status impairment is the presenting feature. Changes in the functions of the thalamo-cortical system in patients with impaired consciousness can be detected by continuous EEG (cEEG monitoring. cEEG monitoring allows detection of the changes at a reversible stage, often when there are no clinical indications of such phenomena. In addition EEG provides reasonable spatial resolution and excellent temporal resolution. This makes cEEG an excellent method for supplementing single or serial recordings in the detection of NCSzs and NCSE. Recent advances in digital EEG have made cEEG monitoring in the neurological intensive care unit (NICU technically feasible. Current evidence suggests that the common clinical denominator associated with electrographic seizures or NCSzs is mental status impairment. In NCSE, the duration of ictal activity and the time of delay to diagnosis are independent predictors of poor outcome. It will be prudent to do cEEG monitoring in any patient with impaired consciousness either in the setting of acute brain injury or with no clear explanation to detect NCSzs/NCSE. Early recognition and timely intervention is likely to be associated with good outcomes.

  3. OLAM: A wearable, non-contact sensor for continuous heart-rate and activity monitoring.

    Science.gov (United States)

    Albright, Ryan K; Goska, Benjamin J; Hagen, Tory M; Chi, Mike Y; Cauwenberghs, G; Chiang, Patrick Y

    2011-01-01

    A wearable, multi-modal sensor is presented that can non-invasively monitor a patient's activity level and heart function concurrently for more than a week. The 4 in(2) sensor incorporates both a non-contact heartrate sensor and a 5-axis inertial measurement unit (IMU), allowing simultaneous heart, respiration, and movement monitoring without requiring physical contact with the skin [1]. Hence, this Oregon State University Life and Activity Monitor (OLAM) provides the unique opportunity to combine motion data with heart-rate information, enabling assessment of actual physical activity beyond conventional movement sensors. OLAM also provides a unique platform for non-contact sensing, enabling the filtering of movement artifacts generated by the non-contact capacitive interface, using the IMU data as a movement noise channel. Intended to be used in clinical trials for weeks at a time with no physician intervention, the OLAM allows continuous non-invasive monitoring of patients, providing the opportunity for long-term observation into a patient's physical activity and subtle longitudinal changes.

  4. A Wearable Contactless Sensor Suitable for Continuous Simultaneous Monitoring of Respiration and Cardiac Activity

    Directory of Open Access Journals (Sweden)

    Gaetano D. Gargiulo

    2015-01-01

    Full Text Available A reliable system that can simultaneously and accurately monitor respiration and cardiac output would have great utility in healthcare applications. In this paper we present a novel approach to creating such a system. This noninvasive, low power, low cost, contactless sensor is suitable for continuous monitoring of respiration (tidal volume and cardiac stroke volume. Furthermore, it is capable of delivering this data in true volume (i.e., mL. The current embodiment, specifically designed for sleep monitoring applications, requires only 100 mW when powered by a 4.8 V battery pack and is based on the use of a single electroresistive band embedded in a T-shirt. Here, we describe the implementation of the device, explaining the rational and design choices for the electronic circuit and the physical garment together with the preliminary tests performed using one volunteer subject. Comparison of the device with a commercially available spirometer demonstrates that tidal volume can be monitored over extended periods with a precision of ±10%. We further demonstrate the utility of the device to measure cardiac output and respiration effort.

  5. Moisture and drug solid-state monitoring during a continuous drying process using empirical and mass balance models

    DEFF Research Database (Denmark)

    Fonteyne, Margot; Gildemyn, Delphine; Peeters, Elisabeth

    2014-01-01

    was chosen as model formulation. For the development of the NIR-based moisture determination model, 15 calibration experiments in the fluid bed dryer were performed. Six test experiments were conducted afterwards, and the product was monitored in-line with NIR and Raman spectroscopy during drying......Classically, the end point detection during fluid bed drying has been performed using indirect parameters, such as the product temperature or the humidity of the outlet drying air. This paper aims at comparing those classic methods to both in-line moisture and solid-state determination by means...... of Process Analytical Technology (PAT) tools (Raman and NIR spectroscopy) and a mass balance approach. The six-segmented fluid bed drying system being part of a fully continuous from-powder-to-tablet production line (ConsiGma™-25) was used for this study. A theophylline:lactose:PVP (30:67.5:2.5) blend...

  6. An Indirect System Identification Technique for Stable Estimation of Continuous-Time Parameters of the Vestibulo-Ocular Reflex (VOR)

    Science.gov (United States)

    Kukreja, Sunil L.; Wallin, Ragnar; Boyle, Richard D.

    2013-01-01

    The vestibulo-ocular reflex (VOR) is a well-known dual mode bifurcating system that consists of slow and fast modes associated with nystagmus and saccade, respectively. Estimation of continuous-time parameters of nystagmus and saccade models are known to be sensitive to estimation methodology, noise and sampling rate. The stable and accurate estimation of these parameters are critical for accurate disease modelling, clinical diagnosis, robotic control strategies, mission planning for space exploration and pilot safety, etc. This paper presents a novel indirect system identification method for the estimation of continuous-time parameters of VOR employing standardised least-squares with dual sampling rates in a sparse structure. This approach permits the stable and simultaneous estimation of both nystagmus and saccade data. The efficacy of this approach is demonstrated via simulation of a continuous-time model of VOR with typical parameters found in clinical studies and in the presence of output additive noise.

  7. The continuous automatic monitoring network installed in Tuscany (Italy) since late 2002, to study earthquake precursory phenomena

    Science.gov (United States)

    Pierotti, Lisa; Cioni, Roberto

    2010-05-01

    monitoring stations. This has been carried out on the basis of: i) hydrogeologic and structural studies in order to assess the underground fluid circulation regime; ii) a detailed geochemical study of all the natural manifestations present in the selected territories, such as cold and hot springs and gas emission zones; iii) logistical aspects. Therefore, a detailed hydrogeochemical study was performed in 2002. A total of 150 water points were sampled in Garfagnana/Lunigiana area (N-W Tuscany) and analysed. Based on the results of this multidisciplinary study, five water points suitable for the installation of the monitoring stations, were selected. They are: Bagni di Lucca (Bernabò spring), Gallicano (Capriz spring) and Pieve Fosciana (Prà di Lama spring) in Garfagnana, Equi Terme (main spring feeding the swimming pool of the thermal resort) and Villafranca in Lunigiana (well feeding the public swimming pool). In the Amiata area, in the preliminary campaign, 69 water points were sampled and analyzed and five sites were selected. They are Piancastagnaio, Santa Fiora, Pian dei Renai and Bagnore, which are fed by the volcanic aquifer, and Bagno Vignoni borehole, which is fed by the evaporite carbonate aquifer. The installation and start-up process of the monitoring systems in the Garfagnana-Lunigiana area begun in November 2002; in the Monte Amiata region it begun in June 2003. From the day of installation, a periodic water sampling and manual measurement of the main physical and physicochemical parameters have been carried out on a monthly basis. Such activity has the double function of performing a cross-check of the monitoring instrumentation, and carrying out additional chemical and isotopic analysis. The continuous automatic monitoring stations operate with flowing water (about 5 litres per minute) and record the following parameters: temperature (T), pH, electrical conductivity (EC), redox potential (ORP) and the content of CO2 and CH4 dissolved in water. Data are

  8. Development of continuous monitor for multiple beta-ray nuclides in liquid radioactive waste

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Uk Won; Seon, G. I.; Kong, G. N.; Chin, H.; Park, J. H.; Yuk, I. S.; Han, W. Y. [Korea Astronomy and Space Science Institute, Taejon (Korea, Republic of)

    2001-03-15

    Continuous monitor system of multiple beta-ray nuclides was designed conceptually while keeping the optimization and the automation in mind. The conincidence MCA was designed to maintain, repair and upgrade with ease. DSP was adopted to realize hardware function using software and to miniaturize the coincidence Multi Channel Analyzer (MCA). The MCA system showed 99% background rejection rate, and was applied well to gamma-ray system using {sup 60}C0. An algorithm using least square method was developed for simultaneous radioassay of multiple beta-ray nuclides. The algorithm was tested using the simulation and was applied to experimental data. The results show that the algorithm is suitable to continous monitor system of multiple beta-ray nuclides.

  9. Cardiac surgery during pregnancy: Continuous fetal monitoring using umbilical artery Doppler flow velocity indices

    Directory of Open Access Journals (Sweden)

    Manisha Mishra

    2014-01-01

    Full Text Available The fetal death rate associated with cardiac surgery with cardiopulmonary bypass (CPB is as high as 9.5-29%. We report continuous monitoring of fetal heart rate and umbilical artery flow-velocity waveforms by transvaginal ultrasonography and their analyses in relation to events of the CPB in two cases in second trimester of pregnancy undergoing mitral valve replacement. Our findings suggest that the transition of circulation from corporeal to extracorporeal is the most important event during surgery; the associated decrease in mean arterial pressure (MAP at this stage potentially has deleterious effects on the fetus, which get aggravated with the use of vasopressors. We suggest careful management of CPB at this stage, which include partial controlled CPB at initiation and gradual transition to full CPB; this strategy maintains high MAP and avoids the use of vasopressors. Maternal and fetal monitoring can timely recognize the potential problems and provide window for the required treatment.

  10. A twin-type airflow pulse ionization chamber for continuous alpha-radioactivity monitoring in atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Kada, Wataru, E-mail: kada@nf.eie.eng.osaka-u.ac.j [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan); Dwaikat, Nidal; Datemichi, Jun; Sato, Fuminobu; Murata, Isao; Kato, Yushi; Iida, Toshiyuki [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan)

    2010-10-15

    A simple and inexpensive twin-type airflow pulse ionization chamber was developed for the continuous monitoring of alpha-radioactivity in atmosphere under high humidity condition. The symmetrical structure of the twin-type ionization chamber was effective in the improvement of the ratio of signal to noise in the measurement of pulses induced by alpha-rays. Outdoor alpha-ray measurement was well performed with this ionization chamber by applying sufficiently high bias voltage to the electrodes, except for at very high humidity conditions. It was confirmed that the declination of the counting efficiency due to wetting was easily recovered by the dry-up of the inside of the chamber. Alpha-radioactivity from radon and other alpha-emitting radionuclide in atmosphere was satisfactorily monitored by the detector.

  11. Photon-monitoring attack on continuous-variable quantum key distribution with source in middle

    Science.gov (United States)

    Wang, Yijun; Huang, Peng; Guo, Ying; Huang, Dazu

    2014-12-01

    Motivated by a fact that the non-Gaussian operation may increase entanglement of an entangled system, we suggest a photon-monitoring attack strategy in the entanglement-based (EB) continuous-variable quantum key distribution (CVQKD) using the photon subtraction operations, where the entangled source originates from the center instead of one of the legal participants. It shows that an eavesdropper, Eve, can steal large information from participants after intercepting the partial beams with the photon-monitoring attach strategy. The structure of the proposed CVQKD protocol is useful in simply analyzing how quantum loss in imperfect channels can decrease the performance of the CVQKD protocol. The proposed attack strategy can be implemented under current technology, where a newly developed and versatile no-Gaussian operation can be well employed with the entangled source in middle in order to access to mass information in the EB CVQKD protocol, as well as in the prepare-and-measure (PM) CVQKD protocol.

  12. A beam monitoring and validation system for continuous line scanning in proton therapy

    Science.gov (United States)

    Klimpki, G.; Psoroulas, S.; Bula, C.; Rechsteiner, U.; Eichin, M.; Weber, D. C.; Lomax, A.; Meer, D.

    2017-08-01

    Line scanning represents a faster and potentially more flexible form of pencil beam scanning than conventional step-and-shoot irradiations. It seeks to minimize dead times in beam delivery whilst preserving the possibility of modulating the dose at any point in the target volume. Our second generation proton gantry features irradiations in line scanning mode, but it still lacks a dedicated monitoring and validation system that guarantees patient safety throughout the irradiation. We report on its design and implementation in this paper. In line scanning, we steer the proton beam continuously along straight lines while adapting the speed and/or current frequently to modulate the delivered dose. We intend to prevent delivery errors that could be clinically relevant through a two-stage system: safety level 1 monitors the beam current and position every 10 μs. We demonstrate that direct readings from ionization chambers in the gantry nozzle and Hall probes in the scanner magnets provide required information on current and position, respectively. Interlocks will be raised when measured signals exceed their predefined tolerance bands. Even in case of an erroneous delivery, safety level 1 restricts hot and cold spots of the physically delivered fraction dose to  ±36~mGy (±2% of 2~Gy biologically). In safety level 2—an additional, partly redundant validation step—we compare the integral line profile measured with a strip monitor in the nozzle to a forward-calculated prediction. The comparison is performed between two line applications to detect amplifying inaccuracies in speed and current modulation. This level can be regarded as an online quality assurance of the machine. Both safety levels use devices and functionalities already installed along the beamline. Hence, the presented monitoring and validation system preserves full compatibility of discrete and continuous delivery mode on a single gantry, with the possibility of switching between modes during the

  13. Design of Tropical Flowers Environmental Parameters Wireless Monitoring System Based on MSP430

    Directory of Open Access Journals (Sweden)

    Huang Jian-Qing

    2016-01-01

    Full Text Available Considering the importance of real-time monitoring tropical flower environment parameters, the paper designs a wireless monitoring system based on MSP430F149 for tropical flower growing parameters. The proposed system uses sensor nodes to obtain data of temperature, humidity and light intensity, sink node to collect data from sensor nodes through wireless sensor network, and monitoring center to process data downloaded from the sink node through RS232 serial port. The node hardware platform is composed of a MSP430F149 processor, AM2306 and NHZD10AI sensors used to adopt temperature, humidity and light intensity data, and an nRF905 RF chip used to receive and send data. The node software, operated in IAR Embedded Workbench, adopts C Language to do node data collection and process, wireless transmission and serial port communication. The software of monitoring center develops in VB6.0, which can provide vivid and explicit real-time monitoring platform for flower farmers.

  14. Research on multi-parameter monitoring of steel frame shaking-table test using smartphone

    Science.gov (United States)

    Han, Ruicong; Loh, Kenneth J.; Zhao, Xuefeng; Yu, Yan

    2017-04-01

    The numerical simulation promises an effective method to assess seismic damage of high-rise structure. But it's difficult to determine the input parameters and the simulation results are not completely consistent with the real condition. A more direct approach to evaluate the seismic damage is the structural health monitoring (SHM), which is one complex set of various kinds of sensors, devices and software, and always needs professionals. SHM system has achieved great development over recent years, especially on bridge structures. However it's not so popular on high-rise building due to its difficult implementation. Developing a low-cost and convenient monitoring technique will be helpful for the safety maintenance of high-rise building. Smartphones, which embedded with sensors, network transmission, data storage and processing system, are evolving towards crowdsourcing. The popularity of smartphones presents opportunities for implementation of portable SHM system on buildings. In this paper, multi-parameter monitoring of a three-story steel frame on shaking table under earthquake excitations was conducted with smartphone, and the comparison between smartphone and traditional sensors was provided. First, the monitoring applications on iOS platform, Orion-CC and D-viewer, were introduced. Then the experimental details were presented, including three-story frame model, sensors placement, viscous dampers and so on. Last, the acceleration and displacement time-history curves of smartphone and traditional sensors are provided and compared to prove the feasibility of the monitoring on frame under earthquake excitations by smartphone.

  15. Accuracy of a novel noninvasive transdermal continuous glucose monitor in critically ill patients.

    Science.gov (United States)

    Saur, Nicole M; England, Michael R; Menzie, Wayne; Melanson, Ann Marie; Trieu, My-Quyen; Berlin, Jason; Hurley, James; Krystyniak, Keith; Kongable, Gail L; Nasraway, Stanley A

    2014-09-01

    Stress hyperglycemia and hypoglycemia are associated with increased morbidity and mortality in the critically ill. Intermittent, random blood glucose (BG) measurements can miss episodes of hyper- and hypoglycemia. The purpose of this study was to determine the accuracy of the Symphony® continuous glucose monitor (CGM) in critically ill cardiac surgery patients. Fifteen adult cardiac surgery patients were evaluated immediately postoperatively in the intensive care unit. Prelude® SkinPrep prepared the skin and a sensor was applied to 2 test sites on each subject to monitor interstitial fluid glucose. Reference BG was sampled at 30- to 60-minute intervals. The skin at the test sites was inspected for adverse effects. Accuracy of the retrospectively analyzed CGM data relative to reference BG values was determined using continuous glucose-error grid analysis (CG-EGA) and mean absolute relative difference (MARD). Using 570 Symphony CGM glucose readings paired with reference BG measurements, CG-EGA showed that 99.6% of the readings were within zones A and B. BG measurements ranged from 73 to 251 mg/dL. The MARD was 12.3%. No adverse device effects were reported. The Symphony CGM system is able to safely, continuously, and noninvasively monitor glucose in the transdermal interstitial fluid of cardiac surgery intensive care unit patients with accuracy similar to that reported with other CGM systems. Future versions of the system will need real-time data analysis, fast warm-up, and less frequent calibrations to be used in the clinical setting. © 2014 Diabetes Technology Society.

  16. Parameters of rumen fermentation in a continuously fed sheep: evidence of a microbial rumination pool.

    Science.gov (United States)

    Hungate, R E; Reichl, J; Prins, R

    1971-12-01

    The feed and feces of a continuously fed sheep were analyzed for carbon, hydrogen, and nitrogen, with oxygen as the remainder. The daily feed-feces weight difference was used as the reactant in an equation representing the rumen fermentation. The measured products were the daily production of volatile fatty acids (VFA), CH(4), CO(2), and ammonia. The carbon unaccounted for was assumed to be in the microbial cell material produced in the rumen and absorbed before reaching the feces. The ratio of C to H, O, and N in bacteria was used to represent the elemental composition of the microbes formed in the rumen fermentation, completing the following equation:C(20.03)H(36.99)O(17.406)N(1.345) + 5.65 H(2)O --> C(12)H(24)O(10.1) + 0.83 CH(4) VFA + 2.76 CO(2) + 0.50 NH(3) + C(4.44)H(8.88)O(2.35)N(0.785) microbial cells absorbed With C arbitrarily balanced and O balanced by appropriate addition of water, any error is reflected in the H. The H recovery was 98.5%. The turnover rate constant for rumen liquid equilibrating with polyethylene glycol (PEG) was 2.27 per day. Direct counts and volume measurements of the individual types of bacteria and protozoa in the rumen were used to calculate the total microbial cell volume in the rumen, not equilibrating with it. The dry matter in the rumen (582 g) and the nitrogen content (12.05) of the microbes in the rumen were estimated, the latter constituting 85% of the measured N in the rumen. Calculations for rumen dry matter and nitrogen turning over at the PEG rate introduce big discrepancies with other parameters; a rumination pool must be postulated. Its size and composition are estimated. Arguments are presented to support the view that dry matter and some of the microbes, chiefly the protozoa, do not leave the rumen at the PEG rate. One experiment with the same sheep fed twice daily showed significantly less production of microbial cells than did the continuous (each 2 hr) feeding. Analysis of the microbial cell yield suggests that

  17. Characterization of 4 years MagnetoTelluric monitoring data by studying the temporal behaviour of Alpha Stable Distribution Parameters

    Science.gov (United States)

    Siniscalchi, Agata; Romano, Gerardo; Barracano, Fabio; Balasco, Marianna; Tripaldi, Simona

    2017-04-01

    Analyzing a 4 years of a single site MT continuous monitoring data, a systematic variation of the MT transfer function estimates was observed in the [20-100 s] period range that was shown to be connected to the global geomagnetic activity, Ap index (Romano et al., 2014). The monitored period, from 2007 to 2011, includes the global minimum of solar activity which occurred in 2009 (low MT source amplitude). It was shown that the impedance robust estimations tend to stabilize when the Ap index exceed a value of 10. In order to exclude a possible dependence of the observed fluctuation on the presence of a local cultural noise source, for a shorter period ( 2 months) the monitoring data were also processed by using a remote site. Recently Chave (2012) demonstrated that MT data can be described by alpha stable distribution family that is characterized by four-parameters that must be empirically determined. The Gaussian distribution belongs to this family as a special case when one of the four parameter, α the tail thickness, is equal to 2. Following Chave (2016), MT data are typically stably distributed with the empirical observation that 0.8 ≤α ≤1.8. In order to better understand the observed dependence of the MT continuous monitoring on the global geomagnetic activity, here we present the results a re-analysis of the MT monitoring data with a two steps processing. In the first step, we characterize the time series of the Alpha Stable Distribution Parameters (ASDP) as obtained from the whole processing of the dataset with the aim of checking for possible connections between these last and the Ap index. In the second step, we estimate the ASDP by using only the samples which satisfy the mathematical range of existence of the normalized WAL (Weaver et al.,2000) considering these last as a diagnostic tool to detect which segments of the time series in the frequency domain are strongly contaminated by noise (WAL selection criterion). The comparison between the results

  18. Perspectives on monitoring gradual change across the continuity of Landsat sensors using time-series data

    Science.gov (United States)

    Vogelmann, James; Gallant, Alisa L.; Shi, Hua; Zhu, Zhe

    2016-01-01

    There are many types of changes occurring over the Earth's landscapes that can be detected and monitored using Landsat data. Here we focus on monitoring “within-state,” gradual changes in vegetation in contrast with traditional monitoring of “abrupt” land-cover conversions. Gradual changes result from a variety of processes, such as vegetation growth and succession, damage from insects and disease, responses to shifts in climate, and other factors. Despite the prevalence of gradual changes across the landscape, they are largely ignored by the remote sensing community. Gradual changes are best characterized and monitored using time-series analysis, and with the successful launch of Landsat 8 we now have appreciable data continuity that extends the Landsat legacy across the previous 43 years. In this study, we conducted three related analyses: (1) comparison of spectral values acquired by Landsats 7 and 8, separated by eight days, to ensure compatibility for time-series evaluation; (2) tracking of multitemporal signatures for different change processes across Landsat 5, 7, and 8 sensors using anniversary-date imagery; and (3) tracking the same type of processes using all available acquisitions. In this investigation, we found that data representing natural vegetation from Landsats 5, 7, and 8 were comparable and did not indicate a need for major modification prior to use for long-term monitoring. Analyses using anniversary-date imagery can be very effective for assessing long term patterns and trends occurring across the landscape, and are especially good for providing insights regarding trends related to long-term and continuous trends of growth or decline. We found that use of all available data provided a much more comprehensive level of understanding of the trends occurring, providing information about rate, duration, and intra- and inter-annual variability that could not be readily gleaned from the anniversary date analyses. We observed that using all

  19. Smart medical textiles with embedded optical fibre sensors for continuous monitoring of respiratory movements during MRI

    Science.gov (United States)

    Witt, J.; Narbonneau, F.; Schukar, M.; Krebber, K.; De Jonckheere, J.; Jeanne, M.; Kinet, D.; Paquet, B.; Depré, A.; D'Angelo, L. T.; Thiel, T.; Logier, R.

    2010-09-01

    We report on three respiration sensors based on pure optical technologies developed during the FP6 EU project OFSETH. The developed smart medical textiles can sense elongation up to 3%, while maintaining the stretching properties of the textile substrates for a good comfort of the patient. The sensors, based on silica and polymer fibre, are developed for monitoring of patients during MRI examination. The OFSETH harness allows a continuous measurement of respiration movements while all vitals organs are free for medical staff actions. The sensors were tested in MRI environment and on healthy adults.

  20. Automated modal tracking and fatigue assessment of a wind turbine based on continuous dynamic monitoring

    Directory of Open Access Journals (Sweden)

    Oliveira Gustavo

    2015-01-01

    Full Text Available The paper describes the implementation of a dynamic monitoring system at a 2.0 MW onshore wind turbine. The system is composed by two components aiming at the structural integrity and fatigue assessment. The first component enables the continuous tracking of modal characteristics of the wind turbine (natural frequency values, modal damping ratios and mode shapes in order to detect abnormal deviations of these properties, which may be caused by the occurrence of structural damage. On the other hand, the second component allows the estimation of the remaining fatigue lifetime of the structure based on the analysis of the measured cycles of structural vibration.

  1. Privacy and Security Issues Surrounding the Protection of Data Generated by Continuous Glucose Monitors.

    Science.gov (United States)

    Britton, Katherine E; Britton-Colonnese, Jennifer D

    2017-03-01

    Being able to track, analyze, and use data from continuous glucose monitors (CGMs) and through platforms and apps that communicate with CGMs helps achieve better outcomes and can advance the understanding of diabetes. The risks to patients' expectation of privacy are great, and their ability to control how their information is collected, stored, and used is virtually nonexistent. Patients' physical security is also at risk if adequate cybersecurity measures are not taken. Currently, data privacy and security protections are not robust enough to address the privacy and security risks and stymies the current and future benefits of CGM and the platforms and apps that communicate with them.

  2. A CMOS-Based Tactile Sensor for Continuous Blood Pressure Monitoring

    CERN Document Server

    Kirstein, K -U; Salo, T; Hagleitner, C; Vancura, T; Hierlemann, A

    2011-01-01

    A monolithic integrated tactile sensor array is presented, which is used to perform non-invasive blood pressure monitoring of a patient. The advantage of this device compared to a hand cuff based approach is the capability of recording continuous blood pressure data. The capacitive, membrane-based sensor device is fabricated in an industrial CMOS-technology combined with post-CMOS micromachining. The capacitance change is detected by a S?-modulator. The modulator is operated at a sampling rate of 128kS/s and achieves a resolution of 12bit with an external decimation filter and an OSR of 128.

  3. The Utility of Continuous Temperature Monitoring of Refrigerators in a Long-Term Care Facility.

    Science.gov (United States)

    Worz, Chad; Postolski, Josh; Williams, Kevin

    2017-04-01

    It is the current practice in most long-term care facilities to use manual logs when documenting refrigerator temperatures. This process is commonly associated with poor or fabricated compliance, little oversight, and documentation errors, both because of overt omissions and unsubstantiated values. It is also well-established that medication storage requirements are mandated by the Centers for Medicare & Medicaid Services (CMS). This analysis demonstrates the potential risk of poor cold-chain management of medications and establishes the possible utility of digitally recorded continuous temperature monitoring over manual logs. This small case-oriented review of a large nursing facility's storage process attempts to expose the risk associated with improper medication storage. The primary outcome of the study was to determine if a difference existed between temperature logs completed manually compared with those done with a continuous monitor. American Thermal Instruments (ATI) thermometers were placed into each of the existing refrigerators in a 147-bed nursing facility. Through a mobile app, the data recorded in each refrigerator were compiled into daily reports. Data were collected from a total of 12 refrigerators, 3 of which were medication refrigerators. Logging intervals were done over a 263-minute period and compiled the lowest recorded temperature, highest recorded temperature, and the average temperature for each refrigerator. In addition, reports showing the real-time results were compiled using the ATI DataNow service. All of the refrigerators analyzed had highest temperature recorded readings exceeding the maximum allowable temperature (50°F for refrigerator). All of the refrigerators had lowest temperature recorded readings below the minimum allowable temperature (32°F for refrigerators). All of the refrigerators also reported average temperatures outside of the allowable temperature range. The results necessitated the replacement of a refrigerator and

  4. Monitoring biodiesel reactions of soybean oil and sunflower oil using ultrasonic parameters

    Science.gov (United States)

    Figueiredo, M. K. K.; Silva, C. E. R.; Alvarenga, A. V.; Costa-Félix, R. P. B.

    2015-01-01

    Biodiesel is an innovation that attempts to substitute diesel oil with biomass. The aim of this paper is to show the development of a real-time method to monitor transesterification reactions by using low-power ultrasound and pulse/echo techniques. The results showed that it is possible to identify different events during the transesterification process by using the proposed parameters, showing that the proposed method is a feasible way to monitor the reactions of biodiesel during its fabrication, in real time, and with relatively low- cost equipment.

  5. Volcano Monitoring in Ecuador: Three Decades of Continuous Progress of the Instituto Geofisico - Escuela Politecnica Nacional

    Science.gov (United States)

    Ruiz, M. C.; Yepes, H. A.; Hall, M. L.; Mothes, P. A.; Ramon, P.; Hidalgo, S.; Andrade, D.; Vallejo Vargas, S.; Steele, A. L.; Anzieta, J. C.; Ortiz, H. D.; Palacios, P.; Alvarado, A. P.; Enriquez, W.; Vasconez, F.; Vaca, M.; Arrais, S.; Viracucha, G.; Bernard, B.

