WorldWideScience

Sample records for contact time direct

  1. Participant observation of time allocation, direct patient contact and simultaneous activities in hospital physicians

    Directory of Open Access Journals (Sweden)

    Zupanc Andrea

    2009-06-01

    Full Text Available Abstract Background Hospital physicians' time is a critical resource in medical care. Two aspects are of interest. First, the time spent in direct patient contact – a key principle of effective medical care. Second, simultaneous task performance ('multitasking' which may contribute to medical error, impaired safety behaviour, and stress. There is a call for instruments to assess these aspects. A preliminary study to gain insight into activity patterns, time allocation and simultaneous activities of hospital physicians was carried out. Therefore an observation instrument for time-motion-studies in hospital settings was developed and tested. Methods 35 participant observations of internists and surgeons of a German municipal 300-bed hospital were conducted. Complete day shifts of hospital physicians on wards, emergency ward, intensive care unit, and operating room were continuously observed. Assessed variables of interest were time allocation, share of direct patient contact, and simultaneous activities. Inter-rater agreement of Kappa = .71 points to good reliability of the instrument. Results Hospital physicians spent 25.5% of their time at work in direct contact with patients. Most time was allocated to documentation and conversation with colleagues and nursing staff. Physicians performed parallel simultaneous activities for 17–20% of their work time. Communication with patients, documentation, and conversation with colleagues and nursing staff were the most frequently observed simultaneous activities. Applying logit-linear analyses, specific primary activities increase the probability of particular simultaneous activities. Conclusion Patient-related working time in hospitals is limited. The potential detrimental effects of frequently observed simultaneous activities on performance outcomes need further consideration.

  2. Visualization of direct contact heat transfer between water and molten alloy

    International Nuclear Information System (INIS)

    Nishi, Yoshihisa; Furuya, Masahiro; Kinoshita, Izumi; Takenaka, Nobuyuki; Matsubayashi, Masahito.

    1996-01-01

    We have been developing an innovative Steam Generator concept of Fast Breeder Reactors by using liquid-liquid direct contact heat transfer. In this concept, the SG shell is filled with a molten alloys, which is heated by primary sodium. Water is fed into the high temperature molten alloy, and evaporates by direct contact heating. In order to obtain the fundamental information to discuss the heat transfer mechanisms of the direct contact between the water and the alloy, this phenomenon was visualized by real-time neutron radiography. JRR-3M real-time thermal neutron radiography in Japan Atomic Energy Research Institute was used. Followings are main results. (1) The vigorous evaporation occurs in the molten alloy. This phenomena is different from the known phenomenon such as the evaporation of refrigerant R-113 in the water. (2) The evaporation in the bubble has finished in a moment due to high heat transfer performance between the liquid and molten alloy. (3) It is confirmed that the velocity of bubble with the rapid evaporation and growth is about 50 cm/s. (author)

  3. Liquid-Metal/Water Direct Contact Heat Exchange: Flow Visualization, Flow Stability, and Heat Transfer Using Real-Time X-Ray Imaging

    International Nuclear Information System (INIS)

    Abdulla, Sherif H.; Liu Xin; Anderson, Mark H.; Bonazza, Riccardo; Corradini, Michael L.; Cho, Dae; Page, Richard

    2005-01-01

    Advanced reactor system designs are being considered with liquid-metal cooling connected to a steam power cycle. In addition, current reactor safety systems are considering auxiliary cooling schemes that assure ex-vessel debris coolability utilizing direct water injection into molten material pools to achieve core quenching and eventual coolability. The phenomenon common in both applications is direct contact heat exchange. The current study focuses on detailed measurements of liquid-metal/water direct contact heat exchange that is directly applicable to improvements in effective heat transfer in devices that are being considered for both of these purposes.In this study, a test facility was designed at the University of Wisconsin-Madison to map the operating range of liquid-metal/water direct contact heat exchange. The test section (184-cm height, 45.75-cm width, and 10-cm depth) is a rectangular slice of a larger heat exchange device. This apparatus was used not only to provide measurements of integral thermal performance (i.e., volumetric heat transfer coefficient), but also local heat transfer coefficients in a bubbly flow regime with X-ray imaging based on measured parameters such as bubble formation time, bubble rise velocity, and bubble diameters.To determine these local heat transfer coefficients, a complete methodology of the X-ray radiography for two-phase flow measurement has been developed. With this methodology, a high-energy X-ray imaging system is optimized for our heat exchange experiments. With this real-time, large-area, high-energy X-ray imaging system, the two-phase flow was quantitatively visualized. An efficient image processing strategy was developed by combining several optimal digital image-processing algorithms into a software computational tool written in MATLAB called T-XIP. Time-dependent heat transfer-related variables such as bubble volumes and velocities, were determined. Finally, an error analysis associated with these measurements

  4. Heat transfer characteristics of a direct contact heat exchanger

    International Nuclear Information System (INIS)

    Kinoshita, I.; Nishi, Y.

    1993-01-01

    As a first step for development of a direct contact steam generator for FBRs, fundamental heat transfer characteristics of a liquid-liquid contact heat exchanger were evaluated by heat transfer experiment with low melting point alloy and water. Distinctive characteristics of direct contact heat transfer with liquid metal and water was obtained. (author)

  5. Real time optimization of solar powered direct contact membrane distillation based on multivariable extremum seeking

    KAUST Repository

    Karam, Ayman M.; Laleg-Kirati, Taous-Meriem

    2015-01-01

    This paper presents a real time optimization scheme for a solar powered direct contact membrane distillation (DCMD) water desalination system. The sun and weather conditions vary and are inconsistent throughout the day. Therefore, the solar powered DCMD feed inlet temperature is never constant, which influences the distilled water flux. The problem of DCMD process optimization has not been studied enough. In this work, the response of the process under various feed inlet temperatures is investigated, which demonstrates the need for an optimal controller. To address this issue, we propose a multivariable Newton-based extremum seeking controller which optimizes the inlet feed and permeate mass flow rates as the feed inlet temperature varies. Results are presented and discussed for a realistic temperature profile.

  6. Real time optimization of solar powered direct contact membrane distillation based on multivariable extremum seeking

    KAUST Repository

    Karam, Ayman M.

    2015-09-21

    This paper presents a real time optimization scheme for a solar powered direct contact membrane distillation (DCMD) water desalination system. The sun and weather conditions vary and are inconsistent throughout the day. Therefore, the solar powered DCMD feed inlet temperature is never constant, which influences the distilled water flux. The problem of DCMD process optimization has not been studied enough. In this work, the response of the process under various feed inlet temperatures is investigated, which demonstrates the need for an optimal controller. To address this issue, we propose a multivariable Newton-based extremum seeking controller which optimizes the inlet feed and permeate mass flow rates as the feed inlet temperature varies. Results are presented and discussed for a realistic temperature profile.

  7. Method and apparatus for high-efficiency direct contact condensation

    Science.gov (United States)

    Bharathan, Desikan; Parent, Yves; Hassani, A. Vahab

    1999-01-01

    A direct contact condenser having a downward vapor flow chamber and an upward vapor flow chamber, wherein each of the vapor flow chambers includes a plurality of cooling liquid supplying pipes and a vapor-liquid contact medium disposed thereunder to facilitate contact and direct heat exchange between the vapor and cooling liquid. The contact medium includes a plurality of sheets arranged to form vertical interleaved channels or passageways for the vapor and cooling liquid streams. The upward vapor flow chamber also includes a second set of cooling liquid supplying pipes disposed beneath the vapor-liquid contact medium which operate intermittently in response to a pressure differential within the upward vapor flow chamber. The condenser further includes separate wells for collecting condensate and cooling liquid from each of the vapor flow chambers. In alternate embodiments, the condenser includes a cross-current flow chamber and an upward flow chamber, a plurality of upward flow chambers, or a single upward flow chamber. The method of use of the direct contact condenser of this invention includes passing a vapor stream sequentially through the downward and upward vapor flow chambers, where the vapor is condensed as a result of heat exchange with the cooling liquid in the contact medium. The concentration of noncondensable gases in the resulting condensate-liquid mixtures can be minimized by controlling the partial pressure of the vapor, which depends in part upon the geometry of the vapor-liquid contact medium. In another aspect of this invention, the physical and chemical performance of a direct contact condenser can be predicted based on the vapor and coolant compositions, the condensation conditions. and the geometric properties of the contact medium.

  8. Direct measurement of graphene contact resistivity to pre-deposited metal in buried contact test structure

    KAUST Repository

    Qaisi, Ramy M.; Smith, Casey; Ghoneim, Mohamed T.; Yu, Qingkai; Hussain, Muhammad Mustafa

    2013-01-01

    We demonstrate a buried contact based novel test structure for direct contact resistivity measurement of graphene-metal interfaces. We also observe excellent contact resistivity 1 μO-cm2 without any additional surface modification suggesting that the intrinsic Au-graphene contact is sufficient for achieving devices with low contact resistance. The chemical mechanical polishing less test structure and data described herein highlights an ideal methodology for systematic screening and engineering of graphene-metal contact resistivity to enable low power high speed carbon electronics. © 2013 IEEE.

  9. Direct measurement of graphene contact resistivity to pre-deposited metal in buried contact test structure

    KAUST Repository

    Qaisi, Ramy M.

    2013-08-01

    We demonstrate a buried contact based novel test structure for direct contact resistivity measurement of graphene-metal interfaces. We also observe excellent contact resistivity 1 μO-cm2 without any additional surface modification suggesting that the intrinsic Au-graphene contact is sufficient for achieving devices with low contact resistance. The chemical mechanical polishing less test structure and data described herein highlights an ideal methodology for systematic screening and engineering of graphene-metal contact resistivity to enable low power high speed carbon electronics. © 2013 IEEE.

  10. A review of micro-contact physics, materials, and failure mechanisms in direct-contact RF MEMS switches

    International Nuclear Information System (INIS)

    Basu, A; Adams, G G; McGruer, N E

    2016-01-01

    Direct contact, ohmic MEMS switches for RF applications have several advantages over other conventional switching devices. Advantages include lower insertion loss, higher isolation, and better switching figure-of-merit (cut-off frequency). The most important aspect of a direct-contact RF MEMS switch is the metal microcontact which can dictate the lifetime and reliability of the switch. Therefore, an understanding of contact reliability is essential for developing robust MEMS switches. This paper discusses and reviews the most important work done over the past couple of decades toward understanding ohmic micro-contacts. We initially discuss the contact mechanics and multi-physics models for studying Hertzian and multi-asperity contacts. We follow this with a discussion on models and experiments for studying adhesion. We then discuss experimental setups and the development of contact test stations by various groups for accelerated testing of microcontacts, as well as for analysis of contact reliability issues. Subsequently, we analyze a number of material transfer mechanisms in microcontacts under hot and cold switching conditions. We finally review the material properties that can help determine the selection of contact materials. A trade-off between contact resistance and high reliability is almost always necessary during selection of contact material; this paper discusses how the choice of materials can help address such trade-offs. (paper)

  11. Transient direct-contact condensation on liquid droplets

    International Nuclear Information System (INIS)

    Pasamehmetoglu, K.O.; Nelson, R.A.

    1987-01-01

    In this paper, direct-contact condensation on subcooled liquid droplets is studied in two parts. In the first part, simple design correlations for the condensation in a steady environment are developed based upon a conduction model. These correlations include the convective heat-transfer coefficient, condensation rate, total condensation, and the droplet-thermalization time. In the second part of the paper, the effect of a time-dependent saturation temperature on the condensation process is investigated. A rapid decrease in saturation temperature is typical of condensation environments in which the steam-supply rate is limited and condensation-induced depressurization becomes important. Design correlations are developed for condensation in an environment in which the saturation temperature decreases linearly with time. These correlations are graphically compared to the design correlations of the first part through a quasi-steady approach. The error associated with this approach is quantified as a function of the rate of change of the saturation temperature

  12. Sibling Relation, Ethnic Prejudice, Direct and Indirect Contact: There is a Connection?

    Directory of Open Access Journals (Sweden)

    Sara Alfieri

    2015-11-01

    Full Text Available The literature on the socialisation of prejudice has concentrated on “vertical” processes (from parents to children, ignoring siblings’ contribution. This work aims to investigate the effect of contact (direct or indirect with the outgroup that young people experience a directly or b indirectly through older or younger siblings’ friendships. Our hypotheses are a that young people with friends in the outgroup will report lower prejudice levels (direct contact, as will young people who have older or younger siblings with friends in the outgroup (indirect contact; b that other forms of contact such as having classmates/coworkers, neighbours, or employees are not effective in reducing either direct or indirect prejudice. 88 sibling dyads were administered the blatant and subtle prejudice questionnaire (Pettigrew & Meertens, 1995 and some ad hoc items aimed at investigating the typology of the contact experienced. The analysis of mixed ANOVA reveals that the first hypothesis was partially confirmed in that prejudice (subtle for the younger sibling and blatant for the older one decreases in a statistically significant way only when there is the co-presence of direct and indirect contact. The second hypothesis is fully confirmed as no statistically significant differences emerged between the groups.

  13. Sibling Relation, Ethnic Prejudice, Direct and Indirect Contact: There is a Connection?

    Science.gov (United States)

    Alfieri, Sara; Marta, Elena

    2015-01-01

    The literature on the socialisation of prejudice has concentrated on “vertical” processes (from parents to children), ignoring siblings’ contribution. This work aims to investigate the effect of contact (direct or indirect) with the outgroup that young people experience a) directly or b) indirectly through older or younger siblings’ friendships. Our hypotheses are a) that young people with friends in the outgroup will report lower prejudice levels (direct contact), as will young people who have older or younger siblings with friends in the outgroup (indirect contact); b) that other forms of contact such as having classmates/coworkers, neighbours, or employees are not effective in reducing either direct or indirect prejudice. 88 sibling dyads were administered the blatant and subtle prejudice questionnaire (Pettigrew & Meertens, 1995) and some ad hoc items aimed at investigating the typology of the contact experienced. The analysis of mixed ANOVA reveals that the first hypothesis was partially confirmed in that prejudice (subtle for the younger sibling and blatant for the older one) decreases in a statistically significant way only when there is the co-presence of direct and indirect contact. The second hypothesis is fully confirmed as no statistically significant differences emerged between the groups. PMID:27247684

  14. Geysers advanced direct contact condenser research

    Energy Technology Data Exchange (ETDEWEB)

    Henderson, J.; Bahning, T.; Bharathan, D.

    1997-12-31

    The first geothermal application of the Advanced Direct Contact Condenser (ADCC) technology developed by the National Renewable Energy Laboratory (NREL) is now operational and is being tested at The Geysers Power Plant Unit 11. This major research effort is being supported through the combined efforts of NREL, The Department of Energy (DOE), and Pacific Gas and Electric (PG&E). NREL and PG&E have entered into a Cooperative Research And Development Agreement (CRADA) for a project to improve the direct-contact condenser performance at The Geysers Power Plant. This project is the first geothermal adaptation of an advanced condenser design developed for the Ocean Thermal Energy Conversion (OTEC) systems. PG&E expects this technology to improve power plant performance and to help extend the life of the steam field by using steam more efficiently. In accordance with the CRADA, no money is transferred between the contracting parties. In this case the Department of Energy is funding NREL for their efforts in this project and PG&E is contributing funds in kind. Successful application of this technology at The Geysers will provide a basis for NREL to continue to develop this technology for other geothermal and fossil power plant systems.

  15. Evidence for transmission of bluetongue virus serotype 26 through direct contact.

    Directory of Open Access Journals (Sweden)

    Carrie Batten

    Full Text Available The aim of this study was to assess the mechanisms of transmission of bluetongue virus serotype 26 (BTV-26 in goats. A previous study, which investigated the pathogenicity and infection kinetics of BTV-26 in goats, unexpectedly revealed that one control goat may have been infected through a direct contact transmission route. To investigate the transmission mechanisms of BTV-26 in more detail an experimental infection study was carried out in which three goats were infected with BTV-26, three goats were kept uninfected, but were housed in direct contact with the infected goats, and an additional four goats were kept in indirect contact separated from infected goats by metal gates. This barrier allowed the goats to have occasional face-to-face contact in the same airspace, but feeding, watering, sampling and environmental cleaning was carried out separately. The three experimentally infected goats did not show clinical signs of BTV, however high levels of viral RNA were detected and virus was isolated from their blood. At 21 dpi viral RNA was detected in, and virus was isolated from the blood of the three direct contact goats, which also seroconverted. The four indirect barrier contact goats remained uninfected throughout the duration of the experiment. In order to assess replication in a laboratory model species of Culicoides biting midge, more than 300 Culicoides sonorensis were fed a BTV-26 spiked blood meal and incubated for 7 days. The dissemination of BTV-26 in individual C. sonorensis was inferred from the quantity of virus RNA and indicated that none of the insects processed at day 7 possessed transmissible infections. This study shows that BTV-26 is easily transmitted through direct contact transmission between goats, and the strain does not seem to replicate in C. sonorensis midges using standard incubation conditions.

  16. Time domain contact model for tyre/road interaction including nonlinear contact stiffness due to small-scale roughness

    Science.gov (United States)

    Andersson, P. B. U.; Kropp, W.

    2008-11-01

    Rolling resistance, traction, wear, excitation of vibrations, and noise generation are all attributes to consider in optimisation of the interaction between automotive tyres and wearing courses of roads. The key to understand and describe the interaction is to include a wide range of length scales in the description of the contact geometry. This means including scales on the order of micrometres that have been neglected in previous tyre/road interaction models. A time domain contact model for the tyre/road interaction that includes interfacial details is presented. The contact geometry is discretised into multiple elements forming pairs of matching points. The dynamic response of the tyre is calculated by convolving the contact forces with pre-calculated Green's functions. The smaller-length scales are included by using constitutive interfacial relations, i.e. by using nonlinear contact springs, for each pair of contact elements. The method is presented for normal (out-of-plane) contact and a method for assessing the stiffness of the nonlinear springs based on detailed geometry and elastic data of the tread is suggested. The governing equations of the nonlinear contact problem are solved with the Newton-Raphson iterative scheme. Relations between force, indentation, and contact stiffness are calculated for a single tread block in contact with a road surface. The calculated results have the same character as results from measurements found in literature. Comparison to traditional contact formulations shows that the effect of the small-scale roughness is large; the contact stiffness is only up to half of the stiffness that would result if contact is made over the whole element directly to the bulk of the tread. It is concluded that the suggested contact formulation is a suitable model to include more details of the contact interface. Further, the presented result for the tread block in contact with the road is a suitable input for a global tyre/road interaction model

  17. Investigation of force, contact area, and dwell time in finger-tapping tasks on membrane touch interface.

    Science.gov (United States)

    Liu, Na; Yu, Ruifeng

    2018-06-01

    This study aimed to determine the touch characteristics during tapping tasks on membrane touch interface and investigate the effects of posture and gender on touch characteristics variables. One hundred participants tapped digits displayed on a membrane touch interface on sitting and standing positions using all fingers of the dominant hand. Touch characteristics measures included average force, contact area, and dwell time. Across fingers and postures, males exerted larger force and contact area than females, but similar dwell time. Across genders and postures, thumb exerted the largest force and the force of the other four fingers showed no significant difference. The contact area of the thumb was the largest, whereas that of the little finger was the smallest; the dwell time of the thumb was the longest, whereas that of the middle finger was the shortest. Relationships among finger sizes, gender, posture and touch characteristics were proposed. The findings helped direct membrane touch interface design for digital and numerical control products from hardware and software perspectives. Practitioner Summary: This study measured force, contact area, and dwell time in tapping tasks on membrane touch interface and examined effects of gender and posture on force, contact area, and dwell time. The findings will direct membrane touch interface design for digital and numerical control products from hardware and software perspectives.

  18. Workshop on Direct Contact Heat Transfer at the Solar Energy Research Institute

    CERN Document Server

    Boehm, R

    1988-01-01

    to increase the use of direct contact processes, the National Science Foundation sup­ ported a workshop on direct contact heat transfer at the Solar Energy Research Insti­ tute in the summer of 1985. We served as organizers for this workshop, which em­ phasized an area of thermal engineering that, in our opinion, has great promise for the future, but has not yet reached the point of wide-spread commercial application. Hence, a summary of the state of knowledge at this point is timely. The workshop had a dual objective: 1. To summarize the current state of knowledge in such a form that industrial practi­ tioners can make use of the available information. 2. To indicate the research and development needed to advance the state-of-the-art, indicating not only what kind of research is needed, but also the industrial poten­ tial that could be realized if the information to be obtained through the proposed research activities were available.

  19. Feasibility study on applicability of direct contact heat transfer SGs or FBRs

    International Nuclear Information System (INIS)

    Kinoshita, Izumi; Nishi, Yoshihisa; Furuya, Masahiro

    1997-01-01

    As a candidate of an innovative steam generator for fast breeder reactors, heat exchanger with direct contact heat transfer between melting alloy and water was proposed. The objectives of this study are to obtain the technical feasibility of this concept, to evaluate the heat transfer characteristics of direct contact heat transfer and to estimate the size and volume of this SG. Followings are main results. (1) In the case of sodium tube failure, it is considered that steam and water will not enter into the primary sodium under appropriate countermeasures. (2) Under the condition of temperature and pressure of SG for FBRs, the phenomenon such as vapor explosion is not take place in this SG concept. (3) as a result of material compatibility test and analysis, it is considered that 9Cr-1Mo steel and 21/4cr-1Mo steel will be a candidate structural material. (4) It is considered that the production of oxides by the chemical reaction between melting alloy and water is mitigated by dissolving hydrogen gas in feed water. (5) The fundamental direct contact heat transfer characteristics between a melting alloy and water is obtained in following two regions. One is the evaporating region and the other is the superheating region. The effect of the system pressure on the heat transfer characteristics and the required degree of superheat of a melting alloy above the water saturation temperature are evaluated during direct contact heat transfer experiments by injecting water into a high temperature melting alloy. (6) Due to the high heat transfer performance of direct contact heat transfer, it is found that compact steam generation section will be expected. However, because of the characteristics of direct contact heat exchanger, achievement of high efficiency was difficult. In order to make a good use of this SG concept, improvement of efficiency is necessary. (author)

  20. Direct measurement of friction of a fluctuating contact line.

    Science.gov (United States)

    Guo, Shuo; Gao, Min; Xiong, Xiaomin; Wang, Yong Jian; Wang, Xiaoping; Sheng, Ping; Tong, Penger

    2013-07-12

    We report a direct measurement of the friction coefficient of a fluctuating (and slipping) contact line using a thin vertical glass fiber of diameter d with one end glued onto a cantilever beam and the other end touching a liquid-air interface. By measuring the broadening of the resonant peak of the cantilever system with varying liquid viscosity η, we find the friction coefficient of the contact line has a universal form, ξ(c)≃0.8πdη, independent of the liquid-solid contact angle. The obtained scaling law is further supported by the numerical simulation based on the phase field model under the generalized Navier boundary conditions.

  1. Direct-Current Forced Interruption and Breaking Performance of Spiral-Type Contacts in Aero Applications

    Directory of Open Access Journals (Sweden)

    Wenlei Huo

    2017-05-01

    Full Text Available This paper analyses the transient characteristics and breaking performance of direct-current (DC forced-interruption vacuum interrupters in 270 V power-supply systems. Three stages are identified in forced interruption: the DC-arcing stage, current-commutation stage, and voltage-recovery stage. During the current-commutation stage, the reverse peak-current coefficient k, which is a key design factor, is used to calculate the rate of current at zero-crossing (di/dt. MATLAB/Simulink simulation models are established to obtain the transient characteristics influenced by the forced-commutation branch parameters and the coefficient k. To study the breaking performance of spiral-type contacts, experiments are conducted for different contact materials and arcing times for currents less than 3.5 kA. During the DC-arcing stage, a locally intensive burning arc is observed in the CuW80 contact; however, it is not observed in the CuCr50 contact. On examining the re-ignition interruption results of the CuW80 contact, the intensive burning arc is found to be positioned within a possible re-ignition region. When the arcing time is longer than 1 ms, the intensive burning arc occurs and affects the breaking performance of the spiral-type contacts. If the DC-arcing stage is prolonged, the total arcing energy increases, which leads to a lower breaking capacity.

  2. Mechatronic modeling of real-time wheel-rail contact

    CERN Document Server

    Bosso, Nicola; Gugliotta, Antonio; Somà, Aurelio

    2013-01-01

    Real-time simulations of the behaviour of a rail vehicle require realistic solutions of the wheel-rail contact problem which can work in a real-time mode. Examples of such solutions for the online mode have been well known and are implemented within standard and commercial tools for the simulation codes for rail vehicle dynamics. This book is the result of the research activities carried out by the Railway Technology Lab of the Department of Mechanical and Aerospace Engineering at Politecnico di Torino. This book presents work on the project for the development of a real-time wheel-rail contact model and provides the simulation results obtained with dSpace real-time hardware. Besides this, the implementation of the contact model for the development of a real-time model for the complex mechatronic system of a scaled test rig is presented in this book and may be useful for the further validation of the real-time contact model with experiments on a full scale test rig.

  3. Wettability and Contact Time on a Biomimetic Superhydrophobic Surface

    Science.gov (United States)

    Liang, Yunhong; Peng, Jian; Li, Xiujuan; Huang, Jubin; Qiu, Rongxian; Zhang, Zhihui; Ren, Luquan

    2017-01-01

    Inspired by the array microstructure of natural superhydrophobic surfaces (lotus leaf and cicada wing), an array microstructure was successfully constructed by high speed wire electrical discharge machining (HS-WEDM) on the surfaces of a 7075 aluminum alloy without any chemical treatment. The artificial surfaces had a high apparent contact angle of 153° ± 1° with a contact angle hysteresis less than 5° and showed a good superhydrophobic property. Wettability, contact time, and the corresponding superhydrophobic mechanism of artificial superhydrophobic surface were investigated. The results indicated that the micro-scale array microstructure was an important factor for the superhydrophobic surface, while different array microstructures exhibited different effects on the wettability and contact time of the artificial superhydrophobic surface. The length (L), interval (S), and height (H) of the array microstructure are the main influential factors on the wettability and contact time. The order of importance of these factors is H > S > L for increasing the apparent contact angle and reducing the contact time. The method, using HS-WEDM to fabricate superhydrophobic surface, is simple, low-cost, and environmentally friendly and can easily control the wettability and contact time on the artificial surfaces by changing the array microstructure. PMID:28772613

  4. Water hammers in direct contact heater systems

    International Nuclear Information System (INIS)

    Uffer, R.

    1983-01-01

    This paper discusses the causes and mitigation or prevention of water hammers occurring in direct contact heaters and their attached lines. These water hammers are generally caused by rapid pressure reductions in the heaters or by water lines not flowing full. Proper design and operating measures can prevent or mitigate water hammer occurrence. Water hammers often do not originate at the areas where damage is noted

  5. Direct contact condensation in packed beds

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yi; Klausner, James F.; Mei, Renwei; Knight, Jessica [Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611 (United States)

    2006-12-15

    A diffusion driven desalination process was recently described where a very effective direct contact condenser with a packed bed is used to condense water vapor out of an air/vapor mixture. A laboratory scale direct contact condenser has been fabricated as a twin tower structure with two stages, co-current and countercurrent. Experiments have been operated in each stage with respective saturated air inlet temperatures of 36, 40 and 43{sup o}C. The temperature and humidity data have been collected at the inlet and exit of the packed bed for different water to air mass flow ratios that vary between 0 and 2.5. A one-dimensional model based on conservation principles has been developed, which predicts the variation of temperature, humidity, and condensation rate through the condenser stages. Agreement between the model and experiments is very good. It is observed that the countercurrent flow stage condensation effectiveness is significantly higher than that for the co-current stage. The condensation heat and mass transfer rates were found to decrease when water blockages occur within the packed bed. Using high-speed digital cinematography, it was observed that this problem can occur at any operating condition, and is dependent on the packing surface wetting characteristics. This observation is used to explain the requirement for two different empirical constants, depending on packing diameter, suggested by Onda for the air side mass transfer coefficient correlation. (author)

  6. Evaluating the impact of direct and indirect contact on the mental health stigma of pharmacy students.

    Science.gov (United States)

    Nguyen, Elizabeth; Chen, Timothy F; O'Reilly, Claire L

    2012-07-01

    Contact with mental health consumers has shown to be a promising strategy to address mental health stigma, particularly in the context of pharmacy education. This research aimed to compare the effectiveness of a direct (face-to-face) contact intervention with an indirect (film based) contact intervention in reducing the mental health stigma of pharmacy students. A two-group, non-randomized, comparative study was conducted with third year pharmacy students (n = 198) allocated to the direct contact arm and fourth year pharmacy students (n = 278) allocated to the indirect contact arm. Baseline and immediate post-intervention data were collected using a validated 39 item survey instrument to assess the impact of the interventions on mental health stigma as well as attitudes towards providing mental health pharmaceutical services. Participants in the direct contact group showed a significant improvement in 37 out of 39 survey items and participants in the indirect contact group showed a significant improvement in 27 out of 39 items (P direct contact had a stronger impact than indirect contact for 22 items (P interventions was equivalent. Both indirect and direct contact may positively impact mental health stigma. While the strength of the stigma-change process may be heightened by face-to-face interactions, the largely positive impact of indirect contact suggests that stigma reduction may depend less on the medium of contact but more on the transcendent messages contributed by the consumers facilitating the contact experience.

  7. Contact Dynamics of EHL Contacts under Time Varying Conditions

    NARCIS (Netherlands)

    Venner, Cornelis H.; Popovici, G.; Wijnant, Ysbrand H.; Dalmaz, G.; Lubrecht, A.A.; Priest, M

    2004-01-01

    By means of numerical simulations of two situations with time varying operating conditions it is shown that the dynamic behaviour of Elasto-Hydrodynamically Lubricated contacts in terms of vibrations can be characterized as: Changes in the mutual approach lead to film thickness changes in the inlet

  8. The Potential Role of Direct and Indirect Contacts on Infection Spread in Dairy Farm Networks.

    Directory of Open Access Journals (Sweden)

    Gianluigi Rossi

    2017-01-01

    Full Text Available Animals' exchanges are considered the most effective route of between-farm infectious disease transmission. However, despite being often overlooked, the infection spread due to contaminated equipment, vehicles, or personnel proved to be important for several livestock epidemics. This study investigated the role of indirect contacts in a potential infection spread in the dairy farm network of the Province of Parma (Northern Italy. We built between-farm contact networks using data on cattle exchange (direct contacts, and on-farm visits by veterinarians (indirect contacts. We compared the features of the contact structures by using measures on static and temporal networks. We assessed the disease spreading potential of the direct and indirect network structures in the farm system by using data on the infection state of farms by paratuberculosis. Direct and indirect networks showed non-trivial differences with respect to connectivity, contact distribution, and super-spreaders identification. Furthermore, our analyses on paratuberculosis data suggested that the contributions of direct and indirect contacts on diseases spread are apparent at different spatial scales. Our results highlighted the potential role of indirect contacts in between-farm disease spread and underlined the need for a deeper understanding of these contacts to develop better strategies for prevention of livestock epidemics.

  9. Metronome rate and walking foot contact time in young adults.

    Science.gov (United States)

    Dickstein, Ruth; Plax, Michael

    2012-02-01

    It is assumed that when people walk guided by an audible constant rate, they match foot contact to the external pace. The purpose of this preliminary study was to test that assumption by examining the temporal relationship between audible signals generated by a metronome and foot contact time during gait. Ten healthy young women were tested in walking repetitions guided by metronome rates of 60, 110, and 150 beats/min. Metronome beats and foot contact times were collected in real time. The findings indicated that foot contact was not fully synchronized with the auditory signals; the shortest time interval between the metronome beat and foot contact time was at the prescribed rate of 60 beats/min., while the longest interval was at the rate of 150 beats/min. The correlation between left and right foot contact times was highest with the slowest rate and lowest with the fastest rate.

  10. Visualization of direct contact heat transfer between water and molten alloy by neutron radiography. 1

    International Nuclear Information System (INIS)

    Nishi, Yoshihisa; Furuya, Masahiro; Kinoshita, Izumi; Takenaka, Nobuyuki; Matsubayashi, Masahito.

    1997-01-01

    Design of an innovative Steam Generator (SG) for Liquid Metal Fast Reactors (LMFRs) using liquid-liquid direct contact heat transfer has been developing. In this concept, the SG shell is filled with a molten alloy, which is heated by primary sodium. Water is fed into the high-temperature, molten alloy, and evaporates by direct contact heating. In order to obtain the fundamental information needed to discuss the heat transfer mechanisms of direct contact between the water and molten alloy, this phenomenon was observed by neutron radiography. JRR-3M thermal neutron radiography at the Japan Atomic Energy Research Institute was used. This paper deals with the results of visualization of direct contact heat exchange in the molten alloy. (author)

  11. Experimental investigation of direct contact three phase boiling heat transfer

    International Nuclear Information System (INIS)

    Bruce, W.D.

    1981-01-01

    The system which was studied in the present work consisted of one liquid undergoing vaporization by contact with a hotter immiscible liquid. The liquids and vapor were contacted in a counterflow spray column with only differential increases in vapor quality. Experiments yielded vertical temperature profiles, flow rates of the phases, liquid holdups, pressure drops, and a characterization of flow patterns. A micro-computer was utilized for measuring temperatures in the column at the rate of 1500 to 1600 times per second at several depths. Analysis of the experimental data indicate that the maximum temperature difference between the phases is 0.5F 0 , and that a temperature crossover occurs at the lower end of the column. The heat transfer fluid undergoes flash vaporization at its inlet at the top of the column, and much of its sensible heat is tranferred to the dispersed phase near the top of the column. Temperature profiles along the length of the boiler are nearly flat, and very little heat transfer occurs in the lower part of the boiler. A chemical method was developed for measuring effective interfacial area in a direct contact boiler. The theoretical basis of the method is discussed, and physico-chemical data necessary for application of the technique are reported. Water solubility of methyl salicylate was measured as a function of temperature, and the second order reaction rate coefficient for saponification of methyl salicylate by sodium hydroxide was determined from sodium hydroxide concentration versus time data and a computer model of a well-mixed semibatch reactor. The activation energy for the reaction was found to be 9.58 kilocalories per gram mole

  12. 37 CFR 10.33 - Direct contact with prospective clients.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Direct contact with prospective clients. 10.33 Section 10.33 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND... clients. A practitioner may not solicit professional employment from a prospective client with whom the...

  13. From natural to biomimetic: The superhydrophobicity and the contact time.

    Science.gov (United States)

    Liang, Yun-Hong; Peng, Jian; Li, Xiu-Juan; Xu, Jin-Kai; Zhang, Zhi-Hui; Ren, Lu-Quan

    2016-08-01

    The superhydrophobicities and the contact time of lotus leaf and reed leaf were investigated. The results indicated that both lotus leaf and reed leaf have good superhydrophobic properties, and the water contact time was 12.7 and 14.7 ms on the surface of lotus leaf and reed leaf, respectively. Surface structure plays a key role in the different contacting times. Homogeneous distribution of papillae on the surface of lotus leaf was more helpful to reduce the contact time than anisotropic groove-shape on the surface of reed leaf. Based on the bionics coupling theory, the bionics sample possessing similar lotus-leaf-like surface structure on the aluminum alloy was designed and fabricated successfully. The water contact angle was about 153 ± 2°, sliding angle less than 5°, and the water contact time was 13.4 ms on the surface of bionics sample, which presented excellent superhydrophobic property, and achieved the aim of bionic design. Microsc. Res. Tech. 79:712-720, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Bilateral contact ground reaction forces and contact times during plyometric drop jumping.

    Science.gov (United States)

    Ball, Nick B; Stock, Christopher G; Scurr, Joanna C

    2010-10-01

    Drop jumping (DJ) is used in training programs aimed to improve lower extremity explosive power. When performing double-leg drop jumps, it is important to provide an equal stimulus to both legs to ensure balanced development of the lower legs. The aim of this study was to bilaterally analyze the ground reactions forces and temporal components of drop jumping from 3 heights. Ten recreationally active male subjects completed 3 bounce-drop jumps from 3 starting heights (0.2, 0.4, and 0.6 m). Two linked force platforms were used to record left- and right-leg peak vertical force, time to peak force, average force, ground contact time, impulse and time differential. Between-height and between-leg comparisons for each variable were made using a multivariate analysis of variance with post hoc Wilcoxon tests (p < 0.05). Results indicated that force and time variables increased as drop jump height increased (p < 0.0001). Post hoc analyses showed that at 0.2- and 0.4-m bilateral differences were present in the time to peak force, average force, and impulse. No bilateral differences for any variables were shown at 0.6-m starting height. The contact time for all jumps was <0.26 seconds. At 0.2 m, only 63% of the subjects had a starting time differential of <0.01 seconds, rising to 96.3% at 0.6 m. The results indicated that 0.6 m is the suggested drop jump height to ensure that no bilateral differences in vertical forces and temporal components occur; however, shorter contact times were found at the lower heights.

  15. Plasmonic direct writing lithography with a macroscopical contact probe

    Science.gov (United States)

    Huang, Yuerong; Liu, Ling; Wang, Changtao; Chen, Weidong; Liu, Yunyue; Li, Ling

    2018-05-01

    In this work, we design a plasmonic direct writing lithography system with a macroscopical contact probe to achieve nanometer scale spots. The probe with bowtie-shaped aperture array adopts spring hinge and beam deflection method (BDM) to realize near-field lithography. Lithography results show that a macroscopical plasmonic contact probe can achieve a patterning resolution of around 75 nm at 365 nm wavelength, and demonstrate that the lithography system is promising for practical applications due to beyond the diffraction limit, low cost, and simplification of system configuration. CST calculations provide a guide for the design of recording structure and the arrangement of placing polarizer.

  16. Electrical Thermal Network for Direct Contact Membrane Distillation Modeling and Analysis

    KAUST Repository

    Karam, Ayman M.

    2015-02-04

    Membrane distillation is an emerging water distillation technology that offers several advantages compared to conventional water desalination processes. Although progress has been made to model and understand the physics of the process, many studies are based on steady-state assumptions or are computationally not appropriate for real time control. This paper presents the derivation of a novel dynamical model, based on analogy between electrical and thermal systems, for direct contact membrane distillation (DCMD). The proposed model captures the dynamics of temperature distribution and distilled water flux. To demonstrate the adequacy of the proposed model, validation with transient and steady-state experimental data is presented.

  17. Binding Direction-Based Two-Dimensional Flattened Contact Area Computing Algorithm for Protein-Protein Interactions.

    Science.gov (United States)

    Kang, Beom Sik; Pugalendhi, GaneshKumar; Kim, Ku-Jin

    2017-10-13

    Interactions between protein molecules are essential for the assembly, function, and regulation of proteins. The contact region between two protein molecules in a protein complex is usually complementary in shape for both molecules and the area of the contact region can be used to estimate the binding strength between two molecules. Although the area is a value calculated from the three-dimensional surface, it cannot represent the three-dimensional shape of the surface. Therefore, we propose an original concept of two-dimensional contact area which provides further information such as the ruggedness of the contact region. We present a novel algorithm for calculating the binding direction between two molecules in a protein complex, and then suggest a method to compute the two-dimensional flattened area of the contact region between two molecules based on the binding direction.

  18. Binding Direction-Based Two-Dimensional Flattened Contact Area Computing Algorithm for Protein–Protein Interactions

    Directory of Open Access Journals (Sweden)

    Beom Sik Kang

    2017-10-01

    Full Text Available Interactions between protein molecules are essential for the assembly, function, and regulation of proteins. The contact region between two protein molecules in a protein complex is usually complementary in shape for both molecules and the area of the contact region can be used to estimate the binding strength between two molecules. Although the area is a value calculated from the three-dimensional surface, it cannot represent the three-dimensional shape of the surface. Therefore, we propose an original concept of two-dimensional contact area which provides further information such as the ruggedness of the contact region. We present a novel algorithm for calculating the binding direction between two molecules in a protein complex, and then suggest a method to compute the two-dimensional flattened area of the contact region between two molecules based on the binding direction.

  19. Convective heat transfer measurements in a vapour-liquid-liquid three-phase direct contact heat exchanger

    Science.gov (United States)

    Mahood, Hameed B.; Campbell, A. N.; Baqir, Ali Sh.; Sharif, A. O.; Thorpe, R. B.

    2017-12-01

    Energy usage is increasing around the world due to the continued development of technology, and population growth. Solar energy is a promising low-grade energy resource that can be harvested and utilised in different applications, such solar heater systems, which are used in both domestic and industrial settings. However, the implementation of an efficient energy conversion system or heat exchanger would enhance such low-grade energy processes. The direct contact heat exchanger could be the right choice due to its ability to efficiently transfer significant amounts of heat, simple design, and low cost. In this work, the heat transfer associated with the direct contact condensation of pentane vapour bubbles in a three-phase direct contact condenser is investigated experimentally. Such a condenser could be used in a cycle with a solar water heater and heat recovery systems. The experiments on the steady state operation of the three-phase direct contact condenser were carried out using a short Perspex tube of 70 cm in total height and an internal diameter of 4 cm. Only a height of 48 cm was active as the direct contact condenser. Pentane vapour, (the dispersed phase) with three different initial temperatures (40° C, 43.5° C and 47.5° C) was directly contacted with water (the continuous phase) at 19° C. The experimental results showed that the total heat transfer rate per unit volume along the direct contact condenser gradually decreased upon moving higher up the condenser. Additionally, the heat transfer rate increases with increasing mass flow rate ratio, but no significant effect on the heat transfer rate of varying the initial temperature of the dispersed phase was seen. Furthermore, both the outlet temperature of the continuous phase and the void fraction were positively correlated with the total heat transfer rate per unit volume, with no considerable effect of the initial temperature difference between the dispersed and continuous phases.

  20. Convective heat transfer measurements in a vapour-liquid-liquid three-phase direct contact heat exchanger

    Science.gov (United States)

    Mahood, Hameed B.; Campbell, A. N.; Baqir, Ali Sh.; Sharif, A. O.; Thorpe, R. B.

    2018-06-01

    Energy usage is increasing around the world due to the continued development of technology, and population growth. Solar energy is a promising low-grade energy resource that can be harvested and utilised in different applications, such solar heater systems, which are used in both domestic and industrial settings. However, the implementation of an efficient energy conversion system or heat exchanger would enhance such low-grade energy processes. The direct contact heat exchanger could be the right choice due to its ability to efficiently transfer significant amounts of heat, simple design, and low cost. In this work, the heat transfer associated with the direct contact condensation of pentane vapour bubbles in a three-phase direct contact condenser is investigated experimentally. Such a condenser could be used in a cycle with a solar water heater and heat recovery systems. The experiments on the steady state operation of the three-phase direct contact condenser were carried out using a short Perspex tube of 70 cm in total height and an internal diameter of 4 cm. Only a height of 48 cm was active as the direct contact condenser. Pentane vapour, (the dispersed phase) with three different initial temperatures (40° C, 43.5° C and 47.5° C) was directly contacted with water (the continuous phase) at 19° C. The experimental results showed that the total heat transfer rate per unit volume along the direct contact condenser gradually decreased upon moving higher up the condenser. Additionally, the heat transfer rate increases with increasing mass flow rate ratio, but no significant effect on the heat transfer rate of varying the initial temperature of the dispersed phase was seen. Furthermore, both the outlet temperature of the continuous phase and the void fraction were positively correlated with the total heat transfer rate per unit volume, with no considerable effect of the initial temperature difference between the dispersed and continuous phases.

  1. Renewable water: Direct contact membrane distillation coupled with solar ponds

    International Nuclear Information System (INIS)

    Suárez, Francisco; Ruskowitz, Jeffrey A.; Tyler, Scott W.; Childress, Amy E.

    2015-01-01

    Highlights: • Experimental investigation of direct contact membrane distillation driven by solar ponds. • The DCMD/SGSP system treats ∼6 times the water flow treated by an AGMD/SGSP system. • Half of the energy extracted from the SGSP was used to transport water across the membrane. • Reducing heat losses through the DCMD/SGSP system would yield higher water fluxes. - Abstract: Desalination powered by renewable energy sources is an attractive solution to address the worldwide water-shortage problem without contributing significant to greenhouse gas emissions. A promising system for renewable energy desalination is the utilization of low-temperature direct contact membrane distillation (DCMD) driven by a thermal solar energy system, such as a salt-gradient solar pond (SGSP). This investigation presents the first experimental study of fresh water production in a coupled DCMD/SGSP system. The objectives of this work are to determine the experimental fresh water production rates and the energetic requirements of the different components of the system. From the laboratory results, it was found that the coupled DCMD/SGSP system treats approximately six times the water flow treated by a similar system that consisted of an air–gap membrane distillation unit driven by an SGSP. In terms of the energetic requirements, approximately 70% of the heat extracted from the SGSP was utilized to drive thermal desalination and the rest was lost in different locations of the system. In the membrane module, only half of the useful heat was actually used to transport water across the membrane and the remainder was lost by conduction in the membrane. It was also found that by reducing heat losses throughout the system would yield higher water fluxes, pointing out the need to improve the efficiency throughout the DCMD/SGSP coupled system. Therefore, further investigation of membrane properties, insulation of the system, or optimal design of the solar pond must be addressed in

  2. Direct physical contact between intercalated cells in the distal convoluted tubule and the afferent arteriole in mouse kidneys.

    Directory of Open Access Journals (Sweden)

    Hao Ren

    Full Text Available Recent physiological studies in the kidney proposed the existence of a secondary feedback mechanism termed 'crosstalk' localized after the macula densa. This newly discovered crosstalk contact between the nephron tubule and its own afferent arteriole may potentially revolutionize our understanding of renal vascular resistance and electrolyte regulation. However, the nature of such a crosstalk mechanism is still debated due to a lack of direct and comprehensive morphological evidence. Its exact location along the nephron, its prevalence among the different types of nephrons, and the type of cells involved are yet unknown. To address these issues, computer assisted 3-dimensional nephron tracing was applied in combination with direct immunohistochemistry on plastic sections and electron microscopy. 'Random' contacts in the cortex were identified by the tracing and excluded. We investigated a total of 168 nephrons from all cortical regions. The results demonstrated that the crosstalk contact existed, and that it was only present in certain nephrons (90% of the short-looped and 75% of the long-looped nephrons. The crosstalk contacts always occurred at a specific position--the last 10% of the distal convoluted tubule. Importantly, we demonstrated, for the first time, that the cells found in the tubule wall at the contact site were always type nonA-nonB intercalated cells. In conclusion, the present work confirmed the existence of a post macula densa physical crosstalk contact.

  3. Direct physical contact between intercalated cells in the distal convoluted tubule and the afferent arteriole in mouse kidneys.

    Science.gov (United States)

    Ren, Hao; Liu, Ning-Yu; Andreasen, Arne; Thomsen, Jesper S; Cao, Liu; Christensen, Erik I; Zhai, Xiao-Yue

    2013-01-01

    Recent physiological studies in the kidney proposed the existence of a secondary feedback mechanism termed 'crosstalk' localized after the macula densa. This newly discovered crosstalk contact between the nephron tubule and its own afferent arteriole may potentially revolutionize our understanding of renal vascular resistance and electrolyte regulation. However, the nature of such a crosstalk mechanism is still debated due to a lack of direct and comprehensive morphological evidence. Its exact location along the nephron, its prevalence among the different types of nephrons, and the type of cells involved are yet unknown. To address these issues, computer assisted 3-dimensional nephron tracing was applied in combination with direct immunohistochemistry on plastic sections and electron microscopy. 'Random' contacts in the cortex were identified by the tracing and excluded. We investigated a total of 168 nephrons from all cortical regions. The results demonstrated that the crosstalk contact existed, and that it was only present in certain nephrons (90% of the short-looped and 75% of the long-looped nephrons). The crosstalk contacts always occurred at a specific position--the last 10% of the distal convoluted tubule. Importantly, we demonstrated, for the first time, that the cells found in the tubule wall at the contact site were always type nonA-nonB intercalated cells. In conclusion, the present work confirmed the existence of a post macula densa physical crosstalk contact.

  4. Direct contact heat transfer characteristics between melting alloy and water

    International Nuclear Information System (INIS)

    Kinoshita, Izumi; Nishi, Yoshihisa; Furuya, Masahiro

    1995-01-01

    As a candidate for an innovative steam generator for fast breeder reactors, a heat exchanger with direct contact heat transfer between melting alloy and water was proposed. The evaluation of heat transfer characteristics of this heat exchanger is one of the research subjects for the design and development of the steam generator. In this study, the effect of the pressure on heat transfer characteristics and the required degree of superheating of melting alloy above water saturation temperature are evaluated during the direct contact heat transfer experiment by injecting water into Wood's alloy. In the experiment, the pressure, the temperature of the Wood's alloy, the flow rate of feed water, and the depth of the feed water injection point are varied as parameters. As a result of the experiment, the product of the degree of Wood's alloy superheating above water saturation temperature and the depth of the feed water injection point is constant for each pressure. This constant increases as the pressure rises. (author)

  5. Effect of direct contact with iron on gas evolution behavior of aluminum

    International Nuclear Information System (INIS)

    Hashizume, Shuji; Matsumoto, Junko; Banba, Tsunetaka

    1998-01-01

    Dry Low-Level Radioactive Waste (LLW), incombustible solid LLW, generated from nuclear power stations is planed to be solidified with cement backfill in drums. The solidified dry LLW will be buried to shallow underground at Rokkasyo LLW Disposal Center. It is well known that corrosion of aluminum and hydrogen gas evolution occur in high pH environments such as mortar. Gas evolution from aluminum is likely to effect the leachability of solidified dry LLW with mortar. Though aluminum removal from dry LLW is planed, a small amount of aluminum will be actually included in dry LLW. Large effects of pH and temperature on corrosion rate of aluminum and gas evolution were recognized in our previous study. It was also found that 1.5 mole hydrogen gas evolves while 1 mole aluminum corrodes under 60degC. Actually aluminum in drums is likely to contact with carbon steel of which main element is iron. The gas evolution behavior of aluminum is expected to be affected by its direct contact with iron. Therefore, effect of direct contact with iron on gas evolution behavior of aluminum was studied. The corrosion rate of aluminum increased by contacting it with iron in simulating mortar environments. The amount of gas evolution from aluminum was reduced by contacting with iron. The reduction in gas evolution was considered to result from the change of cathode reaction from hydrogen evolution to oxygen reduction. When aluminum contacts with iron, the corrosion and gas evolution behavior of aluminum is significantly affected oxygen in environment. (author)

  6. Mesenchymal Stem Cells Induce Epithelial to Mesenchymal Transition in Colon Cancer Cells through Direct Cell-to-Cell Contact

    Directory of Open Access Journals (Sweden)

    Hidehiko Takigawa

    2017-05-01

    Full Text Available We previously reported that in an orthotopic nude mouse model of human colon cancer, bone marrow–derived mesenchymal stem cells (MSCs migrated to the tumor stroma and promoted tumor growth and metastasis. Here, we evaluated the proliferation and migration ability of cancer cells cocultured with MSCs to elucidate the mechanism of interaction between cancer cells and MSCs. Proliferation and migration of cancer cells increased following direct coculture with MSCs but not following indirect coculture. Thus, we hypothesized that direct contact between cancer cells and MSCs was important. We performed a microarray analysis of gene expression in KM12SM colon cancer cells directly cocultured with MSCs. Expression of epithelial-mesenchymal transition (EMT–related genes such as fibronectin (FN, SPARC, and galectin 1 was increased by direct coculture with MSCs. We also confirmed the upregulation of these genes with real-time polymerase chain reaction. Gene expression was not elevated in cancer cells indirectly cocultured with MSCs. Among the EMT-related genes upregulated by direct coculture with MSCs, we examined the immune localization of FN, a well-known EMT marker. In coculture assay in chamber slides, expression of FN was seen only at the edges of cancer clusters where cancer cells directly contacted MSCs. FN expression in cancer cells increased at the tumor periphery and invasive edge in orthotopic nude mouse tumors and human colon cancer tissues. These results suggest that MSCs induce EMT in colon cancer cells via direct cell-to-cell contact and may play an important role in colon cancer metastasis.

  7. Effect of direct and indirect contact with mental illness on dangerousness and social distance.

    Science.gov (United States)

    Lee, Minhwa; Seo, Mikyung

    2018-03-01

    This study is based on the contact hypothesis that contact with mental illness is the most effective anti-stigma strategy. This study aims to analyze which form of contact can most effectively decrease the dangerousness and social distance associated with schizophrenia, depression and alcoholism. In total, 573 Korean adults ( M age  = 43.71 years, standard deviation ( SD) = 13.41; 54.1% male, 45.9% female) were surveyed about randomly assigned vignettes of schizophrenia, depression and alcoholism. The participants were questioned on the dangerousness and social distance associated with the assigned vignette, as well as direct and indirect contact experience with the mental illness. Two-way analysis of variance (ANOVA) was used to determine the main effect and interaction effect that the type of mental illness and contact experience have on the two dependent variables (dangerousness and social distance). The findings show that the type of mental illness has a significant main effect on dangerousness and social distance, but contact type only has a significant main effect on social distance. Moreover, the two independent variables (mental illness subtype and contact experience) have an interaction effect on two dependent variables (dangerousness and social distance). Therefore, the anti-stigma effect of contact varies according to the type of mental illness. Our findings suggest that appropriate anti-stigma strategies are required for each type of mental illness. Considering that opportunities for direct contact with persons with mental illness are highly limited, it is necessary to actively utilize indirect contact.

  8. Direct contact thermoelectric generator (DCTEG): A concept for removing the contact resistance between thermoelectric modules and heat source

    International Nuclear Information System (INIS)

    Kim, Tae Young; Negash, Assmelash; Cho, Gyubaek

    2017-01-01

    Highlights: • A design concept of a direct contact thermoelectric generator (DCTEG) is proposed. • Power generation characteristics of the DCTEG on a diesel engine are examined. • Maximum power output of ∼45 W and conversion efficiency of ∼2.0% are obtained. • Effect of clearance on energy conversion of the DCTEG is numerically investigated. • A 132% increase in output power with a flush mounted configuration is obtained. - Abstract: This paper proposes the concept of a direct contact thermoelectric generator (DCTEG) to enhance the practicality and widen the application areas of thermoelectric generators (TEGs). In the DCTEG, one thermoelectric module (TEM) surface is directly exposed to a heat source, and the other surface is in direct contact with a coolant flow. The current direct-contact configuration is beneficial for system fabrication, maintenance, long-term reliability, and maximizing energy usage in cooperation with other energy systems because of its simple configuration and lack of interfaces between the TEMs and heat sources. In order to validate the proposed concept experimentally, a DCTEG was constructed by fabricating customized TEMs and exhaust gas and coolant channels with openings to mount the TEMs. A diesel engine served as a heat source by providing hot exhaust gas into the DCTEG, while the coolant (water–ethylene glycol mixture) was pumped into the coolant channels to remove heat. Based on the experimental results obtained under various engine operating conditions, the power generation of the DCTEG was characterized in the form of current–voltage and power–voltage curves. The maximum output power of 43 W and conversion efficiency of 2.0% were obtained under the highest engine load and rotation speed conditions. A series of numerical simulations was carried out to investigate the effect of the system configuration on the DCTEG power generation performance with the clearance between the TEM surfaces and exhaust gas

  9. Time-dependent contact behavior between diamond and a CNT turf

    International Nuclear Information System (INIS)

    Qiu, A; Bahr, D F; Fowler, S P; Jiao, J; Kiener, D

    2011-01-01

    The elastic and adhesive properties of nominally vertically aligned carbon nanotube (CNT) turfs have been measured using nanoindentation. The perceived stiffness of a CNT turf is dependent on the unloading rate, which decreases at slower unloading rates. Depth-controlled nanoindentation was used to examine adhesion effects. Adhesive loads between the turf and the probe tip increased as the time the tip is in contact with the turf increased. As these effects could be from either more tubes coming into contact with the tip due to relaxation and motion of CNTs relative to one another or each tube in contact increasing its adhesive behavior and sub-contact stiffness due to tube-tube interactions within the turf, electrical resistance measurements during nanoindentation were carried out. When the tip is held at a fixed nominal depth, the current remains constant while the contact load decreases, suggesting the number of tubes in contact with the tip stays constant with time while the relaxation mechanisms in the turf occur at positions lower than the contact surface. These observations, in conjunction with in situ TEM compression test of CNT arrays, are used to describe the relative effects the various length and time scales may have on the perceived properties measured during experiments, including elastic modulus and adhesion for gecko-like dry adhesives.

  10. Time-dependent contact behavior between diamond and a CNT turf

    Energy Technology Data Exchange (ETDEWEB)

    Qiu, A; Bahr, D F [School of Mechanical and Materials Engineering, Washington State University, 99164-2920 WA (United States); Fowler, S P; Jiao, J [Department of Physics, Portland State University, Portland, 97207-0751 OR (United States); Kiener, D, E-mail: anqi_qiu@wsu.edu, E-mail: dbahr@wsu.edu [Department of Materials Physics, University of Leoben, A-8700 Leoben (Austria)

    2011-07-22

    The elastic and adhesive properties of nominally vertically aligned carbon nanotube (CNT) turfs have been measured using nanoindentation. The perceived stiffness of a CNT turf is dependent on the unloading rate, which decreases at slower unloading rates. Depth-controlled nanoindentation was used to examine adhesion effects. Adhesive loads between the turf and the probe tip increased as the time the tip is in contact with the turf increased. As these effects could be from either more tubes coming into contact with the tip due to relaxation and motion of CNTs relative to one another or each tube in contact increasing its adhesive behavior and sub-contact stiffness due to tube-tube interactions within the turf, electrical resistance measurements during nanoindentation were carried out. When the tip is held at a fixed nominal depth, the current remains constant while the contact load decreases, suggesting the number of tubes in contact with the tip stays constant with time while the relaxation mechanisms in the turf occur at positions lower than the contact surface. These observations, in conjunction with in situ TEM compression test of CNT arrays, are used to describe the relative effects the various length and time scales may have on the perceived properties measured during experiments, including elastic modulus and adhesion for gecko-like dry adhesives.

  11. Field test of two high-pressure, direct-contact downhole steam generators. Volume I. Air/diesel system

    Energy Technology Data Exchange (ETDEWEB)

    Marshall, B.W.

    1983-05-01

    As a part of the Project DEEP STEAM to develop technology to more efficiently utilize steam for the recovery of heavy oil from deep reservoirs, a field test of a downhole steam generator (DSG) was performed. The DSG burned No. 2 diesel fuel in air and was a direct-contact, high pressure device which mixed the steam with the combustion products and injected the resulting mixture directly into the oil reservoir. The objectives of the test program included demonstration of long-term operation of a DSG, development of operational methods, assessment of the effects of the steam/combustion gases on the reservoir and comparison of this air/diesel DSG with an adjacent oxygen/diesel direct contact generator. Downhole operation of the air/diesel DSG was started in June 1981 and was terminated in late February 1982. During this period two units were placed downhole with the first operating for about 20 days. It was removed, the support systems were slightly modified, and the second one was operated for 106 days. During this latter interval the generator operated for 70% of the time with surface air compressor problems the primary source of the down time. Thermal contact, as evidenced by a temperature increase in the production well casing gases, and an oil production increase were measured in one of the four wells in the air/diesel pattern. Reservoir scrubbing of carbon monoxide was observed, but no conclusive data on scrubbing of SO/sub x/ and NO/sub x/ were obtained. Corrosion of the DSG combustor walls and some other parts of the downhole package were noted. Metallurgical studies have been completed and recommendations made for other materials that are expected to better withstand the downhole combustion environment. 39 figures, 8 tables.

  12. Time reversal invariance for a nonlinear scatterer exhibiting contact acoustic nonlinearity

    Science.gov (United States)

    Blanloeuil, Philippe; Rose, L. R. Francis; Veidt, Martin; Wang, Chun H.

    2018-03-01

    The time reversal invariance of an ultrasonic plane wave interacting with a contact interface characterized by a unilateral contact law is investigated analytically and numerically. It is shown analytically that despite the contact nonlinearity, the re-emission of a time reversed version of the reflected and transmitted waves can perfectly recover the original pulse shape, thereby demonstrating time reversal invariance for this type of contact acoustic nonlinearity. With the aid of finite element modelling, the time-reversal analysis is extended to finite-size nonlinear scatterers such as closed cracks. The results show that time reversal invariance holds provided that all the additional frequencies generated during the forward propagation, such as higher harmonics, sub-harmonics and zero-frequency component, are fully included in the retro-propagation. If the scattered waves are frequency filtered during receiving or transmitting, such as through the use of narrowband transducers, the recombination of the time-reversed waves will not exactly recover the original incident wave. This discrepancy due to incomplete time invariance can be exploited as a new method for characterizing damage by defining damage indices that quantify the departure from time reversal invariance. The sensitivity of these damage indices for various crack lengths and contact stress levels is investigated computationally, indicating some advantages of this narrowband approach relative to the more conventional measurement of higher harmonic amplitude, which requires broadband transducers.

  13. Performance evaluation of delefilcon a water gradient daily disposable contact lenses in first-time contact lens wearers.

    Science.gov (United States)

    Marx, Sebastian; Lauenborg, Bo; Kern, Jami R

    2018-02-06

    To evaluate the tolerability of and subject and investigator satisfaction with delefilcon A (DAILIES TOTAL1 ® ) daily disposable contact lenses in first-time contact lens wearers. This European multicenter, open-label, single-arm, two-week trial enrolled first-time contact lens wearers and fitted them with delefilcon A contact lenses. Assessments were made at dispensing and at Weeks 1 and 2. Subject-reported outcomes included comfort, quality of vision, convenience, and intent to purchase, which were ranked by agreement responses. Investigator-reported outcomes included slit-lamp biomicroscopy findings and lens fit satisfaction. Ninety-two subjects were included in the per protocol dataset. Mean scores at Weeks 1 and 2 for subject-reported quality of vision and ocular comfort were significantly higher with delefilcon A contact lenses than with the subjects' habitual spectacles during the day, at the end of the day, and overall (all p ≤ 0.02). Ninety-one percent of subjects reported that their study lenses were more comfortable than expected, 98% agreed that they were convenient to use, and 92% were interested in purchasing the lenses (all p disposable contact lenses. Copyright © 2017. Published by Elsevier Ltd.

  14. Transmission of African swine fever virus from infected pigs by direct contact and aerosol routes

    DEFF Research Database (Denmark)

    Olesen, Ann Sofie; Lohse, Louise; Boklund, Anette

    2017-01-01

    from Poland (designated here POL/2015/Podlaskie/Lindholm). In both studies, pigs were inoculated intranasally with the virus and contact pigs were exposed to the experimentally infected pigs, either directly (contact within and between pens) or by air. Pigs exposed to the virus by intranasal...... and occasionally infectious virus was found in nasal-, oral-, and rectal swabs obtained from the pigs, and ASFV DNA was detected in air samples. No anti-ASFV antibodies were detected in sera.In conclusion, the study shows that the currently circulating strain of ASFV can be efficiently transmitted via direct...... contact and by aerosols. Also, the results provide quantitative transmission parameters and knowledge of infection stages in pigs infected with this ASFV....

  15. Three-dimensional direct laser written graphitic electrical contacts to randomly distributed components

    Science.gov (United States)

    Dorin, Bryce; Parkinson, Patrick; Scully, Patricia

    2018-04-01

    The development of cost-effective electrical packaging for randomly distributed micro/nano-scale devices is a widely recognized challenge for fabrication technologies. Three-dimensional direct laser writing (DLW) has been proposed as a solution to this challenge, and has enabled the creation of rapid and low resistance graphitic wires within commercial polyimide substrates. In this work, we utilize the DLW technique to electrically contact three fully encapsulated and randomly positioned light-emitting diodes (LEDs) in a one-step process. The resolution of the contacts is in the order of 20 μ m, with an average circuit resistance of 29 ± 18 kΩ per LED contacted. The speed and simplicity of this technique is promising to meet the needs of future microelectronics and device packaging.

  16. Polyoxadiazole hollow fibers for produced water treatment by direct contact membrane distillation

    KAUST Repository

    Xu, Jingli; Srivatsa Bettahalli, N.M.; Chisca, Stefan; Khalid, Mohammed Khalil; Ghaffour, NorEddine; Vilagines, Ré gis; Nunes, Suzana Pereira

    2018-01-01

    Treatment of produced water in the petroleum industry has been a challenge worldwide. In this study, we evaluated the use of direct contact membrane distillation (DCMD) for this purpose, removing oil and dissolved elements and supplying clean water

  17. Investigation of the Dynamic Contact Angle Using a Direct Numerical Simulation Method.

    Science.gov (United States)

    Zhu, Guangpu; Yao, Jun; Zhang, Lei; Sun, Hai; Li, Aifen; Shams, Bilal

    2016-11-15

    A large amount of residual oil, which exists as isolated oil slugs, remains trapped in reservoirs after water flooding. Numerous numerical studies are performed to investigate the fundamental flow mechanism of oil slugs to improve flooding efficiency. Dynamic contact angle models are usually introduced to simulate an accurate contact angle and meniscus displacement of oil slugs under a high capillary number. Nevertheless, in the oil slug flow simulation process, it is unnecessary to introduce the dynamic contact angle model because of a negligible change in the meniscus displacement after using the dynamic contact angle model when the capillary number is small. Therefore, a critical capillary number should be introduced to judge whether the dynamic contact model should be incorporated into simulations. In this study, a direct numerical simulation method is employed to simulate the oil slug flow in a capillary tube at the pore scale. The position of the interface between water and the oil slug is determined using the phase-field method. The capacity and accuracy of the model are validated using a classical benchmark: a dynamic capillary filling process. Then, different dynamic contact angle models and the factors that affect the dynamic contact angle are analyzed. The meniscus displacements of oil slugs with a dynamic contact angle and a static contact angle (SCA) are obtained during simulations, and the relative error between them is calculated automatically. The relative error limit has been defined to be 5%, beyond which the dynamic contact angle model needs to be incorporated into the simulation to approach the realistic displacement. Thus, the desired critical capillary number can be determined. A three-dimensional universal chart of critical capillary number, which functions as static contact angle and viscosity ratio, is given to provide a guideline for oil slug simulation. Also, a fitting formula is presented for ease of use.

  18. Foot strike patterns and ground contact times during high-calibre middle-distance races.

    Science.gov (United States)

    Hayes, Phil; Caplan, Nicholas

    2012-01-01

    The aims of this study were to examine ground contact characteristics, their relationship with race performance, and the time course of any changes in ground contact time during competitive 800 m and 1500 m races. Twenty-two seeded, single-sex middle-distance races totalling 181 runners were filmed at a competitive athletics meeting. Races were filmed at 100 Hz. Ground contact time was recorded one step for each athlete, on each lap of their race. Forefoot and midfoot strikers had significantly shorter ground contact times than heel strikers. Forefoot and midfoot strikers had significantly faster average race speed than heel strikers. There were strong large correlations between ground contact time and average race speed for the women's events and men's 1500 m (r = -0.521 to -0.623; P < 0.05), whereas the men's 800 m displayed only a moderate relationship (r = -0.361; P = 0.002). For each event, ground contact time for the first lap was significantly shorter than for the last lap, which might reflect runners becoming fatigued.

  19. Space time manifolds and contact structures

    Directory of Open Access Journals (Sweden)

    K. L. Duggal

    1990-01-01

    Full Text Available A new class of contact manifolds (carring a global non-vanishing timelike vector field is introduced to establish a relation between spacetime manifolds and contact structures. We show that odd dimensional strongly causal (in particular, globally hyperbolic spacetimes can carry a regular contact structure. As examples, we present a causal spacetime with a non regular contact structure and a physical model [Gödel Universe] of Homogeneous contact manifold. Finally, we construct a model of 4-dimensional spacetime of general relativity as a contact CR-submanifold.

  20. Dynamic modeling and experimental validation for direct contact membrane distillation (DCMD) process

    KAUST Repository

    Eleiwi, Fadi

    2016-02-01

    This work proposes a mathematical dynamic model for the direct contact membrane distillation (DCMD) process. The model is based on a 2D Advection–Diffusion Equation (ADE), which describes the heat and mass transfer mechanisms that take place inside the DCMD module. The model studies the behavior of the process in the time varying and the steady state phases, contributing to understanding the process performance, especially when it is driven by intermittent energy supply, such as the solar energy. The model is experimentally validated in the steady state phase, where the permeate flux is measured for different feed inlet temperatures and the maximum absolute error recorded is 2.78 °C. Moreover, experimental validation includes the time variation phase, where the feed inlet temperature ranges from 30 °C to 75 °C with 0.1 °C increment every 2min. The validation marks relative error to be less than 5%, which leads to a strong correlation between the model predictions and the experiments.

  1. Dynamic modeling and experimental validation for direct contact membrane distillation (DCMD) process

    KAUST Repository

    Eleiwi, Fadi; Ghaffour, NorEddine; Alsaadi, Ahmad Salem; Francis, Lijo; Laleg-Kirati, Taous-Meriem

    2016-01-01

    This work proposes a mathematical dynamic model for the direct contact membrane distillation (DCMD) process. The model is based on a 2D Advection–Diffusion Equation (ADE), which describes the heat and mass transfer mechanisms that take place inside the DCMD module. The model studies the behavior of the process in the time varying and the steady state phases, contributing to understanding the process performance, especially when it is driven by intermittent energy supply, such as the solar energy. The model is experimentally validated in the steady state phase, where the permeate flux is measured for different feed inlet temperatures and the maximum absolute error recorded is 2.78 °C. Moreover, experimental validation includes the time variation phase, where the feed inlet temperature ranges from 30 °C to 75 °C with 0.1 °C increment every 2min. The validation marks relative error to be less than 5%, which leads to a strong correlation between the model predictions and the experiments.

