WorldWideScience

Sample records for contamination tonapah test

  1. Test installation for separation of contaminated/activated concrete

    International Nuclear Information System (INIS)

    Klok, H.; Peeze Binkhorst, I.A.G.M.

    1993-01-01

    Large amounts of contaminated concrete are released when dismantling nuclear power plants. Volume reduction of contaminated concrete has economic and environmental advantages. A test facility has been built by which contaminated concrete can be separated in clean aggregate and contaminated cement. During the tests a considerable amount of dust accumulated in the valve construction of the test installation. This could result in an unacceptable accumulation of contaminated dust, blocking of the handle and emission of dust and grit during the operation of the test facility. The design of the valve construction was adjusted by using and testing flexible materials

  2. Comparing statistical tests for detecting soil contamination greater than background

    International Nuclear Information System (INIS)

    Hardin, J.W.; Gilbert, R.O.

    1993-12-01

    The Washington State Department of Ecology (WSDE) recently issued a report that provides guidance on statistical issues regarding investigation and cleanup of soil and groundwater contamination under the Model Toxics Control Act Cleanup Regulation. Included in the report are procedures for determining a background-based cleanup standard and for conducting a 3-step statistical test procedure to decide if a site is contaminated greater than the background standard. The guidance specifies that the State test should only be used if the background and site data are lognormally distributed. The guidance in WSDE allows for using alternative tests on a site-specific basis if prior approval is obtained from WSDE. This report presents the results of a Monte Carlo computer simulation study conducted to evaluate the performance of the State test and several alternative tests for various contamination scenarios (background and site data distributions). The primary test performance criteria are (1) the probability the test will indicate that a contaminated site is indeed contaminated, and (2) the probability that the test will indicate an uncontaminated site is contaminated. The simulation study was conducted assuming the background concentrations were from lognormal or Weibull distributions. The site data were drawn from distributions selected to represent various contamination scenarios. The statistical tests studied are the State test, t test, Satterthwaite's t test, five distribution-free tests, and several tandem tests (wherein two or more tests are conducted using the same data set)

  3. Bioavailability assessment of contaminants in soils via respiration and nitrification tests

    International Nuclear Information System (INIS)

    Hund-Rinke, Kerstin; Simon, Markus

    2008-01-01

    For the assessment of contaminated soils ecotoxicological tests are used to estimate the bioavailability of contaminants in soil samples. Terrestrial tests reveal the habitat function of soils, and parameters applied in tests involving microorganisms include respiration activity and potential ammonium oxidation. For such tests, the threshold values needed to assess the results have already been established in guidelines ISO 17155 and ISO 15685. In this paper, we discuss about the respiration activity and potential ammonium oxidation results obtained from a wide variety of soils with different physico-chemical properties and levels of contamination. These results show that microbial respiration and potential ammonium oxidation have different sensitivities to various classes of contaminants. We demonstrated that both organic and inorganic contaminants influence potential ammonium oxidation, whereas microbial respiration is predominantly affected by biodegradable organic contaminants. These differences might be useful for more detailed assessments of soil contamination, leading to different recommended actions depending on which parameter is affected. - The paper provides a further criterion for a more detailed assessment of soil contamination, leading to different recommended actions depending on which parameter is affected

  4. Bioavailability assessment of contaminants in soils via respiration and nitrification tests

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, Kerstin [Fraunhofer Institute for Molecular Biology and Applied Ecology, Auf dem Aberg 1, 57392 Schmallenberg (Germany)], E-mail: kerstin.hund-rinke@ime.fraunhofer.de; Simon, Markus [Fraunhofer Institute for Molecular Biology and Applied Ecology, Auf dem Aberg 1, 57392 Schmallenberg (Germany)], E-mail: markus.simon@ime.fraunhofer.de

    2008-05-15

    For the assessment of contaminated soils ecotoxicological tests are used to estimate the bioavailability of contaminants in soil samples. Terrestrial tests reveal the habitat function of soils, and parameters applied in tests involving microorganisms include respiration activity and potential ammonium oxidation. For such tests, the threshold values needed to assess the results have already been established in guidelines ISO 17155 and ISO 15685. In this paper, we discuss about the respiration activity and potential ammonium oxidation results obtained from a wide variety of soils with different physico-chemical properties and levels of contamination. These results show that microbial respiration and potential ammonium oxidation have different sensitivities to various classes of contaminants. We demonstrated that both organic and inorganic contaminants influence potential ammonium oxidation, whereas microbial respiration is predominantly affected by biodegradable organic contaminants. These differences might be useful for more detailed assessments of soil contamination, leading to different recommended actions depending on which parameter is affected. - The paper provides a further criterion for a more detailed assessment of soil contamination, leading to different recommended actions depending on which parameter is affected.

  5. Contaminant Boundary at the Faultless Underground Nuclear Test

    International Nuclear Information System (INIS)

    Greg Pohll; Karl Pohlmann; Jeff Daniels; Ahmed Hassan; Jenny Chapman

    2003-01-01

    The U.S. Department of Energy (DOE) and the Nevada Division of Environmental Protection (NDEP) have reached agreement on a corrective action strategy applicable to address the extent and potential impact of radionuclide contamination of groundwater at underground nuclear test locations. This strategy is described in detail in the Federal Facility Agreement and Consent Order (FFACO, 2000). As part of the corrective action strategy, the nuclear detonations that occurred underground were identified as geographically distinct corrective action units (CAUs). The strategic objective for each CAU is to estimate over a 1,000-yr time period, with uncertainty quantified, the three-dimensional extent of groundwater contamination that would be considered unsafe for domestic and municipal use. Two types of boundaries (contaminant and compliance) are discussed in the FFACO that will map the three-dimensional extent of radionuclide contamination. The contaminant boundary will identify the region wi th 95 percent certainty that contaminants do not exist above a threshold value. It will be prepared by the DOE and presented to NDEP. The compliance boundary will be produced as a result of negotiation between the DOE and NDEP, and can be coincident with, or differ from, the contaminant boundary. Two different thresholds are considered for the contaminant boundary. One is based on the enforceable National Primary Drinking Water Regulations for radionuclides, which were developed as a requirement of the Safe Drinking Water Act. The other is a risk-based threshold considering applicable lifetime excess cancer-risk-based criteria The contaminant boundary for the Faultless underground nuclear test at the Central Nevada Test Area (CNTA) is calculated using a newly developed groundwater flow and radionuclide transport model that incorporates aspects of both the original three-dimensional model (Pohlmann et al., 1999) and the two-dimensional model developed for the Faultless data decision

  6. Firm contracts for treatability tests on contaminated soils

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    Geosafe Corporation, a Pacific Northwest-headquartered hazardous waste remediation company, announced that is has successfully completed treatability testing of contaminated soils under contract with Woodward Clyde Consultants of Denver, Colorado, the prime contractor for a major hazardous waste site in the Western United States. The tests are being conducted at the University of Washington with Geosafe's specially-designed test equipment. The recently concluded testing confirms the ability of Geosafe's patented in situ vitrification (ISV) technology to treat soils containing a variety of organic and inorganic contaminants. ISV, for which Geosafe has worldwide rights, is the only technology available today that will fully comply with the Superfund Amendments and Reauthorization Act. The ability of ISV to treat mixtures of organic, inorganic and radioactive wastes in situ, in a single process, offers distinct advantages over excavation, transportation and incineration. During the ISV process, organic contaminants are pyrolized and the inorganics present are chemically incorporated into the molten soil which, when cooled, resembles naturally-occurring obsidian

  7. Study of radionuclide contamination at the former Semipalatinsk test site

    International Nuclear Information System (INIS)

    Artemyev, O.A.

    2002-01-01

    In the paper the contamination technical areas of the former Semipalatinsk test site is discussed in details. It is concluded, that radioactive contamination of the Degelen technical area caused by underground nuclear tests is mainly retained within tunnels and cavities. Investigation showed that many tunnel portal areas here are contaminated by radioactive substances. Areas of significantly high contamination levels are also found at the Balapan technical area mainly around borehole sleeves. A serious source of radioactive contamination is tritium in used boreholes and high content of radionuclides produced due to the fission of nuclear device and activation of rocks at crater rim around the Atom lake

  8. Helium leak testing of a radioactive contaminated vessel under high pressure in a contaminated environment

    International Nuclear Information System (INIS)

    Winter, M.E.

    1996-01-01

    At ANL-W, with the shutdown of EBR-II, R ampersand D has evolved from advanced reactor design to the safe handling, processing, packaging, and transporting spent nuclear fuel and nuclear waste. New methods of processing spent fuel rods and transforming contaminated material into acceptable waste forms are now in development. Storage of nuclear waste is a high interest item. ANL-W is participating in research of safe storage of nuclear waste, with the WIPP (Waste Isolation Pilot Plant) site in New Mexico the repository. The vessel under test simulates gas generated by contaminated materials stored underground at the WIPP site. The test vessel is 90% filled with a mixture of contaminated material and salt brine (from WIPP site) and pressurized with N2-1% He at 2500 psia. Test acceptance criteria is leakage -7 cc/seconds at 2500 psia. The bell jar method is used to determine leakage rate using a mass spectrometer leak detector (MSLD). The efficient MSLD and an Al bell jar replaced a costly, time consuming pressure decay test setup. Misinterpretation of test criterion data caused lengthy delays, resulting in the development of a unique procedure. Reevaluation of the initial intent of the test criteria resulted in leak tolerances being corrected and test efficiency improved

  9. Test and evaluation of radioactively contaminated transducers and transmitters

    International Nuclear Information System (INIS)

    Strahm, R.C.

    1983-01-01

    People in the nuclear industries face some unique problems when handling, testing, or examining transducers and transmitters that have been radioactively contaminated. Although many people and organizations, including EG and G Idaho, have performed such work for many years, there are no set, structured approaches or procedures. This paper discusses a disciplined laboratory approach to contaminated transducer testing and evaluation, utilizing equipment and facilities developed specifically for this type of work

  10. In situ vitrification: Test results for a contaminated soil-melting process

    International Nuclear Information System (INIS)

    Buelt, J.L.; Timmerman, C.L.; Westsik, J.H. Jr.

    1989-10-01

    In situ vitrification (ISV) is being developed at Pacific Northwest Laboratory for the Department of Energy to stabilize soils and sludges that are contaminated with radioactive and hazardous chemical wastes. ISV is a process that immobilizes contaminated soil in place by converting it to a durable glass and crystalline product similar to obsidian and basalt. In June 1987, a large-scale test of the process was completed at a transuranic-contaminated soil site. The test constituted the first full-scale demonstration of ISV at an actual site. This paper summarizes the results of that test and describes the potential adaptation of the process to radioactive and hazardous chemical waste-contaminated soils. 15 refs., 9 figs., 3 tabs

  11. Radioactive contamination of some rubber or plastic surfaces by fission products. Decontamination tests

    International Nuclear Information System (INIS)

    Mestre, E.; Sautiez, N.

    1957-10-01

    With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)

  12. Decontamination tests on tritium-contaminated materials

    International Nuclear Information System (INIS)

    Boutot, P.; Schipfer, P.

    1967-01-01

    These tests are designed to try out various processes liable to be applied to the decontamination of a material contaminated with tritium. The samples are thin stainless- steel slabs contaminated in the laboratory with elements extracted from industrial installations. The measurement of the initial and residual activities is carried out using an open-window BERTHOLD counter. The best results are obtained by passing a current of pre-heated (300 deg. C) air containing water vapour. This process makes it possible to reach a decontamination factor of 99.5 per cent in 4 hours. In a vacuum, the operation has to be prolonged to 100 hours in order to obtain a decontamination factor of 99.2 per cent. Wet-chemical or electrolytic treatments are efficient but their use is limited by the inherent corrosion risks. A study of the reappearance of the contamination has made it possible to observe that this phenomenon occurs whatever the process used. (authors) [fr

  13. Land treatment testing of diesel contaminated soils using bioremediation

    Energy Technology Data Exchange (ETDEWEB)

    Demque, D E

    1994-01-01

    A study was carried out of degradation rates of diesel contaminated soil (10,000 ppM by weight of diesel to dry soil) under different treatment conditions and tillage rates over a 14 week testing period. A total of 10 treatment-tillage conditions were duplicated to provide confidence in the test results. Each test cell was built to contain 80 kg of contaminated soil with a drainage system. The 20 boxes were sampled on a weekly basis for the first 4 weeks, semimonthly for the following 6 weeks and at the end of 14 weeks. Each test consisted of 3 random total petroleum hydrocarbons (TPH) and 3 random BTEX samples per box. In addition, each box was monitored for leachate TPH, moisture content, microorganism concentration, and ground temperature. After the last samples were taken the underlying drainage layer was analyzed for TPH, and the boxes were checked for leaks. The tests revealed the effectiveness of the various treatment methods and tillage rates. Greatest degradation of diesel contaminated soil was obtained with the addition of nutrients and a frequent tillage rate. It was apparent that indigenous microorganisms adapted quickly to the diesel contaminant. Soil that was biostimulated with no drainage or bioaugmentation demonstrated that the addition of acclimated microorganisms had little effect on either the rate of degradation or the ultimate degradation achieved. Use of chlorine to inhibit biodegradation, allowing examination of other degradation mechanisms was effective for only ca 3 weeks, and had an adverse effect on TPH testing. 51 refs., 46 figs., 31 tabs.

  14. Uniaxial compression tests on diesel contaminated frozen silty soil specimens

    International Nuclear Information System (INIS)

    Chenaf, D.; Stampli, N.; Bathurst, R.; Chapuis, R.P.

    1999-01-01

    Results of a uniaxial, unconfined compression test on artificial diesel-contaminated and uncontaminated frozen silty soils are discussed. The testing program involved 59 specimens. The results show that for the same fluid content, diesel contamination reduced the strength of the frozen specimens by increasing the unfrozen water content. For example, in specimens containing 50 per cent diesel oil of the fluid content by weight the maximum strength was reduced by 95 per cent compared to the strength of an uncontaminated specimen. Diesel contamination was also shown to contribute to the slippage between soil particles by acting as a lubricant, thus accelerating the loss of compressive strength.13 refs., 18 figs

  15. Non-radioactive stand-in for radioactive contamination. I. Non-radioactive tests

    International Nuclear Information System (INIS)

    Rohe, M.J.; Rankin, W.N.; Postles, R.L.

    1985-01-01

    Candidate non-radioactive materials for use as a stand-in for radioactive contamination during application of a high-pressure, hot water decontamination were identified and evaluated. A stand-in for radioactive contamination is needed to evaluate the decontaminability of replacement canyon cranes at the manufacturers location where actual radioactive contamination cannot be used. This evaluation was conducted using high-pressure, hot-water at 420 psi, 190 0 F, and 20 gal/min through a 1/8-in.-diam nozzle, the decontamination technique preferred by SRP Separations Department for this application. A non-radioactive stand-in for radioactive contamination was desired that would be removed by direct blast stream contact but would remain intact on surfaces where direct contact does not occur. This memorandum describes identification of candidate non-radioactive stand-in materials and evaluation of these materials in screening tests and tests with high-pressure, hot-water blasting. The following non-radioactive materials were tested: carpenter's line chalk; typing correction fluid; dye penetrant developer; latex paint with attapulyite added; unaltered latex paint; gold enamel; layout fluid; and black enamel. Results show that blue layout fluid and gold enamel have similar adherence that is within the range expected for actual radioactive contamination. White latex paint has less adherence than expected for actual radioactive contamination. The film was removed at a rate of 2 . Black enamel has more adherence than expected from actual radioactive contamination. In these tests ASTM No. 2B surfaces were harder to clean than either ASTM No. 1 or electropolished surfaces which had similar cleaning properties. A 90 0 blast angle was more effective than a 45 0 blast angle. In these tests there was no discernible effect of blast distance between 1 and 3 ft

  16. Feasibility testing of in situ vitrification of uranium-contaminated soils

    International Nuclear Information System (INIS)

    Ikuse, H.; Tsuchino, S.; Tasaka, H.; Timmerman, C.L.

    1989-01-01

    Process feasibility studies using in situ vitrification (ISV) were successfully performed on two different uranium-contaminated wastes. In situ vitrification is a thermal treatment process that converts contaminated soils into durable glass and crystalline form. Of the two different wastes, one waste was uranium mill tailings, while the other was uranium-contaminated soils which had high water contents. Analyses of the data from the two tests are presented

  17. Testing of portal monitors for personnel contamination control

    International Nuclear Information System (INIS)

    Johnson, L.O.; Gupta, V.P.; Stevenson, R.L.; Stalker, A.C.; Baker, K.R.; Littleton, M.L.; Rich, B.L.

    1983-04-01

    This is a report of an INPO-funded evaluation of state-of-the-art portal monitors used to detect personnel contamination. The project developed techniques and procedures to evaluate the performance and sensitivity of the portal monitors which provided data for intercomparison. An additional accomplishment was development of a methodology to assist manufacturers and users to optimize the monitor settings, and to provide technical basis for the eventual use of fixed monitors to replace frisking for contamination control. The monitors tested utilize thin-window gas-flow proportional counters sensitive to beta and gamma radiation. Various tests were performed: (1) background count rate and the statistical variability, (2) detector efficiency at different distances, (3) moving source sensitivity for various size sources and speeds, and (4) false alarm rates at different background levels. A model has been developed for the moving source measurements to compare the experimental data, and to test whether it is possible to adequately model the behavior of a portal monitor response to a moving source. The model results with the actual test results are compared

  18. Cone penetrometer testing (CPT) for groundwater contamination

    International Nuclear Information System (INIS)

    Jordan, J.E.; Van Pelt, R.S.

    1993-01-01

    Over the past decade, researchers at the Savannah River Site (SRS) and elsewhere have greatly advanced the knowledge of waste site characterization technologies. As a result, many of the techniques used in the past to investigate waste sites have been replaced by newer technologies, designed to provide greater protection for human health and the environment, greater access to suspected zones of contamination, and more accurate information of subsurface conditions. Determining the most environmentally sound method of assessing a waste unit is a major component of the SRS environmental restoration program. In an effort to understand the distribution and migration of contaminants in the groundwater system, the cone penetrometer investigation of the A/M-Area Southern Sector was implemented. The program incorporated a phased approach toward characterization by first using the CPT to delineate the plume boundary, followed by installing groundwater monitoring wells. The study provided the additional hydrogeologic information necessary to better understand the nature and extent of the contaminant plume (Fig. 1) and the hydrogeologic system in the Southem Sector. This data is essential for the optimal layout of the planned groundwater monitoring well network and recovery system to remediate the aquifers in the area. A number of other test locations were selected in the area during this study for lithologic calibration of the tool and to collect confirmation water samples from the aquifer. Cone penetrometer testing and hydrocone sampling, were performed at 17 sites (Fig. 2). The hydrocone, a tool modification to the CPT, was used to collect four groundwater samples from confined aquifers. These samples were analyzed by SRS laboratories. Elevated levels of chlorinated compounds were detected from these samples and have aided in further delineating the southern sector contaminant plume

  19. Modeling to Support Groundwater Contaminant Boundaries for the Shoal Underground Nuclear Test

    Energy Technology Data Exchange (ETDEWEB)

    K. Pohlmann; G. Pohll; J. Chapman; A. Hassan; R. Carroll; C. Shirley

    2004-03-01

    The purpose of this work is to characterize groundwater flow and contaminant transport at the Shoal underground nuclear test through numerical modeling using site-specific hydrologic data. The ultimate objective is the development of a contaminant boundary, a model-predicted perimeter defining the extent of radionuclide-contaminated groundwater from the underground test throughout 1,000 years at a prescribed level of confidence. This boundary will be developed using the numerical models described here, after they are approved for that purpose by DOE and NDEP.

  20. Modeling to Support Groundwater Contaminant Boundaries for the Shoal Underground Nuclear Test

    International Nuclear Information System (INIS)

    K. Pohlmann; G. Pohll; J. Chapman; A. Hassan; R. Carroll; C. Shirley

    2004-01-01

    The purpose of this work is to characterize groundwater flow and contaminant transport at the Shoal underground nuclear test through numerical modeling using site-specific hydrologic data. The ultimate objective is the development of a contaminant boundary, a model-predicted perimeter defining the extent of radionuclide-contaminated groundwater from the underground test throughout 1,000 years at a prescribed level of confidence. This boundary will be developed using the numerical models described here, after they are approved for that purpose by DOE and NDEP

  1. In Situ Vitrification: Recent test results for a contaminated soil melting process

    International Nuclear Information System (INIS)

    Buelt, J.L.; Timmerman, C.L.; Westsik, J.H. Jr.

    1988-06-01

    In Situ Vitrification (ISV) is being developed at Pacific Northwest Laboratory for the Department of Energy and other clients for the stabilization of soils and sludges contaminated with radioactive and hazardous chemical wastes. ISV is a process that immobilizes contaminated soil in place by converting it to a durable glass and crystalline product that is similar to obsidian. In June 1987, a large-scale test of the process was completed at a transuranic- contaminated soil site. This constituted the first full-scale demonstration of the ISV process at an actual site. This paper summarizes the preliminary results of this test and describes the processes' potential adaptation to radioactive and hazardous chemical waste contaminated soils. 10 refs., 10 figs

  2. SOIL WASHING TREATABILITY TESTS FOR PESTICIDE- CONTAMINATED SOIL

    Science.gov (United States)

    The 1987 Sand Creek Operable Unit 5 record of decision (ROD) identified soil washing as the selected technology to remediate soils contaminated with high levels of organochlorine pesticides, herbicides, and metals. Initial treatability tests conducted to assess the applicability...

  3. Letter Report: Contaminant Boundary at the Shoal Underground Nuclear Test

    International Nuclear Information System (INIS)

    Greg Pohll; Karl Pohlmann

    2004-01-01

    As part of the corrective action strategy reached between the U.S. Department of Energy and the State of Nevada, the extent and potential impact of radionuclide contamination of groundwater at underground nuclear test locations must be addressed. This report provides the contaminant boundary for the Project Shoal Site, based on the groundwater flow and transport model for the site, by Pohlmann (and others)

  4. Terrestrial avoidance behaviour tests as screening tool to assess soil contamination

    International Nuclear Information System (INIS)

    Loureiro, Susana; Soares, Amadeu M.V.M.; Nogueira, Antonio J.A.

    2005-01-01

    To assess soil quality and risk assessment, bioassays can be useful tools to gauge the potential toxicity of contaminants focusing on their bioavailable fraction. A rapid and sublethal avoidance behaviour test was used as a screening tool with the earthworm Eisenia andrei and the isopod Porcellionides pruinosus, where organisms were exposed during 48 h to several chemicals (lindane, dimethoate and copper sulphate, for isopods and carbendazim, benomyl, dimethoate and copper sulphate for earthworms). Both species were also exposed to soils from an abandoned mine. For all bioassays a statistical approach was used to derive EC 50 values. Isopods and earthworms were able to perceive the presence of toxic compounds and escaping from contaminated to clean soil. Furthermore the behaviour parameter was equally or more sensitive then other sublethal parameters (e.g. reproduction or growth), expressing the advantages of Avoidance Behaviour Tests as screening tools in ERA. - Avoidance Behaviour Tests with earthworms and isopods can be used as screening tools in the evaluation of soil contamination

  5. Applicability of slug interference testing of hydraulic characterization of contaminated aquifer sites

    International Nuclear Information System (INIS)

    Spane, F.A.; Swanson, L.C.

    1993-10-01

    Aquifer test methods available for characterizing hazardous waste sites are sometimes restricted because of problems with disposal of contaminated groundwater. These problems, in part, have made slug tests a more desirable method of determining hydraulic properties at such sites. However, in higher permeability formations (i.e., transmissivities ≥ 1 x 10 -3 m 2 /s), slug test results often cannot be analyzed and give, at best, only a lower limit for transmissivity. A need clearly exists to develop test methods that can be used to characterize higher permeability aquifers without removing large amounts of contaminated groundwater. One hydrologic test method that appears to hold promise for characterizing such sites is the slug interference test. To assess the applicability of this test method for use in shallow alluvial aquifer systems, slug interference tests have been conducted, along with more traditional aquifer testing methods, at several Hanford multiple-well sites. Transmissivity values estimated from the slug interference tests were comparable (within a factor of 2 to 3) to values calculated using traditional testing methods, and made it possible to calculate the storativity or specific yield for the intervening test formation. The corroboration of test results indicates that slug interference testing is a viable hydraulic characterization method in transmissive alluvial aquifers, and may represent one of the few test methods that can be used in sensitive areas where groundwater is contaminated

  6. Algal tests with soil suspensions and elutriates: A comparative evaluation for PAH contaminated soils

    DEFF Research Database (Denmark)

    Baun, Anders; Justesen, Kasper Bo; Nyholm, Niels

    2002-01-01

    An algal growth inhibition test procedure with soil suspensions is proposed and evaluated for PAH-contaminated soil. The growth rate reduction of the standard freshwater green alga Pseudokirchneriella subcapitata (formerly known as Selenastrum capricornutum) was used as the toxicity endpoint......, and was quantified by measuring the fluorescence of solvent-extracted algal pigments. No growth rate reduction was detected for soil contents up to 20 g/l testing five non-contaminated Danish soils. Comparative testing with PAH-contaminated soil elutriates and soil suspensions showed that the suspensions had...

  7. Environmental simulation testing of solar cell contamination by hydrazine

    Science.gov (United States)

    Moore, W. W., Jr.

    1972-01-01

    Test results for thermal vacuum and radiation environment simulation of hydrazine contamination are discussed. Solar cell performance degradation, measured by short circuit current, is presented in correlation with the variations used in environmental parameters.

  8. A quick rhizobacterial selection tests for the remediation of copper contaminated soils.

    Science.gov (United States)

    Braud, A M; Hubert, M; Gaudin, P; Lebeau, T

    2015-08-01

    The main objective of the study is to develop and improve quick bacterial tests to select the best candidates for the bioaugmentation of metal-contaminated soil, coupled with phytoextraction. Bacteria isolates (181) were selected from a collection originated from a Cu-contaminated sediment, on the basis of several miniaturized biochemical tests adapted to the copper contamination. Amongst them, we used a growth soil based-medium to select metal-tolerant bacteria, and their ability to grow and mobilize metals by mean of metabolites (siderophores, organic acids) was also assessed. The result of the bacterial selection tests showed differences in presence or absence of copper, especially for phosphate-solubilizing strains which ability decreased by 53% in the presence of copper hydroxide phosphate as compared to the standard tricalcium phosphate test. A promising Pseudomonas putida was selected from the collection. The study underlined the importance of choosing significant selection tests regarding the nature of the metal occurring in the soil to be cleaned-up to assess the real potential of each bacterial strain for subsequent soil bioaugmentation purposes. © 2015 The Society for Applied Microbiology.

  9. 9 CFR 381.94 - Contamination with Microorganisms; process control verification criteria and testing; pathogen...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Contamination with Microorganisms... § 381.94 Contamination with Microorganisms; process control verification criteria and testing; pathogen... maintaining process controls sufficient to prevent fecal contamination. FSIS shall take further action as...

  10. 78 FR 37463 - Expedited Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe...

    Science.gov (United States)

    2013-06-21

    ... Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe Drinking Water Act... page 32570, with the table entitled ``ALTERNATIVE TESTING METHODS FOR CONTAMINANTS LISTED AT 40 CFR 141... Contaminants Listed at 40 CFR 141.25(a) SM 21st Edition SM 22nd Edition Contaminant Methodology \\1\\ \\28\\ ASTM...

  11. Radioactive contamination of former Semipalatinsk test site area

    International Nuclear Information System (INIS)

    Artem'ev, O.I.; Akhmetov, M.A.; Ptitskaya, L.D.

    2001-01-01

    The nuclear weapon infrastructure elimination activities and related surveys of radioactive contamination are virtually accomplished at the Semipalatinsk test site (STS). The radioecological surveys accompanied closure of tunnels which were used for underground nuclear testing at Degelen technical field and elimination of intercontinental ballistic missile silo launchers at Balapan technical field. At the same time a ground-based route survey was carried out at the Experimental Field where aboveground tests were conducted and a ground-based area survey was performed in the south of the test site where there are permanent and temporary inhabited settlements. People dwelling these settlements are mainly farmers. The paper presents basic results of radiological work conducted in the course of elimination activities. (author)

  12. Cleanup procedures at the Nevada Test Site and at other radioactively contaminated sites including representative costs of cleanup and treatment of contaminated areas

    International Nuclear Information System (INIS)

    Talmage, S.S.; Chilton, B.D.

    1987-09-01

    This review summarizes available information on cleanup procedures at the Nevada Test Site and at other radioactively contaminated sites. Radionuclide distribution and inventory, size of the contaminated areas, equipment, and cleanup procedures and results are included. Information about the cost of cleanup and treatment for contaminated land is presented. Selected measures that could be useful in estimating the costs of cleaning up radioactively contaminated areas are described. 76 refs., 16 tabs

  13. Performance testing of the sediment-contaminant transport model, SERATRA, at different rivers

    International Nuclear Information System (INIS)

    Onishi, Y.; Yabusaki, S.B.; Kincaid, C.T.

    1982-04-01

    Mathematical models of sediment-contaminant migration in surface water must account for transport, intermedia transfer, decay and degradation, and transformation processes. The unsteady, two dimensional, sediment-contaminant transport code, SERATRA (Onishi, Schreiber and Codell 1980) includes these mechanisms. To assess the accuracy of SERATRA to simulate the sediment-contaminant transport and fate processes, the code was tested against one-dimensional analytical solutions, checked for its mass balance, and applied to field sites. The field application cases ranged from relatively simple, steady conditions to unsteady, nonuniform conditions for large, intermediate, and small rivers. It was found that SERATRA is capable of simulating sediment-contaminant transport under a wide range of conditions

  14. Aging tests of ethylene contaminated argon/ethane

    International Nuclear Information System (INIS)

    Atac, M.; Bauer, G.

    1994-01-01

    We report on aging tests of argon/ethane gas with a minor (1800 ppM) component of ethylene. The measurements were first conducted with the addition of alcohol to test the suppression of aging by this additive, with exposure up to ∼1.5 C/cm. Tests have included: a proportional tube with ethanol, another with isopropyl alcohol, and for comparison a tube has also been run with ethanol and argon/ethane from CDF's old (ethylene-free) ethane supply. The aging test with ethanol showed no difference between the ethylene-free and the ethylene tube. Furthermore, raw aging rates of argon/ethane and argon/ethane/ethylene were measured by exposing tubes without the addition of alcohol to about 0.1 C/cm. Again, no significant difference was observed. In conclusion, we see no evidence that ethylene contamination up to 1800 ppM has any adverse effect on wire aging. However, this level of ethylene does seem to significantly suppress the gas gain

  15. The field application of an immunoassay-based test for petroleum fuels contamination in groundwater

    International Nuclear Information System (INIS)

    Carter, K.R.

    1994-01-01

    The recent development of low-cost, rapid field analytical tests for petroleum fuels based on immunoassay technology has provided an on-site tool for the cost-effective, accurate assessment of groundwater contamination. The method allows for rapid, direct measurement of contaminant concentration. The method has been used for a variety of applications including surface water runoff testing and groundwater monitoring well siting. The PETRO RISc Water Test can be used to substantially reduce the cost of monitoring well installation. Current, monitoring wells are placed based on knowledge of the location of the source of contamination, the size of the release, the time elapsed since the release began, and the hydrogeology of the site. While the location of the source is generally known with some precision, the hydrogeology of the site and the timing of the release rarely are. This results in the need for an ''educated guess'' regarding the drilling location for monitoring wells that are installed to provide long term feedback on groundwater contamination. The tests have the greatest sensitivity to aliphatic compounds in the range of six to ten carbons and aromatic compounds such as toluene, xylene, and naphthalene

  16. A review of centrifugal testing of gasoline contamination and remediation.

    Science.gov (United States)

    Meegoda, Jay N; Hu, Liming

    2011-08-01

    Leaking underground storage tanks (USTs) containing gasoline represent a significant public health hazard. Virtually undetectable to the UST owner, gasoline leaks can contaminate groundwater supplies. In order to develop remediation plans one must know the extent of gasoline contamination. Centrifugal simulations showed that in silty and sandy soils gasoline moved due to the physical process of advection and was retained as a pool of free products above the water table. However, in clayey soils there was a limited leak with lateral spreading and without pooling of free products above the water table. Amount leaked depends on both the type of soil underneath the USTs and the amount of corrosion. The soil vapor extraction (SVE) technology seems to be an effective method to remove contaminants from above the water table in contaminated sites. In-situ air sparging (IAS) is a groundwater remediation technology for contamination below the water table, which involves the injection of air under pressure into a well installed into the saturated zone. However, current state of the art is not adequate to develop a design guide for site implementation. New information is being currently generated by both centrifugal tests as well as theoretical models to develop a design guide for IAS. The petroleum contaminated soils excavated from leaking UST sites can be used for construction of highway pavements, specifically as sub-base material or blended and used as hot or cold mix asphalt concrete. Cost analysis shows that 5% petroleum contaminated soils is included in hot or cold mix asphalt concrete can save US$5.00 production cost per ton of asphalt produced.

  17. A Review of Centrifugal Testing of Gasoline Contamination and Remediation

    Directory of Open Access Journals (Sweden)

    Jay N. Meegoda

    2011-08-01

    Full Text Available Leaking underground storage tanks (USTs containing gasoline represent a significant public health hazard. Virtually undetectable to the UST owner, gasoline leaks can contaminate groundwater supplies. In order to develop remediation plans one must know the extent of gasoline contamination. Centrifugal simulations showed that in silty and sandy soils gasoline moved due to the physical process of advection and was retained as a pool of free products above the water table. However, in clayey soils there was a limited leak with lateral spreading and without pooling of free products above the water table. Amount leaked depends on both the type of soil underneath the USTs and the amount of corrosion. The soil vapor extraction (SVE technology seems to be an effective method to remove contaminants from above the water table in contaminated sites. In-situ air sparging (IAS is a groundwater remediation technology for contamination below the water table, which involves the injection of air under pressure into a well installed into the saturated zone. However, current state of the art is not adequate to develop a design guide for site implementation. New information is being currently generated by both centrifugal tests as well as theoretical models to develop a design guide for IAS. The petroleum contaminated soils excavated from leaking UST sites can be used for construction of highway pavements, specifically as sub-base material or blended and used as hot or cold mix asphalt concrete. Cost analysis shows that 5% petroleum contaminated soils is included in hot or cold mix asphalt concrete can save US$5.00 production cost per ton of asphalt produced.

  18. Radiostrontium contamination of soil and vegetation within the Semipalatinsk test site.

    Science.gov (United States)

    Howard, B J; Semioschkina, N; Voigt, G; Mukusheva, M; Clifford, J

    2004-12-01

    The Semipalatinsk nuclear test site (STS) in the Republic of Kazakhstan was an important site for testing atomic bombs and other civil and military nuclear devices of the former Soviet Union. Results are presented from investigations on the extent of radiostrontium contamination in soils and vegetation at the technical areas of the STS, where the tests were conducted and in pastures used by farmers for grazing animals or for hay production. Our data are compared with those reported largely in the recent Russian language literature that has been reviewed. The extent of (90)Sr contamination of soil is highly variable over the STS with the highest values associated with the technical areas, particularly the Degelen mountains. Recently measured values in both the present data and the Russian language literature confirm the relatively high current contamination of soil and vegetation in the vicinity of tunnels and associated watercourses in the Degelen area. The proportion of (90)Sr in soil which could not be extracted with 6 M HCl was only an average of 20%, which is low compared to other test site areas and possibly indicates a relatively high mobility in this area, because the (90)Sr is derived from leakage from explosion tunnels along watercourses rather than being associated with fused silicates. A comparison of relative activity concentrations in soil and vegetation suggests that the transfer of (90)Sr to vegetation on the STS is high compared to that of (137)Cs and plutonium.

  19. Engineering-scale tests of in situ vitrification to PCB and radioactive contaminated soils

    International Nuclear Information System (INIS)

    Liikala, S.C.

    1991-01-01

    In Situ Vitrification (ISV) is a thermal treatment technology applicable to the remediation of hazardous chemical and radioactive contaminated soil and sludge sites. The ISV process utilizes electricity, through joule heating, to melt contaminated soil and form an inert glass and microcrystalline residual product. Applications of ISV to polychlorinated biphenyls (PCBs) and radionuclides have been demonstrated at engineering-scale in numerous tests (1,2,3). An updated evaluation of ISV applicability to treatment of PCBs and radionuclides, and recent test results are presented herein

  20. Assisted bioremediation tests on three natural soils contaminated with benzene

    Directory of Open Access Journals (Sweden)

    Maria Manuela Carvalho

    2015-07-01

    Full Text Available Bioremediation is an attractive and useful method of remediation of soils contaminated with petroleum hydrocarbons because it is simple to maintain, applicable in large areas, is economic and enables an effective destruction of the contaminant. Usually, the autochthone microorganisms have no ability to degrade these compounds, and otherwise, the contaminated sites have inappropriate environmental conditions for microorganism’s development. These problems can be overcome by assisted bioremediation (bioaugmentation and/or biostimulation. In this study the assisted bioremediation capacity on the rehabilitation of three natural sub-soils (granite, limestone and schist contaminated with benzene was evaluated. Two different types of assisted bioremediation were used: without and with ventilation (bioventing. The bioaugmentation was held by inoculating the soil with a consortium of microorganisms collected from the protection area of crude oil storage tanks in a refinery. In unventilated trials, biostimulation was accomplished by the addition of a nutrient mineral media, while in bioventing oxygen was also added. The tests were carried out at controlled temperature of 25 ºC in stainless steel columns where the moist soil contaminated with benzene (200 mg per kg of soil occupied about 40% of the column’s volume. The processes were daily monitored in discontinued mode. Benzene concentration in the gas phase was quantified by gas chromatography (GC-FID, oxygen and carbon dioxide concentrations were monitored by respirometry. The results revealed that the three contaminated soils were remediated using both technologies, nevertheless, the bioventing showed faster rates. With this work it was proved that respirometric analysis is an appropriate instrument for monitoring the biological activity.

  1. Contaminated metallic melt volume reduction testing

    International Nuclear Information System (INIS)

    Deichman, J.L.

    1981-01-01

    Laboratory scale metallic melts (stainless steel) were accomplished in support of Decontamination and Decommissioning's (D and D) contaminated equipment volume reduction and Low-Level Lead Site Waste programs. Six laboratory scale melts made with contaminated stainless steel provided data that radionuclide distribution can be predicted when proper temperature rates and ranges are employed, and that major decontamination occurs with the use of designed slagging materials. Stainless steel bars were contaminated with plutonium, cobalt, cesium and europium. This study was limited to stainless steel, however, further study is desirable to establish data for other metals and alloys. This study represents a positive beginning in defining the feasibility of economical volume reduction or conversion from TRU waste forms to LLW forms for a large portion of approximately 50 thousand tons of contaminated metal waste now being stored at Hanford underground or in deactivated facilities

  2. Test plan for the field evaluation and demonstration of the Contamination Control Unit

    International Nuclear Information System (INIS)

    Winberg, M.R.; Thompson, D.N.

    1993-06-01

    This report describes test details of a full demonstration of the Contamination Control Unit (CCU). The CCU is a mobile trailer capable of employing the use of soil fixatives, dust suppression agents, misting, and vacuum systems. These systems can perform a large number of contamination control functions to support the Office of Waste Technology Development (OTD) Buried Waste Integrated Demonstration (BWID) projects, transuranic (TRU) waste retrieval operations, and emergency response for hazardous and radioactive materials incidents. The demonstration will include both performance testing at the North Holmes Laboratory Facility (NHLF) and field testing in conjunction with the Remote Excavation System Demonstration at the Cold Test Pit. The NHLF will test operational parameters using water only, and the field demonstration at the Cold Test Pit involves full scale operation of vacuum, fixant, misting, and dust suppression systems. Test objectives, detailed experimental procedures, and data quality objectives necessary to perform the field demonstration are included in this test plan

  3. EP toxicity testing of lead to resolve disposition of radioactively contaminated lead

    International Nuclear Information System (INIS)

    Larsen, M.M.; Boehmer, A.M.

    1986-03-01

    The Department of Energy (DOE), in its efforts to comply with the requirements of the Resource Conservation and Recovery Act (RCRA) of 1976, is concerned with hazardous waste which is also radioactively contaminated. There are no existing facilities to treat or dispose of these wastes. One such waste is lead, which is extensively used in the nuclear industry as shielding. This paper reports the results of leach testing of lead (both solid lead samples and lead shot) to resolve questions as to whether or not radioactively contaminated waste lead must be treated as a hazardous waste. The results of these tests showed that: some samples passed the leach test. Results of development efforts performed to date to recycle lead and those planned for the future are included in this report

  4. Rain and contamination tests on HVDC wall bushings with and without RTV coatings

    International Nuclear Information System (INIS)

    Schneider, H.M.; Hall, J.F.; Nellis, C.L.; Low, S.S.; Lorden, D.J.

    1991-01-01

    In this paper results of tests made to determine the ability of room temperature vulcanized (RTV) silicone rubber coatings to improve the performance of HVDC wall bushings are described. The behavior of uncoated full scale ± 500 kV wall bushings is first determined in wetting conditions consisting of nonuniform rain and fog with various amounts of pre-deposited surface contamination. Parameters affecting flashover performance, such as polarity, rain conductivity, and contamination severity are discussed. Results of nonuniform rain tests on an RTV coated wall bushing are reported

  5. Radioactive contamination of some rubber or plastic surfaces by fission products. Decontamination tests; Contamination radioactive de quelques surfaces en caoutchouc ou en matiere plastique par des produits de fission. Essais de decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Mestre, E.; Sautiez, N.

    1957-10-15

    With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)

  6. Detecting Chloride Contamination of Objects and Buildings – Evaluating a New Testing Process

    Directory of Open Access Journals (Sweden)

    Lynda Skipper

    2018-02-01

    Full Text Available Soluble salts play a key factor in damage to a variety of materials, including stone, ceramics and metals. Particularly, salt contamination can lead to weakening of porous materials through salt crystallisation events, and increases the rate of metal corrosion. Over time, this results in physical damage to affected objects and buildings. It is therefore important to be able to monitor the salt content of materials, in order to understand levels of salt contamination and the potential for damage to occur. This research discusses the further development of the testing method for surface chlorides originally proposed by Piechota and Drake Piechota (2016 in their article “A simple survey kit for chloride detection on cuneiform tablets and other collections”. It introduces new and revised steps into the original protocol in order to make the achieved results semi-quantifiable, as well as identifying the limits of detection of the test kit. A comparison to alternative testing methods showed that comparable results were achievable using this methodology. The revised methodology was tested for efficacy on a range of salt contaminated objects, as well as on samples from buildings.

  7. Understanding Contamination; Twenty Years of Simulating Radiological Contamination

    Energy Technology Data Exchange (ETDEWEB)

    Emily Snyder; John Drake; Ryan James

    2012-02-01

    A wide variety of simulated contamination methods have been developed by researchers to reproducibly test radiological decontamination methods. Some twenty years ago a method of non-radioactive contamination simulation was proposed at the Idaho National Laboratory (INL) that mimicked the character of radioactive cesium and zirconium contamination on stainless steel. It involved baking the contamination into the surface of the stainless steel in order to 'fix' it into a tenacious, tightly bound oxide layer. This type of contamination was particularly applicable to nuclear processing facilities (and nuclear reactors) where oxide growth and exchange of radioactive materials within the oxide layer became the predominant model for material/contaminant interaction. Additional simulation methods and their empirically derived basis (from a nuclear fuel reprocessing facility) are discussed. In the last ten years the INL, working with the Defense Advanced Research Projects Agency (DARPA) and the National Homeland Security Research Center (NHSRC), has continued to develop contamination simulation methodologies. The most notable of these newer methodologies was developed to compare the efficacy of different decontamination technologies against radiological dispersal device (RDD, 'dirty bomb') type of contamination. There are many different scenarios for how RDD contamination may be spread, but the most commonly used one at the INL involves the dispersal of an aqueous solution containing radioactive Cs-137. This method was chosen during the DARPA projects and has continued through the NHSRC series of decontamination trials and also gives a tenacious 'fixed' contamination. Much has been learned about the interaction of cesium contamination with building materials, particularly concrete, throughout these tests. The effects of porosity, cation-exchange capacity of the material and the amount of dirt and debris on the surface are very important factors

  8. Biological and chemical tests of contaminated soils to determine bioavailability and environmentally acceptable endpoints (EAE)

    International Nuclear Information System (INIS)

    Montgomery, C.R.; Menzie, C.A.; Pauwells, S.J.

    1995-01-01

    The understanding of the concept of bioavailability of soil contaminants to receptors and its use in supporting the development of EAE is growing but still incomplete. Nonetheless, there is increased awareness of the importance of such data to determine acceptable cleanup levels and achieve timely site closures. This presentation discusses a framework for biological and chemical testing of contaminated soils developed as part of a Gas Research Institute (GRI) project entitled ''Environmentally Acceptable Endpoints in Soil Using a Risk Based Approach to Contaminated Site Management Based on Bioavailability of Chemicals in Soil.'' The presentation reviews the GRI program, and summarizes the findings of the biological and chemical testing section published in the GRI report. The three primary components of the presentation are: (1) defining the concept of bioavailability within the existing risk assessment paradigm, (2) assessing the usefulness of the existing tests to measure bioavailability and test frameworks used to interpret these measurements, and (3) suggesting how a small selection of relevant tests could be incorporated into a flexible testing scheme for soils to address this issue

  9. Breached fuel pin contamination from Run Beyond Cladding Breach (RBCB) tests in EBR-II

    International Nuclear Information System (INIS)

    Colburn, R.P.; Strain, R.V.; Lambert, J.D.B.; Ukai, S.; Shibahara, I.

    1988-09-01

    Studies indicate there may be a large economic incentive to permit some continued reactor operation with breached fuel pin cladding. A major concern for this type of operation is the potential spread of contamination in the primary coolant system and its impact on plant maintenance. A study of the release and transport of contamination from naturally breached mixed oxide Liquid Metal Reactor (LMR) fuel pins was performed as part of the US Department of Energy/Power Reactor and Nuclear Fuel Development Corporation (DOE/PNC) Run Beyond Cladding Breach (RBCB) Program at EBR-II. The measurements were made using the Breached Fuel Test Facility (BFTF) at EBR-II with replaceable deposition samplers located approximately 1.5 meters from the breached fuel test assemblies. The effluent from the test assemblies containing the breached fuel pins was routed up through the samplers and past dedicated instrumentation in the BFTF before mixing with the main coolant flow stream. This paper discusses the first three contamination tests in this program. 2 refs., 5 figs., 2 tabs

  10. Development of simulated contamination (SIMCON) and miscellaneous decontamination scoping tests

    International Nuclear Information System (INIS)

    Demmer, R.L.

    1994-01-01

    This report details the development of a method of simulating ICPP type contamination (SIMCON) with surrogate, nonradioactive materials and some miscellaneous testing and results that were completed using SIMCON. An analysis of historical ICPP decontamination samples is given, along with the justification relating SIMCON to this historical data. Some SIMCON testing of the following methods are given as miscellaneous examples: water rinse, water ultrasonic, cerric nitrate, CO 2 snowflake blasting, nitrogen ''Cryogenic'' blasting and strippable coating removal

  11. DTPA therapy of lung contaminations: testing a self contained aerosol generator

    International Nuclear Information System (INIS)

    Ducousso, R.; Pasquier, C.

    1975-01-01

    It has been shown how much the effectiveness of DTPA therapy of respiratory contamination decreased when the delay of administration of the product increased. Moreover, the effectiveness of local administration of the chelating agent as aerosol has been widely recognized. Owing to both the therapeutic urgency and the local administration, an individual pocket apparatus allowing emergency DTPA inhalation, on the spot of the accident was tried. A turbo-inhalator sold for the administration of an anti-asthmatic powder was tested, using DTPA powder inhaled by a volunteer previously contaminated by a 140 LaCl 3 aerosol [fr

  12. Use of bioassays for testing soils and/or sediments contaminated by mining activities

    Science.gov (United States)

    Pérez-Sirvent, C.; Martínez-Sánchez, M. J.; García-Lorenzo, M. L.; Molina, J.

    2009-04-01

    Ecotoxicity tests measure the bioavailability of the contaminants and the effects of the chemically not measured toxic compounds on the members of the soil community. Therefore, ecotoxicological testing may be a useful approach for assessing the toxicity as a complement to chemical analysis. They are solid phase tests based on terrestrial methods and tests performed on water extracts using aquatic test protocols. The extent and degree of heavy metal contamination around mines may vary depending on geochemical characteristics, the mineralization of tailings, physico-chemical conditions and the processes used to extract metals. Portman Bay was subject to mining from the time of the Roman Empire to 1991 when the activity ceased. Since 1957, the wastes from mining operations were discharged directly into the sea. These wastes mainly consisted of clay, quartz, siderite, magnetite, remains of sphalerite, pyrite and galena and residues of the chemical reagents used in floatation. In our study two methods of environmental toxicological tests were compared and applied to sediments of the Portman Bay (SE, Spain): the standardized toxicological test based on inhibition of luminescence employing Microtox

  13. ENVIRONMENTAL CONTAMINATION FROM WEAPON TESTS

    Energy Technology Data Exchange (ETDEWEB)

    none

    1958-10-01

    The program of the Atomic Energy Commission on environmental contamination from weapons tests is designed for the overall evaluation of the hazard to humans from test operations. It is limited to studies of the deposition of activity at long range rather than the problems associated with immediate, close-in fallout. The program has largely been a study of Sr{sup 90}, since considerations based on experience and measurement indicate that it is the isotope of greatest potential hazard. Data are presented pertinent to the monitoring of long-range fallout, particularly Sr{sup 90} and Cs{sup 137}. Values are tabulated for the fallout deposition, air concentrations, water concentrations, and the amounts in foods and human bone. In addition, results are given for some experimental investigations. The report of these results is not interpretative although certain papers that do attempt to interpret the present situation with respect to Sr{sup 90} in particular are reprinted. Bibliographies are presented covering the period since the 1957 hearings before the Joint Committee on Atomic Energy concerning the nature of radioactive fallout and its effects on man. A document list of submissions to the United Nations Scientific Committee on the Effects of Atomic Radiation is given to illustrate the work done in other countries. Several papers on the subject, which have not been generally available, are reprinted.

  14. TESTING ANTIMICROBIAL CLEANER EFFICACY ON GYPSUM WALLBOARD CONTAMINATED WITH STACHYBOTRYS CHARTARUM

    Science.gov (United States)

    Reducing occupant exposure to indoor mold growth is the goal of this research, through the efficacy testing of antimicrobial cleaners. Often mold contaminated building materials are not properly removed, but instead surface cleaners are applied in an attempt to alleviate the prob...

  15. Modeling to Support Groundwater Contaminant Boundaries for the Shoal Underground Nuclear Test

    Energy Technology Data Exchange (ETDEWEB)

    K. Pohlmann; G. Pohll; J. Chapman; A. Hassan; R. Carroll; C. Shirley

    2004-03-01

    Groundwater flow and radionuclide transport at the Shoal underground nuclear test are characterized using three-dimensional numerical models, based on site-specific hydrologic data. The objective of this modeling is to provide the flow and transport models needed to develop a contaminant boundary defining the extent of radionuclide-contaminated groundwater at the site throughout 1,000 years at a prescribed level of confidence. This boundary will then be used to manage the Project Shoal Area for the protection of the public and the environment.

  16. TESTING ANTIMICROBIAL PAINT EFFICACY ON GYPSUM WALLBOARD CONTAMINATED WITH STACHYBOTRYS CHARTARUM

    Science.gov (United States)

    Often mold contaminated building materials are not properly removed, some surface cleaning is performed and paint is applied in an attempt to alleviate the problem. The efficacy of antimicrobial paints to eliminate or control mold regrowth on surfaces can easily be tested on non-...

  17. 75 FR 32295 - Expedited Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe...

    Science.gov (United States)

    2010-06-08

    ... Approval of Alternative Test Procedures for the Analysis of Contaminants Under the Safe Drinking Water Act... methods for use in measuring the levels of contaminants in drinking water and determining compliance with... required to measure contaminants in drinking water samples. In addition, EPA Regions as well as States and...

  18. This is Sandia

    Energy Technology Data Exchange (ETDEWEB)

    1995-02-01

    Sandia is a multiprogram engineering and science laboratory operated for the Department of Energy with major facilities at Albuquerque, New Mexico, and Livermore, California, and a test range near Tonapah, Nevada. It has major research and development responsibilities for nuclear weapons, arms control, energy, the environment, economic competitiveness, and other areas of importance to the needs of the nation. The principal mission is to support national defense policies by ensuring that the nuclear weapon stockpile meets the highest standards of safety, reliability, security, use control, and military performance. This publication gives a brief overview of the multifaceted research programs conducted by the laboratory.

  19. Evaluation of various tests for the diagnosis of soil contamination by 2,4,5-trichlorophenol (2,4,5-TCP)

    International Nuclear Information System (INIS)

    Bello, D.; Trasar-Cepeda, C.; Leiros, M.C.; Gil-Sotres, F.

    2008-01-01

    Soil response to contamination with 2,4,5-triclorophenol was studied to test the validity of the concept of Generic Reference Levels (GRL), the main criterion used to define soil contamination. Soil samples were artificially contaminated with doses between 0 and 5000 mg kg -1 of 2,4,5-triclorophenol, and analysed by various tests. Where possible, the response of soils to the contaminant was modelled by a sigmoidal dose-response curve in order to estimate the ED 50 values. The tests provided different responses, but only microbial biomass-C and dehydrogenase and urease activities demonstrated soil deterioration in response to contamination. The results suggest that the diagnosis of soil contamination has been greatly simplified in the legislation by the provision of a single figure for each compound, and that the GRL concept could perhaps be substituted by measurement of ED 50 values, which better reflect the alteration of a soil due to the presence of a xenobiotic substance. - The concentration of a toxic substance present in a soil cannot be considered as the only criteria to classify such soil as contaminated

  20. Tritium contaminated waste management at the tritium systems test assembly

    International Nuclear Information System (INIS)

    Jalbert, R.A.; Carlson, R.V.

    1987-01-01

    The Tritium Systems Test Assembly (TSTA) at Los Alamos continues to move toward full operation of an integrated, full-sized, computer-controlled fusion fuel processing loop. Concurrent nonloop experiments further the development of advanced tritium technologies and handling methods. Since tritium operations began in June 1984, tritium contaminated wastes have been produced at TSTA that are roughly typical in kind and amount of those to be produced by tritium fueling operations at fusion reactors. Methods of managing these wastes are described, including information on some methods of decontamination so that equipment can be reused. Data are given on the kinds and amounts of wastes and the general level of contamination. Also included are data on environmental emissions and doses to personnel that have resulted from TSTA operations. Particular problems in waste managements are discussed

  1. Respiration testing for bioventing and biosparging remediation of petroleum contaminated soil and ground water

    International Nuclear Information System (INIS)

    Gray, A.L.; Brown, A.; Moore, B.J.; Payne, R.E.

    1996-01-01

    Respiration tests were performed to measure the effect of subsurface aeration on the biodegradation rates of petroleum hydrocarbon contamination in vadose zone soils (bioventing) and ground water (biosparging). The aerobic biodegradation of petroleum contamination is typically limited by the absence of oxygen in the soil and ground water. Therefore, the goal of these bioremediation technologies is to increase the oxygen concentration in the subsurface and thereby enhance the natural aerobic biodegradation of the organic contamination. One case study for biosparging bioremediation testing is presented. At this site atmospheric air was injected into the ground water to increase the dissolved oxygen concentration in the ground water surrounding a well, and to aerate the smear zone above the ground water table. Aeration flow rates of 3 to 8 cfm (0.09 to 0.23 m 3 /min) were sufficient to increase the dissolved oxygen concentration. Petroleum hydrocarbon biodegradation rates of 32 to 47 microg/l/hour were calculated based on measurements of dissolved oxygen concentration in ground water. The results of this test have demonstrated that biosparging enhances the biodegradation of petroleum hydrocarbons, but the results as they apply to remediation are not known. Two case studies for bioventing respiration testing are presented

  2. Demonstration test on decontamination of contaminated pool water using liquid-solid settling technology with flocculants

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Adachi, Toshihiro; Watanabe, Noriyuki; Tagawa, Akihiro; Hosobuchi, Shigeki; Takanashi, Junko

    2013-01-01

    For the purpose of supplying agricultural water, a stationary purification system for contaminated water had been developed on the basis of the liquid-solid settling technology using flocculants. Two kinds of flocculants had been developed on the basis of preliminary tests: one that compounds iron ferrocyanide and the other that does not. With the use of this system and flocculants, a demonstration test was conducted to apply the decontamination technology on contaminated water in two swimming pools in an elementary school located at Motomiya City, Fukushima Prefecture, Japan. It is proved from the results that both the developed purification system and the flocculants can be established as a practicable decontamination technology for contaminated water: the treatment rate was 10 m 3 /hour and the elimination factor of radioactive materials was higher than 99%. (author)

  3. Development of a suitable test method for evaluating the toxicity of contaminated soils to earthworms in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Stephenson, G.L. [Univ. of Guelph, Ontario (Canada); Scroggins, R. [Environment Canada, Gloucester, Ontario (Canada). Method Development and Application Section

    1995-12-31

    Environment Canada has embarked on a five year program to develop, standardize, and validate a battery of soil toxicity tests which can be used to assess the relative toxicity of contaminants in soils to terrestrial organisms. These tests must be applicable to soil conditions typically found in Canadian environments and the test species must be representative of the species of soil invertebrates or plants inhabiting soil ecosystems in Canada. One of the toxicity tests being developed is designed to assess the toxicity of contaminated soils to earthworms. Five of the potential test species belong to the Lumbricidae family and include the Canadian worm (Allobophora calignosa/Aporrectodea tuberculate), the European bark worm (Dendrodtilus rubidus (rubida)), the pink soil worm (Eisenia rosea), the red marsh worm (Lumbricus rubellus), and the Canadian night crawler or dew worm (Lumbricus terrestris). The sixth species, the white pot worm (Enchytraeus albidus), belongs to the Enchytraeidae family. Further assessment reduced the number of representative species to three. Most earthworm test methods have been developed to assess the toxicity of chemically-spiked artificial soils to Eisenia fetida or E. andrei. Test methods have also been developed to assess the relative toxicity of contaminated soils from hazardous waste sites. Comparative acute toxicity data for three species of earthworm exposed to a hydrocarbon contamination will be presented. Comparative toxicity data for the same three species of earthworm will also be presented using test procedures and conditions that have been modified to accommodate biological differences among the species of earthworm. Recommendations regarding test design, methods, and conditions optimal for each test species will be summarized and discussed with respect to the precision of test results.

  4. Root cause investigation of a viral contamination incident occurred during master cell bank (MCB) testing and characterization--a case study.

    Science.gov (United States)

    Chen, Dayue; Nims, Raymond; Dusing, Sandra; Miller, Pamela; Luo, Wen; Quertinmont, Michelle; Parekh, Bhavin; Poorbaugh, Josh; Boose, Jeri Ann; Atkinson, E Morrey

    2008-11-01

    An adventitious agent contamination occurred during a routine 9 CFR bovine viral screening test at BioReliance for an Eli Lilly Chinese Hamster Ovary (CHO) cell-derived Master Cell Bank (MCB) intended for biological production. Scientists from the sponsor (Eli Lilly and Company) and the testing service company (BioReliance) jointly conducted a systematic investigation in an attempt to determine the root cause of the contamination. Our investigation resulted in the identification of the viral nature of the contaminant. Subsequent experiments indicated that the viral contaminant was a non-enveloped and non-hemadsorbing virus. Transmission electron microscopy (TEM) revealed that the viral contaminant was 25-30 nm in size and morphologically resembled viruses of the family Picornaviridae. The contaminant virus was readily inactivated when exposed to acidic pH, suggesting that the viral contaminant was a member of rhinoviruses. Although incapable of infecting CHO cells, the viral contaminant replicated efficiently in Vero cell with a life cycle of approximately 16 h. Our investigation provided compelling data demonstrating that the viral contaminant did not originate from the MCB. Instead, it was introduced into the process during cell passaging and a possible entry point was proposed. We identified the viral contaminant as an equine rhinitis A virus using molecular cloning and DNA sequencing. Finally, our investigation led us to conclude that the source of the viral contaminant was the equine serum added to the cell growth medium in the 9 CFR bovine virus test.

  5. Evaluation and selection of test methods for assessment of contaminated sediments in the Baltic Sea

    DEFF Research Database (Denmark)

    Lehtonen, Kari; Ahvo, Aino; Berezina, Nadya

    The purpose of the CONTEST project (2014-15) is to test, develop, evaluate and select suitable biological methods to be applied in the quantitative and qualitative assessment of toxicity of anthropogenically contaminated sediments in the Baltic Sea marine region. Here is presented results from...... showed large variability in the sensitivity of the different biotests. Most of the tests applied showed concentration-dependent effects on the test organisms. New experiments will be carried out in 2015. The CONTEST project is funded by the Nordic Council of Ministers and the Finnish Ministry...... a set of pilot experiments, which were performed by the participating laboratories. Chemical analysis of the contaminated harbour sediment chosen as the test matrix confirmed the presence of high concentrations of polycyclic aromatic hydrocarbons, organotins and trace metals, and the sediment...

  6. Decontamination of radioactively contaminated surfaces - Testing of decontamination agents for textiles. 1. ed.

    International Nuclear Information System (INIS)

    1992-01-01

    The present International Standard provides an experimental method for determining the efficiency of the agents for removal radionuclides deposited on textile materials. It applies to testing the detergents which might be used in water solution for cleaning textiles contaminated by radioactive elements. It is applicable for testing the efficiency of detergents for eliminating non-radioactive dirt

  7. Characteristics of radionuclide contamination of different zones of Semipalatinsk Nuclear Test Site ``Opytnoe pole''

    Science.gov (United States)

    Kadyrzhanov, K. K.; Khazhekber, S.; Lukashenko, S. N.; Solodukhin, V. P.; Kazachevskiy, I. V.; Poznyak, V. L.; Knyazev, B. B.; Rofer, Ch.

    2003-01-01

    Data on the spatial distribution of radionuclides (241Am, 239Pu, 137Cs and 152Eu) formed during nuclear explosions of different types near P2 SNTS test site are presented. Radionuclide contamination induced by the explosions varies in the concentrations of individual radionuclides, their proportions and species. Examination of the variations is a crucial task to plan remediation activities as well as those aimed at decrease of radiation risk for population and prevention of repeated contamination. Concentrations of 241Am and 239+240Pu that are the most toxic radionuclides in the area lie in hundred thousands of Bqkg-1. The most contaminated areas are classified by the radionuclide concentration, ratio and form present in soil.

  8. Inward contaminant leakage tests of the S-Tron Corporation emergency escape breathing device.

    Science.gov (United States)

    1992-04-01

    At the request of S-Tron Corporation, to support their contract with the U.S. Navy, performance tests of the Emergency Escape Breathing Device (EEBD) were conducted in the Environmental Physiology Research Section contaminant leakage chamber. Sulfur ...

  9. Model tests for the efficacy of disinfectants on surfaces. IV. Communication: dependence of test results on the amount of contamination and the kind of active substance.

    Science.gov (United States)

    Peters, J; Spicher, G

    1998-12-01

    In the assessment of efficacy of surface disinfectants, many influencing factors have to be taken into account. One essential item is whether the surface to be disinfected is clean or soiled. Among the feasible soilings, the blood is of particular consequences because it ads impediments to many disinfecting agents. This paper shows to what extent the impairment of the efficacy of typical active agents depends on the blood burden of the surfaces. Therefore, test surfaces (varnished plywood) were contaminated with 0.01 to 0.08 ml of coagulating blood per test area (3 cm2). The blood contained cells of Staphylococcus aureus as test germs. The disinfection was effected by immersing the test objects in the disinfecting solution for 5 seconds and mingling the adhering disinfecting solution (about 0.02 ml) with the coagulated blood on the test surface with a glass spatula for about 20 seconds. Subsequently, the test objects remained in a horizontal position at room conditions for 4 hours and then the numbers of surviving test germs were determined. The graphical representation of the results shows that the efficacy curves of formaldehyde and phenol lie very closely together, i.e. their effect is hardly impaired by the different blood burdens of the test areas. The efficacy curves of glutaraldehyde, peracetic acid, chloramine T, and quaternary ammonium compounds lie very far apart from each other. To achieve the same microbicidal effect (log N/N0 = -5) when the contaminating amount is raised from 10 microliters/3 cm2 to 80 microliters/3 cm2, the concentration of chloramine T has to be raised by a factor of 5.4, peracetic acid by a factor of 9, glutaraldehyde by a factor of 24, quaternary ammonium compound even by a factor of 67. Ethanol and sodium hypochlorite showed a divergent behaviour. For ethanol, the efficacy diminution produced by increasing the contamination amount by a factor of 4 can be compensated by raising the concentration from 50% to about 70%. But again and

  10. Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2009-01-01

    1.1 This test method covers a technique for generating data to characterize the kinetics of the release of outgassing products from materials. This technique will determine both the total mass flux evolved by a material when exposed to a vacuum environment and the deposition of this flux on surfaces held at various specified temperatures. 1.2 This test method describes the test apparatus and related operating procedures for evaluating the total mass flux that is evolved from a material being subjected to temperatures that are between 298 and 398 K. Pressures external to the sample effusion cell are less than 7 × 10−3 Pa (5 × 10−5 torr). Deposition rates are measured during material outgassing tests. A test procedure for collecting data and a test method for processing and presenting the collected data are included. 1.3 This test method can be used to produce the data necessary to support mathematical models used for the prediction of molecular contaminant generation, migration, and deposition. 1.4 Al...

  11. Testing of multistep soil washing for radiocesium-contaminated soil containing plant matter

    International Nuclear Information System (INIS)

    Funakawa, Masafumi; Tagawa, Akihiro; Okuda, Nobuyasu

    2012-01-01

    Decontamination work following radiocesium exposure requires a vast reduction in the amount of contaminated soil generated. The current study subjected 4 types of contaminated soil with different properties to multistep soil washing under the same conditions. This study also determined the effectiveness of radiocesium decontamination and the extent to which the amount of contaminated soil was reduced. In addition, the effectiveness of plant matter separation, adsorbent addition, and grinding as part of multistep soil washing was determined using the same contaminated soil. Results of testing indicated that the rate of radiocesium decontamination ranged from 73.6 to 89.2% and the recovery rate ranged from 51.5 to 84.2% for twice-treated soil, regardless of the soil properties or cesium level. Plant matter in soil had a high radiocesium level. However, there was little plant matter in our soil sample. Therefore, plant matter separation had little effect on the improvement in the percentage of radiocesium decontamination of twice-treated soil. Soil surface grinding improved the rate of radiocesium decontamination of twice-treated soil. However, radiocesium in soil tightly bound with minerals in the soil; thus, the addition of an adsorbent also failed to improve the rate of radiocesium decontamination. (author)

  12. In vitro evaluation of microbial contamination of orthodontic brackets as received from the manufacturer using microbiological and molecular tests.

    Science.gov (United States)

    Dos Santos Gerzson, Darlene R; Simon, Daniel; Dos Anjos, Aline Lima; Freitas, Maria Perpétua Mota

    2015-11-01

    To test the null hypothesis that orthodontic brackets as supplied by manufacturers do not have microbial contamination. The sample comprised 140 brackets of four different commercially available brands, used directly from the manufacturer's packaging, divided into 14 groups (n  =  10 brackets each). Of the 140 pieces, 60 were full cases and 80 were replacement brackets. Materials were tested to detect bacterial growth, analyze types of bacteria present (biochemical test), and identify bacteria (molecular test with polymerase chain reaction [PCR]). In two of 12 groups the brackets showed microbial contamination: group 1, Morelli full case brackets, and group 12, Abzil-3M Unitek replacement brackets. Staphylococcus aureus and Staphylococcus epidermidis were the bacteria identified in groups 1 and 12, respectively (suggested by the biochemical test and confirmed by PCR). Brackets of two brands (Morelli and Abzil-3M Unitek) were found to be contaminated by bacteria in the original packages supplied by the manufacturers, which suggests a risk for patient contamination. These data suggest that the manufacturers of these materials should improve the quality control of the packaging used, including sterilization, for the security of patient health.

  13. Testing contamination risk assessment methods for toxic elements from mine waste sites

    Science.gov (United States)

    Abdaal, A.; Jordan, G.; Szilassi, P.; Kiss, J.; Detzky, G.

    2012-04-01

    Major incidents involving mine waste facilities and poor environmental management practices have left a legacy of thousands of contaminated sites like in the historic mining areas in the Carpathian Basin. Associated environmental risks have triggered the development of new EU environmental legislation to prevent and minimize the effects of such incidents. The Mine Waste Directive requires the risk-based inventory of all mine waste sites in Europe by May 2012. In order to address the mining problems a standard risk-based Pre-selection protocol has been developed by the EU Commission. This paper discusses the heavy metal contamination in acid mine drainage (AMD) for risk assessment (RA) along the Source-Pathway-Receptor chain using decision support methods which are intended to aid national and regional organizations in the inventory and assessment of potentially contaminated mine waste sites. Several recognized methods such as the European Environmental Agency (EEA) standard PRAMS model for soil contamination, US EPA-based AIMSS and Irish HMS-IRC models for RA of abandoned sites are reviewed, compared and tested for the mining waste environment. In total 145 ore mine waste sites have been selected for scientific testing using the EU Pre-selection protocol as a case study from Hungary. The proportion of uncertain to certain responses for a site and for the total number of sites may give an insight of specific and overall uncertainty in the data we use. The Pre-selection questions are efficiently linked to a GIS system as database inquiries using digital spatial data to directly generate answers. Key parameters such as distance to the nearest surface and ground water bodies, to settlements and protected areas are calculated and statistically evaluated using STATGRAPHICS® in order to calibrate the RA models. According to our scientific research results, of the 145 sites 11 sites are the most risky having foundation slope >20o, 57 sites are within distance 66 (class VI

  14. Predicted and observed growth of Listeria monocytogenes in seafood challenge tests and in naturally contaminated cold smoked salmon

    DEFF Research Database (Denmark)

    Dalgaard, Paw; Jørgensen, Lasse Vigel

    1998-01-01

    with various types of seafoods. Storage trials clearly showed the growth of L. monocytogenes in naturally contaminated cold-smoked salmon to be markedly slower than growth in inoculated challenge tests. Consequently, all four models substantially overestimated growth in the naturally contaminated products...

  15. Lifetime prediction and reliability estimation methodology for Stirling-type pulse tube refrigerators by gaseous contamination accelerated degradation testing

    Science.gov (United States)

    Wan, Fubin; Tan, Yuanyuan; Jiang, Zhenhua; Chen, Xun; Wu, Yinong; Zhao, Peng

    2017-12-01

    Lifetime and reliability are the two performance parameters of premium importance for modern space Stirling-type pulse tube refrigerators (SPTRs), which are required to operate in excess of 10 years. Demonstration of these parameters provides a significant challenge. This paper proposes a lifetime prediction and reliability estimation method that utilizes accelerated degradation testing (ADT) for SPTRs related to gaseous contamination failure. The method was experimentally validated via three groups of gaseous contamination ADT. First, the performance degradation model based on mechanism of contamination failure and material outgassing characteristics of SPTRs was established. Next, a preliminary test was performed to determine whether the mechanism of contamination failure of the SPTRs during ADT is consistent with normal life testing. Subsequently, the experimental program of ADT was designed for SPTRs. Then, three groups of gaseous contamination ADT were performed at elevated ambient temperatures of 40 °C, 50 °C, and 60 °C, respectively and the estimated lifetimes of the SPTRs under normal condition were obtained through acceleration model (Arrhenius model). The results show good fitting of the degradation model with the experimental data. Finally, we obtained the reliability estimation of SPTRs through using the Weibull distribution. The proposed novel methodology enables us to take less than one year time to estimate the reliability of the SPTRs designed for more than 10 years.

  16. Avoidance tests with Folsomia candida for the assessment of copper contamination in agricultural soils

    International Nuclear Information System (INIS)

    Boiteau, G.; Lynch, D.H.; MacKinley, P.

    2011-01-01

    The feasibility of assessing copper accumulation in agricultural soils using avoidance tests with a Canadian strain of Folsomia candida was investigated under laboratory conditions. The avoidance response to nominal copper sulfate concentrations of 0, 200, 800, 1600 and 3200 mg kg -1 in OECD soil was inconsistent between trials with the standard plastic cup or a modified Petri dish method requiring less soil. However, combined results from three Petri dish trials decreased variability and provided a 75% avoidance level, close to the 80% criterion proposed for avoidance tests. A Copper avoidance EC 50s of 18 mg kg -1 was obtained using the Petri dish method whether tests were conducted with or without light. While Petri dish tests have potential as a cheap tool to distinguish metal contaminated soils from uncontaminated soils they would be unsuitable for tracking or quantifying changes in metal concentrations. throughout remediation. Advantages and limitations of the method have been presented. - Research highlights: → Avoidance cup test using Folsomia candida detects Cu independently of concentration. → Improved avoidance Petri dish test detects Cu in soil in function of concentration. → Cu voidance tests had similar EC50 values whether conducted with or without light. → Combining Cu avoidance test trials in OECD soil reduced the variability of results. - Improved avoidance tests having an EC 50 value similar to the background Cu concentration in uncontaminated agricultural soils can distinguish Cu contaminated and Cu free OECD soil.