    2014-12-01

    In 1988, the Instituto Geofisico (IG) began a permanent surveillance of Ecuadorian volcanoes, and due to activity on Guagua Pichincha, SP seismic stations and EDM control lines were then installed. Later, with the UNDRO and OAS projects, telemetered seismic monitoring was expanded to Tungurahua, Cotopaxi, Cuicocha, Chimborazo, Antisana, Cayambe, Cerro Negro, and Quilotoa volcanoes. In 1992 an agreement with the Instituto Ecuatoriano de Electrificacion strengthened the monitoring of Tungurahua and Cotopaxi volcanoes with real-time SP seismic networks and EDM lines. Thus, background activity levels became established, which was helpful because of the onset of the 1999 eruptive activity at Tungurahua and Guagua Pichincha. These eruptions had a notable impact on Baños and Quito. Unrest at Cotopaxi volcano was detected in 2001-2002, but waned. In 2002 Reventador began its eruptive period which continues to the present and is closely monitored by the IG. In 2006 permanent seismic BB stations and infrasound sensors were installed at Tungurahua and Cotopaxi under a cooperative program supported by JICA, which allowed us to follow Tungurahua's climatic eruptions of 2006 and subsequent eruptions up to the present. Programs supported by the Ecuadorian Secretaria Nacional de Ciencia y Tecnologia and the Secretaria Nacional de Planificacion resulted in further expansion of the IG's monitoring infrastructure. Thermal and video imagery, SO2 emission monitoring, geochemical analyses, continuous GPS and tiltmeters, and micro-barometric surveillance have been incorporated. Sangay, Soche, Ninahuilca, Pululahua, and Fernandina, Cerro Azul, Sierra Negra, and Alcedo in the Galapagos Islands are now monitored in real-time. During this time, international cooperation with universities (Blaise Pascal & Nice-France, U. North Carolina, New Mexico Tech, Uppsala-Sweden, Nagoya, etc.), and research centers (USGS & UNAVCO-USA, IRD-France, NIED-Japan, SGC-Colombia, VAAC, MIROVA) has introduced

  6. Updating Parameters for Volcanic Hazard Assessment Using Multi-parameter Monitoring Data Streams And Bayesian Belief Networks

    Science.gov (United States)

    Odbert, Henry; Aspinall, Willy

    2014-05-01

    Evidence-based hazard assessment at volcanoes assimilates knowledge about the physical processes of hazardous phenomena and observations that indicate the current state of a volcano. Incorporating both these lines of evidence can inform our belief about the likelihood (probability) and consequences (impact) of possible hazardous scenarios, forming a basis for formal quantitative hazard assessment. However, such evidence is often uncertain, indirect or incomplete. Approaches to volcano monitoring have advanced substantially in recent decades, increasing the variety and resolution of multi-parameter timeseries data recorded at volcanoes. Interpreting these multiple strands of parallel, partial evidence thus becomes increasingly complex. In practice, interpreting many timeseries requires an individual to be familiar with the idiosyncrasies of the volcano, monitoring techniques, configuration of recording instruments, observations from other datasets, and so on. In making such interpretations, an individual must consider how different volcanic processes may manifest as measureable observations, and then infer from the available data what can or cannot be deduced about those processes. We examine how parts of this process may be synthesised algorithmically using Bayesian inference. Bayesian Belief Networks (BBNs) use probability theory to treat and evaluate uncertainties in a rational and auditable scientific manner, but only to the extent warranted by the strength of the available evidence. The concept is a suitable framework for marshalling multiple strands of evidence (e.g. observations, model results and interpretations) and their associated uncertainties in a methodical manner. BBNs are usually implemented in graphical form and could be developed as a tool for near real-time, ongoing use in a volcano observatory, for example. We explore the application of BBNs in analysing volcanic data from the long-lived eruption at Soufriere Hills Volcano, Montserrat. We discuss

  7. Improving catchment scale water quality modelling with continuous high resolution monitoring of metals in runoff

    Science.gov (United States)

    Saari, Markus; Rossi, Pekka; Blomberg von der Geest, Kalle; Mäkinen, Ari; Postila, Heini; Marttila, Hannu

    2017-04-01

    High metal concentrations in natural waters is one of the key environmental and health problems globally. Continuous in-situ analysis of metals from runoff water is technically challenging but essential for the better understanding of processes which lead to pollutant transport. Currently, typical analytical methods for monitoring elements in liquids are off-line laboratory methods such as ICP-OES (Inductively Coupled Plasma Optical Emission Spectroscopy) and ICP-MS (ICP combined with a mass spectrometer). Disadvantage of the both techniques is time consuming sample collection, preparation, and off-line analysis at laboratory conditions. Thus use of these techniques lack possibility for real-time monitoring of element transport. We combined a novel high resolution on-line metal concentration monitoring with catchment scale physical hydrological modelling in Mustijoki river in Southern Finland in order to study dynamics of processes and form a predictive warning system for leaching of metals. A novel on-line measurement technique based on micro plasma emission spectroscopy (MPES) is tested for on-line detection of selected elements (e.g. Na, Mg, Al, K, Ca, Fe, Ni, Cu, Cd and Pb) in runoff waters. The preliminary results indicate that MPES can sufficiently detect and monitor metal concentrations from river water. Water and Soil Assessment Tool (SWAT) catchment scale model was further calibrated with high resolution metal concentration data. We show that by combining high resolution monitoring and catchment scale physical based modelling, further process studies and creation of early warning systems, for example to optimization of drinking water uptake from rivers, can be achieved.

  8. Accuracy of continuous noninvasive hemoglobin monitoring for the prediction of blood transfusions in trauma patients.

    Science.gov (United States)

    Galvagno, Samuel M; Hu, Peter; Yang, Shiming; Gao, Cheng; Hanna, David; Shackelford, Stacy; Mackenzie, Colin

    2015-12-01

    Early detection of hemorrhagic shock is required to facilitate prompt coordination of blood component therapy delivery to the bedside and to expedite performance of lifesaving interventions. Standard physical findings and vital signs are difficult to measure during the acute resuscitation stage, and these measures are often inaccurate until patients deteriorate to a state of decompensated shock. The aim of this study is to examine a severely injured trauma patient population to determine whether a noninvasive SpHb monitor can predict the need for urgent blood transfusion (universal donor or additional urgent blood transfusion) during the first 12 h of trauma patient resuscitation. We hypothesize that trends in continuous SpHb, combined with easily derived patient-specific factors, can identify the immediate need for transfusion in trauma patients. Subjects were enrolled if directly admitted to the trauma center, >17 years of age, and with a shock index (heart rate/systolic blood pressure) >0.62. Upon admission, a Masimo Radical-7 co-oximeter sensor (Masimo Corporation, Irvine, CA) was applied, providing measurement of continuous non-invasive hemoglobin (SpHb) levels. Blood was drawn and hemoglobin concentration analyzed and conventional pulse oximetry photopletysmograph signals were continuously recorded. Demographic information and both prehospital and admission vital signs were collected. The primary outcome was transfusion of at least one unit of packed red blood cells within 24 h of admission. Eight regression models (C1-C8) were evaluated for the prediction of blood use by comparing area under receiver operating curve (AUROC) at different time intervals after admission. 711 subjects had continuous vital signs waveforms available, to include heart rate (HR), SpHb and SpO2 trends. When SpHb was monitored for 15 min, SpHb did not increase AUROC for prediction of transfusion. The highest ROC was recorded for model C8 (age, sex, prehospital shock index, admission

  9. Continuous, Large-Scale Processing of Seismic Archives for High-Resolution Monitoring of Seismic Activity and Seismogenic Properties

    Science.gov (United States)

    Waldhauser, F.; Schaff, D. P.

    2012-12-01

    Archives of digital seismic data recorded by seismometer networks around the world have grown tremendously over the last several decades helped by the deployment of seismic stations and their continued operation within the framework of monitoring earthquake activity and verification of the Nuclear Test-Ban Treaty. We show results from our continuing effort in developing efficient waveform cross-correlation and double-difference analysis methods for the large-scale processing of regional and global seismic archives to improve existing earthquake parameter estimates, detect seismic events with magnitudes below current detection thresholds, and improve real-time monitoring procedures. We demonstrate the performance of these algorithms as applied to the 28-year long seismic archive of the Northern California Seismic Network. The tools enable the computation of periodic updates of a high-resolution earthquake catalog of currently over 500,000 earthquakes using simultaneous double-difference inversions, achieving up to three orders of magnitude resolution improvement over existing hypocenter locations. This catalog, together with associated metadata, form the underlying relational database for a real-time double-difference scheme, DDRT, which rapidly computes high-precision correlation times and hypocenter locations of new events with respect to the background archive (http://ddrt.ldeo.columbia.edu). The DDRT system facilitates near-real-time seismicity analysis, including the ability to search at an unprecedented resolution for spatio-temporal changes in seismogenic properties. In areas with continuously recording stations, we show that a detector built around a scaled cross-correlation function can lower the detection threshold by one magnitude unit compared to the STA/LTA based detector employed at the network. This leads to increased event density, which in turn pushes the resolution capability of our location algorithms. On a global scale, we are currently building

  10. Design of GLP lab environment parameters monitor system based on Schneider PLC

    Science.gov (United States)

    Lian, Xiaoqin; Xu, Huihui; Duan, Zhengang; Zhang, Yong

    2008-10-01

    According to the technological process and the requirement for system control of the GLP Laboratory, an automatic system is designed to monitor and control over the environment parameters of the GLP laboratory. The system is composed of a programmable controller and touching screen as the processing unit. The Schneider PLC TSX P57303 controller with its counterpart input/output modules is adopted as the hardware platform and the Schneider PL7-MICRO/WIN as the software platform. This paper presents the main flow process design of the control system. The test results show that the control system can run automatically and switch mutually under different modes, and the functions such as monitor and control over the environment parameters of the GLP laboratory are realized.

  11. Perceived accuracy in continuous glucose monitoring: understanding the impact on patients.

    Science.gov (United States)

    Polonsky, William H; Hessler, Danielle

    2015-03-01

    In terms of accuracy and reliability, the technology of real-time (RT) continuous glucose monitoring (CGM) is advancing quickly. Still, current devices are imperfect; as a result, patient complaints and frustrations are not uncommon. How do patients' perceptions of device accuracy affect their experience with RT-CGM? In this article, we argue that patients' satisfaction, or dissatisfaction, with accuracy has a major impact on how much they are likely to trust the device and how confident they may feel in using the information that is displayed. The available data suggest that greater satisfaction with accuracy is linked to better RT-CGM adherence, more confident and aggressive insulin adjustments, improvements in quality of life, reduced reliance on self-monitoring of blood glucose, and--potentially--less alarm fatigue. As the technology continues to mature, RT-CGM will become increasingly accurate and patients' confidence and trust in the available devices will likely grow, leading to greater uptake and more proactive use of RT-CGM. © 2014 Diabetes Technology Society.

  12. Ablation for atrial fibrillation during mitral valve surgery: 1-year results through continuous subcutaneous monitoring.

    Science.gov (United States)

    Bogachev-Prokophiev, Alexandr; Zheleznev, Sergey; Romanov, Alexander; Pokushalov, Evgeny; Pivkin, Alexey; Corbucci, Giorgio; Karaskov, Alexander

    2012-07-01

    Continuous monitoring of cardiac rhythm may play an important role in measuring the true symptomatic/asymptomatic atrial fibrillation (AF) burden and improve the management of anti-arrhythmic and anti-thrombotic therapies. Forty-seven patients with mitral valve disease and longstanding persistent AF (LSPAF) underwent a left atrial maze procedure with bipolar radiofrequency and valve surgery. The follow-up data recorded by an implanted loop recorder were analysed after 3, 6 and 12 months. On discharge, 40 (85.1%) patients were in stable sinus rhythm, as documented by in-office electrocardiography (ECG), 4 (8.5%) were in pacemaker rhythm and 3 (6.4%) were in AF. One (2.1%) patient died after 7 months. On 12-month follow-up examination, 30 (65.2%) patients had an AF burden 0.5%. Two (4.3%) patients with AF recurrences were completely asymptomatic. Among the symptomatic events stored by the patients, only 27.6% was confirmed as genuine AF recurrences according to the concomitant ECG recorded by the implanted loop recorder. A concomitant bipolar maze procedure during mitral valve surgery is effective in treating AF, as proved by detailed 1-year continuous monitoring.

  13. Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring.

    Science.gov (United States)

    Holzinger, Ulrike; Warszawska, Joanna; Kitzberger, Reinhard; Herkner, Harald; Metnitz, Philipp G H; Madl, Christian

    2009-08-01

    To evaluate the impact of circulatory shock requiring norepinephrine therapy on the accuracy and reliability of a subcutaneous continuous glucose monitoring system (CGMS) in critically ill patients. A prospective, validation study of a medical intensive care unit at a university hospital was carried out. Continuous glucose monitoring was performed subcutaneously in 50 consecutive patients on intensive insulin therapy (IIT), who were assessed according to the a priori strata of circulatory shock requiring norepinephrine therapy or not. A total of 736 pairs of sensor glucose (SG)/blood glucose (BG) values were analysed (502 without and 234 with norepinephrine therapy). For all values, repeated measures Bland-Altman analysis showed a mean difference of 0.08 mmol/l (limits of agreement: -1.26 and 1.43 mmol/l). Circulatory shock requiring norepinephrine therapy did not influence the relation of arterial BG with SG in a multivariable random effects linear regression analysis. The covariates norepinephrine dose, body mass index (BMI), glucose level and severity of illness also had no influence. Insulin titration grid analysis showed that 98.6% of the data points were in the acceptable treatment zone. No data were in the life-threatening zone. Circulatory shock requiring norepinephrine therapy, as well as other covariates, had no influence on the accuracy and reliability of the CGMS in critically ill patients.

  14. Online Decorrelation of Humidity and Temperature in Chemical Sensors for Continuous Monitoring

    CERN Document Server

    Huerta, Ramon; Fonollosa, Jordi; Rulkov, Nikolai F; Rodriguez-Lujan, Irene

    2016-01-01

    A method for online decorrelation of chemical sensor readings from the effects of environmental humidity and temperature variations is proposed. The goal is to improve the accuracy of electronic nose measurements for continuous monitoring by processing data from simultaneous readings of environmental humidity and temperature. The electronic nose setup built for this study included eight different metal-oxide sensors, temperature and humidity sensors with a wireless communication link to PC. This wireless electronic nose was used to monitor air for two years in the residence of one of the authors and collected data continuously during 510 full days with a sampling rate of 2 samples per second. To estimate the effects of variations in air humidity and temperature on the chemical sensors readings, we used a standard energy band model for an n-type metal-oxide sensor. The main assumption of the model is that variations in sensor conductivity can be expressed as a nonlinear function of changes in the semiconductor...

  15. An all fiber-optic multi-parameter structure health monitoring system.

    Science.gov (United States)

    Hu, Chennan; Yu, Zhihao; Wang, Anbo

    2016-09-01

    In this work, we present an all fiber-optics based multi-parameter structure health monitoring system, which is able to monitor strain, temperature, crack and thickness of metal structures. This system is composed of two optical fibers, one for laser-acoustic excitation and the other for acoustic detection. A nano-second 1064 nm pulse laser was used for acoustic excitation and a 2 mm fiber Bragg grating was used to detect the acoustic vibration. The feasibility of this system was demonstrated on an aluminum test piece by the monitoring of the temperature, strain and thickness changes, as well as the appearance of an artificial crack. The multiplexing capability of this system was also preliminarily demonstrated.

  16. A wearable diffuse reflectance sensor for continuous monitoring of cutaneous blood content

    Energy Technology Data Exchange (ETDEWEB)

    Zakharov, P; Talary, M S; Caduff, A [Solianis Monitoring AG, Leutschenbachstrasse 46, CH-8050 Zuerich (Switzerland)], E-mail: andreas.caduff@solianis.com

    2009-09-07

    An optical diffuse reflectance sensor for characterization of cutaneous blood content and optimized for continuous monitoring has been developed as part of a non-invasive multisensor system for glucose monitoring. A Monte Carlo simulation of the light propagation in the multilayered skin model has been performed in order to estimate the optimal geometrical separation of the light source and detector for skin and underlying tissue. We have observed that the pathlength within the upper vascular plexus of the skin which defines the sensor sensitivity initially grows with increasing source-detector distance (SDD) before reaching a maximum at 3.5 mm and starts to decay with further increase. At the same time, for distances above 2.4 mm, the sensor becomes sensitive to muscle blood content, which decreases the specificity to skin perfusion monitoring. Thus, the SDDs in the range from 1.5 mm to 2.4 mm satisfy the requirements of sensor sensitivity and specificity. The hardware implementation of the system has been realized and tested in laboratory experiments with a venous occlusion procedure and in an outpatient clinical study in 16 patients with type 1 diabetes mellitus. For both testing procedures, the optical sensor demonstrated high sensitivity to perfusion change provoking events. The general build-up of cutaneous blood under the sensor has been observed which can be associated with pressure-induced vasodilation as a response to the sensor application.

  17. Continuous glucose monitoring and trend accuracy: news about a trend compass.

    Science.gov (United States)

    Signal, Matthew; Gottlieb, Rebecca; Le Compte, Aaron; Chase, J Geoffrey

    2014-09-01

    Continuous glucose monitoring (CGM) devices are being increasingly used to monitor glycemia in people with diabetes. One advantage with CGM is the ability to monitor the trend of sensor glucose (SG) over time. However, there are few metrics available for assessing the trend accuracy of CGM devices. The aim of this study was to develop an easy to interpret tool for assessing trend accuracy of CGM data. SG data from CGM were compared to hourly blood glucose (BG) measurements and trend accuracy was quantified using the dot product. Trend accuracy results are displayed on the Trend Compass, which depicts trend accuracy as a function of BG. A trend performance table and Trend Index (TI) metric are also proposed. The Trend Compass was tested using simulated CGM data with varying levels of error and variability, as well as real clinical CGM data. The results show that the Trend Compass is an effective tool for differentiating good trend accuracy from poor trend accuracy, independent of glycemic variability. Furthermore, the real clinical data show that the Trend Compass assesses trend accuracy independent of point bias error. Finally, the importance of assessing trend accuracy as a function of BG level is highlighted in a case example of low and falling BG data, with corresponding rising SG data. This study developed a simple to use tool for quantifying trend accuracy. The resulting trend accuracy is easily interpreted on the Trend Compass plot, and if required, performance table and TI metric. © 2014 Diabetes Technology Society.

  18. Biofouling and the continuous monitoring of underwater light from a seagrass perspective

    Science.gov (United States)

    Onuf, C.P.

    2006-01-01

    For more than a decade, inexpensive electronic instruments have made continuous underwater light monitoring an integral part of many seagrass studies. Although biofouling, if not controlled, compromises the utility of the record. A year-long assessment of the time course of sensor fouling, in the Laguna Madre of Texas established that light transmitted through the fouling layer after 2 wk of exposure exceeded 90% except for a 6-8 wk period in May and June. On that basis, a 2-wk interval was chosen for routine servicing. Subsequent monitoring proved this choice to be grossly in error. The period of sub-90% transmittance after 2 wk extended to 4-6 mo annually over the next 3 yr. Fouling was strongly correlated with temperature, ambient light, and year. Since an algal bloom of 7-yr duration finally waned during this study, increased ambient light seemed most likely to explain increased fouling later in the study. The explanatory value of light was less than temperature or year in multiple regression, requiring some other explanation of the date effect than change in ambient light. Allelopathic and suspension-feeding depressant effects of the brown tide are offered as the most likely cause of unusually low fouling in the first year. Biofouling was so unpredictable and rapid in this study that at least weekly maintenance would be required to assure reliability of the light monitoring record. ?? 2006 Estuarine Research Federation.

  19. An intra-body molecular communication networks framework for continuous health monitoring and diagnosis.

    Science.gov (United States)

    Chahibi, Youssef; Balasingham, Ilangko

    2015-01-01

    Intra-body communication networks are designed to interconnect nano- or micro-sized sensors located inside the body for health monitoring and drug delivery. The most promising solutions are made of implanted nanosensors to timely monitor the body for the presence of specific diseases and pronounce a diagnosis without the intervention of a physician. In this manner, several deadly health conditions such as heart attacks are avoided through the early in vivo detection of their biomarkers. In reality, nanosensors are challenged by the individual specificities, molecular noise, limited durability, and low energy resources. In this paper, a framework is proposed for estimating and detecting diseases and localizing the nanosensors. This framework is based on molecular communication, a novel communication paradigm where information is conveyed through molecules. Through the case study of the shedding of endothelial cells as an early biomarker for heart attack, the intra-body molecular communication networks framework is shown to resolve major issues with in vivo nanosensors and lay the foundations of low-complexity biomedical signal processing algorithms for continuous disease monitoring and diagnosis.

  20. A wearable diffuse reflectance sensor for continuous monitoring of cutaneous blood content

    Science.gov (United States)

    Zakharov, P.; Talary, M. S.; Caduff, A.

    2009-09-01

    An optical diffuse reflectance sensor for characterization of cutaneous blood content and optimized for continuous monitoring has been developed as part of a non-invasive multisensor system for glucose monitoring. A Monte Carlo simulation of the light propagation in the multilayered skin model has been performed in order to estimate the optimal geometrical separation of the light source and detector for skin and underlying tissue. We have observed that the pathlength within the upper vascular plexus of the skin which defines the sensor sensitivity initially grows with increasing source-detector distance (SDD) before reaching a maximum at 3.5 mm and starts to decay with further increase. At the same time, for distances above 2.4 mm, the sensor becomes sensitive to muscle blood content, which decreases the specificity to skin perfusion monitoring. Thus, the SDDs in the range from 1.5 mm to 2.4 mm satisfy the requirements of sensor sensitivity and specificity. The hardware implementation of the system has been realized and tested in laboratory experiments with a venous occlusion procedure and in an outpatient clinical study in 16 patients with type 1 diabetes mellitus. For both testing procedures, the optical sensor demonstrated high sensitivity to perfusion change provoking events. The general build-up of cutaneous blood under the sensor has been observed which can be associated with pressure-induced vasodilation as a response to the sensor application.

  1. Circulating miRNA-155 is realted to blood pressure monitoring parameters

    Institute of Scientific and Technical Information of China (English)

    WU Ying; HUANG Yu-qing; HUANG Cheng; LI Jie; CAI An-ping; YU Xue-ju; ZHOU Dan

    2016-01-01

    Background Studies have shown that miRNA-155 played an important role in the process of development of hypertension.However,there is no date about miRNA-155 and blood pressure monitoring parameters.Therefore,we examined whether in hypertensive patients the expression level of plasma miRNA-155 related to 24-h ambulatory blood pressure monitoring (ABPM) parameters.Methods A cohort of adult patients scheduled to receive physical examination,office and ambulatory blood pressure monitoring.Quantitative reverse transcriptase polymerase chain reaction (qRT-PCR) was used to evaluate the expression of selected miRNA-155.The miRNA-155 expression level correlation between blood pressure parameters was assessed using the Spearman correlation coefficient.Results Fifty four essential hypertension patients (25 men;mean age,53.28 ± 9.52 years) and thirty healthy volunteers (15 men;mean age,53.03 ± 5.87 years) were included.We observed higher expression level of miRNA-155 (32.31 ± 2.85 vs 27.21 ± 1.59,P < 0.001) in hypertensive patients compared to healthy control individuals.MiRNA-155 expression level showed significant positive correlation with 24 h Daytime SBP (r =0.681,P < 0.001),24 h Daytime DBP (r =0.473,P < 0.001),24 h Daytime PP (r =0.565,P < 0.001) and dipping (r =0.257,P =0.018),respectively.Conclusions Our study showed that miRNA-155 expression level was associated positively with daytime blood pressure monitoring parameters,as well as blood pressure variability,indicating a possible implication of miRNA-155 in the pathogenesis of hypertension.

  2. Therapeutic Drug Monitoring in Neonatal HSV Infection on Continuous Renal Replacement Therapy.

    Science.gov (United States)

    Funaki, Takanori; Miyata, Ippei; Shoji, Kensuke; Enomoto, Yuki; Sakamoto, Seisuke; Kasahara, Mureo; Miyairi, Isao

    2015-07-01

    Optimal acyclovir dosing under continuous renal replacement therapy (CRRT) in neonates is unknown. We monitored serum acyclovir levels and herpes simplex virus 1 (HSV-1) DNA levels in a neonate with disseminated HSV-1 infection and renal failure undergoing CRRT. A full-term, 5-day-old female presented with a 2-day history of lethargy and fever. She developed fulminant hepatitis and was diagnosed with HSV-1 infection by real-time polymerase chain reaction. Acyclovir was initiated at 60 mg/kg/day, which was lowered to 20 mg/kg/day because of development of renal failure. She was placed on continuous hemodialysis. Acyclovir dosing was adjusted according to serum acyclovir levels, and HSV-1 viral load was sequentially monitored. Semiquantification of serum HSV-1 levels was performed by real-time polymerase chain reaction. Acyclovir levels were measured by using liquid chromatography-tandem mass spectrometry. Acyclovir was administered at 20 mg/kg intravenously over 1 hour; peak concentration was 18.9 μg/mL. The half-life of acyclovir was estimated to be 2 to 3 h. Viral load remained high during dosing every 24 hours, with a decline of 0.17 log copies/24 hours. Acyclovir dosing was changed to 20 mg/kg/dose every 8 hours, with an average viral load decline of 0.44 log copies/24 hours. Despite the guideline recommendation of 24-hour redosing, acyclovir was dialyzed at a rate that resulted in suboptimal treatment. Individual therapeutic drug monitoring for acyclovir and dosing adjustment may be required to optimize therapy for patients undergoing CRRT. Copyright © 2015 by the American Academy of Pediatrics.

  3. A novel system for continuous, real-time monitoring of heart motion signals.

    Science.gov (United States)

    Dori, Guy; Schliamser, Jorge E; Lichtenstein, Oscar; Anshelevich, Ilia; Flugelman, Moshe Y

    2017-03-29

    Understanding cardiac mechanics is important for developing cardiac therapies. Current modalities for assessing cardiac mechanics sample patient's heart at specific heart rate, contractility, preload, and afterload. The objective of this study was to test the feasibility of a novel system composed of intra-cardiac leads equipped with an inertial module chip (3D accelerometers and 3D gyroscopes) in monitoring continuous heart motion. In this descriptive study, four healthy pigs were anesthetized and instrumented with motion-sensitive intra-cardiac leads; the temporal correlation between signals from motion sensors and tissue Doppler from the chest wall were studied; changes in real-time heart accelerations (ACC) and angular velocity (ANGV) were reported as percentages of change from baseline. Heart motion signals were sensed continuously from the right ventricular apex (RVa) and coronary sinus (CS). Volume expansion did not produce significant changes in the ACC and ANGV signals. Increasing heart rate increased the peak systolic ACC signal recorded from RVa and CS by 94 and 76%, respectively, and increased both peak systolic (61% RVa and 27% CS) and diastolic ANGV (200% CS vs. 31% RVa). Epinephrine administration increased peak systolic ACC signals at both sites (246% RVa; 331% CS). Peak systolic and diastolic ANGV increased in response to epinephrine (systolic: 198% RVa and 175% CS; diastolic: 723% CS and 89% RVa) (p = 0.125 for all changes expressed in percent). Temporal correlation between the ANGV signal and tissue Doppler signal was detected throughout all interventions. A novel system for continuously monitoring heart motion signals from within the heart was presented. Heart motion signals in response to physiologic manipulations were characterized.

  4. Integrated insulin pump therapy with continuous glucose monitoring for improved adherence: technology update

    Directory of Open Access Journals (Sweden)

    Tumminia A

    2015-09-01

    Full Text Available Andrea Tumminia,1 Laura Sciacca,1 Lucia Frittitta,1 Sebastiano Squatrito,1 Riccardo Vigneri,2 Rosario Le Moli,1 Letizia Tomaselli2 1Endocrinology, Department of Clinical and Experimental Medicine, University of Catania, Garibaldi-Nesima Hospital, Catania, Italy; 2Endocrinology, Garibaldi-Nesima Hospital, Catania, Italy Abstract: Insulin pump therapy combined with real-time continuous glucose monitoring, known as sensor-augmented pump (SAP therapy, has been shown to improve metabolic control and to reduce the rate of hypoglycemia in adults with type 1 diabetes compared to multiple daily injections or standard continuous subcutaneous insulin infusion. Glycemic variability is also reduced in patients on SAP therapy. This approach allows patients to monitor their glucose levels being informed of glycemic concentration and trend. Trained diabetic patients, therefore, can appropriately modify insulin infusion and/or carbohydrate intake in order to prevent hypo- or hyperglycemia. For these reasons, SAP therapy is now considered the gold standard for type 1 diabetes treatment. To be clinically effective, however, devices and techniques using advanced technology should not only have the potential to theoretically ameliorate metabolic control, but also be well accepted by patients in terms of satisfaction and health-related quality of life, because these factors will improve treatment adherence and consequently overall outcome. SAP therapy is generally well tolerated by patients; however, many clinical trials have identified significant noncompliance in the use of this device, most notably in the pediatric and adolescent populations. In this review we aim to analyze the main reasons for good or poor adherence to SAP therapy and to provide useful tips in order to fully benefit from this kind of novel therapeutic approach. Keywords: sensor-augmented insulin pump therapy, type 1 diabetes, quality of life, patient adherence, continuous subcutaneous insulin

  5. Continuous Dep endence of Bounded Φ-variation Solutions on Parameter for a Class of Discontinuous Systems

    Institute of Scientific and Technical Information of China (English)

    MA Xue-min; LI Bao-lin; LIN Chang-wei

    2015-01-01

    The functions of bounded Φ-variation are development and generalization of bounded variation functions in the usual sense.Henstock-Kurzweil integral is a very useful tool for some discontinuous systems. In this paper, by using Henstock-Kurzweil integral, we establish theorems of continuous dependence of bounded Φ-variation solutions on parameter for a class of discontinuous systems on the base of Φ-function. These results are essential generalizations of continuous dependence of bounded variation solutions on parameter for the systems.