  2. Electrical equivalent thermal network for direct contact membrane distillation modeling and analysis

    KAUST Repository

    Karam, Ayman M.

    2016-09-19

    Membrane distillation (MD) is an emerging water desalination technology that offers several advantages compared to conventional desalination methods. Although progress has been made to model the physics of the process, there are two common limitations of existing models. Firstly, many of the models are based on the steady-state analysis of the process and secondly, some of the models are based on partial differential equations, which when discretized introduce many states which are not accessible in practice. This paper presents the derivation of a novel dynamic model, based on the analogy between electrical and thermal systems, for direct contact membrane distillation (DCMD). An analogous electrical thermal network is constructed and its elements are parameterized such that the response of the network models the DCMD process. The proposed model captures the spatial and temporal responses of the temperature distribution along the flow direction and is able to accurately predict the distilled water flux output. To demonstrate the adequacy of the proposed model, validation with time varying and steady-state experimental data is presented. (C) 2016 Elsevier Ltd. All rights reserved.

  3. Analysis and hazard evaluation of heat-transfer fluids for the direct contact cooling system

    International Nuclear Information System (INIS)

    Hong, Joo Hi; Lee, Yeon Hee; Shin, You Hwan; Karng, Sarng Woo; Kim, Seo Young; Kim, Young Gil

    2006-01-01

    This paper discusses several low-temperature heat-transfer fluids, including water-based inorganic salt, organic salt, alcohol/glycol mixtures, silicones, and halogenated hydrocarbons in order to choose the best heat-transfer fluid for the newly designed direct contact refrigeration system. So, it contains a survey on commercial products such as propylene glycol and potassium formate as newly used in super market and food processing refrigeration. The stability of commercial fluids at the working temperature of -20 .deg. C was monitored as a function of time up to two months. And organic and inorganic compositions of candidate fluids were obtained by analytical instruments such as ES, XRF, AAS, ICP-AES, GC, and GC-MS. Analysis results indicate that commercial propylene glycol is very efficient and safe heat transfer fluids for the direct cooling system with liquid phase

  4. Universal entrainment mechanism controls contact times with motile cells

    Science.gov (United States)

    Mathijssen, Arnold J. T. M.; Jeanneret, Raphaël; Polin, Marco

    2018-03-01

    Contact between particles and motile cells underpins a wide variety of biological processes, from nutrient capture and ligand binding to grazing, viral infection, and cell-cell communication. The window of opportunity for these interactions depends on the basic mechanism determining contact time, which is currently unknown. By combining experiments on three different species—Chlamydomonas reinhardtii, Tetraselmis subcordiforms, and Oxyrrhis marina—with simulations and analytical modeling, we show that the fundamental physical process regulating proximity to a swimming microorganism is hydrodynamic particle entrainment. The resulting distribution of contact times is derived within the framework of Taylor dispersion as a competition between advection by the cell surface and microparticle diffusion, and predicts the existence of an optimal tracer size that is also observed experimentally. Spatial organization of flagella, swimming speed, and swimmer and tracer size influence entrainment features and provide tradeoffs that may be tuned to optimize the estimated probabilities for microbial interactions like predation and infection.

  5. Long Spin-Relaxation Times in a Transition-Metal Atom in Direct Contact to a Metal Substrate.

    Science.gov (United States)

    Hermenau, Jan; Ternes, Markus; Steinbrecher, Manuel; Wiesendanger, Roland; Wiebe, Jens

    2018-03-14

    Long spin-relaxation times are a prerequisite for the use of spins in data storage or nanospintronics technologies. An atomic-scale solid-state realization of such a system is the spin of a transition-metal atom adsorbed on a suitable substrate. For the case of a metallic substrate, which enables the direct addressing of the spin by conduction electrons, the experimentally measured lifetimes reported to date are on the order of only hundreds of femtoseconds. Here, we show that the spin states of iron atoms adsorbed directly on a conductive platinum substrate have a surprisingly long spin-relaxation time in the nanosecond regime, which is comparable to that of a transition metal atom decoupled from the substrate electrons by a thin decoupling layer. The combination of long spin-relaxation times and strong coupling to conduction electrons implies the possibility to use flexible coupling schemes to process the spin information.

  6. Electrokinetic desalination of protruded areas of stone avoiding the direct contact with electrodes

    DEFF Research Database (Denmark)

    Feijoo, J.; Matyscák, O.; Ottosen, Lisbeth M.

    2017-01-01

    of the sandstone highly contaminated with salts. Therefore, these results confirmed that it was possible to desalinate the sandstone using electrokinetic methods without the need to put in contact the affected areas with the equipment, reducing the possibility of altering it by manipulation.......Soluble salts are considered one of the main deterioration factors of porous building materials such as rocks, bricks or granites. The desalination treatments currently used in order to mitigate this alteration process are usually applied directly on the affected areas, which have often a low...... degree of cohesion precisely due to the deteriorating effect of the salts. The present study aimed to investigate the evaluation of a new approach based on electrokinetic techniques to desalinate rocks in monuments, specifically to desalinate carved reliefs. The procedure avoids the direct contact...

  7. Frequency and direction of competitive anger in contact sports.

    Science.gov (United States)

    Robazza, B; Bertollo, M; Bortoli, L

    2006-09-01

    The purpose of the present study was to investigate whether athletes involved in physical contact sports may interpret their feelings of anger as facilitative of performance, and to examine differences in the interpretation of anger as a function of the type of sport (team vs individual) or the competitive skill level (high vs low). A modified version of the State-Trait Anger Expression Inventory was administered to 100 Italian adult male athletes practicing rugby or individual combat sports (judo, freestyle wrestling, or Greco-Roman wrestling). The questionnaire was intended to measure the frequency and the direction (i.e., the facilitative-debilitative interpretation) of competitive anger. Many athletes engaged in contact sports tended interpret their competitive anger as facilitative of performance rather than debilitative. The type of sport and the athlete's standard level can mediate the individual's interpretation of the effects of anger symptoms upon performance. Competitors can interpret their anger as helpful to energize behavior and channel physical and mental resources for skill execution. Practitioners should assist athletes in gaining control over anger rather than attempting to suppress it.

  8. FreeContact: fast and free software for protein contact prediction from residue co-evolution.

    Science.gov (United States)

    Kaján, László; Hopf, Thomas A; Kalaš, Matúš; Marks, Debora S; Rost, Burkhard

    2014-03-26

    20 years of improved technology and growing sequences now renders residue-residue contact constraints in large protein families through correlated mutations accurate enough to drive de novo predictions of protein three-dimensional structure. The method EVfold broke new ground using mean-field Direct Coupling Analysis (EVfold-mfDCA); the method PSICOV applied a related concept by estimating a sparse inverse covariance matrix. Both methods (EVfold-mfDCA and PSICOV) are publicly available, but both require too much CPU time for interactive applications. On top, EVfold-mfDCA depends on proprietary software. Here, we present FreeContact, a fast, open source implementation of EVfold-mfDCA and PSICOV. On a test set of 140 proteins, FreeContact was almost eight times faster than PSICOV without decreasing prediction performance. The EVfold-mfDCA implementation of FreeContact was over 220 times faster than PSICOV with negligible performance decrease. EVfold-mfDCA was unavailable for testing due to its dependency on proprietary software. FreeContact is implemented as the free C++ library "libfreecontact", complete with command line tool "freecontact", as well as Perl and Python modules. All components are available as Debian packages. FreeContact supports the BioXSD format for interoperability. FreeContact provides the opportunity to compute reliable contact predictions in any environment (desktop or cloud).

  9. Contact frequency, travel time, and travel costs for patients with rheumatoid arthritis.

    Science.gov (United States)

    Sørensen, Jan; Linde, Louise; Hetland, Merete Lund

    2014-01-01

    Objectives. To investigate travel time, and travel cost related to contacts with health care providers for patients with rheumatoid arthritis (RA) during a three-month period. Methods. Patient-reported travel time and travel cost were obtained from 2847 patients with RA. Eleven outpatient clinics across Denmark recruited patients to the study. Data collected included frequency, travel time and travel costs for contacts at rheumatology outpatient clinics, other outpatient clinics, general practitioners, privately practicing medical specialists, inpatient hospitals and accident and emergency departments. Results. Over a 3-month period, patients with RA had on average 4.4 (sd 5.7) contacts with health care providers, of which 2.8 (sd 4.0) contacts were with rheumatology outpatient clinics. Private car and public travel were the most frequent modes of travel. The average patient spent 63 minutes and 13 € on travelling per contact, corresponding to a total of 4.6 hours and 56 € during the 3-month period. There was great variation in patient travel time and costs, but no statistically significant associations were found with clinical and sociodemographic characteristics. Conclusion. The results show that patients with RA spend private time and costs on travelling when they seek treatment. These findings are particularly important when analyzing social costs associated with RA.

  10. Effect of Ankle Joint Contact Angle and Ground Contact Time on Depth Jump Performance.

    Science.gov (United States)

    Phillips, Joshua H; Flanagan, Sean P

    2015-11-01

    Athletes often need to both jump high and get off the ground quickly, but getting off the ground quickly can decrease the vertical ground reaction force (VGRF) impulse, impeding jump height. Energy stored in the muscle-tendon complex during the stretch-shortening cycle (SSC) may mitigate the effects of short ground contact times (GCTs). To take advantage of the SSC, several coaches recommend "attacking" the ground with the foot in a dorsiflexed (DF) position at contact. However, the efficacy of this technique has not been tested. This investigation tested the hypotheses that shorter GCTs would lead to smaller vertical depth jump heights (VDJH), and that this difference could be mitigated by instructing the athletes to land in a DF as opposed to a plantar flexed (PF) foot position. Eighteen healthy junior college athletes performed depth jumps from a 45-cm box onto force platforms under instruction to achieve one of the 2 objectives (maximum jump height [hmax] or minimal GCT [tmin]), with one of the 2 foot conditions (DF or PF). These variations created 4 distinct jump conditions: DF-hmax, DF-tmin, PF-hmax, and PF-tmin. For all variables examined, there were no significant interactions. For all 4 conditions, the ankle was PF during landing, but the DF condition was 28.87% less PF than the PF condition. The tmin conditions had a 23.48% shorter GCT than hmax. There were no significant main effects for jump height. The peak impact force for tmin was 22.14% greater than hmax and 19.11% greater for DF compared with PF conditions. A shorter GCT did not necessitate a smaller jump height, and a less PF foot did not lead to improvements in jump height or contact time during a depth jump from a 45-cm box. The same jump height was attained in less PF and shorter GCT conditions by larger impact forces. To decrease contact time while maintaining jump height, athletes should be instructed to "get off the ground as fast as possible." This cue seems to be more important than foot

  11. Clonogenic growth of human breast cancer cells co-cultured in direct contact with serum-activated fibroblasts

    International Nuclear Information System (INIS)

    Samoszuk, Michael; Tan, Jenny; Chorn, Guillaume

    2005-01-01

    Accumulating evidence suggests that fibroblasts play a pivotal role in promoting the growth of breast cancer cells. The objective of the present study was to characterize and validate an in vitro model of the interaction between small numbers of human breast cancer cells and human fibroblasts. We measured the clonogenic growth of small numbers of human breast cancer cells co-cultured in direct contact with serum-activated, normal human fibroblasts. Using DNA microarrays, we also characterized the gene expression profile of the serum-activated fibroblasts. In order to validate the in vivo relevance of our experiments, we then analyzed clinical samples of metastatic breast cancer for the presence of myofibroblasts expressing α-smooth muscle actin. Clonogenic growth of human breast cancer cells obtained directly from in situ and invasive tumors was dramatically and consistently enhanced when the tumor cells were co-cultured in direct contact with serum-activated fibroblasts. This effect was abolished when the cells were co-cultured in transwells separated by permeable inserts. The fibroblasts in our experimental model exhibited a gene expression signature characteristic of 'serum response' (i.e. myofibroblasts). Immunostaining of human samples of metastatic breast cancer tissue confirmed that myofibroblasts are in direct contact with breast cancer cells. Serum-activated fibroblasts promote the clonogenic growth of human breast cancer cells in vitro through a mechanism that involves direct physical contact between the cells. This model shares many important molecular and phenotypic similarities with the fibroblasts that are naturally found in breast cancers

  12. Directly Printable Flexible Strain Sensors for Bending and Contact Feedback of Soft Actuators

    Directory of Open Access Journals (Sweden)

    Khaled Elgeneidy

    2018-02-01

    Full Text Available This paper presents a fully printable sensorized bending actuator that can be calibrated to provide reliable bending feedback and simple contact detection. A soft bending actuator following a pleated morphology, as well as a flexible resistive strain sensor, were directly 3D printed using easily accessible FDM printer hardware with a dual-extrusion tool head. The flexible sensor was directly welded to the bending actuator’s body and systematically tested to characterize and evaluate its response under variable input pressure. A signal conditioning circuit was developed to enhance the quality of the sensory feedback, and flexible conductive threads were used for wiring. The sensorized actuator’s response was then calibrated using a vision system to convert the sensory readings to real bending angle values. The empirical relationship was derived using linear regression and validated at untrained input conditions to evaluate its accuracy. Furthermore, the sensorized actuator was tested in a constrained setup that prevents bending, to evaluate the potential of using the same sensor for simple contact detection by comparing the constrained and free-bending responses at the same input pressures. The results of this work demonstrated how a dual-extrusion FDM printing process can be tuned to directly print highly customizable flexible strain sensors that were able to provide reliable bending feedback and basic contact detection. The addition of such sensing capability to bending actuators enhances their functionality and reliability for applications such as controlled soft grasping, flexible wearables, and haptic devices.

  13. Transport phenomena and fouling in vacuum enhanced direct contact membrane distillation: Experimental and modelling

    KAUST Repository

    Naidu, Gayathri

    2016-08-27

    The application of vacuum to direct contact membrane distillation (vacuum enhanced direct contact membrane distillation, V-DCMD) removed condensable gasses and reduced partial pressure in the membrane pores, achieving 37.6% higher flux than DCMD at the same feed temperature. Transfer mechanism and temperature distribution profile in V-DCMD were studied. The empirical flux decline (EFD) model represented fouling profiles of V-DCMD. In a continuous V-DCMD operation with moderate temperature (55 degrees C) and permeate pressure (300 mbar) for treating wastewater ROC, a flux of 16.0 +/- 0.3 L/m(2) h and high quality distillate were achieved with water flushing, showing the suitability of V-DCMD for ROC treatment. (C) 2016 Elsevier B.V. All rights reserved.

  14. Transport phenomena and fouling in vacuum enhanced direct contact membrane distillation: Experimental and modelling

    KAUST Repository

    Naidu, Gayathri; Shim, Wang Geun; Jeong, Sanghyun; Choi, YoungKwon; Ghaffour, NorEddine; Vigneswaran, Saravanamuthu

    2016-01-01

    The application of vacuum to direct contact membrane distillation (vacuum enhanced direct contact membrane distillation, V-DCMD) removed condensable gasses and reduced partial pressure in the membrane pores, achieving 37.6% higher flux than DCMD at the same feed temperature. Transfer mechanism and temperature distribution profile in V-DCMD were studied. The empirical flux decline (EFD) model represented fouling profiles of V-DCMD. In a continuous V-DCMD operation with moderate temperature (55 degrees C) and permeate pressure (300 mbar) for treating wastewater ROC, a flux of 16.0 +/- 0.3 L/m(2) h and high quality distillate were achieved with water flushing, showing the suitability of V-DCMD for ROC treatment. (C) 2016 Elsevier B.V. All rights reserved.

  15. Contact Frequency, Travel Time, and Travel Costs for Patients with Rheumatoid Arthritis

    Directory of Open Access Journals (Sweden)

    Jan Sørensen

    2014-01-01

    Full Text Available Objectives. To investigate travel time, and travel cost related to contacts with health care providers for patients with rheumatoid arthritis (RA during a three-month period. Methods. Patient-reported travel time and travel cost were obtained from 2847 patients with RA. Eleven outpatient clinics across Denmark recruited patients to the study. Data collected included frequency, travel time and travel costs for contacts at rheumatology outpatient clinics, other outpatient clinics, general practitioners, privately practicing medical specialists, inpatient hospitals and accident and emergency departments. Results. Over a 3-month period, patients with RA had on average 4.4 (sd 5.7 contacts with health care providers, of which 2.8 (sd 4.0 contacts were with rheumatology outpatient clinics. Private car and public travel were the most frequent modes of travel. The average patient spent 63 minutes and 13 € on travelling per contact, corresponding to a total of 4.6 hours and 56 € during the 3-month period. There was great variation in patient travel time and costs, but no statistically significant associations were found with clinical and sociodemographic characteristics. Conclusion. The results show that patients with RA spend private time and costs on travelling when they seek treatment. These findings are particularly important when analyzing social costs associated with RA.

  16. Fabrication of bioinspired composite nanofiber membranes with robust superhydrophobicity for direct contact membrane distillation.

    Science.gov (United States)

    Liao, Yuan; Wang, Rong; Fane, Anthony G

    2014-06-03

    The practical application of membrane distillation (MD) for water purification is hindered by the absence of desirable membranes that can fulfill the special requirements of the MD process. Compared to the membranes fabricated by other methods, nanofiber membranes produced by electrospinning are of great interest due to their high porosity, low tortuosity, large surface pore size, and high surface hydrophobicity. However, the stable performance of the nanofiber membranes in the MD process is still unsatisfactory. Inspired by the unique structure of the lotus leaf, this study aimed to develop a strategy to construct superhydrophobic composite nanofiber membranes with robust superhydrophobicity and high porosity suitable for use in MD. The newly developed membrane consists of a superhydrophobic silica-PVDF composite selective skin formed on a polyvinylidene fluoride (PVDF) porous nanofiber scaffold via electrospinning. This fabrication method could be easily scaled up due to its simple preparation procedures. The effects of silica diameter and concentration on membrane contact angle, sliding angle, and MD performance were investigated thoroughly. For the first time, the direct contact membrane distillation (DCMD) tests demonstrate that the newly developed membranes are able to present stable high performance over 50 h of testing time, and the superhydrophobic selective layer exhibits excellent durability in ultrasonic treatment and a continuous DCMD test. It is believed that this novel design strategy has great potential for MD membrane fabrication.

  17. Contact Frequency, Travel Time, and Travel Costs for Patients with Rheumatoid Arthritis

    OpenAIRE

    Sørensen, Jan; Linde, Louise; Hetland, Merete Lund

    2014-01-01

    Objectives. To investigate travel time, and travel cost related to contacts with health care providers for patients with rheumatoid arthritis (RA) during a three-month period. Methods. Patient-reported travel time and travel cost were obtained from 2847 patients with RA. Eleven outpatient clinics across Denmark recruited patients to the study. Data collected included frequency, travel time and travel costs for contacts at rheumatology outpatient clinics, other outpatient clinics, general prac...

  18. Contact frequency, travel time, and travel costs for patients with rheumatoid arthritis

    DEFF Research Database (Denmark)

    Sørensen, Jan; Linde, Louise; Hetland, Merete Lund

    2014-01-01

    Objectives. To investigate travel time, and travel cost related to contacts with health care providers for patients with rheumatoid arthritis (RA) during a three-month period. Methods. Patient-reported travel time and travel cost were obtained from 2847 patients with RA. Eleven outpatient clinics...... across Denmark recruited patients to the study. Data collected included frequency, travel time and travel costs for contacts at rheumatology outpatient clinics, other outpatient clinics, general practitioners, privately practicing medical specialists, inpatient hospitals and accident and emergency...... and 13 € on travelling per contact, corresponding to a total of 4.6 hours and 56 € during the 3-month period. There was great variation in patient travel time and costs, but no statistically significant associations were found with clinical and sociodemographic characteristics. Conclusion. The results...

  19. Disinfection Contact Time study plan (100-N Area tracer protocol). Revision 1

    International Nuclear Information System (INIS)

    Kretzschmar, S.P.; Bedi, G.S.; Martinez, P.; Ervin, K.

    1996-07-01

    Bechtel Hanford, Inc. will prepare an Engineering Tracer Study Protocol for the determination of contact time for the disinfection process at Group A Non-transient Non-community water treatment plant for the 100-N Water Plant at the Hanford Site in Richland, Washington. Included in this report are the results of a study that determine the actual detention time within the plant clearwell, and thus the disinfection contact time at several clearwell effluent flow rates

  20. Contact Estimation in Robot Interaction

    Directory of Open Access Journals (Sweden)

    Filippo D'Ippolito

    2014-07-01

    Full Text Available In the paper, safety issues are examined in a scenario in which a robot manipulator and a human perform the same task in the same workspace. During the task execution, the human should be able to physically interact with the robot, and in this case an estimation algorithm for both interaction forces and a contact point is proposed in order to guarantee safety conditions. The method, starting from residual joint torque estimation, allows both direct and adaptive computation of the contact point and force, based on a principle of equivalence of the contact forces. At the same time, all the unintended contacts must be avoided, and a suitable post-collision strategy is considered to move the robot away from the collision area or else to reduce impact effects. Proper experimental tests have demonstrated the applicability in practice of both the post-impact strategy and the estimation algorithms; furthermore, experiments demonstrate the different behaviour resulting from the adaptation of the contact point as opposed to direct calculation.

  1. Direct Contact Membrane Distillation of Dairy Process Streams

    Directory of Open Access Journals (Sweden)

    Mike Weeks

    2011-01-01

    Full Text Available Membrane distillation (MD was applied for the concentration of a range of dairy streams, such as whole milk, skim milk and whey. MD of a pure lactose solution was also investigated. Direct contact MD (DCMD mode experiments were carried out in continuous concentration mode, keeping the warm feed/retentate and cold permeate stream temperatures at 54 °C and 5 °C respectively. Performance in terms of flux and retention was assessed. The flux was found to decrease with an increase of dry-matter concentration in the feed. Retention of dissolved solids was found to be close to 100% and independent of the dry-matter concentration in the feed. Fourier Transform Infrared Spectroscopy (FTIR of the fouled membranes confirms organics being present in the fouling layer.

  2. 77 FR 14022 - Guidance for Industry: Testing for Salmonella Species in Human Foods and Direct-Human-Contact...

    Science.gov (United States)

    2012-03-08

    ...-contact animal foods, and the interpretation of test results, when the presence of Salmonella spp. in the... eggs) and direct-human-contact animal foods, and the interpretation of test results, when the presence... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2011-D-0091...

  3. Polyazole hollow fiber membranes for direct contact membrane distillation

    KAUST Repository

    Maab, Husnul; Alsaadi, Ahmad Salem; Francis, Lijo; Livazovic, Sara; Ghaffour, NorEddine; Amy, Gary L.; Nunes, Suzana Pereira

    2013-01-01

    Porous hollow fiber membranes were fabricated from fluorinated polyoxadiazole and polytriazole by a dry-wet spinning method for application in desalination of Red Sea water by direct contact membrane distillation (DCMD). The data were compared with commercially available hollow fiber MD membranes prepared from poly(vinylidene fluoride). The membranes were characterized by electron microscopy, liquid entry pressure (LEP), and pore diameter measurements. Finally, the hollow fiber membranes were tested for DCMD. Salt selectivity as high as 99.95% and water fluxes as high as 35 and 41 L m -2 h-1 were demonstrated, respectively, for polyoxadiazole and polytriazole hollow fiber membranes, operating at 80 C feed temperature and 20 C permeate. © 2013 American Chemical Society.

  4. Polyazole hollow fiber membranes for direct contact membrane distillation

    KAUST Repository

    Maab, Husnul

    2013-08-07

    Porous hollow fiber membranes were fabricated from fluorinated polyoxadiazole and polytriazole by a dry-wet spinning method for application in desalination of Red Sea water by direct contact membrane distillation (DCMD). The data were compared with commercially available hollow fiber MD membranes prepared from poly(vinylidene fluoride). The membranes were characterized by electron microscopy, liquid entry pressure (LEP), and pore diameter measurements. Finally, the hollow fiber membranes were tested for DCMD. Salt selectivity as high as 99.95% and water fluxes as high as 35 and 41 L m -2 h-1 were demonstrated, respectively, for polyoxadiazole and polytriazole hollow fiber membranes, operating at 80 C feed temperature and 20 C permeate. © 2013 American Chemical Society.

  5. Time Dependent Frictional Changes in Ice due to Contact Area Changes

    Science.gov (United States)

    Sevostianov, V.; Lipovsky, B. P.; Rubinstein, S.; Dillavou, S.

    2017-12-01

    Sliding processes along the ice-bed interface of Earth's great ice sheets are the largest contributor to our uncertainty in future sea level rise. Laboratory experiments that have probed sliding processes have ubiquitously shown that ice-rock interfaces strengthen while in stationary contact (Schulson and Fortt, 2013; Zoet et al., 2013; McCarthy et al., 2017). This so-called frictional ageing effect may have profound consequences for ice sheet dynamics because it introduces the possibility of basal strength hysteresis. Furthermore this effect is quite strong in ice-rock interfaces (more than an order of magnitude more pronounced than in rock-rock sliding) and can double in frictional strength in a matter of minutes, much faster than most frictional aging (Dieterich, 1972; Baumberger and Caroli, 2006). Despite this importance, the underling physics of frictional ageing of ice remain poorly understood. Here we conduct laboratory experiments to image the microscopic points of contact along an ice-glass interface. We optically measure changes in the real area of contact over time using measurements of this reflected optical light intensity. We show that contact area increases with time of stationary contact. This result suggests that thermally enhanced creep of microscopic icy contacts is responsible for the much larger frictional ageing observed in ice-rock versus rock-rock interfaces. Furthermore, this supports a more physically detailed description of the thermal dependence of basal sliding than that used in the current generation of large scale ice sheet models.

  6. Does the contact time of alginate with plaster cast influence its properties?

    Directory of Open Access Journals (Sweden)

    Mariana Marquezan

    Full Text Available The aim of this study was to verify the influence of the time of contact between alginate and gypsum after the modeling procedure on the properties of the plaster cast, such as surface detail, dimensional stability and microhardness. Thirty cylindrical specimens of orthodontic gypsum Type III were made by means of impressions of a stainless steel master model which had five reference lines in the upper surface. The samples were divided into two groups: Group 1 (G1 - with time of contact of 1 hour; and Group 2 (G2 - 12 hours of contact. All the specimens were stored up to 48 hours until they underwent laboratory testing. Surface detail and dimensional stability were tested by one calibrated examiner using a visual analysis and a profilometer (Profile Projector Nikon model 6C, Nikon Corporation, Tokyo, Japan, respectively, to evaluate the quality of reproduction of the lines and the distances between them. The microhardness was determined for each sample by making six indentations with a Vickers diamond pyramid indenter (Buehler, Lake Bluff, USA under a load of 100 gF for 15 s. The results showed significant difference (P £ 0.05 between groups in two of the three properties examined: surface detail and microhardness, which decreased as the time of contact rose. The 12-hour time of contact between alginate and the plaster cast is not recommended because it influences the quality of the plaster cast.

  7. Does the contact time of alginate with plaster cast influence its properties?

    Directory of Open Access Journals (Sweden)

    Mariana Marquezan

    2012-06-01

    Full Text Available The aim of this study was to verify the influence of the time of contact between alginate and gypsum after the modeling procedure on the properties of the plaster cast, such as surface detail, dimensional stability and microhardness. Thirty cylindrical specimens of orthodontic gypsum Type III were made by means of impressions of a stainless steel master model which had five reference lines in the upper surface. The samples were divided into two groups: Group 1 (G1 - with time of contact of 1 hour; and Group 2 (G2 - 12 hours of contact. All the specimens were stored up to 48 hours until they underwent laboratory testing. Surface detail and dimensional stability were tested by one calibrated examiner using a visual analysis and a profilometer (Profile Projector Nikon model 6C, Nikon Corporation, Tokyo, Japan, respectively, to evaluate the quality of reproduction of the lines and the distances between them. The microhardness was determined for each sample by making six indentations with a Vickers diamond pyramid indenter (Buehler, Lake Bluff, USA under a load of 100 gF for 15 s. The results showed significant difference (P £ 0.05 between groups in two of the three properties examined: surface detail and microhardness, which decreased as the time of contact rose. The 12-hour time of contact between alginate and the plaster cast is not recommended because it influences the quality of the plaster cast.

  8. Non-Invasive monitoring of diaphragmatic timing by means of surface contact sensors: An experimental study in dogs

    Directory of Open Access Journals (Sweden)

    Galdiz Batxi

    2004-09-01

    Full Text Available Abstract Background Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction. Methods Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal. Results The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively, with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively. Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98. In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests. Conclusion The technique presented in this work provides a non

  9. Direct contact membrane distillation: Capability to desalt raw water

    Directory of Open Access Journals (Sweden)

    Ali Boubakri

    2017-05-01

    Full Text Available In this work, the potentialities of membrane distillation to desalt raw waters were investigated. The experiments were performed on a direct contact membrane distillation (DCMD unit using a flat sheet polypropylene (PP membrane with a low pore size of 0.064 μm. The effect of relevant operating parameters such as transmembrane temperature difference, hydrodynamic conditions and ionic strength on permeate flux and conductivity was studied. The results indicated that a permeate flux increases with increasing transmembrane temperature difference and Reynolds number, and slightly decreases with increasing ionic strength. The permeate flux reached 4.24 L/m2 h at a temperature difference of 60 °C and Reynolds number of 3740 and ionic strength of 8.56 × 10−2 M. DCMD process using PP with low pore size membrane present a very low salt passage through the membrane which was not affected by feed concentration. DCMD process has been applied during a long period to desalt raw water without any pretreatment. For brackish water, the variation of permeate flux and conductivity were slightly changed as function of operating time. For seawater, the permeate flux decreased slightly and the permeate conductivity increased sharply in which a simple pretreatment step is recommended to ameliorate the performance of DCMD process.

  10. The effects of indirect intergroup contact on willingness to engage in direct contact with former adversary

    Czech Academy of Sciences Publication Activity Database

    Voca, S.; Graf, Sylvie

    2018-01-01

    Roč. 12, č. 1 (2018), s. 47-57 ISSN 2309-3455 R&D Projects: GA ČR(CZ) GA17-14387S Institutional support: RVO:68081740 Keywords : positive intergroup contact * negative intergroup contact * extended intergroup contact * mass-mediated intergroup contact * willingness to engage in intergroup contact * empathy * outgroup trust Subject RIV: AN - Psychology OBOR OECD: Psychology (including human - machine relations)

  11. The Setting Time of Polyether Impression Materials after Contact with Conventional and Experimental Gingival Margin Displacement Agents.

    Science.gov (United States)

    Nowakowska, Danuta; Raszewski, Zbigniew; Ziętek, Marek; Saczko, Jolanta; Kulbacka, Julita; Więckiewicz, Włodzimierz

    2018-02-01

    The compatibility of chemical gingival margin displacement agents with polyether impression materials has not been determined. The aim of this study was to evaluate the setting time of polyether impression elastomers after contact with conventional and experimental gingival displacement agents. The study compared the setting time of two polyether impression materials: medium body (Impregum Penta Soft) and light body (Impregum Garant L DuoSoft) after contact with 10 gingival displacement agents, including 5 conventional astringents (10%, 20%, and 25% aluminum chloride, 25% aluminum sulfate, and 15.5% ferric sulfate) and 5 experimental adrenergics (0.1% and 0.01% HCl-epinephrine, 0.05% HCl-tetrahydrozoline, 0.05% HCl-oxymetazoline, and 10% HCl-phenylephrine). As many as 120 specimens (60 light body and 60 medium body) were mixed with 20 μl of each of 10 gingival displacement agents, and the time to achieve maximum viscosity was measured with a viscometer. The setting times of these specimens were compared with the control group of 12 specimens, which were polymerized without contact with the displacement agents. The experiments were performed in two environments: 23°C and 37°C (± 0.1°C). Individual and average polymerization time compatibility indices (PTCI) were calculated. Data were analyzed by 2-way ANOVA (α = 0.05). The evaluated chemical displacement agents from both groups changed the setting time of light- and medium-body PE. The negative individual PTCI values achieved astringent (20% aluminum chloride) with two PE in both temperature environments. The average PTCI values of the experimental displacement agents at laboratory and intraoral temperatures were significantly higher than the conventional agents. The present findings suggest that experimental retraction agents can be recommended clinically as gingival margin displacement agents with minimal effects on the setting time of medium- and light-body polyether impression materials; however, direct

  12. Direct Laser Writing of Nanophotonic Structures on Contact Lenses.

    Science.gov (United States)

    AlQattan, Bader; Yetisen, Ali K; Butt, Haider

    2018-04-24

    Contact lenses are ubiquitous biomedical devices used for vision correction and cosmetic purposes. Their application as quantitative analytical devices is highly promising for point-of-care diagnostics. However, it is a challenge to integrate nanoscale features into commercial contact lenses for application in low-cost biosensors. A neodymium-doped yttrium aluminum garnet (Nd:YAG) laser (1064 nm, 3 ns pulse, 240 mJ) in holographic interference patterning mode was utilized to produce optical nanostructures over the surface of a hydrogel contact lens. One-dimensional (925 nm) and two-dimensional (925 nm × 925 nm) nanostructures were produced on contact lenses and analyzed by spectroscopy and angle-resolve measurements. The holographic properties of these nanostructures were tested in ambient moisture, fully hydrated, and artificial tear conditions. The measurements showed a rapid tuning of optical diffraction from these nanostructures from 41 to 48°. The nanostructures were patterned near the edges of the contact lens to avoid any interference and obstruction to the human vision. The formation of 2D nanostructures on lenses increased the diffraction efficiency by more than 10%. The versatility of the holographic laser ablation method was demonstrated by producing four different 2D nanopattern geometries on contact lenses. Hydrophobicity of the contact lens was characterized by contact angle measurements, which increased from 59.0° at pristine condition to 62.5° at post-nanofabrication. The holographic nanostructures on the contact lens were used to sense the concentration of Na + ions. Artificial tear solution was used to simulate the conditions in dry eye syndrome, and nanostructures on the contact lenses were used to detect the electrolyte concentration changes (±47 mmol L -1 ). Nanopatterns on a contact lens may be used to sense other ocular diseases in early stages at point-of-care settings.

  13. Blink patterns and lid-contact times in dry-eye and normal subjects

    Directory of Open Access Journals (Sweden)

    Ousler GW 3rd

    2014-05-01

    Full Text Available George W Ousler 3rd,1 Mark B Abelson,1,2 Patrick R Johnston,1 John Rodriguez,1 Keith Lane,1 Lisa M Smith11Ora, Andover, MA, USA; 2Department of Ophthalmology, Harvard Medical School, Boston, MA, USAPurpose: To classify blinks in dry eye and normal subjects into six subtypes, and to define the blink rate and duration within each type of blink, as well as the total lid-contact time/minute.Materials and methods: This was a single-centered, prospective, double-blind study of eleven dry-eye and ten normal subjects. Predefined subjects watched a video while blinks were recorded for 10 minutes. Partial blinks were classified by percentage closure of maximal palpebral fissure opening: 25%, 50%, 75%. Complete blinks were characterized as full (>0 seconds, extended (>0.1 seconds, or superextended (>0.5 seconds. The mean duration of each type of blink was determined and standardized per minute as total lid-contact time.Results: Total blinks observed were 4,990 (1,414 normal, 3,756 dry eye: 1,809 (50.59% partial and 1,767 (49.41% complete blinks among dry-eye subjects versus 741 (52.90% partial and 673 (47.60% complete blinks among normal subjects. Only superextended blinks of ≥0.5-second duration were significantly more frequent in dry-eye subjects than normals (2.3% versus 0.2%, respectively; P=0.023. Total contact time was seven times higher in dry-eye subjects than normals (0.565 versus 0.080 seconds, respectively; P<0.001. Isolating only extended blinks (>0.1 second, the average contact time (seconds was four times longer in dry-eye versus normal subjects (2.459 in dry eye, 0.575 in normals; P=0.003. Isolating only superextended blinks (>0.5 seconds, average contact time was also significantly different (7.134 in dry eye, 1.589 in normals; P<0.001. The contact rate for all full closures was 6.4 times longer in dry-eye (0.045 versus 0.007, P<0.001 than normal subjects.Conclusion: Dry-eye subjects spent 4.5% of a

  14. The direction of time

    CERN Document Server

    Reichenbach, Hans

    1999-01-01

    Ever a source of philosophical conjecture and debate, the concept of time represents the beating heart of physics. This final work by the distinguished physicist Hans Reichenbach represents the culmination and integration of a lifetime's philosophical contributions and inquiries into the analysis of time. The result is an outstanding overview of such qualitative, or topological, attributes of time as order and direction.Beginning with a discussion of the emotive significance of time, Reichenbach turns to an examination of the time order of mechanics, the time direction of thermodynamics and m

  15. Analysis of direct contact membrane distillation based on a lumped-parameter dynamic predictive model

    KAUST Repository

    Karam, Ayman M.; Alsaadi, Ahmad Salem; Ghaffour, NorEddine; Laleg-Kirati, Taous-Meriem

    2016-01-01

    Membrane distillation (MD) is an emerging technology that has a great potential for sustainable water desalination. In order to pave the way for successful commercialization of MD-based water desalination techniques, adequate and accurate dynamical models of the process are essential. This paper presents the predictive capabilities of a lumped-parameter dynamic model for direct contact membrane distillation (DCMD) and discusses the results under wide range of steady-state and dynamic conditions. Unlike previous studies, the proposed model captures the time response of the spacial temperature distribution along the flow direction. It also directly solves for the local temperatures at the membrane interfaces, which allows to accurately model and calculate local flux values along with other intrinsic variables of great influence on the process, like the temperature polarization coefficient (TPC). The proposed model is based on energy and mass conservation principles and analogy between thermal and electrical systems. Experimental data was collected to validated the steady-state and dynamic responses of the model. The obtained results shows great agreement with the experimental data. The paper discusses the results of several simulations under various conditions to optimize the DCMD process efficiency and analyze its response. This demonstrates some potential applications of the proposed model to carry out scale up and design studies. © 2016

  16. Analysis of direct contact membrane distillation based on a lumped-parameter dynamic predictive model

    KAUST Repository

    Karam, Ayman M.

    2016-10-03

    Membrane distillation (MD) is an emerging technology that has a great potential for sustainable water desalination. In order to pave the way for successful commercialization of MD-based water desalination techniques, adequate and accurate dynamical models of the process are essential. This paper presents the predictive capabilities of a lumped-parameter dynamic model for direct contact membrane distillation (DCMD) and discusses the results under wide range of steady-state and dynamic conditions. Unlike previous studies, the proposed model captures the time response of the spacial temperature distribution along the flow direction. It also directly solves for the local temperatures at the membrane interfaces, which allows to accurately model and calculate local flux values along with other intrinsic variables of great influence on the process, like the temperature polarization coefficient (TPC). The proposed model is based on energy and mass conservation principles and analogy between thermal and electrical systems. Experimental data was collected to validated the steady-state and dynamic responses of the model. The obtained results shows great agreement with the experimental data. The paper discusses the results of several simulations under various conditions to optimize the DCMD process efficiency and analyze its response. This demonstrates some potential applications of the proposed model to carry out scale up and design studies. © 2016

  17. Dynamic solar-powered multi-stage direct contact membrane distillation system: Concept design, modeling and simulation

    KAUST Repository

    Lee, Jung Gil; Kim, Woo-Seung; Choi, June-Seok; Ghaffour, NorEddine; Kim, Young-Deuk

    2017-01-01

    This paper presents a theoretical analysis of the monthly average daily and hourly performances of a solar-powered multi-stage direct contact membrane distillation (SMDCMD) system with an energy recovery scheme and dynamic operating system. Mid

  18. Design, simulation and characterization of a MEMS inertia switch with flexible CNTs/Cu composite array layer between electrodes for prolonging contact time

    International Nuclear Information System (INIS)

    Wang, Yang; Yang, Zhuoqing; Xu, Qiu; Chen, Wenguo; Ding, Guifu; Zhao, Xiaolin

    2015-01-01

    This paper reports an inertia switch with a flexible carbon nanotubes/copper (CNTs/Cu) composite array layer between movable and fixed electrodes, which achieves a longer contact time compared to the traditional design using rigid-to-rigid impact between electrodes. The CNTs/Cu layer is fabricated using the composite electroplating method, and the whole device is completed by multi-layer metal electroplating based on the micro-electro-mechanical systems (MEMS) process. The dynamic responses of the designed inertia switch and the contact impact between a single CNT and a fixed electrode/another CNT have both been simulated by the ANSYS finite-element-method (FEM). It is shown that the contact time of the designed inertia switch is about 100 µs under the applied 80 g half-sine-shaped acceleration in the sensing direction. Finally, the fabricated MEMS inertia switch with the flexible CNTs/Cu composite array layer between electrodes has been evaluated by a dropping hammer system. The test contact time is about112 µs, which has a good agreement with the simulation and is much longer than that of the traditional design. (paper)

  19. Real-time simulation of contact and cutting of heterogeneous soft-tissues.

    Science.gov (United States)

    Courtecuisse, Hadrien; Allard, Jérémie; Kerfriden, Pierre; Bordas, Stéphane P A; Cotin, Stéphane; Duriez, Christian

    2014-02-01

    This paper presents a numerical method for interactive (real-time) simulations, which considerably improves the accuracy of the response of heterogeneous soft-tissue models undergoing contact, cutting and other topological changes. We provide an integrated methodology able to deal both with the ill-conditioning issues associated with material heterogeneities, contact boundary conditions which are one of the main sources of inaccuracies, and cutting which is one of the most challenging issues in interactive simulations. Our approach is based on an implicit time integration of a non-linear finite element model. To enable real-time computations, we propose a new preconditioning technique, based on an asynchronous update at low frequency. The preconditioner is not only used to improve the computation of the deformation of the tissues, but also to simulate the contact response of homogeneous and heterogeneous bodies with the same accuracy. We also address the problem of cutting the heterogeneous structures and propose a method to update the preconditioner according to the topological modifications. Finally, we apply our approach to three challenging demonstrators: (i) a simulation of cataract surgery (ii) a simulation of laparoscopic hepatectomy (iii) a brain tumor surgery. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. A Model of Direct Contact Membrane Distillation of Black Currant Juice

    DEFF Research Database (Denmark)

    Jensen, Morten Busch; Christensen, Knud Villy; Andrésen, René

    2011-01-01

    A numerical model to describe a direct contact membrane distillation proces has been developed. Said model is based on the Dusty Gas model and shell mass and energy balances over a tubular membrane module.  "The solution is applicable to laminar, incompressible and continuous flow in shell......-side spacing of tubular-type unit."  Turtuosity and porosity are characteristics of the membrane in use and have been estimated base don eksperimental studies on destillation of pure water. The fitted model shows a good fit to experimental data obtained by destillation of black currant juice....

  1. Workers' compensation loss prevention representative contact and risk of lost-time injury in construction policyholders.

    Science.gov (United States)

    Schofield, Katherine E; Alexander, Bruce H; Gerberich, Susan G; MacLehose, Richard F

    2017-09-01

    Insurance loss prevention (LP) representatives have access and contact with businesses and employees to provide targeted safety and health resources. Construction firms, especially those smaller in size, are a high-risk population. This research evaluated the association between LP rep contact and risk for lost-time injuries in construction policyholders. Workers' compensation data were utilized to track LP rep contact with policyholders and incidence of lost-time injury over time. Survival analysis with repeated events modeling calculated hazard ratios (HR) and 95% confidence intervals (CI). Compared no LP contact, one contact was associated with a 27% reduction of risk (HR=0.73, CI=0.65-0.82), two with a 41% (HR=0.59, CI=0.51-0.68), and three or more contacts with a 28% reduction of risk (HR=0.72, CI=0.65-0.81). LP reps appear to be a valuable partner in efforts to reduce injury burden. Their presence or contact with policyholders is consistent with reduction in overall incidence of lost-time injuries. Reduction in lost-time injuries, resulting in reduced workers' compensation costs for policyholders and insurance companies, builds a business-case for safety and injury prevention. LP reps are often a low or no-cost benefit for insurance policyholders and may be an important injury prevention resource for small firms and/or those with lack of safety resources and staff. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. A surface-micromachining-based inertial micro-switch with compliant cantilever beam as movable electrode for enduring high shock and prolonging contact time

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Qiu [National Key Laboratory of Science and Technology on Micro/Nano Fabrication, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China); Yang, Zhuoqing, E-mail: yzhuoqing@sjtu.edu.cn [National Key Laboratory of Science and Technology on Micro/Nano Fabrication, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China); Fu, Bo; Li, Jianhua; Wu, Hao [Huaihai Industrial Group Co., Ltd., Changzhi, Shanxi Province, 046012 (China); Zhang, Qihuan; Sun, Yunna; Ding, Guifu; Zhao, Xiaolin [National Key Laboratory of Science and Technology on Micro/Nano Fabrication, School of Electronics Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240 (China)

    2016-11-30

    Highlights: • The designed cantilever beam attached to the proof mass can endure a larger shock acceleration (∼1000 g order of magnitude) compared to those traditional designs (∼100 g order of magnitude). • Effect of the pulse width on the threshold acceleration, the response time and the contact time is investigated. • A constraint sleeve structure is introduced to lower the off-axis sensitivity. - Abstract: A novel laterally-driven inertial micro-switch with two L-shaped elastic cantilever beams as the movable electrode, which is attached to the proof mass, is proposed in this paper. The advantage of this design is that the contact time of the inertial micro-switch can be prolonged. Meanwhile, the micro-switch can withstand a higher shock than the traditional designs whose cantilever beams are attached to the fixed electrode. The designed inertial micro-switch was simulated and optimized with ANSYS software and fabricated on a quartz substrate by surface micromachining technology. The simulated result demonstrates that the threshold acceleration (a{sub ths}) under stable switch-on state is about 288 g and the contact time is about 198 μs when the pulse width of acceleration loads is 1 ms. At the same time, it indicates that the threshold acceleration, the response time and the contact time of designed micro-switch all increase with the pulse width of acceleration loads. The simulation of impact process in non-sensitive direction shows that the introduced constraint sleeve structure in the novel inertial micro-switch can lower the off-axis sensitivity. The fabricated micro-switch prototype has been tested by a standard dropping hammer system under shock accelerations with various amplitudes and pulse widths. The experimental measurements show that the contact time is about 150 μs when the threshold acceleration is about 288 g. It also indicates that the response time and the contact time both increase with the pulse width, which is consistent with the

  3. Calculation of force and time of contact formation at diffusion metal joining

    Energy Technology Data Exchange (ETDEWEB)

    Sukhanov, V E [Tsentral' nyj Nauchno-Issledovatel' skij Inst. Chernoj Metallurgii, Moscow (USSR); Grushevskij, A V [Moskovskij Stankoinstrumental' nyj Inst., Moscow (USSR); Surovtsev, A P

    1989-03-01

    An analytical model of contact for mation at diffusion joining is suggested. It is based on the introduction of a rough surface with roughnesses in the form of absolutely rigid spherical segnunts into a smooth laminar body. Mathematical expressions, permitting to calculate maximum welding force (pressure) providing close contact of the surfaces welded and time for contact formation between rough surfaces joined, are obtained. Divergence of calculational and experimental data does not exceed 20%. It is confirmed that the most intensive formation of joining occurs in the initial period of welding -the stage of formation of a physical contact, when deformation processes proceed in tensively. Finite formation of a strength joint occurs at the stage of diffusion interaction.

  4. Informing disease models with temporal and spatial contact structure among GPS-collared individuals in wild populations.

    Directory of Open Access Journals (Sweden)

    David M Williams

    Full Text Available Contacts between hosts are essential for transmission of many infectious agents. Understanding how contacts, and thus transmission rates, occur in space and time is critical to effectively responding to disease outbreaks in free-ranging animal populations. Contacts between animals in the wild are often difficult to observe or measure directly. Instead, one must infer contacts from metrics such as proximity in space and time. Our objective was to examine how contacts between white-tailed deer (Odocoileus virginianus vary in space and among seasons. We used GPS movement data from 71 deer in central New York State to quantify potential direct contacts between deer and indirect overlap in space use across time and space. Daily probabilities of direct contact decreased from winter (0.05-0.14, to low levels post-parturition through summer (0.00-0.02, and increased during the rut to winter levels. The cumulative distribution for the spatial structure of direct and indirect contact probabilities around a hypothetical point of occurrence increased rapidly with distance for deer pairs separated by 1,000 m-7,000 m. Ninety-five percent of the probabilities of direct contact occurred among deer pairs within 8,500 m of one another, and 99% within 10,900 m. Probabilities of indirect contact accumulated across greater spatial extents: 95% at 11,900 m and 99% at 49,000 m. Contacts were spatially consistent across seasons, indicating that although contact rates differ seasonally, they occur proportionally across similar landscape extents. Distributions of contact probabilities across space can inform management decisions for assessing risk and allocating resources in response.

  5. Safety design of Pb-Bi-cooled direct contact boiling water fast reactor (PBWFR)

    International Nuclear Information System (INIS)

    Takahashi, Minoru; Uchida, Shoji; Yamada, Yumi; Koyama, Kazuya

    2008-01-01

    In Pb-Bi-cooled direct contact boiling water small fast reactor (PBWFR), steam is generated by direct contact of feedwater with primary Pb-Bi coolant above the core, and Pb-Bi coolant is circulated by steam lift pump in chimneys. Safety design has been developed to show safety features of PBWFR. Negative void reactivity is inserted even if whole of the core and upper plenum are voided hypothetically by steam intrusion from above. The control rod ejection due to coolant pressure is prevented using in-vessel type control rod driving mechanism. At coolant leak from reactor vessel and feedwater pipes, Pb-Bi coolant level in the reactor vessel required for decay heat removal is kept using closed guard vessel. Dual pipes for feedwater are employed to avoid leak of water. Although there is no concern of loss of flow accident due to primary pump trip, feedwater pump trip initiates loss of coolant flow (LOF). Injection of high pressure water slows down the flow coast down of feedwater at the LOF event. The unprotected loss of flow and heat sink (ATWS) has been evaluated, which shows that the fuel temperatures are kept lower than the safety limits. (author)

  6. Fouling development in direct contact membrane distillation: Non-invasive monitoring and destructive analysis

    KAUST Repository

    Fortunato, Luca

    2017-12-26

    Fouling development in direct contact membrane distillation (DCMD) for seawater desalination was evaluated combining in-situ monitoring performed using optical coherence tomography (OCT) together with destructive techniques. The non-invasive monitoring with OCT provided a better understanding of the fouling mechanism by giving an appropriate sampling timing for the membrane autopsy. The on-line monitoring system allowed linking the flux trend with the structure of fouling deposited on the membrane surface. The water vapor flux trend was divided in three phases based on the deposition and formation of different foulants over time. The initial flux decline was due to the deposition of a 50–70 nm porous fouling layer consisting of a mixture of organic compounds and salts. Liquid chromatography with organic carbon detection (LC-OCD) analysis revealed the abundance of biopolymer in the fouling layer formed at the initial phase. In the second phase, formation of carbonate crystals on the membrane surface was observed but did not affect the flux significantly. In the last phase, the water vapor flux dropped to almost zero due to the deposition of a dense thick layer of sulfate crystals on the membrane surface.

  7. Reduction of teat skin mastitis pathogen loads: differences between strains, dips, and contact times.

    Science.gov (United States)

    Enger, B D; Fox, L K; Gay, J M; Johnson, K A

    2015-02-01

    The purpose of these experiments was to (1) assess differences in mastitis pathogen strain sensitivities to teat disinfectants (teat dips), and (2) determine the optimum time for premilking teat dips to remain in contact with teat skin to reduce pathogen loads on teat skin. Two experiments were conducted using the excised teat model. In experiment 1, the differences in mastitis pathogen strain sensitivities to 4 commercially available dips (dip A: 1% H2O2; dip B: 1% chlorine dioxide; dip C: 1% iodophor; and dip D: 0.5% iodophor) were evaluated. Four strains of 11 common mastitis pathogens (Staphylococcus aureus, Streptococcus agalactiae, Mycoplasma bovis, Streptococcus dysgalactiae, Streptococcus uberis, Escherichia coli, Staphylococcus chromogenes, Staphylococcus epidermidis, Staphylococcus hyicus, Staphylococcus xylosus, and Staphylococcus haemolyticus) were tested. In experiment 2, the percentage log reduction of mastitis pathogens (Escherichia coli, Streptococcus uberis, Streptococcus dysgalactiae, Klebsiella species, Staphylococcus chromogenes, Staphylococcus haemolyticus, Staphylococcus xylosus, and Staphylococcus epidermidis) on teat skin with 3 commercially available teat dips: dip A; dip D; and dip E: 0.25% iodophor, using dip contact times of 15, 30, and 45 s, was evaluated. Experiment 1 results indicated significant differences in strain sensitivities to dips within pathogen species: Staphylococcus aureus, Staphylococcus chromogenes, and Streptococcus uberis. Species differences were also found where Mycoplasma bovis (97.9% log reduction) was the most sensitive to tested teat dips and Staphylococcus haemolyticus (71.4% log reduction) the most resistant. Experiment 2 results indicated that contact times of 30 and 45 s were equally effective in reducing recovered bacteria for dips D and E and were also significantly more effective than a 15-s contact time. No differences were seen in recovered bacteria between tested contact times after treatment with dip

  8. Open-cycle magnetohydrodynamic power plant based upon direct-contact closed-loop high-temperature heat exchanger

    Science.gov (United States)

    Berry, G.F.; Minkov, V.; Petrick, M.

    1981-11-02

    A magnetohydrodynamic (MHD) power generating system is described in which ionized combustion gases with slag and seed are discharged from an MHD combustor and pressurized high temperature inlet air is introduced into the combustor for supporting fuel combustion at high temperatures necessary to ionize the combustion gases, and including a heat exchanger in the form of a continuous loop with a circulating heat transfer liquid such as copper oxide. The heat exchanger has an upper horizontal channel for providing direct contact between the heat transfer liquid and the combustion gases to cool the gases and condense the slag which thereupon floats on the heat transfer liquid and can be removed from the channel, and a lower horizontal channel for providing direct contact between the heat transfer liquid and pressurized air for preheating the inlet air. The system further includes a seed separator downstream of the heat exchanger.

  9. Humidification-Dehumidification (HDH) Spray Column Direct Contact Condenser Part I: Countercurrent Flow

    International Nuclear Information System (INIS)

    Karameldin, A.; Shouman, L.; Fadel, D.

    2016-01-01

    Humidification-De humidification (HDH) is a low grade energy desalination technology. Hot humid air and cooling spray water in counter current flow with direct contact is theoretically analyzed in the present work. Direct contact spray condenser is studied to obtain the effect of various parameters on its performance. A computer program describing the theoretical model is designed to solve one-dimensional differential equations by using Rung-Kutta method. The results show that the column length has a great effect on the performance of the spray condenser. At a column height of 2, 5,10, and 20 m the humidity of the outlet air decreases by 72, 89, 97, and 99% respectively. The humid air temperature has a great influence on the productivity; me an while the temperature difference between the humid air and sprayed water has less effect. A case study of a contiguous co-generation electricity and water in Nuclear Power Plants (NPP) shows that the optimal productivity by HDH is feasible and can reach more than 15 m"3 /day.m"2, enabling a total productivity that varied from 120,000 to 300,000 m"3 /day. The design curves describing the process are obtained together in addition to a formula for the optimal productivity in terms of humid air and sprayed water fluxes at different humid air temperatures is derived

  10. Humidification Dehumidification Spray Column Direct Contact Condenser Part I: Countercurrent Flow

    International Nuclear Information System (INIS)

    Shouman, L.; Karameldin, A.; Fadel, D.

    2015-01-01

    Humidification-dehumidification (HDH) is a low grade energy desalination technology. The waste heat from power plant (such NPP) can be used as heat source to preheat water (in evaporator) and air (in condenser) . Hot humid air and cooled spray water in counter current flow with direct contact is theoretically analyzing in the present work. Direct contact spray condenser is studied to provide the effect of various parameters on its performance. A computer programme describing the theoretical model is designed to solve a one-dimensional differential equations by using Rung–Kutta method. The programme predicts the droplet radius, velocity and temperature, besides, the humidity and temperature of air. The results show that, the length of column has great effect on the performance of spray condenser. At column height of 0.762, 2, 5, 10, and 20 m the humidity of the output air decreases by 50%, 72%, 89%, 97%, and 99% respectively. The condensate increases about 35% when the length increase from 5 to 10 m at ΔT = 25°C while increase only 18% at ΔT = 30°C. Also, it is found that, at ΔT = 25°C the condensate decrease from H = 10 to 5 m about 31% and increases from 10 to 20 m about 32%. While these results for ΔT = 25°C are 32% from H = 10 to 5 m and 36% from 10 to 20 m.The increase of both water and air mass fluxes increases the condensate mass flow rate. (author)

  11. Numerical investigations on unstable direct contact condensation of cryogenic fluids

    Science.gov (United States)

    Jayachandran, K. N.; Arnab, Roy; Parthasarathi, Ghosh

    2017-02-01

    A typical problem of Direct Contact Condensation (DCC) occurs at the liquid oxygen (LOX) booster turbopump exit of oxidiser rich staged combustion cycle based semi-cryogenic rocket engines, where the hot gas mixture (predominantly oxygen and small amounts of combustion products) that runs the turbine mixes with LOX from the pump exit. This complex multiphase phenomena leads to the formation of solid CO2 & H2O, which is undesirable for the functioning of the main LOX turbopump. As a starting point for solving this complex problem, in this study, the hot gas mixture is taken as pure oxygen and hence, DCC of pure oxygen vapour jets in subcooled liquid oxygen is simulated using the commercial CFD package ANSYS CFX®. A two fluid model along with the thermal phase change model is employed for capturing the heat and mass transfer effects. The study mainly focuses on the subsonic DCC bubbling regime, which is reported as unstable with bubble formation, elongation, necking and collapsing effects. The heat transfer coefficients over a period of time have been computed and the various stages of bubbling have been analysed with the help of vapour volume fraction and pressure profiles. The results obtained for DCC of oxygen vapour-liquid mixtures is in qualitative agreement with the experimental results on DCC of steam-water mixtures.

  12. Direct contact with endoderm-like cells efficiently induces cardiac progenitors from mouse and human pluripotent stem cells.

    Directory of Open Access Journals (Sweden)

    Hideki Uosaki

    Full Text Available RATIONALE: Pluripotent stem cell-derived cardiac progenitor cells (CPCs have emerged as a powerful tool to study cardiogenesis in vitro and a potential cell source for cardiac regenerative medicine. However, available methods to induce CPCs are not efficient or require high-cost cytokines with extensive optimization due to cell line variations. OBJECTIVE: Based on our in-vivo observation that early endodermal cells maintain contact with nascent pre-cardiac mesoderm, we hypothesized that direct physical contact with endoderm promotes induction of CPCs from pluripotent cells. METHOD AND RESULT: To test the hypothesis, we cocultured mouse embryonic stem (ES cells with the endodermal cell line End2 by co-aggregation or End2-conditioned medium. Co-aggregation resulted in strong induction of Flk1(+ PDGFRa(+ CPCs in a dose-dependent manner, but the conditioned medium did not, indicating that direct contact is necessary for this process. To determine if direct contact with End2 cells also promotes the induction of committed cardiac progenitors, we utilized several mouse ES and induced pluripotent (iPS cell lines expressing fluorescent proteins under regulation of the CPC lineage markers Nkx2.5 or Isl1. In agreement with earlier data, co-aggregation with End2 cells potently induces both Nkx2.5(+ and Isl1(+ CPCs, leading to a sheet of beating cardiomyocytes. Furthermore, co-aggregation with End2 cells greatly promotes the induction of KDR(+ PDGFRa(+ CPCs from human ES cells. CONCLUSIONS: Our co-aggregation method provides an efficient, simple and cost-effective way to induce CPCs from mouse and human pluripotent cells.

  13. Differences in ground contact time explain the less efficient running economy in north african runners.

    Science.gov (United States)

    Santos-Concejero, J; Granados, C; Irazusta, J; Bidaurrazaga-Letona, I; Zabala-Lili, J; Tam, N; Gil, S M

    2013-09-01

    The purpose of this study was to investigate the relationship between biomechanical variables and running economy in North African and European runners. Eight North African and 13 European male runners of the same athletic level ran 4-minute stages on a treadmill at varying set velocities. During the test, biomechanical variables such as ground contact time, swing time, stride length, stride frequency, stride angle and the different sub-phases of ground contact were recorded using an optical measurement system. Additionally, oxygen uptake was measured to calculate running economy. The European runners were more economical than the North African runners at 19.5 km · h(-1), presented lower ground contact time at 18 km · h(-1) and 19.5 km · h(-1) and experienced later propulsion sub-phase at 10.5 km · h(-1),12 km · h(-1), 15 km · h(-1), 16.5 km · h(-1) and 19.5 km · h(-1) than the European runners (P Running economy at 19.5 km · h(-1) was negatively correlated with swing time (r = -0.53) and stride angle (r = -0.52), whereas it was positively correlated with ground contact time (r = 0.53). Within the constraints of extrapolating these findings, the less efficient running economy in North African runners may imply that their outstanding performance at international athletic events appears not to be linked to running efficiency. Further, the differences in metabolic demand seem to be associated with differing biomechanical characteristics during ground contact, including longer contact times.

  14. State of technology of direct contact heat exchanging

    Energy Technology Data Exchange (ETDEWEB)

    Vallario, R.W.; DeBellis, D.E.

    1984-05-01

    Specific objectives of this study were to assess the state of technology development and to identify and evaluate the constraints to wider use of direct contact heat exchanger (DCHE) technology in the U.S. The scope of this study is relatively broad; it includes many types of generic systems and end-use applications, both current and future. Domestic and foreign experience with DCHE technology are compared, although the primary focus is on domestic experience. Twenty-two distinct applications of DCHE technology were identified in this study and are examined in this report. The general format is to describe each system, explore its potential applications, discuss current and past research activities and identify major implementation barriers. Finally, as a result of discussions with principal users of DCHE systems and with other knowledgeable sources, generic and specific R and D needs to overcome specific implementation barriers have been identified. The following list of DCHE systems/concepts has been classified into four major end-uses; there is also a category for specialized (other) applications.

  15. Experimental and numerical investigations on the direct contact condensation phenomenon in horizontal flow channels and its implications in nuclear safety

    Energy Technology Data Exchange (ETDEWEB)

    Ceuca, Sabin Cristian [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) gGmbH, Garching (Germany); Laurinavicius, Darius [Lithuanian Energy Institute, Kaunas (Lithuania)

    2016-11-15

    The complex direct contact condensation phenomenon is investigated in horizontal flow channels both experimentally and numerically with special emphasis on its implications on safety assessment studies. Under certain conditions direct contact condensation can act as the driving force for the water hammer phenomenon with potentially local devastating results, thus posing a threat to the integrity of the affected NPP components. New experimental results of in-depth analysis of the direct contact condensation phenomena obtained in Kaunas at the Lithuanian Energy Institute will be presented. The German system code ATHLET employing for the calculation of the heat transfer coefficient a mechanistic model accounting for two different eddy length scales, combined with the interfacial area transport equation will be assessed against condensation induced water hammer experimental data from the integral thermal-hydraulic experimental facility PMK-2, located at the KFKI Atomic Energy Research Institute in Budapest Hungary.

  16. Characterization of Time-Dependent Contact Angles for Oleic Acid Mixed Sands with Different Particle Size Fractions

    DEFF Research Database (Denmark)

    Wijewardana, Y. N. S.; Kawamoto, Ken; Komatsu, Toshiko

    2014-01-01

    ) mixed sands representing four different particle size fractions ranging from 0.105 to 0.84 mm. Initial soil-water contact angle (αi), and the time dependence of contact angle were measured by the sessile drop method. Results showed that the αi value for fine and middle sand fractions increased rapidly...... in contact angle (α), well captured the time dependence of α....

  17. Contact Lens Risks

    Science.gov (United States)

    ... There is a risk of eye infection from bacteria in swimming pool water, hot tubs, lakes and the ocean Replace your contact lens storage case every 3 months or as directed by your eye care professional. Other Risks of Contact Lenses Other risks of contact lenses include pink eye ( ...

  18. State of the art and challenges in development of electrical contact materials in the light of the RoHS directive

    Directory of Open Access Journals (Sweden)

    Ćosović V.

    2012-01-01

    Full Text Available The article surveys current state of the art and challenges in the development of the electrical contact materials in the light of the EU Directive on Restriction of Hazardous Substances (RoHS. The focus was placed on widely used silver-cadmium alloys. According to this directive, as of July 1, 2006, use of six hazardous materials, including cadmium, are restricted for applicable electrical and electronic products intended for the EU market. In contrast, traditionally preferred material for production of electrical contacts is Ag-CdO, due to its outstanding functional properties. These conflicting interests result in present state where RoHS directive has not yet been implemented in its original form and has undergone numerous amendments and exceptions regarding the use of cadmium. Main reason for this seems to be the unrealistic time frame imposed by legislation. Although, significant effort has been put into research and development of alternative materials, there are still cases where adequate replacement materials had not been found. Therefore, importance of synchronicity between legislation and technological progress i.e. communication between legislative administration and industry and academia is brought to light as well as some common issues that may arise with an introduction of new replacement materials or product modification. [Projekat Ministarstva nauke Republike SRbije, br. OI 172037 and TR 34023

  19. Time-to-contact estimation modulated by implied friction.

    Science.gov (United States)

    Yamada, Yuki; Sasaki, Kyoshiro; Miura, Kayo

    2014-01-01

    The present study demonstrated that friction cues for target motion affect time-to-contact (TTC) estimation. A circular target moved in a linear path with a constant velocity and was gradually occluded by a static rectangle. The target moved with forward and backward spins or without spin. Observers were asked to respond at the time when the moving target appeared to pass the occluder. The results showed that TTC was significantly longer in the backward spin condition than in the forward and without-spin conditions. Moreover, similar results were obtained when a sound was used to imply friction. Our findings indicate that the observer's experiential knowledge of motion coupled with friction intuitively modulated their TTC estimation.

  20. Gait parameter control timing with dynamic manual contact or visual cues

    Science.gov (United States)

    Shi, Peter; Werner, William

    2016-01-01

    We investigated the timing of gait parameter changes (stride length, peak toe velocity, and double-, single-support, and complete step duration) to control gait speed. Eleven healthy participants adjusted their gait speed on a treadmill to maintain a constant distance between them and a fore-aft oscillating cue (a place on a conveyor belt surface). The experimental design balanced conditions of cue modality (vision: eyes-open; manual contact: eyes-closed while touching the cue); treadmill speed (0.2, 0.4, 0.85, and 1.3 m/s); and cue motion (none, ±10 cm at 0.09, 0.11, and 0.18 Hz). Correlation analyses revealed a number of temporal relationships between gait parameters and cue speed. The results suggest that neural control ranged from feedforward to feedback. Specifically, step length preceded cue velocity during double-support duration suggesting anticipatory control. Peak toe velocity nearly coincided with its most-correlated cue velocity during single-support duration. The toe-off concluding step and double-support durations followed their most-correlated cue velocity, suggesting feedback control. Cue-tracking accuracy and cue velocity correlations with timing parameters were higher with the manual contact cue than visual cue. The cue/gait timing relationships generalized across cue modalities, albeit with greater delays of step-cycle events relative to manual contact cue velocity. We conclude that individual kinematic parameters of gait are controlled to achieve a desired velocity at different specific times during the gait cycle. The overall timing pattern of instantaneous cue velocities associated with different gait parameters is conserved across cues that afford different performance accuracies. This timing pattern may be temporally shifted to optimize control. Different cue/gait parameter latencies in our nonadaptation paradigm provide general-case evidence of the independent control of gait parameters previously demonstrated in gait adaptation paradigms

  1. Gait parameter control timing with dynamic manual contact or visual cues.

    Science.gov (United States)

    Rabin, Ely; Shi, Peter; Werner, William

    2016-06-01

    We investigated the timing of gait parameter changes (stride length, peak toe velocity, and double-, single-support, and complete step duration) to control gait speed. Eleven healthy participants adjusted their gait speed on a treadmill to maintain a constant distance between them and a fore-aft oscillating cue (a place on a conveyor belt surface). The experimental design balanced conditions of cue modality (vision: eyes-open; manual contact: eyes-closed while touching the cue); treadmill speed (0.2, 0.4, 0.85, and 1.3 m/s); and cue motion (none, ±10 cm at 0.09, 0.11, and 0.18 Hz). Correlation analyses revealed a number of temporal relationships between gait parameters and cue speed. The results suggest that neural control ranged from feedforward to feedback. Specifically, step length preceded cue velocity during double-support duration suggesting anticipatory control. Peak toe velocity nearly coincided with its most-correlated cue velocity during single-support duration. The toe-off concluding step and double-support durations followed their most-correlated cue velocity, suggesting feedback control. Cue-tracking accuracy and cue velocity correlations with timing parameters were higher with the manual contact cue than visual cue. The cue/gait timing relationships generalized across cue modalities, albeit with greater delays of step-cycle events relative to manual contact cue velocity. We conclude that individual kinematic parameters of gait are controlled to achieve a desired velocity at different specific times during the gait cycle. The overall timing pattern of instantaneous cue velocities associated with different gait parameters is conserved across cues that afford different performance accuracies. This timing pattern may be temporally shifted to optimize control. Different cue/gait parameter latencies in our nonadaptation paradigm provide general-case evidence of the independent control of gait parameters previously demonstrated in gait adaptation paradigms

  2. Contact and contagion: Probability of transmission given contact varies with demographic state in bighorn sheep.

    Science.gov (United States)

    Manlove, Kezia R; Cassirer, E Frances; Plowright, Raina K; Cross, Paul C; Hudson, Peter J

    2017-07-01

    Understanding both contact and probability of transmission given contact are key to managing wildlife disease. However, wildlife disease research tends to focus on contact heterogeneity, in part because the probability of transmission given contact is notoriously difficult to measure. Here, we present a first step towards empirically investigating the probability of transmission given contact in free-ranging wildlife. We used measured contact networks to test whether bighorn sheep demographic states vary systematically in infectiousness or susceptibility to Mycoplasma ovipneumoniae, an agent responsible for bighorn sheep pneumonia. We built covariates using contact network metrics, demographic information and infection status, and used logistic regression to relate those covariates to lamb survival. The covariate set contained degree, a classic network metric describing node centrality, but also included covariates breaking the network metrics into subsets that differentiated between contacts with yearlings, ewes with lambs, and ewes without lambs, and animals with and without active infections. Yearlings, ewes with lambs, and ewes without lambs showed similar group membership patterns, but direct interactions involving touch occurred at a rate two orders of magnitude higher between lambs and reproductive ewes than between any classes of adults or yearlings, and one order of magnitude higher than direct interactions between multiple lambs. Although yearlings and non-reproductive bighorn ewes regularly carried M. ovipneumoniae, our models suggest that a contact with an infected reproductive ewe had approximately five times the odds of producing a lamb mortality event of an identical contact with an infected dry ewe or yearling. Consequently, management actions targeting infected animals might lead to unnecessary removal of young animals that carry pathogens but rarely transmit. This analysis demonstrates a simple logistic regression approach for testing a priori

  3. Systems-on-chip approach for real-time simulation of wheel-rail contact laws

    Science.gov (United States)

    Mei, T. X.; Zhou, Y. J.