  17. [The dose estimation to the population as a result of radioactive contamination of the Semipalatinsk Test area].

    Science.gov (United States)

    Spiridonova, S I; Mukusheva, M K; Shubina, O A; Solomatin, V M; Epifanova, I E

    2008-01-01

    The results are presented from estimation of spatial distribution of 137Cs and 90Sr contamination densities in the areas of horses and sheep grazing within the Semipalatinsk Test Site. Dose burdens to various cohorts of the population living within the STS and consuming contaminated animal products are predicted. Doses of shepherds in the most contaminated pasture areas have been found to exceed the accepted limit (1 mSv/y). The conclusion is made about the need for further studies on the risk assessment of the STS population exposure above the accepted limits.

  18. Contamination and UV ageing of diffuser targets used in satellite inflight and ground reference test site calibrations

    Science.gov (United States)

    Vaskuri, Anna; Greenwell, Claire; Hessey, Isabel; Tompkins, Jordan; Woolliams, Emma

    2018-02-01

    Diffuser reflectance targets are key components in in-orbit calibrations and for verifying ground reference test sites. In this work, Spectralon, Diffusil, and Heraeus diffusers were exposed to exhaust gases and ultraviolet (UV) radiation in the ambient air conditions and their degradations were monitored by measuring changes in spectral reflectances. Spectralon is a state-of-the-art diffuser made of polytetrafluoroethylene, and Diffusil and Heraeus diffusers are made of fused silica with gas bubbles inside. Based on the contamination tests, Spectralon degrades faster than fused silica diffusers. For the samples exposed to contamination for 20 minutes, the 250 nm - 400 nm total diffuse spectral reflectance of Spectralon degraded 3-5 times more when exposed to petrol-like emission and 16-23 times more when exposed to diesel-like emission, compared with Diffusil. When the reflectance changes of Spectralon were compared with those of Heraeus, Spectralon degraded 3-4 times more when exposed to petrol-like emission for 20 minutes and 5-7 times more when exposed to diesel-like emission for 7.5 minutes. When the samples contaminated were exposed to UV radiation in the ambient air, their reflectance gradually restored back to the original level. In conclusion, fused silica diffusers are more resistant to hydrocarbon contaminants present in ground reference test sites, and thus more stable under UV radiation in the air.

  19. Mechanisms for surface contamination of soils and bottom sediments in the Shagan River zone within former Semipalatinsk Nuclear Test Site.

    Science.gov (United States)

    Aidarkhanov, A O; Lukashenko, S N; Lyakhova, O N; Subbotin, S B; Yakovenko, Yu Yu; Genova, S V; Aidarkhanova, A K

    2013-10-01

    The Shagan River is the only surface watercourse within the former Semipalatinsk Test Site (STS). Research in the valley of the Shagan River was carried out to study the possible migration of artificial radionuclides with surface waters over considerable distances, with the possibility these radionuclides may have entered the Irtysh River. The investigations revealed that radioactive contamination of soil was primarily caused by the first underground nuclear test with soil outburst conducted at the "Balapan" site in Borehole 1004. The surface nuclear tests carried out at the "Experimental Field" site and global fallout made insignificant contributions to contamination. The most polluted is the area in the immediate vicinity of the "Atomic" Lake crater. Contamination at the site is spatial. The total area of contamination is limited to 10-12 km from the crater piles. The ratio of plutonium isotopes was useful to determine the source of soil contamination. There was virtual absence of artificial radionuclide migration with surface waters, and possible cross-border transfer of radionuclides with the waters of Shagan and Irtysh rivers was not confirmed. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Test plan guidance for transuranic-contaminated arid landfill remedial technology development

    International Nuclear Information System (INIS)

    Evans, J.; Shaw, P.

    1995-05-01

    This document provides guidance for preparing plans to test or demonstrate buried waste assessment or remediation technologies supported by the U.S. Department of Energy's Landfill Stabilization Focus Area, Transuranic-Contaminated Arid Landfill Product Line. This document also provides guidance for development of data quality objectives, along with the necessary data to meet the project objectives. The purpose is to ensure that useful data of known quality are collected to support conclusions associated with the designated demonstration or test. A properly prepared test plan will integrate specific and appropriate objectives with needed measurements to ensure data will reflect the Department of Energy Office of Technology Development's mission, be consistent with Landfill Stabilization Focus Area test goals, and be useful for the Department of Energy Environmental Restoration and Waste Management programs and other potential partners (e.g., commercial concerns). The test plan becomes the planning and working document for the demonstration or test to be conducted ensuring procedures are followed that will allow data of sufficient quality to be collected for comparison and evaluation

  1. Sandia technology engineering and science accomplishments

    Energy Technology Data Exchange (ETDEWEB)

    1993-03-01

    Sandia is a DOE multiprogram engineering and science laboratory with major facilities at Albuquerque, New Mexico, and Livermore, California, and a test range near Tonapah, Nevada. We have major research and development responsibilities for nuclear weapons, arms control, energy, the environment, economic competitiveness, and other areas of importance to the needs of the nation. Our principal mission is to support national defense policies by ensuring that the nuclear weapon stockpile meets the highest standards of safety, reliability, security, use control, and military performance. Selected unclassified technical activities and accomplishments are reported here. Topics include advanced manufacturing technologies, intelligent machines, computational simulation, sensors and instrumentation, information management, energy and environment, and weapons technology.

  2. The influence of Triga 2000 reactor operation on the surface contamination at reactor room using smear test method

    International Nuclear Information System (INIS)

    Bintu Khoiriyyah; Budi Purnama; Tri Cahyo Laksono

    2016-01-01

    The monitoring of surface contamination should be conducted to determine the safety of work areas. Surface contamination at the TRIGA 2000 reactor room which is on PSTNT-BATAN Bandung remain to be implemented although reactor not operating. In this research monitoring of surface contamination when TRIGA 2000 in operation of the first time after several years not operating aims to determine the influence on the results of monitoring. The monitoring of surface contamination has been done using smear test method at some predetermined in TRIGA 2000 reactor room. The highest surface contamination activities is obtained 0.32 Bq/cm 2 and there are some points that are not detected. Based on keputusan kepala BAPETEN No.1/Ka BAPETEN/ V/99 the work showed that the TRIGA 2000 reactor in the category of low area contamination, that is <3.7 Bq/cm 2 to gross beta. (author)

  3. Corrective Action Investigation Plan for Corrective Action Unit 528: Polychlorinated Biphenyls Contamination, Nevada Test Site, Nevada, Rev. 0

    Energy Technology Data Exchange (ETDEWEB)

    U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office

    2003-05-08

    This Corrective Action Investigation Plan contains the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office's approach to collect the data necessary to evaluate corrective action alternatives appropriate for the closure of Corrective Action Unit (CAU) 528, Polychlorinated Biphenyls Contamination (PCBs), Nevada Test Site (NTS), Nevada, under the Federal Facility Agreement and Consent Order. Located in the southwestern portion of Area 25 on the NTS in Jackass Flats (adjacent to Test Cell C [TCC]), CAU 528 consists of Corrective Action Site 25-27-03, Polychlorinated Biphenyls Surface Contamination. Test Cell C was built to support the Nuclear Rocket Development Station (operational between 1959 and 1973) activities including conducting ground tests and static firings of nuclear engine reactors. Although CAU 528 was not considered as a direct potential source of PCBs and petroleum contamination, two potential sources of contamination have nevertheless been identified from an unknown source in concentrations that could potentially pose an unacceptable risk to human health and/or the environment. This CAU's close proximity to TCC prompted Shaw to collect surface soil samples, which have indicated the presence of PCBs extending throughout the area to the north, east, south, and even to the edge of the western boundary. Based on this information, more extensive field investigation activities are being planned, the results of which are to be used to support a defensible evaluation of corrective action alternatives in the corrective action decision document.

  4. Test plan for the soils facility demonstration: A petroleum contaminated soil bioremediation facility

    International Nuclear Information System (INIS)

    Lombard, K.H.

    1994-01-01

    The objectives of this test plan are to show the value added by using bioremediation as an effective and environmentally sound method to remediate petroleum contaminated soils (PCS) by: demonstrating bioremediation as a permanent method for remediating soils contaminated with petroleum products; establishing the best operating conditions for maximizing bioremediation and minimizing volatilization for SRS PCS during different seasons; determining the minimum set of analyses and sampling frequency to allow efficient and cost-effective operation; determining best use of existing site equipment and personnel to optimize facility operations and conserve SRS resources; and as an ancillary objective, demonstrating and optimizing new and innovative analytical techniques that will lower cost, decrease time, and decrease secondary waste streams for required PCS assays

  5. Toxicity assessment of industrial chemicals and airborne contaminants: transition from in vivo to in vitro test methods: a review.

    Science.gov (United States)

    Bakand, S; Winder, C; Khalil, C; Hayes, A

    2005-12-01

    Exposure to occupational and environmental contaminants is a major contributor to human health problems. Inhalation of gases, vapors, aerosols, and mixtures of these can cause a wide range of adverse health effects, ranging from simple irritation to systemic diseases. Despite significant achievements in the risk assessment of chemicals, the toxicological database, particularly for industrial chemicals, remains limited. Considering there are approximately 80,000 chemicals in commerce, and an extremely large number of chemical mixtures, in vivo testing of this large number is unachievable from both economical and practical perspectives. While in vitro methods are capable of rapidly providing toxicity information, regulatory agencies in general are still cautious about the replacement of whole-animal methods with new in vitro techniques. Although studying the toxic effects of inhaled chemicals is a complex subject, recent studies demonstrate that in vitro methods may have significant potential for assessing the toxicity of airborne contaminants. In this review, current toxicity test methods for risk evaluation of industrial chemicals and airborne contaminants are presented. To evaluate the potential applications of in vitro methods for studying respiratory toxicity, more recent models developed for toxicity testing of airborne contaminants are discussed.

  6. Vitrification testing of soil fines from contaminated Hanford 100 Area and 300 Area soils

    International Nuclear Information System (INIS)

    Ludowise, J.D.

    1994-01-01

    The suitability of Hanford soil for vitrification is well known and has been demonstrated extensively in other work. The tests reported here were carried out to confirm the applicability of vitrification to the soil fines (a subset of the Hanford soil potentially different in composition from the bulk soil) and to provide data on the performance of actual, vitrified soil fines. It was determined that the soil fines were generally similar in composition to the bulk Hanford soil, although the fraction 2 O. The vitrified waste (plus additives) occupies only 60% of the volume of the initial untreated waste. Leach testing has shown the glasses made from the soil fines to be very durable relative to natural and man-made glasses and has demonstrated the ability of the vitrified waste to greatly reduce the release of radionuclides to the environment. Viscosity and electrical conductivity measurements indicate that the soil fines will be readily processable, although with levels of additives slightly greater than used in the radioactive melts. These tests demonstrate the applicability of vitrification to the contaminated soil fines and the exceptional performance of the waste form resulting from the vitrification of contaminated Hanford soils

  7. Assessment of radioactive contaminations of the ground in Hanover-List with scales and methods of the German Federal Ordinance on Soil Protection and Contaminated Sites (BBodSchV). Pt. 1. Derivation of test thresholds

    International Nuclear Information System (INIS)

    Gellermann, Rainer; Guenther, Petra; Evers, Burkhard

    2010-01-01

    Background, aim, and scope: In the district List of Hanover (Lower Saxony) radioactive contaminations of the ground were detected at a site of a former chemical plant. Due to the lack of an ordinance regarding intervention regulations in the case of radioactive contaminations in Germany this situation had to be assessed on the basis of scales and methods of the German regulations concerning soil protection and contaminated sites. In particular it was necessary to develop methods and levels for the assessment of radioactive contaminations. Materials and methods: Because radioactivity can be considered as a carcinogenic substance the methodical approaches of the BBodSchV for this group of substances were used in order to derive test thresholds for radioactive contaminations at children's play areas, residential areas as well as parks and recreation facilities. Results: For the assessment of radioactive soil contaminations with naturally occurring radionuclides at children's play areas and residential areas the ingestion of soil is the decisive pathway of exposure. For children's play areas a threshold level of 0.2 Bq/g for the sum U-238,max + Th-232,max was obtained. At areas with only impacts of ambient radiation from the contaminated ground test thresholds of 0.5 μSv/h are recommended. A special pathway is the migration of radon from the contaminated soil into basement floors of buildings. Taking into account the natural background levels of radon a concentration of 260 Bq/m 3 is suggested as a test threshold in the framework of soil protection benchmarks. Discussion and conclusions will be described in Part 2 of the paper.

  8. Field test of plutonium and thorium contaminated clay soils from the Mound Site using the ACT*DE*CON Process

    International Nuclear Information System (INIS)

    Johnson, J.O.; Swift, N.A.; Church, R.H.; Neff, R.A.

    1998-01-01

    A treatability test was run during the summer and fall of 1997 to demonstrate the effectiveness of ACT*DE*CON for removing plutonium and thorium from the clay soils around Mound. ACT*DE*CON is a proprietary solution patented by Selentec. The process utilized a highly selective dissolution of the contaminants by the use of a chemical wash. The pilot scale process involved pretreatment of the soil in an attrition scrubber with ACT*DE*CON solution. This blended solution was then passed through a counter-current extraction chamber where additional contact with ACT*DE*CON solution occurred, followed by a rinse cycle. During this process sand was added to aid contact of the solution with the soil particles. The sand is removed during the rinse step and reused. The chelating agent is separated from the contaminant and recycled back into the process, along with the reverse osmosis permeate. The resulting solution can be further treated to concentrate the contaminant. Three different types of environmental soils were tested -- plutonium and thorium contaminated soils with the natural clay content, and plutonium contaminated soils with a high percentage of fine clay particles. The goal of these tests was to reduce the plutonium levels from several hundreds of pCi/g to between 25 and 75 pCi/g and the thorium from a couple hundred pCi/g to less than 5 pCi/g. The results of these four tests are presented along with a discussion of the operating parameters and the lessons learned relating to full scale implementation at Mound as well as other potential applications of this process

  9. Test of active coal capacity for retaining gaseous effluents contaminated by 131 I

    International Nuclear Information System (INIS)

    Campeanu, Catalina; Cruceru, Madalina; Neacsu, Elena

    1999-01-01

    The aim of this paper is to test the retaining capacity of the active coal of the filters for gaseous effluents contaminated by 131 I. The active coal filters are design for equipping ventilation installations of nuclear plants in which radioactive iodine and combination of it were produced and handled. Such active coal filters are provided also to sorbonnes for radiochemical and physical handling of radioactive iodine. Testing the retaining capacity of active coal for filters is an obvious step, particularly, when the material was stored long time after preparation

  10. Assisted bioremediation tests on three natural soils contaminated with benzene

    OpenAIRE

    Carvalho, Maria Manuela; Vila, Maria Cristina; Matos, Cristina Delerue; Teles, Maria Teresa Oliva; Fiúza, António

    2015-01-01

    Bioremediation is an attractive and useful method of remediation of soils contaminated with petroleum hydrocarbons because it is simple to maintain, applicable in large areas, is economic and enables an effective destruction of the contaminant. Usually, the autochthone microorganisms have no ability to degrade these compounds, and otherwise, the contaminated sites have inappropriate environmental conditions for microorganism’s development. These problems can be overcome by assisted bioremedia...

  11. Airborne mapping of radioactive contamination. Results from a test in Finland, RESUME95

    Energy Technology Data Exchange (ETDEWEB)

    Roenning, S.; Smethurst, M.A. [Geological Survey of Norway (Norway)

    1997-12-31

    The Geological Survey of Norway participated in the exercise RESUME95 (Rapid Environmental Surveying Using Mobile Equipment 95) in Finland, during August 1995. The purpose of the exercise was to 1) test preparedness in the Nordic countries for accidents involving the release and dispersal of radioactive material, 2) compare results from the different teams participating in the exercise, 3) establish routines for the exchange of data and 4) investigate the possibility of international assistance in the event of nuclear accidents. The Geological Survey of Norway carried out a survey over three test areas (area I, II and III). All three areas were contaminated with man made radionuclides in the days following the Chernobyl nuclear reactor accident. The Cesium-137 contamination level was reported to be about 50 kBq/m{sup 2} in area I, and this area was used for calibration. In area II mapping of Cesium-137 ground concentration was carried out. Detection of hidden artificial radiation sources were the main purpose in area III. This report describes the exercise - RESUME95, field operations, calibration, mapping of Cesium-137 ground concentration and detection of hidden point sources. Results are presented as colour maps. (au).

  12. Airborne mapping of radioactive contamination. Results from a test in Finland, RESUME95

    Energy Technology Data Exchange (ETDEWEB)

    Roenning, S; Smethurst, M A [Geological Survey of Norway (Norway)

    1998-12-31

    The Geological Survey of Norway participated in the exercise RESUME95 (Rapid Environmental Surveying Using Mobile Equipment 95) in Finland, during August 1995. The purpose of the exercise was to 1) test preparedness in the Nordic countries for accidents involving the release and dispersal of radioactive material, 2) compare results from the different teams participating in the exercise, 3) establish routines for the exchange of data and 4) investigate the possibility of international assistance in the event of nuclear accidents. The Geological Survey of Norway carried out a survey over three test areas (area I, II and III). All three areas were contaminated with man made radionuclides in the days following the Chernobyl nuclear reactor accident. The Cesium-137 contamination level was reported to be about 50 kBq/m{sup 2} in area I, and this area was used for calibration. In area II mapping of Cesium-137 ground concentration was carried out. Detection of hidden artificial radiation sources were the main purpose in area III. This report describes the exercise - RESUME95, field operations, calibration, mapping of Cesium-137 ground concentration and detection of hidden point sources. Results are presented as colour maps. (au).

  13. Variability of sediment-contact tests in freshwater sediments with low-level anthropogenic contamination - Determination of toxicity thresholds

    International Nuclear Information System (INIS)

    Hoess, S.; Ahlf, W.; Fahnenstich, C.; Gilberg, D.; Hollert, H.; Melbye, K.; Meller, M.; Hammers-Wirtz, M.; Heininger, P.; Neumann-Hensel, H.; Ottermanns, R.; Ratte, H.-T.

    2010-01-01

    Freshwater sediments with low levels of anthropogenic contamination and a broad range of geochemical properties were investigated using various sediment-contact tests in order to study the natural variability and to define toxicity thresholds for the various toxicity endpoints. Tests were performed with bacteria (Arthrobacter globiformis), yeast (Saccharomyces cerevisiae), nematodes (Caenorhabditis elegans), oligochaetes (Lumbriculus variegatus), higher plants (Myriophyllum aquaticum), and the eggs of zebrafish (Danio rerio). The variability in the response of some of the contact tests could be explained by particle size distribution and organic content. Only for two native sediments could a pollution effect not be excluded. Based on the minimal detectable difference (MDD) and the maximal tolerable inhibition (MTI), toxicity thresholds (% inhibition compared to the control) were derived for each toxicity parameter: >20% for plant growth and fish-egg survival, >25% for nematode growth and oligochaete reproduction, >50% for nematode reproduction and >60% for bacterial enzyme activity. - Sediment-contact tests require toxicity thresholds based on their variability in native sediments with low-level contamination.

  14. Variability of sediment-contact tests in freshwater sediments with low-level anthropogenic contamination - Determination of toxicity thresholds

    Energy Technology Data Exchange (ETDEWEB)

    Hoess, S., E-mail: hoess@ecossa.d [Ecossa, Giselastr. 6, 82319 Starnberg (Germany); Institute of Biodiversity - Network (IBN), Dreikronengasse 2, 93047 Regensburg (Germany); Ahlf, W., E-mail: ahlf@tu-harburg.d [Institute of Environmental Technology and Energy Economics, Technical University Hamburg-Harburg, Eissendorfer Str. 40, 21071 Hamburg (Germany); Fahnenstich, C. [Institute of Environmental Technology and Energy Economics, Technical University Hamburg-Harburg, Eissendorfer Str. 40, 21071 Hamburg (Germany); Gilberg, D., E-mail: d-gilberg@ect.d [ECT Oekotoxikologie, Boettgerstr. 2-14, 65439 Floersheim (Germany); Hollert, H., E-mail: henner.hollert@bio5.rwth-aachen.d [Department of Ecosystem Analysis, Institute for Environmental Research (Biology 5), RWTH Aachen University, Worringerweg 1, 52074 Aachen (Germany); Melbye, K. [Dr. Fintelmann and Dr. Meyer, Mendelssohnstr. 15D, 22761 Hamburg (Germany); Meller, M., E-mail: m-meller@ecotox-consult.d [ECT Oekotoxikologie, Boettgerstr. 2-14, 65439 Floersheim (Germany); Hammers-Wirtz, M., E-mail: hammers-wirtz@gaiac.rwth-aachen.d [Research Institute for Ecosystem Analysis and Assessment (gaiac), RWTH Aachen University, Worringerweg 1, 52056 Aachen (Germany); Heininger, P., E-mail: heininger@bafg.d [Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56070 Koblenz (Germany); Neumann-Hensel, H., E-mail: hensel@fintelmann-meyer.d [Dr. Fintelmann and Dr. Meyer, Mendelssohnstr. 15D, 22761 Hamburg (Germany); Ottermanns, R., E-mail: ottermanns@bio5.rwth-aachen.d [Chair for Environmental Biology and Chemodynamics, Institute for Environmental Research (Biology 5), RWTH Aachen University, Worringerweg 1, 52074 Aachen (Germany); Ratte, H.-T., E-mail: toni.ratte@bio5.rwth-aachen.d [Chair for Environmental Biology and Chemodynamics, Institute for Environmental Research (Biology 5), RWTH Aachen University, Worringerweg 1, 52074 Aachen (Germany)

    2010-09-15

    Freshwater sediments with low levels of anthropogenic contamination and a broad range of geochemical properties were investigated using various sediment-contact tests in order to study the natural variability and to define toxicity thresholds for the various toxicity endpoints. Tests were performed with bacteria (Arthrobacter globiformis), yeast (Saccharomyces cerevisiae), nematodes (Caenorhabditis elegans), oligochaetes (Lumbriculus variegatus), higher plants (Myriophyllum aquaticum), and the eggs of zebrafish (Danio rerio). The variability in the response of some of the contact tests could be explained by particle size distribution and organic content. Only for two native sediments could a pollution effect not be excluded. Based on the minimal detectable difference (MDD) and the maximal tolerable inhibition (MTI), toxicity thresholds (% inhibition compared to the control) were derived for each toxicity parameter: >20% for plant growth and fish-egg survival, >25% for nematode growth and oligochaete reproduction, >50% for nematode reproduction and >60% for bacterial enzyme activity. - Sediment-contact tests require toxicity thresholds based on their variability in native sediments with low-level contamination.

  15. Successful field tests of a multi-process phytoremediation system for decontamination of persistent petroleum and organic contaminants

    Energy Technology Data Exchange (ETDEWEB)

    Greenberg, B.M.; Huang, X.D.; Gurska, Y.; Gerhardt, K.E.; Wang, W.; Lampi, M.A.; Zhang, C.; Khalid, A.; Isherwood, D.; Chang, P.; Wang, H.; Dixon, D.G.; Glick, B.R. [Waterloo Univ., ON (Canada)

    2006-07-01

    A large number of aquatic and terrestrial environments are polluted with various levels of toxicants. Metals, organics and total petroleum hydrocarbons from anthropogenic sources pose a risk to both human health and the health of ecosystems. Although these persistent contaminants are difficult to remediate, several industrial sites throughout North America are being remediated as part of land reclamation and restoration programs. This paper addressed the issue of phytoremediation for removing contaminants from soils. Phytoremediation is considered to be a viable remediation strategy because the increased biomass of plants, relative to the biomass of soil microbes in the absence of plants, allows for higher throughput. Extensive root systems can infiltrate large volumes of soil, thus promoting degradation of contaminants over a wide area. This paper described a newly developed multi-process phytoremediation system with accelerated remediation kinetics to effectively remove polycyclic aromatic hydrocarbons (PAH), total petroleum hydrocarbons (TPH) and chlorinated hydrocarbons (CHC) from soils. The system combines land farming/sunlight exposure; inoculation of contaminant degrading bacteria; and, plant growth with plant growth promoting rhizobacteria which mitigates the effects of stress ethylene in plants. The primary factor for success was the interaction between the plant and the plant growth promoting rhizobacteria. Several field tests were conducted following successful greenhouse tests. Results at a TPH contaminated site in Sarnia, Ontario showed that over a 2 year period, 60 to 70 per cent remediation of 15 per cent TPH was achieved. At a site in Turner Valley, Alberta, 35 per cent remediation of 1 per cent recalcitrant TPH was achieved, while a DDT contaminated site near Simcoe, Ontario had nearly 30 per cent of CHC removed in a 3 month period. 34 refs., 2 tabs., 2 figs.

  16. Successful field tests of a multi-process phytoremediation system for decontamination of persistent petroleum and organic contaminants

    International Nuclear Information System (INIS)

    Greenberg, B.M.; Huang, X.D.; Gurska, Y.; Gerhardt, K.E.; Wang, W.; Lampi, M.A.; Zhang, C.; Khalid, A.; Isherwood, D.; Chang, P.; Wang, H.; Dixon, D.G.; Glick, B.R.

    2006-01-01

    A large number of aquatic and terrestrial environments are polluted with various levels of toxicants. Metals, organics and total petroleum hydrocarbons from anthropogenic sources pose a risk to both human health and the health of ecosystems. Although these persistent contaminants are difficult to remediate, several industrial sites throughout North America are being remediated as part of land reclamation and restoration programs. This paper addressed the issue of phytoremediation for removing contaminants from soils. Phytoremediation is considered to be a viable remediation strategy because the increased biomass of plants, relative to the biomass of soil microbes in the absence of plants, allows for higher throughput. Extensive root systems can infiltrate large volumes of soil, thus promoting degradation of contaminants over a wide area. This paper described a newly developed multi-process phytoremediation system with accelerated remediation kinetics to effectively remove polycyclic aromatic hydrocarbons (PAH), total petroleum hydrocarbons (TPH) and chlorinated hydrocarbons (CHC) from soils. The system combines land farming/sunlight exposure; inoculation of contaminant degrading bacteria; and, plant growth with plant growth promoting rhizobacteria which mitigates the effects of stress ethylene in plants. The primary factor for success was the interaction between the plant and the plant growth promoting rhizobacteria. Several field tests were conducted following successful greenhouse tests. Results at a TPH contaminated site in Sarnia, Ontario showed that over a 2 year period, 60 to 70 per cent remediation of 15 per cent TPH was achieved. At a site in Turner Valley, Alberta, 35 per cent remediation of 1 per cent recalcitrant TPH was achieved, while a DDT contaminated site near Simcoe, Ontario had nearly 30 per cent of CHC removed in a 3 month period. 34 refs., 2 tabs., 2 figs

  17. Contamination Control for Thermal Engineers

    Science.gov (United States)

    Rivera, Rachel B.

    2015-01-01

    The presentation will be given at the 26th Annual Thermal Fluids Analysis Workshop (TFAWS 2015) hosted by the Goddard Spaceflight Center (GSFC) Thermal Engineering Branch (Code 545). This course will cover the basics of Contamination Control, including contamination control related failures, the effects of contamination on Flight Hardware, what contamination requirements translate to, design methodology, and implementing contamination control into Integration, Testing and Launch.

  18. Development of treatment technology of radio-contaminated coolant in fuel test loop

    International Nuclear Information System (INIS)

    Kim, J. Y.

    1997-10-01

    In 1995, the installation of KMRR located in KAERI provided a milestone in independence of nuclear technologies in Korea. The independence of technologies is only possible through the enormous investment for research and through the active approaches for various experiments. The performance of various experiments enhanced the risk of environmental pollution and the nuclear fuel irradiation test is one of those experiments. The damage of fuel which might happen any time in irradiation test, will discharge high level radioactive materials from the inside of failed fuel and will gradually contaminate the cooling water in near vicinity. Accordingly, the proper management of coolant having high temperature and high level . (author). refs., tabs., figs

  19. Development of treatment technology of radio-contaminated coolant in fuel test loop

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. Y.

    1997-10-01

    In 1995, the installation of KMRR located in KAERI provided a milestone in independence of nuclear technologies in Korea. The independence of technologies is only possible through the enormous investment for research and through the active approaches for various experiments. The performance of various experiments enhanced the risk of environmental pollution and the nuclear fuel irradiation test is one of those experiments. The damage of fuel which might happen any time in irradiation test, will discharge high level radioactive materials from the inside of failed fuel and will gradually contaminate the cooling water in near vicinity. Accordingly, the proper management of coolant having high temperature and high level . (author). refs., tabs., figs.

  20. Summary of data concerning radiological contamination at well PM-2, Nevada Test Site, Nye County, Nevada

    International Nuclear Information System (INIS)

    Russell, G.M.; Locke, G.L.

    1997-01-01

    Analysis of water from well Pahute Mesa No. 2 (PM-2), on Pahute Mesa in the extreme northwestern part of the Nevada Test Site, indicated tritium concentrations above background levels in August 1993. A coordinated investigation of the tritium occurrence in well PM-2 was undertaken by the Hydrologic Resources Management Program of the US Department of Energy. Geologic and hydrologic properties of the hydrogeologic units were characterized using existing information. Soil around the well and water quality in the well were characterized during the investigation. The purpose of this report is to present existing information and results from a coordinated investigation of tritium occurrence. The objectives of the overall investigation include: (1) determination of the type and concentration of contamination; (2) identification of the source and mechanism of contamination; (3) estimation of the extent of radiological contamination; (4) initiation of appropriate monitoring of the contamination; and (5) reporting of investigation results. Compiled and tabulated data of the area are presented. The report also includes characterization of geology, soil, hydrology, and water quality data

  1. A test to illustrate the effects of BioSolve on the mobility of contaminated soils

    International Nuclear Information System (INIS)

    Jackson, Lorri M.

    1999-01-01

    Mountain States BioSolve manufactures products for in-situ bioremediation projects. One of their products, BioSolve, desorbs and emulsifies hydrocarbons in a contaminated substrate. BioSolve is a blend of water-based, biodegradable surfactants which were engineered as a clean-up and mitigation agent for hydrocarbon products. Its basic mechanism is to emulsify the hydrocarbon into small encapsulated particles in a water/oxygen-bearing solution, desorbing hydrocarbon molecules from soil particles. This allows bacteria to more effectively metabolize the contaminate. During desorption, Total Petroleum Hydrocarbons (TPH) levels may increase shortly after application due to the removal of contaminate from soil particles which increases the total recoverable hydrocarbon. This allows the hydrocarbon, in the pump and treat process, to become mobile, and thus carried with the water to the recovery wells where it can be removed. This testing does not address pump and treat technology but only the increased surface area for bioremediation enhancement

  2. Testing of TSCA incinerator for destruction of PCBs in uranium-contaminated wastes

    International Nuclear Information System (INIS)

    Anderson, R.W.

    1988-01-01

    A Toxic Substances Control Act (TSCA) incinerator for environmentally safe destruction of PCBs and hazardous organic materials contaminated with low-level radioactive wastes from seven DOE facilities has been constructed at the Oak Ridge Gaseous Diffusion Plant, and has undergone performance testing with PCB surrogates. The system incorporates state-of-the-art off-gas treatment, a highly instrumented kiln and secondary combustion chamber, and an inert-atmosphere solids-handling feed system. Release of organic during an upset event, which triggers opening of the secondary combustion-chamber relief vent, will be prevented by maintaining excess oxygen in the kiln and a high temperature in the secondary combustion chamber with an operating burner. Mixtures of chlorinated benzenes used in performance testing to simulate destruction of PCB, worst-case studies to satisfy regulatory concerns, and implications of performance test results are discussed. 4 references

  3. Testing Single and Combinations of Amendments for Stabilization of Metals in Contrasting Extremely Contaminated Soils

    Directory of Open Access Journals (Sweden)

    Siebielec G.

    2013-04-01

    Full Text Available Metals can be stabilized by soil amendments that increase metals adsorption or alter their chemical forms. Such treatments may limit the risk related to the contamination through reduction of metal transfer to the food chain (reduction of metal uptake by plants and its availability to soil organisms and metals migration within the environment. There is a need for experiments comparing various soil amendments available at reasonable amounts under similar environmental conditions. The other question is whether all components of soil environment or soil functions are similarly protected after remediation treatment. We conducted a series of pot studies to test some traditional and novel amendments and their combinations. The treatments were tested for several highly Zn/Cd/Pb contaminated soils. Among traditional amendments composts were the most effective – they ensured plant growth, increased soil microbial activity, reduced Cd in earthworms, reduced Pb bioaccessibility and increased share of unavailable forms of Cd and Pb.

  4. Forensic Luminol Blood Test for Preventing Cross-contamination in Dentistry: An Evaluation of a Dental School Clinic.

    Science.gov (United States)

    Bortoluzzi, Marcelo Carlos; Cadore, Peterson; Gallon, Andrea; Imanishi, Soraia Almeida Watanabe

    2014-10-01

    More than 200 different diseases may be transmitted from exposure to blood in the dental setting. The aim of this study is to identify possible faults in the crosscontamination chain control in a dental school clinic searching for traces of blood in the clinical contact surfaces (CCS) through forensic luminol blood test. Traces of invisible blood where randomly searched in CCS of one dental school clinic. Forty eight surfaces areas in the CCS were tested and the presence of invisible and remnant blood was identified in 28 (58.3%) items. We suggest that the luminol method is suitable for identifying contamination with invisible blood traces and this method may be a useful tool to prevent cross-contamination in the dental care setting.

  5. SUPERFUND TREATABILITY CLEARINGHOUSE: INCINERATION TEST OF EXPLOSIVES CONTAMINATED SOILS AT SAVANNA ARMY DEPOT ACTIVITY, SAVANNA, ILLINOIS

    Science.gov (United States)

    The primary objective of these tests was to demonstrate the effectiveness of incineration as a decontamination method for explosives contaminated sails. A pilot-scale rotary kiln incinerator, manufactured by ThermAll, Inc., was used to treat both sandy and clayey...

  6. Radioactive contamination of soil-vegetation cover in some southern areas of Semipalatinsk test site

    International Nuclear Information System (INIS)

    Tuleubaev, B.A.; Zharikov, S.K.

    2001-01-01

    The nature of radioactive contamination of meadow-pasture lands in the south of the Semipalatinsk test site (STS) has been studied using experimental data. Individual parameters of radionuclide transport from soil into plants depending upon soil type and sub-type, extent of land use for hay-making and pasturing, and other nature-climatic and anthropogenic factors have been determined. (author)

  7. Decontamination of radioactively contaminated surfaces - Method for testing and assessing the ease of decontamination (International Standard Publication ISO 8690:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    The specifications laid down in this International Standard apply to the testing of surfaces which may become contaminated by radioactive materials. Decontaminability data obtained using this test method are not applicable to technical systems where layers of contaminating materials are formed as a result of long-term application of higher temperatures and pressures (for example primary circuits of nuclear reactors). The purpose of the test is to assess the ease of decontamination of surfaces under laboratory conditions. In practical applications, it may be important to consider other qualities, such as chemical, mechanical and radiation resistance and long-term stability in the selection of the materials to be used. It should be recognized that further decontamination tests under simulated service conditions may be needed

  8. Testing the role of contaminants in depressing avian numbers Evaluando el rol de los contaminantes sobre la disminución del número de aves

    OpenAIRE

    WILLIAM H. KARASOV; MICHAEL W. MEYER

    2000-01-01

    Environmental contaminants are ubiquitous and so are often key suspects in cases of lagging wildlife populations. How do we test hypotheses about cause-effect linkages between contaminants and wildlife health? We present three case studies in which different approaches were used to test hypotheses about effects of contaminants on wildlife. The cases involve the possible impacts of (1) polychlorinated biphenyl on Lake Superior bald eagles (Haliaeetus leucocephalus); (2) dioxin on osprey (Pandi...

  9. Risk-based screening analysis of ground water contaminated by radionuclides introduced at the Nevada Test Site (NTS)

    International Nuclear Information System (INIS)

    Daniels, J.I.; Anspaugh, L.R.; Andricevic, R.; Jacobson, R.L.

    1993-06-01

    The Nevada Test Site (NTS) is located in the southwestern part of Nevada, about 105 km (65 mi) northwest of the city of Las Vegas. Underground tests of nuclear weapons devices have been conducted at the NTS since late 1962 and ground water beneath the NTS has been contaminated with radionuclides produced by these tests. This concern prompted this examination of the potential health risk to these individuals from drinking the contaminated ground water either at a location on the NTS (assuming loss of institutional control after 100 y) or at one offsite (considering groundwater migration). For the purpose of this assessment, a representative mix of the radionuclides of importance and their concentrations in ground water beneath the NTS were identified from measurements of radionuclide concentrations in groundwater samples-of-opportunity collected at the NTS. Transport of radionuclide-contaminated ground water offsite was evaluated using a travel-time-transport approach. At both locations of interest, potential human-health risk was calculated for an individual ingesting radionuclide-contaminated ground water over the course of a 70-y lifetime. Uncertainties about human physiological attributes, as well as about estimates of physical detriment per unit of radioactive material, were quantified and incorporated into the estimates of risk. The maximum potential excess lifetime risk of cancer mortality estimated for an individual at the offsite location ranges from 7 x 10 -7 to 1 x 10 -5 , and at the onsite location ranges from 3 x 10 -3 to 2 x 10 -2 . Both the offsite and the onsite estimates of risk are dominated by the lifetime doses from tritium. For the assessment of radionuclides in ground water, the critical uncertainty is their concentration today under the entire NTS

  10. Understanding Mechanisms of Radiological Contamination

    Energy Technology Data Exchange (ETDEWEB)

    Rick Demmer; John Drake; Ryan James, PhD

    2014-03-01

    Over the last 50 years, the study of radiological contamination and decontamination has expanded significantly. This paper addresses the mechanisms of radiological contamination that have been reported and then discusses which methods have recently been used during performance testing of several different decontamination technologies. About twenty years ago the Idaho Nuclear Technology Engineering Center (INTEC) at the INL began a search for decontamination processes which could minimize secondary waste. In order to test the effectiveness of these decontamination technologies, a new simulated contamination, termed SIMCON, was developed. SIMCON was designed to replicate the types of contamination found on stainless steel, spent fuel processing equipment. Ten years later, the INL began research into methods for simulating urban contamination resulting from a radiological dispersal device (RDD). This work was sponsored by the Defense Advanced Research Projects Agency (DARPA) and included the initial development an aqueous application of contaminant to substrate. Since 2007, research sponsored by the US Environmental Protection Agency (EPA) has advanced that effort and led to the development of a contamination method that simulates particulate fallout from an Improvised Nuclear Device (IND). The IND method diverges from previous efforts to create tenacious contamination by simulating a reproducible “loose” contamination. Examining these different types of contamination (and subsequent decontamination processes), which have included several different radionuclides and substrates, sheds light on contamination processes that occur throughout the nuclear industry and in the urban environment.

  11. The Use of the Molecular Adsorber Coating Technology to Mitigate Vacuum Chamber Contamination During Pathfinder Testing for the James Webb Space Telescope

    Science.gov (United States)

    Abraham, Nithin S.; Hasegawa, Mark M.; Wooldridge, Eve M.; Henderson-Nelson, Kelly A.

    2016-01-01

    As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground based space applications, in particular, for vacuum chamber environments. This paper describes the recent use of the MAC technology during Pathfinder testing of the Optical Ground Support Equipment (OGSE) for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap persistent outgassed contaminants, specifically silicone based diffusion pump oil, from within JSC's cryogenic optical vacuum chamber test facility called Chamber A. This paper summarizes the sample fabrication, installation, laboratory testing, post-test chemical analysis results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination.

  12. Contamination of broiler chickens with radiocaesium contaminated feed and its reduction

    International Nuclear Information System (INIS)

    Poeschl, M.

    2004-01-01

    The present study summarises information gleaned during investigations of the transfer of radiocaesium ( 137 Cs) and tests of countermeasures of a chemical character, i.e. feed additives limiting the transfer from the feed of broiler chicken. The regularities of the transport and distribution of radiocaesium in the organism (liver, kidneys, muscles, intestines) from feed were studied, including tests of the effect of the source of radiocaesium, date of administration and age of the chickens. The results confirmed that the retention of radiocaesium from feed into the body organs was very rapid (several hours) as was the release from the body (T 1/2b = 0.5-2 days) during the decontamination. Differences were discovered in the distribution and dynamics of the content of 137 Cs between breast and leg meat. The tests showed a very effective and relatively simple method of measuring the contaminated chickens in vivo. Special clay mineral or cellulose-based feed additives, and also modified hexacyanoferrates, especially when applied prior to contamination proper, considerably reduced the retention of radiocaesium into the breast and leg meat, and if the meat has already been contaminated, or if contamination was inevitable, the concentrations of 137 Cs in broiler chicken meat admissible for foodstuffs could be obtained much more quickly. (authors)

  13. The potential of compost-based biobarriers for Cr(VI) removal from contaminated groundwater: Column test

    International Nuclear Information System (INIS)

    Boni, Maria Rosaria; Sbaffoni, Silvia

    2009-01-01

    This paper presents the results of a column reactor test, aiming at evaluating the performance of a biological permeable barrier made of low-cost waste materials, for Cr(VI) removal from contaminated groundwater. A 1:1 by volume mixture of green compost and siliceous gravel was tested as reactive medium in the experimental activity. A 10 mg/l Cr(VI) contaminated solution was used and the residual Cr(VI) concentration along the column height and in the outlet was determined in the water samples collected daily. Also pH, redox potential and COD were analyzed. At the end of the test, the reactive medium was characterized in terms of Cr(VI) and total chromium. The Cr(VI) removal efficiency was higher than 99% during the entire experimental activity. The influence of the biological activity on Cr(VI) removal efficiency was evaluated by varying the organic carbon and nitrogen dosages in the contaminated solution fed to the system; a removal decrease was observed when the organic carbon was not enough to sustain the microbial metabolism. The Cr(VI) removal was strictly linked to the biological activity of the native biomass of compost. No Cr(III) was detected in the outlet: the Cr(III) produced was entrapped in the solid matrix. Two main processes involved were: adsorption on the organic-based matrix and reduction into Cr(III) mediated by the anaerobic microbial metabolism of the bacteria residing in green compost. Siliceous gravel was used as the structure matrix, since its contribution to the removal was almost negligible. Thanks to the proven efficiency and to the low-cost, the reactive medium used can represent a valid alternative to conventional approaches to chromium remediation.

  14. Liquid Oxygen Rotating Friction Ignition Testing of Aluminum and Titanium with Monel and Inconel for Rocket Engine Propulsion System Contamination Investigation

    Science.gov (United States)

    Peralta, S.; Rosales, Keisa R.; Stoltzfus, Joel M.

    2009-01-01

    Metallic contaminant was found in the liquid oxygen (LOX) pre-valve screen of the shuttle main engine propulsion system on two orbiter vehicles. To investigate the potential for an ignition, NASA Johnson Space Center White Sands Test Facility performed (modified) rotating friction ignition testing in LOX. This testing simulated a contaminant particle in the low-pressure oxygen turbo pump (LPOTP) and the high-pressure oxygen turbo pump (HPOTP) of the shuttle main propulsion system. Monel(R) K-500 and Inconel(R) 718 samples represented the LPOTP and HPOTP materials. Aluminum foil tape and titanium foil represented the contaminant particles. In both the Monel(R) and Inconel(R) material configurations, the aluminum foil tape samples did not ignite after 30 s of rubbing. In contrast, all of the titanium foil samples ignited regardless of the rubbing duration or material configuration. However, the titanium foil ignitions did not propagate to the Monel and Inconel materials.

  15. Development and Testing of an Air Fluorescence Imaging System for the Detection of Radiological Contamination

    International Nuclear Information System (INIS)

    Inrig, Elizabeth; Koslowsky, Vern; Andrews, Bob; Dick, Michael; Forget, Patrick; Ing, Harry; Hugron, Roger; Wong, Larry

    2011-01-01

    Detection of radionuclides emitting short-range radiation, such as α and low-energy β particles, has always presented a challenge, particularly when such radionuclides are dispersed over a wide area. In this situation, conventional detection methods require the area of interest to be surveyed using a fragile probe at very close range--a slow, error-prone, and potentially dangerous process that may take many hours for a single room. The instrument under development uses a novel approach by imaging radiation-induced fluorescence in the air surrounding a contaminated area, rather than detecting the radiation directly. A robust and portable system has been designed and built that will allow contaminated areas to be rapidly detected and delineated. The detector incorporates position-sensitive photo-multiplier tubes, UV filters, a fast electronic shutter and an aspherical phase mask that significantly increases the depth-of-field. Preliminary tests have been conducted using sealed 241 Am sources of varying activities and surface areas. The details of the instrument design will be described and the results of recent testing will be presented.

  16. Contamination analysis unit

    International Nuclear Information System (INIS)

    Gregg, H.R.; Meltzer, M.P.

    1996-01-01

    The portable Contamination Analysis Unit (CAU) measures trace quantities of surface contamination in real time. The detector head of the portable contamination analysis unit has an opening with an O-ring seal, one or more vacuum valves and a small mass spectrometer. With the valve closed, the mass spectrometer is evacuated with one or more pumps. The O-ring seal is placed against a surface to be tested and the vacuum valve is opened. Data is collected from the mass spectrometer and a portable computer provides contamination analysis. The CAU can be used to decontaminate and decommission hazardous and radioactive surfaces by measuring residual hazardous surface contamination, such as tritium and trace organics. It provides surface contamination data for research and development applications as well as real-time process control feedback for industrial cleaning operations and can be used to determine the readiness of a surface to accept bonding or coatings. 1 fig

  17. Use of the physiologically-based extraction test to assess the oral bioaccessibility of metals in vegetable plants grown in contaminated soil

    Energy Technology Data Exchange (ETDEWEB)

    Intawongse, Marisa [Biomolecular and Biomedical Research Centre, School of Applied Sciences, University of Northumbria at Newcastle, Ellison Building, Newcastle upon Tyne NE1 8ST (United Kingdom); Dean, John R. [Biomolecular and Biomedical Research Centre, School of Applied Sciences, University of Northumbria at Newcastle, Ellison Building, Newcastle upon Tyne NE1 8ST (United Kingdom)], E-mail: john.dean@unn.ac.uk

    2008-03-15

    The oral bioaccessibility of metals in vegetable plants grown on contaminated soil was assessed. This was done using the physiologically-based extraction test (PBET) to simulate the human digestion of plant material. A range of vegetable plants, i.e. carrot, lettuce, radish and spinach, were grown on metal contaminated soil. After reaching maturity the plants were harvested and analysed for their total metal content (i.e. Cr, Cd, Cu, Fe, Mn, Mo, Ni, Pb and Zn) by inductively coupled plasma-mass spectrometry (ICP-MS). The plant samples were then subsequently extracted using an in vitro gastrointestinal approach or PBET to assess the likelihood of oral bioaccessibility if the material was consumed by humans. - Evaluation of a physiologically-based extraction test to assess the risk to humans of consuming contaminated vegetables.

  18. Use of the physiologically-based extraction test to assess the oral bioaccessibility of metals in vegetable plants grown in contaminated soil

    International Nuclear Information System (INIS)

    Intawongse, Marisa; Dean, John R.

    2008-01-01

    The oral bioaccessibility of metals in vegetable plants grown on contaminated soil was assessed. This was done using the physiologically-based extraction test (PBET) to simulate the human digestion of plant material. A range of vegetable plants, i.e. carrot, lettuce, radish and spinach, were grown on metal contaminated soil. After reaching maturity the plants were harvested and analysed for their total metal content (i.e. Cr, Cd, Cu, Fe, Mn, Mo, Ni, Pb and Zn) by inductively coupled plasma-mass spectrometry (ICP-MS). The plant samples were then subsequently extracted using an in vitro gastrointestinal approach or PBET to assess the likelihood of oral bioaccessibility if the material was consumed by humans. - Evaluation of a physiologically-based extraction test to assess the risk to humans of consuming contaminated vegetables

  19. Contamination monitoring of Na 131 I levels in therapy unit of Research Institute for Nuclear Medicine, Tehran University of Medical Sciences by indirect method (Wipe test)

    International Nuclear Information System (INIS)

    Beiki, D.; Shahhosseini, S.; Eftekhari, M.; Takavar, A.; Fard-Esfahani, A.

    2003-01-01

    Contamination with radiopharmaceuticals in nuclear medicine centres in addition to being a health concern requires time consuming decontamination efforts. According to Nuclear Regulatory Commission Contamination should be monitored in nuclear medicine centers where radiopharmaceuticals are prepared and administrated at the end of each working session; otherwise, contamination spread to other areas not only equipment but also personnel and other people will be expected. The wipe test for the presence of radioactivity is accomplished by wiping the surface over an area approximately 100 cm 2 with an absorbent paper, then counting it in an appropriate radiation detector. In this study, contamination monitoring of patient's rooms (4 rooms), entrance corridor, patient's corridor, waiting room, control room (nursing station), radiopharmaceutical storage room in therapy unit of Research Institute for Nuclear Medicine, Shariati hospital was performed by indirect method. Based on the results, some areas including storage room were contaminated. There was also a direct relationship between dose administrated and levels of contamination in patient's rooms. Regarding high uptake of iodine by thyroid gland and damaging effects of Na 131 I, weekly wipe tests are required to determine the level of contamination. Patient's rooms after discharging the patients and before re hospitalization specially should be checked. If these tests reveal contamination over standard levels, appropriate decontamination procedures should be carried out immediately

  20. Results of EPR dosimetry for population in the vicinity of the most contaminating radioactive fallout trace after the first nuclear test in the Semipalatinsk test site

    International Nuclear Information System (INIS)

    Ivannikov, Alexander; Zhumadilov, Kassym; Tieliewuhan, Eldana

    2006-01-01

    The method of electron paramagnetic resonance (EPR) spectroscopy for tooth enamel is applied to individual radiation dose determination to residents of two villages (Dolon and Mostik) in the vicinity of the Semipalatinsk nuclear test site in Kazakhstan. These villages are located near the central axis of the radioactive fallout trace of the most contaminating surface nuclear test conducted in 1949. It is found that excess doses obtained by subtraction of natural background dose from dose absorbed in enamel range up to 440 mGy to residents of Dolon, whose enamel was formed before 1949, and do not exceed 120 mGy to younger residents. To residents of Mostik, excess doses do not exceed 100 mGy regardless of age except for one resident with an extremely high dose of 1.25 Gy. These results are in agreement with the pattern of radioactive contamination of the territory after the nuclear test of 1949 except one case of extremely high dose, which should be additionally investigated. (author)

  1. 9 CFR 113.30 - Detection of Salmonella contamination.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Detection of Salmonella contamination... REQUIREMENTS Standard Procedures § 113.30 Detection of Salmonella contamination. The test for detection of Salmonella contamination provided in this section shall be conducted when such a test is prescribed in an...

  2. 9 CFR 113.32 - Detection of Brucella contamination.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Detection of Brucella contamination... REQUIREMENTS Standard Procedures § 113.32 Detection of Brucella contamination. The test for detection of Brucella contamination provided in this section shall be conducted when such a test is prescribed in an...

  3. Field test and mathematical modeling of bioremediation of an oil-contaminated soil. Part 1: Field test

    International Nuclear Information System (INIS)

    Li, K.Y.; Xu, T.; Colapret, J.A.; Cawley, W.A.; Bonner, J.S.; Ernest, A.; Verramachaneni, P.B.

    1994-01-01

    A fire-wall area (about 270 ft x 310 ft) with the Bunker C oil contaminated soil was selected for the bioremediation field test. This fire-wall area was separated into 18 plots by dirt dikes to test 6 bioremediation methods with three tests of each method. The six treatment methods were: (a) aeration with basic nutrients and indigenous organisms (BNIO); (b) aeration with basic nutrients and inoculation from a refinery wastewater treatment facility (BNSIWT); (c) aeration with an oleophilic fertilizer and indigenous organisms (INIPOL); (d) aeration with basic nutrients and biosurfactant organisms (EPA Seal Beach consortia) (EPA); (e) aeration with proprietary nutrients and organisms (PRO); and (f) aeration only for active control (CONTROL). This field test was conducted for 91 days. In general the oil contents in 18 plots were reduced, but the results showed significant fluctuations. A statistical method was used to examine if the oil reductions of six methods were the results from the random error of sampling and sample analysis or biodegradation. The results of the statistical analysis showed that oil reduction was concluded from all but the plots of PRO. From the data analysis, it may be concluded that the oil reduction rate in these studies is controlled by oil transfer from soil into the aqueous solution. An example of calculation was used to illustrate this conclusion

  4. Revelations of an overt water contamination.

    Science.gov (United States)

    Singh, Gurpreet; Kaushik, S K; Mukherji, S

    2017-07-01

    Contaminated water sources are major cause of water borne diseases of public health importance. Usually, contamination is suspected after an increase in patient load. Two health teams investigated the episode. First team conducted sanitary survey, and second team undertook water safety and morbidity survey. On-site testing was carried out from source till consumer end. Investigation was also undertaken to identify factors which masked the situation. Prevention and control measures included super chlorination, provision of alternate drinking water sources, awareness campaign, layout of new water pipeline bypassing place of contamination, repair of sewers, flushing and cleaning of water pipelines, and repeated water sampling and testing. Multiple sources of drinking water supply were detected. Water samples from consumer end showed 18 coliforms per 100 ml. Sewer cross connection with active leakage in water pipeline was found and this was confirmed by earth excavation. Water safety and morbidity survey found majority of households receiving contaminated water supply. This survey found no significant difference among households receiving contaminated water supply and those receiving clean water. Average proportion of household members with episode of loose motions, pain abdomen, vomiting, fever, and eye conditions was significantly more among households receiving contaminated water. The present study documents detailed methodology of investigation and control measures to be instituted on receipt of contaminated water samples. Effective surveillance mechanisms for drinking water supplies such as routine testing of water samples can identify water contamination at an early stage and prevent an impending outbreak.

  5. Corrective Action Decision Document/Closure Report for Corrective Action Unit 529: Area 25 Contaminated Materials, Nevada Test Site, Nevada, Rev. No.: 1

    Energy Technology Data Exchange (ETDEWEB)

    Robert F. Boehlecke

    2004-11-01

    This Corrective Action Decision Document (CADD)/Closure Report (CR) has been prepared for Corrective Action Unit (CAU) 529, Area 25 Contaminated Materials, Nevada Test Site (NTS), Nevada, in accordance with the ''Federal Facility Agreement and Consent Order'' (FFACO) that was agreed to by the State of Nevada, U.S. Department of Energy (DOE), and the U.S. Department of Defense (FFACO, 1996). The NTS is approximately 65 miles (mi) northwest of Las Vegas, Nevada (Figure 1-1). Corrective Action Site (CAS) 25-23-17, Contaminated Wash, is the only CAS in CAU 529 and is located in Area 25 of the NTS, in Nye County, Nevada (Figure 1-2). Corrective Action Site 25-23-17, Contaminated Wash, was divided into nine parcels because of the large area impacted by past operations and the complexity of the source areas. The CAS was subdivided into separate parcels based on separate and distinct releases as determined and approved in the Data Quality Objectives (DQO) process and Corrective Action Investigation Plan (CAIP). Table 1-1 summarizes the suspected sources for the nine parcels. Corrective Action Site 25-23-17 is comprised of the following nine parcels: (1) Parcel A, Kiwi Transient Nuclear Test (TNT) 16,000-foot (ft) Arc Area (Kiwi TNT); (2) Parcel B, Phoebus 1A Test 8,000-ft Arc Area (Phoebus); (3) Parcel C, Topopah Wash at Test Cell C (TCC); (4) Parcel D, Buried Contaminated Soil Area (BCSA) l; (5) Parcel E, BCSA 2; (6) Parcel F, Borrow Pit Burial Site (BPBS); (7) Parcel G, Drain/Outfall Discharges; (8) Parcel H, Contaminated Soil Storage Area (CSSA); and (9) Parcel J, Main Stream/Drainage Channels.

  6. Development and field testing of a mobile chlorine dioxide generation system for the decontamination of buildings contaminated with Bacillus anthracis

    International Nuclear Information System (INIS)

    Wood, Joseph P.; Blair Martin, G.

    2009-01-01

    The numerous buildings that became contaminated with Bacillus anthracis (the bacterium causing the disease anthrax) in 2001, and more recent B. anthracis - related events, point to the need to have effective decontamination technologies for buildings contaminated with biological threat agents. The U.S. Government developed a portable chlorine dioxide (ClO 2 ) generation system to decontaminate buildings contaminated with B. anthracis spores, and this so-called mobile decontamination trailer (MDT) prototype was tested through a series of three field trials. The first test of the MDT was conducted at Fort McClellan in Anniston, AL. during October 2004. Four test attempts occurred over two weekends; however, a number of system problems resulted in termination of the activity prior to any ClO 2 introduction into the test building. After making several design enhancements and equipment changes, the MDT was subjected to a second test. During this test, extensive leak checks were made using argon and nitrogen in lieu of chlorine gas; each subsystem was checked for functionality, and the MDT was operated for 24 h. This second test demonstrated the MDT flow and control systems functioned satisfactorily, and thus it was decided to proceed to a third, more challenging field trial. In the last field test, ClO 2 was generated and routed directly to the scrubber in a 12-h continuous run. Measurement of ClO 2 levels at the generator outlet showed that the desired production rate was not achieved. Additionally, only one of the two scrubbers performed adequately with regard to maintaining ClO 2 emissions below the limit. Numerous lessons were learned in the field trials of this ClO 2 decontamination technology.

  7. Leaching study of contaminated and remediated soil and dredged sludge and development of a fast testing procedure for determining the leachability of contaminants; Uitloogonderzoek aan verontreinigde en gereinigde grond en baggerspecie en ontwikkeling van verkorte proceudres ter bepaling van de uitloging

    Energy Technology Data Exchange (ETDEWEB)

    Zevenbergen, C.; Frapporti, G.; Keyzer, J.; Heynen, J.J.M.

    1997-08-01

    A large study, performed jointly by ECN and IWACO, in which the effect of soil remediation on the leachability of contaminants from soils was investigated, is summarized. The study included two specific aims, which are treated in more detail in two separate reports: (1) The development of a fast testing procedure for determining the leachability of pollutants from contaminated and treated soils, which allows for an assessment relative to the regulatory limits stated in the Dutch Building Materials Decree; and (2) To develop a better understanding of the physico-chemical processes underlying the leachability of contaminants, including the development of a model for the leaching of pollutants from contaminated and treated soils and dredged sludge. The development of a fast testing procedure is reported in this report. The study of physico-chemical processes is reported in `Speciation of metals in contaminated and remediated soil and dredged sludge. Leaching processes and controlling factors` (ECN-C--96-084). The contaminants dealt with in this report are arsenic, copper, cadmium, mercury, lead, zinc, and cyanide, as well as a limited amount of contaminated and remediated aquatic sediments. 13 figs., 2 tabs, 8 refs.

  8. A laboratory test of NOM-assisted remediation of arsenic and copper contaminated soils

    DEFF Research Database (Denmark)

    Rasmussen, Signe Bonde; Jensen, Julie Katrine; Borggaard, Ole K.

    2015-01-01

    Soils contaminated by arsenic (As) and copper (Cu) must be remediated because As and Cu are non-degradable and toxic. On moderately contaminated soils, As and Cu may be removed by in-situ plant uptake (phytoremediation), whereas strongly contaminated soils must be removed and cleaned by soil...... at neutral pH to enhance in-situ phytoremediation of moderately contaminated soils. Citrate (and NTA) cannot be suggested for enhancement of on-site phytoremediation because of high mobilization rates caused by these extractants, which through leaching and runoff may lead to contamination of recipient waters...

  9. Status on contamination monitoring in China

    Energy Technology Data Exchange (ETDEWEB)

    Quanlu, Gou [China Institute for Radiation Protection, Taiyuan (China)

    1997-06-01

    The air contaminated by radioactive materials in nuclear enterprises and radioactive workplaces and forming radioactive aerosol and the leakage of radioactive materials in operation cause internal exposure damage in workers. It is necessary and important to monitor air and surface contaminations for the health of public and workers, and for protecting environment. At present, many institutes engage in the studies on surface contamination monitoring in China, and the government has formulated the control limits of surface contamination in the Regulations of Radiation Protection. The monitors for surface contamination monitoring are almost home-made. The methods being used often are smear test and placing surface sample test. Scintillation counters, semiconductor detectors and G-M counters have been used for detecting alpha surface contamination. Plastic scintillator meters and thin wall/window G-M counters are used for beta surface contamination. Special detectors have been designed for monitoring low energy nuclides. The status of airborne contamination monitoring in China is reported. As the studies for future, the development of the surface contamination monitor for low energy beta nuclides, especially H-3, the monitoring methods for the special shapes of surfaces, the technology of decontamination and the calibration method and device for on-line radioactive aerosol continuous monitors are taken up. (K.I.)

  10. Geotechnical properties of oil-contaminated Kuwaiti sand

    Energy Technology Data Exchange (ETDEWEB)

    Al-Sanad, H.A.; Eid, W.K.; Ismael, N.F. [Kuwait Univ., Safat (Kuwait). Dept. of Civil Engineering

    1995-05-01

    Large quantities of oil-contaminated sands resulted from exploded oil wells, burning oil fires, the destruction of oil storage tanks, and the formation of oil lakes in Kuwait at the end of the Gulf War. An extensive laboratory testing program was carried out to determine the geotechnical characteristics of this material. Testing included basic properties, compaction and permeability tests, and triaxial and consolidation tests on clean and contaminated sand at the same relative density. Contaminated specimens were prepared by mixing the sand with oil in the amount of 6% by weight or less to match field conditions. The influence of the type of oil, and relative density was also investigated by direct shear tests. The results indicated a small reduction in strength and permeability and an increase in compressibility due to contamination. The preferred method of disposal of this material is to use it as a stabilizing material for other projects such as road construction.

  11. Geotechnical properties of oil-contaminated Kuwaiti sand

    International Nuclear Information System (INIS)

    Al-Sanad, H.A.; Eid, W.K.; Ismael, N.F.

    1995-01-01

    Large quantities of oil-contaminated sands resulted from exploded oil wells, burning oil fires, the destruction of oil storage tanks, and the formation of oil lakes in Kuwait at the end of the Gulf War. An extensive laboratory testing program was carried out to determine the geotechnical characteristics of this material. Testing included basic properties, compaction and permeability tests, and triaxial and consolidation tests on clean and contaminated sand at the same relative density. Contaminated specimens were prepared by mixing the sand with oil in the amount of 6% by weight or less to match field conditions. The influence of the type of oil, and relative density was also investigated by direct shear tests. The results indicated a small reduction in strength and permeability and an increase in compressibility due to contamination. The preferred method of disposal of this material is to use it as a stabilizing material for other projects such as road construction

  12. The integrated contaminant elution and tracer test toolkit, ICET3, for improved characterization of mass transfer, attenuation, and mass removal

    Science.gov (United States)

    Brusseau, Mark L.; Guo, Zhilin

    2018-01-01

    It is evident based on historical data that groundwater contaminant plumes persist at many sites, requiring costly long-term management. High-resolution site-characterization methods are needed to support accurate risk assessments and to select, design, and operate effective remediation operations. Most subsurface characterization methods are generally limited in their ability to provide unambiguous, real-time delineation of specific processes affecting mass-transfer, transformation, and mass removal, and accurate estimation of associated rates. An integrated contaminant elution and tracer test toolkit, comprising a set of local-scale groundwater extraction-and injection tests, was developed to ameliorate the primary limitations associated with standard characterization methods. The test employs extended groundwater extraction to stress the system and induce hydraulic and concentration gradients. Clean water can be injected, which removes the resident aqueous contaminant mass present in the higher-permeability zones and isolates the test zone from the surrounding plume. This ensures that the concentrations and fluxes measured within the isolated area are directly and predominantly influenced by the local mass-transfer and transformation processes controlling mass removal. A suite of standard and novel tracers can be used to delineate specific mass-transfer and attenuation processes that are active at a given site, and to quantify the associated mass-transfer and transformation rates. The conceptual basis for the test is first presented, followed by an illustrative application based on simulations produced with a 3-D mathematical model and a brief case study application.

  13. Effects of blood contamination of cerebrospinal fluid on results of indirect fluorescent antibody tests for detection of antibodies against Sarcocystis neurona and Neospora hughesi.

    Science.gov (United States)

    Finno, Carrie J; Packham, Andrea E; David Wilson, W; Gardner, Ian A; Conrad, Patricia A; Pusterla, Nicola

    2007-05-01

    The purpose of this study was to determine the effect of blood contamination of cerebrospinal fluid (CSF) on the results of indirect fluorescent antibody tests (IFATs) for Sarcocystis neurona and Neospora hughesi. The in vitro study used antibody-negative CSF collected from non-neurologic horses immediately after euthanasia and blood samples from 40 healthy horses that had a range of IFAT antibody titers against S. neurona and N. hughesi. Serial dilutions of whole blood were made in seronegative CSF to generate blood-contaminated CSF with red blood cell (RBC) concentrations ranging from 10 to 100,000 RBCs/microl. The blood-contaminated CSF samples were then tested for antibodies against both pathogens using IFAT. Blood contamination of CSF had no detectable effect on IFAT results for S. neurona or N. hughesi at any serologic titer when the RBC concentration in CSF was or=5) for S. neurona and N. hughesi were detected only when the corresponding serum titers were >or=160 and >or=80, respectively. The IFAT performed on CSF is reliable for testing horses for equine protozoal myeloencephalitis caused by S. neurona or N. hughesi, even when blood contamination causes the RBC concentration in CSF to be up to 10,000 RBCs/microl.

  14. Evaluation of microcystin contamination in blue-green algal dietary supplements using a protein phosphatase inhibition-based test kit.

    Science.gov (United States)

    Marsan, David W; Conrad, Stephen M; Stutts, Whitney L; Parker, Christine H; Deeds, Jonathan R

    2018-03-01

    The cyanobacterium Aphanizomenon flos-aquae (AFA), from Upper-Klamath Lake, Oregon, are used to produce blue-green algal (BGA) dietary supplements. The periodic co-occurrence of hepatotoxin-producing contaminant species prompted the Oregon Health Division to establish a limit of 1 μg/g microcystin (MC) for products sold in Oregon in 1997. At the federal level, the current good manufacturing practice (CGMP) regulations for dietary supplements require manufacturers establish a specification, and test, for limits on contaminants that may adulterate finished products. Despite this, several previous international surveys reported MC in BGA supplements in excess of 1 μg/g. The objectives of this study were (1) identify a reliable, easy to use test kit for the detection of MC in dried BGA materials and (2) use this kit to assess the occurrence of MC contamination in AFA-BGA dietary supplements in the U.S. A commercial protein phosphatase inhibition assay (PPIA), based on the enzyme PP2A, was found to have acceptable relative enzyme inhibition and accuracy for the majority of MC variants tested, including those most commonly identified in commercial samples, making the kit fit for purpose. Using the PPIA kit, 51% (26 of 51) distinct AFA-BGA products had MC ≥0.25 μg/g (the detection limit of the kit), 10 products had MC concentrations between 0.5 and 1.0 μg/g, and 4 products exceeded the limit (1.1-2.8 μg/g). LC-MS/MS confirmed PPIA results ≥0.5 μg/g and determined that MC-LA and MC-LR were the main congeners present. PPIA is a reliable method for the detection of MC contamination in dried BGA dietary supplements produced in the U.S. While the majority of AFA-BGA products contained ≥0.25 μg/g MC, most were at or below 1.0 μg/g, suggesting that manufacturers have adopted this level as a specification in these products; however, variability in recommended serving sizes prevented further analysis of consumer exposure based on the concentrations of MC

  15. Evaluation of microcystin contamination in blue-green algal dietary supplements using a protein phosphatase inhibition-based test kit

    Directory of Open Access Journals (Sweden)

    David W. Marsan

    2018-03-01

    Full Text Available The cyanobacterium Aphanizomenon flos-aquae (AFA, from Upper-Klamath Lake, Oregon, are used to produce blue-green algal (BGA dietary supplements. The periodic co-occurrence of hepatotoxin-producing contaminant species prompted the Oregon Health Division to establish a limit of 1 μg/g microcystin (MC for products sold in Oregon in 1997. At the federal level, the current good manufacturing practice (CGMP regulations for dietary supplements require manufacturers establish a specification, and test, for limits on contaminants that may adulterate finished products. Despite this, several previous international surveys reported MC in BGA supplements in excess of 1 μg/g. The objectives of this study were (1 identify a reliable, easy to use test kit for the detection of MC in dried BGA materials and (2 use this kit to assess the occurrence of MC contamination in AFA-BGA dietary supplements in the U.S. A commercial protein phosphatase inhibition assay (PPIA, based on the enzyme PP2A, was found to have acceptable relative enzyme inhibition and accuracy for the majority of MC variants tested, including those most commonly identified in commercial samples, making the kit fit for purpose. Using the PPIA kit, 51% (26 of 51 distinct AFA-BGA products had MC ≥0.25 μg/g (the detection limit of the kit, 10 products had MC concentrations between 0.5 and 1.0 μg/g, and 4 products exceeded the limit (1.1–2.8 μg/g. LC-MS/MS confirmed PPIA results ≥0.5 μg/g and determined that MC-LA and MC-LR were the main congeners present. PPIA is a reliable method for the detection of MC contamination in dried BGA dietary supplements produced in the U.S. While the majority of AFA-BGA products contained ≥0.25 μg/g MC, most were at or below 1.0 μg/g, suggesting that manufacturers have adopted this level as a specification in these products; however, variability in recommended serving sizes prevented further analysis of consumer exposure based on the concentrations of MC

  16. Closure Report for Corrective Action Unit 143: Area 25 Contaminated Waste Dumps, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    Tobiason, D. S.

    2002-01-01

    This Closure Report (CR) has been prepared for the Area 25 Contaminated Waste Dumps (CWD), Corrective Action Unit (CAU) 143 in accordance with the Federal Facility Agreement and Consent Order [FFACO] (FFACO, 1996) and the Nevada Division of Environmental Protection (NDEP)-approved Corrective Action Plan (CAP) for CAU 143: Area 25, Contaminated Waste Dumps, Nevada Test Site, Nevada. CAU 143 consists of two Corrective Action Sites (CASs): 25-23-09 CWD No.1, and 25-23-03 CWD No.2. The Area 25 CWDs are historic disposal units within the Area 25 Reactor Maintenance, Assembly, and Disassembly (R-MAD), and Engine Maintenance, Assembly, and Disassembly (E-MAD) compounds located on the Nevada Test Site (NTS). The R-MAD and E-MAD facilities originally supported a portion of the Nuclear Rocket Development Station in Area 25 of the NTS. CWD No.1 CAS 25-23-09 received solid radioactive waste from the R-MAD Compound (East Trestle and West Trench Berms) and 25-23-03 CWD No.2 received solid radioactive waste from the E-MAD Compound (E-MAD Trench)

  17. The measurement test of uranium in a uranium-contaminated waste by passive gamma-rays measurement method

    CERN Document Server

    Sukegawa, Y; Ohki, K; Suzuki, S; Yoshida, M

    2002-01-01

    This report is completed about the measurement test and the proofreading of passive gamma - rays measurement method for Non - destructive assay of uranium in a uranium-contaminated waste. The following are the results of the test. 1) The estimation of the amount of uranium by ionization survey meter is difficult for low intensity of gamma-rays emitted from uranium under about 50g. 2) The estimation of the amount of uranium in the waste by NaI detector is possible in case of only uranium, but the estimation from mixed spectrums with transmission source (60-cobalt) is difficult to confirm target peaks. 3) If daughter nuclides of uranium and thorium chain of uranium ore exist, measurement by NaI detector is affected by gamma-rays from the daughter nuclides seriously-As a result, the estimation of the amount of uranium is difficult. 4) The measurement of uranium in a uranium-contaminated waste by germanium detector is possible to estimate of uranium and other nuclides. 5) As to estimation of the amount of uranium...

  18. Acute and chronic toxicity testing of TPH-contaminated soils with the earthworm, Eisenia foetida

    International Nuclear Information System (INIS)

    Stewart, A.J.; Wicker, L.F.; Nazerias, M.S.

