WorldWideScience

Sample records for contacts ii analysis

  1. On contact modelling in isogeometric analysis

    Science.gov (United States)

    Cardoso, R. P. R.; Adetoro, O. B.

    2017-11-01

    IsoGeometric Analysis (IGA) has proved to be a reliable numerical tool for the simulation of structural behaviour and fluid mechanics. The main reasons for this popularity are essentially due to: (i) the possibility of using higher order polynomials for the basis functions; (ii) the high convergence rates possible to achieve; (iii) the possibility to operate directly on CAD geometry without the need to resort to a mesh of elements. The major drawback of IGA is the non-interpolatory characteristic of the basis functions, which adds a difficulty in handling essential boundary conditions and makes it particularly challenging for contact analysis. In this work, the IGA is expanded to include frictionless contact procedures for sheet metal forming analyses. Non-Uniform Rational B-Splines (NURBS) are going to be used for the modelling of rigid tools as well as for the modelling of the deformable blank sheet. The contact methods developed are based on a two-step contact search scheme, where during the first step a global search algorithm is used for the allocation of contact knots into potential contact faces and a second (local) contact search scheme where point inversion techniques are used for the calculation of the contact penetration gap. For completeness, elastoplastic procedures are also included for a proper description of the entire IGA of sheet metal forming processes.

  2. Clinical evaluation of the Non-Contact Tonometer Mark II.

    Science.gov (United States)

    Chauhan, B C; Henson, D B

    1988-09-01

    The purpose of this investigation was to test the reliability of the American Optical Non-Contact Tonometer Mark II (NCT II) using the Goldmann Applanation Tonometer (GAT) as the validating instrument. The sample contained 102 consecutive patients from our University Eye Clinic, of whom one-half had 4 NCT II measurements first, followed by 4 GAT measurements; the other one-half had 4 GAT measurements first, followed by 4 NCT II measurements. No significant change in intraocular pressure (IOP) was noted over the measurement sequence with either instrument. There was no significant difference between paired NCT II and GAT readings when the NCT II was used first; however, a highly significant difference between paired readings was obtained when the GAT was used first, indicating that the GAT measurement produced a delayed reduction in the IOP. This effect did not occur with the NCT II. Although the NCT II is shown to have a good overall reliability when compared to the GAT in both protocols, the agreement between any two tonometers may be influenced greatly by the very process of taking a measurement and by the dynamic nature of the IOP.

  3. Unified Analysis of Multi-Chamber Contact Tanks and Mixing Efficiency Evaluation Based on Vorticity Field. Part II: Transport Analysis

    Directory of Open Access Journals (Sweden)

    Ender Demirel

    2016-11-01

    Full Text Available Mixing characteristics of multi-chambered contact tank are analyzed employing the validated three-dimensional numerical model developed in the companion paper. Based on the flow characterization, novel volumetric mixing efficiency definitions are proposed for the assessment of the hydrodynamic and chemical transport properties of the contact tank and its chambers. Residence time distribution functions are analyzed not only at the outlet of each chamber but also inside the chambers using the efficiency definitions for both Reynolds averaged Navier–Stokes (RANS and large eddy simulation (LES results. A novel tracer mixing index is defined to characterize short circuiting and mixing effects of the contact system. Comparisons of the results of these indexes for RANS and LES solutions indicate that mixing characteristics are stronger in LES due to the unsteady turbulent eddy mixing even though short circuiting effects are also more prominent in LES results. This result indicates that the mixing analysis based on the LES results simulates the mixing characteristics instantaneously, which is more realistic than that in RANS. Since LES analysis can capture turbulent eddy mixing better than RANS analysis, the interaction of recirculation and jet zones are captured more effectively in LES, which tends to predict higher turbulent mixing in the contact system. The analysis also shows that the mixing efficiency of each chamber of the contact tank is different, thus it is necessary to consider distinct chemical release and volumetric designs for each chamber in order to maximize the mixing efficiency of the overall process in a contact tank system.

  4. Concomitant contact allergies to formaldehyde, methylchloroisothiazolinone/methylisothiazolinone, methylisothiazolinone, and fragrance mixes I and II.

    Science.gov (United States)

    Pontén, Ann; Bruze, Magnus; Engfeldt, Malin; Hauksson, Inese; Isaksson, Marléne

    2016-11-01

    Contact allergies to the preservatives formaldehyde and methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI) have been reported to appear together at a statistically significant level. Recently, revisions concerning the patch test preparations of MCI/MI, MI and formaldehyde have been recommended for the European baseline series. To investigate (i) the number of concomitant contact allergies to the preservatives, (ii) the number of concomitant contact allergies to the preservatives and the fragrance mixes (FM I and FM II) and (iii) gender differences. Patients tested with the Swedish baseline series during the period 2012-2014 at the Department of Occupational and Environmental Dermatology in Malmö, Sweden were investigated. 2165 patients were patch tested with the baseline series (34% males and 66% females). Contact allergies to formaldehyde and MCI/MI and/or MI were significantly associated (p fragrance allergy. Males and females do not differ significantly concerning contact allergy to fragrances. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Safety analysis report for the TRUPACT-II shipping package (condensed version). Volume 1, Rev. 14

    International Nuclear Information System (INIS)

    1994-10-01

    The condensed version of the TRUPACT-II Contact Handled Transuranic Waste Safety Analysis Report for Packaging (SARP) contains essential material required by TRUPACT-II users, plus additional contents (payload) information previously submitted to the U.S. Nuclear Regulatory Commission. All or part of the following sections, which are not required by users of the TRUPACT-II, are deleted from the condensed version: (i) structural analysis, (ii) thermal analysis, (iii) containment analysis, (iv) criticality analysis, (v) shielding analysis, and (vi) hypothetical accident test results

  6. Safety analysis report for the TRUPACT-II shipping package (condensed version). Volume 1, Rev. 14

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-10-01

    The condensed version of the TRUPACT-II Contact Handled Transuranic Waste Safety Analysis Report for Packaging (SARP) contains essential material required by TRUPACT-II users, plus additional contents (payload) information previously submitted to the U.S. Nuclear Regulatory Commission. All or part of the following sections, which are not required by users of the TRUPACT-II, are deleted from the condensed version: (i) structural analysis, (ii) thermal analysis, (iii) containment analysis, (iv) criticality analysis, (v) shielding analysis, and (vi) hypothetical accident test results.

  7. Evaluation of proximal contact tightness of Class II resin composite restorations.

    NARCIS (Netherlands)

    Saber, M.H.; Loomans, B.A.C.; Zohairy, A. El; Dorfer, C.E.; El-Badrawy, W.

    2010-01-01

    OBJECTIVE: The objective of the current study was to compare in-vitro the proximal contact tightness (PCT) of Class II resin composite restorations (RCR) placed with different established and new placement techniques. METHODS: 105 ivorine lower left first molars with standardized MO cavities were

  8. [Sport injuries in full contact and semi-contact karate].

    Science.gov (United States)

    Greier, K; Riechelmann, H; Ziemska, J

    2014-03-01

    Karate enjoys great popularity both in professional and recreational sports and can be classified into full, half and low contact styles. The aim of this study was the analysis of sports injuries in Kyokushinkai (full contact) and traditional Karate (semi-contact). In a retrospective study design, 215 active amateur karateka (114 full contact, 101 semi-contact) were interviewed by means of a standardised questionnaire regarding typical sport injuries during the last 36 months. Injuries were categorised into severity grade I (not requiring medical treatment), grade II (single medical treatment), grade III (several outpatient medical treatments) and grade IV (requiring hospitalisation). In total, 217 injuries were reported in detail. 125 injuries (58%) occurred in full contact and 92 (42%) in semi-contact karate. The time related injury rate of full contact karateka was 1.9/1000 h compared to 1.3/1000 h of semi-contact karateka (p injuries were musculoskeletal contusions (33% full contact, 20% semi-contact), followed by articular sprains with 19% and 16%. The lower extremity was affected twice as often in full contact (40%) as in semi-contact (20%) karate. Training injuries were reported by 80% of the full contact and 77% of the semi-contact karateka. Most injuries, both in training and competition, occurred in kumite. 75% of the reported injuries of full contact and 70% of semi-contact karateka were classified as low grade (I or II). The high rate of injuries during training and kumite (sparring) points to specific prevention goals. The emphasis should be put on proprioceptive training and consistent warm-up. In the actual competition the referees play a vital role regarding prevention. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Large deformation contact mechanics of a pressurized long rectangular membrane. II. Adhesive contact

    Science.gov (United States)

    Srivastava, Abhishek; Hui, Chung-Yuen

    2013-01-01

    In part I of this work, we presented a theory for adhesionless contact of a pressurized neo-Hookean plane-strain membrane to a rigid substrate. Here, we extend our theory to include adhesion using a fracture mechanics approach. This theory is used to study contact hysteresis commonly observed in experiments. Detailed analysis is carried out to highlight the differences between frictionless and no-slip contact. Membrane detachment is found to be strongly dependent on adhesion: for low adhesion, the membrane ‘pinches-off’, whereas for large adhesions, it detaches unstably at finite contact (‘pull-off’). Expressions are derived for the critical adhesion needed for pinch-off to pull-off transition. Above a threshold adhesion, the membrane exhibits bistability, two stable states at zero applied pressure. The condition for bistability for both frictionless and no-slip boundary conditions is obtained explicitly. PMID:24353472

  10. Large-Area, Multi-Junction, Epitaxial Lift-Off Solar Cells with Backside Contacts, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II program we propose to develop a manufacturable production process to introduce backside contacts to MicroLink Devices? large-area, multi-junction...

  11. Contact mechanical analysis of O-ring stresses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Kyu

    2007-02-15

    The purpose of this project is to develop the approximate solutions of contact traction and internal stress of an O-ring by using a two dimensional elasticity for enhancing the design and failure prediction technology. Investigated were the applicability of Lindley's formulae of contact force prediction and the Hertz theory. Three cases of O-ring installation were considered. The approximate solution of contact tractions and internal stresses of each case were derived. The key results are summarized as follows: 1. It is verified that Lindley's formulae predicts the relationship between the fractional compression and contact force. 2. In the case of Case I, II and III without internal pressure, it is found that a function form of the contact traction is the Hertzian. So it is possible to express the traction with a Hertzian form and correction factors. 3. The internal stresses are derived in the case of the Hertzian traction profile. The stresses at the center of O-ring show a satisfactory result when compared with the finite element result.

  12. Applicability of contact angle techniques used in the analysis of contact lenses, part 1: comparative methodologies.

    Science.gov (United States)

    Campbell, Darren; Carnell, Sarah Maria; Eden, Russell John

    2013-05-01

    Contact angle, as a representative measure of surface wettability, is often employed to interpret contact lens surface properties. The literature is often contradictory and can lead to confusion. This literature review is part of a series regarding the analysis of hydrogel contact lenses using contact angle techniques. Here we present an overview of contact angle terminology, methodology, and analysis. Having discussed this background material, subsequent parts of the series will discuss the analysis of contact lens contact angles and evaluate differences in published laboratory results. The concepts of contact angle, wettability and wetting are presented as an introduction. Contact angle hysteresis is outlined and highlights the advantages in using dynamic analytical techniques over static methods. The surface free energy of a material illustrates how contact angle analysis is capable of providing supplementary surface characterization. Although single values are able to distinguish individual material differences, surface free energy and dynamic methods provide an improved understanding of material behavior. The frequently used sessile drop, captive bubble, and Wilhelmy plate techniques are discussed. Their use as both dynamic and static methods, along with the advantages and disadvantages of each technique, is explained. No single contact angle technique fully characterizes the wettability of a material surface, and the application of complimenting methods allows increased characterization. At present, there is not an ISO standard method designed for soft materials. It is important that each contact angle technique has a standard protocol, as small protocol differences between laboratories often contribute to a variety of published data that are not easily comparable.

  13. Contact lens wear by Royal Air Force aircrew in World War II.

    Science.gov (United States)

    Pearson, Richard M

    2014-04-01

    To provide an overview of the use of contact lenses by RAF aircrew in World War II by identifying some of the fitters and wearers and appraising the clinical results that they achieved. A wide-ranging literature search was undertaken that encompassed peer-reviewed journals, non-refereed publications, books, official publications, newspapers and archived documents. Thirty-one aircrew are known to have worn sealed scleral lenses in order to meet the required visual standards. Of these, only two were considered to be completely unsuccessful, one of whom was unilaterally aphakic. One additional case of undisclosed contact lens wear was found and the identity of this officer was established. Brief biographies of a few pilots establish the context of their contact lens wear. Overall, the results of scleral lens wear were variable reflecting those achieved by civilian patients of the period. While three men complained of discomfort due to heat and glare, one pilot experienced no photophobia when flying above white clouds in brilliant sunshine and another found no difficulty caused by altitude or tropical climate. Wearing time ranged from about 2h to 16, or more, hours. In about a third of the cases, wearing time was limited due to the onset of a form of contact lens induced-epithelial oedema known as Sattler's veil and effective solutions to this problem were not implemented until after the war. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  14. Analysis of Non-contact Acousto Thermal Signature Data (Postprint)

    Science.gov (United States)

    2016-02-01

    AFRL-RX-WP-JA-2016-0321 ANALYSIS OF NON-CONTACT ACOUSTO-THERMAL SIGNATURE DATA (POSTPRINT) Amanda K. Criner AFRL/RX...October 2014 – 16 September 2015 4. TITLE AND SUBTITLE ANALYSIS OF NON-CONTACT ACOUSTO-THERMAL SIGNATURE DATA (POSTPRINT) 5a. CONTRACT NUMBER...words) The non-contact acousto-thermal signature (NCATS) is a nondestructive evaluation technique with potential to detect fatigue in materials such as

  15. Graphical analysis of NMR structural quality and interactive contact map of NOE assignments in ARIA

    Directory of Open Access Journals (Sweden)

    Malliavin Thérèse E

    2008-06-01

    Full Text Available Abstract Background The Ambiguous Restraints for Iterative Assignment (ARIA approach is widely used for NMR structure determination. It is based on simultaneously calculating structures and assigning NOE through an iterative protocol. The final solution consists of a set of conformers and a list of most probable assignments for the input NOE peak list. Results ARIA was extended with a series of graphical tools to facilitate a detailed analysis of the intermediate and final results of the ARIA protocol. These additional features provide (i an interactive contact map, serving as a tool for the analysis of assignments, and (ii graphical representations of structure quality scores and restraint statistics. The interactive contact map between residues can be clicked to obtain information about the restraints and their contributions. Profiles of quality scores are plotted along the protein sequence, and contact maps provide information of the agreement with the data on a residue pair level. Conclusion The graphical tools and outputs described here significantly extend the validation and analysis possibilities of NOE assignments given by ARIA as well as the analysis of the quality of the final structure ensemble. These tools are included in the latest version of ARIA, which is available at http://aria.pasteur.fr. The Web site also contains an installation guide, a user manual and example calculations.

  16. Tibiofemoral contact stress and stress distribution evaluation of total knee arthroplasties.

    Science.gov (United States)

    Szivek, J A; Cutignola, L; Volz, R G

    1995-08-01

    The Fuji film (Itochu, Los Angeles, CA) area analysis technique demonstrates that a more accurate assessment of tibiofemoral contact stresses is possible when the film is used at 37 degrees C and at the upper end of its sensitivity range (in this case, a 2,000-N load). An AMK with a regular and Hylamer-M insert (DePuy, Warsaw, IN), an MG II (Zimmer, Warsaw, IN), an Omnifit (Osteonics, Allendale, NJ), an Ortholoc III (Dow Corning Wright, Midland, MI), a PCA II (Howmedica, Rutherford, NJ), and a PFC (Johnson & Johnson Orthopaedics, Raynham, MA) had average contact stresses that varied only 12% at 60 degrees flexion. At 0 degrees, 15 degrees and 60 degrees flexion, stresses ranged from 13 to 25 MPa. Contact area distribution ratios, which were smaller at 37 degrees C than at 24 degrees C, provide a quantitative means of grouping implants according to the shape of the tibiofemoral contact area. The Omnifit, MG II, PCA II, and PFC had small ratios (symmetric areas). The AMK and Ortholoc III had large ratios (asymmetric contact areas). If the impression is reflective of wear, it would be expected to be focal in knees with small ratios and contact areas, and uniform in knees with large ratios and contact areas, whereas large ratios and small areas would imply a linear wear pattern. Calibrated electrical resistance contact stress measurements indicated that the Fuji film measurements underestimated the magnitude of contact stresses. They also provided a means of quantifying the rate of area increase during initial loading of the knees, with the highest area increase noted for the knee with the roughest insert (Ortholoc III) and the lowest area increase for the knee with the smoothest insert (PCA II).

  17. Contact angle study on the activation mechanisms of sphalerite with Cu(II) and Pb(II); Estudio de los mecanismos de activacion de la esfalerita con Cu(II) y Pb(II)

    Energy Technology Data Exchange (ETDEWEB)

    Davila Pulido, G. I.; Uribe Salas, A.

    2011-07-01

    This article presents results of an experimental study on the sphalerite activation with Cu(II) and Pb(II), whose main objective was to investigate the activation mechanisms and to evaluate the magnitude of the hydrophobization achieved with both chemical species. The hydrophobicity acquired by the mineral due to the interaction with the activator and collector (sodium isopropyl xanthate) is characterized making use of the contact angle technique. The results show that Cu(II) replaces the Zn of the external layers of the mineral, promoting the sulfide (S{sup 2}-) oxidation to produce a mixture of CuS, Cu{sub 2}S and S{sup o}, of hydrophobic nature. The subsequent interaction with xanthate increases the hydrophobicity of the mineral surface. In turn, Pb(II) activation of sphalerite is due to the formation of a PbS layer that reacts with xanthate to produce hydrophobic species (e.g., PbX{sub 2}). It is also observed that the hydrophobicity of sphalerite activated with Pb(II) is favored under air atmospheres, as compared to that obtained under nitrogen atmospheres. It is concluded that the hydrophobicity achieved by lead activation may be of the same order of magnitude to that deliverately induced by copper activation. (Author) 11 refs.

  18. Preliminary design analysis of the ALT-II limiter for TEXTOR

    International Nuclear Information System (INIS)

    Koski, J.A.; Boyd, R.D.; Kempka, S.M.; Romig, A.D. Jr.; Smith, M.F.; Watson, R.D.; Whitley, J.B.; Conn, R.W.; Grotz, S.P.

    1984-01-01

    Installation of a large toroidal belt pump limiter, Advanced Limiter Test II (ALT-II), on the TEXTOR tokamak at Juelich, FRG is anticipated for early 1986. This paper discusses the preliminary mechanical design and materials considerations undertaken as part of the feasibility study phase for ALT-II. Since the actively cooled limiter blade is the component in direct contact with the plasma edge, and thus subject to the severe plasma environment, most preliminary design efforts have concentrated on analysis of the blade. The screening process which led to the recommended preliminary design consisting of a dispersion strenghthened copper or OFHC copper cover plate over an austenitic stainless steel base plate is discussed. A 1 to 3 mm thick low atomic number coating consisting of a graded plasma-sprayed Silicon Carbide-Aluminium composite is recommended subject to further experiment and evaluation. Thermal-hydraulic and stress analyses of the limiter blade are also discussed. (orig.)

  19. Discretization and numerical realization of contact problems for elastic-perfectly plastic bodies. PART II - numerical realization, limit analysis

    Czech Academy of Sciences Publication Activity Database

    Čermák, M.; Haslinger, Jaroslav; Kozubek, T.; Sysala, Stanislav

    2015-01-01

    Roč. 95, č. 12 (2015), s. 1348-1371 ISSN 0044-2267 R&D Projects: GA ČR GA13-18652S Institutional support: RVO:68145535 Keywords : frictionless contact * alternating direction method of multipliers * limit load analysis * elastic-perfect analplasticity Subject RIV: BA - General Mathematics Impact factor: 1.293, year: 2015 http://onlinelibrary.wiley.com/doi/10.1002/zamm.201400069/epdf

  20. Development of contact failure analysis technology - first year(2000) report -

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Kyu; Yoon, Kyung Ho; Kang, Heung Seok; Song, Kee Nam

    2001-01-01

    Contact tractions are affected by the geometry of contacting bodies. In the present research, square punch, wedge and cylinders are considered as the geometry. Among the geometry, a square punch with rounded corners is basically used. Normal traction profile is obtained in the case of the rounded punch, and shear tractions are evaluated under the partial slip regime by using the influence function method. Multiplication of the shear traction and slip displacement in the slip region of the contact provides the friction energy dissipation from the contact. Since the trace of the shear force influences the amount of the dissipated energy, a desirable trace of the shear force may be supposed to reduce the energy dissipation. Internal stresses are evaluated from the contact normal and shear tractions, which are to be used for calculating the stress intensity factors of a surface breaking crack emanated from the contact surface. The stress intensity factors, K{sub I} and K{sub II}, are investigated during the cyclic shear. It is found that a period of crack opening exists during a shear cycle, which is effective for crack growing. So, to reduce the period can be a method for restraining the cracking failure. On the other hand, there can exist a desirable shape of the contacting body, which can restrain the cracking failure. In the experiment, fretting wear tester is used with the specially designed specimen. Wear of the contact surface are observed in detail, which shows typical shape following the partial and gross slip regimes. An algorithm for evaluating the wear volume is newly developed using the signal processing technique and the Fast Fourier Transform (FFT)

  1. Development of contact failure analysis technology - first year(2000) report -

    International Nuclear Information System (INIS)

    Kim, Hyung Kyu; Yoon, Kyung Ho; Kang, Heung Seok; Song, Kee Nam

    2001-01-01

    Contact tractions are affected by the geometry of contacting bodies. In the present research, square punch, wedge and cylinders are considered as the geometry. Among the geometry, a square punch with rounded corners is basically used. Normal traction profile is obtained in the case of the rounded punch, and shear tractions are evaluated under the partial slip regime by using the influence function method. Multiplication of the shear traction and slip displacement in the slip region of the contact provides the friction energy dissipation from the contact. Since the trace of the shear force influences the amount of the dissipated energy, a desirable trace of the shear force may be supposed to reduce the energy dissipation. Internal stresses are evaluated from the contact normal and shear tractions, which are to be used for calculating the stress intensity factors of a surface breaking crack emanated from the contact surface. The stress intensity factors, K I and K II , are investigated during the cyclic shear. It is found that a period of crack opening exists during a shear cycle, which is effective for crack growing. So, to reduce the period can be a method for restraining the cracking failure. On the other hand, there can exist a desirable shape of the contacting body, which can restrain the cracking failure. In the experiment, fretting wear tester is used with the specially designed specimen. Wear of the contact surface are observed in detail, which shows typical shape following the partial and gross slip regimes. An algorithm for evaluating the wear volume is newly developed using the signal processing technique and the Fast Fourier Transform (FFT)

  2. Corrosion failure analysis of hearing aid battery-spring contacts

    DEFF Research Database (Denmark)

    Gudla, Visweswara Chakravarthy; Ambat, Rajan

    2017-01-01

    the susceptibility of these systems to galvanic corrosion. In this study, traditional behind the ear (BTE) hearing aid systems, which failed during service were analysed. Failure analysis was performed on the dome type battery-spring contact systems. The morphology of the contact areas was observed using scanning......Reliability of low power electrical contacts such as those in hearing aid battery-spring systems is a very critical aspect for the overall performance of the device. These systems are exposed to certain harsh environments like high humidity and elevated temperatures, and often in combination...... electron microscopy, and the compositional analysis of the corrosion products and contaminants was performed using energy dispersive X-ray spectroscopy. Wear track morphology was observed on the contact points, and the top coating on the dome was worn out exposing the substrate spring material...

  3. Performance Analysis of Functionally Graded Coatings in Contact with Cylindrical Rollers

    Directory of Open Access Journals (Sweden)

    Reza Jahedi

    2015-01-01

    Full Text Available This work presents finite element analysis (FEA and results for rolling contact of a cylindrical roller on an elastic substrate coated by functionally graded material (FGM. The rolling process and the graded coating material property and layers arrangement are modeled using finite element codes which lead to a new methodology. This novel methodology provides a trend in determining surface contact stresses, deformations, contact zones, and energy dissipation through the contact area. Effects of stiffness ratio, friction, and exponentially variation of material property on the contact stresses and deformations are studied. Some of the results are verified with analytical solutions. The study results may be beneficial in graded coated cylindrical components analysis against rolling contact failure and wear.

  4. Refining intra-protein contact prediction by graph analysis

    Directory of Open Access Journals (Sweden)

    Eyal Eran

    2007-05-01

    Full Text Available Abstract Background Accurate prediction of intra-protein residue contacts from sequence information will allow the prediction of protein structures. Basic predictions of such specific contacts can be further refined by jointly analyzing predicted contacts, and by adding information on the relative positions of contacts in the protein primary sequence. Results We introduce a method for graph analysis refinement of intra-protein contacts, termed GARP. Our previously presented intra-contact prediction method by means of pair-to-pair substitution matrix (P2PConPred was used to test the GARP method. In our approach, the top contact predictions obtained by a basic prediction method were used as edges to create a weighted graph. The edges were scored by a mutual clustering coefficient that identifies highly connected graph regions, and by the density of edges between the sequence regions of the edge nodes. A test set of 57 proteins with known structures was used to determine contacts. GARP improves the accuracy of the P2PConPred basic prediction method in whole proteins from 12% to 18%. Conclusion Using a simple approach we increased the contact prediction accuracy of a basic method by 1.5 times. Our graph approach is simple to implement, can be used with various basic prediction methods, and can provide input for further downstream analyses.

  5. Biosorption of Cd(II) and Zn(II) by nostoc commune: isotherm and kinetics studies

    Energy Technology Data Exchange (ETDEWEB)

    Morsy, Fatthy M. [Faculty of Science, Botany Department, Assiut University, Assiut (Egypt); Hassan, Sedky H.A. [Department of Biological Environment, Kangwon National University, Kangwon-do (Korea, Republic of); Koutb, Mostafa [Faculty of Science, Botany Department, Assiut University, Assiut (Egypt); Umm Al-Qura University, Faculty of Applied Science, Biology Department, Mecca (Saudi Arabia)

    2011-07-15

    In this study, Nostoc commune (cyanobacterium) was used as an inexpensive and efficient biosorbent for Cd(II) and Zn(II) removal from aqueous solutions. The effect of various physicochemical factors on Cd(II) and Zn(II) biosorption such as pH 2.0-7.0, initial metal concentration 0.0-300 mg/L and contact time 0-120 min were studied. Optimum pH for removal of Cd(II) and Zn(II) was 6.0, while the contact time was 30 min at room temperature. The nature of biosorbent and metal ion interaction was evaluated by infrared (IR) technique. IR analysis of bacterial biomass revealed the presence of amino, carboxyl, hydroxyl, and carbonyl groups, which are responsible for biosorption of Cd(II) and Zn (II). The maximum biosorption capacities for Cd(II) and Zn(II) biosorption by N. commune calculated from Langmuir biosorption isotherm were 126.32 and 115.41 mg/g, respectively. The biosorption isotherm for two biosorbents fitted well with Freundlich isotherm than Langmuir model with correlation coefficient (r{sup 2} < 0.99). The biosorption kinetic data were fitted well with the pseudo-second-order kinetic model. Thus, this study indicated that the N. commune is an efficient biosorbent for the removal of Cd(II) and Zn(II) from aqueous solutions. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  6. Influence of the degree of thermal contact in fin and tube heat exchanger

    DEFF Research Database (Denmark)

    Singh, Shobhana; Sørensen, Kim; Condra, Thomas Joseph

    2016-01-01

    Present work aims to investigate the significance of thermal contact area between fins and tubes in a heat exchanger. The heat exchanger type selected for the study is a liquid-gas fin and tube heat exchanger. Four different cases namely I, II, III, and IV, based on a variable degree of thermal...... contact between fins and tubes are investigated. Case-I with 100% thermal contact area between the fin and tube is set as a reference to cases-II, III, and IV with a thermal contact area of approximately 70%, 50%, and 35%, respectively. Three-dimensional (3D) steady-state numerical models based on finite...... and to compare the performance of heat exchanger design in different cases. Comparative analysis indicates a significant influence of the degree of the thermal contact area between fin and tube on the overall performance. Case-I is found to have higher overall heat transfer coefficient of 47.332 W/(m2 K), higher...

  7. Contact and Non-contact Measurements of Grinding Pins

    Directory of Open Access Journals (Sweden)

    Magdziak Marek

    2015-01-01

    Full Text Available The paper presents the results of contact and non-contact measurements of external profiles of selected grinding pins. The measurements were conducted in order to choose the appropriate measuring technique in the case of the considered measurement task. In the case of contact measurements the coordinate measuring machine ACCURA II was applied. The used coordinate measuring machine was equipped with the contact scanning probe VAST XT and the Calypso inspection software. Contact coordinate measurements were performed by using of different measurement strategies. The applied strategies included different scanning velocities and distances between measured points. Non-contact measurements were conducted by means of the tool presetter produced by the Mahr company. On the basis of gained results the guidelines concerning measurements of grinding pins were formulated. The measurements of analyzed grinding pins performed by means of the non-contact measuring system are characterized by higher reproducibility than the contact measurements. The low reproducibility of contact measurements may be connected with the inaccuracy of the selected coordinate measuring machine and the measuring probe, the measurement parameters and environmental conditions in the laboratory where the coordinate measuring machine is located. Moreover, the paper presents the possible application of results of conducted investigations. The results of non-contact measurements can be used in the simulation studies of grinding processes. The simulations may reduce the costs of machining processes.

  8. Application of photogrammetry for analysis of occlusal contacts.

    Science.gov (United States)

    Shigeta, Yuko; Hirabayashi, Rio; Ikawa, Tomoko; Kihara, Takuya; Ando, Eriko; Hirai, Shinya; Fukushima, Shunji; Ogawa, Takumi

    2013-04-01

    The conventional 2D-analysis methods for occlusal contacts provided limited information on tooth morphology. This present study aims to detect 3D positional information of occlusal contacts from 2D-photos via photogrammetry. We propose an image processing solution for analysis of occlusal contacts and facets via the black silicone method and a photogrammetric technique. The occlusal facets were reconstructed from a 2D-photograph data-set of inter-occlusal records into a 3D image via photogrammetry. The configuration of the occlusal surface was reproduced with polygons. In addition, the textures of the occlusal contacts were mapped to each polygon. DIFFERENCE FROM CONVENTIONAL METHODS: Constructing occlusal facets with 3D polygons from 2D-photos with photogrammetry was a defining characteristic of this image processing technique. It allowed us to better observe findings of the black silicone method. Compared with conventional 3D analysis using a 3D scanner, our 3D models did not reproduce the detail of the anatomical configuration. However, by merging the findings of the inter-occlusal record, the deformation of mandible and the displacement of periodontal ligaments under occlusal force were reflected in our model. EFFECT OR PERFORMANCE: Through the use of polygons in the conversion of 2D images to 3D images, we were able to define the relation between the location and direction of the occlusal contacts and facets, which was difficult to detect via conventional methods. Through our method of making a 3D polygon model, the findings of inter-occlusal records which reflected the jaw/teeth behavior under occlusal force could be observed 3-dimensionally. Copyright © 2012 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  9. Characterizing protein conformations by correlation analysis of coarse-grained contact matrices

    Science.gov (United States)

    Lindsay, Richard J.; Siess, Jan; Lohry, David P.; McGee, Trevor S.; Ritchie, Jordan S.; Johnson, Quentin R.; Shen, Tongye

    2018-01-01

    We have developed a method to capture the essential conformational dynamics of folded biopolymers using statistical analysis of coarse-grained segment-segment contacts. Previously, the residue-residue contact analysis of simulation trajectories was successfully applied to the detection of conformational switching motions in biomolecular complexes. However, the application to large protein systems (larger than 1000 amino acid residues) is challenging using the description of residue contacts. Also, the residue-based method cannot be used to compare proteins with different sequences. To expand the scope of the method, we have tested several coarse-graining schemes that group a collection of consecutive residues into a segment. The definition of these segments may be derived from structural and sequence information, while the interaction strength of the coarse-grained segment-segment contacts is a function of the residue-residue contacts. We then perform covariance calculations on these coarse-grained contact matrices. We monitored how well the principal components of the contact matrices is preserved using various rendering functions. The new method was demonstrated to assist the reduction of the degrees of freedom for describing the conformation space, and it potentially allows for the analysis of a system that is approximately tenfold larger compared with the corresponding residue contact-based method. This method can also render a family of similar proteins into the same conformational space, and thus can be used to compare the structures of proteins with different sequences.

  10. Contact traction analysis for profile change during coining process

    International Nuclear Information System (INIS)

    Kim, Hyung Kyu; Yoon, Kyung Ho; Kang, Heung Seok; Song, Kee Nam

    2002-01-01

    Contact tractions are analysed in the case of the change in contact profile occurring during the coining process of a thin strip material. The changed profile is assumed as a concave circular arc in the central part of the contact region which is smoothly connected with convex circular arcs at both sides, referring to the actual measurement of the coined material. The profile is discretized and the known solutions of singular integral equations are used. Since the contact profile affects the contact traction and relevant tribological behaviour (e.g. wear) as well, an accurate definition of the profile is necessary in the analysis of material failure. Parametric study is conducted with the variation of the radii and distance of the arcs, which defines the height difference between the summits of the arcs. Considered is the contact profile, which can give the negligible variation of the traction in comparison with that before the coining process

  11. Descriptive analysis of the type and design of contact lenses fitted according to keratoconus severity and morphology

    Directory of Open Access Journals (Sweden)

    Letícia Helena Lunardi

    2016-04-01

    Full Text Available ABSTRACT Purpose: Keratoconus is characterized by bilateral asymmetrical corneal ectasia that leads to inferior stromal thinning and corneal protrusion. There is currently a lack of consensus regarding the most efficacious method for fitting contact lenses in patients with keratoconus, given the various topographical patterns and evolution grades observed in affected populations. The purpose of the present study was to evaluate the association between keratoconus evolution grade and topography pattern and the type and design of fitted contact lens. Methods: We performed a retrospective analysis of contact lenses fitted in a total of 185 patients with keratoconus (325 eyes. Keratoconus was classified as either grade I, II, III, or IV based on keratometry and cone morphology (nipple, oval, globus, or indeterminate results. Results: A total of 325 eyes were evaluated in the present study. Of the 62 eyes classified as grade I, 66.1% were fitted with monocurve contact lenses. Of the 162 eyes classified as grade I and II, 51%, 30%, and 19% were fitted with adapted monocurve rigid gas-permeable contact lenses (RGPCL, bicurve lenses, and others lens types, respectively. Bicurve lenses were fitted in 52.1% and 62.2% of eyes classified as grade III and IV, respectively. Of the eyes classified as grade III and IV, monocurve and bicurve RGPCL were fitted in 26% and 55%, respectively. In eyes with oval keratoconus, 45%, 35%, and 20% were fitted with monocurve lenses, bicurve lenses, and other lens types, respectively. In eyes with round cones (nipple morphology, 55%, 30%, and 15% were fitted with bicurve lenses, monocurve lenses, and other lens types, respectively. Conclusion: Monocurve RGPCL were most frequently fitted in patients with mild to moderate keratoconus and oval cones morphology, while bicurve lenses were more frequently fitted in patients with severe and advanced keratoconus. This was probably because bicurve lenses are more appropriate for

  12. Contact Stress Design Parameters for Titanium Bearings, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Air-Lock's Phase I effort tested the effects of ball induced contact stresses on Titanium bearing races. The contact stress design limit that would achieve a...

  13. The simulation analysis of contact characteristics of biomimetic ...

    African Journals Online (AJOL)

    Based on the foot structure of the climbing biology and multivariate coupling bionic technology, the bionic flexible convex surface was designed and a 3D model was created using the digital modeling software. Finite Element Analysis software was used for contacting analysis to the bionic flexible convex foot structure in the ...

  14. Finite element analysis of the contact between fuel rod and spacer grid

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Kyu; Kim, Young Koon; Kang, Heung Seok; Yoon, Kyung Ho; Song, Kee Nam [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-01-01

    For the research on the fretting failure problem of nuclear fuel, the contact length and normal stress field are evaluated for the contact between fuel rod and spacer grid by using the Finite Element Method (FEM). An assumption of semi-infiniteness is necessary for applying the Contact Mechanics which is based on the classical theory of elasticity to the present problem. For the contact problem of fuel fretting, the contact mechanical solutions could be utilized well with sufficient accuracy if the contact bodies (i.e., the cladding tube and the spacer grid) can be assumed as semi-infinite bodies. To this end, the contact length evaluated by FEM is discussed together with the relevant research which concerned the effect of dimension for the validity of the assumption of semi-infiniteness. Normal stress profile on the contact is also studied through comparing the theoretical and the FE results. For the analysis of contact problem by FEM, ANSYS code (Version 5.3) is utilized and the geometry is chosen to be the Hertzian (cylinder-to-cylinder), the strip-to-cylinder and the fuel rod/spacer grid contact (strip-to-tube). Present research will be utilized for accessing the fuel fretting problem by FEM together with the theoretical (i.e., contact mechanical) analysis which has been published as KAERI/TR-1113/98. (author). 15 refs., 44 figs., 4 tabs.

  15. On prestress stiffness analysis of bolt-plate contact assemblies

    DEFF Research Database (Denmark)

    Pedersen, Niels Leergaard; Pedersen, Pauli

    2008-01-01

    , but with finite element (FE) and contact analysis, it is possible to find the stiffness of the member. In the case of many connections and for practical applications, it is not suitable to make a full FE analysis. The purpose of the present paper is to find simplified expressions for the stiffness of the member......, including the case when the width of the member is limited. The calculation of the stiffness is based on the FE, including the solution to the contact problem, and we express the stiffness as a function of the elastic energy in the structure, whereby the definition of the displacements related...

  16. The Use of Contact Mode Atomic Force Microscopy in Aqueous Medium for Structural Analysis of Spinach Photosynthetic Complexes

    Energy Technology Data Exchange (ETDEWEB)

    Phuthong, Witchukorn; Huang, Zubin; Wittkopp, Tyler M.; Sznee, Kinga; Heinnickel, Mark L.; Dekker, Jan P.; Frese, Raoul N.; Prinz, Fritz B.; Grossman, Arthur R.

    2015-07-28

    To investigate the dynamics of photosynthetic pigment-protein complexes in vascular plants at high resolution in an aqueous environment, membrane-protruding oxygen-evolving complexes (OECs) associated with photosystem II (PSII) on spinach (Spinacia oleracea) grana membranes were examined using contact mode atomic force microscopy. This study represents, to our knowledge, the first use of atomic force microscopy to distinguish the putative large extrinsic loop of Photosystem II CP47 reaction center protein (CP47) from the putative oxygen-evolving enhancer proteins 1, 2, and 3 (PsbO, PsbP, and PsbQ) and large extrinsic loop of Photosystem II CP43 reaction center protein (CP43) in the PSII-OEC extrinsic domains of grana membranes under conditions resulting in the disordered arrangement of PSII-OEC particles. Moreover, we observed uncharacterized membrane particles that, based on their physical characteristics and electrophoretic analysis of the polypeptides associated with the grana samples, are hypothesized to be a domain of photosystem I that protrudes from the stromal face of single thylakoid bilayers. Our results are interpreted in the context of the results of others that were obtained using cryo-electron microscopy (and single particle analysis), negative staining and freeze-fracture electron microscopy, as well as previous atomic force microscopy studies.

  17. Wetting of biopolymer coatings: contact angle kinetics and image analysis investigation.

    Science.gov (United States)

    Farris, Stefano; Introzzi, Laura; Biagioni, Paolo; Holz, Torsten; Schiraldi, Alberto; Piergiovanni, Luciano

    2011-06-21

    The surface wetting of five biopolymers, used as coating materials for a plastic film, was monitored over a span of 8 min by means of the optical contact angle technique. Because most of the total variation was observed to occur during the first 60 s, we decided to focus on this curtailed temporal window. Initial contact angle values (θ(0)) ranged from ∼91° for chitosan to ∼30° for pullulan. However, the water drop profile began to change immediately following drop deposition for all biocoatings, confirming that the concept of water contact angle equilibrium is not applicable to most biopolymers. First, a three-parameter decay equation [θ(t) = θ(0) exp(kt(n))] was fit to the experimental contact angle data to describe the kinetics of the contact angle change for each biocoating. Interestingly, the k constant correlated well with the contact angle evolution rate and the n exponent seemed to be somehow linked to the physicochemical phenomena underlying the overall kinetics process. Second, to achieve a reliable description of droplet evolution, the contact angle (CA) analysis was coupled with image analysis (IA) through a combined geometric/trigonometric approach. Absorption and spreading were the key factors governing the overall mechanism of surface wetting during the 60 s analysis, although the individual quantification of both phenomena demonstrated that spreading provided the largest contribution for all biopolymers, with the only exception of gelatin, which showed two quasi-equivalent and counterbalancing effects. The possible correlation between these two phenomena and the topography of the biopolymer surfaces are then discussed on the basis of atomic force microscopy analyses. © 2011 American Chemical Society

  18. Contact stress analysis of involute spur gear by Finite Element ...

    African Journals Online (AJOL)

    In this paper the contact stress in rolling-sliding contact of involute spur gear and the effect of coefficient of friction was analyzed. To achieve this, first, three dimensional involute spur gear pairs were developed in Solid works 2012 Premium and the 3D model was exported to ANSYS workbench 14.5. Next, the analysis was ...

  19. Contact Modelling in Isogeometric Analysis: Application to Sheet Metal Forming Processes

    Science.gov (United States)

    Cardoso, Rui P. R.; Adetoro, O. B.; Adan, D.

    2016-08-01

    Isogeometric Analysis (IGA) has been growing in popularity in the past few years essentially due to the extra flexibility it introduces with the use of higher degrees in the basis functions leading to higher convergence rates. IGA also offers the capability of easily reproducing discontinuous displacement and/or strain fields by just manipulating the multiplicity of the knot parametric coordinates. Another advantage of IGA is that it uses the Non-Uniform Rational B-Splines (NURBS) basis functions, that are very common in CAD solid modelling, and consequently it makes easier the transition from CAD models to numerical analysis. In this work it is explored the contact analysis in IGA for both implicit and explicit time integration schemes. Special focus will be given on contact search and contact detection techniques under NURBS patches for both the rigid tools and the deformed sheet blank.

  20. Contact-handled transuranic transportation system structural analysis

    International Nuclear Information System (INIS)

    Lamoreaux, G.H.; Romesberg, L.E.; Sutherland, S.H.; Duffey, T.A.

    1980-01-01

    The Transuranic Package Transporter (TRUPACT) is a Type B overpack being developed for contact-handled transuranic waste. End-on, side-on, and corner impacts of the loaded TRUPACT due to a 9 m drop onto an unyielding surface have been analyzed. In each case the analyses progressed from simplified hand approaches to successively more complex finite element calculations. The first analysis of each series represents the hand calculations which were carried out to obtain initial thicknesses of foam. The remaining analyses were performed using the dynamic and nonlinear analysis capabilities of ADINA, a structural analysis finite element computer program

  1. Labral reconstruction with iliotibial band autografts and semitendinosus allografts improves hip joint contact area and contact pressure: an in vitro analysis.

    Science.gov (United States)

    Lee, Simon; Wuerz, Thomas H; Shewman, Elizabeth; McCormick, Frank M; Salata, Michael J; Philippon, Marc J; Nho, Shane J

    2015-01-01

    Labral reconstruction using iliotibial band (ITB) autografts and semitendinosus (Semi-T) allografts has recently been described in cases of labral deficiency. To characterize the joint biomechanics with a labrum-intact, labrum-deficient, and labrum-reconstructed acetabulum in a hip cadaveric model. The hypothesis was that labral resection would decrease contact area, increase contact pressure, and increase peak force, while subsequent labral reconstruction with ITB autografts or Semi-T allografts would restore these values toward the native intact labral state. Controlled laboratory study. Ten fresh-frozen human cadaveric hips were analyzed utilizing thin-film piezoresistive load sensors to measure contact area, contact pressure, and peak force (1) with the native intact labrum, (2) after segmental labral resection, and (3) after graft labral reconstruction with either ITB autografts or Semi-T allografts. Each specimen was examined at 20° of extension and 60° of flexion. Statistical analysis was conducted through 1-way analysis of variance with post hoc Games-Howell tests. For the ITB group, labral resection significantly decreased contact area (at 20°: 73.2%±5.38%, P=.0010; at 60°: 78.5%±6.93%, P=.0063) and increased contact pressure (at 20°: 106.7%±4.15%, P=.0387; at 60°: 103.9%±1.15%, P=.0428). In addition, ITB reconstruction improved contact area (at 20°: 87.2%±12.3%, P=.0130; at 60°: 90.5%±8.81%, P=.0079) and contact pressure (at 20°: 98.5%±5.71%, P=.0476; at 60°: 96.6%±1.13%, P=.0056) from the resected state. Contact pressure at 60° of flexion was significantly lower compared with the native labrum (P=.0420). For the Semi-T group, labral resection significantly decreased contact area (at 20°: 68.1%±12.57%, P=.0002; at 60°: 67.5%±6.70%, P=.0002) and increased contact pressure (at 20°: 105.3%±3.73%, P=.0304; at 60°: 106.8%±4.04%, P=.0231). Semi-T reconstruction improved contact area (at 20°: 87.9%±7.95%, P=.0087; at 60°: 92.9%±13

  2. Analysis of carbon transport in the EBR-II and FFTF primary sodium systems

    International Nuclear Information System (INIS)

    Snyder, R.B.; Natesan, K.; Kassner, T.F.

    1976-01-01

    An analysis of the carburization-decarburization behavior of austenitic stainless steels in the primary heat-transport systems of the EBR-II and FFTF has been made that is based upon a kinetic model for the diffusion process and the surface area of steel in contact with flowing sodium at various temperatures in the two systems. The analysis was performed for operating conditions that result in sodium outlet temperatures of 474 and 566 0 C in the FFTF and 470 0 C in the EBR-II. If there was no external source of carbon to the system, i.e., other than the carbon initially present in the steel and the sodium, the dynamic-equilibrium carbon concentrations calculated for the FFTF primary sodium were approximately 0.025 and approximately 0.065 ppm for the 474 and 566 0 C outlet temperatures, respectively, and approximately 0.018 ppm for the EBR-II primary system. The analysis indicated that a carbon-source rate of approximately 250 g/y would be required to increase the carbon concentration of the EBR-II sodium to the measured range of approximately 0.16--0.19 ppm. An evaluation of possible carbon sources and the amount of carbonaceous material introduced into the reactor cover gas and sodium suggests that the magnitude of the calculated contamination rate is reasonable. For a 566 0 C outlet temperature, carbonaceous material would have to be introduced into the FFTF primary system at a rate approximately 4--6 times higher than in EBR-II to achieve the same carbon concentration in the sodium in the two systems. Since contamination rates of approximately 1500 g/y are unlikely, high-temperature fuel cladding in the FFTF should exhibit decarburization similar to that observed in laboratory loop systems, in contrast to the minimal compositional changes that result after exposure of Type 316 stainless steel to EBR-II sodium at temperatures between approximately 625 and 650 0 C

  3. Emerging models for facilitating contact between people genetically related through donor conception: a preliminary analysis and discussion

    Directory of Open Access Journals (Sweden)

    Marilyn Crawshaw

    2015-12-01

    Full Text Available Previous research indicates interest among some donor-conceived people, donors and recipient parents in having contact. Outcomes of such contact appear largely, but not universally, positive. This paper seeks to understand better the characteristics of associated support services. Information gathered using the authors' direct experiences and professional and personal networks in different parts of the world indicates the emergence of four main groupings: (i publically funded services outside of treatment centers; (ii services provided by fertility treatment or gamete bank services; (iii services provided privately by independent psychosocial or legal practitioners; and (4 services organized by offspring and/or recipient parents. Key operational features examined were: (i who can access such services and when; (ii what professional standards and funding are in place to provide them; and (iii how ‘matching’ and contact processes are managed. Differences appear influenced variously by the needs of those directly affected, local policies, national legislation and the interests of the fertility services which recruit gamete donors and/or deliver donor conception treatments. The paper is intended to inform fuller debate about how best to meet the needs of those seeking information and contact, the implications for the way that fertility treatment and gametes donation services are currently provided and future research needs.

  4. Characteristic analysis of a traveling wave ultrasonic motor using an ellipsoidal static contact model

    International Nuclear Information System (INIS)

    Lim, Jung Pil; Rho, Jong Seok; Yi, Kyung Pyo; Jung, Hyun Kyo; Seo, Jung Moo

    2009-01-01

    A characteristic analysis of an ultrasonic motor (USM) at the design stage has thus far been impossible. Therefore, a characteristic analysis method is suggested on the basis of a proposed model describing the complex nonlinear contact condition between the rotor and stator. The proposed contact model and analysis method can guide theoretical research on the minimization of the main disadvantages of the USM, which mainly result from the contact mechanism. The validity and usefulness of the suggested analysis method is verified by experimental data from a prototyped USM

  5. Rosacea and contact allergy to cosmetics and topical medicaments--retrospective analysis of multicentre surveillance data 1995-2002.

    Science.gov (United States)

    Jappe, U; Schnuch, A; Uter, W

    2005-02-01

    The role of contact allergy in rosacea has rarely been investigated. In this retrospective study, 361 out of 76,697 patients tested and documented by the Information Network of Departments of Dermatology between 1995 and 2002 had rosacea. Patch tests included standard series and constituents of cosmetics and topical medicaments. 118/361 had additionally been patch tested with their own cosmetics/medicaments. Positive reactions occurred to nickel (II) sulfate in 9.3%, fragrance mix in 8.8%, thimerosal in 6.9%, Myroxylon pereirae resin in 5.9%, potassium dichromate in 4.6% and propolis in 2.8%. Whereas rosacea patients had a significantly higher risk of contact allergy to propolis compared to the remaining patients, in an age- and sex-adjusted analysis, contact allergy to nickel was significantly less frequent in this group. For Lyral, the risk was elevated, albeit not significantly. Only 2/329 patients were positive to neomycin sulfate and 1/100 to gentamicin sulfate, among the panel of (topical) antibiotics tested. Among 118 patients tested with their own products, 3 were tested to metronidazole, 1 reacting positively. Irritant or doubtful patch test reactions were provoked by various substances (vehicles, oxidants and preservatives of various creams), which might also be clinically important, considering the heightened sensitivity of rosaceous skin.

  6. Contact allergy to preservatives in patients with occupational contact dermatitis and exposure analysis of preservatives in registered chemical products for occupational use.

    Science.gov (United States)

    Schwensen, Jakob Ferløv; Friis, Ulrik Fischer; Menné, Torkil; Flyvholm, Mari-Ann; Johansen, Jeanne Duus

    2017-05-01

    The aim of the study is to investigate risk factors for sensitization to preservatives and to examine to which extent different preservatives are registered in chemical products for occupational use in Denmark. A retrospective epidemiological observational analysis of data from a university hospital was conducted. All patients had occupational contact dermatitis and were consecutively patch tested with 11 preservatives from the European baseline series and extended patch test series during a 5-year period: 2009-2013. Information regarding the same preservatives in chemical products for occupational use ('substances and materials') registered in the Danish Product Register Database (PROBAS) was obtained. The frequency of preservative contact allergy was 14.2% (n = 141) in 995 patients with occupational contact dermatitis. Patients with preservative contact allergy had significantly more frequently facial dermatitis (19.9 versus 13.1%) and age > 40 years (71.6 versus 45.8%) than patients without preservative contact allergy, whereas atopic dermatitis was less frequently observed (12.1 versus 19.8%). Preservative contact allergy was more frequent in painters with occupational contact dermatitis as compared to non-painters with occupational contact dermatitis (p contact allergy to methylisothiazolinone and contact allergy to formaldehyde. Analysis of the registered substances and materials in PROBAS revealed that preservatives occurred in several product categories, e.g., 'paints and varnishes', 'cleaning agents', 'cooling agents', and 'polishing agents'. Formaldehyde and isothiazolinones were extensively registered in PROBAS. The extensive use of formaldehyde and isothiazolinones in chemical products for occupational use may be problematic for the worker. Appropriate legislation, substitution, and employee education should be prioritized.

  7. Comparative analysis of Carnaval II Library

    International Nuclear Information System (INIS)

    Santos Bastos, W. dos

    1981-01-01

    The Carnaval II cross sections library from the french fast reactor calculation system is evaluated in two ways: 1 0 ) a comparative analysis of the calculations system for fast reactors at IEN (Instituto de Engenharia Nuclear) using a 'benchmark' model is done; 2 0 ) a comparative analysis in relation to the french system itself is also done, using calculations realized with two versions of the french library: the SETR-II and the CARNAVAL IV, the first one being anterior and the second one posterior to the Carnaval II version, the one used by IEN. (Author) [pt

  8. Analysis and Ranking of Protein-Protein Docking Models Using Inter-Residue Contacts and Inter-Molecular Contact Maps

    KAUST Repository

    Oliva, Romina; Chermak, Edrisse; Cavallo, Luigi

    2015-01-01

    In view of the increasing interest both in inhibitors of protein-protein interactions and in protein drugs themselves, analysis of the three-dimensional structure of protein-protein complexes is assuming greater relevance in drug design. In the many cases where an experimental structure is not available, protein-protein docking becomes the method of choice for predicting the arrangement of the complex. However, reliably scoring protein-protein docking poses is still an unsolved problem. As a consequence, the screening of many docking models is usually required in the analysis step, to possibly single out the correct ones. Here, making use of exemplary cases, we review our recently introduced methods for the analysis of protein complex structures and for the scoring of protein docking poses, based on the use of inter-residue contacts and their visualization in inter-molecular contact maps. We also show that the ensemble of tools we developed can be used in the context of rational drug design targeting protein-protein interactions.

  9. Analysis and Ranking of Protein-Protein Docking Models Using Inter-Residue Contacts and Inter-Molecular Contact Maps

    KAUST Repository

    Oliva, Romina

    2015-07-01

    In view of the increasing interest both in inhibitors of protein-protein interactions and in protein drugs themselves, analysis of the three-dimensional structure of protein-protein complexes is assuming greater relevance in drug design. In the many cases where an experimental structure is not available, protein-protein docking becomes the method of choice for predicting the arrangement of the complex. However, reliably scoring protein-protein docking poses is still an unsolved problem. As a consequence, the screening of many docking models is usually required in the analysis step, to possibly single out the correct ones. Here, making use of exemplary cases, we review our recently introduced methods for the analysis of protein complex structures and for the scoring of protein docking poses, based on the use of inter-residue contacts and their visualization in inter-molecular contact maps. We also show that the ensemble of tools we developed can be used in the context of rational drug design targeting protein-protein interactions.

  10. QCD analysis of neutral and charged current cross sections and search for contact interactions at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Pirumov, Hayk

    2013-11-15

    A QCD analysis of the inclusive deep inelastic ep scattering cross section measured by the H1 experiment at HERA is presented. The data correspond to a total integrated luminosity of about 0.5 fb{sup -1} and covers a kinematic range of 0.5 GeV{sup 2} - 30000 GeV{sup 2} in the negative four-momentum transfer Q{sup 2} and 3 . 10{sup -5} - 0.65 in Bjorken x. The performed QCD analysis of the double differential neutral and charged current cross sections results in a set of parton distribution functions H1PDF 2012. The precise data from HERA II period in the kinematic region of high Q{sup 2} considerably improve the accuracy of the PDFs at the high x. In addition a search for signs of new physics using single differential neutral current cross section measurements at high Q{sup 2} is performed. The observed good agreement of the analysed data with the Standard Model predictions allows to set constraints on various new physics models within the framework of contact interactions. Limits are derived on the compositeness scale for general contact interactions, on the ratio of mass to the Yukawa coupling for heavy leptoquark models, on the effective Plank-mass scale in the large extra dimension models and on the quark radius.

  11. Occupational contact dermatitis in hairdressers/cosmetologists: retrospective analysis of north american contact dermatitis group data, 1994 to 2010.

    Science.gov (United States)

    Warshaw, Erin M; Wang, Michael Z; Mathias, C G Toby; Maibach, Howard I; Belsito, Donald V; Zug, Kathryn A; Taylor, James S; Zirwas, Matthew J; Fransway, Anthony F; Deleo, Vincent A; Marks, James G; Pratt, Melanie D; Storrs, Frances J; Rietschel, Robert L; Fowler, Joseph F; Sasseville, Denis

    2012-01-01

    European studies document that occupational contact dermatitis (CD) is common in hairdressers, but studies from North America are lacking. The objectives of this study were to estimate the prevalence of occupational CD among North American hairdressers/cosmetologists (HD/CS) and to characterize responsible allergens and irritants as well as their sources. A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 1994 and 2010 was conducted. Of 35,842 patients, 432 (1.2%) were HD/CS. Significantly, most of the HD/CS were female (89.8%) and younger than 40 years (55.6%) as compared with non-hairdressers (P Contact Dermatitis Group allergen series missed at least 1 occupationally-related allergen in 26.2% of patients. Contact dermatitis in North American HD/CS is common, and occupationally related allergens are those found in HD/CS products. Supplemental hairdressing/cosmetology antigen series are important in detecting all occupationally related allergens in this population.

  12. Tooth contact analysis of spur gears. Part 1-SAM analysis of standard gears

    Directory of Open Access Journals (Sweden)

    Creţu Spiridon

    2017-01-01

    Full Text Available The involute gears are sensitive to the misalignment of their axes which determines transmission errors and perturbations of pressures distributions along the tooth flank. The concentrated contacts in gears are no longer as Hertz type. A semi-analytical method was developed to find the contact area, pressures distribution and depth stresses state. The matrix of initial separations is found analytically for standard and non-standard spur gears. The presence of misalignment as well as the flank crowning and flank end relief are included in the numerical analysis process.

  13. Association between Contact allergy and Psoriasis

    DEFF Research Database (Denmark)

    Bangsgaard, Nannie

    2011-01-01

    6. SUMMERY 6.1 Summery in English Allergic contact dermatitis (ACD) and psoriasis are the two most prevalent skin diseases in the western world. ACD is the clinical manifestation of contact allergy. Contact allergy and psoriasis are both due to inflammatory mechanisms involving the innate...... and adaptive immune system. Psoriasis is conceived to be an autoimmune disease. Recent studies have suggested an inverse relation between contact allergy and autoimmune diseases. The association between contact allergy and psoriasis could reveal mechanistic insights into both inflammatory processes....... The overall aim of this PhD study was to investigate the association between contact allergy and autoimmune disease, with focus on psoriasis. The work was done in three study parts. Part I Epidemiological studies. Part II Sensitization study and Part III Experimental studies. In part I the association between...

  14. Contact Modelling in Resistance Welding, Part II: Experimental Validation

    DEFF Research Database (Denmark)

    Song, Quanfeng; Zhang, Wenqi; Bay, Niels

    2006-01-01

    Contact algorithms in resistance welding presented in the previous paper are experimentally validated in the present paper. In order to verify the mechanical contact algorithm, two types of experiments, i.e. sandwich upsetting of circular, cylindrical specimens and compression tests of discs...... with a solid ring projection towards a flat ring, are carried out at room temperature. The complete algorithm, involving not only the mechanical model but also the thermal and electrical models, is validated by projection welding experiments. The experimental results are in satisfactory agreement...

  15. Contact Thermal Analysis and Wear Simulation of a Brake Block

    Directory of Open Access Journals (Sweden)

    Nándor Békési

    2013-01-01

    Full Text Available The present paper describes an experimental test and a coupled contact-thermal-wear analysis of a railway wheel/brake block system through the braking process. During the test, the friction, the generated heat, and the wear were evaluated. It was found that the contact between the brake block and the wheel occurs in relatively small and slowly moving hot spots, caused by the wear and the thermal effects. A coupled simulation method was developed including numerical frictional contact, transient thermal and incremental wear calculations. In the 3D simulation, the effects of the friction, the thermal expansion, the wear, and the temperature-dependent material properties were also considered. A good agreement was found between the results of the test and the calculations, both for the thermal and wear results. The proposed method is suitable for modelling the slowly oscillating wear caused by the thermal expansions in the contact area.

  16. Proteomics analysis of dendritic cell activation by contact allergens reveals possible biomarkers regulated by Nrf2

    Energy Technology Data Exchange (ETDEWEB)

    Mussotter, Franz, E-mail: franz.mussotter@bfr.bund.de [German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Berlin (Germany); Tomm, Janina Melanie [Helmholtz Centre for Environmental Research (UFZ), Department of Molecular Systems Biology, Leipzig (Germany); El Ali, Zeina; Pallardy, Marc; Kerdine-Römer, Saadia [INSERM UMR 996, Univ Paris-Sud, Université Paris-Saclay, Chátenay-Malabry (France); Götz, Mario [German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Berlin (Germany); Bergen, Martin von [Helmholtz Centre for Environmental Research (UFZ), Department of Molecular Systems Biology, Leipzig (Germany); University of Leipzig, Institute of Biochemistry, Leipzig (Germany); Aalborg University, Department of Chemistry and Bioscience, Aalborg (Denmark); Haase, Andrea; Luch, Andreas [German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Berlin (Germany)

    2016-12-15

    Allergic contact dermatitis is a widespread disease with high clinical relevance affecting approximately 20% of the general population. Typically, contact allergens are low molecular weight electrophilic compounds which can activate the Keap1/Nrf2 pathway. We performed a proteomics study to reveal possible biomarkers for dendritic cell (DC) activation by contact allergens and to further elucidate the role of Keap1/Nrf2 signaling in this process. We used bone marrow derived dendritic cells (BMDCs) of wild-type (nrf2{sup +/+}) and Nrf2 knockout (nrf2{sup −/−}) mice and studied their response against the model contact sensitizers 2,4-dinitrochlorobenzene (DNCB), cinnamaldehyde (CA) and nickel(II) sulfate by 2-dimensional polyacrylamide gel electrophoresis (2D-PAGE) in combination with electrospray ionization tandem mass spectrometry (ESI-MS/MS). Sodium dodecyl sulfate (SDS, 100 μM) served as irritant control. While treatment with nickel(II) sulfate and SDS had only little effects, CA and DNCB led to significant changes in protein expression. We found 18 and 30 protein spots up-regulated in wild-type cells treated with 50 and 100 μM CA, respectively. For 5 and 10 μM DNCB, 32 and 37 spots were up-regulated, respectively. Almost all of these proteins were not differentially expressed in nrf2{sup −/−} BMDCs, indicating an Nrf2-dependent regulation. Among them proteins were detected which are involved in oxidative stress and heat shock responses, as well as in signal transduction or basic cellular pathways. The applied approach allowed us to differentiate between Nrf2-dependent and Nrf2-independent cellular biomarkers differentially regulated upon allergen-induced DC activation. The data presented might contribute to the further development of suitable in vitro testing methods for chemical-mediated sensitization. - Highlights: • Contact allergens induce proteins involved in DC maturation Nrf2-dependently. • Induction of these proteins points to a functional

  17. Analysis of contact stiffness in ultrasound atomic force microscopy: three-dimensional time-dependent ultrasound modeling

    International Nuclear Information System (INIS)

    Piras, Daniele; Sadeghian, Hamed

    2017-01-01

    Ultrasound atomic force microscopy (US-AFM) has been used for subsurface imaging of nanostructures. The contact stiffness variations have been suggested as the origin of the image contrast. Therefore, to analyze the image contrast, the local changes in the contact stiffness due to the presence of subsurface features should be calculated. So far, only static simulations have been conducted to analyze the local changes in the contact stiffness and, consequently, the contrast in US-AFM. Such a static approach does not fully represent the real US-AFM experiment, where an ultrasound wave is launched either into the sample or at the tip, which modulates the contact stiffness. This is a time-dependent nonlinear dynamic problem rather than a static and stationary one. This paper presents dynamic 3D ultrasound analysis of contact stiffness in US-AFM (in contrast to static analysis) to realistically predict the changes in contact stiffness and thus the changes in the subsurface image contrast. The modulation frequency also influences the contact stiffness variations and, thus, the image contrast. The three-dimensional time-dependent ultrasound analysis will greatly aid in the contrast optimization of subsurface nano imaging with US-AFM. (paper)

  18. Contact With Mental Health Services Prior to Suicide: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Walby, Fredrik A; Myhre, Martin Øverlien; Kildahl, Anine Therese

    2018-04-16

    Access to mental health care is regarded as a central suicide prevention strategy. This is the first systematic review and meta-analysis of the prevalence of contact with mental health services preceding suicide. A systematic search for articles reporting prevalence of contact with mental health services before suicide was conducted in MEDLINE and PsycINFO, restricted to studies published from January 1, 2000, to January 12, 2017. A random-effects meta-analysis with double arcsine transformations was conducted, with meta-regression used to explore heterogeneity. Thirty-five studies were included in the systematic review, and 20 were included in the meta-analysis. Among suicide decedents in the population, 3.7% (95% confidence interval [CI]=2.6%-4.8%) were inpatients at the time of death. In the year before death, 18.3% (CI=14.6%-22.4%) of suicide decedents had contact with inpatient mental health services, 26.1% (CI=16.5%-37.0%) had contact with outpatient mental health services, and 25.7% (CI=22.7%-28.9%) had contact with inpatient or outpatient mental health services. Meta-regression showed that women had significantly higher levels of contact compared with men and that the prevalence of contact with inpatient or outpatient services increased according to the sample year. Contact with services prior to suicide was found to be common and contact with inpatient or outpatient mental health services before suicide seems to be increasing. However, the reviewed studies were mainly conducted in Western European and North American countries, and most studies focused on psychiatric hospitalization, which resulted in limited data on contact with outpatient services. Better monitoring and data on suicides that occur during and after treatment seem warranted.

  19. A Procedure for 3-D Contact Stress Analysis of Spiral Bevel Gears

    Science.gov (United States)

    Kumar, A.; Bibel, G.

    1994-01-01

    Contact stress distribution of spiral bevel gears using nonlinear finite element static analysis is presented. Procedures have been developed to solve the nonlinear equations that identify the gear and pinion surface coordinates based on the kinematics of the cutting process and orientate the pinion and the gear in space to mesh with each other. Contact is simulated by connecting GAP elements along the intersection of a line from each pinion point (parallel to the normal at the contact point) with the gear surface. A three dimensional model with four gear teeth and three pinion teeth is used to determine the contact stresses at two different contact positions in a spiral bevel gearset. A summary of the elliptical contact stress distribution is given. This information will be helpful to helicopter and aircraft transmission designers who need to minimize weight of the transmission and maximize reliability.

  20. Fragrance contact allergy in Iran.

    Science.gov (United States)

    Firooz, A; Nassiri-Kashani, M; Khatami, A; Gorouhi, F; Babakoohi, S; Montaser-Kouhsari, L; Davari, P; Dowlati, Y

    2010-12-01

    Fragrances are considered as one of the most common causes of allergic contact dermatitis. About 1-4% of the general population suffer from fragrance contact allergy (FCA). To determine the frequency of FCA and its clinical relevance in a sample of Iranian patients with history of contact and/or atopic dermatitis from January 2004 to December 2008. Standardized patch testing with 28-allergen screening series recommended by the German Contact Dermatitis Research Group and European Standard Series was used at six dermatological clinics in Iran. Fragrance allergens comprised of fragrance mix I (FM I), Myroxylon pereirae (MP; balsam of Peru), Lyral, turpentine and FM II. Fragrance contact allergy was detected in 7.2% of the patients. The frequency of positive reactions to FM I, MP and FM II were 3.7% (41/1105), 2.8% (32/1135) and 1.1% (3/267) respectively. 82.4% of the reactions to fragrance allergens were clinically relevant. The most common involved areas were hands (68.4%) and face (35.4%). Fragrance allergy predominantly affected women aged more than 40 years (P=0.008). Positive reaction to more than two allergens was significantly higher in FCA patients compared with other contact dermatitis patients (P<0.0001), and FM I, nickel and MP were the most frequent allergens in these patients. Despite less frequency of FCA in comparison with some European countries, its clinical relevance in Iranian patients seems to be high. It mostly affects the hands and the face predominantly in women aged more than 40 years. © 2010 The Authors. Journal compilation © 2010 European Academy of Dermatology and Venereology.

