WorldWideScience

Sample records for contact sensitizing chemicals

  1. Association between atopic dermatitis and contact sensitization

    DEFF Research Database (Denmark)

    Hamann, Carsten R; Hamann, Dathan; Egeberg, Alexander

    2017-01-01

    BACKGROUND: It is unclear whether patients with atopic dermatitis (AD) have an altered prevalence or risk for contact sensitization. Increased exposure to chemicals in topical products together with impaired skin barrier function suggest a higher risk, whereas the immune profile suggests a lower...... contact dermatitis is suspected....... risk. OBJECTIVE: To perform a systematic review and meta-analysis of the association between AD and contact sensitization. METHODS: The PubMed/Medline, Embase, and Cochrane databases were searched for articles that reported on contact sensitization in individuals with and without AD. RESULTS...

  2. Prediction of the contact sensitizing potential of chemicals using analysis of gene expression changes in human THP-1 monocytes.

    Science.gov (United States)

    Arkusz, Joanna; Stępnik, Maciej; Sobala, Wojciech; Dastych, Jarosław

    2010-11-10

    The aim of this study was to find differentially regulated genes in THP-1 monocytic cells exposed to sensitizers and nonsensitizers and to investigate if such genes could be reliable markers for an in vitro predictive method for the identification of skin sensitizing chemicals. Changes in expression of 35 genes in the THP-1 cell line following treatment with chemicals of different sensitizing potential (from nonsensitizers to extreme sensitizers) were assessed using real-time PCR. Verification of 13 candidate genes by testing a large number of chemicals (an additional 22 sensitizers and 8 nonsensitizers) revealed that prediction of contact sensitization potential was possible based on evaluation of changes in three genes: IL8, HMOX1 and PAIMP1. In total, changes in expression of these genes allowed correct detection of sensitization potential of 21 out of 27 (78%) test sensitizers. The gene expression levels inside potency groups varied and did not allow estimation of sensitization potency of test chemicals. Results of this study indicate that evaluation of changes in expression of proposed biomarkers in THP-1 cells could be a valuable model for preliminary screening of chemicals to discriminate an appreciable majority of sensitizers from nonsensitizers. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  3. Contact sensitization to common haptens is associated with atopic dermatitis: new insight

    DEFF Research Database (Denmark)

    Thyssen, J P; Linneberg, A; Engkilde, K

    2012-01-01

    and questioned about AD Results: The variable "contact sensitization to common chemicals, but not nickel and thimerosal", was significantly associated with atopic dermatitis (OR=2.53; CI95%=1.59-4.04). The higher prevalence of contact sensitization was mainly driven by fragrance chemicals. In a sub......-analysis in non-pierced women, a positive association was also found for nickel sensitization. Nickel and thimerosal sensitization may introduce bias in data analysis since these allergies often develop following skin piercing where the skin compartments are bypassed. Discussion: We suspect that individuals...

  4. Identification of contact and respiratory sensitizers according to IL-4 receptor α expression and IL-2 production

    Energy Technology Data Exchange (ETDEWEB)

    Goutet, Michèle, E-mail: michele.goutet@inrs.fr; Pépin, Elsa; Langonné, Isabelle; Huguet, Nelly; Ban, Masarin

    2012-04-15

    Identification of allergenic chemicals is an important occupational safety issue. While several methods exist to identify contact sensitizers, there is currently no validated model to predict the potential of chemicals to act as respiratory sensitizers. Previously, we reported that cytometry analysis of the local immune responses induced in mice dermally exposed to the respiratory sensitizer trimellitic anhydride (TMA 10%) and contact sensitizer dinitrochlorobenzene (DNCB 1%) could identify divergent expression of several immune parameters. The present study confirms, first, that IgE-positive B cells, MHC class II molecules, interleukin (IL)-2, IL-4 and IL-4Rα can differentiate the allergic reactions caused by high doses of strong respiratory (TMA, phthalic anhydride and toluene diisocyanate) and contact sensitizers (DNCB, dinitrofluorobenzene and oxazolone). The second part of the study was designed to test the robustness of these markers when classing the weakly immunogenic chemicals most often encountered. Six respiratory allergens, including TMA (2.5%), five contact allergens, including DNCB (0.25%), and two irritants were compared at doses of equivalent immunogenicity. The results indicated that IL-4Rα and IL-2 can be reliably used to discriminate sensitizers. Respiratory sensitizers induced markedly higher IL-4Rα levels than contact allergens, while irritants had no effect on this parameter. Inversely, contact allergens tended to induce higher percentages of IL-2{sup +}CD8{sup +} cells than respiratory allergens. In contrast, the markers MHC-II, IgE and IL-4 were not able to classify chemicals with low immunogenic potential. In conclusion, IL-4Rα and IL-2 have the potential to be used in classifying a variety of chemical allergens. -- Highlights: ► Identification of chemical allergens is an important occupational safety issue. ► There is currently no model to predict the potential of chemicals to induce asthma. ► We analyze immune responses induced

  5. Identification of contact and respiratory sensitizers according to IL-4 receptor α expression and IL-2 production

    International Nuclear Information System (INIS)

    Goutet, Michèle; Pépin, Elsa; Langonné, Isabelle; Huguet, Nelly; Ban, Masarin

    2012-01-01

    Identification of allergenic chemicals is an important occupational safety issue. While several methods exist to identify contact sensitizers, there is currently no validated model to predict the potential of chemicals to act as respiratory sensitizers. Previously, we reported that cytometry analysis of the local immune responses induced in mice dermally exposed to the respiratory sensitizer trimellitic anhydride (TMA 10%) and contact sensitizer dinitrochlorobenzene (DNCB 1%) could identify divergent expression of several immune parameters. The present study confirms, first, that IgE-positive B cells, MHC class II molecules, interleukin (IL)-2, IL-4 and IL-4Rα can differentiate the allergic reactions caused by high doses of strong respiratory (TMA, phthalic anhydride and toluene diisocyanate) and contact sensitizers (DNCB, dinitrofluorobenzene and oxazolone). The second part of the study was designed to test the robustness of these markers when classing the weakly immunogenic chemicals most often encountered. Six respiratory allergens, including TMA (2.5%), five contact allergens, including DNCB (0.25%), and two irritants were compared at doses of equivalent immunogenicity. The results indicated that IL-4Rα and IL-2 can be reliably used to discriminate sensitizers. Respiratory sensitizers induced markedly higher IL-4Rα levels than contact allergens, while irritants had no effect on this parameter. Inversely, contact allergens tended to induce higher percentages of IL-2 + CD8 + cells than respiratory allergens. In contrast, the markers MHC-II, IgE and IL-4 were not able to classify chemicals with low immunogenic potential. In conclusion, IL-4Rα and IL-2 have the potential to be used in classifying a variety of chemical allergens. -- Highlights: ► Identification of chemical allergens is an important occupational safety issue. ► There is currently no model to predict the potential of chemicals to induce asthma. ► We analyze immune responses induced in mice

  6. Gigantic Enhancement in Sensitivity Using Schottky Contacted Nanowire Nanosensor

    KAUST Repository

    Wei, Te-Yu; Yeh, Ping-Hung; Lu, Shih-Yuan; Wang, Zhong Lin

    2009-01-01

    A new single nanowire based nanosensor is demonstrated for illustrating its ultrahigh sensitivity for gas sensing. The device is composed of a single ZnO nanowire mounted on Pt electrodes with one end in Ohmic contact and the other end in Schottky contact. The Schottky contact functions as a "gate" that controls the current flowing through the entire system. By tuning the Schottky barrier height through the responsive variation of the surface chemisorbed gases and the amplification role played by the nanowire to Schottky barrier effect, an ultrahigh sensitivity of 32 000% was achieved using the Schottky contacted device operated in reverse bias mode at 275 °C for detection of 400 ppm CO, which is 4 orders of magnitude higher than that obtained using an Ohmic contact device under the same conditions. In addition, the response time and reset time have been shortened by a factor of 7. The methodology and principle illustrated in the paper present a new sensing mechanism that can be readily and extensively applied to other gas sensing systems. © 2009 American Chemical Society.

  7. Gigantic Enhancement in Sensitivity Using Schottky Contacted Nanowire Nanosensor

    KAUST Repository

    Wei, Te-Yu

    2009-12-09

    A new single nanowire based nanosensor is demonstrated for illustrating its ultrahigh sensitivity for gas sensing. The device is composed of a single ZnO nanowire mounted on Pt electrodes with one end in Ohmic contact and the other end in Schottky contact. The Schottky contact functions as a "gate" that controls the current flowing through the entire system. By tuning the Schottky barrier height through the responsive variation of the surface chemisorbed gases and the amplification role played by the nanowire to Schottky barrier effect, an ultrahigh sensitivity of 32 000% was achieved using the Schottky contacted device operated in reverse bias mode at 275 °C for detection of 400 ppm CO, which is 4 orders of magnitude higher than that obtained using an Ohmic contact device under the same conditions. In addition, the response time and reset time have been shortened by a factor of 7. The methodology and principle illustrated in the paper present a new sensing mechanism that can be readily and extensively applied to other gas sensing systems. © 2009 American Chemical Society.

  8. Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis

    NARCIS (Netherlands)

    Koppes, Sjors A.; Engebretsen, Kristiane A.; Agner, Tove; Angelova-Fischer, Irena; Berents, Teresa; Brandner, Johanna; Brans, Richard; Clausen, Maja-Lisa; Hummler, Edith; Jakasa, Ivone; Jurakić-Tončic, Ružica; John, Swen M.; Khnykin, Denis; Molin, Sonja; Holm, Jan O.; Suomela, Sari; Thierse, Hermann-Josef; Kezic, Sanja; Martin, Stefan F.; Thyssen, Jacob P.

    2017-01-01

    Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant and

  9. Identification of contact and respiratory sensitizers using flow cytometry

    International Nuclear Information System (INIS)

    Goutet, Michele; Pepin, Elsa; Langonne, Isabelle; Huguet, Nelly; Ban, Masarin

    2005-01-01

    Identification of the chemicals responsible for respiratory and contact allergies in the industrial area is an important occupational safety issue. This study was conducted in mice to determine whether flow cytometry is an appropriate method to analyze and differentiate the specific immune responses to the respiratory sensitizer trimellitic anhydride (TMA) and to the contact sensitizer dinitrochlorobenzene (DNCB) used at concentrations with comparable immunogenic potential. Mice were exposed twice on the flanks (days 0, 5) to 10% TMA or 1% DNCB and challenged three times on the ears (days 10, 11, 12) with 2.5% TMA or 0.25% DNCB. Flow cytometry analyses were conducted on draining lymph node cells harvested on days 13 and 18. Comparing TMA and DNCB immune responses on day 13, we found obvious differences that persisted for most of them on day 18. An increased proportion of IgE+ cells correlated to total serum IgE level and an enhancement of MHC II molecule expression were observed in the lymph node B lymphocytes from TMA-treated mice. The percentage of IL-4-producing CD4+ lymphocytes and the IL-4 receptor expression were clearly higher following TMA exposure. In contrast, higher proportions of IL-2-producing cells were detected in CD4+ and CD8+ cells from DNCB-treated mice. Both chemicals induced a significant increase in the percentage of IFN-γ-producing cells among CD8+ lymphocytes but to a greater proportion following TMA treatment. In conclusion, this study encourages the use of flow cytometry to discriminate between contact and respiratory sensitizers by identifying divergent expression of immune response parameters

  10. Migration of human antigen-presenting cells in a human skin graft onto nude mice model after contact sensitization

    NARCIS (Netherlands)

    Hoefakker, S.; Balk, H.P.; Boersma, W.J.A.; Joost, T. van; Notten, W.R.F.; Claassen, E.

    1995-01-01

    Fluorescent contact chemical allergens provoke sensitization after application on both syngeneic and allogeneic skin grafts in mice. We attempted to determine whether the functional activity in a contact sensitization response of human skin graft was affected at the level of antigen uptake and

  11. Differential gene expression responses distinguish contact and respiratory sensitizers and nonsensitizing irritants in the local lymph node assay.

    Science.gov (United States)

    Adenuga, David; Woolhiser, Michael R; Gollapudi, B Bhaskar; Boverhof, Darrell R

    2012-04-01

    Genomic approaches have the potential to enhance the specificity and predictive accuracy of existing toxicology endpoints, including those for chemical sensitization. The present study was conducted to determine whether gene expression responses can distinguish contact sensitizers (1-chloro-2,4-dinitrobenzene [DNCB] and hexyl cinnamic aldehyde [HCA]), respiratory sensitizers (ortho-phthalaldehyde and trimellitic anhydride [TMA]), and nonsensitizing irritants (methyl salicylate [MS] and nonanoic acid [NA]) in the local lymph node assay (LLNA). Female Balb/c mice received doses of each chemical as per the standard LLNA dosing regimen on days 1, 2, and 3. Auricular lymph nodes were analyzed for tritiated thymidine ((3)HTdR) incorporation on day 6 and for gene expression responses on days 6 and 10. All chemicals induced dose-dependent increases in stimulation index, which correlated strongly with the number of differentially expressed genes. A majority of genes modulated by the irritants were similarly altered by the sensitizers, consistent with the irritating effects of the sensitizers. However, a select number of responses involved with immune-specific functions, such as dendritic cell activation, were unique to the sensitizers and may offer the ability to distinguish sensitizers from irritants. Genes for the mast cell proteases 1 and 8, Lgals7, Tim2, Aicda, Il4, and Akr1c18 were more strongly regulated by respiratory sensitizers compared with contact sensitizers and may represent potential biomarkers for discriminating between contact and respiratory sensitizers. Collectively, these data suggest that gene expression responses may serve as useful biomarkers to distinguish between respiratory and contact sensitizers and nonsensitizing irritants in the LLNA.

  12. Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis

    DEFF Research Database (Denmark)

    Koppes, Sjors A.; Engebretsen, Kristiane A.; Agner, Tove

    2017-01-01

    Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant...... and atopic dermatitis. Several studies have examined the pathogenesis and severity of allergic contact dermatitis by measuring the absence or presence of various biomarkers. In this review, we provide a non-systematic overview of biomarkers that have been studied in allergic contact dermatitis. These include...... genetic variations and mutations, inflammatory mediators, alarmins, proteases, immunoproteomics, lipids, natural moisturizing factors, tight junctions, and antimicrobial peptides. We conclude that, despite the enormous amount of data, convincing specific biomarkers for allergic contact dermatitis are yet...

  13. Evaluation of contact sensitivity to topical drugs in patients with contact dermatitis

    Directory of Open Access Journals (Sweden)

    Bilge Bülbül Şen

    2013-03-01

    Full Text Available Background and Design: Topical drugs are an important group of contact allergens. The present study aimed to evaluate contact sensitivity to topical drugs in patients with contact dermatitis. Materials and Methods: Between 2003 and 2008, 129 patients were followed up at the Department of Dermatology at Ankara University School of Medicine with clinically suspected contact sensitivity to topical drugs. In this study, the patch test reactions to the European Standard Battery and topical drugs used by the patients and medicament patch test results were evaluated. Results: Positive patch test reaction to one or more allergens was found in 80 (62.0% of 129 patients included in the study. Sixty-one of the 80 patients (61/129, 47.3% had positive patch test reaction to medicaments. Medicament sensitivity was detected in 37.9% (49/129 of subjects. Nitrofurazone was found to be the most common allergen (18.6%. Discussion: The present study showed that topical drugs are a frequent cause of allergic contact dermatitis. Therefore, the probability of contact sensitivity to topical drugs should also be considered in patients with the clinical diagnosis of allergic contact dermatitis and, suspected cases should be evaluated further with patch testing in order to find the responsible allergens.

  14. Current knowledge on biomarkers for contact sensitization and allergic contact dermatitis.

    Science.gov (United States)

    Koppes, Sjors A; Engebretsen, Kristiane A; Agner, Tove; Angelova-Fischer, Irena; Berents, Teresa; Brandner, Johanna; Brans, Richard; Clausen, Maja-Lisa; Hummler, Edith; Jakasa, Ivone; Jurakić-Tončic, Ružica; John, Swen M; Khnykin, Denis; Molin, Sonja; Holm, Jan O; Suomela, Sari; Thierse, Hermann-Josef; Kezic, Sanja; Martin, Stefan F; Thyssen, Jacob P

    2017-07-01

    Contact sensitization is common and affects up to 20% of the general population. The clinical manifestation of contact sensitization is allergic contact dermatitis. This is a clinical expression that is sometimes difficult to distinguish from other types of dermatitis, for example irritant and atopic dermatitis. Several studies have examined the pathogenesis and severity of allergic contact dermatitis by measuring the absence or presence of various biomarkers. In this review, we provide a non-systematic overview of biomarkers that have been studied in allergic contact dermatitis. These include genetic variations and mutations, inflammatory mediators, alarmins, proteases, immunoproteomics, lipids, natural moisturizing factors, tight junctions, and antimicrobial peptides. We conclude that, despite the enormous amount of data, convincing specific biomarkers for allergic contact dermatitis are yet to be described. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. An epidermal equivalent assay for identification and ranking potency of contact sensitizers

    Energy Technology Data Exchange (ETDEWEB)

    Gibbs, Susan, E-mail: S.Gibbs@VUMC.nl [Department of Dermatology, VU University Medical Centre, Dept of Oral Cell Biology, ACTA, Amsterdam (Netherlands); Corsini, Emanuela [Laboratory of Toxicology, DiSFeB, Università degli Studi di Milano (Italy); Spiekstra, Sander W. [Department of Dermatology, VU University Medical Centre, Dept of Oral Cell Biology, ACTA, Amsterdam (Netherlands); Galbiati, Valentina [Laboratory of Toxicology, DiSFeB, Università degli Studi di Milano (Italy); Fuchs, Horst W. [CellSystems GmbH, Troisdorf (Germany); DeGeorge, George; Troese, Matthew [MB Research Labs, Spinnerstown, PA (United States); Hayden, Patrick; Deng, Wei [MatTek Corporation, Ashland, MA (United States); Roggen, Erwin [3Rs Management and Consultancy (Denmark)

    2013-10-15

    The purpose of this study was to explore the possibility of combining the epidermal equivalent (EE) potency assay with the assay which assesses release of interleukin-18 (IL-18) to provide a single test for identification and classification of skin sensitizing chemicals, including chemicals of low water solubility or stability. A protocol was developed using different 3D-epidermal models including in house VUMC model, epiCS® (previously EST1000™), MatTek EpiDerm™ and SkinEthic™ RHE and also the impact of different vehicles (acetone:olive oil 4:1, 1% DMSO, ethanol, water) was investigated. Following topical exposure for 24 h to 17 contact allergens and 13 non-sensitizers a robust increase in IL-18 release was observed only after exposure to contact allergens. A putative prediction model is proposed from data obtained from two laboratories yielding 95% accuracy. Correlating the in vitro EE sensitizer potency data, which assesses the chemical concentration which results in 50% cytotoxicity (EE-EC{sub 50}) with human and animal data showed a superior correlation with human DSA{sub 05} (μg/cm{sup 2}) data (Spearman r = 0.8500; P value (two-tailed) = 0.0061) compared to LLNA data (Spearman r = 0.5968; P value (two-tailed) = 0.0542). DSA{sub 05} = induction dose per skin area that produces a positive response in 5% of the tested population Also a good correlation was observed for release of IL-18 (SI-2) into culture supernatants with human DSA{sub 05} data (Spearman r = 0.8333; P value (two-tailed) = 0.0154). This easily transferable human in vitro assay appears to be very promising, but additional testing of a larger chemical set with the different EE models is required to fully evaluate the utility of this assay and to establish a definitive prediction model. - Highlights: • A potential epidermal equivalent assay to label and classify sensitizers • Il-18 release distinguishes sensitizers from non sensitizers • IL-18 release can rank sensitizer potency

  16. An epidermal equivalent assay for identification and ranking potency of contact sensitizers

    International Nuclear Information System (INIS)

    Gibbs, Susan; Corsini, Emanuela; Spiekstra, Sander W.; Galbiati, Valentina; Fuchs, Horst W.; DeGeorge, George; Troese, Matthew; Hayden, Patrick; Deng, Wei; Roggen, Erwin

    2013-01-01

    The purpose of this study was to explore the possibility of combining the epidermal equivalent (EE) potency assay with the assay which assesses release of interleukin-18 (IL-18) to provide a single test for identification and classification of skin sensitizing chemicals, including chemicals of low water solubility or stability. A protocol was developed using different 3D-epidermal models including in house VUMC model, epiCS® (previously EST1000™), MatTek EpiDerm™ and SkinEthic™ RHE and also the impact of different vehicles (acetone:olive oil 4:1, 1% DMSO, ethanol, water) was investigated. Following topical exposure for 24 h to 17 contact allergens and 13 non-sensitizers a robust increase in IL-18 release was observed only after exposure to contact allergens. A putative prediction model is proposed from data obtained from two laboratories yielding 95% accuracy. Correlating the in vitro EE sensitizer potency data, which assesses the chemical concentration which results in 50% cytotoxicity (EE-EC 50 ) with human and animal data showed a superior correlation with human DSA 05 (μg/cm 2 ) data (Spearman r = 0.8500; P value (two-tailed) = 0.0061) compared to LLNA data (Spearman r = 0.5968; P value (two-tailed) = 0.0542). DSA 05 = induction dose per skin area that produces a positive response in 5% of the tested population Also a good correlation was observed for release of IL-18 (SI-2) into culture supernatants with human DSA 05 data (Spearman r = 0.8333; P value (two-tailed) = 0.0154). This easily transferable human in vitro assay appears to be very promising, but additional testing of a larger chemical set with the different EE models is required to fully evaluate the utility of this assay and to establish a definitive prediction model. - Highlights: • A potential epidermal equivalent assay to label and classify sensitizers • Il-18 release distinguishes sensitizers from non sensitizers • IL-18 release can rank sensitizer potency • EC50 (chemical

  17. Novel approach for classifying chemicals according to skin sensitizing potency by non-radioisotopic modification of the local lymph node assay.

    Science.gov (United States)

    Takeyoshi, Masahiro; Iida, Kenji; Shiraishi, Keiji; Hoshuyama, Satsuki

    2005-01-01

    The murine local lymph node assay (LLNA) is currently recognized as a stand-alone sensitization test for determining the sensitizing potential of chemicals, and it has the advantage of yielding a quantitative endpoint that can be used to predict the sensitization potency of chemicals. The EC3 has been proposed as a parameter for classifying chemicals according to the sensitization potency. We previously developed a non-radioisotopic endpoint for the LLNA based on 5-bromo-2'-deoxyuridine (BrdU) incorporation (non-RI LLNA), and we are proposing a new procedure to predict the sensitization potency of chemicals based on comparisons with known human contact allergens. Nine chemicals (i.e. diphencyclopropenone, p-phenylenediamine, glutaraldehyde, cinnamicaldehyde, citral, eugenol, isopropyl myristate, propyleneglycol and hexane) categorized as human contact allergen classes 1-5 were tested by the non-RI LLNA with the following reference allergens: 2,4-dinitrochlorobenzene (DNCB) as a class 1 human contact allergen, isoeugenol as a class 2 human contact allergen and alpha-hexylcinnamic aldehyde (HCA) as a class 3 human contact allergen. Consequently, nine test chemicals were almost assigned to their correct allergen class. The results suggested that the new procedure for non-RI LLNA can provide correct sensitization potency data. Sensitization potency data are useful for evaluating the sensitization risk to humans of exposure to new chemical products. Accordingly, this approach would be an effective modification of LLNA with regard to its experimental design. Moreover, this procedure can be applied also to the standard LLNA with radioisotopes and to other modifications of the LLNA. Copyright 2005 John Wiley & Sons, Ltd.

  18. Association between atopic dermatitis and contact sensitization: A systematic review and meta-analysis.

    Science.gov (United States)

    Hamann, Carsten R; Hamann, Dathan; Egeberg, Alexander; Johansen, Jeanne D; Silverberg, Jonathan; Thyssen, Jacob P

    2017-07-01

    It is unclear whether patients with atopic dermatitis (AD) have an altered prevalence or risk for contact sensitization. Increased exposure to chemicals in topical products together with impaired skin barrier function suggest a higher risk, whereas the immune profile suggests a lower risk. To perform a systematic review and meta-analysis of the association between AD and contact sensitization. The PubMed/Medline, Embase, and Cochrane databases were searched for articles that reported on contact sensitization in individuals with and without AD. The literature search yielded 10,083 citations; 417 were selected based on title and abstract screening and 74 met inclusion criteria. In a pooled analysis, no significant difference in contact sensitization between AD and controls was evident (random effects model odds ratio [OR] = 0.891; 95% confidence interval [CI] = 0.771-1.03). There was a positive correlation in studies that compared AD patients with individuals from the general population (OR 1.50, 95% CI 1.23-1.93) but an inverse association when comparing with referred populations (OR 0.753, 95% CI 0.63-0.90). Included studies used different tools to diagnose AD and did not always provide information on current or past disease. Patch test allergens varied between studies. No overall relationship between AD and contact sensitization was found. We recommend that clinicians consider patch testing AD patients when allergic contact dermatitis is suspected. Copyright © 2017 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  19. Contact sensitization and allergic contact dermatitis in patients with eczematous lesions

    Directory of Open Access Journals (Sweden)

    Perpetua U Ibekwe

    2018-01-01

    Conclusions: Most ACD patients showed contact sensitization to leather products, metal, and perfume use. This knowledge is important when considering preventive measures. However, further studies are needed to provide more insight into contact allergy in Nigeria.

  20. The role of glutathione S-transferase and claudin-1 gene polymorphisms in contact sensitization

    DEFF Research Database (Denmark)

    Ross-Hansen, K; Linneberg, A; Johansen, J D

    2013-01-01

    BACKGROUND: Contact sensitization is frequent in the general population and arises from excessive or repeated skin exposure to chemicals and metals. However, little is known about its genetic susceptibility. OBJECTIVES: To determine the role of polymorphisms of glutathione S-transferase (GST) genes...

  1. Dendritic cells' death induced by contact sensitizers is controlled by Nrf2 and depends on glutathione levels

    Energy Technology Data Exchange (ETDEWEB)

    El Ali, Zeina [UMR996 - Inflammation, Chemokines and Immunopathology-, INSERM, Univ Paris-Sud, Université Paris-Saclay, 92296 Châtenay-Malabry (France); Deloménie, Claudine [IFR141 IPSIT, Univ Paris-Sud, Université Paris-Saclay, Châtenay-Malabry (France); Botton, Jérémie [INSERM, UMR1153 Epidemiology and Biostatistics Sorbonne Paris Cité Center (CRESS), Team (France); Pallardy, Marc [UMR996 - Inflammation, Chemokines and Immunopathology-, INSERM, Univ Paris-Sud, Université Paris-Saclay, 92296 Châtenay-Malabry (France); Kerdine-Römer, Saadia, E-mail: saadia.kerdine-romer@u-psud.fr [UMR996 - Inflammation, Chemokines and Immunopathology-, INSERM, Univ Paris-Sud, Université Paris-Saclay, 92296 Châtenay-Malabry (France)

    2017-05-01

    Dendritic cells (DC) are known to play a major role during contact allergy induced by contact sensitizers (CS). Our previous studies showed that Nrf2 was induced in DC and controlled allergic skin inflammation in mice in response to chemicals. In this work, we raised the question of the role of Nrf2 in response to a stress provoked by chemical sensitizers in DC. We used two well-described chemical sensitizers, dinitrochlorobenzene (DNCB) and cinnamaldehyde (CinA), known to have different chemical reactivity and mechanism of action. First, we performed a RT-qPCR array showing that CinA was a higher inducer of immune and detoxification genes compared to DNCB. Interestingly, in the absence of Nrf2, gene expression was dramatically affected in response to DNCB but was slightly affected in response to CinA. These observations prompted us to study DC's cell death in response to both chemicals. DNCB and CinA increased apoptotic cells and decreased living cells in the absence of Nrf2. The characterization of DC apoptosis induced by both CS involved the mitochondrial-dependent caspase pathway and was regulated via Nrf2 in response to both chemicals. Oxidative stress induced by DNCB, and leading to cell death, was regulated by Nrf2. Unlike CinA, DNCB treatment provoked a significant reduction of intracellular GSH levels and up-regulated bcl-2 gene expression, under the control of Nrf2. This work underlies that chemical reactivity may control Nrf2-dependent gene expression leading to different cytoprotective mechanisms in DC. - Highlights: • Nrf2 controls cell death induced by contact sensitizers in dendritic cells. • DNCB reduced GSH levels and up-regulated bcl-2 gene expression unlike CinA. • Chemical reactivity controls Nrf2-dependent genes having protective effect in DC.

  2. International Journal of Biological and Chemical Sciences: Contact

    African Journals Online (AJOL)

    International Journal of Biological and Chemical Sciences: Contact. Journal Home > About the Journal > International Journal of Biological and Chemical Sciences: Contact. Log in or Register to get access to full text downloads.

  3. Contact allergy to preservatives in patients with occupational contact dermatitis and exposure analysis of preservatives in registered chemical products for occupational use.

    Science.gov (United States)

    Schwensen, Jakob Ferløv; Friis, Ulrik Fischer; Menné, Torkil; Flyvholm, Mari-Ann; Johansen, Jeanne Duus

    2017-05-01

    The aim of the study is to investigate risk factors for sensitization to preservatives and to examine to which extent different preservatives are registered in chemical products for occupational use in Denmark. A retrospective epidemiological observational analysis of data from a university hospital was conducted. All patients had occupational contact dermatitis and were consecutively patch tested with 11 preservatives from the European baseline series and extended patch test series during a 5-year period: 2009-2013. Information regarding the same preservatives in chemical products for occupational use ('substances and materials') registered in the Danish Product Register Database (PROBAS) was obtained. The frequency of preservative contact allergy was 14.2% (n = 141) in 995 patients with occupational contact dermatitis. Patients with preservative contact allergy had significantly more frequently facial dermatitis (19.9 versus 13.1%) and age > 40 years (71.6 versus 45.8%) than patients without preservative contact allergy, whereas atopic dermatitis was less frequently observed (12.1 versus 19.8%). Preservative contact allergy was more frequent in painters with occupational contact dermatitis as compared to non-painters with occupational contact dermatitis (p contact allergy to methylisothiazolinone and contact allergy to formaldehyde. Analysis of the registered substances and materials in PROBAS revealed that preservatives occurred in several product categories, e.g., 'paints and varnishes', 'cleaning agents', 'cooling agents', and 'polishing agents'. Formaldehyde and isothiazolinones were extensively registered in PROBAS. The extensive use of formaldehyde and isothiazolinones in chemical products for occupational use may be problematic for the worker. Appropriate legislation, substitution, and employee education should be prioritized.

  4. Multiple chemical sensitivity

    DEFF Research Database (Denmark)

    Tran, Marie Thi Dao; Arendt-Nielsen, Lars; Kupers, Ron

    2013-01-01

    BACKGROUND: Multiple Chemical Sensitivity (MCS) is a chronic condition characterized by recurrent, non-specific symptoms in response to chemically unrelated exposures in non-toxic concentrations. Although the pathophysiology of MCS remains unknown, central sensitization may be an important factor...

  5. Structure and Properties of Hydrophobic Aggregation Hydrogel with Chemical Sensitive Switch

    Directory of Open Access Journals (Sweden)

    Jiufang Duan

    2017-01-01

    Full Text Available Hydrogels with chemical sensitive switch have control release properties in special environments. A series of polyacrylamide-octadecyl methacrylate hydrogels crosslinked by N,N′-bis (acryloyl cystamine were synthesized as potential chemical sensitive system. When this hydrogel encounters dithiothreitol it can change its quality. The properties of the hydrogels were characterized by infrared spectroscopy, contact angle, and scanning electron microscopy. The water absorption of the hydrogel has the maximum value of 475%, when the content of octadecyl methacrylate is 5 wt%. The amount of weight loss was changed from 34.6% to 17.2%, as the content of octadecyl methacrylate increased from 3 wt% to 9.4 wt%. At the same time, the stress of the hydrogel decreased from 67.01% to 47.61%; the strength of the hydrogel reaches to the maximum 0.367 Mpa at 7 wt% octadecyl methacrylate. The increasing content of octadecyl methacrylate from 3 wt% to 9.4 wt% can enhance the hydrophobicity of the hydrogel; the contact angle of water to hydrogel changed from 14.10° to 19.62°. This hydrogel has the porous structure which permits loading of oils into the gel matrix. The functionalities of the hydrogel make it have more widely potential applications in chemical sensitive response materials.

  6. A plasmacytoid dendritic cell (CD123+/CD11c-) based assay system to predict contact allergenicity of chemicals

    Science.gov (United States)

    Ayehunie, Seyoum; Snell, Maureen; Child, Matthew; Klausner, Mitchell

    2009-01-01

    A predictive allergenicity test system for assessing the contact allergenicity of chemicals is needed by the cosmetic and pharmaceutical industry to monitor product safety in the marketplace. Development of such non-animal alternative assay systems for skin sensitization and hazard identification has been pursued by policy makers and regulatory agencies. We investigated whether phenotypic and functional changes to a subset of dendritic cells (DC), plasmacytoid DC (pDC), could be used to identify contact allergens. To achieve this goal, normal human DC were generated from CD34+ progenitor cells and cryopreserved. Frozen DC were thawed and the pDC fraction (CD123+/CD11c-) was harvested using FACS sorting. The pDC were cultured, expanded, and exposed to chemical allergens (N=26) or non-allergens (N=22). Concentrations of each chemical that resulted in >50% viability was determined using FACS analysis of propidium iodide stained cells using pDC from 2-5 donors. Expression of the surface marker, CD86, which has been implicated in dendritic cell maturation, was used as a marker of allergenicity. CD86 expression increased (≥ 1.5 fold) for 25 of 26 allergens (sensitivity = 96%) but did not increase for 19 of 22 non-allergens (specificity = 86%). In a direct comparison to historical data for the regulatory approved, mouse local lymph node assay (LLNA) for 23 allergens and 22 non-allergens, the pDC method had sensitivity and specificity of 96% and 86%, respectively, while the sensitivity and specificity of the LLNA assay was 83% and 82%, respectively. In conclusion, CD86 expression in pDC appears to be a sensitive and specific indicator to identify contact allergenicity. Such an assay method utilizing normal human cells will be useful for high throughput screening of chemicals for allergenicity. PMID:19665512

  7. A plasmacytoid dendritic cell (CD123+/CD11c-) based assay system to predict contact allergenicity of chemicals

    International Nuclear Information System (INIS)

    Ayehunie, Seyoum; Snell, Maureen; Child, Matthew; Klausner, Mitchell

    2009-01-01

    A predictive allergenicity test system for assessing the contact allergenicity of chemicals is needed by the cosmetic and pharmaceutical industry to monitor product safety in the marketplace. Development of such non-animal alternative assay systems for skin sensitization and hazard identification has been pursued by policy makers and regulatory agencies. We investigated whether phenotypic and functional changes to a subset of dendritic cells (DC), plasmacytoid DC (pDC), could be used to identify contact allergens. To achieve this goal, normal human DC were generated from CD34+ progenitor cells and cryopreserved. Frozen DC were thawed and the pDC fraction (CD123+/CD11c-) was harvested using FACS sorting. The pDC were cultured, expanded, and exposed to chemical allergens (N = 26) or non-allergens (N = 22). Concentrations of each chemical that resulted in >50% viability was determined using FACS analysis of propidium iodide stained cells using pDC from 2 to 5 donors. Expression of the surface marker, CD86, which has been implicated in dendritic cell maturation, was used as a marker of allergenicity. CD86 expression increased (≥1.5-fold) for 25 of 26 allergens (sensitivity = 96%) but did not increase for 19 of 22 non-allergens (specificity = 86%). In a direct comparison to historical data for the regulatory approved, mouse local lymph node assay (LLNA) for 23 allergens and 22 non-allergens, the pDC method had sensitivity and specificity of 96% and 86%, respectively, while the sensitivity and specificity of the LLNA assay was 83% and 82%, respectively. In conclusion, CD86 expression in pDC appears to be a sensitive and specific indicator to identify contact allergenicity. Such an assay method utilizing normal human cells will be useful for high throughput screening of chemicals for allergenicity.

  8. Shoe contact dermatitis from dimethyl fumarate: clinical manifestations, patch test results, chemical analysis, and source of exposure.

    Science.gov (United States)

    Giménez-Arnau, Ana; Silvestre, Juan Francisco; Mercader, Pedro; De la Cuadra, Jesus; Ballester, Isabel; Gallardo, Fernando; Pujol, Ramón M; Zimerson, Erik; Bruze, Magnus

    2009-11-01

    The methyl ester form of fumaric acid named dimethyl fumarate (DMF) is an effective mould-growth inhibitor. Its irritating and sensitizing properties were demonstrated in animal models. Recently, DMF has been identified as responsible for furniture contact dermatitis in Europe. To describe the clinical manifestations, patch test results, shoe chemical analysis, and source of exposure to DMF-induced shoe contact dermatitis. Patients with suspected shoe contact dermatitis were studied in compliance with the Declaration of Helsinki. Patch test results obtained with their own shoe and the European baseline series, acrylates and fumaric acid esters (FAE), were recorded according to international guidelines. The content of DMF in shoes was analysed with gas chromatography and mass spectrometry. Acute, immediate irritant contact dermatitis and non-immunological contact urticaria were observed in eight adults and two children, respectively. All the adult patients studied developed a delayed sensitization demonstrated by a positive patch testing to DMF Global preventive measures for avoiding contact with DMF are necessary.

  9. Airborne chemicals cause respiratory symptoms in individuals with contact allergy

    DEFF Research Database (Denmark)

    Elberling, J; Linneberg, A; Mosbech, H

    2005-01-01

    Exposure to fragrance chemicals causes various eye and airway symptoms. Individuals with perfume contact allergy report these symptoms more frequently than individuals with nickel allergy or no contact allergies. However, the associations between contact allergy and respiratory symptoms elicited...... by airborne chemicals other than perfumes are unclear. The study aimed to investigate the association between eye and airway symptoms elicited by airborne chemicals (other than perfumes) and contact allergy in a population-based sample. A questionnaire on respiratory symptoms was posted, in 2002, to 1189...... individuals who participated in 1997/1998 in a Danish population-based study of allergic diseases. Questions about eye and airway symptoms elicited by different airborne chemicals and airborne proteins were included in the questionnaire. Data from the questionnaire were compared with data on patch testing...

  10. Contact sensitivity and bioavailability of chlorocresol

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Carlsen, L; Egsgaard, Helge

    1985-01-01

    Chlorocresol sensitization from 5 topical preparations was determined in guinea pigs using the cumulative contact enhancement test. Chlorocresol 5% in olive oil/acetone (4/1), and 5% in aqueous suspension stabilized with carbomer 941 were more sensitizing (55% and 60% of the animals positive......% of the chlorocresol in aqueous suspension permeated the skin in contrast to 34% and 35% of the chlorocresol in olive oil/acetone (4/1) and propylene glycol, respectively. In spite of the same amount of chlorocresol absorption from the 2 latter preparations, they showed a significant difference in sensitizing capacity...

  11. Contact Sensitivity and Bioavailability of Chlorocresol

    DEFF Research Database (Denmark)

    Egsgaard, Helge; Larsen, Elfinn; Carlsen, Lars

    1985-01-01

    Chlorocresol sensitization from 5 topical preparations was determined in guinea pigs using the cumulative contact enhancement test. Chlorocresol 5% in olive oil/acetone (4/1), and 5% in aqueous suspension stabilized with carbomer 941 were more sensitizing (55% and 60% of the animals positive......% of the chlorocresol in aqueous suspension permeated the skin in contrast to 34% and 35% of the chlorocresol in olive oil/acetone (4/1) and propylene glycol, respectively. In spite of the same amount of chlorocresol absorption from the 2 latter preparations, they showed a significant difference in sensitizing capacity...

  12. Metals Are Important Contact Sensitizers: An Experience from Lithuania

    Directory of Open Access Journals (Sweden)

    Kotryna Linauskienė

    2017-01-01

    Full Text Available Background. Metals are very frequent sensitizers causing contact allergy and allergic contact dermatitis worldwide; up-to-date data based on patch test results has proved useful for the identification of a problem. Objectives. In this retrospective study prevalence of contact allergy to metals (nickel, chromium, palladium, gold, cobalt, and titanium in Lithuania is analysed. Patients/Methods. Clinical and patch test data of 546 patients patch tested in 2014–2016, in Vilnius University Hospital Santariskiu Klinikos, was analysed and compared with previously published data. Results. Almost third of tested patients (29.56% were sensitized to nickel. Younger women were more often sensitized to nickel than older ones (36% versus 22.8%, p=0.0011. Women were significantly more often sensitized to nickel than men (33% versus 6.1%, p<0.0001. Younger patients were more often sensitized to cobalt (11.6% versus 5.7%, p=0.0183. Sensitization to cobalt was related to sensitization to nickel (p<0.0001. Face dermatitis and oral discomfort were related to gold allergy (28% versus 6.9% dermatitis of other parts, p<0.0001. Older patients were patch test positive to gold(I sodium thiosulfate statistically significantly more often than younger ones (44.44% versus 21.21%, p=0.0281. Conclusions. Nickel, gold, cobalt, and chromium are leading metal sensitizers in Lithuania. Cobalt sensitization is often accompanied by sensitization to nickel. Sensitivity rate to palladium and nickel indicates possible cross-reactivity. No sensitization to titanium was found.

  13. Predicting allergic contact dermatitis: a hierarchical structure activity relationship (SAR) approach to chemical classification using topological and quantum chemical descriptors

    Science.gov (United States)

    Basak, Subhash C.; Mills, Denise; Hawkins, Douglas M.

    2008-06-01

    A hierarchical classification study was carried out based on a set of 70 chemicals—35 which produce allergic contact dermatitis (ACD) and 35 which do not. This approach was implemented using a regular ridge regression computer code, followed by conversion of regression output to binary data values. The hierarchical descriptor classes used in the modeling include topostructural (TS), topochemical (TC), and quantum chemical (QC), all of which are based solely on chemical structure. The concordance, sensitivity, and specificity are reported. The model based on the TC descriptors was found to be the best, while the TS model was extremely poor.

  14. Quantitative Risk Assessment of Contact Sensitization

    DEFF Research Database (Denmark)

    Api, Anne Marie; Belsito, Donald; Bickers, David

    2010-01-01

    Background: Contact hypersensitivity quantitative risk assessment (QRA) for fragrance ingredients is being used to establish new international standards for all fragrance ingredients that are potential skin sensitizers. Objective: The objective was to evaluate the retrospective clinical data...... as potential sensitizers. Methods: This article reviews clinical data for three fragrance ingredients cinnamic aldehyde, citral, and isoeugenol to assess the utility of the QRA approach for fragrance ingredients. Results: This assessment suggests that had the QRA approach been available at the time standards...

  15. Contact and respiratory sensitizers can be identified by cytokine profiles following inhalation exposure

    International Nuclear Information System (INIS)

    De Jong, Wim H.; Arts, Josje H.E.; De Klerk, Arja; Schijf, Marcel A.; Ezendam, Janine; Kuper, C. Frieke; Van Loveren, Henk

    2009-01-01

    There are currently no validated animal models that can identify low molecular weight (LMW) respiratory sensitizers. The Local Lymph Node Assay (LLNA) is a validated animal model developed to detect contact sensitizers using skin exposure, but all LMW respiratory sensitizers tested so far were also positive in this assay. Discrimination between contact and respiratory sensitizers can be achieved by the assessment of cytokine profiles. In a LLNA using the inhalation route, both contact and respiratory sensitizers enhanced proliferation in the draining lymph nodes. The question was if their cytokine profiles were affected by the route of exposure. Male BALB/c mice were exposed head/nose-only during 3 consecutive days to the respiratory sensitizers trimellitic anhydride, phthalic anhydride, toluene diisocyanate, hexamethylene diisocyanate (HDI), and isophorone diisocyanate; the contact sensitizers dinitrochlorobenzene (DNCB), oxazolone (OXA) and formaldehyde (FA), and the irritant methyl salicylate (MS). Three days after the last exposure the draining lymph nodes were excised and cytokine production was measured after ex vivo stimulation with Concanavalin A. Skin application was used as a positive control. After inhalation exposure the respiratory sensitizers induced more interleukin-4 (IL-4) and interleukin (IL-10) compared to the contact sensitizers, whereas the contact sensitizers, except formaldehyde, induced relatively more interferon-γ (IFN-γ) production. When IL-4 and IFN-γ were plotted as a function of the proliferative response, it was shown that IL-4 could be used to identify respiratory sensitizers, except HDI, at concentration levels inducing intermediate stimulation indices. HDI could be distinguished from DNCB and OXA at high SI values. In contrast, contact sensitizers could only be identified when IFN-γ was measured at high stimulation indices. The skin positive control, tested at high concentrations, showed comparable results for IL-4 and IL-10

  16. INFLUENCE OF MODIFIED BIOFLAVONOIDS UPON EFFECTOR LYMPHOCYTES IN MURINE MODEL OF CONTACT SENSITIVITY

    Directory of Open Access Journals (Sweden)

    D. Z. Albegova

    2015-01-01

    Full Text Available Contact sensitivity reaction (CSR to 2,4-dinitrofluorobenzene (DNFB in mice is a model of in vivo immune response, being an experimental analogue to contact dermatitis in humans. CSR sensitization phase begins after primary contact with antigen, lasting for 10-15 days in humans, and 5-7 days, in mice. Repeated skin exposure to the sensitizing substance leads to its recognition and triggering immune inflammatory mechanisms involving DNFB-specific effector T lymphocytes. The CSR reaches its maximum 18-48 hours after re-exposure to a hapten. There is only scarce information in the literature about effects of flavonoids on CSR, including both stimulatory and inhibitory effects. Flavonoids possessed, predominantly, suppressive effects against the CSR development. In our laboratory, a model of contact sensitivity was reproduced in CBA mice by means of cutaneous sensitization by 2,4-dinitrofluorobenzene. The aim of the study was to identify the mechanisms of immunomodulatory action of quercetin dihydrate and modified bioflavonoids, using the method of adoptive transfer contact sensitivity by splenocytes and T-lymphocytes. As shown in our studies, a 30-min pre-treatment of splenocytes and T-lymphocytes from sensitized mice with modified bioflavonoids before the cell transfer caused complete prevention of contact sensitivity reaction in syngeneic recipient mice. Meanwhile, this effect was not associated with cell death induction due to apoptosis or cytotoxicity. Quercetin dihydrate caused only partially suppression the activity of adaptively formed T-lymphocytes, the contact sensitivity effectors. It was shown that the modified bioflavonoid more stronger suppress adoptive transfer of contact sensitivity in comparison with quercetin dehydrate, without inducing apoptosis of effector cells. Thus, the modified bioflavonoid is a promising compound for further studies in a model of contact sensitivity, due to its higher ability to suppress transfer of CSR with

  17. CMS Sensitivity to Quark Contact Interactions using Dijets

    CERN Document Server

    Esen, Selda

    2006-01-01

    We estimate CMS sensitivity to quark contact interactions in the dijet final state. The canonical model of a contact interaction among left-handed composite quarks changes the dijet angular distribution at high dijet mass. The dijet ratio variable introduced at the Tevatron is used as a simple measure of the angular distribution as a function of dijet mass. The contact interaction signal and QCD background are estimated for the dijet ratio as a function of dijet mass from 0.3 to 6.5 TeV. Statistical uncertainties are estimated for integrated luminosities of 100 pb^-1, 1 fb^-1, and 10 fb^-1 and a realistic trigger table including multiple thresholds and prescales for the single jet triggers. Systematic uncertainties on the dijet ratio are estimated and are found to be small. The chisquard between the background and the signal is estimated, including systematics, and is used to find CMS sensitivity to the contact interaction scale Lambda^+. For an integrated luminosity of 100 pb^-1, 1 fb^-1, and 10 fb^-1, CMS c...

  18. Contact allergy to preservatives in patients with occupational contact dermatitis and exposure analysis of preservatives in registered chemical products for occupational use

    DEFF Research Database (Denmark)

    Schwensen, Jakob Ferløv; Friis, Ulrik Fischer; Menné, Torkil

    2017-01-01

    PURPOSE: The aim of the study is to investigate risk factors for sensitization to preservatives and to examine to which extent different preservatives are registered in chemical products for occupational use in Denmark. METHODS: A retrospective epidemiological observational analysis of data from...... a university hospital was conducted. All patients had occupational contact dermatitis and were consecutively patch tested with 11 preservatives from the European baseline series and extended patch test series during a 5-year period: 2009-2013. Information regarding the same preservatives in chemical products...... in several product categories, e.g., 'paints and varnishes', 'cleaning agents', 'cooling agents', and 'polishing agents'. Formaldehyde and isothiazolinones were extensively registered in PROBAS. CONCLUSIONS: The extensive use of formaldehyde and isothiazolinones in chemical products for occupational use may...

  19. [Epidemiology of contact dermatitis: prevalence of sensitization to different allergens and associated factors].

    Science.gov (United States)

    Bordel-Gómez, Ma T; Miranda-Romero, A; Castrodeza-Sanz, J

    2010-01-01

    In clinical practice, contact dermatitis is a relatively common skin complaint, whose prevalence has increased in recent years. Study by patch testing is essential for diagnosis of contact sensitization. To study the prevalence of sensitization to different allergens in a standard battery and observe the influence of different epidemiological and clinical variables on contact sensitization. A large number of allergens were included in our battery in order to detect new sensitizations whose prevalence might justify further study. This was a retrospective, observational, epidemiological study of 1092 patients, conducted in our skin allergy unit between January 1, 2000, and December 31, 2005. All patients were studied with a battery of 51 allergens. We assessed the following variables: sex, age, type of referral, occupation, site and course of skin lesions, personal and family history of atopy, positive patch tests, clinical significance, diagnosis, source of sensitization, and occupational relationship. At least 1 positive result was found in 55% of the patients, and 55.7% presented atopic dermatitis in one of its clinical variants: allergic contact dermatitis (28.2%), irritant contact dermatitis (20.1%), photoallergic contact dermatitis (2.2%), and phototoxic contact dermatitis (1.2%). The most prevalent allergens were nickel sulfate (29.3%), palladium chloride (11.7%), cobalt chloride (10.8%), potassium dichromate (7.5%), fragrance blends (6.3%), and p-phenylenediamine (6.1%). A positive occupational relationship was found in 41.1%, and 21.3% of the patients studied were diagnosed with occupational contact dermatitis. Metal workers, construction workers, and professional hairdressers were the most strongly represented groups. The most common source of sensitization was contact with metallic objects, followed by drugs, cosmetics, and rubber items. Female sex was the only independent variable that had a significant influence on the risk of contact sensitization in

  20. Immune suppression with supraoptimal doses of antigen in contact sensitivity. I. Demonstration of suppressor cells and their sensitivity to cyclophosphamide.

    Science.gov (United States)

    Sy, M S; Miller, S D; Claman, H N

    1977-07-01

    Immunologic suppression was induced in a mouse model of contact sensitization to DNFB by using supraoptimal doses of antigen. In these studies, in vivo measurement of ear swelling as an indication of immunologic responsiveness correlated well with measurement of in vitro antigen-induced cell proliferation. This unresponsiveness was specific, since supraoptimal doses of DNFB did not interfere with the development of contact sensitivity to another contactant, oxazolone. The decrease in responsiveness is a form of active suppression, as lymphoid cells from supraoptimally sensitized donors transferred suppression to normal recipients. Furthermore, pretreatment with cyclophosphamide (Cy) reversed the suppression seen in supraoptimally sensitized animals but had no effect on the optimal sensitization regimen. These results indicate that supraoptimal doses of contactants can activate suppressor cells and that precursors of these cells are sensitive to Cy. Such suppressors regenerate within 7 to 14 days after Cy treatment. The ability of Cy pretreatment to affect supraoptimal sensitization without affecting optimal sensitization confirms other reports indicating that the observed results of Cy treatment depend critically upon the dose of antigen used.

  1. Contact sensitivity in palmar hyperkeratotic dermatitis

    Directory of Open Access Journals (Sweden)

    Minocha Y

    1993-01-01

    Full Text Available 230 patients presenting with palmar hyperkeratotic dermatitis were investigated by patch tests against various antigens depending upon occupation of the patients. Contact sensitivity was detected in 130 patients comprising of housewives (55, businessmen (20, farmers (15, teachers / clerks / students (13, doctors and nurses (9, factory workers and labourers (8, massons (7 and motor mechanics (3. Vegetables were found to be the most common agents followed by detergents and metals predominantly affecting housewives. Among the vegetables, garlic and onion were the most potent sensitizers whereas nickel was a common sensitizer among metals. Occupational factors were seen to have some influence in relation to the causative agents as indicated by higher positivity of vegetables in housewives; detergents, metals, rubber, leather, plastics in businessmen, teachers, clerks and students; fertilizers or animal foods in farmers; drugs in doctors and nurses and chromium and cobalt in massons.

  2. Hair dye dermatitis and p-phenylenediamine contact sensitivity: A preliminary report

    Directory of Open Access Journals (Sweden)

    Mrinal Gupta

    2015-01-01

    Full Text Available Background: The contact allergic reactions from p-phenylenediamine (PPD in hair dyes vary from mild contact dermatitis to severe life- threatening events (angioedema, bronchospasm, asthma, renal impairment. Objectives: To study the clinical patterns and PPD contact sensitivity in patients with hair-dye dermatitis. Materials and Methods: Eighty (M: F 47:33 consecutive patients aged between 18 and 74 years suspected to have contact allergy from hair dye were studied by patch testing with Indian Standard Series including p-phenylenediamine (PPD, 1.0% pet. Results: 54 Fifty-four (M: F 21:33 patients showed positive patch tests from PPD. Eight of these patients also showed positive patch test reaction from fragrance mix, thiuram mix, paraben mix, or colophony. Fifty-seven (71% patients affected were aged older than 40 years. The duration of dermatitis varied from 1 year with exacerbation following hair coloring. Forty-nine patients had dermatitis of scalp and/or scalp margins and 23 patients had face and neck dermatitis. Periorbital dermatitis, chronic actinic dermatitis, and erythema multiforme-like lesions were seen in 4, 2, and 1 patients, respectively. Conclusions: Hair dyes and PPD constitute a significant cause of contact dermatitis. There is an urgent need for creating consumer awareness regarding hair-dyes contact sensitivity and the significance of performing sensitivity testing prior to actual use.

  3. Effect of tobacco smoking and alcohol consumption on the prevalence of nickel sensitization and contact sensitization

    DEFF Research Database (Denmark)

    Thyssen, Jacob P; Johansen, Jeanne D; Menné, Torkil

    2010-01-01

    There is evidence that stimulants such as alcohol and tobacco have an effect on the immune system, but little is known about how these lifestyle factors affect the prevalence of contact sensitization. This study investigated whether smoking and alcohol consumption were associated with contact...

  4. Identification of Lilial as a fragrance sensitizer in a perfume by bioassay-guided chemical fractionation and structure-activity relationships.

    Science.gov (United States)

    Arnau, E G; Andersen, K E; Bruze, M; Frosch, P J; Johansen, J D; Menné, T; Rastogi, S C; White, I R; Lepoittevin, J P

    2000-12-01

    Fragrance materials are among the most common causes of allergic contact dermatitis. The aim of this study was to identify in a perfume fragrance allergens not included in the fragrance mix, by use of bioassay-guided chemical fractionation and chemical analysis/structure-activity relationships (SARs). The basis for the investigation was a 45-year-old woman allergic to her own perfume. She had a negative patch test to the fragrance mix and agreed to participate in the study. Chemical fractionation of the perfume concentrate was used for repeated patch testing and/or repeated open application test on the pre-sensitized patient. The chemical composition of the fractions giving a positive patch-test response and repeated open application test reactions was obtained by gas chromatography-mass spectrometry. From the compounds identified, those that contained a "structural alert" in their chemical structure, indicating an ability to modify skin proteins and thus behave as a skin sensitizer, were tested on the patient. The patient reacted positively to the synthetic fragrance p-t-butyl-alpha-methylhydrocinnamic aldehyde (Lilial), a widely used fragrance compound not present in the fragrance mix. The combination of bioassay-guided chemical fractionation and chemical analysis/structure-activity relationships seems to be a valuable tool for the investigation of contact allergy to fragrance materials.

  5. Analysis of Wetting and Contact Angle Hysteresis on Chemically Patterned Surfaces

    KAUST Repository

    Xu, Xianmin; Wang, Xiaoping

    2011-01-01

    Wetting and contact angle hysteresis on chemically patterned surfaces in two dimensionsare analyzed from a stationary phase-field model for immiscible two phase fluids. We first study the sharp-interface limit of the model by the method of matched asymptotic expansions. We then justify the results rigorously by the γ-convergence theory for the related variational problem and study the properties of the limiting minimizers. The results also provide a clear geometric picture of the equilibrium configuration of the interface. This enables us to explicitly calculate the total surface energy for the two phase systems on chemically patterned surfaces with simple geometries, namely the two phase flow in a channel and the drop spreading. By considering the quasi-staticmotion of the interface described by the change of volume (or volume fraction), we can follow the change-of-energy landscape which also reveals the mechanism for the stick-slip motion of the interface and contact angle hysteresis on the chemically patterned surfaces. As the interface passes throughpatterned surfaces, we observe not only stick-slip of the interface and switching of the contact angles but also the hysteresis of contact point and contact angle. Furthermore, as the size of the patternde creases to zero, the stick-slip becomes weaker but the hysteresis becomes stronger in the sense that one observes either the advancing contact angle or the receding contact angle (when the interface ismoving in the opposite direction) without the switching in between. © 2011 Society for Industrial and Applied Mathematics.

  6. CONTACT DERMATITIS TO METHYLDIBROMOGLUTARONITRILE: EMERGENCE OF SENSITIZATION IN THE CENTRAL REGION OF TUNISIA

    Directory of Open Access Journals (Sweden)

    Maher Maoua

    2018-06-01

    Full Text Available Methyldibromoglutaronitrile (MDBGN is a preservative found in cosmetics as well as in products for industrial use. It caused an outbreak of allergic contact dermatitis in Europe in the 1990s and early 2000s. To assess the prevalence of MDBGN sensitization among consultants in the occupational dermato-allergology unit of Farhat Hached University Hospital in Sousse-Tunisia, we carried out a study of all cases of contact dermatitis to MDBGN confirmed by patch-tests from 1 January 2011 to 31 December 2015. The prevalence of allergic contact dermatitis to MDBGN was 4.5% of all cases of contact dermatitis recorded during the same period with an increase from 1.7% in 2011 to 5.4% in 2015. Associated allergens with contact dermatitis to MDBGN were the Peru balsam in 4 cases, nickel sulfate and kathon CG in 3 cases each. Contact dermatitis to Dibromodicyanobutane was associated with sensitization to other preservatives in 4 cases and cosmetic allergens in 6 cases. An increasing rates of sensitization are noticed in our region. The absence of legal restrictions regarding this preservative agent may explain an increase of its use in non-European countries.

  7. Multiple Chemical Sensitivity

    DEFF Research Database (Denmark)

    Junge, Anne Gram

    Et voksende antal mennesker i Danmark oplever at være overfølsomme over for dufte og kemikalier. Imidlertid er den tilskrevne diagnose Multiple Chemical Sensitivity (MCS) ikke medicinsk anerkendt i Danmark pga. mangel på organiske og patofysiologisk basis for symptomerne. Dette speciale bygger på...

  8. Expression of surface markers on the human monocytic leukaemia cell line, THP-1, as indicators for the sensitizing potential of chemicals.

    Science.gov (United States)

    An, Susun; Kim, Seoyoung; Huh, Yong; Lee, Tae Ryong; Kim, Han-Kon; Park, Kui-Lea; Eun, Hee Chul

    2009-04-01

    Evaluation of skin sensitization potential is an important part of the safety assessment of cosmetic ingredients and topical drugs. Recently, evaluation of changes in surface marker expression induced in dendritic cells (DC) or DC surrogate cell lines following exposure to chemicals represents one approach for in vitro test methods. The study aimed to test the change of expression patterns of surface markers on THP-1 cells by chemicals as a predictive in vitro method for contact sensitization. We investigated the expression of CD54, CD86, CD83, CD80, and CD40 after a 1-day exposure to sensitizers (1-chloro-2,4-dinitrobenzene; 2,4-dinitrofluorobenzene; benzocaine; 5-chloro-2-methyl-4-isothiazolin-3-one; hexyl cinnamic aldehyde; eugenol; nickel sulfate hexahydrate; potassium dichromate; cobalt sulfate; 2-mercaptobenzothiazole; and ammonium tetrachloroplatinate) and non-sensitizers (sodium lauryl sulfate, benzalkonium chloride, lactic acid, salicylic acid, isopropanol, and dimethyl sulphoxide). The test concentrations were 0.1x, 0.5x, and 1x of the 50% inhibitory concentration, and the relative fluorescence intensity was used as an expression indicator. By evaluating the expression patterns of CD54, CD86, and CD40, we could classify the chemicals as sensitizers or non-sensitizers, but CD80 and CD83 showed non-specific patterns of expression. These data suggest that the THP-1 cells are good model for screening contact sensitizers and CD40 could be a useful marker complementary to CD54 and CD86.

  9. Prevalence and effects of multiple chemical sensitivities in Australia

    Directory of Open Access Journals (Sweden)

    Anne Steinemann

    2018-06-01

    Full Text Available Multiple chemical sensitivities (MCS is a medical condition associated with exposure to common chemical pollutants. The aims of this study are to assess the prevalence of MCS, its overlaps with asthma and fragrance sensitivity, and its health and societal effects in Australia. Data were collected in June 2016 using an on-line survey with a representative national sample (N = 1098 of adults (ages 18–65 in Australia. Results found that, across the country, 6.5% report medically diagnosed MCS, 18.9% report chemical sensitivity (being unusually sensitive to everyday chemicals and chemically formulated products, and 19.9% either or both. Among people with MCS, 74.6% also have diagnosed asthma or an asthma-like condition, and 91.5% have fragrance sensitivity, reporting health problems (such as migraine headaches when exposed to fragranced consumer products (such as air fresheners and cleaning supplies. In addition, among people with MCS, 77.5% are prevented from access to places because of fragranced products, 52.1% lost workdays or a job in the past year due to fragranced product exposure in the workplace, and 55.4% report health effects considered potentially disabling. Results indicate that MCS is a widespread disease, affecting an estimated 1 million adult Australians, with chemical sensitivity affecting another 2 million. Reducing chemical exposure to problematic sources, such as fragranced consumer products, is critical to reduce adverse effects. Keywords: MCS, Multiple chemical sensitivities, Chemical sensitivity, Asthma, Fragrance sensitivity, Fragranced consumer products

  10. Multiple Chemical Sensitivity

    DEFF Research Database (Denmark)

    Dantoft, Thomas Meinertz

    Multiple chemical sensitivity (MCS) is a chronic disorder characterized by reports of symptoms from various organ systems attributed by the individuals to exposure to common odors and airborne chemicals in doses far below those known to induce toxic effects. There exists a general lack of knowledge......, significantly reduced levels of IL-13 in the MCS group and no group differences in the allergen specific IgE measures. The differences were independent of factors such as sex, age, Body Mass Index, asthma, smoking, depression, anxiety and allergen-specific IgE. In conclusion, the study identified a distinct...

  11. Chemical identification of contaminants in paper and board food contact materials

    DEFF Research Database (Denmark)

    Bengtström, Linda

    Paper and board are used for a variety of food contact materials, such as baking paper, microwave popcorn bags and packaging for cereals as well as fast foods. Despite this extensive use, there are currently large data gaps about the chemical composition of different paper and board food contact...

  12. Tribo-chemical behavior of eutectoid steel during rolling contact friction

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y.; Cai, Z.B. [Key Laboratory of Advanced Technologies of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu 610031 (China); Peng, J.F. [Tribology Research Institute, State Key Laboratory of Traction Power, Southwest Jiaotong University, Chengdu 610031 (China); Cao, B.B. [Key Laboratory of Advanced Technologies of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu 610031 (China); Jin, X.S. [Tribology Research Institute, State Key Laboratory of Traction Power, Southwest Jiaotong University, Chengdu 610031 (China); Zhu, M.H., E-mail: zhuminhao@swjtu.cn [Key Laboratory of Advanced Technologies of Materials, Ministry of Education, Southwest Jiaotong University, Chengdu 610031 (China); Tribology Research Institute, State Key Laboratory of Traction Power, Southwest Jiaotong University, Chengdu 610031 (China)

    2016-12-01

    Highlights: • Tribo-chemical behavior was investigated during rolling contact friction. • Tribo-film may weaken the absorptive ability of O/C atoms on the surface. • Tribo-film is related to a low friction coefficient at rolling friction condition. - Abstract: The tribo-chemical behavior of the eutectoid steel during rolling contact friction is investigated via scanning electron microscopy, X-ray diffraction, X-ray photoelectron spectroscopy (XPS) and electron probe X-ray microanalysis. The worn surface is divided into three zones: matrix zone (without friction), tribo-film zone (formed during friction) and delamination zone (tribo-film spalling). The different chemical states of atoms between those three zones and the air were investigated using the XPS analysis. The results showed that the matrix zone is composed of Fe{sub 2}O{sub 3}, FeO and metallic Fe, while the tribo-film and delamination zones only contain Fe{sub 2}O{sub 3} and FeO. Where the tribo-film is formed, the absorptive ability of O and C atoms on the top 2–3 atomic layers is probably weakened, while the exposed fresh metal in the delamination zone tends to be continuously oxidized and form tribo-film. The tribo-chemical reaction in the delamination zone is more activated than that in the other two zones. The protective nature of the tribo-film probably maintains a low friction coefficient under rolling contact friction condition.

  13. Predicting a contact's sensitivity to initial conditions using metrics of frictional coupling

    International Nuclear Information System (INIS)

    Flicek, Robert C.; Hills, David A.; Brake, Matthew Robert W.

    2016-01-01

    This paper presents a method for predicting how sensitive a frictional contact’s steady-state behavior is to its initial conditions. Previous research has proven that if a contact is uncoupled, i.e. if slip displacements do not influence the contact pressure distribution, then its steady-state response is independent of initial conditions, but if the contact is coupled, the steady-state response depends on initial conditions. In this paper, two metrics for quantifying coupling in discrete frictional systems are examined. These metrics suggest that coupling is dominated by material dissimilarity due to Dundurs’ composite material parameter β when β ≥ 0.2, but geometric mismatch becomes the dominant source of coupling for smaller values of β. Based on a large set of numerical simulations with different contact geometries, material combinations, and friction coefficients, a contact’s sensitivity to initial conditions is found to be correlated with the product of the coupling metric and the friction coefficient. For cyclic shear loading, this correlation is maintained for simulations with different contact geometries, material combinations, and friction coefficients. Furthermore, for cyclic bulk loading, the correlation is only maintained when the contact edge angle is held constant.

  14. Chemically sensitive interfaces on SAW devices

    Energy Technology Data Exchange (ETDEWEB)

    Ricco, A.J.; Martin, S.J. [Sandia National Labs., Albuquerque, NM (United States); Crooks, R.M.; Xu, Chuanjing [Texas A and M Univ., College Station, TX (United States); Allred, R.E. [Adherent Technologies, Inc., Albuquerque, NM (United States)

    1993-11-01

    Using surface acoustic wave (SAW) devices, three approaches to the effective use of chemically sensitive interfaces that are not highly chemically selective have been examined: (1) molecular identification from time-resolved permeation transients; (2) using multifrequency SAW devices to determine the frequency dependence of analyte/film interactions; (3) use of an array of SAW devices bearing diverse chemically sensitive interfaces to produce a distinct response pattern for each analyte. In addition to their well-known sensitivity to mass changes (0.0035 monolayer of N{sub 2} can be measured), SAW devices respond to the mechanical and electronic properties of thin films, enhancing response information content but making a thorough understanding of the perturbation critical. Simultaneous measurement of changes in frequency and attenuation, which can provide the information necessary to determine the type of perturbation, are used as part of the above discrimination schemes.

  15. Genetic susceptibility factors for multiple chemical sensitivity revisited

    DEFF Research Database (Denmark)

    Berg, Nikolaj Drimer; Rasmussen, Henrik Berg; Linneberg, Allan

    2010-01-01

    of this study was to investigate genetic susceptibility factors for MCS and self-reported chemical sensitivity in a population sample. Ninety six MCS patients and 1,207 controls from a general population divided into four severity groups of chemical sensitivity were genotyped for variants in the genes encoding......Multiple chemical sensitivity (MCS) is characterised by adverse effects due to exposure to low levels of chemical substances. Various genes, especially genes of importance to the metabolism of xenobiotic compounds, have been associated with MCS, but findings are inconsistent. The purpose...... significant (OR=1.2, p=0.28). Fast arylamine N-acetyltransferase 2 metaboliser status was associated with severity of chemical sensitivity only in the most severely affected group in the population sample (OR=3.1, p=0.04). The cholecystokinin 2 receptor allele with 21 CT repeats was associated with MCS when...

  16. Development and Utilization of an Ex Vivo Bromodeoxyuridine Local Lymph Node Assay (LLNA) Protocol for Assessing Potential Chemical Sensitizers

    Science.gov (United States)

    The murine local lymph node assay (LLNA) is widely used to identify chemicals that may cause allergic contact dermatitis. Exposure to a dermal sensitizer results in proliferation of local lymph node T cells, which has traditionally been measured by in vivo incorporation of [3H]m...

  17. The safety and efficacy of contact lens wear in the industrial and chemical workplace.

    Science.gov (United States)

    Tyhurst, Keith; McNett, Ryan; Bennett, Edward

    2007-11-01

    The use and safety of contact lenses in the industrial and chemical workplace has often been questioned since the 1960s because of many unconfirmed reports of ocular injury resulting from contact lens wear. Because of these urban legends, contact lens wear has been banned or wearers have been required to wear additional personal protective equipment (PPE) not required of non-contact lens wearers. Literature review via Medline and Google search. Research has shown that contact lenses typically provide protective benefits that decrease the severity of ocular injury and improve worker performance. While contact lens wear contraindications do exist, in most cases, and with proper precautions, contact lens wear is still possible. Industrial and chemical companies need to establish written contact lens use policies based on current studies that have shown the safety of workplace contact lens wear when combined with the same PPE required of non-contact lens wearers. Practitioners need to discuss, with their contact lens patients, the additional responsibilities required to maintain proper lens hygiene and proper PPE in the workplace.

  18. Human sensitivity to eye contact in 2D and 3D videoconferencing

    NARCIS (Netherlands)

    Eijk, van R.L.J.; Kuijsters, A.; Dijkstra, K.I.; IJsselsteijn, W.A.

    2010-01-01

    Gaze awareness and eye contact serve important functions in social interaction. In order to maintain those functions in 2D and 3D videoconferencing systems, human sensitivity to eye contact and gaze direction needs to be taken into account in the design of such systems. Here we experimentally

  19. Defect-engineered graphene chemical sensors with ultrahigh sensitivity.

    Science.gov (United States)

    Lee, Geonyeop; Yang, Gwangseok; Cho, Ara; Han, Jeong Woo; Kim, Jihyun

    2016-05-25

    We report defect-engineered graphene chemical sensors with ultrahigh sensitivity (e.g., 33% improvement in NO2 sensing and 614% improvement in NH3 sensing). A conventional reactive ion etching system was used to introduce the defects in a controlled manner. The sensitivity of graphene-based chemical sensors increased with increasing defect density until the vacancy-dominant region was reached. In addition, the mechanism of gas sensing was systematically investigated via experiments and density functional theory calculations, which indicated that the vacancy defect is a major contributing factor to the enhanced sensitivity. This study revealed that defect engineering in graphene has significant potential for fabricating ultra-sensitive graphene chemical sensors.

  20. Risk assessment of contact allergens: a feasibility study

    NARCIS (Netherlands)

    Iersel AAJ van; LEO; LGM; LPI

    1996-01-01

    Skin sensitization, allergic contact dermatitis, is not a life-threatening condition but it can be very impairing. For that reason contemporary legislation prescribes the assessment of the skin sensitizing properties of substances like chemicals, house-hold and personel-care products. In general,

  1. Contact and respiratory sensitizers can be identified by cytokine profiles following inhalation exposure

    NARCIS (Netherlands)

    Jong, W.H. de; Arts, J.H.E.; Klerk, A. de; Schijf, M.A.; Ezendam, J.; Kuper, C.F.; Loveren, H. van

    2009-01-01

    There are currently no validated animal models that can identify low molecular weight (LMW) respiratory sensitizers. The Local Lymph Node Assay (LLNA) is a validated animal model developed to detect contact sensitizers using skin exposure, but all LMW respiratory sensitizers tested so far were also

  2. Sensory irritation and multiple chemical sensitivity.

    Science.gov (United States)

    Anderson, R C; Anderson, J H

    1999-01-01

    Many of the symptoms described in Sick Building Syndrome (SBS) and multiple chemical sensitivity (MCS) resemble the symptoms known to be elicited by airborne irritant chemicals. Irritation of the eye, nose, and throat is common to SBS, MCS, and sensory irritation (SI). Difficulty of breathing is often seen with SBS, MCS, and pulmonary irritation (PI). We therefore asked the question: can indoor air pollutants cause SI and/or PI? In laboratory testing in which mice breathed the dilute volatile emissions of air fresheners, fabric softeners, colognes, and mattresses for 1 h, we measured various combinations of SI and PI as well as airflow decreases (analogous to asthma attacks). Air samples taken from sites associated with repeated human complaints of poor air quality also caused SI, PI, and airflow limitation (AFL) in the mice. In previous publications, we have documented numerous behavior changes in mice (which we formally studied with a functional observational battery) after exposure to product emissions or complaint site air; neurological complaints are a prominent part of SBS and MCS. All together, these data suggest that many symptoms of SBS and MCS can be described as SI, PI, AFL, and neurotoxicity. All these problems can be caused by airborne irritant chemicals such as those emitted by common commercial products and found in polluted indoor air. With some chemical mixtures (e.g., emissions of some fabric softeners, disposable diapers, and vinyl mattress covers) but not others (e.g., emissions of a solid air freshener), the SI response became larger (2- to 4-fold) when we administered a series of two or three 1-h exposures over a 24-h period. Since with each exposure the intensity of the stimulus was constant yet the magnitude of the response increased, we concluded that there was a change in the sensitivity of the mice to these chemicals. The response was not a generalized stress response because it occurred with only some mixtures of irritants and not others

  3. Encapsulating contact allergens in liposomes, ethosomes, and polycaprolactone may affect their sensitizing properties

    DEFF Research Database (Denmark)

    Madsen, Jakob Torp; Vogel, Stefan; Johansen, Jeanne Duus

    2011-01-01

    Attempts to improve formulation of topical products are a continuing process and the development of micro- and nanovesicular systems as well as polymeric microparticles has led to marketing of topical drugs and cosmetics using these technologies. Encapsulation of some well-known contact allergens...... in ethanolic liposomes have been reported to enhance allergenicity compared with the allergens in similar vehicles without liposomes. The present report includes data on more sensitization studies using the mouse local lymph node assay with three contact allergens encapsulated in different dermal drug...... dichromate compared with control solutions. However, encapsulating the lipophilic contact allergen dinitrochlorobenzene (DNCB) in polycaprolactone reduced the sensitizing capacity to 1211 ± 449 compared with liposomes (7602 ± 2658) and in acetone:olive oil (4:1) (5633 ± 666). The same trend was observed...