    1995-01-01

    Responses of Eisenia foetida to petroleum-contaminated soils are being assessed using a 21-day test described previously. The authors prepared dilutions of two soils, referred to as A and B, using their reference-soil counterparts, collected from near the contaminated sites. The total petroleum hydrocarbon (TPH) content of each soil was measured by latroscan before the dilutions were prepared. References for the A and B soils contained 167 and 1,869 ppm of TPH, respectively. Thus, neither reference soil was pristine. Dilutions of the A soil tested with E. foetida contained from 179 to 305 ppm TPH; dilutions of the B soil contained from 1,875 to 1,950 ppm TPH. E foetida survival was 100% in both dilution series. Mean growth of Eisenia in dilutions of the A soil ranged from 48 to 74 mg dry-weight growth per pair of worms; these values were lower than those in any dilution of the B soil series. Lipid levels of worms in higher concentrations of the A and B soils were similar to one another and to published values, suggesting little inhibition of feeding in either dilution series. Earthworm reproduction was zero in the A series, but moderately high in the B series. Thus, the A soil apparently contained materials other than TPH that inhibited earthworm growth and reproduction. This study shows that (1) TPH at concentrations as high as 1,800 ppm may not always be inhibitor to earthworm growth or reproduction and (2) that earthworm survival, as a test endpoint, is much less sensitive than either growth or reproduction

  19. Testing of in situ and ex situ bioremediation approaches for an oil-contaminated peat bog following a pipeline break

    International Nuclear Information System (INIS)

    Wilson, J.J.; Lee, D.W.; Yeske, B.M.; Kuipers, F.

    2000-01-01

    The feasibility of treating a 1985 pipeline spill of light Pembina Cardium crude oil at a bog near Violet Grove, Alberta was discussed. Pembina Pipeline Corporation arranged for a treatability test to be conducted on oil-contaminated sphagnum peat moss from the site to determine effective in situ or ex situ remediation options for the site. The test was used to evaluate the biodegradation potential of contaminants. Four tests were designed to simulate field different field treatment approaches and to collect critical data on toxicity and leachability of the peat moss. The tests included a bioslurry test, a soil microcosm test, an aerated water saturated peat column test, and a standard toxicity characteristic leachate potential test. The first three tests gave similar results of at least 74 per cent biodegradation of the residual crude oil on the peat solids and no residual toxicity as measured by the Microtox Assay. It was determined that both in situ bioremediation using an aerated water injection system or an ex situ landfarming approach would achieve required criteria and no fertilizers would be necessary to maintain active bioremediation. The new gas-liquid reactor (GLR) aeration technology used in these tests creates a constant supply of hyperoxygenated water prior to column injection. The continuous release of tiny air bubbles maximizes air surface area and increases the gas transfer rates. 3 tabs., 3 figs

  20. JPL Contamination Control Engineering

    Science.gov (United States)

    Blakkolb, Brian

    2013-01-01

    JPL has extensive expertise fielding contamination sensitive missions-in house and with our NASA/industry/academic partners.t Development and implementation of performance-driven cleanliness requirements for a wide range missions and payloads - UV-Vis-IR: GALEX, Dawn, Juno, WFPC-II, AIRS, TES, et al - Propulsion, thermal control, robotic sample acquisition systems. Contamination control engineering across the mission life cycle: - System and payload requirements derivation, analysis, and contamination control implementation plans - Hardware Design, Risk trades, Requirements V-V - Assembly, Integration & Test planning and implementation - Launch site operations and launch vehicle/payload integration - Flight ops center dot Personnel on staff have expertise with space materials development and flight experiments. JPL has capabilities and expertise to successfully address contamination issues presented by space and habitable environments. JPL has extensive experience fielding and managing contamination sensitive missions. Excellent working relationship with the aerospace contamination control engineering community/.

  1. Development and successful field tests of a multi-process phytoremediation system for decontamination of persistent petroleum and organic contaminants in soil

    Energy Technology Data Exchange (ETDEWEB)

    Greenberg, B.M.; Huang, X.-D.; Gurska, Y.; Gerhardt, K.E.; Lampi, M.A.; Khalid, A.; Isherwood, D.; Chang, P.; Wang, W.; Wang, H.; Dixon, D.G.; Glick, B.R. [Waterloo Univ., ON (Canada). Dept. of Biology

    2006-07-01

    If efficient systems with rapid remediation kinetics can be realized, phytoremediation of persistent contaminants from soils holds great promise. A multi-process phytoremediation system (MPPS) with accelerated remediation kinetics that effectively removes polycyclic aromatic hydrocarbons (PAHs), total petroleum hydrocarbons (TPHs) and chlorinated hydrocarbons (CHCs) from soils has been developed. A plant growth promoting rhizobacteria interaction is the main element for success as it mitigates stress ethylene effects in plants, leading to high root biomass which, in turn, promotes growth of rhizosphere organisms. Based on the success of greenhouse experiments, field tests of the MPPS were initiated at an Imperial Oil land farm site in Sarnia, Ontario in the summer of 2004, followed by 127 field tests at the same site in the summer of 2005 and 2006. In addition, a total petroleum hydrocarbons (TPH) contaminated site in Alberta was used in 2005 and 2006. The study presented and discussed selected results of successful greenhouse, pilot field tests and field tests of the MPPS. It was concluded that increased root biomass is achieved in the contaminated soils, which leads to more efficient and complete removal of TPHs in the field. Three years of field trials of the MPPS showed that remediation continues with successive seasons. 27 refs., 2 tabs., 1 fig.

  2. Decontamination efficiency of detergents on the market for the skin contaminated with radioactive materials. The comparative test (1)

    International Nuclear Information System (INIS)

    Miyabe, Kenjiro; Ninomiya, Kazushi; Takasaki, Koji; Horiuchi, Nobuharu; Yasunaka, Hideo; Izumi, Yuichi

    1999-04-01

    Contamination incidence on human body and skin happens sometimes during radiation works in controlled area. The radioactive surface contamination should be removed from the skin as soon as possible for radiation control and exposure management. Titanium oxide paste, which is reserved as a detergent for decontamination, has a satisfactory and reliable result for decontamination effects. The titanium oxide paste, however, has a short preservation period, and must be updated and supplied every serenal months. Decontamination tests for about 60 kinds of detergents on the market were carried out with swine and radioactive material, Ce-144. Radioactive solution of Ce-144 was dropped on the test samples of swine skin, which were left for 5 min or 40 min as it is. Radioactivities of the samples were measured before and after washing by the detergents. As a result of the decontamination tests, 22 kinds of detergents on the market which have a similar decontamination efficiency to the titanium oxide paste were selected. It was also ascertained that the decontamination efficiency of all the detergents decreased on the test samples which were immersed in the radioactive solution for 40 min and wounded on skin surface. (Suetake, M.)

  3. Model testing for the remediation assessment of a radium contaminated site in Olen, Belgium

    International Nuclear Information System (INIS)

    Sweeck, Lieve; Kanyar, Bela; Krajewski, Pawel; Kryshev, Alexander; Lietava, Peter; Nenyei, Arpad; Sazykina, Tatiana; Yu, Charley; Zeevaert, Theo

    2005-01-01

    Environmental assessment models are used as decision-aiding tools in the selection of remediation options for radioactively contaminated sites. In most cases, the effectiveness of the remedial actions in terms of dose savings cannot be demonstrated directly, but can be established with the help of environmental assessment models, through the assessment of future radiological impacts. It should be emphasized that, given the complexity of the processes involved and our current understanding of how they operate, these models are simplified descriptions of the behaviour of radionuclides in the environment and therefore imperfect. One way of testing and improving the reliability of the models is to compare their predictions with real data and/or the predictions of other models. Within the framework of the Remediation Assessment Working Group (RAWG) of the BIOMASS (BIOsphere Modelling and ASSessment) programme coordinated by IAEA, two scenarios were constructed and applied to test the reliability of environmental assessment models when remedial actions are involved. As a test site, an area of approximately 100 ha contaminated by the discharges of an old radium extraction plant in Olen (Belgium) has been considered. In the first scenario, a real situation was evaluated and model predictions were compared with measured data. In the second scenario the model predictions for specific hypothetical but realistic situations were compared. Most of the biosphere models were not developed to assess the performance of remedial actions and had to be modified for this purpose. It was demonstrated clearly that the modeller's experience and familiarity with the mathematical model, the site and with the scenario play a very important role in the outcome of the model calculations. More model testing studies, preferably for real situations, are needed in order to improve the models and modelling methods and to expand the areas in which the models are applicable

  4. Phytoremediation of Soils Contaminated by Chlorinnated Hydrocarbons

    Science.gov (United States)

    Cho, C.; Sung, K.; Corapcioglu, M.

    2001-12-01

    In recent years, the possible use of deep rooted plants for phytoremediation of soil contaminants has been offered as a potential alternative for waste management, particularly for in situ remediation of large volumes of contaminated soils. Major objectives of this study are to evaluate the effectiveness of a warm season grass (Eastern Gamagrass) and a cool season prairie grass (Annual Ryegrass) in the phytoremediation of the soil contaminated with volatile organic compounds e.g., trichloroethylene (TCE), tetrachloroethylene (PCE), and 1,1,1-trichloroethane (TCA) and to determine the main mechanisms of target contaminant dissipation. The preliminary tests and laboratory scale tests were conducted to identify the main mechanisms for phytoremediation of the target contaminants, and to apply the technique in green house application under field conditions. The results of microcosm and bioreactor experiments showed that volatilization can be the dominant pathway of the target contaminant mass losses in soils. Toxicity tests, conducted in nutrient solution in the growth room, and in the greenhouse, showed that both Eastern gamagrass and Annual ryegrass could grow without harmful effects at up to 400 ppm each of all three contaminants together. Preliminary greenhouse experimentw were conducted with the 1.5 m long and 0.3 m diameter PVC columns. Soil gas concentrations monitored and microbial biomass in bulk and rhizosphere soil, root properties, and contaminant concentration in soil after 100 days were analyzed. The results showed that the soil gas concentration of contaminants has rapidly decreased especially in the upper soil and the contaminant concentraitons in soil were also significantly decreased to 0.024, 0.228, and 0.002 of C/Co for TCE, PCE and TCA, respectively. Significant plant effects were not found however showed contaminant loss through volatilization and plant contamination by air.

  5. New methodology to investigate potential contaminant mass fluxes at the stream-aquifer interface by combining integral pumping tests and streambed temperatures

    International Nuclear Information System (INIS)

    Kalbus, E.; Schmidt, C.; Bayer-Raich, M.; Leschik, S.; Reinstorf, F.; Balcke, G.U.; Schirmer, M.

    2007-01-01

    The spatial pattern and magnitude of mass fluxes at the stream-aquifer interface have important implications for the fate and transport of contaminants in river basins. Integral pumping tests were performed to quantify average concentrations of chlorinated benzenes in an unconfined aquifer partially penetrated by a stream. Four pumping wells were operated simultaneously for a time period of 5 days and sampled for contaminant concentrations. Streambed temperatures were mapped at multiple depths along a 60 m long stream reach to identify the spatial patterns of groundwater discharge and to quantify water fluxes at the stream-aquifer interface. The combined interpretation of the results showed average potential contaminant mass fluxes from the aquifer to the stream of 272 μg m -2 d -1 MCB and 71 μg m -2 d -1 DCB, respectively. This methodology combines a large-scale assessment of aquifer contamination with a high-resolution survey of groundwater discharge zones to estimate contaminant mass fluxes between aquifer and stream. - We provide a new methodology to quantify the potential contaminant mass flux from an aquifer to a stream

  6. Development of automatic smear testing sampler for radioactive contamination of floor in nuclear power plant

    International Nuclear Information System (INIS)

    Nozawa, Katsuro; Hashimoto, Hiroshi; Shinohara, Yohtaro; Iwaki, Kiyotaka

    1980-01-01

    The floor contamination with radioactive substances in the controlled area of nuclear power stations is strictly controlled, and it is tested by the smear method, wiping the contaminants on floors with filter papers or cloths and measuring the radioactive intensity to obtain contamination density. The works are very laborious, therefore the automatic smear sampler was developed. Simple operation, shortening of time required for wiping, constant and high efficiency of wiping, and easy numbering of samples were the aims in the development. The method of wiping, the mechanisms of wiping, cloth feeding and running, the surface pressure at the time of wiping, the number of times of wiping and required motor torque were studied. The outline of the developed sampler is explained. The performance of the sampler was compared with manual wiping. The efficiency of wiping with the sampler was 92%, assuming manual wiping as 100. Difference was not observed between careful manual wiping and the wiping with the sampler, therefore it was confirmed that this automatic floor smear sampler can be put in practical use. By conventional manual sampling, the maximum limit was about 400 samples/man-day, but when this sampler is used, about 1000 samples/sampler-day is possible. At present, this sampler is operated in Hamaoka Nuclear Power Station. (Kako, I.)

  7. Nuclear-physical methods in macro- and microanalytical investigations of contamination with radionuclides at Semipalatinsk Nuclear Test Site

    International Nuclear Information System (INIS)

    Solodukhin, V.P.

    2005-01-01

    A complex of nuclear-physical methods developed in the Institute of Nuclear Physics of Kazakhstan National Nuclear Center for the investigations of the rate, character and peculiarities of contamination with radionuclides of the Semipalatinsk Nuclear Test Site (SNTS) is presented. The developed method combines both macroinvestigations (radionuclide analysis, NAA, XRFA, ESR- and NGR-spectroscopy) and microinvestigations (MS, micro-PIXE, electron microscopy). The results of the investigations at the main SNTS test sites 'Opytnoye pole' and 'Degelen' are presented. (author)

  8. Plants growing on contaminated and brownfield sites appropriate for use in Organisation for Economic Co-operation and Development terrestrial plant growth test.

    Science.gov (United States)

    Sinnett, Danielle E; Lawrence, Victoria K; Hutchings, Tony R; Hodson, Mark E

    2011-01-01

    The Organisation for Economic Co-operation and Development (OECD) terrestrial plant test is often used for the ecological risk assessment of contaminated land. However, its origins in plant protection product testing mean that the species recommended in the OECD guidelines are unlikely to occur on contaminated land. Six alternative species were tested on contaminated soils from a former Zn smelter and a metal fragmentizer with elevated concentrations of Cd, Cu, Pb, and Zn. The response of the alternative species was compared with that of two species recommended by the OECD: Lolium perenne (perennial ryegrass) and Trifolium pratense (red clover). Urtica dioica (stinging nettle) and Poa annua (annual meadowgrass) had low emergence rates in the control soil and so may be considered unsuitable. Festuca rubra (Chewings fescue), Holcus lanatus (Yorkshire fog), Senecio vulgaris (common groundsel), and Verbascum thapsus (great mullein) offer good alternatives to the OECD species. In particular, H. lanatus and S. vulgaris were more sensitive to the soils with moderate concentrations of Cd, Cu, Pb, and Zn than the OECD species. © 2010 SETAC.

  9. Pros and cons of analytical methods to quantify surrogate contaminants from the challenge test in recycled polyethylene terephthalate

    Energy Technology Data Exchange (ETDEWEB)

    Felix, Juliana S., E-mail: jfelix@unizar.es [Department of Analytical Chemistry, Aragon Institute of Engineering Research (I3A), CPS, University of Zaragoza, Torres Quevedo Bldg., Maria de Luna St. 3, E-50018 Zaragoza (Spain); Alfaro, Pilar, E-mail: palfarot@unizar.es [Department of Analytical Chemistry, Aragon Institute of Engineering Research (I3A), CPS, University of Zaragoza, Torres Quevedo Bldg., Maria de Luna St. 3, E-50018 Zaragoza (Spain); Nerin, Cristina, E-mail: cnerin@unizar.es [Department of Analytical Chemistry, Aragon Institute of Engineering Research (I3A), CPS, University of Zaragoza, Torres Quevedo Bldg., Maria de Luna St. 3, E-50018 Zaragoza (Spain)

    2011-02-14

    Different analytical methods were optimized and applied to quantify certain surrogate contaminants (toluene, chlorobenzene, phenol, limonene and benzophenone) in samples of contaminated and recycled flakes and virgin pellets of polyethylene terephthalate (PET) coming from the industrial challenge test. A screening analysis of the PET samples was carried out by direct solid-phase microextraction (SPME) in headspace mode (HS). The methods developed and used for quantitative analysis were a) total dissolution of PET samples in dichloroacetic acid and analysis by HS-SPME coupled to gas chromatography-mass spectrometry (GC-MS) and, b) dichloromethane extraction and analysis by GC-MS. The concentration of all surrogates in the contaminated PET flakes analyzed by HS-SPME method was lower than expected according to information provided by the supplier. Dichloroacetic acid interacted with the surrogates, resulting in a tremendous decrease of limonene concentration. The degradation compounds from limonene were identified. Dichloromethane extraction and GC-MS analysis evidenced the highest values of analytes in these PET samples. Based on the foregoing data, the efficiency of the recycling process was evaluated, whereby the removal of 99.9% of the surrogates proceeding from the contaminated flakes was confirmed.

  10. Pros and cons of analytical methods to quantify surrogate contaminants from the challenge test in recycled polyethylene terephthalate

    International Nuclear Information System (INIS)

    Felix, Juliana S.; Alfaro, Pilar; Nerin, Cristina

    2011-01-01

    Different analytical methods were optimized and applied to quantify certain surrogate contaminants (toluene, chlorobenzene, phenol, limonene and benzophenone) in samples of contaminated and recycled flakes and virgin pellets of polyethylene terephthalate (PET) coming from the industrial challenge test. A screening analysis of the PET samples was carried out by direct solid-phase microextraction (SPME) in headspace mode (HS). The methods developed and used for quantitative analysis were a) total dissolution of PET samples in dichloroacetic acid and analysis by HS-SPME coupled to gas chromatography-mass spectrometry (GC-MS) and, b) dichloromethane extraction and analysis by GC-MS. The concentration of all surrogates in the contaminated PET flakes analyzed by HS-SPME method was lower than expected according to information provided by the supplier. Dichloroacetic acid interacted with the surrogates, resulting in a tremendous decrease of limonene concentration. The degradation compounds from limonene were identified. Dichloromethane extraction and GC-MS analysis evidenced the highest values of analytes in these PET samples. Based on the foregoing data, the efficiency of the recycling process was evaluated, whereby the removal of 99.9% of the surrogates proceeding from the contaminated flakes was confirmed.

  11. Reproducibility of up-flow column percolation tests for contaminated soils.

    Directory of Open Access Journals (Sweden)

    Tetsuo Yasutaka

    Full Text Available Up-flow column percolation tests are used at laboratory scale to assess the leaching behavior of hazardous substance from contaminated soils in a specific condition as a function of time. Monitoring the quality of these test results inter or within laboratory is crucial, especially if used for Environment-related legal policy or for routine testing purposes. We tested three different sandy loam type soils (Soils I, II and III to determine the reproducibility (variability inter laboratory of test results and to evaluate the difference in the test results within laboratory. Up-flow column percolation tests were performed following the procedure described in the ISO/TS 21268-3. This procedure consists of percolating solution (calcium chloride 1 mM from bottom to top at a flow rate of 12 mL/h through softly compacted soil contained in a column of 5 cm diameter and 30 ± 5 cm height. Eluate samples were collected at liquid-to-solid ratio of 0.1, 0.2, 0.5, 1, 2, 5 and 10 L/kg and analyzed for quantification of the target elements (Cu, As, Se, Cl, Ca, F, Mg, DOC and B in this research. For Soil I, 17 institutions in Japan joined this validation test. The up-flow column experiments were conducted in duplicate, after 48 h of equilibration time and at a flow rate of 12 mL/h. Column percolation test results from Soils II and III were used to evaluate the difference in test results from the experiments conducted in duplicate in a single laboratory, after 16 h of equilibration time and at a flow rate of 36 mL/h. Overall results showed good reproducibility (expressed in terms of the coefficient of variation, CV, calculated by dividing the standard deviation by the mean, as the CV was lower than 30% in more than 90% of the test results associated with Soil I. Moreover, low variability (expressed in terms of difference between the two test results divided by the mean was observed in the test results related to Soils II and III, with a variability lower than 30

  12. The bacterial contamination rate of glucose meter test strips in the hospital setting

    Science.gov (United States)

    Al-Rubeaan, Khalid A.; Saeb, Amr T. M.; AlNaqeb, Dhekra M.; AlQumaidi, Hamed M.; AlMogbel, Turki A.

    2016-01-01

    Objectives: To assess the rate of bacterial contamination of the multi-use vial and single-use packed glucose meter strips, and to identify the type and frequency of various bacterial contamination in different hospital wards. Methods: This prospective observational study was conducted by a team from the Strategic Center for Diabetes Research in 7 general hospitals in the Central region of Saudi Arabia during the period from August to September 2014 to assess the bacterial contamination rate of the unused strips. A total of 10,447 strips were cultured using proper agar media and incubated both aerobically and anaerobically. Results: The total bacterial contamination rate for the multi-use vials glucose strips was 31.7%, while single-use packed strips were not contaminated at all. Ministry of Health hospitals had the highest contamination rates compared with other hospitals. Critical, obstetric, and surgical wards had the highest bacterial isolates number, where most were in the risk group 3 according to the National Institute of Health guidelines. Staphylococcus species were the most common bacteria found. Conclusion: Glucose meter strips should be recognized as a source of bacterial contamination that could be behind serious hospital acquired infections. The hospital infection control team should adopt proper measures to implement protocols for glucose meter cleaning and glucose strips handling. PMID:27570855

  13. Single-well reactive tracer test and stable isotope analysis for determination of microbial activity in a fast hydrocarbon-contaminated aquifer

    International Nuclear Information System (INIS)

    Burbery, L.; Cassiani, G.; Andreotti, G.; Ricchiuto, T.; Semple, K.T.

    2004-01-01

    Single-well reactive tracer tests, such as the push-pull test are useful tools for characterising in-situ bioattenuation processes in contaminated aquifers. However, the analytical models that are used to interpret push-pull data may be over-simplified, and potentially overlook important processes responsible for the frequent discrepancy between predicted and observed results obtained from push-pull tests. In this study, the limitations underlying the push-pull test methodology were investigated and were supported with results from a push-pull test conducted in a sulphate-reducing aquifer contaminated by crude oil. Poor ( 20% mass recoveries were achieved. Push-pull test data collected from sulphate-reducing aquifers indicate that the assumption of a well-mixed batch reactor system is incorrect and that reaction rates obtained from push-pull tests in such systems may be affected by the extraction regime implemented. Evidence of microbial respiration of the reactive tracer was provided by stable sulphur isotope analysis, from which an isotope fractionation factor of +9.9±8.1%o was estimated. The stable isotope data support the argument that reaction rates calculated using push-pull tests are not uniformly distributed in space and time and are likely to be influenced by heterogeneities in the flow field. - Reaction rates calculated by push-pull tests are not uniformly distributed in time and space

  14. Contamination by Helicobacter pylori measured by the 13C-urea-breast-test and nutritional status of children with chronic diarrhoea syndrome in Havana city

    International Nuclear Information System (INIS)

    Cabrera, A.; Hernandez-Triana, M.; Sanchez, M.; Herrera, X.; Pawong, M.; Moreno, R.; Reyes, D.; Serrano, G.; Diaz, M.E.; Valencia, M.

    2000-01-01

    Diarrhoea morbidity shows a slow increasing tendency during the last 10 years in Cuba. In young children the compromise of the gastric acid barrier after a chronic infection with Helicobacter pylori is discussed in pathogenic relation to gastritis, duodenal ulcer chronic diarrhoea, short stature, malabsorption of the B-complex vitamins and malnutrition. The Hp contamination level of the population of the developing world is estimated to be considerably high. Endoscopic studies carried out in Cuban subjects with upper gastrointestinal symptoms show contamination values of 60 to 100%. The current treatment of chronic diarrhoea does not include the elimination of Hp. Cuban children with upper gastrointestinal symptoms show contamination values of more than 60%. There are not available data on the contamination level in apparently healthy Cuban children or those with chronic diarrhoea. In March-April 2000 the prevalence of Hp infection measured in serum by chromatographic immunoassay for detection of Hp IgG antibodies was found to be 94% in 20 infants and young children with persistent chronic diarrhoea and 100% in 11 apparently healthy children in Havana City. Children with diarrhoea showed a more evident affection of their nutritional status and a higher percentage of positive personal or familiar history of parasitism, giardiasis, gastritis, ulcer stomatitis and glositis. The validity of the immunological tests in infants is discussed from the point of view of the antibody transference with breast milk. In a sample of 16 different children studied by the 13 C-Urea-Breath-Test the contamination level was 50% of the children not affected by diarrhoea and only one of the 6 children with diarrhoea showed positive values. This research contract proposes the study of contamination with Hp in Cuban children older than 2 years of age affected by chronic diarrhoea using the 13 C-Urea Breath Test and serological tests for detection of anti-Hp IgG antibodies. Their nutritional

  15. Identification of fecal contamination sources in water using host-associated markers.

    Science.gov (United States)

    Krentz, Corinne A; Prystajecky, Natalie; Isaac-Renton, Judith

    2013-03-01

    In British Columbia, Canada, drinking water is tested for total coliforms and Escherichia coli, but there is currently no routine follow-up testing to investigate fecal contamination sources in samples that test positive for indicator bacteria. Reliable microbial source tracking (MST) tools to rapidly test water samples for multiple fecal contamination markers simultaneously are currently lacking. The objectives of this study were (i) to develop a qualitative MST tool to identify fecal contamination from different host groups, and (ii) to evaluate the MST tool using water samples with evidence of fecal contamination. Singleplex and multiplex polymerase chain reaction (PCR) were used to test (i) water from polluted sites and (ii) raw and drinking water samples for presence of bacterial genetic markers associated with feces from humans, cattle, seagulls, pigs, chickens, and geese. The multiplex MST assay correctly identified suspected contamination sources in contaminated waterways, demonstrating that this test may have utility for heavily contaminated sites. Most raw and drinking water samples analyzed using singleplex PCR contained at least one host-associated marker. Singleplex PCR was capable of detecting host-associated markers in small sample volumes and is therefore a promising tool to further analyze water samples submitted for routine testing and provide information useful for water quality management.

  16. Determination of the external contamination and cross-contamination by cytotoxic drugs on the surfaces of vials available on the Swiss market.

    Science.gov (United States)

    Fleury-Souverain, Sandrine; Nussbaumer, Susanne; Mattiuzzo, Marc; Bonnabry, Pascal

    2014-04-01

    The external contamination and cross-contamination by cytotoxic drugs on the surface (outside and septum) of 133 vials from various manufacturers and available on the Swiss market were evaluated. All of the tested vials contained one of the following active ingredients: cyclophosphamide, cytarabine, doxorubicin, epirubicin, etoposide phosphate, gemcitabine, ifosfamide, irinotecan, methotrexate or vincristine. The validated wiping liquid chromatography-mass spectrometry method used in this study allowed for the simultaneous determination of these 10 cytotoxic drugs in less than 30 min. External contamination by cytotoxic drugs was detected on 63% of tested vials (outside and septum). The highest contamination level was observed on etoposide phosphate vials with 1896.66 ng of active ingredient on the outside of the vial. Approximately 20% of the contaminated vials had greater than 10 ng of cytotoxic drugs. Chemical contamination on the septum was detected on 38% of the vials. No contamination or very low levels of cytotoxic drugs, less than 1 ng per vial, were detected on the vials protected by plastic shrink-wrap. Traces of cytotoxic drugs different from the active ingredient were detected on 35% of the tested vials. Handling cytotoxic vials with gloves and having a procedure for the decontamination of vials are of the utmost importance for reducing exposure to cytotoxic drugs. Moreover, manufacturers must improve their procedures to provide products free from any contamination.

  17. Comparison of five bioassay techniques for assessing sediment-bound contaminants

    OpenAIRE

    Ahlf, Wolfgang; Calmano, Wolfgang; Erhard, Judith; Förstner, Ulrich

    1989-01-01

    Biological response could not be predicted based on chemical concentration of the sediment contaminants. Bioassays integrate the response of test organisms to contaminants and nutrients. Comparative results of five acute bioassays indicated that Neubauer phytoassay was the most sensitive. The mircobial biomass and algal growth tests indicated a response to the availability of contaminants and nutrients. These results suggest the usefulness of a diversity of bioassays in toxicity testing of se...

  18. The tolerance efficiency of Panicum maximum and Helianthus annuus in TNT-contaminated soil and nZVI-contaminated soil.

    Science.gov (United States)

    Jiamjitrpanich, Waraporn; Parkpian, Preeda; Polprasert, Chongrak; Laurent, François; Kosanlavit, Rachain

    2012-01-01

    This study was designed to compare the initial method for phytoremediation involving germination and transplantation. The study was also to determine the tolerance efficiency of Panicum maximum (Purple guinea grass) and Helianthus annuus (Sunflower) in TNT-contaminated soil and nZVI-contaminated soil. It was found that the transplantation of Panicum maximum and Helianthus annuus was more suitable than germination as the initiate method of nano-phytoremediation potting test. The study also showed that Panicum maximum was more tolerance than Helianthus annuus in TNT and nZVI-contaminated soil. Therefore, Panicum maximum in the transplantation method should be selected as a hyperaccumulated plant for nano-phytoremediation potting tests. Maximum tolerance dosage of Panicum maximum to TNT-concentration soil was 320 mg/kg and nZVI-contaminated soil was 1000 mg/kg in the transplantation method.

  19. The toxicity of oil-contaminated muskeg following biodegradation

    International Nuclear Information System (INIS)

    Farwell, A.; Kelly-Hooper, F.; McAlear, J.; Sinnesael, K.; Dixon, D.

    2009-01-01

    The current environmental criteria for the maximum allowable levels of hydrocarbons resulting from an oil spill assume that all detectable hydrocarbons are petroleum hydrocarbons (PHC) and do not account for naturally-occurring biogenic hydrocarbons (BHC). As such, some soils may be wrongfully assessed as being PHC contaminated. A false identification could lead to unnecessary and costly bioremediation that is potentially disruptive to functioning ecosystems. This study is part of a larger project to differentiate between natural and petroleum F3 hydrocarbons in muskeg material that has been impacted by an oil spill. The toxicity of oil-contaminated muskeg was examined following biodegradation in laboratory microcosms. Preliminary acute toxicity tests using locally purchased Sphagnum peat moss contaminated with Federated Crude oil had no effect on the survival of earthworms (Eisenia andrei), but springtails (Orthonychiurus folsomi) were more sensitive. Earthworm and springtail reproduction bioassays and a Northern wheatgrass (Elymus lanceolatus) growth bioassay was used to test the crude-oil-contaminated peat. All 3 test species will be used to test for reduced toxicity following biodegradation of Federated Crude oil-contaminated muskeg from northern Alberta under simulated conditions.

  20. The toxicity of oil-contaminated muskeg following biodegradation

    Energy Technology Data Exchange (ETDEWEB)

    Farwell, A.; Kelly-Hooper, F.; McAlear, J.; Sinnesael, K.; Dixon, D. [Waterloo Univ., Waterloo, ON (Canada)

    2009-07-01

    The current environmental criteria for the maximum allowable levels of hydrocarbons resulting from an oil spill assume that all detectable hydrocarbons are petroleum hydrocarbons (PHC) and do not account for naturally-occurring biogenic hydrocarbons (BHC). As such, some soils may be wrongfully assessed as being PHC contaminated. A false identification could lead to unnecessary and costly bioremediation that is potentially disruptive to functioning ecosystems. This study is part of a larger project to differentiate between natural and petroleum F3 hydrocarbons in muskeg material that has been impacted by an oil spill. The toxicity of oil-contaminated muskeg was examined following biodegradation in laboratory microcosms. Preliminary acute toxicity tests using locally purchased Sphagnum peat moss contaminated with Federated Crude oil had no effect on the survival of earthworms (Eisenia andrei), but springtails (Orthonychiurus folsomi) were more sensitive. Earthworm and springtail reproduction bioassays and a Northern wheatgrass (Elymus lanceolatus) growth bioassay was used to test the crude-oil-contaminated peat. All 3 test species will be used to test for reduced toxicity following biodegradation of Federated Crude oil-contaminated muskeg from northern Alberta under simulated conditions.

  1. Toxicity of sediments potentially contaminated by coal mining and natural gas extraction to unionid mussels and commonly tested benthic invertebrates

    Science.gov (United States)

    Wang, Ning; Ingersoll, Christopher G.; Kunz, James L.; Brumbaugh, William G.; Kane, Cindy M.; Evans, R. Brian; Alexander, Steven; Walker, Craig; Bakaletz, Steve

    2013-01-01

    Sediment toxicity tests were conducted to assess potential effects of contaminants associated with coal mining or natural gas extraction activities in the upper Tennessee River basin and eastern Cumberland River basin in the United States. Test species included two unionid mussels (rainbow mussel, Villosa iris, and wavy-rayed lampmussel, Lampsilis fasciola, 28-d exposures), and the commonly tested amphipod, Hyalella azteca (28-d exposure) and midge, Chironomus dilutus (10-d exposure). Sediments were collected from seven test sites with mussel communities classified as impacted and in proximity to coal mining or gas extraction activities, and from five reference sites with mussel communities classified as not impacted and no or limited coal mining or gas extraction activities. Additional samples were collected from six test sites potentially with high concentrations of polycyclic aromatic hydrocarbons (PAHs) and from a test site contaminated by a coal ash spill. Mean survival, length, or biomass of one or more test species was reduced in 10 of 14 test samples (71%) from impacted areas relative to the response of organisms in the five reference samples. A higher proportion of samples was classified as toxic to mussels (63% for rainbow mussels, 50% for wavy-rayed lampmussels) compared with amphipods (38%) or midge (38%). Concentrations of total recoverable metals and total PAHs in sediments did not exceed effects-based probable effect concentrations (PECs). However, the survival, length, or biomasses of the mussels were reduced significantly with increasing PEC quotients for metals and for total PAHs, or with increasing sum equilibrium-partitioning sediment benchmark toxic units for PAHs. The growth of the rainbow mussel also significantly decreased with increasing concentrations of a major anion (chloride) and major cations (calcium and magnesium) in sediment pore water. Results of the present study indicated that (1) the findings from laboratory tests were generally

  2. Ranking nano-enabled hybrid media for simultaneous removal of contaminants with different chemistries: Pseudo-equilibrium sorption tests versus column tests.

    Science.gov (United States)

    Custodio, Tomas; Garcia, Jose; Markovski, Jasmina; McKay Gifford, James; Hristovski, Kiril D; Olson, Larry W

    2017-12-15

    The underlying hypothesis of this study was that pseudo-equilibrium and column testing conditions would provide the same sorbent ranking trends although the values of sorbents' performance descriptors (e.g. sorption capacity) may vary because of different kinetics and competition effects induced by the two testing approaches. To address this hypothesis, nano-enabled hybrid media were fabricated and its removal performances were assessed for two model contaminants under multi-point batch pseudo-equilibrium and continuous-flow conditions. Calculation of simultaneous removal capacity indices (SRC) demonstrated that the more resource demanding continuous-flow tests are able to generate the same performance rankings as the ones obtained by conducing the simpler pseudo-equilibrium tests. Furthermore, continuous overlap between the 98% confidence boundaries for each SRC index trend, not only validated the hypothesis that both testing conditions provide the same ranking trends, but also pointed that SRC indices are statistically the same for each media, regardless of employed method. In scenarios where rapid screening of new media is required to obtain the best performing synthesis formulation, use of pseudo-equilibrium tests proved to be reliable. Considering that kinetics induced effects on sorption capacity must not be neglected, more resource demanding column test could be conducted only with the top performing media that exhibit the highest sorption capacity. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Fluorescence hyper-spectral imaging to detecting faecal contamination on fresh tomatoes

    Directory of Open Access Journals (Sweden)

    Roberto Romaniello

    2016-03-01

    Full Text Available Faecal contamination of fresh fruits represents a severe danger for human health. Thus some techniques based on microbiological testing were developed to individuate faecal contaminants but those tests do not results efficient because their non-applicability on overall vegetable unity. In this work a methodology based on hyper-spectral fluorescence imaging was developed and tested to detecting faecal contamination on fresh tomatoes. Two image-processing methods were performed to maximise the contrast between the faecal contaminant and tomatoes skin: principal component analysis and band image ratio (BRI. The BRI method allows classifying correctly 70% of contaminated area, with no false-positives in all examined cases. Thus, the developed methodology can be employed for a fast and effective detection of faecal contamination on fresh tomatoes.

  4. Application of multiple tracers (SF6 and chloride) to identify the transport by characteristics of contaminant at two separate contaminated sites

    Science.gov (United States)

    Lee, K. K.; Lee, S. S.; Kim, H. H.; Koh, E. H.; Kim, M. O.; Lee, K.; Kim, H. J.

    2016-12-01

    Multiple tracers were applied for source and pathway detection at two different sites. CO2 gas injected in the subsurface for a shallow-depth CO2 injection and leak test can be regarded as a potential contaminant source. Therefore, it is necessary to identify the migration pattern of CO2 gas. Also, at a DNAPL contaminated site, it is important to figure out the characteristics of plume evolution from the source zone. In this study, multiple tracers (SF6 and chloride) were used to evaluate the applicability of volatile and non-volatile tracers and to identify the characteristics of contaminant transport at each CO2 injection and leak test site and DNAPL contaminated site. Firstly, at the CO2 test site, multiple tracers were used to perform the single well push-drift-pull tracer test at total 3 specific depth zones. As results of tests, volatile and non-volatile tracers showed different mass recovery percentage. Most of chloride mass was recovered but less than half of SF6 mass was recovered due to volatile property. This means that only gaseous SF6 leak out to unsaturated zone. However, breakthrough curves of both tracers indicated similar peak time, effective porosity, and regional groundwater velocity. Also, at both contaminated sites, natural gradient tracer tests were performed with multiple tracers. With the results of natural gradient tracer test, it was possible to confirm the applicability of multiple tracers and to understand the contaminant transport in highly heterogeneous aquifer systems through the long-term monitoring of tracers. Acknowledgement: financial support was provided by the R&D Project on Environmental Management of Geologic CO2 Storage)" from the KEITI (Project Number: 2014001810003) and Korea Ministry of Environment as "The GAIA project (2014000540010)".

  5. Waste management of actinide contaminated soil

    International Nuclear Information System (INIS)

    Navratil, J.D.; Thompson, G.H.; Kochen, R.L.

    1978-01-01

    Waste management processes have been developed to reduce the volume of Rocky Flats soil contaminated with plutonium and americium and to prepare the contaminated fraction for terminal storage. The primary process consists of wet-screening. The secondary process uses attrition scrubbing and wet screening with additives. The tertiary process involves volume reduction of the contaminated fraction by calcination, or fixation by conversion to glass. The results of laboratory scale testing of the processes are described

  6. 9 CFR 113.28 - Detection of mycoplasma contamination.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Detection of mycoplasma contamination... REQUIREMENTS Standard Procedures § 113.28 Detection of mycoplasma contamination. The heart infusion test, using... for mycoplasma contamination is prescribed in an applicable Standard Requirement or in the filed...

  7. Contamination by Helicobacter pylori measured by the {sup 13}C-urea-breast-test and nutritional status of children with chronic diarrhoea syndrome in Havana city

    Energy Technology Data Exchange (ETDEWEB)

    Cabrera, A; Hernandez-Triana, M; Sanchez, M; Herrera, X; Pawong, M; Moreno, R; Reyes, D; Serrano, G; Diaz, M E [Institute of Nutrition and Food Hygiene, Department of Biochemistry and Physiology, Havana (Cuba); Valencia, M [Centro de Investigacion en Alimentacion y Desarrollo, Department of Human Nutrition, Hermosillo, Sonora (Mexico)

    2000-07-01

    Diarrhoea morbidity shows a slow increasing tendency during the last 10 years in Cuba. In young children the compromise of the gastric acid barrier after a chronic infection with Helicobacter pylori is discussed in pathogenic relation to gastritis, duodenal ulcer chronic diarrhoea, short stature, malabsorption of the B-complex vitamins and malnutrition. The Hp contamination level of the population of the developing world is estimated to be considerably high. Endoscopic studies carried out in Cuban subjects with upper gastrointestinal symptoms show contamination values of 60 to 100%. The current treatment of chronic diarrhoea does not include the elimination of Hp. Cuban children with upper gastrointestinal symptoms show contamination values of more than 60%. There are not available data on the contamination level in apparently healthy Cuban children or those with chronic diarrhoea. In March-April 2000 the prevalence of Hp infection measured in serum by chromatographic immunoassay for detection of Hp IgG antibodies was found to be 94% in 20 infants and young children with persistent chronic diarrhoea and 100% in 11 apparently healthy children in Havana City. Children with diarrhoea showed a more evident affection of their nutritional status and a higher percentage of positive personal or familiar history of parasitism, giardiasis, gastritis, ulcer stomatitis and glositis. The validity of the immunological tests in infants is discussed from the point of view of the antibody transference with breast milk. In a sample of 16 different children studied by the {sup 13}C-Urea-Breath-Test the contamination level was 50% of the children not affected by diarrhoea and only one of the 6 children with diarrhoea showed positive values. This research contract proposes the study of contamination with Hp in Cuban children older than 2 years of age affected by chronic diarrhoea using the {sup 13}C-Urea Breath Test and serological tests for detection of anti-Hp IgG antibodies. Their

  8. Examining Lead Exposures in California through State-Issued Health Alerts for Food Contamination and an Exposure-Based Candy Testing Program.

    Science.gov (United States)

    Handley, Margaret A; Nelson, Kali; Sanford, Eric; Clarity, Cassidy; Emmons-Bell, Sophia; Gorukanti, Anuhandra; Kennelly, Patrick

    2017-10-26

    In California, the annual number of children under age 6 y of age with blood lead levels (BLL) ≥10μg/dL is estimated at over 1,000 cases, and up to 10,000 cases when BLL between 4.5 and 9.5 μg/dL are included. State-issued health alerts for food contamination provide one strategy for tracking sources of food-related lead exposures. As well, California passed legislation in 2006 for the Food and Drug Branch (FDB) of the state health department to test and identify lead in candy. This report presents health alert data from California over a 14-y period, compares data before and after the candy testing program began, and examines country of origin, ZIP code data, and time from candy testing to release of health alerts for lead-contaminated candies for 2011-2012. After 2007, health alerts issued for lead in candy and food increased significantly. Analysis of candy-testing data indicated that multiple counties and ZIP codes were affected. Seventeen candies with high lead concentrations were identified, resulting in rapid dissemination (food and candy testing programs provides an opportunity to identify and immediately act to remove nonpaint sources of lead affecting children. https://doi.org/10.1289/EHP2582.

  9. Terrestrial Eco-Toxicological Tests as Screening Tool to Assess Soil Contamination in Krompachy Area

    Science.gov (United States)

    Ol'ga, Šestinová; Findoráková, Lenka; Hančuľák, Jozef; Fedorová, Erika; Tomislav, Špaldon

    2016-10-01

    In this study, we present screening tool of heavy metal inputs to agricultural and permanent grass vegetation of the soils in Krompachy. This study is devoted to Ecotoxicity tests, Terrestrial Plant Test (modification of OECD 208, Phytotoxkit microbiotest on Sinapis Alba) and chronic tests of Earthworm (Dendrobaena veneta, modification of OECD Guidelines for the testing of chemicals 317, Bioaccumulation in Terrestrial Oligochaetes) as practical and sensitive screening method for assessing the effects of heavy metals in Krompachy soils. The total Cu, Zn, As, Pb and Hg concentrations and eco-toxicological tests of soils from the Krompachy area were determined of 4 sampling sites in 2015. An influence of the sampling sites distance from the copper smeltery on the absolutely concentrations of metals were recorded for copper, lead, zinc, arsenic and mercury. The highest concentrations of these metals were detected on the sampling sites up to 3 km from the copper smeltery. The samples of soil were used to assess of phytotoxic effect. Total mortality was established at earthworms using chronic toxicity test after 7 exposure days. The results of our study confirmed that no mortality was observed in any of the study soils. Based on the phytotoxicity testing, phytotoxic effects of the metals contaminated soils from the samples 3KR (7-9) S.alba seeds was observed.

  10. Basic radiological studies contamination control experiments

    International Nuclear Information System (INIS)

    Duce, S.W.; Winberg, M.R.; Freeman, A.L.

    1989-09-01

    This report describes the results of experiments relating to contamination control performed in support of the Environmental Restoration Programs Retrieval Project. During the years 1950 to 1970 waste contaminated with plutonium and other transuranic radionuclides was disposed of in shallow land-filled pits and trenches at the Idaho National Engineering Laboratory. Due to potential for migration of radionuclides to an existing aquifer the feasibility of retrieving and repackaging the waste for placement in a final repository is being examined as part of a retrieval project. Contamination control experiments were conducted to determine expected respirable and nonrespirable plutonium contaminated dust fractions and the effectiveness of various dust suppression techniques. Three soil types were tested to determine respirable fractions: Rocky Flats Plant generic soil, Radioactive Waste Management Complex generic soil, and a 1:1 blend of the two soil types. Overall, the average respirable fraction of airborne dust was 5.4% by weight. Three contamination control techniques were studied: soil fixative sprays, misting agents, and dust suppression agents. All of the tested agents proved to be effective in reducing dust in the air. Details of product performance and recommended usage are discussed

  11. Radiation protection. Clothing for protection against radioactive contamination. Design, selection, testing and use

    International Nuclear Information System (INIS)

    1987-09-01

    The present Standard gives the characteristics of clothing protecting the wearer against radioactive contamination brought about by contact with liquid or solid substances or by atmospheric pollutants, such as solid particles, mist, gases or vapours. The Standard applies to two types of clothing: firstly, ventilated-pressurized garments; secondly, unventilated-unpressurized garments. A test method according to which any new type of garment can be assigned a protection factor that makes it easier for the user to make a choice is described. The report also gives methods for measuring leak-tightness and air supply flow rates of ventilated-pressurized garments. For guidance purposes only, recommendations for choosing protective clothing are given. 5 figs, 2 tabs [fr

  12. Technology status report: Transuranic contamination control at INEL

    International Nuclear Information System (INIS)

    Loomis, G.G.

    1991-09-01

    This report summarizes proposed FY-92 work at the Idaho National Engineering Laboratory (INEL) in the field of contamination control during transuranic waste handling operations. The proposed work is both applied research and demonstration testing. The INEL needs for contamination control applied research and demonstration testing are listed along with a description of past accomplishments. The INEL proposal is compared to other proposals for contamination control work that are under consideration for funding by the Department of Energy. Benefits of this work and impacts of not sponsoring this work are also given. 21 refs

  13. Hand and foot contamination monitor

    International Nuclear Information System (INIS)

    Jakati, R.K.; Kaptral, R.S.; Ananthkrishnan, T.S.; Pansare, M.G.

    1989-01-01

    In order to make quick measurements of beta and gamma contaminations on hands and feet of personnel working in radioactive environments, hand and foot contamination monitors are widely used. This paper describes such a monitor system designed with Intel 8085 based microcomputer. The monitoring and warning system is designed to perform measurement of activity spread over surface of hands and soles of shoes or feet. Even though the system has many features to aid testing and maintainance operation, it is easy to use for unskilled persons. In order to check the contamination, the person stands on platform and inserts both his hands into detector assemblies thereby actuating the sensing switches. After a preset interval, annunciation of clean or contaminated status is declared by the system. (author)

  14. The influences of contamination during lamination on the properties of composite materials

    Energy Technology Data Exchange (ETDEWEB)

    Hall Beng, G.M. (Univ. of Portsmouth, School of Systems Engineering, Portsmouth (United Kingdom)); Mason, S.E. (Univ. of Portsmouth, School of Systems Engineering, Portsmouth (United Kingdom))

    1993-11-01

    The quality of a fibrous composite laminate can be largely attributed to the laminating process. It is therefore important to control parameters which will ultimately affect the desired quality of the laminate. Although several composite manufacturing organisations have installed clean room facilities with the hope of controlling potential contaminants, which may be detrimental to the process, the unavoidable reductions in productivity, coupled with the initial capital and maintenance costs make it an expensive solution to an unquantified problem. This study investigates the influences of contamination on structural fibre reinforced composites. Initial testing has involved contaminating Carbon/Epoxy (Fiberite 7714B) prepregs on a gross level. Contaminants have been selected on a tactile level in order to be as closely representative of situations likely to be encountered in the laminating process. The research has concentrated on airborne particulates, including fibres, condensation and humidity. Modes of contamination have been proposed for each, and suitable test methods selected to verify the modes. Test methods include the sort beam shear test (interlaminar shear strength), double cantilever beam test (interlaminar fracture data) and tensile tests. Such high levels of contamination enables the identification of those contaminants that are most detrimental to final laminate quality. Strategic reduction in the contamination levels of those identified will enable the clean room operating level to be sought. (orig.).

  15. The influences of contamination during lamination on the properties of composite materials

    International Nuclear Information System (INIS)

    Hall Beng, G.M.; Mason, S.E.

    1993-01-01

    The quality of a fibrous composite laminate can be largely attributed to the laminating process. It is therefore important to control parameters which will ultimately affect the desired quality of the laminate. Although several composite manufacturing organisations have installed clean room facilities with the hope of controlling potential contaminants, which may be detrimental to the process, the unavoidable reductions in productivity, coupled with the initial capital and maintenance costs make it an expensive solution to an unquantified problem. This study investigates the influences of contamination on structural fibre reinforced composites. Initial testing has involved contaminating Carbon/Epoxy (Fiberite 7714B) prepregs on a gross level. Contaminants have been selected on a tactile level in order to be as closely representative of situations likely to be encountered in the laminating process. The research has concentrated on airborne particulates, including fibres, condensation and humidity. Modes of contamination have been proposed for each, and suitable test methods selected to verify the modes. Test methods include the sort beam shear test (interlaminar shear strength), double cantilever beam test (interlaminar fracture data) and tensile tests. Such high levels of contamination enables the identification of those contaminants that are most detrimental to final laminate quality. Strategic reduction in the contamination levels of those identified will enable the clean room operating level to be sought. (orig.)

  16. Bonding of radioactive contamination. IV. Effect of surface finish

    International Nuclear Information System (INIS)

    Rankin, W.N.

    1983-01-01

    The mechanisms by which radioactive contamination would be bonded to a DWPF canister are being investigated. Previous investigations in this series have examined the effects of temperature, oxidation before contamination, and atmosphere composition control on the bonding of contamination. This memorandum describes the results of tests to determine the effect of special surface finishes on the bonding of contamination to waste glass canisters. Surface pretreatments which produce smoother canister surfaces actually cause radioactive contamination to be more tightly bonded to the metal surface than on an untreated surface. Based on the results of these tests it is recommended that the canister surface finish be specified as having a bright cold rolled mill finish equivalent to ASTM No. 2B. 7 references, 3 figures, 3 tables

  17. Reconditioning contaminated gravel

    International Nuclear Information System (INIS)

    Walsh, H.; Bowers, J.S.; Cadwell, K.

    1995-02-01

    Lawrence Livermore National Laboratory (LLNL) has developed a portable screening system that will recondition radioactively contaminated gravel in the field. The separation technique employed by this system removes dirt, contaminated debris, and other fine particles from gravel. At LLNL, gravel is used in conjunction with the experimental testing of explosives to reduce shock wave propagation. The gravel surrounds the experimental device and buffers the energy generated from the explosion. During an explosion, some of the gravel is broken down into small particles and mixed with contaminants. Contaminants in the used gravel originate from metal sheathing and other parts comprising, the experimental device. These contaminants may consist of radionuclides and metals that are considered hazardous by the State of California when disposed. This paper describes the process that conveys contaminated material into the screener system, sprays the material with recycled water or other mild cleaning chemicals, and separates particles based on size. Particles greater than a specified size are discharged out of the screener separator and recycled back into use, thereby reducing the amount of mixed waste generated and minimizing the need for new gravel. The fines or silt are flushed out of the separator with the water and are removed from the water and consolidated into a drum with the use of a hydrocyclone separator and drum decant system. Because the water in the spray system is recycled, minimal makeup water is needed. The system monitors pH and total dissolved solids

  18. Underwater Coatings for Contamination Control

    International Nuclear Information System (INIS)

    Julia L. Tripp; Kip Archibald; Ann-Marie Phillips; Joseph Campbell

    2004-01-01

    The Idaho National Engineering and Environmental Laboratory (INEEL) is deactivating several fuel storage basins. Airborne contamination is a concern when the sides of the basins are exposed and allowed to dry during water removal. One way of controlling this airborne contamination is to fix the contamination in place while the pool walls are still submerged. There are many underwater coatings available on the market that are used in marine, naval and other applications. A series of tests were run to determine whether the candidate underwater fixatives are easily applied and adhere well to the substrates (pool wall materials) found in INEEL fuel pools. The four pools considered included (1) Test Area North (TAN-607) with epoxy painted concrete walls; (2) Idaho Nuclear Technology and Engineering Center (INTEC) (CPP-603) with bare concrete walls; (3) Materials Test Reactor (MTR) Canal with stainless steel lined concrete walls; and (4) Power Burst Facility (PBF-620) with stainless steel lined concrete walls on the bottom and epoxy painted carbon steel lined walls on the upper portions. Therefore, the four materials chosen for testing included bare concrete, epoxy painted concrete, epoxy painted carbon steel, and stainless steel. The typical water temperature of the pools varies from 55 F to 80 F dependent on the pool and the season. These tests were done at room temperature. The following criteria were used during this evaluation. The underwater coating must: (1) Be easy to apply; (2) Adhere well to the four surfaces of interest; (3) Not change or have a negative impact on water chemistry or clarity; (4) Not be hazardous in final applied form; and (5) Be proven in other underwater applications. In addition, it is desirable for the coating to have a high pigment or high cross-link density to prevent radiation from penetrating. This paper will detail the testing completed and the test results. A proprietary two-part, underwater epoxy owned by S. G. Pinney and Associates

  19. Rehabilitation of radioactive contaminated forests

    International Nuclear Information System (INIS)

    Panfilov, A.V.; Uspenskaya, E.Ju.

    2002-01-01

    As a result of radiation accidents and nuclear-weapon tests at the territory of the former USSR a part of the Forest Fund of 23 subjects of the Russian Federation has been contaminated by radionuclides. The contaminated forests, which are included in a structure of more than 130 forest management units (leskhozes) and more then 330 local forest management units, as a rule, are located in highly inhabited regions with traditionally intensive forestry management and high level of forest resources use. To provide radiologically safe forest management in the contaminated areas, the Federal Forest Service has developed and validated a special system of countermeasures. Use of this system makes it possible to diminish significantly the dose to personnel, to exclude the use of forest products with contamination exceeding radiological standards and to provide protection of the forest as a biogeochemical barrier to radionuclide migration from contaminated areas to human habitat. (author)

  20. Photocatalytic remediation of contaminated solids

    Energy Technology Data Exchange (ETDEWEB)

    Chiarenzelli, J R; Scrudato, R J [State Univ. of New York, Oswego, NY (United States). Research Center

    1996-12-31

    Results of various experiments to utilize photocatalysis to photodegrade polychlorinated biphenyls (PCBs) and pesticide-contaminated sediments and soils in slurry suspensions, were discussed. The mechanism of the reaction, i. e. simultaneously bringing together the catalyst, contaminant and light through mixing or overturn of the material, was explained. Potential advantages of the method (on-site treatment, simultaneous degradation of multiple contaminants, low energy requirements, no emission of toxic effluents, reusable inert catalyst, no landfilling or future liability, etc.,) were reviewed. A pilot-scale test is planned for the near future to provide performance data needed for eventual commercialization. 8 refs.

  1. Environmental assessment of waste matrices contaminated with arsenic.

    Science.gov (United States)

    Sanchez, F; Garrabrants, A C; Vandecasteele, C; Moszkowicz, P; Kosson, D S

    2003-01-31

    The use of equilibrium-based and mass transfer-based leaching tests has been proposed to provide an integrated assessment of leaching processes from solid wastes. The objectives of the research presented here are to (i) validate this assessment approach for contaminated soils and cement-based matrices, (ii) evaluate the use of diffusion and coupled dissolution-diffusion models for estimating constituent release, and (iii) evaluate model parameterization using results from batch equilibrium leaching tests and physical characterization. The test matrices consisted of (i) a soil contaminated with arsenic from a pesticide production facility, (ii) the same soil subsequently treated by a Portland cement stabilization/solidification (S/S) process, and (iii) a synthetic cement-based matrix spiked with arsenic(III) oxide. Results indicated that a good assessment of contaminant release from contaminated soils and cement-based S/S treated wastes can be obtained by the integrated use of equilibrium-based and mass transfer-based leaching tests in conjunction with the appropriate release model. During the time scale of laboratory testing, the release of arsenic from the contaminated soil matrix was governed by diffusion and the solubility of arsenic in the pore solution while the release of arsenic from the cement-based matrices was mainly controlled by solubilization at the interface between the matrix and the bulk leaching solution. In addition, results indicated that (i) estimation of the activity coefficient within the matrix pore water is necessary for accurate prediction of constituent release rates and (ii) inaccurate representation of the factors controlling release during laboratory testing can result in significant errors in release estimates.

  2. Plutonium contamination in the Maralinga Tjarutja lands

    International Nuclear Information System (INIS)

    Johnston, P.N.; Lokan, K.H.; Richardson, C.K.; Williams, G.A.

    1989-08-01

    Nuclear weapons trials conducted at Maralinga from 1960 to 1963 resulted in contamination of large areas of land with low levels of plutonium. Ground and aerial surveys and soil sampling conducted between 1984 and 1987 showed that this contamination extended beyond the boundaries of the area still controlled by the Commonwealth Government into the Maralinga Tjarutja lands. Levels of contamination beyond the boundaries of the former test range were found to be low, and were generally undetectable for all but the most sensitive measurement techniques. Soil sampling combined with long laboratory counting was initially used to define the trace levels but the contamination was found to be particulate with a surface density of particles too low for this to be a generally useful technique. The results are presented of in-situ gamma-ray spectrometry using a portable germanium (Ge) detector to measure contamination levels of plutonium to well below 1 kBq m -2 in the Maralinga Tjarutja lands to the north and north-west of the Maralinga test site. 8 refs., 10 figs., 10 tabs

  3. Mental contamination: The effects of religiosity.

    Science.gov (United States)

    Bilekli, Ilgun; Inozu, Mujgan

    2018-03-01

    Mental contamination, which occurs in the absence of contact with a contaminant, has a moral element. Previous studies evoked feelings of mental contamination via listening to a scenario, which described a non-consensual kiss. Since mental contamination has a moral element, we tested the effects of the level of religiosity on feelings of mental contamination and related variables in an experimental design. Female undergraduates of high religiosity (n = 48) and low religiosity (n = 44) were randomly assigned to listen to one of two audio recordings involving a consensual or non-consensual kiss from a man described as moral. Mental contamination feelings were evoked successfully in both groups. Effects of scenario condition and religiosity level were seen in mental contamination and related negative feelings. Participants who imagined a non-consensual kiss reported greatest feelings of mental contamination, and internal and external negative feelings. More importantly, high religiosity resulted in greater feelings of mental contamination, internal negative feelings, as well as urges to wash and actual washing behaviors. The current study was conducted on non-clinical Muslim females. This limits the generalization of the findings to the wider population. Mental contamination and related feelings can be seen in different forms at different levels of religiosity. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Space station contamination control study: Internal combustion, phase 1

    Science.gov (United States)

    Ruggeri, Robert T.

    1987-01-01

    Contamination inside Space Station modules was studied to determine the best methods of controlling contamination. The work was conducted in five tasks that identified existing contamination control requirements, analyzed contamination levels, developed outgassing specification for materials, wrote a contamination control plan, and evaluated current materials of offgassing tests used by NASA. It is concluded that current contamination control methods can be made to function on the Space Station for up to 1000 days, but that current methods are deficient for periods longer than about 1000 days.

  5. Testing of the KRIA Ionizing Water Treatment System for Waters Contaminated with Diesel, PCBs, and Nutrients (Nitrogen Forms)

    Science.gov (United States)

    2016-02-01

    1145. Medina, V. F. 2014. Evaluation of hydraulic fracturing ( fracking ) for potential impact for potential impact on waterways managed by the Army...with hydrofracturing ( fracking ), although these fluids contain a much broader range of potential contaminants that may require some additional...for establishing sanitation in third world countries. • The KRIA should be tested on solutions associated with fracking and on water bodies

  6. Testing of TSCA [Toxic Substances Control Act] incinerator for destruction of PCBs in uranium contaminated wastes

    International Nuclear Information System (INIS)

    Anderson, R.W.

    1987-01-01

    A Toxic Substances Control Act (TSCA) incinerator for environmentally safe destruction of PCBs and hazardous organic materials contaminated with low level radioactive wastes from seven DOE facilities has been constructed at the Oak Ridge Gaseous Diffusion Plant, and has undergone performance testing with PCB surrogates. The system incorporates state-of-the-art off-gas treatment, a highly instrumented kiln and secondary combustion chamber, and an inert atmosphere solids handling feed system. Release of organic during an upset event, which triggers opening of the secondary combustion chamber relief vent, will be prevented by maintaining excess oxygen in the kiln and a high temperature in the secondary combustion chamber with an operating burner. Mixtures of chlorinated benzenes used in performance testing to simulate destruction of PCB, worst case studies to satisfy regulatory concerns, and implications of performance test results will be discussed. 4 refs

  7. Contamination mechanisms of air basin with tritium in venues of underground nuclear explosions at the former Semipalatinsk test site.

    Science.gov (United States)

    Lyakhova, O N; Lukashenko, S N; Larionova, N V; Tur, Y S

    2012-11-01

    During the period of testing from 1945 to 1962 at the territory of Semipalatinsk test site (STS) within the Degelen Mountains in tunnels, 209 underground nuclear explosions were produced. Many of the tunnels have seasonal water seepage in the form of streams, through which tritium migrates from the underground nuclear explosion (UNE) venues towards the surface. The issue of tritium contamination occupies a special place in the radioactive contamination of the environment. In this paper we assess the level and distribution of tritium in the atmospheric air of ecosystems with water seepage at tunnels № 176 and № 177, located on "Degelen" site. There has been presented general nature of tritium distribution in the atmosphere relative to surface of a watercourse which has been contaminated with tritium. The basic mechanisms were studied for tritium distribution in the air of studied ecosystems, namely, the distribution of tritium in the systems: water-atmosphere, tunnel air-atmosphere, soil water-atmosphere, vegetation-atmosphere. An analytical calculation of tritium concentration in the atmosphere by the concentration of tritium in water has been performed. There has experimentally obtained the dependence for predictive assessment of tritium concentrations in air as a function of tritium concentration in one of the inlet sources such as water, tunnel air, soil water, vegetation, etc.. The paper also describes the general nature of tritium distribution in the air in the area "Degelen". Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Heavy metal accumulation in earthworms exposed to spatially variable soil contamination

    NARCIS (Netherlands)

    Marinussen, M.

    1997-01-01

    Ecotoxicity of contaminated soil is commonly tested in standard laboratory tests. Extrapolation of these data to the field scale is complicated due to considerable differences between conditions in laboratory tests and conditions in situ in contaminated soils. In this

  9. Contamination mechanisms of air basin with tritium in venues of underground nuclear explosions at the former Semipalatinsk test site

    International Nuclear Information System (INIS)

    Lyakhova, O.N.; Lukashenko, S.N.; Larionova, N.V.; Tur, Y.S.

    2012-01-01

    During the period of testing from 1945 to 1962 at the territory of Semipalatinsk test site (STS) within the Degelen Mountains in tunnels, 209 underground nuclear explosions were produced. Many of the tunnels have seasonal water seepage in the form of streams, through which tritium migrates from the underground nuclear explosion (UNE) venues towards the surface. The issue of tritium contamination occupies a special place in the radioactive contamination of the environment. In this paper we assess the level and distribution of tritium in the atmospheric air of ecosystems with water seepage at tunnels № 176 and № 177, located on “Degelen” site. There has been presented general nature of tritium distribution in the atmosphere relative to surface of a watercourse which has been contaminated with tritium. The basic mechanisms were studied for tritium distribution in the air of studied ecosystems, namely, the distribution of tritium in the systems: water–atmosphere, tunnel air–atmosphere, soil water–atmosphere, vegetation–atmosphere. An analytical calculation of tritium concentration in the atmosphere by the concentration of tritium in water has been performed. There has experimentally obtained the dependence for predictive assessment of tritium concentrations in air as a function of tritium concentration in one of the inlet sources such as water, tunnel air, soil water, vegetation, etc.. The paper also describes the general nature of tritium distribution in the air in the area “Degelen”. - Highlights: ► The basic mechanisms for tritium distribution in the air of nuclear testing sites were examined. ► We researched the distribution of tritium in the systems such as water–atmosphere, tunnel air–atmosphere, soil water–atmosphere and vegetation–atmosphere. ► An analytical calculation of tritium concentration in the atmosphere was performed. ► We experimentally obtained the dependence for predictive assessment of tritium concentrations in

  10. The enchytraeid reproduction test (ERT): A potentially quick and affordable tool for the assessment of metal contaminated soils in emerging economies.

    Science.gov (United States)

    Voua Otomo, Patricks; Wahl, Jurie; Maboeta, Mark S

    2013-11-01

    The enchytraeid reproduction test (ERT) was used to assess the ecotoxicity of selected mine tailings and agricultural soils from South Africa. The mine tailings had higher cumulative metal concentrations than agricultural soils. The most contaminated mine tailings significantly reduced the survival of the oligochaete Enchytraeus doerjesi whose reproduction was suppressed in all mine waste substrates. Because it reliably singled out the most contaminated substrate and was found easy to perform, we suggest that the ERT could be a quick and affordable tool for assigning intervention values for soil remediation in emerging economies such as South Africa.

  11. Evaluation of bacterial contamination of 'suya' at Nsukka, Enugu ...

    African Journals Online (AJOL)

    Three hundred and four (304) test samples in the course of "suya" meat processing and after display for sale were collected from seven centers for bacteria load screening. The result showed that all the samples tested were contaminated to varying degrees. The level of contamination however was highest in the fresh meat ...

  12. Geotechnical properties of crude oil contaminated sand

    International Nuclear Information System (INIS)

    Puri, V.K.; Das, B.M.; Cook, E.E.; Shin, E.C.

    1994-01-01

    Contamination of soil due to an oil spill influences its subsequent engineering behavior. An investigation was conducted to study the effect of crude oil contamination on compaction characteristics, shear strength, one-dimensional compression, and coefficient of permeability. Water permeability was also determined by using commercial grade motor oils as contaminants. The test results indicate that the compaction characteristics are influenced by oil contamination. The angle of internal friction of sand (based on total stress condition) decreases due to presence of oil within the pore spaces in sand. One dimensional compression characteristics of sand are significantly influenced by oil contamination resulting in a decrease in the value of constrained modulus with increase in the degree of oil contamination compared to the case of dry sand. Water permeability was observed to be a function of the initial viscosity and the degree of saturation due to the contaminating oil

  13. Doublet tracer tests to determine the contaminant flushing properties of a municipal solid waste landfill.

    Science.gov (United States)

    Woodman, N D; Rees-White, T C; Beaven, R P; Stringfellow, A M; Barker, J A

    2017-08-01

    This paper describes a programme of research investigating horizontal fluid flow and solute transport through saturated municipal solid waste (MSW) landfill. The purpose is to inform engineering strategies for future contaminant flushing. Solute transport between injection/abstraction well pairs (doublets) is investigated using three tracers over five separate tests at well separations between 5m and 20m. Two inorganic tracers (lithium and bromide) were used, plus the fluorescent dye tracer, rhodamine-WT. There was no evidence for persistent preferential horizons or pathways at the inter-well scale. The time for tracer movement to the abstraction wells varied with well spacing as predicted for a homogeneous isotropic continuum. The time for tracer movement to remote observation wells was also as expected. Mobile porosity was estimated as ~0.02 (~4% of total porosity). Good fits to the tracer breakthrough data were achieved using a dual-porosity model, with immobile regions characterised by block diffusion timescales in the range of about one to ten years. This implies that diffusional exchanges are likely to be very significant for engineering of whole-site contaminant flushing and possibly rate-limiting. Copyright © 2017. Published by Elsevier B.V.

  14. Corrective Action Decision Document/Closure Report for Corrective Action Unit 190: Contaminated Waste Sites, Nevada Test Site, Nevada, Revision 0

    International Nuclear Information System (INIS)

    Alfred Wickline

    2008-01-01

    This Corrective Action Decision Document/Closure Report has been prepared for Corrective Action Unit (CAU) 190, Contaminated Waste Sites, Nevada Test Site, Nevada, in accordance with the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy, Environmental Management; U.S. Department of Defense; and DOE, Legacy Management (1996, as amended January 2007). Corrective Action Unit 190 is comprised of the following four corrective action sites (CASs): (1) 11-02-01, Underground Centrifuge; (2) 11-02-02, Drain Lines and Outfall; (3) 11-59-01, Tweezer Facility Septic System; (4) 14-23-01, LTU-6 Test Area The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation for closure of CAU 190 with no further corrective action. To achieve this, corrective action investigation (CAI) activities were performed from March 21 through June 26, 2007. All CAI activities were conducted as set forth in the Corrective Action Investigation Plan for Corrective Action Unit 190: Contaminated Waste Sites, Nevada Test Site, Nevada (NNSA/NSO, 2006). The purpose of the CAI was to fulfill the following data needs as defined during the data quality objective process: (1) Determine whether contaminants of concern (COCs) are present. (2) If COCs are present, determine their nature and extent. (3) Provide sufficient information and data to complete appropriate corrective actions. The CAU 190 dataset from the investigation results was evaluated based on the data quality indicator parameters. This evaluation demonstrated the quality and acceptability of the dataset for use in fulfilling the data quality objective data needs

  15. Sodium citrate blood contamination by K2 -ethylenediaminetetraacetic acid (EDTA): impact on routine coagulation testing.

    Science.gov (United States)

    Lima-Oliveira, G; Salvagno, G L; Danese, E; Favaloro, E J; Guidi, G C; Lippi, G

    2015-06-01

    The potential cross-contamination of additives between primary blood tubes is a well-known problem during sample collection. The aim of this study was to assess the impact of citrated blood contamination with different amounts of dipotassium ethylenediaminetetraacetic (K2 EDTA blood) on activated partial thromboplastin time (APTT), prothrombin time (PT), and fibrinogen. Blood was collected from 15 ostensibly healthy volunteers into four 0.109 m citrate blood tubes followed by one K2 EDTA blood tube. The citrate tubes of each subject were pooled and divided in five aliquots. The whole blood of the K2 EDTA tube was then added in scalar amounts to autologous citrated blood aliquots, to obtain K2 EDTA contamination ranging from 0% to 43%, and thus mimic potential pre-analytical contamination. A statistically and clinically significant prolongation was observed for both APTT and PT between 29% and 43% K2 EDTA contamination, whereas the decrease of fibrinogen values became statistically and clinically significant at 43% K2 EDTA contamination. The results of this investigation show that contamination of citrated blood with as much as 29% of K2 EDTA blood generates a significant bias in results of routine clotting assays. This has serious implications for patient safety and management. © 2014 John Wiley & Sons Ltd.

  16. Role of subtyping in detecting Salmonella cross contamination in the laboratory.

    LENUS (Irish Health Repository)

    De Lappe, Niall

    2009-01-01

    BACKGROUND: With the exception of M. tuberculosis, little has been published on the problems of cross-contamination in bacteriology laboratories. We performed a retrospective analysis of subtyping data from the National Salmonella Reference Laboratory (Ireland) from 2000-2007 to identify likely incidents of laboratory cross contamination. METHODS: Serotyping and antimicrobial susceptibility testing was performed on all Salmonella isolates received in the NSRL. Phage typing was performed on all S. Typhimurium and S. Enteritidis isolates while multi-locus variance analysis (MLVA) was performed on selected S. Typhimurium isolates. Pulsed field gel electrophoresis (PFGE) using the PulseNet standard protocol was performed on selected isolates of various serovars. RESULTS: Twenty-three incidents involving fifty-six isolates were identified as likely to represent cross contamination. The probable sources of contamination identified were the laboratory positive control isolate (n = 13), other test isolates (n = 9) or proficiency test samples (n = 1). CONCLUSION: The scale of laboratory cross-contamination in bacteriology is most likely under recognized. Testing laboratories should be aware of the potential for cross-contamination, regularly review protocols to minimize its occurrence and consider it as a possibility when unexpected results are obtained.

  17. Multiple-tracer tests for contaminant transport process identification in saturated municipal solid waste

    International Nuclear Information System (INIS)

    Woodman, N.D.; Rees-White, T.C.; Stringfellow, A.M.; Beaven, R.P.; Hudson, A.P.

    2015-01-01

    Highlights: • Multiple tracers were applied to saturated MSW to test dual-porosity properties. • Lithium demonstrated to be non-conservative as a tracer. • 260 mm diameter column too small to test transport properties of MSW. • The classical advection-dispersion mode was rejected due to high dispersivity. • Characteristic diffusion times did not vary with the tracer. - Abstract: Two column tests were performed in conditions emulating vertical flow beneath the leachate table in a biologically active landfill to determine dominant transport mechanisms occurring in landfills. An improved understanding of contaminant transport process in wastes is required for developing better predictions about potential length of the long term aftercare of landfills, currently measured in timescales of centuries. Three tracers (lithium, bromide and deuterium) were used. Lithium did not behave conservatively. Given that lithium has been used extensively for tracing in landfill wastes, the tracer itself and the findings of previous tests which assume that it has behaved conservatively may need revisiting. The smaller column test could not be fitted with continuum models, probably because the volume of waste was below a representative elemental volume. Modelling compared advection-dispersion (AD), dual porosity (DP) and hybrid AD–DP models. Of these models, the DP model was found to be the most suitable. Although there is good evidence to suggest that diffusion is an important transport mechanism, the breakthrough curves of the different tracers did not differ from each other as would be predicted based on the free-water diffusion coefficients. This suggested that solute diffusion in wastes requires further study

  18. Multiple-tracer tests for contaminant transport process identification in saturated municipal solid waste

    Energy Technology Data Exchange (ETDEWEB)

    Woodman, N.D., E-mail: n.d.woodman@soton.ac.uk; Rees-White, T.C.; Stringfellow, A.M.; Beaven, R.P.; Hudson, A.P.