  1. Accident analysis for PRC-II reactor

    International Nuclear Information System (INIS)

    Wei Yongren; Tang Gang; Wu Qing; Lu Yili; Liu Zhifeng

    1997-12-01

    The computer codes, calculation models, transient results, sensitivity research, design improvement, and safety evaluation used in accident analysis for PRC-II Reactor (The Second Pulsed Reactor in China) are introduced. PRC-II Reactor is built in big populous city, so the public pay close attention to reactor safety. Consequently, Some hypothetical accidents are analyzed. They include an uncontrolled control rod withdrawal at rated power, a pulse rod ejection at rated power, and loss of coolant accident. Calculation model which completely depict the principle and process for each accident is established and the relevant analysis code is developed. This work also includes comprehensive computing and analyzing transients for each accident of PRC-II Reactor; the influences in the reactor safety of all kind of sensitive parameters; evaluating the function of engineered safety feature. The measures to alleviate the consequence of accident are suggested and taken in the construction design of PRC-II Reactor. The properties of reactor safety are comprehensively evaluated. A new advanced calculation model (True Core Uncovered Model) of LOCA of PRC-II Reactor and the relevant code (MCRLOCA) are first put forward

  2. A General Contact Force Analysis of an Under-Actuated Finger in Robot Hand Grasping

    Directory of Open Access Journals (Sweden)

    Xuan Vinh Ha

    2016-02-01

    Full Text Available This paper develops a mathematical analysis of contact forces for the under-actuated finger in a general under-actuated robotic hand during grasping. The concept of under-actuation in robotic grasping with fewer actuators than degrees of freedom (DOF, through the use of springs and mechanical limits, allows the hand to adjust itself to an irregularly shaped object without complex control strategies and sensors. Here the main concern is the contact forces, which are important elements in grasping tasks, based on the proposed mathematical analysis of their distributions of the n-DOF under-actuated finger. The simulation results, along with the 3-DOF finger from the ADAMS model, show the effectiveness of the mathematical analysis method, while comparing them with the measured results. The system can find magnitudes of the contact forces at the contact positions between the phalanges and the object.

  3. contact stress analysis of involute spur gear by finite element method

    African Journals Online (AJOL)

    USER

    section using C- programming. Bending stress analysis has been performed using finite element analysis with ANSYS software. Comparison of bending stress analysis has been performed for symmetric and asymmetric spur gear tooth at critical section. Mushin J. Jweeg, et.al. [7] used 2D contact stress FEA model to ...

  4. Numerical analysis of hydrogen-assisted rolling-contact fatigue of wind turbine bearings

    Directory of Open Access Journals (Sweden)

    J. Toribio

    2014-10-01

    Full Text Available Offshore wind parks at locations further from the shore often involve serious difficulties, e.g. the maintenance. The bearings of offshore wind turbines are prone to suffer hydrogen-assisted rolling-contact fatigue (HA-RCF. Three important aspects linked with bearing failures are being extensively researched: (i rolling contact fatigue (RCF, (ii influence of carbide particles on fatigue life, and (iii local microplastic strain accumulation via ratcheting. However, there is no reference related to bearing failure in harsh environment. This way, this paper helps to gain a better understanding of the influence of hydrogen on the service life of offshore wind turbine bearings through a numerical study. So, the widely used RCF ball-on-rod test was simulated by finite element method in order to obtain the stress-strain state inside the bearings during life in service and, from this, to elucidate the potential places where the hydrogen could be more harmful and, therefore, where the bearing material should be improved.

  5. Topology of modified helical gears and Tooth Contact Analysis (TCA) program

    Science.gov (United States)

    Litvin, Faydor L.; Zhang, Jiao

    1989-01-01

    The contents of this report covers: (1) development of optimal geometries for crowned helical gears; (2) a method for their generation; (3) tooth contact analysis (TCA) computer programs for the analysis of meshing and bearing contact of the crowned helical gears; and (4) modelling and simulation of gear shaft deflection. The developed method for synthesis was used to determine the optimal geometry for a crowned helical pinion surface and was directed to localize the bearing contact and guarantee favorable shape and a low level of transmission errors. Two new methods for generation of the crowned helical pinion surface are proposed. One is based on the application of a tool with a surface of revolution that slightly deviates from a regular cone surface. The tool can be used as a grinding wheel or as a shaver. The other is based on a crowning pinion tooth surface with predesigned transmission errors. The pinion tooth surface can be generated by a computer-controlled automatic grinding machine. The TCA program simulates the meshing and bearing contact of the misaligned gears. The transmission errors are also determined. The gear shaft deformation was modelled and investigated. It was found that the deflection of gear shafts has the same effect as gear misalignment.

  6. Ground Contact Analysis for Korea’s Fictitious Lunar Orbiter Mission

    Directory of Open Access Journals (Sweden)

    Young-Joo Song

    2013-12-01

    Full Text Available In this research, the ground contact opportunity for the fictitious low lunar orbiter is analyzed to prepare for a future Korean lunar orbiter mission. The ground contact opportunity is basically derived from geometrical relations between the typical ground stations at the Earth, the relative positions of the Earth and Moon, and finally, the lunar orbiter itself. Both the cut-off angle and the orbiter’s Line of Sight (LOS conditions (weather orbiter is located at near or far side of the Moon seen from the Earth are considered to determine the ground contact opportunities. Four KOMPSAT Ground Stations (KGSs are assumed to be Korea’s future Near Earth Networks (NENs to support lunar missions, and world-wide separated Deep Space Networks (DSNs are also included during the contact availability analysis. As a result, it is concluded that about 138 times of contact will be made between the orbiter and the Daejeon station during 27.3 days of prediction time span. If these contact times are converted into contact duration, the duration is found to be about 8.55 days, about 31.31% of 27.3 days. It is discovered that selected four KGSs cannot provide continuous tracking of the lunar orbiter, meaning that international collaboration is necessary to track Korea’s future lunar orbiter effectively. Possible combinations of world-wide separated DSNs are also suggested to compensate for the lack of contact availability with only four KGSs, as with primary and backup station concepts. The provided algorithm can be easily modified to support any type of orbit around the Moon, and therefore, the presented results could aid further progress in the design field of Korea’s lunar orbiter missions.

  7. Spreading depression analysis of contact behaviour of rats.

    Science.gov (United States)

    Tikal, K

    1977-08-01

    Social contact behaviour induced by spreading cortical depression was studied in rats. The controls looked for and remained in contact, whereas between the rats with spreading cortical depression and their other partners there was no contact. This phenomenon is due mainly to the absence of an active urge for contact. The contact behaviour of rats is evidently controlled by the cerebral cortex or by subcortical areas of the brain which are inhibited after the elicitation of spreading depression. The experiments show that the contact behaviour of rats has at least two components - an active urge for contact and passive tolerance of contact.

  8. Comparative Study on Interface Elements, Thin-Layer Elements, and Contact Analysis Methods in the Analysis of High Concrete-Faced Rockfill Dams

    Directory of Open Access Journals (Sweden)

    Xiao-xiang Qian

    2013-01-01

    Full Text Available This paper presents a study on the numerical performance of three contact simulation methods, namely, the interface element, thin-layer element, and contact analysis methods, through the analysis of the contact behavior between the concrete face slab and the dam body of a high concrete-faced rockfill dam named Tianshengqiao-I in China. To investigate the accuracy and limitations of each method, the simulation results are compared in terms of the dam deformation, contact stress along the interface, stresses in the concrete face slab, and separation of the concrete face slab from the cushion layer. In particular, the predicted dam deformation and slab separation are compared with the in-situ observation data to classify these methods according to their agreement with the in-situ observations. It is revealed that the interface element and thin-layer element methods have their limitations in predicting contact stress, slab separation, and stresses in the concrete face slab if a large slip occurs. The contact analysis method seems to be the best choice whether the separation is finite or not.

  9. Contact-dependent cytopathogenic mechanisms of Trichomonas vaginalis

    Energy Technology Data Exchange (ETDEWEB)

    Krieger, J.N.; Ravdin, J.I.; Rein, M.F.

    1985-12-01

    The cytopathogenic mechanisms of Trichomonas vaginalis have been debated since the 1940s. We examined the following three proposed pathogenic mechanisms: contact-dependent extracellular killing, cytophagocytosis, and extracellular cytotoxins. Serial observations of Chinese hamster ovary (CHO) cell monolayers exposed to trichomonads revealed that (i) trichomonads form clumps, (ii) the clumps adhere to cells in culture, and (iii) monolayer destruction occurs only in areas of contact with T. vaginalis. Kinetic analysis of target cell killing by trichomonads revealed that the probability of CHO cell death was related to the probability of contact with T. vaginalis, supporting the observation by microscopy that trichomonads kill cells only by direct contact. Simultaneous studies of /sup 111/indium oxine label release from CHO cells and trypan blue dye exclusion demonstrated that T. vaginalis kills target cells without phagocytosis. Filtrates of trichomonad cultures or from media in which trichomonads were killing CHO cells had no effect on CHO cell monolayers, indicating that trichomonads do not kill cells by a cell-free or secreted cytotoxin. The microfilament inhibitor cytochalasin D (10 micrograms/ml) inhibited trichomonad killing of CHO cell monolayers by 80% (P less than 0.0001). In contrast, the microtubule inhibitor vinblastine (10(-6) M) caused only 17% inhibition of trichomonad destruction of CHO cell monolayers (P less than 0.020), whereas colchicine (10(-6) M) had no effect. T. vaginalis kills target cells by direct contact without phagocytosis. This event requires intact trichomonad microfilament function; microtubule function appears not to be essential.

  10. Contact-dependent cytopathogenic mechanisms of Trichomonas vaginalis

    International Nuclear Information System (INIS)

    Krieger, J.N.; Ravdin, J.I.; Rein, M.F.

    1985-01-01

    The cytopathogenic mechanisms of Trichomonas vaginalis have been debated since the 1940s. We examined the following three proposed pathogenic mechanisms: contact-dependent extracellular killing, cytophagocytosis, and extracellular cytotoxins. Serial observations of Chinese hamster ovary (CHO) cell monolayers exposed to trichomonads revealed that (i) trichomonads form clumps, (ii) the clumps adhere to cells in culture, and (iii) monolayer destruction occurs only in areas of contact with T. vaginalis. Kinetic analysis of target cell killing by trichomonads revealed that the probability of CHO cell death was related to the probability of contact with T. vaginalis, supporting the observation by microscopy that trichomonads kill cells only by direct contact. Simultaneous studies of 111 indium oxine label release from CHO cells and trypan blue dye exclusion demonstrated that T. vaginalis kills target cells without phagocytosis. Filtrates of trichomonad cultures or from media in which trichomonads were killing CHO cells had no effect on CHO cell monolayers, indicating that trichomonads do not kill cells by a cell-free or secreted cytotoxin. The microfilament inhibitor cytochalasin D (10 micrograms/ml) inhibited trichomonad killing of CHO cell monolayers by 80% (P less than 0.0001). In contrast, the microtubule inhibitor vinblastine (10(-6) M) caused only 17% inhibition of trichomonad destruction of CHO cell monolayers (P less than 0.020), whereas colchicine (10(-6) M) had no effect. T. vaginalis kills target cells by direct contact without phagocytosis. This event requires intact trichomonad microfilament function; microtubule function appears not to be essential

  11. Electro-thermal analysis of contact resistance

    Science.gov (United States)

    Pandey, Nitin; Jain, Ishant; Reddy, Sudhakar; Gulhane, Nitin P.

    2018-05-01

    Electro-Mechanical characterization over copper samples are performed at the macroscopic level to understand the dependence of electrical contact resistance and temperature on surface roughness and contact pressure. For two different surface roughness levels of samples, six levels of load are selected and varied to capture the bulk temperature rise and electrical contact resistance. Accordingly, the copper samples are modelled and analysed using COMSOLTM as a simulation package and the results are validated by the experiments. The interface temperature during simulation is obtained using Mikic-Elastic correlation and by directly entering experimental contact resistance value. The load values are varied and then reversed in a similar fashion to capture the hysteresis losses. The governing equations & assumptions underlying these models and their significance are examined & possible justification for the observed variations are discussed. Equivalent Greenwood model is also predicted by mapping the results of the experiment.

  12. Analysis of the PISC II trials results

    International Nuclear Information System (INIS)

    Haines, N.

    1988-01-01

    The paper presents the analysis scheme of the Programme for the Inspection of Steel Components PISC II trial results. The objective of the PISC II exercise is to evaluate the effectiveness of current and advanced NDT techniques for inspection of reactor pressure vessel components. The analysis scheme takes data from the Round Robin Trial (RRT) and Destructive Examination, then reduces it to a manageable form in order to present useful conclusions on the effectiveness of NDT. A description is given of the data provided by RRT, the data analysis scheme, the definition of analysis parameters, and the main methods of data presentation. (U.K.)

  13. [Current status of the standardization of air impulse tonometers and their evaluation--as an example: the Non-Contact Tonometer II].

    Science.gov (United States)

    Jessen, K; Hoffmann, F

    1983-10-01

    The standard values and tolerances used in the assessment of the clinical efficiency of different types of tonometers are once again demonstrated. Investigations carried out in accordance with the existing test plan for comparative clinical measurements using two non-contact tonometers II (NCT II) and a calibrated applanation tonometer as a reference instrument in 155 patient eyes showed that both the regression equation and the scattering of the individual values around the regression curve satisfy the conditions of clinical assessment criteria. Of the individual values, 2.6% are outside the 95% limits. Following a brief illustration of the measuring principle of the NCT II, a test procedure is described for this type of tonometer. It consists of a torsion balance mounted on a cross-sliding carriage with a small mirror 2.5 mm in diameter and a control balance. A lens equipped with a centering cross is used for adjustment to the nominal distances of 11 mm between the nozzle and the cornea. This test procedure makes it possible to determine whether the digital display of any particular NTC II deviates from the nominal value by not more than +/- 1 digit in the range between "12" and "30" and by not more than +/- 2 digits between "31" and "50".

  14. Influence of Stress Shape Function on Analysis of Contact Problem Using Hybrid Photoelasticity

    International Nuclear Information System (INIS)

    Shin, Dongchul; Hawong, Jaisug

    2013-01-01

    In this research, a study on stress shape functions was conducted to analyze the contact stress problem by using a hybrid photoelasticity. Because the contact stress problem is generally solved as a half-plane problem, the relationship between two analytical stress functions, which are compositions of the Airy stress function, was similar to one of the crack problem. However, this relationship in itself could not be used to solve the contact stress problem (especially one with singular points). Therefore, to analyze the contact stress problem more correctly, stress shape functions based on the condition of two contact end points had to be considered in the form of these two analytical stress functions. The four types of stress shape functions were related to the stress singularities at the two contact end points. Among them, the primary two types used for the analysis of an O-ring were selected, and their validities were verified in this work

  15. Spur gears: Optimal geometry, methods for generation and Tooth Contact Analysis (TCA) program

    Science.gov (United States)

    Litvin, Faydor L.; Zhang, Jiao

    1988-01-01

    The contents of this report include the following: (1) development of optimal geometry for crowned spur gears; (2) methods for their generation; and (3) tooth contact analysis (TCA) computer programs for the analysis of meshing and bearing contact on the crowned spur gears. The method developed for synthesis is used for the determination of the optimal geometry for crowned pinion surface and is directed to reduce the sensitivity of the gears to misalignment, localize the bearing contact, and guarantee the favorable shape and low level of the transmission errors. A new method for the generation of the crowned pinion surface has been proposed. This method is based on application of the tool with a surface of revolution that slightly deviates from a regular cone surface. The tool can be used as a grinding wheel or as a shaver. The crowned pinion surface can also be generated by a generating plane whose motion is provided by an automatic grinding machine controlled by a computer. The TCA program simulates the meshing and bearing contact of the misaligned gears. The transmission errors are also determined.

  16. Non-conformal contact mechanical characteristic analysis on spherical components

    Energy Technology Data Exchange (ETDEWEB)

    Zhen-zhi, G.; Bin, H.; Zheng-ming, G.; Feng-mei, Y.; Jin, Q [The 2. Artillery Engineering Univ., Xi' an (China)

    2017-03-15

    Non-conformal spherical-contact mechanical problems is a three-dimensional coordination or similar to the coordination spherical contact. Due to the complexity of the problem of spherical-contact and difficulties of solving higher-order partial differential equations, problems of three-dimensional coordination or similar to the coordination spherical-contact is still no exact analytical method for solving. It is based on three-dimensional taper model is proposed a model based on the contour surface of the spherical contact and concluded of the formula of the contact pressure and constructed of finite element model by contact pressure distribution under the non-conformal spherical. The results shows spherical contact model can reflect non-conformal spherical-contacting mechanical problems more than taper-contacting model, and apply for the actual project.

  17. Contextualizing Intergroup Contact: Do Political Party Cues Enhance Contact Effects?

    DEFF Research Database (Denmark)

    Sønderskov, Kim Mannemar; Thomsen, Jens Peter Frølund

    2015-01-01

    This article examines intergroup contact effects in different political contexts. We expand on previous efforts of social psychologists by incorporating the messages of political parties as a contextual trigger of group membership awareness in contact situations. We argue that the focus among...... political parties on us-them categorizations heightens the awareness of group memberships. This focus in turn enhances the positive intergroup contact effect by stimulating majority members to perceive contacted persons as prototypical outgroup members. A multilevel analysis of 22 countries and almost 37......,000 individuals confirms that the ability of intergroup contact to reduce antiforeigner sentiment increases when political parties focus intensively on immigration issues and cultural differences. Specifically, both workplace contact and interethnic friendship become more effective in reducing antiforeigner...

  18. The Transfer efficiency analysis and modeling technology of new non - contact power transmission equipment

    Directory of Open Access Journals (Sweden)

    Cao Shi

    2017-01-01

    Full Text Available Due to the shortcomings of current power transmission which is used in ultrasound - assisted machining and the different transfer efficiency caused by the related parameters of the electromagnetic converter, this paper proposes an analysis model of the new non-contact power transmission device with more stable output and higher transmission efficiency. Then By utilizing Maxwell finite element analysis software, this paper studies the law of the transfer efficiency of the new non-contact transformer and compares new type with traditional type with the method of setting the boundary conditions of non-contact power supply device. At last, combining with the practical application, the relevant requirements which have a certain reference value in the application are put forward in the actual processing.

  19. Association between atopic dermatitis and contact sensitization: A systematic review and meta-analysis.

    Science.gov (United States)

    Hamann, Carsten R; Hamann, Dathan; Egeberg, Alexander; Johansen, Jeanne D; Silverberg, Jonathan; Thyssen, Jacob P

    2017-07-01

    It is unclear whether patients with atopic dermatitis (AD) have an altered prevalence or risk for contact sensitization. Increased exposure to chemicals in topical products together with impaired skin barrier function suggest a higher risk, whereas the immune profile suggests a lower risk. To perform a systematic review and meta-analysis of the association between AD and contact sensitization. The PubMed/Medline, Embase, and Cochrane databases were searched for articles that reported on contact sensitization in individuals with and without AD. The literature search yielded 10,083 citations; 417 were selected based on title and abstract screening and 74 met inclusion criteria. In a pooled analysis, no significant difference in contact sensitization between AD and controls was evident (random effects model odds ratio [OR] = 0.891; 95% confidence interval [CI] = 0.771-1.03). There was a positive correlation in studies that compared AD patients with individuals from the general population (OR 1.50, 95% CI 1.23-1.93) but an inverse association when comparing with referred populations (OR 0.753, 95% CI 0.63-0.90). Included studies used different tools to diagnose AD and did not always provide information on current or past disease. Patch test allergens varied between studies. No overall relationship between AD and contact sensitization was found. We recommend that clinicians consider patch testing AD patients when allergic contact dermatitis is suspected. Copyright © 2017 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  20. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    Science.gov (United States)

    O'Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-08-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact. This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface.

  1. Design, fabrication and skin-electrode contact analysis of polymer microneedle-based ECG electrodes

    International Nuclear Information System (INIS)

    O’Mahony, Conor; Grygoryev, Konstantin; Ciarlone, Antonio; Giannoni, Giuseppe; Kenthao, Anan; Galvin, Paul

    2016-01-01

    Microneedle-based ‘dry’ electrodes have immense potential for use in diagnostic procedures such as electrocardiography (ECG) analysis, as they eliminate several of the drawbacks associated with the conventional ‘wet’ electrodes currently used for physiological signal recording. To be commercially successful in such a competitive market, it is essential that dry electrodes are manufacturable in high volumes and at low cost. In addition, the topographical nature of these emerging devices means that electrode performance is likely to be highly dependent on the quality of the skin-electrode contact.This paper presents a low-cost, wafer-level micromoulding technology for the fabrication of polymeric ECG electrodes that use microneedle structures to make a direct electrical contact to the body. The double-sided moulding process can be used to eliminate post-process via creation and wafer dicing steps. In addition, measurement techniques have been developed to characterize the skin-electrode contact force. We perform the first analysis of signal-to-noise ratio dependency on contact force, and show that although microneedle-based electrodes can outperform conventional gel electrodes, the quality of ECG recordings is significantly dependent on temporal and mechanical aspects of the skin-electrode interface. (paper)

  2. The Mathematical and Computer Aided Analysis of the Contact Stress of the Surface With 4th Order

    Science.gov (United States)

    Huran, Liu

    Inspired from some gears with heavy power transmission in practical usage after serious plastic deformation in metallurgical industry, we believe that there must existed some kind of gear profile which is most suitable in both the contact and bending fatigue strength. From careful analysis and deep going investigation, we think that it is the profile of equal conjugate curvature with high order of contact, and analyzed the forming principle of this kind of profile. Based on the second curve and comparative analysis of fourth order curves, combined with Chebyshev polynomial terms of higher order contact with tooth contact stress formula derived. Note high exposure in the case of two extreme points of stress and extreme positions and the derived extreme contact stress formula. Finally, a pair of conjugate gear tooth profile curvature provides specific contact stress calculation.

  3. Three-dimensional finite analysis of acetabular contact pressure and contact area during normal walking.

    Science.gov (United States)

    Wang, Guangye; Huang, Wenjun; Song, Qi; Liang, Jinfeng

    2017-11-01

    This study aims to analyze the contact areas and pressure distributions between the femoral head and mortar during normal walking using a three-dimensional finite element model (3D-FEM). Computed tomography (CT) scanning technology and a computer image processing system were used to establish the 3D-FEM. The acetabular mortar model was used to simulate the pressures during 32 consecutive normal walking phases and the contact areas at different phases were calculated. The distribution of the pressure peak values during the 32 consecutive normal walking phases was bimodal, which reached the peak (4.2 Mpa) at the initial phase where the contact area was significantly higher than that at the stepping phase. The sites that always kept contact were concentrated on the acetabular top and leaned inwards, while the anterior and posterior acetabular horns had no pressure concentration. The pressure distributions of acetabular cartilage at different phases were significantly different, the zone of increased pressure at the support phase distributed at the acetabular top area, while that at the stepping phase distributed in the inside of acetabular cartilage. The zones of increased contact pressure and the distributions of acetabular contact areas had important significance towards clinical researches, and could indicate the inductive factors of acetabular osteoarthritis. Copyright © 2016. Published by Elsevier Taiwan.

  4. The effect of bottom boundary condition type on the behavior of adhesive contact of spherical probe on an elastic film

    International Nuclear Information System (INIS)

    Zhu, X; Xu, W

    2017-01-01

    This study presents an investigation on the behavior of adhesive contact between a rigid sphere and an elastic film which is either perfectly bonded (case I) or in frictionless contact (case II) with a rigid substrate. By using linear fracture mechanics, we formulate an convenient semi-analytical approach to develop relations between the applied force, penetration depth and contact radius. Finite element analysis (FEA) is used to verify the relationships. Our results reveal that the interfacial boundary conditions between the film and substrate have distinct effects on the adhesive contact behavior between the sphere and the film. The aim of the present study is to provide an instructive inspiration for controlling adhesion strength of the thin film subject to adhesive contact. (paper)

  5. Removal of Cu(II) and Pb(II) from Aqueous Solutions Using Nanoporous Materials

    Science.gov (United States)

    Dutta, Debajani; Roy, Sushanta Kumar; Das, Bodhaditya; Talukdar, Anup K.

    2018-05-01

    The present work deals with the adsorption of Cu2+ and Pb2+ on zeolites (ZSM-5, mordenite) and mesoporous materials (MCM-48, MCM-41). The characterization of the synthesized samples was performed by means of XRD, SEM, and thermogravimetric analysis. The batch method was employed to study the influence of adsorbent nature, contact time, initial metal ion concentration, and adsorbent load. The adsorption on MCM-48 follows a pseudo-second-order kinetic model. This material was found to be more effective for the removal of lead in a batch process as compared to the other adsorbents and the removal efficiency of the materials for Pb(II) followed the order MCM-48 > mordenite > ZSM-5 > MCM-41 and that for Cu(II) followed the order ZSM-5 > mordenite > MCM-41 > MCM-48.

  6. American Contact Dermatitis Society Contact Allergy Management Program: An Epidemiologic Tool to Determine Relative Prevalence of Contact Allergens.

    Science.gov (United States)

    Scheman, Andrew; Severson, David

    2016-01-01

    Data on the prevalence of contact allergy in North America are currently reported by groups of academic contact allergy specialists at select academic centers. Sampling of data from numerous centers across North America, including practices performing more limited patch testing, would provide a broader perspective of contact allergen prevalence in North America. The American Contact Dermatitis Society Contact Allergy Management Program is an ideal tool for collection of epidemiologic data regarding contact allergy prevalence in North America. The aim of the study was to identify the relative prevalence of contact allergy to common contact allergens in North America. Mapping of Contact Allergy Management Program (CAMP) data was performed to allow analysis of how frequently searches were performed for various contact allergens. The number of searches performed for specific allergens provides a measure of the relative prevalence of contact allergy to these allergens. The top 35 allergens for the period from November 18, 2012 to November 18, 2013 are reported. Although these data are useful, specific recommendations for minor alterations to CAMP are discussed, which will allow future CAMP data to be stratified and more powerful. With minor modifications, CAMP can provide a quantum leap in the reporting of contact allergy epidemiologic data in North America.

  7. Tightly coupled transient analysis of EBR-II

    International Nuclear Information System (INIS)

    Makowitz, H.; Lehto, W.K.; Sackett, J.I.

    1988-01-01

    A Tightly Coupled transient analysis system for the Experimental Breeder Reactor-II (EBR-II) is currently being tested. The system consists of a faster than real time high fidelity reactor simulation, advanced graphics displays, expert system coupling, and real time data coupling via the EBR-II data acquisition system to and from the plant and the control system. The base, first generation software has been developed and is presently being tested. Various subsystem couplings and the total system integration are being checked out. This system should enhance the diagnostic and prognostic capability of EBR-II in the near term and provide automatic control during startup and power maneuvering in the future, as well as serve as a testbed for new control system development for advanced reactors

  8. Stress analysis of disconnected structures in contact through finite element gaps

    International Nuclear Information System (INIS)

    Stadter, J.T.; Weiss, R.O.

    1976-07-01

    A numerical procedure is presented for analyzing thermal stress problems of disconnected structures in contact across separations or gaps. The new procedure is called SAASGAPS, an adaptation of the basic SAAS III computer program. The SAAS program uses the finite element method and allows analyses of plane and axisymmetric bodies with temperature dependent material properties, subject to thermal and mechanical loads. A secant modulus approach with a bilinear stress-strain curve is used for elastic-plastic problems. The SAASGAPS version contains all of the features of the original SAAS program. A special gap element is used together with a stress invariance principle to model the contact process. The iterative procedure implemented in SAASGAPS is described. Results are discussed for five problems involving frictionless contact. Two of these problems are associated with the thermal stress analysis of the heat shield for the Multi-Hundred Watt Radioisotope Thermoelectric Generator. Input instructions for the program are described in an appendix

  9. Clinical patch test data evaluated by multivariate analysis. Danish Contact Dermatitis Group

    DEFF Research Database (Denmark)

    Christophersen, J; Menné, T; Tanghøj, P

    1989-01-01

    The aim of the present study was to evaluate the influence of individual explanatory factors, such as sex, age, atopy, test time and presence of diseased skin, on clinical patch test results, by application of multivariate statistical analysis. The study population was 2166 consecutive patients...... patch tested with the standard series of the International Contact Dermatitis Research Group (ICDRG) by members of the Danish Contact Dermatitis Group (DCDG) over a period of 6 months. For the 8 test allergens most often found positive (nickel, fragrance-mix, cobalt, chromate, balsam of Peru, carba......-mix, colophony, and formaldehyde), one or more individual factors were of significance for the risk of being sensitized, except for chromate and formaldehyde. It is concluded that patch test results can be compared only after stratification of the material or by multivariate analysis....

  10. Contact Stress Analysis for Gears of Different Helix Angle Using Finite Element Method

    Directory of Open Access Journals (Sweden)

    Patil Santosh

    2014-07-01

    Full Text Available The gear contact stress problem has been a great point of interest for many years, but still an extensive research is required to understand the various parameters affecting this stress. Among such parameters, helix angle is one which has played a crucial role in variation of contact stress. Numerous studies have been carried out on spur gear for contact stress variation. Hence, the present work is an attempt to study the contact stresses among the helical gear pairs, under static conditions, by using a 3D finite element method. The helical gear pairs on which the analysis is carried are 0, 5, 15, 25 degree helical gear sets. The Lagrange multiplier algorithm has been used between the contacting pairs to determine the stresses. The helical gear contact stress is evaluated using FE model and results have also been found at different coefficient of friction, varying from 0.0 to 0.3. The FE results have been further compared with the analytical calculations. The analytical calculations are based upon Hertz and AGMA equations, which are modified to include helix angle. The commercial finite element software was used in the study and it was shown that this approach can be applied to gear design efficiently. The contact stress results have shown a decreasing trend, with increase in helix angle.

  11. Wet Wipe Allergens: Retrospective Analysis From the North American Contact Dermatitis Group 2011-2014.

    Science.gov (United States)

    Warshaw, Erin M; Aschenbeck, Kelly A; Zug, Kathryn A; Belsito, Donald V; Zirwas, Matthew J; Fowler, Joseph F; Taylor, James S; Sasseville, Denis; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Maibach, Howard I; Mathias, C G Toby; DeKoven, Joel G

    Although there are several case reports of wet wipe-associated contact dermatitis, the prevalence of wipes as a source of allergic contact dermatitis in larger populations and the responsible allergens are largely unknown. The aim of the study was to determine the prevalence of wet wipes as a source of contact allergy and the most commonly associated allergens in a North American tertiary referral patch test population. Data collected from 2011 to 2014 by the North American Contact Dermatitis Group was used to conduct a retrospective cross-sectional analysis of patient demographics and patch test results associated with the triple-digit source code for "wet wipe." Of the 9037 patients patch tested during the study period, 79 (0.9%) had a positive patch test reaction to an allergen identified with a wet wipe source. The most commonly associated allergens were preservatives, including the following: methylisothiazolinone (MI) (59.0%), methylchloroisothiazolinone (MCI)/MI (35.6%), bronopol (2-bromo-2-nitropropane-1,3-diol) (27.4%), and iodopropynyl butylcarbamate (12.3%). Fragrance (combined) represented 12.3%. Anal/genital dermatitis was 15 times more likely (P contact allergy had their contact allergens detected by the North American Contact Dermatitis Group screening series. Wet wipes are an important source of contact allergy. Preservatives are the main allergens, especially isothiazolinones.

  12. Numerical and experimental analysis of thermosonic bond strength considering interfacial contact phenomena

    International Nuclear Information System (INIS)

    He Jun; Guo Yongjin; Lin Zhongqin

    2008-01-01

    The theoretical equation of thermosonic bond strength involving interfacial deformation and microcontact phenomena is presented in this study. The constitutive equation of gold considering the ultrasonic softening mechanism was developed based on the thermosonic bonding experiments and coded into the FE software. The numerical model of bonding was established to estimate the surface exposure and the effective normal pressure. The real contact area was calculated by a microcontact model. Accordingly, the nominal bond strength can be obtained and verified by the experimental data. It is found that a better conjunction exists at the edge of the contact area because large surface exposure is produced there, which is also proved by the SEM image of a sheared ball bond. Increasing the bonding force or the ultrasonic power will increase the interfacial plastic deformation, the nominal and real contact areas, but decreases the effective normal pressure. The contact ratio increases to a maximum with the increase in the bonding force, and then decreases while it continues to decrease with the increase in the ultrasonic power. In addition, both the stress analysis and experimental result show that cratering and damage to the pad structure are easily produced below the edge region of the contact area under an excessive bonding force or ultrasonic power

  13. The first photometric analysis of the near contact binary IR Cas

    International Nuclear Information System (INIS)

    Li, Kai; Hu, S.-M.; Guo, D.-F.; Jiang, Y.-G.; Gao, D.-Y.; Chen, X.

    2014-01-01

    The first photometric analysis of IR Cas was carried out based on the new observed BVRI light curves. The symmetric light curves and nearly flat secondary minimum indicate that very precise photometric results can be determined. We found that IR Cas is a near contact binary with the primary component filling its Roche lobe. An analysis of the O – C diagram based on all available times of minimum light reveals evidence for a periodic change with a semi-amplitude of 0.0153 days and a period of 39.7 yr superimposed on a secular decrease at a rate of dp/dt = –1.28(± 0.09) × 10 –7 days yr –1 . The most reasonable explanation for the periodic change is the light time-travel effect due to a third body. The period decrease may be caused by mass transfer from the primary component to the secondary. With the decreasing period, IR Cas would eventually evolve into a contact system.

  14. Patch test results with fragrance markers of the baseline series - analysis of the European Surveillance System on Contact Allergies (ESSCA) network 2009-2012.

    Science.gov (United States)

    Frosch, Peter J; Duus Johansen, Jeanne; Schuttelaar, Marie-Louise A; Silvestre, Juan F; Sánchez-Pérez, Javier; Weisshaar, Elke; Uter, Wolfgang

    2015-09-01

    Contact allergy to fragrances is common, and impairs quality of life, particularly in young women. To provide current results on the prevalences of sensitization to fragrance allergens used as markers in the baseline series of most European countries. Data of patients consecutively patch tested between 2009 and 2012 in 12 European countries with fragrance allergens contained in the baseline series were collected by the European Surveillance System on Contact Allergies network and descriptively analysed. Four departments used the TRUE Test(®) system. The 'basic markers' were tested on 51 477 [fragrance mix II (FM II)] to 57 123 [Myroxylon pereirae, balsam of Peru] patients, and yielded positive reactions as follows: fragrance mix I 6.9%, Myroxylon pereirae 5.4%, FM II 3.8%, colophonium 2.6%, and hydroxyisohexyl 3-cyclohexene carboxaldehyde 1.7%, with some regional differences. Prevalences with TRUE Test(®) allergens were lower. Additional fragrances were tested on 3643 (trimethylbenzenepropanol) to 14 071 (oil of turpentine) patients, and yielded between 2.6% (Cananga odorata) and 0.7% (trimethylbenzenepropanol) positive reactions. Contact allergy to fragrances is common throughout Europe, with regional variation probably being explained by patch test technique, and differences in exposure and referral patterns. The current basic markers of fragrance sensitivity in the baseline series should be supplemented with additional fragrance allergens. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Reliable Solution of a Unilateral Contact Problem with Friction and Uncertain Data in Thermo-Elasticity

    Czech Academy of Sciences Publication Activity Database

    Hlaváček, Ivan; Nedoma, Jiří

    2005-01-01

    Roč. 67, - (2005), s. 559-580 ISSN 0378-4754 R&D Projects: GA ČR GA201/01/1200; GA MŠk OK 407 Grant - others:COPERNICUS-HIPERGEOS II(XE) KIT 977006 Institutional research plan: CEZ:AV0Z1030915 Keywords : unilateral contact * steady-state heat flow * Coulomb friction * finite element analysis * radioactive waste repositories Subject RIV: BA - General Mathematics Impact factor: 0.554, year: 2005

  16. Comparative meta-analysis of tuberculosis contact investigation interventions in eleven high burden countries.

    Directory of Open Access Journals (Sweden)

    Lucie Blok

    Full Text Available Screening of household contacts of tuberculosis (TB patients is a recommended strategy to improve early case detection. While it has been widely implemented in low prevalence countries, the most optimal protocols for contact investigation in high prevalence, low resource settings is yet to be determined. This study evaluated contact investigation interventions in eleven lower and middle income countries and reviewed the association between context or program-related factors and the yield of cases among contacts.We reviewed data from nineteen first wave TB REACH funded projects piloting innovations to improve case detection. These nineteen had fulfilled the eligibility criteria: contact investigation implementation and complete data reporting. We performed a cross-sectional analysis of the percentage yield and case notifications for each project. Implementation strategies were delineated and the association between independent variables and yield was analyzed by fitting a random effects logistic regression.Overall, the nineteen interventions screened 139,052 household contacts, showing great heterogeneity in the percentage yield of microscopy confirmed cases (SS+, ranging from 0.1% to 6.2%. Compared to the most restrictive testing criteria (at least two weeks of cough the aOR's for lesser (any TB related symptom and least (all contacts restrictive testing criteria were 1.71 (95%CI 0.94-3.13 and 6.90 (95% CI 3.42-13.93 respectively. The aOR for inclusion of SS- and extra-pulmonary TB was 0.31 (95% CI 0.15-0.62 compared to restricting index cases to SS+ TB. Contact investigation contributed between <1% and 14% to all SS+ cases diagnosed in the intervention areas.This study confirms that high numbers of active TB cases can be identified through contact investigation in a variety of contexts. However, design and program implementation factors appear to influence the yield of contact investigation and its concomitant contribution to TB case detection.

  17. Measuring contact area in a sliding human finger-pad contact.

    Science.gov (United States)

    Liu, X; Carré, M J; Zhang, Q; Lu, Z; Matcher, S J; Lewis, R

    2018-02-01

    The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Occupational Contact Dermatitis in Mechanics and Repairers Referred for Patch Testing: Retrospective Analysis From the North American Contact Dermatitis Group 1998-2014.

    Science.gov (United States)

    Warshaw, Erin M; Hagen, Solveig L; Sasseville, Denis; Maibach, Howard I; DeKoven, Joel G; Belsito, Donald V; Fowler, Joseph F; Zug, Kathryn A; Taylor, James S; Mathias, C G Toby; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Zirwas, Matthew J; Storrs, Frances J

    Contact dermatoses are common in mechanic and repair occupations. This study aimed to (1) estimate the prevalence of occupationally related contact dermatitis among mechanics/repairers patch tested from 1998 to 2014 by the North American Contact Dermatitis Group, (2) characterize responsible allergens and irritants, and their sources, and (3) compare results among 3 occupational subgroups (mechanics, electrical/electronic, and other). A cross-sectional analysis of patients patch tested by the North American Contact Dermatitis Group between 1998 and 2014. Of 38,784 patients patch tested, 691 (1.8%) were mechanics/repairers. Male sex (93.5%) and hand involvement (59.5%) were common overall. Occupationally related skin disease was more prevalent among vehicle and mobile equipment mechanics/repairers (52.7%) and other mechanics/repairers (41.4%) than electrical/electronic equipment mechanics/repairers (21.3%). Overall, carba mix, thiuram mix, and methylchloroisothiazolone/methylisothiazolone were the most common occupation-related clinically relevant allergens. Gloves, automotive vehicles, solvents, oils, lubricants, and fuels were the most common sources of responsible allergens. Common occupationally related allergens included rubber accelerators and the preservative methylchloroisothiazolone/methylisothiazolone.

  19. Simulation of thermal stresses in anode-supported solid oxide fuel cell stacks. Part II: Loss of gas-tightness, electrical contact and thermal buckling

    Science.gov (United States)

    Nakajo, Arata; Wuillemin, Zacharie; Van herle, Jan; Favrat, Daniel

    Structural stability issues in planar solid oxide fuel cells arise from the mismatch between the coefficients of thermal expansion of the components. The stress state at operating temperature is the superposition of several contributions, which differ depending on the component. First, the cells accumulate residual stresses due to the sintering phase during the manufacturing process. Further, the load applied during assembly of the stack to ensure electric contact and flatten the cells prevents a completely stress-free expansion of each component during the heat-up. Finally, thermal gradients cause additional stresses in operation. The temperature profile generated by a thermo-electrochemical model implemented in an equation-oriented process modelling tool (gPROMS) was imported into finite-element software (ABAQUS) to calculate the distribution of stress and contact pressure on all components of a standard solid oxide fuel cell repeat unit. The different layers of the cell in exception of the cathode, i.e. anode, electrolyte and compensating layer were considered in the analysis to account for the cell curvature. Both steady-state and dynamic simulations were performed, with an emphasis on the cycling of the electrical load. The study includes two different types of cell, operation under both thermal partial oxidation and internal steam-methane reforming and two different initial thicknesses of the air and fuel compressive sealing gaskets. The results generated by the models are presented in two papers: Part I focuses on cell cracking. In the present paper, Part II, the occurrences of loss of gas-tightness in the compressive gaskets and/or electrical contact in the gas diffusion layer were identified. In addition, the dependence on temperature of both coefficients of thermal expansion and Young's modulus of the metallic interconnect (MIC) were implemented in the finite-element model to compute the plastic deformation, while the possibilities of thermal buckling

  20. ComplexContact: a web server for inter-protein contact prediction using deep learning

    KAUST Repository

    Zeng, Hong; Wang, Sheng; Zhou, Tianming; Zhao, Feifeng; Li, Xiufeng; Wu, Qing; Xu, Jinbo

    2018-01-01

    ComplexContact (http://raptorx2.uchicago.edu/ComplexContact/) is a web server for sequence-based interfacial residue-residue contact prediction of a putative protein complex. Interfacial residue-residue contacts are critical for understanding how proteins form complex and interact at residue level. When receiving a pair of protein sequences, ComplexContact first searches for their sequence homologs and builds two paired multiple sequence alignments (MSA), then it applies co-evolution analysis and a CASP-winning deep learning (DL) method to predict interfacial contacts from paired MSAs and visualizes the prediction as an image. The DL method was originally developed for intra-protein contact prediction and performed the best in CASP12. Our large-scale experimental test further shows that ComplexContact greatly outperforms pure co-evolution methods for inter-protein contact prediction, regardless of the species.

  1. ComplexContact: a web server for inter-protein contact prediction using deep learning

    KAUST Repository

    Zeng, Hong

    2018-05-20

    ComplexContact (http://raptorx2.uchicago.edu/ComplexContact/) is a web server for sequence-based interfacial residue-residue contact prediction of a putative protein complex. Interfacial residue-residue contacts are critical for understanding how proteins form complex and interact at residue level. When receiving a pair of protein sequences, ComplexContact first searches for their sequence homologs and builds two paired multiple sequence alignments (MSA), then it applies co-evolution analysis and a CASP-winning deep learning (DL) method to predict interfacial contacts from paired MSAs and visualizes the prediction as an image. The DL method was originally developed for intra-protein contact prediction and performed the best in CASP12. Our large-scale experimental test further shows that ComplexContact greatly outperforms pure co-evolution methods for inter-protein contact prediction, regardless of the species.

  2. ComplexContact: a web server for inter-protein contact prediction using deep learning.

    Science.gov (United States)

    Zeng, Hong; Wang, Sheng; Zhou, Tianming; Zhao, Feifeng; Li, Xiufeng; Wu, Qing; Xu, Jinbo

    2018-05-22

    ComplexContact (http://raptorx2.uchicago.edu/ComplexContact/) is a web server for sequence-based interfacial residue-residue contact prediction of a putative protein complex. Interfacial residue-residue contacts are critical for understanding how proteins form complex and interact at residue level. When receiving a pair of protein sequences, ComplexContact first searches for their sequence homologs and builds two paired multiple sequence alignments (MSA), then it applies co-evolution analysis and a CASP-winning deep learning (DL) method to predict interfacial contacts from paired MSAs and visualizes the prediction as an image. The DL method was originally developed for intra-protein contact prediction and performed the best in CASP12. Our large-scale experimental test further shows that ComplexContact greatly outperforms pure co-evolution methods for inter-protein contact prediction, regardless of the species.

  3. An algorithm for selecting the most accurate protocol for contact angle measurement by drop shape analysis.

    Science.gov (United States)

    Xu, Z N

    2014-12-01

    In this study, an error analysis is performed to study real water drop images and the corresponding numerically generated water drop profiles for three widely used static contact angle algorithms: the circle- and ellipse-fitting algorithms and the axisymmetric drop shape analysis-profile (ADSA-P) algorithm. The results demonstrate the accuracy of the numerically generated drop profiles based on the Laplace equation. A significant number of water drop profiles with different volumes, contact angles, and noise levels are generated, and the influences of the three factors on the accuracies of the three algorithms are systematically investigated. The results reveal that the above-mentioned three algorithms are complementary. In fact, the circle- and ellipse-fitting algorithms show low errors and are highly resistant to noise for water drops with small/medium volumes and contact angles, while for water drop with large volumes and contact angles just the ADSA-P algorithm can meet accuracy requirement. However, this algorithm introduces significant errors in the case of small volumes and contact angles because of its high sensitivity to noise. The critical water drop volumes of the circle- and ellipse-fitting algorithms corresponding to a certain contact angle error are obtained through a significant amount of computation. To improve the precision of the static contact angle measurement, a more accurate algorithm based on a combination of the three algorithms is proposed. Following a systematic investigation, the algorithm selection rule is described in detail, while maintaining the advantages of the three algorithms and overcoming their deficiencies. In general, static contact angles over the entire hydrophobicity range can be accurately evaluated using the proposed algorithm. The ease of erroneous judgment in static contact angle measurements is avoided. The proposed algorithm is validated by a static contact angle evaluation of real and numerically generated water drop

  4. Structural and Contact Analysis of a 3-Dimensional Disc-Pad Model with and without Thermal Effects

    Directory of Open Access Journals (Sweden)

    A. Belhocine

    2014-12-01

    Full Text Available The motivation of this work is to identify thermal effects on the structural and contact behaviour of a disc-pad assembly using a finite element approach. The first analysis is performed on the disc-pad model without the presence of thermal properties. Structural performance of the disc-pad model such as deformation and Von Mises stress is predicted. Next, thermomechanical analysis is performed on the same disc-pad model with the inclusion of convection, adiabatic and heat flux elements. The prediction results of temperature distribution, deformation, stress and contact pressure are presented. Comparison of the structural performance between the two analyses (mechanical and thermomechanical is also made. From this study, it can assist brake engineers to choose a suitable analysis in order to critically evaluate structural and contact behaviour of the disc brake assembly.

  5. Numerical analysis II essentials

    CERN Document Server

    REA, The Editors of; Staff of Research Education Association

    1989-01-01

    REA's Essentials provide quick and easy access to critical information in a variety of different fields, ranging from the most basic to the most advanced. As its name implies, these concise, comprehensive study guides summarize the essentials of the field covered. Essentials are helpful when preparing for exams, doing homework and will remain a lasting reference source for students, teachers, and professionals. Numerical Analysis II covers simultaneous linear systems and matrix methods, differential equations, Fourier transformations, partial differential equations, and Monte Carlo methods.

  6. Computational contact and impact mechanics fundamentals of modeling interfacial phenomena in nonlinear finite element analysis

    CERN Document Server

    Laursen, Tod A

    2003-01-01

    This book comprehensively treats the formulation and finite element approximation of contact and impact problems in nonlinear mechanics. Intended for students, researchers and practitioners interested in numerical solid and structural analysis, as well as for engineers and scientists dealing with technologies in which tribological response must be characterized, the book includes an introductory but detailed overview of nonlinear finite element formulations before dealing with contact and impact specifically. Topics encompassed include the continuum mechanics, mathematical structure, variational framework, and finite element implementations associated with contact/impact interaction. Additionally, important and currently emerging research topics in computational contact mechanics are introduced, encompassing such topics as tribological complexity, conservative treatment of inelastic impact interaction, and novel spatial discretization strategies.

  7. Occupational contact dermatitis in painters - an analysis of patch test data from the Danish Contact Dermatitis Group

    DEFF Research Database (Denmark)

    Mose, Anja P; Lundov, Michael Dyrgaard; Zachariae, Claus

    2012-01-01

    Background. Painters are among the occupational groups that most commonly experience occupational contact dermatitis, but few investigations exist concerning this occupation. Objectives. To characterize painters with contact dermatitis and identify the most common allergens associated...... with the occupation. Materials and methods. All patch test results of 219 painters and 1095 matched controls registered by the Danish Contact Dermatitis Group between 2001 and 2010 were analysed. Results. Hand eczema (p contact dermatitis (p

  8. High-precision drop shape analysis on inclining flat surfaces: introduction and comparison of this special method with commercial contact angle analysis.

    Science.gov (United States)

    Schmitt, Michael; Heib, Florian

    2013-10-07

    Drop shape analysis is one of the most important and frequently used methods to characterise surfaces in the scientific and industrial communities. An especially large number of studies, which use contact angle measurements to analyse surfaces, are characterised by incorrect or misdirected conclusions such as the determination of surface energies from poorly performed contact angle determinations. In particular, the characterisation of surfaces, which leads to correlations between the contact angle and other effects, must be critically validated for some publications. A large number of works exist concerning the theoretical and thermodynamic aspects of two- and tri-phase boundaries. The linkage between theory and experiment is generally performed by an axisymmetric drop shape analysis, that is, simulations of the theoretical drop profiles by numerical integration onto a number of points of the drop meniscus (approximately 20). These methods work very well for axisymmetric profiles such as those obtained by pendant drop measurements, but in the case of a sessile drop onto real surfaces, additional unknown and misunderstood effects on the dependence of the surface must be considered. We present a special experimental and practical investigation as another way to transition from experiment to theory. This procedure was developed to be especially sensitive to small variations in the dependence of the dynamic contact angle on the surface; as a result, this procedure will allow the properties of the surface to be monitored with a higher precession and sensitivity. In this context, water drops onto a 111 silicon wafer are dynamically measured by video recording and by inclining the surface, which results in a sequence of non-axisymmetric drops. The drop profiles are analysed by commercial software and by the developed and presented high-precision drop shape analysis. In addition to the enhanced sensitivity for contact angle determination, this analysis technique, in

  9. [Contact allergic gastritis : Rare manifestation of a metal allergy].

    Science.gov (United States)

    Pföhler, C; Vogt, T; Müller, C S L

    2016-05-01

    Only a few cases of contact allergic gastritis in patients with nickel allergy have been reported in the literature. We report a case of probable contact-allergic gastritis in a 46-year-old woman. Clinical examination revealed lichenoid mucosal lesions of the gums adjacent to a bridge and crowns that had been implanted several weeks previously. Since implantation, the patient suffered from gastrointestinal complaints including stomach pain. Gastroscopy and histological investigation of stomach biopsies showed eosinophilic gastritis. Patch testing done under the diagnosis of contact allergic stomatitis showed positive reactions to gold sodium thiosulphate, manganese (II) chloride, nickel (II) sulphate, palladium chloride, vanadium (III) chloride, zirconium (IV) chloride, and fragrances. The crowns and the bridge contained gold, palladium, and zirconium, hence they were replaced by titan-based dentition. Shortly after replacing the artificial dentition, all gastrointestinal symptoms resolved spontaneously without further treatment. Delayed-type allergy to components in the artificial dentition seem to have caused the gastritis.

  10. Large deformation frictional contact analysis with immersed boundary method

    Science.gov (United States)

    Navarro-Jiménez, José Manuel; Tur, Manuel; Albelda, José; Ródenas, Juan José

    2018-01-01

    This paper proposes a method of solving 3D large deformation frictional contact problems with the Cartesian Grid Finite Element Method. A stabilized augmented Lagrangian contact formulation is developed using a smooth stress field as stabilizing term, calculated by Zienckiewicz and Zhu Superconvergent Patch Recovery. The parametric definition of the CAD surfaces (usually NURBS) is considered in the definition of the contact kinematics in order to obtain an enhanced measure of the contact gap. The numerical examples show the performance of the method.

  11. European Surveillance System on Contact Allergies (ESSCA)

    DEFF Research Database (Denmark)

    Uter, W; Amario-Hita, J C; Balato, A

    2017-01-01

    BACKGROUND: Contact allergy is a common condition and can severely interfere with daily life or professional activities. Due to changes in exposures, such as introduction of new substances, new products or formulations and regulatory intervention, the spectrum of contact sensitization changes....... OBJECTIVE: To evaluate the current spectrum of contact allergy to allergens present in the European baseline series (EBS) across Europe. METHODS: Retrospective analysis of data collected by the European Surveillance System on Contact Allergies (ESSCA, www.essca-dc.org) in consecutively patch-tested patients......, 2013/14, in 46 departments in 12 European countries. RESULTS: Altogether, 31 689 patients were included in the analysis. Compared to a similar analysis in 2004, the prevalence of contact allergy to methylisothiazolinone went up to around 20% in several departments. In comparison, contact allergy...

  12. Numerical analysis of the non-contacting gas face seals

    Science.gov (United States)

    Blasiak, S.

    2017-08-01

    The non-contacting gas face seals are used in high-performance devices where the main requirements are safety and reliability. Compliance with these requirements is made possible by careful research and analysis of physical processes related to, inter alia, fluid flow through the radial gap and ring oscillations susceptible to being housed in the enclosure under the influence of rotor kinematic forces. Elaborating and developing mathematical models describing these phenomena allows for more and more accurate analysis results. The paper presents results of studies on stationary ring oscillations made of different types of materials. The presented results of the research allow to determine which of the materials used causes the greatest amplitude of the vibration of the system fluid film-working rings.

  13. Contact mechanics: contact area and interfacial separation from small contact to full contact

    International Nuclear Information System (INIS)

    Yang, C; Persson, B N J

    2008-01-01

    We present a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. The numerical calculations mainly focus on the contact area and the interfacial separation from small contact (low load) to full contact (high load). For a small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For a high load the contact area approaches the nominal contact area (i.e. complete contact), and the interfacial separation approaches zero. The numerical results have been compared with analytical theory and experimental results. They are in good agreement with each other. The present findings may be very important for soft solids, e.g. rubber, or for very smooth surfaces, where complete contact can be reached at moderately high loads without plastic deformation of the solids

  14. Computerized Modeling and Loaded Tooth Contact Analysis of Hypoid Gears Manufactured by Face Hobbing Process

    Science.gov (United States)

    Nishino, Takayuki

    The face hobbing process has been widely applied in automotive industry. But so far few analytical tools have been developed. This makes it difficult for us to optimize gear design. To settle this situation, this study aims at developing a computerized tool to predict the running performances such as loaded tooth contact pattern, static transmission error and so on. First, based upon kinematical analysis of a cutting machine, a mathematical description of tooth surface generation is given. Second, based upon the theory of gearing and differential geometry, conjugate tooth surfaces are studied. Then contact lines are generated. Third, load distribution along contact lines is formulated. Last, the numerical model is validated by measuring loaded transmission error and loaded tooth contact pattern.

  15. PyContact: Rapid, Customizable, and Visual Analysis of Noncovalent Interactions in MD Simulations.

    Science.gov (United States)

    Scheurer, Maximilian; Rodenkirch, Peter; Siggel, Marc; Bernardi, Rafael C; Schulten, Klaus; Tajkhorshid, Emad; Rudack, Till

    2018-02-06

    Molecular dynamics (MD) simulations have become ubiquitous in all areas of life sciences. The size and model complexity of MD simulations are rapidly growing along with increasing computing power and improved algorithms. This growth has led to the production of a large amount of simulation data that need to be filtered for relevant information to address specific biomedical and biochemical questions. One of the most relevant molecular properties that can be investigated by all-atom MD simulations is the time-dependent evolution of the complex noncovalent interaction networks governing such fundamental aspects as molecular recognition, binding strength, and mechanical and structural stability. Extracting, evaluating, and visualizing noncovalent interactions is a key task in the daily work of structural biologists. We have developed PyContact, an easy-to-use, highly flexible, and intuitive graphical user interface-based application, designed to provide a toolkit to investigate biomolecular interactions in MD trajectories. PyContact is designed to facilitate this task by enabling identification of relevant noncovalent interactions in a comprehensible manner. The implementation of PyContact as a standalone application enables rapid analysis and data visualization without any additional programming requirements, and also preserves full in-program customization and extension capabilities for advanced users. The statistical analysis representation is interactively combined with full mapping of the results on the molecular system through the synergistic connection between PyContact and VMD. We showcase the capabilities and scientific significance of PyContact by analyzing and visualizing in great detail the noncovalent interactions underlying the ion permeation pathway of the human P2X 3 receptor. As a second application, we examine the protein-protein interaction network of the mechanically ultrastable cohesin-dockering complex. Copyright © 2017 Biophysical Society

  16. Unified Analysis of Multi-Chamber Contact Tanks and Mixing Efficiency Based on Vorticity Field. Part I: Hydrodynamic Analysis

    Directory of Open Access Journals (Sweden)

    Ender Demirel

    2016-11-01

    Full Text Available Multi-chamber contact tanks have been extensively used in industry for water treatment to provide potable water to communities, which is essential for human health. To evaluate the efficiency of this treatment process, flow and tracer transport analysis have been used in the literature using Reynolds averaged Navier–Stokes (RANS and large-eddy simulations (LES. The purpose of this study is two-fold. First a unifying analysis of the flow field is presented and similarities and differences in the numerical results that were reported in the literature are discussed. Second, the vorticity field is identified as the key parameter to use in separating the mean flow (jet zone and the recirculating zones. Based on the concepts of vorticity gradient and flexion product, it is demonstrated that the separation of the recirculation zone and the jet zone, fluid-fluid flow separation, is possible. The separation of the recirculation zones and vortex core lines are characterized using the definition of the Lamb vector. The separated regions are used to characterize the mixing efficiency in the chambers of the contact tank. This analysis indicates that the recirculation zone and jet zone formation are three-dimensional and require simulations over a long period of time to reach stability. It is recognized that the characteristics of the jet zones and the recirculation zones are distinct for each chamber and they follow a particular pattern and symmetry between the alternating chambers. Hydraulic efficiency coefficients calculated for each chamber show that the chambers having an inlet adjacent to the free surface may be designed to have larger volumes than the chambers having wall bounded inlets to improve the efficiency of the contact tank. This is a simple design alternative that would increase the efficiency of the system. Other observations made through the chamber analysis are also informative in redefining the characteristics of the efficiency of the

  17. First contact diagnosis and management of contact lens-related complications.

    Science.gov (United States)

    Fagan, Xavier J; Jhanji, Vishal; Constantinou, Marios; Amirul Islam, F M; Taylor, Hugh R; Vajpayee, Rasik B

    2012-08-01

    To describe the spectrum of contact lens-related problems in cases presenting to a tertiary referral eye hospital. A retrospective case record analysis of 111 eyes of 97 consecutive patients was undertaken over a period of five months at the Royal Victorian Eye and Ear Hospital, Melbourne, Australia. Contact lens-related complications (CLRC) were classified into microbial keratitis, sterile corneal infiltrates, corneal epitheliopathy and contact lens-related red eye (CLARE). Main parameters examined were nature of the first contact, clinical diagnosis, and management pattern. Forty-two percent of the initial presentations were to health care practitioners (HCPs) other than ophthalmologists. Mean duration from the onset of symptoms to presentation was 6.3 ± 10.9 days. Forty-nine percent (n = 54) of patients had an associated risk factor, most commonly overnight use of contact lenses (n = 14, 13 %). Most common diagnosis at presentation was corneal epitheliopathy (68 %) followed by sterile infiltrates (10 %), CLARE (8 %) and microbial keratitis (6 %). No significant differences were found in the pattern of treatment modalities administered by ophthalmologists and other HCPs. HCPs other than ophthalmologists are the first contact for contact lens-related problems in a significant proportion of patients. These HCPs manage the majority of CLRC by direct treatment or immediate referral.

  18. DUPIC fuel irradiation test and performance evaluation; the performance analysis of pellet-cladding contact fuel

    Energy Technology Data Exchange (ETDEWEB)

    Ho, K. I.; Kim, H. M.; Yang, K. B.; Choi, S. J. [Suwon University, Whasung (Korea)

    2002-04-01

    Thermal and mechanical models were reviewed, and selected for the analysis of nuclear fuel performance in reactor. 2 dimensional FEM software was developed. Thermal models-gap conductances, thermal conductivity of pellets, fission gas release, temperature distribution-were set and packaged into a software. Both thermal and mechanical models were interrelated to each other, and the final results, fuel performance during irradiation is obtained by iteration calculation. Also, the contact phenomena between pellet and cladding was analysed by mechanical computer software which was developed during this work. dimensional FEM program was developed which estimate the mechanical behavior and the thermal behaviors of nuclear fuel during irradiation. Since there is a importance during the mechanical deformation analysis in describing pellet-cladding contact phenomena, simplified 2 dimensional calculation method is used after the contact. The estimation of thermal fuel behavior during irradiation was compared with the results of other. 8 refs., 17 figs. (Author)

  19. Synthesis, structural characterization, Hirshfeld surface analysis and spectroscopic studies of cadmium (II) chloride complex with 4-hydroxy-1-methylpiperidine

    Energy Technology Data Exchange (ETDEWEB)

    Soudani, S. [Université de Carthage, Laboratoire de Chimie des Matériaux, Faculté des Sciences de Bizerte, 7021 Zarzouna (Tunisia); Ferretti, V. [Department of Chemical and Pharmaceutical Sciences and Center for Structural Diffractometry, via Fossato di Mortara 17, I-44121 Ferrara (Italy); Jelsch, C. [CRM2, CNRS, Institut Jean Barriol, Université de Lorraine, Vandoeuvre les Nancy CEDEX (France); Lefebvre, F. [Laboratoire de Chimie Organométallique de Surface (LCOMS), Ecole Supérieure de Chimie Physique Electronique, 69626 Villeurbanne Cedex (France); Nasr, C. Ben, E-mail: cherif_bennasr@yahoo.fr [Université de Carthage, Laboratoire de Chimie des Matériaux, Faculté des Sciences de Bizerte, 7021 Zarzouna (Tunisia)

    2016-05-15

    The chemical preparation, crystal structure, Hirshfeld surface analysis and spectroscopic characterization of the novel cadmium (II) 4-hydroxy-1-methylpiperidine complex, Cd{sub 4}Cl{sub 10}(C{sub 6}H{sub 14}NO){sub 2}·2H{sub 2}O, have been reported. The atomic arrangement can be described as built up by an anionic framework, formed by edge sharing CdCl{sub 6} and CdCl{sub 5}O octahedral linear chains spreading along the a-axis. These chains are interconnected by water molecules via O–H⋯Cl and O–H⋯O hydrogen bonds to form layers parallel to (011) plane. The organic cations are inserted between layers through C–H⋯Cl hydrogen bonds. Investigation of intermolecular interactions and crystal packing via Hirshfeld surface analysis reveals that the H{sub C}⋯Cl and H{sub C}⋯H{sub C} intermolecular interactions are the most abundant contacts of the organic cation in the crystal packing. The statistical analysis of crystal contacts reveals the driving forces in the packing formation. The {sup 13}C and {sup 15}N CP-MAS NMR spectra are in agreement with the X-ray structure. The vibrational absorption bands were identified by infrared spectroscopy. DFT calculations allowed the attribution of the NMR peaks and of the IR bands.

  20. Preparation of chitosan/amine modified diatomite composites and adsorption properties of Hg(II) ions.

    Science.gov (United States)

    Fu, Yong; Huang, Yue; Hu, Jianshe; Zhang, Zhengjie

    2018-03-01

    A green functional adsorbent (CAD) was prepared by Schiff base reaction of chitosan and amino-modified diatomite. The morphology, structure and adsorption properties of the CAD were characterized by Fourier transform infrared spectroscopy, thermogravimetric analysis, scanning electron microscopy and Brunauer Emmett Teller measurements. The effect of pH value, contact time and temperature on the adsorption of Hg(II) ions for the CAD is discussed in detail. The experimental results showed that the CAD had a large specific surface area and multifunctional groups such as amino, hydroxyl and Schiff base. The optimum adsorption effect was obtained when the pH value, temperature and contact time were 4, 25 °C and 120 min, respectively, and the corresponding maximum adsorption capacity of Hg(II) ions reached 102 mg/g. Moreover, the adsorption behavior of Hg(II) ions for the CAD followed the pseudo-second-order kinetic model and Langmuir model. The negative ΔG 0 and ΔH 0 suggested that the adsorption was a spontaneous exothermic process.

  1. High-precision drop shape analysis (HPDSA) of quasistatic contact angles on silanized silicon wafers with different surface topographies during inclining-plate measurements: Influence of the surface roughness on the contact line dynamics

    International Nuclear Information System (INIS)

    Heib, F.; Hempelmann, R.; Munief, W.M.; Ingebrandt, S.; Fug, F.; Possart, W.; Groß, K.; Schmitt, M.

    2015-01-01

    Highlights: • Analysis of the triple line motion on surfaces with nanoscale surface topographies. • Analysis of the triple line motion is performed in sub-pixel resolution. • A special fitting and statistical approach for contact angle analysis is applied. • The analyses result set of contact angle data which is independent of “user-skills”. • Characteristically density distributions in dependence on the surface properties. - Abstract: Contact angles and wetting of solid surfaces are strongly influenced by the physical and chemical properties of the surfaces. These influence quantities are difficult to distinguish from each other if contact angle measurements are performed by measuring only the advancing θ a and the receding θ r contact angle. In this regard, time-dependent water contact angles are measured on two hydrophobic modified silicon wafers with different physical surface topographies. The first surface is nearly atomically flat while the second surface is patterned (alternating flat and nanoscale rough patterns) which is synthesized by a photolithography and etching procedure. The different surface topographies are characterized with atomic force microscopy (AFM), Fourier transform infrared reflection absorption spectroscopy (FTIRRAS) and Fourier transform infrared attenuated total reflection spectroscopy (FTIR-ATR). The resulting set of contact angle data obtained by the high-precision drop shape analysis approach is further analyzed by a Gompertzian fitting procedure and a statistical counting procedure in dependence on the triple line velocity. The Gompertzian fit is used to analyze overall properties of the surface and dependencies between the motion on the front and the back edge of the droplets. The statistical counting procedure results in the calculation of expectation values E(p) and standard deviations σ(p) for the inclination angle φ, contact angle θ, triple line velocity vel and the covered distance of the triple line dis

  2. High-precision drop shape analysis (HPDSA) of quasistatic contact angles on silanized silicon wafers with different surface topographies during inclining-plate measurements: Influence of the surface roughness on the contact line dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Heib, F., E-mail: f.heib@mx.uni-saarland.de [Department of Physical Chemistry, Saarland University, 66123 Saarbrücken (Germany); Hempelmann, R. [Department of Physical Chemistry, Saarland University, 66123 Saarbrücken (Germany); Munief, W.M.; Ingebrandt, S. [Department of Informatics and Microsystem Technology, University of Applied Sciences, Kaiserslautern, 66482 Zweibrücken (Germany); Fug, F.; Possart, W. [Department of Adhesion and Interphases in Polymers, Saarland University, 66123 Saarbrücken (Germany); Groß, K.; Schmitt, M. [Department of Physical Chemistry, Saarland University, 66123 Saarbrücken (Germany)

    2015-07-01

    Highlights: • Analysis of the triple line motion on surfaces with nanoscale surface topographies. • Analysis of the triple line motion is performed in sub-pixel resolution. • A special fitting and statistical approach for contact angle analysis is applied. • The analyses result set of contact angle data which is independent of “user-skills”. • Characteristically density distributions in dependence on the surface properties. - Abstract: Contact angles and wetting of solid surfaces are strongly influenced by the physical and chemical properties of the surfaces. These influence quantities are difficult to distinguish from each other if contact angle measurements are performed by measuring only the advancing θ{sub a} and the receding θ{sub r} contact angle. In this regard, time-dependent water contact angles are measured on two hydrophobic modified silicon wafers with different physical surface topographies. The first surface is nearly atomically flat while the second surface is patterned (alternating flat and nanoscale rough patterns) which is synthesized by a photolithography and etching procedure. The different surface topographies are characterized with atomic force microscopy (AFM), Fourier transform infrared reflection absorption spectroscopy (FTIRRAS) and Fourier transform infrared attenuated total reflection spectroscopy (FTIR-ATR). The resulting set of contact angle data obtained by the high-precision drop shape analysis approach is further analyzed by a Gompertzian fitting procedure and a statistical counting procedure in dependence on the triple line velocity. The Gompertzian fit is used to analyze overall properties of the surface and dependencies between the motion on the front and the back edge of the droplets. The statistical counting procedure results in the calculation of expectation values E(p) and standard deviations σ(p) for the inclination angle φ, contact angle θ, triple line velocity vel and the covered distance of the triple

  3. [Comparative pressure measurements with the non-contact tonometer and the Goldmann applanation tonometer].

