  1. Nocturnal continuous glucose monitoring

    DEFF Research Database (Denmark)

    Bay, Christiane; Kristensen, Peter Lommer; Pedersen-Bjergaard, Ulrik

    2013-01-01

    Abstract Background: A reliable method to detect biochemical nocturnal hypoglycemia is highly needed, especially in patients with recurrent severe hypoglycemia. We evaluated reliability of nocturnal continuous glucose monitoring (CGM) in patients with type 1 diabetes at high risk of severe...

  2. Comparison of the clinical information provided by the FreeStyle Navigator continuous interstitial glucose monitor versus traditional blood glucose readings.

    Science.gov (United States)

    McGarraugh, Geoffrey V; Clarke, William L; Kovatchev, Boris P

    2010-05-01

    The purpose of the analysis was to compare the clinical utility of data from traditional self-monitoring of blood glucose (SMBG) to that of continuous glucose monitoring (CGM). A clinical study of the clinical accuracy of the FreeStyle Navigator CGM System (Abbott Diabetes Care, Alameda, CA), which includes SMBG capabilities, was conducted by comparison to the YSI blood glucose analyzer (YSI Inc., Yellow Springs, OH) using 58 subjects with type 1 diabetes. The Continuous Glucose-Error Grid Analysis (CG-EGA) was used as the analytical tool. Using CG-EGA, the "clinically accurate," "benign errors," and "clinical errors" were 86.8%, 8.7%, and 4.5% for SMBG and 92.7%, 3.7%, and 3.6% for CGM, respectively. If blood glucose is viewed as a process in time, SMBG would provide accurate information about this process 86.8% of the time, whereas CGM would provide accurate information about this process 92.7% of the time (P glucose values than CGM, control of blood glucose involves a system in flux, and CGM provides more detailed insight into the dynamics of that system. In the normal and elevated glucose ranges, the additional information about the direction and rate of glucose change provided by the FreeStyle Navigator CGM System increases the ability to make correct clinical decisions when compared to episodic SMBG tests.

  3. Accuracy of flash glucose monitoring and continuous glucose monitoring technologies: Implications for clinical practice.

    Science.gov (United States)

    Ajjan, Ramzi A; Cummings, Michael H; Jennings, Peter; Leelarathna, Lalantha; Rayman, Gerry; Wilmot, Emma G

    2018-02-01

    Continuous glucose monitoring and flash glucose monitoring technologies measure glucose in the interstitial fluid and are increasingly used in diabetes care. Their accuracy, key to effective glycaemic management, is usually measured using the mean absolute relative difference of the interstitial fluid sensor compared to reference blood glucose readings. However, mean absolute relative difference is not standardised and has limitations. This review aims to provide a consensus opinion on assessing accuracy of interstitial fluid glucose sensing technologies. Mean absolute relative difference is influenced by glucose distribution and rate of change; hence, we express caution on the reliability of comparing mean absolute relative difference data from different study systems and conditions. We also review the pitfalls associated with mean absolute relative difference at different glucose levels and explore additional ways of assessing accuracy of interstitial fluid devices. Importantly, much data indicate that current practice of assessing accuracy of different systems based on individualised mean absolute relative difference results has limitations, which have potential clinical implications. Healthcare professionals must understand the factors that influence mean absolute relative difference as a metric for accuracy and look at additional assessments, such as consensus error grid analysis, when evaluating continuous glucose monitoring and flash glucose monitoring systems in diabetes care. This in turn will ensure that management decisions based on interstitial fluid sensor data are both effective and safe.

  4. Continued glucose output after re-feeding contributes to glucose intolerance in hyperthyroidism.

    OpenAIRE

    Holness, M J; Sugden, M C

    1987-01-01

    The effects of hyperthyroidism to elicit glucose intolerance after glucose administration were decreased under conditions where hepatic glucose output was suppressed. It is concluded that continued hepatic glucose output contributes to abnormal glucose tolerance in hyperthyroidism.

  5. Challenges and perspectives in continuous glucose monitoring.

    Science.gov (United States)

    van Enter, Benjamin Jasha; von Hauff, Elizabeth

    2018-04-24

    Diabetes is a global epidemic that threatens the health and well-being of hundreds of millions of people. The first step in patient treatment is to monitor glucose levels. Currently this is most commonly done using enzymatic strips. This approach suffers from several limitations, namely it requires a blood sample and is therefore invasive, the quality and the stability of the enzymatic strips vary widely, and the patient is burdened by performing the measurement themselves. This results in dangerous fluctuations in glucose levels often going undetected. There is currently intense research towards new approaches in glucose detection that would enable non-invasive continuous glucose monitoring (CGM). In this review, we explore the state-of-the-art in glucose detection technologies. In particular, we focus on the physical mechanisms behind different approaches, and how these influence and determine the accuracy and reliability of glucose detection. We begin by reviewing the basic physical and chemical properties of the glucose molecule. Although these play a central role in detection, especially the anomeric ratio, they are surprisingly often overlooked in the literature. We then review state-of-the art and emerging detection methods. Finally, we survey the current market for glucometers. Recent results show that past challenges in glucose detection are now being overcome, thereby enabling the development of smart wearable devices for non-invasive continuous glucose monitoring. These new directions in glucose detection have enormous potential to improve the quality of life of millions of diabetics, as well as offer insight into the development, treatment and even prevention of the disease.

  6. Continuous glucose monitoring in acute coronary syndrome.

    Science.gov (United States)

    Rodríguez-Quintanilla, Karina Alejandra; Lavalle-González, Fernando Javier; Mancillas-Adame, Leonardo Guadalupe; Zapata-Garrido, Alfonso Javier; Villarreal-Pérez, Jesús Zacarías; Tamez-Pérez, Héctor Eloy

    2013-01-01

    Diabetes mellitus is an independent risk factor for cardiovascular disease. To compare the efficacy of devices for continuous glucose monitoring and capillary glucose monitoring in hospitalized patients with acute coronary syndrome using the following parameters: time to achieve normoglycemia, period of time in normoglycemia, and episodes of hypoglycemia. We performed a pilot, non-randomized, unblinded clinical trial that included 16 patients with acute coronary artery syndrome, a capillary or venous blood glucose ≥ 140 mg/dl, and treatment with a continuous infusion of fast acting human insulin. These patients were randomized into 2 groups: a conventional group, in which capillary measurement and recording as well as insulin adjustment were made every 4h, and an intervention group, in which measurement and recording as well as insulin adjustment were made every hour with a subcutaneous continuous monitoring system. Student's t-test was applied for mean differences and the X(2) test for qualitative variables. We observed a statistically significant difference in the mean time for achieving normoglycemia, favoring the conventional group with a P = 0.02. Continuous monitoring systems are as useful as capillary monitoring for achieving normoglycemia. Copyright © 2012 Instituto Nacional de Cardiología Ignacio Chávez. Published by Masson Doyma México S.A. All rights reserved.

  7. Continuous glucose monitoring systems for type 1 diabetes mellitus

    NARCIS (Netherlands)

    Langendam, Miranda; Luijf, Yoeri M.; Hooft, Lotty; DeVries, J. Hans; Mudde, Aart H.; Scholten, Rob J. P. M.

    2012-01-01

    Background Self-monitoring of blood glucose is essential to optimise glycaemic control in type 1 diabetes mellitus. Continuous glucose monitoring (CGM) systems measure interstitial fluid glucose levels to provide semi-continuous information about glucose levels, which identifies fluctuations that

  8. Continuous glucose monitoring, oral glucose tolerance, and insulin - glucose parameters in adolescents with simple obesity.

    Science.gov (United States)

    El Awwa, A; Soliman, A; Al-Ali, M; Yassin, M; De Sanctis, V

    2012-09-01

    In obese adolescents pancreatic beta-cells may not be able to cope with insulin resistance leading to hyperglycemia and type2 diabetes (T2DM To assess oral glucose tolerance, 72-h continuous blood glucose concentrations (CGM) and calculate homeostatic model assessment (HOMA), and the quantitative insulin sensitivity check index (QUICKI) in 13 adolescents with simple obesity (BMI SDS=4 ± 1.06). OGTT performed in 13 obese adolescents (13.47 ± 3 years) revealed 3 cases (23%) with impaired fasting glucose (IFG: fasting glucose >5.6 mmol/L), 4 cases (30%) with impaired glucose tolerance (IGT: 2h blood glucose >7.8 continuous glucose monitoring system ( CGMS), IFG was detected in 4 cases, the maximum serum blood glucose (BG : 2h or more after meal) was >7.8 and 11.1 mmol/L (diabetes) in one case (7.6%). Five cases had a minimum BG recorded of 2.6 and QUICKI values obese adolescents, CGMS is superior to OGTT and HbA1C in detecting glycemic abnormalities, which appears to be secondary to insulin resistance.

  9. Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose-error grid analysis.

    Science.gov (United States)

    Clarke, William L; Anderson, Stacey; Farhy, Leon; Breton, Marc; Gonder-Frederick, Linda; Cox, Daniel; Kovatchev, Boris

    2005-10-01

    To compare the clinical accuracy of two different continuous glucose sensors (CGS) during euglycemia and hypoglycemia using continuous glucose-error grid analysis (CG-EGA). FreeStyle Navigator (Abbott Laboratories, Alameda, CA) and MiniMed CGMS (Medtronic, Northridge, CA) CGSs were applied to the abdomens of 16 type 1 diabetic subjects (age 42 +/- 3 years) 12 h before the initiation of the study. Each system was calibrated according to the manufacturer's recommendations. Each subject underwent a hyperinsulinemic-euglycemic clamp (blood glucose goal 110 mg/dl) for 70-210 min followed by a 1-mg.dl(-1).min(-1) controlled reduction in blood glucose toward a nadir of 40 mg/dl. Arterialized blood glucose was determined every 5 min using a Beckman Glucose Analyzer (Fullerton, CA). CGS glucose recordings were matched to the reference blood glucose with 30-s precision, and rates of glucose change were calculated for 5-min intervals. CG-EGA was used to quantify the clinical accuracy of both systems by estimating combined point and rate accuracy of each system in the euglycemic (70-180 mg/dl) and hypoglycemic (<70 mg/dl) ranges. A total of 1,104 data pairs were recorded in the euglycemic range and 250 data pairs in the hypoglycemic range. Overall correlation between CGS and reference glucose was similar for both systems (Navigator, r = 0.84; CGMS, r = 0.79, NS). During euglycemia, both CGS systems had similar clinical accuracy (Navigator zones A + B, 88.8%; CGMS zones A + B, 89.3%, NS). However, during hypoglycemia, the Navigator was significantly more clinically accurate than the CGMS (zones A + B = 82.4 vs. 61.6%, Navigator and CGMS, respectively, P < 0.0005). CG-EGA is a helpful tool for evaluating and comparing the clinical accuracy of CGS systems in different blood glucose ranges. CG-EGA provides accuracy details beyond other methods of evaluation, including correlational analysis and the original EGA.

  10. Continuous Glucose Monitoring in Newborn Infants

    Science.gov (United States)

    Thomas, Felicity; Signal, Mathew; Harris, Deborah L.; Weston, Philip J.; Harding, Jane E.; Shaw, Geoffrey M.

    2014-01-01

    Neonatal hypoglycemia is common and can cause serious brain injury. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing blood glucose (BG) measurements. Calibration algorithms use BG measurements to convert sensor signals into CGM data. Thus, inaccuracies in calibration BG measurements directly affect CGM values and any metrics calculated from them. The aim was to quantify the effect of timing delays and calibration BG measurement errors on hypoglycemia metrics in newborn infants. Data from 155 babies were used. Two timing and 3 BG meter error models (Abbott Optium Xceed, Roche Accu-Chek Inform II, Nova Statstrip) were created using empirical data. Monte-Carlo methods were employed, and each simulation was run 1000 times. Each set of patient data in each simulation had randomly selected timing and/or measurement error added to BG measurements before CGM data were calibrated. The number of hypoglycemic events, duration of hypoglycemia, and hypoglycemic index were then calculated using the CGM data and compared to baseline values. Timing error alone had little effect on hypoglycemia metrics, but measurement error caused substantial variation. Abbott results underreported the number of hypoglycemic events by up to 8 and Roche overreported by up to 4 where the original number reported was 2. Nova results were closest to baseline. Similar trends were observed in the other hypoglycemia metrics. Errors in blood glucose concentration measurements used for calibration of CGM devices can have a clinically important impact on detection of hypoglycemia. If CGM devices are going to be used for assessing hypoglycemia it is important to understand of the impact of these errors on CGM data. PMID:24876618

  11. The continuous glucose monitoring sensor in neonatal intensive care

    OpenAIRE

    Beardsall, K; Ogilvy-Stuart, A; Ahluwalia, J; Thompson, M; Dunger, D

    2005-01-01

    Objective: To determine the feasibility of continuous glucose monitoring in the very low birthweight baby requiring intensive care, as these infants are known to be at high risk of abnormalities of glucose control.

  12. Accuracy of a real-time continuous glucose monitoring system in children with septic shock: A pilot study

    OpenAIRE

    Prabhudesai, Sumant; Kanjani, Amruta; Bhagat, Isha; Ravikumar, Karnam G.; Ramachandran, Bala

    2015-01-01

    Aims: The aim of this prospective, observational study was to determine the accuracy of a real-time continuous glucose monitoring system (CGMS) in children with septic shock. Subjects and Methods: Children aged 30 days to 18 years admitted to the Pediatric Intensive Care Unit with septic shock were included. A real-time CGMS sensor was used to obtain interstitial glucose readings. CGMS readings were compared statistically with simultaneous laboratory blood glucose (BG). Results: Nineteen chil...

  13. Reproducibility and reliability of hypoglycaemic episodes recorded with Continuous Glucose Monitoring System (CGMS) in daily life

    DEFF Research Database (Denmark)

    Høi-Hansen, T; Pedersen-Bjergaard, U; Thorsteinsson, B

    2005-01-01

    AIM: Continuous glucose monitoring may reveal episodes of unrecognized hypoglycaemia. We evaluated reproducibility and reliability of hypoglycaemic episodes recorded in daily life by the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS). METHODS: Twenty-nine adult patients with Type 1...... data were recalibrated generating four different CGMS data sets [left-A (left side of abdomen, calibration set A), left-B, right-A and right-B]. Agreement between CGMS data sets was evaluated during hypoglycaemic events, comparing CGMS readings = 2.2 mmol/l with nadir values from corresponding CGMS...... data sets. CGMS readings were also compared with independent self-monitored blood glucose (SMBG) values. RESULTS: With hypoglycaemia (CGMS readings = 2.2 mmol/l) in calibration set left-A, values below 3.5 mmol/l were present in 99% (95% CI: 95-100%) of samples in left-B, 91% (95% CI: 84...

  14. Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones.

    Science.gov (United States)

    Elsherif, Mohamed; Hassan, Mohammed Umair; Yetisen, Ali K; Butt, Haider

    2018-05-17

    Low-cost, robust, and reusable continuous glucose monitoring systems that can provide quantitative measurements at point-of-care settings is an unmet medical need. Optical glucose sensors require complex and time-consuming fabrication processes, and their readouts are not practical for quantitative analyses. Here, a wearable contact lens optical sensor was created for the continuous quantification of glucose at physiological conditions, simplifying the fabrication process and facilitating smartphone readouts. A photonic microstructure having a periodicity of 1.6 μm was printed on a glucose-selective hydrogel film functionalized with phenylboronic acid. Upon binding with glucose, the microstructure volume swelled, which modulated the periodicity constant. The resulting change in the Bragg diffraction modulated the space between zero- and first-order spots. A correlation was established between the periodicity constant and glucose concentration within 0-50 mM. The sensitivity of the sensor was 12 nm mM -1 , and the saturation response time was less than 30 min. The sensor was integrated with commercial contact lenses and utilized for continuous glucose monitoring using smartphone camera readouts. The reflected power of the first-order diffraction was measured via a smartphone application and correlated to the glucose concentrations. A short response time of 3 s and a saturation time of 4 min was achieved in the continuous monitoring mode. Glucose-sensitive photonic microstructures may have applications in point-of-care continuous monitoring devices and diagnostics at home settings.

  15. Continuous Glucose Monitoring in Patients with Abnormal Glucose Tolerance during Pregnancy: A Case Series

    Directory of Open Access Journals (Sweden)

    Mie Tonoike

    2016-01-01

    Full Text Available Abnormal glucose tolerance during pregnancy is associated with perinatal complications. We used continuous glucose monitoring (CGM in pregnant women with glucose intolerance to achieve better glycemic control and to evaluate the maternal glucose fluctuations. We also used CGM in women without glucose intolerance (the control cases. Furthermore, the standard deviation (SD and mean amplitude of glycemic excursions (MAGE were calculated for each case. For the control cases, the glucose levels were tightly controlled within a very narrow range; however, the SD and MAGE values in pregnant women with glucose intolerance were relativity high, suggesting postprandial hyperglycemia. Our results demonstrate that pregnant women with glucose intolerance exhibited greater glucose fluctuations compared with the control cases. The use of CGM may help to improve our understanding of glycemic patterns and may have beneficial effects on perinatal glycemic control, such as the detection of postprandial hyperglycemia in pregnant women.

  16. Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application.

    Science.gov (United States)

    Kovatchev, Boris P; Clarke, William L; Breton, Marc; Brayman, Kenneth; McCall, Anthony

    2005-12-01

    Continuous glucose monitors (CGMs) collect detailed blood glucose (BG) time series, which carry significant information about the dynamics of BG fluctuations. In contrast, the methods for analysis of CGM data remain those developed for infrequent BG self-monitoring. As a result, important information about the temporal structure of the data is lost during the translation of raw sensor readings into clinically interpretable statistics and images. The following mathematical methods are introduced into the field of CGM data interpretation: (1) analysis of BG rate of change; (2) risk analysis using previously reported Low/High BG Indices and Poincare (lag) plot of risk associated with temporal BG variability; and (3) spatial aggregation of the process of BG fluctuations and its Markov chain visualization. The clinical application of these methods is illustrated by analysis of data of a patient with Type 1 diabetes mellitus who underwent islet transplantation and with data from clinical trials. Normative data [12,025 reference (YSI device, Yellow Springs Instruments, Yellow Springs, OH) BG determinations] in patients with Type 1 diabetes mellitus who underwent insulin and glucose challenges suggest that the 90%, 95%, and 99% confidence intervals of BG rate of change that could be maximally sustained over 15-30 min are [-2,2], [-3,3], and [-4,4] mg/dL/min, respectively. BG dynamics and risk parameters clearly differentiated the stages of transplantation and the effects of medication. Aspects of treatment were clearly visualized by graphs of BG rate of change and Low/High BG Indices, by a Poincare plot of risk for rapid BG fluctuations, and by a plot of the aggregated Markov process. Advanced analysis and visualization of CGM data allow for evaluation of dynamical characteristics of diabetes and reveal clinical information that is inaccessible via standard statistics, which do not take into account the temporal structure of the data. The use of such methods improves the

  17. Toward an injectable continuous osmotic glucose sensor.

    Science.gov (United States)

    Johannessen, Erik; Krushinitskaya, Olga; Sokolov, Andrey; Philipp, Häfliger; Hoogerwerf, Arno; Hinderling, Christian; Kautio, Kari; Lenkkeri, Jaakko; Strömmer, Esko; Kondratyev, Vasily; Tønnessen, Tor Inge; Mollnes, Tom Eirik; Jakobsen, Henrik; Zimmer, Even; Akselsen, Bengt

    2010-07-01

    The growing pandemic of diabetes mellitus places a stringent social and economic burden on the society. A tight glycemic control circumvents the detrimental effects, but the prerogative is the development of new more effective tools capable of longterm tracking of blood glucose (BG) in vivo. Such discontinuous sensor technologies will benefit from an unprecedented marked potential as well as reducing the current life expectancy gap of eight years as part of a therapeutic regime. A sensor technology based on osmotic pressure incorporates a reversible competitive affinity assay performing glucose-specific recognition. An absolute change in particles generates a pressure that is proportional to the glucose concentration. An integrated pressure transducer and components developed from the silicon micro- and nanofabrication industry translate this pressure into BG data. An in vitro model based on a 3.6 x 8.7 mm large pill-shaped implant is equipped with a nanoporous membrane holding 4-6 nm large pores. The affinity assay offers a dynamic range of 36-720 mg/dl with a resolution of +/-16 mg/dl. An integrated 1 x 1 mm(2) large control chip samples the sensor signals for data processing and transmission back to the reader at a total power consumption of 76 microW. Current studies have demonstrated the design, layout, and performance of a prototype osmotic sensor in vitro using an affinity assay solution for up to four weeks. The small physical size conforms to an injectable device, forming the basis of a conceptual monitor that offers a tight glycemic control of BG. 2010 Diabetes Technology Society.

  18. A contact lens with integrated telecommunication circuit and sensors for wireless and continuous tear glucose monitoring

    International Nuclear Information System (INIS)

    Yao, H; Liao, Y; Lingley, A R; Afanasiev, A; Lähdesmäki, I; Otis, B P; Parviz, B A

    2012-01-01

    We present an integrated functional contact lens, composed of a differential glucose sensor module, metal interconnects, sensor read-out circuit, antenna and telecommunication circuit, to monitor tear glucose levels wirelessly, continuously and non-invasively. The electrochemical differential sensor module is based on immobilization of activated and de-activated glucose oxidase. We characterized the sensor on a model polymer eye and determined that it showed good repeatability, molecular interference rejection and linearity in the range of 0–2 mM glucose, covering normal tear glucose concentrations (0.1–0.6 mM). We also report the temperature, ageing and protein-fouling sensitivity of the sensor. We report the design and implementation of a low-power (3 µW) sensor read-out and telecommunication circuit to deliver wireless power and transmit data for the sensor module. Using this small chip (0.36 mm 2 ), we produced an integrated contact lens with sensors and demonstrated wireless operation of the system and glucose read-out over the distance of several centimeters. (paper)

  19. Evaluating clinical accuracy of continuous glucose monitoring devices: other methods

    NARCIS (Netherlands)

    Wentholt, Iris M. E.; Hart, August A.; Hoekstra, Joost B. L.; DeVries, J. Hans

    2008-01-01

    With more and more continuous glucose monitoring devices entering the market, the importance of adequate accuracy assessment grows. This review discusses pros and cons of Regression Analysis and Correlation Coefficient, Relative Difference measures, Bland Altman plot, ISO criteria, combined curve

  20. Flash Glucose Monitoring: Differences Between Intermittently Scanned and Continuously Stored Data.

    Science.gov (United States)

    Pleus, Stefan; Kamecke, Ulrike; Link, Manuela; Haug, Cornelia; Freckmann, Guido

    2018-03-01

    The flash glucose monitoring system FreeStyle Libre (Abbott Diabetes Care Ltd., Witney, UK) measures interstitial glucose concentrations and continuously stores measurement values every 15 minutes. To obtain a current glucose reading, users have to scan the sensor with the reader. In a clinical trial, 5% of the scanned data showed relative differences of more than ±10% compared with continuously stored data points (median -0.5%). Such differences might impact results of studies using this system. It should be indicated whether scanned or continuously stored data were used for analyses. Health care professionals might have to differentiate between data reports from clinical software and the scanned data their patients are provided with. Additional information on these differences and their potential impact on therapeutic decisions would be helpful.

  1. Glucose metabolism disorder in obese children assessed by continuous glucose monitoring system.

    Science.gov (United States)

    Zou, Chao-Chun; Liang, Li; Hong, Fang; Zhao, Zheng-Yan

    2008-02-01

    Continuous glucose monitoring system (CGMS) can measure glucose levels at 5-minute intervals over a few days, and may be used to detect hypoglycemia, guide insulin therapy, and control glucose levels. This study was undertaken to assess the glucose metabolism disorder by CGMS in obese children. Eighty-four obese children were studied. Interstitial fluid (ISF) glucose levels were measured by CGMS for 24 hours covering the time for oral glucose tolerance test (OGTT). Impaired glucose tolerance (IGT), impaired fasting glucose (IFG), type 2 diabetic mellitus (T2DM) and hypoglycemia were assessed by CGMS. Five children failed to complete CGMS test. The glucose levels in ISF measured by CGMS were highly correlated with those in capillary samples (r=0.775, Pobese children who finished the CGMS, 2 children had IFG, 2 had IGT, 3 had IFG + IGT, and 2 had T2DM. Nocturnal hypoglycemia was noted during the overnight fasting in 11 children (13.92%). Our data suggest that glucose metabolism disorder including hyperglycemia and hypoglycemia is very common in obese children. Further studies are required to improve the precision of the CGMS in children.

  2. Oral glucose tolerance test and continuous glucose monitoring to assess diabetes development in cystic fibrosis patients.

    Science.gov (United States)

    Clemente León, María; Bilbao Gassó, Laura; Moreno-Galdó, Antonio; Campos Martorrell, Ariadna; Gartner Tizzano, Silvia; Yeste Fernández, Diego; Carrascosa Lezcano, Antonio

    2018-01-01

    Patients with cystic fibrosis (CF) undergo a slow and progressive process toward diabetes. Oral glucose tolerance test (OGTT) is recommended to diagnose impaired glucose levels in these patients. Continuous glucose monitoring (CGM) measures glucose profiles under real-life conditions. To compare OGTT and CGM results in CF patients. Paired OGTT and 6-day CGM profiles (146.2±9.1h/patient) were performed in 30 CF patients aged 10-18 years. According to OGTT, 14 patients had normal glucose tolerance (NGT), 14 abnormal glucose tolerance (AGT), and two cystic fibrosis-related diabetes (CFRD). In 27 patients (13 NGT, 13 AGT, 1 CFRD), CGM showed glucose values ranging from 140 to 200mg/dL during similar monitoring times (2%-14% with NGT, 1%-16.9% with AGT, and 3% with CFRD). Glucose peak levels ≥200mg/dL were seen in seven patients (3 NGT, 3 AGT, 1 CFRD). According to CGM, two patients had all glucose values under 140mg/dL (1 NGT, 1 AGT). Seventeen patients had glucose levels ranging from 140 to 200mg/dL (10 NGT, 6 AGT, 1 CFRD). Ten patients (3 NGT, 7 AGT) had glucose values ≥200mg/dL for ≤1% of the monitoring time and one (CFRD) for >1% of the monitoring time. OGTT results did not agree with those of the CGM. CGM allows for diagnosis of glucose changes not detected by OGTT. Such changes may contribute to optimize pre-diabetes management in CF patients. Copyright © 2017 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Continuous tissue glucose monitoring correlates with measurement of intermittent capillary glucose in patients with distributive shock.

    Science.gov (United States)

    Ballesteros, D; Martínez, Ó; Blancas Gómez-Casero, R; Martín Parra, C; López Matamala, B; Estébanez, B; Chana, M

    2015-10-01

    Intermittent glycemic measurements in patients admitted to the intensive care unit (ICU) can result in episodes of severe hypoglycemia or in a poor control of glycemia range. We designed a study to assess accuracy and reliability of continuous monitoring of tissue glucose for patients with distributive shock. Consecutive patients admitted to the ICU with a diagnosis of distributive shock and the need of insulin infusion for glycemic control were included in the study. These patients were implanted a Continuous Glucose Control Monitoring System (CGMS) with the sensor inserted subcutaneously into the abdominal wall. CGMS values were recorded every 5min. Capillary glucose (CG) was monitored for adjusting insulin perfusion according to the ICU protocol. Correlation between both methods was assessed. A total of 11,673 CGMS and 348 CG values were recorded. In five patients, CGMS failed to detect tissue glucose. A glucose value <3.33mmol/l (<60mg/dl) was observed in 3.6% of CGMS and in 0.29% CG values. 295 pairs of measurements were included in the statistical analysis for correlation assessment. The intraclass correlation coefficient was 0.706. The Pearson correlation coefficient was 0.71 (p<0.0001, 95% CI 0.65-0.76). The mean of differences between both measurement methods was 0.22mmol/l (3.98mg/dl) (95% CI 0.66-7.31). When the Continuous Glucose Control Monitoring System (CGMS) is able to obtain data (75% of the patients), there is correlation between the values obtained by this method and capillary blood glucose in patients with distributive shock. CGMS can detect more episodes of glycemic excursions outside the normal range than intermittent capillary glucose monitoring. Variables that may impair glucose metabolism and peripheral soft tissues perfusion could impair CGMS measurements. Copyright © 2014 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.

  4. Measurement properties of continuous text reading performance tests.

    Science.gov (United States)

    Brussee, Tamara; van Nispen, Ruth M A; van Rens, Ger H M B

    2014-11-01

    Measurement properties of tests to assess reading acuity or reading performance have not been extensively evaluated. This study aims to provide an overview of the literature on available continuous text reading tests and their measurement properties. A literature search was performed in PubMed, Embase and PsycInfo. Subsequently, information on design and content of reading tests, study design and measurement properties were extracted using consensus-based standards for selection of health measurement instruments. Quality of studies, reading tests and measurement properties were systematically assessed using pre-specified criteria. From 2334 identified articles, 20 relevant articles were found on measurement properties of three reading tests in various languages: IReST, MNread Reading Test and Radner Reading Charts. All three reading tests scored high on content validity. Reproducibility studies (repeated measurements between different testing sessions) of the IReST and MNread of commercially available reading tests in different languages were missing. The IReST scored best on inter-language comparison, the MNread scored well in repeatability studies (repeated measurements under the same conditions) and the Radner showed good reproducibility in studies. Although in daily practice there are other continuous text reading tests available meeting the criteria of this review, measurement properties were described in scientific studies for only three of them. Of the few available studies, the quality and content of study design and methodology used varied. For testing existing reading tests and the development of new ones, for example in other languages, we make several recommendations, including careful description of patient characteristics, use of objective and subjective lighting levels, good control of working distance, documentation of the number of raters and their training, careful documentation of scoring rules and the use of Bland-Altman analyses or similar for

  5. A Fully Implantable, NFC Enabled, Continuous Interstitial Glucose Monitor

    OpenAIRE

    Anabtawi, Nijad; Freeman, Sabrina; Ferzli, Rony

    2016-01-01

    This work presents an integrated system-on-chip (SoC) that forms the core of a long-term, fully implantable, battery assisted, passive continuous glucose monitor. It integrates an amperometric glucose sensor interface, a near field communication (NFC) wireless front-end and a fully digital switched mode power management unit for supply regulation and on board battery charging. It uses 13.56 MHz (ISM) band to harvest energy and backscatter data to an NFC reader. System was implemented in 14nm ...

  6. A Fully Implantable, NFC Enabled, Continuous Interstitial Glucose Monitor.

    Science.gov (United States)

    Anabtawi, Nijad; Freeman, Sabrina; Ferzli, Rony

    2016-02-01

    This work presents an integrated system-on-chip (SoC) that forms the core of a long-term, fully implantable, battery assisted, passive continuous glucose monitor. It integrates an amperometric glucose sensor interface, a near field communication (NFC) wireless front-end and a fully digital switched mode power management unit for supply regulation and on board battery charging. It uses 13.56 MHz (ISM) band to harvest energy and backscatter data to an NFC reader. System was implemented in 14nm CMOS technology and validated with post layout simulations.

  7. Toward developing a standardized Arabic continuous text reading chart.

    Science.gov (United States)

    Alabdulkader, Balsam; Leat, Susan Jennifer

    Near visual acuity is an essential measurement during an oculo-visual assessment. Short duration continuous text reading charts measure reading acuity and other aspects of reading performance. There is no standardized version of such chart in Arabic. The aim of this study is to create sentences of equal readability to use in the development of a standardized Arabic continuous text reading chart. Initially, 109 Arabic pairs of sentences were created for use in constructing a chart with similar layout to the Colenbrander chart. They were created to have the same grade level of difficulty and physical length. Fifty-three adults and sixteen children were recruited to validate the sentences. Reading speed in correct words per minute (CWPM) and standard length words per minute (SLWPM) was measured and errors were counted. Criteria based on reading speed and errors made in each sentence pair were used to exclude sentence pairs with more outlying characteristics, and to select the final group of sentence pairs. Forty-five sentence pairs were selected according to the elimination criteria. For adults, the average reading speed for the final sentences was 166 CWPM and 187 SLWPM and the average number of errors per sentence pair was 0.21. Childrens' average reading speed for the final group of sentences was 61 CWPM and 72 SLWPM. Their average error rate was 1.71. The reliability analysis showed that the final 45 sentence pairs are highly comparable. They will be used in constructing an Arabic short duration continuous text reading chart. Copyright © 2016 Spanish General Council of Optometry. Published by Elsevier España, S.L.U. All rights reserved.

  8. Accuracy of a Fourth-Generation Subcutaneous Continuous Glucose Sensor.

    Science.gov (United States)

    Christiansen, Mark P; Garg, Satish K; Brazg, Ronald; Bode, Bruce W; Bailey, Timothy S; Slover, Robert H; Sullivan, Ashley; Huang, Suiying; Shin, John; Lee, Scott W; Kaufman, Francine R

    2017-08-01

    This study evaluated the accuracy and performance of a fourth-generation subcutaneous glucose sensor (Guardian ™ Sensor 3) in the abdomen and arm. Eighty-eight subjects (14-75 years of age, mean ± standard deviation [SD] of 42.0 ± 19.1 years) with type 1 or type 2 diabetes participated in the study. Subjects wore two sensors in the abdomen that were paired with either a MiniMed ™ 640G insulin pump, or an iPhone ® or iPod ® touch ® running a glucose monitoring mobile application (Guardian Connect system) and a third sensor in the arm, which was connected to a glucose sensor recorder (GSR). Subjects were also asked to undergo in-clinic visits of 12-14 h on study days 1, 3, and 7 for frequent blood glucose sample testing using a Yellow Springs Instrument (YSI) reference. The overall mean absolute relative difference (MARD ± SD) between abdomen sensor glucose (SG) and YSI reference values was 9.6% ± 9.0% and 9.4% ± 9.8% for the MiniMed 640G insulin pump and Guardian Connect system, respectively; and 8.7% ± 8.0% between arm SG and YSI reference values. The percentage of SG values within 20% agreement of the YSI reference value (for YSI >80 mg/dL) was 90.7% with the MiniMed 640G insulin pump, 91.8% with the Guardian Connect system, and 93.1% for GSR-connected arm sensors. Mean functional sensor life, when calibrating 3-4 times/day, was 145.9 ± 39.3 h for sensors paired with the MiniMed 640G insulin pump, 146.1 ± 41.6 h for sensors paired with the Guardian Connect system, and 147.6 ± 40.4 h for sensors connected to the GSR. Responses to survey questions regarding sensor comfort and ease of use were favorable. The Guardian Sensor 3 glucose sensor, whether located in abdomen or the arm, provided accurate glucose readings when compared with the YSI reference and demonstrated functional life commensurate with the intended 7-day use. ClinicalTrials.gov : NCT02246582.

  9. PROFESSIONAL FLASH CONTINUOUS GLUCOSE MONITORING WITH AMBULATORY GLUCOSE PROFILE REPORTING TO SUPPLEMENT A1C: RATIONALE AND PRACTICAL IMPLEMENTATION.

    Science.gov (United States)

    Hirsch, Irl B; Verderese, Carol A

    2017-11-01

    Recent consensus statements strongly advocate downloading and interpreting continuous glucose data for diabetes management in patients with type 1 or 2 diabetes. Supplementing periodic glycated hemoglobin (A1C) testing with intermittent continuous glucose monitoring (CGM) using a standardized report form known as the ambulatory glucose profile (AGP) is an evolving standard of care. The rationale for this approach and its implementation with a recently approved novel monitoring technology are explored. Search of the medical literature, professional guidelines, and real-world evidence guided this introduction of an integrative practice framework that uses AGP in conjunction with intermittent flash continuous glucose monitoring (FCGM) as a supplement to A1C testing. The combination of intermittent continuous glucose pattern analysis, standardized glucose metrics, and a readily interpretable data report has the potential to practically extend the recognized benefits of CGM to more patients and clarify the relationship between A1C and average glucose levels in individual cases. Novel FCGM technologies portend greater use of continuous forms of glucose monitoring and wider adoption of AGP report analysis. Additional formal and empirical evidence is needed to more fully characterize best practice. A1C = glycated hemoglobin; AGP = ambulatory glucose profile; CGM = continuous glucose monitoring; FCGM = flash continuous glucose monitoring; IQR = interquartile range; SMBG = self-monitoring of blood glucose.

  10. Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetes

    OpenAIRE

    Poolsup, Nalinee; Suksomboon, Naeti; Kyaw, Aye Mon

    2013-01-01

    Diabetes mellitus is a chronic disease that necessitates continuing treatment and patient self-care education. Monitoring of blood glucose to near normal level without hypoglycemia becomes a challenge in the management of diabetes. Although self monitoring of blood glucose (SMBG) can provide daily monitoring of blood glucose level and help to adjust therapy, it cannot detect hypoglycemic unawareness and nocturnal hypoglycemia which occurred mostly in T1DM pediatrics. Continuous glucose monito...

  11. Crosslinked basement membrane-based coatings enhance glucose sensor function and continuous glucose monitoring in vivo.

    Science.gov (United States)

    Klueh, Ulrike; Ludzinska, Izabela; Czajkowski, Caroline; Qiao, Yi; Kreutzer, Donald L

    2018-01-01

    Overcoming sensor-induced tissue reactions is an essential element of achieving successful continuous glucose monitoring (CGM) in the management of diabetes, particularly when used in closed loop technology. Recently, we demonstrated that basement membrane (BM)-based glucose sensor coatings significantly reduced tissue reactions at sites of device implantation. However, the biocompatible BM-based biohydrogel sensor coating rapidly degraded over a less than a 3-week period, which effectively eliminated the protective sensor coating. In an effort to increase the stability and effectiveness of the BM coating, we evaluated the impact of crosslinking BM utilizing glutaraldehyde as a crosslinking agent, designated as X-Cultrex. Sensor performance (nonrecalibrated) was evaluated for the impact of these X-Cultrex coatings in vitro and in vivo. Sensor performance was assessed over a 28-day time period in a murine CGM model and expressed as mean absolute relative difference (MARD) values. Tissue reactivity of Cultrex-coated, X-Cultrex-coated, and uncoated glucose sensors was evaluated over a 28-day time period in vivo using standard histological techniques. These studies demonstrated that X-Cultrex-based sensor coatings had no effect on glucose sensor function in vitro. In vivo, glucose sensor performance was significantly enhanced following X-Cultrex coating throughout the 28-day study. Histological evaluations of X-Cultrex-treated sensors demonstrated significantly less tissue reactivity when compared to uncoated sensors. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 7-16, 2018. © 2017 Wiley Periodicals, Inc.

  12. Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities.

    Science.gov (United States)

    Rodbard, David

    2016-02-01

    Continuous glucose monitoring (CGM) provides information unattainable by intermittent capillary blood glucose, including instantaneous real-time display of glucose level and rate of change of glucose, alerts and alarms for actual or impending hypo- and hyperglycemia, "24/7" coverage, and the ability to characterize glycemic variability. Progressively more accurate and precise, reasonably unobtrusive, small, comfortable, user-friendly devices connect to the Internet to share information and are sine qua non for a closed-loop artificial pancreas. CGM can inform, educate, motivate, and alert people with diabetes. CGM is medically indicated for patients with frequent, severe, or nocturnal hypoglycemia, especially in the presence of hypoglycemia unawareness. Surprisingly, despite tremendous advances, utilization of CGM has remained fairly limited to date. Barriers to use have included the following: (1) lack of Food and Drug Administration approval, to date, for insulin dosing ("nonadjuvant use") in the United States and for use in hospital and intensive care unit settings; (2) cost and variable reimbursement; (3) need for recalibrations; (4) periodic replacement of sensors; (5) day-to-day variability in glycemic patterns, which can limit the predictability of findings based on retrospective, masked "professional" use; (6) time, implicit costs, and inconvenience for uploading of data for retrospective analysis; (7) lack of fair and reasonable reimbursement for physician time; (8) inexperience and lack of training of physicians and other healthcare professionals regarding interpretation of CGM results; (9) lack of standardization of software methods for analysis of CGM data; and (10) need for professional medical organizations to develop and disseminate additional clinical practice guidelines regarding the role of CGM. Ongoing advances in technology and clinical research have addressed several of these barriers. Use of CGM in conjunction with an insulin pump with

  13. A comparative effectiveness analysis of three continuous glucose monitors.

    Science.gov (United States)

    Damiano, Edward R; El-Khatib, Firas H; Zheng, Hui; Nathan, David M; Russell, Steven J

    2013-02-01

    To compare three continuous glucose monitoring (CGM) devices in subjects with type 1 diabetes under closed-loop blood glucose (BG) control. Six subjects with type 1 diabetes (age 52 ± 14 years, diabetes duration 32 ± 14 years) each participated in two 51-h closed-loop BG control experiments in the hospital. Venous plasma glucose (PG) measurements (GlucoScout, International Biomedical) obtained every 15 min (2,360 values) were paired in time with corresponding CGM glucose (CGMG) measurements obtained from three CGM devices, the Navigator (Abbott Diabetes Care), the Seven Plus (DexCom), and the Guardian (Medtronic), worn simultaneously by each subject. Errors in paired PG-CGMG measurements and data reporting percentages were obtained for each CGM device. The Navigator had the best overall accuracy, with an aggregate mean absolute relative difference (MARD) of all paired points of 11.8 ± 11.1% and an average MARD across all 12 experiments of 11.8 ± 3.8%. The Seven Plus and Guardian produced aggregate MARDs of all paired points of 16.5 ± 17.8% and 20.3 ± 18.0%, respectively, and average MARDs across all 12 experiments of 16.5 ± 6.7% and 20.2 ± 6.8%, respectively. Data reporting percentages, a measure of reliability, were 76% for the Seven Plus and nearly 100% for the Navigator and Guardian. A comprehensive head-to-head-to-head comparison of three CGM devices for BG values from 36 to 563 mg/dL revealed marked differences in performance characteristics that include accuracy, precision, and reliability. The Navigator outperformed the other two in these areas.

  14. Professional flash continuous glucose monitoring as a supplement to A1C in primary care.

    Science.gov (United States)

    Hirsch, Irl B

    2017-11-01

    Decreasing glycated hemoglobin (A1C) is the primary goal of current diabetes management due to intervention studies in type 1 and type 2 diabetes associating levels <7.0% (53 mmol/mol) with lower complication risk. Strategic self-monitoring of blood glucose (SMBG) is also recommended to achieve greater time in range, with fewer extremes of hypo- or hyperglycemia. Unlike A1C, SMBG can distinguish among fasting, prandial, and postprandial hyperglycemia; uncover glycemic variability, including potentially dangerous hypoglycemia; and provide feedback to patients about the effects of behavior and medication on glycemic control. However, it has the drawback of capturing only static glucose readings and users are often dependent on time-pressed clinicians to interpret numerous data points. A novel flash continuous glucose monitoring (FCGM) device used for a single 2-week period with a readily interpretable data report know as the ambulatory glucose profile (AGP) has the potential to overcome limitations of conventional technologies, with less cost and greater convenience. This review summarizes the rationale for using intermittent FCGM as a supplement to A1C in primary care, and provides a stepwise approach to interpreting the AGP visual display for efficient individualized therapy.

  15. Continuous Glucose Monitoring (CGM) or Blood Glucose Monitoring (BGM): Interactions and Implications.

    Science.gov (United States)

    Heinemann, Lutz

    2018-04-01

    At the 2017 10th annual International Conference on Advanced Technologies and Treatments for Diabetes (ATTD) in Paris, France, four speakers presented their perspectives on the roles of continuous glucose monitoring (CGM) and of blood glucose monitoring (BGM) in patient management within one symposium. These presentations included discussions of the differences in the accuracy of CGM and BGM, a clinical perspective on the physiological reasons behind differences in CGM and BGM values, and an overview of the impact of variations in device accuracy on patients with diabetes. Subsequently a short summary of these presentations is given, highlighting the value of good accuracy of BGM or CGM systems and the ongoing need for standardization. The important role of both BGM and CGM in patient management was a theme across all presentations.

  16. Continuous glucose monitoring systems for type 1 diabetes mellitus.

    Science.gov (United States)

    Langendam, Miranda; Luijf, Yoeri M; Hooft, Lotty; Devries, J Hans; Mudde, Aart H; Scholten, Rob J P M

    2012-01-18

    Self-monitoring of blood glucose is essential to optimise glycaemic control in type 1 diabetes mellitus. Continuous glucose monitoring (CGM) systems measure interstitial fluid glucose levels to provide semi-continuous information about glucose levels, which identifies fluctuations that would not have been identified with conventional self-monitoring. Two types of CGM systems can be defined: retrospective systems and real-time systems. Real-time systems continuously provide the actual glucose concentration on a display. Currently, the use of CGM is not common practice and its reimbursement status is a point of debate in many countries. To assess the effects of CGM systems compared to conventional self-monitoring of blood glucose (SMBG) in patients with diabetes mellitus type 1. We searched The Cochrane Library, MEDLINE, EMBASE and CINAHL for the identification of studies. Last search date was June 8, 2011. Randomised controlled trials (RCTs) comparing retrospective or real-time CGM with conventional self-monitoring of blood glucose levels or with another type of CGM system in patients with type 1 diabetes mellitus. Primary outcomes were glycaemic control, e.g. level of glycosylated haemoglobin A1c (HbA1c) and health-related quality of life. Secondary outcomes were adverse events and complications, CGM derived glycaemic control, death and costs. Two authors independently selected the studies, assessed the risk of bias and performed data-extraction. Although there was clinical and methodological heterogeneity between studies an exploratory meta-analysis was performed on those outcomes the authors felt could be pooled without losing clinical merit. The search identified 1366 references. Twenty-two RCTs meeting the inclusion criteria of this review were identified. The results of the meta-analyses (across all age groups) indicate benefit of CGM for patients starting on CGM sensor augmented insulin pump therapy compared to patients using multiple daily injections of

  17. A continuous read-out TPC for the ALICE upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Lippmann, C., E-mail: C.Lippmann@gsi.de

    2016-07-11

    The largest gaseous Time Projection Chamber (TPC) in the world, the ALICE TPC, will be upgraded based on Micro Pattern Gas Detector technology during the second long shutdown of the CERN Large Hadron Collider in 2018/19. The upgraded detector will operate continuously without the use of a triggered gating grid. It will thus be able to read all minimum bias Pb–Pb events that the LHC will deliver at the anticipated peak interaction rate of 50 kHz for the high luminosity heavy-ion era. New read-out electronics will send the continuous data stream to a new online farm at rates up to 1 TByte/s. A fractional ion feedback of below 1% is required to keep distortions due to space charge in the TPC drift volume at a tolerable level. The new read-out chambers will consist of quadruple stacks of Gas Electron Multipliers (GEM), combining GEM foils with a different hole pitch. Other key requirements such as energy resolution and operational stability have to be met as well. A careful optimisation of the performance in terms of all these parameters was achieved during an extensive R&D program. A working point well within the design specifications was identified with an ion backflow of 0.63%, a local energy resolution of 11.3% (sigma) and a discharge probability comparable to that of standard triple GEM detectors.

  18. Continuous Glucose Monitoring in the Cardiac ICU: Current Use and Future Directions.

    Science.gov (United States)

    Scrimgeour, Laura A; Potz, Brittany A; Sellke, Frank W; Abid, M Ruhul

    2017-11-01

    Perioperative glucose control is highly important, particularly for patients undergoing cardiac surgery. Variable glucose levels before, during and after cardiac surgery lead to increased post-operative complications and patient mortality. [1] Current methods for intensive monitoring and treating hyperglycemia in the Intensive Care Unit (ICU) usually involve hourly glucose monitoring and continuous intravenous insulin infusions. With the advent of more accurate subcutaneous glucose monitoring systems, the role of improved glucose control with newer systems deserves consideration for widespread adoption.

  19. Clinical use of continuous glucose monitoring in adults with type 1 diabetes

    OpenAIRE

    Slattery, David; Choudhary, Pratik

    2017-01-01

    With the emphasis on intensive management of type 1 diabetes, data from studies support frequent monitoring of glucose levels to improve glycemic control and reduce glucose variability, which can be related to an increase in macro and microvascular complications. However, few perform capillary blood glucose that frequently. There are currently two available alternatives that this review will discuss, continuous glucose monitoring (CGM) and flash glucose monitoring. CGM has become an important...

  20. Twenty-four-hour variations in blood glucose level in Japanese type 2 diabetes patients based on continuous glucose monitoring.

    Science.gov (United States)

    Hajime, Maiko; Okada, Yosuke; Mori, Hiroko; Otsuka, Takashi; Kawaguchi, Mayuko; Miyazaki, Megumi; Kuno, Fumi; Sugai, Kei; Sonoda, Satomi; Tanaka, Kenichi; Kurozumi, Akira; Narisawa, Manabu; Torimoto, Keiichi; Arao, Tadashi; Tanaka, Yoshiya

    2018-01-01

    High fluctuations in blood glucose are associated with various complications. The correlation between glycated hemoglobin (HbA1c) level and fluctuations in blood glucose level has not been studied in Japanese patients with type 2 diabetes. In the present study, blood glucose profile stratified by HbA1c level was evaluated by continuous glucose monitoring (CGM) in Japanese type 2 diabetes patients. Our retrospective study included 294 patients with type 2 diabetes who were divided by HbA1c level into five groups (≥6.0 to level and CGM data was analyzed. The primary end-point was the difference in blood glucose fluctuations among the HbA1c groups. The mean blood glucose level increased significantly with increasing HbA1c (P trend  levels of maximum blood glucose, minimum blood glucose, each preprandial blood glucose, each postprandial maximum blood glucose, range of increase in postprandial glucose from pre-meal to after breakfast, the area under the blood concentration-time curve >180 mg/dL and percentage of the area under the blood concentration-time curve >180 mg/dL were higher with higher HbA1c. Mean glucose level and pre-breakfast blood glucose level were significant and independent determinants of HbA1c. In Japanese patients treated for type 2 diabetes, the mean amplitude of glycemic excursions did not correlate with HbA1c, making it difficult to assess blood glucose fluctuations using HbA1c. Parameters other than HbA1c are required to evaluate fluctuations in blood glucose level in patients receiving treatment for type 2 diabetes. © 2017 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.

  1. Continuous Monitoring of Glucose for Type 1 Diabetes: A Health Technology Assessment

    Science.gov (United States)

    Vandersluis, Stacey; Kabali, Conrad; Djalalov, Sandjar; Gajic-Veljanoski, Olga; Wells, David; Holubowich, Corinne

    2018-01-01

    Background Type 1 diabetes is a condition in which the pancreas produces little or no insulin. People with type 1 diabetes must manage their blood glucose levels by monitoring the amount of glucose in their blood and administering appropriate amounts of insulin via injection or an insulin pump. Continuous glucose monitoring may be beneficial compared to self-monitoring of blood glucose using a blood glucose meter. It provides insight into a person's blood glucose levels on a continuous basis, and can identify whether blood glucose levels are trending up or down. Methods We conducted a health technology assessment, which included an evaluation of clinical benefit, value for money, and patient preferences related to continuous glucose monitoring. We compared continuous glucose monitoring with self-monitoring of blood glucose using a finger-prick and a blood glucose meter. We performed a systematic literature search for studies published since January 1, 2010. We created a Markov model projecting the lifetime horizon of adults with type 1 diabetes, and performed a budget impact analysis from the perspective of the health care payer. We also conducted interviews and focus group discussions with people who self-manage their type 1 diabetes or support the management of a child with type 1 diabetes. Results Twenty studies were included in the clinical evidence review. Compared with self-monitoring of blood glucose, continuous glucose monitoring improved the percentage of time patients spent in the target glycemic range by 9.6% (95% confidence interval 8.0–11.2) to 10.0% (95% confidence interval 6.75–13.25) and decreased the number of severe hypoglycemic events. Continuous glucose monitoring was associated with higher costs and small increases in health benefits (quality-adjusted life-years). Incremental cost-effectiveness ratios (ICERs) ranged from $592,206 to $1,108,812 per quality-adjusted life-year gained in analyses comparing four continuous glucose monitoring

  2. Continuous Monitoring of Glucose for Type 1 Diabetes: A Health Technology Assessment.

    Science.gov (United States)

    2018-01-01

    Type 1 diabetes is a condition in which the pancreas produces little or no insulin. People with type 1 diabetes must manage their blood glucose levels by monitoring the amount of glucose in their blood and administering appropriate amounts of insulin via injection or an insulin pump. Continuous glucose monitoring may be beneficial compared to self-monitoring of blood glucose using a blood glucose meter. It provides insight into a person's blood glucose levels on a continuous basis, and can identify whether blood glucose levels are trending up or down. We conducted a health technology assessment, which included an evaluation of clinical benefit, value for money, and patient preferences related to continuous glucose monitoring. We compared continuous glucose monitoring with self-monitoring of blood glucose using a finger-prick and a blood glucose meter. We performed a systematic literature search for studies published since January 1, 2010. We created a Markov model projecting the lifetime horizon of adults with type 1 diabetes, and performed a budget impact analysis from the perspective of the health care payer. We also conducted interviews and focus group discussions with people who self-manage their type 1 diabetes or support the management of a child with type 1 diabetes. Twenty studies were included in the clinical evidence review. Compared with self-monitoring of blood glucose, continuous glucose monitoring improved the percentage of time patients spent in the target glycemic range by 9.6% (95% confidence interval 8.0-11.2) to 10.0% (95% confidence interval 6.75-13.25) and decreased the number of severe hypoglycemic events.Continuous glucose monitoring was associated with higher costs and small increases in health benefits (quality-adjusted life-years). Incremental cost-effectiveness ratios (ICERs) ranged from $592,206 to $1,108,812 per quality-adjusted life-year gained in analyses comparing four continuous glucose monitoring interventions to usual care

  3. Is Continuous Glucose Monitoring Underappreciated in the UK?

    Science.gov (United States)

    Parkin, Christopher G; Holloway, Melissa; Truesdell, Jeffrey; C Walker, Tomas

    2017-08-01

    Information about continuous glucose monitoring (CGM) use in the UK is limited. We conducted an online survey of a representative sample of current CGM users in England, Scotland and Wales to address this deficit. The 29-item online survey was conducted between 29 December 2016 and 25 January 2017. Persons with type 1 diabetes (T1D) and caregivers of T1D children/adolescents were recruited from mailing lists, using Nielsen and Harris Polling databases. 315 patients and caregivers responded to the survey - 170 adult patients and 145 caregivers. Among respondents, 144 received full funding for CGM use, 72 received partial funding and 83 received no funding. Most reported improvements in glycated haemoglobin (HbA1c) (67.0%), fewer hypoglycaemia episodes (70.2%), improved hypoglycaemia awareness (77.5%) and better diabetes management (92.4%). Self-funders reported significantly higher CGM use (76.1%) than those who were fully funded (58.9%) and/or partially funded (65.9%), p=0.0008. Fewer than 50% of all respondents reported receiving guidance in interpreting CGM data from their diabetes care team; 30.1% of self-funders reported receiving no CGM support from their diabetes team compared with fully funded (2.8%) and partially funded (1.4%) respondents, p<0.0001. Patients with T1D and their caregivers are realising benefits from CGM use but are largely unsupported by the UK healthcare system.

  4. Design of a prospective clinical study on the agreement between the Continuous GlucoseMonitor, a novel device for CONTinuous ASSessment of blood GLUcose levels, and the RAPIDLab® 1265 blood gas analyser: The CONTASSGLU study.

    Science.gov (United States)

    Zimmermann, Johannes B; Lehmann, Monika; Hofer, Stefan; Hüsing, Johannes; Alles, Catharina; Werner, Jens; Stiller, Jürgen; Künnecke, Wolfgang; Luntz, Steffen; Motsch, Johann; Weigand, Markus A

    2012-09-22

    Although a device is needed to continuously measure blood glucose levels within an intensive care setting, and several large-scale prospective studies have shown that patients might benefit from intensive insulin, potassium, or glucose therapy during intensive care, no devices are currently available to continuously assess blood glucose levels in critically ill patients. We conceived the study described here to evaluate the clinical use of the Continuous Glucose Monitor (CGM) performed via a central vein, and to determine the impact of phenomena, such as drift and shift, on the agreement between the CGM and a RAPIDLab® 1265 blood gas analyser (BGA). In the CONTinuous ASSessment of blood GLUcose (CONTASSGLU) study, up to 130 patients under intensive care will be fitted with the CGM, an ex vivo device that continuously measures blood glucose and lactate levels. Readings from the device taken 8 h after initial placement and calibration will be compared with values measured by a BGA. For this study, we chose the BGA as it is an established standard point-of-care device, instead of the devices used in certified central laboratories. Nevertheless, we will also independently compare the results from the point-of-care BGA with those determined by a central laboratory-based device. Blood samples will be collected from each patient from the same site in which the CGM will measure blood glucose. Consequently, each participant will serve as their own control, and no randomisation is necessary. The 95% limits of agreement and the corresponding confidence intervals will be calculated and compared with a prespecified clinically acceptable relative difference of 20%. Several attempts have been made to develop a device to continuously measure blood glucose levels within an intensive care setting or to use the devices that were originally designed for diabetes management, as several of these devices are already available. However, none of these devices were successful in

  5. Design of a prospective clinical study on the agreement between the Continuous GlucoseMonitor, a novel device for CONTinuous ASSessment of blood GLUcose levels, and the RAPIDLab® 1265 blood gas analyser: The CONTASSGLU study

    Directory of Open Access Journals (Sweden)

    Zimmermann Johannes B

    2012-09-01

    Full Text Available Abstract Background Although a device is needed to continuously measure blood glucose levels within an intensive care setting, and several large-scale prospective studies have shown that patients might benefit from intensive insulin, potassium, or glucose therapy during intensive care, no devices are currently available to continuously assess blood glucose levels in critically ill patients. We conceived the study described here to evaluate the clinical use of the Continuous Glucose Monitor (CGM performed via a central vein, and to determine the impact of phenomena, such as drift and shift, on the agreement between the CGM and a RAPIDLab® 1265 blood gas analyser (BGA. Methods/design In the CONTinuous ASSessment of blood GLUcose (CONTASSGLU study, up to 130 patients under intensive care will be fitted with the CGM, an ex vivo device that continuously measures blood glucose and lactate levels. Readings from the device taken 8 h after initial placement and calibration will be compared with values measured by a BGA. For this study, we chose the BGA as it is an established standard point-of-care device, instead of the devices used in certified central laboratories. Nevertheless, we will also independently compare the results from the point-of-care BGA with those determined by a central laboratory-based device. Blood samples will be collected from each patient from the same site in which the CGM will measure blood glucose. Consequently, each participant will serve as their own control, and no randomisation is necessary. The 95% limits of agreement and the corresponding confidence intervals will be calculated and compared with a prespecified clinically acceptable relative difference of 20%. Discussion Several attempts have been made to develop a device to continuously measure blood glucose levels within an intensive care setting or to use the devices that were originally designed for diabetes management, as several of these devices are already

  6. The use of two continuous glucose sensors during and after surgery

    NARCIS (Netherlands)

    Vriesendorp, T. M.; DeVries, J. H.; Holleman, F.; Dzoljic, M.; Hoekstra, J. B. L.

    2005-01-01

    BACKGROUND: Maintaining plasma glucose between 80 and 120 mg/dL is beneficial for patients admitted to a surgical intensive care unit, but requires frequent glucose monitoring to ensure adequacy of treatment and detection of hypoglycemia. We examined whether continuous glucose sensing is feasible

  7. Clinical assessment of blood glucose homeostasis in horses: comparison of a continuous glucose monitoring system with a combined intravenous glucose and insulin test protocol.

    Science.gov (United States)

    Johnson, P J; Wiedmeyer, C E; LaCarrubba, A; Messer, N T; Dingfelder, H A; Cogswell, A M; Amorim, J R R; Ganjam, V K

    2011-01-01

    The combined glucose-insulin test (CGIT) is helpful for evaluating insulin sensitivity. A continuous glucose monitoring system (CGMS) reports changes in interstitial glucose concentrations as they occur in the blood. Use of the CGMS minimizes animal contact and may be useful when performing a CGIT. Results obtained using a CGMS are useful for the evaluation of glucose responses during the evaluation of insulin sensitivity in equids. Seven mature, obese ponies. Ponies were equipped with CGMS for determination of interstitial glucose concentrations. Glucose (150 mg/kg, i.v.) and insulin (0.1 U/kg, i.v.) were administered and blood glucose concentrations determined at (minutes after time zero) 1, 5, 15, 25, 35, 45, 60, 75, 90, 105, and 120 with a hand-held glucometer. Blood chemistry results were compared with simultaneously obtained results using CGMS. Concordance coefficients determined for comparison of blood glucose concentrations determined by a hand-held glucometer and those determined by CGMS after the zero time point were 0.623, 0.764, 0.834, 0.854, and 0.818 (for delays of 0, 5, 10, 15, and 20 minutes, respectively). Interstitial glucose concentrations obtained by the CGMS compared favorably to blood glucose concentrations. CGMS may be useful for assessment of glucose dynamics in the CGIT. Copyright © 2010 by the American College of Veterinary Internal Medicine.