    2015-04-15

    Highlights: • Multiple tracers were applied to saturated MSW to test dual-porosity properties. • Lithium demonstrated to be non-conservative as a tracer. • 260 mm diameter column too small to test transport properties of MSW. • The classical advection-dispersion mode was rejected due to high dispersivity. • Characteristic diffusion times did not vary with the tracer. - Abstract: Two column tests were performed in conditions emulating vertical flow beneath the leachate table in a biologically active landfill to determine dominant transport mechanisms occurring in landfills. An improved understanding of contaminant transport process in wastes is required for developing better predictions about potential length of the long term aftercare of landfills, currently measured in timescales of centuries. Three tracers (lithium, bromide and deuterium) were used. Lithium did not behave conservatively. Given that lithium has been used extensively for tracing in landfill wastes, the tracer itself and the findings of previous tests which assume that it has behaved conservatively may need revisiting. The smaller column test could not be fitted with continuum models, probably because the volume of waste was below a representative elemental volume. Modelling compared advection-dispersion (AD), dual porosity (DP) and hybrid AD–DP models. Of these models, the DP model was found to be the most suitable. Although there is good evidence to suggest that diffusion is an important transport mechanism, the breakthrough curves of the different tracers did not differ from each other as would be predicted based on the free-water diffusion coefficients. This suggested that solute diffusion in wastes requires further study.

  19. Testing of a benchscale Reverse Osmosis/Coupled Transport system for treating contaminated groundwater

    International Nuclear Information System (INIS)

    Hodgson, K.M.; Lunsford, T.R.; Panjabi, G.

    1994-01-01

    The Reverse Osmosis/Coupled Transport process is a innovative means of removing radionuclides from contaminated groundwater at the Hanford Site. Specifically, groundwater in the 200 West Area of the Hanford Site has been contaminated with uranium, technetium, and nitrate. Investigations are proceeding to determine the most cost effective method to remove these contaminants. The process described in this paper combines three different membrane technologies (reverse osmosis, coupled transport, and nanofiltration to purify the groundwater while extracting and concentrating uranium, technetium, and nitrate into separate solutions. This separation allows for the future use of the radionuclides, if needed, and reduces the amount of waste that will need to be disposed of. This process has the potential to concentrate the contaminants into solutions with volumes in a ratio of 1/10,000 of the feed volume. This compares to traditional volume reductions of 10 to 100 for ion exchange and stand-alone reverse osmosis. The successful demonstration of this technology could result in significant savings in the overall cost of decontaminating the groundwater

  20. Contaminant transport modeling studies of Russian sites

    International Nuclear Information System (INIS)

    Tsang, Chin-Fu

    1993-01-01

    Lawrence Berkeley Laboratory (LBL) established mechanisms that promoted cooperation between U.S. and Russian scientists in scientific research as well as environmental technology transfer. Using Russian experience and U.S technology, LBL developed approaches for field investigations, site evaluation, waste disposal, and remediation at Russian contaminated sites. LBL assessed a comprehensive database as well as an actual, large-scale contaminated site to evaluate existing knowledge of and test mathematical models used for the assessment of U.S. contaminated sites

  1. Decrease DNA contamination in the laboratories

    DEFF Research Database (Denmark)

    Kampmann, Marie-Louise; Børsting, Claus; Morling, Niels

    2017-01-01

    In this study, we tested various approaches to remove DNA from hard laboratory surfaces. We contaminated clean surfaces with four different concentrations of massively parallel sequencing libraries. The DNA was dried and left for 45 min and for 24 h, respectively, before any treatment. The surfaces.......9–1.8% hypochlorite in order to eliminate laboratory contamination and simultaneously minimise any poisonous gases....

  2. Corrective Action Plan for Corrective Action Unit 143: Area 25 Contaminated Waste Dumps, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    Gustafason, D.L.

    2001-01-01

    This Corrective Action Plan (CAP) has been prepared for Corrective Action Unit (CAU) 143: Area 25 Contaminated Waste Dumps, Nevada Test Site, Nevada, in accordance with the Federal Facility Agreement and Consent Order of 1996. This CAP provides the methodology for implementing the approved corrective action alternative as listed in the Corrective Action Decision Document (U.S. Department of Energy, Nevada Operations Office, 2000). The CAU includes two Corrective Action Sites (CASs): 25-23-09, Contaminated Waste Dump Number 1; and 25-23-03, Contaminated Waste Dump Number 2. Investigation of CAU 143 was conducted in 1999. Analytes detected during the corrective action investigation were evaluated against preliminary action levels to determine constituents of concern for CAU 143. Radionuclide concentrations in disposal pit soil samples associated with the Reactor Maintenance, Assembly, and Disassembly Facility West Trenches, the Reactor Maintenance, Assembly, and Disassembly Facility East Trestle Pit, and the Engine Maintenance, Assembly, and Disassembly Facility Trench are greater than normal background concentrations. These constituents are identified as constituents of concern for their respective CASs. Closure-in-place with administrative controls involves use restrictions to minimize access and prevent unauthorized intrusive activities, earthwork to fill depressions to original grade, placing additional clean cover material over the previously filled portion of some of the trenches, and placing secondary or diversion berm around pertinent areas to divert storm water run-on potential

  3. Forensic Luminol Blood Test for Preventing Cross-contamination in Dentistry: An Evaluation of a Dental School Clinic

    OpenAIRE

    Marcelo Carlos Bortoluzzi; Peterson Cadore; Andrea Gallon; Soraia Almeida Watanabe Imanishi

    2014-01-01

    Background: More than 200 different diseases may be transmitted from exposure to blood in the dental setting. The aim of this study is to identify possible faults in the cross-contamination chain control in a dental school clinic searching for traces of blood in the clinical contact surfaces (CCS) through forensic luminol blood test. Methods: Traces of invisible blood where randomly searched in CCS of one dental school clinic. Results: Forty eight surfaces areas in the CCS were tes...

  4. Effect of crude oil contamination on the engineering behavior of clay soils

    International Nuclear Information System (INIS)

    Rehman, H.; Abdoljaowad, S.N.

    2005-01-01

    Humans are, unintentionally or intentionally contaminating soil from different sources. The contaminated soil are not only a challenge for the environmentalists but also for geotechnical engineers. When contaminated by crude oil, the soil is subjected to a change in its engineering properties. The soil, which is mostly affected by its environment, is clay, being active electro-chemically. So, a comprehensive laboratory-testing program was performed to compare the engineering properties of an uncontaminated and a contaminated clay. Laboratory tests included all basic and advanced geotechnical tests along with Scanning Electron Microscope (SEM). Crude oil was chosen as the contaminant. The clay was taken from the Al-Qatif area of the Eastern province of Saudi Arabia. The selected soil is considered to be highly expansive in nature. The comparison between uncontaminated and crude oil contaminated clay showed that there would be a significant change in the engineering behavior of the clay if it were contaminated by crude oil. The contaminated clay behaves more like sand, owing to the formation of agglomerates. The coarse-grained soil-like behavior was observed in the strength of the oil-contaminated clay. The contamination has affected the plasticity and the cation exchange capacity of the investigated clay. The swelling pressure of the contaminated clay is 1/3 of that of the uncontaminated clay while the swelling is almost the same. (author)

  5. Thermal remediation of tar-contaminated soil and oil-contaminated gravel

    International Nuclear Information System (INIS)

    Anthony, E.J.; Wang, J.

    2005-01-01

    High temperature treatments are commonly considered for the decontamination of soil as they have the advantages of reliability, high capacity, and effective destruction of hazardous materials with reduced long-term liability. This paper examined the remediation of soil contaminated by coal tar as well as gravel contaminated by oil. Pilot plant studies were conducted using 2 representative incineration technologies: rotary kiln and fluidized bed. The coal tar contaminated soil had accumulated over a few decades at a calcination plant in western Canada. The soil was sticky and could not be handled by conventional feeding and combustion systems. Crushed lignite was mixed with the soil as an auxiliary fuel and to reduce stickiness. A pilot plant furnace was used to evaluate the potential of decontamination in a rotary calciner. An analysis of both a modelling study and the test results showed that complete decontamination could be achieved in the targeted calciner. The results suggested that energy recovery was also possible, which could in turn make the remediation process more cost-effective. Decontamination of oil-contaminated gravel was conducted with a pilot plant fluidized bed combustor to study the feasibility of using incineration technology in the remediation of gravel and debris contaminated by oil spills. Results indicated that the gravel was decontaminated with acceptable emission performance. It was concluded that the study will be valuable to the application of commercial incineration processes for the remediation of polluted soils. It was observed that the weathering of the oiled gravel lowered the rate of decontamination. A small amount of salt water resulted in lowered decontamination rates, which may be an important factor for situations involving the remediation of shoreline gravel contaminated by oil. 24 refs., 6 tabs., 7 figs

  6. Air separation of heavy metal contaminants from soil

    International Nuclear Information System (INIS)

    Nelson, M.E.; Harper, M.J.; Buckon, A.D.

    1995-01-01

    Several heavy metal separation techniques are currently being developed for soil remediation at various Department of Defense and Department of Energy (DOE) Facilities. The majority of these techniques involve a wet process using water, pH modifiers or other compounds. The US Naval Academy (USNA) has developed a dry process for heavy metal separation. The process uses air classification technology to concentrate the metal contaminant into a fraction of the soil. The advantages of this dry process are that it creates no contaminated byproduct and uses commercially available technology. The USNA process is based on using a Gayco-Reliance air classifier. Tests have been conducted with the system at the Naval Academy and the University of Nevada-Reno (UNR). The USNA tests used soil from the Nevada Test Site mixed with bismuth at a concentration of 500--1,000 ppm. The UNR tests used soil from four DOE sites mixed with uranium oxides and plutonium at an activity level of 100--700 pCi per gram. Concentration of activities and volume reduction percentages are presented for the various soils and contaminants tested

  7. Standard Test Method for Sizing and Counting Particulate Contaminant In and On Clean Room Garments

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers the determination of detachable particulate contaminant 5 m or larger, in and on the fabric of clean room garments. 1.2 This test method does not apply to nonporous fabrics such as Tyvek or Gortex. It only applies to fabrics that are porous such as cotton or polyester. 1.3 The values stated in SI units are to be regarded as the standard. The inch-pound values given in parentheses are for information only. 1.4 This test method provides not only the traditional optical microscopic analysis but also a size distribution and surface obscuration analysis for particles on a fine-textured membrane filter or in a tape lift sample. It utilizes transmitted illumination to render all particles darker than the background for gray level detection. Particles collected on opaque plates must be transferred to a suitable membrane filter. This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associat...

  8. Assessment of the consequences of the radioactive contamination of aquatic media and biota for the Chernobyl NPP cooling pond: model testing using Chernobyl data

    International Nuclear Information System (INIS)

    Kryshev, I.I.; Sazykina, T.G.; Hoffman, F.O.; Thiessen, K.M.; Blaylock, B.G.; Feng, Y.; Galeriu, D.; Heling, R.; Kryshev, A.I.; Kononovich, A.L.; Watkins, B.

    1998-01-01

    The 'Cooling Pond' scenario was designed to test models for radioactive contamination of aquatic ecosystems, based on data from the Chernobyl Nuclear Power Plant cooling pond, which was heavily contaminated in 1986 as a result of the reactor accident. The calculation tasks include (a) reconstruction of the dynamics of radionuclide transfer and bioaccumulation in aquatic media and biota following the accident; (b) assessment of doses to aquatic biota; and (c) assessment of potential doses and radiation risks to humans from consumption of contaminated fish. Calculations for the Scenario were performed by 19 participants using 6 different models: LAKECO-B (Netherlands); LAKEPOND (Romania); POSOD (USA); WATER, GIDRO and ECOMOD-W (Russia). For all endpoints, model predictions were compared with the test data, which were derived from the results of direct measurements and independent dose estimates based on measurements. Most of the models gave satisfactory agreement for some portions of the test data, although very few participants obtained good agreement with all criteria for model testing. The greatest level of difficulty was with the prediction of non-equilibrium radioecological processes in the first year after the accident (1986). The calculations 5 for this scenario gave modellers a unique opportunity to test their models using an independent data base and to analyse the advantages and weaknesses of different model approaches. The use of post-Chernobyl data in such a scenario is also recommended for use in training students in the field of radioecology and environmental protection. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  9. Radioactive Contamination Tenacity on Building Substrate – 17417

    Energy Technology Data Exchange (ETDEWEB)

    Demmer, Rick; Boxall, Colin

    2017-01-01

    Radiological decontamination is an essential enterprise that has become more important over the last four decades due to unfortunate accidents and the threat of terrorist actions. Decontamination can be an effective, beneficial alternative for the cleanup of radiological contamination events; however, the costs and benefits need to be balanced against those for complete removal and demolition of contaminated areas or facilities. Demolition and removal are often the first options considered in such circumstances as decontamination may be thought of as slow and costly. Decontamination has advantages, including significant waste reduction over demolition. In areas with buildings of cultural or societal importance, demolition may not be an option. Three decontamination evaluation test series are the focus of this article: SIMCON 1 and 2 (i.e., simulated contamination), and Urban RDD (radiological dispersal device, i.e., a dirty bomb detonation). These test series revealed that different contaminants respond differently during decontamination. This was found to be true with both SIMCON and Urban RDD simulant tests. SIMCON 2 especially demonstrated that chemically different contaminants respond differently to different decontamination methods: cesium appears to be less tenacious (more easily removed) than zirconium using chemical methods. These differences were underscored by the Urban RDD tests where americium and cobalt tended to precipitate on high pH surfaces (such as concrete), making them easier to remove, while cesium and strontium were essentially unaffected by surface pH and were imbibed more strongly into the substrate pore structure. While authorities argue over the contributions of contaminant chemistry and substrate morphology, the clear answer is that each has a contribution to the tenacity of a contaminant. Knowing how these characteristics interact will make us better at decontamination in the field. This knowledge refutes the efforts of perhaps well

  10. Level of Campylobacter jejuni from naturally contaminated chicken liver and chicken legs in various task: a cross contamination study

    Directory of Open Access Journals (Sweden)

    New, C.Y.

    2017-03-01

    Full Text Available Cross contamination is one of the most important contributing factors in foodborne illness originating in household environments. The objective of this research was to determine the transfer between naturally contaminated chicken liver and leg to cutting board, hand glove, knife and cucumber, during slicing. The microorganism tested was Campylobacter jejuni and the results showed that the pathogen transferred to all utensils, at different transfer rate, despite the low level of the naturally contaminating pathogen. With unknown concentration bacteria in the naturally contaminated samples, a proportion of the utensils were still contaminated with C. jejuni and not surprisingly, when the sample were contaminated with higher concentrations of the pathogen, a higher proportion of the utensils had detectable C. jejuni cells present, though in many cases cross contamination seems to be a random event. Transfer of the naturally contaminating C. jejuni from the chicken liver and leg to the utensils were <3.0 to 9.2 MPN/g and <3.0 to 3.0 MPN/g, respectively. The results of this study highlighted the potential for cross contamination of food borne pathogens in the kitchen environment.

  11. Cleaning, disinfection and sterilization of surface prion contamination.

    Science.gov (United States)

    McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E

    2013-12-01

    Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  12. Microbial Contamination of Pastry Cream: Evidence from Iran

    Directory of Open Access Journals (Sweden)

    Mohamadreza Pajohi-alamoti

    2016-07-01

    Full Text Available Background & Aims of the Study: Given the importance of microbial contamination in creating food-borne diseases, this study was conducted to assess level of microbial contamination of pastry creams in Hamedan, Iran. Materials and Methods: Totally, 80 samples were randomly collected from the confectioneries and analyzed for microbial contamination according to Iranian national standard microbial tests. Results: Data indicated that 49 (61.2% samples were contaminated, mostly comprised of Coliforms (92.5%. Moreover, the infection was seen to be higher in jelly roll compared to puff pastry. Yeast contamination was about 82.5 percent, which could accelerate the decay of such products. However, yeast contamination of puff pastries was higher than jelly roll. The microbial contamination with Staphylococcus aureus, total viable count and molds were 57.5%, 35% and 37.5%; respectively. Conclusion: Nevertheless, Salmonella, Escherichia coli and Listeria monocytogenes were not found in any of the samples. Abundance of microbial contamination in the puff pastry samples might put consumer’s health at risk.

  13. Environmental analysis of contaminated sites

    National Research Council Canada - National Science Library

    Sunahara, G.I; Renoux, A; Thellen, C; Gaudet, C.L; Pilon, A

    2002-01-01

    .... Topics addressed include: the integration of terrestrial ecotoxicity testing with respect to a chemical's behaviour in soil, developments in contaminated soil risk assessment, and the use of advanced scientific data...

  14. A new improved protocol for in vitro intratubular dentinal bacterial contamination for antimicrobial endodontic tests: standardization and validation by confocal laser scanning microscopy

    Directory of Open Access Journals (Sweden)

    Flaviana Bombarda de ANDRADE

    2015-01-01

    Full Text Available Objectives To compare three methods of intratubular contamination that simulate endodontic infections using confocal laser scanning microscopy (CLSM. Material and Methods Two pre-existing models of dentinal contamination were used to induce intratubular infection (groups A and B. These methods were modified in an attempt to improve the model (group C. Among the modifications it may be included: specimen contamination for five days, ultrasonic bath with BHI broth after specimen sterilization, use of E. faecalis during the exponential growth phase, greater concentration of inoculum, and two cycles of centrifugation on alternate days with changes of culture media. All specimens were longitudinally sectioned and stained with of LIVE/DEAD® for 20 min. Specimens were assessed using CLSM, which provided images of the depth of viable bacterial proliferation inside the dentinal tubules. Additionally, three examiners used scores to classify the CLSM images according to the following parameters: homogeneity, density, and depth of the bacterial contamination inside the dentinal tubules. Kruskal-Wallis and Dunn’s tests were used to evaluate the live and dead cells rates, and the scores obtained. Results The contamination scores revealed higher contamination levels in group C when compared with groups A and B (p0.05. The volume of live cells in group C was higher than in groups A and B (p<0.05. Conclusion The new protocol for intratubular infection resulted in high and uniform patterns of bacterial contamination and higher cell viability in all specimens when compared with the current methods.

  15. Bioremediation of soil contaminated crude oil by Agaricomycetes.

    Science.gov (United States)

    Mohammadi-Sichani, M Maryam; Assadi, M Mazaheri; Farazmand, A; Kianirad, M; Ahadi, A M; Ghahderijani, H Hadian

    2017-01-01

    One of the most important environmental problems is the decontamination of petroleum hydrocarbons polluted soil, particularly in the oil-rich country. Bioremediation is the most effective way to remove these pollutants in the soil. Spent mushroom compost has great ability to decompose lignin-like pollution. The purpose of this study was the bioremediation of soil contaminated with crude oil by an Agaricomycetes . Soil sample amended with spent mushroom compost into 3%, 5% and 10% (w/w) with or without fertilizer. Ecotoxicity germination test was conducted with Lipidium sativa . The amplified fragment (18 s rDNA) sequence of this mushroom confirmed that the strain belonged to Pleurotus ostreatus species with complete homology (100% identity). All tests experiment sets were effective at supporting the degradation of petroleum hydrocarbons contaminated soil after three months. Petroleum contaminated soil amended with Spent mushroom compost 10% and fertilizer removed 64.7% of total petroleum hydrocarbons compared control. The germination index (%) in ecotoxicity tests ranged from 60.4 to 93.8%. This showed that the petroleum hydrocarbons contaminated soil amended with 10% Spent mushroom compost had higher bioremediation ability and reduced soil toxicity in less than three months.

  16. Immobilization of Lead from Pb-Contaminated Soil Amended with Peat Moss

    Directory of Open Access Journals (Sweden)

    Seul-Ji Lee

    2013-01-01

    Full Text Available Immobilization of lead (Pb using soil amendments can reduce Pb toxicity and bioavailability in soil. This study evaluated Pb immobilization in a Pb-contaminated soil by using peat moss through various tests. The Pb-contaminated soil (2000 mg Pb·kg−1 was amended with 1%, 5%, and 10% of peat moss to immobilize Pb in the soil. The immobilization properties of Pb in the contaminated soil were evaluated by a column leaching experiment, a microcosm test, and a batch incubation test. Peat moss significantly reduced the Pb leaching in all of the experiments and more effectively reduced mobility and toxicity of Pb in the column leaching and microcosm tests than bioavailability in the batch incubation test. The immobilized lead from the soils amended with 1%, 5%, and 10% of peat moss was 37.9%, 87.1%, and 95.4% from the column leaching test, 18.5%, 90.9%, and 96.4% from the microcosm test, and 2.0%, 36.9%, and 57.9% from the NH4NO3 extraction method, respectively, indicating that peat moss can be effectively used for the remediation of Pb-contaminated soil.

  17. Prohibited Contaminants in Dietary Supplements.

    Science.gov (United States)

    Mathews, Neilson M

    With the increasing use of unregulated dietary supplements, athletes are at continued risk from adverse medical events and inadvertent doping. A review of Clinical Key, MEDLINE, and PubMed databases from 2012 to 2017 was performed using search terms, including dietary supplement, contamination, doping in athletes, inadvertent doping, and prohibited substances. The references of pertinent articles were reviewed for other relevant sources. Clinical review. Level 3. Poor manufacturing processes and intentional contamination with many banned substances continue to occur in dietary supplements sold in the United States. Certain sectors, such as weight loss and muscle-building supplements, pose a greater threat because they are more likely to be contaminated. Athletes will continue to be at risk for adverse events and failed doping tests due to contaminated dietary supplements until legislation changes how they are regulated. In the interim, there are several steps that can be taken to mitigate this risk, including improved education of medical staff and athletes and use of third party-certified products.

  18. 100-D Area In Situ Redox Treatability Test for Chromate-Contaminated Groundwater

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Mark D.; Vermeul, Vincent R.; Szecsody, James E.; Fruchter, Jonathan S.

    2000-10-12

    A treatability test was conducted for the In Situ Redox Manipulation (ISRM) technology at the 100 D Area of the U. S. Department of Energy's Hanford Site. The target contaminant was dissolved chromate in groundwater. The ISRM technology creates a permeable subsurface treatment zone to reduce mobile chromate in groundwater to an insoluble form. The ISRM permeable treatment zone is created by reducing ferric iron to ferrous iron within the aquifer sediments, which is accomplished by injecting aqueous sodium dithionite into the aquifer and then withdrawing the reaction products. The goal of the treatability test was to create a linear ISRM barrier by injecting sodium dithionite into five wells. Well installation and site characterization activities began in spring 1997; the first dithionite injection took place in September 1997. The results of this first injection were monitored through the spring of 1998. The remaining four dithionite injections were carried out in May through July of 1998.These five injections created a reduced zone in the Hanford unconfined aquifer approximately 150 feet in length (perpendicular to groundwater flow) and 50 feet wide. The reduced zone extended over the thickness of the unconfined zone. Analysis of post-emplacement groundwater samples showed concentrations of chromate, in the reduced zone decreased from approximately 1.0 mg/L before the tests to below analytical detection limits (<0.007 mg/L). Chromate concentrations also declined in downgradient monitoring wells to as low as 0.020 mg/L. These data, in addition to results from pre-test reducible iron characterization, indicate the barrier should be effective for 20 to 25 years. The 100-D Area ISRM barrier is being expanded to a length of up to 2,300 ft to capture a larger portion of the chromate plume.

  19. Best Practices for Fuel System Contamination Detection and Remediation

    Science.gov (United States)

    2016-01-15

    The University of Dayton Research Institute Best Practices for Fuel System Contamination Detection and Remediation Final Report Marlin D... Remediation Executive Summary: Fuel contamination is a broad term commonly applied to anything that causes a fuel test to fail quality assurance...Statement A: Approved for public release: distribution unlimited. 1 Best Practices for Fuel System Contamination Detection and Remediation Contents

  20. Soil contamination studies

    International Nuclear Information System (INIS)

    1997-06-01

    The objective of this project was to develop a quick screening method that accurately identifies and quantifies the amount of alpha-emitting radionuclides in infinitely-thick soil samples using a Frisch grid ionization chamber. An additional objective of the work was to provide the US Department of Energy, Nevada Operations Office and its contractors with information on the theoretical and actual measured results of atmospheric testing contamination of soil and water at the Nevada Test Site through a comprehensive search of existing literature

  1. Contamination by Helicobacter pylori measured by the 13C-Urea-Breath-Test and nutritional status of children with chronic diarrhoea syndrome in Havana City

    International Nuclear Information System (INIS)

    Hernandez-Triana, M.H.; Cabrera, A.; Sanchez, M. A.; Herrera, X.; Pawong, M.; Moreno, R.; Reyes, D.; Serrano, G.; Diaz, M.E.

    2002-01-01

    Diarrhoea morbidity shows a slow increasing tendency during the last 10 years in Cuba. In young children the compromise of the gastric acid barrier after a chronic infection with Helicobacter pylori (Hp) is discussed in pathogenic relation to gastritis, duodenal ulcer, chronic diarrhoea, short stature, malabsorption of the B-complex vitamins and malnutrition. The Hp contamination level of the population of the developing world is estimated to be considerably high. Endoscopic studies carried out in Cuban subjects with upper gastrointestinal symptoms show contamination values of 60 to 100%. The current treatment of chronic diarrhoea does not include the elimination of Hp. Cuban children with upper gastrointestinal symptoms show contamination values of more than 60%. There are not available data on the contamination level in apparently healthy Cuban children or those with chronic diarrhoea. In March-April 2000 the prevalence of Hp infection measured in serum by chromatographic immunoassay for detection of Hp IgG antibodies was found to be 94 % in 20 infants and young children with persistent chronic diarrhoea and 100% in 11 apparently healthy children in Havana City. Children with diarrhoea showed a more evident affection of their nutritional status and a higher percentage of positive personal or familiar history of parasitism, giardiasis, gastritis, ulcer, stomatitis and glositis. The validity of the immunological tests in infants is discussed from the point of view of the antibody transference with breast milk. In a sample of 16 different children studied by the 13C-Urea-Breath-Test the contamination level was 50% of the children not affected by diarrhoea and only one of the 6 children with diarrhoea showed positive values

  2. Evaluation through column leaching tests of metal release from contaminated estuarine sediment subject to CO2 leakages from Carbon Capture and Storage sites

    International Nuclear Information System (INIS)

    Payán, M. Cruz; Galan, Berta; Coz, Alberto; Vandecasteele, Carlo; Viguri, Javier R.

    2012-01-01

    The pH change and the release of organic matter and metals from sediment, due to the potential CO 2 acidified seawater leakages from a CCS (Carbon Capture and Storage) site are presented. Column leaching test is used to simulate a scenario where a flow of acidified seawater is in contact with recent contaminated sediment. The behavior of pH, dissolved organic carbon (DOC) and metals As, Cd, Cr, Cu, Ni, Pb, Zn, with liquid to solid (L/S) ratio and pH is analyzed. A stepwise strategy using empirical expressions and a geochemical model was conducted to fit experimental release concentrations. Despite the neutralization capacity of the seawater-carbonate rich sediment system, important acidification and releases are expected at local scale at lower pH. The obtained results would be relevant as a line of evidence input of CCS risk assessment, in an International context where strategies to mitigate the climate change would be applied. - Highlights: ► Tier structured approach for assessment of the release of metals from sediment. ► Standard column leaching test to simulate CO 2 acidified seawater CCS leakages. ► Metal and DOC release from marine sediment in contact to CO 2 acidified seawater. ► From empirical to geochemical modeling approaches of DOC and metals release in column tests. ► Contamination line of evidence input of CCS risk assessment. - Column metal release from CO 2 acidified seawater leakages in contact with estuarine contaminated sediment in CCS sites

  3. Directional phytoscreening: contaminant gradients in trees for plume delineation.

    Science.gov (United States)

    Limmer, Matt A; Shetty, Mikhil K; Markus, Samantha; Kroeker, Ryan; Parker, Beth L; Martinez, Camilo; Burken, Joel G

    2013-08-20

    Tree sampling methods have been used in phytoscreening applications to delineate contaminated soil and groundwater, augmenting traditional investigative methods that are time-consuming, resource-intensive, invasive, and costly. In the past decade, contaminant concentrations in tree tissues have been shown to reflect the extent and intensity of subsurface contamination. This paper investigates a new phytoscreening tool: directional tree coring, a concept originating from field data that indicated azimuthal concentrations in tree trunks reflected the concentration gradients in the groundwater around the tree. To experimentally test this hypothesis, large diameter trees were subjected to subsurface contaminant concentration gradients in a greenhouse study. These trees were then analyzed for azimuthal concentration gradients in aboveground tree tissues, revealing contaminant centroids located on the side of the tree nearest the most contaminated groundwater. Tree coring at three field sites revealed sufficiently steep contaminant gradients in trees reflected nearby groundwater contaminant gradients. In practice, trees possessing steep contaminant gradients are indicators of steep subsurface contaminant gradients, providing compass-like information about the contaminant gradient, pointing investigators toward higher concentration regions of the plume.

  4. Electrical Tracking Formation on Silane Epoxy Resin under Various Contaminants

    Directory of Open Access Journals (Sweden)

    NFN Rochmadi

    2013-03-01

    Full Text Available Contamination at the surface of the insulator becomes a serious problem in power system operation, especially for the tropical area. Humidity and rainfall play an important role in wetness by the water at the surface of the insulator, which result in the presence of contaminant and leakage current flowing at the surface of the insulator. This leakage current will generate heat which occurs at the surface of an insulator, so that dry band area will be formed. This ultimately leads to flashover. This paper presents the influence of contaminants to leakage current and formation of electrical tracking at the surface of epoxy resin compound wit silicon rubber. The test was based on Inclined-Planed Tracking method with NH4Cl as contaminants. The industrial and coastal contaminants are used to explain the effect of contaminant at surface tracking process. The flow rate of contaminant was 0.3 ml/min. The 3.5 kV AC high voltage 50 Hz was applied to the top electrodes. It is found that industrial contamination resulting in the smallest surface leakage current is 327.6 mA. Also it is found that coastal contaminant (1420 mS/cm showed the severest damage at surface of test sample. Therefore, special treatment of the sample are needed under these conditions so that the material performance can be improved, especially against the electrical tracking.

  5. Disinfection of contaminated water by using solar irradiation.

    Science.gov (United States)

    Caslake, Laurie F; Connolly, Daniel J; Menon, Vilas; Duncanson, Catriona M; Rojas, Ricardo; Tavakoli, Javad

    2004-02-01

    Contaminated water causes an estimated 6 to 60 billion cases of gastrointestinal illness annually. The majority of these cases occur in rural areas of developing nations where the water supply remains polluted and adequate sanitation is unavailable. A portable, low-cost, and low-maintenance solar unit to disinfect unpotable water has been designed and tested. The solar disinfection unit was tested with both river water and partially processed water from two wastewater treatment plants. In less than 30 min in midday sunlight, the unit eradicated more than 4 log10 U (99.99%) of bacteria contained in highly contaminated water samples. The solar disinfection unit has been field tested by Centro Panamericano de Ingenieria Sanitaria y Ciencias del Ambiente in Lima, Peru. At moderate light intensity, the solar disinfection unit was capable of reducing the bacterial load in a controlled contaminated water sample by 4 log10 U and disinfected approximately 1 liter of water in 30 min.

  6. Groundwater arsenic contamination throughout China.

    Science.gov (United States)

    Rodríguez-Lado, Luis; Sun, Guifan; Berg, Michael; Zhang, Qiang; Xue, Hanbin; Zheng, Quanmei; Johnson, C Annette

    2013-08-23

    Arsenic-contaminated groundwater used for drinking in China is a health threat that was first recognized in the 1960s. However, because of the sheer size of the country, millions of groundwater wells remain to be tested in order to determine the magnitude of the problem. We developed a statistical risk model that classifies safe and unsafe areas with respect to geogenic arsenic contamination in China, using the threshold of 10 micrograms per liter, the World Health Organization guideline and current Chinese standard for drinking water. We estimate that 19.6 million people are at risk of being affected by the consumption of arsenic-contaminated groundwater. Although the results must be confirmed with additional field measurements, our risk model identifies numerous arsenic-affected areas and highlights the potential magnitude of this health threat in China.

  7. Atmospheric contamination

    International Nuclear Information System (INIS)

    Gruetter, Juerg

    1997-01-01

    It is about the levels of contamination in center America, the population's perception on the problem, effects of the atmospheric contamination, effects in the environment, causes of the atmospheric contamination, possibilities to reduce the atmospheric contamination and list of Roeco Swisscontac in atmospheric contamination

  8. Survey of radioactive contamination for foodstuffs

    International Nuclear Information System (INIS)

    Lee, Wan No; Lee, Chang Wu; Choi, Geun Sik; Cho, Yeong Hyeon; Kang, Mun Ja; Cheong, Geun Ho; Kim, Hui Ryeong; Park, Du Won; Park, Hyo Guk; Kwak, Ji Yeon

    2006-11-01

    After the Chernobyl nuclear accident in 1986, a lot of countries including EU, Japan, USA are to strengthen survey of radioactive contamination for foodstuffs. Our country has also surveyed radioactive contamination of the imported foodstuffs and started to check continuously the radioactivity contamination of the open market foodstuffs since 2003. In this year, imported foodstuffs(130 samples) and domestic foodstuffs(10 samples) are analyzed to investigate the radioactive contamination. Sampled foodstuffs items are collected from the open markets; one group is the imported foodstuffs and the other group is the domestic foodstuffs producted around nuclear facilities and northeast of Sokcho city concerning recent situations. Samples are usually bought from traditional markets, mart, department store or the Internet. After pretreatments such as drying, ashing, and homogenization, all samples were analyzed by gamma spectrometer system for survey and assessment of radioactive contamination. The 131 I radionuclide isn't detected among all foodstuffs(imported and domestic). The 137 Cs radionuclide among the regulation radionuclides( 137 Cs, 13 4 C s, 131 I) of food code is only detected at the imported foodstuffs but its level is far below the maximum permitted level. For the improvement of measurement confidence, the developed analysis method is tested by the participation of the national and international intercomparison. The developed method based on test results and international standard would be used at radioactive analysis as well as an education of relative workers. It could be applied as the basis data for amending the analysis method of food code. It is technically supported for radioactive analysis of commercial company and the government including KFDA. Finally these results would be used to solve an ambiguous anxiety of a people for radiation exposure by foodstuffs intake and help the KFDA to manage systematically the radioactive contamination and to give

  9. UNDERWATER COATINGS FOR CONTAMINATION CONTROL

    International Nuclear Information System (INIS)

    Julia L. Tripp; Kip Archibald; Ann Marie Phillips; Joseph Campbell

    2004-01-01

    The Idaho National Laboratory (INL) deactivated several aging nuclear fuel storage basins. Planners for this effort were greatly concerned that radioactive contamination present on the basin walls could become airborne as the sides of the basins became exposed during deactivation and allowed to dry after water removal. One way to control this airborne contamination was to fix the contamination in place while the pool walls were still submerged. There are many underwater coatings available on the market for marine, naval and other applications. A series of tests were run to determine whether the candidate underwater fixatives were easily applied and adhered well to the substrates (pool wall materials) found in INL fuel pools. Lab-scale experiments were conducted by applying fourteen different commercial underwater coatings to four substrate materials representative of the storage basin construction materials, and evaluating their performance. The coupons included bare concrete, epoxy painted concrete, epoxy painted carbon steel, and stainless steel. The evaluation criteria included ease of application, adherence to the four surfaces of interest, no change on water clarity or chemistry, non-hazardous in final applied form and be proven in underwater applications. A proprietary two-part, underwater epoxy owned by S. G. Pinney and Associates was selected from the underwater coatings tested for application to all four pools. Divers scrubbed loose contamination off the basin walls and floors using a ship hull scrubber and vacuumed up the sludge. The divers then applied the coating using a special powered roller with two separate heated hoses that allowed the epoxy to mix at the roller surface was used to eliminate pot time concerns. The walls were successfully coated and water was removed from the pools with no detectable airborne contamination releases

  10. Toxic element contamination of natural health products and pharmaceutical preparations.

    Directory of Open Access Journals (Sweden)

    Stephen J Genuis

    Full Text Available BACKGROUND: Concern has recently emerged regarding the safety of natural health products (NHPs-therapies that are increasingly recommended by various health providers, including conventional physicians. Recognizing that most individuals in the Western world now consume vitamins and many take herbal agents, this study endeavored to determine levels of toxic element contamination within a range of NHPs. METHODS: Toxic element testing was performed on 121 NHPs (including Ayurvedic, traditional Chinese, and various marine-source products as well as 49 routinely prescribed pharmaceutical preparations. Testing was also performed on several batches of one prenatal supplement, with multiple samples tested within each batch. Results were compared to existing toxicant regulatory limits. RESULTS: Toxic element contamination was found in many supplements and pharmaceuticals; levels exceeding established limits were only found in a small percentage of the NHPs tested and none of the drugs tested. Some NHPs demonstrated contamination levels above preferred daily endpoints for mercury, cadmium, lead, arsenic or aluminum. NHPs manufactured in China generally had higher levels of mercury and aluminum. CONCLUSIONS: Exposure to toxic elements is occurring regularly as a result of some contaminated NHPs. Best practices for quality control-developed and implemented by the NHP industry with government oversight-is recommended to guard the safety of unsuspecting consumers.

  11. Analysis of Salmonella sp bacterial contamination on Vannamei Shrimp using binary logit model approach

    Science.gov (United States)

    Oktaviana, P. P.; Fithriasari, K.

    2018-04-01

    Mostly Indonesian citizen consume vannamei shrimp as their food. Vannamei shrimp also is one of Indonesian exports comodities mainstay. Vannamei shrimp in the ponds and markets could be contaminated by Salmonella sp bacteria. This bacteria will endanger human health. Salmonella sp bacterial contamination on vannamei shrimp could be affected by many factors. This study is intended to identify what factors that supposedly influence the Salmonella sp bacterial contamination on vannamei shrimp. The researchers used the testing result of Salmonella sp bacterial contamination on vannamei shrimp as response variable. This response variable has two categories: 0 = if testing result indicate that there is no Salmonella sp on vannamei shrimp; 1 = if testing result indicate that there is Salmonella sp on vannamei shrimp. There are four factors that supposedly influence the Salmonella sp bacterial contamination on vannamei shrimp, which are the testing result of Salmonella sp bacterial contamination on farmer hand swab; the subdistrict of vannamei shrimp ponds; the fish processing unit supplied by; and the pond are in hectare. This four factors used as predictor variables. The analysis used is Binary Logit Model Approach according to the response variable that has two categories. The analysis result indicates that the factors or predictor variables which is significantly affect the Salmonella sp bacterial contamination on vannamei shrimp are the testing result of Salmonella sp bacterial contamination on farmer hand swab and the subdistrict of vannamei shrimp ponds.

  12. Record of Technical Change No.2 for ''Corrective Action Investigation Plan for Corrective Action Unit 143: Area 25 Contaminated Waste Dumps, Nevada Test Site, Nevada''

    International Nuclear Information System (INIS)

    1999-01-01

    This Record of Technical Change provides updates to the technical information included in ''Corrective Action Investigation Plan for Corrective Action Unit 143: Area 25 Contaminated Waste Dumps, Nevada Test Site, Nevada.''

  13. Results of a cleanup and treatment test at the Nevada test site: Evaluation of vacuum removal of Pu-contaminated soil

    International Nuclear Information System (INIS)

    Shinn, J.H.; Essington, E.H.; Miller, F.L. Jr.; O'Farrell, T.P.; Orcutt, J.A.; Romney, E.M.; Shugart, J.W.; Sorom, E.R.

    1989-01-01

    We have conducted experiments to evaluate the effectiveness of removing contaminated soils from the Nevada Test Site with a large truck-mounted vacuum cleaner. Our results show that this method is effective, relatively easy, and safe for equipment operators. With four passes of the truck-mounted vacuum, 92% of the 241Am (and the accompanying 239 + 240Pu) was removed and resuspension rates were reduced by more than 99%. The ecological impact was, however, serious in terms of soil erosion and destruction of small animal habitats. Compared to standard earth-moving techniques, vacuuming permits a significant reduction in the volume of soil collected to achieve the desired level of decontamination, and the volume reduction could result in cost savings for packaging, shipment, and burial. This cost savings would only be realized for projects involving decontamination of the top 5 cm of soil

  14. ONSITE ENGINEERING REPORT FOR SOLIDIFICATION/ STABILIZATION TREATMENT TESTING OF CONTAMINATED SOILS

    Science.gov (United States)

    The EPA's Office of Solid Waste and Emergency Response (OSWER) is currently developing land disposal restrictions (LDRs) for contaminated soil and debris (CS&D). The Office of Research and Development, through its Risk Reduction Engineering Laboratory (RREL), is providing support...

  15. Aging effects on oil-contaminated Kuwaiti sand

    International Nuclear Information System (INIS)

    Al-Sanad, H.A.; Ismael, N.F.

    1997-01-01

    Large quantities of oil-contaminated sands resulted from the destruction of oil wells and the formation of oil lakes in Kuwait at the end of the Gulf Wa/r. A laboratory testing program was carried out to determine the geotechnical properties of this material and the effect of aging on their properties. Tests included direct shear, triaxial, and consolidation tests on clean and contaminated sand at the same relative density. The influence of aging was examined by testing uncontaminated sand after aging for one, three, and six months in natural environmental conditions. The results indicated increased strength and stiffness due to aging and a reduction of the oil content due to evaporation of volatile compounds. The factors that influence the depth of oil penetration in compacted sand columns were also examined including the type of oil, relative density, and the amount of fines

  16. Treatability of volatile chlorinated hydrocarbon-contaminated soils of different textures along a vertical profile by mechanical soil aeration: A laboratory test.

    Science.gov (United States)

    Ma, Yan; Shi, Yi; Hou, Deyi; Zhang, Xi; Chen, Jiaqi; Wang, Zhifen; Xu, Zhu; Li, Fasheng; Du, Xiaoming

    2017-04-01

    Mechanical soil aeration is a simple, effective, and low-cost soil remediation technology that is suitable for sites contaminated with volatile chlorinated hydrocarbons (VCHs). Conventionally, this technique is used to treat the mixed soil of a site without considering the diversity and treatability of different soils within the site. A laboratory test was conducted to evaluate the effectiveness of mechanical soil aeration for remediating soils of different textures (silty, clayey, and sandy soils) along a vertical profile at an abandoned chloro-alkali chemical site in China. The collected soils were artificially contaminated with chloroform (TCM) and trichloroethylene (TCE). Mechanical soil aeration was effective for remediating VCHs (removal efficiency >98%). The volatilization process was described by an exponential kinetic function. In the early stage of treatment (0-7hr), rapid contaminant volatilization followed a pseudo-first order kinetic model. VCH concentrations decreased to low levels and showed a tailing phenomenon with very slow contaminant release after 8hr. Compared with silty and sandy soils, clayey soil has high organic-matter content, a large specific surface area, a high clay fraction, and a complex pore structure. These characteristics substantially influenced the removal process, making it less efficient, more time consuming, and consequently more expensive. Our findings provide a potential basis for optimizing soil remediation strategy in a cost-effective manner. Copyright © 2016. Published by Elsevier B.V.

  17. Character and levels of radioactive contamination of underground waters at Semipalatinsk test site

    Energy Technology Data Exchange (ETDEWEB)

    Subbotin, S.; Lukashenko, S.; Turchenko, Y. [Institute of radiation safety and ecology (Kazakhstan)

    2014-07-01

    According to the data of RK government commission, 470 explosions have been set off at the Semipalatinsk Test Site (STS), inclusive of 26 surface, 90 in the air and 354 underground nuclear explosions (UNE), 103 of those have been conducted in tunnels and 251 - in boreholes. Underground nuclear explosions have been conducted at STS in horizontal mines, called - 'tunnels' ('Degelen' test site) and vertical mines called 'boreholes' ('Balapan' and 'Sary-Uzen' test sites). Gopher cavities of boreholes and tunnels are in different geotechnical conditions, that eventually specify migration of radioactive products with underground waters. Central cavities of UNE in holes are located significantly below the level of distribution of underground water. High temperature remains for a long time due to presence of overlying rock mass. High temperatures contribute to formation of thermal convection. When reaching the cavity, the water heat up, dissolve chemical elements and radionuclides and return with them to the water bearing formation. In the major part of 'Balapan' site for underground water of regional basin is characterized by low concentrations of radionuclides. High concentrations of {sup 137}Cs in underground water have been found only in immediate vicinity to 'warfare' boreholes. Formation of radiation situation in the 'Balapan' test site area is also affected by local area of underground water discharge. It is located in the valley of Shagan creek, where the concentration of {sup 3}H reaches 700 kBq/l. Enter of underground water contaminated with tritium into surface water well continue. In this case it is expected that tritium concentration in discharge zone can significantly change, because this migration process depends on hydro geological factors and the amount of atmospheric precipitation. Central cavities of nuclear explosions, made in tunnels, are above the level of underground

  18. Prevention of the wind migration of Semipalatinsk test site contaminated topsoil by inter-polymer complexes

    International Nuclear Information System (INIS)

    Kudaibergenov, S.E.

    2010-01-01

    Full text: It is well known that Semipalatinsk Test Site has been contaminated by radionuclides mainly as a result of atmospheric, aboveground and underground intensive nuclear tests during more than 40 years. Survey of residual radioactivity in the soil at ten Semipalatinsk Test Site areas showed that a great number of Plutonium-239, 240, Strontium-90 and Cesium-137 are concentrated in the depth of soil layer 0-8 cm. The residual radioactivity within the Semipalatinsk Test Site is tightly bound to the topsoil as a result of extreme heating and melting of the soils during the tests. The maximal amount of radionuclides is accumulated on the fine soil particles having 0.1-1.0 mm size. Wind erosion is responsible for suspension of contaminated soil particles in the air and further spreading of contamination far away. For instance, dust particles of diameter 0,05-0,1 mm are dropped within a couple of kilometers of the erosion site, while particles of about 0.005-0.01 mm diameter can move hundreds and thousands of kilometers. According to the results of the Institute of Radiation Safety and Ecology, Kazakhstan, in “Degelen” massive, where the intensive nuclear tests were carried out, the concentration of radionuclides in air increases for Sr-90 up to 5 times, for Pu-239,240 up to 100-250 times during the elevation of thin dust from the ground surface. In this connection agglomeration of thin dust containing radionuclides is of primary importance to protect the population from inhalation of re-suspended dust. Inter-polymer complexes are water-insoluble, moisture and gas permeable substances that form a “cobweb” on the surface of soil particles and consequently leading to formation of protective crust. Inter-polymer complexes enhance the intrusion of water into the soil, resulting in increased soil moisture to promote seed germination and plant growth. Inter-polymer complexes are also able to accumulate radionuclides via inclusion of metal ions into the Inter

  19. Radiological Risk Assessment and Survey of Radioactive Contamination for Foodstuffs

    International Nuclear Information System (INIS)

    Lee, W.R.; Lee, C.W.; Choi, K.S.

    2007-11-01

    After the Chernobyl nuclear accident in 1986, a radiological dose assessment and a survey of a radioactive contamination for foodstuffs have been investigated by many countries such as EU, Japan, USA. In the case of Japan which is similar to our country for the imported regions of foodstuffs, there were some instances of the excess for regulation on the maximum permitted levels of radioactive contamination among some imported foodstuffs. Concerns about the radioactive contamination of foodstuffs are increased because of the recently special situation (Nuclear test of North Korea). The purpose of this study is a radiological dose assessment and a survey of a radioactive contamination for foodstuffs in order to reduce the probability of intake of contaminated foodstuffs. Analytical results of the collected samples are below MDA. In this project, the model of radiological dose assessment via the food chain was also developed and radiological dose assessment was conducted based on surveys results of a radioactive contamination for foodstuffs in the Korean open markets since 2002. The results of radiological dose assessment are far below international reference level. It shows that public radiation exposure via food chain is well controlled within the international guide level. However, the radioactive contamination research of imported foodstuffs should be continuous considering the special situation(nuclear test of North Korea). These results are used to manage the radioactive contamination of the imported foodstuffs and also amend the regulation on the maximum permitted levels of radioactive contamination of foodstuffs

  20. Field demonstrations of passive detectors for screening of alpha contaminated soils

    International Nuclear Information System (INIS)

    Meyer, K.E.; Gammage, R.B.; Dudney, C.S.

    1994-01-01

    There are numerous sites around the country, DOE and otherwise, that are faced with the daunting task of remediating radiologically contaminated soils and groundwaters. Some of these sites, such as the Nevada Test Site and the Rocky Flats Plant, have contaminants that have been dispersed over wide areas. The costs of the characterization phase alone for such remediation programs can be prohibitive. Therefore there are pressing needs for testing and evaluation of new technologies for screening for radiological contaminants that may offer significant advantages in capital costs, ease of use, sensitivity, ruggedness, and/or reliability. This work reports on laboratory and Field tests of two types of passive alpha detectors, electret ionization chambers (EIC's) and alpha track detectors (ATD's), that have been commercially developed for indoor radon measurements. Previous work documented calibration and measurement protocols developed for these detectors for indoor surface contamination measurements

  1. Earthworm avoidance test for soil assessments. An alternative for acute and reproduction tests

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K.; Wiechering, H. [Fraunhofer-Inst. fuer Umweltchemie und Oekotoxikologie, Schmallenberg (Germany)

    2001-07-01

    For ecotoxicological assessments of contaminated or remediated soils pointing to the habitat function of soils for biocenoses, standardized tests with earthworms (acute test, reproduction test) are available among others. Tests used for routine applications should be sensitive and indicate impacts on test organisms after short test periods. The usually applied earthworm tests do not satisfactorily fulfil these criteria. Therefore, in the present work, a behavioural test with earthworms (test criterion: avoidance) was investigated in detail using uncontaminated, artificially contaminated and originally contaminated soils. It was demonstrated that the avoidance behaviour is primarily determined by pollutants, and not by chemical-physical soil properties. The sensitivity of the presented test reaches the sensitivity of established tests. For waste sites, a considerably higher sensitivity was determined. An avoidance behaviour of at least 80% of the worms leaving the soil to be assessed is proposed as a criterion for toxicity. (orig.)

  2. Detection and reduction of tungsten contamination in ion implantation processes

    International Nuclear Information System (INIS)

    Polignano, M.L.; Galbiati, A.; Grasso, S.; Mica, I.; Barbarossa, F.; Magni, D.

    2016-01-01

    In this paper, we review the results of some studies addressing the problem of tungsten contamination in implantation processes. For some tests, the implanter was contaminated by implantation of wafers with an exposed tungsten layer, resulting in critical contamination conditions. First, DLTS (deep level transient spectroscopy) measurements were calibrated to measure tungsten contamination in ion-implanted samples. DLTS measurements of tungsten-implanted samples showed that the tungsten concentration increases linearly with the dose up to a rather low dose (5 x 10 10 cm -2 ). Tungsten deactivation was observed when the dose was further increased. Under these conditions, ToF-SIMS revealed tungsten at the wafer surface, showing that deactivation was due to surface segregation. DLTS calibration could therefore be obtained in the linear dose regime only. This calibration was used to evaluate the tungsten contamination in arsenic implantations. Ordinary operating conditions and critical contamination conditions of the equipment were compared. A moderate tungsten contamination was observed in samples implanted under ordinary operating conditions. This contamination was easily suppressed by a thin screen oxide. On the contrary, implantations in critical conditions of the equipment resulted in a relevant tungsten contamination, which could be reduced but not suppressed even by a relatively thick screen oxide (up to 150 Aa). A decontamination process consisting of high dose implantations of dummy wafers was tested for its efficiency to remove tungsten and titanium contamination. This process was found to be much more effective for titanium than for tungsten. Finally, DLTS proved to be much more sensitive that TXRF (total reflection X-ray fluorescence) in detecting tungsten contamination. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  3. Detection and reduction of tungsten contamination in ion implantation processes

    Energy Technology Data Exchange (ETDEWEB)

    Polignano, M.L.; Galbiati, A.; Grasso, S.; Mica, I.; Barbarossa, F.; Magni, D. [STMicroelectronics, Agrate Brianza (Italy)

    2016-12-15

    In this paper, we review the results of some studies addressing the problem of tungsten contamination in implantation processes. For some tests, the implanter was contaminated by implantation of wafers with an exposed tungsten layer, resulting in critical contamination conditions. First, DLTS (deep level transient spectroscopy) measurements were calibrated to measure tungsten contamination in ion-implanted samples. DLTS measurements of tungsten-implanted samples showed that the tungsten concentration increases linearly with the dose up to a rather low dose (5 x 10{sup 10} cm{sup -2}). Tungsten deactivation was observed when the dose was further increased. Under these conditions, ToF-SIMS revealed tungsten at the wafer surface, showing that deactivation was due to surface segregation. DLTS calibration could therefore be obtained in the linear dose regime only. This calibration was used to evaluate the tungsten contamination in arsenic implantations. Ordinary operating conditions and critical contamination conditions of the equipment were compared. A moderate tungsten contamination was observed in samples implanted under ordinary operating conditions. This contamination was easily suppressed by a thin screen oxide. On the contrary, implantations in critical conditions of the equipment resulted in a relevant tungsten contamination, which could be reduced but not suppressed even by a relatively thick screen oxide (up to 150 Aa). A decontamination process consisting of high dose implantations of dummy wafers was tested for its efficiency to remove tungsten and titanium contamination. This process was found to be much more effective for titanium than for tungsten. Finally, DLTS proved to be much more sensitive that TXRF (total reflection X-ray fluorescence) in detecting tungsten contamination. (copyright 2016 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Surgery for acquired cardiovascular disease: antiseptic treatment of contaminated vein grafts.

    Science.gov (United States)

    Schmidt, F P; Peivandi, A A; Kohnen, W; Jansen, B

    2014-04-01

    Saphenous vein grafts harvested for use as bypass conduits can be contaminated intraoperatively, e.g. by being inadvertently dropped to the floor of the operating room (OR). This study was performed to investigate microorganisms most likely contaminating vein grafts and to assess the possible efficacy of measures to treat potentially contaminated vein grafts antiseptically for further use. In a first step we determined the microbiological flora of the OR using surface cultures and cultures from intentionally dropped vein grafts. Several antiseptic agents (PVP-iodine 10%, octenidinhydrochloride 0.1%, polyhexanide 1%) were evaluated for their in vitro efficacy to disinfect artificially contaminated vein segments. The most promising antiseptic regimen was tested on veins contaminated in a real OR setting. Finally, we tested for possible alterations in mechanical properties of the veins caused by antiseptic treatment. Coagulase-negative staphylococci where the predominant bacteria recovered from the OR with 59.9%. Antiseptic treatment with a combination of octenidine and PVP-iodine resulted in a higher rate of negative cultures than any single agent. Treatment of 50 saphenous vein grafts contaminated in the OR with the combination regimen resulted in only 3 positive cultural results within 7 days. Mechanical tear-stress testing comparing antiseptically treated vein grafts with controls showed no difference in their resistance to tear stress. Antiseptic treatment of contaminated vein grafts was shown to be effective in a high percentage of cases without altering mechanical properties of grafts and may be an option for the surgeon in case of a contamination.

  5. Regenerable Air Purification System for Gas-Phase Contaminant Control

    Science.gov (United States)

    Constantinescu, Ileana C.; Finn, John E.; LeVan, M. Douglas; Lung, Bernadette (Technical Monitor)

    2000-01-01

    Tests of a pre-prototype regenerable air purification system (RAPS) that uses water vapor to displace adsorbed contaminants from an adsorbent column have been performed at NASA Ames Research Center. A unit based on this design can be used for removing trace gas-phase contaminants from spacecraft cabin air or from polluted process streams including incinerator exhaust. During the normal operation mode, contaminants are removed from the air on the column. Regeneration of the column is performed on-line. During regeneration, contaminants are displaced and destroyed inside the closed oxidation loop. In this presentation we discuss initial experimental results for the performance of RAPS in the removal and treatment of several important spacecraft contaminant species from air.

  6. Leaching of PFC from soils contaminated with PFC of different origin

    Science.gov (United States)

    Kalbe, Ute; Piechotta, Christian; Rothe, Robert

    2017-04-01

    Leaching tests are fundamental tools for the assessment of groundwater impact by contaminated soils concerning the soil-groundwater pathway. Such procedures are supposed to serve as the basis for a reliable leachate prognosis. They can be applied to determine the short and long term leaching behaviour as well as the source term of contaminated soils. For this purpose two types of leaching procedures have been validated in Germany for the examination of the leaching behaviour of frequently occurring organic substances (DIN 19528 - column test and DIN 19529 - batch test). A liquid-to-solid ratio (L/S) of 2 L/kg and 10 L/kg) is the basis for the risk assessment which is implemented in different German regulations. The equivalence of test results for both tests for the same material under investigation has been investigated for a variety of pollutants in order to assess their reliability in compliance testing. However, for emerging pollutants there is hardly data available on this issue. Leaching tests on soils contaminated with emerging pollutants such as PFC (Perfluorinated Surfactants) are currently coming more into consideration due to the increasing detection of contaminated sites. Therefore, two soils were investigated in this study from different contamination source (paper sludge containing compost and fire distinguishing foam) using both leaching tests and both liquid-to-solid ratios. The leachability of the various perfluorinated compounds in relation to their content in solid matter was considered. Furthermore the eluate pre-treatment prior analysis (in particular liquid/solid separation step needed for batch tests) has been taken into account. The comparability of the results from batch and column is dependent on the solubility of the various compounds, on the L/S and on the turbidity in the eluates.

  7. Test plan for glove box testing with the real-time transuranic dust monitor

    International Nuclear Information System (INIS)

    Partin, J.K.; Fincke, J.R.

    1994-10-01

    This test plan describes the objectives, instrumentation, and testing procedures used to prove the feasibility of a real-time transuranic dust monitor (RTDM). The RTDM is under development at the Idaho National Engineering Laboratory (INEL) as a Waste Characterization Technology funded by the Buried Waste Integrated Demonstration Project. The instrument is an in situ monitor that uses optical techniques to establish particle size, particle number density, and mass and species of heavy metal contamination. US Department of Energy orders mandate the assessment of radiological exposure and contamination spread during the remediation of radioactive waste. Of particular concern is heavy metal contamination of dust, both radioactive and nonradioactive. Small particles of metal, particularly the radioactive species, tend to become electrically charged and consequently attach themselves to dust particles. This airborne activated dust is a primary means of contamination transport during remediation activities, and therefore, must be continuously monitored to protect personnel involved in the operations and to control the spread of contamination. If real-time monitoring is not available there is increased likelihood of generating unacceptably high levels of contamination and being forced to shut down costly retrieval operations to decontaminate. A series of experiments are described to determine the optimal experimental design, operational parameters, and levels of detection for the RTDM. Initial screening will be performed using monodisperse particle standards to set parameters and calibrate the instrument. Additional testing will be performed using INEL soil samples spiked with a surrogate, cerium oxide, to prove the design before transporting the apparatus to the Test Reactor Area for testing with plutonium-contaminated dusts

  8. Tracer-level radioactive pilot-scale test of in situ vitrification technology for the stabilization of contaminated soil sites at ORNL

    International Nuclear Information System (INIS)

    Jacobs, G.K.; Spalding, B.P.

    1991-11-01

    This plan summarizes the activities to be performed during FY 1990 and FY 1991 for the tracer-level radioactive pilot-scale in situ vitrification (ISV) test. This test is the second step in evaluating ISV as a remedial action for the pits and trenches at Oak Ridge National Laboratory (ORNL). A previous test used nonradioactive tracers for cesium and strontium. This new test will again use a one-half-scale model of trench 7 and the pilot-scale ISV equipment of Pacific Northwest Laboratory (PNL). A small and precisely known amount of waste from a liquid waste disposal pit will be used for the test. An actually contaminated waste site cannot be used for this test because of the necessity to use an exactly known inventory of radionuclides so that a precise measurement of the volatilization of various constituents to the off-gas can be determined

  9. Radioactive contamination of oil produced from nuclear-broken shale

    International Nuclear Information System (INIS)

    Arnold, W.D.; Crouse, D.J.

    1970-01-01

    The results of small-scale exposure and retorting tests indicate that oil recovered from shale that has been broken with nuclear explosives will be contaminated with tritium. When oil shale was heated in sealed flasks with tritiated water vapor or with tritiated hydrogen, both the shale and the oil subsequently retorted from the shale contained tritium. There was much less contamination of the shale or oil, however, when the shale was exposed to tritiated methane and ethane. Contamination of shale and oil with tritium, as the result, of exposure to tritiated water, increased as the exposure temperature, exposure pressure, and the tritium concentration in the water were increased. This contamination also increased as the exposure time was increased up to 25 days, but not significantly thereafter. More than 90% of the tritium was removed from contaminated shale by treating the shale with moist air at elevated temperatures. Only small amounts of the tritium were removed from crude oil by contacting it with solid drying agents or with water. When tritium-contaminated shale oil was distilled, the tritium contents of the recovered fractions were found to be approximately equal. After being heated with a sample of underground test-shot debris, liquid shale oil became contaminated with radioactive fission products. Most of the radioactivity of the oil was due to finely dispersed solids rather than to dissolved radionuclides. Filtration of the oil removed a major fraction of the radioactive material. When the contaminated oil was distilled, more than 99% of the radionuclides remained in the pot residue. (author)

  10. Radioactive contamination of oil produced from nuclear-broken shale

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, W D; Crouse, D J

    1970-05-15

    The results of small-scale exposure and retorting tests indicate that oil recovered from shale that has been broken with nuclear explosives will be contaminated with tritium. When oil shale was heated in sealed flasks with tritiated water vapor or with tritiated hydrogen, both the shale and the oil subsequently retorted from the shale contained tritium. There was much less contamination of the shale or oil, however, when the shale was exposed to tritiated methane and ethane. Contamination of shale and oil with tritium, as the result, of exposure to tritiated water, increased as the exposure temperature, exposure pressure, and the tritium concentration in the water were increased. This contamination also increased as the exposure time was increased up to 25 days, but not significantly thereafter. More than 90% of the tritium was removed from contaminated shale by treating the shale with moist air at elevated temperatures. Only small amounts of the tritium were removed from crude oil by contacting it with solid drying agents or with water. When tritium-contaminated shale oil was distilled, the tritium contents of the recovered fractions were found to be approximately equal. After being heated with a sample of underground test-shot debris, liquid shale oil became contaminated with radioactive fission products. Most of the radioactivity of the oil was due to finely dispersed solids rather than to dissolved radionuclides. Filtration of the oil removed a major fraction of the radioactive material. When the contaminated oil was distilled, more than 99% of the radionuclides remained in the pot residue. (author)

  11. Modeling contaminant plumes in fractured limestone aquifers

    DEFF Research Database (Denmark)

    Mosthaf, Klaus; Brauns, Bentje; Fjordbøge, Annika Sidelmann

    Determining the fate and transport of contaminant plumes from contaminated sites in limestone aquifers is important because they are a major drinking water resource. This is challenging because they are often heavily fractured and contain chert layers and nodules, resulting in a complex transport...... model. The paper concludes with recommendations on how to identify and employ suitable models to advance the conceptual understanding and as decision support tools for risk assessment and the planning of remedial actions....... behavior. Improved conceptual models are needed for this type of site. Here conceptual models are developed by combining numerical models with field data. Several types of fracture flow and transport models are available for the modeling of contaminant transport in fractured media. These include...... the established approaches of the equivalent porous medium, discrete fracture and dual continuum models. However, these modeling concepts are not well tested for contaminant plume migration in limestone geologies. Our goal was to develop and evaluate approaches for modeling the transport of dissolved contaminant...

  12. Technology for reuse of contaminated concrete constituents

    International Nuclear Information System (INIS)

    Binkhorst, I.P.; Cornelissen, H.A.W.

    1998-01-01

    During decommissioning activities of nuclear installations, large amounts of contaminated concrete will have to be processed. All this concrete has to be treated and stored as radioactive waste, which implies major economical and environmental consequences. It was shown that the contamination is mainly concentrated in the porous cement stone. By separating this cement stone from the clean dense aggregate particles, a considerable volume reduction can be reached. KEMA has developed, designed and constructed a pilot plant scale test installation for separation of aggregate from contaminated concrete. The separation is based on a thermal treatment followed by milling and sieving. The clean aggregate can be re-used in concrete, whereas the (slightly) contaminated cement stone could be upgraded to a binder for concrete used in the nuclear industry. (author)

  13. Automatic personnel contamination monitor

    International Nuclear Information System (INIS)

    Lattin, Kenneth R.

    1978-01-01

    United Nuclear Industries, Inc. (UNI) has developed an automatic personnel contamination monitor (APCM), which uniquely combines the design features of both portal and hand and shoe monitors. In addition, this prototype system also has a number of new features, including: micro computer control and readout, nineteen large area gas flow detectors, real-time background compensation, self-checking for system failures, and card reader identification and control. UNI's experience in operating the Hanford N Reactor, located in Richland, Washington, has shown the necessity of automatically monitoring plant personnel for contamination after they have passed through the procedurally controlled radiation zones. This final check ensures that each radiation zone worker has been properly checked before leaving company controlled boundaries. Investigation of the commercially available portal and hand and shoe monitors indicated that they did not have the sensitivity or sophistication required for UNI's application, therefore, a development program was initiated, resulting in the subject monitor. Field testing shows good sensitivity to personnel contamination with the majority of alarms showing contaminants on clothing, face and head areas. In general, the APCM has sensitivity comparable to portal survey instrumentation. The inherit stand-in, walk-on feature of the APCM not only makes it easy to use, but makes it difficult to bypass. (author)

  14. Residual risk of bacterial contamination of platelets: six years of experience with sterility testing.

    Science.gov (United States)

    Ramirez-Arcos, Sandra; DiFranco, Caesar; McIntyre, Terri; Goldman, Mindy

    2017-09-01

    Canadian Blood Services screens 100% of platelet concentrates (PCs) for bacterial contamination with the BacT/ALERT system. Quality-control sterility testing of 1% (≥10 units) of outdated PCs is performed monthly. Data from routine screening, quality-control testing, and septic reactions obtained from 2010 to 2016 are presented herein. In total, 601,988 buffy coat PC pools and 186,737 apheresis PCs were routinely screened with aerobic cultures over 6 years. Outdate quality-control testing of 8535 buffy coat and 8498 apheresis PCs was performed using aerobic and anaerobic cultures during the same period. Results were classified as "true-positives" when the same bacterium was isolated in initial and confirmatory cultures or "false-negatives" when bacteria were missed in early screening and were captured during quality-control sterility testing or through investigation of sepsis cases. During routine screening, the true-positive rates between buffy coat (0.94 per 10,000) and apheresis (0.96 per 10,000) PCs were similar (p = 0.9473). Seventy-five bacteria isolated during PC screening included Gram-positive and Gram-negative organisms. Six false-negative septic reactions were reported that implicated coagulase-negative staphylococci (n = 3) and Staphylococcus aureus (n = 3) for approximate rates of 1 per 100,000 transfusion reactions and 1 per 500,000 fatalities. During quality-control testing, the false-negative rates between buffy coat (8 per 10,000) and apheresis (9 per 10,000) PCs were similar (p = 0.7897). All 15 quality-control isolates were Gram-positive bacteria. The current bacterial screening protocol is efficacious for identifying Gram-negative bacteria. However, the high proportion of Gram-positive organisms detected on outdate quality-control testing and septic transfusion events demonstrates a residual safety risk that merits further intervention. © 2017 AABB.

  15. 9 CFR 113.42 - Detection of lymphocytic choriomeningitis contamination.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false Detection of lymphocytic choriomeningitis contamination. 113.42 Section 113.42 Animals and Animal Products ANIMAL AND PLANT HEALTH... contamination. The test for detection of lymphocytic choriomeningitis (LCM) virus provided in this section shall...

  16. Effect of various coal contaminants on the performance of solid oxide fuel cells: Part I. Accelerated testing

    Energy Technology Data Exchange (ETDEWEB)

    Bao, JianEr; Krishnan, Gopala N.; Jayaweera, Palitha; Perez-Mariano, Jordi; Sanjurjo, Angel [SRI International, 333 Ravenswood Ave, Menlo Park, CA 94025 (United States)

    2009-09-05

    The contaminants that are potentially present in the coal-derived gas stream and their thermochemical nature are discussed. Accelerated testing was carried out on Ni-YSZ/YSZ/LSM solid oxide fuel cells (YSZ: yttria stabilized zirconia and LSM: lanthanum strontium manganese oxide) for eight main kind of contaminants: CH{sub 3}Cl, HCl, As, P, Zn, Hg, Cd and Sb at the temperature range of 750-850 C. The As and P species, at 10 and 35 ppm, respectively, resulted in severe power density degradation at temperatures 800 C and below. SEM and EDX analysis indicated that As attacked the Ni region of the anode surface and the Ni current collector, caused the break of the current collector and the eventual cell failure at 800 C. The phosphorous containing species were found in the bulk of the anode, they were segregated and formed ''grain boundary'' like phases separating large Ni patches. These species are presumably nickel phosphide/phosphate and zirconia phosphate, which could break the Ni network for electron transport and inhibit the YSZ network for oxygen ion transport. The presence of 40 ppm CH{sub 3}Cl and 5 ppm Cd only affected the cell power density at above 800 C and Cd caused significant performance loss. Whereas the presence of 9 ppm Zn, 7 ppm Hg and 8 ppm Sb only degraded the cell power density by less than 1% during the 100 h test in the temperature range of 750-850 C. (author)

  17. Sediment and toxic contaminant transport modeling in coastal waters

    International Nuclear Information System (INIS)

    Onishi, Yasuo; Mayer, D.W.; Argo, R.S.

    1982-01-01

    Models are presented to estimate the migration of toxic contaminants in coastal waters. Ocean current is simulated by the vertically-averaged, finite element, two-demensional model known as CAFE-I with the Galerkin weighted residual technique. The refraction of locally generated waves or swells is simulated by the wave refraction model, LO3D. Using computed current, depth, and wave characteristics, the finite element model, FETRA, simulated sediment and contaminant transport in coastal waters, estuaries and rivers. Prior to the application of these models to the Irish Sea and other coastal waters, the finite element model, FETRA, was tested to demonstrate its ability to simulate sediment and contaminant interaction, and the mechanism governing the transport, deposition, and resuspension of contaminated sediment. Several simple equations such as the unsteady, advection-diffusion equation, the equation for noncohesive-sediment load due to wind-induced waves in offshore and surf zones, and the equation for sediment-radionuclide transport simulation were solved during the preliminary testing of the model. (Kato, T.)

  18. Radioactive contamination in monitors received for calibration

    International Nuclear Information System (INIS)

    Dias, Paulo S.; Santos, Gilvan C. dos; Brunelo, Maria Antonieta G.; Paula, Tiago C. de; Pires, Marina A.; Borges, Jose C.

    2013-01-01

    The Calibration Laboratory - LABCAL, from the Research Center for Metrology and Testing - METROBRAS, MRA Comercio de Instrumentos Eletronicos Ltda., began activities in October 2008 and, in August 2009, decided to establish a procedure for monitoring tests, external and internal, of all packages received from customers, containing instruments for calibration. The aim was to investigate possible contamination radioactive on these instruments. On July 2011, this procedure was extended to packagings of personal thermoluminescent dosemeters - TLD, received by the newly created Laboratory Laboratorio de Dosimetria Pessoal - LDP . In the monitoring procedure were used monitors with external probe, type pancake, MRA brand, models GP - 500 and MIR 7028. During the 37 months in which this investigation was conducted, were detected 42 cases of radioactive contamination, with the following characteristics: 1) just one case was personal dosimeter, TLD type; 2) just one case was not from a packing from nuclear medicine service - was from a mining company; 3) contamination occurred on packs and instruments, located and/or widespread; 4) contamination values ranged from slightly above the level of background radiation to about a thousand fold. Although METROBRAS has facilities for decontamination, in most cases, especially those of higher contamination, the procedure followed was to store the contaminated material in a room used for storage of radioactive sources. Periodically, each package and/or instrument was monitored, being released when the radiation level matched the background radiation. Every contamination detected, the client and/or owner of the instrument was informed. The Brazilian National Energy Commission - CNEN, was informed, during your public consultation for reviewing the standard for nuclear medicine services, held in mid-2012, having received from METROBRAS the statistical data available at the time. The high frequency of contamination detected and the high

  19. Dynamic Sampling of Trace Contaminants During the Mission Operations Test of the Deep Space Habitat

    Science.gov (United States)

    Monje, Oscar; Valling, Simo; Cornish, Jim

    2013-01-01

    The atmospheric composition inside spacecraft during long duration space missions is dynamic due to changes in the living and working environment of crew members, crew metabolism and payload operations. A portable FTIR gas analyzer was used to monitor the atmospheric composition within the Deep Space Habitat (DSH) during the Mission Operations Test (MOT) conducted at the Johnson Space Center (JSC). The FTIR monitored up to 20 gases in near- real time. The procedures developed for operating the FTIR were successful and data was collected with the FTIR at 5 minute intervals. Not all the 20 gases sampled were detected in all the modules and it was possible to measure dynamic changes in trace contaminant concentrations that were related to crew activities involving exercise and meal preparation.