    2013-04-01

    This paper presents the development of a systems-on-chip approach to speed up the simulation of wheel-rail contact laws, which can be used to reduce the requirement for high-performance computers and enable simulation in real time for the use of hardware-in-loop for experimental studies of the latest vehicle dynamic and control technologies. The wheel-rail contact laws are implemented using a field programmable gate array (FPGA) device with a design that substantially outperforms modern general-purpose PC platforms or fixed architecture digital signal processor devices in terms of processing time, configuration flexibility and cost. In order to utilise the FPGA's parallel-processing capability, the operations in the contact laws algorithms are arranged in a parallel manner and multi-contact patches are tackled simultaneously in the design. The interface between the FPGA device and the host PC is achieved by using a high-throughput and low-latency Ethernet link. The development is based on FASTSIM algorithms, although the design can be adapted and expanded for even more computationally demanding tasks.

  4. Method of dimensionality reduction in contact mechanics and friction

    CERN Document Server

    Popov, Valentin L

    2015-01-01

    This book describes for the first time a simulation method for the fast calculation of contact properties and friction between rough surfaces in a complete form. In contrast to existing simulation methods, the method of dimensionality reduction (MDR) is based on the exact mapping of various types of three-dimensional contact problems onto contacts of one-dimensional foundations. Within the confines of MDR, not only are three dimensional systems reduced to one-dimensional, but also the resulting degrees of freedom are independent from another. Therefore, MDR results in an enormous reduction of the development time for the numerical implementation of contact problems as well as the direct computation time and can ultimately assume a similar role in tribology as FEM has in structure mechanics or CFD methods, in hydrodynamics. Furthermore, it substantially simplifies analytical calculation and presents a sort of “pocket book edition” of the entirety contact mechanics. Measurements of the rheology of bodies in...

  5. The effect of non-condensable gas on direct contact condensation of steam/air mixture

    International Nuclear Information System (INIS)

    Lee, H. C.; Park, S. K.; Kim, M. H.

    1998-01-01

    To investigate the effects of noncondensable gas on the direct contact film condensation of vapor mixture, a series of experiments has been carried out. The rectangular duct inclined 87.deg. to the horizontal plane was used for this experiment. The average heat transfer coefficient of the steam-air mixture was obtained at the atmospheric pressure with four main parameters, air-mass fraction, vapor velocity, film Reynolds number,and the degree of water film subcooling having an influence on the condensation heat transfer coefficient. With the analysis on 88 cases of experiments, a correlation of the average Nusselt number for direct contact film condensation of steam-air mixture at a vertical wall proposed as functions of film Reynolds number, mixture Reynolds number, air mass fraction, and Jacob number. The average heat transfer coefficient for steam-air mixture condensation decreased significantly while air mass fraction increases with the same inlet mixture velocity and inlet film temperature. The average heat transfer coefficients also decreased with the degree of film subcooling increasing and were scarcely affected by film Reynolds number below the mixture Reynolds number about 30,000

  6. A mathematical model for the control of carrier-dependent infectious diseases with direct transmission and time delay

    International Nuclear Information System (INIS)

    Misra, A.K.; Mishra, S.N.; Pathak, A.L.; Srivastava, P.K.; Chandra, Peeyush

    2013-01-01

    In this paper, a non-linear delay mathematical model for the control of carrier-dependent infectious diseases through insecticides is proposed and analyzed. In the modeling process, it is assumed that disease spreads due to direct contact between susceptibles and infectives as well as through carriers (indirect contact). Further, it is assumed that insecticides are used to kill carriers and the rate of introduction of insecticides is proportional to the density of carriers with some time lag. The model analysis suggests that as delay in using insecticides exceeds some critical value, the system loses its stability and Hopf-bifurcation occurs. The direction, stability and period of the bifurcating periodic solutions arising through Hopf-bifurcation are also analyzed using normal form concept and center manifold theory. Numerical simulation is carried out to confirm the obtained analytical results

  7. Analysis of contact stiffness in ultrasound atomic force microscopy: three-dimensional time-dependent ultrasound modeling

    International Nuclear Information System (INIS)

    Piras, Daniele; Sadeghian, Hamed

    2017-01-01

    Ultrasound atomic force microscopy (US-AFM) has been used for subsurface imaging of nanostructures. The contact stiffness variations have been suggested as the origin of the image contrast. Therefore, to analyze the image contrast, the local changes in the contact stiffness due to the presence of subsurface features should be calculated. So far, only static simulations have been conducted to analyze the local changes in the contact stiffness and, consequently, the contrast in US-AFM. Such a static approach does not fully represent the real US-AFM experiment, where an ultrasound wave is launched either into the sample or at the tip, which modulates the contact stiffness. This is a time-dependent nonlinear dynamic problem rather than a static and stationary one. This paper presents dynamic 3D ultrasound analysis of contact stiffness in US-AFM (in contrast to static analysis) to realistically predict the changes in contact stiffness and thus the changes in the subsurface image contrast. The modulation frequency also influences the contact stiffness variations and, thus, the image contrast. The three-dimensional time-dependent ultrasound analysis will greatly aid in the contrast optimization of subsurface nano imaging with US-AFM. (paper)

  8. Direct contact between dendritic cells and bronchial epithelial cells inhibits T cell recall responses towards mite and pollen allergen extracts in vitro

    DEFF Research Database (Denmark)

    Papazian, Dick; Wagtmann, Valery R; Hansen, Soren

    2015-01-01

    (DCs), we have investigated recall T cell responses in allergic patients sensitized to house dust mite, grass, and birch pollen. Conclusions: Using allergen extract-loaded DCs to stimulate autologous allergen-specific T cell lines, we show that AEC-imprinted DCs inhibit T cell proliferation...... production of both Th1 and Th2 cytokines upon re-challenge. The inhibitory effects of AECs' contact with DCs were absent when allergen extract-loaded DCs had only been exposed to AECs supernatants, but present after direct contact with AECs. We conclude that direct contact between DCs and AECs inhibits T...

  9. Contact allergy to the 26 specific fragrance ingredients to be declared on cosmetic products in accordance with the EU cosmetics directive

    DEFF Research Database (Denmark)

    Heisterberg, Maria V; Menné, Torkil; Johansen, Jeanne D

    2011-01-01

    Background. Fragrance ingredients are a frequent cause of allergic contact dermatitis. The EU Cosmetics Directive states that 26 specific fragrance ingredients, known to cause allergic contact dermatitis, must be declared on the ingredient lists of cosmetic products. Objectives. To investigate...

  10. Who is the Usual Suspect? Evidence of a Selection Bias Toward Faces That Make Direct Eye Contact in a Lineup Task

    Science.gov (United States)

    van Golde, Celine; Verstraten, Frans A. J.

    2017-01-01

    The speed and ease with which we recognize the faces of our friends and family members belies the difficulty we have recognizing less familiar individuals. Nonetheless, overconfidence in our ability to recognize faces has carried over into various aspects of our legal system; for instance, eyewitness identification serves a critical role in criminal proceedings. For this reason, understanding the perceptual and psychological processes that underlie false identification is of the utmost importance. Gaze direction is a salient social signal and direct eye contact, in particular, is thought to capture attention. Here, we tested the hypothesis that differences in gaze direction may influence difficult decisions in a lineup context. In a series of experiments, we show that when a group of faces differed in their gaze direction, the faces that were making eye contact with the participants were more likely to be misidentified. Interestingly, this bias disappeared when the faces are presented with their eyes closed. These findings open a critical conversation between social neuroscience and forensic psychology, and imply that direct eye contact may (wrongly) increase the perceived familiarity of a face. PMID:28203355

  11. Who is the Usual Suspect? Evidence of a Selection Bias Toward Faces That Make Direct Eye Contact in a Lineup Task

    Directory of Open Access Journals (Sweden)

    Jessica Taubert

    2017-02-01

    Full Text Available The speed and ease with which we recognize the faces of our friends and family members belies the difficulty we have recognizing less familiar individuals. Nonetheless, overconfidence in our ability to recognize faces has carried over into various aspects of our legal system; for instance, eyewitness identification serves a critical role in criminal proceedings. For this reason, understanding the perceptual and psychological processes that underlie false identification is of the utmost importance. Gaze direction is a salient social signal and direct eye contact, in particular, is thought to capture attention. Here, we tested the hypothesis that differences in gaze direction may influence difficult decisions in a lineup context. In a series of experiments, we show that when a group of faces differed in their gaze direction, the faces that were making eye contact with the participants were more likely to be misidentified. Interestingly, this bias disappeared when the faces are presented with their eyes closed. These findings open a critical conversation between social neuroscience and forensic psychology, and imply that direct eye contact may (wrongly increase the perceived familiarity of a face.

  12. Direct observation of contact and channel resistance in pentacene four-terminal thin-film transistor patterned by laser ablation method

    International Nuclear Information System (INIS)

    Yagi, Iwao; Tsukagoshi, Kazuhito; Aoyagi, Yoshinobu

    2004-01-01

    We established a dry-etching patterning process for the channel formation of pentacene thin-film transistor, and fabricated a four-terminal device equipped with a gate electrode. The four-terminal device enabled us to divide two-terminal source-drain resistance into two components of contact resistance and pentacene channel resistance. We obtained direct evidence of a gate-voltagedependent contact resistance change: the gate-induced charge significantly reduced the contact resistance and increased source-drain current. Furthermore, the temperature dependence of the device clearly indicated that the contact resistance was much higher than the channel resistance and was dominated in the two-terminal total resistance of the device below 120 K. An observed activation energy of 80 meV for contact resistance was higher than that of 42 meV for pentacene channel resistance

  13. Direct soil contact values for ecological receptors exposed to weathered petroleum hydrocarbon (PHC) fraction 2.

    Science.gov (United States)

    Angell, Robin A; Kullman, Steve; Shrive, Emma; Stephenson, Gladys L; Tindal, Miles

    2012-11-01

    Ecological tier 1 Canada-wide standards (CWS) for petroleum hydrocarbon (PHC) fraction 2 (F2; >nC10-C16) in soil were derived using ecotoxicological assessment endpoints (effective concentrations [ECs]/lethal concentrations [LCs]/inhibitory concentrations, 25% [IC25s]) with freshly spiked (fresh) fine- and coarse-grained soils. These soil standards might be needlessly conservative when applied to field samples with weathered hydrocarbons. The purpose of the present study was to assess the degradation and toxicity of weathered PHC F2 in a fine-grained soil and to derive direct soil contact values for ecological receptors. Fine-grained reference soils were spiked with distilled F2 and weathered for 183 d. Toxicity tests using plants and invertebrates were conducted with the weathered F2-spiked soils. Endpoint EC/IC25s were calculated and used to derive soil standards for weathered F2 in fine-grained soil protective of ecological receptors exposed via direct soil contact. The values derived for weathered F2 were less restrictive than current ecological tier 1 CWS for F2 in soil. Copyright © 2012 SETAC.

  14. Heat transfer modelling of two-phase bubbles swarm condensing in three - phase direct - contact condenser

    Directory of Open Access Journals (Sweden)

    Mahood Hameed B.

    2016-01-01

    Full Text Available An analytical model for the convective heat transfer coefficient and the two-phase bubble size of a three-phase direct contact heat exchanger was developed. Until the present, there has only been a theoretical model available that deals with a single two-phase bubble and a bubble train condensation in an immiscible liquid. However, to understand the actual heat transfer process within the three-phase direct contact condenser, characteristic models are required. A quasi - steady energy equation in a spherical coordinate system with a potential flow assumption and a cell model configuration has been simplified and solved analytically. The convective heat transfer in terms of Nu number has been derived, and it was found to be a function to Pe number and a system void fraction. In addition, the two-phase bubble size relates to the system void fraction and has been developed by solving a simple energy balance equation and using the derived convective heat transfer coefficient expression. Furthermore, the model correlates well with previous experimental data and theoretical results.

  15. Time-related contact angle measurements with human plasma on biomaterial surfaces

    NARCIS (Netherlands)

    Rakhorst, G; Van der Mei, HC; van Oeveren, W; Spijker, HT; Busscher, HJ

    Axisymmetric drop shape analysis by profile (ADSA-P) was used to assess in time contact angle changes of human plasma drops placed on four different biomaterials. Results were related with conventional blood compatibility measurements: albumin adsorption, fibrinogen adsorption and platelet adhesion.

  16. Longer Contact Times Increase Cross-Contamination of Enterobacter aerogenes from Surfaces to Food.

    Science.gov (United States)

    Miranda, Robyn C; Schaffner, Donald W

    2016-11-01

    Bacterial cross-contamination from surfaces to food can contribute to foodborne disease. The cross-contamination rate of Enterobacter aerogenes on household surfaces was evaluated by using scenarios that differed by surface type, food type, contact time (food types were watermelon, bread, bread with butter, and gummy candy. Surfaces (25 cm 2 ) were spot inoculated with 1 ml of inoculum and allowed to dry for 5 h, yielding an approximate concentration of 10 7 CFU/surface. Foods (with a 16-cm 2 contact area) were dropped onto the surfaces from a height of 12.5 cm and left to rest as appropriate. Posttransfer, surfaces and foods were placed in sterile filter bags and homogenized or massaged, diluted, and plated on tryptic soy agar. The transfer rate was quantified as the log percent transfer from the surface to the food. Contact time, food, and surface type all had highly significant effects (P food, while the least bacteria transferred to gummy candy (∼0.1 to 62%). Transfer of bacteria to bread (∼0.02 to 94%) was similar to transfer of bacteria to bread with butter (∼0.02 to 82%), and these transfer rates under a given set of conditions were more variable than with watermelon and gummy candy. The popular notion of the "five-second rule" is that food dropped on the floor and left there for foods (watermelon, bread, bread with butter, and gummy candy), four different contact times (food and the surface, are of equal or greater importance. Some transfer takes place "instantaneously," at times of <1 s, disproving the five-second rule. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  17. Effect of direct eye contact in PTSD related to interpersonal trauma: an fMRI study of activation of an innate alarm system.

    Science.gov (United States)

    Steuwe, Carolin; Daniels, Judith K; Frewen, Paul A; Densmore, Maria; Pannasch, Sebastian; Beblo, Thomas; Reiss, Jeffrey; Lanius, Ruth A

    2014-01-01

    In healthy individuals, direct eye contact initially leads to activation of a fast subcortical pathway, which then modulates a cortical route eliciting social cognitive processes. The aim of this study was to gain insight into the neurobiological effects of direct eye-to-eye contact using a virtual reality paradigm in individuals with posttraumatic stress disorder (PTSD) related to prolonged childhood abuse. We examined 16 healthy comparison subjects and 16 patients with a primary diagnosis of PTSD using a virtual reality functional magnetic resonance imaging paradigm involving direct vs averted gaze (happy, sad, neutral) as developed by Schrammel et al. in 2009. Irrespective of the displayed emotion, controls exhibited an increased blood oxygenation level-dependent response during direct vs averted gaze within the dorsomedial prefrontal cortex, left temporoparietal junction and right temporal pole. Under the same conditions, individuals with PTSD showed increased activation within the superior colliculus (SC)/periaqueductal gray (PAG) and locus coeruleus. Our findings suggest that healthy controls react to the exposure of direct gaze with an activation of a cortical route that enhances evaluative 'top-down' processes underlying social interactions. In individuals with PTSD, however, direct gaze leads to sustained activation of a subcortical route of eye-contact processing, an innate alarm system involving the SC and the underlying circuits of the PAG.

  18. Are diverse societies less cohesive? Testing contact and mediated contact theories.

    Science.gov (United States)

    McKenna, Sarah; Lee, Eunro; Klik, Kathleen A; Markus, Andrew; Hewstone, Miles; Reynolds, Katherine J

    2018-01-01

    Previous research has demonstrated that there is a negative relationship between ethnic diversity in a local community and social cohesion. Often the way social cohesion is assessed, though, varies across studies and only some aspects of the construct are included (e.g., trust). The current research explores the relationship between diversity and social cohesion across a number of indicators of social cohesion including neighbourhood social capital, safety, belonging, generalized trust, and volunteering. Furthermore, social psychological theories concerning the role of positive contact and its impact on feelings of threat are investigated. Using a sample of 1070 third generation 'majority' Australians and structural equation modelling (SEM), findings suggest ethnic diversity is related to positive intergroup contact, and that contact showed beneficial impacts for some indicators of social cohesion both directly and indirectly through reducing perceived threat. When interethnic contact and perceived threat are included in the model there is no direct negative effect between diversity and social cohesion. The theoretical implications of these findings are outlined including the importance of facilitating opportunities for positive contact in diverse communities.

  19. Feedback control for distributed heat transfer mechanisms in direct-contact membrane distillation system

    KAUST Repository

    Eleiwi, Fadi; N'Doye, Ibrahima; Laleg-Kirati, Taous-Meriem

    2015-01-01

    In this paper, the problem of stabilization and production rate reference tracking for a Direct-Contact Membrane Distillation (DCMD) system is addressed. Sufficient conditions for the asymptotic and exponential stabilization for DCMD system are presented using the Gronwall-Bellman lemma and Linear Matrix Inequalities (LMIs) approaches, respectively. A nonlinear observer is then proposed to estimate the temperature distribution among the DCMD domain. This contributes to propose a reference production rate control design for the DCMD process via observer-based output control approach. Finally, numerical simulations are given to show the effectiveness of the proposed methods.

  20. Feedback control for distributed heat transfer mechanisms in direct-contact membrane distillation system

    KAUST Repository

    Eleiwi, Fadi

    2015-09-21

    In this paper, the problem of stabilization and production rate reference tracking for a Direct-Contact Membrane Distillation (DCMD) system is addressed. Sufficient conditions for the asymptotic and exponential stabilization for DCMD system are presented using the Gronwall-Bellman lemma and Linear Matrix Inequalities (LMIs) approaches, respectively. A nonlinear observer is then proposed to estimate the temperature distribution among the DCMD domain. This contributes to propose a reference production rate control design for the DCMD process via observer-based output control approach. Finally, numerical simulations are given to show the effectiveness of the proposed methods.

  1. The effect of elastic modulus on ablation catheter contact area.

    Science.gov (United States)

    Camp, Jon J; Linte, Cristian A; Rettmann, Maryam E; Sun, Deyu; Packer, Douglas L; Robb, Richard A; Holmes, David R

    2015-02-21

    Cardiac ablation consists of navigating a catheter into the heart and delivering RF energy to electrically isolate tissue regions that generate or propagate arrhythmia. Besides the challenges of accurate and precise targeting of the arrhythmic sites within the beating heart, limited information is currently available to the cardiologist regarding intricate electrode-tissue contact, which directly impacts the quality of produced lesions. Recent advances in ablation catheter design provide intra-procedural estimates of tissue-catheter contact force, but the most direct indicator of lesion quality for any particular energy level and duration is the tissue-catheter contact area, and that is a function of not only force, but catheter pose and material elasticity as well. In this experiment, we have employed real-time ultrasound (US) imaging to determine the complete interaction between the ablation electrode and tissue to accurately estimate contact, which will help to better understand the effect of catheter pose and position relative to the tissue. By simultaneously recording tracked position, force reading and US image of the ablation catheter, the differing material properties of polyvinyl alcohol cryogel [1] phantoms are shown to produce varying amounts of tissue depression and contact area (implying varying lesion quality) for equivalent force readings. We have shown that the elastic modulus significantly affects the surface-contact area between the catheter and tissue at any level of contact force. Thus we provide evidence that a prescribed level of catheter force may not always provide sufficient contact area to produce an effective ablation lesion in the prescribed ablation time.

  2. Attention to eye contact in the West and East: autonomic responses and evaluative ratings.

    Science.gov (United States)

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential

  3. Attention to eye contact in the West and East: autonomic responses and evaluative ratings.

    Directory of Open Access Journals (Sweden)

    Hironori Akechi

    Full Text Available Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect. Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish and East Asian (Japanese cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting, shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.. The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from

  4. Optimized programming algorithm for cylindrical and directional deep brain stimulation electrodes.

    Science.gov (United States)

    Anderson, Daria Nesterovich; Osting, Braxton; Vorwerk, Johannes; Dorval, Alan D; Butson, Christopher R

    2018-04-01

    Deep brain stimulation (DBS) is a growing treatment option for movement and psychiatric disorders. As DBS technology moves toward directional leads with increased numbers of smaller electrode contacts, trial-and-error methods of manual DBS programming are becoming too time-consuming for clinical feasibility. We propose an algorithm to automate DBS programming in near real-time for a wide range of DBS lead designs. Magnetic resonance imaging and diffusion tensor imaging are used to build finite element models that include anisotropic conductivity. The algorithm maximizes activation of target tissue and utilizes the Hessian matrix of the electric potential to approximate activation of neurons in all directions. We demonstrate our algorithm's ability in an example programming case that targets the subthalamic nucleus (STN) for the treatment of Parkinson's disease for three lead designs: the Medtronic 3389 (four cylindrical contacts), the direct STNAcute (two cylindrical contacts, six directional contacts), and the Medtronic-Sapiens lead (40 directional contacts). The optimization algorithm returns patient-specific contact configurations in near real-time-less than 10 s for even the most complex leads. When the lead was placed centrally in the target STN, the directional leads were able to activate over 50% of the region, whereas the Medtronic 3389 could activate only 40%. When the lead was placed 2 mm lateral to the target, the directional leads performed as well as they did in the central position, but the Medtronic 3389 activated only 2.9% of the STN. This DBS programming algorithm can be applied to cylindrical electrodes as well as novel directional leads that are too complex with modern technology to be manually programmed. This algorithm may reduce clinical programming time and encourage the use of directional leads, since they activate a larger volume of the target area than cylindrical electrodes in central and off-target lead placements.

  5. Contact Dermatitis in Pediatrics.

    Science.gov (United States)

    Pelletier, Janice L; Perez, Caroline; Jacob, Sharon E

    2016-08-01

    Contact dermatitis is an umbrella term that describes the skin's reaction to contacted noxious or allergenic substances. The two main categories of contact dermatitis are irritant type and allergic type. This review discusses the signs, symptoms, causes, and complications of contact dermatitis. It addresses the testing, treatment, and prevention of contact dermatitis. Proper management of contact dermatitis includes avoidance measures for susceptible children. Implementation of a nickel directive (regulating the use of nickel in jewelry and other products that come into contact with the skin) could further reduce exposure to the most common allergens in the pediatric population. [Pediatr Ann. 2016;45(8):e287-e292.]. Copyright 2016, SLACK Incorporated.

  6. Surface contact stimulates the just-in-time deployment of bacterial adhesins.

    Science.gov (United States)

    Li, Guanglai; Brown, Pamela J B; Tang, Jay X; Xu, Jing; Quardokus, Ellen M; Fuqua, Clay; Brun, Yves V

    2012-01-01

    The attachment of bacteria to surfaces provides advantages such as increasing nutrient access and resistance to environmental stress. Attachment begins with a reversible phase, often mediated by surface structures such as flagella and pili, followed by a transition to irreversible attachment, typically mediated by polysaccharides. Here we show that the interplay between pili and flagellum rotation stimulates the rapid transition between reversible and polysaccharide-mediated irreversible attachment. We found that reversible attachment of Caulobacter crescentus cells is mediated by motile cells bearing pili and that their contact with a surface results in the rapid pili-dependent arrest of flagellum rotation and concurrent stimulation of polar holdfast adhesive polysaccharide. Similar stimulation of polar adhesin production by surface contact occurs in Asticcacaulis biprosthecum and Agrobacterium tumefaciens. Therefore, single bacterial cells respond to their initial contact with surfaces by triggering just-in-time adhesin production. This mechanism restricts stable attachment to intimate surface interactions, thereby maximizing surface attachment, discouraging non-productive self-adherence, and preventing curing of the adhesive. © 2011 Blackwell Publishing Ltd.

  7. New directions in point-contact spectroscopy based on scanning tunneling microscopy techniques (Review Article)

    International Nuclear Information System (INIS)

    Tartaglini, E.; Verhagen, T.G.A.; Galli, F.; Trouwborst, M.L.; Aarts, J.; Van-Ruitebbeek, J.M.; Muller, R.; Shiota, T.

    2013-01-01

    Igor Yanson showed 38 years ago for the first time a point-contact measurement where he probed the energy resolved spectroscopy of the electronic scattering inside the metal. Since this first measurement, the pointcontact spectroscopy (PCS) technique improved enormously. The application of the scanning probe microscopy (SPM) techniques in the late 1980s allowed achieving contacts with a diameter of a single atom. With the introduction of the mechanically controlled break junction technique, even spectroscopy on freely suspended chains of atoms could be performed. In this paper, we briefly review the current developments of PCS and show recent experiments in advanced scanning PCS based on SPM techniques. We describe some results obtained with both needle-anvil type of point contacts and scanning tunneling microscopy (STM). We also show our first attempt to lift up with a STM a chain of single gold atoms from a Au(110) surface.

  8. Effect of feed flow pattern on the distribution of permeate fluxes in desalination by direct contact membrane distillation

    KAUST Repository

    Soukane, Sofiane; Naceur, Mohamed W.; Francis, Lijo; Alsaadi, Ahmad Salem; Ghaffour, NorEddine

    2017-01-01

    The current study aims to highlight the effect of flow pattern on the variations of permeate fluxes over the membrane surface during desalination in a direct contact membrane distillation (DCMD) flat module. To do so, a three dimensional (3D

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... prescription. Follow the contact lens care directions for cleaning, disinfecting, and wearing the lenses. Never share contact ... with Industry Medical Disclaimer Privacy Policy Terms of Service For Advertisers For Media Ophthalmology Job Center © American ...

  10. Direct measurement of time dependent diffusion for Ag and Au under ambient conditions

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Pil Sun; Jo, Han Yeol; Kim, Tae Kyeong [Hankuk University of Foreign Studies, Yongin (Korea, Republic of)

    2014-12-15

    Time-dependent diffusion for Ag and Au metal atoms was measured using the scanning tunneling microscope break-junction technique in ambient conditions. We observed that Ag contacts do not form long single-atomic chains compared to Au contacts during the elongation of each metal electrode, and Ag atoms diffuse more quickly than Au atoms after metal contact rupture. This is consistent with previous results of molecular dynamic simulations. Further, we found a correlation between diffusion length and the evolution time on an atomic scale to reveal the time-dependent diffusion for Ag and Au metal atoms.

  11. Study of Direct-Contact HfO2/Si Interfaces

    Directory of Open Access Journals (Sweden)

    Noriyuki Miyata

    2012-03-01

    Full Text Available Controlling monolayer Si oxide at the HfO2/Si interface is a challenging issue in scaling the equivalent oxide thickness of HfO2/Si gate stack structures. A concept that the author proposes to control the Si oxide interface by using ultra-high vacuum electron-beam HfO2 deposition is described in this review paper, which enables the so-called direct-contact HfO2/Si structures to be prepared. The electrical characteristics of the HfO2/Si metal-oxide-semiconductor capacitors are reviewed, which suggest a sufficiently low interface state density for the operation of metal-oxide-semiconductor field-effect-transistors (MOSFETs but reveal the formation of an unexpected strong interface dipole. Kelvin probe measurements of the HfO2/Si structures provide obvious evidence for the formation of dipoles at the HfO2/Si interfaces. The author proposes that one-monolayer Si-O bonds at the HfO2/Si interface naturally lead to a large potential difference, mainly due to the large dielectric constant of the HfO2. Dipole scattering is demonstrated to not be a major concern in the channel mobility of MOSFETs.

  12. Influence of contact time and sediment composition on the bioavailability of Cd in sediments

    International Nuclear Information System (INIS)

    Zhong Huan; Kraemer, Lisa; Evans, Douglas

    2013-01-01

    Stable isotope 111 Cd was spiked into sediments of different organic content levels for 3 days to 2 months. Bioavailability of spiked Cd to deposit-feeders, assessed by in vitro Cd solubilization, generally decreased with contact time but became comparable with that of background Cd after 2 months. This could be explained by the gradual transfer of Cd from the more mobile geochemical phase (carbonate associated phase) to more refractory phases (Fe–Mn oxide associated phase, and organic associated phase) within 2 months. The sedimentary organic content had a weak effect on Cd solubilization, while the distribution of Cd in carbonate or Fe–Mn oxide associated phase could have a larger influence on the solubilization of sedimentary Cd and its change with contact time. The observations in this study emphasize the need to consider Cd sequestration over time in sediments of various compositions, which would be useful in risk assessment of contaminated sediments. Highlights: ► Cd may reach equilibrium in sediments after 2 months of aging. ► Sediment composition could affect change of Cd bioavailability with contact time. ► Sedimentary organic content has a weak effect on Cd bioavailability. ► Cd associated with carbonates is more bioavailable than Cd with Fe/Mn oxides. ► Change in Cd solid speciation explains decrease of Cd bioavailability over time. - Transfer of Cd from carbonate phase to Fe–Mn oxide phase in sediments was important in affecting the decrease of Cd bioavailability over time.

  13. From interatomic interaction potentials via Einstein field equation techniques to time dependent contact mechanics

    International Nuclear Information System (INIS)

    Schwarzer, N

    2014-01-01

    In order to understand the principle differences between rheological or simple stress tests like the uniaxial tensile test to contact mechanical tests and the differences between quasistatic contact experiments and oscillatory ones, this study resorts to effective first principles. This study will show how relatively simple models simulating bond interactions in solids using effective potentials like Lennard-Jones and Morse can be used to investigate the effect of time dependent stress-induced softening or stiffening of these solids. The usefulness of the current study is in the possibility of deriving relatively simple dependences of the bulk-modulus B on time, shear and pressure P with time t. In cases where it is possible to describe, or at least partially describe a material by Lennard-Jones potential approaches, the above- mentioned dependences are even completely free of microscopic material parameters. Instead of bond energies and length, only specific integral parameters like Young’s modulus and Poisson’s ratio are required. However, in the case of time dependent (viscose) material behavior the parameters are not constants anymore. They themselves depend on time and the actual stress field, especially the shear field. A body completely consisting of so called standard linear solid interacting particles will then phenomenologically show a completely different and usually much more complicated mechanical behavior. The influence of the time dependent pressure-shear-induced Young’s modulus change is discussed with respect to mechanical contact experiments and their analysis in the case of viscose materials. (papers)

  14. Small-sized and contacting Pt-WC nanostructures on graphene as highly efficient anode catalysts for direct methanol fuel cells.

    Science.gov (United States)

    Wang, Ruihong; Xie, Ying; Shi, Keying; Wang, Jianqiang; Tian, Chungui; Shen, Peikang; Fu, Honggang

    2012-06-11

    The synergistic effect between Pt and WC is beneficial for methanol electro-oxidation, and makes Pt-WC catalyst a promising anode candidate for the direct methanol fuel cell. This paper reports on the design and synthesis of small-sized and contacting Pt-WC nanostructures on graphene that bring the synergistic effect into full play. Firstly, DFT calculations show the existence of a strong covalent interaction between WC and graphene, which suggests great potential for anchoring WC on graphene with formation of small-sized, well-dispersed WC particles. The calculations also reveal that, when Pt attaches to the pre-existing WC/graphene hybrid, Pt particles preferentially grow on WC rather than graphene. Our experiments confirmed that highly disperse WC nanoparticles (ca. 5 nm) can indeed be anchored on graphene. Also, Pt particles 2-3 nm in size are well dispersed on WC/graphene hybrid and preferentially grow on WC grains, forming contacting Pt-WC nanostructures. These results are consistent with the theoretical findings. X-ray absorption fine structure spectroscopy further confirms the intimate contact between Pt and WC, and demonstrates that the presence of WC can facilitate the crystallinity of Pt particles. This new Pt-WC/graphene catalyst exhibits a high catalytic efficiency toward methanol oxidation, with a mass activity 1.98 and 4.52 times those of commercial PtRu/C and Pt/C catalysts, respectively. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Effect of time derivative of contact area on dynamic friction

    OpenAIRE

    Arakawa, Kazuo

    2015-01-01

    This study investigated dynamic friction during oblique impact of a golf ball by evaluating the ball’s angular velocity, contact force, and the contact area between the ball and target. The effect of the contact area on the angular velocities was evaluated, and the results indicated that the contact area plays an important role in dynamic friction. In this study, the dynamic friction force F was given by F= μN+μη.dA/dt, where μ is the coefficient of friction, N is the contact force, dA/dt is ...

  16. A new technique for direct traceability of contact thermometry Co-C eutectic cells to the ITS-90

    Energy Technology Data Exchange (ETDEWEB)

    Failleau, G.; Deuzé, T.; Bourson, F.; Briaudeau, S.; Sadli, M. [Laboratoire Commun de Métrologie LNE-Cnam, 61 rue du Landy 93210 La Plaine Saint Denis (France)

    2013-09-11

    The eutectic Co-C melting point is a promising system to serve as a thermometric fixed-point in the temperature range above 1084.62 °C (copper freezing point). During the last decade, LNE-Cnam has developed and characterized some fixed-point devices, based on eutectic Co-C alloy, for applications to contact and radiation thermometry. Above 962 °C, the ITS-90 is realized by radiation thermometry by the extrapolation from a Ag, Au or Cu fixed point using the Planck law for radiation. So the only way for assigning a temperature in the scale to a Co-C cell (∼1324 °C) is by radiation thermometry. An indirect method is commonly used to assign a temperature to a high-temperature fixed point (HTFP) cell designed for contact thermometry is to fill a pyrometric cell with the same mixture as the contact thermometry cell. In this case, the temperature assigned to the pyrometric cell is attributed to the contact cell. This paper describes a direct method allowing the determination of the melting temperature realized by a 'contact thermometry' Co-C cell by comparison to a 'radiation thermometry' Co-C cell whose melting temperature was assigned in accordance to the scale by extrapolation from the Cu point. In addition, the same Co-C cell is studied with a standard Pt/Pd thermocouple.

  17. New aspects in allergic contact dermatitis

    DEFF Research Database (Denmark)

    Mørtz, Charlotte G; Andersen, Klaus Ejner

    2008-01-01

    PURPOSE OF REVIEW: To give selected new information on contact allergy and allergic contact dermatitis with focus on diagnostic procedures and pitfalls. RECENT FINDINGS: Recent studies dealing with common contact allergens have improved our understanding of the relationship between positive patch...... contact dermatitis. The main culprits include fragrance chemicals, preservatives, and hair dyes. We are all more or less exposed to cosmetics and topical drugs on a daily basis. The labelling requirements given in the Cosmetics Directive is of great help in tracing the causative allergenic ingredients...... tests and the clinical interpretation and consequences for the patient. SUMMARY: Nickel allergy is still the most common contact allergy in Europe in spite of full implementation of the EU Nickel Directive in 2001. Contact allergens in cosmetics and topical drugs are another common cause of allergic...

  18. Contact tracing with a real-time location system: A case study of increasing relative effectiveness in an emergency department.

    Science.gov (United States)

    Hellmich, Thomas R; Clements, Casey M; El-Sherif, Nibras; Pasupathy, Kalyan S; Nestler, David M; Boggust, Andy; Ernste, Vickie K; Marisamy, Gomathi; Koenig, Kyle R; Hallbeck, M Susan

    2017-12-01

    Contact tracing is the systematic method of identifying individuals potentially exposed to infectious diseases. Electronic medical record (EMR) use for contact tracing is time-consuming and may miss exposed individuals. Real-time location systems (RTLSs) may improve contact identification. Therefore, the relative effectiveness of these 2 contact tracing methodologies were evaluated. During a pertussis outbreak in the United States, a retrospective case study was conducted between June 14 and August 31, 2016, to identify the contacts of confirmed pertussis cases, using EMR and RTLS data in the emergency department of a tertiary care medical center. Descriptive statistics and a paired t test (α = 0.05) were performed to compare contacts identified by EMR versus RTLS, as was correlation between pertussis patient length of stay and the number of potential contacts. Nine cases of pertussis presented to the emergency department during the identified time period. RTLS doubled the potential exposure list (P < .01). Length of stay had significant positive correlation with contacts identified by RTLS (ρ = 0.79; P = .01) but not with EMR (ρ = 0.43; P = .25). RTLS doubled the potential pertussis exposures beyond EMR-based contact identification. Thus, RTLS may be a valuable addition to the practice of contact tracing and infectious disease monitoring. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  19. A general design strategy for block copolymer directed self-assembly patterning of integrated circuits contact holes using an alphabet approach.

    Science.gov (United States)

    Yi, He; Bao, Xin-Yu; Tiberio, Richard; Wong, H-S Philip

    2015-02-11

    Directed self-assembly (DSA) is a promising lithography candidate for technology nodes beyond 14 nm. Researchers have shown contact hole patterning for random logic circuits using DSA with small physical templates. This paper introduces an alphabet approach that uses a minimal set of small physical templates to pattern all contacts configurations on integrated circuits. We illustrate, through experiments, a general and scalable template design strategy that links the DSA material properties to the technology node requirements.

  20. Influence of different sanitizers on food contaminant bacteria: effect of exposure temperature, contact time, and product concentration

    Directory of Open Access Journals (Sweden)

    Cezar Augusto Beltrame

    2012-06-01

    Full Text Available The efficiency of four Sanitizers - peracetic acid, chlorhexidine, quaternary ammonium, and organic acids - was tested in this work using different bacteria recognized as a problem to meat industry, Salmonella sp., S. aureus, E. coli and L. monocytogenes. The effects of sanitizer concentration (0.2, 0.5, 0.6, 1.0, 1.1 and 1.4%, at different temperatures (10 and 45 °C and contact time (2, 10, 15, 18 and 25 minutes were evaluated. Tests in an industrial plant were also carried out considering previously obtained results. In a general way, peracetic acid presented higher efficiencies using low concentration (0.2% and contact time (2 minutes at 10 °C. The tests performed in industrial scale showed that peracetic acid presented a good performance in concentration and contact time lower than that suggested by the suppliers. The use of chlorhexidine and quaternary ammonium led to reasonable results at the indicated conditions, and organic acids were ineffective under concentration and contact time higher than those indicated by the suppliers in relation to Staphylococcus aureus. The results, in general, show that the choice for the most adequate sanitizer depends on the microorganism contaminant, the time available for sanitizer application, and also on the process cost.

  1. Extended release of hyaluronic acid from hydrogel contact lenses for dry eye syndrome.

    Science.gov (United States)

    Maulvi, Furqan A; Soni, Tejal G; Shah, Dinesh O

    2015-01-01

    Current dry eye treatment includes delivering comfort enhancing agents to the eye via eye drops, but low residence time of eye drops leads to low bioavailability. Frequent administration leads to incompliance in patients, so there is a great need for medical device such as contact lenses to treat dry eye. Studies in the past have demonstrated the efficacy of hyaluronic acid (HA) in the treatment of dry eyes using eye drops. In this paper, we present two methods to load HA in hydrogel contact lenses, soaking method and direct entrapment. The contact lenses were characterized by studying their optical and physical properties to determine their suitability as extended wear contact lenses. HA-laden hydrogel contact lenses prepared by soaking method showed release up to 48 h with acceptable physical and optical properties. Hydrogel contact lenses prepared by direct entrapment method showed significant sustained release in comparison to soaking method. HA entrapped in hydrogels resulted in reduction in % transmittance, sodium ion permeability and surface contact angle, while increase in % swelling. The impact on each of these properties was proportional to HA loading. The batch with 200-μg HA loading showed all acceptable values (parameters) for contact lens use. Results of cytotoxicity study indicated the safety of hydrogel contact lenses. In vivo pharmacokinetics studies in rabbit tear fluid showed dramatic increase in HA mean residence time and area under the curve with lenses in comparison to eye drop treatment. The study demonstrates the promising potential of delivering HA through contact lenses for the treatment of dry eye syndrome.

  2. Social contact patterns of school-age children in Taiwan: comparison of the term time and holiday periods.

    Science.gov (United States)

    Chen, S-C; You, Z-S

    2015-04-01

    School closure is one of the most common interventions in the early weeks of an influenza pandemic. Few studies have investigated social contact patterns and compared individual student contact characteristics during the school term and holiday periods in Taiwan. Here, we conducted a well-used questionnaire survey in a junior high school (grades 7-8) in June 2013. All 150 diary-based effective questionnaires covering conversation and skin-to-skin contact behaviour were surveyed. Two questionnaires for each participant were designed to investigate the individual-level difference of contact numbers per day during the two periods. The questionnaire response rate was 44%. The average number of contacts during term time (20·0 contacts per day) and holiday periods (12·6 contacts per day) were significantly different (P holiday periods, the number of contacts decreased by 40%. This study is the first research to investigate the contact numbers and contact characteristics for school-age children during the school term and a holiday period in Taiwan. With regard to public health, this study could provide the basic contact information and database for modelling influenza epidemics for minimizing the spread of influenza that depends on personal contacts for transmission.

  3. Nonlinear time-series analysis of current signal in cathodic contact glow discharge electrolysis

    International Nuclear Information System (INIS)

    Allagui, Anis; Abdelkareem, Mohammad Ali; Rojas, Andrea Espinel; Bonny, Talal; Elwakil, Ahmed S.

    2016-01-01

    In the standard two-electrode configuration employed in electrolytic process, when the control dc voltage is brought to a critical value, the system undergoes a transition from conventional electrolysis to contact glow discharge electrolysis (CGDE), which has also been referred to as liquid-submerged micro-plasma, glow discharge plasma electrolysis, electrode effect, electrolytic plasma, etc. The light-emitting process is associated with the development of an irregular and erratic current time-series which has been arbitrarily labelled as “random,” and thus dissuaded further research in this direction. Here, we examine the current time-series signals measured in cathodic CGDE configuration in a concentrated KOH solution at different dc bias voltages greater than the critical voltage. We show that the signals are, in fact, not random according to the NIST SP. 800-22 test suite definition. We also demonstrate that post-processing low-pass filtered sequences requires less time than the native as-measured sequences, suggesting a superposition of low frequency chaotic fluctuations and high frequency behaviors (which may be produced by more than one possible source of entropy). Using an array of nonlinear time-series analyses for dynamical systems, i.e., the computation of largest Lyapunov exponents and correlation dimensions, and re-construction of phase portraits, we found that low-pass filtered datasets undergo a transition from quasi-periodic to chaotic to quasi-hyper-chaotic behavior, and back again to chaos when the voltage controlling-parameter is increased. The high frequency part of the signals is discussed in terms of highly nonlinear turbulent motion developed around the working electrode.

  4. Determinants of the abilities to jump higher and shorten the contact time in a running 1-legged vertical jump in basketball.

    Science.gov (United States)

    Miura, Ken; Yamamoto, Masayoshi; Tamaki, Hiroyuki; Zushi, Koji

    2010-01-01

    This study was conducted to obtain useful information for developing training techniques for the running 1-legged vertical jump in basketball (lay-up shot jump). The ability to perform the lay-up shot jump and various basic jumps was measured by testing 19 male basketball players. The basic jumps consisted of the 1-legged repeated rebound jump, the 2-legged repeated rebound jump, and the countermovement jump. Jumping height, contact time, and jumping index (jumping height/contact time) were measured and calculated using a contact mat/computer system that recorded the contact and air times. The jumping index indicates power. No significant correlation existed between the jumping height and contact time of the lay-up shot jump, the 2 components of the lay-up shot jump index. As a result, jumping height and contact time were found to be mutually independent abilities. The relationships in contact time between the lay-up shot jump to the 1-legged repeated rebound jump and the 2-legged repeated rebound jump were correlated on the same significance levels (p jumping height existed between the 1-legged repeated rebound jump and the lay-up shot jump (p jumping height between the lay-up shot jump and both the 2-legged repeated rebound jump and countermovement jump. The lay-up shot index correlated more strongly to the 1-legged repeated rebound jump index (p jump index (p jump is effective in improving both contact time and jumping height in the lay-up shot jump.

  5. Organic light-emitting diodes with direct contact-printed red, green, blue, and white light-emitting layers

    Science.gov (United States)

    Chen, Sun-Zen; Peng, Shiang-Hau; Ting, Tzu-Yu; Wu, Po-Shien; Lin, Chun-Hao; Chang, Chin-Yeh; Shyue, Jing-Jong; Jou, Jwo-Huei

    2012-10-01

    We demonstrate the feasibility of using direct contact-printing in the fabrication of monochromatic and polychromatic organic light-emitting diodes (OLEDs). Bright devices with red, green, blue, and white contact-printed light-emitting layers with a respective maximum luminance of 29 000, 29 000, 4000, and 18 000 cd/m2 were obtained with sound film integrity by blending a polymeric host into a molecular host. For the red OLED as example, the maximum luminance was decreased from 29 000 to 5000 cd/m2 as only the polymeric host was used, or decreased to 7000 cd/m2 as only the molecular host was used. The markedly improved device performance achieved in the devices with blended hosts may be attributed to the employed polymeric host that contributed a good film-forming character, and the molecular host that contributed a good electroluminescence character.

  6. Contact: Releasing the news

    Science.gov (United States)

    Pinotti, Roberto

    The problem of mass behavior after man's future contacts with other intelligences in the universe is not only a challenge for social scientists and political leaders all over the world, but also a cultural time bomb as well. In fact, since the impact of CETI (Contact with Extraterrestrial Intelligence) on human civilization, with its different cultures, might cause a serious socio-anthropological shock, a common and predetermined worldwide strategy is necessary in releasing the news after the contact, in order to keep possible manifestations of fear, panic and hysteria under control. An analysis of past studies in this field and of parallel historical situations as analogs suggests a definite "authority crisis" in the public as a direct consequence of an unexpected release of the news, involving a devastating "chain reaction" process (from both the psychological and sociological viewpoints) of anomie and maybe the collapse of today's society. The only way to prevent all this is to prepare the world's public opinion concerning contact before releasing the news, and to develop a long-term strategy through the combined efforts of scientists, political leaders, intelligence agencies and the mass media, in order to create the cultural conditions in which a confrontation with ETI won't affect mankind in a traumatic way. Definite roles and tasks in this multi-level model are suggested.

  7. Adaptation of H9N2 AIV in guinea pigs enables efficient transmission by direct contact and inefficient transmission by respiratory droplets

    Science.gov (United States)

    Sang, Xiaoyu; Wang, Airong; Ding, Jie; Kong, Huihui; Gao, Xiaolong; Li, Lin; Chai, Tongjie; Li, Yuanguo; Zhang, Kun; Wang, Chengyu; Wan, Zhonghai; Huang, Geng; Wang, Tiecheng; Feng, Na; Zheng, Xuexing; Wang, Hualei; Zhao, Yongkun; Yang, Songtao; Qian, Jun; Hu, Guixue; Gao, Yuwei; Xia, Xianzhu

    2015-01-01

    H9N2 avian influenza viruses circulate worldwide in poultry and have sporadically infected humans, raising concern whether H9N2 viruses have pandemic potential. Here, we use a guinea pig model to examine whether serial passage results in adaptive viral changes that confer a transmissible phenotype to a wild-type H9N2 virus. After nine serial passages of an H9N2 virus through guinea pigs, productive transmission by direct contact occurred in 2/3 guinea pig pairs. The efficiency of transmission by direct contact increased following the fifteenth passage and occurred in 3/3 guinea pig pairs. In contrast, airborne transmission of the passaged virus was less efficient and occurred in 1/6 guinea pig pairs and 0/6 ferret pairs after the fifteenth passage. Three amino acid substitutions, HA1-Q227P, HA2-D46E, and NP-E434K, were sufficient for contact transmission in guinea pigs (2/3 pairs). The two HA amino acid substitutions enhanced receptor binding to α2,3-linked sialic acid receptors. Additionally, the HA2-D46E substitution increased virus thermostability whereas the NP-E434K mutation enhanced viral RNA polymerase activity in vitro. Our findings suggest that adaptive changes that enhance viral receptor binding, thermostability, and replicative capacity in mammalian cells can collectively enhance the transmissibility of H9N2 AIVs by direct contact in the guinea pig model. PMID:26552719

  8. Direct Laser Interference Patterning: Tailoring of Contact Area for Frictional and Antibacterial Properties

    Directory of Open Access Journals (Sweden)

    Andreas Rosenkranz

    2016-01-01

    Full Text Available Surface functionalization by topographic micro- and nano-structures in order to achieve unique properties, like super-hydrophobicity or ultrahigh light absorption, is a common strategy in nature. In this paper, direct laser interference patterning (DLIP is presented as a promising tool allowing for the generation of such surface patterns on technical surfaces in order to mimic these biological surfaces and effects. Friction optimization and antibacterial effects by DLIP are exemplarily described. Topographic surface patterns on the micro- and nano-scale demonstrated a significant reduction in the coefficient of friction and bacterial adhesion. It was shown that in both cases, the control of the contact area between surfaces or between surface and bacteria is of utmost importance.

  9. A Class of time-fractional hemivariational inequalities with application to frictional contact problem

    Science.gov (United States)

    Zeng, Shengda; Migórski, Stanisław

    2018-03-01

    In this paper a class of elliptic hemivariational inequalities involving the time-fractional order integral operator is investigated. Exploiting the Rothe method and using the surjectivity of multivalued pseudomonotone operators, a result on existence of solution to the problem is established. Then, this abstract result is applied to provide a theorem on the weak solvability of a fractional viscoelastic contact problem. The process is quasistatic and the constitutive relation is modeled with the fractional Kelvin-Voigt law. The friction and contact conditions are described by the Clarke generalized gradient of nonconvex and nonsmooth functionals. The variational formulation of this problem leads to a fractional hemivariational inequality.

  10. Pulsed Current Static Electrical Contact Experiment

    National Research Council Canada - National Science Library

    Jones, Harry N; Neri, Jesse M; Boyer, Craig N; Cooper, Khershed P; Meger, Robert A

    2006-01-01

    .... The voltage developed across the interface is directly related to the contact temperature and pressure, the number of a-spots, the thermophysical and mechanical properties of the contacting materials...

  11. The Time-Dose-Response Relationship for Elicitation of Contact Dermatitis in Isoeugenol Allergic Individuals

    DEFF Research Database (Denmark)

    Andersen, K. E.; Johansen, J. D.; Bruze, M.

    2001-01-01

    The elicitation response in allergic contact dermatitis is dose dependent, but the time-concentration relationship for elicitation has not previously been described. In this study 27 isoeugenol-sensitive patients participated in serial dilution patch tests with isoeugenol and a double-blinded Rep......The elicitation response in allergic contact dermatitis is dose dependent, but the time-concentration relationship for elicitation has not previously been described. In this study 27 isoeugenol-sensitive patients participated in serial dilution patch tests with isoeugenol and a double......-blinded Repeated Open Application Test (ROAT) using two concentrations of isoeugenol, 0.2 and 0.05%. Seven controls without isoeugenol allergy were also included. The participants applied 3.72 +/- 1.57 (mean +/- SD) mg/cm(2) of coded isoeugenol solutions twice a day to a 3 x 3 cm(2) area on the volar aspect...... of the right and left arm, respectively. For each test site the applications continued until a reaction appeared or for a maximum of 28 days. The minimal criteria for a positive reaction regarded as allergic contact dermatitis was persistent erythema at the ROAT test site. All controls were negative and 16...

  12. Mechanical Contact Experiments and Simulations

    DEFF Research Database (Denmark)

    Nielsen, Chris Valentin; Martins, P; Zhang, W.

    2011-01-01

    Mechanical contact is studied under dynamic development by means of a combined numerical and experimental investigation. The experiments are designed to allow dynamical development of non-planar contact areas with significant expansion in all three directions as the load is increased. Different....... The overall investigation serves for testing and validating the numerical implementation of the mechanical contact, which is one of the main contributions to a system intended for 3D simulation of resistance welding. Correct modelling of contact between parts to be welded, as well as contact with electrodes......, is crucial for satisfactory modelling of the resistance welding process. The resistance heating at the contact interfaces depends on both contact area and pressure, and as the contact areas develop dynamically, the presented tests are relevant for assessing the validity and accuracy of the mechanical contact...

  13. Repertoire of free-living protozoa in contact lens solutions.

    Science.gov (United States)

    Bouchoucha, Ibtissem; Aziz, Aurore; Hoffart, Louis; Drancourt, Michel

    2016-10-29

    The repertoire of free-living protozoa in contact lens solutions is poorly known despite the fact that such protozoa may act as direct pathogens and may harbor intra-cellular pathogens. Between 2009 and 2014, the contact lens solutions collected from patients presenting at our Ophthalmology Department for clinically suspected keratitis, were cultured on non-nutrient agar examined by microscope for the presence of free-living protozoa. All protozoa were identified by 18S rRNA gene sequencing. A total of 20 of 233 (8.6 %) contact lens solution specimens collected from 16 patients were cultured. Acanthamoeba amoeba in 16 solutions (80 %) collected from 12 patients and Colpoda steini, Cercozoa sp., Protostelium sp. and a eukaryotic more closely related to Vermamoeba sp., were each isolated in one solution. Cercozoa sp., Colpoda sp., Protostelium sp. and Vermamoeba sp. are reported for the first time as contaminating contact lens solutions. The repertoire of protozoa in contact lens solutions is larger than previously known.

  14. Knee medial and lateral contact forces in a musculoskeletal model with subject-specific contact point trajectories.

    Science.gov (United States)

    Zeighami, A; Aissaoui, R; Dumas, R

    2018-03-01

    Contact point (CP) trajectory is a crucial parameter in estimating medial/lateral tibio-femoral contact forces from the musculoskeletal (MSK) models. The objective of the present study was to develop a method to incorporate the subject-specific CP trajectories into the MSK model. Ten healthy subjects performed 45 s treadmill gait trials. The subject-specific CP trajectories were constructed on the tibia and femur as a function of extension-flexion using low-dose bi-plane X-ray images during a quasi-static squat. At each extension-flexion position, the tibia and femur CPs were superimposed in the three directions on the medial side, and in the anterior-posterior and proximal-distal directions on the lateral side to form the five kinematic constraints of the knee joint. The Lagrange multipliers associated to these constraints directly yielded the medial/lateral contact forces. The results from the personalized CP trajectory model were compared against the linear CP trajectory and sphere-on-plane CP trajectory models which were adapted from the commonly used MSK models. Changing the CP trajectory had a remarkable impact on the knee kinematics and changed the medial and lateral contact forces by 1.03 BW and 0.65 BW respectively, in certain subjects. The direction and magnitude of the medial/lateral contact force were highly variable among the subjects and the medial-lateral shift of the CPs alone could not determine the increase/decrease pattern of the contact forces. The suggested kinematic constraints are adaptable to the CP trajectories derived from a variety of joint models and those experimentally measured from the 3D imaging techniques. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. First contact diagnosis and management of contact lens-related complications.

    Science.gov (United States)

    Fagan, Xavier J; Jhanji, Vishal; Constantinou, Marios; Amirul Islam, F M; Taylor, Hugh R; Vajpayee, Rasik B

    2012-08-01

    To describe the spectrum of contact lens-related problems in cases presenting to a tertiary referral eye hospital. A retrospective case record analysis of 111 eyes of 97 consecutive patients was undertaken over a period of five months at the Royal Victorian Eye and Ear Hospital, Melbourne, Australia. Contact lens-related complications (CLRC) were classified into microbial keratitis, sterile corneal infiltrates, corneal epitheliopathy and contact lens-related red eye (CLARE). Main parameters examined were nature of the first contact, clinical diagnosis, and management pattern. Forty-two percent of the initial presentations were to health care practitioners (HCPs) other than ophthalmologists. Mean duration from the onset of symptoms to presentation was 6.3 ± 10.9 days. Forty-nine percent (n = 54) of patients had an associated risk factor, most commonly overnight use of contact lenses (n = 14, 13 %). Most common diagnosis at presentation was corneal epitheliopathy (68 %) followed by sterile infiltrates (10 %), CLARE (8 %) and microbial keratitis (6 %). No significant differences were found in the pattern of treatment modalities administered by ophthalmologists and other HCPs. HCPs other than ophthalmologists are the first contact for contact lens-related problems in a significant proportion of patients. These HCPs manage the majority of CLRC by direct treatment or immediate referral.

  16. Prioritized Contact Transport Stream

    Science.gov (United States)

    Hunt, Walter Lee, Jr. (Inventor)

    2015-01-01

    A detection process, contact recognition process, classification process, and identification process are applied to raw sensor data to produce an identified contact record set containing one or more identified contact records. A prioritization process is applied to the identified contact record set to assign a contact priority to each contact record in the identified contact record set. Data are removed from the contact records in the identified contact record set based on the contact priorities assigned to those contact records. A first contact stream is produced from the resulting contact records. The first contact stream is streamed in a contact transport stream. The contact transport stream may include and stream additional contact streams. The contact transport stream may be varied dynamically over time based on parameters such as available bandwidth, contact priority, presence/absence of contacts, system state, and configuration parameters.

  17. Frequency shift and hysteresis suppression in contact-mode AFM using contact stiffness modulation

    Directory of Open Access Journals (Sweden)

    Belhaq M.

    2012-07-01

    Full Text Available In this paper the frequency response shift and hysteresis suppression of contact-mode atomic force microscopy is investigated using parametric modulation of the contact stiffness. Based on the Hertzian contact theory, a lumped single degree of freedom oscillator is considered for modeling the cantilever dynamics contact-mode atomic force microscopy. We use the technique of direct partition of motion and the method of multiple scales to obtain, respectively, the slow dynamic and the corresponding slow flow of the system. As results, this study shows that the amplitude of the contact stiffness modulation has a significant effect on the frequency response. Specifically, increasing the amplitude of the stiffness modulation suppresses hysteresis, decreases the peak amplitude and produces shifts towards higher and lower frequencies.

  18. Contact allergy to the 26 specific fragrance ingredients to be declared on cosmetic products in accordance with the EU cosmetics directive

    DEFF Research Database (Denmark)

    Heisterberg, Maria V; Menné, Torkil; Johansen, Jeanne D

    2011-01-01

    Background. Fragrance ingredients are a frequent cause of allergic contact dermatitis. The EU Cosmetics Directive states that 26 specific fragrance ingredients, known to cause allergic contact dermatitis, must be declared on the ingredient lists of cosmetic products. Objectives. To investigate...... frequencies of sensitization to the 26 individual fragrances and evaluate their importance as screening markers of fragrance allergy. Method. This was a retrospective study based on data from the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte. Eczema patients (n = 1508) were patch...

  19. Computational simulations of direct contact condensation as the driving force for water hammer

    International Nuclear Information System (INIS)

    Ceuca, Sabin-Cristian

    2015-01-01

    An analysis, based on Computer Simulations of the Direct Contact Condensation as the Driving Force for the Condensation Induced Water Hammer phenomenon is performed within this thesis. The goal of the work is to develop a mechanistic HTC model, with predictive capabilities for the simulation of horizontal or nearly horizontal two-phase ows with complex patterns including the e ect of interfacial heat and mass transfer. The newly developed HTC model was implemented into the system code ATHLET and into the CFD tools ANSYS CFX and OpenFOAM. Validation calculations have been performed for horizontal or nearly horizontal ows, where simulation results have been compared against the local measurement data such as void and temperature or area averaged data delivered by a wire mesh sensor.

  20. Computational simulations of direct contact condensation as the driving force for water hammer

    Energy Technology Data Exchange (ETDEWEB)

    Ceuca, Sabin-Cristian

    2015-04-27

    An analysis, based on Computer Simulations of the Direct Contact Condensation as the Driving Force for the Condensation Induced Water Hammer phenomenon is performed within this thesis. The goal of the work is to develop a mechanistic HTC model, with predictive capabilities for the simulation of horizontal or nearly horizontal two-phase ows with complex patterns including the e ect of interfacial heat and mass transfer. The newly developed HTC model was implemented into the system code ATHLET and into the CFD tools ANSYS CFX and OpenFOAM. Validation calculations have been performed for horizontal or nearly horizontal ows, where simulation results have been compared against the local measurement data such as void and temperature or area averaged data delivered by a wire mesh sensor.

  1. Ocular surface displacement with and without contact lenses during non-contact tonometry.

    Science.gov (United States)

    Rimayanti, Ulfah; Kiuchi, Yoshiaki; Uemura, Shohei; Takenaka, Joji; Mochizuki, Hideki; Kaneko, Makoto

    2014-01-01

    To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft contact lenses (CLs). One eye each in 21 subjects was studied. The cornea was photographed using a high-speed camera at 5,000 frames/sec during non-contact tonometry without contact lenses (NCL), with -5.0 diopters (D), -0.5 D and +5.0 D CL. The displacement of the ocular surface and the factors affecting displacement at the IOP reading and maximum displacement time were investigated. The IOP readings while wearing +5 D CL were significantly higher than those obtained while wearing -5 D CL. The ocular surface displacement between +5 D CL and other groups were significantly different. A significant positive correlation was found between the ocular surface displacement of subjects at the IOP reading time and the IOP obtained with the non-contact tonometer. A significant negative correlation was found between the ocular surface curvature and the IOP obtained using the non-contact tonometer. The radius of curvature of the ocular surface affected the displacement during the IOP reading and maximum displacement time. Our results indicate that soft contact lens use changes the ocular surface behavior and IOP readings during non-contact tonometry. The radius of curvature of the eye affects the ocular surface displacement and IOP readings in this situation.

  2. A real-time non-contact monitoring method of subsea pipelines

    Directory of Open Access Journals (Sweden)

    Song Dalei

    2015-01-01

    Full Text Available To monitoring the subsea pipeline in real-time, a special potentiometric sensor array and a potential prediction model are presented in this paper. Firstly, to measure the potential of seawater, a special potentiometric sensor array with Ag/AgCl all-solid-state reference electrodes is first developed in this paper. Secondly, according to the obtained distribution law of electric field intensities a prediction model of the pipeline potentials is developed. Finally, the potentiometric sensor array is applied in sink experiment and the prediction model is validated by the sink measurements. The maximum error for pipeline potential prediction model is 1.1 mV. The proposed non-contact monitoring method for subsea pipeline can predict the potential of sea pipeline in real-time, thus providing important information for further subsea pipeline maintenance.

  3. Stability analysis of direct contact heat exchangers subject to system perturbations. Final report, Task 2

    Energy Technology Data Exchange (ETDEWEB)

    Jacobs, H.R.

    1985-01-01

    This report includes a project summary, copies of two papers resulting from the work and the Ph.D. Dissertation of Dr. Mehdi Golafshani entitled, ''Stability of a Direct Contact Heat Exchanger''. Specifically, the work deals with the operational stability of a spray column type heat exchanger subject to disturbances typical of those which can occur for geothermal applications. A computer program was developed to solve the one-dimensional transient two-phase flow problem and it was applied to the design of a spray column. The operation and design of the East Mesa 500kW/sub e/ direct contactor was assessed. It is shown that the heat transfer is governed by the internal resistance of the dispersed phase. In fact, the performance is well-represented by diffusion of heat within the drops. 5 refs.

  4. An effect-directed strategy for characterizing emerging chemicals in food contact materials made from paper and board

    DEFF Research Database (Denmark)

    Rosenmai, Anna Kjerstine; Bengtström, Linda; Taxvig, Camilla

    2017-01-01

    Food contact materials (FCM) are any type of item intended to come into contact with foods and thus represent a potential source for human exposure to chemicals. Regarding FCMs made of paper and board, information pertaining to their chemical constituents and the potential impacts on human health...... FCMs exhibited activities in at least one assay. As proof-of-principle, FCM samples obtained from a sandwich wrapper and a pizza box were carried through a complete step-by-step multi-tiered approach. The pizza box exhibited ER activity, likely caused by the presence of bisphenol A, dibutyl phthalate......, and benzylbutyl phthalate. The sandwich wrapper exhibited AR antagonism, likely caused by abietic acid and dehydroabietic acid. Migration studies confirmed that the active chemicals can transfer from FCMs to food simulants. In conclusion, we report an effect-directed strategy that can identify hazards posed...

  5. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ... wear costume contact lenses for Halloween or any time of year, follow these guidelines: Get an eye ...

  6. Ocular surface displacement with and without contact lenses during non-contact tonometry.

    Directory of Open Access Journals (Sweden)

    Ulfah Rimayanti

    Full Text Available PURPOSE: To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP reading changes caused by wearing soft contact lenses (CLs. METHODS: One eye each in 21 subjects was studied. The cornea was photographed using a high-speed camera at 5,000 frames/sec during non-contact tonometry without contact lenses (NCL, with -5.0 diopters (D, -0.5 D and +5.0 D CL. The displacement of the ocular surface and the factors affecting displacement at the IOP reading and maximum displacement time were investigated. RESULTS: The IOP readings while wearing +5 D CL were significantly higher than those obtained while wearing -5 D CL. The ocular surface displacement between +5 D CL and other groups were significantly different. A significant positive correlation was found between the ocular surface displacement of subjects at the IOP reading time and the IOP obtained with the non-contact tonometer. A significant negative correlation was found between the ocular surface curvature and the IOP obtained using the non-contact tonometer. The radius of curvature of the ocular surface affected the displacement during the IOP reading and maximum displacement time. CONCLUSIONS: Our results indicate that soft contact lens use changes the ocular surface behavior and IOP readings during non-contact tonometry. The radius of curvature of the eye affects the ocular surface displacement and IOP readings in this situation.

  7. Evidence of multiband superconductivity in the quaternary borocarbide superconductor YNi2B2C using directional point-contact spectroscopy

    International Nuclear Information System (INIS)

    Raychaudhuri, Pratap; Sheet, Goutam; Mukhopadhyay, Sourin; Takeya, H.

    2007-01-01

    In this paper, we review our recent investigations on the gap anisotropy of the quaternary borocarbide superconductor YNi 2 B 2 C using directional point-contact spectroscopy. Through a detailed study of the temperature and magnetic field dependence of the superconducting energy gaps we show that the gap anisotropy in this material originates from electrons on different Fermi sheets having very different Fermi velocities. The gap anisotropy in this material is therefore well explained through a multiband scenario where electrons in different k-directions have very different electron-phonon coupling strength

  8. Endoplasmic Reticulum-Plasma Membrane Contact Sites.

    Science.gov (United States)

    Saheki, Yasunori; De Camilli, Pietro

    2017-06-20

    The endoplasmic reticulum (ER) has a broad localization throughout the cell and forms direct physical contacts with all other classes of membranous organelles, including the plasma membrane (PM). A number of protein tethers that mediate these contacts have been identified, and study of these protein tethers has revealed a multiplicity of roles in cell physiology, including regulation of intracellular Ca 2+ dynamics and signaling as well as control of lipid traffic and homeostasis. In this review, we discuss the cross talk between the ER and the PM mediated by direct contacts. We review factors that tether the two membranes, their properties, and their dynamics in response to the functional state of the cell. We focus in particular on the role of ER-PM contacts in nonvesicular lipid transport between the two bilayers mediated by lipid transfer proteins.

  9. [Sport injuries in full contact and semi-contact karate].

    Science.gov (United States)

    Greier, K; Riechelmann, H; Ziemska, J

    2014-03-01

    Karate enjoys great popularity both in professional and recreational sports and can be classified into full, half and low contact styles. The aim of this study was the analysis of sports injuries in Kyokushinkai (full contact) and traditional Karate (semi-contact). In a retrospective study design, 215 active amateur karateka (114 full contact, 101 semi-contact) were interviewed by means of a standardised questionnaire regarding typical sport injuries during the last 36 months. Injuries were categorised into severity grade I (not requiring medical treatment), grade II (single medical treatment), grade III (several outpatient medical treatments) and grade IV (requiring hospitalisation). In total, 217 injuries were reported in detail. 125 injuries (58%) occurred in full contact and 92 (42%) in semi-contact karate. The time related injury rate of full contact karateka was 1.9/1000 h compared to 1.3/1000 h of semi-contact karateka (p injuries were musculoskeletal contusions (33% full contact, 20% semi-contact), followed by articular sprains with 19% and 16%. The lower extremity was affected twice as often in full contact (40%) as in semi-contact (20%) karate. Training injuries were reported by 80% of the full contact and 77% of the semi-contact karateka. Most injuries, both in training and competition, occurred in kumite. 75% of the reported injuries of full contact and 70% of semi-contact karateka were classified as low grade (I or II). The high rate of injuries during training and kumite (sparring) points to specific prevention goals. The emphasis should be put on proprioceptive training and consistent warm-up. In the actual competition the referees play a vital role regarding prevention. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Rate and State Friction Relation for Nanoscale Contacts: Thermally Activated Prandtl-Tomlinson Model with Chemical Aging

    Science.gov (United States)

    Tian, Kaiwen; Goldsby, David L.; Carpick, Robert W.