  4. CONCURRENT CONTACT SENSITIZATION TO METALS IN DENTAL EXPOSURES

    Directory of Open Access Journals (Sweden)

    Maya Lyapina

    2018-03-01

    Full Text Available Purpose: Sensitization to metals is a significant problem for both dental patients treated with dental materials and for dental professionals in occupational exposures. The purpose of the present study was to evaluate the incidence of concurrent contact sensitization to relevant for dental practice metals among students of dental medicine, students from dental technician school, dental professionals and patients. Material and Methods: A total of 128 participants were included in the study. All of them were patch-tested with nickel, cobalt, copper, potassium dichromate, palladium, aluminium, gold and tin. The results were subject to statistical analysis (p < 0.05. Results: For the whole studied population, potassium dichromate exhibited concomitant reactivity most often; copper and tin also often manifested co-reactivity. For the groups, exposed in dental practice, potassium dichromate and tin were outlined as the most often co-reacting metal allergens, but statistical significance concerning the co-sensitization to copper and the other metals was established only for aluminium. An increased incidence and OR for concomitant sensitization to cobalt and nickel was established in the group of dental students; to copper and nickel - in the control group; to palladium and nickel - in the group of dental professionals, the group of students of dental medicine and in the control group; to potassium dichromate and cobalt - in the group of dental students; to copper and palladium - in the control group of dental patients; to potassium dichromate and copper - in the group of dental professionals; to copper and aluminum - in the groups of students from dental technician school and of dental professionals; to copper and gold - in the groups of dental professionals and in the group of dental patients; to potassium dichromate and aluminum - in the group of dental professionals; to potassium dichromate and gold - in the group of dental professionals, and to

  5. The Prevalence of Allergic Contact Sensitization of Practicing and Student Nurses

    Directory of Open Access Journals (Sweden)

    A Akan

    2011-12-01

    Full Text Available Background: Contact dermatitis (CD is a significant problem among nurses. Although there are reports about the prevalence of CD from different parts of the world, data about its frequency in Turkey and about allergic contact sensitization among nurses is insufficient. Objective: To define the frequency and patterns of allergic contact sensitization and related symptoms in practicing and student nurses. Methods: There were 123 nurses in our hospital practicing in the in-patient clinics. All were invited to participate in the study. 69 working-in nurses and 79 student nurses participated in the study. The main reason for refusal of nurses was that they were usually having a shower daily after a hard working day and they had to postpone having a bath for 3 days if they had a patch test on their back. A ready-to-use patch test system (TRUE test® with 29 standardized test substances was applied to all of the participants. History about symptoms of CD and allergic diseases was investigated by questionnaire. Results: While 34.8% (24/69 of practicing nurses had symptoms of CD, 19% (15/79 of student nurses reported the symptoms (p=0.039. The most prevalent positive reaction was to nickel sulfate followed by thimerosal. There was no difference for positive reaction rates between practicing and student nurses. Nurses who had symptoms of CD were older than those without symptoms (p=0.003. The participants with symptoms of CD were more frequently from practicing nurses (p=0.047. Conclusion: CD is more frequent in practicing nurses than student nurses; allergic contact sensitization is not. This may be attributed to the length of occupation that is also correlated well with the length of exposure to the occupational irritants.

  6. Determination of contact maps in proteins: A combination of structural and chemical approaches

    Energy Technology Data Exchange (ETDEWEB)

    Wołek, Karol; Cieplak, Marek, E-mail: mc@ifpan.edu.pl [Institute of Physics, Polish Academy of Science, Al. Lotników 32/46, 02-668 Warsaw (Poland); Gómez-Sicilia, Àngel [Instituto Cajal, Consejo Superior de Investigaciones Cientificas (CSIC), Av. Doctor Arce, 37, 28002 Madrid (Spain); Instituto Madrileño de Estudios Avanzados en Nanociencia (IMDEA-Nanociencia), C/Faraday 9, 28049 Cantoblanco (Madrid) (Spain)

    2015-12-28

    Contact map selection is a crucial step in structure-based molecular dynamics modelling of proteins. The map can be determined in many different ways. We focus on the methods in which residues are represented as clusters of effective spheres. One contact map, denoted as overlap (OV), is based on the overlap of such spheres. Another contact map, named Contacts of Structural Units (CSU), involves the geometry in a different way and, in addition, brings chemical considerations into account. We develop a variant of the CSU approach in which we also incorporate Coulombic effects such as formation of the ionic bridges and destabilization of possible links through repulsion. In this way, the most essential and well defined contacts are identified. The resulting residue-residue contact map, dubbed repulsive CSU (rCSU), is more sound in its physico-chemical justification than CSU. It also provides a clear prescription for validity of an inter-residual contact: the number of attractive atomic contacts should be larger than the number of repulsive ones — a feature that is not present in CSU. However, both of these maps do not correlate well with the experimental data on protein stretching. Thus, we propose to use rCSU together with the OV map. We find that the combined map, denoted as OV+rCSU, performs better than OV. In most situations, OV and OV+rCSU yield comparable folding properties but for some proteins rCSU provides contacts which improve folding in a substantial way. We discuss the likely residue-specificity of the rCSU contacts. Finally, we make comparisons to the recently proposed shadow contact map, which is derived from different principles.

  7. Chemical sensitivity: pathophysiology or pathopsychology?

    Science.gov (United States)

    Genuis, Stephen J

    2013-05-01

    Escalating numbers of people throughout the world are presenting to primary care physicians, allergists, and immunologists with myriad clinical symptoms after low-level exposure to assorted everyday chemicals such as smoke, perfumes, air fresheners, paints, glues, and other products. This clinical state is referred to by various diagnostic labels, including multiple chemical sensitivity disorder, environmental intolerance, chemical sensitivity (CS), and sensitivity-related illness, and has been the subject of much controversy within the health care community. The goal of this study was to provide a brief overview of the etiology, pathogenesis, clinical presentation, and management of CS. An evaluation of the medical community's response to this emerging diagnosis was also explored. This review was prepared by assessing available medical and scientific literature from MEDLINE, as well as by reviewing numerous books, toxicology journals, conference proceedings, government publications, and environmental health periodicals. A primary observation, however, is that there is limited scientific literature available on the issue of CS. The format of a traditional integrated review was chosen because such reviews play a pivotal role in scientific research and professional practice in medical issues with limited primary study and uncharted clinical territory. The sensitization state of CS seems to be initiated by a significant toxic exposure, occurring as a 1-time event, or on surpassing a threshold of toxicity after toxicant accrual from repeated lower-level exposures. Once sensitized through a toxicant-induced loss of tolerance, individuals exposed to inciting triggers such as minute amounts of diverse everyday chemicals may experience various clinical and immune sequelae, sometimes involving lymphocyte, antibody, or cytokine responses. Precautionary avoidance of inciting triggers will prevent symptoms, and desensitization immunotherapy or immune suppression may improve

  8. Encapsulating contact allergens in liposomes, ethosomes, and polycaprolactone may affect their sensitizing properties

    DEFF Research Database (Denmark)

    Madsen, Jakob Torp; Vogel, Stefan; Johansen, Jeanne Duus

    2011-01-01

    Attempts to improve formulation of topical products are a continuing process and the development of micro- and nanovesicular systems as well as polymeric microparticles has led to marketing of topical drugs and cosmetics using these technologies. Encapsulation of some well-known contact allergens...... in ethanolic liposomes have been reported to enhance allergenicity compared with the allergens in similar vehicles without liposomes. The present report includes data on more sensitization studies using the mouse local lymph node assay with three contact allergens encapsulated in different dermal drug...... dichromate compared with control solutions. However, encapsulating the lipophilic contact allergen dinitrochlorobenzene (DNCB) in polycaprolactone reduced the sensitizing capacity to 1211 ± 449 compared with liposomes (7602 ± 2658) and in acetone:olive oil (4:1) (5633 ± 666). The same trend was observed...

  9. The prevalence of allergic contact sensitization in a general population in Tromsø, Norway.

    Science.gov (United States)

    Dotterud, Lars Kåre

    2007-09-01

    This study investigated the prevalence of contact sensitization in a general adult population and the relationship between the history of metal dermatitis and sensitization to metal allergens. A cross-sectional population study using patch tests and a questionnaire was conducted among adults in Tromsø, Northern Norway. A random sample of 830 participants aged 18-75 years were invited to participate in the patch testing and completed a 1-page self-administered questionnaire. Of the adults, 531 (64%) were actually TRUE tested (using a standardized, ready-to-apply patch test system) and completed the self-administered questionnaire about ear piercing, metal reactions, skin reactions to different allergens, atopic dermatitis, eczema, cooking equipment and diet. The study showed that nickel (19.2%; women 31.1% and men 5.0%), fragrance mix (3.4%) and cobalt (1.7%) were the most prevalent allergens causing contact sensitization. For all other allergens, less than 1.1% tested positive. Eighty-four (45.2%) subjects with a positive history of metal dermatitis had negative patch tests. Contact sensitization was found frequently in this general adult population, especially to nickel and perfumes with a predominance among females. An eczematous reaction caused by cheap earrings seemed to be the best indicator for metal sensitivity.

  10. Evaluation of touch-sensitive screen tablet terminal button size and spacing accounting for effect of fingertip contact angle.

    Science.gov (United States)

    Nishimura, T; Doi, K; Fujimoto, H

    2015-08-01

    Touch-sensitive screen terminals enabling intuitive operation are used as input interfaces in a wide range of fields. Tablet terminals are one of the most common devices with a touch-sensitive screen. They have a feature of good portability, enabling use under various conditions. On the other hand, they require a GUI designed to prevent decrease of usability under various conditions. For example, the angle of fingertip contact with the display changes according to finger posture during operation and how the case is held. When a human fingertip makes contact with an object, the contact area between the fingertip and contact object increases or decreases as the contact angle changes. A touch-sensitive screen detects positions using the change in capacitance of the area touched by the fingertip; hence, differences in contact area between the touch-sensitive screen and fingertip resulting from different forefinger angles during operation could possibly affect operability. However, this effect has never been studied. We therefore conducted an experiment to investigate the relationship between size/spacing and operability, while taking the effect of fingertip contact angle into account. As a result, we have been able to specify the button size and spacing conditions that enable accurate and fast operation regardless of the forefinger contact angle.

  11. Clinical update on contact allergy

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Johansen, Jeanne Duus; Orton, David I

    2005-01-01

    PURPOSE OF REVIEW: The aim of this article is to review recent findings in contact allergy, regarding clinical research. RECENT FINDINGS: The biocide methyldibromo glutaronitrile was identified to be an important sensitizer. Subsequently, it was banned from leave-on cosmetics in the European Union...... a classification of newly introduced chemicals; increasingly, the local lymph node assay is supplementing and potentially replacing the guinea pig maximization test. Recent advances in occupational contact allergy include, for example, some attempts to improve diagnostics for epoxy resin and other plastic, glue...

  12. National Prevalence and Effects of Multiple Chemical Sensitivities.

    Science.gov (United States)

    Steinemann, Anne

    2018-03-01

    The aim of this study was to assess the prevalence of multiple chemical sensitivities (MCS), its co-occurrence with asthma and fragrance sensitivity, and effects from exposure to fragranced consumer products. A nationally representative cross-sectional population-based sample of adult Americans (n = 1137) was surveyed in June 2016. Among the population, 12.8% report medically diagnosed MCS and 25.9% report chemical sensitivity. Of those with MCS, 86.2% experience health problems, such as migraine headaches, when exposed to fragranced consumer products; 71.0% are asthmatic; 70.3% cannot access places that use fragranced products such as air fresheners; and 60.7% lost workdays or a job in the past year due to fragranced products in the workplace. Prevalence of diagnosed MCS has increased over 300%, and self-reported chemical sensitivity over 200%, in the past decade. Reducing exposure to fragranced products could help reduce adverse health and societal effects.

  13. TiO{sub 2} films obtained by microwave-activated chemical-bath deposition used to improve TiO{sub 2}-conducting glass contact

    Energy Technology Data Exchange (ETDEWEB)

    Zumeta, I.; Gonzalez, B. [Institute for Material Science and Technology, University of Havana, Colina Universitaria, Ciudad Habana 10 400 (Cuba); Ayllon, J.A.; Domenech, X. [Chemistry Department, Autonomous University of Barcelona, 08290 Cerdanyola del Valles (Spain); Vigil, E. [Institute for Material Science and Technology, University of Havana, Colina Universitaria, Ciudad Habana 10 400 (Cuba); Physics Faculty, University of Havana, Colina Universitaria, Ciudad Habana 10 400 (Cuba)

    2009-10-15

    In traditional solar cells, metal-semiconductor contacts used to extract photogenerated carriers are very important. In dye-sensitized solar cells (DSSC) not much attention has been given to contact between the TiO{sub 2} and the transparent conducting glass (TCO), which is used instead of a metal contact to extract electrons. TiO{sub 2} layers obtained by microwave-activated chemical-bath deposition (MW-CBD) are proposed to improve TiO{sub 2} contact to conducting glass. Spectra of incident photon to current conversion efficiency (IPCE) are obtained for two-photoelectrode TiO{sub 2} photoelectrochemical cells. IPCE spectra show higher values when TiO{sub 2} double layer photoelectrodes are used. In these, the first layer or contacting layer is made by MW-CBD. Best results are obtained for double layer photoelectrodes on FTO (SnO{sub 2}:F) as conducting oxide substrate. Modeling of IPCE spectra reveals the importance of electrical contact and electron extraction rate at the TiO{sub 2}/TCO interface. (author)

  14. An in vitro method for detecting chemical sensitization using human reconstructed skin models and its applicability to cosmetic, pharmaceutical, and medical device safety testing.

    Science.gov (United States)

    McKim, James M; Keller, Donald J; Gorski, Joel R

    2012-12-01

    Chemical sensitization is a serious condition caused by small reactive molecules and is characterized by a delayed type hypersensitivity known as allergic contact dermatitis (ACD). Contact with these molecules via dermal exposure represent a significant concern for chemical manufacturers. Recent legislation in the EU has created the need to develop non-animal alternative methods for many routine safety studies including sensitization. Although most of the alternative research has focused on pure chemicals that possess reasonable solubility properties, it is important for any successful in vitro method to have the ability to test compounds with low aqueous solubility. This is especially true for the medical device industry where device extracts must be prepared in both polar and non-polar vehicles in order to evaluate chemical sensitization. The aim of this research was to demonstrate the functionality and applicability of the human reconstituted skin models (MatTek Epiderm(®) and SkinEthic RHE) as a test system for the evaluation of chemical sensitization and its potential use for medical device testing. In addition, the development of the human 3D skin model should allow the in vitro sensitization assay to be used for finished product testing in the personal care, cosmetics, and pharmaceutical industries. This approach combines solubility, chemical reactivity, cytotoxicity, and activation of the Nrf2/ARE expression pathway to identify and categorize chemical sensitizers. Known chemical sensitizers representing extreme/strong-, moderate-, weak-, and non-sensitizing potency categories were first evaluated in the skin models at six exposure concentrations ranging from 0.1 to 2500 µM for 24 h. The expression of eight Nrf2/ARE, one AhR/XRE and two Nrf1/MRE controlled gene were measured by qRT-PCR. The fold-induction at each exposure concentration was combined with reactivity and cytotoxicity data to determine the sensitization potential. The results demonstrated that

  15. Contact Irritant Responses of Aedes aegypti Using Sublethal Concentration and Focal Application of Pyrethroid Chemicals

    OpenAIRE

    Manda, Hortance; Shah, Pankhil; Polsomboon, Suppaluck; Chareonviriyaphap, Theeraphap; Castro-Llanos, Fanny; Morrison, Amy; Burrus, Roxanne G.; Grieco, John P.; Achee, Nicole L.

    2013-01-01

    BACKGROUND: Previous studies have demonstrated contact irritant and spatial repellent behaviors in Aedes aegypti following exposure to sublethal concentrations of chemicals. These sublethal actions are currently being evaluated in the development of a push-pull strategy for Ae. aegypti control. This study reports on mosquito escape responses after exposure to candidate chemicals for a contact irritant focused push-pull strategy using varying concentrations and focal application. METHODS: Cont...

  16. Contact sensitization from Compositae-containing herbal remedies and cosmetics.

    Science.gov (United States)

    Paulsen, Evy

    2002-10-01

    The Compositae (Asteraceae) family of plants is currently an important cause of allergic plant contact dermatitis in Europe. The family comprises some of the oldest and most valued medicinal plants, and the increasing popularity of herbal medicine and cosmetics may theoretically result in a growing number of Compositae sensitizations from these sources. According to the literature at least 15 species, including among others arnica (Arnica montana), German and Roman chamomile (Chamomilla recutita and Chamaemelum nobile), marigold (Calendula officinalis), Echinacea and elecampane (Inula helenium), have been suspected of sensitization or elicitation of Compositae dermatitis. Epidemiological data are available for 2 species only, arnica and German chamomile, the rest of the evidence being anecdotal. Based on this, sensitization seems to occur relatively frequently with a few species such as arnica and elecampane, and occurs rarely with the majority, especially the widely used German chamomile. Sesquiterpene lactones are the most important allergens, but there are a few cases of sensitization from a coumarin, a sesquiterpene alcohol and a thiophene. The risk of elicitation of dermatitis by using Compositae-containing products in Compositae-sensitive individuals is by-and-large unknown.

  17. Rate and State Friction Relation for Nanoscale Contacts: Thermally Activated Prandtl-Tomlinson Model with Chemical Aging

    Science.gov (United States)

    Tian, Kaiwen; Goldsby, David L.; Carpick, Robert W.

    2018-05-01

    Rate and state friction (RSF) laws are widely used empirical relationships that describe macroscale to microscale frictional behavior. They entail a linear combination of the direct effect (the increase of friction with sliding velocity due to the reduced influence of thermal excitations) and the evolution effect (the change in friction with changes in contact "state," such as the real contact area or the degree of interfacial chemical bonds). Recent atomic force microscope (AFM) experiments and simulations found that nanoscale single-asperity amorphous silica-silica contacts exhibit logarithmic aging (increasing friction with time) over several decades of contact time, due to the formation of interfacial chemical bonds. Here we establish a physically based RSF relation for such contacts by combining the thermally activated Prandtl-Tomlinson (PTT) model with an evolution effect based on the physics of chemical aging. This thermally activated Prandtl-Tomlinson model with chemical aging (PTTCA), like the PTT model, uses the loading point velocity for describing the direct effect, not the tip velocity (as in conventional RSF laws). Also, in the PTTCA model, the combination of the evolution and direct effects may be nonlinear. We present AFM data consistent with the PTTCA model whereby in aging tests, for a given hold time, static friction increases with the logarithm of the loading point velocity. Kinetic friction also increases with the logarithm of the loading point velocity at sufficiently high velocities, but at a different increasing rate. The discrepancy between the rates of increase of static and kinetic friction with velocity arises from the fact that appreciable aging during static contact changes the energy landscape. Our approach extends the PTT model, originally used for crystalline substrates, to amorphous materials. It also establishes how conventional RSF laws can be modified for nanoscale single-asperity contacts to provide a physically based friction

  18. Hall effect enhanced low-field sensitivity in a three-contact extraordinary magnetoresistance sensor

    KAUST Repository

    Sun, Jian

    2012-06-06

    An extraordinary magnetoresistance (EMR) device with a 3-contact geometry has been fabricated and characterized. A large enhancement of the output sensitivity at low magnetic fields compared to the conventional EMR device has been found, which can be attributed to an additional influence coming from the Hall effect. Output sensitivities of 0.19 mV/T at zero-field and 0.2 mV/T at 0.01 T have been measured in the device, which is equivalent to the ones of the conventional EMR sensors with a bias of ∼0.04 T. The exceptional performance of EMR sensors in the high field region is maintained in the 3-contact device.

  19. HMOX1 and NQO1 genes are upregulated in response to contact sensitizers in dendritic cells and THP-1 cell line: role of the Keap1/Nrf2 pathway.

    Science.gov (United States)

    Ade, Nadège; Leon, Fanny; Pallardy, Marc; Peiffer, Jean-Luc; Kerdine-Romer, Saadia; Tissier, Marie-Hélène; Bonnet, Pierre-Antoine; Fabre, Isabelle; Ourlin, Jean-Claude

    2009-02-01

    Electrophilicity is one of the most common features of skin contact sensitizers and is necessary for protein haptenation. The Keap1 (Kelch-like ECH-associated protein 1)/Nrf2 -signaling pathway is dedicated to the detection of electrophilic stress in cells leading to the upregulation of genes involved in protection or neutralization of chemical reactive species. Signals provided by chemical stress could play an important role in dendritic cell activation and the aim of this work was to test whether contact sensitizers were specific activators of the Keap1/Nrf2 pathway. CD34-derived dendritic cells (CD34-DC) and the THP-1 myeloid cell line were treated by a panel of sensitizers (Ni, 1-chloro 2,4-dinitrobenzene, cinnamaldehyde, 7-hydroxycitronellal, 1,4-dihydroquinone, alpha-methyl-trans-cinnamaldehyde, 2-4-tert-(butylbenzyl)propionaldehyde or Lilial, and 1,4-phenylenediamine), irritants (sodium dodecyl sulfate, benzalkonium chloride), and a nonsensitizer molecule (chlorobenzene). Three well-known Nrf2 activators (tert-butylhydroquinone, lipoic acid, sulforaphane) were also tested. Expression of hmox1 and nqo1 was measured using real-time PCR and cellular accumulation of Nrf2 was assessed by Western blot. Our results showed an increased expression at early time points of hmox1 and nqo1 mRNAs in response to sensitizers but not to irritants. Accumulation of the Nrf2 protein was also observed only with chemical sensitizers. A significant inhibition of the expression of hmox1 and nqo1 mRNAs and CD86 expression was found in 1-chloro 2,4-dinitrobenzene-treated THP-1 cells preincubated with N-acetyl cysteine, a glutathione precursor. Altogether, these data suggested that the Keap1/Nrf2-signaling pathway was activated by electrophilic molecules including sensitizers in dendritic cells and in the THP-1 cell line. Monitoring of this pathway may provide new biomarkers (e.g., Nrf2, hmox1) for the detection of the sensitization potential of chemicals.

  20. Occupational contact sensitization in female geriatric nurses: Data of the Information Network of Departments of Dermatology (IVDK) 2005-2014.

    Science.gov (United States)

    Schubert, S; Bauer, A; Molin, S; Skudlik, C; Geier, J

    2017-03-01

    Geriatric nurses (GN) have a high risk of occupational contact dermatitis (OCD), with chronic irritant contact dermatitis predominating. However, allergic contact dermatitis is an important issue as well. Little is known whether the relevant occupational allergen spectrum reported in the 1990s, including fragrances, preservatives, rubber chemicals and ingredients of surface disinfectants to be the most common sensitizers in GN, is still valid. To monitor the current allergen spectrum in GN with OCD and verify the validity of the patch test recommendations (baseline-, preservative-, ointment base-, rubber-, disinfectant, series and fragrances) in GN with suspected OCD given by the German Contact Dermatitis Research Group (DKG). Retrospective analysis of IVDK data (2005-2014) of 743 female GN with OCD, in comparison to 695 GN without OCD. GN with OCD reacted significantly more frequently to both fragrance mixes, hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC), thiuram mix, zinc diethyldithiocarbamate and mercaptobenzothiazole than GN without OCD. Reactions to MDBGN, methylchloroisothiazolinone/methylisothiazolinone and oil of turpentine occurred substantially, but not significantly more frequently among GN with OCD. The latter may be due to former use of a special alcoholic liniment in geriatric care. Among material from the patients' workplaces, tetrazepam was a frequent allergen, due to dust exposure from pill crushing. Furthermore, occupationally used protective gloves, body care products as well as surface disinfectants were often tested positively. The general allergen spectrum in GN with OCD is unchanged, so the DKG patch test recommendations are still valid. Prevention of occupational sensitization should focus on fragrance-free hygiene and body care products, usage of accelerator-free protective gloves and avoidance of drug dust exposure. © 2016 European Academy of Dermatology and Venereology.

  1. Chemical allergy in humans

    DEFF Research Database (Denmark)

    Kimber, Ian; Basketter, David A; Thyssen, Jacob P

    2014-01-01

    Abstract There is considerable interest in the immunobiological processes through which the development of allergic sensitization to chemicals is initiated and orchestrated. One of the most intriguing issues is the basis for the elicitation by chemical sensitizers of different forms of allergic...... reaction; that is, allergic contact dermatitis or sensitization of the respiratory tract associated with occupational asthma. Studies in rodents have revealed that differential forms of allergic sensitization to chemicals are, in large part at least, a function of the selective development of discrete...... functional sub-populations of CD4(+) and CD8(+) T-lymphocytes. Evidence for a similar association of chemical allergy in humans with discrete T-lymphocyte populations is, however, limited. It is of some interest, therefore, that two recent articles from different teams of investigators have shed new light...

  2. Contact sensitization in Dutch children and adolescents with and without atopic dermatitis - a retrospective analysis

    NARCIS (Netherlands)

    Lubbes, Stefanie; Rustemeyer, Thomas; Smitt, Johannes H. Sillevis; Schuttelaar, Marie-Louise A.; Middelkamp-Hup, Maritza A

    Background. Allergic contact dermatitis is known to occur in children with and without atopic dermatitis, but more data are needed on contact sensitization profiles in these two groups. Objectives. To identify frequent allergens in children with and without atopic dermatitis suspected of having

  3. Non-allergic cutaneous reactions in airborne chemical sensitivity--a population based study.

    Science.gov (United States)

    Berg, Nikolaj Drimer; Linneberg, Allan; Thyssen, Jacob Pontoppidan; Dirksen, Asger; Elberling, Jesper

    2011-06-01

    Multiple chemical sensitivity (MCS) is characterised by adverse effects due to exposure to low levels of chemical substances. The aetiology is unknown, but chemical related respiratory symptoms have been found associated with positive patch test. The purpose of this study was to investigate the relationship between cutaneous reactions from patch testing and self-reported severity of chemical sensitivity to common airborne chemicals. A total of 3460 individuals participating in a general health examination, Health 2006, were patch tested with allergens from the European standard series and screened for chemical sensitivity with a standardised questionnaire dividing the participants into four severity groups of chemical sensitivity. Both allergic and non-allergic cutaneous reactions--defined as irritative, follicular, or doubtful allergic reactions--were analysed in relationship with severity of chemical sensitivity. Associations were controlled for the possible confounding effects of sex, age, asthma, eczema, atopic dermatitis, psychological and social factors, and smoking habits. In unadjusted analyses we found associations between allergic and non-allergic cutaneous reactions on patch testing and the two most severe groups of self-reported sensitivity to airborne chemicals. When adjusting for confounding, associations were weakened, and only non-allergic cutaneous reactions were significantly associated with individuals most severely affected by inhalation of airborne chemicals (odds ratio = 2.5, p = 0.006). Our results suggest that individuals with self-reported chemical sensitivity show increased non-allergic cutaneous reactions based on day 2 readings of patch tests. Copyright © 2011 Elsevier GmbH. All rights reserved.

  4. Contact irritant responses of Aedes aegypti Using sublethal concentration and focal application of pyrethroid chemicals.

    Science.gov (United States)

    Manda, Hortance; Shah, Pankhil; Polsomboon, Suppaluck; Chareonviriyaphap, Theeraphap; Castro-Llanos, Fanny; Morrison, Amy; Burrus, Roxanne G; Grieco, John P; Achee, Nicole L

    2013-01-01

    Previous studies have demonstrated contact irritant and spatial repellent behaviors in Aedes aegypti following exposure to sublethal concentrations of chemicals. These sublethal actions are currently being evaluated in the development of a push-pull strategy for Ae. aegypti control. This study reports on mosquito escape responses after exposure to candidate chemicals for a contact irritant focused push-pull strategy using varying concentrations and focal application. Contact irritancy (escape) behavior, knockdown and 24 hour mortality rates were quantified in populations of female Ae. aegypti under laboratory conditions and validated in the field (Thailand and Peru) using experimental huts. Evaluations were conducted using varying concentrations and treatment surface area coverage (SAC) of three pyrethroid insecticides: alphacypermethrin, lambacyhalothrin and deltamethrin. Under laboratory conditions, exposure of Ae. aegypti to alphacypermethrin using the standard field application rate (FAR) resulted in escape responses at 25% and 50% SAC that were comparable with escape responses at 100% SAC. Significant escape responses were also observed at time of exit (by four hours) and 40% increase in escape using ½FAR of alphacypermethrin at 75% SAC compared to a matched chemical-free control. In Peru, however, the maximum increase in Ae. aegypti escape from alphacypermethrin-treated huts was 11%. Results presented here suggest a potential role for sublethal and focal application of contact irritant chemicals in an Ae. aegypti push-pull strategy to reduce human-vector contact inside treated homes. However, the impact of an increase in escape response on dengue virus transmission is currently unknown and will depend on rate of biting on human hosts prior to house exiting.

  5. Can We Make Cosmetic Contact Allergy History?

    Directory of Open Access Journals (Sweden)

    David Basketter

    2016-03-01

    Full Text Available Chemical allergy is of considerable importance to the toxicologist, who, amongst other things, has the responsibility of identifying and characterizing the skin (and respiratory sensitizing potential of chemicals, and estimating the risk they pose to human health. Allergic contact dermatitis (ACD is to a large extent a preventable disease. Although quantitative risk assessment (QRA for contact allergy can be performed, it is reasonable to ask why the burden of the skin disease ACD appears to remain stubbornly high, and in particular, that the general level of ACD to sensitizing ingredients found in cosmetics has not fallen noticeably over recent decades; some could argue that it has increased. In this review, this conundrum is addressed, considering whether and to what extent the prevalence of cosmetic allergy is truly unchanged, whether the predicted test methods and potency estimations are sufficiently precise and how proposed changes to the QRA process (i.e., cumulative exposure may ameliorate the situation. Improved and more widespread use of risk assessment, better education of risk assessors, better post-marketing surveillance and monitoring of dermatology clinic feedback to improve QRA, all together could help to “make contact allergy history”.

  6. Two Cases of Occupational Contact Urticaria Caused by Percutaneous Sensitization to Parvalbumin

    Directory of Open Access Journals (Sweden)

    Akiyo Sano

    2015-08-01

    Full Text Available Background: In recent years, it has been proposed that the primary mechanism for the development of food allergies is percutaneous sensitization. Since 2010, in Japan, the number of immediate-type wheat allergy due to hydrolyzed wheat protein has dramatically increased among those who have been using soap containing hydrolyzed wheat. This incidence supports the hypothesis that food allergens arise through percutaneous sensitization. Clinical Summary: A 25-year-old man (case 1 and an 18-year-old girl (case 2 with atopic dermatitis visited our Department because of food allergy and hand eczema. After starting their work with fish, severe itchy eczema appeared on their hands. They subsequently started to experience oral allergic symptoms, intraoral itchiness and dyspnea after eating fish. Specific IgE antibodies were detected for many fishes, and skin prick tests showed positive reactions for a variety of fishes in both cases. Furthermore, the fluorescence intensities of specific IgE antibodies against parvalbumin from various types of fish in microarray immunoassay analysis showed positive reactions. We diagnosed them as contact urticaria caused by percutaneous sensitization to parvalbumin through job-related physical contact with fish. Conclusion: The patients' histories and findings indicate the possibility of percutaneous sensitization through occupational exposure to parvalbumin, leading to food allergy.

  7. Two Cases of Occupational Contact Urticaria Caused by Percutaneous Sensitization to Parvalbumin.

    Science.gov (United States)

    Sano, Akiyo; Yagami, Akiko; Suzuki, Kayoko; Iwata, Yohei; Kobayashi, Tsukane; Arima, Masaru; Kondo, Yasuto; Yoshikawa, Tetsushi; Matsunaga, Kayoko

    2015-01-01

    In recent years, it has been proposed that the primary mechanism for the development of food allergies is percutaneous sensitization. Since 2010, in Japan, the number of immediate-type wheat allergy due to hydrolyzed wheat protein has dramatically increased among those who have been using soap containing hydrolyzed wheat. This incidence supports the hypothesis that food allergens arise through percutaneous sensitization. A 25-year-old man (case 1) and an 18-year-old girl (case 2) with atopic dermatitis visited our Department because of food allergy and hand eczema. After starting their work with fish, severe itchy eczema appeared on their hands. They subsequently started to experience oral allergic symptoms, intraoral itchiness and dyspnea after eating fish. Specific IgE antibodies were detected for many fishes, and skin prick tests showed positive reactions for a variety of fishes in both cases. Furthermore, the fluorescence intensities of specific IgE antibodies against parvalbumin from various types of fish in microarray immunoassay analysis showed positive reactions. We diagnosed them as contact urticaria caused by percutaneous sensitization to parvalbumin through job-related physical contact with fish. The patients' histories and findings indicate the possibility of percutaneous sensitization through occupational exposure to parvalbumin, leading to food allergy.

  8. Non-allergic cutaneous reactions in airborne chemical sensitivity--a population based study

    DEFF Research Database (Denmark)

    Berg, Nikolaj Drimer; Linneberg, Allan; Thyssen, Jacob Pontoppidan

    2011-01-01

    the relationship between cutaneous reactions from patch testing and self-reported severity of chemical sensitivity to common airborne chemicals. A total of 3460 individuals participating in a general health examination, Health 2006, were patch tested with allergens from the European standard series and screened...... for chemical sensitivity with a standardised questionnaire dividing the participants into four severity groups of chemical sensitivity. Both allergic and non-allergic cutaneous reactions--defined as irritative, follicular, or doubtful allergic reactions--were analysed in relationship with severity of chemical...... most severe groups of self-reported sensitivity to airborne chemicals. When adjusting for confounding, associations were weakened, and only non-allergic cutaneous reactions were significantly associated with individuals most severely affected by inhalation of airborne chemicals (odds ratio = 2.5, p = 0...

  9. Long-Term Stability of Oxide Nanowire Sensors via Heavily Doped Oxide Contact.

    Science.gov (United States)

    Zeng, Hao; Takahashi, Tsunaki; Kanai, Masaki; Zhang, Guozhu; He, Yong; Nagashima, Kazuki; Yanagida, Takeshi

    2017-12-22

    Long-term stability of a chemical sensor is an essential quality for long-term collection of data related to exhaled breath, environmental air, and other sources in the Internet of things (IoT) era. Although an oxide nanowire sensor has shown great potential as a chemical sensor, the long-term stability of sensitivity has not been realized yet due to electrical degradation under harsh sensing conditions. Here, we report a rational concept to accomplish long-term electrical stability of metal oxide nanowire sensors via introduction of a heavily doped metal oxide contact layer. Antimony-doped SnO 2 (ATO) contacts on SnO 2 nanowires show much more stable and lower electrical contact resistance than conventional Ti contacts for high temperature (200 °C) conditions, which are required to operate chemical sensors. The stable and low contact resistance of ATO was confirmed for at least 1960 h under 200 °C in open air. This heavily doped oxide contact enables us to realize the long-term stability of SnO 2 nanowire sensors while maintaining the sensitivity for both NO 2 gas and light (photo) detections. The applicability of our method is confirmed for sensors on a flexible polyethylene naphthalate (PEN) substrate. Since the proposed fundamental concept can be applied to various oxide nanostructures, it will give a foundation for designing long-term stable oxide nanomaterial-based IoT sensors.

  10. Keratinocyte gene expression profiles discriminate sensitizing and irritating compounds

    NARCIS (Netherlands)

    Briel, R.J. van de; Pennings, J.L.A.; Baken, K.A.; Pronk, T.E.; Boorsma, A.; Gottschalk, R.; Loveren, H. van

    2010-01-01

    Many chemicals can induce allergic contact dermatitis. Because evaluation of skin sensitizing potential by animal testing is prohibited for cosmetics, and screening of many chemicals is required within Registration, Evaluation, Authorisation and Restriction of Chemicals, urgent need exists for

  11. Environmental issues and work: women with multiple chemical sensitivities.

    Science.gov (United States)

    Lipson, Juliene G; Doiron, Nathalie

    2006-08-01

    Multiple chemical sensitivities (MCS) is an acquired condition in which exposure to low levels of chemicals causes symptoms in multiple organ systems. Some 12%-16% of the U.S. population has some level of chemical sensitivity, 80% of whom are women. Attempts to reduce chemical exposures leads to enormous life difficulties at home, school, and workplace. We base our article on an ethnographic study of MCS in the United States and Canada. We describe here themes related to work issues in terms of a general trajectory of becoming sick from work exposures, coping with toxic physical environments and dealing with coworkers and, when unable to continue working, applying for workers' compensation, or disability status, or both.

  12. The Possible Role of Contact Sensitization to Fragrances and Preservatives in Poikiloderma of Civatte

    OpenAIRE

    Khunkhet S; Wattanakrai P

    2014-01-01

    Numerous mechanisms have been postulated to play an important role in the pathogenesis of poikiloderma of Civatte, including chronic exposure to ultraviolet radiation, menopause-related hormonal changes, contact hypersensitivity and genetic predisposition. Herein, we report a case of contact sensitization to fragrances and commonly used preservatives, methylchloroisothiazolinone and methylisothiazolinone, also widely known as Kathon CG, in a post-menopausal woman with poikiloderma of Civatte,...

  13. The Possible Role of Contact Sensitization to Fragrances and Preservatives in Poikiloderma of Civatte

    OpenAIRE

    Khunkhet, Saranya; Wattanakrai, Penpun

    2014-01-01

    Numerous mechanisms have been postulated to play an important role in the pathogenesis of poikiloderma of Civatte (PC), including chronic exposure to ultraviolet radiation, menopause-related hormonal changes, contact hypersensitivity and genetic predisposition. Herein, we report a case of contact sensitization to fragrances and commonly used preservatives, methylchloroisothiazolinone and methylisothiazolinone, also widely known as Kathon CG, in a post-menopausal woman with PC, who denied exce...

  14. Identification of Lilial as a fragrance sensitizer in a perfume by bioassay-guided chemical fractionation and structure-activity relationships

    DEFF Research Database (Denmark)

    Arnau, E G; Andersen, Klaus Ejner; Bruze, M

    2000-01-01

    Fragrance materials are among the most common causes of allergic contact dermatitis. The aim of this study was to identify in a perfume fragrance allergens not included in the fragrance mix, by use of bioassay-guided chemical fractionation and chemical analysis/structure-activity relationships...... (SARs). The basis for the investigation was a 45-year-old woman allergic to her own perfume. She had a negative patch test to the fragrance mix and agreed to participate in the study. Chemical fractionation of the perfume concentrate was used for repeated patch testing and/or repeated open application......" in their chemical structure, indicating an ability to modify skin proteins and thus behave as a skin sensitizer, were tested on the patient. The patient reacted positively to the synthetic fragrance p-t-butyl-alpha-methylhydrocinnamic aldehyde (Lilial), a widely used fragrance compound not present in the fragrance...

  15. Contact allergy to popular perfumes; assessed by patch test, use test and chemical analysis

    DEFF Research Database (Denmark)

    Johansen, J D; Rastogi, Suresh Chandra; Menné, T

    1996-01-01

    The frequency of contact allergy to the 10 best-selling women's perfumes was studied in 335 consecutive female eczema patients by patch testing. The diagnostic ability of the fragrance mix, in relation to these products, was evaluated. Of eczema patients, 6.9% had a positive patch test to one...... or more of the perfumes, and 56.5% of these had a concurrent positive reaction to the fragrance mix. Hence, testing with the patients' own cosmetics is a significant part of diagnosing perfume allergy. The clinical relevance of the patch-test reactions to the commercial perfumes was equal...... to that of the fragrance mix, as judged from the patient's history and use testing with one of the perfumes. At least three of the chemically defined sensitizers in the fragrance mix were detected in all the perfumes by gas chromatography-mass spectrometry, which indicates that the fragrance mix is a good imitation...

  16. Contact irritant responses of Aedes aegypti Using sublethal concentration and focal application of pyrethroid chemicals.

    Directory of Open Access Journals (Sweden)

    Hortance Manda

    Full Text Available BACKGROUND: Previous studies have demonstrated contact irritant and spatial repellent behaviors in Aedes aegypti following exposure to sublethal concentrations of chemicals. These sublethal actions are currently being evaluated in the development of a push-pull strategy for Ae. aegypti control. This study reports on mosquito escape responses after exposure to candidate chemicals for a contact irritant focused push-pull strategy using varying concentrations and focal application. METHODS: Contact irritancy (escape behavior, knockdown and 24 hour mortality rates were quantified in populations of female Ae. aegypti under laboratory conditions and validated in the field (Thailand and Peru using experimental huts. Evaluations were conducted using varying concentrations and treatment surface area coverage (SAC of three pyrethroid insecticides: alphacypermethrin, lambacyhalothrin and deltamethrin. RESULTS: Under laboratory conditions, exposure of Ae. aegypti to alphacypermethrin using the standard field application rate (FAR resulted in escape responses at 25% and 50% SAC that were comparable with escape responses at 100% SAC. Significant escape responses were also observed at <100% SAC using ½FAR of all test compounds. In most trials, KD and 24 hour mortality rates were higher in mosquitoes that did not escape than in those that escaped. In Thailand, field validation studies indicated an early time of exit (by four hours and 40% increase in escape using ½FAR of alphacypermethrin at 75% SAC compared to a matched chemical-free control. In Peru, however, the maximum increase in Ae. aegypti escape from alphacypermethrin-treated huts was 11%. CONCLUSIONS/SIGNIFICANCE: Results presented here suggest a potential role for sublethal and focal application of contact irritant chemicals in an Ae. aegypti push-pull strategy to reduce human-vector contact inside treated homes. However, the impact of an increase in escape response on dengue virus transmission is

  17. The cytokine-dependent MUTZ-3 cell line as an in vitro model for the screening of contact sensitizers

    International Nuclear Information System (INIS)

    Azam, Philippe; Peiffer, Jean-Luc; Chamousset, Delphine; Tissier, Marie-Helene; Bonnet, Pierre-Antoine; Vian, Laurence; Fabre, Isabelle; Ourlin, Jean-Claude

    2006-01-01

    Langerhans cells (LC) are key mediators of contact allergenicity in the skin. However, no in vitro methods exist which are based on the activation process of LC to predict the sensitization potential of chemicals. In this study, we have evaluated the performances of MUTZ-3, a cytokine-dependent human monocytic cell line, in its response to sensitizers. First, we compared undifferentiated MUTZ-3 cells with several standard human cells such as THP-1, KG-1, HL-60, K-562, and U-937 in their response to the strong sensitizer DNCB and the irritant SDS by monitoring the expression levels of HLA-DR, CD54, and CD86 by flow cytometry. Only MUTZ-3 and THP-1 cells show a strong and specific response to sensitizer, while other cell lines showed very variable responses. Then, we tested MUTZ-3 cells against a wider panel of sensitizers and irritants on a broader spectrum of cell surface markers (HLA-DR, CD40, CD54, CD80, CD86, B7-H1, B7-H2, B7-DC). Of these markers, CD86 proved to be the most reliable since it detected all sensitizers, including benzocaine, a classical false negative in local lymph node assay (LLNA) but not irritants. We confirmed the MUTZ-3 response to DNCB by real-time PCR analysis. Taken together, our data suggest that undifferentiated MUTZ-3 cells may represent a valuable in vitro model for the screening of potential sensitizers

  18. Safety Evaluation of Cosmetic Ingredients: In Vitro Opportunities for the Identification of Contact Allergens

    Directory of Open Access Journals (Sweden)

    Emanuela Corsini

    2014-03-01

    Full Text Available Irritant and allergic contact dermatitis are undesired side effects in the development of drugs and cosmetics as well as after contact with environmental or industrial chemicals. Over the last decades, a great deal of progress has been made in the development of alternative In vitro test to assess these issues. Driven by the 7th Amendment to the European Cosmetic Directive, the EU policy on chemicals (the registration, evaluation, authorization and restriction of chemicals (REACH system, the update of the European legislation on the protection of animals used in research, and emerging visions and strategies for predicting toxicity, in vitro methods are likely to play a major role in the near future. On 12 December 2013, the European Union Reference Laboratory for Alternatives to Animal Testing (EURL ECVAM, part of the European Commission Joint Research Centre published its Recommendation on the Direct Peptide Reactivity Assay (DPRA for skin sensitization, capable of distinguishing sensitizers from non-sensitizers. Other assays (i.e., KeratinoSens™ assay will follow shortly. While a number of methods are at various stages of development and use, currently it is not possible to rank chemicals for their sensitizing potency, an issue that is important for a full safety assessment. It is expected that a predictive method to totally replace animal testing will be in the form of a test battery comprising molecular, cell-based, and/or computational methods, the so-called “Integrated Approaches to Testing and Assessment”. This review aims to discuss the state-of-the-art in the field of in vitro assessment of contact sensitizers.

  19. Immunological, chemical and clinical aspects of exposure to mixtures of contact allergens

    DEFF Research Database (Denmark)

    Bonefeld, Charlotte M.; Geisler, Carsten; Gimenéz-Arnau, Elena

    2017-01-01

    relevant. In this article, we provide a general introduction to immune responses to contact allergens, and discuss the literature concerning immune responses to mixtures of allergens. According to the existing evidence, increased responses are induced following sensitization with combinations of allergens...

  20. ER-mitochondria contacts control surface glycan expression and sensitivity to killer lymphocytes in glioma stem-like cells.

    Science.gov (United States)

    Bassoy, Esen Yonca; Kasahara, Atsuko; Chiusolo, Valentina; Jacquemin, Guillaume; Boydell, Emma; Zamorano, Sebastian; Riccadonna, Cristina; Pellegatta, Serena; Hulo, Nicolas; Dutoit, Valérie; Derouazi, Madiha; Dietrich, Pierre Yves; Walker, Paul R; Martinvalet, Denis

    2017-06-01

    Glioblastoma is a highly heterogeneous aggressive primary brain tumor, with the glioma stem-like cells (GSC) being more sensitive to cytotoxic lymphocyte-mediated killing than glioma differentiated cells (GDC). However, the mechanism behind this higher sensitivity is unclear. Here, we found that the mitochondrial morphology of GSCs modulates the ER-mitochondria contacts that regulate the surface expression of sialylated glycans and their recognition by cytotoxic T lymphocytes and natural killer cells. GSCs displayed diminished ER-mitochondria contacts compared to GDCs. Forced ER-mitochondria contacts in GSCs increased their cell surface expression of sialylated glycans and reduced their susceptibility to cytotoxic lymphocytes. Therefore, mitochondrial morphology and dynamism dictate the ER-mitochondria contacts in order to regulate the surface expression of certain glycans and thus play a role in GSC recognition and elimination by immune effector cells. Targeting the mitochondrial morphology, dynamism, and contacts with the ER could be an innovative strategy to deplete the cancer stem cell compartment to successfully treat glioblastoma. © 2017 The Authors.

  1. An epidermal equivalent assay for identification and ranking potency of contact sensitizers

    NARCIS (Netherlands)

    Gibbs, S.; Corsini, E.; Spiekstra, S.W.; Galbiati, V.; Fuchs, H.W.; Degeorge, G.; Troese, M.; Hayden, P.; Deng, W.; Roggen, E.

    2013-01-01

    The purpose of this study was to explore the possibility of combining the epidermal equivalent (EE) potency assay with the assay which assesses release of interleukin-18 (IL-18) to provide a single test for identification and classification of skin sensitizing chemicals, including chemicals of low

  2. Contact sensitivity to newsprint: a rare manifestation of coal tar allergy

    Energy Technology Data Exchange (ETDEWEB)

    Illchyshyn, A; Cartwright, P H; Smith, A G

    1987-07-01

    Contact dermatitis due to coal tar is infrequently reported in spite of the fact that it consists of a mixture of 10,000 constituents, and is still often used to treat both eczema and psoriasis. Discusses patient with coal tar sensitivity in whom the source of exacerbation of her dermatitis is shown to be newsprint, a common product containing coal tar-derived material. 6 refs.

  3. Identifying sensitive areas on intercultural contacts: An exploratory study

    Directory of Open Access Journals (Sweden)

    Ignacio Ramos-Vidal

    2011-06-01

    Full Text Available This paper analyzes the negative influence that cultural friction areas can promote on intercultural contacts. First, we expose the critical incident method like cross-cultural training model (Arthur, 2001. Then we show the negative effects that sensitive cultural zones can exert on the formation of prejudices and stereotypes about culturally diverse groups, analyzing 77 critical incidents collected in two different formative contexts. The main cultural shock areas detected are a intercultural communication barriers, b gender roles, and c the cultural expressions statement. Strategies to improve the method validity are proposed.

  4. Contact allergy to popular perfumes; assessed by patch test, use test and chemical analysis.

    Science.gov (United States)

    Johansen, J D; Rastogi, S C; Menné, T

    1996-09-01

    The frequency of contact allergy to the 10 best-selling women's perfumes was studied in 335 consecutive female eczema patients by patch testing. The diagnostic ability of the fragrance mix, in relation to these products, was evaluated. Of eczema patients, 6.9% had a positive patch test to one or more of the perfumes, and 56.5% of these had a concurrent positive reaction to the fragrance mix. Hence, testing with the patients' own cosmetics is a significant part of diagnosing perfume allergy. The clinical relevance of the patch-test reactions to the commercial perfumes was equal to that of the fragrance mix, as judged from the patient's history and use testing with one of the perfumes. At least three of the chemically defined sensitizers in the fragrance mix were detected in all the perfumes by gas chromatography-mass spectrometry, which indicates that the fragrance mix is a good imitation of actual exposure.

  5. Assessment of the U937 cell line for the detection of contact allergens

    International Nuclear Information System (INIS)

    Python, Francois; Goebel, Carsten; Aeby, Pierre

    2007-01-01

    The human myeloid cell line U937 was evaluated as an in vitro test system to identify contact sensitizers in order to develop alternatives to animal tests for the cosmetic industry. Specific culture conditions (i.e., presence of interleukin-4, IL-4) were applied to obtain a dendritic cell-like phenotype. In the described test protocol, these cells were exposed to test chemicals and then analyzed by flow cytometry for CD86 expression and by quantitative real-time reverse transcriptase-polymerase chain reaction for IL-1β and IL-8 gene expressions. Eight sensitizers, three non-sensitizers and five oxidative hair dye precursors were examined after 24-, 48- and 72-h exposure times. Test item-specific modulations of the chosen activation markers (CD86, IL-1β and IL-8) suggest that this U937 activation test could discriminate test items classified as contact sensitizers or non-sensitizers in the local lymph node assay in mice (LLNA). More specifically, a test item can be considered as a potential sensitizer when it significantly induced the upregulation of the expression of at least two markers. Using this approach, we could correctly evaluate the dendritic cell (DC) activation potential for 15 out of 16 tested chemicals. We conclude that the U937 activation test may represent an useful tool in a future in vitro test battery for predicting sensitizing properties of chemicals

  6. Evaluation of human skin tests for potential dermal irritant and contact sensitizing products: a position paper

    NARCIS (Netherlands)

    Loveren H van; Jong WH de; Garssen J; LPI

    1998-01-01

    Prediction of human cutaneous irritation and sensitization in view of hazard identification has primarily relied on the use of laboratory animals. Such studies in laboratory animals have been very instrumental in the detection of potential contact sensitizing agents. There are however many

  7. Further important sensitizers in patients sensitive to fragrances

    DEFF Research Database (Denmark)

    Frosch, Peter J; Johansen, J D; Menné, T

    2002-01-01

    (series I). Each patient was classified regarding a history of adverse reactions to fragrances: certain, probable, questionable, none. Reactions to FM occurred in 11.3% of the subjects. The 6 substances with the highest reactivity following FM were Lyral (2.7%), citral (1.1%), farnesol P (0...... further sensitizers relevant for patch testing of patients with contact dermatitis, of which Lyral is the most important single chemical....

  8. Local lymph node activation in rats after dermal application of the sensitizers 2,4-dinitrochlorobenzene and trimellitic anhydride

    NARCIS (Netherlands)

    Arts, J.H.E.; Dröge, S.C.M.; Bloksma, N.; Kuper, C.F.

    1996-01-01

    Five rat strains were compared for their performance in the local lymph node assay (LLNA) a promising test system for the identification of the skin-sensitizing potential of chemicals in the mouse. The contact sensitizer 2,4-dinitrochlorobenzene (DNCB) and the contact and respiratory sensitizer

  9. Screening for skin-sensitizing allergens among patients with clinically suspected allergic contact dermatitis

    Directory of Open Access Journals (Sweden)

    Zahid Shakoor

    2017-09-01

    Full Text Available Objectives: To detect common skin-sensitizing agents among patients experiencing allergic contact dermatitis (ACD. Methods: This was a retrospective study of 152 patients with clinically suspected ACD who underwent patch testing in an allergy clinic at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia between January 2012 and February 2015. Of these patients, only 74 (48% patients reacted to one or more contact allergens. This group of patients included 58 (78.4% women and 16 (21.6% men (mean age: 37.8±13.8 years. Patch testing was performed using the thin-layer rapid-use epicutaneous patch test panels. Results: Nickel sulfate was the most common sensitizing agent, with 26 (35.1% patients yielding a positive result; followed by p-phenylenediamine in 17 (22.9%, butyl-tetra-phenol formaldehyde in 12 (16.2%, gold sodium thiosulfate in 10 (13.5%, and thimerosal in 6 (8.1% patients. Nickel reactivity was significantly higher among women (41.4% than among men (12.5% (p less than 0.0001. Similarly, gold reactivity among women (15.5% was also higher than among men (6.2% (p≤0.02. Conclusion: The high level of skin sensitization due to nickel, PPD, and gold in patients with ACD emphasizes the need for measures to decrease exposure to these sensitizing agents.

  10. Stick-Slip Motion of Moving Contact Line on Chemically Patterned Surfaces

    KAUST Repository

    Wu, Congmin; Lei, Siulong; Qian, Tiezheng; Wang, Xiaoping

    2009-01-01

    Based on our continuum hydrodynamic model for immiscible two-phase flows at solid surfaces, the stick-slip motion has been predicted for moving contact line at chemically patterned surfaces [Wang et al., J. Fluid Mech., 605 (2008), pp. 59-78]. In this paper we show that the continuum predictions can be quantitatively verified by molecular dynamics (MD) simulations. Our MD simulations are carried out for two immiscible Lennard-Jones fluids confined by two planar solid walls in Poiseuille flow geometry. In particular, one solid surface is chemically patterned with alternating stripes. For comparison, the continuum model is numerically solved using material parameters directly measured in MD simulations. From oscillatory fluid-fluid interface to intermittent stick-slip motion of moving contact line, we have quantitative agreement between the continuum and MD results. This agreement is attributed to the accurate description down to molecular scale by the generalized Navier boundary condition in our continuum model. Numerical results are also presented for the relaxational dynamics of fluid-fluid interface, in agreement with a theoretical analysis based on the Onsager principle of minimum energy dissipation. © 2010 Global-Science Press.

  11. Occupational allergic contact dermatitis caused by sterile non-latex protective gloves: clinical investigation and chemical analyses.

    Science.gov (United States)

    Pontén, Ann; Hamnerius, Nils; Bruze, Magnus; Hansson, Christer; Persson, Christina; Svedman, Cecilia; Thörneby Andersson, Kirsten; Bergendorff, Ola

    2013-02-01

    An increased frequency of occupational contact hand dermatitis among surgical operating theatre personnel has been noticed. To evaluate patients with occupational contact dermatitis caused by their rubber gloves, and to describe a method for analysing the content of the allergens in the gloves. Patch tests were performed with the baseline series, a rubber chemical series, and the patients' own gloves. A method for analysing 1,3-diphenylguanidine (DPG) and cetylpyridinium chloride in the gloves was developed. Contact allergy to thiuram mix was found in 8 of 16 patients, whereas 12 of 16 patients reacted to DPG. In 7 of 8 patients, contact allergy to cetylpyridinium chloride was found. In the patients' gloves, cetylpyridinium chloride and DPG were detected at higher concentrations on the inside of the gloves than on the outside. Most patients had worked for decades in their present occupations, but their hand dermatitis had only been present for months. Contact allergy to DPG in gloves has been disputed, but, in this study, we were able to confirm the presence of DPG and cetylpyridinium chloride in the causative gloves by using a modified method for the analysis. The presence of these chemicals in gloves caused an increase in occupational contact dermatitis in surgical operating theatre personnel. © 2012 John Wiley & Sons A/S.

  12. Contact dermatitis caused by preservatives.

    Science.gov (United States)

    Yim, Elizabeth; Baquerizo Nole, Katherine L; Tosti, Antonella

    2014-01-01

    Preservatives are biocidal chemicals added to food, cosmetics, and industrial products to prevent the growth of microorganisms. They are usually nontoxic and inexpensive and have a long shelf life. Unfortunately, they commonly cause contact dermatitis. This article reviews the most important classes of preservatives physicians are most likely to encounter in their daily practice, specifically isothiazolinones, formaldehyde and formaldehyde-releasers, iodopropynyl butylcarbamate, methyldibromoglutaronitrile, and parabens. For each preservative mentioned, the prevalence of sensitization, clinical presentation of contact dermatitis, patch testing concentrations, cross reactions, and related legislation will be discussed. Mandatory labeling of preservatives is required in some countries, but not required in others. Until policies are made, physicians and patients must be proactive in identifying potential sensitizers and removing their use. We hope that this article will serve as a guide for policy makers in creating legislation and future regulations on the use and concentration of certain preservatives in cosmetics and industrial products.

  13. Nickel contact sensitivity in the guinea pig. An efficient open application test method

    DEFF Research Database (Denmark)

    Nielsen, G D; Rohold, A E; Andersen, Klaus Ejner

    1992-01-01

    Nickel contact sensitivity was successfully induced in guinea pigs using an open epicutaneous application method. Immediately after pretreatment with 1% aqueous sodium lauryl sulfate, upper back skin was treated daily for 4 weeks with 0.3%-3% nickel sulfate in either a 1% lanolin cream (Vaseline, p...

  14. Footwear contact dermatitis from dimethyl fumarate.

    Science.gov (United States)

    Švecová, Danka; Šimaljakova, Maria; Doležalová, Anna

    2013-07-01

    Dimethyl fumarate (DMF) is an effective inhibitor of mold growth. In very low concentrations, DMF is a potent sensitizer that can cause severe allergic contact dermatitis (ACD). It has been identified as the agent responsible for furniture contact dermatitis in Europe. The aim of this study was to evaluate patients in Slovakia with footwear ACD associated with DMF, with regard to clinical manifestations, patch test results, and results of chemical analysis of their footwear. Nine patients with suspected footwear contact dermatitis underwent patch testing with the following allergens: samples of their own footwear, commercial DMF, the European baseline, shoe screening, textile and leather dye screening, and industrial biocides series. The results were recorded according to international guidelines. The content of DMF in footwear and anti-mold sachets was analyzed using gas chromatography and mass spectrometry. Acute ACD was observed in nine Caucasian female patients. All patients developed delayed sensitization, as demonstrated by positive patch testing using textile footwear lining. Seven patients were patch tested with 0.1% DMF, and all seven were positive. Chemical analysis of available footwear showed that DMF was present in very high concentrations (25-80 mg/Kg). Dimethyl fumarate is a new footwear allergen and was responsible for severe ACD in our patients. To avoid an increase in the number of cases, the already approved European preventive measures should be accepted and commonly employed. © 2013 The International Society of Dermatology.

  15. Sensitivity of animals to chemical compounds links to metabolic rate.

    NARCIS (Netherlands)

    Baas, J.; Kooijman, S.A.L.M.

    2015-01-01

    Ecotoxicological studies have shown considerable variation in species sensitivity for chemical compounds, but general patterns in sensitivity are still not known. A better understanding of this sensitivity is important in the context of environmental risk assessment but also in a more general

  16. The possible role of contact sensitization to fragrances and preservatives in poikiloderma of civatte.

    Science.gov (United States)

    Khunkhet, Saranya; Wattanakrai, Penpun

    2014-09-01

    Numerous mechanisms have been postulated to play an important role in the pathogenesis of poikiloderma of Civatte (PC), including chronic exposure to ultraviolet radiation, menopause-related hormonal changes, contact hypersensitivity and genetic predisposition. Herein, we report a case of contact sensitization to fragrances and commonly used preservatives, methylchloroisothiazolinone and methylisothiazolinone, also widely known as Kathon CG, in a post-menopausal woman with PC, who denied excessive sun exposure and a family history. After abstaining from the use of her personal care products containing the documented allergens, not only the itching and burning symptoms, but also the cutaneous changes appeared to improve partially. This report underlines the possible influence of contact hypersensitivity in the pathogenesis of PC.

  17. The Possible Role of Contact Sensitization to Fragrances and Preservatives in Poikiloderma of Civatte

    Directory of Open Access Journals (Sweden)

    Saranya Khunkhet

    2014-11-01

    Full Text Available Numerous mechanisms have been postulated to play an important role in the pathogenesis of poikiloderma of Civatte (PC, including chronic exposure to ultraviolet radiation, menopause-related hormonal changes, contact hypersensitivity and genetic predisposition. Herein, we report a case of contact sensitization to fragrances and commonly used preservatives, methylchloroisothiazolinone and methylisothiazolinone, also widely known as Kathon CG, in a post-menopausal woman with PC, who denied excessive sun exposure and a family history. After abstaining from the use of her personal care products containing the documented allergens, not only the itching and burning symptoms, but also the cutaneous changes appeared to improve partially. This report underlines the possible influence of contact hypersensitivity in the pathogenesis of PC.

  18. Exploring the sensitivity of the zone of inhibition test for leachable biocides from paper and board food contact materials, and improvements thereof.

    Science.gov (United States)

    Castle, L; Kelly, J; Jickells, S M; Johns, S M; Mountfort, K A

    2012-01-01

    The zone of inhibition method to test the release of biocides from paper and board food contact materials was evaluated. The method tests the paper by placing a small specimen directly onto culture plates of Bacillus subtilis and Aspergillus niger. The principle is that any extractable biocide will diffuse from the paper into the surrounding nutrient medium and so inhibit growth of the microorganism in the vicinity. The test was found to have insufficient sensitivity for assuring food safety, where detection limits for migration at or below the mg l(-1) (parts per million) level are needed. Also, the test does not mimic the actual or foreseeable conditions of use since most paper/board materials are not intended for direct contact with an aqueous medium for up to 3 days at 30°C (B. subtilis) or 25°C (A. niger), which are the incubation conditions used. The sensitivity of the test was increased approximately 100-fold by preparing a concentrated extract of the paper to be tested and applying this extract to the assay via a blank paper carrier. This was done using methanol as a good solvent for most biocides, as a proof of principle. Other solvents or food simulants could be used to mimic the conditions of use intended for the particular paper/board samples under examination, e.g. contact with dry, fatty, aqueous or acidic foods, hot or cold. Twenty-four plain (unconverted) paper and board samples and 100 food packaging samples were evaluated using the modified procedure. The results revealed that the method has been developed to the stage where background cytotoxic action of normal paper constituents gives a weak response. Unlike the original method, therefore, the modified method with its improved sensitivity and the facility to link with the intended food contact conditions may be considered a suitable bioassay screening test to complement chemical analysis of paper/board for composition and migration.

  19. Allergic contact dermatitis from resin hardeners during the manufacture of thermosetting coating paints.

    Science.gov (United States)

    Foulds, I S; Koh, D

    1992-02-01

    5 production operators from 2 factories manufacturing thermosetting coating paint developed work-related skin disorders within 12 months of the introduction of a new powdered paint product. All 5 workers were found to have allergic contact dermatitis from 2 epoxy resin hardeners, both of which were commercial preparations of triglycidyl isocyanurate (TGIC). 2 of the workers had concomitant sensitization to epoxy resin in the standard series and several of the epoxy resin preparations at the workplace. TGIC has been reported as a contact sensitizer both in persons producing the chemical and among end-users of TGIC-containing products. These 5 reported cases document allergic contact dermatitis from commercial TGIC among exposed workers during an intermediate process of powdered paint manufacture. The possibility of substituting this epoxy resin hardener with less sensitizing alternatives should be explored.

  20. Hand eczema: Correlation of morphologic patterns, atopy, contact sensitization and disease severity

    Directory of Open Access Journals (Sweden)

    Sanjeev Handa

    2012-01-01

    Full Text Available Background: Hand eczema is a common distressing condition aggravated by a number of endogenous and exogenous factors. Various morphological forms of hand eczema have been described, but categorization into one of them is not always possible. Aims: To study the morphological patterns of hand eczema, relationship of atopy with hand eczema, and the implications of contact sensitization with respect to severity and diagnosis of hand eczema. Methods: Hundred consecutive patients of hand eczema attending the contact dermatitis clinic of the institute were recruited over a two year period from 2004-05. Objective assessment was done using hand eczema severity index (HECSI and all the patients were patch tested using Indian standard series. Results: Unspecified type of hand eczema with no definite morphologic picture was seen in 62% followed by pompholyx in 14%. Hand eczema severity was not found to be statistically associated with age, sex, and atopic status of the patient. Positive patch test to one or more allergen was present in 65% of patients. The most common allergens were potassium dichromate (25%, fragrance mix (16%, nickel sulphate (14%, and PPD (13%. There was no significant correlation between patch test positivity and hand eczema severity or atopic status of the patient. Among the morphological patterns pompholyx was strongly associated with an atopic status (P=0.004. Conclusions: Hand eczema was seen twice more commonly in men. Atopic and non-atopic patients of hand eczema had no difference in the severity of disease. Contact sensitivity to different allergens did not correlate with increased eczema severity.

  1. 125I-Fibrin deposition in contact sensitivity reactions in the mouse. Sensitivity of the assay for quantitating reactions after active or passive sensitization

    International Nuclear Information System (INIS)

    Mekori, Y.A.; Dvorak, H.F.; Galli, S.J.

    1986-01-01

    The clotting associated with delayed hypersensitivity (DH) responses in the mouse by sensitizing the animals to the contactant oxazolone (Ox), and then administering 125 I-guinea pig fibrinogen i.v. 10 to 30 min before antigen challenge 5 days later. Early (4 to 8 hr) contact sensitivity (CS) responses in immunized mice were barely detectable by three conventional measures of CS, but the total 125 I-cpm in ears challenged with hapten was 3.6 to 4.5 x that in control ears challenged with vehicle alone; moreover, the amount of urea-insoluble cpm (cross-linked 125 I-fibrin-associated cpm) in the reactions to Ox was 6.5-fold to 8.2-fold that present in the control reactions. In 24 hr reactions that were near peak intensity by measurements of ear swelling, ear weight ratios, and ratios of 125 I-5-iodo-2-deoxyuridine-labeled leukocyte infiltration, the cpm in antigen-challenged ears exceeded that in control ears by 13-fold to 53-fold. In addition, antigen-challenged ears contained 27 to 300 x the urea-insoluble cpm present in control ears. 125 I-Fibrin deposition was not a specific characteristic of CS reactions, because a small amount of urea-insoluble reactivity was also detected in some reactions to Ox in native mice. Nevertheless, the assay was exquisitely sensitive and readily detected quantitative differences between the immunologically specific and nonspecific reactions at very early intervals after challenge or with suboptimal doses of antigen

  2. Chemical control of electrical contact to sp² carbon atoms.

    Science.gov (United States)

    Frederiksen, Thomas; Foti, Giuseppe; Scheurer, Fabrice; Speisser, Virginie; Schull, Guillaume

    2014-04-16

    Carbon-based nanostructures are attracting tremendous interest as components in ultrafast electronics and optoelectronics. The electrical interfaces to these structures play a crucial role for the electron transport, but the lack of control at the atomic scale can hamper device functionality and integration into operating circuitry. Here we study a prototype carbon-based molecular junction consisting of a single C60 molecule and probe how the electric current through the junction depends on the chemical nature of the foremost electrode atom in contact with the molecule. We find that the efficiency of charge injection to a C60 molecule varies substantially for the considered metallic species, and demonstrate that the relative strength of the metal-C bond can be extracted from our transport measurements. Our study further suggests that a single-C60 junction is a basic model to explore the properties of electrical contacts to meso- and macroscopic sp(2) carbon structures.

  3. Chemical control of electrical contact to sp2 carbon atoms

    Science.gov (United States)

    Frederiksen, Thomas; Foti, Giuseppe; Scheurer, Fabrice; Speisser, Virginie; Schull, Guillaume

    2014-04-01

    Carbon-based nanostructures are attracting tremendous interest as components in ultrafast electronics and optoelectronics. The electrical interfaces to these structures play a crucial role for the electron transport, but the lack of control at the atomic scale can hamper device functionality and integration into operating circuitry. Here we study a prototype carbon-based molecular junction consisting of a single C60 molecule and probe how the electric current through the junction depends on the chemical nature of the foremost electrode atom in contact with the molecule. We find that the efficiency of charge injection to a C60 molecule varies substantially for the considered metallic species, and demonstrate that the relative strength of the metal-C bond can be extracted from our transport measurements. Our study further suggests that a single-C60 junction is a basic model to explore the properties of electrical contacts to meso- and macroscopic sp2 carbon structures.

  4. Wet-Chemical Preparation of Silicon Tunnel Oxides for Transparent Passivated Contacts in Crystalline Silicon Solar Cells.

    Science.gov (United States)

    Köhler, Malte; Pomaska, Manuel; Lentz, Florian; Finger, Friedhelm; Rau, Uwe; Ding, Kaining

    2018-05-02

    Transparent passivated contacts (TPCs) using a wide band gap microcrystalline silicon carbide (μc-SiC:H(n)), silicon tunnel oxide (SiO 2 ) stack are an alternative to amorphous silicon-based contacts for the front side of silicon heterojunction solar cells. In a systematic study of the μc-SiC:H(n)/SiO 2 /c-Si contact, we investigated selected wet-chemical oxidation methods for the formation of ultrathin SiO 2 , in order to passivate the silicon surface while ensuring a low contact resistivity. By tuning the SiO 2 properties, implied open-circuit voltages of 714 mV and contact resistivities of 32 mΩ cm 2 were achieved using μc-SiC:H(n)/SiO 2 /c-Si as transparent passivated contacts.

  5. Non-allergic cutaneous reactions in airborne chemical sensitivity--a population based study

    DEFF Research Database (Denmark)

    Berg, Nikolaj Drimer; Linneberg, Allan; Thyssen, Jacob Pontoppidan

    2011-01-01

    the relationship between cutaneous reactions from patch testing and self-reported severity of chemical sensitivity to common airborne chemicals. A total of 3460 individuals participating in a general health examination, Health 2006, were patch tested with allergens from the European standard series and screened...... most severe groups of self-reported sensitivity to airborne chemicals. When adjusting for confounding, associations were weakened, and only non-allergic cutaneous reactions were significantly associated with individuals most severely affected by inhalation of airborne chemicals (odds ratio = 2.5, p = 0...

  6. Effects of symbiotic bacteria on chemical sensitivity of Daphnia magna.

    Science.gov (United States)

    Manakul, Patcharaporn; Peerakietkhajorn, Saranya; Matsuura, Tomoaki; Kato, Yasuhiko; Watanabe, Hajime

    2017-07-01

    The crustacean zooplankton Daphnia magna has been widely used for chemical toxicity tests. Although abiotic factors have been well documented in ecotoxicological test protocols, biotic factors that may affect the sensitivity to chemical compounds remain limited. Recently, we identified symbiotic bacteria that are critical for the growth and reproduction of D. magna. The presence of symbiotic bacteria on Daphnia raised the question as to whether these bacteria have a positive or negative effect on toxicity tests. In order to evaluate the effects of symbiotic bacteria on toxicity tests, bacteria-free Daphnia were prepared, and their chemical sensitivities were compared with that of Daphnia with symbiotic bacteria based on an acute immobilization test. The Daphnia with symbiotic bacteria showed higher chemical resistance to nonylphenol, fenoxycarb, and pentachlorophenol than bacteria-free Daphnia. These results suggested potential roles of symbiotic bacteria in the chemical resistance of its host Daphnia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Dynamic contact angle cycling homogenizes heterogeneous surfaces.

    Science.gov (United States)

    Belibel, R; Barbaud, C; Mora, L

    2016-12-01

    In order to reduce restenosis, the necessity to develop the appropriate coating material of metallic stent is a challenge for biomedicine and scientific research over the past decade. Therefore, biodegradable copolymers of poly((R,S)-3,3 dimethylmalic acid) (PDMMLA) were prepared in order to develop a new coating exhibiting different custom groups in its side chain and being able to carry a drug. This material will be in direct contact with cells and blood. It consists of carboxylic acid and hexylic groups used for hydrophilic and hydrophobic character, respectively. The study of this material wettability and dynamic surface properties is of importance due to the influence of the chemistry and the potential motility of these chemical groups on cell adhesion and polymer kinetic hydrolysis. Cassie theory was used for the theoretical correction of contact angles of these chemical heterogeneous surfaces coatings. Dynamic Surface Analysis was used as practical homogenizer of chemical heterogeneous surfaces by cycling during many cycles in water. In this work, we confirmed that, unlike receding contact angle, advancing contact angle is influenced by the difference of only 10% of acidic groups (%A) in side-chain of polymers. It linearly decreases with increasing acidity percentage. Hysteresis (H) is also a sensitive parameter which is discussed in this paper. Finally, we conclude that cycling provides real information, thus avoiding theoretical Cassie correction. H(10)is the most sensible parameter to %A. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. CHEMICAL VAPOUR DEPOSITION FROM A RADIATION-SENSITIVE PRECURSOR

    DEFF Research Database (Denmark)

    2017-01-01

    The present invention relates in one aspect to a method of depositing a thin film on a substrate by chemical vapour deposition (CVD) from a radiation-sensitive precursor substance. The method comprises the steps of: (i) placing the substrate in a reaction chamber of a CVD system; (ii) heating...... heating pulse followed by an idle period; (iii) during at least one of the idle periods, providing a pressure pulse of precursor substance inside the reaction chamber by feeding at least one precursor substance to the reaction chamber so as to establish a reaction partial pressure for thin film deposition...... is formed. According to a further aspect, the invention relates to a chemical vapour deposition (CVD) system for depositing a thin film onto a substrate using precursor substances containing at least one radiation sensitive species....

  9. An elevated pro-inflammatory cytokine profile in multiple chemical sensitivity

    DEFF Research Database (Denmark)

    Dantoft, Thomas Meinertz; Elberling, J.; Brix, Susanne

    2014-01-01

    BackgroundMultiple chemical sensitivity (MCS) is a medically unexplained condition characterized by reports of recurrent unspecific symptoms attributed to exposure to low levels of common volatile chemicals. The etiology of MCS is poorly understood, but dysregulation of the immune system has been...

  10. Transient receptor potential ankyrin 1 activation enhances hapten sensitization in a T-helper type 2-driven fluorescein isothiocyanate-induced contact hypersensitivity mouse model

    International Nuclear Information System (INIS)

    Shiba, Takahiro; Tamai, Takuma; Sahara, Yurina; Kurohane, Kohta; Watanabe, Tatsuo; Imai, Yasuyuki

    2012-01-01

    Some chemicals contribute to the development of allergies by increasing the immunogenicity of other allergens. We have demonstrated that several phthalate esters, including dibutyl phthalate (DBP), enhance skin sensitization to fluorescein isothiocyanate (FITC) in a mouse contact hypersensitivity model, in which the T-helper type 2 (Th2) response is essential. On the other hand, some phthalate esters were found to activate transient receptor potential ankyrin 1 (TRPA1) cation channels on sensory neurons. We then found a positive correlation between the enhancing effects of several types of phthalate esters on skin sensitization to FITC and their ability to activate TRPA1. Here we examined the involvement of TRPA1 in sensitization to FITC by using TRPA1 agonists other than phthalate esters. During skin sensitization to FITC, the TRPA1 agonists (menthol, carvacrol, cinnamaldehyde and DBP) augmented the ear-swelling response as well as trafficking of FITC-presenting dendritic cells to draining lymph nodes. We confirmed that these TRPA1 agonists induced calcium influx into TRPA1-expressing Chinese hamster ovary (CHO) cells. We also found that TRPA1 antagonist HC-030031 inhibited DBP-induced calcium influx into TRPA1-expressing CHO cells. After pretreatment with this antagonist upon skin sensitization to FITC, the enhancing effect of DBP on sensitization was suppressed. These results suggest that TRPA1 activation will become a useful marker to find chemicals that facilitate sensitization in combination with other immunogenic haptens. -- Highlights: ► Role of TRPA1 activation was revealed in a mouse model of skin sensitization to FITC. ► TRPA1 agonists enhanced skin sensitization as well as dendritic cell trafficking. ► Dibutyl phthalate (DBP) has been shown to enhance skin sensitization to FITC. ► TRPA1 activation by DBP was inhibited by a selective antagonist, HC-030031. ► HC-030031 inhibited the enhancing effect of DBP on skin sensitization to FITC.