  20. Light Obscuration Particle Counter Fuel Contamination Limits

    Science.gov (United States)

    2015-10-08

    two methods for measuring particulate contamination by gravimetric analysis: ASTM D2276 - Standard Test Method for Particulate Contaminant in Aviation...problems with the gravimetric methods is the poor repeatability and reproducibility of the methods , ASTM D2276 has a repeatability of 0.25 mg/L and...collected failing either the particle count or the gravimetric limit, 314 of which failed both methods . 245 false negatives were recorded where the

  1. Bonding of radioactive contamination. III. Auger electron spectroscopic investigation

    International Nuclear Information System (INIS)

    Rankin, W.N.; Whitkop, P.G.

    1983-01-01

    The mechanisms by which radioactive contamination would be bonded to a DWPF canister surface are being investigated. Tests with low pressure water and air-injected water decontamination of radioactive specimens showed that bonding of contamination increases rapidly with postoxidation temperature. Even with the least severe temperature conditions expected on the waste glass canister, bonding is so great that decontamination cannot be affected by water-only techniques. A preoxidation film increased rather than decreased bonding. This memorandum describes detailed surface analyses of coupons simulating DWPF canister surfaces. Based on this examination we conclude: contamination will be dispersed throughout the oxide film on DWPF canisters. Contamination is concentrated at the surface, decreasing farther into the oxide film; some samples contain sludge contamination at the steel/oxide interface. This was not the case for semi-volatile (Cs 2 O) contamination; in samples with contamination at the steel/oxide interface, at least 80% of the contamination is usually in the oxide layer; no difference in contamination dispersion between preoxidized and non-preoxidized samples was found; and postoxidation atmosphere had no effect on the contamination dispersion within the oxide layer. 6 references, 9 figures

  2. Methods for removing radioactive isotopes from contaminated streams

    International Nuclear Information System (INIS)

    Hoy, D.R.; Hickey, T.N.; Spulgis, I.S.; Parish, H.C.

    1979-01-01

    Methods for removing radioactive isotopes from contaminated gas streams for use in atmospheric containment and cleanup systems in nuclear power plants are provided. The methods provide for removal of radioactive isotopes from a first portion of the contaminated stream, separated from the remaining portion of the stream, so that adsorbent used to purify the first portion of the contaminated stream by adsorption of the radioactive isotopes therefrom can be tested to determine the adsorbing efficacy of the generally larger portion of adsorbent used to purify the remaining portion of the stream

  3. Active airborne contamination control using electrophoresis

    International Nuclear Information System (INIS)

    Veatch, B.D.

    1994-01-01

    In spite of our best efforts, radioactive airborne contamination continues to be a formidable problem at many of the Department of Energy (DOE) weapons complex sites. For workers that must enter areas with high levels of airborne contamination, personnel protective equipment (PPE) can become highly restrictive, greatly diminishing productivity. Rather than require even more restrictive PPE for personnel in some situations, the Rocky Flats Plant (RFP) is actively researching and developing methods to aggressively combat airborne contamination hazards using electrophoretic technology. With appropriate equipment, airborne particulates can be effectively removed and collected for disposal in one simple process. The equipment needed to implement electrophoresis is relatively inexpensive, highly reliable, and very compact. Once airborne contamination levels are reduced, less PPE is required and a significant cost savings may be realized through decreased waste and maximized productivity. Preliminary ''cold,'' or non-radioactive, testing results at the RFP have shown the technology to be effective on a reasonable scale, with several potential benefits and an abundance of applications

  4. Corrective Action Decision Document for Corrective Action Unit 168: Area 25 and 26 Contaminated Materials and Waste Dumps, Nevada Test Site, Nevada, Rev. No.: 2 with Errata Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Wickline, Alfred

    2006-12-01

    This Corrective Action Decision Document has been prepared for Corrective Action Unit (CAU) 168: Area 25 and 26, Contaminated Materials and Waste Dumps, Nevada Test Site, Nevada. The purpose of this Corrective Action Decision Document is to identify and provide a rationale for the selection of a recommended corrective action alternative for each corrective action site (CAS) within CAU 168. The corrective action investigation (CAI) was conducted in accordance with the ''Corrective Action Investigation Plan for Corrective Action Unit 168: Area 25 and 26, Contaminated Materials and Waste Dumps, Nevada Test Site, Nevada'', as developed under the ''Federal Facility Agreement and Consent Order'' (1996). Corrective Action Unit 168 is located in Areas 25 and 26 of the Nevada Test Site, Nevada and is comprised of the following 12 CASs: CAS 25-16-01, Construction Waste Pile; CAS 25-16-03, MX Construction Landfill; CAS 25-19-02, Waste Disposal Site; CAS 25-23-02, Radioactive Storage RR Cars; CAS 25-23-13, ETL - Lab Radioactive Contamination; CAS 25-23-18, Radioactive Material Storage; CAS 25-34-01, NRDS Contaminated Bunker; CAS 25-34-02, NRDS Contaminated Bunker; CAS 25-99-16, USW G3; CAS 26-08-01, Waste Dump/Burn Pit; CAS 26-17-01, Pluto Waste Holding Area; and CAS 26-19-02, Contaminated Waste Dump No.2. Analytes detected during the CAI were evaluated against preliminary action levels (PALs) to determine contaminants of concern (COCs) for CASs within CAU 168. Radiological measurements of railroad cars and test equipment were compared to unrestricted (free) release criteria. Assessment of the data generated from the CAI activities revealed the following: (1) Corrective Action Site 25-16-01 contains hydrocarbon-contaminated soil at concentrations exceeding the PAL. The contamination is at discrete locations associated with asphalt debris. (2) No COCs were identified at CAS 25-16-03. Buried construction waste is present in at least two

  5. In situ remediation of chlorinated solvent-contaminated groundwater using ZVI/organic carbon amendment in China: field pilot test and full-scale application.

    Science.gov (United States)

    Yang, Jie; Meng, Liang; Guo, Lin

    2018-02-01

    Chlorinated solvents in groundwater pose threats to human health and the environment due to their carcinogenesis and bioaccumulation. These problems are often more severe in developing countries such as China. Thus, methods for chlorinated solvent-contaminated groundwater remediation are urgently needed. This study presents a technique of in situ remediation via the direct-push amendment injection that enhances the reductive dechlorination of chlorinated solvents in groundwater in the low-permeability aquifer. A field-based pilot test and a following real-world, full-scale application were conducted at an active manufacturing facility in Shanghai, China. The chlorinated solvents found at the clay till site included 1,1,1-trichloroethane (1,1,1-TCA), 1,1-dichloroethane (1,1-DCA), 1,1-dichloroethylene (1,1-DCE), vinyl chloride (VC), and chloroethane (CA). A commercially available amendment (EHC ® , Peroxychem, Philadelphia, PA) combining zero-valent iron and organic carbon was used to treat the above pollutants. Pilot test results showed that direct-push EHC injection efficiently facilitated the in situ reductive remediation of groundwater contaminated with chlorinated solvents. The mean removal rates of 1,1,1-TCA, 1,1-DCA, and 1,1-DCE at 270 days post-injection were 99.6, 99.3, and 73.3%, respectively, which were obviously higher than those of VC and CA (42.3 and 37.1%, respectively). Clear decreases in oxidation-reduction potential and dissolved oxygen concentration, and increases in Fe 2+ and total organic carbon concentration, were also observed during the monitoring period. These indicate that EHC promotes the anaerobic degradation of chlorinated hydrocarbons primarily via long-term biological reductive dechlorination, with instant chemical reductive dechlorination acting as a secondary pathway. The optimal effective time of EHC injection was 0-90 days, and its radius of influence was 1.5 m. In full-scale application, the maximum concentrations of 1,1,1-TCA

  6. Contaminant Leach Testing of Hanford Tank 241-C-104 Residual Waste

    Energy Technology Data Exchange (ETDEWEB)

    Cantrell, Kirk J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Snyder, Michelle M.V. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Guohui [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Buck, Edgar C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-07-01

    Leach testing of Tank C-104 residual waste was completed using batch and column experiments. Tank C-104 residual waste contains exceptionally high concentrations of uranium (i.e., as high as 115 mg/g or 11.5 wt.%). This study was conducted to provide data to develop contaminant release models for Tank C-104 residual waste and Tank C-104 residual waste that has been treated with lime to transform uranium in the waste to a highly insoluble calcium uranate (CaUO4) or similar phase. Three column leaching cases were investigated. In the first case, C-104 residual waste was leached with deionized water. In the second case, crushed grout was added to the column so that deionized water contacted the grout prior to contacting the waste. In the third case, lime was mixed in with the grout. Results of the column experiments demonstrate that addition of lime dramatically reduces the leachability of uranium from Tank C-104 residual waste. Initial indications suggest that CaUO4 or a similar highly insoluble calcium rich uranium phase forms as a result of the lime addition. Additional work is needed to definitively identify the uranium phases that occur in the as received waste and the waste after the lime treatment.

  7. DSCOVR Contamination Lessons Learned

    Science.gov (United States)

    Graziani, Larissa

    2015-01-01

    The Triana observatory was built at NASA GSFC in the late 1990's, then placed into storage. After approximately ten years it was removed from storage and repurposed as the Deep Space Climate Observatory (DSCOVR). This presentation outlines the contamination control program lessons learned during the integration, test and launch of DSCOVR.

  8. Urban community gardeners' knowledge and perceptions of soil contaminant risks.

    Science.gov (United States)

    Kim, Brent F; Poulsen, Melissa N; Margulies, Jared D; Dix, Katie L; Palmer, Anne M; Nachman, Keeve E

    2014-01-01

    Although urban community gardening can offer health, social, environmental, and economic benefits, these benefits must be weighed against the potential health risks stemming from exposure to contaminants such as heavy metals and organic chemicals that may be present in urban soils. Individuals who garden at or eat food grown in contaminated urban garden sites may be at risk of exposure to such contaminants. Gardeners may be unaware of these risks and how to manage them. We used a mixed quantitative/qualitative research approach to characterize urban community gardeners' knowledge and perceptions of risks related to soil contaminant exposure. We conducted surveys with 70 gardeners from 15 community gardens in Baltimore, Maryland, and semi-structured interviews with 18 key informants knowledgeable about community gardening and soil contamination in Baltimore. We identified a range of factors, challenges, and needs related to Baltimore community gardeners' perceptions of risk related to soil contamination, including low levels of concern and inconsistent levels of knowledge about heavy metal and organic chemical contaminants, barriers to investigating a garden site's history and conducting soil tests, limited knowledge of best practices for reducing exposure, and a need for clear and concise information on how best to prevent and manage soil contamination. Key informants discussed various strategies for developing and disseminating educational materials to gardeners. For some challenges, such as barriers to conducting site history and soil tests, some informants recommended city-wide interventions that bypass the need for gardener knowledge altogether.

  9. Urban community gardeners' knowledge and perceptions of soil contaminant risks.

    Directory of Open Access Journals (Sweden)

    Brent F Kim

    Full Text Available Although urban community gardening can offer health, social, environmental, and economic benefits, these benefits must be weighed against the potential health risks stemming from exposure to contaminants such as heavy metals and organic chemicals that may be present in urban soils. Individuals who garden at or eat food grown in contaminated urban garden sites may be at risk of exposure to such contaminants. Gardeners may be unaware of these risks and how to manage them. We used a mixed quantitative/qualitative research approach to characterize urban community gardeners' knowledge and perceptions of risks related to soil contaminant exposure. We conducted surveys with 70 gardeners from 15 community gardens in Baltimore, Maryland, and semi-structured interviews with 18 key informants knowledgeable about community gardening and soil contamination in Baltimore. We identified a range of factors, challenges, and needs related to Baltimore community gardeners' perceptions of risk related to soil contamination, including low levels of concern and inconsistent levels of knowledge about heavy metal and organic chemical contaminants, barriers to investigating a garden site's history and conducting soil tests, limited knowledge of best practices for reducing exposure, and a need for clear and concise information on how best to prevent and manage soil contamination. Key informants discussed various strategies for developing and disseminating educational materials to gardeners. For some challenges, such as barriers to conducting site history and soil tests, some informants recommended city-wide interventions that bypass the need for gardener knowledge altogether.

  10. Contaminant resorption during soil washing

    International Nuclear Information System (INIS)

    Gombert, D.

    1993-01-01

    To evaluate the applicability of soil washing to a specific site requires some basic research in how contaminants are bound. Much can be learned from sequential extraction methodology based on micronutrient bioavailability studies wherein the soil matrix is chemically dissected to selectively remove particular fixation mechanisms independently. This procedure uses a series of progressively more aggressive solvents to dissolve the principle phases that make up a soil, however, the published studies do not appear to consider the potential for a contaminant released from one type of site to resorb on another site during an extraction. This physical model assumes no ion exchange or adsorption at sites either previously occupied by other ions, or exposed by the dissolution. Therefore, to make engineering use of the sequential extraction data, the release of contamination must be evaluated relative to the effects of resorption. Time release studies were conducted to determine the optimum duration for extraction to maximize complete destruction of the target matrix fraction while minimizing contaminant resorption. Tests with and without a potassium brine present to inhibit cesium resorption indicated extraction efficiency could be enhanced by as much as a factor of ten using the brine

  11. Present situation of radioactive contamination in and around the former Soviet Union's Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Yamamoto, M.; Hoshi, M.; Takada, J.; Tsukatani, T.; Oikawa, S.; Yoshikawa, I.; Takatsuji, T.; Sekerbaev, A. Kh.; Gusev, B.I.

    2001-01-01

    Field missions were sent to the Semipalatinsk regions to investigate the present radioecological situation as a result of the radioactive fallout from nuclear test explosions carried out at the former Soviet Union's Semipalatinsk nuclear test site (SNTS). For this purpose, surface and core soil samples were collected at more than 60 sites, including several settlements such as Dolon, Chagan and Sarzhal, within and outside the SNTS territory. The radioactivities of long-lived radionuclides, 137 Cs, 238 Pu and 239,240 Pu, and the atomic ratio of 240 Pu/ 239 Pu were determined in combination with non-destructive g-ray spectrometric method and radiochemical separation followed by a-particle spectrometric and/or ICP-MS methods. The results showed a distinction of 137 Cs and 239,240 Pu inventories in soil depending on a sampling sites. Although 137 Cs was within typical environmental levels except for the area near the first nuclear test site and Balapan, 239,240 Pu was at elevated levels in all areas we visited. This high Pu contamination was recognized to be due to the weapons-grade Pu from the SNTS by the measurement of 240 Pu/ 239P u atomic ratio in soil samples. (author)

  12. Non-tenera Contamination and the Economic Impact of SHELL Genetic Testing in the Malaysian Independent Oil Palm Industry.

    Science.gov (United States)

    Ooi, Leslie C-L; Low, Eng-Ti L; Abdullah, Meilina O; Nookiah, Rajanaidu; Ting, Ngoot C; Nagappan, Jayanthi; Manaf, Mohamad A A; Chan, Kuang-Lim; Halim, Mohd A; Azizi, Norazah; Omar, Wahid; Murad, Abdul J; Lakey, Nathan; Ordway, Jared M; Favello, Anthony; Budiman, Muhammad A; Van Brunt, Andrew; Beil, Melissa; Leininger, Michael T; Jiang, Nan; Smith, Steven W; Brown, Clyde R; Kuek, Alex C S; Bahrain, Shabani; Hoynes-O'Connor, Allison; Nguyen, Amelia Y; Chaudhari, Hemangi G; Shah, Shivam A; Choo, Yuen-May; Sambanthamurthi, Ravigadevi; Singh, Rajinder

    2016-01-01

    Oil palm (Elaeis guineensis) is the most productive oil bearing crop worldwide. It has three fruit forms, namely dura (thick-shelled), pisifera (shell-less) and tenera (thin-shelled), which are controlled by the SHELL gene. The fruit forms exhibit monogenic co-dominant inheritance, where tenera is a hybrid obtained by crossing maternal dura and paternal pisifera palms. Commercial palm oil production is based on planting thin-shelled tenera palms, which typically yield 30% more oil than dura palms, while pisifera palms are female-sterile and have little to no palm oil yield. It is clear that tenera hybrids produce more oil than either parent due to single gene heterosis. The unintentional planting of dura or pisifera palms reduces overall yield and impacts land utilization that would otherwise be devoted to more productive tenera palms. Here, we identify three additional novel mutant alleles of the SHELL gene, which encode a type II MADS-box transcription factor, and determine oil yield via control of shell fruit form phenotype in a manner similar to two previously identified mutant SHELL alleles. Assays encompassing all five mutations account for all dura and pisifera palms analyzed. By assaying for these variants in 10,224 mature palms or seedlings, we report the first large scale accurate genotype-based determination of the fruit forms in independent oil palm planting sites and in the nurseries that supply them throughout Malaysia. The measured non-tenera contamination rate (10.9% overall on a weighted average basis) underscores the importance of SHELL genetic testing of seedlings prior to planting in production fields. By eliminating non-tenera contamination, comprehensive SHELL genetic testing can improve sustainability by increasing yield on existing planted lands. In addition, economic modeling demonstrates that SHELL gene testing will confer substantial annual economic gains to the oil palm industry, to Malaysian gross national income and to Malaysian

  13. Contamination risk of stable isotope samples during milling.

    Science.gov (United States)

    Isaac-Renton, M; Schneider, L; Treydte, K

    2016-07-15

    Isotope analysis of wood is an important tool in dendrochronology and ecophysiology. Prior to mass spectrometry analysis, wood must be homogenized, and a convenient method involves a ball mill capable of milling samples directly in sample tubes. However, sample-tube plastic can contaminate wood during milling, which could lead to biological misinterpretations. We tested possible contamination of whole wood and cellulose samples during ball-mill homogenization for carbon and oxygen isotope measurements. We used a multi-factorial design with two/three steel milling balls, two sample amounts (10 mg, 40 mg), and two milling times (5 min, 10 min). We further analyzed abrasion by milling empty tubes, and measured the isotope ratios of pure contaminants. A strong risk exists for carbon isotope bias through plastic contamination: the δ(13) C value of polypropylene deviated from the control by -6.77‰. Small fibers from PTFE filter bags used during cellulose extraction also present a risk as the δ(13) C value of this plastic deviated by -5.02‰. Low sample amounts (10 mg) showed highest contamination due to increased abrasion during milling (-1.34‰), which is further concentrated by cellulose extraction (-3.38‰). Oxygen isotope measurements were unaffected. A ball mill can be used to homogenize samples within test tubes prior to oxygen isotope analysis, but not prior to carbon or radiocarbon isotope analysis. There is still a need for a fast, simple and contamination-free sample preparation procedure. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Minimum detectable activities of contamination control survey equipment

    International Nuclear Information System (INIS)

    Goles, R.W.; Baumann, B.L.; Johnson, M.L.

    1991-08-01

    The Instrumentation ampersand External Dosimetry (I ampersand ED) Section of the Health Physics Department at the Pacific Northwest Laboratory (PNL) has performed a series of tests to determine the ability of portable survey instruments used at Hanford to detect radioactive contamination at levels required by DOE 5480.11. This semi-empirical study combines instrumental, statistical, and human factors as necessary to derive operational detection limits. These threshold detection values have been compared to existing contamination control requirements, and detection deficiencies have been identified when present. Portable survey instruments used on the Hanford Site identify the presence of radioactive surface contamination based on the detection of α-, β-, γ-, and/or x-radiation. However, except in some unique circumstances, most contamination monitors in use at Hanford are configured to detect either α-radiation alone or β- and γ-radiation together. Testing was therefore conducted on only these two categories of radiation detection devices. Nevertheless, many of the results obtained are generally applicable to all survey instruments, allowing performance evaluations to be extended to monitoring devices which are exclusively γ- and/or x-ray- sensitive. 6 figs., 2 tabs

  15. Plutonium-contaminated fragments at the Taranaki site at Maralinga

    International Nuclear Information System (INIS)

    Burns, P.A.; Cooper, M.B.; Duggleby, J.C.; Mika, J.F.; Williams, G.A.

    1986-07-01

    A detailed assessment is presented of the distribution of plutonium-contaminated fragments and sub-millimetre particles in the vicinity of the Taranaki site at the former U.K. Atomic Weapons Test Range at Maralinga in South Australia. The area which is contaminated with fragments has been divided into three general regions with the designations 'heavily contaminated', 'moderately contaminated' and 'plumes'. The average surface density, activity and estimated total number of fragments are presented for each region. Average surface densities of all fragments with americium-241 activities greater than 2 kBq are estimated to be 33, 7 and 2 m -2 for the 'heavily contaminated', 'moderately contaminated' and 'plumes' regions respectively. The total number of such fragments is estimated to be in excess of three million which accounts for a total plutonium activity of approximately 0.8 TBq. The implications of these results for a rehabilitation program are discussed

  16. Shear bond strength of orthodontic brackets and disinclusion buttons: effect of water and saliva contamination.

    Science.gov (United States)

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea

    2013-01-01

    The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  17. Toxicological evaluation of a lake ecosystem contaminated with crude oil

    International Nuclear Information System (INIS)

    Twigg, D.; Ramey, B.

    1995-01-01

    Winona Lake on the Daniel Boone National Forest in Powell County, Kentucky, was used from the mid 1950's to 1987 as a water source for water-injection oil drilling and as a brine disposal site. The lake was contaminated with excessive amounts of crude oil. A multi phase investigation was conducted, including chemical analysis of water and sediment, water toxicity tests using a cladoceran, Ceriodaphnia dubia, sediment toxicity tests using an amphipod, Hyalella azteca, and a faunal survey of the communities of the lake and stream both above and below the lake. The sediment was laden with petroleum hydrocarbons (4.1 parts per thousand), while the water showed no contamination. The C dubia test results showed no significant water toxicity. The contaminated sediment adjacent to the dam produced 75% mortality in H. azteca. The faunal survey indicated little or no impact on the upstream and downstream communities but the lake community was highly impacted, especially the benthos. Pollution tolerant Chaoborus sp. were the only organisms collected from sediment samples dredged from the lake. Contamination was limited to the sediment within the lake but the impact on the entire lake community was severe

  18. Contamination and decontamination of vehicles driven in radioactive areas

    International Nuclear Information System (INIS)

    Ulvsand, T.; Nygren, U.

    1999-03-01

    There is reason to ask whether it is beneficial to decontaminate vehicles, in view of the great effort applied. If the level of contamination is low before the decontamination process, then the cost is not motivated, even if the decontamination is shown to be effective in relative terms. The report describes two trials at the National NBC Defence School in Umeaa and one trial at the French test site in Bourges. The aim is to investigate how vehicles are contaminated and at which ground deposition levels troublesome levels of contamination will arise. In the trials, a non-radioactive agent substituting real radioactivity was used. The trials in Sweden so far have used the oversnow vehicle BV 206, during both winter and summer conditions. The vehicles were driven a specific distance along a road on which a known amount of the test substance had been dispersed. Samples were taken on pre-determined areas on one side of the vehicles to measure the amount of test substance. Later, the vehicles continued along a 'clean' road where additional samples were taken, but on the other side of the vehicles. The largest amount of test substance was collected on the tracks and on the back of the vehicle. The tracks and mud-flaps were effectively decontaminated when the vehicles were driven along a clean road, while most of the contamination remained on the backside. The purpose of the trials in France was to compare the results from our non-radioactive and their radioactive method, based on the radioactive La-140. Due to ground conditions, the level of contamination on the vehicles was much less than in the trials in Umeaa, but the effect decontamination could be measured after all

  19. Th biodistribution in internal contamination of animals

    International Nuclear Information System (INIS)

    Ciubotariu, M.; Danis, A.; Dumitrescu, G.; Cucu, M.

    1999-01-01

    body from a non-contaminated rat and a solution calibrated in Th. The obtained results put into evidence that the Th was retained in all the vital organs of the contaminated rats, particularly in lung, liver, stomach and small intestine. All the contaminated rats have presented a non-uniform Th distribution in the investigated organs excepting the one which was sacrificed 2 days after contamination. In its organs Th inclusions were present. Their Th concentration were ranging from 1 ppm up to 24 ppm. We think that the rejection reaction of the contaminant element by the rats organism was stronger on the first days after contamination and, as a consequence, the Th was gathered in inclusions, as 'intruder' element. In time, these inclusions were 'washed' by blood and then eliminated. From the point of view of the medical state, the blood test revealed the normal values of the hemoglobin and a exponential increase of the leucocyte values (leucocytosis) without toxic granules in comparison with the U internal contamination where the blood test revealed granular cytopenia and acute leukopenia with toxic granules. In the next stage, we shall try to find a correlation between the ingested Th amount and the ones retained and eliminated by rats. For that, we must investigate the Th elimination through urine and excrements. We must specify that our results obtained in the studies on the U or Th internal contamination can be used only as a discussion based in order to think out a plan for a systematic biological investigation on the internal contamination in which a sufficient number of subjects must be used for a good statistics. (authors)

  20. Estimation of radioactive contamination of soils from the “Balapan” and the “Experimental field” technical areas of the Semipalatinsk nuclear test site

    International Nuclear Information System (INIS)

    Evseeva, T.; Belykh, E.; Geras’kin, S.; Majstrenko, T.

    2012-01-01

    In spite of the long history of the research, radioactive contamination of the Semipalatinsk nuclear test site (SNTS) in the Republic of Kazakhstan has not been adequately characterized. Our cartographic investigation has demonstrated highly variable radioactive contamination of the SNTS. The Cs-137, Sr-90, Eu-152, Eu-154, Co-60, and Am-241 activity concentrations in soil samples from the “Balapan” site were 42.6–17646, 96–18250, 1.05–11222, 0.6–4865, 0.23–4893, and 1.2–1037 Bq kg −1 , correspondingly. Cs-137 and Sr-90 activity concentrations in soil samples from the “Experimental field” site were varied from 87 up to 400 and from 94 up to 1000 Bq kg −1 , respectively. Activity concentrations of Co-60, Eu-152, and Eu-154 were lower than the minimum detectable activity of the method used. Concentrations of naturally occurring radionuclides (K-40, Ra-226, U-238, and Th-232) in the majority of soil samples from the “Balapan” and the “Experimental field” sites did not exceed typical for surrounding of the SNTS areas levels. Estimation of risks associated with radioactive contamination based on the IAEA clearance levels for a number of key radionuclides in solid materials shows that soils sampled from the 'Balapan' and the “Experimental field” sites might be considered as radioactive wastes. Decrease in specific activity of soil from the sites studied up to safety levels due to Co-60, Cs-137, Sr-90, Eu-152, Eu-154 radioactive decay and Am-241 accumulation-decay will occur not earlier than 100 years. In contrast, soils from the “Experimental field” and the “Balapan” sites (except 0.5–2.5 km distance from the “Chagan” explosion point) cannot be regarded as the radioactive wastes according safety norms valid in Russia and Kazakhstan. - Highlights: ► Distribution of radionuclides in soil of Semipalatinsk test site was mapped. ► The main contributors into soil radioactive contamination were 137 Cs and 90 Sr. ► Soils

  1. Evaluation of food contamination and health risks caused by radioactive fallout released from atmospheric nuclear detonation tests

    International Nuclear Information System (INIS)

    Shimada, Yoko; Ito, Yoshihiko; Yoneda, Minoru; Morisawa, Shinsuke

    2011-01-01

    Before Fukushima Daiichi nuclear disaster, radionuclide like 137 Cs released from atmospheric nuclear detonation tests and Chernobyl disaster has been transported worldwide in the environment and finally taken up by humans through various pathways. In this research, dietary intake of 137 Cs and the related health risks to Japanese caused by chronic global radioactive food contamination from 1945 to 2010 were evaluated by using the mathematical model for the evaluation of global distribution of 137 Cs with food ingestion and domestic and international food supply model. The results of this evaluation can show a background situation before Fukushima disaster and give important information for the risk assessment of this disaster. (author)

  2. Annotated bibliography of literature relating to wind transport of plutonium-contaminated soils at the Nevada Test Site

    International Nuclear Information System (INIS)

    Lancaster, N.; Bamford, R.

    1993-12-01

    During the period from 1954 through 1963, a number of tests were conducted on the Nevada Test Site (NTS) and Tonopah Test Range (TTR) to determine the safety of nuclear devices with respect to storage, handling, transport, and accidents. These tests were referred to as ''safety shots.'' ''Safety'' in this context meant ''safety against fission reaction.'' The safety tests were comprised of chemical high explosive detonations with components of nuclear devices. The conduct of these tests resulted in the dispersion of plutonium, and some americium over areas ranging from several tens to several hundreds of hectares. Of the various locations used for safety tests, the site referred to as ''Plutonium Valley'' was subject to a significant amount of plutonium contamination. Plutonium Valley is located in Area 11 on the eastern boundary of the NTS at an elevation of about 1036 m (3400 ft). Plutonium Valley was the location of four safety tests (A,B,C, and D) conducted during 1956. A major environmental, health, and safety concern is the potential for inhalation of Pu 239,240 by humans as a result of airborne dust containing Pu particles. Thus, the wind transport of Pu 239,240 particles has been the subject of considerable research. This annotated bibliography was created as a reference guide to assist in the better understanding of the environmental characteristics of Plutonium Valley, the safety tests performed there, the processes and variables involved with the wind transport of dust, and as an overview of proposed clean-up procedures

  3. Calculational Tool for Skin Contamination Dose Assessment

    CERN Document Server

    Hill, R L

    2002-01-01

    Spreadsheet calculational tool was developed to automate the calculations preformed for dose assessment of skin contamination. This document reports on the design and testing of the spreadsheet calculational tool.

  4. Radiation contamination monitors

    International Nuclear Information System (INIS)

    Kato, Tsutomu; Iba, Hiroshi; Sato, Hiroshi

    1999-01-01

    To make sure of no contamination on people, used articles and working uniforms coming out of the radiation controlled area, nuclear power plants are equipped with radioactive contamination monitors. This paper outlines the basic specifications and advantages of our personnel surface contamination monitors to inspect whole-body surface contamination of people coming out, article surface contamination monitors to inspect the surface and inside contamination of used articles brought out, laundry monitors to inspect surface contamination of working uniforms used in the area before and after a wash, and whole-body counters to inspect and measure the internal contamination of a person out of the area. (author)

  5. Airborne soil particulates as vehicles for Salmonella contamination of tomatoes.

    Science.gov (United States)

    Kumar, Govindaraj Dev; Williams, Robert C; Al Qublan, Hamzeh M; Sriranganathan, Nammalwar; Boyer, Renee R; Eifert, Joseph D

    2017-02-21

    The presence of dust is ubiquitous in the produce growing environment and its deposition on edible crops could occur. The potential of wind-distributed soil particulate to serve as a vehicle for S. Newport transfer to tomato blossoms and consequently, to fruits, was explored. Blossoms were challenged with previously autoclaved soil containing S. Newport (9.39log CFU/g) by brushing and airborne transfer. One hundred percent of blossoms brushed with S. Newport-contaminated soil tested positive for presence of the pathogen one week after contact (PCompressed air was used to simulate wind currents and direct soil particulates towards blossoms. Airborne soil particulates resulted in contamination of 29% of the blossoms with S. Newport one week after contact. Biophotonic imaging of blossoms post-contact with bioluminescent S. Newport-contaminated airborne soil particulates revealed transfer of the pathogen on petal, stamen and pedicel structures. Both fruits and calyxes that developed from blossoms contaminated with airborne soil particulates were positive for presence of S. Newport in both fruit (66.6%) and calyx (77.7%). Presence of S. Newport in surface-sterilized fruit and calyx tissue tested indicated internalization of the pathogen. These results show that airborne soil particulates could serve as a vehicle for Salmonella. Hence, Salmonella contaminated dust and soil particulate dispersion could contribute to pathogen contamination of fruit, indicating an omnipresent yet relatively unexplored contamination route. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Estimating contaminant discharge rates from stabilized uranium tailings embankments

    International Nuclear Information System (INIS)

    Weber, M.F.

    1986-01-01

    Estimates of contaminant discharge rates from stabilized uranium tailings embankments are essential in evaluating long-term impacts of tailings disposal on groundwater resources. Contaminant discharge rates are a function of water flux through tailings covers, the mass and distribution of tailings, and the concentrations of contaminants in percolating pore fluids. Simple calculations, laboratory and field testing, and analytical and numerical modeling may be used to estimate water flux through variably-saturated tailings under steady-state conditions, which develop after consolidation and dewatering have essentially ceased. Contaminant concentrations in water discharging from the tailings depend on tailings composition, leachability and solubility of contaminants, geochemical conditions within the embankment, tailings-water interactions, and flux of water through the embankment. These concentrations may be estimated based on maximum reported concentrations, pore water concentrations, extrapolations of column leaching data, or geochemical equilibria and reaction pathway modeling. Attempts to estimate contaminant discharge rates should begin with simple, conservative calculations and progress to more-complicated approaches, as necessary

  7. In situ treatability test plan

    International Nuclear Information System (INIS)

    1996-08-01

    This document describes the plans for the in situ treatment zone (ISTZ) treatability test for groundwater contaminated with strontium-90. The treatability test is to be conducted at the Hanford Site in Richland, Washington, in a portion of the 100-N Area adjacent to the Columbia River referred to as N-Springs. The purpose of the treatability test is to evaluate the effectiveness of an innovative technology to prevent the discharge of strontium-90 contaminated groundwater into the Columbia River. The ISTZ is a passive technology that consists of placing a treatment agent in the path of the groundwater. The treatment agent must restrict target radioactive contaminants and provide time for the contaminant to decay to acceptable levels. The permeability of the treatment zone must be greater than or equal to that of the surrounding sediments to ensure that the contaminated groundwater flows through the treatment zone agent and not around the agent

  8. An investigation of the possibility to replace the rabbit pyrogen test by an in vitro test

    NARCIS (Netherlands)

    Gommer AM; Donders LAM; LGM

    1998-01-01

    The classical test for the detection of pyrogenic contaminations in pharmaceuticals is the rabbit pyrogen test. The most frequently occuring and most important pyrogenic contamination in biological and biotechnological pharmaceutical preparations are bacterial endotoxins, originating from the

  9. Semipalatinsk test site: Parameters of radionuclide transfer to livestock and poultry products under actual radioactive contamination

    Energy Technology Data Exchange (ETDEWEB)

    Baigazinov, Z.; Lukashenko, S. [Institute of Radiation Safety and Ecology (Kazakhstan)

    2014-07-01

    The IAEA document 'Handbook of Parameter Values for the Prediction of Radionuclide Transfer in Terrestrial and Freshwater Environments' published in 2010 is one of the major sources of knowledge about the migration parameters of radionuclides in the agro-ecosystems that is necessary to assess the dose loads to the population. It is known from there that Sr and Cs transfer has been studied thoroughly, however the factors vary over a wide range. Few studies were conducted for Pu and Am transfer. It should be noted that the studies carried out in real conditions of radioactive contamination, i.e. under natural conditions is also very few. In this regard, since 2007 the territory of the former Semipalatinsk Test Site has been used for comprehensive radioecological studies, where the major radionuclides to be investigated are {sup 90}Sr, {sup 137}Cs, {sup 239+240}Pu, {sup 241}Am. The objects for these studies are birds and animals typical for the region, as well as products obtained from them (lamb, beef, horse meat, chicken, pork, cow's milk, mare's milk, eggs, chicken, chicken feathers, wool, leather). It should be noted that these products are the main agricultural goods that are available in these areas. The studies have been conducted with grazing animals in the most contaminated areas of the test site. Some groups of animals and birds were fed to contaminated feed, soil, contaminated water. Radionuclide intake by animal body with air were studied. Husbandry periods for animals and birds ranged from 1 to 150 days. The transfer parameters to cow and mare's milk have been investigated at single and prolonged intake of radionuclides, also their excretion dynamics has been studied. The studies revealed features of the radionuclide transfer into organs and tissues of animals and birds intaken with hay, water and soil. The results showed that the transfer factors vary up to one order. A relationship has been identified between distribution of

  10. Contamination tracer testing with seabed drills: IODP Expedition 357

    Science.gov (United States)

    Orcutt, Beth N.; Bergenthal, Markus; Freudenthal, Tim; Smith, David; Lilley, Marvin D.; Schnieders, Luzie; Green, Sophie; Früh-Green, Gretchen L.

    2017-11-01

    IODP Expedition 357 utilized seabed drills for the first time in the history of the ocean drilling program, with the aim of collecting intact sequences of shallow mantle core from the Atlantis Massif to examine serpentinization processes and the deep biosphere. This novel drilling approach required the development of a new remote seafloor system for delivering synthetic tracers during drilling to assess for possible sample contamination. Here, we describe this new tracer delivery system, assess the performance of the system during the expedition, provide an overview of the quality of the core samples collected for deep biosphere investigations based on tracer concentrations, and make recommendations for future applications of the system.

  11. Variability in physical contamination assessment of source segregated biodegradable municipal waste derived composts.

    Science.gov (United States)

    Echavarri-Bravo, Virginia; Thygesen, Helene H; Aspray, Thomas J

    2017-01-01

    Physical contaminants (glass, metal, plastic and 'other') and stones were isolated and categorised from three finished commercial composts derived from source segregated biodegradable municipal waste (BMW). A subset of the identified physical contaminant fragments were subsequently reintroduced into the cleaned compost samples and sent to three commercial laboratories for testing in an inter-laboratory trial using the current PAS100:2011 method (AfOR MT PC&S). The trial showed that the 'other' category caused difficulty for all three laboratories with under reporting, particularly of the most common 'other' contaminants (paper and cardboard) and, over-reporting of non-man-made fragments. One laboratory underreported metal contaminant fragments (spiked as silver foil) in three samples. Glass, plastic and stones were variably underreported due to miss-classification or over reported due to contamination with compost (organic) fragments. The results are discussed in the context of global physical contaminant test methods and compost quality assurance schemes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Sediment and toxic contaminant transport modeling in coastal waters

    International Nuclear Information System (INIS)

    Onishi, Y.; Mayer, D.W.; Argo, R.S.

    1982-02-01

    A hydrodynamic model, CAFE-I, a wave refraction model, LO3D, and a sediment and contaminant transport model, FETRA, were selected as tools for evaluating exposure levels of radionuclides, heavy metals, and other toxic chemicals in coastal waters. Prior to the application of these models to the Irish Sea and other coastal waters, the finite element model, FETRA, was tested to demonstrate its ability to simulate sediment and contaminant interactions (e.g., adsorption and desorption), and the mechanisms governing the transport, deposition, and resuspension of contaminated sediments

  13. Use of coal ash in production of concrete containing contaminated sand

    International Nuclear Information System (INIS)

    Ezeldin, A.S.

    1991-01-01

    There are between 2 to 3.5 million underground storage tanks located throughout the nation. Most of these tanks, which store oils and gasolines, are leaking making them one of the primary sources of soil contamination. Adding coal ash or cement to contaminated soil has been used to obtain stationary and inert wastecrete. By using this procedure, stabilization (limiting the solubility and mobility of the contaminants) and solidification (producing a solid waste block) of contaminated soils are successfully achieved. This paper investigates another re-use option of coal ash and contaminated soils. An experimental study evaluating the effectiveness of using coal ash with oil contaminated sand in concrete production is presented. A control mix made of clean sand was designed to yield 500 psi of compressive strength. Sand, artificially contaminated with 3% by weight of motor oil, was used as clean sand replacement. Six concrete mixtures were tested in compression and flexure. The six mixtures were obtained by increasing the ratio of contaminated sand to clean sand, namely; 10%, 20% and 40% and by introducing coal ash to the concrete mixture, namely; 20% of the cement weight. The test results indicate that the inclusion of oil contaminated sand in concrete reduces the compressive and flexural strengths. However, this decrease in strength is compensated by introducing coal ash in the mixture. Regaining that strength offers the possibility of using such concrete as a construction material in special structural applications. More research is required to establish better understanding of that composite and suggest feasible applications

  14. Rapid extraction of virus-contaminated hemocytes from oysters

    Science.gov (United States)

    Rapid viral detection methods are necessary to employ diagnostic testing for viral contamination in shellfish to prevent and control foodborne illness. Current shellfish viral RNA extraction methods, which are time-consuming and not applicable for routine monitoring, require the testing of whole or ...

  15. Comparison of solid-phase bioassays and ecoscores to evaluate the toxicity of contaminated soils

    Energy Technology Data Exchange (ETDEWEB)

    Lors, Christine [Universite Lille Nord de France, 1bis rue Georges Lefevre, 59044 Lille Cedex (France); Ecole des Mines de Douai, MPE-GCE, 941 rue Charles-Bourseul, 59500 Douai (France); Centre National de Recherche sur les Sites et Sols Pollues, 930 Boulevard Lahure, BP 537, 59505 Douai Cedex (France); Ponge, Jean-Francois, E-mail: ponge@mnhn.f [Museum National d' Histoire Naturelle, CNRS UMR 7179, 4 Avenue du Petit-Chateau, 91800 Brunoy (France); Martinez Aldaya, Maite [Museum National d' Histoire Naturelle, CNRS UMR 7179, 4 Avenue du Petit-Chateau, 91800 Brunoy (France); Damidot, Denis [Universite Lille Nord de France, 1bis rue Georges Lefevre, 59044 Lille Cedex (France); Ecole des Mines de Douai, MPE-GCE, 941 rue Charles-Bourseul, 59500 Douai (France)

    2010-08-15

    Five bioassays (inhibition of lettuce germination and growth, earthworm mortality, inhibition of springtail population growth, avoidance by springtails) were compared, using four coke factory soils contaminated by PAHs and trace elements, before and after biotreatment. For each bioassay, several endpoints were combined in an 'ecoscore', a measure of test sensitivity. Ecoscores pooled over all tested bioassays revealed that most organisms were highly sensitive to the concentration of 3-ring PAHs. When four soils were combined, behavioural tests using the springtail Folsomia candida showed higher ecoscores, i.e. they were most sensitive to soil contamination. However, despite overall higher sensitivity of behavioural tests, which could be used for cheap and rapid assessment of soil toxicity, especially at low levels of contamination, some test endpoints were more sensitive than others, and this may differ from a soil to another, pointing to the need for a battery of bioassays when more itemized results are expected. - The avoidance test using the soil springtail Folsomia candida is globally more sensitive to PAH contamination than acute and chronic toxicity bioassays using plants and animals but a battery of tests could reveal better in detail.

  16. Comparison of solid-phase bioassays and ecoscores to evaluate the toxicity of contaminated soils

    International Nuclear Information System (INIS)

    Lors, Christine; Ponge, Jean-Francois; Martinez Aldaya, Maite; Damidot, Denis

    2010-01-01

    Five bioassays (inhibition of lettuce germination and growth, earthworm mortality, inhibition of springtail population growth, avoidance by springtails) were compared, using four coke factory soils contaminated by PAHs and trace elements, before and after biotreatment. For each bioassay, several endpoints were combined in an 'ecoscore', a measure of test sensitivity. Ecoscores pooled over all tested bioassays revealed that most organisms were highly sensitive to the concentration of 3-ring PAHs. When four soils were combined, behavioural tests using the springtail Folsomia candida showed higher ecoscores, i.e. they were most sensitive to soil contamination. However, despite overall higher sensitivity of behavioural tests, which could be used for cheap and rapid assessment of soil toxicity, especially at low levels of contamination, some test endpoints were more sensitive than others, and this may differ from a soil to another, pointing to the need for a battery of bioassays when more itemized results are expected. - The avoidance test using the soil springtail Folsomia candida is globally more sensitive to PAH contamination than acute and chronic toxicity bioassays using plants and animals but a battery of tests could reveal better in detail.

  17. Contaminant levels in Gulf of Mexico reef fish after the Deepwater Horizon oil spill as measured by a fishermen-led testing program.

    Science.gov (United States)

    Fitzgerald, Timothy P; Gohlke, Julia M

    2014-01-01

    The BP oil disaster posed a significant threat to the U.S. seafood industry. Invertebrates (shrimp, oyster, crab) and other nearshore species comprised the majority of postspill testing by federal and state agencies. Deeper water finfish were sampled less frequently, despite population ranges that overlapped with affected waters. We report on a voluntary testing program with Gulf of Mexico commercial fishermen to ensure the safety of their catch. Seven species of reef fish were tested for polycyclic aromatic hydrocarbons, several metals, and a constituent of Corexit 9500A and 9527A dispersants. Only two of 92 samples had detectable levels of benzo(a)pyrene-equivalents (a combined measure of carcinogenic potency across 7 different PAHs), which were still below federal safety thresholds. PAH ratios for these samples suggest pyrogenic (not petrogenic) contamination - indicating potential sources other than Deepwater Horizon. Metals were largely absent (cadmium, lead) or consistent with levels previously reported (mercury, arsenic). One notable exception was tilefish, which showed mercury concentrations lower than expected. We did not detect dispersant in any of our samples, indicating that it was not present in these species during the study period. Our findings suggest minimal risk to public health from these seafoods as a result of the disaster; however, the most contaminated areas were not sampled through this program.

  18. study on trace contaminants control assembly for sealed environment chamber

    Science.gov (United States)

    Pang, L. P.; Wang, J.; Liu, L. K.; Liu, H.

    The biological and Physicochemical P C life support technologies are all important parts to establish a human Closed Ecological Life Support System CELSS for long-duration mission The latter has the advantages of lower power consumption lower mass and higher efficiency therefore researchers often incorporate the use of biological systems with P C life support technologies to continuously recycle air water and part of the solid waste stream generated such as the Russian BLSS and the NASA-sponsored Lunar-Mars Life Support Test Project LMLSTP In short these tests were very successful in integrating biological and P C life support technologies for long-duration life support Therefore we should use a combination of integrated biological with P C life support technologies in a human CELSS Human construction materials plants animals and soils release much trace toxic gases in a CELSS and they will inhibit plant growth and badly affect human health when their concentrations rise over their threshold levels The effect of biological trace contaminant control technologies is slower especially for a human sealed chamber because human produce much more methane and other contaminants A regenerative Trace Contaminant Control Subsystem TCCS with P C technology is a more important part in this case to control quickly the airborne contaminants levels and assure human in good condition in a sealed chamber This paper describes a trace contaminant control test facility incorporated a 8 m3 sealed environment chamber a regenerative TCCS with P C

  19. Grazing studies on a plutonium-contaminated range of the Nevada Test Site

    International Nuclear Information System (INIS)

    Smith, D.D.; Barth, J.; Patzer, R.G.

    1976-01-01

    A grazing study on a plutonium-contaminated range on the Nevada Test Site was initiated in May 1973 and is continuing. The primary objective of this study is to determine the uptake and tissue distribution of the plutonium by ruminants. Other objectives are to evaluate maternal-foetal transfer, to determine uptake and distribution differences in young versus mature animals, and to compare these data with those collected from other contaminated areas. Steers with surgically prepared rumen fistulas served as biological samplers to determine grazing habits (quantity and type of forage ingested) as a function of seasonal plant availability and preference, to estimate intake of actinides over specified periods of time, and to determine the actinide ratios within the ingesta. Since the study began tissue samples have been collected from seven cows, four calves, and three foetusses. All animals sacrificed were necropsied and selected tissue and organ samples collected for histo-pathological examination and actinide analyses. No significant lesions have been found and actinide accumulations in the tissues have been relatively minimal. Using activity levels found in the rumen contents of fistulated steers, it was estimated that a study cow ingested 100μCi prior to sacrifice. Of this, 16.4μCi was in rumen fluids from which a combined retention factor of 0.0034% was calculated for the bone, muscle and liver. Comparisons of 239 Pu/ 238 Pu ratios in ingesta and tissues indicate that the 238 Pu is more readily absorbed and retained. Analysis of ingesta from the fistulated steers indicates that grasses are preferred in the late spring and early summer months, with shrubs making up the bulk of the diet the rest of the year. Plutonium acitivity in rumen contents was higher when Eurotia lanata was the preferred shrub species. Studies on labelled particles indicate that ingested particles from 75 to 500μm in size have a half-time of 3.5 to 5 days in the intestinal tract, while

  20. Transfer of hydrophobic contaminants in urban runoff particles to benthic organisms estimated by an in vitro bioaccessibility test

    DEFF Research Database (Denmark)

    Nakajima, F.; Saito, K.; Isozaki, Y.

    2006-01-01

    An in vitro bioaccessibility test was applied for assessing the transfer of polycyclic aromatic hydrocarbons (PAHs) present in road dust, into benthic organisms living in a receiving water body. The road dust is supposed to be urban runoff particles under wet weather conditions. Sodium dodecyl...... sulfate (SDS) solution was used as a hypothetical gut fluid. Pyrene, fluoranthene and phenanthrene were the main PAH species in the SIDS extractable fraction of road dust, as well as the whole extract. Benzo(ghi)perylene showed relatively low concentrations in the SIDS extract in spite of a high...... concentration in the original dust. The PAH composition in benthic organisms (polychaetes) did not correspond with that of the surrounding sediment and the PAHs detected were also detected in high concentrations in the SDS extract of road dust. When testing the toxicity of the extracted contaminants...

  1. Removal factor determination of some local smear papers for surface contamination smear test

    International Nuclear Information System (INIS)

    Suratman; Indriyotomo, D.; Aminjoyo, S.

    1996-01-01

    Removal factor determination of some local smear papers has been done, using dry smear test method. The aim of this research is to find removal values of local smear papers on some surfaces, to replace import smear papers. Smear test was done on the various surfaces i.e.: porcelain, formica, glass, stainless steel, steel and PVC, with the local smear papers I.e.: Padalarang, Diagonal, Concorde, Marga, Hard Cloth, and import smear paper. The artificial contaminant which used were I-131 and P-32. The removal factor values of Padalarang paper for surfaces: porcelain, formica, glass stainless steel, steel and PVC were: 24.5%, 20.0%, 27.0%, 6.8%, 4.9%, and 13.6% respectively. The removal factor values of Diagonal paper were:18.4%, 15.9%, 5.7%, 3.5%, and 9.1% respectively. The removal factor values of concord paper were: 18.5%, 20.3%, 23.1%, 6.6%, 3.8%, and 9.0% respectively. The removal factor values of Marga paper were: 16.7%, 13.5%, 21.1%, 4.2%, 4.1% and 8.1% respectively. The removal factor values of Hard Cloth were: 18.6%, 12.6%, 20.5%, 8.2%, and 10.1% respectively. The removal factor values of import smear paper were: 17.8%, 15.0%, 18.8%, 9.1%, 4.8%, and 14.4% respectively . Substitution alternative of import smear paper is Padalarang. (author)

  2. 40 CFR 141.61 - Maximum contaminant levels for organic contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant levels for organic contaminants. 141.61 Section 141.61 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER... Regulations: Maximum Contaminant Levels and Maximum Residual Disinfectant Levels § 141.61 Maximum contaminant...

  3. Test and application of a general process-based dynamic coastal mass-balance model for contaminants using data for radionuclides in the Dnieper-Bug estuary

    International Nuclear Information System (INIS)

    Hakanson, Lars; Lindgren, Dan

    2009-01-01

    In this work a general, process-based mass-balance model for water contaminants for coastal areas at the ecosystem scale (CoastMab) is presented and for the first time tested for radionuclides. The model is dynamic, based on ordinary differential equations and gives monthly predictions. Connected to the core model there is also a sub-model for contaminant concentrations in fish. CoastMab calculates sedimentation, resuspension, diffusion, mixing, burial and retention of the given contaminant. The model contains both general algorithms, which apply to all contaminants, and substance-specific parts (such as algorithms for the particulate fraction, diffusion, biouptake and biological half-life). CoastMab and the sub-model for fish are simple to apply in practice since all driving variables may be readily accessed from maps or regular monitoring programs. The separation between the surface-water layer and the deep-water layer is not done as in most traditional models from water temperature data but from sedimentological criteria. Previous versions of the models for phosphorus and suspended particulate matter (in the Baltic Sea) have been validated and shown to predict well. This work presents modifications of the model and tests using two tracers, radiocesium and radiostrontium (from the Chernobyl fallout) in the Dnieper-Bug estuary (the Black Sea). Good correlations are shown between modeled and empirical data, except for the month directly after the fallout. We have, e.g., shown that: 1. The conditions in the sea outside the bay are important for the concentrations of the substances in water, sediments and fish within the bay, 2. We have demonstrated 'biological,' 'chemical' and 'water' dilution, 3. That the water chemical conditions in the bay influence biouptake and concentrations in fish of the radionuclides and 4. That the feeding behaviour of the coastal fish is very important for the biouptake of the radionuclides

  4. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    Science.gov (United States)

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola

    2013-01-01

    Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons. PMID:23762825

  5. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    Directory of Open Access Journals (Sweden)

    Maria Francesca Sfondrini

    2013-01-01

    Full Text Available Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a dry, (b water contamination, and (c saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values and Chi squared test (ARI Scores. Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  6. Forensic Luminol Blood Test for Preventing Cross-contamination in Dentistry: An Evaluation of a Dental School Clinic

    Directory of Open Access Journals (Sweden)

    Marcelo Carlos Bortoluzzi

    2014-01-01

    Conclusions: We suggest that the luminol method is suitable for identifying contamination with invisible blood traces and this method may be a useful tool to prevent cross-contamination in the dental care setting.

  7. Numerical Study of Contaminant Effects on Combustion of Hydrogen, Ethane, and Methane in Air

    Science.gov (United States)

    Lai, H. T.; Thomas, S. R.

    1995-01-01

    A numerical study was performed to assess the effects of vitiated air on the chemical kinetics of hydrogen, ethane, and methane combustion with air. A series of calculations in static reacting systems was performed, where the initial temperature was specified and reactions occurred at constant pressure. Three different types of test flow contaminants were considered: NP, H2O, and a combustion of H2O and CO2. These contaminants are present in the test flows of facilities used for hypersonic propulsion testing. The results were computed using a detailed reaction mechanism and are presented in terms of ignition and reaction times. Calculations were made for a wide range of contaminant concentrations, temperatures and pressures. The results indicate a pronounced kinetic effect over a range of temperatures, especially with NO contamination and, to a lesser degree, with H2O contamination. In all cases studied, CO2 remained kinetically inert, but had a thermodynamic effect on results by acting as a third body. The largest effect is observed with combustion using hydrogen fuel, less effect is seen with combustion of ethane, and little effect of contaminants is shown with methane combustion.

  8. Laboratory Evaluation of Light Obscuration Particle Counter Contamination Limits for Aviation Fuel

    Science.gov (United States)

    2015-11-01

    assurance testing though conducting periodic fuel sampling for gravimetric analysis. The Army currently utilizes two methods for measuring particulate...contamination by gravimetric analysis: ASTM D2276 - Standard Test Method for Particulate Contaminant in Aviation Fuel by Line Sampling, and ASTM D5452...while filter effectiveness is checked every 30 days by gravimetric analysis (ASTM D2276). One of the problems with the gravimetric methods is the

  9. The level of Escherichia coli contamination in foods and drinks sold at canteens campus

    Directory of Open Access Journals (Sweden)

    Dewi Susanna

    2011-02-01

    Full Text Available Background: Bacterial contamination is a common phenomenon in foods served in campus canteens and my cause physical illness which will affect academic activity. The aim of this study was to rank the level of Escherichia coli contamination in food and drink in campus canteens.Methods: Forty nine (49 foods and 24 types of drink were examined using conventional agar broth method for calculation of most probable number (MPN. The steps of the mothod were presumptive test for coliforms, fecal coliforms and E. coli, confirmes test for coliforms, fecal coli and E. coli and then completed test for E. coli. An analysis for contamination by E. coli in meals, utensils, and on the hands of the server was also undertaken. The data analyzed in percentage and rank all type of foods and drinks, also rank based on the location.Results: Almost all type of meals was contaminated. Meals with chili sauce were the most risky from the contamination of E. coli (90.15 %, then followed by dry meals (38.89%, while the wet meals were the the most unrisky meals. In  drinks, the highest was lacy juice, followed by jambu (guava juice, then Sirsak and Orange juices on the third rank, while the mango juice was the lowest contamination. Melon juice, cappucino and fruit-coctail did not have E. coli  contamination.Conclusion: The contamination in the top three rank of contamination could be from the utensils used and foodhandler. (Med J Indones 2011; 20:66-70Keywords: campus, canteen, drink, Escherichia coli, food

  10. Evaluation of Contamination Inspection and Analysis Methods through Modeling System Performance

    Science.gov (United States)

    Seasly, Elaine; Dever, Jason; Stuban, Steven M. F.

    2016-01-01

    Contamination is usually identified as a risk on the risk register for sensitive space systems hardware. Despite detailed, time-consuming, and costly contamination control efforts during assembly, integration, and test of space systems, contaminants are still found during visual inspections of hardware. Improved methods are needed to gather information during systems integration to catch potential contamination issues earlier and manage contamination risks better. This research explores evaluation of contamination inspection and analysis methods to determine optical system sensitivity to minimum detectable molecular contamination levels based on IEST-STD-CC1246E non-volatile residue (NVR) cleanliness levels. Potential future degradation of the system is modeled given chosen modules representative of optical elements in an optical system, minimum detectable molecular contamination levels for a chosen inspection and analysis method, and determining the effect of contamination on the system. By modeling system performance based on when molecular contamination is detected during systems integration and at what cleanliness level, the decision maker can perform trades amongst different inspection and analysis methods and determine if a planned method is adequate to meet system requirements and manage contamination risk.

  11. Contamination tracer testing with seabed drills: IODP Expedition 357

    Directory of Open Access Journals (Sweden)

    B. N. Orcutt

    2017-11-01

    Full Text Available IODP Expedition 357 utilized seabed drills for the first time in the history of the ocean drilling program, with the aim of collecting intact sequences of shallow mantle core from the Atlantis Massif to examine serpentinization processes and the deep biosphere. This novel drilling approach required the development of a new remote seafloor system for delivering synthetic tracers during drilling to assess for possible sample contamination. Here, we describe this new tracer delivery system, assess the performance of the system during the expedition, provide an overview of the quality of the core samples collected for deep biosphere investigations based on tracer concentrations, and make recommendations for future applications of the system.

  12. Contaminated concrete: Occurrence and emerging technologies for DOE decontamination

    International Nuclear Information System (INIS)

    Dickerson, K.S.; Wilson-Nichols, M.J.; Morris, M.I.

    1995-08-01

    The goals of the Facility Deactivation, Decommissioning, and Material Disposition Focus Area, sponsored by the US Department of Energy (DOE) Office of Technology Development, are to select, demonstrate, test, and evaluate an integrated set of technologies tailored to provide a complete solution to specific problems posed by deactivation, decontamination, and decommissioning, (D ampersand D). In response to these goals, technical task plan (TTP) OR152002, entitled Accelerated Testing of Concrete Decontamination Methods, was submitted by Oak Ridge National Laboratory. This report describes the results from the initial project tasks, which focused on the nature and extent of contaminated concrete, emerging candidate technologies, and matching of emerging technologies to concrete problems. Existing information was used to describe the nature and extent of contamination (technology logic diagrams, data bases, and the open literature). To supplement this information, personnel at various DOE sites were interviewed, providing a broad perspective of concrete contamination. Because characterization is in the initial stage at many sites, complete information is not available. Assimilation of available information into one location is helpful in identifying potential areas of concern in the future. The most frequently occurring radiological contaminants within the DOE complex are 137 Cs, 238 U (and it daughters), and 60 Co, followed closely by 90 Sr and tritium, which account for -30% of the total occurrence. Twenty-four percent of the contaminants were listed as unknown, indicating a lack of characterization information, and 24% were listed as other contaminants (over 100 isotopes) with less than 1% occurrence per isotope

  13. Contaminated concrete: Occurrence and emerging technologies for DOE decontamination

    Energy Technology Data Exchange (ETDEWEB)

    Dickerson, K.S.; Wilson-Nichols, M.J. [Oak Ridge National Lab., Grand Junction, CO (United States); Morris, M.I. [Oak Ridge National Lab., TN (United States)

    1995-08-01

    The goals of the Facility Deactivation, Decommissioning, and Material Disposition Focus Area, sponsored by the US Department of Energy (DOE) Office of Technology Development, are to select, demonstrate, test, and evaluate an integrated set of technologies tailored to provide a complete solution to specific problems posed by deactivation, decontamination, and decommissioning, (D&D). In response to these goals, technical task plan (TTP) OR152002, entitled Accelerated Testing of Concrete Decontamination Methods, was submitted by Oak Ridge National Laboratory. This report describes the results from the initial project tasks, which focused on the nature and extent of contaminated concrete, emerging candidate technologies, and matching of emerging technologies to concrete problems. Existing information was used to describe the nature and extent of contamination (technology logic diagrams, data bases, and the open literature). To supplement this information, personnel at various DOE sites were interviewed, providing a broad perspective of concrete contamination. Because characterization is in the initial stage at many sites, complete information is not available. Assimilation of available information into one location is helpful in identifying potential areas of concern in the future. The most frequently occurring radiological contaminants within the DOE complex are {sup 137}Cs, {sup 238}U (and it daughters), and {sup 60}Co, followed closely by {sup 90}Sr and tritium, which account for {minus}30% of the total occurrence. Twenty-four percent of the contaminants were listed as unknown, indicating a lack of characterization information, and 24% were listed as other contaminants (over 100 isotopes) with less than 1% occurrence per isotope.

  14. INCINERATION TREATMENT OF ARSENIC-CONTAMINATED SOIL

    Science.gov (United States)

    An incineration test program was conducted at the U.S. Environmental Protection Agency's Incineration Research Facility to evaluate the potential of incineration as a treatment option for contaminated soils at the Baird and McGuire Superfund site in Holbrook, Massachusetts. The p...

  15. Bio-Contamination Control for Spacesuit Garments - A Preliminary Study

    Science.gov (United States)

    Rhodes, Richard; Korona, Adam; Orndoff, Evelyn; Ott, Mark; Poritz, Darwin

    2010-01-01

    This paper outlines a preliminary study to review, test, and improve upon the current state of spacesuit bio-contamination control. The study includes an evaluation of current and advanced suit materials, ground and on-orbit cleaning methods, and microbial test and analysis methods. The first aspect of this study was to identify potential anti-microbial textiles and cleaning agents, and to review current microbial test methods. The anti-microbial cleaning agent and textile market survey included a review of current commercial-off-the-shelf (COTS) products that could potentially be used as future space flight hardware. This review included replacements for any of the softgood layers that may become contaminated during an extravehicular activity (EVA), including the pressure bladder, liquid cooling garment, and ancillary comfort undergarment. After a series of COTS anti-microbial textiles and clean ing agents were identified, a series of four tests were conducted: (1) a stacked configuration test that was conducted in order to review how bio-contamination would propagate through the various suit layers, (2) a individual materials test that evaluated how well each softgood layer either promoted or repressed growth, (3) a cleaning agent test that evaluated the efficacy on each of the baseline bladders, and (4) an evaluation of various COTS anti-microbial textiles. All antimicrobial COTS materials tested appeared to control bacteria colony forming unit (CFU) growth better than the Thermal Comfort Undergarment (TCU) and ACES Liquid Cooling Garment (LCG)/EMU Liquid Cooling Ventilation Garment (LCVG) materials currently in use. However, a comparison of fungi CFU growth in COTS to current suit materials appeared to vary per material. All cleaning agents tested in this study appeared to inhibit the level of bacteria and fungi growth to acceptable levels for short duration tests. While several trends can be obtained from the current analysis, a series of test improvements are

  16. Effect of salivary contamination on shear bond strength of two adhesives: An in vitro study

    Directory of Open Access Journals (Sweden)

    Shruti B Patil

    2014-01-01

    Full Text Available Introduction: Composite material used with bonding system are technique sensitive and contamination of an etched surface by saliva or blood plays a key role in bonding efficacy. Achieving good moisture control is a common problem encountered and is of importance while treating a pediatric age group since rubber dam in dental office is commonly applied in fewer than 10% of restorative treatment. Despite the advantage of rubber dam application, usage of rubber dam depends on child′s behavior and its level of co-operation for which pediatric dentists compromise with its usage. This study was conducted to evaluate the effect of salivary contamination of enamel and dentin on bond strength of two adhesives. Materials and Methods: An in vitro study comprised of test group of 112 central incisors divided into 4 groups for testing on enamel and dentin separately. These are Group I: Control group without salivary contamination; Group II: Contaminated with saliva and air-dried; Group III: Contaminated with saliva, rinsed and air-dried; Group IV: Coated with adhesive, light cured and then contaminated. Shear bond strength was calculated using universal testing machine. Results: For testing on enamel and dentin, significantly decreased bond strength was seen with Group II (P 0.05, when compared with control Group I. Conclusion: The decontamination method used in this study by rinsing the contaminated cured adhesive layer that did not reverse the harmful effect of salivary contamination. As most of the children are active and restless with swinging mood, it is important not to negotiate with the procedural steps during treatment.

  17. Nano-TiO2-based photocatalytic disinfection of environmental surfaces contaminated by meticillin-resistant Staphylococcus aureus.

    Science.gov (United States)

    Petti, S; Messano, G A

    2016-05-01

    Traditional cleaning and disinfection methods are inefficient for complete decontamination of hospital surfaces from meticillin-resistant Staphylococcus aureus (MRSA). Additional methods, such as nano-TiO2-based photocatalytic disinfection (PCD), could be helpful. To evaluate anti-MRSA activity of PCD on polyvinyl chloride (PVC) surfaces in natural-like conditions. Two identical PVC surfaces were used, and nano-TiO2 was incorporated into one of them. The surfaces were contaminated with MRSA isolated from hospitalized patients using a mist sprayer to simulate the mode of environmental contamination caused by a carrier. MRSA cell density was assessed before contamination until 180min after contamination using Rodac plates. The differences between test and control surfaces in terms of MRSA density and log MRSA density reduction were assessed using parametric and non-parametric statistical tests. Five strains were tested, and each strain was tested five times. The highest median MRSA densities [46.3 and 43.1 colony-forming units (cfu)/cm(2) for control and test surfaces, respectively] were detected 45min after contamination. Median MRSA densities 180min after contamination were 10.1 and 0.7cfu/cm(2) for control and test surfaces, respectively (Pdisinfectant activity remained stable throughout the 25 testing occasions, despite between-test cleaning and disinfection. The anti-MRSA activity of PCD was compatible with the benchmark for surface hygiene in hospitals (surfaces. However, for clinical surfaces, PCD should be regarded as supplemental to conventional decontamination procedures, rather than an alternative. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  18. Removal of residual contaminants in petroleum-contaminated soil by Fenton-like oxidation

    Energy Technology Data Exchange (ETDEWEB)

    Lu Mang [School of Material Science and Engineering, Jingdezhen Ceramic Institute, Jingdezhen, 333001, Jiangxi Province (China); State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249 (China); Zhang Zhongzhi, E-mail: zzzhang1955@hotmail.com [State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249 (China); Qiao Wei; Guan Yueming; Xiao Meng; Peng Chong [State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing 102249 (China)

    2010-07-15

    The degradation of bioremediation residues by hydrogen peroxide in petroleum-contaminated soil was investigated at circumneutral pH using a Fenton-like reagent (ferric ion chelated with EDTA). Batch tests were done on 20 g soil suspended in 60 mL aqueous solution containing hydrogen peroxide and Fe{sup 3+}-EDTA complex under constant stirring. A slurry reactor was used to treat the soil based on the optimal reactant conditions. Contaminants were characterized by Fourier transform infrared spectroscopy and Fourier transform ion cyclotron resonance mass spectrometry. The results showed that the optimal treatment condition was: the molar ratio of hydrogen peroxide to iron = 200:1, and pH 7.0. Under the optimum condition, total dichloromethane-extractable organics were reduced from 14,800 to 2300 mg kg{sup -1} soil when the accumulative H{sub 2}O{sub 2} dosage was 2.45 mol kg{sup -1} soil during the reactor treatment. Abundance of viable cells was lower in incubated Fenton-like treated soil than in untreated soil. Oxidation of contaminants produced remarkable compositional and structural modifications. A fused ring compound, identified as C{sub 34}H{sub 38}N{sub 1}, was found to exhibit the greatest resistance to oxidation.

  19. Contamination Control of Freeze Shoe Coring System for Collection of Aquifer Sands

    Science.gov (United States)

    Homola, K.; van Geen, A.; Spivack, A. J.; Grzybowski, B.; Schlottenmier, D.

    2017-12-01

    We have developed and tested an original device, the freeze-shoe coring system, designed to recover undisturbed samples of water contained in sand-dominated aquifers. Aquifer sands are notoriously difficult to collect together with porewater from coincident depths, as high hydraulic permeability leads to water drainage and mixing during retrieval. Two existing corer designs were reconfigured to incorporate the freeze-shoe system; a Hydraulic Piston (HPC) and a Rotary (RC) Corer. Once deployed, liquid CO­2 contained in an interior tank is channeled to coils at the core head where it changes phase, rapidly cooling the deepest portion of the core. The resulting frozen core material impedes water loss during recovery. We conducted contamination tests to examine the integrity of cores retrieved during a March 2017 yard test deployment. Perfluorocarbon tracer (PFC) was added to the drill fluid and recovered cores were subsampled to capture the distribution of PFC throughout the core length and interior. Samples were collected from two HPC and one RC core and analyzed for PFC concentrations. The lowest porewater contamination, around 0.01% invasive fluid, occurs in the center of both HPC cores. The greatest contamination (up to 10%) occurs at the disturbed edges where core material contacts drill fluid. There was lower contamination in the core interior than top, bottom, and edges, as well as significantly lower contamination in HPC cores that those recovered with the RC. These results confirm that the freeze-shoe system, proposed for field test deployments in West Bengal, India, can successfully collect intact porewater and sediment material with minimal if any contamination from drill fluid.

  20. Gas generation from radiolytic attack of TRU-contaminated hydrogenous waste

    International Nuclear Information System (INIS)

    Zerwekh, A.

    1979-06-01

    In 1970, the Waste Management and Transportation Division of the Atomic Energy Commission ordered a segregation of transuranic (TRU)-contaminated solid wastes. Those below a contamination level of 10 nCi/g could still be buried; those above had to be stored retrievably for 20 y. The possibility that alpha-radiolysis of hydrogenous materials might produce toxic, corrosive, and flammable gases in retrievably stored waste prompted an investigation of gas identities and generation rates in the laboratory and field. Typical waste mixtures were synthesized and contaminated for laboratory experiments, and drums of actual TRU-contaminated waste were instrumented for field testing. Several levels of contamination were studied, as well as pressure, temperature, and moisture effects. G (gas) values were determined for various waste matrices, and degradation products were examined

  1. Laser assisted removal of fixed contamination from metallic substrate

    International Nuclear Information System (INIS)

    Kumar, Aniruddha; Prasad, Manisha; Prakash, Tej; Shail, Shailini; Bhatt, R.B.; Behere, P.G.; Mohd Afzal; Kumar, Arun; Biswas, D.J.

    2015-01-01

    A single mode pulsed fiber laser was used to remove fixed contamination from stainless steel substrate by ablation. Samples were simulated by electro-deposition technique with 232 U as the test contaminant. Laser power, repetition rate, laser beam scanning speed and number of passes were optimised to obtain the desired ablation depth in the substrate. Ablation depth varying between few microns to few hundreds of microns could be achieved through careful control of these processing parameters. The absence of any activity in laser treated samples provided experimental signature of the efficacy of the laser assisted removal of fixed contamination. (author)

  2. Assessment of the consequences of the radioactive contamination of aquatic media and biota. Model testing using Chernobyl data

    International Nuclear Information System (INIS)

    Kryshev, I.; Sazykina, T.; Hoffman, O.; Thiessen, K.