    Science.gov (United States)

    Langmann, G; Schuhmann, G; Schwaiger, W

    1985-11-01

    The intraocular pressure of 400 patients was measured with both the Non-Contact Tonometer II (NCT II) and the Goldmann applanation tonometer (GAT) and was statistically evaluated. The clinical experience gained, as well as advantages and limitations in application, are discussed.

  4. Patch tests with fragrance mix II and its components.

    Science.gov (United States)

    Pónyai, Györgyi; Németh, Ilona; Altmayer, Anita; Nagy, Gabriella; Irinyi, Beatrix; Battyáni, Zita; Temesvári, Erzsébet

    2012-01-01

    Fragrance mix II (FM II) was initiated to detect contact hypersenstitivity (CH) to fragrances that could not have been identified previously. The aim of this multicenter study was to map the frequency of CH to FM II and its components in Hungary. Six centers participated in the survey from 2009 to 2010. A total off 565 patients (434 women and 131 men) with former skin symptoms provoked by scented products were patch tested. The tests were performed with Brial GmbH D-Greven allergens. In the environmental patch test series, FM II, FM I, Myroxylon pereirae, colophonium, wood-tar mix, propolis, and sesquiterpene lactone mix were tested as fragrance allergens. The FM II components (citral, farnesol, coumarin, citronellol, α-hexyl-cinnamaldehyde, and hydroxy-isohexyl-3-cyclohexene-carboxaldehyde [Lyral]) were also tested. Contact hypersenstitivity to any fragrances was detected in 28.8%, to FM II in 17.2% of the patients. Contact hypersenstitivity to hydroxy-isohexyl-3-cyclohexene-carboxaldehyde was observed in 7.3%, to coumarin in 5.1%, to α-hexyl-cinnamaldehyde in 3.5%, to citral in 3.4%, to farnesol in 2.5%, and to citronellol in 1.2%. Of the FM II-positive cases, 48.4% showed isolated CH reaction. The frequency of CH to FM II is 17.2% in the tested, selected Hungarian population. The CH to FM II and its components could not have been revealed without the present test materials.

  5. Schottky contact analysis of photovoltaic chalcopyrite thin film absorbers

    International Nuclear Information System (INIS)

    Schlenker, E.; Mertens, V.; Parisi, J.; Reineke-Koch, R.; Koentges, M.

    2007-01-01

    Current-voltage and capacitance-voltage measurements serve to analyze thermally evaporated Al Schottky contacts on Cu(In, Ga)Se 2 based photovoltaic thin film devices, either taken as grown or etched in a bromine-methanol solution. The characteristics of the Schottky contacts on the as-grown films give evidence for some dielectric layer developing between the metal and the semiconductor. Etching the semiconductor surface prior to evaporation of the Al front contact yields a pure metal-semiconductor behavior, including effects that can be attributed to an additional diode at the Mo contact. Simulations confirm the experimental results

  6. Atomic force microscopy and scanning electron microscopy analysis of daily disposable limbal ring contact lenses.

    Science.gov (United States)

    Lorenz, Kathrine Osborn; Kakkassery, Joseph; Boree, Danielle; Pinto, David

    2014-09-01

    Limbal ring (also known as 'circle') contact lenses are becoming increasingly popular, especially in Asian markets because of their eye-enhancing effects. The pigment particles that give the eye-enhancing effects of these lenses can be found on the front or back surface of the contact lens or 'enclosed' within the lens matrix. The purpose of this research was to evaluate the pigment location and surface roughness of seven types of 'circle' contact lenses. Scanning electron microscopic (SEM) analysis was performed using a variable pressure Hitachi S3400N instrument to discern the placement of lens pigments. Atomic force microscopy (Dimension Icon AFM from Bruker Nano) was used to determine the surface roughness of the pigmented regions of the contact lenses. Atomic force microscopic analysis was performed in fluid phase under contact mode using a Sharp Nitride Lever probe (SNL-10) with a spring constant of 0.06 N/m. Root mean square (RMS) roughness values were analysed using a generalised linear mixed model with a log-normal distribution. Least square means and their corresponding 95% confidence intervals were estimated for each brand, location and pigment combination. SEM cross-sectional images at 500× and 2,000× magnification showed pigment on the surface of six of the seven lens types tested. The mean depth of pigment for 1-DAY ACUVUE DEFINE (1DAD) lenses was 8.1 μm below the surface of the lens, while the remaining lens types tested had pigment particles on the front or back surface. Results of the atomic force microscopic analysis indicated that 1DAD lenses had significantly lower root mean square roughness values in the pigmented area of the lens than the other lens types tested. SEM and AFM analysis revealed pigment on the surface of the lens for all types tested with the exception of 1DAD. Further research is required to determine if the difference in pigment location influences on-eye performance. © 2014 The Authors. Clinical and Experimental

  7. A finite element method with contact for tensile analysis in fuel rods

    International Nuclear Information System (INIS)

    Tanajura, C.A.S.; Galeao, A.C.N.R.

    1987-01-01

    Elements for mechanical analysis of fuel rod of a PWR type reactor, are presented. The rod, consists basically in a cylindrical coating of zircalloy which contains pilling of UO 2 pellets, is submitted to strong internal and external pressures, intense temperature gradients and neutron flux. These conditions lead several phenomena in the pellet (swelling, fracture, densification, creep) and in the cladding (embrittlement, corrosion, creep) which undergo deformations leading them to contact the restriction for the interpenetration is included in the problem without restriction by Lagrange multipliers. Considering a non-linear problem, due to the surface of contact to be not known a priori, the numerical solutions were obtained using the finite element method. (M.C.K.) [pt

  8. Occupational irritant contact dermatitis diagnosed by analysis of contact irritants and allergens in the work environment

    DEFF Research Database (Denmark)

    Friis, Ulrik F; Menné, Torkil; Schwensen, Jakob F

    2014-01-01

    BACKGROUND: Irritant contact dermatitis (ICD) is a common diagnosis in patients with occupational contact dermatitis (OCD). Studies are lacking on the usefulness of material safety data sheets (MSDSs) in making the diagnosis of ICD. OBJECTIVE: To characterize irritant exposures leading...... to the diagnosis of occupational ICD (OICD), and to evaluate the occurrence of concomitant exposures to contact allergens. METHODS: We included 316 patients with suspected occupational hand dermatitis, referred to the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte, Denmark during......), mechanical traumas (n = 19), and oils (n = 15). Exposure to specific irritant chemicals was found in 9 patients, and was identified from MSDSs/ingredients labelling in 8 of these patients. Review of MSDSs and ingredients labelling showed that 41 patients were exposed to 41 moderate to potent contact...

  9. Bis{4-methylbenzyl 2-[4-(propan-2-ylbenzylidene]hydrazinecarbodithioato-κ2N2,S}nickel(II: crystal structure and Hirshfeld surface analysis

    Directory of Open Access Journals (Sweden)

    Enis Nadia Md Yusof

    2017-03-01

    Full Text Available The complete molecule of the title hydrazine carbodithioate complex, [Ni(C19H21N2S22], is generated by the application of a centre of inversion. The NiII atom is N,S-chelated by two hydrazinecarbodithioate ligands, which provide a trans-N2S2 donor set that defines a distorted square-planar geometry. The conformation of the five-membered chelate ring is an envelope with the NiII atom being the flap atom. In the crystal, p-tolyl-C—H...π(benzene-iPr, iPr-C—H...π(p-tolyl and π–π interactions [between p-tolyl rings with inter-centroid distance = 3.8051 (12 Å] help to consolidate the three-dimensional architecture. The analysis of the Hirshfeld surface confirms the importance of H-atom contacts in establishing the packing.

  10. Clinical update on contact allergy

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Johansen, Jeanne Duus; Orton, David I

    2005-01-01

    PURPOSE OF REVIEW: The aim of this article is to review recent findings in contact allergy, regarding clinical research. RECENT FINDINGS: The biocide methyldibromo glutaronitrile was identified to be an important sensitizer. Subsequently, it was banned from leave-on cosmetics in the European Union....... Another group of important allergens that have been studied extensively included the fragrances oak moss absolute, isoeugenol, hydroxyisohexyl 3-cyclohexene carboxaldehyde and farnesol. A new fragrance mix II has been developed for standard testing, which includes the two latter compounds. Dose response...... a classification of newly introduced chemicals; increasingly, the local lymph node assay is supplementing and potentially replacing the guinea pig maximization test. Recent advances in occupational contact allergy include, for example, some attempts to improve diagnostics for epoxy resin and other plastic, glue...

  11. Combining Stochastic Deformation/Relaxation and Intermolecular Contacts Analysis for Extracting Pharmacophores from Ligand-Receptor Complexes.

    Science.gov (United States)

    Hatmal, Ma'mon M; Taha, Mutasem O

    2018-04-23

    We previously combined molecular dynamics (classical or simulated annealing) with ligand-receptor contacts analysis as a means to extract valid pharmacophore model(s) from single ligand-receptor complexes. However, molecular dynamics methods are computationally expensive and time-consuming. Here we describe a novel method for extracting valid pharmacophore model(s) from a single crystallographic structure within a reasonable time scale. The new method is based on ligand-receptor contacts analysis following energy relaxation of a predetermined set of randomly deformed complexes generated from the targeted crystallographic structure. Ligand-receptor contacts maintained across many deformed/relaxed structures are assumed to be critical and used to guide pharmacophore development. This methodology was implemented to develop valid pharmacophore models for PI3K-γ, RENIN, and JAK1. The resulting pharmacophore models were validated by receiver operating characteristic (ROC) analysis against inhibitors extracted from the CHEMBL database. Additionally, we implemented pharmacophores extracted from PI3K-γ to search for new inhibitors from the National Cancer Institute list of compounds. The process culminated in new PI3K-γ/mTOR inhibitory leads of low micromolar IC 50 s.

  12. Evaluation of sorption capacity of scrap tyre in the removal of copper (II) ion from aqua system

    International Nuclear Information System (INIS)

    Oladoja, N.A.; Ofomaja, A.; Ebare, E.; Ebare, E.

    2006-01-01

    The use of scrap-tyre (ST), which was both a waste and pollutant was investigated as a low-cost sorbent to sorbed Cu (II) from aqueous solution. The influence of pH, sorbent dosage, contact time, and initial sorbate concentration on the uptake of Cu (II) by ST were studied. Optimum sorption of Cu (II) by ST was achieved at pH 6. The amount Of sorbate sorbed per gram of sorbent decreased with increase in sorbent dosage. Maximum uptake of the Cu (II) was achieved within the first thirty minutes of contact between the ST and the Cu (II). The equilibrium relationship between the concentration of the Cu (II) in the fluid phase and the concentration in the ST particles at a given temperature showed that the sorption mechanism was like adsorption rather than distribution into any phase. Analysis of the result using Langmuir and Freundlich models showed that it conformed to Langmuir equation based on the formation of a monomolecular layer. The adsorption capacity due to monolayer coverage was 12.95 mg/g, while the energy of adsorption was 3.95 dm/mg. (author)

  13. Forensic Analysis of a Contact Lens in a Murder Case.

    Science.gov (United States)

    Zwerling, Charles S

    2016-03-01

    Contact lenses have had rare relevance in trials and/or investigations. After 5 years of burial, orbital remnants were retrieved from an exhumed body and subsequently identified as a key piece of material evidence in a murder trial. The exhumed case materials were evaluated under laboratory conditions and were determined to be contact lens remnants. Contact lens fracture and burial simulation studies were performed to provide additional corroboration of the physical findings of the exhumed contact lens remnants. This material evidence was instrumental in providing factual proof refuting the defendant's testimony in the murder trial. A brief history of contact lens composition and use is provided for understanding the methods and observational results. This forensic case study represents the first published documentation of a contact lens from an exhumed body being used in a murder investigation and establishes an operational procedure for future forensic contact lens examinations. © 2016 American Academy of Forensic Sciences.

  14. Nonlinear Equilibrium and Stability Analysis of Axially Loaded Piles Under Bilateral Contact Constraints

    Directory of Open Access Journals (Sweden)

    Ricardo A. da Mota Silveira

    Full Text Available AbstractThis paper presents a nonlinear stability analysis of piles under bilateral contact constraints imposed by a geological medium (soil or rock. To solve this contact problem, the paper proposes a general numerical methodology, based on the finite element method (FEM. In this context, a geometrically nonlinear beam-column element is used to model the pile while the geological medium can be idealized as discrete (spring or continuum (Winkler and Pasternak foundation elements. Foundation elements are supposed to react under tension and compression, so during the deformation process the structural elements are subjected to bilateral contact constraints. The errors along the equilibrium paths are minimized and the convoluted nonlinear equilibrium paths are made traceable through the use of an updated Lagrangian formulation and a Newton-Raphson scheme working with the generalized displacement technique. The study offers stability analyses of three problems involving piles under bilateral contact constraints. The analyses show that in the evaluation of critical loads a great influence is wielded by the instability modes. Also, the structural system stiffness can be highly influenced by the representative model of the soil.

  15. Differentiating allergic and irritant contact dermatitis by high-definition optical coherence tomography

    DEFF Research Database (Denmark)

    Boone, Marc A L M; Jemec, Gregor B E; Del Marmol, V

    2015-01-01

    Differentiation of allergic contact dermatitis (ACD) and irritant contact dermatitis (ICD) is important because of different management requirements. Various non-invasive tests have been used in an attempt to improve diagnosis. In irritant dermatitis, thickening of the epidermis has been a constant...... was threefold. (1) To evaluate the correlation between HD-OCT features and clinical scores of allergic and irritant patch test reactions. (2) To explore the potential of HD-OCT in optimizing the visual patch test scoring. (3) To assess in vivo the cytological and 3-D micro-architectural differences in skin...... reaction types between doubtful positive ACD and ICD. Twenty-two volunteers were patch tested using potassium(VI)dichromate, cobalt(II)chloride, nickel(II) sulfate and palladium(II)chloride. Visual patch test scoring and HD-OCT assisted patch test scoring were performed at 48 and 96 h after patch test...

  16. Contact-impact algorithms on parallel computers

    International Nuclear Information System (INIS)

    Zhong Zhihua; Nilsson, Larsgunnar

    1994-01-01

    Contact-impact algorithms on parallel computers are discussed within the context of explicit finite element analysis. The algorithms concerned include a contact searching algorithm and an algorithm for contact force calculations. The contact searching algorithm is based on the territory concept of the general HITA algorithm. However, no distinction is made between different contact bodies, or between different contact surfaces. All contact segments from contact boundaries are taken as a single set. Hierarchy territories and contact territories are expanded. A three-dimensional bucket sort algorithm is used to sort contact nodes. The defence node algorithm is used in the calculation of contact forces. Both the contact searching algorithm and the defence node algorithm are implemented on the connection machine CM-200. The performance of the algorithms is examined under different circumstances, and numerical results are presented. ((orig.))

  17. Stability analysis of rough surfaces in adhesive normal contact

    Science.gov (United States)

    Rey, Valentine; Bleyer, Jeremy

    2018-03-01

    This paper deals with adhesive frictionless normal contact between one elastic flat solid and one stiff solid with rough surface. After computation of the equilibrium solution of the energy minimization principle and respecting the contact constraints, we aim at studying the stability of this equilibrium solution. This study of stability implies solving an eigenvalue problem with inequality constraints. To achieve this goal, we propose a proximal algorithm which enables qualifying the solution as stable or unstable and that gives the instability modes. This method has a low computational cost since no linear system inversion is required and is also suitable for parallel implementation. Illustrations are given for the Hertzian contact and for rough contact.

  18. Analysis of Tire Contact Parameters Using Visual Processing

    Directory of Open Access Journals (Sweden)

    Valentin Ivanov

    2010-01-01

    The first part of this paper presents the results of experimental estimation of the contact patch area depending on the normal wheel load and inflation pressure for different car tires. The data were obtained for test bench conditions on the basis of the visual processing of tread footprint. Further, the contact length in the cohesion area during wheel rolling for single points on the tire profile has been chosen as a benchmark criterion. This paper has analyzed the influence of the wheel normal load and tire inflation pressure on the contact length with small rolling velocities. The results of the investigations are given for winter and racing tires with different grades of wear.

  19. Crystal structure and Hirshfeld surface analysis of hexakis(μ-benzoato-κ2O:O′bis(pyridine-3-carbonitrile-κN1trizinc(II

    Directory of Open Access Journals (Sweden)

    Tuncer Hökelek

    2017-12-01

    Full Text Available The asymmetric unit of the title complex, [Zn3(C7H5O26(C6H4N22], contains one half of the complex molecule, i.e. one and a half ZnII cations, three benzoate (Bnz and one pyridine-3-carbonitrile (Cpy molecule; the Bnz anions act as bidentate ligands through the carboxylate O atoms, while the Cpy ligand acts as a monodentate N(pyridine-bonding ligand. The complete centrosymmetric trinuclear complex thus comprises a linear array of three ZnII cations. The central ZnII cation shows an octahedral coordination and is bridged to each of the terminal ZnII cations by three Bnz anions. By additional coordination of the CPy ligand, the terminal ZnII cations adopt a trigonal–pyramidal coordination environment. In the crystal, the Bnz anions link to the Cpy N atoms via weak C—H...N hydrogen bonds, forming a two-dimensional network. C—H...π and π–π interactions [between the benzene and pyridine rings of adjacent molecules with an intercentroid distance of 3.850 (4 Å] help to consolidate a three-dimensional architecture. The Hirshfeld surface analysis confirms the role of H-atom contacts in establishing the packing.

  20. Experimental and numerical investigation of contact-area-limited doping for top-contact pentacene thin-film transistors with Schottky contact.

    Science.gov (United States)

    Noda, Kei; Wada, Yasuo; Toyabe, Toru

    2015-10-28

    Effects of contact-area-limited doping for pentacene thin-film transistors with a bottom-gate, top-contact configuration were investigated. The increase in the drain current and the effective field-effect mobility was achieved by preparing hole-doped layers underneath the gold contact electrodes by coevaporation of pentacene and 2,3,5,6-tetrafluoro-7,7,8,8-tetracyanoquinodimethane (F4TCNQ), confirmed by using a thin-film organic transistor advanced simulator (TOTAS) incorporating Schottky contact with a thermionic field emission (TFE) model. Although the simulated electrical characteristics fit the experimental results well only in the linear regime of the transistor operation, the barrier height for hole injection and the gate-voltage-dependent hole mobility in the pentacene transistors were evaluated with the aid of the device simulation. This experimental data analysis with the simulation indicates that the highly-doped semiconducting layers prepared in the contact regions can enhance the charge carrier injection into the active semiconductor layer and concurrent trap filling in the transistor channel, caused by the mitigation of a Schottky energy barrier. This study suggests that both the contact-area-limited doping and the device simulation dealing with Schottky contact are indispensable in designing and developing high-performance organic thin-film transistors.

  1. Lifetime limitations of ohmic, contacting RF MEMS switches with Au, Pt and Ir contact materials due to accumulation of ‘friction polymer’ on the contacts

    International Nuclear Information System (INIS)

    Czaplewski, David A; Nordquist, Christopher D; Dyck, Christopher W; Patrizi, Gary A; Kraus, Garth M; Cowan, William D

    2012-01-01

    We present lifetime limitations and failure analysis of many packaged RF MEMS ohmic contacting switches with Au–Au, Au–Ir, and Au–Pt contact materials operating with 100 µN of contact force per contact in hermetically sealed glass wall packages. All metals were tested using the same switch design in a controlled environment to provide a comparison between the performance of the different materials and their corresponding failure mechanisms. The switch lifetimes of the different contact materials varied from several hundred cycles to 200 million cycles with different mechanisms causing failures for different contact materials. Switches with Au–Au contacts failed due to adhesion when thoroughly cleaned while switches with dissimilar metal contacts (Au–Ir and Au–Pt) operated without adhesion failures but failed due to carbon accumulation on the contacts even in a clean, packaged environment as a result of the catalytic behavior of the contact materials. Switch lifetimes correlated inversely with catalytic behavior of the contact metals. The data suggests the path to increase switch lifetime is to use favorable catalytic materials as contacts, design switches with higher contact forces to break through any residual contamination, and use cleaner, probably smaller, packages. (paper)

  2. Mapping allostery through computational glycine scanning and correlation analysis of residue-residue contacts.

    Science.gov (United States)

    Johnson, Quentin R; Lindsay, Richard J; Nellas, Ricky B; Fernandez, Elias J; Shen, Tongye

    2015-02-24

    Understanding allosteric mechanisms is essential for the physical control of molecular switches and downstream cellular responses. However, it is difficult to decode essential allosteric motions in a high-throughput scheme. A general two-pronged approach to performing automatic data reduction of simulation trajectories is presented here. The first step involves coarse-graining and identifying the most dynamic residue-residue contacts. The second step is performing principal component analysis of these contacts and extracting the large-scale collective motions expressed via these residue-residue contacts. We demonstrated the method using a protein complex of nuclear receptors. Using atomistic modeling and simulation, we examined the protein complex and a set of 18 glycine point mutations of residues that constitute the binding pocket of the ligand effector. The important motions that are responsible for the allostery are reported. In contrast to conventional induced-fit and lock-and-key binding mechanisms, a novel "frustrated-fit" binding mechanism of RXR for allosteric control was revealed.

  3. Spectroscopic, Elemental and Thermal Analysis, and Positron Annihilation Studies on Ca(II), Sr(II), Ba(II), Pb(II), and Fe(III) Penicillin G Potassium Complexes

    Science.gov (United States)

    Refat, M. S.; Sharshara, T.

    2015-11-01

    The [Pb(Pin)2] · 3H2O, [M(Pin)(H2O)2(Cl)] · nH2O (M = SrII, CaII or BaII; n = 0-1), and [Fe(Pin)2(Cl)(H2O)] · H2O penicillin G potassium (Pin) complexes were synthesized and characterized using elemental analyses, molar conductivity, thermal analysis and electronic spectroscopy techniques. The positron annihilation lifetime (PAL) and Doppler broadening (DB) techniques have been employed to probe the defects and structural changes of Pin ligand and its complexes. The PAL and DB line-shape parameters were discussed in terms of the structure, molecular weight, ligand-metal molar ratio, and other properties of the Pin complexes.

  4. Numerical Analysis of the Influence of Clearance on Stress State and Contact Pressure in Plain Bearings

    Directory of Open Access Journals (Sweden)

    Vasile Cojocaru

    2017-12-01

    Full Text Available In the analysis of plain bearings by finite element method it is important to model as closely to real state the aspects that influence the stress and contact pressure: the loading mode, the properties of the materials, the lubrication system, the clearance between the shaft and the bearing body, the evolution in time of clearance correlated with the wear, etc. In order to study the effect of the clearance on the stress state, a plain bearing with nominal diameter d=40 mm was modeled. The contact pressure and the equivalent stress were computed for six discrete values of clearance, range from c=0 to c=0.3 mm. It has been shown that the increase of clearance generates an increase of the equivalent stress and contact pressure. The growth rate is higher for contact pressure, due to the decrease of the contact surface between the shaft and the bearing body

  5. Isogeometric frictionless contact analysis with the third medium method

    Science.gov (United States)

    Kruse, R.; Nguyen-Thanh, N.; Wriggers, P.; De Lorenzis, L.

    2018-01-01

    This paper presents an isogeometric formulation for frictionless contact between deformable bodies, based on the recently proposed concept of the third medium. This concept relies on continuum formulations not only for the contacting bodies but also for a fictitious intermediate medium in which the bodies can move and interact. Key to the formulation is a suitable definition of the constitutive behavior of the third medium. In this work, based on a number of numerical tests, the role of the material parameters of the third medium is systematically assessed. We also assess the rate of spatial convergence for higher-order discretizations, stemming from the regularization of the non-smooth contact problem inherent to the third medium approach. Finally, problems with self contact are considered and turn out to be an attractive application of the method.

  6. Experimental analysis of the Schottky barrier height of metal contacts in black phosphorus field-effect transistors

    Science.gov (United States)

    Chang, Hsun-Ming; Fan, Kai-Lin; Charnas, Adam; Ye, Peide D.; Lin, Yu-Ming; Wu, Chih-I.; Wu, Chao-Hsin

    2018-04-01

    Compared to graphene and MoS2, studies on metal contacts to black phosphorus (BP) transistors are still immature. In this work, we present the experimental analysis of titanium contacts on BP based upon the theory of thermionic emssion. The Schottky barrier height (SBH) is extracted by thermionic emission methods to analyze the properties of Ti-BP contact. To examine the results, the band gap of BP is extracted followed by theoretical band alignment by Schottky-Mott rule. However, an underestimated SBH is found due to the hysteresis in electrical results. Hence, a modified SBH extraction for contact resistance that avoids the effects of hysteresis is proposed and demonstrated, showing a more accurate SBH that agrees well with theoretical value and results of transmission electron microscopy and energy-dispersive x-ray spectroscopy.

  7. Wildlife contact analysis: Emerging methods, questions, and challenges

    Science.gov (United States)

    Cross, Paul C.; Creech, Tyler G.; Ebinger, Michael R.; Heisey, Dennis M.; Irvine, Kathryn M.; Creel, Scott

    2012-01-01

    Recent technological advances, such as proximity loggers, allow researchers to collect complete interaction histories, day and night, among sampled individuals over several months to years. Social network analyses are an obvious approach to analyzing interaction data because of their flexibility for fitting many different social structures as well as the ability to assess both direct contacts and indirect associations via intermediaries. For many network properties, however, it is not clear whether estimates based upon a sample of the network are reflective of the entire network. In wildlife applications, networks may be poorly sampled and boundary effects will be common. We present an alternative approach that utilizes a hierarchical modeling framework to assess the individual, dyadic, and environmental factors contributing to variation in the interaction rates and allows us to estimate the underlying process variation in each. In a disease control context, this approach will allow managers to focus efforts on those types of individuals and environments that contribute the most toward super-spreading events. We account for the sampling distribution of proximity loggers and the non-independence of contacts among groups by only using contact data within a group during days when the group membership of proximity loggers was known. This allows us to separate the two mechanisms responsible for a pair not contacting one another: they were not in the same group or they were in the same group but did not come within the specified contact distance. We illustrate our approach with an example dataset of female elk from northwestern Wyoming and conclude with a number of important future research directions.

  8. Occupational irritant contact dermatitis diagnosed by analysis of contact irritants and allergens in the work environment.

    Science.gov (United States)

    Friis, Ulrik F; Menné, Torkil; Schwensen, Jakob F; Flyvholm, Mari-Ann; Bonde, Jens P E; Johansen, Jeanne D

    2014-12-01

    Irritant contact dermatitis (ICD) is a common diagnosis in patients with occupational contact dermatitis (OCD). Studies are lacking on the usefulness of material safety data sheets (MSDSs) in making the diagnosis of ICD. To characterize irritant exposures leading to the diagnosis of occupational ICD (OICD), and to evaluate the occurrence of concomitant exposures to contact allergens. We included 316 patients with suspected occupational hand dermatitis, referred to the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte, Denmark during January 2010-August 2011, in a programme consisting of a clinical examination, exposure assessment, and extensive patch/prick testing. OCD was diagnosed in 228 patients. Of these patients, 118 were diagnosed with OICD. The main irritant exposures identified were wet work (n = 64), gloves (n = 45), mechanical traumas (n = 19), and oils (n = 15). Exposure to specific irritant chemicals was found in 9 patients, and was identified from MSDSs/ingredients labelling in 8 of these patients. Review of MSDSs and ingredients labelling showed that 41 patients were exposed to 41 moderate to potent contact allergens, and 18 patients were exposed to 25 weak workplace contact allergens. In the present study, the systematic exposure assessment did not reveal any new irritants. MSDSs have a limited role in the investigation of ICD. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Shoe contact dermatitis from dimethyl fumarate: clinical manifestations, patch test results, chemical analysis, and source of exposure.

    Science.gov (United States)

    Giménez-Arnau, Ana; Silvestre, Juan Francisco; Mercader, Pedro; De la Cuadra, Jesus; Ballester, Isabel; Gallardo, Fernando; Pujol, Ramón M; Zimerson, Erik; Bruze, Magnus

    2009-11-01

    The methyl ester form of fumaric acid named dimethyl fumarate (DMF) is an effective mould-growth inhibitor. Its irritating and sensitizing properties were demonstrated in animal models. Recently, DMF has been identified as responsible for furniture contact dermatitis in Europe. To describe the clinical manifestations, patch test results, shoe chemical analysis, and source of exposure to DMF-induced shoe contact dermatitis. Patients with suspected shoe contact dermatitis were studied in compliance with the Declaration of Helsinki. Patch test results obtained with their own shoe and the European baseline series, acrylates and fumaric acid esters (FAE), were recorded according to international guidelines. The content of DMF in shoes was analysed with gas chromatography and mass spectrometry. Acute, immediate irritant contact dermatitis and non-immunological contact urticaria were observed in eight adults and two children, respectively. All the adult patients studied developed a delayed sensitization demonstrated by a positive patch testing to DMF Global preventive measures for avoiding contact with DMF are necessary.

  10. Combination of sawdust from teak wood and rice husk activated carbon as adsorbent of Pb(II) ion and its analysis using solid-phase spectrophotometry (sps)

    Science.gov (United States)

    Saputro, S.; Mahardiani, L.; Wulandari, D. A.

    2018-03-01

    This research aimed to know the usage of sawdust of teak wood and rice husk waste as Pb (II) ion adsorbents in simulated liquid waste, the combined optimum mass required adsorbent to adsorb Pb(II) ion, the sensitivity of the solid-phase spectrophotometry (sps) method in determining the decrease of Pb (II) metal ion levels in the μg/L level. This research was conducted by experimental method in laboratory. Adsorbents used in this study were charcoal of sawdust sawdust activated using 15% ZnCl2 solution and activated rice husk using 2 N NaOH solution. The adsorption processes of sawdust and rice husk with Pb(II) solution was done by variation of mass combination with a ratio of 1: 0; 0: 1; 1: 1; 1: 2; and 2: 1. Analysis of Pb(II) ion concentration using SPS and characterization of sawdust and rice husk adsorbent ads using FTIR. The results showed that activated charcoal from sawdust of teak wood and rice husks can be used as Pb (II) metal ion adsorbents with adsorption capacity of 0.86 μg/L, charcoal from sawdust of teak wood and rice husk adsorbent with a combination of optimum mass contact of sawdust and rice husk is 2:1 as much as 3 grams can adsorb 42.80 μg/L. Solid-phase spectophotometry is a sensitive method for analysis of concentration decreasing levels of Pb(II) ion, after it was absorbed by sawdust of teak wood and rice husk with high sensitivity and has the limit of detection (LOD) of 0.06 μg/L.

  11. Synthesis and spectroscopic studies of biologically active tetraazamacrocyclic complexes of Mn(II, Co(II, Ni(II, Pd(II and Pt(II

    Directory of Open Access Journals (Sweden)

    Monika Tyagi

    2014-01-01

    Full Text Available Complexes of Mn(II, Co(II, Ni(II, Pd(II and Pt(II were synthesized with the macrocyclic ligand, i.e., 2,3,9,10-tetraketo-1,4,8,11-tetraazacycoletradecane. The ligand was prepared by the [2 + 2] condensation of diethyloxalate and 1,3-diamino propane and characterized by elemental analysis, mass, IR and 1H NMR spectral studies. All the complexes were characterized by elemental analysis, molar conductance, magnetic susceptibility measurements, IR, electronic and electron paramagnetic resonance spectral studies. The molar conductance measurements of Mn(II, Co(II and Ni(II complexes in DMF correspond to non electrolyte nature, whereas Pd(II and Pt(II complexes are 1:2 electrolyte. On the basis of spectral studies an octahedral geometry has been assigned for Mn(II, Co(II and Ni(II complexes, whereas square planar geometry assigned for Pd(II and Pt(II. In vitro the ligand and its metal complexes were evaluated against plant pathogenic fungi (Fusarium odum, Aspergillus niger and Rhizoctonia bataticola and some compounds found to be more active as commercially available fungicide like Chlorothalonil.

  12. A two-dimensional finite element method for analysis of solid body contact problems in fuel rod mechanics

    International Nuclear Information System (INIS)

    Nissen, K.L.

    1988-06-01

    Two computer codes for the analysis of fuel rod behavior have been developed. Fuel rod mechanics is treated by a two-dimensional, axisymmetric finite element method. The program KONTAKT is used for detailed examinations on fuel rod sections, whereas the second program METHOD2D allows instationary calculations of whole fuel rods. The mechanical contact of fuel and cladding during heating of the fuel rod is very important for it's integrity. Both computer codes use a Newton-Raphson iteration for the solution of the nonlinear solid body contact problem. A constitutive equation is applied for the dependency of contact pressure on normal approach of the surfaces which are assumed to be rough. If friction is present on the contacting surfaces, Coulomb's friction law is used. Code validation is done by comparison with known analytical solutions for special problems. Results of the contact algorithm for an elastic ball pressing against a rigid surface are confronted with Hertzian theory. Influences of fuel-pellet geometry as well as influences of discretisation of displacements and stresses of a single fuel pellet are studied. Contact of fuel and cladding is calculated for a fuel rod section with two fuel pellets. The influence of friction forces between fuel and cladding on their axial expansion is demonstrated. By calculation of deformations and temperatures during an instationary fuel rod experiment of the CABRI-series the feasibility of two-dimensional finite element analysis of whole fuel rods is shown. (orig.) [de

  13. Occupational Contact Dermatitis in North American Production Workers Referred for Patch Testing: Retrospective Analysis of Cross-Sectional Data From the North American Contact Dermatitis Group 1998 to 2014.

    Science.gov (United States)

    Warshaw, Erin M; Hagen, Solveig L; DeKoven, Joel G; Zug, Kathryn A; Sasseville, Denis; Belsito, Donald V; Zirwas, Matthew J; Fowler, Joseph F; Taylor, James S; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Maibach, Howard I; Mathias, C G Toby

    Little is known about the epidemiology of contact dermatitis in production workers (PWs). The aims of this study were to estimate the prevalence of contact dermatitis and characterize clinically relevant and occupationally related allergens among North American PWs undergoing patch testing. This was a retrospective cross-sectional analysis of North American Contact Dermatitis Group data from 1998 to 2014. Of 39,332 patch-tested patients, 2732 (7.0%) were PWs. Among PWs, most were men (62.4%) and white (83.9%). A history of childhood eczema was uncommon (11.3%). Prevalent occupations included machine operators (27.3%); fabricators, assemblers, and hand-working occupations (16.8%); and precision metalworking occupations (16.1%). The most frequent sites of dermatitis were the hands (53.8%) and arms (29.4%), which were significantly more commonly affected compared with non-PWs (P contact dermatitis, and irritant contact dermatitis were also significantly more common in PWs (49.9% vs 10.6%, 58.9% vs 53.7%, and 32.7% vs 25.7%, respectively; all Ps contact dermatitis. Involvement of exposed body areas was common. Frequently identified allergens included adhesives/glues, rubber accelerators, metals, and preservatives.

  14. Ethnic Diversity, Inter-group Attitudes and Countervailing Pathways of Positive and Negative Inter-group Contact: An Analysis Across Workplaces and Neighbourhoods.

    Science.gov (United States)

    Laurence, James; Schmid, Katharina; Hewstone, Miles

    2018-01-01

    This study advances the current literature investigating the relationship between contextual out-group exposure, inter-group attitudes and the role of inter-group contact. Firstly, it introduces the concept of contact-valence into this relationship; that is, whether contact is experienced positively or negatively. Secondly, it presents a comparative analysis of how processes of out-group exposure and frequency of (valenced) contact affect prejudice across both neighbourhoods and workplaces. Applying path analysis modelling to a nationally-representative sample of white British individuals in England, we demonstrate, across both contexts, that increasing out-group exposure is associated with higher rates of both positively- and negatively-valenced contact. This results in exposure exhibiting both positive and negative indirect associations with prejudice via more frequent inter-group mixing. These countervailing contact-pathways help explain how out-group exposure is associated with inter-group attitudes. In neighbourhoods, increasing numbers of individuals experiencing positive-contact suppress an otherwise negative effect of neighbourhood diversity (driven partly by increasing numbers of individuals reporting negative contact). Across workplaces the effect differs such that increasing numbers of individuals experiencing negative-contact suppress an otherwise positive effect of workplace diversity (driven largely by increasing numbers of individuals experiencing positive contact).

  15. Fourier Transform Infrared (FTIR) Analysis of Trapa bispinosa: A Novel Adsorbent for the Removal of Cu (II) from Aqueous Solution in Chemically Treated Form

    International Nuclear Information System (INIS)

    Yousaf, M.; Nadeem, R.; Saeed, M.; Zahoor, T.

    2013-01-01

    Current study explored biosorption mechanism and kinetics of Cu (II) onto Trapa bispinosa peels (TBPs) biomass in surfactant (SDS, CTAB, and Triton X-100), organic acid (CA, TA, AA) and in Native (N) form during batch experiment. Equilibrium sorption capacity was determined at various solution parameters like pH, contact time and initial concentration. Increment in sorption capacity was observed with increase in pH until maximum is achieved at pH 5. Optimized time and concentration were 120 minutes and 100 ppm respectively. Best fitted pseudo-second order kinetic model on the data showed that sorption of Cu (II) is rate-controlling. Sorption capacity (mg g-1) for Cu (II) ions increased while % removal decreased. SDS TBPs in comparison to all TBPs show highest sorption tendency as after SDS pretreatment TBPs surface is loaded with the negatively charged groups that provide more attachment sites for Cu (II) ions. Langmuir isotherm give best description of monolayer adsorption over the surface as it fitted better to data. FTIR analysis showed presence of functional groups like amine, carbonyl and hydroxyl groups. Ionization states of these functional groups are changed with pH. (author)

  16. Contact conditions in skin-pass rolling

    DEFF Research Database (Denmark)

    Kijima, Hideo; Bay, Niels

    2007-01-01

    The special contact conditions in skin-pass rolling of steel strip is analysed by studying plane strain upsetting of thin sheet with low reduction applying long narrow tools and dry friction conditions. An extended sticking region is estimated by an elasto-plastic FEM analysis of the plane strain...... upsetting. This sticking region causes a highly inhomogeneous elasto-plastic deformation with large influence of work-hardening and friction. A numerical analysis of skin-pass rolling shows the same contact conditions, i.e. an extended sticking region around the center of the contact zone. The calculated...... size of the sticking region with varying contact length and pressure/reduction is experimentally verified by plane strain upsetting tests measuring the local surface deformation of the work pieces after unloading....

  17. Deodorants are the leading cause of allergic contact dermatitis to fragrance ingredients.

    Science.gov (United States)

    Heisterberg, Maria V; Menné, Torkil; Andersen, Klaus E; Avnstorp, Christian; Kristensen, Berit; Kristensen, Ove; Kaaber, Knud; Laurberg, Grete; Henrik Nielsen, Niels; Sommerlund, Mette; Thormann, Jens; Veien, Niels K; Vissing, Susanne; Johansen, Jeanne D

    2011-05-01

    Fragrances frequently cause contact allergy, and cosmetic products are the main causes of fragrance contact allergy. As the various products have distinctive forms of application and composition of ingredients, some product groups are potentially more likely to play a part in allergic reactions than others. To determine which cosmetic product groups cause fragrance allergy among Danish eczema patients. This was a retrospective study based on data collected by members of the Danish Contact Dermatitis Group. Participants (N = 17,716) were consecutively patch tested with fragrance markers from the European baseline series (2005-2009). Of the participants, 10.1% had fragrance allergy, of which 42.1% was caused by a cosmetic product: deodorants accounted for 25%, and scented lotions 24.4%. A sex difference was apparent, as deodorants were significantly more likely to be listed as the cause of fragrance allergy in men (odds ratio 2.2) than in women. Correlation was observed between deodorants listed as the cause of allergy and allergy detected with fragrance mix II (FM II) and hydroxyisohexyl 3-cyclohexene carboxaldehyde. Deodorants were the leading causes of fragrance allergy, especially among men. Seemingly, deodorants have an 'unhealthy' composition of the fragrance chemicals present in FM II. © 2011 John Wiley & Sons A/S.

  18. A multilevel path analysis of contact frequency between social network members

    Science.gov (United States)

    van den Berg, Pauline; Arentze, Theo; Timmermans, Harry

    2012-04-01

    Recently, there has been an increasing interest in the role of social networks in spatial-choice and travel behavior. It has been acknowledged that social activities and the travel for these activities can emerge from individuals' social networks and that social activities are responsible for an important portion of travel demand. The influence of information and communication technologies (ICT's) is also important in this respect. The purpose of the paper is to examine the effects of characteristics of egos and ego-alter relationships on the frequency of social interaction by different communication modes, using multilevel path analysis. The analyses are based on social network data collected in 2008 in the Eindhoven region in the Netherlands among 116 respondents. The results indicate a complementary relationship between contact frequencies by different modes. The contact frequencies of the different modes, especially face-to-face and telephone, can also be largely explained by the ego's personal characteristics and the type of relationship and the distance between ego and alter.

  19. Leprosy exposure, infection and disease: a 25-year surveillance study of leprosy patient contacts.

    Science.gov (United States)

    Sarno, Euzenir Nunes; Duppre, Nadia Cristina; Sales, Anna Maria; Hacker, Mariana Andréa; Nery, José Augusto; de Matos, Haroldo José

    2012-12-01

    Contact surveillance is a valuable strategy for controlling leprosy. A dynamic cohort study of leprosy contacts was initiated in 1987 at Oswaldo Cruz Foundation. The objective of this work was to review the data on the major risk factors leading up to the infectious stage of the disease, estimate incidence rates of leprosy in the cohort and characterise the risk factors for the disease among the contacts under surveillance. The incidence rate of leprosy among contacts of leprosy patients was estimated at 0.01694 cases per person-year in the first five years of follow-up. The following factors were associated with acquiring the disease: (i) not receiving the BCG vaccine, (ii) a negative Mitsuda reaction and (iii) contact with a patient with a multibacillary clinical form of leprosy. The contacts of index patients who had high bacilloscopic index scores > 1 were at especially high risk of infection. The following factors were associated with infection, which was defined as a seropositive reaction for anti-phenolic glicolipid-1 IgM: (i) young age (< 20 years), (ii) a low measured Mitsuda reaction (< 5 mm) and (iii) contact with an index patient who had a high bacilloscopic index. BCG vaccination and re-vaccination were shown to be protective among household contacts. The main conclusions of this study indicate an urgent need for additional leprosy control strategies in areas with a high incidence of the disease.

  20. Leprosy exposure, infection and disease: a 25-year surveillance study of leprosy patient contacts

    Directory of Open Access Journals (Sweden)

    Euzenir Nunes Sarno

    2012-12-01

    Full Text Available Contact surveillance is a valuable strategy for controlling leprosy. A dynamic cohort study of leprosy contacts was initiated in 1987 at Oswaldo Cruz Foundation. The objective of this work was to review the data on the major risk factors leading up to the infectious stage of the disease, estimate incidence rates of leprosy in the cohort and characterise the risk factors for the disease among the contacts under surveillance. The incidence rate of leprosy among contacts of leprosy patients was estimated at 0.01694 cases per person-year in the first five years of follow-up. The following factors were associated with acquiring the disease: (i not receiving the BCG vaccine, (ii a negative Mitsuda reaction and (iii contact with a patient with a multibacillary clinical form of leprosy. The contacts of index patients who had high bacilloscopic index scores > 1 were at especially high risk of infection. The following factors were associated with infection, which was defined as a seropositive reaction for anti-phenolic glicolipid-1 IgM: (i young age (< 20 years, (ii a low measured Mitsuda reaction (< 5 mm and (iii contact with an index patient who had a high bacilloscopic index. BCG vaccination and re-vaccination were shown to be protective among household contacts. The main conclusions of this study indicate an urgent need for additional leprosy control strategies in areas with a high incidence of the disease.

  1. Removal of Cd(II) and Pb(II) ions, from aqueous solutions, by adsorption onto sawdust of Pinus sylvestris

    International Nuclear Information System (INIS)

    Taty-Costodes, V. Christian; Fauduet, Henri; Porte, Catherine; Delacroix, Alain

    2003-01-01

    Fixation of heavy metal ions (Cd(II) and Pb(II)) onto sawdust of Pinus sylvestris is presented in this paper. Batch experiments were conducted to study the main parameters such as adsorbent concentration, initial adsorbate concentration, contact time, kinetic, pH solution, and stirring velocity on the sorption of Cd(II) and Pb(II) by sawdust of P. sylvestris. Kinetic aspects are studied in order to develop a model which can describe the process of adsorption on sawdust. The equilibrium of a solution between liquid and solid phases is described by Langmuir model. Scanning electronic microscopy (SEM) coupled with energy dispersive X-ray analysis (EDAX) and X-ray photoelectron spectroscopy (XPS) shows that the process is controlled by a porous diffusion with ion-exchange. The capacity of the metal ions to bind onto the biomass was 96% for Cd(II), and 98% for Pb(II). The sorption followed a pseudo-second-order kinetics. The adsorption of these heavy metals ions increased with the pH and reached a maximum at a 5.5 value. From these results, it can be concluded that the sawdust of P. sylvestris could be a good adsorbent for the metal ions coming from aqueous solutions. Moreover, this material could also be used for purification of water before rejection into the natural environment

  2. The Gerda Phase II detector assembly

    Energy Technology Data Exchange (ETDEWEB)

    Bode, Tobias; Schoenert, Stefan [Physik-Department E15, Technische Universitaet Muenchen (Germany); Schwingenheuer, Bernhard [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    Phase II of the Gerda (Germanium Detector Array) experiment will continue the search for the neutrinoless double beta decay (0νββ) of {sup 76}Ge. Prerequisites for Phase II are an increased target mass and a reduced background index of < 10 {sup -3} cts/(keV.kg.yr). Major hardware upgrades to achieve these requirements are scheduled for 2013. They include the deployment of a new radio pure low mass detector assembly. The structural properties of available radio-pure materials and reduction of mass necessitate a change of the electrical contacting used to bias and read-out the detectors. The detector assembly design and the favored contacting solution are presented.

  3. Revised analysis of singly ionized xenon, Xe II

    International Nuclear Information System (INIS)

    Hansen, J.E.; Persson, W.

    1987-01-01

    We present a revised analysis of the spectrum of singly ionized xenon, Xe II. This spectrum has been reanalyzed on the basis of the wavelength material published by Drs J. C. Boyce and C. J. Humphreys. The latter has kindly placed the original wavelength list covering the wavelength range 10220-390 A at our disposal. We report 161 energy levels which have been identified on the basis of classifications of 950 lines. We report first f and g levels in Xe II. Also a number of g-factors have been determined for the first time and we give in total 75 g-factors. We have carried out least-squares fits to the even configurations and report the resulting parameter values and eigenvector compositions. A least-squares fit to the 5p 4 6p configuration is also reported. The levels have been named in jK and for many levels also in LS coupling. The former is the better coupling scheme for Xe II. We present an analysis of the 5s photoelectron satellite spectrum of Xe based on our calculated eigenvector compositions and calculations of transition probabilities for ground state transitions as well as lifetimes for the 6p levels. The latter are compared to recent experimental measurements. A list of wavelengths for observed laser transitions showing the present classifications and a discussion of the determination of the ionization potential of Xe II concludes the paper. (orig.)

  4. An Electropalatographic Investigation of Linguopalatal Contact in Participants with Acquired Apraxia of Speech: A Quantitative and Qualitative Analysis

    Science.gov (United States)

    Bartle-Meyer, Carly J.; Murdoch, Bruce E.; Goozee, Justine V.

    2009-01-01

    The current study aimed to provide a comprehensive analysis of linguopalatal contact patterns in participants with acquired apraxia of speech (AOS). Tongue-to-palate contacts were recorded for three participants with AOS during consonant singletons and consonant clusters using the Reading Electropalatograph (EPG3) system. Amount and pattern of…

  5. Contact Patterns in a High School: A Comparison between Data Collected Using Wearable Sensors, Contact Diaries and Friendship Surveys.

    Directory of Open Access Journals (Sweden)

    Rossana Mastrandrea

    Full Text Available Given their importance in shaping social networks and determining how information or transmissible diseases propagate in a population, interactions between individuals are the subject of many data collection efforts. To this aim, different methods are commonly used, ranging from diaries and surveys to decentralised infrastructures based on wearable sensors. These methods have each advantages and limitations but are rarely compared in a given setting. Moreover, as surveys targeting friendship relations might suffer less from memory biases than contact diaries, it is interesting to explore how actual contact patterns occurring in day-to-day life compare with friendship relations and with online social links. Here we make progresses in these directions by leveraging data collected in a French high school and concerning (i face-to-face contacts measured by two concurrent methods, namely wearable sensors and contact diaries, (ii self-reported friendship surveys, and (iii online social links. We compare the resulting data sets and find that most short contacts are not reported in diaries while long contacts have a large reporting probability, and that the durations of contacts tend to be overestimated in the diaries. Moreover, measured contacts corresponding to reported friendship can have durations of any length but all long contacts do correspond to a reported friendship. On the contrary, online links that are not also reported in the friendship survey correspond to short face-to-face contacts, highlighting the difference of nature between reported friendships and online links. Diaries and surveys suffer moreover from a low sampling rate, as many students did not fill them, showing that the sensor-based platform had a higher acceptability. We also show that, despite the biases of diaries and surveys, the overall structure of the contact network, as quantified by the mixing patterns between classes, is correctly captured by both networks of self

  6. Contact Patterns in a High School: A Comparison between Data Collected Using Wearable Sensors, Contact Diaries and Friendship Surveys.

    Science.gov (United States)

    Mastrandrea, Rossana; Fournet, Julie; Barrat, Alain

    2015-01-01

    Given their importance in shaping social networks and determining how information or transmissible diseases propagate in a population, interactions between individuals are the subject of many data collection efforts. To this aim, different methods are commonly used, ranging from diaries and surveys to decentralised infrastructures based on wearable sensors. These methods have each advantages and limitations but are rarely compared in a given setting. Moreover, as surveys targeting friendship relations might suffer less from memory biases than contact diaries, it is interesting to explore how actual contact patterns occurring in day-to-day life compare with friendship relations and with online social links. Here we make progresses in these directions by leveraging data collected in a French high school and concerning (i) face-to-face contacts measured by two concurrent methods, namely wearable sensors and contact diaries, (ii) self-reported friendship surveys, and (iii) online social links. We compare the resulting data sets and find that most short contacts are not reported in diaries while long contacts have a large reporting probability, and that the durations of contacts tend to be overestimated in the diaries. Moreover, measured contacts corresponding to reported friendship can have durations of any length but all long contacts do correspond to a reported friendship. On the contrary, online links that are not also reported in the friendship survey correspond to short face-to-face contacts, highlighting the difference of nature between reported friendships and online links. Diaries and surveys suffer moreover from a low sampling rate, as many students did not fill them, showing that the sensor-based platform had a higher acceptability. We also show that, despite the biases of diaries and surveys, the overall structure of the contact network, as quantified by the mixing patterns between classes, is correctly captured by both networks of self-reported contacts and

  7. Vibration Analysis of a Tire in Ground Contact under Varied Conditions

    OpenAIRE

    Karakus Murat; Cavus Aydin; Colakoglu Mehmet

    2017-01-01

    The effect of three different factors, which are inflation pressure, vertical load and coefficient of friction on the natural frequencies of a tire (175/70 R13) has been studied. A three dimensional tire model is constructed, using four different material properties and parts in the tire. Mechanical properties of the composite parts are evaluated. After investigating the free vibration, contact analysis is carried out. A concrete block and the tire are modelled together, using three different...

  8. Synthesis and physicochemical analysis of Sm (II, III) acetylacetone chelate complexes

    International Nuclear Information System (INIS)

    Kostyuk, N.N.; Dik, T.A.; Trebnikov, A.G.

    2004-01-01

    Sm (II, III) acetylacetone chelate complexes were synthesized by electrochemical method. It was shown that anode dissolution of the metal samarium over acetylacetone leads to formation of the Sm (II, III) chelate complexes: xSm(acac)2 · ySm(acac)3 · zH(acac). Factors x, y and z depend on quantity of the electricity, which flew through the electrolysis cell. The compositions of the obtained substances were confirmed by the physicochemical analysis (ultimate analysis, IR-, mass spectroscopy and thermal analysis (thermogravimetric, isothermal warming-up and differential scanning colorimetry). (Authors)

  9. Allergic contact dermatitis to fragrances: part 2.

    Science.gov (United States)

    Arribas, M P; Soro, P; Silvestre, J F

    2013-01-01

    Allergic contact dermatitis due to fragrances usually manifests as subacute or chronic dermatitis because fragrances are found in a wide range of products to which patients are repeatedly exposed. The typical patient is a middle-aged woman with dermatitis on her hands and face, although other sites may be affected depending on the allergen and the product in which it is found. The standard patch test series of the Spanish Contact Dermatitis and Skin Allergy Research Group (GEIDAC) contains 4 fragrance markers: balsam of Peru, fragrance mix i, fragrance mix ii, and lyral. Testing with a specific fragrance series is recommended in patients with a positive result to any of these 4 markers. The use of a specific fragrance series and new legislation obliging manufacturers to specify the fragrances used in their products, will help to improve the management of allergic contact dermatitis due to fragrances. Copyright © 2012 Elsevier España, S.L. and AEDV. All rights reserved.

  10. Secondary Contact and Admixture between Independently Invading Populations of the Western Corn Rootworm, Diabrotica virgifera virgifera in Europe

    Science.gov (United States)

    Bermond, Gérald; Ciosi, Marc; Lombaert, Eric; Blin, Aurélie; Boriani, Marco; Furlan, Lorenzo; Toepfer, Stefan; Guillemaud, Thomas

    2012-01-01

    The western corn rootworm, Diabrotica virgifera virgifera (Coleoptera: Chrysomelidae), is one of the most destructive pests of corn in North America and is currently invading Europe. The two major invasive outbreaks of rootworm in Europe have occurred, in North-West Italy and in Central and South-Eastern Europe. These two outbreaks originated from independent introductions from North America. Secondary contact probably occurred in North Italy between these two outbreaks, in 2008. We used 13 microsatellite markers to conduct a population genetics study, to demonstrate that this geographic contact resulted in a zone of admixture in the Italian region of Veneto. We show that i) genetic variation is greater in the contact zone than in the parental outbreaks; ii) several signs of admixture were detected in some Venetian samples, in a Bayesian analysis of the population structure and in an approximate Bayesian computation analysis of historical scenarios and, finally, iii) allelic frequency clines were observed at microsatellite loci. The contact between the invasive outbreaks in North-West Italy and Central and South-Eastern Europe resulted in a zone of admixture, with particular characteristics. The evolutionary implications of the existence of a zone of admixture in Northern Italy and their possible impact on the invasion success of the western corn rootworm are discussed. PMID:23189184

  11. Numerical analysis of rolling contact fatigue crack initiation and fatigue life prediction of the railway crossing

    OpenAIRE

    Xin, L.; Markine, V.L.; Shevtsov, I.

    2015-01-01

    The procedure for analysing rolling contact fatigue crack initiation and fatigue life prediction of the railway turnout crossing is developed. A three-dimensional finite element (FE) model is used to obtain stress and strain results, considering the dynamic effects of wheel-crossing rolling contact. Material model accounting for elastic- plastic isotropic and kinematic hardening effects is adopted. The results from FE analysis are combined with J-S fatigue model that is based on critical plan...

  12. Mechanisms of current flow in metal-semiconductor ohmic contacts

    International Nuclear Information System (INIS)

    Blank, T. V.; Gol'dberg, Yu. A.

    2007-01-01

    Published data on the properties of metal-semiconductor ohmic contacts and mechanisms of current flow in these contacts (thermionic emission, field emission, thermal-field emission, and also current flow through metal shunts) are reviewed. Theoretical dependences of the resistance of an ohmic contact on temperature and the charge-carrier concentration in a semiconductor were compared with experimental data on ohmic contacts to II-VI semiconductors (ZnSe, ZnO), III-V semiconductors (GaN, AlN, InN, GaAs, GaP, InP), Group IV semiconductors (SiC, diamond), and alloys of these semiconductors. In ohmic contacts based on lightly doped semiconductors, the main mechanism of current flow is thermionic emission with the metal-semiconductor potential barrier height equal to 0.1-0.2 eV. In ohmic contacts based on heavily doped semiconductors, the current flow is effected owing to the field emission, while the metal-semiconductor potential barrier height is equal to 0.3-0.5 eV. In alloyed In contacts to GaP and GaN, a mechanism of current flow that is not characteristic of Schottky diodes (current flow through metal shunts formed by deposition of metal atoms onto dislocations or other imperfections in semiconductors) is observed

  13. Determination of the mechanical thermostat electrical contacts switching quality with sound and vibration analysis

    Energy Technology Data Exchange (ETDEWEB)

    Rejc, Jure; Munih, Marko [University of Ljubljana, Ljubljana (Slovenia)

    2017-05-15

    A mechanical thermostat is a device that switches heating or cooling appliances on or off based on temperature. For this kind of use, electronic or mechanical switching concepts are applied. During the production of electrical contacts, several irregularities can occur leading to improper switching events of the thermostat electrical contacts. This paper presents a non-obstructive method based on the fact that when the switching event occurs it can be heard and felt by human senses. We performed several laboratory tests with two different methods. The first method includes thermostat switch sound signal analysis during the switching event. The second method is based on sampling of the accelerometer signal during the switching event. The results show that the sound analysis approach has great potential. The approach enables an accurate determination of the switching event even if the sampled signal carries also the switching event of the neighbour thermostat.

  14. 77 FR 64396 - Order of Succession for HUD Region II

    Science.gov (United States)

    2012-10-19

    ... Region II AGENCY: Office of Field Policy and Management, HUD. ACTION: Notice of Order of Succession... Field Offices (Region II). This Order of Succession supersedes all previous Orders of Succession for Region II. DATES: Effective Date: October 9, 2012. FOR FURTHER INFORMATION CONTACT: Lawrence D. Reynolds...

  15. Towards using tire-road contact stresses in pavement design and analysis

    CSIR Research Space (South Africa)

    De Beer, Morris

    2011-09-01

    Full Text Available stream_source_info De Beer_2012.pdf.txt stream_content_type text/plain stream_size 79981 Content-Encoding ISO-8859-1 stream_name De Beer_2012.pdf.txt Content-Type text/plain; charset=ISO-8859-1 Towards Using Tire...-Road Contact Stresses in Pavement Design and Analysis M. De Beer*, J. W. Maina, Y. van Rensburg, J. M. Greben mbeer@csir.co.za CSIR Built Environment P O Box 395 Pretoria 0001 South Africa Presented at the September 2011 Meeting...

  16. Fragrance mix II in the baseline series contributes significantly to detection of fragrance allergy

    DEFF Research Database (Denmark)

    Heisterberg, Maria V; Andersen, Klaus E; Avnstorp, Christian

    2010-01-01

    Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens.......Fragrance mix II (FM II) is a relatively new screening marker for fragrance contact allergy. It was introduced in the patch test baseline series in Denmark in 2005 and contains six different fragrance chemicals commonly present in cosmetic products and which are known allergens....

  17. Indentation analysis of nano-particle using nano-contact mechanics models during nano-manipulation based on atomic force microscopy

    International Nuclear Information System (INIS)

    Daeinabi, Khadijeh; Korayem, Moharam Habibnejad

    2011-01-01

    Atomic force microscopy is applied to measure intermolecular forces and mechanical properties of materials, nano-particle manipulation, surface scanning and imaging with atomic accuracy in the nano-world. During nano-manipulation process, contact forces cause indentation in contact area between nano-particle and tip/substrate which is considerable at nano-scale and affects the nano-manipulation process. Several nano-contact mechanics models such as Hertz, Derjaguin–Muller–Toporov (DMT), Johnson–Kendall–Roberts–Sperling (JKRS), Burnham–Colton–Pollock (BCP), Maugis–Dugdale (MD), Carpick–Ogletree–Salmeron (COS), Pietrement–Troyon (PT), and Sun et al. have been applied as the continuum mechanics approaches at nano-scale. In this article, indentation depth and contact radius between tip and substrate with nano-particle for both spherical and conical tip shape during nano-manipulation process are analyzed and compared by applying theoretical, semiempirical, and empirical nano-contact mechanics models. The effects of adhesion force, as the main contrast point in different nano-contact mechanics models, on nano-manipulation analysis is investigated for different contact radius, and the critical point is discussed for mentioned models.

  18. Thermodynamic analysis of effects of contact angle on interfacial interactions and its implications for membrane fouling control.

    Science.gov (United States)

    Chen, Jianrong; Shen, Liguo; Zhang, Meijia; Hong, Huachang; He, Yiming; Liao, Bao-Qiang; Lin, Hongjun

    2016-02-01

    Concept of hydrophobicity always fails to accurately assess the interfacial interaction and membrane fouling, which calls for reliable parameters for this purpose. In this study, effects of contact angle on interfacial interactions related to membrane fouling were investigated based on thermodynamic analysis. It was found that, total interaction energy between sludge foulants and membrane monotonically decreases and increases with water and glycerol contact angle, respectively, indicating that these two parameters can be reliable indicators predicting total interaction energy and membrane fouling. Membrane roughness decreases interaction strength for over 20 times, and effects of membrane roughness on membrane fouling should consider water and glycerol contact angle on membrane. It was revealed existence of a critical water and glycerol contact angle for a given membrane bioreactor. Meanwhile, diiodomethane contact angle has minor effect on the total interaction, and cannot be regarded as an effective indicator assessing interfacial interactions and membrane fouling. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. [Tonometry with a new non-contact tonometer].

    Science.gov (United States)

    Langmann, G; Schuhmann, G; Langmann, A; Zenz, H

    1990-11-01

    We conducted comparative measurements with 100 healthy probands and patients suffering of glaucoma with both a Goldmann Applanation Tonometer (GAT) and the new Keeler Non Contact Tonometer (NCT). A noticeable conformity of mean values in the group I with values under 23 mm Hg and in group II with values greater or equal 23 mm Hg was obvious. The results of three NCT measurement values were compared with those of four measurements. The Keeler NCT nearly fulfills the needed criteria for the first group with pressure under 23 mm Hg except for a high standard deviation. In group II (pressure greater or equal 23 mm Hg) the demanded nominal values are exceeded.

  20. A model of mechanical contacts in hearing aids for uncertainty analysis

    DEFF Research Database (Denmark)

    Creixell Mediante, Ester; Brunskog, Jonas; Jensen, Jakob Søndergaard

    2015-01-01

    Modelling the contact between assembled parts is a key point in the design of complex structures. Uncertainties at the joint parameters arise as a result of randomness in physical properties such as contact surface, load distribution or geometric details. This is a challenge of concern in the hea......Modelling the contact between assembled parts is a key point in the design of complex structures. Uncertainties at the joint parameters arise as a result of randomness in physical properties such as contact surface, load distribution or geometric details. This is a challenge of concern...... in the hearing aid field, where the small lightweight structures present vibration modes at frequencies within the hearing range. To approach this issue, a model of contacts based on lumped elements is suggested. The joint parameters are the stiffness of a series of spring elements placed along the contact...

  1. A Numerical Procedure for Analysis of W/R Contact Using Explicit Finite Element Methods

    NARCIS (Netherlands)

    Ma, Y.; Markine, V.L.

    2015-01-01

    Since no effective experimental approaches have been proposed to assess wheel and rail (W/R) contact performance till now, numerical computational analysis is known as an alternative to approximately simulate the W/R interaction. In this paper, one numerical procedure is proposed on the basis of

  2. Theoretical investigations of two adamantane derivatives: A combined X-ray, DFT, QTAIM analysis and molecular docking

    Science.gov (United States)

    Al-Wahaibi, Lamya H.; Sujay, Subramaniam; Muthu, Gangadharan Ganesh; El-Emam, Ali A.; Venkataramanan, Natarajan S.; Al-Omary, Fatmah A. M.; Ghabbour, Hazem A.; Percino, Judith; Thamotharan, Subbiah

    2018-05-01

    A detailed structural analysis of two adamantane derivatives namely, ethyl 2-[(Z)-1-(adamantan-1-yl)-3-(phenyl)isothioureido]acetate I and ethyl 2-[(Z)-1-(adamantan-1-yl)-3-(4-fluorophenyl)isothioureido]acetate II is carried out to understand the effect of fluorine substitution. The introduction of fluorine atom alters the crystal packing and is completely different from its parent compound. The fluorine substitution drastically reduced the intermolecular H⋯H contacts and this reduction is compensated by intermolecular F⋯H and F⋯F contacts. The relative contributions of various intermolecular contacts present in these structures were quantified using Hirshfeld surface analysis. Energetically significant molecular pairs were identified from the crystal structures of these compounds using PIXEL method. The structures of I and II are optimized in gas and solvent phases using the B3LYP-D3/6-311++G(d,p) level of theory. The quantum theory of atoms-in-molecules (QTAIM) analysis was carried out to estimate the strengths of various intermolecular contacts present in these molecular dimers. The results suggest that the Hsbnd H bonding take part in the stabilization of crystal structures. The experimental and theoretical UV-Vis results show the variations in HOMO and LUMO energy levels. In silico docking analysis indicates that both compounds I and II may exhibit inhibitory activity against 11-β-hydroxysteroid dehydrogenase 1 (11-β-HSD1).

  3. FreeContact: fast and free software for protein contact prediction from residue co-evolution.

    Science.gov (United States)

    Kaján, László; Hopf, Thomas A; Kalaš, Matúš; Marks, Debora S; Rost, Burkhard

    2014-03-26

    20 years of improved technology and growing sequences now renders residue-residue contact constraints in large protein families through correlated mutations accurate enough to drive de novo predictions of protein three-dimensional structure. The method EVfold broke new ground using mean-field Direct Coupling Analysis (EVfold-mfDCA); the method PSICOV applied a related concept by estimating a sparse inverse covariance matrix. Both methods (EVfold-mfDCA and PSICOV) are publicly available, but both require too much CPU time for interactive applications. On top, EVfold-mfDCA depends on proprietary software. Here, we present FreeContact, a fast, open source implementation of EVfold-mfDCA and PSICOV. On a test set of 140 proteins, FreeContact was almost eight times faster than PSICOV without decreasing prediction performance. The EVfold-mfDCA implementation of FreeContact was over 220 times faster than PSICOV with negligible performance decrease. EVfold-mfDCA was unavailable for testing due to its dependency on proprietary software. FreeContact is implemented as the free C++ library "libfreecontact", complete with command line tool "freecontact", as well as Perl and Python modules. All components are available as Debian packages. FreeContact supports the BioXSD format for interoperability. FreeContact provides the opportunity to compute reliable contact predictions in any environment (desktop or cloud).

  4. Discrete element analysis is a valid method for computing joint contact stress in the hip before and after acetabular fracture.

    Science.gov (United States)

    Townsend, Kevin C; Thomas-Aitken, Holly D; Rudert, M James; Kern, Andrew M; Willey, Michael C; Anderson, Donald D; Goetz, Jessica E

    2018-01-23

    Evaluation of abnormalities in joint contact stress that develop after inaccurate reduction of an acetabular fracture may provide a potential means for predicting the risk of developing post-traumatic osteoarthritis. Discrete element analysis (DEA) is a computational technique for calculating intra-articular contact stress distributions in a fraction of the time required to obtain the same information using the more commonly employed finite element analysis technique. The goal of this work was to validate the accuracy of DEA-computed contact stress against physical measurements of contact stress made in cadaveric hips using Tekscan sensors. Four static loading tests in a variety of poses from heel-strike to toe-off were performed in two different cadaveric hip specimens with the acetabulum intact and again with an intentionally malreduced posterior wall acetabular fracture. DEA-computed contact stress was compared on a point-by-point basis to stress measured from the physical experiments. There was good agreement between computed and measured contact stress over the entire contact area (correlation coefficients ranged from 0.88 to 0.99). DEA-computed peak contact stress was within an average of 0.5 MPa (range 0.2-0.8 MPa) of the Tekscan peak stress for intact hips, and within an average of 0.6 MPa (range 0-1.6 MPa) for fractured cases. DEA-computed contact areas were within an average of 33% of the Tekscan-measured areas (range: 1.4-60%). These results indicate that the DEA methodology is a valid method for accurately estimating contact stress in both intact and fractured hips. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Vibration Analysis of a Tire in Ground Contact under Varied Conditions

    Directory of Open Access Journals (Sweden)

    Karakus Murat

    2017-03-01

    Full Text Available The effect of three different factors, which are inflation pressure, vertical load and coefficient of friction on the natural frequencies of a tire (175/70 R13 has been studied. A three dimensional tire model is constructed, using four different material properties and parts in the tire. Mechanical properties of the composite parts are evaluated. After investigating the free vibration, contact analysis is carried out. A concrete block and the tire are modelled together, using three different coefficients of friction. Experiments are run under certain conditions to check the accuracy of the numerical model. The natural frequencies are measured to describe free vibration and vibration of the tire contacted by ground, using a damping monitoring method. It is seen, that experimental and numerical results are in good agreement. On the other hand, investigating the impact of three different factors together is quite difficult on the natural frequencies. When some of these factors are assumed to be constant and the variables are taken one by one, it is easier to assess the effects.