  11. Transient receptor potential ankyrin 1 activation enhances hapten sensitization in a T-helper type 2-driven fluorescein isothiocyanate-induced contact hypersensitivity mouse model

    Energy Technology Data Exchange (ETDEWEB)

    Shiba, Takahiro; Tamai, Takuma; Sahara, Yurina; Kurohane, Kohta [Laboratory of Microbiology and Immunology, School of Pharmaceutical Sciences, University of Shizuoka, 52‐1 Yada, Suruga-ku, Shizuoka City, Shizuoka 422‐8526 (Japan); Watanabe, Tatsuo [Laboratory of Food Chemistry, School of Food and Nutritional Sciences, University of Shizuoka, 52‐1 Yada, Suruga-ku, Shizuoka City, Shizuoka 422‐8526 (Japan); Imai, Yasuyuki, E-mail: imai@u-shizuoka-ken.ac.jp [Laboratory of Microbiology and Immunology, School of Pharmaceutical Sciences, University of Shizuoka, 52‐1 Yada, Suruga-ku, Shizuoka City, Shizuoka 422‐8526 (Japan)

    2012-11-01

    Some chemicals contribute to the development of allergies by increasing the immunogenicity of other allergens. We have demonstrated that several phthalate esters, including dibutyl phthalate (DBP), enhance skin sensitization to fluorescein isothiocyanate (FITC) in a mouse contact hypersensitivity model, in which the T-helper type 2 (Th2) response is essential. On the other hand, some phthalate esters were found to activate transient receptor potential ankyrin 1 (TRPA1) cation channels on sensory neurons. We then found a positive correlation between the enhancing effects of several types of phthalate esters on skin sensitization to FITC and their ability to activate TRPA1. Here we examined the involvement of TRPA1 in sensitization to FITC by using TRPA1 agonists other than phthalate esters. During skin sensitization to FITC, the TRPA1 agonists (menthol, carvacrol, cinnamaldehyde and DBP) augmented the ear-swelling response as well as trafficking of FITC-presenting dendritic cells to draining lymph nodes. We confirmed that these TRPA1 agonists induced calcium influx into TRPA1-expressing Chinese hamster ovary (CHO) cells. We also found that TRPA1 antagonist HC-030031 inhibited DBP-induced calcium influx into TRPA1-expressing CHO cells. After pretreatment with this antagonist upon skin sensitization to FITC, the enhancing effect of DBP on sensitization was suppressed. These results suggest that TRPA1 activation will become a useful marker to find chemicals that facilitate sensitization in combination with other immunogenic haptens. -- Highlights: ► Role of TRPA1 activation was revealed in a mouse model of skin sensitization to FITC. ► TRPA1 agonists enhanced skin sensitization as well as dendritic cell trafficking. ► Dibutyl phthalate (DBP) has been shown to enhance skin sensitization to FITC. ► TRPA1 activation by DBP was inhibited by a selective antagonist, HC-030031. ► HC-030031 inhibited the enhancing effect of DBP on skin sensitization to FITC.

  12. Chemical and electrical characteristics of annealed Ni/Au and Ni/Ir/Au contacts on AlGaN

    Energy Technology Data Exchange (ETDEWEB)

    Ngoepe, P.N.M., E-mail: phuti.ngoepe@up.ac.za [Department of Physics, University of Pretoria, Private Bag X20, Hatfield 0028 (South Africa); Meyer, W.E.; Auret, F.D.; Omotoso, E.; Diale, M. [Department of Physics, University of Pretoria, Private Bag X20, Hatfield 0028 (South Africa); Swart, H.C.; Duvenhage, M.M.; Coetsee, E. [Department of Physics, University of the Free State, P.O. Box 339, Bloemfontein 9300 (South Africa)

    2016-01-01

    The evolution of Ni/Au and Ni/Ir/Au metal contacts deposited on AlGaN was investigated at different annealing temperatures. The samples were studied with electrical and chemical composition techniques. I–V characteristics of the Schottky diodes were optimum after 500 and 600 °C annealing for Ni/Au and Ni/Ir/Au based diodes, respectively. The depth profiles of the contacts were measured by x-ray photoelectron spectroscopy and time of flight secondary ion mass spectroscopy. These chemical composition techniques were used to examine the evolution of the metal contacts in order to verify the influence the metals have on the electrical properties of the diodes. The insertion of Ir as a diffusion barrier between Ni and Au effected the electrical properties, improving the stability of the contacts at high temperatures. Gold diffused into the AlGaN film, degrading the electrical properties of the Ni/Au diode. At 500 °C, the insertion of Ir, however, prevented the in-diffusion of Au into the AlGaN substrate.

  13. Allergic Contact Dermatitis

    Directory of Open Access Journals (Sweden)

    Meltem Önder

    2009-03-01

    Full Text Available Allergic contact dermatitis is the delayed type hypersensitivity reaction to exogenous agents. Allergic contact dermatitis may clinically present acutely after allergen exposure and initial sensitization in a previously sensitized individual. Acute phase is characterized by erythematous, scaly plaques. In severe cases vesiculation and bullae in exposed areas are very characteristic. Repeated or continuous exposure of sensitized individual with allergen result in chronic dermatitis. Lichenification, erythematous plaques, hyperkeratosis and fissuring may develop in chronic patients. Allergic contact dermatitis is very common dermatologic problem in dermatology daily practice. A diagnosis of contact dermatitis requires the careful consideration of patient history, physical examination and patch testing. The knowledge of the clinical features of the skin reactions to various contactans is important to make a correct diagnosis of contact dermatitis. It can be seen in every age, in children textile product, accessories and touch products are common allergens, while in adults allergic contact dermatitis may be related with topical medicaments. The contact pattern of contact dermatitis depends on fashion and local traditions as well. The localization of allergic reaction should be evaluated and patients’ occupation and hobbies should be asked. The purpose of this review is to introduce to our collaques up dated allergic contact dermatitis literatures both in Turkey and in the World.

  14. High-throughput dietary exposure predictions for chemical migrants from food contact substances for use in chemical prioritization.

    Science.gov (United States)

    Biryol, Derya; Nicolas, Chantel I; Wambaugh, John; Phillips, Katherine; Isaacs, Kristin

    2017-11-01

    Under the ExpoCast program, United States Environmental Protection Agency (EPA) researchers have developed a high-throughput (HT) framework for estimating aggregate exposures to chemicals from multiple pathways to support rapid prioritization of chemicals. Here, we present methods to estimate HT exposures to chemicals migrating into food from food contact substances (FCS). These methods consisted of combining an empirical model of chemical migration with estimates of daily population food intakes derived from food diaries from the National Health and Nutrition Examination Survey (NHANES). A linear regression model for migration at equilibrium was developed by fitting available migration measurements as a function of temperature, food type (i.e., fatty, aqueous, acidic, alcoholic), initial chemical concentration in the FCS (C 0 ) and chemical properties. The most predictive variables in the resulting model were C 0 , molecular weight, log K ow , and food type (R 2 =0.71, pchemicals identified via publicly-available data sources as being present in polymer FCSs were predicted for 12 food groups (combinations of 3 storage temperatures and food type). The model was parameterized with screening-level estimates of C 0 based on the functional role of chemicals in FCS. By combining these concentrations with daily intakes for food groups derived from NHANES, population ingestion exposures of chemical in mg/kg-bodyweight/day (mg/kg-BW/day) were estimated. Calibrated aggregate exposures were estimated for 1931 chemicals by fitting HT FCS and consumer product exposures to exposures inferred from NHANES biomonitoring (R 2 =0.61, pchemicals), they can provide critical refinement to aggregate exposure predictions used in risk-based chemical priority-setting. Published by Elsevier Ltd.

  15. Sickness-related dysfunction in persons with self-reported multiple chemical sensitivity at four levels of severity.

    Science.gov (United States)

    Gibson, Pamela Reed; Vogel, Valerie M

    2009-01-01

    To examine quality of life outcome for persons who self-report chemical sensitivity, often referred to as multiple chemical sensitivity. Multiple chemical sensitivity is poorly understood with few providers specialising in its treatment. This lack of treatment and the ubiquity of chemicals engender severe life impacts such as job loss, financial loss, social isolation and even homelessness for persons who experience these sensitivities. Survey. We examined chemical incitants, symptoms and sickness-related behavioural dysfunction as measured by the Sickness Impact Profile in 254 persons self-identified with multiple chemical sensitivity. Chemicals rated as causing the most symptomatology in respondents were pesticide, formaldehyde, fresh paint, new carpet, diesel exhaust, perfume and air fresheners. The five highest rated symptoms in this sample were tiredness/lethargy, difficulty concentrating, muscle aches, memory difficulties and long-term fatigue. Overall mean Sickness Impact Profile score was 25.25%, showing serious impairment, with the most serious dysfunction in the categories of work (55.36%), alertness behaviour (53.45%) and recreation and pastimes (45.20%). Multiple chemical sensitivity is an important health care issue because it often includes serious dysfunction, is poorly understood by providers and poses extensive financial and treatment obstacles for those who experience it. Persons with multiple chemical sensitivity seek medical treatment in a variety of contexts and informed providers can both avoid iatrogenic harm due to medical exposures and provide any possible treatment for the chemical sensitivities. Understanding the impact of the health condition is crucial to communicate with and treat persons who experience the sensitivities.

  16. Clinical update on contact allergy

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Johansen, Jeanne Duus; Orton, David I

    2005-01-01

    PURPOSE OF REVIEW: The aim of this article is to review recent findings in contact allergy, regarding clinical research. RECENT FINDINGS: The biocide methyldibromo glutaronitrile was identified to be an important sensitizer. Subsequently, it was banned from leave-on cosmetics in the European Union....... Another group of important allergens that have been studied extensively included the fragrances oak moss absolute, isoeugenol, hydroxyisohexyl 3-cyclohexene carboxaldehyde and farnesol. A new fragrance mix II has been developed for standard testing, which includes the two latter compounds. Dose response...... a classification of newly introduced chemicals; increasingly, the local lymph node assay is supplementing and potentially replacing the guinea pig maximization test. Recent advances in occupational contact allergy include, for example, some attempts to improve diagnostics for epoxy resin and other plastic, glue...

  17. Local lymph node assay (LLNA) for detection of sensitization capacity of chemicals.

    Science.gov (United States)

    Gerberick, G Frank; Ryan, Cindy A; Dearman, Rebecca J; Kimber, Ian

    2007-01-01

    The local lymph node assay (LLNA) is a murine model developed to evaluate the skin sensitization potential of chemicals. The LLNA is an alternative approach to traditional guinea pig methods and in comparison provides important animal welfare benefits. The assay relies on measurement of events induced during the induction phase of skin sensitization, specifically lymphocyte proliferation in the draining lymph nodes which is a hallmark of a skin sensitization response. Since its introduction the LLNA has been the subject of extensive evaluation on a national and international scale, and has been successfully validated and incorporated worldwide into regulatory guidelines. Experience gained in recent years has demonstrated that adherence to published procedures and guidelines for the LLNA (e.g., with respect to dose and vehicle selection) is critical for the successful conduct and eventual interpretation of the data. In addition to providing a robust method for skin sensitization hazard identification, the LLNA has proven very useful in assessing the skin sensitizing potency of test chemicals, and this has provided invaluable information to risk assessors. The primary method to make comparisons of the relative potency of chemical sensitizers is to use linear interpolation to estimate the concentration of chemical required to induce a stimulation index of three relative to concurrent vehicle-treated controls (EC3). In certain situations where there are available less than optimal dose response data a log-linear extrapolation method can be used to estimate an EC3 value which can reduce significantly the need for repeat testing of chemicals. The LLNA, when conducted according to published guidelines, provides a robust method for skin sensitization testing that not only provides reliable hazard identification information but also data necessary for effective risk assessment and risk management.

  18. An effect-directed strategy for characterizing emerging chemicals in food contact materials made from paper and board

    DEFF Research Database (Denmark)

    Rosenmai, Anna Kjerstine; Bengtström, Linda; Taxvig, Camilla

    2017-01-01

    Food contact materials (FCM) are any type of item intended to come into contact with foods and thus represent a potential source for human exposure to chemicals. Regarding FCMs made of paper and board, information pertaining to their chemical constituents and the potential impacts on human health...... FCMs exhibited activities in at least one assay. As proof-of-principle, FCM samples obtained from a sandwich wrapper and a pizza box were carried through a complete step-by-step multi-tiered approach. The pizza box exhibited ER activity, likely caused by the presence of bisphenol A, dibutyl phthalate......, and benzylbutyl phthalate. The sandwich wrapper exhibited AR antagonism, likely caused by abietic acid and dehydroabietic acid. Migration studies confirmed that the active chemicals can transfer from FCMs to food simulants. In conclusion, we report an effect-directed strategy that can identify hazards posed...

  19. Development and utilization of an ex vivo bromodeoxyuridine local lymph node assay protocol for assessing potential chemical sensitizers.

    Science.gov (United States)

    Williams, W C; Copeland, C; Boykin, E; Quell, S J; Lehmann, D M

    2015-01-01

    The murine local lymph node assay (LLNA) is widely used to identify chemicals that may cause allergic contact dermatitis. Exposure to a dermal sensitizer results in proliferation of local lymph node T cells, which has traditionally been measured by in vivo incorporation of [(3) H]methyl thymidine. A more recent non-isotopic variation of the assay utilizes bromodeoxyuridine (BrdU) incorporation in vivo. To further improve the utility of this assay, we developed an ex vivo BrdU labeling procedure eliminating the need for in vivo injections. The results of this assay correctly identified a strong sensitizer (i.e., trimellitic anhydride) as well as weak/moderate sensitizers (i.e., eugenol, cinnamaldehyde and hexylcinnaminic aldehyde). As anticipated, neither non-sensitizers isopropanol and lactic acid nor the false negative chemical nickel II sulfate hexahydrate induced a positive threshold response in the assay. The results of this assay are in close agreement with those of the in vivo LLNA:BrdU-enzyme-linked immunosorbent assay labeling procedure. We also used the ex vivo BrdU LLNA procedure to evaluate ammonium hexachloroplatinate, ammonium tetrachloroplatinate and cis-diamminedichloroplatinum(II) and the assay correctly identified them as sensitizers based on the calculation of EC2 values. We conclude that this ex vivo BrdU labeling method offers predictive capacity comparable to previously established LLNA protocols while eliminating animal injections and the use of radioisotope. Published 2014. This article is a U.S. Government work and is in the public domain in the USA. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  20. Friction behavior of glass and metals in contact with glass in various environments

    Science.gov (United States)

    Buckley, D. H.

    1973-01-01

    Sliding friction experiments have been conducted for heat-resistant glass and metals in contact with glass. These experiments were conducted in various environments including vacuum, moist air, dry air, octane, and stearic acid in hexadecane. Glass exhibited a higher friction force in moist air than it did in vacuum when in sliding contact with itself. The metals, aluminum, iron, and gold, all exhibited the same friction coefficient when sliding on glass in vacuum as glass sliding on glass. Gold-to-glass contacts were extremely sensitive to the environment despite the relative chemical inertness of gold.

  1. Development of High Temperature/High Sensitivity Novel Chemical Resistive Sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Chunrui [Univ. of Texas, San Antonio, TX (United States); Enriquez, Erik [Univ. of Texas, San Antonio, TX (United States); Wang, Haibing [Univ. of Texas, San Antonio, TX (United States); Xu, Xing [Univ. of Texas, San Antonio, TX (United States); Bao, Shangyong [Univ. of Texas, San Antonio, TX (United States); Collins, Gregory [Univ. of Texas, San Antonio, TX (United States)

    2013-08-13

    The research has been focused to design, fabricate, and develop high temperature/high sensitivity novel multifunctional chemical sensors for the selective detection of fossil energy gases used in power and fuel systems. By systematically studying the physical properties of the LnBaCo2O5+d (LBCO) [Ln=Pr or La] thin-films, a new concept chemical sensor based high temperature chemical resistant change has been developed for the application for the next generation highly efficient and near zero emission power generation technologies. We also discovered that the superfast chemical dynamic behavior and an ultrafast surface exchange kinetics in the highly epitaxial LBCO thin films. Furthermore, our research indicates that hydrogen can superfast diffuse in the ordered oxygen vacancy structures in the highly epitaxial LBCO thin films, which suggest that the LBCO thin film not only can be an excellent candidate for the fabrication of high temperature ultra sensitive chemical sensors and control systems for power and fuel monitoring systems, but also can be an excellent candidate for the low temperature solid oxide fuel cell anode and cathode materials.

  2. Sensitive chemical neutron dosimetry using silver colloids

    International Nuclear Information System (INIS)

    Brede, O.; Boes, J.; Hoesselbarth, B.

    1982-01-01

    The radiation-induced formation of silver colloid was checked for its use as a sensitive dosimeter for neutron irradiation. For non-monoenergetic pulsed neutron irradiation in the Dubna IBR-30 reactor, the colloid dosimeter was found to be suitable to indicate the chemical neutron effect, i.e., to determine the sum concentration of the primary particles of water radiolysis: esub(aq)sup(-), OH and H. (author)

  3. NCTC 2544 and IL-18 production: a tool for the identification of contact allergens.

    Science.gov (United States)

    Corsini, Emanuela; Galbiati, Valentina; Mitjans, Montserrat; Galli, Corrado L; Marinovich, Marina

    2013-04-01

    Progress in understanding the mechanisms of skin sensitization, provides us with the opportunity to develop in vitro tests as an alternative to in vivo sensitization testing. Keratinocytes play a key role in all phases of skin sensitization. We have recently identified interleukin-18 (IL-18) production in keratinocyte as a potentially useful endpoint for determination of contact sensitization potential of low molecular weight chemicals. The aim of the present article is to further exploit the performance of the NCTC 2544 assay. NCTC 2544 is a commercially available skin epithelial-like cell line originating from normal human skin, which posses a good expression of cytochrome P450-dependent enzymatic activities. Cells were exposed to contact allergens (2-bromo-2-bromomethyl glutaronitrile, cinnamaldehyde, citral, diethylmaleate, dinitrochlorobenzene, glyoxal, 2-mercaptobenzothiazole, nickel sulfate, 4-nitrobenzylbromide, oxazolone, penicillin G, resorcinol, tetramethylthiuram disulfide), to pre- pro-haptens (cinnamyl alcohol, eugenol, isoeugenol, p-phenylediamine), to respiratory allergens (ammonium hexachloroplatinate, diphenylmethane diisocyanate, glutaraldehyde, hexamethylenediisocyanate, maleic anhydride, trimellitic anhydride) and to irritants (benzaldehyde, cholorobenzene, diethylphtalate, hydrobenzoic acid, lactic acid, octanoic acid, phenol, salicylic acid, sodium lauryl sulphate, sulfamic acid). Cell associated IL-18 was evaluated 24 later by ELISA. At not-cytotoxic concentrations (cell viability higher of 80%, as assessed by MTT reduction assay), all contact sensitizers, including pre-pro-haptens, induced a dose-related increase in IL-18, whereas both irritants, with the exception of sulfamic acid, and respiratory allergens failed. A total of 33 chemicals were tested, with an overall accuracy of 97%. Overall, results obtained indicated that cell-associated IL-18 might provide an in vitro tool for identification and discrimination of contact vs. respiratory

  4. Investigating the effect of silicon surface chemical treatment on Al/Si contact properties in GaP/Si solar cells

    Science.gov (United States)

    Kudryashov, D.; Gudovskikh, A.

    2018-03-01

    In the present work, experimental studies have been carried out to reveal how chemical treatment of a silicon surface affects the properties of the Al/Si contact. It has been shown that for p-type monocrystalline silicon substrates with a resistivity of 10 ohm cm, it is possible to form an ohmic Al/Si contact by magnetron sputtering of an aluminum thin film and its further annealing at temperatures of 400 - 450 °C. In the range of annealing temperatures of 250 - 400 °C, the Si substrate treatment in the HF solution leads to a significant increase in currents on the current-voltage curves of the Al/Si contact, while in the range of 450 - 700 °C, the effect of chemical treatment of the silicon is not detected.

  5. Colors and contact dermatitis.

    Science.gov (United States)

    Bonamonte, Domenico; Foti, Caterina; Romita, Paolo; Vestita, Michelangelo; Angelini, Gianni

    2014-01-01

    The diagnosis of skin diseases relies on several clinical signs, among which color is of paramount importance. In this review, we consider certain clinical presentations of both eczematous and noneczematous contact dermatitis in which color plays a peculiar role orientating toward the right diagnosis. The conditions that will be discussed include specific clinical-morphologic subtypes of eczematous contact dermatitis, primary melanocytic, and nonmelanocytic contact hyperchromia, black dermographism, contact chemical leukoderma, and others. Based on the physical, chemical, and biologic factors underlying a healthy skin color, the various skin shades drawing a disease picture are thoroughly debated, stressing their etiopathogenic origins and histopathologic aspects.

  6. Contact sensitization in Dutch children and adolescents with and without atopic dermatitis - a retrospective analysis.

    Science.gov (United States)

    Lubbes, Stefanie; Rustemeyer, Thomas; Sillevis Smitt, Johannes H; Schuttelaar, Marie Louise; Middelkamp-Hup, Maritza A

    2017-03-01

    Allergic contact dermatitis is known to occur in children with and without atopic dermatitis, but more data are needed on contact sensitization profiles in these two groups. To identify frequent allergens in children with and without atopic dermatitis suspected of having allergic contact dermatitis. A retrospective analysis of children aged 0-17 years patch tested between 1996 and 2013 was performed. Of all 1012 children tested because of suspected contact dermatitis, 46% developed one or more positive reactions, the proportions for children with (n = 526) and without (n = 395) atopic dermatitis being 48% and 47%, respectively. Children with atopic dermatitis reacted more often to lanolin alcohol (30% pet., p = 0.030), Amerchol L-101 (p = 0.030), and fragrances [fragrance mix I (p = 0.048) and Myroxylon pereirae (p = 0.005)]. Allergens outside the European baseline series that frequently gave positive reactions in these groups included cocamidopropyl betaine and Amerchol L-101. Reactivity to these allergens was significantly more common in atopic dermatitis children. Sensitization prevalences in children with and without atopic dermatitis were similar, but children with atopic dermatitis reacted significantly more often to lanolin alcohol and fragrances. Testing with additional series besides the European baseline series may be necessary, as reactions to, for example, cocamidopropyl betaine and Amerchol L-101 may otherwise be missed. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Contact sensitization to cosmetic series of allergens in a general population in Beijing.

    Science.gov (United States)

    Zhao, Jian; Li, Lin-Feng

    2014-03-01

    Cosmetic allergic contact dermatitis (CACD) due to common cosmetic allergens in standard series has been extensively studied; however, the prevalence of contact allergy to other cosmetic allergens other than those in standard series is largely unknown. In this study, the frequency of contact sensitization to a European cosmetic series of allergens (Chemotechnique Diagnostics, Vellinge, Sweden) in healthy university student volunteers were detected in Beijing. Of 201 students studied, fifty-eight exhibited positive results, and 9 of them reported had cosmetics related dermatitis previously. The total positivity rate was not correlated to gender. The leading allergens were thimerosal (19.4%), shellac (3.0%), cocamidopropyl betaine (2.0%), hexamethylenetetramine (1.5%), dodecyl gallate (1.5%), hexahydro-1,3,5-tris-(2-hydroxyethyl)triazine (1.0%) and methyldibromo glutaronitrile (1.0%). The positivity rate of thimerosal patch test in men (9.8%) was lower than that of women (23.6%, P cosmetic allergens in men and women (P > 0.05, Chi square test). These results suggested that some cosmetic-related contact allergies may be missed by just testing patients with the European standard series or T.R.U.E. test system only, we recommend shellac, cocamidopropyl betaine, hexamethylenetetramine and dodecyl gallate as the additionally candidates for patch testing in patients with suspected CACD. © 2014 Wiley Periodicals, Inc.

  8. Application of Photocured Polymer Ion Selective Membranes for Solid-State Chemical Sensors

    Directory of Open Access Journals (Sweden)

    Natalia Abramova

    2015-06-01

    Full Text Available Application of conducting polymers with additional functional groups for a solid contact formation and photocurable membranes as sensitive elements of solid-state chemical sensors is discussed. Problems associated with application of UV-curable polymers for sensors are analyzed. A method of sensor fabrication using copolymerized conductive layer and sensitive membrane is presented and the proof of concept is confirmed by two examples of solid-contact electrodes for Ca ions and pH.

  9. Assessment of immunotoxicity induced by chemicals in human precision-cut lung slices (PCLS).

    Science.gov (United States)

    Lauenstein, L; Switalla, S; Prenzler, F; Seehase, S; Pfennig, O; Förster, C; Fieguth, H; Braun, A; Sewald, K

    2014-06-01

    Occupational asthma can be induced by a number of chemicals at the workplace. Risk assessment of potential sensitizers is mostly performed in animal experiments. With increasing public demand for alternative methods, human precision-cut lung slices (PCLS) have been developed as an ex vivo model. Human PCLS were exposed to increasing concentrations of 20 industrial chemicals including 4 respiratory allergens, 11 contact allergens, and 5 non-sensitizing irritants. Local respiratory irritation was characterized and expressed as 75% (EC25) and 50% (EC50) cell viability with respect to controls. Dose-response curves of all chemicals except for phenol were generated. Local respiratory inflammation was quantified by measuring the production of cytokines and chemokines. TNF-α and IL-1α were increased significantly in human PCLS after exposure to the respiratory sensitizers trimellitic anhydride (TMA) and ammonium hexachloroplatinate (HClPt) at subtoxic concentrations, while contact sensitizers and non-sensitizing irritants failed to induce the release of these cytokines to the same extent. Interestingly, significant increases in T(H)1/T(H)2 cytokines could be detected only after exposure to HClPt at a subtoxic concentration. In conclusion, allergen-induced cytokines were observed but not considered as biomarkers for the differentiation between respiratory and contact sensitizers. Our preliminary results show an ex vivo model which might be used for prediction of chemical-induced toxicity, but is due to its complex three-dimensional structure not applicable for a simple screening of functional and behavior changes of certain cell populations such as dendritic cells and T-cells in response to allergens. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Contact Angle and Adhesion Dynamics and Hysteresis on Molecularly Smooth Chemically Homogeneous Surfaces.

    Science.gov (United States)

    Chen, Szu-Ying; Kaufman, Yair; Schrader, Alex M; Seo, Dongjin; Lee, Dong Woog; Page, Steven H; Koenig, Peter H; Isaacs, Sandra; Gizaw, Yonas; Israelachvili, Jacob N

    2017-09-26

    Measuring truly equilibrium adhesion energies or contact angles to obtain the thermodynamic values is experimentally difficult because it requires loading/unloading or advancing/receding boundaries to be measured at rates that can be slower than 1 nm/s. We have measured advancing-receding contact angles and loading-unloading adhesion energies for various systems and geometries involving molecularly smooth and chemically homogeneous surfaces moving at different but steady velocities in both directions, ±V, focusing on the thermodynamic limit of ±V → 0. We have used the Bell Theory (1978) to derive expressions for the dynamic (velocity-dependent) adhesion energies and contact angles suitable for both (i) dynamic adhesion measurements using the classic Johnson-Kendall-Roberts (JKR, 1971) theory of "contact mechanics" and (ii) dynamic contact angle hysteresis measurements of both rolling droplets and syringe-controlled (sessile) droplets on various surfaces. We present our results for systems that exhibited both steady and varying velocities from V ≈ 10 mm/s to 1 nm/s, where in all cases but one, the advancing (V > 0) and receding (V contact angles converged toward the same theoretical (thermodynamic) values as V → 0. Our equations for the dynamic contact angles are similar to the classic equations of Blake & Haynes (1969) and fitted the experimental adhesion data equally well over the range of velocities studied, although with somewhat different fitting parameters for the characteristic molecular length/dimension or area and characteristic bond formation/rupture lifetime or velocity. Our theoretical and experimental methods and results unify previous kinetic theories of adhesion and contact angle hysteresis and offer new experimental methods for testing kinetic models in the thermodynamic, quasi-static, limit. Our analyses are limited to kinetic effects only, and we conclude that hydrodynamic, i.e., viscous, and inertial effects do not play a role at the

  11. Application of rat mast cell incubates as a possible short-time test for sensitizing occupational chemicals

    Energy Technology Data Exchange (ETDEWEB)

    Diel, F.; Neidhart, B.; Opree, W.

    1981-08-01

    The direct action of sensitizing occupational chemicals (formaldehyde, phenol, phenylhydrazine, p-aminophenol) on rat mast cells was investigated by determination of histamine using HPLC separation and fluorimetric detection. It turned out that dispersed mast cells from immunized and non-immunized Wistar-rats are more sensitive than small-cut lung tissue slices. Passive cutaneous anaphylaxis was negative after a fortnight sensitizing experiment with the here described occupational chemicals. Short-time tests with rat mast cells reflect anaphylactoid response and are suitable for the screening of sensitizing chemicals.

  12. A simple in chemico method for testing skin sensitizing potential of chemicals using small endogenous molecules.

    Science.gov (United States)

    Nepal, Mahesh Raj; Shakya, Rajina; Kang, Mi Jeong; Jeong, Tae Cheon

    2018-06-01

    Among many of the validated methods for testing skin sensitization, direct peptide reactivity assay (DPRA) employs no cells or animals. Although no immune cells are involved in this assay, it reliably predicts the skin sensitization potential of a chemical in chemico. Herein, a new method was developed using endogenous small-molecular-weight compounds, cysteamine and glutathione, rather than synthetic peptides, to differentiate skin sensitizers from non-sensitizers with an accuracy as high as DPRA. The percent depletion of cysteamine and glutathione by test chemicals was measured by an HPLC equipped with a PDA detector. To detect small-size molecules, such as cysteamine and glutathione, a derivatization by 4-(4-dimethylaminophenylazo) benzenesulfonyl chloride (DABS-Cl) was employed prior to the HPLC analysis. Following test method optimization, a cut-off criterion of 7.14% depletion was applied to differentiate skin sensitizers from non-sensitizers in combination of the ratio of 1:25 for cysteamine:test chemical with 1:50 for glutathione:test chemical for the best predictivity among various single or combination conditions. Although overlapping HPLC peaks could not be fully resolved for some test chemicals, high levels of sensitivity (100.0%), specificity (81.8%), and accuracy (93.3%) were obtained for 30 chemicals tested, which were comparable or better than those achieved with DPRA. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Nanoscopic platinum particles on TiO{sub 2}(110). STM and point-contact studies on the chemical and photosensitivity; Nanoskopische Platin-Teilchen auf TiO{sub 2}(110). STM- und Punktkontaktuntersuchungen zur chemischen und Photosensitivitaet

    Energy Technology Data Exchange (ETDEWEB)

    Koelbach, Johannes Micha

    2009-06-23

    In the ultra high vacuum produced nanoscopical platinum particles on TiO{sub 2}(110)- single crystal surfaces are contacted with the tunneltip of a raster tunnel microscope, and the chemical as well as photo sensitivity of an individual hetero contact are determined. For the experiments a UHV equipment was developed, equipped with methods to the controlled preparation and surface-analytic techniques (LEED, AES and STM). Platinum is resistively evaporated and thus small platinum particles with a size of about 8nm are generated on the pure titanium dioxide surface and characterized by STM and STS. A new developed oxygen source based on zirconoxide ceramics enables in-situ experiments for undisturbed determination of current-voltage characteristics in the tunneling and contact mode. A special preamplifier with controllable range of amplification is applied. Applying a voltage to the ceramic oxygen can be let into the UHV chamber by the oxygen source and the partial pressure can be adjusted within the range of 1.10{sup -10} mbar to 1.10{sup -5} mbar. The effect of the oxygen on the electrical characteristics of the Pt/TiO{sub 2}-contacts was proven. The clear dependence of the current-voltage characteristics on the oxygen partial pressure can be explained as a result of interface states due to the dissociation and adsorption of the oxygen, which determine the electrical characteristic of the contact. Schottky barriere heights and quality parameters were determined and compared with values of macroscopic surface contacts. For the investigations of the photo sensitivity a special STM head was developed, which enables the coupling of laser light with a wavelength of 413.1 nm. Irradiation of the nanoscopical Pt/TiO{sub 2}-contacts changes the current-voltage characteristics as well. The results of the power-dependent measurements refer to a temperature effect, that dominates the photoelectric effect. The combined power-and oxygen partial pressure dependent measurements are

  14. A case of contact dermatitis to dimethylfumarate in shoes identified in Italy

    Directory of Open Access Journals (Sweden)

    Franca Davanzo

    2010-12-01

    Full Text Available The present paper describes a case of shoe contact dermatitis from DMF identified by the Poison Control Centre of Milan (PCCM, Italy, in 2009. A 35 year old woman was affected by irritant reactions while wearing shoes contaminated with DMF. Exposure to these shoes was limited to a 8 hour period and was not repeated. In the following days the patient suffered feet blistering and swelling limited to the area in contact with shoe vamp. Topical application of cortisone did not prevent development of bullous eczema. After 20 days from exposure, the lesions were healed but the skin remained red, dry and very sensitive. Chemical analyses of shoes quantified an average concentration of DMF of 383 mg/kg. The patient refused to be patch tested. The observation here reported confirm that DMF should be considered a possible causal agent in shoe contact dermatitis. Documentation of cases exposed to this chemical provide a relevant support to characterize clinical manifestations and to identifying contaminated articles.

  15. Transparent front contact optimization in dye sensitized solar cells: use of cadmium stannate and titanium oxide by sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Braga, A., E-mail: antonio.braga@iit.it [CNR-IDASC SENSOR Lab and Department of Chemistry and Physics, Brescia University, Via Valotti 9, 25131 Brescia (Italy); Baratto, C. [CNR-IDASC SENSOR Lab and Department of Chemistry and Physics, Brescia University, Via Valotti 9, 25131 Brescia (Italy); Bontempi, E. [INSTM and Chemistry for Technologies Laboratory, University of Brescia, Via Branze 28, 25133 Brescia (Italy); Colombi, P. [Centro Coating C.S.M.T. Gestione S.c.a.r.l., Via Branze, 45 25123 Brescia (Italy); Sberveglieri, G. [CNR-IDASC SENSOR Lab and Department of Chemistry and Physics, Brescia University, Via Valotti 9, 25131 Brescia (Italy)

    2014-03-31

    A reliable transparent front contact of cadmium stannate (CTO) and titanium oxide (TiO{sub 2}) entirely deposited by magnetron sputtering has been studied and applied to build standard dye-sensitized solar cell. CTO gives very high average optical transmittance (T{sub avg} ≥ 90%) along with competitive sheet resistance (R{sub sheet} ≤ 15 Ω/sq), while a very thin layer of TiO{sub 2} (thickness < 5 nm) acts as buffer layer to prevent charge recombination. The matched materials allow achievement of good performances of the cells, in terms of short circuit current and power conversion efficiency. UV-visible spectrophotometry, glancing incident X-rays diffraction and X-rays reflectivity techniques were used to characterize thin films before cell realization; sealed solar cells were tested under simulated solar irradiance at 1 Sun to determine functional properties. - Highlights: • Double layer cadmium stannate–TiO{sub 2} transparent front contact by sputtering. • Very thin TiO{sub 2} buffer layer for charge recombination prevention. • Application of novel transparent contact in standard dye sensitized solar cells.

  16. Transparent front contact optimization in dye sensitized solar cells: use of cadmium stannate and titanium oxide by sputtering

    International Nuclear Information System (INIS)

    Braga, A.; Baratto, C.; Bontempi, E.; Colombi, P.; Sberveglieri, G.

    2014-01-01

    A reliable transparent front contact of cadmium stannate (CTO) and titanium oxide (TiO 2 ) entirely deposited by magnetron sputtering has been studied and applied to build standard dye-sensitized solar cell. CTO gives very high average optical transmittance (T avg ≥ 90%) along with competitive sheet resistance (R sheet ≤ 15 Ω/sq), while a very thin layer of TiO 2 (thickness < 5 nm) acts as buffer layer to prevent charge recombination. The matched materials allow achievement of good performances of the cells, in terms of short circuit current and power conversion efficiency. UV-visible spectrophotometry, glancing incident X-rays diffraction and X-rays reflectivity techniques were used to characterize thin films before cell realization; sealed solar cells were tested under simulated solar irradiance at 1 Sun to determine functional properties. - Highlights: • Double layer cadmium stannate–TiO 2 transparent front contact by sputtering. • Very thin TiO 2 buffer layer for charge recombination prevention. • Application of novel transparent contact in standard dye sensitized solar cells

  17. Auxetic Foam-Based Contact-Mode Triboelectric Nanogenerator with Highly Sensitive Self-Powered Strain Sensing Capabilities to Monitor Human Body Movement

    KAUST Repository

    Zhang, Steven L.; Lai, Ying-Chih; He, Xu; Liu, Ruiyuan; Zi, Yunlong; Wang, Zhong Lin

    2017-01-01

    The first contact-mode triboelectric self-powered strain sensor using an auxetic polyurethane foam, conductive fabric, and polytetrafluroethylene (PTFE) is fabricated. Utilizing the auxetic properties of the polyurethane foam, the auxetic polyurethane foam would expand into the PTFE when the foam is stretched, causing contact electrification. Due to a larger contact area between the PTFE and the foam as the foam is stretched, this device can serve effectively as a strain sensor. The sensitivity of this method is explored, and this sensor has the highest sensitivity in all triboelectric nanogenerator devices that are used previously as a strain sensor. Different applications of this strain sensor are shown, and this sensor can be used as a human body monitoring system, self-powered scale to measure weight, and a seat belt to measure body movements inside a car seat.

  18. Auxetic Foam-Based Contact-Mode Triboelectric Nanogenerator with Highly Sensitive Self-Powered Strain Sensing Capabilities to Monitor Human Body Movement

    KAUST Repository

    Zhang, Steven L.

    2017-05-15

    The first contact-mode triboelectric self-powered strain sensor using an auxetic polyurethane foam, conductive fabric, and polytetrafluroethylene (PTFE) is fabricated. Utilizing the auxetic properties of the polyurethane foam, the auxetic polyurethane foam would expand into the PTFE when the foam is stretched, causing contact electrification. Due to a larger contact area between the PTFE and the foam as the foam is stretched, this device can serve effectively as a strain sensor. The sensitivity of this method is explored, and this sensor has the highest sensitivity in all triboelectric nanogenerator devices that are used previously as a strain sensor. Different applications of this strain sensor are shown, and this sensor can be used as a human body monitoring system, self-powered scale to measure weight, and a seat belt to measure body movements inside a car seat.

  19. Resonant characteristics and sensitivity dependency on the contact surface in QCM-micropillar-based system of coupled resonator sensors

    International Nuclear Information System (INIS)

    Kashan, M A M; Kalavally, V; Ramakrishnan, N; Lee, H W

    2016-01-01

    We report the characteristics and sensitivity dependence over the contact surface in coupled resonating sensors (CRSs) made of high aspect ratio resonant micropillars attached to a quartz crystal microbalance (QCM). Through experiments and simulation, we observed that when the pillars of resonant heights were placed in maximum displacement regions the resonance frequency of the QCM increased following the coupled resonance characteristics, as the pillar offered elastic loading to the QCM surface. However, the same pillars when placed in relatively lower displacement regions, in spite of their resonant dimension, offered inertial loading and resulted in a decrease in QCM resonance frequency, as the displacement amplitude was insufficient to couple the vibrations from the QCM to the pillars. Accordingly, we discovered that the coupled resonance characteristics not only depend on the resonant structure dimensions but also on the contact regions in the acoustic device. Further analysis revealed that acoustic pressure at the contact surface also influences the resonance frequency characteristics and sensitivity of the CRS. To demonstrate the significance of the present finding for sensing applications, humidity sensing is considered as the example measurand. When a sensing medium made of resonant SU-8 pillars was placed in a maximum displacement region on a QCM surface, the sensitivity increased by 14 times in comparison to a resonant sensing medium placed in a lower displacement region of a QCM surface. (paper)

  20. Activation of non-sensitizing or low-sensitizing fragrance substances into potent sensitizers - prehaptens and prohaptens.

    Science.gov (United States)

    Karlberg, Ann-Therese; Börje, Anna; Duus Johansen, Jeanne; Lidén, Carola; Rastogi, Suresh; Roberts, David; Uter, Wolfgang; White, Ian R

    2013-12-01

    Experimental and clinical studies have shown that fragrance substances can act as prehaptens or prohaptens. They form allergens that are more potent than the parent substance by activation outside or in the skin via abiotic (chemical and physical factors) and/or biotic activation, thus, increasing the risk of sensitization. In the present review a series of fragrance substances with well documented abiotic and/or biotic activation are given as indicative and illustrative examples of the general problem. Commonly used fragrance substances, also found in essential oils, autoxidize on contact with air, forming potent sensitizers that can be an important source for contact allergy to fragrances and fragranced products. Some of them can act as prohaptens and be activated in the skin as well. The experimental findings are confirmed in large clinical studies. When substances with structural alerts for acting as prohaptens and/or prehaptens are identified, the possibility of generating new potent allergens should be considered. Predictive testing should include activation steps. Further experimental and clinical research regarding activation of fragrance substances is needed to increase consumer safety. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Simplistic graphene transfer process and its impact on contact resistance

    KAUST Repository

    Ghoneim, Mohamed T.; Smith, Casey; Hussain, Muhammad Mustafa

    2013-01-01

    Chemical vapor deposition based graphene grown on copper foil is attractive for electronic applications owing to its reliable growth process, large area coverage, and relatively defect free nature. However, transfer of the synthesized graphene to host substrate for subsequent device fabrication is extremely sensitive and can impact ultimate performance. Although ultra-high mobility is graphene's most prominent feature, problems with high contact resistance have severely limited its true potential. Therefore, we report a simple poly-(methyl methacrylate) based transfer process without post-annealing to achieve specific contact resistivity of 3.8 × 10−5 Ω cm2 which shows 80% reduction compared to previously reported values.

  2. Simplistic graphene transfer process and its impact on contact resistance

    KAUST Repository

    Ghoneim, Mohamed T.

    2013-05-09

    Chemical vapor deposition based graphene grown on copper foil is attractive for electronic applications owing to its reliable growth process, large area coverage, and relatively defect free nature. However, transfer of the synthesized graphene to host substrate for subsequent device fabrication is extremely sensitive and can impact ultimate performance. Although ultra-high mobility is graphene\\'s most prominent feature, problems with high contact resistance have severely limited its true potential. Therefore, we report a simple poly-(methyl methacrylate) based transfer process without post-annealing to achieve specific contact resistivity of 3.8 × 10−5 Ω cm2 which shows 80% reduction compared to previously reported values.

  3. Development of an in vitro skin sensitization test based on ROS production in THP-1 cells.

    Science.gov (United States)

    Saito, Kazutoshi; Miyazawa, Masaaki; Nukada, Yuko; Sakaguchi, Hitoshi; Nishiyama, Naohiro

    2013-03-01

    Recently, it has been reported that reactive oxygen species (ROS) produced by contact allergens can affect dendritic cell migration and contact hypersensitivity. The aim of the present study was to develop a new in vitro assay that could predict the skin sensitizing potential of chemicals by measuring ROS production in THP-1 (human monocytic leukemia cell line) cells. THP-1 cells were pre-loaded with a ROS sensitive fluorescent dye, 5-(and 6-)-chloromethyl-2', 7'-dichlorodihydrofluorescein diacetate, acetyl ester (CM-H2DCFDA), for 15min, then incubated with test chemicals for 30min. The fluorescence intensity was measured by flow cytometry. For the skin sensitizers, 25 out of 30 induced over a 2-fold ROS production at more than 90% of cell viability. In contrast, increases were only seen in 4 out of 20 non-sensitizers. The overall accuracy for the local lymph node assay (LLNA) was 82% for 50 chemicals tested. A correlation was found between the estimated concentration showing 2-fold ROS production in the ROS assay and the EC3 values (estimated concentration required to induce positive response) of the LLNA. These results indicated that the THP-1 cell-based ROS assay was a rapid and highly sensitive detection system able to predict skin sensitizing potentials and potency of chemicals. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. In vitro methods for hazard assessment of industrial chemicals – opportunities and challenges

    Directory of Open Access Journals (Sweden)

    Chin Lin eWong

    2015-05-01

    Full Text Available Allergic contact dermatitis (ACD is a delayed-type hypersensitivity immune reaction mediated by T-lymphocytes as a result of repeated exposure of an allergen primarily on skin. ACD accounts for up to 95% of occupational skin diseases (OSDs, with epoxy resins implicated as one of the most common causes of ACD. Efficient high-throughput in vitro screening for accurate identification of compounds and materials that may pose hazardous risks in the workplace is crucial. At present, the murine local lymph node assay (LLNA is the ‘method of choice’ for predicting the sensitizing potency of contact allergens. As the 3Rs principles of reduction, refinement and replacement in animal testing has gained political and economic momentum, several in vitro screening methods have been developed for identifying potential contact allergens. To date, these latter methods have been utilized primarily to assess the skin sensitizing potential of the chemical components of cosmetic products with scant research attention as to the applicability of these methods to industrial chemicals, particularly epoxy resins. Herein we review the currently utilized in vitro methods and identify the knowledge gaps with regard to assessing the generalizability of in vitro screening methods for assessing the skin sensitizing potential of industrial chemicals.

  5. Prospective multicenter survey on the clinical management of pediatric contact dermatitis.

    Science.gov (United States)

    Ruggiero, Giuseppe; Carnevale, Claudia; Diociaiuti, Andrea; Arcangeli, Fabio; El Hachem, May

    2016-12-01

    Contact dermatitis can be defined as an inflammatory process affecting the skin surface and induced by contact with chemical, physical and/or biotic agents in the environment. It causes lesions to skin, mucosae and semi-mucosae by means of allergic and irritant pathogenic mechanisms. Among the main triggers of contact dermatitis in the pediatric age are chemical or physical agents, which cause irritant contact dermatitis (ICD), and sensitizers, which cause a tissue damage through an allergic mechanism (allergic contact dermatitis [ACD]). A prospective, multicenter, observational study was carried out in 204 children affected by contact dermatitis, aged up to 14 years, and enrolled by pediatricians from 7 different Italian provinces. The diagnosis of contact dermatitis was based on the pediatrician's clinical evaluation. The data were collected through a series of simple and multiple choice questions, anonymously filled out by pediatricians. In 90% of cases (184 of 204 patients), there was complete remission of contact dermatitis, with no cases of worsening. No adverse events were observed, either. The effectiveness of the therapy was rated as "very effective" by 84.4% of the parents and 86.8% of the pediatricians. In only 10 patients a new therapy had to be prescribed. Contact dermatitis is a heterogeneous inflammatory skin disease induced by contact with different kinds of environmental agents. Cutaneous manifestations are highly variable and depend on the modality of contact, on the causative agent and on the pathogenesis. This Italian experience of a clinical approach to contact dermatitis stresses the need of daily skin care through different therapeutic strategies, based on the diagnosis, the clinical severity and the parents and children compliance. The first therapeutic measure to be implemented is prevention, through the removal of the causative agent and the use of protective devices. Indeed, preserving the skin's barrier function is an important goal and

  6. Tomato contact dermatitis

    DEFF Research Database (Denmark)

    Paulsen, Evy; Christensen, Lars P; Andersen, Klaus Ejner

    2012-01-01

    The tomato plant (Solanum lycopersicum) is an important crop worldwide. Whereas immediate-type reactions to tomato fruits are well known, contact dermatitis caused by tomatoes or tomato plants is rarely reported. The aims of this study were to present new data on contact sensitization to tomato...... plants and review the literature on contact dermatitis caused by both plants and fruits. An ether extract of tomato plants made as the original oleoresin plant extracts, was used in aimed patch testing, and between 2005 and 2011. 8 of 93 patients (9%) tested positive to the oleoresin extracts....... This prevalence is in accordance with the older literature that reports tomato plants as occasional sensitizers. The same applies to tomato fruits, which, in addition, may cause protein contact dermatitis. The allergens of the plant are unknown, but both heat-stable and heat-labile constituents seem...

  7. Research on removing reservoir core water sensitivity using the method of ultrasound-chemical agent for enhanced oil recovery.

    Science.gov (United States)

    Wang, Zhenjun; Huang, Jiehao

    2018-04-01

    The phenomenon of water sensitivity often occurs in the oil reservoir core during the process of crude oil production, which seriously affects the efficiency of oil extraction. In recent years, near-well ultrasonic processing technology attaches more attention due to its safety and energy efficient. In this paper, the comparison of removing core water sensitivity by ultrasonic wave, chemical injection and ultrasound-chemical combination technique are investigated through experiments. Results show that: lower ultrasonic frequency and higher power can improve the efficiency of core water sensitivity removal; the effects of removing core water sensitivity under ultrasonic treatment get better with increase of core initial permeability; the effect of removing core water sensitivity using ultrasonic treatment won't get better over time. Ultrasonic treatment time should be controlled in a reasonable range; the effect of removing core water sensitivity using chemical agent alone is slightly better than that using ultrasonic treatment, however, chemical injection could be replaced by ultrasonic treatment for removing core water sensitivity from the viewpoint of oil reservoir protection and the sustainable development of oil field; ultrasound-chemical combination technique has the best effect for water sensitivity removal than using ultrasonic treatment or chemical injection alone. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. radioactive survey on the contact zone (paleogene - neogene) in Ad-Daww basin of Syria, using alpha sensitive plastic film technique

    International Nuclear Information System (INIS)

    Mouty, M.; Al-Hilal, M.; Kattaa, B.

    1995-01-01

    A detailed radon survey has been carried out over the contact zone of marine Paleogene and continental Neogene Formations in Ad-Daww basin (Central Syria), for the purpose of uranium exploration. Radon measurements were performed in a grid pattern using alpha sensitive plastic film technique, type 1B CN-85. Radon concentrations in soil were monitored across the aforementioned zone for 1.5 year, from April 93 to July 94, and their average has been calculated. Alpha Track density was found to be varying from 81 to 227 T/mm2 in Qarytein station, 65 to 124 T/mm2 in Bardeh station and 101 to 196 T/mm2 in Tyas station. The results of this work showed that the anomalous radon values were found to be corresponded to the Oligocene-Miocene geological surface in the study area. These relatively high values are most likely related to scattered uranium mineralization precipitated on surface along a chemically reducing zone where surface water of terrestrial and marine origin intermingled. A comparison between gamma count rate and trak etch density revealed a fairly good correlation, which indicates that the uranium occurrences on the geological contact (Oli - Mio) in Ad-Daww basin are of surficial nature. However, this may give a preliminary indication of probable subsurface extension of these occurrences preserved at depth away from surfacial weathering. (author). 6 refs., 2 tabs

  9. Occupational allergic and irritant contact dermatitis in workers exposed to polyurethane foam

    Directory of Open Access Journals (Sweden)

    Marta Kieć-Świerczyńska

    2014-04-01

    Full Text Available Objectives: To evaluate sensitization to chemicals present in work environment after an outbreak of contact dermatitis in workers of vehicle equipment factory, exposed to polyurethane foam, based on 4,4'-diphenylmethane diisocyanate (MDI. Material and Methods: From among 300 employees, 21 individuals reporting work-related skin and/or respiratory tract symptoms underwent clinical examination, patch testing, skin prick tests, spirometry and MDI sIgE measurement in serum. Patch tests included isocyanates series, selected rubber additives, metals, fragrances, preservatives, and an antiadhesive agent. Results: Clinical examination revealed current eczema in the area of hands and/or forearms in 10 workers. Positive patch test reactions were found in 10 individuals, the most frequent to diaminodiphenylmethane and 4-phenylenediamine (7 persons. Reactions to an antiadhesive agent were assessed as irritant (5 workers. Except for sensitization to common aeroallergens, no significant abnormalities were found in the remaining tests. Occupational allergic contact dermatitis was diagnosed in 7 workers, irritant contact dermatitis in 10 and coexisiting allergic and irritant contact dermatitis in 3 workers. Conclusions: In workers manufacturing products from polyurethane foam, attention should be paid to the risk of developing contact dermatitis. Skin problems in our study group were attributable probably to insufficient protection of the skin.

  10. The potential pathogenicity of chlorhexidine-sensitive Acanthamoeba strains isolated from contact lens cases from asymptomatic individuals in Tenerife, Canary Islands, Spain.

    Science.gov (United States)

    Martín-Navarro, Carmen M; Lorenzo-Morales, Jacob; Cabrera-Serra, M Gabriela; Rancel, Fernando; Coronado-Alvarez, Nieves M; Piñero, José E; Valladares, Basilio

    2008-11-01

    Pathogenic strains of the genus Acanthamoeba are causative agents of a serious sight-threatening infection of the eye known as Acanthamoeba keratitis. The prevalence of this infection has risen in the past 20 years, mainly due to the increase in number of contact lens wearers. In this study, the prevalence of Acanthamoeba in a risk group constituted by asymptomatic contact lens wearers from Tenerife, Canary Islands, Spain, was evaluated. Contact lenses and contact lens cases were analysed for the presence of Acanthamoeba isolates. The isolates' genotypes were also determined after rDNA sequencing. The pathogenic potential of the isolated strains was subsequently established using previously described molecular and biochemical assays, which allowed the selection of three strains with high pathogenic potential. Furthermore, the sensitivity of these isolates against two standard drugs, ciprofloxacin and chlorhexidine, was analysed. As the three selected strains were sensitive to chlorhexidine, its activity and IC(50) were evaluated. Chlorhexidine was found to be active against these strains and the obtained IC(50) values were compared to the concentrations of this drug present in contact lens maintenance solutions. It was observed that the measured IC(50) was higher than the concentration found in these maintenance solutions. Therefore, the ineffectiveness of chlorhexidine-containing contact lens maintenance solutions against potentially pathogenic strains of Acanthamoeba is demonstrated in this study.

  11. Perfume sensitivity in adult females. A study of contact sensitivity to a perfume mix in two groups of student nurses.

    Science.gov (United States)

    Guin, J D; Berry, V K

    1980-09-01

    The incidence of contact sensitivity to a perfume mix was investigated in two groups of student nurses by questionnaire and patch testing. Twenty-nine of ninety gave a history of dermatitis on exposure to fragrances or perfumed cosmetics. Fifteen of eighty-five showed a positive patch test reaction to a perfume mix comprising 2% concentrations of eight different perfume ingredients, and twelve of the fifteen had a positive history. Chi-square analysis of the data indicates that the results of the two methods of measurements are significantly related (p < 0.0001).

  12. Identifying airway sensitizers: cytokine mRNA profiles induced by various anhydrides

    International Nuclear Information System (INIS)

    Plitnick, L.M.; Loveless, S.E.; Ladics, G.S.; Holsapple, M.P.; Smialowicz, R.J.; Woolhiser, M.R.; Anderson, P.K.; Smith, C.; Selgrade, M.J.K.

    2003-01-01

    Exposure to low molecular weight (LMW) chemicals in the workplace has been linked to a variety of respiratory effects. Within the LMW chemicals, one of the major classes involved in these effects are the acid anhydrides. The immunological basis of respiratory hypersensitivity involves CD4+ cells. By virtue of their induction of cytokines typical of CD4+ T-helper type 2 (Th2) cells--interleukin (IL)-4, 10, and 13--respiratory sensitizers may be identified and differentiated from contact sensitizers which induce Th1 cytokines (IL-2 and IFN-γ). Our previous work suggested that the ribonuclease protection assay (RPA) was useful in identifying the respiratory sensitizer, trimellitic anhydride (TMA), based on quantitative differences in Th2 cytokine mRNA as compared to the contact sensitizer dinitrochlorobenzene (DNCB). Therefore, the purpose of the studies described in this report was to expand the chemicals tested in the RPA. To this end, four acid anhydrides with known respiratory sensitization potential, TMA, maleic anhydride (MA), phthalic anhydride (PA) and hexahydrophthalic anhydride (HHPA), were tested. Although previously determined to induce immunologically equivalent responses in a local lymph node assay (LLNA), the initial dose chosen (2.5%) failed to induce Th2 cytokine mRNA expression. To determine if the lack of cytokine expression was related to dose, LLNAs were conducted at higher doses for each of the anhydrides. The highest doses evaluated (four- to six-fold higher than those used in the initial RPA) gave equivalent proliferative responses for the various anhydrides and were used for subsequent RPA testing. At these higher doses, significant increases in Th2 versus Th1 cytokine mRNA were observed for all anhydrides tested. These results suggest that the RPA has the potential to serve as a screen for the detection of LMW airway sensitizing chemicals. However, the basis for selecting immunologically equivalent doses may require some modification

  13. The local lymph node assay and skin sensitization testing.

    Science.gov (United States)

    Kimber, Ian; Dearman, Rebecca J

    2010-01-01

    The mouse local lymph node assay (LLNA) is a method for the identification and characterization of skin sensitization hazards. In this context the method can be used both to identify contact allergens, and also determine the relative skin sensitizing potency as a basis for derivation of effective risk assessments.The assay is based on measurement of proliferative responses by draining lymph node cells induced following topical exposure of mice to test chemicals. Such responses are known to be causally and quantitatively associated with the acquisition of skin sensitization and therefore provide a relevant marker for characterization of contact allergic potential.The LLNA has been the subject of exhaustive evaluation and validation exercises and has been assigned Organization for Economic Cooperation and Development (OECD) test guideline 429. Herein we describe the conduct and interpretation of the LLNA.

  14. Evaluation of selected biomarkers for the detection of chemical sensitization in human skin: a comparative study applying THP-1, MUTZ-3 and primary dendritic cells in culture.

    Science.gov (United States)

    Hitzler, Manuel; Bergert, Antje; Luch, Andreas; Peiser, Matthias

    2013-09-01

    Dendritic cells (DCs) exhibit the unique capacity to induce T cell differentiation and proliferation, two processes that are crucially involved in allergic reactions. By combining the exclusive potential of DCs as the only professional antigen-presenting cells of the human body with the well known handling advantages of cell lines, cell-based alternative methods aimed at detecting chemical sensitization in vitro commonly apply DC-like cells derived from myeloid cell lines. Here, we present the new biomarkers programmed death-ligand 1 (PD-L1), DC immunoreceptor (DCIR), IL-16, and neutrophil-activating protein-2 (NAP-2), all of which have been detectable in primary human DCs upon exposure to chemical contact allergens. To evaluate the applicability of DC-like cells in the prediction of a chemical's sensitization potential, the expression of cell surface PD-L1 and DCIR was analyzed. In contrast to primary DCs, only minor subpopulations of MUTZ-3 and THP-1 cells presented PD-L1 or DCIR at their surface. After exposure to increasing concentrations of nickel and cinnamic aldehyde, the expression level of PD-L1 and DCIR revealed much stronger affected on monocyte-derived DCs (MoDCs) or Langerhans cells (MoLCs) when compared to THP-1 and MUTZ-3 cells. Applying protein profiler arrays we further identified the soluble factors NAP-2, IL-16, IL-8 and MIP-1α as sensitive biomarkers showing the capacity to discriminate sensitizing from non-sensitizing chemicals or irritants. An allergen-specific release of IL-8 and MIP-1α could be detected in the supernatants of MoDCs and MoLCs and also in MUTZ-3 and THP-1 cells, though at much lower levels. On the protein and transcriptional level, NAP-2 and IL-16 indicated sensitizers most sensitively and specifically in MoDCs. Altogether, we have proven the reciprocal regulated surface molecules PD-L1 and DCIR and the soluble factors MIP-1α, NAP-2 and IL-16 as reliable biomarkers for chemical sensitization. We further show that primary

  15. Aqueous media treatment and decontamination of hazardous chemical and biological substances by contact plasma

    International Nuclear Information System (INIS)

    Pivovarov, A.; Kravchenko, A.; Kublanovsky, V.

    2009-01-01

    Usage of non-equilibrium contact plasma for processes of decontamination and neutralization in conditions of manifestation of chemical, biological and radiation terrorism takes on special significance due to portability of equipment and its mobility in places where toxic liquid media hazardous for people's health are located. Processes of decontamination of aqueous media, seminated with pathogenic microorganisms and viruses, treatment of water containing toxic heavy metals, cyanides, surface-active substances, and heavy radioactive elements, are investigated. Examples of activation processes in infected water and toxic aqueous solutions present convincing evidence of the way, how new quality technological approach for achievement of high enough degree of the said media treatment is used in each specific case. Among new properties of water activated as a result of action of non-equilibrium contact plasma, it is necessary to mention presence of cluster structure, confirmed by well-known spectral and physical-chemical methods, presence of peroxide compounds, active particles and radicals. Anti-microbial activity which is displayed under action of plasma in aqueous media (chemically pure water, drinking water, aqueous solutions of sodium chloride, potassium iodide, as well as other inorganic compounds) towards wide range of pathogenic and conventionally pathogenic microorganisms allows use them as reliable, accessible and low-cost preparations for increasing the degree of safety of food products. Combination of such processes with known methods of filtration and ultra-filtration gives an efficient and available complex capable of withstanding any threats, which may arise for population and living organisms. Present-day level of machine-building, electrical engineering, and electronics allows predict creation of industrial plasma installations, adapted to conditions of various terrorist threats, with minimized power consumption and optimized technological parameters

  16. Aqueous media treatment and decontamination of hazardous chemical and biological substances by contact plasma

    Energy Technology Data Exchange (ETDEWEB)

    Pivovarov, A; Kravchenko, A [Ukrainian State University of Chemical Engineering, Dnepropetrovsk (Ukraine); Kublanovsky, V [V. I. Vernadsky Institute of General and Inorganic Chemistry of National Academy of Science, Kiev (Ukraine)

    2009-07-01

    Usage of non-equilibrium contact plasma for processes of decontamination and neutralization in conditions of manifestation of chemical, biological and radiation terrorism takes on special significance due to portability of equipment and its mobility in places where toxic liquid media hazardous for people's health are located. Processes of decontamination of aqueous media, seminated with pathogenic microorganisms and viruses, treatment of water containing toxic heavy metals, cyanides, surface-active substances, and heavy radioactive elements, are investigated. Examples of activation processes in infected water and toxic aqueous solutions present convincing evidence of the way, how new quality technological approach for achievement of high enough degree of the said media treatment is used in each specific case. Among new properties of water activated as a result of action of non-equilibrium contact plasma, it is necessary to mention presence of cluster structure, confirmed by well-known spectral and physical-chemical methods, presence of peroxide compounds, active particles and radicals. Anti-microbial activity which is displayed under action of plasma in aqueous media (chemically pure water, drinking water, aqueous solutions of sodium chloride, potassium iodide, as well as other inorganic compounds) towards wide range of pathogenic and conventionally pathogenic microorganisms allows use them as reliable, accessible and low-cost preparations for increasing the degree of safety of food products. Combination of such processes with known methods of filtration and ultra-filtration gives an efficient and available complex capable of withstanding any threats, which may arise for population and living organisms. Present-day level of machine-building, electrical engineering, and electronics allows predict creation of industrial plasma installations, adapted to conditions of various terrorist threats, with minimized power consumption and optimized technological parameters

  17. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Costume Contacts May Contain Chemicals Harmful to Eyes Four Ways Over-the-Counter Costume Contact Lenses Can ... was in severe pain and on medication for four weeks, and couldn't see well enough to ...

  18. Suitability of macrophage inflammatory protein-1beta production by THP-1 cells in differentiating skin sensitizers from irritant chemicals.

    Science.gov (United States)

    Lim, Yeon-Mi; Moon, Seong-Joon; An, Su-Sun; Lee, Soo-Jin; Kim, Seo-Young; Chang, Ih-Seop; Park, Kui-Lea; Kim, Hyoung-Ah; Heo, Yong

    2008-04-01

    Worldwide restrictions in animal use for research have driven efforts to develop alternative methods. The study aimed to test the efficacy of the macrophage inflammatory protein-1beta (MIP-1beta) assay for testing chemicals' skin-sensitizing capacity. The assay was performed using 9 chemicals judged to be sensitizing and 7 non-sensitizing by the standard in vivo assays. THP-1 cells were cultured in the presence or absence of 4 doses, 0.01x, 0.1x, 0.5x, or 1x IC(50) (50% inhibitory concentration for THP-1 cell proliferation) of these chemicals for 24 hr, and the MIP-1beta level in the supernatants was determined. Skin sensitization by the test chemicals was determined by MIP-1beta production rates. The MIP-1beta production rate was expressed as the relative increase in MIP-1beta production in response to chemical treatment compared with vehicle treatment. When the threshold MIP-1beta production rate used was 100% or 105% of dimethyl sulfoxide, all the sensitizing chemicals tested (dinitrochlorobenzene, hexyl cinnamic aldehyde, eugenol, hydroquinone, dinitrofluorobenzene, benzocaine, nickel, chromium, and 5-chloro-2-methyl-4-isothiazolin-3-one) were positive, and all the non-sensitizing chemicals (methyl salicylate, benzalkonium chloride, lactic acid, isopropanol, and salicylic acid), with the exception of sodium lauryl sulfate, were negative for MIP-1beta production. These results indicate that MIP-1beta could be a biomarker for classification of chemicals as sensitizers or non-sensitizers.

  19. Pred-Skin: A Fast and Reliable Web Application to Assess Skin Sensitization Effect of Chemicals.

    Science.gov (United States)

    Braga, Rodolpho C; Alves, Vinicius M; Muratov, Eugene N; Strickland, Judy; Kleinstreuer, Nicole; Trospsha, Alexander; Andrade, Carolina Horta

    2017-05-22

    Chemically induced skin sensitization is a complex immunological disease with a profound impact on quality of life and working ability. Despite some progress in developing alternative methods for assessing the skin sensitization potential of chemical substances, there is no in vitro test that correlates well with human data. Computational QSAR models provide a rapid screening approach and contribute valuable information for the assessment of chemical toxicity. We describe the development of a freely accessible web-based and mobile application for the identification of potential skin sensitizers. The application is based on previously developed binary QSAR models of skin sensitization potential from human (109 compounds) and murine local lymph node assay (LLNA, 515 compounds) data with good external correct classification rate (0.70-0.81 and 0.72-0.84, respectively). We also included a multiclass skin sensitization potency model based on LLNA data (accuracy ranging between 0.73 and 0.76). When a user evaluates a compound in the web app, the outputs are (i) binary predictions of human and murine skin sensitization potential; (ii) multiclass prediction of murine skin sensitization; and (iii) probability maps illustrating the predicted contribution of chemical fragments. The app is the first tool available that incorporates quantitative structure-activity relationship (QSAR) models based on human data as well as multiclass models for LLNA. The Pred-Skin web app version 1.0 is freely available for the web, iOS, and Android (in development) at the LabMol web portal ( http://labmol.com.br/predskin/ ), in the Apple Store, and on Google Play, respectively. We will continuously update the app as new skin sensitization data and respective models become available.

  20. Some Sensitivity Studies of Chemical Transport Simulated in Models of the Soil-Plant-Litter System

    Energy Technology Data Exchange (ETDEWEB)

    Begovich, C.L.

    2002-10-28

    Fifteen parameters in a set of five coupled models describing carbon, water, and chemical dynamics in the soil-plant-litter system were varied in a sensitivity analysis of model response. Results are presented for chemical distribution in the components of soil, plants, and litter along with selected responses of biomass, internal chemical transport (xylem and phloem pathways), and chemical uptake. Response and sensitivity coefficients are presented for up to 102 model outputs in an appendix. Two soil properties (chemical distribution coefficient and chemical solubility) and three plant properties (leaf chemical permeability, cuticle thickness, and root chemical conductivity) had the greatest influence on chemical transport in the soil-plant-litter system under the conditions examined. Pollutant gas uptake (SO{sub 2}) increased with change in plant properties that increased plant growth. Heavy metal dynamics in litter responded to plant properties (phloem resistance, respiration characteristics) which induced changes in the chemical cycling to the litter system. Some of the SO{sub 2} and heavy metal responses were not expected but became apparent through the modeling analysis.

  1. Sevoflurane anaesthesia for nasal surgery in a patient with multiple chemical sensitivity.

    Science.gov (United States)

    Fernández Martín, M T; Álvarez López, J C

    2018-01-01

    Multiple chemical sensitivity syndrome is a group of complex disorders that include psychiatric disorders, chronic fatigue and/or respiratory problems. This syndrome could be triggered by specific allergens and toxins that cause neurophysiological sensitization and the appearance of the clinical symptomatology. Anaesthesia for these patients always poses a challenge for the anaesthetist, because they need to find and use drugs that do not trigger or aggravate the symptoms of the disease. Therefore, sevoflurane in these circumstances might be "the ideal anaesthetic". Performing general anaesthesia with sevoflurane as the sole anaesthetic agent, together with a series of environmental measures formed the basis for successful anaesthesia and surgery in our patient with a multiple chemical sensitivity syndrome. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Fabrication and characterization of a multidirectional-sensitive contact-enhanced inertial microswitch with a electrophoretic flexible composite fixed electrode

    International Nuclear Information System (INIS)

    Yang, Zhuoqing; Zhu, Bin; Chen, Wenguo; Ding, Guifu; Wang, Hong; Zhao, Xiaolin

    2012-01-01

    A multidirectional-sensitive inertial microswitch with a polymer–metal composite fixed electrode has been designed and fabricated based on surface micromachining in this work. The microswitch mainly consists of a suspended proof mass as a movable electrode and a T-shaped structure on the substrate with maple leaf-like top and cantilevers around the central cylinder as vertical and lateral fixed electrodes. It can sense the applied shock accelerations from any radial direction in the xoy plane and z-axis. The new vertical composite fixed electrode of the switch is completed by electroplating and electrophoretic deposition, which can realize a flexible contact between the electrodes and reduce the bounces and prolong the contact time. As a result, the stability and reliability of the inertial switch could be greatly improved. The fabricated microswitches have been tested and characterized by a standard dropping hammer system. It is shown that the threshold acceleration of the prototype is generally uniform in different sensitive directions in the xoy plane and z-axis, which is about 70 g. The contact time of the microswitch with the composite fixed electrode is ∼110 µs in the vertical direction, which is longer than that (∼65 µs) without a polymer. The test data are in agreement with dynamic finite-element simulation results. (paper)

  3. Chemical allergens stimulate human epidermal keratinocytes to produce lymphangiogenic vascular endothelial growth factor

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Ok-Nam [College of Pharmacy, Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan 426-791 (Korea, Republic of); Ahn, Seyeon; Jin, Sun Hee; Hong, Soo Hyun; Lee, Jinyoung [College of Pharmacy, Natural Products Research Institute, Seoul National University, Seoul 151-742 (Korea, Republic of); Kim, Eun-Sun [College of Pharmacy, Institute of Pharmaceutical Science and Technology, Hanyang University, Ansan 426-791 (Korea, Republic of); Jeong, Tae Cheon [College of Pharmacy, Yeungnam University, Gyeongsan 712-749 (Korea, Republic of); Chun, Young-Jin [College of Pharmacy, Chung-Ang University, Seoul 156-756 (Korea, Republic of); Lee, Ai-Young, E-mail: leeay@duih.org [Department of Dermatology, Dongguk University Ilsan Hospital, Goyang 410-773 (Korea, Republic of); Noh, Minsoo, E-mail: minsoo@alum.mit.edu [College of Pharmacy, Natural Products Research Institute, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2015-03-01

    Allergic contact dermatitis (ACD) is a cell-mediated immune response that involves skin sensitization in response to contact with various allergens. Angiogenesis and lymphangiogenesis both play roles in the allergic sensitization process. Epidermal keratinocytes can produce vascular endothelial growth factor (VEGF) in response to UV irradiation and during wound healing. However, the effect of haptenic chemical allergens on the VEGF production of human keratinocytes, which is the primary contact site of toxic allergens, has not been thoroughly researched. We systematically investigated whether immune-regulatory cytokines and chemical allergens would lead to the production of VEGF in normal human keratinocytes (NHKs) in culture. VEGF production significantly increased when NHKs were treated with IFNγ, IL-1α, IL-4, IL-6, IL-17A, IL-22 or TNFα. Among the human sensitizers listed in the OECD Test Guideline (TG) 429, we found that CMI/MI, DNCB, 4-phenylenediamine, cobalt chloride, 2-mercaptobenzothiazole, citral, HCA, cinnamic alcohol, imidazolidinyl urea and nickel chloride all significantly upregulated VEGF production in NHKs. In addition, common human haptenic allergens such as avobenzone, formaldehyde and urushiol, also induced the keratinocyte-derived VEGF production. VEGF upregulation by pro-inflammatory stimuli, IFNγ, DNCB or formaldehyde is preceded by the production of IL-8, an acute inflammatory phase cytokine. Lymphangiogenic VEGF-C gene transcription was significantly increased when NHKs were treated with formaldehyde, DNCB or urushiol, while transcription of VEGF-A and VEGF-B did not change. Therefore, the chemical allergen-induced VEGF upregulation is mainly due to the increase in lymphangiogenic VEGF-C transcription in NHKs. These results suggest that keratinocyte-derived VEGF may regulate the lymphangiogenic process during the skin sensitization process of ACD. - Highlights: • Pro-inflammatory cytokines induced VEGF production in normal human

  4. Chemical allergens stimulate human epidermal keratinocytes to produce lymphangiogenic vascular endothelial growth factor

    International Nuclear Information System (INIS)

    Bae, Ok-Nam; Ahn, Seyeon; Jin, Sun Hee; Hong, Soo Hyun; Lee, Jinyoung; Kim, Eun-Sun; Jeong, Tae Cheon; Chun, Young-Jin; Lee, Ai-Young; Noh, Minsoo

    2015-01-01

    Allergic contact dermatitis (ACD) is a cell-mediated immune response that involves skin sensitization in response to contact with various allergens. Angiogenesis and lymphangiogenesis both play roles in the allergic sensitization process. Epidermal keratinocytes can produce vascular endothelial growth factor (VEGF) in response to UV irradiation and during wound healing. However, the effect of haptenic chemical allergens on the VEGF production of human keratinocytes, which is the primary contact site of toxic allergens, has not been thoroughly researched. We systematically investigated whether immune-regulatory cytokines and chemical allergens would lead to the production of VEGF in normal human keratinocytes (NHKs) in culture. VEGF production significantly increased when NHKs were treated with IFNγ, IL-1α, IL-4, IL-6, IL-17A, IL-22 or TNFα. Among the human sensitizers listed in the OECD Test Guideline (TG) 429, we found that CMI/MI, DNCB, 4-phenylenediamine, cobalt chloride, 2-mercaptobenzothiazole, citral, HCA, cinnamic alcohol, imidazolidinyl urea and nickel chloride all significantly upregulated VEGF production in NHKs. In addition, common human haptenic allergens such as avobenzone, formaldehyde and urushiol, also induced the keratinocyte-derived VEGF production. VEGF upregulation by pro-inflammatory stimuli, IFNγ, DNCB or formaldehyde is preceded by the production of IL-8, an acute inflammatory phase cytokine. Lymphangiogenic VEGF-C gene transcription was significantly increased when NHKs were treated with formaldehyde, DNCB or urushiol, while transcription of VEGF-A and VEGF-B did not change. Therefore, the chemical allergen-induced VEGF upregulation is mainly due to the increase in lymphangiogenic VEGF-C transcription in NHKs. These results suggest that keratinocyte-derived VEGF may regulate the lymphangiogenic process during the skin sensitization process of ACD. - Highlights: • Pro-inflammatory cytokines induced VEGF production in normal human

  5. Chemosensory perception, symptoms and autonomic responses during chemical exposure in multiple chemical sensitivity

    DEFF Research Database (Denmark)

    Andersson, Linus; Claeson, Anna Sara; Dantoft, Thomas Meinertz

    2016-01-01

    Purpose: Multiple chemical sensitivity (MCS) is a prevalent medically unexplained symptom characterized by symptom reactions to everyday chemical exposure below hygienic thresholds. The aim of this study was to investigate the expressions of hyper-reactivity in MCS during whole-body exposure to low...... concentrations of the odorant n-butanol. Methods: We exposed 18 participants with MCS and 18 non-ill controls to a low concentration of the odorant n-butanol using an exposure chamber. The first 10 min constituted blank exposure, after which the n-butanol concentration increased and reached a plateau at 11.5 mg....../m3. Results: MCS participants, compared with controls, reported greater perceived odor intensities, more unpleasantness to the exposure and increasing symptoms over time. MCS participants also expressed higher pulse rate and lower pulse rate variability than controls did. No group differences were...