  6. Framework and implementation of a continuous network-wide health monitoring system for roadways

    Science.gov (United States)

    Wang, Ming; Birken, Ralf; Shahini Shamsabadi, Salar

    2014-03-01

    According to the 2013 ASCE report card America's infrastructure scores only a D+. There are more than four million miles of roads (grade D) in the U.S. requiring a broad range of maintenance activities. The nation faces a monumental problem of infrastructure management in the scheduling and implementation of maintenance and repair operations, and in the prioritization of expenditures within budgetary constraints. The efficient and effective performance of these operations however is crucial to ensuring roadway safety, preventing catastrophic failures, and promoting economic growth. There is a critical need for technology that can cost-effectively monitor the condition of a network-wide road system and provide accurate, up-to-date information for maintenance activity prioritization. The Versatile Onboard Traffic Embedded Roaming Sensors (VOTERS) project provides a framework and the sensing capability to complement periodical localized inspections to continuous network-wide health monitoring. Research focused on the development of a cost-effective, lightweight package of multi-modal sensor systems compatible with this framework. An innovative software infrastructure is created that collects, processes, and evaluates these large time-lapse multi-modal data streams. A GIS-based control center manages multiple inspection vehicles and the data for further analysis, visualization, and decision making. VOTERS' technology can monitor road conditions at both the surface and sub-surface levels while the vehicle is navigating through daily traffic going about its normal business, thereby allowing for network-wide frequent assessment of roadways. This deterioration process monitoring at unprecedented time and spatial scales provides unique experimental data that can be used to improve life-cycle cost analysis models.

  7. Continuous Multimodality Monitoring in Children after Traumatic Brain Injury-Preliminary Experience.

    Directory of Open Access Journals (Sweden)

    Adam M H Young

    Full Text Available Multimodality monitoring is regularly employed in adult traumatic brain injury (TBI patients where it provides physiologic and therapeutic insight into this heterogeneous condition. Pediatric studies are less frequent.An analysis of data collected prospectively from 12 pediatric TBI patients admitted to Addenbrooke's Hospital, Pediatric Intensive Care Unit (PICU between August 2012 and December 2014 was performed. Patients' intracranial pressure (ICP, mean arterial pressure (MAP, and cerebral perfusion pressure (CPP were monitored continuously using brain monitoring software ICM+®, Pressure reactivity index (PRx and 'Optimal CPP' (CPPopt were calculated. Patient outcome was dichotomized into survivors and non-survivors.At 6 months 8/12 (66% of the cohort survived the TBI. The median (±IQR ICP was significantly lower in survivors 13.1±3.2 mm Hg compared to non-survivors 21.6±42.9 mm Hg (p = 0.003. The median time spent with ICP over 20 mm Hg was lower in survivors (9.7+9.8% vs 60.5+67.4% in non-survivors; p = 0.003. Although there was no evidence that CPP was different between survival groups, the time spent with a CPP close (within 10 mm Hg to the optimal CPP was significantly longer in survivors (90.7±12.6% compared with non-survivors (70.6±21.8%; p = 0.02. PRx provided significant outcome separation with median PRx in survivors being 0.02±0.19 compared to 0.39±0.62 in non-survivors (p = 0.02.Our observations provide evidence that multi-modality monitoring may be useful in pediatric TBI with ICP, deviation of CPP from CPPopt, and PRx correlating with patient outcome.

  8. [Hardware-software system for monitoring parameters and characteristics of X-ray computer tomographs under operation conditions].

    Science.gov (United States)

    Blinov, N N; Zelikman, M I; Kruchinin, S A

    2007-01-01

    The results of testing of hardware and software for monitoring parameters (mean number of CT units, noise, field uniformity, high-contrast spatial resolution, layer width, dose) and characteristics (modulation transfer function) of X-ray computer tomographs are presented. The developed hardware and software are used to monitor the stability of X-ray computer tomograph parameters under operation conditions.

  9. A theoretical framework for convergence and continuous dependence of estimates in inverse problems for distributed parameter systems

    Science.gov (United States)

    Banks, H. T.; Ito, K.

    1988-01-01

    Numerical techniques for parameter identification in distributed-parameter systems are developed analytically. A general convergence and stability framework (for continuous dependence on observations) is derived for first-order systems on the basis of (1) a weak formulation in terms of sesquilinear forms and (2) the resolvent convergence form of the Trotter-Kato approximation. The extension of this framework to second-order systems is considered.

  10. A Device for Fetal Monitoring by Means of Control Over Cardiovascular Parameters Based on Acoustic Data

    Science.gov (United States)

    Khokhlova, L. A.; Seleznev, A. I.; Zhdanov, D. S.; Zemlyakov, I. Yu; Kiseleva, E. Yu

    2016-01-01

    The problem of monitoring fetal health is topical at the moment taking into account a reduction in the level of fertile-age women's health and changes in the concept of perinatal medicine with reconsideration of live birth criteria. Fetal heart rate monitoring is a valuable means of assessing fetal health during pregnancy. The routine clinical measurements are usually carried out by the means of ultrasound cardiotocography. Although the cardiotocography monitoring provides valuable information on the fetal health status, the high quality ultrasound devices are expensive, they are not available for home care use. The recommended number of measurement is also limited. The passive and fully non-invasive acoustic recording provides an alternative low-cost measurement method. The article describes a device for fetal and maternal health monitoring by analyzing the frequency and periodicity of heart beats by means of acoustic signal received on the maternal abdomen. Based on the usage of this device a phonocardiographic fetal telemedicine system, which will allow to reduce the antenatal fetal mortality rate significantly due to continuous monitoring over the state of fetus regardless of mother's location, can be built.

  11. Inter-observer agreement of a multi-parameter campsite monitoring program on the Dixie National Forest, Utah

    Science.gov (United States)

    Nicholas J. Glidden; Martha E. Lee

    2007-01-01

    Precision is crucial to campsite monitoring programs. Yet, little empirical research has ever been published on the level of precision of this type of monitoring programs. The purpose of this study was to evaluate the level of agreement between observers of campsite impacts using a multi-parameter campsite monitoring program. Thirteen trained observers assessed 16...

  12. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  13. Monitoring of Interaction-Point Parameters Using the 3-Dimensional Luminosity Distribution Measured at PEP-II

    Energy Technology Data Exchange (ETDEWEB)

    Viaud, B.F.; /Montreal U.; Kozanecki, W.; /DAPNIA, Saclay; O' Grady, C.; Thompson, J.; Weaver, M.; /SLAC

    2006-07-28

    The 3-D luminosity distribution at the IP of the SLAC B-Factory is monitored using e{sup +}e{sup -} {yields} e{sup +}e{sup -}, {mu}{sup +}{mu}{sup -} events reconstructed online in the BABAR detector. The transverse centroid and spatial orientation of the luminosity ellipsoid reliably monitor IP orbit drifts. The longitudinal centroid is sensitive to small variations in the average relative RF phase of the beams and provides a detailed measurement of the phase transient along the bunch train. The longitudinal luminosity distribution depends on the e{sup +,-} overlap bunch length and the vertical IP {beta}-functions. Relative variations in horizontal luminous size are detectable at the micron level. In addition to continuous on-line monitoring of all the parameters above, we performed detailed studies of their variation along the bunch train to investigate a temporary luminosity degradation. We also compare {beta}*{sub y} measurements, collected over a year of high-luminosity operation, with HER and LER lattice functions measured by resonant transverse excitation. Our bunch-length measurements are consistent with those obtained by other methods and provide direct evidence for bunch-length modulation.

  14. The Ancona Early Warning Centre, Instrumentation and Continuous Monitoring of the Landslide

    Science.gov (United States)

    Cardellini, S.

    2013-12-01

    The 'Grande frana di Ancona' is an deep-seated landslide reactivated in 1982 after a long period of precipitation. The landslide involves clay and silty clay layers (Pliocene-Pleistocene), fractured with different OCR parameter, alternated with thin sand levels. Overlapped sliding zones are active (maximum depth: 100-120 m, maximum depth 1982 event is 75 m bgl). All the investigations aimed at the consolidation preliminary design in 2000, but the plan concluded that a final consolidation was impossible. Ancona Administration decided then to 'live with the landslide' reducing nevertheless the risk for the people living there. In 2002 a regional law was specifically issued for the people living in the landslide, to give Ancona Administration the responsibility of creating an Early Warning System and an Emergency Plan for people. It's active a surface monitoring system based on 7 total stations and 33 geodetic GPS integrated by a subsurface in place geotechnical system based on 3 DMS multiparametric columns installed down to 95 m depth. Surface Monitoring system The combination of the different instruments: GPS, Automatic Robotic Stations and the clinometric sensors allows us to monitor in the 3D (3D, X, Y, Z) a great number of points previously identified, to keep them under supervision with different measuring technical and from different control positions. The adoption of the geodetic GPS at dual frequency assure an high quality of the GPS measures, and a greater versatility at all the system. The measuring cycle is set up on 30 minutes, but in emergency or after a long rainy period, the system can operate on every points of the dual frequency GPS net also in Real Time RTK, and with the 7 Automatic Robotic Stations. Geotechnical monitoring (DMS) The in place Geotechnical Monitoring System DMS (patents and trade mark CSG srl -Italy) was installed in February 2009. It is made by n°3 Modular Dynamic System columns positioned inside borehole 100 m depth. DMS columns

  15. Are physical activity studies in Hispanics meeting reporting guidelines for continuous monitoring technology? A systematic review.

    Science.gov (United States)

    Layne, Charles S; Parker, Nathan H; Soltero, Erica G; Rosales Chavez, José; O'Connor, Daniel P; Gallagher, Martina R; Lee, Rebecca E

    2015-09-18

    Continuous monitoring technologies such as accelerometers and pedometers are the gold standard for physical activity (PA) measurement. However, inconsistencies in use, analysis, and reporting limit the understanding of dose-response relationships involving PA and the ability to make comparisons across studies and population subgroups. These issues are particularly detrimental to the study of PA across different ethnicities with different PA habits. This systematic review examined the inclusion of published guidelines involving data collection, processing, and reporting among articles using accelerometers or pedometers in Hispanic or Latino populations. English (PubMed; EbscoHost) and Spanish (SCIELO; Biblioteca Virtual en Salud) articles published between 2000 and 2013 using accelerometers or pedometers to measure PA among Hispanics or Latinos were identified through systematic literature searches. Of the 253 abstracts which were initially reviewed, 57 met eligibility criteria (44 accelerometer, 13 pedometer). Articles were coded and reviewed to evaluate compliance with recommended guidelines (N = 20), and the percentage of accelerometer and pedometer articles following each guideline were computed and reported. On average, 57.1 % of accelerometer and 62.2 % of pedometer articles reported each recommended guideline for data collection. Device manufacturer and model were reported most frequently, and provision of instructions for device wear in Spanish was reported least frequently. On average, 29.6 % of accelerometer articles reported each guideline for data processing. Definitions of an acceptable day for inclusion in analyses were reported most frequently, and definitions of an acceptable hour for inclusion in analyses were reported least frequently. On average, 18.8 % of accelerometer and 85.7 % of pedometer articles included each guideline for data reporting. Accelerometer articles most frequently included average number of valid days and least frequently

  16. 40 CFR 63.9306 - What are my continuous parameter monitoring system (CPMS) installation, operation, and...

    Science.gov (United States)

    2010-07-01

    ... provides a representative temperature. (ii) Use a temperature sensor with a measurement sensitivity of 4... temperature chart recorder is used, it must have a measurement sensitivity in the minor division of at least... period of the emission capture system and add-on control device operation. (3) You must record...

  17. In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device

    NARCIS (Netherlands)

    De Lima Braga Lopes Cordeiro, Carlos; de Vries, M.G.; Ngabi, W; Oomen, P.E.; Cremers, T.I.F.H.; Westerink, B.H.C.

    2015-01-01

    Enzyme-based amperometric biosensors are widely used for monitoring key biomarkers. In experimental neuroscience there is a growing interest in in vivo continuous and simultaneous monitoring of metabolism-related biomarkers, like glucose, lactate and pyruvate. The use of multiplex biosensors will pr

  18. 40 CFR Table 7 to Subpart Bbbb of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Science.gov (United States)

    2010-07-01

    ... Emission Monitoring Systems (CEMS) 7 Table 7 to Subpart BBBB of Part 60 Protection of Environment...—Requirements for Continuous Emission Monitoring Systems (CEMS) For the following pollutants Use the following span values for CEMS Use the following performance specifications in appendix B of this part for...

  19. 40 CFR Table 4 to Subpart Ffff of... - Model Rule-Requirements for Continuous Emission Monitoring Systems (CEMS)

    Science.gov (United States)

    2010-07-01

    ... Emission Monitoring Systems (CEMS) 4 Table 4 to Subpart FFFF of Part 60 Protection of Environment...—Model Rule—Requirements for Continuous Emission Monitoring Systems (CEMS) As stated in § 60.3039, you... CEMS Use the following performance specifications (P.S.) in appendix B of this part for your CEMS...

  20. Noninvasive continuous versus intermittent arterial pressure monitoring: evaluation of the vascular unloading technique (CNAP device) in the emergency department.

    Science.gov (United States)

    Wagner, Julia Y; Prantner, Julia S; Meidert, Agnes S; Hapfelmeier, Alexander; Schmid, Roland M; Saugel, Bernd

    2014-01-29

    Monitoring cardiovascular function in acutely ill patients in the emergency department (ED) is of paramount importance. Arterial pressure (AP) is usually monitored using intermittent oscillometric measurements with an upper arm cuff. The vascular unloading technique (VUT) allows continuous noninvasive AP monitoring. In this study, we compare continuous AP measurements obtained by VUT with intermittent oscillometric AP measurements in ED patients. In addition, we aimed to investigate whether continuous noninvasive AP monitoring allows detection of relevant hypotensive episodes that might be missed with intermittent AP monitoring. In a German university hospital, 130 ED patients who required AP monitoring were analyzed in this prospective method comparison study. Continuous AP monitoring was performed using VUT (CNAP technology; CNSystems Medizintechnik AG, Graz, Austria) over a 2-hour period. The oscillometric AP values were recorded simultaneously every 15 minutes for the comparison of both methods. For statistical evaluation, Bland-Altman plots accounting for repeated AP measurements per individual were used. The mean difference (±standard deviation) between AP measurements obtained by VUT and oscillometric AP measurements was -5 mmHg (±22 mmHg) for systolic AP (SAP), -2 mmHg (±15 mmHg) for diastolic AP (DAP), and -6 mmHg (±16 mmHg) for mean AP (MAP), respectively. In the interval between two oscillometric measurements, the VUT device detected hypotensive episodes (≥4 minutes) defined as either SAP monitoring allows immediate recognition of clinically relevant hypotensive episodes, which are missed or only belatedly recognized with intermittent AP measurement.

  1. Early detection and treatment of myocardial ischaemia after operation using continual ambulatory arterial pressure monitoring and ECG ST segment analysis.

    Science.gov (United States)

    Edwards, N D; Troy, G; Yeo, W; Jackson, P; Reilly, C S

    1995-10-01

    We report a case in which the use of continual ambulatory arterial pressure monitoring and ECG ST-segment analysis allowed early detection and treatment of myocardial ischaemia in the postoperative period. We believe that this case illustrates the potential value of ambulatory monitoring in the early postoperative period in high-risk patients.

  2. Automatic semi-continuous accumulation chamber for diffuse gas emissions monitoring in volcanic and non-volcanic areas

    Science.gov (United States)

    Lelli, Matteo; Raco, Brunella; Norelli, Francesco; Virgili, Giorgio; Continanza, Davide

    2016-04-01

    Since various decades the accumulation chamber method is intensively used in monitoring activities of diffuse gas emissions in volcanic areas. Although some improvements have been performed in terms of sensitivity and reproducibility of the detectors, the equipment used for measurement of gas emissions temporal variation usually requires expensive and bulky equipment. The unit described in this work is a low cost, easy to install-and-manage instrument that will make possible the creation of low-cost monitoring networks. The Non-Dispersive Infrared detector used has a concentration range of 0-5% CO2, but the substitution with other detector (range 0-5000 ppm) is possible and very easy. Power supply unit has a 12V, 7Ah battery, which is recharged by a 35W solar panel (equipped with charge regulator). The control unit contains a custom programmed CPU and the remote transmission is assured by a GPRS modem. The chamber is activated by DataLogger unit, using a linear actuator between the closed position (sampling) and closed position (idle). A probe for the measure of soil temperature, soil electrical conductivity, soil volumetric water content, air pressure and air temperature is assembled on the device, which is already arranged for the connection of others external sensors, including an automatic weather station. The automatic station has been tested on the field at Lipari island (Sicily, Italy) during a period of three months, performing CO2 flux measurement (and also weather parameters), each 1 hour. The possibility to measure in semi-continuous mode, and at the same time, the gas fluxes from soil and many external parameters, helps the time series analysis aimed to the identification of gas flux anomalies due to variations in deep system (e.g. onset of volcanic crises) from those triggered by external conditions.

  3. Continuous monitoring methods for assessment of structural integrity in nuclear power plants; Jatkuvan monitoroinnin menetelmaet rakenteiden eheyden varmistamiseen ydinvoimaloissa

    Energy Technology Data Exchange (ETDEWEB)

    Sarkimo, M.

    1998-01-01

    This report is a review of the frequently used continuous monitoring methods that are applied or can possibly be applied in nuclear power plants. The methods covered include condition monitoring and non-destructive testing (NDT) techniques that can be used to detect flaws in components and the malfunction of machinery. The specific techniques for water chemistry monitoring are not covered by this report. The systems based on acoustic emission are considered to be suitable for continuous monitoring applications and these are discussed in greater detail compared to other methods. The loose parts monitoring and leak detection systems based on acoustic emission have practical applications in several nuclear power plants. The real-time monitoring of crack-tip movement using the ultrasonic method is also discussed. Some results are also referred to from the research and development work to monitor crack initiation and growth on the surface of high-speed rotating components using the electromagnetic method. Vibration measurements and analysis are mentioned as a usual tool for monitoring the condition of rotating machinery but also some special aspects of nuclear power plants are included. Finally the on-line fatigue and integrity monitoring systems are briefly discussed and given some considerations regarding the material property measurements using continuous non-destructive methods. (orig.). 34 refs.

  4. Continuous monitoring methods for assessment of structural integrity in nuclear power plants; Jatkuvan monitoroinnin menetelmaet rakenteiden eheyden varmistamiseen ydinvoimaloissa

    Energy Technology Data Exchange (ETDEWEB)

    Sarkimo, M.

    1998-01-01

    This report is a review of the frequently used continuous monitoring methods that are applied or can possibly be applied in nuclear power plants. The methods covered include condition monitoring and non-destructive testing (NDT) techniques that can be used to detect flaws in components and the malfunction of machinery. The specific techniques for water chemistry monitoring are not covered by this report. The systems based on acoustic emission are considered to be suitable for continuous monitoring applications and these are discussed in greater detail compared to other methods. The loose parts monitoring and leak detection systems based on acoustic emission have practical applications in several nuclear power plants. The real-time monitoring of crack-tip movement using the ultrasonic method is also discussed. Some results are also referred to from the research and development work to monitor crack initiation and growth on the surface of high-speed rotating components using the electromagnetic method. Vibration measurements and analysis are mentioned as a usual tool for monitoring the condition of rotating machinery but also some special aspects of nuclear power plants are included. Finally the on-line fatigue and integrity monitoring systems are briefly discussed and given some considerations regarding the material property measurements using continuous non-destructive methods. (orig.). 34 refs.

  5. [The peripheral perfusion pressure: a new non-invasive parameter for the circulatory monitoring of patients (author's transl)].

    Science.gov (United States)

    Huch, A; Lübbers, D W; Huch, R

    1975-01-01

    Heating of a skin area to a temperature of 42 degrees to 44 degrees C produces a certain physiological condition which induces maximal vasodilatation. Detailed experiments have shown that local peripheral vascular resistance of such an area remains constant for several hours. The flow in this area is proportional to the actual perfusion pressure. Relative flow was measured by means of a new type of electrode fixed to the skin like and ECG electrode, and compared with simultaneous intra-arterial blood pressure measruements. The changes in arterial blood pressure were also recorded by the skin electrode. This new parameter is defined as "peripheral perfusion pressure". It is appropiate for non-invasive continuous monitoring of the circulatory system of patients.

  6. Use of microneedle array devices for continuous glucose monitoring: a review.

    Science.gov (United States)

    El-Laboudi, Ahmed; Oliver, Nick S; Cass, Anthony; Johnston, Desmond

    2013-01-01

    Microneedle array devices provide the opportunity to overcome the barrier characteristics of the outermost skin layer, the stratum corneum. This novel technology can be used as a therapeutic tool for transdermal drug delivery, including insulin, or as a diagnostic tool providing access to dermal biofluids, with subsequent analysis of its contents. Over the last decade, the use of microneedle array technology has been the focus of extensive research in the field of transdermal drug delivery. More recently, the diagnostic applications of microneedle technology have been developed. This review summarizes the existing evidence for the use of microneedle array technology as biosensors for continuous monitoring of the glucose content of interstitial fluid, focusing also on mechanics of insertion, microchannel characteristics, and safety profile.

  7. Continuous optical monitoring during the prompt emission of GRB 060111B

    CERN Document Server

    Klotz, A; Stratta, G; Atteia, J L; Boër, M; Malacrino, F; Damerdji, Y; Behrend, R; Klotz, Alain; Gendre, Bruce; Stratta, Giulia; Atteia, Jean-Luc; Boer, Michel; Malacrino, Frederic; Damerdji, Yassine; Behrend, Raoul

    2006-01-01

    We present the time-resolved optical emission of GRB 060111B during its prompt phase, measured with the TAROT robotic observatory. This is the first time that the optical emission from a gamma-ray burst has been continuously monitored with a temporal resolution of a few seconds during the prompt gamma-ray phase. The temporal evolution of the prompt optical emission at the level of several seconds is used to provide a clue to the origin of this emission. The optical emission was found to decay steadily from our first measure, 28s after the trigger, in contrast to the gamma-ray emission, which exhibits strong variability at the same time. This behaviour strongly suggests that the optical emission is due to the reverse shock.

  8. Continuous glucose monitoring for suspected dumping syndrome in infants after Nissen fundoplication.

    Science.gov (United States)

    Ueda, Kazutoshi; Mizumoto, Hiroshi; Shibata, Hirofumi; Miyauchi, Yuya; Sato, Masahito; Hata, Daisuke

    2013-12-01

    Dumping syndrome is infrequently reported, but known to occur after Nissen fundoplication in children. However, it may be difficult both to diagnose and manage. Here we presented four infants who received Nissen fundoplication for severe gastroesophageal reflux disease, two of whom developed dumping syndrome whilst the other two did not. Continuous glucose monitoring (CGM) was very useful to clearly detect large glycemic fluctuation around each feeding. CGM was also helpful to prove the effect of treatment to avoid abnormal glucose levels. We believe that dumping syndrome in children may be underdiagnosed if clinicians rely solely on the recognition of symptoms or limited frequency of blood samplings. CGM might be the most sensitive diagnostic tool.

  9. Effect of continuous glucose monitoring accuracy on clinicians' retrospective decision making in diabetes

    DEFF Research Database (Denmark)

    Mahmoudi, Zeinab; Johansen, Mette Dencker; Nørgaard, Hanne Holdflod;

    2015-01-01

    BACKGROUND: The use of continuous glucose monitoring (CGM) in clinical decision making in diabetes could be limited by the inaccuracy of CGM data when compared to plasma glucose measurements. The aim of the present study is to investigate the impact of CGM numerical accuracy on the precision...... of the interclinician agreement and the intraclinician reproducibility of the decisions. The Cohen's kappa coefficient was used to assess the precision of the decisions. The study was based on retrospective and blind CGM data. RESULTS: For the interclinician agreement, in the first occasion, the kappa of algorithm 1...... was .32, and that of algorithm 2 was .36. For the interclinician agreement, in the second occasion, the kappas of algorithms 1 and 2 were .17 and .22, respectively. For the intraclinician reproducibility of the decisions, the kappas of algorithm 1 were .35, .22, and .80 and the kappas of algorithm 2 were...

  10. Fault and meal detection by redundant continuous glucose monitors and the unscented Kalman filter

    DEFF Research Database (Denmark)

    Mahmoudi, Zeinab; Nørgaard, Kirsten; Poulsen, Niels Kjølstad

    2017-01-01

    The purpose of this study is to develop a method for detecting and compensating the anomalies of continuous glucose monitoring (CGM) sensors as well as detecting unannounced meals. Both features, sensor fault detection/correction and meal detection, are necessary to have a reliable artificial...... is in terms of a patient simulation model, where the model in the detector is the same as the patient simulation model used for evaluation of the detector. The detection module consists of two CGM sensors, two fault detectors, a fault isolator, and an adaptive unscented Kalman filter (UKF). Two types...... of sensor faults, i.e., drift and pressure induced sensor attenuation (PISA), are simulated by a Gaussian random walk model. Each of the fault detectors has a local UKF that receives the signal from the associated sensor, detects faults, and finally tunes the adaptive UKF. A fault isolator that accepts data...

  11. Novel textile systems for the continuous monitoring of vital signals: design and characterization.

    Science.gov (United States)

    Trindade, Isabel G; Martins, Frederico; Dias, Rúben; Oliveira, Cristina; Machado da Silva, José

    2015-08-01

    In this article we present a smart textile system for the continuous monitoring of cardiorespiratory signals, produced and integrated with an industrial embroidery unit. The design of a T-shirt system, having embedded textile sensors and interconnects and custom designed circuit for data collection and Bluetooth transmission is presented. The performance of skin-contact textile electrodes, having distinctive electrical characteristics and surface morphologies, was characterized by measurements of signal to noise ratio, under dry and moisture conditions. The influence of the electrodes size and the wear resistance were addressed. Results of an electrocardiogram acquisition with a subject wearing the T-shirt and display on a smartphone are also shown. The presented smart textile systems exhibit good performance and versatility for custom demand production.

  12. The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors

    Energy Technology Data Exchange (ETDEWEB)

    Bartlett, W.T.; Walker, B.A. [Environmental Evaluation Group, Albuquerque, NM (United States)

    1997-08-01

    Waste Isolation Pilot Plant (WIPP) alpha continuous air monitor (CAM) performance was evaluated to determine if CAMs could detect accidental releases of transuranic radioactivity from the underground repository. Anomalous alpha spectra and poor background subtraction were observed and attributed to salt deposits on the CAM sampling filters. Microscopic examination of salt laden sampling filters revealed that aerosol particles were forming dendritic structures on the surface of the sampling filters. Alpha CAM detection efficiency decreased exponentially as salt deposits increased on the sampling filters, suggesting that sampling-filter salt was performing like a fibrous filter rather than a membrane filter. Aerosol particles appeared to penetrate the sampling-filter salt deposits and alpha particle energy was reduced. These findings indicate that alpha CAMs may not be able to detect acute releases of radioactivity, and consequently CAMs are not used as part of the WIPP dynamic confinement system. 12 refs., 12 figs., 1 tab.

  13. Continuous Glucose Monitoring for Evaluation of Glycemic Excursions after Gastric Bypass

    Directory of Open Access Journals (Sweden)

    Florencia Halperin

    2011-01-01

    Full Text Available Background. Hyperinsulinemic hypoglycemia with neuroglycopenia is a rare complication of Roux-en-Y gastric bypass (RYGB. We hypothesized that continuous glucose monitoring (CGM would be useful to characterize glycemic variability after RYGB. Methods. CGM and mixed meal tolerance testing (MMTT were performed on sixteen post-RYGB subjects, ten with a history of neuroglycopenia on medical treatment and six asymptomatic controls. Results. 9 of 10 subjects with neuroglycopenia developed hypoglycemia defined by glucose <70 mg/dL on CGM, and 3 of 9 on MMTT. In asymptomatic subjects, 3 of 6 had asymptomatic hypoglycemia during CGM, and 3 of 5 on MMTT. Therefore, the sensitivity and specificity to detect clinically significant hypoglycemia was 90% and 50% for CGM and 33% and 40% for MMTT.Conclusions. Asymptomatic hypoglycemia after RYGB is more frequent than commonly recognized. For clinicians evaluating patients for postbypass neuroglycopenia, CGM may be a valuable diagnostic tool.