  6. HiC-spector: a matrix library for spectral and reproducibility analysis of Hi-C contact maps.

    Science.gov (United States)

    Yan, Koon-Kiu; Yardimci, Galip Gürkan; Yan, Chengfei; Noble, William S; Gerstein, Mark

    2017-07-15

    Genome-wide proximity ligation based assays like Hi-C have opened a window to the 3D organization of the genome. In so doing, they present data structures that are different from conventional 1D signal tracks. To exploit the 2D nature of Hi-C contact maps, matrix techniques like spectral analysis are particularly useful. Here, we present HiC-spector, a collection of matrix-related functions for analyzing Hi-C contact maps. In particular, we introduce a novel reproducibility metric for quantifying the similarity between contact maps based on spectral decomposition. The metric successfully separates contact maps mapped from Hi-C data coming from biological replicates, pseudo-replicates and different cell types. Source code in Julia and Python, and detailed documentation is available at https://github.com/gersteinlab/HiC-spector . koonkiu.yan@gmail.com or mark@gersteinlab.org. Supplementary data are available at Bioinformatics online. © The Author(s) 2017. Published by Oxford University Press.

  7. Deep functional analysis of synII, a 770 kb synthetic yeast chromosome

    Science.gov (United States)

    Gao, Feng; Gong, Jianhui; Abramczyk, Dariusz; Walker, Roy; Zhao, Hongcui; Chen, Shihong; Liu, Wei; Luo, Yisha; Müller, Carolin A.; Paul-Dubois-Taine, Adrien; Alver, Bonnie; Stracquadanio, Giovanni; Mitchell, Leslie A.; Luo, Zhouqing; Fan, Yanqun; Zhou, Baojin; Wen, Bo; Tan, Fengji; Wang, Yujia; Zi, Jin; Xie, Zexiong; Li, Bingzhi; Yang, Kun; Richardson, Sarah M.; Jiang, Hui; French, Christopher E.; Nieduszynski, Conrad A.; Koszul, Romain; Marston, Adele L.; Yuan, Yingjin; Wang, Jian; Bader, Joel S.; Dai, Junbiao; Boeke, Jef D.; Xu, Xun; Cai, Yizhi; Yang, Huanming

    2017-01-01

    Herein we report the successful design, construction and characterization of a 770 kb synthetic yeast chromosome II (synII). Our study incorporates characterization at multiple levels, including phenomics, transcriptomics, proteomics, chromosome segregation and replication analysis to provide a thorough and comprehensive analysis of a synthetic chromosome. Our “Trans-Omics” analyses reveal a modest but potentially significant pervasive up-regulation of translational machinery observed in synII is mainly caused by the deletion of 13 tRNAs. By both complementation assays and SCRaMbLE, we targeted and debuged the origin of a growth defect at 37°C in glycerol medium, which is related to misregulation of the HOG response. Despite the subtle differences, the synII strain shows highly consistent biological processes comparable to the native strain. PMID:28280153

  8. Economics of United States tuberculosis airline contact investigation policies: a return on investment analysis.

    Science.gov (United States)

    Coleman, Margaret S; Marienau, Karen J; Marano, Nina; Marks, Suzanne M; Cetron, Martin S

    2014-01-01

    In 2011, the Centers for Disease Control and Prevention modified its 2008 protocol for flight-related tuberculosis contact investigation initiation. The 2011 Modified protocol was implemented and replaced the 2008 CDC protocol based on comparative epidemiologic and economic analyses; this publication reports the economic analysis results. A return on investment model compared relative changes in tuberculosis disease treatment costs resulting from expenditures on tuberculosis contact investigations and latent tuberculosis infection treatment for the 2008 CDC and Modified protocols. At moderate/high rates of latent tuberculosis infection and tuberculosis disease, positive returns on investment indicated each $1.00 spent on tuberculosis contact investigations and latent tuberculosis treatment resulted in more than $1.00 of savings from reduced tuberculosis disease treatment costs. Low rates of latent tuberculosis infection and tuberculosis disease resulted in negative returns on investment, indicating economic losses from tuberculosis disease treatment costs. There were smaller economic losses at low latent tuberculosis infection and tuberculosis disease rates with the Modified protocol in comparison to the 2008 CDC protocol, while both identified comparable numbers of persons at risk for tuberculosis. The Modified protocol for conducting flight-related tuberculosis contact investigations represents a better use of resources and protects public health. Published by Elsevier Ltd.

  9. Deep functional analysis of synII, a 770 kb synthetic yeast chromosome

    OpenAIRE

    Shen, Yue; Wang, Yun; Chen, Tai; Gao, Feng; Gong, Jianhui; Abramczyk, Dariusz; Walker, Roy; Zhao, Hongcui; Chen, Shihong; Liu, Wei; Luo, Yisha; Müller, Carolin A.; Paul-Dubois-Taine, Adrien; Alver, Bonnie; Stracquadanio, Giovanni

    2017-01-01

    Herein we report the successful design, construction and characterization of a 770 kb synthetic yeast chromosome II (synII). Our study incorporates characterization at multiple levels, including phenomics, transcriptomics, proteomics, chromosome segregation and replication analysis to provide a thorough and comprehensive analysis of a synthetic chromosome. Our “Trans-Omics” analyses reveal a modest but potentially significant pervasive up-regulation of translational machinery observed in synI...

  10. A review of micro-contact physics, materials, and failure mechanisms in direct-contact RF MEMS switches

    International Nuclear Information System (INIS)

    Basu, A; Adams, G G; McGruer, N E

    2016-01-01

    Direct contact, ohmic MEMS switches for RF applications have several advantages over other conventional switching devices. Advantages include lower insertion loss, higher isolation, and better switching figure-of-merit (cut-off frequency). The most important aspect of a direct-contact RF MEMS switch is the metal microcontact which can dictate the lifetime and reliability of the switch. Therefore, an understanding of contact reliability is essential for developing robust MEMS switches. This paper discusses and reviews the most important work done over the past couple of decades toward understanding ohmic micro-contacts. We initially discuss the contact mechanics and multi-physics models for studying Hertzian and multi-asperity contacts. We follow this with a discussion on models and experiments for studying adhesion. We then discuss experimental setups and the development of contact test stations by various groups for accelerated testing of microcontacts, as well as for analysis of contact reliability issues. Subsequently, we analyze a number of material transfer mechanisms in microcontacts under hot and cold switching conditions. We finally review the material properties that can help determine the selection of contact materials. A trade-off between contact resistance and high reliability is almost always necessary during selection of contact material; this paper discusses how the choice of materials can help address such trade-offs. (paper)

  11. Identification of contact and respiratory sensitizers according to IL-4 receptor α expression and IL-2 production

    Energy Technology Data Exchange (ETDEWEB)

    Goutet, Michèle, E-mail: michele.goutet@inrs.fr; Pépin, Elsa; Langonné, Isabelle; Huguet, Nelly; Ban, Masarin

    2012-04-15

    Identification of allergenic chemicals is an important occupational safety issue. While several methods exist to identify contact sensitizers, there is currently no validated model to predict the potential of chemicals to act as respiratory sensitizers. Previously, we reported that cytometry analysis of the local immune responses induced in mice dermally exposed to the respiratory sensitizer trimellitic anhydride (TMA 10%) and contact sensitizer dinitrochlorobenzene (DNCB 1%) could identify divergent expression of several immune parameters. The present study confirms, first, that IgE-positive B cells, MHC class II molecules, interleukin (IL)-2, IL-4 and IL-4Rα can differentiate the allergic reactions caused by high doses of strong respiratory (TMA, phthalic anhydride and toluene diisocyanate) and contact sensitizers (DNCB, dinitrofluorobenzene and oxazolone). The second part of the study was designed to test the robustness of these markers when classing the weakly immunogenic chemicals most often encountered. Six respiratory allergens, including TMA (2.5%), five contact allergens, including DNCB (0.25%), and two irritants were compared at doses of equivalent immunogenicity. The results indicated that IL-4Rα and IL-2 can be reliably used to discriminate sensitizers. Respiratory sensitizers induced markedly higher IL-4Rα levels than contact allergens, while irritants had no effect on this parameter. Inversely, contact allergens tended to induce higher percentages of IL-2{sup +}CD8{sup +} cells than respiratory allergens. In contrast, the markers MHC-II, IgE and IL-4 were not able to classify chemicals with low immunogenic potential. In conclusion, IL-4Rα and IL-2 have the potential to be used in classifying a variety of chemical allergens. -- Highlights: ► Identification of chemical allergens is an important occupational safety issue. ► There is currently no model to predict the potential of chemicals to induce asthma. ► We analyze immune responses induced

  12. Identification of contact and respiratory sensitizers according to IL-4 receptor α expression and IL-2 production

    International Nuclear Information System (INIS)

    Goutet, Michèle; Pépin, Elsa; Langonné, Isabelle; Huguet, Nelly; Ban, Masarin

    2012-01-01

    Identification of allergenic chemicals is an important occupational safety issue. While several methods exist to identify contact sensitizers, there is currently no validated model to predict the potential of chemicals to act as respiratory sensitizers. Previously, we reported that cytometry analysis of the local immune responses induced in mice dermally exposed to the respiratory sensitizer trimellitic anhydride (TMA 10%) and contact sensitizer dinitrochlorobenzene (DNCB 1%) could identify divergent expression of several immune parameters. The present study confirms, first, that IgE-positive B cells, MHC class II molecules, interleukin (IL)-2, IL-4 and IL-4Rα can differentiate the allergic reactions caused by high doses of strong respiratory (TMA, phthalic anhydride and toluene diisocyanate) and contact sensitizers (DNCB, dinitrofluorobenzene and oxazolone). The second part of the study was designed to test the robustness of these markers when classing the weakly immunogenic chemicals most often encountered. Six respiratory allergens, including TMA (2.5%), five contact allergens, including DNCB (0.25%), and two irritants were compared at doses of equivalent immunogenicity. The results indicated that IL-4Rα and IL-2 can be reliably used to discriminate sensitizers. Respiratory sensitizers induced markedly higher IL-4Rα levels than contact allergens, while irritants had no effect on this parameter. Inversely, contact allergens tended to induce higher percentages of IL-2 + CD8 + cells than respiratory allergens. In contrast, the markers MHC-II, IgE and IL-4 were not able to classify chemicals with low immunogenic potential. In conclusion, IL-4Rα and IL-2 have the potential to be used in classifying a variety of chemical allergens. -- Highlights: ► Identification of chemical allergens is an important occupational safety issue. ► There is currently no model to predict the potential of chemicals to induce asthma. ► We analyze immune responses induced in mice

  13. Structural, Functional, and Metabolic Brain Markers Differentiate Collision versus Contact and Non-Contact Athletes.

    Science.gov (United States)

    Churchill, Nathan W; Hutchison, Michael G; Di Battista, Alex P; Graham, Simon J; Schweizer, Tom A

    2017-01-01

    There is growing concern about how participation in contact sports affects the brain. Retrospective evidence suggests that contact sports are associated with long-term negative health outcomes. However, much of the research to date has focused on former athletes with significant health problems. Less is known about the health of current athletes in contact and collision sports who have not reported significant medical issues. In this cross-sectional study, advanced magnetic resonance imaging (MRI) was used to evaluate multiple aspects of brain physiology in three groups of athletes participating in non-contact sports ( N  = 20), contact sports ( N  = 22), and collision sports ( N  = 23). Diffusion tensor imaging was used to assess white matter microstructure based on measures of fractional anisotropy (FA) and mean diffusivity (MD); resting-state functional MRI was used to evaluate global functional connectivity; single-voxel spectroscopy was used to compare ratios of neural metabolites, including N -acetyl aspartate (NAA), creatine (Cr), choline, and myo-inositol. Multivariate analysis revealed structural, functional, and metabolic measures that reliably differentiated between sport groups. The collision group had significantly elevated FA and reduced MD in white matter, compared to both contact and non-contact groups. In contrast, the collision group showed significant reductions in functional connectivity and the NAA/Cr metabolite ratio, relative to only the non-contact group, while the contact group overlapped with both non-contact and collision groups. For brain regions associated with contact sport participation, athletes with a history of concussion also showed greater alterations in FA and functional connectivity, indicating a potential cumulative effect of both contact exposure and concussion history on brain physiology. These findings indicate persistent differences in brain physiology for athletes participating in contact and collision sports

  14. Analysis of a Unilateral Contact Problem with Normal Compliance

    Directory of Open Access Journals (Sweden)

    Touzaline Arezki

    2014-06-01

    Full Text Available The paper deals with the study of a quasistatic unilateral contact problem between a nonlinear elastic body and a foundation. The contact is modelled with a normal compliance condition associated to unilateral constraint and the Coulomb's friction law. The adhesion between contact surfaces is taken into account and is modelled with a surface variable, the bonding field, whose evolution is described by a first-order differential equation. We establish a variational formulation of the mechanical problem and prove an existence and uniqueness result in the case where the coefficient of friction is bounded by a certain constant. The technique of the proof is based on arguments of time-dependent variational inequalities, differential equations and fixed-point theorem.

  15. Cloning and sequence analysis of putative type II fatty acid synthase ...

    Indian Academy of Sciences (India)

    Prakash

    Cloning and sequence analysis of putative type II fatty acid synthase genes from Arachis hypogaea L. ... acyl carrier protein (ACP), malonyl-CoA:ACP transacylase, β-ketoacyl-ACP .... Helix II plays a dominant role in the interaction ... main distinguishing features of plant ACPs in plastids and ..... synthase component; J. Biol.

  16. A birth cohort analysis of dental contact among elderly Americans.

    Science.gov (United States)

    Wolinsky, F D; Arnold, C L

    1989-01-01

    We applied standard cohort and multiple regression techniques to data on the dental utilization rates of 129,191 elderly individuals taken from the 1972, 1973, 1976, 1977, 1980, and 1981 Health Interview Surveys. The results indicate that the marked variation in dental contact rates is a reflection of cohort succession, and not a function of aging per se. Older cohorts having lower dental contact rates are being replaced by younger cohorts having higher dental contact rates. The dental contact rates of the individual birth cohorts themselves are quite stable over time. The results also indicate that economic barriers (especially liquid assets) have become more important than ever before, especially for the oldest-old. These findings have important implications for public policy about the oral health and health care of elderly Americans. PMID:2783297

  17. 'Now she has become my daughter': parents' early experiences of skin-to-skin contact with extremely preterm infants.

    Science.gov (United States)

    Maastrup, Ragnhild; Weis, Janne; Engsig, Anne B; Johannsen, Kirsten L; Zoffmann, Vibeke

    2017-08-29

    Based on the Family-Centred Care philosophy, skin-to-skin contact is a key activity in neonatal care, and use of this practice is increasing also with extremely preterm infants. Little is known about parents' immediate experiences of and readiness for skin-to-skin contact, while their fragile infant may still not be 'on safe ground'. Knowledge about parents' experiences might reduce doubt and reluctance among healthcare professionals to use skin-to-skin contact with extremely preterm infants and thus increase its dissemination in practice. To explore parents' immediate experiences of skin-to-skin contact with extremely preterm infants parents after skin-to-skin contact with their extremely preterm infants analysed using inductive thematic analysis. Parents' experiences were related to the process before, during and after skin-to-skin contact and moved from ambivalence to appreciating skin-to-skin contact as beneficial for both parents and infant. The process comprised three stages: (i) overcoming ambivalence through professional support and personal experience; (ii) proximity creating parental feelings and an inner need to provide care; (iii) feeling useful as a parent and realising the importance of skin-to-skin contact. Having repeatedly gone through stages 2 and 3, parents developed an overall confidence in the value of bonding, independent of the infant's survival. Parents progressed from ambivalence to a feeling of fundamental mutual needs for skin-to-skin contact. Parents found the bonding facilitated by skin-to-skin contact to be valuable, regardless of the infant's survival. © 2017 Nordic College of Caring Science.

  18. User's Guide To CHEAP0 II-Economic Analysis of Stand Prognosis Model Outputs

    Science.gov (United States)

    Joseph E. Horn; E. Lee Medema; Ervin G. Schuster

    1986-01-01

    CHEAP0 II provides supplemental economic analysis capability for users of version 5.1 of the Stand Prognosis Model, including recent regeneration and insect outbreak extensions. Although patterned after the old CHEAP0 model, CHEAP0 II has more features and analytic capabilities, especially for analysis of existing and uneven-aged stands....

  19. Contact Dermatitis Associated With Skin Cleansers: Retrospective Analysis of North American Contact Dermatitis Group Data 2000-2014.

    Science.gov (United States)

    Warshaw, Erin M; Goodier, Molly C; DeKoven, Joel G; Maibach, Howard I; Taylor, James S; Sasseville, Denis; Belsito, Donald V; Fowler, Joseph F; Fransway, Anthony F; DeLeo, Vincent A; Marks, James G; Pratt, Melanie D; Mathias, Toby; Zirwas, Matthew J; Zug, Kathryn A

    There is limited information regarding contact dermatitis (CD) associated with skin cleansers (SCs). The aim of the study was to evaluate the prevalence of allergic patch test (APT) reactions and irritant CD (ICD) associated with SCs. A retrospective cross-sectional analysis was performed using North American Contact Dermatitis Group data, 2000-2014. Of 32,945 tested patients, 1069 (3.24%) had either APT reaction or ICD associated with SCs. Of these, 692 (64.7%) had APT reaction only, 350 (32.7%) had ICD only, and 27 (2.5%) had both. Individuals with APT reaction and/or ICD were more likely to have occupationally related skin disease (relative risk [RR] = 3.8 [95% confidence interval {CI} = 3.3-4.5] for APT reaction and 10.0 [95% CI = 8.2-12.2] for ICD, respectively, P dermatitis (RR = 1.3 [95% CI = 1.1-1.6], P ≤ 0.001). Irritant CD was strongly associated with hand dermatitis (RR = 6.2 [95% CI = 5.2-7.3], P < 0.0001). More than 50 allergens were associated with SCs including quaternium-15 (11.2%), cocamidopropyl betaine (9.5%), methylchloroisothiazolinone/methylisothiazolinone (8.4%), coconut diethanolamide (7.9%), fragrance mix I (7.7%), Myroxylon pereirae (5.9%), 4-chloro-3,5-xylenol (5.8%), amidoamine (5.5%), and formaldehyde (4.4%). Many allergens, especially preservatives and surfactants, were associated with SCs. Most cases involved the hands and were occupationally related.

  20. Identification of Microorganisms Isolated From Counterfeit and Unapproved Decorative Contact Lenses.

    Science.gov (United States)

    Land, Adrian D; Penno, Katie L; Brzezinski, Jennifer L

    2018-03-01

    All contact lenses (corrective/noncorrective) are considered Class II or Class III medical devices under the Federal Food, Drug, and Cosmetic Act, which also states that contact lenses can only be obtained with a prescription. The Forensic Chemistry Center of the US Food & Drug Administration has examined over 300 decorative, noncorrective contact lenses obtained without a prescription. Our observations indicate that 60% of the counterfeit lenses and 27% of the unapproved lenses examined were positive for microbial contamination. Twenty-nine different brands of noncorrective contact lenses were examined, and 48% of them had at least one sample positive for microbial contamination. Each microorganism was further identified using DNA sequencing. Contaminated contact lenses are associated with numerous health risks, including ocular infections and conjunctivitis leading to permanent visual impairment or blindness. These results support the contention that acquiring contact lenses without a prescription is a considerable threat to consumer health and safety. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  1. Clustering of contacts relevant to the spread of infectious disease.

    Science.gov (United States)

    Xiao, Xiong; van Hoek, Albert Jan; Kenward, Michael G; Melegaro, Alessia; Jit, Mark

    2016-12-01

    Infectious disease spread depends on contact rates between infectious and susceptible individuals. Transmission models are commonly informed using empirically collected contact data, but the relevance of different contact types to transmission is still not well understood. Some studies select contacts based on a single characteristic such as proximity (physical/non-physical), location, duration or frequency. This study aimed to explore whether clusters of contacts similar to each other across multiple characteristics could better explain disease transmission. Individual contact data from the POLYMOD survey in Poland, Great Britain, Belgium, Finland and Italy were grouped into clusters by the k medoids clustering algorithm with a Manhattan distance metric to stratify contacts using all four characteristics. Contact clusters were then used to fit a transmission model to sero-epidemiological data for varicella-zoster virus (VZV) in each country. Across the five countries, 9-15 clusters were found to optimise both quality of clustering (measured using average silhouette width) and quality of fit (measured using several information criteria). Of these, 2-3 clusters were most relevant to VZV transmission, characterised by (i) 1-2 clusters of age-assortative contacts in schools, (ii) a cluster of less age-assortative contacts in non-school settings. Quality of fit was similar to using contacts stratified by a single characteristic, providing validation that single stratifications are appropriate. However, using clustering to stratify contacts using multiple characteristics provided insight into the structures underlying infection transmission, particularly the role of age-assortative contacts, involving school age children, for VZV transmission between households. Copyright © 2016 The Author(s). Published by Elsevier B.V. All rights reserved.

  2. Occupations at risk of developing contact allergy to isothiazolinones in Danish contact dermatitis patients

    DEFF Research Database (Denmark)

    Schwensen, Jakob F; Menné, Torkil; Andersen, Klaus E

    2014-01-01

    , MCI/MI and BIT between 2009 and 2013 were included. RESULTS: MI contact allergy showed a significantly increased trend in prevalence from 1.8% in 2009 to 4.2% in 2012 (p dermatitis mainly drove the increase in 2012. Adjusted logistic regression analysis showed that MI...... sensitization was significantly associated with occupational exposures, hand and facial dermatitis, age > 40 years, and the occupational groups of tile setters/terrazzo workers, machine operators, and painters. MCI/MI contact allergy was significantly associated with the following high-risk occupations......BACKGROUND: In recent years, the prevalence of contact allergy to isothiazolinones has reached epidemic levels. Few studies have presented data on occupations at risk of developing contact allergy to isothiazolinones. OBJECTIVES: To present demographics and examine risk factors for sensitization...

  3. Efficiency of Chitosan for the Removal of Pb (II, Fe (II and Cu (II Ions from Aqueous Solutions

    Directory of Open Access Journals (Sweden)

    Soheil Sobhanardakani

    2014-09-01

    Full Text Available Background: Heavy metals have been recognized as harmful environmental pollutant known to produce highly toxic effects on different organs and systems of both humans and animals. The aim of this paper is to evaluate the adsorption potential of chitosan for the removal of Pb(II, Fe(II and Cu(II ions from aqueous solutions. Methods: This study was conducted in laboratory scale. In this paper chitosan has been used as an adsorbent for the removal of Pb(II, Fe(II and Cu(II from aqueous solution. In batch tests, the effects of parameters like pH solution (1.0-8.0, initial metal concentrations (100-1000 mgL-1, contact time (5.0-150 min and adsorbent dose (1.0-7.0 g on the adsorption process were studied. Results: The results showed that the adsorption of Pb(II, Fe(II and Cu(II ions on chitosan strongly depends on pH. The experimental isothermal data were analyzed using the Langmuir and Freundlich equations and it was found that the removal process followed the Langmuir isotherm and maximum adsorption capacity for the adsorption of Pb(II, Fe(II and Cu(II ions by the chitosan were 55.5mg g−1, 71.4 mg g−1 and 59 mg g−1, respectively, under equilibrium conditions at 25±1 ºC. The adsorption process was found to be well described by the pseudo-second-order rate model. Conclusion: The obtained results showed that chitosan is a readily, available, economic adsorbent and was found suitable for removing Pb(II, Fe(II and Cu(II ions from aqueous solution.

  4. Preparation of Schiff s base complexes of Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Cd(II) and their spectroscopic, magnetic, thermal, and antifungal studies

    International Nuclear Information System (INIS)

    Parekh, H.M.; Patel, M.N.

    2006-01-01

    The potassium salt of salicylidene-DL-alanine (KHL), bis(benzylidene)ethylenediamine (A 1 ), thiophene-o-carboxaldene-p-toluidine (A 2 ), and its metal complexes of the formula [(M II (L)(A)(H 2 O)] (M=Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Cd(II); A = A 1 or A 2 ) are prepared. They are characterized by elemental analysis, magnetic susceptibility measurements, thermogravimetric analysis, and infrared and electronic spectral studies. The electronic spectral and magnetic moment data suggest an octahedral geometry for the complexes. All of these complexes, metal nitrates, fungicides (bavistin and emcarb), and ligands are screened for their antifungal activity against Aspergillus niger, Fusarium oxysporum, and Aspergillus flavus using a plate poison technique. The complexes show higher activity than those of the free ligands, metal nitrate, and the control (DMSO) and moderate activity against bavistin and emcarb [ru

  5. Equilibrium and kinetic studies of Pb(II, Cd(II and Zn(II sorption by Lagenaria vulgaris shell

    Directory of Open Access Journals (Sweden)

    Mitić-Stojanović Dragana-Linda

    2012-01-01

    Full Text Available The sorption of lead, cadmium and zinc ions from aqueous solution by Lagenaria vulgaris shell biosorbent (LVB in batch system was investigated. The effect of relevant parameters such as contact time, biosorbent dosage and initial metal ions concentration was evaluated. The Pb(II, Cd(II and Zn(II sorption equilibrium (when 98% of initial metal ions were sorbed was attained within 15, 20 and 25 min, respectively. The pseudo first, pseudo-second order, Chrastil’s and intra-particle diffusion models were used to describe the kinetic data. The experimental data fitted the pseudo-second order kinetic model and intra-particle diffusion model. Removal efficiency of lead(II, cadmium(II and zinc(II ions rapidly increased with increasing biosorbent dose from 0.5 to 8.0 g dm-3. Optimal biosorbent dose was set to 4.0 g dm-3. An increase in the initial metal concentration increases the sorption capacity. The sorption data of investigated metal ions are fitted to Langmuir, Freundlich and Temkin isotherm models. Langmuir model best fitted the equilibrium data (r2 > 0.99. Maximal sorption capacities of LVB for Pb(II, Cd(II and Zn(II at 25.0±0.5°C were 0.130, 0.103 and 0.098 mM g-1, respectively. The desorption experiments showed that the LVB could be reused for six cycles with a minimum loss of the initial sorption capacity.

  6. Spectroscopic and thermal degradation behavior of Mg(II, Ca(II, Ba(II and Sr(II complexes with paracetamol drug

    Directory of Open Access Journals (Sweden)

    Moamen S. Refat

    2017-05-01

    Full Text Available Complexes of Mg(II, Ca(II, Ba(II and Sr(II with paracetamol drug were synthesized and characterized by elemental analysis, conductivity, UV–Vis, IR, and 1H NMR spectroscopy and thermal analysis, as well as screened for antimicrobial activity. The IR spectral data suggested that the ligand behaves as paracetamol behaves as a neutral bidentate ligand coordinated to the metal ions via the lone pair of electrons of nitrogen and carbonyl-O atoms of the amide group. From the microanalytical data, the stoichiometry of the complexes reacts with Mg(II, Ca(II, Ba(II and Sr(II by molar ratios (2:1 (paracetamol:metal ion. The thermal behavior (TG/DTG of the complexes was studied. The ligand and their metal complexes were screened against both of antibacterial and fungicidal activities.

  7. Comparison of proximal contacts of class II resin composite restorations in vitro.

    NARCIS (Netherlands)

    Loomans, B.A.C.; Opdam, N.J.M.; Roeters, F.J.M.; Bronkhorst, E.M.; Burgersdijk, R.C.W.

    2006-01-01

    This study investigated the tightness of the proximal contact when placing posterior resin composite restorations with circumferential and sectional matrix systems in an in vitro model using a special measuring device (Tooth Pressure Meter). A manikin model was used with an artificial first molar in

  8. RECOVERY OF COPPER(II AND CHROMIUM(III FROM NITRATE MEDIUM WITH SALICYLIDENEANILINE DISSOLVED IN 1-OCTANOL

    Directory of Open Access Journals (Sweden)

    A. Guerdouh

    2016-05-01

    Full Text Available The solvent extraction of copper(II and chromium(III from nitrate medium with salicylideneaniline (HL is studied as a function of various parameters: pH, concentration of salicylideneaniline, contact time and the nature of anoin (nitrate and sulfate in aqueous phase. Chromium(III is not extracted by salicylideneaniline  diluted in 1-octanol. Copper(II is only extracted by salicylideneaniline and it was found that the highest extractability achieved to 95% at pH 4.9, The stoichiometry of the extracted species was determined by using the method of slope analysis. Elemental analysis, UV–vis and IR-spectra were used to confirm the structure. It is found that the copper (II is extracted as CuL2.2H2O Their equilibrium constant, distribution coefficient, percentage extraction (%E and free energy are also calculated.

  9. Occupational contact urticaria and protein contact dermatitis.

    Science.gov (United States)

    Doutre, Marie-Sylvie

    2005-01-01

    Irritant dermatitis and eczema are the most prevalent occupational skin diseases. Less common are immediate contact reactions such as contact urticaria and protein contact dermatitis. Occupational contact urticaria can be subdivided into two categories, immunological and non immunological. However, some agents can induce these two types of reactions. Contact urticaria to natural rubber latex is particularly frequent among health care personnel, but contact urticaria to a wide variety of other substances occurs in many other occupations. Among those at risk are cooks, bakers, butchers, restaurant personnel, veterinarians, hairdressers, florists, gardeners, and forestry workers. Protein contact dermatitis in some of these occupations is caused principally by proteins of animal or plant origin, especially among individuals with a history of atopic dermatitis. Diagnosis requires careful interrogation, clinical examination and skin tests (open tests and prick tests with immediate lecture) to identify a particular contact allergen.

  10. Elastic–plastic adhesive contact of non-Gaussian rough surfaces

    Indian Academy of Sciences (India)

    Adhesion; asymmetric roughness; elastic–plastic contact; non-Gaussian rough surfaces. ... model of contact deformation that is based on accurate Finite Element Analysis (FEA) of an elastic–plastic single asperity contact. ... Sadhana | News.

  11. Policy Analysis on Growth and Employment - PAGE II | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Policy Analysis on Growth and Employment - PAGE II. This project by the Partnership for Economic Policy (PEP) will support quality ... The project is supported by the UK's Department for International Development, and additional funding is ...

  12. Ohmic contacts to InN-based materials

    Directory of Open Access Journals (Sweden)

    Sai P. O.

    2016-10-01

    Full Text Available The key aspects of ohmic contact formation to InN-based materials were investigated. Detailed analysis of studies conducted over the past three decades, allows determining the basic principles of such contacts. The contact structure properties and optimal conditions for them are presented. Different types of metallization are considered, the advantages and disadvantages of each are determined, including the basic requirements that such contact must meet. There is emphasis on the using multilayer metallization with the barrier layers. In the case of the InAlN/GaN systems, the general approaches of forming ohmic contacts were considered.

  13. Synthesis and spectral studies of manganese(II), cobalt(II), nickel(II), copper(II), zinc(II), cadmium(II) and mercury(II) complexes of 4-oxo-4H-1-benzopyran-3-carboxaldehyde hydrazone derivatives

    International Nuclear Information System (INIS)

    Nawar, N.; Khattab, M.A.; Bekheit, M.M.; El-Kaddah, A.H.

    1996-01-01

    A few complexes of Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and Hg(II) with 4-oxo-4H-1-benzopyran-3-(carboxaldehyde-4-chlorobenzylhydrazone) (BCBH) and 4-oxo-4H-1-benzopyran-3-(carboxaldehyde-4-methylbenzylhydrazone) (BMBH) have been synthesised and characterized by elemental analysis, molar conductivities, magnetic measurements and infrared (IR) and visible spectral studies. The IR spectra show that BCBH and BMBH behave as bidentate ligands either in the keto or enol form. (author). 24 refs., 2 tabs

  14. Contact stresses, pressure and area in a fixed-bearing total ankle replacement: a finite element analysis.

    Science.gov (United States)

    Martinelli, Nicolo; Baretta, Silvia; Pagano, Jenny; Bianchi, Alberto; Villa, Tomaso; Casaroli, Gloria; Galbusera, Fabio

    2017-11-25

    Mobile-bearing ankle implants with good clinical results continued to increase the popularity of total ankle arthroplasty to address endstage ankle osteoarthritis preserving joint movement. Alternative solutions used fixed-bearing designs, which increase stability and reduce the risk of bearing dislocation, but with a theoretical increase of contact stresses leading to a higher polyethylene wear. The purpose of this study was to investigate the contact stresses, pressure and area in the polyethylene component of a new total ankle replacement with a fixed-bearing design, using 3D finite element analysis. A three-dimensional finite element model of the Zimmer Trabecular Metal Total Ankle was developed and assembled based on computed tomography images. Three different sizes of the polyethylene insert were modeled, and a finite element analysis was conducted to investigate the contact pressure, the von Mises stresses and the contact area of the polyethylene component during the stance phase of the gait cycle. The peak value of pressure was found in the anterior region of the articulating surface, where it reached 19.8 MPa at 40% of the gait cycle. The average contact pressure during the stance phase was 6.9 MPa. The maximum von Mises stress of 14.1 MPa was reached at 40% of the gait cycle in the anterior section. In the central section, the maximum von Mises stress of 10.8 MPa was reached at 37% of the gait cycle, whereas in the posterior section the maximum stress of 5.4 MPa was reached at the end of the stance phase. The new fixed-bearing total ankle replacement showed a safe mechanical behavior and many clinical advantages. However, advanced models to quantitatively estimate the wear are need. To the light of the clinical advantages, we conclude that the presented prosthesis is a good alternative to the other products present in the market.

  15. Pb(II) and Cd(II) removal from aqueous solution, shipyard wastewater, and landfill leachate by modified Rhizopus oryzae biomass

    Science.gov (United States)

    Naeimi, Behrouz; Foroutan, Rauf; Ahmadi, Bahram; Sadeghzadeh, Farzaneh; Ramavandi, Bahman

    2018-04-01

    This study was designed to remove Pb(II) and Cd(II) from aqueous solution, shipyard wastewater, and sanitary landfill leachate using an alkaline-modified Rhizopus oryzae biomass. According to the Fourier transform infrared test, different functional groups like O–H, N–H, C=O, and P–O were detected in the bioadsorbent. The x-ray fluorescence (XRF) analysis showed that CaO, P2O3, and SO3 oxides have the highest content in the bioadsorbent. The surface area of modified Rhizopus oryzae was obtained as 20.32 m2 g‑1. The effect of initial pH, temperature, contact time, and bioadsorbent dose on the metals removal was discussed. At optimal conditions, maximum Pb(II) and Cd(II) removal was obtained 95.66% and 94.55%, respectively. Freundlich model was well- accurately described the equilibrium data. Among four studied models, the pseudo-second-order was better able to describe the kinetic behavior of the bioadsorption process. The amount of enthalpy, free energy of Gibbs, and entropy parameters indicated that the bioadsorption process of studied heavy metals is negative, exothermic, and spontaneous. The amount of heavy metals in a shipyard wastewater and sanitary landfill leachate was significantly decreased by using the developed bioadsorbent.

  16. Design, Generation and Tooth Contact Analysis (TCA) of Asymmetric Face Gear Drive With Modified Geometry

    Science.gov (United States)

    Litvin, Faydor L.; Fuentes, Alfonso; Hawkins, J. M.; Handschuh, Robert F.

    2001-01-01

    A new type of face gear drive for application in transmissions, particularly in helicopters, has been developed. The new geometry differs from the existing geometry by application of asymmetric profiles and double-crowned pinion of the face gear mesh. The paper describes the computerized design, simulation of meshing and contact, and stress analysis by finite element method. Special purpose computer codes have been developed to conduct the analysis. The analysis of this new type of face gear is illustrated with a numerical example.

  17. Review of prediction for thermal contact resistance

    Institute of Scientific and Technical Information of China (English)

    2010-01-01

    Theoretical prediction research on thermal contact resistance is reviewed in this paper. In general, modeling or simulating the thermal contact resistance involves several aspects, including the descriptions of surface topography, the analysis of micro mechanical deformation, and the thermal models. Some key problems are proposed for accurately predicting the thermal resistance of two solid contact surfaces. We provide a perspective on further promising research, which would be beneficial to understanding mechanisms and engineering applications of the thermal contact resistance in heat transport phenomena.

  18. Deep functional analysis of synII, a 770-kilobase synthetic yeast chromosome.

    Science.gov (United States)

    Shen, Yue; Wang, Yun; Chen, Tai; Gao, Feng; Gong, Jianhui; Abramczyk, Dariusz; Walker, Roy; Zhao, Hongcui; Chen, Shihong; Liu, Wei; Luo, Yisha; Müller, Carolin A; Paul-Dubois-Taine, Adrien; Alver, Bonnie; Stracquadanio, Giovanni; Mitchell, Leslie A; Luo, Zhouqing; Fan, Yanqun; Zhou, Baojin; Wen, Bo; Tan, Fengji; Wang, Yujia; Zi, Jin; Xie, Zexiong; Li, Bingzhi; Yang, Kun; Richardson, Sarah M; Jiang, Hui; French, Christopher E; Nieduszynski, Conrad A; Koszul, Romain; Marston, Adele L; Yuan, Yingjin; Wang, Jian; Bader, Joel S; Dai, Junbiao; Boeke, Jef D; Xu, Xun; Cai, Yizhi; Yang, Huanming

    2017-03-10

    Here, we report the successful design, construction, and characterization of a 770-kilobase synthetic yeast chromosome II (synII). Our study incorporates characterization at multiple levels-including phenomics, transcriptomics, proteomics, chromosome segregation, and replication analysis-to provide a thorough and comprehensive analysis of a synthetic chromosome. Our Trans-Omics analyses reveal a modest but potentially relevant pervasive up-regulation of translational machinery observed in synII, mainly caused by the deletion of 13 transfer RNAs. By both complementation assays and SCRaMbLE (synthetic chromosome rearrangement and modification by loxP -mediated evolution), we targeted and debugged the origin of a growth defect at 37°C in glycerol medium, which is related to misregulation of the high-osmolarity glycerol response. Despite the subtle differences, the synII strain shows highly consistent biological processes comparable to the native strain. Copyright © 2017, American Association for the Advancement of Science.

  19. Spectroscopic and thermal degradation behavior of Mg(II), Ca(II), Ba(II) and Sr(II) complexes with paracetamol drug

    OpenAIRE

    Moamen S. Refat; Gehad G. Mohamed; Mohamed Y. El-Sayed; Hamada M.A. Killa; Hammad Fetooh

    2017-01-01

    Complexes of Mg(II), Ca(II), Ba(II) and Sr(II) with paracetamol drug were synthesized and characterized by elemental analysis, conductivity, UV–Vis, IR, and 1H NMR spectroscopy and thermal analysis, as well as screened for antimicrobial activity. The IR spectral data suggested that the ligand behaves as paracetamol behaves as a neutral bidentate ligand coordinated to the metal ions via the lone pair of electrons of nitrogen and carbonyl-O atoms of the amide group. From the microanalytical dat...

  20. Scalable algorithms for contact problems

    CERN Document Server

    Dostál, Zdeněk; Sadowská, Marie; Vondrák, Vít

    2016-01-01

    This book presents a comprehensive and self-contained treatment of the authors’ newly developed scalable algorithms for the solutions of multibody contact problems of linear elasticity. The brand new feature of these algorithms is theoretically supported numerical scalability and parallel scalability demonstrated on problems discretized by billions of degrees of freedom. The theory supports solving multibody frictionless contact problems, contact problems with possibly orthotropic Tresca’s friction, and transient contact problems. It covers BEM discretization, jumping coefficients, floating bodies, mortar non-penetration conditions, etc. The exposition is divided into four parts, the first of which reviews appropriate facets of linear algebra, optimization, and analysis. The most important algorithms and optimality results are presented in the third part of the volume. The presentation is complete, including continuous formulation, discretization, decomposition, optimality results, and numerical experimen...

  1. Selection of contact bearing couple materials for hip prosthesis using finite element analysis under static conditions

    Science.gov (United States)

    Arirajan, K. A.; Chockalingam, K.; Vignesh, C.

    2018-04-01

    Implants are the artificial parts to replace the missing bones or joints in human anatomy to give mechanical support. Hip joint replacement is an important issue in orthopaedic surgery. The main concern limiting the long-run success of the total hip replacement is the limited service life. Hip replacement technique is widely used in replacing the femur head and acetabular cup by materials that are highly biocompatible. The success of the artificial hip replacement depends upon proper material selection, structure, and shape of the hip prosthesis. Many orthopaedic analyses have been tried with different materials, but ended with partial success on the application side. It is a critical task for selecting the best material pair in the hip prosthesis design. This work develops the finite element analysis of an artificial hip implant to study highest von Mises stress, contact pressure and elastic strain occurs for the dissimilar material combination. The different bearing couple considered for the analysis are Metal on Metal, Metal on Plastic, Metal on Ceramic, Ceramic on Plastic, Ceramic on Ceramic combinations. The analysis is carried out at different static positions of a human (i.e) standing, sitting. The results reveals that the combination with metal in contact with plastic (i.e) Titanium femoral head paired with Ultra High Molecular Weight Poly Ethylene acetabular cup reduces maximum von Mises stress and also it gives lowest contact pressure than other combination of bearing couples.

  2. Frictionless contact analysis of a functionally graded piezoelectric layered half-plane

    International Nuclear Information System (INIS)

    Ke Liaoliang; Yang Jie; Kitipornchai, Sritawat; Wang Yuesheng

    2008-01-01

    This paper investigates the frictionless contact problem of a layered half-plane made of functionally graded piezoelectric material (FGPM) in the plane strain state under the action of a rigid punch whose shape may be flat, triangular or cylindrical. It is assumed that the punch is a perfect electrical insulator with zero electric charge distribution. The electroelastic properties of the FGPM layer vary exponentially along the thickness direction. By using the Fourier integral transform technique, the problem is reduced to a Cauchy singular integral equation which is then numerically solved to determine the contact pressure, contact region, maximum indentation depth, normal stress, electrical potential and electric displacement fields. The stress intensity factor is also given to quantitatively characterize the singularity behavior of the contact pressure at the ends of a flat and triangular punch. Numerical results show that both the material property gradient of the FGPM layer and the punch geometry have a significant influence on the contact performance of the FGPM layered half-plane

  3. A Comparative Study on the Sorption Characteristics of Pb(II and Hg(II onto Activated Carbon

    Directory of Open Access Journals (Sweden)

    N. Muthulakshmi Andal

    2010-01-01

    Full Text Available Biosorption equilibrium and kinetics of Pb(II and Hg(II on coconut shell carbon (CSC were investigated by batch equilibration method. The effects of pH, adsorbent dosage, contact time, temperature and initial concentration of Pb(II and Hg(II on the activated carbon of coconut shell wastes were studied. Maximum adsorption of Pb(II occurred at pH 4.5 and Hg(II at pH 6. The sorptive mechanism followed the pseudo second order kinetics. The equilibrium data were analysed by Langmuir, Freundlich and Dubinin-Radushkevich isotherm models. The equilibration data fitted well with both Langmuir and Freundlich isotherm model. The Langmuir adsorption capacity for Pb(II was greater than Hg(II. The mean free energy of adsorption calculated from Dubinin-Radushkevich (D-R isotherm model indicated that the adsorption of metal ions was found to be by chemical ion exchange. Thermodynamic parameter showed that the sorption process of Pb(II onto SDC was feasible, spontaneous and endothermic under studied conditions. A comparison was evaluated for the two metals.

  4. Biologically active new Fe(II, Co(II, Ni(II, Cu(II, Zn(II and Cd(II complexes of N-(2-thienylmethylenemethanamine

    Directory of Open Access Journals (Sweden)

    C. SPÎNU

    2008-04-01

    Full Text Available Iron(II, cobalt(II, nickel (II, copper (II, zinc(II and cadmium(II complexes of the type ML2Cl2, where M is a metal and L is the Schiff base N-(2-thienylmethylenemethanamine (TNAM formed by the condensation of 2-thiophenecarboxaldehyde and methylamine, were prepared and characterized by elemental analysis as well as magnetic and spectroscopic measurements. The elemental analyses suggest the stoichiometry to be 1:2 (metal:ligand. Magnetic susceptibility data coupled with electronic, ESR and Mössbauer spectra suggest a distorted octahedral structure for the Fe(II, Co(II and Ni(II complexes, a square-planar geometry for the Cu(II compound and a tetrahedral geometry for the Zn(II and Cd(II complexes. The infrared and NMR spectra of the complexes agree with co-ordination to the central metal atom through nitrogen and sulphur atoms. Conductance measurements suggest the non-electrolytic nature of the complexes, except for the Cu(II, Zn(II and Cd(II complexes, which are 1:2 electrolytes. The Schiff base and its metal chelates were screened for their biological activity against Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa and the metal chelates were found to possess better antibacterial activity than that of the uncomplexed Schiff base.

  5. In vitro evaluation of resonance frequency analysis values to different implant contact ratio and stiffness of surrounding material.

    Science.gov (United States)

    Kwak, Mu-Seung; Kim, Seok-Gyu

    2013-11-01

    The present study was aimed to evaluate the influence of implant contact ratio and stiffness of implant-surrounding materials on the resonance frequency analysis (RFA) values. Seventy resin blocks that had the different amounts (100, 50, 30, 15%) of resin-implant contact (RIC) were fabricated. Ten silicone putty blocks with 100% silicone-implant contact were also made. The implants with Ø5.0 mm × 13.0 mm were placed on eighty specimen blocks. The RFA value was measured on the transducer that was connected to each implant by Osstell Mentor. Kruskal-Wallis and Scheffe's tests (α=.05) were done for statistical analysis. The control resin group with 100% RIC had the highest RFA value of 83.9, which was significantly different only from the resin group with 15% RIC among the resin groups. The silicone putty group with 100% contact had the lowest RFA value of 36.6 and showed statistically significant differences from the resin groups. Within the limitations of this in vitro study, there was no significant difference in the RFA values among the resin groups with different RIC's except when the RIC difference was more than 85%. A significant increase in the RFA value was observed related to the increase in stiffness of material around implant.

  6. Association between atopic dermatitis and contact sensitization

    DEFF Research Database (Denmark)

    Hamann, Carsten R; Hamann, Dathan; Egeberg, Alexander

    2017-01-01

    BACKGROUND: It is unclear whether patients with atopic dermatitis (AD) have an altered prevalence or risk for contact sensitization. Increased exposure to chemicals in topical products together with impaired skin barrier function suggest a higher risk, whereas the immune profile suggests a lower...... contact dermatitis is suspected....... risk. OBJECTIVE: To perform a systematic review and meta-analysis of the association between AD and contact sensitization. METHODS: The PubMed/Medline, Embase, and Cochrane databases were searched for articles that reported on contact sensitization in individuals with and without AD. RESULTS...

  7. Analysis of deep learning methods for blind protein contact prediction in CASP12.

    Science.gov (United States)

    Wang, Sheng; Sun, Siqi; Xu, Jinbo

    2018-03-01

    Here we present the results of protein contact prediction achieved in CASP12 by our RaptorX-Contact server, which is an early implementation of our deep learning method for contact prediction. On a set of 38 free-modeling target domains with a median family size of around 58 effective sequences, our server obtained an average top L/5 long- and medium-range contact accuracy of 47% and 44%, respectively (L = length). A complete implementation has an average accuracy of 59% and 57%, respectively. Our deep learning method formulates contact prediction as a pixel-level image labeling problem and simultaneously predicts all residue pairs of a protein using a combination of two deep residual neural networks, taking as input the residue conservation information, predicted secondary structure and solvent accessibility, contact potential, and coevolution information. Our approach differs from existing methods mainly in (1) formulating contact prediction as a pixel-level image labeling problem instead of an image-level classification problem; (2) simultaneously predicting all contacts of an individual protein to make effective use of contact occurrence patterns; and (3) integrating both one-dimensional and two-dimensional deep convolutional neural networks to effectively learn complex sequence-structure relationship including high-order residue correlation. This paper discusses the RaptorX-Contact pipeline, both contact prediction and contact-based folding results, and finally the strength and weakness of our method. © 2017 Wiley Periodicals, Inc.

  8. Analysis of Wetting and Contact Angle Hysteresis on Chemically Patterned Surfaces

    KAUST Repository

    Xu, Xianmin; Wang, Xiaoping

    2011-01-01

    Wetting and contact angle hysteresis on chemically patterned surfaces in two dimensionsare analyzed from a stationary phase-field model for immiscible two phase fluids. We first study the sharp-interface limit of the model by the method of matched asymptotic expansions. We then justify the results rigorously by the γ-convergence theory for the related variational problem and study the properties of the limiting minimizers. The results also provide a clear geometric picture of the equilibrium configuration of the interface. This enables us to explicitly calculate the total surface energy for the two phase systems on chemically patterned surfaces with simple geometries, namely the two phase flow in a channel and the drop spreading. By considering the quasi-staticmotion of the interface described by the change of volume (or volume fraction), we can follow the change-of-energy landscape which also reveals the mechanism for the stick-slip motion of the interface and contact angle hysteresis on the chemically patterned surfaces. As the interface passes throughpatterned surfaces, we observe not only stick-slip of the interface and switching of the contact angles but also the hysteresis of contact point and contact angle. Furthermore, as the size of the patternde creases to zero, the stick-slip becomes weaker but the hysteresis becomes stronger in the sense that one observes either the advancing contact angle or the receding contact angle (when the interface ismoving in the opposite direction) without the switching in between. © 2011 Society for Industrial and Applied Mathematics.

  9. ChemCam-like Spectrometer for Non-Contact Measurements of Key Isotopes, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This project addresses the need for a non-contact instrument capable of measuring the isotopic ratios O-18/O-16 and D/H from water ice and other solid materials...

  10. Dynamic Model of Contact Interface between Stator and Rotor

    Directory of Open Access Journals (Sweden)

    ZengHui Zhao

    2013-01-01

    Full Text Available Based on the equivalent principle, a linear spring contact model was established for the friction layer between stator and rotor. Different contact conditions were described by a distance index δ. Detailed analysis of the nonlinear contact behavior especially the static and dynamic slipping was carried on using a space-time equation. A contact deflection angle was proposed to quantitatively express the influence of friction force on the output performance. A more precision simulation model was established based on the theoretical analysis, and influences of different preload pressures and elastic modulus Em of friction layer on output performance were analyzed. The results showed the simulation results had very good consistency with experimental results, and the model could well reflect the output characteristics of contact interface.

  11. Loading and Contact Stress Analysis on the Thread Teeth in Tubing and Casing Premium Threaded Connection

    Directory of Open Access Journals (Sweden)

    Honglin Xu

    2014-01-01

    Full Text Available Loading and contact stress distribution on the thread teeth in tubing and casing premium threaded connections are of great importance for design optimization, pretightening force control, and thread failure prevention. This paper proposes an analytical method based on the elastic mechanics. This is quite different from other papers, which mainly rely on finite element analysis. The differential equation of load distribution on the thread teeth was established according to equal pitch of the engaged thread after deformation and solved by finite difference method. Furthermore, the relation between load acting on each engaged thread and mean contact stress on its load flank is set up based on the geometric description of thread surface. By comparison, this new analytical method with the finite element analysis for a modified API 177.8 mm premium threaded connection is approved. Comparison of the contact stress on the last engaged thread between analytical model and FEM shows that the accuracy of analytical model will decline with the increase of pretightening force after the material enters into plastic deformation. However, the analytical method can meet the needs of engineering to some extent because its relative error is about 6.2%~18.1% for the in-service level of pretightening force.

  12. Tooth contact analysis of spur gears. Part 2-Analysis of modified gears

    Directory of Open Access Journals (Sweden)

    Pop Nicolae

    2017-01-01

    Full Text Available The misalignment between gears axes or direction deviations of teeth leads accentuate the edge effect, Modified spur gears which localize the initial bearing contact by proper modifications of the lead profile are used to avoid the development of the edge effect. A semi-analytical method was involved to find the contact area, pressures distribution and depth stresses states for the standard gears and gears with modified lead profile. The lead modifications concerned the crowning of the flank surface and the end relieving of the tooth flanks, both being applied to the pinion teeth only.

  13. A meta-analysis of studies on cosmetically tinted soft contact lenses

    Directory of Open Access Journals (Sweden)

    Rah MJ

    2013-10-01

    .Conclusion: The cosmetically tinted lenses evaluated in this meta-analysis appear to be safe when properly prescribed by an eye care professional and used in a compliant manner.Keywords: contact lens, hydrogel, cosmetically tinted contact lens, compliance

  14. Characterization of electroless Au, Pt and Pd contacts on CdTe and ZnTe by RBS and SIMS techniques

    Energy Technology Data Exchange (ETDEWEB)

    Roumie, M. E-mail: mroumie@cnrs.edu.lb; Hageali, M.; Zahraman, K.; Nsouli, B.; Younes, G

    2004-06-01

    Rutherford backscattering spectrometry (RBS) was applied to characterize Au, Pt and Pd contacts on II-VI semiconductor materials, CdTe and ZnTe, used as nuclear detectors. Electroless thin film depositions were prepared by changing the concentration of the reaction solution. Contrary to the deposition reaction time, it was observed that the amount of solution dilution degree had a considerable effect on increasing the thickness of the metal layer. Furthermore, PICTS electrical measurements confirmed the depth profile analysis performed by RBS and SIMS.

  15. Kinetic study on adsorption of Cr(VI), Ni(II), Cd(II) and Pb(II) ions from aqueous solutions using activated carbon prepared from Cucumis melo peel

    Science.gov (United States)

    Manjuladevi, M.; Anitha, R.; Manonmani, S.

    2018-03-01

    The adsorption of Cr(VI), Ni(II), Cd(II) and Pb(II), ions from aqueous solutions by Cucumis melo peel-activated carbon was investigated under laboratory conditions to assess its potential in removing metal ions. The adsorption behavior of metal ions onto CMAC was analyzed with Elovich, intra-particle diffusion rate equations and pseudo-first-order model. The rate constant of Elovich and intra-particle diffusion on CMAC increased in the sequence of Cr(VI) > Ni(II) > Cd(II) > Pb(II). According to the regression coefficients, it was observed that the kinetic adsorption data can fit better by the pseudo-first-order model compared to the second-order Lagergren's model with R 2 > 0.957. The maximum adsorption of metal ions onto the CMAC was found to be 97.95% for Chromium(VI), 98.78% for Ni(II), 98.55% for Pb(II) and 97.96% for Cd(II) at CMAC dose of 250 mg. The adsorption capacities followed the sequence Ni(II) ≈ Pb(II) > Cr(VI) ≈ Cd(II) and Ni(II) > Pb(II) > Cd(II) > Cr(VI). The optimum adsorption conditions selected were adsorbent dosage of 250 mg, pH of 3.0 for Cr(VI) and 6.0 for Ni(II), Cd(II) and Pb(II), adsorption concentration of 250 mg/L and contact time of 180.

  16. Molecular dynamics study of contact mechanics: contact area and interfacial separation from small to full contact

    OpenAIRE

    Yang, C.; Persson, B. N. J.

    2007-01-01

    We report a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. We study the contact area and the interfacial separation from small contact (low load) to full contact (high load). For small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For high load the contact area approaches to the nominal contact area (i.e., complete contact), and the i...

  17. Optimal contact definition for reconstruction of Contact Maps

    Directory of Open Access Journals (Sweden)

    Stehr Henning

    2010-05-01

    Full Text Available Abstract Background Contact maps have been extensively used as a simplified representation of protein structures. They capture most important features of a protein's fold, being preferred by a number of researchers for the description and study of protein structures. Inspired by the model's simplicity many groups have dedicated a considerable amount of effort towards contact prediction as a proxy for protein structure prediction. However a contact map's biological interest is subject to the availability of reliable methods for the 3-dimensional reconstruction of the structure. Results We use an implementation of the well-known distance geometry protocol to build realistic protein 3-dimensional models from contact maps, performing an extensive exploration of many of the parameters involved in the reconstruction process. We try to address the questions: a to what accuracy does a contact map represent its corresponding 3D structure, b what is the best contact map representation with regard to reconstructability and c what is the effect of partial or inaccurate contact information on the 3D structure recovery. Our results suggest that contact maps derived from the application of a distance cutoff of 9 to 11Å around the Cβ atoms constitute the most accurate representation of the 3D structure. The reconstruction process does not provide a single solution to the problem but rather an ensemble of conformations that are within 2Å RMSD of the crystal structure and with lower values for the pairwise average ensemble RMSD. Interestingly it is still possible to recover a structure with partial contact information, although wrong contacts can lead to dramatic loss in reconstruction fidelity. Conclusions Thus contact maps represent a valid approximation to the structures with an accuracy comparable to that of experimental methods. The optimal contact definitions constitute key guidelines for methods based on contact maps such as structure prediction through

  18. Unilateral contact problems variational methods and existence theorems

    CERN Document Server

    Eck, Christof; Krbec, Miroslav

    2005-01-01

    The mathematical analysis of contact problems, with or without friction, is an area where progress depends heavily on the integration of pure and applied mathematics. This book presents the state of the art in the mathematical analysis of unilateral contact problems with friction, along with a major part of the analysis of dynamic contact problems without friction. Much of this monograph emerged from the authors'' research activities over the past 10 years and deals with an approach proven fruitful in many situations. Starting from thin estimates of possible solutions, this approach is based on an approximation of the problem and the proof of a moderate partial regularity of the solution to the approximate problem. This in turn makes use of the shift (or translation) technique - an important yet often overlooked tool for contact problems and other nonlinear problems with limited regularity. The authors pay careful attention to quantification and precise results to get optimal bounds in sufficient conditions f...

  19. Reliability analysis for Atucha II reactor protection system signals

    International Nuclear Information System (INIS)

    Roca, Jose Luis

    1996-01-01

    Atucha II is a 745 MW Argentine Power Nuclear Reactor constructed by ENACE SA, Nuclear Argentine Company for Electrical Power Generation and SIEMENS AG KWU, Erlangen, Germany. A preliminary modular logic analysis of RPS (Reactor Protection System) signals was performed by means of the well known Swedish professional risk and reliability software named Risk-Spectrum taking as a basis a reference signal coded as JR17ER003 which command the two moderator loops valves. From the reliability and behavior knowledge for this reference signal follows an estimation of the reliability for the other 97 RPS signals. Because the preliminary character of this analysis Main Important Measures are not performed at this stage. Reliability is by the statistic value named unavailability predicted. The scope of this analysis is restricted from the measurement elements to the RPS buffer outputs. In the present context only one redundancy is analyzed so in the Instrumentation and Control area there no CCF (Common Cause Failures) present for signals. Finally those unavailability values could be introduced in the failure domain for the posterior complete Atucha II reliability analysis which includes all mechanical and electromechanical features. Also an estimation of the spurious frequency of RPS signals defined as faulty by no trip is performed

  20. Reliability analysis for Atucha II reactor protection system signals

    International Nuclear Information System (INIS)

    Roca, Jose L.

    2000-01-01

    Atucha II is a 745 MW Argentine power nuclear reactor constructed by Nuclear Argentine Company for Electric Power Generation S.A. (ENACE S.A.) and SIEMENS AG KWU, Erlangen, Germany. A preliminary modular logic analysis of RPS (Reactor Protection System) signals was performed by means of the well known Swedish professional risk and reliability software named Risk-Spectrum taking as a basis a reference signal coded as JR17ER003 which command the two moderator loops valves. From the reliability and behavior knowledge for this reference signal follows an estimation of the reliability for the other 97 RPS signals. Because the preliminary character of this analysis Main Important Measures are not performed at this stage. Reliability is by the statistic value named unavailability predicted. The scope of this analysis is restricted from the measurement elements to the RPS buffer outputs. In the present context only one redundancy is analyzed so in the Instrumentation and Control area there no CCF (Common Cause Failures) present for signals. Finally those unavailability values could be introduced in the failure domain for the posterior complete Atucha II reliability analysis which includes all mechanical and electromechanical features. Also an estimation of the spurious frequency of RPS signals defined as faulty by no trip is performed. (author)

  1. Synthesis of Pb(II Imprinted Carboxymethyl Chitosan and the Application as Sorbent for Pb(II Ion

    Directory of Open Access Journals (Sweden)

    Abu Masykur

    2014-07-01

    Full Text Available The aims of this research is to synthesize Pb(II imprinted polymers with carboxymethyl chitosan (CMC as polymers and bisphenol A diglycidyl ether (BADGE as cross-linker (Pb-IIP. Chitosan (CTS, non imprinted polymer (NIP and Pb-IIP were characterized using infrared (IR spectroscopy, X-ray diffraction (XRD, surface area analyzer (SAA, scanning electron microscopy (SEM, and energy dispersive X-ray (EDX spectroscopy. The result showed that the adsorption was optimum at pH 5 and contact time of 250 min. Adsorption of Pb(II ion with all of adsorbents followed pseudo-second order kinetic equation. Adsorption of Pb(II ion on CTS followed Freundlich isotherm while that on NIP and Pb-IIP followed the Langmuir adsorption isotherm. The adsorbent of Pb-IIP give higher capacity than the NIP and CTS. Adsorption capacity of Pb-IIP, NIP and CTS were 167.1, 128.9 and 76.1 mg/g, respectively. NIP gave higher adsorption selectivity for Pb(II/Ni(II and Pb(II/Cu(II, whereas Pb-IIP showed higher adsorption selectivity for Pb(II/Cd(II.The hydrogen bonding dominated interaction between Pb(II ion on NIP and Pb-IIP.

  2. Analysis of a non-contact magnetoelastic torque transducer

    International Nuclear Information System (INIS)

    Andreescu, R.; Spellman, B.; Furlani, E.P.

    2008-01-01

    Results are presented for the performance of a magnetoelastic torque transducer that converts a torque-induced strain in a non-magnetic shaft into changes in a measurable magnetic field. The magnetic field is generated by a thin magnetostrictive layer that is coated onto the circumference of the shaft. The layer is magnetized and has an initial residual strain. The magnetization within the layer rotates in response to changes in the strain which occur when the shaft is torqued. The magnetic field produced by the layer changes with the magnetization and this can be sensed by a magnetometer to monitor the torque on the shaft. In this paper, a phenomenological theory is developed for predicting the performance of the transducer. The theory can be used to predict the magnetic field distribution of the transducer as a function of the physical properties of the magnetic coating, its residual strain, and the applied torque. It enables rapid parametric analysis of transducer performance, which is useful for the development and optimization of novel non-contact torque sensors

  3. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation.

    Science.gov (United States)

    Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin

    2015-03-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (pimplants using micro-CT analysis using a region-based segmentation method.

  4. Contact angle and local wetting at contact line.

    Science.gov (United States)

    Li, Ri; Shan, Yanguang

    2012-11-06

    This theoretical study was motivated by recent experiments and theoretical work that had suggested the dependence of the static contact angle on the local wetting at the triple-phase contact line. We revisit this topic because the static contact angle as a local wetting parameter is still not widely understood and clearly known. To further clarify the relationship of the static contact angle with wetting, two approaches are applied to derive a general equation for the static contact angle of a droplet on a composite surface composed of heterogeneous components. A global approach based on the free surface energy of a thermodynamic system containing the droplet and solid surface shows the static contact angle as a function of local surface chemistry and local wetting state at the contact line. A local approach, in which only local forces acting on the contact line are considered, results in the same equation. The fact that the local approach agrees with the global approach further demonstrates the static contact angle as a local wetting parameter. Additionally, the study also suggests that the wetting described by the Wenzel and Cassie equations is also the local wetting of the contact line rather than the global wetting of the droplet.

  5. A general model for preload calculation and stiffness analysis for combined angular contact ball bearings

    Science.gov (United States)

    Zhang, Jinhua; Fang, Bin; Hong, Jun; Wan, Shaoke; Zhu, Yongsheng

    2017-12-01

    The combined angular contact ball bearings are widely used in automatic, aerospace and machine tools, but few researches on the combined angular contact ball bearings have been reported. It is shown that the preload and stiffness of combined bearings are mutual influenced rather than simply the superposition of multiple single bearing, therefore the characteristic calculation of combined bearings achieved by coupling the load and deformation analysis of a single bearing. In this paper, based on the Jones quasi-static model and stiffness analytical model, a new iterative algorithm and model are proposed for the calculation of combined bearings preload and stiffness, and the dynamic effects include centrifugal force and gyroscopic moment have to be considered. It is demonstrated that the new method has general applicability, the preload factors of combined bearings are calculated according to the different design preloads, and the static and dynamic stiffness for various arrangements of combined bearings are comparatively studied and analyzed, and the influences of the design preload magnitude, axial load and rotating speed are discussed in detail. Besides, the change rule of dynamic contact angles of combined bearings with respect to the rotating speed is also discussed. The results show that bearing arrangement modes, rotating speed and design preload magnitude have a significant influence on the preload and stiffness of combined bearings. The proposed formulation provides a useful tool in dynamic analysis of the complex bearing-rotor system.

  6. The effects of the modulus of the lens material on intraocular pressure measurement through soft contact lenses.

    Science.gov (United States)

    Boyraz, S; Güngör, I

    2013-09-01

    To investigate the effects of the modulus of the lens material on the intraocular pressure measurement using the Tono-Pen XL applanation tonometer through soft contact lenses. Thirty eyes of 15 patients with myopia were evaluated. Intraocular pressure (IOP) measurements were performed using Tono-Pen XL directly over cornea, and subsequently through three soft contact lenses made up of different lens materials. All were -3.00 diopter soft contact lenses: lotrafilcon A with a low water content (24%) and high modulus (1.4 MPa) (CL-I), balafilcon A with a moderate water content (36%) and moderate modulus (1.1 MPa) (CL-II), and vifilcon A with a moderate water content (55%) and low modulus (0.79 MPa) (CL-III). IOP measurements through contact lenses were compared with each other, and with direct corneal measurements. The mean age of the patients (11 males and 4 females) was 26.86±5.62 years. All measurements obtained through CLs were significantly higher than the direct corneal measurements. The measurements through CLs differed by 4.61±0.54 mmHg (P=0,001), 2.9±0.46 mmHg (P=0.001), and 1.94±0.51 mmHg (P=0,003) for CL-I, CL-II and CL-III, respectively. In the paired comparisons of measurements through CLs, all comparisons were significant except the comparison of measurements through CL-II and CL-III (P=0.128). IOP measurements through silicone-hydrogel contact lenses with a high modulus and low water content were higher compared to the other contact lenses. While measuring IOP through CLs, the clinicians should consider the effect of the lens material and the features of the device used.

  7. Analysis of pipe stress using CAESAR II code

    International Nuclear Information System (INIS)

    Sitandung, Y.B.; Bandriyana, B.

    2002-01-01

    Analysis of this piping stress with the purpose of knowing stress distribution piping system in order to determine pipe supports configuration. As an example of analysis, Gas Exchanger to Warm Separator Line was chosen with, input data was firstly prepared in a document, i.e. piping analysis specification that its content named as pipe characteristics, material properties, operation conditions, guide equipment's and so on. Analysis result such as stress, load, displacement and the use support type were verified based on requirements in the code, standard, and regularities were suitable with piping system condition analyzed. As the proof that piping system is in safety condition, it can be indicated from analysis results (actual loads) which still under allowable load. From the analysis steps that have been done CAESAR II code fulfill requirements to be used as a tool of piping stress analysis as well as nuclear and non nuclear installation piping system

  8. Contact allergy to ingredients of topical medications : results of the European Surveillance System on Contact Allergies (ESSCA), 2009-2012

    NARCIS (Netherlands)

    Uter, Wolfgang; Spiewak, Radoslaw; Cooper, Susan M.; Wilkinson, Mark; Sanchez Perez, Javier; Schnuch, Axel; Schuttelaar, Marie-Louise

    2016-01-01

    PurposeThe aim of this study was to give an overview of the prevalence of contact allergy to active ingredients and excipients of topical medications across Europe. MethodsRetrospective analysis of data collected by the European Surveillance System on Contact Allergies () with substances applied to

  9. Pair housing for female longtailed and rhesus macaques in the laboratory: behavior in protected contact versus full contact.