  8. Glucose monitoring technologies - complementary or competitive? Role of continuous glucose monitoring versus flash glucose monitoring versus self-monitoring of blood glucose

    Directory of Open Access Journals (Sweden)

    Jothydev Kesavadev

    2017-01-01

    Full Text Available We have numerous technologies that can help keep a close watch on an individual's glycaemic status and thereby assist in developing successful diabetes management strategies. For more than five decades, self-monitoring of blood glucose (SMBG has remained as the gold standard tool to manage glycaemic status and has gained huge acceptance. Rigorous research further led to the development of more and more advanced technologies such as continuous glucose monitoring and flash glucose monitoring. These novel technologies are more promising in terms of revealing the complete glycaemic picture and even more user-friendly than the already established blood glucosemetres. However, they are yet to achieve remarkable accuracy and performance. There will also be a subgroup of patients who will be using these technologies only occasionally and thus will definitely require SMBG at other times. Again, with regard to the retrospective ones, glucose data can be obtained only once they are downloaded to the system and hence, real-time values will still have to be procured with the help of an SMBG. In future when the accuracy and performance of these newer technologies become equal to that of glucometres, the glucometres might vanish. Until then, all these technologies will definitely go hand-in-hand and supplement each other than competing each other. All the related literature were retrieved from various databases including 'PubMed' and 'Cochrane Database of Systematic Reviews' using specific search terms that were relevant to the topics discussed this manuscript.

  9. Evaluation of a Novel Glucose Area Under the Curve (AUC) Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring.

    Science.gov (United States)

    Ugi, Satoshi; Maegawa, Hiroshi; Morino, Katsutaro; Nishio, Yoshihiko; Sato, Toshiyuki; Okada, Seiki; Kikkawa, Yasuo; Watanabe, Toshihiro; Nakajima, Hiromu; Kashiwagi, Atsunori

    2016-08-01

    Management of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC) using minimally invasive interstitial fluid extraction technology (MIET) for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM) by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration. Twenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels. AUC predicted by MIET correlated well with that measured by CGM (r=0.93). Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%±10.2% for 2 hours and 11.1%±7.9% for 4 hours), indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours. Our system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration.

  10. Analysis of Continuous Glucose Monitoring in Pregnant Women With Diabetes

    DEFF Research Database (Denmark)

    Law, Graham R; Ellison, George T H; Secher, Anna L

    2015-01-01

    with diabetes. RESEARCH DESIGN AND METHODS: Functional data analysis (FDA) was applied to 1.68 million glucose measurements from 759 measurement episodes, obtained from two previously published randomized controlled trials of CGM in pregnant women with diabetes. A total of 117 women with type 1 diabetes (n = 89...... developed LGA. LGA was associated with lower mean glucose (7.0 vs. 7.1 mmol/L; P FDA showed that glucose was significantly lower midmorning (0900-1100 h) and early...... evening (1900-2130 h) in trimester 1, significantly higher early morning (0330-0630 h) and throughout the afternoon (1130-1700 h) in trimester 2, and significantly higher during the evening (2030-2330 h) in trimester 3 in women whose infants were LGA. CONCLUSIONS: FDA of CGM data identified specific times...

  11. Use of a real time continuous glucose monitoring system as an educational tool for patients with gestational diabetes.

    Science.gov (United States)

    Alfadhli, Eman; Osman, Eman; Basri, Taghreed

    2016-01-01

    Women with gestational diabetes mellitus (GDM) are required to control their blood glucose shortly after GDM diagnosis to minimize adverse pregnancy outcomes. A real time-continuous glucose monitoring system (RT-CGMS) provides the patient with continuous information about the alterations in levels of the blood glucose. This visibility may empower the patient to modify her lifestyle and engage in therapeutic management. The aim of this study was to determine whether a single application of RT-CGMS to pregnant women shortly after GDM diagnosis is useful as an educational and motivational tool. This study was a prospective open label randomized controlled study conducted at Maternity and Children Hospital, Medina, Saudi Arabia. A total of 130 pregnant women with GDM were randomised to either blood glucose self-monitor alone (SMBG group) (n = 62) or in addition to SMBG, patients wore a Guardian(®) REAL-Time Continuous Glucose Monitoring System (Medtronic MiniMed) once for 3-7 days, within 2 weeks of GDM diagnosis (RT-CGMS group) (n = 68). The primary outcomes were maternal glycemic control and pregnancy outcomes. Secondary outcomes were the changes in parameters of glucose variability, which includes mean sensor readings, standard deviation (SD) of blood glucose, and area under the curve for hyper and hypoglycaemia at the end of the RT-CGMS application. HbA1c, mean fasting and postprandial glucose levels were similar in both groups at the end of the pregnancy. Pregnancy outcomes were comparable. However, there was significant improvement in the parameters of glucose variability on the last day of sensor application; both mean glucose and the SD of mean glycaemia were reduced significantly; P = 0.016 and P = 0.034, respectively. The area under the curve for hyper and hypoglycaemia were improved, however, the results were not statistically significant. Although a single application of RT-CGMS shortly after GDM diagnosis is helpful as an educational tool, it

  12. Evaluation of a Novel Glucose Area Under the Curve (AUC Monitoring System: Comparison with the AUC by Continuous Glucose Monitoring

    Directory of Open Access Journals (Sweden)

    Satoshi Ugi

    2016-07-01

    Full Text Available BackgroundManagement of postprandial hyperglycemia is a key aspect in diabetes treatment. We developed a novel system to measure glucose area under the curve (AUC using minimally invasive interstitial fluid extraction technology (MIET for simple monitoring of postprandial glucose excursions. In this study, we evaluated the relationship between our system and continuous glucose monitoring (CGM by comparing glucose AUC obtained using MIET with that obtained using CGM for a long duration.MethodsTwenty diabetic inpatients wearing a CGM system were enrolled. For MIET measurement, a plastic microneedle array was applied to the skin as pretreatment, and hydrogels were placed on the pretreated area to collect interstitial fluid. Hydrogels were replaced every 2 or 4 hours and AUC was predicted on the basis of glucose and sodium ion levels.ResultsAUC predicted by MIET correlated well with that measured by CGM (r=0.93. Good performances of both consecutive 2- and 4-hour measurements were observed (measurement error: 11.7%±10.2% for 2 hours and 11.1%±7.9% for 4 hours, indicating the possibility of repetitive measurements up to 8 hours. The influence of neither glucose fluctuation nor average glucose level over the measurement accuracy was observed through 8 hours.ConclusionOur system showed good relationship with AUC values from CGM up to 8 hours, indicating that single pretreatment can cover a large portion of glucose excursion in a day. These results indicated possibility of our system to contribute to convenient monitoring of glucose excursions for a long duration.

  13. Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System.

    Science.gov (United States)

    McGarraugh, Geoffrey; Bergenstal, Richard

    2009-03-01

    The objective of the analysis was to compare detection of hypoglycemic episodes (glucose 15 min) with the FreeStyle Navigator Continuous Glucose Monitoring System (FSN-CGM) (Abbott Diabetes Care, Alameda, CA) alarms to detection with traditional finger stick testing at an average frequency of eight tests per day. The performance of FSN-CGM alarms was evaluated in a clinic setting using 58 subjects with type 1 diabetes mellitus (T1DM) monitoring interstitial glucose concentration over a 5-day period compared to reference YSI measurements (instrument manufactured by YSI, Yellow Springs, OH) at 15-min intervals. Finger stick glucose testing was evaluated in the home environment with 91 subjects with TIDM monitoring with the blood glucose meter integrated into the FreeStyle Navigator (FSN-BG) over a 20-day period. The reference was FSN-CGM with results masked from the subjects. Blood glucose values glucose was <= 85 mg/dL 77.2% of the time. In the home environment, the average FSN-BG testing frequency was 7.9 tests per day. Hypoglycemia was verified within +/- 30 min by FSN-BG measurements <= 85 mg/dL at a rate of 27.5%. Even with a high rate of FSN-BG testing, hypoglycemia detected by FSN-CGM was verified by patients with T1DM very infrequently. A high rate of hypoglycemia detection with a moderate rate of unnecessary alarms can be attained using FSN-CGM.

  14. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System

    NARCIS (Netherlands)

    Kropff, Jort; van Steen, Sigrid C.; deGraaff, Peter; Chan, Man W.; van Amstel, Rombout B. E.; DeVries, J. Hans

    2017-01-01

    Background: Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. Methods: We evaluated 21 individuals with type 1 diabetes

  15. Relationship between fluctuations in glucose levels measured by continuous glucose monitoring and vascular endothelial dysfunction in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Torimoto Keiichi

    2013-01-01

    Full Text Available Abstract Background Fluctuations in blood glucose level cause endothelial dysfunction and play a critical role in onset and/or progression of atherosclerosis. We hypothesized that fluctuation in blood glucose levels correlate with vascular endothelial dysfunction and that this relationship can be assessed using common bedside medical devices. Methods Fluctuations in blood glucose levels were measured over 24 hours by continuous glucose monitoring (CGM on admission day 2 in 57 patients with type 2 diabetes mellitus. The reactive hyperemia index (RHI, an index of vascular endothelial function, was measured using peripheral arterial tonometry (EndoPAT on admission day 3. Results The natural logarithmic-scaled RHI (L_RHI correlated with SD (r=−0.504; PPP=0.001 and percentage of time ≥200 mg/dl (r=−0.292; P=0.028. In 12 patients with hypoglycemia, L_RHI also correlated with the percentage of time at hypoglycemia (r=−0.589; P=0.044. L_RHI did not correlate with HbA1c or fasting plasma glucose levels. Furthermore, L_RHI did not correlate with LDL cholesterol, HDL cholesterol, and triglyceride levels or with systolic and diastolic blood pressures. Finally, multivariate analysis identified MAGE as the only significant determinant of L_RHI. Conclusions Fluctuations in blood glucose levels play a significant role in vascular endothelial dysfunction in type 2 diabetes. Trial registration UMIN000007581

  16. Continuous glucose and exhaled breath analysis in the Intensive Care Unit

    NARCIS (Netherlands)

    Leopold, J.H.

    2017-01-01

    This thesis covers several topics including studies on the accuracy of continuous glucose measurement (CGM) devices in the Intensive Care Unit (ICU). In addition, it is investigated whether an electronic nose (eNose) can be used to predict blood glucose levels in mechanically ventilated ICU

  17. [Design and implementation of real-time continuous glucose monitoring instrument].

    Science.gov (United States)

    Huang, Yonghong; Liu, Hongying; Tian, Senfu; Jia, Ziru; Wang, Zi; Pi, Xitian

    2017-12-01

    Real-time continuous glucose monitoring can help diabetics to control blood sugar levels within the normal range. However, in the process of practical monitoring, the output of real-time continuous glucose monitoring system is susceptible to glucose sensor and environment noise, which will influence the measurement accuracy of the system. Aiming at this problem, a dual-calibration algorithm for the moving-window double-layer filtering algorithm combined with real-time self-compensation calibration algorithm is proposed in this paper, which can realize the signal drift compensation for current data. And a real-time continuous glucose monitoring instrument based on this study was designed. This real-time continuous glucose monitoring instrument consisted of an adjustable excitation voltage module, a current-voltage converter module, a microprocessor and a wireless transceiver module. For portability, the size of the device was only 40 mm × 30 mm × 5 mm and its weight was only 30 g. In addition, a communication command code algorithm was designed to ensure the security and integrity of data transmission in this study. Results of experiments in vitro showed that current detection of the device worked effectively. A 5-hour monitoring of blood glucose level in vivo showed that the device could continuously monitor blood glucose in real time. The relative error of monitoring results of the designed device ranged from 2.22% to 7.17% when comparing to a portable blood meter.

  18. Impact of retrospective calibration algorithms on hypoglycemia detection in newborn infants using continuous glucose monitoring.

    Science.gov (United States)

    Signal, Matthew; Le Compte, Aaron; Harris, Deborah L; Weston, Philip J; Harding, Jane E; Chase, J Geoffrey

    2012-10-01

    Neonatal hypoglycemia is common and may cause serious brain injury. Diagnosis is by blood glucose (BG) measurements, often taken several hours apart. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing the number of BG measurements. Calibration algorithms convert sensor signals into CGM output. Thus, these algorithms directly affect measures used to quantify hypoglycemia. This study was designed to quantify the effects of recalibration and filtering of CGM data on measures of hypoglycemia (BG neonates. CGM data from 50 infants were recalibrated using an algorithm that explicitly recognized the high-accuracy BG measurements available in this study. CGM data were analyzed as (1) original CGM output, (2) recalibrated CGM output, (3) recalibrated CGM output with postcalibration median filtering, and (4) recalibrated CGM output with precalibration median filtering. Hypoglycemia was classified by number of episodes, duration, severity, and hypoglycemic index. Recalibration increased the number of hypoglycemic events (from 161 to 193), hypoglycemia duration (from 2.2% to 2.6%), and hypoglycemic index (from 4.9 to 7.1 μmol/L). Median filtering postrecalibration reduced hypoglycemic events from 193 to 131, with little change in duration (from 2.6% to 2.5%) and hypoglycemic index (from 7.1 to 6.9 μmol/L). Median filtering prerecalibration resulted in 146 hypoglycemic events, a total duration of hypoglycemia of 2.6%, and a hypoglycemic index of 6.8 μmol/L. Hypoglycemia metrics, especially counting events, are heavily dependent on CGM calibration BG error, and the calibration algorithm. CGM devices tended to read high at lower levels, so when high accuracy calibration measurements are available it may be more appropriate to recalibrate the data.

  19. [CGM-Continuous Glucose Monitoring--Statement of the Austrian Diabetes Association].

    Science.gov (United States)

    Schütz-Fuhrmann, Ingrid; Rami-Merhar, Birgit; Hofer, Sabine; Stadler, Marietta; Bischof, Martin; Zlamal-Fortunat, Sandra; Laimer, Markus; Weitgasser, Raimund; Prager, Rudolf

    2016-04-01

    This position statement represents the recommendations of the Austrian Diabetes Association regarding the clinical diagnostic and therapeutic application, safety and benefits of continuous subcutaneous glucose monitoring systems in patients with diabetes mellitus, based on current evidence.

  20. [CGM-continuous glucose monitoring - statement of the Austrian Diabetes Association].

    Science.gov (United States)

    Schütz-Fuhrmann, Ingrid; Schober, Edith; Rami, Birgit; Stadler, Marietta; Bischof, Martin; Fortunat, Sandra; Laimer, Markus; Weitgasser, Raimund; Prager, Rudolf

    2012-12-01

    This position statement represents the recommendations of the Austrian Diabetes Association regarding the clinical diagnostic and therapeutic application, safety and benefits of continuous subcutaneous glucose monitoring systems in patients with diabetes mellitus, based on current evidence.

  1. Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes.

    Science.gov (United States)

    Slattery, David; Choudhary, Pratik

    2017-05-01

    With the emphasis on intensive management of type 1 diabetes, data from studies support frequent monitoring of glucose levels to improve glycemic control and reduce glucose variability, which can be related to an increase in macro and microvascular complications. However, few perform capillary blood glucose that frequently. There are currently two available alternatives that this review will discuss, continuous glucose monitoring (CGM) and flash glucose monitoring. CGM has become an important diagnostic and therapeutic option in optimizing diabetes management. CGM systems are now more accurate, smaller, and easier to use compared to original models. Randomized controlled trials (RCTs) have demonstrated that CGM can improve Hemoglobin A1c (HbA1C) and reduce glucose variability in both continuous subcutaneous insulin infusion and multiple daily injection users. When used in an automated "insulin-suspend" system, reduced frequency of hypoglycemia and shorter time spent in hypoglycemic range have been demonstrated. Despite the potential benefits CGM has to offer in clinical practice, concerns exist on the accuracy of these devices and patient compliance with therapy, which may prevent the true clinical benefit of CGM being achieved, as observed in RCTs. Flash glucose monitoring systems FreeStyle ® Libre™ (Abbott Diabetes Care, Alameda, CA) are as accurate as many CGM systems available and have the added benefit of being factory calibrated. Studies have shown that flash glucose monitoring systems are very well tolerated by patients and effectively reduce glucose variability, increasing time in range.

  2. Self-reported discrimination, diabetes distress, and continuous blood glucose in women with type 2 diabetes.

    Science.gov (United States)

    Wagner, Julie A; Tennen, Howard; Feinn, Richard; Osborn, Chandra Y

    2015-04-01

    We investigated whether self-reported racial discrimination was associated with continuous glucose levels and variability in individuals with diabetes, and whether diabetes distress mediated these associations. Seventy-four Black and White women with type 2 diabetes completed the Experience of Discrimination scale, a measure of lifetime racial discrimination, and the Problem Areas in Diabetes, a measure of diabetes distress. Participants wore a continuous glucose monitor for 24 h after 8 h of fasting, a standard meal, and a 4-h run in period. Higher discrimination predicted higher continuous mean glucose and higher standard deviation of glucose. For both mean and standard deviation of glucose, a race × discrimination interaction indicated a stronger relationship between discrimination and glucose for Whites than for Blacks. Diabetes distress mediated the discrimination-mean glucose relationship. Whites who report discrimination may be uniquely sensitive to distress. These preliminary findings suggest that racial discrimination adversely affects glucose control in women with diabetes, and does so indirectly through diabetes distress. Diabetes distress may be an important therapeutic target to reduce the ill effects of racial discrimination in persons with diabetes.

  3. Continuous non-invasive blood glucose monitoring by spectral image differencing method

    Science.gov (United States)

    Huang, Hao; Liao, Ningfang; Cheng, Haobo; Liang, Jing

    2018-01-01

    Currently, the use of implantable enzyme electrode sensor is the main method for continuous blood glucose monitoring. But the effect of electrochemical reactions and the significant drift caused by bioelectricity in body will reduce the accuracy of the glucose measurements. So the enzyme-based glucose sensors need to be calibrated several times each day by the finger-prick blood corrections. This increases the patient's pain. In this paper, we proposed a method for continuous Non-invasive blood glucose monitoring by spectral image differencing method in the near infrared band. The method uses a high-precision CCD detector to switch the filter in a very short period of time, obtains the spectral images. And then by using the morphological method to obtain the spectral image differences, the dynamic change of blood sugar is reflected in the image difference data. Through the experiment proved that this method can be used to monitor blood glucose dynamically to a certain extent.

  4. Design of a prospective clinical study on the agreement between the Continuous GlucoseMonitor, a novel device for CONTinuous ASSessment of blood GLUcose levels, and the RAPIDLab® 1265 blood gas analyser: The CONTASSGLU study

    OpenAIRE

    Zimmermann Johannes B; Lehmann Monika; Hofer Stefan; Hüsing Johannes; Alles Catharina; Werner Jens; Stiller Jürgen; Künnecke Wolfgang; Luntz Steffen; Motsch Johann; Weigand Markus A

    2012-01-01

    Abstract Background Although a device is needed to continuously measure blood glucose levels within an intensive care setting, and several large-scale prospective studies have shown that patients might benefit from intensive insulin, potassium, or glucose therapy during intensive care, no devices are currently available to continuously assess blood glucose levels in critically ill patients. We conceived the study described here to evaluate the clinical use of the Continuous Glucose Monitor (C...

  5. Using meta-differential evolution to enhance a calculation of a continuous blood glucose level.

    Science.gov (United States)

    Koutny, Tomas

    2016-09-01

    We developed a new model of glucose dynamics. The model calculates blood glucose level as a function of transcapillary glucose transport. In previous studies, we validated the model with animal experiments. We used analytical method to determine model parameters. In this study, we validate the model with subjects with type 1 diabetes. In addition, we combine the analytic method with meta-differential evolution. To validate the model with human patients, we obtained a data set of type 1 diabetes study that was coordinated by Jaeb Center for Health Research. We calculated a continuous blood glucose level from continuously measured interstitial fluid glucose level. We used 6 different scenarios to ensure robust validation of the calculation. Over 96% of calculated blood glucose levels fit A+B zones of the Clarke Error Grid. No data set required any correction of model parameters during the time course of measuring. We successfully verified the possibility of calculating a continuous blood glucose level of subjects with type 1 diabetes. This study signals a successful transition of our research from an animal experiment to a human patient. Researchers can test our model with their data on-line at https://diabetes.zcu.cz. Copyright © 2016 The Author. Published by Elsevier Ireland Ltd.. All rights reserved.

  6. Optical biosensor optimized for continuous in-line glucose monitoring in animal cell culture.

    Science.gov (United States)

    Tric, Mircea; Lederle, Mario; Neuner, Lisa; Dolgowjasow, Igor; Wiedemann, Philipp; Wölfl, Stefan; Werner, Tobias

    2017-09-01

    Biosensors for continuous glucose monitoring in bioreactors could provide a valuable tool for optimizing culture conditions in biotechnological applications. We have developed an optical biosensor for long-term continuous glucose monitoring and demonstrated a tight glucose level control during cell culture in disposable bioreactors. The in-line sensor is based on a commercially available oxygen sensor that is coated with cross-linked glucose oxidase (GOD). The dynamic range of the sensor was tuned by a hydrophilic perforated diffusion membrane with an optimized permeability for glucose and oxygen. The biosensor was thoroughly characterized by experimental data and numerical simulations, which enabled insights into the internal concentration profile of the deactivating by-product hydrogen peroxide. The simulations were carried out with a one-dimensional biosensor model and revealed that, in addition to the internal hydrogen peroxide concentration, the turnover rate of the enzyme GOD plays a crucial role for biosensor stability. In the light of this finding, the glucose sensor was optimized to reach a long functional stability (>52 days) under continuous glucose monitoring conditions with a dynamic range of 0-20 mM and a response time of t 90  ≤ 10 min. In addition, we demonstrated that the sensor was sterilizable with beta and UV irradiation and only subjected to minor cross sensitivity to oxygen, when an oxygen reference sensor was applied. Graphical abstract Measuring setup of a glucose biosensor in a shake flask for continuous glucose monitoring in mammalian cell culture.

  7. Application of the Continuous-Discrete Extended Kalman Filter for Fault Detection in Continuous Glucose Monitors for Type 1 Diabetes

    DEFF Research Database (Denmark)

    Mahmoudi, Zeinab; Boiroux, Dimitri; Hagdrup, Morten

    2016-01-01

    The purpose of this study is the online detection of faults and anomalies of a continuous glucose monitor (CGM). We simulated a type 1 diabetes patient using the Medtronic virtual patient model. The model is a system of stochastic differential equations and includes insulin pharmacokinetics...

  8. Patient satisfaction and barriers to initiating real-time continuous glucose monitoring in early pregnancy in women with diabetes

    DEFF Research Database (Denmark)

    Secher, A L; Madsen, A B; Nielsen, Lene Ringholm

    2012-01-01

    of initial monitoring). Ten women (15%) did not wish to use continuous glucose monitoring again in pregnancy. Main causes behind early removal of continuous glucose monitoring were self-reported skin irritation, technical problems and continuous glucose monitoring inaccuracy. No differences were found......Aim: To evaluate self-reported satisfaction and barriers to initiating real-time continuous glucose monitoring in early pregnancy among women with pregestational diabetes. Methods: Fifty-four women with Type 1 diabetes and 14 women with Type 2 diabetes were offered continuous glucose monitoring...

  9. Numerical and clinical precision of continuous glucose monitoring in Colombian patients treated with insulin infusion pump with automated suspension in hypoglycemia.

    Science.gov (United States)

    Gómez, Ana M; Marín Sánchez, Alejandro; Muñoz, Oscar M; Colón Peña, Christian Alejandro

    2015-12-01

    Insulin pump therapy associated with continuous glucose monitoring has shown a positive clinical impact on diabetes control and reduction of hypoglycemia episodes. There are descriptions of the performance of this device in other populations, but its precision and accuracy in Colombia and Latin America are unknown, especially in the routine outpatient setting. Data from 33 type 1 and type 2 diabetes patients with sensor-augmented pump therapy with threshold suspend automation, MiniMed Paradigm® Veo™ (Medtronic, Northridge, California), managed at Hospital Universitario San Ignacio (Bogotá, Colombia) and receiving outpatient treatment, were analyzed. Simultaneous data from continuous glucose monitoring and capillary blood glucose were compared, and their precision and accuracy were calculating with different methods, including Clarke error grid. Analyses included 2,262 continuous glucose monitoring -reference paired glucose values. A mean absolute relative difference of 20.1% was found for all measurements, with a value higher than 23% for glucose levels ≤75mg/dL. Global compliance with the ISO criteria was 64.9%. It was higher for values >75mg/dl (68.3%, 1,308 of 1,916 readings), than for those ≤ 75mg/dl (49.4%, 171 of 346 readings). Clinical accuracy, as assessed by the Clarke error grid, showed that 91.77% of data were within the A and B zones (75.6% in hypoglycemia). A good numerical accuracy was found for continuous glucose monitoring in normo and hyperglycemia situations, with low precision in hypoglycemia. The clinical accuracy of the device was adequate, with no significant safety concerns for patients. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  10. Is type 2 diabetes really resolved after laparoscopic sleeve gastrectomy? Glucose variability studied by continuous glucose monitoring.

    Science.gov (United States)

    Capoccia, D; Coccia, F; Guida, A; Rizzello, M; De Angelis, F; Silecchia, G; Leonetti, F

    2015-01-01

    The study was carried out on type 2 diabetic obese patients who underwent laparoscopic sleeve gastrectomy (LSG). Patients underwent regular glycemic controls throughout 3 years and all patients were defined cured from diabetes according to conventional criteria defined as normalization of fasting glucose levels and glycated hemoglobin in absence of antidiabetic therapy. After 3 years of follow-up, Continuous Glucose Monitoring (CGM) was performed in each patient to better clarify the remission of diabetes. In this study, we found that the diabetes resolution after LSG occurred in 40% of patients; in the other 60%, even if they showed a normal fasting glycemia and A1c, patients spent a lot of time in hyperglycemia. During the oral glucose tolerance test (OGTT), we found that 2 h postload glucose determinations revealed overt diabetes only in a small group of patients and might be insufficient to exclude the diagnosis of diabetes in the other patients who spent a lot of time in hyperglycemia, even if they showed a normal glycemia (<140 mg/dL) at 120 minutes OGTT. These interesting data could help clinicians to better individualize patients in which diabetes is not resolved and who could need more attention in order to prevent chronic complications of diabetes.

  11. Continuous glucose monitoring in subcutaneous tissue using factory-calibrated sensors: a pilot study.

    Science.gov (United States)

    Hoss, Udo; Jeddi, Iman; Schulz, Mark; Budiman, Erwin; Bhogal, Claire; McGarraugh, Geoffrey

    2010-08-01

    Commercial continuous subcutaneous glucose monitors require in vivo calibration using capillary blood glucose tests. Feasibility of factory calibration, i.e., sensor batch characterization in vitro with no further need for in vivo calibration, requires a predictable and stable in vivo sensor sensitivity and limited inter- and intra-subject variation of the ratio of interstitial to blood glucose concentration. Twelve volunteers wore two FreeStyle Navigator (Abbott Diabetes Care, Alameda, CA) continuous glucose monitoring systems for 5 days in parallel for two consecutive sensor wears (four sensors per subject, 48 sensors total). Sensors from a prototype sensor lot with a low variability in glucose sensitivity were used for the study. Median sensor sensitivity values based on capillary blood glucose were calculated per sensor and compared for inter- and intra-subject variation. Mean absolute relative difference (MARD) calculation and error grid analysis were performed using a single calibration factor for all sensors to simulate factory calibration and compared to standard fingerstick calibration. Sensor sensitivity variation in vitro was 4.6%, which increased to 8.3% in vivo (P glucose monitoring is feasible with similar accuracy to standard fingerstick calibration. Additional data are required to confirm this result in subjects with diabetes.

  12. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia?

    OpenAIRE

    Thomas, Felicity Louise; Signal, Mathew; Harris, Deborah L.; Weston, Philip J.; Harding, Jane E.; Shaw, Geoffrey M.; Chase, J. Geoffrey

    2014-01-01

    Neonatal hypoglycemia is common and can cause serious brain injury. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing blood glucose (BG) measurements. Calibration algorithms use BG measurements to convert sensor signals into CGM data. Thus, inaccuracies in calibration BG measurements directly affect CGM values and any metrics calculated from them. The aim was to quantify the effect of timing delays and calibration BG measurement errors on hypoglycemia me...

  13. Microcirculation and its relation to continuous subcutaneous glucose sensor accuracy in cardiac surgery patients in the intensive care unit

    NARCIS (Netherlands)

    Siegelaar, Sarah E.; Barwari, Temo; Hermanides, Jeroen; van der Voort, Peter H. J.; Hoekstra, Joost B. L.; DeVries, J. Hans

    2013-01-01

    Continuous glucose monitoring could be helpful for glucose regulation in critically ill patients; however, its accuracy is uncertain and might be influenced by microcirculation. We investigated the microcirculation and its relation to the accuracy of 2 continuous glucose monitoring devices in

  14. High glycemic variability assessed by continuous glucose monitoring after surgical treatment of obesity by gastric bypass.

    Science.gov (United States)

    Hanaire, Helene; Bertrand, Monelle; Guerci, Bruno; Anduze, Yves; Guillaume, Eric; Ritz, Patrick

    2011-06-01

    Obesity surgery elicits complex changes in glucose metabolism that are difficult to observe with discontinuous glucose measurements. We aimed to evaluate glucose variability after gastric bypass by continuous glucose monitoring (CGM) in a real-life setting. CGM was performed for 4.2 ± 1.3 days in three groups of 10 subjects each: patients who had undergone gastric bypass and who were referred for postprandial symptoms compatible with mild hypoglycemia, nonoperated diabetes controls, and healthy controls. The maximum interstitial glucose (IG), SD of IG values, and mean amplitude of glucose excursions (MAGE) were significantly higher in operated patients and in diabetes controls than in healthy controls. The time to the postprandial peak IG was significantly shorter in operated patients (42.8 ± 6.0 min) than in diabetes controls (82.2 ± 11.1 min, P = 0.0002), as were the rates of glucose increase to the peak (2.4 ± 1.6 vs. 1.2 ± 0.3 mg/mL/min; P = 0.041). True hypoglycemia (glucose fasting state and 2 h postmeal. Glucose variability is exaggerated after gastric bypass, combining unusually high and early hyperglycemic peaks and rapid IG decreases. This might account for postprandial symptoms mimicking hypoglycemia but often seen without true hypoglycemia. Early postprandial hyperglycemia might be underestimated if glucose measurements are done 2 h postmeal.

  15. Continuing Education Needs and the Professional Reading of School Library Media Specialists.

    Science.gov (United States)

    Latrobe, Kathy

    1992-01-01

    Reports results of a survey of school library media specialists in Oklahoma regarding continuing education activities and topics. Data are presented on the relative importance of several continuing education activities, percentage of respondents regularly reading specific journals, and continuing education topics ranked by respondents' prioritized…

  16. Towards a continuous glucose monitoring system using tunable quantum cascade lasers

    Science.gov (United States)

    Haase, Katharina; Müller, Niklas; Petrich, Wolfgang

    2018-02-01

    We present a reagent-free approach for long-term continuous glucose monitoring (cgm) of liquid samples using midinfrared absorption spectroscopy. This method could constitute an alternative to enzymatic glucose sensors in order to manage the widespread disease of Diabetes. In order to acquire spectra of the liquid specimen, we use a spectrally tunable external-cavity (EC-) quantum cascade laser (QCL) as radiation source in combination with a fiber-based in vitro sensor setup. Hereby we achieve a glucose sensitivity in pure glucose solutions of 3 mg/dL (RMSEP). Furthermore, the spectral tunability of the EC-QCL enables us to discriminate glucose from other molecules. We exemplify this by detecting glucose among other saccharides with an accuracy of 8 mg/dL (within other monosaccharides, RMSEVC) and 14 mg/dL (within other mono- and disaccharides, RMSECV). Moreover, we demonstrate a characterization of the significance of each wavenumber for an accurate prediction of glucose among other saccharides using an evolutionary algorithm. We show, that by picking 10 distinct wavenumbers we can achieve comparable accuracies to the use of a complete spectrum.

  17. Hypoglycemia in type 2 diabetes patients treated with insulin: the advantages of continuous glucose monitoring

    Directory of Open Access Journals (Sweden)

    Vadim Valer'evich Klimontov

    2014-03-01

    Full Text Available Aims.  To determine the incidence and risk factors for hypoglycemia in elderly insulin-treated type 2 diabetes mellitus (T2DM patients by means of continuous glucose monitoring (CGM. Materials and Methods.  We observed seventy-six hospitalized patients with T2DM, aged 65 to 79 years. Treatment with basal insulin (n=36, premixed insulin (n=12 or basal-bolus insulin regimen (n=28 was followed by metformin (n=44, glimepiride (n=14 and dipeptidyl peptidase-4 inhibitors (n=14. 2-days CGM with retrospective data analysis was performed in all patients. During CGM, three fasting and three 2-h postprandial finger-prick glucose values were obtained daily with portable glucose meter. Results.  Hypoglycemia (identified as blood glucose

  18. Venous, Arterialized-Venous, or Capillary Glucose Reference Measurements for the Accuracy Assessment of a Continuous Glucose Monitoring System.

    Science.gov (United States)

    Kropff, Jort; van Steen, Sigrid C; deGraaff, Peter; Chan, Man W; van Amstel, Rombout B E; DeVries, J Hans

    2017-11-01

    Different reference methods are used for the accuracy assessment of continuous glucose monitoring (CGM) systems. The effect of using venous, arterialized-venous, or capillary reference measurements on CGM accuracy is unclear. We evaluated 21 individuals with type 1 diabetes using a capillary calibrated CGM system. Venous or arterialized-venous reference glucose samples were taken every 15 min at two separate visits and assessed per YSI 2300 STAT Plus. Arterialization was achieved by heated-hand technique. Capillary samples were collected hourly during the venous reference visit. The investigation sequence (venous or arterialized-venous) was randomized. Effectiveness of arterialization was measured by comparing free venous oxygen pressure (PO2) of both visit days. Primary endpoint was the median absolute relative difference (ARD). Median ARD using arterialized-venous reference samples was not different from venous samples (point estimated difference 0.52%, P = 0.181). When comparing the three reference methods, median ARD was also not different over the full glycemic range (venous 9.0% [n = 681], arterialized-venous 8.3% [n = 684], and capillary 8.1% [n = 205], P = 0.216), nor over the separate glucose ranges. Arterialization was successful (PO2 venous 5.4 kPa vs. arterialized-venous 8.9 kPa, P reference measurements did not significantly impact CGM accuracy. Venous reference seems preferable due to its ease of operation.

  19. Could Continuous Glucose Monitoring Facilitate Identifying Diabetes Patients with a Higher Risk of Hypoglycemia during Driving?

    Czech Academy of Sciences Publication Activity Database

    Brož, J.; Doničová, V.; Brabec, Marek; Janíčková Žďárská, D.; Polák, J.

    2013-01-01

    Roč. 7, č. 6 (2013), s. 1644-1645 ISSN 1932-2968 Institutional support: RVO:67985807 Keywords : continuous glucose monitoring * driving * hypoglycemia * insulin pump * prevention * type 1 diabetes mellitus Subject RIV: BB - Applied Statistics, Operational Research http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3876343/

  20. Use of an Intravascular Fluorescent Continuous Glucose Sensor in ICU Patients

    NARCIS (Netherlands)

    Strasma, Paul J.; Finfer, Simon; Flower, Oliver; Hipszer, Brian; Kosiborod, Mikhail; Macken, Lewis; Sechterberger, Marjolein; van der Voort, Peter H. J.; DeVries, J. Hans; Joseph, Jeffrey I.

    2015-01-01

    Hyperglycemia and hypoglycemia are associated with adverse clinical outcomes in intensive care patients. In product development studies at 4 ICUs, the safety and performance of an intravascular continuous glucose monitoring (IV-CGM) system was evaluated in 70 postsurgical patients. The GluCath

  1. Slow ultrafiltration for continuous in vivo sampling : application for glucose and lactate in man

    NARCIS (Netherlands)

    Tiessen, RG; Kaptein, WA; Venema, K; Korf, J

    1999-01-01

    Background: An ultrafiltration (UF) technique was developed for continuous subcutaneous (s.c.) sampling and on-line analysis of absolute glucose and lactate concentrations in tissue. The relation between subcutaneous and blood concentrations was studied in men, because a subcutaneous monitoring

  2. Accuracy and reliability of continuous glucose monitoring systems: a head-to-head comparison

    NARCIS (Netherlands)

    Luijf, Yoeri M.; Mader, Julia K.; Doll, Werner; Pieber, Thomas; Farret, Anne; Place, Jerome; Renard, Eric; Bruttomesso, Daniela; Filippi, Alessio; Avogaro, Angelo; Arnolds, Sabine; Benesch, Carsten; Heinemann, Lutz; DeVries, J. Hans

    2013-01-01

    This study assessed the accuracy and reliability of three continuous glucose monitoring (CGM) systems. We studied the Animas® (West Chester, PA) Vibe™ with Dexcom® (San Diego, CA) G4™ version A sensor (G4A), the Abbott Diabetes Care (Alameda, CA) Freestyle® Navigator I (NAV), and the Medtronic

  3. Continuous glucose monitoring-enabled insulin-pump therapy in diabetic pregnancy

    DEFF Research Database (Denmark)

    Secher, Anna L; Schmidt, Signe; Nørgaard, Kirsten

    2010-01-01

    We describe the feasibility of continuous glucose monitoring (CGM)-enabled insulin-pump therapy during pregnancy in a woman with type 1 diabetes, who was treated with CGM-enabled insulin-pump therapy in her third pregnancy. During her first pregnancy, the woman was treated with multiple daily inj...

  4. Continuous glucose monitoring system and new era of early diagnosis of diabetes in high risk groups

    Directory of Open Access Journals (Sweden)

    Ashraf Soliman

    2014-01-01

    Full Text Available Continuous glucose monitoring (CGM systems are an emerging technology that allows frequent glucose measurements to monitor glucose trends in real time. Their use as a diagnostic tool is still developing and appears to be promising. Combining intermittent glucose self-monitoring (SGM and CGM combines the benefits of both. Significant improvement in the treatment modalities that may prevent the progress of prediabetes to diabetes have been achieved recently and dictates screening of high risk patients for early diagnosis and management of glycemic abnormalities. The use of CGMS in the diagnosis of early dysglycemia (prediabetes especially in high risk patients appears to be an attractive approach. In this review we searched the literature to investigate the value of using CGMS as a diagnostic tool compared to other known tools, namely oral glucose tolerance test (OGTT and measurement of glycated hemoglobin (HbA1C in high risk groups. Those categories of patients include adolescents and adults with obesity especially those with family history of type 2 diabetes mellitus, polycystic ovary syndrome (PCO, gestational diabetes, cystic fibrosis, thalassemia major, acute coronary syndrome (ACS, and after renal transplantation. It appears that the ability of the CGMS for frequently monitoring (every 5 min glucose changes during real-life settings for 3 to 5 days stretches the chance to detect more glycemic abnormalities during basal and postprandial conditions compared to other short-timed methods.

  5. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    OpenAIRE

    Uemura, Mei

    2017-01-01

    Background: Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting h...

  6. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    OpenAIRE

    Mei Uemura; Yutaka Yano; Toshinari Suzuki; Taro Yasuma; Toshiyuki Sato; Aya Morimoto; Samiko Hosoya; Chihiro Suminaka; Hiromu Nakajima; Esteban C. Gabazza; Yoshiyuki Takei

    2017-01-01

    Background Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hy...

  7. Diabetes Technology-Continuous Subcutaneous Insulin Infusion Therapy and Continuous Glucose Monitoring in Adults: An Endocrine Society Clinical Practice Guideline.

    Science.gov (United States)

    Peters, Anne L; Ahmann, Andrew J; Battelino, Tadej; Evert, Alison; Hirsch, Irl B; Murad, M Hassan; Winter, William E; Wolpert, Howard

    2016-11-01

    To formulate clinical practice guidelines for the use of continuous glucose monitoring and continuous subcutaneous insulin infusion in adults with diabetes. The participants include an Endocrine Society-appointed Task Force of seven experts, a methodologist, and a medical writer. The American Association for Clinical Chemistry, the American Association of Diabetes Educators, and the European Society of Endocrinology co-sponsored this guideline. The Task Force developed this evidence-based guideline using the Grading of Recommendations, Assessment, Development, and Evaluation system to describe the strength of recommendations and the quality of evidence. The Task Force commissioned one systematic review and used the best available evidence from other published systematic reviews and individual studies. One group meeting, several conference calls, and e-mail communications enabled consensus. Committees and members of the Endocrine Society, the American Association for Clinical Chemistry, the American Association of Diabetes Educators, and the European Society of Endocrinology reviewed and commented on preliminary drafts of these guidelines. Continuous subcutaneous insulin infusion and continuous glucose monitoring have an important role in the treatment of diabetes. Data from randomized controlled trials are limited on the use of medical devices, but existing studies support the use of diabetes technology for a wide variety of indications. This guideline presents a review of the literature and practice recommendations for appropriate device use.

  8. A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

    Directory of Open Access Journals (Sweden)

    Mohammad Torkaman

    2016-03-01

    Full Text Available Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of hypoglycemia, admitted to Baqiyatallah Hospital of Tehran, Iran in 2012; the subjects were selected via simple sampling. After obtaining informed consents from the newborns’ parents, 1 cc blood samples were sent to the laboratory for measuring the blood glucose level. Moreover, venous blood samples, as well as heel-stick blood samples, were obtained for glucometer measurements. Blood glucose measurements were used to determine the cut-off value by the receiver operating characteristic (ROC curve and make comparisons with the diagnostic criteria for hypoglycemia in the literature. Results: A total of 238 infants with the mean weight of 2869±821.9 g were enrolled in this study. The mean (±SD blood glucose levels were 65.1±22.9, 82.9±24.7, and 84.4±24.8 mg/dl, based on the standard laboratory method, glucometer reading of venous blood samples, and glucometer reading of heel-stick capillary blood samples, respectively. The optimal cut-off point for hypoglycemia was determined as 65 mg/dl, using glucometer-based assessment of heel-stick blood samples. Conclusion: The significant difference in blood glucose levels measured by the laboratory method and outpatient glucometer readings highlights the importance of a cut-off value for rapid assessment and control of blood glucose and timely detection of hypoglycemia. In fact, the cut-off value introduced in the present study could facilitate such measurements.

  9. Automated integration of continuous glucose monitor data in the electronic health record using consumer technology.

    Science.gov (United States)

    Kumar, Rajiv B; Goren, Nira D; Stark, David E; Wall, Dennis P; Longhurst, Christopher A

    2016-05-01

    The diabetes healthcare provider plays a key role in interpreting blood glucose trends, but few institutions have successfully integrated patient home glucose data in the electronic health record (EHR). Published implementations to date have required custom interfaces, which limit wide-scale replication. We piloted automated integration of continuous glucose monitor data in the EHR using widely available consumer technology for 10 pediatric patients with insulin-dependent diabetes. Establishment of a passive data communication bridge via a patient's/parent's smartphone enabled automated integration and analytics of patient device data within the EHR between scheduled clinic visits. It is feasible to utilize available consumer technology to assess and triage home diabetes device data within the EHR, and to engage patients/parents and improve healthcare provider workflow. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  10. A label-free fiber-optic Turbidity Affinity Sensor (TAS) for continuous glucose monitoring.

    Science.gov (United States)

    Dutt-Ballerstadt, Ralph; Evans, Colton; Pillai, Arun P; Gowda, Ashok

    2014-11-15

    In this paper, we describe the concept of a novel implantable fiber-optic Turbidity Affinity Sensor (TAS) and report on the findings of its in-vitro performance for continuous glucose monitoring. The sensing mechanism of the TAS is based on glucose-specific changes in light scattering (turbidity) of a hydrogel suspension consisting of small particles made of crosslinked dextran (Sephadex G100), and a glucose- and mannose-specific binding protein - Concanavalin A (ConA). The binding of ConA to Sephadex particles results in a significant turbidity increase that is much greater than the turbidity contribution by the individual components. The turbidity of the TAS was measured by determining the intensity of light passing through the suspension enclosed within a small semi-permeable hollow fiber (OD: 220 μm, membrane thickness: 20 μm, molecular weight cut-off: 10 kDa) using fiber optics. The intensity of measured light of the TAS was proportional to the glucose concentration over the concentration range from 50mg/dL to 400mg/dL in PBS and whole blood at 37°C (R>0.96). The response time was approximately 4 min. The stability of the glucose response of the TAS decreased only slightly (by 20%) over an 8-day study period at 37°C. In conclusion, this study demonstrated proof-of-concept of the TAS for interstitial glucose monitoring. Due to the large signal amplitude of the turbidity change, and the lack of need for wavelength-specific emission and excitation filters, a very small, robust and compact TAS device with an extremely short optical pathlength could be feasibly designed and implemented for in-vivo glucose monitoring in people with diabetes. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Use of continuous glucose monitoring as an outcome measure in clinical trials.

    Science.gov (United States)

    Beck, Roy W; Calhoun, Peter; Kollman, Craig

    2012-10-01

    Although developed to be a management tool for individuals with diabetes, continuous glucose monitoring (CGM) also has potential value for the assessment of outcomes in clinical studies. We evaluated using CGM as such an outcome measure. Data were analyzed from six previously completed inpatient studies in which both CGM (Freestyle Navigator™ [Abbott Diabetes Care, Alameda, CA] or Guardian(®) [Medtronic, Northridge, CA]) and reference glucose measurements were available. The analyses included 97 days of data from 93 participants with type 1 diabetes (age range, 5-57 years; mean, 18 ± 12 years). Mean glucose levels per day were similar for the CGM and reference measurements (median, 148 mg/dL vs. 143 mg/dL, respectively; P = 0.92), and the correlation of the two was high (r = 0.89). Similarly, most glycemia metrics showed no significant differences comparing CGM and reference values, except that the nadir glucose tended to be slightly lower and peak glucose slightly higher with reference measurements than CGM measurements (respective median, 59 mg/dL vs. 66 mg/dL [P = 0.05] and 262 mg/dL vs. 257 mg/dL [P = 0.003]) and glucose variability as measured with the coefficient of variation was slightly lower with CGM than reference measurements (respective median, 31% vs. 35%; Pblood glucose measurements. CGM inaccuracy and underestimation of the extremes of hyperglycemia and hypoglycemia can be accounted for in a clinical trial's study design. Thus, in appropriate settings, CGM can be a very meaningful and feasible outcome measure for clinical trials.

  12. Accuracy of subcutaneous continuous glucose monitoring in critically ill adults: improved sensor performance with enhanced calibrations.

    Science.gov (United States)

    Leelarathna, Lalantha; English, Shane W; Thabit, Hood; Caldwell, Karen; Allen, Janet M; Kumareswaran, Kavita; Wilinska, Malgorzata E; Nodale, Marianna; Haidar, Ahmad; Evans, Mark L; Burnstein, Rowan; Hovorka, Roman

    2014-02-01

    Accurate real-time continuous glucose measurements may improve glucose control in the critical care unit. We evaluated the accuracy of the FreeStyle(®) Navigator(®) (Abbott Diabetes Care, Alameda, CA) subcutaneous continuous glucose monitoring (CGM) device in critically ill adults using two methods of calibration. In a randomized trial, paired CGM and reference glucose (hourly arterial blood glucose [ABG]) were collected over a 48-h period from 24 adults with critical illness (mean±SD age, 60±14 years; mean±SD body mass index, 29.6±9.3 kg/m(2); mean±SD Acute Physiology and Chronic Health Evaluation score, 12±4 [range, 6-19]) and hyperglycemia. In 12 subjects, the CGM device was calibrated at variable intervals of 1-6 h using ABG. In the other 12 subjects, the sensor was calibrated according to the manufacturer's instructions (1, 2, 10, and 24 h) using arterial blood and the built-in point-of-care glucometer. In total, 1,060 CGM-ABG pairs were analyzed over the glucose range from 4.3 to 18.8 mmol/L. Using enhanced calibration median (interquartile range) every 169 (122-213) min, the absolute relative deviation was lower (7.0% [3.5, 13.0] vs. 12.8% [6.3, 21.8], P<0.001), and the percentage of points in the Clarke error grid Zone A was higher (87.8% vs. 70.2%). Accuracy of the Navigator CGM device during critical illness was comparable to that observed in non-critical care settings. Further significant improvements in accuracy may be obtained by frequent calibrations with ABG measurements.

  13. The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy

    DEFF Research Database (Denmark)

    Battelino, T; Conget, I; Olsen, B

    2012-01-01

    The aim of this multicentre, randomised, controlled crossover study was to determine the efficacy of adding continuous glucose monitoring (CGM) to insulin pump therapy (CSII) in type 1 diabetes.......The aim of this multicentre, randomised, controlled crossover study was to determine the efficacy of adding continuous glucose monitoring (CGM) to insulin pump therapy (CSII) in type 1 diabetes....

  14. Hydrothermal gasification of glucose and starch in a batch and continuous reactor

    Directory of Open Access Journals (Sweden)

    Kazuhiro Kumabe

    2017-11-01

    Full Text Available A batch reactor was used for the gasification of glucose and starch as carbohydrate model compounds. The effects of H2O in various states (low-pressure hot compressed water (LP-HCW, 300 °C and 10 MPa, high-pressure hot compressed water (HP-HCW, 360 °C and 20 MPa, high-temperature steam (HTS, 400 °C and 10 MPa, and supercritical water (SCW, 400 °C and 25 MPa, as well as reaction time (10, 30, and 60 min, sample concentration (10, 20, and 30 wt%, and catalyst (mixture of Ca(OH2 and Na2CO3 on gas production were investigated in the hydrothermal gasification. In addition, using a continuous reactor, the hydrothermal gasification of glucose was examined with LP-HCW (200 °C and 5 MPa, HP-HCW (200 °C and 25 MPa, HTS (600 °C, 5 MPa, and SCW (600 °C, 25 MPa in order to study the productions of gases and tar, and the mass balance. The reaction temperature affected gasification considerably, but pressure had little effect. In the batch experiments, the characteristics of the produced gases were almost identical after a reaction time of 10 min, and addition of Ca(OH2 and Na2CO3 as catalysts in a molar ratio of 7:3 led to selective production of H2 in the SCW gasification of 10 wt% glucose for 30 min. In a continuous experiment under the SCW conditions, the conversion efficiency of glucose to gas was 26% and the composition of the produced gas was 29 vol% CO, 23 vol% H2, and 16 vol% CH4. Under the hydrothermal conditions, glucose was mainly converted to char and suspended components of high-molecular-weight compounds such as fat, whereas starch was mainly converted to gas and liquid.

  15. The effectiveness of continuous subcutaneous insulin pumps with continuous glucose monitoring in outpatient adolescents with type 1 diabetes: A systematic review.

    Science.gov (United States)

    Matsuda, Erin; Brennan, Patricia

    2012-01-01

    risk of comorbidity . Data from this significant study continues to contribute to current diabetes management. According to the ADA, children and adolescents should monitor their blood glucose at least three or more times per day. Blood glucose data is utilised to calculate appropriate insulin doses. Similar to the CGM, information from the glucometers can be downloaded for assessment of results and trends. However, the result is dependent on the action of the patient to obtain the sample and only represents a specific moment in time whereas the CGM sensor continuously tracks the blood glucose level. Depending on the model, CGM can provide glucose levels every one to ten minutes. The sensor may last for up to 72 hours and results are available in real time .This systematic review will address two metabolic outcomes: a decrease in the number of hypoglycemic episodes and a haemoglobin A1C level <7.5%. These outcomes were chosen due to their significance as indicators in the management of type 1 diabetes. Glucose levels should be between 90 mg/dL and 130 mg/dL (5.0mmol/l and 7.2mmol/l) before meals and between 90 mg/dL and 150 mg/dL at night (5.0mmmol/l and 8.3mmol/l) . Optimal care of an adolescent with type 1 diabetes mellitus is to safely maintain glycemic control and avoid hypoglycemia.Haemoglobin A1C is an indicator of how well the disease is being managed and should be evaluated every three months. McCulloch recommends the haemoglobin A1C level should be compared to approximately 50 recent blood glucose readings to ensure the accuracy of patient SGM . The reliability and validity of this test is based on the evidence discovered by the DCCT demonstrating those with lower haemoglobin A1C levels have fewer complications . The target A1C for adolescents, aged 13 to 19 years of age, is <7.5% . This is consistent with the National Institute of Clinical Excellence (NICE) and diabetes management guidelines of the Australasian Paediatric Endocrine Group for the Department of

  16. Model Identification using Continuous Glucose Monitoring Data for Type 1 Diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Hagdrup, Morten; Mahmoudi, Zeinab

    2016-01-01

    This paper addresses model identification of continuous-discrete nonlinear models for people with type 1 diabetes using sampled data from a continuous glucose monitor (CGM). We compare five identification techniques: least squares, weighted least squares, Huber regression, maximum likelihood...... with extended Kalman filter and maximum likelihood with unscented Kalman filter. We perform the identification on a 24-hour simulation of a stochastic differential equation (SDE) version of the Medtronic Virtual Patient (MVP) model including process and output noise. We compare the fits with the actual CGM......, such as parameter tracking, population modeling and handling of outliers....

  17. Continuous glucose monitoring--a study of the Enlite sensor during hypo- and hyperbaric conditions.

    Science.gov (United States)

    Adolfsson, Peter; Örnhagen, Hans; Eriksson, Bengt M; Cooper, Ken; Jendle, Johan

    2012-06-01

    The performance and accuracy of the Enlite(™) (Medtronic, Inc., Northridge, CA) sensor may be affected by microbubble formation at the electrode surface during hypo- and hyperbaric conditions. The effects of acute pressure changes and of prewetting of sensors were investigated. On Day 1, 24 sensors were inserted on the right side of the abdomen and back in one healthy individual; 12 were prewetted with saline solution, and 12 were inserted dry. On Day 2, this procedure was repeated on the left side. All sensors were attached to an iPro continuous glucose monitoring (CGM) recorder. Hypobaric and hyperbaric tests were conducted in a pressure chamber, with each test lasting 105 min. Plasma glucose values were obtained at 5-min intervals with a HemoCue(®) (Ängelholm, Sweden) model 201 glucose analyzer for comparison with sensor glucose values. Ninety percent of the CGM systems operated during the tests. The mean absolute relative difference was lower during hyperbaric than hypobaric conditions (6.7% vs. 14.9%, Phypobaric but not during hyperbaric conditions. Clarke Error Grid Analysis showed that 100% of the values were found in the A+B region. No differences were found between prewetted and dry sensors. The Enlite sensor performed adequately during acute pressure changes and was more accurate during hyperbaric than hypobaric conditions. Prewetting the sensors did not improve accuracy. Further studies on type 1 diabetes subjects are needed under various pressure conditions.

  18. Practical implementation, education and interpretation guidelines for continuous glucose monitoring: A French position statement.

    Science.gov (United States)

    Borot, S; Benhamou, P Y; Atlan, C; Bismuth, E; Bonnemaison, E; Catargi, B; Charpentier, G; Farret, A; Filhol, N; Franc, S; Gouet, D; Guerci, B; Guilhem, I; Guillot, C; Jeandidier, N; Joubert, M; Melki, V; Merlen, E; Penfornis, A; Picard, S; Renard, E; Reznik, Y; Riveline, J P; Rudoni, S; Schaepelynck, P; Sola-Gazagnes, A; Tubiana-Rufi, N; Verier-Mine, O; Hanaire, H

    2018-02-01

    The use by diabetes patients of real-time continuous interstitial glucose monitoring (CGM) or the FreeStyle Libre ® (FSL) flash glucose monitoring (FGM) system is becoming widespread and has changed diabetic practice. The working group bringing together a number of French experts has proposed the present practical consensus. Training of professionals and patient education are crucial for the success of CGM. Also, institutional recommendations must pay particular attention to the indications for and reimbursement of CGM devices in populations at risk of hypoglycaemia. The rules of good practice for CGM are the precursors of those that need to be enacted, given the oncoming emergence of artificial pancreas devices. It is necessary to have software combining user-friendliness, multiplatform usage and average glucose profile (AGP) presentation, while integrating glucose and insulin data as well as events. Expression of CGM data must strive for standardization that facilitates patient phenotyping and their follow-up, while integrating indicators of variability. The introduction of CGM involves a transformation of treatment support, rendering it longer and more complex as it also includes specific educational and technical dimensions. This complexity must be taken into account in discussions of organization of diabetes care. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Unannounced Meals in the Artificial Pancreas: Detection Using Continuous Glucose Monitoring

    Directory of Open Access Journals (Sweden)

    Charrise M. Ramkissoon

    2018-03-01

    Full Text Available The artificial pancreas (AP system is designed to regulate blood glucose in subjects with type 1 diabetes using a continuous glucose monitor informed controller that adjusts insulin infusion via an insulin pump. However, current AP developments are mainly hybrid closed-loop systems that include feed-forward actions triggered by the announcement of meals or exercise. The first step to fully closing the loop in the AP requires removing meal announcement, which is currently the most effective way to alleviate postprandial hyperglycemia due to the delay in insulin action. Here, a novel approach to meal detection in the AP is presented using a sliding window and computing the normalized cross-covariance between measured glucose and the forward difference of a disturbance term, estimated from an augmented minimal model using an Unscented Kalman Filter. Three different tunings were applied to the same meal detection algorithm: (1 a high sensitivity tuning, (2 a trade-off tuning that has a high amount of meals detected and a low amount of false positives (FP, and (3 a low FP tuning. For the three tunings sensitivities 99 ± 2%, 93 ± 5%, and 47 ± 12% were achieved, respectively. A sensitivity analysis was also performed and found that higher carbohydrate quantities and faster rates of glucose appearance result in favorable meal detection outcomes.

  20. Correlation of continuous glucose monitoring profiles with pregnancy outcomes in nondiabetic women.

    Science.gov (United States)

    Sung, Joyce F; Kogut, Elizabeth A; Lee, Henry C; Mannan, Jana L; Navabi, Kasra; Taslimi, M Mark; El-Sayed, Yasser Y

    2015-04-01

    To determine whether hyperglycemic excursions detected by continuous glucose monitoring (CGM) correlate with birth weight percentile and other pregnancy outcomes, and whether CGM correlates better with these outcomes than a single glucose value from a 1-hour glucose challenge test (GCT). This was a prospective observational study of 55 pregnant patients without preexisting diabetes, who wore a CGM device for up to 7 days, between 24 and 28 weeks' gestation. The area under the curve (AUC) of hyperglycemic excursions above various thresholds (110, 120, 130, 140, and 180 mg/dL) was calculated. These AUC values, and results from a standard 50-g GCT, were correlated with our primary outcome of birth weight percentile, and secondary outcomes of unplanned operative delivery, pregnancy complications, delivery complications, fetal complications, and neonatal complications. A consistent correlation was seen between all AUC thresholds and birth weight percentile (r = 0.29, p AUC-110, -120, -130, and -140; r = 0.25, p = 0.07 for AUC-180). This correlation was stronger than that of 1-hour oral GCT (r = -0.02, p = 0.88). There was no association between AUC values and other outcomes. Among nondiabetic pregnant patients, hyperglycemic excursions detected by CGM show a stronger correlation to birth weight percentile than blood glucose values obtained 1-hour after a 50-g oral GCT. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. Fault and meal detection by redundant continuous glucose monitors and the unscented Kalman filter

    DEFF Research Database (Denmark)

    Mahmoudi, Zeinab; Nørgaard, Kirsten; Poulsen, Niels Kjølstad

    2017-01-01

    The purpose of this study is to develop a method for detecting and compensating the anomalies of continuous glucose monitoring (CGM) sensors as well as detecting unannounced meals. Both features, sensor fault detection/correction and meal detection, are necessary to have a reliable artificial pan...... is corrupted by PISA. The fault isolator can detect 199 out of 200 unannounced meals. The average change in the glucose concentrations between the meals and the detection time points is 46.3 mg/dL.......The purpose of this study is to develop a method for detecting and compensating the anomalies of continuous glucose monitoring (CGM) sensors as well as detecting unannounced meals. Both features, sensor fault detection/correction and meal detection, are necessary to have a reliable artificial...... from the two fault detectors differentiates between a sensor fault and an unannounced meal appearing as an anomaly in the CGM data. If the fault isolator indicates a sensor fault, a method based on the covariance matching technique tunes the covariance of the measurement noise associated...