    2018-05-01

    Rate and state friction (RSF) laws are widely used empirical relationships that describe macroscale to microscale frictional behavior. They entail a linear combination of the direct effect (the increase of friction with sliding velocity due to the reduced influence of thermal excitations) and the evolution effect (the change in friction with changes in contact "state," such as the real contact area or the degree of interfacial chemical bonds). Recent atomic force microscope (AFM) experiments and simulations found that nanoscale single-asperity amorphous silica-silica contacts exhibit logarithmic aging (increasing friction with time) over several decades of contact time, due to the formation of interfacial chemical bonds. Here we establish a physically based RSF relation for such contacts by combining the thermally activated Prandtl-Tomlinson (PTT) model with an evolution effect based on the physics of chemical aging. This thermally activated Prandtl-Tomlinson model with chemical aging (PTTCA), like the PTT model, uses the loading point velocity for describing the direct effect, not the tip velocity (as in conventional RSF laws). Also, in the PTTCA model, the combination of the evolution and direct effects may be nonlinear. We present AFM data consistent with the PTTCA model whereby in aging tests, for a given hold time, static friction increases with the logarithm of the loading point velocity. Kinetic friction also increases with the logarithm of the loading point velocity at sufficiently high velocities, but at a different increasing rate. The discrepancy between the rates of increase of static and kinetic friction with velocity arises from the fact that appreciable aging during static contact changes the energy landscape. Our approach extends the PTT model, originally used for crystalline substrates, to amorphous materials. It also establishes how conventional RSF laws can be modified for nanoscale single-asperity contacts to provide a physically based friction

  11. Development of gas-solid direct contact heat exchanger by use of axial flow cyclone

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Akihiko; Yokomine, Takehiko [Kyushu University (Japan). Interdisciplinary Graduate School of Engineering Sciences; Nagafuchi, Tatsuro [Miura Co. Ltd., Matsuyamashi (Japan)

    2004-10-01

    A heat exchanger between particulate or granular materials and gas is developed. It makes use of a swirling gas flow similar to the usual cyclone separators but the difference from them is that the swirl making gas is issued into the cyclone chamber with downward axial velocity component. After it turns the flow direction near the bottom of the chamber, the low temperature gas receives heat from high temperature particles supplied from above at the chamber's center. Through this configuration, a direct contact and quasi counter-flow heat exchange pattern is realized so that the effective recovery of heat carried by particles is achieved. A model heat exchanger was manufactured via several numerical experiments and its performances of heat exchange as well as particle recovery were examined. Attaching a small particle diffuser below the particle-feeding nozzle brought about a drastic improvement of the heat exchange performance without deteriorating the particle recovery efficiency. The outlet gas temperature much higher than the particle outlet temperature was finally obtained, which is never realized in the parallel flow heat exchanger. (author)

  12. CFD simulation of direct contact condensation with ANSYS CFX using surface renewal theory based heat transfer coefficients

    Energy Technology Data Exchange (ETDEWEB)

    Wanninger, Andreas; Ceuca, Sabin Cristian; Macian-Juan, Rafael [Technische Univ. Muenchen, Garching (Germany). Dept. of Nuclear Engineering

    2013-07-01

    Different approaches for the calculation of Direct Contact Condensation (DCC) using Heat Transfer Coefficients (HTC) based on the Surface Renewal Theory (SRT) are tested using the CFD simulation tool ANSYS CFX. The present work constitutes a preliminary study of the flow patterns and conditions observed using different HTC models. A complex 3D flow pattern will be observed in the CFD simulations as well as a strong coupling between the condensation rate and the two-phase flow dynamics. (orig.)

  13. Polymer-interaction driven diffusionof eyeshadow in soft contact lenses.

    Science.gov (United States)

    Tavazzi, Silvia; Rossi, Alessandra; Picarazzi, Sara; Ascagni, Miriam; Farris, Stefano; Borghesi, Alessandro

    2017-10-01

    Soft contact lenses used for the correction of ametropia are often made of hydrogel and silicone-hydrogel materials. Since they are placed directly on the surface of the eye and they are hydrated by tears, eye cosmetics can compromise the lens performance and, even worse, can be transported from an external environment to the ocular surface through the contact lens. The diffusion of the dye component of a purple eyeshadow in soft contact lenses of different materials is here evaluated. Diffusivity is found to be typically higher in silicone-hydrogels than in hydrogels. In hydrogels, diffusivity is greater in the case of lower oxygen transmissibility. Despite differences between materials, absorbed mass of dye is much larger (10-100 times) than the expected mass by simple hydration and swelling of the contact lens. The most contaminated materials are also resistant to cleaning solutions. The results indicate that, notwithstanding the complexity of contact lens networks, diffusion of dye is found to follow Fick's law and it is driven by polymer-dye interaction, which governs lens hydration and swelling. Copyright © 2017 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  14. Neonatal non-contact respiratory monitoring based on real-time infrared thermography

    Directory of Open Access Journals (Sweden)

    Abbas Abbas K

    2011-10-01

    Full Text Available Abstract Background Monitoring of vital parameters is an important topic in neonatal daily care. Progress in computational intelligence and medical sensors has facilitated the development of smart bedside monitors that can integrate multiple parameters into a single monitoring system. This paper describes non-contact monitoring of neonatal vital signals based on infrared thermography as a new biomedical engineering application. One signal of clinical interest is the spontaneous respiration rate of the neonate. It will be shown that the respiration rate of neonates can be monitored based on analysis of the anterior naris (nostrils temperature profile associated with the inspiration and expiration phases successively. Objective The aim of this study is to develop and investigate a new non-contact respiration monitoring modality for neonatal intensive care unit (NICU using infrared thermography imaging. This development includes subsequent image processing (region of interest (ROI detection and optimization. Moreover, it includes further optimization of this non-contact respiration monitoring to be considered as physiological measurement inside NICU wards. Results Continuous wavelet transformation based on Debauches wavelet function was applied to detect the breathing signal within an image stream. Respiration was successfully monitored based on a 0.3°C to 0.5°C temperature difference between the inspiration and expiration phases. Conclusions Although this method has been applied to adults before, this is the first time it was used in a newborn infant population inside the neonatal intensive care unit (NICU. The promising results suggest to include this technology into advanced NICU monitors.

  15. Contact detection for nanomanipulation in a scanning electron microscope.

    Science.gov (United States)

    Ru, Changhai; To, Steve

    2012-07-01

    Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000× magnification while inducing little end-effector damage. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Electric contact arcing

    International Nuclear Information System (INIS)

    Cuthrell, R.E.

    1976-01-01

    Electrical contacts must function properly in many types of components used in nuclear weapon systems. Design, application, and testing of these components require detailed knowledge of chemical and physical phenomena associated with stockpile storage, stockpile testing, and operation. In the past, investigation of these phenomena has led to significant discoveries on the effects of surface contaminants, friction and wear, and the mechanics of closure on contact performance. A recent investigation of contact arcing phenomena which revealed that, preceding contact closure, arcs may occur at voltages lower than had been previously known is described. This discovery is important, since arcing may damage contacts, and repetitive testing of contacts performed as part of a quality assurance program might produce cumulative damage that would yield misleading life-test data and could prevent proper operation of the contacts at some time in the future. This damage can be avoided by determining the conditions under which arcing occurs, and ensuring that these conditions are avoided in contact testing

  17. An analysis direct-contact condensation in horizontal cocurrent stratified flow of steam and cold water

    International Nuclear Information System (INIS)

    Lee, Suk Ho; Kim, Hho Jung

    1992-01-01

    The physical benchmark problem on the direct-contact condensation under the horizontal cocurrent stratified flow was analyzed using the RELAP5/MOD2 and /MOD3 one-dimensional model. Analysis was performed for the Northwestern experiments, which involved condensing steam/water flow in a rectangular channel. The study showed that the RELAP5 interfacial heat transfer model, under the horizontal stratified flow regime, predicted the condensation rate well though the interfacial heat transfer area was underpredicted. However, some discrepancies in water layer thickness and local heat transfer coefficient with experimental results were found especially when there is a wavy interface, and those were satisfied only within the range. (Author)

  18. Road transport working time directive: self-employed and night time provision

    NARCIS (Netherlands)

    Goudswaard, A.; Kuipsers, B.; Schoenmaker, N.; Houtman, I.L.D.; Jettinghoff, K.; Ruijs, P.A.J.; Savenije, W.M.; Osinga, D.S.C.; Koomen, M.

    2006-01-01

    On 23 March 2005, Directive 2002/15/EC concerning the organization of working time of persons performing mobile road transport activities came into force for mobile workers. Self-employed are temporally excluded from the scope of this Directive. Firstly, this report describes the implementation of

  19. Eye contact facilitates awareness of faces during interocular suppression

    NARCIS (Netherlands)

    Stein, T.; Senju, A.; Peelen, M.V.; Sterzer, P.

    Eye contact captures attention and receives prioritized visual processing. Here we asked whether eye contact might be processed outside conscious awareness. Faces with direct and averted gaze were rendered invisible using interocular suppression. In two experiments we found that faces with direct

  20. Keys to Achieving Target First Medical Contact to Balloon Times and Bypassing Emergency Department More Important Than Distance

    Directory of Open Access Journals (Sweden)

    Saad Ezad

    2018-01-01

    Full Text Available Background. Australian guidelines advocate primary percutaneous coronary intervention (PPCI as the reperfusion strategy of choice for ST elevation myocardial infarction (STEMI in patients in whom it can be performed within 90 minutes of first medical contact; otherwise, fibrinolytic therapy is preferred. In a large health district, the reperfusion strategy is often chosen in the prehospital setting. We sought to identify a distance from a PCI centre, which made it unlikely first medical contact to balloon time (FMCTB of less than 90 minutes could be achieved in the Hunter New England health district and to identify causes of delay in patients who were triaged to a PPCI strategy. Methods and Results. We studied 116 patients presenting via the ambulance service with STEMI from January 2016 to December 2016. In patients who were taken directly to the cardiac catheterisation lab, a maximum distance of 50 km from hospital resulted in 75% of patients receiving PCI within 90 minutes and approximately 95% of patients receiving PCI within 120 minutes. Patients who bypassed the emergency department (ED were significantly more likely to have FMCTB of less than 90 minutes (p<0.001 despite having a longer travel distance (28.5 km versus 17.4 km, p<0.001. Patients transiting via the ED were significantly more likely to present out of hours (60 versus 24.2% p<0.001. Conclusions. Patients who do not bypass the ED have a longer FMCTB across all spectrum of distances from the PCI centre; therefore, bypassing the ED is key to achieving target FMCTB times. Using a cutoff distance of 50 km may reduce human error in estimating travel time to our PCI centre and thereby identifying patients who should receive prehospital thrombolysis.

  1. Modeling leukocyte-leukocyte non-contact interactions in a lymph node.

    Directory of Open Access Journals (Sweden)

    Nicola Gritti

    Full Text Available The interaction among leukocytes is at the basis of the innate and adaptive immune-response and it is largely ascribed to direct cell-cell contacts. However, the exchange of a number of chemical stimuli (chemokines allows also non-contact interaction during the immunological response. We want here to evaluate the extent of the effect of the non-contact interactions on the observed leukocyte-leukocyte kinematics and their interaction duration. To this aim we adopt a simplified mean field description inspired by the Keller-Segel chemotaxis model, of which we report an analytical solution suited for slowly varying sources of chemokines. Since our focus is on the non-contact interactions, leukocyte-leukocyte contact interactions are simulated only by means of a space dependent friction coefficient of the cells. The analytical solution of the Keller-Segel model is then taken as the basis of numerical simulations of interactions between leukocytes and their duration. The mean field interaction force that we derive has a time-space separable form and depends on the chemotaxis sensitivity parameter as well as on the chemokines diffusion coefficient and their degradation rate. All these parameters affect the distribution of the interaction durations. We draw a successful qualitative comparison between simulated data and sets of experimental data for DC-NK cells interaction duration and other kinematic parameters. Remarkably, the predicted percentage of the leukocyte-leukocyte interactions falls in the experimental range and depends (~25% increase upon the chemotactic parameter indicating a non-negligible direct effect of the non-contact interaction on the leukocyte interactions.

  2. Modeling leukocyte-leukocyte non-contact interactions in a lymph node.

    Science.gov (United States)

    Gritti, Nicola; Caccia, Michele; Sironi, Laura; Collini, Maddalena; D'Alfonso, Laura; Granucci, Francesca; Zanoni, Ivan; Chirico, Giuseppe

    2013-01-01

    The interaction among leukocytes is at the basis of the innate and adaptive immune-response and it is largely ascribed to direct cell-cell contacts. However, the exchange of a number of chemical stimuli (chemokines) allows also non-contact interaction during the immunological response. We want here to evaluate the extent of the effect of the non-contact interactions on the observed leukocyte-leukocyte kinematics and their interaction duration. To this aim we adopt a simplified mean field description inspired by the Keller-Segel chemotaxis model, of which we report an analytical solution suited for slowly varying sources of chemokines. Since our focus is on the non-contact interactions, leukocyte-leukocyte contact interactions are simulated only by means of a space dependent friction coefficient of the cells. The analytical solution of the Keller-Segel model is then taken as the basis of numerical simulations of interactions between leukocytes and their duration. The mean field interaction force that we derive has a time-space separable form and depends on the chemotaxis sensitivity parameter as well as on the chemokines diffusion coefficient and their degradation rate. All these parameters affect the distribution of the interaction durations. We draw a successful qualitative comparison between simulated data and sets of experimental data for DC-NK cells interaction duration and other kinematic parameters. Remarkably, the predicted percentage of the leukocyte-leukocyte interactions falls in the experimental range and depends (~25% increase) upon the chemotactic parameter indicating a non-negligible direct effect of the non-contact interaction on the leukocyte interactions.

  3. Improvements To Micro Contact Performance And Reliability

    Science.gov (United States)

    2016-12-22

    layers approximately 0.2mm thick. The extruder is controlled in both the x and y directions by servo motors while the plate height is controlled with a...and contact area as the contacts pressed together and shared more surface area as the contacts elastically or plastically pressed together[164]. Figure...CrossRef 33. M. Braunovic, N. K. Myshkin, and V. V. Konchits, Electrical contacts: funda- mentals, applications and technology. CRC press , 2010, vol

  4. Contact with turf algae alters the coral microbiome: contact versus systemic impacts

    Science.gov (United States)

    Pratte, Zoe A.; Longo, Guilherme O.; Burns, Andrew S.; Hay, Mark E.; Stewart, Frank J.

    2018-03-01

    Coral reefs are degrading to algae-dominated reefs worldwide, with alterations of coral microbiomes commonly co-occurring with reef demise. The severe thermal anomaly during the 2016 El Niño event in the South Pacific killed many corals and stressed others. We examined the microbiome of turf algae and of the coral Porites sp. in contact with turf during this thermal event to investigate algal turf effects on the coral microbiome during a period of environmental stress. The microbial composition of turf did not differ between coral-contacted and non-contacted turfs. However, microbiomes of corals in direct contact with turf were similar to those of the turf microbiome, but differed significantly from coral portions 5 cm from the point of turf/coral contact and from portions of the coral that looked most healthy, regardless of location. Although the majority of significant differences occurred in coral samples at the point of contact, a small subset of microbial taxa was enriched in coral tissues taken 5 cm from turf contact compared to all other sample types, including samples from areas of the coral that appeared most healthy. These results suggest that the coral microbiome is susceptible to colonization by microbes from turf, but not vice versa. Results also suggest that algal contact elicits a subtle shift in the coral microbiome just beyond the contact site. The combination of turf microbiome stability and coral microbiome vulnerability at areas of contact may contribute to the continued decline in coral cover and increase in algal cover associated with coral-algae phase shifts.

  5. Real-Time Multi-Directional Equipment Site

    Data.gov (United States)

    Federal Laboratory Consortium — As part of the George E. Brown, Jr. Network for Earthquake Engineering Simulation (NEES) Program, Lehigh University has established the Real-Time Multi-Directional...

  6. Two gap superconductivity in Ba0.55K0.45Fe2As2 single crystals studied by the directional point-contact Andreev reflection spectroscopy

    International Nuclear Information System (INIS)

    Szabo, P.; Pribulova, Z.; Pristas, G.; Bud'ko, S.L.; Canfield, P.C.; Samuely, P.

    2009-01-01

    First directional point-contact Andreev reflection spectroscopy on the Ba 0.55 K 0.45 Fe 2 As 2 single crystals is presented. The spectra show significant differences when measured in the ab plane in comparison with those measured in the c direction. In the latter case no traces of superconducting energy gap could be found, just a reduced point-contact conductance persisting up to about 100 K and indicating reduced density of states. On the other hand within the ab plane two nodeless superconducting energy gaps Δ S ∼2-5 meV and Δ L ∼9-11 meV are detected.

  7. Measuring contact area in a sliding human finger-pad contact.

    Science.gov (United States)

    Liu, X; Carré, M J; Zhang, Q; Lu, Z; Matcher, S J; Lewis, R

    2018-02-01

    The work outlined in this paper was aimed at achieving further understanding of skin frictional behaviour by investigating the contact area between human finger-pads and flat surfaces. Both the static and the dynamic contact areas (in macro- and micro-scales) were measured using various techniques, including ink printing, optical coherence tomography (OCT) and Digital Image Correlation (DIC). In the studies of the static measurements using ink printing, the experimental results showed that the apparent and the real contact area increased with load following a piecewise linear correlation function for a finger-pad in contact with paper sheets. Comparisons indicated that the OCT method is a reliable and effective method to investigate the real contact area of a finger-pad and allow micro-scale analysis. The apparent contact area (from the DIC measurements) was found to reduce with time in the transition from the static phase to the dynamic phase while the real area of contact (from OCT) increased. The results from this study enable the interaction between finger-pads and contact object surface to be better analysed, and hence improve the understanding of skin friction. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Epidemic spreading in annealed directed networks: susceptible-infected-susceptible model and contact process.

    Science.gov (United States)

    Kwon, Sungchul; Kim, Yup

    2013-01-01

    We investigate epidemic spreading in annealed directed scale-free networks with the in-degree (k) distribution P(in)(k)~k(-γ(in)) and the out-degree (ℓ) distribution, P(out)(ℓ)~ℓ(-γ(out)). The correlation of each node on the networks is controlled by the probability r(0≤r≤1) in two different algorithms, the so-called k and ℓ algorithms. For r=1, the k algorithm gives =, whereas the ℓ algorithm gives =. For r=0, = for both algorithms. As the prototype of epidemic spreading, the susceptible-infected-susceptible model and contact process on the networks are analyzed using the heterogeneous mean-field theory and Monte Carlo simulations. The directedness of links and the correlation of the network are found to play important roles in the spreading, so that critical behaviors of both models are distinct from those on undirected scale-free networks.

  9. Eye Contact Facilitates Awareness of Faces during Interocular Suppression

    Science.gov (United States)

    Stein, Timo; Senju, Atsushi; Peelen, Marius V.; Sterzer, Philipp

    2011-01-01

    Eye contact captures attention and receives prioritized visual processing. Here we asked whether eye contact might be processed outside conscious awareness. Faces with direct and averted gaze were rendered invisible using interocular suppression. In two experiments we found that faces with direct gaze overcame such suppression more rapidly than…

  10. Explosive Evaporating Phenomena of Cryogenic Fluids by Direct Contacting Normal Temperature Fluids

    Directory of Open Access Journals (Sweden)

    T Watanabe

    2016-09-01

    Full Text Available Cryogenic fluids have characteristics such as thermal stratification and flashing by pressure release in storage vessel. The mixture of the extreme low temperature fluid and the normal temperature fluid becomes the cause which causes pressure vessel and piping system crush due to explosive boiling and rapid freezing. In recent years in Japan, the demand of cryogenic fluids like a LH2, LNG is increasing because of the advance of fuel cell device technology, hydrogen of engine, and stream of consciousness for environmental agreement. These fuel liquids are cryogenic fluids. On the other hand, as for fisheries as well, the use of a source of energy that environment load is small has been being a pressing need. And, the need of the ice is high, as before, for keeping freshness of marine products in fisheries. Therefore, we carried out the experiments related to promotion of evaporating cryogenic fluids and generation of ice, in the contact directly of the water and liquid nitrogen. From the results of visualization, phenomena of explosive evaporating and ice forming were observed by using video camera.

  11. Polyoxadiazole hollow fibers for produced water treatment by direct contact membrane distillation

    KAUST Repository

    Xu, Jingli

    2018-01-08

    Treatment of produced water in the petroleum industry has been a challenge worldwide. In this study, we evaluated the use of direct contact membrane distillation (DCMD) for this purpose, removing oil and dissolved elements and supplying clean water from waste. We synthesized fluorinated polyoxadiazole, a highly hydrophobic polymer, to fabricate hollow fiber membranes, which were optimized and tested for simulated produced water and real produced water treatment. The process performance was investigated under different operating parameters, such as feed temperature, feed flow velocity and length of the membrane module for 4 days. The results indicate that by increasing feed temperature and feed flow rate the vapor flux increases. The flux decreased with increasing the length of the module due to the decrease of the driving force along the module. The fouling behavior, which corresponds to flux decline and cleaning efficiency of the membrane, was studied. The performance of the fabricated hollow fiber membranes was demonstrated for the treatment of produced water, complying with the industrial reuse and discharge limits.

  12. Is direct measurement of time possible?

    Science.gov (United States)

    Reynolds, Thomas

    2017-08-01

    Is direct measurement of time possible? The answer to this question may depend upon how one understands time. Is time an essential constituent of physical reality? Or is what scientists are talking about when they use the symbol ‘t’ or the word ‘time’ an human cultural construct, as the Chief of the USA NIST Divisions of Time and Frequency and of Quantum Physics has suggested. Few aspects of physics do not reference activity to time, but many discussions within either view of time seem to use one same, largely traditional, language of time. Briefly considering the question of measurement, including from a formal measure-theoretic point of view, clarifies the situation.

  13. Experimental studies of direct contact heat transfer in a slurry bubble column at high gas temperature of a helium–water–alumina system

    International Nuclear Information System (INIS)

    Abdulrahman, M.W.

    2015-01-01

    In this paper, the direct contact heat transfer is investigated experimentally for a helium gas at 90 °C injected through a slurry of water at 22 °C and alumina solid particles in a slurry bubble column reactor. This work examines the effects of superficial gas velocity, static liquid height, solid particles concentration and solid particle size, on the volumetric heat transfer coefficient and slurry temperature of the slurry bubble column reactor. These effects are formulated in forms of empirical equations. From the experimental work, it is found that the volumetric heat transfer coefficient and the slurry temperature increase by increasing the superficial gas velocity with a higher rate of increase at lower superficial gas velocity. In addition, the volumetric heat transfer coefficient and the slurry temperature decrease by increasing the static liquid height and/or the solid concentration at any given superficial gas velocity. Furthermore, it is found that the rate of decrease of the volumetric heat transfer coefficient with the solid concentration is approximately the same for different superficial gas velocities, and the decrease of the slurry temperature with the solid concentration is negligible. - Highlights: • Direct contact heat transfer is investigated experimentally in a slurry bubble column. • Empirical equation of direct contact heat transfer Nusselt number is formulated. • The volumetric heat transfer coefficient increases with superficial gas velocity. • The volumetric heat transfer coefficient decreases with the static liquid height. • The volumetric heat transfer coefficient decreases with the solid concentration.

  14. Quantized conductance in an atom-sized point contact

    DEFF Research Database (Denmark)

    Olesen, L.; Laegsgaard, E.; Stensgaard, I.

    1994-01-01

    We present direct measurements at room temperature of the conductance of a point contact between a scanning tunneling microscope tip and Ni, Cu, and Pt surfaces. As the contact is stretched the conductance jumps in units of 2e2/h. Atomistic simulations of the stretch of the contact combined...

  15. Contact angle control of sessile drops on a tensioned web

    Science.gov (United States)

    Park, Janghoon; Kim, Dongguk; Lee, Changwoo

    2018-04-01

    In this study, the influence of the change of tension applied to flexible and thin web substrate on the contact angle of sessile drop in roll-to-roll system was investigated. Graphene oxide and deionized water solutions were used in the experiments. Tension was changed to 29, 49, and 69 N, and the casting distance of the micropipette and the material was set to 10, 20, and 40 mm, and the droplet volume was set to 10, 20, and 30 μL, respectively. Statistical analysis of three variables and analysis of the variance methodology showed that the casting distance was most significant for the contact angle change, and the most interesting tension variable was also affected. The change in tension caused the maximum contact angle to change by 5.5°. The tension was not uniform in the width direction. When the droplet was applied in the same direction in the width direction, it was confirmed that the tension unevenness had great influence on the contact angle up to 11°. Finally, the casting distance, which has a large effect on the contact angle, was calibrated in the width direction to reduce the width direction contact angle deviation to 1%. This study can be applied to fine patterning research using continuous inkjet printing and aerosol jet printing, which are roll-to-roll processes based on droplet handling.

  16. Importance of the Direct Contact of Amorphous Solid Particles with the Surface of Monolayers for the Transepithelial Permeation of Curcumin.

    Science.gov (United States)

    Kimura, Shunsuke; Kasatani, Sachiha; Tanaka, Megumi; Araki, Kaeko; Enomura, Masakazu; Moriyama, Kei; Inoue, Daisuke; Furubayashi, Tomoyuki; Tanaka, Akiko; Kusamori, Kosuke; Katsumi, Hidemasa; Sakane, Toshiyasu; Yamamoto, Akira

    2016-02-01

    The amorphization has been generally known to improve the absorption and permeation of poorly water-soluble drugs through the enhancement of the solubility. The present study focused on the direct contact of amorphous solid particles with the surface of the membrane using curcumin as a model for water-insoluble drugs. Amorphous nanoparticles of curcumin (ANC) were prepared with antisolvent crystallization method using a microreactor. The solubility of curcumin from ANC was two orders of magnitude higher than that of crystalline curcumin (CC). However, the permeation of curcumin from the saturated solution of ANC was negligible. The transepithelial permeation of curcumin from ANC suspension was significantly increased as compared to CC suspension, while the permeation was unlikely correlated with the solubility, and the increase in the permeation was dependent on the total concentration of curcumin in ANC suspension. The absorptive transport of curcumin (from apical to basal, A to B) from ANC suspension was much higher than the secretory transport (from basal to apical, B to A). In vitro transport of curcumin through air-interface monolayers is large from ANC but negligible from CC particles. These findings suggest that the direct contact of ANC with the absorptive membrane can play an important role in the transport of curcumin from ANC suspension. The results of the study suggest that amorphous particles may be directly involved in the transepithlial permeation of curcumin.

  17. Contact and non-contact ultrasonic measurement in the food industry: a review

    International Nuclear Information System (INIS)

    Mohd Khairi, Mohd Taufiq; Ibrahim, Sallehuddin; Md Yunus, Mohd Amri; Faramarzi, Mahdi

    2016-01-01

    The monitoring of the food manufacturing process is vital since it determines the safety and quality level of foods which directly affect the consumers’ health. Companies which produce high quality products will gain trust from consumers. This factor helps the companies to make profits. The use of efficient and appropriate sensors for the monitoring process can also reduce cost. The food assessing process based on an ultrasonic sensor has attracted the attention of the food industry due to its excellent capabilities in several applications. The utilization of low or high frequencies for the ultrasonic transducer has provided an enormous benefit for analysing, modifying and guaranteeing the quality of food. The contact and non-contact ultrasonic modes for measurement also contributed significantly to the food processing. This paper presents a review of the application of the contact and non-contact mode of ultrasonic measurement focusing on safety and quality control areas. The results from previous researches are shown and elaborated. (topical review)

  18. Contact and non-contact ultrasonic measurement in the food industry: a review

    Science.gov (United States)

    Taufiq Mohd Khairi, Mohd; Ibrahim, Sallehuddin; Yunus, Mohd Amri Md; Faramarzi, Mahdi

    2016-01-01

    The monitoring of the food manufacturing process is vital since it determines the safety and quality level of foods which directly affect the consumers’ health. Companies which produce high quality products will gain trust from consumers. This factor helps the companies to make profits. The use of efficient and appropriate sensors for the monitoring process can also reduce cost. The food assessing process based on an ultrasonic sensor has attracted the attention of the food industry due to its excellent capabilities in several applications. The utilization of low or high frequencies for the ultrasonic transducer has provided an enormous benefit for analysing, modifying and guaranteeing the quality of food. The contact and non-contact ultrasonic modes for measurement also contributed significantly to the food processing. This paper presents a review of the application of the contact and non-contact mode of ultrasonic measurement focusing on safety and quality control areas. The results from previous researches are shown and elaborated.

  19. A close-form solution to predict the total melting time of an ablating slab in contact with a plasma

    International Nuclear Information System (INIS)

    Yeh, F.-B.

    2007-01-01

    An exact melt-through time is derived for a one-dimensional heated slab in contact with a plasma when the melted material is immediately removed. The plasma is composed of a collisionless presheath and sheath on a slab, which partially reflects and secondarily emits ions and electrons. The energy transport from plasma to the surface accounting for the presheath and sheath is determined from the kinetic analysis. This work proposes a semi-analytical model to calculate the total melting time of a slab based on a direct integration of the unsteady heat conduction equation, and provides quantitative results applicable to control the total melting time of the slab. The total melting time as a function of plasma parameters and thermophysical properties of the slab are obtained. The predicted energy transmission factor as a function of dimensionless wall potential agrees well with the experimental data. The effects of reflectivities of the ions and electrons on the wall, electron-to-ion source temperature ratio at the presheath edge, charge number, ion-to-electron mass ratio, ionization energy, plasma flow work-to-heat conduction ratios, Stefan number, melting temperature, Biot number and bias voltage on the total melting time of the slab are quantitatively provided in this work

  20. Mathematical Modeling of Contact Problems of Elasticity Theory with Unilateral Discrete Contact

    Directory of Open Access Journals (Sweden)

    I. V. Stankevich

    2015-01-01

    Full Text Available Development and operation of modern machinery and latest technology require reliable estimates of the strength characteristics of the critical elements of structures and technological equipment under the impact of high-intensity thermomechanical loading, accompanied, as a rule, by complex contact interaction. Mathematical modeling of stress-strain state of such parts and components in the contact area, based on adequate mathematical models, modern numerical methods and efficient algorithms that implement the direct determination of displacement fields, strains and stresses, is the main tool that allows fast acquisition of data required for the calculations of strength and durability. The paper considers an algorithm for constructing the numerical solution of the contact problem of elasticity theory in relation to the body, which has an obvious one-sided discrete contact interaction with an elastic half-space. The proposed algorithm is specially designed to have a correction of the tangential forces at discrete contact points, allowing us to achieve sufficiently accurate implementation of the adopted law of friction. The algorithm is embedded in a general finite element technology, with which the application code is generated. Numerical study of discrete unilateral contact interaction of an elastic plate and a rigid half-space showed a high efficiency of the developed algorithm and the application code that implements it.

  1. Contact mechanics: contact area and interfacial separation from small contact to full contact

    International Nuclear Information System (INIS)

    Yang, C; Persson, B N J

    2008-01-01

    We present a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. The numerical calculations mainly focus on the contact area and the interfacial separation from small contact (low load) to full contact (high load). For a small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For a high load the contact area approaches the nominal contact area (i.e. complete contact), and the interfacial separation approaches zero. The numerical results have been compared with analytical theory and experimental results. They are in good agreement with each other. The present findings may be very important for soft solids, e.g. rubber, or for very smooth surfaces, where complete contact can be reached at moderately high loads without plastic deformation of the solids

  2. Ageing without detailed balance in the bosonic contact and pair-contact processes: exact results

    International Nuclear Information System (INIS)

    Baumann, Florian; Henkel, Malte; Pleimling, Michel; Richert, Jean

    2005-01-01

    Ageing in systems without detailed balance is studied in the exactly solvable bosonic contact process and the critical bosonic pair-contact process. The two-time correlation function and the two-time response function are explicitly found. In the ageing regime, the dynamical scaling of these is analysed and exact results for the ageing exponents and the scaling functions are derived. For the critical bosonic pair-contact process, the autocorrelation and autoresponse exponents agree but the ageing exponents a and b are shown to be distinct

  3. CDEX-1 1 kg point-contact germanium detector for low mass dark matter searches

    International Nuclear Information System (INIS)

    Kang Kejun; Yue Qian; Wu Yucheng

    2013-01-01

    The CDEX collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold point-contact p-type germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact P + electrode and the outside N + electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both P + and N + electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments. (authors)

  4. Effect of pool turbulence on direct contact condensation at a steam/water interface

    International Nuclear Information System (INIS)

    Jackson, J.D.; Zhao, C.L.; Doerffer, S.; Byrne, J.E.; Falaki, H.

    2000-01-01

    Measurements of direct contact condensation beat transfer have been made for the case where the process takes place at the horizontal interface between saturated steam and a pool of water in a vertical cylindrical test section. A submerged vertical jet of subcooled water was injected upwards on the axis to promote the condensation and water was withdrawn at the same rate from the bottom of the pool. In conjunction with the above study, measurements of the turbulent velocity fluctuations just below a free surface produced by the injection of a vertical submerged jet have been measured using hot film anemometry on an isothermal air-water test facility of similar geometry for similar flow conditions at ambient temperature. A correlation is proposed in terms of a Stanton number based on turbulent velocity fluctuation near the interface on the liquid-side. Our results are in good agreement with those of others for similar configurations when compared in terms of condensation Stanton number. (author)

  5. Evaluation of a direct contact heat exchanger; Evaluacion de un intercambiador de calor de contacto directo

    Energy Technology Data Exchange (ETDEWEB)

    Siqueiros, J.; Bonilla, O. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1997-12-31

    In this paper the application areas of the direct contact heat exchangers is discussed, as well as its main characteristics. A description is made of the experimental equipment designed and built at pilot scale including the instrumentation employed. The methodology employed as well as the analysis and the discussion of the results are also presented. [Espanol] Se mencionan las areas de aplicacion de los intercambiadores de calor de contacto directo, asi como sus caracteristicas principales. Se describe el equipo experimental a nivel piloto disenado y construido incluyendo la instrumentacion utilizada. Se presenta la metodologia empleada asi como el analisis y discusion de los resultados.

  6. Evaluation of a direct contact heat exchanger; Evaluacion de un intercambiador de calor de contacto directo

    Energy Technology Data Exchange (ETDEWEB)

    Siqueiros, J; Bonilla, O [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1998-12-31

    In this paper the application areas of the direct contact heat exchangers is discussed, as well as its main characteristics. A description is made of the experimental equipment designed and built at pilot scale including the instrumentation employed. The methodology employed as well as the analysis and the discussion of the results are also presented. [Espanol] Se mencionan las areas de aplicacion de los intercambiadores de calor de contacto directo, asi como sus caracteristicas principales. Se describe el equipo experimental a nivel piloto disenado y construido incluyendo la instrumentacion utilizada. Se presenta la metodologia empleada asi como el analisis y discusion de los resultados.

  7. Comparing contact and immersion freezing from continuous flow diffusion chambers

    Directory of Open Access Journals (Sweden)

    B. Nagare

    2016-07-01

    Full Text Available Ice nucleating particles (INPs in the atmosphere are responsible for glaciating cloud droplets between 237 and 273 K. Different mechanisms of heterogeneous ice nucleation can compete under mixed-phase cloud conditions. Contact freezing is considered relevant because higher ice nucleation temperatures than for immersion freezing for the same INPs were observed. It has limitations because its efficiency depends on the number of collisions between cloud droplets and INPs. To date, direct comparisons of contact and immersion freezing with the same INP, for similar residence times and concentrations, are lacking. This study compares immersion and contact freezing efficiencies of three different INPs. The contact freezing data were obtained with the ETH CoLlision Ice Nucleation CHamber (CLINCH using 80 µm diameter droplets, which can interact with INPs for residence times of 2 and 4 s in the chamber. The contact freezing efficiency was calculated by estimating the number of collisions between droplets and particles. Theoretical formulations of collision efficiencies gave too high freezing efficiencies for all investigated INPs, namely AgI particles with 200 nm electrical mobility diameter, 400 and 800 nm diameter Arizona Test Dust (ATD and kaolinite particles. Comparison of freezing efficiencies by contact and immersion freezing is therefore limited by the accuracy of collision efficiencies. The concentration of particles was 1000 cm−3 for ATD and kaolinite and 500, 1000, 2000 and 5000 cm−3 for AgI. For concentrations  <  5000 cm−3, the droplets collect only one particle on average during their time in the chamber. For ATD and kaolinite particles, contact freezing efficiencies at 2 s residence time were smaller than at 4 s, which is in disagreement with a collisional contact freezing process but in accordance with immersion freezing or adhesion freezing. With “adhesion freezing”, we refer to a contact nucleation

  8. Contact dermatitis in cement workers in Isfahan

    Directory of Open Access Journals (Sweden)

    Iraji Fariba

    2006-01-01

    Full Text Available BACKGROUND: Due to recent industrialization and inadequately protected workers or in other words poor supervision on constructive workers habits in our large city of Isfahan cement contact dermatitis is relatively high especially among cement factory workers and constructive personnel. PURPOSES: To investigate the prevalence rate of cement contact dermatitis in cement factory workers in Isfahan. METHODS: A case-control clinical study was carried out by randomly selecing 150 factory workders and 150 official clerks in a cement factory in Isfahan in 2001. After a complete physical examination, data was recorded in observational checklists. FINDINGS: The percentages of contact dermatitis prevalences in the first and the second groups were 22% and 5.3% respectively. About 60% of cement workers with contact dermatitis were between 30-40 years of age. There was a direct relationship with age in both groups of the workers. In the high-exposure group, the hand eczema along was 70% but in the other group the percentage of involvement was the same in exposed and unexposed anatomical areas. CONCLUSIONS: There was a direct relationship between occurrence and the severity of involvement and duration of contact in the first group. Cent percent of cement workers had contact dermatitis after 10 or less years, but the percentage among the other group was 35%. LIMITATION: Irritant contact dermatitis to cement has not been detected.

  9. Friendly-Sharing: Improving the Performance of City Sensoring through Contact-Based Messaging Applications

    Directory of Open Access Journals (Sweden)

    Jorge Herrera-Tapia

    2016-09-01

    Full Text Available Regular citizens equipped with smart devices are being increasingly used as “sensors” by Smart Cities applications. Using contacts among users, data in the form of messages is obtained and shared. Contact-based messaging applications are based on establishing a short-range communication directly between mobile devices, and on storing the messages in these devices for subsequent delivery to cloud-based services. An effective way to increase the number of messages that can be shared is to increase the contact duration. We thus introduce the Friendly-Sharing diffusion approach, where, during a contact, the users are aware of the time needed to interchange the messages stored in their buffers, and they can thus decide to wait more time in order to increase the message sharing probability. The performance of this approach is anyway closely related to the size of the buffer in the device. We therefore compare various policies either for the message selection at forwarding times and for message dropping when the buffer is full. We evaluate our proposal with a modified version of the Opportunistic Networking Environment (ONE simulator and using real human mobility traces.

  10. Friendly-Sharing: Improving the Performance of City Sensoring through Contact-Based Messaging Applications.

    Science.gov (United States)

    Herrera-Tapia, Jorge; Hernández-Orallo, Enrique; Tomás, Andrés; Manzoni, Pietro; Tavares Calafate, Carlos; Cano, Juan-Carlos

    2016-09-18

    Regular citizens equipped with smart devices are being increasingly used as "sensors" by Smart Cities applications. Using contacts among users, data in the form of messages is obtained and shared. Contact-based messaging applications are based on establishing a short-range communication directly between mobile devices, and on storing the messages in these devices for subsequent delivery to cloud-based services. An effective way to increase the number of messages that can be shared is to increase the contact duration. We thus introduce the Friendly-Sharing diffusion approach, where, during a contact, the users are aware of the time needed to interchange the messages stored in their buffers, and they can thus decide to wait more time in order to increase the message sharing probability. The performance of this approach is anyway closely related to the size of the buffer in the device. We therefore compare various policies either for the message selection at forwarding times and for message dropping when the buffer is full. We evaluate our proposal with a modified version of the Opportunistic Networking Environment (ONE) simulator and using real human mobility traces.

  11. Contact problem for a solid indenter and a viscoelastic half-space described by the spectrum of relaxation and retardation times

    Science.gov (United States)

    Stepanov, F. I.

    2018-04-01

    The mechanical properties of a material which is modeled by an exponential creep kernel characterized by a spectrum of relaxation and retardation times are studied. The research is carried out considering a contact problem for a solid indenter sliding over a viscoelastic half-space. The contact pressure, indentation depth of the indenter, and the deformation component of the friction coefficient are analyzed with respect to the case of half-space material modeled by single relaxation and retardation times.

  12. Irritant Contact Dermatitis : Diagnosis and Risk Factors

    NARCIS (Netherlands)

    Schuttelaar, Maria; Johansen, Jeanne Duus; Lepoittevin, Jean-Pierre; Thyssen, Jacob P.

    2016-01-01

    Irritant contact dermatitis is frequent and is induced by direct and repeated contact with skin irritants such as detergents, abrasives, solvents and physical factors such as dry air and occlusion (by wearing gloves) but also water. When dermatitis has developed, even a minimal skin irritation, like

  13. Influence of Asymmetric Contact Form on Contact Resistance and Schottky Barrier, and Corresponding Applications of Diode.

    Science.gov (United States)

    Zhao, Yudan; Xiao, Xiaoyang; Huo, Yujia; Wang, Yingcheng; Zhang, Tianfu; Jiang, Kaili; Wang, Jiaping; Fan, Shoushan; Li, Qunqing

    2017-06-07

    We have fabricated carbon nanotube and MoS 2 field-effect transistors with asymmetric contact forms of source-drain electrodes, from which we found the current directionality of the devices and different contact resistances under the two current directions. By designing various structures, we can conclude that the asymmetric electrical performance was caused by the difference in the effective Schottky barrier height (Φ SB ) caused by the different contact forms. A detailed temperature-dependent study was used to extract and compare the Φ SB for both contact forms of CNT and MoS 2 devices; we found that the Φ SB for the metal-on-semiconductor form was much lower than that of the semiconductor-on-metal form and is suitable for all p-type, n-type, or ambipolar semiconductors. This conclusion is meaningful with respect to the design and application of nanomaterial electronic devices. Additionally, using the difference in barrier height caused by the contact forms, we have also proposed and fabricated Schottky barrier diodes with a current ratio up to 10 4 ; rectifying circuits consisting of these diodes were able to work in a wide frequency range. This design avoided the use of complex chemical doping or heterojunction methods to achieve fundamental diodes that are relatively simple and use only a single material; these may be suitable for future application in nanoelectronic radio frequency or integrated circuits.

  14. Contact detection for nanomanipulation in a scanning electron microscope

    International Nuclear Information System (INIS)

    Ru, Changhai; To, Steve

    2012-01-01

    Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000× magnification while inducing little end-effector damage. -- Highlights: ► We presents a simple method for obtaining the depth information in SEM-based nanomanipulation. ► Detecting contact between an end-effector and a target surface using SEM as a vision sensor. ► Additional touch/force sensors or specialized hardware need not be added. ► Achieved high repeatability and accuracy. ► Complete automatic contact detection within typically 60 s.

  15. Numerical Investigation on the Performance of an Automotive Thermoelectric Generator with Exhaust-Module-Coolant Direct Contact

    Science.gov (United States)

    Wang, Yiping; Tang, Yulin; Deng, Yadong; Su, Chuqi

    2018-06-01

    Energy conservation and environmental protection have typically been a concern of research. Researchers have confirmed that in automotive engines, just 12-25% of the fuel energy converts into effective work and 30-40% gets wasted in the form of exhaust. Saidur et al. (Energy Policy 37:3650, 2009) and Hasanuzzaman et al. (Energy 36:233, 2011). It will be significant to enhance fuel availability and decrease environmental pollution if the waste heat in the exhaust could be recovered. Thermoelectric generators (TEGs), which can translate heat into electricity, have become a topic of interest for vehicle exhaust waste heat recovery. In conventional automotive TEGs, the thermoelectric modules (TEMs) are arranged between the exhaust tank and the coolant tank. The TEMs do not contact the hot exhaust and coolant, which leads to low heat transfer efficiency. Moreover, to provide enough packing force to keep good contact with the exhaust tank and the coolant tank, the framework required is so robust that the TEGs become too heavy. Therefore, in current study, an automotive TEG was designed which included one exhaust channel, one coolant channel and several TEMs. In the TEG, the TEMs which contacted the exhaust and coolant directly were inserted into the walls of each coolant channel. To evaluate the performance of the automotive TEG, the flow field and temperature field were computed by computational fluid dynamics (CFD). Based on the temperature distribution obtained by CFD and the performance parameters of the modules, the total power generation was obtained by some proved empirical formulas. Compared with conventional automotive TEGs, the power generation per unit volume exhaust was boosted.

  16. Numerical Investigation on the Performance of an Automotive Thermoelectric Generator with Exhaust-Module-Coolant Direct Contact

    Science.gov (United States)

    Wang, Yiping; Tang, Yulin; Deng, Yadong; Su, Chuqi

    2017-12-01

    Energy conservation and environmental protection have typically been a concern of research. Researchers have confirmed that in automotive engines, just 12-25% of the fuel energy converts into effective work and 30-40% gets wasted in the form of exhaust. Saidur et al. (Energy Policy 37:3650, 2009) and Hasanuzzaman et al. (Energy 36:233, 2011). It will be significant to enhance fuel availability and decrease environmental pollution if the waste heat in the exhaust could be recovered. Thermoelectric generators (TEGs), which can translate heat into electricity, have become a topic of interest for vehicle exhaust waste heat recovery. In conventional automotive TEGs, the thermoelectric modules (TEMs) are arranged between the exhaust tank and the coolant tank. The TEMs do not contact the hot exhaust and coolant, which leads to low heat transfer efficiency. Moreover, to provide enough packing force to keep good contact with the exhaust tank and the coolant tank, the framework required is so robust that the TEGs become too heavy. Therefore, in current study, an automotive TEG was designed which included one exhaust channel, one coolant channel and several TEMs. In the TEG, the TEMs which contacted the exhaust and coolant directly were inserted into the walls of each coolant channel. To evaluate the performance of the automotive TEG, the flow field and temperature field were computed by computational fluid dynamics (CFD). Based on the temperature distribution obtained by CFD and the performance parameters of the modules, the total power generation was obtained by some proved empirical formulas. Compared with conventional automotive TEGs, the power generation per unit volume exhaust was boosted.

  17. Sorption and precipitation of Mn2+ by viable and autoclaved Shewanella putrefaciens: Effect of contact time

    KAUST Repository

    Chubar, Natalia; Visser, Tom; Avramut, Cristina; de Waard, Helen

    2013-01-01

    of pH, bacterial density and metal loading. During a short contact time (3-24h), the adsorptive behaviour of live and dead bacteria toward Mn(II) was sufficiently similar, an observation that was reflected in the studies on adsorption kinetics

  18. Concerns about Appearing Prejudiced Get Under the Skin: Stress Responses to Interracial Contact in the Moment and across Time.

    Science.gov (United States)

    Trawalter, Sophie; Adam, Emma K; Chase-Lansdale, P Lindsay; Richeson, Jennifer A

    2012-05-01

    Many White Americans are concerned about appearing prejudiced. How these concerns affect responses during actual interracial interactions, however, remains understudied. The present work examines stress responses to interracial contact-both in the moment, during interracial interactions (Study 1), and over time as individuals have repeated interracial contact (Study 2). Results of Study 1 revealed that concerns about appearing prejudiced were associated with heightened stress responses during interracial encounters (Study 1). White participants concerned about appearing prejudiced exhibited significant increases in cortisol "stress hormone" levels as well as increases in anxious behavior during interracial but not same-race contact. Participants relatively unconcerned about appearing prejudiced did not exhibit these stress responses. Study 2 examined stress responses to interracial contact over an entire academic year. Results revealed that White participants exhibited shifts in cortisol diurnal rhythms on days after interracial contact. Moreover, participants' cortisol rhythms across the academic year, from fall to spring, were related to their concerns about appearing prejudiced and their interracial contact experiences. Taken together, these data offer the first evidence that chronic concerns about appearing prejudiced are related to short- and longer-term stress responses to interracial contact. Implications for life in diverse spaces are discussed.

  19. Measuring The Contact Resistances Of Photovoltaic Cells

    Science.gov (United States)

    Burger, D. R.

    1985-01-01

    Simple method devised to measure contact resistances of photovoltaic solar cells. Method uses readily available equipment and applicable at any time during life of cell. Enables evaluation of cell contact resistance, contact-end resistance, contact resistivity, sheet resistivity, and sheet resistivity under contact.

  20. Liquid-solid contact measurements using a surface thermocouple temperature probe in atmospheric pool boiling water

    International Nuclear Information System (INIS)

    Lee, L.Y.W.; Chen, J.C.; Nelson, R.A.

    1984-01-01

    Objective was to apply the technique of using a microthermocouple flush-mounted at the boiling surface for the measurement of the local-surface-temperature history in film and transition boiling on high temperature surfaces. From this measurement direct liquid-solid contact in film and transition boiling regimes was observed. In pool boiling of saturated, distilled, deionized water on an aluminum-coated copper surface, the time-averaged, local-liquid-contact fraction increased with decreasing surface superheat. Average contact duration increased monotonically with decreasing surface superheat, while frequency of liquid contact reached a maximum of approx. 50 contacts/s at a surface superheat of approx. 100 K and decreased gradually to 30 contacts/s near the critical heat flux. The liquid-solid contact duration distribution was dominated by short contacts 4 ms at low surface superheats, passing through a relatively flat contact duration distribution at about 80 0 K. Results of this paper indicate that liquid-solid contacts may be the dominant mechanism for energy transfer in the transition boiling process

  1. Reliability of video-based identification of footstrike pattern and video time frame at initial contact in recreational runners

    DEFF Research Database (Denmark)

    Damsted, Camma; Larsen, L H; Nielsen, R.O.

    2015-01-01

    and video time frame at initial contact during treadmill running using two-dimensional (2D) video recordings. METHODS: Thirty-one recreational runners were recorded twice, 1 week apart, with a high-speed video camera. Two blinded raters evaluated each video twice with an interval of at least 14 days....... RESULTS: Kappa values for within-day identification of footstrike pattern revealed intra-rater agreement of 0.83-0.88 and inter-rater agreement of 0.50-0.63. Corresponding figures for between-day identification of footstrike pattern were 0.63-0.69 and 0.41-0.53, respectively. Identification of video time...... in 36% of the identifications (kappa=0.41). The 95% limits of agreement for identification of video time frame at initial contact may, at times, allow for different identification of footstrike pattern. Clinicians should, therefore, be encouraged to continue using clinical 2D video setups for intra...

  2. Direct output feedback control of discrete-time systems

    International Nuclear Information System (INIS)

    Lin, C.C.; Chung, L.L.; Lu, K.H.

    1993-01-01

    An optimal direct output feedback control algorithm is developed for discrete-time systems with the consideration of time delay in control force action. Optimal constant output feedback gains are obtained through variational process such that certain prescribed quadratic performance index is minimized. Discrete-time control forces are then calculated from the multiplication of output measurements by these pre-calculated feedback gains. According to the proposed algorithm, structural system is assured to remain stable even in the presence of time delay. The number of sensors and controllers may be very small as compared with the dimension of states. Numerical results show that direct velocity feedback control is more sensitive to time delay than state feedback but, is still quite effective in reducing the dynamic responses under earthquake excitation. (author)

  3. Effect of Spreading Time on Contact Angle of Nanofluid on the Surface of Stainless Steel AISI 316 and Zircalloy 4

    Science.gov (United States)

    Prajitno, D. H.; Trisnawan, V.; Syarif, D. G.

    2017-05-01

    The solid surface tension plays an important role in the heat and mass transfer system for heat exchanger equipment. In the nuclear power plant industry, the stainless steel AISI 316 and Zircalloy 4 have been used for long time as structure materials. The purpose of the experimental is to study solid state surface tension behavior by measure contact angle Nano fluid contain nano particle alumina on metal surface of stainless steel AISI 316 and Zircalloy 4 by sessile drop method. The experiment is to measure the static contact angle and drop nano fluid contains nano particle alumina on stainless steel 316 and zircalloy 4 with different spreading time from 1 to 30 minute. It was observed that stainless steel 316 and zircalloy 4 lose their hydrophobic properties with increasing elapsed time during drop of nano fluid on the surface of alloy. As a result the contact angle of nano fluid on surface of metal is decrease with increasing elapsed time. While the magnitude diameter of drop nano fluid and wetting surface is increase with increasing elapsed time on the surface of the stainless steel SS 316 and Zircalloy 4.

  4. Experimental study on direct-contact liquid film cooling simulated dense-array solar cells in high concentrating photovoltaic system

    International Nuclear Information System (INIS)

    Wang, Yiping; Shi, Xusheng; Huang, Qunwu; Cui, Yong; Kang, Xue

    2017-01-01

    Highlights: • Direct-contact liquid film cooling dense-array solar cells was first proposed. • Average temperature was controlled well below 80 °C. • The maximum temperature difference was less than 10 °C. • The heat transfer coefficient reached up to 11.91 kW/(m"2·K) under 589X. - Abstract: This paper presented a new method of cooling dense-array solar cells in high concentrating photovoltaic system by direct-contact liquid film, and water was used as working fluid. An electric heating plate was designed to simulate the dense-array solar cells in high concentrating photovoltaic system. The input power of electric heating plate simulated the concentration ratios. By heat transfer experiments, the effect of water temperatures and flow rates on heat transfer performance was investigated. The results indicated that: the average temperature of simulated solar cells was controlled well below 80 °C under water temperature of 30 °C and flow rate of 300 L/h when concentration ratio ranged between 300X and 600X. The maximum temperature difference among temperature measurement points was less than 10 °C, which showed the temperature distribution was well uniform. The heat transfer coefficient reached up to 11.91 kW/(m"2·K) under concentration ratio of 589X. To improve heat transfer performance and obtain low average temperature of dense-array solar cells, lower water temperature and suitable water flow rate are preferred.

  5. Preclinical, fluorescence and diffuse optical tomography: non-contact instrumentation, modeling and time-resolved 3D reconstruction

    International Nuclear Information System (INIS)

    Nouizi, F.

    2011-09-01

    Time-Resolved Diffuse Optical Tomography (TR-DOT) is a new non-invasive imaging technique increasingly used in the clinical and preclinical fields. It yields optical absorption and scattering maps of the explored organs, and related physiological parameters. Time-Resolved Fluorescence Diffuse Optical Tomography (TR-FDOT) is based on the detection of fluorescence photons. It provides spatio-temporal maps of fluorescent probe concentrations and life times, and allows access to metabolic and molecular imaging which is important for diagnosis and therapeutic monitoring, particularly in oncology. The main goal of this thesis was to reconstruct 3D TR-DOT/TR-FDOT images of small animals using time-resolved optical technology. Data were acquired using optical fibers fixed around the animal without contact with its surface. The work was achieved in four steps: 1)- Setting up an imaging device to record the 3D coordinates of an animal's surface; 2)- Modeling the no-contact approach to solve the forward problem; 3)- Processing of the measured signals taking into account the impulse response of the device; 4)- Implementation of a new image reconstruction method based on a selection of carefully chosen points. As a result, good-quality 3D optical images were obtained owing to reduced cross-talk between absorption and scattering. Moreover, the computation time was cut down, compared to full-time methods using whole temporal profiles. (author)

  6. Effect of Virtual Reality Exposure and Aural Stimuli on Eye Contact, Directional Focus, and Focus of Attention of Novice Wind Band Conductors

    Science.gov (United States)

    Orman, Evelyn K.

    2016-01-01

    This study examined the effects of virtual reality immersion with audio on eye contact, directional focus and focus of attention for novice wind band conductors. Participants (N = 34) included a control group (n = 12) and two virtual reality groups with (n = 10) and without (n = 12) head tracking. Participants completed conducting/score study…

  7. Using customer contact centres as relationship marketing instruments

    NARCIS (Netherlands)

    van der Aa, Zanna; Bloemer, Josée; Henseler, Jörg

    2015-01-01

    This article investigates whether, to what extent and how customer contact centres influence customer–firm relationships through customer contact centre quality. The proposed model compiles direct and indirect effects of this form of quality on focal relationship marketing constructs, including

  8. Improvement of direct contact condensation model of relap5/mod3.1 for passive high-pressure injection system

    International Nuclear Information System (INIS)

    Sang, Il Lee; Hee, Cheon No

    1998-01-01

    A simple set of the transition criterion of the condensation regimes and the heat transfer coefficients on the direct contact condensation in the core makeup tank was developed, and implemented in RELAP5/MOD3.1. The condensation regimes were divided into two ones: supply limit and condensation limit. In modeling the transition criterion between two regimes, a large-eddy model developed by Theofanous was used. The modified code better predicted the experiments on the core makeup tank using small scale test facility than the original code did

  9. Proposed ICDRG Classification of the Clinical Presentation of Contact Allergy

    DEFF Research Database (Denmark)

    Pongpairoj, Korbkarn; Ale, Iris; Andersen, Klaus Ejner

    2016-01-01

    The International Contact Dermatitis Research Group proposes a classification for the clinical presentation of contact allergy. The classification is based primarily on the mode of clinical presentation. The categories are direct exposure/contact dermatitis, mimicking or exacerbation of preexisting....../mucosal symptoms, oral contact dermatitis, erythroderma/exfoliative dermatitis, minor forms of presentation, and extracutaneous manifestations....

  10. Parotid gland tumours: MR tractography to assess contact with the facial nerve.

    Science.gov (United States)

    Attyé, Arnaud; Karkas, Alexandre; Troprès, Irène; Roustit, Matthieu; Kastler, Adrian; Bettega, Georges; Lamalle, Laurent; Renard, Félix; Righini, Christian; Krainik, Alexandre

    2016-07-01

    To assess the feasibility of intraparotid facial nerve (VIIn) tractographic reconstructions in estimating the presence of a contact between the VIIn and the tumour, in patients requiring surgical resection of parotid tumours. Patients underwent MR scans with VIIn tractography calculated with the constrained spherical deconvolution model. The parameters of the diffusion sequence were: b-value of 1000 s/mm(2); 32 directions; voxel size: 2 mm isotropic; scan time: 9'31'. The potential contacts between VIIn branches and tumours were estimated with different initial fractional anisotropy (iFA) cut-offs compared to surgical data. Surgeons were blinded to the tractography reconstructions and identified both nerves and contact with tumours using nerve stimulation and reference photographs. Twenty-six patients were included in this study and the mean patient age was 55.2 years. Surgical direct assessment of VIIn allowed identifying 0.1 as the iFA threshold with the best sensitivity to detect tumour contact. In all patients with successful VIIn identification by tractography, surgeons confirmed nerve courses as well as lesion location in parotid glands. Mean VIIn branch FA values were significantly lower in cases with tumour contact (t-test; p ≤ 0.01). This study showed the feasibility of intraparotid VIIn tractography to identify nerve contact with parotid tumours. • Diffusion imaging is an efficient method for highlighting the intraparotid VIIn. • Visualization of the VIIn may help to better manage patients before surgery. • We bring new insights to future trials for patients with VIIn dysfunction. • We aimed to provide radio-anatomical references for further studies.

  11. CMOS Time-Resolved, Contact, and Multispectral Fluorescence Imaging for DNA Molecular Diagnostics

    Directory of Open Access Journals (Sweden)

    Nan Guo

    2014-10-01

    Full Text Available Instrumental limitations such as bulkiness and high cost prevent the fluorescence technique from becoming ubiquitous for point-of-care deoxyribonucleic acid (DNA detection and other in-field molecular diagnostics applications. The complimentary metal-oxide-semiconductor (CMOS technology, as benefited from process scaling, provides several advanced capabilities such as high integration density, high-resolution signal processing, and low power consumption, enabling sensitive, integrated, and low-cost fluorescence analytical platforms. In this paper, CMOS time-resolved, contact, and multispectral imaging are reviewed. Recently reported CMOS fluorescence analysis microsystem prototypes are surveyed to highlight the present state of the art.

  12. CONTACT RESISTANCE MODELING

    Directory of Open Access Journals (Sweden)

    S. V. LOSKUTOV

    2018-05-01

    Full Text Available Purpose. To determine the contribution of the real contact spots distribution in the total conductivity of the conductors contact. Methodology. The electrical contact resistance research was carried out on models. The experimental part of this work was done on paper with a graphite layer with membranes (the first type and conductive liquids with discrete partitions (the second type. Findings. It is shown that the contact electrical resistance is mainly determined by the real area of metal contact. The experimental dependence of the electrical resistance of the second type model on the distance between the electrodes and the potential distribution along the sample surface for the first type model were obtained. The theoretical model based on the principle of electric field superposition was considered. The dependences obtained experimentally and calculated by using the theoretical model are in good agreement. Originality. The regularity of the electrical contact resistance formation on a large number of membranes was researched for the first time. A new model of discrete electrical contact based on the liquid as the conducting environment with nuclear membrane partitions was developed. The conclusions of the additivity of contact and bulk electrical resistance were done. Practical value. Based on these researches, a new experimental method of kinetic macroidentation that as a parameter of the metal surface layer deformation uses the real contact area was developed. This method allows to determine the value of average contact stresses, yield point, change of the stress on the depth of deformation depending on the surface treatment.

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ... MD, professor of ophthalmology at Case Western Reserve University in Cleveland. "This is far ... Use Facts About Colored Contacts and Halloween Safety Colored ...

  14. In the eye of the beholder: eye contact increases resistance to persuasion.

    Science.gov (United States)

    Chen, Frances S; Minson, Julia A; Schöne, Maren; Heinrichs, Markus

    2013-11-01

    Popular belief holds that eye contact increases the success of persuasive communication, and prior research suggests that speakers who direct their gaze more toward their listeners are perceived as more persuasive. In contrast, we demonstrate that more eye contact between the listener and speaker during persuasive communication predicts less attitude change in the direction advocated. In Study 1, participants freely watched videos of speakers expressing various views on controversial sociopolitical issues. Greater direct gaze at the speaker's eyes was associated with less attitude change in the direction advocated by the speaker. In Study 2, we instructed participants to look at either the eyes or the mouths of speakers presenting arguments counter to participants' own attitudes. Intentionally maintaining direct eye contact led to less persuasion than did gazing at the mouth. These findings suggest that efforts at increasing eye contact may be counterproductive across a variety of persuasion contexts.

  15. A novel MEMS inertial switch with a reinforcing rib structure and electrostatic power assist to prolong the contact time

    Science.gov (United States)

    Li, Jian; Wang, Yan; Yang, Zhuoqing; Ding, Guifu; Zhao, Xiaolin; Wang, Hong

    2018-03-01

    The MEMS inertial switch is widely used in various industries owing to its advantage of small size, high integration, low power consumption and low costs, especially in the timing of Internet of things, such as toys, handheld devices, accessories and vibration testing. This paper provided a novel inertial switch with a reinforcing rib structure and electrostatic power assist. The designed inertial switch can reduce the complexity of the post-processing circuit and broaden its application prospect. The continuous electrostatic force can extend the contact time of the designed inertia switch before the leakage of electricity ends. The moving electrode with a reinforcing rib structure can effectively restrain the bending of the lower surface of moving electrode caused by residual stress. The array-type fixed electrode can ensure stable contact between the electrodes when the device is sensitive to external shocks. The dynamic displacement-time curve can be simulated by the COMSOL finite element simulation software. The laminated plating process is used to produce the designed inertial switch and the drop hammer acceleration monitoring system is used to test the fabricated device. The results indicate that, compared with the traditional design, the bouncing phenomenon can be prevented and extend the contact time to 336μs.

  16. Response function of a moving contact line

    Science.gov (United States)

    Perrin, H.; Belardinelli, D.; Sbragaglia, M.; Andreotti, B.

    2018-04-01

    The hydrodynamics of a liquid-vapor interface in contact with a heterogeneous surface is largely impacted by the presence of defects at the smaller scales. Such defects introduce morphological disturbances on the contact line and ultimately determine the force exerted on the wedge of liquid in contact with the surface. From the mathematical point of view, defects introduce perturbation modes, whose space-time evolution is governed by the interfacial hydrodynamic equations of the contact line. In this paper we derive the response function of the contact line to such generic perturbations. The contact line response may be used to design simplified one-dimensional time-dependent models accounting for the complexity of interfacial flows coupled to nanoscale defects, yet offering a more tractable mathematical framework to explore contact line motion through a disordered energy landscape.

  17. Chemical discrimination of lubricant marketing types using direct analysis in real time time-of-flight mass spectrometry.

    Science.gov (United States)

    Maric, Mark; Harvey, Lauren; Tomcsak, Maren; Solano, Angelique; Bridge, Candice

    2017-06-30

    In comparison to other violent crimes, sexual assaults suffer from very low prosecution and conviction rates especially in the absence of DNA evidence. As a result, the forensic community needs to utilize other forms of trace contact evidence, like lubricant evidence, in order to provide a link between the victim and the assailant. In this study, 90 personal bottled and condom lubricants from the three main marketing types, silicone-based, water-based and condoms, were characterized by direct analysis in real time time of flight mass spectrometry (DART-TOFMS). The instrumental data was analyzed by multivariate statistics including hierarchal cluster analysis, principal component analysis, and linear discriminant analysis. By interpreting the mass spectral data with multivariate statistics, 12 discrete groupings were identified, indicating inherent chemical diversity not only between but within the three main marketing groups. A number of unique chemical markers, both major and minor, were identified, other than the three main chemical components (i.e. PEG, PDMS and nonoxynol-9) currently used for lubricant classification. The data was validated by a stratified 20% withheld cross-validation which demonstrated that there was minimal overlap between the groupings. Based on the groupings identified and unique features of each group, a highly discriminating statistical model was then developed that aims to provide the foundation for the development of a forensic lubricant database that may eventually be applied to casework. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Contact detection for nanomanipulation in a scanning electron microscope

    Energy Technology Data Exchange (ETDEWEB)

    Ru, Changhai, E-mail: rchhai@gmail.com [Automation College, Harbin Engineering University, Harbin 150001 (China); Robotics and Microsystems Center, Soochow University, Jiangsu 215021 (China); To, Steve, E-mail: Steve.to@utoronto.ca [Department of Mechanical and Industry Engineering, University of Toronto, Ontario, Canada M5S3G8 (Canada)

    2012-07-15

    Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000 Multiplication-Sign magnification while inducing little end-effector damage. -- Highlights: Black-Right-Pointing-Pointer We presents a simple method for obtaining the depth information in SEM-based nanomanipulation. Black-Right-Pointing-Pointer Detecting contact between an end-effector and a target surface using SEM as a vision sensor. Black-Right-Pointing-Pointer Additional touch/force sensors or specialized hardware need not be added. Black-Right-Pointing-Pointer Achieved high repeatability and accuracy. Black-Right-Pointing-Pointer Complete automatic contact detection within typically 60 s.

  19. On the real-time estimation of the wheel-rail contact force by means of a new nonlinear estimator design model

    Science.gov (United States)

    Strano, Salvatore; Terzo, Mario

    2018-05-01

    The dynamics of the railway vehicles is strongly influenced by the interaction between the wheel and the rail. This kind of contact is affected by several conditioning factors such as vehicle speed, wear, adhesion level and, moreover, it is nonlinear. As a consequence, the modelling and the observation of this kind of phenomenon are complex tasks but, at the same time, they constitute a fundamental step for the estimation of the adhesion level or for the vehicle condition monitoring. This paper presents a novel technique for the real time estimation of the wheel-rail contact forces based on an estimator design model that takes into account the nonlinearities of the interaction by means of a fitting model functional to reproduce the contact mechanics in a wide range of slip and to be easily integrated in a complete model based estimator for railway vehicle.

  20. Experimental and Analytical Study of Lead-Bismuth-Water Direct Contact Boiling Two-Phase Flow

    Science.gov (United States)

    Novitrian; Dostal, Vaclav; Takahashi, Minoru

    The characteristics of lead-bismuth(Pb-Bi)-water boiling two-phase flow were investigated experimentally and analytically using a Pb-Bi-water direct contact boiling two-phase flow loop. Pb-Bi flow rates and void fraction were measured in a vertical circular tube at conditions of system pressure 7MPa, liquid metal temperature 460°C and injected water temperature 220°C. The drift-flux model with the assumption that bubble sizes were dependent on the fluid surface tension and the density ratio of Pb-Bi to steam-water mixture was chosen and modified by the best fit to the measured void fraction. Pb-Bi flow rates were analytically estimated using balance condition between buoyancy force and pressure losses, where the buoyancy force was calculated from void fraction estimated using the modified drift-flux model. The deviation of the analytical results of the flow rates from the experimental ones was less than 10%.

  1. Pseudophakodonesis and corneal endothelial contact: direct observations by high-speed cinematography.

    Science.gov (United States)

    Jacobs, P M; Cheng, H; Price, N C

    1983-10-01

    High-speed cinematography was used to observe the movement of Federov type I lens implants within the anterior chamber. Our measurements suggest that in most patients contact between the lens implant and corneal endothelium does not occur.