    1996-09-01

    The 'Cooling Pond' scenario was designed to test models for radioactive contamination of aquatic ecosystems, based on data for contamination of different aquatic media and biota due to fallout of radionuclides into the cooling pond of the Chernobyl Nuclear Power Plant. Input data included characteristics of the cooling pond ecosystem (hydrological, hydrochemical, and hydro biological conditions) and estimates of the amounts of 137 Cs in the cooling pond. Predictions were requested in two stages: (1) Calculations of 137 Cs concentrations for comparison against actual measurements, including activities of 137 Cs in the cooling pond water, in layers of sediment, and in fish; (2) Calculations for which actual measurements are not available, including dose and risk estimates for aquatic biota and for humans following hypothetical consumption of contaminated biota. Calculations were performed with the following models: LAKECO (Netherlands), POSOD (USA), LAKEPOND (Romania), WATER (Russia), GIDRO (Russia), and ECOMOD-W (Russia). The total number of scenario calculations was 18. In general, the models tended to overestimate the total doses to fish (as compared to to independent dose estimates made from measured concentrations by the scenario authors) for internal and external exposure, while a number of predictions with different models for the effective dose and risk to humans from fish consumption were in good agreement with independent test estimates. The differences among model predictions were somewhat smaller for the total doses to fish than for the environmental concentrations used in the model testing. The differences among model predictions were very great for the effective doses and risk to humans from fish consumption. This is related to distinct errors in assessments of 137 Cs concentrations in fish. Very few participants obtained good agreement with respect to all criteria of the model testing, i.e., 137 Cs concentrations in the aquatic ecosystem components and

  3. Assessment of the consequences of the radioactive contamination of aquatic media and biota. Model testing using Chernobyl data

    Energy Technology Data Exchange (ETDEWEB)

    Kryshev, I.; Sazykina, T. [SPA Typhoon, Obninsk (Russian Federation); Hoffman, O.; Thiessen, K. [SENES, Oak Ridge, TN (United States)] [and others

    1996-09-01

    The 'Cooling Pond' scenario was designed to test models for radioactive contamination of aquatic ecosystems, based on data for contamination of different aquatic media and biota due to fallout of radionuclides into the cooling pond of the Chernobyl Nuclear Power Plant. Input data included characteristics of the cooling pond ecosystem (hydrological, hydrochemical, and hydro biological conditions) and estimates of the amounts of 137 Cs in the cooling pond. Predictions were requested in two stages: (1) Calculations of 137 Cs concentrations for comparison against actual measurements, including activities of 137 Cs in the cooling pond water, in layers of sediment, and in fish; (2) Calculations for which actual measurements are not available, including dose and risk estimates for aquatic biota and for humans following hypothetical consumption of contaminated biota. Calculations were performed with the following models: LAKECO (Netherlands), POSOD (USA), LAKEPOND (Romania), WATER (Russia), GIDRO (Russia), and ECOMOD-W (Russia). The total number of scenario calculations was 18. In general, the models tended to overestimate the total doses to fish (as compared to to independent dose estimates made from measured concentrations by the scenario authors) for internal and external exposure, while a number of predictions with different models for the effective dose and risk to humans from fish consumption were in good agreement with independent test estimates. The differences among model predictions were somewhat smaller for the total doses to fish than for the environmental concentrations used in the model testing. The differences among model predictions were very great for the effective doses and risk to humans from fish consumption. This is related to distinct errors in assessments of 137 Cs concentrations in fish. Very few participants obtained good agreement with respect to all criteria of the model testing, i.e., 137 Cs concentrations in the aquatic ecosystem

  4. Corrective Action Investigation Plan for Corrective Action Unit 166: Storage Yards and Contaminated Materials, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    David Strand

    2006-01-01

    Corrective Action Unit 166 is located in Areas 2, 3, 5, and 18 of the Nevada Test Site, which is 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit (CAU) 166 is comprised of the seven Corrective Action Sites (CASs) listed below: (1) 02-42-01, Cond. Release Storage Yd - North; (2) 02-42-02, Cond. Release Storage Yd - South; (3) 02-99-10, D-38 Storage Area; (4) 03-42-01, Conditional Release Storage Yard; (5) 05-19-02, Contaminated Soil and Drum; (6) 18-01-01, Aboveground Storage Tank; and (7) 18-99-03, Wax Piles/Oil Stain. These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation (CAI) before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on February 28, 2006, by representatives of the Nevada Division of Environmental Protection; U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and Bechtel Nevada. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 166. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to each CAS. The scope of the CAI for CAU 166 includes the following activities: (1) Move surface debris and/or materials, as needed, to facilitate sampling. (2) Conduct radiological surveys. (3) Perform field screening. (4) Collect and submit environmental samples for laboratory analysis to determine if

  5. Contamination and decontamination of vehicles when driven in radioactive areas

    International Nuclear Information System (INIS)

    Ulvsand, T.; Nygren, U.

    1999-10-01

    There is reason to ask whether it is beneficial to decontaminate vehicles, in view of the great effort applied. If the level of contamination is low before the decontamination process, then the cost is not motivated, even if the decontamination is shown to be effective in relative terms. The report describes two trials at the National NBC Defence School in Umeaa and one trial at the French test site in Bourges. The aim is to investigate how vehicles are contaminated and at which ground deposition levels troublesome levels of contamination will arise. In the trials, a non-radioactive agent substituting real radioactivity was used. The trials in Sweden so far have used the oversnow vehicle BV 206, during both winter and summer conditions. The vehicles were driven a specific distance along a road on which a known amount of the test substance had been dispersed. Samples were taken on pre-determined areas on one side of the vehicles to measure the amount of test substance. Later, the vehicles continued along a 'clean' road where additional samples were taken, but on the other side of the vehicles. The largest amount of test substance was collected on the tracks and on the back of the vehicle. The tracks and mud-flaps were effectively decontaminated when the vehicles were driven along a clean road, while most of the contamination remained on the backside. The purpose of the trials in France was to compare the results from our non-radioactive and their radioactive method, based on the radioactive La-140. Due to ground conditions, the level of contamination on the vehicles was much less than in the trials in Umeaa, but the effect decontamination could be measured after all

  6. Experimental study on source efficiencies for estimating surface contamination level

    International Nuclear Information System (INIS)

    Ichiji, Takeshi; Ogino, Haruyuki

    2008-01-01

    Source efficiency was measured experimentally for various materials, such as metals, nonmetals, flooring materials, sheet materials and other materials, contaminated by alpha and beta emitter radioactive nuclides. Five nuclides, 147 Pm, 60 Co, 137 Cs, 204 Tl and 90 Sr- 90 Y, were used as the beta emitters, and one nuclide 241 Am was used as the alpha emitter. The test samples were prepared by placing drops of the radioactive standardized solutions uniformly on the various materials using an automatic quantitative dispenser system from Musashi Engineering, Inc. After placing drops of the radioactive standardized solutions, the test materials were allowed to dry for more than 12 hours in a draft chamber with a hood. The radioactivity of each test material was about 30 Bq. Beta rays or alpha rays from the test materials were measured with a 2-pi gas flow proportional counter from Aloka Co., Ltd. The source efficiencies of the metals, nonmetals and sheet materials were higher than 0.5 in the case of contamination by the 137 Cs, 204 Tl and 90 Sr- 90 Y radioactive standardized solutions, higher than 0.4 in the case of contamination by the 60 Co radioactive standardized solution, and higher than 0.25 in the case of contamination by the alpha emitter the 241 Am radioactive standardized solution. These values were higher than those given in Japanese Industrial Standards (JIS) documents. In contrast, the source efficiencies of some permeable materials were lower than those given in JIS documents, because source efficiency varies depending on whether the materials or radioactive sources are wet or dry. This study provides basic data on source efficiency, which is useful for estimating the surface contamination level of materials. (author)

  7. Decontamination technology of contaminated water with flocculating and settling technology

    International Nuclear Information System (INIS)

    Aritomi, Masanori; Adachi, Toshihiro; Watanabe, Noriyuki; Hosobuchi, Shigeki

    2012-01-01

    In the joint research and development of treatment systems of cooling water for cutting asphalt pavement surface with our authors' group, the liquid-solid separation technology by flocculating and settling technology, and the flocculants for the use of systems were developed. In this paper, the developed flocculating and settling technology and the flocculants are discussed first. Next, the demonstration tests of decontamination technology on the contaminated water in swimming pools in an elementary school located at Motomiya City, Fukushima Prefecture had been conducted by use of the stationary purification system of contaminated water and the flocculants compounding with or without iron ferrocianide developed by the preliminary test. It was clarified from the results that ionized cesium (Cs) rarely exists in the stagnant water in pools, ponds, lakes and so on at the time when nine months have passed since Fukushima Dai-ichi nuclear power plant accidents. Further, it is necessary to use the flocculants compounding iron ferrocianide in the case where ionized Cs exists in water. From the above-mentioned results, the following problems were pointed out: One problem was cyanide dissolution in the purified water and the other one was the dissolution from the dehydration sludge. Finally, the high-performance mobile purification units of contaminated water which is capable for carrying with trucks have been developed, and the demonstration test was performed in Minami-soma City, Fukushima Prefecture to purify the contaminated water in a pond and generated by the high-pressure water washing in a Public Hall. From the test results, it was made clear that the dehydration sludge separated by liquid-solid settling of the contaminated water of around 1,000Bq/l became a high radiation dose of about 185,000Bq/l. (author)

  8. Radioactive contamination of protective clothes made of textile and their decontamination in aqueous solutions

    International Nuclear Information System (INIS)

    Fukumori, D.T.

    1989-01-01

    This dissertation deals with the radioactive contamination, its prevention, control and decontamination, related to protective clothing made of textile and usually weared in normal working conditions, within the installations where radioactive materials are handled or processed, especially as unsealed sources. The features of textile materials and contaminants, contamination mechanisms, risks related to contaminated clothes, planning of working areas, monitoring and surface contamination limits are described. Concerning to decontamination, the reagents, their action mechanisms and methods of efficiency evaluation are emphasized. The selected reagents were experimentally tested and their efficiencies in decontaminating cotton cloth samples, contaminated with uranyl nitrate solution, were evaluated by means of counting rate determined with a Geiger-Muller provided counting system. In this way, complexing agents, surfactants and commercial cleanning products were tested. The results were analysed and interpreted considering statistical, radiochemical and Radiation Protection aspects. Both, the radiactive contamination and decontamination of protective clothes are extensive matters and they still could be developed and improved; thus, many suggestions were presented as further studies. (author) [pt

  9. Ecotoxicological hazard assessment of hydrocarbon contaminated soils: A case study

    International Nuclear Information System (INIS)

    Roy, Y.; Pauwels, S.J.; Chasse, R.

    1994-01-01

    The Ecotoxicological Hazard Assessment (EHA) developed by the Quebec Ministry of Environment and Wildlife was used as part of the management scheme of contaminated soils from a former refinery. The study consists of assessing five types of soils (reference, heavily contaminated, slightly contaminated, thermally-treated, and biotreated) to determine their relative intrinsic hazard. During the exploratory activities a series of ten assessment endpoints where identified to support this typical EHA. During SOURCE characterization, the physicochemical make-up of the soils is described and the presence and concentrations of priority pollutants is determined. During FATE characterization, the potential for bioconcentration, mobility, and persistence of pollutants is determined. During EFFECTS characterization, the soils and their leachates are tested using standard terrestrial and aquatic bioassays. The data from the toxicological and analytical testing program are evaluated semi-quantitatively on the basis of a scoring system developed by consensus. The discussion will highlight how data are used within an EHA to streamline the decision-making process regarding the follow-up cleanup and disposal of contaminated soils

  10. SURROGATE SPECIES IN ASSESSING CONTAMINANT RISK FOR ENDANGERED FISHES

    Science.gov (United States)

    Rainbow trout, fathead minnows, and sheepshead minnows were tested as surrogate species to assess contaminant risk for 17 endangered fishes and one toad species. Acute toxicity tests were conducted with carbaryl, copper, 4-nonylphenol, pentachlorophenol, and permethrin in accord...

  11. Assessment of Microbial Contamination of Traditional Sweets in Yazd, Iran, in 2015

    Directory of Open Access Journals (Sweden)

    hamidreza nasehinia

    2017-03-01

    samples were tested in terms of such microorganisms as Enterobacteriaceae, Escherichia coli, yeasts, and molds, using the microbiological tests, which were based on the Iranian national standards.Results: According to the results, the prevalence rate of microbial contaminations was 33.8% (n=322. Furthermore, the “Pistachio Luz” and “Hajji Badam” had the highest (88.8% and lowest (0% prevalence rates of  microbial contamination, respectively. Additionally, the prevalence rate of contamination to Enterobacteriaceae, Escherichia coli, Molds, and Yeasts were 13.2%, 5%, 21.7%, and 11.4%, respectively. Conclusion: Given the high rate of microbial contamination in the traditional sweets, especially “Pistachio Luz”, offered in Yazd, more regulatory and monitoring measures should be taken in the production and distribution of these sweets. 

  12. The influence of Ferric ion contamination on the solid polymer electrolyte water electrolysis performance

    International Nuclear Information System (INIS)

    Wang, Xunying; Zhang, Linsong; Li, Guangfu; Zhang, Geng; Shao, Zhi-Gang; Yi, Baolian

    2015-01-01

    Highlights: • The cathode possesses higher tolerance for the Fe 3+ contamination than the anode. • Fe 3+ are mostly reduced to Fe 2+ rather than occur underpotential deposition. • Increased electrolysis voltage was mainly attributed to ohmic overpotential. • Voltage lags behind current for minutes in the multi-current-step test. • Poisoned electrolyser is mostly recovered by 0.5 M H 2 SO 4 solution treatment for 13 h. - Abstract: Fe 3+ is a sort of common metal ion contaminant for the solid polymer electrolyte (SPE) water electrolyser. In this paper, the effect of Fe 3+ on the performance of SPE water electrolyser has been investigated by both in-situ and ex-situ characterizations. The electron probe microanalysis and ultraviolet test results showed that Fe 3+ could migrate from the anode to the cathode and mostly be reduced to Fe 2+ in the cathode rather than occurred underpotential deposition as described in the previous report. The in-situ dynamic contamination test showed that the anode voltage increased sharply as soon as the Fe 3+ was fed into the anode, while the cathode voltage kept constant until the contamination time was over 30 minutes, indicating the higher tolerance of the cathode than the anode for the Fe 3+ contamination. The calculation results based on the electrochemistry impedance spectroscopy test results revealed that the striking increase of the electrolysis voltage was mainly attributed to the ohmic overpotential, which was due to the replacement of H + by Fe 3+ in the Nafion resin. Interestingly, the voltage lagged behind the current for several minutes in the multi-current-step test for the contaminated electrolyser, which phenomenon may be used for judging whether the SPE water electrolyser performance degradation is due to the metal ions contamination. Furthermore, recovery strategy has been developed, and it was found that the contaminated electrolyser could be mostly recovered by 0.5 M H 2 SO 4 solution treatment for 13 h

  13. Trace Contaminant Control During the International Space Station's On-Orbit Assembly and Outfitting

    Science.gov (United States)

    Perry, J. L.

    2017-01-01

    Achieving acceptable cabin air quality must balance competing elements during spacecraft design, assembly, ground processing, and flight operations. Among the elements that contribute to the trace chemical contaminant load and, therefore, the cabin air quality aboard crewed spacecraft are the vehicle configuration, crew size and activities, mission duration and objectives, materials selection, and vehicle manufacturing and preflight ground processing methods. Trace chemical contaminants produced from pervasive sources such as equipment offgassing, human metabolism, and cleaning fluids during preflight ground processing present challenges to maintaining acceptable cabin air quality. To address these challenges, both passive and active contamination control techniques are used during a spacecraft's design, manufacturing, preflight preparation, and operational phases. Passive contamination control methods seek to minimize the equipment offgassing load by selecting materials, manufacturing processes, preflight preparation processes, and in-flight operations that have low chemical offgassing characteristics. Passive methods can be employed across the spacecraft's entire life cycle from conceptual design through flight operations. However, because the passive contamination control techniques cannot fully eliminate the contaminant load, active contamination control equipment must be deployed aboard the spacecraft to purify and revitalize the cabin atmosphere during in-flight operations. Verifying that the passive contamination control techniques have successfully maintained the total trace contaminant load within the active contamination control equipment's capabilities occurs late in the preflight preparation stages. This verification consists of subjecting the spacecraft to an offgassing test to determine the trace contaminant load. This load is then assessed versus the active contamination control equipment's capabilities via trace contaminant control (TCC) engineering

  14. Bacterial Contamination of Hands Increases Risk of Cross-Contamination among Low-Income Puerto Rican Meal Preparers

    Science.gov (United States)

    Dharod, Jigna Morarji; Paciello, Stefania; Bermudez-Millan, Angela; Venkitanarayanan, Kumar; Damio, Grace; Perez-Escamilla, Rafael

    2009-01-01

    Objective: To examine the association of microbial contamination of the meal preparer's hands with microbial status of food and kitchen/utensil surfaces during home preparation of a "Chicken and Salad" meal. Design and Setting: Observational home food safety assessment. Before starting meal preparation, participants' hands were tested to…

  15. Disgust and contamination sensitivity in vaginismus and dyspareunia.

    Science.gov (United States)

    de Jong, Peter J; van Overveld, Mark; Schultz, Willibrord Weijmar; Peters, Madelon L; Buwalda, Femke M

    2009-04-01

    This study examined the potential role of disgust propensity and contamination sensitivity in vaginismus. Women suffering from vaginismus (n = 20) or dyspareunia (n = 22), and a group of women without sexual complaints (n = 30) completed self report measures indexing their (1) general dispositional disgust propensity, and (2) sensitivity for (ideational) contamination by sexual stimuli as a function of its source (self, partner, unknown). In support of the idea that disgust may be involved in vaginismus, women with vaginistic complaints displayed a generally enhanced dispositional disgust propensity. The sensitivity for contamination by sexual stimuli did not vary across groups. However, especially when the source was the participant's partner, the willingness ratings might have been influenced by demand and may, therefore, not accurately reflect participant's actual sensitivity for contamination by sexual stimuli. Future studies using more implicit or behavioral measures are necessary to more definitely test the role of disgust in vaginismus.

  16. Selective flotation for the removal of radionuclides from contaminated soil

    International Nuclear Information System (INIS)

    Miller, J.D.; Yu, Q.; Lu, Y.Q.

    1995-01-01

    Low-level radioactive contaminated soils (10--500 pci/gm) created by defense-related activities at certain Superfund sites, such as Nevada Test Site (NTS), is a current environmental concern. Many of these contaminated sites may require appropriate cleanup and restoration, which could cost billions of dollars and put tremendous pressure on limited financial resources. Therefore, the development of a selective flotation process to separate such radionuclides from contaminated soils should be considered. In this study, both a pure depleted UO 2 sample and three synthetic UO 2 /soil mixtures were used to evaluate surface chemistry features and to examine the possibility for the flotation of fine UO 2 particles from selected soils. It was intended that this model system would be a reasonable representation of contaminated soils such as those found the Nevada Test Site which are reported to be contaminated by PuO 2 fallout. The effect of reagent schedule, particle size distribution, and surface charge are discussed with respect to the flotation separation of the UO 2 /soil mixtures. It was found that both commercial fatty acids and reagent grade sodium oleate are effective collectors for UO 2 flotation provided the pH is adjusted to the range of pH 8--9. The bench-scale flotation results successfully demonstrated that froth flotation technology can be used to remove UO 2 from such model contaminated soils with appropriate flotation chemistry conditions which depend on the soil characteristics and other pretreatment procedures

  17. Assessment of radioactive contaminations of the ground in Hanover-List with scales and methods of the German Federal Ordinance on Soil Protection and Contaminated Sites (BBodSchV). Pt. 2. Application of test thresholds and determination of need for actions

    International Nuclear Information System (INIS)

    Gellermann, Rainer; Guenther, Petra; Evers, Burkhard

    2010-01-01

    In Part 1 of this paper test thresholds for radionuclides in soil have been derived on the basis of methods and scales of the German Ordinance on Soil Protection (BBodSchV). In this paper, these test thresholds are checked with regard to their plausibility. Materials, methods, results are described in Part 1 of this paper. This contribution demonstrates that the test thresholds derived in Part 1 are plausible and feasible according to the requirements of the established methods. The epidemiological basis for the treatment of ionizing radiation is well founded. Risks can be quantified via the knowledge of cancer risks due to radiation. As a reference value the overall fatal risk coefficient of 5 % per Sv recommended by ICRP is used. The test thresholds obtained are sufficiently far from background levels in soils of northern Germany. Consequently, the test thresholds are applicable without any background corrections. Exposures by external radiation outdoors and exposures by inhalation of radon in cellar rooms result in calculated test thresholds in the order of background levels. Nevertheless, feasible results are obtained because in the case of toxic substances without threshold levels the additional exposures are considered for determination of test thresholds. The approach of test thresholds for radioactive soil contamination presented in Part 1 of this paper complies with the criteria of the German methods for calculation of test thresholds in soil protection regarding plausibility and feasibility. It enables the soil protection authorities to assess radioactive contaminations of the ground according to the established rules in the field of soil protection and to make decisions according to Articles 9 and 10 of the German Soil Protection Act. Part 3 of this paper discusses the application of the test thresholds and the possibilities of determining the need for remediation actions. (orig.)

  18. Approximating dose and risk for contaminants in groundwater from the underground nuclear test areas of the Nevada National Security Site (NNSS)

    Energy Technology Data Exchange (ETDEWEB)

    Daniels, Jeffrey I. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Chapman, Jenny [Desert Research Inst. (DRI), Las Vegas, NV (United States); Pohlmann, Karl F. [Desert Research Inst. (DRI), Las Vegas, NV (United States)

    2015-03-01

    As part of the Environmental Management Program at the Nevada National Security Site (NNSS), the Underground Test Area (UGTA) Activity investigates the potential impacts of radionuclides that were introduced into groundwater from the underground nuclear tests conducted near or below the NNSS water table between 1951 and 1992. Groundwater models are being used to simulate contaminant transport and forecast contaminant boundaries that encompass areas where the groundwater has a five percent or greater probability of containing contaminants above the Safe Drinking Water Act Maximum Contaminant Levels (SDWA MCLs) at any time during the next 1,000 years. Transport modeling conducted for the Frenchman Flat Corrective Action Unit (CAU) at the NNSS identified the beta/photon-emitting radionuclides tritium (3H), carbon-14 (14C), chlorine-36 (36Cl), technetium-99 (99Tc), and iodine-129 (129I) as having the greatest influence in defining the farthest extent of the modeled CAU contaminant boundary. These same radionuclides are assumed here as the contaminants of concern (COCs) for all underground nuclear tests at the NNSS because models are not yet complete for the other CAUs.Potential public exposure to the COCs will only occur and be of concern if the COCs migrate into the groundwater beneath public or private lands at levels that exceed either individual SDWA MCLs or dose and risk limits. Groundwater flow directions strongly suggest that any contaminant boundary predicted by contaminant fate and transport modeling to overlap public or private lands is more likely to occur to the west and/or southwest of the NNSS and the adjacent Nevada Test and Training Range (NTTR). Well-established, rural communities exist in these directions. Estimates of representative activity concentrations at the applicable SDWA MCL were developed for the five COCs. It is assumed that these COC concentrations may collectively occur at some public or private location in the future, but that situation

  19. (CultiAF) Reducing maize-based aflatoxin contamination

    International Development Research Centre (IDRC) Digital Library (Canada)

    In Zimbabwe, testing of harvested maize has revealed high levels of contamination by aflatoxins, ... and other private sector partners will increase the availability of improved grain storage containers. Researchers will work with the Ministry of ...

  20. Joint use of laboratory bioassays and field-collected invertebrates to evaluate toxicity and contaminant bioaccumulation

    International Nuclear Information System (INIS)

    Long, S.P.; Byron, E.R.; Ohlendorf, H.M.

    1995-01-01

    Soil toxicity tests using earthworms (Eisenia andrei) were conducted using soil samples collected as part of ecological risk assessments for several sites at two facilities in California. At some sites, earthworms or other terrestrial invertebrates were collected in the field for chemical analysis. Ecological concerns focused on exposures to soil invertebrates and their secondary consumers, such as birds and small mammals. The toxicity tests were used to assess potential exposures to a variety of site-specific contaminants including organochlorine pesticides, PCBs, PAHs, petroleum hydrocarbons, heavy metals, and other inorganic substances. Site soils were combined with clean control soils to produce toxicity test soil dilutions containing 100%, 75%, 50%, 25%, and 0% site soils. Earthworm mortality and other observations were made at day 0, 7, 14, 21 and 28. Toxicity test results were combined with soil chemical analytical results and physical characteristics to establish NOAELs and LOAELs. Bioaccumulation in the laboratory earthworms and field-collected invertebrates was evaluated by comparing whole-body contaminant to soil contaminant concentrations. Allometric equations and sublethal toxicity data were used to predict potential effects on birds and small mammals. Earthworm toxicity tests indicated a wide range of sensitivity to on-site contaminants and showed the importance of considering potential confounding influences due to soil parameters other than contaminant concentration

  1. RI Mapping System for Identification of Radiological Contamination in Environmental Water Supply System

    Energy Technology Data Exchange (ETDEWEB)

    Na, Teresa W.; Ha, Jang Ho; Kim, Han Soo; Lee, Seung Hyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Na, Teresa W.; Lee, Rena [Ewha Womans Univ., Hospital, Seoul (Korea, Republic of)

    2012-03-15

    The interest of radiation protection has risen due to accidents of the Nuclear Power Plant, nuclear terrorism, and the radiological contamination in the city, In this respect, the development of environmental radiation monitoring for the radiological contaminants has been studied. In this study, the experiment for the radiological contamination in the water supply pipe line system has been simulated and preliminarily tested. The CsI(Tl)-PIN diode detectors were used and the preliminary test of radiation monitoring system was performed as multi detection system. The 2D image reconstruction algorithm was also developed for feasibility of the constructed multi-detection system.

  2. Bioremediation of petroleum-contaminated soil

    International Nuclear Information System (INIS)

    Pearce, K.; Snyman, H.G.; Oellermann, R.A.; Gerber, A.

    1995-01-01

    A pilot-scale study was conducted to evaluate the application of land-farming techniques in bioremediating a soil highly contaminated with petroleum products. A commercial biosupplement, and one prepared with indigenous microorganisms from the contaminated soil, were tested. Application of either of the biosupplements, in addition to the control of pH, moisture, and oxygen levels, resulted in a 94% reduction of the initial total petroleum hydrocarbon concentration (TPHC) (32% mass/mass) over a 70-day period. Implementation of these findings at full scale to bioremediate highly weathered petroleum products showed an average reduction of 89% over 5.5 months. Target levels of 1,400 mg/kg soil were reached from an initial average TPHC concentration of 12,200 mg/kg soil

  3. Contamination-free sounding rocket Langmuir probe

    Science.gov (United States)

    Amatucci, W. E.; Schuck, P. W.; Walker, D. N.; Kintner, P. M.; Powell, S.; Holback, B.; Leonhardt, D.

    2001-04-01

    A technique for removing surface contaminants from a sounding rocket spherical Langmuir probe is presented. Contamination layers present on probe surfaces can skew the collected data, resulting in the incorrect determination of plasma parameters. Despite following the usual probe cleaning techniques that are used prior to a launch, the probe surface can become coated with layers of adsorbed neutral gas in less than a second when exposed to atmosphere. The laboratory tests reported here show that by heating the probe from the interior using a small halogen lamp, adsorbed neutral particles can be removed from the probe surface, allowing accurate plasma parameter measurements to be made.

  4. Plant Mounds as Concentration and Stabilization Agents for Actinide Soil Contaminants in Nevada

    Energy Technology Data Exchange (ETDEWEB)

    D.S. Shafer; J. Gommes

    2009-02-03

    Plant mounds or blow-sand mounds are accumulations of soil particles and plant debris around the base of shrubs and are common features in deserts in the southwestern United States. An important factor in their formation is that shrubs create surface roughness that causes wind-suspended particles to be deposited and resist further suspension. Shrub mounds occur in some plant communities on the Nevada Test Site, the Nevada Test and Training Range (NTTR), and Tonopah Test Range (TTR), including areas of surface soil contamination from past nuclear testing. In the 1970s as part of early studies to understand properties of actinides in the environment, the Nevada Applied Ecology Group (NAEG) examined the accumulation of isotopes of Pu, 241Am, and U in plant mounds at safety experiment and storage-transportation test sites of nuclear devices. Although aerial concentrations of these contaminants were highest in the intershrub or desert pavement areas, the concentration in mounds were higher than in equal volumes of intershrub or desert pavement soil. The NAEG studies found the ratio of contaminant concentration of actinides in soil to be greater (1.6 to 2.0) in shrub mounds than in the surrounding areas of desert pavement. At Project 57 on the NTTR, 17 percent of the area was covered in mounds while at Clean Slate III on the TTR, 32 percent of the area was covered in mounds. If equivalent volumes of contaminated soil were compared between mounds and desert pavement areas at these sites, then the former might contain as much as 34 and 62 percent of the contaminant inventory, respectively. Not accounting for radionuclides associated with shrub mounds would cause the inventory of contaminants and potential exposure to be underestimated. In addition, preservation of shrub mounds could be important part of long-term stewardship if these sites are closed by fencing and posting with administrative controls.

  5. A latex agglutination test for the field determination of abnormal vitellogenin production in male fishes contaminated by estrogen mimics

    International Nuclear Information System (INIS)

    Magalhaes, Ilizabete; Pihan, Jean-Claude; Falla, Jairo

    2004-01-01

    Estrogen mimics are pollutants present in the aquatic environment. These compounds induce abnormalities in the reproductive system of male fishes, which lead to a total or partial male feminization, or to their demasculinization. Ultimately, these alterations could lead to a disappearance of the total contaminated fish population. Moreover, these toxic substances possess the capacity to mimic endogenous estrogens and to induce the abnormal production of vitellogenin (VTG) in male and immature fishes. The purpose of this research was to develop an easy, specific, cheap and fast method for diagnosing the contamination of male fishes by estrogen mimics, using VTG as biomarker. The selected method is based on a reverse latex agglutination test (rLAT), developed with monoclonal antibodies specific of this biomarker. The development of this VTG-rLAT has involved, firstly, the purification of carp VTG to produce monoclonal antibodies, specifics of this protein. One of these antibodies was selected to recover latex particles (diameter: 1 μm). Finally, the immunoreactivity of the VTG-rLAT was verified with different fish plasma samples from males treated with 17β-estradiol and non-treated males or females in vitellogenesis

  6. Recovery of Mercury From Contaminated Liquid Wastes

    International Nuclear Information System (INIS)

    1998-01-01

    The Base Contract program emphasized the manufacture and testing of superior sorbents for mercury removal, testing of the sorption process at a DOE site, and determination of the regeneration conditions in the laboratory. During this project, ADA Technologies, Inc. demonstrated the following key elements of a successful regenerable mercury sorption process: (1) sorbents that have a high capacity for dissolved, ionic mercury; (2) removal of ionic mercury at greater than 99% efficiency; and (3) thermal regeneration of the spent sorbent. ADA's process is based on the highly efficient and selective sorption of mercury by noble metals. Contaminated liquid flows through two packed columns that contain microporous sorbent particles on which a noble metal has been finely dispersed. A third column is held in reserve. When the sorbent is loaded with mercury to the point of breakthrough at the outlet of the second column, the first column is taken off-line and the flow of contaminated liquid is switched to the second and third columns. The spent column is regenerated by heating. A small flow of purge gas carries the desorbed mercury to a capture unit where the liquid mercury is recovered. Laboratory-scale tests with mercuric chloride solutions demonstrated the sorbents' ability to remove mercury from contaminated wastewater. Isotherms on surrogate wastes from DOE's Y-12 Plant in Oak Ridge, Tennessee showed greater than 99.9% mercury removal. Laboratory- and pilot-scale tests on actual Y-12 Plant wastes were also successful. Mercury concentrations were reduced to less than 1 ppt from a starting concentration of 1,000 ppt. The treatment objective was 50 ppt. The sorption unit showed 10 ppt discharge after six months. Laboratory-scale tests demonstrated the feasibility of sorbent regeneration. Results show that sorption behavior is not affected after four cycles

  7. Field tests of a chemiresistor sensor for in-situ monitoring of vapor-phase contaminants

    Science.gov (United States)

    Ho, C.; McGrath, L.; Wright, J.

    2003-04-01

    An in-situ chemiresistor sensor has been developed that can detect volatile organic compounds in subsurface environmental applications. Several field tests were conducted in 2001 and 2002 to test the reliability, operation, and performance of the in-situ chemiresistor sensor system. The chemiresistor consists of a carbon-loaded polymer deposited onto a microfabricated circuit. The polymer swells reversibly in the presence of volatile organic compounds as vapor-phase molecules absorb into the polymer, causing a change in the electrical resistance of the circuit. The change in resistance can be calibrated to known concentrations of analytes, and arrays of chemiresistors can be used on a single chip to aid in discrimination. A waterproof housing was constructed to allow the chemiresistor to be used in a variety of media including air, soil, and water. The integrated unit, which can be buried in soils or emplaced in wells, is connected via cable to a surface-based solar-powered data logger. A cell-phone modem is used to automatically download the data from the data logger on a periodic basis. The field tests were performed at three locations: (1) Edwards Air Force Base, CA; (2) Nevada Test Site; and (3) Sandia's Chemical Waste Landfill near Albuquerque, NM. The objectives of the tests were to evaluate the ruggedness, longevity, operation, performance, and engineering requirements of these sensors in actual field settings. Results showed that the sensors could be operated continuously for long periods of time (greater than a year) using remote solar-powered data-logging stations with wireless telemetry. The sensor housing, which was constructed of 304 stainless steel, showed some signs of corrosion when placed in contaminated water for several months, but the overall integrity was maintained. The detection limits of the chemiresistors were generally found to be near 0.1% of the saturated vapor pressure of the target analyte in controlled laboratory conditions (e

  8. Biological detoxification of a hydrocarbon contaminated soil

    International Nuclear Information System (INIS)

    Fabbri, F.; Lucchese, G.; Nardella, A.

    2005-01-01

    The soil quality of an industrial site chronically contaminated by 39000 mg/kg of oil was detrimentally affected. Soil treatments by bio-pile and land-farming resulted in a reduction of the level of contamination exceeding 90% of the original values, but without reaching regulatory limits. However, the bio-remediation treatments dramatically reduced the mobility of the contaminants and, accordingly, microbial tests clearly indicate that the soil quality improved to acceptable levels, similar to those typically observed in unaltered soils. Hydrocarbon mobility was estimated by the use of water and mild extractants (methanol and sodium dodecyl sulphate) to leach the contaminants from the soil; soil quality was evaluated by comparing the values of selected microbial and enzymatic parameters of the treated soil samples to reference values determined for natural soils. Microbial assessments included: measurement of the nitrification potential, dehydrogenase activity, measures of respiration and lipase activity, microbial counts (MPN on rich media) and Microtox TM assays of the water elutriate. Dermal absorption potential was evaluated using absorption on C 18 disks

  9. Treatment of chromium contaminated soil using bioremediation

    Science.gov (United States)

    Purwanti, Ipung Fitri; Putri, Tesya Paramita; Kurniawan, Setyo Budi

    2017-11-01

    Chromium contamination in soil occurs due to the disposal of chromium industrial wastewater or sludge that excess the quality standard. Chromium concentration in soil is ranged between 1 to 300 mg/kg while the maximum health standard is 2.5 mg/kg. Bioremediation is one of technology that could be used for remediating heavy metal contamination in soil. Bacteria have an ability to remove heavy metal from soil. One bacteria species that capable to remove chromium from soil is Bacillus subtilis. The aim of this research was to know the chromium removal percentage in contaminated soil by Bacillus subtilis. Artificial chromium contaminated soil was used by mixing 425gram sand and chromium trichloride solution. Concentration of chromium added into the spiked soil were 50, 75, and 100 mg/L. During 14 days, pH, soil temperature and soil moisture were tested. Initial and final number of bacterial colony and chromium concentration analysed. The result showed that the highest percentage of chromium removal was 11% at a chromium concentration of 75 mg/L

  10. Climatic Reliability of Electronics: Early Prediction and Control of Contamination and humidity effects

    DEFF Research Database (Denmark)

    Verdingovas, Vadimas

    were to a significant extent guided by the climatic reliability issues the electronic companies are currently facing. The research in this thesis is focused on the synergistic effects of process related contamination, humidity, potential bias, and PCBA design related aspects, while various tests...... assuming parasitic circuit due to water layer formation on the PCBA surface. The chapters 2-5 review the factors influencing the climatic reliability of electronics namely humidity interaction with materials and ionic contamination on the PCBA surface, common types and sources of ionic contamination...... in electronics, the test methods and techniques, and failure mechanisms related to climate and contamination. Chapter 6 summarizes the materials and experimental methods employed in this thesis. The results of various investigations are presented as individual research papers as published or in the draft form...

  11. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF THREE IMMUNOASSAY TEST KITS FOR ANTHRAX, BOTULINUM TOXIN AND RICIN

    Science.gov (United States)

    Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....

  12. Ten years' experience in determining internal contamination among plutonium laboratory workers

    International Nuclear Information System (INIS)

    Deworm, J.; Fieuw, G.

    1976-01-01

    Glove boxes in plutonium laboratories are fitted with ''sniffers'' (air samplers), which evaluate atmospheric contamination. The results of the measurements over a ten-year period of operation are available, and cases of detection in this way of air contamination exceeding the maximum permissible concentrations are exceptional. During contamination aerodynamic particle diameters of 1 - 4 μm were measured. The concentration and characteristics of the aerosol have made it possible to ascertain the inhalable fraction and to estimate the pulmonary and systemic burden in workers. The workers exposed in the laboratories undergo a urine test each month. The results obtained show that there is little risk of internal contamination without the person concerned being aware of an abnormal situation. In the majority of cases it is possible to take proper precautions and to collect the data necessary for evaluating the body burden. Three cases of specific contamination are examined in detail: contamination by plutonium and americium from a non-identified source, detected by routine urine analysis; contamination by inhalation of plutonium; an injury to the left forefinger, accompanied by plutonium contamination. (author)

  13. Stabilization of contaminated soils by in situ vitrification

    International Nuclear Information System (INIS)

    Timmerman, C.L.

    1984-01-01

    In Situ Vitrification is an emerging technology developed by Pacific Northwest Laboratory for potential in-place immobilization of radioactive wastes. The contaminated soil is stabilized and converted to an inert glass form. This conversion is accomplished by inserting electrodes in the soil and establishing an electric current between the electrodes. The electrical energy causes a joule heating effect that melts the soil during processing. Any contaminants released from the melt are collected and routed to an off-gas treatment system. A stable and durable glass block is produced which chemically and physically encapsulates any residual waste components. In situ vitrification has been developed for the potential application to radioactive wastes, specifically, contaminated soil sites; however, it could possibly be applied to hazardous chemical and buried munitions waste sites. The technology has been developed and demonstrated to date through a series of 21 engineering-scale tests [producing 50 to 1000 kg (100 to 2000 lb) blocks] and seven pilot-scale tests [producing 9000 kg (20,000 lb) blocks], the most recent of which illustrated treatment of actual radioactively contaminated soil. Testing with some organic materials has shown relatively complete thermal destruction and incineration. Further experiments have documented the insensitivity of in situ vitrification to soil characteristics such as fusion temperature, specific heat, thermal conductivity, electrical resistivity, and moisture content. Soil inclusions such as metals, cements, ceramics, and combustibles normally present only minor process limitations. Costs for hazardous waste applications are estimated to be less than $175/m 3 ($5.00/ft 3 ) of material vitrified. For many applications, in situ vitrification can provide a cost-effective alternative to other disposal options. 13 references, 4 figures, 1 table

  14. Phytoremediation and land management of radionuclide contaminated areas

    International Nuclear Information System (INIS)

    Vanek, T.; Valenova, S.; Soudek, P.

    2006-01-01

    A study was conducted to examine the feasibility of using radiophytoremediation for wastewater treatment, where the conditions of contaminants can be similar to hydroponic arrangement. Due to the fact that large doses of radiation can cause cellular damage, the remediation of radionuclides from the environment is important for human health. These high risk pollutants are introduced into the environment at uranium ore processing factories, nuclear power plants, and nuclear bomb testing sites. Following the Chernobyl accident in 1986, various studies were conducted to analyze the dynamic of 137 Cs radionuclide in natural and semi-natural environments. The use of plants to clean up soils, sediments, surface and ground waters contaminated by radionuclides or toxic elements has been extensively tested. This study in particular, examined the uptake, translocation and distribution of 137 Cs, 90 Sr and 125 I uptake from a radioactive hydroponic solution. It also examined the activity distribution within different plant tissues. The influence of K + , Ca 2+ and NH 4 + on 137 Cs and 90 Sr uptake and accumulation by sunflowers was also studied in order to evaluate the effects of these ions that are normally present in the soil. The study examined which plant species could grow in contaminated areas and accumulate large amounts of radionuclides which would be suitable for radiophytoremediation purposes. Approximately 44 plant species were tested in greenhouse experiments, field studies and constructed wetlands. It was concluded that for soil-cleaning purposes, the solubility of the contaminant and its mobility in soil is the main limiting factor along with the extent of root-zone of certain plant species

  15. Measurement of air contamination in different wards of public sector hospital, Sukkur.

    Science.gov (United States)

    Memon, Badaruddin AllahDino; Bhutto, Gul Hassan; Rizvi, Wajid Hussain

    2016-11-01

    The aim of this study was to evaluate and assess the index of bacterial contamination in different wards of the Public Sector Hospital of Sukkur (Teaching) Pakistan; whether or not the air contamination was statistically different from the acceptable level using active and passive sampling. In addition to this main hypothesis, other investigations included: occurrence of the most common bacteria, whether or not the bacterial contamination in the wards was a persistent problem and identification of the effective antibiotics against the indentified bacteria. The evidence sought based on the One Sample T test suggests that there is a (statistically) significant difference between the observed (higher) than the acceptance level (pcontamination problem was persistent as there was no significant difference among observed contamination of all three visits at (p>0.01) and the result of antibiotic susceptibility test highlights sensitivity and resistance level of antibiotics for the indentified bacteria.

  16. Screening of plants for phytoremediation of oil-contaminated soil.

    Science.gov (United States)

    Ikeura, Hiromi; Kawasaki, Yu; Kaimi, Etsuko; Nishiwaki, Junko; Noborio, Kosuke; Tamaki, Masahiko

    2016-01-01

    Several species of ornamental flowering plants were evaluated regarding their phytoremediation ability for the cleanup of oil-contaminated soil in Japanese environmental conditions. Thirty-three species of plants were grown in oil-contaminated soil, and Mimosa, Zinnia, Gazania, and cypress vine were selected for further assessment on the basis of their favorable initial growth. No significant difference was observed in the above-ground and under-ground dry matter weight of Gazania 180 days after sowing between contaminated and non-contaminated plots. However, the other 3 species of plants died by the 180th day, indicating that Gazania has an especially strong tolerance for oil-contaminated soil. The total petroleum hydrocarbon concentration of the soils in which the 4 species of plants were grown decreased by 45-49% by the 180th day. Compared to an irrigated plot, the dehydrogenase activity of the contaminated soil also increased significantly, indicating a phytoremediation effect by the 4 tested plants. Mimosa, Zinnia, and cypress vine all died by the 180th day after seeding, but the roots themselves became a source of nutrients for the soil microorganisms, which led to a phytoremediation effect by increase in the oil degradation activity. It has been indicated that Gazania is most appropriate for phytoremediation of oil-contaminated soil.

  17. Hydrochemistry and Characteristics of Groundwater: Case Study Water Contamination at Citarum River Upstream

    Directory of Open Access Journals (Sweden)

    Mohamad Sapari Dwi Hadian

    2017-12-01

    Full Text Available Rancaekek and Sayang area, West Java, are the area where many industrial factories are located.Thus, the region becomes the targeted destination for industrial development.The  population in the area is rising due to the growth of industries causing the regional development becomes uncontrollable. In addition, the constant increment of waste and also poor-coordinated disposal systems may result in groundwater contamination in the areas. The rapid growth of the area increase the need for groundwater as well as the need for more research about contamination at Rancaekek and Sayang. The research aims to explore the spread of groundwater contamination in the area. The research method is carried out based on the analysis of Geological Mapping, Hydrogeological Mapping and chemical characteristics of the groundwater in the area. Chemical analyses of the groundwater were conducted through laboratory test of groundwater samples at specific spots of dug wells. The lab test results were further analyzed to determine the contamination zone. The findings reveal that the distribution of contamination in the area follow the shallow ground water flow patterns, the water contamination contains heavy metal and there is degradation of soil fertility. The findings suggest the stakeholders to delineate the contaminated area, and increase the dissemination of environmental awareness.

  18. Emerging Contaminants and Federal Facility Contaminants of Concern

    Science.gov (United States)

    This page links to fact sheets summarizing contaminants of concern and emerging contaminants that present unique issues and challenges to the environmental community in general and to FFRRO in particular.

  19. Verification of radioactive contamination surveys for practical use in biological research centres

    International Nuclear Information System (INIS)

    Macias, M.T.; Requejo, C.; Ruiz, M.; Pina, R.

    2006-01-01

    Unsealed sources are commonly used in science research laboratories. Their manipulation may imply a radioactive contamination hazard. Therefore, adequate and sensitive survey meters must be available, and must have an effective and accurate response to intensity and type of radiation emitted by the used radionuclides to identify and quantify the possible contamination and then be able to avoid any associated or unwanted consequences that may arise. Periodic surveys are performed to show control, any time, any place radioactive contamination is suspected, and to ensure radioisotopes are being used safely. The immediate work areas must be often checked with portable survey monitors, including the entire lab and particularly bench tops, personnel protective equipment or solely designated equipment for isotope use (micro-fuges, water baths, incubators). These are carried out with portable survey instruments like Geiger-Muller tubes, proportional counters and scintillation detectors that provide direct or indirect measurements capabilities. The Radiation Safety Office (R.S.O.) as well as the radioactive compounds working laboratories at the Instituto de Inv. Biomedicas 'A. Sols' (Madrid-Spain) are provided with an adequate radiation measurement instrument. But, before a portable survey instrument is used, several quality checks should be made (batteries, calibration sticker), and the instrument response should be tested with a check source. This paper aims at determining, with a R.S.O. procedure, these surveys working parameters -detection efficiency, calibration factors and minimum detectable activities-, using reference checking sources ( 14 C, 36 Cl, and 90 Sr/ 90 Y) with known radioactivity covering the energy range of beta emitting isotopes used in biological research. No gamma portable monitors have been tested for the R.S.O. has no gamma checking sources. Therefore, 58 beta monitors were tested, obtaining t he efficiency values, the calibration factors (Bq cm-2 s

  20. Remediation aspect of microbial changes of plant rhizosphere in mercury contaminated soil.

    Science.gov (United States)

    Sas-Nowosielska, Aleksandra; Galimska-Stypa, Regina; Kucharski, Rafał; Zielonka, Urszula; Małkowski, Eugeniusz; Gray, Laymon

    2008-02-01

    Phytoremediation, an approach that uses plants to remediate contaminated soil through degradation, stabilization or accumulation, may provide an efficient solution to some mercury contamination problems. This paper presents growth chamber experiments that tested the ability of plant species to stabilize mercury in soil. Several indigenous herbaceous species and Salix viminalis were grown in soil collected from a mercury-contaminated site in southern Poland. The uptake and distribution of mercury by these plants were investigated, and the growth and vitality of the plants through a part of one vegetative cycle were assessed. The highest concentrations of mercury were found at the roots, but translocation to the aerial part also occurred. Most of the plant species tested displayed good growth on mercury contaminated soil and sustained a rich microbial population in the rhizosphere. The microbial populations of root-free soil and rhizosphere soil from all species were also examined. An inverse correlation between the number of sulfur amino acid decomposing bacteria and root mercury content was observed. These results indicate the potential for using some species of plants to treat mercury contaminated soil through stabilization rather than extraction. The present investigation proposes a practical cost-effective temporary solution for phytostabilization of soil with moderate mercury contamination as well as the basis for plant selection.

  1. Design and Development of Hand and Foot Contamination Monitor

    Directory of Open Access Journals (Sweden)

    F. Akter

    2014-08-01

    Full Text Available A hand and foot contamination monitor is a health physics instrument to provide detection and measurement of beta-gamma contamination on the palm of each hand and on the bottom surface of both feet/shoes. There are four channels of detection for two hands and two feet. Four G-M detectors have been used in a single unit to cover the whole area of hand and feet. A regulated high voltage DC power supply (900 V has been designed using the PIC12F675 microcontroller to operate the pancake Geiger-Müller detectors. The reading is displayed on a linearly scaled 0-100 Bq/cm2 analog panel meter. The monitor detects beta–gamma radiation emitted by radioactive materials, and if the detected value exceeds a preset level, the monitor sounds an alarm and displays a reading in the respective panel meter. Indicator lamps are used to show the status of contamination. The performance of the system has been tested by using pulse generator and by flat surface radioactive calibration sources. Electronic linearity, detection efficiency, response to the contamination, calibration factor and percentage of error has been measured. Test results were satisfactory and the present system can be used instead of similar imported instruments.

  2. Glovebox characterization and barrier integrity testing using fluorescent powder

    International Nuclear Information System (INIS)

    Wahlquist, D.R.

    1996-01-01

    This paper presents a method for characterizing the spread of contamination and testing the barrier integrity of a new glovebox during material transfer operations and glove change-outs using fluorescent powder. Argonne National Laboratory-West has performed this test on several new gloveboxes prior to putting them into service. The test is performed after the glovebox has been leak tested and all systems have been verified to be operational. The purpose of the test is to show that bag-in/bag-out operations and glove change-outs can be accomplished without spreading the actual contaminated material to non-contaminated areas. The characterization test also provides information as to where contamination might be expected to build-up during actual operations. The fluorescent powder is used because it is easily detectable using an ultra-violet light and disperses in a similar fashion to radioactive material. The characterization and barrier integrity test of a glovebox using fluorescent powder provides a visual method of determining areas of potential contamination accumulation and helps evaluate the ability to perform clean transfer operations and glove change-outs

  3. Biodegradation of uranium-contaminated waste oil

    International Nuclear Information System (INIS)

    Hary, L.F.

    1983-01-01

    The Portsmouth Gaseous Diffusion Plant routinely generates quantities of uranium-contaminated waste oil. The current generation rate of waste oil is approximately 2000 gallons per year. The waste is presently biodegraded by landfarming on open field soil plots. However, due to the environmental concerns associated with this treatment process, studies were conducted to determine the optimum biodegradation conditions required for the destruction of this waste. Tests using respirometric flasks were conducted to determine the biodegradation rate for various types of Portsmouth waste oil. These tests were performed at three different loading rates, and on unfertilized and fertilized soil. Additional studies were conducted to evaluate the effectiveness of open field landfarming versus treatment at a greenhouse-like enclosure for the purpose of maintaining soil temperatures above ambient conditions. The respirometric tests concluded that the optimum waste oil loading rate is 10% weight of oil-carbon/weight of soil (30,600 gallons of uranium-contaminated waste oil/acre) on soils with adjusted carbon:nitrogen and carbon:phosphorus ratios of 60:1 and 800:1, respectively. Also, calculational results indicated that greenhouse technology does not provide a significant increase in biodegradation efficiency. Based on these study results, a 6300 ft. 2 abandoned anaerobic digester sludge drying bed is being modified into a permanent waste oil biodegradation facility. The advantage of using this area is that uranium contamination will be contained by the bed's existing leachate collection system. This modified facility will be capable of handling approximately 4500 gallons of waste oil per year; accordingly current waste generation quantities will be satisfactorily treated. 15 refs., 14 figs., 4 tabs

  4. Hybrid electrokinetic method applied to mix contaminated soil

    Energy Technology Data Exchange (ETDEWEB)

    Mansour, H.; Maria, E. [Dept. of Building Civil and Environmental Engineering, Concordia Univ., Montreal (Canada)

    2001-07-01

    Several industrials and municipal areas in North America are contaminated with heavy metals and petroleum products. This mix contamination presents a particularly difficult task for remediation when is exposed in clayey soil. The objective of this research was to find a method to cleanup mix contaminated clayey soils. Finally, a multifunctional hybrid electrokinetic method was investigated. Clayey soil was contaminated with lead and nickel (heavy metals) at the level of 1000 ppm and phenanthrene (PAH) of 600 ppm. Electrokinetic surfactant supply system was applied to mobilize, transport and removal of phenanthrene. A chelation agent (EDTA) was also electrokinetically supplied to mobilize heavy metals. The studies were performed on 8 lab scale electrokinetic cells. The mix contaminated clayey soil was subjected to DC total voltage gradient of 0.3 V/cm. Supplied liquids (surfactant and EDTA) were introduced in different periods of time (22 days, 42 days) in order to optimize the most excessive removal of contaminants. The ph, electrical parameters, volume supplied, and volume discharged was monitored continuously during each experiment. At the end of these tests soil and cathalyte were subjected to physico-chemical analysis. The paper discusses results of experiments including the optimal energy use, removal efficiency of phenanthrene, as well, transport and removal of heavy metals. The results of this study can be applied for in-situ hybrid electrokinetic technology to remediate clayey sites contaminated with petroleum product mixed with heavy metals (e.g. manufacture Gas Plant Sites). (orig.)

  5. Explosive Contamination from Substrate Surfaces: Differences and Similarities in Contamination Techniques Using RDX and C-4

    Science.gov (United States)

    Miller, C. J.; Yoder, T. S.

    2010-06-01

    Explosive trace detection equipment has been deployed to airports for more than a decade. During this time, the need for standardized procedures and calibrated trace amounts for ensuring that the systems are operating properly and detecting the correct explosive has been apparent but a standard representative of a fingerprint has been elusive. Standards are also necessary to evaluate instrumentation in the laboratories during development and prior to deployment to determine sample throughput, probability of detection, false positive/negative rates, ease of use by operator, mechanical and/or software problems that may be encountered, and other pertinent parameters that would result in the equipment being unusable during field operations. Since many laboratories do not have access to nor are allowed to handle explosives, the equipment is tested using techniques aimed at simulating the actual explosives fingerprint. This laboratory study focused on examining the similarities and differences in three different surface contamination techniques that are used to performance test explosive trace detection equipment in an attempt to determine how effective the techniques are at replicating actual field samples and to offer scenarios where each contamination technique is applicable. The three techniques used were dry transfer deposition of standard solutions using the Transportation Security Laboratory’s (TSL) patented dry transfer techniques (US patent 6470730), direct deposition of explosive standards onto substrates, and fingerprinting of actual explosives onto substrates. RDX was deposited on the surface of one of five substrates using one of the three different deposition techniques. The process was repeated for each substrate type using each contamination technique. The substrate types used were: 50% cotton/50% polyester as found in T-shirts, 100% cotton with a smooth surface such as that found in a cotton dress shirt, 100% cotton on a rough surface such as that

  6. 40 CFR 141.62 - Maximum contaminant levels for inorganic contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant levels for inorganic contaminants. 141.62 Section 141.62 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Water Regulations: Maximum Contaminant Levels and Maximum Residual Disinfectant Levels § 141.62 Maximum...

  7. Radioactive surface contamination monitors

    International Nuclear Information System (INIS)

    Aoyama, Kei; Minagoshi, Atsushi; Hasegawa, Toru

    1994-01-01

    To reduce radiation exposure and prevent contamination from spreading, each nuclear power plant has established a radiation controlled area. People and articles out of the controlled area are checked for the surface contamination of radioactive materials with surface contamination monitors. Fuji Electric has repeatedly improved these monitors on the basis of user's needs. This paper outlines typical of a surface contamination monitor, a personal surface contamination monitor, an article surface contamination monitor and a laundry monitor, and the whole-body counter of an internal contamination monitor. (author)

  8. Testing the role of contaminants in depressing avian numbers Evaluando el rol de los contaminantes sobre la disminución del número de aves

    Directory of Open Access Journals (Sweden)

    WILLIAM H. KARASOV

    2000-09-01

    Full Text Available Environmental contaminants are ubiquitous and so are often key suspects in cases of lagging wildlife populations. How do we test hypotheses about cause-effect linkages between contaminants and wildlife health? We present three case studies in which different approaches were used to test hypotheses about effects of contaminants on wildlife. The cases involve the possible impacts of (1 polychlorinated biphenyl on Lake Superior bald eagles (Haliaeetus leucocephalus; (2 dioxin on osprey (Pandion halieatus; and (3 methyl mercury on common loons (Gavia immer. The different approaches were dictated by legal, logistic, and financial limitations, but the relative strengths of experimental and mechanistic approaches over correlative approaches is underscored. For all three species, the simple correlation between a single contaminant and performance was confounded by covariation with other types of contaminants and/or natural ecological factors such as food availability and predationLos contaminantes ambientales son ubicuos y a menudo los principales sospechosos en los casos de disminución en las poblaciones de fauna silvestre. ¿Cómo probamos las hipótesis sobre las relaciones causa - efecto entre los contaminantes y la salud de la fauna silvestre? Presentamos tres estudios de caso en que se usaron diferentes aproximaciones para someter a prueba las hipótesis sobre los efectos de los contaminantes sobre la fauna silvestre. Los casos involucran los posibles impactos de (1 el bifenilos policlorados en el águila calva (Haliaeetus leucocephalus en el Lago Superior; (2 las dioxinas sobre el águila pescadora (Pandion halieatus; y (3 el mercurio de metilo en colimbo grande (Gavia immer. Las limitaciones legales, logísticas y financieras, determinaron diferentes aproximaciones en estos estudios, pero se destaca que la fuerza relativa de las aproximaciones experimentales y mecanicistas es superior a la de un acercamiento correlacional. Se demuestra que, en

  9. Hanford Site physical separations CERCLA treatability test plan

    International Nuclear Information System (INIS)

    1992-03-01

    This test plan describes specifications, responsibilities, and general procedures to be followed to conduct a physical separations soil treatability test in the North Process Pond of the 300-FF-1 Operable Unit at the Hanford Site, Washington. The objective of this test is to evaluate the use of physical separation systems as a means of concentrating chemical and radioactive contaminants into fine soil fractions and thereby minimizing waste volumes. If successful the technology could be applied to clean up millions of cubic meters of contaminated soils in waste sites at Hanford and other sites. It is not the intent of this test to remove contaminated materials from the fine soils. Physical separation is a simple and comparatively low cost technology to potentially achieve a significant reduction in the volume of contaminated soils. Organic contaminants are expected to be insignificant for the 300-FF-I Operable Unit test, and further removal of metals and radioactive contaminants from the fine fraction of soils will require secondary treatment such as chemical extraction, electromagnetic separation, or other technologies. Additional investigations/testing are recommended to assess the economic and technical feasibility of applying secondary treatment technologies, but are not within the scope of this test. This plan provides guidance and specifications for the treatability test to be conducted as a service contract. More detailed instructions and procedures will be provided as part of the vendors (sellers) proposal. The procedures will be approved by Westinghouse Hanford Company (Westinghouse Hanford) and finalized by the seller prior to initiating the test

  10. Records of contaminant input to San Francisco Bay

    International Nuclear Information System (INIS)

    Geen, A. van; Luoma, S.N.; Hornberger, M.; Fuller, C.; Pereira, W.; Hostettler, F.; Kvenvolden, K.; Anima, R.; Ritson, P.; Flegal, A.R.

    1994-01-01

    San Francisco Bay, one of the few large estuaries on the West Coast of North America, was subjected to great change as mining, agriculture, industrialization and urbanization accelerated after 1849, and river flows were diverted for agriculture. Trends in contamination were evident in sediment cores analyzed from seven sites. Sedimentation rates increased with human activities. Industrialization was a greater source of contamination than mining. Nearest the mouth of the estuary, concentrations of Hg, Cu, Zn, Pb and PAH began to increase around 1900. Isotopes of Pb indicated sediments were affected by a mixture of atmospheric, industrial and erosional inputs. Peaks in some contaminants were evident since the 1950s, notably Ag, Cd in water (as recorded in foraminifers tests), and DDT. Chromium and vanadium were naturally enriched throughout the cores. Declines in metal concentrations in surface sediments were not evident. Vertical mixing could delay response of sediments to changed metal inputs. Nearer the head of the estuary, contaminant concentrations, TOC and indicators of terrigenous carbon increased sharply where 137 Cs and 239,240 Pu was present (presumably post-1950). Diversion of river flows may have affected accumulation of sediments contaminated by post-war industrialization and acceleration of agricultural development

  11. Contaminant bacteria in traditional-packed honey

    Directory of Open Access Journals (Sweden)

    Hening Tjaturina Pramesti

    2007-03-01

    Full Text Available Honey may be contaminated by microorganisms during its harvesting, processing, and packaging. Honey selected for clinical purposes must safe, sterile, and contain antimicrobial activity, so it must be evaluated using laboratory testing. The aim of this descriptive laboratory study was to isolate and identify the bacterial contaminant in the traditional-packed honey dealing with the use of honey for medical purposes. the colony forming units of honey sample cultured on blood agar were counted using Stuart bacterial colony counter. The suspected bacterial colonies were isolated and identified based on cultural morphology characteristics. The isolates of suspected bacterial colonies were stained according to Gram and Klein method and then were examined by the biochemical reaction. The results showed that there were two contaminant bacteria. Gram-positive cocci which were presumptively identified as coagulase-negative Staphylococci and gram-positive rods which were presumptively identified as Bacillus subtilis. In conclusion, the contaminant bacteria were regarded as low pathogen bacteria. The subtilin enzyme of B subtilis may cause an allergic reaction and coagulase-negative Staphylococci, Staphylococcus epidermidis is also an opportunist pathogen. Inevitably, for medical purposes, traditional-packed honey must be well filtered, water content above 18%, and standardized sterilization without loss of an antibacterial activity or change in properties.

  12. Metabolic profiling of meat: assessment of pork hygiene and contamination with Salmonella typhimurium.

    Science.gov (United States)

    Xu, Yun; Cheung, William; Winder, Catherine L; Dunn, Warwick B; Goodacre, Royston

    2011-02-07

    Spoilage in meat is the result of the action of microorganisms and results in changes of meat and microbial metabolism. This process may include pathogenic food poisoning bacteria such as Salmonella typhimurium, and it is important that these are differentiated from the natural spoilage process caused by non-pathogenic microorganisms. In this study we investigated the application of metabolic profiling using gas chromatography-mass spectrometry, to assess the microbial contamination of pork. Metabolite profiles were generated from microorganisms, originating from the natural spoilage process and from the artificial contamination with S. typhimurium. In an initial experiment, we investigated changes in the metabolic profiles over a 72 hour time course at 25 °C and established time points indicative of the spoilage process. A further experiment was performed to provide in-depth analysis of the metabolites characteristic of contamination by S. typhimurium. We applied a three-way PARAllel FACtor analysis 2 (PARAFAC2) multivariate algorithm to model the metabolic profiles. In addition, two univariate statistical tests, two-sample Wilcoxon signed rank test and Friedman test, were employed to identify metabolites which showed significant difference between natural spoiled and S. typhimurium contaminated samples. Consistent results from the two independent experiments were obtained showing the discrimination of the metabolic profiles of the natural spoiled pork chops and those contaminated with S. typhimurium. The analysis identified 17 metabolites of significant interest (including various types of amino acid and fatty acid) in the discrimination of pork contaminated with the pathogenic microorganism.

  13. Direct contamination - seasonality

    International Nuclear Information System (INIS)

    Aarkrog, A.

    1994-01-01

    Direct contamination is the primary pathway to terrestrial vegetation in the first period after an activity release to the atmosphere. All radionuclides are able to be transferred via this pathway. Deposition, interception and retention are the three processes involved in direct contamination of crops. Wet deposition is more important than dry deposition in temperature regions. Resuspension and rainsplash both belong to secondary direct deposition and became evident for e.g. radiocaesium after the Chernobyl accident. Seasonality is the varying response to radioactive contamination of crops according to the time of the year when the contamination occurs. Shortlived radionuclides (as 131 I) and those that mainly enter the foodchain by direct contamination (e.g. 137 Cs) are especially important in this connection. In particular, the contamination of cereal crops is influenced by seasonality. As a result of seasonality the impact of the Chernobyl accident on the radioactive contamination of human diet was for the same deposition density higher in southern than in northern Europe. (orig.)

  14. Permeability response of oil-contaminated compacted clays

    International Nuclear Information System (INIS)

    Silvestri, V.; Mikhail, N.; Soulie, M.

    1997-01-01

    This paper presents the results of a laboratory investigation on the behavior of motor oil-contaminated, partially saturated compacted clays. For the study, both a natural clay and an artificially purified kaolinite, contaminated with 0 to 8% of motor oil, were firstly compacted following the ASTM standard procedure. Secondly, permeability tests were carried out in a triaxial cell on 10 cm-diameter compacted clay specimens. The results of the investigation indicate that increasing percentages of motor oil decrease both the optimum water content and the optimum dry density of the two clays. However, whereas the optimum water content on the average decreases by about 6% when the percentage contamination increases from 0 to 8%, the corresponding decrease in the optimum dry density is less than 3%. Even though the optimum dry density decreases as the percentage of oil increases from 0 to 8%, there is, however, a range in oil content varying between 2 and 4% for which the optimum dry density is slightly greater than that of the untreated soils. As far as the permeability tests are concerned, the results indicate that as the percentage of oil increases, the coefficient of permeability decreases substantially, especially for clay specimens which were initially compacted on the dry side of optimum

  15. Contamination transfers during fuel transport cask loading. A concrete situation

    International Nuclear Information System (INIS)

    Fournel, B.; Turchet, J.P.; Faure, S.; Allinei, P.G.; Briquet, L.; Baubet, D.

    2002-01-01

    In 1998, a number of contamination cases detected during fuel shipments have been pointed out by the french nuclear safety authority. Wagon and casks external surfaces were partly contaminated upon arrival in Valognes railway terminal. Since then, measures taken by nuclear power plants operators in France and abroad solved the problem. In Germany, a report analyzing the situation in depth has been published in which correctives actions have been listed. In France, EDF launched a large cleanliness program (projet proprete radiologique) in order to better understand contamination transfers mechanisms during power plants exploitation and to list remediation actions to avoid further problems. In this context, CEA Department for Wastes Studies at Cadarache (CEA/DEN/DED) was in charge of a study about contamination transfers during fuel elements loading operations. It was decided to lead experiments for a concrete case. The loading of a transport cask at Tricastin-PWR-1 was followed in november 2000 and different analysis comprising water analysis and smear tests analysis were carried out and are detailed in this paper. Results are discussed and qualitatively compared to those obtained in Philippsburg-BWR, Germany for a similar set of tests. (authors)

  16. Biochar- and phosphate-induced immobilization of heavy metals in contaminated soil and water: implication on simultaneous remediation of contaminated soil and groundwater.

    Science.gov (United States)

    Liang, Yuan; Cao, Xinde; Zhao, Ling; Arellano, Eduardo

    2014-03-01

    Long-term wastewater irrigation or solid waste disposal has resulted in the heavy metal contamination in both soil and groundwater. It is often separately implemented for remediation of contaminated soil or groundwater at a specific site. The main objective of this study was to demonstrate the hypothesis of simultaneous remediation of both heavy metal contaminated soil and groundwater by integrating the chemical immobilization and pump-and-treat methods. To accomplish the objective, three experiments were conducted, i.e., an incubation experiment was first conducted to determine how dairy-manure-derived biochar and phosphate rock tailing induced immobilization of Cd in the Cd-contaminated soils; second, a batch sorption experiment was carried out to determine whether the pre-amended contaminated soil still had the ability to retain Pb, Zn and Cd from aqueous solution. BCR sequential extraction as well as XRD and SEM analysis were conducted to explore the possible retention mechanism; and last, a laboratory-scale model test was undertaken by leaching the Pb, Zn, and Cd contaminated groundwater through the pre-amended contaminated soils to demonstrate how the heavy metals in both contaminated soil and groundwater were simultaneously retained and immobilized. The incubation experiment showed that the phosphate biochar were effective in immobilizing soil Cd with Cd concentration in TCLP (toxicity characteristics leaching procedure) extract reduced by 19.6 % and 13.7 %, respectively. The batch sorption experiment revealed that the pre-amended soil still had ability to retain Pb, Zn, and Cd from aqueous solution. The phosphate-induced metal retention was mainly due to the metal-phosphate precipitation, while both sorption and precipitation were responsible for the metal stabilization in the biochar amendment. The laboratory-scale test demonstrated that the soil amended with phosphate removed groundwater Pb, Zn, and Cd by 96.4 %, 44.6 %, and 49.2 %, respectively, and the

  17. Residual radioactive contamination of the test site at Emu from nuclear weapons tests conducted in 1953

    International Nuclear Information System (INIS)

    Maclagan, D.S.; Cooper, M.B.; Duggleby, J.C.

    1979-08-01

    The detailed distributions and soil concentrations of long-lived radionuclides remaining from nuclear weapons trials conducted at Emu in October 1953, are presented. Significant radiation levels due to long-lived neutron activation products in soil, 60 Co and 152 Eu, occur only in the immediate vicinity of the ground zeros of TOTEM 1 and TOTEM 2. It is shown that the levels of contamination due to fallout products in the soil are well below those which would constitute a health hazard to occupants of the area

  18. Groundwater fluoride contamination: A reappraisal

    Directory of Open Access Journals (Sweden)

    Amlan Banerjee

    2015-03-01

    Full Text Available Dissolution of fluorite (CaF2 and/or fluorapatite (FAP [Ca5(PO43F], pulled by calcite precipitation, is thought to be the dominant mechanism responsible for groundwater fluoride (F− contamination. Here, one dimensional reactive–transport models are developed to test this mechanism using the published dissolution and precipitation rate kinetics for the mineral pair FAP and calcite. Simulation results correctly show positive correlation between the aqueous concentrations of F− and CO32− and negative correlation between F− and Ca2+. Results also show that precipitation of calcite, contrary to the present understanding, slows down the FAP dissolution by 106 orders of magnitude compared to the FAP dissolution by hydrolysis. For appreciable amount of fluoride contamination rock–water interaction time must be long and of order 106 years.

  19. In situ vitrification: Test results for a contaminated soil melting process

    International Nuclear Information System (INIS)

    Buelt, J.L.; Bonner, W.F.

    1989-04-01

    Pacific Northwest Laboratory (PNL) is developing in situ vitrification (ISV), a remedial action process for treating contaminated soils. In situ vitrification is a thermal treatment process that converts contaminated soil into a chemically inert and stable glass and crystalline product. Figure 1 depicts the process. A square array of four molybdenum/graphite electrodes is inserted into the ground to the desired treatment depth. Because soil is not electrically conductive when the moisture has been driven off, a conductive mixture of flaked graphite and glass frit is placed between the pairs of electrodes as a starter path. An electrical potential is applied to the electrodes to establish an electric current in the starter path. The resultant power heats the starter path and surrounding soil to 2000 degree C, well above the initial soil-melting temperature of 1100 to 1400 degree C. The graphite starter path is eventually consumed by oxidation, and the current is transferred to the molten soil, which is electrically conductive. As the molten or vitrified zone grows, it incorporates radionuclides and nonvolatile hazardous elements, such as heavy metals, and destroys organic components by pyrolysis. The pyrolyzed byproducts migrate to the surface of the vitrified zone, where they burn in the presence of oxygen. A hood placed over the area being vitrified directs the gaseous effluents to an off-gas treatment system. 5 refs., 1 fig., 1 tab

  20. Environmental assessment for double tracks test site, Nevada Test Site, Nye County, Nevada

    International Nuclear Information System (INIS)

    1996-04-01

    The U.S. Department of Energy, Nevada Operations Office (DOE/NV), with appropriate approvals from the U.S. Air Force (USAF), proposes to conduct environmental restoration operations at the Double Tracks test site located on the Nellis Air Force Range (NAFR) in Nye County, Nevada. This environmental assessment (EA) evaluates the potential environmental consequences of four alternative actions for conducting the restoration operation and of the no action alternative. The EA also identifies mitigation measures, where appropriate, designed to protect natural and cultural resources and reduce impacts to human health and safety. The environmental restoration operation at the Double Tracks test site would serve two primary objectives. First, the proposed work would evaluate the effectiveness of future restoration operations involving contamination over larger areas. The project would implement remediation technology options and evaluate how these technologies could be applied to the larger areas of contaminated soils on the Nevada Test Site (NTS), the Tonopah Test Range (TTR), and the NAFR. Second, the remediation would provide for the removal of plutonium contamination down to or below a predetermined level which would require cleanup of 1 hectare (ha) (2.5 acres), for the most likely case, or up to 3.0 ha (7.4 acres) of contaminated soil, for the upper bounding case

  1. Assessing and minimizing contamination in time of flight based validation data

    Science.gov (United States)

    Lennox, Kristin P.; Rosenfield, Paul; Blair, Brenton; Kaplan, Alan; Ruz, Jaime; Glenn, Andrew; Wurtz, Ronald

    2017-10-01

    Time of flight experiments are the gold standard method for generating labeled training and testing data for the neutron/gamma pulse shape discrimination problem. As the popularity of supervised classification methods increases in this field, there will also be increasing reliance on time of flight data for algorithm development and evaluation. However, time of flight experiments are subject to various sources of contamination that lead to neutron and gamma pulses being mislabeled. Such labeling errors have a detrimental effect on classification algorithm training and testing, and should therefore be minimized. This paper presents a method for identifying minimally contaminated data sets from time of flight experiments and estimating the residual contamination rate. This method leverages statistical models describing neutron and gamma travel time distributions and is easily implemented using existing statistical software. The method produces a set of optimal intervals that balance the trade-off between interval size and nuisance particle contamination, and its use is demonstrated on a time of flight data set for Cf-252. The particular properties of the optimal intervals for the demonstration data are explored in detail.

  2. Contamination vs. Exposure

    Science.gov (United States)

    ... into the environment can cause air, water, surfaces, soil, plants, buildings, people, or animals to become contaminated. ... water to remove contamination. This process is called decontamination. Try to avoid spreading contamination to parts of ...