  2. Comparison of accuracy and safety of the SEVEN and the Navigator continuous glucose monitoring systems.

    Science.gov (United States)

    Garg, Satish K; Smith, James; Beatson, Christie; Lopez-Baca, Benita; Voelmle, Mary; Gottlieb, Peter A

    2009-02-01

    This study evaluated the accuracy and safety of two continuous glucose monitoring (CGM) systems, the SEVEN (DexCom, San Diego, CA) and the Navigator (Abbott Diabetes Care, Alameda, CA), with the YSI laboratory measurements of blood glucose (blood glucose meter manufactured by YSI, Yellow Springs, OH), when worn concurrently in adults with type 1 diabetes. Fourteen subjects with type 1 diabetes, 33 +/- 6 (mean +/- SD) years old, were enrolled in this study. All subjects wore both sensors concurrently over three consecutive 5-day CGM sessions (15-day wear). On Days 5, 10, and 15, subjects participated in an 8-h in-clinic session where measurements from the CGM systems were collected and compared with YSI measurements every 15 min. At the end of Day 5 and 10 in-clinic sessions, the sensors were removed, and new sensors were inserted for the following CGM session despite the SEVEN system's recommended use for up to 7 days. The mean absolute relative difference (ARD) for the two CGM devices versus YSI was not different: 16.8% and 16.1% for SEVEN and Navigator, respectively (P = 0.38). In the hypoglycemic region (YSI value blood glucose (SMBG) values. Thirteen additional Navigator replacement devices were issued compared to two for the SEVEN. A total of three versus 14 skin reactions were reported with the SEVEN and Navigator insertion area, respectively. Glucose measurements with the SEVEN and Navigator were found to be similar compared with YSI and SMBG measurements, with the exception of the hypoglycemic range where the SEVEN performed better. However, the Navigator caused more skin area reactions.

  3. Continuous glucose monitoring microsensor with a nanoscale conducting matrix and redox mediator

    Science.gov (United States)

    Pesantez, Daniel

    The major limiting factor in kidney clinical transplantation is the shortage of transplantable organs. The current inability to distinguish viability from non-viability on a prospective basis represents a major obstacle in any attempt to expand organ donor criteria. Consequently, a way to measure and monitor a relevant analyte to assess kidney viability is needed. For the first time, the initial development and characterization of a metabolic microsensor to assess kidney viability is presented. The rate of glucose consumption appears to serve as an indicator of kidney metabolism that may distinguish reversible from irreversible kidney damage. The proposed MetaSense (Metabolic Sensor) microdevice would replace periodic laboratory diagnosis tests with a continuous monitor that provides real-time data on organ viability. Amperometry, a technique that correlates an electrical signal with analyte concentration, is used as a method to detect glucose concentrations. A novel two-electrode electrochemical sensing cell design is presented. It uses a modified metallic working electrode (WE) and a bare metallic reference electrode (RE) that acts as a pseudo-reference/counter electrode as well. The proposed microsensor has the potential to be used as a minimally invasive sensor for its reduced number of probes and very small dimensions achieved by micromachining and lithography. In order to improve selectivity of the microdevice, two electron transfer mechanisms or generations were explored. A first generation microsensor uses molecular oxygen as the electron acceptor in the enzymatic reaction and oxidizes hydrogen peroxide (H2O2) to get the electrical signal. The microsensor's modified WE with conductive polymer polypyrrole (PPy) and corresponding enzyme glucose oxidase (GOx) immobilized into its matrix, constitutes the electrochemical detection mechanism. Photoluminescence spectroscopic analysis confirmed and quantified enzyme immobilized concentrations within the matrix. In

  4. HBA1C AND MEAN GLUCOSE DERIVED FROM SHORT-TERM CONTINUOUS GLUCOSE MONITORING ASSESSMENT DO NOT CORRELATE IN PATIENTS WITH HBA1C >8.

    Science.gov (United States)

    Yamada, Eijiro; Okada, Shuichi; Nakajima, Yasuyo; Bastie, Claire C; Vatish, Manu; Tagaya, Yuko; Osaki, Aya; Shimoda, Yoko; Shibusawa, Ryo; Saito, Tsugumichi; Okamura, Takashi; Ozawa, Atsushi; Yamada, Masanobu

    2017-01-01

    Optimum therapy for patients with diabetes depends on both acute and long-term changes in plasma glucose, generally assessed by glycated hemoglobin (HbA1c) levels. However, the correlation between HbA1c and circulating glucose has not been fully determined. Therefore, we carefully examined this correlation when glucose levels were assessed by continuous glucose monitoring (CGM). Fifty-one patients (70% female, 30% male) were examined; among them were 28 with type 1 diabetes and 23 with type 2 diabetes. Clinically determined HbA1c levels were compared with blood glucose determined by CGM during a short time period. Changes in HbA1c levels up to 8.0% showed a clear and statistically strong correlation (R = 0.6713; PHbA1c and CGM-assessed glucose levels in our patient population when HbA1c was >8.0%. Short-term CGM appears to be a good clinical indicator of long-term glucose control (HbA1c levels); however, cautions should be taken while interpreting CGM data from patients with HbA1c levels >8.0%. Over- or underestimation of the actual mean glucose from CGM data could potentially increase the risks of inappropriate treatment. As such, our results indicate that a more accurate analysis of CGM data might be useful to adequately tailor clinical treatments. ADAG = A1c-Derived Average Glucose CGM = continuous glucose monitoring %CV = percent coefficient of variation HbA1c = glycated hemoglobin.

  5. Effect of Continuous Glucose Monitoring Accuracy on Clinicians' Retrospective Decision Making in Diabetes: A Pilot Study

    DEFF Research Database (Denmark)

    Mahmoudi, Zeinab; Johansen, Mette Dencker; Nørgaard, Hanne Holdflod

    2015-01-01

    BACKGROUND: The use of continuous glucose monitoring (CGM) in clinical decision making in diabetes could be limited by the inaccuracy of CGM data when compared to plasma glucose measurements. The aim of the present study is to investigate the impact of CGM numerical accuracy on the precision...... of diabetes treatment adjustments. METHOD: CGM profiles with maximum 5-day duration from 12 patients with type 1 diabetes treated with a basal-bolus insulin regimen were processed by 2 CGM algorithms, with the accuracy of algorithm 2 being higher than the accuracy of algorithm 1, using the median absolute...... of the interclinician agreement and the intraclinician reproducibility of the decisions. The Cohen's kappa coefficient was used to assess the precision of the decisions. The study was based on retrospective and blind CGM data. RESULTS: For the interclinician agreement, in the first occasion, the kappa of algorithm 1...

  6. Comparison of three nonlinear filters for fault detection in continuous glucose monitors.

    Science.gov (United States)

    Mahmoudi, Zeinab; Wendt, Sabrina Lyngbye; Boiroux, Dimitri; Hagdrup, Morten; Norgaard, Kirsten; Poulsen, Niels Kjolstad; Madsen, Henrik; Jorgensen, John Bagterp

    2016-08-01

    The purpose of this study is to compare the performance of three nonlinear filters in online drift detection of continuous glucose monitors. The nonlinear filters are the extended Kalman filter (EKF), the unscented Kalman filter (UKF), and the particle filter (PF). They are all based on a nonlinear model of the glucose-insulin dynamics in people with type 1 diabetes. Drift is modelled by a Gaussian random walk and is detected based on the statistical tests of the 90-min prediction residuals of the filters. The unscented Kalman filter had the highest average F score of 85.9%, and the smallest average detection delay of 84.1%, with the average detection sensitivity of 82.6%, and average specificity of 91.0%.

  7. Accuracy evaluation of a new real-time continuous glucose monitoring algorithm in hypoglycemia

    DEFF Research Database (Denmark)

    Mahmoudi, Zeinab; Jensen, Morten Hasselstrøm; Johansen, Mette Dencker

    2014-01-01

    UNLABELLED: Abstract Background: The purpose of this study was to evaluate the performance of a new continuous glucose monitoring (CGM) calibration algorithm and to compare it with the Guardian(®) REAL-Time (RT) (Medtronic Diabetes, Northridge, CA) calibration algorithm in hypoglycemia. SUBJECTS...... AND METHODS: CGM data were obtained from 10 type 1 diabetes patients undergoing insulin-induced hypoglycemia. Data were obtained in two separate sessions using the Guardian RT CGM device. Data from the same CGM sensor were calibrated by two different algorithms: the Guardian RT algorithm and a new calibration...... algorithm. The accuracy of the two algorithms was compared using four performance metrics. RESULTS: The median (mean) of absolute relative deviation in the whole range of plasma glucose was 20.2% (32.1%) for the Guardian RT calibration and 17.4% (25.9%) for the new calibration algorithm. The mean (SD...

  8. Continuous glucose monitoring for patients with diabetes: an evidence-based analysis.

    Science.gov (United States)

    2011-01-01

    To determine the effectiveness and cost-effectiveness of continuous glucose monitoring combined with self-monitoring of blood glucose compared with self-monitoring of blood glucose alone in the management of diabetes. CONDITION AND TARGET POPULATION Diabetes is a chronic metabolic disorder that interferes with the body's ability to produce or effectively use insulin. In 2005, an estimated 816,000 Ontarians had diabetes representing 8.8% of the province's population. Type 1 or juvenile onset diabetes is a life-long disorder that commonly manifests in children and adolescents. It represents about 10% of the total diabetes population and involves immune-mediated destruction of insulin producing cells in the pancreas. The loss of these cells necessitates insulin therapy. Type 2 or "adult-onset" diabetes represents about 90% of the total diabetes population and is marked by a resistance to insulin or insufficient insulin secretion. The risk of developing type 2 diabetes increases with age, obesity and lack of physical activity. Approximately 30% of patients with type 2 diabetes eventually require insulin therapy. Continuous glucose monitors (CGM) measure glucose levels in the interstitial fluid surrounding skin cells. These measurements supplement conventional self monitoring of blood glucose (SMBG) by monitoring the glucose fluctuations continuously over a stipulated period of time, thereby identifying fluctuations that would not be identified with SMBG alone. To use a CGM, a sensor is inserted under the skin to measure glucose in the interstitial fluid. The sensor is wired to a transmitter. The device requires calibration using a capillary blood glucose measurement. Each sensor continuously measures glucose every 5-10 seconds averaging these values every 5 minutes and storing this data in the monitors memory. Depending on the device used, the algorithm in the device can measure glucose over a 3 or 6 day period using one sensor. After the 3 or 6 day period, a new

  9. Continuous glucose monitoring and its relationship to hemoglobin A1c and oral glucose tolerance testing in obese and prediabetic youth.

    Science.gov (United States)

    Chan, Christine L; Pyle, Laura; Newnes, Lindsey; Nadeau, Kristen J; Zeitler, Philip S; Kelsey, Megan M

    2015-03-01

    The optimal screening test for diabetes and prediabetes in obese youth is controversial. We examined whether glycosylated hemoglobin (HbA1c) or the oral glucose tolerance test (OGTT) is a better predictor of free-living glycemia as measured by continuous glucose monitoring (CGM). This was a cross-sectional study of youth 10-18 years old, body mass index (BMI) 85th percentile or greater, with diabetes risk factors. Participants (n = 118) with BMI 85th percentile or greater, not on medications for glucose management, were recruited from primary care and pediatric endocrinology clinics around Denver, Colorado. HbA1c, fasting plasma glucose, and 2-hour glucose were collected and all participants wore a blinded CGM for 72 hours. CGM outcomes were determined and descriptive statistics calculated. Performance characteristics at current American Diabetes Association cutpoints were compared with CGM outcomes. CGM data were successfully collected on 98 obese youth. Those with prediabetes had significantly higher average glucose, area under the curve (AUC), peak glucose, and time greater than 120 and greater than 140 mg/dL (P obese youth, HbA1c and 2-hour glucose performed equally well at predicting free-living glycemia on CGM, suggesting that both are valid tests for dysglycemia screening.

  10. Translating glucose variability metrics into the clinic via Continuous Glucose Monitoring: a Graphical User Interface for Diabetes Evaluation (CGM-GUIDE©).

    Science.gov (United States)

    Rawlings, Renata A; Shi, Hang; Yuan, Lo-Hua; Brehm, William; Pop-Busui, Rodica; Nelson, Patrick W

    2011-12-01

    Several metrics of glucose variability have been proposed to date, but an integrated approach that provides a complete and consistent assessment of glycemic variation is missing. As a consequence, and because of the tedious coding necessary during quantification, most investigators and clinicians have not yet adopted the use of multiple glucose variability metrics to evaluate glycemic variation. We compiled the most extensively used statistical techniques and glucose variability metrics, with adjustable hyper- and hypoglycemic limits and metric parameters, to create a user-friendly Continuous Glucose Monitoring Graphical User Interface for Diabetes Evaluation (CGM-GUIDE©). In addition, we introduce and demonstrate a novel transition density profile that emphasizes the dynamics of transitions between defined glucose states. Our combined dashboard of numerical statistics and graphical plots support the task of providing an integrated approach to describing glycemic variability. We integrated existing metrics, such as SD, area under the curve, and mean amplitude of glycemic excursion, with novel metrics such as the slopes across critical transitions and the transition density profile to assess the severity and frequency of glucose transitions per day as they move between critical glycemic zones. By presenting the above-mentioned metrics and graphics in a concise aggregate format, CGM-GUIDE provides an easy to use tool to compare quantitative measures of glucose variability. This tool can be used by researchers and clinicians to develop new algorithms of insulin delivery for patients with diabetes and to better explore the link between glucose variability and chronic diabetes complications.

  11. Importance of manually entering blood glucose readings when wireless-compatible meters are not being used with an insulin pump.

    Science.gov (United States)

    Driscoll, Kimberly A; Johnson, Suzanne Bennett; Wang, Yuxia; Tang, Yuanyuan; Gill, Elizabeth C; Mitchell, Adela; Wright, Nancy; Deeb, Larry C

    2013-07-01

    The objective was to determine if there were differences in blood glucose monitoring (BGM) data downloaded from insulin pumps of patients who use meters that wirelessly transmit data to their insulin pumps (i.e., wireless group) and those who do not (i.e., nonwireless group). Blood glucose monitoring data were downloaded from the meters and insulin pumps of 47 children and adolescents with type 1 diabetes mellitus. Independent and paired t tests compared BGM data downloaded from meters and BGM data downloaded from insulin pumps. There were significant differences in BGM data downloaded from the insulin pumps of patients using wireless meters compared to those using nonwireless meters. Wireless patients appeared to engage in more BGM, had more low and in-range BG readings and fewer very high BG readingss than nonwireless patients. However, a comparison of BGM data downloaded from meters and insulin pumps of nonwireless patients indicated that their insulin pump data significantly underestimated the number of BGM readings conducted, as well as the number of low and in-range readings, while overestimating the number of very high BGM readings. Because patients who use nonwireless-compatible meters do not manually enter their low and in-range BGM readings into the insulin pump, BGM data downloaded only from pumps may provide an incomplete representation of BGM frequency or results. It is recommended that patients use meters that directly communicate with pumps or perform bolus calculations. Patients should be educated about the importance of manually entering all BGM readings if they do not use a wireless-compatible meter with their insulin pump. © 2013 Diabetes Technology Society.

  12. Performance evaluations of continuous glucose monitoring systems: precision absolute relative deviation is part of the assessment.

    Science.gov (United States)

    Obermaier, Karin; Schmelzeisen-Redeker, Günther; Schoemaker, Michael; Klötzer, Hans-Martin; Kirchsteiger, Harald; Eikmeier, Heino; del Re, Luigi

    2013-07-01

    Even though a Clinical and Laboratory Standards Institute proposal exists on the design of studies and performance criteria for continuous glucose monitoring (CGM) systems, it has not yet led to a consistent evaluation of different systems, as no consensus has been reached on the reference method to evaluate them or on acceptance levels. As a consequence, performance assessment of CGM systems tends to be inconclusive, and a comparison of the outcome of different studies is difficult. Published information and available data (as presented in this issue of Journal of Diabetes Science and Technology by Freckmann and coauthors) are used to assess the suitability of several frequently used methods [International Organization for Standardization, continuous glucose error grid analysis, mean absolute relative deviation (MARD), precision absolute relative deviation (PARD)] when assessing performance of CGM systems in terms of accuracy and precision. The combined use of MARD and PARD seems to allow for better characterization of sensor performance. The use of different quantities for calibration and evaluation, e.g., capillary blood using a blood glucose (BG) meter versus venous blood using a laboratory measurement, introduces an additional error source. Using BG values measured in more or less large intervals as the only reference leads to a significant loss of information in comparison with the continuous sensor signal and possibly to an erroneous estimation of sensor performance during swings. Both can be improved using data from two identical CGM sensors worn by the same patient in parallel. Evaluation of CGM performance studies should follow an identical study design, including sufficient swings in glycemia. At least a part of the study participants should wear two identical CGM sensors in parallel. All data available should be used for evaluation, both by MARD and PARD, a good PARD value being a precondition to trust a good MARD value. Results should be analyzed and

  13. Privacy and Security Issues Surrounding the Protection of Data Generated by Continuous Glucose Monitors.

    Science.gov (United States)

    Britton, Katherine E; Britton-Colonnese, Jennifer D

    2017-03-01

    Being able to track, analyze, and use data from continuous glucose monitors (CGMs) and through platforms and apps that communicate with CGMs helps achieve better outcomes and can advance the understanding of diabetes. The risks to patients' expectation of privacy are great, and their ability to control how their information is collected, stored, and used is virtually nonexistent. Patients' physical security is also at risk if adequate cybersecurity measures are not taken. Currently, data privacy and security protections are not robust enough to address the privacy and security risks and stymies the current and future benefits of CGM and the platforms and apps that communicate with them.

  14. A history of continuous glucose monitors (CGMs) in self-monitoring of diabetes mellitus.

    Science.gov (United States)

    Olczuk, David; Priefer, Ronny

    Self-monitoring of glucose for individuals afflicted with diabetes mellitus has allowed patients to take control of their disease and thus directly affect the outcomes related to it. It has been almost a century since the first test to monitor one's sugar was developed; that being a urine test. The most well-known and prominent medical device for monitor blood glucose for individuals with diabetes are the finger-prick devices. This itself is an approximately 50year old technology. More recently has been the introduction of continuous glucose monitors (CGMs) which entered the market place in the last year of the 20th century. As this technology has been further refined and improved, limitations associated with it have decreased. The scope of this review is to present a brief history of CGMs, both with the development of these medical devices and the challenges/limitations that they have shown. Copyright © 2017 Diabetes India. Published by Elsevier Ltd. All rights reserved.

  15. A comparative effectiveness analysis of three continuous glucose monitors: the Navigator, G4 Platinum, and Enlite.

    Science.gov (United States)

    Damiano, Edward R; McKeon, Katherine; El-Khatib, Firas H; Zheng, Hui; Nathan, David M; Russell, Steven J

    2014-07-01

    The effectiveness and safety of continuous glucose monitors (CGMs) is dependent on their accuracy and reliability. The objective of this study was to compare 3 CGMs in adult and pediatric subjects with type 1 diabetes under closed-loop blood-glucose (BG) control. Twenty-four subjects (12 adults) with type 1 diabetes each participated in one 48-hour closed-loop BG control experiment. Venous plasma glucose (PG) measurements obtained every 15 minutes (4657 values) were paired in time with corresponding CGM glucose (CGMG) measurements obtained from 3 CGMs (FreeStyle Navigator, Abbott Diabetes Care; G4 Platinum, Dexcom; Enlite, Medtronic) worn simultaneously by each subject. The Navigator and G4 Platinum (G4) had the best overall accuracy, with an aggregate mean absolute relative difference (MARD) of all paired points of 12.3 ± 12.1% and 10.8 ± 9.9%, respectively. Both had lower MARDs of all paired points than Enlite (17.9 ± 15.8%, P 50%) were less common with the G4 (0.5%) than with the Enlite (4.3%, P = .0001) while the number of very large errors with the Navigator (1.4%) was intermediate between the G4 and Enlite (P = .1 and P = .06, respectively). The average MARD for experiments in adolescent subjects were lower than in adult subjects for the Navigator and G4, while there was no difference for Enlite. All 3 devices had similar reliability. A comprehensive head-to-head-to-head comparison of 3 CGMs revealed marked differences in both accuracy and precision. The Navigator and G4 were found to outperform the Enlite in these areas. © 2014 Diabetes Technology Society.

  16. COMPARISON OF THE RESULTS OF BLOOD GLUCOSE SELFMONITORING AND CONTINUOUS GLUCOSE MONITORING IN PREGNANT WOMEN WITH PREVIOUS DIABETES MELLITUS

    Directory of Open Access Journals (Sweden)

    A. V. Dreval'

    2015-01-01

    Full Text Available Background: Pregnancy is one of the indications for continuous glucose monitoring (CGM. The data on its efficiency in pregnant women are contradictory.Aim: To compare the results of blood glucose self-monitoring (SMBG and CGM in pregnant women with previous diabetes mellitus.Materials and methods: We performed a cross-sectional comparative study of glycemia in 18 pregnant women with previous type 1 (87.8% of patients and type 2 diabetes (22.2% of patients with various degrees of glycemic control. Their age was 27.7 ± 4.9 year. At study entry, the patients were at 17.2 ± 6.1 weeks of gestation. CGM and SMBG were performed in and by all patients for the duration of 5.4 ± 1.5 days. Depending on their HbA1c levels, all patients were divided into two groups: group 1 – 12 women with the HbA1c above the target (8.5 ± 1%, and group 2 – 6 women with the HbA1c levels within the target (5.6 ± 0.3%.Results: According to SMBG results, women from group 2 had above-the-target glycemia levels before breakfast, at 1 hour after breakfast and at bedtime: 6.2 ± 1.6, 8.7 ± 2.1, and 5.7 ± 1.9 mmol/L, respectively. According to CGM, patients from group 1 had higher postprandial glycemia than those from group 2 (8.0 ± 2.1 and 6.9 ± 1.8 mmol/L, respectively, p = 0.03. The analysis of glycemia during the day time revealed significant difference between the groups only at 1 hour after dinner (7.1 ± 1.4 mmol/L in group 1 and 5.8 ± 0.9 mmol/L in group 2, р = 0.041 and the difference was close to significant before lunch (6.0 ± 2.2 mmol/L in group 1 and 4.8 ± 1.0 mmol/L in group 2, р = 0.053. Comparison of SMBG and CGM results demonstrated significant difference only at one timepoint (at 1 hour after lunch and only in group 1: median glycemia was 7.4 [6.9; 8.1] mmol/L by SMBG and 6 [5.4; 6.6] mmol/L by CGM measurement (р = 0.001. Lower median values by CGM measurement could be explained by averaging of three successive measurements carried out in the

  17. Effects of Everyday Life Events on Glucose, Insulin, and Glucagon Dynamics in Continuous Subcutaneous Insulin Infusion–Treated Type 1 Diabetes: Collection of Clinical Data for Glucose Modeling

    DEFF Research Database (Denmark)

    Schmidt, Signe; Finan, Daniel Aaron; Duun-Henriksen, Anne Katrine

    2012-01-01

    metabolism, we designed and conducted a clinical study.Methods: Patients with insulin pump–treated T1D were recruited to perform everyday life events on two separate days. During the study, patients wore their insulin pumps and, in addition, a continuous glucose monitor and an activity monitor to estimate...

  18. [Current status of continuous subcutaneous insulin infusion and continuous glucose monitoring systems in the Community of Madrid].

    Science.gov (United States)

    Arranz Martín, Alfonso; Calle Pascual, Alfonso; Del Cañizo Gómez, Francisco Javier; González Albarrán, Olga; Lisbona Gil, Arturo; Botella Serrano, Marta; Pallardo Sánchez, Luis Felipe

    2015-04-01

    To analyze the available information about continuous subcutaneous insulin infusion (CSII) and continuous glucose monitoring (CGM) systems in the public health care system of the Community of Madrid. A survey consisting of 31 items was sent to the 28 endocrinology department of the Madrid public hospitals. Items focused on CSII and CGM and included patients' registrations, as well as data regarding healthcare, administrative, and logistic aspects. Responses from a total of 20 hospitals where these procedures are used were received from March 2013 to May 2014. Data about pediatric patients were obtained from adult endocrinology departments, except for two hospitals which directly reported the information. A total of 1256 CSII pumps were recorded in the Madrid region, of which 1089 were used by adults, and the remaining 167 by pediatric patients. During 2013, 151 new CSII systems were implanted (12% of the total), while 14 pumps were withdrawn. Availability of human resources (medical assistance) and the number of staff practitioners experienced in management of these systems widely varied between hospitals. Eighty-five percent of hospitals used retrospective CGM systems, and 40% routinely placed them before starting an insulin pump. Thirteen hospitals (65%) used long-term, real-time CGM systems in selected cases (a total of 67 patients). Use of these technologies in diabetes is unequal between public health care hospitals in Madrid, and is still significantly lower as compared to other countries with similar incomes. However, there appears to be a trend to an increase in their use. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  19. Autoregressive Modeling of Drift and Random Error to Characterize a Continuous Intravascular Glucose Monitoring Sensor.

    Science.gov (United States)

    Zhou, Tony; Dickson, Jennifer L; Geoffrey Chase, J

    2018-01-01

    Continuous glucose monitoring (CGM) devices have been effective in managing diabetes and offer potential benefits for use in the intensive care unit (ICU). Use of CGM devices in the ICU has been limited, primarily due to the higher point accuracy errors over currently used traditional intermittent blood glucose (BG) measures. General models of CGM errors, including drift and random errors, are lacking, but would enable better design of protocols to utilize these devices. This article presents an autoregressive (AR) based modeling method that separately characterizes the drift and random noise of the GlySure CGM sensor (GlySure Limited, Oxfordshire, UK). Clinical sensor data (n = 33) and reference measurements were used to generate 2 AR models to describe sensor drift and noise. These models were used to generate 100 Monte Carlo simulations based on reference blood glucose measurements. These were then compared to the original CGM clinical data using mean absolute relative difference (MARD) and a Trend Compass. The point accuracy MARD was very similar between simulated and clinical data (9.6% vs 9.9%). A Trend Compass was used to assess trend accuracy, and found simulated and clinical sensor profiles were similar (simulated trend index 11.4° vs clinical trend index 10.9°). The model and method accurately represents cohort sensor behavior over patients, providing a general modeling approach to any such sensor by separately characterizing each type of error that can arise in the data. Overall, it enables better protocol design based on accurate expected CGM sensor behavior, as well as enabling the analysis of what level of each type of sensor error would be necessary to obtain desired glycemic control safety and performance with a given protocol.

  20. Continuous glucose monitoring in newborn infants: how do errors in calibration measurements affect detected hypoglycemia?

    Science.gov (United States)

    Thomas, Felicity; Signal, Mathew; Harris, Deborah L; Weston, Philip J; Harding, Jane E; Shaw, Geoffrey M; Chase, J Geoffrey

    2014-05-01

    Neonatal hypoglycemia is common and can cause serious brain injury. Continuous glucose monitoring (CGM) could improve hypoglycemia detection, while reducing blood glucose (BG) measurements. Calibration algorithms use BG measurements to convert sensor signals into CGM data. Thus, inaccuracies in calibration BG measurements directly affect CGM values and any metrics calculated from them. The aim was to quantify the effect of timing delays and calibration BG measurement errors on hypoglycemia metrics in newborn infants. Data from 155 babies were used. Two timing and 3 BG meter error models (Abbott Optium Xceed, Roche Accu-Chek Inform II, Nova Statstrip) were created using empirical data. Monte-Carlo methods were employed, and each simulation was run 1000 times. Each set of patient data in each simulation had randomly selected timing and/or measurement error added to BG measurements before CGM data were calibrated. The number of hypoglycemic events, duration of hypoglycemia, and hypoglycemic index were then calculated using the CGM data and compared to baseline values. Timing error alone had little effect on hypoglycemia metrics, but measurement error caused substantial variation. Abbott results underreported the number of hypoglycemic events by up to 8 and Roche overreported by up to 4 where the original number reported was 2. Nova results were closest to baseline. Similar trends were observed in the other hypoglycemia metrics. Errors in blood glucose concentration measurements used for calibration of CGM devices can have a clinically important impact on detection of hypoglycemia. If CGM devices are going to be used for assessing hypoglycemia it is important to understand of the impact of these errors on CGM data. © 2014 Diabetes Technology Society.

  1. Assessing sensor accuracy for non-adjunct use of continuous glucose monitoring.

    Science.gov (United States)

    Kovatchev, Boris P; Patek, Stephen D; Ortiz, Edward Andrew; Breton, Marc D

    2015-03-01

    The level of continuous glucose monitoring (CGM) accuracy needed for insulin dosing using sensor values (i.e., the level of accuracy permitting non-adjunct CGM use) is a topic of ongoing debate. Assessment of this level in clinical experiments is virtually impossible because the magnitude of CGM errors cannot be manipulated and related prospectively to clinical outcomes. A combination of archival data (parallel CGM, insulin pump, self-monitoring of blood glucose [SMBG] records, and meals for 56 pump users with type 1 diabetes) and in silico experiments was used to "replay" real-life treatment scenarios and relate sensor error to glycemic outcomes. Nominal blood glucose (BG) traces were extracted using a mathematical model, yielding 2,082 BG segments each initiated by insulin bolus and confirmed by SMBG. These segments were replayed at seven sensor accuracy levels (mean absolute relative differences [MARDs] of 3-22%) testing six scenarios: insulin dosing using sensor values, threshold, and predictive alarms, each without or with considering CGM trend arrows. In all six scenarios, the occurrence of hypoglycemia (frequency of BG levels ≤50 mg/dL and BG levels ≤39 mg/dL) increased with sensor error, displaying an abrupt slope change at MARD =10%. Similarly, hyperglycemia (frequency of BG levels ≥250 mg/dL and BG levels ≥400 mg/dL) increased and displayed an abrupt slope change at MARD=10%. When added to insulin dosing decisions, information from CGM trend arrows, threshold, and predictive alarms resulted in improvement in average glycemia by 1.86, 8.17, and 8.88 mg/dL, respectively. Using CGM for insulin dosing decisions is feasible below a certain level of sensor error, estimated in silico at MARD=10%. In our experiments, further accuracy improvement did not contribute substantively to better glycemic outcomes.

  2. Translating Glucose Variability Metrics into the Clinic via Continuous Glucose Monitoring: A Graphical User Interface for Diabetes Evaluation (CGM-GUIDE©)

    Science.gov (United States)

    Rawlings, Renata A.; Shi, Hang; Yuan, Lo-Hua; Brehm, William; Pop-Busui, Rodica

    2011-01-01

    Abstract Background Several metrics of glucose variability have been proposed to date, but an integrated approach that provides a complete and consistent assessment of glycemic variation is missing. As a consequence, and because of the tedious coding necessary during quantification, most investigators and clinicians have not yet adopted the use of multiple glucose variability metrics to evaluate glycemic variation. Methods We compiled the most extensively used statistical techniques and glucose variability metrics, with adjustable hyper- and hypoglycemic limits and metric parameters, to create a user-friendly Continuous Glucose Monitoring Graphical User Interface for Diabetes Evaluation (CGM-GUIDE©). In addition, we introduce and demonstrate a novel transition density profile that emphasizes the dynamics of transitions between defined glucose states. Results Our combined dashboard of numerical statistics and graphical plots support the task of providing an integrated approach to describing glycemic variability. We integrated existing metrics, such as SD, area under the curve, and mean amplitude of glycemic excursion, with novel metrics such as the slopes across critical transitions and the transition density profile to assess the severity and frequency of glucose transitions per day as they move between critical glycemic zones. Conclusions By presenting the above-mentioned metrics and graphics in a concise aggregate format, CGM-GUIDE provides an easy to use tool to compare quantitative measures of glucose variability. This tool can be used by researchers and clinicians to develop new algorithms of insulin delivery for patients with diabetes and to better explore the link between glucose variability and chronic diabetes complications. PMID:21932986

  3. Limits to the Evaluation of the Accuracy of Continuous Glucose Monitoring Systems by Clinical Trials.

    Science.gov (United States)

    Schrangl, Patrick; Reiterer, Florian; Heinemann, Lutz; Freckmann, Guido; Del Re, Luigi

    2018-05-18

    Systems for continuous glucose monitoring (CGM) are evolving quickly, and the data obtained are expected to become the basis for clinical decisions for many patients with diabetes in the near future. However, this requires that their analytical accuracy is sufficient. This accuracy is usually determined with clinical studies by comparing the data obtained by the given CGM system with blood glucose (BG) point measurements made with a so-called reference method. The latter is assumed to indicate the correct value of the target quantity. Unfortunately, due to the nature of the clinical trials and the approach used, such a comparison is subject to several effects which may lead to misleading results. While some reasons for the differences between the values obtained with CGM and BG point measurements are relatively well-known (e.g., measurement in different body compartments), others related to the clinical study protocols are less visible, but also quite important. In this review, we present a general picture of the topic as well as tools which allow to correct or at least to estimate the uncertainty of measures of CGM system performance.

  4. Continuous operation of an ultra-low-power microcontroller using glucose as the sole energy source.

    Science.gov (United States)

    Lee, Inyoung; Sode, Takashi; Loew, Noya; Tsugawa, Wakako; Lowe, Christopher Robin; Sode, Koji

    2017-07-15

    An ultimate goal for those engaged in research to develop implantable medical devices is to develop mechatronic implantable artificial organs such as artificial pancreas. Such devices would comprise at least a sensor module, an actuator module, and a controller module. For the development of optimal mechatronic implantable artificial organs, these modules should be self-powered and autonomously operated. In this study, we aimed to develop a microcontroller using the BioCapacitor principle. A direct electron transfer type glucose dehydrogenase was immobilized onto mesoporous carbon, and then deposited on the surface of a miniaturized Au electrode (7mm 2 ) to prepare a miniaturized enzyme anode. The enzyme fuel cell was connected with a 100 μF capacitor and a power boost converter as a charge pump. The voltage of the enzyme fuel cell was increased in a stepwise manner by the charge pump from 330mV to 3.1V, and the generated electricity was charged into a 100μF capacitor. The charge pump circuit was connected to an ultra-low-power microcontroller. Thus prepared BioCapacitor based circuit was able to operate an ultra-low-power microcontroller continuously, by running a program for 17h that turned on an LED every 60s. Our success in operating a microcontroller using glucose as the sole energy source indicated the probability of realizing implantable self-powered autonomously operated artificial organs, such as artificial pancreas. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Glucose control in pregnant women with type 1 diabetes mellitus: Studies using a continuous glucose monitoring system

    NARCIS (Netherlands)

    Kerssen, Anneloes

    2005-01-01

    Pregnancy in women with type 1 diabetes mellitus is associated with neonatal morbidity. It is commonly agreed that the morbidity decreases when diabetic control is tightened. The most common methods for the determination of diabetic control are the self-monitoring of blood glucose levels (SMBG) and

  6. Differential effects of vildagliptin and glimepiride on glucose fluctuations in patients with type 2 diabetes mellitus assessed using continuous glucose monitoring.

    Science.gov (United States)

    He, Y L; Foteinos, G; Neelakantham, S; Mattapalli, D; Kulmatycki, K; Forst, T; Taylor, A

    2013-12-01

    To assess whether there is a difference in the effects of vildagliptin and glimepiride on glucose fluctuation in patients with type 2 diabetes mellitus (T2DM) using continuous glucose monitoring (CGM). This was an open-label, randomized cross-over study conducted in T2DM patients. A total of 24 patients (age: 58.3 ± 5.56 years, baseline HbA1c: 7.6 ± 0.50%) who were on stable metformin monotherapy (500-3000 mg) were enrolled, and all completed the study. Each patient received two 5-day treatments (vildagliptin 50 mg b.i.d. or glimepiride 2 mg q.d.) in a cross-over manner. Various biomarkers and blood glucose concentrations were measured following breakfast. The 24-h glucose profiles were also measured using the CGM device at baseline and after 5 days of treatment, and fluctuations in glucose levels were estimated from CGM data. Both vildagliptin and glimepiride reduced postprandial glucose levels, based on both CGM data (15% vs. 16%) and measured plasma glucose (13% vs.17%). Vildagliptin showed lower glucose fluctuations than glimepiride as measured by mean amplitude of glycaemic excursions (MAGE, p = 0.1076), standard deviation (s.d., p = 0.1346) of blood glucose rate of change, but did not reach statistical significance attributed to the small sample size. MAGE was reduced by ∼20% with vildagliptin versus glimepiride. Vildagliptin led to statistically significant lowering of the rate of change in the median curve (RCMC) and interquartile range (IQR) of glucose. Treatment with vildagliptin significantly increased the levels of active glucagon-like peptide-1 by 2.36-fold (p ≤ 0.0001) and suppressed glucagon by 8% (p = 0.01), whereas glimepiride significantly increased the levels of insulin and C-peptide by 21% (p = 0.012) and 12% (p = 0.003), respectively. Vildagliptin treatment was associated with less fluctuation of glucose levels than glimepiride treatment as assessed by 24-h CGM device, suggesting vildagliptin may

  7. Early Glucose Derangement Detected by Continuous Glucose Monitoring and Progression of Liver Fibrosis in Nonalcoholic Fatty Liver Disease: An Independent Predictive Factor?

    Science.gov (United States)

    Schiaffini, Riccardo; Liccardo, Daniela; Alisi, Anna; Benevento, Danila; Cappa, Marco; Cianfarani, Stefano; Nobili, Valerio

    2016-01-01

    Glucose derangement has been reported to increase oxidative stress, one of the most important factors underlying the progression of hepatic fibrosis in adults with nonalcoholic fatty liver disease (NAFLD). To date, careful evaluation of the glucose profile in pediatric NAFLD has not been performed. A total of 30 severely obese children (15 males; mean age 12.87 ± 2.19 years) with biopsy-proven NAFLD were enrolled in this study from September to December 2013. All patients underwent anthropometric and laboratory evaluation, including the oral glucose tolerance test (OGTT) and continuous glucose monitoring (CGM). Our study reveals some differences between OGTT and CGM in detecting NAFLD children with impaired fasting glucose (IFG) and impaired glucose tolerance (IGT). OGTT showed 2 (6.67%) patients with IFG and 1 (3.34%) with IGT, while CGM showed 5 (16.67%) patients with IFG and 6 (20%) with IGT. The daily blood glucose profile positively correlated with the baseline blood glucose (r = 0.39, p = 0.04) and the homeostatic model assessment (r = 0.56, p = 0.05). A positive correlation between hyperglycemia and liver fibrosis was found (r = 0.65, p < 0.05). Mean glucose values (F3-F4 group: 163.2 ± 35.92 mg/dl vs. F1 group: 136.58 ± 46.83 mg/dl and F2 group: 154.12 ± 22.51 mg/dl) and the difference between the minimum and maximum blood glucose levels (F3-F4 group: 110.21 ± 25.26 mg/dl vs. F1 group: 91.67 ± 15.97 mg/dl and F2 group: 92 ± 15.48 mg/dl) were significantly (p < 0.05) higher in the F3-F4 group compared to the F1 and F2 groups. Glucose profile derangement as detected by CGM is associated with the severity of hepatic fibrosis in children with NAFLD. © 2015 S. Karger AG, Basel.

  8. Hypoglycemic Exposure and Risk of Asymptomatic Hypoglycemia in Type 1 Diabetes assessed by Continuous Glucose Monitoring

    DEFF Research Database (Denmark)

    Henriksen, Marie Moth; Andersen, Henrik Ullits; Thorsteinsson, Birger

    2018-01-01

    : To explore the association between hypoglycemic exposure and proportion of asymptomatic hypoglycemia and relation to risk of severe hypoglycemia. Design: Prospective observational trial. Setting: Outpatient clinic. Patients: 153 unselected subjects with type 1 diabetes mellitus (T1D). Intervention: Six days...... of blinded continuous glucose monitoring (CGM) and recording of hypoglycemia symptoms. Main Outcome Measure: Proportion of asymptomatic hypoglycemic events (≤70 mg/dl). Results: Patients were grouped by the number of hypoglycemic events during the recording period (group 1: 1 event, group 2: 2-3 events...... positively associated with risk of severe hypoglycemia (incidence rate ratio (IRR) 1.3 (95% CI 1.1-1.5); p=0.003). Group 4 consisted of patients characterized by classical risk factors of severe hypoglycemia (longer duration of diabetes, lower HbA1c and more frequent impaired awareness of hypoglycemia...

  9. Continuous Glucose Monitoring: Current Use in Diabetes Management and Possible Future Applications.

    Science.gov (United States)

    Vettoretti, Martina; Cappon, Giacomo; Acciaroli, Giada; Facchinetti, Andrea; Sparacino, Giovanni

    2018-05-01

    The recent announcement of the production of new low-cost continuous glucose monitoring (CGM) sensors, the approval of marketed CGM sensors for making treatment decisions, and new reimbursement criteria have the potential to revolutionize CGM use. After briefly summarizing current CGM applications, we discuss how, in our opinion, these changes are expected to extend CGM utilization beyond diabetes patients, for example, to subjects with prediabetes or even healthy individuals. We also elaborate on how the integration of CGM data with other relevant information, for example, health records and other medical device/wearable sensor data, will contribute to creating a digital data ecosystem that will improve our understanding of the etiology and complications of diabetes and will facilitate the development of data analytics for personalized diabetes management and prevention.

  10. Peculiarities of the Continuous Glucose Monitoring Data Stream and Their Impact on Developing Closed-Loop Control Technology

    OpenAIRE

    Kovatchev, Boris; Clarke, William

    2008-01-01

    Therapeutic advances in type 1 diabetes (T1DM) are currently focused on developing a closed-loop control system using a continuous glucose monitor (CGM), subcutaneous insulin delivery, and a control algorithm. Because a CGM assesses blood glucose indirectly (and therefore often inaccurately), it limits the effectiveness of the controller. In order to improve the quality of CGM data, a series of analyses are suggested. These analyses evaluate and compensate for CGM errors, assess risks associa...

  11. Epidemiological characterization of diabetic patients on therapy with continuous subcutaneous insulin infusion and continuous glucose monitoring in real time.

    Science.gov (United States)

    Aristizábal, Natalia; Ramírez, Alex; Hincapié-García, Jaime; Laiton, Estefany; Aristizábal, Carolina; Cuesta, Diana; Monsalve, Claudia; Hincapié, Gloria; Zapata, Eliana; Abad, Verónica; Delgado, Maria-Rocio; Torres, José-Luis; Palacio, Andrés; Botero, José

    2015-11-01

    To describe baseline characteristics of diabetic patients who were started on insulin pump and real time continuous glucose monitor (CSII-rtCGM) in a specialized center in Medellin, Colombia. All patients with diabetes with complete data who were started on CSII-rtCGM between February 2010 and May 2014 were included. This is a descriptive analysis of the sociodemographic and clinical characteristics. 141 of 174 patients attending the clinic were included. 90,1% had type 1diabetes (T1D). The average age of T1D patients at the beginning of therapy was 31,4 years (SD 14,1). 75.8% of patients had normal weight (BMI30). The median duration of T1D was 13 years (P25-P75=10.7-22.0). 14,2% of the patients were admitted at least once in the year preceding the start of CSII-rtCGM because of diabetes related complications. Mean A1c was 8.6%±1.46%. The main reasons for starting CSII-rtCGM were: poor glycemic control (50.2%); frequent hypoglycemia, nocturnal hypoglycemia, hypoglycemia related to exercise, asymptomatic hypoglycemia (30.2%); severe hypoglycemia (16.44%) and dawn phenomena (3.1%). Baseline characteristics of patients included in this study who were started on CSII-rtCGM are similar to those reported in the literature. The Clinic starts CSII-rtCGM mainly in T1D patients with poor glycemic control, frequent or severe hypoglycemia despite being on basal/bolus therapy. Copyright © 2015 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  12. Continuous glucose monitoring and HbA1c in the evaluation of glucose metabolism in children at high risk for type 1 diabetes mellitus.

    Science.gov (United States)

    Helminen, Olli; Pokka, Tytti; Tossavainen, Päivi; Ilonen, Jorma; Knip, Mikael; Veijola, Riitta

    2016-10-01

    Continuous glucose monitoring (CGM) parameters, self-monitored blood glucose (SMBG), HbA1c and oral glucose tolerance test (OGTT) were studied during preclinical type 1 diabetes mellitus. Ten asymptomatic children with multiple (⩾2) islet autoantibodies (cases) and 10 age and sex-matched autoantibody-negative controls from the Type 1 Diabetes Prediction and Prevention (DIPP) Study were invited to 7-day CGM with Dexcom G4 Platinum Sensor. HbA1c and two daily SMBG values (morning and evening) were analyzed. Five-point OGTTs were performed and carbohydrate intake was assessed by food records. The matched pairs were compared with the paired sample t-test. The cases showed higher mean values and higher variation in glucose levels during CGM compared to the controls. The time spent ⩾7.8mmol/l was 5.8% in the cases compared to 0.4% in the controls (p=0.040). Postprandial CGM values were similar except after the dinner (6.6mmol/l in cases vs. 6.1mmol/l in controls; p=0.023). When analyzing the SMBG values higher mean level, higher evening levels, as well as higher variation were observed in the cases when compared to the controls. HbA1c was significantly higher in the cases [5.7% (39mmol/mol) vs. 5.3% (34mmol/mol); p=0.045]. No differences were observed in glucose or C-peptide levels during OGTT. Daily carbohydrate intake was slightly higher in the cases (254.2g vs. 217.7g; p=0.034). Glucose levels measured by CGM and SMBG are useful indicators of dysglycemia during preclinical type 1 diabetes mellitus. Increased evening glucose values seem to be common in children with preclinical type 1 diabetes mellitus. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients.

    Science.gov (United States)

    Uemura, Mei; Yano, Yutaka; Suzuki, Toshinari; Yasuma, Taro; Sato, Toshiyuki; Morimoto, Aya; Hosoya, Samiko; Suminaka, Chihiro; Nakajima, Hiromu; Gabazza, Esteban C; Takei, Yoshiyuki

    2017-08-01

    Continuous glucose monitoring (CGM) is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC) monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET). Here we evaluated the accuracy of interstitial fluid glucose (IG) AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference. Thirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. A significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76) and nighttime (r=0.82). The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity. We showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day. Copyright © 2017 Korean Diabetes Association

  14. Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients

    Directory of Open Access Journals (Sweden)

    Mei Uemura

    2017-07-01

    Full Text Available BackgroundContinuous glucose monitoring (CGM is reported to be a useful technique, but difficult or inconvenient for some patients and institutions. We are developing a glucose area under the curve (AUC monitoring system without blood sampling using a minimally invasive interstitial fluid extraction technology (MIET. Here we evaluated the accuracy of interstitial fluid glucose (IG AUC measured by MIET in patients with diabetes for an extended time interval and the potency of detecting hyperglycemia using CGM data as a reference.MethodsThirty-eight inpatients with diabetes undergoing CGM were enrolled. MIET comprised a pretreatment step using a plastic microneedle array and glucose accumulation step with a hydrogel patch, which was placed on two sites from 9:00 AM to 5:00 PM or from 10:00 PM to 6:00 AM. IG AUC was calculated by accumulated glucose extracted by hydrogel patches using sodium ion as standard. ResultsA significant correlation was observed between the predicted AUC by MIET and CGM in daytime (r=0.76 and nighttime (r=0.82. The optimal cutoff for the IG AUC value of MIET to predict hyperglycemia over 200 mg/dL measured by CGM for 8 hours was 1,067.3 mg·hr/dL with 88.2% sensitivity and 81.5% specificity.ConclusionWe showed that 8-hour IG AUC levels using MIET were valuable in estimating the blood glucose AUC without blood sampling. The results also supported the concept of using this technique for evaluating glucose excursion and for screening hyperglycemia during 8 hours in patients with diabetes at any time of day.

  15. Real-time continuous glucose monitoring during labour and delivery in women with Type 1 diabetes — observations from a randomized controlled trial

    DEFF Research Database (Denmark)

    Cordua, S; Secher, A L; Ringholm, L

    2013-01-01

    To explore whether real-time continuous glucose monitoring during labour and delivery supplementary to hourly self-monitored plasma glucose in women with Type 1 diabetes reduces the prevalence of neonatal hypoglycaemia.......To explore whether real-time continuous glucose monitoring during labour and delivery supplementary to hourly self-monitored plasma glucose in women with Type 1 diabetes reduces the prevalence of neonatal hypoglycaemia....

  16. Hydrogel-based electrochemical sensor for non-invasive and continuous glucose monitoring

    Science.gov (United States)

    Park, Habeen; Lee, Ji-Young; Kim, Dong-Chul; Koh, Younggook; Cha, Junhoe

    2017-07-01

    Monitoring blood glucose level of diabetic patients is crucial in diabetes care from life threating complications. Selfmonitoring blood glucose (SMBG) that involves finger prick to draw blood samples into the measurement system is a widely-used method of routine measurement of blood glucose levels to date. SMBG includes, however, unavoidable pain problems resulting from the repetitive measurements. We hereby present a hydrogel-based electrochemical (H-EC) sensor to monitor the glucose level, non-invasively. Glucose oxidase (GOx) was immobilized in the disc-type hydroxyethyl methacrylate (HEMA) based hydrogel and kept intact in the hydrogel. Fast electron transfer mediated by Prussian blue (PB, hexacyanoferrate) generated efficient signal amplifications to facilitate the detection of the extracted glucose from the interstitial fluid. The linear response and the selectivity against glucose of the H-EC sensor were validated by chronoamperometry. For the practical use, the outcomes from the correlation of the extracted glucose concentration and the blood glucose value by on-body extraction, as well as the validation of the hydrogel-based electrochemical (H-EC) device, were applied to the on-body glucose monitoring.

  17. Real-time continuous glucose monitoring shows high accuracy within 6 hours after sensor calibration: a prospective study.

    Directory of Open Access Journals (Sweden)

    Xiao-Yan Yue

    Full Text Available Accurate and timely glucose monitoring is essential in intensive care units. Real-time continuous glucose monitoring system (CGMS has been advocated for many years to improve glycemic management in critically ill patients. In order to determine the effect of calibration time on the accuracy of CGMS, real-time subcutaneous CGMS was used in 18 critically ill patients. CGMS sensor was calibrated with blood glucose measurements by blood gas/glucose analyzer every 12 hours. Venous blood was sampled every 2 to 4 hours, and glucose concentration was measured by standard central laboratory device (CLD and by blood gas/glucose analyzer. With CLD measurement as reference, relative absolute difference (mean±SD in CGMS and blood gas/glucose analyzer were 14.4%±12.2% and 6.5%±6.2%, respectively. The percentage of matched points in Clarke error grid zone A was 74.8% in CGMS, and 98.4% in blood gas/glucose analyzer. The relative absolute difference of CGMS obtained within 6 hours after sensor calibration (8.8%±7.2% was significantly less than that between 6 to 12 hours after calibration (20.1%±13.5%, p<0.0001. The percentage of matched points in Clarke error grid zone A was also significantly higher in data sets within 6 hours after calibration (92.4% versus 57.1%, p<0.0001. In conclusion, real-time subcutaneous CGMS is accurate in glucose monitoring in critically ill patients. CGMS sensor should be calibrated less than 6 hours, no matter what time interval recommended by manufacturer.

  18. Evaluation of an open access software for calculating glucose variability parameters of a continuous glucose monitoring system applied at pediatric intensive care unit.

    Science.gov (United States)

    Marics, Gábor; Lendvai, Zsófia; Lódi, Csaba; Koncz, Levente; Zakariás, Dávid; Schuster, György; Mikos, Borbála; Hermann, Csaba; Szabó, Attila J; Tóth-Heyn, Péter

    2015-04-24

    Continuous Glucose Monitoring (CGM) has become an increasingly investigated tool, especially with regards to monitoring of diabetic and critical care patients. The continuous glucose data allows the calculation of several glucose variability parameters, however, without specific application the interpretation of the results is time-consuming, utilizing extreme efforts. Our aim was to create an open access software [Glycemic Variability Analyzer Program (GVAP)], readily available to calculate the most common parameters of the glucose variability and to test its usability. The GVAP was developed in MATLAB® 2010b environment. The calculated parameters were the following: average area above/below the target range (Avg. AUC-H/L); Percentage Spent Above/Below the Target Range (PATR/PBTR); Continuous Overall Net Glycemic Action (CONGA); Mean of Daily Differences (MODD); Mean Amplitude of Glycemic Excursions (MAGE). For verification purposes we selected 14 CGM curves of pediatric critical care patients. Medtronic® Guardian® Real-Time with Enlite® sensor was used. The reference values were obtained from Medtronic®(')s own software for Avg. AUC-H/L and PATR/PBTR, from GlyCulator for MODD and CONGA, and using manual calculation for MAGE. The Pearson and Spearman correlation coefficients were above 0.99 for all parameters. The initial execution took 30 minutes, for further analysis with the Windows® Standalone Application approximately 1 minute was needed. The GVAP is a reliable open access program for analyzing different glycemic variability parameters, hence it could be a useful tool for the study of glycemic control among critically ill patients.

  19. Continuous-time interval model identification of blood glucose dynamics for type 1 diabetes

    Science.gov (United States)

    Kirchsteiger, Harald; Johansson, Rolf; Renard, Eric; del Re, Luigi

    2014-07-01

    While good physiological models of the glucose metabolism in type 1 diabetic patients are well known, their parameterisation is difficult. The high intra-patient variability observed is a further major obstacle. This holds for data-based models too, so that no good patient-specific models are available. Against this background, this paper proposes the use of interval models to cover the different metabolic conditions. The control-oriented models contain a carbohydrate and insulin sensitivity factor to be used for insulin bolus calculators directly. Available clinical measurements were sampled on an irregular schedule which prompts the use of continuous-time identification, also for the direct estimation of the clinically interpretable factors mentioned above. An identification method is derived and applied to real data from 28 diabetic patients. Model estimation was done on a clinical data-set, whereas validation results shown were done on an out-of-clinic, everyday life data-set. The results show that the interval model approach allows a much more regular estimation of the parameters and avoids physiologically incompatible parameter estimates.

  20. Real-time continuous glucose monitoring systems in the classroom/school environment.

    Science.gov (United States)

    Benassi, Kari; Drobny, Jessica; Aye, Tandy

    2013-05-01

    Children with type 1 diabetes (T1D) spend 4-7 h/day in school with very little supervision of their diabetes management. Therefore, families have become more dependent on technology, such as use of real-time continuous glucose monitoring (RT-CGM), to provide increased supervision of their diabetes management. We sought to assess the impact of RT-CGM use in the classroom/school environment. Children with T1D using RT-CGM, their parents, and teachers completed a questionnaire about RT-CGM in the classroom/school environment. The RT-CGM was tolerated well in the classroom/school environment. Seventy percent of parents, 75% of students, and 51% of teachers found RT-CGM useful in the classroom/school environment. The students found the device to be more disruptive than did their parents and teachers. However, all three groups agreed that RT-CGM increased their comfort with diabetes management at school. Our study suggests that RT-CGM is useful and not disruptive in the classroom/school environment. The development of education materials for teachers could further increase its acceptance in the classroom/school environment.

  1. Wireless connection of continuous glucose monitoring system to the electronic patient record

    Science.gov (United States)

    Murakami, Alexandre; Gutierrez, Marco A.; Lage, Silvia G.; Rebelo, Marina S.; Granja, Luiz A. R.; Ramires, Jose A. F.

    2005-04-01

    The control of blood sugar level (BSL) at near-normal levels has been documented to reduce both acute and chronic complications of diabetes mellitus. Recent studies suggested, the reduction of mortality in a surgical intensive care unit (ICU), when the BSL are maintained at normal levels. Despite of the benefits appointed by these and others clinical studies, the strict BSL control in critically ill patients suffers from some difficulties: a) medical staff need to measure and control the patient"s BSL using blood sample at least every hour. This is a complex and time consuming task; b) the inaccuracy of standard capillary glucose monitoring (fingerstick) in hypotensive patients and, if frequently used to sample arterial or venous blood, may lead to excess phlebotomy; c) there is no validated procedure for continuously monitoring of BSL levels. This study used the MiniMed CGMS in ill patients at ICU to send, in real-time, BSL values to a Web-Based Electronic Patient Record. The BSL values are parsed and delivered through a wireless network as an HL7 message. The HL7 messages with BSL values are collected, stored into the Electronic Patient Record and presented into a bed-side monitor at the ICU together with other relevant patient information.

  2. Continuous glucose monitoring technology for personal use: an educational program that educates and supports the patient.

    Science.gov (United States)

    Evert, Alison; Trence, Dace; Catton, Sarah; Huynh, Peter

    2009-01-01

    The purpose of this article is to describe the development and implementation of an educational program for the initiation of real-time continuous glucose monitoring (CGM) technology for personal use, not 3-day CGMS diagnostic studies. The education program was designed to meet the needs of patients managing their diabetes with either diabetes medications or insulin pump therapy in an outpatient diabetes education center using a team-based approach. Observational research, complemented by literature review, was used to develop an educational program model and teaching strategies. Diabetes educators, endocrinologists, CGM manufacturer clinical specialists, and patients with diabetes were also interviewed for their clinical observations and experience. The program follows a progressive educational model. First, patients learn in-depth about real-time CGM technology by attending a group presensor class that provides detailed information about CGM. This presensor class facilitates self-selection among patients concerning their readiness to use real-time CGM. If the patient decides to proceed with real-time CGM use, CGM initiation is scheduled, using a clinic-centered protocol for both start-up and follow-up. Successful use of real-time CGM involves more than just patient enthusiasm or interest in a new technology. Channeling patient interest into a structured educational setting that includes the benefits and limitations of real-time CGM helps to manage patient expectations.

  3. Data-driven strategies for robust forecast of continuous glucose monitoring time-series.

    Science.gov (United States)

    Fiorini, Samuele; Martini, Chiara; Malpassi, Davide; Cordera, Renzo; Maggi, Davide; Verri, Alessandro; Barla, Annalisa

    2017-07-01

    Over the past decade, continuous glucose monitoring (CGM) has proven to be a very resourceful tool for diabetes management. To date, CGM devices are employed for both retrospective and online applications. Their use allows to better describe the patients' pathology as well as to achieve a better control of patients' level of glycemia. The analysis of CGM sensor data makes possible to observe a wide range of metrics, such as the glycemic variability during the day or the amount of time spent below or above certain glycemic thresholds. However, due to the high variability of the glycemic signals among sensors and individuals, CGM data analysis is a non-trivial task. Standard signal filtering solutions fall short when an appropriate model personalization is not applied. State-of-the-art data-driven strategies for online CGM forecasting rely upon the use of recursive filters. Each time a new sample is collected, such models need to adjust their parameters in order to predict the next glycemic level. In this paper we aim at demonstrating that the problem of online CGM forecasting can be successfully tackled by personalized machine learning models, that do not need to recursively update their parameters.

  4. Continuous Blood Glucose Monitoring May Detect Carotid Occlusion Intolerance during Carotid Artery Stenting.

    Science.gov (United States)

    Hiramatsu, Ryo; Furuse, Motomasa; Yagi, Ryokichi; Ohmura, Tomohisa; Ohnishi, Hiroyuki; Ikeda, Naokado; Nonoguchi, Naosuke; Kawabata, Shinji; Miyachi, Shigeru; Kuroiwa, Toshihiko

    2018-02-05

    The frequency of the occurrence of adverse events associated with carotid artery stenting (CAS) is usually low, but serious adverse events such as cerebral hyperperfusion syndrome (CHS) may occur. Real-time monitoring is ideal for the early detection of adverse events during the surgical procedure. This study aimed to evaluate continuous blood glucose (BG) monitoring for the detection of adverse events during CAS. Forty patients undergoing scheduled CAS were prospectively enrolled. An artificial pancreas was used for continuous BG monitoring (once per minute), using venous blood extracted at a rate of 2 mL/hr during CAS. The primary endpoint was a correlation between BG change and adverse events. CAS was discontinued in 1 patient, and BG was not measured in 5 patients (12.5%) because of the inability to extract blood. Among 34 evaluable patients, no patient developed CHS, but 3 patients (9%) experienced carotid occlusion intolerance. During CAS, BG was significantly higher in patients with carotid occlusion intolerance (median: 5 mg/dL) than in patients without carotid occlusion intolerance (median: 0 mg/dL) (P = 0.0221). A cutoff BG value ≥4 mg/dL during CAS showed 50% sensitivity and 100% specificity for the detection of carotid occlusion intolerance. There was no significant correlation between BG change and other adverse events. BG elevation may help detect carotid occlusion intolerance although it is still unknown whether BG monitoring can detect CHS. Further studies should validate that a cutoff BG elevation value of ≥4 mg/dL during CAS indicates carotid occlusion intolerance. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Production of extracellular protease and glucose uptake in Bacillus clausii in steady-state and transient continuous cultures

    DEFF Research Database (Denmark)

    Christiansen, Torben; Nielsen, Jens

    2002-01-01

    The production of the extracellular alkaline protease Savinase(R) (EC 3.4.21.62) and glucose uptake in a non-sporulating strain of Bacillus clausii were investigated by analysing steady-state and transients during continuous cultivations. The specific production rate was found to have an optimum...

  6. Nocturnal hypoglycemia identified by a continuous glucose monitoring system in patients with primary adrenal insufficiency (Addison's Disease).

    Science.gov (United States)

    Meyer, Gesine; Hackemann, Annika; Reusch, Juergen; Badenhoop, Klaus

    2012-05-01

    Hypoglycemia can be a symptom in patients with Addison's disease. The common regimen of replacement therapy with oral glucocorticoids results in unphysiological low cortisol levels in the early morning, the time of highest insulin sensitivity. Therefore patients with Addison's disease are at risk for unrecognized and potentially severe nocturnal hypoglycemia also because of a disturbed counterregulatory function. Use of a continuous glucose monitoring system (CGMS) could help to adjust hydrocortisone treatment and to avoid nocturnal hypoglycemia in these patients. Thirteen patients with Addison's disease were screened for hypoglycemia wearing a CGMS for 3-5 days. In one patient we identified a hypoglycemic episode at 3:45 a.m. with a blood glucose level of 46 mg/dL, clearly beneath the 95% tolerance interval of minimal glucose levels between 2 and 4 a.m. (53.84 mg/dL). After the hydrocortisone replacement scheme was changed, the minimum blood glucose level between 2 and 4 a.m. normalized to 87 mg/dL. Continuous glucose monitoring can detect nocturnal hypoglycemia in patients with primary adrenal insufficiency and hence prevent in these patients an impaired quality of life and even serious adverse effects.