  2. Biomechanical factors associated with time to complete a change of direction cutting maneuver.

    Science.gov (United States)

    Marshall, Brendan M; Franklyn-Miller, Andrew D; King, Enda A; Moran, Kieran A; Strike, Siobhán C; Falvey, Éanna C

    2014-10-01

    Cutting ability is an important aspect of many team sports, however, the biomechanical determinants of cutting performance are not well understood. This study aimed to address this issue by identifying the kinetic and kinematic factors correlated with the time to complete a cutting maneuver. In addition, an analysis of the test-retest reliability of all biomechanical measures was performed. Fifteen (n = 15) elite multidirectional sports players (Gaelic hurling) were recruited, and a 3-dimensional motion capture analysis of a 75° cut was undertaken. The factors associated with cutting time were determined using bivariate Pearson's correlations. Intraclass correlation coefficients (ICCs) were used to examine the test-retest reliability of biomechanical measures. Five biomechanical factors were associated with cutting time (2.28 ± 0.11 seconds): peak ankle power (r = 0.77), peak ankle plantar flexor moment (r = 0.65), range of pelvis lateral tilt (r = -0.54), maximum thorax lateral rotation angle (r = 0.51), and total ground contact time (r = -0.48). Intraclass correlation coefficient scores for these 5 factors, and indeed for the majority of the other biomechanical measures, ranged from good to excellent (ICC >0.60). Explosive force production about the ankle, pelvic control during single-limb support, and torso rotation toward the desired direction of travel were all key factors associated with cutting time. These findings should assist in the development of more effective training programs aimed at improving similar cutting performances. In addition, test-retest reliability scores were generally strong, therefore, motion capture techniques seem well placed to further investigate the determinants of cutting ability.

  3. The effect of contact precautions on healthcare worker activity in acute care hospitals.

    Science.gov (United States)

    Morgan, Daniel J; Pineles, Lisa; Shardell, Michelle; Graham, Margaret M; Mohammadi, Shahrzad; Forrest, Graeme N; Reisinger, Heather S; Schweizer, Marin L; Perencevich, Eli N

    2013-01-01

    Contact precautions are a cornerstone of infection prevention but have also been associated with less healthcare worker (HCW) contact and adverse events. We studied how contact precautions modified HCW behavior in 4 acute care facilities. Prospective cohort study. Four acute care facilities in the United States performing active surveillance for methicillin-resistant Staphylococcus aureus. Trained observers performed "secret shopper" monitoring of HCW activities during routine care, using a standardized collection tool and fixed 1-hour observation periods. A total of 7,743 HCW visits were observed over 1,989 hours. Patients on contact precautions had 36.4% fewer hourly HCW visits than patients not on contact precautions (2.78 vs 4.37 visits per hour; [Formula: see text]) as well as 17.7% less direct patient contact time with HCWs (13.98 vs 16.98 minutes per hour; [Formula: see text]). Patients on contact precautions tended to have fewer visitors (23.6% fewer; [Formula: see text]). HCWs were more likely to perform hand hygiene on exiting the room of a patient on contact precautions (63.2% vs 47.4% in rooms of patients not on contact precautions; [Formula: see text]). Contact precautions were found to be associated with activities likely to reduce transmission of resistant pathogens, such as fewer visits and better hand hygiene at exit, while exposing patients on contact precautions to less HCW contact, less visitor contact, and potentially other unintended outcomes.

  4. Interaction dynamics of two diffusing particles: contact times and influence of nearby surfaces.

    Science.gov (United States)

    Tränkle, B; Ruh, D; Rohrbach, A

    2016-03-14

    Interactions of diffusing particles are governed by hydrodynamics on different length and timescales. The local hydrodynamics can be influenced substantially by simple interfaces. Here, we investigate the interaction dynamics of two micron-sized spheres close to plane interfaces to mimic more complex biological systems or microfluidic environments. Using scanned line optical tweezers and fast 3D interferometric particle tracking, we are able to track the motion of each bead with precisions of a few nanometers and at a rate of 10 kilohertz. From the recorded trajectories, all spatial and temporal information is accessible. This way, we measure diffusion coefficients for two coupling particles at varying distances h to one or two glass interfaces. We analyze their coupling strength and length by cross-correlation analysis relative to h and find a significant decrease in the coupling length when a second particle diffuses nearby. By analysing the times the particles are in close contact, we find that the influence of nearby surfaces and interaction potentials reduce the diffusivity strongly, although we found that the diffusivity hardly affects the contact times and the binding probability between the particles. All experimental results are compared to a theoretical model, which is based on the number of possible diffusion paths following the Catalan numbers and a diffusion probability, which is biased by the spheres' surface potential. The theoretical and experimental results agree very well and therefore enable a better understanding of hydrodynamically coupled interaction processes.

  5. Detection of polydimethylsiloxanes transferred from silicone-coated parchment paper to baked goods using direct analysis in real time mass spectrometry.

    Science.gov (United States)

    Jakob, Andreas; Crawford, Elizabeth A; Gross, Jürgen H

    2016-04-01

    The non-stick properties of parchment papers are achieved by polydimethylsiloxane (PDMS) coatings. During baking, PDMS can thus be extracted from the silicone-coated parchment into the baked goods. Positive-ion direct analysis in real time (DART) mass spectrometry (MS) is highly efficient for the analysis of PDMS. A DART-SVP source was coupled to a quadrupole-time-of-flight mass spectrometer to detect PDMS on the contact surface of baked goods after use of silicone-coated parchment papers. DART spectra from the bottom surface of baked cookies and pizzas exhibited signals because of PDMS ions of the general formula [(C2H6SiO)n  + NH4 ](+) in the m/z 800-1900 range. Copyright © 2016 John Wiley & Sons, Ltd.

  6. Pseudophakodonesis and corneal endothelial contact: direct observations by high-speed cinematography.

    Science.gov (United States)

    Jacobs, P M; Cheng, H; Price, N C

    1983-01-01

    High-speed cinematography was used to observe the movement of Federov type I lens implants within the anterior chamber. Our measurements suggest that in most patients contact between the lens implant and corneal endothelium does not occur. Images PMID:6615750

  7. Contact angle hysteresis on superhydrophobic stripes.

    Science.gov (United States)

    Dubov, Alexander L; Mourran, Ahmed; Möller, Martin; Vinogradova, Olga I

    2014-08-21

    We study experimentally and discuss quantitatively the contact angle hysteresis on striped superhydrophobic surfaces as a function of a solid fraction, ϕS. It is shown that the receding regime is determined by a longitudinal sliding motion of the deformed contact line. Despite an anisotropy of the texture the receding contact angle remains isotropic, i.e., is practically the same in the longitudinal and transverse directions. The cosine of the receding angle grows nonlinearly with ϕS. To interpret this we develop a theoretical model, which shows that the value of the receding angle depends both on weak defects at smooth solid areas and on the strong defects due to the elastic energy of the deformed contact line, which scales as ϕS(2)lnϕS. The advancing contact angle was found to be anisotropic, except in a dilute regime, and its value is shown to be determined by the rolling motion of the drop. The cosine of the longitudinal advancing angle depends linearly on ϕS, but a satisfactory fit to the data can only be provided if we generalize the Cassie equation to account for weak defects. The cosine of the transverse advancing angle is much smaller and is maximized at ϕS ≃ 0.5. An explanation of its value can be obtained if we invoke an additional energy due to strong defects in this direction, which is shown to be caused by the adhesion of the drop on solid sectors and is proportional to ϕS(2). Finally, the contact angle hysteresis is found to be quite large and generally anisotropic, but it becomes isotropic when ϕS ≤ 0.2.

  8. Direct Measurement of Static and Dynamic Contact Angles Using a Random Micromodel Considering Geological CO2 Sequestration

    Directory of Open Access Journals (Sweden)

    Mohammad Jafari

    2017-12-01

    Full Text Available The pore-level two-phase fluids flow mechanism needs to be understood for geological CO2 sequestration as a solution to mitigate anthropogenic emission of carbon dioxide. Capillary pressure at the interface of water–CO2 influences CO2 injectability, capacity, and safety of the storage system. Wettability usually measured by contact angle is always a major uncertainty source among important parameters affecting capillary pressure. The contact angle is mostly determined on a flat surface as a representative of the rock surface. However, a simple and precise method for determining in situ contact angle at pore-scale is needed to simulate fluids flow in porous media. Recent progresses in X-ray tomography technique has provided a robust way to measure in situ contact angle of rocks. However, slow imaging and complicated image processing make it impossible to measure dynamic contact angle. In the present paper, a series of static and dynamic contact angles as well as contact angles on flat surface were measured inside a micromodel with random pattern of channels under high pressure condition. Our results showed a wide range of pore-scale contact angles, implying complexity of the pore-scale contact angle even in a highly smooth and chemically homogenous glass micromodel. Receding contact angle (RCA showed more reproducibility compared to advancing contact angle (ACA and static contact angle (SCA for repeating tests and during both drainage and imbibition. With decreasing pore size, RCA was increased. The hysteresis of the dynamic contact angle (ACA–RCA was higher at pressure of one megapascal in comparison with that at eight megapascals. The CO2 bubble had higher mobility at higher depths due to lower hysteresis which is unfavorable. CO2 bubbles resting on the flat surface of the micromodel channel showed a wide range of contact angles. They were much higher than reported contact angle values observed with sessile drop or captive bubble tests on a

  9. ALLERGIC CONTACT DERMATITIS

    Directory of Open Access Journals (Sweden)

    Trisna Yuliharti Tersinanda

    2013-07-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE Allergic contact dermatitis is an immunologic reaction that tends to involve the surrounding skin and may even spread beyond affected sites. This skin disease is one of the more frequent, and costly dermatologic problems. Recent data from United Kingdom and United States suggest that the percentage of occupational contact dermatitis due to allergy may be much higher, thus raising the economic impact of occupational allergic contact dermatitis. There is not enough data about the epidemiology of allergic contact dermatitis in Indonesia, however based on research that include beautician in Denpasar, about 27,6 percent had side effect of cosmetics, which is 25,4 percent of it manifested as allergic contact dermatitis. Diagnosis of allergic contact dermatitis is based on anamnesis, physical examination, patch test, and this disease should be distinguished from other eczematous skin disease. The management is prevention of allergen exposure, symptomatic treatment, and physicochemical barrier /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin-top:0in; mso-para-margin-right:0in; mso-para-margin-bottom:10.0pt; mso-para-margin-left:0in; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  10. Characterization of a time-resolved non-contact scanning diffuse optical imaging system exploiting fast-gated single-photon avalanche diode detection

    Energy Technology Data Exchange (ETDEWEB)

    Di Sieno, Laura, E-mail: laura.disieno@polimi.it; Dalla Mora, Alberto; Contini, Davide [Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Wabnitz, Heidrun; Macdonald, Rainer [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany); Pifferi, Antonio [Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Piazza Leonardo da Vinci 32, 20133 Milano (Italy); Mazurenka, Mikhail [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany); Hannoversches Zentrum für Optische Technologien, Nienburger Str. 17, 30167 Hannover (Germany); Hoshi, Yoko [Department of Biomedical Optics, Medical Photonics Research Center, Hamamatsu University School of Medicine, Hamamatsu 431-3192 (Japan); Boso, Gianluca; Tosi, Alberto [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Becker, Wolfgang [Becker and Hickl GmbH, Nahmitzer Damm 30, 12277 Berlin (Germany); Martelli, Fabrizio [Dipartimento di Fisica e Astronomia dell’Università degli Studi di Firenze, Via G. Sansone 1, Sesto Fiorentino, Firenze 50019 (Italy)

    2016-03-15

    We present a system for non-contact time-resolved diffuse reflectance imaging, based on small source-detector distance and high dynamic range measurements utilizing a fast-gated single-photon avalanche diode. The system is suitable for imaging of diffusive media without any contact with the sample and with a spatial resolution of about 1 cm at 1 cm depth. In order to objectively assess its performances, we adopted two standardized protocols developed for time-domain brain imagers. The related tests included the recording of the instrument response function of the setup and the responsivity of its detection system. Moreover, by using liquid turbid phantoms with absorbing inclusions, depth-dependent contrast and contrast-to-noise ratio as well as lateral spatial resolution were measured. To illustrate the potentialities of the novel approach, the characteristics of the non-contact system are discussed and compared to those of a fiber-based brain imager.

  11. Characterization of a time-resolved non-contact scanning diffuse optical imaging system exploiting fast-gated single-photon avalanche diode detection

    International Nuclear Information System (INIS)

    Di Sieno, Laura; Dalla Mora, Alberto; Contini, Davide; Wabnitz, Heidrun; Macdonald, Rainer; Pifferi, Antonio; Mazurenka, Mikhail; Hoshi, Yoko; Boso, Gianluca; Tosi, Alberto; Becker, Wolfgang; Martelli, Fabrizio

    2016-01-01

    We present a system for non-contact time-resolved diffuse reflectance imaging, based on small source-detector distance and high dynamic range measurements utilizing a fast-gated single-photon avalanche diode. The system is suitable for imaging of diffusive media without any contact with the sample and with a spatial resolution of about 1 cm at 1 cm depth. In order to objectively assess its performances, we adopted two standardized protocols developed for time-domain brain imagers. The related tests included the recording of the instrument response function of the setup and the responsivity of its detection system. Moreover, by using liquid turbid phantoms with absorbing inclusions, depth-dependent contrast and contrast-to-noise ratio as well as lateral spatial resolution were measured. To illustrate the potentialities of the novel approach, the characteristics of the non-contact system are discussed and compared to those of a fiber-based brain imager.

  12. Direct time-domain techniques for transient radiation and scattering

    International Nuclear Information System (INIS)

    Miller, E.K.; Landt, J.A.

    1976-01-01

    A tutorial introduction to transient electromagnetics, focusing on direct time-domain techniques, is presented. Physical, mathematical, numerical, and experimental aspects of time-domain methods, with emphasis on wire objects excited as antennas or scatters are examined. Numerous computed examples illustrate the characteristics of direct time-domain procedures, especially where they may offer advantages over procedures in the more familiar frequency domain. These advantages include greater solution efficiency for many types of problems, the ability to handle nonlinearities, improved physical insight and interpretability, availability of wide-band information from a single calculation, and the possibility of isolating interactions among various parts of an object using time-range gating

  13. Fabricating customized hydrogel contact lens

    Science.gov (United States)

    Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.

    2016-10-01

    Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.

  14. An ultra-bright white LED based non-contact skin cancer imaging system with polarization control

    Science.gov (United States)

    Günther, A.; Basu, C.; Roth, B.; Meinhardt-Wollweber, M.

    2013-06-01

    Early detection and excision of melanoma skin cancer is crucial for a successful therapy. Dermoscopy in direct contact with the skin is routinely used for inspection, but screening is time consuming for high-risk patients with a large number of nevi. Features like symmetry, border, color and most importantly changes like growth or depigmentation of a nevus may indicate malignancy. We present a non-contact remote imaging system for human melanocytic nevi with homogenous illumination by an ultra-bright white LED. The advantage compared to established dermoscopy systems requiring direct skin contact is that deformation of raised nevi is avoided and full-body scans of the patients may time-efficiently be obtained while they are in a lying, comfortable position. This will ultimately allow for automated screening in the future. In addition, calibration of true color rendering, which is essential for distinguishing between benign and malignant lesions and to ensure reproducibility and comparison between individual check-ups in order to follow nevi evolution is implemented as well as suppression of specular highlights on the skin surface by integration of polarizing filters. Important features of the system which will be crucial for future integration into automated systems are the possibility to record images without artifacts in combination with short exposure times which both reduce image blurring caused by patient motion.

  15. Frictional Compliant Haptic Contact and Deformation of Soft Objects

    Directory of Open Access Journals (Sweden)

    Naci Zafer

    2016-05-01

    Full Text Available This paper is concerned with compliant haptic contact and deformation of soft objects. A human soft fingertip model is considered to act as the haptic interface and is brought into contact with and deforms a discrete surface. A nonlinear constitutive law is developed in predicting normal forces and, for the haptic display of surface texture, motions along the surface are also resisted at various rates by accounting for dynamic Lund-Grenoble (LuGre frictional forces. For the soft fingertip to apply forces over an area larger than a point, normal and frictional forces are distributed around the soft fingertip contact location on the deforming surface. The distribution is realized based on a kernel smoothing function and by a nonlinear spring-damper net around the contact point. Experiments conducted demonstrate the accuracy and effectiveness of our approach in real-time haptic rendering of a kidney surface. The resistive (interaction forces are applied at the user fingertip bone edge. A 3-DoF parallel robotic manipulator equipped with a constraint based controller is used for the implementation. By rendering forces both in lateral and normal directions, the designed haptic interface system allows the user to realistically feel both the geometrical and mechanical (nonlinear properties of the deforming kidney.

  16. EpiContactTrace: an R-package for contact tracing during livestock disease outbreaks and for risk-based surveillance.

    Science.gov (United States)

    Nöremark, Maria; Widgren, Stefan

    2014-03-17

    During outbreak of livestock diseases, contact tracing can be an important part of disease control. Animal movements can also be of relevance for risk-based surveillance and sampling, i.e. both when assessing consequences of introduction or likelihood of introduction. In many countries, animal movement data are collected with one of the major objectives to enable contact tracing. However, often an analytical step is needed to retrieve appropriate information for contact tracing or surveillance. In this study, an open source tool was developed to structure livestock movement data to facilitate contact-tracing in real time during disease outbreaks and for input in risk-based surveillance and sampling. The tool, EpiContactTrace, was written in the R-language and uses the network parameters in-degree, out-degree, ingoing contact chain and outgoing contact chain (also called infection chain), which are relevant for forward and backward tracing respectively. The time-frames for backward and forward tracing can be specified independently and search can be done on one farm at a time or for all farms within the dataset. Different outputs are available; datasets with network measures, contacts visualised in a map and automatically generated reports for each farm either in HTML or PDF-format intended for the end-users, i.e. the veterinary authorities, regional disease control officers and field-veterinarians. EpiContactTrace is available as an R-package at the R-project website (http://cran.r-project.org/web/packages/EpiContactTrace/). We believe this tool can help in disease control since it rapidly can structure essential contact information from large datasets. The reproducible reports make this tool robust and independent of manual compilation of data. The open source makes it accessible and easily adaptable for different needs.

  17. Two gap superconductivity in Ba{sub 0.55}K{sub 0.45}Fe{sub 2}As{sub 2} single crystals studied by the directional point-contact Andreev reflection spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Szabo, P.; Pribulova, Z. [Centre of Low Temperature Physics, IEP Slovak Academy of Sciences and P.J.Safarik University, Watsonova 47, SK-04001 Kosice (Slovakia); Pristas, G.; Bud' ko, S.L.; Canfield, P.C. [Ames Laboratory and Iowa State University, Ames, IA 50011 (United States); Samuely, P., E-mail: samuely@saske.s [Centre of Low Temperature Physics, IEP Slovak Academy of Sciences and P.J.Safarik University, Watsonova 47, SK-04001 Kosice (Slovakia)

    2009-10-15

    First directional point-contact Andreev reflection spectroscopy on the Ba{sub 0.55}K{sub 0.45}Fe{sub 2}As{sub 2} single crystals is presented. The spectra show significant differences when measured in the ab plane in comparison with those measured in the c direction. In the latter case no traces of superconducting energy gap could be found, just a reduced point-contact conductance persisting up to about 100 K and indicating reduced density of states. On the other hand within the ab plane two nodeless superconducting energy gaps DELTA{sub S}approx2-5 meV and DELTA{sub L}approx9-11 meV are detected.

  18. Dynamic Contact Angle at the Nanoscale: A Unified View.

    Science.gov (United States)

    Lukyanov, Alex V; Likhtman, Alexei E

    2016-06-28

    Generation of a dynamic contact angle in the course of wetting is a fundamental phenomenon of nature. Dynamic wetting processes have a direct impact on flows at the nanoscale, and therefore, understanding them is exceptionally important to emerging technologies. Here, we reveal the microscopic mechanism of dynamic contact angle generation. It has been demonstrated using large-scale molecular dynamics simulations of bead-spring model fluids that the main cause of local contact angle variations is the distribution of microscopic force acting at the contact line region. We were able to retrieve this elusive force with high accuracy. It has been directly established that the force distribution can be solely predicted on the basis of a general friction law for liquid flow at solid surfaces by Thompson and Troian. The relationship with the friction law provides both an explanation of the phenomenon of dynamic contact angle and a methodology for future predictions. The mechanism is intrinsically microscopic, universal, and irreducible and is applicable to a wide range of problems associated with wetting phenomena.

  19. Direct Characterization of Ultrafast Energy-Time Entangled Photon Pairs.

    Science.gov (United States)

    MacLean, Jean-Philippe W; Donohue, John M; Resch, Kevin J

    2018-02-02

    Energy-time entangled photons are critical in many quantum optical phenomena and have emerged as important elements in quantum information protocols. Entanglement in this degree of freedom often manifests itself on ultrafast time scales, making it very difficult to detect, whether one employs direct or interferometric techniques, as photon-counting detectors have insufficient time resolution. Here, we implement ultrafast photon counters based on nonlinear interactions and strong femtosecond laser pulses to probe energy-time entanglement in this important regime. Using this technique and single-photon spectrometers, we characterize all the spectral and temporal correlations of two entangled photons with femtosecond resolution. This enables the witnessing of energy-time entanglement using uncertainty relations and the direct observation of nonlocal dispersion cancellation on ultrafast time scales. These techniques are essential to understand and control the energy-time degree of freedom of light for ultrafast quantum optics.

  20. Shorter Ground Contact Time and Better Running Economy: Evidence From Female Kenyan Runners.

    Science.gov (United States)

    Mooses, Martin; Haile, Diresibachew W; Ojiambo, Robert; Sang, Meshack; Mooses, Kerli; Lane, Amy R; Hackney, Anthony C

    2018-06-25

    Mooses, M, Haile, DW, Ojiambo, R, Sang, M, Mooses, K, Lane, AR, and Hackney, AC. Shorter ground contact time and better running economy: evidence from female Kenyan runners. J Strength Cond Res XX(X): 000-000, 2018-Previously, it has been concluded that the improvement in running economy (RE) might be considered as a key to the continued improvement in performance when no further increase in V[Combining Dot Above]O2max is observed. To date, RE has been extensively studied among male East African distance runners. By contrast, there is a paucity of data on the RE of female East African runners. A total of 10 female Kenyan runners performed 3 × 1,600-m steady-state run trials on a flat outdoor clay track (400-m lap) at the intensities that corresponded to their everyday training intensities for easy, moderate, and fast running. Running economy together with gait characteristics was determined. Participants showed moderate to very good RE at the first (202 ± 26 ml·kg·km) and second (188 ± 12 ml·kg·km) run trials, respectively. Correlation analysis revealed significant relationship between ground contact time (GCT) and RE at the second run (r = 0.782; p = 0.022), which represented the intensity of anaerobic threshold. This study is the first to report the RE and gait characteristics of East African female athletes measured under everyday training settings. We provided the evidence that GCT is associated with the superior RE of the female Kenyan runners.

  1. Fabrication and characterization of a multidirectional-sensitive contact-enhanced inertial microswitch with a electrophoretic flexible composite fixed electrode

    International Nuclear Information System (INIS)

    Yang, Zhuoqing; Zhu, Bin; Chen, Wenguo; Ding, Guifu; Wang, Hong; Zhao, Xiaolin

    2012-01-01

    A multidirectional-sensitive inertial microswitch with a polymer–metal composite fixed electrode has been designed and fabricated based on surface micromachining in this work. The microswitch mainly consists of a suspended proof mass as a movable electrode and a T-shaped structure on the substrate with maple leaf-like top and cantilevers around the central cylinder as vertical and lateral fixed electrodes. It can sense the applied shock accelerations from any radial direction in the xoy plane and z-axis. The new vertical composite fixed electrode of the switch is completed by electroplating and electrophoretic deposition, which can realize a flexible contact between the electrodes and reduce the bounces and prolong the contact time. As a result, the stability and reliability of the inertial switch could be greatly improved. The fabricated microswitches have been tested and characterized by a standard dropping hammer system. It is shown that the threshold acceleration of the prototype is generally uniform in different sensitive directions in the xoy plane and z-axis, which is about 70 g. The contact time of the microswitch with the composite fixed electrode is ∼110 µs in the vertical direction, which is longer than that (∼65 µs) without a polymer. The test data are in agreement with dynamic finite-element simulation results. (paper)

  2. Role of Metal Contacts in High-Performance Phototransistors Based on WSe 2 Monolayers

    KAUST Repository

    Zhang, Wenjing; Chiu, Ming-Hui; Chen, Chang-Hsiao; Chen, Wei; Li, Lain-Jong; Wee, Andrew Thye Shen

    2014-01-01

    Phototransistors based on monolayer transition metal dichalcogenides (TMD) have high photosensitivity due to their direct band gap transition. However, there is a lack of understanding of the effect of metal contacts on the performance of atomically thin TMD phototransistors. Here, we fabricate phototransistors based on large-area chemical vapor deposition (CVD) tungsten diselenide (WSe2) monolayers contacted with the metals of different work function values. We found that the low Schottky-contact WSe2 phototransistors exhibit a very high photo gain (105) and specific detectivity (1014Jones), values higher than commercial Si- and InGaAs-based photodetectors; however, the response speed is longer than 5 s in ambient air. In contrast, the high Schottky-contact phototransistors display a fast response time shorter than 23 ms, but the photo gain and specific detectivity decrease by several orders of magnitude. Moreover, the fast response speed of the high Schottky-contact devices is maintained for a few months in ambient air. This study demonstrates that the contact plays an important role in TMD phototransistors, and barrier height tuning is critical for optimizing the photoresponse and photoresponsivity. © 2014 American Chemical Society.

  3. Role of Metal Contacts in High-Performance Phototransistors Based on WSe 2 Monolayers

    KAUST Repository

    Zhang, Wenjing

    2014-08-26

    Phototransistors based on monolayer transition metal dichalcogenides (TMD) have high photosensitivity due to their direct band gap transition. However, there is a lack of understanding of the effect of metal contacts on the performance of atomically thin TMD phototransistors. Here, we fabricate phototransistors based on large-area chemical vapor deposition (CVD) tungsten diselenide (WSe2) monolayers contacted with the metals of different work function values. We found that the low Schottky-contact WSe2 phototransistors exhibit a very high photo gain (105) and specific detectivity (1014Jones), values higher than commercial Si- and InGaAs-based photodetectors; however, the response speed is longer than 5 s in ambient air. In contrast, the high Schottky-contact phototransistors display a fast response time shorter than 23 ms, but the photo gain and specific detectivity decrease by several orders of magnitude. Moreover, the fast response speed of the high Schottky-contact devices is maintained for a few months in ambient air. This study demonstrates that the contact plays an important role in TMD phototransistors, and barrier height tuning is critical for optimizing the photoresponse and photoresponsivity. © 2014 American Chemical Society.

  4. Generate tri-directional spectra-compatible time histories using HHT method

    Energy Technology Data Exchange (ETDEWEB)

    Li, Bo; Xie, Wei-Chau, E-mail: xie@uwaterloo.ca; Pandey, Mahesh D.

    2016-11-15

    Highlights: • Hilbert–Huang Transform are applied to modify real earthquake records. • Generate tri-directional time histories compatible with target spectra. • Both GRS and FRS are considered as target spectra. • Target spectra with multiple damping ratios are considered. - Abstract: This paper proposes two algorithms to generate spectrum-compatible time histories based on two approaches recommended by USNRC Standard Review Plan 3.7.1. Hilbert–Huang Transform technique is used to analyze frequency contents and amplitudes of seed motions. Through adjusting the frequency contents and amplitudes of seed motions, spectrum-compatible time histories are obtained. The first algorithm is to generate tri-directional time histories compatible with multi-damping target design spectra (ground response spectra or floor response spectra). The second algorithm is to generate tri-directional time histories compatible with single-damping target design spectra. Examples are presented to demonstrate versatility of these two proposed algorithms to generate spectra-compatible time histories.

  5. Generate tri-directional spectra-compatible time histories using HHT method

    International Nuclear Information System (INIS)

    Li, Bo; Xie, Wei-Chau; Pandey, Mahesh D.

    2016-01-01

    Highlights: • Hilbert–Huang Transform are applied to modify real earthquake records. • Generate tri-directional time histories compatible with target spectra. • Both GRS and FRS are considered as target spectra. • Target spectra with multiple damping ratios are considered. - Abstract: This paper proposes two algorithms to generate spectrum-compatible time histories based on two approaches recommended by USNRC Standard Review Plan 3.7.1. Hilbert–Huang Transform technique is used to analyze frequency contents and amplitudes of seed motions. Through adjusting the frequency contents and amplitudes of seed motions, spectrum-compatible time histories are obtained. The first algorithm is to generate tri-directional time histories compatible with multi-damping target design spectra (ground response spectra or floor response spectra). The second algorithm is to generate tri-directional time histories compatible with single-damping target design spectra. Examples are presented to demonstrate versatility of these two proposed algorithms to generate spectra-compatible time histories.

  6. Contact angle of unset elastomeric impression materials.

    Science.gov (United States)

    Menees, Timothy S; Radhakrishnan, Rashmi; Ramp, Lance C; Burgess, John O; Lawson, Nathaniel C

    2015-10-01

    Some elastomeric impression materials are hydrophobic, and it is often necessary to take definitive impressions of teeth coated with some saliva. New hydrophilic materials have been developed. The purpose of this in vitro study was to compare contact angles of water and saliva on 7 unset elastomeric impression materials at 5 time points from the start of mixing. Two traditional polyvinyl siloxane (PVS) (Aquasil, Take 1), 2 modified PVS (Imprint 4, Panasil), a polyether (Impregum), and 2 hybrid (Identium, EXA'lence) materials were compared. Each material was flattened to 2 mm and a 5 μL drop of distilled water or saliva was dropped on the surface at 25 seconds (t0) after the start of mix. Contact angle measurements were made with a digital microscope at initial contact (t0), t1=2 seconds, t2=5 seconds, t3=50% working time, and t4=95% working time. Data were analyzed with a generalized linear mixed model analysis, and individual 1-way ANOVA and Tukey HSD post hoc tests (α=.05). For water, materials grouped into 3 categories at all time-points: the modified PVS and one hybrid material (Identium) produced the lowest contact angles, the polyether material was intermediate, and the traditional PVS materials and the other hybrid (EXA'lence) produced the highest contact angles. For saliva, Identium, Impregum, and Imprint 4 were in the group with the lowest contact angle at most time points. Modified PVS materials and one of the hybrid materials are more hydrophilic than traditional PVS materials when measured with water. Saliva behaves differently than water in contact angle measurement on unset impression material and produces a lower contact angle on polyether based materials. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  7. Dynamics of the Molten Contact Line

    Science.gov (United States)

    Sonin, Ain A.; Duthaler, Gregg; Liu, Michael; Torresola, Javier; Qiu, Taiqing

    1999-01-01

    The purpose of this program is to develop a basic understanding of how a molten material front spreads over a solid that is below its melting point, arrests, and freezes. Our hope is that the work will contribute toward a scientific knowledge base for certain new applications involving molten droplet deposition, including the "printing" of arbitrary three-dimensional objects by precise deposition of individual molten microdrops that solidify after impact. Little information is available at this time on the capillarity-driven motion and arrest of molten contact line regions. Schiaffino and Sonin investigated the arrest of the contact line of a molten microcrystalline wax spreading over a subcooled solid "target" of the same material. They found that contact line arrest takes place at an apparent liquid contact angle that depends primarily on the Stefan number S=c(T(sub f) -T(sub t)/L based on the temperature difference between the fusion point and the target temperature, and proposed that contact line arrest occurs when the liquid's dynamic contact angle approaches the angle of attack of the solidification front just behind the contact line. They also showed, however, that the conventional continuum equations and boundary conditions have no meaningful solution for this angle. The solidification front angle is determined by the heat flux just behind the contact line, and the heat flux is singular at that point. By comparing experiments with numerical computations, Schiaffino and Sonin estimated that the conventional solidification model must break down within a distance of order 0.1 - 1 microns of the contact line. The physical mechanism for this breakdown is as yet undetermined, and no first-principles theory exists for the contact angle at arrest. Schiaffino and Sonin also presented a framework for understanding how to moderate Weber number molten droplet deposition in terms of similarity laws and experimentation. The study is based on experiments with three molten

  8. Stokes flow inside an evaporating liquid line for any contact angle

    Science.gov (United States)

    Petsi, A. J.; Burganos, V. N.

    2008-09-01

    Evaporation of droplets or liquid films lying on a substrate induces internal viscous flow, which affects the transport of suspended particles and, thus, the final deposit profile in numerous applications. In this work, the problem of Stokes flow inside a two-dimensional droplet, representing the cross section of an evaporating liquid line lying on a flat surface, is considered. The stream function formulation is adopted, leading to the biharmonic equation in bipolar coordinates. A solution in closed form is obtained for any contact angle in (0,π) and is, thus, valid for both hydrophilic and hydrophobic substrates. The solution can be used with any type of evaporation mechanism, including diffusion, convection, or kinetically controlled modes. Both pinned and depinned contact lines are considered. For the boundary conditions to be compatible at the contact lines, the Navier slip boundary condition is applied on the substrate. Numerical results are presented for kinetically and diffusion controlled evaporation. For pinned contact lines, the flow inside the evaporating liquid line is directed towards the edges, thus, promoting the coffee stain phenomenon. In the case of depinned contact lines and contact angle less than π/2 , the flow is directed towards the center of the droplet, whereas, for strongly hydrophobic substrates it is directed outwards.

  9. On contact modelling in isogeometric analysis

    Science.gov (United States)

    Cardoso, R. P. R.; Adetoro, O. B.

    2017-11-01

    IsoGeometric Analysis (IGA) has proved to be a reliable numerical tool for the simulation of structural behaviour and fluid mechanics. The main reasons for this popularity are essentially due to: (i) the possibility of using higher order polynomials for the basis functions; (ii) the high convergence rates possible to achieve; (iii) the possibility to operate directly on CAD geometry without the need to resort to a mesh of elements. The major drawback of IGA is the non-interpolatory characteristic of the basis functions, which adds a difficulty in handling essential boundary conditions and makes it particularly challenging for contact analysis. In this work, the IGA is expanded to include frictionless contact procedures for sheet metal forming analyses. Non-Uniform Rational B-Splines (NURBS) are going to be used for the modelling of rigid tools as well as for the modelling of the deformable blank sheet. The contact methods developed are based on a two-step contact search scheme, where during the first step a global search algorithm is used for the allocation of contact knots into potential contact faces and a second (local) contact search scheme where point inversion techniques are used for the calculation of the contact penetration gap. For completeness, elastoplastic procedures are also included for a proper description of the entire IGA of sheet metal forming processes.

  10. Real-time nondestructive monitoring of the gas tungsten arc welding (GTAW) process by combined airborne acoustic emission and non-contact ultrasonics

    Science.gov (United States)

    Zhang, Lu; Basantes-Defaz, Alexandra-Del-Carmen; Abbasi, Zeynab; Yuhas, Donald; Ozevin, Didem; Indacochea, Ernesto

    2018-03-01

    Welding is a key manufacturing process for many industries and may introduce defects into the welded parts causing significant negative impacts, potentially ruining high-cost pieces. Therefore, a real-time process monitoring method is important to implement for avoiding producing a low-quality weld. Due to high surface temperature and possible contamination of surface by contact transducers, the welding process should be monitored via non-contact transducers. In this paper, airborne acoustic emission (AE) transducers tuned at 60 kHz and non-contact ultrasonic testing (UT) transducers tuned at 500 kHz are implemented for real time weld monitoring. AE is a passive nondestructive evaluation method that listens for the process noise, and provides information about the uniformity of manufacturing process. UT provides more quantitative information about weld defects. One of the most common weld defects as burn-through is investigated. The influences of weld defects on AE signatures (time-driven data) and UT signals (received signal energy, change in peak frequency) are presented. The level of burn-through damage is defined by using single method or combine AE/UT methods.

  11. The Josephson effect in atomic contacts; Effect Josephson dans les contacts atomiques

    Energy Technology Data Exchange (ETDEWEB)

    Chauvin, M

    2005-11-15

    The Josephson effect appears when a weak-link establishes phase coherence between two superconductors. A unifying theory of this effect emerged in the 90's within the framework of mesoscopic physics. Based on two cornerstone concepts, conduction channels and Andreev reflection, it predicts the current-phase relation for the most basic weak-link: a single conduction channel of arbitrary transmission. This thesis illustrates this mesoscopic point of view with experiments on superconducting atomic size contacts. In particular, we have focused on the supercurrent peak around zero voltage, put into evidence the ac Josephson currents in a contact under constant bias voltage (Shapiro resonances and photon assisted multiple Andreev reflections), and performed direct measurements of the current-phase relation. (author)

  12. PATTERNS OF CONTACT AND INVOLVEMENT BETWEEN ADOLESCENTS AND THEIR NON-RESIDENT FATHERS

    Directory of Open Access Journals (Sweden)

    De Wit, Estelle

    2014-04-01

    Full Text Available This study examined the patterns of contact and involvement between adolescents and their non-resident fathers after divorce. The data were analysed to determine the role of Lamb, Pleck and Levine’s (1986 three constructs in the involvement of non-resident fathers, i.e. interaction, availability and responsibility. The results indicated that the majority of male and female adolescents reported continued direct and indirect contact with their fathers, regardless of paternal remarriage and the lapse of time since the divorce. Boys reported higher levels of communication and feelings of emotional closeness than girls. Overall, the study postulates that non-resident fathers play a less significant role in providing parental guidance to their children.

  13. Electro-thermal analysis of contact resistance

    Science.gov (United States)

    Pandey, Nitin; Jain, Ishant; Reddy, Sudhakar; Gulhane, Nitin P.

    2018-05-01

    Electro-Mechanical characterization over copper samples are performed at the macroscopic level to understand the dependence of electrical contact resistance and temperature on surface roughness and contact pressure. For two different surface roughness levels of samples, six levels of load are selected and varied to capture the bulk temperature rise and electrical contact resistance. Accordingly, the copper samples are modelled and analysed using COMSOLTM as a simulation package and the results are validated by the experiments. The interface temperature during simulation is obtained using Mikic-Elastic correlation and by directly entering experimental contact resistance value. The load values are varied and then reversed in a similar fashion to capture the hysteresis losses. The governing equations & assumptions underlying these models and their significance are examined & possible justification for the observed variations are discussed. Equivalent Greenwood model is also predicted by mapping the results of the experiment.

  14. Observer-Based Perturbation Extremum Seeking Control with Input Constraints for Direct-Contact Membrane Distillation Process

    KAUST Repository

    Eleiwi, Fadi

    2017-05-08

    An Observer-based Perturbation Extremum Seeking Control (PESC) is proposed for a Direct-Contact Membrane Distillation (DCMD) process. The process is described with a dynamic model that is based on a 2D Advection-Diffusion Equation (ADE) model which has pump flow rates as process inputs. The objective of the controller is to optimize the trade-off between the permeate mass flux and the energy consumption by the pumps inside the process. Cases of single and multiple control inputs are considered through the use of only the feed pump flow rate or both the feed and the permeate pump flow rates. A nonlinear Lyapunov-based observer is designed to provide an estimation for the temperature distribution all over the designated domain of the DCMD process. Moreover, control inputs are constrained with an anti-windup technique to be within feasible and physical ranges. Performance of the proposed structure is analyzed, and simulations based on real DCMD process parameters for each control input are provided.

  15. Observer-based perturbation extremum seeking control with input constraints for direct-contact membrane distillation process

    Science.gov (United States)

    Eleiwi, Fadi; Laleg-Kirati, Taous Meriem

    2018-06-01

    An observer-based perturbation extremum seeking control is proposed for a direct-contact membrane distillation (DCMD) process. The process is described with a dynamic model that is based on a 2D advection-diffusion equation model which has pump flow rates as process inputs. The objective of the controller is to optimise the trade-off between the permeate mass flux and the energy consumption by the pumps inside the process. Cases of single and multiple control inputs are considered through the use of only the feed pump flow rate or both the feed and the permeate pump flow rates. A nonlinear Lyapunov-based observer is designed to provide an estimation for the temperature distribution all over the designated domain of the DCMD process. Moreover, control inputs are constrained with an anti-windup technique to be within feasible and physical ranges. Performance of the proposed structure is analysed, and simulations based on real DCMD process parameters for each control input are provided.

  16. Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

    Science.gov (United States)

    Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed

    2014-01-01

    Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability.

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... to the journals may be interrupted during this time. We are working to resolve the issue quickly ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ...

  18. Human exposure to trace elements through the skin by direct contact with clothing: Risk assessment

    International Nuclear Information System (INIS)

    Rovira, Joaquim; Nadal, Martí; Schuhmacher, Marta; Domingo, José L.

    2015-01-01

    Metals in textile products and clothing are used for many purposes, such as metal complex dyes, pigments, mordant, catalyst in synthetic fabrics manufacture, synergists of flame retardants, antimicrobials, or as water repellents and odour-preventive agents. When present in textile materials, heavy metals may mean a potential danger to human health. In the present study, the concentrations of a number of elements (Al, As, B, Ba, Be, Bi, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mn, Mo, Ni, Pb, Sb, Sc, Se, Sm, Sn, Sr, Tl, V, and Zn) were determined in skin-contact clothes. Analysed clothes were made of different materials, colours, and brands. Interestingly, we found high levels of Cr in polyamide dark clothes (605 mg/kg), high Sb concentrations in polyester clothes (141 mg/kg), and great Cu levels in some green cotton fabrics (around 280 mg/kg). Dermal contact exposure and human health risks for adult males, adult females, and for <1-year-old children were assessed. Non-carcinogenic and carcinogenic risks were below safe (HQ<1) and acceptable (<10 −6 ) limits, respectively, according to international standards. However, for Sb, non-carcinogenic risk was above 10% of the safety limit (HQ>0.1) for dermal contact with clothes. - Highlights: • We determined in skin-contact clothes the concentrations of a number of metals. • Dermal contact exposure and health risks for adults and for 1-year-old children were assessed. • Carcinogenic risks were considered as acceptable (<10 −6 ). • For non-carcinogenic risks, only Sb exceeded a 10% of the HQ for dermal contact with clothes

  19. Contact-dependent cytopathogenic mechanisms of Trichomonas vaginalis

    Energy Technology Data Exchange (ETDEWEB)

    Krieger, J.N.; Ravdin, J.I.; Rein, M.F.

    1985-12-01

    The cytopathogenic mechanisms of Trichomonas vaginalis have been debated since the 1940s. We examined the following three proposed pathogenic mechanisms: contact-dependent extracellular killing, cytophagocytosis, and extracellular cytotoxins. Serial observations of Chinese hamster ovary (CHO) cell monolayers exposed to trichomonads revealed that (i) trichomonads form clumps, (ii) the clumps adhere to cells in culture, and (iii) monolayer destruction occurs only in areas of contact with T. vaginalis. Kinetic analysis of target cell killing by trichomonads revealed that the probability of CHO cell death was related to the probability of contact with T. vaginalis, supporting the observation by microscopy that trichomonads kill cells only by direct contact. Simultaneous studies of /sup 111/indium oxine label release from CHO cells and trypan blue dye exclusion demonstrated that T. vaginalis kills target cells without phagocytosis. Filtrates of trichomonad cultures or from media in which trichomonads were killing CHO cells had no effect on CHO cell monolayers, indicating that trichomonads do not kill cells by a cell-free or secreted cytotoxin. The microfilament inhibitor cytochalasin D (10 micrograms/ml) inhibited trichomonad killing of CHO cell monolayers by 80% (P less than 0.0001). In contrast, the microtubule inhibitor vinblastine (10(-6) M) caused only 17% inhibition of trichomonad destruction of CHO cell monolayers (P less than 0.020), whereas colchicine (10(-6) M) had no effect. T. vaginalis kills target cells by direct contact without phagocytosis. This event requires intact trichomonad microfilament function; microtubule function appears not to be essential.

  20. Contact-dependent cytopathogenic mechanisms of Trichomonas vaginalis

    International Nuclear Information System (INIS)

    Krieger, J.N.; Ravdin, J.I.; Rein, M.F.

    1985-01-01

    The cytopathogenic mechanisms of Trichomonas vaginalis have been debated since the 1940s. We examined the following three proposed pathogenic mechanisms: contact-dependent extracellular killing, cytophagocytosis, and extracellular cytotoxins. Serial observations of Chinese hamster ovary (CHO) cell monolayers exposed to trichomonads revealed that (i) trichomonads form clumps, (ii) the clumps adhere to cells in culture, and (iii) monolayer destruction occurs only in areas of contact with T. vaginalis. Kinetic analysis of target cell killing by trichomonads revealed that the probability of CHO cell death was related to the probability of contact with T. vaginalis, supporting the observation by microscopy that trichomonads kill cells only by direct contact. Simultaneous studies of 111 indium oxine label release from CHO cells and trypan blue dye exclusion demonstrated that T. vaginalis kills target cells without phagocytosis. Filtrates of trichomonad cultures or from media in which trichomonads were killing CHO cells had no effect on CHO cell monolayers, indicating that trichomonads do not kill cells by a cell-free or secreted cytotoxin. The microfilament inhibitor cytochalasin D (10 micrograms/ml) inhibited trichomonad killing of CHO cell monolayers by 80% (P less than 0.0001). In contrast, the microtubule inhibitor vinblastine (10(-6) M) caused only 17% inhibition of trichomonad destruction of CHO cell monolayers (P less than 0.020), whereas colchicine (10(-6) M) had no effect. T. vaginalis kills target cells by direct contact without phagocytosis. This event requires intact trichomonad microfilament function; microtubule function appears not to be essential

  1. Enhancement to Non-Contacting Stress Measurement of Blade Vibration Frequency

    Science.gov (United States)

    Platt, Michael; Jagodnik, John

    2011-01-01

    A system for turbo machinery blade vibration has been developed that combines time-of-arrival sensors for blade vibration amplitude measurement and radar sensors for vibration frequency and mode identification. The enabling technology for this continuous blade monitoring system is the radar sensor, which provides a continuous time series of blade displacement over a portion of a revolution. This allows the data reduction algorithms to directly calculate the blade vibration frequency and to correctly identify the active modes of vibration. The work in this project represents a significant enhancement in the mode identification and stress calculation accuracy in non-contacting stress measurement system (NSMS) technology when compared to time-of-arrival measurements alone.

  2. In reactor measurements, modeling and assessments to predict liquid injection shutdown system nozzle to Calandria tube time to contact

    International Nuclear Information System (INIS)

    Kirstein, K.; Kalenchuk, D.

    2011-01-01

    Over the past few years there has been an expanding effort to assess the potential for Calandria Tubes (CTs) coming into contact with Liquid Injection Shutdown System (LISS) Nozzles to ensure continued contact-free operation as required by CSA N285.4. LISS Nozzles (LINs), which run perpendicular to and between rows of fuel channels, sag at a slower rate than the fuel channels. As a result certain LINs may come in contact with CTs above them. The CT/LIN gaps can be predicted from calculated CT sag, LIN sag and a number of component and installation tolerances. This method however results in very conservative predictions when compared to measurements, confirmed with the in reactor measurements initiated in 2000, when gaps were successfully measured the first time using images obtained from a camera-assisted measurement tool inserted into the calandria. To reduce the conservatism of the CT/LIN gap predictions, statistical CT/LIN gap models are used instead. They are derived from a comparison between calculated gaps based on nominal dimensions and the visual image based measured gaps. These reactor specific (typically 95% confidence level) CT/LIN gap models account for all uncertainties and deviations from nominal values. Prediction error margins reduce as more in-reactor gap measurements become available. Each year more measurements are being made using this standardized visual CT/LIN proximity method. The subsequently prepared reactor-specific models have been used to provide time to contact for every channel above the LINs at these stations. In a number of cases it has been used to demonstrate that the reactor can be operated to its end of life before refurbishment with no predicted contact, or specific at-risk channels have been identified for which appropriate remedial actions could be implemented in a planned manner. (author)

  3. A novel in-vitro method for assessing contact lens surface dewetting: Non-invasive keratograph dry-up time (NIK-DUT).

    Science.gov (United States)

    Marx, Sebastian; Sickenberger, Wolfgang

    2017-12-01

    This study was designed to develop a novel technique called non-invasive keratograph dry-up time (NIK-DUT), which used an adapted corneal topographer, to analyse in-vitro contact lens surface dewetting and the effects of combinations of lenses and lens care solutions on dewetting. Variables were assessed to optimise sensitivity and reproducibility. To validate the method, in-vitro dewetting of silicone hydrogel contact lenses (balafilcon A, comfilcon A, lotrafilcon A, lotrafilcon B and senofilcon A) was tested. All lens types were soaked in OPTI-FREE ® PureMoist ® Multipurpose Disinfecting Solution (OFPM) and Sensitive Eyes ® Saline Solution. The mean NIK-DUT, defined as drying of 25% of the placido ring measurement segments (NIK-DUT_S25), was calculated for each lens/lens solution combination and a visual map constructed representing the time and location of the dry-up event. Optimal conditions for NIK-DUT measurement included mounting onto a glass stage with a surface geometry of r=8.5mm, e=0, and measuring with high intensity red or white illumination. This method detected significant differences in contact lens dewetting with different lens soaking solutions. NIK-DUT_S25 for all lenses was longer when pre-soaked in OFPM versus saline. Visual analysis showed that dewetting of contact lenses was not uniform across surfaces and differed between test solutions. NIK-DUT is suitable for detecting differences in dewetting among various contact lenses and lens-care combinations. NIK-DUT can quantify the dewetting of large areas of lens surfaces with little subjective influence. Lens care solutions containing surface-active wetting agents were found to delay surface dewetting of silicone hydrogel lenses. Copyright © 2017. Published by Elsevier Ltd.

  4. Experimental and numerical study of waste heat recovery characteristics of direct contact thermoelectric generator

    International Nuclear Information System (INIS)

    Kim, Tae Young; Negash, Assmelash; Cho, Gyubaek

    2017-01-01

    Highlights: • Energy harvesting performance of direct contact thermoelectric generator was studied. • Power-current and voltage-current curves were given for various operating conditions. • Output power prediction using numerical results and empirical correlation was verified. • A 1.0–2.0% conversion efficiency and 5.7–11.1% heat recovery efficiency were obtained. • A 0.25% increase in efficiency was found with a 10 K decrease in coolant temperature. - Abstract: In this study, waste heat recovery performance of a direct contact thermoelectric generator (DCTEG) is experimentally investigated on a diesel engine. In order to conduct an insightful analysis of the DCTEG characteristics, three experimental parameters—engine load, rotation speed, and coolant temperature—are chosen to vary over ranges during the experiments. Experimental results show that higher temperature differences across thermoelectric modules (TEM), larger engine loads, and rotation speeds lead to an improved energy conversion efficiency of the DCTEG, which lies in the range of approximately 1.0–2.0%, while the output power ranges approximately 12–45 W. The increase in the conversion efficiency for an increased engine load becomes more noticeable with a higher engine rotation speed. A 10 K decrease in the coolant temperature yields an approximately 0.25% increase in the conversion efficiency for the engine operating conditions tested. In addition, 3D numerical simulations were conducted to investigate the heat transfer and pressure characteristics of the DCTEG. Numerically obtained exhaust gas temperatures exiting the DCTEG were in good agreement with experimental results. It is also revealed that incorporation of the temperature fields from the numerical simulation and an empirical correlation for a temperature-power relationship provides a good predictor for output power from the DCTEG, especially at low engine load conditions, which deviates from experimental results as the

  5. [Eye contact effects: A therapeutic issue?

    Science.gov (United States)

    Baltazar, M; Conty, L

    2016-12-01

    The perception of a direct gaze - that is, of another individual's gaze directed at the observer that leads to eye contact - is known to influence a wide range of cognitive processes and behaviors. We stress that these effects mainly reflect positive impacts on human cognition and may thus be used as relevant tools for therapeutic purposes. In this review, we aim (1) to provide an exhaustive review of eye contact effects while discussing the limits of the dominant models used to explain these effects, (2) to illustrate the therapeutic potential of eye contact by targeting those pathologies that show both preserved gaze processing and deficits in one or several functions that are targeted by the eye contact effects, and (3) to propose concrete ways in which eye contact could be employed as a therapeutic tool. (1) We regroup the variety of eye contact effects into four categories, including memory effects, activation of prosocial behavior, positive appraisals of self and others and the enhancement of self-awareness. We emphasize that the models proposed to account for these effects have a poor predictive value and that further descriptions of these effects is needed. (2) We then emphasize that people with pathologies that affect memory, social behavior, and self and/or other appraisal, and self-awareness could benefit from eye contact effects. We focus on depression, autism and Alzheimer's disease to illustrate our proposal. To our knowledge, no anomaly of eye contact has been reported in depression. Patients suffering from Alzheimer disease, at the early and moderate stage, have been shown to maintain a normal amount of eye contact with their interlocutor. We take into account that autism is controversial regarding whether gaze processing is preserved or altered. In the first view, individuals are thought to elude or omit gazing at another's eyes while in the second, individuals are considered to not be able to process the gaze of others. We adopt the first stance

  6. Primary cilia utilize glycoprotein-dependent adhesion mechanisms to stabilize long-lasting cilia-cilia contacts

    Directory of Open Access Journals (Sweden)

    Ott Carolyn

    2012-04-01

    Full Text Available Abstract Background The central tenet of cilia function is sensing and transmitting information. The capacity to directly contact extracellular surfaces would empower primary cilia to probe the environment for information about the nature and location of nearby surfaces. It has been well established that flagella and other motile cilia perform diverse cellular functions through adhesion. We hypothesized that mammalian primary cilia also interact with the extracellular environment through direct physical contact. Methods We identified cilia in rod photoreceptors and cholangiocytes in fixed mouse tissues and examined the structures that these cilia contact in vivo. We then utilized an MDCK cell culture model to characterize the nature of the contacts we observed. Results In retina and liver tissue, we observed that cilia from nearby cells touch one another. Using MDCK cells, we found compelling evidence that these contacts are stable adhesions that form bridges between two cells, or networks between many cells. We examined the nature and duration of the cilia-cilia contacts and discovered primary cilia movements that facilitate cilia-cilia encounters. Stable adhesions form as the area of contact expands from a single point to a stretch of tightly bound, adjacent cilia membranes. The cilia-cilia contacts persisted for hours and were resistant to several harsh treatments such as proteases and DTT. Unlike many other cell adhesion mechanisms, calcium was not required for the formation or maintenance of cilia adhesion. However, swainsonine, which blocks maturation of N-linked glycoproteins, reduced contact formation. We propose that cellular control of adhesion maintenance is active because cilia adhesion did not prevent cell division; rather, contacts dissolved during mitosis as cilia were resorbed. Conclusions The demonstration that mammalian primary cilia formed prolonged, direct, physical contacts supports a novel paradigm: that mammalian primary

  7. A fluorescence-based method for direct measurement of submicrosecond intramolecular contact formation in biopolymers: an exploratory study with polypeptides.

    Science.gov (United States)

    Hudgins, Robert R; Huang, Fang; Gramlich, Gabriela; Nau, Werner M

    2002-01-30

    A fluorescent amino acid derivative (Fmoc-DBO) has been synthesized, which contains 2,3-diazabicyclo[2.2.2]oct-2-ene (DBO) as a small, hydrophilic fluorophore with an extremely long fluorescence lifetime (325 ns in H2O and 505 ns in D2O under air). Polypeptides containing both the DBO residue and an efficient fluorescence quencher allow the measurement of rate constants for intramolecular end-to-end contact formation. Bimolecular quenching experiments indicated that Trp, Cys, Met, and Tyr are efficient quenchers of DBO (k(q) = 20, 5.1, 4.5, and 3.6 x 10(8) M(-1) x s(-1) in D2O), while the other amino acids are inefficient. The quenching by Trp, which was selected as an intrinsic quencher, is presumed to involve exciplex-induced deactivation. Flexible, structureless polypeptides, Trp-(Gly-Ser)n-DBO-NH2, were prepared by standard solid-phase synthesis, and the rates of contact formation were measured through the intramolecular fluorescence quenching of DBO by Trp with time-correlated single-photon counting, laser flash photolysis, and steady-state fluorometry. Rate constants of 4.1, 6.8, 4.9, 3.1, 2.0, and 1.1 x 10(7) s(-1) for n = 0, 1, 2, 4, 6, and 10 were obtained. Noteworthy was the relatively slow quenching for the shortest peptide (n = 0). The kinetic data are in agreement with recent transient absorption studies of triplet probes for related peptides, but the rate constants are significantly larger. In contrast to the flexible structureless Gly-Ser polypeptides, the polyproline Trp-Pro4-DBO-NH2 showed insignificant fluorescence quenching, suggesting that a high polypeptide flexibility and the possibility of probe-quencher contact is essential to induce quenching. Advantages of the new fluorescence-based method for measuring contact formation rates in biopolymers include high accuracy, fast time range (100 ps-1 micros), and the possibility to perform measurements in water under air.

  8. Longitudinal intergroup contact effects on prejudice using self- and observer-reports.

    Science.gov (United States)

    Dhont, Kristof; Van Hiel, Alain; De Bolle, Marleen; Roets, Arne

    2012-06-01

    Longitudinal effects of intergroup contact on prejudice were investigated in a sample of 65 young adults (Sample 1) and a sample of their close friends (Sample 2, N= 172), adopting a full cross-lagged panel design. We first validated the self-report measure of intergroup contact from Sample 1 with observer ratings from Sample 2 by demonstrating that self-reports and observer ratings of contact were highly correlated. Moreover, we obtained significant cross-lagged effects of intergroup contact on prejudice with both contact measures, thereby providing a second validation for the use of self-reports of intergroup contact. Finally, by the use of latent change modelling, we demonstrated that, although no overall significant change in contact and prejudice over time was found, there was meaningful variation in absolute change in the individual levels of intergroup contact and prejudice. In particular, some individuals showed increases while others showed decreases in contact or prejudice across time. Moreover, higher levels of intergroup contact at Time 1 were followed by larger subsequent decreases in prejudice between Time 1 and Time 2, and changes in contact were significantly and negatively related to changes in prejudice. Methodological implications of the findings are discussed. © 2012 The British Psychological Society.

  9. Human exposure to trace elements through the skin by direct contact with clothing: Risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Rovira, Joaquim [Laboratory of Toxicology and Environmental Health, School of Medicine, IISPV, Universitat Rovira i Virgili, Sant Llorenç 21, 43201 Reus, Catalonia (Spain); Environmental Engineering Laboratory, Departament d' Enginyeria Quimica, Universitat Rovira i Virgili, Av. Països Catalans 26, 43007 Tarragona, Catalonia (Spain); Nadal, Martí [Laboratory of Toxicology and Environmental Health, School of Medicine, IISPV, Universitat Rovira i Virgili, Sant Llorenç 21, 43201 Reus, Catalonia (Spain); Schuhmacher, Marta [Laboratory of Toxicology and Environmental Health, School of Medicine, IISPV, Universitat Rovira i Virgili, Sant Llorenç 21, 43201 Reus, Catalonia (Spain); Environmental Engineering Laboratory, Departament d' Enginyeria Quimica, Universitat Rovira i Virgili, Av. Països Catalans 26, 43007 Tarragona, Catalonia (Spain); Domingo, José L., E-mail: joseluis.domingo@urv.cat [Laboratory of Toxicology and Environmental Health, School of Medicine, IISPV, Universitat Rovira i Virgili, Sant Llorenç 21, 43201 Reus, Catalonia (Spain)

    2015-07-15

    Metals in textile products and clothing are used for many purposes, such as metal complex dyes, pigments, mordant, catalyst in synthetic fabrics manufacture, synergists of flame retardants, antimicrobials, or as water repellents and odour-preventive agents. When present in textile materials, heavy metals may mean a potential danger to human health. In the present study, the concentrations of a number of elements (Al, As, B, Ba, Be, Bi, Cd, Co, Cr, Cu, Fe, Hg, Mg, Mn, Mo, Ni, Pb, Sb, Sc, Se, Sm, Sn, Sr, Tl, V, and Zn) were determined in skin-contact clothes. Analysed clothes were made of different materials, colours, and brands. Interestingly, we found high levels of Cr in polyamide dark clothes (605 mg/kg), high Sb concentrations in polyester clothes (141 mg/kg), and great Cu levels in some green cotton fabrics (around 280 mg/kg). Dermal contact exposure and human health risks for adult males, adult females, and for <1-year-old children were assessed. Non-carcinogenic and carcinogenic risks were below safe (HQ<1) and acceptable (<10{sup −6}) limits, respectively, according to international standards. However, for Sb, non-carcinogenic risk was above 10% of the safety limit (HQ>0.1) for dermal contact with clothes. - Highlights: • We determined in skin-contact clothes the concentrations of a number of metals. • Dermal contact exposure and health risks for adults and for 1-year-old children were assessed. • Carcinogenic risks were considered as acceptable (<10{sup −6}). • For non-carcinogenic risks, only Sb exceeded a 10% of the HQ for dermal contact with clothes.

  10. Preparation of novel poly(vinylidene fluoride)/TiO2 photocatalysis membranes for use in direct contact membrane distillation

    Science.gov (United States)

    Li, Yukun; Dong, Shuying; Zhu, Liang

    2018-03-01

    Immobilization of TiO2 is a potential approach to obtain photocatalytic membranes that could eliminate concentration polarization in sewage disposal for direct contact membrane distillation (DCMD) process. A simple non-solvent-induced phase separation (NIPS) method was proposed to prepare poly(vinylidene fluoride) (PVDF) membrane, and the double-coating technology was further used to prepare the self-cleaning membranes with different TiO2 content. The effects of TiO2 nano-particles on membrane crystal form, morphology, porosity, pore size, pore size distribution, hydrophobicity, permeation, and photocatalytic efficiency were investigated, respectively. The flux of the prepared membranes is higher than the membrane (MS) provided by Membrane Solutions, LLC, in DCMD process. The contact angle between water and membrane could be increased 22° by introducing photocatalytic layer containing TiO2. During the photocatalytic test, 65.78-96.31% degrading rate of 15 mg/L Rhodamine B (RhB) was achieved. The relative flux of the membrane T-3 can be recovered to 0.96 in photocatalysis-membrane reactor for 8 h UV radiation. The fabricated membrane has great potential in high-salty dyeing wastewater treatment due to its high hydrophobicity and photocatalytic capability. [Figure not available: see fulltext.

  11. Sorption of uranyl ions on silica. Effects of contact time, pH, ionic strength, concentration and phosphate

    International Nuclear Information System (INIS)

    Zhang Hongxia; Tao Zuyi

    2002-01-01

    The sorption of UO 2 2+ and phosphate on silica were simultaneously studied. The effect of contact time between the solid phase and aqueous solution, pH and ionic strength on the UO 2 2+ sorption in the absence and the presence of phosphate was investigated. The effect of contact time between the solid phase and aqueous solution, pH and ionic strength on the phosphate sorption was investigated too. The isotherms of UO 2 2+ and phosphate sorption at different pH values were determined. It was found that as compared with the sorption in the absence of phosphate, the sorption of UO 2 2+ on silica in the presence of phosphate is increased at low pH and decreased at high pH; the abruptly increased with increasing pH in the pH range 3-6; the sorption is gradually decreased with increasing pH in the pH range 2-12; the sorption insensitive and the sorption of phosphate is sensitive to ionic strength. (author)

  12. Enhanced visible light activity on direct contact Z-scheme g-C{sub 3}N{sub 4}-TiO{sub 2} photocatalyst

    Energy Technology Data Exchange (ETDEWEB)

    Li, Juan [National & Local Joint Engineering Research Center for Applied Technology of Hybrid Nanomaterials, Henan University, Kaifeng, 475004 (China); Collaborative Innovation Center of Nano Functional Materials and Applications of Henan Province, Henan University, Kaifeng, 475004 (China); College of Chemistry and Chemical Engineering, Henan University, Kaifeng, 475004 (China); Zhang, Min [National & Local Joint Engineering Research Center for Applied Technology of Hybrid Nanomaterials, Henan University, Kaifeng, 475004 (China); Collaborative Innovation Center of Nano Functional Materials and Applications of Henan Province, Henan University, Kaifeng, 475004 (China); Li, Qiuye, E-mail: qiuyeli@henu.edu.cn [National & Local Joint Engineering Research Center for Applied Technology of Hybrid Nanomaterials, Henan University, Kaifeng, 475004 (China); Collaborative Innovation Center of Nano Functional Materials and Applications of Henan Province, Henan University, Kaifeng, 475004 (China); Yang, Jianjun, E-mail: yangjianjun@henu.edu.cn [National & Local Joint Engineering Research Center for Applied Technology of Hybrid Nanomaterials, Henan University, Kaifeng, 475004 (China); Collaborative Innovation Center of Nano Functional Materials and Applications of Henan Province, Henan University, Kaifeng, 475004 (China)

    2017-01-01

    Highlights: • The g-C{sub 3}N{sub 4}-TiO{sub 2} composites were obtained by simple solid state sintering. • The composites were direct contact Z-scheme without an electron mediator. • TiO{sub 2} with large amount of SETOV was obtained by dehydration of NTA. - Abstract: Direct contact Z-scheme g-C{sub 3}N{sub 4}-TiO{sub 2} nanocomposites without an electron mediator are prepared via simple annealing the mixture of bulk g-C{sub 3}N{sub 4} and nanotube titanic acid (NTA) in air at 600 °C for 2 h. In the process of annealing, the bulk g-C{sub 3}N{sub 4} transformed to ultra-thin g-C{sub 3}N{sub 4} nanosheets, and NTA converted to a novel anatase TiO{sub 2}, then the two components formed a close interaction. The XPS result reveals that some amount of nitrogen is doped into this novel-TiO{sub 2}, and g-C{sub 3}N{sub 4} nanosheets exist in the composites. The results of XRD, TEM and TG indicate that the thickness of g-C{sub 3}N{sub 4} nanosheets is very thin. The ESR spectrum shows the existence of Ti{sup 3+} and single-electron-trapped oxygen vacancy in the 30%g-C{sub 3}N{sub 4}-TiO{sub 2} composites. In photocatalytic activity test, the 30%g-C{sub 3}N{sub 4}-TiO{sub 2} nanocomposites showed an excellent photo-oxidation activity of propylene under visible light irradiation (λ≥ 420 nm), and the removal efficiency of propylene reached as high as 56.6%, and the activity kept nearly 82% after four consecutive recycles. Photoluminescence (PL) result using terephthalic acid (TA) as a probe molecule indicated that the g-C{sub 3}N{sub 4}-TiO{sub 2} nanocomposites displayed a Z-sheme photocatalytic reaction system and this should be the main reason for the high photocatalytic activity. A possible photocatalytic mechanism was proposed on the basis of PL result and transient photocurrent-time curves.

  13. Occupational contact urticaria and protein contact dermatitis.

    Science.gov (United States)

    Doutre, Marie-Sylvie

    2005-01-01

    Irritant dermatitis and eczema are the most prevalent occupational skin diseases. Less common are immediate contact reactions such as contact urticaria and protein contact dermatitis. Occupational contact urticaria can be subdivided into two categories, immunological and non immunological. However, some agents can induce these two types of reactions. Contact urticaria to natural rubber latex is particularly frequent among health care personnel, but contact urticaria to a wide variety of other substances occurs in many other occupations. Among those at risk are cooks, bakers, butchers, restaurant personnel, veterinarians, hairdressers, florists, gardeners, and forestry workers. Protein contact dermatitis in some of these occupations is caused principally by proteins of animal or plant origin, especially among individuals with a history of atopic dermatitis. Diagnosis requires careful interrogation, clinical examination and skin tests (open tests and prick tests with immediate lecture) to identify a particular contact allergen.

  14. Design, simulation and fabrication of a novel contact-enhanced MEMS inertial switch with a movable contact point

    International Nuclear Information System (INIS)

    Cai Haogang; Ding Guifu; Yang Zhuoqing; Su Zhijuan; Zhou Jiansheng; Wang Hong

    2008-01-01

    A novel inertial switch based on a micro-electro-mechanical system (MEMS) was designed, which consists of three main parts: a proof mass as the movable electrode, a cross beam as the stationary electrode and a movable contact point to prolong the contact time. A MATLAB/Simulink model, which had been verified by comparison with ANSYS transient simulation, was built to simulate the dynamic response, based on which the contact-enhancing mechanism was confirmed and the dependence of threshold acceleration on the proof mass thickness was studied. The simulated dynamic responses under various accelerations exhibit satisfactory device behaviors: the switch-on time is prolonged under transient acceleration; the switch-on state is more continuous than the conventional design under long lasting acceleration. The inertial micro-switch was fabricated by multilayer electroplating technology and then tested by a drop hammer experiment. The test results indicate that the contact effect was improved significantly and a steady switch-on time of over 50 µs was observed under half-sine wave acceleration with 1 ms duration, in agreement with the dynamic simulation

  15. Establishing an upper bound on contact resistivity of ohmic contacts to n-GaN nanowires

    International Nuclear Information System (INIS)

    Blanchard, Paul; Bertness, Kris A; Harvey, Todd; Sanford, Norman

    2014-01-01

    Contact resistivity ρ c is an important figure of merit in evaluating and improving the performance of electronic and optoelectronic devices. Due to the small size, unique morphology, and uncertain transport properties of semiconductor nanowires (NWs), measuring ρ c of contacts to NWs can be particularly challenging. In this work, Si-doped n-GaN NWs were grown by molecular beam epitaxy. Four-contact structures with 20 nm Ti/200 nm Al contacts were fabricated on individual NWs by photolithography, and the contacts were annealed to achieve ohmic behavior. Two-point resistances R 23  and four-point collinear resistances R 23collinear  were measured between the middle two contacts on each NW. These resistances were then modeled by taking into account the non-uniform distribution of current flow along the length of each contact. Contrary to the assumption that the resistance difference R 23 −R 23collinear  is equal to the total contact resistance R c , the distributed-current-flow contact model shows that R 23 −R 23collinear  ≪ R c when ρ c is sufficiently small. Indeed, the measured R 23 −R 23collinear  was so small in these devices that it was within the measurement uncertainty, meaning that it was not possible to directly calculate ρ c from these data. However, it was possible to calculate an upper bound on ρ c for each device based on the largest possible value of R 23 −R 23collinear . In addition, we took into account the large uncertainties in the NW transport properties by numerically maximizing ρ c with respect to the uncertainty range of each measured and assumed parameter in the contact model. The resulting upper limits on ρ c ranged from 4.2 × 10 −6  to 7.6 × 10 −6  Ω cm 2 , indicating that 20 nm Ti/200 nm Al is a good choice of ohmic contact for moderately-doped n-GaN NWs. The measurement and numerical analysis demonstrated here offer a general approach to modeling ohmic contact resistivity via NW four

  16. Electrical properties of aluminum contacts deposited by DC sputtering method for photovoltaic applications

    Directory of Open Access Journals (Sweden)

    Krawczak Ewelina

    2017-01-01

    Full Text Available The use of aluminum contacts is common in the process of silicon solar cells production because of low contact resistivity. It has also a great importance in thin film technology for photovoltaics, especially in copper-indium-gallium-diselenide (CIGS devices. The final stage of CIGS cell production is the top contact deposition of high conductivity layer for lateral current collection. Such material has to be highly optically transparent as well. In order to make a contact, metal is deposited onto TCO layer with minimum shadowing to allow as much light as possible into device. The metal grid contact is being made by deposition of few microns of aluminum. The resistivity of the deposited material as well as resistance between the metal grid and TCO layer plays a great role in high quality solar cell production. This paper presents the results of four point probe conductivity analysis of Al thin films deposited by direct current (DC magnetron sputtering method. Influence of technological parameters of the Al deposition process on sheet resistance of deposited layers has been showed. In order to obtain the lowest resistivity of the thin contact layer, optimal set of sputtering parameters, i.e. power applied, deposition time and deposition pressure was found. The resistivity of the contact between two adjacent Al metal fingers deposited onto transparent conductive Al-doped zinc oxide film has been also examined.