    Science.gov (United States)

    Baker, Kate C; Crockett, Carolyn M; Lee, Grace H; Oettinger, Brooke C; Schoof, Valérie; Thom, Jinhee P

    2012-01-01

    Pair housing for caged macaques in the laboratory generally allows unrestricted tactile contact but, less commonly, may involve limited contact via grooming-contact bars or perforated panels. The purpose of using this protected contact housing, which prevents entry into pair-mates' cages, typically is to accommodate research and management requirements. The study used behavioral data collected on 12 pairs of female longtailed macaques (Macaca fascicularis) at the Washington National Primate Research Center and 7 pairs of female rhesus macaques (Macaca mulatta) housed at the Tulane National Primate Research Center to assess the relative benefits of protected versus full protected contact. The study collected data in stable pairs housed first in protected contact followed by full contact. Species combined, the study found the presence of the panel was associated with lower levels of social grooming and higher levels of self-grooming, abnormal behavior, and tension-related behavior. Within species, only the protected- versus full-contact contrasts for abnormal and tension were statistically significant-and only for rhesus macaques. Results suggest that for female rhesus macaques, potential disadvantages or inconveniences of full contact should be balanced against the improved behavioral profile in comparison to protected contact. The use of protected contact among female longtailed macaques does not appear to require the same cost-benefit analysis. Copyright © Taylor & Francis Group, LLC

  10. Integrating water exclusion theory into βcontacts to predict binding free energy changes and binding hot spots

    Science.gov (United States)

    2014-01-01

    Background Binding free energy and binding hot spots at protein-protein interfaces are two important research areas for understanding protein interactions. Computational methods have been developed previously for accurate prediction of binding free energy change upon mutation for interfacial residues. However, a large number of interrupted and unimportant atomic contacts are used in the training phase which caused accuracy loss. Results This work proposes a new method, βACV ASA , to predict the change of binding free energy after alanine mutations. βACV ASA integrates accessible surface area (ASA) and our newly defined β contacts together into an atomic contact vector (ACV). A β contact between two atoms is a direct contact without being interrupted by any other atom between them. A β contact’s potential contribution to protein binding is also supposed to be inversely proportional to its ASA to follow the water exclusion hypothesis of binding hot spots. Tested on a dataset of 396 alanine mutations, our method is found to be superior in classification performance to many other methods, including Robetta, FoldX, HotPOINT, an ACV method of β contacts without ASA integration, and ACV ASA methods (similar to βACV ASA but based on distance-cutoff contacts). Based on our data analysis and results, we can draw conclusions that: (i) our method is powerful in the prediction of binding free energy change after alanine mutation; (ii) β contacts are better than distance-cutoff contacts for modeling the well-organized protein-binding interfaces; (iii) β contacts usually are only a small fraction number of the distance-based contacts; and (iv) water exclusion is a necessary condition for a residue to become a binding hot spot. Conclusions βACV ASA is designed using the advantages of both β contacts and water exclusion. It is an excellent tool to predict binding free energy changes and binding hot spots after alanine mutation. PMID:24568581

  11. The Analysis of Three-Body Contact Temperature under the Different Third Particle Size, Density, and Value of Friction

    Directory of Open Access Journals (Sweden)

    Horng-Wen Wu

    2017-10-01

    Full Text Available Recently, many studies have investigated the friction, wear, and temperature characteristics of the interface between two relative movements. Such analyses often set the coefficient of friction as a fixed value and are analyzed in cases of two-body contact; however, the interface is often a three-body contact and the coefficient of friction varies depending on the operating conditions. This is a significant error in the analysis of contact characteristics, therefore, in this study, the actual interface and the change of the coefficient of friction were analyzed based on three-body micro-contact theory where the contact temperature was also analyzed and the difference between the generally assumed values were compared. The results showed that under three-body contact, the coefficient of total friction increased with an increase in particle size; and at a different particle size and area density of particles, the surface contact temperature increased with the plasticity index and load increases, and the particle contact temperature increased with the increasing particle size. The surface temperature rise was mainly affected by the ratio of the average temperature between surface 1 and surface 2 to the multiplication between the 100th root of the area density of particles and the square root of the equivalent surface roughness (Ts1s2_ave*/ηa0.01σ0.5 and the ratio of the 10th root of the mean particle diameter to the 100th root of the equivalent surface roughness (xa0.1/σ0.001. Particle temperature was mainly affected by the ratio of the 10th root of the mean particle diameter to the 100th root of the equivalent surface roughness (xa0.1/σ0.001 and the area density of particles ηa. Our study indicated that when the contact of surface with surface and the contact of the particles with the surface, the resulting heat balance was assigned to the particles and the surface in a three-body contact situation. Under this contact behavior, it could avoid

  12. Dynamic torsional response analysis of mechanoluminescent paint and its application to non-contacting automotive torque transducers

    International Nuclear Information System (INIS)

    Kim, Gi-Woo; Kim, Ji-Sik

    2014-01-01

    This paper presents the result of a preliminary experimental study on the dynamic torsional response analysis of mechanoluminescent (ML) paint for potential development as a new type of non-contacting torque transducer. The torsional torque applied to a transmission shaft is measured by sensing the ML intensity emitting from an ML paint coating a transmission shaft. This study provides the fundamental knowledge for the development of new non-contacting torque sensing technology based on the ML intensity detection. The proposed measurement principle appears to offer potential applications in automotive torque measurement systems, even though the loading rate-dependent characteristics of the ML intensity needs to be examined further. (paper)

  13. Dynamic torsional response analysis of mechanoluminescent paint and its application to non-contacting automotive torque transducers

    Science.gov (United States)

    Kim, Gi-Woo; Kim, Ji-Sik

    2014-01-01

    This paper presents the result of a preliminary experimental study on the dynamic torsional response analysis of mechanoluminescent (ML) paint for potential development as a new type of non-contacting torque transducer. The torsional torque applied to a transmission shaft is measured by sensing the ML intensity emitting from an ML paint coating a transmission shaft. This study provides the fundamental knowledge for the development of new non-contacting torque sensing technology based on the ML intensity detection. The proposed measurement principle appears to offer potential applications in automotive torque measurement systems, even though the loading rate-dependent characteristics of the ML intensity needs to be examined further.

  14. Analysis of the material's expenditure of electric contacts by means of the isotopic method

    International Nuclear Information System (INIS)

    Farkash, K.

    1979-01-01

    To investigate lifetime of the weak-current and heavy-current contacts different radioisotopic methods have been developed. Advantages of the radioisotopic methods as compared with other methods of testing consists of the fact that due to their sensitivity they permit to determine low expense of material; permit to determine quantitatively expense of each element separately from the elements, composing the contacts alloy; by means of these methods it is possible to evaluate quantitatively topological distribution of the matter separated from the contacts into the environment; it is possible to determine morphological characteristics of the matter separated from the contact. During investigation of the lifetime of contacts there were determined: value of the expense of the material of contacts; composition of the expense of the material of contacts; composition of the matter separated from the contact; distribution of the separated matter depending on the electrical parameters and number of the closings of contact in the case of different compositions of contacts and in different conditions. Strength of the contacts' alloys related to the electrical load was investigated at the special stand [ru

  15. Occupational contact dermatitis in blue-collar workers

    DEFF Research Database (Denmark)

    Schwensen, Jakob F; Menné, Torkil; Veien, Niels K

    2014-01-01

    BACKGROUND: Blue-collar workers have a high risk of occupational contact dermatitis, but epidemiological studies are scarce. OBJECTIVES: To investigate allergic contact dermatitis in blue-collar workers with dermatitis registered by the Danish Contact Dermatitis Group. METHODS: A retrospective...... analysis of patch test data from 1471 blue-collar workers and 1471 matched controls tested between 2003 and 2012 was performed. A logistic regression was used to test for associations. RESULTS: The blue-collar workers often had occupational hand dermatitis (p dermatitis was less commonly......, and methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI). The following occupations were additionally identified as risk factors for contact sensitization to MCI/MI and MI, epoxy resins, and potassium dichromate, respectively: painting, construction work, and tile setting/terrazzo work. CONCLUSION: Contact allergy...

  16. Regression model, artificial neural network, and cost estimation for biosorption of Ni(II)-ions from aqueous solutions by Potamogeton pectinatus.

    Science.gov (United States)

    Fawzy, Manal; Nasr, Mahmoud; Adel, Samar; Helmi, Shacker

    2018-03-21

    This study investigated the application of Potamogeton pectinatus for Ni(II)-ions biosorption from aqueous solutions. FTIR spectra showed that the functional groups of -OH, C-H, -C = O, and -COO- could form an organometallic complex with Ni(II)-ions on the biomaterial surface. SEM/EDX analysis indicated that the voids on the biosorbent surface were blocked due to Ni(II)-ions uptake via an ion exchange mechanism. For Ni(II)-ions of 50 mg/L, the adsorption efficiency recorded 63.4% at pH: 5, biosorbent dosage: 10 g/L, and particle-diameter: 0.125-0.25 mm within 180 minutes. A quadratic model depicted that the plot of removal efficiency against pH or contact time caused quadratic-linear concave up curves, whereas the curve of initial Ni(II)-ions was quadratic-linear convex down. Artificial neural network with a structure of 5 - 6 - 1 was able to predict the adsorption efficiency (R 2 : 0.967). The relative importance of inputs was: initial Ni(II)-ions > pH > contact time > biosorbent dosage > particle-size. Freundlich isotherm described well the adsorption mechanism (R 2 : 0.974), which indicated a multilayer adsorption onto energetically heterogeneous surfaces. The net cost of using P. pectinatus for the removal of Ni(II)-ions (4.25 ± 1.26 mg/L) from real industrial effluents within 30 minutes was 3.4 $USD/m 3 .

  17. Coordination compounds of cobalt(II), nickel(II), copper(II), and zinc(II) with pantothenic acid

    Energy Technology Data Exchange (ETDEWEB)

    Shabilalov, A.A.; Yunuskhodzhaev, A.N.; Khodzhaev, O.F.; Azizov, M.A.

    1986-11-01

    The compounds Ni(PANA - H)/sub 2/ x 4H/sub 2/O (PANA stands for pantothenic acid, and - H indicates a deprotonated ligand), Cu(PANA - H)/sub 2/ x 2H/sub 2/O, Zn(PANA - H)/sub 2/ x H/sub 2/O, Co(PANA - H)Cl x H/sub 2/O, and Ni(PANA - H)Cl x 3H/sub 2/O have been synthesized on the basis of pantothenic acid and Co(II), Ni(II), Cu(II), and Zn(II) salts in aqueous media. The compounds have been identified by elemental and x-ray diffraction analysis. Some physicochemical properties (solubility, melting point, molar conductivity) of the compounds obtained have been studied. The structure of the compounds isolated has been established on the basis of an analysis of their IR, ESR, and electronic spectra, as well as derivatograms.

  18. The synthesis of corncobs (zea mays) active charcoal and water hyacinth (eichornia crassipes) adsorbent to adsorb Pb(II) with it’s analysis using solid-phase spectrophotometry (sps)

    Science.gov (United States)

    Saputro, S.; Masykuri, M.; Mahardiani, L.; Kurniastuti, D.

    2018-03-01

    This research aim to examine the effect of the combination between corncobs and water hyacinth to adsorb lead (II), the most effective combination have determined by compared the ratio of corncobs adsorbent and water hyacinth to the increasing adsorption of the Pb(II), prove the effectiveness of the solid-phase spectrophotometry (sps) to determine the levels of Pb(II) as the result of the corncobs active charcoal adsorption and water hyacinth in the level of µg/L. The research method used is experimental method. The data collecting technique is carried out by several stages, which are carbonization using muffle furnace at a temperature of 350°C for 1.5 hours, activation of the corncobs charcoal and water hyacinth using HCl 1M and HCl 5M activator, contacting the adsorbent of corncobs active charcoal and water hyacinth with liquid waste simulation of Pb(II) using variation of corncobns and water hyacinth, 1:0; 0:1; 1:1; 2:1; 1:2, analysis of Pb(II) using an sps, characterization of corncobs active charcoal adsorbent and water hyacinth using FTIR. Research results show that the combined effect of activated charcoal corncobs and water hyacinth can increase the ability of the adsorbent to absorb Pb(II), the optimum adsorbent mass ratio of 1:1 with the absorption level of 90.33%, SPS is an effective method to analyze the decreasing level of Pb(II) as the adsorbtion result of the corncobs active charcoal and water hyacinth in the level of µg/L, with the limit of detection (LOD) of 0.06 µg/L.

  19. THE SPECTRUM AND TERM ANALYSIS OF V II

    International Nuclear Information System (INIS)

    Thorne, A. P.; Pickering, J. C.; Semeniuk, J. I.

    2013-01-01

    The spectrum and extended term analysis of V II are presented. Fourier transform spectrometry was used to record high resolution spectra of singly ionized vanadium in the region 1492-5800 Å (67020-17260 cm –1 ) with vanadium-neon and vanadium-argon hollow cathode lamps as sources. The wavenumber uncertainty for the center of gravity of the strongest lines is typically 0.002 cm –1 , an improvement of an order of magnitude over previous measurements. Most of the lines exhibit partly resolved hyperfine structure. The V II energy levels in the 1985 compilation of Sugar and Corliss have been confirmed and revised, with the exception of the high-lying 4f levels and eight of the lower levels. Thirty-nine of the additional eighty-five high levels published by Iglesias et al. have also been confirmed and revised, and three of their missing levels have been found. The energy uncertainty of the revised levels has been reduced by about an order of magnitude. In total, 176 even levels and 233 odd levels are presented. Wavenumbers and classifications are given for 1242 V II lines

  20. How pinning and contact angle hysteresis govern quasi-static liquid drop transfer.

    Science.gov (United States)

    Chen, H; Tang, T; Zhao, H; Law, K-Y; Amirfazli, A

    2016-02-21

    This paper presents both experimental and numerical simulations of liquid transfer between two solid surfaces with contact angle hysteresis (CAH). Systematic studies on the role of the advancing contact angle (θa), receding contact angle (θr) and CAH in determining the transfer ratio (volume of the liquid transferred onto the acceptor surface over the total liquid volume) and the maximum adhesion force (Fmax) were performed. The transfer ratio was found to be governed by contact line pinning at the end of the transfer process caused by CAH of surfaces. A map based on θr of the two surfaces was generated to identify the three regimes for liquid transfer: (I) contact line pinning occurs only on the donor surface, (II) contact line pinning occurs on both surfaces, and (III) contact line pinning occurs only on the acceptor surface. With this map, an empirical equation is provided which is able to estimate the transfer ratio by only knowing θr of the two surfaces. The value of Fmax is found to be strongly influenced by the contact line pinning in the early stretching stage. For symmetric liquid bridges between two identical surfaces, Fmax may be determined only by θa, only by θr, or by both θa and θr, depending on the magnitude of the contact angles. For asymmetric bridges, Fmax is found to be affected by the period when contact lines are pinned on both surfaces.

  1. Analysis of the evolvement of contact wire wear irregularity in railway catenary based on historical data

    NARCIS (Netherlands)

    Wang, H.; Nunez Vicencio, Alfredo; Liu, Zhigang; Song, Yang; Duan, Fuchuan; Dollevoet, R.P.B.J.

    2017-01-01

    This paper studies the evolvement of the wear irregularity of contact wire using wire thickness data measured yearly from a section of railway catenary. The power spectral density and time–frequency representation based on the wavelet transform are employed for data analysis, with an emphasis on

  2. A primer for biomedical scientists on how to execute model II linear regression analysis.

    Science.gov (United States)

    Ludbrook, John

    2012-04-01

    1. There are two very different ways of executing linear regression analysis. One is Model I, when the x-values are fixed by the experimenter. The other is Model II, in which the x-values are free to vary and are subject to error. 2. I have received numerous complaints from biomedical scientists that they have great difficulty in executing Model II linear regression analysis. This may explain the results of a Google Scholar search, which showed that the authors of articles in journals of physiology, pharmacology and biochemistry rarely use Model II regression analysis. 3. I repeat my previous arguments in favour of using least products linear regression analysis for Model II regressions. I review three methods for executing ordinary least products (OLP) and weighted least products (WLP) regression analysis: (i) scientific calculator and/or computer spreadsheet; (ii) specific purpose computer programs; and (iii) general purpose computer programs. 4. Using a scientific calculator and/or computer spreadsheet, it is easy to obtain correct values for OLP slope and intercept, but the corresponding 95% confidence intervals (CI) are inaccurate. 5. Using specific purpose computer programs, the freeware computer program smatr gives the correct OLP regression coefficients and obtains 95% CI by bootstrapping. In addition, smatr can be used to compare the slopes of OLP lines. 6. When using general purpose computer programs, I recommend the commercial programs systat and Statistica for those who regularly undertake linear regression analysis and I give step-by-step instructions in the Supplementary Information as to how to use loss functions. © 2011 The Author. Clinical and Experimental Pharmacology and Physiology. © 2011 Blackwell Publishing Asia Pty Ltd.

  3. Combination of rice husk and coconut shell activated adsorbent to adsorb Pb(II) ionic metal and it’s analysis using solid-phase spectrophotometry (sps)

    Science.gov (United States)

    Rohmah, D. N.; Saputro, S.; Masykuri, M.; Mahardiani, L.

    2018-03-01

    The purpose of this research was to know the effect and determine the mass comparation which most effective combination between rice husk and coconut shell activated adsorbent to adsorb Pb (II) ion using SPS method. This research used experimental method. Technique to collecting this datas of this research is carried out by several stages, which are: (1) carbonization of rice husk and coconut shell adsorbent using muffle furnace at a temperature of 350°C for an hour; (2) activation of the rice husk and coconut shell adsorbent using NaOH 1N and ZnCl2 15% activator; (3) contacting the adsorbent of rice husk and coconut shell activated adsorbent with liquid waste simulation of Pb(II) using variation comparison of rice husk and coconut shell, 1:0; 0:1; 1:1; 2:1; 1:2; (4) analysis of Pb(II) using Solid-Phase Spectrophotometry (SPS); (5) characterization of combination rice husk and coconut shell activated adsorbent using FTIR. The result of this research show that the combined effect of combination rice husk and coconut shell activated adsorbent can increase the ability of the adsorbent to absorb Pb(II) ion then the optimum adsorbent mass ratio required for absorbing 20 mL of Pb(II) ion with a concentration of 49.99 µg/L is a ratio of 2:1 with the absorption level of 97,06%Solid-Phase Spectrophotometry (SPS) is an effective method in the level of µg/L, be marked with the Limit of Detection (LOD) of 0.03 µg/L.

  4. Synthesis and characterization of heterobimetallic complexes of the type [Cu(pn2][MCl4] where M = Co(II, Ni(II, Cu(II, Zn(II, Cd(II, and Hg(II

    Directory of Open Access Journals (Sweden)

    Seema Yadav

    2016-11-01

    Full Text Available A series of new bimetallic transition metal complexes of the type [Cu(pn2] [MCl4] have been synthesized (where M = Co(II, Ni(II, Cu(II, Zn(II, Cd(II and Hg(II, pn = 1,3-diaminopropane and characterized by elemental analysis, molar conductance, TGA, IR and electronic spectra. All the compounds are 1:1 electrolyte in DMF. The Cu(II ion is square-planar while metal ions in the anionic moiety acquire their usual tetrahedral arrangement. On the basis of these studies it is concluded that anionic moiety is electrically stabilized by its cationic counterpart.

  5. Experimental quantification of contact forces with impact, friction and uncertainty analysis

    DEFF Research Database (Denmark)

    Lahriri, Said; Santos, Ilmar

    2013-01-01

    and whirl motions in rotor-stator contact investigations. Dry friction coefficient is therefore estimated using two different experimental setups: (a) standard pin-on-disk tests and (b) rotor impact test rig fully instrumented. The findings in both setups indicate that the dry friction coefficient for brass......During rotor-stator contact dry friction plays a significant role in terms of reversing the rotor precession. The frictional force causes an increase in the rotor's tangential velocity in the direction opposite to that of the angular velocity. This effect is crucial for defining ranges of dry whip......-aluminum configuration significantly varies in a range of 0.16-0.83. The rotor enters a full annular contact mode shortly after two impacts with a contact duration of approximately 0.004 s at each location. It is experimentally demonstrated that the friction force is not present when the rotor enters a full annular...

  6. Surface analysis of CdTe after various pre-contact treatments

    Energy Technology Data Exchange (ETDEWEB)

    Waters, D.M. [Univ. of California, Santa Cruz, CA (United States). Dept. of Physics; Niles, D.; Gessert, T.A.; Albin, D.; Rose, D.H.; Sheldon, P. [National Renewable Energy Lab., Golden, CO (United States)

    1998-09-01

    The authors present surface analysis of close-spaced sublimated (CSS) CdTe after various pre-contact treatments. Methods include Auger electron spectroscopy (AES), x-ray photoelectron spectroscopy (XPS), and grazing-incidence x-ray diffraction (GI-XRD). XPS and GI-XRD analyses of the surface residue left by the solution-based CdCl{sub 2} treatment do not indicate the presence of a significant amount of CdCl{sub 2}. In addition, the solubility properties and relatively high thermal stability of the residue suggest the presence of the oxychloride Cd{sub 3}Cl{sub 2}O{sub 2} rather than CdCl{sub 2} as the major chlorine-containing component. Of the methods tested for their effectiveness in removing the residue, only HNO{sub 3} etches removed all detectable traces of chlorine from the surface.

  7. Immobilization of (dd)heteronuclear hexacyanoferrates(II) in a gelatin matrix

    International Nuclear Information System (INIS)

    Mikhajlov, O.V.

    2008-01-01

    Data pertinent to potentiality of preparing salts of (dd)heteronuclear hexacyanoferrates(II) with(M 1 ) II and (M 2 ) II (M 1 , M 2 = Mn, Co, Ni, Cu, Zn, Cd) as a result of contact between M 1 2 [Fe(CN) 6 ] immobilized in a gelatin matrix and aqueous solutions of metal chlorides have been systematized and summarized. The decisive role of the gelatin matrix, performing the function of an organizing system in formation of (dd)heteronuclear hexacyanoferrates(II) of metals, has been pointed out [ru

  8. Modeling and analysis of periodic orbits around a contact binary asteroid

    NARCIS (Netherlands)

    Feng, J.; Noomen, R.; Visser, P.N.A.M.; Yuan, J.

    2015-01-01

    The existence and characteristics of periodic orbits (POs) in the vicinity of a contact binary asteroid are investigated with an averaged spherical harmonics model. A contact binary asteroid consists of two components connected to each other, resulting in a highly bifurcated shape. Here, it is

  9. Contact compliance effects in the frictional response of bioinspired fibrillar adhesives

    Science.gov (United States)

    Piccardo, Marco; Chateauminois, Antoine; Fretigny, Christian; Pugno, Nicola M.; Sitti, Metin

    2013-01-01

    The shear failure and friction mechanisms of bioinspired adhesives consisting of elastomer arrays of microfibres terminated by mushroom-shaped tips are investigated in contact with a rigid lens. In order to reveal the interplay between the vertical and lateral loading directions, experiments are carried out using a custom friction set-up in which normal stiffness can be made either high or low when compared with the stiffness of the contact between the fibrillar adhesive and the lens. Using in situ contact imaging, the shear failure of the adhesive is found to involve two successive mechanisms: (i) cavitation and peeling at the contact interface between the mushroom-shaped fibre tip endings and the lens; and (ii) side re-adhesion of the fibre's stem to the lens. The extent of these mechanisms and their implications regarding static friction forces is found to depend on the crosstalk between the normal and lateral loading directions that can result in contact instabilities associated with fibre buckling. In addition, the effects of the viscoelastic behaviour of the polyurethane material on the rate dependence of the shear response of the adhesive are accounted for. PMID:23554349

  10. Adherens junction distribution mechanisms during cell-cell contact elongation in Drosophila.

    Directory of Open Access Journals (Sweden)

    Gabrielle Goldenberg

    Full Text Available During Drosophila gastrulation, amnioserosa (AS cells flatten and spread as an epithelial sheet. We used AS morphogenesis as a model to investigate how adherens junctions (AJs distribute along elongating cell-cell contacts in vivo. As the contacts elongated, total AJ protein levels increased along their length. However, genetically blocking this AJ addition indicated that it was not essential for maintaining AJ continuity. Implicating other remodeling mechanisms, AJ photobleaching revealed non-directional lateral mobility of AJs along the elongating contacts, as well as local AJ removal from the membranes. Actin stabilization with jasplakinolide reduced AJ redistribution, and live imaging of myosin II along elongating contacts revealed fragmented, expanding and contracting actomyosin networks, suggesting a mechanism for lateral AJ mobility. Actin stabilization also increased total AJ levels, suggesting an inhibition of AJ removal. Implicating AJ removal by endocytosis, clathrin endocytic machinery accumulated at AJs. However, dynamin disruption had no apparent effect on AJs, suggesting the involvement of redundant or dynamin-independent mechanisms. Overall, we propose that new synthesis, lateral diffusion, and endocytosis play overlapping roles to populate elongating cell-cell contacts with evenly distributed AJs in this in vivo system.

  11. A T1 and DTI fused 3D corpus callosum analysis in pre- vs. post-season contact sports players

    Science.gov (United States)

    Lao, Yi; Law, Meng; Shi, Jie; Gajawelli, Niharika; Haas, Lauren; Wang, Yalin; Leporé, Natasha

    2015-01-01

    Sports related traumatic brain injury (TBI) is a worldwide public health issue, and damage to the corpus callosum (CC) has been considered as an important indicator of TBI. However, contact sports players suffer repeated hits to the head during the course of a season even in the absence of diagnosed concussion, and less is known about their effect on callosal anatomy. In addition, T1-weighted and diffusion tensor brain magnetic resonance images (DTI) have been analyzed separately, but a joint analysis of both types of data may increase statistical power and give a more complete understanding of anatomical correlates of subclinical concussions in these athletes. Here, for the first time, we fuse T1 surface-based morphometry and a new DTI analysis on 3D surface representations of the CCs into a single statistical analysis on these subjects. Our new combined method successfully increases detection power in detecting differences between pre- vs. post-season contact sports players. Alterations are found in the ventral genu, isthmus, and splenium of CC. Our findings may inform future health assessments in contact sports players. The new method here is also the first truly multimodal diffusion and T1-weighted analysis of the CC, and may be useful to detect anatomical changes in the corpus callosum in other multimodal datasets.

  12. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis.

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Li, Yung-Hui; Wang, Wei; Tien, Chung-Hao

    2018-03-06

    In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL) pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR) was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme.

  13. Contact analysis and experimental investigation of a linear ultrasonic motor.

    Science.gov (United States)

    Lv, Qibao; Yao, Zhiyuan; Li, Xiang

    2017-11-01

    The effects of surface roughness are not considered in the traditional motor model which fails to reflect the actual contact mechanism between the stator and slider. An analytical model for calculating the tangential force of linear ultrasonic motor is proposed in this article. The presented model differs from the previous spring contact model, the asperities in contact between stator and slider are considered. The influences of preload and exciting voltage on tangential force in moving direction are analyzed. An experiment is performed to verify the feasibility of this proposed model by comparing the simulation results with the measured data. Moreover, the proposed model and spring model are compared. The results reveal that the proposed model is more accurate than spring model. The discussion is helpful for designing and modeling of linear ultrasonic motors. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Contact and contagion: Probability of transmission given contact varies with demographic state in bighorn sheep.

    Science.gov (United States)

    Manlove, Kezia R; Cassirer, E Frances; Plowright, Raina K; Cross, Paul C; Hudson, Peter J

    2017-07-01

    Understanding both contact and probability of transmission given contact are key to managing wildlife disease. However, wildlife disease research tends to focus on contact heterogeneity, in part because the probability of transmission given contact is notoriously difficult to measure. Here, we present a first step towards empirically investigating the probability of transmission given contact in free-ranging wildlife. We used measured contact networks to test whether bighorn sheep demographic states vary systematically in infectiousness or susceptibility to Mycoplasma ovipneumoniae, an agent responsible for bighorn sheep pneumonia. We built covariates using contact network metrics, demographic information and infection status, and used logistic regression to relate those covariates to lamb survival. The covariate set contained degree, a classic network metric describing node centrality, but also included covariates breaking the network metrics into subsets that differentiated between contacts with yearlings, ewes with lambs, and ewes without lambs, and animals with and without active infections. Yearlings, ewes with lambs, and ewes without lambs showed similar group membership patterns, but direct interactions involving touch occurred at a rate two orders of magnitude higher between lambs and reproductive ewes than between any classes of adults or yearlings, and one order of magnitude higher than direct interactions between multiple lambs. Although yearlings and non-reproductive bighorn ewes regularly carried M. ovipneumoniae, our models suggest that a contact with an infected reproductive ewe had approximately five times the odds of producing a lamb mortality event of an identical contact with an infected dry ewe or yearling. Consequently, management actions targeting infected animals might lead to unnecessary removal of young animals that carry pathogens but rarely transmit. This analysis demonstrates a simple logistic regression approach for testing a priori

  15. Spontaneous imbibition in fractal tortuous micro-nano pores considering dynamic contact angle and slip effect: phase portrait analysis and analytical solutions.

    Science.gov (United States)

    Li, Caoxiong; Shen, Yinghao; Ge, Hongkui; Zhang, Yanjun; Liu, Tao

    2018-03-02

    Shales have abundant micro-nano pores. Meanwhile, a considerable amount of fracturing liquid is imbibed spontaneously in the hydraulic fracturing process. The spontaneous imbibition in tortuous micro-nano pores is special to shale, and dynamic contact angle and slippage are two important characteristics. In this work, we mainly investigate spontaneous imbibition considering dynamic contact angle and slip effect in fractal tortuous capillaries. We introduce phase portrait analysis to analyse the dynamic state and stability of imbibition. Moreover, analytical solutions to the imbibition equation are derived under special situations, and the solutions are verified by published data. Finally, we discuss the influences of slip length, dynamic contact angle and gravity on spontaneous imbibition. The analysis shows that phase portrait is an ideal tool for analysing spontaneous imbibition because it can evaluate the process without solving the complex governing ordinary differential equations. Moreover, dynamic contact angle and slip effect play an important role in fluid imbibition in fractal tortuous capillaries. Neglecting slip effect in micro-nano pores apparently underestimates imbibition capability, and ignoring variations in contact angle causes inaccuracy in predicting imbibition speed at the initial stage of the process. Finally, gravity is one of the factors that control the stabilisation of the imbibition process.

  16. Cr(III,Mn(II,Fe(III,Co(II,Ni(II,Cu(II and Zn(II Complexes with Diisobutyldithiocarbamato Ligand

    Directory of Open Access Journals (Sweden)

    Mohammad Tarique

    2011-01-01

    Full Text Available The synthesis of sulphur and nitrogen containing dithiocarbamato ligand derived from diisobutylamine as well as its coordination compounds with 3d series transition metals is presented. These synthesized compounds were characterized on the basis of elemental analysis, conductometric measurements and IR spectral studies. The analytical data showed the stoichiometry 1:2 and 1:3 for the compounds of the types ML2 {M=Mn(II, Co(II, Ni(II, Cu(II and Zn(II} and M'L3{M'=Cr(III and Fe(III} respectively. The conductometric measurements proved the non-electrolytic behaviour of all the compounds. The bidentate nature of dithiocarbamato moiety was confirmed on the basis of IR spectral data.

  17. Mutation and biochemical analysis in carnitine palmitoyltransferase type II (CPT II) deficiency

    DEFF Research Database (Denmark)

    Olpin, S E; Afifi, A; Clark, S

    2003-01-01

    Carnitine palmitoyltransferase type II (CPT II) deficiency has three basic phenotypes, late-onset muscular (mild), infantile/juvenile hepatic (intermediate) and severe neonatal. We have measured fatty acid oxidation and CPT II activity and performed mutation studies in 24 symptomatic patients...

  18. Safety analysis report for the TRUPACT-II shipping package (condensed version). Volume 2, Rev. 14

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-10-01

    This appendix determines the effective G values for payload shipping categories of contact handled transuranic (CH-TRU) waste materials, based on the radiolytic G values for waste materials that are discussed in detail in Appendix 3.6.8 of the Safety Analysis Report for the TRUPACT-II Shipping Package. The effective G values take into account self-absorption of alpha decay energy inside particulate contamination and the fraction of energy absorbed by nongas-generating materials. As described in Appendix 3.6.8, an effective G value, G{sub eff}, is defined by: G{sub eff} - {Sigma}{sub M} (F{sub M} x G{sub M}) F{sub M}-fraction of energy absorbed by material maximum G value for a material where the sum is over all materials present inside a waste container. The G value itself is determined primarily by the chemical properties of the material and its temperature. The value of F is determined primarily by the size of the particles containing the radionuclides, the distribution of radioactivity on the various materials present inside the waste container, and the stopping distance of alpha particles in air, in the waste materials, or in the waste packaging materials.

  19. Safety analysis report for the TRUPACT-II shipping package (condensed version). Volume 2, Rev. 14

    International Nuclear Information System (INIS)

    1994-10-01

    This appendix determines the effective G values for payload shipping categories of contact handled transuranic (CH-TRU) waste materials, based on the radiolytic G values for waste materials that are discussed in detail in Appendix 3.6.8 of the Safety Analysis Report for the TRUPACT-II Shipping Package. The effective G values take into account self-absorption of alpha decay energy inside particulate contamination and the fraction of energy absorbed by nongas-generating materials. As described in Appendix 3.6.8, an effective G value, G eff , is defined by: G eff - Σ M (F M x G M ) F M -fraction of energy absorbed by material maximum G value for a material where the sum is over all materials present inside a waste container. The G value itself is determined primarily by the chemical properties of the material and its temperature. The value of F is determined primarily by the size of the particles containing the radionuclides, the distribution of radioactivity on the various materials present inside the waste container, and the stopping distance of alpha particles in air, in the waste materials, or in the waste packaging materials

  20. Synthesis, Characterization, and Biological Activity of Mn(II, Fe(II, Co(II, Ni(II, Cu(II, Zn(II, and Cd(II Complexes of N-Thiophenoyl-N′-Phenylthiocarbohydrazide

    Directory of Open Access Journals (Sweden)

    M. Yadav

    2013-01-01

    Full Text Available Mn(II, Fe(II, Co(II, Ni(II, Cu(II, Zn(II, and Cd(II complex of N-thiophenoyl -N′-phenylthiocarbohydrazide (H2 TPTH have been synthesized and characterized by elemental analysis, magnetic susceptibility measurements, infrared, NMR, electronic, and ESR spectral studies. The complexes were found to have compositions [Mn(H TPTH2], [Co(TPTH (H2O2], [Ni(TPTH (H2O2], [Cu(TPTH], [Zn(H TPTH], [Cd(H TPTH2], and [Fe(H TPTH2(EtOH]. The magnetic and electronic spectral studies suggest square planar geometry for [Cu(TPTH], tetrahedral geometry for [Zn(TPTH] and [Cd(H TPTH2], and octahedral geometry for rest of the complexes. The infrared spectral studies of the 1 : 1 deprotonated complexes suggest bonding through enolic oxygen, thiolato sulfur, and both the hydrazinic nitrogens. Thus, H2TPTH acts as a binegative tetradentate ligand. H2 TPTH and its metal complexes have been screened against several bacteria and fungi.

  1. Association between cancer and contact allergy: a linkage study

    DEFF Research Database (Denmark)

    Engkilde, Kaare; Thyssen, Jacob P; Menné, Torkil

    2011-01-01

    by logistic regression analysis. Results An inverse association between contact allergy and non-melanoma skin- and breast cancer, respectively, was identified in both sexes, and an inverse trend for brain cancer was found in women with contact allergy. Additionally, a positive association between contact...... and cancer, few have looked into the association between cancer and contact allergy, a type IV allergy. By linking two clinical databases, the authors investigate the possible association between contact allergy and cancer. Methods Record linkage of two different registers was performed: (1) a tertiary...

  2. DYNAMIC HYBRIDS UNDER SOLVENCY II: RISK ANALYSIS AND MODIFICATION POSSIBILITIES

    Directory of Open Access Journals (Sweden)

    Christian Maier

    2017-06-01

    Full Text Available In this study, we investigate the new and standardized European system of supervisory called Solvency II. In essence, asymmetric distribution of information between policyholder and insurer triggered this new regulation which aims at better protecting policyholders. Its three-pillar model is about to challenge both, insurers as well as policyholders. The first pillar includes quantitative aspects, the second pillar contains qualitative aspects and the third pillar comprises market transparency and reporting obligations. Underwriting risks, the default risk of a bank and market risks can be identified for the dynamic hybrid. Solvency II covers all these risks in the first pillar and insurers shall deposit sufficient risk-bearing capital. In our analysis, we first identify the dynamic hybrid specific risks under the Solvency II regime und then develop product modifications to reduce this risk.

  3. MRI-based analysis of patellofemoral cartilage contact, thickness, and alignment in extension, and during moderate and deep flexion.

    Science.gov (United States)

    Freedman, Benjamin R; Sheehan, Frances T; Lerner, Amy L

    2015-10-01

    Several factors are believed to contribute to patellofemoral joint function throughout knee flexion including patellofemoral (PF) kinematics, contact, and bone morphology. However, data evaluating the PF joint in this highly flexed state have been limited. Therefore, the purpose of this study was to evaluate patellofemoral contact and alignment in low (0°), moderate (60°), and deep (140°) knee flexion, and then correlate these parameters to each other, as well as to femoral morphology. Sagittal magnetic resonance images were acquired on 14 healthy female adult knees (RSRB approved) using a 1.5 T scanner with the knee in full extension, mid-flexion, and deep flexion. The patellofemoral cartilage contact area, lateral contact displacement (LCD), cartilage thickness, and lateral patellar displacement (LPD) throughout flexion were defined. Intra- and inter-rater repeatability measures were determined. Correlations between patellofemoral contact parameters, alignment, and sulcus morphology were calculated. Measurement repeatability ICCs ranged from 0.94 to 0.99. Patellofemoral cartilage contact area and thickness, LCD, and LPD were statistically different throughout all levels of flexion (ppatellofemoral joint throughout its range of motion. This study agrees with past studies that investigated patellofemoral measures at a single flexion angle, and provides new insights into the relationship between patellofemoral contact and alignment at multiple flexion angles. The study provides a detailed analysis of the patellofemoral joint in vivo, and demonstrates the feasibility of using standard clinical magnetic resonance imaging scanners to image the knee joint in deep flexion. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. An elastic-plastic contact model for line contact structures

    Science.gov (United States)

    Zhu, Haibin; Zhao, Yingtao; He, Zhifeng; Zhang, Ruinan; Ma, Shaopeng

    2018-06-01

    Although numerical simulation tools are now very powerful, the development of analytical models is very important for the prediction of the mechanical behaviour of line contact structures for deeply understanding contact problems and engineering applications. For the line contact structures widely used in the engineering field, few analytical models are available for predicting the mechanical behaviour when the structures deform plastically, as the classic Hertz's theory would be invalid. Thus, the present study proposed an elastic-plastic model for line contact structures based on the understanding of the yield mechanism. A mathematical expression describing the global relationship between load history and contact width evolution of line contact structures was obtained. The proposed model was verified through an actual line contact test and a corresponding numerical simulation. The results confirmed that this model can be used to accurately predict the elastic-plastic mechanical behaviour of a line contact structure.

  5. EXOSAT and IUE observations of contact binaries

    International Nuclear Information System (INIS)

    Vilhu, O.; Heise, J.; Laboratorium voor Ruimteonderzoek, Utrecht, Netherlands)

    1986-01-01

    EXOSAT observations are reported of the contact binaries W UMa, VW Cep, 44t Boo, XY Leo, and V566 Oph and the detached short-period RS CVn stars ER Vul and HD 209943. Complete X-ray light curves were obtained for W UMa, VW Cep and 44t Boo. Nearly simultaneous IUE observations of VW Cep provide important comparisons of the Mg II emission, the UV continuum, and the FES light curve, pointing to extra hot gas at phase 0.75. The observations indicate that contact binaries have highly structured (in temperature and geometry) and highly variable coronae, not preferentially connected with either of the component stars. The observed dips can be interpreted as due to cool absorbing clouds above localized X-ray emitting regions. For VW Cep, 44t Boo, and XY Leo there is evidence that the neck regions are sites for X-ray-emitting hot gas. 66 references

  6. Seroepidemiology of Toxoplasmosis among People Having Close Contact with Animals.

    Science.gov (United States)

    Brandon-Mong, Guo-Jie; Che Mat Seri, Nurul Asma Anati; Sharma, Reuben Sunil-Kumar; Andiappan, Hemah; Tan, Tian-Chye; Lim, Yvonne Ai-Lian; Nissapatorn, Veeranoot

    2015-01-01

    A cross-sectional study was conducted to determine the seroepidemiology of Toxoplasma infection and its risk association among people having close contact with animals. A total of 312 blood samples were collected from veterinary personnel (veterinarian, technicians, and students) and pet owners from veterinary clinics and hospitals in the area of Klang Valley, Malaysia. About 4 cc of blood samples drawn from agreed participants were processed for measurement of anti-Toxoplasma IgG and IgM antibodies as well as avidity test of Toxoplasma IgG by ELISA I, II, and III kits. Meanwhile, the demographic profiles and possible risk factors of these participants were also recorded in the standardized data collection sheets. Overall seroprevalence of toxoplasmosis was observed in 62 (19.9%) participants being 7 (18.4%) in veterinarians, 15 (33.3%) in veterinary technicians, 29 (14.9%) in veterinary students, and 11 (31.4%) in pet owners. Of 19.9% Toxoplasma seropositive samples, 18.3% was positive for IgG antibody, 1.0% for IgM antibody, and 0.6% for both IgG and IgM antibodies. Of three different IgG avidity ELISA kits, ELISA III showed high avidity in all five seropositive samples (IgM and IgG/IgM antibodies) indicating chronic Toxoplasma infection which is consistent with no evidence of clinical toxoplasmosis diagnosed during the time of this study. Univariate analysis showed that age group, gender, study population, gardening, task performance, and working duration were significantly associated with Toxoplasma seropositivity. Further analysis by multivariate analysis using logistic regression showed that age group of ≥30 years old (OR = 0.34, 95% CI = 0.18-0.63, p = 0.001) and working or study duration of >10 years having close contact with animals (OR = 5.07, 95% CI = 1.80-14.24, p = 0.002) were identified as significant risks for Toxoplasma infection. Based on the results obtained, a comprehensive Toxoplasma screening and health

  7. Equilibrium contact angle or the most-stable contact angle?

    Science.gov (United States)

    Montes Ruiz-Cabello, F J; Rodríguez-Valverde, M A; Cabrerizo-Vílchez, M A

    2014-04-01

    It is well-established that the equilibrium contact angle in a thermodynamic framework is an "unattainable" contact angle. Instead, the most-stable contact angle obtained from mechanical stimuli of the system is indeed experimentally accessible. Monitoring the susceptibility of a sessile drop to a mechanical stimulus enables to identify the most stable drop configuration within the practical range of contact angle hysteresis. Two different stimuli may be used with sessile drops: mechanical vibration and tilting. The most stable drop against vibration should reveal the changeless contact angle but against the gravity force, it should reveal the highest resistance to slide down. After the corresponding mechanical stimulus, once the excited drop configuration is examined, the focus will be on the contact angle of the initial drop configuration. This methodology needs to map significantly the static drop configurations with different stable contact angles. The most-stable contact angle, together with the advancing and receding contact angles, completes the description of physically realizable configurations of a solid-liquid system. Since the most-stable contact angle is energetically significant, it may be used in the Wenzel, Cassie or Cassie-Baxter equations accordingly or for the surface energy evaluation. © 2013 Elsevier B.V. All rights reserved.

  8. A unified approach to the analysis and design of elasto-plastic structures with mechanical contact

    Science.gov (United States)

    Bendsoe, Martin P.; Olhoff, Niels; Taylor, John E.

    1990-01-01

    With structural design in mind, a new unified variational model has been developed which represents the mechanics of deformation elasto-plasticity with unilateral contact conditions. For a design problem formulated as maximization of the load carrying capacity of a structure under certain constraints, the unified model allows for a simultaneous analysis and design synthesis for a whole range of mechanical behavior.

  9. Analysis of criticality using NJOY, AMPX-II and KENO-IV systems

    International Nuclear Information System (INIS)

    Ferreira, C.R.; Santos, A. dos

    1989-01-01

    Trough a linking between the nuclear data code systems NJOY and AMPX-II, performed at Divisao de Fisica de Reatores-IPEN, it was made criticality analysis with the KENO-IV in two fast multiplying systems: JEZEBEL and GODIVA. The ENDF/B-IV and JENDL-2 was used throughout the analysis. It was found that the linking between NJOY and AMPX-II systems can be suitable for a benchmark calculation of neutron cross sections. The KENO-IV code cannot be applied in systems where the degree of anisotropic scattering is too high because this computer code treats scattering up to first order. The XSDRNPM results show that the results obtained with ENDF/B-IV are of better quality than those obtained with JENDL-2. (author) [pt

  10. Biosorption characteristic of Alcaligenes sp. BAPb.1 for removal of lead(II) from aqueous solution.

    Science.gov (United States)

    Jin, Yu; Yu, Sumei; Teng, Chunying; Song, Tao; Dong, Liying; Liang, Jinsong; Bai, Xin; Xu, Xiuhong; Qu, Juanjuan

    2017-06-01

    In this study, strain BAPb.1 was isolated from lead mining area and used as an adsorbent to remove lead(II) ions from aqueous solution. The physicochemical characteristics, heavy metal resistance and antibiotic sensitivity of strain BAPb.1 were investigated. Biosorption capacity was evaluated by batch biosorption experiments, and isothermal characteristics were discussed. Atomic force microscopy (AFM), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and Fourier transform infrared spectrometry (FTIR) were conducted to explore the mechanism for lead(II) adsorption. Based on morphological and physiological characteristics as well as the phylogenetic analysis of 16S rDNA sequences, strain BAPb.1 was identified as a member of the genus Alcaligenes. It exhibited high resistances to multiple heavy metals such as lead(II), copper(II), zinc(II), nickel(II) and chromium(VI), and to antibiotics such as kanamycin, ampicillin, streptomycin, chloramphenicol, and tetracycline. The optimum conditions for maximum biosorption rate of 85.2% and maximum capacity of 56.8 mg g -1 were found at pH of 5, adsorbent dosage of 1.5 g L -1 (dry weight), initial lead(II) concentration of 100 mg L -1 , and contact time of 30 min at 30 °C. Biosorption isotherms were well fitted with Langmuir isotherm model. Mechanism analysis reveals that the lead(II) ions may exchange with sodium and potassium ions, and the hydroxyl, carbonyl and phosphate groups on the cell surface can chelate the lead(II) ions, therefore, surface adsorption play significant role in the biosorption process.

  11. Kinetics, equilibrium, and thermodynamics investigation on the adsorption of lead(II) by coal-based activated carbon.

    Science.gov (United States)

    Yi, Zhengji; Yao, Jun; Zhu, Mijia; Chen, Huilun; Wang, Fei; Liu, Xing

    2016-01-01

    The goal of this research is to investigate the feasibility of using activated coal-based activated carbon (CBAC) to adsorb Pb(II) from aqueous solutions through batch tests. Effects of contact time, pH, temperature and initial Pb(II) concentration on the Pb(II) adsorption were examined. The Pb(II) adsorption is strongly dependent on pH, but insensitive to temperature. The best pH for Pb(II) removal is in the range of 5.0-5.5 with more than 90 % of Pb(II) removed. The equilibrium time was found to be 60 min and the adsorption data followed the pseudo-second-order kinetics. Isotherm data followed Langmuir isotherm model with a maximum adsorption capacity of 162.33 mg/g. The adsorption was exothermic and spontaneous in nature. The Fourier transform infrared spectroscopy and scanning electron microscopy analysis suggested that CBAC possessed a porous structure and was rich in carboxyl and hydroxyl groups on its surface, which might play a major role in Pb(II) adsorption. These findings indicated that CBAC has great potential as an alternative adsorbent for Pb(II) removal.

  12. Establishing an upper bound on contact resistivity of ohmic contacts to n-GaN nanowires

    International Nuclear Information System (INIS)

    Blanchard, Paul; Bertness, Kris A; Harvey, Todd; Sanford, Norman

    2014-01-01

    Contact resistivity ρ c is an important figure of merit in evaluating and improving the performance of electronic and optoelectronic devices. Due to the small size, unique morphology, and uncertain transport properties of semiconductor nanowires (NWs), measuring ρ c of contacts to NWs can be particularly challenging. In this work, Si-doped n-GaN NWs were grown by molecular beam epitaxy. Four-contact structures with 20 nm Ti/200 nm Al contacts were fabricated on individual NWs by photolithography, and the contacts were annealed to achieve ohmic behavior. Two-point resistances R 23  and four-point collinear resistances R 23collinear  were measured between the middle two contacts on each NW. These resistances were then modeled by taking into account the non-uniform distribution of current flow along the length of each contact. Contrary to the assumption that the resistance difference R 23 −R 23collinear  is equal to the total contact resistance R c , the distributed-current-flow contact model shows that R 23 −R 23collinear  ≪ R c when ρ c is sufficiently small. Indeed, the measured R 23 −R 23collinear  was so small in these devices that it was within the measurement uncertainty, meaning that it was not possible to directly calculate ρ c from these data. However, it was possible to calculate an upper bound on ρ c for each device based on the largest possible value of R 23 −R 23collinear . In addition, we took into account the large uncertainties in the NW transport properties by numerically maximizing ρ c with respect to the uncertainty range of each measured and assumed parameter in the contact model. The resulting upper limits on ρ c ranged from 4.2 × 10 −6  to 7.6 × 10 −6  Ω cm 2 , indicating that 20 nm Ti/200 nm Al is a good choice of ohmic contact for moderately-doped n-GaN NWs. The measurement and numerical analysis demonstrated here offer a general approach to modeling ohmic contact resistivity via NW four

  13. Adsorption of Cd(II) Metal Ion on Adsorbent beads from Biomass Saccharomycess cereviceae - Chitosan

    Science.gov (United States)

    Hasri; Mudasir

    2018-01-01

    The adsorbent beads that was preparation from Saccharomycess cereviceae culture strain FN CC 3012 and shrimp shells waste and its application for adsorption of Cd (II) metal ion has been studied. The study start with combination of Saccharomycess cereviceae biomass to chitosan (Sc-Chi), contact time, pH of solution and initial concentration of cations. Total Cd(II) metal ion adsorbed was calculated from the difference of metal ion concentration before and after adsorption by AAS. The results showed that optimum condition for adsorption of Cd(II) ions by Sc-Chi beads was achieved with solution pH of 4, contact time of 60 minutes and initial concentration adsorption 100mg/L. The hydroxyl (-OH) and amino (-NH2) functional groups were believed to be responsible for the adsorption of Cd(II) ions.

  14. The role of contact allergens in chronic idiopathic urticaria.

    Science.gov (United States)

    Hession, Meghan T; Scheinman, Pamela L

    2012-01-01

    The objective of this study was to determine whether contact allergens play a role in chronic idiopathic urticaria (CIU). We conducted a longitudinal prospective study of 23 patients with CIU. Patients were patch tested to a modified North American Contact Dermatitis Group standard, fragrance, and cosmetic series; other series were tested as warranted by relevant history and physical examination. Readings were performed at 48 and 72 hours. Patients were counseled to avoid proven contact allergens and were followed up 2 to 9 months after testing. Twenty-one of 23 patients were female. The mean age was 46 years. The mean duration of urticaria was 32 months. Of the 23 patients, 8 (35%) experienced improvement of their symptoms with allergen avoidance. Four (17%) experienced a complete remission, and 4 (17%) experienced partial improvement. Two of the complete responders challenged themselves to proven contact allergens and developed urticaria, which resolved upon allergen avoidance. The most common allergens were potassium dichromate (n = 9), nickel sulfate (n = 7), Myroxylon pereirae (n = 6), cobalt chloride, neomycin, p-phenylenediamine (n = 5); fragrance mix I, fragrance mix II (n = 4); cinnamic aldehyde (n = 3); and formaldehyde (n = 2). Patch testing may be helpful in the evaluation of CIU patients for whom previous workup has failed to reveal an etiology.

  15. Contact effects analyzed by a parameter extraction method based on a single bottom-gate/top-contact organic thin-film transistor

    Science.gov (United States)

    Takagaki, Shunsuke; Yamada, Hirofumi; Noda, Kei

    2018-03-01

    Contact effects in organic thin-film transistors (OTFTs) were examined by using our previously proposed parameter extraction method from the electrical characteristics of a single staggered-type device. Gate-voltage-dependent contact resistance and channel mobility in the linear regime were evaluated for bottom-gate/top-contact (BGTC) pentacene TFTs with active layers of different thicknesses, and for pentacene TFTs with contact-doped layers prepared by coevaporation of pentacene and tetrafluorotetracyanoquinodimethane (F4TCNQ). The extracted parameters suggested that the influence of the contact resistance becomes more prominent with the larger active-layer thickness, and that contact-doping experiments give rise to a drastic decrease in the contact resistance and a concurrent considerable improvement in the channel mobility. Additionally, the estimated energy distributions of trap density in the transistor channel probably reflect the trap filling with charge carriers injected into the channel regions. The analysis results in this study confirm the effectiveness of our proposed method, with which we can investigate contact effects and circumvent the influences of characteristic variations in OTFT fabrication.

  16. Biosorption of cadmium (II) and lead (II) from aqueous solutions using mushrooms: A comparative study

    Energy Technology Data Exchange (ETDEWEB)

    Vimala, R., E-mail: vimararagu@yahoo.co.in [School of Biotechnology, Chemical and Biomedical Engineering, VIT University, Vellore 632014, Tamil Nadu (India); Das, Nilanjana [School of Biotechnology, Chemical and Biomedical Engineering, VIT University, Vellore 632014, Tamil Nadu (India)

    2009-08-30

    Sorption capacity of oyster mushroom (Pleurotus platypus), button mushroom (Agaricus bisporus) and milky mushroom (Calocybe indica) were evaluated on biosorption of heavy metals, viz. cadmium (II) and lead (II) from aqueous solutions. The optimum sorption conditions were studied for each metal separately. The desired pH of the aqueous solution was found to be 6.0 for the removal of cadmium (II) and 5.0 for removal of lead (II) for all the mushrooms. The percent removal of both the metals was found to increase with the increase in biosorbent dosage and contact time. The fitness of the biosorption data for Langmuir and Freundlich adsorption models was investigated. It was found that biosorption of cadmium (II) and lead (II) ions onto the biomass of the three mushrooms were better suitable to Langmuir than Freundlich adsorption model. P. platypus showed the highest metal uptake potential for cadmium (q{sub max} 34.96 mg/g) whereas A. bisporus exhibited maximum potential for lead (q{sub max} 33.78 mg/g). Milky mushroom showed the lowest metal uptake capacity for both the metals. The present data confirms that mushrooms may be used as efficient biosorbent for the removal of cadmium (II) and lead (II) ions from aqueous solution.

  17. Removal of zinc (II) ion from aqueous solution by adsorption onto activated palm midrib bio-sorbent

    Science.gov (United States)

    Mulana, F.; Mariana; Muslim, A.; Mohibah, M.; Halim, K. H. Ku

    2018-03-01

    In this paper, palm midrib that was activated with mixed citric acid and tartaric acid as biosorbent was used to remove Zn (II) ion from aqueous solution. The aim of this research is to activate palm midrib by using a mixed citric acid and tartaric acid and to determine adsorption capacity of activated palm midrib biosorbent on Zn (II) ion uptake from aqueous solution. The effect of several parameters such as contact time, initial Zn (II) ion concentration and activator concentration on the degree of Zn (II) ion removal was examined. Atomic Absorption Spectroscopy method was performed to determine adsorbed amount of Zn (II) ion into activated biosorbent. The result showed that the adsorption process was relatively not so fast and equilibrium was reached after contact time of 120 min. The adsorption capacity of biosorbent reached a maximum when the concentration of mixed citric acid and tartaric acid was 1.6 M. The optimum adsorption capacity was 5.72 mg/g. The result was obtained on initial Zn (II) ion concentration of 80 ppm for 120-min contact time. Langmuir isotherm was found as the best fit for the equilibrium data indicating homogeneous adsorption of metal ions onto the biosorbent surface.

  18. Sliding contact fracture of dental ceramics: Principles and validation

    Science.gov (United States)

    Ren, Linlin; Zhang, Yu

    2014-01-01

    Ceramic prostheses are subject to sliding contact under normal and tangential loads. Accurate prediction of the onset of fracture at two contacting surfaces holds the key to greater long-term performance of these prostheses. In this study, building on stress analysis of Hertzian contact and considering fracture criteria for linear elastic materials, a constitutive fracture mechanics relation was developed to incorporate the critical fracture load with the contact geometry, coefficient of friction and material fracture toughness. Critical loads necessary to cause fracture under a sliding indenter were calculated from the constitutive equation, and compared with the loads predicted from elastic stress analysis in conjunction with measured critical load for frictionless normal contact—a semi-empirical approach. The major predictions of the models were calibrated with experimentally determined critical loads of current and future dental ceramics after contact with a rigid spherical slider. Experimental results conform with the trends predicted by the models. PMID:24632538

  19. Non-Contact Heart Rate and Blood Pressure Estimations from Video Analysis and Machine Learning Modelling Applied to Food Sensory Responses: A Case Study for Chocolate.

    Science.gov (United States)

    Gonzalez Viejo, Claudia; Fuentes, Sigfredo; Torrico, Damir D; Dunshea, Frank R

    2018-06-03

    Traditional methods to assess heart rate (HR) and blood pressure (BP) are intrusive and can affect results in sensory analysis of food as participants are aware of the sensors. This paper aims to validate a non-contact method to measure HR using the photoplethysmography (PPG) technique and to develop models to predict the real HR and BP based on raw video analysis (RVA) with an example application in chocolate consumption using machine learning (ML). The RVA used a computer vision algorithm based on luminosity changes on the different RGB color channels using three face-regions (forehead and both cheeks). To validate the proposed method and ML models, a home oscillometric monitor and a finger sensor were used. Results showed high correlations with the G color channel (R² = 0.83). Two ML models were developed using three face-regions: (i) Model 1 to predict HR and BP using the RVA outputs with R = 0.85 and (ii) Model 2 based on time-series prediction with HR, magnitude and luminosity from RVA inputs to HR values every second with R = 0.97. An application for the sensory analysis of chocolate showed significant correlations between changes in HR and BP with chocolate hardness and purchase intention.

  20. Combination of the LEP II ffbar Results

    CERN Document Server

    Geweniger, C; Elsing, M; Goy, C; Holt, J; Liebig, W; Minard, M N; Renton, P B; Riemann, S; Sachs, K; Ward, P; Wynhoff, S

    2002-01-01

    Preliminary combinations of measurements of the 4 LEP collaborations of the process e+e-->ffbar at LEP-II are presented, using data from the full LEP-II data set where available. Cross-sections and forward-backward asymmetry measurements are combined for the full LEP-II data set. Combined differential cross-sections $\\frac{{\\rm d}\\sigma}{{\\rm d}\\cos\\theta}$ for electron-pairs, muon pair and tau-pair final states are presented. Measurements of the production of heavy flavours are combined. The combined results are interpreted in terms of contact interactions and the exchange Z' bosons and leptoquarks, and within models of low scale gravity in large extra dimensions.

  1. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis

    Science.gov (United States)

    Hsieh, Sheng-Hsun; Wang, Wei; Tien, Chung-Hao

    2018-01-01

    In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL) pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR) was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme. PMID:29509692

  2. A Novel Anti-Spoofing Solution for Iris Recognition Toward Cosmetic Contact Lens Attack Using Spectral ICA Analysis

    Directory of Open Access Journals (Sweden)

    Sheng-Hsun Hsieh

    2018-03-01

    Full Text Available In this study, we maneuvered a dual-band spectral imaging system to capture an iridal image from a cosmetic-contact-lens-wearing subject. By using the independent component analysis to separate individual spectral primitives, we successfully distinguished the natural iris texture from the cosmetic contact lens (CCL pattern, and restored the genuine iris patterns from the CCL-polluted image. Based on a database containing 200 test image pairs from 20 CCL-wearing subjects as the proof of concept, the recognition accuracy (False Rejection Rate: FRR was improved from FRR = 10.52% to FRR = 0.57% with the proposed ICA anti-spoofing scheme.

  3. Analysis of the role of PCNA-DNA contacts during clamp loading

    Directory of Open Access Journals (Sweden)

    Goedken Eric R

    2010-01-01

    Full Text Available Abstract Background Sliding clamps, such as Proliferating Cell Nuclear Antigen (PCNA in eukaryotes, are ring-shaped protein complexes that encircle DNA and enable highly processive DNA replication by serving as docking sites for DNA polymerases. In an ATP-dependent reaction, clamp loader complexes, such as the Replication Factor-C (RFC complex in eukaryotes, open the clamp and load it around primer-template DNA. Results We built a model of RFC bound to PCNA and DNA based on existing crystal structures of clamp loaders. This model suggests that DNA would enter the clamp at an angle during clamp loading, thereby interacting with positively charged residues in the center of PCNA. We show that simultaneous mutation of Lys 20, Lys 77, Arg 80, and Arg 149, which interact with DNA in the RFC-PCNA-DNA model, compromises the ability of yeast PCNA to stimulate the DNA-dependent ATPase activity of RFC when the DNA is long enough to extend through the clamp. Fluorescence anisotropy binding experiments show that the inability of the mutant clamp proteins to stimulate RFC ATPase activity is likely caused by reduction in the affinity of the RFC-PCNA complex for DNA. We obtained several crystal forms of yeast PCNA-DNA complexes, measuring X-ray diffraction data to 3.0 Å resolution for one such complex. The resulting electron density maps show that DNA is bound in a tilted orientation relative to PCNA, but makes different contacts than those implicated in clamp loading. Because of apparent partial disorder in the DNA, we restricted refinement of the DNA to a rigid body model. This result contrasts with previous analysis of a bacterial clamp bound to DNA, where the DNA was well resolved. Conclusion Mutational analysis of PCNA suggests that positively charged residues in the center of the clamp create a binding surface that makes contact with DNA. Disruption of this positive surface, which had not previously been implicated in clamp loading function, reduces RFC

  4. Allergic contact dermatitis: A comparison between atopic and non-atopic individuals

    International Nuclear Information System (INIS)

    Rani, Z.; Hussain, I.; Haroon, T.S.

    2002-01-01

    Objective: To determine the prevalence of ACD in atopics in comparison to non-atopics in our community. Design: Cross sectional study. Place and Duration of Study: Departments of Dermatology, King Edward Medical College/Mayo Hospital, Lahore, from May 1998 to July 1999. Subjects and Methods: Two hundred and fifty patients, 34 with past or present atopic dermatitis (Group I), 88 with personal or familial atopy (Group II) and 128 non-atopic with contact dermatitis (Group III) were subjected to patch testing with European standard series. The results were interpreted according to International Contact Dermatitis Research Group guidelines. Results: Positive reactions were seen in 50%, 70.4% and 67.8% of patients in the respective groups (p>0.05). Conclusion: Our results suggest that atopics are equally affected with contact dermatitis as compared with non-atopics and recalcitrant cases of atopic dermatitis should be patch tested to find out aggravating factors. (author)

  5. Reducing contact resistance in graphene devices through contact area patterning.

    Science.gov (United States)

    Smith, Joshua T; Franklin, Aaron D; Farmer, Damon B; Dimitrakopoulos, Christos D

    2013-04-23

    Performance of graphene electronics is limited by contact resistance associated with the metal-graphene (M-G) interface, where unique transport challenges arise as carriers are injected from a 3D metal into a 2D-graphene sheet. In this work, enhanced carrier injection is experimentally achieved in graphene devices by forming cuts in the graphene within the contact regions. These cuts are oriented normal to the channel and facilitate bonding between the contact metal and carbon atoms at the graphene cut edges, reproducibly maximizing "edge-contacted" injection. Despite the reduction in M-G contact area caused by these cuts, we find that a 32% reduction in contact resistance results in Cu-contacted, two-terminal devices, while a 22% reduction is achieved for top-gated graphene transistors with Pd contacts as compared to conventionally fabricated devices. The crucial role of contact annealing to facilitate this improvement is also elucidated. This simple approach provides a reliable and reproducible means of lowering contact resistance in graphene devices to bolster performance. Importantly, this enhancement requires no additional processing steps.

  6. Sesquiterpene lactone mix as a diagnostic tool for Asteraceae allergic contact dermatitis: chemical explanation for its poor performance and Sesquiterpene lactone mix II as a proposed improvement.

    Science.gov (United States)

    Jacob, Mathias; Brinkmann, Jürgen; Schmidt, Thomas J

    2012-05-01

    Two preparations are currently in use for the diagnosis of allergic contact dermatitis caused by Asteraceae: (i) Sesquiterpene lactone (SL) mix [three pure sesquiterpene lactones (STLs)], whose use has been questioned, owing to an insufficient rate of true-positive results; and (ii) Compositae mix, consisting of five Asteraceae extracts, which is problematic because of lack of standardization and questionable reproducibility. To analyse the reasons for the narrow sensitivity of SL mix from a chemoinformatic point of view, and to propose a solution by rational selection of alternative constituents for a new SL mix II covering a broader cohort of allergic patients. Structural and biological information on allergenic STLs was retrieved from databases and the literature, and molecular modelling and chemoinformatic computations were performed. An explanation for the insufficient hit rate of SL mix is that the three constituents possess extremely similar molecular structures/properties and do not represent well the structural diversity of allergenic STLs. STLs that are known as constituents of Compositae mix plants show much a wider diversity, which explains the higher positive rate. On the basis of their positions in chemical property space, a new collection of STLs that more evenly cover the overall structural diversity spectrum is proposed. SL mix II is likely to detect a larger number of patients sensitized to Asteraceae. © 2012 John Wiley & Sons A/S.

  7. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji [Dental Research Institute, School of Dentistry, Seoul National University, Seoul (Korea, Republic of)

    2015-03-15

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  8. Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

    International Nuclear Information System (INIS)

    Kang, Sung Won; Lee, Woo Jin; Choi, Soon Chul; Lee, Sam Sun; Heo, Min Suk; Huh, Kyung Hoe; Kim, Tae Il; Yi, Won Ji

    2015-01-01

    We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.

  9. Prioritized Contact Transport Stream

    Science.gov (United States)

    Hunt, Walter Lee, Jr. (Inventor)

    2015-01-01

    A detection process, contact recognition process, classification process, and identification process are applied to raw sensor data to produce an identified contact record set containing one or more identified contact records. A prioritization process is applied to the identified contact record set to assign a contact priority to each contact record in the identified contact record set. Data are removed from the contact records in the identified contact record set based on the contact priorities assigned to those contact records. A first contact stream is produced from the resulting contact records. The first contact stream is streamed in a contact transport stream. The contact transport stream may include and stream additional contact streams. The contact transport stream may be varied dynamically over time based on parameters such as available bandwidth, contact priority, presence/absence of contacts, system state, and configuration parameters.

  10. Performance of Spent Mushroom Farming Waste (SMFW) Activated Carbon for Ni (II) Removal

    Science.gov (United States)

    Desa, N. S. Md; Ghani, Z. Ab; Talib, S. Abdul; Tay, C. C.

    2016-07-01

    The feasibility of a low cost agricultural waste of spent mushroom farming waste (SMFW) activated carbon for Ni(II) removal was investigated. The batch adsorption experiments of adsorbent dosage, pH, contact time, metal concentration, and temperature were determined. The samples were shaken at 125 rpm, filtered and analyzed using ICP-OES. The fifty percent of Ni(II) removal was obtained at 0.63 g of adsorbent dosage, pH 5-6 (unadjusted), 60 min contact time, 50 mg/L Ni(II) concentration and 25 °C temperature. The evaluated SMFW activated carbon showed the highest performance on Ni(II) removal compared to commercial Amberlite IRC86 resin and zeolite NK3. The result indicated that SMFW activated carbon is a high potential cation exchange adsorbent and suitable for adsorption process for metal removal. The obtained results contribute toward application of developed SMFW activated carbon in industrial pilot study.