  6. The contact-temperature ignition (CTI) criteria for propagating chemical reactions including the effect of moisture and application to Hanford waste

    International Nuclear Information System (INIS)

    Cash, R.J.

    1995-01-01

    To assure the continued absence of uncontrolled condensed-phase chemical reactions in connection with the Hanford waste materials, efforts have been underway including both theoretical and experimental investigations to clarify the requirements for such reactions. This document defines the differences and requirements for homogeneous runaway and propagating chemical reactions incuding a discussion of general contact-temperature ignition (CTI) condition for propagating reactions that include the effect of moisture. The CTI condition implies that the contact temperature or interface temperature between reacted and unreacted materials must exceed the ignition temperature and is compared to experimental data including both synthetic ferrocyanide and surrogate organic materials. In all cases, the occurrences of ignition accompanied by self-propagating reactions are consistent with the theoretical anticipations of the CTI condition

  7. An improvement of LLNA:DA to assess the skin sensitization potential of chemicals.

    Science.gov (United States)

    Zhang, Hongwei; Shi, Ying; Wang, Chao; Zhao, Kangfeng; Zhang, Shaoping; Wei, Lan; Dong, Li; Gu, Wen; Xu, Yongjun; Ruan, Hongjie; Zhi, Hong; Yang, Xiaoyan

    2017-01-01

    We developed a modified local lymph node assay based on ATP (LLNA:DA), termed the Two-Stage LLNA:DA, to further reduce the animal numbers in the identification of sensitizers. In the Two-Stage LLNA:DA procedure, 13 chemicals ranging from non-sensitizers to extreme sensitizers were selected. The first stage used reduced LLNA:DA (rLLNA:DA) to screen out sensitive chemicals. The second stage used LLNA:DA based on OECD 442 (A) to classify those potential sensitizers screened out in the first stage. In the first stage, the SIs of the methyl methacrylate, salicylic acid, methyl salicylate, ethyl salicylate, isopropanol and propanediol were below 1.8 and need not to be tested in the second step. Others continued to be tested by LLNA:DA. In the second stage, sodium lauryl sulphate and xylene were classified as weak sensitizers. a-hexyl cinnamic aldehyde and eugenol were moderate sensitizers. Benzalkonium chloride and glyoxal were strong sensitizers, and phthalic anhydride was an extreme sensitizer. The 9/9, 11/12, 10/11, and 8/13 (positive or negative only) categories of the Two-Stage LLNA:DA were consistent with those from the other methods (LLNA, LLNA:DA, GPMT/BT and HMT/HPTA), suggesting that Two-Stage LLNA:DA have a high coincidence rate with reported data. In conclusion, The Two-Stage LLNA:DA is in line with the "3R" rules, and can be a modification of LLNA:DA but needs more study.

  8. Air-borne contact dermatitis due to Chrysanthemum with true cross sensitivity to Parthenium hysterophorus and Xanthium strumarium

    Directory of Open Access Journals (Sweden)

    Pasricha J

    1992-01-01

    Full Text Available A 60-year old man living in Srinagar (Jammu and Kashmir had air-borne contact dermatitis for last 10 years. He had never traveled to any other part of the country where Parthenium hysterophorus or Xanthium strumarium are prevalent but he used to cultivate chrysanthemums. Patch tests with standardized extracts of various plants revealed the strongest reaction with Chrysanthemum, while the reactions with Xanthium strumarium and Parthenium hysterophorus were also positive but milder. This seems to be a case of primary sensitivity to Chrysanthemum with cross sensitivity to Xanthium strumarium and Parthenium hysterophorus.

  9. Skin sensitization potency of methyl methacrylate in the local lymph node assay: comparisons with guinea-pig data and human experience.

    Science.gov (United States)

    Betts, Catherine J; Dearman, Rebecca J; Heylings, Jon R; Kimber, Ian; Basketter, David A

    2006-09-01

    There is compelling evidence that contact allergens differ substantially (by 4 or 5 orders of magnitude) with respect to their inherent skin-sensitizing potency. Relative potency can now be measured effectively using the mouse local lymph node assay (LLNA) and such data form the basis of risk assessment and risk management strategies. Such determinations also facilitate distinctions being drawn between the prevalence of skin sensitization to a particular contact allergen and inherent potency. The distinction is important because chemicals that are implicated as common causes of contact allergy are not necessarily potent sensitizers. One example is provided by nickel that is undoubtedly a common cause of allergic contact dermatitis, but is a comparatively weak sensitizer in predictive tests. In an attempt to explore other examples of contact allergens where there may exist a discrepancy between prevalence and potency, we describe here analyses conducted with methyl methacrylate (MMA). Results of LLNA studies have been interpreted in the context of historical clinical data on occupational allergic contact dermatitis associated with exposure to MMA.

  10. Scientific Challenges in the Risk Assessment of Food Contact Materials

    DEFF Research Database (Denmark)

    Muncke, Jane; Backhaus, Thomas; Geueke, Birgit

    2017-01-01

    formed in the production processes. Several factors hamper effective RA for many FCMs, including a lack of information on chemical identity, inadequate assessment of hazardous properties, and missing exposure data. Companies make decisions about the safety of some food contact chemicals (FCCs) without......Food contact articles (FCAs) are manufactured from food contact materials (FCMs) that include plastics, paper, metal, glass, and printing inks. Chemicals can migrate from FCAs into food during storage, processing, and transportation. Food contact materials' safety is evaluated using chemical risk...... to enhance the safety of food contact articles. Based on our evaluation of the evidence, we conclude that current regulations are insufficient for addressing chemical exposures from FCAs. RA currently focuses on monomers and additives used in the manufacture of products, but it does not cover all substances...

  11. PH Sensitive Polymers for Improving Reservoir Sweep and Conformance Control in Chemical Flooring

    Energy Technology Data Exchange (ETDEWEB)

    Mukul Sharma; Steven Bryant; Chun Huh

    2008-03-31

    There is an increasing opportunity to recover bypassed oil from depleted, mature oilfields in the US. The recovery factor in many reservoirs is low due to inefficient displacement of the oil by injected fluids (typically water). The use of chemical flooding methods to increase recovery efficiencies is severely constrained by the inability of the injected chemicals to contact the bypassed oil. Low sweep efficiencies are the primary cause of low oil recoveries observed in the field in chemical flooding operations even when lab studies indicate high oil recovery efficiency. Any technology that increases the ability of chemical flooding agents to better contact the remaining oil and reduce the amount of water produced in conjunction with the produced oil will have a significant impact on the cost of producing oil domestically in the US. This translates directly into additional economically recoverable reserves, which extends the economic lives of marginal and mature wells. The objective of this research project was to develop a low-cost, pH-triggered polymer for use in IOR processes to improve reservoir sweep efficiency and reservoir conformance in chemical flooding. Rheological measurements made on the polymer solution, clearly show that it has a low viscosity at low pH and exhibits a sudden increase in viscosity (by 2 orders of magnitude or more) at a pH of 3.5 to 4. This implies that the polymer would preferentially flow into zones containing water since the effective permeability to water is highest in these zones. As the pH of the zone increases due to the buffering capacity of the reservoir rock, the polymer solution undergoes a liquid to gel transition causing a sharp increase in the viscosity of the polymer solution in these zones. This allows operationally robust, in-depth conformance treatment of such water bearing zones and better mobility control. The rheological properties of HPAM solutions were measured. These include: steady-shear viscosity and

  12. Predicting chemically-induced skin reactions. Part I: QSAR models of skin sensitization and their application to identify potentially hazardous compounds

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Vinicius M. [Laboratory of Molecular Modeling and Design, Faculty of Pharmacy, Federal University of Goiás, Goiânia, GO 74605-220 (Brazil); Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States); Muratov, Eugene [Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States); Laboratory of Theoretical Chemistry, A.V. Bogatsky Physical-Chemical Institute NAS of Ukraine, Odessa 65080 (Ukraine); Fourches, Denis [Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States); Strickland, Judy; Kleinstreuer, Nicole [ILS/Contractor Supporting the NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM), P.O. Box 13501, Research Triangle Park, NC 27709 (United States); Andrade, Carolina H. [Laboratory of Molecular Modeling and Design, Faculty of Pharmacy, Federal University of Goiás, Goiânia, GO 74605-220 (Brazil); Tropsha, Alexander, E-mail: alex_tropsha@unc.edu [Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States)

    2015-04-15

    Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putative sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using Random Forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers was 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR Toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the Scorecard database of possible skin or sense organ toxicants as primary candidates for experimental validation. - Highlights: • It was compiled the largest publicly-available skin sensitization dataset. • Predictive QSAR models were developed for skin sensitization. • Developed models have higher prediction accuracy than OECD QSAR Toolbox. • Putative

  13. Predicting chemically-induced skin reactions. Part I: QSAR models of skin sensitization and their application to identify potentially hazardous compounds

    International Nuclear Information System (INIS)

    Alves, Vinicius M.; Muratov, Eugene; Fourches, Denis; Strickland, Judy; Kleinstreuer, Nicole; Andrade, Carolina H.; Tropsha, Alexander

    2015-01-01

    Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putative sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using Random Forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers was 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR Toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the Scorecard database of possible skin or sense organ toxicants as primary candidates for experimental validation. - Highlights: • It was compiled the largest publicly-available skin sensitization dataset. • Predictive QSAR models were developed for skin sensitization. • Developed models have higher prediction accuracy than OECD QSAR Toolbox. • Putative

  14. Patients with multiple contact allergies

    DEFF Research Database (Denmark)

    Carlsen, Berit Christina; Andersen, Klaus Ejner; Menné, Torkil

    2008-01-01

    Patients with multiple contact allergies, also referred to as polysensitized, are more frequent than predicted from prevalence of single sensitivities. The understanding of why some people develop multiple contact allergies, and characterization of patients with multiple contact allergies...... of developing multiple contact allergies. Evidence of allergen clusters among polysensitized individuals is also reviewed. The literature supports the idea that patients with multiple contact allergies constitute a special entity within the field of contact allergy. There is no generally accepted definition...... of patients with multiple contact allergies. We suggest that contact allergy to 3 or more allergens are defined as multiple contact allergies....

  15. Direct measurement of graphene contact resistivity to pre-deposited metal in buried contact test structure

    KAUST Repository

    Qaisi, Ramy M.; Smith, Casey; Ghoneim, Mohamed T.; Yu, Qingkai; Hussain, Muhammad Mustafa

    2013-01-01

    We demonstrate a buried contact based novel test structure for direct contact resistivity measurement of graphene-metal interfaces. We also observe excellent contact resistivity 1 μO-cm2 without any additional surface modification suggesting that the intrinsic Au-graphene contact is sufficient for achieving devices with low contact resistance. The chemical mechanical polishing less test structure and data described herein highlights an ideal methodology for systematic screening and engineering of graphene-metal contact resistivity to enable low power high speed carbon electronics. © 2013 IEEE.

  16. Direct measurement of graphene contact resistivity to pre-deposited metal in buried contact test structure

    KAUST Repository

    Qaisi, Ramy M.

    2013-08-01

    We demonstrate a buried contact based novel test structure for direct contact resistivity measurement of graphene-metal interfaces. We also observe excellent contact resistivity 1 μO-cm2 without any additional surface modification suggesting that the intrinsic Au-graphene contact is sufficient for achieving devices with low contact resistance. The chemical mechanical polishing less test structure and data described herein highlights an ideal methodology for systematic screening and engineering of graphene-metal contact resistivity to enable low power high speed carbon electronics. © 2013 IEEE.

  17. Electric contact arcing

    International Nuclear Information System (INIS)

    Cuthrell, R.E.

    1976-01-01

    Electrical contacts must function properly in many types of components used in nuclear weapon systems. Design, application, and testing of these components require detailed knowledge of chemical and physical phenomena associated with stockpile storage, stockpile testing, and operation. In the past, investigation of these phenomena has led to significant discoveries on the effects of surface contaminants, friction and wear, and the mechanics of closure on contact performance. A recent investigation of contact arcing phenomena which revealed that, preceding contact closure, arcs may occur at voltages lower than had been previously known is described. This discovery is important, since arcing may damage contacts, and repetitive testing of contacts performed as part of a quality assurance program might produce cumulative damage that would yield misleading life-test data and could prevent proper operation of the contacts at some time in the future. This damage can be avoided by determining the conditions under which arcing occurs, and ensuring that these conditions are avoided in contact testing

  18. Comparison of the sensitivities of the Buehler test and the guinea pig maximization test for predictive testing of contact allergy

    DEFF Research Database (Denmark)

    Frankild, S; Vølund, A; Wahlberg, J E

    2001-01-01

    International test guidelines, such as the Organisation for Economic Cooperation and Development (OECD) guideline #406, recommend 2 guinea pig methods for testing of the contact allergenic potential of chemicals: the Guinea Pig Maximization Test (GPMT) and the Buehler test. Previous comparisons...

  19. Occupations at risk of developing contact allergy to isothiazolinones in Danish contact dermatitis patients

    DEFF Research Database (Denmark)

    Schwensen, Jakob F; Menné, Torkil; Andersen, Klaus E

    2014-01-01

    , MCI/MI and BIT between 2009 and 2013 were included. RESULTS: MI contact allergy showed a significantly increased trend in prevalence from 1.8% in 2009 to 4.2% in 2012 (p dermatitis mainly drove the increase in 2012. Adjusted logistic regression analysis showed that MI...... sensitization was significantly associated with occupational exposures, hand and facial dermatitis, age > 40 years, and the occupational groups of tile setters/terrazzo workers, machine operators, and painters. MCI/MI contact allergy was significantly associated with the following high-risk occupations......BACKGROUND: In recent years, the prevalence of contact allergy to isothiazolinones has reached epidemic levels. Few studies have presented data on occupations at risk of developing contact allergy to isothiazolinones. OBJECTIVES: To present demographics and examine risk factors for sensitization...

  20. Schottky-contact plasmonic rectenna for biosensing

    Science.gov (United States)

    Alavirad, Mohammad; Siadat Mousavi, Saba; Roy, Langis; Berini, Pierre

    2013-10-01

    We propose a plasmonic gold nanodipole array on silicon, forming a Schottky contact thereon, and covered by water. The behavior of this array under normal excitation has been extensively investigated. Trends have been found and confirmed by identification of the mode propagating in nanodipoles and its properties. This device can be used to detect infrared radiation below the bandgap energy of the substrate via internal photoelectric effect (IPE). Also we estimate its responsivity and detection limit. Finally, we assess the potential of the structure for bulk and surface (bio) chemical sensing. Based on modal results an analytical model has been proposed to estimate the sensitivity of the device. Results show a good agreement between numerical and analytical interpretations.

  1. A TOUCH-SENSITIVE DEVICE

    DEFF Research Database (Denmark)

    2009-01-01

    The present invention relates to an optical touch-sensitive device and a method of determining a position and determining a position change of an object contacting an optical touch sensitive device. In particular, the present invention relates to an optical touch pad and a method of determining...... a position and determining a position change of an object contacting an optical touch pad. A touch-sensitive device, according to the present invention may comprise a light source, a touch- sensitive waveguide, a detector array, and a first light redirecting member, wherein at least a part of the light...... propagating towards a specific point of the detector array is prevented from being incident upon the specific point of the detector array when an object contacts a touch-sensitive surface of the touch-sensitive waveguide at a corresponding specific contact point....

  2. Predicting chemically-induced skin reactions. Part I: QSAR models of skin sensitization and their application to identify potentially hazardous compounds

    Science.gov (United States)

    Alves, Vinicius M.; Muratov, Eugene; Fourches, Denis; Strickland, Judy; Kleinstreuer, Nicole; Andrade, Carolina H.; Tropsha, Alexander

    2015-01-01

    Repetitive exposure to a chemical agent can induce an immune reaction in inherently susceptible individuals that leads to skin sensitization. Although many chemicals have been reported as skin sensitizers, there have been very few rigorously validated QSAR models with defined applicability domains (AD) that were developed using a large group of chemically diverse compounds. In this study, we have aimed to compile, curate, and integrate the largest publicly available dataset related to chemically-induced skin sensitization, use this data to generate rigorously validated and QSAR models for skin sensitization, and employ these models as a virtual screening tool for identifying putative sensitizers among environmental chemicals. We followed best practices for model building and validation implemented with our predictive QSAR workflow using random forest modeling technique in combination with SiRMS and Dragon descriptors. The Correct Classification Rate (CCR) for QSAR models discriminating sensitizers from non-sensitizers were 71–88% when evaluated on several external validation sets, within a broad AD, with positive (for sensitizers) and negative (for non-sensitizers) predicted rates of 85% and 79% respectively. When compared to the skin sensitization module included in the OECD QSAR toolbox as well as to the skin sensitization model in publicly available VEGA software, our models showed a significantly higher prediction accuracy for the same sets of external compounds as evaluated by Positive Predicted Rate, Negative Predicted Rate, and CCR. These models were applied to identify putative chemical hazards in the ScoreCard database of possible skin or sense organ toxicants as primary candidates for experimental validation. PMID:25560674

  3. Pediatric contact dermatitis

    Directory of Open Access Journals (Sweden)

    Sharma Vinod

    2010-01-01

    Full Text Available Allergic contact dermatitis (ACD in children, until recently, was considered rare. ACD was considered as a disorder of the adult population and children were thought to be spared due to a lack of exposure to potential allergens and an immature immune system. Prevalence of ACD to even the most common allergens in children, like poison ivy and parthenium, is relatively rare as compared to adults. However, there is now growing evidence of contact sensitization of the pediatric population, and it begins right from early childhood, including 1-week-old neonates. Vaccinations, piercing, topical medicaments and cosmetics in younger patients are potential exposures for sensitization. Nickel is the most common sensitizer in almost all studies pertaining to pediatric contact dermatitis. Other common allergens reported are cobalt, fragrance mix, rubber, lanolin, thiomersol, neomycin, gold, mercapto mix, balsum of Peru and colophony. Different factors like age, sex, atopy, social and cultural practices, habit of parents and caregivers and geographic changes affect the patterns of ACD and their variable clinical presentation. Patch testing should be considered not only in children with lesions of a morphology suggestive of ACD, but in any child with dermatitis that is difficult to control.

  4. A national population study of the prevalence of multiple chemical sensitivity.

    Science.gov (United States)

    Caress, Stanley M; Steinemann, Anne C

    2004-06-01

    The authors conducted a telephone survey of 1054 randomly selected individuals within the continental United States to determine the prevalence of chemical hypersensitivity and the medical diagnosis of multiple chemical sensitivity (MCS) in the American population. The etiology and symptomatology of MCS also were investigated. Results produced a 95% confidence level and a +/-3% margin of error. The authors found that 11.2% of Americans reported an unusual hypersensitivity to common chemical products such as perfume, fresh paint, pesticides, and other petrochemical-based substances, and 2.5% reported they had been medically diagnosed with MCS. Additionally, 31.1% of those sampled reported adverse reactions to fragranced products, and 17.6% experienced breathing difficulties and other health problems when exposed to air fresheners. Although chemical hypersensitivity was more common in women, it affected individuals in all demographic groups studied.

  5. Quantitative Genome-Wide Analysis of Yeast Deletion Strain Sensitivities to Oxidative and Chemical Stress

    Directory of Open Access Journals (Sweden)

    Stanley Fields

    2006-03-01

    Full Text Available Understanding the actions of drugs and toxins in a cell is of critical importance to medicine, yet many of the molecular events involved in chemical resistance are relatively uncharacterized. In order to identify the cellular processes and pathways targeted by chemicals, we took advantage of the haploid Saccharomyces cerevisiae deletion strains (Winzeler et al., 1999. Although ~4800 of the strains are viable, the loss of a gene in a pathway affected by a drug can lead to a synthetic lethal effect in which the combination of a deletion and a normally sublethal dose of a chemical results in loss of viability. WE carried out genome-wide screens to determine quantitative sensitivities of the deletion set to four chemicals: hydrogen peroxide, menadione, ibuprofen and mefloquine. Hydrogen peroxide and menadione induce oxidative stress in the cell, whereas ibuprofen and mefloquine are toxic to yeast by unknown mechanisms. Here we report the sensitivities of 659 deletion strains that are sensitive to one or more of these four compounds, including 163 multichemicalsensitive strains, 394 strains specific to hydrogen peroxide and/or menadione, 47 specific to ibuprofen and 55 specific to mefloquine.We correlate these results with data from other large-scale studies to yield novel insights into cellular function.

  6. High Sensitivity, Low Power Nano Sensors and Devices for Chemical Sensing

    Science.gov (United States)

    Li, Jing; Powell, Dan; Getty, Stephanie; Lu, Yi-Jiang

    2004-01-01

    The chemical sensor market has been projected to grow to better than $40 billion dollars worldwide within the next 10 years. Some of the primary motivations to develop nanostructured chemical sensors are monitoring and control of environmental pollution; improved diagnostics for consumption; improvement in measurement precision and accuracy; and improved detection limits for Homeland security, battlefield environments, and process and quality control of industrial applications. In each of these applications, there is demand for sensitivity, selectivity and stability of environmental and biohazard detection and capture beyond what is currently commercially available. Nanotechnology offers the ability to work at the molecular level, atom by atom, to create large structures with fundamentally new molecular organization. It is essentially concerned with materials, devices, and systems whose structures and components exhibit novel and significantly improved physical, chemical and biological properties, phenomena, and process control due to their nanoscale size. One such nanotechnology-enabled chemical sensor has been developed at NASA Ames leveraging nanostructures, such as single walled carbon nanotubes (SWNTs) and metal oxide nanobelts or nanowires, as a sensing medium bridging a pair of interdigitated electrodes (IDE) realized through a silicon-based microfabrication and micromachining technique. The DE fingers are fabricated on a silicon substrate using standard photolithography and thin film metallization techniques. It is noteworthy that the fabrication techniques employed are not confined to the silicon substrate. Through spin casting and careful substrate selection (i.e. clothing, glass, polymer, etc.), additional degrees of freedom can be exploited to enhance sensitivity or to conform to unique applications. Both in-situ growth of nanostructured materials and casting of nanostructured dispersions were used to produce analogous chemical sensing devices.

  7. Increased cell proliferation in spleen and lymph nodes peripheral to contact allergen application site

    International Nuclear Information System (INIS)

    Chipinda, Itai; Anderson, Stacey E.; Butterworth, Leon F.; Beezhold, Donald; Siegel, Paul D.

    2009-01-01

    The local lymph node assay (LLNA) is widely used to identify chemicals that are contact sensitizers. The assay involves dosing mice with the chemical on both ears and pooling the superficial parotid lymph nodes for assessment of lymphocyte proliferation as a marker of sensitization. The present study explored potential reduction in animal usage by dosing one ear with the allergen and the other with vehicle-only. The respective draining lymph nodes were processed separately for tritiated thymidine ( 3 H-TdR) incorporation. Cell proliferation in proper axillary and renal nodes, as well as in the spleen was also assessed. Cross-contamination of the chemicals from the dosed ears to other parts of the body via preening was prevented by dosing restrained animals and washing off the residual chemical with saline after 4 h. Dosing the left ear with 0.02% oxazolone (OX) on unrestrained animals resulted in marked cell proliferation in its draining lymph node (stimulation index, SI = 12.8) and in the lymph node draining the contra-lateral vehicle-dosed ear (SI = 6), as well as the proper axillary lymph nodes (SI = 3.3). Increased 3 H-TdR incorporation was not observed in the renal lymph nodes (SI = 1.1). Similar stimulation of cells was observed in the lymph node draining the ear contra-lateral to the 30% hexylcinnamaldehyde (HCA)-dosed ear. Increased proliferative activity was observed in contra-lateral draining lymph nodes of restrained mice demonstrating that these results cannot be attributed to cross-contamination of adjacent skin. A significant increase in proliferation of splenocytes was also observed. It is concluded that dermal application of a contact allergen, as exemplified by OX and HCA, may induce cell proliferation in the neighboring lymph nodes and spleen indicative of hapten and/or haptenated proteins diffusing through the skin to peripheral nodes and the blood to produce systemic sensitization. It is also possible that lymphatic capillaries may communicate

  8. Anchoring molecular mechanisms to the adverse outcome pathway for skin sensitization: Analysis of existing data

    NARCIS (Netherlands)

    Veen, J.W. van der; Soeteman-Hernández, L.G.; Ezendam, J.; Stierum, R.; Kuper, F.C.; Loveren, H. van

    2014-01-01

    Allergic contact dermatitis (ACD) is a hypersensitivity immune response induced by small protein-reactive chemicals. Currently, the murine local lymph node assay (LLNA) provides hazard identification and quantitative estimation of sensitizing potency. Given the complexity of ACD, a single

  9. Windows of sensitivity to toxic chemicals in the motor effects development.

    Science.gov (United States)

    Ingber, Susan Z; Pohl, Hana R

    2016-02-01

    Many chemicals currently used are known to elicit nervous system effects. In addition, approximately 2000 new chemicals introduced annually have not yet undergone neurotoxicity testing. This review concentrated on motor development effects associated with exposure to environmental neurotoxicants to help identify critical windows of exposure and begin to assess data needs based on a subset of chemicals thoroughly reviewed by the Agency for Toxic Substances and Disease Registry (ATSDR) in Toxicological Profiles and Addenda. Multiple windows of sensitivity were identified that differed based on the maturity level of the neurological system at the time of exposure, as well as dose and exposure duration. Similar but distinct windows were found for both motor activity (GD 8-17 [rats], GD 12-14 and PND 3-10 [mice]) and motor function performance (insufficient data for rats, GD 12-17 [mice]). Identifying specific windows of sensitivity in animal studies was hampered by study designs oriented towards detection of neurotoxicity that occurred at any time throughout the developmental process. In conclusion, while this investigation identified some critical exposure windows for motor development effects, it demonstrates a need for more acute duration exposure studies based on neurodevelopmental windows, particularly during the exposure periods identified in this review. Published by Elsevier Inc.

  10. Highly sensitive MoS2 photodetectors with graphene contacts

    Science.gov (United States)

    Han, Peize; St. Marie, Luke; Wang, Qing X.; Quirk, Nicholas; El Fatimy, Abdel; Ishigami, Masahiro; Barbara, Paola

    2018-05-01

    Two-dimensional materials such as graphene and transition metal dichalcogenides (TMDs) are ideal candidates to create ultra-thin electronics suitable for flexible substrates. Although optoelectronic devices based on TMDs have demonstrated remarkable performance, scalability is still a significant issue. Most devices are created using techniques that are not suitable for mass production, such as mechanical exfoliation of monolayer flakes and patterning by electron-beam lithography. Here we show that large-area MoS2 grown by chemical vapor deposition and patterned by photolithography yields highly sensitive photodetectors, with record shot-noise-limited detectivities of 8.7 × 1014 Jones in ambient condition and even higher when sealed with a protective layer. These detectivity values are higher than the highest values reported for photodetectors based on exfoliated MoS2. We study MoS2 devices with gold electrodes and graphene electrodes. The devices with graphene electrodes have a tunable band alignment and are especially attractive for scalable ultra-thin flexible optoelectronics.

  11. Contact stress sensor

    Science.gov (United States)

    Kotovsky, Jack [Oakland, CA

    2012-02-07

    A contact stress sensor includes one or more MEMS fabricated sensor elements, where each sensor element of includes a thin non-recessed portion, a recessed portion and a pressure sensitive element adjacent to the recessed portion. An electric circuit is connected to the pressure sensitive element. The circuit includes a thermal compensator and a pressure signal circuit element configured to provide a signal upon movement of the pressure sensitive element.

  12. Spectroscopic Chemical Analysis Methods and Apparatus

    Science.gov (United States)

    Hug, William F. (Inventor); Reid, Ray D. (Inventor); Bhartia, Rohit (Inventor); Lane, Arthur L. (Inventor)

    2018-01-01

    Spectroscopic chemical analysis methods and apparatus are disclosed which employ deep ultraviolet (e.g. in the 200 nm to 300 nm spectral range) electron beam pumped wide bandgap semiconductor lasers, incoherent wide bandgap semiconductor light emitting devices, and hollow cathode metal ion lasers to perform non-contact, non-invasive detection of unknown chemical analytes. These deep ultraviolet sources enable dramatic size, weight and power consumption reductions of chemical analysis instruments. In some embodiments, Raman spectroscopic detection methods and apparatus use ultra-narrow-band angle tuning filters, acousto-optic tuning filters, and temperature tuned filters to enable ultra-miniature analyzers for chemical identification. In some embodiments Raman analysis is conducted along with photoluminescence spectroscopy (i.e. fluorescence and/or phosphorescence spectroscopy) to provide high levels of sensitivity and specificity in the same instrument.

  13. Contact sensitization to fragrances in the general population: a Koch's approach may reveal the burden of disease

    DEFF Research Database (Denmark)

    Thyssen, J P; Menné, T; Linneberg, A

    2009-01-01

    subjects were tested in total. The median prevalence of FM and MP sensitization among adults was 2.3% (women, 1.7%; men, 1.3%) and 1.1% (women, 1.4%; men, 0%), respectively. CONCLUSIONS: Based on the reliability of patch test data from the general population and exposure data obtained from patients...... the prevalence of fragrance sensitization in the general population, and to suggest how future population-based studies and questionnaires should be constructed, better to assess the prevalence and burden of fragrance sensitization. This is of relevance as it is often difficult to establish causality...... in biological systems. METHODS: A systematic review of the literature was carried out by searching Pubmed-Medline, Biosis and contact dermatitis textbooks. RESULTS: Nineteen studies were identified, of which 13 were performed among adults. Sample sizes varied between 82 and 2545 tested subjects, and 11 648...

  14. Contacts to semiconductors

    International Nuclear Information System (INIS)

    Tove, P.A.

    1975-08-01

    Contacts to semiconductors play an important role in most semiconductor devices. These devices range from microelectronics to power components, from high-sensitivity light or radiation detectors to light-emitting of microwave-generating components. Silicon is the dominating material but compound semiconductors are increasing in importance. The following survey is an attempt to classify contact properties and the physical mechanisms involved, as well as fabrication methods and methods of investigation. The main interest is in metal-semiconductor type contacts where a few basic concepts are dealt with in some detail. (Auth.)

  15. Chemical kinetic functional sensitivity analysis: Elementary sensitivities

    International Nuclear Information System (INIS)

    Demiralp, M.; Rabitz, H.

    1981-01-01

    Sensitivity analysis is considered for kinetics problems defined in the space--time domain. This extends an earlier temporal Green's function method to handle calculations of elementary functional sensitivities deltau/sub i//deltaα/sub j/ where u/sub i/ is the ith species concentration and α/sub j/ is the jth system parameter. The system parameters include rate constants, diffusion coefficients, initial conditions, boundary conditions, or any other well-defined variables in the kinetic equations. These parameters are generally considered to be functions of position and/or time. Derivation of the governing equations for the sensitivities and the Green's funciton are presented. The physical interpretation of the Green's function and sensitivities is given along with a discussion of the relation of this work to earlier research

  16. Predicting the sensitivity of populations from individual exposure to chemicals: the role of ecological interactions.

    Science.gov (United States)

    Gabsi, Faten; Schäffer, Andreas; Preuss, Thomas G

    2014-07-01

    Population responses to chemical stress exposure are influenced by nonchemical, environmental processes such as species interactions. A realistic quantification of chemical toxicity to populations calls for the use of methodologies that integrate these multiple stress effects. The authors used an individual-based model for Daphnia magna as a virtual laboratory to determine the influence of ecological interactions on population sensitivity to chemicals with different modes of action on individuals. In the model, hypothetical chemical toxicity targeted different vital individual-level processes: reproduction, survival, feeding rate, or somatic growth rate. As for species interactions, predatory and competition effects on daphnid populations were implemented following a worst-case approach. The population abundance was simulated at different food levels and exposure scenarios, assuming exposure to chemical stress solely or in combination with either competition or predation. The chemical always targeted one vital endpoint. Equal toxicity-inhibition levels differently affected the population abundance with and without species interactions. In addition, population responses to chemicals were highly sensitive to the environmental stressor (predator or competitor) and to the food level. Results show that population resilience cannot be attributed to chemical stress only. Accounting for the relevant ecological interactions would reduce uncertainties when extrapolating effects of chemicals from individuals to the population level. Validated population models should be used for a more realistic risk assessment of chemicals. © 2014 SETAC.

  17. RubBer Contact Dermatitis in patients attended at Walter Cantídio Hospital, Federal University of Ceará, Brasil

    Directory of Open Access Journals (Sweden)

    DIÓGENES Maria José N.

    1998-01-01

    Full Text Available Nowadays 70% of the world's rubber supply is synthesized artificially. The process involved in its manufacture is vulcanization which requires many chemical substances for speeding the process, as antioxidants to prevent deterioration of rubber, or others. These substances may constitute important sensitizers and thus be responsible for dermatological diseases like contact dermatitis. The objective of this study is to search for the main sensitizers among these rubber chemicals in a population mostly composed by women of a tropical country and compare the results with the ones obtained from previous studies which tested populations mainly composed by men and on different climates.

  18. Systemic contact dermatitis after oral exposure to nickel

    DEFF Research Database (Denmark)

    Jensen, Christian Stab; Menné, Torkil; Johansen, Jeanne Duus

    2006-01-01

    Systemic contact dermatitis can be elicited experimentally in nickel-sensitive individuals by oral nickel exposure. A crucial point interpreting such experiments has been the relevance of nickel exposure from drinking water and diet. The aim of this meta-analysis study on former nickel......-exposure investigations was to provide the best possible estimation of threshold values of nickel doses that may cause systemic contact dermatitis in nickel-sensitive patients. 17 relevant investigations were identified, and statistical analyses were performed in a stepwise procedure. 9 studies were included in the final...... of the doses that, theoretically, would cause systemic contact dermatitis in exposed nickel-sensitive patients. The results from the 2 most sensitive groups show that 1% of these individuals may react with systemic contact dermatitis at normal daily nickel exposure from drinking water and diet, i.e. 0...

  19. Optical properties of photodetectors based on single GaN nanowires with a transparent graphene contact

    Energy Technology Data Exchange (ETDEWEB)

    Babichev, A. V., E-mail: A.Babichev@mail.ioffe.ru [Russian Academy of Sciences, Ioffe Institute (Russian Federation); Zhang, H.; Guan, N. [University Paris Saclay, Institut d’Electronique Fondamentale, UMR 8622 CNRS (France); Egorov, A. Yu. [ITMO University (Russian Federation); Julien, F. H.; Messanvi, A. [University Paris Saclay, Institut d’Electronique Fondamentale, UMR 8622 CNRS (France); Durand, C.; Eymery, J. [University Grenoble Alpes (France); Tchernycheva, M. [University Paris Saclay, Institut d’Electronique Fondamentale, UMR 8622 CNRS (France)

    2016-08-15

    We report the fabrication and optical and electrical characterization of photodetectors for the UV spectral range based on single p–n junction nanowires with a transparent contact of a new type. The contact is based on CVD-grown (chemical-vapor deposition) graphene. The active region of the nitride nanowires contains a set of 30 radial In{sub 0.18}Ga{sub 0.82}N/GaN quantum wells. The structure is grown by metal-organic vaporphase epitaxy. The photodetectors are fabricated using electron-beam lithography. The current–voltage characteristics exhibit a rectifying behavior. The spectral sensitivity of the photodetector is recorded starting from 3 eV and extending far in the UV range. The maximal photoresponse is observed at a wavelength of 367 nm (sensitivity 1.9 mA/W). The response switching time of the photodetector is less than 0.1 s.

  20. [News on occupational contact dermatitis].

    Science.gov (United States)

    Crépy, Marie-Noëlle; Bensefa-Colas, Lynda

    2014-03-01

    Contact dermatitis--irritant contact dermatitis, allergic contact dermatitis and protein contact dermatitis--are the most common occupational skin diseases, most often localized to the hands. Contact urticaria is rarer The main occupational irritants are wet work, detergents and disinfectants, cutting oils, and solvents. The main occupational allergens are rubber additives, metals (chromium, nickel, cobalt), plastics (epoxy resins, acrylic), biocides and plants. Diagnosis is based on clinical examination, medical history and allergy testing. For a number of irritating or sensitizing agents, irritant or allergic dermatitis can be notified as occupational diseases. The two main prevention measures are reducing skin contact with irritants and complete avoidance of skin contact with offending allergens.

  1. Mass loss and chemical structures of wheat and maize straws in response to ultraviolet-B radiation and soil contact

    Science.gov (United States)

    Zhou, Guixiang; Zhang, Jiabao; Mao, Jingdong; Zhang, Congzhi; Chen, Lin; Xin, Xiuli; Zhao, Bingzi

    2015-01-01

    The role of photodegradation, an abiotic process, has been largely overlooked during straw decomposition in mesic ecosystems. We investigated the mass loss and chemical structures of straw decomposition in response to elevated UV-B radiation with or without soil contact over a 12-month litterbag experiment. Wheat and maize straw samples with and without soil contact were exposed to three radiation levels: a no-sunlight control, ambient solar UV-B, and artificially elevated UV-B radiation. A block control with soil contact was not included. Compared with the no-sunlight control, UV-B radiation increased the mass loss by 14–19% and the ambient radiation by 9–16% for wheat and maize straws without soil contact after 12 months. Elevated UV-B exposure decreased the decomposition rates of both wheat and maize straws when in contact with soil. Light exposure resulted in decreased O-alkyl carbons and increased alkyl carbons for both the wheat and maize straws compared with no-sunlight control. The difference in soil contact may influence the contribution of photodegradation to the overall straw decomposition process. These results indicate that we must take into account the effects of photodegradation when explaining the mechanisms of straw decomposition in mesic ecosystems. PMID:26423726

  2. Mass loss and chemical structures of wheat and maize straws in response to ultraviolet-B radiation and soil contact.

    Science.gov (United States)

    Zhou, Guixiang; Zhang, Jiabao; Mao, Jingdong; Zhang, Congzhi; Chen, Lin; Xin, Xiuli; Zhao, Bingzi

    2015-10-01

    The role of photodegradation, an abiotic process, has been largely overlooked during straw decomposition in mesic ecosystems. We investigated the mass loss and chemical structures of straw decomposition in response to elevated UV-B radiation with or without soil contact over a 12-month litterbag experiment. Wheat and maize straw samples with and without soil contact were exposed to three radiation levels: a no-sunlight control, ambient solar UV-B, and artificially elevated UV-B radiation. A block control with soil contact was not included. Compared with the no-sunlight control, UV-B radiation increased the mass loss by 14-19% and the ambient radiation by 9-16% for wheat and maize straws without soil contact after 12 months. Elevated UV-B exposure decreased the decomposition rates of both wheat and maize straws when in contact with soil. Light exposure resulted in decreased O-alkyl carbons and increased alkyl carbons for both the wheat and maize straws compared with no-sunlight control. The difference in soil contact may influence the contribution of photodegradation to the overall straw decomposition process. These results indicate that we must take into account the effects of photodegradation when explaining the mechanisms of straw decomposition in mesic ecosystems.

  3. Fragrance contact allergy: a clinical review.

    Science.gov (United States)

    Johansen, Jeanne D

    2003-01-01

    Most people in modern society are exposed daily to fragrance ingredients from one or more sources. Fragrance ingredients are also one of the most frequent causes of contact allergic reactions. The diagnosis is made by patch testing with a mixture of fragrance ingredients, the fragrance mix. This gives a positive patch-test reaction in about 10% of tested patients with eczema, and the most recent estimates show that 1.7-4.1% of the general population are sensitized to ingredients of the fragrance mix. Fragrance allergy occurs predominantly in women with facial or hand eczema. These women typically have a history of rash to a fine fragrance or scented deodorants. Chemical analysis has revealed that well known allergens from the fragrance mix are present in 15-100% of cosmetic products, including deodorants and fine fragrances, and most often in combinations of three to four allergens in the same products. This means that it is difficult to avoid exposure, as products labelled as 'fragrance free' have also been shown to contain fragrance ingredients, either because of the use of fragrance ingredients as preservatives or masking perfumes, or the use of botanicals. About 2500 different fragrance ingredients are currently used in the composition of perfumes and at least 100 of these are known contact allergens. Therefore, it is advisable to supplement standard patch testing with the patient's own stay-on cosmetic products, as well as the fragrance chemical hydroxyisohexyl-3-cyclohexane carboxaldehyde, which on its own gives responses in 1-3% of tested patients. The focus in recent years on the ingredients of the fragrance mix will probably result in the fragrance industry changing the composition of perfumes, and thus make the current diagnostic test less useful. New diagnostic tests are under development to identify contact allergy to new allergens, reflecting the continuous developments and trends in exposure.

  4. Contact allergy to common ingredients in hair dyes

    DEFF Research Database (Denmark)

    Søsted, Heidi; Rustemeyer, Thomas; Gonçalo, Margarida

    2013-01-01

    p-Phenylenediamine (PPD) is the primary patch test screening agent for hair dye contact allergy, and approximately 100 different hair dye chemicals are allowed.......p-Phenylenediamine (PPD) is the primary patch test screening agent for hair dye contact allergy, and approximately 100 different hair dye chemicals are allowed....

  5. Endocrine disrupting chemicals and other substances of concern in food contact materials: an updated review of exposure, effect and risk assessment.

    Science.gov (United States)

    Muncke, Jane

    2011-10-01

    Food contact materials (FCM) are an underestimated source of chemical food contaminants and a potentially relevant route of human exposure to endocrine disrupting chemicals (EDCs). Quantifying the exposure of the general population to substances from FCM relies on estimates of food consumption and leaching into food. Recent studies using polycarbonate plastics show that food simulants do not always predict worst-case leaching of bisphenol A, a common FCM substance. Also, exposure of children to FCM substances is not always realistically predicted using the common conventions and thus possibly misjudged. Further, the exposure of the whole population to substances leaching into dry foods is underestimated. Consumers are exposed to low levels of substances from FCM across their entire lives. Effects of these compounds currently are assessed with a focus on mutagenicity and genotoxicity. This approach however neglects integrating recent new toxicological findings, like endocrine disruption, mixture toxicity, and developmental toxicity. According to these new toxicology paradigms women of childbearing age and during pregnancy are a new sensitive population group requiring more attention. Furthermore, in overweight and obese persons a change in the metabolism of xenobiotics is observed, possibly implying that this group of consumers is insufficiently protected by current risk assessment practice. Innovations in FCM risk assessment should therefore include routine testing for EDCs and an assessment of the whole migrate toxicity of a food packaging, taking into account all sensitive population groups. In this article I focus on recent issues of interest concerning either exposure to or effects of FCM-related substances. Further, I review the use of benzophenones and organotins, two groups of known or suspected EDCs, in FCM authorized in the US and EU. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. The impact of vehicle on the relative potency of skin-sensitizing chemicals in the local lymph node assay.

    Science.gov (United States)

    Jowsey, Ian R; Clapp, Catherine J; Safford, Bob; Gibbons, Ben T; Basketter, David A

    2008-01-01

    The identification and characterization of chemicals that possess skin-sensitizing potential are typically performed using predictive tests. However, human exposure to skin-sensitizing chemicals often occurs via a matrix (vehicle) that differs from that used in these tests. It is thus important to account for the potential impact of vehicle differences when undertaking quantitative risk assessment for skin sensitization. This is achieved through the application of a specific sensitization assessment factor (SAF), scaled between 1 and 10, when identifying an acceptable exposure level. The objective of the analysis described herein is to determine the impact of vehicle differences on local lymph node assay (LLNA) EC3 values (concentrations of test chemical required to provoke a 3-fold increase in lymph node cell proliferation). Initially, the inherent variability of the LLNA was investigated by examining the reproducibility of EC3 values for 14 chemicals that have been tested more than once in the same vehicle (4:1 acetone:olive oil, AOO). This analysis reveals that the variability in EC3 value for these chemicals following multiple assessments is LLNA using at least 2 of 15 different vehicles. These data demonstrate that often the variability in EC3 values observed for a given chemical in different vehicles is no greater than the 5-fold inherent variability observed when assessing a chemical in the same vehicle on multiple occasions. However, there are examples where EC3 values for a chemical differ by a factor of more than 10 between different vehicles. These observations were often associated with an apparent underestimation of potency (higher EC3 values) with predominantly aqueous vehicles or propylene glycol. These data underscore the need to consider vehicle effects in the context of skin-sensitization risk assessments.

  7. A STUDY ON CONTACT DERMATITIS TO HAIR DYE AND HENNA

    Directory of Open Access Journals (Sweden)

    Neerja Puri

    2013-10-01

    Full Text Available P- Phenylenediamine is an oxidative chemical that is frequently used as a permanent hair-coloring agent. It is added to henna to increase the intensity and longevity of the tattoo and expedites its drying time. Henna itself is a greenish brown vegetable coloring made from the leaves of Lawsonia inermis and rarely causes allergic contact dermatitis. The addition of PPD causes the contact sensitization to black henna. Serious adverse skin reactions to permanent hair dyes and temporary black tattoos have been reported. As temporary tattoos have become fashionable among adolescents, the risk profile for p-phenylenediamine (PPD sensitization of the population has changed simultaneously with an increasing use of hair dyes in this age group. With increased popularity of body art such as body piercing and tattooing, an increase in temporary henna tattoos has also occurred. Although the appeal of non-permanence exists for henna tattoos, dermatologists have begun to see numerous cases of allergic contact dermatitis linked with a certain type of henna. We selected 50 patients using hair dye and henna for our study. Patch testing was done in all the patients using Indian standard series of antigens. Regarding to the side effects to hair dye and henna and itching was the commonest symptom seen in 16% patients, erythematous scaly plaques were seen in 10% patients, vesicular reactions were seen in 6% patients, angioneurotic oedema and contact urticaria was seen in 4% patients each and anaphylaxis and keloidal reaction was seen in 2% patients each.

  8. Chemical-exchange-sensitive MRI of amide, amine and NOE at 9.4 T versus 15.2 T.

    Science.gov (United States)

    Chung, Julius Juhyun; Choi, Wonmin; Jin, Tao; Lee, Jung Hee; Kim, Seong-Gi

    2017-09-01

    Chemical exchange (CE)-sensitive MRI benefits greatly from stronger magnetic fields; however, field effects on CE-sensitive imaging have not yet been studied well in vivo. We have compared CE-sensitive Z-spectra and maps obtained at the fields of 9.4 T and 15.2 T in phantoms and rats with off-resonance chemical-exchange-sensitive spin lock (CESL), which is similar to conventional chemical exchange saturation transfer. At higher fields, the background peak at water resonance has less spread and the exchange rate relative to chemical shift decreases, thus CESL intensity is dependent on B 0 . For the in vivo amide and nuclear Overhauser enhancement (NOE) composite resonances of rat brains, intensities were similar for both magnetic fields, but effective amide proton transfer and NOE values obtained with three-point quantification or a curve fitting method were larger at 15.2 T due to the reduced spread of attenuation at the direct water resonance. When using intermediate exchange-sensitive irradiation parameters, the amine proton signal was 65% higher at 15.2 T than at 9.4 T due to a reduced ratio of exchange rate to chemical shift. In summary, increasing magnetic field provides enhancements to CE-sensitive signals in the intermediate exchange regime and reduces contamination from background signals in the slow exchange regime. Consequently, ultrahigh magnetic field is advantageous for CE-sensitive MRI, especially for amine and hydroxyl protons. Copyright © 2017 John Wiley & Sons, Ltd.

  9. Chemical exchange-sensitive spin-lock MRI of glucose analog 3-O-methyl-d-glucose in normal and ischemic brain.

    Science.gov (United States)

    Jin, Tao; Mehrens, Hunter; Wang, Ping; Kim, Seong-Gi

    2018-05-01

    Glucose transport is important for understanding brain glucose metabolism. We studied glucose transport with a presumably non-toxic and non-metabolizable glucose analog, 3-O-methyl-d-glucose, using a chemical exchange-sensitive spin-lock MRI technique at 9.4 Tesla. 3-O-methyl-d-glucose showed comparable chemical exchange properties with d-glucose and 2-deoxy-d-glucose in phantoms, and higher and lower chemical exchange-sensitive spin-lock sensitivity than Glc and 2-deoxy-d-glucose in in vivo experiments, respectively. The changes of the spin-lattice relaxation rate in the rotating frame (Δ R 1 ρ) in normal rat brain peaked at ∼15 min after the intravenous injection of 1 g/kg 3-O-methyl-d-glucose and almost maintained a plateau for >1 h. Doses up to 4 g/kg 3-O-methyl-d-glucose were linearly correlated with Δ R 1 ρ. In rats with focal ischemic stroke, chemical exchange-sensitive spin-lock with 3-O-methyl-d-glucose injection at 1 h after stroke onset showed reduced Δ R 1 ρ in the ischemic core but higher Δ R 1 ρ in the peri-core region compared to normal tissue, which progressed into the ischemic core at 3 h after stroke onset. This suggests that the hyper-chemical exchange-sensitive spin-lock region observed at 1 h is the ischemic penumbra at-risk of infarct. In summary, 3-O-methyl-d-glucose-chemical exchange-sensitive spin-lock can be a sensitive MRI technique to probe the glucose transport in normal and ischemic brains.

  10. Comparative toxicity of chemicals to earthworms

    Energy Technology Data Exchange (ETDEWEB)

    Callahan, C.A.; Shirazi, M.A. (Environmental Protection Agency, Corvallis, OR (United States)); Neuhauser, E.F. (Niagara Mohawk Power Corp., Syracuse, NY (United States))

    1994-02-01

    The concentration-response (mortality) relationships of four species of earthworms, Eisenia fetida (Savigny), Allolobophora tuberculata (Eisen), Eudrilus eugeniae (Kinberg), and Perionyx excavatus (Perrier) are summarized for 62 chemicals and two test protocols. A Weibull function is used to summarize these data for each chemical in terms of sensitivity and toxicity, in addition to the LC50. The estimation of the Weibull parameters a and k summarize the entire concentration-response relationship. This technique should be applicable to a variety of testing protocols with different species whenever the goal is summarizing the shape of the concentration-response curves to fully evaluate chemical impact on organisms. In some cases for these data four orders of magnitude separate LC50s of the soil test and the contact test for the same chemical and species. All four species appear to be similar in range of toxicity and tolerance to these chemicals, suggesting that Eisenia fetida and may be representative of these four species and these chemicals.

  11. Contact lens surface by electron beam

    International Nuclear Information System (INIS)

    Shin, Jung Hyuck; Lee, Suk Ju; Hwang, Kwang Ha; Jeon Jin

    2011-01-01

    Contact lens materials needs good biocompatibility, high refractive index, high optical transparency, high water content etc. Surface treat method by using plasma and radiation can modify the physical and/or chemical properties of the contact lens surface. Radiation technology such as electron beam irradiation can apply to polymerization reaction and enhance the functionality of the polymer.The purpose of this study is to modify of contact lens surface by using Eb irradiation technology. Electron beam was irradiated to the contact lens surface which was synthesized thermal polymerization method and commercial contact lens to modify physical and chemical properties. Ft-IR, XP, UV-vis spectrophotometer, water content, oxygen trans-metastability were used to characterize the surface state, physicochemical, and optical property of the contact lens treated with Eb. The water content and oxygen transmissibility of the contact lens treated with Eb were increased due to increase in the hydrophilic group such as O-C=O and OH group on the contact lens surface which could be produced by possible reaction between carbon and oxygen during the Eb irradiation. All of the lenses showed the high optical transmittance above 90%. In this case of B/Es, TES, Ti contact lens, the optical transmittance decreased about 5% with increasing Eb dose in the wavelength of UV-B region. The contact lens modified by Eb irradiation could improve the physical properties of the contact lens such as water content and oxygen transmissibility

  12. Contact dermatitis caused by tulips: identification of contact sensitizers in tulip workers of Kashmir Valley in North India.

    Science.gov (United States)

    Hassan, Iffat; Rasool, Farhan; Akhtar, Saniya; Kamili, Afifa; Rather, Parvaiz; Kanth, Raihana; Bhat, Yasmeen; Rather, Shagufta; Mubashir, Syed; Yaseen, Atiya; Bashir, Safia

    2018-01-01

    Tulip, belonging to the genus Tulipa and family Liliaceae, is a spring-blooming perennial that grows from bulbs. Owing to manual handling, contact dermatitis can occur in professionals at any stage of the growth cycle of the tulip plant. To determine the clinical pattern of contact dermatitis resulting from tulip plant cultivation, and to assess contact allergy in workers coming into contact with this plant. One hundred and sixty-four tulip workers were screened, and 48 patients with suspected contact dermatitis were patch tested with 39 allergens, including haptens from the Indian baseline series, a plant series, and extracts from different parts of the tulip plant. Thirty-nine positive patch test reactions were observed in 21 patients. Seventeen patients showed positive reactions to either α-methylene-γ-butyrolactone or to tulip plant extract. Clinical relevance was observed for 13 of 17 positive patch test reactions. Contact dermatitis is an important health hazard in workers dealing with tulip bulbs. Further studies to identify and isolate other possible tulip allergens, and to quantify the amounts of allergens in different parts of the tulip plant, are recommended. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Large-Area Chemical Vapor Deposited MoS2 with Transparent Conducting Oxide Contacts toward Fully Transparent 2D Electronics

    KAUST Repository

    Dai, Zhenyu

    2017-09-08

    2D semiconductors are poised to revolutionize the future of electronics and photonics, much like transparent oxide conductors and semiconductors have revolutionized the display industry. Herein, these two types of materials are combined to realize fully transparent 2D electronic devices and circuits. Specifically, a large-area chemical vapor deposition process is developed to grow monolayer MoS2 continuous films, which are, for the first time, combined with transparent conducting oxide (TCO) contacts. Transparent conducting aluminum doped zinc oxide contacts are deposited by atomic layer deposition, with composition tuning to achieve optimal conductivity and band-offsets with MoS2. The optimized process gives fully transparent TCO/MoS2 2D electronics with average visible-range transmittance of 85%. The transistors show high mobility (4.2 cm2 V−1 s−1), fast switching speed (0.114 V dec−1), very low threshold voltage (0.69 V), and large switching ratio (4 × 108). To our knowledge, these are the lowest threshold voltage and subthreshold swing values reported for monolayer chemical vapor deposition MoS2 transistors. The transparent inverters show fast switching properties with a gain of 155 at a supply voltage of 10 V. The results demonstrate that transparent conducting oxides can be used as contact materials for 2D semiconductors, which opens new possibilities in 2D electronic and photonic applications.

  14. Contact dermatitis in saffron workers: clinical profile and identification of contact sensitizers in a saffron-cultivating area of Kashmir Valley of North India.

    Science.gov (United States)

    Hassan, Iffat; Kamili, Afifa; Rasool, Farhan; Nehvi, Firdous; Rather, Parvaiz; Yasmin, Salwee; Pampori, Rafiq A; Jabeen, Yasmeen; Yaseen, Atiya; Bashir, Safia; Naaz, Saima

    2015-01-01

    Saffron, a bulbous perennial plant belonging to Iridaceae family, is the most expensive cultivated herb that is widely used for industrial and nonindustrial purposes. However, besides its attractive and valuable properties, contact dermatitis due to saffron is an uncommon reported entity. The aims of this study were to determine the clinical pattern patch-testing profile of contact dermatitis in saffron workers and to identify the most common allergens/sensitizers. One hundred ten saffron workers were patch-tested with 39 allergens, which included Indian standard series antigens, plant series antigens, and extracts from different parts of saffron flower. The allergens in Indian standard series accounted for 52.44% of positive reactions. Plant series and different parts of saffron accounted for 47.56% of the positive reactions. Among those patients with positive responses to the supplemental saffron allergens, 83.3% were of present or past relevance. The data observed in the present study confirm that the saffron dermatitis is a distinct clinical entity with characteristic clinical presentation and has a strong significance as an occupational allergen in those handling this plant. Patch testing with different parts of saffron flower has a role to play in finding out the etiological cause.

  15. The modified Cassie’s equation and contact angle hysteresis

    KAUST Repository

    Xu, Xianmin; Wang, Xiaoping

    2012-01-01

    In this paper, we derive a modified Cassie's equation for wetting on chemically patterned surfaces from a homogenization approach. The derivation reveals that effective contact angle is a local average of the static contact angle along the contact line which describes all possible equilibrium states including the local minimum of the free energy of the system. The usual Cassie's state which corresponds to the global minimum is only a special case. We then discuss the contact angle hysteresis on chemically patterned surfaces. © 2012 Springer-Verlag.

  16. Chemical allergens stimulate human epidermal keratinocytes to produce lymphangiogenic vascular endothelial growth factor.

    Science.gov (United States)

    Bae, Ok-Nam; Ahn, Seyeon; Jin, Sun Hee; Hong, Soo Hyun; Lee, Jinyoung; Kim, Eun-Sun; Jeong, Tae Cheon; Chun, Young-Jin; Lee, Ai-Young; Noh, Minsoo

    2015-03-01

    Allergic contact dermatitis (ACD) is a cell-mediated immune response that involves skin sensitization in response to contact with various allergens. Angiogenesis and lymphangiogenesis both play roles in the allergic sensitization process. Epidermal keratinocytes can produce vascular endothelial growth factor (VEGF) in response to UV irradiation and during wound healing. However, the effect of haptenic chemical allergens on the VEGF production of human keratinocytes, which is the primary contact site of toxic allergens, has not been thoroughly researched. We systematically investigated whether immune-regulatory cytokines and chemical allergens would lead to the production of VEGF in normal human keratinocytes (NHKs) in culture. VEGF production significantly increased when NHKs were treated with IFNγ, IL-1α, IL-4, IL-6, IL-17A, IL-22 or TNFα. Among the human sensitizers listed in the OECD Test Guideline (TG) 429, we found that CMI/MI, DNCB, 4-phenylenediamine, cobalt chloride, 2-mercaptobenzothiazole, citral, HCA, cinnamic alcohol, imidazolidinyl urea and nickel chloride all significantly upregulated VEGF production in NHKs. In addition, common human haptenic allergens such as avobenzone, formaldehyde and urushiol, also induced the keratinocyte-derived VEGF production. VEGF upregulation by pro-inflammatory stimuli, IFNγ, DNCB or formaldehyde is preceded by the production of IL-8, an acute inflammatory phase cytokine. Lymphangiogenic VEGF-C gene transcription was significantly increased when NHKs were treated with formaldehyde, DNCB or urushiol, while transcription of VEGF-A and VEGF-B did not change. Therefore, the chemical allergen-induced VEGF upregulation is mainly due to the increase in lymphangiogenic VEGF-C transcription in NHKs. These results suggest that keratinocyte-derived VEGF may regulate the lymphangiogenic process during the skin sensitization process of ACD. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Self-powered, ultra-sensitive, flexible tactile sensors based on contact electrification

    Science.gov (United States)

    Wang, Zhong Lin; Zhu, Guang

    2018-03-20

    A tactile sensor for sensing touch from a human finger includes a triboelectric layer and includes a material that becomes electrically charged after being in contact with the finger. The first side of a first conductive layer is in contact with the second side of triboelectric layer. The first side of a dielectric layer is in contact with the first conductive layer and the second side of the dielectric layer is in contact with a second conductive layer. When the triboelectric layer becomes electrically charged after being in contact with the finger, the first conductive layer and the second conductive layer are subjected to an electric field, which has a first field strength at the first conductive layer and a second field strength, different from the first field strength, at the second conductive layer. A plurality of tactile sensors can be arranged as a keyboard.

  18. The modified Cassie’s equation and contact angle hysteresis

    KAUST Repository

    Xu, Xianmin

    2012-08-29

    In this paper, we derive a modified Cassie\\'s equation for wetting on chemically patterned surfaces from a homogenization approach. The derivation reveals that effective contact angle is a local average of the static contact angle along the contact line which describes all possible equilibrium states including the local minimum of the free energy of the system. The usual Cassie\\'s state which corresponds to the global minimum is only a special case. We then discuss the contact angle hysteresis on chemically patterned surfaces. © 2012 Springer-Verlag.

  19. Cytochrome P450-mediated activation of the fragrance compound geraniol forms potent contact allergens

    International Nuclear Information System (INIS)

    Hagvall, Lina; Baron, Jens Malte; Boerje, Anna; Weidolf, Lars; Merk, Hans; Karlberg, Ann-Therese

    2008-01-01

    Contact sensitization is caused by low molecular weight compounds which penetrate the skin and bind to protein. In many cases, these compounds are activated to reactive species, either by autoxidation on exposure to air or by metabolic activation in the skin. Geraniol, a widely used fragrance chemical, is considered to be a weak allergen, although its chemical structure does not indicate it to be a contact sensitizer. We have shown that geraniol autoxidizes and forms allergenic oxidation products. In the literature, it is suggested but not shown that geraniol could be metabolically activated to geranial. Previously, a skin-like CYP cocktail consisting of cutaneous CYP isoenzymes, was developed as a model system to study cutaneous metabolism. In the present study, we used this system to investigate CYP-mediated activation of geraniol. In incubations with the skin-like CYP cocktail, geranial, neral, 2,3-epoxygeraniol, 6,7-epoxygeraniol and 6,7-epoxygeranial were identified. Geranial was the main metabolite formed followed by 6,7-epoxygeraniol. The allergenic activities of the identified metabolites were determined in the murine local lymph node assay (LLNA). Geranial, neral and 6,7-epoxygeraniol were shown to be moderate sensitizers, and 6,7-epoxygeranial a strong sensitizer. Of the isoenzymes studied, CYP2B6, CYP1A1 and CYP3A5 showed high activities. It is likely that CYP1A1 and CYP3A5 are mainly responsible for the metabolic activation of geraniol in the skin, as they are expressed constitutively at significantly higher levels than CYP2B6. Thus, geraniol is activated through both autoxidation and metabolism. The allergens geranial and neral are formed via both oxidation mechanisms, thereby playing a large role in the sensitization to geraniol

  20. Label free imaging of cell-substrate contacts by holographic total internal reflection microscopy.

    Science.gov (United States)

    Mandracchia, Biagio; Gennari, Oriella; Marchesano, Valentina; Paturzo, Melania; Ferraro, Pietro

    2017-09-01

    The study of cell adhesion contacts is pivotal to understand cell mechanics and interaction at substrates or chemical and physical stimuli. We designed and built a HoloTIR microscope for label-free quantitative phase imaging of total internal reflection. Here we show for the first time that HoloTIR is a good choice for label-free study of focal contacts and of cell/substrate interaction as its sensitivity is enhanced in comparison with standard TIR microscopy. Finally, the simplicity of implementation and relative low cost, due to the requirement of less optical components, make HoloTIR a reasonable alternative, or even an addition, to TIRF microscopy for mapping cell/substratum topography. As a proof of concept, we studied the formation of focal contacts of fibroblasts on three substrates with different levels of affinity for cell adhesion. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Chemical and volatile composition of jujube wines fermented by Saccharomyces cerevisiae with and without pulp contact and protease treatment

    Directory of Open Access Journals (Sweden)

    Wenye ZHANG

    2016-01-01

    Full Text Available Abstract This study evaluated the chemical and volatile composition of jujube wines fermented with Saccharomyces cerevisiae A1.25 with and without pulp contact and protease treatment during fermentation. Yeast cell population, total reducing sugar and methanol contents had significant differences between nonextracted and extracted wine. The nonextracted wines had significantly higher concentrations of ethyl 9-hexadecenoate, ethyl palmitate and ethyl oleate than the extracted wines. Pulp contact also could enhance phenylethyl alcohol, furfuryl alcohol, ethyl palmitat and ethyl oleate. Furthermore, protease treatment can accelerate the release of fusel oils. The first principal component separated the wine from the extracted juice without protease from other samples based on the higher concentrations of medium-chain fatty acids and medium-chain ethyl esters. Sensory evaluation showed pulp contact and protease could improve the intensity and complexity of wine aroma due to the increase of the assimilable nitrogen.

  2. A contact angle hysteresis model based on the fractal structure of contact line.

    Science.gov (United States)

    Wu, Shuai; Ma, Ming

    2017-11-01

    Contact angle is one of the most popular concept used in fields such as wetting, transport and microfludics. In practice, different contact angles such as equilibrium, receding and advancing contact angles are observed due to hysteresis. The connection among these contact angles is important in revealing the chemical and physical properties of surfaces related to wetting. Inspired by the fractal structure of contact line, we propose a single parameter model depicting the connection of the three angles. This parameter is decided by the fractal structure of the contact line. The results of this model agree with experimental observations. In certain cases, it can be reduced to other existing models. It also provides a new point of view in understanding the physical nature of the contact angle hysteresis. Interestingly, some counter-intuitive phenomena, such as the binary receding angles, are indicated in this model, which are waited to be validated by experiments. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Experimental study on the influence of chemical sensitizer on pressure resistance in deep water of emulsion explosives

    Science.gov (United States)

    Liu, Lei; zhang, Zhihua; Wang, Ya; Qin, hao

    2018-03-01

    The study on the pressure resistance performance of emulsion explosives in deep water can provide theoretical basis for underwater blasting, deep-hole blasting and emulsion explosives development. The sensitizer is an important component of emulsion explosives. By using reusable experimental devices to simulate the charge environment in deep water, the influence of the content of chemical sensitizer on the deep-water pressure resistance performance of emulsion explosives was studied. The experimental results show that with the increasing of the content of chemical sensitizer, the deep-water pressure resistance performance of emulsion explosives gradually improves, and when the pressure is fairly large, the effect is particularly pronounced; in a certain range, with the increase of the content of chemical sensitizer, that emulsion explosives’ explosion performance also gradually improve, but when the content reaches a certain value, the explosion properties declined instead; under the same emulsion matrix condition, when the content of NANO2 is 0.2%, that the emulsion explosives has good resistance to water pressure and good explosion properties. The correctness of the results above was testified in model blasting.

  4. Test report for remote vs. contact Raman spectroscopy

    International Nuclear Information System (INIS)

    Kyle, K.R.

    1994-05-01

    This report details the evaluation of two methods of spatially characterizing the chemical composition of tank core samples using Raman spectroscopy. One method involves a spatially-scanned fiber optic probe. The fiber optic probe must be in contact with a sample to interrogate its chemical composition. The second method utilizes a line-of-sight technique involving a remote imaging spectrometer that can perform characterization over an entire surface. Measurements using the imaging technique are done remotely, requiring no contact with the sample surface. The scope of this document studies the effects of laser power, distance from each type of probe to the sample surface, and interferences unique to the two methods. This report also documents the results of comparative studies of sensitivity to ferrocyanide, a key contaminant of concern in the underground storage tanks at DOE's Hanford site. The effect of other factors on signal intensity such as moisture content is explored. The results from the two methods are compared, and a recommendation for a Raman hot cell core scanning system is presented based on the test results. This work is part of a joint effort involving several DOE laboratories for the design and development of Raman spectroscopy systems for tank waste characterization at Westinghouse Hanford Company under the auspices of the U.S. Department of Energy's Underground Storage Tank Integrated Demonstration

  5. Predicting chemically-induced skin reactions. Part II: QSAR models of skin permeability and the relationships between skin permeability and skin sensitization

    Science.gov (United States)

    Alves, Vinicius M.; Muratov, Eugene; Fourches, Denis; Strickland, Judy; Kleinstreuer, Nicole; Andrade, Carolina H.; Tropsha, Alexander

    2015-01-01

    Skin permeability is widely considered to be mechanistically implicated in chemically-induced skin sensitization. Although many chemicals have been identified as skin sensitizers, there have been very few reports analyzing the relationships between molecular structure and skin permeability of sensitizers and non-sensitizers. The goals of this study were to: (i) compile, curate, and integrate the largest publicly available dataset of chemicals studied for their skin permeability; (ii) develop and rigorously validate QSAR models to predict skin permeability; and (iii) explore the complex relationships between skin sensitization and skin permeability. Based on the largest publicly available dataset compiled in this study, we found no overall correlation between skin permeability and skin sensitization. In addition, cross-species correlation coefficient between human and rodent permeability data was found to be as low as R2=0.44. Human skin permeability models based on the random forest method have been developed and validated using OECD-compliant QSAR modeling workflow. Their external accuracy was high (Q2ext = 0.73 for 63% of external compounds inside the applicability domain). The extended analysis using both experimentally-measured and QSAR-imputed data still confirmed the absence of any overall concordance between skin permeability and skin sensitization. This observation suggests that chemical modifications that affect skin permeability should not be presumed a priori to modulate the sensitization potential of chemicals. The models reported herein as well as those developed in the companion paper on skin sensitization suggest that it may be possible to rationally design compounds with the desired high skin permeability but low sensitization potential. PMID:25560673

  6. The local lymph node assay: current position in the regulatory classification of skin sensitizing chemicals.

    Science.gov (United States)

    Basketter, David A; Gerberick, G Frank; Kimber, Ian

    2007-01-01

    The local lymph node assay (LLNA) is being used increasingly in the identification of skin sensitizing chemicals for regulatory purposes. In the context of new chemicals legislation (REACH) in Europe, it is the preferred assay. The rationale for this is that the LLNA quantitative and objective approach to skin sensitization testing allied with the important animal welfare benefits that the method offers. However, as with certain guinea pig sensitization tests before it, this increasing use also brings experience with an increasingly wide range of industrial and other chemicals where the outcome of the assay does not always necessarily meet with the expectations of those conducting it. Sometimes, the result appears to be a false negative, but rather more commonly, the complaint is that the chemical represents a false positive. Against this background we have here reviewed a number of instances where false positive and false negative results have been described and have sought to reconcile science with expectation. Based on these analyses, it is our conclusion that false positives and false negatives do occur in the LLNA, as they do with any other skin sensitization assay (and indeed with all tests used for hazard identification), and that this occurs for a number of reasons. We further conclude, however, that false positive results in the LLNA, as with the guinea pig maximization test, arise most commonly via failure to distinguish what is scientifically correct from that which is unpalatable. The consequences of this confusion are discussed in the article, particularly in relation to the need to integrate both potency measurement and risk assessments into classification and labelling schemes that aim to manage potential risks to human health.

  7. Footwear dermatitis - Clinical patterns and contact allergens

    Directory of Open Access Journals (Sweden)

    Handa S

    1991-01-01

    Full Text Available Thirty patients suspected of contact dermatitis to footwear studied to evaluate various clinical presentations and possible sensitizers. ′V′ chappals and sandals were suspected alone in 12, a combination of open and closed shoes in 15 and closed shoes alone in 3 patients. Commonest affected sites were dorsa of feet and toes in 14 and dorsa of feet corresponding to the shape of footwear in 12 patients. Patch tests were done using a battery of sixteen allergens. Positive patch tests were seen in 29 patients. Rubber chemicals were the commonest allergens detected in 26 patients, dyes in 10,leather in 6, glues and neoprene cements in 4 and rubber material from suspected footwear as such in 4 patients respectively.

  8. Allergic contact dermatitis: Patient management and education.

    Science.gov (United States)

    Mowad, Christen M; Anderson, Bryan; Scheinman, Pamela; Pootongkam, Suwimon; Nedorost, Susan; Brod, Bruce

    2016-06-01

    Allergic contact dermatitis is a common diagnosis resulting from exposure to a chemical or chemicals in a patient's personal care products, home, or work environment. Once patch testing has been performed, the education and management process begins. After the causative allergens have been identified, patient education is critical to the proper treatment and management of the patient. This must occur if the dermatitis is to resolve. Detailed education is imperative, and several resources are highlighted. Photoallergic contact dermatitis and occupational contact dermatitis are other considerations a clinician must keep in mind. Copyright © 2015 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  9. Safety Evaluation of Cosmetic Ingredients Regarding Their Skin Sensitization Potential

    Directory of Open Access Journals (Sweden)

    Winfried Steiling

    2016-03-01

    Full Text Available Up to today, product safety evaluation in the EU is predominantly based on data/information on their individual ingredients. Consequently, the quality and reliability of individual ingredient data is of vital interest. In this context, the knowledge about skin sensitization potential is an explicit need for both hazard and risk assessment. Proper skin sensitization data of the individual chemicals is essential, especially when dermal contact is intended, like for cosmetics. In some cases, e.g., in the presence of irritating chemicals, the combination of individual ingredients may also need to be evaluated to cover possible mixture effects. Today, it seems unlikely or even impossible that skin sensitization in humans can be adequately described by a single test result or even by a simple combination of a few data points (in vivo or in vitro. It is becoming evident that a set of data (including human data and market data and knowledge about the ingredient’s specific sensitizing potency needs to be taken into account to enable a reliable assessment of skin sensitization. A more in-depth understanding on mechanistic details of the Adverse-Outcome-Pathway of skin sensitization could contribute key data for a robust conclusion on skin sensitization.

  10. Immunotherapy of allergic contact dermatitis.

    Science.gov (United States)

    Spiewak, Radoslaw

    2011-08-01

    The term 'immunotherapy' refers to treating diseases by inducing, enhancing or suppressing immune responses. As allergy is an excessive, detrimental immune reaction to otherwise harmless environmental substances, immunotherapy of allergic disease is aimed at the induction of tolerance toward sensitizing antigens. This article focuses on the historical developments, present state and future outlook for immunotherapy with haptens as a therapeutic modality for allergic contact dermatitis. Inspired by the effectiveness of immunotherapy in respiratory allergies, attempts were undertaken at curing allergic contact dermatitis by means of controlled administration of the sensitizing haptens. Animal and human experiments confirmed that tolerance to haptens can be induced most effectively when the induction of tolerance precedes attempted sensitization. In real life, however, therapy is sought by people who are already sensitized and an effective reversal of hypersensitivity seems more difficult to achieve. Decades of research on Rhus hypersensitivity led to a conclusion that immunotherapy can suppress Rhus dermatitis, however, only to a limited degree, for a short period of time, and at a high risk of side effects, which makes this method therapeutically unprofitable. Methodological problems with most available studies of immunotherapy of contact allergy to nickel make any definite conclusions impossible at this stage.

  11. Application of BALB/c mouse in the local lymph node assay:BrdU-ELISA for the prediction of the skin sensitizing potential of chemicals.