  17. Electrical properties of aluminum contacts deposited by DC sputtering method for photovoltaic applications

    Science.gov (United States)

    Krawczak, Ewelina; Gułkowski, Sławomir

    2017-10-01

    The use of aluminum contacts is common in the process of silicon solar cells production because of low contact resistivity. It has also a great importance in thin film technology for photovoltaics, especially in copper-indium-gallium-diselenide (CIGS) devices. The final stage of CIGS cell production is the top contact deposition of high conductivity layer for lateral current collection. Such material has to be highly optically transparent as well. In order to make a contact, metal is deposited onto TCO layer with minimum shadowing to allow as much light as possible into device. The metal grid contact is being made by deposition of few microns of aluminum. The resistivity of the deposited material as well as resistance between the metal grid and TCO layer plays a great role in high quality solar cell production. This paper presents the results of four point probe conductivity analysis of Al thin films deposited by direct current (DC) magnetron sputtering method. Influence of technological parameters of the Al deposition process on sheet resistance of deposited layers has been showed. In order to obtain the lowest resistivity of the thin contact layer, optimal set of sputtering parameters, i.e. power applied, deposition time and deposition pressure was found. The resistivity of the contact between two adjacent Al metal fingers deposited onto transparent conductive Al-doped zinc oxide film has been also examined.

  18. Treatment of Simulated Coalbed Methane Produced Water Using Direct Contact Membrane Distillation

    Directory of Open Access Journals (Sweden)

    Dong-Wan Cho

    2016-05-01

    Full Text Available Expolitation of coalbed methane (CBM involves production of a massive amount saline water that needs to be properly managed for environmental protection. In this study, direct contact membrane distillation (DCMD was utilized for treatment of CBM-produced water to remove saline components in the water. Simulated CBM waters containing varying concentrations of NaCl (1, 20, and 500 mM and NaHCO3 (1 and 25 mM were used as feed solutions under two transmembrane temperatures (Δ40 and 60 °C. In short-term distillation (~360 min, DCMD systems showed good performance with nearly 100% removal of salts for all solutes concentrations at both temperatures. The permeate flux increased with the feed temperature, but at a given temperature, it remained fairly stable throughout the whole operation. A gradual decline in permeate flux was observed at Δ60 °C at high NaHCO3 concentration (25 mM. In long-term distillation (5400 min, the presence of 25 mM NaHCO3 further decreased the flux to 25%–35% of the initial value toward the end of the operation, likely due to membrane fouling by deposition of Ca-carbonate minerals on the pore openings. Furthermore, pore wetting by the scalants occurred at the end of the experiment, and it increased the distillate conducitivity to 110 µS·cm−1. The precipitates formed on the surface were dominantly CaCO3 crystals, identified as aragonite.

  19. Membrane Contact Sites: Complex Zones for Membrane Association and Lipid Exchange

    Science.gov (United States)

    Quon, Evan; Beh, Christopher T.

    2015-01-01

    Lipid transport between membranes within cells involves vesicle and protein carriers, but as agents of nonvesicular lipid transfer, the role of membrane contact sites has received increasing attention. As zones for lipid metabolism and exchange, various membrane contact sites mediate direct associations between different organelles. In particular, membrane contact sites linking the plasma membrane (PM) and the endoplasmic reticulum (ER) represent important regulators of lipid and ion transfer. In yeast, cortical ER is stapled to the PM through membrane-tethering proteins, which establish a direct connection between the membranes. In this review, we consider passive and facilitated models for lipid transfer at PM–ER contact sites. Besides the tethering proteins, we examine the roles of an additional repertoire of lipid and protein regulators that prime and propagate PM–ER membrane association. We conclude that instead of being simple mediators of membrane association, regulatory components of membrane contact sites have complex and multilayered functions. PMID:26949334

  20. Contact spectroscopy of high-temperature superconductors. Review

    International Nuclear Information System (INIS)

    Yanson, I.K.

    1991-01-01

    We have attempted to systematize the research of high temperature superconductors by means of tunneling and point-contact spectroscopy. The theoretical grounds of the methods are briefly described. The deviations of current-voltage characteristics from ordinary superconductors are considered. The properties of point contacts with direct energy gap measurfements and the fine structure of derivatives of i(v) curves at the overlap energies are reviewed for the high-T c La 2-x Sr x CuO 4 materials

  1. The difference of 17% ethylenediaminetetraacetic acid irrigation material contact time of 60 seconds and 30 seconds toward of cleanliness of apical third root canal wall

    Directory of Open Access Journals (Sweden)

    Yunita Wijaya

    2011-11-01

    Full Text Available Root canal preparation is one important step in endodontic treatment, involves the cleaning and the shaping of the root canal debris. Root canal cleaning effectiveness depends on the preparation bio-mechanical and irrigation. Purpose of this study was to evaluate the cleanliness of apical third of root canal wall from of debris, with the contact time of 17% EDTA irrigation material for 60 seconds and 30 seconds after root canal preparation using rotary NiTi instruments. This quasi-experimental study was carried out invitro, with random sampling technique. The sample used was 20 central maxillary incisors that have been extracted and divided into two experimental groups of 10 teeth each. The results were analyzed using student t statistics, showed that the average value of the debris of the two groups differed significantly. The contact time of 60 seconds of 17% EDTA showed cleaner root canal than the 30 seconds. The conclusion of this study was there were the differences of the cleanliness of apical third of the root canal with the 60 seconds contact time of 17% EDTA irrigation materials than 30 seconds contact time.

  2. State-of-the-art and needs for jet instability and direct contact condensation model improvements

    International Nuclear Information System (INIS)

    Bousbia-Salah, A.; Moretti, F.; D'auria, F.; Bousbia-Salah, A.)

    2007-01-01

    There is a common understanding among thermal-hydraulic experts that the system analysis codes have currently reached an acceptable degree of maturity. Reliable application, however, is still limited to the validated domain. There is a growing need for qualified codes in assessing the safety of the existing reactors and for developing advanced reactor systems. Under conditions involving multi-phase flow simulations, the use of classical methods, mainly based upon the one dimensional approach, is not appropriate at all. The use of new computational models, such as the direct numerical simulation, large-eddy simulation or other advanced computational fluid dynamics methods, seems to be more suitable for more complex events. For this purpose, the European Commission financed NURESIM Integrated Project (as a part of the FP6 programme), was adopted to provide the initial step towards a Common European Standard Software Platform for modelling, recording and recovering computer data for nuclear reactor simulations. Some of the studies carried out at the University of Pisa within the framework of the NURESIM project are presented in this paper. They mainly concern the investigation of two critical phenomena connected with jet instabilities and direct contact condensation that occur during emergency core cooling. Through these examples, the state-of-the-art and the need for model improvements and validation against new experimental data for the sake of getting a better understanding and more accurate predictions are discussed. (author)

  3. Elastic contact mechanics: percolation of the contact area and fluid squeeze-out.

    Science.gov (United States)

    Persson, B N J; Prodanov, N; Krick, B A; Rodriguez, N; Mulakaluri, N; Sawyer, W G; Mangiagalli, P

    2012-01-01

    The dynamics of fluid flow at the interface between elastic solids with rough surfaces depends sensitively on the area of real contact, in particular close to the percolation threshold, where an irregular network of narrow flow channels prevails. In this paper, numerical simulation and experimental results for the contact between elastic solids with isotropic and anisotropic surface roughness are compared with the predictions of a theory based on the Persson contact mechanics theory and the Bruggeman effective medium theory. The theory predictions are in good agreement with the experimental and numerical simulation results and the (small) deviation can be understood as a finite-size effect. The fluid squeeze-out at the interface between elastic solids with randomly rough surfaces is studied. We present results for such high contact pressures that the area of real contact percolates, giving rise to sealed-off domains with pressurized fluid at the interface. The theoretical predictions are compared to experimental data for a simple model system (a rubber block squeezed against a flat glass plate), and for prefilled syringes, where the rubber plunger stopper is lubricated by a high-viscosity silicon oil to ensure functionality of the delivery device. For the latter system we compare the breakloose (or static) friction, as a function of the time of stationary contact, to the theory prediction.

  4. Behavior of bone cells in contact with magnesium implant material.

    Science.gov (United States)

    Burmester, Anna; Willumeit-Römer, Regine; Feyerabend, Frank

    2017-01-01

    Magnesium-based implants exhibit several advantages, such as biodegradability and possible osteoinductive properties. Whether the degradation may induce cell type-specific changes in metabolism still remains unclear. To examine the osteoinductivity mechanisms, the reaction of bone-derived cells (MG63, U2OS, SaoS2, and primary human osteoblasts (OB)) to magnesium (Mg) was determined. Mg-based extracts were used to mimic more realistic Mg degradation conditions. Moreover, the influence of cells having direct contact with the degrading Mg metal was investigated. In exposure to extracts and in direct contact, the cells decreased pH and osmolality due to metabolic activity. Proliferating cells showed no significant reaction to extracts, whereas differentiating cells were negatively influenced. In contrast to extract exposure, where cell size increased, in direct contact to magnesium, cell size was stable or even decreased. The amount of focal adhesions decreased over time on all materials. Genes involved in bone formation were significantly upregulated, especially for primary human osteoblasts. Some osteoinductive indicators were observed for OB: (i) an increased cell count after extract addition indicated a higher proliferation potential; (ii) increased cell sizes after extract supplementation in combination with augmented adhesion behavior of these cells suggest an early switch to differentiation; and (iii) bone-inducing gene expression patterns were determined for all analyzed conditions. The results from the cell lines were inhomogeneous and showed no specific stimulus of Mg. The comparison of the different cell types showed that primary cells of the investigated tissue should be used as an in vitro model if Mg is analyzed. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 165-179, 2017. © 2015 Wiley Periodicals, Inc.

  5. Current Enhancement with Contact-Area-Limited Doping for Bottom-Gate, Bottom-Contact Organic Thin-Film Transistors

    Science.gov (United States)

    Noda, Kei; Wakatsuki, Yusuke; Yamagishi, Yuji; Wada, Yasuo; Toyabe, Toru; Matsushige, Kazumi

    2013-02-01

    The current enhancement mechanism in contact-area-limited doping for bottom-gate, bottom-contact (BGBC) p-channel organic thin-film transistors (OTFTs) was investigated both by simulation and experiment. Simulation results suggest that carrier shortage and large potential drop occur in the source-electrode/channel interface region in a conventional BGBC OTFT during operation, which results in a decrease in the effective field-effect mobility. These phenomena are attributed to the low carrier concentration of active semiconductor layers in OTFTs and can be alleviated by contact-area-limited doping, where highly doped layers are prepared over source-drain electrodes. According to two-dimensional current distribution obtained from the device simulation, a current flow from the source electrode to the channel region via highly doped layers is generated in addition to the direct carrier injection from the source electrode to the channel, leading to the enhancement of the drain current and effective field-effect mobility. The expected current enhancement mechanism in contact-area-limited doping was experimentally confirmed in typical α-sexithiophene (α-6T) BGBC thin-film transistors.

  6. Bone char quality and defluoridation capacity in contact precipitation

    DEFF Research Database (Denmark)

    Albertus, J.; Bregnhøj, Henrik; Kongpun, M.

    2002-01-01

    are added as in the contact precipitation process. The results show that the columns are able to remove up to 700 bedvolumes, before the concentration of fluoride in the effluent water breaks through, above 1.5 mg/L. Operational removal capacities observed are 7 and 9 mg/L, depending on contact time...... and the dosage of chemicals. It is discussed that longer contact time and higher dosage of calcium and phosphate may result in longer operation periods in the contact precipitation columns....

  7. Evaporation-induced flow in an inviscid liquid line at any contact angle

    Science.gov (United States)

    Petsi, A. J.; Burganos, V. N.

    2006-04-01

    The problem of potential flow inside an evaporating liquid line, shaped as an infinitely long cylindrical segment lying on a flat surface, is considered and an analytical solution is obtained for any contact angle in (0,π) . In this way, microflow details inside linear liquid bodies evaporating on hydrophilic, hydrophobic, and strongly hydrophobic substrates can now be obtained. The mathematical formulation employs the velocity potential and stream function formulations in bipolar coordinates and the solution is obtained using the technique of Fourier transform. Both pinned and depinned contact lines are considered. The solution is applicable to any evaporation mechanism but for illustration purposes numerical results are presented here for the particular case of kinetically controlled evaporation. For hydrophilic substrates, the flow inside the evaporating liquid line is directed towards the edges for pinned contact lines, thus, promoting a coffee stain effect. The opposite flow direction is observed for depinned contact lines. However, for strongly hydrophobic substrates, flow is directed outwards for both pinned and depinned contact lines, but owing to its low magnitude compared to that on hydrophilic substrates, a craterlike colloidal deposit should be expected rather than a ringlike deposit, in agreement with experimental observations.

  8. Hopf bifurcation analysis of Chen circuit with direct time delay feedback

    International Nuclear Information System (INIS)

    Hai-Peng, Ren; Wen-Chao, Li; Ding, Liu

    2010-01-01

    Direct time delay feedback can make non-chaotic Chen circuit chaotic. The chaotic Chen circuit with direct time delay feedback possesses rich and complex dynamical behaviours. To reach a deep and clear understanding of the dynamics of such circuits described by delay differential equations, Hopf bifurcation in the circuit is analysed using the Hopf bifurcation theory and the central manifold theorem in this paper. Bifurcation points and bifurcation directions are derived in detail, which prove to be consistent with the previous bifurcation diagram. Numerical simulations and experimental results are given to verify the theoretical analysis. Hopf bifurcation analysis can explain and predict the periodical orbit (oscillation) in Chen circuit with direct time delay feedback. Bifurcation boundaries are derived using the Hopf bifurcation analysis, which will be helpful for determining the parameters in the stabilisation of the originally chaotic circuit

  9. Modélisation d'une détente quasi-isotherme d'un gaz par contact direct avec un fluide caloporteur

    OpenAIRE

    Blaise , Mathilde; Maillet , Denis; Feidt , Michel; Alemany , Antoine; Forcinetti , Renato

    2015-01-01

    National audience; Les besoins en électricité sont croissants, cependant, les rejets thermiques industriels sont peu valorisés. La reconsidération des moteurs à apport de chaleur externe est un enjeu d'actualité pour la valorisation des rejets thermiques. Dans ces derniers, la phase de détente motrice offre des possibilités d'amélioration. L'idée ici est d'accompagner cette étape par un apport de chaleur par contact direct avec un fluide caloporteur. En effet, la détente d'un gaz entre une ha...

  10. Prevalence of non-contact and contact childhood sexual abuse: An Internet-based sample of men who have sex with men in China.

    Directory of Open Access Journals (Sweden)

    Wenjian Xu

    Full Text Available The prevalence of childhood sexual abuse (CSA is high among Western men who have sex with men (MSM, and CSA is associated with certain socio-demographic variables and with human immunodeficiency virus (HIV status. Little is known about CSA among Chinese MSM; therefore, we explored the prevalence and frequency of non-contact (e.g., sexual invitations, exhibitionism and contact (e.g., intercourse, genital contact forms of CSA in an Internet-based sample of MSM in China. We also examined the associations between the participants' socio-demographic characteristics and HIV status, and their histories of CSA.We surveyed MSM from 30 Chinese provinces in 2014-2015; 1,030 (mean age = 25.15 years, SD = 6.32 and 1,020 (mean age = 25.05 years, SD = 5.95 respondents were eligible for inclusion in the non-contact and contact CSA groups, respectively.Prevalence of non-contact and contact CSA was 36.2% and 29.8%, respectively; 20.4% and 15.0% had experienced non-contact and contact CSA ≥ 3 times, respectively. Most respondents were young adults, well educated, single, had never "come out," and self-identified as gay or bisexual men. Univariate analyses showed that respondents who had experienced contact CSA were more likely to be HIV-positive than those who had never experienced contact CSA. Multivariate analyses showed that non-contact CSA was associated with less education, being in a relationship with a woman or a man, and having "come out." Contact CSA was associated with less education, higher income, and being in a relationship with a man. Respondents who had experienced non-contact CSA ≥ 3 times were more likely to be less educated, "out," and to be in a relationship with a woman or a man. Respondents who had experienced contact CSA ≥ 3 times were more likely to be less educated and to be in a relationship with a man.It is necessary to pay closer attention to CSA among MSM and other sexual minorities in China.

  11. When do gamblers help themselves? Self-discontinuity increases self-directed change over time.

    Science.gov (United States)

    Kim, Hyoun S; Wohl, Michael J A; Salmon, Melissa; Santesso, Diane

    2017-01-01

    Most disordered gamblers fail to take the necessary action to change their behavior. When action is taken, it is typically done under self-direction. Yet, little is known about what motivates gamblers to engage in self-directed change as researchers have focused almost exclusively on barriers to treatment seeking. Herein, we tested whether self-discontinuity (i.e., the notion that the self has undergone fundamental changes as a result of one's gambling) predicts self-directed change among gamblers experiencing sub-clinical levels of disordered gambling. Further, we tested whether this relationship would hold when controlling for feelings of shame and guilt about one's gambling as well as self-stigma as a disordered gambler (i.e., known barriers to change). To this end, 195 gamblers from the community completed a questionnaire battery that contained the variables of interest. Six months later, participants were re-contacted to assess whether they engaged in self-directed change. As hypothesized, the likelihood that self-directed change was attempted increased to the extent participants reported feeling self-discontinuous - an effect that remained significant when controlling for shame, guilt, and self-stigma. Results suggest that heightening the awareness that the gambling has fundamentally changed the self increases the likelihood of gamblers taking action to change their disordered gambling behaviors. Copyright © 2016. Published by Elsevier Ltd.

  12. Whither papillon? Future directions for contact radiotherapy in rectal cancer

    DEFF Research Database (Denmark)

    Lindegaard, J; Gerard, J P; Sun Myint, A

    2007-01-01

    of rectal cancer. As a result of these efforts, a European company is starting production of the new Papillon RT-50 machine, which will be available shortly. In addition, the ICONE group is planning an observational study on contact X-ray and transanal endoscopic microsurgery (CONTEM) for curative treatment...... of rectal cancer. This protocol will ensure standardised diagnostic procedures, patient selection and treatment in centres across the world and the data will be collected prospectively for analysis and audit. It is hoped that the CONTEM trial will provide the scientific evidence that is needed to obtain...

  13. The contact area and sliding friction in nanotribological systems

    International Nuclear Information System (INIS)

    Wolloch, M.

    2014-01-01

    Although friction, wear, and lubrication have been investigated for hundreds of years, many important questions in the field, now dubbed tribology, remain open. Two of these are the determination of the real area of contact and the direction dependence of friction forces on the nanoscale, which are investigated in this thesis. The invention of the atomic force microscope (AFM) in 1986 by Binnig , Quate, and Gerber was invaluable for the investigation of frictional forces on the atomic scale, giving a boost to the emerging field of nanotribology. While experimental AFM set-ups where quickly modeled with classical molecular dynamic (MD) simulations, the use of 'ab-initio' methods on tribological problems remained scarce until recently. In this thesis density functional theory (DFT) is used to develop parameter free methods in the field of nanotribology. Since the discovery that the apparent area of contact can be orders of magnitude larger than the true area of contact, the definition and determination of the latter has been an important topic of research. While classical contact mechanics provides satisfactory theories and results for various macroscopic systems, the application of these methods to atomistic systems is dubious, as the contacting bodies are not continuous at this length scale. We developed a parameter free approach to define and calculate the real area of contact between two bodies depending on distance. Strong relaxations at distinct distances, like the j ump to contact , which is often observed in AFM experiments, are used to define the onset of contact and Bader-s Quantum Theory of Atoms in Molecules is used to calculate the real area of contact at a given distance. Bader's method partitions the charge density ρ unambiguously into atoms, which theoretically fill all space and thus give non zero contact areas for all distances. It is therefore necessary to use a density cutoff ρ cut which assigns all regions in space where ρ <

  14. Moving contact lines on vibrating surfaces

    Science.gov (United States)

    Solomenko, Zlatko; Spelt, Peter; Scott, Julian

    2017-11-01

    Large-scale simulations of flows with moving contact lines for realistic conditions generally requires a subgrid scale model (analyses based on matched asymptotics) to account for the unresolved part of the flow, given the large range of length scales involved near contact lines. Existing models for the interface shape in the contact-line region are primarily for steady flows on homogeneous substrates, with encouraging results in 3D simulations. Introduction of complexities would require further investigation of the contact-line region, however. Here we study flows with moving contact lines on planar substrates subject to vibrations, with applications in controlling wetting/dewetting. The challenge here is to determine the change in interface shape near contact lines due to vibrations. To develop further insight, 2D direct numerical simulations (wherein the flow is resolved down to an imposed slip length) have been performed to enable comparison with asymptotic theory, which is also developed further. Perspectives will also be presented on the final objective of the work, which is to develop a subgrid scale model that can be utilized in large-scale simulations. The authors gratefully acknowledge the ANR for financial support (ANR-15-CE08-0031) and the meso-centre FLMSN for use of computational resources. This work was Granted access to the HPC resources of CINES under the allocation A0012B06893 made by GENCI.

  15. Leukotriene B₄-leukotriene B₄ receptor axis promotes oxazolone-induced contact dermatitis by directing skin homing of neutrophils and CD8⁺ T cells.

    Science.gov (United States)

    Lv, Jiaoyan; Zou, Linlin; Zhao, Lina; Yang, Wei; Xiong, Yingluo; Li, Bingji; He, Rui

    2015-09-01

    Leukotriene B4 (LTB4 ) is a lipid mediator that is rapidly generated in inflammatory sites, and its functional receptor, BLT1, is mostly expressed on immune cells. Contact dermatitis is a common inflammatory skin disease characterized by skin oedema and abundant inflammatory infiltrates, primarily including neutrophils and CD8(+) T cells. The role of the LTB4 -BLT1 axis in contact dermatitis remains largely unknown. In this study, we found up-regulated gene expression of 5-lipoxygenase and leukotriene A4 hydrolase, two critical enzymes for LTB4 synthesis, BLT1 and elevated LTB4 levels in skin lesions of oxazolone (OXA)-induced contact dermatitis. BLT1 deficiency or blockade of LTB4 and BLT1 by the antagonists, bestatin and U-75302, respectively, in the elicitation phase caused significant decreases in ear swelling and skin-infiltrating neutrophils and CD8(+) T cells, which was accompanied by significantly reduced skin expression of CXCL1, CXCL2, interferon-γ and interleukin-1β. Furthermore, neutrophil depletion during the elicitation phase of OXA-induced contact dermatitis also caused significant decreases in ear swelling and CD8(+) T-cell infiltration accompanied by significantly decreased LTB4 synthesis and gene expression of CXCL2, interferon-γ and interleukin-1β. Importantly, subcutaneous injection of exogenous LTB4 restored the skin infiltration of CD8(+) T cells in neutrophil-depleted mice following OXA challenge. Collectively, our results demonstrate that the LTB4 -BLT1 axis contributes to OXA-induced contact dermatitis by mediating skin recruitment of neutrophils, which are a major source of LTB4 that sequentially direct CD8(+) T-cell homing to OXA-challenged skin. Hence, LTB4 and BLT1 could be potential therapeutic targets for the treatment of contact dermatitis. © 2015 John Wiley & Sons Ltd.

  16. Real-Time Polymerase Chain Reaction-Based Detection of Bordetella pertussis in Mexican Infants and Their Contacts: A 3-Year Multicenter Study.

    Science.gov (United States)

    Aquino-Andrade, Alejandra; Martínez-Leyva, Gabriel; Mérida-Vieyra, Jocelin; Saltigeral, Patricia; Lara, Antonino; Domínguez, Wendy; García de la Puente, Silvestre; De Colsa, Agustín

    2017-09-01

    To evaluate the usefulness of real-time polymerase chain reaction (RT-PCR) as a diagnostic method for the detection of Bordetella pertussis in hospitalized patients aged pertussis detection and symptoms in household contacts of patients diagnosed with pertussis were studied. A total of 286 patients were included; of these, 67.1% had B pertussis and 4.5% had Bordetella spp. Complications occurred in 20% of patients, and the mortality rate was 6.7%. Of 434 contacts studied, 111 were mothers of study infants, representing the most frequently B pertussis-infected group and the main symptomatic contact. The use of RT-PCR permits improved detection and diagnosis of pertussis and a better understanding of the epidemiology of sources of infection. The complications and mortality rate of pertussis continue to be high. Household contacts are confirmed as a frequent source of infection of B pertussis in young children. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  17. Direct Observation of 2D Electrostatics and Ohmic Contacts in Template-Grown Graphene/WS2 Heterostructures.

    Science.gov (United States)

    Zheng, Changxi; Zhang, Qianhui; Weber, Bent; Ilatikhameneh, Hesameddin; Chen, Fan; Sahasrabudhe, Harshad; Rahman, Rajib; Li, Shiqiang; Chen, Zhen; Hellerstedt, Jack; Zhang, Yupeng; Duan, Wen Hui; Bao, Qiaoliang; Fuhrer, Michael S

    2017-03-28

    Large-area two-dimensional (2D) heterojunctions are promising building blocks of 2D circuits. Understanding their intriguing electrostatics is pivotal but largely hindered by the lack of direct observations. Here graphene-WS 2 heterojunctions are prepared over large areas using a seedless ambient-pressure chemical vapor deposition technique. Kelvin probe force microscopy, photoluminescence spectroscopy, and scanning tunneling microscopy characterize the doping in graphene-WS 2 heterojunctions as-grown on sapphire and transferred to SiO 2 with and without thermal annealing. Both p-n and n-n junctions are observed, and a flat-band condition (zero Schottky barrier height) is found for lightly n-doped WS 2 , promising low-resistance ohmic contacts. This indicates a more favorable band alignment for graphene-WS 2 than has been predicted, likely explaining the low barriers observed in transport experiments on similar heterojunctions. Electrostatic modeling demonstrates that the large depletion width of the graphene-WS 2 junction reflects the electrostatics of the one-dimensional junction between two-dimensional materials.

  18. Contact statuses between functionally graded brake disk and pure pad disk

    International Nuclear Information System (INIS)

    Shahzamanian, M.M.; Sahari, B.B.; Bayat, M.; Mustapha, F.; Ismarrubie, Z.N.; Shahrjerdi, A.

    2009-01-01

    Full text: The contact statuses between functionally graded (FG) brake disks and pure pad disk are investigated by using finite element method (FEM). Two types of variation is considered for FG brake disk, the variation of materials are considered change in radial and thickness direction of disk. The material properties of these two types of FG brake disks are assumed to be represented by power-law distributions in the radius and thickness direction. The results are obtained and then compared. For the radial FG brake disk, the inner and outer surfaces are considered metal and ceramic respectively, and friction coefficient between metal surface and ceramic surface of FG brake dick with pad are considered 1.4 and 0.75 respectively. For the thickness FG brake disk the contact surface with pure pad brake disk is ceramic and the free surface is metal and friction coefficient between ceramic (contact) surface and pure pad brake disk is considered 0.75. In both types of FG brake disks the Coulomb contact friction is applied. Mechanical response of FG brake disks are compared and verified with the known results in the literatures. Three types of contact statuses are introduced as Sticking, Contact and Near Contact. The contact status between pad and disk for different values for pad thickness, grading index,n , and percentage of friction coefficient (λ) is shown. It can be seen that for all values of percentage of friction coefficient,λ , and grading indices, n, by increasing the thickness of pad cause the contact status changes from sticking to contact and then to near contact. (author)

  19. Non-contact acquisition of respiration and heart rates using Doppler radar with time domain peak-detection algorithm.

    Science.gov (United States)

    Xiaofeng Yang; Guanghao Sun; Ishibashi, Koichiro

    2017-07-01

    The non-contact measurement of the respiration rate (RR) and heart rate (HR) using a Doppler radar has attracted more attention in the field of home healthcare monitoring, due to the extremely low burden on patients, unconsciousness and unconstraint. Most of the previous studies have performed the frequency-domain analysis of radar signals to detect the respiration and heartbeat frequency. However, these procedures required long period time (approximately 30 s) windows to obtain a high-resolution spectrum. In this study, we propose a time-domain peak detection algorithm for the fast acquisition of the RR and HR within a breathing cycle (approximately 5 s), including inhalation and exhalation. Signal pre-processing using an analog band-pass filter (BPF) that extracts respiration and heartbeat signals was performed. Thereafter, the HR and RR were calculated using a peak position detection method, which was carried out via LABVIEW. To evaluate the measurement accuracy, we measured the HR and RR of seven subjects in the laboratory. As a reference of HR and RR, the persons wore contact sensors i.e., an electrocardiograph (ECG) and a respiration band. The time domain peak-detection algorithm, based on the Doppler radar, exhibited a significant correlation coefficient of HR of 0.92 and a correlation coefficient of RR of 0.99, between the ECG and respiration band, respectively.

  20. A longitudinal exploration of pain tolerance and participation in contact sports.

    Science.gov (United States)

    Thornton, Claire; Sheffield, David; Baird, Andrew

    2017-07-01

    Athletes who choose to engage in contact sports do so with the knowledge that participation will bring pain in the form of contact with others, injury, and from exertion. Whilst athletes who play contact sports have been shown to have higher pain tolerance than those who do not, it is unclear whether this is a result of habituation over time, or as a result of individual differences at the outset. The aim was to compare pain responses over an athletic season in athletes who participated in contact sport and those who disengaged from it. One hundred and two new contact athletes completed measures of cold and ischaemic pain tolerance, perceived pain intensity, pain bothersomeness, pain coping styles and attendance at the start, middle (4 months) and end (8 months) of their season. The athletes were drawn from martial arts, rugby and American football. Cluster analysis placed 47 athletes into a participating category and 55 into a non-participating cluster. Participating athletes had higher ischaemic pain tolerance at the start (r=0.27, p=0.05), middle (r=0.41, pdirect coping, catastrophized less about injury pain and also found contact pain to be less bothersome physically and psychologically compared to non-participating athletes. Participating athletes were more tolerant of ischaemic pain at the end of the season compared to the start (r=0.28, p=0.04). Conversely non-participating athletes became significantly less tolerant to both pain stimuli by the end of the season (cold pressor; r=0.54, psports become less pain tolerant of experimental pain, possibly a result of catastrophizing. The results suggest that athletes who commit to contact sports find pain less bothersome over time, possibly as a result of experience and learning to cope with pain. Athletes who continue to participate in contact sports have a higher pain tolerance, report less bothersomeness and have higher direct coping than those who drop out. In addition, tolerance to ischaemic pain increased

  1. Molecular dynamics study of contact mechanics: contact area and interfacial separation from small to full contact

    OpenAIRE

    Yang, C.; Persson, B. N. J.

    2007-01-01

    We report a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. We study the contact area and the interfacial separation from small contact (low load) to full contact (high load). For small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For high load the contact area approaches to the nominal contact area (i.e., complete contact), and the i...

  2. Ion-Induced Surface Modification of Magnetically Operated Contacts

    Directory of Open Access Journals (Sweden)

    Karen Arushanov

    2012-02-01

    Full Text Available A study has been made of permalloy (iron-nickel contacts of reed switches before and after ion-induced surface modification using atomic force and optical microscopy, Auger electron and X-ray photoelectron spectroscopy. It has been found that the formation of surface nitride layers enhances corrosion and erosion resistance of contacts. We proposed to produce such layers directly into sealed reed switches by means of pulsing glow-discharge nitrogen plasma.

  3. A comparison of stresses in molar teeth restored with inlays and direct restorations, including polymerization shrinkage of composite resin and tooth loading during mastication.

    Science.gov (United States)

    Dejak, Beata; Młotkowski, Andrzej

    2015-03-01

    Polymerization shrinkage of composites is one of the main causes of leakage around dental restorations. Despite the large numbers of studies there is no consensus, what kind of teeth reconstruction--direct or indirect composite restorations are the most beneficial and the most durable. The aim was to compare equivalent stresses and contact adhesive stresses in molar teeth with class II MOD cavities, which were restored with inlays and direct restorations (taking into account polymerization shrinkage of composite resin) during simulated mastication. The study was conducted using the finite elements method with the application of contact elements. Three 3D models of first molars were created: model A was an intact tooth; model B--a tooth with a composite inlay, and model C--a tooth with a direct composite restoration. Polymerization linear shrinkage 0.7% of a direct composite restoration and resin luting cement was simulated (load 1). A computer simulation of mastication was performed (load 2). In these 2 situations, equivalent stresses according to the modified von Mises criterion (mvM) in the materials of mandibular first molar models with different restorations were calculated and compared. Contact stresses in the luting cement-tooth tissue adhesive interface around the restorations were also assessed and analyzed. Equivalent stresses in a tooth with a direct composite restoration (the entire volume of which was affected by polymerization shrinkage) were many times higher than in the tooth restored with a composite inlay (where shrinkage was present only in a thin layer of the luting cement). In dentin and enamel the stress values were 8-14 times higher, and were 13 times higher in the direct restoration than in the inlay. Likewise, contact stresses in the adhesive bond around the direct restoration were 6.5-7.7 times higher compared to an extraorally cured restoration. In the masticatory simulation, shear contact stresses in the adhesive bond around the direct

  4. Direct observation of both contact and remote oxygen scavenging of GeO2 in a metal-oxide-semiconductor stack

    International Nuclear Information System (INIS)

    Fadida, S.; Shekhter, P.; Eizenberg, M.; Cvetko, D.; Floreano, L.; Verdini, A.; Nyns, L.; Van Elshocht, S.; Kymissis, I.

    2014-01-01

    In the path to incorporating Ge based metal-oxide-semiconductor into modern nano-electronics, one of the main issues is the oxide-semiconductor interface quality. Here, the reactivity of Ti on Ge stacks and the scavenging effect of Ti were studied using synchrotron X-ray photoelectron spectroscopy measurements, with an in-situ metal deposition and high resolution transmission electron microscopy imaging. Oxygen removal from the Ge surface was observed both in direct contact as well as remotely through an Al 2 O 3 layer. The scavenging effect was studied in situ at room temperature and after annealing. We find that the reactivity of Ti can be utilized for improved scaling of Ge based devices.

  5. Optimal contact definition for reconstruction of Contact Maps

    Directory of Open Access Journals (Sweden)

    Stehr Henning

    2010-05-01

    Full Text Available Abstract Background Contact maps have been extensively used as a simplified representation of protein structures. They capture most important features of a protein's fold, being preferred by a number of researchers for the description and study of protein structures. Inspired by the model's simplicity many groups have dedicated a considerable amount of effort towards contact prediction as a proxy for protein structure prediction. However a contact map's biological interest is subject to the availability of reliable methods for the 3-dimensional reconstruction of the structure. Results We use an implementation of the well-known distance geometry protocol to build realistic protein 3-dimensional models from contact maps, performing an extensive exploration of many of the parameters involved in the reconstruction process. We try to address the questions: a to what accuracy does a contact map represent its corresponding 3D structure, b what is the best contact map representation with regard to reconstructability and c what is the effect of partial or inaccurate contact information on the 3D structure recovery. Our results suggest that contact maps derived from the application of a distance cutoff of 9 to 11Å around the Cβ atoms constitute the most accurate representation of the 3D structure. The reconstruction process does not provide a single solution to the problem but rather an ensemble of conformations that are within 2Å RMSD of the crystal structure and with lower values for the pairwise average ensemble RMSD. Interestingly it is still possible to recover a structure with partial contact information, although wrong contacts can lead to dramatic loss in reconstruction fidelity. Conclusions Thus contact maps represent a valid approximation to the structures with an accuracy comparable to that of experimental methods. The optimal contact definitions constitute key guidelines for methods based on contact maps such as structure prediction through

  6. Existence for viscoplastic contact with Coulomb friction problems

    Directory of Open Access Journals (Sweden)

    Amina Amassad

    2002-01-01

    frictional contact between an elastic-viscoplastic body and a rigid obstacle. We model the frictional contact both by a Tresca's friction law and a regularized Coulomb's law. We assume, in a first part, that the contact is bilateral and that no separation takes place. In a second part, we consider the Signorini unilateral contact conditions. Proofs are based on a time-discretization method, Banach and Schauder fixed point theorems.

  7. A non-contact time-domain scanning brain imaging system: first in-vivo results

    Science.gov (United States)

    Mazurenka, M.; Di Sieno, L.; Boso, G.; Contini, D.; Pifferi, A.; Dalla Mora, A.; Tosi, A.; Wabnitz, H.; Macdonald, R.

    2013-06-01

    We present results of first in-vivo tests of an optical non-contact scanning imaging system, intended to study oxidative metabolism related processes in biological tissue by means of time-resolved near-infrared spectroscopy. Our method is a novel realization of the short source-detector separation approach and based on a fast-gated single-photon avalanche diode to detect late photons only. The scanning system is built in quasi-confocal configuration and utilizes polarizationsensitive detection. It scans an area of 4×4 cm2, recording images with 32×32 pixels, thus creating a high density of source-detector pairs. To test the system we performed a range of in vivo measurements of hemodynamic changes in several types of biological tissues, i.e. skin (Valsalva maneuver), muscle (venous and arterial occlusions) and brain (motor and cognitive tasks). Task-related changes in hemoglobin concentrations were clearly detected in skin and muscle. The brain activation shows weaker, but yet detectable changes. These changes were localized in pixels near the motor cortex area (C3). However, it was found that even very short hair substantially impairs the measurement. Thus the applicability of the scanner is limited to hairless parts of body. The results of our first in-vivo tests prove the feasibility of non-contact scanning imaging as a first step towards development of a prototype for biological tissue imaging for various medical applications.

  8. Membrane Contact Sites: Complex Zones for Membrane Association and Lipid Exchange

    OpenAIRE

    Evan Quon; Christopher T. Beh

    2016-01-01

    Lipid transport between membranes within cells involves vesicle and protein carriers, but as agents of nonvesicular lipid transfer, the role of membrane contact sites has received increasing attention. As zones for lipid metabolism and exchange, various membrane contact sites mediate direct associations between different organelles. In particular, membrane contact sites linking the plasma membrane (PM) and the endoplasmic reticulum (ER) represent important regulators of lipid and ion transfer...

  9. Contact angle and local wetting at contact line.

    Science.gov (United States)

    Li, Ri; Shan, Yanguang

    2012-11-06

    This theoretical study was motivated by recent experiments and theoretical work that had suggested the dependence of the static contact angle on the local wetting at the triple-phase contact line. We revisit this topic because the static contact angle as a local wetting parameter is still not widely understood and clearly known. To further clarify the relationship of the static contact angle with wetting, two approaches are applied to derive a general equation for the static contact angle of a droplet on a composite surface composed of heterogeneous components. A global approach based on the free surface energy of a thermodynamic system containing the droplet and solid surface shows the static contact angle as a function of local surface chemistry and local wetting state at the contact line. A local approach, in which only local forces acting on the contact line are considered, results in the same equation. The fact that the local approach agrees with the global approach further demonstrates the static contact angle as a local wetting parameter. Additionally, the study also suggests that the wetting described by the Wenzel and Cassie equations is also the local wetting of the contact line rather than the global wetting of the droplet.

  10. The Russian Accusative and Locative and Their Relation to Time and Space

    DEFF Research Database (Denmark)

    Lorentzen, Elena; Durst-Andersen, Per

    2017-01-01

    The paper analyzes the uses of the Russian accusative and locative in which they are directly opposed to one another. It is demonstrated that in spatial contexts the accusative denotes change of contact, whereas the locative denotes permanent contact. This is a manifestation of the crucial...... as location or a set of elements. This means that the accusative is alone in expressing time in its own right, where the speaker makes contact with a time line. In addition, the semantic contribution of the prepositions v ‘in’ and na ‘on’ to the accusative and locative cases is shown....

  11. Mining Important Nodes in Directed Weighted Complex Networks

    Directory of Open Access Journals (Sweden)

    Yunyun Yang

    2017-01-01

    Full Text Available In complex networks, mining important nodes has been a matter of concern by scholars. In recent years, scholars have focused on mining important nodes in undirected unweighted complex networks. But most of the methods are not applicable to directed weighted complex networks. Therefore, this paper proposes a Two-Way-PageRank method based on PageRank for further discussion of mining important nodes in directed weighted complex networks. We have mainly considered the frequency of contact between nodes and the length of time of contact between nodes. We have considered the source of the nodes (in-degree and the whereabouts of the nodes (out-degree simultaneously. We have given node important performance indicators. Through numerical examples, we analyze the impact of variation of some parameters on node important performance indicators. Finally, the paper has verified the accuracy and validity of the method through empirical network data.

  12. Automated real-time search and analysis algorithms for a non-contact 3D profiling system

    Science.gov (United States)

    Haynes, Mark; Wu, Chih-Hang John; Beck, B. Terry; Peterman, Robert J.

    2013-04-01

    The purpose of this research is to develop a new means of identifying and extracting geometrical feature statistics from a non-contact precision-measurement 3D profilometer. Autonomous algorithms have been developed to search through large-scale Cartesian point clouds to identify and extract geometrical features. These algorithms are developed with the intent of providing real-time production quality control of cold-rolled steel wires. The steel wires in question are prestressing steel reinforcement wires for concrete members. The geometry of the wire is critical in the performance of the overall concrete structure. For this research a custom 3D non-contact profilometry system has been developed that utilizes laser displacement sensors for submicron resolution surface profiling. Optimizations in the control and sensory system allow for data points to be collected at up to an approximate 400,000 points per second. In order to achieve geometrical feature extraction and tolerancing with this large volume of data, the algorithms employed are optimized for parsing large data quantities. The methods used provide a unique means of maintaining high resolution data of the surface profiles while keeping algorithm running times within practical bounds for industrial application. By a combination of regional sampling, iterative search, spatial filtering, frequency filtering, spatial clustering, and template matching a robust feature identification method has been developed. These algorithms provide an autonomous means of verifying tolerances in geometrical features. The key method of identifying the features is through a combination of downhill simplex and geometrical feature templates. By performing downhill simplex through several procedural programming layers of different search and filtering techniques, very specific geometrical features can be identified within the point cloud and analyzed for proper tolerancing. Being able to perform this quality control in real time

  13. A novel multi-stage direct contact membrane distillation module: Design, experimental and theoretical approaches

    KAUST Repository

    Lee, Jung Gil

    2016-10-24

    An economic desalination system with a small scale and footprint for remote areas, which have a limited and inadequate water supply, insufficient water treatment and low infrastructure, is strongly demanded in the desalination markets. Here, a direct contact membrane distillation (DCMD) process has the simplest configuration and potentially the highest permeate flux among all of the possible MD processes. This process can also be easily instituted in a multi-stage manner for enhanced compactness, productivity, versatility and cost-effectiveness. In this study, an innovative, multi-stage, DCMD module under countercurrent-flow configuration is first designed and then investigate both theoretically and experimentally to identify its feasibility and operability for desalination application. Model predictions and measured data for mean permeate flux are compared and shown to be in good agreement. The effect of the number of module stages on the mean permeate flux, performance ratio and daily water production of the MDCMD system has been theoretically identified at inlet feed and permeate flow rates of 1.5 l/min and inlet feed and permeate temperatures of 70 °C and 25 °C, respectively. The daily water production of a three-stage DCMD module with a membrane area of 0.01 m2 at each stage is found to be 21.5 kg.

  14. Refinements to calandria tube - liquid injection nozzle (CT-LIN) contact assessments

    International Nuclear Information System (INIS)

    Sedran, P.J.

    2012-01-01

    In recent years, the issue of CT-LIN contact, which first gained attention in 1989, has been addressed through CT-LIN gap measurements, followed by analytical predictions of time-to-contact. CT-LIN time-to-contact predictions have been preformed independently by CPUS Limited for Point Lepreau and Gentilly-2 and by AECL Sheridan Park (now Candu Energy Inc.) for Bruce Power and Gentilly-2. Both companies used the CDEPTH code in combination with CT-LIN gap measurements. Subsequent to the assessments for Point Lepreau and Gentilly-2, a recommended approach for future assessments was presented at the 2008 CANDU maintenance conference. Since that time, a number of refinements to the overall strategy for predicting CT-LIN time-to-contact have been developed and are outlined in this paper. The refinements include: 1. The use of ultrasonic LIN elevation measurements to confirm LIN creep sag behaviour 2. The development of a non-linear empirical CT Creep Sag Model 3. The development of a rationale for discrepancies observed in repeated optical CT-LIN gap measurements and a discussion of alternative CT-LIN gap measurements With these refinements, more accurate CT-LIN time-to-contact predictions can be obtained. For stations that plan to refurbish by 210,000 EFPH, the improvement in time-to-contact predictions resulting from the fore mentioned refinements will not be of any real benefit.. However, for stations that are planning life extensions in order to operate beyond 210,000 EFPH, CT-LIN contact will be an issue. For these stations, improvements in CT-LIN contact time predictions would be beneficial. This paper presents a summary of the proposed refinements and demonstrates how they would impact CT-LIN time-to-contact predictions. (author)

  15. Assessment of Influence of Contact Time between Alginate and Type III Dental Stone on Properties of Cast Model: An in vitro Study.

    Science.gov (United States)

    Dev, Shruti; Kar, Aswini K; Garhnayak, Mirna; Garhnayak, Lokanath; Dhal, Angurbala

    2017-10-01

    Alginate is a versatile, irreversible hydrocolloid impression material, which is cost-effective and forms an essential component in dental practice. For elevating the hardness of the cast models, hardeners are combined with stone. Hence, we planned the present study to evaluate the impact of altering the time of contact between alginate and stone after various interim periods. The present study included the assessment of impact of time of contact between alginate and stone by the construction of 90 casts using a cylinder model. Two bisecting lines were marked and were named as y and y'. These lines were used for testing the dimensional stability. Using chemically cured acrylic resin, the construction of ten special trays was done. All the impression casts were randomly divided into two study groups, with 45 casts in each group-group I: control group, casts were removed after 60 minutes; group II: study group, casts were removed after 9 hours. A digital caliper was used for measuring the dimensional stability of the cast. All the data were collected and analyzed. In the specimens of the control group (group I) and the study group (group II), the mean dimensions from y to y' were found to be 17.54 and 17.95 respectively. The mean reading of hardness in the control group and study group was found to be 0.59 and 0.20 respectively. In groups I and II, the number of specimens showing clarity of two lines (X and X") was 0 and 5 respectively. There was no change in the dimensional stability of the dental stone model when the contact time was increased. Within certain limits, the contact time between alginate and stone can be altered without significantly altering the properties of the cast.

  16. A direct electron detector for time-resolved MeV electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Vecchione, T.; Denes, P.; Jobe, R. K.; Johnson, I. J.; Joseph, J. M.; Li, R. K.; Perazzo, A.; Shen, X.; Wang, X. J.; Weathersby, S. P.; Yang, J.; Zhang, D.

    2017-03-01

    The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μmμm spatial resolution and less than 20 analogue-to-digital converter count RMS pixel noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.

  17. Circadian-Time Sickness: Time-of-Day Cue-Conflicts Directly Affect Health.

    Science.gov (United States)

    van Ee, Raymond; Van de Cruys, Sander; Schlangen, Luc J M; Vlaskamp, Björn N S

    2016-11-01

    A daily rhythm that is not in synchrony with the environmental light-dark cycle (as in jetlag and shift work) is known to affect mood and health through an as yet unresolved neural mechanism. Here, we combine Bayesian probabilistic 'cue-conflict' theory with known physiology of the biological clock of the brain, entailing the insight that, for a functional pacemaker, it is sufficient to have two interacting units (reflecting environmental and internal time-of-day cues), without the need for an extra homuncular directing unit. Unnatural light-dark cycles cause a time-of-day cue-conflict that is reflected by a desynchronization between the ventral (environmental) and dorsal (internal) pacemaking signals of the pacemaker. We argue that this desynchronization, in-and-of-itself, produces health issues that we designate as 'circadian-time sickness', analogous to 'motion sickness'. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Granular contact dynamics using mathematical programming methods

    DEFF Research Database (Denmark)

    Krabbenhoft, K.; Lyamin, A. V.; Huang, J.

    2012-01-01

    granular contact dynamics formulation uses an implicit time discretization, thus allowing for large time steps. Moreover, in the limit of an infinite time step, the general dynamic formulation reduces to a static formulation that is useful in simulating common quasi-static problems such as triaxial tests...... is developed and it is concluded that the associated sliding rule, in the context of granular contact dynamics, may be viewed as an artifact of the time discretization and that the use of an associated flow rule at the particle scale level generally is physically acceptable. (C) 2012 Elsevier Ltd. All rights...

  19. Contact and Non-contact Measurements of Grinding Pins

    Directory of Open Access Journals (Sweden)

    Magdziak Marek

    2015-01-01

    Full Text Available The paper presents the results of contact and non-contact measurements of external profiles of selected grinding pins. The measurements were conducted in order to choose the appropriate measuring technique in the case of the considered measurement task. In the case of contact measurements the coordinate measuring machine ACCURA II was applied. The used coordinate measuring machine was equipped with the contact scanning probe VAST XT and the Calypso inspection software. Contact coordinate measurements were performed by using of different measurement strategies. The applied strategies included different scanning velocities and distances between measured points. Non-contact measurements were conducted by means of the tool presetter produced by the Mahr company. On the basis of gained results the guidelines concerning measurements of grinding pins were formulated. The measurements of analyzed grinding pins performed by means of the non-contact measuring system are characterized by higher reproducibility than the contact measurements. The low reproducibility of contact measurements may be connected with the inaccuracy of the selected coordinate measuring machine and the measuring probe, the measurement parameters and environmental conditions in the laboratory where the coordinate measuring machine is located. Moreover, the paper presents the possible application of results of conducted investigations. The results of non-contact measurements can be used in the simulation studies of grinding processes. The simulations may reduce the costs of machining processes.

  20. Processes linked to contact changes in adoptive kinship networks.

    Science.gov (United States)

    Dunbar, Nora; van Dulmen, Manfred H M; Ayers-Lopez, Susan; Berge, Jerica M; Christian, Cinda; Gossman, Ginger; Henney, M Susan M; Mendenhall, Tai J; Grotevant, Harold D; McRoy, Ruth G

    2006-12-01

    The purpose of this study was to reveal underlying processes in adoptive kinship networks that experienced increases or decreases in levels of openness during the child's adolescent years. Intensive case study analyses were conducted for 8 adoptive kinship networks (each including an adoptive mother, adoptive father, adopted adolescent, and birth mother), half of whom had experienced an increase in openness from indirect (mediated) to direct (fully disclosed) contact and half of whom had ceased indirect contact between Waves 1 and 2 of a longitudinal study. Adoptive mothers tended to be more involved in contact with the birth mother than were adoptive fathers or adopted adolescents. Members of adoptive kinship networks in which a decrease in level of contact took place had incongruent perspectives about who initiated the stop in contact and why the stop took place. Birth mothers were less satisfied with their degree of contact than were adoptive parents. Adults' satisfaction with contact was related to feelings of control over type and amount of interactions and permeability of family boundaries. In all adoptive kinship networks, responsibility for contact had shifted toward the adopted adolescent regardless of whether the adolescent was aware of this change in responsibility.

  1. Wildlife contact analysis: Emerging methods, questions, and challenges

    Science.gov (United States)

    Cross, Paul C.; Creech, Tyler G.; Ebinger, Michael R.; Heisey, Dennis M.; Irvine, Kathryn M.; Creel, Scott

    2012-01-01

    Recent technological advances, such as proximity loggers, allow researchers to collect complete interaction histories, day and night, among sampled individuals over several months to years. Social network analyses are an obvious approach to analyzing interaction data because of their flexibility for fitting many different social structures as well as the ability to assess both direct contacts and indirect associations via intermediaries. For many network properties, however, it is not clear whether estimates based upon a sample of the network are reflective of the entire network. In wildlife applications, networks may be poorly sampled and boundary effects will be common. We present an alternative approach that utilizes a hierarchical modeling framework to assess the individual, dyadic, and environmental factors contributing to variation in the interaction rates and allows us to estimate the underlying process variation in each. In a disease control context, this approach will allow managers to focus efforts on those types of individuals and environments that contribute the most toward super-spreading events. We account for the sampling distribution of proximity loggers and the non-independence of contacts among groups by only using contact data within a group during days when the group membership of proximity loggers was known. This allows us to separate the two mechanisms responsible for a pair not contacting one another: they were not in the same group or they were in the same group but did not come within the specified contact distance. We illustrate our approach with an example dataset of female elk from northwestern Wyoming and conclude with a number of important future research directions.

  2. Eye Contact Is Crucial for Referential Communication in Pet Dogs.

    Science.gov (United States)

    Savalli, Carine; Resende, Briseida; Gaunet, Florence

    2016-01-01

    Dogs discriminate human direction of attention cues, such as body, gaze, head and eye orientation, in several circumstances. Eye contact particularly seems to provide information on human readiness to communicate; when there is such an ostensive cue, dogs tend to follow human communicative gestures more often. However, little is known about how such cues influence the production of communicative signals (e.g. gaze alternation and sustained gaze) in dogs. In the current study, in order to get an unreachable food, dogs needed to communicate with their owners in several conditions that differ according to the direction of owners' visual cues, namely gaze, head, eyes, and availability to make eye contact. Results provided evidence that pet dogs did not rely on details of owners' direction of visual attention. Instead, they relied on the whole combination of visual cues and especially on the owners' availability to make eye contact. Dogs increased visual communicative behaviors when they established eye contact with their owners, a different strategy compared to apes and baboons, that intensify vocalizations and gestures when human is not visually attending. The difference in strategy is possibly due to distinct status: domesticated vs wild. Results are discussed taking into account the ecological relevance of the task since pet dogs live in human environment and face similar situations on a daily basis during their lives.

  3. Leukotriene B4—leukotriene B4 receptor axis promotes oxazolone-induced contact dermatitis by directing skin homing of neutrophils and CD8+ T cells

    Science.gov (United States)

    Lv, Jiaoyan; Zou, Linlin; Zhao, Lina; Yang, Wei; Xiong, Yingluo; Li, Bingji; He, Rui

    2015-01-01

    Leukotriene B4 (LTB4) is a lipid mediator that is rapidly generated in inflammatory sites, and its functional receptor, BLT1, is mostly expressed on immune cells. Contact dermatitis is a common inflammatory skin disease characterized by skin oedema and abundant inflammatory infiltrates, primarily including neutrophils and CD8+ T cells. The role of the LTB4–BLT1 axis in contact dermatitis remains largely unknown. In this study, we found up-regulated gene expression of 5-lipoxygenase and leukotriene A4 hydrolase, two critical enzymes for LTB4 synthesis, BLT1 and elevated LTB4 levels in skin lesions of oxazolone (OXA)-induced contact dermatitis. BLT1 deficiency or blockade of LTB4 and BLT1 by the antagonists, bestatin and U-75302, respectively, in the elicitation phase caused significant decreases in ear swelling and skin-infiltrating neutrophils and CD8+ T cells, which was accompanied by significantly reduced skin expression of CXCL1, CXCL2, interferon-γ and interleukin-1β. Furthermore, neutrophil depletion during the elicitation phase of OXA-induced contact dermatitis also caused significant decreases in ear swelling and CD8+ T-cell infiltration accompanied by significantly decreased LTB4 synthesis and gene expression of CXCL2, interferon-γ and interleukin-1β. Importantly, subcutaneous injection of exogenous LTB4 restored the skin infiltration of CD8+ T cells in neutrophil-depleted mice following OXA challenge. Collectively, our results demonstrate that the LTB4–BLT1 axis contributes to OXA-induced contact dermatitis by mediating skin recruitment of neutrophils, which are a major source of LTB4 that sequentially direct CD8+ T-cell homing to OXA-challenged skin. Hence, LTB4 and BLT1 could be potential therapeutic targets for the treatment of contact dermatitis. PMID:25959240

  4. 5 CFR 330.504 - Special restrictions after appointment under Part-time Direct Hire Program.

    Science.gov (United States)

    2010-01-01

    ... under Part-time Direct Hire Program. 330.504 Section 330.504 Administrative Personnel OFFICE OF... To Protect Competitive Principles § 330.504 Special restrictions after appointment under Part-time Direct Hire Program. (a) A person hired under the Part-time Direct Hire Program may not be changed to...

  5. Communicating one's local address and emergency contact details

    CERN Multimedia

    Information Technology Department, AIS (Administrative Information Services) Group; Human Resources Department, SPS (Services, Procedures and Social) Group

    2007-01-01

    As part of the ongoing simplification of procedures and rationalisation of administrative processes, the IT, PH (Users Office) and HR Departments have developed two new EDH forms for communicating or updating one's local address and emergency contact details. This is the first time that the forms relating to an official HR procedure can be accessed on a self-service basis and directly updated by the members of personnel themselves. The information recorded remains confidential and may only be accessed by the authorised administrative services and the emergency services. Local address: Members of the personnel must declare any change in their local address (Art. R V 1.38 of the Staff Regulations). This declaration is henceforth made by directly filling out the EDH document indicated below, and without requiring any other spontaneous formality vis-à-vis the department secretariat or the Users Office. It is also possible for any member of the personnel to check whether the local address in the Organizati...

  6. Toward full-chip prediction of yield-limiting contact patterning failure: correlation of simulated image parameters to advanced contact metrology metrics

    Science.gov (United States)

    Sturtevant, John L.; Chou, Dyiann

    2006-03-01

    Electrical failure due to incomplete contacts or vias has arisen as one of the primary modes of yield loss for 130 nm and below designs in manufacturing. Such failures are generally understood to arise from both random and systematic sources. The addition of redundant vias, where possible, has long been an accepted DFM practice for mitigating the impact of random defects. Incomplete vias are often characterized by having a diameter near the target dimension but a depth of less than 100% of target. As such, it is a difficult problem to diagnose and debug in-line, since bright and dark field optical inspection systems cannot typically distinguish between a closed, partially open and fully open contact. Advanced metrology systems have emerged in recent years to meet this challenge, but no perfect manufacturing solution has yet been identified for full field verification of all contacts. Voltage Contrast (VC) SEM metrology biases the wafer to directly measure electrical conductivity after fill / polish, and can therefore easily discern a lack of electrical connection to the underlying conductor caused by incomplete photo, etch, or fill processing. While an entire wafer can in principal be VC scanned, throughput limitations dictate very sparse sampling in manufacturing. SEM profile grading (PG) leverages the rich content of the secondary electron waveform to decipher information about the bottom of the contact. Several authors have demonstrated an excellent response of the Profile Grade to intentional defocus vectors. However, the SEM can only target discreet or single digit groupings of contacts, and therefore requires intelligent guidance to identify those contacts which are most prone to failure, enabling protection of the fab WIP. An a-priori knowledge of which specific contacts in a layout are most likely to fail would prove very useful for proactive inspection in manufacturing. Model based pre-manufacturing verification allows for such knowledge to be communicated

  7. Field test of two high-pressure direct-contact downhole steam generators. Volume II. Oxygen/diesel system

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, J.B.

    1983-07-01

    A field test of an oxygen/diesel fuel, direct contact steam generator has been completed. The field test, which was a part of Project DEEP STEAM and was sponsored by the US Department of Energy, involved the thermal stimulation of a well pattern in the Tar Zone of the Wilmington Oil Field. The activity was carried out in cooperation with the City of Long Beach and the Long Beach Oil Development Company. The steam generator was operated at ground level, with the steam and combustion products delivered to the reservoir through 2022 feet of calcium-silicate insulated tubing. The objectives of the test included demonstrations of safety, operational ease, reliability and lifetime; investigations of reservoir response, environmental impact, and economics; and comparison of those points with a second generator that used air rather than oxygen. The test was extensively instrumented to provide the required data. Excluding interruptions not attributable to the oxygen/diesel system, steam was injected 78% of the time. System lifetime was limited by the combustor, which required some parts replacement every 2 to 3 weeks. For the conditions of this particular test, the use of trucked-in LOX resulted in liess expense than did the production of the equivalent amount of high pressure air using on site compressors. No statistically significant production change in the eight-acre oxygen system well pattern occurred during the test, nor were any adverse effects on the reservoir character detected. Gas analyses during the field test showed very low levels of SOX (less than or equal to 1 ppM) in the generator gaseous effluent. The SOX and NOX data did not permit any conclusion to be drawn regarding reservoir scrubbing. Appreciable levels of CO (less than or equal to 5%) were measured at the generator, and in this case produced-gas analyses showed evidence of significant gas scrubbing. 64 figures, 10 tables.

  8. Ocular discomfort responses after short periods of contact lens wear.

    Science.gov (United States)

    Papas, Eric; Tilia, Daniel; McNally, John; de la Jara, Percy Lazon

    2015-06-01

    To investigate if contact lens-related discomfort is a function of the time of day at which lenses are worn. This was a randomized, crossover, open-label clinical trial where subjective responses, with and without contact lenses, were assessed every 2 hours during five stages (A to E). Each stage began at the time when subjects would normally have inserted their contact lenses (T0). During stage A, no lenses were worn, whereas in stage B, lenses were worn continuously for 12 hours. In stages C to E, lenses were worn for only 4 hours. Contact lenses were inserted at T0 for stage C, but for stages D and E, lenses were not inserted until T0 + 4 and T0 + 8 hours, respectively. Mixed linear models were used for statistical analysis. In the absence of contact lenses, ocular comfort and dryness remained reasonably constant throughout the observation period. Ocular comfort and dryness decreased during 12 hours of continuous lens wear and became significantly worse from the 8-hour time onward compared with insertion (p 0.05) to the first 4 hours of continuous contact lens wear. Comparing the scores of each of these stages with the no-lens response at the corresponding time showed no significant differences for comfort (p > 0.23) or dryness (p > 0.37). Short periods of wear can be experienced at any time of day without significant change in ocular discomfort and dryness. This suggests that subjective responses at the end of the day are determined by the length of time lenses are in contact with the eye, rather than the time of day at which lenses are worn.

  9. Leaching of boron, arsenic and selenium from sedimentary rocks: I. Effects of contact time, mixing speed and liquid-to-solid ratio

    Energy Technology Data Exchange (ETDEWEB)

    Tabelin, Carlito Baltazar, E-mail: carlito@trans-er.eng.hokudai.ac.jp [Laboratory of Soil Environment Engineering, Faculty of Engineering, Hokkaido University, Sapporo (Japan); Hashimoto, Ayaka, E-mail: a.hashimoto@diaconsult.co.jp [DIA Consultants Co. Ltd., Sapporo (Japan); Igarashi, Toshifumi, E-mail: tosifumi@eng.hokudai.ac.jp [Laboratory of Groundwater and Mass Transport, Faculty of Engineering, Hokkaido University, Sapporo (Japan); Yoneda, Tetsuro, E-mail: yonet@eng.hokudai.ac.jp [Laboratory of Soil Environment Engineering, Faculty of Engineering, Hokkaido University, Sapporo (Japan)

    2014-02-01

    Sedimentary rocks of marine origin excavated in tunnel projects were recently identified as potentially hazardous because they could release significant amounts of toxic trace elements when exposed to the environment. This study investigated the leaching characteristics of B, As, Se and the major coexisting ions under various conditions to identify the factors and processes controlling their evolution in the leachate. In addition, we evaluated whether the parameters of the currently used leachability test for excavated rocks were adequate. Although the leachabilities of B, As and Se similarly increased at longer contact times, only those of B and As were influenced by the mixing speed and/or liquid-to-solid ratio (L/S). The majority of trace elements dissolved in the leachate originated from the dissolution of soluble salts formed from seawater of the Cretaceous trapped during the formation of the sedimentary rocks. Moreover, the alkaline pH of the leachates could be attributed to the simultaneous dissolutions at varying degrees of the mineral components of the rocks as well as the precipitation of clay minerals. In the leaching test of excavated rocks for regulatory purposes, the best values of contact time and mixing speed should represent conditions of the highest trace element extractabilities, which in this study were found at longer contact times ( > 48 h) and the fastest mixing speed (200 rpm). The most appropriate L/S for the leaching test is 10 because it was around this L/S that the extractabilities and leaching concentrations of the trace elements were simultaneously observed at their highest values. - Highlights: • B, As and Se leaching increased with time reaching equilibrium after ca. 48 h. • Effect of L/S on B and As leaching was strong but not that much on Se. • All leachates were alkaline regardless of the contact time, mixing speed and L/S. • Na{sup +}–SO{sub 4}{sup 2−} and Na{sup +}–HCO{sub 3}{sup −} type leachates were produced

  10. Contact Patterns in a High School: A Comparison between Data Collected Using Wearable Sensors, Contact Diaries and Friendship Surveys.

    Directory of Open Access Journals (Sweden)

    Rossana Mastrandrea

    Full Text Available Given their importance in shaping social networks and determining how information or transmissible diseases propagate in a population, interactions between individuals are the subject of many data collection efforts. To this aim, different methods are commonly used, ranging from diaries and surveys to decentralised infrastructures based on wearable sensors. These methods have each advantages and limitations but are rarely compared in a given setting. Moreover, as surveys targeting friendship relations might suffer less from memory biases than contact diaries, it is interesting to explore how actual contact patterns occurring in day-to-day life compare with friendship relations and with online social links. Here we make progresses in these directions by leveraging data collected in a French high school and concerning (i face-to-face contacts measured by two concurrent methods, namely wearable sensors and contact diaries, (ii self-reported friendship surveys, and (iii online social links. We compare the resulting data sets and find that most short contacts are not reported in diaries while long contacts have a large reporting probability, and that the durations of contacts tend to be overestimated in the diaries. Moreover, measured contacts corresponding to reported friendship can have durations of any length but all long contacts do correspond to a reported friendship. On the contrary, online links that are not also reported in the friendship survey correspond to short face-to-face contacts, highlighting the difference of nature between reported friendships and online links. Diaries and surveys suffer moreover from a low sampling rate, as many students did not fill them, showing that the sensor-based platform had a higher acceptability. We also show that, despite the biases of diaries and surveys, the overall structure of the contact network, as quantified by the mixing patterns between classes, is correctly captured by both networks of self

  11. Contact Patterns in a High School: A Comparison between Data Collected Using Wearable Sensors, Contact Diaries and Friendship Surveys.

    Science.gov (United States)

    Mastrandrea, Rossana; Fournet, Julie; Barrat, Alain

    2015-01-01

    Given their importance in shaping social networks and determining how information or transmissible diseases propagate in a population, interactions between individuals are the subject of many data collection efforts. To this aim, different methods are commonly used, ranging from diaries and surveys to decentralised infrastructures based on wearable sensors. These methods have each advantages and limitations but are rarely compared in a given setting. Moreover, as surveys targeting friendship relations might suffer less from memory biases than contact diaries, it is interesting to explore how actual contact patterns occurring in day-to-day life compare with friendship relations and with online social links. Here we make progresses in these directions by leveraging data collected in a French high school and concerning (i) face-to-face contacts measured by two concurrent methods, namely wearable sensors and contact diaries, (ii) self-reported friendship surveys, and (iii) online social links. We compare the resulting data sets and find that most short contacts are not reported in diaries while long contacts have a large reporting probability, and that the durations of contacts tend to be overestimated in the diaries. Moreover, measured contacts corresponding to reported friendship can have durations of any length but all long contacts do correspond to a reported friendship. On the contrary, online links that are not also reported in the friendship survey correspond to short face-to-face contacts, highlighting the difference of nature between reported friendships and online links. Diaries and surveys suffer moreover from a low sampling rate, as many students did not fill them, showing that the sensor-based platform had a higher acceptability. We also show that, despite the biases of diaries and surveys, the overall structure of the contact network, as quantified by the mixing patterns between classes, is correctly captured by both networks of self-reported contacts and

  12. Contact compliance effects in the frictional response of bioinspired fibrillar adhesives

    Science.gov (United States)

    Piccardo, Marco; Chateauminois, Antoine; Fretigny, Christian; Pugno, Nicola M.; Sitti, Metin

    2013-01-01

    The shear failure and friction mechanisms of bioinspired adhesives consisting of elastomer arrays of microfibres terminated by mushroom-shaped tips are investigated in contact with a rigid lens. In order to reveal the interplay between the vertical and lateral loading directions, experiments are carried out using a custom friction set-up in which normal stiffness can be made either high or low when compared with the stiffness of the contact between the fibrillar adhesive and the lens. Using in situ contact imaging, the shear failure of the adhesive is found to involve two successive mechanisms: (i) cavitation and peeling at the contact interface between the mushroom-shaped fibre tip endings and the lens; and (ii) side re-adhesion of the fibre's stem to the lens. The extent of these mechanisms and their implications regarding static friction forces is found to depend on the crosstalk between the normal and lateral loading directions that can result in contact instabilities associated with fibre buckling. In addition, the effects of the viscoelastic behaviour of the polyurethane material on the rate dependence of the shear response of the adhesive are accounted for. PMID:23554349

  13. Non-contact evaluation of milk-based products using air-coupled ultrasound

    Science.gov (United States)

    Meyer, S.; Hindle, S. A.; Sandoz, J.-P.; Gan, T. H.; Hutchins, D. A.