  7. Optimal insulin pump dosing and postprandial glycemia following a pizza meal using the continuous glucose monitoring system.

    Science.gov (United States)

    Jones, Susan M; Quarry, Jill L; Caldwell-McMillan, Molly; Mauger, David T; Gabbay, Robert A

    2005-04-01

    We attempted to identify an optimal insulin pump meal bolus by comparing postprandial sensor glucose values following three methods of insulin pump meal bolusing for a consistent pizza meal. Twenty-four patients with type 1 diabetes participated in a study to compare postprandial glucose values following three meal bolus regimens for a consistent evening pizza meal. Each participant utilized the following insulin lispro regimens on consecutive evenings, and glucose values were tracked by the Continuous Glucose Monitoring System (CGMS, Medtronic MiniMed, Northridge, CA): (a) single-wave bolus (100% of insulin given immediately); (b) 4-h dual-wave bolus (50% of insulin given immediately and 50% given over a 4-h period); and (c) 8-h dual-wave bolus (50% of insulin given immediately and 50% given over a 8-h period). Total insulin bolus amount was kept constant for each pizza meal. Divergence in blood glucose among the regimens was greatest at 8-12 h. The 8-h dual-wave bolus provided the best glycemic control and lowest mean glucose values (singlewave bolus, 133 mg/dL; 4-h dual-wave bolus, 145 mg/dL; 8-h dual-wave bolus, 104 mg/dL), leading to a difference in mean glucose of 29 mg/dL for the single-wave bolus versus the 8-h dual-wave bolus and 42 mg/dL for the 4-h dual-wave bolus versus the 8-h dual-wave bolus. The lower mean glucose in the 8-h dual-wave bolus was not associated with any increased incidence of hypoglycemia. Use of a dual-wave bolus extended over an 8-h period following a pizza meal provided significantly less postprandial hyperglycemia in the late postprandial period (8-12 h) with no increased risk of hypoglycemia.

  8. Accuracy of Continuous Glucose Monitoring (CGM) during Continuous and High-Intensity Interval Exercise in Patients with Type 1 Diabetes Mellitus.

    Science.gov (United States)

    Moser, Othmar; Mader, Julia K; Tschakert, Gerhard; Mueller, Alexander; Groeschl, Werner; Pieber, Thomas R; Koehler, Gerd; Messerschmidt, Janin; Hofmann, Peter

    2016-08-10

    Continuous exercise (CON) and high-intensity interval exercise (HIIE) can be safely performed with type 1 diabetes mellitus (T1DM). Additionally, continuous glucose monitoring (CGM) systems may serve as a tool to reduce the risk of exercise-induced hypoglycemia. It is unclear if CGM is accurate during CON and HIIE at different mean workloads. Seven T1DM patients performed CON and HIIE at 5% below (L) and above (M) the first lactate turn point (LTP₁), and 5% below the second lactate turn point (LTP₂) (H) on a cycle ergometer. Glucose was measured via CGM and in capillary blood (BG). Differences were found in comparison of CGM vs. BG in three out of the six tests (p exercise-induced hypoglycemia, but usual BG control should be performed during intense exercise.

  9. Professional continuous glucose monitoring for the identification of type 1 diabetes mellitus among subjects with insulin therapy.

    Science.gov (United States)

    Chen, Yin-Chun; Huang, Yu-Yao; Li, Hung-Yuan; Liu, Shih-Wei; Hsieh, Sheng-Hwu; Lin, Chia-Hung

    2015-01-01

    The identification of type 1 diabetes in diabetic subjects receiving insulin therapy is sometimes difficult. The purpose of this study is to evaluate whether results of professional continuous glucose monitoring can improve the identification of type 1 diabetes.From 2007 to 2012, 119 adults receiving at least twice-daily insulin therapy and professional continuous glucose monitoring were recruited. Type 1 diabetes was diagnosed by endocrinologists according to American Diabetes Association standards, including a very low C-peptide level (diabetic ketoacidosis. Continuous glucose monitoring was applied for 3 days.Among 119 subjects, 86 were diagnosed with type 1 diabetes. Subjects with type 1 diabetes were younger (33.8 vs 52.3 years old, P 1), had lower body mass index (BMI, 21.95 vs 24.42, P = 0.003), lower serum creatinine (61.77  vs 84.65 μmol/L, P = 0.001), and higher estimated glomerular filtration rate (108.71 vs 76.48 mg/mL/min/1.73m2, P 1) than subjects with type 2 diabetes. Predictive scores for identification of type 1 diabetes were constructed, including age, BMI, average mean amplitude of glucose excursion in days 2 and 3, and the area under the curve of nocturnal hyperglycemic and hypoglycemic states. The area under the receiver operating characteristic curve was 0.90. With the cutoff of 0.58, the sensitivity was 86.7% and the specificity was 80.8%. The good performance was validated by the leave-one-out method (sensitivity 83.3%, specificity 73.1%).Professional continuous glucose monitoring is a useful tool that improves identification of type 1 diabetes among diabetic patients receiving insulin therapy.

  10. Continuous sensing of hydrogen peroxide and glucose via quenching of the UV and visible luminescence of ZnO nanoparticles

    International Nuclear Information System (INIS)

    Sodzel, Dzmitry; Kolesneva, Ekaterina; Dubovskaya, Lyudmila; Volotovski, Igor; Khranovskyy, Volodymyr; Eriksson, Martin O.; Holtz, Per-Olof; Yakimova, Rositsa; Beni, Valerio; Turner, Anthony P. F.; Ubelis, Arnolds; Smyntyna, Valentyn; Viter, Roman; Janot, Jean-Marc; Bechelany, Mikhael; Balme, Sebastien

    2015-01-01

    We report on an indirect optical method for the determination of glucose via the detection of hydrogen peroxide (H 2 O 2 ) that is generated during the glucose oxidase (GOx) catalyzed oxidation of glucose. It is based on the finding that the ultraviolet (∼374 nm) and visible (∼525 nm) photoluminescence of pristine zinc oxide (ZnO) nanoparticles strongly depends on the concentration of H 2 O 2 in water solution. Photoluminescence is quenched by up to 90 % at a 100 mM level of H 2 O 2 . The sensor constructed by immobilizing GOx on ZnO nanoparticles enabled glucose to be continuously monitored in the 10 mM to 130 mM concentration range, and the limit of detection is 10 mM. This enzymatic sensing scheme is supposed to be applicable to monitoring glucose in the food, beverage and fermentation industries. It has a wide scope in that it may be extended to numerous other substrate or enzyme activity assays based on the formation of H 2 O 2 , and of assays based on the consumption of H 2 O 2 by peroxidases. (author)

  11. First step toward near-infrared continuous glucose monitoring: in vivo evaluation of antibody coupled biomaterials

    Science.gov (United States)

    Gellynck, Karolien; Kodeck, Valérie; Van De Walle, Elke; Kersemans, Ken; De Vos, Filip; Declercq, Heidi; Dubruel, Peter; Vlaminck, Lieven

    2015-01-01

    Continuous glucose monitoring (CGM) is crucial in diabetic care. Long-term CGM systems however require an accurate sensor as well as a suitable measuring environment. Since large intravenous sensors are not feasible, measuring inside the interstitial fluid is considered the best alternative. This option, unfortunately, has the drawback of a lag time with blood glucose values. A good strategy to circumvent this is to enhance tissue integration and enrich the peri-implant vasculature. Implants of different optically transparent biomaterials (poly(methyl-methacrylate) [PMMA] and poly(dimethylsiloxane) [PDMS]) – enabling glucose monitoring in the near-infrared (NIR) spectrum – were surface-treated and subsequently implanted in goats at various implantation sites for up to 3 months. The overall in vivo biocompatibility, tissue integration, and vascularization at close proximity of the surfaces of these materials were assessed. Histological screening showed similar tissue reactions independent of the implantation site. No significant inflammation reaction was observed. Tissue integration and vascularization correlated, to some extent, with the biomaterial composition. A modification strategy, in which a vascular endothelial-cadherin antibody was coupled to the biomaterials surface through a dopamine layer, showed significantly enhanced vascularization 3 months after subcutaneous implantation. Our results suggest that the developed strategy enables the creation of tissue interactive NIR transparent packaging materials, opening the possibility of continuous glucose monitoring. PMID:25304314

  12. Differential photoacoustic spectroscopy with continuous wave lasers for non-invasive blood glucose monitoring

    Science.gov (United States)

    Tanaka, Y.; Tajima, T.; Seyama, M.

    2018-02-01

    We propose a differential photoacoustic spectroscopy (PAS), wherein two wavelengths of light with the same absorbance are selected, and differential signal is linearized by one of the two signals for a non-invasive blood glucose monitoring. PAS has the possibility to overcome the strong optical scattering in tissue, but there are still remaining issues: the water background and instability due to the variation in acoustic resonance conditions. A change in sample solution temperature is one of the causes of the variation in acoustic resonance conditions. Therefore, in this study, we investigated the sensitivity against glucose concentration under the condition where the temperature of the sample water solution ranges 30 to 40 °C. The glucose concentration change is simulated by shifting the wavelength of irradiated laser light, which can effectively change optical absorption. The temperature also affects optical absorption and the acoustic resonance condition (acoustic velocity). A distributed-feedback (DFB) laser, tunable wavelength laser (TWL) and an acoustic sensor were used to obtain the differential PAS signal. The wavelength of the DFB laser was 1.382 μm, and that of TWL was switched from 1.600 to 1.610 μm to simulate the glucose concentration change. Optical absorption by glucose occurs at around 1.600 μm. The sensitivities against temperature are almost the same: 1.9 and 1.8 %/°C for 1.600 and 1.610 μm. That is, the glucose dependence across the whole temperature range remains constant. This implies that temperature correction is available.

  13. Accuracy of Continuous Glucose Monitoring Measurements in Normo-Glycemic Individuals

    DEFF Research Database (Denmark)

    Akintola, Abimbola A; Noordam, Raymond; Jansen, Steffy W

    2015-01-01

    a 24-hour period. Validity of CGM-derived individual glucose measurements, calculated measures of glycemia over daytime (09:00h-23:00h) and nighttime (23:00h-09:00h), and calculated measures of glycemic variability (e.g. 24h standard deviation [SD]) were assessed by Pearson correlation coefficients......, mean absolute relative difference (MARD) and paired t-tests. RESULTS: The median correlation coefficient between CGM and venous glucose measurements per participant was 0.68 (interquartile range: 0.40-0.78), and the MARD was 17.6% (SD = 17%). Compared with venous sampling, the calculated measure...

  14. Atypical blood glucose response to continuous and interval exercise in a person with type 1 diabetes: a case report.

    Science.gov (United States)

    Moser, Othmar; Tschakert, Gerhard; Mueller, Alexander; Groeschl, Werner; Pieber, Thomas R; Koehler, Gerd; Eckstein, Max L; Bracken, Richard M; Hofmann, Peter

    2017-06-30

    Therapy must be adapted for people with type 1 diabetes to avoid exercise-induced hypoglycemia caused by increased exercise-related glucose uptake into muscles. Therefore, to avoid hypoglycemia, the preexercise short-acting insulin dose must be reduced for safety reasons. We report a case of a man with long-lasting type 1 diabetes in whom no blood glucose decrease during different types of exercise with varying exercise intensities and modes was found, despite physiological hormone responses. A Caucasian man diagnosed with type 1 diabetes for 24 years performed three different continuous high-intensity interval cycle ergometer exercises as part of a clinical trial (ClinicalTrials.gov identifier NCT02075567). Intensities for both modes of exercises were set at 5% below and 5% above the first lactate turn point and 5% below the second lactate turn point. Short-acting insulin doses were reduced by 25%, 50%, and 75%, respectively. Measurements taken included blood glucose, blood lactate, gas exchange, heart rate, adrenaline, noradrenaline, cortisol, glucagon, and insulin-like growth factor-1. Unexpectedly, no significant blood glucose decreases were observed during all exercise sessions (start versus end, 12.97 ± 2.12 versus 12.61 ± 2.66 mmol L -1 , p = 0.259). All hormones showed the expected response, dependent on the different intensities and modes of exercises. People with type 1 diabetes typically experience a decrease in blood glucose levels, particularly during low- and moderate-intensity exercises. In our patient, we clearly found no decline in blood glucose, despite a normal hormone response and no history of any insulin insensitivity. This report indicates that there might be patients for whom the recommended preexercise therapy adaptation to avoid exercise-induced hypoglycemia needs to be questioned because this could increase the risk of severe hyperglycemia and ketosis.

  15. Continuous glucose profiles in obese and normal-weight pregnant women on a controlled diet: metabolic determinants of fetal growth.

    Science.gov (United States)

    Harmon, Kristin A; Gerard, Lori; Jensen, Dalan R; Kealey, Elizabeth H; Hernandez, Teri L; Reece, Melanie S; Barbour, Linda A; Bessesen, Daniel H

    2011-10-01

    We sought to define 24-h glycemia in normal-weight and obese pregnant women using continuous glucose monitoring (CGM) while they consumed a habitual and controlled diet both early and late in pregnancy. Glycemia was prospectively measured in early (15.7 ± 2.0 weeks' gestation) and late (27.7 ± 1.7 weeks' gestation) pregnancy in normal-weight (n = 22) and obese (n = 16) pregnant women on an ad libitum and controlled diet. Fasting glucose, triglycerides (early pregnancy only), nonesterified fatty acids (FFAs), and insulin also were measured. The 24-h glucose area under the curve was higher in obese women than in normal-weight women both early and late in pregnancy despite controlled diets. Nearly all fasting and postprandial glycemic parameters were higher in the obese women later in pregnancy, as were fasting insulin, triglycerides, and FFAs. Infants born to obese mothers had greater adiposity. Maternal BMI (r = 0.54, P = 0.01), late average daytime glucose (r = 0.48, P fasting insulin (r = 0.49, P fasting triglycerides (r = 0.67, P fasting FFAs (r = 0.54, P obese women without diabetes have higher daytime and nocturnal glucose profiles than normal-weight women despite a controlled diet both early and late in gestation. Body fat in infants, not birth weight, was related to maternal BMI, glucose, insulin, and FFAs, but triglycerides were the strongest predictor. These metabolic findings may explain higher rates of infant macrosomia in obese women, which might be targeted in trials to prevent excess fetal growth.

  16. A low perfusion rate microreactor for continuous monitoring of enzyme characteristics : application to glucose oxidase

    NARCIS (Netherlands)

    Posthuma-Trumpie, G. A.; Venema, K.; van Berkel, W. J. H.; Korf, J.

    This report describes a versatile and robust microreactor for bioactive proteins physically immobilized on a polyether sulfone filter. The potential of the reactor is illustrated with glucose oxidase immobilized on a filter with a cut-off value of 30 kDa. A flow-injection system was used to deliver

  17. Comparison of Three Nonlinear Filters for Fault Detection in Continuous Glucose Monitors

    DEFF Research Database (Denmark)

    Mahmoudi, Zeinab; Wendt, Sabrina Lyngbye; Boiroux, Dimitri

    2016-01-01

    model of the glucose-insulin dynamics in people with type 1 diabetes. Drift is modelled by a Gaussian random walk and is detected based on the statistical tests of the 90-min prediction residuals of the filters. The unscented Kalman filter had the highest average F score of 85.9%, and the smallest...

  18. Precursors of Reading Skill From Infancy to First Grade in Finnish: Continuity and Change in a Highly Inflected Language

    NARCIS (Netherlands)

    Silvén, M.; Poskiparta, E.H.; Niemi, P.; Voeten, M.J.M.

    2007-01-01

    The course of language acquisition from infancy to public primary school was followed in a sample of 56 Finnish children to examine precursors to reading at first grade. Structural equation modeling of continuity suggested effects from growth in early vocabulary to mastery of inflectional forms at

  19. Continuous subcutaneous infusion of glucagon-like peptide 1 lowers plasma glucose and reduces appetite in type 2 diabetic patients

    DEFF Research Database (Denmark)

    Toft-Nielsen, M B; Madsbad, Sten; Holst, J J

    1999-01-01

    OBJECTIVE: The gut hormone glucagon-like peptide 1 (GLP-1) has insulinotropic and anorectic effects during intravenous infusion and has been proposed as a new treatment for type 2 diabetes and obesity. The effect of a single subcutaneous injection is brief because of rapid degradation. We therefo....... CONCLUSIONS: We conclude that 48-h continuous subcutaneous infusion of GLP-1 in type 2 diabetic patients 1) lowers fasting as well as meal-related plasma glucose, 2) reduces appetite, 3) has no gastrointestinal side effects, and 4) has no negative effect on blood pressure.......OBJECTIVE: The gut hormone glucagon-like peptide 1 (GLP-1) has insulinotropic and anorectic effects during intravenous infusion and has been proposed as a new treatment for type 2 diabetes and obesity. The effect of a single subcutaneous injection is brief because of rapid degradation. We therefore......, previously shown to lower blood glucose effectively in type 2 diabetic patients. Fasting plasma glucose (day 2) decreased from 14.1 +/- 0.9 (saline) to 12.2 +/- 0.7 mmol/l (GLP-1), P = 0.009, and 24-h mean plasma glucose decreased from 15.4 +/- 1.0 to 13.0 +/- 1.0 mmol/l, P = 0.0009. Fasting and total area...

  20. Smart telemedicine support for continuous glucose monitoring: the embryo of a future global agent for diabetes care.

    Science.gov (United States)

    Rigla, Mercedes

    2011-01-01

    Although current systems for continuous glucose monitoring (CGM) are the result of progressive technological improvement, and although a beneficial effect on glucose control has been demonstrated, few patients are using them. Something similar has happened to telemedicine (TM); in spite of the long-term experience, which began in the early 1980s, no TM system has been widely adopted, and presential visits are still almost the only way diabetologists and patients communicate. The hypothesis developed in this article is that neither CGM nor TM will ever be routinely implemented separately, and their consideration as essential elements for standard diabetes care will one day come from their integration as parts of a telemedical monitoring platform. This platform, which should include artificial intelligence for giving decision support to patients and physicians, will represent the core of a more complex global agent for diabetes care, which will provide control algorithms and risk analysis among other essential functions. © 2010 Diabetes Technology Society.

  1. Association between the extent of urinary albumin excretion and glycaemic variability indices measured by continuous glucose monitoring.

    Science.gov (United States)

    Jin, S-M; Kim, T-H; Oh, S; Baek, J; Joung, J Y; Park, S-M; Cho, Y Y; Sohn, S Y; Hur, K Y; Lee, M-S; Lee, M-K; Kim, J H

    2015-02-01

    The contribution of glycaemic variability to the microvascular complication of diabetes has not been established. We examined whether there is an independent association between indices of glycaemic variability in continuous glucose monitoring and extent of albuminuria. A total of 173 patients with Type 2 diabetes (without insulin therapy, n = 96; with insulin therapy, n = 77) who had unexplained large fluctuations in blood glucose values underwent three-day continuous glucose monitoring. We used a multinomial logistic regression model to determine whether the indices of glycaemic variability independently affected the odds of having a spot urine albumin/creatinine ratio of 30-299 mg/g and ≥ 300 mg/g. Higher standard deviation (P = 0.002), mean of daily differences (P = 0.023) and mean amplitude of glycaemic excursion (P = 0.043) significantly increased the odds of having a urine albumin/creatinine ratio of ≥ 300 mg/g. In multivariable analysis, only higher standard deviation, but not mean amplitude of glycaemic excursion and mean of daily differences, independently increased the odds of having a urine albumin/creatinine ratio of ≥ 300 mg/g (P = 0.025). Coefficient of variation (sd/mean) was not associated with the odds of having a urine albumin/creatinine ratio of 30-299 or ≥ 300 mg/g. The independent association between standard deviation and the extent of albuminuria was lost when the measures were normalized by mean glucose level. At least in terms of relative measures of glycaemic variability, we failed to demonstrate an independent association between glycaemic variability and albuminuria extent in patients with inadequately controlled Type 2 diabetes. © 2014 The Authors. Diabetic Medicine © 2014 Diabetes UK.

  2. CONTINUOUS GLUCOSE MONITORING: A CONSENSUS CONFERENCE OF THE AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS AND AMERICAN COLLEGE OF ENDOCRINOLOGY.

    Science.gov (United States)

    Fonseca, Vivian A; Grunberger, George; Anhalt, Henry; Bailey, Timothy S; Blevins, Thomas; Garg, Satish K; Handelsman, Yehuda; Hirsch, Irl B; Orzeck, Eric A; Roberts, Victor Lawrence; Tamborlane, William

    2016-08-01

    Barriers to continuous glucose monitoring (CGM) use continue to hamper adoption of this valuable technology for the management of diabetes. The American Association of Clinical Endocrinologists and the American College of Endocrinology convened a public consensus conference February 20, 2016, to review available CGM data and propose strategies for expanding CGM access. Conference participants agreed that evidence supports the benefits of CGM in type 1 diabetes and that these benefits are likely to apply whenever intensive insulin therapy is used, regardless of diabetes type. CGM is likely to reduce healthcare resource utilization for acute and chronic complications, although real-world analyses are needed to confirm potential cost savings and quality of life improvements. Ongoing technological advances have improved CGM accuracy and usability, but more innovations in human factors, data delivery, reporting, and interpretation are needed to foster expanded use. The development of a standardized data report using similar metrics across all devices would facilitate clinician and patient understanding and utilization of CGM. Expanded CGM coverage by government and private payers is an urgent need. CGM improves glycemic control, reduces hypoglycemia, and may reduce overall costs of diabetes management. Expanding CGM coverage and utilization is likely to improve the health outcomes of people with diabetes. A1C = glycated hemoglobin AACE = American Association of Clinical Endocrinologists ACE = American College of Endocrinology ASPIRE = Automation to Simulate Pancreatic Insulin Response CGM = continuous glucose monitoring HRQOL = health-related quality of life ICER = incremental cost-effectiveness ratio JDRF = Juvenile Diabetes Research Foundation MARD = mean absolute relative difference MDI = multiple daily injections QALY = quality-adjusted life years RCT = randomized, controlled trial SAP = sensor-augmented pump SMBG = self-monitoring of blood glucose STAR = Sensor

  3. Impact of continuous glucose monitoring on quality of life, treatment satisfaction, and use of medical care resources

    DEFF Research Database (Denmark)

    Hommel, E; Olsen, B; Battelino, T

    2014-01-01

    To investigate the impact of continuous glucose monitoring (CGM) on health-related quality of life (HRQOL), treatment satisfaction (TS) medical resource use, and indirect costs in the SWITCH study. SWITCH was a multicentre, randomized, crossover study. Patients with type 1 diabetes (n = 153) using...... longer during the sensor-On arm. Regarding indirect costs, children with >70 % sensor usage missed fewer school days, compared with the sensor-Off arm (P = 0.0046) but there was no significant difference in the adults days of work off. The addition of CGM to CSII resulted in better metabolic control...

  4. Clinical value of Flash glucose monitoring in patients with type 1 diabetes treated with continuous subcutaneous insulin infusion.

    Science.gov (United States)

    Moreno-Fernandez, Jesus; Pazos-Couselo, Marcos; González-Rodriguez, Maria; Rozas, Pedro; Delgado, Manuel; Aguirre, Miguel; Garcia-Lopez, Jose Manuel

    2018-06-12

    To analyze the clinical impact of the Flash glucose monitoring system in patients with type 1 diabetes mellitus (T1DM) treated with continuous subcutaneous insulin infusion (CSII). A 24-week retrospective cohort study in CSII-treated T1DM patients exposed (1:1) to the Flash glucose monitoring system vs. self-monitoring of capillary blood glucose (SMBG). The primary outcome was the difference in hemoglobin A1c (HbA1c) levels between both groups at the end of the study. Thirty-six patients with a mean age of 38.2 years (range 22-55) and a mean T1DM duration of 20.9±7.8 years, treated with CSII for 7.1±5.4 years, were enrolled into the study. At the end of the study, mean HbA1c levels improved in patients in the Flash group (7.1±0.7 vs. 7.8±1.0, p=0.04). Only the Flash group showed a significant decrease in HbA1c levels of -0.4% (95% CI, -0.6, -0.2; p=0.004) during follow-up. Flash patients captured 93.9% of data through 17.8±9.9 scans daily. In fact, the Flash cohort showed a three-fold increase in daily self-monitoring of glucose, while daily frequency of SMBG decreased during the study (-1.8 tests/24h (95% CI -3, -0.7; p=0.01). No safety issues related to Flash use were recorded. The Flash glucose monitoring system is a novel approach to improve blood glucose control in CSII-treated T1DM patients. Randomized controlled trials are needed to assess the effectiveness of this system in CSII-treated T1DM patients. Copyright © 2018 SEEN y SED. Publicado por Elsevier España, S.L.U. All rights reserved.

  5. Usefulness of continuous glucose monitoring for the diagnosis of hypoglycemia after a gastric bypass in a patient previously treated for type 2 diabetes.

    Science.gov (United States)

    Hanaire, Hélène; Dubet, Audrey; Chauveau, Marie-Emilie; Anduze, Yves; Fernandes, Martine; Melki, Vincent; Ritz, Patrick

    2010-01-01

    Hypoglycemia is rare after a gastric bypass and can be taken for a dumping syndrome. There is no report in the literature of the contribution of continuous glucose monitoring to the diagnosis of hypoglycemia in these circumstances. The present case report shows that continuous glucose monitoring can be a useful tool for the diagnosis and the management of such episodes. Continuous glucose monitoring revealed hypoglycemic episodes in free living circumstances that were not present during 72-h fasting. These episodes followed wide hyperglycemic swings. No such episode resumed over 8 months after specific dietary advices and treatment by 50 mg TID of acarbose. Because hypoglycemia can be difficult to diagnose from dumping syndrome, continuous glucose monitoring is a very useful tool revealing the episodes in free living circumstances and can be used to monitor the treatment success.

  6. Self-Monitoring Using Continuous Glucose Monitors with Real-Time Feedback Improves Exercise Adherence in Individuals with Impaired Blood Glucose: A Pilot Study.

    Science.gov (United States)

    Bailey, Kaitlyn J; Little, Jonathan P; Jung, Mary E

    2016-03-01

    Exercise helps individuals with prediabetes or type 2 diabetes (T2D) manage their blood glucose (BG); however, exercise adherence in this population is dismal. In this pilot study we tested the efficacy of a self-monitoring group-based intervention using continuous glucose monitors (CGMs) at increasing exercise adherence in individuals with impaired BG. Thirteen participants with prediabetes or T2D were randomized to an 8-week standard care exercise program (CON condition) (n = 7) or self-monitoring exercise intervention (SM condition) (n = 6). Participants in the SM condition were taught how to self-monitor their exercise and BG, to goal set, and to use CGM to observe how exercise influences BG. We hypothesized that compared with the CON condition, using a real-time CGM would facilitate self-monitoring behavior, resulting in increased exercise adherence. Repeated-measures analysis of variance revealed significant Condition × Time interactions for self-monitoring (P goal setting (P = 0.01), and self-efficacy to self-monitor (P = 0.01), such that the SM condition showed greater increases in these outcomes immediately after the program and at the 1-month follow-up compared with the CON condition. The SM condition had higher program attendance rates (P = 0.03), and a greater proportion of participants reregistered for additional exercise programs (P = 0.048) compared with the CON condition. Participants in both conditions experienced improvements in health-related quality of life, waist circumference, and fitness (P values exercise behavior in individuals living with prediabetes or T2D.

  7. Association of glycaemic variability evaluated by continuous glucose monitoring with diabetic peripheral neuropathy in type 2 diabetic patients.

    Science.gov (United States)

    Hu, Yu-Ming; Zhao, Li-Hua; Zhang, Xiu-Lin; Cai, Hong-Li; Huang, Hai-Yan; Xu, Feng; Chen, Tong; Wang, Xue-Qin; Guo, Ai-Song; Li, Jian-An; Su, Jian-Bin

    2018-05-01

    Diabetic peripheral neuropathy (DPN), a common microvascular complication of diabetes, is linked to glycaemic derangements. Glycaemic variability, as a pattern of glycaemic derangements, is a key risk factor for diabetic complications. We investigated the association of glycaemic variability with DPN in a large-scale sample of type 2 diabetic patients. In this cross-sectional study, we enrolled 982 type 2 diabetic patients who were screened for DPN and monitored by a continuous glucose monitoring (CGM) system between February 2011 and January 2017. Multiple glycaemic variability parameters, including the mean amplitude of glycaemic excursions (MAGE), mean of daily differences (MODD), standard deviation of glucose (SD), and 24-h mean glucose (24-h MG), were calculated from glucose profiles obtained from CGM. Other possible risks for DPN were also examined. Of the recruited type 2 diabetic patients, 20.1% (n = 197) presented with DPN, and these patients also had a higher MAGE, MODD, SD, and 24-h MG than patients without DPN (p diabetic duration, HOMA-IR, and hemoglobin A1c (HbA1c) were found to be independent contributors to DPN, and the corresponding odds ratios (95% confidence interval) were 4.57 (3.48-6.01), 1.10 (1.03-1.17), 1.24 (1.09-1.41), and 1.33 (1.15-1.53), respectively. Receiver operating characteristic analysis indicated that the optimal MAGE cutoff value for predicting DPN was 4.60 mmol/L; the corresponding sensitivity was 64.47%, and the specificity was 75.54%. In addition to conventional risks including diabetic duration, HOMA-IR and HbA1c, increased glycaemic variability assessed by MAGE is a significant independent contributor to DPN in type 2 diabetic patients.

  8. Development of Chemically Amplified Optical Sensors for Continuous Blood Glucose Monitoring Final Report CRADA No. TSB-1162-95

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Stephen M. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Univ. of California, Livermore, CA (United States); Mastrototaro, John J. [Minimed Technologies, Inc., Sylmar, CA (United States)

    2018-01-22

    Diabetes is a chronic disease that affects 14 million people in the U.S. and more than 110 million people worldwide. Each year in this country 27,000 diabetic patients become blind, 15,000 have kidney failure, and over 54,000 have peripheral limb amputations. In 1992, total healthcare costs in the U.S. for diabetes were more than $105 billion, approximately 15% of our healthcare budget. Conventional therapy for the most severe form of diabetes, insulin-dependent diabetes mellitus (IDDM) or Type I diabetes, is to administer one or two injections per day of various forms of insulin while monitoring blood glucose levels twice or three times daily with commercial glucometers that require blood samples. Near normal blood sugar levels (glycemic control) is difficult to achieve with conventional therapy. In the fall of 1993, the results of the 10-year $165 million Diabetes Control and Complications Trial (DCCT) were published which showed that intensive insulin management would lead to dramatically fewer cases of retinopathy (which leads to blindness), nephropathy (which leads to kidney failure), and neuropathy (which can lead to limb amputations) [New England Journal of Medicine, Vo1239, No.14 977-986 (1993)]. If existing commercial insulin pumps could be combined with a continuous glucose sensor, a more physiological and fine-tuned therapy could be provided - in effect, an artificial biomechanical pancreas would be available. Existing research suggested that such a development would dramatically improve glucose control, thus greatly reducing morbidity and mortality from this disease. MiniMed Technologies in Sylmar, CA, identified a number of optically based sensor strategies as well as candidate chemical reactions that could be used to implement a minimally invasive opto-chemical glucose sensor. LLNL evaluated these sensor strategies and chemical reactions. These evaluations were the first steps leading to development of a sensor of considerable importance that could

  9. Time-Series Analysis of Continuously Monitored Blood Glucose: The Impacts of Geographic and Daily Lifestyle Factors

    Directory of Open Access Journals (Sweden)

    Sean T. Doherty

    2015-01-01

    Full Text Available Type 2 diabetes is known to be associated with environmental, behavioral, and lifestyle factors. However, the actual impacts of these factors on blood glucose (BG variation throughout the day have remained relatively unexplored. Continuous blood glucose monitors combined with human activity tracking technologies afford new opportunities for exploration in a naturalistic setting. Data from a study of 40 patients with diabetes is utilized in this paper, including continuously monitored BG, food/medicine intake, and patient activity/location tracked using global positioning systems over a 4-day period. Standard linear regression and more disaggregated time-series analysis using autoregressive integrated moving average (ARIMA are used to explore patient BG variation throughout the day and over space. The ARIMA models revealed a wide variety of BG correlating factors related to specific activity types, locations (especially those far from home, and travel modes, although the impacts were highly personal. Traditional variables related to food intake and medications were less often significant. Overall, the time-series analysis revealed considerable patient-by-patient variation in the effects of geographic and daily lifestyle factors. We would suggest that maps of BG spatial variation or an interactive messaging system could provide new tools to engage patients and highlight potential risk factors.

  10. Accuracy of Continuous Glucose Monitoring (CGM during Continuous and High-Intensity Interval Exercise in Patients with Type 1 Diabetes Mellitus

    Directory of Open Access Journals (Sweden)

    Othmar Moser

    2016-08-01

    Full Text Available Continuous exercise (CON and high-intensity interval exercise (HIIE can be safely performed with type 1 diabetes mellitus (T1DM. Additionally, continuous glucose monitoring (CGM systems may serve as a tool to reduce the risk of exercise-induced hypoglycemia. It is unclear if CGM is accurate during CON and HIIE at different mean workloads. Seven T1DM patients performed CON and HIIE at 5% below (L and above (M the first lactate turn point (LTP1, and 5% below the second lactate turn point (LTP2 (H on a cycle ergometer. Glucose was measured via CGM and in capillary blood (BG. Differences were found in comparison of CGM vs. BG in three out of the six tests (p < 0.05. In CON, bias and levels of agreement for L, M, and H were found at: 0.85 (−3.44, 5.15 mmol·L−1, −0.45 (−3.95, 3.05 mmol·L−1, −0.31 (−8.83, 8.20 mmol·L−1 and at 1.17 (−2.06, 4.40 mmol·L−1, 0.11 (−5.79, 6.01 mmol·L−1, 1.48 (−2.60, 5.57 mmol·L−1 in HIIE for the same intensities. Clinically-acceptable results (except for CON H were found. CGM estimated BG to be clinically acceptable, except for CON H. Additionally, using CGM may increase avoidance of exercise-induced hypoglycemia, but usual BG control should be performed during intense exercise.

  11. Glucose Sensing

    CERN Document Server

    Geddes, Chris D

    2006-01-01

    Topics in Fluorescence Spectroscopy, Glucose Sensing is the eleventh volume in the popular series Topics in Fluorescence Spectroscopy, edited by Drs. Chris D. Geddes and Joseph R. Lakowicz. This volume incorporates authoritative analytical fluorescence-based glucose sensing reviews specialized enough to be attractive to professional researchers, yet also appealing to the wider audience of scientists in related disciplines of fluorescence. Glucose Sensing is an essential reference for any lab working in the analytical fluorescence glucose sensing field. All academics, bench scientists, and industry professionals wishing to take advantage of the latest and greatest in the continuously emerging field of glucose sensing, and diabetes care & management, will find this volume an invaluable resource. Topics in Fluorescence Spectroscopy Volume 11, Glucose Sensing Chapters include: Implantable Sensors for Interstitial Fluid Smart Tattoo Glucose Sensors Optical Enzyme-based Glucose Biosensors Plasmonic Glucose Sens...

  12. IDegLira Improves Both Fasting and Postprandial Glucose Control as Demonstrated Using Continuous Glucose Monitoring and a Standardized Meal Test.

    Science.gov (United States)

    Holst, Jens J; Buse, John B; Rodbard, Helena W; Linjawi, Sultan; Woo, Vincent C; Boesgaard, Trine Welløv; Kvist, Kajsa; Gough, Stephen C

    2015-10-06

    IDegLira is a novel, fixed-ratio combination of the long-acting basal insulin, insulin degludec, and the long-acting glucagon-like peptide-1 analog liraglutide. We studied the effect of IDegLira versus its components on postprandial glucose (PPG) in type 2 diabetes. In this substudy, 260 (15.6%) of the original 1663 patients with inadequate glycemic control participating in a 26-week, open-label trial (DUAL I) were randomized 2:1:1 to once-daily IDegLira, insulin degludec or liraglutide. Continuous glucose monitoring (CGM) for 72 hours and a meal test were performed. At week 26, IDegLira produced a significantly greater decrease from baseline in mean PPG increment (normalized iAUC0-4h) than insulin degludec (estimated treatment difference [ETD] -12.79 mg/dl [95% CI: -21.08; -4.68], P = .0023) and a similar magnitude of decrease as liraglutide (ETD -1.62 mg/dl [95% CI: -10.09; 6.67], P = .70). CGM indicated a greater reduction in change from baseline in PPG increment (iAUC0-4h) for IDegLira versus insulin degludec over all 3 main meals (ETD -6.13 mg/dl [95% CI: -10.27, -1.98], P = .0047) and similar reductions versus liraglutide (ETD -1.80 mg/dl [95% CI: -2.52, 5.95], P = .4122). Insulin secretion ratio and static index were greater for IDegLira versus insulin degludec (P = .048 and P = .006, respectively) and similar to liraglutide (P = .45 and P = .895, respectively). Once-daily IDegLira provides significantly better PPG control following a mixed meal test than insulin degludec. The improvement is at least partially explained by higher endogenous insulin secretion and improved beta cell function with IDegLira. The benefits of liraglutide on PPG control are maintained across all main meals in the combination. © 2015 Diabetes Technology Society.

  13. [Usefulness of continuous glucose monitoring system (CGMS) in monitoring glycaemic profile in small children with diabetes type 1].

    Science.gov (United States)

    Głowińska-Olszewska, Barbara; Urban, Mirosława; Peczyńska, Jadwiga; Florys, Bozena; Kowalewski, Marek

    2005-01-01

    Improved methods of diabetes therapy result in a near normoglycaemic state in many patients. This leads however unfortunately to more frequent hypoglycaemic incidents. Particularly small children, whose nervous system is not fully mature, are at high risk of central nervous system damage in case of hypoglycaemia. A new method of detail monitoring of glycaemia provides CGMS system. The aim of the study was to compare the glycaemic profile, with high attention to hypoglycaemia in groups of young and older children with diabetes type 1, using CGMS and routine glucose meter. We studied 32 children with diabetes type 1. Children were divided into groups: group I--small children, n=17 (10 years of age), mean age--12 years, with disease duration--3 years, with HbA1c level--7,21%. Continuous glucose monitoring system (CGMS), by MiniMed, was applied in outpatient or hospital conditions, after short training of patient and parents; together with routine glucose meter measurements, 4-8 times/24 hours. In 9 patients from small children group CGMS was repeated after 2 months. Hypoglycaemic incidents detected with CGMS were similar in both groups: 4,6 in I group vs. 4,2 in II group (ns). Hypoglycaemic incidents found with meter were lower in I group--1,6 vs. 2,3 in II group (ns). Mean hypoglycaemic time/24 hour was longer in small children group: 101 min vs. 74 min in group II (p<00,05). In I group we found higher number of hypoglycaemic incidents during the night compared to group II--1,7 vs. 0,8 (p<00,05) and longer duration of night hypoglycaemia: in I group--56 min vs. 32 min in group II (p<00,05). Repeated CGMS study in 9 children from I group revealed decreased mean time of hypoglycaemia/24 hours from 134 min/24 h to 90 min/24 h (p<00,05) and decreased time of night hypoglycaemia from 65 min to 40 min (p<00,05), with a comparable number of hypoglycaemic incidents. Hypoglycaemic incidents found with routine meter measurements in small children were 1,6 vs. 4,6 hypoglycaemia

  14. Effectiveness of Continuous Glucose Monitoring for Managing Type-1 Diabetic Patients and Barrier to Its Use: A Quasi Interventional Trial

    Directory of Open Access Journals (Sweden)

    Hassan M. Al-Musa

    2018-04-01

    Full Text Available Background: Type-1 diabetes is one of the largest endocrine and metabolic health issues among children and young adults. Diabetes mellitus is associated with many long-term complications. Aim and Objectives: To compare outcomes in groups monitored either by real time continuous glucose monitoring or by Self Monitoring of Blood Glucose (SMBG; 3-4 blood glucose measurements per day. Also we studied barrier for the use of CMG. Material and Methods: It is a prospective quasi experimental controlled trial at diabetic center in Abha, KSA. Out of 307 patients registered, 60 T1DM patients agreed to participate; out of them 30 patients were enrolled in intervention cohort, they used CGM sensor continuously while 30 patients were in the control group they used SMBG. All were followed for 6 months; HbA1c was measured at 3 and 6 months. Barrier to use of sensor was evaluated with a questionnaire. Results: At baseline no significant difference was observed in the average HbA1c between the groups (10.57 % vs 10.73 %. HbA1c reduction compared to baseline levels in the intervention cohort was 2.15% and 2.36% at 3 and 6 months. In control group, HbA1c reduced to 1.07% and 1.22% at 3 and 6 months showing significant difference (p=0.002 and p=0.001 at 3 and 6 months. Younger patients age <20 years had significantly better reduction of HbA1c (2.28% vs 1.27%, p=0.015 and 2.47% vs 1.98%, p=0.004 at 3 and 6 months. The hypoglycemic events were statistically reduced in the intervention group (p<0.001 and also the ketoacidosis and hospital admissions (20.0% vs, 3.3%, p<0.001. Conclusion: We found that the use of CGM sensor was associated with significant HbA1c reductions and improved glycaemic control.

  15. Personalized State-space Modeling of Glucose Dynamics for Type 1 Diabetes Using Continuously Monitored Glucose, Insulin Dose, and Meal Intake: An Extended Kalman Filter Approach

    OpenAIRE

    Wang, Qian; Molenaar, Peter; Harsh, Saurabh; Freeman, Kenneth; Xie, Jinyu; Gold, Carol; Rovine, Mike; Ulbrecht, Jan

    2014-01-01

    An essential component of any artificial pancreas is on the prediction of blood glucose levels as a function of exogenous and endogenous perturbations such as insulin dose, meal intake, and physical activity and emotional tone under natural living conditions. In this article, we present a new data-driven state-space dynamic model with time-varying coefficients that are used to explicitly quantify the time-varying patient-specific effects of insulin dose and meal intake on blood glucose fluctu...

  16. Continuous subcutaneous insulin infusion (CSII) therapy at Derby Teaching Hospitals: sustained benefits in glucose control.

    Science.gov (United States)

    Anyanwagu, U; Olaoye, H; Jennings, P; Ashton-Cleary, S; Sugunendran, S; Hughes, D; Idris, I; Wilmot, E G

    2017-08-01

    In the short term, continuous subcutaneous insulin infusion (CSII) has been associated with improved glycaemic control, reduced hypoglycaemia and improved quality of life (QOL). However, limited data are available on its long-term benefits, particularly in the UK. We aimed to assess the impact of CSII on longer term outcomes. Patient-level data were obtained for CSII users at Derby Teaching Hospitals, UK. Patient confidence and satisfaction questionnaires using the Likert scale were used to assess confidence in self-management. Comparative statistics were conducted using Pearson's chi-square and Student's t-tests. Some 258 CSII users were identified (60.1% female, mean age 43.9 ± 13.4 years). Overall, there was significant decrease in HbA 1c from 78 mmol/mol (9.3 ± 2.0%) at baseline, to 69 mmol/mol (8.5 ± 1.3%) at 6 months [mean difference (md): -0.64; 95% confidence interval (95% CI): -0.91 to -0.37; P quality of care received in the insulin pump service. CSII therapy led to a sustained long-term improvement in glycaemic control in addition to a reduction in self-reported hypoglycaemia. © 2017 Diabetes UK.

  17. Heterogeneous performances of conceptual dis/continuity: a dialectic reading of Brown and Kloser's article

    Science.gov (United States)

    Hwang, Sungwon; Kim, Mijung

    2009-12-01

    We review Brown and Kloser's article, "Conceptual continuity and the science of baseball: using informal science literacy to promote students science learning" from a Vygotskian cultural-historical and dialectic perspective. Brown and Kloser interpret interview data with student baseball players and claim that students' conceptual understanding articulated in vernacular genres involves continuities (similarities) with the canonical scientific explanations. In this commentary, we suggest that the authors' approach presupposes the dichotomy of the formal and the informal, which brings the authors' attention to continuity into the separation of cognition from language. We propose a Vygotskian approach that points out the problem of theorizing cognition (conceptual understanding) by depending on specific forms of representation (e.g., scientific terms). As alternative, we envision a Vygotskian cultural-historical approach to language, which considers different, irreducible modes of communication as an integrated whole and therefore allows theorizing cognition without dichotomizing it from the concrete ways by which human being communicates. We provide an exemplary analysis of a lecture talk in a university physics classroom and exemplify dialectic theories that explain the development of conceptual understanding. We discuss that this Vygotskian dialectic approach shows that people communicate scientific concepts through hybridization, which does not reproduce a genre self-identically; the continuity of conceptual understanding involves dis/continuity.

  18. Efficacy of Additional Canagliflozin Administration to Type 2 Diabetes Patients Receiving Insulin Therapy: Examination of Diurnal Glycemic Patterns Using Continuous Glucose Monitoring (CGM).

    Science.gov (United States)

    Matsumura, Mihoko; Nakatani, Yuki; Tanka, Seiichi; Aoki, Chie; Sagara, Masaaki; Yanagi, Kazunori; Suzuki, Kunihiro; Aso, Yoshimasa

    2017-08-01

    The efficacy of administering a sodium-glucose cotransporter 2 inhibitor during insulin therapy has not been established. In this study, we examined its effects based on diurnal glycemic patterns using continuous glucose monitoring (CGM). The subjects were 15 patients who had received insulin therapy for 1 year or more. A CGM device was attached to all subjects for 1 week. The administration of canagliflozin at 100 mg was started 4 days after attachment. The mean glucose concentrations, standard deviation (SD), mean amplitude of glycemic excursions (MAGE), mean of daily difference of blood glucose (MODD), and area under the curve (AUC) (≥180, glucose concentrations decreased from 161.1 to 139.1 mg/dL (P AUC of ≥180, i.e., the total area of blood glucose levels at or above 180 on the blood glucose curve of CGM, decreased from 339.1 to 113.6 mg/dL (P AUC of blood glucose levels below 70 on the blood glucose curve of CGM, slightly decreased from 1.6 to 0.3 mg/dL (P = 0.08). The total number of basal insulin units decreased from 128 to 76, and that of bolus insulin decreased from 266 to 154; the dose of insulin could be markedly decreased. In addition, the mean 8-OHdG level decreased from 11.4 to 10.8 ng/mg Cre (P blood glucose changes in type 2 diabetes using insulin. In addition, the results suggest its antioxidant actions. University Hospital Medical Information Network (UMIN no. 000019429).

  19. Personalized State-space Modeling of Glucose Dynamics for Type 1 Diabetes Using Continuously Monitored Glucose, Insulin Dose, and Meal Intake

    Science.gov (United States)

    Molenaar, Peter; Harsh, Saurabh; Freeman, Kenneth; Xie, Jinyu; Gold, Carol; Rovine, Mike; Ulbrecht, Jan

    2014-01-01

    An essential component of any artificial pancreas is on the prediction of blood glucose levels as a function of exogenous and endogenous perturbations such as insulin dose, meal intake, and physical activity and emotional tone under natural living conditions. In this article, we present a new data-driven state-space dynamic model with time-varying coefficients that are used to explicitly quantify the time-varying patient-specific effects of insulin dose and meal intake on blood glucose fluctuations. Using the 3-variate time series of glucose level, insulin dose, and meal intake of an individual type 1 diabetic subject, we apply an extended Kalman filter (EKF) to estimate time-varying coefficients of the patient-specific state-space model. We evaluate our empirical modeling using (1) the FDA-approved UVa/Padova simulator with 30 virtual patients and (2) clinical data of 5 type 1 diabetic patients under natural living conditions. Compared to a forgetting-factor-based recursive ARX model of the same order, the EKF model predictions have higher fit, and significantly better temporal gain and J index and thus are superior in early detection of upward and downward trends in glucose. The EKF based state-space model developed in this article is particularly suitable for model-based state-feedback control designs since the Kalman filter estimates the state variable of the glucose dynamics based on the measured glucose time series. In addition, since the model parameters are estimated in real time, this model is also suitable for adaptive control. PMID:24876585

  20. Personalized State-space Modeling of Glucose Dynamics for Type 1 Diabetes Using Continuously Monitored Glucose, Insulin Dose, and Meal Intake: An Extended Kalman Filter Approach.

    Science.gov (United States)

    Wang, Qian; Molenaar, Peter; Harsh, Saurabh; Freeman, Kenneth; Xie, Jinyu; Gold, Carol; Rovine, Mike; Ulbrecht, Jan

    2014-03-01

    An essential component of any artificial pancreas is on the prediction of blood glucose levels as a function of exogenous and endogenous perturbations such as insulin dose, meal intake, and physical activity and emotional tone under natural living conditions. In this article, we present a new data-driven state-space dynamic model with time-varying coefficients that are used to explicitly quantify the time-varying patient-specific effects of insulin dose and meal intake on blood glucose fluctuations. Using the 3-variate time series of glucose level, insulin dose, and meal intake of an individual type 1 diabetic subject, we apply an extended Kalman filter (EKF) to estimate time-varying coefficients of the patient-specific state-space model. We evaluate our empirical modeling using (1) the FDA-approved UVa/Padova simulator with 30 virtual patients and (2) clinical data of 5 type 1 diabetic patients under natural living conditions. Compared to a forgetting-factor-based recursive ARX model of the same order, the EKF model predictions have higher fit, and significantly better temporal gain and J index and thus are superior in early detection of upward and downward trends in glucose. The EKF based state-space model developed in this article is particularly suitable for model-based state-feedback control designs since the Kalman filter estimates the state variable of the glucose dynamics based on the measured glucose time series. In addition, since the model parameters are estimated in real time, this model is also suitable for adaptive control. © 2014 Diabetes Technology Society.

  1. Detection of glycemic abnormalities in adolescents with beta thalassemia using continuous glucose monitoring and oral glucose tolerance in adolescents and young adults with β-thalassemia major: Pilot study

    Directory of Open Access Journals (Sweden)

    Ashraf T Soliman

    2013-01-01

    Full Text Available Background: Both insulin deficiency and resistance are reported in patients with β-thalassemia major (BTM. The use of continuous blood glucose monitoring (CGM, among the different methods for early detection of glycemic abnormalities, has not been studied thoroughly in these adolescents. Materials and Methods: To assess the oralglucose tolerance (OGT and 72-h continuous glucose concentration by the continuous glucose monitoring system (CGMS and calculate homeostatic model assessment (HOMA, and the quantitative insulin sensitivity check index (QUICKI was conducted in 16 adolescents with BTM who were receiving regular blood transfusions every 2-4 weeks and iron-chelation therapy since early childhood. Results: Sixteen adolescents with BTM (age: 19.75 ± 3 years were investigated. Using OGTT, (25% had impaired fasting blood (plasma glucose concentration (BG (>5.6 mmol/L. 2-h after the glucose load, one of them had BG = 16.2 mmol/L (diabetic and two had impaired glucose tolerance (IGT (BG > 7.8 and 11.1 mmol/L and 9 with IGT (56%. HOMA and QUICKI revealed levels 0.33 (0.36 ± 0.03, respectively, ruling out significant insulin resistance in these adolescents. There was a significant negative correlation between the β-cell function (B% on one hand and the fasting and the 2-h BG (r=−0.6, and − 0.48, P < 0.01, respectively on the other hand. Neither fasting serum insulin nor c-peptide concentrations were correlated with fasting BG or ferritin levels. The average and maximum blood glucose levels during CGM were significantly correlated with the fasting BG (r = 0.68 and 0.39, respectively, with P < 0.01 and with the BG at 2-hour after oral glucose intake (r = 0.87 and 0.86 respectively, with P < 0.001. Ferritin concentrations were correlated with the fasting BG and the 2-h blood glucose levels in the OGTT (r = 0.52, and r = 0.43, respectively, P < 0.01 as well as with the average BG recorded by CGM (r = 0.75, P < 0.01. Conclusion: CGM has proven to

  2. IDegLira Improves Both Fasting and Postprandial Glucose Control as Demonstrated Using Continuous Glucose Monitoring and a Standardized Meal Test

    DEFF Research Database (Denmark)

    Holst, Jens J; Buse, John B; Rodbard, Helena W

    2016-01-01

    OBJECTIVE: IDegLira is a novel, fixed-ratio combination of the long-acting basal insulin, insulin degludec, and the long-acting glucagon-like peptide-1 analog liraglutide. We studied the effect of IDegLira versus its components on postprandial glucose (PPG) in type 2 diabetes. METHODS: In this su...

  3. Continuous Glucose Monitoring

    Science.gov (United States)

    ... Kidney Disease Weight Management Liver Disease Urologic Diseases Endocrine Diseases Diet & Nutrition Blood Diseases Diagnostic Tests La información ... Kidney Disease Weight Management Liver Disease Urologic Diseases Endocrine Diseases Diet & Nutrition Blood Diseases Diagnostic Tests La información ...

  4. Real-time continuous glucose monitoring as a tool to prevent severe hypoglycaemia in selected pregnant women with Type 1 diabetes

    DEFF Research Database (Denmark)

    Secher, A L; Stage, E; Ringholm, Lene

    2014-01-01

    AIMS: Among women with Type 1 diabetes who have had severe hypoglycaemia the year before pregnancy, 70% also experience this complication in pregnancy, and particularly in the first half of pregnancy. We evaluated whether routine use of real-time continuous glucose monitoring from early pregnancy...... onwards could prevent severe hypoglycaemia in these women. METHODS: All 136 consecutive pregnant women with Type 1 diabetes referred to our centre were asked about severe hypoglycaemic events in the year before pregnancy and early in pregnancy at their first antenatal visit. Women with a relevant recent...... history were informed about their additional high risk of severe hypoglycaemia, their treatment was focused on restricted insulin doses during the first 16 gestational weeks, and they were offered real-time continuous glucose monitoring on top of self-monitored plasma glucose measurements. RESULTS: Among...

  5. Effect of Continuous Glucose Monitoring on Glycemic Control, Acute Admissions, and Quality of Life: A Real-World Study.

    Science.gov (United States)

    Charleer, Sara; Mathieu, Chantal; Nobels, Frank; De Block, Christophe; Radermecker, Regis P; Hermans, Michel P; Taes, Youri; Vercammen, Chris; T'Sjoen, Guy; Crenier, Laurent; Fieuws, Steffen; Keymeulen, Bart; Gillard, Pieter

    2018-03-01

    Randomized controlled trials evaluating real-time continuous glucose monitoring (RT-CGM) patients with type 1 diabetes (T1D) show improved glycemic control, but limited data are available on real-world use. To assess impact of RT-CGM in real-world settings on glycemic control, hospital admissions, work absenteeism, and quality of life (QOL). Prospective, observational, multicenter, cohort study. A total of 515 adults with T1D on continuous subcutaneous insulin infusion (CSII) therapy starting in the Belgian RT-CGM reimbursement program. Initiation of RT-CGM reimbursement. Hemoglobin A1c (HbA1c) evolution from baseline to 12 months. Between September 1, 2014, and December 31, 2016, 515 adults entered the reimbursement system. Over this period, 417 (81%) patients used RT-CGM for at least 12 months. Baseline HbA1c was 7.7 ± 0.9% (61 ± 9.8 mmol/mol) and decreased to 7.4 ± 0.8% (57 ± 8.7 mmol/mol) at 12 months (P < 0.0001). Subjects who started RT-CGM because of insufficient glycemic control showed stronger decrease in HbA1c at 4, 8, and 12 months compared with patients who started because of hypoglycemia or pregnancy. In the year preceding reimbursement, 16% of patients were hospitalized for severe hypoglycemia or ketoacidosis in contrast to 4% (P < 0.0005) the following year, with decrease in admission days from 54 to 18 per 100 patient years (P < 0.0005). In the same period, work absenteeism decreased and QOL improved significantly, with strong decline in fear of hypoglycemia. Sensor-augmented pump therapy in patients with T1D followed in specialized centers improves HbA1c, fear of hypoglycemia, and QOL, whereas work absenteeism and admissions for acute diabetes complications decreased.

  6. Comparison of vildagliptin twice daily vs. sitagliptin once daily using continuous glucose monitoring (CGM: Crossover pilot study (J-VICTORIA study

    Directory of Open Access Journals (Sweden)

    Sakamoto Masaya

    2012-08-01

    Full Text Available Abstract Background No previous studies have compared the DPP-4 inhibitors vildagliptin and sitagliptin in terms of blood glucose levels using continuous glucose monitoring (CGM and cardiovascular parameters. Methods Twenty patients with type 2 diabetes mellitus were randomly allocated to groups who received vildagliptin then sitagliptin, or vice versa. Patients were hospitalized at 1 month after starting each drug, and CGM was used to determine: 1 mean (± standard deviation 24-hour blood glucose level, 2 mean amplitude of glycemic excursions (MAGE, 3 fasting blood glucose level, 4 highest postprandial blood glucose level and time, 5 increase in blood glucose level after each meal, 6 area under the curve (AUC for blood glucose level ≥180 mg/dL within 3 hours after each meal, and 7 area over the curve (AOC for daily blood glucose level Results The mean 24-hour blood glucose level was significantly lower in patients taking vildagliptin than sitagliptin (142.1 ± 35.5 vs. 153.2 ± 37.0 mg/dL; p = 0.012. In patients taking vildagliptin, MAGE was significantly lower (110.5 ± 33.5 vs. 129.4 ± 45.1 mg/dL; p = 0.040, the highest blood glucose level after supper was significantly lower (206.1 ± 40.2 vs. 223.2 ± 43.5 mg/dL; p = 0.015, the AUC (≥180 mg/dL within 3 h was significantly lower after breakfast (484.3 vs. 897.9 mg/min/dL; p = 0.025, and urinary CPR level was significantly higher (97.0 ± 41.6 vs. 85.2 ± 39.9 μg/day; p = 0.008 than in patients taking sitagliptin. There were no significant differences in plasma HbA1c, GA, 1,5AG, IRI, CPR, BNP, or PAI-1 levels between patients taking vildagliptin and sitagliptin. Conclusions CGM showed that mean 24-h blood glucose, MAGE, highest blood glucose level after supper, and hyperglycemia after breakfast were significantly lower in patients with type 2 diabetes mellitus taking vildagliptin than those taking sitagliptin. There

  7. Multi-stage Continuous Culture Fermentation of Glucose-Xylose Mixtures to Fuel Ethanol using Genetically Engineered Saccharomyces cerevisiae 424A

    Science.gov (United States)

    Multi-stage continuous (chemostat) culture fermentation (MCCF) with variable fermentor volumes was carried out to study utilizing glucose and xylose for ethanol production by means of mixed sugar fermentation (MSF). Variable fermentor volumes were used to enable enhanced sugar u...

  8. Continuous glucose monitoring adds information beyond HbA1c in well-controlled diabetes patients with early cardiovascular autonomic neuropathy

    DEFF Research Database (Denmark)

    Fleischer, Jesper; Laugesen, Esben; Cichosz, Simon Lebech

    2017-01-01

    AIMS: Hyperglycemia as evaluated by HbA1c is a risk factor for the development of cardiovascular autonomic neuropathy (CAN). The aim of the present study was to investigate whether continuous glucose monitoring (CGM) may add information beyond HbA1c in patients with type 2 diabetes and CAN. METHO...

  9. Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial

    NARCIS (Netherlands)

    van Beers, Cornelis A. J.; DeVries, J. Hans; Kleijer, Susanne J.; Smits, Mark M.; Geelhoed-Duijvestijn, Petronella H.; Kramer, Mark H. H.; Diamant, Michaela; Snoek, Frank J.; Serné, Erik H.

    2016-01-01

    Patients with type 1 diabetes who have impaired awareness of hypoglycaemia have a three to six times increased risk of severe hypoglycaemia. We aimed to assess whether continuous glucose monitoring (CGM) improves glycaemia and prevents severe hypoglycaemia compared with self-monitoring of blood

  10. [Current status and recommendations on the use of continuous blood glucose monitoring systems in children and adolescents with type 1 diabetes mellitus].

    Science.gov (United States)

    Torres Lacruz, M; Barrio Castellanos, R; García Cuartero, B; Gómez Gila, A; González Casado, I; Hermoso López, F; Luzuriaga Tomás, C; Oyarzabal Irigoyen, M; Rica Etxebarria, I; Rodríguez Rigual, M

    2011-08-01

    Glucose monitoring methods have made great advances in the last decade with the appearance of the continuous glucose monitoring systems (CGMS) that measure the glucose levels in the interstitial liquid, providing information about glucose patterns and trends, but do not replace the self-monitoring of capillary glucose. Improvement in diabetes control using the CGMS depends on the motivation and training received by the patient and family and on the continuity in its use. Due to the development and widespread use of these systems in clinical practice, the diabetes group of the Sociedad Española de Endocrinología Pediátrica has drafted a document of consensus for their indication and use in children and adolescents. Only a limited number of trials have been performed in children and adolescent populations. More data are needed on the use of this technology in order to define the impact on metabolic control. Copyright © 2010 Asociación Española de Pediatría. Published by Elsevier Espana. All rights reserved.