  3. Contamination of clothing and other items by sweat during exercise 201Tl myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Yokoo, Shigeki; Niio, Yasuo; Yamamoto, Tomoaki; Miyashita, Makoto

    1999-01-01

    We measured the radioactivity on patient's upper and lower garments, towels, broad sashes for the bust, and electrodes contaminated by sweat due to exercise 201 Tl myocardial perfusion scintigraphy. In measuring activity, a scintillation survey meter adjusted to the energy of 201 Tl was used. In measuring the radioactivity of clothing, more than 4 Bq/cm 2 was considered to be a significant level of contamination. We detected contamination in 30% of upper garments and towels, 19% of broad sashes, 8% of lower garments and 4% of electrodes. Among these materials, several items of clothing and other items showed contamination exceeding 40 Bq/cm 2 . Towels were remarkably contaminated, with one towel showing a maximum contamination level of 420 Bq/cm 2 . Examinations done by exercise 201 Tl myocardial perfusion scintigraphy often result in the contamination of clothing and other items through sweating. This contamination is especially common in summer, particularly in upper garments and towels. The contamination ratio for towels was over 50%. The contamination ratio increased as the level of exercise became more difficult. When the exercise load was more than 100 W, the contamination ratio was 50%. In cases of extreme contamination, images of contaminated upper garments could be obtained by the scintigraphy camera. The areas of high activity on the images seemed to correspond to areas of the body where sweating was profuse. Based on these results, we should pay close attention to the handling of clothing and other items used in exercise testing by 201 Tl myocardial perfusion scintigraphy and the points used in measuring contaminated clothing and other items after testing. (author)

  4. The extent of environmental and body contamination through aerosols by hydro-surgical debridement in the lumbar spine.

    Science.gov (United States)

    Putzer, David; Lechner, Ricarda; Coraca-Huber, Debora; Mayr, Astrid; Nogler, Michael; Thaler, Martin

    2017-06-01

    Surgical site infections occur in 1-6% of spinal surgeries. Effective treatment includes early diagnosis, parenteral antibiotics and early surgical debridement of the wound surface. On a human cadaver, we executed a complete hydro-surgery debridement including a full surgical setup such as draping. The irrigation fluid was artificially contaminated with Staphylococcus aureus (ATCC 6538). Surveillance cultures were used to detect environmental and body contamination of the surgical team. For both test setups, environmental contamination was observed in an area of 6 × 8 m. Both test setups caused contamination of all personnel present during the procedure and of the whole operating theatre. However, the concentration of contamination for the surgical staff and the environment was lower when an additional disposable draping device was used. The study showed that during hydro-surgery debridement, contaminated aerosols spread over the whole surgical room and contaminate the theatre and all personnel.

  5. Toxicity of contaminants in lagoons and pannes of the Indiana Dunes National Lakeshore

    International Nuclear Information System (INIS)

    Gillespie, R.; Speelman, J.; Stewart, P.M.

    1995-01-01

    Contaminants in water and sediments of lagoons and pannes were 2--90 times greater at sites adjacent to slag and coal piles than those at reference sites. One site (Lagoon-US5) had sediments with very high concentrations of toxic organics (e.g. naphthalene, phenanthrene, dibenzofuran). Although analyses indicated a gradient of contaminant concentration with distance from their sources, toxicity assays were somewhat equivocal. With the exception of less reproduction in Ceriodaphnia at one lagoon site (US3 = 0.55 of reference), survival of fathead minnows and reproduction in Ceriodaphnia in lagoon and panne waters varied independently of the contaminant concentration. In fact, there was better Ceriodaphnia reproduction in water from two contaminated sites (Lagoon-US5, Panne-WP1) than in water from reference sites. Fathead minnow survival, Ceriodaphnia survival, Ceriodaphnia reproduction, amphipod survival, and amphipod growth varied among sites in toxicity assays with sediments, 100% mortality of fatheads at Lagoon-US5, 100% mortality of Ceriodaphnia at Lagoon-US3, and less survival of fathead minnows at Lagoon-US3 indicate possible toxicity from contaminants in sediments at these sites. Of all organisms and end-points tested, Ceriodaphnia survival seemed to be most closely associated with concentrations of contaminants in lagoon water and sediments. Amphipod survival also varied with contaminants in sediments, however, survival in sediments of contaminated sites ranged only from 0.90--0.93 of reference sites. Although the results are not consistent among organisms, toxicity assays indicate that sediments from the lagoon site with the highest contaminants (Lagoon-US5) and possibly those from another contaminated lagoon site (Lagoon-US3) could be toxic to aquatic organisms. Water and sediments from contaminated panne sites do not appear to be toxic to aquatic test organisms

  6. Contamination Tracer Testing With Seabed Rock Drills: IODP Expedition 357

    Science.gov (United States)

    Orcutt, B.; Bergenthal, M.; Freudenthal, T.; Smith, D. J.; Lilley, M. D.; Schneiders, L.; Fruh-Green, G. L.

    2016-12-01

    IODP Expedition 357 utilized seabed rock drills for the first time in the history of the ocean drilling program, with the aim of collecting intact core of shallow mantle sequences from the Atlantis Massif to examine serpentinization processes and the deep biosphere. This new drilling approach required the development of a new system for delivering synthetic tracers during drilling to assess for possible sample contamination. Here, we describe this new tracer delivery system, assess the performance of the system during the expedition, provide an overview of the quality of the core samples collected for deep biosphere investigations based on tracer concentrations, and make recommendations for future applications of the system.

  7. Effect of Coal Contaminants on Solid Oxide Fuel System Performance and Service Life

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, Gopala N.; Jayaweera, Palitha; Perez, Jordi; Hornbostel, M.; Albritton, John R.; Gupta, Raghubir P.

    2007-10-31

    The U.S. Department of Energy’s SECA program envisions the development of high-efficiency, low-emission, CO2 sequestration-ready, and fuel-flexible technology to produce electricity from fossil fuels. One such technology is the integrated gasification-solid oxide fuel cell (SOFC) that produces electricity from the gas stream of a coal gasifier. SOFCs have high fuel-to-electricity conversion efficiency, environmental compatibility (low NOx production), and modularity. The primary objective of the Phase I study was to determine the sensitivity of the performance of solid oxide fuel cells to trace level contaminants present in a coal-derived gas stream in the temperature range 700° to 900°C. Laboratory-scale tests were performed with 1-inch diameter solid oxide fuel cells procured from InDec B.V., Netherlands. These cells produce 0.15, 0.27, and 0.35 W/cm2 at 700°, 750°, and 800°C, respectively, in a H2 anode feed and are expected to be stable within 10% of the original performance over a period of 2000 h. A simulated coal-derived gas containing 30.0% CO, 30.6% H2 11.8% CO2, 27.6% H2O was used at a rate of ~100 standard cm3/min to determine the effect of contaminants on the electrical performance of the cells. Alumina or zirconia components were used for the gas manifold to prevent loss of contaminants by reaction with the surfaces of the gas manifold Short-term accelerated tests were conducted with several contaminants including As, P, CH3Cl, HCl, Hg, Sb, and Zn vapors. In these tests, AsH3, PH3, Cd vapor and CH3Cl identified as the potential contaminants that can affect the electrical performance of SOFCs. The effect of some of these contaminants varied with the operating temperature. Cell failure due to contact break inside the anode chamber occurred when the cell was exposed to 10 ppm arsenic vapor at 800°C. The electrical performance of SOFC

  8. Application of carbon nanotubes to immobilize heavy metals in contaminated soils

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Martim P. S. R.; Correia, António Alberto S., E-mail: aalberto@dec.uc.pt [University of Coimbra, Department of Civil Engineering, CIEPQPF—Chemical Process Engineering and Forest Products Research Centre (Portugal); Rasteiro, Maria G. [University of Coimbra, Department of Chemical Engineering, CIEPQPF (Portugal)

    2017-04-15

    The contamination of soils with heavy metals is a growing concern in modern societies. To avoid the spread of contamination, soil stabilization techniques can be applied mixing materials with the soil in order to partially immobilize heavy metals. Carbon nanotubes (CNTs) are nanomaterials known for its exceptional properties, like high surface area and adsorption capacity. Due to these unique properties, the potential use of CNTs in heavy metal contaminated water has been studied, with very satisfactory results; however, their application in contaminated soils is practically unexplored. This experimental work is focused on studying the potential of using CNTs in soil remediation, especially to immobilize the heavy metals ions: lead (Pb{sup 2+}), copper (Cu{sup 2+}), nickel (Ni{sup 2+}), and zinc (Zn{sup 2+}), commonly present in contaminated soils. In order to avoid CNT agglomeration, which originates the loss of their beneficial properties, an aqueous suspension of CNTs was prepared using a non-ionic surfactant combined with ultrasonic energy to promote CNTs dispersion. Then, the soil, with and without the addition of CNTs, was subjected to adsorption tests to evaluate the CNT capacity to improve heavy metal immobilization. To validate the adsorption test results, permeability tests were executed, simulating the conditions of a real-case scenario. The results obtained led to the conclusion that the addition of a small amount of dispersed CNTs can successfully increase the adsorption capacity of the soil and consequently improve the immobilization of heavy metals in the soil matrix. The immobilization percentage varies with the different heavy metals under study.

  9. Application of carbon nanotubes to immobilize heavy metals in contaminated soils

    International Nuclear Information System (INIS)

    Matos, Martim P. S. R.; Correia, António Alberto S.; Rasteiro, Maria G.

    2017-01-01

    The contamination of soils with heavy metals is a growing concern in modern societies. To avoid the spread of contamination, soil stabilization techniques can be applied mixing materials with the soil in order to partially immobilize heavy metals. Carbon nanotubes (CNTs) are nanomaterials known for its exceptional properties, like high surface area and adsorption capacity. Due to these unique properties, the potential use of CNTs in heavy metal contaminated water has been studied, with very satisfactory results; however, their application in contaminated soils is practically unexplored. This experimental work is focused on studying the potential of using CNTs in soil remediation, especially to immobilize the heavy metals ions: lead (Pb"2"+), copper (Cu"2"+), nickel (Ni"2"+), and zinc (Zn"2"+), commonly present in contaminated soils. In order to avoid CNT agglomeration, which originates the loss of their beneficial properties, an aqueous suspension of CNTs was prepared using a non-ionic surfactant combined with ultrasonic energy to promote CNTs dispersion. Then, the soil, with and without the addition of CNTs, was subjected to adsorption tests to evaluate the CNT capacity to improve heavy metal immobilization. To validate the adsorption test results, permeability tests were executed, simulating the conditions of a real-case scenario. The results obtained led to the conclusion that the addition of a small amount of dispersed CNTs can successfully increase the adsorption capacity of the soil and consequently improve the immobilization of heavy metals in the soil matrix. The immobilization percentage varies with the different heavy metals under study.

  10. Application of carbon nanotubes to immobilize heavy metals in contaminated soils

    Science.gov (United States)

    Matos, Martim P. S. R.; Correia, António Alberto S.; Rasteiro, Maria G.

    2017-04-01

    The contamination of soils with heavy metals is a growing concern in modern societies. To avoid the spread of contamination, soil stabilization techniques can be applied mixing materials with the soil in order to partially immobilize heavy metals. Carbon nanotubes (CNTs) are nanomaterials known for its exceptional properties, like high surface area and adsorption capacity. Due to these unique properties, the potential use of CNTs in heavy metal contaminated water has been studied, with very satisfactory results; however, their application in contaminated soils is practically unexplored. This experimental work is focused on studying the potential of using CNTs in soil remediation, especially to immobilize the heavy metals ions: lead (Pb2+), copper (Cu2+), nickel (Ni2+), and zinc (Zn2+), commonly present in contaminated soils. In order to avoid CNT agglomeration, which originates the loss of their beneficial properties, an aqueous suspension of CNTs was prepared using a non-ionic surfactant combined with ultrasonic energy to promote CNTs dispersion. Then, the soil, with and without the addition of CNTs, was subjected to adsorption tests to evaluate the CNT capacity to improve heavy metal immobilization. To validate the adsorption test results, permeability tests were executed, simulating the conditions of a real-case scenario. The results obtained led to the conclusion that the addition of a small amount of dispersed CNTs can successfully increase the adsorption capacity of the soil and consequently improve the immobilization of heavy metals in the soil matrix. The immobilization percentage varies with the different heavy metals under study.

  11. Use of a midstream clean catch mobile application did not lower urine contamination rates in an ED.

    Science.gov (United States)

    Jacob, Mary S; Kulie, Paige; Benedict, Cameron; Ordoobadi, Alexander J; Sikka, Neal; Steinmetz, Erika; McCarthy, Melissa L

    2018-01-01

    Urine microscopy is a common test performed in emergency departments (EDs). Urine specimens can easily become contaminated by different factors, including the collection method. The midstream clean-catch (MSCC) collection technique is commonly used to reduce urine contamination. The urine culture contamination rate from specimens collected in our ED is 30%. We developed an instructional application (app) to show ED patients how to provide a MSCC urine sample. We hypothesized that ED patients who viewed our instructional app would have significantly lower urine contamination rates compared to patients who did not. We prospectively enrolled 257 subjects with a urinalysis and/or urine culture test ordered in the ED and asked them to watch our MSCC instructional app. After prospective enrollment was complete, we retrospectively matched each enrolled subject to an ED patient who did not watch the instructional app. Controls were matched to cases based on gender, type of urine specimen provided, ED visit date and shift. Urinalysis and urine culture contamination results were compared between the matched pairs using McNemar's test. The overall urine culture contamination rate of the 514 subjects was 38%. The majority of the matched pairs had a urinalysis (63%) or urinalysis plus urine culture (35%) test done. There were no significant differences in our urine contamination rates between the matched pairs overall or when stratified by gender, by prior knowledge of the clean catch process or by type of urine specimen. We did not see a lower contamination rate for patients who viewed our instructional app compared to patients who did not. It is possible that MSCC is not effective for decreasing urine specimen contamination. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Joint use of laboratory bioassays and field-collected plants to evaluate toxicity and contaminant bioaccumulation

    International Nuclear Information System (INIS)

    Long, S.P.; Byron, E.R.; Ohlendorf, H.M.

    1995-01-01

    Soil toxicity tests using lettuce (Latuca saliva) were conducted using soil samples collected as part of ecological risk assessments at two facilities in California. At some sites, terrestrial plants were collected in the field for chemical analysis. Ecological concerns focused on exposures to plants, phytophagous insects, and their secondary consumers, such as birds and small mammals. The toxicity tests were used to assess potential exposures to a variety of site-specific contaminants including organochlorine pesticides, PCBs, PAHs, petroleum hydrocarbons, heavy metals, and other inorganic substances. Site soils were combined with clean control soils to produce toxicity test soil dilutions containing 100%, 75%, 50%, 25%, and 0% site soils. Observations of seed germination and growth were made at day 0, 7, 14, 21 and 28. Toxicity test results were combined with soil chemical analytical results and physical characteristics to establish NOAELs and LOAELs. Bioaccumulation in the lettuce and field-collected plants was evaluated by comparing plant contaminant to soil contaminant concentrations. Allometric equations and sublethal toxicity data were used to predict potential effects on birds and small mammals. Whole-body contaminant concentrations in insects collected on some of the plants in the field were also considered in evaluating the potential for toxicity to insectivorous birds. The study indicated that contaminant uptake was occurring in the field-collected and bioassay plants but not the insects. Site factors in addition to soil contaminant concentration influenced the potential for plant toxicity and bioaccumulation

  13. Comparative analyses of contaminant levels in bottom feeding and predatory fish using the National Contaminant Biomonitoring Program data

    Energy Technology Data Exchange (ETDEWEB)

    Kidwell, J.M. [Clement International Corp., Fairfax, VA (United States); Phillips, L.J. [Versar Inc., Springfield, VA (United States); Birchard, G.F. [George Mason Univ., Fairfax, VA (United States)

    1995-06-01

    Both bottom feeding and predatory fish accumulate chemical contaminants found in water. Bottom feeders are readily exposed to the greater quantities of chlorinated hydrocarbons and metals that accumulate in sediments. Predators, on the other hand, may bioaccumulate organochlorine pesticides, PCBs, and metals from the surrounding water or from feeding on other fish, including bottom feeders, which may result in the biomagnification of these compounds in their tissues. This study used National Contaminant Biomonitoring Program data produced by the Fish and Wildlife Service to test the hypothesis that differences exist between bottom feeders and predators in tissue levels of organochlorine pesticides, PCBs, and metals. 7 refs., 2 tabs.

  14. Impact of inorganic contaminants on microalgae productivity and bioremediation potential.

    Science.gov (United States)

    Torres, Eric M; Hess, Derek; McNeil, Brian T; Guy, Tessa; Quinn, Jason C

    2017-05-01

    As underdeveloped nations continue to industrialize and world population continues to increase, the need for energy, natural resources, and goods will lead to ever increasing inorganic contaminants, such as heavy metals, in various waste streams that can have damaging effects on plant life, wildlife, and human health. This work is focused on the evaluation of the potential of Nannochloropsis salina to be integrated with contaminated water sources for the concurrent production of a biofuel feedstock while providing an environmental service through bioremediation. Individual contaminants (As, Cd, Cr, Co, Cu, Pb, Ni, Hg, Se, and Zn) at various concentrations ranging from a low concentration (1X) to higher concentrations (10X, and 40X) found in contaminated systems (mine tailings, wastewater treatment plants, produced water) were introduced into growth media. Biological growth experimentation was performed in triplicate at the various contaminant concentrations and at 3 different light intensities. Results show that baseline concentrations of each contaminant slightly decreased biomass growth to between 89% and 99% of the control with the exception of Ni which dramatically reduced growth. Increased contaminant concentrations resulted in progressively lower growth rates for all contaminants tested. Lipid analysis shows most baseline contaminant concentrations slightly decrease or have minimal effects on lipid content at all light levels. Trace contaminant analysis on the biomass showed Cd, Co, Cu, Pb, and Zn were sorbed by the microalgae with minimal contaminants remaining in the growth media illustrating the effectiveness of microalgae to bioremediate these contaminants when levels are sufficiently low to not detrimentally impact productivity. The microalgae biomass was less efficient at sorption of As, Cr, Ni, and Se. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Comparison of solid-phase bioassays and ecoscores to evaluate the toxicity of contaminated soils.

    Science.gov (United States)

    Lors, Christine; Ponge, Jean-François; Martínez Aldaya, Maite; Damidot, Denis

    2010-08-01

    Five bioassays (inhibition of lettuce germination and growth, earthworm mortality, inhibition of springtail population growth, avoidance by springtails) were compared, using four coke factory soils contaminated by PAHs and trace elements, before and after biotreatment. For each bioassay, several endpoints were combined in an 'ecoscore', a measure of test sensitivity. Ecoscores pooled over all tested bioassays revealed that most organisms were highly sensitive to the concentration of 3-ring PAHs. When four soils were combined, behavioural tests using the springtail Folsomia candida showed higher ecoscores, i.e. they were most sensitive to soil contamination. However, despite overall higher sensitivity of behavioural tests, which could be used for cheap and rapid assessment of soil toxicity, especially at low levels of contamination, some test endpoints were more sensitive than others, and this may differ from a soil to another, pointing to the need for a battery of bioassays when more itemized results are expected. Copyright 2010 Elsevier Ltd. All rights reserved.

  16. Effect of blood contamination on shear bond strength of orthodontic brackets and disinclusion buttons.

    Science.gov (United States)

    Sfondrini, Maria Francesca; Gatti, Sara; Scribante, Andrea

    2011-07-01

    Our aim was to assess the effect of blood contamination on the shear bonding strength and sites of failure of orthodontic brackets and bondable buttons. We randomly divided 160 bovine permanent mandibular incisors into 8 groups of 20 specimens each. Both orthodontic brackets (Step brackets, Leone, Sesto Fiorentino, Italy) and bondable buttons (Flat orthodontic buttons, Leone, Sesto Fiorentino, Italy) were tested on four different enamel surfaces: dry; contamination with blood before priming; after priming; and before and after priming. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bonding strength and the rate of adhesive failures were recorded. Data were analysed using the analysis of variance (ANOVA), Scheffè tests, and the chi-square test. Uncontaminated enamel surfaces showed the highest bonding strengths for both brackets and buttons. When they were contaminated with blood, orthodontic brackets had significantly lower shear strengths than bondable buttons (P=0.0001). There were significant differences in sites of failure among the groups for the various enamel surfaces (P=0.001). Contamination of enamel by blood during bonding lowers the strength of the bond, more so with orthodontic brackets than with bondable buttons. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. Phytoremediation and land management of radionuclide-contaminated areas

    Energy Technology Data Exchange (ETDEWEB)

    Vanek, T.; Valenova, S.; Soudek, P. [Czech Academy of Science, Inst. of Organic Chemistry and Biochemistry, (Czech Republic). Dept. of Plant Tissue Cultures

    2006-07-01

    A study was conducted to examine the feasibility of using radiophytoremediation for wastewater treatment, where the conditions of contaminants can be similar to hydroponic arrangement. Due to the fact that large doses of radiation can cause cellular damage, the remediation of radionuclides from the environment is important for human health. These high risk pollutants are introduced into the environment at uranium ore processing factories, nuclear power plants, and nuclear bomb testing sites. Following the Chernobyl accident in 1986, various studies were conducted to analyze the dynamic of {sup 137}Cs radionuclide in natural and semi-natural environments. The use of plants to clean up soils, sediments, surface and ground waters contaminated by radionuclides or toxic elements has been extensively tested. This study in particular, examined the uptake, translocation and distribution of {sup 137}Cs, {sup 90}Sr and {sup 125}I uptake from a radioactive hydroponic solution. It also examined the activity distribution within different plant tissues. The influence of K{sup +}, Ca{sup 2+} and NH{sub 4}{sup +} on {sup 137}Cs and {sup 90}Sr uptake and accumulation by sunflowers was also studied in order to evaluate the effects of these ions that are normally present in the soil. The study examined which plant species could grow in contaminated areas and accumulate large amounts of radionuclides which would be suitable for radiophytoremediation purposes. Approximately 44 plant species were tested in greenhouse experiments, field studies and constructed wetlands. It was concluded that for soil-cleaning purposes, the solubility of the contaminant and its mobility in soil is the main limiting factor along with the extent of root-zone of certain plant species. 38 refs., 5 tabs., 7 figs.

  18. Satellite Contamination and Materials Outgassing Knowledge base

    Science.gov (United States)

    Minor, Jody L.; Kauffman, William J. (Technical Monitor)

    2001-01-01

    Satellite contamination continues to be a design problem that engineers must take into account when developing new satellites. To help with this issue, NASA's Space Environments and Effects (SEE) Program funded the development of the Satellite Contamination and Materials Outgassing Knowledge base. This engineering tool brings together in one location information about the outgassing properties of aerospace materials based upon ground-testing data, the effects of outgassing that has been observed during flight and measurements of the contamination environment by on-orbit instruments. The knowledge base contains information using the ASTM Standard E- 1559 and also consolidates data from missions using quartz-crystal microbalances (QCM's). The data contained in the knowledge base was shared with NASA by government agencies and industry in the US and international space agencies as well. The term 'knowledgebase' was used because so much information and capability was brought together in one comprehensive engineering design tool. It is the SEE Program's intent to continually add additional material contamination data as it becomes available - creating a dynamic tool whose value to the user is ever increasing. The SEE Program firmly believes that NASA, and ultimately the entire contamination user community, will greatly benefit from this new engineering tool and highly encourages the community to not only use the tool but add data to it as well.

  19. Bioremediation of Petroleum Hydrocarbon Contaminated Sites

    Energy Technology Data Exchange (ETDEWEB)

    Fallgren, Paul

    2009-03-30

    Bioremediation has been widely applied in the restoration of petroleum hydrocarbon-contaminated. Parameters that may affect the rate and efficiency of biodegradation include temperature, moisture, salinity, nutrient availability, microbial species, and type and concentration of contaminants. Other factors can also affect the success of the bioremediation treatment of contaminants, such as climatic conditions, soil type, soil permeability, contaminant distribution and concentration, and drainage. Western Research Institute in conjunction with TechLink Environmental, Inc. and the U.S. Department of Energy conducted laboratory studies to evaluate major parameters that contribute to the bioremediation of petroleum-contaminated drill cuttings using land farming and to develop a biotreatment cell to expedite biodegradation of hydrocarbons. Physical characteristics such as soil texture, hydraulic conductivity, and water retention were determined for the petroleum hydrocarbon contaminated soil. Soil texture was determined to be loamy sand to sand, and high hydraulic conductivity and low water retention was observed. Temperature appeared to have the greatest influence on biodegradation rates where high temperatures (>50 C) favored biodegradation. High nitrogen content in the form of ammonium enhanced biodegradation as well did the presence of water near field water holding capacity. Urea was not a good source of nitrogen and has detrimental effects for bioremediation for this site soil. Artificial sea water had little effect on biodegradation rates, but biodegradation rates decreased after increasing the concentrations of salts. Biotreatment cell (biocell) tests demonstrated hydrocarbon biodegradation can be enhanced substantially when utilizing a leachate recirculation design where a 72% reduction of hydrocarbon concentration was observed with a 72-h period at a treatment temperature of 50 C. Overall, this study demonstrates the investigation of the effects of

  20. Influence of blood contamination during multimode adhesive application on the microtensile bond strength to dentin.

    Science.gov (United States)

    Kucukyilmaz, E; Celik, E U; Akcay, M; Yasa, B

    2017-12-01

    The present study evaluated the effects of blood contamination performed at different steps of bonding on the microtensile bond strength (μTBS) of multimode adhesives to dentin when using the self-etch approach. Seventy-five molars were randomly assigned to three adhesive groups comprising 25 specimens each: two multimode adhesives [Single Bond Universal (SBU) and All-Bond Universal (ABU)] and a conventional one-step self-etch adhesive [Clearfil S3 Bond Plus (CSBP)]. Each group was subdivided as follows: (1) uncontaminated (control): bonding application/light curing as a positive control; (2) contamination-1 (cont-1): bonding application/light curing/blood contamination/dry as a negative control; (3) contamination-2 (cont-2): bonding application/light curing/blood contamination/rinse/dry; (4) contamination-3 (cont-3): bonding application/blood contamination/dry/bonding re-application/light curing; and (5) contamination-4 (cont-4): bonding application/blood contamination/rinse/dry/bonding re-application/light curing. Dentin specimens were prepared for μTBS testing after the composite resin application. Data were analyzed with two-way ANOVA and post-hoc tests (α = 0.05). μTBS values were similar in cont-3 groups, and ABU/cont-4 and corresponding control groups, but were significantly lower in the other groups than in their control groups (P groups showed the lowest μTBS values (P blood contaminants and reapplying the adhesive may regain the dentin adhesion when contamination occurs before light curing. Alternatively, rinsing and drying contaminants followed by adhesive re-application may be effective depending on adhesive type.

  1. Phase I Hydrologic Data for the Groundwater Flow and Contaminant Transport Model of Corrective Action Unit 97: Yucca Flat/Climax Mine, Nevada Test Site, Nye County, Nevada, Rev. No.: 0

    Energy Technology Data Exchange (ETDEWEB)

    John McCord

    2006-06-01

    The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) initiated the Underground Test Area (UGTA) Project to assess and evaluate the effects of the underground nuclear weapons tests on groundwater beneath the Nevada Test Site (NTS) and vicinity. The framework for this evaluation is provided in Appendix VI, Revision No. 1 (December 7, 2000) of the Federal Facility Agreement and Consent Order (FFACO, 1996). Section 3.0 of Appendix VI ''Corrective Action Strategy'' of the FFACO describes the process that will be used to complete corrective actions specifically for the UGTA Project. The objective of the UGTA corrective action strategy is to define contaminant boundaries for each UGTA corrective action unit (CAU) where groundwater may have become contaminated from the underground nuclear weapons tests. The contaminant boundaries are determined based on modeling of groundwater flow and contaminant transport. A summary of the FFACO corrective action process and the UGTA corrective action strategy is provided in Section 1.5. The FFACO (1996) corrective action process for the Yucca Flat/Climax Mine CAU 97 was initiated with the Corrective Action Investigation Plan (CAIP) (DOE/NV, 2000a). The CAIP included a review of existing data on the CAU and proposed a set of data collection activities to collect additional characterization data. These recommendations were based on a value of information analysis (VOIA) (IT, 1999), which evaluated the value of different possible data collection activities, with respect to reduction in uncertainty of the contaminant boundary, through simplified transport modeling. The Yucca Flat/Climax Mine CAIP identifies a three-step model development process to evaluate the impact of underground nuclear testing on groundwater to determine a contaminant boundary (DOE/NV, 2000a). The three steps are as follows: (1) Data compilation and analysis that provides the necessary modeling

  2. A New Method for Processing Airborne Gamma Ray Spectrometry Data for Mapping Low Level Contaminations

    DEFF Research Database (Denmark)

    Aage, Helle Karina; Korsbech, Uffe C C; Bargholz, Kim

    1999-01-01

    A new technique for processing airborne gamma ray spectrometry data has been developed. It is based on the noise adjusted singular value decomposition method introduced by Hovgaard in 1997. The new technique opens for mapping of very low contamination levels. It is tested with data from Latvia...... where the remaining contamination from the 1986 Chernobyl accident together with fallout from the atmospheric nuclear weapon tests includes Cs-137 at levels often well below 1 kBq/m(2) equivalent surface contamination. The limiting factors for obtaining reliable results are radon in the air, spectrum...

  3. Corrective Action Decision Document for Corrective Action Unit 166: Storage Yards and Contaminated Materials, Nevada Test Site, Nevada with Errata Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Grant Evenson

    2007-03-01

    This Corrective Action Decision Document (CADD) has been prepared for Corrective Action Unit (CAU) 166, Storage Yards and Contaminated Materials, in accordance with the Federal Facility Agreement and Consent Order (1996). The corrective action sites (CASs) are located in Areas 2, 3, 5, and 18 of the Nevada Test Site, Nevada. Corrective Action Unit 166 is comprised of the following CASs: • 02-42-01, Cond. Release Storage Yd - North • 02-42-02, Cond. Release Storage Yd - South • 02-99-10, D-38 Storage Area • 03-42-01, Conditional Release Storage Yard • 05-19-02, Contaminated Soil and Drum • 18-01-01, Aboveground Storage Tank • 18-99-03, Wax Piles/Oil Stain The purpose of this CADD is to identify and provide the rationale for the recommendation of a corrective action alternative (CAA) for the seven CASs within CAU 166. Corrective action investigation (CAI) activities were performed from July 31, 2006, through February 28, 2007, as set forth in the CAU 166 Corrective Action Investigation Plan (NNSA/NSO, 2006).

  4. Earthworms and in vitro physiologically-based extraction tests: complementary tools for a holistic approach towards understanding risk at arsenic-contaminated sites.

    Science.gov (United States)

    Button, Mark; Watts, Michael J; Cave, Mark R; Harrington, Chris F; Jenkin, Gawen T

    2009-04-01

    The relationship of the total arsenic content of a soil and its bioaccumulation by earthworms (Lumbricus rubellus and Dendrodrilus rubidus) to the arsenic fraction bioaccessible to humans, measured using an in vitro physiologically-based extraction test (PBET), was investigated. Soil and earthworm samples were collected at 24 sites at the former arsenic mine at the Devon Great Consols (DGC) in southwest England (UK), along with an uncontaminated site in Nottingham, UK, for comparison. Analysis of soil and earthworm total arsenic via inductively coupled plasma mass spectrometry (ICP-MS) was performed following a mixed acid digestion. Arsenic concentrations in the soil were elevated (204-9,025 mg kg(-1)) at DGC. The arsenic bioaccumulation factor (BAF) for both earthworm species was found to correlate positively with the human bioaccessible fraction (HBF), although the correlation was only significant (P earthworms as complementary tools is explored as a holistic and multidisciplinary approach towards understanding risk at contaminated sites. Arsenic resistant earthworm species such as the L. rubellus populations at DGC are presented as a valuable tool for understanding risk at highly contaminated sites.

  5. Treatment of plutonium contaminations

    International Nuclear Information System (INIS)

    Lafuma, J.

    1983-01-01

    Three kinds of plutonium contaminations were considered: skin contamination; contaminated wounds; contamination by inhalation. The treatment of these contaminations was studied for insoluble (oxide and metal forms) and soluble plutonium (complexes). The use of DTPA and therapeutic problems encountered with stable plutonium complexes were analyzed. The new possibilities of internal decontamination using Puchel and LICAM were evaluated [fr

  6. Lifetime survivability of contaminated target-chamber optics

    International Nuclear Information System (INIS)

    Rainer, F.; Anderson, A.; Burnham, A.; Milam, D.; Turner, R.

    1996-11-01

    Target chambers used for Inertial Confinement Fusion (ICF) expose laser optics to a very hostile environment, not only from high-fluence laser irradiation but also x-ray irradiation and particulate debris from targets and chamber wall materials. Expendable debris shields provide the first line of defense to more costly optics upstream in the laser beam path to contaminants generated within the target chamber. However, the replacement of a large number of debris shields is also an expensive proposition so that extending their usable lifetime within the chamber is important. We have conducted tests to show that optics can both be cleaned and damaged by laser irradiation at 355 nm after being contaminated with potential chamber-wall materials such as B 4 C and Al 2 O 3 . Such optics can survive from one to hundreds of laser shots, depending on degree of contamination and laser fluence levels. Similarly, we have studied the survivability of optics that have been exposed to direct contamination from representative target materials irradiated in the target chamber. We have also studied the effects on optics that were not directly exposed to targets, yet received secondary exposure from the above directly-exposed samples

  7. Final report on contamination surveys at NPL

    International Nuclear Information System (INIS)

    Tuplin, T.A.

    1984-02-01

    The Environmental and Medical Sciences Division of Harwell was contracted to carry out detailed surveys of Building 154 at the National Physical Laboratory, Teddington. The survey used a variety of radiation detectors appropriate to the conditions found and also involved monitoring for the presence of beryllium, by means of smear (wiping) tests. The results from the beryllium survey showed that no areas exceeded accepted control limits. The results of the contamination survey indicated a few places where the derived limit was exceeded However, averaged over the accepted surface area (1000 cm 2 ), and noting that the contamination was fixed, the levels were considered to present no hazard to any worker in the area nor to anyone outside the building. The environmental radiation in Room 35, the most contaminated room, was one hundredth of a millirem per hour. In only one area (Room 26) was there a radiologically significant dose rate, caused by a sealed source of cobalt-60. The accessible dose rates close to the source were around 8 millirem per hour. However, the uranium contamination should be removed to be consistent with the principle that radiation exposure should be as low as reasonably achievable. (U.K.)

  8. The application of bioassays as indicators of petroleum-contaminated soil remediation.

    Science.gov (United States)

    Płaza, Grazyna; Nałecz-Jawecki, Grzegorz; Ulfig, Krzysztof; Brigmon, Robin L

    2005-04-01

    Bioremediation has proven successful in numerous applications to petroleum contaminated soils. However, questions remain as to the efficiency of bioremediation in lowering long-term soil toxicity. In the present study, the bioassays Spirotox, Microtox, Ostracodtoxkit F, umu-test with S-9 activation, and plant assays were applied, and compared to evaluate bioremediation processes in heavily petroleum contaminated soils. Six higher plant species (Secale cereale L., Lactuca sativa L., Zea mays L., Lepidium sativum L., Triticum vulgare L., Brassica oleracea L.) were used for bioassay tests based on seed germination and root elongation. The ecotoxicological analyses were made in DMSO/H2O and DCM/DMSO soil extracts. Soils were tested from two biopiles at the Czechowice oil refinery, Poland, that have been subjected to different bioremediation applications. In biopile 1 the active or engineered bioremediation process lasted four years, while biopile 2 was treated passively or non-engineered for eight months. The test species demonstrated varying sensitivity to soils from both biopiles. The effects on test organisms exposed to biopile 2 soils were several times higher compared to those in biopile 1 soils, which correlated with the soil contaminants concentration. Soil hydrocarbon concentrations indeed decreased an average of 81% in biopile 1, whereas in biopile 2 TPH/TPOC concentrations only decreased by 30% after eight months of bioremediation. The bioassays were presented to be sensitive indicators of soil quality and can be used to evaluate the quality of bioremediated soil. The study encourages the need to combine the bioassays with chemical monitoring for evaluation of the bioremediation effectiveness and assessing of the contaminated/remediated soils.

  9. Laboratory and field evaluation of the gas treatment approach for insitu remediation of chromate-contaminated soils

    International Nuclear Information System (INIS)

    Thornton, E.C.; Jackson, R.L.

    1994-04-01

    Laboratory scale soil treatment tests have been conducted as part of an effort to develop and implement an in situ chemical treatment approach to the remediation of chromate-contaminated soils through the use of reactive gases. These tests involved three different soil samples that were contaminated with Cr(VI) at the 200 ppM level. Treatment of the contaminated soils was performed by passing 100 ppM and 2000 ppM concentrations of hydrogen sulfide in nitrogen through soil columns until a S:Cr mole ratio of 10:1 was achieved. The treated soils were then leached with groundwater or deionized water and analyzed to assess the extent of chromium immobilization. Test results indicate >90% immobilization of chromium and demonstrate that the treatment process is irreversible. Ongoing developmental efforts are being directed towards the demonstration and evaluation of the gas treatment approach in a field test at a chromate-contaminated site. Major planned activities associated with this demonstration include laboratory testing of waste site soil samples, design of the treatment system and injection/extraction well network, geotechnical and geochemical characterization of the test site, and identification and resolution of regulatory and safety requirements

  10. Field studies to determine acceptable levels of contamination at former UK nuclear testing sites, Maralinga and Emu in Australia

    International Nuclear Information System (INIS)

    Davy, D.R.

    1988-01-01

    The Maralinga and Emu regions of South Australia were used between 1953 and 1961 for the UK nuclear weapon development program. Two types of trials were conducted - the major trials involved the detonation of fission weapons and the minor trials dealt with weapon design and operational safety. In 1986, as a result of the findings of the Royal Commission on Nuclear Testing in Australia, the UK and Australian governments agreed to set up a Technical Assessment Group (TAG) with one American, two Australian and two British members to review the Maralinga-Emu situation. TAG was to advise on a series of clean-up options and their associated costs and examine land-use options ranging from unrestricted use by the traditional Aboriginal land owners to options involving various degrees of administrative and physical control. In its interim report, presented in May 1986, TAG observed that the existing data base was inadequate and suggested a series of field and laboratory studies that would partly correct this situation. Six of these studies were concerned with redefining the existing levels of contamination and establishing acceptable levels of contamination for a range of land-use options. This paper discusses the rationale, organisational support, scope and experimental protocol adopted for each of the six studies

  11. Is there a risk of trace element contamination in herbal preparations? A test study on the lichen Cetraria islandica.

    Science.gov (United States)

    Giordani, Paolo; Minganti, Vincenzo; Brignole, Daniele; Malaspina, Paola; Cornara, Laura; Drava, Giuliana

    2017-08-01

    Lichens are a source of unique secondary metabolites, which have been proved to have many biological properties with possible pharmaceutical roles, including e.g. antioxidant, antimicrobial, antifungal or anti-inflammatory activities and to be worth of consideration for potential human use. However, lichens lack cuticolar tissues and are exposed to several atmospheric contaminants, including trace elements. This work aims at exploring the potential toxicity of herbal preparations derived by the lichen Cetraria islandica due to trace element contamination, testing whether different concentrations may be observed, depending on the origin of the raw material. Fourteen samples of C. islandica, as cut dried thalli occurring on the European market, have been bought from different providers. For each sample, the concentrations of As, Cd, Co, Cu, Fe, Mn, Ni, P, Pb, V and Zn were measured on comminuted herbal substance and on the corresponding decoction, using atomic emission spectrometry (ICP-OES). The elemental concentrations in decoctions were significantly lower than those measured in raw materials, dropping down to levels of negligible health concern. Differences observed in raw materials were not observed anymore in the corresponding decoctions. Also, the elemental transfer rate from dried lichen to decoction was extremely element-specific, ranging from 2% for Cu to 95% for Zn. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. A UVC Device for Intra-luminal Disinfection of Catheters: In Vitro Tests on Soft Polymer Tubes Contaminated with Pseudomonas aeruginosa, Staphylococcus aureus, Escherichia coli and Candida albicans

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja; Bjarnsholt, Thomas

    2011-01-01

    light is possible. In this paper we present dose-response results using a newly developed UVC disinfection device, which can be connected to a Luer catheter hub. The device was tested on soft polymer tubes contaminated with a pallet of microorganisms, including Candida albicans, Staphylococcus aureus...

  13. Effect of soil contaminant extraction method in determining toxicity using the Microtox(reg.) assay

    International Nuclear Information System (INIS)

    Harkey, G.A.; Young, T.M.

    2000-01-01

    This project examined the influence of different extraction methods on the measured toxicity of contaminated soils collected from manufactured gas plant (MGP) sites differing in soil composition and contaminant concentration. Aged soils from a number of MGP sites were extracted using a saline solution, supercritical fluid extraction (SFE), and Soxhlet extraction. Toxicity was assessed using two forms of Microtox tests: acute aqueous tests on saline and SFE soil extracts and solid-phase tests (SPTs) on soil particles. Microtox SPTs were performed on soils before and after SFE to determine resulting toxicity reduction. Three hypotheses were tested: (1) Toxicity of soil extracts is related to contaminant concentrations of the extracts, (2) measured toxicity significantly decreases with less vigorous methods of extraction, and (3) supercritical fluid extractability correlates with measured toxicity. The EC50s for SPTs performed before and after SFE were not different for some soils but were significantly greater after extraction for other soils tested. The most significant toxicity reductions were observed for soils exhibiting the highest toxicity in both preextraction SPTs and acute aqueous tests. Acute Microtox tests performed on SFE extracts showed significantly lower EC50s than those reported from saline-based extraction procedures. Toxicity of the soils measured by Microtox SPTs was strongly correlated with both SFE efficiency and measures of contaminant aging. Data from this project provide evidence of sequestration and reduced availability of polycyclic aromatic hydrocarbons (PAHs) from soils extracted via physiologically based procedures compared to vigorous physical extraction protocols

  14. Remediation of Oil-Contaminated Soil in Greenland

    DEFF Research Database (Denmark)

    Fritt-Rasmussen, Janne; Jensen, Pernille Erland

    2013-01-01

    This paper present the recent research conducted at the Arctic Technology Centre, where different solutions for remediation of excavated oil contaminated soil in Greenlandic towns were tested. In the first work, soil polluted by light oil was treated with two different nutrient sources (substrate...

  15. Shear bond strength of metallic brackets: influence of saliva contamination

    Directory of Open Access Journals (Sweden)

    Luciana Borges Retamoso

    2009-06-01

    Full Text Available OBJECTIVE: To evaluate the influence of saliva contamination on shear bond strength and the bond failure pattern of 3 adhesive systems (Transbond XT, AdheSE and Xeno III on orthodontic metallic brackets bonded to human enamel. MATERIAL AND METHODS: Seventy-two permanent human molars were cut longitudinally in a mesiodistal direction, producing seventy-two specimens randomly divided into six groups. Each system was tested under 2 different enamel conditions: no contamination and contaminated with saliva. In T, A and X groups, the adhesive systems were applied to the enamel surface in accordance with manufacturer's instructions. In TS, AS and XS groups, saliva was applied to enamel surface followed by adhesive system application. The samples were stored in distilled water at 37ºC for 24 h, and then tested for shear bond strength in a universal testing machine (Emic, DL 2000 running at a crosshead speed of 1 mm/min. After bond failure, the enamel surfaces were observed under an optical microscope at 40x magnification. RESULTS: The control and contaminated groups showed no significant difference in shear bond strength for the same adhesive system. However, shear bond strength of T group (17.03±4.91 was significantly higher than that of AS (8.58±1.73 and XS (10.39±4.06 groups (p<0.05. Regarding the bond failure pattern, TS group had significantly higher scores of no adhesive remaining on the tooth in the bonding area than other groups considering the adhesive remnant index (ARI used to evaluate the amount of adhesive left on the enamel. CONCLUSIONS: Saliva contamination showed little influence on the 24-h shear bond strength of orthodontic brackets.

  16. Avoidance test with Eisenia fetida as indicator for the habitat function of soils. Results of a laboratory comparison test

    Energy Technology Data Exchange (ETDEWEB)

    Hund-Rinke, K. [Fraunhofer Inst. for Molecular Biology and Applied Ecology, Schmallenberg (Germany); Achazi, R.; Warnecke, D. [Free Univ. of Berlin, Inst. for Biology, Berlin (Germany); Roembke, J. [ECT Oekotoxikologie GmbH, Floersheim (Germany)

    2003-07-01

    Intention, Goal, Scope, Background. The habitat function of soils is often assessed using the reproduction test with Eisenia fetida. As this test is rather labour-intensive, an alternative is needed which is less cost-intensive in terms of duration and workload, but gives reasonable results. The avoidance test with E. fetida is a suitable screening test meeting these criteria. However, before a novel test system can be generally recommended it has to be ensured that comparable results are acquired from different laboratories on the basis of the respective test guideline. Objective. The avoidance test with E. fetida was performed as laboratory comparison test. The results were compared with those of the earthworm acute and reproduction tests carried out with the same soils. Methods. The three tests were performed by three laboratories using eight contaminated soils and three control soils. The contaminated soils were mixed with the control soils to obtain different concentrations of the contamination. (orig.)

  17. INFLUENCE OF HEXAVALENT CHROMIUM INITIAL CONCENTRATION ON RETARDATION FACTOR AND CONTAMINANT VELOCITY IN A SOIL MEDIA

    Directory of Open Access Journals (Sweden)

    K. SHIVA PRASHANTH KUMAR

    2016-02-01

    Full Text Available Sources of soil and ground water contamination are many and include many folds of accidental spills and leaks of toxic and hazardous chemicals. Preparation of ground water contamination model needs good understanding of the behavior of contaminant transport through soil media for predicting the level of contamination of ground water in the near future at the intended site conditions. Sorption is a natural process; due to its presence, the contaminant can move slowly as compared to the ground water and hence the effects of sorption must be taken into consideration while predicting the travel time of the contaminant to reach the ground water sources. This paper discusses the results of column test studies carried out in the laboratory under controlled conditions about the spreading of contaminant (Hexavalent chromium, Cr (VI through the clay mixed red soil at two different initial concentrations (800 mg/L and 4200 mg/L. The variations of the contaminant flow velocity and retardation factor for two different initial concentrations of contaminant were brought out and discussed. The contaminant flow velocity drastically coming down for a relative concentration of 0 to 0.2 and beyond this range, the contaminant flow velocity value is decreasing in a slow rate for both the lower and higher initial contaminant concentrations tested. At the lower relative concentration, the higher retardation factor was observed and it may be due to slowly filling the available sorption sites in the soil column.

  18. CMI Remedy Selection for HE- and Barium-Contaminated Vadose Zone and Alluvium at LANL

    Science.gov (United States)

    Hickmott, D.; Reid, K.; Pietz, J.; Ware, D.

    2008-12-01

    A high explosives (HE) machining building outfall at Los Alamos National Laboratory's Technical Area 16 discharged millions of gallons of HE- and barium-contaminated water into the Canon de Valle watershed. The effluent contaminated surface soils, the alluvial aquifer, vadose zone waters, and deep-perched and regional groundwaters with HE and barium, frequently at levels greater than regulatory standards. Site characterization studies began in 1995 and included extensive monitoring of surface water, groundwater, soils, and subsurface solid media. Hydrogeologic and geophysical studies were conducted to help understand contaminant transport mechanisms and pathways. Results from the characterization studies were used to develop a site conceptual model. In 2000 the principal source area was removed. The ongoing Corrective Measure Study (CMS) and Corrective Measure Implementation (CMI) focus on residual vadose zone contamination and on the contaminated alluvial system. Regulators recently selected a CMI remedy that combined: 1) augmented source removal; 2) grouting of an HE- contaminated surge bed; 3) deployment of Stormwater Management System (SMS) stormfilters in contaminated springs; and 4) permeable reactive barriers (PRBs) in contaminated alluvium. The hydrogeologic conceptual model for the vadose zone and alluvial system as well as the status of the canyon as habitat for the Mexican Spotted Owl were key factors in selection of these minimal-environmental-impact remedies. The heterogeneous vadose zone, characterized by flow and contaminant transport in fractures and in surge beds, requires contaminant treatment at a point of discharge. The canyon PRB is being installed to capture water and contaminants prior to infiltration into the vadose zone. Pilot-scale testing of the SMS and lab-scale batch and column tests of a range of media suggest that granular activated carbon, zeolite, and gypsum may be effective media for removal of HE and/or barium from contaminated

  19. Vertical contamination in the unconfined groundwater at the Hanford Site, Washington

    International Nuclear Information System (INIS)

    Eddy, P.A.; Myers, D.A.; Raymond, J.R.

    1978-08-01

    Disposal to the ground at Hanford of large volumes of low- and intermediate-level wastes in the local unconfined groundwater flow system has raised concern about the movement and distribution of this waste. Previous work produced information on the horizontal movement of the waste, but little or no information exists on its vertical distribution within the unconfined groundwater flow system. In 1975 Phase I of a study was started to determine the vertical distribution of contaminants in three existing wells (699-28-40, 699-31-31, and 699-37-43). Because of negative results, only one well that produced positive results (699-31-31) was chosen for Phase II. Phase II consisted of tests conducted on this well by a testing company, with samples cross-checked by two different laboratories. Phase III was a cooperative study with Rockwell Hanford Operations, which included the installation, testing, and sampling of piezometers. The data were then analyzed using predictive codes and models in order to determine if vertical movement did occur. The present groundwater flow system shows some vertical contamination. However, concentrations are relatively higher near the surface of the flow system, indicating possible radial flow patterns from the groundwater mounds known to have developed under the chemical processing area disposal sites. Upward flow from deeper aquifers may be diluting the contaminant and masking a possible downward migration of contaminants

  20. Space Stirling Cryocooler Contamination Lessons Learned and Recommended Control Procedures

    Science.gov (United States)

    Glaister, D. S.; Price, K.; Gully, W.; Castles, S.; Reilly, J.

    The most important characteristic of a space cryocooler is its reliability over a lifetime typically in excess of 7 years. While design improvements have reduced the probability of mechanical failure, the risk of internal contamination is still significant and has not been addressed in a consistent approach across the industry. A significant fraction of the endurance test and flight units have experienced some performance degradation related to internal contamination. The purpose of this paper is to describe and assess the contamination issues inside long life, space cryocoolers and to recommend procedures to minimize the probability of encountering contamination related failures and degradation. The paper covers the sources of contamination, the degradation and failure mechanisms, the theoretical and observed cryocooler sensitivity, and the recommended prevention procedures and their impact. We begin with a discussion of the contamination sources, both artificial and intrinsic. Next, the degradation and failure mechanisms are discussed in an attempt to arrive at a contaminant susceptibility, from which we can derive a contamination budget for the machine. This theoretical sensitivity is then compared with the observed sensitivity to illustrate the conservative nature of the assumed scenarios. A number of lessons learned on Raytheon, Ball, Air Force Research Laboratory, and NASA GSFC programs are shared to convey the practical aspects of the contamination problem. Then, the materials and processes required to meet the proposed budget are outlined. An attempt is made to present a survey of processes across industry.

  1. Blast fracturing of bedrock to enhance recovery of contaminated groundwater

    International Nuclear Information System (INIS)

    Holzman, L.R.; Harvey, E.M.; McKee, R.C.E.; Katsabanis, T.

    1992-01-01

    Petroleum hydrocarbons releasd from a pipeline at a site in southern Ontario had contaminated a fractured dolostone bedrock aquifer. To remediate the site, contaminated groundwater was pumped from the downgradient edge of the hydrocarbon plume and injected into an upgradient area after treatment. Contaminant flow pathways in the fractured bedrock aquifer were found to be complex and erratic. It was anticipated that contaminated groundwater could escape the influence of a line of closely spaced recovery wells. In order to capture the migrating contaminants effectively, improve communication between recovery wells, and optimize pumping efficiencies, a rubble zone was created by drilling and blasting the rock. Using 140 blastholes, the bedrock was fractured to a depth of 4 m over a distance of 200 m. Similarly, an additional 80 blastholes were used to blast fracture 100 m of bedrock to a depth of 4 m in the recharge area to enhance injection of treated water to the aquifer. Various blasthole spacings and explosive loadings and patterns were tested to fracture the rock effectively while minimizing the impact on the nearby pipeline and neighboring residences. Vibrations were carefully monitored using several seismographs. Pump tests conducted before and after the blast indicated the hydraulic connection between the naturally occurring fractures had greatly improved. Monitoring conducted after startup of the pump-treat-and-inject system has confirmed the fracturing provides effective capture and injection of the groundwater. 3 refs., 3 figs., 1 tab

  2. Sub-micrometer scale minor element mapping in interplanetary dust particles: a test for stratospheric contamination

    International Nuclear Information System (INIS)

    Flynn, G.J.; Keller, L.P.; Sutton, S.R.

    2006-01-01

    We mapped the spatial distribution of minor elements including K, Mn, and Zn in 3 IDPs and found no evidence for the surface coatings (rims) of these elements that would be expected if the enrichments previously reported were due to contamination. Combined X-ray microprobe (XRM), energy dispersive x-ray fluorescence using a Transmission Electron Microscope (TEM), and electron microprobe measurements have determined that the average bulk chemical composition of the interplanetary dust particles (IDPs) collected from the Earth's stratosphere is enriched relative to the CI meteorite composition by a factor of 2 to 4 for carbon and for the moderately volatile elements Na, K, P, Mn, Cu, Zn, Ga, Ge, and Se, and enriched to ∼30 times CI for Br. However, Jessberger et al., who have reported similar bulk enrichments using Proton Induced X-ray Emission (PIXE), attribute the enrichments to contamination by meteor-derived atmospheric aerosols during the several weeks these IDPs reside in the Earth's atmosphere prior to collection. Using scanning Auger spectroscopy, a very sensitive surface analysis technique, Mackinnon and Mogk have observed S contamination on the surface of IDPs, presumably due to the accretion of sulfate aerosols during stratospheric residence. But the S-rich layer they detected was so thin (∼100 angstroms thick) that the total amount of S on the surface was too small to significantly perturb the bulk S-content of a chondritic IDP. Stephan et al. provide support for the contamination hypothesis by reporting the enrichment of Br on the edges of the IDPs using Time-of-Flight Secondary-Ion Mass-Spectrometry (TOF-SIMS), but TOF-SIMS is notorious for producing false edge-effects, particularly on irregularly-shaped samples like IDPs. Sutton et al. mapped the spatial distribution of Fe, Ni, Zn, Br, and Sr, at the ∼2 (micro)m scale, in four IDPs using element-specific x-ray fluorescence (XRF) computed microtomography. They found the moderately volatile

  3. Corrective Action Investigation Plan for Corrective Action Unit 190: Contaminated Waste Sites Nevada Test Site, Nevada, Rev. No.: 0

    International Nuclear Information System (INIS)

    Wickline, Alfred

    2006-01-01

    Corrective Action Unit (CAU) 190 is located in Areas 11 and 14 of the Nevada Test Site, which is 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 190 is comprised of the four Corrective Action Sites (CASs) listed below: (1) 11-02-01, Underground Centrifuge; (2) 11-02-02, Drain Lines and Outfall; (3) 11-59-01, Tweezer Facility Septic System; and (4) 14-23-01, LTU-6 Test Area. These sites are being investigated because existing information is insufficient on the nature and extent of potential contamination to evaluate and recommend corrective action alternatives. Additional information will be obtained before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS by conducting a corrective action investigation (CAI). The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on August 24, 2006, by representatives of the Nevada Division of Environmental Protection; U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture, and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 190. The scope of the CAU 190 CAI includes the following activities: (1) Move surface debris and/or materials, as needed, to facilitate sampling; (2) Conduct radiological and geophysical surveys; (3) Perform field screening; (4) Collect and submit environmental samples for laboratory analysis to determine whether contaminants of concern (COCs) are present; (5) If COCs are present, collect additional step-out samples to define the lateral and vertical extent of the contamination; (6) Collect samples of source material, if present

  4. Envelope Protection for In-Flight Ice Contamination

    Science.gov (United States)

    Gingras, David R.; Barnhart, Billy P.; Ranaudo, Richard J.; Ratvasky, Thomas P.; Morelli, Eugene A.

    2010-01-01

    Fatal loss-of-control (LOC) accidents have been directly related to in-flight airframe icing. The prototype system presented in this paper directly addresses the need for real-time onboard envelope protection in icing conditions. The combinations of a-priori information and realtime aerodynamic estimations are shown to provide sufficient input for determining safe limits of the flight envelope during in-flight icing encounters. The Icing Contamination Envelope Protection (ICEPro) system has been designed and implemented to identify degradations in airplane performance and flying qualities resulting from ice contamination and provide safe flight-envelope cues to the pilot. Components of ICEPro are described and results from preliminary tests are presented.

  5. Toxicological assessment of aquatic ecosystems: application to watercraft contaminants in shallow water environments

    Science.gov (United States)

    Winger, P.V.; Kemmish, Michael J.

    2002-01-01

    Recreational boating and personal watercraft use have the potential to adversely impact shallow water systems through contaminant release and physical disturbance of bottom sediments. These nearshore areas are often already degraded by surface runoff, municipal and industrial effluents, and other anthropogenic activities. For proper management, information is needed on the level of contamination and environmental quality of these systems. A number of field and laboratory procedures can be used to provide this much needed information. Contaminants, such as metals, pesticides, polychlorinated biphenyls and polycyclic aromatic hydrocarbons, entering aquatic environments generally attach to particulate matter that eventually settles and becomes incorporated into the bottom sediments. Because bottom sediments serve as a sink and as a source for contaminants, environmental assessments generally focus on this matrix. While contaminant residues in sediments and sediment pore waters can reflect environmental quality, characteristics of sediment (redox potential, sediment/pore-water chemistry, acid volatile sulfides, percent organic matter, and sediment particle size) influence their bioavailability and make interpretation of environmental significance difficult. Comparisons of contaminant concentrations in pore water (interstitial water) and sediment with water quality criteria and sediment quality guidelines, respectively, can provide insight into potential biological effects. Laboratory bioaccumulation studies and residue concentrations in resident or caged biota also yield information on potential biological impacts. The usefulness of these measurements may increase as data are developed relating in-situ concentrations, tissue residue levels, and biological responses. Exposure of test organisms in situ or to field-collected sediment and pore water are additional procedures that can be used to assess the biological effects of contaminants. A battery of tests using multi

  6. Cleanup of contaminated areas; La bonifica di aree contaminate

    Energy Technology Data Exchange (ETDEWEB)

    Beone, G; Carbone, A I; Zagaroli, M [ENEA - Dipartimento Protezione Ambientale e Salute dell' Uomo, Centro Ricerche Energia, Casaccia (Italy)

    1989-01-15

    The paper deals with the problem of contaminated areas cleanup, in order to eliminate every possible damage for man safety and environment and to site recovery for some utilization, The first step of cleanup operation is site characterization, that is followed by a pianificazion activity for a better definition of staff qualification, technology to be used, protection and prevention instruments for the risks due to contaminants handling. The second section describes the different remedial technologies for contaminated sites. Remedial technologies may be divided into on-site/off-site and in-situ treatments, according to whether materials (waste, soil, water) are moved to another location or not, respectively. Finally, it is outlined that contaminated areas cleanup is a typical multidisciplinary activity because very different competences are required. (author)

  7. Current Measures on Radioactive Contamination in Japan: A Policy Situation Analysis.

    Science.gov (United States)

    Gilmour, Stuart; Miyagawa, Shoji; Kasuga, Fumiko; Shibuya, Kenji

    2016-01-01

    radioactive contamination. Monitoring of radioactive materials in food products in the prefectures has been mainly conducted before shipment to restrict the distribution of radio-contaminated foods. Between March 2011 and March 2012, 133,832 tests of non-commercial and commercial products were conducted, and 1,204 tests (0.9%) were found to violate the provisional standards. Since April 2012, 278,275 tests were conducted, and 2,372 tests (0.9%) were found to violate the revised standards. MHLW assessment of representative market baskets of foodstuffs at 15 locations throughout Japan between February and March 2014 found very low estimated dietary intake of radioactive cesium (0.0007-0.019 mSv/year), as did assessments of the contents of an average day's food. Monitoring of fisheries products in coastal areas affected by the nuclear accident found very limited and declining radio-contamination of live fish outside of Fukushima prefecture. Fisheries monitoring is of limited geographical scope and covers only certain fishes. Area-specific bans on production and distribution have been effective in preventing radioactive contamination in the Japanese food market. Currently there is no major concern about radioactive cesium concentrations in retail foodstuffs in Japan, and very low levels of contamination at the production and wholesale stage. However, because the residue limits and food safety policies were revised on an ad hoc, emergency basis after the nuclear accident, the monitoring procedure needs to be reviewed based on objective and scientifically rational criteria. A transparent and objective scientific framework is needed for prioritizing foodstuffs for inspection and revising Prefecture-specific restrictions. Monitoring of fishes and other seafood products in the wild should be regularized and the information made more publicly accessible, and monitoring activities expanded to identify foodstuffs that are no longer a food safety risk. Consultation with producers and

  8. 40 CFR 141.51 - Maximum contaminant level goals for inorganic contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant level goals for inorganic contaminants. 141.51 Section 141.51 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Maximum Contaminant Level...

  9. 40 CFR 141.50 - Maximum contaminant level goals for organic contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant level goals for organic contaminants. 141.50 Section 141.50 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Maximum Contaminant Level...

  10. 40 CFR 141.52 - Maximum contaminant level goals for microbiological contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant level goals for microbiological contaminants. 141.52 Section 141.52 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) NATIONAL PRIMARY DRINKING WATER REGULATIONS Maximum Contaminant Level...

  11. Contamination Detection and Mitigation Strategies for Unsymmetric Dimethylhydrazine/Nitrogen Tetroxide Non-Combustion Product Residues

    Science.gov (United States)

    Greene, Benjamin; Buchanan, Vanessa D.; Baker, David L.

    2006-01-01

    Dimethylamine and nitrite, which are non-combustion reaction products of unsymmetrical dimethylhydrazine (UDMH) and nitrogen tetroxide (NTO) propellants, can contaminate spacesuits during extra-vehicular activity (EVA) operations. They can react with water in the International Space Station (ISS) airlock to form N-nitrosodimethylamine (NDMA), a carcinogen. Detection methods for assessing nitrite and dimethylamine contamination were investigated. The methods are based on color-forming reactions in which intensity of color is proportional to concentration. A concept color detection kit using a commercially available presumptive field test for methamphetamine coupled with nitrite test strips was developed and used to detect dimethylamine and nitrite. Contamination mitigation strategies were also developed.

  12. Remediation of TCE-contaminated groundwater using nanocatalyst and bacteria.

    Science.gov (United States)

    Kang, Ser Ku; Seo, Hyunhee; Sun, Eunyoung; Kim, Inseon; Roh, Yul

    2011-08-01

    The objective of this study was to develop and evaluate the remediation of trichloroethene (TCE)-contaminated groundwater using both a nanocatalyst (bio-Zn-magnetite) and bacterium (similar to Clostridium quinii) in anoxic environments. Of the 7 nanocatalysts tested, bio-Zn-magnetite showed the highest TCE dechlorination efficiency, with an average of ca. 90% within 8 days in a batch experiment. The column tests confirmed that the application of bio-Zn-magnetite in combination with the bacterium achieved high degradation efficiency (ca. 90%) of TCE within 5 days compared to the nanocatalyst only, which degraded only 30% of the TCE. These results suggest that the application of a nanocatalyst and the bacterium have potential for the remediation of TCE-contaminated groundwater in subsurface environments.

  13. Experimental bifurcation analysis—Continuation for noise-contaminated zero problems

    DEFF Research Database (Denmark)

    Schilder, Frank; Bureau, Emil; Santos, Ilmar Ferreira

    2015-01-01

    Noise contaminated zero problems involve functions that cannot be evaluated directly, but only indirectly via observations. In addition, such observations are affected by a non-deterministic observation error (noise). We investigate the application of numerical bifurcation analysis for studying...... the solution set of such noise contaminated zero problems, which is highly relevant in the context of equation-free analysis (coarse grained analysis) and bifurcation analysis in experiments, and develop specialized algorithms to address challenges that arise due to the presence of noise. As a working example......, we demonstrate and test our algorithms on a mechanical nonlinear oscillator experiment using control based continuation, which we used as a main application and test case for development of the Coco compatible Matlab toolbox Continex that implements our algorithms....

  14. Harvesting contaminants from liquid

    Science.gov (United States)

    Simpson, John T.; Hunter, Scott R.

    2016-05-31

    Disclosed are examples of apparatuses for evaporative purification of a contaminated liquid. In each example, there is a vessel for storing the contaminated fluid. The vessel includes a surface coated with a layer of superhydrophobic material and the surface is at least partially in contact with the contaminated liquid. The contaminants do not adhere to the surface as the purified liquid evaporates, thus allowing the contaminants to be harvested.

  15. Effect of blood contamination with 1-step self-etching adhesives on microtensile bond strength to dentin.

    Science.gov (United States)

    Yoo, H M; Pereira, P N R

    2006-01-01

    This study evaluated the effect of blood contamination and decontamination methods on the microtensile bond strength of 1-step self-etching adhesive systems to dentin contaminated after adhesive application and light curing. Three commercially available "all-in-one" adhesives (One Up Bond F, Xeno III and Adper Prompt L-Pop) and 1 resin composite (Clearfil AP-X) were used. Third molars that had been stored in distilled water with 0.5% thymol at 4 degrees C were ground with #600 SiC paper under running water to produce a standardized smear layer. The specimens were randomly divided into groups according to the 3 adhesive systems. The adhesive systems were used under 3 conditions: no contamination, which was the control (C); contamination of the light-cured adhesive surface with blood and reapplication of adhesive (Contamination 1) and contamination of the light-cured adhesive surface with blood, then washing, drying and reapplication of the adhesive (Contamination 2). Following light curing of the adhesive, the resin composite was placed in 3 increments up to a 5-mm-thick layer on the bonded surface. All specimens were stored in distilled water at 37 degrees C for 24 hours. The microtensile bond strength was measured using a universal testing machine (EZ test), and data were analyzed by 1-way ANOVA followed by the Duncan test to make comparisons among the groups (p=0.05). After debonding, 5 specimens were selected from each group and examined in a scanning electron microscope to evaluate the modes of fracture. For all adhesives, contamination groups showed lower bond strength than the control (p0.05). For Xeno III and Adper Prompt L-Pop, contamination group #2 showed the lowest bond strength among the groups (pcontamination group #2 showed higher bond strength than contamination group #1 but showed no statistical significance between them (p>0.05).

  16. Outgassing tests on iras solar panel samples

    Science.gov (United States)

    Premat, G.; Zwaal, A.; Pennings, N. H.

    1980-01-01

    Several outgassing tests were carried out on representative solar panel samples in order to determine the extent of contamination that could be expected from this source. The materials for the construction of the solar panels were selected as a result of contamination obtained in micro volatile condensable materials tests.

  17. 40 CFR 141.63 - Maximum contaminant levels (MCLs) for microbiological contaminants.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 22 2010-07-01 2010-07-01 false Maximum contaminant levels (MCLs) for microbiological contaminants. 141.63 Section 141.63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Water Regulations: Maximum Contaminant Levels and Maximum Residual Disinfectant Levels § 141.63 Maximum...

  18. Factors affecting the distribution of hydrocarbon contaminants and hydrogeochemical parameters in a shallow sand aquifer

    Science.gov (United States)

    Lee, Jin-Yong; Cheon, Jeong-Yong; Lee, Kang-Kun; Lee, Seok-Young; Lee, Min-Hyo

    2001-07-01

    The distributions of hydrocarbon contaminants and hydrogeochemical parameters were investigated in a shallow sand aquifer highly contaminated with petroleum hydrocarbons leaked from solvent storage tanks. For these purposes, a variety of field investigations and studies were performed, which included installation of over 100 groundwater monitoring wells and piezometers at various depths, soil logging and analyses during well and piezometer installation, chemical analysis of groundwater, pump tests, and slug tests. Continuous water level monitoring at three selected wells using automatic data-logger and manual measuring at other wells were also conducted. Based on analyses of the various investigations and tests, a number of factors were identified to explain the distribution of the hydrocarbon contaminants and hydrogeochemical parameters. These factors include indigenous biodegradation, hydrostratigraphy, preliminary pump-and-treat remedy, recharge by rainfall, and subsequent water level fluctuation. The permeable sandy layer, in which the mean water table elevation is maintained, provided a dominant pathway for contaminant transport. The preliminary pump-and-treat action accelerated the movement of the hydrocarbon contaminants and affected the redox evolution pattern. Seasonal recharge by rain, together with indigenous biodegradation, played an important role in the natural attenuation of the petroleum hydrocarbons via mixing/dilution and biodegradation. The water level fluctuations redistributed the hydrocarbon contaminants by partitioning them into the soil and groundwater. The identified factors are not independent but closely inter-correlated.

  19. Insulator Contamination Forecasting Based on Fractal Analysis of Leakage Current

    Directory of Open Access Journals (Sweden)

    Bing Luo

    2012-07-01

    Full Text Available In this paper, an artificial pollution test is carried out to study the leakage current of porcelain insulators. Fractal theory is adopted to extract the characteristics hidden in leakage current waveforms. Fractal dimensions of the leakage current for the security, forecast and danger zones are analyzed under four types of degrees of contamination. The mean value and the standard deviation of the fractal dimension in the forecast zone are calculated to characterize the differences. The analysis reveals large differences in the fractal dimension of leakage current under different contamination discharge stages and degrees. The experimental and calculation results suggest that the fractal dimension of a leakage current waveform can be used as a new indicator of the discharge process and contamination degree of insulators. The results provide new methods and valid indicators for forecasting contamination flashovers.

  20. Lead Testing in Soil Contaminated with Pesticides and Reducing its Effects by the Activity of Activated Charcoal

    Directory of Open Access Journals (Sweden)

    Devesh Chand Thakur

    2014-07-01

    Full Text Available Background: Lead poisoning is classically defined as exposure to high levels of lead typically associated with severe health effects, but being a heavy metal which is potentially toxic, if present at even minor concentrations, it is of great concern to environmentalists and medical professionals alike. Activated charcoal has been known to adsorb heavy metals and thus, was used in this study as well. Aim: The main aim of this study was to decrease the lead content of agricultural soil which is attributed to the use of pesticides containing lead by using activated charcoal. Material and Methods: The lead contamination in agricultural soil and plant dry mass samples which increases due to the effect of pesticides was detected by using Field Portable X-Ray Fluroscence (FP-XRF spectrophotometer. Soil was taken in plastic trays and the plants were grown and watered daily. The collected ground water was also tested. For the estimation of lead in water samples, Graphite Furnace Atomic Absorption Spectroscopy (GFAAS was employed. Results: This study suggested the remediation of soil lead content by using activated charcoal. The study also revealed that activated charcoal not only adsorbs lead but also inhibits the accumulation of lead in ground water. Conclusion: This study promotes a cost effective process to treat agricultural lands polluted with leaded pesticides. Water purifiers, refrigerator etc. contain varying amounts of activated charcoal, after usage of these appliances it can be recycled and used as a source of activated charcoal. This can be applied in pesticide contaminated fields either in the form of slurry or by spraying.

  1. Ecotoxicological evaluation of diesel-contaminated soil before and after a bioremediation process.

    Science.gov (United States)

    Molina-Barahona, L; Vega-Loyo, L; Guerrero, M; Ramírez, S; Romero, I; Vega-Jarquín, C; Albores, A

    2005-02-01

    Evaluation of contaminated sites is usually performed by chemical analysis of pollutants in soil. This is not enough either to evaluate the environmental risk of contaminated soil nor to evaluate the efficiency of soil cleanup techniques. Information on the bioavailability of complex mixtures of xenobiotics and degradation products cannot be totally provided by chemical analytical data, but results from bioassays can integrate the effects of pollutants in complex mixtures. In the preservation of human health and environment quality, it is important to assess the ecotoxicological effects of contaminated soils to obtain a better evaluation of the healthiness of this system. The monitoring of a diesel-contaminated soil and the evaluation of a bioremediation technique conducted on a microcosm scale were performed by a battery of ecotoxicological tests including phytotoxicity, Daphnia magna, and nematode assays. In this study we biostimulated the native microflora of soil contaminated with diesel by adding nutrients and crop residue (corn straw) as a bulking agent and as a source of microorganisms and nutrients; in addition, moisture was adjusted to enhance diesel removal. The bioremediation process efficiency was evaluated directly by an innovative, simple phytotoxicity test system and the diesel extracts by Daphnia magna and nematode assays. Contaminated soil samples were revealed to have toxic effects on seed germination, seedling growth, and Daphnia survival. After biostimulation, the diesel concentration was reduced by 50.6%, and the soil samples showed a significant reduction in phytotoxicity (9%-15%) and Daphnia assays (3-fold), confirming the effectiveness of the bioremediation process. Results from our microcosm study suggest that in addition to the evaluation of the bioremediation processes efficiency, toxicity testing is different with organisms representative of diverse phylogenic levels. The integration of analytical, toxicological and bioremediation data

  2. Monitoring of tritium-contaminated surfaces, including skin

    International Nuclear Information System (INIS)

    Surette, R.A.; Wood, M.J.