    Science.gov (United States)

    Hou, Fenxia; Xing, Caihong; Li, Bin; Cheng, Juan; Chen, Wei; Zhang, Man

    2015-01-01

    Allergic contact dermatitis (ACD) is a skin disease characterized by eczema and itching. A considerable proportion of chemicals induce ACD in humans. More than 10,000 substances should be tested for skin sensitization potential under the Registration, Evaluation, Authorization and Restriction of Chemical substances (REACH) regulation. The Local Lymph Node Assay (LLNA) has been designated as the first-choice in vivo assay for sensitization testing by REACH. The LLNA:BrdU-ELISA is a validated non-radioactive modification to the LLNA. For both the LLNA and the LLNA:BrdU-ELISA, CBA/JN mouse is the preferred mouse strain recommended in the regulatory guidelines. However, the availability of CBA/JN mouse in China is only limited to a few animal suppliers, which makes the mouse difficult to obtain. BALB/c mouse, which is widely commercially available, is considered for alternative use but it can only be used in the assay after it has been evaluated by formal validation study. Thus, a validation study was conducted in our laboratory to determine if BALB/c mouse could also be used in the LLNA:BrdU-ELISA. Forty-three test substances including 32 LLNA sensitizers and 11 LLNA non-sensitizers, their vehicles and each concentration used were the same as that used in the formal validation study for the LLNA:BrdU-ELISA using CBA/JN mouse. Female BALB/c mice of 8-10 weeks old were randomly allocated to groups (four mice per group). The test substance (25 μl) or the vehicle alone was applied to the dorsum of both ears daily for 3 consecutive days. A single intraperitoneal injection of 0.5 ml of BrdU (10mg/ml) solution was given on day 5. On day 6, a pair of auricular lymph nodes from each mouse was excised, weighed and stored at -20°C until BrdU-ELISA was conducted. This validation study for the LLNA:BrdU-ELISA using BALB/c mouse correctly identified 30 of 31 sensitizers and 8 of 11 non-sensitizers. The accuracy, sensitivity, specificity, false positive rate, false negative rate

  12. GaN-based vertical-cavity surface-emitting lasers with tunnel junction contacts grown by metal-organic chemical vapor deposition

    Science.gov (United States)

    Lee, SeungGeun; Forman, Charles A.; Lee, Changmin; Kearns, Jared; Young, Erin C.; Leonard, John T.; Cohen, Daniel A.; Speck, James S.; Nakamura, Shuji; DenBaars, Steven P.

    2018-06-01

    We report the first demonstration of III–nitride vertical-cavity surface-emitting lasers (VCSELs) with tunnel junction (TJ) intracavity contacts grown completely by metal–organic chemical vapor deposition (MOCVD). For the TJs, n++-GaN was grown on in-situ activated p++-GaN after buffered HF surface treatment. The electrical properties and epitaxial morphologies of the TJs were first investigated on TJ LED test samples. A VCSEL with a TJ intracavity contact showed a lasing wavelength of 408 nm, a threshold current of ∼15 mA (10 kA/cm2), a threshold voltage of 7.8 V, a maximum output power of 319 µW, and a differential efficiency of 0.28%.

  13. Predicting chemically-induced skin reactions. Part II: QSAR models of skin permeability and the relationships between skin permeability and skin sensitization

    Energy Technology Data Exchange (ETDEWEB)

    Alves, Vinicius M. [Laboratory of Molecular Modeling and Design, Faculty of Pharmacy, Federal University of Goiás, Goiânia, GO 74605-220 (Brazil); Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States); Muratov, Eugene [Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States); Laboratory of Theoretical Chemistry, A.V. Bogatsky Physical–Chemical Institute NAS of Ukraine, Odessa 65080 (Ukraine); Fourches, Denis [Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States); Strickland, Judy; Kleinstreuer, Nicole [ILS/Contractor supporting the NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM), P.O. Box 13501, Research Triangle Park, NC 27709 (United States); Andrade, Carolina H. [Laboratory of Molecular Modeling and Design, Faculty of Pharmacy, Federal University of Goiás, Goiânia, GO 74605-220 (Brazil); Tropsha, Alexander, E-mail: alex_tropsha@unc.edu [Laboratory for Molecular Modeling, Division of Chemical Biology and Medicinal Chemistry, Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599 (United States)

    2015-04-15

    Skin permeability is widely considered to be mechanistically implicated in chemically-induced skin sensitization. Although many chemicals have been identified as skin sensitizers, there have been very few reports analyzing the relationships between molecular structure and skin permeability of sensitizers and non-sensitizers. The goals of this study were to: (i) compile, curate, and integrate the largest publicly available dataset of chemicals studied for their skin permeability; (ii) develop and rigorously validate QSAR models to predict skin permeability; and (iii) explore the complex relationships between skin sensitization and skin permeability. Based on the largest publicly available dataset compiled in this study, we found no overall correlation between skin permeability and skin sensitization. In addition, cross-species correlation coefficient between human and rodent permeability data was found to be as low as R{sup 2} = 0.44. Human skin permeability models based on the random forest method have been developed and validated using OECD-compliant QSAR modeling workflow. Their external accuracy was high (Q{sup 2}{sub ext} = 0.73 for 63% of external compounds inside the applicability domain). The extended analysis using both experimentally-measured and QSAR-imputed data still confirmed the absence of any overall concordance between skin permeability and skin sensitization. This observation suggests that chemical modifications that affect skin permeability should not be presumed a priori to modulate the sensitization potential of chemicals. The models reported herein as well as those developed in the companion paper on skin sensitization suggest that it may be possible to rationally design compounds with the desired high skin permeability but low sensitization potential. - Highlights: • It was compiled the largest publicly-available skin permeability dataset. • Predictive QSAR models were developed for skin permeability. • No concordance between skin

  14. Predicting chemically-induced skin reactions. Part II: QSAR models of skin permeability and the relationships between skin permeability and skin sensitization

    International Nuclear Information System (INIS)

    Alves, Vinicius M.; Muratov, Eugene; Fourches, Denis; Strickland, Judy; Kleinstreuer, Nicole; Andrade, Carolina H.; Tropsha, Alexander

    2015-01-01

    Skin permeability is widely considered to be mechanistically implicated in chemically-induced skin sensitization. Although many chemicals have been identified as skin sensitizers, there have been very few reports analyzing the relationships between molecular structure and skin permeability of sensitizers and non-sensitizers. The goals of this study were to: (i) compile, curate, and integrate the largest publicly available dataset of chemicals studied for their skin permeability; (ii) develop and rigorously validate QSAR models to predict skin permeability; and (iii) explore the complex relationships between skin sensitization and skin permeability. Based on the largest publicly available dataset compiled in this study, we found no overall correlation between skin permeability and skin sensitization. In addition, cross-species correlation coefficient between human and rodent permeability data was found to be as low as R 2 = 0.44. Human skin permeability models based on the random forest method have been developed and validated using OECD-compliant QSAR modeling workflow. Their external accuracy was high (Q 2 ext = 0.73 for 63% of external compounds inside the applicability domain). The extended analysis using both experimentally-measured and QSAR-imputed data still confirmed the absence of any overall concordance between skin permeability and skin sensitization. This observation suggests that chemical modifications that affect skin permeability should not be presumed a priori to modulate the sensitization potential of chemicals. The models reported herein as well as those developed in the companion paper on skin sensitization suggest that it may be possible to rationally design compounds with the desired high skin permeability but low sensitization potential. - Highlights: • It was compiled the largest publicly-available skin permeability dataset. • Predictive QSAR models were developed for skin permeability. • No concordance between skin sensitization and

  15. Lack of contralateral suppression in transient-evoked otoacoustic emissions in multiple chemical sensitivity: a clinical correlation study

    Directory of Open Access Journals (Sweden)

    Alessandro Micarelli

    2016-01-01

    Full Text Available Multiple chemical sensitivity (MCS is a chronic disorder characterized by a variety of symptoms associated with the exposure to chemicals at a concentration below the toxic level. Previous studies have demonstrated peculiar responses in brain activity in these patients with respect to sensory stimuli while the association between chemical sensitivity and other environmental intolerances such as noise sensitivity has been questioned by researchers. In this study, a cohort of 18 MCS patients underwent transient-evoked otoacoustic emission (TEOAE testing with and without contralateral suppression to evaluate the functionality of the medial olivocochlear (MOC reflex involved in speech-in-noise sensitivity. Results were compared with an age- and gender-matched control group (n = 20 and correlation analysis with disease onset and quick environmental exposure sensitivity inventory (qEESI symptom severity scale was performed. Subjects affected by MCS showed statistically significant impairment of MOC reflex, and the onset of the disease and several symptom subscales showed to be correlated to such reduction in some of the frequencies tested. These data suggest that alterations of MOC reflex could be part of the complex features of this disease although more studies are needed to further explore auditory perception disorders in environmental intolerances.

  16. Evaluation of non-radioactive endpoints of ex vivo local lymph node assay-BrdU to investigate select contact sensitizers.

    Science.gov (United States)

    Ulker, Ozge Cemiloglu; Ates, Ilker; Atak, Aysegul; Karakaya, Asuman

    2013-01-01

    The present study sought to verify the utility of the non-radioactive endpoints LLNA BrdU (5-bromo-2'-deoxyuridine) ex vivo incorporation and cytokine release using auricular lymph node cells isolated from BALB/c mice topically treated with a strong (formaldehyde or p-phenylene-diamine [PPD]), moderate sensitizer (cinnamal), or weak sensitizer (eugenol). Stimulation index (SI) and EC₃ values were calculated for each agent. Based on the results of ex vivo LLNA-BrdU assays, EC₃ values were calculated to be 0.29, 0.09, 1.91, and 16.60% for formaldehyde, PPD, cinnamal, and eugenol, respectively. These results were in good agreement with data from previous standard radioactive LLNA. Cytokine analyses indicated T(H)1 and T(H)2 cytokine involvement in the regulation of murine contact allergy and these could be utilized as endpoints in assessments of contact allergy in mice. In conclusion, the current study provided evidence that the non-radioactive endpoint LLNA BrdU ex vivo incorporation could be of use as a viable alternative approach to assess the skin sensitization potential of test compound with respect to improving animal welfare. This is of particular importance in the case of any laboratory where it might be difficult to handle and/or readily employ radioisotopes. Further studies will be required to confirm--across test agents--the reproducibility as well as the limits of utility of this new ex vivo BrdU method.

  17. Comparative sensitivity of human and rat neural cultures to chemical-induced inhibition of neurite outgrowth

    Energy Technology Data Exchange (ETDEWEB)

    Harrill, Joshua A.; Freudenrich, Theresa M.; Robinette, Brian L.; Mundy, William R., E-mail: mundy.william@epa.gov

    2011-11-15

    There is a need for rapid, efficient and cost-effective alternatives to traditional in vivo developmental neurotoxicity testing. In vitro cell culture models can recapitulate many of the key cellular processes of nervous system development, including neurite outgrowth, and may be used as screening tools to identify potential developmental neurotoxicants. The present study compared primary rat cortical cultures and human embryonic stem cell-derived neural cultures in terms of: 1) reproducibility of high content image analysis based neurite outgrowth measurements, 2) dynamic range of neurite outgrowth measurements and 3) sensitivity to chemicals which have been shown to inhibit neurite outgrowth. There was a large increase in neurite outgrowth between 2 and 24 h in both rat and human cultures. Image analysis data collected across multiple cultures demonstrated that neurite outgrowth measurements in rat cortical cultures were more reproducible and had higher dynamic range as compared to human neural cultures. Human neural cultures were more sensitive than rat cortical cultures to chemicals previously shown to inhibit neurite outgrowth. Parallel analysis of morphological (neurite count, neurite length) and cytotoxicity (neurons per field) measurements were used to detect selective effects on neurite outgrowth. All chemicals which inhibited neurite outgrowth in rat cortical cultures did so at concentrations which did not concurrently affect the number of neurons per field, indicating selective effects on neurite outgrowth. In contrast, more than half the chemicals which inhibited neurite outgrowth in human neural cultures did so at concentrations which concurrently decreased the number of neurons per field, indicating that effects on neurite outgrowth were secondary to cytotoxicity. Overall, these data demonstrate that the culture models performed differently in terms of reproducibility, dynamic range and sensitivity to neurite outgrowth inhibitors. While human neural

  18. Comparative sensitivity of human and rat neural cultures to chemical-induced inhibition of neurite outgrowth

    International Nuclear Information System (INIS)

    Harrill, Joshua A.; Freudenrich, Theresa M.; Robinette, Brian L.; Mundy, William R.

    2011-01-01

    There is a need for rapid, efficient and cost-effective alternatives to traditional in vivo developmental neurotoxicity testing. In vitro cell culture models can recapitulate many of the key cellular processes of nervous system development, including neurite outgrowth, and may be used as screening tools to identify potential developmental neurotoxicants. The present study compared primary rat cortical cultures and human embryonic stem cell-derived neural cultures in terms of: 1) reproducibility of high content image analysis based neurite outgrowth measurements, 2) dynamic range of neurite outgrowth measurements and 3) sensitivity to chemicals which have been shown to inhibit neurite outgrowth. There was a large increase in neurite outgrowth between 2 and 24 h in both rat and human cultures. Image analysis data collected across multiple cultures demonstrated that neurite outgrowth measurements in rat cortical cultures were more reproducible and had higher dynamic range as compared to human neural cultures. Human neural cultures were more sensitive than rat cortical cultures to chemicals previously shown to inhibit neurite outgrowth. Parallel analysis of morphological (neurite count, neurite length) and cytotoxicity (neurons per field) measurements were used to detect selective effects on neurite outgrowth. All chemicals which inhibited neurite outgrowth in rat cortical cultures did so at concentrations which did not concurrently affect the number of neurons per field, indicating selective effects on neurite outgrowth. In contrast, more than half the chemicals which inhibited neurite outgrowth in human neural cultures did so at concentrations which concurrently decreased the number of neurons per field, indicating that effects on neurite outgrowth were secondary to cytotoxicity. Overall, these data demonstrate that the culture models performed differently in terms of reproducibility, dynamic range and sensitivity to neurite outgrowth inhibitors. While human neural

  19. Novel chemically cross-linked solid state electrolyte for dye-sensitized solar cells

    International Nuclear Information System (INIS)

    Yin Xiong; Tan Weiwei; Xiang Wangchun; Lin Yuan; Zhang Jingbo; Xiao Xurui; Li Xueping; Zhou Xiaowen; Fang Shibi

    2010-01-01

    Poly(vinylpyridine-co-ethylene glycol methyl ether methacrylate) (P(VP-co-MEOMA)) and α,ω-diiodo poly(ethylene oxide-co-propylene oxide) (I[(EO) 0.8 -co-(PO) 0.2 ] y I) were synthesized and used as chemically cross-linked precursors of the electrolyte for dye-sensitized solar cells. Meanwhile, α-iodo poly(ethylene oxide-co-propylene oxide) methyl ether (CH 3 O[(EO) 0.8 -co-(PO) 0.2 ] x I) was synthesized and added into the electrolyte as an internal plasticizer. Novel polymer electrolyte resulting from chemically cross-linked precursors was obtained by the quaterisation at 90 o C for 30 min. The characteristics for this kind of electrolyte were investigated by means of ionic conductivity, thermogravimetric and photocurrent-voltage. The ambient ionic conductivity was significantly enhanced to 2.3 x 10 -4 S cm -1 after introducing plasticizer, modified-ionic liquid. The weight loss of the solid state electrolyte at 200 o C was 1.8%, and its decomposition temperature was 287 o C. Solid state dye-sensitized solar cell based on chemically cross-linked electrolyte presented an overall conversion efficiency of 2.35% under AM1.5 irradiation (100 mW cm -2 ). The as-fabricated device maintained 88% of its initial performance at room temperature even without sealing for 30 days, showing a good stability.

  20. Dimethyl fumarate contact dermatitis of the foot: an increasingly widespread disease.

    Science.gov (United States)

    D'Erme, Angelo Massimiliano; Bassi, Andrea; Lotti, Torello; Gola, Massimo

    2012-01-01

    Dimethyl fumarate (DMF) has been recognized as an extremely potent irritant and sensitizer found in sachets inside furniture. The first skin manifestations were correlated to contact with sofas, chairs, and other furniture. In these last years, some papers have reported a development of allergic contact dermatitis on the foot caused by DMF present in high concentration in shoes made in China. We report the case of a 37-year-old woman who presented with severe eczema on the foot shortly after having bought a new pair of shoes. The diagnosis was performed by patch tests with DMF in several dilutions, with pieces of internal and external parts of the shoes, and by chemical analysis of the shoes. In the last three years, goods containing DMF increased diffusely despite the augmentation on global preventive measures by Europe. Therefore, new cases of contact dermatitis could be dependent on DMF, and it is of note that this allergen is not included in most series for patch testing. © 2011 The International Society of Dermatology.

  1. Evaluation of a high-throughput peptide reactivity format assay for assessment of the skin sensitization potential of chemicals

    Directory of Open Access Journals (Sweden)

    Chin Lin eWong

    2016-03-01

    Full Text Available The direct peptide reactivity assay (DPRA is a validated method for in vitro assessment of the skin sensitization potential of chemicals. In the present work, we describe a peptide reactivity assay using 96-well plate format and systematically identified the optimal assay conditions for accurate and reproducible classification of chemicals with known sensitizing capacity. The aim of the research is to ensure that the analytical component of the peptide reactivity assay is robust, accurate and reproducible in accordance with criteria that are used for the validation of bioanalytical methods. Analytical performance was evaluated using quality control samples (QCs; heptapeptides at low, medium and high concentrations and incubation of control chemicals (chemicals with known sensitization capacity, weak, moderate, strong, extreme and non-sensitizers with each of three synthetic heptapeptides, viz Cor1-C420 (Ac-NKKCDLF, cysteine- (Ac-RFAACAA and lysine- (Ac-RFAAKAA containing heptapeptides. The optimal incubation temperature for all three heptapeptides was 25°C. Apparent heptapeptide depletion was affected by vial material composition. Incubation of test chemicals with Cor1-C420, showed that peptide depletion was unchanged in polypropylene vials over 3-days storage in an autosampler but this was not the case for borosilicate glass vials. For cysteine-containing heptapeptide, the concentration was not stable by day 3 post-incubation in borosilicate glass vials. Although the lysine-containing heptapeptide concentration was unchanged in both polypropylene and borosilicate glass vials, the apparent extent of lysine-containing heptapeptide depletion by ethyl acrylate, differed between polypropylene (24.7% and glass (47.3% vials. Additionally, the peptide-chemical complexes for Cor1-C420-cinnamaldehyde and cysteine-containing heptapeptide-2,4-dinitrochlorobenzene were partially reversible during 3-days of autosampler storage. These observations further

  2. Wound-Related Allergic/Irritant Contact Dermatitis.

    Science.gov (United States)

    Alavi, Afsaneh; Sibbald, R Gary; Ladizinski, Barry; Saraiya, Ami; Lee, Kachiu C; Skotnicki-Grant, Sandy; Maibach, Howard

    2016-06-01

    To provide information from a literature review about the prevention, recognition, and treatment for contact dermatitis. This continuing education activity is intended for physicians and nurses with an interest in skin and wound care. After participating in this educational activity, the participant should be better able to:1. Identify signs and symptoms of and diagnostic measures for contact dermatitis.2. Identify causes and risks for contact dermatitis.3. Select appropriate treatment for contact dermatitis and its prevention. Contact dermatitis to wound care products is a common, often neglected problem. A review was conducted to identify articles relevant to contact dermatitis.A PubMed English-language literature review was conducted for appropriate articles published between January 2000 and December 2015.Contact dermatitis is both irritant (80% of cases) or allergic (20% of cases). Frequent use of potential contact allergens and impaired barrier function of the skin can lead to rising sensitization in patients with chronic wounds. Common known allergens to avoid in wound care patients include fragrances, colophony, lanolin, and topical antibiotics.Clinicians should be cognizant of the allergens in wound care products and the potential for sensitization. All medical devices, including wound dressings, adhesives, and bandages, should be labeled with their complete ingredients, and manufacturers should be encouraged to remove common allergens from wound care products, including topical creams, ointments, and dressings.

  3. Sensitivity of the Early Development of Ramshorn Snail, Marisa cornuarietis (Ampullariidae) to Environmental Chemicals

    OpenAIRE

    Sawasdee, Banthita

    2011-01-01

    In this study, the suitability of the M. cornuarietis embryo toxicity test (MariETT) for environmental chemicals was investigated. The purpose of this study was to determine the sensitivity of the recently introduced M. cornuarietis embryo toxicity test (MariETT) using selected metals (inorganic pollutants) and pesticides (organic pollutants), and to compare its sensitivity and practicability to other established bioassay. The following endpoints were observed: mortality, formation of tentacl...

  4. Occupational contact dermatitis in hairdressers

    DEFF Research Database (Denmark)

    Schwensen, Jakob F; Johansen, Jeanne Duus; Veien, Niels K

    2013-01-01

    BACKGROUND: Occupational contact dermatitis among hairdressers is frequent, owing to daily exposure to irritants and allergens. OBJECTIVES: To identify sensitization to the most common allergens associated with the occupation of hairdressing. METHODS: Patch test results of 399 hairdressers and 1995...... matched controls with contact dermatitis, registered by the Danish Contact Dermatitis Group between January 2002 and December 2011, were analysed. All patients were patch tested with the European baseline series, and hairdressers were additionally tested with the hairdressing series. RESULTS: Occupational...... contact dermatitis (p dermatitis was less commonly observed among hairdressers (21.3%) than among controls (29.4%) (p 

  5. OCCUPATIONAL CONTACT DERMATITIS AMONGST DENTISTS AND DENTAL TECHNICIANS.

    Science.gov (United States)

    Lugović-Mihić, Liborija; Ferček, Iva; Duvančić, Tomislav; Bulat, Vedrana; Ježovita, Josip; Novak-Bilić, Gaby; Šitum, Mirna

    2016-06-01

    Since the working medical personnel including dentists and dental technicians mainly use their hands, it is understandable that the most common occupational disease amongst medical personnel is contact dermatitis (CD) (80%-90% of cases). Development of occupational CD is caused by contact of the skin with various substances in occupational environment. Occupational etiologic factors for dental personnel are foremost reactions to gloves containing latex, followed by various dental materials (e.g., metals, acrylates), detergents, lubricants, solvents, chemicals, etc. Since occupational CD is relatively common in dental personnel, its timely recognition, treatment and taking preventive measures is needed. Achieving skin protection at exposed workplaces is of special importance, as well as implementing necessary measures consequently and sufficiently, which is sometimes difficult to achieve. Various studies have shown the benefit of applying preventive measures, such as numerous protocols for reducing and managing latex sensitivity and other forms of CD in dentistry. Active involvement of physicians within the health care system, primarily dermatologists, occupational medicine specialists and general medicine doctors is needed for establishing an accurate medical diagnosis and confirmation of occupational skin disease.

  6. Two-Dimensional Photonic Crystals for Sensitive Microscale Chemical and Biochemical Sensing

    Science.gov (United States)

    Miller, Benjamin L.

    2015-01-01

    Photonic crystals – optical devices able to respond to changes in the refractive index of a small volume of space – are an emerging class of label-free chemical-and bio-sensors. This review focuses on one class of photonic crystal, in which light is confined to a patterned planar material layer of sub-wavelength thickness. These devices are small (on the order of tens to 100s of microns square), suitable for incorporation into lab-on-a-chip systems, and in theory can provide exceptional sensitivity. We introduce the defining characteristics and basic operation of two-dimensional photonic crystal sensors, describe variations of their basic design geometry, and summarize reported detection results from chemical and biological sensing experiments. PMID:25563402

  7. Ultra-high sensitive hydrazine chemical sensor based on low-temperature grown ZnO nanoparticles

    International Nuclear Information System (INIS)

    Mehta, S.K.; Singh, Kulvinder; Umar, Ahmad; Chaudhary, G.R.; Singh, Sukhjinder

    2012-01-01

    Graphical abstract: Systematic representation of the fabricated amperometric hydrazine chemical sensor based on ZnO NPs/Au modified electrode. Highlights: ► Synthesis of well-crystalline ZnO NPs has been achieved in aqueous solution. ► ZnO NPs act as efficient electron mediators for hydrazine sensor. ► Extremely high sensitivity and low-detection limit have been obtained. - Abstract: Using well-crystalline ZnO nanoparticles (NPs), an ultra high sensitive hydrazine amperometric sensor has been fabricated and reported in this paper. The ZnO NPs have been synthesized by very simple aqueous solution process at 90 °C and characterized in detail in terms of their morphological, compositional, structural and optical properties. The detailed investigations reveal that the synthesized products are well-crystalline NPs, possessing wurtzite hexagonal phase and exhibit good optical properties. The fabricated amperometric hydrazine sensor exhibits ultra-high sensitivity of ∼97.133 μA cm −2 μM −1 and very low-detection limit of 147.54 nM. To the best of our knowledge, this is the first report in which an ultra-high sensitivity and low-detection limit have been obtained for the hydrazine chemical sensor based on ZnO nanostructures.

  8. Identification of Lilial as a fragrance sensitizer in a perfume by bioassay-guided chemical fractionation and structure-activity relationships

    DEFF Research Database (Denmark)

    Gimenéz-Arnau, Elena; Andersen, K E; Bruze, M

    2000-01-01

    Fragrance materials are among the most common causes of allergic contact dermatitis. The aim of this study was to identify in a perfume fragrance allergens not included in the fragrance mix, by use of bioassay-guided chemical fractionation and chemical analysis/structure-activity relationships...... (SARs). The basis for the investigation was a 45-year-old woman allergic to her own perfume. She had a negative patch test to the fragrance mix and agreed to participate in the study. Chemical fractionation of the perfume concentrate was used for repeated patch testing and/or repeated open application...

  9. Treatment of high-salinity chemical wastewater by indigenous bacteria--bioaugmented contact oxidation.

    Science.gov (United States)

    Li, Qiang; Wang, Mengdi; Feng, Jun; Zhang, Wei; Wang, Yuanyuan; Gu, Yanyan; Song, Cunjiang; Wang, Shufang

    2013-09-01

    A 90 m(3) biological contact oxidation system in chemical factory was bioaugmented with three strains of indigenous salt-tolerant bacteria. These three strains were screened from contaminative soil in situ. Their activity of growth and degradation was investigated with lab-scale experiments. Their salt-tolerant mechanism was confirmed to be compatible-solutes strategy for moderately halophilic bacteria, with amino acid and betaine playing important roles. The running conditions of the system were recorded for 150 days. The indigenous bacteria had such high suitability that the reactor got steady rapidly and the removal of COD maintained above 90%. It was introduced that biofilm fragments in sedimentation tank were inversely flowed to each reaction tank, and quantitative PCR demonstrated that this process could successfully maintain the bacterial abundance in the reaction tanks. In addition, the T-RFLP revealed that bioaugmented strains dominated over others in the biofilm. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Electroconvulsive therapy substantially reduces symptom severity and social disability associated with multiple chemical sensitivity: a case report

    DEFF Research Database (Denmark)

    Elberling, Jesper; Gulmann, Nils; Rasmussen, Alice

    2010-01-01

    Multiple chemical sensitivity (MCS) is a chronic nonallergic, multisymptom disorder triggered by common environmental chemicals in concentrations considered nontoxic for most individuals. The condition may lead to loss of occupation and social isolation, and no effective treatment has been reported...

  11. THP-1 monocytes but not macrophages as a potential alternative for CD34+ dendritic cells to identify chemical skin sensitizers

    International Nuclear Information System (INIS)

    Lambrechts, Nathalie; Verstraelen, Sandra; Lodewyckx, Hanne; Felicio, Ana; Hooyberghs, Jef; Witters, Hilda; Tendeloo, Viggo van; Cauwenberge, Paul van; Nelissen, Inge; Heuvel, Rosette van den; Schoeters, Greet

    2009-01-01

    Early detection of the sensitizing potential of chemicals is an emerging issue for chemical, pharmaceutical and cosmetic industries. In our institute, an in vitro classification model for prediction of chemical-induced skin sensitization based on gene expression signatures in human CD34 + progenitor-derived dendritic cells (DC) has been developed. This primary cell model is able to closely mimic the induction phase of sensitization by Langerhans cells in the skin, but it has drawbacks, such as the availability of cord blood. The aim of this study was to investigate whether human in vitro cultured THP-1 monocytes or macrophages display a similar expression profile for 13 predictive gene markers previously identified in DC and whether they also possess a discriminating capacity towards skin sensitizers and non-sensitizers based on these marker genes. To this end, the cell models were exposed to 5 skin sensitizers (ammonium hexachloroplatinate IV, 1-chloro-2,4-dinitrobenzene, eugenol, para-phenylenediamine, and tetramethylthiuram disulfide) and 5 non-sensitizers (L-glutamic acid, methyl salicylate, sodium dodecyl sulfate, tributyltin chloride, and zinc sulfate) for 6, 10, and 24 h, and mRNA expression of the 13 genes was analyzed using real-time RT-PCR. The transcriptional response of 7 out of 13 genes in THP-1 monocytes was significantly correlated with DC, whereas only 2 out of 13 genes in THP-1 macrophages. After a cross-validation of a discriminant analysis of the gene expression profiles in the THP-1 monocytes, this cell model demonstrated to also have a capacity to distinguish skin sensitizers from non-sensitizers. However, the DC model was superior to the monocyte model for discrimination of (non-)sensitizing chemicals.

  12. Fragrance allergic contact dermatitis.

    Science.gov (United States)

    Cheng, Judy; Zug, Kathryn A

    2014-01-01

    Fragrances are a common cause of allergic contact dermatitis in Europe and in North America. They can affect individuals at any age and elicit a spectrum of reactions from contact urticaria to systemic contact dermatitis. Growing recognition of the widespread use of fragrances in modern society has fueled attempts to prevent sensitization through improved allergen identification, labeling, and consumer education. This review provides an overview and update on fragrance allergy. Part 1 discusses the epidemiology and evaluation of suspected fragrance allergy. Part 2 reviews screening methods, emerging fragrance allergens, and management of patients with fragrance contact allergy. This review concludes by examining recent legislation on fragrances and suggesting potential additions to screening series to help prevent and detect fragrance allergy.

  13. Allergic contact dermatitis caused by isobornyl acrylate in OmniPod, an innovative tubeless insulin pump.

    Science.gov (United States)

    Raison-Peyron, Nadia; Mowitz, Martin; Bonardel, Nathalie; Aerts, Olivier; Bruze, Magnus

    2018-04-10

    The frequency of allergic contact dermatitis caused by (meth)acrylates is increasing worldwide, and isobornyl acrylate (IBOA) has been identified as a culprit sensitizer in FreeStyle Libre, a medical device used by diabetic patients. To report on 4 patients sensitized to IBOA contained in OmniPod, a new, tubeless insulin pump, and to describe the clinical and chemical analytical work-up. Four patients with eczematous skin eruptions after using OmniPod, including 2 with previous adverse skin reactions to FreeStyle Libre, were patch tested with a baseline series and additional (meth)acrylates, including IBOA in several concentrations and/or vehicles. Gas chromatography-mass spectrometry (GC-MS) was used to identify the presence of IBOA in OmniPod. All patients were shown to be sensitized to IBOA. GC-MS identified IBOA in OmniPod, with the highest concentrations being found in the unit itself and not in the adhesive patch. The OmniPod tubeless insulin pump is another source of IBOA, and its use may lead to primary sensitization to this acrylate, or may provoke elicitation of allergic contact dermatitis in previously sensitized patients. Our cases highlight the need to obtain satisfactory cooperation from pharmaceutical companies involved in the manufacture of these widely used medical devices. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. [Multiple chemical sensitivity: Clinical evaluation of the severity and psychopathological profile].

    Science.gov (United States)

    Lago Blanco, Eva; Puiguriguer Ferrando, Jordi; Rodríguez Enríquez, Mónica; Agüero Gento, Laura; Salvà Coll, Joan; Pizà Portell, Maria Rosa

    2016-02-05

    Multiple chemical sensitivity (MCS) is a multisystem disorder of controversial etiology, affecting some subjects when exposed to chemicals at no harmful concentrations. The objective of this paper is to describe the epidemiological, clinical and psychological features of a sample of patients with MCS for further specific group treatment. Descriptive study of patients diagnosed with MCS in a toxicology unit. We administered the Quick Environmental Exposure and Sensitivity Inventory, the structured interview SCID-II, the anxiety scale HAS and the type A personality test, PCTA. Seventy-three patients were included. The mean age was 52,6 years (range 33-77; SD 9.29). Sixty-six were females (90.4%). Fifty-three percent were classified as i-ii and ii grade. Sixty-one patients (83%) presented some type of comorbidity, mainly chronic pain, fibromyalgia and chronic fatigue. They exhibited higher levels of anxiety (average score of 19.2), prevalence of phobic-avoidant traits of personality and type A behavior in 31.1%. MCS affects middle-aged women with comorbidities (chronic pain, fibromyalgia and chronic fatigue) and high anxiety and avoidance behaviors. This preliminary analysis should help provide a specific therapeutic approach to these patients. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  15. Contact activation of blood-plasma coagulation

    Science.gov (United States)

    Golas, Avantika

    Surface engineering of biomaterials with improved hemocompatibility is an imperative, given the widespread global need for cardiovascular devices. Research summarized in this dissertation focuses on contact activation of FXII in buffer and blood plasma frequently referred to as autoactivation. The extant theory of contact activation imparts FXII autoactivation ability to negatively charged, hydrophilic surfaces. According to this theory, contact activation of plasma involves assembly of proteins comprising an "activation complex" on activating surfaces mediated by specific chemical interactions between complex proteins and the surface. This work has made key discoveries that significantly improve our core understanding of contact activation and unravel the existing paradigm of plasma coagulation. It is shown herein that contact activation of blood factor XII (FXII, Hageman factor) in neat-buffer solution exhibits a parabolic profile when scaled as a function of silanized-glass-particle activator surface energy (measured as advancing water adhesion tension t°a=g° Iv costheta in dyne/cm, where g°Iv is water interfacial tension in dyne/cm and theta is the advancing contact angle). Nearly equal activation is observed at the extremes of activator water-wetting properties --36 moderated by adsorption of plasma proteins unrelated to coagulation through an "adsorption-dilution" effect that blocks FXII contact with hydrophobic activator surfaces. The adsorption-dilution effect explains the apparent specificity for hydrophilic activators pursued by earlier investigators. Finally a comparison of FXII autoactivation in buffer, serum, protein cocktail, and plasma solutions is shown herein. Activation of blood plasma coagulation in vitro by contact with material surfaces is demonstrably dependent on plasma-volume-to-activator-surface-area ratio. However, activation of factor XII dissolved in buffer, protein cocktail, heat-denatured serum, and FXI deficient plasma does not

  16. Identifying populations sensitive to environmental chemicals by simulating toxicokinetic variability.

    Science.gov (United States)

    Ring, Caroline L; Pearce, Robert G; Setzer, R Woodrow; Wetmore, Barbara A; Wambaugh, John F

    2017-09-01

    physiological parameters for a virtual population. For risk-based prioritization of chemicals, predicted bioactive equivalent doses were compared to demographic-specific inferences of exposure rates that were based on NHANES urinary analyte biomonitoring data. The inclusion of NHANES-derived inter-individual variability decreased predicted bioactive equivalent doses by 12% on average for the total population when compared to previous methods. However, for some combinations of chemical and demographic groups the margin was reduced by as much as three quarters. This TK modeling framework allows targeted risk prioritization of chemicals for demographic groups of interest, including potentially sensitive life stages and subpopulations. Published by Elsevier Ltd.

  17. Advantages of chemical exchange-sensitive spin-lock (CESL) over chemical exchange saturation transfer (CEST) for hydroxyl- and amine-water proton exchange studies.

    Science.gov (United States)

    Jin, Tao; Kim, Seong-Gi

    2014-11-01

    The chemical exchange (CE) rate of endogenous hydroxyl and amine protons with water is often comparable to the difference in their chemical shifts. These intermediate exchange processes have been imaged by the CE saturation transfer (CEST) approach with low-power and long-duration irradiation. However, the sensitivity is not optimal and, more importantly, the signal is contaminated by slow magnetization transfer processes. Here, the properties of CEST signals are compared with those of a CE-sensitive spin-lock (CESL) technique irradiating at the labile proton frequency. First, using a higher power and shorter irradiation in CE-MRI, we obtain: (i) an increased selectivity to faster CE rates via a higher sensitivity to faster CEs and a lower sensitivity to slower CEs and magnetization transfer processes; and (ii) a decreased in vivo asymmetric magnetization transfer contrast measured at ±15 ppm. The sensitivity gain of CESL over CEST is higher for a higher power and shorter irradiation. Unlike CESL, CEST signals oscillate at a very high power and short irradiation. Second, time-dependent CEST and CESL signals are well modeled by analytical solutions of CE-MRI with an asymmetric population approximation, which can be used for quantitative CE-MRI and validated by simulations of Bloch-McConnell equations and phantom experiments. Finally, the in vivo amine-water proton exchange contrast measured at 2.5 ppm with ω1 = 500 Hz is 18% higher in sensitivity for CESL than CEST at 9.4 T. Overall, CESL provides better exchange rate selectivity and sensitivity than CEST; therefore, CESL is more suitable for CE-MRI of intermediate exchange protons. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Reduction and Uncertainty Analysis of Chemical Mechanisms Based on Local and Global Sensitivities

    Science.gov (United States)

    Esposito, Gaetano

    Numerical simulations of critical reacting flow phenomena in hypersonic propulsion devices require accurate representation of finite-rate chemical kinetics. The chemical kinetic models available for hydrocarbon fuel combustion are rather large, involving hundreds of species and thousands of reactions. As a consequence, they cannot be used in multi-dimensional computational fluid dynamic calculations in the foreseeable future due to the prohibitive computational cost. In addition to the computational difficulties, it is also known that some fundamental chemical kinetic parameters of detailed models have significant level of uncertainty due to limited experimental data available and to poor understanding of interactions among kinetic parameters. In the present investigation, local and global sensitivity analysis techniques are employed to develop a systematic approach of reducing and analyzing detailed chemical kinetic models. Unlike previous studies in which skeletal model reduction was based on the separate analysis of simple cases, in this work a novel strategy based on Principal Component Analysis of local sensitivity values is presented. This new approach is capable of simultaneously taking into account all the relevant canonical combustion configurations over different composition, temperature and pressure conditions. Moreover, the procedure developed in this work represents the first documented inclusion of non-premixed extinction phenomena, which is of great relevance in hypersonic combustors, in an automated reduction algorithm. The application of the skeletal reduction to a detailed kinetic model consisting of 111 species in 784 reactions is demonstrated. The resulting reduced skeletal model of 37--38 species showed that the global ignition/propagation/extinction phenomena of ethylene-air mixtures can be predicted within an accuracy of 2% of the full detailed model. The problems of both understanding non-linear interactions between kinetic parameters and

  19. Modeling leukocyte-leukocyte non-contact interactions in a lymph node.

    Directory of Open Access Journals (Sweden)

    Nicola Gritti

    Full Text Available The interaction among leukocytes is at the basis of the innate and adaptive immune-response and it is largely ascribed to direct cell-cell contacts. However, the exchange of a number of chemical stimuli (chemokines allows also non-contact interaction during the immunological response. We want here to evaluate the extent of the effect of the non-contact interactions on the observed leukocyte-leukocyte kinematics and their interaction duration. To this aim we adopt a simplified mean field description inspired by the Keller-Segel chemotaxis model, of which we report an analytical solution suited for slowly varying sources of chemokines. Since our focus is on the non-contact interactions, leukocyte-leukocyte contact interactions are simulated only by means of a space dependent friction coefficient of the cells. The analytical solution of the Keller-Segel model is then taken as the basis of numerical simulations of interactions between leukocytes and their duration. The mean field interaction force that we derive has a time-space separable form and depends on the chemotaxis sensitivity parameter as well as on the chemokines diffusion coefficient and their degradation rate. All these parameters affect the distribution of the interaction durations. We draw a successful qualitative comparison between simulated data and sets of experimental data for DC-NK cells interaction duration and other kinematic parameters. Remarkably, the predicted percentage of the leukocyte-leukocyte interactions falls in the experimental range and depends (~25% increase upon the chemotactic parameter indicating a non-negligible direct effect of the non-contact interaction on the leukocyte interactions.

  20. Modeling leukocyte-leukocyte non-contact interactions in a lymph node.

    Science.gov (United States)

    Gritti, Nicola; Caccia, Michele; Sironi, Laura; Collini, Maddalena; D'Alfonso, Laura; Granucci, Francesca; Zanoni, Ivan; Chirico, Giuseppe

    2013-01-01

    The interaction among leukocytes is at the basis of the innate and adaptive immune-response and it is largely ascribed to direct cell-cell contacts. However, the exchange of a number of chemical stimuli (chemokines) allows also non-contact interaction during the immunological response. We want here to evaluate the extent of the effect of the non-contact interactions on the observed leukocyte-leukocyte kinematics and their interaction duration. To this aim we adopt a simplified mean field description inspired by the Keller-Segel chemotaxis model, of which we report an analytical solution suited for slowly varying sources of chemokines. Since our focus is on the non-contact interactions, leukocyte-leukocyte contact interactions are simulated only by means of a space dependent friction coefficient of the cells. The analytical solution of the Keller-Segel model is then taken as the basis of numerical simulations of interactions between leukocytes and their duration. The mean field interaction force that we derive has a time-space separable form and depends on the chemotaxis sensitivity parameter as well as on the chemokines diffusion coefficient and their degradation rate. All these parameters affect the distribution of the interaction durations. We draw a successful qualitative comparison between simulated data and sets of experimental data for DC-NK cells interaction duration and other kinematic parameters. Remarkably, the predicted percentage of the leukocyte-leukocyte interactions falls in the experimental range and depends (~25% increase) upon the chemotactic parameter indicating a non-negligible direct effect of the non-contact interaction on the leukocyte interactions.

  1. Highly Sensitive Bulk Silicon Chemical Sensors with Sub-5 nm Thin Charge Inversion Layers.

    Science.gov (United States)

    Fahad, Hossain M; Gupta, Niharika; Han, Rui; Desai, Sujay B; Javey, Ali

    2018-03-27

    There is an increasing demand for mass-producible, low-power gas sensors in a wide variety of industrial and consumer applications. Here, we report chemical-sensitive field-effect-transistors (CS-FETs) based on bulk silicon wafers, wherein an electrostatically confined sub-5 nm thin charge inversion layer is modulated by chemical exposure to achieve a high-sensitivity gas-sensing platform. Using hydrogen sensing as a "litmus" test, we demonstrate large sensor responses (>1000%) to 0.5% H 2 gas, with fast response (<60 s) and recovery times (<120 s) at room temperature and low power (<50 μW). On the basis of these performance metrics as well as standardized benchmarking, we show that bulk silicon CS-FETs offer similar or better sensing performance compared to emerging nanostructures semiconductors while providing a highly scalable and manufacturable platform.

  2. Impact of recess etching and surface treatments on ohmic contacts regrown by molecular-beam epitaxy for AlGaN/GaN high electron mobility transistors

    Energy Technology Data Exchange (ETDEWEB)

    Joglekar, S.; Azize, M.; Palacios, T. [Microsystems Technology Laboratories, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, Massachusetts 02139 (United States); Beeler, M.; Monroy, E. [Université Grenoble-Alpes, 38000 Grenoble (France); CEA Grenoble, INAC-PHELIQS, 38000 Grenoble (France)

    2016-07-25

    Ohmic contacts fabricated by regrowth of n{sup +} GaN are favorable alternatives to metal-stack-based alloyed contacts in GaN-based high electron mobility transistors. In this paper, the influence of reactive ion dry etching prior to regrowth on the contact resistance in AlGaN/GaN devices is discussed. We demonstrate that the dry etch conditions modify the surface band bending, dangling bond density, and the sidewall depletion width, which influences the contact resistance of regrown contacts. The impact of chemical surface treatments performed prior to regrowth is also investigated. The sensitivity of the contact resistance to the surface treatments is found to depend upon the dangling bond density of the sidewall facets exposed after dry etching. A theoretical model has been developed in order to explain the observed trends.

  3. Chemical cross-linking with thiol-cleavable reagents combined with differential mass spectrometric peptide mapping--a novel approach to assess intermolecular protein contacts

    DEFF Research Database (Denmark)

    Bennett, K L; Kussmann, M; Björk, P

    2000-01-01

    The intermolecular contact regions between monomers of the homodimeric DNA binding protein ParR and the interaction between the glycoproteins CD28 and CD80 were investigated using a strategy that combined chemical cross-linking with differential MALDI-MS analyses. ParR dimers were modified in vit...

  4. The pilosebaceous unit—a phthalate-induced pathway to skin sensitization

    International Nuclear Information System (INIS)

    Simonsson, Carl; Stenfeldt, Anna-Lena; Karlberg, Ann-Therese; Ericson, Marica B.; Jonsson, Charlotte A.M.

    2012-01-01

    Allergic contact dermatitis (ACD) is caused by low-molecular weight compounds called haptens. It has been shown that the potency of haptens can depend on the formulation in which they are applied on the skin. Specifically the sensitization potency of isothiocyanates, a group of haptens which can be released from e.g. adhesive tapes and neoprene materials, increases with the presence of phthalates; however, the underlying mechanisms are not clear. A better understanding of the mechanisms governing the potency of haptens is important, e.g. to improve the risk assessment and the formulation of chemicals in consumer products. In this study we have explored phthalate-induced effects on the sensitization potency, skin distribution, and reactivity of fluorescent model isothiocyanate haptens using non-invasive two-photon microscopy to provide new insights regarding vehicle effects in ACD. The data presented in this paper indicate that the sensitization potency of isothiocyanates increases when applied in combination with dibutylphthalate due to a specific uptake via the pilosebaceous units. The results highlight the importance of shunt pathways when evaluating the bioavailability of skin sensitizers. The findings also indicate that vehicle-dependent hapten reactivity towards stratum corneum proteins regulates the bioavailability, and thus the potency, of skin sensitizers. -- Highlights: ► Vehicle effects on sensitization potency were investigated in the LLNA. ► In vivo cutaneous absorption of contact sensitizers was visualized using TPM. ► Sensitizing potency of isothiocyanates depends on the presence of a phthalate. ► Phthalate induced cutaneous absorption via the pilosebaceous units. ► Vehicle-dependent reactivity regulates sensitization potency.

  5. The pilosebaceous unit—a phthalate-induced pathway to skin sensitization

    Energy Technology Data Exchange (ETDEWEB)

    Simonsson, Carl, E-mail: carl.simonsson@chem.gu.se [Department of Chemistry and Molecular Biology, University of Gothenburg, SE-412 96, Gothenburg (Sweden); Stenfeldt, Anna-Lena; Karlberg, Ann-Therese [Department of Chemistry and Molecular Biology, University of Gothenburg, SE-412 96, Gothenburg (Sweden); Ericson, Marica B., E-mail: marica.ericson@physics.gu.se [Department of Physics, University of Gothenburg, SE-412 96, Gothenburg (Sweden); Jonsson, Charlotte A.M. [Department of Chemistry and Molecular Biology, University of Gothenburg, SE-412 96, Gothenburg (Sweden)

    2012-10-01

    Allergic contact dermatitis (ACD) is caused by low-molecular weight compounds called haptens. It has been shown that the potency of haptens can depend on the formulation in which they are applied on the skin. Specifically the sensitization potency of isothiocyanates, a group of haptens which can be released from e.g. adhesive tapes and neoprene materials, increases with the presence of phthalates; however, the underlying mechanisms are not clear. A better understanding of the mechanisms governing the potency of haptens is important, e.g. to improve the risk assessment and the formulation of chemicals in consumer products. In this study we have explored phthalate-induced effects on the sensitization potency, skin distribution, and reactivity of fluorescent model isothiocyanate haptens using non-invasive two-photon microscopy to provide new insights regarding vehicle effects in ACD. The data presented in this paper indicate that the sensitization potency of isothiocyanates increases when applied in combination with dibutylphthalate due to a specific uptake via the pilosebaceous units. The results highlight the importance of shunt pathways when evaluating the bioavailability of skin sensitizers. The findings also indicate that vehicle-dependent hapten reactivity towards stratum corneum proteins regulates the bioavailability, and thus the potency, of skin sensitizers. -- Highlights: ► Vehicle effects on sensitization potency were investigated in the LLNA. ► In vivo cutaneous absorption of contact sensitizers was visualized using TPM. ► Sensitizing potency of isothiocyanates depends on the presence of a phthalate. ► Phthalate induced cutaneous absorption via the pilosebaceous units. ► Vehicle-dependent reactivity regulates sensitization potency.

  6. The Influences of Face Inversion and Facial Expression on Sensitivity to Eye Contact in High-Functioning Adults with Autism Spectrum Disorders

    Science.gov (United States)

    Vida, Mark D.; Maurer, Daphne; Calder, Andrew J.; Rhodes, Gillian; Walsh, Jennifer A.; Pachai, Matthew V.; Rutherford, M. D.

    2013-01-01

    We examined the influences of face inversion and facial expression on sensitivity to eye contact in high-functioning adults with and without an autism spectrum disorder (ASD). Participants judged the direction of gaze of angry, fearful, and neutral faces. In the typical group only, the range of directions of gaze leading to the perception of eye…

  7. Dendritic cells and skin sensitization: Biological roles and uses in hazard identification

    International Nuclear Information System (INIS)

    Ryan, Cindy A.; Kimber, Ian; Basketter, David A.; Pallardy, Marc; Gildea, Lucy A.; Gerberick, G. Frank

    2007-01-01

    Recent advances have been made in our understanding of the roles played by cutaneous dendritic cells (DCs) in the induction of contact allergy. A number of associated changes in epidermal Langerhans cell phenotype and function required for effective skin sensitization are providing the foundations for the development of cellular assays (using DC and DC-like cells) for skin sensitization hazard identification. These alternative approaches to the identification and characterization of skin sensitizing chemicals were the focus of a Workshop entitled 'Dendritic Cells and Skin Sensitization: Biological Roles and Uses in Hazard Identification' that was given at the annual Society of Toxicology meeting held March 6-9, 2006 in San Diego, California. This paper reports information that was presented during the Workshop

  8. Further development of LLNA:DAE method as stand-alone skin-sensitization testing method and applied for evaluation of relative skin-sensitizing potency between chemicals.

    Science.gov (United States)

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Itagaki, Hiroshi

    2015-04-01

    To date, there has been no well-established local lymph node assay (LLNA) that includes an elicitation phase. Therefore, we developed a modified local lymph node assay with an elicitation phase (LLNA:DAE) to discriminate true skin sensitizers from chemicals that gave borderline positive results and previously reported this assay. To develop the LLNA:DAE method as a useful stand-alone testing method, we investigated the complete procedure for the LLNA:DAE method using hexyl cinnamic aldehyde (HCA), isoeugenol, and 2,4-dinitrochlorobenzene (DNCB) as test compounds. We defined the LLNA:DAE procedure as follows: in the dose-finding test, four concentrations of chemical applied to dorsum of the right ear on days 1, 2, and 3 and dorsum of both ears on day 10. Ear thickness and skin irritation score were measured on days 1, 3, 5, 10, and 12. Local lymph nodes were excised and weighed on day 12. The test dose for the primary LLNA:DAE study was selected as the dose that gave the highest left ear lymph node weight in the dose-finding study, or the lowest dose that produced a left ear lymph node of over 4 mg. This procedure was validated using nine different chemicals. Furthermore, qualitative relationship was observed between the degree of elicitation response in the left ear lymph node and the skin sensitizing potency of 32 chemicals tested in this study and the previous study. These results indicated that LLNA:DAE method was as first LLNA method that was able to evaluate the skin sensitizing potential and potency in elicitation response.

  9. Psychogenic chemical sensitivity: psychogenic pseudoseizures elicited by provocation challenges with fragrances.

    Science.gov (United States)

    Staudenmayer, H; Kramer, R E

    1999-08-01

    A middle-aged woman with a 10-year history of disability attributed to chemical sensitivities complained that exposure to specific fragrances immediately elicited seizures. Video-EEG monitoring was performed in a hospital neurodiagnostic laboratory during provocative challenge studies employing fragrances identified by the patient as reliably inducing symptoms. The baseline clinical EEG was normal. Immediately after each provocation with air deodorant and perfume, she consistently showed both generalized tonic/clonic and multifocal myoclonic jerking, at times was nonresponsive, spoke with slurred speech, and complained of right-sided paralysis and lethargy. None of these events were associated with any EEG abnormalities. Psychological assessment (MMPI-2, MCMI-II) revealed personality traits that predisposed her to somatization and beliefs about environmental sensitivities. The convulsions were a manifestation of psychogenic pseudoseizures that had been iatrogenically reinforced.

  10. Thermal and chemical treatment of polymer optical fiber Bragg grating sensors for enhanced mechanical sensitivity

    DEFF Research Database (Denmark)

    Pospori, Andreas; Marques, C. A. F.; Saez-Rodriguez, D.

    2017-01-01

    An investigation of the thermal annealing effects on the strain, stress, and force sensitivities of polymer optical fiber Bragg grating sensors is performed. We demonstrate for the first time that the fiber annealing can enhance both stress and force sensitivities of Bragg grating sensors......, with the possible cause being the molecular relaxation of the polymer when fiber is raised above the β-transition temperature. A simple, cost-effective, but well controlled method for fiber annealing is also presented in this work. In addition, the effects of chemical etching on the strain, stress, and force...... sensitivities have been investigated. Results show that fiber etching too can increase the force sensitivity, and it can also affect the strain and stress sensitivities of the Bragg grating sensors....

  11. Thermal and chemical treatment of polymer optical fiber Bragg grating sensors for enhanced mechanical sensitivity

    Science.gov (United States)

    Pospori, A.; Marques, C. A. F.; Sáez-Rodríguez, D.; Nielsen, K.; Bang, O.; Webb, D. J.

    2017-07-01

    An investigation of the thermal annealing effects on the strain, stress, and force sensitivities of polymer optical fiber Bragg grating sensors is performed. We demonstrate for the first time that the fiber annealing can enhance both stress and force sensitivities of Bragg grating sensors, with the possible cause being the molecular relaxation of the polymer when fiber is raised above the β -transition temperature. A simple, cost-effective, but well controlled method for fiber annealing is also presented in this work. In addition, the effects of chemical etching on the strain, stress, and force sensitivities have been investigated. Results show that fiber etching too can increase the force sensitivity, and it can also affect the strain and stress sensitivities of the Bragg grating sensors.

  12. Occupation, exposure to chemicals, sensitizing agents, and risk of multiple myeloma in Sweden.

    Science.gov (United States)

    Lope, Virginia; Pérez-Gómez, Beatriz; Aragonés, Nuria; López-Abente, Gonzalo; Gustavsson, Per; Plato, Nils; Zock, Jan-Paul; Pollán, Marina

    2008-11-01

    This study sought to identify occupations with high incidence of multiple myeloma and to investigate possible excess risk associated with occupational exposure to chemicals and sensitizing agents in Sweden. A historical cohort of 2,992,166 workers was followed up (1971--1989) through record linkage with the National Cancer and Death Registries. For each job category, age and period standardized incidence ratios and age and period adjusted relative risks of multiple myeloma were calculated using Poisson models. Exposure to chemicals and to sensitizing agents was also assessed using two job-exposure matrices. Men and women were analyzed separately. During follow-up, 3,127 and 1,282 myelomas were diagnosed in men and women, respectively. In men, excess risk was detected among working proprietors, agricultural, horticultural and forestry enterprisers, bakers and pastry cooks, dental technicians, stone cutters/carvers, and prison/reformatory officials. In women, this excess was observed among attendants in psychiatric care, metal workers, bakers and pastry cooks, and paper/paperboard product workers. Workers, particularly bakers and pastry cooks, exposed to high molecular weight sensitizing agents registered an excess risk of over 40% across the sexes. Occasional, although intense, exposure to pesticides was also associated with risk of myeloma in our cohort. Our study supports a possible etiologic role for farming and use of pesticides in myeloma risk. The high incidence found in both female and male bakers and pastry cooks has not been described previously. Further research is required to assess the influence of high molecular weight sensitizing agents on risk of multiple myeloma.

  13. New aspects in allergic contact dermatitis

    DEFF Research Database (Denmark)

    Mørtz, Charlotte G; Andersen, Klaus Ejner

    2008-01-01

    PURPOSE OF REVIEW: To give selected new information on contact allergy and allergic contact dermatitis with focus on diagnostic procedures and pitfalls. RECENT FINDINGS: Recent studies dealing with common contact allergens have improved our understanding of the relationship between positive patch...... contact dermatitis. The main culprits include fragrance chemicals, preservatives, and hair dyes. We are all more or less exposed to cosmetics and topical drugs on a daily basis. The labelling requirements given in the Cosmetics Directive is of great help in tracing the causative allergenic ingredients...... tests and the clinical interpretation and consequences for the patient. SUMMARY: Nickel allergy is still the most common contact allergy in Europe in spite of full implementation of the EU Nickel Directive in 2001. Contact allergens in cosmetics and topical drugs are another common cause of allergic...

  14. Toxicity testing and chemical analyses of recycled fibre-based paper for food contact

    DEFF Research Database (Denmark)

    Binderup, Mona-Lise; Pedersen, Gitte Alsing; Vinggaard, Anne

    2002-01-01

    of different qualities as food-contact materials and to Perform a preliminary evaluation of their suitability from a safety point of view, and, second, to evaluate the use of different in vitro toxicity tests for screening of paper and board. Paper produced from three different categories of recycled fibres (B...... of the paper products were extracted with either 99% ethanol or water. Potential migrants in the extracts were identified and semiquantified by GC-1R-MS or GC-HRMS. In parallel to the chemical analyses, a battery of four different in vitro toxicity tests with different endpoints were applied to the same...... was less cytotoxic than the extracts prepared from paper made from recycled fibres, and extracts prepared from C was the most cytotoxic. None of the extracts showed mutagenic activity No conclusion about the oestrogenic activity could be made, because all extracts were cytotoxic to the test organism (yeast...

  15. Changes in the pattern of sensitization to common contact allergens in denmark between 1985-86 and 1997-98, with a special view to the effect of preventive strategies

    DEFF Research Database (Denmark)

    Johansen, J d; Menné, T; Christophersen, J

    2000-01-01

    sensitization during that period, and particular areas of concern are identified. Members of the Danish Contact Dermatitis Group collected patch-test results from consecutive eczema patients as well as information about exposures and demographic variables over a 6-month period in 1985-86. The investigation......The objective of the present study is to describe any changes in the prevalence of sensitization to common contact allergens in patch-tested patients over a 12-year period. Attention is given to possible effects of preventive strategies introduced in Denmark regarding nickel and chromate...... was repeated in 1997-98 in the same clinics, at the same time of year, using identical methods and patch-test substances, including nickel sulphate 5%, potassium dichromate 0.5% and fragrance mix 8%. Nickel was the most common contact allergen in both study periods, followed by the fragrance mix. In children 0...

  16. Development of LLNA:DAE: a new local lymph node assay that includes the elicitation phase, discriminates borderline-positive chemicals, and is useful for cross-sensitization testing.

    Science.gov (United States)

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Itagaki, Hiroshi

    2014-02-01

    We developed a new local lymph node assay (LLNA) that includes the elicitation phase termed LLNA:DAE for discrimination of borderline-positive chemicals as classified by the LLNA modified by Daicel based on ATP content (LLNA:DA) and for cross-sensitization testing. Although the LLNA:DA method could help identify skin sensitizers, some skin irritants classified as non-sensitizers by the LLNA were classified as borderline positive. In addition, the evaluation for the cross-sensitization potential between chemicals was impossible. In the LLNA:DAE procedure, test group of mice received four applications of chemicals on the dorsum of the right ear for induction and one application on the dorsum of the left ear for elicitation. Control group of mice received one chemical application on the dorsum of the left ear. We evaluated the sensitizing potential by comparing the weights of the lymph nodes from the left ears between the two groups. The results of using the LLNA:DAE method to examine 24 chemicals, which contained borderline-positive chemicals, were consistent with those from the LLNA method, except for nickel chloride (NiCl2). Two chemical pairs, 2,4-dinitrochlorobenzene (DNCB) with 2,4-dinitrofluorobenzene (DNFB) and hydroquinone (HQ) with p-benzoquinone (p-BQ), showed clear cross-sensitization with each other, while another chemical pair, DNFB with hexylcinnamic aldehyde (HCA) did not. Taken together, our results suggest that the LLNA:DAE method is useful for discriminating borderline-positive chemicals and for determining chemical cross-sensitization.

  17. [Contact allergy to henna tattoos].

    Science.gov (United States)

    Steinkjer, Bjarte; Stangeland, Katarina Zak; Mikkelsen, Carsten Sauer

    2011-03-18

    Tattoos with henna colours have become very popular and the prevalence of contact allergy seems to increase. This is a short review article based on our own clinical experience and literature identified through a search in PubMed with the words "henna", "paraphenylendiamin" and "allergic contact dermatitis." A case report is included. It is well documented that many experience skin reactions after henna tattoos. The cause is almost always contact allergy to the azo compound paraphenylendiamin, which is added to speed up the process and make the colour darker. Most people, including children, get henna tattoos during vacations in Asia or the Mediterranean. Established contact allergy is permanent. Many hair-colour products contain paraphenylendiamin, and persons with contact allergy against the product may develop a very strong contact allergic eczema by use of such substances. Acute reactions are treated with local cortisone products, or with systemic steroids. Cross reaction to substances with a similar chemical structure may occur. Tattoos with paraphenylendiamin-containing henna colours should be avoided.

  18. Evaluating use stage exposure to food contact materials in a LCA framework

    DEFF Research Database (Denmark)

    Ernstoff, Alexi; Jolliet, Olivier; Fantke, Peter

    2015-01-01

    We present novel methods to incorporate exposure to chemicals within food contact materials (FCM) (e.g. packaging) into life cycle impact assessment (LCIA). Chemical migration into food is modeled as a function of contact temperature, time, and various chemical, FCM, and food properties. In order...... in a way compatible with intake fraction, iF, a metric traditionally used in LCIA. The model predicts PiF increases with temperature and for compounds with lower octanol-water partition coefficients within more permeable materials which are in contact with foods with high ethanol equivalencies (fatty foods)....

  19. Experimental photoallergic contact dermatitis: a mouse model

    International Nuclear Information System (INIS)

    Maguire, H.C. Jr.; Kaidbey, K.

    1982-01-01

    We have induced photoallergic contact dermatitis in mice to 3,3',4',5 tetrachlorosalicylanilide (TCSA), chlorpromazine and 6-methylcoumarin. These compounds are known to produce photoallergic contact dermatitis in humans. The photoallergic contact dermatitis reaction in the mouse is immunologically specific viz. mice photosensitized to TCSA react, by photochallenge, to that compound and not to chlorpromazine, and conversely. The reaction requires UVA at both sensitization and challenge. It appears to be T-cell mediated in that it can be passively transferred to syngeneic mice by lymph node cells from actively sensitized mice, the histology of the reactions resembles that of classic allergic contact dermatitis in mice, challenge reactions are seen at 24 but not at 4 hr, and photoallergic contact dermatitis can be induced in B-cell deficient mice. The availability of a mouse model for the study of photo-ACD will facilitate the identification of pertinent control mechanisms and may aid in the management of the disease. It is likely that a bioassay for photoallergens of humans can be based on this mouse model

  20. A genomic biomarker signature can predict skin sensitizers using a cell-based in vitro alternative to animal tests

    Directory of Open Access Journals (Sweden)

    Albrekt Ann-Sofie

    2011-08-01

    Full Text Available Abstract Background Allergic contact dermatitis is an inflammatory skin disease that affects a significant proportion of the population. This disease is caused by an adverse immune response towards chemical haptens, and leads to a substantial economic burden for society. Current test of sensitizing chemicals rely on animal experimentation. New legislations on the registration and use of chemicals within pharmaceutical and cosmetic industries have stimulated significant research efforts to develop alternative, human cell-based assays for the prediction of sensitization. The aim is to replace animal experiments with in vitro tests displaying a higher predictive power. Results We have developed a novel cell-based assay for the prediction of sensitizing chemicals. By analyzing the transcriptome of the human cell line MUTZ-3 after 24 h stimulation, using 20 different sensitizing chemicals, 20 non-sensitizing chemicals and vehicle controls, we have identified a biomarker signature of 200 genes with potent discriminatory ability. Using a Support Vector Machine for supervised classification, the prediction performance of the assay revealed an area under the ROC curve of 0.98. In addition, categorizing the chemicals according to the LLNA assay, this gene signature could also predict sensitizing potency. The identified markers are involved in biological pathways with immunological relevant functions, which can shed light on the process of human sensitization. Conclusions A gene signature predicting sensitization, using a human cell line in vitro, has been identified. This simple and robust cell-based assay has the potential to completely replace or drastically reduce the utilization of test systems based on experimental animals. Being based on human biology, the assay is proposed to be more accurate for predicting sensitization in humans, than the traditional animal-based tests.

  1. A genomic biomarker signature can predict skin sensitizers using a cell-based in vitro alternative to animal tests

    Science.gov (United States)

    2011-01-01

    Background Allergic contact dermatitis is an inflammatory skin disease that affects a significant proportion of the population. This disease is caused by an adverse immune response towards chemical haptens, and leads to a substantial economic burden for society. Current test of sensitizing chemicals rely on animal experimentation. New legislations on the registration and use of chemicals within pharmaceutical and cosmetic industries have stimulated significant research efforts to develop alternative, human cell-based assays for the prediction of sensitization. The aim is to replace animal experiments with in vitro tests displaying a higher predictive power. Results We have developed a novel cell-based assay for the prediction of sensitizing chemicals. By analyzing the transcriptome of the human cell line MUTZ-3 after 24 h stimulation, using 20 different sensitizing chemicals, 20 non-sensitizing chemicals and vehicle controls, we have identified a biomarker signature of 200 genes with potent discriminatory ability. Using a Support Vector Machine for supervised classification, the prediction performance of the assay revealed an area under the ROC curve of 0.98. In addition, categorizing the chemicals according to the LLNA assay, this gene signature could also predict sensitizing potency. The identified markers are involved in biological pathways with immunological relevant functions, which can shed light on the process of human sensitization. Conclusions A gene signature predicting sensitization, using a human cell line in vitro, has been identified. This simple and robust cell-based assay has the potential to completely replace or drastically reduce the utilization of test systems based on experimental animals. Being based on human biology, the assay is proposed to be more accurate for predicting sensitization in humans, than the traditional animal-based tests. PMID:21824406

  2. Preparation and investigation of burried metal/molecule contact interfaces with surface sensitive methods; Praeparation und Untersuchung verborgener Metall/Molekuel-Kontaktgrenzflaechen mit oberflaechensensitiven Methoden

    Energy Technology Data Exchange (ETDEWEB)

    Vrdoljak, Pavo

    2011-05-13

    The present thesis establishes an optimised concept of a delamination technique suitable for ultra high vacuum (UHV) with which model systems of buried interfaces were made accessible for surface sensitive methods which were applied to investigate their electronic and topographical properties. A primary focus of this work is on the question how buried interfaces could be accessed successfully for surface sensitive methods using buried metal/NTCDA and metal/PTCDA interfaces as model systems. Contacts of approximately 10 x 15 mm{sup 2} in size were accessed. The second focus of the thesis is on the investigation of the electronical and topographical properties of the buried interfaces, for which some similarities between delaminated metal (Au,Ag)/ PTCDA- and Ag/NTCDA interfaces were found: After the delamination of top-contacts there were inhomogeneous layers of molecules on the metal contacts. Whereas PTCDA covered metal contacts had thicker molecular layers (4-5 ML PTCDA on Ag), NTCDA covered contacts showed only one monolayer coverage over large areas of at least 2 mm in diameter. Regions with multilayer coverage showed smooth surfaces whereas metal surfaces showed a fissured, meander-like and rough surface. Both contact systems also had in common that the adhesive made PES investigations of valence states very difficult. Furthermore, it was possible to thin out the molecular layers thermally but afterwards no valence states could be measured. Investigating in-situ delaminated buried interfaces, the focus was on metal (Au,Ag)/PTCDA interfaces first. The molecular layers could be successfully desorbed thermally at 260 C to 1-3 monolayers so that valence states were investigated. The spectra of the in-situ delaminated and thermally desorbed Ag/PTCDA contact were noticeably broadened so that the positions of HOMO and FLUMO could only be estimated at 1.9 eV and 0.7 eV, respectively. Additionally, interfaces of Ag/NTCDA contacts were investigated. With UPS it was found

  3. Use of an ex vivo local lymph node assay to assess contact hypersensitivity potential.

    Science.gov (United States)

    Piccotti, Joseph R; Kawabata, Thomas T

    2008-07-01

    The local lymph node assay (LLNA) is used to assess the contact hypersensitivity potential of compounds. In the standard assay, mice are treated topically with test compound to the dorsum of both ears on Days 1-3. The induction of a hypersensitivity response is assessed on Day 6 by injecting [(3)H]-thymidine into a tail vein and measuring thymidine incorporation into DNA of lymph node cells draining the ears. The ex vivo LLNA is conducted similarly except lymphocyte proliferation is assessed after in vitro incubation of lymph node cells with [(3)H]-thymidine, which significantly reduces the amount of radioactive waste. The current study tested the use of this approach for hazard assessment of contact hypersensitivity and to estimate allergenic potency. Female BALB/c mice were treated on Days 1-3 with two nonsensitizers (4' -methoxyacetophenone, diethyl phthalate), three weak sensitizers (hydroxycitronellal, eugenol, citral), one weak-to-moderate sensitizer (hexylcinnamic aldehyde), two moderate sensitizers (isoeugenol, phenyl benzoate), and one strong sensitizer (dinitrochlorobenzene). On Day 6, isolated lymph node cells were incubated overnight with [(3)H]-thymidine and thymidine incorporation was measured by liquid scintillation spectrophotometry. The ex vivo LLNA accurately distinguished the contact sensitizers from the nonsensitizing chemicals, and correctly ranked the relative potency of the compounds tested. The EC3 values, i.e., the effective concentration of test substance needed to induce a stimulation index of 3, were as follows: 4' -methoxyacetophenone (> 50%), diethyl phthalate (> 50%), hydroxycitronellal (20.4%), eugenol (13.6%), citral (8.9%), isoeugenol (3.8%), hexylcinnamic aldehyde (2.7%), phenyl benzoate (2%), and dinitrochlorobenzene (0.02%). In addition, low inter-animal and inter-experiment variability was seen with 25% hexyl-cinnamic aldehyde (assay positive control). The results of the ex vivo LLNA in the current study were consistent with

  4. Chemically Designed Metallic/Insulating Hybrid Nanostructures with Silver Nanocrystals for Highly Sensitive Wearable Pressure Sensors.

    Science.gov (United States)

    Kim, Haneun; Lee, Seung-Wook; Joh, Hyungmok; Seong, Mingi; Lee, Woo Seok; Kang, Min Su; Pyo, Jun Beom; Oh, Soong Ju

    2018-01-10

    With the increase in interest in wearable tactile pressure sensors for e-skin, researches to make nanostructures to achieve high sensitivity have been actively conducted. However, limitations such as complex fabrication processes using expensive equipment still exist. Herein, simple lithography-free techniques to develop pyramid-like metal/insulator hybrid nanostructures utilizing nanocrystals (NCs) are demonstrated. Ligand-exchanged and unexchanged silver NC thin films are used as metallic and insulating components, respectively. The interfaces of each NC layer are chemically engineered to create discontinuous insulating layers, i.e., spacers for improved sensitivity, and eventually to realize fully solution-processed pressure sensors. Device performance analysis with structural, chemical, and electronic characterization and conductive atomic force microscopy study reveals that hybrid nanostructure based pressure sensor shows an enhanced sensitivity of higher than 500 kPa -1 , reliability, and low power consumption with a wide range of pressure sensing. Nano-/micro-hierarchical structures are also designed by combining hybrid nanostructures with conventional microstructures, exhibiting further enhanced sensing range and achieving a record sensitivity of 2.72 × 10 4 kPa -1 . Finally, all-solution-processed pressure sensor arrays with high pixel density, capable of detecting delicate signals with high spatial selectivity much better than the human tactile threshold, are introduced.

  5. Noise sensitivity: Symptoms, health status, illness behavior and co-occurring environmental sensitivities

    Energy Technology Data Exchange (ETDEWEB)

    Baliatsas, Christos, E-mail: c.baliatsas@nivel.nl [Netherlands Institute for Health Services Research (NIVEL), Utrecht (Netherlands); Kamp, Irene van, E-mail: irene.van.kamp@rivm.nl [National Institute for Public Health and the Environment (RIVM), Bilthoven (Netherlands); Swart, Wim, E-mail: wim.swart@rivm.nl [National Institute for Public Health and the Environment (RIVM), Bilthoven (Netherlands); Hooiveld, Mariëtte, E-mail: m.hooiveld@nivel.nl [Netherlands Institute for Health Services Research (NIVEL), Utrecht (Netherlands); Yzermans, Joris, E-mail: J.Yzermans@nivel.nl [Netherlands Institute for Health Services Research (NIVEL), Utrecht (Netherlands)

    2016-10-15

    Epidemiological evidence on the symptomatic profile, health status and illness behavior of people with subjective sensitivity to noise is still scarce. Also, it is unknown to what extent noise sensitivity co-occurs with other environmental sensitivities such as multi-chemical sensitivity and sensitivity to electromagnetic fields (EMF). A cross-sectional study performed in the Netherlands, combining self-administered questionnaires and electronic medical records of non-specific symptoms (NSS) registered by general practitioners (GP) allowed us to explore this further. The study sample consisted of 5806 participants, drawn from 21 general practices. Among participants, 722 (12.5%) responded “absolutely agree” to the statement “I am sensitive to noise”, comprising the high noise-sensitive (HNS) group. Compared to the rest of the sample, people in the HNS group reported significantly higher scores on number and duration of self-reported NSS, increased psychological distress, decreased sleep quality and general health, more negative symptom perceptions and higher prevalence of healthcare contacts, GP-registered NSS and prescriptions for antidepressants and benzodiazepines. These results remained robust after adjustment for demographic, residential and lifestyle characteristics, objectively measured nocturnal noise exposure from road-traffic and GP-registered morbidity. Co-occurrence rates with other environmental sensitivities varied between 9% and 50%. Individuals with self-declared sensitivity to noise are characterized by high prevalence of multiple NSS, poorer health status and increased illness behavior independently of noise exposure levels. Findings support the notion that different types of environmental sensitivities partly overlap. - Highlights: • People with self-reported noise sensitivity experience multiple non-specific symptoms. • They also report comparatively poorer health and increased illness behavior. • Co-occurrence with other

  6. Noise sensitivity: Symptoms, health status, illness behavior and co-occurring environmental sensitivities

    International Nuclear Information System (INIS)

    Baliatsas, Christos; Kamp, Irene van; Swart, Wim; Hooiveld, Mariëtte; Yzermans, Joris

    2016-01-01

    Epidemiological evidence on the symptomatic profile, health status and illness behavior of people with subjective sensitivity to noise is still scarce. Also, it is unknown to what extent noise sensitivity co-occurs with other environmental sensitivities such as multi-chemical sensitivity and sensitivity to electromagnetic fields (EMF). A cross-sectional study performed in the Netherlands, combining self-administered questionnaires and electronic medical records of non-specific symptoms (NSS) registered by general practitioners (GP) allowed us to explore this further. The study sample consisted of 5806 participants, drawn from 21 general practices. Among participants, 722 (12.5%) responded “absolutely agree” to the statement “I am sensitive to noise”, comprising the high noise-sensitive (HNS) group. Compared to the rest of the sample, people in the HNS group reported significantly higher scores on number and duration of self-reported NSS, increased psychological distress, decreased sleep quality and general health, more negative symptom perceptions and higher prevalence of healthcare contacts, GP-registered NSS and prescriptions for antidepressants and benzodiazepines. These results remained robust after adjustment for demographic, residential and lifestyle characteristics, objectively measured nocturnal noise exposure from road-traffic and GP-registered morbidity. Co-occurrence rates with other environmental sensitivities varied between 9% and 50%. Individuals with self-declared sensitivity to noise are characterized by high prevalence of multiple NSS, poorer health status and increased illness behavior independently of noise exposure levels. Findings support the notion that different types of environmental sensitivities partly overlap. - Highlights: • People with self-reported noise sensitivity experience multiple non-specific symptoms. • They also report comparatively poorer health and increased illness behavior. • Co-occurrence with other

  7. Experimental assessment of the sensitiveness of an electrochemical oscillator towards chemical perturbations.

    Directory of Open Access Journals (Sweden)

    Graziela C A Ferreira

    Full Text Available In this study we address the problem of the response of a (electrochemical oscillator towards chemical perturbations of different magnitudes. The chemical perturbation was achieved by addition of distinct amounts of trifluoromethanesulfonate (TFMSA, a rather stable and non-specifically adsorbing anion, and the system under investigation was the methanol electro-oxidation reaction under both stationary and oscillatory regimes. Increasing the anion concentration resulted in a decrease in the reaction rates of methanol oxidation and a general decrease in the parameter window where oscillations occurred. Furthermore, the addition of TFMSA was found to decrease the induction period and the total duration of oscillations. The mechanism underlying these observations was derived mathematically and revealed that inhibition in the methanol oxidation through blockage of active sites was found to further accelerate the intrinsic non-stationarity of the unperturbed system. Altogether, the presented results are among the few concerning the experimental assessment of the sensitiveness of an oscillator towards chemical perturbations. The universal nature of the complex chemical oscillator investigated here might be used for reference when studying the dynamics of other less accessible perturbed networks of (biochemical reactions.