  11. Comparison of vildagliptin twice daily vs. sitagliptin once daily using continuous glucose monitoring (CGM): Crossover pilot study (J-VICTORIA study)

    Science.gov (United States)

    2012-01-01

    Background No previous studies have compared the DPP-4 inhibitors vildagliptin and sitagliptin in terms of blood glucose levels using continuous glucose monitoring (CGM) and cardiovascular parameters. Methods Twenty patients with type 2 diabetes mellitus were randomly allocated to groups who received vildagliptin then sitagliptin, or vice versa. Patients were hospitalized at 1 month after starting each drug, and CGM was used to determine: 1) mean (± standard deviation) 24-hour blood glucose level, 2) mean amplitude of glycemic excursions (MAGE), 3) fasting blood glucose level, 4) highest postprandial blood glucose level and time, 5) increase in blood glucose level after each meal, 6) area under the curve (AUC) for blood glucose level ≥180 mg/dL within 3 hours after each meal, and 7) area over the curve (AOC) for daily blood glucose level vildagliptin than sitagliptin (142.1 ± 35.5 vs. 153.2 ± 37.0 mg/dL; p = 0.012). In patients taking vildagliptin, MAGE was significantly lower (110.5 ± 33.5 vs. 129.4 ± 45.1 mg/dL; p = 0.040), the highest blood glucose level after supper was significantly lower (206.1 ± 40.2 vs. 223.2 ± 43.5 mg/dL; p = 0.015), the AUC (≥180 mg/dL) within 3 h was significantly lower after breakfast (484.3 vs. 897.9 mg/min/dL; p = 0.025), and urinary CPR level was significantly higher (97.0 ± 41.6 vs. 85.2 ± 39.9 μg/day; p = 0.008) than in patients taking sitagliptin. There were no significant differences in plasma HbA1c, GA, 1,5AG, IRI, CPR, BNP, or PAI-1 levels between patients taking vildagliptin and sitagliptin. Conclusions CGM showed that mean 24-h blood glucose, MAGE, highest blood glucose level after supper, and hyperglycemia after breakfast were significantly lower in patients with type 2 diabetes mellitus taking vildagliptin than those taking sitagliptin. There were no significant differences in BNP and PAI-1 levels between patients taking vildagliptin and

  12. AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS AND AMERICAN COLLEGE OF ENDOCRINOLOGY 2018 POSITION STATEMENT ON INTEGRATION OF INSULIN PUMPS AND CONTINUOUS GLUCOSE MONITORING IN PATIENTS WITH DIABETES MELLITUS.

    Science.gov (United States)

    Grunberger, George; Handelsman, Yehuda; Bloomgarden, Zachary T; Fonseca, Vivian A; Garber, Alan J; Haas, Richard A; Roberts, Victor L; Umpierrez, Guillermo E

    2018-03-01

    This document represents the official position of the American Association of Clinical Endocrinologists and American College of Endocrinology. Where there are no randomized controlled trials or specific U.S. FDA labeling for issues in clinical practice, the participating clinical experts utilized their judgment and experience. Every effort was made to achieve consensus among the committee members. Position statements are meant to provide guidance, but they are not to be considered prescriptive for any individual patient and cannot replace the judgment of a clinician. AACE/ACE Task Force on Integration of Insulin Pumps and Continuous Glucose Monitoring in the Management of Patients With Diabetes Mellitus Chair George Grunberger, MD, FACP, FACE Task Force Members Yehuda Handelsman, MD, FACP, FNLA, MACE Zachary T. Bloomgarden, MD, MACE Vivian A. Fonseca, MD, FACE Alan J. Garber, MD, PhD, FACE Richard A. Haas, MD, FACE Victor L. Roberts, MD, MBA, FACP, FACE Guillermo E. Umpierrez, MD, CDE, FACP, FACE Abbreviations: AACE = American Association of Clinical Endocrinologists ACE = American College of Endocrinology A1C = glycated hemoglobin BGM = blood glucose monitoring CGM = continuous glucose monitoring CSII = continuous subcutaneous insulin infusion DM = diabetes mellitus FDA = Food & Drug Administration MDI = multiple daily injections T1DM = type 1 diabetes mellitus T2DM = type 2 diabetes mellitus SAP = sensor-augmented pump SMBG = self-monitoring of blood glucose STAR 3 = Sensor-Augmented Pump Therapy for A1C Reduction phase 3 trial.

  13. Toward an agent-based patient-physician model for the adoption of continuous glucose monitoring technology.

    Science.gov (United States)

    Verella, J Tipan; Patek, Stephen D

    2009-03-01

    Health care is a major component of the U.S. economy, and tremendous research and development efforts are directed toward new technologies in this arena. Unfortunately few tools exist for predicting outcomes associated with new medical products, including whether new technologies will find widespread use within the target population. Questions of technology adoption are rife within the diabetes technology community, and we particularly consider the long-term prognosis for continuous glucose monitoring (CGM) technology. We present an approach to the design and analysis of an agent model that describes the process of CGM adoption among patients with type 1 diabetes mellitus (T1DM), their physicians, and related stakeholders. We particularly focus on patient-physician interactions, with patients discovering CGM technology through word-of-mouth communication and through advertising, applying pressure to their physicians in the context of CGM device adoption, and physicians, concerned about liability, looking to peers for a general level of acceptance of the technology before recommending CGM to their patients. Repeated simulation trials of the agent-based model show that the adoption process reflects the heterogeneity of the adopting community. We also find that the effect of the interaction between patients and physicians is agents. Each physician, say colored by the nature of the environment as defined by the model parameters. We find that, by being able to represent the diverse perspectives of different types of stakeholders, agent-based models can offer useful insights into the adoption process. Models of this sort may eventually prove to be useful in helping physicians, other health care providers, patient advocacy groups, third party payers, and device manufacturers understand the impact of their decisions about new technologies. (c) 2009 Diabetes Technology Society.

  14. Effects of Acute Ingestion of Native Banana Starch on Glycemic Response Evaluated by Continuous Glucose Monitoring in Obese and Lean Subjects

    Directory of Open Access Journals (Sweden)

    Guadalupe Jiménez-Domínguez

    2015-07-01

    Full Text Available An abnormal glycemic profile, including postprandial glycemia and acute glucose spikes, precedes the onset of overt diabetes in obese subjects. Previous studies have shown the beneficial effects of chronic native banana starch (NBS supplementation. In this study, we examined the effects of acute ingestion of NBS on glycemic profiles by means of continuous glucose monitoring in obese and lean subjects. In a crossover study, obese and lean subjects consumed beverages containing either 38.3 g of NBS or 38.3 g of digestible corn starch (DCS twice daily during 4 days. On day 5, a 3-h meal tolerance test (MTT was performed to evaluate glucose and insulin responses. After 1 week of washout period, treatments were inverted. NBS supplementation reduced the 48-h glycemia AUC in lean, obese, and in the combined group of lean and obese subjects in comparison with DCS. Postprandial glucose and insulin responses at MTT were reduced after NBS in comparison with DCS in all groups. However, no changes were observed in glycemic variability (GV indexes between groups. In conclusion, acute NBS supplementation improved postprandial glucose and insulin responses in obese and lean subjects during 48 h of everyday life and at MTT. Further research to elucidate the mechanism behind these changes is required.

  15. Continuous Glucose Monitoring vs Conventional Therapy for Glycemic Control in Adults With Type 1 Diabetes Treated With Multiple Daily Insulin Injections: The GOLD Randomized Clinical Trial.

    Science.gov (United States)

    Lind, Marcus; Polonsky, William; Hirsch, Irl B; Heise, Tim; Bolinder, Jan; Dahlqvist, Sofia; Schwarz, Erik; Ólafsdóttir, Arndís Finna; Frid, Anders; Wedel, Hans; Ahlén, Elsa; Nyström, Thomas; Hellman, Jarl

    2017-01-24

    The majority of individuals with type 1 diabetes do not meet recommended glycemic targets. To evaluate the effects of continuous glucose monitoring in adults with type 1 diabetes treated with multiple daily insulin injections. Open-label crossover randomized clinical trial conducted in 15 diabetes outpatient clinics in Sweden between February 24, 2014, and June 1, 2016 that included 161 individuals with type 1 diabetes and hemoglobin A1c (HbA1c) of at least 7.5% (58 mmol/mol) treated with multiple daily insulin injections. Participants were randomized to receive treatment using a continuous glucose monitoring system or conventional treatment for 26 weeks, separated by a washout period of 17 weeks. Difference in HbA1c between weeks 26 and 69 for the 2 treatments. Adverse events including severe hypoglycemia were also studied. Among 161 randomized participants, mean age was 43.7 years, 45.3% were women, and mean HbA1c was 8.6% (70 mmol/mol). A total of 142 participants had follow-up data in both treatment periods. Mean HbA1c was 7.92% (63 mmol/mol) during continuous glucose monitoring use and 8.35% (68 mmol/mol) during conventional treatment (mean difference, -0.43% [95% CI, -0.57% to -0.29%] or -4.7 [-6.3 to -3.1 mmol/mol]; P < .001). Of 19 secondary end points comprising psychosocial and various glycemic measures, 6 met the hierarchical testing criteria of statistical significance, favoring continuous glucose monitoring compared with conventional treatment. Five patients in the conventional treatment group and 1 patient in the continuous glucose monitoring group had severe hypoglycemia. During washout when patients used conventional therapy, 7 patients had severe hypoglycemia. Among patients with inadequately controlled type 1 diabetes treated with multiple daily insulin injections, the use of continuous glucose monitoring compared with conventional treatment for 26 weeks resulted in lower HbA1c. Further research is needed to assess clinical outcomes and longer

  16. Comparison of Efficacy and Safety of Lispro and Aspart Evaluated by Continuous Glucose Monitoring System in Patients with Newly Diagnosed Type 2 Diabetes

    Directory of Open Access Journals (Sweden)

    Bing-li Liu

    2018-01-01

    Full Text Available Objective. To compare the effect of the rapid-acting insulin analogues (RAIAs aspart (NovoRapid and lispro (Prandilin on glycemic variations by continuous glucose monitoring system (CGMS in patients within newly diagnosed type 2 diabetes mellitus (T2DM receiving continuous subcutaneous insulin infusion (CSII and metformin intensive therapy. Methods. This is a single-blind randomized controlled trial. A total of 110 patients with newly diagnosed T2DM and with hemoglobin A1c (HbA1c% above 9% was hospitalized and randomly divided into two groups: group Asp (NovoRapid group and group Lis (Prandilin group. They all received CSII and metformin therapy. Treatments were maintained for 2-3 weeks after the glycaemic target was reached. C-peptide and insulin and fructosamine were determined. CGMS was continuously applied for 4 days after reaching the glycemic target. Results. There were no significant differences in daily dosages of insulin, fasting plasma C-P and 2 h postprandial C-P and insulin, and fructosamine at the baseline and endpoint between the groups Asp and Lis. No significant differences were seen in the 24 h mean amplitude of glycemic excursions (MAGE, 24 h mean blood glucose (MBG, the standard deviation of the MBG (SDBG, fasting blood glucose, number of glycemic excursion (NGE, and the incidence of hypoglycemia between the two groups. Similarly, no significant differences were found in areas under the curve (AUC of glucose above 10.0 mmol/L or the decremental area over the curve (AOC of glucose below 3.9 mmol/L between the two groups. Conclusions. Lispro and aspart had the similar ability to control the glycemic variations in patients with newly diagnosed T2DM. This study was registered with ClinicalTrials.gov, number ChiCTR-IPR-17010338.

  17. Keeping Up with the Diabetes Technology: 2016 Endocrine Society Guidelines of Insulin Pump Therapy and Continuous Glucose Monitor Management of Diabetes.

    Science.gov (United States)

    Galderisi, Alfonso; Schlissel, Elise; Cengiz, Eda

    2017-09-23

    Decades after the invention of insulin pump, diabetes management has encountered a technology revolution with the introduction of continuous glucose monitoring, sensor-augmented insulin pump therapy and closed-loop/artificial pancreas systems. In this review, we discuss the significance of the 2016 Endocrine Society Guidelines for insulin pump therapy and continuous glucose monitoring and summarize findings from relevant diabetes technology studies that were conducted after the publication of the 2016 Endocrine Society Guidelines. The 2016 Endocrine Society Guidelines have been a great resource for clinicians managing diabetes in this new era of diabetes technology. There is good body of evidence indicating that using diabetes technology systems safely tightens glycemic control while managing both type 1 and type 2 diabetes. The first-generation diabetes technology systems will evolve as we gain more experience and collaboratively work to improve them with an ultimate goal of keeping people with diabetes complication and burden-free until the cure for diabetes becomes a reality.

  18. Pre-exercise blood glucose affects glycemic variation of aerobic exercise in patients with type 2 diabetes treated with continuous subcutaneous insulin infusion.

    Science.gov (United States)

    Hu, Yun; Zhang, Dan-Feng; Dai, Lu; Li, Zheng; Li, Hui-Qin; Li, Feng-Fei; Liu, Bing-Li; Sun, Xiao-Juan; Ye, Lei; He, Ke; Ma, Jian-Hua

    2018-05-03

    Considering the insulin sensitivity may increase by exercise particularly in patients with type 2 diabetes (T2D), glycemic variation during exercise needs to be studied when the patients are treated with insulin. This study aimed to explore the influence factors of the efficacy and safety of aerobic exercise in patients with T2D treated with Continuous Subcutaneous Insulin Infusion (CSII). A total of 267 patients with T2D, treated with CSII, were included. Glycemic variations were assessed by continuous glucose monitoring (CGM). Patients were asked to complete 30 min aerobic exercise for at least one time during CGM. The patients were divided into effective and ineffective group by incremental glucose area under curve from 0 to 60 min after exercise (AUC 0-60 min ). The patients completed a total of 776 times of aerobic exercises. Blood glucose decreased fastest in the first 60 min of exercise. Pre-exercise blood glucose (PEBG) was negatively correlated with AUC 0-60 min (standardized β = -0.386, P AUC of blood glucose ≤ 4.4 mmol/L (standardized β = -0.078, P = 0.034), and was significantly higher in effective group than in ineffective group (P AUC 0-60 min during post-dinner was significantly higher than that during pre-lunch, post-lunch and pre-dinner (P  16.7 mmol/L. Post-dinner exercise decreases the blood glucose better than other periods of the day. ChiCTR-ONC-17010400, www.chictr.org.cn. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Analysis of the exopolysaccharides produced by Lactobacillus delbrueckii subsp. bulgaricus NCFB 2772 grown in continuous culture on glucose and fructose.

    NARCIS (Netherlands)

    Grobben, G.J.; Casteren, van W.H.M.; Schols, H.A.; Oosterveld, A.; Sala, G.; Smith, M.R.; Sikkema, J.; Bont, de J.A.M.

    1997-01-01

    The exopolysaccharides produced by Lactobacillus delbrueckii subsp. bulgaricus NCFB 2772 grown in defined medium were investigated. At equal cell densities, the strain produced 95 mg l−1 exopolysaccharides with glucose and 30 mg l−1 with fructose as the carbohydrate source. High-performance

  20. Selection of the optimum font type and size interface for on screen continuous reading by young adults: an ergonomic approach.

    Science.gov (United States)

    Banerjee, Jayeeta; Bhattacharyya, Moushum

    2011-12-01

    There is a rapid shifting of media: from printed paper to computer screens. This transition is modifying the process of how we read and understand text. The efficiency of reading is dependent on how ergonomically the visual information is presented. Font types and size characteristics have been shown to affect reading. A detailed investigation of the effect of the font type and size on reading on computer screens has been carried out by using subjective, objective and physiological evaluation methods on young adults. A group of young participants volunteered for this study. Two types of fonts were used: Serif fonts (Times New Roman, Georgia, Courier New) and Sans serif fonts (Verdana, Arial, Tahoma). All fonts were presented in 10, 12 and 14 point sizes. This study used a 6 X 3 (font type X size) design matrix. Participants read 18 passages of approximately the same length and reading level on a computer monitor. Reading time, ranking and overall mental workload were measured. Eye movements were recorded by a binocular eye movement recorder. Reading time was minimum for Courier New l4 point. The participants' ranking was highest and mental workload was least for Verdana 14 point. The pupil diameter, fixation duration and gaze duration were least for Courier New 14 point. The present study recommends using 14 point sized fonts for reading on computer screen. Courier New is recommended for fast reading while for on screen presentation Verdana is recommended. The outcome of this study will help as a guideline to all the PC users, software developers, web page designers and computer industry as a whole.

  1. Efficacy and safety of teneligliptin in addition to insulin therapy in type 2 diabetes mellitus patients on hemodialysis evaluated by continuous glucose monitoring.

    Science.gov (United States)

    Yajima, Takahiro; Yajima, Kumiko; Hayashi, Makoto; Takahashi, Hiroshi; Yasuda, Keigo

    2016-12-01

    Appropriate glycemic control without hypoglycemia is important in patients with type 2 diabetes on hemodialysis. Teneligliptin, a novel dipeptidyl peptidase-4 inhibitor, can be used without dose adjustment for these patients. Using continuous glucose monitoring (CGM), we evaluated the efficacy and safety of adding teneligliptin to insulin therapy. Twenty-one type 2 diabetes mellitus patients on hemodialysis treated with insulin were enrolled. After the adjustment of insulin dose, their blood glucose level was monitored by CGM. Insulin dose was reduced after teneligliptin administration. The median total daily insulin dose significantly reduced from 18 (9-24)U to 6 (0-14)U (p1). Maximum, mean, and standard deviation of blood glucose level on the hemodialysis and non-hemodialysis days did not change after teneligliptin administration. However, minimum blood glucose level was significantly elevated on the hemodialysis day after teneligliptin administration (from 3.9±1.0mmol/L to 4.4±0.9mmol/L, p=0.040). The incidence of asymptomatic hypoglycemia on the hemodialysis day detected by CGM significantly decreased from 38.1% to 19.0% (p=0.049). Teneligliptin may contribute toward reducing the total daily insulin dose and preventing hypoglycemic events on the hemodialysis day in type 2 diabetes mellitus patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Continuous subcutaneous infusion of glucagon-like peptide 1 lowers plasma glucose and reduces appetite in type 2 diabetic patients

    DEFF Research Database (Denmark)

    Toft-Nielsen, M B; Madsbad, Sten; Holst, J J

    1999-01-01

    OBJECTIVE: The gut hormone glucagon-like peptide 1 (GLP-1) has insulinotropic and anorectic effects during intravenous infusion and has been proposed as a new treatment for type 2 diabetes and obesity. The effect of a single subcutaneous injection is brief because of rapid degradation. We therefore......, previously shown to lower blood glucose effectively in type 2 diabetic patients. Fasting plasma glucose (day 2) decreased from 14.1 +/- 0.9 (saline) to 12.2 +/- 0.7 mmol/l (GLP-1), P = 0.009, and 24-h mean plasma glucose decreased from 15.4 +/- 1.0 to 13.0 +/- 1.0 mmol/l, P = 0.0009. Fasting and total area...... under the curve for insulin and C-peptide levels were significantly higher during the GLP-1 administration, whereas glucagon levels were unchanged. Neither triglycerides nor free fatty acids were affected. GLP-1 administration decreased hunger and prospective food intake and increased satiety, whereas...

  3. Use of real time continuous glucose monitoring and intravenous insulin in type 1 diabetic mothers to prevent respiratory distress and hypoglycaemia in infants

    Directory of Open Access Journals (Sweden)

    Passaro Patrizia

    2008-07-01

    Full Text Available Abstract Background Pregnancy in Type 1 diabetic patients is a precarious condition, both for mother and fetus with increased the risk of prematurity and, immediately after delivery with risk of respiratory distress syndrome and hypoglycaemia in newborns. A strict control and monitoring of diabetes throughout pregnancy is important in reducing the impact of the disease on the fetus and newborn. In recent years many new technologies have been introduced to ameliorate diabetes monitoring, where the last is the Real-time Continuous Glucose Monitoring System (RT-CGMS. Methods In the last three years, 72 h continuous glucose monitoring system (RT-CGMS (Medtronic, CA was performed in 18 pregnant women with Type 1 diabetes in two moments of pregnancy: during treatment with betamethasone to prevent respiratory distress and during delivery. In both cases insulin was administered intravenous and the dose was changed on the basis of glycaemia. Results The results present the use of this new technique during two topics moments of pregnancy of type 1 diabetes patients when is very important intensively to monitor diabetes and to obtain the well being of the fetus. No infant experimented hypoglycaemia or respiratory distress syndrome at the moment and in the first hours after the birth. Conclusion We wish to stress the importance reducing glycaemia during administration of betamethasone and during labor. It is conceivable that the scarce attention paid to monitoring glucose levels in diabetic mothers during labor in gynaecological world may be due to the difficulty in glucose monitoring with the devices until now available. Hopefully, our anecdotal account may prompt improvements with RT-CGMS, and may lead to a better approach to the problem, thereby changing the prognosis of infants born to diabetic mothers.

  4. Influence of phase separation on the anaerobic digestion of glucose: maximum COD turnover rate during continuous operation

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, A; Van Andel, J G; Breure, A M; Van Deursen, A

    1980-01-01

    A mineral medium containing 1% of glucose as the main carbon source was subjected to one-phase and two-phase anaerobic digestion processes under comparable conditions. The one-phase system combined acidogenic and methanogenic populations allowing a complete conversion of the carbon source into gaseous end products and biomass. The two-phase system consists of an acid reactor and a methane reactor connected in series allowing sequential acidogenesis and methanogenesis. Performance of the one-phase system is compared with that of the two-phase system. Maximum turnover of COD was determined for each system. Maximum specific sludge loading of the two-phase system was more than three times higher than that of the one-phase system. Effects of overloading each system were determined. The eco-physiological significance of phase separation is discussed briefly. (2 diagrams, 5 graphs, 41 references, 5 tables)

  5. Glycemic variability and insulin needs in patients with type 1 diabetes mellitus supplemented with vitamin D: a pilot study using continuous glucose monitoring system.

    Science.gov (United States)

    Felício, Karem Miléo; de Souza, Ana Carolina Contente Braga; Neto, João Felício Abrahão; de Melo, Franciane Trindade Cunha; Carvalho, Carolina Tavares; Arbage, Thaís Pontes; de Rider Brito, Hana Andrade; Peixoto, Amanda Soares; de Oliveira, Alana Ferreira; de Souza Resende, Fabricio; Reis, Scarlatt Sousa; Motta, Ana Regina; da Costa Miranda, Henrique; Janaú, Luísa Corrêa; Yamada, Elizabeth Sumi; Felício, João Soares

    2017-06-15

    Recent studies suggest that glycemic variability could influence the risk of complications in type 1 diabetes mellitus (T1DM). There are no data about the action of vitamin D (VD) on glycemic variability. Our pilot study aims to evaluate glycemic variability and insulin needs in patients with T1DM supplemented with VD. 22 patients received doses of 4000 and 10000 IU/day of cholecalciferol for 12 weeks, according to the patient's baseline VD levels and underwent continuous glucose monitoring system. Correlations were found between percentage variation (∆) of glycemia standard deviation (∆SDG), calculated using continuous glucose monitoring, with ∆ of basal (r= 0.6; p needed by patients is lower when VD status is better. We divided patients in two subgroups: SDG improved (subgroup 1; n =12 (55%)) and SDG worsened (subgroup 2; n =10 (45%)). Group 1, compared to subgroup 2, required a lower insulin dose (∆basal insulin dose = -8.0 vs 6.3%; p needs and lower frequency of hypoglycemia in patients with T1DM. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  6. Continuous Glucose Monitoring Can Uncover Mistakes in Self-Treatment of Hypoglycemia in Patients with Type I Diabetes Mellitus

    Czech Academy of Sciences Publication Activity Database

    Brož, J.; Urbanová, J.; Janíčková Žďárská, D.; Doničová, V.; Brabec, Marek

    2014-01-01

    Roč. 63, Supplement 1 (2014), A221-A221 ISSN 0012-1797. [American Diabetes Association. Scientific Sessions /74./. 13.06.2014-17.06.2014, San Francisco] Institutional support: RVO:67985807 Keywords : continuous monitoring * type I diabetes * semiparametric modeling Subject RIV: FB - Endocrinology, Diabetology, Metabolism, Nutrition

  7. Continuous Glucose Monitoring Can Uncover Mistakes in Self-Treatment of Hypoglycemia in Patients with Type I Diabetes Mellitus

    Czech Academy of Sciences Publication Activity Database

    Brož, J.; Urbanová, J.; Janíčková Žďárská, D.; Doničová, V.; Brabec, Marek

    2014-01-01

    Roč. 16, Supplement 1 (2014), A35-A35 ISSN 1520-9156. [American Diabetes Association. Scientific Sessions /74./. 13.06.2014-17.06.2014, San Francisco] Institutional support: RVO:67985807 Keywords : continuous monitoring * type I diabetes * semiparametric modeling Subject RIV: FB - Endocrinology, Diabetology, Metabolism, Nutrition

  8. Rupture and Continuity in the Socio-emotional Framework of Primary School Reading Books in the later Years of the Franco Regime (1959-1975

    Directory of Open Access Journals (Sweden)

    Ana Badanelli Rubio

    2015-07-01

    Full Text Available Reading books were one of the favorite textual genres of the Franco Regime, used as a privileged vehicle for the transmission of knowledge, values and emotions. This article explores the evolution of their characteristics and contents during the late Franco dictatorship (tardofranquismo. During the first and second phases of Franco Regime, textbooks contained heavy doses of ideological indoctrination, both political and religious. The inculcation of emotions and sentiments in school texts has been demonstrated; in the early decades of the regime, the language employed in the writing of textbooks had the specific objective of manipulating and persuading as a means to control and shape the emotional structure of childhood. There is debate as to what extent and in what manner the nature of the texts (the kinds of readings and their underlying messages were modified under the new economic policy and technocracy. The study examines ruptures and continuities that appear in reading books and in their texts, focusing on publishers and authors on the one hand – the messages and their written and iconic languages – and on the emotions that are transmitted through both routes on the other. The economic opening and political turn of the regime’s later years did lead to certain aesthetic and didactic facelifts in the manuals. However, reading books not only changed their appearance; this study brings to light the changes in socio-emotional schemes, changes that took place slowly and gradually. The projected and stimulated emotions began to be directed more at the world of the children and towards a more constructive way reading, moving away from socio-political objectives

  9. Short-term use of continuous glucose monitoring system adds to glycemic control in young type 1 diabetes mellitus patients in the long run: A clinical trial

    Directory of Open Access Journals (Sweden)

    Bukara-Radujković Gordana

    2011-01-01

    Full Text Available Background/Aim. Balancing strict glycemic control with setting realistic goals for each individual child and family can optimize growth, ensure normal pubertal development and emotional maturation, and control long term complications in children with type 1 diabetes (T1DM. The aim of this study was to evaluate the efficacy of short-term continuous glucose monitoring system (CGMS application in improvement of glycemic control in pediatric type 1 diabetes mellitus (T1DM patients. Methods. A total of 80 pediatric T1DM patients were randomly assigned into the experimental and the control group. The experimental group wore CGMS sensor for 72 hours at the beginning of the study. Self-monitored blood glucose (SMBG levels and hemoglobin A1c (HbA1c levels were obtained for both groups at baseline, and at 3 and 6 months. Results. There was a significant improvement in HbA1c (p < 0.001, in both the experimental and the control group, without a significant difference between the groups. Nevertheless, after 6 months the improvement of mean glycemia was noticed only in the experimental group. This finding was accompanied with a decrease in the number of hyperglycemic events and no increase in the number of hypoglycemic events in the experimental group. Conclusions. The results suggest that the CGMS can be considered as a valuable tool in treating pediatric T1DM patients, however further research is needed to more accurately estimate to what extent, if any, it outperforms intensive self-monitoring of blood glucose.

  10. Glucose and insulin dynamics associated with continuous rate infusion of dextrose solution or dextrose solution and insulin in healthy and endotoxin-exposed horses.

    Science.gov (United States)

    Han, Janet H; McKenzie, Harold C; McCutcheon, L Jill; Geor, Raymond J

    2011-04-01

    To investigate the effects of a continuous rate infusion (CRI) of dextrose solution or dextrose solution and insulin on glucose and insulin concentrations in healthy and endotoxin-exposed horses. 9 adult mares. During phase 1, treatments consisted of saline (0.9% NaCl) solution (control group; n = 4) or 20% dextrose solution (group 1; 4) administered IV as a 360-minute CRI. During phase 2, treatments consisted of 360-minute CRIs of 20% dextrose solution and insulin administered simultaneously at 367.6 mg/kg/h (30 kcal/kg/d) and 0.07 U/kg/h, respectively, in healthy horses (group 2; n = 4) or horses administered 35 ng of lipopolysaccharide/kg, IV, 24 hours before starting the dextrose solution and insulin CRIs (group 3; 4). A balanced crossover study design was used in both phases. Blood samples were collected for measurement of plasma glucose and insulin concentrations. Infusion of dextrose solution alone resulted in hyperglycemia for most of the 360-minute CRI. Insulin concentration increased significantly in group 1, compared with that in the control group. Mean insulin concentration of group 2 was significantly higher throughout most of the infusion period, compared with concentrations of the control group and group 1. Mean glucose concentration did not differ significantly between groups 2 and 3. Insulin infusion at a rate of 0.07 U/kg/h was found to be effective for the prevention of hyperglycemia when administered concurrently with dextrose solution. This rate was considered to be safe because horses did not become hypoglycemic during infusions of dextrose solution.

  11. Detection of correct and incorrect measurements in real-time continuous glucose monitoring systems by applying a postprocessing support vector machine.

    Science.gov (United States)

    Leal, Yenny; Gonzalez-Abril, Luis; Lorencio, Carol; Bondia, Jorge; Vehi, Josep

    2013-07-01

    Support vector machines (SVMs) are an attractive option for detecting correct and incorrect measurements in real-time continuous glucose monitoring systems (RTCGMSs), because their learning mechanism can introduce a postprocessing strategy for imbalanced datasets. The proposed SVM considers the geometric mean to obtain a more balanced performance between sensitivity and specificity. To test this approach, 23 critically ill patients receiving insulin therapy were monitored over 72 h using an RTCGMS, and a dataset of 537 samples, classified according to International Standards Organization (ISO) criteria (372 correct and 165 incorrect measurements), was obtained. The results obtained were promising for patients with septic shock or with sepsis, for which the proposed system can be considered as reliable. However, this approach cannot be considered suitable for patients without sepsis.

  12. Analysis of the Accuracy and Performance of a Continuous Glucose Monitoring Sensor Prototype: An In-Silico Study Using the UVA/PADOVA Type 1 Diabetes Simulator.

    Science.gov (United States)

    Breton, Marc D; Hinzmann, Rolf; Campos-Nañez, Enrique; Riddle, Susan; Schoemaker, Michael; Schmelzeisen-Redeker, Guenther

    2017-05-01

    Computer simulation has been shown over the past decade to be a powerful tool to study the impact of medical devices characteristics on clinical outcomes. Specifically, in type 1 diabetes (T1D), computer simulation platforms have all but replaced preclinical studies and are commonly used to study the impact of measurement errors on glycemia. We use complex mathematical models to represent the characteristics of 3 continuous glucose monitoring systems using previously acquired data. Leveraging these models within the framework of the UVa/Padova T1D simulator, we study the impact of CGM errors in 6 simulation scenarios designed to generate a wide variety of glycemic conditions. Assessment of the simulated accuracy of each different CGM systems is performed using mean absolute relative deviation (MARD) and precision absolute relative deviation (PARD). We also quantify the capacity of each system to detect hypoglycemic events. The simulated Roche CGM sensor prototype (RCGM) outperformed the 2 alternate systems (CGM-1 & CGM-2) in accuracy (MARD = 8% vs 11.4% vs 18%) and precision (PARD = 6.4% vs 9.4% vs 14.1%). These results held for all studied glucose and rate of change ranges. Moreover, it detected more than 90% of hypoglycemia, with a mean time lag less than 4 minutes (CGM-1: 86%/15 min, CGM-2: 57%/24 min). The RCGM system model led to strong performances in these simulation studies, with higher accuracy and precision than alternate systems. Its characteristics placed it firmly as a strong candidate for CGM based therapy, and should be confirmed in large clinical studies.

  13. Monthly use of a real-time continuous glucose monitoring system as an educational and motivational tool for poorly controlled type 1 diabetes adolescents.

    Science.gov (United States)

    Głowińska-Olszewska, B; Tobiaszewska, M; Łuczyński, W; Bossowski, A

    2013-01-01

    Experience with the use of real-time continuous glucose monitoring systems (RT-CGMS) in teenagers with type 1 diabetes mellitus (T1DM) is limited. We aimed to assess the possibility of glycaemic control improvement and to characterize the group of adolescents, who may gain long-term benefits from the use of the RT-CGMS. Forty T1DM patients, aged 14.6 ± 2.1 years, with diabetes duration 7.4 ± 3.6 years and initial HbA₁c 9.3 ± 1.5% were recruited. The analysis was based on one-month glucose sensors use, combined with the thorough family support. Patients were analysed in groups according to baseline HbA₁c: below and above 7.5%, and 10.0%. Comparison between patients with or without improvement in HbA₁c after 3-month follow-up was also performed. Patients' satisfaction based on the questionnaire was assessed. HbA₁c level in entire study group decreased after three months, from 9.3 ± 1.0% to 8.8 ± 1.6% (P10% did not achieve significant improvement: 11.2 ± 0.5% vs. 10.9 ± 1.1 (P=0.06). In satisfaction questionnaire the lowest scores (negative opinion) were reported by group of patients with initial HbA₁c above 10%, while the highest scores (positive opinion) were found in the group with improvement of HbA₁c after 3 month follow-up. Short-term use of CGMS RT, united with satisfaction questionnaire, performed in poorly controlled teenagers with T1DM, can be useful in defining the group of young patients, who can benefit from long-term CGMS RT use in metabolic control improvement.

  14. Cost-effectiveness of G5 Mobile continuous glucose monitoring device compared to self-monitoring of blood glucose alone for people with type 1 diabetes from the Canadian societal perspective.

    Science.gov (United States)

    Chaugule, Shraddha; Graham, Claudia

    2017-11-01

    To evaluate the cost-effectiveness of real-time continuous glucose monitoring (CGM) compared to self-monitoring of blood glucose (SMBG) alone in people with type 1 diabetes (T1DM) using multiple daily injections (MDI) from the Canadian societal perspective. The IMS CORE Diabetes Model (v.9.0) was used to assess the long-term (50 years) cost-effectiveness of real-time CGM (G5 Mobile CGM System; Dexcom, Inc., San Diego, CA) compared with SMBG alone for a cohort of adults with poorly-controlled T1DM. Treatment effects and baseline characteristics of patients were derived from the DIAMOND randomized controlled clinical trial; all other assumptions and costs were sourced from published research. The accuracy and clinical effectiveness of G5 Mobile CGM is the same as the G4 Platinum CGM used in the DIAMOND randomized clinical trial. Base case assumptions included (a) baseline HbA1c of 8.6%, (b) change in HbA1c of -1.0% for CGM users vs -0.4% for SMBG users, and (c) disutilities of -0.0142 for non-severe hypoglycemic events (NSHEs) and severe hypoglycemic events (SHEs) not requiring medical intervention, and -0.047 for SHEs requiring medical resources. Treatment costs and outcomes were discounted at 1.5% per year. The incremental cost-effectiveness ratio for the base case G5 Mobile CGM vs SMBG was $33,789 CAD/quality-adjusted life-year (QALY). Sensitivity analyses showed that base case results were most sensitive to changes in percentage reduction in hypoglycemic events and disutilities associated with hypoglycemic events. The base case results were minimally impacted by changes in baseline HbA1c level, incorporation of indirect costs, changes in the discount rate, and baseline utility of patients. The results of this analysis demonstrate that G5 Mobile CGM is cost-effective within the population of adults with T1DM using MDI, assuming a Canadian willingness-to-pay threshold of $50,000 CAD per QALY.

  15. Consideration of Insulin Pumps or Continuous Glucose Monitors by Adolescents With Type 1 Diabetes and Their Parents: Stakeholder Engagement in the Design of Web-Based Decision Aids.

    Science.gov (United States)

    Wysocki, Tim; Hirschfeld, Fiona; Miller, Louis; Izenberg, Neil; Dowshen, Steven A; Taylor, Alex; Milkes, Amy; Shinseki, Michelle T; Bejarano, Carolina; Kozikowski, Chelsea; Kowal, Karen; Starr-Ashton, Penny; Ross, Judith L; Kummer, Mark; Carakushansky, Mauri; Lyness, D'Arcy; Brinkman, William; Pierce, Jessica; Fiks, Alexander; Christofferson, Jennifer; Rafalko, Jessica; Lawson, Margaret L

    2016-08-01

    This article describes the stakeholder-driven design, development, and testing of web-based, multimedia decision aids for youth with type 1 diabetes who are considering the insulin pump or continuous glucose monitoring and their parents. This is the initial phase of work designed to develop and evaluate the efficacy of these decision aids in promoting improved decision-making engagement with use of a selected device. Qualitative interviews of 36 parents and adolescents who had previously faced these decisions and 12 health care providers defined the content, format and structure of the decision aids. Experts in children's health media helped the research team to plan, create, and refine multimedia content and its presentation. A web development firm helped organize the content into a user-friendly interface and enabled tracking of decision aid utilization. Throughout, members of the research team, adolescents, parents, and 3 expert consultants offered perspectives about the website content, structure, and function until the design was complete. With the decision aid websites completed, the next phase of the project is a randomized controlled trial of usual clinical practice alone or augmented by use of the decision aid websites. Stakeholder-driven development of multimedia, web-based decision aids requires meticulous attention to detail but can yield exceptional resources for adolescents and parents contemplating major changes to their diabetes regimens. © 2016 The Author(s).

  16. Continuous glucose monitoring with Humalog Mix 25 versus Humalog Mix 50, twice daily: A comparative pilot study -Results from the Jikei-EValuation of insulin Lispro mixture on pharmacodynamics and glycemic VariancE (J-EVOLVE study

    Directory of Open Access Journals (Sweden)

    Morimoto Aya

    2010-05-01

    Full Text Available Abstract Objective To evaluate glycemic variability associated with two different premixed insulin analogue formulations when used in a twice-daily regimen. Patients and Methods Subjects comprised type 2 diabetic patients aged 20-79 years, treated with twice daily premixed insulin or insulin analogue formulations. All subjects were hospitalized for 6 days and randomized to receive either Humalog Mix 25 (Mix 25 or Humalog Mix 50 (Mix 50. They were then crossed over to the other arm between day 3 and day 4 of the study. Continuous glucose monitoring (CGM was performed on all subjects to examine the differences in glycemic variability. Results Eleven type 2 diabetic patients were enrolled. No significant difference was found in 24-hour mean glucose values and their SDs, pre-meal glucose values, increases from pre-meal to peak glucose values, or time to peak glucose levels between either group. However, the mean glucose values observed during 0-8 hrs were significantly lower with Mix 25 compared to Mix 50 (128 vs. 147 mg/dL; p = 0.024. Conclusions The twice-daily Mix 25 regimen provided superior overnight glycemic control compared to the Mix 50 regimen in Japanese patients with type 2 diabetes. However, both twice-daily regimens with either Mix 25 or Mix 50 provided inadequate post-lunch glycemic control. Trial Registration Current Controlled Trials UMIN000001327

  17. An exploratory trial of basal and prandial insulin initiation and titration for type 2 diabetes in primary care with adjunct retrospective continuous glucose monitoring: INITIATION study.

    Science.gov (United States)

    Blackberry, Irene D; Furler, John S; Ginnivan, Louise E; Manski-Nankervis, Jo-Anne; Jenkins, Alicia; Cohen, Neale; Best, James D; Young, Doris; Liew, Danny; Ward, Glenn; O'Neal, David N

    2014-11-01

    To evaluate basal and prandial insulin initiation and titration in people with type 2 diabetes mellitus (T2DM) in primary care and to explore the feasibility of retrospective-continuous glucose monitoring (r-CGM) in guiding insulin dosing. The new model of care features General Practitioners (GPs) and Practice Nurses (PNs) working in an expanded role, with Credentialed Diabetes Educator - Registered Nurse (CDE-RN) support. Insulin-naïve T2DM patients (HbA1c >7.5% [>58 mmol/mol] despite maximal oral therapy) from 22 general practices in Victoria, Australia commenced insulin glargine, with glulisine added as required. Each was randomised to receive r-CGM or self-monitoring of blood glucose (SMBG). Glycaemic control (HbA1c) was benchmarked against specialist ambulatory patients referred for insulin initiation. Ninety-two patients mean age (range) 59 (28-77) years; 40% female; mean (SD) diabetes duration 10.5 (6.1) years participated. HbA1c decreased from (median (IQR)) 9.9 (8.8, 11.2)%; 85 (73, 99) mmol/mol to 7.3 (6.9, 7.8)%; 56 (52, 62) mmol/mol at 24 weeks (p < 0.0001). Comparing r-CGM (n = 46) with SMBG (n = 42), there were no differences in major hypoglycaemia (p=0.17) or ΔHbA1c (p = 0.31). More r-CGM than SMBG participants commenced glulisine (26/48 vs. 7/44; p < 0.001). Results were comparable to 82 benchmark patients, with similar low rates of major hypoglycaemia (2/89 vs. 0/82; p = 0.17) and less loss to follow up in the INITIATION group (3/92 vs. 14/82; p = 0.002). Insulin initiation and titration for T2DM patients in primary care was safe and improved HbA1c with low rates of major hypoglycaemia. CDE-RNs were effective in a new consultant role. r-CGM use in primary care was feasible and enhanced post-prandial hyperglycaemia recognition. Trial registration ACTRN12610000797077. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Integration and Evaluation of a Position Sensor with Continuous Read-Out for use with the Environmental Measurement-While-Drilling Gamma Ray Spectrometer System

    International Nuclear Information System (INIS)

    Lockwood, G.J.; Normann, R.A.; Selph, M.M.; Williams, C.V.

    1999-01-01

    The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site (SRS) F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled waste retention basin. These boreholes passed near previously sampled locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRS system during drilling were compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples. The demonstration of the EMWD-GRS was a complete success. The results show general agreement between the soil sampling and EMWD-GRS techniques for CS-137. It was recognized that the EMWD-GRS tool would better satisfy our customers' needs if the instrument location could be continuously monitored. During the demonstration at SRS, an electromagnetic beacon with a walkover monitor (Subsitereg s ign) was used to measure bit location at depth. To use a beacon locator drilling must be stopped, thus it is normally only used when a new section of pipe was added. The location of contamination could only be estimated based on the position of the EMED-GRS package and the distance between locator beacon readings. A continuous location system that would allow us to know the location of each spectrum as it is obtained is needed

  19. Current concepts in blood glucose monitoring

    OpenAIRE

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on t...

  20. Teaching Reading

    Science.gov (United States)

    Day, Richard R.

    2013-01-01

    "Teaching Reading" uncovers the interactive processes that happen when people learn to read and translates them into a comprehensive easy-to-follow guide on how to teach reading. Richard Day's revelations on the nature of reading, reading strategies, reading fluency, reading comprehension, and reading objectives make fascinating…

  1. A Qualitative Analysis of Real-Time Continuous Glucose Monitoring Data Sharing with Care Partners: To Share or Not to Share?

    Science.gov (United States)

    Litchman, Michelle L; Allen, Nancy A; Colicchio, Vanessa D; Wawrzynski, Sarah E; Sparling, Kerri M; Hendricks, Krissa L; Berg, Cynthia A

    2018-01-01

    Little research exists regarding how real-time continuous glucose monitoring (RT-CGM) data sharing plays a role in the relationship between patients and their care partners. To (1) identify the benefits and challenges related to RT-CGM data sharing from the patient and care partner perspective and (2) to explore the number and type of individuals who share and follow RT-CGM data. This qualitative content analysis was conducted by examining publicly available blogs focused on RT-CGM and data sharing. A thematic analysis of blogs and associated comments was conducted. A systematic appraisal of personal blogs examined 39 blogs with 206 corresponding comments. The results of the study provided insight about the benefits and challenges related to individuals with diabetes sharing their RT-CGM data with a care partner(s). The analysis resulted in three themes: (1) RT-CGM data sharing enhances feelings of safety, (2) the need to communicate boundaries to avoid judgment, and (3) choice about sharing and following RT-CGM data. RT-CGM data sharing occurred within dyads (n = 46), triads (n = 15), and tetrads (n = 2). Adults and children with type 1 diabetes and their care partners are empowered by the ability to share and follow RT-CGM data. Our findings suggest that RT-CGM data sharing between an individual with diabetes and their care partner can complicate relationships. Healthcare providers need to engage patients and care partners in discussions about best practices related to RT-CGM sharing and following to avoid frustrations within the relationship.

  2. Integrated sensor-augmented pump therapy systems [the MiniMed® Paradigm™ Veo system and the Vibe™ and G4® PLATINUM CGM (continuous glucose monitoring) system] for managing blood glucose levels in type 1 diabetes: A systematic review and economic evaluation

    NARCIS (Netherlands)

    R. Riemsma (Rob); I. Corro Ramos (Isaac); R. Birnie (Richard); N. Büyükkaramikli (Nasuh); N. Armstrong (Nigel); S. Ryder; S. Duffy (Steven); G. Worthy (Gill); M.J. Al (Maiwenn); J. Severens (Johan); J. Kleijnen (Jos)

    2016-01-01

    textabstractBackground: In recent years, meters for continuous monitoring of interstitial fluid glucose have been introduced to help people with type 1 diabetes mellitus (T1DM) to achieve better control of their disease. Objective: The objective of this project was to summarise the evidence on the

  3. Nanomaterials in glucose sensing

    CERN Document Server

    Burugapalli, Krishna

    2013-01-01

    The smartness of nano-materials is attributed to their nanoscale and subsequently unique physicochemical properties and their use in glucose sensing has been aimed at improving performance, reducing cost and miniaturizing the sensor and its associated instrumentation. So far, portable (handheld) glucose analysers were introduced for hospital wards, emergency rooms and physicians' offices; single-use strip systems achieved nanolitre sampling for painless and accurate home glucose monitoring; advanced continuous monitoring devices having 2 to 7 days operating life are in clinical and home use; and continued research efforts are being made to develop and introduce increasingly advanced glucose monitoring systems for health as well as food, biotechnology, cell and tissue culture industries. Nanomaterials have touched every aspect of biosensor design and this chapter reviews their role in the development of advanced technologies for glucose sensing, and especially for diabetes. Research shows that overall, nanomat...

  4. Intermittent v. continuous energy restriction: differential effects on postprandial glucose and lipid metabolism following matched weight loss in overweight/obese participants.

    Science.gov (United States)

    Antoni, Rona; Johnston, Kelly L; Collins, Adam L; Robertson, M Denise

    2018-03-01

    The intermittent energy restriction (IER) approach to weight loss involves short periods of substantial (>70 %) energy restriction (ER) interspersed with normal eating. Studies to date comparing IER to continuous energy restriction (CER) have predominantly measured fasting indices of cardiometabolic risk. This study aimed to compare the effects of IER and CER on postprandial glucose and lipid metabolism following matched weight loss. In all, twenty-seven (thirteen male) overweight/obese participants (46 (sem 3) years, 30·1 (sem 1·0) kg/m2) who were randomised to either an IER intervention (2638 kJ for 2 d/week with an overall ER of 22 (sem 0·3) %, n 15) or a CER intervention (2510 kJ below requirements with overall ER of 23 (sem 0·8) %) completed the study. Postprandial responses to a test meal (over 360 min) and changes in anthropometry (fat mass, fat-free mass, circumferences) were assessed at baseline and upon attainment of 5 % weight loss, following a 7-d period of weight stabilisation. The study found no statistically significant difference in the time to attain a 5 % weight loss between groups (median 59 d (interquartile range (IQR) 41-80) and 73 d (IQR 48-128), respectively, P=0·246), or in body composition (P≥0·437). For postprandial measures, neither diet significantly altered glycaemia (P=0·266), whereas insulinaemia was reduced comparatively (P=0·903). The reduction in C-peptide tended (P=0·057) to be greater following IER (309 128 (sem23 268) to 247781 (sem20 709) pmol×360 min/l) v. CER (297 204 (sem25 112) to 301 655 (sem32 714) pmol×360 min/l). The relative reduction in TAG responses was greater (P=0·045) following IER (106 (sem30) to 68 (sem 15) mmol×360 min/l) compared with CER (117 (sem 43) to 130 (sem 31) mmol×360 min/l). In conclusion, these preliminary findings highlight underlying differences between IER and CER, including a superiority of IER in reducing postprandial lipaemia, which now warrant targeted mechanistic evaluation

  5. Novel Non-Intrusive Trans-Dermal Remote Wireless Micro-Fluidic Monitoring System Applied to Continuous Glucose and Lactate Assays for Casualty Care and Combat Readiness Assessment

    Science.gov (United States)

    2004-09-01

    identification of the lettered features. 2.2 BFIT Sampling Chip The BFIT sampling chip is a flexible patch-like chip with a multilayer polymeric metal...PPy) and glucose oxidase (GOD). The BFIT fabrication process uses SU8 as a principal structural material consisting of five steps (Figure 2). This...process is a subset of an earlier technology developed for the polymer material PDMS.11,12,13,14,15 The first step was the deposition of a Teflon

  6. Continuous insulin administration via complex central venous catheter infusion tubing is another risk factor for blood glucose imbalance. A retrospective study.

    Science.gov (United States)

    Maury, Eric; Vitry, Paola; Galbois, Arnauld; Ait-Oufella, Hafid; Baudel, Jean-Luc; Guidet, Bertrand; Offenstadt, Georges

    2012-06-14

    We assessed the potential impact of infusion tubing on blood glucose imbalance in ICU patients given intensive insulin therapy (IIT). We compared the incidence of blood glucose imbalance in patients equipped, in a nonrandomized fashion, with either conventional tubing or with a multiport infusion device. We retrospectively analyzed the nursing files of 35 patients given IIT through the distal line of a double-lumen central venous catheter. A total of 1389 hours of IIT were analyzed for occurrence of hypoglycemic events [defined as arterial blood glucose below 90 mg/dL requiring discontinuation of insulin]. Twenty-one hypoglycemic events were noted (density of incidence 15 for 1000 hours of ITT). In 17 of these 21 events (81%), medication had been administered during the previous hour through the line connected to the distal lumen of the catheter. Conventional tubing use was associated with a higher density of incidence of hypoglycemic events than multiport infusion device use (23 vs. 2 for 1,000 hours of IIT; rate ratio = 11.5; 95% confidence interval, 2.71-48.8; p tubing carrying other medications can lead to the delivery of significant amounts of unscheduled products. Hypoglycaemia observed during IIT could be related to this phenomenon. The use of a multiport infusion device with a limited dead volume could limit hypoglycemia in patients on IIT.

  7. Reading faster

    Directory of Open Access Journals (Sweden)

    Paul Nation

    2009-12-01

    Full Text Available This article describes the visual nature of the reading process as it relates to reading speed. It points out that there is a physical limit on normal reading speed and beyond this limit the reading process will be different from normal reading where almost every word is attended to. The article describes a range of activities for developing reading fluency, and suggests how the development of fluency can become part of a reading programme.

  8. Current concepts in blood glucose monitoring.

    Science.gov (United States)

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-12-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus.

  9. Current concepts in blood glucose monitoring

    Science.gov (United States)

    Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini

    2013-01-01

    Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus. PMID:24910827

  10. Current concepts in blood glucose monitoring

    Directory of Open Access Journals (Sweden)

    Kranti Shreesh Khadilkar

    2013-01-01

    Full Text Available Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG and continuous glucose monitoring system (CGMS. It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus.

  11. Mentoring Literacy Professionals: Continuing the Spirit of CRA/ALER after 50 Years. The Thirty-First Yearbook: A Doubled Peer Reviewed Publication of the College Reading Association

    Science.gov (United States)

    Szabo, Susan, Ed.; Sampson, Mary Beth, Ed.; Foote, Martha M., Ed.; Falk-Ross, Francine, Ed.

    2010-01-01

    This volume is a milestone year for the Yearbook, the conference, and the College Reading Association (CRA). At this conference, CRA celebrated its 50th year. The title of this thirty-first yearbook mirrors the theme of the 2008 conference--"Mentoring Literacy Professionals for 50 Years." The title "Mentoring Literacy Professionals:…

  12. Long-term blood glucose monitoring with implanted telemetry device in conscious and stress-free cynomolgus monkeys.

    Science.gov (United States)

    Wang, B; Sun, G; Qiao, W; Liu, Y; Qiao, J; Ye, W; Wang, H; Wang, X; Lindquist, R; Wang, Y; Xiao, Y-F

    2017-09-01

    Continuous blood glucose monitoring, especially long-term and remote, in diabetic patients or research is very challenging. Nonhuman primate (NHP) is an excellent model for metabolic research, because NHPs can naturally develop Type 2 diabetes mellitus (T2DM) similarly to humans. This study was to investigate blood glucose changes in conscious, moving-free cynomolgus monkeys (Macaca fascicularis) during circadian, meal, stress and drug exposure. Blood glucose, body temperature and physical activities were continuously and simultaneously recorded by implanted HD-XG telemetry device for up to 10 weeks. Blood glucose circadian changes in normoglycemic monkeys significantly differed from that in diabetic animals. Postprandial glucose increase was more obvious after afternoon feeding. Moving a monkey from its housing cage to monkey chair increased blood glucose by 30% in both normoglycemic and diabetic monkeys. Such increase in blood glucose declined to the pre-procedure level in 30 min in normoglycemic animals and >2 h in diabetic monkeys. Oral gavage procedure alone caused hyperglycemia in both normoglycemic and diabetic monkeys. Intravenous injection with the stress hormones, angiotensin II (2 μg/kg) or norepinephrine (0.4 μg/kg), also increased blood glucose level by 30%. The glucose levels measured by the telemetry system correlated significantly well with glucometer readings during glucose tolerance tests (ivGTT or oGTT), insulin tolerance test (ITT), graded glucose infusion (GGI) and clamp. Our data demonstrate that the real-time telemetry method is reliable for monitoring blood glucose remotely and continuously in conscious, stress-free, and moving-free NHPs with the advantages highly valuable to diabetes research and drug discovery.

  13. One-step simultaneous differential scanning calorimetry-FTIR microspectroscopy to quickly detect continuous pathways in the solid-state glucose/asparagine Maillard reaction.

    Science.gov (United States)

    Hwang, Deng-Fwu; Hsieh, Tzu-Feng; Lin, Shan-Yang

    2013-01-01

    The stepwise reaction pathway of the solid-state Maillard reaction between glucose (Glc) and asparagine (Asn) was investigated using simultaneous differential scanning calorimetry (DSC)-FTIR microspectroscopy. The color change and FTIR spectra of Glc-Asn physical mixtures (molar ratio = 1:1) preheated to different temperatures followed by cooling were also examined. The successive reaction products such as Schiff base intermediate, Amadori product, and decarboxylated Amadori product in the solid-state Glc-Asn Maillard reaction were first simultaneously evidenced by this unique DSC-FTIR microspectroscopy. The color changed from white to yellow-brown to dark brown, and appearance of new IR peaks confirmed the formation of Maillard reaction products. The present study clearly indicates that this unique DSC-FTIR technique not only accelerates but also detects precursors and products of the Maillard reaction in real time.

  14. STUDENTS’ READING PRACTICES AND ENVIRONMENTS

    Directory of Open Access Journals (Sweden)

    Aiza Johari

    2013-07-01

    Full Text Available Abstract: The challenges of reading are indeed apparent in most teaching and learning processes in ESL classrooms. As a result, this study is conducted to resolve the issues of students who seem to find reading to be unbearable. Many of them have limited ability to read well and hence, possess insufficient reading habits to become competent readers, particularly out-of-school context. Besides, poor home literacy environments also contribute to their shortcomings in reading. The main objectives of this study are to identify the students’ reasons for reading as well as to find out their home reading environments (reading backgrounds and habits; reading attitudes and motivation; reading exposure and supports. To identify these, questionnaires were distributed to 120 secondary school students (Form 4: 16 years old from one of the urban schools in Sarawak, Malaysia. The findings indicate that the students read to gain information and knowledge though many chose reading as a hobby as their last choice in explaining their motives of reading. Besides, they preferred non-academic reading materials, mainly lighter forms reading materials such as comics, story books and magazines. Though the students acknowledged the importance of reading in their daily lives, their average reading habits, attitude, motivation, exposure and support within the home domain had suggested otherwise. They mainly read for instrumental purposes while reading for pleasure seemed not to be given priority. Besides, the respondents acknowledge that their parents and themselves did not read much at home. As an implication, it is vital for students to improve their reading perceptions, abilities and practices to achieve personal, societal and national progress. On a final note, parents’ early and continuous efforts to be involved in their children’s literacy events in an out-of-school context are believed to be vital to inculcate positive reading environments, habits and culture

  15. Reading: Time

    NARCIS (Netherlands)

    Annemarie Wennekers; Frank Huysmans; Jos de Haan

    2018-01-01

    Original title: Lees:Tijd The amount of time that Dutch people spend reading has been declining steadily since the 1950s. This decline in reading time contrasts starkly with the positive personal and social benefits that can be derived from reading, according to lots of research. The Reading:

  16. Reading Comics

    Science.gov (United States)

    Tilley, Carol L.

    2008-01-01

    Many adults, even librarians who willingly add comics to their collections, often dismiss the importance of comics. Compared to reading "real" books, reading comics appears to be a simple task and compared to reading no books, reading comics might be preferable. After all, comics do have words, but the plentiful pictures seem to carry most of the…

  17. Glucose allostasis

    DEFF Research Database (Denmark)

    Stumvoll, Michael; Tataranni, P Antonio; Stefan, Norbert

    2003-01-01

    individuals with normal glucose tolerance, normoglycemia can always be maintained by compensatorily increasing AIR in response to decreasing M (and vice versa). This has been mathematically described by the hyperbolic relationship between AIR and M and referred to as glucose homeostasis, with glucose......In many organisms, normoglycemia is achieved by a tight coupling of nutrient-stimulated insulin secretion in the pancreatic beta-cell (acute insulin response [AIR]) and the metabolic action of insulin to stimulate glucose disposal (insulin action [M]). It is widely accepted that in healthy...... concentration assumed to remain constant along the hyperbola. Conceivably, glucose is one of the signals stimulating AIR in response to decreasing M. Hypothetically, as with any normally functioning feed-forward system, AIR should not fully compensate for worsening M, since this would remove the stimulus...

  18. Calculating the Mean Amplitude of Glycemic Excursions from Continuous Glucose Data Using an Open-Code Programmable Algorithm Based on the Integer Nonlinear Method.

    Science.gov (United States)

    Yu, Xuefei; Lin, Liangzhuo; Shen, Jie; Chen, Zhi; Jian, Jun; Li, Bin; Xin, Sherman Xuegang

    2018-01-01

    The mean amplitude of glycemic excursions (MAGE) is an essential index for glycemic variability assessment, which is treated as a key reference for blood glucose controlling at clinic. However, the traditional "ruler and pencil" manual method for the calculation of MAGE is time-consuming and prone to error due to the huge data size, making the development of robust computer-aided program an urgent requirement. Although several software products are available instead of manual calculation, poor agreement among them is reported. Therefore, more studies are required in this field. In this paper, we developed a mathematical algorithm based on integer nonlinear programming. Following the proposed mathematical method, an open-code computer program named MAGECAA v1.0 was developed and validated. The results of the statistical analysis indicated that the developed program was robust compared to the manual method. The agreement among the developed program and currently available popular software is satisfied, indicating that the worry about the disagreement among different software products is not necessary. The open-code programmable algorithm is an extra resource for those peers who are interested in the related study on methodology in the future.