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation's PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55's susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs

  3. Effects of chemical contamination on HDPE - thermo-mechanical and characterisation properties

    International Nuclear Information System (INIS)

    Ashraf, G.

    2002-01-01

    Studying the effects of chemical contamination on HDPE is an important precursor in recycling of plastic packaging and polymer reprocessing. This research involves and discusses the results of an in-depth investigation into the effects of chemically contaminating, using various acids, commercial grade high density polyethylene (HDPE) used commonly in packaging applications. An extensive formulation study was conducted and it became obvious that in some cases degradation had occurred to HDPE when chemically contaminated with particular functional group types. The functional groups in contaminated HDPE were successfully identified. A variety of analytical techniques such as Fourier transform Infra-red spectroscopy, X-ray Florescence, x-ray photo electron spectroscopy could identify compounds such as HCl acid, HNO/sub 3/ acid and other related contaminants. Some chemical additives had effects on the mechanical and thermal properties when added in the most appropriate concentration. The results have shown lower tensile modulus and strength tensile elongation, lower modular weight, melt flow index and crystallinity. The amount of contaminant concentration, the type of chemical functional groups used and the type of test selected to affect degradation are important factors in proving the effects of chemical contamination on HDPE in the melt state. (author)

  4. Present situation of radioactive contamination in and around the former Soviet Union's Semipalatinsk nuclear test site

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, M. [Kanazawa Univ., Low Level Radioactivity Laboratory, Ishikawa (Japan); Hoshi, M.; Takada, J. [Hiroshima Univ., Research Institute for Radiation Biology and Medicine, Hiroshima (Japan); Tsukatani, T. [Kyoto Univ., Kyoto Institute of Economic Research, Kyoto (Japan); Oikawa, S. [Japan Chemical Analytical Center, Inage, Chiba (Japan); Yoshikawa, I.; Takatsuji, T. [Nagasaki Univ., Faculty of Environmental Studies, Nagasaki (Japan); Sekerbaev, A. Kh.; Gusev, B.I. [Kazakh Scientific Research Institute for Radiation Medicine and Ecology, Semipalatinsk (Kazakhstan)

    2001-03-01

    Field missions were sent to the Semipalatinsk regions to investigate the present radioecological situation as a result of the radioactive fallout from nuclear test explosions carried out at the former Soviet Union's Semipalatinsk nuclear test site (SNTS). For this purpose, surface and core soil samples were collected at more than 60 sites, including several settlements such as Dolon, Chagan and Sarzhal, within and outside the SNTS territory. The radioactivities of long-lived radionuclides, {sup 137}Cs, {sup 238}Pu and {sup 239,240}Pu, and the atomic ratio of {sup 240}Pu/{sup 239}Pu were determined in combination with non-destructive g-ray spectrometric method and radiochemical separation followed by a-particle spectrometric and/or ICP-MS methods. The results showed a distinction of {sup 137}Cs and {sup 239,240}Pu inventories in soil depending on a sampling sites. Although {sup 137}Cs was within typical environmental levels except for the area near the first nuclear test site and Balapan, {sup 239,240}Pu was at elevated levels in all areas we visited. This high Pu contamination was recognized to be due to the weapons-grade Pu from the SNTS by the measurement of {sup 240}Pu/{sup 239P}u atomic ratio in soil samples. (author)

  5. Corrective Action Plan for Corrective Action Unit 168: Area 25 and 26 Contaminated Materials and Waste Dumps, Nevada Test Site, Nevada, REV 1

    International Nuclear Information System (INIS)

    NSTec Environmental Restoration

    2007-01-01

    Corrective Action Unit (CAU) 168 is identified in the Federal Facility Agreement and Consent Order of 1996 as Area 25 and 26 Contaminated Materials and Waste Dumps. CAU 168 consists of twelve Corrective Action Sites (CASs) in Areas 25 and 26 of the Nevada Test Site, which is approximately 105 kilometers (65 miles) northwest of Las Vegas, Nevada. The CASs contain surface and subsurface debris, impacted soil, and contaminated materials. Site characterization activities were conducted in 2002, and the results are presented in the Corrective Action Decision Document (CADD) for CAU 168 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2006). Site characterization results indicated that soil at several sites exceeded the clean-up criteria for total petroleum hydrocarbons (TPH), polychlorinated biphenyls (PCBs), and radionuclides. The Nevada Division of Environmental Protection approved the proposed corrective actions specified in the CADD (NNSA/NSO, 2006). The approved corrective actions include no further action, clean closure, and closure in place with administrative controls

  6. Contaminant transport at a waste residue deposit

    DEFF Research Database (Denmark)

    Engesgaard, Peter Knudegaard; Traberg, Rikke

    1996-01-01

    Contaminant transport in an aquifer at an incinerator waste residue deposit in Denmark is simulated. A two-dimensional, geochemical transport code is developed for this purpose and tested by comparison to results from another code, The code is applied to a column experiment and to the field site...

  7. Effect of gold photocathode contamination on a flat spectral response X-ray diode

    Science.gov (United States)

    Wang, Kun-lun; Zhang, Si-qun; Zhou, Shao-tong; Huang, Xian-bin; Ren, Xiao-dong; Dan, Jia-kun; Xu, Qiang

    2018-03-01

    A detector with an approximately flat spectral response is important for diagnosing intense thermal X-ray flux. A flat-spectral-response X-ray diode (FSR-XRD) utilizes a gold photocathode X-ray diode and a specially configured gold filter to give rise to a nearly flat spectral response in the photon energy range of 100-4000 eV. It has been observed that the spectral responses of several FSR-XRDs changed after a few shots of z-pinch experiments on the Primary Test Stand facility. This paper presents an analysis of the changes by fitting the spectral responses of the gold photocathodes using a model with a free parameter which characterizes the thickness of the contamination. The spectral responses of FSR-XRDs were calibrated with synchrotron radiation, and several cleaning methods were tested with the calibration. Considering the results of model and cleaning, it may be anticipated that contamination was the major reason of the response changing. Contamination worsened the flatness of the spectral response of the FSR-XRD and decreased the averaged response, hence it is important to avoid contamination. Current results indicate a requirement of further study of the contamination.

  8. Radiopharmacy contamination in nuclear medicine - a survey report

    International Nuclear Information System (INIS)

    Ghai, Anchal; Mardi, Somnath; Kumar, Pradeep; Sarika; Mittal, B.R.; Singh, B.

    2011-01-01

    To conduct the radiation survey of the category IV Nuclear Medicine department and to further measure and compare the level of loose contamination in areas with high levels of exposure at two different time points (morning and evening) using wipe test

  9. Ecotoxicological and analytical assessment of hydrocarbon-contaminated soils and application to ecological risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Saterbak, A.; Toy, R.J.; Wong, D.C.L.; McMain, B.J.; Williams, M.P.; Dorn, P.B.; Brzuzy, L.P.; Chai, E.Y.; Salanitro, J.P.

    1999-07-01

    Ecotoxicological assessments of contaminated soil aim to understand the effect of introduced chemicals on the soil flora and fauna. Ecotoxicity test methods were developed and conducted on hydrocarbon-contaminated soils and on adjacent uncontaminated control soils from eight field locations. Tests included 7-d, 14-d, and chronic survival tests and reproduction assays for the earthworm (Eisenia fetida) and seed germination, root length, and plant growth assays for corn, lettuce, mustard, and wheat. Species-specific responses were observed with no-observed effect concentrations (NOECs) ranging from <1 to 100% contaminated soil. The 14-d earthworm survival NOEC was equal to or greater than the reproduction NOEC values for numbers of cocoons and juveniles, which were similar to one another. Cocoon and juvenile production varied among the control soils. Germination and root length NOECs for mustard and lettuce were less than NOECs for corn and wheat. Root length NOECs were similar to or less than seed germination NOECs. Statistically significant correlations for earthworm survival and seed germination as a function of hydrocarbon measurements were found. The 14-d earthworm survival and the seed germination tests are recommended for use in the context of a risk-based framework for the ecological assessment of contaminated sites.

  10. Laboratory-scale bioremediation of oil-contaminated soil of Kuwait with soil amendment materials.

    Science.gov (United States)

    Cho, B H; Chino, H; Tsuji, H; Kunito, T; Nagaoka, K; Otsuka, S; Yamashita, K; Matsumoto, S; Oyaizu, H

    1997-10-01

    A huge amount of oil-contaminated soil remains unremediated in the Kuwait desert. The contaminated oil has the potentiality to cause pollution of underground water and to effect the health of people in the neighborhood. In this study, laboratory scale bioremediation experiments were carried out. Hyponex (Hyponex, Inc.) and bark manure were added as basic nutrients for microorganisms, and twelve kinds of materials (baked diatomite, microporous glass, coconut charcoal, an oil-decomposing bacterial mixture (Formula X from Oppenheimer, Inc.), and eight kinds of surfactants) were applied to accelerate the biodegradation of oil hydrocarbons. 15% to 33% of the contaminated oil was decomposed during 43 weeks' incubation. Among the materials tested, coconut charcoal enhanced the biodegradation. On the contrary, the addition of an oil-decomposing bacterial mixture impeded the biodegradation. The effects of the other materials were very slight. The toxicity of the biodegraded compounds was estimated by the Ames test and the tea pollen tube growth test. Both of the hydrophobic (dichloromethane extracts) and hydrophilic (methanol extracts) fractions showed a very slight toxicity in the Ames test. In the tea pollen tube growth test, the hydrophobic fraction was not toxic and enhanced the growth of pollen tubes.

  11. Solvent recycle/contaminant reduction testing - Phase I, Task 3. Topical progress report, June 1994--December 1994

    International Nuclear Information System (INIS)

    1995-07-01

    The Department of Energy (DOE) is now faced with the task of meeting decontamination and decommissioning obligations at numerous facilities by the year 2019. Due to the tremendous volume of material involved, innovative decontamination technologies are being sought that can reduce the volumes of contaminated waste materials and secondary wastes requiring disposal. With sufficient decontamination, some of the material from DOE facilities could be released as scrap into the commercial sector for recycle, thereby reducing the volume of radioactive waste requiring disposal. Although recycling may initially prove to be more costly than current disposal practices, rapidly increasing disposal costs are expected to make recycling more and more cost effective. Additionally, recycling is now perceived as the ethical choice in a world where the consequences of replacing resources and throwing away reusable materials are impacting the well-being of the environment. This report describes the solvent recyle test program for EDTA/ammonium carbonate solvent

  12. [Research on the application of in-situ biological stabilization solidification technology in chromium contaminated site management].

    Science.gov (United States)

    Zhang, Jian-rong; Li, Juan; Xu, Wei

    2013-09-01

    In-situ biological stabilization solidification (SS) technology is an effective ground water risk control method for chromium contaminated sites. Through on-site engineering test, this paper has preliminarily validated the remediation effect of in-situ SS method on a southern chromium contaminated site. The engineering test site has an area of approximately 600 m2, and is located at the upstream of the contaminated area. Due to the severe contamination of chromium, the total chromium concentration reached up to 11,850 mg x kg(-1), while the hexavalent chromium concentration reached up to 349 mg x kg(-1), and the most severely contaminated soil had a depth of -0.5 - -2 m. Variations in hexavalent chromium and total chromium concentration in groundwater were observed through the injection of reducing agents and microbial regulators into the injection wells in the test site, and through the monitoring analysis at different time and different depth under the action of the injection agents. Results of the engineering test showed that the on-site SS technology significantly changed the chromium speciation in soil and then reduced the migration of chromium, thus the groundwater risk was reduced. The injected agents had a good effect of hexavalent chromium remediation in groundwater within the effective range of the injection wells, and the SS rate of hexavalent chromium into trivalent chromium reached 94%-99.9%, the SS rate of total chromium fixation reached 83.9%-99.8%. The test results are of significant reference value for the remediation of contaminated sites with features of shallow groundwater depth and soil mainly consisting of silty clay and sandy clay.

  13. Linking field-based metabolomics and chemical analyses to prioritize contaminants of emerging concern in the Great Lakes basin

    Science.gov (United States)

    Davis, John M.; Ekman, Drew R.; Teng, Quincy; Ankley, Gerald T.; Berninger, Jason P.; Cavallin, Jenna E.; Jensen, Kathleen M.; Kahl, Michael D.; Schroeder, Anthony L.; Villeneuve, Daniel L.; Jorgenson, Zachary G.; Lee, Kathy E.; Collette, Timothy W.

    2016-01-01

    The ability to focus on the most biologically relevant contaminants affecting aquatic ecosystems can be challenging because toxicity-assessment programs have not kept pace with the growing number of contaminants requiring testing. Because it has proven effective at assessing the biological impacts of potentially toxic contaminants, profiling of endogenous metabolites (metabolomics) may help screen out contaminants with a lower likelihood of eliciting biological impacts, thereby prioritizing the most biologically important contaminants. The authors present results from a study that utilized cage-deployed fathead minnows (Pimephales promelas) at 18 sites across the Great Lakes basin. They measured water temperature and contaminant concentrations in water samples (132 contaminants targeted, 86 detected) and used 1H-nuclear magnetic resonance spectroscopy to measure endogenous metabolites in polar extracts of livers. They used partial least-squares regression to compare relative abundances of endogenous metabolites with contaminant concentrations and temperature. The results indicated that profiles of endogenous polar metabolites covaried with at most 49 contaminants. The authors identified up to 52% of detected contaminants as not significantly covarying with changes in endogenous metabolites, suggesting they likely were not eliciting measurable impacts at these sites. This represents a first step in screening for the biological relevance of detected contaminants by shortening lists of contaminants potentially affecting these sites. Such information may allow risk assessors to prioritize contaminants and focus toxicity testing on the most biologically relevant contaminants. Environ Toxicol Chem 2016;35:2493–2502.

  14. A review of groundwater contamination near municipal solid waste landfill sites in China.

    Science.gov (United States)

    Han, Zhiyong; Ma, Haining; Shi, Guozhong; He, Li; Wei, Luoyu; Shi, Qingqing

    2016-11-01

    Landfills are the most widely used method for municipal solid waste (MSW) disposal method in China. However, these facilities have caused serious groundwater contamination due to the leakage of leachate. This study, analyzed 32 scientific papers, a field survey and an environmental assessment report related to groundwater contamination caused by landfills in China. The groundwater quality in the vicinity of landfills was assessed as "very bad" by a comprehensive score (FI) of 7.85 by the Grading Method in China. Variety of pollutants consisting of 96 groundwater pollutants, 3 organic matter indicators, 2 visual pollutants and 6 aggregative pollutants had been detected in the various studies. Twenty-two kinds of pollutants were considered to be dominant. According to the Kruskal-Wallis test and the median test, groundwater contamination differed significantly between regions in China, but there were no significant differences between dry season and wet season measurements, except for some pollutants in a few landfill sites. Generally, the groundwater contamination appeared in the initial landfill stage after five years and peaked some years afterward. In this stage, the Nemerow Index (PI) of groundwater increased exponentially as landfill age increased at some sites, but afterwards decreased exponentially with increasing age at others. After 25years, the groundwater contamination was very low at selected landfills. The PI values of landfills decreased exponentially as the pollutant migration distance increased. Therefore, the groundwater contamination mainly appeared within 1000m of a landfill and most of serious groundwater contamination occurred within 200m. The results not only indicate that the groundwater contamination near MSW landfills should be a concern, but also are valuable to remediate the groundwater contamination near MSW landfills and to prevent the MSW landfill from secondary pollutions, especially for developing countries considering the similar

  15. New closed tube loop mediated isothermal amplification assay for prevention of product cross-contamination

    OpenAIRE

    Karthik, K.; Rathore, Rajesh; Thomas, Prasad; Arun, T.R.; Viswas, K.N.; Dhama, Kuldeep; Agarwal, R.K.

    2014-01-01

    Loop mediated isothermal amplification (LAMP) assay, a promising diagnostic test, has been developed for detection of different pathogens of human as well as animals. Various positive points support its use as a field level test but the major problem is product cross contamination leading to false positive results. Different methods were adopted by various researchers to control this false positive amplification due to cross contamination but all have their own advantages and disadvantages. A...

  16. Microbial contamination of mobile phones in a health care setting in Alexandria, Egypt.

    Science.gov (United States)

    Selim, Heba Sayed; Abaza, Amani Farouk

    2015-01-01

    This study aimed at investigating the microbial contamination of mobile phones in a hospital setting. Swab samples were collected from 40 mobile phones of patients and health care workers at the Alexandria University Students' Hospital. They were tested for their bacterial contamination at the microbiology laboratory of the High Institute of Public Health. Quantification of bacteria was performed using both surface spread and pour plate methods. Isolated bacterial agents were identified using standard microbiological methods. Methicillin-resistant Staphylococcus aureus was identified by disk diffusion method described by Bauer and Kirby. Isolated Gram-negative bacilli were tested for being extended spectrum beta lactamase producers using the double disk diffusion method according to the Clinical and Laboratory Standards Institute recommendations. All of the tested mobile phones (100%) were contaminated with either single or mixed bacterial agents. The most prevalent bacterial contaminants were methicillin-resistant S. aureus and coagulase-negative staphylococci representing 53% and 50%, respectively. The mean bacterial count was 357 CFU/ml, while the median was 13 CFU/ml using the pour plate method. The corresponding figures were 2,192 and 1,720 organisms/phone using the surface spread method. Mobile phones usage in hospital settings poses a risk of transmission of a variety of bacterial agents including multidrug-resistant pathogens as methicillin-resistant S. aureus. The surface spread method is an easy and useful tool for detection and estimation of bacterial contamination of mobile phones.

  17. LERF Basin 44 Process Test Plan

    International Nuclear Information System (INIS)

    LUECK, K.J.

    1999-01-01

    This document presents a plan to process a portion of the Liquid Effluent Retention Facility (LERF) Basin 44 wastewater through the 200 Area Effluent Treatment Facility (ETF). The objective of this process test is to determine the most effective/efficient method to treat the wastewater currently stored in LERF Basin 44. The process test will determine the operational parameters necessary to comply with facility effluent discharge permit limits (Ecology 1995) and the Environmental Restoration Disposal Facility (ERDF) acceptance criteria (BHI-00139), while achieving ALARA goals and maintaining the integrity of facility equipment. A major focus of the test plan centers on control of contamination due to leaks and/or facility maintenance. As a pre-startup item, all known leaks will be fixed before the start of the test. During the course of the test, a variety of contamination control measures will be evaluated for implementation during the treatment of the remaining Basin 44 inventory. Of special interest will be techniques and tools used to prevent contamination spread during sampling and when opening contaminated facility equipment/piping. At the conclusion of the test, a post ALARA review will be performed to identify lessons learned from the test run which can be applied to the treatment of the remaining Basin 44 inventory. The volume of wastewater to be treated during this test run is 500,000 gallons. This volume limit is necessary to maintain the ETF radiological inventory limits per the approved authorization basis. The duration of the process test is approximately 30 days

  18. Petrol contaminated groundwater treatment with air-stripper in Balassagyarmat, Hungary

    International Nuclear Information System (INIS)

    Szabo, Peter; Bernath, Balazs

    2005-01-01

    Hydrocarbon contaminated groundwater is a common environmental problem in Hungary. Leakage of underground storage tanks, pipe break or illegal tapping as well as lorry accidents can be mentioned as main reasons. MEGATERRA Ltd. elaborated, adopted and tested several groundwater clean-up methods. These methods are based on detailed survey and investigation, sampling and analysis, delineation of contaminated groundwater, risk assessment, establishment of monitoring wells, pumping tests and remediation action plan. One of these methods was implemented by MEGATERRA Ltd. in Balassagyarmat, Hungary. Contamination source was a 10 m 3 vol. simple wall underground fuel-storage tank, which had been emptied. When the remediation started in April 1998, the petrol had already been accumulated on the ground water table forming a 5-7 m wide and 10-15 m long plume being expanded to SSE-NNW direction. The area of the dissolved hydrocarbon contaminated groundwater-body was 1 000 m 2 and its concentration reached up to 30-40 mg/l TPH. The free-phase hydrocarbon layer was 10 cm thick. For the remediation of contaminated groundwater MEGATERRA Ltd. applied pump and treat method, namely groundwater pumping using extraction well, skimming of free-phase hydrocarbon, stripping of the contaminated ground water in air-stripper tower and draining of the treated groundwater into a drainage ditch. In the centre of the plume we established an extraction well with 300 mm diameter in a 500 mm borehole. Peristaltic skimmer pump was used inside the extraction well to remove the free phase petrol from the ground water surface.Because of the intense volatility of the pollutant we applied aeration (stripping) technology. The extracted contaminated groundwater was cleaned in air-stripper equipment being able to eliminate efficiently the volatile pollutants from the water. The aeration tower is a compact cylindrical shaped column with 650 mm in diameter. Its height depends on the pollutant's type The

  19. Microbial contamination of water-soaked cotton gauze and its cause.

    Science.gov (United States)

    Oie, S; Yoshida, H; Kamiya, A

    2001-01-01

    Seven in-use cotton gauze samples and three cotton balls soaked in sterile distilled water in canisters were investigated 7 days after they were prepared in hospital. All samples were contaminated with bacteria including 10(6) to 10(7) colony forming units/ml of Pseudomonas aeruginosa. In vitro viability tests using cotton gauze and cotton balls soaked in sterile distilled water revealed rapid proliferation of P. aeruginosa, Serratia marcescens and Candida albicans. Since the cotton gauze and the cotton balls were soaked in water containing nutrients, such as protein and glucose, these materials may be readily contaminated with bacteria including P. aeruginosa. Thus, when using cotton gauze and cotton balls containing water, microbial contamination should be expected.

  20. Focused evaluation of selected remedial alternatives for the underground test area

    International Nuclear Information System (INIS)

    1997-04-01

    The Nevada Test Site (NTS), located in Nye County in southern Nevada, was the location of 928 nuclear tests conducted between 1951 and 1992. Of the total tests, 824 were nuclear tests performed underground. This report describes the approach taken to determine whether any specific, proven, cost-effective technologies currently exist to aid in the removal of the radioactive contaminants from the groundwater, in the stabilization of these contaminants, and in the removal of the source of the contaminants

  1. Ecotoxicological effects of decabromodiphenyl ether and cadmium contamination on soil microbes and enzymes.

    Science.gov (United States)

    Zhang, Wei; Zhang, Meng; An, Shuai; Xiong, Bang; Li, Hui; Cui, Changzheng; Lin, Kuangfei

    2012-08-01

    The ecotoxicological effects of decabromodiphenyl ether (BDE209) and cadmium (Cd) contamination on soil culturable microbial population, enzyme activity and bacterial community structure were investigated. Results of the indoor incubation test runs performed on many series of control and contaminated soil samples have demonstrated some notable toxic effects due to long term exposure to either or both contaminants. The two contaminants produced notable yet different toxic effects on the test microbes; the population of the exposed species generally declined according to certain dose-response relationships. The soil culturable microbial population and enzyme activity data show that the sensitivity to one or both contaminants followed the order of: bacteria>fungi>actinomycete and urease>saccharase, respectively. The interaction between BDE209 and Cd was dependent on both the exposure dose and time and that the joint toxic effects were synergistic, antagonistic or additive. The PCR-DGGE analysis data of species composition and richness suggest the synergistic combined effects on bacterial community structure during the 30d exposure. Pseudomonas tuomuerensis strain CCM 7280 and Pseudomonas alcaliphila strain AL15-21 were enriched, indicating these species might be major functional populations and highly tolerant. Such observations have provided the useful information of potential ecotoxicological effects of BDE209 and Cd contamination in the environment. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Measurement of radioactivity in contaminated crops

    Energy Technology Data Exchange (ETDEWEB)

    Yamada, Y; Hasegawa, M; Kihara, T

    1956-01-01

    A method called the Direct Method was developed to correct for natural /sup 40/K radiation in plant samples. The K content of the ashed sample is determined by flamephotometry. The radioactivity in a 100 mg sample is measured and the natural radioactivity from /sup 40/K determined by calculation subtracted. Tea samples tested gave evidence of contamination by radioactive fallout.

  3. Contaminated water treatment

    Science.gov (United States)

    Gormly, Sherwin J. (Inventor); Flynn, Michael T. (Inventor)

    2010-01-01

    Method and system for processing of a liquid ("contaminant liquid") containing water and containing urine and/or other contaminants in a two step process. Urine, or a contaminated liquid similar to and/or containing urine and thus having a relatively high salt and urea content is passed through an activated carbon filter to provide a resulting liquid, to remove most of the organic molecules. The resulting liquid is passed through a semipermeable membrane from a membrane first side to a membrane second side, where a fortified drink having a lower water concentration (higher osmotic potential) than the resulting liquid is positioned. Osmotic pressure differential causes the water, but not most of the remaining inorganic (salts) contaminant(s) to pass through the membrane to the fortified drink. Optionally, the resulting liquid is allowed to precipitate additional organic molecules before passage through the membrane.

  4. Removal of petroleum-derived hydrocarbons from contaminated soils by solvent extraction

    International Nuclear Information System (INIS)

    Ladanowski, C.; Petti, L.

    1993-01-01

    Laboratory studies were conducted using hexane for the removal of light crude oil from contaminated sand, peat, and clay soils. The bench-scale process tested consists of three major steps: solvent washing, settling/decantation/filtration of extract, and solvent recycle. The results indicate that the use of solvent extraction for cleanup of oil-contaminated soils is an effective technology at the bench-scale level. Using a 1,000 g batch system, extremely high oil removal efficiencies were obtained from contaminated sand (up to 98.9%) and peat soil (up to 83.9%). The final oil contaminant concentration for sand varied between 0.06% and 0.39%, while that for peat soil varied between 1.52% and 5.21%. The guidelines for the decommissioning and cleanup of sites in Ontario for oil and grease (1 wt %) were met in all instances for the treated sand. Hexane recovery from diesel-contaminated sand and peat soil experiments was ca 81% and 67% respectively. 4 refs., 6 figs., 10 tabs

  5. [Disinfectants and main sanitary and preventive measures for protection of ventilation and air-conditioning systems from Legionella contamination].

    Science.gov (United States)

    Gerasimov, V N; Golov, E A; Khramov, M V; Diatlov, I A

    2008-01-01

    The study was devoted to selection and assessment of disinfecting preparations for prevention of contamination by Legionella. Using system of criteria for quality assessment of disinfectants, seven newdomestic ones belonging to quaternary ammonium compounds class or to oxygen-containing preparations and designed for disinfecting of air-conditioning and ventilation systems were selected. Antibacterial and disinfecting activities of working solutions of disinfectants were tested in laboratory on the test-surfaces and test-objects of premises' air-conditioning and ventilation systems contaminated with Legionella. High antimicrobial and disinfecting activity of new preparations "Dezactiv-M", "ExtraDez", "Emital-Garant", "Aquasept Plus", "Samarovka", "Freesept", and "Ecobreeze Oxy" during their exposure on objects and materials contaminated with Legionella was shown. Main sanitary and preventive measures for defending of air-conditioning and ventilation systems from contamination by Legionella species were presented.

  6. Application of different measures of bioavailability to support the derivation of risk-based remedial benchmarks for PHC-contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Stephenson, G. [Stantec Consulting Ltd., Surrey, BC (Canada)

    2009-07-01

    Risk estimates and exposure scenarios hardly ever take into consideration site-specific bioavailability of contaminants. Risk assessors frequently adopt the assumption that a contaminant in soils is 100 percent bioavailable, resulting in an overestimation of the risks associated with contamination. Remedial targets or benchmarks derived in light of this assumption are needlessly low and might be technically unattainable or prohibitive in terms of cost. This presentation discussed a research project whose goal was to develop a tool kit to measure or determine site-specific bioavailability of contaminants (PHCs) in soils to ecological receptors. Tools that were discussed included: biological measures such as toxicity tests, contaminant residues in tissues, and bioaccumulation tests. Chemical measures such as bioaccessibility tests and other biomimetic devices (SPMDs), biotic ligand modeling, and chemical extractions were also presented. Preliminary investigation results were provided. Other topics that were discussed included: single-species toxicity tests; preliminary comparisons; the site; bioaccumulation; and toxicity to earthworms. It was concluded that total soil and water-extractable concentrations did not correlate well with toxicity. tabs., figs.

  7. Rapid and robust detection methods for poison and microbial contamination.

    Science.gov (United States)

    Hoehl, Melanie M; Lu, Peter J; Sims, Peter A; Slocum, Alexander H

    2012-06-27

    Real-time on-site monitoring of analytes is currently in high demand for food contamination, water, medicines, and ingestible household products that were never tested appropriately. Here we introduce chemical methods for the rapid quantification of a wide range of chemical and microbial contaminations using a simple instrument. Within the testing procedure, we used a multichannel, multisample, UV-vis spectrophotometer/fluorometer that employs two frequencies of light simultaneously to interrogate the sample. We present new enzyme- and dye-based methods to detect (di)ethylene glycol in consumables above 0.1 wt % without interference and alcohols above 1 ppb. Using DNA intercalating dyes, we can detect a range of pathogens ( E. coli , Salmonella , V. Cholera, and a model for Malaria) in water, foods, and blood without background signal. We achieved universal scaling independent of pathogen size above 10(4) CFU/mL by taking advantage of the simultaneous measurement at multiple wavelengths. We can detect contaminants directly, without separation, purification, concentration, or incubation. Our chemistry is stable to ± 1% for >3 weeks without refrigeration, and measurements require <5 min.

  8. Testing a community water supply well located near a stream for susceptibility to stream contamination and low-flows.

    Science.gov (United States)

    Stewart-Maddox, N. S.; Tysor, E. H.; Swanson, J.; Degon, A.; Howard, J.; Tsinnajinnie, L.; Frisbee, M. D.; Wilson, J. L.; Newman, B. D.

    2014-12-01

    A community well is the primary water supply to the town of El Rito. This small rural town in is located in a semi-arid, mountainous portion of northern New Mexico where water is scarce. The well is 72 meters from a nearby intermittent stream. Initial tritium sampling suggests a groundwater connection between the stream and well. The community is concerned with the sustainability and future quality of the well water. If this well is as tightly connected to the stream as the tritium data suggests, then the well is potentially at risk due to upstream contamination and the impacts of extended drought. To examine this, we observed the well over a two-week period performing pump and recovery tests, electrical resistivity surveys, and physical observations of the nearby stream. We also collected general chemistry, stable isotope and radon samples from the well and stream. Despite the large well diameter, our pump test data exhibited behavior similar to a Theis curve, but the rate of drawdown decreased below the Theis curve late in the test. This decrease suggests that the aquifer is being recharged, possibly through delayed yield, upwelling of groundwater, or from the stream. The delayed yield hypothesis is supported by our electrical resistivity surveys, which shows very little change in the saturated zone over the course of the pump test, and by low values of pump-test estimated aquifer storativity. Observations of the nearby stream showed no change in stream-water level throughout the pump test. Together this data suggests that the interaction between the stream and the well is low, but recharge could be occurring through other mechanisms such as delayed yield. Additional pump tests of longer duration are required to determine the exact nature of the aquifer and its communication with the well.

  9. Urban atmospheric contamination

    International Nuclear Information System (INIS)

    Baldasano Jose, M.

    1997-01-01

    The problems of contamination are not only limited to this century, pale pathology evidences of the effects of the contamination of the air exist in interiors in the health of the old ones; the article mention the elements that configure the problem of the atmospheric contamination, atmospheric pollutants and emission sources, orography condition and effects induced by the urbanization process

  10. Summary report of the grazing studies conducted on a plutonium-contaminated range in Area 13 of the Nevada Test Site

    International Nuclear Information System (INIS)

    Smith, D.D.

    1979-05-01

    Actinide concentrations in the tissues of beef animals periodically sacrificed and sampled during a 3-year grazing study on a plutonium-contaminated range of the Nevada Test Site are tabulated and discussed. The primary objective of this study was to determine the uptake and tissue distribution of the plutonium by ruminants. Food habit analyses of ingesta from rumen-fistulated steers and sacrificed cattle revealed that shrub species made up the major portion of their diet during most seasons of the year. Grasses were preferred during the spring months. Using activity levels found in the rumen contents, it was estimated that a study cow ingested 100 microcuries of plutonium-239 prior to sacrifice. Of this, 16.4 microcuries was in rumen fluids from which a combined retention factor of 0.0034% was calculated for the bone, muscle, and liver. Comparisons of plutonium-239/plutonium-238 ratios in ingesta and tissues indicate that the plutonium-238 is more readily absorbed and retained. No radiologically significant lesions were found. The gonadal concentrations of the actinides were significantly higher than those of blood and muscle and approached those of bone. These data indicate that consideration should be given to the plutonium-239 dose to gonads as well as that to bone, liver, and lungs of man. Actinide concentrations of animals born in the study areas showed an increasing trend with time. Concentrations of plutonium-239 in the lung, liver, muscle, and femur tissues of the Area 13 cattle were significantly higher than in tissues collected from grazing cattle from other sites. The plutonium-239 concentrations in bones, lungs, and livers collected from wildlife with free access to and from the contaminated zones reflect the dilution resulting from these animals ranging into the less contaminated areas around the study sites

  11. Influence of hang time and location on bacterial contamination of intravenous bags in a veterinary emergency and critical care setting.

    Science.gov (United States)

    Guillaumin, Julien; Olp, Nichole M; Magnusson, Karissa D; Butler, Amy L; Daniels, Joshua B

    2017-09-01

    To assess the rate of bacterial contamination of fluid and ports in intravenous bags in a veterinary emergency room (ER) and intensive care unit (ICU). Experimental model. Ninety intravenous fluid bags of lactated balanced-electrolytes solution (1 L) hung in a university hospital. Bags were hung in 2 different locations in the ER (sink and bins) and one location in the ICU (sink) for 11 days. Bags were punctured 3 times daily with a sterile needle to simulate clinical use. Injection ports were swabbed and 50 mL of fluid were collected in duplicates on days 0, 2, 4, 7, and 10. Aerobic bacterial cultures were performed on the fluid and injection port. Contamination was defined as bacterial growth of a similar phenotype across 2 consecutive times. Increase in the fluid contamination rate from day 0 was tested using an exact binomial test. Port contamination rate between locations was tested using Fisher's exact test. Combined bacterial growth on injection ports reached a mean (95% confidence interval) of 8.1 (0.005-16.2) cfu/port on day 10. The combined port contamination was 3.3%, 11.1%, 17.8%, and 31.1% on days 0, 2, 4, and 7, respectively. Port contamination was similar between ER and ICU. However, port contamination was higher in the sink versus the bins area (38.3% vs 16.7%, P = 0.032). No fluid bag was contaminated at days 0 and 2. The contamination rate of fluid bag was 1.1% and 4.4% on days 4 and 7, respectively. All bags with contaminated fluid were in the ER (6.7%, 95% exact binomial confidence interval 1.9-16.2%). Injection port contamination reached 31.1% on day 7. Contamination was more likely when the bags were hung next to a sink. In our model of bag puncture, fluid contamination occurred between days 2 and 4. © Veterinary Emergency and Critical Care Society 2017.

  12. In situ respiration testing: A field treatability test for bioventing

    International Nuclear Information System (INIS)

    Kittel, J.A.; Hinchee, R.E.; Miller, R.; Vogel, C.; Hoeppel, R.

    1993-01-01

    Bioventing is the process of aerating subsurface soils to stimulate in situ biological activity and promote bioremediation. Bioventing differs from soil venting in remedial approach. Soil venting is designed and operated to maximize the volatilization of low-molecular-weight compounds, with some biodegradation occurring. In contrast, bioventing is designed to maximize biodegradation of aerobically biodegradable compounds, regardless of their molecular weight, with some volatilization occurring. Bioventing is gaining wide acceptance as a remediation alternative at petroleum-contaminated sites. However, site variability usually requires that a short term treatability test be conducted in situ at potential sites to determine the applicability of bioventing. Battelle has worked with the US Air Force and the US Navy to develop a simple and inexpensive field test to evaluate bioventing potential-contaminated sites. This test has been used to evaluate the applicability of bioventing at over 50 sites. The in situ respiration test consists of injecting air and an inert tracer gas (helium) over a 24-hour period to aerate soils at an oxygen-deficient, petroleum-contaminated site. Soil vapor samples are collected to determine oxygen utilization rates and carbon dioxide production rates. The stoichiometric relationship for the oxidation of hexane is used to calculate the biodegradation rate. The tracer gas is monitored to estimate the effect of diffusion on changes in soil-gas concentrations

  13. Comparison of two possible routes of pathogen contamination of spinach leaves in a hydroponic cultivation system.

    Science.gov (United States)

    Koseki, Shigenobu; Mizuno, Yasuko; Yamamoto, Kazutaka

    2011-09-01

    The route of pathogen contamination (from roots versus from leaves) of spinach leaves was investigated with a hydroponic cultivation system. Three major bacterial pathogens, Escherichia coli O157:H7, Salmonella, and Listeria monocytogenes, were inoculated into the hydroponic solution, in which the spinach was grown to give concentrations of 10⁶ and 10³ CFU/ml. In parallel, the pathogens were inoculated onto the growing leaf surface by pipetting, to give concentrations of 10⁶ and 10³ CFU per leaf. Although contamination was observed at a high rate through the root system by the higher inoculum (10⁶ CFU) for all the pathogens tested, the contamination was rare when the lower inoculum (10³ CFU) was applied. In contrast, contamination through the leaf occurred at a very low rate, even when the inoculum level was high. For all the pathogens tested in the present study, the probability of contamination was promoted through the roots and with higher inoculum levels. The probability of contamination was analyzed with logistic regression. The logistic regression model showed that the odds ratio of contamination from the roots versus from the leaves was 6.93, which suggested that the risk of contamination from the roots was 6.93 times higher than the risk of contamination from the leaves. In addition, the risk of contamination by L. monocytogenes was about 0.3 times that of Salmonella enterica subsp. enterica serovars Typhimurium and Enteritidis and E. coli O157:H7. The results of the present study indicate that the principal route of pathogen contamination of growing spinach leaves in a hydroponic system is from the plant's roots, rather than from leaf contamination itself.

  14. Wastewater canal Vojlovica, industrial complex Pančevo, Serbia – preliminary ecotoxicological assessment of contaminated sediment

    Directory of Open Access Journals (Sweden)

    IVANA PLANOJEVIĆ

    2011-03-01

    Full Text Available Effluents collected from the industrial complex of Pančevo, Serbia (oil refinery, petrochemical plant, and fertilizer factory, are discharged into a wastewater canal entering the Danube River. In this study, which was focused on sediment assessment, a complex triad approach consisting of chemical analysis, sediment toxicity tests and macrozoobenthos community analysis was applied. In toxicity tests on sediment elutriates, the following responses were registered – stimulatory effect in algal bioassay, no effect in acute test with Daphnia magna, and low to moderate toxicity in the conventional Vibrio fischeri test. Moderate to high toxicities were recorded in solid phase tests on Myriophyllum aquaticum and V. fischeri. High content of Hg, certain PAHs and non-characterised sediment contaminants accumulated over years contribute not only to the registered toxicity, but also to the complete absence of macrozoobenthos. The obtained results proved that regularly measured conventional and priority pollutants are hardly ever the only toxic contaminants present in sediments. Toxicity tests, in particular the contact test, might guide towards a better selection of parameters to be regularly or occasionally monitored. In addition, complete sediment toxicity tests proved to be an appropriate method for assessing the bioavailability of the chemically detected contaminants. The analysis of the macrozoobenthos composition and structure as inevitable part of sediment risk assessment procedures integrates the effects of multiple stressors and gives a realistic insight into not only sediment contamination by toxic pollutants, but also the sediment status in general.

  15. Contamination sources, prevention, and research

    Science.gov (United States)

    Contamination is defined as anything other than cotton in cotton lint. Worldwide, contamination is on the rise and plastic contamination has increased at a faster rate than contamination overall. In the U.S., there are many sources of plastic contaminants, such as plastic trash that collects in cott...

  16. Release of Streptomyces albus propagules from contaminated surfaces

    International Nuclear Information System (INIS)

    Gorny, R.L.; Mainelis, Gediminas; Grinshpun, Sergey A.; Willeke, Klaus; Dutkiewicz, Jacek; Reponen, Tiina

    2003-01-01

    The release of Streptomyces albus propagules from contaminated agar an ceiling tile surfaces was studied under controlled environmental condition in a newly developed aerosolization chamber. The experiments revealed tha both spores and cell fragments can be simultaneously released from the colonized surface by relatively gentle air currents of 0.3 m s -1 . A 100x increase of the air velocity can result in a 50-fold increase in the number of released propagules. The aerosolization rate depends strongly on the typ and roughness of the contaminated surface. Up to 90% of available actinomycete propagules can become airborne during the first 10 min of th release process. Application of vibration to the surface did not reveal an influence on the aerosolization process of S. albus propagules under th tested conditions. This study has shown that propagules in the fine particle size range can be released in large amounts from contaminated surfaces Measurement of the number of S. albus fragments in the vicinity of contaminated area, as an alternative to conventional air or surface sampling appears to be a promising approach for quantitative exposure assessment

  17. High-quality endoscope reprocessing decreases endoscope contamination.

    Science.gov (United States)

    Decristoforo, P; Kaltseis, J; Fritz, A; Edlinger, M; Posch, W; Wilflingseder, D; Lass-Flörl, C; Orth-Höller, D

    2018-02-24

    Several outbreaks of severe infections due to contamination of gastrointestinal (GI) endoscopes, mainly duodenoscopes, have been described. The rate of microbial endoscope contamination varies dramatically in literature. The aim of this multicentre prospective study was to evaluate the hygiene quality of endoscopes and automated endoscope reprocessors (AERs) in Tyrol/Austria. In 2015 and 2016, a total of 463 GI endoscopes and 105 AERs from 29 endoscopy centres were analysed by a routine (R) and a combined routine and advanced (CRA) sampling procedure and investigated for microbial contamination by culture-based and molecular-based analyses. The contamination rate of GI endoscopes was 1.3%-4.6% according to the national guideline, suggesting that 1.3-4.6 patients out of 100 could have had contacts with hygiene-relevant microorganisms through an endoscopic intervention. Comparison of R and CRA sampling showed 1.8% of R versus 4.6% of CRA failing the acceptance criteria in phase I and 1.3% of R versus 3.0% of CRA samples failing in phase II. The most commonly identified indicator organism was Pseudomonas spp., mainly Pseudomonas oleovorans. None of the tested viruses were detected in 40 samples. While AERs in phase I failed (n = 9, 17.6%) mainly due to technical faults, phase II revealed lapses (n = 6, 11.5%) only on account of microbial contamination of the last rinsing water, mainly with Pseudomonas spp. In the present study the contamination rate of endoscopes was low compared with results from other European countries, possibly due to the high quality of endoscope reprocessing, drying and storage. Copyright © 2018 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  18. Monitoring of tritium-contaminated surfaces, including skin

    Energy Technology Data Exchange (ETDEWEB)

    Surette, R A; Wood, M J

    1994-05-01

    We have examined various commercially available tritium surface contamination monitors along with different swipe media and techniques for direct and indirect (swipe) monitoring of contaminated surfaces, including skin. None of the methods or instruments evaluated were more sensitive than the swipe and liquid scintillation counting (LSC) method. Swipe measurements with open-window proportional counters were, in general, less than half as sensitive as LSC, but have the advantages of having the results available almost immediately, and no sample preparation is required. The Nuclear Measurement Corporation`s PC-55 is the most suitable instrument we tested for the analysis of routine swipe measurement. The PC-55 was about one third as sensitive as LSC when used with Ontario Hydro filter paper swipe media. Surface contamination measurement results can be obtained within minutes using the PC-55, compared to hours using LSC. The selection of swipe media for use with proportional counter-based instruments is critical. A medium that is electrically insulating can develop an electrostatic charge on its surface; this may alter the field gradient in the detector and may adversely influence the results. Although the PC-55 is sufficiently sensitive and very convenient, operational experience with the instrument is needed before recommending that it replace current LSC methods. The PC-55`s susceptibility to internal tritium contamination may limit its practical usefulness. Because of the complexity of using live animals to evaluate direct and indirect methods for assessing skin contamination, pig skin was investigated as a possible substitute. We concluded that, for the first few hours post-exposure, pig skin mimics the kinetics of animal skin that has contacted a tritium-contaminated surface. (author). 30 refs., 1 tab., 7 figs.

  19. Environmental contamination, product contamination and workers exposure using a robotic system for antineoplastic drug preparation.

    Science.gov (United States)

    Sessink, Paul J M; Leclercq, Gisèle M; Wouters, Dominique-Marie; Halbardier, Loïc; Hammad, Chaïma; Kassoul, Nassima

    2015-04-01

    Environmental contamination, product contamination and technicians exposure were measured following preparation of iv bags with cyclophosphamide using the robotic system CytoCare. Wipe samples were taken inside CytoCare, in the clean room environment, from vials, and prepared iv bags including ports and analysed for contamination with cyclophosphamide. Contamination with cyclophosphamide was also measured in environmental air and on the technicians hands and gloves used for handling the drugs. Exposure of the technicians to cyclophosphamide was measured by analysis of cyclophosphamide in urine. Contamination with cyclophosphamide was mainly observed inside CytoCare, before preparation, after preparation and after daily routine cleaning. Contamination outside CytoCare was incidentally found. All vials with reconstituted cyclophosphamide entering CytoCare were contaminated on the outside but vials with powdered cyclophosphamide were not contaminated on the outside. Contaminated bags entering CytoCare were also contaminated after preparation but non-contaminated bags were not contaminated after preparation. Cyclophosphamide was detected on the ports of all prepared bags. Almost all outer pairs of gloves used for preparation and daily routine cleaning were contaminated with cyclophosphamide. Cyclophosphamide was not found on the inner pairs of gloves and on the hands of the technicians. Cyclophosphamide was not detected in the stationary and personal air samples and in the urine samples of the technicians. CytoCare enables the preparation of cyclophosphamide with low levels of environmental contamination and product contamination and no measurable exposure of the technicians. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  20. Frequencies of micro-nucleated lymphocytes and Epstein-Barr virus contamination in Altay region residents living near the Semipalatinsk atomic testing ground

    International Nuclear Information System (INIS)

    Ilyinskikh, N.N.; Ilyinskikh, E.N.; Yurkin, A.Yu.; Ilyinskikh, I.N.

    2003-01-01

    We have assessed frequencies of micro-nucleated lymphocytes in 3036 individuals living in 16 settlements in the west of the Altay region. Among the settlements the majority of individuals with significantly high frequencies of micro-nucleated lymphocytes were detected in settlements adjacent to the Semipalatinsk atomic testing ground (SATG). The most considerable genome instability was found in the individuals born in the period of intensive testing on the SATG (from 1949 to 1962). Moreover, we have determined that the residents of the settlements adjacent to the SATG have significantly high levels of antibodies to potentially oncogenic Epstein-Barr virus besides high frequencies of micro-nucleated lymphocytes. The considerable Epstein-Barr virus contamination among the residents in the radiation polluted zone around the SATG was supposed to be caused by immunodeficiency disorders in these individuals and induce high frequencies of micro-nucleated cells. (author)

  1. Phytoremediation of soil contaminated with low concentrations of radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Entry, J A; Vance, N C; Hamilton, M A; Zabowski, D; Watrud, L S; Adriano, D C [Auburn University, Auburn, AL (United States). Dept. of Agronomy and Soils

    1996-03-01

    Ecsosytems throughout the world have been contaminated with radionuclides by above-ground nuclear testing, nuclear reactor accidents and nuclear power generation. Radioisotopes characteristics of nuclear fission, such as {sup 137}Cs and {sup 90}Sr, that are released into the environment can become more concentrated as they move up the food chain often becoming human health hazards. Natural environmental processes will redistribute long lived radionuclides that are released into the environment among soil, plants and wildlife. Numerous studies have shown that {sup 137}Cs and {sup 90}Sr are not removed from the top 0.4 metres of soil even under high rainfall, and migration rate from the top few centimetres of soil is slow. The top 0.4 meters of the soil is where plant roots actively accumulate elements. Since plants are known to take up and accumulate {sup 137}Cs and {sup 90}Sr, removal of these radionuclides from contaminated soils by plants could provide a reliable and economical method of remediation. One approach is to use fast growing plants inoculated with mycorrhizal fungi combined with soil organic amendments to maximize the plant accumulation and removal of radionuclides from contaminated soils, followed by harvest of above-ground portion of the plants. High temperature combustion would be used to oxidize plant material concentrating {sup 137}Cs and {sup 90}Sr in ash for disposal. When areas of land have been contaminated with radionuclides are large, using energy intensive engineering solutions to mediate huge volumes of soil is not feasible or economical. Plants are proposed as a viable and cost effective method to remove radionuclides from the soils that have been contaminated by nuclear testing and nuclear reactor accidents. 40 refs.

  2. Removal of uranium from uranium-contaminated soils -- Phase 1: Bench-scale testing

    International Nuclear Information System (INIS)

    Francis, C.W.

    1993-09-01

    To address the management of uranium-contaminated soils at Fernald and other DOE sites, the DOE Office of Technology Development formed the Uranium in Soils Integrated Demonstration (USID) program. The USID has five major tasks. These include the development and demonstration of technologies that are able to (1) characterize the uranium in soil, (2) decontaminate or remove uranium from the soil, (3) treat the soil and dispose of any waste, (4) establish performance assessments, and (5) meet necessary state and federal regulations. This report deals with soil decontamination or removal of uranium from contaminated soils. The report was compiled by the USID task group that addresses soil decontamination; includes data from projects under the management of four DOE facilities [Argonne National Laboratory (ANL), Los Alamos National Laboratory (LANL), Oak Ridge National Laboratory (ORNL), and the Savannah River Plant (SRP)]; and consists of four separate reports written by staff at these facilities. The fundamental goal of the soil decontamination task group has been the selective extraction/leaching or removal of uranium from soil faster, cheaper, and safer than current conventional technologies. The objective is to selectively remove uranium from soil without seriously degrading the soil's physicochemical characteristics or generating waste forms that are difficult to manage and/or dispose of. Emphasis in research was placed more strongly on chemical extraction techniques than physical extraction techniques

  3. Potential of near-infrared hyperspectral reflectance imaging for screening of farm feed contamination

    Science.gov (United States)

    Wang, Wenbo; Paliwal, Jitendra

    2005-09-01

    With the outbreak of Bovine Spongiform Encephalopathy (BSE) (commonly known as mad cow disease) in 1987 in the United Kingdom and a recent case discovered in Alberta, more and more emphasis is placed on food and farm feed quality and safety issues internationally. The disease is believed to be spread through farm feed contamination by animal byproducts in the form of meat-and-bone-meal (MBM). The paper reviewed the available techniques necessary to the enforcement of legislation concerning the feed safety issues. The standard microscopy method, although highly sensitive, is laborious and costly. A method to routinely screen farm feed contamination certainly helps to reduce the complexity of safety inspection. A hyperspectral imaging system working in the near-infrared wavelength region of 1100-1600 nm was used to study the possibility of detection of ground broiler feed contamination by ground pork. Hyperspectral images of raw broiler feed, ground broiler feed, ground pork, and contaminated feed samples were acquired. Raw broiler feed samples were found to possess comparatively large spectral variations due to light scattering effect. Ground feed adulterated with 1%, 3%, 5%, and 10% of ground pork was tested to identify feed contamination. Discriminant analysis using Mahalanobis distance showed that the model trained using pure ground feed samples and pure ground pork samples resulted in 100% false negative errors for all test replicates of contaminated samples. A discriminant model trained with pure ground feed samples and 10% contamination level samples resulted in 12.5% false positive error and 0% false negative error.

  4. Laboratory evaluation of the potential for in situ treatment of chromate-contaminated groundwater by chemical precipitation

    International Nuclear Information System (INIS)

    Thornton, E.C.; Beck, M.A.; Jurgensmeier, C.A.

    1995-03-01

    The objective of this paper is to present the results of a series of small-scale batch tests performed to assess the effectiveness of chemical precipitation in the remediation of chromate-contaminated groundwater. These tests involved treatment of chromate solutions with ferrous and sulfide ions. In addition, tests were conducted that involved treatment of mixtures of chromate-contaminated groundwater and uncontaminated soil with the ferrous ion. A combination of ferrous sulfate and sodium sulfide was also tested in the groundwater treatment tests, since this approach has been shown to be an efficient method for treating electroplating wastewaters

  5. Closure Report for Corrective Action Unit 166: Storage Yards and Contaminated Materials, Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Restoration

    2009-08-01

    Corrective Action Unit (CAU) 166 is identified in the Federal Facility Agreement and Consent Order (FFACO) as 'Storage Yards and Contaminated Materials' and consists of the following seven Corrective Action Sites (CASs), located in Areas 2, 3, 5, and 18 of the Nevada Test Site: CAS 02-42-01, Condo Release Storage Yd - North; CAS 02-42-02, Condo Release Storage Yd - South; CAS 02-99-10, D-38 Storage Area; CAS 03-42-01, Conditional Release Storage Yard; CAS 05-19-02, Contaminated Soil and Drum; CAS 18-01-01, Aboveground Storage Tank; and CAS 18-99-03, Wax Piles/Oil Stain. Closure activities were conducted from March to July 2009 according to the FF ACO (1996, as amended February 2008) and the Corrective Action Plan for CAU 166 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2007b). The corrective action alternatives included No Further Action and Clean Closure. Closure activities are summarized. CAU 166, Storage Yards and Contaminated Materials, consists of seven CASs in Areas 2, 3, 5, and 18 of the NTS. The closure alternatives included No Further Action and Clean Closure. This CR provides a summary of completed closure activities, documentation of waste disposal, and confirmation that remediation goals were met. The following site closure activities were performed at CAU 166 as documented in this CR: (1) At CAS 02-99-10, D-38 Storage Area, approximately 40 gal of lead shot were removed and are currently pending treatment and disposal as MW, and approximately 50 small pieces of DU were removed and disposed as LLW. (2) At CAS 03-42-01, Conditional Release Storage Yard, approximately 7.5 yd{sup 3} of soil impacted with lead and Am-241 were removed and disposed as LLW. As a BMP, approximately 22 ft{sup 3} of asbestos tile were removed from a portable building and disposed as ALLW, approximately 55 gal of oil were drained from accumulators and are currently pending disposal as HW, the portable building was removed and

  6. Closure Report for Corrective Action Unit 166: Storage Yards and Contaminated Materials, Nevada Test Site, Nevada

    International Nuclear Information System (INIS)

    2009-01-01

    Corrective Action Unit (CAU) 166 is identified in the Federal Facility Agreement and Consent Order (FFACO) as 'Storage Yards and Contaminated Materials' and consists of the following seven Corrective Action Sites (CASs), located in Areas 2, 3, 5, and 18 of the Nevada Test Site: CAS 02-42-01, Condo Release Storage Yd - North; CAS 02-42-02, Condo Release Storage Yd - South; CAS 02-99-10, D-38 Storage Area; CAS 03-42-01, Conditional Release Storage Yard; CAS 05-19-02, Contaminated Soil and Drum; CAS 18-01-01, Aboveground Storage Tank; and CAS 18-99-03, Wax Piles/Oil Stain. Closure activities were conducted from March to July 2009 according to the FF ACO (1996, as amended February 2008) and the Corrective Action Plan for CAU 166 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office, 2007b). The corrective action alternatives included No Further Action and Clean Closure. Closure activities are summarized. CAU 166, Storage Yards and Contaminated Materials, consists of seven CASs in Areas 2, 3, 5, and 18 of the NTS. The closure alternatives included No Further Action and Clean Closure. This CR provides a summary of completed closure activities, documentation of waste disposal, and confirmation that remediation goals were met. The following site closure activities were performed at CAU 166 as documented in this CR: (1) At CAS 02-99-10, D-38 Storage Area, approximately 40 gal of lead shot were removed and are currently pending treatment and disposal as MW, and approximately 50 small pieces of DU were removed and disposed as LLW. (2) At CAS 03-42-01, Conditional Release Storage Yard, approximately 7.5 yd 3 of soil impacted with lead and Am-241 were removed and disposed as LLW. As a BMP, approximately 22 ft 3 of asbestos tile were removed from a portable building and disposed as ALLW, approximately 55 gal of oil were drained from accumulators and are currently pending disposal as HW, the portable building was removed and disposed as LLW, and

  7. Detection of water-quality contamination events based on multi-sensor fusion using an extented Dempster–Shafer method

    International Nuclear Information System (INIS)

    Hou, Dibo; He, Huimei; Huang, Pingjie; Zhang, Guangxin; Loaiciga, Hugo

    2013-01-01

    This study presents a method for detecting contamination events of sources of drinking water based on the Dempster–Shafer (D-S) evidence theory. The detection method has the purpose of protecting water supply systems against accidental and intentional contamination events. This purpose is achieved by first predicting future water-quality parameters using an autoregressive (AR) model. The AR model predicts future water-quality parameters using recent measurements of these parameters made with automated (on-line) water-quality sensors. Next, a probabilistic method assigns probabilities to the time series of residuals formed by comparing predicted water-quality parameters with threshold values. Finally, the D-S fusion method searches for anomalous probabilities of the residuals and uses the result of that search to determine whether the current water quality is normal (that is, free of pollution) or contaminated. The D-S fusion method is extended and improved in this paper by weighted averaging of water-contamination evidence and by the analysis of the persistence of anomalous probabilities of water-quality parameters. The extended D-S fusion method makes determinations that have a high probability of being correct concerning whether or not a source of drinking water has been contaminated. This paper's method for detecting water-contamination events was tested with water-quality time series from automated (on-line) water quality sensors. In addition, a small-scale, experimental, water-pipe network was tested to detect water-contamination events. The two tests demonstrated that the extended D-S fusion method achieves a low false alarm rate and high probabilities of detecting water contamination events. (paper)

  8. A Study on Foodborne Bacterial Cross-contamination During Fresh Chicken Preparation

    Directory of Open Access Journals (Sweden)

    Shamma Ebrahim AlZaabi

    2017-12-01

    Full Text Available Background: Cross-contamination of foodborne pathogens from undercooked poultry meat to ready-to-eat food has been shown to be responsible for a number of foodborne disease outbreaks. Various studies have indicated that bacterial cross-contamination occurs during food preparation where bacteria present on food contact other surfaces and cause illness. Objectives: This study evaluated the ability of bacteria to survive and cross-contaminate other foods during the preparation of fresh chicken. Salmonella spp. cross-contamination from chicken to cucumber and utensils under various food handling scenarios was determined. Methods: Two scenarios were tested: in scenario 1, cutting board and knife used for cutting chicken without washing step were sampled. In scenario 2, cutting board and knife was washed with tap water separately after cutting chicken, and subsequently used for cutting cucumber. In scenario 1, chicken, cutting board, knife, and hands were sampled, and in scenario 2, cucumber was tested. Fluorescent in situ hybridization (FISH method, using published Salmonella specific gene probes was used for Salmonella detection in samples taken from cross-contamination scenarios. A culture-based detection by Hektoen enteric agar was used for the confirmation of Salmonella species. Results: All the samples analyzed were found to be positive for Salmonella spp. with different contamination levels. These results were further confirmed by culture based method. In scenario 1, Salmonella spp. was detected by Sal-1 and Salm-63 oligonucleotide probes in all four samples (chicken, cutting board, knife and hands. A high contamination level was observed in chicken samples in comparison to samples collected from cutting board, knife and hands. In scenario 2, Salmonella spp. was detected by Sal-1 and Salm-63 oligonucleotide probes in the cucumber with very low contamination level. Salmonella Enterica was also detected by Sal-3 and Sapath-3 in both scenarios but

  9. Sequestration Coating Performance Requirements for Mitigation of Contamination from a Radiological Dispersion Device

    International Nuclear Information System (INIS)

    Drake, J.

    2009-01-01

    Immediate action would be necessary to minimize the effects of a radiological 'dirty bomb' detonation in a major city. After a dirty bomb has been detonated, vehicular and pedestrian traffic, as well as weather effects, would increase the spread of loose contamination, making control and recovery more difficult and costly. While contaminant migration and chemical binding into surface materials can be relatively rapid, the immediate treatment of surfaces with large quantities of an appropriate compound could alleviate much of the difficulty in decontamination. The EPA's National Homeland Security Research Center (NHSRC), in collaboration with ASTM International, is currently developing performance standards for materials which could be applied to exterior surfaces contaminated by an RDD to mitigate the spread and migration of radioactive contamination. These performance standards are being promulgated via an ASTM Standard Specification to be published by ASTM International. Test methods will be developed to determine if candidate coatings meet the performance requirements stipulated in the ASTM performance standard. These test methods will be adapted from existing standard methods, or will be devised through laboratory research. The final set of test methods will be codified in an ASTM or other standard test method. The principal market for products described in the ASTM performance standard would be federal, state and local government emergency responders and response planners, decontamination service providers and those whose interests include protection and recovery of real estate potentially at risk from radiological terrorism. (authors)

  10. Re-thinking stressor interactions: The role of groundwater contamination impacting stream ecosystems

    DEFF Research Database (Denmark)

    McKnight, Ursula S.; Sonne, Anne Thobo; Rønde, Vinni Kampman

    ) to quantify the contaminant discharges, and potentially link the chemical impact and stream water quality. Potential pollution sources include two contaminated sites (Grindstedfactory/landfill), aquaculture, waste water discharges, and diffuse sources from agriculture and urban areas. Datafor xenobiotic...... chronic stress level, so even small perturbations on top of changes in water flow or additional chemical stressors may be detrimental to the stream health. To address this issue, we identified contaminant sources and chemical stressors along a 16-km groundwater-fedstream stretch (Grindsted, Denmark...... organic groundwater contaminants, pesticides, heavy metals, general water chemistry, physical conditions and stream flow from three campaigns in 2012 and 2014 were assessed. The measured chemicalconcentrations were converted to toxic units (TU) based on 48-h acute toxicity tests with Daphnia magna...

  11. Multisite Direct Determination of the Potential for Environmental Contamination of Urine Samples Used for Diagnosis of Sexually Transmitted Infections.

    Science.gov (United States)

    Andersson, Patiyan; Tong, Steven Y C; Lilliebridge, Rachael A; Brenner, Nicole C; Martin, Louise M; Spencer, Emma; Delima, Jennifer; Singh, Gurmeet; McCann, Frances; Hudson, Carolyn; Johns, Tracy; Giffard, Philip M

    2014-09-01

    The detection of a sexually transmitted infection (STI) agent in a urine specimen from a young child is regarded as an indicator of sexual contact. False positives may conceivably arise from the transfer of environmental contaminants in clinic toilet or bathroom facilities into urine specimens. The potential for contamination of urine specimens with environmental STI nucleic acid was tested empirically in the male and female toilets or bathrooms at 10 Northern Territory (Australia) clinics, on 7 separate occasions at each. At each of the 140 experiments, environmental contamination with Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis nucleic acid contamination was determined by swabbing 10 locations, and urine collection was simulated 5 times, using a (1) synthetic urine surrogate and (2) a standardized finger contamination procedure. The most contaminated toilets and bathrooms were in remote Indigenous communities. No contamination was found in the Northern Territory Government Sexual Assault Referral Centre clinics, and intermediate levels of contamination were found in sexual health clinics and in clinics in regional urban centres. The frequency of surrogate urine sample contamination was low but non-zero. For example, 4 of 558 of the urine surrogate specimens from remote clinics were STI positive. This is by far the largest study addressing the potential environmental contamination of urine samples with STI agents. Positive STI tests arising from environmental contamination of urine specimens cannot be ruled out. The results emphasize that urine specimens from young children taken for STI testing should be obtained by trained staff in clean environments, and duplicate specimens should be obtained if possible. © The Author 2013. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society.

  12. Vertical cut-off walls for the containment of contaminated ground

    International Nuclear Information System (INIS)

    Jessberger, H.L.; Krubasik, K.; Beine, R.A.

    1997-01-01

    Vertical cut-off walls are widely used for the containment of contaminated sites, where a capping system is not sufficient for the protection of groundwater. Various types of cut-off walls are introduced and new developments are prescribed. Design and testing principles are outlined. Containment techniques are the appropriate measure for old landfills and abandoned industrial sites with contaminated ground and groundwater, too, since the shortage of financial resources in many countries classifies clean-up techniques as too cost intensive in most cases

  13. Radioactive Contamination of Agricultural Products in Poland

    International Nuclear Information System (INIS)

    Muszynski, W.; Grabowski, D.; Rubel, B.; Kurowski, W.; Swietochowska, J.; Smagala, G.

    2003-01-01

    Radiological contamination of the environment is caused by nuclear activities on the globe: nuclear weapon tests and the Chernobyl accident. The transfer of radionuclides to the organism via ingestion is one of the sources of doses obtained by people. To assess the doses received by humans the intake of isotopes with daily diet was defined. The concentration of radionuclides in foodstuffs was determined. The network of Service for Measurement of Radioactive Contamination systematically controls all kinds of important agricultural products such as milk, meat, vegetables, fruit, cereals and forest products: mushrooms, blueberries etc. Measurement stations involved in food monitoring act within Sanitary-Epidemiological Stations, Veterinary Hygiene Units and Chemical-Agricultural Stations. All activities are co-ordinated by the Central Laboratory for Radiological Protection. The level of activity of caesium isotopes has regularly been monitored in collected samples originating from different administrative districts of Poland. Since 1994 the 134 Cs concentration has been below the detection limit. The activity of 137 Cs has been measured to determine long-term effect of the accident on the contamination of milk, meat and other foodstuffs. (orig.)

  14. Light contamination

    International Nuclear Information System (INIS)

    Cepeda Pena, William Enrique

    1998-01-01

    The article tries on the wrong use of the artificial light, of the main problems of the light contamination, dispersion of the light, noxious effects of the light contamination, ecological effects, effects on the man's biological rhythm, economic effects and effects about the civic and vial security, among other topics

  15. Treatment of Gravel Contaminated with Naturally Occurring Radioactive Element

    International Nuclear Information System (INIS)

    Sohsah, M. A.; Kamal, S. M.; Mamoon, A.

    2004-01-01

    Environmental protection primarily means controlling the releases of radioactive and non-radioactive wastes to the environment and involves treatment, storage, cleanup and disposal of these wastes. The present study concerns the cleanup of gravel that has been contaminated with 2 26 R a. Aqueous solutions of different compositions including water and various concentrations of calcium chloride and barium chloride were used to leach the contaminated gravel. The leaching experiments were carried out in glass column. In some leaching experiments, samples of sandy soil were placed below the gravel to test the sorption of the leached 2 26 R a by the soil. The relative efficiencies of the leachant and the extent of sorption of the leached radionuclide were determined both by the liquid scintillation counting and by the thermoluminescent chips. The TLD chips record the dose before and after decontamination of the gravel and before and after contamination of the soil samples when used. The results obtained indicated that acidified barium chloride was relatively the most effective leachant of 2 26 R a contamination. It reduced the dose from the contaminated gravel to almost half. The soil sample used adsorbs the leached radionuclides efficiently, increasing the soil naturally low dose to about six folds

  16. Direct current contamination of kilohertz frequency alternating current waveforms.

    Science.gov (United States)

    Franke, Manfred; Bhadra, Niloy; Bhadra, Narendra; Kilgore, Kevin

    2014-07-30

    Kilohertz frequency alternating current (KHFAC) waveforms are being evaluated in a variety of physiological settings because of their potential to modulate neural activity uniquely when compared to frequencies in the sub-kilohertz range. However, the use of waveforms in this frequency range presents some unique challenges regarding the generator output. In this study we explored the possibility of undesirable contamination of the KHFAC waveforms by direct current (DC). We evaluated current- and voltage-controlled KHFAC waveform generators in configurations that included a capacitive coupling between generator and electrode, a resistive coupling and combinations of capacitive with inductive coupling. Our results demonstrate that both voltage- and current-controlled signal generators can unintentionally add DC-contamination to a KHFAC signal, and that capacitive coupling is not always sufficient to eliminate this contamination. We furthermore demonstrated that high value inductors, placed in parallel with the electrode, can be effective in eliminating DC-contamination irrespective of the type of stimulator, reducing the DC contamination to less than 1 μA. This study highlights the importance of carefully designing the electronic setup used in KHFAC studies and suggests specific testing that should be performed and reported in all studies that assess the neural response to KHFAC waveforms. Published by Elsevier B.V.

  17. Acute toxicity assessment of explosive-contaminated soil extracting solution by luminescent bacteria assays.

    Science.gov (United States)

    Xu, Wenjie; Jiang, Zhenming; Zhao, Quanlin; Zhang, Zhenzhong; Su, Hongping; Gao, Xuewen; Ye, Zhengfang

    2016-11-01

    Explosive-contaminated soil is harmful to people's health and the local ecosystem. The acute toxicity of its extracting solution was tested by bacterial luminescence assay using three kinds of luminescent bacteria to characterize the toxicity of the soil. An orthogonal test L 16 (4 5 ) was designed to optimize the soil extracting conditions. The optimum extracting conditions were obtained when the ultrasonic extraction time, ultrasonic extraction temperature, and the extraction repeat times were 6 h, 40 °C, and three, respectively. Fourier transform infrared spectroscopy (FTIR) results showed that the main components of the contaminated soil's extracting solution were 2,4-dinitrotoluene-3-sulfonate (2,4-DNT-3-SO 3 - ); 2,4-dinitrotoluene-5-sulfonate (2,4-DNT-5-SO 3 - ); and 2,6-dinitrotoluene (2,6-DNT). Compared with Photobacterium phosphoreum and Vibrio fischeri, Vibrio qinghaiensis sp. Nov. is more suitable for assessing the soil extracting solution's acute toxicity. Soil washing can remove most of the contaminants toxic to luminescent bacterium Vibrio qinghaiensis sp. Nov., suggesting that it may be a potential effective remediation method for explosive-contaminated soil.

  18. Current Measures on Radioactive Contamination in Japan: A Policy Situation Analysis.

    Directory of Open Access Journals (Sweden)

    Stuart Gilmour

    areas at risk of radioactive contamination. Monitoring of radioactive materials in food products in the prefectures has been mainly conducted before shipment to restrict the distribution of radio-contaminated foods. Between March 2011 and March 2012, 133,832 tests of non-commercial and commercial products were conducted, and 1,204 tests (0.9% were found to violate the provisional standards. Since April 2012, 278,275 tests were conducted, and 2,372 tests (0.9% were found to violate the revised standards. MHLW assessment of representative market baskets of foodstuffs at 15 locations throughout Japan between February and March 2014 found very low estimated dietary intake of radioactive cesium (0.0007-0.019 mSv/year, as did assessments of the contents of an average day's food. Monitoring of fisheries products in coastal areas affected by the nuclear accident found very limited and declining radio-contamination of live fish outside of Fukushima prefecture. Fisheries monitoring is of limited geographical scope and covers only certain fishes.Area-specific bans on production and distribution have been effective in preventing radioactive contamination in the Japanese food market. Currently there is no major concern about radioactive cesium concentrations in retail foodstuffs in Japan, and very low levels of contamination at the production and wholesale stage. However, because the residue limits and food safety policies were revised on an ad hoc, emergency basis after the nuclear accident, the monitoring procedure needs to be reviewed based on objective and scientifically rational criteria. A transparent and objective scientific framework is needed for prioritizing foodstuffs for inspection and revising Prefecture-specific restrictions. Monitoring of fishes and other seafood products in the wild should be regularized and the information made more publicly accessible, and monitoring activities expanded to identify foodstuffs that are no longer a food safety risk. Consultation with

  19. Bacterial Hand Contamination and Transfer after Use of Contaminated Bulk-Soap-Refillable Dispensers▿†

    OpenAIRE

    Zapka, Carrie A.; Campbell, Esther J.; Maxwell, Sheri L.; Gerba, Charles P.; Dolan, Michael J.; Arbogast, James W.; Macinga, David R.

    2011-01-01

    Bulk-soap-refillable dispensers are prone to extrinsic bacterial contamination, and recent studies demonstrated that approximately one in four dispensers in public restrooms are contaminated. The purpose of this study was to quantify bacterial hand contamination and transfer after use of contaminated soap under controlled laboratory and in-use conditions in a community setting. Under laboratory conditions using liquid soap experimentally contaminated with 7.51 log10 CFU/ml of Serratia marcesc...

  20. Skin decontamination cream for radiological contaminants: Formulation development and evaluation.

    Science.gov (United States)

    Khan, Abdul Wadood; Kotta, Sabna; Rana, Sudha; Ansari, Shahid Husain; Sharma, Rakesh Kumar; Ali, Javed

    2013-01-01

    Increased use of the radioactive materials in the field of research, medical, nuclear power plant, and industry has increased the risk of accidental exposure. Intentional use of the radioisotopes by terrorist organizations could cause exposure/contamination of a number of the population. In view of the accidental contamination, there is a need to develop self-usable decontamination formulations that could be used immediately after contamination is suspected. Present work was planned to optimize and develop self-usable radiation decontamination cream formulation. Various pharmaceutical parameters were characterized. (99m)Tc-sodium pertechnetate was used as radiocontaminant. Static counts were recorded before and after decontamination using single photon emission computed tomography. Decontamination efficacy of the cream was found to be 42% ± 3% at 0-0.5 h after the exposure. Primary skin irritancy test was satisfactory as no erythema or edema was observed visually after 2 weeks of the formulation application. The decontamination studies proved the potential of EDTA to remove the radiological contaminants effectively.