  8. [Assessment of the sensitizing potency of cosmetic ingredients and commodities. How will the ingredients of cosmetics and commodities be tested in Europe today and tomorrow?].

    Science.gov (United States)

    Peiser, M; Platzek, T; Luch, A

    2012-03-01

    Cosmetics and certain commodities are applied or used by consumers directly on the skin. Creams may remain on the skin for longer periods, hair is dyed multiple times per year, nickel ions can be released from studs and piercings in areas of skin damage or migrate from toy materials into the skin of children. Accordingly, using or handling such products always entails a risk for developing a contact allergy. Moreover, daily usage and repeated contacts to certain cosmetics and commodities might lead to repeated elicitation of contact eczema in people already sensitized against allergenic ingredients. Unfortunately, contact allergy is not curable. For the assessment of the allergenic potential of chemicals, only testing based on animal experiments was available in the past. In 2003, the 7(th) amendment of the Cosmetics Directive 76/768/EWG laid down a ban on animal testing of cosmetic ingredients and from 2013 a general marketing ban of such products as well. Therefore, the development and validation of non-animal methods for assessing the toxicological endpoint sensitization/allergenic potency of chemicals is a major task for the years ahead and remains equally a challenge for industry and regulatory agencies.

  9. Allergic contact dermatitis in childrenwhich factors are relevant? (review of the literature)

    DEFF Research Database (Denmark)

    de Waard-van der Spek, Flora B; Andersen, Klaus Ejner; Darsow, Ulf

    2013-01-01

    defined dermatitis on the lower legs. Clinical polymorphism of contact dermatitis to clothing may cause difficulties in diagnosing textile dermatitis. Toys are another potentially source of hapten exposure in children, especially from toy-cosmetic products such as perfumes, lipstick and eye shadow......Allergic Contact Dermatitis (ACD) in children is increasing. Sensitization to contact allergens can start in early infancy. The epidermal barrier is crucial for the development of sensitization and elicitation of ACD. Factors that may influence the onset of sensitization in children are atopic...... dermatitis, skin barrier defects and intense or repetitive contact with allergens. Topical treatment of ACD is associated with cutaneous sensitization, although the prevalence is not high. ACD because of haptens in shoes or shin guards should be considered in cases of persistent foot eruptions or sharply...

  10. Controlled assembly of organic whispering-gallery-mode microlasers as highly sensitive chemical vapor sensors.

    Science.gov (United States)

    Gao, Miaomiao; Wei, Cong; Lin, Xianqing; Liu, Yuan; Hu, Fengqin; Zhao, Yong Sheng

    2017-03-09

    We demonstrate the fabrication of organic high Q active whispering-gallery-mode (WGM) resonators from π-conjugated polymer by a controlled emulsion-solvent-evaporation method, which can simultaneously provide optical gain and act as an effective resonant cavity. By measuring the shift of their lasing modes on exposure to organic vapor, we successfully monitored the slight concentration variation in the chemical gas. These microlaser sensors demonstrated high detection sensitivity and good signal repeatability under continuous chemical gas treatments. The results offer an effective strategy to design miniaturized optical sensors.

  11. Association between Contact allergy and Psoriasis

    DEFF Research Database (Denmark)

    Bangsgaard, Nannie

    2011-01-01

    6. SUMMERY 6.1 Summery in English Allergic contact dermatitis (ACD) and psoriasis are the two most prevalent skin diseases in the western world. ACD is the clinical manifestation of contact allergy. Contact allergy and psoriasis are both due to inflammatory mechanisms involving the innate...... and adaptive immune system. Psoriasis is conceived to be an autoimmune disease. Recent studies have suggested an inverse relation between contact allergy and autoimmune diseases. The association between contact allergy and psoriasis could reveal mechanistic insights into both inflammatory processes....... The overall aim of this PhD study was to investigate the association between contact allergy and autoimmune disease, with focus on psoriasis. The work was done in three study parts. Part I Epidemiological studies. Part II Sensitization study and Part III Experimental studies. In part I the association between...

  12. Non-animal sensitization testing: state-of-the-art.

    Science.gov (United States)

    Vandebriel, Rob J; van Loveren, Henk

    2010-05-01

    Predictive tests to identify the sensitizing properties of chemicals are carried out using animals. In the European Union timelines for phasing out many standard animal tests were established for cosmetics. Following this policy, the new European Chemicals Legislation (REACH) favors alternative methods, if validated and appropriate. In this review the authors aim to provide a state-of-the art overview of alternative methods (in silico, in chemico, and in vitro) to identify contact and respiratory sensitizing capacity and in some occasions give a measure of potency. The past few years have seen major advances in QSAR (quantitative structure-activity relationship) models where especially mechanism-based models have great potential, peptide reactivity assays where multiple parameters can be measured simultaneously, providing a more complete reactivity profile, and cell-based assays. Several cell-based assays are in development, not only using different cell types, but also several specifically developed assays such as three-dimenionally (3D)-reconstituted skin models, an antioxidant response reporter assay, determination of signaling pathways, and gene profiling. Some of these assays show relatively high sensitivity and specificity for a large number of sensitizers and should enter validation (or are indeed entering this process). Integrating multiple assays in a decision tree or integrated testing system is a next step, but has yet to be developed. Adequate risk assessment, however, is likely to require significantly more time and efforts.

  13. Oil Contact Angles in a Water-Decane-Silicon Dioxide System: Effects of Surface Charge.

    Science.gov (United States)

    Xu, Shijing; Wang, Jingyao; Wu, Jiazhong; Liu, Qingjie; Sun, Chengzhen; Bai, Bofeng

    2018-04-19

    Oil wettability in the water-oil-rock systems is very sensitive to the evolution of surface charges on the rock surfaces induced by the adsorption of ions and other chemical agents in water flooding. Through a set of large-scale molecular dynamics simulations, we reveal the effects of surface charge on the oil contact angles in an ideal water-decane-silicon dioxide system. The results show that the contact angles of oil nano-droplets have a great dependence on the surface charges. As the surface charge density exceeds a critical value of 0.992 e/nm 2 , the contact angle reaches up to 78.8° and the water-wet state is very apparent. The variation of contact angles can be confirmed from the number density distributions of oil molecules. With increasing the surface charge density, the adsorption of oil molecules weakens and the contact areas between nano-droplets and silicon dioxide surface are reduced. In addition, the number density distributions, RDF distributions, and molecular orientations indicate that the oil molecules are adsorbed on the silicon dioxide surface layer-by-layer with an orientation parallel to the surface. However, the layered structure of oil molecules near the silicon dioxide surface becomes more and more obscure at higher surface charge densities.

  14. Sensitivity enhancement by multiple-contact cross-polarization under magic-angle spinning.

    Science.gov (United States)

    Raya, J; Hirschinger, J

    2017-08-01

    Multiple-contact cross-polarization (MC-CP) is applied to powder samples of ferrocene and l-alanine under magic-angle spinning (MAS) conditions. The method is described analytically through the density matrix formalism. The combination of a two-step memory function approach and the Anderson-Weiss approximation is found to be particularly useful to derive approximate analytical solutions for single-contact Hartmann-Hahn CP (HHCP) and MC-CP dynamics under MAS. We show that the MC-CP sequence requiring no pulse-shape optimization yields higher polarizations at short contact times than optimized adiabatic passage through the HH condition CP (APHH-CP) when the MAS frequency is comparable to the heteronuclear dipolar coupling, i.e., when APHH-CP through a single sideband matching condition is impossible or difficult to perform. It is also shown that the MC-CP sideband HH conditions are generally much broader than for single-contact HHCP and that efficient polarization transfer at the centerband HH condition can be reintroduced by rotor-asynchronous multiple equilibrations-re-equilibrations with the proton spin bath. Boundary conditions for the successful use of the MC-CP experiment when relying on spin-lattice relaxation for repolarization are also examined. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Monitoring contact sensitization to p-phenylenediamine (PPD) by patch testing with PPD 0.3% in petrolatum.

    Science.gov (United States)

    Geier, Johannes; Ballmer-Weber, Barbara K; Dickel, Heinrich; Frosch, Peter J; Bircher, Andreas; Weisshaar, Elke; Hillen, Uwe

    2013-07-01

    Being a contact allergen of general relevance, p-phenylenediamine (PPD) is patch tested in the baseline series. However, PPD 1% in petrolatum may actively sensitize. Patch testing with PPD at 0.35% pet. proved to be safe, as far as active sensitization is concerned. To determine whether PPD 0.3% pet. reliably detects PPD sensitization. Patch testing with PPD 0.3% pet. and 1% pet. synchronously was performed in consecutive patients in a multicentre study within the Information Network of Departments of Dermatology. Altogether, 2042 patients were patch tested. PPD 1% pet. yielded 6.0% positive reactions (n = 123), and PPD 0.3% pet. yielded 4.7% (n = 95). The synchronous reproducibility of PPD reactions was similar as known from parallel patch tests with identical PPD concentrations. The diagnostic properties of PPD 0.3% pet. expressed as reaction index and positivity ratio were good. Of the 123 patients reacting to PPD 1% pet., 32 (26%) had no positive reaction to PPD 0.3% pet. In 22 of these 32 patients (69%), no clinical relevance could be found. As patch testing with PPD 0.3% pet. is reliable according to our results, we recommend replacing PPD 1% pet. in the baseline series with PPD 0.3% pet. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. Comparison of Chemical Sensitivity of Fresh and Long-Stored Heat Resistant Neosartorya fischeri Environmental Isolates Using BIOLOG Phenotype MicroArray System.

    Directory of Open Access Journals (Sweden)

    Jacek Panek

    Full Text Available Spoilage of heat processed food and beverage by heat resistant fungi (HRF is a major problem for food industry in many countries. Neosartorya fischeri is the leading source of spoilage in thermally processed products. Its resistance to heat processing and toxigenicity makes studies about Neosartorya fischeri metabolism and chemical sensitivity essential. In this study chemical sensitivity of two environmental Neosartorya fischeri isolates were compared. One was isolated from canned apples in 1923 (DSM3700, the other from thermal processed strawberry product in 2012 (KC179765, used as long-stored and fresh isolate, respectively. The study was conducted using Biolog Phenotype MicroArray platforms of chemical sensitivity panel and traditional hole-plate method. The study allowed for obtaining data about Neosartorya fischeri growth inhibitors. The fresh isolate appeared to be much more resistant to chemical agents than the long-stored isolate. Based on phenotype microarray assay nitrogen compounds, toxic cations and membrane function compounds were the most effective in growth inhibition of N. fischeri isolates. According to the study zaragozic acid A, thallium(I acetate and sodium selenate were potent and promising N. fischeri oriented fungicides which was confirmed by both chemical sensitivity microplates panel and traditional hole-plate methods.

  17. Lettuce contact allergy.

    Science.gov (United States)

    Paulsen, Evy; Andersen, Klaus E

    2016-02-01

    Lettuce (Lactuca sativa L.) and its varieties are important vegetable crops worldwide. They are also well-known, rarely reported, causes of contact allergy. As lettuce allergens and extracts are not commercially available, the allergy may be underdiagnosed. The aims of this article are to present new data on lettuce contact allergy and review the literature. Lettuce is weakly allergenic, and occupational cases are mainly reported. Using aimed patch testing in Compositae-allergic patients, two recent Danish studies showed prevalence rates of positive lettuce reactions of 11% and 22%. The majority of cases are non-occupational, and may partly be caused by cross-reactivity. The sesquiterpene lactone mix seems to be a poor screening agent for lettuce contact allergy, as the prevalence of positive reactions is significantly higher in non-occupationally sensitized patients. Because of the easy degradability of lettuce allergens, it is recommended to patch test with freshly cut lettuce stem and supplement this with Compositae mix. As contact urticaria and protein contact dermatitis may present as dermatitis, it is important to perform prick-to-prick tests, and possibly scratch patch tests as well. Any person who is occupationally exposed to lettuce for longer periods, especially atopics, amateur gardeners, and persons keeping lettuce-eating pets, is potentially at risk of developing lettuce contact allergy. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Tc1-mediated contact sensitivity reaction, its mechanism and regulation

    Directory of Open Access Journals (Sweden)

    Magdalena Zemelka-Wiącek

    2014-07-01

    Full Text Available The contact hypersensitivity reaction (CHS to haptens is a classic example of cell-mediated immune response. In the effector phase, two stages can be distinguished: an early component, that appears only 2 hours after subsequent contact with the hapten, and the late component that develops approximately 24 hours later which is mediated by TCRαβ+ cells. The effector lymphocytes may be CD4+ T helper 1 (Th1 cells or CD8+ T cytotoxic 1 (Tc1 cells, which depends on the employed hapten and/or mice strain. NKT lymphocytes play the crucial role in the CHS initiation, by supporting B1 cells in the antigen-specific IgM antibodies production. The development of an early component is essential for the recruitment of T effector (Teff cells to the side of hapten deposition and for the complete expansion of inflammatory reaction. The CHS reaction is under T regulatory (Treg cells control, both in the induction phase as well as in the effector phase. A new view of a negative regulation of the Tc1 mediated CHS response is based on the suppression induced by epicutaneous (EC application of protein antigen. The DNP-BSA skin application, on a gauze patch, leads to a state of immunosuppression. This maneuver results in rising the population of Treg cells with TCRαβ+CD4+CD25+Foxp3+ phenotype. The mechanism of suppression requires direct contact between Treg cells and Teff cells and the participation of CTLA-4 molecule is also necessary. The described method of evoking immune tolerance via EC immunization may contribute to elaborate a new method of allergic contact dermatitis therapy. This is because of its effectiveness, ease of induction and non-invasive protein antigen application.

  19. Repeated exposures to cobalt or chromate on the hands of patients with hand eczema and contact allergy to that metal

    DEFF Research Database (Denmark)

    Nielsen, N H; Kristiansen, J; Borg, L

    2000-01-01

    The present study aimed at evaluating the effects of daily repeated exposures to low cobalt or chromate concentrations on the hands of patients with hand eczema and cobalt or chromate allergy. For 2 weeks, the patients immersed a finger for 10 min daily into the appropriate metal salt solution in...... of providing evidence-based medicine in the area of allergic contact dermatitis in the future.......-sensitive patients. During the exposure period, accumulation of cobalt or chromate in the nail was demonstrated. Standardization of chemical methods of quantification of skin exposure to allergens, combined with experimental exposure studies in patients with specific contact allergy, will increase the possibility...

  20. Elevated-temperature (6000F), manual contact ultrasonic examination

    International Nuclear Information System (INIS)

    Donnelly, C.W.

    1981-01-01

    Manual contact ultrasonic examination at temperatures above 250 0 F has not been successful in providing meaningful results. Sensitivity of standard transducers degrades rapidly at 250 0 F and above. It has been demonstrated that by using standard transducers and commercially available wedges and couplants in combination with a couplant/cooler system, manual contact ultrasonic examination can be performed at 600 0 F for an essentially 100% duty cycle in conformance to the sensitivity requirement of the ASME B and PV Code

  1. Effect of contact angle and contact angle hysteresis on the floatability of spheres at the air-water interface.

    Science.gov (United States)

    Feng, Dong-Xia; Nguyen, Anh V

    2017-10-01

    The floatability of solid particles on the water surface governs many natural phenomena and industrial processes including film flotation and froth flotation separation of coal and valuable minerals. For many years, the contact angle (CA) has been postulated as the key factor in determining the particle floatability. Indeed, the maximum force (tenacity) supporting the flotation of fine spheres was conjectured to occur when the apical angle of the contact circle is equal to the contact angle. In this paper, the model predictions are reviewed and compared with experimental results. It is shown that CA can be affected by many physical and chemical factors such as surface roughness and chemical heterogeneity and can have a range of values known as the CA hysteresis. This multiple-valued CA invalidates the available theories on the floatability of spheres. Even the intuitive replacement of CA by the advancing (maximum) CA in the classical theories can be wrong. A few new examples are also reviewed and analyzed to demonstrate the significance of CA variation in controlling the particle floatability. They include the pinning of the contact line at the sharp edge, known as the Gibbs inequality condition, and the nearby interaction among floating particles, known as lateral inter-particle interaction. It is concluded that our quantitative understanding of the floatability of real particles being irregular and heterogeneous both morphologically and chemically is still far from being satisfactory. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Micro-light-emitting diodes with III–nitride tunnel junction contacts grown by metalorganic chemical vapor deposition

    KAUST Repository

    Hwang, David

    2017-12-13

    Micro-light-emitting diodes (µLEDs) with tunnel junction (TJ) contacts were grown entirely by metalorganic chemical vapor deposition. A LED structure was grown, treated with UV ozone and hydrofluoric acid, and reloaded into the reactor for TJ regrowth. The silicon doping level of the n++-GaN TJ was varied to examine its effect on voltage. µLEDs from 2.5 × 10−5 to 0.01 mm2 in area were processed, and the voltage penalty of the TJ for the smallest µLED at 20 A/cm2 was 0.60 V relative to that for a standard LED with indium tin oxide. The peak external quantum efficiency of the TJ LED was 34%.

  3. Micro-light-emitting diodes with III–nitride tunnel junction contacts grown by metalorganic chemical vapor deposition

    KAUST Repository

    Hwang, David; Mughal, Asad J.; Wong, Matthew S.; Alhassan, Abdullah I.; Nakamura, Shuji; DenBaars, Steven P.

    2017-01-01

    Micro-light-emitting diodes (µLEDs) with tunnel junction (TJ) contacts were grown entirely by metalorganic chemical vapor deposition. A LED structure was grown, treated with UV ozone and hydrofluoric acid, and reloaded into the reactor for TJ regrowth. The silicon doping level of the n++-GaN TJ was varied to examine its effect on voltage. µLEDs from 2.5 × 10−5 to 0.01 mm2 in area were processed, and the voltage penalty of the TJ for the smallest µLED at 20 A/cm2 was 0.60 V relative to that for a standard LED with indium tin oxide. The peak external quantum efficiency of the TJ LED was 34%.

  4. Surface charging, discharging and chemical modification at a sliding contact

    DEFF Research Database (Denmark)

    Singh, Shailendra Vikram; Kusano, Yukihiro; Morgen, Per

    2012-01-01

    Electrostatic charging, discharging, and consequent surface modification induced by sliding dissimilar surfaces have been studied. The surface-charge related phenomena were monitored by using a home-built capacitive, non-contact electrical probe, and the surface chemistry was studied by X...... are also able to comment on the behavior and the charge decay time in the ambient air-like condition, once the sliding contact is discontinued. XPS analysis showed a marginal deoxidation effect on the polyester disks due to the charging and discharging of the surfaces. Moreover, these XPS results clearly...

  5. QSAR Study of Skin Sensitization Using Local Lymph Node Assay Data

    Directory of Open Access Journals (Sweden)

    Eugene Demchuk

    2004-01-01

    Full Text Available Abstract: Allergic Contact Dermatitis (ACD is a common work-related skin disease that often develops as a result of repetitive skin exposures to a sensitizing chemical agent. A variety of experimental tests have been suggested to assess the skin sensitization potential. We applied a method of Quantitative Structure-Activity Relationship (QSAR to relate measured and calculated physical-chemical properties of chemical compounds to their sensitization potential. Using statistical methods, each of these properties, called molecular descriptors, was tested for its propensity to predict the sensitization potential. A few of the most informative descriptors were subsequently selected to build a model of skin sensitization. In this work sensitization data for the murine Local Lymph Node Assay (LLNA were used. In principle, LLNA provides a standardized continuous scale suitable for quantitative assessment of skin sensitization. However, at present many LLNA results are still reported on a dichotomous scale, which is consistent with the scale of guinea pig tests, which were widely used in past years. Therefore, in this study only a dichotomous version of the LLNA data was used. To the statistical end, we relied on the logistic regression approach. This approach provides a statistical tool for investigating and predicting skin sensitization that is expressed only in categorical terms of activity and nonactivity. Based on the data of compounds used in this study, our results suggest a QSAR model of ACD that is based on the following descriptors: nDB (number of double bonds, C-003 (number of CHR3 molecular subfragments, GATS6M (autocorrelation coefficient and HATS6m (GETAWAY descriptor, although the relevance of the identified descriptors to the continuous ACD QSAR has yet to be shown. The proposed QSAR model gives a percentage of positively predicted responses of 83% on the training set of compounds, and in cross validation it correctly identifies 79% of

  6. Follicular contact dermatitis revisited: A review emphasizing neomycin-associated follicular contact dermatitis

    Science.gov (United States)

    Cohen, Philip R

    2014-01-01

    Follicular contact dermatitis clinically presents as individual papules that include a central hair follicle. Pathologic features involve the follicle and the surrounding dermis: spongiosis and vesicle formation of the follicular epithelium associated with perifollicular and perivascular lymphocytic inflammation. Using the PubMed database, an extensive literature search was performed on follicular contact dermatitis and neomycin. Relevant papers were reviewed and the clinical and pathologic features, the associated chemicals (including a more detailed description of neomycin), the hypothesized pathogenesis, and the management of follicular contact dermatitis were described. Several agents-either as allergens or irritants-have been reported to elicit follicular contact dermatitis. Several hypotheses have been suggested for the selective involvement of the follicles in follicular contact dermatitis: patient allergenicity, characteristics of the agent, vehicle containing the agent, application of the agent, and external factors. The differential diagnosis of follicular contact dermatitis includes not only recurrent infundibulofolliculitis, but also drug eruption, mite infestation, viral infection, and dermatoses that affect hair follicles. The primary therapeutic intervention for follicular contact dermatitis is withdrawal of the causative agent; treatment with a topical corticosteroid preparation may also promote resolution of the dermatitis. In conclusion, follicular contact dermatitis may be secondary to allergens or irritants; topical antibiotics, including neomycin, may cause this condition. Several factors may account for the selective involvement of the hair follicle in this condition. Treatment of the dermatitis requires withdrawal of the associated topical agent; in addition, topical corticosteroids may be helpful to promote resolution of lesions. PMID:25516854

  7. Gas-liquid contacting in mixing vessels

    International Nuclear Information System (INIS)

    Mann, R.

    1983-01-01

    This report by Dr. R. Mann of UMIST presents a critical survey of literature on the contacting of gases with liquids in stirred vessels. Research undertaken in the last fifteen years in analysed, and promising areas for future research are identified. The report deals with physical contacting, mass transfer between the gas and liquid phases and the utilisation of the stirred vessel as a gas-liquid reactor. Three sections are given on gas-liquid contacting: physical aspects; interphase mass transfer; and chemical reactions. It also discusses recent new approaches and includes a summary of conclusions, nomenclature and references

  8. Supersensitive, Fast-Response Nanowire Sensors by Using Schottky Contacts

    KAUST Repository

    Hu, Youfan

    2010-05-31

    A Schottky barrier can be formed at the interface between a metal electrode and a semiconductor. The current passing through the metal-semiconductor contact is mainly controlled by the barrier height and barrier width. In conventional nanodevices, Schottky contacts are usually avoided in order to enhance the contribution made by the nanowires or nanotubes to the detected signal. We present a key idea of using the Schottky contact to achieve supersensitive and fast response nanowire-based nanosensors. We have illustrated this idea on several platforms: UV sensors, biosensors, and gas sensors. The gigantic enhancement in sensitivity of up to 5 orders of magnitude shows that an effective usage of the Schottky contact can be very beneficial to the sensitivity of nanosensors. © 2010 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Improving the photovoltaic parameters in Quantum dot sensitized solar cells through employment of chemically deposited compact titania blocking layer

    Energy Technology Data Exchange (ETDEWEB)

    Rajendra Prasad, M.B., E-mail: rajendraprasadmb75@gmail.com [Advanced Physics Laboratory, Department of Physics, SavitibaiPhule Pune University, Pune, 411007 (India); National Defence Academy, Khadakwasla, Pune, 411023 (India); Kadam, Vishal [Advanced Physics Laboratory, Department of Physics, SavitibaiPhule Pune University, Pune, 411007 (India); Joo, Oh-Shim [Korea Institute of Science and Technology, PO Box No. 131, Chongryang, Seoul, 130-650 (Korea, Republic of); Pathan, Habib M. [Advanced Physics Laboratory, Department of Physics, SavitibaiPhule Pune University, Pune, 411007 (India)

    2017-06-15

    Incorporation of compact blocking layer at the Transparent Conducting Oxide (TCO)/Electrolyte interface is an effective method to improve the device performance in QDSSC through mitigation of electron recombinations at this interface. This paper reports the most facile and cost effective method of depositing a rutile titania Compact Layer (CL) over Fluorine doped Tin Oxide (FTO) substrate and its application in titania based CdS QD sensitized solar cells. The deposited compact layers are characterized to study their structural, optical, morphological and electrochemical properties using X-Ray Diffractometry, UV–Visible spectroscopy, Scanning electron microscopy, Cyclic Voltammetry and Contact Angle measurements. Sandwich solar cells are fabricated using these CL based electrodes and characterized using Electrochemical Impedance Spectroscopy, Open Circuit Voltage Decay and J-V characteristics. The CL incorporated CdS QDSSC showed more than 100% increase in the photoconversion efficiency (1.68%) as compared to its bare FTO counterpart (0.73%) proving the efficacy of employed strategy. - Highlights: • Deposited titania compact layer by a facile room temperature chemical bath method. • Employed this to mitigate back electron transfer at TCO/Electrolyte interface. • Compact layer incorporation has improved the solar cell performance by 130%.

  10. Investigation of the effect of water exposed to nonequilibrium contact plasma onto saccharomyces cerevisiae yeast

    Directory of Open Access Journals (Sweden)

    S. Mykolenko

    2015-05-01

    Full Text Available Introduction. Additional treatment of water by nonequilibrium contact plasma allows improving consumer characteristics of bakery goods considerably. Determination of the effect of plasma-chemically activated water on morphological, cultural and physiological properties of Saccharomyces cerevisiae yeast is important from the technological point of view. Materials and Methods. Experimental investigations were carried out in the conditions of bacteriological laboratory by seeding the culture of yeasts of ТМ “Lvivski” and “Kryvorizki” on Sabouraud dense liquid nutrient media. The quantity of viable cells of microorganisms was determined by the method of Gould sector seeds. Morphology of the yeast was investigated by phase-contrast microscopy. Biotechnological properties of yeasts were determined on Giss media. Results. The paper establishes the effect of water exposed to nonequilibrium contact plasma on the sensitivity of Saccharomyces cerevisiae and shows absence of suppressive action of treated water with regard to cultural properties of microorganisms. The experiments prove that with the use of plasma-chemically activated water morphological characteristics and biochemical properties of bakery yeasts produced by Lviv and Kryvyi Rig yeast plants are preserved. Culturing of Saccharomyces cerevisiae yeast on the nutrient media prepared with the use of water exposed to nonequilibrium contact plasm resulted in 6,5–15 times’ increase in quantity of viable microorganisms compared with the control on the mains drinking water. Conclusions. Physiological properties of Saccharomyces cerevisiae yeast improved owing to use water exposed to nonequilibrium contact plasma. Results of investigations are recommended for using in yeast production and bread making.

  11. Cellular dynamics in the draining lymph nodes during sensitization and elicitation phases of contact hypersensitivity

    DEFF Research Database (Denmark)

    Larsen, Jeppe Madura; Geisler, Carsten; Nielsen, Martin Weiss

    2007-01-01

    BACKGROUND: The different role of various immunological effector cells in contact hypersensitivity (CHS) is receiving increased attention. During the past decade, the involvement of different cell types in CHS has been investigated by the use of antibody-induced depletion of specific subtypes...... of immunological cells and by studying knockout mice lacking one or more of these immunological cell populations. OBJECTIVES: To develop a method for studying the collective cellular dynamics of immune cells in the draining lymph nodes during CHS in intact animals. PATIENTS/METHODS: Mice were sensitized and....../or challenged with 2,4-dinitrofluorobenzene or oxazolone. Using multi-parameter flow cytometry we determined the proliferation, activation state, and absolute number of helper T cells, cytotoxic T cells, B cells, and natural killer cells in the draining lymph nodes. RESULTS: The presented method can be applied...

  12. Risk factors associated with sensitization to hydroxyisohexyl 3-cyclohexene carboxaldehyde.

    Science.gov (United States)

    Uter, Wolfgang; Geier, Johannes; Schnuch, Axel; Gefeller, Olaf

    2013-08-01

    Hydroxyisohexyl 3-cyclohexene carboxaldehyde (HICC) is a synthetic fragrance chemical and an important contact allergen, at least in Europe. Despite this importance, little is known about risk factors associated with this allergen. To examine factors from the history and clinical presentation of patch tested patients associated with HICC sensitization. Contact allergy surveillance data of 95 637 patients collected by the Information Network of Departments of Dermatology (IVDK, www.ivkd.org) in 2002-2011 were analysed. Point and interval estimates of the relative risk were derived from multifactorial logistic regression modelling. The overall prevalence of HICC sensitization was 2.24%. The strongest risk factors were polysensitization and dermatitis of the axillae, followed by dermatitis at other sites. No consistent and significant time trend was observed in this analysis. As compared with the youngest patients, the odds of HICC sensitization increased approximately three-fold in the 52-67-year age group, and strongly declined with further increasing age. The risk pattern with regard to age and affected anatomical site differed from that observed with other fragrance screening allergens. Cosmetic exposure, as broadly defined here, was a stronger and more prevalent individual risk factor than occupational exposure. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Sensitivity of juvenile striped bass to chemicals used in aquaculture

    Science.gov (United States)

    Bills, Terry D.; Marking, Leif L.; Howe, George E.

    1993-01-01

    Efforts to restore anadromous striped bass (Morone saxatilis) populations by the U.S. Fish and Wildlife Service and other agencies over the past 20 years have concentrated on hatchery culture to supplement dwindling natural reproduction. Adult fish captured for artificial spawning are stressed by handling and crowding in rearing ponds and are often exposed to therapeutants, anesthetics, disinfectants, and herbicides used in fish culture. We determined the toxicity of 17 fishery chemicals (chloramine-T, erythromycin, formalin, Hyamine 3500, Roccal, malachite green, sulfamerazine, benzocaine, etomidate, Finquel (MS-222) , metomidate, quinaldine sulfate, chlorine, potassium permanganate, Aquazine, copper sulfate, and Rodeo) to striped bass fry (average weight = 1 g) in reconstituted water (total hardness 40 mg/L) at 12 degree C. The 96-h LC50's (concentration calculated to produce 50% mortality in a population) ranged from 0.129 mg/L for malachite green to 340 mg/L for erythromycin. We also determined the effects of selected levels of water temperature, hardness, and pH on the toxicity of chloramine-T, formalin, malachite green, and Roccal. There were no differences in toxicity for any of the chemicals at any water quality variable tested except for chloramine-T, which was about 25 times more toxic in soft, acid water than in soft, alkaline water. Our data show that the striped bass is as sensitive to fishery chemicals as rainbow trout (Oncorhynchus mykiss), but is generally less resistant than bluegill (Lepomis macrochirus) and channel catfish (Ictalurus punctatus).

  14. Contact eczema and tumors caused by chromium, nickel and their compounds. An evaluation of occupational diseases approved from 1978 until 1984

    Energy Technology Data Exchange (ETDEWEB)

    Wardenbach, P.; Henter, A.; Kollmeier, H.

    1989-07-01

    The majority of the approved occupational diseases caused by chromium, nickel and their compounds are contact eczema. Only in chemical workers contact eczema and tumors of the respiratory tract are recognized with a comparable frequency. Within the textile and leather branche no contact exzema were caused by chromium. It is conceivable that technology changes and/or substitution of sensitizing chromium compounds in tanning entailed a considerable decrease of this disease. Quantitative data of exposures, which caused the recently observed tumors of the respiratory tract, are not available. From recently published workplace measurements it can be deduced that at the corresponding workplaces even nowadays the heaviest exposures exist. As the formerly established MAK values are nearly identical with the current TRK values a reevaluation of the latter should be performed. (orig.).

  15. Occupational irritant contact dermatitis diagnosed by analysis of contact irritants and allergens in the work environment

    DEFF Research Database (Denmark)

    Friis, Ulrik F; Menné, Torkil; Schwensen, Jakob F

    2014-01-01

    BACKGROUND: Irritant contact dermatitis (ICD) is a common diagnosis in patients with occupational contact dermatitis (OCD). Studies are lacking on the usefulness of material safety data sheets (MSDSs) in making the diagnosis of ICD. OBJECTIVE: To characterize irritant exposures leading...... to the diagnosis of occupational ICD (OICD), and to evaluate the occurrence of concomitant exposures to contact allergens. METHODS: We included 316 patients with suspected occupational hand dermatitis, referred to the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte, Denmark during......), mechanical traumas (n = 19), and oils (n = 15). Exposure to specific irritant chemicals was found in 9 patients, and was identified from MSDSs/ingredients labelling in 8 of these patients. Review of MSDSs and ingredients labelling showed that 41 patients were exposed to 41 moderate to potent contact...

  16. Inflammatory Mediator Profiling of n-butanol Exposed Upper Airways in Individuals with Multiple Chemical Sensitivity

    DEFF Research Database (Denmark)

    Dantoft, Thomas Meinertz; Skovbjerg, Sine; Andersson, Linus

    2015-01-01

    Multiple Chemical Sensitivity (MCS) is a chronic condition characterized by reports of recurrent symptoms in response to low level exposure to various chemical substances. Recent findings suggests that dysregulation of the immune system may play a role in MCS pathophysiology. The aim of this study...... inflammatory mediator profiles (P>0.05) at baseline. Likewise, direct comparison of mediator levels in the MCS group and controls after n-butanol exposure revealed no significant group differences. We demonstrate no abnormal upper airway inflammatory mediator levels in MCS subjects before or after a symptom...

  17. Correlation between chemical, crystallographic and spectroscopic parameters in graphite thermometry applied to a contact aureole of La Soledad monzogranite (Venezuelan Andes

    Directory of Open Access Journals (Sweden)

    K. Reategui

    2017-11-01

    Full Text Available Graphite samples from a metamorphic contact aureole between phyllites of the Cerro Azul Association (Palaeozoic and La Soledad Monzogranite, in the Venezuelan Andes, were studied by chemical (% inorganic carbon and isotopic distribution, crystallographic (DRX and spectroscopic (Raman techniques in order to assess changes in the graphite in the vicinity of the contact, the correlation between the different parameters, and the determination of the higher temperature reached by the host rock during igneous intrusion. The δ13C reached less negative values near the monzogranite, caused by devolatilization; the graphite present just in contact with the pluton experienced retrograde recrystallization, which causes a shift towards more negative values. The calculated degree of graphitization intervals (GD = 53–80 corresponds to a well-structured mineral with ordered packaging. The peak metamorphic temperature at the contact was calculated from crystallographic (XRD and spectroscopic (Raman parameters with great agreement in both techniques, registering the 528 ± 16 and 526 ± 20 ºC respectively. The metapelitic rocks reached the Cordierite Zone (cordierite + biotite + muscovite in the contact aureole where the graphite is well ordered and in hexagonal microtexture. Factors such as fluid activity and the subsequent retrograde recrystallization have an effect on isotopic redistributions after the intrusive event, as well as on the crystallinity change rate with the temperature, avoiding a clear correlation between the isotopic variations of 13C in graphite and the temperature.

  18. PREFACE: Non-contact AFM Non-contact AFM

    Science.gov (United States)

    Giessibl, Franz J.; Morita, Seizo

    2012-02-01

    This special issue is focussed on high resolution non-contact atomic force microscopy (AFM). Non-contact atomic force microscopy was established approximately 15 years ago as a tool to image conducting and insulating surfaces with atomic resolution. Since 1998, an annual international conference has taken place, and although the proceedings of these conferences are a useful source of information, several key developments warrant devoting a special issue to this subject. In the theoretic field, the possibility of supplementing established techniques such as scanning tunneling microscopy (STM) and Kelvin probe microscopy with atomically resolved force micrsoscopy poses many challenges in the calculation of contrast and contrast reversal. The surface science of insulators, self-assembled monolayers and adsorbates on insulators is a fruitful field for the application of non-contact AFM: several articles in this issue are devoted to these subjects. Atomic imaging and manipulation have been pioneered using STM, but because AFM allows the measurement of forces, AFM has had a profound impact in this field as well. Three-dimensional force spectroscopy has allowed many important insights into surface science. In this issue a combined 3D tunneling and force microscopy is introduced. Non-contact AFM typically uses frequency modulation to measure force gradients and was initially used mainly in a vacuum. As can be seen in this issue, frequency modulation is now also used in ambient conditions, allowing better spatial and force resolution. We thank all of the contributors for their time and efforts in making this special issue possible. We are also very grateful to the staff of IOP Publishing for handling the administrative aspects and for steering the refereeing process. Non-contact AFM contents Relation between the chemical force and the tunnelling current in atomic point contacts: a simple model Pavel Jelínek, Martin Ondrácek and Fernando Flores Theoretical simulation of

  19. Occupations at risk of developing contact allergy to isothiazolinones in Danish contact dermatitis patients: results from a Danish multicentre study (2009-2012).

    Science.gov (United States)

    Schwensen, Jakob F; Menné, Torkil; Andersen, Klaus E; Sommerlund, Mette; Johansen, Jeanne D

    2014-11-01

    In recent years, the prevalence of contact allergy to isothiazolinones has reached epidemic levels. Few studies have presented data on occupations at risk of developing contact allergy to isothiazolinones. To present demographics and examine risk factors for sensitization to methylisothiazolinone (MI), methylchloroisothiazolinone (MCI) in combination with MI and benzisothiazolinone (BIT) in Danish dermatitis patients. A retrospective epidemiological analysis of data from three Danish hospitals departments was conducted. All patients consecutively patch tested with MI, MCI/MI and BIT between 2009 and 2013 were included. MI contact allergy showed a significantly increased trend in prevalence from 1.8% in 2009 to 4.2% in 2012 (p dermatitis mainly drove the increase in 2012. Adjusted logistic regression analysis showed that MI sensitization was significantly associated with occupational exposures, hand and facial dermatitis, age > 40 years, and the occupational groups of tile setters/terrazzo workers, machine operators, and painters. MCI/MI contact allergy was significantly associated with the following high-risk occupations: painting, welding (blacksmiths), machine operating, and cosmetology. The occupational group of painting was frequent in the group of patients with BIT contact allergy. Several high-risk occupations for sensitization to isothiazolinones exist. Regulation on the allowed concentration of isothiazolinones, and especially MI, in both consumer products and industrial products is needed. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. European Surveillance System on Contact Allergies (ESSCA)

    DEFF Research Database (Denmark)

    Uter, W; Amario-Hita, J C; Balato, A

    2017-01-01

    BACKGROUND: Contact allergy is a common condition and can severely interfere with daily life or professional activities. Due to changes in exposures, such as introduction of new substances, new products or formulations and regulatory intervention, the spectrum of contact sensitization changes....... OBJECTIVE: To evaluate the current spectrum of contact allergy to allergens present in the European baseline series (EBS) across Europe. METHODS: Retrospective analysis of data collected by the European Surveillance System on Contact Allergies (ESSCA, www.essca-dc.org) in consecutively patch-tested patients......, 2013/14, in 46 departments in 12 European countries. RESULTS: Altogether, 31 689 patients were included in the analysis. Compared to a similar analysis in 2004, the prevalence of contact allergy to methylisothiazolinone went up to around 20% in several departments. In comparison, contact allergy...

  1. Elastic contact mechanics: percolation of the contact area and fluid squeeze-out.

    Science.gov (United States)

    Persson, B N J; Prodanov, N; Krick, B A; Rodriguez, N; Mulakaluri, N; Sawyer, W G; Mangiagalli, P

    2012-01-01

    The dynamics of fluid flow at the interface between elastic solids with rough surfaces depends sensitively on the area of real contact, in particular close to the percolation threshold, where an irregular network of narrow flow channels prevails. In this paper, numerical simulation and experimental results for the contact between elastic solids with isotropic and anisotropic surface roughness are compared with the predictions of a theory based on the Persson contact mechanics theory and the Bruggeman effective medium theory. The theory predictions are in good agreement with the experimental and numerical simulation results and the (small) deviation can be understood as a finite-size effect. The fluid squeeze-out at the interface between elastic solids with randomly rough surfaces is studied. We present results for such high contact pressures that the area of real contact percolates, giving rise to sealed-off domains with pressurized fluid at the interface. The theoretical predictions are compared to experimental data for a simple model system (a rubber block squeezed against a flat glass plate), and for prefilled syringes, where the rubber plunger stopper is lubricated by a high-viscosity silicon oil to ensure functionality of the delivery device. For the latter system we compare the breakloose (or static) friction, as a function of the time of stationary contact, to the theory prediction.

  2. Bone char quality and defluoridation capacity in contact precipitation

    DEFF Research Database (Denmark)

    Albertus, J.; Bregnhøj, Henrik; Kongpun, M.

    2002-01-01

    are added as in the contact precipitation process. The results show that the columns are able to remove up to 700 bedvolumes, before the concentration of fluoride in the effluent water breaks through, above 1.5 mg/L. Operational removal capacities observed are 7 and 9 mg/L, depending on contact time...... and the dosage of chemicals. It is discussed that longer contact time and higher dosage of calcium and phosphate may result in longer operation periods in the contact precipitation columns....

  3. Clinical performance of Rose K2 soft contact lens for keratoconus

    Directory of Open Access Journals (Sweden)

    Ihsan Yilmaz

    2017-08-01

    Full Text Available AIM: To evaluate the comfort and visual performance of Rose K2 soft contact lenses in patients with keratoconus.METHODS: Fifty eyes of 50 participants were included in this cross-sectional study. Each participant received a full ophthalmologic examination involving refraction, uncorrected visual acuity(UCVA, best spectacle corrected visual acuity(BCVA, slit-lamp biomicroscopy-fundoscopy, break-up time(BUT, corneal topography, and contrast sensitivity. After contact lens was fitted best contact lens corrected visual acuity(BCLCVA, contrast sensitivity, and comfort rating via visual analogue scales(VASwere performed.RESULTS: The mean age was 26.2±6.0(range: 16 to 39y. The mean logMAR UCVA, BCVA, and BCLCVA with Rose K2 soft(in orderwere 0.61±0.37(range: 0.15-1.3, 0.42±0.32(range: 0-1.3, and 0.18±0.20(range: 0-1.3. There were significant increases in visual acuities with contact lenses(P P CONCLUSION: Rose K2 soft contact lens can improve visual acuity, contrast sensitivity with comfort in patients with keratoconus.

  4. Process development for waveguide chemical sensors with integrated polymeric sensitive layers

    Science.gov (United States)

    Amberkar, Raghu; Gao, Zhan; Park, Jongwon; Henthorn, David B.; Kim, Chang-Soo

    2008-02-01

    Due to the proper optical property and flexibility in the process development, an epoxy-based, high-aspect ratio photoresist SU-8 is now attracting attention in optical sensing applications. Manipulation of the surface properties of SU-8 waveguides is critical to attach functional films such as chemically-sensitive layers. We describe a new integration process to immobilize fluorescence molecules on SU-8 waveguide surface for application to intensity-based optical chemical sensors. We use two polymers for this application. Spin-on, hydrophobic, photopatternable silicone is a convenient material to contain fluorophore molecules and to pattern a photolithographically defined thin layer on the surface of SU-8. We use fumed silica powders as an additive to uniformly disperse the fluorophores in the silicone precursor. In general, additional processes are not critically required to promote the adhesion between the SU-8 and silicone. The other material is polyethylene glycol diacrylate (PEGDA). Recently we demonstrated a novel photografting method to modify the surface of SU-8 using a surface bound initiator to control its wettability. The activated surface is then coated with a monomer precursor solution. Polymerization follows when the sample is exposed to UV irradiation, resulting in a grafted PEGDA layer incorporating fluorophores within the hydrogel matrix. Since this method is based the UV-based photografting reaction, it is possible to grow off photolithographically defined hydrogel patterns on the waveguide structures. The resulting films will be viable integrated components in optical bioanalytical sensors. This is a promising technique for integrated chemical sensors both for planar type waveguide and vertical type waveguide chemical sensors.

  5. Advantages of Chemical Exchange-Sensitive Spin-Lock (CESL) Over Saturation Transfer (CEST) for Hydroxyl- and Amine-Water Proton Exchange Studies

    Science.gov (United States)

    Jin, Tao; Kim, Seong-Gi

    2014-01-01

    The chemical exchange (CE) rate of endogenous hydroxyl and amine protons with water is often comparable to the difference in their chemical shifts. These intermediate exchange (IMEX) processes have been imaged by the CE saturation transfer (CEST) approach with low-power and long-duration irradiation. However, its sensitivity is not optimal, and more importantly, the signal is contaminated by slow magnetization transfer processes. Here, the property of CEST signals is compared to a CE-sensitive spin-locking (CESL) technique irradiating at the labile proton frequency. Firstly, using a higher power and shorter irradiation in CE-MRI yields i) increasing selectivity to faster chemical exchange rates by higher sensitivity to faster exchanges and less sensitivity to slower CE and magnetization transfer processes, and ii) decreasing in vivo asymmetric magnetization transfer contrast measured at ±15 ppm. The sensitivity gain of CESL over CEST is higher for a higher-power and shorter irradiation. Unlike CESL, CEST signals oscillate at a very high power and short irradiation. Secondly, time-dependent CEST and CESL signals are well modeled by analytical solutions of CE-MRI with asymmetric population approximation (CEAPA), which can be used for quantitative CE-MRI, and validated by simulations of Bloch-McConnell equations and phantom experiments. Lastly, in vivo amine-water proton exchange contrast measured at 2.5 ppm with ω1 of 500 Hz is 18% higher in sensitivity for CESL than CEST at 9.4 T. Overall, CESL provides better exchange rate selectivity and sensitivity than CEST; therefore, CESL is more suitable for CE-MRI of IMEX protons. PMID:25199631

  6. Effect of chemical heterogeneity of biodegradable polymers on surface energy: A static contact angle analysis of polyester model films

    Energy Technology Data Exchange (ETDEWEB)

    Belibel, R.; Avramoglou, T. [INSERM U1148, Laboratory for Vascular Translational Science (LVTS), Institut Galilée, Université Paris 13, Sorbonne Paris Cité, 99 Avenue Jean-Baptiste Clément, Villetaneuse F-93430 (France); Garcia, A. [CNRS UPR 3407, Laboratoire des Sciences des Procédés et des Matériau, Institut Galilée, Université Paris 13, Sorbonne Paris Cité, 99 Avenue Jean-Baptiste Clément, Villetaneuse F-93430 (France); Barbaud, C. [INSERM U1148, Laboratory for Vascular Translational Science (LVTS), Institut Galilée, Université Paris 13, Sorbonne Paris Cité, 99 Avenue Jean-Baptiste Clément, Villetaneuse F-93430 (France); Mora, L., E-mail: Laurence.mora@univ-paris13.fr [INSERM U1148, Laboratory for Vascular Translational Science (LVTS), Institut Galilée, Université Paris 13, Sorbonne Paris Cité, 99 Avenue Jean-Baptiste Clément, Villetaneuse F-93430 (France)

    2016-02-01

    Biodegradable and bioassimilable poly((R,S)-3,3 dimethylmalic acid) (PDMMLA) derivatives were synthesized and characterized in order to develop a new coating for coronary endoprosthesis enabling the reduction of restenosis. The PDMMLA was chemically modified to form different custom groups in its side chain. Three side groups were chosen: the hexyl group for its hydrophobic nature, the carboxylic acid and alcohol groups for their acid and neutral hydrophilic character, respectively. The sessile drop method was applied to characterize the wettability of biodegradable polymer film coatings. Surface energy and components were calculated. The van Oss approach helped reach not only the dispersive and polar acid–base components of surface energy but also acid and basic components. Surface topography was quantified by atomic force microscopy (AFM) and subnanometer average values of roughness (Ra) were obtained for all the analyzed surfaces. Thus, roughness was considered to have a negligible effect on wettability measurements. In contrast, heterogeneous surfaces had to be corrected by the Cassie–Baxter equation for copolymers (10/90, 20/80 and 30/70). The impact of this correction was quantified for all the wettability parameters. Very high relative corrections (%) were found, reaching 100% for energies and 30% for contact angles. - Highlights: • We develop different polymers with various chemical compositions. • Wettability properties were calculated using Cassie corrected contact angles. • Percentage of acid groups in polymers is directly correlated to acid part of SFE. • Cassie corrections are necessary for heterogeneous polymers.

  7. Contact Dermatitis for the Practicing Allergist.

    Science.gov (United States)

    Bernstein, David I

    2015-01-01

    This article provides an overview of important practice recommendations from the recently updated Contact Dermatitis Practice Parameter. This updated parameter provides essential recommendations pertaining to clinical history, physical examination, and patch testing evaluation of patients suspected of allergic contact dermatitis. In addition to providing guidance for performing and interpreting closed patch testing, the updated parameter provides concrete recommendations for assessing metal hypersensitivity in patients receiving prosthetic devices, for evaluating workers with occupational contact dermatitis, and also for addressing allergic contact dermatitis in children. Finally, the document provides practical recommendations useful for educating patients regarding avoidance of exposure to known contact sensitizers in the home and at work. The Contact Dermatitis Parameter is designed as a practical, evidence-based clinical tool to be used by allergists and dermatologists who routinely are called upon to evaluate patients with skin disorders. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  8. Control of peptide nanotube diameter by chemical modifications of an aromatic residue involved in a single close contact

    Science.gov (United States)

    Tarabout, Christophe; Roux, Stéphane; Gobeaux, Frédéric; Fay, Nicolas; Pouget, Emilie; Meriadec, Cristelle; Ligeti, Melinda; Thomas, Daniel; IJsselstijn, Maarten; Besselievre, François; Buisson, David-Alexandre; Verbavatz, Jean-Marc; Petitjean, Michel; Valéry, Céline; Perrin, Lionel; Rousseau, Bernard; Artzner, Franck; Paternostre, Maité; Cintrat, Jean-Christophe

    2011-01-01

    Supramolecular self-assembly is an attractive pathway for bottom-up synthesis of novel nanomaterials. In particular, this approach allows the spontaneous formation of structures of well-defined shapes and monodisperse characteristic sizes. Because nanotechnology mainly relies on size-dependent physical phenomena, the control of monodispersity is required, but the possibility of tuning the size is also essential. For self-assembling systems, shape, size, and monodispersity are mainly settled by the chemical structure of the building block. Attempts to change the size notably by chemical modification usually end up with the loss of self-assembly. Here, we generated a library of 17 peptides forming nanotubes of monodisperse diameter ranging from 10 to 36 nm. A structural model taking into account close contacts explains how a modification of a few Å of a single aromatic residue induces a fourfold increase in nanotube diameter. The application of such a strategy is demonstrated by the formation of silica nanotubes of various diameters. PMID:21518895

  9. Respiratory sensitization and allergy: Current research approaches and needs

    International Nuclear Information System (INIS)

    Boverhof, Darrell R.; Billington, Richard; Gollapudi, B. Bhaskar; Hotchkiss, John A.; Krieger, Shannon M.; Poole, Alan; Wiescinski, Connie M.; Woolhiser, Michael R.

    2008-01-01

    There are currently no accepted regulatory models for assessing the potential of a substance to cause respiratory sensitization and allergy. In contrast, a number of models exist for the assessment of contact sensitization and allergic contact dermatitis (ACD). Research indicates that respiratory sensitizers may be identified through contact sensitization assays such as the local lymph node assay, although only a small subset of the compounds that yield positive results in these assays are actually respiratory sensitizers. Due to the increasing health concerns associated with occupational asthma and the impending directives on the regulation of respiratory sensitizers and allergens, an approach which can identify these compounds and distinguish them from contact sensitizers is required. This report discusses some of the important contrasts between respiratory allergy and ACD, and highlights several prominent in vivo, in vitro and in silico approaches that are being applied or could be further developed to identify compounds capable of causing respiratory allergy. Although a number of animal models have been used for researching respiratory sensitization and allergy, protocols and endpoints for these approaches are often inconsistent, costly and difficult to reproduce, thereby limiting meaningful comparisons of data between laboratories and development of a consensus approach. A number of emerging in vitro and in silico models show promise for use in the characterization of contact sensitization potential and should be further explored for their ability to identify and differentiate contact and respiratory sensitizers. Ultimately, the development of a consistent, accurate and cost-effective model will likely incorporate a number of these approaches and will require effective communication, collaboration and consensus among all stakeholders

  10. Prevalence and interest in the practice of scratch testing for contact urticaria: a survey of the American contact dermatitis society members.

    Science.gov (United States)

    Orb, Quinn; Millsop, Jillian Wong; Harris, KaLynne; Powell, Douglas

    2014-01-01

    Contact urticaria (CU) is the development of a wheal and flare on the skin after topical exposure to a particular chemical or compound. It can be diagnosed through a variety of techniques. Many chemicals that cause a type IV allergy can also cause CU. The incidence of CU to these chemicals is unknown. The aim of this study was to evaluate the opinions of the American Contact Dermatitis Society members regarding CU and scratch testing. We distributed an electronic survey to the American Contact Dermatitis Society members regarding observed prevalence of CU, frequency of scratch testing in clinical practice, and interest in learning about scratch testing in diagnosing CU and other skin contact conditions. We distributed 508 surveys and received 133 responses. Seventeen percent reported that CU was extremely rare, 32% reported that CU was rare, and 38.9% reported that CU was infrequent. Alternatively, 10.7% believed that CU was common, and 1.5% believed that CU was extremely common. A minority, 19.1%, performed scratch testing on patients with suspected CU. Most respondents, 54.6%, were interested in learning about scratch testing. Additional education regarding scratch testing could increase comfort and use of scratch testing in clinical practice. Further studies are needed to evaluate the prevalence of CU in the general population and better guide the use of testing for dermatologic patients.

  11. Effects of gamma irradiation on food contact polyethylene, polypropylene and polystyrene: additives and other chemicals

    International Nuclear Information System (INIS)

    Kawamura, Yoko; Sayama, Kayo; Yamada, Takashi

    2000-01-01

    The effects of gamma irradiation on additives, oligomers, and other chemicals in food contact polyethylene, polypropylene and polystyrene were investigated. Polyethylene and polypropylene products contained several antioxidants, lubricants and plasticizers. After gamma irradiation, the contents of all the antioxidants significantly decreased. Irgafos 168 disappeared the fastest. Lubricants and plasticizers decreased to some extent or not at all. 2,4-Di-tert-butylphenol was detected not only after irradiation but also before irradiation, and 1,3-di-tert-butylbenzene and 2,6-di-tert-butyl-1,4-benzoquinone were detected only after irradiation. They were presumed to be degradation products of the irradiation, though the former should be also a degradation product of the manufacturing process. On the other hand, the polystyrene products contained styrene dimers and trimers and their contents did not change after the gamma irradiation. (author)

  12. Ranking of hair dye substances according to predicted sensitization potency

    DEFF Research Database (Denmark)

    Søsted, H; Basketter, D A; Estrada, E

    2004-01-01

    Allergic contact dermatitis following the use of hair dyes is well known. Many chemicals are used in hair dyes and it is unlikely that all cases of hair dye allergy can be diagnosed by means of patch testing with p-phenylenediamine (PPD). The objectives of this study are to identify all hair dye...... in order to help select a number of chemically diverse hair dye substances that could be used in subsequent clinical work. Various information sources, including the Inventory of Cosmetics Ingredients, new regulations on cosmetics, data on total use and ChemId (the Chemical Search Input website provided...... by the National Library of Medicine), were used in order to identify the names and structures of the hair dyes. A QSAR model, developed with the help of experimental local lymph node assay data and topological sub-structural molecular descriptors (TOPS-MODE), was used in order to predict the likely sensitization...

  13. Occupational contact dermatitis in blue-collar workers

    DEFF Research Database (Denmark)

    Schwensen, Jakob F; Menné, Torkil; Veien, Niels K

    2014-01-01

    BACKGROUND: Blue-collar workers have a high risk of occupational contact dermatitis, but epidemiological studies are scarce. OBJECTIVES: To investigate allergic contact dermatitis in blue-collar workers with dermatitis registered by the Danish Contact Dermatitis Group. METHODS: A retrospective...... analysis of patch test data from 1471 blue-collar workers and 1471 matched controls tested between 2003 and 2012 was performed. A logistic regression was used to test for associations. RESULTS: The blue-collar workers often had occupational hand dermatitis (p dermatitis was less commonly......, and methylchloroisothiazolinone (MCI)/methylisothiazolinone (MI). The following occupations were additionally identified as risk factors for contact sensitization to MCI/MI and MI, epoxy resins, and potassium dichromate, respectively: painting, construction work, and tile setting/terrazzo work. CONCLUSION: Contact allergy...

  14. Sensitivity of chemically and electrochemically etched CR 39 polymers to the neutrons of AmBe source

    International Nuclear Information System (INIS)

    Turek, K.; Spurny, F.; Dajko, G.; Somogyi, G.

    1981-01-01

    Seven samples of polymers by different manufacturers were used in a study of the sensitivity of CR 39 polymers to Am-Be neutrons. In the polymer, proton tracks for a relatively broad energy range can also be recorded. The following characteristics were studied: the sample background for different etching methods, the dependence of sensitivity on the etched thickness and on neutron fluence, the effect of type and thickness of external proton emitters, and the effect of the choice of electric parameters on the resulting sensitivity in electrochemical etching. Good results were obtained when chemical and electrochemical etching was used in combination. It was found that with electrochemical etching, sensitivity decreases for neutron fluence exceeding 10 8 cm -2 . The sensitivity of the studied CR 39 polymer samples only little differed. When the most sensitive polymer was used, the minimum dose equivalent in the human body for Am-Be neutrons which could be determined using combination etching was 0.4 mSv (ie., 40 mrems). (B.S.)

  15. Lithium-drifted silicon detector with segmented contacts

    Science.gov (United States)

    Tindall, Craig S.; Luke, Paul N.

    2006-06-13

    A method and apparatus for creating both segmented and unsegmented radiation detectors which can operate at room temperature. The devices include a metal contact layer, and an n-type blocking contact formed from a thin layer of amorphous semiconductor. In one embodiment the material beneath the n-type contact is n-type material, such as lithium compensated silicon that forms the active region of the device. The active layer has been compensated to a degree at which the device may be fully depleted at low bias voltages. A p-type blocking contact layer, or a p-type donor material can be formed beneath a second metal contact layer to complete the device structure. When the contacts to the device are segmented, the device is capable of position sensitive detection and spectroscopy of ionizing radiation, such as photons, electrons, and ions.

  16. Sensitivity of neuroprogenitor cells to chemical-induced apoptosis using a multiplexed assay suitable for high-throughput screening

    International Nuclear Information System (INIS)

    Druwe, Ingrid; Freudenrich, Theresa M.; Wallace, Kathleen; Shafer, Timothy J.; Mundy, William R.

    2015-01-01

    High-throughput methods are useful for rapidly screening large numbers of chemicals for biological activity, including the perturbation of pathways that may lead to adverse cellular effects. In vitro assays for the key events of neurodevelopment, including apoptosis, may be used in a battery of tests for detecting chemicals that could result in developmental neurotoxicity. Apoptosis contributes to nervous system development by regulating the size of the neuroprogenitor cell pool, and the balance between cellular proliferation and apoptosis during neuroprogenitor cell proliferation helps to determine the size and shape of the nervous system. Therefore, chemicals that affect apoptosis during neuronal development can have deleterious effects on the developing brain. The present study examined the utility of a high-throughput assay to detect chemical-induced apoptosis in mouse or human neuroprogenitor cells, as well as differentiated human neurons derived from induced pluripotent stem cells. Apoptosis was assessed using an assay that measures enzymatic activity of caspase-3/7 in a rapid and cost efficient manner. The results show that all three commercially available models generated a robust source of proliferating neuroprogenitor cells, and that the assay was sensitive and reproducible when used in a multi-well plate format. There were differences in the response of rodent and human neuroprogenitor cells to a set of chemicals previously shown to induce apoptosis in vitro. Neuroprogenitor cells were more sensitive to chemical-induced apoptosis than differentiated neurons, suggesting that neuroprogenitor cells are one of the cell models that should be considered for use in a developmental neurotoxicity screening battery

  17. LSENS: A General Chemical Kinetics and Sensitivity Analysis Code for homogeneous gas-phase reactions. Part 1: Theory and numerical solution procedures

    Science.gov (United States)

    Radhakrishnan, Krishnan

    1994-01-01

    LSENS, the Lewis General Chemical Kinetics and Sensitivity Analysis Code, has been developed for solving complex, homogeneous, gas-phase chemical kinetics problems and contains sensitivity analysis for a variety of problems, including nonisothermal situations. This report is part 1 of a series of three reference publications that describe LENS, provide a detailed guide to its usage, and present many example problems. Part 1 derives the governing equations and describes the numerical solution procedures for the types of problems that can be solved. The accuracy and efficiency of LSENS are examined by means of various test problems, and comparisons with other methods and codes are presented. LSENS is a flexible, convenient, accurate, and efficient solver for chemical reaction problems such as static system; steady, one-dimensional, inviscid flow; reaction behind incident shock wave, including boundary layer correction; and perfectly stirred (highly backmixed) reactor. In addition, the chemical equilibrium state can be computed for the following assigned states: temperature and pressure, enthalpy and pressure, temperature and volume, and internal energy and volume. For static problems the code computes the sensitivity coefficients of the dependent variables and their temporal derivatives with respect to the initial values of the dependent variables and/or the three rate coefficient parameters of the chemical reactions.

  18. Adjoint sensitivity analysis applied on a model of irradiation assisted degradation of metals in aqueous systems

    International Nuclear Information System (INIS)

    Simonson, S.A.; Ballinger, R.G.; Christensen, R.A.

    1990-01-01

    Irradiation of an aqueous environment results, in general, in a steady state concentration of oxidizing chemical species in solution. Although the effect may be beneficial to the metal in contact with the solution in some cases, say by producing a more protective film, it is generally believed to be detrimental. The ability to predict the concentrations of the oxidizing species and from this begin to analyze the detrimental behavior on the metals requires computer codes that model the chemical reactions, production rates, and diffusion characteristics of the species being produced by irradiation. The large number of parameters and the complexity of the interactions involved in the predictions of irradiation effects on metals degradation requires a more sophisticated approach to determining the sensitivities of the final results. Monte Carlo techniques are too computationally intensive for practical use in determining sensitivities. The paper presents an approach, adjoint sensitivity analysis, that is more practical, i.e., three computer runs versus thousands, and also a more accurate measure of the sensitivities of the model

  19. Fragrance contact allergy

    DEFF Research Database (Denmark)

    Johansen, Jeanne D

    2003-01-01

    . This gives a positive patch-test reaction in about 10% of tested patients with eczema, and the most recent estimates show that 1.7-4.1% of the general population are sensitized to ingredients of the fragrance mix. Fragrance allergy occurs predominantly in women with facial or hand eczema. These women...... development to identify contact allergy to new allergens, reflecting the continuous developments and trends in exposure....

  20. Fabrication of surfaces with extremely high contact angle hysteresis from polyelectrolyte multilayer.

    Science.gov (United States)

    Wang, Liming; Wei, Jingjing; Su, Zhaohui

    2011-12-20

    High contact angle hysteresis on polyelectrolyte multilayers (PEMs) ion-paired with hydrophobic perfluorooctanoate anions is reported. Both the bilayer number of PEMs and the ionic strength of deposition solutions have significant influence on contact angle hysteresis: higher ionic strength and greater bilayer number cause increased contact angle hysteresis values. The hysteresis values of ~100° were observed on smooth PEMs and pinning of the receding contact line on hydrophilic defects is implicated as the cause of hysteresis. Surface roughness can be used to further tune the contact angle hysteresis on the PEMs. A surface with extremely high contact angle hysteresis of 156° was fabricated when a PEM was deposited on a rough substrate coated with submicrometer scale silica spheres. It was demonstrated that this extremely high value of contact angle hysteresis resulted from the penetration of water into the rough asperities on the substrate. The same substrate hydrophobized by chemical vapor deposition of 1H,1H,2H,2H-perfluorooctyltriethoxysilane exhibits high advancing contact angle and low hysteresis. © 2011 American Chemical Society

  1. The sensitivity of patch test in patients with psoriasis

    Directory of Open Access Journals (Sweden)

    Yavuz Yeşilova

    2010-09-01

    Full Text Available Objectives: Allergic diseases play an important role in the natural course of psoriasis. Atopic sensitization and con-tact dermatitis are common in patients with psoriasis. Since the symptoms are prolonged in patients who are resistant to therapy and exposure to itchy and external factors are common among these patients, the effects of contact aller-gens on triggering psoriasis are investigated. Contact allergens have an important role in activation and remission of psoriasis. We aimed to investigate contact sensitization rates in patients with psoriasis in the study.Material and Methods: Contact sensitization was investigated with the application of European standard series in twenty patients with psoriasis, twenty patients with contact dermatitis, and twenty healthy persons. Results: Among the whole study cases, positivity rate of patch test against one allergen at least was 25%. rate of patch test was 25% in patients with psoriasis, 35% in patients with contact dermatitis, and 15% in healthy persons. There were no significant differences between the groups according to sensitization to one or more allergens (p>0.05. There were no significant difference in clinical subgroup of psoriatic patients according to contact sensitiza-tion (p>0.05. The allergens in patients with psoriasis on patch test were as the followings: phenyldiamine, potassium dichromat, nickel, and cobalt.Conclusion: We think that the patch test has a major role in the diagnosis and elimination of allergens in patients with the chronic and resistant diseases and palmoplantar and flexural psoriasis.

  2. The identification of a sensitizing component used in the manufacturing of an ink ribbon

    Science.gov (United States)

    Anderson, Stacey E.; Tapp, Loren; Durgam, Srinivas; Meade, B. Jean; Jackson, Laurel G.; Cohen, David E.

    2015-01-01

    Skin diseases including dermatitis constitute ≈ 30% of all occupational illnesses, with a high incidence in the printing industry. An outbreak of contact dermatitis among employees at an ink ribbon manufacturing plant was investigated by scientists from the National Institute for Occupational Safety and Health (NIOSH). Employees in the process areas of the plant were exposed to numerous chemicals and many had experienced skin rashes, especially after the introduction of a new ink ribbon product. To identify the causative agent(s) of the occupational dermatitis, the murine local lymph node assay (LLNA) was used to identify the potential of the chemicals used in the manufacture of the ink ribbon to induce allergic contact dermatitis. Follow-up patch testing with the suspected allergens was conducted on exposed employees. Polyvinyl butyral, a chemical component used in the manufacture of the ink ribbon in question and other products, tested positive in the LLNA, with an EC3 of 3.6%, which identifies it as a potential sensitizer; however, no employees tested positive to this chemical during skin patch testing. This finding has implications beyond those described in this report because of occupational exposure to polyvinyl butyral outside of the printing industry. PMID:22375946

  3. Sesquiterpene lactone mix as a diagnostic tool for Asteraceae allergic contact dermatitis: chemical explanation for its poor performance and Sesquiterpene lactone mix II as a proposed improvement.

    Science.gov (United States)

    Jacob, Mathias; Brinkmann, Jürgen; Schmidt, Thomas J

    2012-05-01

    Two preparations are currently in use for the diagnosis of allergic contact dermatitis caused by Asteraceae: (i) Sesquiterpene lactone (SL) mix [three pure sesquiterpene lactones (STLs)], whose use has been questioned, owing to an insufficient rate of true-positive results; and (ii) Compositae mix, consisting of five Asteraceae extracts, which is problematic because of lack of standardization and questionable reproducibility. To analyse the reasons for the narrow sensitivity of SL mix from a chemoinformatic point of view, and to propose a solution by rational selection of alternative constituents for a new SL mix II covering a broader cohort of allergic patients. Structural and biological information on allergenic STLs was retrieved from databases and the literature, and molecular modelling and chemoinformatic computations were performed. An explanation for the insufficient hit rate of SL mix is that the three constituents possess extremely similar molecular structures/properties and do not represent well the structural diversity of allergenic STLs. STLs that are known as constituents of Compositae mix plants show much a wider diversity, which explains the higher positive rate. On the basis of their positions in chemical property space, a new collection of STLs that more evenly cover the overall structural diversity spectrum is proposed. SL mix II is likely to detect a larger number of patients sensitized to Asteraceae. © 2012 John Wiley & Sons A/S.

  4. The association between null mutations in the filaggrin gene and contact sensitization to nickel and other chemicals in the general population

    DEFF Research Database (Denmark)

    Thyssen, J P; Johansen, J D; Linneberg, A

    2010-01-01

    It was recently shown that filaggrin gene (FLG) null mutations are positively associated with nickel sensitization. We have hypothesized that histidine-rich filaggrin proteins in the epidermis chelate nickel ions and prevent their skin penetration and exposure to Langerhans cells. Furthermore, we...... have proposed that the low degree of genetic predisposition to nickel sensitization found by a Danish twin study was explained by a high prevalence of ear piercing among participants resulting in 'bypassing' of the filaggrin proteins....

  5. Allergic contact dermatitis from ophthalmic products: can pre-treatment with sodium lauryl sulfate increase patch test sensitivity?

    Science.gov (United States)

    Corazza, Monica; Virgili, Annarosa

    2005-05-01

    In patients suspected of allergic contact dermatitis because of topical ophthalmic medicaments, patch tests performed with patients' own products are often negative. The irritant anionic surfactant sodium lauryl sulfate (SLS) may alter the stratum corneum and increase antigen penetration. Pre-treatment of the skin with SLS 0.5% for 24 h was performed in the sites of patch tests with patients' own products in 15 selected patients. In patients previously negative to their own products tested with conventional patch tests, SLS pre-treatment showed 6 new relevant positive reactions and induced a stronger positive reaction in 1 patient. SLS pre-treatment could be proposed as an alternative promising method, which may increase sensitivity of patch tests with patients' own products.

  6. Assessment of the skin sensitization potency of eugenol and its dimers using a non-radioisotopic modification of the local lymph node assay.

    Science.gov (United States)

    Takeyoshi, Masahiro; Noda, Shuji; Yamazaki, Shunsuke; Kakishima, Hiroshi; Yamasaki, Kanji; Kimber, Ian

    2004-01-01

    Allergic contact dermatitis is a serious health problem. There is a need to identify and characterize skin sensitization hazards, particularly with respect to relative potency, so that accurate risk assessments can be developed. For these purposes the murine local lymph node assay (LLNA) was developed. Here, we have investigated further a modi fi cation of this assay, non-radioisotopic LLNA, which in place of tritiated thymidine to measure lymph node cell proliferation employs incorporation of 5-bromo-2'-deoxyuridine. Using this method we have examined the skin sensitizing activity of eugenol, a known human contact allergen, and its dimers 2,2'-dihydroxyl-3,3'-dimethoxy-5,5'-diallyl-biphenyl (DHEA) and 4,5'-diallyl-2'-hydroxy-2,3'-dimethoxy phenyl ether (DHEB). Activity in the guinea pig maximization test (GPMT) also measured. On the basis of GPMT assays, eugenol was classified as a mild skin sensitizer, DHEA as a weak skin sensitizer and DHEB as an extreme skin sensitizer. In the non-radioisotopic LLNA all chemicals were found to give positive responses insofar as each was able to provoke a stimulation index (SI) of >or=3 at one or more test concentrations. The relative skin sensitizing potency of these chemicals was evaluated in the non-radioisotopic LLNA by derivation of an ec(3) value (the concentration of chemical required to provoke an SI of 3). The ec(3) values calculated were 25.1% for eugenol, >30% for DHEA and 2.3% for DHEB. Collectively these data suggest that assessments of relative potency deriving from non-radioisotopic LLNA responses correlate well with evaluations based on GPMT results. These investigations provide support for the proposal that the non-radioisotopic LLNA may serve as an effective alternative to the GPMT where there is a need to avoid the use of radioisotopes. Copyright 2004 John Wiley & Sons, Ltd.

  7. Prevalence, incidence rates and persistence of contact allergy and allergic contact dermatitis in The Odense Adolescence Cohort Study: a 15-year follow-up

    DEFF Research Database (Denmark)

    Mortz, C. G.; Bindslev-Jensen, C.; Andersen, Klaus Ejner

    2013-01-01

    BACKGROUND: A cohort of 1501 unselected 8th grade schoolchildren was established 15 years ago with the aim to follow the course of contact allergy and allergic contact dermatitis (ACD) from school age into adult life. To date no studies have evaluated incidence rates and persistence of contact al...... the most common contact allergen, and new sensitizations occurred despite the European Union nickel regulation. Fragrance mix I was a poor marker for history of eczematous skin reaction to perfumed products....

  8. Sensitivity of ab Initio vs Empirical Methods in Computing Structural Effects on NMR Chemical Shifts for the Example of Peptides.

    Science.gov (United States)

    Sumowski, Chris Vanessa; Hanni, Matti; Schweizer, Sabine; Ochsenfeld, Christian

    2014-01-14

    The structural sensitivity of NMR chemical shifts as computed by quantum chemical methods is compared to a variety of empirical approaches for the example of a prototypical peptide, the 38-residue kaliotoxin KTX comprising 573 atoms. Despite the simplicity of empirical chemical shift prediction programs, the agreement with experimental results is rather good, underlining their usefulness. However, we show in our present work that they are highly insensitive to structural changes, which renders their use for validating predicted structures questionable. In contrast, quantum chemical methods show the expected high sensitivity to structural and electronic changes. This appears to be independent of the quantum chemical approach or the inclusion of solvent effects. For the latter, explicit solvent simulations with increasing number of snapshots were performed for two conformers of an eight amino acid sequence. In conclusion, the empirical approaches neither provide the expected magnitude nor the patterns of NMR chemical shifts determined by the clearly more costly ab initio methods upon structural changes. This restricts the use of empirical prediction programs in studies where peptide and protein structures are utilized for the NMR chemical shift evaluation such as in NMR refinement processes, structural model verifications, or calculations of NMR nuclear spin relaxation rates.