  11. Decomposition of Copper (II) Sulfate Pentahydrate: A Sequential Gravimetric Analysis.

    Science.gov (United States)

    Harris, Arlo D.; Kalbus, Lee H.

    1979-01-01

    Describes an improved experiment of the thermal dehydration of copper (II) sulfate pentahydrate. The improvements described here are control of the temperature environment and a quantitative study of the decomposition reaction to a thermally stable oxide. Data will suffice to show sequential gravimetric analysis. (Author/SA)

  12. Analyses of a steel containment vessel with an outer contact structure under severe internal overpressurization conditions

    International Nuclear Information System (INIS)

    Porter, V.L.

    1994-01-01

    Many Mark-I and Mark-II BWR plants are designed with a steel vessel as the primary containment. Typically, the steel containment vessel (SCV) is enclosed within a reinforced concrete shield building with only a small gap (74-90 mm) separating the two structures. This paper describes finite element analyses performed to evaluate the effects of contact and friction between a steel containment vessel and an outer contact structure when the containment vessel is subjected to large internal pressures. These computations were motivated by a joint program on containment integrity involving the Nuclear Power Engineering Corporation (NUPEC) of Japan, the US Nuclear Regulatory Commission (NRC), and Sandia National Laboratories for testing model containments. Under severe accident loading conditions, the steel containment vessel in a typical Mark-I or Mark-II plant may deform under internal pressurization such that it contacts the inner surface of a shield building wall. (Thermal expansion from increasing accident temperatures would also close the gap between the SCV and the shield building, but temperature effects are not considered in these analyses.) The amount and location of contact and the pressure at which it occurs all affect how the combined structure behaves. A preliminary finite element model has been developed to analyze a model of a typical steel containment vessel con-ling into contact with an outer structure. Both the steel containment vessel and the outer contact structure were modelled with axisymmetric shell finite elements. Of particular interest are the influence that the contact structure has on deformation and potential failure modes of the containment vessel. Furthermore, the coefficient of friction between the two structures was varied to study its effects on the behavior of the containment vessel and on the uplift loads transmitted to the contact structure. These analyses show that the material properties of an outer contact structure and the amount

  13. Guidelines for uncertainty analysis developed for the participants in the BIOMOVS II study

    International Nuclear Information System (INIS)

    Baeverstam, U.; Davis, P.; Garcia-Olivares, A.; Henrich, E.; Koch, J.

    1993-07-01

    This report has been produced to provide guidelines for uncertainty analysis for use by participants in the BIOMOVS II study. It is hoped that others with an interest in modelling contamination in the biosphere will also find it useful. The report has been prepared by members of the Uncertainty and Validation Working Group and has been reviewed by other BIOMOVS II participants. The opinions expressed are those of the authors and should not be taken to represent the views of the BIOMOVS II sponsors or other BIOMOVS Il participating organisations

  14. Guidelines for uncertainty analysis developed for the participants in the BIOMOVS II study

    Energy Technology Data Exchange (ETDEWEB)

    Baeverstam, U; Davis, P; Garcia-Olivares, A; Henrich, E; Koch, J

    1993-07-01

    This report has been produced to provide guidelines for uncertainty analysis for use by participants in the BIOMOVS II study. It is hoped that others with an interest in modelling contamination in the biosphere will also find it useful. The report has been prepared by members of the Uncertainty and Validation Working Group and has been reviewed by other BIOMOVS II participants. The opinions expressed are those of the authors and should not be taken to represent the views of the BIOMOVS II sponsors or other BIOMOVS Il participating organisations.

  15. Nickel(II) and copper(II) complexes of N,N-dialkyl-N‧-3-chlorobenzoylthiourea: Synthesis, characterization, crystal structures, Hirshfeld surfaces and antimicrobial activity

    Science.gov (United States)

    Binzet, Gun; Gumus, Ilkay; Dogen, Aylin; Flörke, Ulrich; Kulcu, Nevzat; Arslan, Hakan

    2018-06-01

    We synthesized four new N,N-dialkyl-N‧-3-chlorobenzoylthiourea ligands (Alkyl: Dimethyl, diethyl, di-n-propyl and di-n-butyl) and their metal complexes with copper and nickel atoms. The structure of all synthesized compounds was fully characterized by physicochemical, spectroscopic and single crystal X-ray diffraction analysis techniques. The physical, spectral and analytical data of the newly synthesized metal complexes have shown the formation of 1:2 (metal:ligand) ratio. The benzoylthiourea ligands coordinate with metal atoms through oxygen and sulphur atoms. The metal atoms are in slightly distorted square-planar coordination geometry in Ni(II) or Cu(II) complex. Two oxygen and two sulphur atoms are mutually cis to each other in Ni(II) or Cu(II) complex. The intermolecular contacts in the compounds, which are HL1 and HL3, were examined by Hirshfeld surfaces and fingerprint plots using the data obtained from X-ray single crystal diffraction measurement. Besides these, their antimicrobial activities against Gram-positive bacteria (Bacillus subtilis, Staphylococcus aureus, Streptococcus pyogenes and Enterococcus faecalis) and Gram-negative bacteria (Escherichia coli and Pseudomonas aeruginosa) and anti-yeast activity (Candida glabrata, Candida parapsilosis and Candida albicans) were investigated. This exhibited some promising results towards testing organism. Among all the compounds, Ni(L1)2 complex showed high activity against Bacillus subtilis with MIC values at 7.81 μg/mL.

  16. (II) metal ions using phosphonate-functionalized polymer

    Indian Academy of Sciences (India)

    The metal binding was examined by the energy dispersive spectroscopy and scanning electron microscopy for the adsorbed Sr(II). Batch adsorption studies were performed by varying three parameters, namely initial pH, adsorbentdose and the contact time. The reaction kinetics was determined by the Langmuir, Freundlich, ...

  17. Back-contacted BaSi

    NARCIS (Netherlands)

    Vismara, R.; Isabella, O.; Zeman, M.

    2017-01-01

    We present the optical investigation of a novel back-contacted architecture for solar cells based on a thin barium (di)silicide (BaSi2) absorber. First, through the analysis of absorption limits of different semiconducting materials, we show the potential of BaSi2 for

  18. A Numerical Simulation of Elastoplastic Contact Analysis of Compressor by Overspeeding

    Directory of Open Access Journals (Sweden)

    Aihua Liao

    2014-04-01

    Full Text Available This study analyzes the stress distribution of 3D elastoplastic contact problems by using the FE parametric quadratic programming (PQP method derived from a 3D FE model based on parametric variational principle (PVP. We numerically analyze a 24-blade compressor by combining centrifugal loading with interference-fit one. To accelerate computation, calculation is simplified by structural modeling via multisubstructuring, aiming to deal with FE-simulated computer aided design (CAD conveniently. We then analyze the relationships between the maximum residual stresses of the compressor posterior to prestressing and overspeed rpms, and we also study the distribution and magnitude of the contact stresses of the compressor in working conditions after overspeed prestressing. Moreover, we thoroughly discuss the distribution and magnitude of the contact stresses of shaft-shaft sleeve-impeller in working conditions. Relative displacement can be prevented and contact stress can be kept uniform due to the nonuniform initial amount of interference in overspeed prestressing. This paper summarizes the FEM simulation results and provides reference data for improving the design and processing of compressor impellers, indicating that overspeed is indispensable in manufacture.

  19. Language Contact.

    Science.gov (United States)

    Nelde, Peter Hans

    1995-01-01

    Examines the phenomenon of language contact and recent trends in linguistic contact research, which focuses on language use, language users, and language spheres. Also discusses the role of linguistic and cultural conflicts in language contact situations. (13 references) (MDM)

  20. Experimental programme and analysis, ZENITH II, Core 4

    Energy Technology Data Exchange (ETDEWEB)

    Ingram, G.; Sanders, J. E.; Sherwin, J.

    1974-10-15

    The Phase 3 program of reactor physics experiments on the HTR (or Mk 3 GCR) lattices continued during the first half of 1974 with a study of a series of critical builds in Zenith II aimed at testing predictions of shut-down margins in the local criticality-situations arising during power reactor refueling. The paper describes the experimental program and the subsequent theoretical analysis using methods developed in the United Kingdom for calculating low-enriched uranium HTR fuel systems. The importance of improving the accuracy of predictions of shut-down margins arises from the basic requirement that the core in its most reactive condition and with a specified number of absorbers removed from the array must remain sub-critical with a margin adequate to cover the total uncertainty of +/- 1 Nile (that is, 1 % delta-k). The major uncertainty is that in modelling the complex fuel/absorber configuration, and this is the aspect essentially covered in the Zenith II Core 4 studies.

  1. Visual method for detecting critical damage in railway contact strips

    Science.gov (United States)

    Judek, S.; Skibicki, J.

    2018-05-01

    Ensuring an uninterrupted supply of power in the electric traction is vital for the safety of this important transport system. For this purpose, monitoring and diagnostics of the technical condition of the vehicle’s power supply elements are becoming increasingly common. This paper presents a new visual method for detecting contact strip damage, based on measurement and analysis of the movement of the overhead contact line (OCL) wire. A measurement system configuration with a 2D camera was proposed. The experimental method has shown that contact strips damage can be detected by transverse displacement signal analysis. It has been proven that the velocity signal numerically established on that basis has a comparable level in the case of identical damage, regardless of its location on the surface of the contact strip. The proposed method belongs to the group of contact-less measurements, so it does not require interference with the structure of the catenary network nor the mounting of sensors in its vicinity. Measurement of displacements of the contact wire in 2D space makes it possible to combine the functions of existing diagnostic stands assessing the correctness of the mean contact force control adjustment of the current collector with the elements of the contact strip diagnostics, which involves detecting their damage which may result in overhead contact line rupture.

  2. Lithium and boron analysis by LA-ICP-MS results from a bowed PWR rod with contact

    Directory of Open Access Journals (Sweden)

    Puranen Anders

    2017-01-01

    Full Text Available A previously published investigation of an irradiated fuel rod from the Ringhals 2 PWR, which was bowed to contact with an adjacent rod, identified a significant but highly localised thinning of the clad wall and increased corrosion. Rod fretting was deemed unlikely due to the adhering oxide covering the surfaces. Local overheating in itself was also deemed insufficient to account for the accelerated corrosion. Instead, an enhanced concentration of lithium due to conditions of local boiling was hypothesised to explain the accelerated corrosion. Studsvik has developed a hot cell coupled LA-ICP-MS (Laser Ablation Inductively Coupled Plasma Mass Spectrometer equipment that enables a flexible means of isotopic analysis of irradiated fuel and other highly active surfaces. In this work, the equipment was used to investigate the distribution of lithium (7Li and boron (11B in the outer oxide at the bow contact area. Depth profiling in the clad oxide at the opposite side of the rod to the point of contact, which is considered to have experienced normal operating conditions and which has a typical oxide thickness, evidenced levels of ∼10–20 ppm 7Li and a 11B content reaching hundreds of ppm in the outer parts of the oxide, largely in agreement with the expected range of Li and B clad oxide concentrations from previous studies. In the contact area, the 11B content was similar to the reference condition at the opposite side. The 7Li content in the outermost oxide closest to the contact was, however, found to be strongly elevated, reaching several hundred ppm. The considerable and highly localised increase in lithium content at the area of enhanced corrosion thus offers strong evidence for a case of lithium induced breakaway corrosion during power operation, when rod-to-rod contact and high enough surface heat flux results in a very local increase in lithium concentration.

  3. Contact mechanics of articular cartilage layers asymptotic models

    CERN Document Server

    Argatov, Ivan

    2015-01-01

    This book presents a comprehensive and unifying approach to articular contact mechanics with an emphasis on frictionless contact interaction of thin cartilage layers. The first part of the book (Chapters 1–4) reviews the results of asymptotic analysis of the deformational behavior of thin elastic and viscoelastic layers. A comprehensive review of the literature is combined with the authors’ original contributions. The compressible and incompressible cases are treated separately with a focus on exact solutions for asymptotic models of frictionless contact for thin transversely isotropic layers bonded to rigid substrates shaped like elliptic paraboloids. The second part (Chapters 5, 6, and 7) deals with the non-axisymmetric contact of thin transversely isotropic biphasic layers and presents the asymptotic modelling methodology for tibio-femoral contact. The third part of the book consists of Chapter 8, which covers contact problems for thin bonded inhomogeneous transversely isotropic elastic layers, and Cha...

  4. Synthesis, spectral characterization thermal stability, antimicrobial studies and biodegradation of starch–thiourea based biodegradable polymeric ligand and its coordination complexes with [Mn(II), Co(II), Ni(II), Cu(II), and Zn(II)] metals

    OpenAIRE

    Nahid Nishat; Ashraf Malik

    2016-01-01

    A biodegradable polymer was synthesized by the modification reaction of polymeric starch with thiourea which is further modified by transition metals, Mn(II), Co(II), Ni(II), Cu(II) and Zn(II). All the polymeric compounds were characterized by (FT-IR) spectroscopy, 1H NMR spectroscopy, 13C NMR spectroscopy, UV–visible spectra, magnetic moment measurements, thermogravimetric analysis (TGA) and antibacterial activities. Polymer complexes of Mn(II), Co(II) and Ni(II) show octahedral geometry, wh...

  5. Effect of Temperature and Vibration on Electrical Connectors with Different Number of Contact Cores

    Directory of Open Access Journals (Sweden)

    Song W. L.

    2016-01-01

    Full Text Available In this paper, we presented the results from three related analysis performed by adopting the failure models, which provided an explanation of performance influencing factors caused by different number of contact cores, for the purpose of measuring the temperature change and deformation value, which were the factors causing contact failure. The failures were localized in contact parts of the connectors. Performed investigations included thermal analysis, modal analysis, harmonic response analysis and contact failure analysis. From the results of these simulations, related temperature and vibration analysis nephograms were got respectively. And the correctness of results of thermal analysis was verified by Fourier law. The research results of this paper provide a reference for thermal analysis and vibration analysis of electrical connectors, which is important for ensuring the reliability and safety of electrical connectors.

  6. Infrared and Raman spectroscopic study of ion pairing of strontium(II ...

    African Journals Online (AJOL)

    ABSTRACT. Infrared and Raman spectroscopy techniques have been used to study the ionic interactions of strontium(II) and barium(II) with thiocyanate ion in liquid ammonia. A number of bands were observed in both ν(CN) and ν(CS) regions of infrared and Raman spectra and these were assigned to 1:1 contact ion pair, ...

  7. Contact sensitization in Dutch children and adolescents with and without atopic dermatitis - a retrospective analysis.

    Science.gov (United States)

    Lubbes, Stefanie; Rustemeyer, Thomas; Sillevis Smitt, Johannes H; Schuttelaar, Marie Louise; Middelkamp-Hup, Maritza A

    2017-03-01

    Allergic contact dermatitis is known to occur in children with and without atopic dermatitis, but more data are needed on contact sensitization profiles in these two groups. To identify frequent allergens in children with and without atopic dermatitis suspected of having allergic contact dermatitis. A retrospective analysis of children aged 0-17 years patch tested between 1996 and 2013 was performed. Of all 1012 children tested because of suspected contact dermatitis, 46% developed one or more positive reactions, the proportions for children with (n = 526) and without (n = 395) atopic dermatitis being 48% and 47%, respectively. Children with atopic dermatitis reacted more often to lanolin alcohol (30% pet., p = 0.030), Amerchol L-101 (p = 0.030), and fragrances [fragrance mix I (p = 0.048) and Myroxylon pereirae (p = 0.005)]. Allergens outside the European baseline series that frequently gave positive reactions in these groups included cocamidopropyl betaine and Amerchol L-101. Reactivity to these allergens was significantly more common in atopic dermatitis children. Sensitization prevalences in children with and without atopic dermatitis were similar, but children with atopic dermatitis reacted significantly more often to lanolin alcohol and fragrances. Testing with additional series besides the European baseline series may be necessary, as reactions to, for example, cocamidopropyl betaine and Amerchol L-101 may otherwise be missed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Centralized processing of contact-handled TRU waste feasibility analysis

    International Nuclear Information System (INIS)

    1986-12-01

    This report presents work for the feasibility study of central processing of contact-handled TRU waste. Discussion of scenarios, transportation options, summary of cost estimates, and institutional issues are a few of the subjects discussed

  9. Evaluation of anti-tuberculosis antibodies in healthy contact and non-contacts persons

    International Nuclear Information System (INIS)

    Aziz, N; Bukhari, M.H; Muneer, M; Tayyab, M; Chaudhry, N.A.

    2006-01-01

    This study was conducted to see the presence of the antimycobacterial antibodies in healthy household contacts of tuberculosis patients and healthy normal subjects who have never been in contact with tuberculosis patients. A total of 200 subjects, 120 with history of household contact and 80 without such history were included in the study. Routine Haematological investigations were performed and all the sera of 200 subjects were tested who 19M, 19G and IgA anti tuberculosis antibodies using ELISA technique. There was no difference in the average age of the household contacts and non-contacts. The complaints of pyrexia, night sweats and loss of weight was more in house hold contacts as compared to non-contacts. The awareness about BCG vaccination was equal among the household contacts and non-contacts. The combined serological positivity of the household contacts was 65.8% and the combined serological positivity for non-contacts was 34.1%. There was no statistically significant difference in the presence of 19M among household contacts as compared to non-contacts. However both IgG and 19A were present in significantly higher number of household contacts as compared to non contacts. This study concludes that the persons living in the house with a patient suffering from active pulmonary tuberculosis (household contact) have more chances of being infected with Mycobacterium tuberculosis as compared to the healthy non-contacts. (author)

  10. Physicochemical properties of 3,4,5-trimethoxybenzoates of Mn(II, Co(II, Ni(II and Zn(II

    Directory of Open Access Journals (Sweden)

    W. FERENC

    2005-09-01

    Full Text Available The complexes of Mn(II, Co(II, Ni(II, Cu(II and Zn(II with 3,4,5-trimethoxybenzoic acid anion of the formula: M(C10H11O52·nH2O, where n = 6 for Ni(II, n = 1 for Mn(II, Co(II, Cu(II, and n = 0 for Zn, have been synthesized and characterized by elemental analysis, IR spectroscopy, X–ray diffraction measurements, thermogravimetry and magnetic studies. They are crystalline compounds characterized by various symmetry. They decompose in various ways when heated in air to 1273 K. At first, they dehydrate in one step and form anhydrous salts. The final products of decomposition are oxides of the respective metals (Mn2O3, Co3O4, NiO, CuO, ZnO. The solubilities of the analysed complexes in water at 293 K are in the orders of 10-2 – 10-4 mol dm-3. The magnetic susceptibilities of the Mn(II, Co(II, Ni(II and Cu(II complexes were measured over the range of 76–303 K and the magnetic moments were calculated. The results show that the 3,4,5-trimethoxybenzoates of Mn(II, Co(II and Ni(II are high-spin complexes but that of Cu(II forms a dimer [Cu2(C10H11O54(H2O2]. The carboxylate groups bind as monodentate or bidentate chelating or bridging ligands.

  11. Contact- and distance-based principal component analysis of protein dynamics

    Energy Technology Data Exchange (ETDEWEB)

    Ernst, Matthias; Sittel, Florian; Stock, Gerhard, E-mail: stock@physik.uni-freiburg.de [Biomolecular Dynamics, Institute of Physics, Albert Ludwigs University, 79104 Freiburg (Germany)

    2015-12-28

    To interpret molecular dynamics simulations of complex systems, systematic dimensionality reduction methods such as principal component analysis (PCA) represent a well-established and popular approach. Apart from Cartesian coordinates, internal coordinates, e.g., backbone dihedral angles or various kinds of distances, may be used as input data in a PCA. Adopting two well-known model problems, folding of villin headpiece and the functional dynamics of BPTI, a systematic study of PCA using distance-based measures is presented which employs distances between C{sub α}-atoms as well as distances between inter-residue contacts including side chains. While this approach seems prohibitive for larger systems due to the quadratic scaling of the number of distances with the size of the molecule, it is shown that it is sufficient (and sometimes even better) to include only relatively few selected distances in the analysis. The quality of the PCA is assessed by considering the resolution of the resulting free energy landscape (to identify metastable conformational states and barriers) and the decay behavior of the corresponding autocorrelation functions (to test the time scale separation of the PCA). By comparing results obtained with distance-based, dihedral angle, and Cartesian coordinates, the study shows that the choice of input variables may drastically influence the outcome of a PCA.

  12. Improving contact prediction along three dimensions.

    Directory of Open Access Journals (Sweden)

    Christoph Feinauer

    2014-10-01

    Full Text Available Correlation patterns in multiple sequence alignments of homologous proteins can be exploited to infer information on the three-dimensional structure of their members. The typical pipeline to address this task, which we in this paper refer to as the three dimensions of contact prediction, is to (i filter and align the raw sequence data representing the evolutionarily related proteins; (ii choose a predictive model to describe a sequence alignment; (iii infer the model parameters and interpret them in terms of structural properties, such as an accurate contact map. We show here that all three dimensions are important for overall prediction success. In particular, we show that it is possible to improve significantly along the second dimension by going beyond the pair-wise Potts models from statistical physics, which have hitherto been the focus of the field. These (simple extensions are motivated by multiple sequence alignments often containing long stretches of gaps which, as a data feature, would be rather untypical for independent samples drawn from a Potts model. Using a large test set of proteins we show that the combined improvements along the three dimensions are as large as any reported to date.

  13. Contact: Releasing the news

    Science.gov (United States)

    Pinotti, Roberto

    The problem of mass behavior after man's future contacts with other intelligences in the universe is not only a challenge for social scientists and political leaders all over the world, but also a cultural time bomb as well. In fact, since the impact of CETI (Contact with Extraterrestrial Intelligence) on human civilization, with its different cultures, might cause a serious socio-anthropological shock, a common and predetermined worldwide strategy is necessary in releasing the news after the contact, in order to keep possible manifestations of fear, panic and hysteria under control. An analysis of past studies in this field and of parallel historical situations as analogs suggests a definite "authority crisis" in the public as a direct consequence of an unexpected release of the news, involving a devastating "chain reaction" process (from both the psychological and sociological viewpoints) of anomie and maybe the collapse of today's society. The only way to prevent all this is to prepare the world's public opinion concerning contact before releasing the news, and to develop a long-term strategy through the combined efforts of scientists, political leaders, intelligence agencies and the mass media, in order to create the cultural conditions in which a confrontation with ETI won't affect mankind in a traumatic way. Definite roles and tasks in this multi-level model are suggested.

  14. Contact Lens Care

    Science.gov (United States)

    ... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...

  15. Numerical analysis for finite-range multitype stochastic contact financial market dynamic systems

    International Nuclear Information System (INIS)

    Yang, Ge; Wang, Jun; Fang, Wen

    2015-01-01

    In an attempt to reproduce and study the dynamics of financial markets, a random agent-based financial price model is developed and investigated by the finite-range multitype contact dynamic system, in which the interaction and dispersal of different types of investment attitudes in a stock market are imitated by viruses spreading. With different parameters of birth rates and finite-range, the normalized return series are simulated by Monte Carlo simulation method and numerical studied by power-law distribution analysis and autocorrelation analysis. To better understand the nonlinear dynamics of the return series, a q-order autocorrelation function and a multi-autocorrelation function are also defined in this work. The comparisons of statistical behaviors of return series from the agent-based model and the daily historical market returns of Shanghai Composite Index and Shenzhen Component Index indicate that the proposed model is a reasonable qualitative explanation for the price formation process of stock market systems

  16. Numerical analysis for finite-range multitype stochastic contact financial market dynamic systems

    Science.gov (United States)

    Yang, Ge; Wang, Jun; Fang, Wen

    2015-04-01

    In an attempt to reproduce and study the dynamics of financial markets, a random agent-based financial price model is developed and investigated by the finite-range multitype contact dynamic system, in which the interaction and dispersal of different types of investment attitudes in a stock market are imitated by viruses spreading. With different parameters of birth rates and finite-range, the normalized return series are simulated by Monte Carlo simulation method and numerical studied by power-law distribution analysis and autocorrelation analysis. To better understand the nonlinear dynamics of the return series, a q-order autocorrelation function and a multi-autocorrelation function are also defined in this work. The comparisons of statistical behaviors of return series from the agent-based model and the daily historical market returns of Shanghai Composite Index and Shenzhen Component Index indicate that the proposed model is a reasonable qualitative explanation for the price formation process of stock market systems.

  17. Numerical analysis for finite-range multitype stochastic contact financial market dynamic systems

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ge; Wang, Jun [School of Science, Beijing Jiaotong University, Beijing 100044 (China); Fang, Wen, E-mail: fangwen@bjtu.edu.cn [School of Economics and Management, Beijing Jiaotong University, Beijing 100044 (China)

    2015-04-15

    In an attempt to reproduce and study the dynamics of financial markets, a random agent-based financial price model is developed and investigated by the finite-range multitype contact dynamic system, in which the interaction and dispersal of different types of investment attitudes in a stock market are imitated by viruses spreading. With different parameters of birth rates and finite-range, the normalized return series are simulated by Monte Carlo simulation method and numerical studied by power-law distribution analysis and autocorrelation analysis. To better understand the nonlinear dynamics of the return series, a q-order autocorrelation function and a multi-autocorrelation function are also defined in this work. The comparisons of statistical behaviors of return series from the agent-based model and the daily historical market returns of Shanghai Composite Index and Shenzhen Component Index indicate that the proposed model is a reasonable qualitative explanation for the price formation process of stock market systems.

  18. New complexes of Co(II, Ni(II, Cu(II with Schiff base N,N’-bis-(3-methoxy-saliciliden-3,3’-dimethylbenzidine

    Directory of Open Access Journals (Sweden)

    Alan Ionela

    2013-01-01

    Full Text Available The new N,N’-bis-(3-methoxy-saliciliden-3,3’-dimetilbenzidine (H2L Schiff base and complexes with Co(II, Ni(II and Cu(II of type [M(HLCl(H2O] (M=Co(II, Cu(II [M2L(H2O4]X2 (M=Co(II, X=ClO4 and M=Cu(II, X=NO3 and [M2L(CH3COO2] (M=Co(II, Ni(II, Cu(II were synthesised. The ligand and complexes were characterized by elemental analysis, conductibility measurements, magnetic moments at room temperature, IR, NMR, UV-VIS-NIR, EPR spectra and thermogravimetric analysis. A molar ratio of 1:1 or 1:2 between ligand and metal was determined from the elemental analysis. Except for perchlorate complex that behave as electrolyte, the rest of complexes are non-electrolytes. The spectral data suggest a tetrahedral, pseudo-tetrahedral or square-planar stereochemistry respectively, data confirmed by magnetic behaviour of complexes. The antimicrobial tests indicate a fungicide effect both for ligand and complexes.

  19. Life cycle and economic efficiency analysis phase II : durable pavement markings.

    Science.gov (United States)

    2011-04-01

    This report details the Phase II analysis of the life cycle and economic efficiency of inlaid tape : and thermoplastic. Waterborne paint was included as a non-durable for comparison purposes : only. In order to find the most economical product for sp...

  20. Mechanisms of Contact Electrification at Aluminum-Polytetrafluoroethylene and Polypropylene-Water

    KAUST Repository

    Nauruzbayeva, Jamilya

    2017-04-01

    Contact electrification refers to the transfer of electrical charges between two surfaces, similar and dissimilar, as they are brought into contact and separated; this phenomenon is also known as static electrification or triboelectrification. For example, everyone has experienced weak electrical shocks from metal doorknobs, wool and synthetic clothing on dry days. While contact electrification might appear insignificant, it plays a key role in numerous natural and industrial processes, including atmospheric lightning, accumulation of dust on solar panels, charging of liquids during pipetting and flow in the tubes, and fire hazards in granular media. Contact electrification at metal-metal interfaces is well understood in terms of transfer of electrons, but a comprehensive understanding of contact electrification at interfaces of electrical insulators, such as air, water, polytetrafluoroethylene (PTFE), polypropylene remains incomplete. In fact, a variety of mechanisms responsible for transfer of electrical charges during mechanical rubbing, slipping, sliding, or flow at interfaces have been proposed via: electrons, ions, protons, hydroxide ions from water, specific orientation of dipoles, mechanoradicals, cryptoelectrons, and transfer of material. We have noticed that the extent of contact electrification of solids in water is influenced by surface free energies, mobile ions, surface roughness, duration of contact, sliding speeds, and relative humidity. Herein, we present results of our experimental investigation of contact electrification at the following interfaces: (i) PTFE-aluminum in air and (ii) polypropylene-water interfaces. To identify the underlying mechanism, we started with various hypotheses and exploited a variety of experimental techniques to falsify most of them until we got an answer; our techniques included high-voltage power supply (0-10,000 V), Faraday cages, Kelvin probe force microscopy, electrodeposition, X-ray photoelectron spectroscopy

  1. Simulation, elaboration and analysis of inter-digitated back contacts photovoltaic cells

    International Nuclear Information System (INIS)

    Nichiporuk, O.

    2005-05-01

    Solar energy is the most promising and powerful energy source among renewable energies. Photovoltaic electricity is obtained by direct transformation of the sunlight into electricity by means of photovoltaic cells. The objective of this work is to develop photovoltaic cells with back inter-digitated contacts. In the first chapter, we recall the principle of operation and the fundamental parameters of a photovoltaic cell. In a second part, we explain specificities of the inter-digitated back-contact solar cells, as well as the advantages and the disadvantages of such cells. In the second chapter we study the operation of inter-digitated back-contacts solar cells by two dimensional numerical simulation in order to optimize the geometry and doping profiles of the cell. The third chapter relates to the techniques and the methods of characterization of photovoltaic devices and components. In the fourth chapter, we describe the elaboration of inter-digitated back-contact cells. Three technological processes are presented in order to develop a simple technology for cells realization. In particular, we develop the auto-aligned technological process, which enables to elaborate the cells by using only one lithography step. In the last chapter we examine various approaches to reduce the surface recombination: SiO 2 , silicon nitride deposited by UVCVD, hydrogen annealing, etc.. (author)

  2. Simulation, elaboration and analysis of inter-digitated back-contacts photovoltaic cells

    International Nuclear Information System (INIS)

    Nichiporuk, O.

    2005-05-01

    Solar energy is the most promising and powerful energy source among renewable energies. Photovoltaic electricity is obtained by direct transformation of the sunlight into electricity by means of photovoltaic cells. The objective of this work is to develop photovoltaic cells with back inter-digitated contacts. In the first chapter, we recall the principle of operation and the fundamental parameters of a photovoltaic cell. In a second part, we explain specificities of the inter-digitated back-contact solar cells, as well as the advantages and the disadvantages of such cells. In the second chapter we study the operation of inter-digitated back-contacts solar cells by two dimensional numerical simulation in order to optimize the geometry and doping profiles of the cell. The third chapter relates to the techniques and the methods of characterization of photovoltaic devices and components. In the fourth chapter, we describe the elaboration of inter-digitated back-contact cells. Three technological processes are presented in order to develop a simple technology for cells realization. In particular, we develop the auto-aligned technological process, which enables to elaborate the cells by using only one lithography step. In the last chapter we examine various approaches to reduce the surface recombination: SiO 2 , silicon nitride deposited by UVCVD, hydrogen annealing, etc... (author)

  3. Evaluation of residue-residue contact predictions in CASP9

    KAUST Repository

    Monastyrskyy, Bohdan

    2011-01-01

    This work presents the results of the assessment of the intramolecular residue-residue contact predictions submitted to CASP9. The methodology for the assessment does not differ from that used in previous CASPs, with two basic evaluation measures being the precision in recognizing contacts and the difference between the distribution of distances in the subset of predicted contact pairs versus all pairs of residues in the structure. The emphasis is placed on the prediction of long-range contacts (i.e., contacts between residues separated by at least 24 residues along sequence) in target proteins that cannot be easily modeled by homology. Although there is considerable activity in the field, the current analysis reports no discernable progress since CASP8.

  4. Observations and Analysis of the F-type Near-Contact Binary, NSVS 1054 1123

    Science.gov (United States)

    Caton, Daniel Bruce; Samec, Ronald G.; Faulkner, Danny R.

    2018-01-01

    NSVS 1054 1123 is a F2±2 type (T~ 6750K) eclipsing binary. It was observed in April and May, 2015 at the Appalachian State University’s Dark Sky Observatory in North Carolina with the 32-inch telescope. Six times of minimum light were determined from our present observations, which include two primary eclipses and four secondary eclipses:HJD Min I = 2457113.9330 ±0. 0.0002, 24 57147.8761 ±0.0001,HJD Min II = 2457117.80391 ±0.0006, 2457136.8600 ±0. 0007, 2457148.77040 ±0.0004, 2457151.7468 ±0.0002In addition, six observations at minima were introduced as low weighted times of minimum light taken from archived NSVS Data.The following quadratic ephemerides was determined from all available times of minimum light:JD Hel Min I=2457147.87646±0.00049d + 0 .5954966±0.0000065 X E -0.0000000017± 0.0000000007 X E2A period decrease may indicate that the binary is undergoing magnetic braking and is approaching its contact configuration. A BVRcIc simultaneous (preliminary) Wilson-Devinney Program (W-D) solution indicates that the system has a mass ratio of 0.5828±0.0004, and a component temperature difference of 2350 K. The large DT in the components verify that the binary is not in contact. A Binary Maker fitted hot spot altered slightly but was not eliminated in the WD Synthetic Light Curve Computations. It remains on the larger component at the equator on the correct (following) side for a stream spot directed from the secondary component (as dictated by the Coriolis effect). This could indicate that the components are near filling their respective Roche Lobes. The fill-out of our model is -0.036 for the primary component and -0.048 for the secondary component. The inclination is ~79 degrees, not enough for the system to undergo a total eclipse.Additional and more detailed information is given in this report.

  5. Determination of kinetic and equilibrium parameters of the batch adsorption of Mn(II), Co(II), Ni(II) and Cu(II) from aqueous solution by black carrot (Daucus carota L.) residues

    International Nuclear Information System (INIS)

    Guezel, Fuat; Yakut, Hakan; Topal, Giray

    2008-01-01

    In this study, the effect of temperature on the adsorption of Mn(II), Ni(II), Co(II) and Cu(II) from aqueous solution by modified carrot residues (MCR) was investigated. The equilibrium contact times of adsorption process for each heavy metals-MCR systems were determined. Kinetic data obtained for each heavy metal by MCR at different temperatures were applied to the Lagergren equation, and adsorption rate constants (k ads ) at these temperatures were determined. These rate constants related to the adsorption of heavy metal by MCR were applied to the Arrhenius equation, and activation energies (E a ) were determined. In addition, the isotherms for adsorption of each heavy metal by MCR at different temperatures were also determined. These isothermal data were applied to linear forms of isotherm equations that they fit the Langmuir adsorption isotherm, and the Langmuir constants (q m and b) were calculated. b constants determined at different temperatures were applied to thermodynamic equations, and thermodynamic parameters such as enthalpy (ΔH), free energy (ΔG), and entropy (ΔS) were calculated and these values show that adsorption of heavy metal on MCR was an endothermic process and process of adsorption was favoured at high temperatures

  6. Synthesis and Characterization of Multimetallic Fe(II) and Mn(II ...

    African Journals Online (AJOL)

    Iron(II) and Manganese(II) complexes of the resulting ligand were obtained from its reactions with Fe(II) and Mn(II) salts in absolute methanol for the metal to ligand ratio 2:3. These complexes were characterized by Solubility, Conductivity, IR and UV-VIS spectrometry, elemental analysis and mass spectrometry. Keywords: ...

  7. RNA/DNA co-analysis from human skin and contact traces – results of a sixth collaborative EDNAP exercise

    DEFF Research Database (Denmark)

    Haas, C; Hanson, E; Banemann, R

    2015-01-01

    The European DNA profiling group (EDNAP) organized a sixth collaborative exercise on RNA/DNA co-analysis for body fluid/tissue identification and STR profiling. The task was to identify skin samples/contact traces using specific RNA biomarkers and test three housekeeping genes for their suitabili...

  8. Magnetism in Pd: Magnetoconductance and transport spectroscopy of atomic contacts

    Science.gov (United States)

    Strigl, F.; Keller, M.; Weber, D.; Pietsch, T.; Scheer, E.

    2016-10-01

    Since the rapid technological progress demands for ever smaller storage units, the emergence of stable magnetic order in nanomaterials down to the single-atom regime has attracted huge scientific attention to date. Electronic transport spectroscopy has been proven to be a versatile tool for the investigation of electronic, magnetic, and mechanical properties of atomic contacts. Here we report a comprehensive experimental study of the magnetoconductance and electronic properties of Pd atomic contacts at low temperature. The analysis of electronic transport (d I /d V ) spectra and the magnetoconductance curves yields a diverse behavior of Pd single-atom contacts, which is attributed to different contact configurations. The magnetoconductance shows a nonmonotonous but mostly continuous behavior, comparable to those found in atomic contacts of band ferromagnets. In the d I /d V spectra, frequently, a pronounced zero-bias anomaly (ZBA) as well as an aperiodic and nonsymmetric fluctuation pattern are observed. While the ZBA can be interpreted as a sign of the Kondo effect, suggesting the presence of magnetic impurity, the fluctuations are evaluated in the framework of conductance fluctuations in relation to the magnetoconductance traces and to previous findings in Au atomic contacts. This thorough analysis reveals that the magnetoconductance and transport spectrum of Au atomic contacts can completely be accounted for by conductance fluctuations, while in Pd contacts the presence of local magnetic order is required.

  9. Prediction of plastic deformation under contact condition by quasi-static and dynamic simulations using explicit finite element analysis

    International Nuclear Information System (INIS)

    Siswanto, W. A.; Nagentrau, M.; Tobi, A. L. Mohd; Tamin, M. N.

    2016-01-01

    We compared the quasi-static and dynamic simulation responses on elastic-plastic deformation of advanced alloys using Finite element (FE) method with an explicit numerical algorithm. A geometrical model consisting of a cylinder-on-flat surface contact under a normal load and sliding motion was examined. Two aeroengine materials, Ti-6Al-4V and Super CMV (Cr-Mo-V) alloy, were employed in the FE analysis. The FE model was validated by comparative magnitudes of the FE-predicted maximum contact pressure variation along the contact half-width length with the theoretical Hertzian contact solution. Results show that the (compressive) displacement of the initial contact surface steadily increases for the quasi-static load case, but accumulates at an increasing rate to the maximum level for the dynamic loading. However, the relatively higher stiffness and yield strength of the Super CMV alloy resulted in limited deformation and low plastic strain when compared to the Ti-6Al-4V alloy. The accumulated equivalent plastic strain of the material point at the initial contact position was nearly a thousand times higher for the dynamic load case (for example, 6.592 for Ti-6Al-4V, 1.0 kN) when compared to the quasi-static loading (only 0.0072). During the loading step, the von Mises stress increased with a decreasing and increasing rate for the quasi-static and dynamic load case, respectively. A sudden increase in the stress magnitude to the respective peak value was registered due to the additional constraint to overcome the static friction of the mating surfaces during the sliding step

  10. Prediction of plastic deformation under contact condition by quasi-static and dynamic simulations using explicit finite element analysis

    Energy Technology Data Exchange (ETDEWEB)

    Siswanto, W. A.; Nagentrau, M.; Tobi, A. L. Mohd [Faculty of Mechanical and Manufacturing Engineering, Universiti Tun Hussein Onn Malaysia, Batu Pahat (Malaysia); Tamin, M. N. [Faculty of Mechanical Engineering, Universiti Teknologi Malaysia, Johor Bahru (Malaysia)

    2016-11-15

    We compared the quasi-static and dynamic simulation responses on elastic-plastic deformation of advanced alloys using Finite element (FE) method with an explicit numerical algorithm. A geometrical model consisting of a cylinder-on-flat surface contact under a normal load and sliding motion was examined. Two aeroengine materials, Ti-6Al-4V and Super CMV (Cr-Mo-V) alloy, were employed in the FE analysis. The FE model was validated by comparative magnitudes of the FE-predicted maximum contact pressure variation along the contact half-width length with the theoretical Hertzian contact solution. Results show that the (compressive) displacement of the initial contact surface steadily increases for the quasi-static load case, but accumulates at an increasing rate to the maximum level for the dynamic loading. However, the relatively higher stiffness and yield strength of the Super CMV alloy resulted in limited deformation and low plastic strain when compared to the Ti-6Al-4V alloy. The accumulated equivalent plastic strain of the material point at the initial contact position was nearly a thousand times higher for the dynamic load case (for example, 6.592 for Ti-6Al-4V, 1.0 kN) when compared to the quasi-static loading (only 0.0072). During the loading step, the von Mises stress increased with a decreasing and increasing rate for the quasi-static and dynamic load case, respectively. A sudden increase in the stress magnitude to the respective peak value was registered due to the additional constraint to overcome the static friction of the mating surfaces during the sliding step.

  11. Hysteresis of Contact Angle of Sessile Droplets on Smooth Homogeneous Solid Substrates via Disjoining/Conjoining Pressure.

    Science.gov (United States)

    Kuchin, I; Starov, V

    2015-05-19

    A theory of contact angle hysteresis of liquid droplets on smooth, homogeneous solid substrates is developed in terms of the shape of the disjoining/conjoining pressure isotherm and quasi-equilibrium phenomena. It is shown that all contact angles, θ, in the range θr contact angle θ ≠ θe, correspond to the state of slow "microscopic" advancing or receding motion of the liquid if θe contact angle reaches the critical values θa or θr, correspondingly. The values of the static receding, θr, and static advancing, θa, contact angles in cylindrical capillaries were calculated earlier, based on the shape of disjoining/conjoining pressure isotherm. It is shown now that (i) both advancing and receding contact angles of a droplet on a on smooth, homogeneous solid substrate can be calculated based on shape of disjoining/conjoining pressure isotherm, and (ii) both advancing and receding contact angles depend on the drop volume and are not unique characteristics of the liquid-solid system. The latter is different from advancing/receding contact angles in thin capillaries. It is shown also that the receding contact angle is much closer to the equilibrium contact angle than the advancing contact angle. The latter conclusion is unexpected and is in a contradiction with the commonly accepted view that the advancing contact angle can be taken as the first approximation for the equilibrium contact angle. The dependency of hysteresis contact angles on the drop volume has a direct experimental confirmation.

  12. Apparent contact angle and contact angle hysteresis on liquid infused surfaces.

    Science.gov (United States)

    Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim

    2016-12-21

    We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small but finite ridge, which corresponds to an effective line tension term. We also predict contact angle hysteresis on liquid infused surfaces generated by the pinning of the contact lines by the surface corrugations. Our analytical expressions for both the apparent contact angle and contact angle hysteresis can be interpreted as 'weighted sums' between the contact angles of the infusing liquid relative to the droplet and surrounding gas phases, where the weighting coefficients are given by ratios of the fluid surface tensions.

  13. Evaluation of metal–nanowire electrical contacts by measuring contact end resistance

    International Nuclear Information System (INIS)

    Park, Hongsik; Beresford, Roderic; Xu, Jimmy; Ha, Ryong; Choi, Heon-Jin; Shin, Hyunjung

    2012-01-01

    It is known, but often unappreciated, that the performance of nanowire (NW)-based electrical devices can be significantly affected by electrical contacts between electrodes and NWs, sometimes to the extent that it is really the contacts that determine the performance. To correctly understand and design NW device operation, it is thus important to carefully measure the contact resistance and evaluate the contact parameters, specific contact resistance and transfer length. A four-terminal pattern or a transmission line model (TLM) pattern has been widely used to measure contact resistance of NW devices and the TLM has been typically used to extract contact parameters of NW devices. However, the conventional method assumes that the electrical properties of semiconducting NW regions covered by a metal are not changed after electrode formation. In this study, we report that the conventional methods for contact evaluation can give rise to considerable errors because of an altered property of the NW under the electrodes. We demonstrate that more correct contact resistance can be measured from the TLM pattern rather than the four-terminal pattern and correct contact parameters including the effects of changed NW properties under electrodes can be evaluated by using the contact end resistance measurement method. (paper)

  14. Syntheses and spectroscopic properties of mercury(II) and nickel(II ...

    African Journals Online (AJOL)

    Mercury(II) complex, [Hg2(BPTU-2H)Cl2] and nickel(II) complex, [Ni(BPTU-H)2] were prepared by reacting Bis(N-phenylthiourea), BPTU, with mercury(II) chloride and nickel(II) acetate respectively. The complexes were characterized by IR, diffuse reflectance, 1H NMR spectra and elemental analysis. BPTU acts as ...

  15. TRUPACT-II 157 Examination Report

    International Nuclear Information System (INIS)

    Barry H. O'Brien; Jeffrey M. Lacy; Kip E. Archibald

    2003-01-01

    This report presents the results of examination and recovery activities performed on the TRUPACT-II 157 shipping container. The container was part of a contact-handled transuranic waste shipment being transported on a truck to the Waste Isolation Pilot Plant in New Mexico when an accident occurred. Although the transport vehicle sustained only minor damage, airborne transuranic contamination was detected in air samples extracted from inside TRUPACT-II 157 at the Waste Isolation Pilot Plant. Consequently, the shipping container was rejected, resealed, and returned to the Idaho National Engineering and Environmental Laboratory where the payload was disassembled, examined, and recovered for subsequent reshipment to the Waste Isolation Pilot Plant. This report documents the results of those activities

  16. TRUPACT-II 157 Examination Report

    Energy Technology Data Exchange (ETDEWEB)

    Barry H. O& #39; Brien; Jeffrey M. Lacy; Kip E. Archibald

    2003-12-01

    This report presents the results of examination and recovery activities performed on the TRUPACT-II 157 shipping container. The container was part of a contact-handled transuranic waste shipment being transported on a truck to the Waste Isolation Pilot Plant in New Mexico when an accident occurred. Although the transport vehicle sustained only minor damage, airborne transuranic contamination was detected in air samples extracted from inside TRUPACT-II 157 at the Waste Isolation Pilot Plant. Consequently, the shipping container was rejected, resealed, and returned to the Idaho National Engineering and Environmental Laboratory where the payload was disassembled, examined, and recovered for subsequent reshipment to the Waste Isolation Pilot Plant. This report documents the results of those activities.

  17. In-vitro analysis of the microbicidal activity of 6 contact lens care solutions

    Directory of Open Access Journals (Sweden)

    Hildebrandt Claudia

    2012-10-01

    Full Text Available Abstract Background Contact lens-related infections are often associated with inadequate contact lens hygiene, and therefore, contact lens care products should be able to sufficiently minimise the amount of pathogens that are responsible for these infections. In 2001, the EN ISO 14729 was introduced to ensure adequate disinfection efficacy of contact lens care solutions, but this norm has recently been criticised. Methods In this study, six frequently used contact lens care solutions were retested according to the Stand Alone Test of the EN ISO 14729 (2001. The Stand Alone Test is a quantitative suspension test. In addition, the products were tested in a modified setting adding an organic load. The load was a mixture of human blood serum, lysozyme, and mucine, which resembles tear fluid. Results The criteria of the Stand Alone Test recommended in EN ISO 14729 were only met by Aosept Plus. This 3% hydrogen-peroxide-based contact lens care solution attained a reduction factor of > 5 log units for bacteria and > 4 for fungi in all cases. Two further contact lens care solutions, Blue Vision and Optifree Replenish, met the criteria of a reduction factor of > 3 log units for bacteria and > 1 log unit for fungi, but only in the presence of artificial tear fluid. The three remaining products did not exhibit adequate disinfecting efficacy, at least against one of the tested microorganisms. Conclusions Through the observation that the artificial tear fluid used in this study influences the disinfecting efficacy of contact lens care solutions, especially that of multi-purpose solutions, in a different way than does albumin, mucine, or even the organic load suggested in EN ISO 14729, it becomes obvious that the test conditions in the EN ISO 14729 should be revised in order to create more realistic conditions, e.g., by using a more realistic artificial tear fluid. Furthermore, we suggest adapting the EN ISO 14729 to the European test hierarchy for chemical

  18. Flow cytometric analysis of regulatory T cells during hyposensitization of acquired allergic contact dermatitis.

    Science.gov (United States)

    Fraser, Kathleen; Abbas, Mariam; Hull, Peter R

    2014-01-01

    We previously demonstrated that repeated intradermal steroid injections administered at weekly intervals into positive patch-test sites induce hyposensitization and desensitization. To examine changes in CD4CD25CD127lo/ regulatory T cells during the attenuation of the patch-test response. Ten patients with known allergic contact dermatitis were patch tested weekly for 10 weeks. The patch-test site was injected intradermally with 2 mg triamcinolone. At weeks 1 and 7, a biopsy was performed on the patch-test site in 6 patients, and flow cytometry was performed assessing CD4CD25CD127lo/ regulatory T cells. Secondary outcomes were clinical score, reaction size, erythema, and temperature. Statistical analysis included regression, correlation, and repeated-measures analysis of variance. The percentage of CD4CD25CD127lo/ regulatory T cells, measured by flow cytometry, increased from week 1 to week 7 by an average of 19.2%. The average grade of patch-test reaction decreased from +++ (vesicular reaction) to ++ (palpable erythema). The mean drop in temperature following treatment was 0.28°C per week. The mean area decreased 8.6 mm/wk over 10 weeks. Intradermal steroid injections of weekly patch-test reactions resulted in hyposensitization of the allergic contact dermatitis reaction. CD4CD25CD127lo/ regulatory T cells showed a tendency to increase; however, further studies are needed to determine if this is significant.

  19. 5th Contact Mechanics International Symposium

    CERN Document Server

    2013-01-01

    Contact mechanics is an active research area with deep theoretical and numerical roots. The links between nonsmooth analysis and optimization with mechanics have been investigated intensively during the last decades, especially in Europe. The study of complementarity problems, variational -, quasivariational- and hemivariational inequalities arising in contact mechanics and beyond is a hot topic for interdisciplinary research and cooperation. The needs of industry for robust solution algorithms suitable for large scale applications and the regular updates of the respective elements in major commercial computational mechanics codes, demonstrate that this interaction is not restricted to the academic environment. The contributions of this book have been selected from the participants of the CMIS 2009 international conference which took place in Crete and continued a successful series of specialized contact mechanics conferences.

  20. Electric contact arcing

    International Nuclear Information System (INIS)

    Cuthrell, R.E.

    1976-01-01

    Electrical contacts must function properly in many types of components used in nuclear weapon systems. Design, application, and testing of these components require detailed knowledge of chemical and physical phenomena associated with stockpile storage, stockpile testing, and operation. In the past, investigation of these phenomena has led to significant discoveries on the effects of surface contaminants, friction and wear, and the mechanics of closure on contact performance. A recent investigation of contact arcing phenomena which revealed that, preceding contact closure, arcs may occur at voltages lower than had been previously known is described. This discovery is important, since arcing may damage contacts, and repetitive testing of contacts performed as part of a quality assurance program might produce cumulative damage that would yield misleading life-test data and could prevent proper operation of the contacts at some time in the future. This damage can be avoided by determining the conditions under which arcing occurs, and ensuring that these conditions are avoided in contact testing

  1. Sorption of Pb(II and Cu(II by low-cost magnetic eggshells-Fe3O4 powder

    Directory of Open Access Journals (Sweden)

    Ren Jianwei

    2012-01-01

    Full Text Available This study explored the feasibility of using magnetic eggshell-Fe3O4 powder as adsorbent for the removal of Pb(II and Cu(II ions from aqueous solution. The metal ionsadsorption media interaction was characterized using XRD and FTIR. The effects of contact time, initial concentrations, temperature, solution pH and reusability of the adsorption media were investigated. The metal ions adsorption was fast and the amount of metal ions adsorbed increased with an increase in temperature, suggesting an endothermic adsorption. The kinetic data showed that the adsorption process followed the pseudo-second-order kinetic model. The optimal adsorption pH value was around 5.5 at which condition the equilibrium capacity was 263.2 mg/g for Pb(II and 250.0 for Cu(II. The adsorption equilibrium data fitted very well to the Langmuir and Freundlich adsorption isotherm models. The thermodynamics of Pb(II and Cu(II adsorption onto the magnetic eggshell-Fe3O4 powder indicated that the adsorption was spontaneous. The reusability study has proven that magnetic eggshell-Fe3O4 powder can be employed as a low-cost and easy to separate adsorbent.

  2. Molecular analysis of genetic diversity in elite II synthetic hexaploid ...

    African Journals Online (AJOL)

    The present study was conducted to assess the genetic diversity of Elite-II synthetic hexaploid (SH) wheat by genome DNA fingerprinting as revealed by random amplified polymorphic DNA (RAPD) analysis. Ten decamer RAPD primers (OPG-1, OPG-2, OPG-3, OPG-4, OPG-5, OPA-3, OPA-4, OPA-5, OPA-8, and OPA-15) ...

  3. Occlusal contacting condition and masticatory function of 2 types of pattern that differ in the closing path of the mandibular incisal point during chewing.

    Science.gov (United States)

    Watanabe, Atsushi; Shiga, Hiroshi; Kobayashi, Yoshinori

    2011-10-01

    To clarify the difference in the state of occlusal contact and masticatory function between two patterns of masticatory movement path that differed in the closing path. Fifteen healthy subjects with Pattern I (a linear or concave opening path and a convex closing path) and Pattern II (similar opening path to that in Pattern I and a concave closing path) were selected. The state of occlusal contact on the working and balancing sides and the masticatory function (integral value of the masseter muscular activity, gape, masticatory width, cycle time, indicators representing the stability of the path and rhythm, and glucose extraction) were compared between the two patterns. The occlusal contact on the working side was about the same. For the balancing side, occlusal contact at the molar region was observed for Pattern II in most cases, whereas no occlusal contact was observed for Pattern I. The integral value of the masseter muscular activity and the glucose extraction were greater for Pattern I. The gape was not different between the two patterns. Pattern I had a wide masticatory width and a short cycle time. The values of the indicators representing the stability of the path and rhythm were smaller for Pattern I. It was suggested that Pattern I with a convex closing path had a functional difference and a superior masticatory function from Pattern II with a concave closing path, and the difference in the occlusal contact on the balancing side was related. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  4. Removal of Ni(II), Zn(II) and Pb(II) ions from single metal aqueous solution using rice husk-based activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    Taha, Mohd F., E-mail: faisalt@petronas.com.my; Shaharun, Maizatul S. [Fundamental and Applied Sciences Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, 31750, Perak Darul Ridzuan (Malaysia); Shuib, Anis Suhaila, E-mail: anisuha@petronas.com.my; Borhan, Azry [Chemical Engineering Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, 31750, Perak Darul Ridzuan (Malaysia)

    2014-10-24

    An attempt was made to investigate the potential of rice husk-based activated carbon as an alternative low-cost adsorbent for the removal of Ni(II), Zn(II) and Pb(II) ions from single aqueous solution. Rice husk-based activated carbon was prepared via treatment of rice husk with NaOH followed by the carbonization process at 400°C for 2 hours. Three samples, i.e. raw rice husk, rice husk treated with NaOH and rice husk-based activated carbon, were analyzed for their morphological characteristics using field-emission scanning electron microscope/energy dispersive X-ray (FESEM/EDX). These samples were also analyzed for their carbon, hydrogen, nitrogen, oxygen and silica contents using CHN elemental analyzer and FESEM/EDX. The porous properties of rice husk-based activated carbon were determined by Brunauer-Emmett-Teller (BET) surface area analyzer, and its surface area and pore volume were 255 m{sup 2}/g and 0.17 cm{sup 2}/g, respectively. The adsorption studies for the removal of Ni(II), Zn(II) and Pb(II) ions from single metal aqueous solution were carried out at a fixed initial concentration of metal ion (150 ppm) with variation amount of adsorbent (rice husk-based activated carbon) as a function of varied contact time at room temperature. The concentration of each metal ion was analyzed using atomic absorption spectrophotometer (AAS). The results obtained from adsorption studies indicate the potential of rice husk as an economically promising precursor for the preparation of activated carbon for removal of Ni(II), Zn(II) and Pb(II) ions from single aqueous solution. Isotherm and kinetic model analyses suggested that the experimental data of adsorption studies fitted well with Langmuir, Freundlich and second-order kinetic models.

  5. Single-sweep spectral analysis of contact heat evoked potentials

    DEFF Research Database (Denmark)

    Hansen, Tine M; Graversen, Carina; Frøkjaer, Jens B

    2015-01-01

    AIMS: The cortical response to nociceptive thermal stimuli recorded as contact heat evoked potentials (CHEPs) may be altered by morphine. However, previous studies have averaged CHEPs over multiple stimuli, which are confounded by jitter between sweeps. Thus, the aim was to assess single-sweep ch......AIMS: The cortical response to nociceptive thermal stimuli recorded as contact heat evoked potentials (CHEPs) may be altered by morphine. However, previous studies have averaged CHEPs over multiple stimuli, which are confounded by jitter between sweeps. Thus, the aim was to assess single...... by 13% (P = 0.04) and 9% (P = 0.007), while the beta and gamma bands were increased by 10% (P = 0.006) and 24% (P = 0.04). CONCLUSION: The decreases in the delta and theta band are suggested to represent a decrease in the pain specific morphology of the CHEPs, which indicates a diminished pain response...

  6. Asperity interaction in adhesive contact of metallic rough surfaces

    International Nuclear Information System (INIS)

    Sahoo, Prasanta; Banerjee, Atanu

    2005-01-01

    The analysis of adhesive contact of metallic rough surfaces considering the effect of asperity interaction is the subject of this investigation. The micro-contact model of asperity interactions developed by Zhao and Chang (2001 Trans. ASME: J. Tribol. 123 857-64) is combined with the elastic plastic adhesive contact model developed by Chang et al (1988 Trans. ASME: J. Tribol. 110 50-6) to consider the asperity interaction and elastic-plastic deformation in the presence of surface forces simultaneously. The well-established elastic adhesion index and plasticity index are used to consider the different contact conditions. Results show that asperity interaction influences the load-separation behaviour in elastic-plastic adhesive contact of metallic rough surfaces significantly and, in general, adhesion is reduced due to asperity interactions

  7. Sorption and precipitation of Mn2+ by viable and autoclaved Shewanella putrefaciens: Effect of contact time

    KAUST Repository

    Chubar, Natalia; Visser, Tom; Avramut, Cristina; de Waard, Helen

    2013-01-01

    of pH, bacterial density and metal loading. During a short contact time (3-24h), the adsorptive behaviour of live and dead bacteria toward Mn(II) was sufficiently similar, an observation that was reflected in the studies on adsorption kinetics

  8. Applanation tonometry in silicone hydrogel contact lens wearers.

    Science.gov (United States)

    Allen, R J; Dev Borman, A; Saleh, G M

    2007-12-01

    Previous studies have investigated intraocular pressure (IOP) measurements through conventional soft (hydrogel) therapeutic contact lenses, and have found that an accurate IOP can be recorded in normal eyes, and in eyes with abnormal anterior segments. The IOP measurement through soft contact lenses may be affected by the water content and centre thickness of the lens. Silicone hydrogel contact lenses are now being used as therapeutic contact lenses due to their high oxygen permeability. The purpose of this study is to investigate if IOP can be accurately measured in a subject wearing a silicone hydrogel contact lens. In a cohort study, the IOP was measured with a Goldmann applanation tonometer without a contact lens and then repeated with a hydrogel contact lens in situ. The IOP of 20 eyes of 10 volunteers with no ocular pathology was measured. The mean difference (+/-S.D.) found between IOP measurement with (mean 15.55+/-1.70 mmHg) and without (mean 16.05+/-1.90 mmHg) contact lens was found to be -0.5+/-0.89 mmHg. Statistical analysis was performed which revealed a correlation coefficient of 0.89. No significant statistical difference was found between the two groups with paired t-test (p=0.19). Accurate measurement of IOP by applanation tonometry can be achieved through a silicone hydrogel contact lens.

  9. Dialect contact and the speed of Jespersen’s cycle in Middle Low German

    Directory of Open Access Journals (Sweden)

    Anne Breitbarth

    2014-12-01

    Full Text Available The present paper adds empirical evidence to the observation that dialect contact can lead to language change, and in particular, structural simplification. Empirically, the paper maps out the differences in the speed of the transition from stage II to stage III in different Middle Low German scribal dialects (Schreibsprachen and proposes an account for these differences.

  10. A Germanium Back Contact Type Thermophotovoltaic Cell

    International Nuclear Information System (INIS)

    Nagashima, Tomonori; Okumura, Kenichi; Yamaguchi, Masafumi

    2007-01-01

    A Ge back contact type photovoltaic cell has been proposed to reduce resistance loss for high current densities in thermophotovoltaic systems. The back contact structure requires less surface recombination velocities than conventional structures with front grid contacts. A SiO2/SiNx double anti-reflection coating including a high refractive index SiNx layer was studied. The SiNx layer has an enough passivation effect to obtain high efficiency. The quantum efficiency of the Ge cell was around 0.8 in the 800-1600 nm wavelength range. The conversion efficiency for infrared lights was estimated at 18% for a blackbody surface and 25% for a selective emitter by using the quantum efficiency and a simulation analysis

  11. Incident Type 2 Diabetes Risk is Influenced by Obesity and Diabetes in Social Contacts: a Social Network Analysis.

    Science.gov (United States)

    Raghavan, Sridharan; Pachucki, Mark C; Chang, Yuchiao; Porneala, Bianca; Fox, Caroline S; Dupuis, Josée; Meigs, James B

    2016-10-01

    Obesity and diabetes family history are the two strongest risk factors for type 2 diabetes (T2D). Prior work shows that an individual's obesity risk is associated with obesity in social contacts, but whether T2D risk follows similar patterns is unknown. We aimed to estimate the relationship between obesity or diabetes in an individual's social contacts and his/her T2D risk. We hypothesized that obesity and diabetes in social contacts would increase an individual's T2D risk. This was a retrospective analysis of the community-based Framingham Offspring Study (FOS). FOS participants with T2D status, height and weight, and at least one social contact were eligible for this study (n = 4797 at Exam 1). Participants' interpersonal ties, cardiometabolic and demographic variables were available at eight exams from 1971 to 2008, and a T2D additive polygenic risk score was measured at the fifth exam. Primary exposures were T2D (fasting glucose ≥ 7 mmol/L or taking diabetes medications) and obesity status (BMI ≥ 30 kg/m(2)) of social contacts at a prior exam. Primary outcome was incident T2D in participants. Incident T2D was associated with having a social contact with diabetes (OR 1.32, p = 0.004) or with obesity (OR 1.21, p = 0.004). In stratified analyses, incident T2D was associated with diabetes in siblings (OR 1.64, p = 0.001) and obesity in spouses (OR 1.54, p = 0.0004). The associations between diabetes and obesity in social contacts and an individual's incident diabetes risk were stronger in individuals with a high diabetes genetic risk score. T2D and obesity in social contacts, particularly siblings and spouses, were associated with an individual's risk of incident diabetes even after accounting for parental T2D history. Assessing risk factors in an individual's siblings and spouses can inform T2D risk; furthermore, social network based lifestyle interventions involving spouses and siblings might be a novel T2D prevention approach.

  12. Proceedings of the first analysis meeting on JUPITER-II Program

    Energy Technology Data Exchange (ETDEWEB)

    Shiradata, Keisho; Yamamoto, Masaaki [comps.

    1984-12-31

    The JUPITER-II Program is the Joint Physics Large Heterogeneous Core Critical Experiments Program between the U.S. Department of Energy (US DOE) and PNC, Japan. The experiments began in May 1982 and ended in April 1984, as a part of the ZPPR-13 program. The ZPPR-13 is a series of critical assemblies designed to study the fundamental neutronic behavior of large, radially-heterogeneous LMFBR cores. This report describes the results of analysis of ZPPR-13A and preliminary analysis of ZPPR-13B, and some topics of recent activities in fast reactor physics.

  13. Proceedings of the first analysis meeting on JUPITER-II Program

    Energy Technology Data Exchange (ETDEWEB)

    Shiradata, Keisho; Yamamoto, Masaaki [comps.

    1985-12-31

    The JUPITER-II Program is the Joint Physics Large Heterogeneous Core Critical Experiments Program between the U.S. Department of Energy (US DOE) and PNC, Japan. The experiments began in May 1982 and ended in April 1984, as a part of the ZPPR-13 program. The ZPPR-13 is a series of critical assemblies designed to study the fundamental neutronic behavior of large, radially-heterogeneous LMFBR cores. This report describes the results of analysis of ZPPR-13A and preliminary analysis of ZPPR-13B, and some topics of recent activities in fast reactor physics.

  14. Short-stack modeling of degradation in solid oxide fuel cells. Part I. Contact degradation

    Energy Technology Data Exchange (ETDEWEB)

    Gazzarri, J.I. [Department of Mechanical Engineering, University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, BC V6T 1Z4 (Canada); Kesler, O. [Department of Mechanical and Industrial Engineering, University of Toronto, 5 King' s College Road, Toronto, ON M5S 3G8 (Canada)

    2008-01-21

    As the first part of a two paper series, we present a two-dimensional impedance model of a working solid oxide fuel cell (SOFC) to study the effect of contact degradation on the impedance spectrum for the purpose of non-invasive diagnosis. The two dimensional modeled geometry includes the ribbed interconnect, and is adequate to represent co- and counter-flow configurations. Simulated degradation modes include: cathode delamination, interconnect oxidation, and interconnect-cathode detachment. The simulations show differences in the way each degradation mode impacts the impedance spectrum shape, suggesting that identification is possible. In Part II, we present a sensitivity analysis of the results to input parameter variability that reveals strengths and limitations of the method, as well as describing possible interactions between input parameters and concurrent degradation modes. (author)

  15. Short-stack modeling of degradation in solid oxide fuel cells. Part I. Contact degradation

    Science.gov (United States)

    Gazzarri, J. I.; Kesler, O.

    As the first part of a two paper series, we present a two-dimensional impedance model of a working solid oxide fuel cell (SOFC) to study the effect of contact degradation on the impedance spectrum for the purpose of non-invasive diagnosis. The two dimensional modeled geometry includes the ribbed interconnect, and is adequate to represent co- and counter-flow configurations. Simulated degradation modes include: cathode delamination, interconnect oxidation, and interconnect-cathode detachment. The simulations show differences in the way each degradation mode impacts the impedance spectrum shape, suggesting that identification is possible. In Part II, we present a sensitivity analysis of the results to input parameter variability that reveals strengths and limitations of the method, as well as describing possible interactions between input parameters and concurrent degradation modes.

  16. Resistance of Acanthamoeba cysts to disinfection in multiple contact lens solutions.

    Science.gov (United States)

    Johnston, Stephanie P; Sriram, Rama; Qvarnstrom, Yvonne; Roy, Sharon; Verani, Jennifer; Yoder, Jonathan; Lorick, Suchita; Roberts, Jacquelin; Beach, Michael J; Visvesvara, Govinda

    2009-07-01

    Acanthamoebae are free-living amoebae found in the environment, including soil, freshwater, brackish water, seawater, hot tubs, and Jacuzzis. Acanthamoeba species can cause keratitis, a painful vision-threatening infection of the cornea, and fatal granulomatous encephalitis in humans. More than 20 species of Acanthamoeba belonging to morphological groups I, II, and III distributed in 15 genotypes have been described. Among these, Acanthamoeba castellanii, A. polyphaga, and A. hatchetti are frequently identified as causing Acanthamoeba keratitis (AK). Improper contact lens care and contact with nonsterile water while wearing contact lenses are known risk factors for AK. During a recent multistate outbreak, AK was found to be associated with the use of Advanced Medical Optics Complete MoisturePlus multipurpose contact lens solution, which was hypothesized to have had insufficient anti-Acanthamoeba activity. As part of the investigation of that outbreak, we compared the efficacies of 11 different contact lens solutions against cysts of A. castellanii, A. polyphaga, and A. hatchetti (the isolates of all species were genotype T4), which were isolated in 2007 from specimens obtained during the outbreak investigation. The data, generated with A. castellanii, A. polyphaga, and A. hatchetti cysts, suggest that the two contact lens solutions containing hydrogen peroxide were the only solutions that showed any disinfection ability, with 0% and 66% growth, respectively, being detected with A. castellanii and 0% and 33% growth, respectively, being detected with A. polyphaga. There was no statistically significant difference in disinfection efficacy between the 11 solutions for A. hatchetti.