  14. The influence of the pressure force control signal on selected parameters of the vehicle continuously variable transmission

    Science.gov (United States)

    Bieniek, A.; Graba, M.; Prażnowski, K.

    2016-09-01

    The paper presents results of research on the effect of frequency control signal on the course selected operating parameters of the continuously variable transmission CVT. The study used a gear Fuji Hyper M6 with electro-hydraulic control system and proprietary software for control and data acquisition developed in LabView environment.

  15. Drug choice and therapeutic drug monitoring in the management of canine primary epilepsy : continuing education

    Directory of Open Access Journals (Sweden)

    T. Vaughan

    1999-07-01

    Full Text Available Therapeutic drug monitoring is an underutilised resource in the management of canine primary epilepsy. Many of the anti-epileptic drugs, including phenobarbitone, have variable pharmacokinetic profiles in different dogs, with each individual animal showing variable rates of absorption, distribution, metabolism and excretion. This results in variable serumdrug concentrations with the same oral dose. Many clinicians interpret this situation as therapeutic failure and classify these patients as refractory to treatment. By measuring blood concentrations of drugs at appropriate times, it is possible to explain the efficacy or failure of treatment, and also to prevent serum concentrations from reaching toxic levels. By analysing paired samples, key pharmacokinetic parameters may be calculated for each patient and a profile for the disposition of the drug obtained. Individual optimal drug dosage can be calculated for each patient at little cost to the pet owner.

  16. In-vivo continuous monitoring of mixed venous oxygen saturation by photoacoustic transesophageal echocardiography (Conference Presentation)

    Science.gov (United States)

    Li, Li; Subramaniam, Balachundhar; Aguirre, Aaron D.; Andrawes, Michael N.; Tearney, Guillermo J.

    2016-02-01

    Mixed venous oxygen saturation (SvO2), measured from pulmonary arteries, is a gold-standard measure of the dynamic balance between the oxygen supply and demand in the body. In critical care, continuous monitoring of SvO2 plays a vital role in early detection of circulatory shock and guiding goal-oriented resuscitation. In current clinical practice, SvO2 is measured by invasive pulmonary artery catheters (PAC), which are associated with a 10% risk of severe complications. To address the unmet clinical need for a non-invasive SvO2 monitor, we are developing a new technology termed photoacoustic transesophageal echocardiography (PA-TEE). PA-TEE integrates transesophageal echocardiography with photoacoustic oximetry, and enables continuous assessment of SvO2 through an esophageal probe that can be inserted into the body in a minimally invasive manner. We have constructed a clinically translatable PA-TEE prototype, which features a mobile OPO laser, a modified ultrasonography console and a dual-modality esophageal probe. Comprised of a rotatable acoustic array detector, a flexible optical fiber bundle and a light-integrating acoustic lens, the oximetric probe has an outer diameter smaller than 15 mm and will be tolerable for most patients. Through custom-made C++/Qt software, our device acquires and displays ultrasonic and photoacoustic images in real time to guide the deployment of the probe. SvO2 is calculated on-line and updated every second. PA-TEE has now been used to evaluate SvO2 in living swine. Our findings show that changing the fraction of oxygen in the inspired gas modulates SvO2 measured by PA-TEE. Statistic comparison between SvO2 measurements from PA-TEE in vivo the gold-standard laboratorial analysis on blood samples drawn from PACs will be presented.

  17. Continuation of long-term global SO2 pollution monitoring from OMI to OMPS

    Science.gov (United States)

    Zhang, Yan; Li, Can; Krotkov, Nickolay A.; Joiner, Joanna; Fioletov, Vitali; McLinden, Chris

    2017-04-01

    Over the past 20 years, advances in satellite remote sensing of pollution-relevant species have made space-borne observations an increasingly important part of atmospheric chemistry research and air quality management. This progress has been facilitated by advanced UV-vis spectrometers, such as the Ozone Monitoring Instrument (OMI) on board the NASA Earth Observing System (EOS) Aura satellite, and continues with new instruments, such as the Ozone Mapping and Profiler Suite (OMPS) on board the NASA-NOAA Suomi National Polar-orbiting Partnership (SNPP) satellite. In this study, we demonstrate that it is possible, using our state-of-the-art principal component analysis (PCA) retrieval technique, to continue the long-term global SO2 pollution monitoring started by OMI with the current and future OMPS instruments that will fly on the NOAA Joint Polar Satellite System (JPSS) 1, 2, 3, and 4 satellites in addition to SNPP, with a very good consistency of retrievals from these instruments. Since OMI SO2 data have been primarily used for (1) providing regional context on air pollution and long-range transport on a daily basis and (2) providing information on point emission sources on an annual basis after data averaging, we focused on these two aspects in our OMI-OMPS comparisons. Four years of retrievals (2012-2015) have been compared for three regions: eastern China, Mexico, and South Africa. In general, the comparisons show relatively high correlations (r = 0. 79-0.96) of daily regional averaged SO2 mass between the two instruments and near-unity regression slopes (0.76-0.97). The annual averaged SO2 loading differences between OMI and OMPS are small (worth noting that consistent SO2 retrievals were achieved without any explicit adjustments to OMI or OMPS radiance data and that the retrieval agreement may be further improved by introducing a more comprehensive Jacobian lookup table than is currently used.

  18. BION-M 1: First continuous blood pressure monitoring in mice during a 30-day spaceflight

    Science.gov (United States)

    Andreev-Andrievskiy, Alexander; Popova, Anfisa; Lloret, Jean-Christophe; Aubry, Patrick; Borovik, Anatoliy; Tsvirkun, Daria; Vinogradova, Olga; Ilyin, Eugeniy; Gauquelin-Koch, Guillemette; Gharib, Claude; Custaud, Marc-Antoine

    2017-05-01

    Animals are an essential component of space exploration and have been used to demonstrate that weightlessness does not disrupt essential physiological functions. They can also contribute to space research as models of weightlessness-induced changes in humans. Animal research was an integral component of the 30-day automated Russian biosatellite Bion-M 1 space mission. The aim of the hemodynamic experiment was to estimate cardiovascular function in mice, a species roughly 3000 times smaller than humans, during prolonged spaceflight and post-flight recovery, particularly, to investigate if mice display signs of cardiovascular deconditioning. For the first time, heart rate (HR) and blood pressure (BP) were continuously monitored using implantable telemetry during spaceflight and recovery. Decreased HR and unchanged BP were observed during launch, whereas both HR and BP dropped dramatically during descent. During spaceflight, BP did not change from pre-flight values. However, HR increased, particularly during periods of activity. HR remained elevated after spaceflight and was accompanied by increased levels of exercise-induced tachycardia. Loss of three of the five mice during the flight as a result of the hardware malfunction (unrelated to the telemetry system) and thus the limited sample number constitute the major limitation of the study. For the first time BP and HR were continuously monitored in mice during the 30-day spaceflight and 7-days of post-flight recovery. Cardiovascular deconditioning in these tiny quadruped mammals was reminiscent of that in humans. Therefore, the loss of hydrostatic pressure in space, which is thought to be the initiating event for human cardiovascular adaptation in microgravity, might be of less importance than other physiological mechanisms. Further experiments with larger number of mice are needed to confirm these findings.

  19. Continuous broadband seismic observation on the Greenland Ice Sheet under Greenland Ice Sheet monitoring Network

    Science.gov (United States)

    Tsuboi, Seiji; Kanao, Masaki; Tono, Yoko; Himeno, Tetsuto; Toyokuni, Genti; Childs, Dean; Dahl-Jensen, Trine; anderson, Kent

    2013-04-01

    We have installed the ice sheet broadband seismograph station, called ICE-S (DK.ICESG) in June 2011, in collaboration with IRIS Polar Services under the GreenLand Ice Sheet monitoring Network (GLISN), which is a new, international, broadband seismic capability for Greenland being implemented through the collaboration between Denmark, Canada, France, Germany, Italy, Japan, Norway, Poland, Switzerland, and the USA. The primary purpose of GLISN project is to define the fine structure and detailed mechanisms of glacial earthquakes within the Greenland Ice Sheet. These glacial earthquakes in the magnitude range 4.6-5.1 may be modeled as a large glacial ice mass sliding downhill several meters on its basal surface over duration of 30 to 60 seconds. Glacial earthquakes have been observed at seismic stations within Greenland (Larsen et al, 2006), but the coverage was very sparse and a broadband, real-time seismic network was needed to be installed throughout Greenland's Ice Sheet and perimeter. The National Institute for Polar Research and Japan Agency for Marine-Earth Science and Technology are members of GLISN project and we have started to operate ICESG station since 2011. The station is equipped with a CMG-3T broadband seismometer and a Quanterra Q330 data logger. We have visited the station again in May, 2012 and successfully retrieved one year of continuous records from the broadband seismometer and updated the telemetry system to eventually allow real time monitoring of the station. ICESG station is now daily sending 1 Hz continuous data over the iridium satellite system using RUDICS. The observed three component seismograms demonstrate that the quality of this ice sheet station is good enough to record not only local earthquakes around Greeland but also teleseismic earthquakes. We could record three component broadband seismograms for April 11, 2012 Off the west coast of Northern Sumatra earthquake (Mw8.6). These seismograms show high signal to noise ratio

  20. The TOMPs ambient air monitoring network - Continuous data on UK air quality for over 20 years.

    Science.gov (United States)

    Graf, Carola; Katsoyiannis, Athanasios; Jones, Kevin C; Sweetman, Andrew J

    2016-10-01

    Long-term air monitoring datasets are needed for persistent organic pollutants (POPs) to assess the effectiveness of source abatement measures and the factors controlling ambient levels. The Toxic Organic Micro Pollutants (TOMPs) Network, which has operated since 1991, collects ambient air samples at six sites across England and Scotland, using high-volume active air samplers. The network provides long-term ambient air trend data for a range of POPs at both urban and rural locations. Data from the network provides the UK Government, regulators and researchers with valuable information on emission/source controls and on the effectiveness of international chemicals regulation such as the Stockholm Convention and UN/ECE Protocol on POPs. The target chemicals of TOMPs have been polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs), polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and, since 2010, polybrominated diphenyl ethers (PBDEs). The continuous monitoring of these compounds demonstrates the constant decline in UK air concentrations over the last two decades, with average clearance rates for PCDD/Fs in urban locations of 5.1 years and for PCBs across all sites 6.6 years. No significant declines in rural locations for PCDD/Fs have been observed. There is a strong observable link between the declining ambient air concentrations and the emission reductions estimated in the annually produced National Atmospheric Emission Inventory (NAEI) dataset. These findings clearly demonstrate the unique strengths of long-term consistent datasets for the evaluation of the success of chemical regulation and control.

  1. Continuing EVN monitoring of HST-1 in the jet of M87

    CERN Document Server

    Hada, Kazuhiro; Giovannini, Gabriele; Casadio, Carolina; Beilicke, Matthias; Cesarini, Andrea; Cheung, Teddy; Doi, Akihiro; Gómez, José Luis; Krawczynski, Henric; Kino, Motoki; Nagai, Hiroshi

    2015-01-01

    The relativistic jet in M87 offers a unique opportunity for understanding the detailed jet structure and emission processes due to its proximity. In particular, the peculiar jet region HST-1 at ~1 arcsecond (or 80 pc, projected) from the nucleus has attracted a great deal of interest in the last decade because of its superluminal motion and broadband radio-to-X-ray outbursts, which may be further connected to the gamma-ray productions up to TeV energies. Over the last five years, we have been doing an intensive monitoring of HST-1 with EVN at 5GHz in order to examine the detailed structural evolution and its possible connection to high-energy activities. While this program already yielded interesting results in terms of the detailed mas-scale structure, proper motion measurements and structural variations, the recent HST-1 brightness is continuously decreasing at this frequency. To counter this, we have shifted our monitoring frequency to 1.7GHz from October 2013. This strategy successfully recovered the fain...

  2. The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors

    Energy Technology Data Exchange (ETDEWEB)

    Bartlett, W.T.; Walker, B.A.

    1996-01-01

    Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This report shows that sampling-filter salt deposits directly affect radon-thoron daughter alpha spectra and overall monitor efficiency. Previously it was assumed that aerosol was mechanically collected on the surface of CAM sampling filters, but this review suggests that electrostatic and other particle collection mechanisms are more important than previously thought. The mechanism of sampling-filter particle collection is critical to measurement of acute releases of radioactivity. 41 refs.

  3. Acoustic monitoring on a humpback whale (Megaptera novaeangliae) feeding ground shows continual singing into late Spring.

    Science.gov (United States)

    Clark, Christopher W; Clapham, Phillip J

    2004-05-22

    Singing by males is a major feature of the mating system of humpback whales, Megaptera novaeangliae (Borowski). Although a few songs have been opportunistically recorded on the whales' high-latitude feeding grounds, singing in these regions was thought to be only sporadic. We report results from the first continuous acoustic monitoring of a humpback whale feeding ground (off Cape Cod, MA, USA) in spring. Using autonomous sea-floor recording systems, we found singing on a daily basis over the entire 25 day monitoring period, from 14 May to 7 June 2000. For much of the period, song was recorded 24 h per day. These results, combined with evidence for aseasonal conceptions in whaling catch data, suggest that the humpback whale breeding season should no longer be considered as confined to lower-latitude regions in winter. Rather, we suggest breeding extends geographically and temporally onto feeding grounds into at least spring and early summer. Singing at these times represents either low-cost opportunistic advertising by (perhaps relatively few) males to court females that failed to conceive during the winter, and/or possibly an intrasexual display.

  4. Surface air concentration and deposition of lead-210 in French Guiana: two years of continuous monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Melieres, Marie-Antoinette E-mail: melieres@glaciog.ujf-grenoble.fr; Pourchet, Michel; Richard, Sandrine

    2003-07-01

    To make up for the lack of data on {sup 210}Pb aerosol deposition in tropical regions and to use this radionuclide as an aerosol tracer,a monitoring station was run for two years at Petit-Saut, French Guiana. Lead-210 concentration in air at ground level was monitored continuously together with atmospheric total deposition. The air concentration has a mean value of 0.23{+-}0.02 mBq m{sup -3} during both wet and dry seasons, and it is only weakly affected by the precipitation mechanism. This result was unexpected in a wet tropical region, with a high precipitation rate. In contrast, deposition clearly correlates with precipitation for low/moderate rainfall (<15 cm per 15-day), while this correlation is masked by strong fluctuations at high rainfall. The estimated mean annual deposition over the last ten years is 163{+-}75 Bq m{sup -2} y{sup -1}. This provides a procedure fo estimating this mean flux at other sites in French Guiana.

  5. Using Continuous Glucose Monitoring Data and Detrended Fluctuation Analysis to Determine Patient Condition

    Science.gov (United States)

    Thomas, Felicity; Signal, Matthew; Chase, J. Geoffrey

    2015-01-01

    Patients admitted to critical care often experience dysglycemia and high levels of insulin resistance, various intensive insulin therapy protocols and methods have attempted to safely normalize blood glucose (BG) levels. Continuous glucose monitoring (CGM) devices allow glycemic dynamics to be captured much more frequently (every 2-5 minutes) than traditional measures of blood glucose and have begun to be used in critical care patients and neonates to help monitor dysglycemia. In an attempt to obtain a better insight relating biomedical signals and patient status, some researchers have turned toward advanced time series analysis methods. In particular, Detrended Fluctuation Analysis (DFA) has been a topic of many recent studies in to glycemic dynamics. DFA investigates the “complexity” of a signal, how one point in time changes relative to its neighboring points, and DFA has been applied to signals like the inter-beat-interval of human heartbeat to differentiate healthy and pathological conditions. Analyzing the glucose metabolic system with such signal processing tools as DFA has been enabled by the emergence of high quality CGM devices. However, there are several inconsistencies within the published work applying DFA to CGM signals. Therefore, this article presents a review and a “how-to” tutorial of DFA, and in particular its application to CGM signals to ensure the methods used to determine complexity are used correctly and so that any relationship between complexity and patient outcome is robust. PMID:26134835

  6. Near-continuous thermal monitoring of a diverse tropical forest canopy

    Science.gov (United States)

    Pau, S.; Still, C. J.; Kim, Y.; Detto, M.

    2015-12-01

    Tropical species may be highly sensitive to temperature increases associated with climate change because of their narrow thermal tolerances. Recent work has highlighted the importance of temperature in tropical forest function, however most studies use air temperature measurements from sparse meteorological stations even though surface temperatures are known to deviate from air temperatures. Tropical organisms exist in microclimates that are highly variable in space and time and not easily measured in natural environments. This is in part because of the complex structure of tropical forests and the potential for organisms themselves to modify their own environment. In the case of plants, leaf temperature is linked to the water and surface energy balance of their microenvironment. Here we present results from near-continuous thermal camera monitoring of the forest canopy in Barro Colorado Island, Panama (5-minute intervals for approximately 9 months). We compare daytime (maximum) vs. nighttime (minimum) differences between canopy temperature and air temperature, relative humidity, solar radiation, and precipitation. On average, canopy temperatures are consistently ~2 degrees Celsius higher than air temperatures. These data can paired with flux tower data on-site and used to advance understanding of temperature controls on the structure and function of tropical forests, such as carbon assimilation, phenology, and habitat monitoring, and can be integrated into models to improve predictions of tropical forest response to future climate change.

  7. The use of VEPs for CNS monitoring during continuous cardiopulmonary bypass and circulatory arrest.

    Science.gov (United States)

    Keenan, N K; Taylor, M J; Coles, J G; Prieur, B J; Burrows, F A

    1987-07-01

    Cerebral function was monitored with the use of visual evoked potentials (VEPs) in 16 infants (mean age 9.9 +/- 4.3 months) during surgery for congenital cardiac anomalies. While hypothermia was employed in all patients, half (8) remained on continuous cardiopulmonary bypass (CCB) while the rest were cooled to lower temperatures before the induction of circulatory stasis and venous exsanguination (CA), i.e., profound hypothermic circulatory arrest (PHCA). VEPs were recorded before, during and after surgical intervention. Latency changes occurred in both the N100 and P145 components of the VEP as a function of systemic temperature during cooling in both groups. Differences in the VEPs were found between the two groups post-operatively, with the most interesting result being a greater increase in P145 latency in the CA group after rewarming. To the extent that VEPs reflect neurological status, our findings suggested that CCB was associated with less perturbation in acute neurological status than PHCA, and shorter arrest times and lower temperatures during CA were associated with the most favourable post-operative VEPs. Hence, intraoperative monitoring of VEPs appeared to be useful as an objective measure of the short-term effects of various cardiopulmonary procedures on neurophysiological function.

  8. Continuous ventricular cerebrospinal fluid drainage with intracranial pressure monitoring for management of posttraumatic diffuse brain swelling

    Directory of Open Access Journals (Sweden)

    Almir Ferreira de Andrade

    2011-02-01

    Full Text Available BACKGROUND: Ventricular drainage has played an important role in the management of traumatic brain-injured patients. The aim of the present study was describe outcomes in a series of 57 patients with diffuse brain swelling underwent to intracranial pressure (ICP monitoring. METHOD: Fifty-eight patients with diffuse posttraumatic brain swelling, were evaluated prospectively. The Glasgow Coma Scale (GCS scores of patients varied from 4 to 12. Patients groups divided according to GCS and age. Patient neurological assessment was classified as favorable, unfavorable, and death. RESULTS: Mechanisms of injury were vehicle accidents in 72.4% and falls in 15.6%. 54% of patients had GCS scores between 6 and 8. There were no statistical differences, regarding outcome, between groups separated by age. In the adults group (n=47, 44.7% evolved favorably. CONCLUSION: Our results indicate a poor prognosis in patients with brain swelling. We believe that continuous ventricular CSF drainage with ICP monitoring is a simple method as an adjunct in the management of these patients.

  9. Predicted responses for a particulate detection system in a continuous stack monitor.

    Science.gov (United States)

    Tries, Mark A; Holloman, Ryan L; Bobe, Leo M

    2002-10-01

    Predicted counting rate responses were developed for a particulate detection system that is used for continuous monitoring for the presence of radioactive particulates in the effluent air from a research reactor. The particulate detection system consists of a moving filter paper assembly, a plastic scintillation detector, and a rate meter output, and is part of a comprehensive stack monitoring system. A predicted response was derived for the case of a steady-state activity distribution across the surface of the moving filter paper that is in proximity to the detector and was determined to be 1.59 x 10(7) cpm per unit airborne concentration of 138Cs (expressed in units of Bq cm(-3)), where 138Cs was used as an indicator for a hypothetical fission product release. The corresponding response model provided by the manufacturer was found to underestimate airborne activity concentrations by about an order of magnitude. A predicted response also was derived for the case of a rapid change in airborne activity concentration, which was formulated based on the kinetics of the rate meter circuit and was used to establish alarm settings and detection limits for the particulate detection system.

  10. Spectral fluorescence signature techniques and absorption measurements for continuous monitoring of biofuel-producing microalgae cultures

    Science.gov (United States)

    Martín de la Cruz, M. C.; Gonzalez Vilas, L.; Yarovenko, N.; Spyrakos, E.; Torres Palenzuela, J. M.

    2013-08-01

    Biofuel production from microalgae can be both sustainable and economically viable. Particularly in the case of algal growth in wastewater an extra benefit is the removal or biotransformation of pollutants from these types of waters. A continuous monitoring system of the microalgae status and the concentration of different wastewater contaminants could be of great help in the biomass production and the water characterisation. In this study we present a system where spectral fluorescence signature (SFS) techniques are used along with absorption measurements to monitor microalgae cultures in wastewater and other mediums. This system aims to optimise the microalgae production for biofuel applications or other uses and was developed and tested in prototype indoor photo-bioreactors at the University of Vigo. SFS techniques were applied using the fluorescence analyser INSTAND-SCREENER developed by Laser Diagnostic Instruments AS. INSTAND-SCREENER permits wavelength scanning in two modes, one in UV and another in VIS. In parallel, it permits the on-line monitoring and rapid analysis of both water quality and phytoplankton status without prior treatment of the sample. Considering that different contaminants and microalgae features (density, status etc.) have different spectral signatures of fluorescence and absorption properties, it is possible to characterise them developing classification libraries. Several algorithms were used for the classification. The implementation of this system in an outdoor raceway reactor in a Spanish wastewater treatment plant is also discussed. This study was part of the Project EnerBioAlgae (http://www.enerbioalgae.com/), which was funded by the Interreg SUDOE and led by the University of Vigo.

  11. A label-free fiber-optic Turbidity Affinity Sensor (TAS) for continuous glucose monitoring.

    Science.gov (United States)

    Dutt-Ballerstadt, Ralph; Evans, Colton; Pillai, Arun P; Gowda, Ashok

    2014-11-15

    In this paper, we describe the concept of a novel implantable fiber-optic Turbidity Affinity Sensor (TAS) and report on the findings of its in-vitro performance for continuous glucose monitoring. The sensing mechanism of the TAS is based on glucose-specific changes in light scattering (turbidity) of a hydrogel suspension consisting of small particles made of crosslinked dextran (Sephadex G100), and a glucose- and mannose-specific binding protein - Concanavalin A (ConA). The binding of ConA to Sephadex particles results in a significant turbidity increase that is much greater than the turbidity contribution by the individual components. The turbidity of the TAS was measured by determining the intensity of light passing through the suspension enclosed within a small semi-permeable hollow fiber (OD: 220 μm, membrane thickness: 20 μm, molecular weight cut-off: 10 kDa) using fiber optics. The intensity of measured light of the TAS was proportional to the glucose concentration over the concentration range from 50mg/dL to 400mg/dL in PBS and whole blood at 37°C (R>0.96). The response time was approximately 4 min. The stability of the glucose response of the TAS decreased only slightly (by 20%) over an 8-day study period at 37°C. In conclusion, this study demonstrated proof-of-concept of the TAS for interstitial glucose monitoring. Due to the large signal amplitude of the turbidity change, and the lack of need for wavelength-specific emission and excitation filters, a very small, robust and compact TAS device with an extremely short optical pathlength could be feasibly designed and implemented for in-vivo glucose monitoring in people with diabetes.

  12. Continuous fatigue crack monitoring of bridges: Long-Term Electrochemical Fatigue Sensor (LTEFS)

    Science.gov (United States)

    Moshier, Monty A.; Nelson, Levi; Brinkerhoff, Ryan; Miceli, Marybeth

    2016-04-01

    Fatigue cracks in steel bridges degrade the load-carrying capacity of these structures. Fatigue damage accumulation caused by the repetitive loading of everyday truck traffic can cause small fatigue cracks initiate. Understanding the growth of these fatigue cracks is critical to the safety and reliability of our transportation infrastructure. However, modeling fatigue in bridges is difficult due to the nature of the loading and variations in connection integrity. When fatigue cracks reach critical lengths failures occur causing partial or full closures, emergency repairs, and even full structural failure. Given the aging US highway and the trend towards asset management and life extension, the need for reliable, cost effective sensors and monitoring technologies to alert bridge owners when fatigue cracks are growing is higher than ever. In this study, an innovative Long-Term Electrochemical Fatigue Sensor (LTEFS) has been developed and introduced to meet the growing NDT marketplace demand for sensors that have the ability to continuously monitor fatigue cracks. The performance of the LTEFS has been studied in the laboratory and in the field. Data was collected using machined specimens with different lengths of naturally initiated fatigue cracks, applied stress levels, applied stress ratios, and for both sinusoidal and real-life bridge spectrum type loading. The laboratory data was evaluated and used to develop an empirically based algorithm used for crack detection. Additionally, beta-tests on a real bridge structure has been completed. These studies have conclusively demonstrated that LTEFS holds great potential for long-term monitoring of fatigue cracks in steel structures

  13. APPLICATION OF PARAMETER CONTINUATION METHOD FOR INVESTIGATION OF VIBROIMPACT SYSTEMS DYNAMIC BEHAVIOUR. PROBLEM STATE. SHORT SURVEY OF WORLD SCIENTIFIC LITERATURE

    Directory of Open Access Journals (Sweden)

    V.A. Bazhenov

    2014-12-01

    Full Text Available Authors in their works study vibroimpact system dynamic behaviour by numerical parametric continuation technique combined with shooting and Newton-Raphson’s methods. The technique is adapted to two-mass two-degree-of-freedom vibroimpact system under periodic excitation. Impact is simulated by nonlinear contact interaction force based on Hertz’s contact theory. Stability or instability of obtained periodic solutions is determined by monodromy matrix eigenvalues (multipliers based on Floquet’s theory. In the present paper we describe the state of problem of parameter continuation method using for nonlinear tasks solution. Also we give the short survey of numerous contemporary literature in English and Russian about parameter continuation method application for nonlinear problems. This method is applied for vibroimpact problem solving more rarely because of the difficulties connected with repeated impacts.

  14. Remote monitoring of implantable devices: Should we continue to ignore it?

    Science.gov (United States)

    Bertini, Matteo; Marcantoni, Lina; Toselli, Tiziano; Ferrari, Roberto

    2016-01-01

    The number of patients with implantable cardioverter defibrillators (ICDs) is increasing. In addition to improve survival, ICD can collect data related to device function and physiological parameters. Remote monitoring (RM) of these data allows early detection of technical or clinical problems and a prompt intervention (reprogramming device or therapy adjustment) before the patient require hospitalization. RM is not a substitute for emergency service and its consultation is now limited during working hours. Thus, a consent form is required to inform patients about benefits and limitations. The available studies indicate that remote monitoring is more effective than traditional calendar face to face based encounters. RM is safe, highly reliable, cost efficient, allows quick reply to failures, and reduces the number of scheduled visits and the incidence of inappropriate shocks with a positive impact on survival. It follows that RM has the credentials to be the standard of care for ICD management; however, unfortunately, there is a delay in physician acceptance and implementation. The recent observations from randomized IN-TIME study that showed a clear survival benefit with RM in heart failure patients have encouraged us to review both the negative and positive aspects of RM collected in a little more than a decade.

  15. Process monitoring and modeling of a continuous pharmaceutical from powder to tablet process Line using a mass & energy balance

    DEFF Research Database (Denmark)

    Beer, Thomas De; Mortier, Séverine Thérèse F.C.; Gernaey, Krist

    2014-01-01

    The intention to shift from batch to continuous production processes within the pharmaceutical industry enhances the need to monitor and control the process in-line and real-time to continuously guarantee the end-product quality. Mass and energy balances have been successfully applied to a drying...