  9. Highly sensitive refractive index fiber inline Mach-Zehnder interferometer fabricated by femtosecond laser micromachining and chemical etching

    Science.gov (United States)

    Sun, Xiao-Yan; Chu, Dong-Kai; Dong, Xin-Ran; Zhou, Chu; Li, Hai-Tao; Luo-Zhi; Hu, You-Wang; Zhou, Jian-Ying; Cong-Wang; Duan, Ji-An

    2016-03-01

    A High sensitive refractive index (RI) sensor based on Mach-Zehnder interferometer (MZI) in a conventional single-mode optical fiber is proposed, which is fabricated by femtosecond laser transversal-scanning inscription method and chemical etching. A rectangular cavity structure is formed in part of fiber core and cladding interface. The MZI sensor shows excellent refractive index sensitivity and linearity, which exhibits an extremely high RI sensitivity of -17197 nm/RIU (refractive index unit) with the linearity of 0.9996 within the refractive index range of 1.3371-1.3407. The experimental results are consistent with theoretical analysis.

  10. Multiple chemical sensitivity, en veldefineret lidelse?

    DEFF Research Database (Denmark)

    Kolstad, Henrik A.; Silberschmidt, Martin; Nielsen, Jesper Bo

    2006-01-01

    , even though a number of theories have been proposed. The authors of this review conclude that this is a functional condition. These patients need information and treatment in accordance with this fact. Instead of being advised how to avoid exposure to chemicals, they should be properly trained...... in appropriate confrontation with the chemicals encountered in everyday life....

  11. [Type IV contact allergies in the food processing industry: an update].

    Science.gov (United States)

    Bauer, A; Schubert, S; Geier, J; Mahler, V

    2018-05-02

    The food sector is one of the high-risk areas for occupational irritative and allergic contact eczema. The present work provides an overview of the main allergens as well as sensitization frequencies and risk in various food industry occupations. The literature on type IV sensitization in the food sector is summarized. The relative risk of developing a work-related eczema in food processing is increased by more than 3 times. The comparison group was calculated on the basis of the proportion of documented cases in the IVDK (Informationsverbund Dermatologischer Kliniken) network per 100,000 working persons in relation to the average of the years 2005 and 2010. For this purpose, the average risk of all patients was set as reference to 1. Bakers, pastry chefs, cooks and meat and fish processors are mainly affected. In addition to irritant contact eczema, allergic contact eczema and protein contact dermatitis often occur. Leading haptens (main allergens) are rubber ingredients, but also disinfectants and compositae. Only a few contact allergens are responsible for the majority of job-relevant sensitizations in the food industry.

  12. Effect of contact with male on the physical and chemical qualities of ...

    African Journals Online (AJOL)

    A group of 30 Black HARCO laying hens were reared together with 3 mature cocks, while another group were reared in an adjacent pen without cocks. Thus, while the first group of hens had full physical contact (including mating) with the males, the second group was restricted only to auditory and visual contacts with the ...

  13. Non-specific chemical inhibition of the Fanconi anemia pathway sensitizes cancer cells to cisplatin

    Directory of Open Access Journals (Sweden)

    Jacquemont Céline

    2012-04-01

    Full Text Available Abstract Background Platinum compounds such as cisplatin and carboplatin are DNA crosslinking agents widely used for cancer chemotherapy. However, the effectiveness of platinum compounds is often tempered by the acquisition of cellular drug resistance. Until now, no pharmacological approach has successfully overcome cisplatin resistance in cancer treatment. Since the Fanconi anemia (FA pathway is a DNA damage response pathway required for cellular resistance to DNA interstrand crosslinking agents, identification of small molecules that inhibit the FA pathway may reveal classes of chemicals that sensitize cancer cells to cisplatin. Results Through a cell-based screening assay of over 16,000 chemicals, we identified 26 small molecules that inhibit ionizing radiation and cisplatin-induced FANCD2 foci formation, a marker of FA pathway activity, in multiple human cell lines. Most of these small molecules also compromised ionizing radiation-induced RAD51 foci formation and homologous recombination repair, indicating that they are not selective toward the regulation of FANCD2. These compounds include known inhibitors of the proteasome, cathepsin B, lysosome, CHK1, HSP90, CDK and PKC, and several uncharacterized chemicals including a novel proteasome inhibitor (Chembridge compound 5929407. Isobologram analyses demonstrated that half of the identified molecules sensitized ovarian cancer cells to cisplatin. Among them, 9 demonstrated increased efficiency toward FA pathway-proficient, cisplatin-resistant ovarian cancer cells. Six small molecules, including bortezomib (proteasome inhibitor, CA-074-Me (cathepsin B inhibitor and 17-AAG (HSP90 inhibitor, synergized with cisplatin specifically in FA-proficient ovarian cancer cells (2008 + FANCF, but not in FA-deficient isogenic cells (2008. In addition, geldanamycin (HSP90 inhibitor and two CHK1 inhibitors (UCN-01 and SB218078 exhibited a significantly stronger synergism with cisplatin in FA

  14. Large area optical mapping of surface contact angle.

    Science.gov (United States)

    Dutra, Guilherme; Canning, John; Padden, Whayne; Martelli, Cicero; Dligatch, Svetlana

    2017-09-04

    Top-down contact angle measurements have been validated and confirmed to be as good if not more reliable than side-based measurements. A range of samples, including industrially relevant materials for roofing and printing, has been compared. Using the top-down approach, mapping in both 1-D and 2-D has been demonstrated. The method was applied to study the change in contact angle as a function of change in silver (Ag) nanoparticle size controlled by thermal evaporation. Large area mapping reveals good uniformity for commercial Aspen paper coated with black laser printer ink. A demonstration of the forensic and chemical analysis potential in 2-D is shown by uncovering the hidden CsF initials made with mineral oil on the coated Aspen paper. The method promises to revolutionize nanoscale characterization and industrial monitoring as well as chemical analyses by allowing rapid contact angle measurements over large areas or large numbers of samples in ways and times that have not been possible before.

  15. Allergic contact dermatitis mimicking angioedema due to paraphenylendiamine hypersensitivity: a case report.

    Science.gov (United States)

    Tukenmez Demirci, Gulsen; Kivanc Altunay, Ilknur; Atis, Guldehan; Kucukunal, Asli

    2012-09-01

    Active sensitization to paraphenylendiamine (PPD) and related compounds from temporary black henna tattoos has become an epidemic in the recent years. Hair dyes also include PPD like black henna tatoos which cause allergic contact dermatitis. Skin lesions of allergic contact dermatitis from PPD are mostly seen as an exudative erythema, an erythema multiforme-like eruption or a bullous contact dermatitis. We, herein, report a 27 year-old woman with an angioedema-like reaction occurring after the first exposure to hair dye who was unaware of being previously sensitized to PPD from black henna tattoo.

  16. Direct measurements of intermolecular forces by chemical force microscopy

    Science.gov (United States)

    Vezenov, Dmitri Vitalievich

    1999-12-01

    Detailed description of intermolecular forces is key to understanding a wide range of phenomena from molecular recognition to materials failure. The unique features of atomic force microscopy (AFM) to make point contact force measurements with ultra high sensitivity and to generate spatial maps of surface topography and forces have been extended to include measurements between well-defined organic molecular groups. Chemical modification of AFM probes with self-assembled monolayers (SAMs) was used to make them sensitive to specific molecular interactions. This novel chemical force microscopy (CFM) technique was used to probe forces between different molecular groups in a range of environments (vacuum, organic liquids and aqueous solutions); measure surface energetics on a nanometer scale; determine pK values of the surface acid and base groups; measure forces to stretch and unbind a short synthetic DNA duplex and map the spatial distribution of specific functional groups and their ionization state. Studies of adhesion forces demonstrated the important contribution of hydrogen bonding to interactions between simple organic functionalities. The chemical identity of the tip and substrate surfaces as well as the medium had a dramatic effect on adhesion between model monolayers. A direct correlation between surface free energy and adhesion forces was established. The adhesion between epoxy polymer and model mixed SAMs varied with the amount of hydrogen bonding component in the monolayers. A consistent interpretation of CFM measurements in polar solvents was provided by contact mechanics models and intermolecular force components theory. Forces between tips and surfaces functionalized with SAMs terminating in acid or base groups depended on their ionization state. A novel method of force titration was introduced for highly local characterization of the pK's of surface functional groups. The pH-dependent changes in friction forces were exploited to map spatially the

  17. An 8.68% efficiency chemically-doped-free graphene-silicon solar cell using silver nanowires network buried contacts.

    Science.gov (United States)

    Yang, Lifei; Yu, Xuegong; Hu, Weidan; Wu, Xiaolei; Zhao, Yan; Yang, Deren

    2015-02-25

    Graphene-silicon (Gr-Si) heterojunction solar cells have been recognized as one of the most low-cost candidates in photovoltaics due to its simple fabrication process. However, the high sheet resistance of chemical vapor deposited (CVD) Gr films is still the most important limiting factor for the improvement of the power conversion efficiency of Gr-Si solar cells, especially in the case of large device-active area. In this work, we have fabricated a novel transparent conductive film by hybriding a monolayer Gr film with silver nanowires (AgNWs) network soldered by the graphene oxide (GO) flakes. This Gr-AgNWs hybrid film exhibits low sheet resistance and larger direct-current to optical conductivity ratio, quite suitable for solar cell fabrication. An efficiency of 8.68% has been achieved for the Gr-AgNWs-Si solar cell, in which the AgNWs network acts as buried contacts. Meanwhile, the Gr-AgNWs-Si solar cells have much better stability than the chemically doped Gr-Si solar cells. These results show a new route for the fabrication of high efficient and stable Gr-Si solar cells.

  18. Occupational allergic contact dermatitis in a 2-year follow-up study

    DEFF Research Database (Denmark)

    Brok, Line; Clemmensen, Kim Katrine Bjerring; Carøe, Tanja Korfitsen

    2016-01-01

    BACKGROUND: Patch testing is mandatory for diagnosing contact dermatitis. It is, however, crucial that patients understand and remember the result of the test. OBJECTIVES: The aim of our study was to evaluate the impact of patch testing with respect to patients' ability to remember patch test...... results and the results of natural rubber latex protein allergy after 2 years. METHODS: One hundred and ninety-nine patients diagnosed with relevant occupational epoxy or rubber chemical contact allergy, or allergy to natural rubber latex protein, were invited to participate in a questionnaire study about...... their knowledge of contact allergies after 2 years. RESULTS: The response rate was 75%. Of the respondents, 13% did not remember their occupational contact allergy to rubber chemicals or epoxy. Ability to remember was not significantly influenced by sex or Dermatology Life Quality Index, but was decreased by age...

  19. An in-fiber Bragg grating sensor for contact force and stress measurements in articular joints

    International Nuclear Information System (INIS)

    Dennison, Christopher R; Wild, Peter M; Wilson, David R; Gilbart, Michael K

    2010-01-01

    We present an in-fiber Bragg grating-based sensor (240 µm diameter) for contact force/stress measurements in articular joints. The contact force sensor and another Bragg grating-based pressure sensor (400 µm diameter) are used to conduct the first simultaneous measurements of contact force/stress and fluid pressure in intact cadaveric human hips. The contact force/stress sensor addresses limitations associated with stress-sensitive films, the current standard tools for contact measurements in joints, including cartilage modulus-dependent sensitivity of films and the necessity to remove biomechanically relevant anatomy to implant the films. Because stress-sensitive films require removal of anatomy, it has been impossible to validate the mechanical rationale underlying preventive or corrective surgeries, which repair these anatomies, by conducting simultaneous stress and pressure measurements in intact hips. Methods are presented to insert the Bragg grating-based sensors into the joint, while relevant anatomy is left largely intact. Sensor performance is predicted using numerical models and the predicted sensitivity is verified through experimental calibrations. Contact force/stress and pressure measurements in cadaveric joints exhibited repeatability. With further validation, the Bragg grating-based sensors could be used to study the currently unknown relationships between contact forces and pressures in both healthy and degenerated joints

  20. Sensitivity enhancement of chemically amplified resists and performance study using EUV interference lithography

    Science.gov (United States)

    Buitrago, Elizabeth; Nagahara, Seiji; Yildirim, Oktay; Nakagawa, Hisashi; Tagawa, Seiichi; Meeuwissen, Marieke; Nagai, Tomoki; Naruoka, Takehiko; Verspaget, Coen; Hoefnagels, Rik; Rispens, Gijsbert; Shiraishi, Gosuke; Terashita, Yuichi; Minekawa, Yukie; Yoshihara, Kosuke; Oshima, Akihiro; Vockenhuber, Michaela; Ekinci, Yasin

    2016-03-01

    Extreme ultraviolet lithography (EUVL, λ = 13.5 nm) is the most promising candidate to manufacture electronic devices for future technology nodes in the semiconductor industry. Nonetheless, EUVL still faces many technological challenges as it moves toward high-volume manufacturing (HVM). A key bottleneck from the tool design and performance point of view has been the development of an efficient, high power EUV light source for high throughput production. Consequently, there has been extensive research on different methodologies to enhance EUV resist sensitivity. Resist performance is measured in terms of its ultimate printing resolution, line width roughness (LWR), sensitivity (S or best energy BE) and exposure latitude (EL). However, there are well-known fundamental trade-off relationships (LRS trade-off) among these parameters for chemically amplified resists (CARs). Here we present early proof-of-principle results for a multi-exposure lithography process that has the potential for high sensitivity enhancement without compromising other important performance characteristics by the use of a Photosensitized Chemically Amplified Resist (PSCAR). With this method, we seek to increase the sensitivity by combining a first EUV pattern exposure with a second UV flood exposure (λ = 365 nm) and the use of a PSCAR. In addition, we have evaluated over 50 different state-of-the-art EUV CARs. Among these, we have identified several promising candidates that simultaneously meet sensitivity, LWR and EL high performance requirements with the aim of resolving line space (L/S) features for the 7 and 5 nm logic node (16 nm and 13 nm half-pitch HP, respectively) for HVM. Several CARs were additionally found to be well resolved down to 12 nm and 11 nm HP with minimal pattern collapse and bridging, a remarkable feat for CARs. Finally, the performance of two negative tone state-of-the-art alternative resist platforms previously investigated was compared to the CAR performance at and

  1. Gallate Contact Dermatitis: Product Update and Systematic Review.

    Science.gov (United States)

    Holcomb, Zachary E; Van Noord, Megan G; Atwater, Amber Reck

    Allergic contact dermatitis related to cosmetic use can result from allergens not routinely evaluated by standard patch test protocols. Propyl, octyl, and dodecyl gallates are commonly used antioxidant preservatives with reports of associated allergic contact dermatitis in the literature. The objectives of this review were to investigate the role of gallates in allergic contact dermatitis and to explore products containing these preservatives. A systematic review of the literature through April 2016 was performed to explore cases of reported gallate allergy. Food and cosmetic product databases were searched for products containing gallates. Seventy-four cases of gallate contact allergy have been reported. In addition, a variety of commercially available cosmetic products and foods contain gallate chemicals. Propyl gallate is the most commonly reported gallate contact allergen and often causes facial and/or hand dermatitis.

  2. Contact mechanics: contact area and interfacial separation from small contact to full contact

    International Nuclear Information System (INIS)

    Yang, C; Persson, B N J

    2008-01-01

    We present a molecular dynamics study of the contact between a rigid solid with a randomly rough surface and an elastic block with a flat surface. The numerical calculations mainly focus on the contact area and the interfacial separation from small contact (low load) to full contact (high load). For a small load the contact area varies linearly with the load and the interfacial separation depends logarithmically on the load. For a high load the contact area approaches the nominal contact area (i.e. complete contact), and the interfacial separation approaches zero. The numerical results have been compared with analytical theory and experimental results. They are in good agreement with each other. The present findings may be very important for soft solids, e.g. rubber, or for very smooth surfaces, where complete contact can be reached at moderately high loads without plastic deformation of the solids

  3. Proteomics analysis of dendritic cell activation by contact allergens reveals possible biomarkers regulated by Nrf2

    Energy Technology Data Exchange (ETDEWEB)

    Mussotter, Franz, E-mail: franz.mussotter@bfr.bund.de [German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Berlin (Germany); Tomm, Janina Melanie [Helmholtz Centre for Environmental Research (UFZ), Department of Molecular Systems Biology, Leipzig (Germany); El Ali, Zeina; Pallardy, Marc; Kerdine-Römer, Saadia [INSERM UMR 996, Univ Paris-Sud, Université Paris-Saclay, Chátenay-Malabry (France); Götz, Mario [German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Berlin (Germany); Bergen, Martin von [Helmholtz Centre for Environmental Research (UFZ), Department of Molecular Systems Biology, Leipzig (Germany); University of Leipzig, Institute of Biochemistry, Leipzig (Germany); Aalborg University, Department of Chemistry and Bioscience, Aalborg (Denmark); Haase, Andrea; Luch, Andreas [German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Berlin (Germany)

    2016-12-15

    Allergic contact dermatitis is a widespread disease with high clinical relevance affecting approximately 20% of the general population. Typically, contact allergens are low molecular weight electrophilic compounds which can activate the Keap1/Nrf2 pathway. We performed a proteomics study to reveal possible biomarkers for dendritic cell (DC) activation by contact allergens and to further elucidate the role of Keap1/Nrf2 signaling in this process. We used bone marrow derived dendritic cells (BMDCs) of wild-type (nrf2{sup +/+}) and Nrf2 knockout (nrf2{sup −/−}) mice and studied their response against the model contact sensitizers 2,4-dinitrochlorobenzene (DNCB), cinnamaldehyde (CA) and nickel(II) sulfate by 2-dimensional polyacrylamide gel electrophoresis (2D-PAGE) in combination with electrospray ionization tandem mass spectrometry (ESI-MS/MS). Sodium dodecyl sulfate (SDS, 100 μM) served as irritant control. While treatment with nickel(II) sulfate and SDS had only little effects, CA and DNCB led to significant changes in protein expression. We found 18 and 30 protein spots up-regulated in wild-type cells treated with 50 and 100 μM CA, respectively. For 5 and 10 μM DNCB, 32 and 37 spots were up-regulated, respectively. Almost all of these proteins were not differentially expressed in nrf2{sup −/−} BMDCs, indicating an Nrf2-dependent regulation. Among them proteins were detected which are involved in oxidative stress and heat shock responses, as well as in signal transduction or basic cellular pathways. The applied approach allowed us to differentiate between Nrf2-dependent and Nrf2-independent cellular biomarkers differentially regulated upon allergen-induced DC activation. The data presented might contribute to the further development of suitable in vitro testing methods for chemical-mediated sensitization. - Highlights: • Contact allergens induce proteins involved in DC maturation Nrf2-dependently. • Induction of these proteins points to a functional

  4. Quantitative sub-surface and non-contact imaging using scanning microwave microscopy

    International Nuclear Information System (INIS)

    Gramse, Georg; Kasper, Manuel; Hinterdorfer, Peter; Brinciotti, Enrico; Rankl, Christian; Kienberger, Ferry; Lucibello, Andrea; Marcelli, Romolo; Patil, Samadhan B.; Giridharagopal, Rajiv

    2015-01-01

    The capability of scanning microwave microscopy for calibrated sub-surface and non-contact capacitance imaging of silicon (Si) samples is quantitatively studied at broadband frequencies ranging from 1 to 20 GHz. Calibrated capacitance images of flat Si test samples with varying dopant density (10 15 –10 19 atoms cm −3 ) and covered with dielectric thin films of SiO 2 (100–400 nm thickness) are measured to demonstrate the sensitivity of scanning microwave microscopy (SMM) for sub-surface imaging. Using standard SMM imaging conditions the dopant areas could still be sensed under a 400 nm thick oxide layer. Non-contact SMM imaging in lift-mode and constant height mode is quantitatively demonstrated on a 50 nm thick SiO 2 test pad. The differences between non-contact and contact mode capacitances are studied with respect to the main parameters influencing the imaging contrast, namely the probe tip diameter and the tip–sample distance. Finite element modelling was used to further analyse the influence of the tip radius and the tip–sample distance on the SMM sensitivity. The understanding of how the two key parameters determine the SMM sensitivity and quantitative capacitances represents an important step towards its routine application for non-contact and sub-surface imaging. (paper)

  5. Artificial pupil versus contralateral balanced contact lens fit for presbyopia correction

    Directory of Open Access Journals (Sweden)

    Santiago García-Lázaro

    2014-04-01

    Full Text Available Purpose: To assess and compare the effects of contact lens-based artificial pupil design and contralateral balanced multifocal contact lens combination (CBMCLC on visual performance. Methods: This randomized crossover study conducted at the University of Valencia, Spain included 38 presbyopic patients using an artificial pupil contact lens in the nondominant eye and a CBMCLC. After a month of lens wear, the binocular distance visual acuity (BDVA, binocular near visual acuity (BNVA, defocus curve, binocular distance, and near contrast sensitivity and near stereoacuity (NSA were measured under photopic conditions (85 cd/m2. Moreover, BDVA and binocular distance contrast sensitivity were examined under mesopic conditions (5 cd/m2. Results: Visual acuity at an intermediate distance and near vision was better with the CBMCLC than with the artificial pupil (p<0.05. Statistically significant differences were found in contrast sensitivity between the two types of correction for distance (under mesopic conditions and for near vision, with the CBMCLC exhibiting better results in both cases (p<0.05. The mean NSA values obtained for the artificial pupil contact lens were significantly worse than those for the CBMCLC (p=0.001. Conclusion: The CBMCLC provided greater visual performance in terms of intermediate and near vision compared with the artificial pupil contact lens.

  6. Flexible textile-based strain sensor induced by contacts

    International Nuclear Information System (INIS)

    Zhang, Hui

    2015-01-01

    In this paper, the contact effects are used as the key sensing element to develop flexible textile-structured strain sensors. The structures of the contact are analyzed theoretically and the contact resistances are investigated experimentally. The electromechanical properties of the textiles are investigated to find the key factors which determine the sensitivity, repeatability, and linearity of the sensor. The sensing mechanism is based on the change of contact resistance induced by the change of the configuration of the textiles. In order to improve the performance of the textile strain sensor, the contact resistance is designed based on the electromechanical properties of the fabric. It can be seen from the results that the performance of the sensor is largely affected by the structure of the contacts, which are determined by the morphology of fiber surface and the structures of the yarn and fabric. (paper)

  7. Contact parameter identification for vibrational response variability prediction

    DEFF Research Database (Denmark)

    Creixell Mediante, Ester; Brunskog, Jonas; Jensen, Jakob Søndergaard

    2018-01-01

    industry, where the vibrational behavior of the structures within the hearing frequency range is critical for the performance of the devices. A procedure to localize the most probable contact areas and determine the most sensitive contact points with respect to variations in the modes of vibration......Variability in the dynamic response of assembled structures can arise due to variations in the contact conditions between the parts that conform them. Contact conditions are difficult to model accurately due to randomness in physical properties such as contact surface, load distribution...... or geometric details. Those properties can vary for a given structure due to the assembly and disassembly process, and also across nominally equal items that are produced in series. This work focuses on modeling the contact between small light-weight plastic pieces such as those used in the hearing aid...

  8. Rapid and sensitive reporter gene assays for detection of antiandrogenic and estrogenic effects of environmental chemicals

    DEFF Research Database (Denmark)

    Vinggaard, Anne; Jørgensen, E.C.B.; Larsen, John Christian

    1999-01-01

    Reports on increasing incidences in developmental abnormalities of the human male reproductive tract and the recent identifications of environmental chemicals with antiandrogenic activity necessitate the screening of a larger number of compounds in order to get an overview of potential antiandrog......Reports on increasing incidences in developmental abnormalities of the human male reproductive tract and the recent identifications of environmental chemicals with antiandrogenic activity necessitate the screening of a larger number of compounds in order to get an overview of potential...... antiandrogenic chemicals present in our environment. Thus, there is a great need for an effective in vitro screening method for (anti)androgenic chemicals. We have developed a rapid, sensitive, and reproducible reporter gene assay for detection of antiandrogenic chemicals. Chinese Hamster Ovary cells were...... calcium phosphate transfection method, this method has the advantage of being more feasible, as the assay can be scaled down to the microtiter plate format. Furthermore, the transfection reagent is noncytotoxic, allowing its addition together with the test compounds thereby reducing the hands...

  9. Sensitivity enhancement of chemically amplified resists and performance study using extreme ultraviolet interference lithography

    Science.gov (United States)

    Buitrago, Elizabeth; Nagahara, Seiji; Yildirim, Oktay; Nakagawa, Hisashi; Tagawa, Seiichi; Meeuwissen, Marieke; Nagai, Tomoki; Naruoka, Takehiko; Verspaget, Coen; Hoefnagels, Rik; Rispens, Gijsbert; Shiraishi, Gosuke; Terashita, Yuichi; Minekawa, Yukie; Yoshihara, Kosuke; Oshima, Akihiro; Vockenhuber, Michaela; Ekinci, Yasin

    2016-07-01

    Extreme ultraviolet lithography (EUVL, λ=13.5 nm) is the most promising candidate to manufacture electronic devices for future technology nodes in the semiconductor industry. Nonetheless, EUVL still faces many technological challenges as it moves toward high-volume manufacturing (HVM). A key bottleneck from the tool design and performance point of view has been the development of an efficient, high-power EUV light source for high throughput production. Consequently, there has been extensive research on different methodologies to enhance EUV resist sensitivity. Resist performance is measured in terms of its ultimate printing resolution, line width roughness (LWR), sensitivity [S or best energy (BE)], and exposure latitude (EL). However, there are well-known fundamental trade-off relationships (line width roughness, resolution and sensitivity trade-off) among these parameters for chemically amplified resists (CARs). We present early proof-of-principle results for a multiexposure lithography process that has the potential for high sensitivity enhancement without compromising other important performance characteristics by the use of a "Photosensitized Chemically Amplified Resist™" (PSCAR™). With this method, we seek to increase the sensitivity by combining a first EUV pattern exposure with a second UV-flood exposure (λ=365 nm) and the use of a PSCAR. In addition, we have evaluated over 50 different state-of-the-art EUV CARs. Among these, we have identified several promising candidates that simultaneously meet sensitivity, LWR, and EL high-performance requirements with the aim of resolving line space (L/S) features for the 7- and 5-nm logic node [16- and 13-nm half-pitch (HP), respectively] for HVM. Several CARs were additionally found to be well resolved down to 12- and 11-nm HP with minimal pattern collapse and bridging, a remarkable feat for CARs. Finally, the performance of two negative tone state-of-the-art alternative resist platforms previously investigated

  10. Amino acid empirical contact energy definitions for fold recognition in the space of contact maps

    Directory of Open Access Journals (Sweden)

    Fogolari Federico

    2003-02-01

    Full Text Available Abstract Background Contradicting evidence has been presented in the literature concerning the effectiveness of empirical contact energies for fold recognition. Empirical contact energies are calculated on the basis of information available from selected protein structures, with respect to a defined reference state, according to the quasi-chemical approximation. Protein-solvent interactions are estimated from residue solvent accessibility. Results In the approach presented here, contact energies are derived from the potential of mean force theory, several definitions of contact are examined and their performance in fold recognition is evaluated on sets of decoy structures. The best definition of contact is tested, on a more realistic scenario, on all predictions including sidechains accepted in the CASP4 experiment. In 30 out of 35 cases the native structure is correctly recognized and best predictions are usually found among the 10 lowest energy predictions. Conclusion The definition of contact based on van der Waals radii of alpha carbon and side chain heavy atoms is seen to perform better than other definitions involving only alpha carbons, only beta carbons, all heavy atoms or only backbone atoms. An important prerequisite for the applicability of the approach is that the protein structure under study should not exhibit anomalous solvent accessibility, compared to soluble proteins whose structure is deposited in the Protein Data Bank. The combined evaluation of a solvent accessibility parameter and contact energy allows for an effective gross screening of predictive models.

  11. Low-Cost Chemical-Responsive Adhesive Sensing Chips.

    Science.gov (United States)

    Tan, Weirui; Zhang, Liyuan; Shen, Wei

    2017-12-06

    Chemical-responsive adhesive sensing chip is a new low-cost analytical platform that uses adhesive tape loaded with indicator reagents to detect or quantify the target analytes by directly sticking the tape to the samples of interest. The chemical-responsive adhesive sensing chips can be used with paper to analyze aqueous samples; they can also be used to detect and quantify solid, particulate, and powder analytes. The colorimetric indicators become immediately visible as the contact between the functionalized adhesives and target samples is made. The chemical-responsive adhesive sensing chip expands the capability of paper-based analytical devices to analyze solid, particulate, or powder materials via one-step operation. It is also a simpler alternative way, to the covalent chemical modification of paper, to eliminate indicator leaching from the dipstick-style paper sensors. Chemical-responsive adhesive chips can display analytical results in the form of colorimetric dot patterns, symbols, and texts, enabling clear understanding of assay results by even nonprofessional users. In this work, we demonstrate the analyses of heavy metal salts in silica powder matrix, heavy metal ions in water, and bovine serum albumin in an aqueous solution. The detection is one-step, specific, sensitive, and easy-to-operate.

  12. Further important sensitizers in patients sensitive to fragrances.

    Science.gov (United States)

    Frosch, P J; Johansen, J D; Menné, T; Pirker, C; Rastogi, S C; Andersen, K E; Bruze, M; Goossens, A; Lepoittevin, J P; White, I R

    2002-08-01

    The aim of this study was to determine the frequency of responses to selected fragrance materials in consecutive patients patch tested in 6 dermatological centres in Europe. 1855 patients were evaluated with the 8% fragrance mix (FM) and 14 other frequently used well-defined fragrance chemicals (series I). Each patient was classified regarding a history of adverse reactions to fragrances: certain, probable, questionable, none. Reactions to FM occurred in 11.3% of the subjects. The 6 substances with the highest reactivity following FM were Lyral (2.7%), citral (1.1%), farnesol P (0.5%), citronellol (0.4%), hexyl cinnamic aldehyde (0.3%), and coumarin (0.3%). 41 (2.2%) of the patients reacted only to materials of series I and not to FM. 6.6% of 1855 patients gave a history of adverse reactions to fragrances which was classified as certain. This group reacted to FM only in 41.1%, to series I and FM in 12.0% and to series I only in 7.2%. 74.3% of the 39 patients reacting to both FM and 1 of the materials of series I had any type of positive fragrance history, which was significantly higher in comparison to those with isolated reactions to series I (53.6% of 41), p = 0.04. The study identified further sensitizers relevant for patch testing of patients with contact dermatitis, of which Lyral is the most important single chemical.

  13. Enhanced expression of IL-8 in normal human keratinocytes and human keratinocyte cell line HaCaT in vitro after stimulation with contact sensitizers, tolerogens and irritants.

    Science.gov (United States)

    Mohamadzadeh, M; Müller, M; Hultsch, T; Enk, A; Saloga, J; Knop, J

    1994-12-01

    To investigate the interleukin-8 production of keratinocytes after stimulation in vitro we have used various agents: (i) contact sensitizer (2,4-dinitrofluorobenzene, 3-n-pentadecylcatechol); (ii) tolerogen (5-methyl-3-n-pentadecylcatechol); (iii) irritant (sodium lauryl sulfate). Interleukin-8 gene expression was assessed by northern blot hybridization of the total cytoplasmic RNA extracted from subconfluent normal human keratinocyte cultures and the keratinocyte cell line HaCaT using a radiolabeled DNA probe specific for human interleukin-8. Interleukin-8 gene expression was markedly increased upon in vitro stimulation after 1-6 h with contact sensitizers, tolerogen and the irritant. In contrast, interleukin-8 production was not detectable in unstimulated normal human keratinocytes or the HaCaT keratinocyte cell line. These results suggest that the induction and production of interleukin-8 is a response to nonspecific stimuli and may play a critical role in the early response to immunogenic or inflammatory signals in man.

  14. Argonne Chemical Sciences & Engineering - Awards Home

    Science.gov (United States)

    Argonne National Laboratory Chemical Sciences & Engineering DOE Logo CSE Home About CSE Argonne Home > Chemical Sciences & Engineering > Fundamental Interactions Catalysis & Energy Computational Postdoctoral Fellowships Contact Us CSE Intranet Awards Argonne's Chemical Sciences and

  15. The role of contacts in semiconductor gamma radiation detectors

    International Nuclear Information System (INIS)

    Lachish, U.

    1998-01-01

    It is proposed that the operation of semiconductor gamma radiation detectors, equipped with ohmic contacts, which allow free electron flow between the contacts and bulk material, will not be sensitive to low hole mobility, hole collection efficiency, or hole trapping. Such fast-operating detectors may be readily integrated into monolithic arrays. The detection mechanism and various material aspects are discussed and compared to those of blocking contact detectors. Some suggestions for detector realization are presented. (orig.)

  16. Management and treatment of contact lens-related Pseudomonas keratitis

    Directory of Open Access Journals (Sweden)

    Willcox MD

    2012-06-01

    Full Text Available Mark DP WillcoxSchool of Optometry and Vision Science, University of New South Wales, Sydney, AustraliaAbstract: Pubmed and Medline were searched for articles referring to Pseudomonas keratitis between the years 2007 and 2012 to obtain an overview of the current state of this disease. Keyword searches used the terms "Pseudomonas" + "Keratitis" limit to "2007–2012", and ["Ulcerative" or "Microbial"] + "Keratitis" + "Contact lenses" limit to "2007–2012". These articles were then reviewed for information on the percentage of microbial keratitis cases associated with contact lens wear, the frequency of Pseudomonas sp. as a causative agent of microbial keratitis around the world, the most common therapies to treat Pseudomonas keratitis, and the sensitivity of isolates of Pseudomonas to commonly prescribed antibiotics. The percentage of microbial keratitis associated with contact lens wear ranged from 0% in a study from Nepal to 54.5% from Japan. These differences may be due in part to different frequencies of contact lens wear. The frequency of Pseudomonas sp. as a causative agent of keratitis ranged from 1% in Japan to over 50% in studies from India, Malaysia, and Thailand. The most commonly reported agents used to treat Pseudomonas keratitis were either aminoglycoside (usually gentamicin fortified with a cephalosporin, or monotherapy with a fluoroquinolone (usually ciprofloxacin. In most geographical areas, most strains of Pseudomonas sp. (≥95% were sensitive to ciprofloxacin, but reports from India, Nigeria, and Thailand reported sensitivity to this antibiotic and similar fluoroquinolones of between 76% and 90%.Keywords: Pseudomonas, keratitis, contact lens

  17. Cobalt sensitization and dermatitis

    DEFF Research Database (Denmark)

    Thyssen, Jacob P

    2012-01-01

    : This clinical review article presents clinical and scientific data on cobalt sensitization and dermatitis. It is concluded that cobalt despite being a strong sensitizer and a prevalent contact allergen to come up on patch testing should be regarded as a very complex metal to test with. Exposure...

  18. Contact allergy to oak moss

    DEFF Research Database (Denmark)

    Bernard, Guillaume; Gimenéz-Arnau, Elena; Rastogi, Suresh Chandra

    2003-01-01

    In addition to pure synthetic fragrance materials several natural extracts are still in use in the perfume industry. Among them oak moss absolute, prepared from the lichen Evernia prunastri (L.) Arch., is considered a major contact sensitizer and is therefore included in the fragrance mix used...... for diagnosing perfume allergy. The process of preparing oak moss absolute has changed during recent years and, even though several potential sensitizers have been identified from former benzene extracts, its present constituents and their allergenic status are not clear. In the study reported here, we applied...

  19. Contact allergy to toothpaste flavors

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner

    1978-01-01

    Toothpaste flavors are fragrance mixtures. Oil of peppermint and spearmint, carvone and anethole are ingredients with a low sensitizing potential, but they are used in almost every brand of toothpaste and caused seven cases of contact allergy in a 6-year period at Gentofte Hospital. Toothpaste...... reactions are rare due to several reasons; local factors in the mouth, the low sensitizing potential of the flavors generally used, and the lack of recognition. It is emphasized that the toothpaste battery for patch testing has to be relevant and changed according to the consumers' and manufacturers' taste...

  20. Personal Chemical Exposure informatics

    Science.gov (United States)

    Chemical Exposure science is the study of human contact with chemicals (from manufacturing facilities, everyday products, waste) occurring in their environments and advances knowledge of the mechanisms and dynamics of events that cause or prevent adverse health outcomes. (adapted...

  1. Contact dermatitis due to xanthium strumarium

    Directory of Open Access Journals (Sweden)

    J S Pasricha

    1990-01-01

    Full Text Available A 50-year-old mining engineer at Dhanbad was having air bome contact Dermatitis suspected to be caused by Xanthium strumarium. Patch tests with a 15% aqueous extract of air dried leaves showed a severe positive reaction, but the patient also had positive patch tests with Parthenium hysterphorus and a few other weeds and trees known to cause air-borne contact dermatitis. The titre of contact hypersensitivity with the extract of Xanthium struma′rium was more than 1:100,000 and for Parthenium hysterophrous it was 1:10 indicating a high degree of hypersensitivity to Xanthium strumarium. Further tests in 14 other patients revealed a high prevalence of cross sensitivity between these two plants both of which belong to the compositae family.

  2. Precision contact level gauge

    International Nuclear Information System (INIS)

    Krejci, M.; Pilat, M.; Stulik, P.

    1977-01-01

    Equipment was developed measuring the heavy water level in the TR-0 reactor core within an accuracy of several hundredths of a millimeter in a range of around 3.5 m and at a temperature of up to 90 degC. The equipment uses a vibrating needle contact as a high sensitivity level gauge and a servomechanical system with a motion screw carrying the gauge for monitoring and measuring the level in the desired range. The advantage of the unique level gauge consists in that that the transducer converts the measured level position to an electric signal, ie., pulse width, with high sensitivity and without hysteresis. (Kr)

  3. DESIGN OF THE CONTACT POTENTIALS DIFFERENCE PROBES

    Directory of Open Access Journals (Sweden)

    K. U. Pantsialeyeu

    2016-01-01

    Full Text Available The contact potential difference probes distinguished by great variety and produced mostly in the laboratory for specific experimental applications. As a rule, they consist of commercially available instrumentation, and have a number of disadvantages: large dimensions, complexity and high cost, small sensitivity, operating speed, noiseproof, etc. The purpose of this paper is to describe the basic approaches to design of the small dimension, complete contact potential difference probes, providing high sensitivity, operating speed, and noise immunity. In this paper the contact potential difference probe, which is a electrometer with dynamic capacitor plate at about 0.1–5 mm2 . These probes are could be used in scanning systems, such as a Scanning Kelvin Probe, as well as for controlling system of manufacturing processes, e.g. under friction. The design of such contact potential difference probes conducted using modern electronic components, unique circuitry and design solutions described in detail at paper. The electromechanical modulator applied for mechanical vibrations of the reference sample. To provide a high amplitude and phase stability the upgraded generator with Wien bridge was used instead traditional oscillation sensor. The preamplifier made on the base of modern operational amplifiers with femtoampere current input. The power of the preamplifier designed with «floating ground». It allows keeping the relation constant potential to the probe components when changing over a wide range the compensation voltage. The phase detector-integrator based on the electronic antiphase switches with the modulation frequency of the contact potential difference and the integrator. Fullwave phase detection would greatly increase the sensitivity of the probe. In addition, the application of the phase detection allows suppressing noise and crosstalk at frequencies different from the modulation frequency. The preamplifier and the reference sample

  4. Broad spectrum antibiotic enrofloxacin modulates contact sensitivity through gut microbiota in a murine model.

    Science.gov (United States)

    Strzępa, Anna; Majewska-Szczepanik, Monika; Lobo, Francis M; Wen, Li; Szczepanik, Marian

    2017-07-01

    Medical advances in the field of infection therapy have led to an increasing use of antibiotics, which, apart from eliminating pathogens, also partially eliminate naturally existing commensal bacteria. It has become increasingly clear that less exposure to microbiota early in life may contribute to the observed rise in "immune-mediated" diseases, including autoimmunity and allergy. We sought to test whether the change of gut microbiota with the broad spectrum antibiotic enrofloxacin will modulate contact sensitivity (CS) in mice. Natural gut microbiota were modified by oral treatment with enrofloxacin prior to sensitization with trinitrophenyl chloride followed by CS testing. Finally, adoptive cell transfers were performed to characterize the regulatory cells that are induced by microbiota modification. Oral treatment with enrofloxacin suppresses CS and production of anti-trinitrophenyl chloride IgG1 antibodies. Adoptive transfer experiments show that antibiotic administration favors induction of regulatory cells that suppress CS. Flow cytometry and adoptive transfer of purified cells show that antibiotic-induced suppression of CS is mediated by TCR αβ + CD4 + CD25 + FoxP3 + Treg, CD19 + B220 + CD5 + IL-10 + , IL-10 + Tr1, and IL-10 + TCR γδ + cells. Treatment with the antibiotic induces dysbiosis characterized by increased proportion of Clostridium coccoides (cluster XIVa), C coccoides-Eubacterium rectale (cluster XIVab), Bacteroidetes, and Bifidobacterium spp, but decreased segmented filamentous bacteria. Transfer of antibiotic-modified gut microbiota inhibits CS, but this response can be restored through oral transfer of control gut bacteria to antibiotic-treated animals. Oral treatment with a broad spectrum antibiotic modifies gut microbiota composition and promotes anti-inflammatory response, suggesting that manipulation of gut microbiota can be a powerful tool to modulate the course of CS. Copyright © 2017 American Academy of Allergy, Asthma & Immunology

  5. Occupational irritant contact dermatitis due to petroleum naphtha

    OpenAIRE

    Aslı Aytekin; Arzu Karataş Toğral

    2014-01-01

    Irritant contact dermatitis (ICD) is responsible for the vast majority of occupational contact dermatitis and usually seen in professional groups working with wet hand. However, today, with the increasing business lines, employees are exposed to a variety of irritants. Occupational exposure to many chemicals and toxic irritants affect not only the skin, but also the other systems. Therefore, this situation resulting with loss of work and changes in business may become a public health problem....

  6. [Determination of joint contact area using MRI].

    Science.gov (United States)

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-10-20

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo.

  7. Determination of joint contact area using MRI

    International Nuclear Information System (INIS)

    Yoshida, Hidenori; Kobayashi, Koichi; Sakamoto, Makoto; Tanabe, Yuji

    2009-01-01

    Elevated contact stress on the articular joints has been hypothesized to contribute to articular cartilage wear and joint pain. However, given the limitations of using contact stress and areas from human cadaver specimens to estimate articular joint stress, there is need for an in vivo method to obtain such data. Magnetic resonance imaging (MRI) has been shown to be a valid method of quantifying the human joint contact area, indicating the potential for in vivo assessment. The purpose of this study was to describe a method of quantifying the tibiofemoral joint contact area using MRI. The validity of this technique was established in porcine cadaver specimens by comparing the contact area obtained from MRI with the contact area obtained using pressure-sensitive film (PSF). In particular, we assessed the actual condition of contact by using the ratio of signal intensity of MR images of cartilage surfaces. Two fresh porcine cadaver knees were used. A custom loading apparatus was designed to apply a compressive load to the tibiofemoral joint. We measured the contact area by using MRI and PSF methods. When the ratio of signal intensity of the cartilage surface was 0.9, the error of the contact area between the MR image and PSF was about 6%. These results suggest that this MRI method may be a valuable tool in quantifying joint contact area in vivo. (author)

  8. Effect of genes controlling radiation sensitivity on chemically induced mutations in Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Prakash, L.

    1976-01-01

    The effect of 16 different genes (rad) conferring radiation sensitivity on chemically induced reversion in the yeast Saccharomyces cerevisiae was determined. The site of reversion used was a well-defined chain initiation mutant mapping in the structural gene coding for iso-1-cytochrome c. High doses of EMS and HNO 2 resulted in decreased reversion of cyc1-131 in rad6, rad9 and rad15 strains compared to the normal RAD + strains. In addition, rad52 greatly decreased EMS reversion of cyc1-131 but had no effect on HNO 2 -induced reversion; rad18, on the other hand, increased HNO 2 -induced reversion but did not alter EMS-induced reversion. When NQO was used as the mutagen, every rad gene tested, except for rad18, had an effect on reversion; rad6, rad9, rad15, rad17, rad18, rad22, rev1, rev2, and rev3 lowered NQO reversion while rad1, rad2, rad3, rad4, rad10, rad12, and rad16 increased it compared to the RAD + strain. The effect of rad genes on chemical mutagenesis is discussed in terms of their effect on uv mutagenesis. It is concluded that although the nature of the repair pathways may differ for uv- and chemically-induced mutations in yeast, a functional repair system is required for the induction of mutation by the chemical agents NQO, EMS, and HNO 2

  9. EAACI Position Paper for practical patch testing in Allergic Contact Dermatitis in children

    DEFF Research Database (Denmark)

    de Waard-van der Spek, Flora B; Darsow, Ulf; Mortz, Charlotte G

    2015-01-01

    Allergic Contact Dermatitis (ACD) in children appears to be on the increase, and contact sensitization may already begin in infancy. The diagnosis of contact dermatitis requires a careful evaluation of a patient's clinical history, physical examination and skin testing. Patch testing is the gold...

  10. Association between cancer and contact allergy: a linkage study

    DEFF Research Database (Denmark)

    Engkilde, Kaare; Thyssen, Jacob P; Menné, Torkil

    2011-01-01

    by logistic regression analysis. Results An inverse association between contact allergy and non-melanoma skin- and breast cancer, respectively, was identified in both sexes, and an inverse trend for brain cancer was found in women with contact allergy. Additionally, a positive association between contact...... allergy and bladder cancer was found. Conclusion The inverse associations support the immunosurveillance hypothesis (ie, individuals with an allergy are less likely to get cancer due to a triggered immune system), while the positive association with bladder cancer could be due to accumulations of chemical...

  11. Occupational irritant contact folliculitis associated with triphenyl tin fluoride (TPTF) exposure

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Petri, M

    1982-01-01

    Triphenyl tin fluoride (TPTF) is a bioactive organo-tin compound used in concentrations 2-12% as anti-foulants in boat paints. The chemical is moderately toxic to the skin. An occupational irritant contact folliculitis from TPTF in a marine paint plant worker is described. Contact allergy...

  12. Physico-chemical mechanism for the vapors sensitivity of photoluminescent InP quantum dots

    Science.gov (United States)

    Prosposito, P.; De Angelis, R.; De Matteis, F.; Hatami, F.; Masselink, W. T.; Zhang, H.; Casalboni, M.

    2016-03-01

    InP/InGaP surface quantum dots are interesting materials for optical chemical sensors since they present an intense emission at room temperature, whose intensity changes rapidly and reversibly depending on the composition of the environmental atmosphere. We present here their emission properties by time resolved photoluminescence spectroscopy investigation and we discuss the physico-chemical mechanism behind their sensitivity to the surrounding atmosphere. Photoluminescence transients in inert atmosphere (N2) and in solvent vapours of methanol, clorophorm, acetone and water were measured. The presence of vapors of clorophorm, acetone and water showed a very weak effect on the transient times, while an increase of up to 15% of the decay time was observed for methanol vapour exposure. On the basis of the vapor molecule nature (polarity, proticity, steric hindrance, etc.) and of the interaction of the vapor molecules with the quantum dots surface a sensing mechanism involving quantum dots non-radiative surface states is proposed.

  13. Physico-chemical mechanism for the vapors sensitivity of photoluminescent InP quantum dots

    International Nuclear Information System (INIS)

    Prosposito, P.; De Angelis, R.; De Matteis, F.; Casalboni, M.; Hatami, F.; Masselink, W.T.; Zhang, H.

    2016-01-01

    InP/InGaP surface quantum dots are interesting materials for optical chemical sensors since they present an intense emission at room temperature, whose intensity changes rapidly and reversibly depending on the composition of the environmental atmosphere. We present here their emission properties by time resolved photoluminescence spectroscopy investigation and we discuss the physico-chemical mechanism behind their sensitivity to the surrounding atmosphere. Photoluminescence transients in inert atmosphere (N 2 ) and in solvent vapours of methanol, chloroform, acetone and water were measured. The presence of vapors of chloroform, acetone and water showed a very weak effect on the transient times, while an increase of up to 15% of the decay time was observed for methanol vapour exposure. On the basis of the vapor molecule nature (polarity, proticity, steric hindrance, etc.) and of the interaction of the vapor molecules with the quantum dots surface a sensing mechanism involving quantum dots non-radiative surface states is proposed. (paper)

  14. Contacts in the Office of Pesticide Programs, Registration Division

    Science.gov (United States)

    The Registration Division (RD) is responsible product registrations, amendments, registrations, tolerances, experimental use permits, and emergency exemptions for conventional chemical pesticides. Find contacts in this division.

  15. [Sensitization to Lyral].

    Science.gov (United States)

    Heras, F; Díaz-Recuero, J L; Cabello, M J; Conde-Salazar, L

    2006-01-01

    Lyral is a fragrance that is present in many cosmetic products. It has turned into an emergent allergen during the last years. In studies carried out in other European countries, the prevalence of sensitization to Lyral has been found to be 1.9-2.7 %, but it is unknown the prevalence in Spain, as well as the need to include it or not in the standard series of the Spanish Group of Contact Dermatitis (GEIDC). We have patch-tested to Lyral all patients with suspicion of contact dermatitis of any origin who attended our Service between April and May-2005. From a total of 170 patients included in our study, 2 of them had a sensitization to Lyral (1.2 %). One of these two patients had an axillae contact dermatitis caused by a deodorant containing Lyral. The other patient was a masseur-woman with a contact dermatitis on both hands, with periods of dissemination to upper extremities and trunk, and who used several cosmetics products for private reasons and during her job. Although the sample of this study is quite small, we think that the results allow to suspect that Lyral is one of the main allergens, or even the most important, in causing allergic contact dermatitis to fragrances in our environment. Therefore, we believe that we must raise the inclusion of Lyral in the standard series of GEIDC, either as independent allergen, or including it in a new mixture of fragrances.

  16. Chemical cues from fish heighten visual sensitivity in larval crabs through changes in photoreceptor structure and function.

    Science.gov (United States)

    Charpentier, Corie L; Cohen, Jonathan H

    2015-11-01

    Several predator avoidance strategies in zooplankton rely on the use of light to control vertical position in the water column. Although light is the primary cue for such photobehavior, predator chemical cues or kairomones increase swimming responses to light. We currently lack a mechanistic understanding for how zooplankton integrate visual and chemical cues to mediate phenotypic plasticity in defensive photobehavior. In marine systems, kairomones are thought to be amino sugar degradation products of fish body mucus. Here, we demonstrate that increasing concentrations of fish kairomones heightened sensitivity of light-mediated swimming behavior for two larval crab species (Rhithropanopeus harrisii and Hemigrapsus sanguineus). Consistent with these behavioral results, we report increased visual sensitivity at the retinal level in larval crab eyes directly following acute (1-3 h) kairomone exposure, as evidenced electrophysiologically from V-log I curves and morphologically from wider, shorter rhabdoms. The observed increases in visual sensitivity do not correspond with a decline in temporal resolution, because latency in electrophysiological responses actually increased after kairomone exposure. Collectively, these data suggest that phenotypic plasticity in larval crab photobehavior is achieved, at least in part, through rapid changes in photoreceptor structure and function. © 2015. Published by The Company of Biologists Ltd.

  17. Clinical vocabulary as a boundary object in multidisciplinary care management of multiple chemical sensitivity, a complex and chronic condition.

    Science.gov (United States)

    Sampalli, Tara; Shepherd, Michael; Duffy, Jack

    2011-04-14

    Research has shown that accurate and timely communication between multidisciplinary clinicians involved in the care of complex and chronic health conditions is often challenging. The domain knowledge for these conditions is heterogeneous, with poorly categorized, unstructured, and inconsistent clinical vocabulary. The potential of boundary object as a technique to bridge communication gaps is explored in this study. A standardized and controlled clinical vocabulary was developed as a boundary object in the domain of a complex and chronic health condition, namely, multiple chemical sensitivity, to improve communication among multidisciplinary clinicians. A convenience sample of 100 patients with a diagnosis of multiple chemical sensitivity, nine multidisciplinary clinicians involved in the care of patients with multiple chemical sensitivity, and 36 clinicians in the community participated in the study. Eighty-two percent of the multidisciplinary and inconsistent vocabulary was standardized using the Systematized Nomenclature of Medicine - Clinical Terms (SNOMED(®) CT as a reference terminology. Over 80% of the multidisciplinary clinicians agreed on the overall usefulness of having a controlled vocabulary as a boundary object. Over 65% of clinicians in the community agreed on the overall usefulness of the vocabulary. The results from this study are promising and will be further evaluated in the domain of another complex chronic condition, ie, chronic pain. The study was conducted as a preliminary analysis for developing a boundary object in a heterogeneous domain of knowledge.

  18. Acute sensitivity of freshwater mollusks and commonly tested invertebrates to select chemicals with different toxic models of action

    Science.gov (United States)

    Previous studies indicate that freshwater mollusks are more sensitive than commonly tested organisms to some chemicals, such as copper and ammonia. Nevertheless, mollusks are generally under-represented in toxicity databases. Studies are needed to generate data with which to comp...

  19. Hair-dye induced erythema multiforme like allergic contact dermatitis

    Directory of Open Access Journals (Sweden)

    Mrinal Gupta

    2017-04-01

    Full Text Available Erythema multiforme (EM is an acute, self limited skin disease characterized by the sudden eruption of symmetrical lesions in typical targetoid fashion usually confined to face and extremities. The most commonly implicated factors include infections like herpes simplex, mycoplasma, drugs like antibiotics and anticonvulsants and vaccinations. Contact dermatitis induced EM is a rarely reported entity. Herein we present a case of a 40 year old female who presented with EM due to contact sensitivity to p-Paraphenylenediamine (PPD, a common coloring agent in hair-dyes and a potent sensitizer. Till date, there have been only a few case reports of PPD induced EM.

  20. Sensitivity of transatlantic dust transport to chemical aging and related atmospheric processes

    KAUST Repository

    Abdelkader, Mohamed

    2017-03-20

    We present a sensitivity study on transatlantic dust transport, a process which has many implications for the atmosphere, the ocean and the climate. We investigate the impact of key processes that control the dust outflow, i.e., the emission flux, convection schemes and the chemical aging of mineral dust, by using the EMAC model following Abdelkader et al. (2015). To characterize the dust outflow over the Atlantic Ocean, we distinguish two geographic zones: (i) dust interactions within the Intertropical Convergence Zone (ITCZ), or the dust–ITCZ interaction zone (DIZ), and (ii) the adjacent dust transport over the Atlantic Ocean (DTA) zone. In the latter zone, the dust loading shows a steep and linear gradient westward over the Atlantic Ocean since particle sedimentation is the dominant removal process, whereas in the DIZ zone aerosol–cloud interactions, wet deposition and scavenging processes determine the extent of the dust outflow. Generally, the EMAC simulated dust compares well with CALIPSO observations; however, our reference model configuration tends to overestimate the dust extinction at a lower elevation and underestimates it at a higher elevation. The aerosol optical depth (AOD) over the Caribbean responds to the dust emission flux only when the emitted dust mass is significantly increased over the source region in Africa by a factor of 10. These findings point to the dominant role of dust removal (especially wet deposition) in transatlantic dust transport. Experiments with different convection schemes have indeed revealed that the transatlantic dust transport is more sensitive to the convection scheme than to the dust emission flux parameterization. To study the impact of dust chemical aging, we focus on a major dust outflow in July 2009. We use the calcium cation as a proxy for the overall chemical reactive dust fraction and consider the uptake of major inorganic acids (i.e., H2SO4, HNO3 and HCl) and their anions, i.e., sulfate (SO42−), bisulfate

  1. The Unique Molecular Signatures of Contact Dermatitis and Implications for Treatment.

    Science.gov (United States)

    Leonard, Alexandra; Guttman-Yassky, Emma

    2018-05-12

    Irritant contact dermatitis (ICD) and allergic contact dermatitis (ACD) are common skin disorders that are characterized by inflammation, oozing, crusting, and pruritus. Atopic dermatitis (AD) is an inflammatory skin disease characterized by immune and barrier abnormalities and is additionally a risk factor for acquiring ICD and ACD. New work on allergic sensitization to common allergens (e.g., nickel and fragrance) in human skin has shown that different allergens have distinct molecular fingerprinting. For example, nickel promotes strong Th1/Th17 polarization, whereas fragrance allergy causes Th2/Th22 skewing, which is similar to the phenotype of AD. While ACD has previously been considered to be constant across all allergens, largely based on mouse models involving strong sensitizers, these new data suggest that ACD differs mechanistically according to allergen. Further, ACD in the setting of concurrent AD shows a different and attenuated phenotype as compared to healthy individuals with ACD, which influences the way AD patients respond to vaccination and other treatment modalities. As in contact sensitization, skin challenged by food patch testing shows that common food allergens (e.g., peanut and barley) also cause distinct immune polarizations in the skin. Additionally, house dust mite reactions in human skin have been profiled to show unique Th2, Th9, and Th17/22 activation as compared to controls, which are similar to the phenotype of psoriasis and contact responses to nickel. Given this information, ACD patients should be treated based on their unique allergen polarity. Refined understanding of the molecular behavior of contact dermatitis and related diseases translates to improved methods of inducing tolerance in sensitized allergic patients, such as with targeted drug therapy and epicutaneous immunotherapy.

  2. Self-regulating chemo-mechano-chemical systems

    Science.gov (United States)

    Aizenberg, Joanna; He, Ximin; Aizenberg, Michael

    2017-05-16

    A chemo-mechano-chemical (C.sub.1-M-C.sub.2) system includes a base supporting an actuatable structure, said structure comprising a functionalized portion and being embedded in an environmentally responsive gel capable of volume change in response to an environmental stimulus; a first fluid layer disposed over the base and in contact with the actuatable structure, said first fluid layer comprising the environmentally responsive gel; and a second fluid layer in contact with the actuatable structure, wherein the layers are positioned such that the functionalized portion is in contact with the second layer in a first relaxed state and in contact with the first layer in a second actuated state and wherein the functionalized portion interacts with at least one of the layers to provide a chemical or physical response.

  3. Allergic contact dermatitis to fragrance: a review.

    Science.gov (United States)

    Scheinman, P L

    1996-06-01

    Allergy to fragrance is the most common cause of cosmetic contact dermatitis and therefore constitutes a significant clinical problem. The widespread use of fragranced materials in skin care and household products is probably the most important reason for the high incidence of fragrance sensitization. This report will summarize the history of fragrance, review how to detect and evaluate fragrance allergy, discuss the problems inherent in patch testing with the fragrance mix and its constituents, describe systemic contact dermatitis from ingestion of certain flavors, and give suggestions for fragrance-sensitive patients. The use of fragrance mix in patch testing has been invaluable in detecting fragrance allergy. Continued investigation into positive patch test responses to fragrance in scented products is essential in helping to identify new fragrance allergens. Additionally, more cooperation is necessary between industry and dermatologists in assisting patients to avoid proven allergens.

  4. Tungsten silicide contacts to polycrystalline silicon and silicon-germanium alloys

    International Nuclear Information System (INIS)

    Srinivasan, G.; Bain, M.F.; Bhattacharyya, S.; Baine, P.; Armstrong, B.M.; Gamble, H.S.; McNeill, D.W.

    2004-01-01

    Silicon-germanium alloy layers will be employed in the source-drain engineering of future MOS transistors. The use of this technology offers advantages in reducing series resistance and decreasing junction depth resulting in reduction in punch-through and SCE problems. The contact resistance of metal or metal silicides to the raised source-drain material is a serious issue at sub-micron dimensions and must be minimised. In this work, tungsten silicide produced by chemical vapour deposition has been investigated as a contact metallization scheme to both boron and phosphorus doped polycrystalline Si 1- x Ge x , with 0 ≤x ≤ 0.3. Cross bridge Kelvin resistor (CKBR) structures were fabricated incorporating CVD WSi 2 and polycrystalline SiGe. Tungsten silicide contacts to control polysilicon CKBR structures have been shown to be of high quality with specific contact resistance ρ c values 3 x 10 -7 ohm cm 2 and 6 x 10 -7 ohm cm 2 obtained to boron and phosphorus implanted samples respectively. The SiGe CKBR structures show that the inclusion of Ge yields a reduction in ρ c for both dopant types. The boron doped SiGe exhibits a reduction in ρ c from 3 x 10 -7 to 5 x 10 -8 ohm cm 2 as Ge fraction is increased from 0 to 0.3. The reduction in ρ c has been shown to be due to (i) the lowering of the tungsten silicide Schottky barrier height to p-type SiGe resulting from the energy band gap reduction, and (ii) increased activation of the implanted boron with increased Ge fraction. The phosphorus implanted samples show less sensitivity of ρ c to Ge fraction with a lowest value in this work of 3 x 10 -7 ohm cm 2 for a Ge fraction of 0.3. The reduction in specific contact resistance to the phosphorus implanted samples has been shown to be due to increased dopant activation alone

  5. A comparison of chemical shift sensitivity of trifluoromethyl tags: optimizing resolution in {sup 19}F NMR studies of proteins

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Libin; Larda, Sacha Thierry; Frank Li, Yi Feng [University of Toronto, UTM, Department of Chemistry (Canada); Manglik, Aashish [Stanford University School of Medicine, Department of Molecular and Cellular Physiology (United States); Prosser, R. Scott, E-mail: scott.prosser@utoronto.ca [University of Toronto, UTM, Department of Chemistry (Canada)

    2015-05-15

    The elucidation of distinct protein conformers or states by fluorine ({sup 19}F) NMR requires fluorinated moieties whose chemical shifts are most sensitive to subtle changes in the local dielectric and magnetic shielding environment. In this study we evaluate the effective chemical shift dispersion of a number of thiol-reactive trifluoromethyl probes [i.e. 2-bromo-N-(4-(trifluoromethyl)phenyl)acetamide (BTFMA), N-(4-bromo-3-(trifluoromethyl)phenyl)acetamide (3-BTFMA), 3-bromo-1,1,1-trifluoropropan-2-ol (BTFP), 1-bromo-3,3,4,4,4-pentafluorobutan-2-one (BPFB), 3-bromo-1,1,1-trifluoropropan-2-one (BTFA), and 2,2,2-trifluoroethyl-1-thiol (TFET)] under conditions of varying polarity. In considering the sensitivity of the {sup 19}F NMR chemical shift to the local environment, a series of methanol/water mixtures were prepared, ranging from relatively non-polar (MeOH:H{sub 2}O = 4) to polar (MeOH:H{sub 2}O = 0.25). {sup 19}F NMR spectra of the tripeptide, glutathione ((2S)-2-amino-4-{[(1R)-1-[(carboxymethyl)carbamoyl] -2-sulfanylethyl]carbamoyl}butanoic acid), conjugated to each of the above trifluoromethyl probes, revealed that the BTFMA tag exhibited a significantly greater range of chemical shift as a function of solvent polarity than did either BTFA or TFET. DFT calculations using the B3LYP hybrid functional and the 6-31G(d,p) basis set, confirmed the observed trend in chemical shift dispersion with solvent polarity.

  6. Chemical stability and in chemico reactivity of 24 fragrance ingredients of concern for skin sensitization risk assessment.

    Science.gov (United States)

    Avonto, Cristina; Wang, Mei; Chittiboyina, Amar G; Vukmanovic, Stanislav; Khan, Ikhlas A

    2018-02-01

    Twenty-four pure fragrance ingredients have been identified as potential concern for skin sensitization. Several of these compounds are chemically unstable and convert into reactive species upon exposure to air or light. In the present work, a systematic investigation of the correlation between chemical stability and reactivity has been undertaken. The compounds were subjected to forced photodegradation for three months and the chemical changes were studied with GC-MS. At the end of the stability study, two-thirds of the samples were found to be unstable. The generation of chemically reactive species was investigated using the in chemico HTS-DCYA assay. Eleven and fourteen compounds were chemically reactive before and after three months, respectively. A significant increase in reactivity upon degradation was found for isoeugenol, linalool, limonene, lyral, citronellol and geraniol; in the same conditions, the reactivity of hydroxycitronellal decreased. The non-reactive compounds α-isomethyl ionone, benzyl alcohol, amyl cinnamal and farnesol became reactive after photo-oxidative degradation. Overall, forced degradation resulted in four non-reactive fragrance compounds to display in chemico thiol reactivity, while ten out of 24 compounds remained inactive. Chemical degradation does not necessarily occur with generation of reactive species. Non-chemical activation may be involved for the 10 stable unreactive compounds. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Activation of non-sensitizing or low-sensitizing fragrance substances into potent sensitizers - prehaptens and prohaptens

    DEFF Research Database (Denmark)

    Karlberg, Ann-Therese; Börje, Anna; Duus Johansen, Jeanne

    2013-01-01

    the risk of sensitization. In the present review a series of fragrance substances with well documented abiotic and/or biotic activation are given as indicative and illustrative examples of the general problem. Commonly used fragrance substances, also found in essential oils, autoxidize on contact with air...

  8. Mechanoluminescent Contact Type Sensor

    Directory of Open Access Journals (Sweden)

    A. K. Yefremov

    2017-01-01

    Full Text Available Mechanoluminescent sensing elements convert mechanical stress into optical radiation. Advantages of such sensors are the ability to generate an optical signal, solid-state, simple structure, and resistance to electromagnetic interference. Mechanoluminescent sensor implementations can possess the concentrated and distributed sensitivity, thereby allowing us to detect the field of mechanical stresses distributed across the area and in volume. Most modern semiconductor photo-detectors can detect mechanoluminescent radiation, so there are no difficulties to provide its detection when designing the mechanoluminescent sensing devices. Mechanoluminescent substances have especial sensitivity to shock loads, and this effect can be used to create a fuse the structure of which includes a target contact type sensor with a photosensitive actuator. The paper briefly describes the theoretical basics of mechanoluminiscence: a light signal emerges from the interaction of crystalline phosphor luminescence centers with electrically charged dislocations, moving due to the deformation of the crystal. A mathematical model of the mechanoluminescent conversion is represented as a functional interaction between parameters of the mechanical shock excitation and the sensor light emission. Examples of computing the optical mechanoluminescent output signal depending on the duration and peak level of impulse load are given. It is shown that the luminous flux, generated by mechanoluminescent sensing element when there is an ammunition-target collision causes the current emerging in photo-detector (photodiode that is sufficient for a typical actuator of the fuse train to operate. The potential possibility to create a contact target type sensor based on the light-sensitive mechanoluminescent sensor was proved by the calculation and simulation results.

  9. Methylisothiazolinone contact allergy - A review

    DEFF Research Database (Denmark)

    Lundov, M D; Krongaard, Teddy; L Menné, T

    2011-01-01

    In the early 2000s the preservative methylisothiazolinone (MI) was released as an individual preservative for industrial products and in 2005 permitted for use in cosmetic products. Up till then MI had only been used in combination with methylcholoroisthiazolinone (MCI). MCI/MI is one of the most...... frequent causes of preservative contact allergy and early studies showed that both MI and MCI are sensitizers. The prevalence of MI contact allergy is already around 1·5% and sources of exposure are associated with occupation, cosmetic products or household products. Use of MI in industrial products...... is not restricted and cases of occupational contact allergy to MI e.g. in painters are reported. The frequency of use of MI in cosmetics is low, around 1%, while up to 16·5% of household products were preserved with MI. We found 19 (1·5%) out of 1272 cosmetic products labelled with MI, primarily rinse-off products...

  10. Methylisothiazolinone contact allergy: a review

    DEFF Research Database (Denmark)

    Lundov, M D; Krongaard, T; Menné, T L

    2011-01-01

    In the early 2000s the preservative methylisothiazolinone (MI) was released as an individual preservative for industrial products and in 2005 permitted for use in cosmetic products. Up till then MI had only been used in combination with methylcholoroisthiazolinone (MCI). MCI/MI is one of the most...... frequent causes of preservative contact allergy and early studies showed that both MI and MCI are sensitizers. The prevalence of MI contact allergy is already around 1·5% and sources of exposure are associated with occupation, cosmetic products or household products. Use of MI in industrial products...... is not restricted and cases of occupational contact allergy to MI e.g. in painters are reported. The frequency of use of MI in cosmetics is low, around 1%, while up to 16·5% of household products were preserved with MI. We found 19 (1·5%) out of 1272 cosmetic products labelled with MI, primarily rinse-off products...

  11. Lack of the purinergic receptor P2X7 results in resistance to contact hypersensitivity

    Science.gov (United States)

    Weber, Felix C.; Esser, Philipp R.; Müller, Tobias; Ganesan, Jayanthi; Pellegatti, Patrizia; Simon, Markus M.; Zeiser, Robert; Idzko, Marco; Jakob, Thilo

    2010-01-01

    Sensitization to contact allergens requires activation of the innate immune system by endogenous danger signals. However, the mechanisms through which contact allergens activate innate signaling pathways are incompletely understood. In this study, we demonstrate that mice lacking the adenosine triphosphate (ATP) receptor P2X7 are resistant to contact hypersensitivity (CHS). P2X7-deficient dendritic cells fail to induce sensitization to contact allergens and do not release IL-1β in response to lipopolysaccharide (LPS) and ATP. These defects are restored by pretreatment with LPS and alum in an NLRP3- and ASC-dependent manner. Whereas pretreatment of wild-type mice with P2X7 antagonists, the ATP-degrading enzyme apyrase or IL-1 receptor antagonist, prevents CHS, IL-1β injection restores CHS in P2X7-deficient mice. Thus, P2X7 is a crucial receptor for extracellular ATP released in skin in response to contact allergens. The lack of P2X7 triggering prevents IL-1β release, which is an essential step in the sensitization process. Interference with P2X7 signaling may be a promising strategy for the prevention of allergic contact dermatitis. PMID:21059855

  12. Noise sensitivity: symptoms, health status, illness behavior and co-occurring environmental sensitivities.

    NARCIS (Netherlands)

    Baliatsas, C.; Kamp, I. van; Swart, W.; Hooiveld, M.; Yzermans, J.

    2016-01-01

    Epidemiological evidence on the symptomatic profile, health status and illness behavior of people with subjective sensitivity to noise is still scarce. Also, it is unknown to what extent noise sensitivity co-occurs with other environmental sensitivities such as multi-chemical sensitivity and

  13. Extremely sensitive multiple sensing ring PCF sensor for lower indexed chemical detection

    Directory of Open Access Journals (Sweden)

    Veerpal Kaur

    2017-09-01

    Full Text Available In this article, we have designed and analysed a photonic crystal fiber with multiple sensing ring in core for chemical and biochemical sensing applications. In this proposed design, three and four sensing ring describe in core which offers remarkable high sensitivity and spiral cladding pattern confines large fraction of power in core region and thus reduce the overall confinement loss. This novel proposed model exhibits simultaneously ultra high relative sensitivity 95.40%, 93.13% and minimum confinement loss 7.108×10−08, 2.47×10−08dB/km for four and three ring pattern. These sensing rings are filled with different sensing liquid. Multiple sensing rings as compared to multiple air holes are desirable feature from fabrication point of view. This proposed PCF design overcomes some experimental challenge such as PCF probe needs some displacement after filling the sensing liquid. These uniform circular sensing rings around the solid core overcome the losses and support better evanescent field matter interaction for sensing application. Multiple sensing rings as compared to multiple tiny air holes are desirable feature from fabrication point of view.

  14. Safety evaluation of food contact paper and board using chemical tests and in vitro bioassays: role of known and unknown substances.

    Science.gov (United States)

    Honkalampi-Hämäläinen, U; Bradley, E L; Castle, L; Severin, I; Dahbi, L; Dahlman, O; Lhuguenot, J-C; Andersson, M A; Hakulinen, P; Hoornstra, D; Mäki-Paakkanen, J; Salkinoja-Salonen, M; Turco, L; Stammati, A; Zucco, F; Weber, A; von Wright, A

    2010-03-01

    In vitro toxicological tests have been proposed as an approach to complement the chemical safety assessment of food contact materials, particularly those with a complex or unknown chemical composition such as paper and board. Among the concerns raised regarding the applicability of in vitro tests are the effects of interference of the extractables on the outcome of the cytotoxicity and genotoxicity tests applied and the role of known compounds present in chemically complex materials, such as paper and board, either as constituents or contaminants. To answer these questions, a series of experiments were performed to assess the role of natural substances (wood extracts, resin acids), some additives (diisopropylnaphthalene, phthalates, acrylamide, fluorescent whitening agents) and contaminants (2,4-diaminotoluene, benzo[a]pyrene) in the toxicological profile of paper and board. These substances were individually tested or used to spike actual paper and board extracts. The toxic concentrations of diisopropylnaphthalenes and phthalates were compared with those actually detected in paper and board extracts showing conspicuous toxicity. According to the results of the spiking experiments, the extracts did not affect the toxicity of tested chemicals nor was there any significant metabolic interference in the cases where two compounds were used in tests involving xenobiotic metabolism by the target cells. While the identified substances apparently have a role in the cytotoxicity of some of the project samples, their presence does not explain the total toxicological profile of the extracts. In conclusion, in vitro toxicological testing can have a role in the safety assessment of chemically complex materials in detecting potentially harmful activities not predictable by chemical analysis alone.

  15. Contact conductance between graphene and quantum wires

    International Nuclear Information System (INIS)

    Li Haidong; Zheng Yisong

    2009-01-01

    The contact conductance between graphene and two quantum wires which serve as the leads to connect graphene and electron reservoirs is theoretically studied. Our investigation indicates that the contact conductance depends sensitively on the graphene-lead coupling configuration. When each quantum wire couples solely to one carbon atom, the contact conductance vanishes at the Dirac point if the two carbon atoms coupling to the two leads belong to the same sublattice of graphene. We find that such a feature arises from the chirality of the Dirac electron in graphene. Such a chirality associated with conductance zero disappears when a quantum wire couples to multiple carbon atoms. The general result irrelevant to the coupling configuration is that the contact conductance decays rapidly with the increase of the distance between the two leads. In addition, in the weak graphene-lead coupling limit, when the distance between the two leads is much larger than the size of the graphene-lead contact areas and the incident electron energy is close to the Dirac point, the contact conductance is proportional to the square of the product of the two graphene-lead contact areas, and inversely proportional to the square of the distance between the two leads

  16. Contact glow discharge electrolysis: its origin, plasma diagnostics and non-faradaic chemical effects

    International Nuclear Information System (INIS)

    Sen Gupta, Susanta K

    2015-01-01

    Contact glow discharge electrolysis (CGDE) also termed plasma electrolysis is a novel electrolysis where a stable sheath of light emitting plasma develops around an electrode immersed well inside a relatively high-conductivity liquid electrolyte during normal electrolysis (NE) at several hundred volts. The phenomenon may develop in dc-, pulsed dc-, ac- as well as RF-driven electrolyses. The chemical effects of CGDE are remarkably non-faradaic in respect to the nature of the products as well as their yields. The article traces comprehensively the progress made in studies of CGDE in aqueous and non-aqueous solutions since 1844 and reviews the developments in the understanding of its origin, light emission, plasma state and non-faradaic effects leading to the elucidation of detailed mechanism of the origin of CGDE on the basis of the onset of hydrodynamic instabilities in local vaporization of the solvent near the working electrode during NE, and that of highly non-faradaic effects of CGDE based on a model of two reaction zones located within the electrode plasma and at the plasma–liquid interface producing solvent derived radicals at high local concentrations. Keeping in view the recent surge of interest in varied applications of CGDE, the article is appended with highlights of these applications across synthetic chemistry, waste water treatment, electrosurgical devices, nanoparticle fabrications, surface engineering and micro-machining. (topical review)

  17. Contact ion pair formation between hard acids and soft bases in aqueous solutions observed with 2DIR spectroscopy.

    Science.gov (United States)

    Sun, Zheng; Zhang, Wenkai; Ji, Minbiao; Hartsock, Robert; Gaffney, Kelly J

    2013-12-12

    The interaction of charged species in aqueous solution has important implications for chemical, biological, and environmental processes. We have used 2DIR spectroscopy to study the equilibrium dynamics of thiocyanate chemical exchange between free ion (NCS(-)) and contact ion pair configurations (MNCS(+)), where M(2+) = Mg(2+) or Ca(2+). Detailed studies of the influence of anion concentration and anion speciation show that the chemical exchange observed with the 2DIR measurements results from NCS(-) exchanging with other anion species in the first solvation shell surrounding Mg(2+) or Ca(2+). The presence of chemical exchange in the 2DIR spectra provides an indirect, but robust, determinant of contact ion pair formation. We observe preferential contact ion pair formation between soft Lewis base anions and hard Lewis acid cations. This observation cannot be easily reconciled with Pearson's acid-base concept or Collins' Law of Matching Water Affinities. The anions that form contact ion pairs also correspond to the ions with an affinity for water and protein surfaces, so similar physical and chemical properties may control these distinct phenomena.