    2006-07-01

    An air-coupled ultrasonic technique has been developed and used to detect physicochemical changes of liquid beverages within a glass container. This made use of two wide-bandwidth capacitive transducers, combined with pulse-compression techniques. The use of a glass container to house samples enabled visual inspection, helping to verify the results of some of the ultrasonic measurements. The non-contact pulse-compression system was used to evaluate agglomeration processes in milk-based products. It is shown that the amplitude of the signal varied with time after the samples had been treated with lactic acid, thus promoting sample destabilization. Non-contact imaging was also performed to follow destabilization of samples by scanning in various directions across the container. The obtained ultrasonic images were also compared to those from a digital camera. Coagulation with glucono-delta-lactone of skim milk poured into this container could be monitored within a precision of a pH of 0.15. This rapid, non-contact and non-destructive technique has shown itself to be a feasible method for investigating the quality of milk-based beverages, and possibly other food products.

  14. Technologies for hydrogen production based on direct contact of gaseous hydrocarbons and evaporated water with Molten Pb or Pb-Bi

    International Nuclear Information System (INIS)

    Gulevich, A. V.; Martynov, P. N.; Gulevsky, V. A.; Ulyanov, V. V.

    2007-01-01

    Results of studies intended for the substantiation of a new energy-saving and safe technology for low cost hydrogen production have been presented. The technology's basis is direct mixing of water and (or) gaseous hydrocarbons with heavy liquid metal coolants (HLMC) Pb or Pb-Bi. Preliminary research has been done on thermal dynamics and kinetics of the processes taking place in the interaction of HLMC with hydrocarbon-containing gases. It has been shown as a result that water and gaseous hydrocarbons interact with molten Pb and Pb-Bi relatively quietly in chemical aspect (without ignition and explosions). Therefore, (and taking into account the thermal physics, physical and chemical properties of HLMC such as low pressure of saturated vapor of Pb and Pb- Bi in enhanced temperatures, their good heat conductivity and heat capacity, low viscosity, etc.) heat transfer is possible from the molten metal to water and hydrocarbons without heat transferring partitions (that is, by direct contact of the working media). Devices to implement this method of heating liquid and gaseous media provide essential advantages: - A simple design; - None heat-transferring surfaces subject to corrosion, contamination, thermal fatigue, vibration impacts; - A high effectiveness owing to a larger heat exchanging surface per volume unit; - A small hydraulic resistance. The possibility and effectiveness of heating various gaseous and liquid media in their direct contact with molten Pb and Pb-Bi has been substantiated convincingly by experimental results at IPPE. Besides, the following processes of hydrogen-containing media conversion have been proved feasible thereby. 1. Water decomposition into hydrogen and oxygen. The process can develop at temperatures of 400-1000 degree C. It is necessary to provide constant removal of oxygen from the reaction zone and maintain a minimum possible content of chemically active oxygen in the melt. 2. Pyrolytic decomposition of hydrocarbons into carbon and

  15. Current neurosurgical trainees' perception of the European Working Time Directive and shift work.

    Science.gov (United States)

    Tait, M J; Fellows, G A; Pushpananthan, S; Sergides, Y; Papadopoulos, M C; Bell, B A

    2008-02-01

    The introduction of the shift system in response to the European Working Time Directive has had an enormous impact on the running of neurosurgical units in the UK. This study seeks to establish what provisions are currently in place for out of hours cover and what has been the effect of the introduction of shifts in three main areas: patient safety, training and 'work/life balance'. The on-call registrar at each UK neurosurgical unit was contacted by telephone. Data regarding current emergency provision were sought. Registrars who had worked both on-calls and the shift system during their career as a neurosurgical registrar were asked to make a comparison. Data were collected from all 33 UK units. Twenty-two still use a traditional 24-h on-call system. Twenty-one on-call rotas were classed as non-resident although 12/21 of those officially on non-resident rotas were in fact resident whilst on call. Twenty-two registrars had worked both systems as a neurosurgical registrar. Twenty-one (95.45%) felt that traditional on-calls gave better clinical exposure. Twenty-one (95.45%) felt that on-calls allowed the provision of better patient care. Nineteen (86.36%) felt that on-calls were safer. Thirteen (59.09%) reported that they were more tired when doing shift work than on-calls. Fourteen (63.63%) found that the on-call system gives more useful spare time and more time to deal with family commitments. Current neurosurgery registrars feel the shift system is less safe, harmful to training and worse in terms of work/life balance. More than one-third of units are claiming to have non-resident on-call systems in order to appear compliant with EWTD when registrars are in fact resident.

  16. True random bit generators based on current time series of contact glow discharge electrolysis

    Science.gov (United States)

    Rojas, Andrea Espinel; Allagui, Anis; Elwakil, Ahmed S.; Alawadhi, Hussain

    2018-05-01

    Random bit generators (RBGs) in today's digital information and communication systems employ a high rate physical entropy sources such as electronic, photonic, or thermal time series signals. However, the proper functioning of such physical systems is bound by specific constrains that make them in some cases weak and susceptible to external attacks. In this study, we show that the electrical current time series of contact glow discharge electrolysis, which is a dc voltage-powered micro-plasma in liquids, can be used for generating random bit sequences in a wide range of high dc voltages. The current signal is quantized into a binary stream by first using a simple moving average function which makes the distribution centered around zero, and then applying logical operations which enables the binarized data to pass all tests in industry-standard randomness test suite by the National Institute of Standard Technology. Furthermore, the robustness of this RBG against power supply attacks has been examined and verified.

  17. Terahertz time domain interferometry of a SIS tunnel junction and a quantum point contact

    Energy Technology Data Exchange (ETDEWEB)

    Karadi, Chandu [Univ. of California, Berkeley, CA (United States). Dept. of Physics

    1995-09-01

    The author has applied the Terahertz Time Domain Interferometric (THz-TDI) technique to probe the ultrafast dynamic response of a Superconducting-Insulating-Superconducting (SIS) tunnel junction and a Quantum Point Contact (QPC). The THz-TDI technique involves monitoring changes in the dc current induced by interfering two picosecond electrical pulses on the junction as a function of time delay between them. Measurements of the response of the Nb/AlOxNb SIS tunnel junction from 75--200 GHz are in full agreement with the linear theory for photon-assisted tunneling. Likewise, measurements of the induced current in a QPC as a function of source-drain voltage, gate voltage, frequency, and magnetic field also show strong evidence for photon-assisted transport. These experiments together demonstrate the general applicability of the THz-TDI technique to the characterization of the dynamic response of any micron or nanometer scale device that exhibits a non-linear I-V characteristic.

  18. Terahertz time domain interferometry of a SIS tunnel junction and a quantum point contact

    International Nuclear Information System (INIS)

    Karadi, C.; Lawrence Berkeley Lab., CA

    1995-09-01

    The author has applied the Terahertz Time Domain Interferometric (THz-TDI) technique to probe the ultrafast dynamic response of a Superconducting-Insulating-Superconducting (SIS) tunnel junction and a Quantum Point Contact (QPC). The THz-TDI technique involves monitoring changes in the dc current induced by interfering two picosecond electrical pulses on the junction as a function of time delay between them. Measurements of the response of the Nb/AlO x /Nb SIS tunnel junction from 75--200 GHz are in full agreement with the linear theory for photon-assisted tunneling. Likewise, measurements of the induced current in a QPC as a function of source-drain voltage, gate voltage, frequency, and magnetic field also show strong evidence for photon-assisted transport. These experiments together demonstrate the general applicability of the THz-TDI technique to the characterization of the dynamic response of any micron or nanometer scale device that exhibits a non-linear I-V characteristic. 133 refs., 49 figs

  19. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ... a laser pointer several times, according to a report published this month in the New England Journal ...

  20. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Halloween or any time of year, follow these guidelines: Get an eye exam from a licensed eye ... available in Spanish . Follow The Academy Professionals: Education Guidelines News Multimedia Public & Patients: Contact Us About the ...

  1. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Peligros asociados con los lentes de contacto de color Sep. 26, 2013 It started as an impulsive ... Halloween is a popular time for people to use colored contact lenses to enhance their costumes. From ...

  2. Force Trends and Pulsatility for Catheter Contact Identification in Intracardiac Electrograms during Arrhythmia Ablation.

    Science.gov (United States)

    Rivas-Lalaleo, David; Muñoz-Romero, Sergio; Huerta, Mónica; Erazo-Rodas, Mayra; Sánchez-Muñoz, Juan José; Rojo-Álvarez, José Luis; García-Alberola, Arcadi

    2018-05-02

    The intracardiac electrical activation maps are commonly used as a guide in the ablation of cardiac arrhythmias. The use of catheters with force sensors has been proposed in order to know if the electrode is in contact with the tissue during the registration of intracardiac electrograms (EGM). Although threshold criteria on force signals are often used to determine the catheter contact, this may be a limited criterion due to the complexity of the heart dynamics and cardiac vorticity. The present paper is devoted to determining the criteria and force signal profiles that guarantee the contact of the electrode with the tissue. In this study, we analyzed 1391 force signals and their associated EGM recorded during 2 and 8 s, respectively, in 17 patients (82 ± 60 points per patient). We aimed to establish a contact pattern by first visually examining and classifying the signals, according to their likely-contact joint profile and following the suggestions from experts in the doubtful cases. First, we used Principal Component Analysis to scrutinize the force signal dynamics by analyzing the main eigen-directions, first globally and then grouped according to the certainty of their tissue-catheter contact. Second, we used two different linear classifiers (Fisher discriminant and support vector machines) to identify the most relevant components of the previous signal models. We obtained three main types of eigenvectors, namely, pulsatile relevant, non-pulsatile relevant, and irrelevant components. The classifiers reached a moderate to sufficient discrimination capacity (areas under the curve between 0.84 and 0.95 depending on the contact certainty and on the classifier), which allowed us to analyze the relevant properties in the force signals. We conclude that the catheter-tissue contact profiles in force recordings are complex and do not depend only on the signal intensity being above a threshold at a single time instant, but also on time pulsatility and trends. These

  3. Patterned Liquid Metal Contacts for Printed Carbon Nanotube Transistors.

    Science.gov (United States)

    Andrews, Joseph B; Mondal, Kunal; Neumann, Taylor V; Cardenas, Jorge A; Wang, Justin; Parekh, Dishit P; Lin, Yiliang; Ballentine, Peter; Dickey, Michael D; Franklin, Aaron D

    2018-05-14

    Flexible and stretchable electronics are poised to enable many applications that cannot be realized with traditional, rigid devices. One of the most promising options for low-cost stretchable transistors are printed carbon nanotubes (CNTs). However, a major limiting factor in stretchable CNT devices is the lack of a stable and versatile contact material that forms both the interconnects and contact electrodes. In this work, we introduce the use of eutectic gallium-indium (EGaIn) liquid metal for electrical contacts to printed CNT channels. We analyze thin-film transistors (TFTs) fabricated using two different liquid metal deposition techniques-vacuum-filling polydimethylsiloxane (PDMS) microchannel structures and direct-writing liquid metals on the CNTs. The highest performing CNT-TFT was realized using vacuum-filled microchannel deposition with an in situ annealing temperature of 150 °C. This device exhibited an on/off ratio of more than 10 4 and on-currents as high as 150 μA/mm-metrics that are on par with other printed CNT-TFTs. Additionally, we observed that at room temperature the contact resistances of the vacuum-filled microchannel structures were 50% lower than those of the direct-write structures, likely due to the poor adhesion between the materials observed during the direct-writing process. The insights gained in this study show that stretchable electronics can be realized using low-cost and solely solution processing techniques. Furthermore, we demonstrate methods that can be used to electrically characterize semiconducting materials as transistors without requiring elevated temperatures or cleanroom processes.

  4. Conjugate gradient based projection - A new explicit methodology for frictional contact

    Science.gov (United States)

    Tamma, Kumar K.; Li, Maocheng; Sha, Desong

    1993-01-01

    With special attention towards the applicability to parallel computation or vectorization, a new and effective explicit approach for linear complementary formulations involving a conjugate gradient based projection methodology is proposed in this study for contact problems with Coulomb friction. The overall objectives are focussed towards providing an explicit methodology of computation for the complete contact problem with friction. In this regard, the primary idea for solving the linear complementary formulations stems from an established search direction which is projected to a feasible region determined by the non-negative constraint condition; this direction is then applied to the Fletcher-Reeves conjugate gradient method resulting in a powerful explicit methodology which possesses high accuracy, excellent convergence characteristics, fast computational speed and is relatively simple to implement for contact problems involving Coulomb friction.

  5. On the Influence of Clearance in Orthotropic Disc-Pin Contacts

    DEFF Research Database (Denmark)

    Pedersen, Pauli

    2007-01-01

    , an orthotropic disc-pin contact problem. The most simple solutions are named Hertz solutions (from 1882), and we use one of these solutions for comparison with finite element results. As a function of the total contact force we find (inversely) the size of the contact area, the distribution of the contact......Solutions to contact problems are important in mechanical as well as in civil engineering, and even for the most simple problems there is still a need for research results. In the present paper we use an alternative super element procedure to solve directly, without iteration and incrementation...... pressure, and the contact compliance. In models of finite size the compliance depends on the flexibility of the total model, including the boundary condition of the model, and therefore disagreement with the locally based analytical models is expected. The examples of an earlier paper were restricted...

  6. Less-structured time in children's daily lives predicts self-directed executive functioning.

    Science.gov (United States)

    Barker, Jane E; Semenov, Andrei D; Michaelson, Laura; Provan, Lindsay S; Snyder, Hannah R; Munakata, Yuko

    2014-01-01

    Executive functions (EFs) in childhood predict important life outcomes. Thus, there is great interest in attempts to improve EFs early in life. Many interventions are led by trained adults, including structured training activities in the lab, and less-structured activities implemented in schools. Such programs have yielded gains in children's externally-driven executive functioning, where they are instructed on what goal-directed actions to carry out and when. However, it is less clear how children's experiences relate to their development of self-directed executive functioning, where they must determine on their own what goal-directed actions to carry out and when. We hypothesized that time spent in less-structured activities would give children opportunities to practice self-directed executive functioning, and lead to benefits. To investigate this possibility, we collected information from parents about their 6-7 year-old children's daily, annual, and typical schedules. We categorized children's activities as "structured" or "less-structured" based on categorization schemes from prior studies on child leisure time use. We assessed children's self-directed executive functioning using a well-established verbal fluency task, in which children generate members of a category and can decide on their own when to switch from one subcategory to another. The more time that children spent in less-structured activities, the better their self-directed executive functioning. The opposite was true of structured activities, which predicted poorer self-directed executive functioning. These relationships were robust (holding across increasingly strict classifications of structured and less-structured time) and specific (time use did not predict externally-driven executive functioning). We discuss implications, caveats, and ways in which potential interpretations can be distinguished in future work, to advance an understanding of this fundamental aspect of growing up.

  7. Relationship Between the Electroglottographic Signal and Vocal Fold Contact Area.

    Science.gov (United States)

    Hampala, Vít; Garcia, Maxime; Švec, Jan G; Scherer, Ronald C; Herbst, Christian T

    2016-03-01

    Electroglottography (EGG) is a widely used noninvasive method that purports to measure changes in relative vocal fold contact area (VFCA) during phonation. Despite its broad application, the putative direct relation between the EGG waveform and VFCA has to date only been formally tested in a single study, suggesting an approximately linear relationship. However, in that study, flow-induced vocal fold (VF) vibration was not investigated. A rigorous empirical evaluation of EGG as a measure of VFCA under proper physiological conditions is therefore still needed. Three red deer larynges were phonated in an excised hemilarynx preparation using a conducting glass plate. The time-varying contact between the VF and the glass plate was assessed by high-speed video recordings at 6000 fps, synchronized to the EGG signal. The average differences between the normalized [0, 1] VFCA and EGG waveforms for the three larynges were 0.180 (±0.156), 0.075 (±0.115), and 0.168 (±0.184) in the contacting phase and 0.159 (±0.112), -0.003 (±0.029), and 0.004 (±0.032) in the decontacting phase. Overall, there was a better agreement between VFCA and the EGG waveform in the decontacting phase than in the contacting phase. Disagreements may be caused by nonuniform tissue conductance properties, electrode placement, and electroglottograph hardware circuitry. Pending further research, the EGG waveform may be a reasonable first approximation to change in medial contact area between the VFs during phonation. However, any quantitative and statistical data derived from EGG should be interpreted cautiously, allowing for potential deviations from true VFCA. Copyright © 2016 The Auhors. Published by Elsevier Inc. All rights reserved.

  8. Performance investigation of a solar-assisted direct contact membrane distillation system

    KAUST Repository

    Kim, Youngdeuk

    2013-01-01

    This paper presents a solar-assisted direct contact membrane distillation (DCMD) system with novel energy recovery concepts for a continuous 24-h-a-day operation. A temperature modulating scheme is introduced to the solar-thermal system that supplies feed seawater to the DCMD modules. This scheme attenuates extreme temperature fluctuations of the feed water by storing the collected energy during solar-peak hours and reutilizing it throughout the day. Thus, the energy savings is realized yet the feed seawater temperature is maintained within the desired range. Additionally, the system employs heat recovery from the permeate and brine streams to the feed seawater. The simulations for such a system with a shell-and-tube type DCMD modules are carried out to examine the spatial property variations and the sensitivity of system performance (i.e., transmembrane pressure, permeate flux and performance ratio) to the operating conditions (inlet temperature and flow rate) and the fiber dimensions (fiber length and packing density). It is found that there are trade-offs between mean permeate flux and performance ratio with respect to permeate inlet temperature and flow rate and between total distillate production and performance ratio with respect to packing density. For the solar-assisted DCMD system having evacuated-tube collectors of 3360m2 with 160m3 seawater storage tanks and 50 DCMD modules, the annual solar fraction and the collector efficiency are found to be 77% and 53%, respectively, whilst the overall permeate production capacity is 31m3/day. The overall specific thermal energy consumption of the DCMD system with heat recovery is found to be 436kWh/m3 and it is about 43% lower as compared to the system without heat recovery. It is observed that the specific thermal energy consumption decreases significantly by 55% with increased collector area from 1983m2 to 3360m2 whereas the specific electrical energy consumption increases slightly by 16%. © 2012 Elsevier B.V.

  9. Rough viscoelastic sliding contact: Theory and experiments

    Science.gov (United States)

    Carbone, G.; Putignano, C.

    2014-03-01

    In this paper, we show how the numerical theory introduced by the authors [Carbone and Putignano, J. Mech. Phys. Solids 61, 1822 (2013), 10.1016/j.jmps.2013.03.005] can be effectively employed to study the contact between viscoelastic rough solids. The huge numerical complexity is successfully faced up by employing the adaptive nonuniform mesh developed by the authors in Putignano et al. [J. Mech. Phys. Solids 60, 973 (2012), 10.1016/j.jmps.2012.01.006]. Results mark the importance of accounting for viscoelastic effects to correctly simulate the sliding rough contact. In detail, attention is, first, paid to evaluate the viscoelastic dissipation, i.e., the viscoelastic friction. Fixed the sliding speed and the normal load, friction is completely determined. Furthermore, since the methodology employed in the work allows to study contact between real materials, a comparison between experimental outcomes and numerical prediction in terms of viscoelastic friction is shown. The good agreement seems to validate—at least partially—the presented methodology. Finally, it is shown that viscoelasticity entails not only the dissipative effects previously outlined, but is also strictly related to the anisotropy of the contact solution. Indeed, a marked anisotropy is present in the contact region, which results stretched in the direction perpendicular to the sliding speed. In the paper, the anisotropy of the deformed surface and of the contact area is investigated and quantified.

  10. Direct-contact condensers for open-cycle OTEC applications: Model validation with fresh water experiments for structured packings

    Energy Technology Data Exchange (ETDEWEB)

    Bharathan, D.; Parsons, B.K.; Althof, J.A.

    1988-10-01

    The objective of the reported work was to develop analytical methods for evaluating the design and performance of advanced high-performance heat exchangers for use in open-cycle thermal energy conversion (OC-OTEC) systems. This report describes the progress made on validating a one-dimensional, steady-state analytical computer of fresh water experiments. The condenser model represents the state of the art in direct-contact heat exchange for condensation for OC-OTEC applications. This is expected to provide a basis for optimizing OC-OTEC plant configurations. Using the model, we examined two condenser geometries, a cocurrent and a countercurrent configuration. This report provides detailed validation results for important condenser parameters for cocurrent and countercurrent flows. Based on the comparisons and uncertainty overlap between the experimental data and predictions, the model is shown to predict critical condenser performance parameters with an uncertainty acceptable for general engineering design and performance evaluations. 33 refs., 69 figs., 38 tabs.

  11. An elastic-plastic contact model for line contact structures

    Science.gov (United States)

    Zhu, Haibin; Zhao, Yingtao; He, Zhifeng; Zhang, Ruinan; Ma, Shaopeng

    2018-06-01

    Although numerical simulation tools are now very powerful, the development of analytical models is very important for the prediction of the mechanical behaviour of line contact structures for deeply understanding contact problems and engineering applications. For the line contact structures widely used in the engineering field, few analytical models are available for predicting the mechanical behaviour when the structures deform plastically, as the classic Hertz's theory would be invalid. Thus, the present study proposed an elastic-plastic model for line contact structures based on the understanding of the yield mechanism. A mathematical expression describing the global relationship between load history and contact width evolution of line contact structures was obtained. The proposed model was verified through an actual line contact test and a corresponding numerical simulation. The results confirmed that this model can be used to accurately predict the elastic-plastic mechanical behaviour of a line contact structure.

  12. Performance and Fouling Study of Asymmetric PVDF Membrane Applied in the Concentration of Organic Fertilizer by Direct Contact Membrane Distillation (DCMD

    Directory of Open Access Journals (Sweden)

    Yanfei Liu

    2018-02-01

    Full Text Available This study proposes using membrane distillation (MD as an alternative to the conventional multi-stage flushing (MSF process to concentrate a semi-product of organic fertilizer. By applying a unique asymmetric polyvinylidene fluoride (PVDF membrane, which was specifically designed for MD applications using a nonsolvent thermally induced phase separation (NTIPS method, the direct contact membrane distillation (DCMD performance was investigated in terms of its sustainability in permeation flux, fouling resistance, and anti-wetting properties. It was found that the permeation flux increased with increasing flow rate, while the top-surface facing feed mode was the preferred orientation to achieve 25% higher flux than the bottom-surface facing feed mode. Compared to the commercial polytetrafluoroethylene (PTFE membrane, the asymmetric PVDF membrane exhibited excellent anti-fouling and sustainable flux, with less than 8% flux decline in a 15 h continuous operation, i.e., flux decreased slightly and was maintained as high as 74 kg·m−2·h−1 at 70 °C. Meanwhile, the lost flux was easily recovered by clean water rinsing. Overall 2.6 times concentration factor was achieved in 15 h MD operation, with 63.4% water being removed from the fertilizer sample. Further concentration could be achieved to reach the desired industrial standard of 5x concentration factor.

  13. The role of creep in the time-dependent resistance of Ohmic gold contacts in radio frequency microelectromechanical system devices

    Science.gov (United States)

    Rezvanian, O.; Brown, C.; Zikry, M. A.; Kingon, A. I.; Krim, J.; Irving, D. L.; Brenner, D. W.

    2008-07-01

    It is shown that measured and calculated time-dependent electrical resistances of closed gold Ohmic switches in radio frequency microelectromechanical system (rf-MEMS) devices are well described by a power law that can be derived from a single asperity creep model. The analysis reveals that the exponent and prefactor in the power law arise, respectively, from the coefficient relating creep rate to applied stress and the initial surface roughness. The analysis also shows that resistance plateaus are not, in fact, limiting resistances but rather result from the small coefficient in the power law. The model predicts that it will take a longer time for the contact resistance to attain a power law relation with each successive closing of the switch due to asperity blunting. Analysis of the first few seconds of the measured resistance for three successive openings and closings of one of the MEMS devices supports this prediction. This work thus provides guidance toward the rational design of Ohmic contacts with enhanced reliabilities by better defining variables that can be controlled through material selection, interface processing, and switch operation.

  14. Contextual effect of positive intergroup contact on outgroup prejudice

    Science.gov (United States)

    Christ, Oliver; Schmid, Katharina; Lolliot, Simon; Swart, Hermann; Stolle, Dietlind; Tausch, Nicole; Al Ramiah, Ananthi; Wagner, Ulrich; Vertovec, Steven; Hewstone, Miles

    2014-01-01

    We assessed evidence for a contextual effect of positive intergroup contact, whereby the effect of intergroup contact between social contexts (the between-level effect) on outgroup prejudice is greater than the effect of individual-level contact within contexts (the within-level effect). Across seven large-scale surveys (five cross-sectional and two longitudinal), using multilevel analyses, we found a reliable contextual effect. This effect was found in multiple countries, operationalizing context at multiple levels (regions, districts, and neighborhoods), and with and without controlling for a range of demographic and context variables. In four studies (three cross-sectional and one longitudinal) we showed that the association between context-level contact and prejudice was largely mediated by more tolerant norms. In social contexts where positive contact with outgroups was more commonplace, norms supported such positive interactions between members of different groups. Thus, positive contact reduces prejudice on a macrolevel, whereby people are influenced by the behavior of others in their social context, not merely on a microscale, via individuals’ direct experience of positive contact with outgroup members. These findings reinforce the view that contact has a significant role to play in prejudice reduction, and has great policy potential as a means to improve intergroup relations, because it can simultaneously impact large numbers of people. PMID:24591627

  15. Contextual effect of positive intergroup contact on outgroup prejudice.

    Science.gov (United States)

    Christ, Oliver; Schmid, Katharina; Lolliot, Simon; Swart, Hermann; Stolle, Dietlind; Tausch, Nicole; Al Ramiah, Ananthi; Wagner, Ulrich; Vertovec, Steven; Hewstone, Miles

    2014-03-18

    We assessed evidence for a contextual effect of positive intergroup contact, whereby the effect of intergroup contact between social contexts (the between-level effect) on outgroup prejudice is greater than the effect of individual-level contact within contexts (the within-level effect). Across seven large-scale surveys (five cross-sectional and two longitudinal), using multilevel analyses, we found a reliable contextual effect. This effect was found in multiple countries, operationalizing context at multiple levels (regions, districts, and neighborhoods), and with and without controlling for a range of demographic and context variables. In four studies (three cross-sectional and one longitudinal) we showed that the association between context-level contact and prejudice was largely mediated by more tolerant norms. In social contexts where positive contact with outgroups was more commonplace, norms supported such positive interactions between members of different groups. Thus, positive contact reduces prejudice on a macrolevel, whereby people are influenced by the behavior of others in their social context, not merely on a microscale, via individuals' direct experience of positive contact with outgroup members. These findings reinforce the view that contact has a significant role to play in prejudice reduction, and has great policy potential as a means to improve intergroup relations, because it can simultaneously impact large numbers of people.

  16. CONTACT ANGLE OF YUCCA MOUNTAIN WELDED TUFF WITH WATER AND BRINES

    International Nuclear Information System (INIS)

    H. Kalia

    2006-01-01

    A number of tests were performed to acquire contact angles between Yucca Mountain welded tuff from Topopah Springs Lower Lithophysal geologic unit and various brine solutions. The tests were performed on core disks received from Sample Management Facility (SMF), oven dried to a constant weight and the core disks vacuum saturated in: distilled water, J-13 water, calcium chloride brine and sodium chloride brine to constant weight. The contact angles were acquired from eight points on the surface of the core disks, four on rough surface, and four on polished surface. The contact angle was measured by placing a droplet of the test fluid, distilled water, J-13 water, calcium chloride brine and sodium chloride brine on the core disks. The objective of this test was to acquire contact angles as a potential input to estimating capillary forces in accumulated dust on the waste packages and drip shields slated for the proposed High-Level Radioactive Waste Repository at Yucca Mountain, Nevada. It was noted that once the droplet contacts the test surface, it continues to spread hence the contact angle continues to decrease with elapsed time. The maximum observed angle was at time 0 or when the drop contacted the rock surface. The measured contact angle, in all cases has significant scatter. In general, the time zero contact angles for core disks saturated in sodium chloride brine were smaller than those saturated in calcium chloride brine, distilled water, and J-13 water. The contact angles for samples saturated in distilled water, J-13 water and calcium chloride brine at time zero were similar. There was slight difference between the observed contact angles for smooth and rough surface of the test samples. The contact angles for smooth surfaces were smaller than for the rough surfaces

  17. The Josephson effect in atomic contacts

    International Nuclear Information System (INIS)

    Chauvin, M.

    2005-11-01

    The Josephson effect appears when a weak-link establishes phase coherence between two superconductors. A unifying theory of this effect emerged in the 90's within the framework of mesoscopic physics. Based on two cornerstone concepts, conduction channels and Andreev reflection, it predicts the current-phase relation for the most basic weak-link: a single conduction channel of arbitrary transmission. This thesis illustrates this mesoscopic point of view with experiments on superconducting atomic size contacts. In particular, we have focused on the supercurrent peak around zero voltage, put into evidence the ac Josephson currents in a contact under constant bias voltage (Shapiro resonances and photon assisted multiple Andreev reflections), and performed direct measurements of the current-phase relation. (author)

  18. Equilibrium contact angle or the most-stable contact angle?

    Science.gov (United States)

    Montes Ruiz-Cabello, F J; Rodríguez-Valverde, M A; Cabrerizo-Vílchez, M A

    2014-04-01

    It is well-established that the equilibrium contact angle in a thermodynamic framework is an "unattainable" contact angle. Instead, the most-stable contact angle obtained from mechanical stimuli of the system is indeed experimentally accessible. Monitoring the susceptibility of a sessile drop to a mechanical stimulus enables to identify the most stable drop configuration within the practical range of contact angle hysteresis. Two different stimuli may be used with sessile drops: mechanical vibration and tilting. The most stable drop against vibration should reveal the changeless contact angle but against the gravity force, it should reveal the highest resistance to slide down. After the corresponding mechanical stimulus, once the excited drop configuration is examined, the focus will be on the contact angle of the initial drop configuration. This methodology needs to map significantly the static drop configurations with different stable contact angles. The most-stable contact angle, together with the advancing and receding contact angles, completes the description of physically realizable configurations of a solid-liquid system. Since the most-stable contact angle is energetically significant, it may be used in the Wenzel, Cassie or Cassie-Baxter equations accordingly or for the surface energy evaluation. © 2013 Elsevier B.V. All rights reserved.

  19. Pizza makers' contact dermatitis.

    Science.gov (United States)

    Lembo, Serena; Lembo, Claudio; Patruno, Cataldo; Balato, Anna; Balato, Nicola; Ayala, Fabio

    2014-01-01

    Contact eczema to foods, spices, and food additives can occur in occupational and nonoccupational settings in those who grow, handle, prepare, or cook food. Pizza is one of the most eaten foods in every continent, and pizza making is a common work in many countries. We aimed to evaluate the occurrence and the causes of contact dermatitis in pizza makers in Naples. We performed an observational study in 45 pizza makers: all the enrolled subjects had to answer a questionnaire designed to detect personal history of respiratory or cutaneous allergy, atopy; work characteristics and timing were also investigated. Every subject attended the dermatology clinic for a complete skin examination, and when needed, patients were patch tested using the Italian baseline series of haptens integrated with an arbitrary pizza makers series. Our results reported that 13.3% of the enrolled pizza makers (6/45) presented hand eczema, and that 8.9% (4/45) were affected by occupational allergic contact dermatitis. Diallyl disulfide and ammonium persulfate were the responsible substances. Performing patch tests in pizza makers and food handlers affected by hand contact dermatitis is useful. We propose a specific series of haptens for this wide working category.

  20. Clinical measurement of the height of the interproximal contact area in maxillary anterior teeth.

    Science.gov (United States)

    Sghaireen, Mohd G; Al-Zarea, Bader K; Al-Shorman, Hisham M; Al-Omiri, Mahmoud K

    2013-11-01

    To clinically quantify the apicoincisal height of interproximal areas directly in patients' mouths. Thirty participants (11 females and 9 males, mean age=26±1.5 years) were recruited into this study. Measurement of interproximal contact areas was carried out directly in patients' mouths using digital caliper (TERENSA, USA) with measuring accuracy of 0.01 mm. The interproximal contact areas that were measured are: central incisor to central incisor, central incisor to lateral incisor, lateral incisor to canine, and canine to first premolar on both sides of the jaw. Statistical significance was based on probability values less than 0.05 (pcontact point was the one present between central incisors and it ranged from 2.9 to 6.5 mm. On the other hand, the contact point between canine and first premolar was the smallest on both sides of the arch and ranged from 0.6 to 2.5 mm. The dimensions of the contact points declined as we move from anterior area backwards. Statistical analysis using t-test showed that there were significant differences between the measurements of interproximal points of each tooth (Pcontact point decreased as we moved from anterior to posterior teeth. The contact area between the central incisors was largest and the one between canine and premolar was the smallest. This study is the first to report direct intra-oral clinical measurement of contact points. Clinical evaluation of contact point dimensions using digital caliber is a viable, quick and accurate method to use.

  1. Familiarity breeds contempt: combining proximity loggers and GPS reveals female white-tailed deer (Odocoileus virginianus) avoiding close contact with neighbors.

    Science.gov (United States)

    Tosa, Marie I; Schauber, Eric M; Nielsen, Clayton K

    2015-01-01

    Social interactions can influence infectious disease dynamics, particularly for directly transmitted pathogens. Therefore, reliable information on contact frequency within and among groups can better inform disease modeling and management. We compared three methods of assessing contact patterns: (1) space-use overlap (volume of interaction [VI]), (2) direct contact rates measured by simultaneous global positioning system (GPS) locations (<10 m apart), and (3) direct contact rates measured by proximity loggers (PLs; 1-m detection) among female white-tailed deer (Odocoileus virginianus). We calculated the PL∶GPS contact ratios to see whether both devices reveal similar contact patterns and thus predict similar pathogen transmission patterns. Contact rates measured by GPS and PLs were similarly high for two within-group dyads (pairs of deer in the same social groups). Dyads representing separate but neighboring groups (high VI) had PL∶GPS contact ratios near zero, whereas dyads further apart (intermediate VI) had higher PL∶GPS contact ratios. Social networks based on PL contacts showed the fewest connected individuals and lowest mean centrality measures; network metrics were intermediate when based on GPS contacts and greatest when based on VI. Thus, the VI network portrayed animals to be more uniformly and strongly connected than did the PL network. We conclude that simultaneous GPS locations, compared with PLs, substantially underestimate the impact of group membership on direct contact rates of female deer and make networks appear more connected. We also present evidence that deer coming within the general vicinity of each other are less likely to come in close contact if they are in neighboring social groups than deer whose home ranges overlap little if at all. Combined, these results provide evidence that direct transmission of disease agents among female and juvenile white-tailed deer is likely to be constrained both spatially and by social structure, more

  2. A novel multi-stage direct contact membrane distillation module: Design, experimental and theoretical approaches.

    Science.gov (United States)

    Lee, Jung-Gil; Kim, Woo-Seung; Choi, June-Seok; Ghaffour, Noreddine; Kim, Young-Deuk

    2016-12-15

    An economic desalination system with a small scale and footprint for remote areas, which have a limited and inadequate water supply, insufficient water treatment and low infrastructure, is strongly demanded in the desalination markets. Here, a direct contact membrane distillation (DCMD) process has the simplest configuration and potentially the highest permeate flux among all of the possible MD processes. This process can also be easily instituted in a multi-stage manner for enhanced compactness, productivity, versatility and cost-effectiveness. In this study, an innovative, multi-stage, DCMD module under countercurrent-flow configuration is first designed and then investigate both theoretically and experimentally to identify its feasibility and operability for desalination application. Model predictions and measured data for mean permeate flux are compared and shown to be in good agreement. The effect of the number of module stages on the mean permeate flux, performance ratio and daily water production of the MDCMD system has been theoretically identified at inlet feed and permeate flow rates of 1.5 l/min and inlet feed and permeate temperatures of 70 °C and 25 °C, respectively. The daily water production of a three-stage DCMD module with a membrane area of 0.01 m 2  at each stage is found to be 21.5 kg. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Water in contact with extended hydrophobic surfaces: Direct evidence of weak dewetting

    International Nuclear Information System (INIS)

    Jensen, Torben R.; Kjaer, Kristian; Oestergaard Jensen, Morten; Peters, Guenther H.; Reitzel, Niels; Balashev, Konstantin; Bjoernholm, Thomas

    2003-01-01

    X-ray reflectivity measurements reveal a significant dewetting of a large hydrophobic paraffin surface floating on water. The dewetting phenomenon extends less than 15 A into the bulk water phase and results in an integrated density deficit of about one water molecule per 25-30 A 2 of water in contact with the paraffin surface. The results are supported by molecular dynamics simulations and related to the hydrophobic effect

  4. European social citizenship and gender: the part-time work directive

    NARCIS (Netherlands)

    Bleijenbergh, I.L.; de Bruijn, J.G.M.; Bussemaker, M.

    2004-01-01

    This article considers whether the development of European rights for workers implies a European social citizenship. It analyses the debate during the preparation and adoption of the EU Directive on part-time work in 1997, which guarantees part-time workers (who are primarily women) the same pay and

  5. High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients.

    Science.gov (United States)

    Sengor, Tomris; Kurna, Sevda Aydin; Aki, Suat; Ozkurt, Yelda

    2011-01-01

    The aim of the study was to examine the clinical success of high Dk (oxygen permeability) piggyback contact lens (PBCL) systems for the correction of contact lens intolerant keratoconus patients. Sixteen patients (29 eyes) who were not able to wear gas-permeable rigid lenses were included in this study. Hyper Dk silicone hydrogel (oxygen transmissibility or Dk/t = 150 units) and fluorosilicone methacrylate copolymer (Dk/t = 100 units) lenses were chosen as the PBCL systems. The clinical examinations included visual acuity and corneal observation by biomicroscopy, keratometer reading, and fluorescein staining before and after fitting the PBCL system. INDICATIONS FOR USING PBCL SYSTEM WERE: lens stabilization and comfort, improving comfort, and adding protection to the cone. Visual acuities increased significantly in all of the patients compared with spectacles (P = 0). Improvement in visual acuity compared with rigid lenses alone was recorded in 89.7% of eyes and no alteration of the visual acuity was observed in 10.3% of the eyes. Wearing time of PBCL systems for most of the patients was limited time (mean 6 months, range 3-12 months); thereafter they tolerated rigid lenses alone except for 2 patients. The PBCL system is a safe and effective method to provide centering and corneal protection against mechanical trauma by the rigid lenses for keratoconus patients and may increase contact lens tolerance.

  6. Contact lens wear and dry eyes: challenges and solutions

    Directory of Open Access Journals (Sweden)

    Markoulli M

    2017-02-01

    Full Text Available Maria Markoulli, Sailesh Kolanu School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia Abstract: The number of contact lens wearers worldwide has remained relatively stable over the past decade, despite the investment that has gone into contact lens technology. This is largely because 10%–50% of wearers dropout of contact lens wear within 3 years of commencement; the most common reason cited being contact lens discomfort (CLD. Of the symptoms reported, sensation of dry eye is the most common. Given the outcome of reduced wearing time, increased chair time, and ultimate contact lens discontinuation, the challenge is to identify the warning signs of CLD early on. Clinically detectable changes such as conjunctival staining, conjunctival indentation, conjunctival epithelial flap formation, lid wiper epitheliopathy, Demodex blepharitis, and meibomian gland dysfunction have been linked to CLD, highlighting the need to perform regular aftercare visits to identify these changes. At a cellular level, conjunctival metaplasia and reduced goblet cell density have been linked to CLD, leading to a downstream effect on the tear film breakup time of contact lens wearers. These factors suggest a strong link between CLD and friction, raising the need to target this as a means of minimizing CLD. The purpose of this review is to identify the clinical signs that relate to CLD as a means of earlier detection and management in order to combat contact lens dropout. Keywords: contact lens discomfort, dry eye disease, lid wiper epitheliopathy, tear film biomarkers, meibomian gland dysfunction

  7. Directed batch assembly of three-dimensional helical nanobelts through angular winding and electroplating

    International Nuclear Information System (INIS)

    Bell, D J; Bauert, T E; Zhang, L; Dong, L X; Sun, Y; Gruetzmacher, D; Nelson, B J

    2007-01-01

    This paper presents a new technique for the directed batch assembly of rolled-up three-dimensional helical nanobelts. The wet etch time is controlled in order for the loose end of the self-formed SiGe/Si/Cr nanobelts to be located over an electrode by taking advantage of the additional angular winding motion in the lateral direction. In a subsequent Au electroplating step, contacts are electroformed and the batch assembly is completed, while at the same time the conductance of the structures is increased

  8. Magnetosheath Propagation Time of Solar Wind Directional Discontinuities

    Science.gov (United States)

    Samsonov, A. A.; Sibeck, D. G.; Dmitrieva, N. P.; Semenov, V. S.; Slivka, K. Yu.; Å afránkova, J.; Němeček, Z.

    2018-05-01

    Observed delays in the ground response to solar wind directional discontinuities have been explained as the result of larger than expected magnetosheath propagation times. Recently, Samsonov et al. (2017, https://doi.org/10.1002/2017GL075020) showed that the typical time for a southward interplanetary magnetic field (IMF) turning to propagate across the magnetosheath is 14 min. Here by using a combination of magnetohydrodynamic simulations, spacecraft observations, and analytic calculations, we study the dependence of the propagation time on solar wind parameters and near-magnetopause cutoff speed. Increases in the solar wind speed result in greater magnetosheath plasma flow velocities, decreases in the magnetosheath thickness and, as a result, decreases in the propagation time. Increases in the IMF strength result in increases in the magnetosheath thickness and increases in the propagation time. Both magnetohydrodynamic simulations and observations suggest that propagation times are slightly smaller for northward IMF turnings. Magnetosheath flow deceleration must be taken into account when predicting the arrival times of solar wind structures at the dayside magnetopause.

  9. What does an intern doctor actually do? A quantification of time on work activities

    Directory of Open Access Journals (Sweden)

    James Jia Jun Chen

    2017-12-01

    Full Text Available Background Interns, or first year junior doctors, have traditionally been used as an adaptable frontline solution to many of the changes in healthcare, utilising their broad skill sets for both direct patient care and administrative burdens. While there are studies that focus on the total hours junior doctors work, there are few that analyse the specific tasks they do and how they dedicate their work time. Aims We aim to quantify the amount of time intern doctors spent on specific tasks during a shift. Methods This is a multi-centred, retrospective, self-reported study that was carried out in a public tertiary hospital network in Western Australia, comprising one tertiary, two metropolitan, and three regional hospitals. 68 individual shifts were reported, accounting for 605.72 hours. Participants reported time spent, in fifteen minute segments, on categories grossly defined as clerical tasks, clinical tasks, teaching, and personal time. Participants were also asked about their satisfaction with the amount of clinical exposure during the reported shift. Results Direct patient care accounted for 22 per cent of total shift time, indirect care 74 per cent, and personal time 4 per cent. Discharge summaries accounted for the most time-per-shift at 26 per cent, followed by medical note documentation at 14 per cent, with the least being teaching at 2 per cent. Direct patient contact by interns during a shift was on average 12 per cent (SD 14 per cent. 12 interns or 18 per cent of all responses reported no direct patient contact (0 per cent during a shift. Interns working in emergency medicine spent 44 per cent of their shift on direct patient contact, significantly more compared to their medicine and surgical colleagues. Conclusion Indirect care activities consume almost three times as much time as direct care activities. Interns are mostly unsatisfied with their amount of clinical exposure per shift. The results concur with the current literature of

  10. Infection dynamics in structured populations with disease awareness based on neighborhood contact history

    Science.gov (United States)

    Cao, Lang

    2014-10-01

    In recent years, continuing efforts have been directed to revealing the effect of human behavioral responses in the spread of infectious diseases. In this paper, we propose an implementation mechanism of disease awareness via individual self-perception from neighborhood contact histories (NCHs), where each individual is capable of memorizing a sequence of his infectious contacts earlier time, and adaptively adjusting the contact rate with his neighboring individuals as a preventive strategy from risks of exposure to infection. Both analytical and numerical results show that the NCH-based self-perceived awareness is a simple, but efficient disease control measure, which can greatly reduce the outbreak size of infectious diseases. We further examine the effects of a centralized disease control measure, which corresponds, for comparison, to an NCH-independent and uniformly aroused disease awareness. We find our proposed strategy outperforms the centralized one in a much larger and more practical range of epidemiological parameters, which also highlight the importance of the NCH-based awareness information in guidance of the individual protective behavior against infectious diseases.

  11. Role of aluminum in silver paste contact to boron-doped silicon emitters

    Directory of Open Access Journals (Sweden)

    Wei Wu

    2017-01-01

    Full Text Available The addition of aluminum to silver metallization pastes has been found to lower the contact resistivity of a silver metallization on boron-doped silicon emitters for n-type Si solar cells. However, the addition of Al also induces more surface recombination and increases the Ag pattern′s line resistivity, both of which ultimately limit the cell efficiency. There is a need to develop a fundamental understanding of the role that Al plays in reducing the contact resistivity and to explore alternative additives. A fritless silver paste is used to allow direct analysis of the impact of Al on the Ag-Si interfacial microstructure and isolate the influence of Al on the electrical contact from the complicated Ag-Si interfacial glass layer. Electrical analysis shows that in a simplified system, Al decreases the contact resistivity by about three orders of magnitude. Detailed microstructural studies show that in the presence of Al, microscale metallic spikes of Al-Ag alloy and nanoscale metallic spikes of Ag-Si alloy penetrate the surface of the boron-doped Si emitters. These results demonstrate the role of Al in reducing the contact resistivity through the formation of micro- and nano-scale metallic spikes, allowing the direct contact to the emitters.

  12. Eye contact perception in the West and East: a cross-cultural study.

    Directory of Open Access Journals (Sweden)

    Shota Uono

    Full Text Available This study investigated whether eye contact perception differs in people with different cultural backgrounds. Finnish (European and Japanese (East Asian participants were asked to determine whether Finnish and Japanese neutral faces with various gaze directions were looking at them. Further, participants rated the face stimuli for emotion and other affect-related dimensions. The results indicated that Finnish viewers had a smaller bias toward judging slightly averted gazes as directed at them when judging Finnish rather than Japanese faces, while the bias of Japanese viewers did not differ between faces from their own and other cultural backgrounds. This may be explained by Westerners experiencing more eye contact in their daily life leading to larger visual experience of gaze perception generally, and to more accurate perception of eye contact with people from their own cultural background particularly. The results also revealed cultural differences in the perception of emotion from neutral faces that could also contribute to the bias in eye contact perception.

  13. Eye contact perception in the West and East: a cross-cultural study.

    Science.gov (United States)

    Uono, Shota; Hietanen, Jari K

    2015-01-01

    This study investigated whether eye contact perception differs in people with different cultural backgrounds. Finnish (European) and Japanese (East Asian) participants were asked to determine whether Finnish and Japanese neutral faces with various gaze directions were looking at them. Further, participants rated the face stimuli for emotion and other affect-related dimensions. The results indicated that Finnish viewers had a smaller bias toward judging slightly averted gazes as directed at them when judging Finnish rather than Japanese faces, while the bias of Japanese viewers did not differ between faces from their own and other cultural backgrounds. This may be explained by Westerners experiencing more eye contact in their daily life leading to larger visual experience of gaze perception generally, and to more accurate perception of eye contact with people from their own cultural background particularly. The results also revealed cultural differences in the perception of emotion from neutral faces that could also contribute to the bias in eye contact perception.

  14. European Working Time Directive: implications for surgical training.

    LENUS (Irish Health Repository)

    Donohoe, C L

    2010-02-01

    The forthcoming implementation of the European Working Time Directive (EWTD) for non-consultant hospital doctors (NCHDs) poses a number of challenges in the areas of patient care, training, service provision and quality of life for workers. Surgery, as a craft-based speciality, will face a greater impact on training of future surgeons as operating time could be lost to service provision. The EWTD acts a stimulus for reform of current working practices and re-configuration of services. It will necessitate transformation of the way in which surgeons are trained, if current standards are to be maintained.

  15. Intraoral versus extraoral measurement of the height of the interproximal contact area in maxillary anterior teeth.

    Science.gov (United States)

    Sghaireen, Mohd G; Albhiran, Heyam Mobark; Alzoubi, Ibrahim A; Lynch, Edward; Al-Omiri, Mahmoud K

    2015-01-01

    This study aimed to clinically quantify the apicoincisal height of the upper interproximal areas directly in patients' mouths compared to measurements on stone models. One hundred and fifty participants (75 females and 75 males, age range 20-45 years) were recruited for this study. A digital caliper was used to measure the anterior maxillary interproximal contact areas directly in patients' mouths and on stone models. The digital caliper accuracy was up to 0.01. The Statistical Package for Social Sciences software (SPSS, version 19.0, Chicago, Ill., USA) was used for statistical analysis. Statistical significance was based on probability values contacts as well as the measurement on stone models showed that the dimensions of interproximal contacts on both sides of each tooth were significantly different (p contact point was larger than that of the distal contact point of each tooth. The largest contact point was the one between the central incisors (direct intraoral measurement = 2.9-6.49 mm; model measurement = 3.31-6.91 mm). On the other hand, the contact point between the canine and first premolar was the smallest on both sides of the arch (0.63-2.52 mm intraorally, 0.98-2.88 mm on models). The intraoral measurement of contact points was more accurate than model measurements, and the differences were statistically significant (p contact point dimensions using a digital caliper was more precise than measuring contact points on stone models; hence, it is a viable, quick and adequate method to be used routinely. © 2015 S. Karger AG, Basel.

  16. Contact, Perspective Taking, and Anxiety as Predictors of Stereotype Endorsement, Explicit Attitudes, and Implicit Attitudes

    OpenAIRE

    2007-01-01

    Abstract We proposed a model of intergroup contact wherein contact promotes understanding of outgroup perspectives, perspective taking relates to reduced intergroup anxiety that in turn is associated with lessened stereotyping and more positive intergroup attitudes. Additionally, we examined if implicit attitudes followed this model or were directly impacted by contact. White undergraduates (n = 153) completed measures of contact, perspective taking, intergroup anxiety, stereotype ...

  17. Longitudinal assessment of anti-PGL-I serology in contacts of leprosy patients in Bangladesh.

    Science.gov (United States)

    Richardus, Renate A; van der Zwet, Konrad; van Hooij, Anouk; Wilson, Louis; Oskam, Linda; Faber, Roel; van den Eeden, Susan J F; Pahan, David; Alam, Khorshed; Richardus, Jan Hendrik; Geluk, Annemieke

    2017-12-01

    Despite elimination efforts, the number of Mycobacterium leprae (M. leprae) infected individuals who develop leprosy, is still substantial. Solid evidence exists that individuals living in close proximity to patients are at increased risk to develop leprosy. Early diagnosis of leprosy in endemic areas requires field-friendly tests that identify individuals at risk of developing the disease before clinical manifestation. Such assays will simultaneously contribute to reduction of current diagnostic delay as well as transmission. Antibody (Ab) levels directed against the M.leprae-specific phenolic glycolipid I (PGL-I) represents a surrogate marker for bacterial load. However, it is insufficiently defined whether anti-PGL-I antibodies can be utilized as prognostic biomarkers for disease in contacts. Particularly, in Bangladesh, where paucibacillary (PB) patients form the majority of leprosy cases, anti-PGL-I serology is an inadequate method for leprosy screening in contacts as a directive for prophylactic treatment. Between 2002 and 2009, fingerstick blood from leprosy patients' contacts without clinical signs of disease from a field-trial in Bangladesh was collected on filter paper at three time points covering six years of follow-up per person. Analysis of anti-PGL-I Ab levels for 25 contacts who developed leprosy during follow-up and 199 contacts who were not diagnosed with leprosy, was performed by ELISA after elution of bloodspots from filter paper. Anti-PGL-I Ab levels at intake did not significantly differ between contacts who developed leprosy during the study and those who remained free of disease. Moreover, anti-PGL-I serology was not prognostic in this population as no significant correlation was identified between anti-PGL-I Ab levels at intake and the onset of leprosy. In this highly endemic population in Bangladesh, no association was observed between anti-PGL-I Ab levels and onset of disease, urging the need for an extended, more specific biomarker

  18. Directional short-time Fourier transform of distributions

    Directory of Open Access Journals (Sweden)

    Katerina Hadzi-Velkova Saneva

    2016-04-01

    Full Text Available Abstract In this paper we consider the directional short-time Fourier transform (DSTFT that was introduced and investigated in (Giv in J. Math. Anal. Appl. 399:100-107, 2013. We analyze the DSTFT and its transpose on test function spaces S ( R n $\\mathcal {S}(\\mathbb {R}^{n}$ and S ( Y 2 n $\\mathcal {S}(\\mathbb {Y}^{2n}$ , respectively, and prove the continuity theorems on these spaces. Then the obtained results are used to extend the DSTFT to spaces of distributions.

  19. Human sensitivity to eye contact in 2D and 3D videoconferencing

    NARCIS (Netherlands)

    Eijk, van R.L.J.; Kuijsters, A.; Dijkstra, K.I.; IJsselsteijn, W.A.

    2010-01-01

    Gaze awareness and eye contact serve important functions in social interaction. In order to maintain those functions in 2D and 3D videoconferencing systems, human sensitivity to eye contact and gaze direction needs to be taken into account in the design of such systems. Here we experimentally

  20. Reducing contact resistance in graphene devices through contact area patterning.

    Science.gov (United States)

    Smith, Joshua T; Franklin, Aaron D; Farmer, Damon B; Dimitrakopoulos, Christos D

    2013-04-23

    Performance of graphene electronics is limited by contact resistance associated with the metal-graphene (M-G) interface, where unique transport challenges arise as carriers are injected from a 3D metal into a 2D-graphene sheet. In this work, enhanced carrier injection is experimentally achieved in graphene devices by forming cuts in the graphene within the contact regions. These cuts are oriented normal to the channel and facilitate bonding between the contact metal and carbon atoms at the graphene cut edges, reproducibly maximizing "edge-contacted" injection. Despite the reduction in M-G contact area caused by these cuts, we find that a 32% reduction in contact resistance results in Cu-contacted, two-terminal devices, while a 22% reduction is achieved for top-gated graphene transistors with Pd contacts as compared to conventionally fabricated devices. The crucial role of contact annealing to facilitate this improvement is also elucidated. This simple approach provides a reliable and reproducible means of lowering contact resistance in graphene devices to bolster performance. Importantly, this enhancement requires no additional processing steps.

  1. The Degradation Interface of Magnesium Based Alloys in Direct Contact with Human Primary Osteoblast Cells.

    Science.gov (United States)

    Ahmad Agha, Nezha; Willumeit-Römer, Regine; Laipple, Daniel; Luthringer, Bérengère; Feyerabend, Frank

    2016-01-01

    Magnesium alloys have been identified as a new generation material of orthopaedic implants. In vitro setups mimicking physiological conditions are promising for material / degradation analysis prior to in vivo studies however the direct influence of cell on the degradation mechanism has never been investigated. For the first time, the direct, active, influence of human primary osteoblasts on magnesium-based materials (pure magnesium, Mg-2Ag and Mg-10Gd alloys) is studied for up to 14 days. Several parameters such as composition of the degradation interface (directly beneath the cells) are analysed with a scanning electron microscope equipped with energy dispersive X-ray and focused ion beam. Furthermore, influence of the materials on cell metabolism is examined via different parameters like active mineralisation process. The results are highlighting the influences of the selected alloying element on the initial cells metabolic activity.

  2. Development of a computational technique to measure cartilage contact area.

    Science.gov (United States)

    Willing, Ryan; Lapner, Michael; Lalone, Emily A; King, Graham J W; Johnson, James A

    2014-03-21

    Computational measurement of joint contact distributions offers the benefit of non-invasive measurements of joint contact without the use of interpositional sensors or casting materials. This paper describes a technique for indirectly measuring joint contact based on overlapping of articular cartilage computer models derived from CT images and positioned using in vitro motion capture data. The accuracy of this technique when using the physiological nonuniform cartilage thickness distribution, or simplified uniform cartilage thickness distributions, is quantified through comparison with direct measurements of contact area made using a casting technique. The efficacy of using indirect contact measurement techniques for measuring the changes in contact area resulting from hemiarthroplasty at the elbow is also quantified. Using the physiological nonuniform cartilage thickness distribution reliably measured contact area (ICC=0.727), but not better than the assumed bone specific uniform cartilage thicknesses (ICC=0.673). When a contact pattern agreement score (s(agree)) was used to assess the accuracy of cartilage contact measurements made using physiological nonuniform or simplified uniform cartilage thickness distributions in terms of size, shape and location, their accuracies were not significantly different (p>0.05). The results of this study demonstrate that cartilage contact can be measured indirectly based on the overlapping of cartilage contact models. However, the results also suggest that in some situations, inter-bone distance measurement and an assumed cartilage thickness may suffice for predicting joint contact patterns. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Dynamic solar-powered multi-stage direct contact membrane distillation system: Concept design, modeling and simulation

    KAUST Repository

    Lee, Jung Gil

    2017-04-26

    This paper presents a theoretical analysis of the monthly average daily and hourly performances of a solar-powered multi-stage direct contact membrane distillation (SMDCMD) system with an energy recovery scheme and dynamic operating system. Mid-latitude meteorological data from Busan, Korea is employed, featuring large climate variation over the course of one year. The number of module stages used by the dynamic operating scheme changes dynamically based on the inlet feed temperature of the successive modules, which results in an improvement of the water production and thermal efficiency. The simulations of the SMDCMD system are carried out to investigate the spatial and temporal variations in the feed and permeate temperatures and permeate flux. The monthly average daily water production increases from 0.37m3/day to 0.4m3/day and thermal efficiency increases from 31% to 45% when comparing systems both without and with dynamic operation in December. The water production with respect to collector area ranged from 350m2 to 550m2 and the seawater storage tank volume ranged from 16m3 to 28.8m3, and the solar fraction at various desired feed temperatures from 50°C to 80°C have been investigated in October and December.

  4. Corrosion of carbon steel in contact with bentonite

    International Nuclear Information System (INIS)

    Dobrev, D.; Vokal, A.; Bruha, P.

    2010-01-01

    Document available in extended abstract form only. Carbon steel canisters were chosen in a number of disposal concepts as reference material for disposal canisters. The corrosion rates of carbon steels in water solution both in aerobic and anaerobic conditions are well known, but only scarce data are available for corrosion behaviour of carbon steels in contact with bentonite. A special apparatus, which enables to measure corrosion rate of carbon steels under conditions simulating conditions in a repository, namely in contact with bentonite under high pressure and elevated temperatures was therefore prepared to study: - Corrosion rate of carbon steels in direct contact with bentonite in comparison with corrosion rate of carbon steels in synthetic bentonite pore water. - Influence of corrosion products on bentonite. The apparatus is composed of corrosion chamber containing a carbon steel disc in direct contact with compacted bentonite. Synthetic granitic water is above compacted bentonite under high pressure (50 - 100 bar) to simulate hydrostatic pressure in a repository. The experiments can be carried out under various temperatures. Bentonites used for experiments were Na-type of bentonite Volclay KWK 80 - 20 and Ca-Mg Czech bentonite from deposit Rokle. Before adding water into corrosion system the corrosion chamber was purged by nitrogen gas. The saturation of bentonite and corrosion rate were monitored by measuring consumption of water, pressure increase caused by swelling pressure of bentonite and by generation of hydrogen. Corrosion rate was also determined after corrosion experiments from weight loss of samples. The results of experiments show that the corrosion behaviour of carbon steels in contact with bentonite is very different from corrosion of carbon steels in water simulating bentonite pore water solution. The corrosion rates of carbon steel in contact with bentonite reached after 30 days of corrosion the values approaching 40 mm/yr contrary to values

  5. American Contact Dermatitis Society Contact Allergy Management Program: An Epidemiologic Tool to Determine Relative Prevalence of Contact Allergens.

    Science.gov (United States)

    Scheman, Andrew; Severson, David

    2016-01-01

    Data on the prevalence of contact allergy in North America are currently reported by groups of academic contact allergy specialists at select academic centers. Sampling of data from numerous centers across North America, including practices performing more limited patch testing, would provide a broader perspective of contact allergen prevalence in North America. The American Contact Dermatitis Society Contact Allergy Management Program is an ideal tool for collection of epidemiologic data regarding contact allergy prevalence in North America. The aim of the study was to identify the relative prevalence of contact allergy to common contact allergens in North America. Mapping of Contact Allergy Management Program (CAMP) data was performed to allow analysis of how frequently searches were performed for various contact allergens. The number of searches performed for specific allergens provides a measure of the relative prevalence of contact allergy to these allergens. The top 35 allergens for the period from November 18, 2012 to November 18, 2013 are reported. Although these data are useful, specific recommendations for minor alterations to CAMP are discussed, which will allow future CAMP data to be stratified and more powerful. With minor modifications, CAMP can provide a quantum leap in the reporting of contact allergy epidemiologic data in North America.

  6. A centrifugal direct recombinase polymerase amplification (direct-RPA) microdevice for multiplex and real-time identification of food poisoning bacteria.

    Science.gov (United States)

    Choi, Goro; Jung, Jae Hwan; Park, Byung Hyun; Oh, Seung Jun; Seo, Ji Hyun; Choi, Jong Seob; Kim, Do Hyun; Seo, Tae Seok

    2016-06-21

    In this study, we developed a centrifugal direct recombinase polymerase amplification (direct-RPA) microdevice for multiplex and real-time identification of food poisoning bacteria contaminated milk samples. The microdevice was designed to contain identical triplicate functional units and each unit has four reaction chambers, thereby making it possible to perform twelve direct-RPA reactions simultaneously. The integrated microdevice consisted of two layers: RPA reagents were injected in the top layer, while spiked milk samples with food poisoning bacteria were loaded into sample reservoirs in the bottom layer. For multiplex bacterial detection, the target gene-specific primers and probes were dried in each reaction chamber. The introduced samples and reagents could be equally aliquoted and dispensed into each reaction chamber by centrifugal force, and then the multiplex direct-RPA reaction was executed. The target genes of bacteria spiked in milk could be amplified at 39 °C without a DNA extraction step by using the direct-RPA cocktails, which were a combination of a direct PCR buffer and RPA enzymes. As the target gene amplification proceeded, the increased fluorescence signals coming from the reaction chambers were recorded in real-time at an interval of 2 min. The entire process, including the sample distribution, the direct-RPA reaction, and the real-time analysis, was accomplished with a custom-made portable genetic analyzer and a miniaturized optical detector. Monoplex, duplex, and triplex food poisoning bacteria (Salmonella enterica, Escherichia coli O157:H7, and Vibrio parahaemolyticus) detection was successfully performed with a detection sensitivity of 4 cells per 3.2 μL of milk samples within 30 min. By implementing the direct-PRA on the miniaturized centrifugal microsystem, the on-site food poisoning bacteria analysis would be feasible with high speed, sensitivity, and multiplicity.

  7. Static or breakloose friction for lubricated contacts: the role of surface roughness and dewetting

    International Nuclear Information System (INIS)

    Lorenz, B; Persson, B N J; Krick, B A; Sawyer, W G; Rodriguez, N; Mangiagalli, P

    2013-01-01

    We present experimental data for the static or breakloose friction for lubricated elastomer contacts, as a function of the time of stationary contact. Due to fluid squeeze-out from the asperity contact regions, the breakloose friction force increases continuously with the time of stationary contact. We consider three different cases: (a) PDMS rubber balls against flat smooth glass surfaces, (b) PDMS cylinder ribs against different substrates (glass, smooth and rough PMMA and an inert polymer) and (c) application to syringes. Due to differences in the surface roughness and contact pressures the three systems exhibit very different time dependences of the breakloose friction. In case (a) for rough surfaces the dry contact area A is a small fraction of the nominal contact area A 0 , and the fluid squeeze-out is fast. In case (b) the dry contact area is close to the nominal contact area, A/A 0 ≈ 1, and fluid squeeze-out is very slow due to percolation of the contact area. In this case, remarkably, different fluids with very different viscosities, ranging from 0.005 Pa s (water–glycerol mixture) to 1.48 Pa s (glycerol), give very similar breakloose friction forces as a function of the time of stationary contact. In case (c) the contact pressure and the surface roughness are larger than in case (b), and the squeeze-out is very slow so that even after a very long time the area of real contact is below the percolation threshold. For all cases (a)–(c), the increase in the breakloose friction is mainly due to the increase in the area of real contact with increasing time, because of the fluid squeeze-out and dewetting. (paper)

  8. Static or breakloose friction for lubricated contacts: the role of surface roughness and dewetting.

    Science.gov (United States)

    Lorenz, B; Krick, B A; Rodriguez, N; Sawyer, W G; Mangiagalli, P; Persson, B N J

    2013-11-06

    We present experimental data for the static or breakloose friction for lubricated elastomer contacts, as a function of the time of stationary contact. Due to fluid squeeze-out from the asperity contact regions, the breakloose friction force increases continuously with the time of stationary contact. We consider three different cases: (a) PDMS rubber balls against flat smooth glass surfaces, (b) PDMS cylinder ribs against different substrates (glass, smooth and rough PMMA and an inert polymer) and (c) application to syringes. Due to differences in the surface roughness and contact pressures the three systems exhibit very different time dependences of the breakloose friction. In case (a) for rough surfaces the dry contact area A is a small fraction of the nominal contact area A0, and the fluid squeeze-out is fast. In case (b) the dry contact area is close to the nominal contact area, A/A0 ≈ 1, and fluid squeeze-out is very slow due to percolation of the contact area. In this case, remarkably, different fluids with very different viscosities, ranging from 0.005 Pa s (water–glycerol mixture) to 1.48 Pa s (glycerol), give very similar breakloose friction forces as a function of the time of stationary contact. In case (c) the contact pressure and the surface roughness are larger than in case (b), and the squeeze-out is very slow so that even after a very long time the area of real contact is below the percolation threshold. For all cases (a)–(c), the increase in the breakloose friction is mainly due to the increase in the area of real contact with increasing time, because of the fluid squeeze-out and dewetting.

  9. Evaluation of residue-residue contact prediction in CASP10

    KAUST Repository

    Monastyrskyy, Bohdan

    2013-08-31

    We present the results of the assessment of the intramolecular residue-residue contact predictions from 26 prediction groups participating in the 10th round of the CASP experiment. The most recently developed direct coupling analysis methods did not take part in the experiment likely because they require a very deep sequence alignment not available for any of the 114 CASP10 targets. The performance of contact prediction methods was evaluated with the measures used in previous CASPs (i.e., prediction accuracy and the difference between the distribution of the predicted contacts and that of all pairs of residues in the target protein), as well as new measures, such as the Matthews correlation coefficient, the area under the precision-recall curve and the ranks of the first correctly and incorrectly predicted contact. We also evaluated the ability to detect interdomain contacts and tested whether the difficulty of predicting contacts depends upon the protein length and the depth of the family sequence alignment. The analyses were carried out on the target domains for which structural homologs did not exist or were difficult to identify. The evaluation was performed for all types of contacts (short, medium, and long-range), with emphasis placed on long-range contacts, i.e. those involving residues separated by at least 24 residues along the sequence. The assessment suggests that the best CASP10 contact prediction methods perform at approximately the same level, and comparably to those participating in CASP9.

  10. Determination of the response time of pressure transducers using the direct method

    International Nuclear Information System (INIS)

    Perillo, S.R.P.

    1994-01-01

    The available methods to determine the response time of nuclear safety related pressure transducers are discussed, with emphasis to the direct method. In order to perform the experiments, a Hydraulic Ramp Generator was built. The equipment produces ramp pressure transients simultaneously to a reference transducer and to the transducer under test. The time lag between the output of the two transducers, when they reach a predetermined setpoint, is measured as the time delay of the transducer under test. Some results using the direct method to determine the time delay of pressure transducers (1 E Class Conventional) are presented. (author). 18 refs, 35 figs, 12 tabs

  11. Language Contact.

    Science.gov (United States)

    Nelde, Peter Hans

    1995-01-01

    Examines the phenomenon of language contact and recent trends in linguistic contact research, which focuses on language use, language users, and language spheres. Also discusses the role of linguistic and cultural conflicts in language contact situations. (13 references) (MDM)

  12. Contact engineering for nano-scale CMOS

    KAUST Repository

    Hussain, Muhammad Mustafa

    2012-09-10

    High performance computation with longer battery lifetime is an essential component in our today\\'s digital electronics oriented life. To achieve these goals, field effect transistors based complementary metal oxide semiconductor play the key role. One of the critical requirements of transistor structure and fabrication is efficient contact engineering. To catch up with high performance information processing, transistors are going through continuous scaling process. However, it also imposes new challenges to integrate good contact materials in a small area. This can be counterproductive as smaller area results in higher contact resistance thus reduced performance for the transistor itself. At the same time, discovery of new one or two-dimensional materials like nanowire, nanotube, or atomic crystal structure materials, introduces new set of challenges and opportunities. In this paper, we are reviewing them in a synchronized fashion: fundamentals of contact engineering, evolution into non-planar field effect transistors, opportunities and challenges with one and two-dimensional materials and a new opportunity of contact engineering from device architecture perspective. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Financial Time Series Forecasting Using Directed-Weighted Chunking SVMs

    Directory of Open Access Journals (Sweden)

    Yongming Cai

    2014-01-01

    Full Text Available Support vector machines (SVMs are a promising alternative to traditional regression estimation approaches. But, when dealing with massive-scale data set, there exist many problems, such as the long training time and excessive demand of memory space. So, the SVMs algorithm is not suitable to deal with financial time series data. In order to solve these problems, directed-weighted chunking SVMs algorithm is proposed. In this algorithm, the whole training data set is split into several chunks, and then the support vectors are obtained on each subset. Furthermore, the weighted support vector regressions are calculated to obtain the forecast model on the new working data set. Our directed-weighted chunking algorithm provides a new method of support vectors decomposing and combining according to the importance of chunks, which can improve the operation speed without reducing prediction accuracy. Finally, IBM stock daily close prices data are used to verify the validity of the proposed algorithm.