  16. Photoacoustic and photothermal cytometry for monitoring multiple blood rheology parameters in vivo

    Science.gov (United States)

    Galanzha, Ekaterina I.; Zharov, Vladimir P.

    2012-01-01

    Alterations of blood rheology (hemorheology) are important for the early diagnosis, prognosis, and prevention of many diseases, including myocardial infarction, stroke, sickle cell anemia, thromboembolism, trauma, inflammation, and malignancy. However, real-time in vivo monitoring of hemorheological status using multiple parameters over long periods of time has not been reported. Here we describe the capability of label-free photoacoustic (PA) and photothermal (PT) flow cytometry in detection and imaging modes for dynamic monitoring of rheological parameters in circulating blood. We show that this integrated platform can simultaneously measure the main rheological parameters and may improve their diagnostic value. Using phenomenological approaches, we analyze correlations of PT and PA signal characteristics in the dynamic modes with red blood cell (RBC) aggregation, deformability, shape (e.g., as in sickle cells), intracellular hemoglobin distribution, individual cell velocity, flux of RBCs, and likely shear rate. Proof of concept is demonstrated in ex vivo and in vivo tests, including high-speed PT imaging of RBC shape in pathological conditions and identification of sickle cells in a mouse model of human sickle cell disease. These studies revealed the potential of this new platform integrating PT, PA, and conventional optical techniques for translation to use in humans using safe, portable, laser-based medical devices for point-of-care screening of disease progression and therapy efficiency. PMID:21948731

  17. In vivo photoacoustic and photothermal cytometry for monitoring multiple blood rheology parameters.

    Science.gov (United States)

    Galanzha, Ekaterina I; Zharov, Vladimir P

    2011-10-01

    Alterations of blood rheology (hemorheology) are important for the early diagnosis, prognosis, and prevention of many diseases, including myocardial infarction, stroke, sickle cell anemia, thromboembolism, trauma, inflammation, and malignancy. However, real-time in vivo assessment of multiple hemorheological parameters over long periods of time has not been reported. Here, we review the capabilities of label-free photoacoustic (PA) and photothermal (PT) flow cytometry for dynamic monitoring of hemorhelogical parameters in vivo which we refer to as photoacoustic and photothermal blood rheology. Using phenomenological models, we analyze correlations between both PT and PA signal characteristics in the dynamic modes and following determinants of blood rheology: red blood cell (RBC) aggregation, deformability, shape (e.g., as in sickle cells), intracellular hemoglobin distribution, individual cell velocity, hematocrit, and likely shear rate. We present ex vivo and in vivo experimental verifications involving high-speed PT imaging of RBCs, identification of sickle cells in a mouse model of human sickle cell disease and in vivo monitoring of complex hemorheological changes (e.g., RBC deformability, hematocrit and RBC aggregation). The multi-parameter platform that integrates PT, PA, and conventional optical techniques has potential for translation to clinical applications using safe, portable, laser-based medical devices for point-of-care screening of disease progression and therapy efficiency.

  18. Moving to continuous facial expression space using the MPEG-4 facial definition parameter (FDP) set

    Science.gov (United States)

    Karpouzis, Kostas; Tsapatsoulis, Nicolas; Kollias, Stefanos D.

    2000-06-01

    Research in facial expression has concluded that at least six emotions, conveyed by human faces, are universally associated with distinct expressions. Sadness, anger, joy, fear, disgust and surprise are categories of expressions that are recognizable across cultures. In this work we form a relation between the description of the universal expressions and the MPEG-4 Facial Definition Parameter Set (FDP). We also investigate the relation between the movement of basic FDPs and the parameters that describe emotion-related words according to some classical psychological studies. In particular Whissel suggested that emotions are points in a space, which seem to occupy two dimensions: activation and evaluation. We show that some of the MPEG-4 Facial Animation Parameters (FAPs), approximated by the motion of the corresponding FDPs, can be combined by means of a fuzzy rule system to estimate the activation parameter. In this way variations of the six archetypal emotions can be achieved. Moreover, Plutchik concluded that emotion terms are unevenly distributed through the space defined by dimensions like Whissel's; instead they tend to form an approximately circular pattern, called 'emotion wheel,' modeled using an angular measure. The 'emotion wheel' can be defined as a reference for creating intermediate expressions from the universal ones, by interpolating the movement of dominant FDP points between neighboring basic expressions. By exploiting the relation between the movement of the basic FDP point and the activation and angular parameters we can model more emotions than the primary ones and achieve efficient recognition in video sequences.

  19. Continuous monitoring of a mountain snowpack in the Austrian Alps by above-ground neutron sensing

    Science.gov (United States)

    Schattan, Paul; Baroni, Gabriele; Oswald, Sascha E.; Schöber, Johannes; Fey, Christine; Francke, Till; Huttenlau, Matthias; Achleitner, Stefan

    2017-04-01

    In alpine catchments the knowledge of the spatially and temporally heterogeneous dynamics of snow accumulation and depletion is crucial for modelling and managing water resources. While snow covered area can be retrieved operationally from remote sensing data, continuous measurements of other snow state variables like snow depth (SD) or snow water equivalent (SWE) remain challenging. Existing methods of retrieving both variables in alpine terrain face severe issues like a lack of spatial representativeness, labour-intensity or discontinuity in time. Recently, promising new measurement techniques combining a larger support with low maintenance cost like above-ground gamma-ray scintillators, GPS interferometric reflectometry or above-ground cosmic-ray neutron sensors (CRNS) have been suggested. While CRNS has proven its potential for monitoring soil moisture in a wide range of environments and applications, the empirical knowledge of using CRNS for snowpack monitoring is still very limited and restricted to shallow snowpacks with rather uniform evolution. The characteristics of an above-ground cosmic-ray neutron sensor (CRNS) were therefore evaluated for monitoring a mountain snowpack in the Austrian Alps (Kaunertal, Tyrol) during three winter seasons. The measurement campaign included a number of measurements during the period from 03/2014 to 06/2016: (i) neutron count measurements by CRNS, (ii) continuous point-scale SD and SWE measurements from an automatic weather station and (iii) 17 Terrestrial Laser Scanning (TLS) with simultaneous SD and SWE surveys. The highest accumulation in terms of SWE was found in 04/2014 with 600 mm. Neutron counts were compared to all available snow data. While previous studies suggested a signal saturation at around 100 mm of SWE, no complete signal saturation was found. A strong non-linear relation was found for both SD and SWE with best fits for spatially distributed TLS based snow data. Initially slightly different shapes were

  20. Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour.

    Science.gov (United States)

    Alfirevic, Zarko; Devane, Declan; Gyte, Gillian Ml; Cuthbert, Anna

    2017-02-03

    Cardiotocography (CTG) records changes in the fetal heart rate and their temporal relationship to uterine contractions. The aim is to identify babies who may be short of oxygen (hypoxic) to guide additional assessments of fetal wellbeing, or determine if the baby needs to be delivered by caesarean section or instrumental vaginal birth. This is an update of a review previously published in 2013, 2006 and 2001. To evaluate the effectiveness and safety of continuous cardiotocography when used as a method to monitor fetal wellbeing during labour. We searched the Cochrane Pregnancy and Childbirth Group Trials Register (30 November 2016) and reference lists of retrieved studies. Randomised and quasi-randomised controlled trials involving a comparison of continuous cardiotocography (with and without fetal blood sampling) with no fetal monitoring, intermittent auscultation intermittent cardiotocography. Two review authors independently assessed study eligibility, quality and extracted data from included studies. Data were checked for accuracy. We included 13 trials involving over 37,000 women. No new studies were included in this update.One trial (4044 women) compared continuous CTG with intermittent CTG, all other trials compared continuous CTG with intermittent auscultation. No data were found comparing no fetal monitoring with continuous CTG. Overall, methodological quality was mixed. All included studies were at high risk of performance bias, unclear or high risk of detection bias, and unclear risk of reporting bias. Only two trials were assessed at high methodological quality.Compared with intermittent auscultation, continuous cardiotocography showed no significant improvement in overall perinatal death rate (risk ratio (RR) 0.86, 95% confidence interval (CI) 0.59 to 1.23, N = 33,513, 11 trials, low quality evidence), but was associated with halving neonatal seizure rates (RR 0.50, 95% CI 0.31 to 0.80, N = 32,386, 9 trials, moderate quality evidence). There was no

  1. On-line monitoring of the intravascular volume during haemodialysis by continuous refractometry.

    Science.gov (United States)

    Kuhlmann, U; van Buuren, F; Aziz, O; Lange, H

    1999-01-01

    The control of intravascular volume (IVV) by continuous on-line measurement of protein concentration would optimise the patients' specific rate of ultrafiltration. To prove the accuracy of a refractometric device, plasma was continuously drawn by haemofiltration during 10 haemodialysis treatments of male patients. Refractometry reflects highly significant changes in the concentrations of filtrate proteins (r = 0.862, p < 0.001) and blood proteins (rtotal = 0.593, ptotal < 0.001). In vitro, the refractometric device detected a change of protein concentration of 0.041 g/L through a refraction increase of 0.1 mV. The power of discrimination was 0.067% of IVV However, in vivo, the accuracy of IVV refractometric monitoring is reduced by interference factors such as sodium (0. 141 mV/mmol/L), glucose (0.034 mV/mg/dl) and triglycerides (-0.040 mV/mg/dl). Adjustment of the refraction data using sodium and glucose electrodes and plasma filters with a cut-off below the size of chylomicrons is recommended.

  2. Continuous intra-arterial blood pH monitoring in rabbits with acid-base disorders.

    Science.gov (United States)

    Jin, Weizhong; Jiang, Jinjun; Wang, Xun; Zhu, Xiaodan; Wang, Guifang; Song, Yuanlin; Bai, Chunxue

    2011-07-31

    The acid-base balance of arterial blood is important for the clinical management of seriously ill patients, especially patients with acute lung injury or acute respiratory distress syndrome. We developed a novel fluorosensor for continuous blood pH monitoring and evaluated its performance both in vitro and in vivo in rabbits with acid-base disorders. The pH sensor is made of N-allyl-4-piperazinyl-1, 8-napthalimide and 2-hydroxyethyl methacrylate, which were bonded at the distal end of the optical fiber. The fluorescence intensity increased as the pH decreased with good reproducibility, selectivity and linearity in the pH range of 6-8. The pH measurement precision was 0.03 ± 0.03 pH units with a bias of -0.02 ± 0.04 (n = 105) and -0.00 ± 0.05 pH units (n=189) in rabbits with metabolic and respiratory acid-base orders, respectively. The optical pH sensor can accurately measure pH fluctuations with a fast response and is a promising candidate for continuous in-line measurements of blood pH in critical care patients.

  3. Towards continuous and real-time attention monitoring at work: reaction time versus brain response.

    Science.gov (United States)

    Mijović, Pavle; Ković, Vanja; De Vos, Maarten; Mačužić, Ivan; Todorović, Petar; Jeremić, Branislav; Gligorijević, Ivan

    2017-02-01

    Continuous and objective measurement of the user attention state still represents a major challenge in the ergonomics research. Recently available wearable electroencephalography (EEG) opens new opportunities for objective and continuous evaluation of operators' attention, which may provide a new paradigm in ergonomics. In this study, wearable EEG was recorded during simulated assembly operation, with the aim to analyse P300 event-related potential component, which provides reliable information on attention processing. In parallel, reaction times (RTs) were recorded and the correlation between these two attention-related modalities was investigated. Negative correlation between P300 amplitudes and RTs has been observed on the group level (p attention monitoring in ergonomics research. On the other hand, no significant correlation between RTs and P300 latency was found on group, neither on individual level. Practitioner Summary: Ergonomic studies of assembly operations mainly investigated physical aspects, while mental states of the assemblers were not sufficiently addressed. Presented study aims at attention tracking, using realistic workplace replica. It is shown that drops in attention could be successfully traced only by direct brainwave observation, using wireless electroencephalographic measurements.

  4. Modelling, verification, and calibration of a photoacoustics based continuous non-invasive blood glucose monitoring system.

    Science.gov (United States)

    Pai, Praful P; Sanki, Pradyut K; Sarangi, Satyabrata; Banerjee, Swapna

    2015-06-01

    This paper examines the use of photoacoustic spectroscopy (PAS) at an excitation wavelength of 905 nm for making continuous non-invasive blood glucose measurements. The theoretical background of the measurement technique is verified through simulation. An apparatus is fabricated for performing photoacoustic measurements in vitro on glucose solutions and in vivo on human subjects. The amplitude of the photoacoustic signals measured from glucose solutions is observed to increase with the solution concentration, while photoacoustic amplitude obtained from in vivo measurements follows the blood glucose concentration of the subjects, indicating a direct proportionality between the two quantities. A linear calibration method is applied separately on measurements obtained from each individual in order to estimate the blood glucose concentration. The estimated glucose values are compared to reference glucose concentrations measured using a standard glucose meter. A plot of 196 measurement pairs taken over 30 normal subjects on a Clarke error grid gives a point distribution of 82.65% and 17.35% over zones A and B of the grid with a mean absolute relative deviation (MARD) of 11.78% and a mean absolute difference (MAD) of 15.27 mg/dl (0.85 mmol/l). The results obtained are better than or comparable to those obtained using photoacoustic spectroscopy based methods or other non-invasive measurement techniques available. The accuracy levels obtained are also comparable to commercially available continuous glucose monitoring systems.

  5. Role of Continuous Glucose Monitoring in Clinical Trials: Recommendations on Reporting.

    Science.gov (United States)

    Schnell, Oliver; Barnard, Katharine; Bergenstal, Richard; Bosi, Emanuele; Garg, Satish; Guerci, Bruno; Haak, Thomas; Hirsch, Irl B; Ji, Linong; Joshi, Shashank R; Kamp, Maarten; Laffel, Lori; Mathieu, Chantal; Polonsky, William H; Snoek, Frank; Home, Philip

    2017-07-01

    Thanks to significant improvements in the precision, accuracy, and usability of continuous glucose monitoring (CGM), its relevance in both ambulatory diabetes care and clinical research is increasing. In this study, we address the latter perspective and derive provisional reporting recommendations. CGM systems have been available since around the year 2000 and used primarily in people with type 1 diabetes. In contrast to self-measured glucose, CGM can provide continuous real-time measurement of glucose levels, alerts for hypoglycemia and hyperglycemia, and a detailed assessment of glycemic variability. Through a broad spectrum of derived glucose data, CGM should be a useful tool for clinical evaluation of new glucose-lowering medications and strategies. It is the only technology that can measure hyperglycemic and hypoglycemic exposure in ambulatory care, or provide data for comprehensive assessment of glucose variability. Other advantages of current CGM systems include the opportunity for improved self-management of glycemic control, with particular relevance to those at higher risk of or from hypoglycemia. We therefore summarize the current status and limitations of CGM from the perspective of clinical trials and derive suggested recommendations for how these should facilitate optimal CGM use and reporting of data in clinical research.

  6. Ordering dynamics of microscopic models with nonconserved order parameter of continuous symmetry

    DEFF Research Database (Denmark)

    Zhang, Z.; Mouritsen, Ole G.; Zuckermann, Martin J.

    1993-01-01

    Numerical Monte Carlo temperature-quenching experiments have been performed on two three-dimensional classical lattice models with continuous ordering symmetry: the Lebwohl-Lasher model [Phys. Rev. A 6, 426 (1972)] and the ferromagnetic isotropic Heisenberg model. Both models describe a transition...... from a disordered phase to an orientationally ordered phase of continuous symmetry. The Lebwohl-Lasher model accounts for the orientational ordering properties of the nematic-isotropic transition in liquid crystals and the Heisenberg model for the ferromagnetic-paramagnetic transition in magnetic...

  7. Continuous monitoring of dissolved gases with membrane inlet mass spectrometry to fingerprint river biochemical activity

    Science.gov (United States)

    Vautier, Camille; Chatton, Eliot; Abbott, Benjamin; Harjung, Astrid; Labasque, Thierry; Guillou, Aurélie; Pannard, Alexandrine; Piscart, Christophe; Laverman, Anniet; Kolbe, Tamara; Massé, Stéphanie; de Dreuzy, Jean-Raynald; Thomas, Zahra; Aquilina, Luc; Pinay, Gilles

    2017-04-01

    Water quality in rivers results from biogeochemical processes in contributing hydrological compartments (soils, aquifers, hyporheic and riparian zones) and biochemical activity in the river network itself. Consequently, chemical fluxes fluctuate on multiple spatial and temporal scales, leading eventually to complex concentration signals in rivers. We characterized these fluctuations with innovative continuous monitoring of dissolved gases, to quantify transport and reaction processes occurring in different hydrological compartments. We performed stream-scale experiments in two headwater streams in Brittany, France. Factorial injections of inorganic nitrogen (NH4NO3), inorganic phosphate (P2O5) and multiple sources of labile carbon (acetate, tryptophan) were implemented in the two streams. We used a new field application of membrane inlet mass spectrometry to continuously monitor dissolved gases for multiple day-night periods (Chatton et al., 2016). Quantified gases included He, O2, N2, CO2, CH4, N2O, and 15N of dissolved N2 and N2O. We calibrated and assessed the methodology with well-established complementary techniques including gas chromatography and high-frequency water quality sensors. Wet chemistry and radon analysis complemented the study. The analyses provided several methodological and ecological insights and demonstrated that high frequency variations linked to background noise can be efficiently determined and filtered to derive effective fluxes. From a more fundamental point of view, the tested stream segments were fully characterized with extensive sampling of riverbeds and laboratory experiments, allowing scaling of point-level microbial and invertebrate diversity and activity on in-stream processing. This innovative technology allows fully-controlled in-situ experiments providing rich information with a high signal to noise ratio. We present the integrated nutrient demand and uptake and discuss limiting processes and elements at the reach and

  8. Test-retest reliability of a continuous glucose monitoring system in individuals with type 2 diabetes.

    Science.gov (United States)

    Terada, Tasuku; Loehr, Sarah; Guigard, Emmanuel; McCargar, Linda J; Bell, Gordon J; Senior, Peter; Boulé, Normand G

    2014-08-01

    This study determined the test-retest reliability of a continuous glucose monitoring system (CGMS) (iPro™2; Medtronic, Northridge, CA) under standardized conditions in individuals with type 2 diabetes (T2D). Fourteen individuals with T2D spent two nonconsecutive days in a calorimetry unit. On both days, meals, medication, and exercise were standardized. Glucose concentrations were measured continuously by CGMS, from which daily mean glucose concentration (GLU(mean)), time spent in hyperglycemia (t(>10.0 mmol/L)), and meal, exercise, and nocturnal mean glucose concentrations, as well as glycemic variability (SD(w), percentage coefficient of variation [%cv(w)], mean amplitude of glycemic excursions [MAGEc, MAGE(ave), and MAGE(abs.gos)], and continuous overlapping net glycemic action [CONGA(n)]) were estimated. Absolute and relative reliabilities were investigated using coefficient of variation (CV) and intraclass correlation, respectively. Relative reliability ranged from 0.77 to 0.95 (Pmeal, exercise, and nocturnal glycemia with CV ranging from 3.9% to 11.7%. Despite significant relative reliability (R=0.93; P10.0 mmol/L) showed larger CV (54.7%). Among the different glycemic variability measures, a significant between-day difference was observed in MAGEc, MAGE(ave), CONGA6, and CONGA12. The remaining measures (i.e., SD(w), %cv(w), MAGE(abs.gos), and CONGA1-4) indicated no between-day differences and significant relative reliability. In individuals with T2D, CGMS-estimated glycemic profiles were characterized by high relative and absolute reliability for both daily and shorter-term measurements as represented by GLUmean and meal, exercise, and nocturnal glycemia. Among the different methods to calculate glycemic variability, our results showed SD(w), %cv(w), MAGE(abs.gos), and CONGAn with n ≤ 4 were reliable measures. These results suggest the usefulness of CGMS in clinical trials utilizing repeated measured.

  9. Continuous monitoring of diffuse CO2 degassing at Taal volcano, Philippines

    Science.gov (United States)

    Padron, E.; Hernandez Perez, P. A.; Arcilla, C. A.; Lagmay, A. M. A.; Perez, N. M.; Quina, G.; Padilla, G.; Barrancos, J.; Cótchico, M. A.; Melián, G.

    2016-12-01

    Observing changes in the composition and discharge rates of volcanic gases is an important part of volcanic monitoring programs, because some gases released by progressive depressurization of magma during ascent are highly mobile and reach the surface well before their parental magma. Among volcanic gases, CO2 is widely used in volcano studies and monitoring because it is one of the earliest released gas species from ascending magma, and it is considered conservative. Taal Volcano in Southwest Luzon, Philippines, lies between a volcanic arc front (facing the subduction zone along the Manila Trench) and a volcanic field formed from extension beyond the arc front. Taal Volcano Island is formed by a main tuff cone surrounded by several smaller tuff cones, tuff rings and scoria cones. This island is located in the center of the 30 km wide Taal Caldera, now filled by Taal Lake. To monitor the volcanic activity of Taal volcano is a priority task in the Philippines, because several million people live within a 20-km radius of Taal's caldera rim. In the period from 2010-2011, during a period of volcanic unrest, the main crater lake of Taal volcano released the highest diffuse CO2 emission rates reported to date by volcanic lakes worldwide. The maximum CO2 emission rate measured in the study period occurred two months before the strongest seismic activity recorded during the unrest period (Arpa et al., 2013, Bull Volcanol 75:747). In the light of the excellent results obtained through diffuse degassing studies, an automatic geochemical station to monitor in a continuous mode the diffuse CO2 degassing in a selected location of Taal, was installed in January 2016 to improve the early warning system at the volcano. The station is located at Daang Kastila, at the northern portion of the main crater rim. It measures hourly the diffuse CO2 efflux, atmospheric CO2 concentration, soil water content and temperature, wind speed and direction, air temperature and humidity, rainfall

  10. Evaluation of different processing strategies of Continuous GPS (CGPS) observations for landslide monitoring

    Science.gov (United States)

    Ferhat, Gilbert; Malet, Jean-Philippe; Ulrich, Patrice

    2015-04-01

    The objective of this work is to evaluate several processing strategies of satellite navigation systems observations for the near-real time characterization of landslide displacement from continuous dual-frequency and mono-frequency GPS receivers. By tracking the electromagnetic waves that the satellites are sending continuously, the navigation system can provide the antenna position (longitude, latitude, and height, or X, Y, Z coordinates). The use of the phase measurements allows determining the relative positions of points located as far as several hundred kilometres apart with an accuracy of 2-5 mm in horizontal and 5-10 mm in vertical. This accuracy allows the fast detection of small displacements and, thus the survey of the temporal evolution of crustal deformation and natural hazards (volcanoes, tectonic faults, ice glaciers, landslides). Since a few years, several CGPS (Continuous Global Positioning System) receivers have been installed on active landslides in France (e.g. La Clapière rockslide, Avignonet and Villerville rotational slides, Super-Sauze and La Valette mudslides). These landslides show very different displacement rates (ranging from a few centimetres to several meters per year) and different kinematic regimes (e.g. continuous displacement of nearly constant rate or succession of periods of acceleration/deceleration). All landslides are part of the French 'Observatory of Landslides' (OMIV), a collaborative structure aiming at collecting the same type of kinematic, hydrologic and seismic observations on landslides and at disseminating the data to the scientific community. For the monitoring of landslides where the required degree of accuracy in position is about a few mm, GPS has been mainly used for repeated measurements, as a complement to conventional geodetic methods. Permanent monitoring is still not usually performed operationally on landslides mostly because of the cost of the receivers compared to conventional deformation monitoring

  11. A new topological parameter for monitoring subtle aggregation events in host-guest inclusion processes

    Science.gov (United States)

    Novato, Willian T. G.; De Almeida, Wagner B.; Dos Santos, Hélio F.

    2012-02-01

    Supramolecular complexes with cyclodextrin (CD) have been the subject of considerable research in the material and life sciences. The dynamics of systems are difficult to characterise, therefore, knowledge of the molecular features governing the host-guest equilibrium might aid in the design and practical application of the resulting inclusion complexes. In this Letter, we present a new topological parameter based on simple trigonometric considerations to be used to monitor subtle host-guest inclusion events along the molecular dynamics trajectory. The new topological descriptor, called vector-μ, was applied to amphetamine@α/β-CD inclusion complexes, providing interesting insights on the host-guest equilibrium.

  12. On the problem of monitoring the neutron parameters of the Fast Energy Amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Behringer, K.; Wydler, P

    1998-10-01

    The conceptual Fast Energy Amplifier, proposed by Rubbia et al. (1995), consists of a combination of a U-233/Th-232 fuelled fast-neutron subcritical facility with a proton accelerator. An intense beam of 1 GeV protons is injected into liquid lead at the core centre and drives the reactor by producing spallation neutrons. The burst of spallation neutrons produced by a single proton alters the basic neutron statistics which are well known for thermal neutrons in conventional nuclear reactors. A short assessment of standard neutron noise analysis methods is made with respect to monitoring neutron parameter data. (author) 18 refs., 14 figs., 3 tabs.

  13. Parameter monitoring system of the Dubna Gas-Filled Recoil Separator

    CERN Document Server

    Tsyganov, Y S; Sukhov, A M

    2015-01-01

    PC-based one-crate monitoring and control system of the Dubna Gas Filled Recoil Separator (DGFRS) is considered. It is developed for the long-term experiments at the U400 FLNR cyclotron and is aimed at the synthesis of super heavy nuclei in heavy ion induced complete fusion reactions. Parameters related to: a) beam and cyclotron; b) separator by itself, c) detection system, d) target and entrance window are measured and stored in the protocol file of the experiment. Special attention is paid to generating the alarm signals and implementing further the appropriate procedures

  14. Modelling and parameter estimation in reactive continuous mixtures: the catalytic cracking of alkanes - part II

    Directory of Open Access Journals (Sweden)

    F. C. PEIXOTO

    1999-09-01

    Full Text Available Fragmentation kinetics is employed to model a continuous reactive mixture of alkanes under catalytic cracking conditions. Standard moment analysis techniques are employed, and a dynamic system for the time evolution of moments of the mixture's dimensionless concentration distribution function (DCDF is found. The time behavior of the DCDF is recovered with successive estimations of scaled gamma distributions using the moments time data.

  15. Delay-dependent stability analysis for continuous-time BAM neural networks with Markovian jumping parameters.

    Science.gov (United States)

    Liu, Hongyang; Ou, Yan; Hu, Jun; Liu, Tingting

    2010-04-01

    This paper investigates the problem of stability analysis for bidirectional associative memory (BAM) neural networks with Markovian jumping parameters. Some new delay-dependent stochastic stability criteria are derived based on a novel Lyapunov-Krasovskii functional (LKF) approach. These new criteria based on the delay partitioning idea prove to be less conservative, since the conservatism could be notably reduced by thinning the delay partitioning. It is shown that the addressed stochastic BAM neural networks with Markovian jumping parameters are stochastically stable if three linear matrix inequalities (LMIs) are feasible. The feasibility of the LMIs can be readily checked by the Matlab LMI toolbox. A numerical example is provided to show the effectiveness and advantage of the proposed technique.

  16. Description of the behavior of an aquifer by using continuous radon monitoring in a thermal spa.

    Science.gov (United States)

    Sainz, Carlos; Rábago, Daniel; Fuente, Ismael; Celaya, Santiago; Quindós, Luis Santiago

    2016-02-01

    Radon ((222)Rn) levels in air and water have been analyzed continuously for almost a year in Las Caldas de Besaya thermal spa, north Spain. Radon is a naturally occurring noble gas from the decay of radium ((226)Ra) both constituents of radioactive uranium 238 series. It has been recognized as a lung carcinogen by the World Health Organization (WHO) and International Agency for Research on Cancer (IARC). Furthermore the Royal Decree R.D 1439/2010 of November, 2010 establishes the obligation to study occupational activities where workers and, where appropriate, members of the public are exposed to inhalation of radon in workplaces such as spas. Together with radon measures several physico-chemical parameters were obtained such as pH, redox potential, electrical conductivity and air and water temperature. The devices used for the study of the temporal evolution of radon concentration have been the RTM 2100, the Radon Scout and gamma spectrometry was complementarily used to determine the transfer factor of the silicone tubes in the experimental device. Radon concentrations obtained in water and air of the spa are high, with an average of 660 Bq/l and 2900 Bq/m(3) respectively, where water is the main source of radon in the air. Radiation dose for workers and public was estimated from these levels of radon. The data showed that the thermal processes can control the behavior of radon which can be also influenced by various physical and chemical parameters such as pH and redox potential.

  17. Identification and optimization of parameters for the semi-continuous production of garbage enzyme from pre-consumer organic waste by green RP-HPLC method.