  17. Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Meltem Önder

    2009-03-01

    Full Text Available Allergic contact dermatitis is the delayed type hypersensitivity reaction to exogenous agents. Allergic contact dermatitis may clinically present acutely after allergen exposure and initial sensitization in a previously sensitized individual. Acute phase is characterized by erythematous, scaly plaques. In severe cases vesiculation and bullae in exposed areas are very characteristic. Repeated or continuous exposure of sensitized individual with allergen result in chronic dermatitis. Lichenification, erythematous plaques, hyperkeratosis and fissuring may develop in chronic patients. Allergic contact dermatitis is very common dermatologic problem in dermatology daily practice. A diagnosis of contact dermatitis requires the careful consideration of patient history, physical examination and patch testing. The knowledge of the clinical features of the skin reactions to various contactans is important to make a correct diagnosis of contact dermatitis. It can be seen in every age, in children textile product, accessories and touch products are common allergens, while in adults allergic contact dermatitis may be related with topical medicaments. The contact pattern of contact dermatitis depends on fashion and local traditions as well. The localization of allergic reaction should be evaluated and patients’ occupation and hobbies should be asked. The purpose of this review is to introduce to our collaques up dated allergic contact dermatitis literatures both in Turkey and in the World.

  18. Adhesive friction for elastic-plastic contacting rough surfaces considering asperity interaction

    International Nuclear Information System (INIS)

    Sahoo, Prasanta

    2006-01-01

    The paper describes a theoretical study of adhesive friction at the contact between rough surfaces taking asperity interaction into consideration and using an elastic-plastic model of contact deformation that is based on an accurate finite element analysis of an elastic-plastic single asperity contact. The micro-contact model of asperity interactions, developed by Zhao and Chang, is integrated into the improved elastic-plastic rough surface adhesive contact analysis to consider the adhesive friction behaviour of rough surfaces. The model considers a large range of interference values from fully elastic through elastic-plastic to fully plastic regimes of contacting asperities. Two well-established adhesion indices are used to consider different conditions that arise as a result of varying load, surface and material parameters. Results are obtained for the coefficient of friction against applied load for various combinations of these parameters. The results show that the coefficient of friction depends strongly on the applied load for the no-interaction case while it becomes insensitive to the load for interaction consideration. Moreover, the inclusion of elastic-plastic asperities further reduces the friction coefficient

  19. TRUPACT-II, a regulatory perspective

    International Nuclear Information System (INIS)

    Gregory, P.C.; Spooner, O.R.

    1995-01-01

    The Transuranic Package Transporter II (TRUPACT-II) is a US Nuclear Regulatory Commission (NRC) certified Type B packaging for the shipment of contact-handled transuranic (CH-TRU) material by the US Department of Energy (DOE). The NRC approved the TRUPACT-II design as meeting the requirements of Title 10, Code of Federal Regulations, Part 71 (10 CFR 71) and issued Certificate of Compliance (CofC) Number 9218 to the DOE. There are currently 15 certified TRUPACT-IIs. Additional TRUPACT-IIs will be required to make more than 15,000 shipments of CH-TRU waste to the Waste Isolation Pilot Plant (WIPP) site near Carlsbad, New Mexico. The TRUPACT-II may also be used for the DOE inter-site and intra-site shipments of CH-TRU waste. The Land Withdrawal Act (Public Law 102-579), enacted by the US Congress, October 30, 1992, and an agreement between the DOE and the State of New Mexico, signed August 4, 1987, both stipulate that only NRC approved packaging may be used for shipments of TRU waste to the WIPP. Early in the TRUPACT-II development phase it was decided that the transportation system (tractor, trailer, and TRUPACT-II) should be highway legal on all routes without the need for oversize and/or overweight permits. In large measure, public acceptance of the DOE's efforts to safely transport CH-TRU waste depends on the public's perception that the TRUPACT-II is in compliance with all applicable regulations, standards, and quality assurance requirements. This paper addresses some of the numerous regulations applicable to Type B packaging, and it describes how the TRUPACT-II complies with these regulations

  20. Contralateral limb during total contact casting. A dynamic pressure and thermometric analysis.

    Science.gov (United States)

    Armstrong, D G; Liswood, P J; Todd, W F

    1995-12-01

    The authors draw attention to the importance of evaluation of the contralateral limb when treating unilateral sequelae secondary to distal symmetrical polyneuropathy. Plantar pressure measurements of the contralateral limb during total contact casting are reviewed. The results of thermometric evaluation before and after initiation of repetitive stress were reviewed. The results suggest that the patient walking in a total contact cast may experience a reduced focal pressure on the contralateral limb when compared with uncasted walking and three-point walking with crutches. Dermal thermometry may be a highly sensitive tool in evaluating even mild increases in repetitive stress. To explain this decrease in contralateral stress, the authors examine the features inherent to the total contact cast and propose the concept of proprioceptive stability.

  1. Contact allergy to preservatives in patients with occupational contact dermatitis and exposure analysis of preservatives in registered chemical products for occupational use

    DEFF Research Database (Denmark)

    Schwensen, Jakob Ferløv; Friis, Ulrik Fischer; Menné, Torkil

    2017-01-01

    PURPOSE: The aim of the study is to investigate risk factors for sensitization to preservatives and to examine to which extent different preservatives are registered in chemical products for occupational use in Denmark. METHODS: A retrospective epidemiological observational analysis of data from...... a university hospital was conducted. All patients had occupational contact dermatitis and were consecutively patch tested with 11 preservatives from the European baseline series and extended patch test series during a 5-year period: 2009-2013. Information regarding the same preservatives in chemical products...... in several product categories, e.g., 'paints and varnishes', 'cleaning agents', 'cooling agents', and 'polishing agents'. Formaldehyde and isothiazolinones were extensively registered in PROBAS. CONCLUSIONS: The extensive use of formaldehyde and isothiazolinones in chemical products for occupational use may...

  2. Analysis of bearing steel exposed to rolling contact fatigue

    DEFF Research Database (Denmark)

    Hansen, K. T.; Fæster, Søren; Natarajan, Anand

    2017-01-01

    The objective of this work is to characterize fatigue damage in roller bearings under conditions of high load and slippage. A test rig constructed for rolling contact fatigue tests of rings is described, and test results are presented for rings taken from two spherical roller bearings. The prepar...

  3. Bioinformatic Analysis of Plasma Apolipoproteins A-I and A-II Revealed Unique Features of A-I/A-II HDL Particles in Human Plasma

    Science.gov (United States)

    Kido, Toshimi; Kurata, Hideaki; Kondo, Kazuo; Itakura, Hiroshige; Okazaki, Mitsuyo; Urata, Takeyoshi; Yokoyama, Shinji

    2016-01-01

    Plasma concentration of apoA-I, apoA-II and apoA-II-unassociated apoA-I was analyzed in 314 Japanese subjects (177 males and 137 females), including one (male) homozygote and 37 (20 males and 17 females) heterozygotes of genetic CETP deficiency. ApoA-I unassociated with apoA-II markedly and linearly increased with HDL-cholesterol, while apoA-II increased only very slightly and the ratio of apoA-II-associated apoA-I to apoA-II stayed constant at 2 in molar ratio throughout the increase of HDL-cholesterol, among the wild type and heterozygous CETP deficiency. Thus, overall HDL concentration almost exclusively depends on HDL with apoA-I without apoA-II (LpAI) while concentration of HDL containing apoA-I and apoA-II (LpAI:AII) is constant having a fixed molar ratio of 2 : 1 regardless of total HDL and apoA-I concentration. Distribution of apoA-I between LpAI and LpAI:AII is consistent with a model of statistical partitioning regardless of sex and CETP genotype. The analysis also indicated that LpA-I accommodates on average 4 apoA-I molecules and has a clearance rate indistinguishable from LpAI:AII. Independent evidence indicated LpAI:A-II has a diameter 20% smaller than LpAI, consistent with a model having two apoA-I and one apoA-II. The functional contribution of these particles is to be investigated. PMID:27526664

  4. Experimental investigation on the electrical contact behavior of rolling contact connector

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Junxing; Yang, Fei, E-mail: yfei2007@mail.xjtu.edu.cn; Luo, Kaiyu; Zhu, Mingliang; Wu, Yi; Rong, Mingzhe [State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049 (China)

    2015-12-15

    Rolling contact connector (RCC) is a new technology utilized in high performance electric power transfer systems with one or more rotating interfaces, such as radars, satellites, wind generators, and medical computed tomography machines. Rolling contact components are used in the RCC instead of traditional sliding contacts to transfer electrical power and/or signal. Since the requirement of the power transmission is increasing in these years, the rolling electrical contact characteristics become more and more important for the long-life design of RCC. In this paper, a typical form of RCC is presented. A series of experimental work are carried out to investigate the rolling electrical contact characteristics during its lifetime. The influence of a variety of factors on the electrical contact degradation behavior of RCC is analyzed under both vacuum and air environment. Based on the surface morphology and elemental composition changes in the contact zone, which are assessed by field emission scanning electron microscope and confocal laser scanning microscope, the mechanism of rolling electrical contact degradation is discussed.

  5. Optimal design of the gerotor (2-ellipses) for reducing maximum contact stress

    Energy Technology Data Exchange (ETDEWEB)

    Kwak, Hyo Seo; Li, Sheng Huan [Dept. of Mechanical Convergence Technology, Pusan National University, Busan (Korea, Republic of); Kim, Chul [School of Mechanical Design and Manufacturing, Busan Institute of Science and Technology, Busan (Korea, Republic of)

    2016-12-15

    The oil pump, which is used as lubricator of engines and auto transmission, supplies working oil to the rotating elements to prevent wear. The gerotor pump is used widely in the automobile industry. When wear occurs due to contact between an inner rotor and an outer rotor, the efficiency of the gerotor pump decreases rapidly, and elastic deformation from the contacts also causes vibration and noise. This paper reports the optimal design of a gerotor with a 2-ellipses combined lobe shape that reduces the maximum contact stress. An automatic program was developed to calculate Hertzian contact stress of the gerotor using the Matlab and the effect of the design parameter on the maximum contact stress was analyzed. In addition, the method of theoretical analysis for obtaining the contact stress was verified by performing the fluid-structural coupled analysis using the commercial software, Ansys, considering both the driving force of the inner rotor and the fluid pressure, which is generated by working oil.

  6. CONTACT RESISTANCE MODELING

    Directory of Open Access Journals (Sweden)

    S. V. LOSKUTOV

    2018-05-01

    Full Text Available Purpose. To determine the contribution of the real contact spots distribution in the total conductivity of the conductors contact. Methodology. The electrical contact resistance research was carried out on models. The experimental part of this work was done on paper with a graphite layer with membranes (the first type and conductive liquids with discrete partitions (the second type. Findings. It is shown that the contact electrical resistance is mainly determined by the real area of metal contact. The experimental dependence of the electrical resistance of the second type model on the distance between the electrodes and the potential distribution along the sample surface for the first type model were obtained. The theoretical model based on the principle of electric field superposition was considered. The dependences obtained experimentally and calculated by using the theoretical model are in good agreement. Originality. The regularity of the electrical contact resistance formation on a large number of membranes was researched for the first time. A new model of discrete electrical contact based on the liquid as the conducting environment with nuclear membrane partitions was developed. The conclusions of the additivity of contact and bulk electrical resistance were done. Practical value. Based on these researches, a new experimental method of kinetic macroidentation that as a parameter of the metal surface layer deformation uses the real contact area was developed. This method allows to determine the value of average contact stresses, yield point, change of the stress on the depth of deformation depending on the surface treatment.

  7. Sorption Efficiency of a New Sorbent towards Cadmium(II: Methylphosphonic Acid Grafted Polystyrene Resin

    Directory of Open Access Journals (Sweden)

    Nacer Ferrah

    2013-01-01

    Full Text Available A new chelating polymeric sorbent has been developed using polystyrene resin grafted with phosphonic acid. After characterization by FTIR and elementary analysis, the new resin has been investigated in liquid-solid extraction of cadmium(II. The results indicated that phosphonic resin could adsorb Cd(II ion effectively from aqueous solution. The adsorption was strongly dependent on the pH of the medium and the optimum pH value level for better sorption was between 3.2 and 5.2. The influence of other analytical parameters including contact time, amount of resin, metal ion concentration, and the presence of some electrolytes was investigated. The maximum uptake capacity of Cd(II ions was 37,9 mg·g−1 grafted resin at ambient temperature, at an initial pH value of 5.0. The overall adsorption process was best described by pseudo second-order kinetic. When Freundlich and Langmuir isotherms were tested, the latter had a better fit with the experimental data. Furthermore, more than 92% of Cd(II could be eluted by using 1.0 mol·L−1 HCl in one cycle.

  8. Adsorption dynamics and equilibrium studies of Zn (II)

    Indian Academy of Sciences (India)

    Batch equilibration studies are conducted to determine the nature of adsorption of zinc (II) over chitosan. The factors affecting the adsorption process like particle size, contact time, dosage, pH, effects of chloride and nitrate are identified. The influence of temperature and co-ions on the adsorption process is verified.

  9. Non-contact method of search and analysis of pulsating vessels

    Science.gov (United States)

    Avtomonov, Yuri N.; Tsoy, Maria O.; Postnov, Dmitry E.

    2018-04-01

    Despite the variety of existing methods of recording the human pulse and a solid history of their development, there is still considerable interest in this topic. The development of new non-contact methods, based on advanced image processing, caused a new wave of interest in this issue. We present a simple but quite effective method for analyzing the mechanical pulsations of blood vessels lying close to the surface of the skin. Our technique is a modification of imaging (or remote) photoplethysmography (i-PPG). We supplemented this method with the addition of a laser light source, which made it possible to use other methods of searching for the proposed pulsation zone. During the testing of the method, several series of experiments were carried out with both artificial oscillating objects as well as with the target signal source (human wrist). The obtained results show that our method allows correct interpretation of complex data. To summarize, we proposed and tested an alternative method for the search and analysis of pulsating vessels.

  10. Friction and universal contact area law for randomly rough viscoelastic contacts.

    Science.gov (United States)

    Scaraggi, M; Persson, B N J

    2015-03-18

    We present accurate numerical results for the friction force and the contact area for a viscoelastic solid (rubber) in sliding contact with hard, randomly rough substrates. The rough surfaces are self-affine fractal with roughness over several decades in length scales. We calculate the contribution to the friction from the pulsating deformations induced by the substrate asperities. We also calculate how the area of real contact, A(v, p), depends on the sliding speed v and on the nominal contact pressure p, and we show how the contact area for any sliding speed can be obtained from a universal master curve A(p). The numerical results are found to be in good agreement with the predictions of an analytical contact mechanics theory.

  11. Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis

    DEFF Research Database (Denmark)

    Koppes, Sjors A.; Engebretsen, Kristiane A.; Agner, Tove

    2017-01-01

    Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant...... and atopic dermatitis. Several studies have examined the pathogenesis and severity of allergic contact dermatitis by measuring the absence or presence of various biomarkers. In this review, we provide a non-systematic overview of biomarkers that have been studied in allergic contact dermatitis. These include...... genetic variations and mutations, inflammatory mediators, alarmins, proteases, immunoproteomics, lipids, natural moisturizing factors, tight junctions, and antimicrobial peptides. We conclude that, despite the enormous amount of data, convincing specific biomarkers for allergic contact dermatitis are yet...

  12. Coordinate transformation in the model of long Josephson contacts: geometrically equivalent contacts

    International Nuclear Information System (INIS)

    Semerdzhieva, E.G.; Boyadzhiev, T.L.; ); Shukrinov, Yu.M.; Physical Technical Institute Dushanbe, 734063

    2005-01-01

    The transition from model of long Josephson variable-width contact to the contact model with coordinate-dependent Josephson current amplitude is realized by transforming the coordinates. This sets up a correspondence between Josephson contacts of variable width and quasi-one-dimensional contacts of variable thickness barrier layer. It is shown, that for contacts of exponentially varying width the barrier layer of the corresponding quasi-one-dimensional contact contains the distributed resistive inhomogeneity which is an attractor to magnetic flux vortices. With numerical experiments, a 'critical current-magnetic field' dependence for a resistive microinhomogeneity Josephson contact was plotted, and its comparison with the critical curve for a contact of exponentially varying width was made. Thus, this demonstrates that the distributed inhomogeneity may be replaced by a local one at the JC end what technologically, may offer definite advantages

  13. Simulation Results: Optimization of Contact Ratio for Interdigitated Back-Contact Solar Cells

    Directory of Open Access Journals (Sweden)

    Vinay Budhraja

    2017-01-01

    Full Text Available In the fabrication of interdigitated back contact (IBC solar cells, it is very important to choose the right size of contact to achieve the maximum efficiency. Line contacts and point contacts are the two possibilities, which are being chosen for IBC structure. It is expected that the point contacts would give better results because of the reduced recombination rate. In this work, we are simulating the effect of contact size on the performance of IBC solar cells. Simulations were done in three dimension using Quokka, which numerically solves the charge carrier transport. Our simulation results show that around 10% of contact ratio is able to achieve optimum cell efficiency.

  14. Dynamics of social contagions with limited contact capacity.

    Science.gov (United States)

    Wang, Wei; Shu, Panpan; Zhu, Yu-Xiao; Tang, Ming; Zhang, Yi-Cheng

    2015-10-01

    Individuals are always limited by some inelastic resources, such as time and energy, which restrict them to dedicate to social interaction and limit their contact capacities. Contact capacity plays an important role in dynamics of social contagions, which so far has eluded theoretical analysis. In this paper, we first propose a non-Markovian model to understand the effects of contact capacity on social contagions, in which each adopted individual can only contact and transmit the information to a finite number of neighbors. We then develop a heterogeneous edge-based compartmental theory for this model, and a remarkable agreement with simulations is obtained. Through theory and simulations, we find that enlarging the contact capacity makes the network more fragile to behavior spreading. Interestingly, we find that both the continuous and discontinuous dependence of the final adoption size on the information transmission probability can arise. There is a crossover phenomenon between the two types of dependence. More specifically, the crossover phenomenon can be induced by enlarging the contact capacity only when the degree exponent is above a critical degree exponent, while the final behavior adoption size always grows continuously for any contact capacity when degree exponent is below the critical degree exponent.

  15. Articular contact in a three-dimensional model of the knee

    NARCIS (Netherlands)

    Blankevoort, L.; Kuiper, J. H.; Huiskes, R.; Grootenboer, H. J.

    1991-01-01

    This study is aimed at the analysis of articular contact in a three-dimensional mathematical model of the human knee-joint. In particular the effect of articular contact on the passive motion characteristics is assessed in relation to experimentally obtained joint kinematics. Two basically different

  16. Occupational protein contact dermatitis.

    Science.gov (United States)

    Barbaud, Annick; Poreaux, Claire; Penven, Emmanuelle; Waton, Julie

    2015-01-01

    Occupational contact dermatitis is generally caused by haptens but can also be induced by proteins causing mainly immunological contact urticaria (ICU); chronic hand eczema in the context of protein contact dermatitis (PCD). In a monocentric retrospective study, from our database, only 31 (0.41%) of patients with contact dermatitis had positive skin tests with proteins: 22 had occupational PCD, 3 had non-occupational PCD, 5 occupational ICU and 1 cook had a neutrophilic fixed food eruption (NFFE) due to fish. From these results and analysis of literature, the characteristics of PCD can be summarized as follows. It is a chronic eczematous dermatitis, possibly exacerbated by work, suggestive if associated with inflammatory perionyxix and immediate erythema with pruritis, to be investigated when the patient resumes work after a period of interruption. Prick tests with the suspected protein-containing material are essential, as patch tests have negative results. In case of multisensitisation revealed by prick tests, it is advisable to analyse IgE against recombinant allergens. A history of atopy, found in 56 to 68% of the patients, has to be checked for. Most of the cases are observed among food-handlers but PCD can also be due to non-edible plants, latex, hydrolysed proteins or animal proteins. Occupational exposure to proteins can thus lead to the development of ICU. Reflecting hypersensitivity to very low concentrations of allergens, investigating ICU therefore requires caution and prick tests should be performed with a diluted form of the causative protein-containing product. Causes are food, especially fruit peel, non-edible plants, cosmetic products, latex, animals.

  17. Comparative meta-analysis of tuberculosis contact investigation interventions in eleven high burden countries

    NARCIS (Netherlands)

    Blok, Lucie; Sahu, Suvanand; Creswell, Jacob; Alba, Sandra; Stevens, Robert; Bakker, Mirjam I.

    2015-01-01

    Screening of household contacts of tuberculosis (TB) patients is a recommended strategy to improve early case detection. While it has been widely implemented in low prevalence countries, the most optimal protocols for contact investigation in high prevalence, low resource settings is yet to be

  18. FASTRAN II - FATIGUE CRACK GROWTH STRUCTURAL ANALYSIS (UNIX VERSION)

    Science.gov (United States)

    Newman, J. C.

    1994-01-01

    Predictions of fatigue crack growth behavior can be made with the Fatigue Crack Growth Structural Analysis (FASTRAN II) computer program. As cyclic loads are applied to a selected crack configuration with an initial crack size, FASTRAN II predicts crack growth as a function of cyclic load history until either a desired crack size is reached or failure occurs. FASTRAN II is based on plasticity-induced crack-closure behavior of cracks in metallic materials and accounts for load-interaction effects, such as retardation and acceleration, under variable-amplitude loading. The closure model is based on the Dugdale model with modifications to allow plastically deformed material to be left along the crack surfaces as the crack grows. Plane stress and plane strain conditions, as well as conditions between these two, can be simulated in FASTRAN II by using a constraint factor on tensile yielding at the crack front to approximately account for three-dimensional stress states. FASTRAN II contains seventeen predefined crack configurations (standard laboratory fatigue crack growth rate specimens and many common crack configurations found in structures); and the user can define one additional crack configuration. The baseline crack growth rate properties (effective stress-intensity factor against crack growth rate) may be given in either equation or tabular form. For three-dimensional crack configurations, such as surface cracks or corner cracks at holes or notches, the fatigue crack growth rate properties may be different in the crack depth and crack length directions. Final failure of the cracked structure can be modelled with fracture toughness properties using either linear-elastic fracture mechanics (brittle materials), a two-parameter fracture criterion (brittle to ductile materials), or plastic collapse (extremely ductile materials). The crack configurations in FASTRAN II can be subjected to either constant-amplitude, variable-amplitude or spectrum loading. The applied

  19. Thermal stability analysis and auxiliary power feedback control for the tokamak engineering test breeder (TETB-II)

    International Nuclear Information System (INIS)

    Sheng Guangzhao

    1993-01-01

    The thermal stability of TETB-II is analyzed using different methods, viz., POPCON, linear stability analysis and the time evolution calculation of plasma parameters. A thermal instability of the TETB-II is predicted. Auxiliary power feedback control for thermal stability appears feasible and efficient

  20. Removal of Copper(II) Ions in Aqueous Solutions Using Tannin-Rich Plants as Natural Bio-Adsorbents

    Science.gov (United States)

    Paksamut, J.; Boonsong, P.

    2018-03-01

    In this study, the purpose of our interest is to investigatethe adsorption behavior of copper (II) ions in aqueous solution using some tannin-rich plants as natural bio-adsorbents such as mangosteen peels (Garciniamangostana L.), cassava leaves (Manihotesculenta Crantz) and Thai copper pod leaves (Sennasiamea (Lam.)) as powder form in different dosage of adsorbent plant materials.The adsorption capacities at different pH of solution and contact time were performed.All the experiments in this studywere chosen at room temperature by batch technique. From the experimental results showed that cassava leaves gave better adsorbent properties than mangosteen peels and Thai copper pod leaves. The increasing dosage of all adsorbents and contact time have been found to increase adsorption capacities. In this respect, the adsorption capacities depend crucially on the adsorbents and contact time. The optimum pH of copper (II) ions adsorption was pH4. According to this work, it was observed that bioadsorbent materials from tannin-rich plants could be used to remove copper (II) ions from aqueous solutions.

  1. Measurement and visualization of file-to-wall contact during ultrasonically activated irrigation in simulated canals.

    Science.gov (United States)

    Boutsioukis, C; Verhaagen, B; Walmsley, A D; Versluis, M; van der Sluis, L W M

    2013-11-01

    (i) To quantify in a simulated root canal model the file-to-wall contact during ultrasonic activation of an irrigant and to evaluate the effect of root canal size, file insertion depth, ultrasonic power, root canal level and previous training, (ii) To investigate the effect of file-to-wall contact on file oscillation. File-to-wall contact was measured during ultrasonic activation of the irrigant performed by 15 trained and 15 untrained participants in two metal root canal models. Results were analyzed by two 5-way mixed-design anovas. The level of significance was set at P root canal (P root canal (P irrigant activation. Therefore, the term 'Passive Ultrasonic Irrigation' should be amended to 'Ultrasonically Activated Irrigation'. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  2. Measurement and visualization of file-to-wall contact during ultrasonically activated irrigation in simulated canals

    NARCIS (Netherlands)

    Boutsioukis, C.; Verhaagen, B.; Walmsley, A.D.; Versluis, Michel; van der Sluis, L.W.M.

    2013-01-01

    Aim (i) To quantify in a simulated root canal model the file-to-wall contact during ultrasonic activation of an irrigant and to evaluate the effect of root canal size, file insertion depth, ultrasonic power, root canal level and previous training, (ii) To investigate the effect of file-to-wall

  3. Measurement and visualization of file-to-wall contact during ultrasonically activated irrigation in simulated canals

    NARCIS (Netherlands)

    Boutsioukis, C.; Verhaagen, B.; Walmsley, A. D.; Versluis, M.; van der Sluis, L. W. M.

    2013-01-01

    Aim(i) To quantify in a simulated root canal model the file-to-wall contact during ultrasonic activation of an irrigant and to evaluate the effect of root canal size, file insertion depth, ultrasonic power, root canal level and previous training, (ii) To investigate the effect of file-to-wall

  4. An Analysis Plan for the ARCOMS II (Armor Combat Operations Model Support II) Experiment.

    Science.gov (United States)

    1983-06-01

    In order to facilitate Armor Combat Modeling, the data analysis shculd focus upon the methods which transform the data intc descriptive or predictive ...discussed in Chapter III tc predict the Farameter for probability of detection in time ŕt. This should be compared with the results of the N.4gh -t Vision...J 6A 46.) I-I 0 f U-CL 0~ z o -Z 06 09 03 v 0 0 SJldnYS 10 ON Ipgr Cp o LSTm n at emn itgas 4AA rI z ;A (AZ - 090.0 UlA0 -O ON 404 Fiur CAd &P CC

  5. Mechanical Design and Analysis of LCLS II 2 K Cold Box

    Science.gov (United States)

    Yang, S.; Dixon, K.; Laverdure, N.; Rath, D.; Bevins, M.; Bai, H.; Kaminski, S.; Ravindranath, V.

    2017-12-01

    The mechanical design and analysis of the LCLS II 2 K cold box are presented. Its feature and functionality are discussed. ASME B31.3 was used to design its internal piping, and compliance of the piping code was ensured through flexibility analysis. The 2 K cold box was analyzed using ANSYS 17.2; the requirements of the applicable codes—ASME Section VIII Division 2 and ASCE 7-10—were satisfied. Seismic load was explicitly considered in both analyses.

  6. Association between cancer and contact allergy: a linkage study

    DEFF Research Database (Denmark)

    Engkilde, Kaare; Thyssen, Jacob P; Menné, Torkil

    2011-01-01

    by logistic regression analysis. Results An inverse association between contact allergy and non-melanoma skin- and breast cancer, respectively, was identified in both sexes, and an inverse trend for brain cancer was found in women with contact allergy. Additionally, a positive association between contact...... allergy and bladder cancer was found. Conclusion The inverse associations support the immunosurveillance hypothesis (ie, individuals with an allergy are less likely to get cancer due to a triggered immune system), while the positive association with bladder cancer could be due to accumulations of chemical...

  7. Occupations at risk of developing contact allergy to isothiazolinones in Danish contact dermatitis patients: results from a Danish multicentre study (2009-2012).

    Science.gov (United States)

    Schwensen, Jakob F; Menné, Torkil; Andersen, Klaus E; Sommerlund, Mette; Johansen, Jeanne D

    2014-11-01

    In recent years, the prevalence of contact allergy to isothiazolinones has reached epidemic levels. Few studies have presented data on occupations at risk of developing contact allergy to isothiazolinones. To present demographics and examine risk factors for sensitization to methylisothiazolinone (MI), methylchloroisothiazolinone (MCI) in combination with MI and benzisothiazolinone (BIT) in Danish dermatitis patients. A retrospective epidemiological analysis of data from three Danish hospitals departments was conducted. All patients consecutively patch tested with MI, MCI/MI and BIT between 2009 and 2013 were included. MI contact allergy showed a significantly increased trend in prevalence from 1.8% in 2009 to 4.2% in 2012 (p dermatitis mainly drove the increase in 2012. Adjusted logistic regression analysis showed that MI sensitization was significantly associated with occupational exposures, hand and facial dermatitis, age > 40 years, and the occupational groups of tile setters/terrazzo workers, machine operators, and painters. MCI/MI contact allergy was significantly associated with the following high-risk occupations: painting, welding (blacksmiths), machine operating, and cosmetology. The occupational group of painting was frequent in the group of patients with BIT contact allergy. Several high-risk occupations for sensitization to isothiazolinones exist. Regulation on the allowed concentration of isothiazolinones, and especially MI, in both consumer products and industrial products is needed. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Impact of a commercial glyphosate formulation on adsorption of Cd(II) and Pb(II) ions on paddy soil.

    Science.gov (United States)

    Divisekara, T; Navaratne, A N; Abeysekara, A S K

    2018-05-01

    Use of glyphosate as a weedicide on rice cultivation has been a controversial issue in Sri Lanka, due to the hypothesis that the metal complexes of commercial glyphosate is one of the causative factors of Chronic Kidney Disease of unknown aetiology (CKDu) prevalent in some parts of Sri Lanka. The effect of commercial glyphosate on the adsorption and desorption of Cd(II) and Pb(II) ions on selective paddy soil studied using batch experiments, over a wide concentration range, indicates that the Langmuir adsorption isotherm model is obeyed at low initial metal ion concentrations while the Freundlich adsorption isotherm model obeys at high metal ion concentrations in the presence and absence of glyphosate. For all cases, adsorption of both Cd(II) and Pb(II) ions obeys pseudo second order kinetics, suggesting that initial adsorption is a chemisorption process. In the presence of glyphosate formulation, the extent of adsorption of Cd(II) and Pb(II) ions on soil is decreased, while their desorption is increased at high concentrations of glyphosate. Low concentrations of glyphosate formulation do not significantly affect the desorption of metal ions from soil. Reduction of adsorption leads to enhance the concentration of Cd(II) and Pb(II) ions in the aqueous phase when in contact with soil. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Synthesis and characterization of chromium(III), manganese(II), iron(III), cobalt(II), nickel(II), copper(II), cadmium(II) and dioxouranium(VI) complexes of 4(2-pyridyl)-1-(2,4-dihydroxybenzaldehyde)-3-thiosemicarbazone

    International Nuclear Information System (INIS)

    Abu El-Reash, G.M.; Ibrahim, M.M.; Kenawy; El-Ayaan, Usama; Khattab, M.A.

    1994-01-01

    A few complexes of Cr(III), Mn(II), Fe(III), Co(II), Ni(II), Cu(II), Zn(II), Cd(II) and dioxouranium(VI) with 4(2-pyridyl)-1-(2,4-dihydroxybenzaldehyde)-3-thiosemicarbazone have been synthesised and characterized on the basis of elemental analysis, IR, electronic NMR, and magnetic moment data. An octahedral structure is proposed for the Cr(III), Fe(III), Co(II) and Ni(H 3 PBT) 2 Cl 2 .2H 2 O complexes; a tetrahedral structure for the Mn(II) and Ni 2 (PBT)OAc.H 2 0 complexes and a square planar structure for the Cu(II) complexes. The antimicrobial and antifungal activities of H 3 PBT and of its metal(II) complexes are investigated. The results reveal that H 3 PBT exhibits greater antimicrobial activities than its complexes. (author). 34 refs., 4 figs., 2 tabs

  10. Application and analysis of palladium vapor deposited on stainless steel for high temperature electrical contacts

    International Nuclear Information System (INIS)

    Jodeh, S.

    2008-01-01

    Using electron beam evaporation. Pd thin films of 300 nm thickness have been deposited on 301 stainless steel for high temperature electrical contact studies. The structure and compost ion of the helms were studied in detail x-ray diffraction (XRD), scanning electron microscopy (Sem), electron probe microanalysis (EPMA), and x-ray photoelectron spectroscopy (XP S) with sputter depth profiling. The contact properties such as contact resistance, fretting wear resistance, and thermal stability have been measured.The contact resistance rem ins low after heat-aging in air for 168 h at 150 and 200 deg., but increases significantly after heat-aging at 340 deg.. This increase in contact resistance is caused by the formation of about a 27 nm (1 μin.) thick Pdo. In contrast, the thickness of the Pdo is too thin to cause measurable contact resistance increases after heat-aging at 150 and 200 deg.. The fretting wear resistance of Pd coated 301 stainless steel is better than that of electroplated Sn of ser veal thousand nm thickness. Thus, vapor deposited Pd coating on 301 stainless steel may replace electroplated Sn for electrical contact application at elevated temperatures.

  11. Macroscopic and microscopic investigation of Ni(II) sequestration on diatomite by batch, XPS, and EXAFS techniques.

    Science.gov (United States)

    Sheng, Guodong; Yang, Shitong; Sheng, Jiang; Hu, Jun; Tan, Xiaoli; Wang, Xiangke

    2011-09-15

    Sequestration of Ni(II) on diatomite as a function of time, pH, and temperature was investigated by batch, XPS, and EXAFS techniques. The ionic strength-dependent sorption at pH < 7.0 was consistent with outer-sphere surface complexation, while the ionic strength-independent sorption at pH = 7.0-8.6 was indicative of inner-sphere surface complexation. EXAFS results indicated that the adsorbed Ni(II) consisted of ∼6 O at R(Ni-O) ≈ 2.05 Å. EXAFS analysis from the second shell suggested that three phenomena occurred at the diatomite/water interface: (1) outer-sphere and/or inner-sphere complexation; (2) dissolution of Si which is the rate limiting step during Ni uptake; and (3) extensive growth of surface (co)precipitates. Under acidic conditions, outer-sphere complexation is the main mechanism controlling Ni uptake, which is in good agreement with the macroscopic results. At contact time of 1 h or 1 day or pH = 7.0-8.0, surface coprecipitates occur concurrently with inner-sphere complexes on diatomite surface, whereas at contact time of 1 month or pH = 10.0, surface (co)precipitates dominate Ni uptake. Furthermore, surface loading increases with temperature increasing, and surface coprecipitates become the dominant mechanism at elevated temperature. The results are important to understand Ni interaction with minerals at the solid-water interface, which is helpful to evaluate the mobility of Ni(II) in the natural environment.

  12. pressure analysis and fluid contact prediction for alpha reservoir

    African Journals Online (AJOL)

    HOD

    a pressure gradient profile such that the oil gradient line will intersect the hydrostatic line above the Water-Up-To. (WUT) line to define the OWC if present. The model was also calibrated with data from reservoirs with established contacts in the field. 3. RESULTS AND DISCUSSION. In the field, pressure typically increases ...

  13. Microstructural analysis of the type-II boundary region in Alloy 152 weld

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seung Chang; Choi, Kyoung Joon; Kim, Ji Hyun [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2014-10-15

    The weld metals are more susceptible to SCC growth and that most cracks are blunted by the fusion boundary. However, they also found that some cracking occurs along the fusion boundary, often in an area with high hardness. Nelson et al. investigated a DMW of Monel 409 stainless steel and American Iron and Steel Institute (AISI) 1080 alloy and found a type-II boundary, which exists parallel to the fusion boundary in the dilution zone. They conclude that the type-II boundary is a potential path for crack growth. While there are several theories for the mechanisms of the type-II boundary formation, they conclude that the type-II boundary forms from the allotropic δ-γ transformation at the base metal in the elevated austenitic temperature range. As the operation time of nuclear power plants using DMWs of Alloy 152 and A533 Gr. B increases, these DMWs must be evaluated for their resistance to SCC for long-term operations. However, only few studies have investigated the thermal aging effects induced by long-term operations at high temperature. Type-II boundary is known as a potential crack path from the results of crack growth test at DMW without any heat treatment. So the analysis about type-II boundary with applying heat treatment could be helpful to evaluate the susceptibility to SCC of structural materials. The objective of this study is to analyze the detailed microstructure of the type-II boundary region in the DMW of Alloy 152 and A533 Gr. B, after applying heat treatment simulating thermal aging effect of a nuclear power plant operation condition to evaluate the susceptibility of this region to SCC. The microstructure of the type-II boundary region in the DMW of Alloy 152 and A533 Gr. B were analyzed with an energy dispersive x-ray spectroscope attached to a scanning electron microscope (SEM-EDS), electron backscatter diffraction (EBSD), and a nanoindentation test. Microstructural, grain boundary orientation, nanohardness analysis were conducted in the type-II

  14. Microstructural analysis of the type-II boundary region in Alloy 152 weld

    International Nuclear Information System (INIS)

    Yoo, Seung Chang; Choi, Kyoung Joon; Kim, Ji Hyun

    2014-01-01

    The weld metals are more susceptible to SCC growth and that most cracks are blunted by the fusion boundary. However, they also found that some cracking occurs along the fusion boundary, often in an area with high hardness. Nelson et al. investigated a DMW of Monel 409 stainless steel and American Iron and Steel Institute (AISI) 1080 alloy and found a type-II boundary, which exists parallel to the fusion boundary in the dilution zone. They conclude that the type-II boundary is a potential path for crack growth. While there are several theories for the mechanisms of the type-II boundary formation, they conclude that the type-II boundary forms from the allotropic δ-γ transformation at the base metal in the elevated austenitic temperature range. As the operation time of nuclear power plants using DMWs of Alloy 152 and A533 Gr. B increases, these DMWs must be evaluated for their resistance to SCC for long-term operations. However, only few studies have investigated the thermal aging effects induced by long-term operations at high temperature. Type-II boundary is known as a potential crack path from the results of crack growth test at DMW without any heat treatment. So the analysis about type-II boundary with applying heat treatment could be helpful to evaluate the susceptibility to SCC of structural materials. The objective of this study is to analyze the detailed microstructure of the type-II boundary region in the DMW of Alloy 152 and A533 Gr. B, after applying heat treatment simulating thermal aging effect of a nuclear power plant operation condition to evaluate the susceptibility of this region to SCC. The microstructure of the type-II boundary region in the DMW of Alloy 152 and A533 Gr. B were analyzed with an energy dispersive x-ray spectroscope attached to a scanning electron microscope (SEM-EDS), electron backscatter diffraction (EBSD), and a nanoindentation test. Microstructural, grain boundary orientation, nanohardness analysis were conducted in the type-II

  15. Systemic contact dermatitis after oral exposure to nickel

    DEFF Research Database (Denmark)

    Jensen, Christian Stab; Menné, Torkil; Johansen, Jeanne Duus

    2006-01-01

    Systemic contact dermatitis can be elicited experimentally in nickel-sensitive individuals by oral nickel exposure. A crucial point interpreting such experiments has been the relevance of nickel exposure from drinking water and diet. The aim of this meta-analysis study on former nickel......-exposure investigations was to provide the best possible estimation of threshold values of nickel doses that may cause systemic contact dermatitis in nickel-sensitive patients. 17 relevant investigations were identified, and statistical analyses were performed in a stepwise procedure. 9 studies were included in the final...... of the doses that, theoretically, would cause systemic contact dermatitis in exposed nickel-sensitive patients. The results from the 2 most sensitive groups show that 1% of these individuals may react with systemic contact dermatitis at normal daily nickel exposure from drinking water and diet, i.e. 0...

  16. Catalase-like activity studies of the manganese(II) adsorbed zeolites

    Science.gov (United States)

    Ćiçek, Ekrem; Dede, Bülent

    2013-12-01

    Preparation of manganese(II) adsorbed on zeolite 3A, 4A, 5A. AW-300, ammonium Y zeolite, organophilic, molecular sieve and catalase-like enzyme activity of manganese(II) adsorbed zeolites are reported herein. Firstly zeolites are activated at 873 K for two hours before contact manganese(II) ions. In order to observe amount of adsorption, filtration process applied for the solution. The pure zeolites and manganese(II) adsorbed zeolites were analysed by FT-IR. As a result according to the FT-IR spectra, the incorporation of manganese(II) cation into the zeolite structure causes changes in the spectra. These changes are expected particularly in the pseudolattice bands connected with the presence of alumino and silicooxygen tetrahedral rings in the zeolite structure. Furthermore, the catalytic activities of the Mn(II) adsorbed zeolites for the disproportionation of hydrogen peroxide were investigated in the presence of imidazole. The Mn(II) adsorbed zeolites display efficiency in the disproportion reactions of hydrogen peroxide, producing water and dioxygen in catalase-like activity.

  17. Level II scour analysis for Bridge 37 (TOWNTH00290037) on Town Highway 29, crossing Mill Brook, Townshend, Vermont

    Science.gov (United States)

    Burns, R.L.; Medalie, Laura

    1998-01-01

    This report provides the results of a detailed Level II analysis of scour potential at structure TOWNTH00290037 on Town Highway 29 crossing Mill Brook, Townshend, Vermont (figures 1–8). A Level II study is a basic engineering analysis of the site, including a quantitative analysis of stream stability and scour (FHWA, 1993). Results of a Level I scour investigation also are included in Appendix E of this report. A Level I investigation provides a qualitative geomorphic characterization of the study site. Information on the bridge, gleaned from Vermont Agency of Transportation (VTAOT) files, was compiled prior to conducting Level I and Level II analyses and is found in appendix D.

  18. Level II scour analysis for Bridge 8, (MANCTH00060008) on Town Highway 6, crossing Bourn Brook, Manchester, Vermont

    Science.gov (United States)

    Burns, Ronda L.; Hammond, Robert E.

    1997-01-01

    This report provides the results of a detailed Level II analysis of scour potential at structure MANCTH00060008 on Town Highway 6 crossing Bourn Brook, Manchester, Vermont (figures 1–8). A Level II study is a basic engineering analysis of the site, including a quantitative analysis of stream stability and scour (U.S. Department of Transportation, 1993). Results of a Level I scour investigation also are included in Appendix E of this report. A Level I investigation provides a qualitative geomorphic characterization of the study site. Information on the bridge, gleaned from Vermont Agency of Transportation (VTAOT) files, was compiled prior to conducting Level I and Level II analyses and is found in Appendix D.

  19. Level II scour analysis for Bridge 30, (HUNTTH00220030), on Town Highway 22, crossing Brush Brook, Huntington, Vermont

    Science.gov (United States)

    Burns, Ronda L.

    1997-01-01

    This report provides the results of a detailed Level II analysis of scour potential at structure HUNTTH00220030 on Town Highway 22 crossing Brush Brook, Huntington, Vermont (figures 1–8). A Level II study is a basic engineering analysis of the site, including a quantitative analysis of stream stability and scour (U.S. Department of Transportation, 1993). Results of a Level I scour investigation also are included in Appendix E of this report. A Level I investigation provides a qualitative geomorphic characterization of the study site. Information on the bridge, gleaned from Vermont Agency of Transportation (VTAOT) files, was compiled prior to conducting Level I and Level II analyses and is found in Appendix D.

  20. Level II scour analysis for brigde 5 (STOCTH00360005) on Town Highway 36, crossing Stony Brook, Stockridge, Vermont

    Science.gov (United States)

    Striker, Lora K.; Weber, Matthew A.

    1998-01-01

    This report provides the results of a detailed Level II analysis of scour potential at structure STOCTH00360005 on Town Highway 36 crossing Stony Brook, Stockbridge, Vermont (figures 1–8). A Level II study is a basic engineering analysis of the site, including a quantitative analysis of stream stability and scour (U.S. Department of Transportation, 1993). Results of a Level I scour investigation also are included in appendix E of this report. A Level I investigation provides a qualitative geomorphic characterization of the study site. Information on the bridge, gleaned from Vermont Agency of Transportation (VTAOT) files, was compiled prior to conducting Level I and Level II analyses and is found in appendix D.

  1. Level II scour analysis for Bridge 8 (ATHETH00090008) on Town Highway 9, crossing Bull Creek, Athens, Vermont

    Science.gov (United States)

    Boehmler, Erick M.; Burns, Ronda L.

    1997-01-01

    This report provides the results of a detailed Level II analysis of scour potential at structure ATHETH00090008 on Town Highway 9 crossing Bull Creek in Athens, Vermont (figures 1–8). A Level II study is a basic engineering analysis of the site, including a quantitative analysis of stream stability and scour (U.S. Department of Transportation, 1993). Results of a Level I scour investigation also are included in Appendix E of this report. A Level I investigation provides a qualitative geomorphic characterization of the study site. Information on the bridge, gleaned from Vermont Agency of Transportation (VTAOT) files, was compiled prior to conducting Level I and Level II analyses and is found in Appendix D.

  2. Level II scour analysis for Bridge 16, (NEWBTH00500016) on Town Highway 50, crossing Halls Brook, Newbury, Vermont

    Science.gov (United States)

    Burns, Ronda L.; Degnan, James R.

    1997-01-01

    This report provides the results of a detailed Level II analysis of scour potential at structure NEWBTH00500016 on Town Highway 50 crossing Halls Brook, Newbury, Vermont (figures 1–8). A Level II study is a basic engineering analysis of the site, including a quantitative analysis of stream stability and scour (U.S. Department of Transportation, 1993). Results of a Level I scour investigation also are included in Appendix E of this report. A Level I investigation provides a qualitative geomorphic characterization of the study site. Information on the bridge, gleaned from Vermont Agency of Transportation (VTAOT) files, was compiled prior to conducting Level I and Level II analyses and is found in Appendix D.

  3. Performances on nuclear activation analysis by TRIGA Mark II reactor

    International Nuclear Information System (INIS)

    Capannesi, G.; Rosada, A.

    1986-01-01

    Progresses in methodological research and connected applications in the field of activation analysis are introduced. Some peculiar characteristics on the TRIGA MARK II reactor have enabled the possibility of obtaining interesting results. The particular, the rotating radiation device Lazy Susan, with a capability of 40 positionings, permits homogeneity in neutron flux and energy spectrum stability within 15%. High level of precision and accuracy are obtained in analytic. Applications of major interest have been: - reference material certification; - forensic applications; - electrolytic cell productivity evaluation. The TRIGA MARK II reactor is equipped with a thermal column throughout a D 2 O diaphragm with a thickness of 70 cm. The available neutron flux has no fast and epithermal components. Via this facility a method has been tested for the instrumental determination of Al in Si metal of solar and electronic degree. (author)

  4. A thermoelectric power generating heat exchanger: Part II – Numerical modeling and optimization

    DEFF Research Database (Denmark)

    Sarhadi, Ali; Bjørk, Rasmus; Lindeburg, N.

    2016-01-01

    In Part I of this study, the performance of an experimental integrated thermoelectric generator (TEG)-heat exchanger was presented. In the current study, Part II, the obtained experimental results are compared with those predicted by a finite element (FE) model. In the simulation of the integrated...... TEG-heat exchanger, the thermal contact resistance between the TEG and the heat exchanger is modeled assuming either an ideal thermal contact or using a combined Cooper–Mikic–Yovanovich (CMY) and parallel plate gap formulation, which takes into account the contact pressure, roughness and hardness...

  5. Comparing maximum intercuspal contacts of virtual dental patients and mounted dental casts.

    Science.gov (United States)

    Delong, Ralph; Ko, Ching-Chang; Anderson, Gary C; Hodges, James S; Douglas, W H

    2002-12-01

    Quantitative measures of occlusal contacts are of paramount importance in the study of chewing dysfunction. A tool is needed to identify and quantify occlusal parameters without occlusal interference caused by the technique of analysis. This laboratory simulation study compared occlusal contacts constructed from 3-dimensional images of dental casts and interocclusal records with contacts found by use of conventional methods. Dental casts of 10 completely dentate adults were mounted in a semi-adjustable Denar articulator. Maximum intercuspal contacts were marked on the casts using red film. Intercuspal records made with an experimental vinyl polysiloxane impression material recorded maximum intercuspation. Three-dimensional virtual models of the casts and interocclusal records were made using custom software and an optical scanner. Contacts were calculated between virtual casts aligned manually (CM), aligned with interocclusal records scanned seated on the mandibular casts (C1) or scanned independently (C2), and directly from virtual interocclusal records (IR). Sensitivity and specificity calculations used the marked contacts as the standard. Contact parameters were compared between method pairs. Statistical comparisons used analysis of variance and the Tukey-Kramer post hoc test (P= CM/C1 = CM/C2 > C2/IR > CM/IR > C1/IR, where ">" means "closer than." Within the limits of this study, occlusal contacts calculated from aligned virtual casts accurately reproduce articulator contacts.

  6. Melanie II--a third-generation software package for analysis of two-dimensional electrophoresis images: II. Algorithms.

    Science.gov (United States)

    Appel, R D; Vargas, J R; Palagi, P M; Walther, D; Hochstrasser, D F

    1997-12-01

    After two generations of software systems for the analysis of two-dimensional electrophoresis (2-DE) images, a third generation of such software packages has recently emerged that combines state-of-the-art graphical user interfaces with comprehensive spot data analysis capabilities. A key characteristic common to most of these software packages is that many of their tools are implementations of algorithms that resulted from research areas such as image processing, vision, artificial intelligence or machine learning. This article presents the main algorithms implemented in the Melanie II 2-D PAGE software package. The applications of these algorithms, embodied as the feature of the program, are explained in an accompanying article (R. D. Appel et al.; Electrophoresis 1997, 18, 2724-2734).

  7. Dynamic Behavior Analysis of Non-Contacting Hydrodynamic Finger Seal Based on Fluid-Solid-Interaction Method

    Directory of Open Access Journals (Sweden)

    Su Hua

    2018-01-01

    Full Text Available Finger seal is an advanced compliant seal and can be utilized to separate high (HP and low pressure (LP zones in high speed rotating shaft environment. The work to be presented concerns the dynamic behavior of a repetitive section of a two-layer finger seal with high-and padded low-pressure laminates. The dynamic performance of the finger seal are analyzed by the coupled fluid-solid-interaction (FSI simulations. By using the commercial software ANSYS-CFX, the numerical simulation results of interactions between the gas flow and fingers structural deformation are described when the radial periodic excitation from the shaft applies to the finger seal. And the gas film loading capacity, gas film stiffness and leakage varied with time are put forward in different working conditions. Compared with the dynamic performance analysis results based on equivalent dynamic method, the FSI dynamic analysis shows some different characteristics which are more accordance with actual circumstance. Moreover, it is shown that under low pressure differential and high rotation speed the non-contacting finger seal with advance features both in sealing effectiveness and potential unlimited life span can be obtained by rational structure design. But for the non-contacting finger seal with circumferential convergent pad working in high pressure and low rotating speed conditions, it is difficult to improve the sealing performance by the way of changing the structure parameters of finger seal. It is because the high pressure plays a major role on this sealing situation.

  8. Contact isotopic- and contact ion-exchange between two adsorbents

    International Nuclear Information System (INIS)

    Bunzl, K.; Mohan, R.; Haimerl, M.

    1975-01-01

    The kinetics of contact ion exchange processes between an ion exchange membrane and resin ion exchange beads, stirred in pure water, was investigated. A general criterion was derived, which indicates whether diffusion of the ions between the intermingling electric double layers or the collision frequency between the two adsorbents is the rate dermining step. Since the latter process proved to be rate controlling under our experimental conditions, the corresponding rate equations were derived under various initial and boundary conditions. Experimentally, the kinetics of contact isotopic exchange of Cs + - and Na + -ions as well as of the reverse contact ion exchange process of Cs + -versus Na + -ions were investigated by using Na 22 and Cs 137 radioisotopes. The experiments reveal in quantitative accord with the theory that the rate of collision controlled contact ion exchange processes depends mainly on the 'exchange coefficient', the separation factor and the collision frequency. While the latter two quantities were determined independently by separate experiments, the 'exchange coefficient' was evaluated from a contact isotopic exchange experiment. (orig.) [de

  9. Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis.

    Science.gov (United States)

    Koppes, Sjors A; Engebretsen, Kristiane A; Agner, Tove; Angelova-Fischer, Irena; Berents, Teresa; Brandner, Johanna; Brans, Richard; Clausen, Maja-Lisa; Hummler, Edith; Jakasa, Ivone; Jurakić-Tončic, Ružica; John, Swen M; Khnykin, Denis; Molin, Sonja; Holm, Jan O; Suomela, Sari; Thierse, Hermann-Josef; Kezic, Sanja; Martin, Stefan F; Thyssen, Jacob P

    2017-07-01

    Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant and atopic dermatitis. Several studies have examined the pathogenesis and severity of allergic contact dermatitis by measuring the absence or presence of various biomarkers. In this review, we provide a non-systematic overview of biomarkers that have been studied in allergic contact dermatitis. These include genetic variations and mutations, inflammatory mediators, alarmins, proteases, immunoproteomics, lipids, natural moisturizing factors, tight junctions, and antimicrobial peptides. We conclude that, despite the enormous amount of data, convincing specific biomarkers for allergic contact dermatitis are yet to be described. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Quaternionic contact Einstein structures and the quaternionic contact Yamabe problem

    CERN Document Server

    Ivanov, Stefan; Vassilev, Dimiter

    2014-01-01

    A partial solution of the quaternionic contact Yamabe problem on the quaternionic sphere is given. It is shown that the torsion of the Biquard connection vanishes exactly when the trace-free part of the horizontal Ricci tensor of the Biquard connection is zero and this occurs precisely on 3-Sasakian manifolds. All conformal transformations sending the standard flat torsion-free quaternionic contact structure on the quaternionic Heisenberg group to a quaternionic contact structure with vanishing torsion of the Biquard connection are explicitly described. A "3-Hamiltonian form" of infinitesimal conformal automorphisms of quaternionic contact structures is presented.

  11. Effective removal of Ni(II) from aqueous solutions by modification of nano particles of clinoptilolite with dimethylglyoxime.

    Science.gov (United States)

    Nezamzadeh-Ejhieh, Alireza; Kabiri-Samani, Mehdi

    2013-09-15

    In this work an Iranian natural clinoptilolite tuff was pre-treated and changed to the micro (MCP) and nano (NCP) particles by mechanical method. Modification of micro and nano particles and also their Ni-exchanged forms were done by dimethylglyoxime (DMG). The raw and modified samples were characterized by XRD, FT-IR, SEM, BET, TG-DTG and energy dispersive analysis X-ray spectroscopy (EDAX). Removal of Ni(II) by modified and unmodified samples was investigated in batch procedure. It was found that NCP-DMG has higher capacity for removal of Ni(II). The effects of analytical parameters such as pH, dose of DMG, concentration of nickel solution, contact time and selectivity were studied and the optimal operation parameters were found as follows: pHPZC: 7.6, CNi(II): 0.01 M, contact time: 360 min and DMG dosage: 5mM. The results of selectivity experiments showed that the modified zeolite has a good selectivity for nickel in the presence of different multivalent cations. Langmuir and Freundlich isotherm models were adopted to describe the adsorption isotherms. Adsorption isotherms of Ni(II) ions could be best modelled by Langmuir equation, that indicate the monolayer sorption of Ni(II). Comparison of two kinetic models indicates that the adsorption kinetic can be well described by the pseudo-second-order rate equation that indicates that the rate limiting step for the process involves chemical reaction. The negative ΔH and ΔG indicate an exothermic and spontaneously process. The negative ΔS indicates that the adsorption of nickel cations from solution occurs with lower amount ion replacement, thus chemisorptions due to complex formation are dominant process in nickel removal. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Contact Dermatitis in Pediatrics.

    Science.gov (United States)

    Pelletier, Janice L; Perez, Caroline; Jacob, Sharon E

    2016-08-01

    Contact dermatitis is an umbrella term that describes the skin's reaction to contacted noxious or allergenic substances. The two main categories of contact dermatitis are irritant type and allergic type. This review discusses the signs, symptoms, causes, and complications of contact dermatitis. It addresses the testing, treatment, and prevention of contact dermatitis. Proper management of contact dermatitis includes avoidance measures for susceptible children. Implementation of a nickel directive (regulating the use of nickel in jewelry and other products that come into contact with the skin) could further reduce exposure to the most common allergens in the pediatric population. [Pediatr Ann. 2016;45(8):e287-e292.]. Copyright 2016, SLACK Incorporated.

  13. GLOBULAR CLUSTER ABUNDANCES FROM HIGH-RESOLUTION, INTEGRATED-LIGHT SPECTROSCOPY. II. EXPANDING THE METALLICITY RANGE FOR OLD CLUSTERS AND UPDATED ANALYSIS TECHNIQUES

    Energy Technology Data Exchange (ETDEWEB)

    Colucci, Janet E.; Bernstein, Rebecca A.; McWilliam, Andrew [The Observatories of the Carnegie Institution for Science, 813 Santa Barbara St., Pasadena, CA 91101 (United States)

    2017-01-10

    We present abundances of globular clusters (GCs) in the Milky Way and Fornax from integrated-light (IL) spectra. Our goal is to evaluate the consistency of the IL analysis relative to standard abundance analysis for individual stars in those same clusters. This sample includes an updated analysis of seven clusters from our previous publications and results for five new clusters that expand the metallicity range over which our technique has been tested. We find that the [Fe/H] measured from IL spectra agrees to ∼0.1 dex for GCs with metallicities as high as [Fe/H] = −0.3, but the abundances measured for more metal-rich clusters may be underestimated. In addition we systematically evaluate the accuracy of abundance ratios, [X/Fe], for Na i, Mg i, Al i, Si i, Ca i, Ti i, Ti ii, Sc ii, V i, Cr i, Mn i, Co i, Ni i, Cu i, Y ii, Zr i, Ba ii, La ii, Nd ii, and Eu ii. The elements for which the IL analysis gives results that are most similar to analysis of individual stellar spectra are Fe i, Ca i, Si i, Ni i, and Ba ii. The elements that show the greatest differences include Mg i and Zr i. Some elements show good agreement only over a limited range in metallicity. More stellar abundance data in these clusters would enable more complete evaluation of the IL results for other important elements.

  14. Sliding contact loading enhances the tensile properties of mesenchymal stem cell-seeded hydrogels

    Directory of Open Access Journals (Sweden)

    AH Huang

    2012-07-01

    Full Text Available The primary goal of cartilage tissue engineering is to recapitulate the functional properties and structural features of native articular cartilage. While there has been some success in generating near-native compressive properties, the tensile properties of cell-seeded constructs remain poor, and key features of cartilage, including inhomogeneity and anisotropy, are generally absent in these engineered constructs. Therefore, in an attempt to instill these hallmark properties of cartilage in engineered cell-seeded constructs, we designed and characterized a novel sliding contact bioreactor to recapitulate the mechanical stimuli arising from physiologic joint loading (two contacting cartilage layers. Finite element modeling of this bioreactor system showed that tensile strains were direction-dependent, while both tensile strains and fluid motion were depth-dependent and highest in the region closest to the contact surface. Short-term sliding contact of mesenchymal stem cell (MSC-seeded agarose improved chondrogenic gene expression in a manner dependent on both the axial strain applied and transforming growth factor-β supplementation. Using the optimized loading parameters derived from these short-term studies, long-term sliding contact was applied to MSC-seeded agarose constructs for 21 d. After 21 d, sliding contact significantly improved the tensile properties of MSC-seeded constructs and elicited alterations in type II collagen and proteoglycan accumulation as a function of depth; staining for these matrix molecules showed intense localization in the surface regions. These findings point to the potential of sliding contact to produce engineered cartilage constructs that begin to recapitulate the complex mechanical features of the native tissue.

  15. Colony contact contributes to the diversity of gut bacteria in bumblebees (Bombus terrestris)

    Institute of Scientific and Technical Information of China (English)

    Annelies Billiet; Ivan Meeus; Filip Van Nieuwerburgh; Dieter Deforce; Felix W(a)ckers; Guy Smagghe

    2017-01-01

    Social bees,like honeybees and bumblebees,have a close contact with nest mates of different developmental stages and generations.This could enhance bacterial transfer between nest mates and offers opportunities for direct transfer of symbionts from one generation to the next,resulting in a stable host specific gut microbiota.Gut symbionts of honeybees and bumblebees have been suggested to contribute in digestion and protection against parasites and pathogens.Here we studied the impact of contact with the bumblebee colony on the colonization potential of the bacterial families (i.e.,Neisseriaceae,Orbaceae,Lactobacillaceae and Bifidobacteriaceae) occurring in the gut of adult bumblebees (Bombus terrestris).Bacterial profiles of the gut microbiota of B.terrestris were determined based on the hypervariable V4 region of the 16S rRNA using paired-end Illumina sequencing.In our experiments,we created different groups in which we gradually reduced the contact with nest mates and hive material.We made 3 observations:(i) reducing the contact between the colony and the bumblebee during adult life resulted in a significant drop in the relative abundance of Lactobacillus bombicola and Lactobacillus bombi;(ii) Bifidobacteriaceae required contact with nest mates to colonize the gut of B.terrestris and a significant lower bacterial diversity was observed in bumblebees that were completely excluded from colony contact during the adult life;(iii) Snodgrassella and Gilliamella were able to colonize the gut of the adult bumblebee without any direct contact with nest mates in the adult life stage.These results indicate the impact of the colony life on the diversity of the characteristic bumblebee gut bacteria.

  16. Contact lenses fitting after intracorneal ring segments implantation in keratoconus

    Directory of Open Access Journals (Sweden)

    Luciane Bugmann Moreira

    2013-08-01

    Full Text Available PURPOSE: Evaluate contact lenses fitting after intracorneal ring implantation for keratoconus, its visual acuity and comfort. METHODS: Retrospective study of patients undergoing contact lenses fitting, after intracorneal ring for keratoconus. The criterion for contact lens fitting was unsatisfactory visual acuity with spectacle correction as referred by the patients. All patients were intolerants to contact lenses prior to intracorneal implantation. Visual acuity analysis was done by conversion of Snellen to logMAR scales. The comfort was evaluated according subjective questioning of good, medium or poor comfort. RESULTS: Nineteen patients were included in the study. Two patients (10.5% did not achieved good comfort with contact lenses and underwent penetrating keratoplasties. All the others 17 patients showed good or medium comfort. Four rigid gas-permeable contact lenses were fitted, one piggyback approach, 3 toric soft contact lenses, 2 soft lenses specially design for keratoconus and 7 disposable soft lenses. The average visual acuity improved from 0.77 ± 0.37 to 0.19 ± 0.13 logMAR units after contact lenses fitting. CONCLUSION: Contact lens fitting after intracorneal ring is possible, provides good comfort, improves visual acuity, and therefore, may postpone the need for penetrating keratoplasty.

  17. On Ni/Au Alloyed Contacts to Mg-Doped GaN

    Science.gov (United States)

    Sarkar, Biplab; Reddy, Pramod; Klump, Andrew; Kaess, Felix; Rounds, Robert; Kirste, Ronny; Mita, Seiji; Kohn, Erhard; Collazo, Ramon; Sitar, Zlatko

    2018-01-01

    Ni/Au contacts to p-GaN were studied as a function of free hole concentration in GaN using planar transmission line measurement structures. All contacts showed a nonlinear behavior, which became stronger for lower doping concentrations. Electrical and structural analysis indicated that the current conduction between the contact and the p-GaN was through localized nano-sized clusters. Thus, the non-linear contact behavior can be well explained using the alloyed contact model. Two contributions to the contact resistance were identified: the spreading resistance in the semiconductor developed by the current crowding around the electrically active clusters, and diode-type behavior at the interface of the electrically active clusters with the semiconductor. Hence, the equivalent Ni/Au contact model consists of a diode and a resistor in series for each active cluster. The reduced barrier height observed in the measurements is thought to be generated by the extraction of Ga from the crystalline surface and localized formation of the Au:Ga phase. The alloyed contact analyses presented in this work are in good agreement with some of the commonly observed behavior of similar contacts described in the literature.

  18. Mean field theory of epidemic spreading with effective contacts on networks

    International Nuclear Information System (INIS)

    Wu, Qingchu; Chen, Shufang

    2015-01-01

    We present a general approach to the analysis of the susceptible-infected-susceptible model with effective contacts on networks, where each susceptible node will be infected with a certain probability only for effective contacts. In the network, each node has a given effective contact number. By using the one-vertex heterogenous mean-field (HMF) approximation and the pair HMF approximation, we obtain conditions for epidemic outbreak on degree-uncorrelated networks. Our results suggest that the epidemic threshold is closely related to the effective contact and its distribution. However, when the effective contact is only dependent of node degree, the epidemic threshold can be established by the degree distribution of networks.

  19. What Governs Friction of Silicon Oxide in Humid Environment: Contact Area between Solids, Water Meniscus around the Contact, or Water Layer Structure?

    Science.gov (United States)

    Chen, Lei; Xiao, Chen; Yu, Bingjun; Kim, Seong H; Qian, Linmao

    2017-09-26

    In order to understand the interfacial parameters governing the friction force (F t ) between silicon oxide surfaces in humid environment, the sliding speed (v) and relative humidity (RH) dependences of F t were measured for a silica sphere (1 μm radius) sliding on a silicon oxide (SiO x ) surface, using atomic force microscopy (AFM), and analyzed with a mathematical model describing interfacial contacts under a dynamic condition. Generally, F t decreases logarithmically with increasing v to a cutoff value below which its dependence on interfacial chemistry and sliding condition is relatively weak. Above the cutoff value, the logarithmic v dependence could be divided into two regimes: (i) when RH is lower than 50%, F t is a function of both v and RH; (ii) in contrast, at RH ≥ 50%, F t is a function of v only, but not RH. These complicated v and RH dependences were hypothesized to originate from the structure of the water layer adsorbed on the surface and the water meniscus around the annulus of the contact area. This hypothesis was tested by analyzing F t as a function of the water meniscus area (A m ) and volume (V m ) estimated from a thermally activated water-bridge formation model. Surprisingly, it was found that F t varies linearly with V m and correlates poorly with A m at RH contact under ambient conditions.

  20. Automatic contact in DYNA3D for vehicle crashworthiness

    International Nuclear Information System (INIS)

    Whirley, R.G.; Engelmann, B.E.