  19. Acurácia, utilidade e complicações da monitorização subcutânea contínua da glicose (CGMS em pacientes pediátricos com diabetes tipo 1 Accuracy, utility and complications of continuous glucose monitoring system (CGMS in pediatric patients with type 1 diabetes

    Directory of Open Access Journals (Sweden)

    Frederico F. R. Maia

    2005-08-01

    Full Text Available OBJETIVO: Avaliar a acurácia, utilidade e complicações da monitorização subcutânea contínua da glicemia em crianças e adolescentes com diabetes melito tipo 1 (DM1. MÉTODOS: Foram estudados retrospectivamente 16 pacientes (16,12±4,41 anos, submetidos à monitorização subcutânea contínua da glicemia (Medtronic; Northridge, CA, EUA por 72 horas. Foram analisados os valores de glicemia capilar média e pelo sensor monitorização subcutânea contínua da glicemia; excursões glicêmicas (monitorização subcutânea contínua da glicemia versus. glicemia capilar; hiperglicemia pós-prandial (OBJECTIVE: To evaluate the accuracy, utility and complications of continuous glucose monitoring system in children and adolescents with type 1 diabetes. METHODS: This retrospective study assessed 16 type 1 diabetic patients (16.12±4.41 years submitted to continuous glucose monitoring system (Medtronic; Northridge, CA for 72 hours. The following parameters were analyzed: mean capillary glucose level and mean glucose value measured by the continuous glucose monitoring system; glucose excursions (continuous glucose monitoring system vs. capillary glucose measurement, postprandial hyperglycemia (NR < 140 mg/dl, nocturnal hypoglycemia, complications (trauma, local infection, disconnection and therapeutic management after continuous glucose monitoring. A1c levels were measured at the beginning and after 3 months of the study. RESULTS: The mean capillary glucose values were 214.3±66.5 mg/dl vs. 207.6±54.6 mg/dl by continuous glucose monitoring system, with a significant correlation (p = 0.001. The correlation coefficient and mean absolute error were 0.86±0.21 and 12.6% of the median, respectively. The continuous glucose monitoring system was significantly more efficient in detecting glucose excursion than fingerstick capillary blood sampling (p = 0.04; W = 74, and postprandial hyperglycemia was identified in 60% of type 1 diabetic patients with a

  20. Effects of High-Intensity Interval Exercise versus Moderate Continuous Exercise on Glucose Homeostasis and Hormone Response in Patients with Type 1 Diabetes Mellitus Using Novel Ultra-Long-Acting Insulin.

    Science.gov (United States)

    Moser, Othmar; Tschakert, Gerhard; Mueller, Alexander; Groeschl, Werner; Pieber, Thomas R; Obermayer-Pietsch, Barbara; Koehler, Gerd; Hofmann, Peter

    2015-01-01

    We investigated blood glucose (BG) and hormone response to aerobic high-intensity interval exercise (HIIE) and moderate continuous exercise (CON) matched for mean load and duration in type 1 diabetes mellitus (T1DM). Seven trained male subjects with T1DM performed a maximal incremental exercise test and HIIE and CON at 3 different mean intensities below (A) and above (B) the first lactate turn point and below the second lactate turn point (C) on a cycle ergometer. Subjects were adjusted to ultra-long-acting insulin Degludec (Tresiba/ Novo Nordisk, Denmark). Before exercise, standardized meals were administered, and short-acting insulin dose was reduced by 25% (A), 50% (B), and 75% (C) dependent on mean exercise intensity. During exercise, BG, adrenaline, noradrenaline, dopamine, cortisol, glucagon, and insulin-like growth factor-1, blood lactate, heart rate, and gas exchange variables were measured. For 24 h after exercise, interstitial glucose was measured by continuous glucose monitoring system. BG decrease during HIIE was significantly smaller for B (p = 0.024) and tended to be smaller for A and C compared to CON. No differences were found for post-exercise interstitial glucose, acute hormone response, and carbohydrate utilization between HIIE and CON for A, B, and C. In HIIE, blood lactate for A (p = 0.006) and B (p = 0.004) and respiratory exchange ratio for A (p = 0.003) and B (p = 0.003) were significantly higher compared to CON but not for C. Hypoglycemia did not occur during or after HIIE and CON when using ultra-long-acting insulin and applying our methodological approach for exercise prescription. HIIE led to a smaller BG decrease compared to CON, although both exercises modes were matched for mean load and duration, even despite markedly higher peak workloads applied in HIIE. Therefore, HIIE and CON could be safely performed in T1DM. ClinicalTrials.gov NCT02075567 http://www.clinicaltrials.gov/ct2/show/NCT02075567.

  1. Effects of High-Intensity Interval Exercise versus Moderate Continuous Exercise on Glucose Homeostasis and Hormone Response in Patients with Type 1 Diabetes Mellitus Using Novel Ultra-Long-Acting Insulin.

    Directory of Open Access Journals (Sweden)

    Othmar Moser

    Full Text Available We investigated blood glucose (BG and hormone response to aerobic high-intensity interval exercise (HIIE and moderate continuous exercise (CON matched for mean load and duration in type 1 diabetes mellitus (T1DM.Seven trained male subjects with T1DM performed a maximal incremental exercise test and HIIE and CON at 3 different mean intensities below (A and above (B the first lactate turn point and below the second lactate turn point (C on a cycle ergometer. Subjects were adjusted to ultra-long-acting insulin Degludec (Tresiba/ Novo Nordisk, Denmark. Before exercise, standardized meals were administered, and short-acting insulin dose was reduced by 25% (A, 50% (B, and 75% (C dependent on mean exercise intensity. During exercise, BG, adrenaline, noradrenaline, dopamine, cortisol, glucagon, and insulin-like growth factor-1, blood lactate, heart rate, and gas exchange variables were measured. For 24 h after exercise, interstitial glucose was measured by continuous glucose monitoring system.BG decrease during HIIE was significantly smaller for B (p = 0.024 and tended to be smaller for A and C compared to CON. No differences were found for post-exercise interstitial glucose, acute hormone response, and carbohydrate utilization between HIIE and CON for A, B, and C. In HIIE, blood lactate for A (p = 0.006 and B (p = 0.004 and respiratory exchange ratio for A (p = 0.003 and B (p = 0.003 were significantly higher compared to CON but not for C.Hypoglycemia did not occur during or after HIIE and CON when using ultra-long-acting insulin and applying our methodological approach for exercise prescription. HIIE led to a smaller BG decrease compared to CON, although both exercises modes were matched for mean load and duration, even despite markedly higher peak workloads applied in HIIE. Therefore, HIIE and CON could be safely performed in T1DM.ClinicalTrials.gov NCT02075567 http://www.clinicaltrials.gov/ct2/show/NCT02075567.

  2. Effect of prandial treatment timing adjustment, based on continuous glucose monitoring, in patients with type 2 diabetes uncontrolled with once-daily basal insulin: A randomized, phase IV study.

    Science.gov (United States)

    Ilany, Jacob; Bhandari, Hamad; Nabriski, Dan; Toledano, Yoel; Konvalina, Noa; Cohen, Ohad

    2018-05-01

    To evaluate the glycaemic control achieved by prandial once-daily insulin glulisine injection timing adjustment, based on a continuous glucose monitoring sensor, in comparison to once-daily insulin glulisine injection before breakfast in patients with type 2 diabetes who are uncontrolled with once-daily basal insulin glargine. This was a 24-week open-label, randomized, controlled, multicentre trial. At the end of an 8-week period of basal insulin optimization, patients with HbA1c ≥ 7.5% and FPG sensor) or arm B (sensor) to receive 16-week intensified prandial glulisine treatment. Patients in arm A received pre-breakfast glulisine, and patients in arm B received glulisine before the meal with the highest glucose elevation based on sensor data. The primary outcome was mean HbA1c at week 24 and secondary outcomes included rates of hypoglycaemic events and insulin dosage. A total of 121 patients were randomized to arm A (n = 61) or arm B (n = 60). There was no difference in mean HbA1c at week 24 between arms A and B (8.5% ± 1.2% vs 8.4% ± 1.0%; P = .66). The prandial insulin glulisine dosage for arm A and arm B was 9.3 and 10.1 units, respectively (P = .39). The frequency of hypoglycaemic events did not differ between study arms (36.1% vs 51.7%; P = .08). Using a CGM sensor to identify the meal with the highest glucose excursion and adjusting the timing of prandial insulin treatment did not show any advantage in terms of glycaemic control or safety in our patients. © 2018 The Authors. Diabetes, Obesity and Metabolism published by John Wiley & Sons Ltd.

  3. Screening of gingival crevicular blood glucose and capillary finger blood glucose in the diagnosis of diabetes

    Directory of Open Access Journals (Sweden)

    Alka S Waghmare

    2011-01-01

    Full Text Available Aim: The study aimed at obtaining glucose readings using gingival crevicular blood (GCB to screen for undiagnosed diabetes during routine dental visits. Materials and Methods: The present study included 50 patients who were divided into two groups, i.e. Group A and Group B, based on bleeding on probing at the site of collection of GCB. Group A participants had blood collected from sites having adequate bleeding on probing, whereas Group B participants had blood collected from sites with little bleeding on probing. GCB and capillary finger-stick blood (CFB] glucose readings were obtained using a self-monitoring glucometer. Statistical Analysis: Correlations between both the samples were done using Pearson′s correlation. Results: Group A patients′ correlations between GCB and CFB glucose readings were high, whereas in Group B patients, correlations between glucose readings were low. Conclusion: GCB can be an excellent source for screening diabetes during routine dental visits.

  4. A randomized controlled trial to compare the effects of sulphonylurea gliclazide MR (modified release) and the DPP-4 inhibitor vildagliptin on glycemic variability and control measured by continuous glucose monitoring (CGM) in Brazilian women with type 2 diabetes.

    Science.gov (United States)

    Vianna, Andre Gustavo Daher; Lacerda, Claudio Silva; Pechmann, Luciana Muniz; Polesel, Michelle Garcia; Marino, Emerson Cestari; Faria-Neto, Jose Rocha

    2018-05-01

    This study aims to evaluate whether there is a difference between the effects of vildagliptin and gliclazide MR (modified release) on glycemic variability (GV) in women with type 2 diabetes (T2DM) as evaluated by continuous glucose monitoring (CGM). An open-label, randomized study was conducted in T2DM women on steady-dose metformin monotherapy which were treated with 50 mg vildagliptin twice daily or 60-120 mg of gliclazide MR once daily. CGM and GV indices calculation were performed at baseline and after 24 weeks. In total, 42 patients (age: 61.9 ± 5.9 years, baseline glycated hemoglobin (HbA1c): 7.3 ± 0.56) were selected and 37 completed the 24-week protocol. Vildagliptin and gliclazide MR reduced GV, as measured by the mean amplitude of glycemic excursions (MAGE, p = 0.007 and 0.034, respectively). The difference between the groups did not reach statistical significance. Vildagliptin also significantly decreased the standard deviation of the mean glucose (SD) and the mean of the daily differences (MODD) (p = 0.007 and 0.030). Vildagliptin and gliclazide MR similarly reduced the MAGE in women with T2DM after 24 weeks of treatment. Further studies are required to attest differences between vildagliptin and gliclazide MR regarding glycemic variability. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Multicultural Reading

    Science.gov (United States)

    Veltze, Linda

    2004-01-01

    Multicultural reading advocates believe in the power of literature to transform and to change people's lives. They take seriously the arguments that racism and prejudice can be lessened through multicultural reading, and also that children from undervalued societal groups who read books that depict people like themselves in a positive light will…

  6. Assessment of time to glucose peak during an oral glucose tolerance test

    DEFF Research Database (Denmark)

    Hulman, Adam; Witte, Daniel R; Vistisen, Dorte

    2017-01-01

    We read with interest the article from Chung et al. on the association between time to glucose peak and prediabetes.(1) We agree with the authors in that the morphology of the glucose curve is worth investigating as an additional indicator of prediabetes and diabetes risk. This is a rather well...

  7. Acute blood glucose, cardiovascular and exaggerated responses to HIIT and moderate-intensity continuous training in men with type 2 diabetes mellitus.

    Science.gov (United States)

    Wormgoor, Shohn G; Dalleck, Lance C; Zinn, Caryn; Harris, Nigel K

    2018-01-01

    Optimizing exercise-induced physiological responses without increasing the risk of negative exaggerated responses is an important aspect of exercise prescription for people with type 2 diabetes mellitus (T2DM). However, knowledge of acute responses, including exaggerated responses, of different training modalities is limited. The aim of the study was to compare acute physiological responses of moderate-intensity continuous training (MICT) and high-intensity interval training (HIIT) in T2DM. Baseline data were used to randomly assign male participants into supervised training groups for a 12-week intervention. During week 7, participants trialed either a fully progressed MICT (N.=11) or HIIT (N.=11) (combined with resistance training) session. The MICT included 26 minutes at 55% estimated maximum workload (eWLmax) while the HIIT included twelve 1-minute bouts at 95% eWLmax interspersed with 1-minute bouts at 40% eWLmax. While energy expenditure and peak systolic and diastolic blood pressure responses were similar between groups (P=0.47, P=0.71, P=0.56, respectively), peak heart rate, workload and perceived exertion were higher in the HIIT group (P=0.04, PHIIT (36%) participants. While structured MICT and HIIT sessions resulted in comparable acute physiological responses, the individual variations and exaggerated responses, even after preparatory training, necessitated precautionary respite in T2DM men.

  8. Single, community-based blood glucose readings may be a viable alternative for community surveillance of HbA1c and poor glycaemic control in people with known diabetes in resource-poor settings

    Directory of Open Access Journals (Sweden)

    Daniel D. Reidpath

    2016-08-01

    Full Text Available Background: The term HbA1c (glycated haemoglobin is commonly used in relation to diabetes mellitus. The measure gives an indication of the average blood sugar levels over a period of weeks or months prior to testing. For most low- and middle-income countries HbA1c measurement in community surveillance is prohibitively expensive. A question arises about the possibility of using a single blood glucose measure for estimating HbA1c and therefore identifying poor glycaemic control in resource-poor settings. Design: Using data from the 2011–2012 US National Health and Nutrition Examination Surveys, we examined the relationship between HbA1c and a single fasting measure of blood glucose in a non-clinical population of people with known diabetes (n=333. A linear equation for estimating HbA1c from blood glucose was developed. Appropriate blood glucose cut-off values were set for poor glycaemic control (HbA1c≥69.4 mmol/mol. Results: The HbA1c and blood glucose measures were well correlated (r=0.7. Three blood glucose cut-off values were considered for classifying poor glycaemic control: 8.0, 8.9, and 11.4 mmol/L. A blood glucose of 11.4 had a specificity of 1, but poor sensitivity (0.37; 8.9 had high specificity (0.94 and moderate sensitivity (0.7; 8.0 was associated with good specificity (0.81 and sensitivity (0.75. Conclusions: Where HbA1c measurement is too expensive for community surveillance, a single blood glucose measure may be a reasonable alternative. Generalising the specific results from these US data to low resource settings may not be appropriate, but the general approach is worthy of further investigation.

  9. Integration and evaluation of a position sensor with continuous read-out for use with the Environmental Measurement-While-Drilling Gamma Ray Spectrometer system

    International Nuclear Information System (INIS)

    Normann, R.A.; Lockwood, G.J.; Williams, C.V.; Selph, M.M.

    1998-02-01

    The Environmental Measurement-While-Drilling-Gamma Ray Spectrometer (EMWD-GRS) system represents an innovative blend of new and existing technology that provides real-time environmental and drill bit data during drilling operations. The EMWD-GRS technology was demonstrated at Savannah River Site (SRS) F-Area Retention Basin. The EMWD-GRS technology demonstration consisted of continuously monitoring for gamma-radiation-producing contamination while drilling two horizontal boreholes below the backfilled waste retention basin. These boreholes passed near previously sampled locations where concentrations of contaminant levels of cesium had been measured. Contaminant levels continuously recorded by the EMWD-GRS system during drilling were compared to contaminant levels previously determined through quantitative laboratory analysis of soil samples. The results show general agreement between the soil sampling and EMWD-GRS techniques for Cs-137. The EMWD-GRS system has been improved by the integration of an orientation sensor package for position sensing (PS) (EMWD-GRS/PS). This added feature gives the capability of calculating position, which is tied directly to EMWD-GRS sensor data obtained while drilling. The EMWD-GRS/PS system is described and the results of the field tests are presented

  10. Predicting Plasma Glucose From Interstitial Glucose Observations Using Bayesian Methods

    DEFF Research Database (Denmark)

    Hansen, Alexander Hildenbrand; Duun-Henriksen, Anne Katrine; Juhl, Rune

    2014-01-01

    One way of constructing a control algorithm for an artificial pancreas is to identify a model capable of predicting plasma glucose (PG) from interstitial glucose (IG) observations. Stochastic differential equations (SDEs) make it possible to account both for the unknown influence of the continuous...... glucose monitor (CGM) and for unknown physiological influences. Combined with prior knowledge about the measurement devices, this approach can be used to obtain a robust predictive model. A stochastic-differential-equation-based gray box (SDE-GB) model is formulated on the basis of an identifiable...

  11. Glucose sensing issues for the artificial pancreas

    NARCIS (Netherlands)

    DeVries, J. Hans

    2008-01-01

    The first retrospective continuous glucose monitor entered the market in 1999. Now that this tool gives online data, the question arises whether it is ready to be incorporated into a closed-loop system. The author discusses the following questions: (1) Is the accuracy of current continuous glucose

  12. Reading Evaluation

    Science.gov (United States)

    Fagan, W. T.

    1978-01-01

    The Canadian Institute for Research in Behavioral and Social Sciences of Calgary was awarded a contract by the Provincial Government of Alberta to assess student skills and knowledge in reading and written composition. Here evaluation is defined and the use of standardized and criterion referenced tests for evaluating reading performance are…

  13. I read, you read, we read: the history of reading in Slovenia

    Directory of Open Access Journals (Sweden)

    Anja Dular

    2013-03-01

    Full Text Available ABSTRACTPurpose: The aim of the article is to research reading habits in Slovenia in the period between 16th and 19th century and to find similarities with Austria and other European countries of that time.Methodology/approach: For the purpose of the analysis different resources were used – study books, catechisms, prayer books and manuals. We were focused on introductions in which readers are advised how to read, explaining to whom the work is intended and emphasizing the importance of meditation on the texts.Results: Historically the laud reading was prefered, as to continue the folk tradition. However, the 16th century texts were transmitted by women while the folk tradition was narrated by males. In the 18th century the higher level of literacy and greater book production and availability caused that the books were not a privilege of a few. At that time more texts were intended for silent, individual reading. Interestingly, the authors emphasized the importance of meditation on the texts, too. It was also advised when to read – it wasrecommedend to read in leisure time on Sundays, and on holidays. The role of books was also to breakaway with the reality and to forget everyday problems. Due to the overproduction of books in the 17th centrury it was concerned that books are misleading the crowds. The church considered the reading of books as inappropriate, and criticized fiction, novels and adventure stories mostly read by women.Research limitation: The study is based on Slovenian texts only, although the foreign literature, especially in German, was generally available, too.Originality/practical implications: The study is fullfiling the gap in the history of reading in Slovenia.

  14. How Reading Volume Affects both Reading Fluency and Reading Achievement

    Directory of Open Access Journals (Sweden)

    Richard L. ALLINGTON

    2014-10-01

    Full Text Available Long overlooked, reading volume is actually central to the development of reading proficiencies, especially in the development of fluent reading proficiency. Generally no one in schools monitors the actual volume of reading that children engage in. We know that the commonly used commercial core reading programs provide only material that requires about 15 minutes of reading activity daily. The remaining 75 minute of reading lessons is filled with many other activities such as completing workbook pages or responding to low-level literal questions about what has been read. Studies designed to enhance the volume of reading that children do during their reading lessons demonstrate one way to enhance reading development. Repeated readings have been widely used in fostering reading fluency but wide reading options seem to work faster and more broadly in developing reading proficiencies, including oral reading fluency.

  15. Promoting preschool reading

    OpenAIRE

    Istenič, Vesna

    2013-01-01

    The thesis titled Promoting preschool reading consists of a theoretiral and an empirical part. In the theoretical part I wrote about reading, the importance of reading, types of reading, about reading motivation, promoting reading motivation, internal and external motivation, influence of reading motivation on the child's reading activity, reading and familial literacy, the role of adults in promotion reading literacy, reading to a child and promoting reading in pre-school years, where I ...

  16. Neuroscience of glucose homeostasis

    NARCIS (Netherlands)

    La Fleur, S E; Fliers, E; Kalsbeek, A

    2014-01-01

    Plasma glucose concentrations are homeostatically regulated and maintained within strict boundaries. Several mechanisms are in place to increase glucose output when glucose levels in the circulation drop as a result of glucose utilization, or to decrease glucose output and increase tissue glucose

  17. Reading the Future.

    Science.gov (United States)

    Nettle, Keith

    Given the strong sense of passing time which seems to be wired into human beings, it is only natural that the Year 2000, or Y2K in contemporary jargon, should lead to serious speculation about the future. Reading and literacy, old skills relatively speaking, continue rightly to figure in those predictions (along with the technologically advanced…

  18. Basic Concepts of Reading Instruction

    Directory of Open Access Journals (Sweden)

    Gökhan ARI

    2017-12-01

    Full Text Available Reading act is performed by connected physiological, psychological and cognitive processes. The operations taking place in these processes are expected to continue for life by being developed with certain strategies. A lot of information is gained with reading skill in education life. Therefore, basic concepts that constitute reading education in teaching and improving reading are important for teachers. The aim of this study is to submit information compiled from the literature about reading education process and which basic concepts are used in reading education. While teaching reading from part to whole, from whole to part and interactional approaches are used. From part to whole approach is at the forefront. Then with interactional approach strategies, both code solving and making sense is improved. Teachers should know the characteristics of bouncing, stopping, turning back, and scanning movements of the eye both in code solving and making sense. The teacher should configure the teaching for the students to gain fluid reading elements by making use of reading out and reading silently. After reading act is acquired; good reader characteristics should be gained by improving asking questions, guessing, summarizing, interpretation skills in integrated readings. Reading skill is improved by studies on the text. Therefore, the students should come across texts that are suitable to their levels, textuality and readability criteria. The vocabulary of children should be improved in a planned way with text-based word and meaning studies. Fluid reading, making sense and interpretation skills of children should be pursued with different evaluation types. In the long term, work should be done to make reading a habit for them.

  19. Reading Aloud.

    Science.gov (United States)

    Giorgis, Cyndi; Johnson, Nancy J.

    1999-01-01

    Offers brief descriptions of 34 children's books that are excellent for reading aloud: some of them for inviting interaction, for laughing out loud, for prompting discussion, for living vicariously, for lingering over language, and for making curricular connections. (SR)

  20. Glucose production during exercise in humans

    DEFF Research Database (Denmark)

    Bergeron, R; Kjaer, M; Simonsen, L

    1999-01-01

    at 50.4 +/- 1.5(SE)% maximal O(2) consumption, followed by 30 min at 69.0 +/- 2.2% maximal O(2) consumption. The splanchnic blood flow was estimated by continuous infusion of indocyanine green, and net splanchnic glucose output was calculated as the product of splanchnic blood flow and a-hv blood...... glucose concentration differences. Glucose appearance rate was determined by a primed, continuous infusion of [3-(3)H]glucose and was calculated by using formulas for a modified single compartment in non-steady state. Glucose production was similar whether determined by the a-hv balance technique......The present study compared the arteriohepatic venous (a-hv) balance technique and the tracer-dilution method for estimation of hepatic glucose production during both moderate and heavy exercise in humans. Eight healthy young men (aged 25 yr; range, 23-30 yr) performed semisupine cycling for 40 min...

  1. Blood glucose level reconstruction as a function of transcapillary glucose transport.

    Science.gov (United States)

    Koutny, Tomas

    2014-10-01

    A diabetic patient occasionally undergoes a detailed monitoring of their glucose levels. Over the course of a few days, a monitoring system provides a detailed track of their interstitial fluid glucose levels measured in their subcutaneous tissue. A discrepancy in the blood and interstitial fluid glucose levels is unimportant because the blood glucose levels are not measured continuously. Approximately five blood glucose level samples are taken per day, and the interstitial fluid glucose level is usually measured every 5min. An increased frequency of blood glucose level sampling would cause discomfort for the patient; thus, there is a need for methods to estimate blood glucose levels from the glucose levels measured in subcutaneous tissue. The Steil-Rebrin model is widely used to describe the relationship between blood and interstitial fluid glucose dynamics. However, we measured glucose level patterns for which the Steil-Rebrin model does not hold. Therefore, we based our research on a different model that relates present blood and interstitial fluid glucose levels to future interstitial fluid glucose levels. Using this model, we derived an improved model for calculating blood glucose levels. In the experiments conducted, this model outperformed the Steil-Rebrin model while introducing no additional requirements for glucose sample collection. In subcutaneous tissue, 26.71% of the calculated blood glucose levels had absolute values of relative differences from smoothed measured blood glucose levels less than or equal to 5% using the Steil-Rebrin model. However, the same difference interval was encountered in 63.01% of the calculated blood glucose levels using the proposed model. In addition, 79.45% of the levels calculated with the Steil-Rebrin model compared with 95.21% of the levels calculated with the proposed model had 20% difference intervals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Relative accuracy of the BD Logic and FreeStyle blood glucose meters.

    Science.gov (United States)

    2007-04-01

    The BD Logic((R)) (Becton, Dickinson and Co., Franklin Lakes, NJ) and FreeStyle((R)) (Abbott Diabetes Care, Alameda, CA) meters are used to transmit data directly to insulin pumps for calculation of insulin doses and to calibrate continuous glucose sensors as well as to monitor blood glucose levels. The accuracy of the two meters was evaluated in two inpatient studies conducted by the Diabetes Research in Children Network (DirecNet). In both studies, meter glucose measurements made with either venous or capillary blood were compared with reference glucose measurements made by the DirecNet Central Laboratory at the University of Minnesota using a hexokinase enzymatic method. The BD Logic tended to read lower than the laboratory reference regardless of whether venous (median difference = -9 mg/dL) or capillary blood (median difference = -7 mg/dL) was used. This resulted in lower accuracy of the BD Logic compared with the FreeStyle meter based on the median relative absolute difference (RAD) for both venous blood (median RAD, 9% vs. 5%, P blood (median RAD, 11% vs. 6%, P = 0.008). The greatest discrepancy in the performance of the two meters was at higher reference glucose values. Accuracy was not significantly different when the reference was < or = 70 mg/dL. The BD Logic meter is less accurate than the FreeStyle meter.

  3. A mathematical model of brain glucose homeostasis

    Directory of Open Access Journals (Sweden)

    Kimura Hidenori

    2009-11-01

    Full Text Available Abstract Background The physiological fact that a stable level of brain glucose is more important than that of blood glucose suggests that the ultimate goal of the glucose-insulin-glucagon (GIG regulatory system may be homeostasis of glucose concentration in the brain rather than in the circulation. Methods In order to demonstrate the relationship between brain glucose homeostasis and blood hyperglycemia in diabetes, a brain-oriented mathematical model was developed by considering the brain as the controlled object while the remaining body as the actuator. After approximating the body compartmentally, the concentration dynamics of glucose, as well as those of insulin and glucagon, are described in each compartment. The brain-endocrine crosstalk, which regulates blood glucose level for brain glucose homeostasis together with the peripheral interactions among glucose, insulin and glucagon, is modeled as a proportional feedback control of brain glucose. Correlated to the brain, long-term effects of psychological stress and effects of blood-brain-barrier (BBB adaptation to dysglycemia on the generation of hyperglycemia are also taken into account in the model. Results It is shown that simulation profiles obtained from the model are qualitatively or partially quantitatively consistent with clinical data, concerning the GIG regulatory system responses to bolus glucose, stepwise and continuous glucose infusion. Simulations also revealed that both stress and BBB adaptation contribute to the generation of hyperglycemia. Conclusion Simulations of the model of a healthy person under long-term severe stress demonstrated that feedback control of brain glucose concentration results in elevation of blood glucose level. In this paper, we try to suggest that hyperglycemia in diabetes may be a normal outcome of brain glucose homeostasis.

  4. Glucose and cardiovascular risk

    NARCIS (Netherlands)

    Fuchs, M.; Hoekstra, J. B. L.; Mudde, A. H.

    2002-01-01

    The American Diabetes Association and the World Health Organisation have recently redefined the spectrum of abnormal glucose tolerance. The criteria for diabetes mellitus were sharpened and impaired fasting glucose (IFG) and impaired glucose tolerance (IGT) were classified as intermediate stages

  5. Focusing on EFL reading theory and practice

    CERN Document Server

    Al-Mahrooqi, Rahma

    2014-01-01

    Reading, a complex and multi-faceted skill, is essential for life and academic success. While its mysteries still baffle first-language research, the nature of reading in a foreign language presents an even greater puzzle. However, given reading's importance for EFL students who study their specializations in English, and whose future employment may depend on their competence in it, researchers must continue to investigate foreign language reading and devise ways of improving students' capaci...

  6. [Contribution of the kidney to glucose homeostasis].

    Science.gov (United States)

    Segura, Julián; Ruilope, Luis Miguel

    2013-09-01

    The kidney is involved in glucose homeostasis through three major mechanisms: renal gluconeogenesis, renal glucose consumption, and glucose reabsorption in the proximal tubule. Glucose reabsorption is one of the most important physiological functions of the kidney, allowing full recovery of filtered glucose, elimination of glucose from the urine, and prevention of calorie loss. Approximately 90% of the glucose is reabsorbed in the S1 segment of the proximal tubule, where glucose transporter-2 (GLUT2) and sodium-glucose transporter-2 (SGLT2) are located, while the remaining 10% is reabsorbed in the S3 segment by SGLT1 and GLUT1 transporters. In patients with hyperglycemia, the kidney continues to reabsorb glucose, thus maintaining hyperglycemia. Most of the renal glucose reabsorption is mediated by SGLT2. Several experimental and clinical studies suggest that pharmacological blockade of this transporter might be beneficial in the management of hyperglycemia in patients with type 2 diabetes. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  7. Reading Letters

    DEFF Research Database (Denmark)

    Beier, Sofie

    2012-01-01

    In our everyday life we constantly encounter a diversity of reading matters, including display types on traffic signage, printed text in novels, newspaper headlines, or our own writing on a computer screen. All these conditions place different demands on the typefaces applied. The book discusses...

  8. Reading Rembrandt

    NARCIS (Netherlands)

    Bal, Mieke

    2006-01-01

    Reading Rembrandt: Beyond the Word-Image Opposition explores the potential for an interdisciplinary methodology between visual art and literature. In a series of close analyses of works by "Rembrandt" - works as we see them today, through all the ways of seeing and commenting that precede - and

  9. Does Extensive Reading Promote Reading Speed?

    Science.gov (United States)

    He, Mu

    2014-01-01

    Research has shown a wide range of learning benefits accruing from extensive reading. Not only is there improvement in reading, but also in a wide range of language uses and areas of language knowledge. However, few research studies have examined reading speed. The existing literature on reading speed focused on students' reading speed without…

  10. Glucose Oxidase Biosensor Modeling and Predictors Optimization by Machine Learning Methods.

    Science.gov (United States)

    Gonzalez-Navarro, Felix F; Stilianova-Stoytcheva, Margarita; Renteria-Gutierrez, Livier; Belanche-Muñoz, Lluís A; Flores-Rios, Brenda L; Ibarra-Esquer, Jorge E

    2016-10-26

    Biosensors are small analytical devices incorporating a biological recognition element and a physico-chemical transducer to convert a biological signal into an electrical reading. Nowadays, their technological appeal resides in their fast performance, high sensitivity and continuous measuring capabilities; however, a full understanding is still under research. This paper aims to contribute to this growing field of biotechnology, with a focus on Glucose-Oxidase Biosensor (GOB) modeling through statistical learning methods from a regression perspective. We model the amperometric response of a GOB with dependent variables under different conditions, such as temperature, benzoquinone, pH and glucose concentrations, by means of several machine learning algorithms. Since the sensitivity of a GOB response is strongly related to these dependent variables, their interactions should be optimized to maximize the output signal, for which a genetic algorithm and simulated annealing are used. We report a model that shows a good generalization error and is consistent with the optimization.

  11. Glucose Oxidase Biosensor Modeling and Predictors Optimization by Machine Learning Methods

    Directory of Open Access Journals (Sweden)

    Felix F. Gonzalez-Navarro

    2016-10-01

    Full Text Available Biosensors are small analytical devices incorporating a biological recognition element and a physico-chemical transducer to convert a biological signal into an electrical reading. Nowadays, their technological appeal resides in their fast performance, high sensitivity and continuous measuring capabilities; however, a full understanding is still under research. This paper aims to contribute to this growing field of biotechnology, with a focus on Glucose-Oxidase Biosensor (GOB modeling through statistical learning methods from a regression perspective. We model the amperometric response of a GOB with dependent variables under different conditions, such as temperature, benzoquinone, pH and glucose concentrations, by means of several machine learning algorithms. Since the sensitivity of a GOB response is strongly related to these dependent variables, their interactions should be optimized to maximize the output signal, for which a genetic algorithm and simulated annealing are used. We report a model that shows a good generalization error and is consistent with the optimization.

  12. Slow Reading: Reading along "Lectio" Lines

    Science.gov (United States)

    Badley, K. Jo-Ann; Badley, Ken

    2011-01-01

    The medieval monastic movement preserved and developed reading practices--lectio--from ancient Greek pedagogy as a slow, mindful approach to reading for formation. This ancient way of reading, now better known as lectio divina, challenges the fast, pragmatic reading so characteristic of our time. We propose that the present moment may be ripe for…

  13. Direct reading dosimeter

    International Nuclear Information System (INIS)

    Thomson, I.

    1985-01-01

    This invention is a direct reading dosimeter which is light, small enough to be worn on a person, and measures both dose rates and total dose. It is based on a semiconductor sensor. The gate threshold voltage change rather than absolute value is measured and displayed as a direct reading of the dose rate. This is effected by continuously switching the gate of an MOS transistor from positive to negative bias. The output can directly drive a digital readout or trigger an audible alarm. The sensor device can be a MOSFET, bipolar transistor, or MOSFET capacitor which has its electrical characteristics change due to the trapped charge in the insulating layer of the device

  14. Developing reading literacy by reading badge

    OpenAIRE

    Rejc, Blanka

    2017-01-01

    Reading is a fundamental activity of our society and is present in all areas of a person’s life. Authors who deal with reading define reading with different definitions, some of them I also presented in my master’s degree thesis. The ways of reading, typology of readers and knowledge of different reading models are only some of the important theoretical facts that serve as a basis for the research and defining reading. Reading motivation is an important motivational factor, which encourages a...

  15. Precision and costs of techniques for self-monitoring of serum glucose levels.

    OpenAIRE

    Chiasson, J. L.; Morrisset, R.; Hamet, P.

    1984-01-01

    The poor correlation between serum and urine glucose measurements has led to the development of new techniques for monitoring the blood glucose level in diabetic patients. Either a nurse or the patient can perform these tests, which involve spreading a single drop of blood onto a reagent strip. A colour change that is proportional to the serum glucose level can be read visually or with a reflectance meter. Evaluated against simultaneous serum glucose levels determined by the hospital biochemi...

  16. A glucose oxidase-coupled DNAzyme sensor for glucose detection in tears and saliva.

    Science.gov (United States)

    Liu, Chengcheng; Sheng, Yongjie; Sun, Yanhong; Feng, Junkui; Wang, Shijin; Zhang, Jin; Xu, Jiacui; Jiang, Dazhi

    2015-08-15

    Biosensors have been widely investigated and utilized in a variety of fields ranging from environmental monitoring to clinical diagnostics. Glucose biosensors have triggered great interest and have been widely exploited since glucose determination is essential for diabetes diagnosis. In here, we designed a novel dual-enzyme biosensor composed of glucose oxidase (GOx) and pistol-like DNAzyme (PLDz) to detect glucose levels in tears and saliva. First, GOx, as a molecular recognition element, catalyzes the oxidation of glucose forming H2O2; then PLDz recognizes the produced H2O2 as a secondary signal and performs a self-cleavage reaction promoted by Mn(2+), Co(2+) and Cu(2+). Thus, detection of glucose could be realized by monitoring the cleavage rate of PLDz. The slope of the cleavage rate of PLDz versus glucose concentration curve was fitted with a Double Boltzmann equation, with a range of glucose from 100 nM to 10mM and a detection limit of 5 μM. We further applied the GOx-PLDz 1.0 biosensor for glucose detection in tears and saliva, glucose levels in which are 720±81 μM and 405±56 μM respectively. Therefore, the GOx-PLDz 1.0 biosensor is able to determine glucose levels in tears and saliva as a noninvasive glucose biosensor, which is important for diabetic patients with frequent/continuous glucose monitoring requirements. In addition, induction of DNAzyme provides a new approach in the development of glucose biosensors. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ... you should check and what your blood glucose levels should be. Checking your blood and then treating ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... blood glucose High levels of sugar in the urine Frequent urination Increased thirst Part of managing your ... glucose is above 240 mg/dl, check your urine for ketones. If you have ketones, do not ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... can often lower your blood glucose level by exercising. However, if your blood glucose is above 240 ... ketones. If you have ketones, do not exercise. Exercising when ketones are present may make your blood ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high blood glucose (blood sugar). High ... We Are Research Leaders We Support Your Doctor Student Resources Patient Access to Research Research Resources Practice ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day ... DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get ... the technical term for high blood glucose (blood sugar). High blood glucose happens when the body has ...

  4. [Blood glucose self monitoring].

    Science.gov (United States)

    Wascher, Thomas C; Stechemesser, Lars

    2016-04-01

    Self monitoring of blood glucose contributes to the integrated management of diabetes mellitus. It, thus, should be available for all patients with diabetes mellitus type-1 and type-2. Self monitoring of blood glucose improves patients safety, quality of life and glucose control. The current article represents the recommendations of the Austrian Diabetes Association for the use of blood glucose self monitoring according to current scientific evidence.

  5. PROMOTING AUTONOMOUS LEARNING IN READING CLASS

    Directory of Open Access Journals (Sweden)

    Agus Sholeh

    2015-11-01

    Full Text Available To have good acquisition and awareness in reading, the learners need a long and continuous process, and therefore, they are required to have autonomy in learning reading. This study aims to promote learner autonomy in reading class by combining learner-centered reading teaching and extensive reading teaching. Learner-centered reading teaching was carried out through group discussion, presentation, and language awareness activities. Meanwhile, extensive reading teaching was done to review the learners‘ materials in presentation and reinforce their acquisition. Those two different approaches were applied due to differences on learner's characteristics and needs. The result showed some success in the practice of autonomy, indicated by changes on learners' attitude. However, many learners showed that they focused more on obtaining score than on developing their language acquisition. By implementing the approach, the teacher can assist learners to be aware of their ability to learn independently and equip them with the skill needed for long-life learning.

  6. Reflex reading epilepsy: effect of linguistic characteristics on spike frequency.

    Science.gov (United States)

    Safi, Dima; Lassonde, Maryse; Nguyen, Dang Khoa; Denault, Carole; Macoir, Joël; Rouleau, Isabelle; Béland, Renée

    2011-04-01

    Reading epilepsy is a rare reflex epilepsy in which seizures are provoked by reading. Several cases have been described in the literature, but the pathophysiological processes vary widely and remain unclear. We describe a 42-year-old male patient with reading epilepsy evaluated using clinical assessments and continuous video/EEG recordings. We administered verbal, nonverbal, and reading tasks to determine factors precipitating seizures. Linguistic characteristics of the words were manipulated. Results indicated that reading-induced seizures were significantly more numerous than those observed during verbal and nonverbal tasks. In reading tasks, spike frequency significantly increased with involvement of the phonological reading route. Spikes were recorded predominantly in left parasagittal regions. Future cerebral imaging studies will enable us to visualize the spatial localization and temporal course of reading-induced seizures and brain activity involved in reading. A better understanding of reading epilepsy is crucial for reading rehabilitation in these patients. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Carbohydrate Counting Make Your Carbs Count Glycemic Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type ... Checking Your Blood Glucose A1C and eAG Hypoglycemia (Low blood glucose) Hyperglycemia (High blood glucose) Dawn Phenomenon ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... how often you should check and what your blood glucose levels should be. Checking your blood and then treating ... I Treat Hyperglycemia? You can often lower your blood glucose level by exercising. However, if your blood glucose is ...

  9. Electrocatalytic glucose sensor

    Energy Technology Data Exchange (ETDEWEB)

    Gebhardt, U; Luft, G; Mund, K; Preidel, W; Richter, G J

    1983-01-01

    An artificial pancreas consists of an insulin depot, a dosage unit and a glucose sensor. The measurement of the actual glucose concentration in blood is still an unsolved problem. Two methods are described for an electrocatalytic glucose sensor. Under the interfering action of amino acids and urea in-vitro measurements show an error of between 10% and 20%.

  10. Rearing a reading habit

    OpenAIRE

    Sridhar, M. S.

    2009-01-01

    Discusses the importance and ways of inculcating reading habit in children at the right age, describes the five reading phases in children along with interest and the material to satiate the need, explains how four deterministic factors affect the reading habit of children, enlists motivations that are behind the reading process with tips to improve reading habit of children.

  11. Intraperitoneal Glucose Sensing is Sometimes Surprisingly Rapid

    Directory of Open Access Journals (Sweden)

    Anders Lyngvi Fougner

    2016-04-01

    Full Text Available Rapid, accurate and robust glucose measurements are needed to make a safe artificial pancreas for the treatment of diabetes mellitus type 1 and 2. The present gold standard of continuous glucose sensing, subcutaneous (SC glucose sensing, has been claimed to have slow response and poor robustness towards local tissue changes such as mechanical pressure, temperature changes, etc. The present study aimed at quantifying glucose dynamics from central circulation to intraperitoneal (IP sensor sites, as an alternative to the SC location. Intraarterial (IA and IP sensors were tested in three anaesthetized non-diabetic pigs during experiments with intravenous infusion of glucose boluses, enforcing rapid glucose level excursions in the range 70--360 mg/dL (approximately 3.8--20 mmol/L. Optical interferometric sensors were used for IA and IP measurements. A first-order dynamic model with time delay was fitted to the data after compensating for sensor dynamics. Additionally, off-the-shelf Medtronic Enlite sensors were used for illustration of SC glucose sensing. The time delay in glucose excursions from central circulation (IA to IP sensor location was found to be in the range 0--26 s (median: 8.5 s, mean: 9.7 s, SD 9.5 s, and the time constant was found to be 0.5--10.2 min (median: 4.8 min, mean: 4.7 min, SD 2.9 min. IP glucose sensing sites have a substantially faster and more distinctive response than SC sites when sensor dynamics is ignored, and the peritoneal fluid reacts even faster to changes in intravascular glucose levels than reported in previous animal studies. This study may provide a benchmark for future, rapid IP glucose sensors.

  12. Reading Edward Said in Myanmar

    DEFF Research Database (Denmark)

    Jensen, Lars

    2014-01-01

    Twenty years after its publication, Culture and Imperialism continues to be seen as part of the defining moment of postcolonial readings of our contemporary world. The anniversary marks an opportunity to revisit the landscape of culture and imperialism as envisaged by Edward Said, but also to dis...

  13. Non Invasive Glucose Monitoring System Using Nanosensors

    Directory of Open Access Journals (Sweden)

    Rajasekaran C.

    2016-03-01

    Full Text Available The most existing future technology is an outcome of the fields of computer science, electronics and Biology. Health inequalities have become the focus of a number of descriptive and analytical studies. One of the health related problem is diabetes. Diabetes at its serious stage leads to blindness. Monitoring glucose level in blood is one preventive measure to check diabetes. Increase in Glucose is a common risk factor which leads to hyperglycemia, Hypoglycemia, heart attack, stokes and aneurysms. A glucose monitoring system continuously measures and monitors the glucose level in a patient’s blood. Normal blood glucose level of human is 70-110 milligram/deciliter. The level is maintained by using the secretion of insulin inside the body. When the insulin level gets increased it leads to hyperglycemia, and hypoglycemia when the level gets decreased. Hyperglycemia disease includes cataract,edema, hypertension, polyuria and polydipsia. Hypoglycemaia disease includes confusion, giddiness, unconsciousness, coma and death. The proposed system finds a new way for measuring the glucose level. The work uses Nanopellets which measure’s the glucose level, when the glucose level gets increased or decreased, it will be automatically get monitored and processed using microcontroller (MSP430G2553. The information is then send to the doctor through GSM.

  14. Noninvasive glucose monitoring using saliva nano-biosensor

    Directory of Open Access Journals (Sweden)

    Wenjun Zhang

    2015-06-01

    Full Text Available Millions of people worldwide live with diabetes and several millions die from it each year. A noninvasive, painless method of glucose testing would highly improve compliance and glucose control while reducing complications and overall disease management costs. To provide accurate, low cost, and continuous glucose monitoring, we have developed a unique, disposable saliva nano-biosensor. More than eight clinical trials on real-time noninvasive salivary glucose monitoring were carried out on two healthy individuals (a 2–3 h-period for each trial, including both regular food and standard glucose beverage intake with more than 35 saliva samples obtained. Excellent clinical accuracy was revealed as compared to the UV Spectrophotometer. By measuring subjects’ salivary glucose and blood glucose in parallel, we found the two generated profiles share the same fluctuation trend but the correlation between them is individual dependent. There is a time lag between the peak glucose values from blood and from saliva. However, the correlation between the two glucose values at fasting is constant for each person enabling noninvasive diagnosis of diabetes through saliva instead of blood. Furthermore, a good correlation of glucose levels in saliva and in blood before and 2 h after glucose intake was observed. Glucose monitoring before and 2 h after meals is usually prescribed by doctors for diabetic patients. Thus, this disposable biosensor will be an alternative for real-time salivary glucose tracking at any time.

  15. Dialogic Reading Aloud to Promote Extensive Reading

    Science.gov (United States)

    Jacobs, George M.

    2016-01-01

    How can teachers motivate students to read extensively in a second language? One strategy is for teachers to read aloud to students to promote the joys of reading generally, to build students' language skills and to introduce students to specific authors, book series, genres, websites, etc. This article begins by discussing why teachers might want…

  16. Enhancing academic reading skills through extensive reading ...

    African Journals Online (AJOL)

    Abstract. The current study explores the feasibility of an extensive reading programme in the context of a low-income country (Mozambique), as well as the influence of extensive reading on academic reading. The programme took over 4 months and was conducted among 30 students majoring in Journalism at the Eduardo ...

  17. Determining the Variables That Affect the Reading Motivation of Educational Faculty Students

    Science.gov (United States)

    Savaskan, Vafa; Özdemir, Atilla

    2017-01-01

    Reading motivation has a significant contribution to acquire the necessary reading skills, and it has an indisputable effect on continuing to read. When the importance of the role model effect of school teachers in acquiring reading skills is considered, it is expected that reading motivation of the students will be high whose teachers also have a…

  18. The rate of intestinal glucose absorption is correlated with plasma glucose-dependent insulinotropic polypeptide concentrations in healthy men

    DEFF Research Database (Denmark)

    Wachters-Hagedoorn, Renate E; Priebe, Marion G; Heimweg, Janneke A J

    2006-01-01

    and slowly available glucose. In a crossover study, glucose, insulin, GLP-1, and GIP concentrations were monitored for 6 h after consumption of glucose, uncooked cornstarch (UCCS) or corn pasta in 7 healthy men. All test meals were naturally labeled with 13C. Using a primed, continuous D-[6,6-2H2]glucose...... in the early postprandial phase (15-90 min) occurred after consumption of glucose. There was a strong positive within-subject correlation between RaEx and GIP concentrations (r = 0.73, P meals. Rapidly and slowly digestible carbohydrates differ considerably in their ability to stimulate...

  19. On the Nonsmooth, Nonconstant Velocity of Braille Reading and Reversals

    Science.gov (United States)

    Hughes, Barry; McClelland, Amber; Henare, Dion

    2014-01-01

    Relative to print reading, braille-reading finger movements are held to be of more constant speed, with continuous and exhaustive contact with all words. However, the continuity of movements is intermittent in two distinct ways: (a) readers reverse direction and reread material already encountered and (b) the continual fluctuations of velocity…

  20. Glucose oxidase-functionalized fluorescent gold nanoclusters as probes for glucose

    International Nuclear Information System (INIS)

    Xia, Xiaodong; Long, Yunfei; Wang, Jianxiu

    2013-01-01

    Highlights: ► A glucose oxidase/gold nanocluster conjugates formed by etching chemistry. ► Integration of the bioactivities and fluorescence properties within a single unit. ► These conjugates serve as novel fluorescent probe for glucose. -- Abstract: Creation and application of noble metal nanoclusters have received continuous attention. By integrating enzyme activity and fluorescence for potential applications, enzyme-capped metal clusters are more desirable. This work demonstrated a glucose oxidase (an enzyme for glucose)-functionalized gold cluster as probe for glucose. Under physiological conditions, such bioconjugate was successfully prepared by an etching reaction, where tetrakis (hydroxylmethyl) phosphonium-protected gold nanoparticle and thioctic acid-modified glucose oxidase were used as precursor and etchant, respectively. These bioconjugates showed unique fluorescence spectra (λ em max = 650 nm, λ ex max = 507 nm) with an acceptable quantum yield (ca. 7%). Moreover, the conjugated glucose oxidase remained active and catalyzed reaction of glucose and dissolved O 2 to produce H 2 O 2 , which quenched quantitatively the fluorescence of gold clusters and laid a foundation of glucose detection. A linear range of 2.0 × 10 −6 –140 × 10 −6 M and a detection limit of 0.7 × 10 −6 M (S/N = 3) were obtained. Also, another horseradish peroxidase/gold cluster bioconjugate was produced by such general synthesis method. Such enzyme/metal cluster bioconjugates represented a promising class of biosensors for biologically important targets in organelles or cells

  1. Overnight glucose control in people with type 1 diabetes

    DEFF Research Database (Denmark)

    Boiroux, Dimitri; Duun-Henriksen, Anne Katrine; Schmidt, Signe

    2018-01-01

    This paper presents an individualized model predictive control (MPC) algorithm for overnight blood glucose stabilization in people with type 1 diabetes (T1D). The MPC formulation uses an asymmetric objective function that penalizes low glucose levels more heavily. We compute the model parameters...... algorithm uses frequent glucose measurements from a continuous glucose monitor (CGM) and its decisions are implemented by a continuous subcutaneous insulin infusion (CSII) pump. We provide guidelines for tuning the control algorithm and computing the Kalman gain in the linear state space model in innovation...

  2. Glucose absorption in acute peritoneal dialysis.

    Science.gov (United States)

    Podel, J; Hodelin-Wetzel, R; Saha, D C; Burns, G

    2000-04-01

    During acute peritoneal dialysis (APD), it is known that glucose found in the dialysate solution contributes to the provision of significant calories. It has been well documented in continuous ambulatory peritoneal dialysis (CAPD) that glucose absorption occurs. In APD, however, it remains unclear how much glucose absorption actually does occur. Therefore, the purpose of this study was to determine whether it is appropriate to use the formula used to calculate glucose absorption in CAPD (Grodstein et al) among patients undergoing APD. Actual measurements of glucose absorption (Method I) were calculated in 9 patients undergoing APD treatment for >24 hours who were admitted to the intensive care unit. Glucose absorption using the Grodstein et al formula (Method II) was also determined and compared with the results of actual measurements. The data was then further analyzed based on the factors that influence glucose absorption, specifically dwell time and concentration. The mean total amount of glucose absorbed was 43% +/- 15%. However, when dwell time and concentration were further examined, significant differences were noted. Method I showed a cumulative increase over time. Method II showed that absorption was fixed. This suggests that with the variation in dwell time commonly seen in the acute care setting, the use of Method II may not be accurate. In each of the 2 methods, a significant difference in glucose absorption was noted when comparing the use of 1.5% and 4.25% dialysate concentrations. The established formula designed for CAPD should not be used for calculating glucose absorption in patients receiving APD because variation in dwell time and concentration should be taken into account. Because of the time constraints and staffing required to calculate each exchange individually, combined with the results of the study, we recommend the use of the percentage estimate of 40% to 50%.

  3. Measuring brain glucose phosphorylation with labeled glucose

    International Nuclear Information System (INIS)

    Brondsted, H.E.; Gjedde, A.

    1988-01-01

    This study tested whether glucose labeled at the C-6 position generates metabolites that leave brain so rapidly that C-6-labeled glucose cannot be used to measure brain glucose phosphorylation (CMRGlc). In pentobarbital-anesthetized rats, the parietal cortex uptake of [ 14 C]glucose labeled in the C-6 position was followed for times ranging from 10 s to 60 min. We subtracted the observed radioactivity from the radioactivity expected with no loss of labeled metabolites from brain by extrapolation of glucose uptake in an initial period when loss was negligible. The observed radioactivity was a monoexponentially declining function of the total radioactivity expected in the absence of metabolite loss. The constant of decline was 0.0077.min-1 for parietal cortex. Metabolites were lost from the beginning of the experiment. However, with correction for the loss of labeled metabolites, it was possible to determine an average CMRGlc between 4 and 60 min of circulation of 64 +/- 4 (SE; n = 49) mumol.hg-1.min-1

  4. Characterisation of Maillard reaction products derived from LEKFD--a pentapeptide found in β-lactoglobulin sequence, glycated with glucose--by tandem mass spectrometry, molecular orbital calculations and gel filtration chromatography coupled with continuous photodiode array.

    Science.gov (United States)

    Yamaguchi, Keiko; Homma, Takeshi; Nomi, Yuri; Otsuka, Yuzuru

    2014-02-15

    Maillard reaction peptides (MRPs) contribute to taste, aroma, colour, texture and biological activity. However, peptide degradation or the cross-linking of MRPs in the Maillard reaction has not been investigated clearly. A peptide of LEKFD, a part of β-lactoglobulin, was heated at 110 °C for 24h with glucose and the reaction products were analysed by HPLC with ODS, ESI-MS, ESI-MS/MS and HPLC with gel-filtration column and DAD detector. In the HPLC fractions, an imminium ion of LEK*FD, a pyrylium ion or a hydroxymethyl furylium ion of LEK*FD, and KFD and EK were detected by ESI-MS. Therefore, those products may be produced by the Maillard reaction. The molecular orbital of glycated LEKFD at the lysine epsilon-amino residue with Schiff base form was calculated by MOPAC. HPLC with gel-filtration column showed cross-linking and degradation of peptides. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Theme: Parents and Reading.

    Science.gov (United States)

    Jund, Suzanne, Ed.

    1977-01-01

    This journal issue concentrates on the theme "Parents and Reading." It presents articles on sharing books with young children, using public relations in a reading program, guiding preschool learning, assessing language readiness, working with reading problems, and teaching reading readiness in Wisconsin kindergartens. Resources and a review of…

  6. Psychometric Research in Reading.

    Science.gov (United States)

    Davis, Frederick B.

    This review of psychometric research in reading analyzes the factors which seem related to reading comprehension skills. Experimental analysis of reading comprehension by L. E. Thorndike revealed two major components: knowledge of word meanings and verbal reasoning abilities. Subsequent analysis of experimental studies of reading comprehension…

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications Neuropathy Foot Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ...

  8. Biostable glucose permeable polymer

    DEFF Research Database (Denmark)

    2017-01-01

    A new biostable glucose permeable polymer has been developed which is useful, for example, in implantable glucose sensors. This biostable glucose permeable polymer has a number of advantageous characteristics and, for example, does not undergo hydrolytic cleavage and degradation, thereby providing...... a composition that facilitates long term sensor stability in vivo. The versatile characteristics of this polymer allow it to be used in a variety of contexts, for example to form the body of an implantable glucose sensor. The invention includes the polymer composition, sensor systems formed from this polymer...

  9. Standardization versus customization of glucose reporting.

    Science.gov (United States)

    Rodbard, David

    2013-05-01

    Bergenstal et al. (Diabetes Technol Ther 2013;15:198-211) described an important approach toward standardization of reporting and analysis of continuous glucose monitoring and self-monitoring of blood glucose (SMBG) data. The ambulatory glucose profile (AGP), a composite display of glucose by time of day that superimposes data from multiple days, is perhaps the most informative and useful of the many graphical approaches to display glucose data. However, the AGP has limitations; some variations are desirable and useful. Synchronization with respect to meals, traditionally used in glucose profiles for SMBG data, can improve characterization of postprandial glucose excursions. Several other types of graphical display are available, and recently developed ones can augment the information provided by the AGP. There is a need to standardize the parameters describing glycemic variability and cross-validate the available computer programs that calculate glycemic variability. Clinical decision support software can identify and prioritize clinical problems, make recommendations for modifications of therapy, and explain its justification for those recommendations. The goal of standardization is challenging in view of the diversity of clinical situations and of computing and display platforms and software. Standardization is desirable but must be done in a manner that permits flexibility and fosters innovation.

  10. The glucose oxidase-peroxidase assay for glucose

    Science.gov (United States)

    The glucose oxidase-peroxidase assay for glucose has served as a very specific, sensitive, and repeatable assay for detection of glucose in biological samples. It has been used successfully for analysis of glucose in samples from blood and urine, to analysis of glucose released from starch or glycog...

  11. Estrogens modulate ventrolateral ventromedial hypothalamic glucose-inhibited neurons

    Directory of Open Access Journals (Sweden)

    Ammy M. Santiago

    2016-10-01

    Full Text Available Objective: Brain regulation of glucose homeostasis is sexually dimorphic; however, the impact sex hormones have on specific neuronal populations within the ventromedial hypothalamic nucleus (VMN, a metabolically sensitive brain region, has yet to be fully characterized. Glucose-excited (GE and -inhibited (GI neurons are located throughout the VMN and may play a critical role in glucose and energy homeostasis. Within the ventrolateral portion of the VMN (VL-VMN, glucose sensing neurons and estrogen receptor (ER distributions overlap. We therefore tested the hypothesis that VL-VMN glucose sensing neurons were sexually dimorphic and regulated by 17β-estradiol (17βE. Methods: Electrophysiological recordings of VL-VMN glucose sensing neurons in brain slices isolated from age- and weight-matched female and male mice were performed in the presence and absence of 17βE. Results: We found a new class of VL-VMN GI neurons whose response to low glucose was transient despite continued exposure to low glucose. Heretofore, we refer to these newly identified VL-VMN GI neurons as ‘adapting’ or AdGI neurons. We found a sexual dimorphic response to low glucose, with male nonadapting GI neurons, but not AdGI neurons, responding more robustly to low glucose than those from females. 17βE blunted the response of both nonadapting GI and AdGI neurons to low glucose in both males and females, which was mediated by activation of estrogen receptor β and inhibition of AMP-activated kinase. In contrast, 17βE had no impact on GE or non-glucose sensing neurons in either sex. Conclusion: These data suggest sex differences and estrogenic regulation of VMN hypothalamic glucose sensing may contribute to the sexual dimorphism in glucose homeostasis. Author Video: Author Video Watch what authors say about their articles Keywords: 17β-estradiol, AMP-activated kinase, Glucose excited neurons, Glucose inhibited neurons, Ventromedial hypothalamic nucleus, Sexual dimorphism

  12. 501 reading comprehension questions

    CERN Document Server

    2014-01-01

    This updated edition offers the most extensive and varied practice for all types of questions students might face on standardized and in-class tests. With this guide, students will learn to develop expert reading strategies, understand how to read faster and with greater comprehension, overcome reading anxiety, and increase appreciation of reading for pleasure. This book's step-by-step approach provides graduated coverage that moves from the basics to more advanced reading.

  13. Estimation of glucose rate of appearance from cgs and subcutaneous insulin delivery in type 1 diabetes

    KAUST Repository

    Laleg-Kirati, Taous-Meriem

    2017-08-31

    Method and System for providing estimates of Glucose Rate of Appearance from the intestine (GRA) using continuous glucose sensor measurements (CGS) taken from the subcutaneous of a diabetes patient and the amount of insulin administered to the patient.

  14. Estimation of glucose rate of appearance from cgs and subcutaneous insulin delivery in type 1 diabetes

    KAUST Repository

    Laleg-Kirati, Taous-Meriem; Al-Matouq, Ali Ahmed

    2017-01-01

    Method and System for providing estimates of Glucose Rate of Appearance from the intestine (GRA) using continuous glucose sensor measurements (CGS) taken from the subcutaneous of a diabetes patient and the amount of insulin administered

  15. Safety Campaign Continues

    CERN Multimedia

    2002-01-01

    If you see this poster, stop and read it! This is the third poster produced by TIS Division as part of its information campaign on health and safety in the workplace. It provides statistics on occupational accidents at CERN. You will see that, as in the rest of Europe, falls, slips and trips continue to be the main cause of accident. So, eyes open and take care! For more information : http://safety.cern.ch/

  16. Processing changes across reading encounters.

    Science.gov (United States)

    Levy, B A; Newell, S; Snyder, J; Timmins, K

    1986-10-01

    Five experiments examined changes in the processing of a text across reading encounters. Experiment 1 showed that reading speed increased systematically across encounters, with no loss in the extensiveness of analyses of the printed text, as indicated by the ability to detect nonword errors embedded within that passage. Experiment 2 replicated this improved reading fluency with experience and showed that it occurred even with typescript changes across trials, thus indicating that a primed visual operations explanation cannot account for the effect. The third and fourth experiments then extended the study of the familiarity effect to higher level processing, as indicated by the detection of word errors. Familiarity facilitated the detection of these violations at the syntactic-semantic levels. Finally, Experiment 5 showed that these higher level violations continued to be well detected over a series of reading encounters with the same text. The results indicate that prior experience improves reading speed, with no attenuation of analysis of the printed words or of the passage's message.

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... by Mail Close www.diabetes.org > Living With Diabetes > Treatment and Care > Blood Glucose Testing Share: Print Page ... and-how-tos, . In this section Living With Diabetes Treatment and Care Blood Glucose Testing Checking Your Blood ...