    Science.gov (United States)

    Arun, C; Sivashanmugam, P

    2015-10-01

    Reuse and management of organic solid waste, reduce the environmental impact on human health and increase the economic status by generating valuable products for current and novel applications. Garbage enzyme is one such product produced from fermentation of organic solid waste and it can be used as liquid fertilizer, antimicrobial agents, treatment of domestic wastewater, municipal and industrial sludge treatment, etc. The semi-continuous production of garbage enzyme in large quantity at minimal time period and at lesser cost is needed to cater for treatment of increasing quantities of industrial waste activated sludge. This necessitates a parameter for monitoring and control for the scaling up of current process on semi-continuous basis. In the present study a RP-HPLC (Reversed Phase-High Performance Liquid Chromatography) method is used for quantification of standard organic acid at optimized condition 30°C column oven temperature, pH 2.7, and 0.7 ml/min flow rate of the mobile phase (potassium dihydrogen phosphate in water) at 50mM concentration. The garbage enzyme solution collected in 15, 30, 45, 60, 75 and 90 days were used as sample to determine the concentration of organic acid. Among these, 90th day sample showed the maximum concentration of 78.14 g/l of acetic acid in garbage enzyme, whereas other organic acids concentration got decreased when compare to the 15th day sample. This result confirms that the matured garbage enzyme contains a higher concentration of acetic acid and thus it can be used as a monitoring parameter for semi-continuous production of garbage enzyme in large scale.

  18. PARAMETERS OPTIMIZATION OF CONTINUOUS WAVELET TRANSFORM AND ITS APPLICATION IN ACOUSTIC EMISSION SIGNAL ANALYSIS OF ROLLING BEARING

    Institute of Scientific and Technical Information of China (English)

    ZHANG Xinming; HE Yongyong; HAO Rujiang; CHU Fulei

    2007-01-01

    Morlet wavelet is suitable to extract the impulse components of mechanical fault signals.And thus its continuous wavelet transform (CWT) has been successfully used in the field of fault diagnosis. The principle of scale selection in CWT is discussed. Based on genetic algorithm, an optimization strategy for the waveform parameters of the mother wavelet is proposed with wavelet entropy as the optimization target. Based on the optimized waveform parameters, the wavelet scalogram is used to analyze the simulated acoustic emission (AE) signal and real AE signal of rolling bearing.The results indicate that the proposed method is useful and efficient to improve the quality of CWT.

  19. A modular backend computing system for continuous civil structural health monitoring

    Science.gov (United States)

    Chien, Ting-Chou; Huo, Chengjia; Chou, Pai H.

    2014-04-01

    This paper describes a computing backend for a water pipe monitoring system. Today, most such systems are divided into event-triggered and continuous monitoring, but they all lack systematic handling of data. Many systems simply store data in files with specific naming conventions and ad hoc formats, making them difficult to retrieve, maintain, disseminate, and analyze. To address these problems, our backend supports data management and dissemination. Unlike previous systems that store data in files or conventional databases before analysis, our modular architecture not only saves data in efficiently searchable ways by indexing as a baseline dataset but also detected events in discrete time manner and other processed data. To facilitate analysis, we design a plug-in structure to allow processing modules to perform inline processing and shorten detection time. For data dissemination, our architecture can compose multiple visualizations including geographical maps to create powerful tools to yield new insight into massive datasets. The backend system enables Internet web service for visualization, data management, and remote sensor control for better integration. Our system is applicable to not only water pipelines but also bridges and civil structures in general. Our proposed backend system has been implemented and validated through field deployment. One such system has been running for over 1.5 years and has collected millions of records to date. A Google Map integrated visualization service has been developed to demonstrate lively collected records in real-time. This is expected to be more helpful for better understanding of civil structures' behavior in the long term.

  20. Beer fermentation: monitoring of process parameters by FT-NIR and multivariate data analysis.

    Science.gov (United States)

    Grassi, Silvia; Amigo, José Manuel; Lyndgaard, Christian Bøge; Foschino, Roberto; Casiraghi, Ernestina

    2014-07-15

    This work investigates the capability of Fourier-Transform near infrared (FT-NIR) spectroscopy to monitor and assess process parameters in beer fermentation at different operative conditions. For this purpose, the fermentation of wort with two different yeast strains and at different temperatures was monitored for nine days by FT-NIR. To correlate the collected spectra with °Brix, pH and biomass, different multivariate data methodologies were applied. Principal component analysis (PCA), partial least squares (PLS) and locally weighted regression (LWR) were used to assess the relationship between FT-NIR spectra and the abovementioned process parameters that define the beer fermentation. The accuracy and robustness of the obtained results clearly show the suitability of FT-NIR spectroscopy, combined with multivariate data analysis, to be used as a quality control tool in the beer fermentation process. FT-NIR spectroscopy, when combined with LWR, demonstrates to be a perfectly suitable quantitative method to be implemented in the production of beer.

  1. A multistep algorithm for processing and calibration of microdialysis continuous glucose monitoring data.

    Science.gov (United States)

    Mahmoudi, Zeinab; Dencker Johansen, Mette; Christiansen, Jens Sandahl; Hejlesen, Ole Kristian

    2013-10-01

    The deviation of continuous subcutaneous glucose monitoring (CGM) data from reference blood glucose measurements is substantial, and adequate signal processing is required to reduce the discrepancy between subcutaneous glucose and blood glucose values. The purpose of this study was to develop a multistep algorithm for the processing and calibration of continuous subcutaneous glucose monitoring data with high accuracy and short delay. Algorithm The algorithm comprises three steps: rate-limiting filtering, selective smoothing, and robust calibration. Initially, the algorithm detects nonphysiological glucose rate-of-change and corrects it with a weighted local polynomial. Noisy signal parts that require smoothing are then detected based on zero crossing count of the sensor signal first-order differences, and an exponentially weighted moving average smooths the noisy parts of the signal afterward. Finally, calibration is performed using a first-order polynomial as the conversion function, with coefficients being estimated using robust regression with a bi-square weight function. ALGORITHM PERFORMANCE: The performance of the algorithm was evaluated on 16 patients with type 1 diabetes mellitus. To compare the algorithm with state-of-the-art CGM data denoising and calibration, the rate-limiting filter and selective smoothing were replaced with an adaptive Kalman filter, and the calibration method was replaced with the calibration algorithm presented in one of the Medtronic (Northridge, CA) CGM patents. The median (mean) of the absolute relative deviation (ARD) of the sensor glucose values processed by the newly developed algorithm from capillary reference blood glucose measurements was 14.8% (22.6%), 10.6% (14.6%), and 8.9% (11.7%) in hypoglycemia, euglycemia, and hyperglycemia, respectively, whereas for the alternative algorithm, the median (mean) was 22.2% (26.9%), 12.1% (15.9%), and 8.8 (11.3%), respectively. The median (mean) ARD in all ranges was 10.3% (14.7%) for

  2. Ventilation rates in large commercial layer hen houses with two-year continuous monitoring.

    Science.gov (United States)

    Chai, L; Ni, J-Q; Diehl, C A; Kilic, I; Heber, A J; Chen, Y; Cortus, E L; Bogan, B W; Lim, T T; Ramirez-Dorronsoro, J-C; Chen, L

    2012-01-01

    1. Ventilation controls the indoor environment and is critical for poultry production and welfare. Ventilation is also crucial for assessing aerial pollutant emissions from the poultry industry. Published ventilation data for commercial layer houses have been limited, and are mostly based on short-term studies, mainly because monitoring airflow from large numbers of fans is technically challenging. 2. A two-year continuous ventilation monitoring trial was conducted at two commercial manure belt houses (A and B), each with 250 000 layers and 88 130-cm exhaust fans. All the fans were individually monitored with fan rotational speed sensors or vibration sensors. Differential static pressures across the house walls were also measured. Three fan performance assessment methods were applied periodically to determine fan degradations. Fan models were developed to calculate house ventilations. 3. A total of 693 and 678 complete data days, each containing >16 h of valid ventilation data, were obtained in houses A and B, respectively. The two-year mean ventilation rates of houses A and B were 2·08 and 2·10 m(3) h(-1) hen(-1), corresponding to static pressures of -36·5 and -48·9 Pa, respectively. For monthly mean ventilation, the maximum rates were 4·87 and 5·01 m(3) h(-1) hen(-1) in July 2008, and the minimum were 0·59 and 0·81 m(3) h(-1) hen(-1) in February 2008, for houses A and B, respectively. 4. The two-year mean ventilation rates were similar to those from a survey in Germany and a 6-month study in Indiana, USA, but were much lower than the 8·4 and 6·2 m(3) h(-1) hen(-1) from a study in Italy. The minimum monthly mean ventilation rates were similar to the data obtained in winter in Canada, but were lower than the minimum ventilation suggested in the literature. The lower static pressure in house B required more ventilation energy input. The two houses, although identical, demonstrated differences in indoor environment controls

  3. Citizen Hydrology - Tradeoffs between Traditional Continuous Approaches and Temporally Discrete Hydrologic Monitoring

    Science.gov (United States)

    Davids, Jeffrey; Rutten, Martine; van de Giesen, Nick; Mehl, Steffen; Norris, James

    2016-04-01

    Traditional approaches to hydrologic data collection rely on permanent installations of sophisticated and relatively accurate but expensive monitoring equipment at limited numbers of sites. Consequently, the spatial coverage of the data is limited and the cost is high. Moreover, achieving adequate maintenance of the sophisticated equipment often exceeds local technical and resource capacity, and experience has shown that permanently deployed monitoring equipment is susceptible to vandalism, theft, and other hazards. Rather than using expensive, vulnerable installations at a few points, SmartPhones4Water (S4W), a form of citizen science, leverages widely available mobile technology to gather hydrologic data at many sites in a manner that is highly repeatable and scalable. The tradeoff for increased spatial resolution, however, is reduced observation frequency. As a first step towards evaluating the tradeoffs between the traditional continuous monitoring approach and emerging citizen science methods, 50 U.S. Geological Survey (USGS) streamflow gages were randomly selected from the population of roughly 350 USGS gages operated in California. Gaging station metadata and historical 15 minute flow data for the period from 01/10/2007 through 31/12/2014 were compiled for each of the selected gages. Historical 15 minute flow data were then used to develop daily, monthly, and yearly determinations of average, minimum, maximum streamflow, cumulative runoff, and streamflow distribution. These statistics were then compared to similar statistics developed from randomly selected daily and weekly spot measurements of streamflow. Cumulative runoff calculated from daily and weekly observations were within 10 percent of actual runoff calculated from 15 minute data for 75 percent and 46 percent of sites respectively. As anticipated, larger watersheds with less dynamic temporal variability compared more favorably for all statistics evaluated than smaller watersheds. Based on the

  4. Using Stochastic modelling to identify unusual continuous glucose monitor measurements and behaviour, in newborn infants

    Directory of Open Access Journals (Sweden)

    Signal Matthew

    2012-08-01

    Full Text Available Abstract Background Abnormal blood glucose (BG concentrations have been associated with increased morbidity and mortality in both critically ill adults and infants. Furthermore, hypoglycaemia and glycaemic variability have both been independently linked to mortality in these patients. Continuous Glucose Monitoring (CGM devices have the potential to improve detection and diagnosis of these glycaemic abnormalities. However, sensor noise is a trade-off of the high measurement rate and must be managed effectively if CGMs are going to be used to monitor, diagnose and potentially help treat glycaemic abnormalities. Aim To develop a tool that will aid clinicians in identifying unusual CGM behaviour and highlight CGM data that potentially need to be interpreted with care. Methods CGM data and BG measurements from 50 infants at risk of hypoglycaemia were used. Unusual CGM measurements were classified using a stochastic model based on the kernel density method and historical CGM measurements from the cohort. CGM traces were colour coded with very unusual measurements coloured red, highlighting areas to be interpreted with care. A 5-fold validation of the model was Monte Carlo simulated 25 times to ensure an adequate model fit. Results The stochastic model was generated using ~67,000 CGM measurements, spread across the glycaemic range ~2-10 mmol/L. A 5-fold validation showed a good model fit: the model 80% confidence interval (CI captured 83% of clinical CGM data, the model 90% CI captured 91% of clinical CGM data, and the model 99% CI captured 99% of clinical CGM data. Three patient examples show the stochastic classification method in use with 1 A stable, low variability patient which shows no unusual CGM measurements, 2 A patient with a very sudden, short hypoglycaemic event (classified as unusual, and, 3 A patient with very high, potentially un-physiological, glycaemic variability after day 3 of monitoring (classified as very unusual. Conclusions

  5. In vivo continuous glucose monitoring using a chip based near infrared sensor

    Science.gov (United States)

    Ben Mohammadi, L.; Sigloch, S.; Frese, I.; Welzel, K.; Göddel, M.; Klotzbücher, T.

    2014-05-01

    Diabetes is a serious health condition considered to be one of the major healthcare epidemics of modern era. An effective treatment of this disease can be only achieved by reliable continuous information on blood glucose levels. In this work we present a minimally invasive, chip-based near infrared (NIR) sensor, combined with microdialysis, for continuous glucose monitoring (CGM). The sensor principle is based on difference absorption spectroscopy in the 1st overtone band of the near infrared spectrum. The device features a multi-emitter LED and InGaAs-Photodiodes, which are located on a single electronic board (non-disposable part), connected to a personal computer via Bluetooth. The disposable part consists of a chip containing the fluidic connections for microdialysis, two fluidic channels acting as optical transmission cells and total internally reflecting mirrors for in- and out-coupling of the LED light to the chip and to the detectors. The sensor is combined with an intraveneous microdialysis to separate the glucose from the cells and proteins in the blood and operates without any chemical consumption. In vitro measurements showed a linear relationship between glucose concentration and the integrated difference signal with a coefficient of determination of 99 % in the relevant physiological concentration range from 0 to 400 mg/dl. In vivo measurements on 10 patients showed that the NIR-CGM sensor data reflects the blood reference values adequately, if a proper calibration and signal drift compensation is applied. The MARE (mean absolute relative error) value taken over all patient data is 13.8 %. The best achieved MARE value is at 4.8 %, whereas the worst is 25.8 %, with a standard deviation of 5.5 %.

  6. Continuous nasogastric tube feeding: monitoring by combined use of refractometry and traditional gastric residual volumes.

    Science.gov (United States)

    Chang, W-K; McClave, S-A; Chao, Y-C

    2004-02-01

    Traditional use of gastric residual volumes (GRVs) is insensitive and cannot distinguish retained enteral formula from the large volume of endogenous secretions. We designed this prospective study to determine whether refractometry and Brix value (BV) measurements could be used to monitor gastric emptying and tolerance in patients receiving continuous enteral feeding. Thirty-six patients on continuous nasogastric tube feeding were divided into two groups; patients with lower GRVs (75 ml) in Group 2. Upon entry, all gastric contents were aspirated, the volume was recorded (Asp GRV), BV measurements were made by refractometry, and then the contents were reinstilled but diluted with 30 ml additional water. Finally, a small amount was reaspirated and repeat BV measurements were made. Three hours later, the entire procedure was repeated a second time. The BV ratio, calculated (Cal) GRV, and volume of formula remaining were calculated by derived equations. Mean BV ratios were significantly higher for those patients in Group 2 compared to those in Group 1. All but one of the 22 patients (95%) in Group 1 had a volume of formula remaining in the stomach estimated on both measurements to be less than the hourly infusion rate (all these patients had BV ratios 70%). Three of the Group 2 patients (21%) whose initial measurement showed evidence for retention of formula, improved on repeat follow-up measurement assuring adequate gastric emptying. The remaining five patients from Group 2 (35%) had a volume of formula remaining that was less than the hourly infusion rate on both measurements. The pattern of Asp GRVs and serial pre- and post-dilution BVs failed to differentiate these patients in Group 2 with potential emptying problems from those with sufficient gastric emptying. Refractometry and measurement of the BV may improve the clinical utilization of GRVs, by its ability to identify the component of formula within gastric contents and track changes in that component related

  7. Test report on the machine-mounted continuous respirable dust monitor

    Energy Technology Data Exchange (ETDEWEB)

    Kissell, F.N.; Thimons, E.D. [Pittsburgh Research Laboratory, Pittsburgh, PA (USA). National Institute for Occupational Safety and Health

    2001-07-01

    The machine-mounted continuous respirable dust monitor (MMCRDM) is a fixed-location area sampling device developed for possible use at the working face of an underground coal mine. This device, based on proprietary technology known as the tapered element oscillating microbalance, has evolved over the past eight years through a cooperative effort of the former Bureau of Mines, MSHA, and the Rupprecht & Patashnick Company in Albany, NY. The capability to measure respirable coal mine dust levels on a continuous basis, rather than depending solely on periodic samples obtained from the traditional coal mine dust samplers, has been a goal in the mining industry for nearly two decades. Recently, an extensive series of laboratory and underground tests was conducted by NIOSH with the cooperation of MSHA and coal operators to test the performance of the MMCRDM. In preliminary laboratory testing, the MMCRDM seemed to work well. However, in every underground test, when compared to reference samplers placed close to the inlet, the MMCRDM failed to meet the 25% accuracy criterion specified in the contract under which it was developed. Two reasons explain this failure: first, in most tests the bias (the relative discrepancy between the average MMCRDM concentration and the average reference sampler concentration) was too great. Second, the variability of the samplers used for reference comparison was too large. Finally, the underground testing of the MMCRDMs showed that they are quite unreliable at this stage of development. In the majority of mine tests, no more than 10 shifts of data were taken before the MMCRDM failed to function properly. Major breakdowns, requiring the return of the MMCRDM to the factory for repairs, occurred on average every 28 days. To be considered mine-worthy, MMCRDM reliability must be substantially improved. 6 refs., 7 figs.

  8. Effect of austempering parameters on microstructure and mechanical properties of horizontal continuous casting ductile iron dense bars

    OpenAIRE

    Chun-jie Xu; Pan Dai; Zheng-yang Zhang

    2015-01-01

    In the present research, the orthogonal experiment was carried out to investigate the influence of different austempering process parameters (i.e. austenitizing temperature and time, and austempering temperature and time) on microstructure and mechanical properties of LZQT500-7 ductile iron dense bars with 172 mm in diameter which were produced by horizontal continuous casting (HCC). The results show that the major factors influencing the hardness of austempered ductile iron (ADI) are austeni...

  9. Parameter Optimization of Information Channels for Laser Fluorescence Method of Vegetation Monitoring

    Directory of Open Access Journals (Sweden)

    M. L. Belov

    2015-01-01

    Full Text Available Nowadays, there is a growing interest in application of remote monitoring and accounting systems in agriculture.One of the promising areas of remote vegetation monitoring is a fluorescence analysis, as it potentially allows sensing stress of plants according to characteristics of their fluorescent radiation.The shape of the fluorescence spectra of vegetation in the normal condition differs from that of the fluorescence spectra of vegetation in stressful conditions. This potentially allows you to sence the plants by recording information about the shape of the fluorescence spectra.Analysis of the fluorescence spectrum shape can be replaced by the analysis of fluorescence intensities in several spectral bands, which simpifies problem-solving.Currently, there are various devices developed for laser fluorescence sensing of plant stress. However, a lot of issues important to the practice remain unclear.Most of these issues concern the parameters of receiving channels to record information signals, which allow you to perceve the stress-sensed plants:- how many information channels of spectral bands better to use;- what the best width of these spectral bands of information is ;- what is the best width of the spectral bands of information;- what the best threshold value for the threshold algorithm is, and if there is the better algorithm to process measurement data.The work uses mathematical modeling based on the experimentally measured fluorescence spectra to determine the optimal (in terms of probability of sensing characteristics of the stress of plants, i.e. the probability of good sense and false alarm parameters of information channels for laser fluorescence method to sense the plant stress: the central wavelength of the information spectral bands, their spectral width, and parameters of the algorithm in the case of processing two spectral channels of information. It is shown that using the additional third information spectral band allows you to

  10. Design of a DCS Based Model for Continuous Leakage Monitoring System of Rotary Air Preheater of a Thermal Power Plant

    Directory of Open Access Journals (Sweden)

    Madan BHOWMICK

    2011-01-01

    Full Text Available The leakage in rotary air preheater makes a considerable contribution to the reduced overall efficiency of fossil-fuel-fired thermal power plants and increase the effect on environment. Since it is normal phenomenon, continuous monitoring of leakage is generally omitted in most power plants. But for accurate analysis of the operation of the thermal power plant, this leakage monitoring plays a vital role. In the present paper, design of a DCS based model for continuous leakages monitoring of rotary air preheater has been described. In the proposed model, the existing DCS based instrumentation system has been modified and online leakage monitoring system has been developed. This model has been installed in a captive power plant with high capacity boilers and very much satisfactory operation of this system has been observed. The observed online data along with their analysis results are presented in this paper.

  11. Environmental effects of radon and its progeny from uranium waste rock piles. Pt. 1. Measurements by passive and continuous monitors

    Energy Technology Data Exchange (ETDEWEB)

    Ishimori, Yuu; Ito, Kimio; Furuta, Sada-aki [Ningyo Toge Works, Power Reactor and Nuclear Fuel Development Corporation, Kamisaibara, Okayama (Japan)

    1998-12-31

    The radon concentration in atmosphere on and around the uranium waste rock pile sites has been measured by integrating passive monitors since 1989. In fiscal 1996, except for the Katamo-shimo 1, the average concentration of radon on the sites, around the sites and in control areas, ranged from 11 to 194 Bq/m{sup 3} (average: 45 Bq/m{sup 3}), from 8 to 75 Bq/m{sup 3} (average: 26 Bq/m{sup 3}), and from 9 to 77 Bq/m{sup 3} (average: 30 Bq/m{sup 3}), respectively. Additionally, the typical daily and seasonal variations of radon concentration, radon progeny concentration and radon exhalation rate are observed with continuous or automatic monitors. According to the measurement results by passive monitors and continuous monitors, the environmental effects of radon and its progeny from the waste rock pile sites are estimated small in residential regions around the sites. (author)

  12. Scheduling and calibration strategy for continuous radio monitoring of 1700 sources every three days

    CERN Document Server

    Max-Moerbeck, Walter

    2014-01-01

    The Owens Valley Radio Observatory 40 meter telescope is currently monitoring a sample of about 1700 blazars every three days at 15 GHz, with the main scientific goal of determining the relation between the variability of blazars at radio and gamma-rays as observed with the Fermi Gamma-ray Space Telescope. The time domain relation between radio and gamma-ray emission, in particular its correlation and time lag, can help us determine the location of the high-energy emission site in blazars, a current open question in blazar research. To achieve this goal, continuous observation of a large sample of blazars in a time scale of less than a week is indispensable. Since we only look at bright targets, the time available for target observations is mostly limited by source observability, calibration requirements and slewing of the telescope. Here I describe the implementation of a practical solution to this scheduling, calibration, and slewing time minimization problem. This solution combines ideas from optimization,...

  13. Scheduling and calibration strategy for continuous radio monitoring of 1700 sources every three days

    Science.gov (United States)

    Max-Moerbeck, Walter

    2014-08-01

    The Owens Valley Radio Observatory 40 meter telescope is currently monitoring a sample of about 1700 blazars every three days at 15 GHz, with the main scientific goal of determining the relation between the variability of blazars at radio and gamma-rays as observed with the Fermi Gamma-ray Space Telescope. The time domain relation between radio and gamma-ray emission, in particular its correlation and time lag, can help us determine the location of the high-energy emission site in blazars, a current open question in blazar research. To achieve this goal, continuous observation of a large sample of blazars in a time scale of less than a week is indispensable. Since we only look at bright targets, the time available for target observations is mostly limited by source observability, calibration requirements and slewing of the telescope. Here I describe the implementation of a practical solution to this scheduling, calibration, and slewing time minimization problem. This solution combines ideas from optimization, in particular the traveling salesman problem, with astronomical and instrumental constraints. A heuristic solution using well established optimization techniques and astronomical insights particular to this situation, allow us to observe all the sources in the required three days cadence while obtaining reliable calibration of the radio flux densities. Problems of this nature will only be more common in the future and the ideas presented here can be relevant for other observing programs.

  14. A Wireless Pressure Sensor for Continuous Monitoring of Intraocular Pressure in Conscious Animals.

    Science.gov (United States)

    Bello, Simon A; Passaglia, Christopher L

    2017-08-15

    An important aspect of eye health in humans and animal models of human diseases is intraocular pressure (IOP). IOP is typically measured by hand with a tonometer, so data are sparse and sporadic and round-the-clock variations are not well characterized. Here we present a novel system for continuous wireless IOP and temperature measurement in small animals. The system consists of a cannula implanted in the anterior chamber of the eye connected to pressure sensing electronics that can be worn by rats or implanted in larger mammals. The system can record IOP with 0.3 mmHg accuracy and negligible drift at a rate of 0.25 Hz for 1-2 months on a regulated battery or indefinitely at rates up to 250 Hz via RF energy harvesting. Chronic recordings from conscious rats showed that IOP follows a diurnal rhythm, averaging 16.5 mmHg during the day and 21.7 mmHg at night, and that the IOP rhythm lags a diurnal rhythm in body temperature by 2.1 h. IOP and body temperature fluctuations were positively correlated from moment-to-moment as well. This technology allows researchers to monitor for the first time the precise IOP history of rat eyes, a popular model for glaucoma studies.

  15. Continuous wide area monitoring of fish shoaling behavior with acoustic waveguide sensing and bioclutter implications

    Science.gov (United States)

    Makris, Nicholas C.; Ratilal, Purnima; Symonds, Deanelle T.; Nero, Redwood W.

    2001-05-01

    Field measurements are used to show that the detailed behavior of fish shoals can be continuously monitored at roughly 1-min intervals over wide areas spanning hundreds of square kilometers by long range acoustic waveguide sensing. The technique was used on the New Jersey Continental Shelf to produce unprecedented video images of shoal formation, fragmentation, and migration. Simultaneous line-transect measurements show the imaged shoals to contain pelagic fish with densities of at least one individual per meter3. The technique relies upon acoustic waveguide propagation in the continental shelf. Here, trapped modes dominate propagation and suffer only cylindrical spreading loss rather than the spherical loss suffered in free-space transmission or short-range propagation in the ocean. In contrast, standard methods for fish surveyance involve line transect measurements from slow moving research vessels that significantly under-sample fish distributions in time and space, leaving an incomplete behavioral picture. The implications of this bioclutter phenomenon on the Navy's long range active sonar operations in continental shelf environments are discussed.

  16. Water security: continuous monitoring of water distribution systems for chemical agents by SERS

    Science.gov (United States)

    Inscore, Frank; Shende, Chetan; Sengupta, Atanu; Farquharson, Stuart

    2007-04-01

    Ensuring safe water supplies requires continuous monitoring for potential poisons and portable analyzers to map distribution in the event of an attack. In the case of chemical warfare agents (CWAs) analyzers are needed that have sufficient sensitivity (part-per-billion), selectivity (differentiate the CWA from its hydrolysis products), and speed (less than 10 minutes) to be of value. We have been investigating the ability of surface-enhanced Raman spectroscopy (SERS) to meet these requirements by detecting CWAs and their hydrolysis products in water. The expected success of SERS is based on reported detection of single molecules, the one-to-one relationship between a chemical and its Raman spectrum, and the minimal sample preparation requirements. Recently, we have developed a simple sampling device designed to optimize the interaction of the target molecules with the SERS-active material with the goal of increasing sensitivity and decreasing sampling times. This sampling device employs a syringe to draw the water sample containing the analyte into a capillary filled with the SERS-active material. Recently we used such SERS-active capillaries to measure 1 ppb cyanide in water. Here we extend these measurements to nerve agent hydrolysis products using a portable Raman analyzer.

  17. A novel method about online monitoring surface shape of optical elements in continuous polishing

    Science.gov (United States)

    Yin, Jin; Zhu, Jianqiang; Jiao, Xiang; Wu, Yongzhong

    2016-10-01

    In conventional continuous polishing process, the surface shape of work-piece was measured by an optical plane template after being placed in such environment with constant temperature for 1 to 2 hours. During this period, uncertain influence may occur on the polishing pad due to the change of system state. Meanwhile, the regular off-line testing may cause re-processing. In this paper, a new method about on-line monitoring surface shape of optical elements is proposed by the theory of run sphere, and the change in curvature radius of the work-piece which lead to its radial tilt angle change. The change in work-piece surface shape indirectly obtain by the correction plate small angle with respect to the horizontal, and the angle were detected on line by the high-precision goniometer with the resolution 0.04 ''. According to theoretical calculations, the diameter of 200mm precision work-piece PV value up to 0.02λ (λ = 632.8nm). The fused quartz glass was measured by above method. The test results showed that the surface accuracy and processing efficiency were significantly promoted, and also improving the controllability of surface shape of work-piece based on this method.