    1994-01-01

    This paper presents a new formulation for the automatic definition and treatment of mechanical contact in explicit, nonlinear, finite element analysis. Automatic contact offers the benefits of significantly reduced model construction time and fewer opportunities for user error, but faces significant challenges in reliability and computational costs. The authors have used a new four-step automatic contact algorithm. Key aspects of the proposed method include (1) automatic identification of adjacent and opposite surfaces in the global search phase, and (2) the use of a smoothly varying surface normal that allows a consistent treatment of shell intersection and corner contact conditions without ad hoc rules. Three examples are given to illustrate the performance of the newly proposed algorithm in the public DYNA3D code

  1. Projecting social contact matrices in 152 countries using contact surveys and demographic data.

    Directory of Open Access Journals (Sweden)

    Kiesha Prem

    2017-09-01

    Full Text Available Heterogeneities in contact networks have a major effect in determining whether a pathogen can become epidemic or persist at endemic levels. Epidemic models that determine which interventions can successfully prevent an outbreak need to account for social structure and mixing patterns. Contact patterns vary across age and locations (e.g. home, work, and school, and including them as predictors in transmission dynamic models of pathogens that spread socially will improve the models' realism. Data from population-based contact diaries in eight European countries from the POLYMOD study were projected to 144 other countries using a Bayesian hierarchical model that estimated the proclivity of age-and-location-specific contact patterns for the countries, using Markov chain Monte Carlo simulation. Household level data from the Demographic and Health Surveys for nine lower-income countries and socio-demographic factors from several on-line databases for 152 countries were used to quantify similarity of countries to estimate contact patterns in the home, work, school and other locations for countries for which no contact data are available, accounting for demographic structure, household structure where known, and a variety of metrics including workforce participation and school enrolment. Contacts are highly assortative with age across all countries considered, but pronounced regional differences in the age-specific contacts at home were noticeable, with more inter-generational contacts in Asian countries than in other settings. Moreover, there were variations in contact patterns by location, with work-place contacts being least assortative. These variations led to differences in the effect of social distancing measures in an age structured epidemic model. Contacts have an important role in transmission dynamic models that use contact rates to characterize the spread of contact-transmissible diseases. This study provides estimates of mixing patterns for

  2. Projecting social contact matrices in 152 countries using contact surveys and demographic data.

    Science.gov (United States)

    Prem, Kiesha; Cook, Alex R; Jit, Mark

    2017-09-01

    Heterogeneities in contact networks have a major effect in determining whether a pathogen can become epidemic or persist at endemic levels. Epidemic models that determine which interventions can successfully prevent an outbreak need to account for social structure and mixing patterns. Contact patterns vary across age and locations (e.g. home, work, and school), and including them as predictors in transmission dynamic models of pathogens that spread socially will improve the models' realism. Data from population-based contact diaries in eight European countries from the POLYMOD study were projected to 144 other countries using a Bayesian hierarchical model that estimated the proclivity of age-and-location-specific contact patterns for the countries, using Markov chain Monte Carlo simulation. Household level data from the Demographic and Health Surveys for nine lower-income countries and socio-demographic factors from several on-line databases for 152 countries were used to quantify similarity of countries to estimate contact patterns in the home, work, school and other locations for countries for which no contact data are available, accounting for demographic structure, household structure where known, and a variety of metrics including workforce participation and school enrolment. Contacts are highly assortative with age across all countries considered, but pronounced regional differences in the age-specific contacts at home were noticeable, with more inter-generational contacts in Asian countries than in other settings. Moreover, there were variations in contact patterns by location, with work-place contacts being least assortative. These variations led to differences in the effect of social distancing measures in an age structured epidemic model. Contacts have an important role in transmission dynamic models that use contact rates to characterize the spread of contact-transmissible diseases. This study provides estimates of mixing patterns for societies for which

  3. Adsorption of platinum(IV) and palladium(II) from aqueous solution by thiourea-modified chitosan microspheres

    International Nuclear Information System (INIS)

    Zhou Limin; Liu Jinhui; Liu Zhirong

    2009-01-01

    The chitosan microparticles were prepared using the inverse phase emulsion dispersion method and modified with thiourea (TCS). TCS was characterized by scanning electron microscope (SEM), the Fourier transform infrared (FT-IR) spectra, sulfur elemental analysis, specific surface area and pore diameter. The effects of various parameters, such as pH, contact time, initial concentration and temperature, on the adsorption of Pt(IV) and Pd(II) by TCS were investigated. The results showed that the maximum adsorption capacity was found at pH 2.0 for both Pt(IV) and Pd(II). TCS can selectively adsorb Pt(IV) and Pd(II) from binary mixtures with Cu(II), Pb(II), Cd(II), Zn(II), Ca(II), and Mg(II). The adsorption reaction followed the pseudo-second-order kinetics, indicating the main adsorption mechanism of chemical adsorption. The isotherm adsorption equilibrium was well described by Langmuir isotherms with the maximum adsorption capacity of 129.9 mg/g for Pt(IV) and 112.4 mg/g for Pd(II). The adsorption capacity of both Pt(IV) and Pd(II) decreased with temperature increasing. The negative values of enthalpy (ΔH o ) and Gibbs free energy (ΔG o ) indicate that the adsorption process is exothermic and spontaneous in nature. The adsorbent was stable without loss of the adsorption capacity up to at least 5 cycles and the desorption efficiencies were above 95% when 0.5 M EDTA-0.5 M H 2 SO 4 eluent was used. The results also showed that the preconcentration factor for Pt(IV) and Pd(II) was 196 and 172, respectively, and the recovery was found to be more than 97% for both precious metal ions.

  4. Contact angle control of sessile drops on a tensioned web

    Science.gov (United States)

    Park, Janghoon; Kim, Dongguk; Lee, Changwoo

    2018-04-01

    In this study, the influence of the change of tension applied to flexible and thin web substrate on the contact angle of sessile drop in roll-to-roll system was investigated. Graphene oxide and deionized water solutions were used in the experiments. Tension was changed to 29, 49, and 69 N, and the casting distance of the micropipette and the material was set to 10, 20, and 40 mm, and the droplet volume was set to 10, 20, and 30 μL, respectively. Statistical analysis of three variables and analysis of the variance methodology showed that the casting distance was most significant for the contact angle change, and the most interesting tension variable was also affected. The change in tension caused the maximum contact angle to change by 5.5°. The tension was not uniform in the width direction. When the droplet was applied in the same direction in the width direction, it was confirmed that the tension unevenness had great influence on the contact angle up to 11°. Finally, the casting distance, which has a large effect on the contact angle, was calibrated in the width direction to reduce the width direction contact angle deviation to 1%. This study can be applied to fine patterning research using continuous inkjet printing and aerosol jet printing, which are roll-to-roll processes based on droplet handling.

  5. Contact allergy and allergic contact dermatitis in adolescents: prevalence measures and associations

    DEFF Research Database (Denmark)

    Mørtz, Charlotte G; Lauritsen, Jens Martin; Bindslev-Jensen, Carsten

    2002-01-01

    The aims of this cross-sectional study were to establish the prevalence measures of contact allergy and allergic contact dermatitis in 8th grade schoolchildren (aged 12-16 years) in Odense, Denmark, and to examine the associations with atopic dermatitis, inhalant allergy and hand eczema. Contact...... allergy to a standard series allergen was found in 15.2% of schoolchildren. The point prevalence of allergic contact dermatitis was 0.7% and the lifetime prevalence 7.2%, predominantly in girls. The most common contact allergens were nickel (8.6%) and fragrance mix (1.8%). Nickel allergy was clinically...... relevant in 69% and fragrance allergy in 29% of cases. A significant association was found between contact allergy and hand eczema while no association was found between contact allergy and atopic dermatitis or inhalant allergy. In the future this cohort of schoolchildren will be followed with regard...

  6. Preparation and Spectral Properties of Mixed-Ligand Complexes of VO(IV, Ni(II, Zn(II, Pd(II, Cd(II and Pb(II with Dimethylglyoxime and N-acetylglycine

    Directory of Open Access Journals (Sweden)

    Shayma A. Shaker

    2010-01-01

    Full Text Available A number of mixed-ligand complexes of the general formula [M(D(G] where D=dimethylglyoximato monoanion, G=N-acetylglycinato and M=VO(IV, Ni(II, Zn(II, Pd(II, Cd(II and Pb(II were prepared. Each complex was characterized by elemental analysis, determination of metal, infrared spectra, electronic spectra, (1H and 13C NMR spectra, conductivity and magnetic moments. All these complexes were not soluble in some of the organic solvent but highly soluble in dimethylformamide. The conductivity data showed the non-electrolytic nature of the complexes. The electronic spectra exhibited absorption bands in the visible region caused by the d-d electronic transition such as VO(IV, Ni(II and Pd(II. The IR and (1H, 13C NMR spectra which have indicate that the dimethylglyoxime was coordinated with the metal ions through the N and O atoms of the oxime group and N-acetylglycine was coordinated with metal ions through the N atom and terminal carboxyl oxygen atom.

  7. Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis

    NARCIS (Netherlands)

    Koppes, Sjors A.; Engebretsen, Kristiane A.; Agner, Tove; Angelova-Fischer, Irena; Berents, Teresa; Brandner, Johanna; Brans, Richard; Clausen, Maja-Lisa; Hummler, Edith; Jakasa, Ivone; Jurakić-Tončic, Ružica; John, Swen M.; Khnykin, Denis; Molin, Sonja; Holm, Jan O.; Suomela, Sari; Thierse, Hermann-Josef; Kezic, Sanja; Martin, Stefan F.; Thyssen, Jacob P.

    2017-01-01

    Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant and

  8. Relationship between the real contact area and contact force in pre-sliding regime

    International Nuclear Information System (INIS)

    Song Baojiang; Yan Shaoze

    2017-01-01

    The pre-sliding regime is typically neglected in the dynamic modelling of mechanical systems. However, the change in contact state caused by static friction may decrease positional accuracy and control precision. To investigate the relationship between contact status and contact force in pre-sliding friction, an optical experimental method is presented in this paper. With this method, the real contact state at the interface of a transparent material can be observed based on the total reflection principle of light by using an image processing technique. A novel setup, which includes a pair of rectangular trapezoidal blocks, is proposed to solve the challenging issue of accurately applying different tangential and normal forces to the contact interface. The improved Otsu’s method is used for measurement. Through an experimental study performed on polymethyl methacrylate (PMMA), the quantity of contact asperities is proven to be the dominant factor that affects the real contact area. The relationship between the real contact area and the contact force in the pre-sliding regime is studied, and the distribution of static friction at the contact interface is qualitatively discussed. New phenomena in which the real contact area expands along with increasing static friction are identified. The aforementioned relationship is approximately linear at the contact interface under a constant normal pressure, and the distribution of friction stress decreases from the leading edge to the trailing edge. (paper)

  9. Adsorption of Pb(II) ions present in aqueous solution on the oxy hydroxides: boehmite (γ-AIOOH), goethite (α-FeOOH) and manganite (γ-MnOOH); Adsorcion de iones Pb(II) presentes en solucion acuosa sobre los oxihidroxidos: boehmita (γ-AlOOH), goetita (α-FeOOH) y manganita (γ-MnOOH)

    Energy Technology Data Exchange (ETDEWEB)

    Arreola L, J. E.

    2013-07-01

    Boehmite, goethite and manganite were synthesized by different methods and characterized using X-ray diffraction (XRD), infrared spectroscopy (IR), thermogravimetric study , N{sub 2} physisorption measurements, scanning electron microscopy (Sem), semiquantitative elemental analysis (EDS), as well as additional studies were determined the surface active sites concentration and zero point of charge. Furthermore, we studied the Pb(II) ion adsorption capacity present in aqueous solution on these synthesized materials by batch-type experiments at room temperature, as a function of contact time between the phases liquid-solid system (adsorption kinetics), initial concentration of the adsorbate (adsorption isotherms), ph and temperature. The adsorption equilibrium time of adsorption processes in these studied systems was found at 60 minutes for boehmite and 30 minutes for goethite and manganite respectively after contacting the solid-liquid phase systems. The adsorption capacity of the lead ions on these adsorbent materials depended of lead concentration, ph and temperature of the systems. Were evaluated lead adsorption capacities in these materials to different contact times using an initial concentration of 20 mg/L of Pb(II) ions at ph = 4, the results of three systems were adjusted to second pseudo kinetic model order. With respect to the study of the adsorbate concentration effect, boehmite-Pb(II) and goethite-Pb(II) systems were adjusted to Langmuir isotherm model which proposes that the adsorption is carried out in a monolayer, moreover manganite-Pb(II) system was adjusted Temp kin isotherm model, which assumes that the adsorption heat of all the molecules in the layer decreases linearly with coverage due to adsorbent-adsorbate interactions and adsorption is characterized by a uniform distribution of the binding energies. Were studied the ph effect of Pb(II) ions solution on the adsorption capacity of such adsorbents, it was found that as the ph increases lead

  10. A cephalometric analysis of Class II dentate subjects to establish a formula to determine the occlusal plane in Class II edentate subjects: A neo adjunct.

    Science.gov (United States)

    Sinha, Nikita; Reddy, K Mahendranadh; Gupta, Nidhi; Shastry, Y M

    2017-01-01

    Occlusal plane (OP) differs considerably in participants with skeletal Class I and Class II participants. In this study, cephalometrics has been used to help in the determination of orientation of the OP utilizing the nonresorbable bony anatomic landmarks in skeletal Class II participants and an attempt has been made to predict and examine the OP in individuals with skeletal class II jaw relationship. One hundred dentulous participants with skeletal Class II malocclusion who came to the hospital for correcting their jaw relationship participated in the study. Their right lateral cephalogram was taken using standardized procedures, and all the tracings were manually done by a single trained examiner. The cephalograms which were taken for the diagnostic purpose were utilized for the study, and the patient was not exposed to any unnecessary radiation. The numerical values obtained from the cephalograms were subjected to statistical analysis. Pearson's correlation of orientation of the OP in Class II edentulous participants. Pearson's correlation coefficient and linear regression analysis were performed, and a high correlation was found between A2 and (A2 + B2)/(B2 + C2) with " r " value of 0.5. A medium correlation was found between D2 and (D2 + E2)/(E2 + F2) with " r " value of 0.42. The formula obtained for posterior reference frame through linear regression equation was y = 0.018* × +0.459 and the formula obtained for anterior reference frame was y1 = 0.011* × 1 + 0.497. It was hypothesized that by substituting these formulae in the cephalogram obtained from the Class II edentate individual, the OP can be obtained and verified. It was concluded that cephalometrics can be useful in examining the orientation of OP in skeletal Class II participants.

  11. Emodin (1,3,8-trihydroxy-6-methylanthraquinone): a spectrophotometric reagent for the determination of beryllium(II), magnesium(II) and calcium(II)

    International Nuclear Information System (INIS)

    Pal, T.; Jana, N.R.

    1993-01-01

    The individual determination of Be II , Mg II or Ca II by conventional spectrophotometry and simultaneous determination of Mg II and Ca II in mixtures by first-derivative spectrophotometry are possible at trace levels, using emodin (1,3,8-trihydroxy-6-methylanthraquinone) as spectrophotometric reagent. Interference from other metal species, application of these methods to rock samples and statistical analysis of the results are discussed. (author)

  12. Contact Lens Risks

    Science.gov (United States)

    ... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...

  13. Noneczematous Contact Dermatitis

    Science.gov (United States)

    Foti, Caterina; Vestita, Michelangelo; Angelini, Gianni

    2013-01-01

    Irritant or allergic contact dermatitis usually presents as an eczematous process, clinically characterized by erythematoedematovesicous lesions with intense itching in the acute phase. Such manifestations become erythematous-scaly as the condition progresses to the subacute phase and papular-hyperkeratotic in the chronic phase. Not infrequently, however, contact dermatitis presents with noneczematous features. The reasons underlying this clinical polymorphism lie in the different noxae and contact modalities, as well as in the individual susceptibility and the various targeted cutaneous structures. The most represented forms of non-eczematous contact dermatitis include the erythema multiforme-like, the purpuric, the lichenoid, and the pigmented kinds. These clinical entities must obviously be discerned from the corresponding “pure” dermatitis, which are not associated with contact with exogenous agents. PMID:24109520

  14. Study on the fatigue crack initiation life under spherical contact

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Joo; Kim, Tae Wan [Busan National Univ., Busan (Korea, Republic of); Lee, Mun Ju [Samsung Electronics Co., Ltd., Suwon (Korea, Republic of)

    2001-08-01

    In case of contact fatigue, the accurate calculation of surface tractions and subsurface stress is essential to the prediction of crack initiation life. Surface tractions influencing shear stress amplitude have been obtained by contact analysis based on influence function. Subsurface stress has been obtained by using rectangular patch solutions. In this study, to simulate asperity contact under sliding condition, the tip of asperity was simulated by sphere and to calculate crack initiation life in the substrate, dislocation pileup theory was used.

  15. Study on the fatigue crack initiation life under spherical contact

    International Nuclear Information System (INIS)

    Cho, Yong Joo; Kim, Tae Wan; Lee, Mun Ju

    2001-01-01

    In case of contact fatigue, the accurate calculation of surface tractions and subsurface stress is essential to the prediction of crack initiation life. Surface tractions influencing shear stress amplitude have been obtained by contact analysis based on influence function. Subsurface stress has been obtained by using rectangular patch solutions. In this study, to simulate asperity contact under sliding condition, the tip of asperity was simulated by sphere and to calculate crack initiation life in the substrate, dislocation pileup theory was used

  16. Synthesis, Spectroscopy, Thermal Analysis, Magnetic Properties and Biological Activity Studies of Cu(II and Co(II Complexes with Schiff Base Dye Ligands

    Directory of Open Access Journals (Sweden)

    Saeid Amani

    2012-05-01

    Full Text Available Three azo group-containing Schiff base ligands, namely 1-{3-[(3-hydroxy-propyliminomethyl]-4-hydroxyphenylazo}-4-nitrobenzene (2a, 1-{3-[(3-hydroxypropyl-iminomethyl]-4-hydroxyphenylazo}-2-chloro-4-nitrobenzene (2b and 1-{3-[(3-hydroxy-propyliminomethyl]-4-hydroxyphenylazo}-4-chloro-3-nitrobenzene (2c were prepared. The ligands were characterized by elemental analysis, FTIR spectroscopy, UV-Vis spectroscopy, 13C- and 1H-NMR spectroscopy and thermogravimetric analysis. Next the corresponding copper(II and cobalt(II metal complexes were synthesized and characterized by the physicochemical and spectroscopic methods of elemental analysis, FTIR spectroscopy, UV-Vis spectroscopy, magnetic moment measurements, and thermogravimetric analysis (TGA and (DSC. The room temperature effective magnetic moments of complexes are 1.45, 1.56, 1.62, 2.16, 2.26 and 2.80 B.M. for complexes 3a, 3b, 3c, 4a 4b, and 4c, respectively, indicating that the complexes are paramagnetic with considerable electronic communication between the two metal centers.

  17. Subclassification of Recursive Partitioning Analysis Class II Patients With Brain Metastases Treated Radiosurgically

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Masaaki, E-mail: BCD06275@nifty.com [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan); Department of Neurosurgery, Tokyo Women' s Medical University Medical Center East, Tokyo (Japan); Sato, Yasunori [Clinical Research Center, Chiba University Graduate School of Medicine, Chiba (Japan); Serizawa, Toru [Tokyo Gamma Unit Center, Tsukiji Neurologic Clinic, Tokyo (Japan); Kawabe, Takuya [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan); Department of Neurosurgery, Kyoto Prefectural University of Medicine Graduate School of Medical Sciences, Kyoto (Japan); Higuchi, Yoshinori [Department of Neurosurgery, Chiba University Graduate School of Medicine, Chiba (Japan); Nagano, Osamu [Gamma Knife House, Chiba Cardiovascular Center, Ichihara (Japan); Barfod, Bierta E. [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan); Ono, Junichi [Gamma Knife House, Chiba Cardiovascular Center, Ichihara (Japan); Kasuya, Hidetoshi [Department of Neurosurgery, Tokyo Women' s Medical University Medical Center East, Tokyo (Japan); Urakawa, Yoichi [Katsuta Hospital Mito GammaHouse, Hitachi-naka (Japan)

    2012-08-01

    Purpose: Although the recursive partitioning analysis (RPA) class is generally used for predicting survival periods of patients with brain metastases (METs), the majority of such patients are Class II and clinical factors vary quite widely within this category. This prompted us to divide RPA Class II patients into three subclasses. Methods and Materials: This was a two-institution, institutional review board-approved, retrospective cohort study using two databases: the Mito series (2,000 consecutive patients, comprising 787 women and 1,213 men; mean age, 65 years [range, 19-96 years]) and the Chiba series (1,753 patients, comprising 673 female and 1,080 male patients; mean age, 65 years [range, 7-94 years]). Both patient series underwent Gamma Knife radiosurgery alone, without whole-brain radiotherapy, for brain METs during the same 10-year period, July 1998 through June 2008. The Cox proportional hazard model with a step-wise selection procedure was used for multivariate analysis. Results: In the Mito series, four factors were identified as favoring longer survival: Karnofsky Performance Status (90% to 100% vs. 70% to 80%), tumor numbers (solitary vs. multiple), primary tumor status (controlled vs. not controlled), and non-brain METs (no vs. yes). This new index is the sum of scores (0 and 1) of these four factors: RPA Class II-a, score of 0 or 1; RPA Class II-b, score of 2; and RPA Class II-c, score of 3 or 4. Next, using the Chiba series, we tested whether our index is valid for a different patient group. This new system showed highly statistically significant differences among subclasses in both the Mito series and the Chiba series (p < 0.001 for all subclasses). In addition, this new index was confirmed to be applicable to Class II patients with four major primary tumor sites, that is, lung, breast, alimentary tract, and urogenital organs. Conclusions: Our new grading system should be considered when designing future clinical trials involving brain MET

  18. SIMMER-II analysis of transition-phase experiments

    International Nuclear Information System (INIS)

    Wehner, T.R.; Bell, C.R.

    1985-01-01

    Analyses of Los Alamos transition-phase experiments with the SIMMER-II computer code are reported. These transient boilup experiments simulated the recriticality-induced transient motion of a boiling pool of molten fuel, molten steel and steel vapor, within a subassembly duct in a liquid-metal fast breeder reactor during the transition phase of a core-disruptive accident. The two purposes of these experiments were to explore and reach a better understanding of fast reactor safety issues, and to provide data for SIMMER-II verification. Experimental data, consisting of four pressure traces and a high-speed movie, were recorded for four sets of initial conditions. For three of the four cases, SIMMER-II-calculated pressures compared reasonably well with the experimental pressures. After a modification to SIMMER-II's liquid-vapor drag correlation, the comparison for the fourth case was reasonable also. 12 refs., 4 figs

  19. Studies on Development of Polymeric Materials Using Gamma Irradiation for Contact and Intraocular Lenses

    Directory of Open Access Journals (Sweden)

    Pranshu Chhabra

    2009-01-01

    Full Text Available For the development of materials for contact lenses and intraocular lenses, the selection criteria is based on the (i capacity to absorb and retain water, (ii hydrophilicity and hydrophobicity, (iii refractive index and (iv hardness besides the other essential properties. Various monomers are being studied to develop suitable materials for such applications. Selection of suitable monomers that can be converted into optical materials of desired characteristics is the most essential step. In the present paper, an attempt has been made to develop suitable optical polymers based on 2-hydroxy ethyl methacrylate (HEMA, N-vinyl pyrrolidone (NVP, methyl methacrylate (MMA, methacrylic acid (MAA, and styrene. Compositions were prepared in such a way that polymers of varying hydrophilicity or hydrophobicity could be obtained keeping HEMA as the base (main monomer. For polymerization, gamma irradiation (Co-60 as a source was used. The results of the study showed that: (i an increase in NVP and MAA content brought in an increase in hydrophilicity of polymerized HEMA (pHEMA, while the addition of styrene and MMA decreased hydrophilicity of polymerized HEMA (pHEMA, (ii polymers for contact lenses with water retention capacity as high as >50 wt.% and as low as <10 wt% with varying content of suitable comonomers can be designed, (iii polymeric materials for contact lenses can be made by using radiation processing such as Co-60 and (iv a dose of 40 kGy was found to be ideal for purpose.

  20. Analysis of main parameters affecting substrate/mortar contact area through tridimensional laser scanner.

    Science.gov (United States)

    Stolz, Carina M; Masuero, Angela B

    2015-10-01

    This study assesses the influence of the granulometric composition of sand, application energy and the superficial tension of substrates on the contact area of rendering mortars. Three substrates with distinct wetting behaviors were selected and mortars were prepared with different sand compositions. Characterization tests were performed on fresh and hardened mortars, as well as the rheological characterization. Mortars were applied to substrates with two different energies. The interfacial area was then digitized with 3D scanner. Results show that variables are all of influence on the interfacial contact in the development area. Furthermore, 3D laser scanning proved to be a good method to contact area measurement. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Bacterial adhesion capacity on food service contact surfaces.

    Science.gov (United States)

    Fink, Rok; Okanovič, Denis; Dražič, Goran; Abram, Anže; Oder, Martina; Jevšnik, Mojca; Bohinc, Klemen

    2017-06-01

    The aim of this study was to analyse the adhesion of E. coli, P. aeruginosa and S. aureus on food contact materials, such as polyethylene terephthalate, silicone, aluminium, Teflon and glass. Surface roughness, streaming potential and contact angle were measured. Bacterial properties by contact angle and specific charge density were characterised. The bacterial adhesion analysis using staining method and scanning electron microscopy showed the lowest adhesion on smooth aluminium and hydrophobic Teflon for most of the bacteria. However, our study indicates that hydrophobic bacteria with high specific charge density attach to those surfaces more intensively. In food services, safety could be increased by selecting material with low adhesion to prevent cross contamination.

  2. Apparent Contact Angle and Contact Angle Hysteresis on Liquid Infused Surfaces

    OpenAIRE

    Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim

    2016-01-01

    We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a strong dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small b...

  3. Contact angle of unset elastomeric impression materials.

    Science.gov (United States)

    Menees, Timothy S; Radhakrishnan, Rashmi; Ramp, Lance C; Burgess, John O; Lawson, Nathaniel C

    2015-10-01

    Some elastomeric impression materials are hydrophobic, and it is often necessary to take definitive impressions of teeth coated with some saliva. New hydrophilic materials have been developed. The purpose of this in vitro study was to compare contact angles of water and saliva on 7 unset elastomeric impression materials at 5 time points from the start of mixing. Two traditional polyvinyl siloxane (PVS) (Aquasil, Take 1), 2 modified PVS (Imprint 4, Panasil), a polyether (Impregum), and 2 hybrid (Identium, EXA'lence) materials were compared. Each material was flattened to 2 mm and a 5 μL drop of distilled water or saliva was dropped on the surface at 25 seconds (t0) after the start of mix. Contact angle measurements were made with a digital microscope at initial contact (t0), t1=2 seconds, t2=5 seconds, t3=50% working time, and t4=95% working time. Data were analyzed with a generalized linear mixed model analysis, and individual 1-way ANOVA and Tukey HSD post hoc tests (α=.05). For water, materials grouped into 3 categories at all time-points: the modified PVS and one hybrid material (Identium) produced the lowest contact angles, the polyether material was intermediate, and the traditional PVS materials and the other hybrid (EXA'lence) produced the highest contact angles. For saliva, Identium, Impregum, and Imprint 4 were in the group with the lowest contact angle at most time points. Modified PVS materials and one of the hybrid materials are more hydrophilic than traditional PVS materials when measured with water. Saliva behaves differently than water in contact angle measurement on unset impression material and produces a lower contact angle on polyether based materials. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  4. Artificial neural network (ANN) approach for modeling of Pb(II) adsorption from aqueous solution by Antep pistachio (Pistacia Vera L.) shells.

    Science.gov (United States)

    Yetilmezsoy, Kaan; Demirel, Sevgi

    2008-05-30

    A three-layer artificial neural network (ANN) model was developed to predict the efficiency of Pb(II) ions removal from aqueous solution by Antep pistachio (Pistacia Vera L.) shells based on 66 experimental sets obtained in a laboratory batch study. The effect of operational parameters such as adsorbent dosage, initial concentration of Pb(II) ions, initial pH, operating temperature, and contact time were studied to optimise the conditions for maximum removal of Pb(II) ions. On the basis of batch test results, optimal operating conditions were determined to be an initial pH of 5.5, an adsorbent dosage of 1.0 g, an initial Pb(II) concentration of 30 ppm, and a temperature of 30 degrees C. Experimental results showed that a contact time of 45 min was generally sufficient to achieve equilibrium. After backpropagation (BP) training combined with principal component analysis (PCA), the ANN model was able to predict adsorption efficiency with a tangent sigmoid transfer function (tansig) at hidden layer with 11 neurons and a linear transfer function (purelin) at output layer. The Levenberg-Marquardt algorithm (LMA) was found as the best of 11 BP algorithms with a minimum mean squared error (MSE) of 0.000227875. The linear regression between the network outputs and the corresponding targets were proven to be satisfactory with a correlation coefficient of about 0.936 for five model variables used in this study.

  5. Removal of Ca(II) and Mg(II) from potassium chromate solution on Amberlite IRC 748 synthetic resin by ion exchange

    International Nuclear Information System (INIS)

    Yu Zhihui; Qi Tao; Qu Jingkui; Wang Lina; Chu Jinglong

    2009-01-01

    Experimental measurements have been made on the batch ion exchange of Ca(II) and Mg(II) from potassium chromate solution using cation exchanger of Amberlite IRC 748 as K + form. The ion exchange behavior of two alkaline-earth metals on the resin, depending on contact time, pH, temperature and resin dosage was studied. The adsorption isotherms were described by means of the Langmuir and Freundlich isotherms. For Ca(II) ion, the Langmuir model represented the adsorption process better than the Freundlich model. The maximum ion exchange capacity was found to be 47.21 mg g -1 for Ca(II) and 27.70 mg g -1 for Mg(II). The kinetic data were tested using Lagergren-first-order and pseudo-second-order kinetic models. Kinetic data correlated well with the pseudo-second-order kinetic model, indicating that the chemical adsorption was the rate-limiting step. Various thermodynamic parameters such as Gibbs free energy (ΔG o ), enthalpy (ΔH o ) and entropy (ΔS o ) were also calculated. These parameters showed that the ion exchange of Ca(II) and Mg(II) from potassium chromate solution was feasible, spontaneous and endothermic process in nature. The activation energy of ion-exchange (E a ) was determined as 12.34 kJ mol -1 for Ca(II) and 9.865 kJ mol -1 for Mg(II) according to the Arrhenius equation.

  6. Network analysis of pig movements: Loyalty patterns and contact chains of different holding types in Denmark.

    Science.gov (United States)

    Schulz, Jana; Boklund, Anette; Halasa, Tariq H B; Toft, Nils; Lentz, Hartmut H K

    2017-01-01

    Understanding animal movements is an important factor for the development of meaningful surveillance and control programs, but also for the development of disease spread models. We analysed the Danish pig movement network using static and temporal network analysis tools to provide deeper insight in the connection between holdings dealing with pigs, such as breeding and multiplier herds, production herds, slaughterhouses or traders. Pig movements, which occurred between 1st January 2006 and 31st December 2015 in Denmark, were summarized to investigate temporal trends such as the number of active holdings, the number of registered movements and the number of pigs moved. To identify holdings and holding types with potentially higher risk for introduction or spread of diseases via pig movements, we determined loyalty patterns, annual network components and contact chains for the 24 registered holding types. The total number of active holdings as well as the number of pig movements decreased during the study period while the holding sizes increased. Around 60-90% of connections between two pig holdings were present in two consecutive years and around one third of the connections persisted within the considered time period. Weaner herds showed the highest level of in-loyalty, whereas we observed an intermediate level of in-loyalty for all breeding sites and for production herds. Boar stations, production herds and trade herds showed a high level of out-loyalty. Production herds constituted the highest proportion of holdings in the largest strongly connected component. All production sites showed low levels of in-going contact chains and we observed a high level of out-going contact chain for breeding and multiplier herds. Except for livestock auctions, all transit sites also showed low levels of out-going contact chains. Our results reflect the pyramidal structure of the underlying network. Based on the considered disease, the time frame for the calculation of network

  7. Network analysis of pig movements: Loyalty patterns and contact chains of different holding types in Denmark.

    Directory of Open Access Journals (Sweden)

    Jana Schulz

    Full Text Available Understanding animal movements is an important factor for the development of meaningful surveillance and control programs, but also for the development of disease spread models. We analysed the Danish pig movement network using static and temporal network analysis tools to provide deeper insight in the connection between holdings dealing with pigs, such as breeding and multiplier herds, production herds, slaughterhouses or traders. Pig movements, which occurred between 1st January 2006 and 31st December 2015 in Denmark, were summarized to investigate temporal trends such as the number of active holdings, the number of registered movements and the number of pigs moved. To identify holdings and holding types with potentially higher risk for introduction or spread of diseases via pig movements, we determined loyalty patterns, annual network components and contact chains for the 24 registered holding types. The total number of active holdings as well as the number of pig movements decreased during the study period while the holding sizes increased. Around 60-90% of connections between two pig holdings were present in two consecutive years and around one third of the connections persisted within the considered time period. Weaner herds showed the highest level of in-loyalty, whereas we observed an intermediate level of in-loyalty for all breeding sites and for production herds. Boar stations, production herds and trade herds showed a high level of out-loyalty. Production herds constituted the highest proportion of holdings in the largest strongly connected component. All production sites showed low levels of in-going contact chains and we observed a high level of out-going contact chain for breeding and multiplier herds. Except for livestock auctions, all transit sites also showed low levels of out-going contact chains. Our results reflect the pyramidal structure of the underlying network. Based on the considered disease, the time frame for the

  8. Evaluation of CNTs/MnO{sub 2} composite for adsorption of {sup 60}Co(II), {sup 65}Zn(II) and Cd(II) ions from aqueous solutions

    Energy Technology Data Exchange (ETDEWEB)

    Sharaf El-Deen, Sahar E.A.; Moussa, Saber I.; Mekawy, Zakaria A.; Shehata, Mohamed K.K.; Someda, Hanan H. [Atomic Energy Authority, Inshas (Egypt). Dept. of Nuclear Chemistry; Sadeek, Sadeek A. [Zagazig Univ. (Egypt). Dept. of Chemistry

    2017-03-01

    CNTs/MnO{sub 2} composite was synthesized by a co-precipitation method after preparation of carbon nanotubes (CNTs) using a chemical oxidation method and was characterized using Fourier transformer infrared (FT-IR), X-ray diffraction (XRD) and scanning electron microscope (SEM). The synthesized CNTs/MnO{sub 2} composite was used as a sorbent for the removal of some radionuclides ({sup 60}Co and {sup 65}Zn-radioisotopes) and Cd (II) ions from aqueous solutions. Different parameters affecting the removal process including pH, contact time and metal ion concentration were investigated. Isotherm and kinetic models were studied. Adsorption data was interpreted in terms of both Freundlich and Langmuir isotherms and indicated that the CNTs/MnO{sub 2} composite complied well with both Langmuir and Freundlich models for {sup 60}Co and Cd(II) ions and with the Freundlich model only for the {sup 65}Zn radioisotope. A pseudo-second-order model was effectively employed to describe the adsorption behavior of {sup 60}Co, {sup 65}Zn and Cd(II) ions. Desorption of {sup 60}Co and {sup 65}Zn and Cd(II) ions from loaded samples was studied using different eluents.

  9. Coordination behavior of tetraaza [N4] ligand towards Co(II), Ni(II), Cu(II), Cu(I) and Pd(II) complexes: Synthesis, spectroscopic characterization and anticancer activity

    Science.gov (United States)

    El-Boraey, Hanaa A.

    2012-11-01

    Novel eight Co(II), Ni(II), Cu(II), Cu(I) and Pd(II) complexes with [N4] ligand (L) i.e. 2-amino-N-{2-[(2-aminobenzoyl)amino]ethyl}benzamide have been synthesized and structurally characterized by elemental analysis, spectral, thermal (TG/DTG), magnetic, and molar conductivity measurements. On the basis of IR, mass, electronic and EPR spectral studies an octahedral geometry has been proposed for Co(II), Ni(II) complexes and Cu(II) chloride complex, square-pyramidal for Cu(I) bromide complex. For Cu(II) nitrate complex (6), Pd(II) complex (8) square planar geometry was proposed. The EPR data of Cu(II) complexes in powdered form indicate dx2-y2 ground state of Cu(II) ion. The antitumor activity of the synthesized ligand and some selected metal complexes has been studied. The palladium(II) complex (8) was found to display cytotoxicity (IC50 = 25.6 and 41 μM) against human breast cancer cell line MCF-7 and human hepatocarcinoma HEPG2 cell line.

  10. Female-partnered and single women's contact motivations and experiences with donor-linked families.

    Science.gov (United States)

    Goldberg, A E; Scheib, J E

    2015-06-01

    What are female-partnered and single mothers' motivations and experiences at one donor insemination (DI) program with regard to contacting other families who share the same sperm donor? By and large, women reported seeking contact to obtain (i) support for their children and/or themselves, and (ii) information about shared traits and medical problems, ultimately describing a range of contact experiences, both positive (e.g. special bond created) and negative (e.g. uncomfortable encounters). There is a growing phenomenon of donor insemination families-parents and/or offspring-seeking others who share their donor (i.e. are 'donor-linked'). There is limited understanding about parental motivations and experiences-especially in the presence of a second parent-due to the methodological constraints of previous quantitative studies. Semi-structured telephone interviews were conducted with 50 donor insemination mothers (14 single, 36 female-partnered). Participants were recruited by email invitation to parent members of a family-matching service at one donor insemination program in the USA. The criterion for inclusion was having matched to at least one donor-linked family. Among the 50 mothers interviewed, all had at least one child conceived via donor insemination, who was between ages 0 and 15 years at first contact. Families matched with a median of three donor-linked families (range 1-10). Interview data were analyzed through qualitative (i.e. thematic) analysis. Overarching themes emerged of seeking contact to obtain (i) support and (ii) information about children's shared physical and psychological traits. Some wanted to increase their child's family network, through adding a sibling, but more often as extended family. Data, from partnered parents especially, revealed the challenges of balancing the boundaries of family formed without the genetic link with the perceived benefits of exploring the child's donor origins. Interviews focused on openness and information

  11. Effect of contact and no-contact small-sided games on elite handball players.

    Science.gov (United States)

    Dello Iacono, Antonio; Martone, Domenico; Zagatto, Alessandro Moura; Meckel, Yoav; Sindiani, Mahmood; Milic, Mirjana; Padulo, Johnny

    2018-01-01

    This study aimed to investigate the effect of contact (C-SSG) and no-contact (NC-SSG) handball small-sided games (SSGs) on motion patterns and physiological responses of elite handball players. Twelve male handball players performed 10 C-SSG and 10 NC-SSG while being monitored through the heart rate (HR) and rate of perceived exertion (RPE) as physiological responses and time-motion activities profile using video-match analysis. Both game conditions resulted in similar HR responses (P > 0.05), but the NC-SSG led to a higher RPE scores. The time-motion activity analysis featured NC-SSG with a greater amount of walking (855.6 ± 25.1 vs. 690.6 ± 35.2 m) and backward movements (187.5 ± 12.3 vs. 142.5 ± 8.7 m) combined with fast running (232.3 ± 8.5 vs. 159.7 ± 5.7 m) and sprinting (79.5 ± 4.7 vs. 39.7 ± 3.7 m) activities (P handball can effectively represent specifically oriented exercises, according to the sport-task and the performance demands.

  12. Development of Wood Apple Shell (Feronia acidissima Powder Biosorbent and Its Application for the Removal of Cd(II from Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Ch. Suresh

    2014-01-01

    Full Text Available A biosorbent was prepared by using wood apple shell (WAS powder and studied its application for the removal of Cd(II from aqueous solution by a batch method. The biosorbent was characterized by infrared spectroscopy, X-ray diffraction, scanning electron microscopy, and elemental analysis. WAS is principally made up of lignin and cellulose, containing functional groups such as alcoholic, ketonic, and carboxylic groups which can be involved in complexation reactions with Cd(II. The effect of experimental parameters like initial pH, contact time, metal ion concentration, and sorbent dose on adsorption was investigated. The optimum pH for biosorption of Cd(II onto WAS was found to be pH 5.0 and the quantitative removal of Cd(II ions was achieved in 30 min. The kinetic study showed that the biosorption process followed the pseudo-second-order rate. Experimental data were analyzed by Langmuir, Freundlich, and Dubinin-Radushkevich isotherm models. Desorption studies were carried out using HCl solution.

  13. Contact Stress Generation on the UHMWPE Tibial Insert

    Directory of Open Access Journals (Sweden)

    S. Petrović Savić

    2014-12-01

    Full Text Available Total knee replacement (TKR is considered, during last years, as a very successful surgical technique for removing knee joint deformities and eliminating pain caused by cartilage damage. In literature, as primary causes for knee joint endoprothesis damage are cited complex movements which cause occurrences of complex stress conditions, sagital radius conformity, sliding, types of materials etc. Aim of this study is analysis of contact stresses that occur on tibial implant for 15°, 45° and 60° knee flexion and 50 kg, 75 kg, 100 kg and 125 kg weight. Knee joint prosthesis model and finite elements method (FEM analysis are done in software Catia V5. For this analysis we used ultra-high molecular weight polyethylene (UHMWPE for tibial implant material and AISI 316, AISI 317, AISI 321, 17-4PH, CoCrMo, Ti6Al4V and SAE A-286 for femoral component materials. Results show that area of maximal contact stress is identified in medial and lateral part of tibial implant. Von Mises stress values vary regarding of flexion degree and weight, but values are approximate for types of chosen materials. Contact stress location corresponds to damage that occur on tibial implant during exploitation.

  14. Real-time simulation of contact and cutting of heterogeneous soft-tissues.

    Science.gov (United States)

    Courtecuisse, Hadrien; Allard, Jérémie; Kerfriden, Pierre; Bordas, Stéphane P A; Cotin, Stéphane; Duriez, Christian

    2014-02-01

    This paper presents a numerical method for interactive (real-time) simulations, which considerably improves the accuracy of the response of heterogeneous soft-tissue models undergoing contact, cutting and other topological changes. We provide an integrated methodology able to deal both with the ill-conditioning issues associated with material heterogeneities, contact boundary conditions which are one of the main sources of inaccuracies, and cutting which is one of the most challenging issues in interactive simulations. Our approach is based on an implicit time integration of a non-linear finite element model. To enable real-time computations, we propose a new preconditioning technique, based on an asynchronous update at low frequency. The preconditioner is not only used to improve the computation of the deformation of the tissues, but also to simulate the contact response of homogeneous and heterogeneous bodies with the same accuracy. We also address the problem of cutting the heterogeneous structures and propose a method to update the preconditioner according to the topological modifications. Finally, we apply our approach to three challenging demonstrators: (i) a simulation of cataract surgery (ii) a simulation of laparoscopic hepatectomy (iii) a brain tumor surgery. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Type-II Weyl semimetals.

    Science.gov (United States)

    Soluyanov, Alexey A; Gresch, Dominik; Wang, Zhijun; Wu, QuanSheng; Troyer, Matthias; Dai, Xi; Bernevig, B Andrei

    2015-11-26

    Fermions--elementary particles such as electrons--are classified as Dirac, Majorana or Weyl. Majorana and Weyl fermions had not been observed experimentally until the recent discovery of condensed matter systems such as topological superconductors and semimetals, in which they arise as low-energy excitations. Here we propose the existence of a previously overlooked type of Weyl fermion that emerges at the boundary between electron and hole pockets in a new phase of matter. This particle was missed by Weyl because it breaks the stringent Lorentz symmetry in high-energy physics. Lorentz invariance, however, is not present in condensed matter physics, and by generalizing the Dirac equation, we find the new type of Weyl fermion. In particular, whereas Weyl semimetals--materials hosting Weyl fermions--were previously thought to have standard Weyl points with a point-like Fermi surface (which we refer to as type-I), we discover a type-II Weyl point, which is still a protected crossing, but appears at the contact of electron and hole pockets in type-II Weyl semimetals. We predict that WTe2 is an example of a topological semimetal hosting the new particle as a low-energy excitation around such a type-II Weyl point. The existence of type-II Weyl points in WTe2 means that many of its physical properties are very different to those of standard Weyl semimetals with point-like Fermi surfaces.

  16. Contact with turf algae alters the coral microbiome: contact versus systemic impacts

    Science.gov (United States)

    Pratte, Zoe A.; Longo, Guilherme O.; Burns, Andrew S.; Hay, Mark E.; Stewart, Frank J.

    2018-03-01

    Coral reefs are degrading to algae-dominated reefs worldwide, with alterations of coral microbiomes commonly co-occurring with reef demise. The severe thermal anomaly during the 2016 El Niño event in the South Pacific killed many corals and stressed others. We examined the microbiome of turf algae and of the coral Porites sp. in contact with turf during this thermal event to investigate algal turf effects on the coral microbiome during a period of environmental stress. The microbial composition of turf did not differ between coral-contacted and non-contacted turfs. However, microbiomes of corals in direct contact with turf were similar to those of the turf microbiome, but differed significantly from coral portions 5 cm from the point of turf/coral contact and from portions of the coral that looked most healthy, regardless of location. Although the majority of significant differences occurred in coral samples at the point of contact, a small subset of microbial taxa was enriched in coral tissues taken 5 cm from turf contact compared to all other sample types, including samples from areas of the coral that appeared most healthy. These results suggest that the coral microbiome is susceptible to colonization by microbes from turf, but not vice versa. Results also suggest that algal contact elicits a subtle shift in the coral microbiome just beyond the contact site. The combination of turf microbiome stability and coral microbiome vulnerability at areas of contact may contribute to the continued decline in coral cover and increase in algal cover associated with coral-algae phase shifts.

  17. Synthesis, characterization and thermal studies of nickel (II), copper (II), zinc (II) and cadmium (II) complexes with some mixed ligands

    International Nuclear Information System (INIS)

    Mitra, Samiran; Kundu, Parimal; Singh, Rajkumar Bhubon

    1998-01-01

    Dichloro-(DCA) and trichloroacetate(TCA) -cyclic ligand morpholine (Morph)/thiomorpholine (Tmorph)/methylmorpholine (Mmorph)/dimethyl-piperazine (DMP) complexes of nickel (II), copper (II), zinc (II) and cadmium (II) with the compositions [Ni(tmorph) 2 (DCA) 2 ], [Ni(tmorph) 2 (TCA) 2 ].2H 2 O, [Cu(DMP) 2 (TCA) 2 ],[ML 2 X 2 ].nH 2 O where M=Zn II or Cd II , L=Morph, DMP or tmorph and X=DCA or TCA and n=O except in case of [Cd (Morph) 2 (TCA) 2 ] where n=1 have been synthesised. Some intermediate complexes have been isolated by temperature arrest technique (pyrolysis) and characterised. Configurational and conformational changes have been studied by elemental analyses, IR and electronic spectra, magnetic moment data (in the case of Ni(II) and Cu(II) complexes) and thermal analysis. E a * , ΔH, and ΔS for the decomposition reaction of these complexes are evaluated and the stability of the complexes with respect to activation energy has also been compared. The linear correlation has been found between E a * and ΔS for the decomposition of the complexes. (author)

  18. Patients with multiple contact allergies

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Andersen, Klaus Ejner; Menné, Torkil

    2008-01-01

    Patients with multiple contact allergies, also referred to as polysensitized, are more frequent than predicted from prevalence of single sensitivities. The understanding of why some people develop multiple contact allergies, and characterization of patients with multiple contact allergies...... of developing multiple contact allergies. Evidence of allergen clusters among polysensitized individuals is also reviewed. The literature supports the idea that patients with multiple contact allergies constitute a special entity within the field of contact allergy. There is no generally accepted definition...... of patients with multiple contact allergies. We suggest that contact allergy to 3 or more allergens are defined as multiple contact allergies....

  19. Evaluation of residue-residue contact prediction in CASP10

    KAUST Repository

    Monastyrskyy, Bohdan

    2013-08-31

    We present the results of the assessment of the intramolecular residue-residue contact predictions from 26 prediction groups participating in the 10th round of the CASP experiment. The most recently developed direct coupling analysis methods did not take part in the experiment likely because they require a very deep sequence alignment not available for any of the 114 CASP10 targets. The performance of contact prediction methods was evaluated with the measures used in previous CASPs (i.e., prediction accuracy and the difference between the distribution of the predicted contacts and that of all pairs of residues in the target protein), as well as new measures, such as the Matthews correlation coefficient, the area under the precision-recall curve and the ranks of the first correctly and incorrectly predicted contact. We also evaluated the ability to detect interdomain contacts and tested whether the difficulty of predicting contacts depends upon the protein length and the depth of the family sequence alignment. The analyses were carried out on the target domains for which structural homologs did not exist or were difficult to identify. The evaluation was performed for all types of contacts (short, medium, and long-range), with emphasis placed on long-range contacts, i.e. those involving residues separated by at least 24 residues along the sequence. The assessment suggests that the best CASP10 contact prediction methods perform at approximately the same level, and comparably to those participating in CASP9.

  20. Estimating the role of casual contact from the community in transmission of Bordetella pertussis to young infants

    Directory of Open Access Journals (Sweden)

    Poole Charles

    2007-10-01

    Full Text Available Abstract The proportion of infant pertussis cases due to transmission from casual contact in the community has not been estimated since before the introduction of pertussis vaccines in the 1950s. This study aimed to estimate the proportion of pertussis transmission due to casual contact using demographic and clinical data from a study of 95 infant pertussis cases and their close contacts enrolled at 14 hospitals in France, Germany, Canada, and the U.S. between February 2003 and September 2004. A complete case analysis was conducted as well as multiple imputation (MI to account for missing data for participants and close contacts who did not participate. By considering all possible close contacts, the MI analysis estimated 66% of source cases were close contacts, implying the minimum attributable proportion of infant cases due to transmission from casual contact with community members was 34% (95% CI = 24%, 44%. Estimates from the complete case analysis were comparable but less precise. Results were sensitive to changes in the operational definition of a source case, which broadened the range of MI point estimates of transmission from casual community contact to 20%–47%. We conclude that casual contact appears to be responsible for a substantial proportion of pertussis transmission to young infants. Medical subject headings (MeSH: multiple imputation, pertussis, transmission, casual contact, sensitivity analysis, missing data, community.

  1. Modelling tyre-road contact stresses in pavement design and analysis

    CSIR Research Space (South Africa)

    Maina, JW

    2013-07-01

    Full Text Available between rolling tyres and the road structure it needs to be durable so as to withstand current traffic loading and hence contact stresses, given the environmental forces also acting on it. For road infrastructure to perform as expected, it is important...

  2. An empirical analysis of the multimarket contact theory in pharmaceutical markets.

    Science.gov (United States)

    Coronado, Javier; Jiménez-Martín, Sergi; Marín, Pedro L

    2014-07-01

    Multimarket contact theory predicts that firms will optimally reduce prices in markets where collusive prices are sustainable and allocate the slack of the corresponding incentive compatibility to increase prices in markets where collusion is not sustainable. Binding price caps in collusive markets will have different effects over the multimarket contact mechanism depending on the severity of the cap. Setting a price cap close to the unregulated case will increase the size of the redistribution of market power whereas stronger regulation will even reduce prices in unregulated markets. Therefore, price regulations aiming at capping prices in a specific market will also affect markets that are not subject to specific mandatory price regulations. We find evidence of the theory predictions using information for nine OECD countries for pharmaceutical markets. Unregulated US markets are shown to respond to the redistribution effect; Canadian markets, known to be subject to soft price regulations, with respect to the former, are shown to be consistent with a stronger redistribution effect. EU markets and Japan are either consistent with the effect of a medium regulation or strong regulation. In this last case multimarket contact cannot explain prices, and these are expected to be lower compared to the unregulated benchmark.

  3. Drop shape visualization and contact angle measurement on curved surfaces.

    Science.gov (United States)

    Guilizzoni, Manfredo

    2011-12-01

    The shape and contact angles of drops on curved surfaces is experimentally investigated. Image processing, spline fitting and numerical integration are used to extract the drop contour in a number of cross-sections. The three-dimensional surfaces which describe the surface-air and drop-air interfaces can be visualized and a simple procedure to determine the equilibrium contact angle starting from measurements on curved surfaces is proposed. Contact angles on flat surfaces serve as a reference term and a procedure to measure them is proposed. Such procedure is not as accurate as the axisymmetric drop shape analysis algorithms, but it has the advantage of requiring only a side view of the drop-surface couple and no further information. It can therefore be used also for fluids with unknown surface tension and there is no need to measure the drop volume. Examples of application of the proposed techniques for distilled water drops on gemstones confirm that they can be useful for drop shape analysis and contact angle measurement on three-dimensional sculptured surfaces. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Equilibrium modeling of mono and binary sorption of Cu(II and Zn(II onto chitosan gel beads

    Directory of Open Access Journals (Sweden)

    Nastaj Józef

    2016-12-01

    Full Text Available The objective of the work are in-depth experimental studies of Cu(II and Zn(II ion removal on chitosan gel beads from both one- and two-component water solutions at the temperature of 303 K. The optimal process conditions such as: pH value, dose of sorbent and contact time were determined. Based on the optimal process conditions, equilibrium and kinetic studies were carried out. The maximum sorption capacities equaled: 191.25 mg/g and 142.88 mg/g for Cu(II and Zn(II ions respectively, when the sorbent dose was 10 g/L and the pH of a solution was 5.0 for both heavy metal ions. One-component sorption equilibrium data were successfully presented for six of the most useful three-parameter equilibrium models: Langmuir-Freundlich, Redlich-Peterson, Sips, Koble-Corrigan, Hill and Toth. Extended forms of Langmuir-Freundlich, Koble-Corrigan and Sips models were also well fitted to the two-component equilibrium data obtained for different ratios of concentrations of Cu(II and Zn(II ions (1:1, 1:2, 2:1. Experimental sorption data were described by two kinetic models of the pseudo-first and pseudo-second order. Furthermore, an attempt to explain the mechanisms of the divalent metal ion sorption process on chitosan gel beads was undertaken.

  5. Adsorption of Cd(II) and Cu(II) from aqueous solution by carbonate hydroxylapatite derived from eggshell waste

    International Nuclear Information System (INIS)

    Zheng Wei; Li Xiaoming; Yang Qi; Zeng Guangming; Shen Xiangxin; Zhang Ying; Liu Jingjin

    2007-01-01

    Carbonate hydroxylapatite (CHAP) synthesized by using eggshell waste as raw material has been investigated as metal adsorption for Cd(II) and Cu(II) from aqueous solutions. The effect of various parameters on adsorption process such as contact time, solution pH, amount of CHAP and initial concentration of metal ions was studied at room temperature to optimize the conditions for maximum adsorption. The results showed that the removal efficiency of Cd(II) and Cu(II) by CHAP could reach 94 and 93.17%, respectively, when the initial Cd(II) concentration 80 mg/L and Cu(II) 60 mg/L and the liquid/solid ratio was 2.5 g/L. The equilibrium sorption data for single metal systems at room temperature could be described by the Langmuir and Freundlich isotherm models. The highest value of Langmuir maximum uptake, (b), was found for cadmium (111.1 mg/g) and copper (142.86 mg/g). Similar Freundlich empirical constants, K, were obtained for cadmium (2.224) and copper (7.925). Ion exchange and surface adsorption might be involved in the adsorption process of cadmium and copper. Desorption experiments showed that CaCl 2 , NaCl, acetic acid and ultrasonic were not efficient enough to desorb substantial amount of metal ions from the CHAP. The results obtained show that CHAP has a high affinity to cadmium and copper

  6. Time series analysis of nuclear instrumentation in EBR-II

    International Nuclear Information System (INIS)

    Imel, G.R.

    1996-01-01

    Results of a time series analysis of the scaler count data from the 3 wide range nuclear detectors in the Experimental Breeder Reactor-II are presented. One of the channels was replaced, and it was desired to determine if there was any statistically significant change (ie, improvement) in the channel's response after the replacement. Data were collected from all 3 channels for 16-day periods before and after detector replacement. Time series analysis and statistical tests showed that there was no significant change after the detector replacement. Also, there were no statistically significant differences among the 3 channels, either before or after the replacement. Finally, it was determined that errors in the reactivity change inferred from subcritical count monitoring during fuel handling would be on the other of 20-30 cents for single count intervals

  7. Role of Firing Temperature, Sheet Resistance, and Contact Area in Contact Formation on Screen-Printed Metal Contact of Silicon Solar Cell

    Science.gov (United States)

    Ahmad, Samir Mahmmod; Leong, Cheow Siu; Sopian, K.; Zaidi, Saleem H.

    2018-03-01

    Formation of an Ohmic contact requires a suitable firing temperature, appropriate doping profile, and contact dimensions within resolution limits of the screen-printing process. In this study, the role of the peak firing temperature in standard rapid thermal annealing (RTA) six-zone conveyor belt furnace (CBF) and two inexpensive alternate RTA systems [a custom-designed, three-zone, 5″-diameter quartz tube furnace (QTF) and a tabletop, 3″-diameter rapid thermal processing (RTP)] has been investigated. In addition, the role of sheet resistance and contact area in achieving low-resistance ohmic contacts has been examined. Electrical measurements of ohmic contacts between silver paste/ n +-emitter layer with varying sheet resistances and aluminum paste/ p-doped wafer were carried out in transmission line method configuration. Experimental measurements of the contact resistivity ( ρ c) exhibited the lowest values for CBF at 0.14 mΩ cm2 for Ag and 100 mΩ cm2 for Al at a peak firing temperature of 870°C. For the QTF configuration, lowest measured contact resistivities were 3.1 mΩ cm2 for Ag and 74.1 mΩ cm2 for Al at a peak firing temperature of 925°C. Finally, for the RTP configuration, lowest measured contact resistivities were 1.2 mΩ cm2 for Ag and 68.5 mΩ cm2 for Al at a peak firing temperature of 780°C. The measured contact resistivity exhibits strong linear dependence on sheet resistance. The contact resistivity for Ag decreases with contact area, while for Al the opposite behavior is observed.

  8. Complexes cobalt(II, zinc(II and copper(II with some newly synthesized benzimidazole derivatives and their antibacterial activity

    Directory of Open Access Journals (Sweden)

    S. O. PODUNAVAC-KUZMANOVIC

    1999-05-01

    Full Text Available The preparation and properties of some complexes of cobalt(II, zinc(II and copper(II with several newly synthesized benzimidazole derivatives (L are reported. The complexes, of the general formula [MCl2L2] (M=Co(II, Zn(II and [CuCl2L(H2O], have a tetrahedral structure. The complexes were characterized by elemental analysis, molar conductivity, magnetic susceptibility measurements, IR and absorption electronic spectra. The antibacterial activitiy of the benzimidazoles and their complexes was evaluated against Erwinia carotovora subsp. carotovora and Erwinia amylovora. The complexes were found to be more toxic than the ligands.

  9. An approximate JKR solution for a general contact, including rough contacts

    Science.gov (United States)

    Ciavarella, M.

    2018-05-01

    In the present note, we suggest a simple closed form approximate solution to the adhesive contact problem under the so-called JKR regime. The derivation is based on generalizing the original JKR energetic derivation assuming calculation of the strain energy in adhesiveless contact, and unloading at constant contact area. The underlying assumption is that the contact area distributions are the same as under adhesiveless conditions (for an appropriately increased normal load), so that in general the stress intensity factors will not be exactly equal at all contact edges. The solution is simply that the indentation is δ =δ1 -√{ 2 wA‧ /P″ } where w is surface energy, δ1 is the adhesiveless indentation, A‧ is the first derivative of contact area and P‧‧ the second derivative of the load with respect to δ1. The solution only requires macroscopic quantities, and not very elaborate local distributions, and is exact in many configurations like axisymmetric contacts, but also sinusoidal waves contact and correctly predicts some features of an ideal asperity model used as a test case and not as a real description of a rough contact problem. The solution permits therefore an estimate of the full solution for elastic rough solids with Gaussian multiple scales of roughness, which so far was lacking, using known adhesiveless simple results. The result turns out to depend only on rms amplitude and slopes of the surface, and as in the fractal limit, slopes would grow without limit, tends to the adhesiveless result - although in this limit the JKR model is inappropriate. The solution would also go to adhesiveless result for large rms amplitude of roughness hrms, irrespective of the small scale details, and in agreement with common sense, well known experiments and previous models by the author.

  10. Comparison of analysis and experiment for dynamics of low-contact-ratio spur gears

    Science.gov (United States)

    Oswald, Fred B.; Rebbechi, Brian; Zakrajsek, James J.; Townsend, Dennis P.; Lin, Hsiang Hsi

    1991-01-01

    Low-contact-ratio spur gears were tested in NASA gear-noise-rig to study gear dynamics including dynamic load, tooth bending stress, vibration, and noise. The experimental results were compared with a NASA gear dynamics code to validate the code as a design tool for predicting transmission vibration and noise. Analytical predictions and experimental data for gear-tooth dynamic loads and tooth-root bending stress were compared at 28 operating conditions. Strain gage data were used to compute the normal load between meshing teeth and the bending stress at the tooth root for direct comparison with the analysis. The computed and measured waveforms for dynamic load and stress were compared for several test conditions. These are very similar in shape, which means the analysis successfully simulates the physical behavior of the test gears. The predicted peak value of the dynamic load agrees with the measurement results within an average error of 4.9 percent except at low-torque, high-speed conditions. Predictions of peak dynamic root stress are generally within 10 to 15 percent of the measured values.

  11. Synthetic hydroxyapatites doped with Zn(II) studied by X-ray diffraction, infrared, Raman and thermal analysis

    Science.gov (United States)

    Guerra-López, José R.; Echeverría, Gustavo A.; Güida, Jorge A.; Viña, Raúl; Punte, Graciela

    2015-06-01

    Calcium hydroxyapatite (CaHap) formation when different amounts of Zn(II) are present in the mother solution has been investigated by atomic absorption, infrared and Raman spectroscopies, X-ray diffraction and thermal analysis (DTA and TG). The studied samples have been synthesized at T=95 °C and pH 9 in air. The analysis of the results have shown that the pure CaHap sample crystallizes in the monoclinic form P21/b. Concentrations up to 20% of Zn(II) in the mother solution, equivalent to smaller concentrations in solid (up to 9.1% in wt), favor the formation of the hexagonal apatite, P63/m, while Zn(II) concentrations higher than 20% in solution help an amorphous phase development where vibrational spectra indicated coexistence of two phases: an apatite and ZnNH4PO4·H2O. Infrared data of thermal treated samples endorse that HPO42- ion had not been incorporated in Zn(II) doped samples during the synthesis process. Present results also allow to conclude that Zn(II) cation exhibits a preference to occupy the Ca2 site of the apatite structure and induces water adsorption and a small quantity of CO32- cation incorporation, leading to formation of a less crystalline Ca deficient apatite.

  12. HTSC-Josephson step contacts

    International Nuclear Information System (INIS)

    Herrmann, K.

    1994-03-01

    In this work the properties of josephson step contacts are investigated. After a short introduction into Josephson step contacts the structure, properties and the Josphson contacts of YBa 2 Cu 3 O 7-x high-T c superconductors is presented. The fabrication of HTSC step contacts and the microstructure is discussed. The electric properties of these contacts are measured together with the Josephson emission and the magnetic field dependence. The temperature dependence of the stationary transport properties is given. (WL)

  13. [Children from the GAZEL cohort: II--motive for contact with the medical-educational system by age and sex].

    Science.gov (United States)

    Fombonne, E; Vermeersch, S

    1997-04-01

    An epidemiological survey of 2582 French children aged 4 to 16 has been conducted to assess patterns of service use in relation to psychological disturbances. Details on the design, sample, survey instruments, response rate, and 12-months prevalence rates of contacts with a range of different professionals were presented in a previous article. In this second article, the psychological motives leading to contact with family doctors, school-based professionals, speech and language therapists, and mental health specialists are analyzed. The age and gender effects are assessed for each motives. On the whole, consistent sex differences were found for the types of complaints presented by service users, with emotional symptoms being more frequent amongst girls, and behavioural, developmental and learning difficulties being more frequent amongst boys. Mental health specialists were attended for a variety of reasons. Family doctors were contacted for minor emotional difficulties. Because family doctors were consulted by a high proportion of children and adolescents of our sample, the role of this professionals in the detection and management of minor psychological morbidity is emphasized.

  14. Contact enhancement of locomotion in spreading cell colonies

    Science.gov (United States)

    D'Alessandro, Joseph; Solon, Alexandre P.; Hayakawa, Yoshinori; Anjard, Christophe; Detcheverry, François; Rieu, Jean-Paul; Rivière, Charlotte

    2017-10-01

    The dispersal of cells from an initially constrained location is a crucial aspect of many physiological phenomena, ranging from morphogenesis to tumour spreading. In such processes, cell-cell interactions may deeply alter the motion of single cells, and in turn the collective dynamics. While contact phenomena like contact inhibition of locomotion are known to come into play at high densities, here we focus on the little explored case of non-cohesive cells at moderate densities. We fully characterize the spreading of micropatterned colonies of Dictyostelium discoideum cells from the complete set of individual trajectories. From data analysis and simulation of an elementary model, we demonstrate that contact interactions act to speed up the early population spreading by promoting individual cells to a state of higher persistence, which constitutes an as-yet unreported contact enhancement of locomotion. Our findings also suggest that the current modelling paradigm of memoryless active particles may need to be extended to account for the history-dependent internal state of motile cells.

  15. The effect of compliance on contact lens case contamination.

    Science.gov (United States)

    Tilia, Daniel; Lazon de la Jara, Percy; Zhu, Hua; Naduvilath, Thomas J; Holden, Brien A

    2014-03-01

    To determine the efficacy of written instructions on contact lens case hygiene and to quantify the effect of noncompliance on contact lens case contamination. Data were retrospectively analyzed from 16 prospective, 3-month daily-wear studies during which six commercially available silicone hydrogel contact lenses and seven lens care solutions (LCS) were tested following a similar protocol. Verbal instructions regarding case hygiene (rinse case with LCS, not tap water) were given in nine studies, while the same instructions were given verbally and in written format in seven studies. A survey on contact lens, LCS, and lens case hygiene was completed at 1- and 3-month visits and compliance with case hygiene instructions was determined. Regular contact lens cases were used for 1 month and collected for microbial analysis at the 1- and 3-month visits. The rate of case contamination and the types of microbes contaminating cases were evaluated. Participants given verbal and written instructions were more likely to be compliant with case hygiene instructions than those just given verbal instructions (odds ratio [OR]: 2.19, p hygiene can be improved by effective communication of instructions. Contact lens wearers should be actively discouraged from rinsing contact lens cases with tap water because of the increased risk of GNB contamination.

  16. Effects of pressure and temperature on thermal contact resistance between different materials

    Directory of Open Access Journals (Sweden)

    Zhao Zhe

    2015-01-01

    Full Text Available To explore whether pressure and temperature can affect thermal contact resistance, we have proposed a new experimental approach for measurement of the thermal contact resistance. Taking the thermal contact resistance between phenolic resin and carbon-carbon composites, cuprum, and aluminum as the examples, the influence of the thermal contact resistance between specimens under pressure is tested by experiment. Two groups of experiments are performed and then an analysis on influencing factors of the thermal contact resistance is presented in this paper. The experimental results reveal that the thermal contact resistance depends not only on the thermal conductivity coefficient of materials, but on the interfacial temperature and pressure. Furthermore, the thermal contact resistance between cuprum and aluminum is more sensitive to pressure and temperature than that between phenolic resin and carbon-carbon composites.

  17. Level II scour analysis for Bridge 16 (GROTTH00170016) on Town Highway 17, crossing the Wells River, Groton, Vermont

    Science.gov (United States)

    Striker, L.K.; Ivanoff, M.A.

    1997-01-01

    This report provides the results of a detailed Level II analysis of scour potential at structure GROTTH00170016 on Town Highway 17 crossing the Wells River, Groton, Vermont (figures 1–8). A Level II study is a basic engineering analysis of the site, including a quantitative analysis of stream stability and scour (U.S. Department of Transportation, 1993). Results of a Level I scour investigation also are included in Appendix E of this report. A Level I investigation provides a qualitative geomorphic characterization of the study site. Information on the bridge, gleaned from Vermont Agency of Transportation (VTAOT) files, was compiled prior to conducting Level I and Level II analyses and is found in Appendix D.

  18. Level II scour analysis for Bridge 37, (BRNETH00740037) on Town Highway 74, crossing South Peacham Brook, Barnet, Vermont

    Science.gov (United States)

    Burns, Ronda L.; Severance, Timothy

    1997-01-01

    This report provides the results of a detailed Level II analysis of scour potential at structure BRNETH00740037 on Town Highway 74 crossing South Peacham Brook, Barnet, Vermont (figures 1–8). A Level II study is a basic engineering analysis of the site, including a quantitative analysis of stream stability and scour (U.S. Department of Transportation, 1993). Results of a Level I scour investigation also are included in Appendix E of this report. A Level I investigation provides a qualitative geomorphic characterization of the study site. Information on the bridge, gleaned from Vermont Agency of Transportation (VTAOT) files, was compiled prior to conducting Level I and Level II analyses and is found in Appendix D.

  19. Level II scour analysis for Bridge 37 (BARTTH00080037) on Town Highway 8, crossing Willoughby River, Barton, Vermont

    Science.gov (United States)

    Ayotte, Joseph D.; Boehmler, Erick M.

    1996-01-01

    This report provides the results of a detailed Level II analysis of scour potential at structure BARTTH00080037 on town highway 8 crossing the Willoughby River, Barton, Vermont (figures 1–8). A Level II study is a basic engineering analysis of the site, including a quantitative analysis of stream stability and scour (U.S. Department of Transportation, 1993). Results of a Level I scour investigation also are included in Appendix E of this report. A Level I investigation provides a qualitative geomorphic characterization of the study site. Information on the bridge, gleaned from Vermont Agency of Transportation (VTAOT) files, was compiled prior to conducting Level I and Level II analyses and is found in Appendix D. The site is in the New England Upland section of the New England physiographic province

  20. A noise-resistant ADSA-PH algorithm for superhydrophobic surface’s static contact angle evaluation

    OpenAIRE

    Z. N. Xu

    2017-01-01

    The blur around the contact points significantly decreases the evaluated static contact angle for superhydrophobic surface which is clearly presented in the paper. To improve the accuracy in the evaluated static contact angle for superhydrophobic surface, an accurate static contact angle algorithm, namely ADSA-PH (axisymmetric drop shape analysis-profile and height), is proposed. It discards the extracted drop edge points close to the contact points and makes use of the residual points and th...