  18. Blood Glucose Determination

    DEFF Research Database (Denmark)

    Lippi, Giuseppe; Nybo, Mads; Cadamuro, Janne

    2018-01-01

    The measurement of fasting plasma glucose may be biased by a time-dependent decrease of glucose in blood tubes, mainly attributable to blood cell metabolism when glycolysis is not rapidly inhibited or blood cells cannot be rapidly separated from plasma. Although glycolysis inhibitors such as sodium...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for ... is checking your blood glucose often. Ask your doctor how often you should ... associated with hyperglycemia. How Do I Treat Hyperglycemia? ...

  20. Brain Glucose Metabolism Controls Hepatic Glucose and Lipid Production

    OpenAIRE

    Lam, Tony K.T.

    2007-01-01

    Brain glucose-sensing mechanisms are implicated in the regulation of feeding behavior and hypoglycemic-induced hormonal counter-regulation. This commentary discusses recent findings indicating that the brain senses glucose to regulate both hepatic glucose and lipid production.

  1. Glucose screening tests during pregnancy

    Science.gov (United States)

    Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... screening test between 24 and 28 weeks of pregnancy. The test may be done earlier if you ...

  2. Reading Disabilities and PASS Reading Enhancement Programme

    Science.gov (United States)

    Mahapatra, Shamita

    2016-01-01

    Children experience difficulties in reading either because they fail to decode the words and thus are unable to comprehend the text or simply fail to comprehend the text even if they are able to decode the words and read them out. Failure in word decoding results from a failure in phonological coding of written information, whereas reading…

  3. To read or not to read

    NARCIS (Netherlands)

    Mol, Suzanne Elizabeth

    2010-01-01

    There is a widely held belief that reading (story)books makes us smarter and helps promote success in life. Does scientific evidence support this notion? The three meta-analyses in this thesis comprise 146 studies between 1988 and 2010 (N=10,308 participants) that addressed the role of book reading

  4. Increased basal glucose production in type 1 Gaucher's disease

    NARCIS (Netherlands)

    Corssmit, E. P.; Hollak, C. E.; Endert, E.; van Oers, M. H.; Sauerwein, H. P.; Romijn, J. A.

    1995-01-01

    To evaluate the metabolic effects of Gaucher's disease, glucose metabolism and parameters of fat metabolism were studied by indirect calorimetry and primed continuous infusion of [3-3H]glucose in seven clinically stable untreated patients with type 1 Gaucher's disease and in seven healthy matched

  5. Continuous auditing & continuous monitoring : Continuous value?

    NARCIS (Netherlands)

    van Hillo, Rutger; Weigand, Hans; Espana, S; Ralyte, J; Souveyet, C

    2016-01-01

    Advancements in information technology, new laws and regulations and rapidly changing business conditions have led to a need for more timely and ongoing assurance with effectively working controls. Continuous Auditing (CA) and Continuous Monitoring (CM) technologies have made this possible by

  6. Coexistence of insulin resistance and increased glucose tolerance in pregnant rats: a physiological mechanism for glucose maintenance.

    Science.gov (United States)

    Carrara, Marcia Aparecida; Batista, Márcia Regina; Saruhashi, Tiago Ribeiro; Felisberto, Antonio Machado; Guilhermetti, Marcio; Bazotte, Roberto Barbosa

    2012-06-06

    The contribution of insulin resistance (IR) and glucose tolerance to the maintenance of blood glucose levels in non diabetic pregnant Wistar rats (PWR) was investigated. PWR were submitted to conventional insulin tolerance test (ITT) and glucose tolerance test (GTT) using blood sample collected 0, 10 and 60 min after intraperitoneal insulin (1 U/kg) or oral (gavage) glucose (1g/kg) administration. Moreover, ITT, GTT and the kinetics of glucose concentration changes in the fed and fasted states were evaluated with a real-time continuous glucose monitoring system (RT-CGMS) technique. Furthermore, the contribution of the liver glucose production was investigated. Conventional ITT and GTT at 0, 7, 14 and 20 days of pregnancy revealed increased IR and glucose tolerance after 20 days of pregnancy. Thus, this period of pregnancy was used to investigate the kinetics of glucose changes with the RT-CGMS technique. PWR (day 20) exhibited a lower (pinsulin sensitivity and/or glucose tolerance during late pregnancy. In contrast to the general view that IR is a pathological process associated with gestational diabetes, a certain degree of IR may represent an important physiological mechanism for blood glucose maintenance during fasting. Copyright © 2012 Elsevier Inc. All rights reserved.

  7. Effects of hyperglycemia on glucose production and utilization in humans. Measurement with [3H]-2-, [3H]-3-, and [14C]-6-glucose

    International Nuclear Information System (INIS)

    Bell, P.M.; Firth, R.G.; Rizza, R.A.

    1986-01-01

    Studies with tritiated isotopes of glucose have demonstrated that hyperglycemia per se stimulates glucose utilization and suppresses glucose production in humans. These conclusions rely on the assumption that tritiated glucose provides an accurate measure of glucose turnover. However, if in the presence of hyperglycemia the isotope either loses its label during futile cycling or retains its label during cycling through glycogen, then this assumption is not valid. To examine this question, glucose utilization and glucose production rates were measured in nine normal subjects with a simultaneous infusion of [ 3 H]-2-glucose, an isotope that may undergo futile cycling but does not cycle through glycogen; [ 14 C]-6-glucose, an isotope that may cycle through glycogen but does not futile cycle; and [ 3 H]-3-glucose, an isotope that can both undergo futile cycling and cycle through glycogen. In the postabsorptive state at plasma glucose concentration of 95 mg X dl-1, glucose turnover determined with [ 14 C]-6-glucose (2.3 +/- 0.1 mg X kg-1 X min-1) was greater than that determined with [3 3 H]glucose (2.1 +/- 0.1 mg X kg-1 X min-1, P = 0.002) and slightly less than that determined with [ 3 H]-2-glucose (2.7 +/- 0.2 mg X kg-1 X min-1, P = 0.08). Plasma glucose was then raised from 95 to 135 to 175 mg X dl-1 while insulin secretion was inhibited, and circulating insulin, glucagon, and growth hormone concentrations were maintained constant by infusion of these hormones and somatostatin. Glucose production and utilization rates determined with [ 14 C]-6-glucose continued to be less than those determined with [ 3 H]-2-glucose and greater than those seen with [ 3 H]-3-glucose

  8. In vitro hydrogen production by glucose dehydrogenase and hydrogenase

    Energy Technology Data Exchange (ETDEWEB)

    Woodward, J. [Oak Ridge National Lab., TN (United States)

    1996-10-01

    A new in vitro enzymatic pathway for the generation of molecular hydrogen from glucose has been demonstrated. The reaction is based upon the oxidation of glucose by Thermoplasma acidophilum glucose dehydrogenase with the concomitant oxidation of NADPH by Pyrococcus furiosus hydrogenase. Stoichiometric yields of hydrogen were produced from glucose with continuous cofactor recycle. This simple system may provide a method for the biological production of hydrogen from renewable sources. In addition, the other product of this reaction, gluconic acid, is a high-value commodity chemical.

  9. Adult reading teachers’ beliefs about how less-skilled adult readers can be taught to read.

    Directory of Open Access Journals (Sweden)

    Janet McHardy

    2016-12-01

    Full Text Available Despite large-scale interventions, significant numbers of adults worldwide continue to have problems with basic literacy, in particular in the area of reading. To be effective, adult reading teachers need expert knowledge at practitioner level. However, practices in adult reading education vary widely, often reflecting the individual beliefs of each teacher about how an adult can learn to read. In this study, phenomenographic analysis was used to identify categories of approaches to teaching adult reading, used by a group of 60 teachers in Western Australia and New Zealand. Four approaches were identified: reassurance, task-based, theory-based and responsive. It is argued that for teachers to become effective and consistent in responding to learner needs, they must understand their own beliefs and the consequences of these. The identification of different approaches in adult reading education is an important step in this process.

  10. Guided Reading and Motivation

    Science.gov (United States)

    Hauptman, Allyson L.

    2012-01-01

    The purpose of this study was to determine the relationship between Guided Reading and student motivation to read across fourth, fifth, and sixth grades. The study defined literacy motivation as: (a) task value; (b) self-perceived competence; (c) students' perceptions of the Guided Reading format. Factor analysis and repeated measures ANOVAs were…

  11. Readability and Reading Ability.

    Science.gov (United States)

    Wright, Benjamin D.; Stenner, A. Jackson

    This document discusses the measurement of reading ability and the readability of books by application of the Lexile framework. It begins by stating the importance of uniform measures. It then discusses the history of reading ability testing, based on the assumption that no researcher has been able to measure more than one kind of reading ability.…

  12. Reading and Empathy

    Science.gov (United States)

    McCreary, John J.; Marchant, Gregory J.

    2017-01-01

    The relationship between reading and empathy was explored. Controlling for GPA and gender, reading variables were hypothesized as related to empathy; the relationship was expected to differ for males and females. For the complete sample, affective components were related to GPA but not reading. Perspective taking was related to reading…

  13. Free Reading Is UTOPIA

    Science.gov (United States)

    LeCrone, Nancy

    2010-01-01

    In high school students get tied up in extracurricular activities and have little time for pleasure reading. It is true that with rigorous academic schedules they have little time for pleasure reading. Thus began a conversation with a sophomore English teacher at the author's high school. As they were discussing the plight of free reading he was…

  14. Reading: United States.

    Science.gov (United States)

    Weber, Rose-Marie

    1983-01-01

    An exploration of the increasingly important role of linguistics in literacy research and instruction reviews literature on reading comprehension, written language, orthography, metalinguistics, classroom language use, reading disabilities, native tongues, nonstandard dialects, bilingual education, adult literacy, and second-language reading. (86…

  15. Teaching Reading with Puppets.

    Science.gov (United States)

    Bennett, Ruth

    The use of traditional stories in American Indian language programs connects students' reading to their lives and familiarizes learners with the rhythms of the oral language. Puppet performances are one way of connecting reading programs to the Native oral tradition. A high school reading lesson in a first-year Hupa language class uses many…

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type 1 Type 2 Facts About Type 2 Enroll ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... to Give Close Are You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication ... Learning at Camp Find a Camp Fundraising Events Step Out Walk to Stop Diabetes Tour de Cure ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... EXPO Volunteer Opportunities Sponsorship and Exhibit Opportunities Camp ... when ketones are present may make your blood glucose level go even higher. You'll need to work with your doctor ...

  1. CSF glucose test

    Science.gov (United States)

    ... in the space surrounding the spinal cord and brain. ... Abnormal results include higher and lower glucose levels. Abnormal results may be due to: Infection (bacterial or fungus) Inflammation of the central nervous system Tumor

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Clinical Practice Guidelines Patient Education Materials Scientific Sessions Journals for Professionals Professional Books Patient Access to Research ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Diabetes Meal Plans Create Your Plate Gluten Free Diets Meal Planning for Vegetarian Diets Cook with Heart- ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Index Low-Calorie Sweeteners Sugar and Desserts Fitness Exercise & Type 1 Diabetes Get Started Safely Get And ...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More ... us get closer to curing diabetes and better treatments for those living with diabetes. Other Ways to ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... for energy. When your body breaks down fats, waste products called ketones are produced. Your body cannot ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  7. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... breast cancer and AIDS combined. Your gift today will help us get closer to curing diabetes and ... blood and then treating high blood glucose early will help you avoid problems associated with hyperglycemia. How ...

  8. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers ... updated, this is the "take-you-by-the-hand" guide that will become a trusted friend and ...

  9. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics Home Symptoms Diagnosis America's Diabetes Challenge Type ...

  10. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & Fitness Home ... symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ...

  11. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ... Day in the Life of Diabetes Famous People Working to Stop Diabetes Common Terms Diabetes Statistics Infographics ...

  12. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Superfoods Non-starchy Vegetables Grains and Starchy Vegetables Fats Alcohol What Can I Drink? Fruit Dairy Food ... glucose for fuel, so your body breaks down fats to use for energy. When your body breaks ...

  13. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... someone new is diagnosed. Diabetes causes more deaths a year than breast cancer and AIDS combined. Your gift today will help ...

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Care > Blood Glucose Testing Share: Print Page Text Size: A A A Listen En Español Hyperglycemia ( ... compact USB drives that can carry a person's full medical record for use in an emergency. How ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... for Association Events Messaging Tools Recruiting Advocates Local Market Planning Training Webinars News & Events Advocacy News Call ... Care > Blood Glucose Testing Share: Print Page Text Size: A A A Listen En Español Hyperglycemia (High ...

  16. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral ... 2 Diabetes Know Your Rights Employment Discrimination Health Care Professionals Law Enforcement Driver's License For Lawyers Food & ...

  18. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy 8 Tips for Caregivers Health ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... blood glucose level go even higher. You'll need to work with your doctor to find the ... lead to ketoacidosis. Ketoacidosis is life-threatening and needs immediate treatment. Symptoms include: Shortness of breath Breath ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... your blood and then treating high blood glucose early will help you avoid problems associated with hyperglycemia. ... to detect hyperglycemia so you can treat it early — before it gets worse. If you're new ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To ... Email: Sign Up Thank you for signing up ' + ' '); $('.survey-form').show(); }, success: function (data) { $('#survey-errors').remove(); $('. ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ... Living With Diabetes Recently Diagnosed Treatment & Care Complications Health ... EXPOs Awareness Programs Wellness Lives Here Become a Member American ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Your best bet is to practice good diabetes management and learn to detect hyperglycemia so you can ... glucose) Dawn Phenomenon Checking for Ketones Tight Diabetes Control donate en -- A Future Without Diabetes - a-future- ...

  5. Unsuspected glucose abnormalities in patients with coronary artery ...

    African Journals Online (AJOL)

    2006-05-25

    May 25, 2006 ... American Diabetic Association (ADA) fasting glucose criteria compared with .... Continuous data were compared using the Kruskal-. Wallis test and .... hyperlipidaemia, hypertension and obesity (if present). Diagnosing DM as ...

  6. Glucose utilization and anti-oxidative mechanisms of the aqueous ...

    African Journals Online (AJOL)

    olayemitoyin

    the local management of diabetes mellitus, obesity and hyperlipidemia. ... body weight changes and fasting blood glucose (FBG) were determined on days 1 and 15 of the experiment. .... water after which it was continuously and completely.

  7. Developmental relations between reading comprehension and reading strategies

    OpenAIRE

    Muijselaar, M.M.L.; Swart, N.M.; Steenbeek-Planting, E.G.; Droop, W.; Verhoeven, L.T.W.; Jong, P.F. de

    2017-01-01

    We examined the developmental relations between knowledge of reading strategies and reading comprehension in a longitudinal study of 312 Dutch children from the beginning of fourth grade to the end of fifth grade. Measures for reading comprehension, reading strategies, reading fluency, vocabulary, and working memory were administered. A structural equation model was constructed to estimate the unique relations between reading strategies and reading comprehension, while controlling for reading...

  8. Glucose-reducing effect of the ORMD-0801 oral insulin preparation in patients with uncontrolled type 1 diabetes: a pilot study.

    Directory of Open Access Journals (Sweden)

    Roy Eldor

    Full Text Available The unpredictable behavior of uncontrolled type 1 diabetes often involves frequent swings in blood glucose levels that impact maintenance of a daily routine. An intensified insulin regimen is often unsuccessful, while other therapeutic options, such as amylin analog injections, use of continuous glucose sensors, and islet or pancreas transplantation are of limited clinical use. In efforts to provide patients with a more compliable treatment method, Oramed Pharmaceuticals tested the capacity of its oral insulin capsule (ORMD-0801, 8 mg insulin in addressing this resistant clinical state. Eight Type I diabetes patients with uncontrolled diabetes (HbA1c: 7.5-10% were monitored throughout the 15-day study period by means of a blind continuous glucose monitoring device. Baseline patient blood glucose behavior was monitored and recorded over a five-day pretreatment screening period. During the ensuing ten-day treatment phase, patients were asked to conduct themselves as usual and to self-administer an oral insulin capsule three times daily, just prior to meal intake. CGM data sufficient for pharmacodynamics analyses were obtained from 6 of the 8 subjects. Treatment with ORMD-0801 was associated with a significant 24.4% reduction in the frequencies of glucose readings >200 mg/dL (60.1 ± 7.9% pretreatment vs. 45.4 ± 4.9% during ORMD-0801 treatment; p = 0.023 and a significant mean 16.6% decrease in glucose area under the curve (AUC (66055 ± 5547 mg/dL/24 hours vs. 55060 ± 3068 mg/dL/24 hours, p = 0.023, with a greater decrease during the early evening hours. In conclusion, ORMD-0801 oral insulin capsules in conjunction with subcutaneous insulin injections, well tolerated and effectively reduced glycemia throughout the day.Clinicaltrials.gov NCT00867594.

  9. Teacher's reading comprehension: Implication for teaching practices

    Directory of Open Access Journals (Sweden)

    Adriana Benevides Soares

    2010-11-01

    Full Text Available A question of interest for educational workers is the reading comprehension process, a fundamental ability for progress in more advanced years of schooling, and its effect on pedagogical practices. This is a study that explores this question. A reading comprehension instrument composed by four structural levels of text and a scale of pedagogical practice composed by four sub-scales involving: cognitive practices with linguistic focus, cognitive practices, affective and motor practices, continuous education, was used. The results of 53 children suggest a slight tendency of teacher to prioritize cognitive practices independently of their reading comprehension level.

  10. Change in blood glucose level in rats after immobilization

    Science.gov (United States)

    Platonov, R. D.; Baskakova, G. M.; Chepurnov, S. A.

    1981-01-01

    Experiments were carried out on male white rats divided into four groups. In group one the blood glucose level was determined immediately after immobilization. In the other three groups, two hours following immobilization, the blood glucose level was determined every 20 minutes for 3 hours 40 minutes by the glucose oxidase method. Preliminary immobilization for 2 hours removed the increase in the blood glucose caused by the stress reaction. By the 2nd hour of immobilization in the presence of continuing stress, the blood glucose level stabilized and varied within 42 + or - 5.5 and 47 + or - 8.1 mg %. Within 2 hours after the immobilization, the differences in the blood glucose level of the rats from the control groups were statistically insignificant.

  11. Reading Comprehension Strategies

    Directory of Open Access Journals (Sweden)

    Unal Ulker

    2017-12-01

    Full Text Available The academic success of the university students greatly depends on the mastery of an academic reading skill. However, students as well as teachers, take the learning of this skill for granted, as they tend to presuppose that reading skill is acquired as a part of their secondary education. As a result, most first-year students employ non university strategies to read academic texts, which leads to a surface approach to reading and prevents students from a better understanding of the material. This paper will discuss the strategies that involve students in taking a deep approach to reading academic texts.

  12. Reading use in preschool

    OpenAIRE

    Laísa Cristina dos Santos Guilherme; Rodrigo Ferreira Daverni

    2016-01-01

    Abstract: Reading in preschool is a time of awakening the taste and pleasure in reading, it is also a source of reflection, discovery and learn to listen. It is then necessary that the contact with the reading start from pre-school, with a variety of texts and the teacher also has the habit of reading in their daily lives. Therefore, this study aimed to investigate the benefits of daily reading in the classroom pre-school life of a student, which the characteristics of a player and teacher re...

  13. What oral text reading fluency can reveal about reading comprehension

    NARCIS (Netherlands)

    Veenendaal, N.J.; Groen, M.A.; Verhoeven, L.T.W.

    2015-01-01

    Text reading fluency – the ability to read quickly, accurately and with a natural intonation – has been proposed as a predictor of reading comprehension. In the current study, we examined the role of oral text reading fluency, defined as text reading rate and text reading prosody, as a contributor

  14. Computer Vision Syndrome for Non-Native Speaking Students: What Are the Problems with Online Reading?

    Science.gov (United States)

    Tseng, Min-chen

    2014-01-01

    This study investigated the online reading performances and the level of visual fatigue from the perspectives of non-native speaking students (NNSs). Reading on a computer screen is more visually more demanding than reading printed text. Online reading requires frequent saccadic eye movements and imposes continuous focusing and alignment demand.…

  15. Glucosensing in the gastrointestinal tract: Impact on glucose metabolism

    Science.gov (United States)

    Fournel, Audren; Marlin, Alysson; Abot, Anne; Pasquio, Charles; Cirillo, Carla; Cani, Patrice D.

    2016-01-01

    The gastrointestinal tract is an important interface of exchange between ingested food and the body. Glucose is one of the major dietary sources of energy. All along the gastrointestinal tube, e.g., the oral cavity, small intestine, pancreas, and portal vein, specialized cells referred to as glucosensors detect variations in glucose levels. In response to this glucose detection, these cells send hormonal and neuronal messages to tissues involved in glucose metabolism to regulate glycemia. The gastrointestinal tract continuously communicates with the brain, especially with the hypothalamus, via the gut-brain axis. It is now well established that the cross talk between the gut and the brain is of crucial importance in the control of glucose homeostasis. In addition to receiving glucosensing information from the gut, the hypothalamus may also directly sense glucose. Indeed, the hypothalamus contains glucose-sensitive cells that regulate glucose homeostasis by sending signals to peripheral tissues via the autonomous nervous system. This review summarizes the mechanisms by which glucosensors along the gastrointestinal tract detect glucose, as well as the results of such detection in the whole body, including the hypothalamus. We also highlight how disturbances in the glucosensing process may lead to metabolic disorders such as type 2 diabetes. A better understanding of the pathways regulating glucose homeostasis will further facilitate the development of novel therapeutic strategies for the treatment of metabolic diseases. PMID:26939867

  16. Glucosensing in the gastrointestinal tract: Impact on glucose metabolism.

    Science.gov (United States)

    Fournel, Audren; Marlin, Alysson; Abot, Anne; Pasquio, Charles; Cirillo, Carla; Cani, Patrice D; Knauf, Claude

    2016-05-01

    The gastrointestinal tract is an important interface of exchange between ingested food and the body. Glucose is one of the major dietary sources of energy. All along the gastrointestinal tube, e.g., the oral cavity, small intestine, pancreas, and portal vein, specialized cells referred to as glucosensors detect variations in glucose levels. In response to this glucose detection, these cells send hormonal and neuronal messages to tissues involved in glucose metabolism to regulate glycemia. The gastrointestinal tract continuously communicates with the brain, especially with the hypothalamus, via the gut-brain axis. It is now well established that the cross talk between the gut and the brain is of crucial importance in the control of glucose homeostasis. In addition to receiving glucosensing information from the gut, the hypothalamus may also directly sense glucose. Indeed, the hypothalamus contains glucose-sensitive cells that regulate glucose homeostasis by sending signals to peripheral tissues via the autonomous nervous system. This review summarizes the mechanisms by which glucosensors along the gastrointestinal tract detect glucose, as well as the results of such detection in the whole body, including the hypothalamus. We also highlight how disturbances in the glucosensing process may lead to metabolic disorders such as type 2 diabetes. A better understanding of the pathways regulating glucose homeostasis will further facilitate the development of novel therapeutic strategies for the treatment of metabolic diseases. Copyright © 2016 the American Physiological Society.

  17. Glucose-6-phosphatase deficiency

    Directory of Open Access Journals (Sweden)

    Labrune Philippe

    2011-05-01

    commonly confirmed by G6PC (GSDIa or SLC37A4 (GSDIb gene analysis, and the indications of liver biopsy to measure G6P activity are getting rarer and rarer. Differential diagnoses include the other GSDs, in particular type III (see this term. However, in GSDIII, glycemia and lactacidemia are high after a meal and low after a fast period (often with a later occurrence than that of type I. Primary liver tumors and Pepper syndrome (hepatic metastases of neuroblastoma may be evoked but are easily ruled out through clinical and ultrasound data. Antenatal diagnosis is possible through molecular analysis of amniocytes or chorionic villous cells. Pre-implantatory genetic diagnosis may also be discussed. Genetic counseling should be offered to patients and their families. The dietary treatment aims at avoiding hypoglycemia (frequent meals, nocturnal enteral feeding through a nasogastric tube, and later oral addition of uncooked starch and acidosis (restricted fructose and galactose intake. Liver transplantation, performed on the basis of poor metabolic control and/or hepatocarcinoma, corrects hypoglycemia, but renal involvement may continue to progress and neutropenia is not always corrected in type Ib. Kidney transplantation can be performed in case of severe renal insufficiency. Combined liver-kidney grafts have been performed in a few cases. Prognosis is usually good: late hepatic and renal complications may occur, however, with adapted management, patients have almost normal life span. Disease name and synonyms Glucose-6-phosphatase deficiency or G6P deficiency or glycogen storage disease type I or GSDI or type I glycogenosis or Von Gierke disease or Hepatorenal glycogenosis.

  18. Clinical assessment of the accuracy of blood glucose measurement devices.

    Science.gov (United States)

    Pfützner, Andreas; Mitri, Michael; Musholt, Petra B; Sachsenheimer, Daniela; Borchert, Marcus; Yap, Andrew; Forst, Thomas

    2012-04-01

    Blood glucose meters for patient self-measurement need to comply with the accuracy standards of the ISO 15197 guideline. We investigated the accuracy of the two new blood glucose meters BG*Star and iBG*Star (Sanofi-Aventis) in comparison to four other competitive devices (Accu-Chek Aviva, Roche Diagnostics; FreeStyle Freedom Lite, Abbott Medisense; Contour, Bayer; OneTouch Ultra 2, Lifescan) at different blood glucose ranges in a clinical setting with healthy subjects and patients with type 1 and type 2 diabetes. BGStar and iBGStar are employ dynamic electrochemistry, which is supposed to result in highly accurate results. The study was performed on 106 participants (53 female, 53 male, age (mean ± SD): 46 ± 16 years, type 1: 32 patients, type 2: 34 patients, and 40 healthy subjects). Two devices from each type and strips from two different production lots were used for glucose assessment (∼200 readings/meter). Spontaneous glucose assessments and glucose or insulin interventions under medical supervision were applied to perform measurements in the different glucose ranges in accordance with the ISO 15197 requirements. Sample values 400 mg/dL were prepared by laboratory manipulations. The YSI glucose analyzer (glucose oxidase method) served as the standard reference method which may be considered to be a limitation in light of glucose hexokinase-based meters. For all devices, there was a very close correlation between the glucose results compared to the YSI reference method results. The correlation coefficients were r = 0.995 for BGStar and r = 0.992 for iBGStar (Aviva: 0.995, Freedom Lite: 0.990, Contour: 0.993, Ultra 2: 0.990). Error-grid analysis according to Parkes and Clarke revealed both 100% of the readings to be within the clinically acceptable areas (Clarke: A + B with BG*Star (100 + 0), Aviva (97 + 3), and Contour (97 + 3); and 99.5% with iBG*Star (97.5 + 2), Freedom Lite (98 + 1.5), and Ultra 2 (97.5 + 2

  19. Glucose oxidase-functionalized fluorescent gold nanoclusters as probes for glucose

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Xiaodong [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China); School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201 (China); Long, Yunfei, E-mail: l_yunfei927@163.com [School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan 411201 (China); Wang, Jianxiu, E-mail: jxiuwang@csu.edu.cn [College of Chemistry and Chemical Engineering, Central South University, Changsha 410083 (China)

    2013-04-15

    Highlights: ► A glucose oxidase/gold nanocluster conjugates formed by etching chemistry. ► Integration of the bioactivities and fluorescence properties within a single unit. ► These conjugates serve as novel fluorescent probe for glucose. -- Abstract: Creation and application of noble metal nanoclusters have received continuous attention. By integrating enzyme activity and fluorescence for potential applications, enzyme-capped metal clusters are more desirable. This work demonstrated a glucose oxidase (an enzyme for glucose)-functionalized gold cluster as probe for glucose. Under physiological conditions, such bioconjugate was successfully prepared by an etching reaction, where tetrakis (hydroxylmethyl) phosphonium-protected gold nanoparticle and thioctic acid-modified glucose oxidase were used as precursor and etchant, respectively. These bioconjugates showed unique fluorescence spectra (λ{sub em} {sub max} = 650 nm, λ{sub ex} {sub max} = 507 nm) with an acceptable quantum yield (ca. 7%). Moreover, the conjugated glucose oxidase remained active and catalyzed reaction of glucose and dissolved O{sub 2} to produce H{sub 2}O{sub 2}, which quenched quantitatively the fluorescence of gold clusters and laid a foundation of glucose detection. A linear range of 2.0 × 10{sup −6}–140 × 10{sup −6} M and a detection limit of 0.7 × 10{sup −6} M (S/N = 3) were obtained. Also, another horseradish peroxidase/gold cluster bioconjugate was produced by such general synthesis method. Such enzyme/metal cluster bioconjugates represented a promising class of biosensors for biologically important targets in organelles or cells.

  20. Continuous Problem of Function Continuity

    Science.gov (United States)

    Jayakody, Gaya; Zazkis, Rina

    2015-01-01

    We examine different definitions presented in textbooks and other mathematical sources for "continuity of a function at a point" and "continuous function" in the context of introductory level Calculus. We then identify problematic issues related to definitions of continuity and discontinuity: inconsistency and absence of…

  1. Erroneous glucose recordings while using mutant variant of quinoprotein glucose dehydrogenase glucometer in a child with galactosemia

    Directory of Open Access Journals (Sweden)

    Vivek Mathew

    2013-01-01

    Full Text Available We report a 2-month-old child with galactosemia and falsely high glucose readings with a glucometer using mutant variant of quinoprotein glucose dehydrogenase (MutQ-GDH chemistry. Potentially fatal hypoglycemia could have been induced in the child if insulin infusion had been initiated as per glycemic management protocol. Even though, the product information with the glucometer carries warning regarding interference by high galactose levels, the awareness regarding this interaction is generally poor in many practice settings. Although, false readings have been reported with glucose dehydrogenase pyrroloquinoline quinone (GDH-PQQ glucometers, to our knowledge this is the first case report of a falsely high glucose reading due to high galactose in a proven case of galactosemia with a glucometer using the MutQ-GDH chemistry (a modified GDH-PQQ chemistry. Our experience has prompted us to write this case report and we suggest avoiding these glucometers in neonates and infants when a metabolic disease is suspected.

  2. Pulsatile hyperglucagonemia fails to increase hepatic glucose production in normal man

    International Nuclear Information System (INIS)

    Paolisso, G.; Scheen, A.J.; Luyckx, A.S.; Lefebvre, P.J.

    1987-01-01

    To study the metabolic effects of pulsatile glucagon administration, six male volunteers were submitted to a 260-min glucose-controlled glucose intravenous infusion using the Biostator. The endogenous secretion of the pancreatic hormones was inhibited by somatostatin, basal insulin secretion was replaced by a continuous insulin infusion, and glucagon was infused intravenously in two conditions at random: either continuously or intermittently. Blood glucose levels and glucose infusion rate were monitored continuously by the Biostator, and classical methodology using a D-[3- 3 H]glucose infusion allowed the authors to study glucose turnover. While basal plasma glucagon levels were similar in both conditions, they plateaued at 189 +/- 38 pg ml -1 during continuous infusion and varied between 95 and 501 pg x ml -1 during pulsatile infusion. When compared with continuous administration, pulsatile glucagon infusion 1) initially induced a similar increase in endogenous (hepatic) glucose production and blood glucose, 2) did not prevent the so-called evanescent effect of glucagon on blood glucose, and 3) after 3 h tended to reduce rather than increase hepatic glucose production. In conclusion, in vivo pulsatile hyperglucanemia in normal man fails to increase hepatic glucose production

  3. Exploring the Relationship between Adolescent's Reading Skills, Reading Motivation and Reading Habits

    Science.gov (United States)

    McGeown, Sarah P.; Duncan, Lynne G.; Griffiths, Yvonne M.; Stothard, Sue E.

    2015-01-01

    The present study examines the extent to which adolescents' reading affect (reading motivation) and behaviour (reading habits) predict different components of reading (word reading, comprehension, summarisation and text reading speed) and also adds to the limited research examining group differences (gender, age, ability) in adolescents' reading…

  4. Approaching to DM2 through sodium-glucose cotransporter-2: does it make sense?

    Science.gov (United States)

    Segura, Julián

    2016-11-01

    The kidney is involved in glucose homeostasis through three main mechanisms: renal gluconeogenesis, renal glucose consumption and glucose reabsorption in the proximal tubule. Glucose reabsorption is one of the most relevant physiological functions of the kidney, through which filtered glucose is fully recovered, urine is free of glucose, and calorie loss is prevented. Approximately 90% of the glucose is reabsorbed in the S1 segment of the proximal tubule, where GLUT2 and SGLT2 transporters are located, while the remaining 10% is reabsorbed in the S3 segment by SGLT1 and GLUT1 transporters. In patients with hyperglycaemia, the kidney continues reabsorbing glucose, and hyperglycaemia is maintained. Most renal glucose reabsorption is mediated by the SGLT2 transporter. Several experimental and clinical studies suggest that pharmacological blockade of this transporter might be beneficial in the management of hyperglycemia in patients with type 2 diabetes. Copyright © 2016 Elsevier España, S.L.U. All rights reserved.

  5. Reading in developmental prosopagnosia

    DEFF Research Database (Denmark)

    Starrfelt, Randi; Klargaard, Solja K; Petersen, Anders

    2018-01-01

    exposure durations (targeting the word superiority effect), and d) text reading. RESULTS: Participants with developmental prosopagnosia performed strikingly similar to controls across the four reading tasks. Formal analysis revealed a significant dissociation between word and face recognition......, that is, impaired reading in developmental prosopagnosia. METHOD: We tested 10 adults with developmental prosopagnosia and 20 matched controls. All participants completed the Cambridge Face Memory Test, the Cambridge Face Perception test and a Face recognition questionnaire used to quantify everyday face...... recognition experience. Reading was measured in four experimental tasks, testing different levels of letter, word, and text reading: (a) single word reading with words of varying length,(b) vocal response times in single letter and short word naming, (c) recognition of single letters and short words at brief...

  6. INTEREST AND READING MOTIVATION

    Directory of Open Access Journals (Sweden)

    Alhamdu Alhamdu

    2016-05-01

    Full Text Available The purpose of this study is to examine the relationship between interest and reading motivation based on literature review. The concept of the interest portrayed as a psychological state that occurs during interaction between individual and specific topic, object or activity including process of willingness, increased attention, concentration and positive feeling to the topic, object or activity. Meanwhile reading motivation emphasized to mental readiness, willingness and refers to beliefs and perception of individual to engage in reading activity. Some researchers were identified factors that influenced reading motivation such as intrinsic and extrinsic factors, self-concept and value of reading, and interest. In general, the literature review described that have positive relationship between interest and reading motivation.

  7. Motivational reading on education, meaningful reading realisation

    Directory of Open Access Journals (Sweden)

    Adriana Qafa

    2017-07-01

    Full Text Available In this study I will present some ideas on today’s educational practice for motivation, the realization of the meaningful reading. There is a special place for the methodical ranking of the reading process, starting in school. Main requests of this reading, consist of the deep meaning of the subject, exploration of the idea, and other elements of the subject, implementation of the technique’s rules of the expressive reading, such as breathing, voice, diction, intonation, spelling, stoppages, logical emphasizes, emotional expressions, temper, timber, gesticulations, and mimic. There is also highlighted the fact that the used method comes from the pupils’ results and depends on the capability and level of the teacher, from the programming’s scale, the tools that are put into disposition, the age and the level of the pupils, and from the environment that the teacher creates during courses. At the end there are some practical guidelines for the realization of the expressive reading in the literature subject.

  8. Improve your reading

    CERN Document Server

    Fry, Ron

    2012-01-01

    Help your students discover the practical solution to their reading frustrations, with Improve Your Reading. Written by bestselling author and education advocate Ron Fry, this book avoids gimmicks and tricks in favor of proven strategies that will help your students better retain and comprehend what they've read in any textbook, in any course, at any academic level. Endlessly adaptable to each student's individual learning needs, the text focuses on fundamental skills students can carry beyond the classroom.

  9. Moderate glucose supply reduces hemolysis during systemic inflammation

    Directory of Open Access Journals (Sweden)

    Jägers J

    2018-03-01

    Full Text Available Johannes Jägers,1 Stephan Brauckmann,2 Michael Kirsch,1 Katharina Effenberger-Neidnicht1,3 1Institute of Physiological Chemistry, University Hospital Essen, Essen, Germany; 2Clinic for Anesthesiology and Intensive Care, University Hospital Essen, Essen, Germany; 3Institute of Physiological Chemistry, University Hospital Essen, Essen, Germany Background: Systemic inflammation alters energy metabolism. A sufficient glucose level, however, is most important for erythrocytes, since erythrocytes rely on glucose as sole source of energy. Damage to erythrocytes leads to hemolysis. Both disorders of glucose metabolism and hemolysis are associated with an increased risk of death. The objective of the study was to investigate the impact of intravenous glucose on hemolysis during systemic inflammation.Materials and methods: Systemic inflammation was accomplished in male Wistar rats by continuous lipopolysaccharide (LPS infusion (1 mg LPS/kg and h, 300 min. Sham control group rats received Ringer’s solution. Glucose was supplied moderately (70 mg glucose/kg and h or excessively (210 mg glucose/kg and h during systemic inflammation. Vital parameters (eg, systemic blood pressure as well as blood and plasma parameters (eg, concentrations of glucose, lactate and cell-free hemoglobin, and activity of lactate dehydrogenase were measured hourly. Clot formation was analyzed by thromboelastometry.Results: Continuous infusion of LPS led to a so-called post-aggression syndrome with disturbed electrolyte homeostasis (hypocalcemia, hyperkalemia, and hypernatremia, changes in hemodynamics (tachycardia and hypertension, and a catabolic metabolism (early hyperglycemia, late hypoglycemia, and lactate formation. It induced severe tissue injury (significant increases in plasma concentrations of transaminases and lactate dehydrogenase, alterations in blood coagulation (disturbed clot formation, and massive hemolysis. Both moderate and excessive glucose supply reduced LPS

  10. Reading disorders and dyslexia.

    Science.gov (United States)

    Hulme, Charles; Snowling, Margaret J

    2016-12-01

    We review current knowledge about the nature of reading development and disorders, distinguishing between the processes involved in learning to decode print, and the processes involved in reading comprehension. Children with decoding difficulties/dyslexia experience deficits in phoneme awareness, letter-sound knowledge and rapid automatized naming in the preschool years and beyond. These phonological/language difficulties appear to be proximal causes of the problems in learning to decode print in dyslexia. We review data from a prospective study of children at high risk of dyslexia to show that being at family risk of dyslexia is a primary risk factor for poor reading and children with persistent language difficulties at school entry are more likely to develop reading problems. Early oral language difficulties are strong predictors of later difficulties in reading comprehension. There are two distinct forms of reading disorder in children: dyslexia (a difficulty in learning to translate print into speech) and reading comprehension impairment. Both forms of reading problem appear to be predominantly caused by deficits in underlying oral language skills. Implications for screening and for the delivery of robust interventions for language and reading are discussed.

  11. On the possibility of nonfat frying using molten glucose.

    Science.gov (United States)

    Al-Khusaibi, Mohammed; Ahmad Tarmizi, Azmil Haizam; Niranjan, Keshavan

    2015-01-01

    Fried products impose a health concerns due to considerable amount of oil they contain. Production of snack foods with minimal oil content and good management of oil during frying to minimize the production of toxic compounds continue to be challenging aims. This paper aims to investigate the possibility of producing a fat-free food snack by replacing frying oil with a nonfat medium. Glucose was melted and its temperature was then brought to 185 °C and used to fry potato strips, to obtain a product referred here as glucose fries. The resulting product was compared with French fries prepared conventionally under conditions that resulted in similar final moisture content. The resulting products were also examined for crust formation, texture parameters, color development and glucose content. Stereo microscope images showed that similar crusts were formed in the glucose fries and French fries. Texture parameters were found to be similar for both products at 5 and 2 mm penetration depth. The maximum hardness at 2 mm penetration depth was also similar for both products, but different from cooked potato. The color development that characterized French fries was also observed in glucose fries. The glucose content in glucose fries was found to be twice the content of French fries, which is to be expected because glucose absorbed or adhered to the surface. In conclusion, glucose fries, with similar texture and color characteristics to that of French fries, can be prepared by using a nonfat frying medium. © 2014 Institute of Food Technologists®

  12. International consensus on use of continuous glucose monitoring

    DEFF Research Database (Denmark)

    Danne, Thomas; Nimri, Revital; Battelino, Tadej

    2017-01-01

    , have yet to be established. In February 2017, the Advanced Technologies & Treatments for Diabetes (ATTD) Congress convened an international panel of physicians, researchers, and individuals with diabetes who are expert in CGM technologies to address these issues. This article summarizes the ATTD...

  13. Developmental Relations Between Reading Comprehension and Reading Strategies

    NARCIS (Netherlands)

    Muijselaar, M.; Swart, N.M.; Steenbeek-Planting, E.G,.; Droop, M.; Verhoeven, L.; de Jong, P.F.

    2017-01-01

    We examined the developmental relations between knowledge of reading strategies and reading comprehension in a longitudinal study of 312 Dutch children from the beginning of fourth grade to the end of fifth grade. Measures for reading comprehension, reading strategies, reading fluency, vocabulary,

  14. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... around 4:00 a.m. to 5:00 a.m.). What are the Symptoms of Hyperglycemia? The signs and symptoms include the following: High blood glucose High levels of sugar in the urine Frequent urination Increased ...

  15. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... In Memory In Honor Become a Member En Español Type 1 Type 2 About Us Online Community ... Page Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical ...

  16. Low Blood Glucose (Hypoglycemia)

    Science.gov (United States)

    ... 24 hours after the activity. Drinking too much alcohol without enough food Alcohol makes it harder for your body to keep ... t eaten in a while. The effects of alcohol can also keep you from feeling the ... able to eat as much or keep food down, which can cause low blood glucose. Learn ...

  17. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term for high ... function (data) { $('#survey-errors').remove(); $('.survey-form .form-group .survey-alert-wrap').remove(); if (data.submitSurveyResponse.success == ' ...

  18. Blood Glucose Monitoring Devices

    Science.gov (United States)

    ... are below 100 mg/dL before meals and fasting and are less than 140 mg/dL two hours after meals. People with diabetes should consult their doctor or health care provider to set appropriate blood glucose goals. ...

  19. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor ... Chat Closed engagement en -- Have Type 2 Diabetes? - 2017-03-lwt2d-en.html Have Type 2 Diabetes? ...

  20. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease (Nephropathy) Gastroparesis Mental Health Step On Up Treatment & Care Blood Glucose Testing ... Pinterest Youtube Instagram Diabetes Stops Here Blog Online Community Site ... Day Prediabetes My Health Advisor Tools to Know Your Risk Diabetes Basics ...

  1. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Up Treatment & Care Blood Glucose Testing Medication Doctors, Nurses & More Oral Health & Hygiene Women A1C Insulin Pregnancy ... de Cure Women's Series Do-It-Yourself Fundraising Become a Volunteer American Diabetes Month® American Diabetes Association ...

  2. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Text Size: A A A Listen En Español Hyperglycemia (High Blood Glucose) Hyperglycemia is the technical term ... body can't use insulin properly. What Causes Hyperglycemia? A number of things can cause hyperglycemia: If ...

  3. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Research & Practice Ways to Give Close Are You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose ...

  4. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... You At Risk? Diabetes Basics Living with Diabetes Food & Fitness In My Community Advocacy Research & Practice Ways to Give Close Are You at Risk? Home ... work with your doctor to find the safest way for you to lower your blood glucose ... down on the amount of food you eat might also help. Work with your ...

  5. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... You at Risk? Home Prevention Diagnosing Diabetes and Learning About Prediabetes Type 2 Diabetes Risk Test Lower Your Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools To Know Your Risk Alert Day Diabetes Basics ...

  6. Hyperglycemia (High Blood Glucose)

    Medline Plus

    Full Text Available ... Risk Healthy Eating Overweight Smoking High Blood Pressure Physical Activity High Blood Glucose My Health Advisor Tools ... Complications DKA (Ketoacidosis) & Ketones Kidney Disease ... than planned or exercised less than planned. You have stress from an illness, such as a cold or flu. You have ...

  7. Effects of indigestible dextrin on glucose tolerance in rats.

    Science.gov (United States)

    Wakabayashi, S; Kishimoto, Y; Matsuoka, A

    1995-03-01

    A recently developed indigestible dextrin (IDex) was studied for its effects on glucose tolerance in male Sprague-Dawley rats. IDex is a low viscosity, water-soluble dietary fibre obtained by heating and enzyme treatment of potato starch. It has an average molecular weight of 1600. An oral glucose tolerance test was conducted with 8-week-old rats to evaluate the effects of IDex on the increase in plasma glucose and insulin levels after a single administration of various sugars (1.5 g/kg body weight). The increase in both plasma glucose and insulin levels following sucrose, maltose and maltodextrin loading was significantly reduced by IDex (0.15 g/kg body weight). This effect was not noted following glucose, high fructose syrup and lactose loading. To evaluate the effects of continual IDex ingestion on glucose tolerance, 5-week-old rats were kept for 8 weeks on a stock diet, a high sucrose diet or an IDex-supplemented high sucrose diet. An oral glucose (1.5 g/kg body weight) tolerance test was conducted in week 8. Increases in both plasma glucose and insulin levels following glucose loading were higher in the rats given a high sucrose diet than in the rats fed a stock diet. However, when IDex was included in the high sucrose diet, the impairment of glucose tolerance was alleviated. Moreover, IDex feeding also significantly reduced accumulation of body fat, regardless of changes in body weight. These findings suggest that IDex not only improves glucose tolerance following sucrose, maltose and maltodextrin loading but also stops progressive decrease in glucose tolerance by preventing a high sucrose diet from causing obesity.

  8. Extensive reading through the Internet: is it worth the while?

    Directory of Open Access Journals (Sweden)

    Juan Pino Silva

    2009-12-01

    Full Text Available Reading materials written in English is the prime goal of many reading programs around the world. Extensive reading (ER has for years aided new students at my institution to gradually acquire large vocabularies and other sub-skills that are needed to read fluently. To continue to do that effectively, a new scheme involving the use of internet - called w-ERP- was set in place in collaboration with the students. The main focus of this article is to describe the 3-phase, gradual process that led to the current design of the web-based ER scheme. The paper begins with a brief discussion of ER, reading on line (RO and self-directed learning as part of the rationale for the new scheme. Participants’ preliminary data on the benefits and potentials for learning to read and reading for learning other things are discussed.

  9. Business continuity

    International Nuclear Information System (INIS)

    Breunhoelder, Gert

    2002-01-01

    This presentation deals with the following keypoints: Information Technology (IT) Business Continuity and Recovery essential for any business; lessons learned after Sept. 11 event; Detailed planning, redundancy and testing being the key elements for probability estimation of disasters

  10. CSAF Reading List 2014

    Science.gov (United States)

    ... Undaunted Zero Dark Thirty 101109-F-RH756-737 Raptor's Reveille Featured Books Featured Films Featured Art House To House House To House by David Bellavia and John Bruning One of the great heroes of the Iraq War /McMillan/Switzler Read More... Fearless Book: Fearless by Eric Blehm Read More... Zero Dark Thirty Zero

  11. Reading Patterns Changing

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Modern life is changing the way people read April 23 was the 16th World Book and Copyright Day,also known as the World Book Day.Reading-related problems have once again attracted people’s attention.Today,living a life with an increasingly rapid pace,most people are

  12. VISION AND READING ABILITY.

    Science.gov (United States)

    MANGRUM, CHARLES T.

    SIGNIFICANT RESEARCH ON THE PHYSIOLOGICAL AND FUNCTIONAL ASPECTS OF VISION AND READING DISABILITY IS SURVEYED. CONCLUSIONS BASED ON THE LITERATURE IN THE FIELD ARE DISCUSSED. A BIBLIOGRAPHY OF 70 REFERENCES AND A GLOSSARY OF TERMS ARE APPENDED. A TABLE SUMMARIZING REFRACTIVE ERRORS AND EYE DEFECTS CONTRIBUTING TO READING DISABILITY IS INCLUDED.…

  13. Reading and Working Memory

    Science.gov (United States)

    Baddeley, Alan

    1984-01-01

    Outlines the concept of working memory, with particular reference to a hypothetical subcomponent, the articulatory loop. Discusses the role of the loop in fluent adult reading, then examines the reading performance of adults with deficits in auditory verbal memory, showing that a capacity to articulate is not necessary for the effective…

  14. How Knowledge Powers Reading

    Science.gov (United States)

    Lemov, Doug

    2017-01-01

    Recent research shows that reading comprehension relies heavily on prior knowledge. Far more than generic "reading skills" like drawing inferences, making predictions, and knowing the function of subheads, how well students learn from a nonfiction text depends on their background knowledge of the text's subject matter. And in a cyclical…

  15. Whole body glucose kinetics in type I diabetes studied with [6,6-2H] and [U-13C]-glucose and the artificial B-cell

    International Nuclear Information System (INIS)

    Darmaun, D.; Cirillo, D.; Koziet, J.; Chauvet, D.; Young, V.R.; Robert, J.J.

    1988-01-01

    Dynamic aspects of whole body glucose metabolism were assessed in ten young adult insulin-dependent (type I) diabetic men. Using a primed, continuous intravenous infusion of [6,6- 2 H]glucose and [U- 13 C]glucose, endogenous production, tissue uptake, carbon recycling, and oxidation of glucose were measured in the postabsorptive state. These studies were undertaken after blood glucose had been maintained overnight at 5.9 +/- 0.4 mmol/L (n = 10), and on another night at 10.5 +/- 0.4 mmol/L (n = 4) or 15.2 +/- 0.6 mmol/L (n = 6). In the normoglycemic state, endogenous glucose production averaged 2.15 +/- 0.13 mg x kg-1 x min-1. This value, as well as the rate of glucose carbon recycling (0.16 +/- 0.04 mg x kg-1 x min-1) and glucose oxidation (1.52 +/- 0.16 mg x kg-1 x min-1) are comparable to those found in nondiabetic controls. In the hyperglycemic states at 10 or 15 mmol/L, endogenous glucose production was increased by 11% (P less than .01) and 60% (P less than .01) compared to the normoglycemic states, respectively. Glucose carbon recycling contributed only a small percentage to this variation in glucose production (15% at the 15 mmol/L glucose level). This suggests that if gluconeogenesis participates in the increased glucose output, it is not dependent on a greater systemic supply of three-carbon precursors. The increased rate of glucose production in the hyperglycemic state was quantitatively offset by a rise in urinary glucose excretion. Glucose tissue uptake, as well as glucose oxidation, did not vary between normoglycemic and hyperglycemic states

  16. Continuous tokamaks

    International Nuclear Information System (INIS)

    Peng, Y.K.M.

    1978-04-01

    A tokamak configuration is proposed that permits the rapid replacement of a plasma discharge in a ''burn'' chamber by another one in a time scale much shorter than the elementary thermal time constant of the chamber first wall. With respect to the chamber, the effective duty cycle factor can thus be made arbitrarily close to unity minimizing the cyclic thermal stress in the first wall. At least one plasma discharge always exists in the new tokamak configuration, hence, a continuous tokamak. By incorporating adiabatic toroidal compression, configurations of continuous tokamak compressors are introduced. To operate continuous tokamaks, it is necessary to introduce the concept of mixed poloidal field coils, which spatially groups all the poloidal field coils into three sets, all contributing simultaneously to inducing the plasma current and maintaining the proper plasma shape and position. Preliminary numerical calculations of axisymmetric MHD equilibria in continuous tokamaks indicate the feasibility of their continued plasma operation. Advanced concepts of continuous tokamaks to reduce the topological complexity and to allow the burn plasma aspect ratio to decrease for increased beta are then suggested

  17. Science Fiction: Serious Reading, Critical Reading

    Science.gov (United States)

    Zigo, Diane; Moore, Michael T.

    2004-01-01

    Science fiction deserves a greater respect, serious and critical reading and a better place in high school literature classes. Some of the science fiction books by Isaac Asimov, Alfred Bester, Ray Bradbury and Octavia L. Butler and various activities for incorporating science fiction into the English language arts instruction classroom are…

  18. TEACHING READING USING MAGAZINE

    Directory of Open Access Journals (Sweden)

    Henny Uswatun Hasanah

    2013-11-01

    Full Text Available Teaching is a process of communication. It has to be created through the way of teaching and exchanging the message or information by every teacher and student. The message can be knowledge, skills, ideas, experiences, and many others. Through the process of communication, the people can receive the message or information. To avoid misunderstanding in the process of communication, media are needed in the process of teaching. Magazine can be other alternative as reading material in the classroom. Magazine as reading material has appeal for the students. To make the students get information from magazine, the teacher can ask the students to observe table of content and giving the students training to use it. Like, what is done on text book. Distinguishing informative reading material with fictive reading, important to know students in reading magazine. Like analyzing advertisements to detect propaganda.

  19. Reading and reading instruction for children from low-income and non-English-speaking households.

    Science.gov (United States)

    Lesaux, Nonie K

    2012-01-01

    Although most young children seem to master reading skills in the early grades of elementary school, many struggle with texts as they move through middle school and high school. Why do children who seem to be proficient readers in third grade have trouble comprehending texts in later grades? To answer this question, Nonie Lesaux describes what is known about reading development and instruction, homing in on research conducted with children from low-income and non-English-speaking homes. Using key insights from this research base, she offers two explanations. The first is that reading is a dynamic and multifaceted process that requires continued development if students are to keep pace with the increasing demands of school texts and tasks. The second lies in the role of reading assessment and instruction in U.S. schools. Lesaux draws a distinction between the "skills-based competencies" that readers need to sound out and recognize words and the "knowledge-based competencies" that include the conceptual and vocabulary knowledge necessary to comprehend a text's meaning. Although U.S. schools have made considerable progress in teaching skills-based reading competencies that are the focus of the early grades, most have made much less progress in teaching the knowledge-based competencies students need to support reading comprehension in middle and high school. These knowledge-based competencies are key sources of lasting individual differences in reading outcomes, particularly among children growing up in low-income and non-English-speaking households. Augmenting literacy rates, Lesaux explains, will require considerable shifts in the way reading is assessed and taught in elementary and secondary schools. First, schools must conduct comprehensive reading assessments that discern learners' (potential) sources of reading difficulties--in both skills-based and knowledge-based competencies. Second, educators must implement instructional approaches that offer promise for

  20. Glucose effectiveness in nondiabetic relatives

    DEFF Research Database (Denmark)

    Egede, M B; Henriksen, J-E; Durck, T T

    2014-01-01

    AIMS: Reduced glucose effectiveness is a predictor of future glucose tolerance in individuals with a family history of type 2 diabetes. We examined retrospectively at 10 years in normoglycemic relatives of diabetic subjects (RELs) the pathophysiological role of glucose effectiveness in the develo...

  1. In vivo continuous and simultaneous monitoring of brain energy substrates with a multiplex amperometric enzyme-based biosensor device.

    Science.gov (United States)

    Cordeiro, C A; de Vries, M G; Ngabi, W; Oomen, P E; Cremers, T I F H; Westerink, B H C

    2015-05-15

    Enzyme-based amperometric biosensors are widely used for monitoring key biomarkers. In experimental neuroscience there is a growing interest in in vivo continuous and simultaneous monitoring of metabolism-related biomarkers, like glucose, lactate and pyruvate. The use of multiplex biosensors will provide better understanding of brain energy metabolism and its role in neuropathologies such as diabetes, ischemia, and epilepsy. We have developed and characterized an implantable multiplex microbiosensor device (MBD) for simultaneous and continuous in vivo monitoring of glucose, lactate, and pyruvate. First, we developed and characterized amperometric microbiosensors for monitoring lactate and pyruvate. In vitro evaluation allowed us to choose the most suitable biosensors for incorporation into the MBD, along with glucose and background biosensors. Fully assembled MBDs were characterized in vitro. The calculated performance parameters (LOD, LR, LRS, IMAX and appKM) showed that the multiplex MBD was highly selective and sensitive (LRS≥100 nA/mM) for each analyte and within an adequate range for in vivo application. Finally, MBDs were implanted in the mPFC of anesthetized adult male Wistar rats for in vivo evaluation. Following an equilibration period, baseline brain levels of glucose (1.3±0.2 mM), lactate (1.5±0.4 mM) and pyruvate (0.3±0.1 mM) were established. Subsequently, the MBDs recorded the responses of the animals when submitted to hyperglycemic (40% glucose i.v.) and hypoglycemic (5 U/kg insulin i.v.) challenges. Afterwards, MBDs were recalibrated to convert electrochemical readings into accurate substrate concentrations and to assess biofouling. The presented MBD can monitor simultaneously multiple biomarkers in vivo. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Continuous Dropout.

    Science.gov (United States)

    Shen, Xu; Tian, Xinmei; Liu, Tongliang; Xu, Fang; Tao, Dacheng

    2017-10-03

    Dropout has been proven to be an effective algorithm for training robust deep networks because of its ability to prevent overfitting by avoiding the co-adaptation of feature detectors. Current explanations of dropout include bagging, naive Bayes, regularization, and sex in evolution. According to the activation patterns of neurons in the human brain, when faced with different situations, the firing rates of neurons are random and continuous, not binary as current dropout does. Inspired by this phenomenon, we extend the traditional binary dropout to continuous dropout. On the one hand, continuous dropout is considerably closer to the activation characteristics of neurons in the human brain than traditional binary dropout. On the other hand, we demonstrate that continuous dropout has the property of avoiding the co-adaptation of feature detectors, which suggests that we can extract more independent feature detectors for model averaging in the test stage. We introduce the proposed continuous dropout to a feedforward neural network and comprehensively compare it with binary dropout, adaptive dropout, and DropConnect on Modified National Institute of Standards and Technology, Canadian Institute for Advanced Research-10, Street View House Numbers, NORB, and ImageNet large scale visual recognition competition-12. Thorough experiments demonstrate that our method performs better in preventing the co-adaptation of feature detectors and improves test performance.

  3. Dietary fructose and glucose differentially affect lipid and glucose homeostasis.

    Science.gov (United States)

    Schaefer, Ernst J; Gleason, Joi A; Dansinger, Michael L

    2009-06-01

    Absorbed glucose and fructose differ in that glucose largely escapes first-pass removal by the liver, whereas fructose does not, resulting in different metabolic effects of these 2 monosaccharides. In short-term controlled feeding studies, dietary fructose significantly increases postprandial triglyceride (TG) levels and has little effect on serum glucose concentrations, whereas dietary glucose has the opposite effects. When dietary glucose and fructose have been directly compared at approximately 20-25% of energy over a 4- to 6-wk period, dietary fructose caused significant increases in fasting TG and LDL cholesterol concentrations, whereas dietary glucose did not, but dietary glucose did increase serum glucose and insulin concentrations in the postprandial state whereas dietary fructose did not. When fructose at 30-60 g ( approximately 4-12% of energy) was added to the diet in the free-living state, there were no significant effects on lipid or glucose biomarkers. Sucrose and high-fructose corn syrup (HFCS) contain approximately equal amounts of fructose and glucose and no metabolic differences between them have been noted. Controlled feeding studies at more physiologic dietary intakes of fructose and glucose need to be conducted. In our view, to decrease the current high prevalence of obesity, dyslipidemia, insulin resistance, and diabetes, the focus should be on restricting the intake of excess energy, sucrose, HFCS, and animal and trans fats and increasing exercise and the intake of vegetables, vegetable oils, fish, fruit, whole grains, and fiber.

  4. No interactions between previously associated 2-hour glucose gene variants and physical activity or BMI on 2-hour glucose levels

    DEFF Research Database (Denmark)

    Scott, Robert A; Chu, Audrey Y; Grarup, Niels

    2012-01-01

    to determine 2-h glucose levels is unknown. We meta-analyzed single nucleotide polymorphism (SNP) × BMI and SNP × physical activity (PA) interaction regression models for five SNPs previously associated with 2-h glucose levels from up to 22 studies comprising 54,884 individuals without diabetes. PA levels were......Gene-lifestyle interactions have been suggested to contribute to the development of type 2 diabetes. Glucose levels 2 h after a standard 75-g glucose challenge are used to diagnose diabetes and are associated with both genetic and lifestyle factors. However, whether these factors interact...... dichotomized, with individuals below the first quintile classified as inactive (20%) and the remainder as active (80%). BMI was considered a continuous trait. Inactive individuals had higher 2-h glucose levels than active individuals (ß = 0.22 mmol/L [95% CI 0.13-0.31], P = 1.63 × 10(-6)). All SNPs were...

  5. Helping the Underachiever in Reading. ERIC Digest.

    Science.gov (United States)

    Quatroche, Diana J.