  18. How sensitizing is chlorocresol?

    DEFF Research Database (Denmark)

    Andersen, Klaus Ejner; Hamann, K

    1984-01-01

    Chlorocresol is a biocide with widespread use in industry and pharmaceutical products. It is an occasional human contact sensitizer. The sensitizing potential of chlorocresol was judged strong using the guinea pig maximization test (GPMT) and doubtful in the less sensitive open epicutaneous test......% in pet. showed 11 reactions among 1462 patients tested, but none were explainable and reproducible during re-tests and provocative use tests, indicating that the GPMT overestimated the sensitization potential. The results from guinea pig allergy tests cannot stand alone but have to be validated by other...

  19. Unexpected Ge-Ge contacts in the two-dimensional Ge{sub 4}Se{sub 3}Te phase and analysis of their chemical cause with the density of energy (DOE) function

    Energy Technology Data Exchange (ETDEWEB)

    Kuepers, Michael; Konze, Philipp M.; Maintz, Stefan; Steinberg, Simon [Institute of Inorganic Chemistry, Chair of Solid-State and Quantum Chemistry, RWTH Aachen University (Germany); Mio, Antonio M.; Cojocaru-Miredin, Oana; Zhu, Min; Wuttig, Matthias [I. Physikalisches Institut, RWTH Aachen University (Germany); Mueller, Merlin; Mayer, Joachim [Gemeinschaftslabor fuer Elektronenmikroskopie, RWTH Aachen University (Germany); Luysberg, Martina [Ernst-Ruska-Center, Forschungszentrum Juelich GmbH (Germany); Dronskowski, Richard [Institute of Inorganic Chemistry, Chair of Solid-State and Quantum Chemistry, RWTH Aachen University (Germany); Juelich-Aachen Research Alliance (JARA-HPC), RWTH Aachen University (Germany)

    2017-08-14

    A hexagonal phase in the ternary Ge-Se-Te system with an approximate composition of GeSe{sub 0.75}Te{sub 0.25} has been known since the 1960s but its structure has remained unknown. We have succeeded in growing single crystals by chemical transport as a prerequisite to solve and refine the Ge{sub 4}Se{sub 3}Te structure. It consists of layers that are held together by van der Waals type weak chalcogenide-chalcogenide interactions but also display unexpected Ge-Ge contacts, as confirmed by electron microscopy analysis. The nature of the electronic structure of Ge{sub 4}Se{sub 3}Te was characterized by chemical bonding analysis, in particular by the newly introduced density of energy (DOE) function. The Ge-Ge bonding interactions serve to hold electrons that would otherwise go into antibonding Ge-Te contacts. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Skin sensitization potency and cross-reactivity of p-phenylenediamine and its derivatives evaluated by non-radioactive murine local lymph node assay and guinea-pig maximization test.

    Science.gov (United States)

    Yamano, Tetsuo; Shimizu, Mitsuru

    2009-04-01

    p-Phenylenediamine (PPD)-related chemicals have been used as antioxidants in rubber products, and many cases of contact dermatitis caused by these chemicals have been reported. The aim of this study was to investigate relative sensitizing potency and cross-reactivity among PPD derivatives. Five PPD derivatives, p-aminodiphenylamine (PADPA), N,N'-diphenyl-p-phenylenediamine (DPPD), N-isopropyl-N'-phenyl-p-phenylenediamine (IPPD), N-(1,3-dimethylbutyl)-N'-phenyl-p-phenylenediamine (DMBPPD), N-(1-methylheptyl)-N'-phenyl-p-phenylenediamine (MHPPD), and the core chemical PPD were evaluated for their sensitizing potency and cross-reactivity using the non-radioactive murine local lymph node assay (LLNA) and the guinea-pig maximization test (GPMT). PPD and all the derivatives were identified as primary sensitizers in both tests. The order of potency in the LLNA was as follows: IPPD and PADPA > PPD > DMBPPD and MHPPD > DPPD. In the GPMT, all six groups of animals sensitized with one of these chemicals cross-reacted to four other derivatives. Specifically, the five groups that have a common basic PADPA structure, that is PADPA, DPPD, IPPD, DMBPPD, and MHPPD, all reacted to each other at almost the same scores, while none of them reacted to PPD. The cross-reactivity profile found in the study was to some extent different from that in previous human data, where distinction between cross-reaction and concomitant primary sensitization is not always clear.

  1. Ultra-low contact resistance in graphene devices at the Dirac point

    Science.gov (United States)

    Anzi, Luca; Mansouri, Aida; Pedrinazzi, Paolo; Guerriero, Erica; Fiocco, Marco; Pesquera, Amaia; Centeno, Alba; Zurutuza, Amaia; Behnam, Ashkan; Carrion, Enrique A.; Pop, Eric; Sordan, Roman

    2018-04-01

    Contact resistance is one of the main factors limiting performance of short-channel graphene field-effect transistors (GFETs), preventing their use in low-voltage applications. Here we investigated the contact resistance between graphene grown by chemical vapor deposition (CVD) and different metals, and found that etching holes in graphene below the contacts consistently reduced the contact resistance, down to 23 Ω \\cdot μ m with Au contacts. This low contact resistance was obtained at the Dirac point of graphene, in contrast to previous studies where the lowest contact resistance was obtained at the highest carrier density in graphene (here 200 Ω \\cdot μ m was obtained under such conditions). The ‘holey’ Au contacts were implemented in GFETs which exhibited an average transconductance of 940 S m-1 at a drain bias of only 0.8 V and gate length of 500 nm, which out-perform GFETs with conventional Au contacts.

  2. SKIN SENSITIZATION AND ALLERGIC CONTACT DERMATITIS (BASIC COURSE): THE GLOBAL REGULATORY ENVIRONMENT - CONTINUING EDUCATION COURSE; 1 OF 4 SPEAKERS FOR AN SOT BASIC COURSE

    Science.gov (United States)

    New regulations have emerged in recent years giving guidance on how best to conduct skin sensitization testing on new chemical entities. For example, recently The Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) in the U.S. and the European Ce...

  3. Capacitive chemical sensor

    Science.gov (United States)

    Manginell, Ronald P; Moorman, Matthew W; Wheeler, David R

    2014-05-27

    A microfabricated capacitive chemical sensor can be used as an autonomous chemical sensor or as an analyte-sensitive chemical preconcentrator in a larger microanalytical system. The capacitive chemical sensor detects changes in sensing film dielectric properties, such as the dielectric constant, conductivity, or dimensionality. These changes result from the interaction of a target analyte with the sensing film. This capability provides a low-power, self-heating chemical sensor suitable for remote and unattended sensing applications. The capacitive chemical sensor also enables a smart, analyte-sensitive chemical preconcentrator. After sorption of the sample by the sensing film, the film can be rapidly heated to release the sample for further analysis. Therefore, the capacitive chemical sensor can optimize the sample collection time prior to release to enable the rapid and accurate analysis of analytes by a microanalytical system.

  4. Role of Metal Contacts in High-Performance Phototransistors Based on WSe 2 Monolayers

    KAUST Repository

    Zhang, Wenjing; Chiu, Ming-Hui; Chen, Chang-Hsiao; Chen, Wei; Li, Lain-Jong; Wee, Andrew Thye Shen

    2014-01-01

    Phototransistors based on monolayer transition metal dichalcogenides (TMD) have high photosensitivity due to their direct band gap transition. However, there is a lack of understanding of the effect of metal contacts on the performance of atomically thin TMD phototransistors. Here, we fabricate phototransistors based on large-area chemical vapor deposition (CVD) tungsten diselenide (WSe2) monolayers contacted with the metals of different work function values. We found that the low Schottky-contact WSe2 phototransistors exhibit a very high photo gain (105) and specific detectivity (1014Jones), values higher than commercial Si- and InGaAs-based photodetectors; however, the response speed is longer than 5 s in ambient air. In contrast, the high Schottky-contact phototransistors display a fast response time shorter than 23 ms, but the photo gain and specific detectivity decrease by several orders of magnitude. Moreover, the fast response speed of the high Schottky-contact devices is maintained for a few months in ambient air. This study demonstrates that the contact plays an important role in TMD phototransistors, and barrier height tuning is critical for optimizing the photoresponse and photoresponsivity. © 2014 American Chemical Society.

  5. Role of Metal Contacts in High-Performance Phototransistors Based on WSe 2 Monolayers

    KAUST Repository

    Zhang, Wenjing

    2014-08-26

    Phototransistors based on monolayer transition metal dichalcogenides (TMD) have high photosensitivity due to their direct band gap transition. However, there is a lack of understanding of the effect of metal contacts on the performance of atomically thin TMD phototransistors. Here, we fabricate phototransistors based on large-area chemical vapor deposition (CVD) tungsten diselenide (WSe2) monolayers contacted with the metals of different work function values. We found that the low Schottky-contact WSe2 phototransistors exhibit a very high photo gain (105) and specific detectivity (1014Jones), values higher than commercial Si- and InGaAs-based photodetectors; however, the response speed is longer than 5 s in ambient air. In contrast, the high Schottky-contact phototransistors display a fast response time shorter than 23 ms, but the photo gain and specific detectivity decrease by several orders of magnitude. Moreover, the fast response speed of the high Schottky-contact devices is maintained for a few months in ambient air. This study demonstrates that the contact plays an important role in TMD phototransistors, and barrier height tuning is critical for optimizing the photoresponse and photoresponsivity. © 2014 American Chemical Society.

  6. Filamentary superhydrophobic Teflon surfaces: Moderate apparent contact angle but superior air-retaining properties.

    Science.gov (United States)

    Di Mundo, Rosa; Bottiglione, Francesco; Palumbo, Fabio; Notarnicola, Michele; Carbone, Giuseppe

    2016-11-15

    Micro-scale textured Teflon surfaces, resulting from plasma etching modification, show extremely high water contact angle values and fairly good resistance to water penetration when hit by water drops at medium-high speed. This behavior is more pronounced when these surfaces present denser and smaller micrometric reliefs. Tailoring the top of these reliefs with a structure which further stabilizes the air may further increase resistance to wetting (water penetration) under static and dynamic conditions. Conditions of the oxygen fed plasma were tuned in order to explore the possibility of obtaining differently topped structures on the surface of the polymer. Scanning Electron Microscopy (SEM) was used to explore topography and X-ray Photoelectron Spectroscopy (XPS) to assess chemical similarity of the modified surfaces. Beside the usual advancing and receding water contact angle (WCA) measurements, surfaces were subjected to high speed impacting drops and immersion in water. At milder, i.e. shorter time and lower input power, plasma conditions formation of peculiar filaments is observed on the top of the sculpted reliefs. Filamentary topped surfaces result in a lower WCA than the spherical ones, appearing in this sense less superhydrophobic. However, these surfaces give rise to the formation of a more pronounced air layer when placed underwater. Further, when hit by water drops falling at medium/high speed, they show a higher resistance to water penetration and a sensitively lower surface-liquid contact time. The contact time is as low as previously observed only on heated solids. This behavior may be ascribed to the cavities formed beneath the filaments which, similarly with the salvinia leaf structures, require a surplus of pressure to be filled by water. Also, it suggests a different concept of superhydrophobicity, which cannot be expected on the basis of the conventional water contact angle characterization. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Corneal cell adhesion to contact lens hydrogel materials enhanced via tear film protein deposition.

    Directory of Open Access Journals (Sweden)

    Claire M Elkins

    Full Text Available Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the tear film protein lysozyme. PureVision balafilcon A and AirOptix lotrafilcon B lenses were soaked for five days in either phosphate buffered saline (PBS, borate buffered saline (BBS, or Sensitive Eyes Plus Saline Solution (Sensitive Eyes, either pure or in the presence of lysozyme. Treated contact lenses were then contacted to a live monolayer of corneal epithelial cells for two hours, after which the contact lens was sheared laterally. The apparent cell monolayer relaxation modulus was then used to quantify the extent of cell adhesion to the contact lens surface. For both lens types, lysozyme increased corneal cell adhesion to the contact lens, with the apparent cell monolayer relaxation modulus increasing up to an order of magnitude in the presence of protein. The magnitude of this increase depended on the identity of the soaking solution: lenses soaked in borate-buffered solutions (BBS, Sensitive Eyes exhibited a much greater increase in cell attachment upon protein addition than those soaked in PBS. Significantly, all measurements were conducted while subjecting the cells to moderate surface pressures and shear rates, similar to those experienced by corneal cells in vivo.

  8. Influence of Asymmetric Contact Form on Contact Resistance and Schottky Barrier, and Corresponding Applications of Diode.

    Science.gov (United States)

    Zhao, Yudan; Xiao, Xiaoyang; Huo, Yujia; Wang, Yingcheng; Zhang, Tianfu; Jiang, Kaili; Wang, Jiaping; Fan, Shoushan; Li, Qunqing

    2017-06-07

    We have fabricated carbon nanotube and MoS 2 field-effect transistors with asymmetric contact forms of source-drain electrodes, from which we found the current directionality of the devices and different contact resistances under the two current directions. By designing various structures, we can conclude that the asymmetric electrical performance was caused by the difference in the effective Schottky barrier height (Φ SB ) caused by the different contact forms. A detailed temperature-dependent study was used to extract and compare the Φ SB for both contact forms of CNT and MoS 2 devices; we found that the Φ SB for the metal-on-semiconductor form was much lower than that of the semiconductor-on-metal form and is suitable for all p-type, n-type, or ambipolar semiconductors. This conclusion is meaningful with respect to the design and application of nanomaterial electronic devices. Additionally, using the difference in barrier height caused by the contact forms, we have also proposed and fabricated Schottky barrier diodes with a current ratio up to 10 4 ; rectifying circuits consisting of these diodes were able to work in a wide frequency range. This design avoided the use of complex chemical doping or heterojunction methods to achieve fundamental diodes that are relatively simple and use only a single material; these may be suitable for future application in nanoelectronic radio frequency or integrated circuits.

  9. Occupational irritant contact dermatitis diagnosed by analysis of contact irritants and allergens in the work environment.

    Science.gov (United States)

    Friis, Ulrik F; Menné, Torkil; Schwensen, Jakob F; Flyvholm, Mari-Ann; Bonde, Jens P E; Johansen, Jeanne D

    2014-12-01

    Irritant contact dermatitis (ICD) is a common diagnosis in patients with occupational contact dermatitis (OCD). Studies are lacking on the usefulness of material safety data sheets (MSDSs) in making the diagnosis of ICD. To characterize irritant exposures leading to the diagnosis of occupational ICD (OICD), and to evaluate the occurrence of concomitant exposures to contact allergens. We included 316 patients with suspected occupational hand dermatitis, referred to the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte, Denmark during January 2010-August 2011, in a programme consisting of a clinical examination, exposure assessment, and extensive patch/prick testing. OCD was diagnosed in 228 patients. Of these patients, 118 were diagnosed with OICD. The main irritant exposures identified were wet work (n = 64), gloves (n = 45), mechanical traumas (n = 19), and oils (n = 15). Exposure to specific irritant chemicals was found in 9 patients, and was identified from MSDSs/ingredients labelling in 8 of these patients. Review of MSDSs and ingredients labelling showed that 41 patients were exposed to 41 moderate to potent contact allergens, and 18 patients were exposed to 25 weak workplace contact allergens. In the present study, the systematic exposure assessment did not reveal any new irritants. MSDSs have a limited role in the investigation of ICD. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Proteomic Signatures of the Zebrafish (Danio rerio) Embryo: Sensitivity and Specificity in Toxicity Assessment of Chemicals.

    Science.gov (United States)

    Hanisch, Karen; Küster, Eberhard; Altenburger, Rolf; Gündel, Ulrike

    2010-01-01

    Studies using embryos of the zebrafish Danio rerio (DarT) instead of adult fish for characterising the (eco-) toxic potential of chemicals have been proposed as animal replacing methods. Effect analysis at the molecular level might enhance sensitivity, specificity, and predictive value of the embryonal studies. The present paper aimed to test the potential of toxicoproteomics with zebrafish eleutheroembryos for sensitive and specific toxicity assessment. 2-DE-based toxicoproteomics was performed applying low-dose (EC(10)) exposure for 48 h with three-model substances Rotenone, 4,6-dinitro-o-cresol (DNOC) and Diclofenac. By multivariate "pattern-only" PCA and univariate statistical analyses, alterations in the embryonal proteome were detectable in nonetheless visibly intact organisms and treatment with the three substances was distinguishable at the molecular level. Toxicoproteomics enabled the enhancement of sensitivity and specificity of the embryonal toxicity assay and bear the potency to identify protein markers serving as general stress markers and early diagnosis of toxic stress.

  11. Sensitivity and specificity of the nickel spot (dimethylglyoxime) test.

    Science.gov (United States)

    Thyssen, Jacob P; Skare, Lizbet; Lundgren, Lennart; Menné, Torkil; Johansen, Jeanne D; Maibach, Howard I; Lidén, Carola

    2010-05-01

    The accuracy of the dimethylglyoxime (DMG) nickel spot test has been questioned because of false negative and positive test reactions. The EN 1811, a European standard reference method developed by the European Committee for Standardization (CEN), is fine-tuned to estimate nickel release around the limit value of the EU Nickel Directive from products intended to come into direct and prolonged skin contact. Because assessments according to EN 1811 are expensive to perform, time consuming, and may destruct the test item, it should be of great value to know the accuracy of the DMG screening test. To evaluate the sensitivity and specificity of the DMG test. DMG spot testing, chemical analysis according to the EN 1811 reference method, and X-ray fluorescence spectroscopy (XRF) were performed concomitantly on 96 metallic components from earrings recently purchased in San Francisco. The sensitivity of the DMG test was 59.3% and the specificity was 97.5% based on DMG-test results and nickel release concentrations determined by the EN 1811 reference method. The DMG test has a high specificity but a modest sensitivity. It may serve well for screening purposes. Past exposure studies may have underestimated nickel release from consumer items.

  12. Silicon-Rich Silicon Carbide Hole-Selective Rear Contacts for Crystalline-Silicon-Based Solar Cells.

    Science.gov (United States)

    Nogay, Gizem; Stuckelberger, Josua; Wyss, Philippe; Jeangros, Quentin; Allebé, Christophe; Niquille, Xavier; Debrot, Fabien; Despeisse, Matthieu; Haug, Franz-Josef; Löper, Philipp; Ballif, Christophe

    2016-12-28

    The use of passivating contacts compatible with typical homojunction thermal processes is one of the most promising approaches to realizing high-efficiency silicon solar cells. In this work, we investigate an alternative rear-passivating contact targeting facile implementation to industrial p-type solar cells. The contact structure consists of a chemically grown thin silicon oxide layer, which is capped with a boron-doped silicon-rich silicon carbide [SiC x (p)] layer and then annealed at 800-900 °C. Transmission electron microscopy reveals that the thin chemical oxide layer disappears upon thermal annealing up to 900 °C, leading to degraded surface passivation. We interpret this in terms of a chemical reaction between carbon atoms in the SiC x (p) layer and the adjacent chemical oxide layer. To prevent this reaction, an intrinsic silicon interlayer was introduced between the chemical oxide and the SiC x (p) layer. We show that this intrinsic silicon interlayer is beneficial for surface passivation. Optimized passivation is obtained with a 10-nm-thick intrinsic silicon interlayer, yielding an emitter saturation current density of 17 fA cm -2 on p-type wafers, which translates into an implied open-circuit voltage of 708 mV. The potential of the developed contact at the rear side is further investigated by realizing a proof-of-concept hybrid solar cell, featuring a heterojunction front-side contact made of intrinsic amorphous silicon and phosphorus-doped amorphous silicon. Even though the presented cells are limited by front-side reflection and front-side parasitic absorption, the obtained cell with a V oc of 694.7 mV, a FF of 79.1%, and an efficiency of 20.44% demonstrates the potential of the p + /p-wafer full-side-passivated rear-side scheme shown here.

  13. Evaluation of Doped Phthalocyanines and a Chemically-Sensitive Field Effect Transistor for Detecting Nitrogen Dioxide

    Science.gov (United States)

    1989-12-04

    exposure. Muller, et al., attempted to correct a problem with their simple arrays. With a simple array, each individual detector within the array would be...tna! relates fundamental material and geometrica ! considerations in the development of a chemically-sensitive microsensor based upon the IGEFET. Also...MEASUREMENT 5600 P-RINT * 5650 PRINT "SET-UP THE ELECTROMETER FOR ZERO CORRECT " 5660 INPUT ’ENTER RETURN WHEN READY", M’ULL$ 5700 S$="F1" ’SET 10 MEASURE

  14. Sensitivity of simulated convection-driven stratosphere-troposphere exchange in WRF-Chem to the choice of physical and chemical parameterization

    Science.gov (United States)

    Phoenix, Daniel B.; Homeyer, Cameron R.; Barth, Mary C.

    2017-08-01

    Tropopause-penetrating convection is capable of rapidly transporting air from the lower troposphere to the upper troposphere and lower stratosphere (UTLS), where it can have important impacts on chemistry, the radiative budget, and climate. However, obtaining in situ measurements of convection and convective transport is difficult and such observations are historically rare. Modeling studies, on the other hand, offer the advantage of providing output related to the physical, dynamical, and chemical characteristics of storms and their environments at fine spatial and temporal scales. Since these characteristics of simulated convection depend on the chosen model design, we examine the sensitivity of simulated convective transport to the choice of physical (bulk microphysics or BMP and planetary boundary layer or PBL) and chemical parameterizations in the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem). In particular, we simulate multiple cases where in situ observations are available from the recent (2012) Deep Convective Clouds and Chemistry (DC3) experiment. Model output is evaluated using ground-based radar observations of each storm and in situ trace gas observations from two aircraft operated during the DC3 experiment. Model results show measurable sensitivity of the physical characteristics of a storm and the transport of water vapor and additional trace gases into the UTLS to the choice of BMP. The physical characteristics of the storm and transport of insoluble trace gases are largely insensitive to the choice of PBL scheme and chemical mechanism, though several soluble trace gases (e.g., SO2, CH2O, and HNO3) exhibit some measurable sensitivity.

  15. Sensitivity of chemical vapor deposition diamonds to DD and DT neutrons at OMEGA and the National Ignition Facility

    Science.gov (United States)

    Kabadi, N. V.; Sio, H.; Glebov, V.; Gatu Johnson, M.; MacPhee, A.; Frenje, J. A.; Li, C. K.; Seguin, F.; Petrasso, R.; Forrest, C.; Knauer, J.; Rinderknecht, H. G.

    2016-11-01

    The particle-time-of-flight (pTOF) detector at the National Ignition Facility (NIF) is used routinely to measure nuclear bang-times in inertial confinement fusion implosions. The active detector medium in pTOF is a chemical vapor deposition diamond. Calibration of the detectors sensitivity to neutrons and protons would allow measurement of nuclear bang times and hot spot areal density (ρR) on a single diagnostic. This study utilizes data collected at both NIF and Omega in an attempt to determine pTOF's absolute sensitivity to neutrons. At Omega pTOF's sensitivity to DT-n is found to be stable to within 8% at different bias voltages. At the NIF pTOF's sensitivity to DD-n varies by up to 59%. This variability must be decreased substantially for pTOF to function as a neutron yield detector at the NIF. Some possible causes of this variability are ruled out.

  16. Apparatus for chemical synthesis

    Science.gov (United States)

    Kong, Peter C [Idaho Falls, ID; Herring, J Stephen [Idaho Falls, ID; Grandy, Jon D [Idaho Falls, ID

    2011-05-10

    A method and apparatus for forming a chemical hydride is described and which includes a pseudo-plasma-electrolysis reactor which is operable to receive a solution capable of forming a chemical hydride and which further includes a cathode and a movable anode, and wherein the anode is moved into and out of fluidic, ohmic electrical contact with the solution capable of forming a chemical hydride and which further, when energized produces an oxygen plasma which facilitates the formation of a chemical hydride in the solution.

  17. Sensitive fluorescence on-off probes for the fast detection of a chemical warfare agent mimic.

    Science.gov (United States)

    Khan, Muhammad Shar Jhahan; Wang, Ya-Wen; Senge, Mathias O; Peng, Yu

    2018-01-15

    Two highly sensitive probes bearing a nucleophilic imine moiety have been utilized for the selective detection of chemical warfare agent (CWA) mimics. Diethyl chlorophosphate (DCP) was used as mimic CWAs. Both iminocoumarin-benzothiazole-based probes not only demonstrated a remarkable fluorescence ON-OFF response and good recognition, but also exhibited fast response times (10s) along with color changes upon addition of DCP. Limits of detection for the two sensors 1 and 2 were calculated as 0.065μM and 0.21μM, respectively, which are much lower than most other reported probes. These two probes not only show high sensitivity and selectivity in solution, but can also be applied for the recognition of DCP in the gas state, with significant color changes easily observed by the naked eye. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Gene transcripts as potential diagnostic markers for allergic contact dermatitis

    DEFF Research Database (Denmark)

    Hansen, Malene Barré; Skov, Lone; Menné, Torkil

    2005-01-01

    The standard procedure for diagnosing allergic contact dermatitis is to perform a patch test. Because this has several disadvantages, the development of a new in vitro test system would be of immense value. Gene transcripts that distinguish allergics from non-allergics may have the potential...... widely available. The 26 differentially expressed genes identified in this study may potentially function as diagnostic markers for contact sensitivity....

  19. Microfluidic impact printer with interchangeable cartridges for versatile non-contact multiplexed micropatterning.

    Science.gov (United States)

    Ding, Yuzhe; Huang, Eric; Lam, Kit S; Pan, Tingrui

    2013-05-21

    Biopatterning has been increasingly used for well-defined cellular microenvironment, patterned surface topology, and guided biological cues; however, it meets challenges on biocompatibility, thermal and chemical sensitivity, as well as limited availability of reagents. In this paper, we aim at combining the desired features from non-contact inkjet printing and dot-matrix impact printing to establish a versatile multiplexed micropatterning platform, referred to as Microfluidic Impact Printer (MI-Printer), for emerging biomedical applications. Using this platform, we can achieve the distinct features of no cross-contamination, sub-microliter ink loading with a minimal dead volume, high-throughput printing, biocompatible non-contact processing, sequential patterning with self-alignment, wide adaptability for complex media (e.g., cell suspension or colloidal solutions), interchangeable/disposable cartridge design, and simple assembly and configuration, all highly desirable towards laboratory-based research and development. Specifically, the printing resolution of the MI-printer platform has been experimentally characterized and theoretically analysed. Optimal printing resolution of 80 μm has been repeatedly obtained. Furthermore, two useful functions of the MI-printer, multiplexed printing and combinatorial printing, have been experimentally demonstrated with less than 10 μm misalignment. Moreover, molecular and biological patterning, utilizing the multiplexed and combinatorial printing, has been implemented to illustrate the utility of this versatile printing technique for emerging biomedical applications.

  20. Sensitive Diagnostics for Chemically Reacting Flows

    KAUST Repository

    Farooq, Aamir

    2015-01-01

    This talk will feature latest diagnostic developments for sensitive detection of gas temperature and important combustion species. Advanced optical strategies, such as intrapulse chirping, wavelength modulation, and cavity ringdown are employed.

  1. Sensitive Diagnostics for Chemically Reacting Flows

    KAUST Repository

    Farooq, Aamir

    2015-11-02

    This talk will feature latest diagnostic developments for sensitive detection of gas temperature and important combustion species. Advanced optical strategies, such as intrapulse chirping, wavelength modulation, and cavity ringdown are employed.

  2. Future Needs and Recommendations in the Development of Species Sensitivity Distributions: Estimating Toxicity Thresholds for Aquatic Ecological Communities and Assessing Impacts of Chemical Exposures

    Science.gov (United States)

    A species sensitivity distribution (SSD) is a probability model of the variation of species sensitivities to a stressor, in particular chemical exposure. The SSD approach has been used as a decision support tool in environmental protection and management since the 1980s, and the ...

  3. Quarterly progress report for the Chemical and Energy Research Section of the Chemical Technology Division: July--September 1997

    Energy Technology Data Exchange (ETDEWEB)

    Jubin, R.T.

    1998-07-01

    This report summarizes the major activities conducted in the Chemical and Energy Research Section of the Chemical Technology Division at Oak Ridge National Laboratory (ORNL) during the period July--September 1997. The section conducts basic and applied research and development in chemical engineering, applied chemistry, and bioprocessing, with an emphasis on energy-driven technologies and advanced chemical separations for nuclear and waste applications. The report describes the various tasks performed within nine major areas of research: Hot Cell Operations, Process Chemistry and Thermodynamics, Molten Salt Reactor Experiment (MSRE) Remediation Studies, Chemistry Research, Biotechnology, Separations and Materials Synthesis, Fluid Structure and Properties, Biotechnology Research, and Molecular Studies. The name of a technical contact is included with each task described, and readers are encouraged to contact these individuals if they need additional information.

  4. Diagnosing Allergic Contact Dermatitis Through Elimination, Perception, Detection and Deduction.

    Science.gov (United States)

    Pongpairoj, Korbkarn; Puangpet, Pailin; Thaiwat, Supitchaya; McFadden, John P

    2017-10-01

    Several authors have commented upon the skills of detection required in making a diagnosis of allergic contact dermatitis. Here, we emphasise the search for clues in a systematic manner. We describe four stages as part of a systematic method for diagnosing allergic contact dermatitis. Firstly, elimination (or inclusion) of non-allergic diagnoses. Secondly, perception: the pre-patch test diagnosis and the 'three scenarios' principle. Thirdly, detection: optimising the sensitivity of the patch test process. Fourthly, deduction: diagnosing allergic contact dermatitis by associating the dermatitis with the allergen exposure. We further compare and contrast the pre-patch test history and examination with the markedly different one ('microhistory' and 'microexamination') used after patch testing. The importance of knowledge of contact dermatitis literature is emphasised with a review of recent publications. Finally, we also highlight the use of contact allergy profiling as an investigative tool in the diagnosis of allergic contact dermatitis.

  5. Improved Optical Fiber Chemical Sensors

    Science.gov (United States)

    Egalon, Claudio O.; Rogowski, Robert S.

    1994-01-01

    Calculations, based on exact theory of optical fiber, have shown how to increase optical efficiency sensitivity of active-core, step-index-profile optical-fiber fluorosensor. Calculations result of efforts to improve efficiency of optical-fiber chemical sensor of previous concept described in "Making Optical-Fiber Chemical Sensors More Sensitive" (LAR-14525). Optical fiber chemical detector of enhanced sensitivity made in several configurations. Portion of fluorescence or chemiluminescence generated in core, and launched directly into bound electromagnetic modes that propagate along core to photodetector.

  6. Methyldibromoglutaronitrile in rinse-off products causes allergic contact dermatitis

    DEFF Research Database (Denmark)

    Jensen, C D; Johansen, J D; Menné, T

    2004-01-01

    BACKGROUND: The frequency of sensitivity to the cosmetic preservative methyldibromoglutaronitrile (MDBGN) has increased significantly in Europe. Most cases of allergic contact dermatitis from MDBGN are caused by leave-on cosmetic products. The risk of developing allergic contact dermatitis from...... series of MDBGN to determine their patch test threshold values. RESULTS: Seven presensitized individuals (37%) developed allergic contact dermatitis from the soap containing MDBGN. The mean dose of MDBGN per application was 2.2 micro g cm-2 and the reactions appeared between days 6 and 34. All nine...... rinse-off products has been less studied. OBJECTIVES: To investigate the allergic response elicited in presensitized individuals from exposure to a rinse-off product preserved with the maximum permitted level of MDBGN. METHODS: Nineteen contact allergic individuals and nine controls participated...

  7. Wettability and Contact Time on a Biomimetic Superhydrophobic Surface

    Science.gov (United States)

    Liang, Yunhong; Peng, Jian; Li, Xiujuan; Huang, Jubin; Qiu, Rongxian; Zhang, Zhihui; Ren, Luquan

    2017-01-01

    Inspired by the array microstructure of natural superhydrophobic surfaces (lotus leaf and cicada wing), an array microstructure was successfully constructed by high speed wire electrical discharge machining (HS-WEDM) on the surfaces of a 7075 aluminum alloy without any chemical treatment. The artificial surfaces had a high apparent contact angle of 153° ± 1° with a contact angle hysteresis less than 5° and showed a good superhydrophobic property. Wettability, contact time, and the corresponding superhydrophobic mechanism of artificial superhydrophobic surface were investigated. The results indicated that the micro-scale array microstructure was an important factor for the superhydrophobic surface, while different array microstructures exhibited different effects on the wettability and contact time of the artificial superhydrophobic surface. The length (L), interval (S), and height (H) of the array microstructure are the main influential factors on the wettability and contact time. The order of importance of these factors is H > S > L for increasing the apparent contact angle and reducing the contact time. The method, using HS-WEDM to fabricate superhydrophobic surface, is simple, low-cost, and environmentally friendly and can easily control the wettability and contact time on the artificial surfaces by changing the array microstructure. PMID:28772613

  8. Thin-film chemical sensors based on electron tunneling

    Science.gov (United States)

    Khanna, S. K.; Lambe, J.; Leduc, H. G.; Thakoor, A. P.

    1985-01-01

    The physical mechanisms underlying a novel chemical sensor based on electron tunneling in metal-insulator-metal (MIM) tunnel junctions were studied. Chemical sensors based on electron tunneling were shown to be sensitive to a variety of substances that include iodine, mercury, bismuth, ethylenedibromide, and ethylenedichloride. A sensitivity of 13 parts per billion of iodine dissolved in hexane was demonstrated. The physical mechanisms involved in the chemical sensitivity of these devices were determined to be the chemical alteration of the surface electronic structure of the top metal electrode in the MIM structure. In addition, electroreflectance spectroscopy (ERS) was studied as a complementary surface-sensitive technique. ERS was shown to be sensitive to both iodine and mercury. Electrolyte electroreflectance and solid-state MIM electroreflectance revealed qualitatively the same chemical response. A modified thin-film structure was also studied in which a chemically active layer was introduced at the top Metal-Insulator interface of the MIM devices. Cobalt phthalocyanine was used for the chemically active layer in this study. Devices modified in this way were shown to be sensitive to iodine and nitrogen dioxide. The chemical sensitivity of the modified structure was due to conductance changes in the active layer.

  9. Reduction of teat skin mastitis pathogen loads: differences between strains, dips, and contact times.

    Science.gov (United States)

    Enger, B D; Fox, L K; Gay, J M; Johnson, K A

    2015-02-01

    The purpose of these experiments was to (1) assess differences in mastitis pathogen strain sensitivities to teat disinfectants (teat dips), and (2) determine the optimum time for premilking teat dips to remain in contact with teat skin to reduce pathogen loads on teat skin. Two experiments were conducted using the excised teat model. In experiment 1, the differences in mastitis pathogen strain sensitivities to 4 commercially available dips (dip A: 1% H2O2; dip B: 1% chlorine dioxide; dip C: 1% iodophor; and dip D: 0.5% iodophor) were evaluated. Four strains of 11 common mastitis pathogens (Staphylococcus aureus, Streptococcus agalactiae, Mycoplasma bovis, Streptococcus dysgalactiae, Streptococcus uberis, Escherichia coli, Staphylococcus chromogenes, Staphylococcus epidermidis, Staphylococcus hyicus, Staphylococcus xylosus, and Staphylococcus haemolyticus) were tested. In experiment 2, the percentage log reduction of mastitis pathogens (Escherichia coli, Streptococcus uberis, Streptococcus dysgalactiae, Klebsiella species, Staphylococcus chromogenes, Staphylococcus haemolyticus, Staphylococcus xylosus, and Staphylococcus epidermidis) on teat skin with 3 commercially available teat dips: dip A; dip D; and dip E: 0.25% iodophor, using dip contact times of 15, 30, and 45 s, was evaluated. Experiment 1 results indicated significant differences in strain sensitivities to dips within pathogen species: Staphylococcus aureus, Staphylococcus chromogenes, and Streptococcus uberis. Species differences were also found where Mycoplasma bovis (97.9% log reduction) was the most sensitive to tested teat dips and Staphylococcus haemolyticus (71.4% log reduction) the most resistant. Experiment 2 results indicated that contact times of 30 and 45 s were equally effective in reducing recovered bacteria for dips D and E and were also significantly more effective than a 15-s contact time. No differences were seen in recovered bacteria between tested contact times after treatment with dip

  10. Titanium contacts to graphene: process-induced variability in electronic and thermal transport

    Science.gov (United States)

    Freedy, Keren M.; Giri, Ashutosh; Foley, Brian M.; Barone, Matthew R.; Hopkins, Patrick E.; McDonnell, Stephen

    2018-04-01

    Contact resistance (R C) is a major limiting factor in the performance of graphene devices. R C is sensitive to the quality of the interface and the composition of the contact, which are affected by the graphene transfer process and contact deposition conditions. In this work, a linear correlation is observed between the composition of Ti contacts, characterized by x-ray photoelectron spectroscopy, and the Ti/graphene contact resistance measured by the transfer length method. We find that contact composition is tunable via deposition rate and base pressure. Reactor base pressure is found to effect the resultant contact resistance. The effect of contact deposition conditions on thermal transport measured by time-domain thermoreflectance is also reported. Interfaces with higher oxide composition appear to result in a lower thermal boundary conductance. Possible origins of this thermal boundary conductance change with oxide composition are discussed.

  11. Two-dimensional position sensitive Si(Li) detector

    International Nuclear Information System (INIS)

    Walton, J.T.; Hubbard, G.S.; Haller, E.E.; Sommer, H.A.

    1978-11-01

    Circular, large-area two-dimensional Si(Li) position sensitive detectors have been fabricated. The detectors employ a thin lithium-diffused n + resisitive layer for one contact and a boron implanted p + resistive layer for the second contact. A position resolution of the order of 100 μm is indicated

  12. Effects of pressure and temperature on thermal contact resistance between different materials

    Directory of Open Access Journals (Sweden)

    Zhao Zhe

    2015-01-01

    Full Text Available To explore whether pressure and temperature can affect thermal contact resistance, we have proposed a new experimental approach for measurement of the thermal contact resistance. Taking the thermal contact resistance between phenolic resin and carbon-carbon composites, cuprum, and aluminum as the examples, the influence of the thermal contact resistance between specimens under pressure is tested by experiment. Two groups of experiments are performed and then an analysis on influencing factors of the thermal contact resistance is presented in this paper. The experimental results reveal that the thermal contact resistance depends not only on the thermal conductivity coefficient of materials, but on the interfacial temperature and pressure. Furthermore, the thermal contact resistance between cuprum and aluminum is more sensitive to pressure and temperature than that between phenolic resin and carbon-carbon composites.

  13. A panchromatic anthracene-fused porphyrin sensitizer for dye-sensitized solar cells

    KAUST Repository

    Ball, James M.; Davis, Nicola K. S.; Wilkinson, James D.; Kirkpatrick, James; Teuscher, Joë l; Gunning, Robert; Anderson, Harry L.; Snaith, Henry J.

    2012-01-01

    The development of ruthenium-free sensitizers which absorb light over a broad range of the solar spectrum is important for improving the power conversion efficiency of dye-sensitized solar cells. Here we study three chemically tailored porphyrin

  14. Contact stiffness considerations when simulating tyre/road noise

    Science.gov (United States)

    Winroth, Julia; Kropp, Wolfgang; Hoever, Carsten; Höstmad, Patrik

    2017-11-01

    Tyre/road simulation tools that can capture tyre vibrations, rolling resistance and noise generation are useful for understanding the complex processes that are involved and thereby promoting further development and optimisation. The most detailed tyre/road contact models use a spatial discretisation of the contact and assume an interfacial stiffness to account for the small-scale roughness within the elements. This interfacial stiffness has been found to have a significant impact on the simulated noise emissions but no thorough investigations of this sensitivity have been conducted. Three mechanisms are thought to be involved: The horn effect, the modal composition of the vibrational field of the tyre and the contact forces exciting the tyre vibrations. This study used a numerical tyre/road noise simulation tool based on physical relations to investigate these aspects. The model includes a detailed time-domain contact model with linear or non-linear contact springs that accounts for the effect of local tread deformation on smaller length scales. Results confirm that an increase in contact spring stiffness causes a significant increase of the simulated tyre/road noise. This is primarily caused by a corresponding increase in the contact forces, resulting in larger vibrational amplitudes. The horn effect and the modal composition are relatively unaffected and have minor effects on the radiated noise. A more detailed non-linear contact spring formulation with lower stiffness at small indentations results in a reduced high-frequency content in the contact forces and the simulated noise.

  15. AH Cancri: a contact binary in M67

    International Nuclear Information System (INIS)

    Whelan, J.A.J.; Worden, S.P.; Rucinski, S.M.

    1979-01-01

    The W UMa-type contact binary system AH Cnc, which is a member of the old galactic cluster M67, has been studied spectroscopically and photometrically. Estimates of masses, radii, effective temperature and luminosity of AH Cnc have been derived from these data and from cluster membership considerations. The results suggest that AH Cnc is a typical evolved W-type W UMa contact system, although whether the system has evolved as a contact system or has recently become so, could not be determined. The properties of AH Cnc are similar to those of TX Cnc in Praesepe. Information provided by the existence of a gap in the Hertzsprung-Russell diagram for M67 has been coupled with the AH Cnc results to provide further estimates of the chemical composition of M67. (author)

  16. Nano-indentation at the surface contact level: applying a harmonic frequency for measuring contact stiffness of self-assembled monolayers adsorbed on Au

    International Nuclear Information System (INIS)

    Chang, C.-W.; Liao, J.-D.

    2008-01-01

    In this study, the well-ordered alkanethiolate self-assembled monolayers (SAMs) of varied chain lengths and tail groups were employed as examples for nano-characterization on their mechanical properties. A novel nano-indentation technique with a constant harmonic frequency was applied on SAMs chemically adsorbed on Au to explore their contact mechanics, and furthermore to interpret how SAM molecules respond to an infinitesimal oscillation force without pressing them. Experimental results demonstrated that the harmonic contact stiffness along with the measured displacement of SAMs/Au was distinguishable using a dynamic contact modulus with the distinct feature of phase angles. Phase angles resulted from the relaxing continuation of an applied harmonic frequency and mostly influenced by the outermost tail group of SAM molecules. The harmonic contact stiffness of SAM molecules obviously increased with the densely packed alkyl chains and relatively intense agglomeration of the head group at the anchoring site. As a consequence, the result of this work is relevant to contact mechanics at the surface contact level for the distinction of molecular substances attached on a solid surface. Furthermore it is particularly anticipated to identify biological molecules of variable qualities under a fluid-like micro-environment

  17. Nano-indentation at the surface contact level: applying a harmonic frequency for measuring contact stiffness of self-assembled monolayers adsorbed on Au

    Energy Technology Data Exchange (ETDEWEB)

    Chang, C.-W.; Liao, J.-D. [Department of Materials Science and Engineering, National Cheng Kung University, No. 1, University Road, Tainan 70101, Taiwan (China)], E-mail: jdliao@mail.ncku.edu.tw

    2008-08-06

    In this study, the well-ordered alkanethiolate self-assembled monolayers (SAMs) of varied chain lengths and tail groups were employed as examples for nano-characterization on their mechanical properties. A novel nano-indentation technique with a constant harmonic frequency was applied on SAMs chemically adsorbed on Au to explore their contact mechanics, and furthermore to interpret how SAM molecules respond to an infinitesimal oscillation force without pressing them. Experimental results demonstrated that the harmonic contact stiffness along with the measured displacement of SAMs/Au was distinguishable using a dynamic contact modulus with the distinct feature of phase angles. Phase angles resulted from the relaxing continuation of an applied harmonic frequency and mostly influenced by the outermost tail group of SAM molecules. The harmonic contact stiffness of SAM molecules obviously increased with the densely packed alkyl chains and relatively intense agglomeration of the head group at the anchoring site. As a consequence, the result of this work is relevant to contact mechanics at the surface contact level for the distinction of molecular substances attached on a solid surface. Furthermore it is particularly anticipated to identify biological molecules of variable qualities under a fluid-like micro-environment.

  18. Finite element analysis on the influence of contact resistivity in an extraordinary magnetoresistance magnetic field micro sensor

    KAUST Repository

    Sun, Jian

    2011-08-06

    In this paper, an extraordinary magnetoresistance (EMR) device made of an InSb/Au hybrid structure was investigated. Those devices have a large potential in becoming a new generation of highly sensitive and cheap magnetic micro sensors. A crucial factor for the performance is the interface between the InSb and Au, which suffers from a certain contact resistivity. The Finite Element Method (FEM) was employed to simulate the current redistribution in the device, under an applied magnetic field. Specifically, the influence of the contact resistivity between the InSb bulk and Au shunt was studied. In a device with optimized geometry and without contact resistivity between the layers of InSb and Au, the EMR effect and the sensitivity show values of 1.89 × 104% and 0.02%/(10-4 T), respectively, at 1 Tesla. For values of contact resistivity up to 10-8cm2 the EMR effect is almost constant, while for higher values the EMR effect decreases exponentially. However, the sensitivity of the device does not decrease until 5 × 10-6 cm2 of contact resistivity. Only beyond this value the sensitivity, which in most cases is associated with the performance of the device, will deteriorate. © Springer Science+Business Media, LLC 2011.

  19. Contacting nanowires and nanotubes with atomic precision for electronic transport

    KAUST Repository

    Qin, Shengyong; Hellstrom, Sondra; Bao, Zhenan; Boyanov, Boyan; Li, An-Ping

    2012-01-01

    Making contacts to nanostructures with atomic precision is an important process in the bottom-up fabrication and characterization of electronic nanodevices. Existing contacting techniques use top-down lithography and chemical etching, but lack atomic precision and introduce the possibility of contamination. Here, we report that a field-induced emission process can be used to make local contacts onto individual nanowires and nanotubes with atomic spatial precision. The gold nano-islands are deposited onto nanostructures precisely by using a scanning tunneling microscope tip, which provides a clean and controllable method to ensure both electrically conductive and mechanically reliable contacts. To demonstrate the wide applicability of the technique, nano-contacts are fabricated on silicide atomic wires, carbon nanotubes, and copper nanowires. The electrical transport measurements are performed in situ by utilizing the nanocontacts to bridge the nanostructures to the transport probes. © 2012 American Institute of Physics.

  20. Atom interaction propensities of oxygenated chemical functions in crystal packings

    Directory of Open Access Journals (Sweden)

    Christian Jelsch

    2017-03-01

    Full Text Available The crystal contacts of several families of hydrocarbon compounds substituted with one or several types of oxygenated chemical groups were analyzed statistically using the Hirshfeld surface methodology. The propensity of contacts to occur between two chemical types is described with the contact enrichment descriptor. The systematic large enrichment ratios of some interactions like the O—H...O hydrogen bonds suggests that these contacts are a driving force in the crystal packing formation. The same statement holds for the weaker C—H...O hydrogen bonds in ethers, esters and ketones, in the absence of polar H atoms. The over-represented contacts in crystals of oxygenated hydrocarbons are generally of two types: electrostatic attractions (hydrogen bonds and hydrophobic interactions. While Cl...O interactions are generally avoided, in a minority of chloro-oxygenated hydrocarbons, significant halogen bonding does occur. General tendencies can often be derived for many contact types, but outlier compounds are instructive as they display peculiar or rare features. The methodology also allows the detection of outliers which can be structures with errors. For instance, a significant number of hydroxylated molecules displaying over-represented non-favorable oxygen–oxygen contacts turned out to have wrongly oriented hydroxyl groups. Beyond crystal packings with a single molecule in the asymmetric unit, the behavior of water in monohydrate compounds and of crystals with Z′ = 2 (dimers are also investigated. It was found in several cases that, in the presence of several oxygenated chemical groups, cross-interactions between different chemical groups (e.g. water/alcohols; alcohols/phenols are often favored in the crystal packings. While some trends in accordance with common chemical principles are retrieved, some unexpected results can however appear. For example, in crystals of alcohol–phenol compounds, the strong O—H...O hydrogen bonds between

  1. Analysis of air-, moisture- and solvent-sensitive chemical compounds by mass spectrometry using an inert atmospheric pressure solids analysis probe.

    Science.gov (United States)

    Mosely, Jackie A; Stokes, Peter; Parker, David; Dyer, Philip W; Messinis, Antonis M

    2018-02-01

    A novel method has been developed that enables chemical compounds to be transferred from an inert atmosphere glove box and into the atmospheric pressure ion source of a mass spectrometer whilst retaining a controlled chemical environment. This innovative method is simple and cheap to implement on some commercially available mass spectrometers. We have termed this approach inert atmospheric pressure solids analysis probe ( iASAP) and demonstrate the benefit of this methodology for two air-/moisture-sensitive chemical compounds whose characterisation by mass spectrometry is now possible and easily achieved. The simplicity of the design means that moving between iASAP and standard ASAP is straightforward and quick, providing a highly flexible platform with rapid sample turnaround.

  2. Preservatives as important etiologic factors of allergic contact dermatitis

    Directory of Open Access Journals (Sweden)

    Beata Kręcisz

    2015-07-01

    Full Text Available Background: Preservatives present in cosmetics and other industrial products can cause allergic contact dermatitis. The aim of the study was to assess the frequency of allergy to selected preservatives in consecutive patients examined due to contact dermatitis in the Nofer Institute of Occupational Medicine, Łódź, and to establish whether individuals sensitized to formaldehyde react simultaneously to formaldehyde releasers. Material and Methods: A group of 405 patients (308 females and 97 males was examined in 2011–2013. In all participants patch tests with a series of 13 preservatives (paraben mix, formaldehyde, Quaternium 15, chloromethylisothiazolinone/methylisothiazolinone mix, methyldibromoglutaronitrile, diazolidinyl urea, imidazolidinyl urea, DMDM hydantoin, 2-bromo-2-nitropropane-1,3-diol, iodopropynyl butylcarbamate, benzalkonium chloride, sodium metabisulfite, produced by Chemotechnique Diagnostics, Sweden were performed. Results: Of the 405 patients 74 (including 52 females showed positive results of patch tests. Contact allergy to at least 1 preservative was noted in 47 (11.6% patients, including 34 (11% females and 13 (13.4% males. Methylisothiazolinone proved to be the most frequent sensitizer – 4.7% (5.2% females, 3.1% males while parabens, 2-bromo-2-nitropropane-1,3-diol and imidazolidinyl urea (0.2% were found to be the least frequent. Fourteen (3.4% participants, 10 women and 4 men, were allergic to formaldehyde and/or formaldehyde releasers. In 11 (78.6% of them monovalent hypersensitivity was observed. In 13 (3.2% of the examined group patients allergy to preservatives might have been of occupational origin. Conclusions: Preservatives, particularly isothiazolinones, are significant causal factors of allergic contact dermatitis, including occupational cases. Individuals sensitized to formaldehyde may react simultaneously to formaldehyde releasers, however, such reactions are relatively rare. Med Pr 2015;66(3:327–332

  3. Occupational contact urticaria and protein contact dermatitis.

    Science.gov (United States)

    Doutre, Marie-Sylvie

    2005-01-01

    Irritant dermatitis and eczema are the most prevalent occupational skin diseases. Less common are immediate contact reactions such as contact urticaria and protein contact dermatitis. Occupational contact urticaria can be subdivided into two categories, immunological and non immunological. However, some agents can induce these two types of reactions. Contact urticaria to natural rubber latex is particularly frequent among health care personnel, but contact urticaria to a wide variety of other substances occurs in many other occupations. Among those at risk are cooks, bakers, butchers, restaurant personnel, veterinarians, hairdressers, florists, gardeners, and forestry workers. Protein contact dermatitis in some of these occupations is caused principally by proteins of animal or plant origin, especially among individuals with a history of atopic dermatitis. Diagnosis requires careful interrogation, clinical examination and skin tests (open tests and prick tests with immediate lecture) to identify a particular contact allergen.

  4. Sensing with Superconducting Point Contacts

    Directory of Open Access Journals (Sweden)

    Argo Nurbawono

    2012-05-01

    Full Text Available Superconducting point contacts have been used for measuring magnetic polarizations, identifying magnetic impurities, electronic structures, and even the vibrational modes of small molecules. Due to intrinsically small energy scale in the subgap structures of the supercurrent determined by the size of the superconducting energy gap, superconductors provide ultrahigh sensitivities for high resolution spectroscopies. The so-called Andreev reflection process between normal metal and superconductor carries complex and rich information which can be utilized as powerful sensor when fully exploited. In this review, we would discuss recent experimental and theoretical developments in the supercurrent transport through superconducting point contacts and their relevance to sensing applications, and we would highlight their current issues and potentials. A true utilization of the method based on Andreev reflection analysis opens up possibilities for a new class of ultrasensitive sensors.

  5. Sensitive and comprehensive detection of chemical warfare agents in air by atmospheric pressure chemical ionization ion trap tandem mass spectrometry with counterflow introduction.

    Science.gov (United States)

    Seto, Yasuo; Sekiguchi, Hiroshi; Maruko, Hisashi; Yamashiro, Shigeharu; Sano, Yasuhiro; Takayama, Yasuo; Sekioka, Ryoji; Yamaguchi, Shintaro; Kishi, Shintaro; Satoh, Takafumi; Sekiguchi, Hiroyuki; Iura, Kazumitsu; Nagashima, Hisayuki; Nagoya, Tomoki; Tsuge, Kouichiro; Ohsawa, Isaac; Okumura, Akihiko; Takada, Yasuaki; Ezawa, Naoya; Watanabe, Susumu; Hashimoto, Hiroaki

    2014-05-06

    A highly sensitive and specific real-time field-deployable detection technology, based on counterflow air introduction atmospheric pressure chemical ionization, has been developed for a wide range of chemical warfare agents (CWAs) comprising gaseous (two blood agents, three choking agents), volatile (six nerve gases and one precursor agent, five blister agents), and nonvolatile (three lachrymators, three vomiting agents) agents in air. The approach can afford effective chemical ionization, in both positive and negative ion modes, for ion trap multiple-stage mass spectrometry (MS(n)). The volatile and nonvolatile CWAs tested provided characteristic ions, which were fragmented into MS(3) product ions in positive and negative ion modes. Portions of the fragment ions were assigned by laboratory hybrid mass spectrometry (MS) composed of linear ion trap and high-resolution mass spectrometers. Gaseous agents were detected by MS or MS(2) in negative ion mode. The limits of detection for a 1 s measurement were typically at or below the microgram per cubic meter level except for chloropicrin (submilligram per cubic meter). Matrix effects by gasoline vapor resulted in minimal false-positive signals for all the CWAs and some signal suppression in the case of mustard gas. The moisture level did influence the measurement of the CWAs.

  6. Changes in mechanical, chemical, and thermal sensitivity of the cornea after topical application of nonsteroidal anti-inflammatory drugs.

    Science.gov (United States)

    Acosta, M Carmen; Berenguer-Ruiz, Leticia; García-Gálvez, Alberto; Perea-Tortosa, David; Gallar, Juana; Belmonte, Carlos

    2005-01-01

    In addition to their well-known anti-inflammatory actions, some of the nonsteroidal anti-inflammatory drugs (NSAIDs) appear to have an analgesic effect. In human subjects, the changes in threshold and intensity of sensations evoked by mechanical, chemical, and thermal stimulation of the cornea induced by topical administration of two commercial NSAIDs, diclofenac sodium (Voltaren; Novartis, Basel, Switzerland) and flurbiprofen (Ocuflur; Allergan, Irvine, CA), were studied. Corneal sensitivity was measured in 10 young, healthy subjects with a gas esthesiometer. Chemical (10%-70% CO2 in air), mechanical (0-264 mL/min), and thermal (corneal temperature changes between -4.5 degrees C and +3 degrees C around the normal value) stimuli were applied to the center of the cornea. The intensity and perceived magnitude of the psychophysical attributes of the evoked sensation were scored at the end of the pulse in a 10-cm, continuous visual analog scale (VAS). The threshold was expressed as the stimulus intensity that evoked a VAS score >0.5. Sensitivity was measured in both eyes of each subject on two separate days, one without treatment and the other 30 minutes after topical application of 0.03% flurbiprofen (seven subjects) or 0.1% diclofenac sodium (six subjects). Diclofenac attenuated significantly all the sensation parameters evoked by high-intensity mechanical, chemical, and thermal stimuli. Flurbiprofen produced a slight reduction of the sensations evoked by mechanical and chemical stimulation that became significant only for the irritation caused by chemical stimuli of maximum intensity (70% CO2). None of the drugs modified significantly the detection threshold of the different stimuli. Flurbiprofen had a very limited effect on sensations evoked by corneal stimulation, whereas diclofenac reduced the intensity of sensations evoked by stimuli of different modality, suggesting a mild local anesthetic effect of this drug on all types of corneal sensory fibers. Such

  7. Measurement of contact-angle hysteresis for droplets on nanopillared surface and in the Cassie and Wenzel states: a molecular dynamics simulation study.

    Science.gov (United States)

    Koishi, Takahiro; Yasuoka, Kenji; Fujikawa, Shigenori; Zeng, Xiao Cheng

    2011-09-27

    We perform large-scale molecular dynamics simulations to measure the contact-angle hysteresis for a nanodroplet of water placed on a nanopillared surface. The water droplet can be in either the Cassie state (droplet being on top of the nanopillared surface) or the Wenzel state (droplet being in contact with the bottom of nanopillar grooves). To measure the contact-angle hysteresis in a quantitative fashion, the molecular dynamics simulation is designed such that the number of water molecules in the droplets can be systematically varied, but the number of base nanopillars that are in direct contact with the droplets is fixed. We find that the contact-angle hysteresis for the droplet in the Cassie state is weaker than that in the Wenzel state. This conclusion is consistent with the experimental observation. We also test a different definition of the contact-angle hysteresis, which can be extended to estimate hysteresis between the Cassie and Wenzel state. The idea is motivated from the appearance of the hysteresis loop typically seen in computer simulation of the first-order phase transition, which stems from the metastability of a system in different thermodynamic states. Since the initial shape of the droplet can be controlled arbitrarily in the computer simulation, the number of base nanopillars that are in contact with the droplet can be controlled as well. We show that the measured contact-angle hysteresis according to the second definition is indeed very sensitive to the initial shape of the droplet. Nevertheless, the contact-angle hystereses measured based on the conventional and new definition seem converging in the large droplet limit. © 2011 American Chemical Society

  8. Contact allergy in children with and without atopic dermatitis; which are the frequent allergens?

    NARCIS (Netherlands)

    Lubbes, S.; Rustemeyer, T.; Schuttelaar, M.L.A.; Sillevis Smitt, J.H.; Middelkamp-Hup, M.A.

    2014-01-01

    Background: Data on contact allergies in children are conflicting. This study aims to identify frequent contact allergens and their relevance in children with and without atopic dermatitis (AD). This will allow better identification of potential sensitizers and improve patients' care in children.

  9. Allergic Contact Dermatitis to Ophthalmic Medications: Relevant Allergens and Alternative Testing Methods.

    Science.gov (United States)

    Grey, Katherine R; Warshaw, Erin M

    Allergic contact dermatitis is an important cause of periorbital dermatitis. Topical ophthalmic agents are relevant sensitizers. Contact dermatitis to ophthalmic medications can be challenging to diagnose and manage given the numerous possible offending agents, including both active and inactive ingredients. Furthermore, a substantial body of literature reports false-negative patch test results to ophthalmic agents. Subsequently, numerous alternative testing methods have been described. This review outlines the periorbital manifestations, causative agents, and alternative testing methods of allergic contact dermatitis to ophthalmic medications.

  10. Design and application of ion-implanted polySi passivating contacts for interdigitated back contact c-Si solar cells

    International Nuclear Information System (INIS)

    Yang, Guangtao; Ingenito, Andrea; Hameren, Nienke van; Isabella, Olindo; Zeman, Miro

    2016-01-01

    Ion-implanted passivating contacts based on poly-crystalline silicon (polySi) are enabled by tunneling oxide, optimized, and used to fabricate interdigitated back contact (IBC) solar cells. Both n-type (phosphorous doped) and p-type (boron doped) passivating contacts are fabricated by ion-implantation of intrinsic polySi layers deposited via low-pressure chemical vapor deposition and subsequently annealed. The impact of doping profile on the passivation quality of the polySi doped contacts is studied for both polarities. It was found that an excellent surface passivation could be obtained by confining as much as possible the implanted-and-activated dopants within the polySi layers. The doping profile in the polySi was controlled by modifying the polySi thickness, the energy and dose of ion-implantation, and the temperature and time of annealing. An implied open-circuit voltage of 721 mV for n-type and 692 mV for p-type passivating contacts was achieved. Besides the high passivating quality, the developed passivating contacts exhibit reasonable high conductivity (R sh n-type  = 95 Ω/□ and R sh p-type  = 120 Ω/□). An efficiency of 19.2% (V oc  = 673 mV, J sc  = 38.0 mA/cm 2 , FF = 75.2%, and pseudo-FF = 83.2%) was achieved on a front-textured IBC solar cell with polySi passivating contacts as both back surface field and emitter. By improving the front-side passivation, a V OC of 696 mV was also measured

  11. Highly sensitive methanol chemical sensor based on undoped silver oxide nanoparticles prepared by a solution method

    International Nuclear Information System (INIS)

    Rahman, M.M.; Khan, S.B.; Asiri, A.M.; Jamal, A.; Faisal, M.

    2012-01-01

    We have prepared silver oxide nanoparticles (NPs) by a simple solution method using reducing agents in alkaline medium. The resulting NPs were characterized by UV-vis and FT-IR spectroscopy, X-ray powder diffraction, and field-emission scanning electron microscopy. They were deposited on a glassy carbon electrode to give a sensor with a fast response towards methanol in liquid phase. The sensor also displays good sensitivity and long-term stability, and enhanced electrochemical response. The calibration plot is linear (r 2 = 0.8294) over the 0.12 mM to 0.12 M methanol concentration range. The sensitivity is ∼ 2.65 μAcm -2 mM -1 , and the detection limit is 36.0 μM (at a SNR of 3). We also discuss possible future prospective uses of this metal oxide semiconductor nanomaterial in terms of chemical sensing. (author)

  12. Sensitivity of men and women to effect of chemical factors

    Energy Technology Data Exchange (ETDEWEB)

    Aliyev, V.A.

    1985-05-01

    The activity of enzymes performing energy metabolism and electron transport in the respiratory chain and anabolism and catabolism processes in cells of the blood system of men and women petroleum processing workers is described and discussed. Enzymic activity was studied by cytochemical methods. Subjects included basic petroleum processing device operators (96 women and 74 men ranging in age from 19-30 years with work experience ranging from 4 months to 10 years). The control group included 133 persons of corresponding age-sex groups who were not involved in petroleum processing work. The cytoenzymic studies refuted the assumption that women workers are more sensitive than men workers to the effect of toxic substances. On the whole, the men in the study were found to be less resistant to the effect of chemical factors encountered in petroleum processing work. It was assumed that specific features of functioning of the female body (menstruation, pregnancy and birth), causing stress and reconstruction of homeostasis systems, promoted improvement of adaptational mechanisms in the process of evolution, which mechanisms were coded in the gene pool. It is speculated that sexual differences may cause differences in cell metabolism. 12 refs.

  13. Fast, sensitive, and selective gas chromatography tandem mass spectrometry method for the target analysis of chemical secretions from femoral glands in lizards.

    Science.gov (United States)

    Sáiz, Jorge; García-Roa, Roberto; Martín, José; Gómara, Belén

    2017-09-08

    Chemical signaling is a widespread mode of communication among living organisms that is used to establish social organization, territoriality and/or for mate choice. In lizards, femoral and precloacal glands are important sources of chemical signals. These glands protrude chemical secretions used to mark territories and also, to provide valuable information from the bearer to other individuals. Ecologists have studied these chemical secretions for decades in order to increase the knowledge of chemical communication in lizards. Although several studies have focused on the chemical analysis of these secretions, there is a lack of faster, more sensitive and more selective analytical methodologies for their study. In this work a new GC coupled to tandem triple quadrupole MS (GC-QqQ (MS/MS)) methodology is developed and proposed for the target study of 12 relevant compounds often found in lizard secretions (i.e. 1-hexadecanol, palmitic acid, 1-octadecanol, oleic acid, stearic acid, 1-tetracosanol, squalene, cholesta-3,5-diene, α-tocopherol, cholesterol, ergosterol and campesterol). The method baseline-separated the analytes in less than 7min, with instrumental limits of detection ranging from 0.04 to 6.0ng/mL. It was possible to identify differences in the composition of the samples from the lizards analyzed, which depended on the species, the habitat occupied and the diet of the individuals. Moreover, α-tocopherol has been determined for the first time in a lizard species, which was thought to lack its expression in chemical secretions. Globally, the methodology has been proven to be a valuable alternative to other published methods with important improvements in terms of analysis time, sensitivity, and selectivity. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Comparative sensitizing potencies of fragrances, preservatives, and hair dyes

    DEFF Research Database (Denmark)

    Lidén, Carola; Yazar, Kerem; Johansen, Jeanne Duus

    2016-01-01

    the sensitizing potencies of fragrance substances, preservatives, and hair dye substances, which are skin sensitizers that frequently come into contact with the skin of consumers and workers, LLNA results and EC3 values for 72 fragrance substances, 25 preservatives and 107 hair dye substances were obtained from...... two published compilations of LLNA data and opinions by the Scientific Committee on Consumer Safety and its predecessors. The median EC3 values of fragrances (n = 61), preservatives (n = 19) and hair dyes (n = 59) were 5.9%, 0.9%, and 1.3%, respectively. The majority of sensitizing preservatives...... and hair dyes are thus strong or extreme sensitizers (EC3 value of ≤2%), and fragrances are mostly moderate sensitizers. Although fragrances are typically moderate sensitizers, they are among the most frequent causes of contact allergy. This indicates that factors other than potency need to be addressed...

  15. Segmentation of the Outer Contact on P-Type Coaxial Germanium Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hull, Ethan L.; Pehl, Richard H.; Lathrop, James R.; Martin, Gregory N.; Mashburn, R. B.; Miley, Harry S.; Aalseth, Craig E.; Hossbach, Todd W.

    2006-09-21

    Germanium detector arrays are needed for low-level counting facilities. The practical applications of such user facilities include characterization of low-level radioactive samples. In addition, the same detector arrays can also perform important fundamental physics measurements including the search for rare events like neutrino-less double-beta decay. Coaxial germanium detectors having segmented outer contacts will provide the next level of sensitivity improvement in low background measurements. The segmented outer detector contact allows performance of advanced pulse shape analysis measurements that provide additional background reduction. Currently, n-type (reverse electrode) germanium coaxial detectors are used whenever a segmented coaxial detector is needed because the outer boron (electron barrier) contact is thin and can be segmented. Coaxial detectors fabricated from p-type germanium cost less, have better resolution, and are larger than n-type coaxial detectors. However, it is difficult to reliably segment p-type coaxial detectors because thick (~1 mm) lithium-diffused (hole barrier) contacts are the standard outside contact for p-type coaxial detectors. During this Phase 1 Small Business Innovation Research (SBIR) we have researched the possibility of using amorphous germanium contacts as a thin outer contact of p-type coaxial detectors that can be segmented. We have developed amorphous germanium contacts that provide a very high hole barrier on small planar detectors. These easily segmented amorphous germanium contacts have been demonstrated to withstand several thousand volts/cm electric fields with no measurable leakage current (<1 pA) from charge injection over the hole barrier. We have also demonstrated that the contact can be sputter deposited around and over the curved outside surface of a small p-type coaxial detector. The amorphous contact has shown good rectification properties on the outside of a small p-type coaxial detector. These encouraging

  16. Ethosome formulations of known contact allergens can increase their sensitizing capacity

    DEFF Research Database (Denmark)

    Madsen, Jacob Torp; Vogel, Stefan; Karlberg, Ann-Therese

    2010-01-01

    a modified local lymph node assay (LLNA). The results were compared with those for the same allergens in similar concentrations and vehicles without ethosomes. Both allergens encapsulated in 200-300 nm ethosomes showed increased sensitizing potency in the murine assay compared with the allergens in solution...... without ethosomes. Empty ethosomes were non-sensitizing according to LLNA. The clinical implications are so far uncertain, but increased allergenicity from ethosome-encapsulated topical product ingredients cannot be excluded....

  17. Resistance of Pseudomonas aeruginosa isolates to hydrogel contact lens disinfection correlates with cytotoxic activity.

    Science.gov (United States)

    Lakkis, C; Fleiszig, S M

    2001-04-01

    One of the most common pathogens in infection of hydrogel contact lens wearers is Pseudomonas aeruginosa, which can gain access to the eye via contamination of the lens, lens case, and lens care solutions. Only one strain per species is used in current regulatory testing for the marketing of chemical contact lens disinfectants. The aim of this study was to determine whether P. aeruginosa strains vary in their susceptibility to hydrogel contact lens disinfectants. A method for rapidly screening bacterial susceptibility to contact lens disinfectants was developed, based on measurement of the MIC. The susceptibility of 35 P. aeruginosa isolates to two chemical disinfectants was found to vary among strains. MICs ranged from 6.25 to 100% for both disinfectants at 37 degrees C, and a number of strains were not inhibited by a 100% disinfectant concentration in the lens case environment at room temperature (22 degrees C). Resistance to disinfection appeared to be an inherent rather than acquired trait, since some resistant strains had been isolated prior to the introduction of the disinfectants and some susceptible P. aeruginosa strains could not be made more resistant by repeated disinfectant exposure. A number of P. aeruginosa strains which were comparatively more resistant to short-term disinfectant exposure also demonstrated the ability to grow to levels above the initial inoculum in one chemical disinfectant after long-term (24 to 48 h) disinfectant exposure. Resistance was correlated with acute cytotoxic activity toward corneal epithelial cells and with exsA, which encodes a protein that regulates cytotoxicity via a complex type III secretion system. These results suggest that chemical disinfection solutions may select for contamination with cytotoxic strains. Further investigation of the mechanisms and factors responsible for resistance may also lead to strategies for reducing adverse responses to contact lens wear.

  18. Factors influencing bacterial adhesion to contact lenses.

    Science.gov (United States)

    Dutta, Debarun; Cole, Nerida; Willcox, Mark

    2012-01-01

    The process of any contact lens related keratitis generally starts with the adhesion of opportunistic pathogens to contact lens surface. This article focuses on identifying the factors which have been reported to affect bacterial adhesion to contact lenses. Adhesion to lenses differs between various genera/species/strains of bacteria. Pseudomonas aeruginosa, which is the predominant causative organism, adheres in the highest numbers to both hydrogel and silicone hydrogel lenses in vitro. The adhesion of this strain reaches maximum numbers within 1h in most in vitro studies and a biofilm has generally formed within 24 h of cells adhering to the lens surface. Physical and chemical properties of contact lens material affect bacterial adhesion. The water content of hydroxyethylmethacrylate (HEMA)-based lenses and their iconicity affect the ability of bacteria to adhere. The higher hydrophobicity of silicone hydrogel lenses compared to HEMA-based lenses has been implicated in the higher numbers of bacteria that can adhere to their surfaces. Lens wear has different effects on bacterial adhesion, partly due to differences between wearers, responses of bacterial strains and the ability of certain tear film proteins when bound to a lens surface to kill certain types of bacteria.

  19. Laboratory measurements and model sensitivity studies of dust deposition ice nucleation

    Directory of Open Access Journals (Sweden)

    G. Kulkarni

    2012-08-01

    Full Text Available We investigated the ice nucleating properties of mineral dust particles to understand the sensitivity of simulated cloud properties to two different representations of contact angle in the Classical Nucleation Theory (CNT. These contact angle representations are based on two sets of laboratory deposition ice nucleation measurements: Arizona Test Dust (ATD particles of 100, 300 and 500 nm sizes were tested at three different temperatures (−25, −30 and −35 °C, and 400 nm ATD and kaolinite dust species were tested at two different temperatures (−30 and −35 °C. These measurements were used to derive the onset relative humidity with respect to ice (RHice required to activate 1% of dust particles as ice nuclei, from which the onset single contact angles were then calculated based on CNT. For the probability density function (PDF representation, parameters of the log-normal contact angle distribution were determined by fitting CNT-predicted activated fraction to the measurements at different RHice. Results show that onset single contact angles vary from ~18 to 24 degrees, while the PDF parameters are sensitive to the measurement conditions (i.e. temperature and dust size. Cloud modeling simulations were performed to understand the sensitivity of cloud properties (i.e. ice number concentration, ice water content, and cloud initiation times to the representation of contact angle and PDF distribution parameters. The model simulations show that cloud properties are sensitive to onset single contact angles and PDF distribution parameters. The comparison of our experimental results with other studies shows that under similar measurement conditions the onset single contact angles are consistent within ±2.0 degrees, while our derived PDF parameters have larger discrepancies.

  20. In-Doped ZnO Hexagonal Stepped Nanorods and Nanodisks as Potential Scaffold for Highly-Sensitive Phenyl Hydrazine Chemical Sensors.

    Science.gov (United States)

    Umar, Ahmad; Kim, Sang Hoon; Kumar, Rajesh; Al-Assiri, Mohammad S; Al-Salami, A E; Ibrahim, Ahmed A; Baskoutas, Sotirios

    2017-11-21

    Herein, we report the growth of In-doped ZnO (IZO) nanomaterials, i.e., stepped hexagonal nanorods and nanodisks by the thermal evaporation process using metallic zinc and indium powders in the presence of oxygen. The as-grown IZO nanomaterials were investigated by several techniques in order to examine their morphological, structural, compositional and optical properties. The detailed investigations confirmed that the grown nanomaterials, i.e., nanorods and nanodisks possess well-crystallinity with wurtzite hexagonal phase and grown in high density. The room-temperature PL spectra exhibited a suppressed UV emissions with strong green emissions for both In-doped ZnO nanomaterials, i.e., nanorods and nanodisks. From an application point of view, the grown IZO nanomaterials were used as a potential scaffold to fabricate sensitive phenyl hydrazine chemical sensors based on the I-V technique. The observed sensitivities of the fabricated sensors based on IZO nanorods and nanodisks were 70.43 μA·mM -1 cm -2 and 130.18 μA·mM -1 cm -2 , respectively. For both the fabricated sensors, the experimental detection limit was 0.5 μM, while the linear range was 0.5 μM-5.0 mM. The observed results revealed that the simply grown IZO nanomaterials could efficiently be used to fabricate highly sensitive chemical sensors.