  18. Use of continuous monitoring to assess stream nitrate flux and transformation patterns.

    Science.gov (United States)

    Jones, Christopher; Kim, Sea-Won; Schilling, Keith

    2017-01-01

    Delivery of nitrogen from farmed fields to the stream network is an ongoing water quality issue in central North America and other parts of the world. Although fertilization and other farming practices have been refined to produce environmental improvements, stemming loss of nitrogen, especially in the soluble nitrate form, is a problem that has seemingly defied solution. The Iowa Nutrient Reduction Strategy is a policy initiative designed to implement conservation and other farm management practices to produce reductions in nitrate loading. The strategy does not focus on how the streams themselves may or may not be processing nitrogen and reducing downstream loading. We used continuous high-frequency nitrate and discharge monitoring over 3 years at two sites separated by 18 km in a low-order, agricultural stream in eastern Iowa to estimate how nitrogen is processed, and whether or not these processes are reducing downstream loading. We conclude that the upstream to downstream nitrate concentration decline between the two sites was not driven by denitrification. These data also show that nitrate concentrations are closely coupled to discharge during periods of adequate moisture, but decoupling of concentration from discharge occurs during dry periods. This decoupling is a possible indicator of in-stream nitrate processing. Finally, nitrate concentrations are likely diluted by water sourced from non-row crop land covers in the lower reaches of the watershed.

  19. Regularised Model Identification Improves Accuracy of Multisensor Systems for Noninvasive Continuous Glucose Monitoring in Diabetes Management

    Directory of Open Access Journals (Sweden)

    Mattia Zanon

    2013-01-01

    Full Text Available Continuous glucose monitoring (CGM by suitable portable sensors plays a central role in the treatment of diabetes, a disease currently affecting more than 350 million people worldwide. Noninvasive CGM (NI-CGM, in particular, is appealing for reasons related to patient comfort (no needles are used but challenging. NI-CGM prototypes exploiting multisensor approaches have been recently proposed to deal with physiological and environmental disturbances. In these prototypes, signals measured noninvasively (e.g., skin impedance, temperature, optical skin properties, etc. are combined through a static multivariate linear model for estimating glucose levels. In this work, by exploiting a dataset of 45 experimental sessions acquired in diabetic subjects, we show that regularisation-based techniques for the identification of the model, such as the least absolute shrinkage and selection operator (better known as LASSO, Ridge regression, and Elastic-Net regression, improve the accuracy of glucose estimates with respect to techniques, such as partial least squares regression, previously used in the literature. More specifically, the Elastic-Net model (i.e., the model identified using a combination of and norms has the best results, according to the metrics widely accepted in the diabetes community. This model represents an important incremental step toward the development of NI-CGM devices effectively usable by patients.

  20. Real-time continuous glucose monitoring systems in the classroom/school environment.

    Science.gov (United States)

    Benassi, Kari; Drobny, Jessica; Aye, Tandy

    2013-05-01

    Children with type 1 diabetes (T1D) spend 4-7 h/day in school with very little supervision of their diabetes management. Therefore, families have become more dependent on technology, such as use of real-time continuous glucose monitoring (RT-CGM), to provide increased supervision of their diabetes management. We sought to assess the impact of RT-CGM use in the classroom/school environment. Children with T1D using RT-CGM, their parents, and teachers completed a questionnaire about RT-CGM in the classroom/school environment. The RT-CGM was tolerated well in the classroom/school environment. Seventy percent of parents, 75% of students, and 51% of teachers found RT-CGM useful in the classroom/school environment. The students found the device to be more disruptive than did their parents and teachers. However, all three groups agreed that RT-CGM increased their comfort with diabetes management at school. Our study suggests that RT-CGM is useful and not disruptive in the classroom/school environment. The development of education materials for teachers could further increase its acceptance in the classroom/school environment.

  1. Continuous glucose monitoring-enabled insulin-pump therapy in diabetic pregnancy

    DEFF Research Database (Denmark)

    Secher, Anna L; Schmidt, Signe; Nørgaard, Kirsten;

    2010-01-01

    We describe the feasibility of continuous glucose monitoring (CGM)-enabled insulin-pump therapy during pregnancy in a woman with type 1 diabetes, who was treated with CGM-enabled insulin-pump therapy in her third pregnancy. During her first pregnancy, the woman was treated with multiple daily...... injections and baseline HbA1c was 8.9%. Due to pre-eclampsia, the child was born preterm, and had neonatal hypoglycemia. In the planning of the second pregnancy, insulin-pump therapy was initiated, resulting in an HbA1c of 6.8% in early pregnancy. Due to pre-eclampsia, the second child was born preterm......, but without neonatal morbidity. Before her third pregnancy, CGM-enabled insulin-pump therapy was introduced, and HbA1c was 6.4% in early pregnancy. The patient was satisfied with this therapy, pre-eclampsia did not occur, and the child was born at term without neonatal morbidity. CGM-enabled insulin...

  2. Continuous glucose monitoring-enabled insulin-pump therapy in diabetic pregnancy

    DEFF Research Database (Denmark)

    Secher, Anna L; Schmidt, Signe; Nørgaard, Kirsten

    2010-01-01

    We describe the feasibility of continuous glucose monitoring (CGM)-enabled insulin-pump therapy during pregnancy in a woman with type 1 diabetes, who was treated with CGM-enabled insulin-pump therapy in her third pregnancy. During her first pregnancy, the woman was treated with multiple daily...... injections and baseline HbA1c was 8.9%. Due to pre-eclampsia, the child was born preterm, and had neonatal hypoglycemia. In the planning of the second pregnancy, insulin-pump therapy was initiated, resulting in an HbA1c of 6.8% in early pregnancy. Due to pre-eclampsia, the second child was born preterm......, but without neonatal morbidity. Before her third pregnancy, CGM-enabled insulin-pump therapy was introduced, and HbA1c was 6.4% in early pregnancy. The patient was satisfied with this therapy, pre-eclampsia did not occur, and the child was born at term without neonatal morbidity. CGM-enabled insulin-pump...

  3. Continuous Water Quality Monitoring in the Sacramento-San Joaquin Delta to support Ecosystem Science

    Science.gov (United States)

    Downing, B. D.; Bergamaschi, B. A.; Pellerin, B. A.; Saraceno, J.; Sauer, M.; Kraus, T. E.; Burau, J. R.; Fujii, R.

    2013-12-01

    Characterizing habitat quality and nutrient availability to food webs is an essential step for understanding and predicting the success of pelagic organisms in the Sacramento-San Joaquin Delta (Delta). The difficulty is that water quality and nutrient supply changes continuously as tidal and wind-driven currents move new water parcels to and from comparatively static geomorphic settings. Understanding interactions between nutrient cycling, suspended sediment, and plankton dynamics with flow and tidal range relative to position in the estuary is critical to predicting and managing bottom up effects on aquatic habitat in the Delta. Historically, quantifying concentrations and loads in the Delta has relied on water quality data collected at monthly intervals. Current in situ optical sensors for nutrients, dissolved organic matter (DOM) and algal pigments (chlorophyll-A, phycocyanin) allow for real-time, high-frequency measurements on time scales of seconds, and extending up to years. Such data is essential for characterizing changes in water quality over short and long term temporal scales as well as over broader spatial scales. High frequency water quality data have been collected at key stations in the Delta since 2012. Sensors that continuously measure nitrate, DOM, algal pigments and turbidity have been co-located at pre-existing Delta flow monitoring stations. Data from the stations are telemetered to USGS data servers and are designed to run autonomously with a monthly service interval, where sensors are cleaned and checked against calibration standards. The autonomous system is verified against discrete samples taken monthly and intensively over periodic ebb to flood tidal cycles. Here we present examples of how coupled optical and acoustic data from the sensor network to improve our understanding of nutrient and DOM dynamics and fluxes. The data offer robust quantitative estimates of concentrations and constituent fluxes needed to investigate biogeochemical

  4. Estimating Lithium-Ion Battery State of Charge and Parameters Using a Continuous-Discrete Extended Kalman Filter

    Directory of Open Access Journals (Sweden)

    Yasser Diab

    2017-07-01

    Full Text Available A real-time determination of battery parameters is challenging because batteries are non-linear, time-varying systems. The transient behaviour of lithium-ion batteries is modelled by a Thevenin-equivalent circuit with two time constants characterising activation and concentration polarization. An experimental approach is proposed for directly determining battery parameters as a function of physical quantities. The model’s parameters are a function of the state of charge and of the discharge rate. These can be expressed by regression equations in the model to derive a continuous-discrete extended Kalman estimator of the state of charge and of other parameters. This technique is based on numerical integration of the ordinary differential equations to predict the state of the stochastic dynamic system and the corresponding error covariance matrix. Then a standard correction step of the extended Kalman filter (EKF is applied to increase the accuracy of estimated parameters. Simulations resulting from this proposed estimator model were compared with experimental results under a variety of operating scenarios—analysis of the results demonstrate the accuracy of the estimator for correctly identifying battery parameters.

  5. A virtual remote sensing observation network for continuous, near-real-time monitoring of atmospheric instability

    Science.gov (United States)

    Toporov, Maria; Löhnert, Ulrich; Potthast, Roland; Cimini, Domenico; De Angelis, Francesco

    2017-04-01

    Short-term forecasts of current high-resolution numerical weather prediction models still have large deficits in forecasting the exact temporal and spatial location of severe, locally influenced weather such as summer-time convective storms or cool season lifted stratus or ground fog. Often, the thermodynamic instability - especially in the boundary layer - plays an essential role in the evolution of weather events. While the thermodynamic state of the atmosphere is well measured close to the surface (i.e. 2 m) by in-situ sensors and in the upper troposphere by satellite sounders, the planetary boundary layer remains a largely under-sampled region of the atmosphere where only sporadic information from radiosondes or aircraft observations is available. The major objective of the presented DWD-funded project ARON (Extramural Research Programme) is to overcome this observational gap and to design an optimized network of ground based microwave radiometers (MWR) and compact Differential Absorption Lidars (DIAL) for a continuous, near-real-time monitoring of temperature and humidity in the atmospheric boundary layer in order to monitor thermodynamic (in)stability. Previous studies showed, that microwave profilers are well suited for continuously monitoring the temporal development of atmospheric stability (i.e. Cimini et al., 2015) before the initiation of deep convection, especially in the atmospheric boundary layer. However, the vertical resolution of microwave temperature profiles is best in the lowest kilometer above the surface, decreasing rapidly with increasing height. In addition, humidity profile retrievals typically cannot be resolved with more than two degrees of freedom for signal, resulting in a rather poor vertical resolution throughout the troposphere. Typical stability indices used to assess the potential of convection rely on temperature and humidity values not only in the region of the boundary layer but also in the layers above. Therefore, satellite

  6. Changes in soil parameters under continuous plastic mulching in strawberry cultivation

    Science.gov (United States)

    Muñoz, Katherine; Diehl, Dörte; Scopchanova, Sirma; Schaumann, Gabriele E.

    2016-04-01

    Plastic mulching (PM) is a widely used practice in modern agriculture because they generate conditions for optimal yield rates and quality. However, information about long-term effects of PC on soil quality parameters is scarce. The aim of this study is to compare the effect of three different mulching managements on soil quality parameters. Sampling and methodology: Three different managements were studied: Organic mulching (OM), 2-years PM and 4-years PM. Soil samples were collected from irrigated fields in 0-5, 5-10 and 10-30 cm depths and analyzed for water content (WC), pH, dissolved organic carbon (DOC), total soil carbon (Ctot) and cation exchange capacity (CECeff). Results and discussion: Mulching management has an influence on soil parameters. The magnitude of the effects is influenced by the type (organic agriculture practice vs. plastic mulching practice) and duration of the mulching. PM modified the water distribution through the soil column. WC values at the root zone were in average 10% higher compared to those measured at the topsoil. Under OM, the WC was lower than under PM. The pH was mainly influenced by the duration of the managements with slightly higher values after 4 than after 2-years PM. Under PM, aqueous extracts of the topsoil (0-5 cm depth) contained in average with 8.5±1.8 mg/L higher DOC than in 10-30 cm depth with 5.6±0.5 mg/L, which may indicate a mobilization of organic components in the upper layers. After 4-years PM, Ctot values were slightly higher than after 2-years PM and after OM. Surprisingly, after 4-years PM, CECeff values were with 138 - 157 mmolc/kg almost 2-fold higher than after 2-years PM and OM which had with 74 - 102 mmolc/kg comparable CECeff values. Long-term PM resulted in changes of soil pH and slightly increased Ctot which probably enhanced the CECeff of the soil. However, further investigations of the effect of PM on stability of soil organic matter and microbial community structure are needed.

  7. Hand disinfection in a neonatal intensive care unit: continuous electronic monitoring over a one-year period

    OpenAIRE

    Helder Onno K; van Goudoever Johannes B; Hop Wim C J; Brug Johannes; Kornelisse René F

    2012-01-01

    Abstract Background Good hand hygiene compliance is essential to prevent nosocomial infections in healthcare settings. Direct observation of hand hygiene compliance is the gold standard but is time consuming. An electronic dispenser with built-in wireless recording equipment allows continuous monitoring of its usage. The purpose of this study was to monitor the use of alcohol-based hand rub dispensers with a built-in electronic counter in a neonatal intensive care unit (NICU) setting and to d...

  8. Online Structural Health Monitoring and Parameter Estimation for Vibrating Active Cantilever Beams Using Low-Priced Microcontrollers

    Directory of Open Access Journals (Sweden)

    Gergely Takács

    2015-01-01

    Full Text Available This paper presents a structural health monitoring and parameter estimation system for vibrating active cantilever beams using low-cost embedded computing hardware. The actuator input and the measured position are used in an augmented nonlinear model to observe the dynamic states and parameters of the beam by the continuous-discrete extended Kalman filter (EKF. The presence of undesirable structural change is detected by variations of the first resonance estimate computed from the observed equivalent mass, stiffness, damping, and voltage-force conversion coefficients. A fault signal is generated upon its departure from a predetermined nominal tolerance band. The algorithm is implemented using automatically generated and deployed machine code on an electronics prototyping platform, featuring an economically feasible 8-bit microcontroller unit (MCU. The validation experiments demonstrate the viability of the proposed system to detect sudden or gradual mechanical changes in real-time, while the functionality on low-cost miniaturized hardware suggests a strong potential for mass-production and structural integration. The modest computing power of the microcontroller and automated code generation designates the proposed system only for very flexible structures, with a first dominant resonant frequency under 4 Hz; however, a code-optimized version certainly allows much stiffer structures or more complicated models on the same hardware.

  9. Drought monitoring over the Horn of Africa using remotely sensed evapotranspiration, soil moisture and vegetation parameters

    Science.gov (United States)

    Timmermans, J.; Gokmen, M.; Eden, U.; Abou Ali, M.; Vekerdy, Z.; Su, Z.

    2012-04-01

    The need to good drought monitoring and management for the Horn of Africa has never been greater. This ongoing drought is the largest in the past sixty years and is effecting the life of around 10 million people, according to the United Nations. The impact of drought is most apparent in food security and health. In addition secondary problems arise related to the drought such as large migration; more than 15000 Somalia have fled to neighboring countries to escape the problems caused by the drought. These problems will only grow in the future to larger areas due to increase in extreme weather patterns due to global climate change. Monitoring drought impact and managing the drought effects are therefore of critical importance. The impact of a drought is hard to characterize as drought depends on several parameters, like precipitation, land use, irrigation. Consequently the effects of the drought vary spatially and range from short-term to long-term. For this reason a drought event can be characterized into four categories: meteorological, agricultural, hydrological and socio-economical. In terms of food production the agricultural drought, or short term dryness near the surface layer, is most important. This drought is usually characterized by low soil moisture content in the root zone, decreased evapotranspiration, and changes in vegetation vigor. All of these parameters can be detected with good accuracy from space. The advantage of remote sensing in Drought monitoring is evident. Drought monitoring is usually performed using drought indices, like the Palmer Index (PDSI), Crop Moisture Index (CMI), Standard Precipitation Index (SPI). With the introduction of remote sensing several indices of these have shown great potential for large scale application. These indices however all incorporate precipitation as the main surface parameter neglecting the response of the surface to the dryness. More recently two agricultural drought indices, the EvapoTranspiration Deficit

  10. An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

    Science.gov (United States)

    Gao, F. G.; Jeevarajan, A. S.; Anderson, M. M.

    2002-01-01

    For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to

  11. Proposal of novel method of continuous monitoring of possible fuel failure of a pool-type reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, K. [Rikkyo University, Nishi-Ikebukuro, Toshima-ku, Tokyo (Japan). College of Science; Hayashi, S.A.; Matsura, T. [Rikkyo University, Nagasaka, Yokosuka (Japan). Institute for Atomic Energy

    1997-10-01

    During the course of studies on fuel failure detection, we have found that the bubbling of a gas such as nitrogen into a reactor coolant water effectively purges the dissolved fission rare gases ({sup 89}Kr, T{sub 1/2}=3.15 min, and {sup 138}Xe, T{sub 1/2}=14.08 min) and that the respective daughter nuclides ({sup 89}Rb, T{sub 1/2}=15.15 min and {sup 138}Cs, T{sub 1/2}=33.41 min) are detected in the washing water of the collected gas mixture. The detected activity depends on the time of standing between sampling and washing of the gas, and the dependence agreed well with the theoretical prediction from the consecutive radioactive decay for both pairs ({sup 89}Kr-{sup 89}Rb, and {sup 138}Xe-{sup 138}Cs). Based on these findings, we have recently constructed a semi-continuous fuel monitoring system, which consists of an automatic and intermittent gas sampler (1 litre bottles) and a bottle conveying unit. After standing for a definite time, bottled gas is shaken with a small amount of water, and the activity of the water is measured. This system operates satisfactorily, but the whole system involves several sophisticated steps so that is rather costly. Quite recently we have got an idea of a simpler, more economical, fully automated continuous system. The system consists in principle only of a large cylinder with packing materials just as in a fractional distiller. On the top of the cylinder there are an inlet of washing water and an outlet of the gas, and at the bottom there are an inlet of the collected gas from the coolant and an outlet of the washing water. The whole system can be operated fully automatically and continuously, with continuous feeding of bubbling gas into the reactor coolant. This has not yet been experimentally tested at present, and in this presentation, information about the setup parameters such as the flow rate of the bubbling gas, the volume of the cylinder and vacant space, the flow rate of the washing water, etc. are reported

  12. Determination of recharge fraction of injection water in combined abstraction-injection wells using continuous radon monitoring.

    Science.gov (United States)

    Lee, Kil Yong; Kim, Yong-Chul; Cho, Soo Young; Kim, Seong Yun; Yoon, Yoon Yeol; Koh, Dong Chan; Ha, Kyucheol; Ko, Kyung-Seok

    2016-12-01

    The recharge fractions of injection water in combined abstraction-injection wells (AIW) were determined using continuous radon monitoring and radon mass balance model. The recharge system consists of three combined abstraction-injection wells, an observation well, a collection tank, an injection tank, and tubing for heating and transferring used groundwater. Groundwater was abstracted from an AIW and sprayed on the water-curtain heating facility and then the used groundwater was injected into the same AIW well by the recharge system. Radon concentrations of fresh groundwater in the AIWs and of used groundwater in the injection tank were measured continuously using a continuous radon monitoring system. Radon concentrations of fresh groundwater in the AIWs and used groundwater in the injection tank were in the ranges of 10,830-13,530 Bq/m(3) and 1500-5600 Bq/m(3), respectively. A simple radon mass balance model was developed to estimate the recharge fraction of used groundwater in the AIWs. The recharge fraction in the 3 AIWs was in the range of 0.595-0.798. The time series recharge fraction could be obtained using the continuous radon monitoring system with a simple radon mass balance model. The results revealed that the radon mass balance model using continuous radon monitoring was effective for determining the time series recharge fractions in AIWs as well as for characterizing the recharge system. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. PROFESSIONAL CONTINUOUS FLASH GLUCOSE MONITORING WITH AMBULATORY GLUCOSE PROFILE REPORTING TO SUPPLEMENT A1C: RATIONALE AND PRACTICAL IMPLEMENTATION.

    Science.gov (United States)

    Hirsch, Irl B; Verderese, Carol A

    2017-08-17

    Recent consensus statements strongly advocate downloading and interpretation of continuous glucose data for diabetes management in patients with type 1 or type 2 diabetes. Supplementing periodic A1C testing with intermittent continuous glucose monitoring (CGM) using a standardized report form known as the ambulatory glucose profile (AGP) is an evolving standard of care. The rationale for this approach and its implementation with a recently approved novel monitoring technology are explored. Search of the medical literature, professional guidelines, and realworld evidence guided this introduction of an integrative practice framework that uses AGP in conjunction with intermittent continuous "flash" glucose monitoring (CFGM) as a supplement to A1C testing. The combination of intermittent continuous glucose pattern analysis, standardized glucose metrics, and a readily interpretable data report, as discussed in this review, has the potential to practically extend the recognized benefits of CGM to more patients, and clarify the relationship between A1C and average glucose levels in individual cases. Novel CFGM technologies portend greater use of continuous forms of glucose monitoring and wider adoption of AGP report analysis. Additional formal and empirical evidence is needed to more fully characterize best practice.

  14. Characterization of Industrial Coolant Fluids and Continuous Ageing Monitoring by Wireless Node-Enabled Fiber Optic Sensors

    DEFF Research Database (Denmark)

    Sachat, Alexandros El; Meristoudi, Anastasia; Markos, Christos

    2017-01-01

    Environmentally robust chemical sensors for monitoring industrial processes or infrastructures are lately becoming important devices in industry. Low complexity and wireless enabled characteristics can offer the required flexibility for sensor deployment in adaptable sensing networks for continuous...... of sensors allowed their integration in an autonomous wireless sensing node, thus enabling the future use of the demonstrated platform in wireless sensor networks for a variety of industrial and environmental monitoring applications.......-gel derived pH sensitive coatings. The performances of the developed sensors were characterized and compared, towards their coolants' ageing monitoring capability, proving their efficiency in such a demanding application scenario and harsh industrial environment. The operating characteristics of this type...

  15. Description of the behavior of an aquifer by using continuous radon monitoring in a thermal spa

    Energy Technology Data Exchange (ETDEWEB)

    Sainz, Carlos, E-mail: sainzc@unican.es; Rábago, Daniel; Fuente, Ismael; Celaya, Santiago; Quindós, Luis Santiago

    2016-02-01

    Radon ({sup 222}Rn) levels in air and water have been analyzed continuously for almost a year in Las Caldas de Besaya thermal spa, north Spain. Radon is a naturally occurring noble gas from the decay of radium ({sup 226}Ra) both constituents of radioactive uranium 238 series. It has been recognized as a lung carcinogen by the World Health Organization (WHO) and International Agency for Research on Cancer (IARC). Furthermore the Royal Decree R.D 1439/2010 of November, 2010 establishes the obligation to study occupational activities where workers and, where appropriate, members of the public are exposed to inhalation of radon in workplaces such as spas. Together with radon measures several physico-chemical parameters were obtained such as pH, redox potential, electrical conductivity and air and water temperature. The devices used for the study of the temporal evolution of radon concentration have been the RTM 2100, the Radon Scout and gamma spectrometry was complementarily used to determine the transfer factor of the silicone tubes in the experimental device. Radon concentrations obtained in water and air of the spa are high, with an average of 660 Bq/l and 2900 Bq/m{sup 3} respectively, where water is the main source of radon in the air. Radiation dose for workers and public was estimated from these levels of radon. The data showed that the thermal processes can control the behavior of radon which can be also influenced by various physical and chemical parameters such as pH and redox potential. - Highlights: • Radon in water is the major source of indoor air radon concentration in thermal facilities. • Radon in water has been used to characterize the origin of water used for treatments in a spa. • Preliminary dose assessment from radon exposure has been performed.

  16. Analysis of the non-Markov parameter in continuous-time signal processing.

    Science.gov (United States)

    Varghese, J J; Bellette, P A; Weegink, K J; Bradley, A P; Meehan, P A

    2014-02-01

    The use of statistical complexity metrics has yielded a number of successful methodologies to differentiate and identify signals from complex systems where the underlying dynamics cannot be calculated. The Mori-Zwanzig framework from statistical mechanics forms the basis for the generalized non-Markov parameter (NMP). The NMP has been used to successfully analyze signals in a diverse set of complex systems. In this paper we show that the Mori-Zwanzig framework masks an elegantly simple closed form of the first NMP, which, for C(1) smooth autocorrelation functions, is solely a function of the second moment (spread) and amplitude envelope of the measured power spectrum. We then show that the higher-order NMPs can be constructed in closed form in a modular fashion from the lower-order NMPs. These results provide an alternative, signal processing-based perspective to analyze the NMP, which does not require an understanding of the Mori-Zwanzig generating equations. We analyze the parametric sensitivity of the zero-frequency value of the first NMP, which has been used as a metric to discriminate between states in complex systems. Specifically, we develop closed-form expressions for three instructive systems: band-limited white noise, the output of white noise input to an idealized all-pole filter,f and a simple harmonic oscillator driven by white noise. Analysis of these systems shows a primary sensitivity to the decay rate of the tail of the power spectrum.

  17. Monitoring seismic velocity changes caused by the 2014 Northern Aegean earthquake using continuous ambient noise records

    Science.gov (United States)

    Evangelidis, Christos; Daskalakis, Emmanouil; Tsogka, Chrysoula

    2016-04-01

    The 24 May 2014 Northern Aegean earthquake (6.9 Mw), an event on the Northern Aegean Trough (NAT), ruptured on two different fault segments with a total ruptured length of ~100 km. For the second delayed segment, rupture propagated eastward from the hypocenter for ˜65 km with a supershear velocity (5.5 km/s). Low-aftershock seismicity on the supershear segment implies a simple and linear fault geometry there. An effort to monitor temporal seismic velocity changes across the ruptured area of the Northern Aegean earthquake is underway. In recent years, neighboring seismic broadband stations near active faults have been successfully used to detect such changes. The crosscorrelation functions (CCF) of ambient noise records between stations yields the corresponding traveltimes for those inter-station paths. Moreover, the auto-correlation functions (ACF) at each station produce the seismic responce for a coincident source and receiver position. Possible temporal changes of the measured traveltimes from CCFs and ACFs correspond to seismic velocity changes. Initially, we investigate the characteristics and sources of the ambient seismic noise as recorded at permanent seismic stations installed around NAT at the surrounding islands and in mainland Greece and Turkey. The microseismic noise levels show a clear seasonal variation at all stations. The noise levels across the double frequency band (DF; period range 4-8 s) reflect the local sea-weather conditions within a range of a few hundred kilometers. Three years of continuous seismic records framing the main shock have been analysed from ~15 stations within a radius of 100 km from the epicentre. We observe a clear decrease of seismic velocities most likely corresponding to the co-seismic shaking. The spatial variation of this velocity drop is imaged from all inter-station paths that correspond to CCF measurements and for station sites that correspond to ACF measurements. Thus, we explore a possible correlation between co

  18. Continuous online monitoring of ionic dialysance allows modification of delivered hemodialysis treatment time.

    Science.gov (United States)

    Chesterton, Lindsay J; Priestman, William S; Lambie, Stewart H; Fielding, Catherine A; Taal, Maarten W; Fluck, Richard J; McIntyre, Christopher W

    2006-10-01

    Considerable intrinsic intrapatient variability influences the actual delivery of Kt/V. The aim of this study is to examine the feasibility of using continuous online assessment of ionic dialysance measurements (Kt/V(ID)) to allow dialysis sessions to be altered on an individual basis. Ten well-established chronic hemodialysis (HD) patients without significant residual renal function were studied (mean age 65+/-4.3 [38-81] years, mean length of time on dialysis 66+/-18 [14-189] months). These patients had all been receiving thrice-weekly 4-hr dialysis using Integra dialysis monitors. Dialysis monitors were equipped with Diascan modules permitting measurement of Kt/V(ID). Predicted treatment time required to achieve a Kt/V(ID) > or = 1.1 (equivalent to a urea-based method of 1.2) was calculated from the delivered Kt/V(ID) at 60 and 120 min. Treatment time was reprogrammed at 2 hr (ensuring all planned ultrafiltration would be accommodated into the new modified session duration). Owing to practical issues, and to avoid excessively short dialysis times, these changes were censored at no more than+/-10% of the usual 240-min treatment time (210-265 min). Data were collected from a total of 50 dialysis sessions. Almost all sessions (47/50) required modification of the standard treatment time: 13/50 sessions were lengthened and 34/50 shortened (mean length of session 232.2+/-2.5 [210-265] min). A Kt/V(ID) of > or = 1.1 was achieved in 39/50 sessions. The difference in mean urea-based Kt/V poststudy (1.3+/-0.05 [1.1-1.6]) and mean achieved Kt/V(ID) (1.16+/-0.02 [0.7-1.37]) was significant (p = 0.002). The use of individualized variable dialysis treatment time using online ionic dialysance measurements of Kt/V(ID) appears both practicable and effective at ensuring consistently delivered adequate dialysis.