  14. Degradation pattern of black phosphorus multilayer field-effect transistors in ambient conditions: Strategy for contact resistance engineering in BP transistors

    Science.gov (United States)

    Lee, Byung Chul; Kim, Chul Min; Jang, Ho-Kyun; Lee, Jae Woo; Joo, Min-Kyu; Kim, Gyu-Tae

    2017-10-01

    Black phosphorus (BP) has been proposed as a future optoelectronic material owing to its direct bandgap with excellent electrical performances. However, oxygen (O2) and water (H2O) molecules in an ambient condition can create undesired bubbles on the surface of the BP, resulting in hampering its excellent intrinsic properties. Here, we report the electrical degradation pattern of a mechanically exfoliated BP field-effect transistor (FET) in terms of the channel and contact, separately. Various electrical parameters such as the threshold voltage (VTH), carrier mobility (μ), contact resistance (RCT) and channel resistance (RCH) are estimated by the Y function method (YFM) with respect to time (up to 2000 min). It is found that RCT reduces and then, increases with time; whereas, the behavior of RCH is vice versa in ambient conditions. We attribute these effects to oxygen doping at the contact and the surface oxidation effects on the surface of the BP, respectively.

  15. The Degradation Interface of Magnesium Based Alloys in Direct Contact with Human Primary Osteoblast Cells.

    Directory of Open Access Journals (Sweden)

    Nezha Ahmad Agha

    Full Text Available Magnesium alloys have been identified as a new generation material of orthopaedic implants. In vitro setups mimicking physiological conditions are promising for material / degradation analysis prior to in vivo studies however the direct influence of cell on the degradation mechanism has never been investigated. For the first time, the direct, active, influence of human primary osteoblasts on magnesium-based materials (pure magnesium, Mg-2Ag and Mg-10Gd alloys is studied for up to 14 days. Several parameters such as composition of the degradation interface (directly beneath the cells are analysed with a scanning electron microscope equipped with energy dispersive X-ray and focused ion beam. Furthermore, influence of the materials on cell metabolism is examined via different parameters like active mineralisation process. The results are highlighting the influences of the selected alloying element on the initial cells metabolic activity.

  16. PREFACE: Non-contact AFM Non-contact AFM

    Science.gov (United States)

    Giessibl, Franz J.; Morita, Seizo

    2012-02-01

    This special issue is focussed on high resolution non-contact atomic force microscopy (AFM). Non-contact atomic force microscopy was established approximately 15 years ago as a tool to image conducting and insulating surfaces with atomic resolution. Since 1998, an annual international conference has taken place, and although the proceedings of these conferences are a useful source of information, several key developments warrant devoting a special issue to this subject. In the theoretic field, the possibility of supplementing established techniques such as scanning tunneling microscopy (STM) and Kelvin probe microscopy with atomically resolved force micrsoscopy poses many challenges in the calculation of contrast and contrast reversal. The surface science of insulators, self-assembled monolayers and adsorbates on insulators is a fruitful field for the application of non-contact AFM: several articles in this issue are devoted to these subjects. Atomic imaging and manipulation have been pioneered using STM, but because AFM allows the measurement of forces, AFM has had a profound impact in this field as well. Three-dimensional force spectroscopy has allowed many important insights into surface science. In this issue a combined 3D tunneling and force microscopy is introduced. Non-contact AFM typically uses frequency modulation to measure force gradients and was initially used mainly in a vacuum. As can be seen in this issue, frequency modulation is now also used in ambient conditions, allowing better spatial and force resolution. We thank all of the contributors for their time and efforts in making this special issue possible. We are also very grateful to the staff of IOP Publishing for handling the administrative aspects and for steering the refereeing process. Non-contact AFM contents Relation between the chemical force and the tunnelling current in atomic point contacts: a simple model Pavel Jelínek, Martin Ondrácek and Fernando Flores Theoretical simulation of

  17. Performance modeling of direct contact membrane distillation (DCMD) seawater desalination process using a commercial composite membrane

    KAUST Repository

    Lee, Junggil

    2015-01-10

    This paper presents the development of a rigorous theoretical model to predict the transmembrane flux of a flat sheet hydrophobic composite membrane, comprising both an active layer of polytetrafluoroethylene and a scrim-backing support layer of polypropylene, in the direct contact membrane distillation (DCMD) process. An integrated model includes the mass, momentum, species and energy balances for both retentate and permeate flows, coupled with the mass transfer of water vapor through the composite membrane and the heat transfer across the membrane and through the boundary layers adjacent to the membrane surfaces. Experimental results and model predictions for permeate flux and performance ratio are compared and shown to be in good agreement. The permeate flux through the composite layer can be ignored in the consideration of mass transfer pathways at the composite membrane. The effect of the surface porosity and the thickness of active and support layers on the process performance of composite membrane has also been studied. Among these parameters, surface porosity is identified to be the main factor significantly influencing the permeate flux and performance ratio, while the relative influence of the surface porosity on the performance ratio is less than that on flux.

  18. Genuine eye contact elicits self-referential processing.

    Science.gov (United States)

    Hietanen, Jonne O; Hietanen, Jari K

    2017-05-01

    The effect of eye contact on self-awareness was investigated with implicit measures based on the use of first-person singular pronouns in sentences. The measures were proposed to tap into self-referential processing, that is, information processing associated with self-awareness. In addition, participants filled in a questionnaire measuring explicit self-awareness. In Experiment 1, the stimulus was a video clip showing another person and, in Experiment 2, the stimulus was a live person. In both experiments, participants were divided into two groups and presented with the stimulus person either making eye contact or gazing downward, depending on the group assignment. During the task, the gaze stimulus was presented before each trial of the pronoun-selection task. Eye contact was found to increase the use of first-person pronouns, but only when participants were facing a real person, not when they were looking at a video of a person. No difference in self-reported self-awareness was found between the two gaze direction groups in either experiment. The results indicate that eye contact elicits self-referential processing, but the effect may be stronger, or possibly limited to, live interaction. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Distributed Tactical Decision Support by Using Real-Time Database System

    Science.gov (United States)

    1987-11-01

    appendix A and detailed in depth in the Advanced Combat Direction System Specification (reference 5). The assumption is that ’ ime 0 (TO) of any contact...CONSTELLATION LAUNCH I F14A CAPM 330 350 10000 STOP At simulated engagement minute 30. the following orders are next submitted to the event generator...time of contact (ETC). There is the assumption in the ETC calculation that COURSE will change such that the new report would be on a dead- reckoning

  20. A Framework for Better Understanding and Enhancing Direct Contact Membrane Distillation (DCMD) in Terms of Module Design, Cost Analysis and Energy Required

    KAUST Repository

    AbuHannoud, Ali

    2011-07-01

    Water is becoming scarcer and several authors have highlighted the upcoming problem of higher water salinity and the difficulty of treating and discharging water. Moreover, current discoveries of problems with chemicals that have been used for pretreating or post-treating water alerted scientists to research better solutions to treat water. Membrane distillation (MD) is a promising technology that might replace current processes as it has lower pretreatment requirements combined with a tremendous ability to treat a wide range of feed sources while producing very high product quality. If it enters the market, it will have a big influence on all products, from food industry to spaceflight. However, there are several problems which make MD a hot topic for research. One of them is the question about the real cost of MD in terms of heating feed and cooling distillate over time with respect to product quantity and quality. In this work, extensive heating and cooling analyses are covered to answer this question in order to enhance the MD process. Results show energy cost to produce water and the main source of energy loss for direct contact membrane distillation (DCMD), and several suggestions are made in order to better understand and hence enhance the process.

  1. Analysis of the thermal response of a BWR Mark-I containment shell to direct contact by molten core materials

    International Nuclear Information System (INIS)

    Kress, T.S.; Cleveland, J.C.

    1988-01-01

    This study was undertaken to evaluate the thermal response of a BWR Mark-I containment shell in the event of an accident severe enough for molten core materials to fall into the cavity beneath the rector vessel and eventually come into direct contact with the shell. An existing ORNL three-dimensional transient heat transport computer code, HEATING-6, was used for a specific 2-D case (and variations) for which representative melt/shell boundary conditions required as input were available from other studies. In addition to the use of HEATING-6, a simplified analytical steady-state correlation was developed and given the name BWR Liner Analysis Program (BWRLAP). BWRLAP was ''benchmarked'' by comparison with HEATING-6 and was then used to make a number of parametric calculations to investigate the sensitivities of the results to the inputs. 5 refs., 11 figs., 2 tabs

  2. A novel algorithm for determining contact area between a respirator and a headform.

    Science.gov (United States)

    Lei, Zhipeng; Yang, James; Zhuang, Ziqing

    2014-01-01

    The contact area, as well as the contact pressure, is created when a respiratory protection device (a respirator or surgical mask) contacts a human face. A computer-based algorithm for determining the contact area between a headform and N95 filtering facepiece respirator (FFR) was proposed. Six N95 FFRs were applied to five sizes of standard headforms (large, medium, small, long/narrow, and short/wide) to simulate respirator donning. After the contact simulation between a headform and an N95 FFR was conducted, a contact area was determined by extracting the intersection surfaces of the headform and the N95 FFR. Using computer-aided design tools, a superimposed contact area and an average contact area, which are non-uniform rational basis spline (NURBS) surfaces, were developed for each headform. Experiments that directly measured dimensions of the contact areas between headform prototypes and N95 FFRs were used to validate the simulation results. Headform sizes influenced all contact area dimensions (P contact area dimensions (P contact area, while the large and small headforms produced the smallest.

  3. A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.

    Science.gov (United States)

    Fong, Ee-May; Chung, Wan-Young

    2015-08-05

    A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.

  4. Borehole radar directionality in the time domain in small aperture antennas

    CSIR Research Space (South Africa)

    Vogt, DR

    2008-06-01

    Full Text Available by interpolation. Initial tests show that mutual coupling between the antenna elements does affect the relative timing, but does not prevent the extraction of usable directional data. Experimental data from a test tank confirms that estimates of reflector... the phase differ- ences at each antenna. They showed that mutual cou- pling was tolerable. In a related paper [9] they presented an algorithm to recover direction that performed well. II. SYSTEM DESCRIPTION In this paper, a directional antenna...

  5. Identification of risk products for fragrance contact allergy

    DEFF Research Database (Denmark)

    Johansen, Jeanne Duus; Andersen, T F; Kjøller, M

    1998-01-01

    BACKGROUND: Fragrances are the first or second most common cause of contact allergy in dermatitis patients. OBJECTIVE: The aim of this study was to identify risk products for fragrance contact allergy. METHODS: The design was a case-control study with a case group of 78 fragrance-mix-positive ecz......BACKGROUND: Fragrances are the first or second most common cause of contact allergy in dermatitis patients. OBJECTIVE: The aim of this study was to identify risk products for fragrance contact allergy. METHODS: The design was a case-control study with a case group of 78 fragrance......-mix-positive eczema patients and two control groups, one consisting of 1,279 subjects selected as a random sample of the general population and the other consisting of 806 fragrance-mix-negative eczema patients. The identification of risk products was based on the patients' histories of rash to scented products....... Analysis of the associations between first-time rash caused by different specified product categories and fragrance mix sensitivity was performed using logistic regression. RESULTS: It was found that first-time rash caused by deodorant sprays and/or perfumes were related to fragrance contact allergy...

  6. Concerns about Appearing Prejudiced Get Under the Skin: Stress Responses to Interracial Contact in the Moment and across Time

    OpenAIRE

    Trawalter, Sophie; Adam, Emma K.; Chase-Lansdale, P. Lindsay; Richeson, Jennifer A.

    2012-01-01

    Many White Americans are concerned about appearing prejudiced. How these concerns affect responses during actual interracial interactions, however, remains understudied. The present work examines stress responses to interracial contact—both in the moment, during interracial interactions (Study 1), and over time as individuals have repeated interracial contact (Study 2). Results of Study 1 revealed that concerns about appearing prejudiced were associated with heightened stress responses during...

  7. Evaluation of anti-tuberculosis antibodies in healthy contact and non-contacts persons

    International Nuclear Information System (INIS)

    Aziz, N; Bukhari, M.H; Muneer, M; Tayyab, M; Chaudhry, N.A.

    2006-01-01

    This study was conducted to see the presence of the antimycobacterial antibodies in healthy household contacts of tuberculosis patients and healthy normal subjects who have never been in contact with tuberculosis patients. A total of 200 subjects, 120 with history of household contact and 80 without such history were included in the study. Routine Haematological investigations were performed and all the sera of 200 subjects were tested who 19M, 19G and IgA anti tuberculosis antibodies using ELISA technique. There was no difference in the average age of the household contacts and non-contacts. The complaints of pyrexia, night sweats and loss of weight was more in house hold contacts as compared to non-contacts. The awareness about BCG vaccination was equal among the household contacts and non-contacts. The combined serological positivity of the household contacts was 65.8% and the combined serological positivity for non-contacts was 34.1%. There was no statistically significant difference in the presence of 19M among household contacts as compared to non-contacts. However both IgG and 19A were present in significantly higher number of household contacts as compared to non contacts. This study concludes that the persons living in the house with a patient suffering from active pulmonary tuberculosis (household contact) have more chances of being infected with Mycobacterium tuberculosis as compared to the healthy non-contacts. (author)

  8. Effect of feed flow pattern on the distribution of permeate fluxes in desalination by direct contact membrane distillation

    KAUST Repository

    Soukane, Sofiane

    2017-05-31

    The current study aims to highlight the effect of flow pattern on the variations of permeate fluxes over the membrane surface during desalination in a direct contact membrane distillation (DCMD) flat module. To do so, a three dimensional (3D) Computational Fluid Dynamics (CFD) model with embedded pore scale calculations is implemented to predict flow, heat and mass transfer in the DCMD module. Model validation is carried out in terms of average permeate fluxes with experimental data of seawater desalination using two commercially available PTFE membranes. Average permeate fluxes agree within 6% and less with experimental values without fitting parameters. Simulation results show that the distribution of permeate fluxes and seawater salinity over the membrane surface are strongly dependent on momentum and heat transport and that temperature and concentration polarization follow closely the flow distribution. The analysis reveals a drastic effect of recirculation loops and dead zones on module performance and recommendations to improve MD flat module design are drawn consequently.

  9. New reassortant and enzootic European swine influenza 1 viruses transmits efficiently through direct contact in the ferret model

    DEFF Research Database (Denmark)

    Fobian, Kristina; P. Fabrizio, Thomas; Yoon, Sun-Woo

    2015-01-01

    The reverse zoonotic events that introduced the 2009 pandemic influenza virus into pigs have drastically increased the diversity of swine influenza viruses in Europe. The pandemic potential of these novel reassortments is still unclear, necessitating enhanced surveillance of European pigs...... with additional focus on risk assessment of these new viruses. In this study, four European swine influenza viruses were assessed for their zoonotic potential. Two of the four viruses were enzootic viruses of subtype H1N2 (with avian-like H1) and H3N2 and two were new reassortants, one with avian-like H1...... and human-like N2 and one with 2009 pandemic H1 and swine-like N2. All viruses replicated to high titers in nasal wash- and nasal turbinate samples from inoculated ferrets and transmitted efficiently by direct contact. Only the H3N2 virus transmitted to naïve ferrets via the airborne route. Growth kinetics...

  10. Versatile directional searches for gravitational waves with Pulsar Timing Arrays

    Science.gov (United States)

    Madison, D. R.; Zhu, X.-J.; Hobbs, G.; Coles, W.; Shannon, R. M.; Wang, J. B.; Tiburzi, C.; Manchester, R. N.; Bailes, M.; Bhat, N. D. R.; Burke-Spolaor, S.; Dai, S.; Dempsey, J.; Keith, M.; Kerr, M.; Lasky, P.; Levin, Y.; Osłowski, S.; Ravi, V.; Reardon, D.; Rosado, P.; Spiewak, R.; van Straten, W.; Toomey, L.; Wen, L.; You, X.

    2016-02-01

    By regularly monitoring the most stable millisecond pulsars over many years, pulsar timing arrays (PTAs) are positioned to detect and study correlations in the timing behaviour of those pulsars. Gravitational waves (GWs) from supermassive black hole binaries (SMBHBs) are an exciting potentially detectable source of such correlations. We describe a straightforward technique by which a PTA can be `phased-up' to form time series of the two polarization modes of GWs coming from a particular direction of the sky. Our technique requires no assumptions regarding the time-domain behaviour of a GW signal. This method has already been used to place stringent bounds on GWs from individual SMBHBs in circular orbits. Here, we describe the methodology and demonstrate the versatility of the technique in searches for a wide variety of GW signals including bursts with unmodelled waveforms. Using the first six years of data from the Parkes Pulsar Timing Array, we conduct an all-sky search for a detectable excess of GW power from any direction. For the lines of sight to several nearby massive galaxy clusters, we carry out a more detailed search for GW bursts with memory, which are distinct signatures of SMBHB mergers. In all cases, we find that the data are consistent with noise.

  11. Contact Lens Care

    Science.gov (United States)

    ... Consumers Consumer Information by Audience For Women Contact Lens Care Share Tweet Linkedin Pin it More sharing ... www.fda.gov/medwatch Learn More about Contact Lens Care Other Tips on Contact Lenses Decorative Contact ...

  12. Contact lens disinfection by ultraviolet light

    International Nuclear Information System (INIS)

    Dolman, P.J.; Dobrogowski, M.J.

    1989-01-01

    A 253.7-nm ultraviolet light with an intensity of 1,100 microW/cm2 was tested for its germicidal activity against contact lenses and storage solutions contaminated with various corneal pathogens. The exposure time necessary to reduce a concentration of organisms from 10(6)/ml to less than 10/ml was 30 seconds for Staphylococcus aureus, 60 seconds for Pseudomonas aeruginosa, and 84 seconds for Candida albicans. The time necessary to sterilize a suspension of 10(4)/ml Acanthamoeba polyphaga was less than three minutes with this technique. Four brands of soft contact lenses were exposed to ultraviolet light for over eight hours without changing their appearance, comfort, or refraction

  13. Time-resolved studies of direct effects of radiation on DNA

    International Nuclear Information System (INIS)

    Fielden, E.M.; O'Neill, P.; Al-Kazwini, A.

    1987-01-01

    The biological changes induced by ionising radiation are a consequence of radiation-induced chemical events taking place at times <1s. These events are strongly influenced by the presence of chemical modifiers. Since DNA is a principle target for radiation-induced cell killing, DNA-free radicals are generated by direct ionisation of DNA moieties (direct effect) and by reaction with hydroxyl radicals formed by radiolysis of the water which is in the vicinity of the DNA (indirect effect). In order to study the 'direct' effects of radiation on DNA the following model approaches are discussed:- 1) Use of the technique of pulse radiolysis to investigate in aqueous solution the interactions of deoxynucleosides with SO/sub 4//sup .-/ whereby one-electron oxidised species of the bases are generated; and 2) time resolved, radiation-induced changes to solid DNA and related macromolecules (e.g. radiation-induced luminescence) in order to obtain an understanding of charge/energy migration as a result of ionisation of DNA. The influence of chemical modifiers and of environment is discussed in terms of the properties of the radiation-induced species produced. Since the properties of base radicals produced by SO/sub 4//sup .-/ are similar to those of the base OH-adducts oxidising properties, potential similarities between the 'direct' and 'indirect' effects of radiation are presented

  14. Real-time visualization of dynamic particle contact failures

    Energy Technology Data Exchange (ETDEWEB)

    Parab, Niranjan D.; Hudspeth, Matthew; Claus, Ben; Guo, Zherui; Sun, Tao; Fezzaa, Kamel; Chen, Weinong W.

    2017-01-01

    Granular materials are widely used to resist impact and blast. Under these dynamic loadings, the constituent particles in the granular system fracture. To study the fracture mechanisms in brittle particles under dynamic compressive loading, a high speed X-ray phase contrast imaging setup was synchronized with a Kolsky bar apparatus. Controlled compressive loading was applied on two contacting particles using the Kolsky bar apparatus and fracture process was captured using the high speed X-ray imaging setup. Five different particles were investigated: soda-lime glass, polycrystalline silica (silicon dioxide), polycrystalline silicon, barium titanate glass, and yttrium stabilized zirconia. For both soda lime glass and polycrystalline silica particles, one of the particles fragmented explosively, thus breaking into many small pieces. For Silicon and barium titanate glass particles, a finite number of cracks were observed in one of the particles causing it to fracture. For yttrium stabilized zirconia particles, a single meridonial crack developed in one of the particles, breaking it into two parts.

  15. High performance MoS2 TFT using graphene contact first process

    Directory of Open Access Journals (Sweden)

    Chih-Shiang Chang Chien

    2017-08-01

    Full Text Available An ohmic contact of graphene/MoS2 heterostructure is determined by using ultraviolet photoelectron spectroscopy (UPS. Since graphene shows a great potential to replace metal contact, a direct comparison of Cr/Au contact and graphene contact on the MoS2 thin film transistor (TFT is made. Different from metal contacts, the work function of graphene can be modulated. As a result, the subthreshold swing can be improved. And when Vgcontact can achieve lower off current by lowering the Fermi level. To further improve the performance of MoS2 TFT, a new method using graphene contact first and MoS2 layer last process that can avoid PMMA residue and high processing temperature is applied. MoS2 TFT using this method shows on/off current ratio up to 6×106 order of magnitude, high mobility of 116 cm2/V-sec, and subthreshold swing of only 0.515 V/dec.

  16. A Practitioner Model for Increasing Eye Contact in Children With Autism.

    Science.gov (United States)

    Cook, Jennifer L; Rapp, John T; Mann, Kathryn R; McHugh, Catherine; Burji, Carla; Nuta, Raluca

    2017-05-01

    Although many teaching techniques for children with autism spectrum disorder (ASD) require the instructor to gain the child's eye contact prior to delivering an instructional demand, the literature contains notably few procedures that reliably produce this outcome. To address this problem, we evaluated the effects of a sequential model for increasing eye contact in children with ASD. The model included the following phases: contingent praise only (for eye contact), contingent edibles plus praise, stimulus prompts plus contingent edibles and praise, contingent video and praise, schedule thinning, and maintenance evaluations for up to 2 years. Results indicated that the procedures increased eye contact for 20 participants (one additional participant did not require consequences). For 16 participants, praise (alone) was not sufficient to support eye contact; however, high levels of eye contact were typically maintained with these participants when therapists used combined schedules of intermittent edibles or video and continuous praise. We discuss some limitations of this model and directions for future research on increasing eye contact for children with ASD.

  17. An infrared-driven flexible pyroelectric generator for non-contact energy harvester

    Science.gov (United States)

    Zhao, Tingting; Jiang, Weitao; Liu, Hongzhong; Niu, Dong; Li, Xin; Liu, Weihua; Li, Xuan; Chen, Bangdao; Shi, Yongsheng; Yin, Lei; Lu, Bingheng

    2016-04-01

    In recent years, energy harvesting technologies, which can scavenge many kinds of energies from our living environment to power micro/nanodevices, have attracted increasing attention. However, remote energy transmission, flexibility and electric waveform controllability remain the key challenges for wireless power supply by an energy harvester. In this paper, we design a new infrared-driven non-contact pyroelectric generator for harvesting heat energy, which avoids direct contact between the pyroelectric generator and heat source and realizes remote energy transfer exploiting the photothermal and penetrability of infrared light. The output voltage (under the input impedance of 100 MOhm) and short-circuit current of the pyroelectric generator consisting of a CNT/PVDF/CNT layer (20 mm × 5 mm × 100 μm) can be as large as 1.2 V and 9 nA, respectively, under a 1.45 W cm-2 near-infrared laser (808 nm). We also demonstrate the means by which the pyroelectric generator can modulate square waveforms with controllable periods through irradiation frequency, which is essential for signal sources and medical stimulators. The overshoot of square waveforms are in a range of 9.0%-13.1% with a rise time of 120 ms. The prepared pyroelectric generator can light a liquid crystal display (LCD) in a vacuum chamber from outside. This work paves the way for non-contact energy harvesting for some particular occasions where near-field energy control is not available.In recent years, energy harvesting technologies, which can scavenge many kinds of energies from our living environment to power micro/nanodevices, have attracted increasing attention. However, remote energy transmission, flexibility and electric waveform controllability remain the key challenges for wireless power supply by an energy harvester. In this paper, we design a new infrared-driven non-contact pyroelectric generator for harvesting heat energy, which avoids direct contact between the pyroelectric generator and heat

  18. Hydrodynamic instability induced liquid--solid contacts in film boiling

    International Nuclear Information System (INIS)

    Yao, S.; Henry, R.E.

    1976-01-01

    The film boiling liquid-solid contacts of saturated ethanol and water to horizontal flat gold plated copper are examined by using electric conductance probe. It is observed that the liquid-solid contacts occur over a wide temperature range, and generally, induced by hydrodynamic instabilities. The area of contact decreases exponentially with interface temperature and is liquid depth dependent. The averaged duration of contacts is strongly influenced by the dominant nucleation process, and thus, depends on the interface temperature and the wettability of the solid during the contact. The frequency of major contacts is about 1.5 times the bubble detaching frequency. It is found that the liquid-solid contacts may account for a large percentage of the film boiling heat transfer near the low temperature end of film boiling and decreases as the interface temperature increases

  19. Modeling 3D conjugate heat and mass transfer for turbulent air drying of Chilean papaya in a direct contact dryer

    Science.gov (United States)

    Lemus-Mondaca, Roberto A.; Vega-Gálvez, Antonio; Zambra, Carlos E.; Moraga, Nelson O.

    2017-01-01

    A 3D model considering heat and mass transfer for food dehydration inside a direct contact dryer is studied. The k- ɛ model is used to describe turbulent air flow. The samples thermophysical properties as density, specific heat, and thermal conductivity are assumed to vary non-linearly with temperature. FVM, SIMPLE algorithm based on a FORTRAN code are used. Results unsteady velocity, temperature, moisture, kinetic energy and dissipation rate for the air flow are presented, whilst temperature and moisture values for the food also are presented. The validation procedure includes a comparison with experimental and numerical temperature and moisture content results obtained from experimental data, reaching a deviation 7-10 %. In addition, this turbulent k- ɛ model provided a better understanding of the transport phenomenon inside the dryer and sample.

  20. Aluminum–Titanium Alloy Back Contact Reducing Production Cost of Silicon Thin-Film Solar Cells

    Directory of Open Access Journals (Sweden)

    Hsin-Yu Wu

    2016-11-01

    Full Text Available In this study, metal films are fabricated by using an in-line reactive direct current magnetron sputtering system. The aluminum–titanium (AlTi back contacts are prepared by changing the pressure from 10 mTorr to 25 mTorr. The optical, electrical and structural properties of the metal back contacts are investigated. The solar cells with the AlTi had lower contact resistance than those with the silver (Ag back contact, resulting in a higher fill factor. The AlTi contact can achieve a solar cell conversion efficiency as high as that obtained from the Ag contact. These findings encourage the potential adoption of AlTi films as an alternative back contact to silver for silicon thin-film solar cells.

  1. Neural activity in the posterior superior temporal region during eye contact perception correlates with autistic traits.

    Science.gov (United States)

    Hasegawa, Naoya; Kitamura, Hideaki; Murakami, Hiroatsu; Kameyama, Shigeki; Sasagawa, Mutsuo; Egawa, Jun; Endo, Taro; Someya, Toshiyuki

    2013-08-09

    The present study investigated the relationship between neural activity associated with gaze processing and autistic traits in typically developed subjects using magnetoencephalography. Autistic traits in 24 typically developed college students with normal intelligence were assessed using the Autism Spectrum Quotient (AQ). The Minimum Current Estimates method was applied to estimate the cortical sources of magnetic responses to gaze stimuli. These stimuli consisted of apparent motion of the eyes, displaying direct or averted gaze motion. Results revealed gaze-related brain activations in the 150-250 ms time window in the right posterior superior temporal sulcus (pSTS), and in the 150-450 ms time window in medial prefrontal regions. In addition, the mean amplitude in the 150-250 ms time window in the right pSTS region was modulated by gaze direction, and its activity in response to direct gaze stimuli correlated with AQ score. pSTS activation in response to direct gaze is thought to be related to higher-order social processes. Thus, these results suggest that brain activity linking eye contact and social signals is associated with autistic traits in a typical population. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  2. Navigation Strategy by Contact Sensing Interaction for a Biped Humanoid Robot

    Directory of Open Access Journals (Sweden)

    Hanafiah Yussof

    2008-11-01

    Full Text Available This report presents a basic contact interaction-based navigation strategy for a biped humanoid robot to support current visual-based navigation. The robot's arms were equipped with force sensors to detect physical contact with objects. We proposed a motion algorithm consisting of searching tasks, self-localization tasks, correction of locomotion direction tasks and obstacle avoidance tasks. Priority was given to right-side direction to navigate the robot locomotion. Analysis of trajectory generation, biped gait pattern, and biped walking characteristics was performed to define an efficient navigation strategy in a biped walking humanoid robot. The proposed algorithm is evaluated in an experiment with a 21-dofs humanoid robot operating in a room with walls and obstacles. The experimental results reveal good robot performance when recognizing objects by touching, grasping, and continuously generating suitable trajectories to correct direction and avoid collisions.

  3. How to make sticky surfaces slippery: Contact angle hysteresis in electrowetting with alternating voltage

    NARCIS (Netherlands)

    Li, F.; Li, F.; Mugele, Friedrich Gunther

    2008-01-01

    Contact angle hysteresis caused by random pinning forces is a major obstacle in moving small quantities of liquid on solid surfaces. Here, we demonstrate that the contact angle hysteresis for sessile drops in electrowetting almost disappears with increasing alternating voltage, whereas for direct

  4. Apparent contact angle and contact angle hysteresis on liquid infused surfaces.

    Science.gov (United States)

    Semprebon, Ciro; McHale, Glen; Kusumaatmaja, Halim

    2016-12-21

    We theoretically investigate the apparent contact angle and contact angle hysteresis of a droplet placed on a liquid infused surface. We show that the apparent contact angle is not uniquely defined by material parameters, but also has a dependence on the relative size between the droplet and its surrounding wetting ridge formed by the infusing liquid. We derive a closed form expression for the contact angle in the limit of vanishing wetting ridge, and compute the correction for small but finite ridge, which corresponds to an effective line tension term. We also predict contact angle hysteresis on liquid infused surfaces generated by the pinning of the contact lines by the surface corrugations. Our analytical expressions for both the apparent contact angle and contact angle hysteresis can be interpreted as 'weighted sums' between the contact angles of the infusing liquid relative to the droplet and surrounding gas phases, where the weighting coefficients are given by ratios of the fluid surface tensions.

  5. Evaluation of metal–nanowire electrical contacts by measuring contact end resistance

    International Nuclear Information System (INIS)

    Park, Hongsik; Beresford, Roderic; Xu, Jimmy; Ha, Ryong; Choi, Heon-Jin; Shin, Hyunjung

    2012-01-01

    It is known, but often unappreciated, that the performance of nanowire (NW)-based electrical devices can be significantly affected by electrical contacts between electrodes and NWs, sometimes to the extent that it is really the contacts that determine the performance. To correctly understand and design NW device operation, it is thus important to carefully measure the contact resistance and evaluate the contact parameters, specific contact resistance and transfer length. A four-terminal pattern or a transmission line model (TLM) pattern has been widely used to measure contact resistance of NW devices and the TLM has been typically used to extract contact parameters of NW devices. However, the conventional method assumes that the electrical properties of semiconducting NW regions covered by a metal are not changed after electrode formation. In this study, we report that the conventional methods for contact evaluation can give rise to considerable errors because of an altered property of the NW under the electrodes. We demonstrate that more correct contact resistance can be measured from the TLM pattern rather than the four-terminal pattern and correct contact parameters including the effects of changed NW properties under electrodes can be evaluated by using the contact end resistance measurement method. (paper)

  6. Low resistivity contacts to YBa2Cu3O(7-x) superconductors

    Science.gov (United States)

    Hsi, Chi-Shiung; Haertling, Gene H.

    1991-01-01

    Silver, gold, platinum, and palladium metals were investigated as electroding materials for the YBa2Cu3O(7-x) superconductors. Painting, embedding, and melting techniques were used to apply the electrodes. Contact resistivities were determined by: (1) type of electrode; (2) firing conditions; and (3) application method. Electrodes fired for long times exhibited lower contact resistivities than those fired for short times. Low-resistivity contacts were found for silver and gold electrodes. Silver, which made good ohmic contact to the YBa2Cu3O(7-x) superconductor with low contact resistivities was found to be the best electroding material among the materials evaluated in this investigation.

  7. Direct Mail Marketing for Cooperative Education. Cooperative Education Marketing Digest Series 5.

    Science.gov (United States)

    McGookey, Kathy

    Seven guidelines for enhancing direct mail marketing are as follows: target the most promising audience; frame the right message for the audience; state the benefits of making a positive response; send the message at an appropriate time; tell the reader what response is desired; plan follow-up mailings or other contact; and measure results.…

  8. Gigantic Enhancement in Sensitivity Using Schottky Contacted Nanowire Nanosensor

    KAUST Repository

    Wei, Te-Yu; Yeh, Ping-Hung; Lu, Shih-Yuan; Wang, Zhong Lin

    2009-01-01

    A new single nanowire based nanosensor is demonstrated for illustrating its ultrahigh sensitivity for gas sensing. The device is composed of a single ZnO nanowire mounted on Pt electrodes with one end in Ohmic contact and the other end in Schottky contact. The Schottky contact functions as a "gate" that controls the current flowing through the entire system. By tuning the Schottky barrier height through the responsive variation of the surface chemisorbed gases and the amplification role played by the nanowire to Schottky barrier effect, an ultrahigh sensitivity of 32 000% was achieved using the Schottky contacted device operated in reverse bias mode at 275 °C for detection of 400 ppm CO, which is 4 orders of magnitude higher than that obtained using an Ohmic contact device under the same conditions. In addition, the response time and reset time have been shortened by a factor of 7. The methodology and principle illustrated in the paper present a new sensing mechanism that can be readily and extensively applied to other gas sensing systems. © 2009 American Chemical Society.

  9. Gigantic Enhancement in Sensitivity Using Schottky Contacted Nanowire Nanosensor

    KAUST Repository

    Wei, Te-Yu

    2009-12-09

    A new single nanowire based nanosensor is demonstrated for illustrating its ultrahigh sensitivity for gas sensing. The device is composed of a single ZnO nanowire mounted on Pt electrodes with one end in Ohmic contact and the other end in Schottky contact. The Schottky contact functions as a "gate" that controls the current flowing through the entire system. By tuning the Schottky barrier height through the responsive variation of the surface chemisorbed gases and the amplification role played by the nanowire to Schottky barrier effect, an ultrahigh sensitivity of 32 000% was achieved using the Schottky contacted device operated in reverse bias mode at 275 °C for detection of 400 ppm CO, which is 4 orders of magnitude higher than that obtained using an Ohmic contact device under the same conditions. In addition, the response time and reset time have been shortened by a factor of 7. The methodology and principle illustrated in the paper present a new sensing mechanism that can be readily and extensively applied to other gas sensing systems. © 2009 American Chemical Society.

  10. Contextualizing Intergroup Contact: Do Political Party Cues Enhance Contact Effects?

    DEFF Research Database (Denmark)

    Sønderskov, Kim Mannemar; Thomsen, Jens Peter Frølund

    2015-01-01

    This article examines intergroup contact effects in different political contexts. We expand on previous efforts of social psychologists by incorporating the messages of political parties as a contextual trigger of group membership awareness in contact situations. We argue that the focus among...... political parties on us-them categorizations heightens the awareness of group memberships. This focus in turn enhances the positive intergroup contact effect by stimulating majority members to perceive contacted persons as prototypical outgroup members. A multilevel analysis of 22 countries and almost 37......,000 individuals confirms that the ability of intergroup contact to reduce antiforeigner sentiment increases when political parties focus intensively on immigration issues and cultural differences. Specifically, both workplace contact and interethnic friendship become more effective in reducing antiforeigner...

  11. Low resistive edge contacts to CVD-grown graphene using a CMOS compatible metal

    Energy Technology Data Exchange (ETDEWEB)

    Shaygan, Mehrdad; Otto, Martin; Sagade, Abhay A.; Neumaier, Daniel [Advanced Microelectronic Center Aachen, AMO GmbH, Aachen (Germany); Chavarin, Carlos A. [Lehrstuhl Werkstoffe der Elektrotechnik, Duisburg-Essen Univ., Duisburg (Germany); Innovations for High Performance Microelectronics, IHP GmbH, Frankfurt (Oder) (Germany); Bacher, Gerd; Mertin, Wolfgang [Lehrstuhl Werkstoffe der Elektrotechnik, Duisburg-Essen Univ., Duisburg (Germany)

    2017-11-15

    The exploitation of the excellent intrinsic electronic properties of graphene for device applications is hampered by a large contact resistance between the metal and graphene. The formation of edge contacts rather than top contacts is one of the most promising solutions for realizing low ohmic contacts. In this paper the fabrication and characterization of edge contacts to large area CVD-grown monolayer graphene by means of optical lithography using CMOS compatible metals, i.e. Nickel and Aluminum is reported. Extraction of the contact resistance by Transfer Line Method (TLM) as well as the direct measurement using Kelvin Probe Force Microscopy demonstrates a very low width specific contact resistance down to 130 Ωμm. The contact resistance is found to be stable for annealing temperatures up to 150 C enabling further device processing. Using this contact scheme for edge contacts, a field effect transistor based on CVD graphene with a high transconductance of 0.63 mS/μm at 1 V bias voltage is fabricated. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. Simulation and economic analysis of a liquid-based solar system with a direct-contact liquid-liquid heat exchanger, in comparison to a system with a conventional heat exchanger

    Science.gov (United States)

    Brothers, P.; Karaki, S.

    Using a solar computer simulation package called TRNSYS, simulations of the direct contact liquid-liquid heat exchanger (DCLLHE) solar system and a system with conventional shell-and-tube heat exchanger were developed, based in part on performance measurements of the actual systems. The two systems were simulated over a full year on an hour-by-hour basis at five locations; Boston, Massachusetts, Charleston, South Carolina, Dodge City, Kansas, Madison, Wisconsin, and Phoenix, Arizona. Typically the direct-contact system supplies slightly more heat for domestic hot water and space heating in all locations and about 5 percentage points more cooling as compared to the conventional system. Using a common set of economic parameters and the appropriate federal and state income tax credits, as well as property tax legislation for solar systems in the corresponding states, the results of the study indicate for heating-only systems, the DCLLHE system has a slight life-cycle cost disadvantage compared to the conventional system. For combined solar heating and cooling systems, the DCLLHE has a slight life-cycle cost advantage which varies with location and amounts to one to three percent difference from the conventional system.

  13. Rapid, Time-Division Multiplexed, Direct Absorption- and Wavelength Modulation-Spectroscopy

    Directory of Open Access Journals (Sweden)

    Alexander Klein

    2014-11-01

    Full Text Available We present a tunable diode laser spectrometer with a novel, rapid time multiplexed direct absorption- and wavelength modulation-spectroscopy operation mode. The new technique allows enhancing the precision and dynamic range of a tunable diode laser absorption spectrometer without sacrificing accuracy. The spectroscopic technique combines the benefits of absolute concentration measurements using calibration-free direct tunable diode laser absorption spectroscopy (dTDLAS with the enhanced noise rejection of wavelength modulation spectroscopy (WMS. In this work we demonstrate for the first time a 125 Hz time division multiplexed (TDM-dTDLAS-WMS spectroscopic scheme by alternating the modulation of a DFB-laser between a triangle-ramp (dTDLAS and an additional 20 kHz sinusoidal modulation (WMS. The absolute concentration measurement via the dTDLAS-technique allows one to simultaneously calibrate the normalized 2f/1f-signal of the WMS-technique. A dTDLAS/WMS-spectrometer at 1.37 µm for H2O detection was built for experimental validation of the multiplexing scheme over a concentration range from 50 to 3000 ppmV (0.1 MPa, 293 K. A precision of 190 ppbV was achieved with an absorption length of 12.7 cm and an averaging time of two seconds. Our results show a five-fold improvement in precision over the entire concentration range and a significantly decreased averaging time of the spectrometer.

  14. Study of gas-solid contact in an ultra-rapid reactor for cumene catalytic cracking; Etude du contact gaz-solide dans un reacteur a co-courant descendant par la mise en oeuvre du craquage catalytique du cumene

    Energy Technology Data Exchange (ETDEWEB)

    Bayle, J

    1996-11-05

    Few studies have been carried out on the notion of gas-solid contact in ultra-rapid reactors. Both gas and solid move in the reactor and the contact can be directly estimated when using a chemical reaction such as cumene cracking. It`s a pure and light feedstock whose kinetics can be determined in a fixed bed. The study was carried out on a downflow ultra-rapid reactor (ID = 20 mm, length = 1 m) at the University of Western Ontario. It proved that the quench and the ultra-rapid separation of gas and solid must be carefully designed in the pilot plant. Cumene conversion dropped when reducing gas-solid contact, which led to push the temperature over 550 deg. C and increase the cat/oil ratio at 25 working at solid mass fluxes below 85 kg/m{sup 2}.s. Change of selectivity at very short residence time were also observed due to deactivation effects. Experiments made by Roques (1994) with phosphorescent pigments on the Residence Time Distribution of solids gave Hydrodynamic data on a cold flow copy of the pilot plant. Experiments made on packed bed gave kinetic data on the cracking of cumene. These data were combined to optimize a mono dimensional plug flow model for cumene cracking. (author)

  15. Secondary transfer effects of interracial contact: the moderating role of social status.

    Science.gov (United States)

    Bowman, Nicholas A; Griffin, Tiffany M

    2012-01-01

    The contact hypothesis asserts that intergroup attitudes can be improved when groups have opportunities to interact with each other. Recent research extending the contact hypothesis suggests that contact with a primary outgroup can decrease bias toward outgroups not directly involved in the interaction, which is known as the secondary transfer effect (STE). The present study contributes to growing research on STEs by investigating effects among Asian, Black, Hispanic, and White undergraduate students (N = 3,098) attending 28 selective colleges and universities. Using hierarchical linear modeling, our results reveal numerous positive STEs among Asian, Black, and Hispanic college students. No significant STEs were observed among White students. Mediated moderation analyses support an attitude generalization mechanism, because STEs were explained by changes in attitudes toward the primary outgroup. This research speaks to equivocal findings in the extant STE literature and highlights directions for future research on social cohesion and bias reduction.

  16. Direct measurements of air layer profiles under impacting droplets using high-speed color interferometry

    NARCIS (Netherlands)

    van der Veen, Roeland; Tran, Tuan; Lohse, Detlef; Sun, Chao

    2012-01-01

    A drop impacting on a solid surface deforms before the liquid makes contact with the surface. We directly measure the time evolution of the air layer profile under the droplet using high-speed color interferometry, obtaining the air layer thickness before and during the wetting process. Based on the

  17. Non-contact finger vein acquisition system using NIR laser

    Science.gov (United States)

    Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan

    2009-02-01

    Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.

  18. Effect of Tabor parameter on hysteresis losses during adhesive contact

    Science.gov (United States)

    Ciavarella, M.; Greenwood, J. A.; Barber, J. R.

    2017-01-01

    The Tabor parameter μ is conventionally assumed to determine the range of applicability of the classical 'JKR' solution for adhesive elastic contact of a sphere and a plane, with the variation of the contact area and approach with load, and in particular the maximum tensile force (the pull-off force) being well predicted for μ > 5 . Here we show that the hysteretic energy loss during a contact separation cycle is significantly overestimated by the JKR theory, even at quite large values of μ. This stems from the absence of long-range tensile forces in the JKR theory, which implies that jump into contact is delayed until the separation α = 0 . We develop an approximate solution based on the use of Wu's solution with van der Waals interactions for jump-in, and the JKR theory for jump out of contact, and show that for μ > 5 , the predicted hysteresis loss is then close to that found by direct numerical solutions using the Lennard-Jones force law. We also show how the same method can be adapted to allow for contact between bodies with finite support stiffness.

  19. Strong normalization by type-directed partial evaluation and run-time code generation

    DEFF Research Database (Denmark)

    Balat, Vincent; Danvy, Olivier

    1998-01-01

    We investigate the synergy between type-directed partial evaluation and run-time code generation for the Caml dialect of ML. Type-directed partial evaluation maps simply typed, closed Caml values to a representation of their long βη-normal form. Caml uses a virtual machine and has the capability...... to load byte code at run time. Representing the long βη-normal forms as byte code gives us the ability to strongly normalize higher-order values (i.e., weak head normal forms in ML), to compile the resulting strong normal forms into byte code, and to load this byte code all in one go, at run time. We...... conclude this note with a preview of our current work on scaling up strong normalization by run-time code generation to the Caml module language....

  20. Strong Normalization by Type-Directed Partial Evaluation and Run-Time Code Generation

    DEFF Research Database (Denmark)

    Balat, Vincent; Danvy, Olivier

    1997-01-01

    We investigate the synergy between type-directed partial evaluation and run-time code generation for the Caml dialect of ML. Type-directed partial evaluation maps simply typed, closed Caml values to a representation of their long βη-normal form. Caml uses a virtual machine and has the capability...... to load byte code at run time. Representing the long βη-normal forms as byte code gives us the ability to strongly normalize higher-order values (i.e., weak head normal forms in ML), to compile the resulting strong normal forms into byte code, and to load this byte code all in one go, at run time. We...... conclude this note with a preview of our current work on scaling up strong normalization by run-time code generation to the Caml module language....

  1. Investigating the Relationship Between Self-Directed Learning Readiness and Time Management Skills in Turkish Undergraduate Nursing Students.

    Science.gov (United States)

    Ertuğ, Nurcan; Faydali, Saide

    The aims of this study were to determine self-directed learning and time management skills of undergraduate nursing students and to investigate the relationship between the concepts. The use of self-directed learning has increased as an educational strategy in recent years. This descriptive and correlational study was conducted with 383 undergraduate nursing students in Turkey. Data were collected using a sociodemographic questionnaire, the Self-Directed Learning Readiness Scale, and Time Management Questionnaire. Mean scores were as follows: self-directed learning readiness, 159.12 (SD = 20.8); time management, 87.75 (SD = 12.1). A moderate positive correlation was found between self-directed learning readiness and time management values. Time management scores were 78.42 when self-directed learning readiness was ≤149 and 90.82 when self-directed learning readiness was ≥ 150, with a statistically significant difference (p = .000). Level of self-directed learning and academic achievement were higher in students who managed their time well.

  2. Contact allergy to the 26 specific fragrance ingredients to be declared on cosmetic products in accordance with the EU cosmetics directive.

    Science.gov (United States)

    Heisterberg, Maria V; Menné, Torkil; Johansen, Jeanne D

    2011-11-01

    Fragrance ingredients are a frequent cause of allergic contact dermatitis. The EU Cosmetics Directive states that 26 specific fragrance ingredients, known to cause allergic contact dermatitis, must be declared on the ingredient lists of cosmetic products. To investigate frequencies of sensitization to the 26 individual fragrances and evaluate their importance as screening markers of fragrance allergy. This was a retrospective study based on data from the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte. Eczema patients (n = 1508) were patch tested (January 2008 to July 2010) with the 26 fragrance ingredients. Sensitization to the 26 fragrances was identified in 115 (7.6%) subjects. The most frequent allergens were Evernia furfuracea (n = 50), Evernia prunastri (n = 31), and hydroxyisohexyl 3-cyclohexene carboxaldehyde (n = 24). Including fragrance mix I, fragrance mix II and Myroxylon pereirae, 196 (13.0%) had a fragrance allergy. Testing with the 26 fragrances additionally identified 23 subjects who would otherwise have gone undetected. The majority (75.7%) of positive reactions to the 26 fragrances were of clinical relevance. Sensitization to the 26 individual fragrance ingredients was identified in 7.6% of the subjects patch tested. Most reactions were of clinical relevance. Fragrance-allergic subjects would be missed if testing with the individual fragrance ingredients was not performed. © 2011 John Wiley & Sons A/S.

  3. Enhanced Contact Graph Routing (ECGR) MACHETE Simulation Model

    Science.gov (United States)

    Segui, John S.; Jennings, Esther H.; Clare, Loren P.

    2013-01-01

    Contact Graph Routing (CGR) for Delay/Disruption Tolerant Networking (DTN) space-based networks makes use of the predictable nature of node contacts to make real-time routing decisions given unpredictable traffic patterns. The contact graph will have been disseminated to all nodes before the start of route computation. CGR was designed for space-based networking environments where future contact plans are known or are independently computable (e.g., using known orbital dynamics). For each data item (known as a bundle in DTN), a node independently performs route selection by examining possible paths to the destination. Route computation could conceivably run thousands of times a second, so computational load is important. This work refers to the simulation software model of Enhanced Contact Graph Routing (ECGR) for DTN Bundle Protocol in JPL's MACHETE simulation tool. The simulation model was used for performance analysis of CGR and led to several performance enhancements. The simulation model was used to demonstrate the improvements of ECGR over CGR as well as other routing methods in space network scenarios. ECGR moved to using earliest arrival time because it is a global monotonically increasing metric that guarantees the safety properties needed for the solution's correctness since route re-computation occurs at each node to accommodate unpredicted changes (e.g., traffic pattern, link quality). Furthermore, using earliest arrival time enabled the use of the standard Dijkstra algorithm for path selection. The Dijkstra algorithm for path selection has a well-known inexpensive computational cost. These enhancements have been integrated into the open source CGR implementation. The ECGR model is also useful for route metric experimentation and comparisons with other DTN routing protocols particularly when combined with MACHETE's space networking models and Delay Tolerant Link State Routing (DTLSR) model.

  4. Universality in dynamic wetting dominated by contact-line friction.

    Science.gov (United States)

    Carlson, Andreas; Bellani, Gabriele; Amberg, Gustav

    2012-04-01

    We report experiments on the rapid contact-line motion present in the early stages of capillary-driven spreading of drops on dry solid substrates. The spreading data fail to follow a conventional viscous or inertial scaling. By integrating experiments and simulations, we quantify a contact-line friction μ(f) which is seen to limit the speed of the rapid dynamic wetting. A scaling based on this contact-line friction is shown to yield a universal curve for the evolution of the contact-line radius as a function of time, for a range of fluid viscosities, drop sizes, and surface wettabilities.

  5. Holding the baby: early mother-infant contact after childbirth and outcomes.

    Science.gov (United States)

    Redshaw, Maggie; Hennegan, Julie; Kruske, Sue

    2014-05-01

    to describe the timing, type and duration of initial infant contact and associated demographic and clinical factors in addition to investigating the impact of early contact on breastfeeding and maternal health and well being after birth. data from a recent population survey of women birthing in Queensland, Australia were used to describe the nature of the first hold and associated demographic characteristics. Initial comparisons, with subsequent adjustment for type of birthing facility and mode of childbirth, were used to assess associations between timing, type and duration of initial contact and outcomes. Further analyses were conducted to investigate a dose-response relationship between duration of first contact and outcomes. women who had an unassisted vaginal birth held their infant sooner, and for longer than women who had an assisted vaginal birth or caesarean and were more satisfied with their early contact. Multivariate models showed a number of demographic and clinical interventions contributing to timing, duration and type of first contact with type of birthing facility (public/private), area of residence, and assisted birth as prominent factors. For women who had a vaginal birth; early, skin-to-skin, and longer duration of initial contact were associated with high rates of breastfeeding initiation and breastfeeding at discharge, but not breastfeeding at 13 weeks. Some aspects of early contact were associated with improved maternal well being. However, these associations were not found for women who had a caesarean birth. With longer durations of first contact, a dose-response effect was found for breastfeeding. results of the study provide a description of current practice in Queensland, Australia and factors impacting on early contact. For vaginal births, findings add to the evidence in support of early skin-to-skin contact for an extended period. It is suggested that all research in this area should consider the effects of early contact separately for

  6. The effect of scapular position on subacromial contact behavior: a cadaver study.

    Science.gov (United States)

    Muraki, Takayuki; Yamamoto, Nobuyuki; Sperling, John W; Steinmann, Scott P; Cofield, Robert H; An, Kai-Nan

    2017-05-01

    Patients with subacromial impingement were reported to show abnormal scapular positions during shoulder elevation. However, the relationship between the scapular positions and subacromial impingement is unclear. The purpose of this study was to biomechanically determine the effect of scapular position on subacromial contact behavior by using fresh frozen cadavers. The peak contact pressure on the coracoacromial arch was measured with a flexible tactile force sensor in 9 fresh frozen cadaver shoulders. The measurement was performed during passive glenohumeral elevation in the scapular plane ranging from 30° to 75°. The scapular downward and internal rotations and anterior tilt were simulated by tilting the scapula in 5° increments up to 20°. The measurement was also performed with combination of scapular downward and internal rotations and anterior tilt positions. The peak contact pressure decreased linearly with anterior tilt, and a significant difference between neutral scapular position (1.06 ± 0.89 MPa) and anterior tilt by 20° (0.46 ± 0.18 MPa) was observed (P < .05). However, the scapular positioning in the other directions did not change the peak contact pressure significantly. Furthermore, any combination of abnormal scapular positions did not affect peak contact pressure significantly. Scapular anterior tilt decreased peak contact pressure during passive shoulder elevation. In addition, scapular downward and internal rotations had little effect on peak contact pressure. The abnormal scapular motion reported in previous studies might not be directly related to symptoms caused by subacromial impingement. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. A DTN-ready application for the real-time dissemination of Earth Observation data received by Direct Readout stations

    Science.gov (United States)

    Paronis, Dimitris; Daglis, Ioannis A.; Diamantopoulos, Sotirios; Tsaoussidis, Vassilis; Tsigkanos, Antonis; Ghita, Bogdan; Evans, Michael

    2014-05-01

    The majority of Earth observation satellites operate in low Earth sun-synchronous orbit and transmit data captured by a variety of sensors. The effective dissemination of satellite data in real-time is a crucial parameter for disaster monitoring in particular. Generally, a spacecraft collects data and then stores it on-board until it passes over dedicated ground stations to transmit the data. Additionally, some satellites (e.g. Terra, Aqua, Suomi-NPP, NOAA series satellites) have the so-called Direct Broadcast (DB) capability, which is based on a real-time data transmission sub-system. Compatible Direct Readout (DR) stations in direct line of sight are able to receive these transmissions. To date data exchange between DR stations have not been fully exploited for real-time data dissemination. Stations around the world store data locally, which is then disseminated on demand via Internet gateways based on the standard TCP-IP protocols. On the other hand, Delay Tolerant Networks (DTNs), which deliver data by enabling store-and-forward transmission in order to cope with link failures, service disruptions and network congestion, could prove as an alternative/complementary transmission mechanism for the efficient dissemination of data. The DTN architecture allows for efficient utilization of the network, using in-network storage and taking advantage of the network availability among the interconnected nodes. Although DTNs were originally developed for high-propagation delay, challenged connectivity environments such as deep space, the broader research community has investigated possible architectural enhancements for various emerging applications (e.g., terrestrial infrastructure, ground-to-air communications, content retrieval and dissemination). In this paper, a scheme for the effective dissemination of DB data is conceptualized, designed and implemented based on store-and-forward transmission capabilities provided by DTNs. For demonstration purposes, a set-up has

  8. Direct methods for limit states in structures and materials

    CERN Document Server

    Weichert, Dieter

    2014-01-01

    Knowing the safety factor for limit states such as plastic collapse, low cycle fatigue or ratcheting is always a major design consideration for civil and mechanical engineering structures that are subjected to loads. Direct methods of limit or shakedown analysis that proceed to directly find the limit states offer a better alternative than exact time-stepping calculations as, on one hand, an exact loading history is scarcely known, and on the other they are much less time-consuming. This book presents the state of the art on various topics concerning these methods, such as theoretical advances in limit and shakedown analysis, the development of relevant algorithms and computational procedures, sophisticated modeling of inelastic material behavior like hardening, non-associated flow rules, material damage and fatigue, contact and friction, homogenization and composites.

  9. Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Meltem Önder

    2009-03-01

    Full Text Available Allergic contact dermatitis is the delayed type hypersensitivity reaction to exogenous agents. Allergic contact dermatitis may clinically present acutely after allergen exposure and initial sensitization in a previously sensitized individual. Acute phase is characterized by erythematous, scaly plaques. In severe cases vesiculation and bullae in exposed areas are very characteristic. Repeated or continuous exposure of sensitized individual with allergen result in chronic dermatitis. Lichenification, erythematous plaques, hyperkeratosis and fissuring may develop in chronic patients. Allergic contact dermatitis is very common dermatologic problem in dermatology daily practice. A diagnosis of contact dermatitis requires the careful consideration of patient history, physical examination and patch testing. The knowledge of the clinical features of the skin reactions to various contactans is important to make a correct diagnosis of contact dermatitis. It can be seen in every age, in children textile product, accessories and touch products are common allergens, while in adults allergic contact dermatitis may be related with topical medicaments. The contact pattern of contact dermatitis depends on fashion and local traditions as well. The localization of allergic reaction should be evaluated and patients’ occupation and hobbies should be asked. The purpose of this review is to introduce to our collaques up dated allergic contact dermatitis literatures both in Turkey and in the World.

  10. Toxicological evaluation of liquids proposed for use in direct contact liquid--liquid heat exchangers for solar heated and cooled buildings

    Energy Technology Data Exchange (ETDEWEB)

    Buchan, R.M.; Majestic, J.R.; Billau, R.

    1976-09-01

    This report contains the results of the toxicological evaluation part of the project entitled, ''Direct Contact Liquid-Liquid Heat Exchangers for Solar Heated and Cooled Buildings.'' Obviously any liquid otherwise suitable for use in such a device should be subjected to a toxicological evaluation. 34 liquids (24 denser than water, 10 less dense) have physical and chemical properties that would make them suitable for use in such a device. In addition to the complexity involved in selecting the most promising liquids from the standpoint of their chemical and physical properties is added the additional difficulty of also considering their toxicological properties. Some of the physical and chemical properties of these liquids are listed. The liquids are listed in alphabetical order within groups, the denser than water liquids are listed first followed by those liquids less dense than water.

  11. Elastic-properties measurement at high temperatures through contact resonance atomic force microscopy

    DEFF Research Database (Denmark)

    Marinello, Francesco; Pezzuolo, Andrea; Carmignato, Simone

    2015-01-01

    fast direct and non-destructive measurement of Young's modulus and related surface parameters.In this work an instrument set up for Contact Resonance Atomic Force Microscopy is proposed, where the sample with is coupled to a heating stage and a piezoelectric transducer directly vibrate the cantilever...

  12. Achieving timely percutaneous reperfusion for rural ST-elevation myocardial infarction patients by direct transport to an urban PCI-hospital.

    Science.gov (United States)

    Bennin, Charles-Lwanga K; Ibrahim, Saif; Al-Saffar, Farah; Box, Lyndon C; Strom, Joel A

    2016-10-01

    ST-elevation myocardial infarction (STEMI) guidelines recommend reperfusion by primary percutaneous coronary intervention (PCI) ≤ 90 min from time of first medical contact (FMC). This strategy is challenging in rural areas lacking a nearby PCI-capable hospital. Recommended reperfusion times can be achieved for STEMI patients presenting in rural areas without a nearby PCI-capable hospital by ground transportation to a central PCI-capable hospital by use of protocol-driven emergency medical service (EMS) STEMI field triage protocol. Sixty STEMI patients directly transported by EMS from three rural counties (Nassau, Camden and Charlton Counties) within a 50-mile radius of University of Florida Health-Jacksonville (UFHJ) from 01/01/2009 to 12/31/2013 were identified from its PCI registry. The STEMI field triage protocol incorporated three elements: (1) a cooperative agreement between each of the rural emergency medical service (EMS) agency and UFHJ; (2) performance of a pre-hospital ECG to facilitate STEMI identification and laboratory activation; and (3) direct transfer by ground transportation to the UFHJ cardiac catheterization laboratory. FMC-to-device (FMC2D), door-to-device (D2D), and transit times, the day of week, time of day, and EMS shift times were recorded, and odds ratio (OR) of achieving FMC2D times was calculated. FMC2D times were shorter for in-state STEMIs (81 ± 17 vs . 87 ± 19 min), but D2D times were similar (37 ± 18 vs . 39 ± 21 min). FMC2D ≤ 90 min were achieved in 82.7% in-state STEMIs compared to 52.2% for out-of-state STEMIs (OR = 4.4, 95% CI: 1.24-15.57; P = 0.018). FMC2D times were homogenous after adjusting for weekday vs . weekend, EMS shift times. Nine patients did not meet FMC2D ≤ 90 min. Six were within 10 min of target; all patient achieved FMC2D ≤ 120 min. Guideline-compliant FMC2D ≤ 90 min is achievable for rural STEMI patients within a 50 mile radius of a PCI-capable hospital by use of protocol-driven EMS ground

  13. Contact stresses by rounded punch subject to axial and transverse shear

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Kyu [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1999-05-01

    Contact shear stresses by rounded punch were evaluated numerically. Numerical program was successfully implemented by using an influence function method. To simulate the physical fretting problem, a closed load path of shear was considered. The influence functions on surface displacements fo both axial and transverse direction were calculated using a triangular shear traction element. Behaviour of the contact surface, such as stick and slip region during the load path was investigated together with compliance change. Irreversibility of the shear stress was shown. The importance and the utilization of the present research were discussed for analyzing the material failure induced by contact such as fretting wear and fatigue.

  14. Contact stresses by rounded punch subject to axial and transverse shear

    International Nuclear Information System (INIS)

    Kim, Hyung Kyu

    1999-01-01

    Contact shear stresses by rounded punch were evaluated numerically. Numerical program was successfully implemented by using an influence function method. To simulate the physical fretting problem, a closed load path of shear was considered. The influence functions on surface displacements fo both axial and transverse direction were calculated using a triangular shear traction element. Behaviour of the contact surface, such as stick and slip region during the load path was investigated together with compliance change. Irreversibility of the shear stress was shown. The importance and the utilization of the present research were discussed for analyzing the material failure induced by contact such as fretting wear and fatigue

  15. Refining intra-protein contact prediction by graph analysis

    Directory of Open Access Journals (Sweden)

    Eyal Eran

    2007-05-01

    Full Text Available Abstract Background Accurate prediction of intra-protein residue contacts from sequence information will allow the prediction of protein structures. Basic predictions of such specific contacts can be further refined by jointly analyzing predicted contacts, and by adding information on the relative positions of contacts in the protein primary sequence. Results We introduce a method for graph analysis refinement of intra-protein contacts, termed GARP. Our previously presented intra-contact prediction method by means of pair-to-pair substitution matrix (P2PConPred was used to test the GARP method. In our approach, the top contact predictions obtained by a basic prediction method were used as edges to create a weighted graph. The edges were scored by a mutual clustering coefficient that identifies highly connected graph regions, and by the density of edges between the sequence regions of the edge nodes. A test set of 57 proteins with known structures was used to determine contacts. GARP improves the accuracy of the P2PConPred basic prediction method in whole proteins from 12% to 18%. Conclusion Using a simple approach we increased the contact prediction accuracy of a basic method by 1.5 times. Our graph approach is simple to implement, can be used with various basic prediction methods, and can provide input for further downstream analyses.

  16. Direct Cell-Cell Contact between Mesenchymal Stem Cells and Endothelial Progenitor Cells Induces a Pericyte-Like Phenotype In Vitro

    Directory of Open Access Journals (Sweden)

    Markus Loibl

    2014-01-01

    Full Text Available Tissue engineering techniques for the regeneration of large bone defects require sufficient vascularisation of the applied constructs to ensure a sufficient supply of oxygen and nutrients. In our previous work, prevascularised 3D scaffolds have been successfully established by coculture of bone marrow derived stem cells (MSCs and endothelial progenitor cells (EPCs. We identified stabilising pericytes (PCs as part of newly formed capillary-like structures. In the present study, we report preliminary data on the interactions between MSCs and EPCs, leading to the differentiation of pericyte-like cells. MSCs and EPCs were seeded in transwell cultures, direct cocultures, and single cultures. Cells were cultured for 10 days in IMDM 10% FCS or IMDM 5% FCS 5% platelet lysate medium. Gene expression of PC markers, CD146, NG2, αSMA, and PDGFR-β, was analysed using RT-PCR at days 0, 3, 7, and 10. The upregulation of CD146, NG2, and αSMA in MSCs in direct coculture with EPCs advocates the MSCs’ differentiation towards a pericyte-like phenotype in vitro. These results suggest that pericyte-like cells derive from MSCs and that cell-cell contact with EPCs is an important factor for this differentiation process. These findings emphasise the concept of coculture strategies to promote angiogenesis for cell-based tissue engineered bone grafts.

  17. Dynamic Model of Contact Interface between Stator and Rotor

    Directory of Open Access Journals (Sweden)

    ZengHui Zhao

    2013-01-01

    Full Text Available Based on the equivalent principle, a linear spring contact model was established for the friction layer between stator and rotor. Different contact conditions were described by a distance index δ. Detailed analysis of the nonlinear contact behavior especially the static and dynamic slipping was carried on using a space-time equation. A contact deflection angle was proposed to quantitatively express the influence of friction force on the output performance. A more precision simulation model was established based on the theoretical analysis, and influences of different preload pressures and elastic modulus Em of friction layer on output performance were analyzed. The results showed the simulation results had very good consistency with experimental results, and the model could well reflect the output characteristics of contact interface.

  18. Mind the Organelle Gap - Peroxisome Contact Sites in Disease.

    Science.gov (United States)

    Castro, Inês Gomes; Schuldiner, Maya; Zalckvar, Einat

    2018-03-01

    The eukaryotic cell is organized as a complex grid system where membrane-bound cellular compartments, organelles, must be localized to the right place at the right time. One way to facilitate correct organelle localization and organelle cooperation is through membrane contact sites, areas of close proximity between two organelles that are bridged by protein/lipid complexes. It is now clear that all organelles physically contact each other. The main focus of this review is contact sites of peroxisomes, central metabolic hubs whose defects lead to a variety of diseases. New peroxisome contacts, their tethering complexes and functions have been recently discovered. However, if and how peroxisome contacts contribute to the development of peroxisome-related diseases is still a mystery. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Ground Contact Analysis for Korea’s Fictitious Lunar Orbiter Mission

    Directory of Open Access Journals (Sweden)

    Young-Joo Song

    2013-12-01

    Full Text Available In this research, the ground contact opportunity for the fictitious low lunar orbiter is analyzed to prepare for a future Korean lunar orbiter mission. The ground contact opportunity is basically derived from geometrical relations between the typical ground stations at the Earth, the relative positions of the Earth and Moon, and finally, the lunar orbiter itself. Both the cut-off angle and the orbiter’s Line of Sight (LOS conditions (weather orbiter is located at near or far side of the Moon seen from the Earth are considered to determine the ground contact opportunities. Four KOMPSAT Ground Stations (KGSs are assumed to be Korea’s future Near Earth Networks (NENs to support lunar missions, and world-wide separated Deep Space Networks (DSNs are also included during the contact availability analysis. As a result, it is concluded that about 138 times of contact will be made between the orbiter and the Daejeon station during 27.3 days of prediction time span. If these contact times are converted into contact duration, the duration is found to be about 8.55 days, about 31.31% of 27.3 days. It is discovered that selected four KGSs cannot provide continuous tracking of the lunar orbiter, meaning that international collaboration is necessary to track Korea’s future lunar orbiter effectively. Possible combinations of world-wide separated DSNs are also suggested to compensate for the lack of contact availability with only four KGSs, as with primary and backup station concepts. The provided algorithm can be easily modified to support any type of orbit around the Moon, and therefore, the presented results could aid further progress in the design field of Korea’s lunar orbiter missions.

  20. Optimization of Removal Efficiency and Minimum Contact Time for Cadmium and Zinc Removal onto Iron-modified Zeolite in a Two-stage Batch Sorption Reactor

    Directory of Open Access Journals (Sweden)

    M. Ugrina

    2018-01-01

    Full Text Available In highly congested industrial sites where significant volumes of effluents have to be treated in the minimum contact time, the application of a multi-stage batch reactor is suggested. To achieve better balance between capacity utilization and cost efficiency in design optimization, a two-stage batch reactor is usually the optimal solution. Thus, in this paper, a two-stage batch sorption design approach was applied to the experimental data of cadmium and zinc uptake onto iron-modified zeolite. The optimization approach involves the application of the Vermeulen’s approximation model and mass balance equation to kinetic data. A design analysis method was developed to optimize the removal efficiency and minimum total contact time by combining the time required in the two-stages, in order to achieve the maximum percentage of cadmium and zinc removal using a fixed mass of zeolite. The benefits and limitations of the two-stage design approach have been investigated and discussed