    Noting that the development of effective intervention programs and instructional strategies for the struggling or underachieving reader continues to be a topic of concern, this Digest first reviews the current status of reading performance, based on the 1998 National Assessment of Educational Progress. It then reports on the importance of early…

  6. Forecasting Reading Anxiety for Promoting English-Language Reading Performance Based on Reading Annotation Behavior

    Science.gov (United States)

    Chen, Chih-Ming; Wang, Jung-Ying; Chen, Yong-Ting; Wu, Jhih-Hao

    2016-01-01

    To reduce effectively the reading anxiety of learners while reading English articles, a C4.5 decision tree, a widely used data mining technique, was used to develop a personalized reading anxiety prediction model (PRAPM) based on individual learners' reading annotation behavior in a collaborative digital reading annotation system (CDRAS). In…

  7. Continuity theory

    CERN Document Server

    Nel, Louis

    2016-01-01

    This book presents a detailed, self-contained theory of continuous mappings. It is mainly addressed to students who have already studied these mappings in the setting of metric spaces, as well as multidimensional differential calculus. The needed background facts about sets, metric spaces and linear algebra are developed in detail, so as to provide a seamless transition between students' previous studies and new material. In view of its many novel features, this book will be of interest also to mature readers who have studied continuous mappings from the subject's classical texts and wish to become acquainted with a new approach. The theory of continuous mappings serves as infrastructure for more specialized mathematical theories like differential equations, integral equations, operator theory, dynamical systems, global analysis, topological groups, topological rings and many more. In light of the centrality of the topic, a book of this kind fits a variety of applications, especially those that contribute to ...

  8. The Path to Competence: A Lifespan Developmental Perspective on Reading

    Science.gov (United States)

    Alexander, Patricia A.

    2012-01-01

    The purpose of this document is to present a developmental model of reading that encompasses changes across the lifespan. The need for such a lifespan orientation toward reading within our educational institutions is great. Until we adopt this lifelong perspective, we continue to run the risk of turning out undeveloped, unmotivated, and uncritical…

  9. Manioc alcohol by continuous fermentation

    Energy Technology Data Exchange (ETDEWEB)

    Del Bianco, V; de Queiroz Araujo, N; Miceli, A; Souza e Silva, P C; da Silva Burle, J A

    1976-01-01

    EtOH was produced from dry cassava meal by first obtaining a glucose syrup by enzymic action, then fermenting the syrup with yeast. Bacillus subtilis amylase and Aspergillus awamori amyloglucosidase were prepared by growing the organisms on cassava meal. Both enzymes were used to saccharify the cassava starch to syrup. Saccharomyces cervisiae ATCC 1133 was then used in a continuous process to produce EtOH.

  10. Glucose production for cellulose

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, S; Karube, I

    1977-04-16

    Glucose was produced from cellulose by passing a cellulose solution through a column of an immobilized cellulase which was prepared by coating an inorganic carrier such as macadam or stainless steel beads with collagen containing the cellulase. Thus, 4 mL of 5% cellulase T-AP (60,000 units/g) solution was dissolved in 100 g of 0.9% collagen solution and the solution mixed with 60 g of macadam (diam. = 0.5 to 1.5 mm) and stirred for 10 min. The treated beads were dried in air at 10/sup 0/ to yield an immobilized enzyme retaining 64% of its activity. Through a column (0.8 x 20 cm) packed with 3 g of the immobilized enzyme, 100 mL of 0.33% Avicel SF solution was circulated at 26.4 mL/min at 30/sup 0/ for 60 h. The Avicel SF conversion to glucose was 23%.

  11. Chapter 10: Glucose control: insulin therapy*

    African Journals Online (AJOL)

    Insulin and its analogues lower blood glucose by stimulating peripheral glucose uptake, especially by skeletal muscle and fat, and by inhibiting hepatic glucose production. Insulin inhibits ... control on 2 or 3 oral glucose lowering drugs.

  12. Is Low Blood Glucose (Hypoglycemia) Dangerous?

    Science.gov (United States)

    ... pills. In general, hypoglycemia is defined as a blood glucose level below 70 mg/dl. Low blood glucose is ... glucose. Always carry carbohydrate foods for treatment. Check blood glucose levels again in 15 minutes, and repeat treatment if ...

  13. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard

    1984-01-01

    The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent...... of the 92 measurements obtained with the hypocount B were within +/- 20% of the laboratory glucose values. Using haemo-glucotest 1-44 strips, 74% of the readings were within +/- 20% of the reference laboratory values. For values below 5.5 mmol/l, there was a tendency for results to be too low, with 77......% of the readings below laboratory values -20%. All situations with severe hypoglycaemia were detected with both strips. The study also demonstrates the ineffectiveness of s.c. insulin regimens during surgery. Only 47% of the measured blood glucose values were within the range of 5.5-10 mmol/l and two of ten...

  14. A data driven nonlinear stochastic model for blood glucose dynamics.

    Science.gov (United States)

    Zhang, Yan; Holt, Tim A; Khovanova, Natalia

    2016-03-01

    The development of adequate mathematical models for blood glucose dynamics may improve early diagnosis and control of diabetes mellitus (DM). We have developed a stochastic nonlinear second order differential equation to describe the response of blood glucose concentration to food intake using continuous glucose monitoring (CGM) data. A variational Bayesian learning scheme was applied to define the number and values of the system's parameters by iterative optimisation of free energy. The model has the minimal order and number of parameters to successfully describe blood glucose dynamics in people with and without DM. The model accounts for the nonlinearity and stochasticity of the underlying glucose-insulin dynamic process. Being data-driven, it takes full advantage of available CGM data and, at the same time, reflects the intrinsic characteristics of the glucose-insulin system without detailed knowledge of the physiological mechanisms. We have shown that the dynamics of some postprandial blood glucose excursions can be described by a reduced (linear) model, previously seen in the literature. A comprehensive analysis demonstrates that deterministic system parameters belong to different ranges for diabetes and controls. Implications for clinical practice are discussed. This is the first study introducing a continuous data-driven nonlinear stochastic model capable of describing both DM and non-DM profiles. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  15. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring.

    Science.gov (United States)

    Chen, Yihao; Lu, Siyuan; Zhang, Shasha; Li, Yan; Qu, Zhe; Chen, Ying; Lu, Bingwei; Wang, Xinyan; Feng, Xue

    2017-12-01

    Currently, noninvasive glucose monitoring is not widely appreciated because of its uncertain measurement accuracy, weak blood glucose correlation, and inability to detect hyperglycemia/hypoglycemia during sleep. We present a strategy to design and fabricate a skin-like biosensor system for noninvasive, in situ, and highly accurate intravascular blood glucose monitoring. The system integrates an ultrathin skin-like biosensor with paper battery-powered electrochemical twin channels (ETCs). The designed subcutaneous ETCs drive intravascular blood glucose out of the vessel and transport it to the skin surface. The ultrathin (~3 μm) nanostructured biosensor, with high sensitivity (130.4 μA/mM), fully absorbs and measures the glucose, owing to its extreme conformability. We conducted in vivo human clinical trials. The noninvasive measurement results for intravascular blood glucose showed a high correlation (>0.9) with clinically measured blood glucose levels. The system opens up new prospects for clinical-grade noninvasive continuous glucose monitoring.

  16. Entry rates and recycling of glucose in buffalo calves fed on urea molasses liquid diet

    Energy Technology Data Exchange (ETDEWEB)

    Varma, A; Singh, U B; Verma, D N; Ranjhan, S K [Indian Veterinary Research Inst., Izatnagar. Div. of Animal Nutrition

    1974-12-01

    Entry rates of glucose have been measured in buffalo calves by using a dual-isotope dilution method based on continuous infusion of (U-/sup 14/C)D-glucose and (6-/sup 3/H)D-glucose into the blood at a precise controlled rate for 540 min. After 5 h a plateau was obtained in the specific radioactivity of the plasma glucose from which glucose synthesis and entry rates were calculated. The average entry rates of glucose were 112 and 145 mg/min measured by /sup 14/C and /sup 3/H labelled glucose respectively. About 23 percent of the glucose carbon was recycled in the pool. The average recycling rate was 33 mg/min.

  17. Entry rates and recycling of glucose in buffalo calves fed on urea molasses liquid diet

    International Nuclear Information System (INIS)

    Varma, Arun; Singh, U.B.; Verma, D.N.; Ranjhan, S.K.

    1974-01-01

    Entry rates of glucose have been measured in buffalo calves by using a dual-isotope dilution method based on continuous infusion of (U- 14 C)D-glucose and (6- 3 H)D-glucose into the blood at a precise controlled rate for 540 min. After 5 h a plateau was obtained in the specific radioactivity of the plasma glucose from which glucose synthesis and entry rates were calculated. The average entry rates of glucose were 112 and 145 mg/min measured by 14 C and 3 H labelled glucose respectively. About 23 percent of the glucose carbon was recycled in the pool. The average recycling rate was 33 mg/min. (author)

  18. Glucose-Sensitive Hydrogel Optical Fibers Functionalized with Phenylboronic Acid.

    Science.gov (United States)

    Yetisen, Ali K; Jiang, Nan; Fallahi, Afsoon; Montelongo, Yunuen; Ruiz-Esparza, Guillermo U; Tamayol, Ali; Zhang, Yu Shrike; Mahmood, Iram; Yang, Su-A; Kim, Ki Su; Butt, Haider; Khademhosseini, Ali; Yun, Seok-Hyun

    2017-04-01

    Hydrogel optical fibers are utilized for continuous glucose sensing in real time. The hydrogel fibers consist of poly(acrylamide-co-poly(ethylene glycol) diacrylate) cores functionalized with phenylboronic acid. The complexation of the phenylboronic acid and cis-diol groups of glucose enables reversible changes of the hydrogel fiber diameter. The analyses of light propagation loss allow for quantitative glucose measurements within the physiological range. © 2017 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Reading and company

    DEFF Research Database (Denmark)

    Kuzmičová, Anežka; Dias, Patrícia; Vogrinčič Čepič, Ana

    2017-01-01

    in the environment where one engages in individual silent reading. The primary goal of the study was to explore the role and possible associations of a number of variables (text type, purpose, device) in selecting generic (e.g. indoors vs outdoors) as well as specific (e.g. home vs library) reading environments....... Across all six samples included in the study, participants spontaneously attested to varied, and partly surprising, forms of sensitivity to company and social space in their daily efforts to align body with mind for reading. The article reports these emergent trends and discusses their potential...

  20. Impaired glucose tolerance in patients with amyotrophic lateral sclerosis.

    Science.gov (United States)

    Pradat, Pierre-Francois; Bruneteau, Gaelle; Gordon, Paul H; Dupuis, Luc; Bonnefont-Rousselot, Dominique; Simon, Dominique; Salachas, Francois; Corcia, Philippe; Frochot, Vincent; Lacorte, Jean-Marc; Jardel, Claude; Coussieu, Christiane; Le Forestier, Nadine; Lacomblez, Lucette; Loeffler, Jean-Philippe; Meininger, Vincent

    2010-01-01

    Our objectives were to analyse carbohydrate metabolism in a series of ALS patients and to examine potential association with parameters of lipid metabolism and clinical features. Glucose tolerance was assessed by the oral glucose tolerance test in 21 non-diabetic ALS patients and compared with 21 age- and sex-matched normal subjects. Lipids and lactate/pyruvate ratio, levels of pro-inflammatory cytokines (tumour necrosis factor-alpha and interleukin-6) and adipocytokines (leptin and adiponectin) were also measured in ALS patients. Mann-Whitney U-tests analysed continuous data and Fisher's exact tests assessed categorical data. Blood glucose determined 120 min after the glucose bolus was significantly higher in patients with ALS (7.41 mmol/l+/-1.68) compared to controls (6.05+/-1.44, p=0.006). ALS patients with impaired glucose tolerance (IGT) according to WHO criteria (n=7, 33%) were more likely to have elevated free fatty acids (FFA) levels compared to patients with normal glucose tolerance (0.77 nmol/l+/-0.30 vs. 0.57+/-0.19, p=0.04). IGT was not associated with disease duration or severity. In conclusion, patients with ALS show abnormal glucose tolerance that could be associated with increased FFA levels, a key determinant of insulin resistance. The origin of glucose homeostasis abnormalities in ALS may be multifactorial and deserves further investigation.

  1. Continuation calculus

    NARCIS (Netherlands)

    Geron, B.; Geuvers, J.H.; de'Liguoro, U.; Saurin, A.

    2013-01-01

    Programs with control are usually modeled using lambda calculus extended with control operators. Instead of modifying lambda calculus, we consider a different model of computation. We introduce continuation calculus, or CC, a deterministic model of computation that is evaluated using only head

  2. Enhanced muscle glucose metabolism after exercise

    DEFF Research Database (Denmark)

    Richter, Erik; Garetto, L P; Goodman, M N

    1984-01-01

    Studies in the rat suggest that after voluntary exercise there are two phases of glycogen repletion in skeletal muscle (preceding study). In phase I glucose utilization and glycogen synthesis are enhanced both in the presence and absence of insulin, whereas in phase II only the increase in the pr......Studies in the rat suggest that after voluntary exercise there are two phases of glycogen repletion in skeletal muscle (preceding study). In phase I glucose utilization and glycogen synthesis are enhanced both in the presence and absence of insulin, whereas in phase II only the increase...... in the stimulated leg closely mimicked that observed previously after voluntary exercise on a treadmill. With no insulin added to the perfusate, glucose incorporation into glycogen was markedly enhanced in muscles that were glycogen depleted as were the uptake of 2-deoxyglucose and 3-O-methylglucose. Likewise......, the stimulation of these processes by insulin was enhanced and continued to be so 2 h later when the muscles of the stimulated leg had substantially repleted their glycogen stores. The results suggest that the increases in insulin-mediated glucose utilization and glycogen synthesis in muscle after exercise...

  3. Glucose-dependent insulinotropic polypeptide

    DEFF Research Database (Denmark)

    Christensen, Mikkel Bring

    2016-01-01

    was to investigate how the blood glucose level affects the glucagon and insulin responses to GIP in healthy subjects (Study 1) and patients with Type 2 diabetes (Study 2), and more specifically to investigate the effects of GIP and GLP-1 at low blood glucose in patients with Type 1 diabetes without endogenous...... as his own control. Interventions were intravenous administration of hormones GIP, GLP-1 and placebo (saline) during different blood glucose levels maintained (clamped) at a certain level. The end-points were plasma concentrations of glucagon and insulin as well as the amount of glucose used to clamp...... the blood glucose levels. In Study 3, we also used stable glucose isotopes to estimate the endogenous glucose production and assessed symptoms and cognitive function during hypoglycaemia. The results from the three studies indicate that GIP has effects on insulin and glucagon responses highly dependent upon...

  4. Glucose-dependent Insulinotropic Polypeptide

    DEFF Research Database (Denmark)

    Christensen, Mikkel B; Calanna, Salvatore; Holst, Jens Juul

    2014-01-01

    CONTEXT: Patients with type 2 diabetes mellitus (T2DM) have clinically relevant disturbances in the effects of the hormone glucose-dependent insulinotropic polypeptide (GIP). OBJECTIVE: We aimed to evaluate the importance of the prevailing plasma glucose levels for the effect of GIP on responses......: During fasting glycemia (plasma glucose ∼8 mmol/L), GIP elicited significant increments in both insulin and glucagon levels, resulting in neutral effects on plasma glucose. During insulin-induced hypoglycemia (plasma glucose ∼3 mmol/L), GIP elicited a minor early-phase insulin response and increased...... glucagon levels during the initial 30 minutes, resulting in less glucose needed to be infused to maintain the clamp (29 ± 8 vs 49 ± 12 mg × kg(-1), P glucose ∼12 mmol/L), GIP augmented insulin secretion throughout the clamp, with slightly less glucagon...

  5. Thermoinactivation Mechanism of Glucose Isomerase

    Science.gov (United States)

    Lim, Leng Hong; Saville, Bradley A.

    In this article, the mechanisms of thermoinactivation of glucose isomerase (GI) from Streptomyces rubiginosus (in soluble and immobilized forms) were investigated, particularly the contributions of thiol oxidation of the enzyme's cysteine residue and a "Maillard-like" reaction between the enzyme and sugars in high fructose corn syrup (HFCS). Soluble GI (SGI) was successfully immobilized on silica gel (13.5 μm particle size), with an activity yield between 20 and 40%. The immobilized GI (IGI) has high enzyme retention on the support during the glucose isomerization process. In batch reactors, SGI (half-life =145 h) was more stable than IGI (half-life=27 h) at 60°C in HFCS, whereas at 80°C, IGI (half-life=12 h) was more stable than SGI (half-life=5.2 h). IGI was subject to thiol oxidation at 60°C, which contributed to the enzyme's deactivation. IGI was subject to thiol oxidation at 80°C, but this did not contribute to the deactivation of the enzyme. SGI did not undergo thiol oxidation at 60°C, but at 80°C SGI underwent severe precipitation and thiol oxidation, which caused the enzyme to deactivate. Experimental results show that immobilization suppresses the destablizing effect of thiol oxidation on GI. A "Maillard-like" reaction between SGI and the sugars also caused SGI thermoinactivation at 60, 70, and 80°C, but had minimal effect on IGI. At 60 and 80°C, IGI had higher thermostability in continuous reactors than in batch reactors, possibily because of reduced contact with deleterious compounds in HFCS.

  6. A fine pointed glucose oxidase immobilized electrode for low-invasive amperometric glucose monitoring.

    Science.gov (United States)

    Li, Jiang; Koinkar, Pankaj; Fuchiwaki, Yusuke; Yasuzawa, Mikito

    2016-12-15

    A low invasive type glucose sensor, which has a sensing region at the tip of a fine pointed electrode, was developed for continuous glucose monitoring. Platinum-iridium alloy electrode with a surface area of 0.045mm(2) was settled at the middle of pointed PEEK (Polyetheretherketone) tubing and was employed as sensing electrode. Electrodeposition of glucose oxidase in the presence of surfactant, Triton X-100, was performed for high-density enzyme immobilization followed by the electropolymerization of o-phenylenediamine for the formation of functional entrapping and permselective polymer membrane. Ag/AgCl film was coated on the surface of PEEK tubing as reference electrode. Amperometric responses of the prepared sensors to glucose were measured at a potential of 0.60V (vs. Ag/AgCl). The prepared electrode showed the sensitivity of 2.55μA/cm(2) mM with high linearity of 0.9986, within the glucose concentration range up to 21mM. The detection limit (S/N=3) was determined to be 0.11mM. The glucose sensor properties were evaluated in phosphate buffer solution and in vivo monitoring by the implantation of the sensors in rabbit, while conventional needle type sensors as a reference were used. The results showed that change in output current of the proposed sensor fluctuated similar with one in output current of the conventional needle type sensors, which was also in similar accordance with actual blood sugar level measured by commercially glucose meter. One-point calibration method was used to calibrate the sensor output current. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Understanding Blood Pressure Readings

    Science.gov (United States)

    ... Venous Thromboembolism Aortic Aneurysm More Understanding Blood Pressure Readings Updated:Jun 1,2018 What do your blood ... and Live Our Interactive Cardiovascular Library has detailed animations and illustrations to help you learn about conditions, ...

  8. Reading the Tourist Guidebook

    DEFF Research Database (Denmark)

    Therkelsen, Anette; Sørensen, Anders

    2005-01-01

    of information sought, amount of information read and level of involvement displayed, indicating a three-pronged typology of guidebook readers. The guidebook reader typology thus constructed may be regarded as a first step in understanding the effect of guidebooks on tourists’ behaviour and their experience......This article investigates tourists’ ways of reading their guidebooks on the basis of qualitative interviews with tourists visiting Copenhagen, Denmark. Tourist guidebooks have only been dealt with sporadically by tourism scholars. The relatively few studies that focus on guidebooks either present...... a historical perspective on the guidebook or centre on content analyses of place representation, whereas virtually no research exists on the way in which tourists read and use their guidebooks. This study reveals that tourists read the same guidebooks in a number of different ways regarding types...

  9. What Are Reading Disorders?

    Science.gov (United States)

    ... and language-based learning disabilities are commonly called dyslexia . These disorders are present from a young age ... information about these problems. Types of Reading Disorders Dyslexia is a brain-based type of learning disability ...

  10. Textbook Reading Levels

    Science.gov (United States)

    Hopkins, Charles R.; Kim, Paul Y.

    1974-01-01

    Since the reading abilities of general business students vary from one individual to the next, the author's report on the readability of three general business textbooks to guide business teachers in their selection of textbooks. (AG)

  11. Sequence Read Archive (SRA)

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Sequence Read Archive (SRA) stores raw sequencing data from the next generation of sequencing platforms including Roche 454 GS System®, Illumina Genome...

  12. Reading-Boxing Class

    Science.gov (United States)

    Kravitz, Richard; Shapiro, Marvin

    1969-01-01

    The physical education department of the Pennsylvania Advancement School of Philadelphia has established a reading and communication skill project that uses the appeal of sports to help students improve their basic skills. (Author)

  13. Continuation calculus

    Directory of Open Access Journals (Sweden)

    Bram Geron

    2013-09-01

    Full Text Available Programs with control are usually modeled using lambda calculus extended with control operators. Instead of modifying lambda calculus, we consider a different model of computation. We introduce continuation calculus, or CC, a deterministic model of computation that is evaluated using only head reduction, and argue that it is suitable for modeling programs with control. It is demonstrated how to define programs, specify them, and prove them correct. This is shown in detail by presenting in CC a list multiplication program that prematurely returns when it encounters a zero. The correctness proof includes termination of the program. In continuation calculus we can model both call-by-name and call-by-value. In addition, call-by-name functions can be applied to call-by-value results, and conversely.

  14. Reading Popular Islamic Literature: Continuity And Change In Indonesian Literature

    Directory of Open Access Journals (Sweden)

    Mohammad Rokib

    2016-01-01

    Full Text Available In the last few years, literature on Islamic themes has become increasingly popular in Indonesia. It is commonly categorized as Islamic literature identified by Islamic texts and symbols on the book cover and its content. The literary works have been popular as reflected in the record sales figures. Previously, some literary works dealing with Islamic themes failed to gain public attention. Interestingly, those works are not mentioned by people as Islamic literature. This paper aims to discuss some questions on why are some literary works on Islamic theme mentioned as Islamic while others are not? Is there Islamic literature within Indonesian literature? What are the differences between Islamic literature and kitab literature (sastra kitab written by Muslim scholars in the Malay world? By exploring the social context of reader responses toward selected literary works on Islam, this study reveals that the label of Islamic literature is created to confront opposite themes in Indonesian literature. The term Islamic literature remains a problematic and debatable issue related to literature based on Islamic themes in both old and modern Indonesian literature.

  15. Developing New Reading Assessments to Promote Beginning Reading in Singapore

    Science.gov (United States)

    Koh, Kim H.; Paris, Scott G.

    2011-01-01

    Effective reading instruction and intervention are rooted in effective assessments of children's developing skills in reading. The article aims to describe the development of new reading assessments to help promote beginning reading in Singapore primary schools. We begin with an introduction to the educational landscape and policies before…

  16. Reading Every Single Day: A Journey to Authentic Reading

    Science.gov (United States)

    Hudson, Alida K.; Williams, Joan A.

    2015-01-01

    This article details one teacher's implementation of reading workshop in her second grade classroom. She provided a framework for authentic reading using the five components of reading workshop: time, choice, response, community, and structure. She found that reading workshop is a highly effective practice for not only increasing students'…

  17. Exploring Students' Reading Profiles to Guide a Reading Intervention Programme

    Science.gov (United States)

    Boakye, Naomi A. N. Y.

    2017-01-01

    There have been a number of studies on reading interventions to improve students' reading proficiency, yet the majority of these interventions are undertaken with the assumption that students' reading challenges are obvious and generic in nature. The interventions do not take into consideration the diversity in students' reading backgrounds and…

  18. "Read the Text, as if!"The Reading Retention Strategy

    Science.gov (United States)

    Divoll, Kent; Browning, Sandra

    2013-01-01

    Students do not always read what is expected in college courses (Berry, Cook, Hill, & Stevens, 2010; Phillips & Phillips, 2007; Sikorski et al., 2002) or they read to cram for an exam or quiz (Clump, Bauer, & Bradley, 2004). The Reading Retention Strategy (RRS) is designed to motivate students to read and assist students in…

  19. Child-centered reading intervention: See, talk, dictate, read, write!

    Directory of Open Access Journals (Sweden)

    Muhammet BAŞTUĞ

    2016-06-01

    Full Text Available Poor reading achievement of children in elementary schools has been one of the major concerns in education. The aim of this study is to examine the effectiveness of a child-centered reading intervention in eliminating the reading problems of a student with poor reading achievement. The research was conducted with a student having difficulty in reading. A reading intervention was designed that targeted multiple areas of reading and aimed to improve reading skills through the use of multiple strategies. This intervention is child-centered and includes visual aids, talking, dictating, reading and writing stages. The study was performed in 35 sessions consisting of stages of a single sentence (5 sessions, two sentences (5 sessions, three sentences (20 sessions and the text stage (5 sessions. The intervention sessions were audio-taped. These recordings and the written responses to the reading comprehension questions provided the data for analysis. The findings on the reading intervention revealed positive outcomes. The student exhibited certain improvements at the levels of reading, reading rate and reading comprehension. These results were discussed in the literature and the findings suggest that child-centered reading strategies such as talking, dictating and writing should be the main focus of instruction for students with low reading literacy achievement to enable these students to meet the demands of the curriculum.

  20. IMPROVING STUDENTS’ READING COMPREHENSION THROUGH IINTERACTIVE READ-ALOUD TECHNIQUE

    Directory of Open Access Journals (Sweden)

    Edi Santoso

    2015-10-01

    Full Text Available Abstract: The present study, entitled Improving Students’ Reading Comprehension through Interactive Read-Aloud, attempts to unlock problems found in teaching and reading comprehension through interactive read-aloud in a Senior High School of Sport (SMAN Olah Raga Lampung, in Metro. The findings revealed that students’ reading comprehension improved through interactive read-aloud. The improvement can be seen from the increase of test results, meaning construction, and motivation. The process of reading activities showed that the teacher’s gesture and body language, 20 questions, explain and guess activities were proven to help the students construct meaning from the given texts. In addition, interactive read-aloud is effective to boost students’ motivation to comprehend the texts.   Key words: Reading comprehension, interactive read-aloud.

  1. A randomised trial of glucose tablets to aid smoking cessation.

    Science.gov (United States)

    West, Robert; May, Sylvia; McEwen, Andy; McRobbie, Hayden; Hajek, Peter; Vangeli, Eleni

    2010-01-01

    Oral glucose has been found to decrease tobacco craving among abstaining smokers. One study has demonstrated an effect of glucose on short-term abstinence. There is a need to examine any long-term benefit of glucose on abstinence. To assess whether glucose tablets improve 6-month continuous abstinence rates compared with low-calorie placebo tablets. Smokers attempting to stop (n = 928) were randomised to receive glucose or sorbitol (placebo) in a double-blind placebo-controlled trial. All participants received group-based psychological support, and approximately half (n = 474) received nicotine replacement therapy (NRT), buproprion, or both. Smokers were seen weekly for 5 weeks and used tablets ad libitum, with a recommended minimum of 12 per day. Participants were recruited through general practitioner referral, word of mouth, and advertising. The participants were 38% male, smoked an average of 23.5 cigarettes per day, and had a mean age of 44 years. There were no significant pretreatment differences between groups. The primary outcome measure was continuous, CO-verified abstinence from the target quit date for 6 months. No significant effect of glucose tablets on abstinence was found (14.6% vs 13.4% abstinence in the glucose and placebo groups, respectively). However, there was a significant interaction with a glucose effect observed in smokers also receiving other medication (18.2% vs 12.6%, p < 0.05) but not otherwise (10.7% vs 14.3% ; p < 0.05 for the interaction). No significant effect of glucose tablets over and above sweet tasting tablets could be detected overall, but the possibility of an effect as an adjunct to NRT or bupropion merits further investigation.

  2. Translating HbA1c measurements into estimated average glucose values in pregnant women with diabetes

    DEFF Research Database (Denmark)

    Law, Graham R; Gilthorpe, Mark S; Secher, Anna L

    2017-01-01

    AIMS/HYPOTHESIS: This study aimed to examine the relationship between average glucose levels, assessed by continuous glucose monitoring (CGM), and HbA1c levels in pregnant women with diabetes to determine whether calculations of standard estimated average glucose (eAG) levels from HbA1c measureme...

  3. Robust continuous clustering.

    Science.gov (United States)

    Shah, Sohil Atul; Koltun, Vladlen

    2017-09-12

    Clustering is a fundamental procedure in the analysis of scientific data. It is used ubiquitously across the sciences. Despite decades of research, existing clustering algorithms have limited effectiveness in high dimensions and often require tuning parameters for different domains and datasets. We present a clustering algorithm that achieves high accuracy across multiple domains and scales efficiently to high dimensions and large datasets. The presented algorithm optimizes a smooth continuous objective, which is based on robust statistics and allows heavily mixed clusters to be untangled. The continuous nature of the objective also allows clustering to be integrated as a module in end-to-end feature learning pipelines. We demonstrate this by extending the algorithm to perform joint clustering and dimensionality reduction by efficiently optimizing a continuous global objective. The presented approach is evaluated on large datasets of faces, hand-written digits, objects, newswire articles, sensor readings from the Space Shuttle, and protein expression levels. Our method achieves high accuracy across all datasets, outperforming the best prior algorithm by a factor of 3 in average rank.

  4. Reading in a Digital Age

    Science.gov (United States)

    Baron, Naomi S.

    2017-01-01

    The many advantages of reading digitally also bring with them implications for how we learn differently when we read differently. The author suggests that new contemporary technologies are changing the very notion of what it means to read. Even millennials acknowledge that their attention is more focused when they read print rather than online.…

  5. Early Reading and Concrete Operations.

    Science.gov (United States)

    Polk, Cindy L. Howes; Goldstein, David

    1980-01-01

    Indicated that early readers are more likely to be advanced in cognitive development than are nonearly-reading peers. After one year of formal reading instruction, early readers maintained their advantage in reading achievement. Measures of concrete operations were found to predict reading achievement for early and nonearly readers. (Author/DB)

  6. Prediction Methods for Blood Glucose Concentration

    DEFF Research Database (Denmark)

    “Recent Results on Glucose–Insulin Predictions by Means of a State Observer for Time-Delay Systems” by Pasquale Palumbo et al. introduces a prediction model which in real time predicts the insulin concentration in blood which in turn is used in a control system. The method is tested in simulation...... EEG signals to predict upcoming hypoglycemic situations in real-time by employing artificial neural networks. The results of a 30-day long clinical study with the implanted device and the developed algorithm are presented. The chapter “Meta-Learning Based Blood Glucose Predictor for Diabetic......, but the insulin amount is chosen using factors that account for this expectation. The increasing availability of more accurate continuous blood glucose measurement (CGM) systems is attracting much interest to the possibilities of explicit prediction of future BG values. Against this background, in 2014 a two...

  7. Glucose repression in Saccharomyces cerevisiae.

    Science.gov (United States)

    Kayikci, Ömur; Nielsen, Jens

    2015-09-01

    Glucose is the primary source of energy for the budding yeast Saccharomyces cerevisiae. Although yeast cells can utilize a wide range of carbon sources, presence of glucose suppresses molecular activities involved in the use of alternate carbon sources as well as it represses respiration and gluconeogenesis. This dominant effect of glucose on yeast carbon metabolism is coordinated by several signaling and metabolic interactions that mainly regulate transcriptional activity but are also effective at post-transcriptional and post-translational levels. This review describes effects of glucose repression on yeast carbon metabolism with a focus on roles of the Snf3/Rgt2 glucose-sensing pathway and Snf1 signal transduction in establishment and relief of glucose repression. © FEMS 2015.

  8. Closed-loop controlled noninvasive ultrasonic glucose sensing and insulin delivery

    Science.gov (United States)

    Park, Eun-Joo; Werner, Jacob; Jaiswal, Devina; Smith, Nadine Barrie

    2010-03-01

    To prevent complications in diabetes, the proper management of blood glucose levels is essential. Previously, ultrasonic transdermal methods using a light-weight cymbal transducer array has been studied for noninvasive methods of insulin delivery for Type-1 diabetes and glucose level monitoring. In this study, the ultrasound systems of insulin delivery and glucose sensing have been combined by a feedback controller. This study was designed to show the feasibility of the feedback controlled ultrasound system for the noninvasive glucose control. For perspective human application, in vivo experiments were performed on large animals that have a similar size to humans. Four in vivo experiments were performed using about 200 lbs pigs. The cymbal array of 3×3 pattern has been used for insulin delivery at 30 kHz with the spatial-peak temporal-peak intensity (Isptp) of 100 mW/cm2. For glucose sensing, a 2×2 array was operated at 20 kHz with Isptp = 100 mW/cm2. Based on the glucose level determined by biosensors after the ultrasound exposure, the ultrasound system for the insulin delivery was automatically operated. The glucose level of 115 mg/dl was set as a reference value for operating the insulin delivery system. For comparison, the glucose levels of blood samples collected from the ear vein were measured by a commercial glucose meter. Using the ultrasound system operated by the close-loop, feed-back controller, the glucose levels of four pigs were determined every 20 minutes and continuously controlled for 120 minutes. In comparison to the commercial glucose meter, the glucose levels determined by the biosensor were slightly higher. The results of in vivo experiments indicate the feasibility of the feedback controlled ultrasound system using the cymbal array for noninvasive glucose sensing and insulin delivery. Further studies on the extension of the glucose control will be continued for the effective method of glucose control.

  9. Glucose metabolism in lactating reindeer

    Energy Technology Data Exchange (ETDEWEB)

    White, R G; Luick, J R

    1976-01-01

    Changes in glucose synthesis during the lactation cycle were estimated in pen-fed and grazing reindeer. The pool size, space, transfer rate, and irreversible loss of glucose were determined using simultaneous injections of (2-/sup 3/H)glucose and primed infusions of (U-/sup 14/C)glucose in reindeer lactating for 1-2, 4-5, 8-9, and 12-16 weeks. Glucose transfer rate and irreversible loss were higher during early to midlactation than at other times of the year; maximum estimates were at 8-9 week postpartum (July), and a decline was noted at 12-16 weeks (August). During the first 1-2 weeks in pen-fed and 4-5 weeks in grazing reindeer, glucose transfer rate and irreversible loss were almost twice the values reported for reindeer at maintenance. No difference in the irreversible loss of glucose was noted between lactating and non-lactating reindeer at 18-20 weeks postpartum (September), and there is evidence that this may occur as early as 12-16 weeks postpartum. No significant trend was noted in the glucose space throughout lactation; however, a significant increase in plasma glucose concentration and pool size was noted when glucose synthesis was highest (8-9 weeks postpartum). Glucose turnover time was consistently faster (78-88 min) in lactating than in non-lactating reindeer (107-140 min). Reindeer used a smaller proportion of plasma glucose-C for lactose synthesis than did other domestic species. This probably results from the low lactose content of reindeer milk and the relatively low rate of milk secretion. (auth)

  10. The Impact of Past Language Arts Teachers on the Reading Motivation of Twelfth Grade Students

    Science.gov (United States)

    Shepard, Courtney A.

    2017-01-01

    Adolescents' motivation to read continues to decline. The purpose of this embedded single case study was to explore adolescent reading motivation to determine some ways in which adolescents are motivated to read. Through purposeful sampling, the participants included seven twelfth grade students and three English Language Arts teachers in grades…

  11. Teaching Reading and Spelling to Adult Learners: The Multisensory Structured Language Approach

    Science.gov (United States)

    Ali, Shamim

    2012-01-01

    All over the World most effective methods for teaching reading to beginning-level adults have been applied. My continuing challenge has been to determine how reading acquisition research can be applied to teaching reading to adults. In this article, I describe the techniques I have found most useful; I hope other teachers working with beginning…

  12. Monitoring Progress toward Independent Silent Reading.

    Science.gov (United States)

    Franc, Lillian H.; Hildebrandt, Jeannette

    1984-01-01

    Concludes, among other things, that fluent oral reading is an important step toward reading for meaning and independent silent reading and that silent reading should be encouraged from the beginning of reading instruction. (FL)

  13. Glucose repression in Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Kayikci, Omur; Nielsen, Jens

    2015-01-01

    Glucose is the primary source of energy for the budding yeast Saccharomyces cerevisiae. Although yeast cells can utilize a wide range of carbon sources, presence of glucose suppresses molecular activities involved in the use of alternate carbon sources as well as it represses respiration and gluc......Glucose is the primary source of energy for the budding yeast Saccharomyces cerevisiae. Although yeast cells can utilize a wide range of carbon sources, presence of glucose suppresses molecular activities involved in the use of alternate carbon sources as well as it represses respiration...

  14. Recent Advances in Fluorescent Arylboronic Acids for Glucose Sensing

    Directory of Open Access Journals (Sweden)

    Jon Stefan Hansen

    2013-12-01

    Full Text Available Continuous glucose monitoring (CGM is crucial in order to avoid complications caused by change in blood glucose for patients suffering from diabetes mellitus. The long-term consequences of high blood glucose levels include damage to the heart, eyes, kidneys, nerves and other organs, among others, caused by malign glycation of vital protein structures. Fluorescent monitors based on arylboronic acids are promising candidates for optical CGM, since arylboronic acids are capable of forming arylboronate esters with 1,2-cis-diols or 1,3-diols fast and reversibly, even in aqueous solution. These properties enable arylboronic acid dyes to provide immediate information of glucose concentrations. Thus, the replacement of the commonly applied semi-invasive and non-invasive techniques relying on glucose binding proteins, such as concanavalin A, or enzymes, such as glucose oxidase, glucose dehydrogenase and hexokinases/glucokinases, might be possible. The recent progress in the development of fluorescent arylboronic acid dyes will be emphasized in this review.

  15. Alterations in glucose kinetics induced by pentobarbital anesthesia

    International Nuclear Information System (INIS)

    Lang, C.H.; Bagby, G.J.; Hargrove, D.M.; Hyde, P.M.; Spitzer, J.J.

    1987-01-01

    Because pentobarbital is often used in investigations related to carbohydrate metabolism, the in vivo effect of this drug on glucose homeostasis was studied. Glucose kinetics assessed by the constant intravenous infusion of [6- 3 H]- and [U- 14 C]glucose, were determined in three groups of catheterized fasted rats: conscious, anesthetized and body temperature maintained, and anesthetized but body temperature not maintained. After induction of anesthesia, marked hypothermia developed in rats not provided with external heat. Anesthetized rats that developed hypothermia showed a decrease in mean arterial blood pressure (25%) and heart rate (40%). Likewise, the plasma lactate concentration and the rates of glucose appearance, recycling, and metabolic clearance were reduced by 30-50% in the hypothermic anesthetized rats. Changes in whole-body carbohydrate metabolism were prevented when body temperature was maintained. Because plasma pentobarbital levels were similar between the euthermic and hypothermic rats during the first 2 h of the experiment, the rapid reduction in glucose metabolism in this latter group appears related to the decrease in body temperature. The continuous infusion of epinephrine produced alterations in glucose kinetics that were not different between conscious animals and anesthetized rats with body temperature maintained. Thus pentobarbital-anesthetized rats became hypothermic when kept at room temperature and exhibited marked decreases in glucose metabolism. Such changes were absent when body temperature was maintained during anesthesia

  16. Mathematical model of glucose-insulin homeostasis in healthy rats.

    Science.gov (United States)

    Lombarte, Mercedes; Lupo, Maela; Campetelli, German; Basualdo, Marta; Rigalli, Alfredo

    2013-10-01

    According to the World Health Organization there are over 220 million people in the world with diabetes and 3.4 million people died in 2004 as a consequence of this pathology. Development of an artificial pancreas would allow to restore control of blood glucose by coupling an infusion pump to a continuous glucose sensor in the blood. The design of such a device requires the development and application of mathematical models which represent the gluco-regulatory system. Models developed by other research groups describe very well the gluco-regulatory system but have a large number of mathematical equations and require complex methodologies for the estimation of its parameters. In this work we propose a mathematical model to study the homeostasis of glucose and insulin in healthy rats. The proposed model consists of three differential equations and 8 parameters that describe the variation of: blood glucose concentration, blood insulin concentration and amount of glucose in the intestine. All parameters were obtained by setting functions to the values of glucose and insulin in blood obtained after oral glucose administration. In vivo and in silico validations were performed. Additionally, a qualitative analysis has been done to verify the aforementioned model. We have shown that this model has a single, biologically consistent equilibrium point. This model is a first step in the development of a mathematical model for the type I diabetic rat. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Reading through Films

    Directory of Open Access Journals (Sweden)

    Madhavi Gayathri Raman

    2016-02-01

    Full Text Available This paper captures the design of a comprehensive curriculum incorporating the four skills based exclusively on the use of parallel audio-visual and written texts. We discuss the use of authentic materials to teach English to Indian undergraduates aged 18 to 20 years. Specifically, we talk about the use of parallel reading (screen-play and audio-visual texts (Shawshank Redemption, and Life is Beautiful, A Few Good Men and Lion King drawn from popular culture in the classroom as an effective teaching medium. Students were gradually introduced to films based on novels with extracts from the original texts (Schindler’s List, Beautiful Mind for extended reading and writing practice. We found that students began to pay more attention to aspects such as pronunciation, intonational variations, discourse markers and vocabulary items (phrasal verbs, synonyms, homophones, and puns. Keywords: Reading, films, popular culture, ESL classroom, language skills

  18. [Binocular coordination during reading].

    Science.gov (United States)

    Bassou, L; Granié, M; Pugh, A K; Morucci, J P

    1992-01-01

    Is there an effect on binocular coordination during reading of oculomotor imbalance (heterophoria, strabismus and inadequate convergence) and of functional lateral characteristics (eye preference and perceptually privileged visual laterality)? Recordings of the binocular eye-movements of ten-year-old children show that oculomotor imbalances occur most often among children whose left visual perceptual channel is privileged, and that these subjects can present optomotor dissociation and manifest lack of motor coordination. Close binocular motor coordination is far from being the norm in reading. The faster reader displays saccades of differing spatial amplitude and the slower reader an oculomotor hyperactivity, especially during fixations. The recording of binocular movements in reading appears to be an excellent means of diagnosing difficulties related to visual laterality and to problems associated with oculomotor imbalance.

  19. The Explicit Instruction of Reading Strategies: Directed Reading Thinking Activity vs. Guided Reading Strategies

    Directory of Open Access Journals (Sweden)

    Mohammad Mehdi Yazdani

    2015-05-01

    Full Text Available Investigating the efficiencies and deficiencies of reading strategies is one of the noticeable issues in the related theory and research in reading comprehension instruction. This study was to examine the impact of Directed Reading Thinking Activity (DRTA and Guided Reading (GR on reading comprehension. Sixty three Iranian students of grade one in Shahed high school in the city of Bojnourd took part in the study. They were assigned in three groups, one control and two experimental groups. The instruction lasted for ten weeks. This study utilized a pretest posttest control group in quantitative quasi- experimental design. The same reading comprehension test was administered as pre-test and post-test. The results were twofold: First, the instruction of learning strategies could foster reading comprehension skill. Second, while the explicit instruction of both strategies could improve the students' reading comprehension skill, Directed Reading Thinking Activity had a more significant positive effect than Guided Reading.

  20. READING STATISTICS AND RESEARCH

    Directory of Open Access Journals (Sweden)

    Reviewed by Yavuz Akbulut

    2008-10-01

    Full Text Available The book demonstrates the best and most conservative ways to decipher and critique research reports particularly for social science researchers. In addition, new editions of the book are always better organized, effectively structured and meticulously updated in line with the developments in the field of research statistics. Even the most trivial issues are revisited and updated in new editions. For instance, purchaser of the previous editions might check the interpretation of skewness and kurtosis indices in the third edition (p. 34 and in the fifth edition (p.29 to see how the author revisits every single detail. Theory and practice always go hand in hand in all editions of the book. Re-reading previous editions (e.g. third edition before reading the fifth edition gives the impression that the author never stops ameliorating his instructional text writing methods. In brief, “Reading Statistics and Research” is among the best sources showing research consumers how to understand and critically assess the statistical information and research results contained in technical research reports. In this respect, the review written by Mirko Savić in Panoeconomicus (2008, 2, pp. 249-252 will help the readers to get a more detailed overview of each chapters. I cordially urge the beginning researchers to pick a highlighter to conduct a detailed reading with the book. A thorough reading of the source will make the researchers quite selective in appreciating the harmony between the data analysis, results and discussion sections of typical journal articles. If interested, beginning researchers might begin with this book to grasp the basics of research statistics, and prop up their critical research reading skills with some statistics package applications through the help of Dr. Andy Field’s book, Discovering Statistics using SPSS (second edition published by Sage in 2005.

  1. Reading Authentic Texts

    DEFF Research Database (Denmark)

    Balling, Laura Winther

    2013-01-01

    Most research on cognates has focused on words presented in isolation that are easily defined as cognate between L1 and L2. In contrast, this study investigates what counts as cognate in authentic texts and how such cognates are read. Participants with L1 Danish read news articles in their highly...... proficient L2, English, while their eye-movements were monitored. The experiment shows a cognate advantage for morphologically simple words, but only when cognateness is defined relative to translation equivalents that are appropriate in the context. For morphologically complex words, a cognate disadvantage...... word predictability indexed by the conditional probability of each word....

  2. Effect of i.v. dextrose administration on glucose metabolism during surgery.

    Science.gov (United States)

    Schricker, Thomas; Lattermann, Ralph; Wykes, Linda; Carli, Franco

    2004-01-01

    The inhibitory influence of exogenous dextrose on glucose production has been shown to be less pronounced during injury and sepsis. This protocol was designed to investigate the effect of i.v. hypocaloric dextrose on glucose metabolism during elective abdominal surgery. Fourteen patients with rectal cancer were studied under fasting conditions and toward the end of a 3-hour infusion of dextrose (2 mg.kg-1 per minute) either in absence (control group, n = 7) or presence of colonic surgery (surgery group, n = 7). Endogenous glucose production was determined by using primed continuous infusions of [6,6-2H2]glucose before and during dextrose administration. We also measured the plasma concentrations of glucose, lactate, cortisol, glucagon, and insulin. The administration of dextrose decreased the endogenous glucose production in all patients (p dextrose infusion in both groups (p Dextrose infusion increased the plasma insulin concentrations to the same extent in both groups (p dextrose on endogenous glucose production.

  3. Prediction of Glucose Tolerance without an Oral Glucose Tolerance Test

    Directory of Open Access Journals (Sweden)

    Rohit Babbar

    2018-03-01

    Full Text Available IntroductionImpaired glucose tolerance (IGT is diagnosed by a standardized oral glucose tolerance test (OGTT. However, the OGTT is laborious, and when not performed, glucose tolerance cannot be determined from fasting samples retrospectively. We tested if glucose tolerance status is reasonably predictable from a combination of demographic, anthropometric, and laboratory data assessed at one time point in a fasting state.MethodsGiven a set of 22 variables selected upon clinical feasibility such as sex, age, height, weight, waist circumference, blood pressure, fasting glucose, HbA1c, hemoglobin, mean corpuscular volume, serum potassium, fasting levels of insulin, C-peptide, triglyceride, non-esterified fatty acids (NEFA, proinsulin, prolactin, cholesterol, low-density lipoprotein, HDL, uric acid, liver transaminases, and ferritin, we used supervised machine learning to estimate glucose tolerance status in 2,337 participants of the TUEF study who were recruited before 2012. We tested the performance of 10 different machine learning classifiers on data from 929 participants in the test set who were recruited after 2012. In addition, reproducibility of IGT was analyzed in 78 participants who had 2 repeated OGTTs within 1 year.ResultsThe most accurate prediction of IGT was reached with the recursive partitioning method (accuracy = 0.78. For all classifiers, mean accuracy was 0.73 ± 0.04. The most important model variable was fasting glucose in all models. Using mean variable importance across all models, fasting glucose was followed by NEFA, triglycerides, HbA1c, and C-peptide. The accuracy of predicting IGT from a previous OGTT was 0.77.ConclusionMachine learning methods yield moderate accuracy in predicting glucose tolerance from a wide set of clinical and laboratory variables. A substitution of OGTT does not currently seem to be feasible. An important constraint could be the limited reproducibility of glucose tolerance status during a

  4. Simulation and qualitative analysis of glucose variability, mean glucose, and hypoglycemia after subcutaneous insulin therapy for stress hyperglycemia.

    Science.gov (United States)

    Strilka, Richard J; Stull, Mamie C; Clemens, Michael S; McCaver, Stewart C; Armen, Scott B

    2016-01-27

    The critically ill can have persistent dysglycemia during the "subacute" recovery phase of their illness because of altered gene expression; it is also not uncommon for these patients to receive continuous enteral nutrition during this time. The optimal short-acting subcutaneous insulin therapy that should be used in this clinical scenario, however, is unknown. Our aim was to conduct a qualitative numerical study of the glucose-insulin dynamics within this patient population to answer the above question. This analysis may help clinicians design a relevant clinical trial. Eight virtual patients with stress hyperglycemia were simulated by means of a mathematical model. Each virtual patient had a different combination of insulin resistance and insulin deficiency that defined their unique stress hyperglycemia state; the rate of gluconeogenesis was also doubled. The patients received 25 injections of subcutaneous regular or Lispro insulin (0-6 U) with 3 rates of continuous nutrition. The main outcome measurements were the change in mean glucose concentration, the change in glucose variability, and hypoglycemic episodes. These end points were interpreted by how the ultradian oscillations of glucose concentration were affected by each insulin preparation. Subcutaneous regular insulin lowered both mean glucose concentrations and glucose variability in a linear fashion. No hypoglycemic episodes were noted. Although subcutaneous Lispro insulin lowered mean glucose concentrations, glucose variability increased in a nonlinear fashion. In patients with high insulin resistance and nutrition at goal, "rebound hyperglycemia" was noted after the insulin analog was rapidly metabolized. When the nutritional source was removed, hypoglycemia tended to occur at higher Lispro insulin doses. Finally, patients with severe insulin resistance seemed the most sensitive to insulin concentration changes. Subcutaneous regular insulin consistently lowered mean glucose concentrations and glucose

  5. Increased glucose dependence in resting, iron-deficient rats

    International Nuclear Information System (INIS)

    Brooks, G.A.; Henderson, S.A.; Dallman, P.R.

    1987-01-01

    Rates of blood glucose and lactate turnover were assessed in resting iron-deficient and iron-sufficient (control) rats to test the hypothesis that dependence on glucose metabolism is increased in iron deficiency. Male Sprague-Dawley rats, 21 days old, were fed a diet containing either 6 mg iron/kg feed (iron-deficient group) or 50 mg iron/kg feed (iron-sufficient group) for 3-4 wk. The iron-deficient group became anemic, with hemoglobin levels of 6.4 ± 0.2 compared with 13.8 ± 0.3 g/dl for controls. Rats received a 90-min primed continuous infusion of D-[6- 3 H]glucose and sodium L-[U- 14 C]lactate via a jugular catheter. Serial samples were taken from a carotid catheter for concentration and specific activity determinations. Iron-deficient rats had significantly higher blood glucose and lactate concentrations than controls. The iron-deficient group had a significantly higher glucose turnover rate than the control group. Significantly more metabolite recycling in iron-deficient rats was indicated by greater incorporation of 14 C into blood glucose. Assuming a carbon crossover correction factor of 2, half of blood glucose arose from lactate in deficient animals. By comparison, only 25% of glucose arose from lactate in controls. Lack of a difference in lactate turnover rates between deficient rats and controls was attributed to 14 C recycling. The results indicate a greater dependence on glucose metabolism in iron-deficient rats

  6. Computer Simulation of Reading.

    Science.gov (United States)

    Leton, Donald A.

    In recent years, coding and decoding have been claimed to be the processes for converting one language form to another. But there has been little effort to locate these processes in the human learner or to identify the nature of the internal codes. Computer simulation of reading is useful because the similarities in the human reception and…

  7. Readings in risk

    National Research Council Canada - National Science Library

    Glickman, Theodore S; Gough, Michael

    1990-01-01

    ... from Resources for the Future are distributed worldwide by The Johns Hopkins University Press. Library of Congress Cataloging-in-Publication Data Readings in risk I Theodore S. Glickman and Michael Gough, editors. p. cm. Includes bibliographical references. ISBN 0-915707-55-1 (alk. paper) 1. Technology-Risk assessment. 2. Health risk assessment....

  8. Time for Reading

    Science.gov (United States)

    Waters, Lindsay

    2007-01-01

    Over the last 50 years, certain ideas have become dominant that make learning to read different than it once was than the ideas that children are neurologically "wired" to use language "competently" in certain ways. Noam Chomsky has promoted the idea that there are certain "syntactic structures" hard-wired in the human brain. That view, the author…

  9. Recipe for Reading.

    Science.gov (United States)

    Jenkins, Jacquelyn W.; Shaul, Nancy Pera

    The program described in this paper was based upon the premise that the activity of cooking in the classroom is an excellent way of integrating all areas of learning and a very useful reading vehicle. Through cooking activities and related field trips, children can add to both their knowledge in basic subject areas and their motor skills as well…

  10. Painless reading comprehension

    CERN Document Server

    Jones, EdD, Darolyn "Lyn"

    2016-01-01

    Reading comprehension gets easier as students learn what kind of reader they are, discover how to keep facts in their head, and much more. Bonus Online Component: includes additional games, including Beat the Clock, a line match game, and a word scramble.

  11. Reading, Perception and Language.

    Science.gov (United States)

    Duane, Drake D., Ed.; Rawson, Margaret B., Ed.

    The nine papers in this book discuss aspects of language processing that contribute to reading difficulty. After a summary of the 1974 World Congress on Dyslexia, at which these papers were presented, the following subjects are examined: historical background and educational treatment of dyslexia; the structure of language; neuroanatomy underlying…

  12. Books for Summer Reading.

    Science.gov (United States)

    Phi Delta Kappan, 1992

    1992-01-01

    Advises administrators to use their summers to relax and recharge their intellectual batteries. Reading suggestions include Edith Wharton's "House of Mirth," Charlotte Perkins Gilman's "The Yellow Wallpaper," Amy Tan's "Joy Luck Club," China Achebe's "Things Fall Apart," Paule Marshall's "The Chosen…

  13. Reading in Place

    Science.gov (United States)

    Price, Leah

    2012-01-01

    The digital age is rendering books more common, not less. It is true that there is nothing new about "furniture books": The trade in reading material has long been dwarfed by the market for coffee-table books, books that steakhouse chains buy by the yard, empty bindings that interior decorators use to accessorize the upholstery. As coffee-table…

  14. Reading's Next Chapter

    Science.gov (United States)

    Kellman, Steven G.

    2008-01-01

    It is hard to imagine a world without books. Reading represents a mode of thinking and being that may be overshadowed in a contemporary world of web sites, movies, TV shows, CDs and video games. Ultimately, the author concludes that the percentage of serious readers has probably not changed significantly during the past century: what has changed…

  15. Engineering of Class II Cellobiose Dehydrogenases for Improved Glucose Sensitivity and Reduced Maltose Affinity

    DEFF Research Database (Denmark)

    Ortiz, Roberto; Rahman, Mahbubur; Zangrilli, Beatrice

    2017-01-01

    The front cover artwork is provided by Prof. Lo Gorton from Lund University (Sweden) and his co-workers. The image shows mutated cellobiose dehydrogenase (CDH) immobilized on a graphite electrode and how preferentially glucose is oxidized by this enzyme. Read the full text of the Article at 10.1002...

  16. SchemaOnRead Manual

    Energy Technology Data Exchange (ETDEWEB)

    North, Michael J. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2015-09-30

    SchemaOnRead provides tools for implementing schema-on-read including a single function call (e.g., schemaOnRead("filename")) that reads text (TXT), comma separated value (CSV), raster image (BMP, PNG, GIF, TIFF, and JPG), R data (RDS), HDF5, NetCDF, spreadsheet (XLS, XLSX, ODS, and DIF), Weka Attribute-Relation File Format (ARFF), Epi Info (REC), Pajek network (PAJ), R network (NET), Hypertext Markup Language (HTML), SPSS (SAV), Systat (SYS), and Stata (DTA) files. It also recursively reads folders (e.g., schemaOnRead("folder")), returning a nested list of the contained elements.

  17. Parents' reading-related knowledge and children's reading acquisition.

    Science.gov (United States)

    Ladd, Megan; Martin-Chang, Sandra; Levesque, Kyle

    2011-12-01

    Teacher reading-related knowledge (phonological awareness and phonics knowledge) predicts student reading, however little is known about the reading-related knowledge of parents. Participants comprised 70 dyads (children from kindergarten and grade 1 and their parents). Parents were administered a questionnaire tapping into reading-related knowledge, print exposure, storybook reading, and general cultural knowledge. Children were tested on measures of letter-word knowledge, sound awareness, receptive vocabulary, oral expression, and mathematical skill. Parent reading-related knowledge showed significant positive links with child letter-word knowledge and sound awareness, but showed no correlations with child measures of mathematical skill or vocabulary. Furthermore, parent reading-related knowledge was not associated with parents' own print exposure or cultural knowledge, indicating that knowledge about English word structure may be separate from other cognitive skills. Implications are discussed in terms of improving parent reading-related knowledge to promote child literacy.

  18. Glucose uptake and pulsatile insulin infusion: euglycaemic clamp and [3-3H]glucose studies in healthy subjects

    International Nuclear Information System (INIS)

    Schmitz, O.; Arnfred, J.; Hother Nielsen, O.; Beck-Nielsen, H.; Oerskov, H.

    1986-01-01

    To test the hypothesis that insulin has a greater effect on glucose metabolism when given as pulsatile than as continuous infusion, a 354-min euglycaemic clamp study was carried out in 8 healthy subjects. At random order soluble insulin was given intravenously either at a constant rate of 0.45mU/kg · min or in identical amounts in pulses of 1 1 / 2 to 2 1 / 4 min followed by intervals of 10 1 / 2 to 9 3 / 4 min. Average serum insulin levels were similar during the two infusion protocols, but pulsatile administration induced oscillations ranging between 15 and 62 μU/ml. Glucose uptake expressed as metabolic clearance rate (MCR) for glucose was significantly increased during pulsatile insulin delivery as compared with continuous administration (270-294 min: 8.7±0.7 vs 6.8±0.9 ml/kg · min, P 3 H]glucose infusion technique was suppressed to insignificant values. Finally, the effect of insulin on endogenous insulin secretion and lipolysis as assessed by changes in serum C-peptide and serum FFA was uninfluenced by the infusion mode. In conclusion, insulin infusion resulting in physiological serum insulin levels enhances glucose uptake in peripheral tissues in healthy subjects to a higher degree when given in a pulsed pattern mimicking that of the normal endocrine pancreas than when given as a continuous infusion. (author)

  19. Exogenous glucagon-like peptide-1 attenuates glucose absorption and reduces blood glucose concentration after small intestinal glucose delivery in critical illness.

    Science.gov (United States)

    Miller, Asaf; Deane, Adam M; Plummer, Mark P; Cousins, Caroline E; Chapple, Lee-Anne S; Horowitz, Michael; Chapman, Marianne J

    2017-03-01

    To evaluate the effect of exogenous glucagonlike peptide-1 (GLP-1) on small intestinal glucose absorption and blood glucose concentrations during critical illness. A prospective, blinded, placebo-controlled, cross-over, randomised trial in a mixed medical-surgical adult intensive care unit, with 12 mechanically ventilated critically ill patients, who were suitable for receiving small intestinal nutrient. On consecutive days, in a randomised order, participants received intravenous GLP-1 (1.2 pmol/ kg/min) or placebo (0.9% saline) as a continuous infusion over 270 minutes. After 6 hours of fasting, intravenous infusions of GLP-1 or placebo began at T = -30 min (in which T = time), with the infusion maintained at a constant rate until study completion at T = 240 min. At T = 0 min, a 100 mL bolus of mixed liquid nutrient meal (1 kcal/mL) containing 3 g of 3-O-methyl-D-gluco-pyranose (3-OMG), a marker of glucose absorption, was administered directly into the small intestine, via a post-pyloric catheter, over 6 minutes. Blood samples were taken at regular intervals for the measurement of plasma glucose and 3-OMG concentrations. Intravenous GLP-1 attenuated initial small intestinal glucose absorption (mean area under the curve [AUC] 0-30 for 3-OMG: GLP-1 group, 4.4 mmol/L/min [SEM, 0.9 mmol/L/min] v placebo group, 6.5 mmol/L/min [SEM, 1.0 mmol/L/min]; P = 0.01), overall small intestinal glucose absorption (mean AUC 0-240 for 3-OMG: GLP-1, 68.2 mmol/L/ min [SEM, 4.7 mmol/L/min] v placebo, 77.7 mmol/L/min [SEM, 4.4 mmol/lLmin]; P = 0.02), small intestinal glucose absorption and overall blood glucose concentration (mean AUC 0-240 for blood glucose: GLP-1, 2062 mmol/L/min [SEM, 111 mmol/L/min] v placebo 2328 mmol/L/min [SEM, 145 mmol/L/min]; P = 0.005). Short-term administration of exogenous GLP-1 reduces small intestinal glucose absorption for up to 4 hours during critical illness. This is likely to be an additional mechanism for the glucose-lowering effect of this agent.

  20. Teachers’ beliefs about reading and use of reading strategies

    OpenAIRE

    VASILIKA RRAKU

    2014-01-01

    The aim of this article is to place the focus on teachers’ beliefs about reading and reading strategies to the purpose of emphasizing the im portance of reading strategies in the reading process. The method of study is analytic analysis of teachers’ beliefs obtained through ques tionnaires delivered to 18 English language teachers of elementary, secondary and high level education in the region of Saranda in lbania. The results of the study pointed to a great concordance between teach ers’ bel...