  19. Continuation of long-term global SO2 pollution monitoring from OMI to OMPS

    Science.gov (United States)

    Zhang, Y.; Li, C.; Krotkov, N. A.; Joiner, J.

    2016-12-01

    In the past 12+ years, Ozone Monitoring Instrument (OMI) on board NASA EOS Aura satellite has pioneered the first high-resolution global SO2 pollution monitoring, which enabled new studies of atmospheric chemistry and applications for air quality management. Such long-term SO2 record will be continued with other satellite instruments, i.e., the Ozone Mapping and Profiler Suite (OMPS) Nadir Mapper on board NASA-NOAA Suomi National Polar-orbiting Partnership (S-NPP) satellite and the follow up JPSS series satellites. In this presentation, we demonstrate the first comparison between OMI and OMPS SO2 retrievals from the OMI operational SO2 algorithm, which is our state-of-the-art principal component analysis (PCA) approach. The PCA technique does not use any sort of "soft calibration" corrections required in concurrent satellite SO2 algorithms and enables seamless merging of different satellite datasets. We demonstrate a very good consistency of the retrievals from OMI and OMPS. Four full years of OMI and OMPS SO2 retrievals during 2012-2015 have been analyzed over some of the world's most polluted regions: eastern China, Mexico, and South Africa. In general, the comparisons show high correlations (r =0.79-0.96) of SO2 mass between the two instruments on a daily basis and less than unity regression slopes (0.76-0.97) indicating slightly lower OMPS SO2 mass as compared with OMI. The annual averaged SO2 loading difference between OMI and OMPS is negligible (instruments also show generally good agreement in terms of the daily spatial distribution in SO2. For example, over the Mexico region for 82% of the days, the two instruments have a spatial correlation coefficient of 0.6 or better. Such consistent retrievals were achieved without any explicit adjustment to OMI or OMPS radiance data. We will further improve the retrieval agreement in the next versions of the OMI and OMPS retrievals by applying a more comprehensive Jacobian lookup table that properly accounts for

  20. Stress-induced traveltime variations at SAFOD revealed by continuous cross-well active source monitoring

    Science.gov (United States)

    Yang, C.; Niu, F.; Daley, T. M.; Taira, T.

    2016-12-01

    The time-varying stress/strain field at seismogenic depths is arguable the single most important property controlling the sequencing and nucleation of seismic events. The measurement of stress, however, is notoriously difficult, particularly at seismogenic depths. Seismic imaging, in principle, has the capability to provide this critical depth component. Numerous laboratory studies over the last few decades have shown that the elastic properties of crustal rocks clearly exhibit stress dependence. Such dependence is attributed to the opening/closing of fluid-filled cracks in response to changes in the stress normal to the crack surface. Temporal changes in stress are thus, in principle, measurable through seismic imaging of changes in elastic properties, such as seismic velocity field. We have been conducting continuous cross-well active source experiments utilizing the SAFOD (San Andreas Fault Observatory at Depth) pilot and main holes to develop a seismic stress meter to monitor the subsurface stress field by exploring the velocity-stress sensitivity. In a two-month period in 2005-2006, we found a 0.3% change in the average S-wave velocity, which shows a good correlation with barometric pressure, corresponding to a stress sensitivity of 2.4x10-7Pa-1. We also observed two large excursions in the delay time measurement, corresponding to 0.55% and 0.15% decreases of seismic velocity, that are coincident with two earthquakes that are among those predicted to produce the largest coseismic stress changes. The two excursions started approximately 10 and 2 hours before the events, respectively, suggesting that they may be related to pre-rupture stress induced changes in crack properties, as observed in early laboratory studies. We repeated the experiment in early 2010 with a slightly different experiment configuration, and collected 40-days data. The new data confirmed the negative correlation between traveltime and barometric pressure. The estimated stress sensitivity is

  1. An Experimental Trial Exploring the Impact of Continuous Transdermal Alcohol Monitoring upon Alcohol Consumption in a Cohort of Male Students

    OpenAIRE

    2013-01-01

    Objective: To examine the impact of continuous transdermal alcohol monitoring upon alcohol consumption in male students at a Scottish university.\\ud \\ud Method: Using a within-subject mixed-methods design, 60 male university students were randomly allocated into three experimental conditions using AUDIT score stratified sampling. Participants in Conditions A and B were asked not to consume alcohol for a 14-day period, with those in Condition A additionally being required to wear a continuous ...

  2. Use of Continuous Monitors and Autosamplers to Predict Unmeasured Water-Quality Constituents in Tributaries of the Tualatin River, Oregon

    Science.gov (United States)

    Anderson, Chauncey W.; Rounds, Stewart A.

    2010-01-01

    Management of water quality in streams of the United States is becoming increasingly complex as regulators seek to control aquatic pollution and ecological problems through Total Maximum Daily Load programs that target reductions in the concentrations of certain constituents. Sediment, nutrients, and bacteria, for example, are constituents that regulators target for reduction nationally and in the Tualatin River basin, Oregon. These constituents require laboratory analysis of discrete samples for definitive determinations of concentrations in streams. Recent technological advances in the nearly continuous, in situ monitoring of related water-quality parameters has fostered the use of these parameters as surrogates for the labor intensive, laboratory-analyzed constituents. Although these correlative techniques have been successful in large rivers, it was unclear whether they could be applied successfully in tributaries of the Tualatin River, primarily because these streams tend to be small, have rapid hydrologic response to rainfall and high streamflow variability, and may contain unique sources of sediment, nutrients, and bacteria. This report evaluates the feasibility of developing correlative regression models for predicting dependent variables (concentrations of total suspended solids, total phosphorus, and Escherichia coli bacteria) in two Tualatin River basin streams: one draining highly urbanized land (Fanno Creek near Durham, Oregon) and one draining rural agricultural land (Dairy Creek at Highway 8 near Hillsboro, Oregon), during 2002-04. An important difference between these two streams is their response to storm runoff; Fanno Creek has a relatively rapid response due to extensive upstream impervious areas and Dairy Creek has a relatively slow response because of the large amount of undeveloped upstream land. Four other stream sites also were evaluated, but in less detail. Potential explanatory variables included continuously monitored streamflow

  3. Universal computer vision system for monitoring the main parameters of wind turbines

    Directory of Open Access Journals (Sweden)

    Korzhavin Sergey

    2016-01-01

    Full Text Available The article presents universal autonomous system of computer vision to monitor the operation of wind turbines. The proposed system allows to estimate the rotational speed and the relative position deviation of the wind turbine. We present a universal method for determining the rotation of wind turbines of various shapes and structures. All obtained data are saved in the database. The presented method was tested at the Territory of Non-traditional Renewable Energy Sources of Ural Federal University Experimental wind turbines is produced by “Scientific and Production Association of automatics named after academician N.A. Semikhatov”. Results show the efficiency of the proposed system and the ability to determine main parameters such as the rotational speed, accuracy and quickness of orientation. The proposed solution is to assume that, in most cases a rotating and central parts of the wind turbine can be allocated different color. The color change of wind blade should not affect the system performance.

  4. Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids

    Science.gov (United States)

    Coleman, Max; Kudryavtsev, Vitaly A.; Spooner, Neil J.; Fung, Cora; Gluyas, John

    2013-01-01

    Muon tomography has been used to seek hidden chambers in Egyptian pyramids and image subsurface features in volcanoes. It seemed likely that it could be used to image injected, supercritical carbon dioxide as it is emplaced in porous geological structures being used for carbon sequestration, and also to check on subsequent leakage. It should work equally well in any other application where there are two fluids of different densities, such as water and oil, or carbon dioxide and heavy oil in oil reservoirs. Continuous monitoring of movement of oil and/or flood fluid during enhanced oil recovery activities for managing injection is important for economic reasons. Checking on leakage for geological carbon storage is essential both for safety and for economic purposes. Current technology (for example, repeat 3D seismic surveys) is expensive and episodic. Muons are generated by high- energy cosmic rays resulting from supernova explosions, and interact with gas molecules in the atmosphere. This innovation has produced a theoretical model of muon attenuation in the thickness of rock above and within a typical sandstone reservoir at a depth of between 1.00 and 1.25 km. Because this first simulation was focused on carbon sequestration, the innovators chose depths sufficient for the pressure there to ensure that the carbon dioxide would be supercritical. This innovation demonstrates for the first time the feasibility of using the natural cosmic-ray muon flux to generate continuous tomographic images of carbon dioxide in a storage site. The muon flux is attenuated to an extent dependent on, amongst other things, the density of the materials through which it passes. The density of supercritical carbon dioxide is only three quarters that of the brine in the reservoir that it displaces. The first realistic simulations indicate that changes as small as 0.4% in the storage site bulk density could be detected (equivalent to 7% of the porosity, in this specific case). The initial

  5. Continuous multichannel monitoring of cave air carbon dioxide using a pumped non-dispersive infrared analyser

    Science.gov (United States)

    Mattey, D.

    2012-04-01

    The concentration of CO2 in cave air is one of the main controls on the rate of degassing of dripwater and on the kinetics of calcite precipitation forming speleothem deposits. Measurements of cave air CO2reveal great complexity in the spatial distribution among interconnected cave chambers and temporal changes on synoptic to seasonal time scales. The rock of Gibraltar hosts a large number of caves distributed over a 300 meter range in altitude and monthly sampling and analysis of air and water combined with continuous logging of temperature, humidity and drip discharge rates since 2004 reveals the importance of density-driven seasonal ventilation which drives large-scale advection of CO2-rich air though the cave systems. Since 2008 we have deployed automatic CO2 monitoring systems that regularly sample cave air from up to 8 locations distributed laterally and vertically in St Michaels Cave located near the top of the rock at 275m asl and Ragged Staff Cave located in the heart of the rock near sea level. The logging system is controlled by a Campbell Scientific CR1000 programmable datalogger which controls an 8 port manifold connected to sampling lines leading to different parts of the cave over a distance of up to 250 meters. The manifold is pumped at a rate of 5l per minute drawing air through 6mm or 8mm id polythene tubing via a 1m Nafion loop to reduce humidity to local ambient conditions. The outlet of the primary pump leads to an open split which is sampled by a second low flow pump which delivers air at 100ml/minute to a Licor 820 CO2 analyser. The software selects the port to be sampled, flushes the line for 2 minutes and CO2 analysed as a set of 5 measurements averaged over 10 second intervals. The system then switches to the next port and when complete shuts down to conserve power after using 20 watts over a 30 minute period of analysis. In the absence of local mains power (eg from the show cave lighting system) two 12v car batteries will power the system

  6. Impact of Polysomnographic Parameters on Continuous Positive Airway Pressure in Patient with Obstructive Sleep Apnea in 2012

    Directory of Open Access Journals (Sweden)

    Abolfazl Mozafari

    2014-06-01

    Full Text Available Background & objectives : O bstructive sleep apnea is a preventable and prevalent major health hazard with serious health consequences including excessive daytime sleepiness, cognitive disturbances, depression, cardiovascular diseases and hypertension. Obstructive sleep apnea is a disorder affecting 2 to 4% of the adult population. The continuous positive airway pressur e (CPAP i s the most efficacious therapy and is often the first option for these patients. The pressure titration during laboratory polysomnography is required for treatment by CPAP.   Methods: The patients with obstructive sleep apnea requiring continuous positive airway pressure treatment were selected . CPAP titration was done according to American Academy of Sleep Medicine protocol. Comparison among continuous positive airway pressure with polysomnographic parameters was performed and analyzed with Pearson correlation coefficient. For analysis of qualitative parameters, we used chi-square and then checked with SPSS version 18 software.   Results: From 125 patients with obstructive sleep apnea, there were 112 cases with inclusion criteria. Mean age of participants was 55.07 ± 12, male frequency was 59.2%, apnea hypopnea index was 43.62 and mean continuous positive airway pressure was 12.50 . There was significant relationship among the pressure of continuous positive airway pressure with apnea hypopnea index (P=0.028, arousal index (P=0.011, body mass index (P=0.041 and O2 desaturation index (P=0.022, although age was not significantly related.   Conclusion: In accordance to this data, we found out a prediction equation for optimal CPAP in our patients

  7. An outbreak of multidrug-resistant Serratia marcescens: The importance of continuous monitoring of nosocomial infections

    Directory of Open Access Journals (Sweden)

    Maida Šiširak

    2013-05-01

    Full Text Available Objectives. Serratia marcescens is a well-established as a nosocomial pathogen, resulting in considerable morbidity and mortality in immunocompromised patients. The aim of this study was to investigate an outbreak of Serratia marcescens at the Orthopaedic Clinic of the Clinical Center University of Sarajevo. Methods. A total of 96 strains from 79 patients were isolated. The isolates were identified by conventional methods. Susceptibility testing was performed by the discdiffusion method following CLSI guidelines. Results were confirmed by VITEC-2 Compact. Results. From January to December 2010, 96 strains from 79 patients were isolated at the Orthopaedic Clinic of the Clinical Center, University of Sarajevo.The strains were isolated from wound swabs, blood cultures and cerebrospinal fluid. The strains were identifed using current phenotypic methods as Serratia marcescens with identical biochemical characteristics and antibiotic susceptibility patterns. All strains were susceptible to imipenem, meropenem, amikacin, ciprofloxacin, levofloxacin and piperacillin/tazobactam. The infection control team was alerted and after investigation they discovered the same phenotype of Serratia marcescens in the anaesthetic vials used in procedures. This outbreak was extremely difficult to terminate, even with cohorting of patients, sterilisation of equipment, reinforcement of handwashing and deep-cleaning of facilities. The implementation of new control measures terminated the outbreak in February 2011. Conclusion. Continuous monitoring of nosocomial infections is indispensable. Phenotypic characterization of the isolates is useful for studying the relationship of microbial pathogens. The relationship of one clinical isolate to another during an outbreak is important in motivating the search for a common source or mode of transmission.

  8. Diagnosis of digestive functional disease by the statistics of continuous monitoring of esophageal acidity

    Science.gov (United States)

    Rivera Landa, Rogelio; Cardenas Cardenas, Eduardo; Fossion, Ruben; Pérez Zepeda, Mario Ulises

    2014-11-01

    Technological advances in the last few decennia allow the monitoring of many physiological observables in a continuous way, which in physics is called a "time series". The best studied physiological time series is that of the heart rhythm, which can be derived from an electrocardiogram (ECG). Studies have shown that a healthy heart is characterized by a complex time series and high heart rate variability (HRV). In adverse conditions, the cardiac time series degenerates towards randomness (as seen in, e.g., fibrillation) or rigidity (as seen in, e.g., ageing), both corresponding to a loss of HRV as described by, e.g., Golberger et. al [1]. Cardiac and digestive rhythms are regulated by the autonomous nervous system (ANS), that consists of two antagonistic branches, the orthosympathetic branch (ONS) that accelerates the cardiac rhythm but decelerates the digestive system, and the parasympathetic brand (PNS) that works in the opposite way. Because of this reason, one might expect that the statistics of gastro-esophageal time series, as described by Gardner et. al. [2,3], reflects the health state of the digestive system in a similar way as HRV in the cardiac case, described by Minocha et. al. In the present project, we apply statistical methods derived from HRV analysis to time series of esophageal acidity (24h pHmetry). The study is realized on data from a large patient population from the Instituto Nacional de Ciencias Médicas y Nutrición Salvador Zubirán. Our focus is on patients with functional disease (symptoms but no anatomical damage). We find that traditional statistical approaches (e.g. Fourier spectral analysis) are unable to distinguish between different degenerations of the digestive system, such as gastric esophageal reflux disease (GERD) or functional gastrointestinal disorder (FGID).

  9. Continuous ECG monitoring for tracking down atrial fibrillation after stroke: Holter or automated analysis strategy?

    Science.gov (United States)

    Suissa, Laurent; Lachaud, Sylvain; Mahagne, Marie-Hélène

    2014-01-01

    Tracking down atrial fibrillation (AF) in the stroke unit is a relevant challenge for the prevention of recurrent AF-related stroke. The optimal terms of use of continuous ECG monitoring (CEM) are unknown. We compared 24-hour routine Holter ECG with two different CEM analysis strategies for AF detection. We prospectively enrolled consecutive ischemic stroke patients. All AF-naïve patients received CEM during hospitalization. Two methods for reading CEM data were compared: manual analysis using the Holter function (hCEM) and semiautomated analysis using software (aCEM). The McNemar test was used to compare AF detection rates. Of the 362 patients included, 58 (16.0%) were non-AF-naïve patients and 304 were AF-naïve patients. AF-Naïve patients underwent CEM with a median duration of 5.3 days (3.4-9.7). We detected 22 new AF cases (7.2%) with first-24-hour hCEM, 31 (10.2%) with aCEM, and 42 (13.8%) with hCEM. hCEM and aCEM both significantly increased the AF detection rate compared to first-24-hour hCEM. hCEM detected more new AF cases than aCEM (+3.6%, p = 0.003). In stroke patients, early and prolonged aCEM and hCEM both increase the AF detection rate compared to first-24-hour hCEM. hCEM gives the best AF detection rate. We suggest that in aCEM, detection based only on the ventricular rhythm analysis explains its lower specificity and sensitivity. © 2014 S. Karger AG, Basel.

  10. A Continuous Automated Vault Inventory System (CAVIS) for accountability monitoring of stored nuclear materials

    Energy Technology Data Exchange (ETDEWEB)

    Pickett, C.A.; Barham, M.A.; Gafford, T.A.; Hutchinson, D.P.; Jordan, J.K.; Maxey, L.C.; Moran, B.W.; Muhs, J.; Nodine, R.; Simpson, M.L. [and others

    1994-12-08

    Nearly all facilities that store hazardous (radioactive or non-radioactive) materials must comply with prevailing federal, state, and local laws. These laws usually have components that require periodic physical inspections to insure that all materials remain safely and securely stored. The inspections are generally labor intensive, slow, put personnel at risk, and only find anomalies after they have occurred. The system described in this paper was developed for monitoring stored nuclear materials resulting from weapons dismantlement, but its applications extend to any storage facility that meets the above criteria. The traditional special nuclear material (SNM) accountability programs, that are currently used within most of the Department of Energy (DOE) complex, require the physical entry of highly trained personnel into SNM storage vaults. This imposes the need for additional security measures, which typically mandate that extra security personnel be present while SNM inventories are performed. These requirements increase labor costs and put additional personnel at risk to radiation exposure. In some cases, individuals have received radiation exposure equivalent to the annual maximum during just one inventory verification. With increasing overhead costs, the current system is rapidly becoming too expensive to operate, the need for an automated method of inventory verification is evident. The Continuous Automated Vault Inventory System (CAVIS) described in this paper was designed and prototyped as a low cost, highly reliable, and user friendly system that is capable of providing, real-time weight, gamma. and neutron energy confirmation from each item stored in a SNM vault. This paper describes the sensor technologies, the CAVIS prototype system (built at Y- 12 for highly enriched uranium storage), the technical requirements that must be achieved to assure successful implementation, and descriptions of sensor technologies needed for a plutonium facility.

  11. Feasibility of adjacent insulin infusion and continuous glucose monitoring via the Medtronic Combo-Set.

    Science.gov (United States)

    O'Neal, David N; Adhya, Sumona; Jenkins, Alicia; Ward, Glenn; Welsh, John B; Voskanyan, Gayane

    2013-03-01

    Subcutaneously infused insulin may interfere with the function of nearby glucose-sensing electrodes and vice versa. The prototype of the Combo-Set device (Medtronic) incorporates a subcutaneous insulin delivery catheter and continuous glucose monitoring (CGM) sensor assembled on the same platform and separated by 11 mm. We aim to evaluate Combo-Set's insulin delivery and glucose-sensing functions. Ten subjects with type 1 diabetes wore a Combo-Set and a Sof-Sensor inserted subcutaneously in contralateral abdominal areas connected to iPro recorders (Medtronic) for 53.25 ± 0.75 h (mean ± standard deviation). The Combo-Set delivered insulin diluent except during meal tests on days 1 and 3 when insulin lispro was delivered as a meal bolus and postmeal basal. Venous plasma samples were collected at the following time points from meal start: 0, 30, 60, 120, and 180 min for insulin measurements. The accuracy of the Combo-Set sensors was evaluated and compared with that of the Sof-Sensor, with each referenced against capillary glucose values (Contour Link Meter, Bayer). Accuracy of the Combo-Set sensor was comparable to that of the Sof-Sensor. Clarke error grid analysis showed that 97% of Combo-Set and 93% of Sof-Sensor values were in the A+B regions (p = .20, not significant). The Combo-Set showed the expected postbolus peak insulin time (67 ± 9 min, mean ± standard error). One "no delivery" alarm occurred during the 21 patient days of use. A device providing for simultaneous adjacent placement of an insulin infusion catheter and a CGM sensor is feasible and functions within acceptable limits. The low "no delivery" alarm rate was similar to that of other infusion sets. © 2013 Diabetes Technology Society.

  12. Simulation of Daily Snapshot Rhythm Monitoring to Identify Atrial Fibrillation in Continuously Monitored Patients with Stroke Risk Factors.

    Directory of Open Access Journals (Sweden)

    Yuichiro Yano

    Full Text Available New technologies are diffusing into medical practice swiftly. Hand-held devices such as smartphones can record short-duration (e.g., 1-minute ECGs, but their effectiveness in identifying patients with paroxysmal atrial fibrillation (AF is unknown.We used data from the TRENDS study, which included 370 patients (mean age 71 years, 71% men, CHADS2 score≥1 point: mean 2.3 points who had no documentation of atrial tachycardia (AT/AF or antiarrhythmic or anticoagulant drug use at baseline. All were subsequently newly diagnosed with AT/AF by a cardiac implantable electronic device (CIED over one year of follow-up. Using a computer simulation approach (5,000 repetitions, we estimated the detection rate for paroxysmal AT/AF via daily snapshot ECG monitoring over various periods, with the probability of detection equal to the percent AT/AF burden on each day.The estimated AT/AF detection rates with snapshot monitoring periods of 14, 28, 56, 112, and 365 days were 10%, 15%, 21%, 28%, and 50% respectively. The detection rate over 365 days of monitoring was higher in those with CHADS2 scores ≥2 than in those with CHADS2 scores of 1 (53% vs. 38%, and was higher in those with AT/AF burden ≥0.044 hours/day compared to those with AT/AF burden <0.044 hours/day (91% vs. 14%; both P<0.05.Daily snapshot ECG monitoring over 365 days detects half of patients who developed AT/AF as detected by CIED, and shorter intervals of monitoring detected fewer AT/AF patients. The detection rate was associated with individual CHADS2 score and AT/AF burden.ClinicalTrials.gov NCT00279981.

  13. Effect of Structure Parameters on Power and Magnetic Field in Electromagnetic Soft-Contact Continuous Casting System

    Institute of Scientific and Technical Information of China (English)

    DENG An-yuan; WANG En-gang; HE Ji-cheng

    2008-01-01

    To design a power source system and mold for electromagnetic soft-contact continuous casting process and to theoretically estimate the heat losses from the charges and the system power, the effect of structure parameters on system power and magnetic flux density distribution was calculated using finite element method. The results show that as for electromagnetic soft-contact continuous casting system with partial-segment type mold, the power consumption is much more than that with a full-segment type mold; about 62% of electric power is dissipated in the mold, and the effective acting range of magnetic field is relatively narrow. Optimizing mold structure is a crucial measure of remarkably reducing mold power consumption and saving electric energy. Increasing slit number, width, and length can remarkably increase the magnetic flux density in the mold and can reduce the electric energy consumption. Among structure parameters, slit number and slit width are relatively more effective to reduce energy consumption. For a round billet electromagnetic continuous casting system with diameter of 178 mm, the reasonable slit number, width, and length are about 24-32, 0.5-1.0 mm, and 160 mm, respectively.

  14. The safety parameters monitoring system for the coal mine based on CAN bus communication and intelligent data acquisition

    Institute of Scientific and Technical Information of China (English)

    Bin Guangfu; Chu Wangwen; Balbir S.Dhillon; He Wenbiao

    2008-01-01

    In this paper,a monitoring and controlling system for the safety in production and environmental parameters of a small and medium-sized coal mine has been developed after analyzing the current domestic coal production and securi-ty conditions.The client computer can convert the analog signal about the safety in production and environmental param-eters detected from the monitoring terminal into digital signal,and then,send the signal to the coal mine safety monito-ring centre.This information can be analyzed,judged,and diagnosed by the monitoring-management-controUing soft-ware for helping the manager and technical workers to control the actual underground production and security situations.The system has many advantages including high reliability,better performance of real-time monitoring,faster data com-municating and good practicability,and it can effectively prevent the occurrence of safety incidents in coal mines.

  15. Surrogate parameters for rapid monitoring of contaminant removal for activated sludge treatment plants for para rubber and seafood industries in Southern Thailand

    Directory of Open Access Journals (Sweden)

    Panalee Chevakidagarn

    2005-03-01

    Full Text Available This study aimed at using surrogate parameters for rapid monitoring of contaminant removed of activated sludge treatment plant for para rubber and seafood industries in Southern Thailand. Wastewaters from these industries contain high organic concentrations and chemicals. The activated sludge process (AS is usually applied as a treatment process. However, plant operators generally lack the understanding and means to control the treatment plants because of a continuous monitoring system is not employed and the monitoring parameters are time consuming. UV absorbency at various wavelengths was used in this study as a surrogate parameters, for predicting the removal capacity of each plant. COD, BOD, suspended solids and nitrate-nitrogen concentrations could be estimated reliably without being time consuming. The results showed that UV absorbency at 220 nm can be used as a parameter to predict nitrate-nitrogen concentrations which less than 15 mg/L. That at 550 nm is for predicting suspended solids concentration and that at 260 nm is for COD predict.

  16. Continuous Medication Monitoring (CoMM): A foundational model to support the clinical work of community pharmacists.

    Science.gov (United States)

    Goedken, Amber M; Butler, Christine M; McDonough, Randal P; Deninger, Michael J; Doucette, William R

    2017-01-02

    Under the Continuous Medication Monitoring (CoMM) approach, community pharmacists prevent, identify, resolve, and document drug therapy problems during the dispensing process. To describe the patients receiving CoMM interventions and the pattern of delivery of CoMM interventions. Pharmacy dispensing and clinical records were reviewed for patients filling at least one prescription and receiving at least one continuous medication monitoring intervention at a community pharmacy from April 2014 through March 2015. The proportion of patients receiving an intervention type and the number of interventions per patient were computed. Nearly 2500 patients received 16,986 continuous medication monitoring interventions over the year. The average age of the patients receiving the interventions was 59.1 years, and they filled an average of 8.0 unique medications. An average of 6.8 interventions was delivered to each patient. About half (49.7%) of interventions addressed drug therapy problems. The pharmacists delivered 3.0 patient counseling and education and 3.4 drug therapy problem interventions per patient on average. There are many opportunities to improve patients' medication use that can be identified and addressed under a Continuous Medication Monitoring model. Movement to this model of practice is desirable, but changes are needed to facilitate the shift. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. 40 CFR Appendix D to Part 52 - Determination of Sulfur Dioxide Emissions From Stationary Sources by Continuous Monitors

    Science.gov (United States)

    2010-07-01

    ....3Accuracy (Relative). The degree of correctness with which the measurement system yields the value of gas... in terms of error which is the difference between the paired concentration measurements expressed as... Stationary Sources by Continuous Monitors 1. Definitions. 1.1Concentration Measurement System. The...

  18. The effects of real-time continuous glucose monitoring on oxidative stress and mortality in critically ill patients

    Institute of Scientific and Technical Information of China (English)

    钱武强

    2013-01-01

    Objective To evaluate the effects of real-time continuous glucose monitoring(RT-CGM) system on oxidative stress and mortality in critically ill patients and to explore the correlation between glucose index,oxidative stress and mortality. Methods 123 selected cases of

  19. Incidence of paroxysmal atrial tachycardias in patients treated with cardiac resynchronization therapy and continuously monitored by device diagnostics

    NARCIS (Netherlands)

    Leclercq, C.; Padeletti, L.; Cihak, R.; Ritter, P.; Milasinovic, G.; Gras, D.; Paul, V.; Van Gelder, I. C.; Stellbrink, C.; Rieger, G.; Corbucci, G.; Albers, B.; Daubert, J. C.

    2010-01-01

    Little is known about the incidence of paroxysmal atrial tachycardias (PAT) in patients with heart failure (HF). The availability of cardiac resynchronization therapy (CRT) devices with extended diagnostics for AT enables continuous monitoring of PAT episodes. The aim of the study was to assess the

  20. Monitoring colony phenology using within-day variability in continuous weight and temperature of honey bee hives

    Science.gov (United States)

    Continuous weight and temperature data were collected for honey bee hives in two locations in Arizona, and those data were evaluated with respect to separate measurements of hive phenology to develop methods for monitoring hives non-invasively. Both the weight and temperature data were divided into ...